  1. Optical quality of toric intraocular lens implantation in cataract surgery

    Directory of Open Access Journals (Sweden)

    Xian-Wen Xiao

    2015-02-01

    Full Text Available AIM: To analyze the optical quality after implantation of toric intraocular lens with optical quality analysis system. METHODS: Fifty-two eyes of forty-four patients with regular corneal astigmatism of at least 1.00 D underwent implantation of AcrySof toric intraocular lens, including T3 group 19 eyes, T4 group 18 eyes, T5 group 10 eyes, T6 group 5 eyes. Main outcomes evaluated at 3mo of follow-up, included uncorrected distance visual acuity (UDVA, corrected distance visual acuity (CDVA, residual refractive cylinder and intraocular lens (IOL axis rotation. Objective optical quality were measured using optical quality analysis system (OQAS Ⅱ®, Visiometrics, Spain, included the cutoff frequency of modulation transfer function (MTFcutoff, objective scattering index (OSI, Strehl ratio, optical quality analysis system value (OV 100%, OV 20% and OV 9% [the optical quality analysis system (OQAS values at contrasts of 100%, 20%, and 9%]. RESULTS: At 3mo postoperative, the mean UDVA and CDVA was 0.18±0.11 and 0.07±0.08 logMAR; the mean residual refractive cylinder was 0.50±0.29 D; the mean toric IOL axis rotation was 3.62±1.76 degrees, the mean MTFcutoff, OSI, Strehl ratio, OV 100%, OV 20% and OV 9% were 22.862±5.584, 1.80±0.84, 0.155±0.038, 0.76±0.18, 0.77±0.19 and 0.78±0.21. The values of UDVA, CDVA, IOL axis rotation, MTFcutoff, OSI, Strehl ratio, OV100%, OV20% and OV9% depending on the power of the cylinder of the implantation were not significantly different (P>0.05, except the residual refractive cylinder (PCONCLUSION: The optical quality analysis system was useful for characterizing the optical quality of AcrySof toric IOL implantation. Implantation of an AcrySof toric IOL is an effective and safe method to correct corneal astigmatism during cataract surgery.

  2. Optical quality for keratoconic eyes with conventional RGP lens and simulated, customised contact lens corrections: a comparison.

    Science.gov (United States)

    Jinabhai, Amit; Neil Charman, W; O'Donnell, Clare; Radhakrishnan, Hema

    2012-05-01

    To compare monochromatic aberrations of keratoconic eyes when uncorrected, corrected with spherically-powered RGP (rigid gas-permeable) contact lenses and corrected using simulations of customised soft contact lenses for different magnitudes of rotation (up to 15°) and translation (up to 1mm) from their ideal position. The ocular aberrations of examples of mild, moderate and severe keratoconic eyes were measured when uncorrected and when wearing their habitual RGP lenses. Residual aberrations and point-spread functions of each eye were simulated using an ideal, customised soft contact lens (designed to neutralise higher-order aberrations, HOA) were calculated as a function of the angle of rotation of the lens from its ideal orientation, and its horizontal and vertical translation. In agreement with the results of other authors, the RGP lenses markedly reduced both lower-order aberrations and HOA for all three patients. When compared with the RGP lens corrections, the customised lens simulations only provided optical improvements if their movements were constrained within limits which appear to be difficult to achieve with current technologies. At the present time, customised contact lens corrections appear likely to offer, at best, only minor optical improvements over RGP lenses for patients with keratoconus. If made in soft materials, however, these lenses may be preferred by patients in term of comfort. Ophthalmic & Physiological Optics © 2012 The College of Optometrists.

  3. Hydrophilic intraocular lens opacification after posterior lamellar keratoplasty - a material analysis with special reference to optical quality assessment.

    Science.gov (United States)

    Giers, Bert C; Tandogan, Tamer; Auffarth, Gerd U; Choi, Chul Y; Auerbach, Florian N; Sel, Saadettin; Mayer, Christian; Khoramnia, Ramin

    2017-08-22

    Laboratory analysis and optical quality assessment of explanted hydrophilic intraocular lenses (IOLs) with clinically significant opacification after posterior lamellar keratoplasty (DMEK and DSAEK). Thirteen opacified IOLs after posterior lamellar keratoplasty, 8 after descemet stripping automated endothelial keratoplasty (DSAEK), 3 after descemet membrane endothelial keratoplasty (DMEK) and 2 after both DSAEK and DMEK were analysed in our laboratory. Analyses included optical bench assessment for optical quality, light microscopy, scanning electron microscopy (SEM) and energy dispersive X-Ray spectroscopy (EDS). In all IOLs the opacification was caused by a thin layer of calciumphosphate that had accumulated underneath the anterior optical surface of the IOLs in the area spared by the pupil/anterior capsulorhexis. The calcifications lead to a significant deterioration of the modulation transfer function across all spatial frequencies of the affected IOLs. The instillation of exogenous material such as air or gas into the anterior chamber increases the risk for opacification of hydrophilic IOLs irrespective of the manufacturer or the exact composition of the hydrophilic lens material. It is recommended to avoid the use of hydrophilic acrylic IOLs in patients with endothelial dystrophy that will likely require procedures involving the intracameral instillation of air or gas, such as DMEK or DS(A)EK.

  4. Optical analysis, reading performance, and quality-of-life evaluation after implantation of a diffractive multifocal intraocular lens.

    Science.gov (United States)

    Alió, Jorge L; Plaza-Puche, Ana B; Piñero, David P; Amparo, Francisco; Jiménez, Ramón; Rodríguez-Prats, Jose L; Javaloy, Jaime; Pongo, Vanessa

    2011-01-01

    To evaluate the reading performance, changes in quality of life, and optical performance after cataract surgery with multifocal diffractive intraocular lens (IOL) implantation. Vissum Corporation, Alicante, Spain. Prospective case series. Patients with bilateral cataract had implantation of Acri.LISA 366D multifocal IOLs. Visual acuity and contrast sensitivity outcomes were evaluated during a 6-month follow-up. Other parameters evaluated included reading performance (Salzburg Reading Desk), a 25-item quality-of-life questionnaire (National Eye Institute Visual Functioning Questionnaire-25 [NEI VFQ-25] and appendix NEI VFQ-39), and ocular optical performance (ocular aberrometry and modulation transfer function). The study included 48 eyes (24 patients) ranging in age from 47 to 77 years. The mean uncorrected distance visual acuity (logMAR) improved significantly 1 month postoperatively (P<.01), with no significant changes afterward (6 months, P≥.06). The mean reading acuity without correction improved significantly from 0.68 logRAD ± 0.20 (SD) to 0.16 ± 0.08 logRAD 1 month after surgery (P < .01). However, it was worse by the end of the follow-up (6 months, P = .04). During the follow-up, no significant changes were found in the mean reading speed without near correction (6 months, P = .50). Contrast sensitivity improved significantly at all spatial frequencies under photopic and scotopic conditions after surgery (6 months, P≤.02). The quality-of-life index related to reading ability also improved significantly (3 months, P = .03). Implantation of the multifocal diffractive IOL significantly improved reading performance, which had a positive effect on the patient's quality of life postoperatively. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  5. Comparison of optical quality after implantable collamer lens implantation and wavefront-guided laser in situ keratomileusis

    Directory of Open Access Journals (Sweden)

    Hong-Ting Liu

    2018-04-01

    Full Text Available AIM: To compare the optical quality after implantation of implantable collamer lens (ICL and wavefront-guided laser in situ keratomileusis (WG-LASIK. METHODS: The study included 40 eyes of 22 patients with myopia who accepted ICL implantation and 40 eyes of 20 patients with myopia who received WG-LASIK. Before surgery and three months after surgery, the objective scattering index (OSI, the values of modulation transfer function (MTF cutoff frequency, Strehl ratio, and the Optical Quality Analysis System (OQAS values (OVs were accessed. The higher order aberrations (HOAs data including coma, trefoil, spherical, 2nd astigmatism and tetrafoil were also obtained. For patients with pupil size <6 mm, HOAs data were analyzed for 4 mm-pupil diameter. For patients with pupil size ≥6 mm, HOAs data were calculated for 6 mm-pupil diameter. Visual acuity, refraction, pupil size and intraocular pressures were also recorded. RESULTS: In both ICL and WG-LASIK group, significant improvements in visual acuities were found postoperatively, with a significant reduction in spherical equivalent (P< 0.001. After the ICL implantation, the OSI decreased slightly from 2.34±1.92 to 2.24±1.18 with no statistical significance (P=0.62. While in WG-LASIK group, the OSI significantly increased from 0.68±0.43 preoperatively to 0.91±0.53 postoperatively (Wilcoxon signed ranks test, P=0.000. None of the mean MTF cutoff frequency, Strehl ratio, OVs showed statistically significant changes in both ICL and WG-LASIK groups. In the ICL group, there were no statistical differences in the total HOAs for either 4 mm-pupil or 6 mm-pupil. In the WG-LASIK group, the HOA parameters increased significantly at 4 mm-pupil. The total ocular HOAs, coma, spherical and 2nd astigmatism were 0.12±0.06, 0.06±0.03, 0.00±0.03, 0.02±0.01, respectively. After the operation, these values were increased into 0.16±0.07, 0.08±0.05, -0.04±0.04, 0.03±0.01 respectively (Wilcoxon signed ranks test

  6. Planar optical correlators integrated with binary optical lens.

    Science.gov (United States)

    Xu, Ping; Hong, Chunquan; Cheng, Guanxiao; Zhou, Liang; Sun, Zhilong

    2015-03-09

    Planar optical correlators (POCs) can achieve smaller volume of optical system and hence have important applications to identify dynamic targets in complex scenarios. POCs, however, generally have serious astigmatism and optical efficiency loss introduced by its refractive lens with a zigzag optical beam. To conquer the disadvantages of POCs, we propose a type of binary optical planar-integrated optical correlator. The correlator incorporates two pieces of reflective binary optical lens as Fourier transform lens and one spatial light modulator as a programmable filter. The off-axis aberrations commonly occurred in POCs can be corrected by using reflective binary optical lens instead of refractive lens. As a model of hybrid numerical-optical correlator using optoelectronic interface, the proposal is helpful to improve the integration and flexibility and robustness of POCs.

  7. Placement of a crystalline lens and intraocular lens: Retinal image quality.

    Science.gov (United States)

    Siedlecki, Damian; Nowak, Jerzy; Zajac, Marek

    2006-01-01

    The influence of changes of both crystalline lens and intraocular lens (IOL) misalignment on the retinal image quality was investigated. The optical model of the eye used in investigations was the Liou-Brennan model, which is commonly considered as one of the most anatomically accurate. The original crystalline lens from this model was replaced with an IOL, made of rigid polymethylmethacrylate, in a way that recommend obligatory procedures. The modifications that were made both for crystalline lens and IOL were the longitudinal, the transversal, and the angular displacement.

  8. Design of a Test Bench for Intraocular Lens Optical Characterization

    Energy Technology Data Exchange (ETDEWEB)

    Alba-Bueno, Francisco; Vega, Fidel; Millan, Maria S, E-mail: francisco.alba-bueno@upc.edu, E-mail: fvega@oo.upc.edu, E-mail: millan@oo.upc.edu [Departamento de Optica y Optometria, Universidad Politecnica de Cataluna, C/ Violinista Vellsola 37, 08222 Terrassa (Spain)

    2011-01-01

    The crystalline lens is the responsible for focusing at different distances (accommodation) in the human eye. This organ grows throughout life increasing in size and rigidity. Moreover, due this growth it loses transparency through life, and becomes gradually opacified causing what is known as cataracts. Cataract is the most common cause of visual loss in the world. At present, this visual loss is recoverable by surgery in which the opacified lens is destroyed (phacoemulsification) and replaced by the implantation of an intraocular lens (IOL). If the IOL implanted is mono-focal the patient loses its natural capacity of accommodation, and as a consequence they would depend on an external optic correction to focus at different distances. In order to avoid this dependency, multifocal IOLs designs have been developed. The multi-focality can be achieved by using either, a refractive surface with different radii of curvature (refractive IOLs) or incorporating a diffractive surface (diffractive IOLs). To analyze the optical quality of IOLs it is necessary to test them in an optical bench that agrees with the ISO119679-2 1999 standard (Ophthalmic implants. Intraocular lenses. Part 2. Optical Properties and Test Methods). In addition to analyze the IOLs according to the ISO standard, we have designed an optical bench that allows us to simulate the conditions of a real human eye. To do that, we will use artificial corneas with different amounts of optical aberrations and several illumination sources with different spectral distributions. Moreover, the design of the test bench includes the possibility of testing the IOLs under off-axis conditions as well as in the presence of decentration and/or tilt. Finally, the optical imaging quality of the IOLs is assessed by using common metrics like the Modulation Transfer Function (MTF), the Point Spread Function (PSF) and/or the Strehl ratio (SR), or via registration of the IOL's wavefront with a Hartmann-Shack sensor and its

  9. Symmetrical optical imaging system with bionic variable-focus lens for off-axis aberration correction

    Science.gov (United States)

    Wang, Xuan-Yin; Du, Jia-Wei; Zhu, Shi-Qiang

    2017-09-01

    A bionic variable-focus lens with symmetrical layered structure was designed to mimic the crystalline lens. An optical imaging system based on this lens and with a symmetrical structure that mimics the human eye structure was proposed. The refractive index of the bionic variable-focus lens increases from outside to inside. The two PDMS lenses with a certain thickness were designed to improve the optical performance of the optical imaging system and minimise the gravity effect of liquid. The paper presents the overall structure of the optical imaging system and the detailed description of the bionic variable-focus lens. By pumping liquid in or out of the cavity, the surface curvatures of the rear PDMS lens were varied, resulting in a change in the focal length. The focal length range of the optical imaging system was 20.71-24.87 mm. The optical performance of the optical imaging system was evaluated by imaging experiments and analysed by ray tracing simulations. On the basis of test and simulation results, the optical performance of the system was quite satisfactory. Off-axis aberrations were well corrected, and the image quality was greatly improved.

  10. A study of optical design and optimization applied to lens module of laser beam shaping of advanced modern optical device

    Science.gov (United States)

    Tsai, Cheng-Mu; Fang, Yi-Chin; Chen, Zhen Hsiang

    2011-10-01

    This study used the aspheric lens to realize the laser flat-top optimization, and applied the genetic algorithm (GA) to find the optimal results. Using the characteristics of aspheric lens to obtain the optimized high quality Nd: YAG 355 waveband laser flat-top optical system, this study employed the Light tools LDS (least damped square) and the GA of artificial intelligence optimization method to determine the optimal aspheric coefficient and obtain the optimal solution. This study applied the aspheric lens with GA for the flattening of laser beams using two aspheric lenses in the aspheric surface optical system to complete 80% spot narrowing under standard deviation of 0.6142.

  11. Remote nano-optical beam focusing lens by illusion optics

    Science.gov (United States)

    Margousi, David; Shoorian, Hamed Reza

    2014-08-01

    In this paper, as a new application of illusion optics, a nano-optical plasmonic focusing lens structure is proposed to manipulate the light remotely by employing illusion optics theory. Plasmonic nano-optic lenses that enable super-focusing beyond the diffraction limit have been proposed as an alternative to the conventional dielectric-based refractive lenses. In the presence of an illusion device, the electromagnetic plane-waves can penetrate into a metal layer and a clear focus appears. When the illusion device is removed, waves are blocked to transmit through the metal wall. In comparison with conventional methods, our proposed method avoids any physical changes or damages in the original structure. The proposed structure can be realized by isotropic layered materials, using effective medium theory. The special feature of the proposed structure and the device concepts introduced in this work gives it an opportunity to be used as a flexible element in ultrahigh nano-scale integrated circuits for miniaturization and tuning purposes.

  12. Ball Lens Fiber Optic Sensor based Smart Handheld Microsurgical Instrument.

    Science.gov (United States)

    Song, Cheol; Gehlbach, Peter L; Kang, Jin U

    2013-03-20

    During freehand performance of vitreoretinal microsurgery the surgeon must perform precise and stable maneuvers that achieve surgical objectives and avoid surgical risk. Here, we present an improved smart handheld microsurgical tool which is based on a ball lens fiber optic sensor that utilizes common path swept source optical coherence tomography. Improvements include incorporation of a ball lens single mode fiber optic probe that increases the working angle of the tool to greater than 45 degrees; and increases the magnitude of the distance sensing signal through water. Also presented is a cutting function with an improved ergonomic design.

  13. The gravitational lens effect and its optical equivalents

    International Nuclear Information System (INIS)

    Freitas, L.R. de.

    1987-01-01

    This work presents the evolution of the use of the so called gravitational lens effect from a simple observational teste of the General Relativity theory to an instrument to measure cosmological parameters. A detailed analysis of how a gravitational ''lens'' deflects light without forming images is shown for the case of the deflector with spherical symmetry. In addition, the exact optical equivalent of a cylindrical gravitational lens, which forms true images, is proposed. Finally the problem of the formation of multiple images and the related astronomical observations is discussed. (author) [pt

  14. Advanced Optical Signal Processing using Time Lens based Optical Fourier Transformation

    DEFF Research Database (Denmark)

    Guan, Pengyu; Røge, Kasper Meldgaard; Lillieholm, Mads

    2016-01-01

    An overview of recent progress on time lens based advanced optical signal processing is presented, with a special focus on all-optical ultrafast 640 Gbit/s all-channel serial-to-parallel conversion, and scalable WDM regeneration....

  15. Optical time-lens signal processing

    DEFF Research Database (Denmark)

    Oxenløwe, Leif Katsuo; Galili, Michael; Mulvad, Hans Christian Hansen

    2014-01-01

    This paper describes the use of optical time lenses for optical signal processing of advanced optical data signals. Examples given include 1.28 Tbaud Nyquist channel serial-to-parallel conversion and spectral magnification of OFDM signals.......This paper describes the use of optical time lenses for optical signal processing of advanced optical data signals. Examples given include 1.28 Tbaud Nyquist channel serial-to-parallel conversion and spectral magnification of OFDM signals....

  16. Quality control in the optical industry: From a work analysis of lens inspection to a training programme, an experimental case study.

    Science.gov (United States)

    Rebsamen, Maryline; Boucheix, Jean-Michel; Fayol, Michel

    2010-01-01

    A cognitive work analysis of quality inspection in the optical industry has been carried out in order to devise a training programme. The task concerned the inspection of high quality human eyeglass lenses. We conducted an experimental investigation of defect detection and acceptability decision-making tasks in 18 experts and novice inspectors. Detection and decision-making were investigated together and separately in two experimental sessions. We showed the effect of expertise on reaction times and errors, and we described the cognitive processes of novice inspectors. On the basis of the processing differences between the two groups, a training programme for new inspectors was devised and described. Finally, training effects were tested.

  17. Study of the impact of gas temperature and pressure on image quality of lithography objective lens

    Science.gov (United States)

    Zhou, Chao; Xing, Tingwen

    2013-08-01

    The aim of present work is to estimate the impact of gas refractive index shift on the image quality of projection lens caused by the change of environment condition. This work in the paper consists of two parts: a)when temperature rises or reduces, how gas refractive index changes and the wave front error comes up; b)when gas pressure changes. The model objective lens developed for simulation is a US patent lens whose NA patent lens, 5nm, the change caused by gas temperature and pressure can't be neglected. It proves the necessary of compensating or controlling the optical path change resulted from gas refractive index shift during the lithography projection lens work process.

  18. Miniaturized optical sensors based on lens arrays

    DEFF Research Database (Denmark)

    Hanson, Steen Grüner; Jakobsen, M.L.; Larsen, H.E.

    2005-01-01

    A suite of optical sensors based on the use of lenticular arrays for probing mechanical deflections will be displayed. The optical systems are well suited for miniaturization, and utilize speckles as the information-carriers. This implementation allows for acquiring directional information...

  19. Near-diffraction-limited and low-haze electro-optical tunable liquid crystal lens with floating electrodes.

    Science.gov (United States)

    Li, Liwei; Bryant, Doug; Van Heugten, Tony; Bos, Philip J

    2013-04-08

    A near-diffraction-limited, low-haze and tunable liquid crystal (LC) lens is presented. Building on an understanding of the key factors that have limited the performance of lenses based on liquid crystals, we show a simple design whose optical quality is similar to a high quality glass lens. It uses 'floating' electrodes to provide a smooth, controllable applied potential profile across the aperture to manage the phase profile.

  20. Consumer electronic optics: how small can a lens be: the case of panomorph lenses

    Science.gov (United States)

    Thibault, Simon; Parent, Jocelyn; Zhang, Hu; Du, Xiaojun; Roulet, Patrice

    2014-09-01

    In 2014, miniature camera modules are applied to a variety of applications such as webcam, mobile phone, automotive, endoscope, tablets, portable computers and many other products. Mobile phone cameras are probably one of the most challenging parts due to the need for smaller and smaller total track length (TTL) and optimized embedded image processing algorithms. As the technology is developing, higher resolution and higher image quality, new capabilities are required to fulfil the market needs. Consequently, the lens system becomes more complex and requires more optical elements and/or new optical elements. What is the limit? How small an injection molded lens can be? We will discuss those questions by comparing two wide angle lenses for consumer electronic market. The first lens is a 6.56 mm (TTL) panoramic (180° FOV) lens built in 2012. The second is a more recent (2014) panoramic lens (180° FOV) with a TTL of 3.80 mm for mobile phone camera. Both optics are panomorph lenses used with megapixel sensors. Between 2012 and 2014, the development in design and plastic injection molding allowed a reduction of the TTL by more than 40%. This TTL reduction has been achieved by pushing the lens design to the extreme (edge/central air and material thicknesses as well as lens shape). This was also possible due to a better control of the injection molding process and material (low birefringence, haze and thermal stability). These aspects will be presented and discussed. During the next few years, we don't know if new material will come or new process but we will still need innovative people and industries to push again the limits.

  1. Optical architecture of HoloLens mixed reality headset

    Science.gov (United States)

    Kress, Bernard C.; Cummings, William J.

    2017-06-01

    HoloLens by Microsoft Corp. is the world's first untethered Mixed Reality (MR) Head Mounted Display (HMD) system, released to developers in March 2016 as a Development Kit. We review in this paper the various display requirements and subsequent optical hardware choices we made for HoloLens. Its main achievements go along performance and comfort for the user: it is the first fully untethered MR headset, with the highest angular resolution and the industry's largest eyebox. It has the first inside-out global sensor fusion system including precise head tracking and 3D mapping all controlled by a fully custom on-board GPU. Based on such achievements, HoloLens came out as the most advanced MR system today. Additional features may be implemented in next generations MR headsets, leading to the ultimate experience for the user, and securing the upcoming fabulous AR/MR market predicted by most analysts.

  2. Time-lens based optical packet pulse compression and retiming

    DEFF Research Database (Denmark)

    Laguardia Areal, Janaina; Hu, Hao; Palushani, Evarist

    2010-01-01

    This paper presents a new optical circuit that performs both pulse compression and frame synchronization and retiming. Our design aims at directly multiplexing several 10G Ethernet data packets (frames) to a high-speed OTDM link. This scheme is optically transparent and does not require clock...... recovery, resulting in a potentially very efficient solution. The scheme uses a time-lens, implemented through a sinusoidally driven optical phase modulation, combined with a linear dispersion element. As time-lenses are also used for pulse compression, we design the circuit also to perform pulse...

  3. Geometric optical optimization of the corneal lens of Notonecta glauca.

    Science.gov (United States)

    Horváth, G

    1989-08-09

    The optimal shape of the corneal lens of the water bug backswimmer (Notonecta glauca) and the optimal shape and position of the thin transition layer between the distal and proximal units of its cornea are theoretically determined. Using a geometric optical method, first the shape of a geometric interface between the lens units is determined, which eliminates the longitudinal spherical aberration. This interface is investigated for differently formed thick lenses when the medium in contact with the entrance surface of the lens is water or air. The optimal transition layer for the amphibious backswimmer is that, the boundaries of which are the theoretical interfaces for water and air, and the refractive index varies continuously in it. The optimal shape of the corneal lens is determined, with the disadvantageous lenses, with respect to the possible minimal spherical aberration and amount of reflected light from the transition layer, being rejected. The optimal position of the transition layer in the cornea can be obtained from the minimization of the amount of diffracted light on the marginal connection of the layers. The optimal corneal lens for backswimmer has ellipsoid boundary surfaces; the optimal transition layer in it is thin bell-shaped, at the marginal connection of which there is no dimple, the maximum of the layer is on the margin of the cornea. The shape of the theoretically optimal corneal lens, the shape and position of the theoretically optimal transition layer agree well with those of Notonecta glauca. The question posed, the geometric optical method used and the results presented are of general importance, and not only with respect to vision in the bug Notonecta, but also in the fossil trilobites, or in the wave guide theories which have been employed in similar modelling problems, in design of system of lenses without spherical aberration, for example.

  4. Noncontact optical measurement of lens capsule thickness ex vivo

    Science.gov (United States)

    Ziebarth, Noel M.; Manns, Fabrice; Uhlhorn, Stephen; Parel, Jean-Marie

    2004-07-01

    Purpose: To design a non-contact optical system to measure lens capsule thickness in cadaver eyes. Methods: The optical system uses a 670nm laser beam delivered to a single-mode fiber coupler. The output of the fiber coupler is focused onto the tissue using an aspheric lens (NA=0.68) mounted on a motorized translation stage. Light reflected from the sample is collected by the fiber coupler and sent to a silicon photodiode connected to a power meter. Peaks in the power signal are detected when the focal point of the aspheric lens coincides with the capsule boundaries. The capsule thickness is proportional to the distance between successive peaks. Anterior and posterior lens capsule thickness measurements were performed on 13 human, 10 monkey, and 34 New Zealand white rabbit lenses. The cadaver eyes were prepared for optical measurements by bonding a PMMA ring on the sclera. The posterior pole was sectioned, excess vitreous was removed, and the eye was placed on a Teflon slide. The cornea and iris were then sectioned. After the experiments, the lenses were excised, placed in 10% buffered formalin, and prepared for histology. Results: Central anterior lens capsule thickness was 9.4+/-2.9μm (human), 11.2+/-6.6μm (monkey), and 10.3+/-3.6μm (rabbit) optically and 14.9+/-1.6μm (human), 17.7+/-4.9μm (monkey), and 12.6+/-2.3μm (rabbit) histologically. The values for the central posterior capsule were 9.4+/-2.9μm (human), 6.6+/-2.5μm (monkey), and 7.9+/-2.3μm (rabbit) optically and 4.6+/-1.4μm (human), 4.5+/-1.2μm (monkey), and 5.7+/-1.7μm (rabbit) histologically. Conclusions: This study demonstrates that a non-contact optical system can successfully measure lens capsule thickness in cadaver eyes.

  5. Overlapped illusion optics: a perfect lens brings a brighter feature

    Energy Technology Data Exchange (ETDEWEB)

    Xu Yadong; Gao Lei; Chen Huanyang [School of Physical Science and Technology, Soochow University, Suzhou, Jiangsu 215006 (China); Du Shengwang, E-mail: kenyon@ust.hk [Department of Physics, Hong Kong University of Science and Technology, Clear Water Bay, Kowloon (Hong Kong)

    2011-02-15

    In this paper, we show that a perfect lens can be employed to make multiple objects appear like only one object in the far field, leading to a new concept in illusion optics. Numerical simulations have been performed to verify the functionalities for both passive and active objects. The conceptual device can be utilized to enhance the illumination brightness for both incoherent and coherent systems.

  6. Overlapped illusion optics: a perfect lens brings a brighter feature

    International Nuclear Information System (INIS)

    Xu Yadong; Gao Lei; Chen Huanyang; Du Shengwang

    2011-01-01

    In this paper, we show that a perfect lens can be employed to make multiple objects appear like only one object in the far field, leading to a new concept in illusion optics. Numerical simulations have been performed to verify the functionalities for both passive and active objects. The conceptual device can be utilized to enhance the illumination brightness for both incoherent and coherent systems.

  7. Time Lens based Optical Fourier Transformation for All-Optical Signal Processing of Spectrally-Efficient Data

    DEFF Research Database (Denmark)

    Guan, Pengyu; Røge, Kasper Meldgaard; Lillieholm, Mads

    2017-01-01

    We review recent progress in the use of time lens based optical Fourier transformation for advanced all-optical signal processing. A novel time lens based complete optical Fourier transformation (OFT) technique is introduced. This complete OFT is based on two quadratic phase-modulation stages using...

  8. Fabrication of an optical lens array using ultraviolet light and ultrasonication.

    Science.gov (United States)

    Taniguchi, Satoki; Koyama, Daisuke; Nakamura, Kentaro; Matsukawa, Mami

    2015-04-01

    A technique to form an optical lens array using an ultraviolet (UV)-curable resin and ultrasound was investigated. A UV-curable gel film was formed on a glass plate having four lead zirconate titanate (PZT) transducers. Excitation of the transducers generated a lattice flexural vibration mode on the glass plate. The acoustic radiation force acted to deform the surface of the gel film, so that a lens array could be fabricated on the gel film. The lens array was exposed to UV light under ultrasonication to cure the UV-curable film. The quality factor of the transducer resonance was decreased upon curing of the resin film because the cured resin dampened the vibration of the plate. The acoustic characteristics of the UV-curable gel film were measured by using an ultrasound pulse technique at the MHz range. The sound speed of the gel increased from 987 to 1006 m/s (increase of 1.9%) as the UV exposure time increased. The attenuation coefficient also increased and the larger attenuation of the resin caused the lens array to have a lower quality factor. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Optical Tests on a Curve Fresnel Lens as Secondary Optics for Solar Troughs

    Directory of Open Access Journals (Sweden)

    D. Fontani

    2017-01-01

    Full Text Available A curve Fresnel lens is developed as secondary concentrator for solar parabolic troughs to reduce the number of photovoltaic cells. Specific measurements and optical tests are used to evaluate the optical features of manufactured samples. The cylindrical Fresnel lens transforms the focal line, produced by the primary mirror, into a series of focal points. The execution of special laboratory tests on some secondary concentrator samples is discussed in detail, illustrating the methodologies tailored to the specific case. Focusing tests are performed, illuminating different areas of the lens with solar divergence light and acquiring images on the plane of the photocell using a CMOS camera. Concentration measurements are carried out to select the best performing samples of curve Fresnel lens. The insertion of the secondary optics within the concentrating photovoltaic (CPV trough doubles the solar concentration of the system. The mean concentration ratio is 1.73, 2.13, and 2.09 for the three tested lenses. The concentration ratio of the solar trough is 140 and approaches 300 after the introduction of the secondary lens.

  10. Optical design of transmitter lens for asymmetric distributed free space optical networks

    Science.gov (United States)

    Wojtanowski, Jacek; Traczyk, Maciej

    2018-05-01

    We present a method of transmitter lens design dedicated for light distribution shaping on a curved and asymmetric target. In this context, target is understood as a surface determined by hypothetical optical detectors locations. In the proposed method, ribbon-like surfaces of arbitrary shape are considered. The designed lens has the task to transform collimated and generally non-uniform input beam into desired irradiance distribution on such irregular targets. Desired irradiance is associated with space-dependant efficiency of power flow between the source and receivers distributed on the target surface. This unconventional nonimaging task is different from most illumination or beam shaping objectives, where constant or prescribed irradiance has to be produced on a flat target screen. The discussed optical challenge comes from the applications where single transmitter cooperates with multitude of receivers located in various positions in space and oriented in various directions. The proposed approach is not limited to optical networks, but can be applied in a variety of other applications where nonconventional irradiance distribution has to be engineered. The described method of lens design is based on geometrical optics, radiometry and ray mapping philosophy. Rays are processed as a vector field, each of them carrying a certain amount of power. Having the target surface shape and orientation of receivers distribution, the rays-surface crossings map is calculated. It corresponds to the output rays vector field, which is referred to the calculated input rays spatial distribution on the designed optical surface. The application of Snell's law in a vector form allows one to obtain surface local normal vector and calculate lens profile. In the paper, we also present the case study dealing with exemplary optical network. The designed freeform lens is implemented in commercially available optical design software and irradiance three-dimensional spatial distribution is

  11. [Visual quality comparison after multifocal toric intraocular lens or monofocal toric intraocular lens implantation].

    Science.gov (United States)

    Feng, K; Guo, H K; Zhang, Y L; Wu, Z

    2017-04-11

    Objective: To compare visual quality and satisfaction after multifocal toric intraocular lens (Acrysof IQ Restor toric, ART) and monofocal toric intraocular lens implantation in patients. Methods: It was a prospective nonrandomized Phase Ⅲ clinical trial. Patients with age-related cataract and corneal astigmatism were enrolled and accepted phacoemulsification combined with implantation of intraocular lens (IOL) in Henan Provincial Eye Hospital during March 2013 to December 2014. Fifty-six cases were divided into two groups according to which IOL they chose. ART group included 28 cases (3l eyes) aged from 41.0 to 72.0 years, with an average age of 61.5 years; toric group included 28 cases (33 eyes) aged from 42.0 to 75.0 years, with an average age of 63.5 years. Three months postoperatively, uncorrected distance visual acuity (UDVA) at 5, 70, 40 cm, corrected distance, intermediate, and near visual acuities, defocus curve, residual refractive astigmatism, rotational stability of the IOL, contrast sensitivity and patientsatisfaction were evaluated. All data were processed by statistic package deal SPSS 16.0. Postoperative visual acuity, residual astigmatism, IOL axial rotation and contrast sensitivity were compared by independent samples t test; preoperative and postoperative corneal astigmatism were compared by paired t -test; spectacle independency and halo incidence were processed by χ(2) test; visual satisfaction score was analyzed by Mann-Whitney test. Results: At 3 months postoperatively, in ART group, UDVA was (0.04±0.05), UIVA was (0.24±0.15), UNVA was (0.20±0.24). While in Toric group, UDVA was (0.06±0.04), UIVA was (0.30±0.13), UNVA was (0.47±0.21). There was no significant difference in UDVA between two groups( t= 0.79, P= 0.433). But in ART group, UIVA and UNVA were markedly better than those in Toric group( t= 2.74, P= 0.008; t= 3.45, PART group and 2.50 D (+1.00--1.50 D) in the Toric group. Average postoperative residual astigmatism was (-0.45

  12. A super-oscillatory lens optical microscope for subwavelength imaging.

    Science.gov (United States)

    Rogers, Edward T F; Lindberg, Jari; Roy, Tapashree; Savo, Salvatore; Chad, John E; Dennis, Mark R; Zheludev, Nikolay I

    2012-03-25

    The past decade has seen an intensive effort to achieve optical imaging resolution beyond the diffraction limit. Apart from the Pendry-Veselago negative index superlens, implementation of which in optics faces challenges of losses and as yet unattainable fabrication finesse, other super-resolution approaches necessitate the lens either to be in the near proximity of the object or manufactured on it, or work only for a narrow class of samples, such as intensely luminescent or sparse objects. Here we report a new super-resolution microscope for optical imaging that beats the diffraction limit of conventional instruments and the recently demonstrated near-field optical superlens and hyperlens. This non-invasive subwavelength imaging paradigm uses a binary amplitude mask for direct focusing of laser light into a subwavelength spot in the post-evanescent field by precisely tailoring the interference of a large number of beams diffracted from a nanostructured mask. The new technology, which--in principle--has no physical limits on resolution, could be universally used for imaging at any wavelength and does not depend on the luminescence of the object, which can be tens of micrometres away from the mask. It has been implemented as a straightforward modification of a conventional microscope showing resolution better than λ/6.

  13. Multiobjective Optimization of Injection Molding Process Parameters for the Precision Manufacturing of Plastic Optical Lens

    Directory of Open Access Journals (Sweden)

    Junhui Liu

    2017-01-01

    Full Text Available Injection molding process parameters (IMPP have a significant effect on the optical performance and surface waviness of precision plastic optical lens. This paper presents a set of procedures for the optimization of IMPP, with haze ratio (HR reflecting the optical performance and peak-to-valley 20 (PV20 reflecting the surface waviness as the optimization objectives. First, the orthogonal experiment was carried out with the Taguchi method, and the results were analyzed by ANOVA to screen out the IMPP having a significant effect on the objectives. Then, the 34 full-factor experiment was conducted on the key IMPP, and the experimental results were used as the training and testing samples. The BPNN algorithm and the M-SVR algorithm were applied to establish the mapping relationships between the IMPP and objectives. Finally, the multiple-objective optimization was performed by applying the nondominated sorting genetic algorithm (NSGA-II, with the built M-SVR models as the fitness function of the objectives, to obtain a Pareto-optimal set, which improved the quality of plastic optical lens comprehensively. Through the experimental verification on the optimization results, the mean prediction error (MPE of HR and PV20 is 7.16% and 9.78%, respectively, indicating that the optimization method has high accuracy.

  14. Determination of optical parameters of a GRIN lens by intercept measurement

    Science.gov (United States)

    Zhang, Yufei; Xiong, Baoxing; Xu, Qinfeng; Guo, Changwei; Zhang, Guiju; Xu, Feng; Zou, Kuaisheng

    2018-03-01

    An experimental method is used to measure the optical parameters of a GRIN lens. The intrinsic properties of the lens are well characterized by measuring the intercept values of the different GRIN lenses. Firstly, the intercept equation is derived from the transmission matrix of the GRIN lens, and the measurement method is described in detail. Secondly, we design and make the optical path measuring system. Finally, the error analysis of the experimental results is presented, which shows the feasibility of the working principle and the experiment operation. The principle and equipment of this measuring method are relatively effective, which affords great practical significance for the measurement of the GRIN lens.

  15. Apparatus for Direct Optical Fiber Through-Lens Illumination of Microscopy or Observational Objects

    Science.gov (United States)

    Kadogawa, Hiroshi (Inventor)

    2001-01-01

    In one embodiment of the invention, a microscope or other observational apparatus, comprises a hollow tube, a lens mounted to the tube, a light source and at least one flexible optical fiber having an input end and an output end. The input end is positioned to receive light from the light source, and the output end is positioned within the tube so as to directly project light along a straight path to the lens to illuminate an object to be viewed. The path of projected light is uninterrupted and free of light deflecting elements. By passing the light through the lens, the light can be diffused or otherwise defocused to provide more uniform illumination across the surface of the object, increasing the quality of the image of the object seen by the viewer. The direct undeflected and uninterrupted projection of light, without change of direction, eliminates the need for light-deflecting elements, such as beam-splitters, mirrors, prisms, or the like, to direct the projected light towards the object.

  16. Tunable optical lens array using viscoelastic material and acoustic radiation force

    Energy Technology Data Exchange (ETDEWEB)

    Koyama, Daisuke, E-mail: dkoyama@mail.doshisha.ac.jp; Kashihara, Yuta; Matsukawa, Mami [Faculty of Science and Engineering, Doshisha University, 1-3 Tataramiyakodani, Kyotanabe 610-0321 (Japan); Wave Electronics Research Center, Doshisha University, 1-3 Tataramiyakodani, Kyotanabe 610-0321 (Japan); Hatanaka, Megumi [Faculty of Life and Medical Sciences, Doshisha University, 1-3 Tataramiyakodani, Kyotanabe 610-0321 (Japan); Wave Electronics Research Center, Doshisha University, 1-3 Tataramiyakodani, Kyotanabe 610-0321 (Japan); Nakamura, Kentaro [Precision and Intelligence Laboratory, Tokyo Institute of Technology, 4259-R2-26, Nagatsutacho, Midoriku, Yokohama 226-8503 (Japan)

    2015-10-28

    A movable optical lens array that uses acoustic radiation force was investigated. The lens array consists of a glass plate, two piezoelectric bimorph transducers, and a transparent viscoelastic gel film. A cylindrical lens array with a lens pitch of 4.6 mm was fabricated using the acoustic radiation force generated by the flexural vibration of the glass plate. The focal point and the positioning of the lenses can be changed using the input voltage and the driving phase difference between the two transducers, respectively.

  17. Characterization of a tunable astigmatic fluidic lens with adaptive optics correction for compact phoropter application

    Science.gov (United States)

    Fuh, Yiin-Kuen; Huang, Chieh-Tse

    2014-07-01

    Fluidically controlled lenses which adaptively correct prescribed refractive error without mechanically moving parts are extensively applied in the ophthalmic applications. Capable of variable-focusing properties, however, the associated aberrations due to curvature change and refractive index mismatch can inherently degrade image quality severely. Here we present the experimental study of the aberrations in tunable astigmatic lens and use of adaptive optics to compensate for the wavefront errors. Characterization of the optical properties of the individual lenses is carried out by Shack-Hartmann measurements. An adaptive optics (AO) based scheme is demonstrated for three injected fluidic volumes, resulting in a substantial reduction of the wavefront errors from -0.12, -0.25, -0.32 to 0.01, -0.01, -0.20 μm, respectively, corresponding to the optical power tenability of 0.83 to 1.84 D. Furthermore, an integrated optical phoroptor consisting of adjustable astigmatic lenses and AO correction is demonstrated such that an induced refraction error of -1 D cylinder at 180° of a model eye vision is experimentally corrected.

  18. Comparison of two optical biometers in intraocular lens power calculation

    Directory of Open Access Journals (Sweden)

    Sheng Hui

    2014-01-01

    Full Text Available Aims: To compare the consistency and accuracy in ocular biometric measurements and intraocular lens (IOL power calculations using the new optical low-coherence reflectometry and partial coherence interferometry. Subjects and Methods: The clinical data of 122 eyes of 72 cataract patients were analyzed retrospectively. All patients were measured with a new optical low-coherence reflectometry system, using the LENSTAR LS 900 (Haag Streit AG/ALLEGRO BioGraph biometer (Wavelight., AG, and partial coherence interferometry (IOLMaster V.5.4 [Carl Zeiss., Meditec, AG] before phacoemulsification and IOL implantation. Repeated measurements, as recommended by the manufacturers, were performed by the same examiner with both devices. Using the parameters of axial length (AL, corneal refractive power (K1 and K2, and anterior chamber depth (ACD, power calculations for AcrySof SA60AT IOL were compared between the two devices using five formulas. The target was emmetropia. Statistical analysis was performed using Statistical Package for the Social Sciences software (SPSS 13.0 with t-test as well as linear regression. A P value < 0.05 was considered to be statistically significant. Results: The mean age of 72 cataract patients was 64.6 years ± 13.4 [standard deviation]. Of the biometry parameters, K1, K2 and [K1 + K2]/2 values were significantly different between the two devices (mean difference, K1: −0.05 ± 0.21 D; K2: −0.12 ± 0.20 D; [K1 + K2]/2: −0.08 ± 0.14 D. P <0.05. There was no statistically significant difference in AL and ACD between the two devices. The correlations of AL, K1, K2, and ACD between the two devices were high. The mean differences in IOL power calculations using the five formulas were not statistically significant between the two devices. Conclusions: New optical low-coherence reflectometry provides measurements that correlate well to those of partial coherence interferometry, thus it is a precise device that can be used for the

  19. Reducing aberration effect of Fourier transform lens by modifying Fourier spectrum of diffractive optical element in beam shaping optical system.

    Science.gov (United States)

    Zhang, Fang; Zhu, Jing; Song, Qiang; Yue, Weirui; Liu, Jingdan; Wang, Jian; Situ, Guohai; Huang, Huijie

    2015-10-20

    In general, Fourier transform lenses are considered as ideal in the design algorithms of diffractive optical elements (DOEs). However, the inherent aberrations of a real Fourier transform lens disturb the far field pattern. The difference between the generated pattern and the expected design will impact the system performance. Therefore, a method for modifying the Fourier spectrum of DOEs without introducing other optical elements to reduce the aberration effect of the Fourier transform lens is proposed. By applying this method, beam shaping performance is improved markedly for the optical system with a real Fourier transform lens. The experiments carried out with a commercial Fourier transform lens give evidence for this method. The method is capable of reducing the system complexity as well as improving its performance.

  20. A New Optical System for Holographic Memory Applying a Finite Objective Lens

    Science.gov (United States)

    Yamakage, Yuzuru; Uno, Kazushi; Iwamura, Yasumasa; Shimokawa, Satoshi; Yoshikawa, Hiroyasu; Tezuka, Koichi; Ozaki, Kazuyuki

    2008-07-01

    We have developed a new objective lens for a holographic storage system to increase areal density. To balance focal length and working distance, we adopted a finite objective lens. By incorporating phase conjugate reproduction into the finite objective lens, we obtained practically applicable and adequate signal quality. We measured shift selectivity and the effect of crosstalk and evaluated book size, which was reduced by ca. 0.8. The areal density was estimated to increase by about 1.6 times when using the new objective lens.

  1. Swept Source Optical Coherence Tomography Angiography for Contact Lens-Related Corneal Vascularization

    Directory of Open Access Journals (Sweden)

    Marcus Ang

    2016-01-01

    Full Text Available Purpose. To describe a novel technique of adapting a swept-source optical coherence tomography angiography (OCTA to image corneal vascularization. Methods. In this pilot cross-sectional study, we obtained 3 × 3 mm scans, where 100,000 A-scans are acquired per second with optical axial resolution of 8 μm and lateral resolution of 20 μm. This was performed with manual “XYZ” focus without the anterior segment lens, until the focus of the corneoscleral surface was clearly seen and the vessels of interest were in focus on the corresponding red-free image. En face scans were evaluated based on image quality score and repeatability. Results. We analyzed scans from 10 eyes (10 patients with corneal vascularization secondary to contact lens use in 4 quadrants, with substantial repeatability of scans in all quadrants (mean image quality score 2.7 ± 0.7; κ=0.75. There was no significant difference in image quality scores comparing quadrants (superior temporal: 2.9 ± 0.6, superior nasal: 2.8 ± 0.4, inferior temporal: 2.5 ± 0.9, and inferior nasal: 2.4 ± 1.0; P=0.276 and able to differentiate deep and superficial corneal vascularization. Conclusion. This early clinical study suggests that the swept-source OCTA used may be useful for examining corneal vascularization, which may have potential for clinical applications such as detecting early limbal stem cell damage.

  2. Time lens based optical fourier transformation for advanced processing of spectrally-efficient OFDM and N-WDM signals

    DEFF Research Database (Denmark)

    Guan, Pengyu; Røge, Kasper Meldgaard; Morioka, Toshio

    2016-01-01

    We review recent progress in the use of time lens based optical Fourier transformation for advanced optical signal processing, with focus on all-optical generation, detection and format conversion of spectrally-efficient OFDM and N-WDM signals.......We review recent progress in the use of time lens based optical Fourier transformation for advanced optical signal processing, with focus on all-optical generation, detection and format conversion of spectrally-efficient OFDM and N-WDM signals....

  3. An analytical method for predicting the geometrical and optical properties of the human lens under accommodation

    Science.gov (United States)

    Sheil, Conor J.; Bahrami, Mehdi; Goncharov, Alexander V.

    2014-01-01

    We present an analytical method to describe the accommodative changes in the human crystalline lens. The method is based on the geometry-invariant lens model, in which the gradient-index (GRIN) iso-indicial contours are coupled to the external shape. This feature ensures that any given number of iso-indicial contours does not change with accommodation, which preserves the optical integrity of the GRIN structure. The coupling also enables us to define the GRIN structure if the radii and asphericities of the external lens surfaces are known. As an example, the accommodative changes in lenticular radii and central thickness were taken from the literature, while the asphericities of the external surfaces were derived analytically by adhering to the basic physical conditions of constant lens volume and its axial position. The resulting changes in lens geometry are consistent with experimental data, and the optical properties are in line with expected values for optical power and spherical aberration. The aim of the paper is to provide an anatomically and optically accurate lens model that is valid for 3 mm pupils and can be used as a new tool for better understanding of accommodation. PMID:24877022

  4. Non-contact optical measurement of lens capsule thickness during simulated accommodation

    Science.gov (United States)

    Ziebarth, Noel; Manns, Fabrice; Acosta, Ana-Carolina; Parel, Jean-Marie

    2005-04-01

    Purpose: To non-invasively measure the thickness of the anterior and posterior lens capsule, and to determine if it significantly changes during accommodation. Methods: Anterior and posterior capsule thickness was measured on post-mortem lenses using a non-contact optical system using a focus-detection technique. The optical system uses a 670nm laser beam delivered to a single-mode fiber coupler. The output of the fiber coupler is focused on the tissue surface using an aspheric lens (NA=0.68) mounted on a translation stage with a motorized actuator. Light reflected from the sample surface is collected by the fiber coupler and sent to a photoreceiver connected to a computer-controlled data acquisition system. Optical intensity peaks are detected when the aspheric lens is focused on the capsule boundaries. The capsule thickness is equal to the distance traveled between two peaks multiplied by the capsule refractive index. Anterior and posterior lens capsule thickness measurements were performed on 18 cynomolgus (age average: 6+/-1 years, range: 4-7 years) eyes, 1 rhesus (age: 2 years) eye, and 12 human (age average: 65+/-16, range: 47-92) eyes during simulated accommodation. The mounted sample was placed under the focusing objective of the optical system so that the light was incident on the center pole. Measurements were taken of the anterior lens capsule in the unstretched and the stretched 5mm states. The lens was flipped, and the same procedure was performed for the posterior lens capsule. Results: The precision of the optical system was determined to be +/-0.5um. The resolution is 4um and the sensitivity is 52dB. The human anterior lens capsule thickness was 6.0+/-1.2um unstretched and 4.9+/-0.9um stretched (p=0.008). The human posterior lens capsule was 5.7+/-1.2um unstretched and 5.7+/-1.4um stretched (p=0.974). The monkey anterior lens capsule thickness was 5.9+/-1.9um unstretched and 4.8+/-1.0um stretched (p=0.002). The monkey posterior lens capsule was 5

  5. Angular and spectral sensitivity of fly photoreceptors. I. Integrated facet lens and rhabdomere optics

    NARCIS (Netherlands)

    Stavenga, D.G.

    Three optical components of a fly’s eye determine the angular sensitivity of the photoreceptors: the light diffracting facet lens, the wave-guiding rhabdomere and the light-absorbing visual pigment in the rhabdomere. How the integrated optical system of the fly eye shapes the angular sensitivity

  6. Quantitative Analysis of Lens Nuclear Density Using Optical Coherence Tomography (OCT with a Liquid Optics Interface: Correlation between OCT Images and LOCS III Grading

    Directory of Open Access Journals (Sweden)

    You Na Kim

    2016-01-01

    Full Text Available Purpose. To quantify whole lens and nuclear lens densities using anterior-segment optical coherence tomography (OCT with a liquid optics interface and evaluate their correlation with Lens Opacities Classification System III (LOCS III lens grading and corrected distance visual acuity (BCVA. Methods. OCT images of the whole lens and lens nucleus of eyes with age-related nuclear cataract were analyzed using ImageJ software. The lens grade and nuclear density were represented in pixel intensity units (PIU and correlations between PIU, BCVA, and LOCS III were assessed. Results. Forty-seven eyes were analyzed. The mean whole lens and lens nuclear densities were 26.99 ± 5.23 and 19.43 ± 6.15 PIU, respectively. A positive linear correlation was observed between lens opacities (R2 = 0.187, p<0.01 and nuclear density (R2 = 0.316, p<0.01 obtained from OCT images and LOCS III. Preoperative BCVA and LOCS III were also positively correlated (R2 = 0.454, p<0.01. Conclusions. Whole lens and lens nuclear densities obtained from OCT correlated with LOCS III. Nuclear density showed a higher positive correlation with LOCS III than whole lens density. OCT with a liquid optics interface is a potential quantitative method for lens grading and can aid in monitoring and managing age-related cataracts.

  7. Semiautomated analysis of optical coherence tomography crystalline lens images under simulated accommodation.

    Science.gov (United States)

    Kim, Eon; Ehrmann, Klaus; Uhlhorn, Stephen; Borja, David; Arrieta-Quintero, Esdras; Parel, Jean-Marie

    2011-05-01

    Presbyopia is an age related, gradual loss of accommodation, mainly due to changes in the crystalline lens. As part of research efforts to understand and cure this condition, ex vivo, cross-sectional optical coherence tomography images of crystalline lenses were obtained by using the Ex-Vivo Accommodation Simulator (EVAS II) instrument and analyzed to extract their physical and optical properties. Various filters and edge detection methods were applied to isolate the edge contour. An ellipse is fitted to the lens outline to obtain central reference point for transforming the pixel data into the analysis coordinate system. This allows for the fitting of a high order equation to obtain a mathematical description of the edge contour, which obeys constraints of continuity as well as zero to infinite surface slopes from apex to equator. Geometrical parameters of the lens were determined for the lens images captured at different accommodative states. Various curve fitting functions were developed to mathematically describe the anterior and posterior surfaces of the lens. Their differences were evaluated and their suitability for extracting optical performance of the lens was assessed. The robustness of these algorithms was tested by analyzing the same images repeated times.

  8. Common Path Side Viewing Monolithic Ball Lens Probe for Optical Coherence Tomography

    OpenAIRE

    Kanwarpal, Singh; Daisuke, Yamada; Guillermo, Tearney

    2015-01-01

    Common path probes are highly desirable for optical coherence tomography as they reduce system complexity and cost by eliminating the need of dispersion compensation and polarization controlling optics. In this work, we demonstrate a monolithic ball lens based, common path, side viewing probe that is suitable for Fourier domain optical coherence tomography. The probe design parameters were simulated in Zemax modeling software and the simulated performance parameters were compared with experim...

  9. Optical turbulence in a spinning pipe gas lens

    CSIR Research Space (South Africa)

    Mafusire, C

    2009-07-01

    Full Text Available The researchers have managed to do quantitative analysis of ‘controlled’ turbulence. The researchers could control the degree of turbulence by controlling the rotation speed and wall temperature of the spinning pipe gas lens. The researchers also...

  10. [Current quality management situation and administration countermeasure study of enterprises marketing corneal contact lens].

    Science.gov (United States)

    Liu, Yungui; Yao, Ying; Shangguan, Shihao; Gu, Qun; Gao, Wuming; Chen, Yaoshui

    2014-05-01

    Study the current quality management situation of enterprises marketing corneal contact lens via systemic investigations and explore effective administration countermeasures in the future. The quality management indicators of sixty-two corneal contact lens marketing enterprises in Xuhui district of Shanghai were systematically investigated and enterprises of different operation models was compared and analyzed. Wholesale enterprises and retail chain enterprises are apparently better than independent enterprises almost in all facets. Facilitate market accession of corneal contact lens marketing enterprises, encourage the business model of retail chain, enhance supervision of corneal contact lens marketing enterprises, especially independent franchisors.

  11. Lens decenter and tilt measurement by interferogram

    Science.gov (United States)

    Hung, Min-Wei; Wu, Wen-Hong; Huang, Kuo-Cheng

    2009-11-01

    For the recent years, the vigorous development of the electro-optic industry, particularly the digital camera and the cellular phone camera, has placed a larger and larger demand for the optical devices. Among the optical lens, the aspherical optical lens plays the key component because the aspherical lens may provide better imaging quality then the spherical lens does. For the manufacturing reason, the aspherical lens is prone to a decenter or tilt issue with respect to the optical axes of its two surfaces. To measure decenter and tile error specifically would help to obviate the deficient lens, but most of the present measuring method can't provide this function. This paper proposed a new method to specifically measure the decenter and tile of lens by observing the interferogram of each surface. And the corresponding measuring instrument, which contains interferometer and motion stages, was introduced as well.

  12. Ball lens based lensed patch cord probes for optical coherence tomography in the field of dentistry

    Science.gov (United States)

    Eom, J. B.; Kim, Y.; Lee, S. J.; Min, E. J.; Park, S. J.; Lee, B. H.

    2012-10-01

    A lensed patch cord probe has been made with a ball lens packaged in a metal cylinder. By simply placing a ball lens directly in front of a fiber patch cord, a compact and potentially disposable sampling probe for optical coherence tomography (OCT) could be implemented. To achieve a sufficiently long working distance and a good transverse resolution simultaneously, the proper ball lens diameter and the distance between the ball lens and the fiber patch cord were investigated. Experimentally, a working distance of up to 5.2 mm, 3 dB bandwidth of 2 mm, and transverse resolution of 16 μm were achieved. With the patch cord probe, a common path swept source OCT system was implemented and used to demonstrate the feasibility as the dedicated probe for dentistry.

  13. Power Profiles and In Vitro Optical Quality of Scleral Contact Lenses: Effect of the Aperture and Power.

    Science.gov (United States)

    Domínguez-Vicent, Alberto; Esteve-Taboada, Jose Juan; Recchioni, Alberto; Brautaset, Rune

    2017-01-13

    To assess the power profile and in vitro optical quality of scleral contact lenses with different powers as a function of the optical aperture. The mini and semiscleral contact lenses (Procornea) were measured for five powers per design. The NIMO TR-1504 (Lambda-X) was used to assess the power profile and Zernike coefficients of each contact lens. Ten measurements per lens were taken at 3- and 6-mm apertures. Furthermore, the optical quality of each lens was described in Zernike coefficients, modulation transfer function, and point spread function (PSF). A convolution of each lens PSF with an eye-chart image was also computed. The optical power fluctuated less than 0.5 diopters (D) along the optical zone of each lens. However, the optical power obtained for some lenses did not match with its corresponding nominal one, the maximum difference being 0.5 D. In optical quality, small differences were obtained among all lenses within the same design. Although significant differences were obtained among lenses (Pscleral lens. Additionally, the optical quality of both lenses has showed to be independent of the lens power within the same aperture.

  14. Gradient-index optical fiber lens for efficient fiber-to-chip coupling.

    Science.gov (United States)

    Melkonyan, Henrik; Al Qubaisi, Kenaish; Sloyan, Karen; Khilo, Anatol; Dahlem, Marcus S

    2017-06-12

    A gradient-index optical fiber lens is proposed and fabricated on the tip of a single-mode fiber using focused ion beam milling. Second-order effective medium theory is used to design a gradual change in the fill factor, which ensures a parabolic effective refractive index distribution. The proposed fiber lens design is simulated via the three-dimensional finite-difference time-domain method, and demonstrated through confocal optical measurements. At a wavelength of 1550 nm, the fabricated lenses focus a 10.4 μm mode field diameter exiting the fiber into spot sizes between 3-5 μm, located 4-6 μm away from the fiber tip. Direct coupling into a silicon-on-insulator chip is also demonstrated, where the fabricated gradient-index lens has a coupling efficiency comparable to a commercial lensed fiber.

  15. Probing the negative permittivity perfect lens at optical frequencies using near-field optics and single molecule detection

    NARCIS (Netherlands)

    Moerland, R.J.; van Hulst, N.F.; Gersen, H.; Kuipers, L.

    2005-01-01

    Recently, the existence of a perfect lens has been predicted, made of an artificial material that has a negative electric permittivity and a negative magnetic permeability. For optical frequencies a poormans version is predicted to exist in the sub-wavelength limit. Then, only the permittivity has

  16. Differences in lens optical plasticity in two gadoid fishes meeting in the Arctic.

    Science.gov (United States)

    Jönsson, Mikael; Varpe, Øystein; Kozłowski, Tomasz; Berge, Jørgen; Kröger, Ronald H H

    2014-11-01

    Arctic and boreal/temperate species are likely to be evolutionary adapted to different light regimes. Currently, the boreal/temperate Atlantic cod (Gadus morhua) is coexisting with the native polar cod (Boreogadus saida) in the Arctic waters around Svalbard, Norway. Here, we studied light/dark adaptative optical plasticity of their eye lenses by exposing fish to bright light during the polar night. Schlieren photography, high-definition laser scanning and ray tracing were used to determine the optical properties of excised crystalline lenses. Both species have multifocal lenses, an optical adaptation for improved color vision. In polar cod, the optical properties of the lens were independent of light exposure. In the more southern Atlantic cod, the optical properties of the lens changed within hours upon exposure to light, even after months of darkness. Such fast optical adjustment has previously only been shown in a tropical cichlid. During the polar night the Atlantic cod lens seems to be unregulated and dysfunctional since it had an unsuitable focal length and severe spherical aberration. We present a system, to our knowledge unique, for studying visual plasticity on different timescales in relation to evolutionary history and present the first study on the polar cod visual system.

  17. Electron Lens Construction for the Integrable Optics Test Accelerator at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    McGee, Mike [Fermilab; Carlson, Kermit [Fermilab; Nobrega, Lucy [Fermilab; Stancari, Giulio [Fermilab; Valishev, Alexander [Fermilab

    2016-06-01

    The Integrable Optics Test Accelerator (IOTA) is proposed for operation at Fermilab. The goal of IOTA is to create practical nonlinear accelerator focusing systems with a large frequency spread and stable particle motion. The IOTA is a 40 m circumference, 150 MeV (e-), 2.5 MeV (p⁺) diagnostic test ring. Construction of an electron lens for IOTA is necessary for both electron and proton operation. Components required for the Electron Lens design include; a 0.8 T conventional water-cooled main solenoid, and magnetic bending and focusing elements. The foundation of the design relies on repurposing the Fermilab Tevatron Electron Lens II (TELII) gun and collector under ultra-high vacuum (UHV) conditions.

  18. Linear and nonlinear optical properties of a hydrogenic donor in lens-shaped quantum dots

    International Nuclear Information System (INIS)

    Vahdani, M.R.K.; Rezaei, G.

    2009-01-01

    Optical transitions in a Lens-Shaped Quantum Dot (LSD) are investigated in the presence of a hydrogenic impurity. The electronic wave functions are obtained analytically and the energy eigenvalues are calculated numerically. The density matrix formulation with the intersubband relaxation are used to evaluate the (linear and third order nonlinear) absorption coefficient (AC) and the change in the refractive indices (RI) analytically. The effect of the size of the LSD and optical intensity on the AC and RI are investigated. It is found that AC and RI are strongly affected by the optical intensity and the size of the LSD.

  19. Optical quality and vision with iris-coloring soft contact lenses.

    Science.gov (United States)

    Ortiz, Carolina; Jiménez, Raimundo

    2014-05-01

    To study the influence of iris-coloring soft contact lenses, designed for changing apparent iris color, on optical quality and vision. Eighty subjects were included in this study. All participants were classified as emmetropic, with monocular best-corrected visual acuity of 20/20 or better. For 40 subjects, we measured the optical quality (aberrations, the Strehl ratio, and the objective scattering index) and visual performance before and after wearing the cosmetic soft contact lenses. We also measured the optical quality and visual performance for the other 40 subjects but with a different kind of lens (fantasy soft contact lenses). Iris-coloring soft contact lenses significantly increased coma-like and total higher-order aberrations and objective scattering index (p Iris-coloring soft contact lenses deteriorate the optical quality and worsen the contrast sensitivity function. Iris-coloring soft contact lens wearers should be informed about the effects on optical quality and visual function.

  20. Common path ball lens probe for optical coherence tomography (Conference Presentation)

    Science.gov (United States)

    Singh, Kanwarpal; Yamada, Daisuke; Tearney, Guillermo J.

    2016-02-01

    Background: Common path probes are highly desirable for optical coherence tomography (OCT) as they reduce system complexity and cost. In this work we report an all-fiber common path side viewing monolithic probe for coronary artery imaging. Methods: Our common path probe was designed for spectrometer based Fourier domain OCT at 1310 nm wavelength. Light from the fiber expands in the coreless fiber region and then focussed by the ball lens. Reflection from ball lens-air interface served as reference signal. The monolithic ball lens probe was assembled within a 560 µmouter diameter drive shaft which was attached to a rotary junction. The drive shaft was placed inside an outer, transparent sheath of 800 µm diameter. Results: With a source input power of 25 mW, we could achieve sensitivity of 100.5 dB. The axial resolution of the system was found to be 15.6 µm in air and the lateral resolution (full width half maximum) was approximately 49 µm. As proof of principal, images of skin acquired using this probe demonstrated clear visualization of the stratum corneum, epidermis, and papillary dermis, along with sweat ducts. Conclusion: In this work we have demonstrated a monolithic, ball lens common, path probe for OCT imaging. The designed ball lens probe is easy to fabricate using a laser splicer. Based on the features and capability of common path probes to provide a simpler solution for OCT, we believe that this development will be an important enhancement for certain types of catheters.

  1. Optical implementation of multifocal programmable lens with single and multiple axes

    Science.gov (United States)

    Romero, Lenny A.; Millán, María S.; Pérez-Cabré, Elisabet

    2011-01-01

    In this work we analyse the generation of a diffractive optical element (DOE) consisting of a multifocal Fresnel lens by means of an LCoS (liquid cristal on silicon) spatial light modulator (SLM). The multifocal lens is composed of a set of lenses of different focal length that share a common optical axis (coaxial combination) or have different axes in parallel (multi-axis combination). For both configurations, we present several ways to combine the phase distributions for three lenses with different focal lengths (f1, f2, f3), into a single-phase distribution addressed to the SLM. Numerical simulations were carried out along with the experimental analysis to corroborate the results.

  2. Objective lens

    Science.gov (United States)

    Olczak, Eugene G. (Inventor)

    2011-01-01

    An objective lens and a method for using same. The objective lens has a first end, a second end, and a plurality of optical elements. The optical elements are positioned between the first end and the second end and are at least substantially symmetric about a plane centered between the first end and the second end.

  3. Application of fluidic lens technology to an adaptive holographic optical element see-through autophoropter

    Science.gov (United States)

    Chancy, Carl H.

    A device for performing an objective eye exam has been developed to automatically determine ophthalmic prescriptions. The closed loop fluidic auto-phoropter has been designed, modeled, fabricated and tested for the automatic measurement and correction of a patient's prescriptions. The adaptive phoropter is designed through the combination of a spherical-powered fluidic lens and two cylindrical fluidic lenses that are orientated 45o relative to each other. In addition, the system incorporates Shack-Hartmann wavefront sensing technology to identify the eye's wavefront error and corresponding prescription. Using the wavefront error information, the fluidic auto-phoropter nulls the eye's lower order wavefront error by applying the appropriate volumes to the fluidic lenses. The combination of the Shack-Hartmann wavefront sensor the fluidic auto-phoropter allows for the identification and control of spherical refractive error, as well as cylinder error and axis; thus, creating a truly automated refractometer and corrective system. The fluidic auto-phoropter is capable of correcting defocus error ranging from -20D to 20D and astigmatism from -10D to 10D. The transmissive see-through design allows for the observation of natural scenes through the system at varying object planes with no additional imaging optics in the patient's line of sight. In this research, two generations of the fluidic auto-phoropter are designed and tested; the first generation uses traditional glass optics for the measurement channel. The second generation of the fluidic auto-phoropter takes advantage of the progress in the development of holographic optical elements (HOEs) to replace all the traditional glass optics. The addition of the HOEs has enabled the development of a more compact, inexpensive and easily reproducible system without compromising its performance. Additionally, the fluidic lenses were tested during a National Aeronautics Space Administration (NASA) parabolic flight campaign, to

  4. Development and characterization of monolithic multilayer Laue lens nanofocusing optics

    Energy Technology Data Exchange (ETDEWEB)

    Nazaretski, E.; Xu, W., E-mail: weihexu@bnl.gov; Bouet, N.; Zhou, J.; Yan, H.; Huang, X.; Chu, Y. S. [Brookhaven National Laboratory, Upton, New York 11973 (United States)

    2016-06-27

    We have developed an experimental approach to bond two independent linear Multilayer Laue Lenses (MLLs) together. A monolithic MLL structure was characterized using ptychography at 12 keV photon energy, and we demonstrated 12 nm and 24 nm focusing in horizontal and vertical directions, respectively. Fabrication of 2D MLL optics allows installation of these focusing elements in more conventional microscopes suitable for x-ray imaging using zone plates, and opens easier access to 2D imaging with high spatial resolution in the hard x-ray regime.

  5. Development and characterization of monolithic multilayer Laue lens nanofocusing optics

    Energy Technology Data Exchange (ETDEWEB)

    Nazaretski, E.; Xu, W.; Bouet, N.; Zhou, J.; Yan, H.; Huang, X.; Chu, Y. S.

    2016-06-27

    We have developed an experimental approach to bond two independent linear Multilayer Laue Lenses (MLLs) together. A monolithic MLL structure was characterized using ptychography at 12 keV photon energy, and we demonstrated 12 nm and 24 nm focusing in horizontal and vertical directions, respectively. Fabrication of 2D MLL optics allows installation of these focusing elements in more conventional microscopes suitable for x-ray imaging using zone plates, and opens easier access to 2D imaging with high spatial resolution in the hard x-ray regime.

  6. Thermal lens and all optical switching of new organometallic compound doped polyacrylamide gel

    Science.gov (United States)

    Badran, Hussain Ali

    In this work thermal lens spectrometry (TLS) is applied to investigate the thermo-optical properties of new organometallic compound containing azomethine group, Dichloro bis [2-(2-hydroxybenzylideneamino)-5-methylphenyl] telluride platinum(II), doped polyacrylamide gel using transistor-transistor logic (TTL) modulated cw 532 nm laser beam as an excitation beam modulated at 10 Hz frequency and probe beam wavelength 635 nm at 14 mW. The technique is applied to determine the thermal diffusivities, ds/dT and the linear thermal expansion coefficient of the sample. All-optical switching effects with low background and high stability are demonstrated.

  7. Focusing on optic tectum circuitry through the lens of genetics

    Directory of Open Access Journals (Sweden)

    Nevin Linda M

    2010-09-01

    Full Text Available Abstract The visual pathway is tasked with processing incoming signals from the retina and converting this information into adaptive behavior. Recent studies of the larval zebrafish tectum have begun to clarify how the 'micro-circuitry' of this highly organized midbrain structure filters visual input, which arrives in the superficial layers and directs motor output through efferent projections from its deep layers. The new emphasis has been on the specific function of neuronal cell types, which can now be reproducibly labeled, imaged and manipulated using genetic and optical techniques. Here, we discuss recent advances and emerging experimental approaches for studying tectal circuits as models for visual processing and sensorimotor transformation by the vertebrate brain.

  8. Development of a Fresnel lens for cold neutrons based on neutron refractive optics

    CERN Document Server

    Oku, T; Moriyasu, S; Yamagata, Y; Ohmori, H; Takizawa, Y; Shimizu, H M; Hirota, T; Kiyanagi, Y; Ino, T; Furusaka, M; Suzuki, J

    2001-01-01

    We have developed compound refractive lenses (CRLs) for cold neutrons, which are made of vitreous silica and have an effective potential of (90.1-2.7x10 sup - sup 4 i) neV. In the case of compound refractive optics, neutron absorption by the material deteriorates lens performance. Thus, to prevent an increase in neutron absorption with increasing beam size, we have developed Fresnel lenses using the electrolytic in-process dressing grinding technique. The lens characteristics were carefully investigated with experimental and numerical simulation studies. The lenses functioned as a neutron focusing lens, and the focal length of 14 m was obtained with a 44-element series of the Fresnel lenses for 10 A neutrons. Moreover, good neutron transmission of 0.65 for 15 A neutrons was obtained due to the shape effect. According to comprehensive analysis of the obtained results, it is possible to realize a CRL for practical use by choosing a suitable lens shape and material.

  9. A Two-Stage Taguchi Design ExampleImage Quality Promotion in Miniature Camera/Cell-Phone Lens

    Directory of Open Access Journals (Sweden)

    Luke K. Wang

    2012-07-01

    Full Text Available A simple, practical manufacturing process, integrating manufacturing capability-oriented design (MCOD philosophy and Taguchi’s method, is presented to tackle the high resolution miniature camera/cell phone lens issues at the manufacturing phase. Meanwhile, we also use optical software to create an analytical simulation model to investigate the quality characteristics due to lens’ thickness, eccentricity, surface profile, and air lens’ gap; a single quality characteristics expressed in terms of modulation transfer function (MTF is defined. Optimal combination of process parameters in experimental scenario using Taguchi’s method is performed, and the results are judged and analyzed by the indices of signal-to-noise ratio (S/N and the analysis of variance (ANOVA. The key idea of the two-stage design is to utilize optical software to conduct the sensitivity analysis of MTF first; an analytical model, dependent on actual process parameters at manufacturing stage, is constructed next; and finally by substituting these outputs from the analytical model back to the optical software to verify the design criterion and do the modifications. By minimizing both the theoretical errors at design stage and the complexity in the manufacturing process, we are able to seeking for the most economical solution, simultaneously attain the optimal/suboptimal combination of process parameters or control factors in lens manufacturing issue.

  10. Assessment of a liquid lens enabled in vivo optical coherence microscope.

    Science.gov (United States)

    Murali, Supraja; Meemon, Panomsak; Lee, Kye-Sung; Kuhn, William P; Thompson, Kevin P; Rolland, Jannick P

    2010-06-01

    The optical aberrations induced by imaging through skin can be predicted using formulas for Seidel aberrations of a plane-parallel plate. Knowledge of these aberrations helps to guide the choice of numerical aperture (NA) of the optics we can use in an implementation of Gabor domain optical coherence microscopy (GD-OCM), where the focus is the only aberration adjustment made through depth. On this basis, a custom-designed, liquid-lens enabled dynamic focusing optical coherence microscope operating at 0.2 NA is analyzed and validated experimentally. As part of the analysis, we show that the full width at half-maximum metric, as a characteristic descriptor for the point spread function, while commonly used, is not a useful metric for quantifying resolution in non-diffraction-limited systems. Modulation transfer function (MTF) measurements quantify that the liquid lens performance is as predicted by design, even when accounting for the effect of gravity. MTF measurements in a skinlike scattering medium also quantify the performance of the microscope in its potential applications. To guide the fusion of images across the various focus positions of the microscope, as required in GD-OCM, we present depth of focus measurements that can be used to determine the effective number of focusing zones required for a given goal resolution. Subcellular resolution in an onion sample, and high-definition in vivo imaging in human skin are demonstrated with the custom-designed and built microscope.

  11. Diamond Machining of Optical Structured Surfaces Using a Circular Fresnel Lens as an Example

    Directory of Open Access Journals (Sweden)

    S. V. Grubyi

    2017-01-01

    Full Text Available Components of optical systems for various purposes include optical elements with structured surfaces, i.e. linear and circular Fresnel lenses. The objective of the conducted studies is to analyse design parameters and technological development of modes and conditions to ensure manufacturing circular Fresnel lenses with specified technology requirements.The subject of the study is a circular Fresnel lens, which has a thickness of 2 mm and a diameter of 76.7 mm; its processed profile consists of 126 concentric rings with a valley pitch equal to 0.3 mm. The profile depth of the rings varies from 2.1μm to 337.4μm, with the profile angle varying from 0.406 ° to 48.361 °. The lens material is polymethyl methacrylate (PMMA - a tough amorphous polymer, which has high transparency, weather resistance, good physical-mechanical and electrical insulating properties.The article presents the results of applied research related to diamond machining of a Fresnel circular lens. Substantiates that there is a need to use an ultra-precise machine for lens processing and gives its main technical characteristics.The design features and recommended domestic and foreign diamond mono-crystalline cutters for preliminary and finishing processing of structured surfaces, including Fresnel lenses are analysed.The technology of diamond edge cutting machining of lenses is proposed, the modes and conditions of diamond turning to exclude finning are given.The results of metrological control have confirmed the requirements for the profile accuracy and the roughness of surfaces machined. The JSC "VNIIINSTRUMENT" has implemented the developed technology on the ultra-precise specialised NC machine and recommended its use in machining the structured plexiglass surfaces of various sizes for different purposes.

  12. The research on surface characteristics of optical lens by 3D printing technique and precise diamond turning technique

    Science.gov (United States)

    Huang, Chien-Yao; Chang, Chun-Ming; Ho, Cheng-Fong; Lee, Tai-Wen; Lin, Ping-Hung; Hsu, Wei-Yao

    2017-06-01

    The advantage of 3D printing technique is flexible in design and fabrication. Using 3D printing technique, the traditional manufacturing limitations are not considered. The optical lens is the key component in an optical system. The traditional process to manufacture optical plastic lens is injection molding. However injection molding is only suitable for plastics lens, it cannot fabricate optical and mechanical components at same time. The assembly error of optical system can be reduced effectively with fabricating optical and mechanical components at same time. The process of printing optical and mechanical components simultaneously is proposed in previous papers, but the optical surface of printing components is not transparent. If we increase the transmittance of the optical surface, the printing components which fabricated by 3D printing process could be high transmission. Therefore, precise diamond turning technique has been used to turning the surface of 3D printing optical lens in this paper. The precise diamond turning techniques could process surfaces of components to meet the requirements of optical system. A 3D printing machine, Stratasys Connex 500, and a precise diamond turning machine, Precitech Freeform705XG, have been used in this paper, respectively. The dimension, roughness, transmission and printing types of 3D printing components have been discussed in this paper. After turning and polishing process, the roughness of 3D printing component is below 0.05 μm and the transmittance increase above 80 %. This optical module can be used in hand-held telescope and other system which need lens and special mechanical structure fabricated simultaneously.

  13. Imaging properties of the light sword optical element used as a contact lens in a presbyopic eye model.

    Science.gov (United States)

    Petelczyc, K; Bará, S; Lopez, A Ciro; Jaroszewicz, Z; Kakarenko, K; Kolodziejczyk, A; Sypek, M

    2011-12-05

    The paper analyzes the imaging properties of the light sword optical element (LSOE) applied as a contact lens to the presbyopic human eye. We performed our studies with a human eye model based on the Gullstrand parameterization. In order to quantify the discussion concerning imaging with extended depth of focus, we introduced quantitative parameters characterizing output images of optotypes obtained in numerical simulations. The quality of the images formed by the LSOE were compared with those created by a presbyopic human eye, reading glasses and a quartic inverse axicon. Then we complemented the numerical results by an experiment where a 3D scene was imaged by means of the refractive LSOE correcting an artificial eye based on the Gullstrand model. According to performed simulations and experiments the LSOE exhibits abilities for presbyopia correction in a wide range of functional vision distances.

  14. Fiber-optic Raman probe couples ball lens for depth-selected Raman measurements of epithelial tissue

    OpenAIRE

    Mo, Jianhua; Zheng, Wei; Huang, Zhiwei

    2010-01-01

    In this study, we present a fiber-optic ball lens Raman probe design for improving depth-selected Raman measurements of epithelial tissue. The Monte Carlo simulation results show that tissue Raman collection efficiency can be improved by properly selecting the refractive index and the diameter of the ball lens for the Raman probe design and the depth-selectivity of Raman measurements can also be improved by either increasing the refractive index or reducing the diameter of the ball lens. An a...

  15. Ball lens coupled fiber-optic probe for depth-resolved spectroscopy of epithelial tissue.

    Science.gov (United States)

    Schwarz, Richard A; Arifler, Dizem; Chang, Sung K; Pavlova, Ina; Hussain, Insiya A; Mack, Vivian; Knight, Bob; Richards-Kortum, Rebecca; Gillenwater, Ann M

    2005-05-15

    A ball lens coupled fiber-optic probe design is described for depth-resolved measurements of the fluorescence and reflectance properties of epithelial tissue. A reflectance target, fluorescence targets, and a two-layer tissue phantom consisting of fluorescent microspheres suspended in collagen are used to characterize the performance of the probe. Localization of the signal to within 300 microm of the probe tip is observed by use of reflectance and fluorescence targets in air. Differential enhancement of the fluorescence signal from the top layer of the two-layer tissue phantom is observed.

  16. The influence of the dose calculation resolution of VMAT plans on the calculated dose for eye lens and optic apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jong Min; Park, So Yeon; Kim, Jung In; Kim, Jin Ho [Dept. of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of); Wu, Hong Gyun [Dept. of Radiation Oncology, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2015-10-15

    Since those organs are small in volume, dose calculation for those organs seems to be more susceptible to the calculation grid size in the treatment planning system (TPS). Moreover, since they are highly radio-sensitive organs, especially eye lens, they should be considered carefully for radiotherapy. On the other hand, in the treatment of head and neck (H and N) cancer or brain tumor that generally involves radiation exposure to eye lens and optic apparatus, intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT) techniques are frequently used because of the proximity of various radio-sensitive normal organs to the target volumes. Since IMRT and VMAT can deliver prescription dose to target volumes while minimizing dose to nearby organs at risk (OARs) by generating steep dose gradients near the target volumes, high dose gradient sometimes occurs near or at the eye lenses and optic apparatus. In this case, the effect of dose calculation resolution on the accuracy of calculated dose to eye lens and optic apparatus might be significant. Therefore, the effect of dose calculation grid size on the accuracy of calculated doses for each eye lens and optic apparatus was investigated in this study. If an inappropriate calculation resolution was applied for dose calculation of eye lens and optic apparatus, considerable errors can be occurred due to the volume averaging effect in high dose gradient region.

  17. Improvement of optical imaging resolution by a negative refraction photonic crystal with a solid immersion lens

    International Nuclear Information System (INIS)

    Tseng, M.-C.; Chen, L.-W.; Liu, C.-Y.

    2008-01-01

    Photonic crystals (PCs) have many potential applications because of their ability to control light-wave propagation. We have investigated the solid immersion lens (SIL) technology in imaging system based on negative refraction PCs and analyzed the influence of refractive index and geometric parameters of SIL on imaging resolution. In the finite element method calculation, the resolution of our optical system has improved greatly. The high performance of imaging resolution was achieved with shorter radius and larger refractive index of SIL. Furthermore, the effects of the three kinds of SILs at the same radius were analyzed. Such a mechanism of negative refraction PCs and SILs should open up a new application for designing components in optical imaging systems

  18. Design and experimental validation of novel 3D optical scanner with zoom lens unit

    Science.gov (United States)

    Huang, Jyun-Cheng; Liu, Chien-Sheng; Chiang, Pei-Ju; Hsu, Wei-Yan; Liu, Jian-Liang; Huang, Bai-Hao; Lin, Shao-Ru

    2017-10-01

    Optical scanners play a key role in many three-dimensional (3D) printing and CAD/CAM applications. However, existing optical scanners are generally designed to provide either a wide scanning area or a high 3D reconstruction accuracy from a lens with a fixed focal length. In the former case, the scanning area is increased at the expense of the reconstruction accuracy, while in the latter case, the reconstruction performance is improved at the expense of a more limited scanning range. In other words, existing optical scanners compromise between the scanning area and the reconstruction accuracy. Accordingly, the present study proposes a new scanning system including a zoom-lens unit, which combines both a wide scanning area and a high 3D reconstruction accuracy. In the proposed approach, the object is scanned initially under a suitable low-magnification setting for the object size (setting 1), resulting in a wide scanning area but a poor reconstruction resolution in complicated regions of the object. The complicated regions of the object are then rescanned under a high-magnification setting (setting 2) in order to improve the accuracy of the original reconstruction results. Finally, the models reconstructed after each scanning pass are combined to obtain the final reconstructed 3D shape of the object. The feasibility of the proposed method is demonstrated experimentally using a laboratory-built prototype. It is shown that the scanner has a high reconstruction accuracy over a large scanning area. In other words, the proposed optical scanner has significant potential for 3D engineering applications.

  19. Fiber-optic Raman probe couples ball lens for depth-selected Raman measurements of epithelial tissue.

    Science.gov (United States)

    Mo, Jianhua; Zheng, Wei; Huang, Zhiwei

    2010-06-28

    In this study, we present a fiber-optic ball lens Raman probe design for improving depth-selected Raman measurements of epithelial tissue. The Monte Carlo simulation results show that tissue Raman collection efficiency can be improved by properly selecting the refractive index and the diameter of the ball lens for the Raman probe design and the depth-selectivity of Raman measurements can also be improved by either increasing the refractive index or reducing the diameter of the ball lens. An appropriate arrangement of the Raman probe-tissue distance can also optimize the collection efficiency for depth-resolved Raman measurements. Experimental evaluation of a ball lens Raman probe design on a two-layer tissue phantom confirms the potential of the ball lens Raman probe design for efficient depth-selected measurement on epithelial tissue. This work suggests that the fiber-optic Raman probe coupled with a ball lens can facilitate the depth-selected Raman measurements of epithelial tissue, which may improve the diagnosis of epithelial precancer and early cancer at the molecular level.

  20. Restoring in-phase emissions from non-planar radiating elements using a transformation optics based lens

    Energy Technology Data Exchange (ETDEWEB)

    Yi, Jianjia [IEF, CNRS, UMR 8622, Université Paris-Sud, 91405 Orsay Cedex (France); Burokur, Shah Nawaz, E-mail: shah-nawaz.burokur@u-psud.fr; Lustrac, André de [IEF, CNRS, UMR 8622, Université Paris-Sud, 91405 Orsay Cedex (France); Université Paris-Ouest, 92410 Ville d' Avray (France); Piau, Gérard-Pascal [AIRBUS Group Innovations, 92150 Suresnes (France)

    2015-07-13

    The broadband directive in-phase emission from an array of sources conformed cylindrically is numerically and experimentally reported. Such manipulation is achieved through the use of a lens designed by transformation optics concept. The all-dielectric lens prototype is realized through three-dimensional (3D) polyjet printing and presents a graded refractive index. A microstrip antenna array fabricated using standard lithography techniques and conformed on a cylindrical surface is used as TE-polarized wave launcher for the lens. To experimentally demonstrate the broadband focusing properties and in-phase directive emissions, both the far-field radiation patterns and the near-field distributions have been measured. Experimental measurements agreeing qualitatively with numerical simulations validate the proposed lens and open the way to inexpensive all-dielectric microwave lenses for beam forming and collimation.

  1. A wide-angle gradient index optical model of the crystalline lens and eye of the octopus.

    Science.gov (United States)

    Jagger, W S; Sands, P J

    1999-08-01

    Cephalopods and fish have had no common ancestor since the Cambrian, and their eyes are a classic example of convergent evolution. The octopus has no cornea, and immerson renders the trout cornea optically ineffective. As a result, the nearly spherical lens is responsible for all refraction in these eyes. In spite of the fact that the octopus lens consists of two joined parts, while the trout lens consists of one part, we show here that their optical properties are very similar. An index gradient bends rays within these lenses, adding power and correcting spherical aberration. High spherical symmetry in both lenses strongly reduces other monochromatic aberrations and yields a wide field of vision, advantageous in attack and evasion. The octopus Mattheissen's ratio, 2.83, an inverse measure of light-gathering power, lies above the trout value of 2.38 but within the range of values reported for fish. Strong uncorrected longitudinal chromatic aberration is nearly identical in both animals as a result of similar lens protein optical properties, and will limit resolution. We discuss how animal lifestyle requirements and lens material properties influence the design of these eyes.

  2. Preoperative anterior segment optical coherence tomography as a predictor of postoperative phakic intraocular lens position.

    Science.gov (United States)

    Fallah Tafti, Mohammad Reza; Moghadam, Reza Soltani; Beheshtnejad, Amir Houshang; Jabbarvand, Mahmoud; Mohebi, Masoomeh; Zarei-Ghanavati, Mehran

    2013-12-01

    To evaluate anterior segment optical coherence tomography (AS-OCT) in the preoperative simulation of postoperative iris-fixated phakic intraocular lens (pIOL) position in the anterior chamber. Farabi Eye Research Center, Department of Ophthalmology, Tehran University of Medical Sciences, Tehran, Iran. Case series. Using AS-OCT, the pIOL position was simulated preoperatively in 2 ways and compared with the actual postoperative pIOL position. For preoperative evaluations, the simulator was placed on the posterior pigmented epithelium of the iris. Then, the simulation was performed with the simulator placed in the middle of the iris tissue. The following distances were measured: from the center of the pIOL to the endothelium, from the edge of the pIOL to the endothelium, and from the posterior surface of the pIOL to the crystalline lens. The study examined 26 eyes (16 patients). Although all distances in both simulation methods (except the lens vault in the first method of simulation) were highly correlated (all P<.009), only the results with the simulator placed in the middle of the iris tissue were not statistically different from the corresponding postoperative measurements (P=.209 and P=.564 for distance from endothelium to the center and the pIOL edge, respectively). Using the pIOL template of the AS-OCT system for preoperative simulation of iris-fixated pIOLs improved the criteria for patient selection for implantation of these pIOLs. The simulator should be placed in the middle of the iris tissue for preoperative simulation. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  3. Evaluation of visual quality of spherical and aspherical intraocular lenses by Optical Quality Analysis System

    Directory of Open Access Journals (Sweden)

    Yan Chen

    2017-06-01

    Full Text Available AIM: To evaluate the impact of spherical and aspherical intraocular lenses on the postoperative visual quality of age-related cataract patients using Optical Quality Analysis System (OQAS. METHODS: Seventy-four eyes with age-related cataracts were randomly divided into spherical and aspherical lens implantation groups. Best-corrected visual acuity (BCVA was measured preoperatively, one day, one week, two weeks, one month and two months after surgery. A biometric systems analysis using the OQAS objective scattering index (OSI was performed. RESULTS: There were no significant differences in visual acuity (P>0.05 before and after spherical and aspheric lens implantation. There was a negative linear correction between the OSI value and BCVA (r=-0.634, P=0.000, and positive corrections between the OSI value and the lens LOCUS III value of nucleus color (NC, nucleus opacity (NO, cortex (C and posterior lens capsular (P (r=0.704, P=0.000; r=0.514, P=0.000; r=0.276, P=0.020; r=0.417, P=0.000, respectively. OSI values of spherical vs aspherical lenses were 11.5±3.6 vs 11.8±3.4, 4.1±0.9 vs 3.3±0.8, 3.5±0.9 vs 2.7±0.7, 3.3±0.8 vs 2.6±0.7, 3.2±0.7 vs 2.5±0.8, and 3.2±0.8 vs 2.5±0.8 before and 1d, 1, 2wk, 1 and 2mo after surgery, respectively. All time points varied significantly (P<0.01 between the two groups. CONCLUSION: Aspherical IOLs does not significantly affect visual acuity compared with spherical IOLs. The OSI value, was significantly lower in the aspherical lens group compared with the spherical lens. This study shows that objective visual quality of aspheric IOLs is better than that of the spherical lens by means of OQAS biological measurement method.

  4. Two-step technique for posterior optic buttonholing of intraocular lens.

    Science.gov (United States)

    Agarwal, Tushar; Jhanji, Vishal; Singh, Digvijay; Khokhar, Sudarshan

    2014-04-01

    This study aims to describe a two-step surgical technique for placement of a posterior chamber intraocular lens (IOL) in cases with crystalline lens subluxation resulting from non-progressive zonular dialysis. The first stage entails a phacoemulsification with creation of a 4-mm posterior capsular opening using an automated vitrector. The second stage performed 6 weeks later includes an anterior vitrectomy and injection of a foldable three-piece IOL in the sulcus. The haptics of IOL are positioned in the sulcus while the optic is pushed behind the posterior capsular opening therefore "buttonholing" the IOL. Seven eyes of seven patients with posttraumatic zonular dialysis were operated using this technique. Follow-up of all cases revealed a well-centered IOL with good postoperative visual acuity (20/20 to 20/80). Our two-stage surgical technique precludes the insertion of capsular tension ring in cases with non-progressive zonular dialysis. The technique is recommended in the presence of less than or equal to 6 clock hours of zonular dialysis with preexisting posterior capsular tear or herniation of vitreous in the anterior chamber.

  5. Image dissector photocathode solar damage test program. [solar radiation shielding using a fast optical lens

    Science.gov (United States)

    Smith, R. A.

    1977-01-01

    Image dissector sensors of the same type which will be used in the NASA shuttle star tracker were used in a series of tests directed towards obtaining solar radiation/time damage criteria. Data were evaluated to determine the predicted level of operability of the star tracker if tube damage became a reality. During the test series a technique for reducing the solar damage effect was conceived and verified. The damage concepts are outlined and the test methods and data obtained which were used for verification of the technique's feasibility are presented. The ability to operate an image dissector sensor with the solar image focussed on the photocathode by a fast optical lens under certain conditions is feasible and the elimination of a mechanical protection device is possible.

  6. Comparison of intraocular lens power calculation using a standard ultrasonic biometer and a new optical biometer

    Directory of Open Access Journals (Sweden)

    Faruk Kaya

    2016-05-01

    Full Text Available AIM:To compare the intraocular lens(IOLpower calculations and refractive outcomes obtained with a new optical biometer and standard ultrasonic biometer in phacoemulsification surgery.METHODS:Thirty-seven eyes of 37 cataract patients who underwent phacoemulsification with IOL implantation were included in this prospective comparative study. The same operator performed biometer measurements in eyes with cataract using a new optical biometer(Aladdinand a standard ultrasonic biometer(Sonomed AB 5500. Biometric parameters; axial length(AL, keratometric(Kreadings, anterior chamber depth(ACDand IOL power obtained by two devices were recorded. Postoperative actual refractive errors and errors predicted by two devices according to SRK/T formula were analyzed. The mean estimation error(EE, mean absolute estimation error(AEEand the biometric parameters obtained by two biometers were compared.RESULTS:The AL measured by Aladdin(23.45±0.73 mmwas significantly longer than AL by ultrasonic biometer(23.2±0.75 mm(P=0.01. The mean EE and AEE values obtained by Aladdin were significantly smaller than the values by ultrasonic biometer(P=0.0006 and 0.03 respectively. The higher percentage of eyes within ±0.5 and ±1.00 D of target refraction was also found by using Aladdin(67% and 97%.CONCLUSION:The Aladdin optical biometer showed better accuracy and yielded better refractive outcomes compared with ultrasonic biometer.

  7. Optical Image Encryption Using Devil’s Vortex Toroidal Lens in the Fresnel Transform Domain

    Directory of Open Access Journals (Sweden)

    Hukum Singh

    2015-01-01

    Full Text Available We have carried out a study of optical image encryption in the Fresnel transform (FrT domain, using a random phase mask (RPM in the input plane and a phase mask based on devil’s vortex toroidal lens (DVTL in the frequency plane. The original images are recovered from their corresponding encrypted images by using the correct parameters of the FrT and the parameters of DVTL. The use of a DVTL-based structured mask enhances security by increasing the key space for encryption and also aids in overcoming the problem of axis alignment associated with an optical setup. The proposed encryption scheme is a lensless optical system and its digital implementation has been performed using MATLAB 7.6.0 (R2008a. The scheme has been validated for a grayscale and a binary image. The efficacy of the proposed scheme is verified by computing mean-squared-error (MSE between the recovered and the original images. We have also investigated the scheme’s sensitivity to the encryption parameters and examined its robustness against occlusion and noise attacks.

  8. Optical Time-Division Multiplexing of 10 Gbit/s Ethernet Signals Synchronized by All-Optical Signal Processing Based on a Time-Lens

    DEFF Research Database (Denmark)

    Areal, Janaina Laguardia

    This Thesis presents 3 years work of an optical circuit that performs both pulse compression and frame synchronization and retiming. Our design aims at directly multiplexing several 10G Ethernet data packets (frames) to a high-speed OTDM link. This scheme is optically transparent and does...... pulse compression, as well. The overall design is: (1) Pulses are converted from NRZ to RZ; (2) pulses are synchronized, retimed and further compressed at the specially designed time-lens; and (3) with adequate optical delays, frames from different input interfaces are added, with a simple optical...

  9. First Experience With the ICD 16.5 Mini-Scleral Lens for Optic and Therapeutic Purposes.

    Science.gov (United States)

    Suarez, Cyrielle; Madariaga, Virginie; Lepage, Benoît; Malecaze, Marie; Fournié, Pierre; Soler, Vincent; Galiacy, Stéphane; Mély, René; Cassagne, Myriam; Malecaze, François

    2018-01-01

    To evaluate the success rate, efficacy, and safety of the ICD 16.5 mini-scleral gas permeable (GP) contact lens. This prospective study included referred consecutive patients with irregular corneas and severe ocular surface disease (OSD) in treatment failure. All patients were fitted with the ICD 16.5 mini-scleral GP lens. Even though we had some limited experience with scleral lenses, it was our first experience with the ICD 16.5 mini-scleral GP lens. Efficacy was assessed by comparing best-corrected visual acuity (BCVA) with the mini-scleral lens to baseline BCVA. A subjective visual functioning questionnaire (comfort score, visual quality score, handling rating, and wearing time) was administered in a face-to-face structured interview. Thirty-nine eyes of 23 patients with a mean age of 43±16 years were included. Fitting indications were keratoconus (46%), post-penetrating keratoplasty (21%), other irregular astigmatism (15%), and severe OSD (18%). Twenty-five eyes (64%) were successfully fitted with an 18-month follow-up. The mini-scleral GP lens BCVA was 0.16 logarithm of the minimum angle of resolution (logMAR; 20/25) versus a baseline BCVA of 0.44 logMAR (20/63; Pscleral GP lens is an effective and safe alternative for managing challenging corneas in a therapeutic impasse.

  10. Easy and versatile adaptive optics setup with deformable lens for high-resolution microscopy

    Science.gov (United States)

    Pozzi, P.; Quintavalla, M.; Verstraete, H.; Bijlsma, H.; Bonora, S.; Verhaegen, M.

    2017-06-01

    It has been widely proven in literature that most optical microscopy techniques can greatly benefit from the application of adaptive optics correction of phase aberrations through an adaptive optical element, such as a deformable mirror or a spatial light modulator. However, adaptive optics is not yet widely adopted in the life sciences community, mostly due to the lack of adaptive commercial microscopy systems, and the inherent technical difficulty in modifying an existing microscopy setup to integrate an adaptive element, both on the software and hardware sides. We present a plug-and-play adaptive optics module for generic optical microscopes, based on a prototype refractive 18 actuators adaptive optical element, which can be inserted in any microscope between the objective and the microscope body. Correction is performed in a sensorless fashion, optimizing image quality metrics of the image presented to the user on screen. The results presented show how an end-user oriented commercial confocal laser scanning microscope (Leica SP5) can be upgraded with adaptive optics with minor hardware modifications, and no changes to the microscope control software.

  11. Investigation into surface interaction between the contact lens, the upper eyelid and cornea using optical coherence tomography

    Science.gov (United States)

    Morecroft, R.; Carré, M. J.; Lewis, R.; Mylon, P.; Matcher, S. J.; Toomey, P.; Goff, J. E.; Maiti, R.

    2017-02-01

    Background and Aim: Over 50% of the total 125 million contact lens users complain of discomforts due to contact lenses. The aim of the project is to understand the effect of contact lenses on the morphological parameters of cornea and eyelid surfaces. Methods and results: Five volunteers were recruited for this study (3 soft contact lens users and 2 non-users). The volunteers were imaged using a slit lamp and Optical Coherence Tomography (OCT) before and after a period of 6-7 hours. There was a significant increase in epidermal thickness of the eyelid for contact lens users compared to non-users. In addition, the upper eyelid roughness for contact lens users and non-users increased significantly. This might be due to deposition of particles from the eyelid during the wiping process. Conclusions: Contact lens usage does affect the morphological parameters of eyelid. OCT is a powerful tool to measure these morphological changes in the eye. However, more volunteers must be recruited to get a better understanding of these changes.

  12. Investigation of an optical method for determining the average radius of curvature of micro-optical lenticular lens arrays

    DEFF Research Database (Denmark)

    Iversen, Theis Faber Quist; Hanson, Steen Grüner; Kirkegaard, Peter

    2009-01-01

    variations that have arisen in the moulding process. The experimental results are compared with a model, based on the Fraunhofer approximation to the Huygens-Fresnel principle. Furthermore, the optical elements under investigation are probed using a scanning probe microscope. Hence, access to accurate......Micro-optical elements are of great importance in areas of optoelectronics and information processing. Establishing fast, reliable methods for characterization and quality control of these elements is important in order to maintain the optical performance in a high volume production process. We...... investigate an optical technique, applied to a polymer-based, injection moulded, lenticular array, but the method is also applicable for the tooling for these elements. The cylindrical lenses have feature sizes of 1-15 mu m. The method is based on observation of the intensity distribution, which can...

  13. Large depth of focus dynamic micro integral imaging for optical see-through augmented reality display using a focus-tunable lens.

    Science.gov (United States)

    Shen, Xin; Javidi, Bahram

    2018-03-01

    We have developed a three-dimensional (3D) dynamic integral-imaging (InIm)-system-based optical see-through augmented reality display with enhanced depth range of a 3D augmented image. A focus-tunable lens is adopted in the 3D display unit to relay the elemental images with various positions to the micro lens array. Based on resolution priority integral imaging, multiple lenslet image planes are generated to enhance the depth range of the 3D image. The depth range is further increased by utilizing both the real and virtual 3D imaging fields. The 3D reconstructed image and the real-world scene are overlaid using an optical see-through display for augmented reality. The proposed system can significantly enhance the depth range of a 3D reconstructed image with high image quality in the micro InIm unit. This approach provides enhanced functionality for augmented information and adjusts the vergence-accommodation conflict of a traditional augmented reality display.

  14. Measurement of nonlinear optical refraction of composite material based on sapphire with silver by Kerr-lens autocorrelation method.

    Science.gov (United States)

    Yu, Xiang-xiang; Wang, Yu-hua

    2014-01-13

    Silver nanoparticles synthesized in a synthetic sapphire matrix were fabricated by ion implantation using the metal vapor vacuum arc ion source. The optical absorption spectrum of the Ag: Al2O3 composite material has been measured. The analysis of the supercontinuum spectrum displayed the nonlinear refractive property of this kind of sample. Nonlinear optical refraction index was identified at 800 nm excitation using the Kerr-lens autocorrelation (KLAC) technique. The spectrum showed that the material possessed self-defocusing property (n(2) = -1.1 × 10(-15) cm(2)W). The mechanism of nonlinear refraction has been discussed.

  15. Knowledge-based optical system design

    Science.gov (United States)

    Nouri, Taoufik

    1992-03-01

    This work is a new approach for the design of start optical systems and represents a new contribution of artificial intelligence techniques in the optical design field. A knowledge-based optical-systems design (KBOSD), based on artificial intelligence algorithms, first order logic, knowledge representation, rules, and heuristics on lens design, is realized. This KBOSD is equipped with optical knowledge in the domain of centered dioptrical optical systems used at low aperture and small field angles. It generates centered dioptrical, on-axis and low-aperture optical systems, which are used as start systems for the subsequent optimization by existing lens design programs. This KBOSD produces monochromatic or polychromatic optical systems, such as singlet lens, doublet lens, triplet lens, reversed singlet lens, reversed doublet lens, reversed triplet lens, and telescopes. In the design of optical systems, the KBOSD takes into account many user constraints such as cost, resistance of the optical material (glass) to chemical, thermal, and mechanical effects, as well as the optical quality such as minimal aberrations and chromatic aberrations corrections. This KBOSD is developed in the programming language Prolog and has knowledge on optical design principles and optical properties. It is composed of more than 3000 clauses. Inference engine and interconnections in the cognitive world of optical systems are described. The system uses neither a lens library nor a lens data base; it is completely based on optical design knowledge.

  16. Study of the Photodegradation Process of Vitamin E Acetate by Optical Absorption, Fluorescence, and Thermal Lens Spectroscopy

    Science.gov (United States)

    Tiburcio-Moreno, J. A.; Marcelín-Jiménez, G.; Leanos-Castaneda, O. L.; Yanez-Limon, J. M.; Alvarado-Gil, J. J.

    2012-11-01

    The stability of vitamin E acetate exposed to ultraviolet (UV) light was studied using three spectroscopic methods. An ethanol solution of vitamin E acetate was treated with either UVC light (254 nm) or UVA light (366 nm) during a period of 10 min followed by a study of UV-Vis optical absorption, then by fluorescence spectroscopy excitation by UV radiation at either 290 nm or 368 nm and, finally the solution was studied by thermal lens spectroscopy. Immediately, the same solution of vitamin E acetate was subjected to the UV irradiation process until completion of six periods of irradiation and measurements. UVC light treatment induced the appearance of a broad absorption band in the range of 310 nm to 440 nm with maximum absorbance at 368 nm, which progressively grew as the time of the exposure to UVC light increases. In contrast, UVA light treatment did not affect the absorption spectra of vitamin E acetate. Fluorescence spectra of the vitamin E acetate (without UV light treatment) showed no fluorescence when excited with 368 nm while exciting with 290 nm, an intense and broad emission band (300 nm to 440 nm) with a maximum at 340 nm appeared. When vitamin E acetate was treated with UVC light, this emission band progressively decreased as the time of the UVC light irradiation grew. No signal from UV-untreated vitamin E acetate could be detected by the thermal lens method. Interestingly, as the time of the UVC light treatment increased, the thermal lens signal progressively grew. Additional experiments performed to monitor the time evolution of the process during continuous UVC treatment of the vitamin E acetate using thermal lens spectroscopy exhibited a progressive increase of the thermal lens signal reaching a plateau at about 8000 s. This study shows that the vitamin E acetate is stable when it is irradiated with UVA light, while the irradiation with UVC light induces the formation of photodegradation products. Interestingly, this photodegradation process using

  17. Scatter radiation dose at height of the lens and image quality in interventional cardiology

    International Nuclear Information System (INIS)

    Leguees, Fernando A. Leyton

    2016-01-01

    Cardiologist and other staff members receive high doses of scattered radiation. Cases of radiation-induced cataract among cardiology professionals have been reported in studies, estimates for the dose to eye lens ranged from 450 to 900 mSv per year (without ceiling suspended screen), over several years. Recent surveys regarding high prevalence of lens changes likely induced by radiation exposure suggest an urgent need for improved radiation safety and training, use of eye protection during catheterization procedures, and improved occupational dosimetry. In view of the evidence of radiation injuries, the ICRP recommends limiting the radiation dose to the lens to 20 mSv per year for occupational exposure. A system for optimizing the radiation exposure is the measurement of entrance surface air kerma (K a,e ) and kerma-area product (P KA ) for patient and scattered dose or dose rate at the position for the staff, under clinical working conditions using phantoms and defined technical factors. Correlating K a,e and P KA with the scatter dose, applying the attenuation factors protective devices can enable estimation of the lens doses for operators. The purpose of this work is: to study the possibility of establishing a procedure which is useful for scientific societies and the regulatory authority in the prevention and control of IOE dose and to control and improve the quality of procedures in interventional cardiology as an initiative to raise awareness and optimization of radiological protection. Measurements were taken in different cardiac laboratories. Clinical working conditions were reproduced during the experiments for the different hemodynamic angiographic projections and operating modes used in fluoroscopy and cine. A first K a,e rate reference proposal for the characterization of angiography for the different acquisition modes were 16; 35; 40 and 220 (mGy/min), respectively. Considering the typical PKA values to patient in interventional cardiology procedures

  18. Comparison of the biometric measurements obtained using noncontact optical biometers LenStar LS 900 and IOL Master V.5.

    Science.gov (United States)

    Kołodziejczyk, Wojciech; Gałecki, Tomasz; Łazicka-Gałecka, Monika; Szaflik, Jerzy

    2011-01-01

    Evaluation of the measurement accuracy using a new optical biometer LenStar LS 900 (Haag Strait) and comparison according to the IOL Master V.5 (Zeiss) device. In a prospective clinical study biometric measurements along with artificial lens power calculation using the LenStar LS 900 device were performed. A total number of 106 patients qualified for a cataract extraction procedure were included in the study. Measurements along with lens power calculation were repeated using the IOL Master V.5. device. Results were elaborated using Pearson's correlation and Bland-Altman plot. Measurements were performed in 204 eyes of 106 patients. Mean values and ranges of biometry results were as follows: 23.46 +/- 2.81 mm [20.79-29.80] for IOL Master, and 23.47 +/- 2.83 mm [20.79-29.86] for LenStar LS 900. In keratometry for flat meridian (K1) the following data was obtained: mean 43.24 +/- 3.22 D [range 38.27-47.94] for IOL Master and 42.44 +/- 3.15 D [38.27-47.94] for LenStar LS 900. For steep meridian (K2) the data obtained were 44.14 +/- 3.40 D; [39.29-49.13] and 43.27 +/- 3.34 D [38.61-48.4] respectively. The obtained calculation results for each eye were as follows: mean 21.23 +/- 8.07, [range 3.25-28.99] for Hagis formula, 21.14 +/- 6.90; [4.83-27.6] for SRK II, 21.04 +/- 7.78; [3.05-28.05] for SRK/T, 21.09 +/- 8.13; [2.43-28.61] for Holladay using IOL Master and 21.41 +/- 8.23; [2.99-29.15] for Haigis; 21.24 +/- 7.00; [4.6-27.71] for SRK II, 21.13 +/- 7.90; [2.76-28.18] for SRK/T; 21.09 +/- 8.13; [2.16-28.76] for Holladay using LenStar LS 900. The LenStar LS 900 device enables to perform accurate and repetitive biometric measurements and implant power calculations. Implant calculation results obtained using the LenStar LS 900 device are comparable to those achieved using the IOL Master V.5 device, which has been commonly accepted as standard for over a decade. The use of both devices is limited by significant lens opacification and posterior capsule calcification. In

  19. Objective-lens-free Fiber-based Position Detection with Nanometer Resolution in a Fiber Optical Trapping System.

    Science.gov (United States)

    Ti, Chaoyang; Ho-Thanh, Minh-Tri; Wen, Qi; Liu, Yuxiang

    2017-10-13

    Position detection with high accuracy is crucial for force calibration of optical trapping systems. Most existing position detection methods require high-numerical-aperture objective lenses, which are bulky, expensive, and difficult to miniaturize. Here, we report an affordable objective-lens-free, fiber-based position detection scheme with 2 nm spatial resolution and 150 MHz bandwidth. This fiber based detection mechanism enables simultaneous trapping and force measurements in a compact fiber optical tweezers system. In addition, we achieved more reliable signal acquisition with less distortion compared with objective based position detection methods, thanks to the light guiding in optical fibers and small distance between the fiber tips and trapped particle. As a demonstration of the fiber based detection, we used the fiber optical tweezers to apply a force on a cell membrane and simultaneously measure the cellular response.

  20. Development and Optical Testing of the Camera, Hand Lens, and Microscope Probe with Scannable Laser Spectroscopy (CHAMP-SLS)

    Science.gov (United States)

    Mungas, Greg S.; Gursel, Yekta; Sepulveda, Cesar A.; Anderson, Mark; La Baw, Clayton; Johnson, Kenneth R.; Deans, Matthew; Beegle, Luther; Boynton, John

    2008-01-01

    Conducting high resolution field microscopy with coupled laser spectroscopy that can be used to selectively analyze the surface chemistry of individual pixels in a scene is an enabling capability for next generation robotic and manned spaceflight missions, civil, and military applications. In the laboratory, we use a range of imaging and surface preparation tools that provide us with in-focus images, context imaging for identifying features that we want to investigate at high magnification, and surface-optical coupling that allows us to apply optical spectroscopic analysis techniques for analyzing surface chemistry particularly at high magnifications. The camera, hand lens, and microscope probe with scannable laser spectroscopy (CHAMP-SLS) is an imaging/spectroscopy instrument capable of imaging continuously from infinity down to high resolution microscopy (resolution of approx. 1 micron/pixel in a final camera format), the closer CHAMP-SLS is placed to a feature, the higher the resultant magnification. At hand lens to microscopic magnifications, the imaged scene can be selectively interrogated with point spectroscopic techniques such as Raman spectroscopy, microscopic Laser Induced Breakdown Spectroscopy (micro-LIBS), laser ablation mass-spectrometry, Fluorescence spectroscopy, and/or Reflectance spectroscopy. This paper summarizes the optical design, development, and testing of the CHAMP-SLS optics.

  1. Service quality and maturity of health care organizations through the lens of Complexity Leadership Theory.

    Science.gov (United States)

    Horvat, Ana; Filipovic, Jovan

    2018-02-01

    This research focuses on Complexity Leadership Theory and the relationship between leadership-examined through the lens of Complexity Leadership Theory-and organizational maturity as an indicator of the performance of health organizations. The research adopts a perspective that conceptualizes organizations as complex adaptive systems and draws upon a survey of opinion of 189 managers working in Serbian health organizations. As the results indicate a dependency between functions of leadership and levels of the maturity of health organizations, we propose a model that connects the two. The study broadens our understanding of the implications of complexity thinking and its reflection on leadership functions and overall organizational performance. The correlations between leadership functions and maturity could have practical applications in policy processing, thus improving the quality of outcomes and the overall level of service quality. © 2017 John Wiley & Sons, Ltd.

  2. Corrected electrostatic lens systems for ion beams

    International Nuclear Information System (INIS)

    Dalgish, R.L.

    1981-01-01

    Recent work in our laboratory has introduced a new class of electrostatic focus forming element for beams, the ELCO lens. It compares favourably with the electrostatic and magnetic quadrupole elements conventionally used for microbeam formation. The ELCO lens does however have disadvantages associated with apertures and alignment. We have continued with the development of ion beam lenses and have evolved a further class of lens element which eliminates aperture and alignment problems. This new element can be combined like optical lenses into an aberration corrected system. Experimental measurement on the basic lens element has confirmed mathematical analysis of ion trajectories through the element. This mathematical analysis predicts that the basic element can be combined into a corrected lens system for, either: (1) high resolution microprobe formation with intrinsic rastering ability, the spot size limited only by the beam properties; or (2) high quality image formation with large magnification/demagnification ratio and wide angular aperture. (orig.)

  3. Growth and optical development of the ocular lens of the squid (Sepioteuthis lessoniana).

    Science.gov (United States)

    Sivak, J G; West, J A; Campbell, M C

    1994-09-01

    Lens focal properties (spherical aberration), diameter and relative anterior/posterior proportions were measured photographically for Japanese squid (Sepioteuthis lessoniana) at ages 4-6 weeks, 7-9 weeks and 7-8 months. The measures involved photographing the refractive effects of lenses in a physiological solution, with and without an index matching fluid (polyvinylpyrroloidone solution), on a parallel array of fine helium-neon laser beams. Spherical aberration was determined from measurement of back vertex distance. Similar measurements were made on lenses from the eyes of cuttlefish (Sepia officinalis). The cephalopod lens develops as hemispheric halves from separate ectodermal sources. The posterior component contributes, on average, about 60% of axial lens diameter in S. lessoniana of all ages and 55% in S. officinalis. However, these proportions vary widely in both species. All lenses of both species show that spherical aberration is neutralized, although small variations in back vertex distance (positive and negative spherical aberration) were measured. Preliminary measures indicate that the refractive index distribution within the cephalopod lens varies in a manner reminiscent of teleost lenses. Squid lenses from animals 7-9 weeks of age were optimally corrected for spherical aberration. Some squid of this age, from a separate tank, showed a high incidence of cataract development. In each case, lens opacification was caused by deterioration of the posterior lens component.

  4. Knowledge-based optical system design: some optical systems generated by the KBOSD

    Science.gov (United States)

    Nouri, Taoufik; Erard, Pierre-Jean

    1993-04-01

    This work is a new approach for the design of start optical systems and represents a new contribution of artificial intelligence techniques in the optical design field. A knowledge-based optical-systems design (KBOSD), based on artificial intelligence algorithms, first order logic, knowledge representation, rules, and heuristics on lens design, is realized. This KBOSD is equipped with optical knowledge in the domain of centered dioptrical optical systems used at low aperture and small field angles. This KBOSD generates centered dioptrical, on-axis and low-aperture optical-systems, which are used as start systems for the subsequent optimization by existing lens design programs. This KBOSD produces monochromatic or polychromatic optical systems, such as singlet lens, doublet lens, triplet lens, reversed singlet lens, reversed doublet lens, reversed triplet lens, and telescopes. In the design of optical systems, the KBOSD takes into account many user constraints such as cost, resistance of the optical material (glass) to chemical, thermal, and mechanical effects, as well as the optical quality such as minimal aberrations and chromatic aberrations corrections. This KBOSD is developed in the programming language Prolog and has knowledge on optical design principles and optical properties and uses neither a lens library nor a lens data base, it is completely based on optical design knowledge.

  5. Modulation transfer function estimation of optical lens system by adaptive neuro-fuzzy methodology

    Science.gov (United States)

    Petković, Dalibor; Shamshirband, Shahaboddin; Pavlović, Nenad T.; Anuar, Nor Badrul; Kiah, Miss Laiha Mat

    2014-07-01

    The quantitative assessment of image quality is an important consideration in any type of imaging system. The modulation transfer function (MTF) is a graphical description of the sharpness and contrast of an imaging system or of its individual components. The MTF is also known and spatial frequency response. The MTF curve has different meanings according to the corresponding frequency. The MTF of an optical system specifies the contrast transmitted by the system as a function of image size, and is determined by the inherent optical properties of the system. In this study, the adaptive neuro-fuzzy (ANFIS) estimator is designed and adapted to estimate MTF value of the actual optical system. Neural network in ANFIS adjusts parameters of membership function in the fuzzy logic of the fuzzy inference system. The back propagation learning algorithm is used for training this network. This intelligent estimator is implemented using Matlab/Simulink and the performances are investigated. The simulation results presented in this paper show the effectiveness of the developed method.

  6. Enhanced depth-of-field of an integral imaging microscope using a bifocal holographic optical element-micro lens array.

    Science.gov (United States)

    Kwon, Ki-Chul; Lim, Young-Tae; Shin, Chang-Won; Erdenebat, Munkh-Uchral; Hwang, Jae-Moon; Kim, Nam

    2017-08-15

    We propose and implement an integral imaging microscope with extended depth-of-field (DoF) using a bifocal holographic micro lens array (MLA). The properties of the two MLAs are switched via peristrophic multiplexing, where different properties of the MLA are recorded onto the single holographic optical element (HOE). The recorded MLA properties are perpendicular to each other: after the first mode is recorded, the HOE is rotated by 90° clockwise, and the second mode is recorded. The experimental results confirm that the DoF of the integral imaging microscopy system is extended successfully by using the bifocal MLA.

  7. High-resolution spectral domain optical coherence tomography technology for the visualization of contact lens to cornea relationships.

    Science.gov (United States)

    Gonzalez-Meijome, Jose M; Cerviño, Alejandro; Carracedo, Gonzalo; Queiros, Antonio; Garcia-Lázaro, Santiago; Ferrer-Blasco, Teresa

    2010-12-01

    To study the utility of high-resolution spectral domain optical coherence tomography (HR SOCT) in imaging the contact lens (CL) to cornea relationships with advanced CL designs for ecstatic corneas and corneal refractive therapy. Copernicus HR SOCT (Optopol Technology SA, Zawiercie, Poland) was used to evaluate different lens materials and designs in situ and for the preliminary assessment of the materials and corneal response to hypoxic situations. SOCT is capable of highlighting very subtle and interesting features of the CL-cornea relationships in a wide range of applications such as in rigid gas-permeable corneal and semiscleral lenses, in corneal refractive therapy and application of CLs in ocular pathology, and in the evaluation of the physiological response of the cornea. HR SOCT is a powerful tool capable of providing sharp images of the anterior ocular surface highlighting the relationship between lens and cornea with great detail. This methodology has several applications to enhance fitting modeling with modern designs for advanced CL treatments.

  8. Application of optical lens of a CD writer for detecting the blood glucose semi-invasively

    Energy Technology Data Exchange (ETDEWEB)

    Meshram, N. D., E-mail: meshramnileshsd@gmail.com [Mathuradas Mohota College of Sciences, Nagpur-440009 (India); Dahikar, P. B., E-mail: pbdahikar@rediffmail.com [Kamla Nehru Mahavidyalaya, Sakkardara Square, Nagpur-440009 (India)

    2014-10-15

    Recent technological advancements in the photonics industry have led to a resurgence of interest in optical glucose sensing and to realistic progress toward the development of an optical glucose sensor. Such a sensor has the potential to significantly improve the quality of life for the estimated 16 million diabetics in this country by making routine glucose measurements more convenient. Currently over 100 small companies and universities are working to develop noninvasive or minimally invasive glucose sensing technologies, and optical methods play a large role in these efforts. It has become overwhelmingly clear that frequent monitoring and tight control of blood sugar levels are requisite for effective management of Diabetes mellitus and reduction of the complications associated with this disease. The pain and trouble associated with current “finger-stick” methods for blood glucose monitoring result in decreased patient compliance and a failure to control blood sugar levels. Thus, the development of a convenient noninvasive blood glucose monitor holds the potential to significantly reduce the morbidity and mortality associated with Diabetes. A method and apparatus for noninvasive measurement of blood glucose concentration based on transilluminated laser beam via the Index Finger has been reported in this paper. This method depends on photodiode based laser operating at 632.8 nm wavelength. During measurement, the index finger is inserted into the glucose sensing unit, the transilluminated optical signal is converted into an electrical signal, compared with the reference electrical signal, and the obtained difference signal is processed by signal processing unit which presents the results in the form of blood glucose concentration. This method would enable the monitoring blood glucose level of the diabetic patient continuously, safely and noninvasively.

  9. Application of optical lens of a CD writer for detecting the blood glucose semi-invasively

    Science.gov (United States)

    Meshram, N. D.; Dahikar, P. B.

    2014-10-01

    Recent technological advancements in the photonics industry have led to a resurgence of interest in optical glucose sensing and to realistic progress toward the development of an optical glucose sensor. Such a sensor has the potential to significantly improve the quality of life for the estimated 16 million diabetics in this country by making routine glucose measurements more convenient. Currently over 100 small companies and universities are working to develop noninvasive or minimally invasive glucose sensing technologies, and optical methods play a large role in these efforts. It has become overwhelmingly clear that frequent monitoring and tight control of blood sugar levels are requisite for effective management of Diabetes mellitus and reduction of the complications associated with this disease. The pain and trouble associated with current "finger-stick" methods for blood glucose monitoring result in decreased patient compliance and a failure to control blood sugar levels. Thus, the development of a convenient noninvasive blood glucose monitor holds the potential to significantly reduce the morbidity and mortality associated with Diabetes. A method and apparatus for noninvasive measurement of blood glucose concentration based on transilluminated laser beam via the Index Finger has been reported in this paper. This method depends on photodiode based laser operating at 632.8 nm wavelength. During measurement, the index finger is inserted into the glucose sensing unit, the transilluminated optical signal is converted into an electrical signal, compared with the reference electrical signal, and the obtained difference signal is processed by signal processing unit which presents the results in the form of blood glucose concentration. This method would enable the monitoring blood glucose level of the diabetic patient continuously, safely and noninvasively..

  10. Application of optical lens of a CD writer for detecting the blood glucose semi-invasively

    International Nuclear Information System (INIS)

    Meshram, N. D.; Dahikar, P. B.

    2014-01-01

    Recent technological advancements in the photonics industry have led to a resurgence of interest in optical glucose sensing and to realistic progress toward the development of an optical glucose sensor. Such a sensor has the potential to significantly improve the quality of life for the estimated 16 million diabetics in this country by making routine glucose measurements more convenient. Currently over 100 small companies and universities are working to develop noninvasive or minimally invasive glucose sensing technologies, and optical methods play a large role in these efforts. It has become overwhelmingly clear that frequent monitoring and tight control of blood sugar levels are requisite for effective management of Diabetes mellitus and reduction of the complications associated with this disease. The pain and trouble associated with current “finger-stick” methods for blood glucose monitoring result in decreased patient compliance and a failure to control blood sugar levels. Thus, the development of a convenient noninvasive blood glucose monitor holds the potential to significantly reduce the morbidity and mortality associated with Diabetes. A method and apparatus for noninvasive measurement of blood glucose concentration based on transilluminated laser beam via the Index Finger has been reported in this paper. This method depends on photodiode based laser operating at 632.8 nm wavelength. During measurement, the index finger is inserted into the glucose sensing unit, the transilluminated optical signal is converted into an electrical signal, compared with the reference electrical signal, and the obtained difference signal is processed by signal processing unit which presents the results in the form of blood glucose concentration. This method would enable the monitoring blood glucose level of the diabetic patient continuously, safely and noninvasively.

  11. OPTICAL REMOTE SENSING FOR AIR QUALITY MONITORING

    Science.gov (United States)

    The paper outlines recent developments in using optical remote sensing (ORS) instruments for air quality monitoring both for gaseous pollutants and airborne particulate matter (PM). The U.S. Environmental Protection Agency (EPA) has been using open-path Fourier transform infrared...

  12. Optics

    CERN Document Server

    Fincham, W H A

    2013-01-01

    Optics: Ninth Edition Optics: Ninth Edition covers the work necessary for the specialization in such subjects as ophthalmic optics, optical instruments and lens design. The text includes topics such as the propagation and behavior of light; reflection and refraction - their laws and how different media affect them; lenses - thick and thin, cylindrical and subcylindrical; photometry; dispersion and color; interference; and polarization. Also included are topics such as diffraction and holography; the limitation of beams in optical systems and its effects; and lens systems. The book is recommen

  13. Thermal lens study of thermo-optical properties and concentration quenching of Er3+-doped lead pyrophosphate based glasses

    Energy Technology Data Exchange (ETDEWEB)

    Santos, C. C. [Universidade Federal do Ceara, Ceara, Brazil; Rocha, U. [Grupo de Fotônica e Fluidos Complexos, Instituto de Física, Brazil; Guedes, Ilde [Universidade Federal do Ceara, Ceara, Brazil; Vermelho, M. V. D. [Instituto de Fisica, Universidade Federal de Alagoas, Brazil; Boatner, Lynn A [ORNL; Jacinto, C. [Instituto de Fisica, Universidade Federal de Alagoas, Brazil

    2012-01-01

    In this work, we have used the thermal lens technique combined with conventional spectroscopy to characterize the thermo-optical properties of Er3+-doped lead pyrophosphate-based glasses. More precisely, we have investigated and quantified experimentally the fluorescence quantum efficiencies of the Er3+ levels, and we describe the role of concentration quenching effects. The fluorescence quantum efficiency of the 4I13/2 level is very high when compared to other phosphate glasses, while that of the green-coupled levels is very small. Other important photonic materials parameters, such as the thermal diffusivity and temperature coefficient of the optical path length change, were obtained and compared with those of other glass systems. The cumulative results obtained here for the Er-doped lead pyrophosphate glass show that this material is a good candidate for photonic applications with a characteristic Er3+ infrared emission around 1550 nm.

  14. Visual and optical performance with two different diffractive multifocal intraocular lenses compared to a monofocal lens.

    Science.gov (United States)

    Alió, Jorge L; Piñero, David P; Plaza-Puche, Ana B; Amparo, Francisco; Jiménez, Ramón; Rodríguez-Prats, Jose L; Javaloy, Jaime

    2011-08-01

    To compare the visual acuity outcomes as well as the ocular optical performance of eyes implanted with either a monofocal or one of two diffractive multifocal intraocular lenses (IOLs). One hundred two consecutive eyes of 51 bilateral cataract patients (age 49 to 80 years) were divided into three groups: 22 eyes were implanted with a monofocal IOL (monofocal group), 40 eyes with the Acrysof ReSTOR SN6AD3 IOL (ReSTOR group), and 40 eyes with the Acri.Lisa 366D IOL (Acri.Lisa group). Visual acuity and contrast sensitivity were evaluated pre- and postoperatively. Additionally, ocular optical quality and intraocular aberrations were evaluated postoperatively. Significant improvement after surgery in uncorrected and corrected distance and near visual acuity was observed in all three groups (P≤.05). Uncorrected near visual acuity was significantly better in eyes from the ReSTOR and Acri.Lisa groups compared to the monofocal group (P≤.01). Photopic contrast sensitivity was significantly better for the spatial frequency of 3 cycles/degree in the monofocal group (P<.01). Significantly higher values of the ocular Strehl ratio and cutoff modulation transfer function spatial frequency were also found in the Acri.Lisa group (P=.01). An acceptable range of vision between near and distance peaks was observed in the defocus curves of the ReSTOR and Acri.Lisa groups. The AcrySof ReSTOR and Acri.Lisa 366D IOLs are able to successfully restore near and intermediate visual function after cataract surgery; however, the Acri.Lisa design seems to provide better optical performance. These results need to be confirmed in a randomized, prospective trial. Copyright 2011, SLACK Incorporated.

  15. CNN-coupled Humanoid Panoramic Annular Lens (PAL)-Optical System for Military Applications (Feasibility Study)

    National Research Council Canada - National Science Library

    Greguss, Pal

    2002-01-01

    ...) and the CNN chip for a few military applications. A polar beam splitter will be placed immediately after the relay lens to obtain two image planes, one will be used by the existing 64X64 CNN-UM focal plane array processor chip...

  16. All-optical microscope autofocus based on an electrically tunable lens and a totally internally reflected IR laser.

    Science.gov (United States)

    Bathe-Peters, M; Annibale, P; Lohse, M J

    2018-02-05

    Microscopic imaging at high spatial-temporal resolution over long time scales (minutes to hours) requires rapid and precise stabilization of the microscope focus. Conventional and commercial autofocus systems are largely based on piezoelectric stages or mechanical objective actuators. Objective to sample distance is either measured by image analysis approaches or by hardware modules measuring the intensity of reflected infrared light. We propose here a truly all-optical microscope autofocus taking advantage of an electrically tunable lens and a totally internally reflected infrared probe beam. We implement a feedback-loop based on the lateral position of a totally internally reflected infrared laser on a quadrant photodetector, as an indicator of the relative defocus. We show here how to treat the combined contributions due to mechanical defocus and deformation of the tunable lens. As a result, the sample can be kept in focus without any mechanical movement, at rates up to hundreds of Hertz. The device requires only reflective optics and can be implemented at a fraction of the cost required for a comparable piezo-based actuator.

  17. Optical Synchronization of a 10-G Ethernet Packet and Time-Division Multiplexing to a 50-Gb/s Signal Using an Optical Time Lens

    DEFF Research Database (Denmark)

    Hu, Hao; Laguardia Areal, Janaina; Palushani, Evarist

    2010-01-01

    A 10-G Ethernet packet with maximum packet size of 1518 bytes is synchronized to a master clock with 200-kHz frequency offset using a time lens. The input 10-Gb/s non-return-to-zero packet is at the same time converted into a return-to-zero (RZ) packet with a pulsewidth of 10 ps and then time......-division multiplexed with four 10-Gb/s optical time-division-multiplexing (OTDM) channels, thus constituting a 50-Gb/s OTDM serial signal. Error-free performances of the synchronized RZ packet and demultiplexed packet from the aggregated 50-Gb/s OTDM signal are achieved....

  18. Optics

    CERN Document Server

    Fincham, W H A

    2013-01-01

    Optics: Eighth Edition covers the work necessary for the specialization in such subjects as ophthalmic optics, optical instruments and lens design. The text includes topics such as the propagation and behavior of light; reflection and refraction - their laws and how different media affect them; lenses - thick and thin, cylindrical and subcylindrical; photometry; dispersion and color; interference; and polarization. Also included are topics such as diffraction and holography; the limitation of beams in optical systems and its effects; and lens systems. The book is recommended for engineering st

  19. In Situ Identification of Mineral Resources with an X-Ray-Optical "Hands-Lens" Instrument

    Science.gov (United States)

    Marshall, J.; Koppel, L.; Bratton, C.; Metzger, E.; Hecht, M.

    1999-01-01

    The recognition of material resources on a planetary surface requires exploration strategies not dissimilar to those employed by early field geologists who searched for ore deposits primarily from surface clues. In order to determine the location of mineral ores or other materials, it will be necessary to characterize host terranes at regional or subregional scales. This requires geographically broad surveys in which statistically significant numbers of samples are rapidly scanned from a roving platform. To enable broad-scale, yet power-conservative planetary-surface exploration, we are developing an instrument that combines x-ray diffractometry (XRD), x-ray fluorescence spectrometry (XRF), and optical capabilities; the instrument can be deployed at the end of a rover's robotic arm, without the need for sample capture or preparation. The instrument provides XRD data for identification of mineral species and lithological types; diffractometry of minerals is conducted by ascertaining the characteristic lattice parameters or "d-spacings" of mineral compounds. D-spacings of 1.4 to 25 angstroms can be determined to include the large molecular structures of hydrated minerals such as clays. The XRF data will identify elements ranging from carbon (Atomic Number = 6) to elements as heavy as barium (Atomic Number = 56). While a sample is being x-rayed, the instrument simultaneously acquires an optical image of the sample surface at magnifications from lx to at least 50x (200x being feasible, depending on the sample surface). We believe that imaging the sample is extremely important as corroborative sample-identification data (the need for this capability having been illustrated by the experience of the Pathfinder rover). Very few geologists would rely on instrument data for sample identification without having seen the sample. Visual inspection provides critical recognition data such as texture, crystallinity, granularity, porosity, vesicularity, color, lustre, opacity, and

  20. Beveled fiber-optic probe couples a ball lens for improving depth-resolved fluorescence measurements of layered tissue: Monte Carlo simulations

    International Nuclear Information System (INIS)

    Jaillon, Franck; Zheng Wei; Huang Zhiwei

    2008-01-01

    In this study, we evaluate the feasibility of designing a beveled fiber-optic probe coupled with a ball lens for improving depth-resolved fluorescence measurements of epithelial tissue using Monte Carlo (MC) simulations. The results show that by using the probe configuration with a beveled tip collection fiber and a flat tip excitation fiber associated with a ball lens, discrimination of fluorescence signals generated in different tissue depths is achievable. In comparison with a flat-tip collection fiber, the use of a large bevel angled collection fiber enables a better differentiation between the shallow and deep tissue layers by changing the excitation-collection fiber separations. This work suggests that the beveled fiber-optic probe coupled with a ball lens has the potential to facilitate depth-resolved fluorescence measurements of epithelial tissues

  1. Beveled fiber-optic probe couples a ball lens for improving depth-resolved fluorescence measurements of layered tissue: Monte Carlo simulations.

    Science.gov (United States)

    Jaillon, Franck; Zheng, Wei; Huang, Zhiwei

    2008-02-21

    In this study, we evaluate the feasibility of designing a beveled fiber-optic probe coupled with a ball lens for improving depth-resolved fluorescence measurements of epithelial tissue using Monte Carlo (MC) simulations. The results show that by using the probe configuration with a beveled tip collection fiber and a flat tip excitation fiber associated with a ball lens, discrimination of fluorescence signals generated in different tissue depths is achievable. In comparison with a flat-tip collection fiber, the use of a large bevel angled collection fiber enables a better differentiation between the shallow and deep tissue layers by changing the excitation-collection fiber separations. This work suggests that the beveled fiber-optic probe coupled with a ball lens has the potential to facilitate depth-resolved fluorescence measurements of epithelial tissues.

  2. Comparison of the quality of life for spectacle wearers and contact lens wearers before and after refractive surgery

    Directory of Open Access Journals (Sweden)

    Xi Chen

    2013-05-01

    Full Text Available AIM: To compare the difference of the quality of life(QOLof spectacle wearers or contact lens wearers before and after refractive surgery by the quality of life impact of refractive correction(QIRC. METHODS:Totally 72 cases were enrolled in the investigation with 50 spectacle wearers and 22 contact lens wearers. The QOL of them were surveyed by Chinese QIRC before surgery and 3 months later after surgery. RESULTS: 1. The QOL scores(42.29±4.90 in post-operation vs 39.30±5.16 in pre-operationand satisfaction scores(86.51±9.14 in post-operation vs 71.58±13.24 in pre-operationof spectacle wearers were higher after surgery more than before, and the difference was statistically significant(P<0.01. The vision and physical functioning(P<0.05, driving and activity in night(

  3. Division Multiplexing of 10 Gbit/s Ethernet Signals Synchronized by All-Optical Signal Processing Based on a Time-Lens

    DEFF Research Database (Denmark)

    Areal, Janaina Laguardia

    This Thesis presents 3 years work of an optical circuit that performs both pulse compression and frame synchronization and retiming. Our design aims at directly multiplexing several 10G Ethernet data packets (frames) to a high-speed OTDM link. This scheme is optically trans-parent and does...... pulse compression, as well. The over-all design is: (1) Pulses are converted from NRZ to RZ; (2) pulses are synchronized, retimed and further compressed at the specially de-signed time-lens; and (3) with adequate optical delays, frames from different input interfaces are added, with a simple optical...

  4. Nonlinear optical rectification in a vertically coupled lens-shaped InAs/GaAs quantum dots with wetting layers under hydrostatic pressure and temperature

    Energy Technology Data Exchange (ETDEWEB)

    Ben Mahrsia, R.; Choubani, M., E-mail: mohsenchoubani3@yahoo.fr; Bouzaiene, L.; Maaref, H.

    2016-06-25

    In this paper we explore the structure parameters, hydrostatic pressure and temperature effects on Nonlinear optical rectification (NOR) in an asymmetric vertically coupled lens-shaped InAs/GaAs quantum dots. During epitaxial growth, lens-shaped quantum dots (QDs) are formed on the wetting layer (WL). Many theoretical works have neglected WL and its effect on nonlinear optical properties of QD-based systems for sake of simplicity. However, in this work the WL has been shown to be so influential in the intersubband energy and nonlinear optical rectification magnitude. Also, a detailed and comprehensive study of the nonlinear optical rectification is theoretical investigated within the framework of the compact density-matrix approach and finite difference method (FDM). It's found that nonlinear optical rectification coefficient is strongly affected not only by the WL, but also by the pressure, temperature and the coupled width between the QDs. Obtained results revealed that a red or a blue shift cane be observed. This behavior in the NOR gives a new degree of freedom in regions of interest for device applications. - Highlights: • Vertically coupled lens-shaped InAs/GaAs quantum dots is investigated. • Photon energy shifts towards the red with increasing pressure. • Photon energy shifts towards the blue with increasing temperature. • Intersubband energy decreases with increasing the wetting layer width. • Nonlinear optical rectification magnitude is controlled and adjusted.

  5. A study on the realization of high resolution solid immersion lens-based near-field imaging optics by use of an annular aperture.

    Science.gov (United States)

    Moon, Hyungbae; Yoon, Yong-Joong; Kim, Wan-Chin; Park, No-Cheol; Park, Kyoung-Su; Park, Young-Pil

    2010-08-02

    We report on the realization of solid immersion lens (SIL)-based near-field (NF) optics with an annular aperture, which is targeted to achieve high optical resolution. A numerical aperture (NA) = 1.84 hemisphere SIL-optics with an annular aperture achieves higher optical resolution than the conventional NA = 2.0 SIL-optics. The designed aperture is fabricated by photo-lithography and dry-etching technique. Experimental verification of the designed optics was performed through beam spot profile measurement under NF imaging conditions. A 15% smaller full-width-at-half-maximum spot diameter is obtained by the aperture. We verified that this method gives an improvement of the resolution in the optical imaging systems requiring higher resolution.

  6. Optical waves in a gradient negative-index lens of a half-infinite length.

    Science.gov (United States)

    Ding, Yi S; Chan, C T; Wang, R P

    2013-10-16

    Materials with negative permittivity and permeability can overcome the diffraction limit, thereby making the sub-wavelength imaging possible. In this study, we analyze the effects of gradient index on a half-infinite perfect lens. We assume that the sharp interface between the vacuum and the negative-index material is replaced by a smooth transition profile such that the index gradually changing from positive to negative. Interestingly, we find that if the graded index profile is modeled by a tanh function, we can have closed-form analytical solutions for this problem, which is a distinct advantage as numerical solutions are not accurate for evanescent waves with large transverse wave vectors. By analyzing the analytical formulas we confirm that a nonzero total absorption can occur even for a near-zero absorption coefficient in the steady-state limit and the image plane contains multiple sub-wavelength images of an object.

  7. Comparison of Delay-Interferometer and Time- Lens-Based All-Optical OFDM Demultiplexers

    DEFF Research Database (Denmark)

    Lillieholm, Mads; Mulvad, Hans Christian Hansen; Galili, Michael

    2015-01-01

    In this letter, we present the first detailed numerical comparison of two promising all-optical schemes to demultiplex orthogonal frequency-division multiplexing (OFDM) signals. The investigated schemes are the optical discrete Fourier transformation (O-DFT) and the optical spectral magnification...... bandpass filters, is investigated. In the latter scheme, the OFDM spectrum is magnified, allowing for simple optical bandpass filtering of the individual subcarriers with reduced ICI. Ideally, only a single unit consisting of two time lenses is needed, reducing the complexity and potentially the energy...... consumption compared with the type of O-DFT scheme relying on many active gates. The bit-error-rate is estimated down to ~10-6 by Monte Carlo bit-error counting for a 32-subcarrier OFDM input signal, showing that a performance close to the ideal O-DFT is achievable for both the reduced-complexity O...

  8. Comparison of delay-interferometer and time-lens-based all-optical OFDM demultiplexers

    DEFF Research Database (Denmark)

    Lillieholm, Mads; Mulvad, Hans Christian Hansen; Galili, Michael

    2015-01-01

    In this paper we present the first detailed numerical comparison of two promising all-optical schemes to demultiplex orthogonal frequency-division multiplexing (OFDM) signals. The investigated schemes are the optical discrete Fourier transformation (O-DFT) and the optical spectral magnification (SM...... filters, is investigated. In the latter scheme the OFDM spectrum is magnified, allowing for simple optical bandpass filtering of the individual subcarriers with reduced ICI. Ideally only a single unit consisting of two time lenses is needed, reducing the complexity and potentially the energy consumption...... compared to the type of O-DFT scheme relying on many active gates. The bit-error-rate is estimated down to ∼10−6 by Monte Carlo bit-error counting for a 32-subcarrier OFDM input signal, showing that a performance close to the ideal O-DFT is achievable for both the reduced-complexity O-DFT and the SM scheme....

  9. Sapphire ball lens-based fiber probe for common-path optical coherence tomography and its applications in corneal and retinal imaging.

    Science.gov (United States)

    Zhao, Mingtao; Huang, Yong; Kang, Jin U

    2012-12-01

    We describe a common-path swept source optical coherence tomography fiber probe design using a sapphire ball lens for cross-sectional imaging and sensing for retina vitrectomy surgery. The high refractive index (n=1.75) of the sapphire ball lens improves the focusing power and enables the probe to operate in the intraocular space. The highly precise spherical shape of the sapphire lens also reduces astigmatism and coma compared to fused nonspherical ball lenses. A theoretical sensitivity model for common-path optical coherence tomography (CP-OCT) was developed to assess its optimal performance based on an unbalanced photodetector configuration. Two probe designs-with working distances 415 and 1221 μm and lateral resolution 11 and 18 μm-were implemented with sensitivity up to 88 dB, which is significantly higher than previously reported CP-OCT probes. We assessed the performances of the fiber probes by cross-sectional imaging a bovine cornea and retina in air and in vitreous gel with a 1310 nm swept source OCT system. To the best of our knowledge, this is the first demonstration of sapphire ball lens-based CP-OCT probes directly inserted into the vitreous gel of a bovine eyeball for ocular imaging with a sensitivity approaching the theoretical limitation of CP-OCT.

  10. Optical tweezers and surface plasmon resonance combination system based on the high numerical aperture lens

    Science.gov (United States)

    Shan, Xuchen; Zhang, Bei; Lan, Guoqiang; Wang, Yiqiao; Liu, Shugang

    2015-11-01

    Biology and medicine sample measurement takes an important role in the microscopic optical technology. Optical tweezer has the advantage of accurate capture and non-pollution of the sample. The SPR(surface plasmon resonance) sensor has so many advantages include high sensitivity, fast measurement, less consumption of sample and label-free detection of biological sample that the SPR sensing technique has been used for surface topography, analysis of biochemical and immune, drug screening and environmental monitoring. If they combine, they will play an important role in the biological, chemical and other subjects. The system we propose use the multi-axis cage system, by using the methods of reflection and transmiss ion to improve the space utilization. The SPR system and optical tweezer were builtup and combined in one system. The cage of multi-axis system gives full play to its accuracy, simplicity and flexibility. The size of the system is 20 * 15 * 40 cm3 and thus the sample can be replaced to switch between the optical tweezers system and the SPR system in the small space. It means that we get the refractive index of the sample and control the particle in the same system. In order to control the revolving stage, get the picture and achieve the data stored automatically, we write a LabVIEW procedure. Then according to the data from the back focal plane calculate the refractive index of the sample. By changing the slide we can trap the particle as optical tweezer, which makes us measurement and trap the sample at the same time.

  11. A liquid lens switching-based motionless variable fiber-optic delay line

    Science.gov (United States)

    Khwaja, Tariq Shamim; Reza, Syed Azer; Sheikh, Mumtaz

    2018-05-01

    We present a Variable Fiber-Optic Delay Line (VFODL) module capable of imparting long variable delays by switching an input optical/RF signal between Single Mode Fiber (SMF) patch cords of different lengths through a pair of Electronically Controlled Tunable Lenses (ECTLs) resulting in a polarization-independent operation. Depending on intended application, the lengths of the SMFs can be chosen accordingly to achieve the desired VFODL operation dynamic range. If so desired, the state of the input signal polarization can be preserved with the use of commercially available polarization-independent ECTLs along with polarization-maintaining SMFs (PM-SMFs), resulting in an output polarization that is identical to the input. An ECTL-based design also improves power consumption and repeatability. The delay switching mechanism is electronically-controlled, involves no bulk moving parts, and can be fully-automated. The VFODL module is compact due to the use of small optical components and SMFs that can be packaged compactly.

  12. Variations in retinal nerve fiber layer measurements on optical coherence tomography after implantation of trifocal intraocular lens.

    Science.gov (United States)

    García-Bella, Javier; Martínez de la Casa, José M; Talavero González, Paula; Fernández-Vigo, José I; Valcarce Rial, Laura; García-Feijóo, Julián

    2018-01-01

    To establish the changes produced after implantation of a trifocal intraocular lens (IOL) on retinal nerve fiber layer measurements performed with Fourier-domain optical coherence tomography (OCT). This prospective study included 100 eyes of 50 patients with bilateral cataract in surgical range, no other associated ocular involvement, refractive errors between +5 and -5 spherical diopters, and less than 1.5 D of corneal astigmatism. The eyes were operated by phacoemulsification with implantation of 2 different trifocal IOLs (FineVision and AT LISA tri 839MP) in randomized equal groups. Cirrus OCT and Spectralis OCT were performed before surgery and 3 months later. Both analyzed the thickness of the nerve fiber layer and thickness divided by quadrants (6 in case of Spectralis and 4 in case of Cirrus HD). The mean age of patients was 67.5 ± 5.8 years. The global nerve fiber layer thickness measured with Spectralis OCT was 96.77 μm before surgery and 99.55 μm after. With Cirrus OCT, the global thickness was 85.29 μm before surgery and 89.77 μm after. Statistically significant differences in global thickness measurements between preimplantation and postimplantation of the IOL were found with both OCT in the 2 groups. Statistically significant differences were also found in temporal and superior quadrants. The implantation of a diffractive trifocal IOL alters the results of the optic nerve fiber layer on Fourier-domain OCT in these patients, which should be taken into account in the posterior study of these patients.

  13. Quality of service in optical packet switched networks

    CERN Document Server

    Rahbar, Akbar G

    2015-01-01

    This book is a comprehensive study on OPS networks, its architectures, and developed techniques for improving its quality of switching and managing quality of service.  The book includes: Introduction to OPS networks, OOFDM networks, GMPLS-enabled optical networks, QoS in OPS networks Hybrid contention avoidance/resolution schemes in both long-haul and metro optical networks Hybrid optical switching schemes

  14. Optomechanical integrated simulation of Mars medium resolution lens with large field of view

    Science.gov (United States)

    Yang, Wenqiang; Xu, Guangzhou; Yang, Jianfeng; Sun, Yi

    2017-10-01

    The lens of Mars detector is exposed to solar radiation and space temperature for long periods of time during orbit, so that the ambient temperature of the optical system is in a dynamic state. The optical and mechanical change caused by heat will lead to camera's visual axis drift and the wavefront distortion. The surface distortion of the optical lens includes the displacement of the rigid body and the distortion of the surface shape. This paper used the calculation method based on the integrated optomechanical analysis, to explore the impact of thermodynamic load on image quality. Through the analysis software, established a simulation model of the lens structure. The shape distribution and the surface characterization parameters of the lens in some temperature ranges were analyzed and compared. the PV / RMS value, deformation cloud of the lens surface and quality evaluation of imaging was achieved. This simulation has been successfully measured the lens surface shape and shape distribution under the load which is difficult to measure on the experimental conditions. The integrated simulation method of the optical machine can obtain the change of the optical parameters brought by the temperature load. It shows that the application of Integrated analysis has play an important role in guiding the designing the lens.

  15. Field calculations, single-particle tracking, and beam dynamics with space charge in the electron lens for the Fermilab Integrable Optics Test Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Noll, Daniel [Goethe Univ., Frankfurt (Germany); Stancari, Giulio [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2015-11-17

    An electron lens is planned for the Fermilab Integrable Optics Test Accelerator as a nonlinear element for integrable dynamics, as an electron cooler, and as an electron trap to study space-charge compensation in rings. We present the main design principles and constraints for nonlinear integrable optics. A magnetic configuration of the solenoids and of the toroidal section is laid out. Singleparticle tracking is used to optimize the electron path. Electron beam dynamics at high intensity is calculated with a particle-in-cell code to estimate current limits, profile distortions, and the effects on the circulating beam. In the conclusions, we summarize the main findings and list directions for further work.

  16. Scheimpflug camera combined with placido-disk corneal topography and optical biometry for intraocular lens power calculation.

    Science.gov (United States)

    Kirgiz, Ahmet; Atalay, Kurşat; Kaldirim, Havva; Cabuk, Kubra Serefoglu; Akdemir, Mehmet Orcun; Taskapili, Muhittin

    2017-08-01

    The purpose of this study was to compare the keratometry (K) values obtained by the Scheimpflug camera combined with placido-disk corneal topography (Sirius) and optical biometry (Lenstar) for intraocular lens (IOL) power calculation before the cataract surgery, and to evaluate the accuracy of postoperative refraction. 50 eyes of 40 patients were scheduled to have phacoemulsification with the implantation of a posterior chamber intraocular lens. The IOL power was calculated using the SRK/T formula with Lenstar K and K readings from Sirius. Simulated K (SimK), K at 3-, 5-, and 7-mm zones from Sirius were compared with Lenstar K readings. The accuracy of these parameters was determined by calculating the mean absolute error (MAE). The mean Lenstar K value was 44.05 diopters (D) ±1.93 (SD) and SimK, K at 3-, 5-, and 7-mm zones were 43.85 ± 1.91, 43.88 ± 1.9, 43.84 ± 1.9, 43.66 ± 1.85 D, respectively. There was no statistically significant difference between the K readings (P = 0.901). When Lenstar was used for the corneal power measurements, MAE was 0.42 ± 0.33 D, but when simK of Sirius was used, it was 0.37 ± 0.32 D (the lowest MAE (0.36 ± 0.32 D) was achieved as a result of 5 mm K measurement), but it was not statistically significant (P = 0.892). Of all the K readings of Sirius and Lenstar, Sirius 5-mm zone K readings were the best in predicting a more precise IOL power. The corneal power measurements with the Scheimpflug camera combined with placido-disk corneal topography can be safely used for IOL power calculation.

  17. Effect of pupillary dilation on Haigis formula-calculated intraocular lens power measurement by using optical biometry

    Directory of Open Access Journals (Sweden)

    Khambhiphant B

    2016-07-01

    formula, intraocular lens, IOLMaster, optical biometry, pupillary dilation

  18. Wide Field-of-View Fluorescence Imaging with Optical-Quality Curved Microfluidic Chamber for Absolute Cell Counting

    Directory of Open Access Journals (Sweden)

    Mohiuddin Khan Shourav

    2016-07-01

    Full Text Available Field curvature and other aberrations are encountered inevitably when designing a compact fluorescence imaging system with a simple lens. Although multiple lens elements can be used to correct most such aberrations, doing so increases system cost and complexity. Herein, we propose a wide field-of-view (FOV fluorescence imaging method with an unconventional optical-quality curved sample chamber that corrects the field curvature caused by a simple lens. Our optics simulations and proof-of-concept experiments demonstrate that a curved substrate with lens-dependent curvature can reduce greatly the distortion in an image taken with a conventional planar detector. Following the validation study, we designed a curved sample chamber that can contain a known amount of sample volume and fabricated it at reasonable cost using plastic injection molding. At a magnification factor of approximately 0.6, the curved chamber provides a clear view of approximately 119 mm2, which is approximately two times larger than the aberration-free area of a planar chamber. Remarkably, a fluorescence image of microbeads in the curved chamber exhibits almost uniform intensity over the entire field even with a simple lens imaging system, whereas the distorted boundary region has much lower brightness than the central area in the planar chamber. The absolute count of white blood cells stained with a fluorescence dye was in good agreement with that obtained by a commercially available conventional microscopy system. Hence, a wide FOV imaging system with the proposed curved sample chamber would enable us to acquire an undistorted image of a large sample volume without requiring a time-consuming scanning process in point-of-care diagnostic applications.

  19. Low-dose CT of the paranasal sinuses with eye lens protection: effect on image quality and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Hein, Eike; Rogalla, Patrik; Klingebiel, Randolph; Hamm, Bernd [Department of Diagnostic and Interventional Radiology, Charite Hospital, Humboldt-Universitaet zu Berlin (Germany)

    2002-07-01

    The purpose of the study was to assess the effect of lens protection on image quality and radiation dose to the eye lenses in CT of the paranasal sinuses. In 127 patients referred to rule out sinusitis, an axial spiral CT with a lens protection placed on the patients eyes was obtained (1.5/2/1, 50 mAs, 120 kV). Coronal views were reconstructed at 5-mm interval. To quantify a subjective impression of image quality, three regions of interest within the eyeball were plotted along a line perpendicular to the protection at 2, 5, and 9 mm beneath skin level on the axial images. Additionally, dose reduction of a bismuth-containing latex shield was measured using a film-dosimetry technique. The average eyeball density was 17.97 HU (SD 3.7 HU). The relative increase in CT density was 180.6 (17.7), 103.3 (11.7), and 53.6 HU (9.2), respectively. There was no diagnostic information loss on axial and coronal views observed. Artifacts were practically invisible on images viewed in a bone window/level setting. The use of the shield reduced skin radiation from 7.5 to 4.5 mGy. The utilization of a radioprotection to the eye lenses in paranasal CT is a suitable and effective means of reducing skin radiation by 40%. (orig.)

  20. Zero-index photonic crystal as low-aberration optical lens (Conference Presentation)

    Science.gov (United States)

    Dong, Jian-Wen; He, Xin-Tao; Deng, Wei-Min; Yuan, Jia-Jun

    2016-09-01

    Fermionic Dirac cones have attracted tremendous attention in the electronic systems, such as topological insulator and graphene. As the classical analogs, photonic Dirac dispersions at the center of momentum space reveal a unique feature other than fermionic systems, i.e. zero-refractive-index behavior. In principle, such all-dielectric metamaterial is easily capable of scaling into optical wavelength, but it is seldom to address and promote to functional device with large area in silicon nanophotonics. Here, we show a prototype of large-area concave metalens consisting of silicon nanopillars array on silicon platform. The device was etched from n-type (100) single crystalline Si substrate by a top-down method. In theoretical prediction, such metalens can be modeled as a two-dimensional photonic crystal with conical bands at near-infrared wavelength. In this way, light focusing effect in the large-area metalens was observed directly through the out-of-plane scattering from the irregular substrate. The focal spot, which was very close to the curvature center of the metalens surface, indicated a little phase change of near-zero refractive index silicon photonic crystal. The effective refractive index retrieved from optical microscope images was quantitatively consistent with those from effective medium theory. The device performs as a near-aberration-free metalens near Dirac wavelength due to zero refractive index. Furthermore, it reveals a potential application for spectral detection based on wavelength-dependent effective index. The proposed strategy provides a feasible way for silicon-based application of zero-refractive-index photonic crystals.

  1. Athermal design and analysis of glass-plastic hybrid lens

    Science.gov (United States)

    Yang, Jian; Cen, Zhaofeng; Li, Xiaotong

    2018-01-01

    With the rapid development of security market, the glass-plastic hybrid lens has gradually become a choice for the special requirements like high imaging quality in a wide temperature range and low cost. The reduction of spherical aberration is achieved by using aspherical surface instead of increasing the number of lenses. Obviously, plastic aspherical lens plays a great role in the cost reduction. However, the hybrid lens has a priority issue, which is the large thermal coefficient of expansion of plastic, causing focus shift and seriously affecting the imaging quality, so the hybrid lens is highly sensitive to the change of temperature. To ensure the system operates normally in a wide temperature range, it is necessary to eliminate the influence of temperature on the hybrid lens system. A practical design method named the Athermal Material Map is summarized and verified by an athermal design example according to the design index. It includes the distribution of optical power and selection of glass or plastic. The design result shows that the optical system has excellent imaging quality at a wide temperature range from -20 ° to 70 °. The method of athermal design in this paper has generality which could apply to optical system with plastic aspherical surface.

  2. Gravitational lens optical scalars in terms of energy-momentum distributions in the cosmological framework

    Science.gov (United States)

    Boero, Ezequiel F.; Moreschi, Osvaldo M.

    2018-04-01

    We present new results on gravitational lensing over cosmological Robertson-Walker backgrounds which extend and generalize previous works. Our expressions show the presence of new terms and factors which have been neglected in the literature on the subject. The new equations derived here for the optical scalars allow to deal with more general matter content including sources with non-Newtonian components of the energy-momentum tensor and arbitrary motion. Our treatment is within the framework of weak gravitational lenses in which first-order effects of the curvature are considered. We have been able to make all calculations without referring to the concept of deviation angle. This in turn, makes the presentation shorter but also allows for the consideration of global effects on the Robertson-Walker background that have been neglected in the literature. We also discuss two intensity magnifications that we define in this article; one coming from a natural geometrical construction in terms of the affine distance, that we here call \\tilde{μ }, and the other adapted to cosmological discussions in terms of the redshift, that we call μ΄. We show that the natural intensity magnification \\tilde{μ } coincides with the standard angular magnification (μ).

  3. Adaptive neuro-fuzzy estimation of optimal lens system parameters

    Science.gov (United States)

    Petković, Dalibor; Pavlović, Nenad T.; Shamshirband, Shahaboddin; Mat Kiah, Miss Laiha; Badrul Anuar, Nor; Idna Idris, Mohd Yamani

    2014-04-01

    Due to the popularization of digital technology, the demand for high-quality digital products has become critical. The quantitative assessment of image quality is an important consideration in any type of imaging system. Therefore, developing a design that combines the requirements of good image quality is desirable. Lens system design represents a crucial factor for good image quality. Optimization procedure is the main part of the lens system design methodology. Lens system optimization is a complex non-linear optimization task, often with intricate physical constraints, for which there is no analytical solutions. Therefore lens system design provides ideal problems for intelligent optimization algorithms. There are many tools which can be used to measure optical performance. One very useful tool is the spot diagram. The spot diagram gives an indication of the image of a point object. In this paper, one optimization criterion for lens system, the spot size radius, is considered. This paper presents new lens optimization methods based on adaptive neuro-fuzzy inference strategy (ANFIS). This intelligent estimator is implemented using Matlab/Simulink and the performances are investigated.

  4. Ultra-high resolution optical coherence tomography for encapsulation quality inspection

    KAUST Repository

    Czajkowski, Jakub

    2011-08-28

    We present the application of ultra-high resolution optical coherence tomography (UHR-OCT) in evaluation of thin, protective films used in printed electronics. Two types of sample were investigated: microscopy glass and organic field effect transistor (OFET) structure. Samples were coated with thin (1-3 μm) layer of parylene C polymer. Measurements were done using experimental UHR-OCT device based on a Kerr-lens mode locked Ti: sapphire femtosecond laser, photonic crystal fibre and modified, free-space Michelson interferometer. Submicron resolution offered by the UHR-OCT system applied in the study enables registration of both interfaces of the thin encapsulation layer. Complete, volumetric characterisation of protective layers is presented, demonstrating possibility to use OCT for encapsulation quality inspection. © Springer-Verlag 2011.

  5. Light Microscopy Research Group (LMRG): International Test Results for Objective Lens Quality, Resolution, Spectral Accuracy and Spectral Separation for Confocal Laser Scanning Microscopes (CLSM)

    Science.gov (United States)

    Thibault, Marc; Bayles, Carol J.; Eason, Brady; Girard, Anne-Marie; Jinadasa, Tushare; Opansky, Cynthia; Schulz, Katherine; Brown, Claire M.; Cole, Richard W.

    2013-01-01

    As part of an ongoing effort to increase image reproducibility and fidelity in addition to improving cross-instrument consistency we have developed four separate instrument quality tests to augment the ones previously reported. 1) Objective lens quality 2) Resolution 3) Spectral accuracy of the wavelength information from spectral detectors 4) Spectral Separation tested the accuracy and quality of un-mixing algorithms. To ascertain the usefulness of these tests as well as to determine the current ““state”” of microscopes in use, test specimens and detailed protocols were made available worldwide free-of-charge. 55 laboratories located in 18 countries provided data. Objective lens quality: good with most issues arising from user errors or stage/focus drift, approximately 10% of lenses had aberrations. Resolution: within an average of approximately 25% of theoretical values. Spectral accuracy: excellent, even for low resolution systems. Spectral un-mixing: good, poor data collection was the main cause of low quality data.

  6. Double lens device for tunable harmonic generation of laser beams in KBBF/RBBF crystals or other non-linear optic materials

    Science.gov (United States)

    Kaminski, Adam

    2017-08-22

    A method and apparatus to generate harmonically related laser wavelengths includes a pair of lenses at opposing faces of a non-linear optical material. The lenses are configured to promote incoming and outgoing beams to be normal to each outer lens surface over a range of acceptance angles of the incoming laser beam. This reduces reflection loss for higher efficiency operation. Additionally, the lenses allow a wider range of wavelengths for lasers for more universal application. Examples of the lenses include plano-cylindrical and plano-spherical form factors.

  7. The role of low light intensity: A step towards understanding the connection between light, optic/lens and photovoltaic behavior for Sb2S3 thin-film solar cells

    Science.gov (United States)

    Lojpur, Vesna; Mitrić, Miodrag; Validžić, Ivana Lj

    2018-05-01

    We report here an optic/lens system that we used so far, for cooling the surface of solar cells, the reduction of light intensity and the change of light distribution that reaches the surface of the solar cell. The objective was to improve photovoltaic characteristics under very low light illumination, as well as to understand the connection between light, optic/lens and photovoltaic behavior for Sb2S3 thin-film solar cells. It was found that for all so far designed thin-film solar cells made and based on the synthesized Sb2S3, optics/lens system causes an increase in open circuit voltage (VOC) and short circuit current (ISC) and thus the efficiencies of made solar devices. Values of energy gaps for the thin-films made devices were in the range from 1.4 to 2 eV. Improvements of the photovoltaic response of the designed devices are found to be better at the lower light intensity (5% sun), than at higher intensities of light. For the same intensity of light used optic/lens improves the efficiency of the devices, by changing the light distribution. Other processes that are related to the optics/lens system, leading to an increase in ISC and VOC and consequently to an increase in efficiencies of the designed devices, are investigated.

  8. Contact lens surface by electron beam

    International Nuclear Information System (INIS)

    Shin, Jung Hyuck; Lee, Suk Ju; Hwang, Kwang Ha; Jeon Jin

    2011-01-01

    Contact lens materials needs good biocompatibility, high refractive index, high optical transparency, high water content etc. Surface treat method by using plasma and radiation can modify the physical and/or chemical properties of the contact lens surface. Radiation technology such as electron beam irradiation can apply to polymerization reaction and enhance the functionality of the polymer.The purpose of this study is to modify of contact lens surface by using Eb irradiation technology. Electron beam was irradiated to the contact lens surface which was synthesized thermal polymerization method and commercial contact lens to modify physical and chemical properties. Ft-IR, XP, UV-vis spectrophotometer, water content, oxygen trans-metastability were used to characterize the surface state, physicochemical, and optical property of the contact lens treated with Eb. The water content and oxygen transmissibility of the contact lens treated with Eb were increased due to increase in the hydrophilic group such as O-C=O and OH group on the contact lens surface which could be produced by possible reaction between carbon and oxygen during the Eb irradiation. All of the lenses showed the high optical transmittance above 90%. In this case of B/Es, TES, Ti contact lens, the optical transmittance decreased about 5% with increasing Eb dose in the wavelength of UV-B region. The contact lens modified by Eb irradiation could improve the physical properties of the contact lens such as water content and oxygen transmissibility

  9. Through a Different Lens: Bridging the Expectation-Perception (Quality) Divide in Higher Education

    Science.gov (United States)

    Yeo, Roland K.; Marquardt, Michael J.

    2011-01-01

    The paper draws on the underpinnings of SERVQUAL (a Service Quality measurement model) and explores three key aspects of service standards as adopted by an Engineering School in Singapore: customer orientation, course design/delivery and support services. Qualitative methodology was employed and data were collected by means of structured in-depth…

  10. Electro-optic control of photographic imaging quality through ‘Smart Glass’ windows in optics demonstrations

    Science.gov (United States)

    Ozolinsh, Maris; Paulins, Paulis

    2017-09-01

    An experimental setup allowing the modeling of conditions in optical devices and in the eye at various degrees of scattering such as cataract pathology in human eyes is presented. The scattering in cells of polymer-dispersed liquid crystals (PDLCs) and ‘Smart Glass’ windows is used in the modeling experiments. Both applications are used as optical obstacles placed in different positions of the optical information flow pathway either directly on the stimuli demonstration computer screen or mounted directly after the image-formation lens of a digital camera. The degree of scattering is changed continuously by applying an AC voltage of up to 30-80 V to the PDLC cell. The setup uses a camera with 14 bit depth and a 24 mm focal length lens. Light-emitting diodes and diode-pumped solid-state lasers emitting radiation of different wavelengths are used as portable small-divergence light sources in the experiments. Image formation, optical system point spread function, modulation transfer functions, and system resolution limits are determined for such sample optical systems in student optics and optometry experimental exercises.

  11. Electro-optic control of photographic imaging quality through ‘Smart Glass’ windows in optics demonstrations

    International Nuclear Information System (INIS)

    Ozolinsh, Maris; Paulins, Paulis

    2017-01-01

    An experimental setup allowing the modeling of conditions in optical devices and in the eye at various degrees of scattering such as cataract pathology in human eyes is presented. The scattering in cells of polymer-dispersed liquid crystals (PDLCs) and ‘Smart Glass’ windows is used in the modeling experiments. Both applications are used as optical obstacles placed in different positions of the optical information flow pathway either directly on the stimuli demonstration computer screen or mounted directly after the image-formation lens of a digital camera. The degree of scattering is changed continuously by applying an AC voltage of up to 30–80 V to the PDLC cell. The setup uses a camera with 14 bit depth and a 24 mm focal length lens. Light-emitting diodes and diode-pumped solid-state lasers emitting radiation of different wavelengths are used as portable small-divergence light sources in the experiments. Image formation, optical system point spread function, modulation transfer functions, and system resolution limits are determined for such sample optical systems in student optics and optometry experimental exercises. (paper)

  12. Quality of vision in patients implanted with aspherical and spherical intraocular lens: Intraindividual comparison

    Directory of Open Access Journals (Sweden)

    Francesco Semeraro

    2014-01-01

    Full Text Available Aims: To compare the quality of vision in pseudophakic patients implanted with aspherical and spherical intraocular lenses (IOLs. Materials and Methods: Randomized prospective longitudinal intrapatient comparison between aspherical and spherical IOLs performed on 22 patients who underwent bilateral cataract surgery. Best corrected visual acuity, subjective contrast sensitivity, Strehl ratio and spherical aberrations (SA, and higher order wavefront aberrations for a 3.5 mm and a 6.0 mm pupil were measured after 3 months of cataract surgery. Results: SA (Z4,0 decreased significantly in eyes with aspherical IOL implant (P = 0.004. Modulation transfer function (MTF and point spread function (PSF resulted no significant difference between the two groups (P = 0.87; P = 0.32. Conclusion: Although the SA is significantly lower in eyes implanted with aspherical IOL, the quality of vision determined with MTF and PSF does not significantly differ for subjective and objective parameters that were analyzed.

  13. Coordinating standards and applications for optical water quality sensor networks

    Science.gov (United States)

    Bergamaschi, B.; Pellerin, B.

    2011-01-01

    Joint USGS-CUAHSI Workshop: In Situ Optical Water Quality Sensor Networks; Shepherdstown, West Virginia, 8-10 June 2011; Advanced in situ optical water quality sensors and new techniques for data analysis hold enormous promise for advancing scientific understanding of aquatic systems through measurements of important biogeochemical parameters at the time scales over which they vary. High-frequency and real-time water quality data also provide the opportunity for early warning of water quality deterioration, trend detection, and science-based decision support. However, developing networks of optical sensors in freshwater systems that report reliable and comparable data across and between sites remains a challenge to the research and monitoring community. To address this, the U.S. Geological Survey (USGS) and the Consortium of Universities for the Advancement of Hydrologic Science, Inc. (CUAHSI), convened a 3-day workshop to explore ways to coordinate development of standards and applications for optical sensors, as well as handling, storage, and analysis of the continuous data they produce.

  14. Fabrication of a high-integration multi-spectral imaging lens and its application

    Science.gov (United States)

    Jin, Jian; Di, Si; Chen, Xianshuai

    2017-10-01

    In this paper, a high-integration multi-spectral imaging lens was developed by micro-fabrication technology. By using multiple photo-etching and thermal reflow process, a microlens array and a multi-channels filter were integrated together without position mismatch. Besides, light block layer and isolation layer were brought in the structure to improve the imaging quality. Its fabrication process is described in detail and the optical property was tested by imaging experiments. The multi-spectral imaging lens has 9 optical channels, each channel capable of filtering and imaging independently. The imaging results indicate that the lens can capture pictures of visible bands and near-infrared band at the same time. Because of its high level of integration and image parallel capture capability, the novel lens is suitable to be applied in extracting conceal information and biomedical imaging.

  15. Predicting visual performance from optical quality metrics in keratoconus.

    Science.gov (United States)

    Schoneveld, Paul; Pesudovs, Konrad; Coster, Douglas J

    2009-05-01

    The aim was to identify optical quality metrics predictive of visual performance in eyes with keratoconus and penetrating keratoplasty (PK) for keratoconus. Fifty-four participants were recruited for this prospective, cross-sectional study. Data were collected from one eye of each participant: 26 keratoconus, 10 PK and 18 normal eyes: average age (mean +/- standard deviation) 45.2 +/- 10.6 years and 56 per cent female. Visual performance was tested by 10 methods including visual acuity (VA), both high and low contrast (HC- and LC-) and high and low luminance (LL-), and Pelli-Robson contrast sensitivity, all tested with and without glare. Corneal first surface wavefront aberrations were calculated from Orbscan corneal topographic data using VOLPro software v7.08 (Sarver and Associates) as a tenth-order Zernike expansion across three, 4.0 mm and 5.0 mm pupils and converted into 31 optical quality metrics. Pearson correlation coefficients and linear regression were used to relate wavefront aberration metrics to visual performance. Visual performance was highly predictable from optical quality with the average correlation of the order of 0.5. Pupil fraction metrics (for example, PFWc) were responsible for all of the highest correlations at large pupils for example, with HCVA (r = 0.80), LCVA (r = 0.80) and LLLCVA (r = 0.75). Image plane metrics, derived from the optical transfer function (OTF) were responsible for most of the highest correlations at smaller pupils for example, volume under the OTF (VOTF) with HCVA (r = 0.76) and LCVA (r = 0.73). As in normal eyes, visual performance in keratoconus was predicable from optical quality; albeit by different metrics. Optical quality metrics predictive of visual performance in normal eyes, for example, visual Strehl, lack the dynamic range to represent visual performance in highly aberrated eyes with keratoconus. Optical quality outcomes for keratoconus could be reported using many different metrics, but pupil fraction

  16. Quality of life evaluation after implantation of 2 multifocal intraocular lens models and a monofocal model.

    Science.gov (United States)

    Alió, Jorge L; Plaza-Puche, Ana B; Piñero, David P; Amparo, Francisco; Rodríguez-Prats, Jose L; Ayala, María José

    2011-04-01

    To compare vision-related quality of life using the National Eye Institute Visual Function Questionnaire (NEI VFQ-25) in patients with 1 of 3 types of intraocular lenses (IOLs) and to correlate it with postoperative visual outcomes. Vissum Corporation-Instituto Oftalmológico de Alicante, Alicante, Spain. Comparative case series. This study comprised eyes having cataract surgery with bilateral implantation of a monofocal IOL (Group A), apodized multifocal IOL (Group B), or full diffractive multifocal IOL (Group C). Distance and near visual acuities, contrast sensitivity, and quality of life were evaluated preoperatively and postoperatively. The study enrolled 106 eyes (53 patients; age range 49 to 80 years). All groups had significant improvement in uncorrected and corrected distance visual acuities postoperatively (P ≤.05). Near vision outcomes were significantly better in Groups B and C (P ≤.01). Groups B and C had significantly less difficulty in some near tasks, such as reading the newspaper (A-B, P=.02; A-C, P=.02) or reading bills (A-B, P=.04; A-C, P=.004). Group C also had significantly less difficulty driving at night than Group B (P<.01). Near visual acuity and contrast sensitivity were significantly correlated with difficulty in near visual tasks in Groups B and C. Night-driving difficulty correlated significantly with contrast sensitivity in Group B. Patients with multifocal IOLs could perform several daily tasks at near and intermediate distances, with less night-driving limitation with the full diffractive IOL than with apodized multifocal and monofocal IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  17. The University of Santo Tomas Viewed from the Lens of Total Quality Management: Implications to Total Quality Education

    Science.gov (United States)

    de Guzman, Allan B.; Torres, Josefina R.

    2004-01-01

    Considered as a major management approach for improving organizational performance and competitive advantage, Total Quality Management (TQM) poses a challenge to dynamic institutions to adopt a systemic philosophy that places emphasis on customer needs and a commitment to a culture of excellence. Higher education institutions (HEIs) as learning…

  18. Quadrupole magnetic lens

    International Nuclear Information System (INIS)

    Piskunov, V.A.

    1981-01-01

    The following connection of windings of electromagnet is suggested for simplification of the design of qUadrupole magnetic lens intended for use in radiotechnical and electron-optical devices. The mentioned windings are connected with each other by a bridge scheme and the variable resistors are switched in its diagonals in the lens containing four electromagnet with windings connected with two variable resistors the mobile contacts of which are connected with a direct current source. Current redistribution between left windings and right windings takes place at shift of mobile contact of variable resistor, and current redistribution between upper and low coils of electromagnets takes place at shifting mobile contact of the other variable resistor. In this case smooth and independent electron-optical misalignment of lens by two mutually perpendicular directions proceeds. Use of the given design of the lens in the oscillograph permits to use printing assembly for alignment plate and to reduce the number of connections at the expense of decreasing the number of resistors

  19. Impact of the optical depth of field on cytogenetic image quality

    Science.gov (United States)

    Qiu, Yuchen; Chen, Xiaodong; Li, Yuhua; Zheng, Bin; Li, Shibo; Chen, Wei R.; Liu, Hong

    2012-09-01

    In digital pathology, clinical specimen slides are converted into digital images by microscopic image scanners. Since random vibration and mechanical drifting are unavoidable on even high-precision moving stages, the optical depth of field (DOF) of microscopic systems may affect image quality, in particular when using an objective lens with high magnification power. The DOF of a microscopic system was theoretically analyzed and experimentally validated using standard resolution targets under 60× dry and 100× oil objective lenses, respectively. Then cytogenetic samples were imaged at in-focused and off-focused states to analyze the impact of DOF on the acquired image qualities. For the investigated system equipped with the 60× dry and 100× oil objective lenses, the theoretical estimation of the DOF are 0.855 μm and 0.703 μm, and the measured DOF are 3.0 μm and 1.8 μm, respectively. The observation reveals that the chromosomal bands of metaphase cells are distinguishable when images are acquired up to approximately 1.5 μm or 1 μm out of focus using the 60× dry and 100× oil objective lenses, respectively. The results of this investigation provide important designing trade-off parameters to optimize the digital microscopic image scanning systems in the future.

  20. Developing a more useful surface quality metric for laser optics

    Science.gov (United States)

    Turchette, Quentin; Turner, Trey

    2011-02-01

    Light scatter due to surface defects on laser resonator optics produces losses which lower system efficiency and output power. The traditional methodology for surface quality inspection involves visual comparison of a component to scratch and dig (SAD) standards under controlled lighting and viewing conditions. Unfortunately, this process is subjective and operator dependent. Also, there is no clear correlation between inspection results and the actual performance impact of the optic in a laser resonator. As a result, laser manufacturers often overspecify surface quality in order to ensure that optics will not degrade laser performance due to scatter. This can drive up component costs and lengthen lead times. Alternatively, an objective test system for measuring optical scatter from defects can be constructed with a microscope, calibrated lighting, a CCD detector and image processing software. This approach is quantitative, highly repeatable and totally operator independent. Furthermore, it is flexible, allowing the user to set threshold levels as to what will or will not constitute a defect. This paper details how this automated, quantitative type of surface quality measurement can be constructed, and shows how its results correlate against conventional loss measurement techniques such as cavity ringdown times.

  1. Qualities and Inequalities in Online Social Networks through the Lens of the Generalized Friendship Paradox.

    Science.gov (United States)

    Momeni, Naghmeh; Rabbat, Michael

    2016-01-01

    The friendship paradox is the phenomenon that in social networks, people on average have fewer friends than their friends do. The generalized friendship paradox is an extension to attributes other than the number of friends. The friendship paradox and its generalized version have gathered recent attention due to the information they provide about network structure and local inequalities. In this paper, we propose several measures of nodal qualities which capture different aspects of their activities and influence in online social networks. Using these measures we analyse the prevalence of the generalized friendship paradox over Twitter and we report high levels of prevalence (up to over 90% of nodes). We contend that this prevalence of the friendship paradox and its generalized version arise because of the hierarchical nature of the connections in the network. This hierarchy is nested as opposed to being star-like. We conclude that these paradoxes are collective phenomena not created merely by a minority of well-connected or high-attribute nodes. Moreover, our results show that a large fraction of individuals can experience the generalized friendship paradox even in the absence of a significant correlation between degrees and attributes.

  2. Spinning pipe gas lens revisited

    CSIR Research Space (South Africa)

    Mafusire, C

    2008-01-01

    Full Text Available , there is little information on optical phase aberrations and no study to date on the propagation parameters of the laser beam, but has rather remained rooted in the domain of ray optics. Researchers revisit the spinning pipe gas lens in this paper with new...

  3. A new optical antennas based on fiber coupling system and aspherical optical system

    Science.gov (United States)

    Wang, Ye; Tian, Shaohua

    2013-08-01

    Space Laser communication is a new technology in recent years of optical communications, optical antenna is a communications front receiving system, compose of the optical antenna receiver, optical fiber coupling lenses. Optical antenna to receive as much as possible the signal light from the target of free space, In this paper, 10.6μm wavelength of infrared light for communication wave, we use spherical mirror and aspheric lens combination of the system, Design of large diameter concave mirror to collect more laser energy, After another spherical convex mirror reflection again to aspherical lens, then coupled into the fiber. The aspheric lens can be a good feature to correct aberration, so this design has less transmission loss and high coupling efficiency. Using Zemax software, we setting reasonable energy analysis and image quality evaluation, design spherical mirrors and aspherical refractive lenses optical system, has good optical performance and economy, can be apply on the atmospheric Laser communication the receiving device.

  4. Photographic zoom fisheye lens design for DSLR cameras

    Science.gov (United States)

    Yan, Yufeng; Sasian, Jose

    2017-09-01

    Photographic fisheye lenses with fixed focal length for cameras with different sensor formats have been well developed for decades. However, photographic fisheye lenses with variable focal length are rare on the market due in part to the greater design difficulty. This paper presents a large aperture zoom fisheye lens for DSLR cameras that produces both circular and diagonal fisheye imaging for 35-mm sensors and diagonal fisheye imaging for APS-C sensors. The history and optical characteristics of fisheye lenses are briefly reviewed. Then, a 9.2- to 16.1-mm F/2.8 to F/3.5 zoom fisheye lens design is presented, including the design approach and aberration control. Image quality and tolerance performance analysis for this lens are also presented.

  5. Electrowetting liquid lens array on curved substrates for wide field of view image sensor

    Science.gov (United States)

    Bang, Yousung; Lee, Muyoung; Won, Yong Hyub

    2016-03-01

    In this research, electrowetting liquid lens array on curved substrates is developed for wide field of view image sensor. In the conventional image sensing system, this lens array is usually in the form of solid state. However, in this state, the lens array which is similar to insect-like compound eyes in nature has several limitations such as degradation of image quality and narrow field of view because it cannot adjust focal length of lens. For implementation of the more enhanced system, the curved array of lenses based on electrowetting effect is developed in this paper, which can adjust focal length of lens. The fabrication of curved lens array is conducted upon the several steps, including chamber fabrication, electrode & dielectric layer deposition, liquid injection, and encapsulation. As constituent materials, IZO coated convex glass, UV epoxy (NOA 68), DI water, and dodecane are used. The number of lenses on the fabricated panel is 23 by 23 and each lens has 1mm aperture with 1.6mm pitch between adjacent lenses. When the voltage is applied on the device, it is observed that each lens is changed from concave state to convex state. From the unique optical characteristics of curved array of liquid lenses such as controllable focal length and wide field of view, we can expect that it has potential applications in various fields such as medical diagnostics, surveillance systems, and light field photography.

  6. A course in lens design

    CERN Document Server

    Velzel, Chris

    2014-01-01

    A Course in Lens Design is an instruction in the design of image-forming optical systems. It teaches how a satisfactory design can be obtained in a straightforward way. Theory is limited to a minimum, and used to support the practical design work. The book introduces geometrical optics, optical instruments and aberrations. It gives a description of the process of lens design and of the strategies used in this process. Half of its content is devoted to the design of sixteen types of lenses, described in detail from beginning to end. This book is different from most other books on lens design because it stresses the importance of the initial phases of the design process: (paraxial) lay-out and (thin-lens) pre-design. The argument for this change of accent is that in these phases much information can be obtained about the properties of the lens to be designed. This information can be used in later phases of the design. This makes A Course in Lens Design a useful self-study book, and a suitable basis for an intro...

  7. Tethered capsule OCT endomicroscopy for upper gastrointestinal tract imaging by using ball lens probe (Conference Presentation)

    Science.gov (United States)

    Dong, Jing; Gora, Michalina J.; Reddy, Rohith; Trasischker, Wolfgang; Poupart, Oriane; Lu, Weina; Carruth, Robert W.; Grant, Catriona N.; Soomro, Amna R.; Tiernan, Aubrey R.; Rosenberg, Mireille; Nishioka, Norman S.; Tearney, Guillermo J.

    2016-03-01

    While endoscopy is the most commonly used modality for diagnosing upper GI tract disease, this procedure usually requires patient sedation that increases cost and mandates its operation in specialized settings. In addition, endoscopy only visualizes tissue superfically at the macroscopic scale, which is problematic for many diseases that manifest below the surface at a microscopic scale. Our lab has previously developed technology termed tethered capsule OCT endomicroscopy (TCE) to overcome these diagnostic limitations of endoscopy. The TCE device is a swallowable capsule that contains optomechanical components that circumferentially scan the OCT beam inside the body as the pill traverses the organ via peristalsis. While we have successfully imaged ~100 patients with the TCE device, the optics of our current device have many elements and are complex, comprising a glass ferrule, optical fiber, glass spacer, GRIN lens and prism. As we scale up manufacturing of this device for clinical translation, we must decrease the cost and improve the manufacturability of the capsule's optical configuration. In this abstract, we report on the design and development of simplificed TCE optics that replace the GRIN lens-based configuration with an angle-polished ball lens design. The new optics include a single mode optical fiber, a glass spacer and an angle polished ball lens, that are all fusion spliced together. The ball lens capsule has resolutions that are comparable with those of our previous GRIN lens configuration (30µm (lateral) × 7 µm (axial)). Results in human subjects show that OCT-based TCE using the ball lens not only provides rapid, high quality microstructural images of upper GI tract, but also makes it possible to implement this technology inexpensively and on a larger scale.

  8. Visualization of the macula during elective pars plana vitrectomy in the presence of a dual-optic accommodating intraocular lens.

    Science.gov (United States)

    Marques, Eduardo F; Ferreira, Tiago B; Castanheira-Dinis, António

    2014-05-01

    We describe the case of a 69-year-old patient who had pars plana vitrectomy (PPV) for epiretinal membrane removal 18 months after cataract surgery with implantation of a dual-optic accommodating IOL (Synchrony). During PPV, visualization of the macula was perfect, and the postoperative visual outcome was excellent. To our knowledge, this is the first report of retinal visualization during PPV in the presence of a dual-optic accommodating IOL. When choosing a presbyopia-correcting IOL, surgeons should consider the advantage of macula visualization with an IOL with monofocal optics. Dr. Marques is a consultant to Abbott Medical Optics, Inc. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  9. Construction of a numerically controlled device for aligning optical and mechanical axis of a microscope lens on a lathe

    Science.gov (United States)

    Juranek, H. J.

    1981-02-01

    In microscope manufacturing lenses are normally cemented in special mounts. The optical axis is aligned to the mechanical axis by a turning operation on a special lathe. Solutions to automate this process are presented.

  10. Analysis of a time-lens based optical frame synchronizer and retimer for 10G Ethernet aiming at a Tb/s optical router/switch design

    DEFF Research Database (Denmark)

    Laguardia Areal, Janaina; Hu, Hao; Peucheret, Christophe

    2010-01-01

    This paper analyzes experimentally and by numerical simulations an optical frame retimer and synchronizer unit for 10 Gbit/s Ethernet input frames. The unit is envisaged to be applied in the design of an optically transparent router for Optical Time Division Multiplexed (OTDM) links, aggregating...... traffic from several 10 Gbit/s Ethernet (10 GE) links. The scheme is based on time-lenses implemented through a combination of a sinusoidally driven optical phase modulation and linear dispersion. Our analysis extracts the operation range of the scheme used for synchronization and retiming in the context...

  11. Non-thermal electromagnetic radiation damage to lens epithelium.

    Science.gov (United States)

    Bormusov, Elvira; P Andley, Usha; Sharon, Naomi; Schächter, Levi; Lahav, Assaf; Dovrat, Ahuva

    2008-05-21

    High frequency microwave electromagnetic radiation from mobile phones and other modern devices has the potential to damage eye tissues, but its effect on the lens epithelium is unknown at present. The objective of this study was to investigate the non-thermal effects of high frequency microwave electromagnetic radiation (1.1GHz, 2.22 mW) on the eye lens epithelium in situ. Bovine lenses were incubated in organ culture at 35°C for 10-15 days. A novel computer-controlled microwave source was used to investigate the effects of microwave radiation on the lenses. 58 lenses were used in this study. The lenses were divided into four groups: (1) Control lenses incubated in organ culture for 10 to15 days. (2) Electromagnetic radiation exposure group treated with 1.1 GHz, 2.22 mW microwave radiation for 90 cycles of 50 minutes irradiation followed by 10 minutes pause and cultured up to 10 days. (3) Electromagnetic radiation exposure group treated as group 2 with 192 cycles of radiation and cultured for 15 days. (4) Lenses exposed to 39.5°C for 2 hours 3 times with 24 hours interval after each treatment beginning on the second day of the culture and cultured for 11 days. During the culture period, lens optical quality was followed daily by a computer-operated scanning laser beam. At the end of the culture period, control and treated lenses were analyzed morphologically and by assessment of the lens epithelial ATPase activity. Exposure to 1.1 GHz, 2.22 mW microwaves caused a reversible decrease in lens optical quality accompanied by irreversible morphological and biochemical damage to the lens epithelial cell layer. The effect of the electromagnetic radiation on the lens epithelium was remarkably different from those of conductive heat. The results of this investigation showed that electromagnetic fields from microwave radiation have a negative impact on the eye lens. The lens damage by electromagnetic fields was distinctly different from that caused by conductive heat.

  12. Thermal Lens Microscope

    Science.gov (United States)

    Uchiyama, Kenji; Hibara, Akihide; Kimura, Hiroko; Sawada, Tsuguo; Kitamori, Takehiko

    2000-09-01

    We developed a novel laser microscope based on the thermal lens effect induced by a coaxial beam comprised of excitation and probe beams. The signal generation mechanism was confirmed to be an authentic thermal lens effect from the measurement of signal and phase dependences on optical configurations between the sample and the probe beam focus, and therefore, the thermal lens effect theory could be applied. Two-point spatial resolution was determined by the spot size of the excitation beam, not by the thermal diffusion length. Sensitivity was quite high, and the detection ability, evaluated using a submicron microparticle containing dye molecules, was 0.8 zmol/μm2, hence a distribution image of trace chemical species could be obtained quantitatively. In addition, analytes are not restricted to fluorescent species, therefore, the thermal lens microscope is a promising analytical microscope. A two-dimensional image of a histamine molecule distribution, which was produced in mast cells at the femtomole level in a human nasal mucous polyp, was obtained.

  13. Lens Model

    DEFF Research Database (Denmark)

    Nash, Ulrik William

    2014-01-01

    Firms consist of people who make decisions to achieve goals. How do these people develop the expectations which underpin the choices they make? The lens model provides one answer to this question. It was developed by cognitive psychologist Egon Brunswik (1952) to illustrate his theory...

  14. Investigation of optical properties of an overdense magnetized plasma lens in the interaction with high-intensity Gaussian laser pulses

    Science.gov (United States)

    Ghorbanalilu, M.; Shokri, B.

    2018-03-01

    Self-focusing of a high-intensity circularly polarized Gaussian laser pulse by an overdense magnetized thin plasma lens is numerically investigated. The quasi-static axial magnetic field can be produced by inverse Faraday effect (IFE) mechanism in laser-plasma interaction. It has been shown that the inclusion of self-transparency, ponderomotive force, and magnetic field effects significantly affect the self-focusing properties. When the strength of the magnetic field increases, the self-focusing property is enhanced for the right and is weakened for the left-handed circularly polarized laser pulse. The ponderomotive force repels electrons from the axis and drives electron cavitation and as a result further lowers the plasma frequency. When the influence of the ponderomotive force is taken into account, self-focusing for both polarizations is strongly affected. The clear difference between the effects of the right- and left-handed circularly polarized pulses may lead us to use them for different experimental applications.

  15. Multiplane optical microscope

    Energy Technology Data Exchange (ETDEWEB)

    Li, Tongcang; Ota, Sadao; Kim, Jeongmin; Wang, Yuan; Zhang, Xiang

    2017-11-21

    This disclosure provides systems, methods, and apparatus related to optical microscopy. In one aspect, an apparatus includes a sample holder, a first objective lens, a plurality of optical components, a second objective lens, and a mirror. The apparatus may directly image a cross-section of a sample oblique to or parallel to the optical axis of the first objective lens, without scanning.

  16. Primary anterior chamber intraocular lens for the treatment of severe crystalline lens subluxation.

    Science.gov (United States)

    Hoffman, Richard S; Fine, I Howard; Packer, Mark

    2009-10-01

    Subluxated cataractous and clear lenses are commonly treated by limbal or pars plana lensectomy followed by primary or secondary intraocular lens (IOL) implantation. Adjunctive capsular prosthetic devices have facilitated lens removal and IOL centration in these challenging cases but have also added complexity and potential complications to the procedure. Although crystalline lens extraction may be required to clear the visual axis in mild to moderate lens subluxations, we propose insertion of a primary anterior chamber IOL without lens extraction in severe subluxations when the eye is optically aphakic or can be made functionally aphakic following neodymium:YAG laser zonulysis. Two cases demonstrating this approach are presented.

  17. Water quality determination by photographic analysis. [optical density and water turbidity

    Science.gov (United States)

    Klooster, S. A.; Scherz, J. P.

    1973-01-01

    Aerial reconnaissance techniques to extract water quality parameters from aerial photos are reported. The turbidity can be correlated with total suspended solids if the constituent parts of the effluent remain the same and the volumetric flow remains relatively constant. A monochromator is used for the selection of the bandwidths containing the most information. White reflectance panels are used to locate sampling points and eliminate inherent energy changes from lens flare, radial lens fall-off, and changing subject illumination. Misleading information resulting from bottom effects is avoided by the use of Secchi disc readings and proper choice of wavelength for analyzing the photos.

  18. Probing graphene defects and estimating graphene quality with optical microscopy

    International Nuclear Information System (INIS)

    Lai, Shen; Kyu Jang, Sung; Jae Song, Young; Lee, Sungjoo

    2014-01-01

    We report a simple and accurate method for detecting graphene defects that utilizes the mild, dry annealing of graphene/Cu films in air. In contrast to previously reported techniques, our simple approach with optical microscopy can determine the density and degree of dislocation of defects in a graphene film without inducing water-related damage or functionalization. Scanning electron microscopy, confocal Raman and atomic force microscopy, and X-ray photoelectron spectroscopy analysis were performed to demonstrate that our nondestructive approach to characterizing graphene defects with optimized thermal annealing provides rapid and comprehensive determinations of graphene quality

  19. Scatter radiation dose at height of the lens and image quality in interventional cardiology; Nivel de radiacao na altura do cristalino em cardiologia intervencionista

    Energy Technology Data Exchange (ETDEWEB)

    Leguees, Fernando A. Leyton

    2016-07-01

    Cardiologist and other staff members receive high doses of scattered radiation. Cases of radiation-induced cataract among cardiology professionals have been reported in studies, estimates for the dose to eye lens ranged from 450 to 900 mSv per year (without ceiling suspended screen), over several years. Recent surveys regarding high prevalence of lens changes likely induced by radiation exposure suggest an urgent need for improved radiation safety and training, use of eye protection during catheterization procedures, and improved occupational dosimetry. In view of the evidence of radiation injuries, the ICRP recommends limiting the radiation dose to the lens to 20 mSv per year for occupational exposure. A system for optimizing the radiation exposure is the measurement of entrance surface air kerma (K{sub a,e}) and kerma-area product (P{sub KA}) for patient and scattered dose or dose rate at the position for the staff, under clinical working conditions using phantoms and defined technical factors. Correlating K{sub a,e} and P{sub KA} with the scatter dose, applying the attenuation factors protective devices can enable estimation of the lens doses for operators. The purpose of this work is: to study the possibility of establishing a procedure which is useful for scientific societies and the regulatory authority in the prevention and control of IOE dose and to control and improve the quality of procedures in interventional cardiology as an initiative to raise awareness and optimization of radiological protection. Measurements were taken in different cardiac laboratories. Clinical working conditions were reproduced during the experiments for the different hemodynamic angiographic projections and operating modes used in fluoroscopy and cine. A first K{sub a,e} rate reference proposal for the characterization of angiography for the different acquisition modes were 16; 35; 40 and 220 (mGy/min), respectively. Considering the typical PKA values to patient in interventional

  20. Double-beam optical method and apparatus for measuring thermal diffusivity and other molecular dynamic processes in utilizing the transient thermal lens effect

    International Nuclear Information System (INIS)

    Gupta, A.; Hong, S.; Moacanin, J.

    1981-01-01

    A method and apparatus for measuring thermal diffusivity and molecular relaxation processes in a sample material utilizing two light beams, one being a pulsed laser light beam for forming a thermal lens in the sample material, and the other being a relatively low power probe light beam for measuring changes in the refractive index of the sample material during formation and dissipation of the thermal lens. More specifically, a sample material is irradiated by relatively high power, short pulses from a dye laser. Energy from the pulses is absorbed by the sample material, thereby forming a thermal lens in the area of absorption. The pulse repetition rate is chosen so that the thermal lens is substantially dissipated by the time the next pulse reaches the sample material. A probe light beam, which in a specific embodiment is a relatively low power, continuous wave (Cw) laser beam, irradiates the thermal lens formed in the sample material. The intensity characteristics of the probe light beam subsequent to irradiation of the thermal lens is related to changes in the refractive index of the sample material as the thermal lens is formed and dissipated. A plot of the changes in refractive index as a function of time during formation of the thermal lens as reflected by changes in intensity of the probe beam, provides a curve related to molecular relaxation characteristics of the material, and a plot during dissipation of the thermal lens provides a curve related to the thermal diffusivity of the sample material

  1. APPROACH TO AUTOMATION OF LENS COMPONENTS CENTERING FOR ASSEMBLING OF DIFFERENT DESIGN OBJECTIVES

    Directory of Open Access Journals (Sweden)

    A. Y. Pimenov

    2016-01-01

    Full Text Available Subject of Research.Existing adjustment methods of lens objectives in two mechanical designs have been analyzed, the main ways of centering error compensation have been considered. The algorithm of automated search of optical elements position has been developed based on the existing methods of centering for compensation of residual decentering. The methods of joint application of this algorithm and centering machine “Trioptics Opticentric” have been suggested. Method. Centering errors of the objective lens components are measured on the centering machine. Aberrations of optical system are calculated by using the received data of centering errors entered to the objective mathematical model. For the calculation of aberration compensation, iteration algorithm of searching of optical elements optimal position is used. The image quality is analyzed for each obtained realization of the optical system. The result of program performance is data matrix about optical components location such that compensation of residual aberrations occurs. Based on the obtained information the system assembling is carried out with the use of centering machine “Trioptics Opticentric”. Main Results. Computer modeling of centering errors for 100 lens apochromatic objectives of drop-in mountings lens design has been carried out. The coma of object axial point image has been chosen as quality estimation criterion. The developed algorithm has been applied for the worst realization of the optical system. In this case the value of integral coma of object axial point image has been decreased by two orders and reduced practically to zero. It is noted that the modeling of adjustment process via using the algorithm of automated search enables to predict the possibility of objective assembly with required quality parameters. Practical Relevance. The received results can be applied on the lines of automated assembly of modern lens objectives.

  2. Optical design of two-axes parabolic trough collector and two-section Fresnel lens for line-to-spot solar concentration.

    Science.gov (United States)

    Ramírez, Carlos; León, Noel; García, Héctor; Aguayo, Humberto

    2015-06-01

    Solar tracking concentrators are optical systems that collect the solar energy flux either in a line or spot using reflective or refractive surfaces. The main problem with these surfaces is their manufacturing complexity, especially at large scales. In this paper, a line-to-spot solar tracking concentrator is proposed. Its configuration allows for a low-cost solar concentrator system. It consists of a parabolic trough collector (PTC) and a two-section PMMA Fresnel lens (FL), both mounted on a two-axis solar tracker. The function of the PTC is to reflect the incoming solar radiation toward a line. Then, the FL, which is placed near the focus, transforms this line into a spot by refraction. It was found that the system can achieve a concentration ratio of 100x and concentrate an average solar irradiance of 518.857W/m2 with an average transmittance of 0.855, taking into account the effect of the chromatic aberration.

  3. The correct lens mount lightweighting design and thermal stress OPD analysis in Cassegrain telescope

    Science.gov (United States)

    Hsu, Ming-Ying; Chan, Chia-Yen; Lin, Wei-Cheng; Chang, Shenq-Tsong; Huang, Ting-Ming

    2013-09-01

    This study is trying to evaluate different lens barrel material, caused lens stress OPD (Optical Path Different) in different temperature condition. The Cassegrain telescope's correct lens assembly are including as correct lens, lens mount, spacer, mount barrel and retainer. The lens barrel initial design is made by invar, but system mass limit is need to lightweighting to meet requirement. Therefore, the lens barrel material is tried to replace to lower density material, such as aluminum and titanium alloy. Meanwhile, the aluminum or titanium alloy material properties CTE (Coefficient of Thermal Expansion) are larger then invar. Thus, the high CTE material will introduce larger thermal stress into the optical system in different temperature condition. This article is analysis the correct lens assembly thermal stress and optical performance in different lens mount material. From above conditions, using FEM (Finite Element Method) and optical software, simulation and optimization the lens mount to achieve system mass requirement.

  4. Quality of Rapeseed Bio-Fuel Waste: Optical Properties

    Science.gov (United States)

    Sujak, Agnieszka; Muszyñski, Siemowit; Kachel-Jakubowska, Magdalena

    2014-04-01

    The objective of the presented work was to examine the optical properties of selected bio-fuel waste. Three independent optical methods: UV-Vis spectroscopy, infrared spectroscopy and chromametric measurements were applied to establish the possible quality control test for the obtained substances. The following by-products were tested: distilled glycerine, technical glycerine and matter organic non glycerine fraction from rapeseed oil bio-fuel production. The results show that analysis of UV-Vis spectra can give rapid information about the purity of distilled glycerine, while no direct information can be obtained concerning the concentration and kind of impurities. Transmission mode is more useful as compared to absorption, concerning the detection abilities of average UV-Vis spectrometers. Infrared spectroscopy can be used as a complementary method for determining impurities/admixtures in samples. Measurements of chroma give the quickest data to compare the colour of biofuel by-products obtained by different producers. The condition is, however, that the products are received through the same or similar chemical processes. The other important factor is application of well defined measuring background. All the discussed analyses are quick, cheap and non-destructive, and can help to compare the quality of products.

  5. Night Vision Goggles Objectives Lens Focusing Methodology

    National Research Council Canada - National Science Library

    Pinkus, Alan; Task, H. L

    2000-01-01

    ...: interpupillary distance, tilt, eye relief, height, eyepiece and objective lens focus. Currently, aircrew use a Hoffman 20/20 test unit to pre-focus their NVG objective lenses at optical infinity before boarding their aircraft...

  6. Polymer micromolds with near optical quality surface finishes

    Science.gov (United States)

    Shiu, Pun-Pang; Knopf, George K.; Nikumb, Suwas

    2012-03-01

    Disposable microfluidic systems are used to avoid sample contamination in a variety of medical and environmental monitoring applications. A contactless hot intrusion (HI) process for fabricating reusable polymer micromolds with near "optical quality" surface finishes is described in this paper. A metallic hot intrusion mask with the desired microchannels and related passive components is first machined using a tightly focused beam from a diode-pumped solid-state (DPSS) laser. The polymer mold master is then created by pressing the 2D metallic mask onto a polymethylmethacrylate (PMMA) substrate. Since it is a contactless fabrication process the resultant 3D micro-reliefs have near optical quality surface finishes. Unfortunately, the desired micro-relief dimensions (height and width) are not easily related to the hot intrusion process parameters of pressure, temperature, and time exposure profile. A finite element model is introduced to assist the manufacturing engineer in predicting the behavior of the PMMA substrate material as it deforms under heat and pressure during micromold manufacture. The FEM model assumes that thermo-plastics like PMMA become "rubber like" when heated to a temperature slightly above the glass transition temperature. By controlling the material temperature and maintaining its malleable state, it is possible to use the stress-strain relationship to predict the profile dimensions of the imprinted microfeature. Examples of curved microchannels fabricated using PMMA mold masters are presented to illustrate the proposed methodology and verify the finite element model. In addition, the non-contact formation of the micro-reliefs simplifies the demolding process and helps to preserve the high quality surface finishes.

  7. Optical analysis of lens-like Cu{sub 2}CdSnS{sub 4} quaternary alloy nanostructures

    Energy Technology Data Exchange (ETDEWEB)

    Odeh, Ali Abu; Ayub, R.M. [University Malaysia Perlis, Institute of Nano Electronic Engineering, Kangar, Perlis (Malaysia); Al-Douri, Y. [University Malaysia Perlis, Institute of Nano Electronic Engineering, Kangar, Perlis (Malaysia); University of Sidi-Bel-Abbes, Physics Department, Faculty of Science, Sidi-Bel-Abbes (Algeria); Ameri, M. [Universite Djilali Liabes de Sidi Bel- Abbes, Laboratoire Physico-Chimie des Materiaux Avances (LPCMA), Sidi-Bel-Abbes (Algeria); Bouhemadou, A. [University of Setif 1, Laboratory for Developing New Materials and Their Characterization, Setif (Algeria); Prakash, Deo [SMVD University, Faculty of Engineering, School of Computer Science and Engineering, Kakryal, Katra, J and K (India); Verma, K.D. [S.V. College, Material Science Research Laboratory, Department of Physics, Aligarh, U.P. (India)

    2016-10-15

    Cu{sub 2}CdSnS{sub 4} quaternary alloy nanostructures with different copper concentrations (0.2, 0.4, 0.6, 0.8 and 1.0 M) were successfully synthesized on n-type silicon substrates using spin coating technique with annealing temperature at 300 C. Optical properties were analyzed through UV-Vis and Photoluminescence spectroscopies, and thus, there is a change in energy band gap with increasing Cu concentration from 0.2 to 1.0 M. The structural properties of Cu{sub 2}CdSnS{sub 4} quaternary alloy nanostructures were investigated by X-ray diffraction. The particles size and shape have a direct relationship with copper concentration. Morphological and topographical studies were carried out by using scanning electron microscopy and atomic force microscopy. The obtained results are investigated to be available in the literature for future studies. (orig.)

  8. Study on the improvement of overall optical image quality via digital image processing

    Science.gov (United States)

    Tsai, Cheng-Mu; Fang, Yi Chin; Lin, Yu Chin

    2008-12-01

    This paper studies the effects of improving overall optical image quality via Digital Image Processing (DIP) and compares the promoted optical image with the non-processed optical image. Seen from the optical system, the improvement of image quality has a great influence on chromatic aberration and monochromatic aberration. However, overall image capture systems-such as cellphones and digital cameras-include not only the basic optical system but also many other factors, such as the electronic circuit system, transducer system, and so forth, whose quality can directly affect the image quality of the whole picture. Therefore, in this thesis Digital Image Processing technology is utilized to improve the overall image. It is shown via experiments that system modulation transfer function (MTF) based on the proposed DIP technology and applied to a comparatively bad optical system can be comparable to, even possibly superior to, the system MTF derived from a good optical system.

  9. Research on the processing technology of medium-caliber aspheric lens in the optoelectronic integrated test system

    Science.gov (United States)

    Liu, Dan; Yu, Xin-ying; Wang, Wei

    2016-10-01

    In the optoelectronic integrated test system, surface profile and finish of the optical element are put forward higher request. Taking an aspherical quartz glass lens with a diameter of 200mm as example, taking Preston hypothesis as the theoretical basis, analyze the influence of surface quality of various process parameters, including the workpiece and the tool axis spindle speed, wheel type, concentration polishing, polishing mold species, dwell time, polishing pressure and other parameters. Using CNC method for the surface profile and surface quality of the lens were investigated. Taking profilometer measurement results as a guide, by testing and simulation analysis, process parameters were improved constantly in the process of manufacturing. Mid and high frequency error were trimmed and improved so that the surface form gradually converged to the required accuracy. The experimental results show that the final accuracy of the surface is less than 2µm and the surface finish is, which fulfils the accuracy requirement of aspherical focusing lens in optical system.

  10. Accuracy of intraocular lens power calculation using three optical biometry measurement devices: the OA-2000, Lenstar-LS900 and IOLMaster-500.

    Science.gov (United States)

    Reitblat, Olga; Levy, Adi; Kleinmann, Guy; Assia, Ehud I

    2018-03-12

    To compare ocular measurements of three optical biometry devices and their application in intraocular lens (IOL) power calculations. One hundred and forty eyes which had undergone cataract extraction surgery with preoperative biometry with OA--2000, IOLMaster-500, and Lenstar-LS900 were enrolled. Biometry measurements of the three devices were compared. The deviation of the postoperative refraction from the preoperative refractive target was calculated with different formulas (Barrett Universal II, Hoffer Q, Holladay I, and SRK/T). Errors in the predicted astigmatism using the Barrett toric calculator were calculated for the toric IOLs. Additional 6465 eyes in which the IOLMaster-500 failed to measure axial length (AL) were reviewed. The percentage of successful measurements using the OA-2000 in those eyes was calculated. High agreement was found between the three devices for AL, anterior chamber depth, and average keratometry measurements (interclass correlation confidents: 1.000, 0.970, and 0.998, respectively, P 2000 yielded a lower against-the-rule (ATR) centroid error in the predicted astigmatism than the IOLMaster-500 and Lenstar-LS900 (0.06 D ± 0.59 at 13.4° vs. 0.20 D ± 0.61 at 14.8° and 0.16 D ± 0.55 at 21.4°, respectively, P 2000 had 284 (94.35%) successful measurements. The OA-2000 measurements showed good agreement with those of the IOLMaster-500 and Lenstar-LS900. Our results may suggest a potential advantage of the OA-2000 device in toric IOLs calculations and AL measurement success rate.

  11. Optical Coherence Tomography–Based Corneal Power Measurement and Intraocular Lens Power Calculation Following Laser Vision Correction (An American Ophthalmological Society Thesis)

    Science.gov (United States)

    Huang, David; Tang, Maolong; Wang, Li; Zhang, Xinbo; Armour, Rebecca L.; Gattey, Devin M.; Lombardi, Lorinna H.; Koch, Douglas D.

    2013-01-01

    Purpose: To use optical coherence tomography (OCT) to measure corneal power and improve the selection of intraocular lens (IOL) power in cataract surgeries after laser vision correction. Methods: Patients with previous myopic laser vision corrections were enrolled in this prospective study from two eye centers. Corneal thickness and power were measured by Fourier-domain OCT. Axial length, anterior chamber depth, and automated keratometry were measured by a partial coherence interferometer. An OCT-based IOL formula was developed. The mean absolute error of the OCT-based formula in predicting postoperative refraction was compared to two regression-based IOL formulae for eyes with previous laser vision correction. Results: Forty-six eyes of 46 patients all had uncomplicated cataract surgery with monofocal IOL implantation. The mean arithmetic prediction error of postoperative refraction was 0.05 ± 0.65 diopter (D) for the OCT formula, 0.14 ± 0.83 D for the Haigis-L formula, and 0.24 ± 0.82 D for the no-history Shammas-PL formula. The mean absolute error was 0.50 D for OCT compared to a mean absolute error of 0.67 D for Haigis-L and 0.67 D for Shammas-PL. The adjusted mean absolute error (average prediction error removed) was 0.49 D for OCT, 0.65 D for Haigis-L (P=.031), and 0.62 D for Shammas-PL (P=.044). For OCT, 61% of the eyes were within 0.5 D of prediction error, whereas 46% were within 0.5 D for both Haigis-L and Shammas-PL (P=.034). Conclusions: The predictive accuracy of OCT-based IOL power calculation was better than Haigis-L and Shammas-PL formulas in eyes after laser vision correction. PMID:24167323

  12. Computer-aided lens assembly

    Science.gov (United States)

    Tomlinson, Richard; Alcock, Rob; Petzing, Jon; Coupland, Jeremy

    2004-01-01

    We propose a computer-aided method of lens manufacture that allows assembly, adjustment, and test phases to be run concurrently until an acceptable level of optical performance is reached. Misalignment of elements within a compound lens is determined by a comparison of the results of physical ray tracing by use of an array of Gaussian laser beams with numerically obtained geometric ray traces. An estimate of misalignment errors is made, and individual elements are adjusted in an iterative manner until performance criteria are achieved. The method is illustrated for the alignment of an air-spaced doublet.

  13. Particle swarm optimization applied to automatic lens design

    Science.gov (United States)

    Qin, Hua

    2011-06-01

    This paper describes a novel application of Particle Swarm Optimization (PSO) technique to lens design. A mathematical model is constructed, and merit functions in an optical system are employed as fitness functions, which combined radiuses of curvature, thicknesses among lens surfaces and refractive indices regarding an optical system. By using this function, the aberration correction is carried out. A design example using PSO is given. Results show that PSO as optical design tools is practical and powerful, and this method is no longer dependent on the lens initial structure and can arbitrarily create search ranges of structural parameters of a lens system, which is an important step towards automatic design with artificial intelligence.

  14. Panoramic lens applications revisited

    Science.gov (United States)

    Thibault, Simon

    2008-04-01

    During the last few years, innovative optical design strategies to generate and control image mapping have been successful in producing high-resolution digital imagers and projectors. This new generation of panoramic lenses includes catadioptric panoramic lenses, panoramic annular lenses, visible/IR fisheye lenses, anamorphic wide-angle attachments, and visible/IR panomorph lenses. Given that a wide-angle lens images a large field of view on a limited number of pixels, a systematic pixel-to-angle mapping will help the efficient use of each pixel in the field of view. In this paper, we present several modern applications of these modern types of hemispheric lenses. Recently, surveillance and security applications have been proposed and published in Security and Defence symposium. However, modern hemispheric lens can be used in many other fields. A panoramic imaging sensor contributes most to the perception of the world. Panoramic lenses are now ready to be deployed in many optical solutions. Covered applications include, but are not limited to medical imaging (endoscope, rigiscope, fiberscope...), remote sensing (pipe inspection, crime scene investigation, archeology...), multimedia (hemispheric projector, panoramic image...). Modern panoramic technologies allow simple and efficient digital image processing and the use of standard image analysis features (motion estimation, segmentation, object tracking, pattern recognition) in the complete 360° hemispheric area.

  15. A Model for the Effect of Disturbances in the Optical Media on the OCT Image Quality

    NARCIS (Netherlands)

    Kok, Pauline H. B.; van Dijk, Hille W.; van den Berg, Thomas J. T. P.; Verbraak, Frank D.

    2009-01-01

    PURPOSE. The loss of quality of optical coherence tomography (OCT) images resulting from disturbances in the optical media has been modeled. METHODS. OCT measurements were performed in two healthy volunteers using time domain (TD)-OCT (StratusOCT; Carl Zeiss Meditec, Dublin, CA). Optical

  16. The SNAP Strong Lens Survey

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, P.

    2005-01-03

    Basic considerations of lens detection and identification indicate that a wide field survey of the types planned for weak lensing and Type Ia SNe with SNAP are close to optimal for the optical detection of strong lenses. Such a ''piggy-back'' survey might be expected even pessimistically to provide a catalogue of a few thousand new strong lenses, with the numbers dominated by systems of faint blue galaxies lensed by foreground ellipticals. After sketching out our strategy for detecting and measuring these galaxy lenses using the SNAP images, we discuss some of the scientific applications of such a large sample of gravitational lenses: in particular we comment on the partition of information between lens structure, the source population properties and cosmology. Understanding this partitioning is key to assessing strong lens cosmography's value as a cosmological probe.

  17. Modern Phacoemulsification and Intraocular Lens Implantation (Refractive Lens Exchange) Is Safe and Effective in Treating High Myopia.

    Science.gov (United States)

    Srinivasan, Bhaskar; Leung, Hiu Ying; Cao, He; Liu, Shu; Chen, Lizhen; Fan, Alex Hoi

    Improved efficacy, predictability, and safety of modern phacoemulsification have resulted in cataract surgery being considered as a refractive procedure. Refractive lens exchange by definition is a surgery aimed at replacing the cataractous or clear crystalline lens with an intraocular lens (IOL) in cases of high ametropia. The excellent intraocular optics of this procedure provide a better visual outcome as compared with laser refractive surgery in high myopia. With advances in technology and IOL formulas, the predictability of refractive outcome after cataract surgery in high myopes has improved. The option of addressing presbyopia using multifocal/accommodating IOLs or monovision results in patients achieving reasonable spectacle independence. The most important concern with respect to phacoemulsification in high myopia is the risk of pseudophakic retinal detachment. High myopia is an independent risk factor for retinal detachment, and recent publications have reported a much lesser risk of retinal detachment specifically attributable to phacoemulsification in high myopes, especially if a thorough posterior segment evaluation is done and patients are followed up until development of complete posterior vitreous detachment. Refractive lens exchange is an effective and safe option to correct high myopia and can significantly improve quality of life in select patients.

  18. Contact lens in keratoconus

    Directory of Open Access Journals (Sweden)

    Varsha M Rathi

    2013-01-01

    Full Text Available Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP lenses, soft and soft toric lenses, piggy back contact lenses (PBCL, hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the English language with the keywords keratoconus and various contact lenses such as Rose k lens, RGP lens, hybrid lens, scleral lens and PBCL.

  19. Contact lens in keratoconus

    Science.gov (United States)

    Rathi, Varsha M; Mandathara, Preeji S; Dumpati, Srikanth

    2013-01-01

    Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP) lenses, soft and soft toric lenses, piggy back contact lenses (PBCL), hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the English language with the keywords keratoconus and various contact lenses such as Rose k lens, RGP lens, hybrid lens, scleral lens and PBCL. PMID:23925325

  20. Properties of the cathode lens combined with a focusing magnetic/immersion-magnetic lens

    International Nuclear Information System (INIS)

    Konvalina, I.; Muellerova, I.

    2011-01-01

    The cathode lens is an electron optical element in an emission electron microscope accelerating electrons from the sample, which serves as a source for a beam of electrons. Special application consists in using the cathode lens first for retardation of an illuminating electron beam and then for acceleration of reflected as well as secondary electrons, made in the directly imaging low energy electron microscope or in its scanning version discussed here. In order to form a real image, the cathode lens has to be combined with a focusing magnetic lens or a focusing immersion-magnetic lens, as used for objective lenses of some commercial scanning electron microscopes. These two alternatives are compared with regards to their optical properties, in particular with respect to predicted aberration coefficients and the spot size, as well as the optimum angular aperture of the primary beam. The important role of the final aperture size on the image resolution is also presented.

  1. Slide-position errors degrade machined optical component quality

    International Nuclear Information System (INIS)

    Arnold, J.B.; Steger, P.J.; Burleson, R.R.

    1975-01-01

    An ultraprecision lathe is being developed at the Oak Ridge Y-12 Plant to fabricate optical components for use in high-energy laser systems. The lathe has the capability to produce virtually any shape mirror which is symmetrical about an axis of revolution. Two basic types of mirrors are fabricated on the lathe, namely: (1) mirrors which are machined using a single slide motion (such as flats and cylinders), and (2) mirrors which are produced by two-coordinated slide motions (such as hyperbolic reflectors; large, true-radius reflectors, and other contoured-surface reflectors). The surface-finish quality of typical mirrors machined by a single axis of motion is better than 13 nm, peak to valley, which is an order of magnitude better than the surface finishes of mirrors produced by two axes of motion. Surface finish refers to short-wavelength-figure errors that are visibly detectable. The primary cause of the inability to produce significantly better surface finishes on contoured mirrors has been determined as positional errors which exist in the slide positioning systems. The correction of these errors must be accomplished before contoured surface finishes comparable to the flat and cylinder can be machined on the lathe

  2. Comparison of visual outcomes and subjective visual quality after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of apodized diffractive bifocal intraocular lenses

    Directory of Open Access Journals (Sweden)

    Gundersen KG

    2016-05-01

    Full Text Available Kjell G Gundersen,1 Rick Potvin21IFocus Øyeklinikk AS, Haugesund, Norway; 2Science in Vision, Akron, NY, USAPurpose: To compare the visual acuity (VA and quality of vision between bilateral implantation of a trifocal intraocular lens (IOL and blended bifocal IOLs with an intermediate add in the dominant eye and a near add in the nondominant eye.Patients and methods: Patients with either trifocal or blended bifocal IOLs implanted were recruited after surgery. Subjects returned for a single diagnostic visit between 3 and 24 months after surgery. VA was tested at various distances, including low-contrast acuity and acuity at their preferred reading distance. A binocular defocus curve was obtained, and subjective visual function and quality of vision were evaluated.Results: Twenty-five trifocal subjects and 30 blended bifocal subjects were enrolled. There were no significant differences in low-contrast acuity, preferred reading distance, or acuity at that reading distance. Binocular vision at 4 m, 60 cm, and 40 cm was not statistically significantly different. The trifocal provided statistically significantly better visual acuity (P<0.05 at vergences from -0.5 to -1.5 D (from 2 m to 67 cm viewing distance, P<0.05. There was no statistically significant difference in the near vision subscale scores of the 39-question National Eye Institute Visual Function Questionnaire or the overall scores of the Quality of Vision questionnaire, though significantly more trifocal subjects reported that the observed visual disturbances were “bothersome” (P<0.05.Conclusion: Both lens modalities provided subjects with excellent binocular near and distance vision, with similar low rates of visual disturbances and good reported functional vision. The trifocal IOL provided significantly better intermediate VA in the viewing distance range of 2 m to 67 cm, corresponding to viewing things such as a car dashboard or grocery shelf. VA was similar between groups at

  3. Evolution and the Calcite Eye Lens

    OpenAIRE

    Williams, Vernon L.

    2013-01-01

    Calcite is a uniaxial, birefringent crystal, which in its optically transparent form, has been used for animal eye lenses, the trilobite being one such animal. Because of the calcite birefringence there is a difficulty in using calcite as a lens. When the propagation direction of incoming light is not exactly on the c-axis, the mages blur. In this paper, calcite blurring is evaluated, and the non-blurring by a crystallin eye lens is compared to a calcite one.

  4. Quality Monitoring of Infrared Optics Using Ultrasound Signals

    Science.gov (United States)

    Neumeier, Benedikt; Schmitt-Landsiedel, Doris

    During laser processing with beam powers in the multi-kilowatt range a fraction of the emission is absorbed in optical elements, leading to thermal loading on the optics. This temperature rise of the optics results in thermal lensing, impairing the power density at the processing location. In a number of niche applications, the CO2 laser still is preferred over solid-state lasers due to its unrivaled features in processing materials like fused silica, glasses, wood, ceramics or plastics. Applying existing techniques to monitor the temperature of CO2 laser optics using pyrometers prove to be unreliable due to the transmissivity in the infrared of the optical materials used. The object of this study is experimental identification of temperature increase of ZnSe optics during use for processing in a laser cutting machine, and development of a method utilizing ultrasound to measure the temperature of the infrared optics. The method enables the testing of the absorption properties of infrared optics as well as solid-state laser optics.

  5. Peripheral myopization and visual performance with experimental rigid gas permeable and soft contact lens design.

    Science.gov (United States)

    Pauné, J; Queiros, A; Quevedo, L; Neves, H; Lopes-Ferreira, D; González-Méijome, J M

    2014-12-01

    To evaluate the performance of two experimental contact lenses (CL) designed to induce relative peripheral myopic defocus in myopic eyes. Ten right eyes of 10 subjects were fitted with three different CL: a soft experimental lens (ExpSCL), a rigid gas permeable experimental lens (ExpRGP) and a standard RGP lens made of the same material (StdRGP). Central and peripheral refraction was measured using a Grand Seiko open-field autorefractometer across the central 60° of the horizontal visual field. Ocular aberrations were measured with a Hartman-Shack aberrometer, and monocular contrast sensitivity function (CSF) was measured with a VCTS6500 without and with the three contact lenses. Both experimental lenses were able to increase significantly the relative peripheral myopic defocus up to -0.50 D in the nasal field and -1.00 D in the temporal field (p0.05). RGP lens design seems to be more effective to induce a significant myopic change in the relative peripheral refractive error. Both lenses preserve a good visual performance. The worsened optical quality observed in ExpRGP was due to an increased coma-like and spherical-like HOA. However, no impact on the visual quality as measured by CSF was observed. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  6. The Optical Design of the Human Eye: a Critical Review

    Directory of Open Access Journals (Sweden)

    Rafael Navarro

    2009-01-01

    Full Text Available Cornea, lens and eye models are analyzed and compared to experimental findings to assess properties and eventually unveil optical design principles involved in the structure and function of the optical system of the eye. Models and data often show good match but also some paradoxes. The optical design seems to correspond to a wide angle lens. Compared to conventional optical systems, the eye presents a poor optical quality on axis, but a relatively good quality off-axis, thus yielding higher homogeneity for a wide visual field. This seems the result of an intriguing combination of the symmetry design principle with a total lack of rotational symmetry, decentrations and misalignments of the optical surfaces.

  7. Tube entrance lens focus control

    Science.gov (United States)

    Weisser, D. C.; Fifield, L. K.; Kitchen, T. F. G.; Tunningley, T. B.; Lobanov, N. R.; Muirhead, A. G.

    2013-02-01

    The entrance of the accelerator tube in a large electrostatic accelerator imposes a strong lens that dominates the beam optics. The magnification of the lens is large because of the low injection energy, the high voltage gradient of the acceleration tube and the long distance to the terminal. In the absence of the acceleration, the magnification would produce an unacceptably large beam spot at the terminal. The tyranny of the lens is especially irksome when the accelerator is required to operate at a lower terminal voltage than the one corresponding to the nominal gradient at high voltage. One way around the difficulty, used in NEC Pelletron accelerators, is to insert a series of nylon and steel rods that short together units of the acceleration structure at the terminal leaving the ones near the entrance close to the nominal gradient for optimum transmission. This operation takes time and risks the loss of insulating gas. Another alternative used in the 25URC at Oak Ridge National Laboratory, is to focus the beam at the tube entrance, substantially diluting the effect of the entrance lens. The beam then diverges and so requires an additional lens part way to the terminal. This solution is only partially effective and still necessitates use of shorting rods for low voltage operation. The fact that these elaborate strategies are used is evidence that the alternative of lowering the injection energy as the terminal voltage is lowered imposes enough problems that it is not used in practice. We have modeled a solution that controls the voltage gradient at the tube entrance using an external power supply. This not only maintains the focusing effect of the lens but provides the opportunity to tune the beam by adjusting the entrance lens. A 150 kV power supply outside the pressure vessel feeds a controllable voltage through a high voltage feed-through to the fifth electrode of the accelerator tube. Thus 150 kV on this electrode creates the nominal gradient of 30 kV per

  8. Multi-scale optical metrology for the quality control of polymer microfluidic systems

    DEFF Research Database (Denmark)

    Tosello, Guido; Marinello, Francesco; Hansen, Hans Nørgaard

    2009-01-01

    Micro injection moulding is a replication technology enabling large scale production of polymer-based micro products. To this respect, optical measuring technologies were selected to perform the quality control of a polymer micro-component: an optical coordinate measuring machine (CMM) and a white...

  9. High quality ZnO layers with adjustable refractive indices for integrated optics applications

    NARCIS (Netherlands)

    Heideman, Rene; Lambeck, Paul; Gardeniers, Johannes G.E.

    1995-01-01

    Thin (approx. 1 μm) crystalline ZnO films with a good optical quality and a good (0002) texture are grown under two considerably different process parameter sets using a r.f. planar magnetron sputtering unit. The optical parameters of the two corresponding ZnO layers are distinctly different: high

  10. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... lens because they can be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, ... Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume Contacts May Contain Chemicals Harmful to Eyes ...

  11. ECTOPIC LENS EXTRACTION IN CHILDREN

    Directory of Open Access Journals (Sweden)

    Vladimir Pfeifer

    2002-12-01

    Full Text Available Background. Ectopia lentis continues to be a therapeutic challenge for ophthalmologists. It can occur as an isolated condition, after ocular trauma, in association with other ocular disorders, as part of a systemic mesodermal disease or a complication of general metabolic disorders. Minimal subluxation of the lens may cause no visual symptoms, but in more advanced cases serious optical disturbances arise. The most important is amblyopia. Surgical treatment options include iris manipulation, lens discission, aspiration, intracapsular or extracapsular extraction, and pars plana lensectomy. The choice of surgical technique remains controversial, in part because of the historically poor visual results and high rate of perioperative complications, including vitreous loss and retinal detachment.Methods. We describe a surgical technique based on the use of the Cionni endocapsular tension ring, dry irrigation aspiration of lens material, centration of the capsular bag and foldable intraocular lens implantation into the bag. With mentioned surgical technique 8 patients were operated; 4 boys and 4 girls, together 11 eyes.Results. The final BCVA after follow up period improved in 9 eyes and it remained the same as before operation in one eye. Statistical comparison of preoperative and postoperative visual acuities showed significant improvement. On the other hand there was no correlation between preoperative and postoperative visual acuity.Conclusions. This surgical procedure is an alternative approach in solving this challenging cases of ectopia lentis with good postoperative visual rehabilitation.

  12. Improved surface quality of anisotropically etched silicon {111} planes for mm-scale optics

    International Nuclear Information System (INIS)

    Cotter, J P; Hinds, E A; Zeimpekis, I; Kraft, M

    2013-01-01

    We have studied the surface quality of millimetre-scale optical mirrors produced by etching CZ and FZ silicon wafers in potassium hydroxide to expose the {111} planes. We find that the FZ surfaces have four times lower noise power at spatial frequencies up to 500 mm −1 . We conclude that mirrors made using FZ wafers have higher optical quality. (technical note)

  13. Development of a Laue lens for nuclear astrophysics

    International Nuclear Information System (INIS)

    Rousselle, Julien

    2011-01-01

    In this work, a new type of gamma-ray telescope is presented. It features a crystal diffraction lens that concentrates photons from a large photon collecting area onto a small detector. In such a Laue lens, a large number of crystals are disposed on concentric rings; each crystal can be considered as a little mirror which deviates gamma-rays through Bragg diffraction from the incident beam onto a common focal spot. The principle of the Laue lens for astrophysics was demonstrated with the balloon mission CLAIRE. The objective of this work was to develop the Laue Lens concept into a sensitive, space qualified optics for a future satellite mission. This contribution consisted of two main facets: a) finding appropriate crystal materials and improving the performance of the diffracting crystals, and b) develop a prototype segment for a space qualified lens. Exploring new diffracting media and improving the performance of individual crystals implied the development of numerical simulations of the diffraction process for various types of mosaic and CDP (Curved Diffraction Plane) crystals. These simulations were used to select suitable crystals to be grown and to be tested. Two different X-ray facilities were used to probe the crystalline quality of candidate materials: the European Synchrotron Radiation Facility (ESRF, France) and the high neutron flux reactor at ILL (France). During 10 beam-runs (and a total of 3 months of measurement), a large number of samples were tested, including Ag, Ir, Pt, Au, Pb, Rh, AsGa, SiGe, and Cu crystals. Outstanding performances were established for gold and silver crystals (>500 keV), Cu and Ge (300-500 keV) crystals and SiGe CDP (<300 keV) crystal. The second facet of this work consisted of designing, manufacturing and characterizing a prototype lens segment. This R and D program was completed in collaboration with the CNES and Thales Alenia Space. For a representative sample of metal and semiconductor crystals that were mounted on the

  14. National Ignition Facility quality assurance plan for laser materials and optical technology

    Energy Technology Data Exchange (ETDEWEB)

    Wolfe, C.R.

    1996-05-01

    Quality achievement is the responsibility of the line organizations of the National Ignition Facility (NIF) Project. This subtier Quality Assurance Plan (QAP) applies to activities of the Laser Materials & Optical Technology (LM&OT) organization and its subcontractors. It responds to the NIF Quality Assurance Program Plan (QAPP, L-15958-2, NIF-95-499) and Department of Energy (DOE) Order 5700.6C. This Plan is organized according to 10 Quality Assurance (QA) criteria and subelements of a management system as outlined in the NIF QAPP. This Plan describes how those QA requirements are met. This Plan is authorized by the Associate Project Leader for the LM&OT organization, who has assigned responsibility to the Optics QA engineer to maintain this plan, with the assistance of the NIF QA organization. This Plan governs quality-affecting activities associated with: design; procurement; fabrication; testing and acceptance; handling and storage; and installation of NIF Project optical components into mounts and subassemblies.

  15. Novel Scanning Lens Instrument for Evaluating Fresnel Lens Performance: Equipment Development and Initial Results (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Herrero, R.; Miller, D. C.; Kurtz, S. R.; Anton, I.; Sala, G.

    2013-07-01

    A system dedicated to the optical transmittance characterization of Fresnel lenses has been developed at NREL, in collaboration with the UPM. The system quantifies the optical efficiency of the lens by generating a performance map. The shape of the focused spot may also be analyzed to understand change in the lens performance. The primary instrument components (lasers and CCD detector) have been characterized to confirm their capability for performing optical transmittance measurements. Measurements performed on SoG and PMMA lenses subject to a variety of indoor conditions (e.g., UV and damp heat) identified differences in the optical efficiency of the evaluated lenses, demonstrating the ability of the Scanning Lens Instrument (SLI) to distinguish between the aged lenses.

  16. Effect of processing on the in vitro and in vivo protein quality of red and green lentils (Lens culinaris).

    Science.gov (United States)

    Nosworthy, Matthew G; Medina, Gerardo; Franczyk, Adam J; Neufeld, Jason; Appah, Paulyn; Utioh, Alphonsus; Frohlich, Peter; House, James D

    2018-02-01

    In order to determine the effect of extrusion, baking and cooking on the protein quality of red and green lentils, a rodent bioassay was conducted and compared to an in vitro method of protein quality determination. On average, the Protein Digestibility-Corrected Amino Acid Score of red lentils (55.0) was higher than that of green lentils (50.8). Extruded lentil flour had higher scores (63.01 red, 57.09 green) than either cooked (57.40 red, 52.92 green) or baked (53.84 red, 47.14 green) flours. The average Digestible Indispensable Amino Acid Score of red lentils (0.54) was higher than green lentils (0.49). The Protein Efficiency Ratio of the extruded lentil flours (1.30 red, 1.34 green) was higher than that of the baked flour (0.98 red, 1.09 green). A correlation was found between in vivo and in vitro methods of determining protein digestibility (R 2 =0.8934). This work could influence selection of processing method during product development. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. The World Optical Depth Research and Calibration Center (WORCC) quality assurance and quality control of GAW-PFR AOD measurements

    Science.gov (United States)

    Kazadzis, Stelios; Kouremeti, Natalia; Nyeki, Stephan; Gröbner, Julian; Wehrli, Christoph

    2018-02-01

    The World Optical Depth Research Calibration Center (WORCC) is a section within the World Radiation Center at Physikalisches-Meteorologisches Observatorium (PMOD/WRC), Davos, Switzerland, established after the recommendations of the World Meteorological Organization for calibration of aerosol optical depth (AOD)-related Sun photometers. WORCC is mandated to develop new methods for instrument calibration, to initiate homogenization activities among different AOD networks and to run a network (GAW-PFR) of Sun photometers. In this work we describe the calibration hierarchy and methods used under WORCC and the basic procedures, tests and processing techniques in order to ensure the quality assurance and quality control of the AOD-retrieved data.

  18. Objective lens simultaneously optimized for pupil ghosting, wavefront delivery and pupil imaging

    Science.gov (United States)

    Olczak, Eugene G (Inventor)

    2011-01-01

    An objective lens includes multiple optical elements disposed between a first end and a second end, each optical element oriented along an optical axis. Each optical surface of the multiple optical elements provides an angle of incidence to a marginal ray that is above a minimum threshold angle. This threshold angle minimizes pupil ghosts that may enter an interferometer. The objective lens also optimizes wavefront delivery and pupil imaging onto an optical surface under test.

  19. Wide-field computational imaging of pathology slides using lens-free on-chip microscopy.

    Science.gov (United States)

    Greenbaum, Alon; Zhang, Yibo; Feizi, Alborz; Chung, Ping-Luen; Luo, Wei; Kandukuri, Shivani R; Ozcan, Aydogan

    2014-12-17

    Optical examination of microscale features in pathology slides is one of the gold standards to diagnose disease. However, the use of conventional light microscopes is partially limited owing to their relatively high cost, bulkiness of lens-based optics, small field of view (FOV), and requirements for lateral scanning and three-dimensional (3D) focus adjustment. We illustrate the performance of a computational lens-free, holographic on-chip microscope that uses the transport-of-intensity equation, multi-height iterative phase retrieval, and rotational field transformations to perform wide-FOV imaging of pathology samples with comparable image quality to a traditional transmission lens-based microscope. The holographically reconstructed image can be digitally focused at any depth within the object FOV (after image capture) without the need for mechanical focus adjustment and is also digitally corrected for artifacts arising from uncontrolled tilting and height variations between the sample and sensor planes. Using this lens-free on-chip microscope, we successfully imaged invasive carcinoma cells within human breast sections, Papanicolaou smears revealing a high-grade squamous intraepithelial lesion, and sickle cell anemia blood smears over a FOV of 20.5 mm(2). The resulting wide-field lens-free images had sufficient image resolution and contrast for clinical evaluation, as demonstrated by a pathologist's blinded diagnosis of breast cancer tissue samples, achieving an overall accuracy of ~99%. By providing high-resolution images of large-area pathology samples with 3D digital focus adjustment, lens-free on-chip microscopy can be useful in resource-limited and point-of-care settings. Copyright © 2014, American Association for the Advancement of Science.

  20. A high excitation magnetic quadrupole lens quadruplet incorporating a single octupole lens for a low spherical aberration probe forming lens system

    Science.gov (United States)

    Dou, Yanxin; Jamieson, David N.; Liu, Jianli; Li, Liyi

    2018-03-01

    This paper describes the design of a new probe forming lens system consisting of a high excitation magnetic quadrupole lens quadruplet that incorporates a single magnetic octupole lens. This system achieves both a high demagnification and a low spherical aberration compared to conventional high excitation systems and is intended for deployment for the Harbin 300 MeV proton microprobe for applications in space science and ion beam therapy. This relative simplicity of the ion optical design to include a single octupole lens minimizes the risks associated with the constructional and operational precision usually needed for the probe forming lens system and this system could also be deployed in microprobe systems that operate with less magnetically rigid ions. The design of the new system is validated with reference to two independent ion optical computer codes.

  1. A lazy way to design infrared lens

    Science.gov (United States)

    Qiu, RongSheng; Wu, JianDong; Chen, LongJiang; Yu, Kun; Pang, HaoJun; Hu, BaiZhen

    2017-08-01

    We designed a compact middle-wave infrared (MWIR) lens with a large focal length ratio (about 1.5:1), used in the 3.7 to 4.8 μm range. The lens is consisted of a compact front group and a re-imaging group. Thanks to the compact front group configuration, it is possible to install a filter wheel mechanism in such a tight space. The total track length of the lens is about 50mm, which includes a 2mm thick protective window and a cold shield of 12mm. The full field of view of the lens is about 3.6°, and F number is less than 1.6, the image circle is about 4.6mm in diameter. The design performance of the lens reaches diffraction limitation, and doesn't change a lot during a temperature range of -40°C +60°C. This essay proposed a stepwise design method of infrared optical system guided by the qualitative approach. The method fully utilize the powerful global optimization ability, with a little effort to write code snippet in optical design software, frees optical engineer from tedious calculation of the original structure.

  2. Effects of photobleaching on selected advanced glycation end products in the human lens

    DEFF Research Database (Denmark)

    Holm, Thomas; Raghavan, Cibin T; Nahomi, Rooban

    2015-01-01

    BackgroundCataract is the leading cause of blindness, especially in the developing world. To ease access to treatment, we have proposed that cataract could be treated non-invasively by photobleaching of the chemically modified proteins responsible for cataract formation. The present study was aimed...... at examining the optical and biochemical effects of the proposed treatment.MethodsHuman donor lenses were photobleaced using a 445 nm cw laser. Lens optical quality was assessed before and after photobleaching by light transmission and scattering. The concentration of the advanced glycation end products (AGEs...

  3. Visual Quality Assessment of Posterior Capsule Opacification Using Optical Quality Analysis System (OQAS

    Directory of Open Access Journals (Sweden)

    Hui Zhang

    2017-01-01

    Full Text Available Objective. To evaluate intraocular scattering in eyes with posterior capsule opacification by means of an objective scatter index (OSI obtained from double-pass images of optical quality assessment system (OQAS TM II and to determine the indication for laser capsulotomy when patients report visual disturbances without decreased visual acuity. Methods. In this prospective, observational, and nonconsecutive case series study, a total of 32 eyes of 29 patients are diagnosed with posterior capsule opacification after age-associated cataract were analyzed. Patient examination included age, the period after cataract surgery, logMAR best corrected visual acuity (BCVA, and OSI. Results. We found a significant decrease in the BCVA and increase in the OSI with the development of posterior capsule opacification. The decrease of BCVA was statistically correlated with the increase of OSI (r=0.812, P<0.01. In patients who reported visual disturbances without decreased visual acuity, OSI decreased to <1.3 and subjective symptoms were resolved in all cases although there was no significant improvement in visual acuity after laser capsulotomy. Conclusions. The results of our study showed that OSI is also a useful parameter for objectively evaluating posterior capsule opacification. OSI may help predict laser capsulotomy in patients who report visual disturbances without decreased visual acuity.

  4. Effect of Mycorrhizal Inoculation and Grain Priming on Some Quantity and Quality Properties of Lentil (Lens culinaris L.

    Directory of Open Access Journals (Sweden)

    mohsen azarnia

    2017-02-01

    Full Text Available Introduction: The most important problems of farmers in arid and semi-arid regions are adequate nutrition, optimum rooting, emergence, establishment and optimal density, and ultimately plant yield. Using grain priming and mycorrhizal inoculation is effective strategies in these conditions. Priming can cause earlier growth of seedling, to increase emergence rate, emergence percentage, plant tolerance to drought and salinity stress, early flowering as well as to increase the quality and quantity of yield and nutrient absorption. Plant hormones such as salicylic acid and gibberellic acid can be used for priming. Regarding plant response to environmental stresses, salicylic acid, which is an important signal molecule, plays a key role in the regulation of several physiological processes such as growth and plant development, absorption of ions, emergence and photosynthesis. Gibberellic acid (GA3 has been shown to be involved in many physiological processes such as cell division activity of meristem regions, increase the cell length, emergence speed, and emergence percentage, seedling growth in field condition, early flowering and yield. Mycorrhizal inoculation increases the availability of nutrients especially plant phosphorus, concentrations of plant hormones (auxins, cytokinins and gibberellins, chlorophyll content, the efficiency of biological nitrogen fixation, assimilates allocation to host plant organs, the changes of root structure, and improve soil structure. Materials and Methods: In order to evaluate the response of lentil to grain priming (without grain priming, hydro-priming, 100 ppm gibberellic acid, 100 ppm salicylic acid, 100 ppm gibberellic acid + 100 ppm salicylic acid and soil mycorrhizal inoculation (non-inoculated control, inoculated with Glomus moseae and Glomus intraradices, a factorial experiment based on a completely randomized block design with four replications carried out in a greenhouse and research farm of the Gonbad

  5. Optical design of an athermalised dual field of view step zoom optical system in MWIR

    Science.gov (United States)

    Kucukcelebi, Doruk

    2017-08-01

    In this paper, the optical design of an athermalised dual field of view step zoom optical system in MWIR (3.7μm - 4.8μm) is described. The dual field of view infrared optical system is designed based on the principle of passive athermalization method not only to achieve athermal optical system but also to keep the high image quality within the working temperature between -40°C and +60°C. The infrared optical system used in this study had a 320 pixel x 256 pixel resolution, 20μm pixel pitch size cooled MWIR focal plane array detector. In this study, the step zoom mechanism, which has the axial motion due to consisting of a lens group, is considered to simplify mechanical structure. The optical design was based on moving a single lens along the optical axis for changing the optical system's field of view not only to reduce the number of moving parts but also to athermalize for the optical system. The optical design began with an optimization process using paraxial optics when first-order optics parameters are determined. During the optimization process, in order to reduce aberrations, such as coma, astigmatism, spherical and chromatic aberrations, aspherical surfaces were used. As a result, athermalised dual field of view step zoom optical design is proposed and the performance of the design using proposed method was verified by providing the focus shifts, spot diagrams and MTF analyzes' plots.

  6. Nonlinear optical refraction of Al2O3 single crystal doping with nickel nanoparticles measured by the Kerr-lens autocorrelation technique

    International Nuclear Information System (INIS)

    Yu, Xiangxiang; Wang, Yuhua; Wang, Yumei

    2014-01-01

    The nonlinear refraction of a nickel doped α-Al 2 O 3 single crystal was measured with a 800 nm pulse using the Kerr-lens autocorrelation technique. The sample was fabricated by ion implantation using a metal vapor vacuum arc ion source. The value of the nonlinear refractive index, n 2 , of the sample was determined to be 7.9 × 10 −16 cm 2 W −1 . The mechanisms of nonlinear refraction of the bulk material and the nanoparticles have been discussed through the UV–vis spectrum and supercontinuum spectra. (paper)

  7. Invited review article: the electrostatic plasma lens.

    Science.gov (United States)

    Goncharov, Alexey

    2013-02-01

    The fundamental principles, experimental results, and potential applications of the electrostatic plasma lens for focusing and manipulating high-current, energetic, heavy ion beams are reviewed. First described almost 50 years ago, this optical beam device provides space charge neutralization of the ion beam within the lens volume, and thus provides an effective and unique tool for focusing high current beams where a high degree of neutralization is essential to prevent beam blow-up. Short and long lenses have been explored, and a lens in which the magnetic field is provided by rare-earth permanent magnets has been demonstrated. Applications include the use of this kind of optical tool for laboratory ion beam manipulation, high dose ion implantation, heavy ion accelerator injection, in heavy ion fusion, and other high technology.

  8. ESTIMATION OF INHERENT OPTICAL PROPERTIES AND THE WATER QUALITY COMPONENTS IN THE NEUSE RIVER-PAMLICO SOUND ESTUARINE SYSTEM

    Science.gov (United States)

    Field observations carried out in the Neuse River-Pamlico Sound Estuarine System (NRE-PS), North Carolina, USA were used to develop optical algorithms for assessing inherent optical properties, IOPs (absorption and backscattering) associated with water quality components (WQC).

  9. Asynchronous monitoring of the quality of multilevel optical PAM signals

    Science.gov (United States)

    Siuzdak, J.

    2017-08-01

    In the paper, there is analyzed the signal quality assessment method based on delay tap asynchronous sampling, both for binary and multilevel PAM signals. The obtained multilevel phase diagrams are far more complicated than binary ones. The phase diagrams are affected by the signal distortions but it is difficult to relate reliably the phase diagram form to the distortion type and its influence on the signal quality.

  10. Fibre-optical microendoscopy.

    Science.gov (United States)

    Gu, M; Bao, H; Kang, H

    2014-04-01

    Microendoscopy has been an essential tool in exploring micro/nano mechanisms in vivo due to high-quality imaging performance, compact size and flexible movement. The investigations into optical fibres, micro-scanners and miniature lens have boosted efficiencies of remote light delivery to sample site and signal collection. Given the light interaction with materials in the fluorescence imaging regime, this paper reviews two classes of compact microendoscopy based on a single fibre: linear optical microendoscopy and nonlinear optical microendoscopy. Due to the fact that fluorescence occurs only in the focal volume, nonlinear optical microendoscopy can provide stronger optical sectioning ability than linear optical microendoscopy, and is a good candidate for deep tissue imaging. Moreover, one-photon excited fluorescence microendoscopy as the linear optical microendoscopy suffers from severe photobleaching owing to the linear dependence of photobleaching rate on excitation laser power. On the contrary, nonlinear optical microendoscopy, including two-photon excited fluorescence microendoscopy and second harmonic generation microendoscopy, has the capability to minimize or avoid the photobleaching effect at a high excitation power and generate high image contrast. The combination of various nonlinear signals gained by the nonlinear optical microendoscopy provides a comprehensive insight into biophenomena in internal organs. Fibre-optical microendoscopy overcomes physical limitations of traditional microscopy and opens up a new path to achieve early cancer diagnosis and microsurgery in a minimally invasive and localized manner. © 2014 The Authors Journal of Microscopy © 2014 Royal Microscopical Society.

  11. Geometry-invariant gradient refractive index lens: analytical ray tracing.

    Science.gov (United States)

    Bahrami, Mehdi; Goncharov, Alexander V

    2012-05-01

    A new class of gradient refractive index (GRIN) lens is introduced and analyzed. The interior iso-indicial contours mimic the external shape of the lens, which leads to an invariant geometry of the GRIN structure. The lens model employs a conventional surface representation using a coincoid of revolution with a higher-order aspheric term. This model has a unique feature, namely, it allows analytical paraxial ray tracing. The height and the angle of an arbitrary incident ray can be found inside the lens in a closed-form expression, which is used to calculate the main optical characteristics of the lens, including the optical power and third-order monochromatic aberration coefficients. Moreover, due to strong coupling of the external surface shape to the GRIN structure, the proposed GRIN lens is well suited for studying accommodation mechanism in the eye. To show the power of the model, several examples are given emphasizing the usefulness of the analytical solution. The presented geometry-invariant GRIN lens can be used for modeling and reconstructing the crystalline lens of the human eye and other types of eyes featuring a GRIN lens.

  12. Vapor-transport growth of high optical quality WSe2 monolayers

    Directory of Open Access Journals (Sweden)

    Genevieve Clark

    2014-10-01

    Full Text Available Monolayer transition metal dichalcogenides are atomically thin direct-gap semiconductors that show a variety of novel electronic and optical properties with an optically accessible valley degree of freedom. While they are ideal materials for developing optical-driven valleytronics, the restrictions of exfoliated samples have limited exploration of their potential. Here, we present a physical vapor transport growth method for triangular WSe2 sheets of up to 30 μm in edge length on insulating SiO2 substrates. Characterization using atomic force microscopy and optical microscopy reveals that they are uniform, monolayer crystals. Low temperature photoluminescence shows well resolved and electrically tunable excitonic features similar to those in exfoliated samples, with substantial valley polarization and valley coherence. The monolayers grown using this method are therefore of high enough optical quality for routine use in the investigation of optoelectronics and valleytronics.

  13. REFRACTIVE NEUTRON LENS

    OpenAIRE

    Petrov, P. V.; Kolchevsky, N. N.

    2013-01-01

    Compound concave refractive lenses are used for focusing neutron beam. Investigations of spectral and focusing properties of a refractive neutron lens are presented. Resolution of the imaging system on the base of refractive neutron lenses depends on material properties and parameters of neutron source. Model of refractive neutron lens are proposed. Results of calculation diffraction resolution and focal depth of refractive neutron lens are discussed.

  14. Contact lens in keratoconus

    OpenAIRE

    Rathi, Varsha M; Mandathara, Preeji S; Dumpati, Srikanth

    2013-01-01

    Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP) lenses, soft and soft toric lenses, piggy back contact lenses (PBCL), hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the En...

  15. An adjustable electron achromat for cathode lens microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tromp, R.M., E-mail: rtromp@us.ibm.com [IBM T.J. Watson Research Center, 1101 Kitchawan Road, Yorktown Heights, NY 10598 (United States); Leiden Institute of Physics, Kamerlingh Onnes Laboratory, Niels Bohrweg 2, 2333 CA Leiden (Netherlands)

    2015-12-15

    Chromatic aberration correction in light optics began with the invention of a two-color-corrected achromatic crown/flint lens doublet by Chester Moore Hall in 1730. Such color correction is necessary because any single glass shows dispersion (i.e. its index of refraction changes with wavelength), which can be counteracted by combining different glasses with different dispersions. In cathode lens microscopes (such as Photo Electron Emission Microscopy – PEEM) we encounter a similar situation, where the chromatic aberration coefficient of the cathode lens shows strong dispersion, i.e. depends (non-linearly) on the energy with which the electrons leave the sample. Here I show how a cathode lens in combination with an electron mirror can be configured as an adjustable electron achromat. The lens/mirror combination can be corrected at two electron energies by balancing the settings of the electron mirror against the settings of the cathode lens. The achromat can be adjusted to deliver optimum performance, depending on the requirements of a specific experiment. Going beyond the achromat, an apochromat would improve resolution and transmission by a very significant margin. I discuss the requirements and outlook for such a system, which for now remains a wish waiting for fulfilment. - Highlights: • The properties of cathode objective lens plus electron mirror are discussed. • In analogy with light-optical achromats, cathode lens plus mirror can be configured as an electron achromat. • Unlike light optics, the electron achromat can be adjusted to best fulfill experimental requirements.

  16. The role of optical flow in automated quality assessment of full-motion video

    Science.gov (United States)

    Harguess, Josh; Shafer, Scott; Marez, Diego

    2017-09-01

    In real-world video data, such as full-motion-video (FMV) taken from unmanned vehicles, surveillance systems, and other sources, various corruptions to the raw data is inevitable. This can be due to the image acquisition process, noise, distortion, and compression artifacts, among other sources of error. However, we desire methods to analyze the quality of the video to determine whether the underlying content of the corrupted video can be analyzed by humans or machines and to what extent. Previous approaches have shown that motion estimation, or optical flow, can be an important cue in automating this video quality assessment. However, there are many different optical flow algorithms in the literature, each with their own advantages and disadvantages. We examine the effect of the choice of optical flow algorithm (including baseline and state-of-the-art), on motionbased automated video quality assessment algorithms.

  17. Wave aberration of human eyes and new descriptors of image optical quality and visual performance.

    Science.gov (United States)

    Lombardo, Marco; Lombardo, Giuseppe

    2010-02-01

    The expansion of wavefront-sensing techniques redefined the meaning of refractive error in clinical ophthalmology. Clinical aberrometers provide detailed measurements of the eye's wavefront aberration. The distribution and contribution of each higher-order aberration to the overall wavefront aberration in the individual eye can now be accurately determined and predicted. Using corneal or ocular wavefront sensors, studies have measured the interindividual and age-related changes in the wavefront aberration in the normal population with the goal of optimizing refractive surgery outcomes for the individual. New objective optical-quality metrics would lead to better use and interpretation of newly available information on aberrations in the eye. However, the first metrics introduced, based on sets of Zernike polynomials, is not completely suitable to depict visual quality because they do not directly relate to the quality of the retinal image. Thus, several approaches to describe the real, complex optical performance of human eyes have been implemented. These include objective metrics that quantify the quality of the optical wavefront in the plane of the pupil (ie, pupil-plane metrics) and others that quantify the quality of the retinal image (ie, image-plane metrics). These metrics are derived by wavefront aberration information from the individual eye. This paper reviews the more recent knowledge of the wavefront aberration in human eyes and discusses the image-quality and optical-quality metrics and predictors that are now routinely calculated by wavefront-sensor software to describe the optical and image quality in the individual eye. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  18. Development and evaluation of optical fiber NH3 sensors for application in air quality monitoring

    Science.gov (United States)

    Huang, Yu; Wieck, Lucas; Tao, Shiquan

    2013-02-01

    Ammonia is a major air pollutant emitted from agricultural practices. Sources of ammonia include manure from animal feeding operations and fertilizer from cropping systems. Sensor technologies with capability of continuous real time monitoring of ammonia concentration in air are needed to qualify ammonia emissions from agricultural activities and further evaluate human and animal health effects, study ammonia environmental chemistry, and provide baseline data for air quality standard. We have developed fiber optic ammonia sensors using different sensing reagents and different polymers for immobilizing sensing reagents. The reversible fiber optic sensors have detection limits down to low ppbv levels. The response time of these sensors ranges from seconds to tens minutes depending on transducer design. In this paper, we report our results in the development and evaluation of fiber optic sensor technologies for air quality monitoring. The effect of change of temperature, humidity and carbon dioxide concentration on fiber optic ammonia sensors has been investigated. Carbon dioxide in air was found not interfere the fiber optic sensors for monitoring NH3. However, the change of humidity can cause interferences to some fiber optic NH3 sensors depending on the sensor's transducer design. The sensitivity of fiber optic NH3 sensors was found depends on temperature. Methods and techniques for eliminating these interferences have been proposed.

  19. LENS: Science Scope and Development Stages

    Science.gov (United States)

    Vogelaar, R. Bruce

    2013-04-01

    The Low-Energy Neutrino Spectroscopy (LENS) experiment will resolve the solar metallicity question via measurement of the CNO neutrino flux, as well as test the predicted equivalence of solar luminosity as measured by photon versus neutrinos. The LENS detector uses charged-current interaction of neutrinos on Indium-115 (loaded in a scintillator, InLS) to reveal the complete solar neutrino spectrum. LENS's optically segmented 3D lattice geometry achieves precise time and spatial resolution and unprecedented background rejection and sensitivity for low-energy neutrino events. This first-of-a-kind lattice design is also suited for a range of other applications where high segmentation and large light collection are required (eg: sterile neutrinos with sources, double beta decay, and surface detection of reactor neutrinos). The physics scope, detector design, and logic driving the microLENS and miniLENS prototyping stages will be presented. The collaboration is actively running programs; building, operating, developing, and simulating these prototypes using the Kimballton Underground Research Facility (KURF). New members are welcome to the LENS Collaboration, and interested parties should contact R. Bruce Vogelaar.

  20. TESS Lens-Bezel Assembly Modal Testing

    Science.gov (United States)

    Dilworth, Brandon J.; Karlicek, Alexandra

    2017-01-01

    The Transiting Exoplanet Survey Satellite (TESS) program, led by the Kavli Institute for Astrophysics and Space Research at the Massachusetts Institute of Technology (MIT) will be the first-ever spaceborne all-sky transit survey. MIT Lincoln Laboratory is responsible for the cameras, including the lens assemblies, detector assemblies, lens hoods, and camera mounts. TESS is scheduled to be launched in August of 2017 with the primary goal to detect small planets with bright host starts in the solar neighborhood, so that detailed characterizations of the planets and their atmospheres can be performed. The TESS payload consists of four identical cameras and a data handling unit. Each camera consists of a lens assembly with seven optical elements and a detector assembly with four charge-coupled devices (CCDs) including their associated electronics. The optical prescription requires that several of the lenses are in close proximity to a neighboring element. A finite element model (FEM) was developed to estimate the relative deflections between each lens-bezel assembly under launch loads to predict that there are adequate clearances preventing the lenses from making contact. Modal tests using non-contact response measurements were conducted to experimentally estimate the modal parameters of the lens-bezel assembly, and used to validate the initial FEM assumptions. Key Words Non-contact measurements, modal analysis, model validation

  1. Metasurface axicon lens design at visible wavelengths

    Science.gov (United States)

    Alyammahi, Saleimah; Zhan, Qiwen

    2017-08-01

    The emerging field of metasurfaces is promising to realize novel optical devices with miniaturized flat format and added functionalities. Metasurfaces have been demonstrated to exhibit full control of amplitude, phase and polarization of electromagnetic waves. Using the metasurface, the wavefront of light can be manipulated permitting new functionalities such as focusing and steering of the beams and imaging. One optical component which can be designed using metasurfaces is the axicon. Axicons are conical lenses used to convert Gaussian beams into nondiffraction Bessel beams. These unique devices are utilized in different applications ranging from optical trapping and manipulation, medical imaging, and surgery. In this work, we study axicon lens design comprising of planar metasurfaces which generate non-diffracting Bessel beams at visible wavelengths. Dielectric metasurfaces have been used to achieve high efficiency and low optical loss. We measured the spot size of the resulted beams at different planes to demonstrate the non-diffraction properties of the resulted beams. We also investigated how the spot size is influenced by the axicon aperture. Furthermore, we examined the achromatic properties of the designed axicon. Comparing with the conventional lens, the metasurface axicon lens design enables the creation of flat optical device with wide range of depth of focus along its optical axis.

  2. Replication quality control of metal and polymer micro structured optical surfaces

    DEFF Research Database (Denmark)

    Gasparin, Stefania; Tosello, Guido; Hansen, Hans Nørgaard

    2011-01-01

    surfaces, quite often results in mirror-like surfaces which scatter the light and invalidate the optical measurements. This paper focuses on an analysis of a micro-structured optical component and the corresponding mould. A first investigation leads to a control of the manufacturing process through...... a control of the product. The purpose is to evaluate three critical dimensions. Results show that the difference of the measurements on different areas of the mould and the polymer component is approximately 4%. A second analysis focuses on the investigation of the optical component and its mould using...... replication methods based on polymer casting. The replica method is used in order to avoid damages of the structures and make feasible the measurement of optical specimens with non-contact instruments. Results show a quality replication equal to 95 - 99%. In both investigations the uncertainty...

  3. A novel, optical, on-line bacteria sensor for monitoring drinking water quality

    DEFF Research Database (Denmark)

    Højris, Bo; Christensen, Sarah Christine Boesgaard; Albrechtsen, Hans-Jørgen

    2016-01-01

    Today, microbial drinking water quality is monitored through either time-consuming laboratory methods or indirect on-line measurements. Results are thus either delayed or insufficient to support proactive action. A novel, optical, on-line bacteria sensor with a 10-minute time resolution has been...... conditions such as pollution events in drinking water....

  4. Improved quality of optical coherence tomography imaging of basal cell carcinomas using speckle reduction

    DEFF Research Database (Denmark)

    Mogensen, Mette; Jørgensen, Thomas Martini; Thrane, Lars

    2010-01-01

    suggests a method for improving OCT image quality for skin cancer imaging. EXPERIMENTAL DESIGN: OCT is an optical imaging method analogous to ultrasound. Two basal cell carcinomas (BCC) were imaged using an OCT speckle reduction technique (SR-OCT) based on repeated scanning by altering the distance between...

  5. Bio-optical water quality dynamics observed from MERIS in Pensacola Bay, Florida

    Science.gov (United States)

    Observed bio-optical water quality data collected from 2009 to 2011 in Pensacola Bay, Florida were used to develop empirical remote sensing retrieval algorithms for chlorophyll a (Chla), colored dissolved organic matter (CDOM), and suspended particulate matter (SPM). Time-series ...

  6. Fiber optic coupled optical sensor

    Science.gov (United States)

    Fleming, Kevin J.

    2001-01-01

    A displacement sensor includes a first optical fiber for radiating light to a target, and a second optical fiber for receiving light from the target. The end of the first fiber is adjacent and not axially aligned with the second fiber end. A lens focuses light from the first fiber onto the target and light from the target onto the second fiber.

  7. Camera, handlens, and microscope optical system for imaging and coupled optical spectroscopy

    Science.gov (United States)

    Mungas, Greg S. (Inventor); Boynton, John (Inventor); Sepulveda, Cesar A. (Inventor); Nunes de Sepulveda, legal representative, Alicia (Inventor); Gursel, Yekta (Inventor)

    2012-01-01

    An optical system comprising two lens cells, each lens cell comprising multiple lens elements, to provide imaging over a very wide image distance and within a wide range of magnification by changing the distance between the two lens cells. An embodiment also provides scannable laser spectroscopic measurements within the field-of-view of the instrument.

  8. Fabrication quality analysis of a fiber optic refractive index sensor created by CO2 laser machining.

    Science.gov (United States)

    Chen, Chien-Hsing; Yeh, Bo-Kuan; Tang, Jaw-Luen; Wu, Wei-Te

    2013-03-26

    This study investigates the CO2 laser-stripped partial cladding of silica-based optic fibers with a core diameter of 400 μm, which enables them to sense the refractive index of the surrounding environment. However, inappropriate treatments during the machining process can generate a number of defects in the optic fiber sensors. Therefore, the quality of optic fiber sensors fabricated using CO2 laser machining must be analyzed. The results show that analysis of the fiber core size after machining can provide preliminary defect detection, and qualitative analysis of the optical transmission defects can be used to identify imperfections that are difficult to observe through size analysis. To more precisely and quantitatively detect fabrication defects, we included a tensile test and numerical aperture measurements in this study. After a series of quality inspections, we proposed improvements to the existing CO2 laser machining parameters, namely, a vertical scanning pathway, 4 W of power, and a feed rate of 9.45 cm/s. Using these improved parameters, we created optical fiber sensors with a core diameter of approximately 400 μm, no obvious optical transmission defects, a numerical aperture of 0.52 ± 0.019, a 0.886 Weibull modulus, and a 1.186 Weibull-shaped parameter. Finally, we used the optical fiber sensor fabricated using the improved parameters to measure the refractive indices of various solutions. The results show that a refractive-index resolution of 1.8 × 10(-4) RIU (linear fitting R2 = 0.954) was achieved for sucrose solutions with refractive indices ranging between 1.333 and 1.383. We also adopted the particle plasmon resonance sensing scheme using the fabricated optical fibers. The results provided additional information, specifically, a superior sensor resolution of 5.73 × 10(-5) RIU, and greater linearity at R2 = 0.999.

  9. Enhanced optical power of GaN-based light-emitting diode with compound photonic crystals by multiple-exposure nanosphere-lens lithography

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yonghui; Wei, Tongbo, E-mail: tbwei@semi.ac.cn; Xiong, Zhuo; Shang, Liang; Tian, Yingdong; Zhao, Yun; Zhou, Pengyu; Wang, Junxi; Li, Jinmin [Semiconductor Lighting Technology Research and Development Center, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083 (China)

    2014-07-07

    The light-emitting diodes (LEDs) with single, twin, triple, and quadruple photonic crystals (PCs) on p-GaN are fabricated by multiple-exposure nanosphere-lens lithography (MENLL) process utilizing the focusing behavior of polystyrene spheres. Such a technique is easy and economical for use in fabricating compound nano-patterns. The optimized tilted angle is decided to be 26.6° through mathematic calculation to try to avoid the overlay of patterns. The results of scanning electron microscopy and simulations reveal that the pattern produced by MENLL is a combination of multiple ovals. Compared to planar-LED, the light output power of LEDs with single, twin, triple, and quadruple PCs is increased by 14.78%, 36.03%, 53.68%, and 44.85% under a drive current 350 mA, respectively. Furthermore, all PC-structures result in no degradation of the electrical properties. The stimulated results indicate that the highest light extraction efficiency of LED with the clover-shape triple PC is due to the largest scattering effect on propagation of light from GaN into air.

  10. Enhanced optical power of GaN-based light-emitting diode with compound photonic crystals by multiple-exposure nanosphere-lens lithography

    International Nuclear Information System (INIS)

    Zhang, Yonghui; Wei, Tongbo; Xiong, Zhuo; Shang, Liang; Tian, Yingdong; Zhao, Yun; Zhou, Pengyu; Wang, Junxi; Li, Jinmin

    2014-01-01

    The light-emitting diodes (LEDs) with single, twin, triple, and quadruple photonic crystals (PCs) on p-GaN are fabricated by multiple-exposure nanosphere-lens lithography (MENLL) process utilizing the focusing behavior of polystyrene spheres. Such a technique is easy and economical for use in fabricating compound nano-patterns. The optimized tilted angle is decided to be 26.6° through mathematic calculation to try to avoid the overlay of patterns. The results of scanning electron microscopy and simulations reveal that the pattern produced by MENLL is a combination of multiple ovals. Compared to planar-LED, the light output power of LEDs with single, twin, triple, and quadruple PCs is increased by 14.78%, 36.03%, 53.68%, and 44.85% under a drive current 350 mA, respectively. Furthermore, all PC-structures result in no degradation of the electrical properties. The stimulated results indicate that the highest light extraction efficiency of LED with the clover-shape triple PC is due to the largest scattering effect on propagation of light from GaN into air.

  11. Freeform micromachining of an infrared Alvarez lens

    Science.gov (United States)

    Smilie, Paul J.; Dutterer, Brian S.; Lineberger, Jennifer L.; Davies, Matthew A.; Suleski, Thomas J.

    2011-02-01

    In 1967, Luis Alvarez introduced a novel concept for a focusing lens whereby two transmitting elements with cubic polynomial surfaces yield a composite lens of variable focal length with small lateral shifts. Computer simulations have demonstrated the behavior of these devices, but fabricating the refractive cubic surfaces of the types needed with adequate precision and depth modulation has proven to be challenging using standard methods, and, to the authors' knowledge, Alvarez lens elements have not been previously machined in infrared materials. Recent developments in freeform diamond machining capability have enabled the fabrication of such devices. In this paper, we discuss the fabrication of freeform refractive Alvarez elements in germanium using diamond micro-milling on a five-axis Moore Nanotech® 350FG Freeform Generator. Machining approaches are discussed, and measurements of surface figure and finish are presented. Initial experimental tests of optical performance are also discussed.

  12. Estimate of the dose received in crystalline lens by pediatric interventional cardiologists

    International Nuclear Information System (INIS)

    Koren, C.; Alejo, L.; Serrada, A.

    2014-08-01

    The objective of this work is to estimate the maximum dose accumulated during one year in the crystalline lens of the pediatric interventional cardiologists that work in the Hospital Universitario La Paz. Optically Stimulated Luminescence Dosimeters (OSLDs) were used for to carry out this estimation, placed in the eyes of an anthropomorphic mannequin whose position in the room simulates the more habitual conditions of the clinical practice. Previously to the simulation, different tests to validate the used dosimetric system were realized, including those related with the stability, reproducibility and lector linearity, as well as the angular and energy dependence of the OSLDs. During the simulation the mannequin eyes were irradiated and were measured with OSLDs the rate of superficial equivalent dose in crystalline lens for the different qualities of beam habitually used, as much in fluoroscopy as in acquisition. With the obtained data during three years, corresponding to the fluoroscopy times and the acquisitions number of the interventional procedures carried out; as much therapeutic as diagnostic, and rate by measuring of obtained dose, has been considered the superficial equivalent dose and the equivalent dose at 3 mm deep accumulated in the crystalline lens of the pediatric interventional cardiologist with more work load of the Hospital, during the years 2011 and 2012. None of the obtained maximum values exceed the new dose annual limit in crystalline lens of 20 mSv, recommended by ICRP in April of 2011. (author)

  13. Quality assessment of packaged foods by optical oxygen sensing

    Science.gov (United States)

    Papkovsky, Dmitri B.; O'Mahony, Fiach C.; Kerry, Joe P.; Ogurtsov, Vladimir I.

    2005-11-01

    A phase-fluorometric oxygen sensor system has been developed, which allows non-destructive measurement of residual oxygen levels in sealed containers such as packaged foods. It operates with disposable solid-state sensors incorporated in each pack, and a portable detector which interrogates with the sensors through a (semi)transparent packaging material. The system has been optimized for packaging applications and validated in small and medium scale trials with different types of food, including MAP hams, cheese, convenience foods, smoked fish, bakery. It has demonstrated high efficiency in monitoring package integrity, oxygen profiles in packs, performance of packaging process and many other research and quality control tasks, allowing control of 100% of packs. The low-cost batch-calibrated sensors have demonstrated reliability, safety, stability including direct contact with food, high efficiency in the low oxygen range. Another system, which also employs the fluorescence-based oxygen sensing approach, provides rapid assessment of microbial contamination (total viable counts) in complex samples such as food homogenates, industrial waste, environmental samples, etc. It uses soluble oxygen-sensitive probes, standard microtitter plates and fluorescence measurements on conventional plate reader to monitor growth of aerobic bacteria in small test samples (e.g. food homogenates) via their oxygen respiration. The assay provides high sample through put, miniaturization, speed, and can serve as alternative to the established methods such as agar plate colony counts and turbidimetry.

  14. National Ignition Facility quality assurance plan for laser materials and optical technology

    International Nuclear Information System (INIS)

    Wolfe, C.R.

    1996-05-01

    Quality achievement is the responsibility of the line organizations of the National Ignition Facility (NIF) Project. This subtier Quality Assurance Plan (QAP) applies to activities of the Laser Materials ampersand Optical Technology (LM ampersand OT) organization and its subcontractors. It responds to the NIF Quality Assurance Program Plan (QAPP, L-15958-2, NIF-95-499) and Department of Energy (DOE) Order 5700.6C. This Plan is organized according to 10 Quality Assurance (QA) criteria and subelements of a management system as outlined in the NIF QAPP. This Plan describes how those QA requirements are met. This Plan is authorized by the Associate Project Leader for the LM ampersand OT organization, who has assigned responsibility to the Optics QA engineer to maintain this plan, with the assistance of the NIF QA organization. This Plan governs quality-affecting activities associated with: design; procurement; fabrication; testing and acceptance; handling and storage; and installation of NIF Project optical components into mounts and subassemblies

  15. Disposable optics for microscopy diagnostics.

    Science.gov (United States)

    Vilmi, Pauliina; Varjo, Sami; Sliz, Rafal; Hannuksela, Jari; Fabritius, Tapio

    2015-11-20

    The point-of-care testing (POCT) is having increasing role on modern health care systems due to a possibility to perform tests for patients conveniently and immediately. POCT includes lot of disposable devices because of the environment they are often used. For a disposable system to be reasonably utilized, it needs to be high in quality but low in price. Optics based POCT systems are interesting approach to be developed, and here we describe a low-cost fabrication process for microlens arrays for microscopy. Lens arrays having average lens diameter of 222 μm with 300 μm lens pitch were fabricated. The lenses were characterized to have standard deviation of 0.06 μm in height and 4.61 μm in diameter. The resolution limit of 3.9μm is demonstrated with real images, and the images were compared with ones made with glass and polycarbonate lens arrays. The image quality is at the same level than with the glass lenses and the manufacturing costs are very low, thus making them suitable for POCT applications.

  16. Development of quality assessment method for optically active food flavor chemicals.

    Science.gov (United States)

    Saito, Koichi; Hosono, Kouhei; Kitazawa, Nariko; Iwasaki, Yusuke; Ito, Rie; Nakazawa, Hiroyuki

    2011-01-01

    A quality assessment method for commercially available, optically active flavor compounds, namely, menthol, menthyl acetate, borneol, perillaldehyde, and 1,8-cineol, was developed. A gas chromatograph equipped with a flame ionization detector and a DB-5ms capillary column was used for the chemical purity test. A GC/MS with a beta-DEX cyclodextrin column was used for the optical purity test, by which the enantiomeric separation of each flavor compound was achieved. Enantiomeric excess was calculated as an expression of optical purity. Of the 25 standard samples subjected to the chemical purity test, six were found to have lower purity than the data provided by the manufacturers. When the same samples were subjected to the optical purity test, 11 were found to have lower purity than that indicated on the reagent labels. These results suggest that there is a need to conduct an optical purity test, in addition to a chemical purity test, for the quality assessment of flavor standards.

  17. Spherical aberration in contact lens wear.

    Science.gov (United States)

    Lindskoog Pettersson, A; Jarkö, C; Alvin, A; Unsbo, P; Brautaset, R

    2008-08-01

    The aim of the present studies was to investigate the effect on spherical aberration of different non custom-made contact lenses, both with and without aberration control. A wavefront analyser (Zywave, Bausch & Lomb) was used to measure the aberrations in each subject's right eye uncorrected and with the different contact lenses. The first study evaluated residual spherical aberration with a standard lens (Focus Dailies Disposable, Ciba Vision) and with an aberration controlled contact lens (ACCL) (Definition AC, Optical Connection Inc.). The second study evaluated the residual spherical aberrations with a monthly disposable silicone hydrogel lens with aberration reduction (PureVision, Bausch & Lomb). Uncorrected spherical aberration was positive for all pupil sizes in both studies. In the first study, residual spherical aberration was close to zero with the standard lens for all pupil sizes whereas the ACCL over-corrected spherical aberration. The results of the second study showed that the monthly disposable lens also over-corrected the aberration making it negative. The changes in aberration were statistically significant (plenses. Since the amount of aberration varies individually we suggest that aberrations should be measured with lenses on the eye if the aim is to change spherical aberration in a certain direction.

  18. Image science and image-quality research in the Optical Sciences Center

    Science.gov (United States)

    Barrett, Harrison H.; Myers, Kyle J.

    2014-09-01

    This paper reviews the history of research into imaging and image quality at the Optical Sciences Center (OSC), with emphasis on the period 1970-1990. The work of various students in the areas of psychophysical studies of human observers of images; mathematical model observers; image simulation and analysis, and the application of these methods to radiology and nuclear medicine is summarized. The rapid progress in computational power, at OSC and elsewhere, which enabled the steady advances in imaging and the emergence of a science of imaging, is also traced. The implications of these advances to ongoing research and the current Image Science curriculum at the College of Optical Sciences are discussed.

  19. Cleaving of TOPAS and PMMA microstructured polymer optical fibers: Core-shift and statistical quality optimization

    DEFF Research Database (Denmark)

    Stefani, Alessio; Nielsen, Kristian; Rasmussen, Henrik K.

    2012-01-01

    We fabricated an electronically controlled polymer optical fiber cleaver, which uses a razor-blade guillotine and provides independent control of fiber temperature, blade temperature, and cleaving speed. To determine the optimum cleaving conditions of microstructured polymer optical fibers (m......POFs) with hexagonal hole structures we developed a program for cleaving quality optimization, which reads in a microscope image of the fiber end-facet and determines the core-shift and the statistics of the hole diameter, hole-to-hole pitch, hole ellipticity, and direction of major ellipse axis. For 125μm in diameter...

  20. Origin of Improved Optical Quality of Monolayer Molybdenum Disulfide Grown on Hexagonal Boron Nitride Substrate.

    Science.gov (United States)

    Wan, Yi; Zhang, Hui; Wang, Wei; Sheng, Bowen; Zhang, Kun; Wang, Yilun; Song, Qingjun; Mao, Nannan; Li, Yanping; Wang, Xinqiang; Zhang, Jin; Dai, Lun

    2016-01-13

    Monolayer MoS2 is synthesized on hexagonal boron nitride (h-BN) flakes with a simple, high-yield method. Monolayer MoS2 on h-BN exhibits improved optical quality. Combining the theoretical and experimental analysis, it is concluded that the enhanced photoluminescence and Raman intensities of monolayer MoS2 probably originate from the relatively weak doping effect from the h-BN substrate rather than the optical interference effect. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Calculation of lens alignment errors using the ray transfer matrices for the lens assembly system with an autocollimator and a rotation stage

    Science.gov (United States)

    Chu, Jiyoung; Cho, Sungwhi; Joo, Won Don; Jang, Sangdon

    2017-08-01

    One of the most popular methods for high precision lens assembly of an optical system is using an autocollimator and a rotation stage. Some companies provide software for calculating the state of the lens along with their lens assembly systems, but the calculation algorithms used by the software are unknown. In this paper, we suggest a calculation method for lens alignment errors using ray transfer matrices. Alignment errors resulting from tilting and decentering of a lens element can be calculated from the tilts of the front and back surfaces of the lens. The tilt of each surface can be obtained from the position of the reticle image on the CCD camera of the autocollimator. Rays from a reticle of the autocollimator are reflected from the target surface of the lens, which rotates with the rotation stage, and are imaged on the CCD camera. To obtain a clear image, the distance between the autocollimator and the first lens surface should be adjusted according to the focusing lens of the autocollimator and the lens surfaces from the first to the target surface. Ray propagations for the autocollimator and the tilted lens surfaces can be expressed effectively by using ray transfer matrices and lens alignment errors can be derived from them. This method was compared with Zemax simulation for various lenses with spherical or flat surfaces and the error was less than a few percent.

  2. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... new application of artificial intelligence shows whether a patient’s eyes point to high blood pressure or risk ...

  3. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... ask for a prescription. There is no such thing as a "one size fits all" contact lens. ...

  4. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... had not been properly fitted by an eye care professional, the lenses stuck to my eye like ... lenses do not require the same level of care or consideration as a standard contact lens because ...

  5. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her ...

  6. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... Costume Contact Lenses Can Ruin Vision Eye Makeup Safety In fact, it is illegal to sell colored ...

  7. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... with Colored Contact Lenses Julian: Teenager Blinded In One Eye By Non-Prescription Contact Lens Laura: Vision ... Robyn: Blurry Vision and Daily Eye Drops After One Use Facts About Colored Contacts and Halloween Safety ...

  8. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of Service For ...

  9. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... in a pair of colored contact lenses, Laura Butler of Parkersburg, W.Va., had "extreme pain in ... to wear any kind of contact lens. In Butler's case, the lenses caused an infection and left ...

  10. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses ...

  11. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... an impulsive buy from a souvenir shop, but 10 hours after she first put in a pair ... Prescription Contact Lens Laura: Vision Loss After Just 10 Hours Robyn: Blurry Vision and Daily Eye Drops ...

  12. bubble chamber lens

    CERN Multimedia

    Before the days of electronic detectors, visual techniques were used to detect particles, using detectors such as spark chambers and bubble chambers. This plexiglass lens was used to focus the image of tracks so they could be photographed.

  13. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Contact Lens Facts Over-the-Counter Costume Contacts May Contain Chemicals Harmful to Eyes Four Ways Over- ... without a prescription are breaking the law, and may be fined $11,000 per violation. "Many of ...

  14. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not require the same level of care or consideration as a standard contact lens because they can ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ...

  15. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... an ophthalmologist — an eye medical doctor — who will measure each eye and talk to you about proper ...

  16. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... prescription. Follow the contact lens care directions for cleaning, disinfecting, and wearing the lenses. Never share contact ... with Industry Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  17. Design of LED projector based on gradient-index lens

    Science.gov (United States)

    Qian, Liyong; Zhu, Xiangbing; Cui, Haitian; Wang, Yuanhang

    2018-01-01

    In this study, a new type of projector light path is designed to eliminate the deficits of existing projection systems, such as complex structure and low collection efficiency. Using a three-color LED array as the lighting source, by means of the special optical properties of a gradient-index lens, the complex structure of the traditional projector is simplified. Traditional components, such as the color wheel, relay lens, and mirror, become unnecessary. In this way, traditional problems, such as low utilization of light energy and loss of light energy, are solved. With the help of Zemax software, the projection lens is optimized. The optimized projection lens, LED, gradient-index lens, and digital micromirror device are imported into Tracepro. The ray tracing results show that both the utilization of light energy and the uniformity are improved significantly.

  18. Dielectrically embedded flat mesh lens for millimeter waves applications.

    Science.gov (United States)

    Pisano, Giampaolo; Ng, Ming Wah; Ozturk, Fahri; Maffei, Bruno; Haynes, Vic

    2013-04-10

    A flat lens based on subwavelength periodic metal meshes has been developed using photolithographic techniques. These mesh grids are stacked at specific distances and embedded in polypropylene. A code was developed to optimize more than 1000 transmission line circuits required to vary the device phase shift across the lens flat surface, mimicking the behavior of a classical lens. A W-band mesh-lens prototype was successfully manufactured and its RF performance characterized using a vector network analyzer coupled to corrugated horn antennas. Co-polarization far-field beam patterns were measured and compared with finite-element method models. The excellent agreement between data and simulations validated our designing tools and manufacturing procedures. This mesh lens is a low-loss, robust, light, and compact device that has many potential applications including millimeter wave quasi-optical systems for future cosmic microwave background polarization instruments.

  19. Intra- and Intersession Repeatability of an Optical Quality and Intraocular Scattering Measurement System in Children.

    Directory of Open Access Journals (Sweden)

    Mi Tian

    Full Text Available To evaluate intra- and intersession repeatability of objective optical quality and intraocular scattering measurements with a double-pass system in children.Forty-two eyes of 42 children were included in the study. An optical quality analysis system (OQAS was used to measure optical quality parameters, including modulation transfer function cutoff frequency (MTFcutoff, Strehl ratio (SR, OQAS values (OV at 3 different contrasts and objective scatter index (OSI. Three measurement sessions with 10-min intervals were operated by the same technician, and in each session four consecutive measurements were obtained.Mean values for MTFcutoff, SR and OSI were 46.85 ± 7.45cpd, 0.27 ± 0.06 and 0.34 ± 0.22 respectively. 1 The intraclass correlation coefficients were ranged from 0.89 to 0.97 and coefficients of variation from 0.06 to 0.16 for all the parameters in the first session; the relative repeatability were 11.1% (MTFcutoff, 22.5% (SR, 10.9% (OV100%, 16.6% (OV2%, 22.4% (OV9% and 56.3% (OSI. Similar results were found in the second and third sessions. 2 Bland-Altman analysis showed that narrow 95% confidence intervals (compared between the first and second sessions ranged from -5.42 to 5.28 (MTFcutoff, -0.05 to 0.07 (SR, -0.18 to 0.18 (OV100%, -0.26 to 0.29 (OV20%, -0.33 to 0.39 (OV9% and -0.11 to 0.09 (OSI; the comparison between any two of the three sessions showed similar results.Measurements of optical quality and intraocular scattering in children by the double-pass system showed good intra- and intersession repeatability. Retinal image quality is high and intraocular scattering is low in children.

  20. Viscous froth lens

    Science.gov (United States)

    Green, T. E.; Bramley, A.; Lue, L.; Grassia, P.

    2006-11-01

    Microscale models of foam structure traditionally incorporate a balance between bubble pressures and surface tension forces associated with curvature of bubble films. In particular, models for flowing foam microrheology have assumed this balance is maintained under the action of some externally imposed motion. Recently, however, a dynamic model for foam structure has been proposed, the viscous froth model, which balances the net effect of bubble pressures and surface tension to viscous dissipation forces: this permits the description of fast-flowing foam. This contribution examines the behavior of the viscous froth model when applied to a paradigm problem with a particularly simple geometry: namely, a two-dimensional bubble “lens.” The lens consists of a channel partly filled by a bubble (known as the “lens bubble”) which contacts one channel wall. An additional film (known as the “spanning film”) connects to this bubble spanning the distance from the opposite channel wall. This simple structure can be set in motion and deformed out of equilibrium by applying a pressure across the spanning film: a rich dynamical behavior results. Solutions for the lens structure steadily propagating along the channel can be computed by the viscous froth model. Perturbation solutions are obtained in the limit of a lens structure with weak applied pressures, while numerical solutions are available for higher pressures. These steadily propagating solutions suggest that small lenses move faster than large ones, while both small and large lens bubbles are quite resistant to deformation, at least for weak applied back pressures. As the applied back pressure grows, the structure with the small lens bubble remains relatively stiff, while that with the large lens bubble becomes much more compliant. However, with even further increases in the applied back pressure, a critical pressure appears to exist for which the steady-state structure loses stability and unsteady

  1. Low-Cost Mobile Phone Microscopy with a Reversed Mobile Phone Camera Lens

    Science.gov (United States)

    Fletcher, Daniel A.

    2014-01-01

    The increasing capabilities and ubiquity of mobile phones and their associated digital cameras offer the possibility of extending low-cost, portable diagnostic microscopy to underserved and low-resource areas. However, mobile phone microscopes created by adding magnifying optics to the phone's camera module have been unable to make use of the full image sensor due to the specialized design of the embedded camera lens, exacerbating the tradeoff between resolution and field of view inherent to optical systems. This tradeoff is acutely felt for diagnostic applications, where the speed and cost of image-based diagnosis is related to the area of the sample that can be viewed at sufficient resolution. Here we present a simple and low-cost approach to mobile phone microscopy that uses a reversed mobile phone camera lens added to an intact mobile phone to enable high quality imaging over a significantly larger field of view than standard microscopy. We demonstrate use of the reversed lens mobile phone microscope to identify red and white blood cells in blood smears and soil-transmitted helminth eggs in stool samples. PMID:24854188

  2. Low-cost mobile phone microscopy with a reversed mobile phone camera lens.

    Directory of Open Access Journals (Sweden)

    Neil A Switz

    Full Text Available The increasing capabilities and ubiquity of mobile phones and their associated digital cameras offer the possibility of extending low-cost, portable diagnostic microscopy to underserved and low-resource areas. However, mobile phone microscopes created by adding magnifying optics to the phone's camera module have been unable to make use of the full image sensor due to the specialized design of the embedded camera lens, exacerbating the tradeoff between resolution and field of view inherent to optical systems. This tradeoff is acutely felt for diagnostic applications, where the speed and cost of image-based diagnosis is related to the area of the sample that can be viewed at sufficient resolution. Here we present a simple and low-cost approach to mobile phone microscopy that uses a reversed mobile phone camera lens added to an intact mobile phone to enable high quality imaging over a significantly larger field of view than standard microscopy. We demonstrate use of the reversed lens mobile phone microscope to identify red and white blood cells in blood smears and soil-transmitted helminth eggs in stool samples.

  3. Low-cost mobile phone microscopy with a reversed mobile phone camera lens.

    Science.gov (United States)

    Switz, Neil A; D'Ambrosio, Michael V; Fletcher, Daniel A

    2014-01-01

    The increasing capabilities and ubiquity of mobile phones and their associated digital cameras offer the possibility of extending low-cost, portable diagnostic microscopy to underserved and low-resource areas. However, mobile phone microscopes created by adding magnifying optics to the phone's camera module have been unable to make use of the full image sensor due to the specialized design of the embedded camera lens, exacerbating the tradeoff between resolution and field of view inherent to optical systems. This tradeoff is acutely felt for diagnostic applications, where the speed and cost of image-based diagnosis is related to the area of the sample that can be viewed at sufficient resolution. Here we present a simple and low-cost approach to mobile phone microscopy that uses a reversed mobile phone camera lens added to an intact mobile phone to enable high quality imaging over a significantly larger field of view than standard microscopy. We demonstrate use of the reversed lens mobile phone microscope to identify red and white blood cells in blood smears and soil-transmitted helminth eggs in stool samples.

  4. Enhancing optical power of GaN-based light-emitting diodes by nanopatterning on indium tin oxide with tunable fill factor using multiple-exposure nanosphere-lens lithography

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yonghui; Wei, Tongbo, E-mail: tbwei@semi.ac.cn; Xiong, Zhuo; Chen, Yu; Zhen, Aigong; Shan, Liang; Zhao, Yun; Hu, Qiang; Li, Jinmin; Wang, Junxi [Semiconductor Lighting Technology Research and Development Center, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083 (China)

    2014-11-21

    In this study, the multiple-exposure nanosphere-lens lithography method utilizing the polystyrene nanospheres with focusing behavior is investigated and introduced to fabricate diverse photonic crystals (PCs) on indium tin oxide to enhance the optical output power of GaN-based light-emitting diode (LED). Simulated results indicate that the focused light intensity decreases with increasing tilted angle due to the shadow effect introduced by adjacent nanospheres. The fill factor of nanopattern is tunable by controlling tilted angles and exposure times. To attain quadruple PC without overlapping patterns, mathematical calculation model is used to define the optimum range of tilted angles. Angular emission patterns and three-dimensional finite-difference time domain simulated results indicate that the enhanced light extraction of PC LEDs results mainly from diffused scattering effects, and the diffraction effects of PC on light extracted efficiency increase with the increase of fill factor. Furthermore, it is confirmed that the multiple PC can extract more light from GaN into air than common PC with same period and fill factor.

  5. The effect of pipecol angles for the magnetic electron lens on the aberration coefficients

    International Nuclear Information System (INIS)

    Al-Khshab, A. M.; Al-Khshab, A. H.

    1997-01-01

    The symmetric mag etic objective lens of great importance for the electronic microscopes intended for hi g resolution. Such lens is determined, not only by its geometries structure and shape parameters, but also by the influence of the variation of the pole piece angles. the results show that the Objective lens having the pole piece angle of 55 a has a considerable effect on the electron optical Properties. When this pole piece is appropriately and highly saturated, the lens possesses low spherical and chromatic aberration coefficients. This hind of pole piece lens leads to more favourable design than other lenses. (authors). 14 refs., 7 figs.1 table

  6. Optics

    CERN Document Server

    Mathieu, Jean Paul

    1975-01-01

    Optics, Parts 1 and 2 covers electromagnetic optics and quantum optics. The first part of the book examines the various of the important properties common to all electromagnetic radiation. This part also studies electromagnetic waves; electromagnetic optics of transparent isotropic and anisotropic media; diffraction; and two-wave and multi-wave interference. The polarization states of light, the velocity of light, and the special theory of relativity are also examined in this part. The second part is devoted to quantum optics, specifically discussing the classical molecular theory of optical p

  7. Imaging quality evaluation method of pixel coupled electro-optical imaging system

    Science.gov (United States)

    He, Xu; Yuan, Li; Jin, Chunqi; Zhang, Xiaohui

    2017-09-01

    With advancements in high-resolution imaging optical fiber bundle fabrication technology, traditional photoelectric imaging system have become ;flexible; with greatly reduced volume and weight. However, traditional image quality evaluation models are limited by the coupling discrete sampling effect of fiber-optic image bundles and charge-coupled device (CCD) pixels. This limitation substantially complicates the design, optimization, assembly, and evaluation image quality of the coupled discrete sampling imaging system. Based on the transfer process of grayscale cosine distribution optical signal in the fiber-optic image bundle and CCD, a mathematical model of coupled modulation transfer function (coupled-MTF) is established. This model can be used as a basis for following studies on the convergence and periodically oscillating characteristics of the function. We also propose the concept of the average coupled-MTF, which is consistent with the definition of traditional MTF. Based on this concept, the relationships among core distance, core layer radius, and average coupled-MTF are investigated.

  8. Nanomechanical control of optical field and quality factor in photonic crystal structures

    Science.gov (United States)

    Cotrufo, Michele; Midolo, Leonardo; Zobenica, Žarko; Petruzzella, Maurangelo; van Otten, Frank W. M.; Fiore, Andrea

    2018-03-01

    Actively controlling the properties of localized optical modes is crucial for cavity quantum electrodynamics experiments. While several methods to tune the optical frequency have been demonstrated, the possibility of controlling the shape of the modes has scarcely been investigated. Yet an active manipulation of the mode pattern would allow direct control of the mode volume and the quality factor and therefore of the radiative processes. In this work, we propose and demonstrate a nano-optoelectromechanical device in which a mechanical displacement affects the spatial pattern of the electromagnetic field. The device is based on a double-membrane photonic crystal waveguide which, upon bending, creates a spatial modulation of the effective refractive index, resulting in an effective potential well or antiwell for the optical modes. The change in the field pattern drastically affects the optical losses: large modulations of the quality factors and dissipative coupling rates larger than 1 GHz/nm are predicted by calculations and confirmed by experiments. This concept opens new avenues in solid-state cavity quantum electrodynamics in which the field, instead of the frequency, is coupled to the mechanical motion.

  9. Effects of Temperature on Hybrid Lens Performance

    Science.gov (United States)

    Askins, Steve; Victoria, Marta; Herrero, Rebeca; Domínguez, César; Antón, Ignacio; Sala, Gabriel

    2011-12-01

    In hybrid Silicone-on-glass Fresnel lenses, an optical silicone is molded onto a glass substrate and forms the Fresnel structure. These lenses offer a cost effective solution as a primary optical element in point-focus concentrator photovoltaic modules, as well as performance advantages. However, these lenses have a high performance variation with temperature due both to the change in index of refraction of silicone as well as to deformations in the facets caused by coefficient of thermal expansion (CTE) mismatch. In this study we perform measurements of the light flux at the focal plane of a family of SOG lenses, varying temperature and lens-to-receiver distances. The effect of varying silicone cure temperature and the depth of the silicone between the lens and the glass substrate on temperature dependence was investigated. A preliminary computer model of this behavior is presented.

  10. Candidate gravitational microlensing events for future direct lens imaging

    Energy Technology Data Exchange (ETDEWEB)

    Henderson, C. B.; Gould, A.; Gaudi, B. S. [Department of Astronomy, The Ohio State University, 140 West 18th Avenue, Columbus, OH 43210 (United States); Park, H.; Han, C. [Department of Physics, Institute for Astrophysics, Chungbuk National University, Cheongju 371-763 (Korea, Republic of); Sumi, T.; Koshimoto, N. [Department of Earth and Space Science, Osaka University, Osaka 560-0043 (Japan); Udalski, A. [Warsaw University Observatory, Al. Ujazdowskie 4, 00-478 Warszawa (Poland); Tsapras, Y. [Las Cumbres Observatory Global Telescope Network, 6740 Cortona Drive, Suite 102, Goleta, CA 93117 (United States); Bozza, V. [Department of Physics, University of Salerno, I-84084 Fisciano (Italy); Abe, F.; Fukunaga, D.; Itow, Y.; Masuda, K. [Solar-Terrestrial Environment Laboratory, Nagoya University, Nagoya 464-8601 (Japan); Bennett, D. P. [Department of Physics, University of Notre Dame, 225 Nieuwland Science Hall, Notre Dame, IN 46556-5670 (United States); Bond, I. A.; Ling, C. H. [Institute of Information and Mathematical Sciences, Massey University, Private Bag 102-904, North Shore Mail Centre, Auckland 0745 (New Zealand); Botzler, C. S.; Freeman, M. [Department of Physics, University of Auckland, Private Bag 92-019, Auckland 1001 (New Zealand); Fukui, A. [School of Chemical and Physical Sciences, Victoria University, Wellington 6140 (New Zealand); Collaboration: MOA Collaboration; OGLE Collaboration; μFUN Collaboration; RoboNet Collaboration; and others

    2014-10-10

    The mass of the lenses giving rise to Galactic microlensing events can be constrained by measuring the relative lens-source proper motion and lens flux. The flux of the lens can be separated from that of the source, companions to the source, and unrelated nearby stars with high-resolution images taken when the lens and source are spatially resolved. For typical ground-based adaptive optics (AO) or space-based observations, this requires either inordinately long time baselines or high relative proper motions. We provide a list of microlensing events toward the Galactic bulge with high relative lens-source proper motion that are therefore good candidates for constraining the lens mass with future high-resolution imaging. We investigate all events from 2004 to 2013 that display detectable finite-source effects, a feature that allows us to measure the proper motion. In total, we present 20 events with μ ≳ 8 mas yr{sup –1}. Of these, 14 were culled from previous analyses while 6 are new, including OGLE-2004-BLG-368, MOA-2005-BLG-36, OGLE-2012-BLG-0211, OGLE-2012-BLG-0456, MOA-2012-BLG-532, and MOA-2013-BLG-029. In ≲12 yr from the time of each event the lens and source of each event will be sufficiently separated for ground-based telescopes with AO systems or space telescopes to resolve each component and further characterize the lens system. Furthermore, for the most recent events, comparison of the lens flux estimates from images taken immediately to those estimated from images taken when the lens and source are resolved can be used to empirically check the robustness of the single-epoch method currently being used to estimate lens masses for many events.

  11. How histological features of basal cell carcinomas influence image quality in optical coherence tomography

    DEFF Research Database (Denmark)

    Mogensen, Mette; Nürnberg, Birgit M.; Thrane, Lars

    2011-01-01

    Optical coherence tomography (OCT) has the potential to diagnose and measure the depth of nonmelanoma skin cancer (NMSC) in skin, but some lesions appear blurred in OCT images. The aim of this study is to identify histological characteristics of basal cell carcinomas (BCC) that correlate with good...... quality OCT images of the same lesions. A total of 34 patients with BCC were OCT scanned. The influence of histology parameters (e.g. inflammation, sun damage of skin, carcinoma cell size) on OCT image quality was studied by comparing 15 BCC lesions easily identified compared to 19 BCC lesions...

  12. Estimation of fringe orientation for optical fringe patterns with poor quality based on Fourier transform.

    Science.gov (United States)

    Tang, Chen; Wang, Zhifang; Wang, Linlin; Wu, Jian; Gao, Tao; Yan, Si

    2010-02-01

    Fringe orientation represents an important property of fringes. The estimation of orientation from a poor quality fringe image is still a challenging problem faced in this area. This paper introduces a new approach for estimating optical fringe orientation with a poor quality image. This approach is based on the power spectrum analysis of the Fourier transform. We evaluate the performance of this algorithm via application to a variety of test cases and comparison with the widely used gradient-based method and accumulate-differences method. The experimental results show that our method is capable of calculating fringe orientation robustly even when the quality of fringe images is considerably low because of high or low density, high noise, and low contrast. Under the same conditions, our accuracy is even better than that obtained with the gradient-based and accumulate-differences methods, especially for fringe images with poor quality.

  13. Characteristic of laser diode beam propagation through a collimating lens.

    Science.gov (United States)

    Xu, Qiang; Han, Yiping; Cui, Zhiwei

    2010-01-20

    A mathematical model of a laser diode beam propagating through a collimating lens is presented. Wave propagation beyond the paraxial approximation is studied. The phase delay of the laser diode wave in passing through the lens is analyzed in detail. The propagation optical field after the lens is obtained from the diffraction integral by the stationary phase method. The model is employed to predict the light intensity at various beam cross sections, and the computed intensity distributions are in a good agreement with the corresponding measurements.

  14. Aspherical lens design using hybrid neural-genetic algorithm of contact lenses.

    Science.gov (United States)

    Yen, Chih-Ta; Ye, Jhe-Wen

    2015-10-01

    The design of complex contact lenses involves numerous uncertain variables. How to help an optical designer to first design the optimal contact lens to reduce discomfort when wearing a pair of glasses is an essential design concern. This study examined the impact of aberrations on contact lenses to optimize a contact lens design for myopic and astigmatic eyes. In general, two aspherical surfaces can be assembled in an optical system to reduce the overall volume size. However, this design reduces the spherical aberration (SA) values at wide contact radii. The proposed optimization algorithm with optical design can be corrected to improve the SA value and, thus, reduce coma aberration (TCO) values and enhance the modulation transfer function (MTF). This means integrating a modified genetic algorithm (GA) with a neural network (NN) to optimize multiple-quality characteristics, namely the SA, TCO, and MTF, of contact lenses. When the proposed optional weight NN-GA is implemented, the weight values of the fitness function can be varied to adjust system performance. The method simplifies the selection of parameters in the optimization of optical systems. Compared with the traditional CODE V built-in optimal scheme, the proposed scheme is more flexible and intuitive to improve SA, TCO, and MTF values by 50.03%, 45.78%, and 24.7%, respectively.

  15. Analysis and synthesis of supershaped dielectric lens antennas

    OpenAIRE

    Bia, Pietro; Caratelli, Diego; Mescia, Luciano; Gielis, Johan

    2015-01-01

    Abstract: A novel class of supershaped dielectric lens antennas, whose geometry is described by the three-dimensional (3D) Gielis formula, is introduced and analysed. To this end, a hybrid modelling approach based on geometrical and physical optics is adopted in order to efficiently analyse the multiple wave reflections occurring within the lens and to evaluate the relevant impact on the radiation properties of the antenna under analysis. The developed modelling procedure has been validated b...

  16. Signal-enhancement reflective pulse oximeter with Fresnel lens

    Science.gov (United States)

    Chung, Shuang-Chao; Sun, Ching-Cherng

    2016-09-01

    In this paper, a new reflective pulse oximeter is proposed and demonstrated with implanting a Fresnel lens, which enhances the reflected signal. An optical simulation model incorporated with human skin characteristics is presented to evaluate the capability of the Fresnel lens. In addition, the distance between the light emitting diode and the photodiode is optimized. Compared with the other reflective oximeters, the reflected signal light detected by the photodiode is enhanced to more than 140%.

  17. Photonic crystal based polarization insensitive flat lens

    Science.gov (United States)

    Turduev, M.; Bor, E.; Kurt, H.

    2017-07-01

    The paper proposes a new design of an inhomogeneous artificially created photonic crystal lens structure consisting of annular dielectric rods to efficiently focus both transverse electric and transverse magnetic polarizations of light into the same focal point. The locations of each individual cell that contains the annular dielectric rods are determined according to a nonlinear distribution function. The inner and outer radii of the annular photonic dielectric rods are optimized with respect to the polarization insensitive frequency response of the transmission spectrum of the lens structure. The physical background of the polarization insensitive focusing mechanism is investigated in both spatial and frequency domains. Moreover, polarization independent wavefront transformation/focusing has been explored in detail by investigating the dispersion relation of the structure. Corresponding phase index distribution of the lens is attained for polarization insensitive normalized frequency range of a/λ  =  0.280 and a/λ  =  0.300, where a denotes the lattice constant of the designed structure and λ denotes the wavelength of the incident light. We show the wave transformation performance and focal point movement dynamics for both polarizations of the lens structure by specially adjusting the length of the structure. The 3D finite-difference time domain numerical analysis is also performed to verifiy that the proposed design is able to focus the wave regardless of polarization into approximately the same focal point (difference between focal distances of both polarizations stays below 0.25λ) with an operating bandwidth of 4.30% between 1476 nm and 1541 nm at telecom wavelengths. The main superiorities of the proposed lens structure are being all dielectric and compact, and having flat front and back surfaces, rendering the proposed lens design more practical in the photonic integration process in various applications such as optical switch

  18. The correct lens mount lightweighting design of thermal cycle stress in Cassegrain telescope

    Science.gov (United States)

    Hsu, M. Y.; Chang, S. T.; Huang, T. M.; Hsu, Ming-Ying

    2011-10-01

    The Cassegrain telescope system was design for space environment. The correct lens mount assembly is included as correct lens, lens mount, spacer, mount barrel and retainer. The system mass budget allocated to correct lens assembly was 5 Kg. Meanwhile, according to optical design the correct lens is made from fused silica, the lens diameter is 130 mm, and the mass is 2.3 Kg. Therefore, remain mass budget is 2.7 Kg; including the lens mount, spacer, mount barrel and retainer. The telescope system deformation is mainly caused by thermal deformation on space orbit. The correct lens mount was made from invar material in initial design. The CTE (Coefficient of Thermal Expansion) of invar is only 1* 10-6/°C, low CTE would be resistant to thermal deformation, but invar density is 8* 10-6 kg/mm3. If all components were made from invar, the total mass was over 2.7 kg. Thus, the components material would consider titanium alloy (CTE is 8.6* 10-6/°C, density is 4.43* 10-6 kg/mm3) or aluminum alloy (CTE is 23.6* 10-6/°C, density is 2.81* 10-6 kg/mm3). The titanium alloy density is 1.83 times lighter than invar, but CTE is 8.6 times higher. The aluminum alloy density is 2.84 times lighter then invar, but CTE is 23.6 times higher. The lens mount thermal deformation would effect correct lens surface wavefront error and introduce optical aberration. This article analyzes the correct lens assembly thermal deformation and optical performance in different lens mount material. From above conditions, using FEM (Finite Element Method) and optical software, simulation and optimization on the lens mount design have been performed to achieve system mass requirement.

  19. Design and analysis of an adaptive lens that mimics the performance of the crystalline lens in the human eye

    Science.gov (United States)

    Santiago-Alvarado, Agustin; Cruz-Félix, Angel S.; Iturbide-Jiménez, F.; Martínez-López, M.; Ramírez-Como, M.; Armengol-Cruz, V.; Vásquez-Báez, I.

    2014-09-01

    Tunable lenses are optical systems that have attracted much attention due to their potential applications in such areas like ophthalmology, machine vision, microscopy and laser processing. In recent years we have been working in the analysis and performance of a liquid-filled variable focal length lens, this is a lens that can modify its focal length by changing the amount of water within it. Nowadays we extend our study to a particular adaptive lens known as solid elastic lens (SEL) that it is formed by an elastic main body made of Polydimethylsiloxane (PDMS Sylgard 184). In this work, we present the design, simulation and analysis of an adaptive solid elastic lens that in principle imitates the accommodation process of the crystalline lens in the human eye. For this work, we have adopted the parameters of the schematic eye model developed in 1985 by Navarro et al.; this model represents the anatomy of the eye as close as possible to reality by predicting an acceptable and accurate quantity of spherical and chromatic aberrations without any shape fitting. An opto-mechanical analysis of the accommodation process of the adaptive lens is presented, by simulating a certain amount of radial force applied onto the SEL using the finite element method with the commercial software SolidWorks®. We also present ray-trace diagrams of the simulated compression process of the adaptive lens using the commercial software OSLO®.

  20. Joint influences of aerodynamic flow field and aerodynamic heating of the dome on imaging quality degradation of airborne optical systems.

    Science.gov (United States)

    Xiao, Haosu; Zuo, Baojun; Tian, Yi; Zhang, Wang; Hao, Chenglong; Liu, Chaofeng; Li, Qi; Li, Fan; Zhang, Li; Fan, Zhigang

    2012-12-20

    We investigated the joint influences exerted by the nonuniform aerodynamic flow field surrounding the optical dome and the aerodynamic heating of the dome on imaging quality degradation of an airborne optical system. The Spalart-Allmaras model provided by FLUENT was used for flow computations. The fourth-order Runge-Kutta algorithm based ray tracing program was used to simulate optical transmission through the aerodynamic flow field and the dome. Four kinds of imaging quality evaluation parameters were presented: wave aberration of the exit pupil, point spread function, encircled energy, and modulation transfer function. The results show that the aero-optical disturbance of the aerodynamic flow field and the aerodynamic heating of the dome significantly affect the imaging quality of an airborne optical system.

  1. Remotely Sensed Optical Water Quality for Water Quality Assessment and Seagrass Protection in Florida's Big Bend Region

    Science.gov (United States)

    Carlson, P. R.; Hu, C.; Cannizarro, J.; Yarbro, L. A.; English, D. C.; Magley, W.; Charbonneau, M.; Barnes, B.

    2012-12-01

    Florida's Big Bend coastal region contains the second largest contiguous seagrass bed in the continental US. Approximately 250,000 ha of seagrass have been mapped in the region, but the total area of offshore seagrass beds might be several times greater. The Suwannee River drains a largely agricultural watershed (26,000 km2) in Georgia and Florida, and its discharge (x= 280 m3/s) affects water clarity over most of the Big Bend seagrass beds. Seagrass density, species composition and areal extent were severely affected by discharge associated with tropical cyclones in 2004 and 2005, focusing attention on this important resource and the near- and far-field impacts of the Suwannee River discharge. The Lower Suwannee River also has been identified by the Florida Department of Environmental Protection as an impaired water body due to high nitrogen and algal biomass. This project attempts to improve water quality and to protect Big Bend seagrasses by making remotely sensed optical water quality data more accessible to managers and stakeholders involved in the process of regulating nutrient loads in the Suwannee River and to provide data to assess effectiveness of management actions. To accomplish these goals, we have developed and tested new algorithms for retrieval of Kd, chlorophyll, and CDOM from Modis imagery, created a time series of optical water quality (OWQ) for the Suwannee River Estuary (SRE), and related seagrass gains and losses to annual variations in optical water quality. During two years of bimonthly ground-truth cruises, chlorophyll concentrations, Aph, Ad, and Acdom in the SRE were 0.3-38.3 mgm-3, 0.013-1.056, 0.013-0.735, and 0.042-7.24, respectively. For most locations and most cruises, CDOM was the dominant determinant of Kd. In the Modis time series, Kd488 estimates (calculated using the Quasi-Analytic Algorithm of Lee et al. 2006) covaried with Suwannee River discharge between 2002 and 2011 with an overall r2 value of 0.64. This relationship is

  2. Suitability of Optical, Physical and Chemical Measurements for Detection of Changes in Bacterial Drinking Water Quality

    Science.gov (United States)

    Ikonen, Jenni; Pitkänen, Tarja; Miettinen, Ilkka T.

    2013-01-01

    In this study, different optical, physical and chemical measurements were tested for their capacity to detect changes in water quality. The tests included UV-absorbance at 254 nm, absorbance at 420 nm, turbidity, particle counting, temperature, pH, electric conductivity (EC), free chlorine concentration and ATP concentration measurements. Special emphasis was given to investigating the potential for measurement tools to detect changes in bacterial concentrations in drinking water. Bacterial colony counts (CFU) and total bacterial cell counts (TBC) were used as reference methods for assessing the bacterial water quality. The study consists of a series of laboratory scale experiments: monitoring of regrowth of Pseudomonas fluorescens, estimation of the detection limits for optical measurements using Escherichia coli dilutions, verification of the relationships by analysing grab water samples from various distribution systems and utilisation of the measurements in the case of an accidentally contaminated distribution network. We found significant correlations between the tested measurements and the bacterial water quality. As the bacterial contamination of water often co-occurs with the intrusion of matrixes containing mainly non-bacterial components, the tested measurement tools can be considered to have the potential to rapidly detect any major changes in drinking water quality. PMID:24284353

  3. Composição e qualidade de pólen apícola coletado em Minas Gerais Nutritional composition and quality of bee pollen collected in Minas Gerais, Brazil

    Directory of Open Access Journals (Sweden)

    Anna Frida Hatsue Modro

    2007-08-01

    Full Text Available O objetivo deste trabalho foi avaliar a influência das composições florísticas locais sobre a qualidade do pólen apícola, em dois apiários de Minas Gerais. Em cada apiário, foram instaladas cinco colméias de Apis mellifera (L.. A flora polinífera foi identificada nas proximidades dos apiários. As bolotas de pólen foram coletadas de agosto a dezembro de 2005. A análise melissopalinológica foi realizada pelo método padrão europeu. Foram realizadas análises nutricionais do pólen relativas à porcentagem de matéria seca, orgânica e mineral, à proteína bruta, ao extrato etéreo e aos carboidratos totais. Foi realizada correlação de Spearman entre os componentes nutricionais e os tipos polínicos ocorrentes. No apiário UFV, a flora polinífera predominante apresentou espécies ornamentais com hábito arbóreo, e no apiário Mesmel predominaram as espécies da pastagem abandonada com hábito herbáceo. A composição nutricional do pólen coletado não apresentou correlação com a diversidade de tipos polínicos, mas apresentou correlação com a predominância de tipos polínicos específicos. As diferentes composições florísticas influenciam na qualidade do pólen apícola, e a coleta em diversas fontes de alimento, pelas abelhas, é importante para a obtenção de uma dieta mais equilibrada.The objective of this work was to assess the influence of the local floral composition on the quality of apicultural pollen collected in two apiaries, in Minas Gerais State, Brazil. Five hives of Apis mellifera (L. were installed in each apiary. The polliniferous flora in the proximity of the apiaries was identified. The pollen loads were collected from August to December, 2005. The melissopalinological analysis was carried out following the standard European method. Nutritional analyses of pollen were performed related to percentages of dry, organic and mineral matter; to raw protein; to ether extract; and to total carbohydrates

  4. High Quality, Low-Scatter SiC Optics Suitable for Space-based UV & EUV Applications, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — SSG Precision Optronics proposes the development and demonstration of a new optical fabrication process for the production of EUV quality Silicon Carbide (SiC)...

  5. Production and quality control of optical elements for the end cap hadron calorimeter of the CMS setup

    CERN Document Server

    Abramov, V V; Korablev, A V; Korneev, Yu P; Krinitsyn, A N; Kryshkin, V I; Markov, A A; Talov, VV; Turchanovich, L K; Volkov, A A; Zaichenko, A A

    2005-01-01

    An end cap hadron calorimeter, in which scintillators with wavelength-shifting fibers are used as the active elements, has been designed for the compact muon spectrometer (CMS) now under construction at CERN. A total of 1368 optical elements containing 21 096 scintillators have already been manufactured. The production and quality control procedures for these optical elements are described. copy 2005 Pleiades Publishing, Inc.

  6. A catoptric lens

    International Nuclear Information System (INIS)

    Rambauske, W.R.

    1973-01-01

    The invention relates to a catoptric lens for combining energies transmitted by several sources such as lasers; said lens comprising mirrors, the reflective surfaces of which have their focuses spaced from a common axis of symmetry. By means of these reflecting surfaces, which are generated by the nutation of portions of quadratic conics about the axis of symmetry, it is possible to focus the energy emmited by several lasers at the focus of the exit-mirror reflecting surface. This can be applied to thermonuclear fusion [fr

  7. Creation of sophisticated test objects for quality assurance of optical computed tomography scanners

    Energy Technology Data Exchange (ETDEWEB)

    Rahman, A T Abdul; Braeuer-Krisch, Elke; Brochard, Thierry; Adamovics, John; Clowes, Steve; Bradley, David; Doran, Simon, E-mail: Simon.Doran@icr.ac.u

    2010-11-01

    Optical computed tomography (CT) shows great potential for radiation therapy dose verification in 3D. However, an effective quality assurance regime for the various scanners currently available still remains to be developed. We show how the favourable properties of the PRESAGE{sup TM} radiochromic polymer may be exploited to create highly sophisticated QA phantoms. Five 60 mm-diameter cylindrical PRESAGE{sup TM} samples were irradiated using the x-ray microbeam radiation therapy facility on the ID17 biomedical beamline at the European Synchrotron Radiation Facility. Samples were then imaged on the University of Surrey parallel-beam optical CT scanner and were designed to allow a variety of tests to be performed, including linearity, MTF (three independent measurements) and an assessment of geometric distortion. A small sample of these results is presented. It is clear that, although the method produces extremely high quality test objects, it is not practical on a routine basis, because of its reliance of a highly specialised radiation source. Hence, we investigated a second possibility. Two PRESAGE{sup TM} samples were illuminated with ultraviolet light of wavelength 365 nm, using cheap masks created by laser-printing patterns onto overhead projector acetate sheets. There was good correlation between optical density (OD) measured by the CT scanner and the expected UV 'dose' delivered. The results are highly encouraging and a proposal is made for a scanner test regime based on calibrated and well characterised PRESAGE{sup TM} samples.

  8. Development of a multi-analyte integrated optical sensor platform for indoor air-quality monitoring

    Science.gov (United States)

    McGaughey, Orla; Nooney, Robert; McEvoy, Aisling K.; McDonagh, Colette; MacCraith, Brian D.

    2005-11-01

    The major trends driving optical chemical sensor technology are miniaturisation and multi-parameter functionality on a single platform (so-called multi-analyte sensing). A multi-analyte sensor chip device based on miniature waveguide structures, porous sensor materials and compact optoelectronic components has been developed. One of the major challenges in fluorescence-based optical sensor design is the efficient capture of emitted fluorescence from a fluorophore and the effective detection of the signal. In this work, the sensor platform has been fabricated using poly(methyl methacrylate), PMMA, as the waveguide material. These platforms employ a novel optical configuration along with rapid prototyping technology, which facilitates the production of an effective sensor platform. Sensing films for oxygen, carbon dioxide and humidity have been developed. These films consist of a fluorescent indicator dye entrapped in a porous immobilisation matrix. The analyte diffuses through the porous matrix and reacts with the indicator dye, causing changes in the detected fluorescence. The reaction between the dye and the analyte is completely reversible with no degradation of the signal after detection of different concentrations of the analyte. A single LED excitation source is used for all three analytes, and the sensor platform is housed in a compact unit containing the excitation source, filters and detector. The simultaneous detection of several analytes is a major requirement for fields such as food packaging, environmental quality control and biomedical diagnostics. The current sensor chip is designed for use in indoor air-quality monitoring.

  9. Optical biosensors for food quality and safety assurance-a review.

    Science.gov (United States)

    Narsaiah, K; Jha, Shyam Narayan; Bhardwaj, Rishi; Sharma, Rajiv; Kumar, Ramesh

    2012-08-01

    Food quality and safety is a scientific discipline describing handling, preparation and storage of food in ways that prevent food borne illness. Food serves as a growth medium for microorganisms that can be pathogenic or cause food spoilage. Therefore, it is imperative to have stringent laws and standards for the preparation, packaging and transportation of food. The conventional methods for detection of food contamination based on culturing, colony counting, chromatography and immunoassay are tedious and time consuming while biosensors have overcome some of these disadvantages. There is growing interest in biosensors due to high specificity, convenience and quick response. Optical biosensors show greater potential for the detection of pathogens, pesticide and drug residues, hygiene monitoring, heavy metals and other toxic substances in the food to check whether it is safe for consumption or not. This review focuses on optical biosensors, the recent developments in the associated instrumentation with emphasis on fiber optic and surface plasmon resonance (SPR) based biosensors for detecting a range of analytes in food samples, the major advantages and challenges associated with optical biosensors. It also briefly covers the different methods employed for the immobilization of bio-molecules used in developing biosensors.

  10. Miniaturized high-resolution wide-field contact lens for panretinal photocoagulation

    Directory of Open Access Journals (Sweden)

    Koushan K

    2014-04-01

    Full Text Available Keyvan Koushan, KV Chalam Department of Ophthalmology, University of Florida College of Medicine, Jacksonville, FL, USA Background and objective: We describe a miniaturized lightweight high-refractive-index panretinal contact lens for diagnostic and therapeutic visualization of the peripheral retina. Instrument design: The miniaturized high-resolution wide-field contact lens includes three optical elements in a light (15 g and miniaturized (16 mm footplate, 24 mm external aperture, and 21 mm vertical height casing contributing to a total dioptric power of +171 diopters. This lens provides up to 165° visualization of the retina for diagnostic and therapeutic applications while allowing easier placement due to its miniaturization. Conclusion: This new lens (50% lighter and 89% smaller improves upon earlier contact lenses for visualization of the peripheral retina. Keywords: contact lens, panretinal photocoagulation, retinal examination, peripheral retina, high resolution view, wide-angle lens, lens

  11. Qualification of a Null Lens Using Image-Based Phase Retrieval

    Science.gov (United States)

    Bolcar, Matthew R.; Aronstein, David L.; Hill, Peter C.; Smith, J. Scott; Zielinski, Thomas P.

    2012-01-01

    In measuring the figure error of an aspheric optic using a null lens, the wavefront contribution from the null lens must be independently and accurately characterized in order to isolate the optical performance of the aspheric optic alone. Various techniques can be used to characterize such a null lens, including interferometry, profilometry and image-based methods. Only image-based methods, such as phase retrieval, can measure the null-lens wavefront in situ - in single-pass, and at the same conjugates and in the same alignment state in which the null lens will ultimately be used - with no additional optical components. Due to the intended purpose of a Dull lens (e.g., to null a large aspheric wavefront with a near-equal-but-opposite spherical wavefront), characterizing a null-lens wavefront presents several challenges to image-based phase retrieval: Large wavefront slopes and high-dynamic-range data decrease the capture range of phase-retrieval algorithms, increase the requirements on the fidelity of the forward model of the optical system, and make it difficult to extract diagnostic information (e.g., the system F/#) from the image data. In this paper, we present a study of these effects on phase-retrieval algorithms in the context of a null lens used in component development for the Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission. Approaches for mitigation are also discussed.

  12. Use of focus measure operators for characterization of flood illumination adaptive optics ophthalmoscopy image quality.

    Science.gov (United States)

    Alonso-Caneiro, David; Sampson, Danuta M; Chew, Avenell L; Collins, Michael J; Chen, Fred K

    2018-02-01

    Adaptive optics flood illumination ophthalmoscopy (AO-FIO) allows imaging of the cone photoreceptor in the living human retina. However, clinical interpretation of the AO-FIO image remains challenging due to suboptimal quality arising from residual uncorrected wavefront aberrations and rapid eye motion. An objective method of assessing image quality is necessary to determine whether an AO-FIO image is suitable for grading and diagnostic purpose. In this work, we explore the use of focus measure operators as a surrogate measure of AO-FIO image quality. A set of operators are tested on data sets acquired at different focal depths and different retinal locations from healthy volunteers. Our results demonstrate differences in focus measure operator performance in quantifying AO-FIO image quality. Further, we discuss the potential application of the selected focus operators in (i) selection of the best quality AO-FIO image from a series of images collected at the same retinal location and (ii) assessment of longitudinal changes in the diseased retina. Focus function could be incorporated into real-time AO-FIO image processing and provide an initial automated quality assessment during image acquisition or reading center grading.

  13. Flexible optical metrology strategies for the control and quality assurance of small series production

    Science.gov (United States)

    Schmitt, R.; Pavim, A.

    2009-06-01

    The demand for achieving smaller and more flexible production series with a considerable diversity of products complicates the control of the manufacturing tasks, leading to big challenges for the quality assurance systems. The quality assurance strategy that is nowadays used for mass production is unable to cope with the inspection flexibility needed among automated small series production, because the measuring strategy is totally dependent on the fixed features of the few manufactured object variants and on process parameters that can be controlled/compensated during production time. The major challenge faced by a quality assurance system applied to small series production facilities is to guarantee the needed quality level already at the first run, and therefore, the quality assurance system has to adapt itself constantly to the new manufacturing conditions. The small series production culture requires a change of paradigms, because its strategies are totally different from mass production. This work discusses the tight inspection requirements of small series production and presents flexible metrology strategies based on optical sensor data fusion techniques, agent-based systems as well as cognitive and self-optimised systems for assuring the needed quality level of flexible small series. Examples of application scenarios are provided among the automated assembly of solid state lasers and the flexible inspection of automotive headlights.

  14. Use of focus measure operators for characterization of flood illumination adaptive optics ophthalmoscopy image quality

    Science.gov (United States)

    Alonso-Caneiro, David; Sampson, Danuta M.; Chew, Avenell L.; Collins, Michael J.; Chen, Fred K.

    2018-01-01

    Adaptive optics flood illumination ophthalmoscopy (AO-FIO) allows imaging of the cone photoreceptor in the living human retina. However, clinical interpretation of the AO-FIO image remains challenging due to suboptimal quality arising from residual uncorrected wavefront aberrations and rapid eye motion. An objective method of assessing image quality is necessary to determine whether an AO-FIO image is suitable for grading and diagnostic purpose. In this work, we explore the use of focus measure operators as a surrogate measure of AO-FIO image quality. A set of operators are tested on data sets acquired at different focal depths and different retinal locations from healthy volunteers. Our results demonstrate differences in focus measure operator performance in quantifying AO-FIO image quality. Further, we discuss the potential application of the selected focus operators in (i) selection of the best quality AO-FIO image from a series of images collected at the same retinal location and (ii) assessment of longitudinal changes in the diseased retina. Focus function could be incorporated into real-time AO-FIO image processing and provide an initial automated quality assessment during image acquisition or reading center grading. PMID:29552404

  15. In situ optical water-quality sensor networks - Workshop summary report

    Science.gov (United States)

    Pellerin, Brian A.; Bergamaschi, Brian A.; Horsburgh, Jeffery S.

    2012-01-01

    Advanced in situ optical water-quality sensors and new techniques for data analysis hold enormous promise for furthering scientific understanding of aquatic systems. These sensors measure important biogeochemical parameters for long deployments, enabling the capture of data at time scales over which they vary most meaningfully. The high-frequency, real-time water-quality data they generate provide opportunities for early warning of water-quality deterioration, trend detection, and science-based decision support. However, developing networks of optical sensors in freshwater systems that report reliable and comparable data across and between sites remains a challenge to the research and monitoring community. To address this, the U. S. Geological Survey (USGS) and the Consortium of Universities for the Advancement of Hydrologic Science, Inc. (CUAHSI) convened a joint 3-day workshop (June 8-10, 2011) at the National Conservation Training Center in Shepardstown, West Virginia, to explore ways to coordinate development of standards and applications for optical sensors, and improve handling, storing, and analyzing the continuous data they produce. The workshop brought together more than 60 scientists, program managers, and vendors from universities, government agencies, and the private sector. Several important outcomes emerged from the presentations and breakout sessions. There was general consensus that making intercalibrated measurements requires that both manufacturers and users better characterize and calibrate the sensors under field conditions. For example, the influence of suspended particles, highly colored water, and temperature on optical sensors remains poorly understood, but consistently accounting for these factors is critical to successful deployment and for interpreting results in different settings. This, in turn, highlights the lack of appropriate standards for sensor calibrations, field checks, and characterizing interferences, as well as methods for

  16. Multi-parameter measurements using optical fibre long period gratings for indoor air quality monitoring

    Science.gov (United States)

    Hromadka, J.; Korposh, S.; Partridge, M. C.; James, S.; Davis, F.; Crump, D.; Lee, S.-W.; Tatam, R. P.

    2017-04-01

    An array of three long period gratings (LPGs) fabricated in a single optical fibre and multiplexed in the wavelength domain was used to measure simultaneously temperature, relative humidity (RH) and volatile organic compounds (VOCs). Each LPG sensor was designed to optimize its response to a desired measurand. The LPGs were fabricated with periods such that they operated at or near the phase matching turning point. The sensors were calibrated in the laboratory and the simultaneous measurement of the key indoor air quality parameters was undertaken in laboratory and office environments. It was demonstrated successfully that the data produced by the LPG sensor array under real conditions was in a good agreement with that produced by commercially available sensors. Further, the potential application of fibre optic sensors for VOCs detection at high levels has been demonstrated.

  17. Electrically switchable holographic liquid crystal/polymer Fresnel lens using a Michelson interferometer.

    Science.gov (United States)

    Jashnsaz, Hossein; Mohajerani, Ezeddin; Nemati, Hossein; Razavi, Seyed Hossein; Alidokht, Isa Ahmad

    2011-06-10

    A holographic technique for fabricating an electrically switchable liquid crystal/polymer composite Fresnel lens is reported. A Michelson interferometer is used to produce the required Fresnel pattern, by placing a convex lens into one path of the interferometer. Simplicity of the method and the possibility of fabricating different focal length lenses in a single arrangement are advantages of the method. The performance of the fabricated lens was demonstrated and its electro-optical properties were investigated for its primary focal length.

  18. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... prescription. There is no such thing as a "one size fits all" contact lens. Lenses that are not properly fitted may scratch the eye or cause blood vessels to grow into the cornea. Even if you have perfect vision, you need to get an eye exam and a prescription ...

  19. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Ophthalmologist Patient Stories Español Eye Health / News Halloween Hazard: The Hidden Dangers of Buying Decorative Contact Lenses ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ...

  20. MISSING: BUBBLE CHAMBER LENS

    CERN Multimedia

    2001-01-01

    Would the person who borrowed the large bubble chamber lens from the Microcosm workshops on the ISR please return it. This is a much used piece from our object archives. If anybody has any information about the whereabouts of this object, please contact Emma.Sanders@cern.ch Thank you

  1. The Lens of Chemistry

    Science.gov (United States)

    Thalos, Mariam

    2013-01-01

    Chemistry possesses a distinctive theoretical lens--a distinctive set of theoretical concerns regarding the dynamics and transformations of a perplexing variety of organic and nonorganic substances--to which it must be faithful. Even if it is true that chemical facts bear a special (reductive) relationship to physical facts, nonetheless it will…

  2. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her with a corneal ... A recent article from U.S. News and World Report explains what ophthalmologists are and how they can ...

  3. bubble chamber lens

    CERN Multimedia

    Was used in a PS experiment. Before the days of electronic detectors, visual techniques were used to detect particles, using detectors such as spark chambers and bubble chambers. This plexiglass lens was used to focus the image of tracks so they could be photographed.

  4. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... an Ophthalmologist Patient Stories Español Eye Health / News Halloween Hazard: The Hidden Dangers of Buying Decorative Contact ... After One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter ...

  5. Time course of optical quality and intraocular scattering after refractive lenticule extraction.

    Directory of Open Access Journals (Sweden)

    Kazutaka Kamiya

    Full Text Available PURPOSE: To assess the time course of optical quality and intraocular scattering in relation to visual acuity after femtosecond lenticule extraction (FLEx for the correction of myopia. METHODS: This study evaluated 36 eyes of 36 patients with spherical equivalents of -4.38±1.53 D [mean ± standard deviation] who underwent FLEx. Before surgery, and 1 week and 1, 3 and 6 months after surgery, we assessed the modulation transfer function (MTF cutoff frequency, Strehl ratio, objective scattering index (OSI, and OQAS values (OVs, using a double-pass instrument. We also investigated the relationship of the OSI with corrected distance visual acuity (CDVA preoperatively and postoperatively. RESULTS: The mean changes in MTF cutoff frequency, Strehl ratio, OSI, OV100%, OV20%, and OV9% preoperatively and 6 months postoperatively were -5.51 ± 15.01, -0.03 ± 0.07, 0.35 ± 0.83, -0.17 ± 0.48, -0.14 ± 0.38, and -0.09 ± 0.22, respectively. We found no significant preoperative correlation between the OSI and logMAR CDVA (Spearman rank correlation coefficient r = 0.068, p = 0.69, and modest, but significant correlations 1 week and 1, 3, and 6 months postoperatively (r = 0.572, r = 0.562, r = 0.542, r = 0.540, p<0.001, respectively. CONCLUSIONS: FLEx induced a transient decrease in optical quality in association with an increase in intraocular scattering in the early postoperative period, possibly due to mild interface haze formation, but gradually recovered with time. It is suggested that this transient degradation in optical quality related to an increase in the intraocular scattering may result in a slight delay of CDVA recovery in the early postoperative period.

  6. Engineering Design, construction and testing of an optical device for ...

    African Journals Online (AJOL)

    This study reports the design, construction and testing of an optical device to determine the fertility of poultry egg at early age. The device consists of optical components such as condenser lens, objective lens, eyepiece lens and a source of light, all encased in a wooden frame. It has a total length of about 1m and produces ...

  7. Dynamic metasurface lens based on MEMS technology

    Directory of Open Access Journals (Sweden)

    Tapashree Roy

    2018-02-01

    Full Text Available In the recent years, metasurfaces, being flat and lightweight, have been designed to replace bulky optical components with various functions. We demonstrate a monolithic Micro-Electro-Mechanical System (MEMS integrated with a metasurface-based flat lens that focuses light in the mid-infrared spectrum. A two-dimensional scanning MEMS platform controls the angle of the lens along two orthogonal axes by ±9°, thus enabling dynamic beam steering. The device could be used to compensate for off-axis incident light and thus correct for aberrations such as coma. We show that for low angular displacements, the integrated lens-on-MEMS system does not affect the mechanical performance of the MEMS actuators and preserves the focused beam profile as well as the measured full width at half maximum. We envision a new class of flat optical devices with active control provided by the combination of metasurfaces and MEMS for a wide range of applications, such as miniaturized MEMS-based microscope systems, LIDAR scanners, and projection systems.

  8. Dynamic metasurface lens based on MEMS technology

    Science.gov (United States)

    Roy, Tapashree; Zhang, Shuyan; Jung, Il Woong; Troccoli, Mariano; Capasso, Federico; Lopez, Daniel

    2018-02-01

    In the recent years, metasurfaces, being flat and lightweight, have been designed to replace bulky optical components with various functions. We demonstrate a monolithic Micro-Electro-Mechanical System (MEMS) integrated with a metasurface-based flat lens that focuses light in the mid-infrared spectrum. A two-dimensional scanning MEMS platform controls the angle of the lens along two orthogonal axes by ±9°, thus enabling dynamic beam steering. The device could be used to compensate for off-axis incident light and thus correct for aberrations such as coma. We show that for low angular displacements, the integrated lens-on-MEMS system does not affect the mechanical performance of the MEMS actuators and preserves the focused beam profile as well as the measured full width at half maximum. We envision a new class of flat optical devices with active control provided by the combination of metasurfaces and MEMS for a wide range of applications, such as miniaturized MEMS-based microscope systems, LIDAR scanners, and projection systems.

  9. Growth of optical-quality anthracene crystals doped with dibenzoterrylene for controlled single photon production

    Energy Technology Data Exchange (ETDEWEB)

    Major, Kyle D., E-mail: kyle.major11@imperial.ac.uk; Lien, Yu-Hung; Polisseni, Claudio; Grandi, Samuele; Kho, Kiang Wei; Clark, Alex S.; Hwang, J.; Hinds, E. A., E-mail: ed.hinds@imperial.ac.uk [Centre for Cold Matter, Department of Physics, Blackett Laboratory, Imperial College London, Prince Consort Road, London SW7 2AZ (United Kingdom)

    2015-08-15

    Dibenzoterrylene (DBT) molecules within a crystalline anthracene matrix show promise as quantum emitters for controlled, single photon production. We present the design and construction of a chamber in which we reproducibly grow doped anthracene crystals of optical quality that are several mm across and a few μm thick. We demonstrate control of the DBT concentration over the range 6–300 parts per trillion and show that these DBT molecules are stable single-photon emitters. We interpret our data with a simple model that provides some information on the vapour pressure of DBT.

  10. Dimensional quality control of Ti-Ni dental file by optical coordinate metrology and computed tomography

    DEFF Research Database (Denmark)

    Yagüe-Fabra, J.A.; Tosello, Guido; Ontiveros, S.

    2014-01-01

    techniques. However, the establishment of CT systems traceability when measuring 3D complex geometries is still an open issue. In this work, to verify the quality of the CT dimensional measurements, the dental file has been measured both with a μCT system and an optical CMM (OCMM). The uncertainty...... of measurements performed with both technologies is assessed. The estimated uncertainty is eventually compared with the component’s calibration and tolerances to validate the measuring capability of the μCT system....

  11. Design of apochromatic lens with large field and high definition for machine vision.

    Science.gov (United States)

    Yang, Ao; Gao, Xingyu; Li, Mingfeng

    2016-08-01

    Precise machine vision detection for a large object at a finite working distance (WD) requires that the lens has a high resolution for a large field of view (FOV). In this case, the effect of a secondary spectrum on image quality is not negligible. According to the detection requirements, a high resolution apochromatic objective is designed and analyzed. The initial optical structure (IOS) is combined with three segments. Next, the secondary spectrum of the IOS is corrected by replacing glasses using the dispersion vector analysis method based on the Buchdahl dispersion equation. Other aberrations are optimized by the commercial optical design software ZEMAX by properly choosing the optimization function operands. The optimized optical structure (OOS) has an f-number (F/#) of 3.08, a FOV of φ60  mm, a WD of 240 mm, and a modulated transfer function (MTF) of all fields of more than 0.1 at 320  cycles/mm. The design requirements for a nonfluorite material apochromatic objective lens with a large field and high definition for machine vision detection have been achieved.

  12. Clinical survey of lens care in contact lens patients.

    Science.gov (United States)

    Ky, W; Scherick, K; Stenson, S

    1998-10-01

    Overall, contact lenses provide a safe and effective modality for vision correction. However, problems do occasionally arise. Up to 80% of contact lens complications can be traced to poor patient compliance with recommended lens care guidelines. We conducted a survey to evaluate the level of patient compliance in specific areas of lens care and maintenance and to assess patient knowledge of basic contact lens information. Patients were asked to complete an anonymous 15 question survey that focused on lens care--specifically the use of contact lens cleaners, methods of disinfection, enzyme treatments, use of rewetting drops, and the frequency of follow-up exams. In addition, the survey included six true/false questions relating to contact lens care and safety. There were a total of 103 participants in the study. Approximately 24% of patients stated they never cleaned their lenses prior to disinfection, and 5% used saline solutions as their primary mode of disinfection. A sizable portion of those surveyed (43% of soft lens wearers and 71% of rigid gas permeable lens wearers) either never used enzyme cleaners or used them less than once a month. Seventy percent of patients either never used rewetting drops or used them less than once a day. Twenty-nine percent of patients consulted their eye care professionals every 2 years and 6% less often than every two years. Six questions assessed patient knowledge of contact lens care safety. Of a possible six out of six correct answers, the mean number of correct responses was 3.74. A sizable proportion of contact lens wearers do not adequately adhere to recommended contact lens care, and many have an inadequate understanding of contact lens care guidelines. Therefore, it is important that practitioners place more emphasis on patient education at the time of initial contact lens fitting and reinforce such instruction during follow-up visits.

  13. Applications of optical sensors for high-frequency water-quality monitoring and research

    Science.gov (United States)

    Pellerin, Brian

    2015-01-01

    The recent commercial availability of in-situ optical sensors, together with new techniques for data collection and analysis, provides the opportunity to monitor a wide range of water-quality constituents over time scales during which environmental conditions actually change. Traditional approaches for data collection (daily to monthly discrete samples) are often limited by high sample collection, processing, and analytical costs, difficult site access, and logistical challenges, particularly for long-term sampling at a large number of sites. Optical sensors that continuously measure constituents in the environment by absorbance or fluorescence properties (Figure 1) have had a long history of use in oceanography for measuring highly resolved concentrations and fluxes of organic matter, nutrients, and algal material. However, much of the work using commercially-available optical sensors in rivers and streams has taken place in only the last few years. Figure 1. [NOT SHOWN] Optical sensor technology is now sufficiently developed to warrant broader application for research and monitoring in coastal and freshwater systems, and the United States Geological Survey (a U.S. science agency) is now using these sensors in a variety of research and monitoring programs to better understand water quality in-situ and in real-time. Examples are numerous and range from the applications of nitrate sensors for calculating loads to estuaries susceptible to hypoxia (Pellerin et al., 2014) to the use of fluorometers to estimate methymercury fluxes (Bergamaschi et al., 2011) and disinfection byproduct formation (Carpenter et al., 2013). Transmitting these data in real-time provides information that can be used for early trend detection, help identify monitoring gaps critical for water management, and provide science-based decision support across a range of issues related to water quality, freshwater ecosystems, and human health. Despite the value of these sensors, collecting data that

  14. Non-invasive bleaching of the human lens by femtosecond laser photolysis

    DEFF Research Database (Denmark)

    Kessel, L.; Eskildsen, Lars; Poel, Mike van der

    2010-01-01

    were susceptible to photobleaching by a non-invasive procedure and whether this would lead to optical rejuvenation of the lens. Methodology/Principal Findings: Nine human donor lenses were treated with an 800 nm infra-red femtosecond pulsed laser in a treatment zone measuring 1 x 1 x 0.52 mm. After...... laser treatment the age-induced yellow discoloration of the lens was markedly reduced and the transmission of light was increased corresponding to an optical rejuvenation of 3 to 7 years. Conclusions/Significance: The results demonstrate that the age-induced yellowing of the human lens can be bleached...... by a non-invasive procedure based on femtosecond laser photolysis. Cataract is a disease associated with old age. At the current technological stage, lens aging is delayed but with a treatment covering the entire lens volume complete optical rejuvenation is expected. Thus, femtosecond photolysis has...

  15. Influência da quantidade de pólen na produção e qualidade de sementes híbridas de abóbora Influence of pollen amount on production and quality of squash hybrid seeds

    Directory of Open Access Journals (Sweden)

    WM Nascimento

    2011-03-01

    Full Text Available A baixa produção de sementes híbridas de abóbora obtida em nossas condições deve-se provavelmente aos métodos de produção pouco eficientes. A quantidade de pólen transferido naturalmente ou artificialmente entre os parentais pode afetar não só a produção como também a qualidade das sementes híbridas. Neste estudo, utilizou-se a polinização manual, a qual constou de cinco tratamentos relacionados com a quantidade de pólen do progenitor masculino para polinizar uma única flor feminina: um quarto da quantidade de pólen de uma flor; metade da quantidade de pólen de uma flor; a quantidade de pólen de uma flor; a quantidade de pólen de duas flores, e a quantidade de pólen de quatro flores masculinas. O delineamento experimental adotado foi em blocos ao acaso, com três repetições e dezoito plantas por parcela. O aumento da quantidade de pólen aplicada aumentou a produção de sementes por fruto e consequentemente a produção de sementes por área. A qualidade fisiológica das sementes praticamente não foi afetada entre os tratamentos, embora foi observada uma menor germinação das sementes obtidas em frutos provenientes de flores polinizadas com 1/4 de pólen.The low production of squash hybrid seeds obtained in our conditions is probably due to the inefficient production methods. The amount of pollen transferred naturally or artificially between the two parents may affect not only the hybrid seed production but also the seed quality of squash. In this study, flowers were manually pollinated using five amounts of pollen to pollinate one female flower: 1/4 of pollen from one flower; half of the amount of pollen from one flower; pollen of one flower; pollen of two flowers and pollen of four flowers. The randomized complete block design was adopted, with three replications and eighteen plants per plot. The increasing pollen amount affected significantly seed yield per fruit and seed yield per area, but did not influence

  16. Time lens assisted photonic sampling extraction

    Science.gov (United States)

    Petrillo, Keith Gordon

    Telecommunication bandwidth demands have dramatically increased in recent years due to Internet based services like cloud computing and storage, large file sharing, and video streaming. Additionally, sensing systems such as wideband radar, magnetic imaging resonance systems, and complex modulation formats to handle large data transfer in telecommunications require high speed, high resolution analog-to-digital converters (ADCs) to interpret the data. Accurately processing and acquiring the information at next generation data rates from these systems has become challenging for electronic systems. The largest contributors to the electronic bottleneck are bandwidth and timing jitter which limit speed and reduce accuracy. Optical systems have shown to have at least three orders of magnitude increase in bandwidth capabilities and state of the art mode locked lasers have reduced timing jitters into thousands of attoseconds. Such features have encouraged processing signals without the use of electronics or using photonics to assist electronics. All optical signal processing has allowed the processing of telecommunication line rates up to 1.28 Tb/s and high resolution analog-to-digital converters in the 10s of gigahertz. The major drawback to these optical systems is the high cost of the components. The application of all optical processing techniques such as a time lens and chirped processing can greatly reduce bandwidth and cost requirements of optical serial to parallel converters and push photonically assisted ADCs into the 100s of gigahertz. In this dissertation, the building blocks to a high speed photonically assisted ADC are demonstrated, each providing benefits to its own respective application. A serial to parallel converter using a continuously operating time lens as an optical Fourier processor is demonstrated to fully convert a 160-Gb/s optical time division multiplexed signal to 16 10-Gb/s channels with error free operation. Using chirped processing, an

  17. Stretched Lens Array Photovoltaic Concentrator Technology Developed

    Science.gov (United States)

    Piszczor, Michael F., Jr.; O'Neill, Mark J.

    2004-01-01

    Solar arrays have been and continue to be the mainstay in providing power to nearly all commercial and government spacecraft. Light from the Sun is directly converted into electrical energy using solar cells. One way to reduce the cost of future space power systems is by minimizing the size and number of expensive solar cells by focusing the sunlight onto smaller cells using concentrator optics. The stretched lens array (SLA) is a unique concept that uses arched Fresnel lens concentrators to focus sunlight onto a line of high-efficiency solar cells located directly beneath. The SLA concept is based on the Solar Concentrator Array with Refractive Linear Element Technology (SCARLET) design that was used on NASA's New Millennium Deep Space 1 mission. The highly successful asteroid/comet rendezvous mission (1998 to 2001) demonstrated the performance and long-term durability of the SCARLET/SLA solar array design and set the foundation for further improvements to optimize its performance.

  18. Intraocular lens implantation in microphthalmic patients.

    Science.gov (United States)

    Sinskey, R M; Amin, P; Stoppel, J

    1992-09-01

    Microphthalmos is a developmental disorder of the eye consisting of a smaller than normal eye. This disorder can present as an isolated condition or associated with other systemic alterations. It is not uncommon for patients with microphthalmos to have congenital cataracts along with other ocular and systemic abnormalities. This paper reports the experience with 11 microphthalmic eyes of seven patients who had primary or secondary intraocular lens (IOL) implantation over a six-year period from 1985 to 1991. In all cases the IOL had a 13.5 mm or 14.0 mm overall diameter and a 6.0 mm or 6.5 mm optic. It was difficult to obtain documentation of objective visual improvement in many of these cases because of the associated nystagmus. However, all patients reported subjective improvements. These results suggest that with proper technique and lens selection microphthalmic patients should be considered for IOL implantation with relative safety and success.

  19. High-quality-factor planar optical cavities with laterally stopped, slowed, or reversed light.

    Science.gov (United States)

    Byrnes, Steven J; Khorasaninejad, Mohammadreza; Capasso, Federico

    2016-08-08

    In a planar optical cavity, the resonance frequencies increase as a function of in-plane wavevector according to a standard textbook formula. This has well-known consequences in many different areas of optics, from the shifts of etalon peaks at non-normal angles, to the properties of transverse modes in laser diodes, to the effective mass of microcavity photons, and so on. However, this standard formula is valid only when the reflection phase of each cavity mirror is approximately independent of angle. There is a certain type of mirror-a subwavelength dielectric grating near a guided mode resonance-with not only a strongly angle-dependent reflection phase, but also very high reflectance and low losses. Simulations show that by using such mirrors, high-quality-factor planar cavities can be designed that break all these textbook rules, leading to resonant modes that are slow, stopped or even backward-propagating in the in-plane direction. In particular, we demonstrate experimentally high-Q planar cavities whose resonance frequency is independent of in-plane wavevector-i.e., the resonant modes have zero in-plane group velocity, for one polarization but both in-plane directions. We discuss potential applications in various fields including lasers, quantum optics, and exciton-polariton condensation.

  20. Simplified optical fiber RGB system in evaluating intrinsic quality of Sala mango

    Science.gov (United States)

    Yahaya, Ommi Kalsom Mardziah; Jafri, Mohd. Zubir Mat; Aziz, Azlan Abdul; Omar, Ahmad Fairuz

    2015-06-01

    This study presents an alternative approach for the nondestructive assessment of fruit quality parameters with the use of a simplified optical fiber red-green-blue system (OF-RGB). The optical sensor system presented in this work is designed to rapidly measure the firmness, acidity, and soluble solid content of an intact Sala mango on the basis of color properties. The system consists of three light-emitting diodes with peak emission at 635 (red), 525 (green), and 470 nm (blue), as well as a single photodetector capable of sensing visible light. The measurements were conducted using the reflectance technique. The analyses were conducted by comparing the results obtained through the proposed system with those measured using two commercial spectrometers, namely, QE65000 and FieldSpec 3. The developed RGB system showed satisfactory accuracy in the measurement of acidity (R2=0.795) and firmness (R2=0.761), but a relatively lower accuracy in the measurement of soluble solid content (R2=0.593) of intact mangoes. The results obtained through OF-RGB are comparable with those measured by QE65000 and FieldSpec 3. This system is a promising new technology with rapid response, easy operation, and low cost with potential applications in the nondestructive assessment of quality attributes.

  1. Four corneal presbyopia corrections: simulations of optical consequences on retinal image quality.

    Science.gov (United States)

    Koller, Tobias; Seiler, Theo

    2006-12-01

    To investigate the possibility of multifocal or aspherical treatment of the cornea with optical ray tracing. Institute for Refractive and Ophthalmic Surgery, Zurich, Switzerland. The optical consequences of 4 corneal shapes-global optimum (GO) for curvature and asphericity, central steep island (CSI), decentered steep island (DSI), and centered steep annulus (CSA)-for presbyopia correction were analyzed using a modified Liou-Brennan eye model and ray tracing with a commercial optic design software (Zemax, Zemax Development Corp.). The ocular optical configuration for far vision was a point light source at a distance of 5 m, 1 degree up, and a pupil diameter of 5.0 mm and for near vision, 0.4 m distance, 1 degree up, and a pupil diameter of 2.5 mm. The curvature radius (R) of the cornea and its asphericity (Q) were used as operands to optimize (simultaneously for near and far vision) the quality of the retinal image described by means of the minimum spot diameter or the root-mean-square (RMS) wavefront error. Starting from an emmetropic eye optimized for R and Q, the RMS wavefront error in the retina was 0.07 microm (far) and 1.42 microm (near). The GO resulted in a wavefront error of 1.42 microm (far) and 0.52 microm (near); improvement of near vision using reading glasses is possible. The CSI yielded 0.91 microm (far) and 0.13 microm (near); spectacles did not improve far or near vision. The DSI and CSA had significantly worse results for near and far vision. Of the options studied, GO and CSI seemed the most promising alternatives for corneal presbyopia correction. Although reading glasses can improve near vision in GO, reading glasses did not improve near vision in CSI-treated eyes. The CSI treatment is critically dependent on centration and a reverse treatment is difficult to achieve.

  2. A framework of cloud supported collaborative design in glass lens moulds based on aspheric measurement

    Science.gov (United States)

    Zhu, Yongjian; Wang, Yu; Na, Jingxin; Zhi, Yanan; Fan, Yufeng

    2013-09-01

    Aspheric mould design includes the top-down design and reversal design. In this paper, a new framework of reversal design is proposed combining with cloud supported collaborative design (CSCD) based on aspheric measurement. The framework is a kind of collaborative platform, which is composed of eight modules, including the computerized aspheric precision measurement module (CAPM), computer-aided optical design of aspheric lens system (CAOD), computer-aided design of lens mould (CADLM), FEM(finite element method) simulation of lens molding module (FEMLM), computer-aided manufacture of lens and moulds (CAMLM), measurement data analysis module (MDAM), optical product lifecycle management module (OPLM) and cloud computing network module (CCNM). In this framework, the remote clients send an improved requirement or fabrication demand about optical lens system through CCNM, which transfers this signal to OPLM. In OPLM, one main server is in charge of the task distribution and collaborative work of other six modules. The first measurement data of aspheric lens are produced by clients or our proposed platform CAPM, then are sent to CAOD for optimization and the electronic drawings of lens moulds are generated in CADLM module. According the design drawings, the FEMLM could give the lens-molding simulation parameters through FEM software. The simulation data are used for the second design of moulds in CADLM module. In this case, the moulds could be fabricated in CAMLM by ultra-precision machine, and the aspheric lens could be also produced by lens-molding machine in CAMLM. At last, the final shape of aspheric lens could be measured in CAPM and the data analysis could be conducted in MDAM module. Through the proposed framework, all the work described above could be performed coordinately. And the optimum design data of lens mould could be realized and saved, then shared by all the work team.

  3. Wavefront-guided scleral lens correction in keratoconus.

    Science.gov (United States)

    Marsack, Jason D; Ravikumar, Ayeswarya; Nguyen, Chi; Ticak, Anita; Koenig, Darren E; Elswick, James D; Applegate, Raymond A

    2014-10-01

    To examine the performance of state-of-the-art wavefront-guided scleral contact lenses (wfgSCLs) on a sample of keratoconic eyes, with emphasis on performance quantified with visual quality metrics, and to provide a detailed discussion of the process used to design, manufacture, and evaluate wfgSCLs. Fourteen eyes of seven subjects with keratoconus were enrolled and a wfgSCL was designed for each eye. High-contrast visual acuity and visual quality metrics were used to assess the on-eye performance of the lenses. The wfgSCL provided statistically lower levels of both lower-order root mean square (RMS) (p scleral contact lens. The wfgSCL provided lower levels of lower-order RMS than a normal group of well-corrected observers (p scleral contact lenses are capable of optically compensating for the deleterious effects of higher-order aberration concomitant with the disease and can provide visual image quality equivalent to that seen in normal eyes. Longer-duration studies are needed to assess whether the visual system of the highly aberrated eye wearing a wfgSCL is capable of producing visual performance levels typical of the normal population.

  4. [Correct contact lens hygiene].

    Science.gov (United States)

    Blümle, S; Kaercher, T; Khaireddin, R

    2013-06-01

    Although contact lenses have long been established in ophthalmology, practical aspects of handling contact lenses is becoming increasingly less important in the clinical training as specialist for ophthalmology. Simultaneously, for many reasons injuries due to wearing contact lenses are increasing. In order to correct this discrepancy, information on contact lenses and practical experience with them must be substantially increased from a medical perspective. This review article deals with the most important aspects for prevention of complications, i.e. contact lens hygiene.

  5. Single lens photometric machine vision with 3D imaging for fiber-to-chip coupling.

    Science.gov (United States)

    Liu, Xu; Hu, Hongmei; Sun, Xiaohan

    2012-03-01

    A single lens photometric machine vision (SLPMV) optical microbench is presented and built for fiber-to-chip coupling. By a rotation mechanics in SLPMV, the multi-view-camera can scan the various surface status of the chips coupled. To realize 3D imaging more explicitly, the modified photometric stereo algorithm is proposed through acquiring the images of weak saturation, matching the scanning illuminative angles, and rectifying rectangularly the original images. The reconstructed images have had similar qualities as those obtained by scanning electron microscopy and have unveiled the detailed information obscured in the 2D images. For the InP-based optical waveguide chip coupled with wedge-shaped fiber, the insertion loss tested on the SLPMV is 3 dB less than one on the conventional testing station. The SLPMV could serve as a more cost-effective and compact scientific observation instrumentation in imaging informatics than commercial ones.

  6. A novel scheme for high-quality 120 GHz optical millimeter-wave generation without optical filter

    Science.gov (United States)

    Zhu, Zihang; Zhao, Shanghong; Li, Yongjun; Chen, Xiaoping; Li, Xuan

    2015-01-01

    A novel scheme to generate 120 GHz millimeter (mm)-wave from 10 GHz radio frequency (RF) local oscillator (LO) with an integrated nested Mach-Zehnder modulator (MZM) is proposed and demonstrated. By properly adjusting the modulator dc bias voltages and the LO voltages and phases, a frequency of 12-tupling optical mm-wave with an optical sideband suppression ratio (OSSR) higher than 37 dB can be generated without optical filter. This scheme largely reduces the response frequency of the modulator and the LO frequency. Furthermore, the non-ideal nested MZM parameters are analyzed theoretically, and we find that both the imperfect extinction ratio of the MZM and the phase imbalance between two arms of optical coupler have an influence on the performance of the generated optical mm-wave.

  7. Image quality, meteorological optical range, and fog particulate number evaluation using the Sandia National Laboratories fog chamber

    Science.gov (United States)

    Birch, Gabriel C.; Woo, Bryana L.; Sanchez, Andres L.; Knapp, Haley

    2017-08-01

    The evaluation of optical system performance in fog conditions typically requires field testing. This can be challenging due to the unpredictable nature of fog generation and the temporal and spatial nonuniformity of the phenomenon itself. We describe the Sandia National Laboratories fog chamber, a new test facility that enables the repeatable generation of fog within a 55 m×3 m×3 m (L×W×H) environment, and demonstrate the fog chamber through a series of optical tests. These tests are performed to evaluate system image quality, determine meteorological optical range (MOR), and measure the number of particles in the atmosphere. Relationships between typical optical quality metrics, MOR values, and total number of fog particles are described using the data obtained from the fog chamber and repeated over a series of three tests.

  8. Contact lens surface changes after exposure to surfactant and abrasive cleaning procedures.

    Science.gov (United States)

    Doell, G B; Palombi, D L; Egan, D J; Huff, J W

    1986-06-01

    Proper lens maintenance is required if contact lens wear is to be successful. Poor compliance or inadequate cleaning may lead to contact lens failures and potentially damage to the eye. With phase contrast microscopy, we addressed the effect of cleaning systems on the physical integrity of a surface-modified lens--the Silcon contact lens. Several cleaners were evaluated for their ability to clean Silcon lenses with minimal damage to the lens surface. The data demonstrated that: all cleaning techniques alter the surface appearance; scratches develop more readily on lenses received with surface irregularities; wettability does not correlate with the extent of surface scratching; recommended cleaning procedures do not directly alter the wettability of the contact lens material; and phase contrast microscopy may be a useful addition to laboratory quality control.

  9. Metasurface Enabled Wide-Angle Fourier Lens.

    Science.gov (United States)

    Liu, Wenwei; Li, Zhancheng; Cheng, Hua; Tang, Chengchun; Li, Junjie; Zhang, Shuang; Chen, Shuqi; Tian, Jianguo

    2018-04-19

    Fourier optics, the principle of using Fourier transformation to understand the functionalities of optical elements, lies at the heart of modern optics, and it has been widely applied to optical information processing, imaging, holography, etc. While a simple thin lens is capable of resolving Fourier components of an arbitrary optical wavefront, its operation is limited to near normal light incidence, i.e., the paraxial approximation, which puts a severe constraint on the resolvable Fourier domain. As a result, high-order Fourier components are lost, resulting in extinction of high-resolution information of an image. Other high numerical aperture Fourier lenses usually suffer from the bulky size and costly designs. Here, a dielectric metasurface consisting of high-aspect-ratio silicon waveguide array is demonstrated experimentally, which is capable of performing 1D Fourier transform for a large incident angle range and a broad operating bandwidth. Thus, the device significantly expands the operational Fourier space, benefitting from the large numerical aperture and negligible angular dispersion at large incident angles. The Fourier metasurface will not only facilitate efficient manipulation of spatial spectrum of free-space optical wavefront, but also be readily integrated into micro-optical platforms due to its compact size. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Prolonging contact lens wear and making contact lens wear safer.

    Science.gov (United States)

    Foulks, Gary N

    2006-02-01

    To summarize the present status of safety and efficacy of contact lens wear. Literature review. Ovid Medline searches were performed on records from 1966 through 2005 using keywords: keratitis, contact lens complications, extended-wear contact lenses, and silicone-hydrogel contact lenses. Patients desire comfort, clarity of vision, and prolonged contact lens wear when contact lenses are used to correct refractive error. Practitioners desire patient satisfaction but also require maintenance of the integrity of the eye and no complications that jeopardize vision or health of the eye. Improvements in the oxygen permeability of the contact lens materials, design of the contact lens and its surface, and solutions for the maintenance of the lens have reduced but not eliminated the risks of infection, inflammation, and conjunctival papillary reaction associated with contact lens wear. The lessons of past and recent history suggest that patient education and practitioner participation in the management of contact lens wear continue to be critical factors for patient satisfaction and safety in the extended wear of contact lenses. The availability of highly oxygen permeable contact lenses has increased the tolerance and safety of extended contact lens wear, but patient instruction and education in proper use and care of lenses is required and caution is advised.

  11. The Time Lens Concept Applied to Ultra-High-Speed OTDM Signal Processing

    DEFF Research Database (Denmark)

    Clausen, Anders; Palushani, Evarist; Mulvad, Hans Christian Hansen

    2013-01-01

    This survey paper presents some of the applications where the versatile time-lens concept successfully can be applied to ultra-high-speed serial systems by offering expected needed functionalities for future optical communication networks....

  12. Direct Multipixel Imaging and Spectroscopy of an exoplanet with a Solar Gravity Lens Mission

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to study a mission to the deep regions outside the solar system that will exploit the remarkable optical properties of the Solar Gravitational Lens (SGL)...

  13. Laser Tweezer Controlled Solid Immersion Lens for High Resolution Imaging in Microfluidic and Biological Samples

    National Research Council Canada - National Science Library

    Birkbeck, Aaron L; Zlatanovic, Sanja; Ozkan, Mihrimah; Esener, Sadik C

    2005-01-01

    ...). Up to now, solid immersion lens imaging systems have relied upon cantilever-mounted SILs that are difficult to integrate into microfluidic systems and require an extra alignment step with external optics...

  14. Laser Tweezer Controlled Solid Immersion Lens for High Resolution Imaging in Microfluidic and Biological Samples

    National Research Council Canada - National Science Library

    Birkbeck, Aaron L; Zlatanovic, Sanja; Ozkan, Mihrimah; Esener, Sadik C

    2005-01-01

    A novel technique is presented which integrates the capacity of a laser tweezer to optically trap and manipulate objects in three-dimensions with the resolution-enhanced imaging capabilities of a solid immersion lens (SIL...

  15. 1600+434 - A NEW GRAVITATIONAL LENS SYSTEM

    NARCIS (Netherlands)

    JACKSON, N; DEBRUYN, AG; MYERS, S; BREMER, MN; MILEY, GK; SCHILIZZI, RT; BROWNE, IWA; NAIR, S; WILKINSON, PN; BLANDFORD, RD; PEARSON, TJ; READHEAD, ACS

    1995-01-01

    We report the discovery of a new gravitational lens system associated with the flat-spectrum radio source 1600+434. The system has been found in a new large survey of such radio sources. It consists of a 1.4-arcsec double radio source with an associated optical double at the same position and

  16. Combination of a micro-lens multi-spot generator with a galvanometer scanner for flexible parallel micromachining of silicon

    Science.gov (United States)

    Zimmermann, Maik; Schmidt, Michael

    2011-10-01

    Multi focus optics are used for parallelizing production and for large-scale material processing. These elements split the beam into a periodic spot pattern with a defined grid and spot size. The challenge lies in the generation of a homogeneous envelope. Additionally the demand for flexible systems for an in-process changing of optical properties increases. Different components for multi spot generation like diffractive optical elements or micro lens arrays have been investigated. Diffractive optical elements offer large degree of freedom in the generation of arbitrary intensity distributions. In the paper we demonstrate the use of a diffractive element in combination with a multi spot generator. Within the paper we present the investigation of a micro lens array in a fly's eye condenser setup for the generation of homogeneous spot patterns. The multi spot generator is combined with a galvanometer scanner for forming an arbitrary shaped laser beam into a spot-, ring or arbitrary array pattern. We show the principal functionality of the multi-spot generator. Furthermore constrains of this setup are demonstrated. The multi spot scanner is used for micro structuring of silicon with a nanosecond diode pumped solid state laser. The ablation rate and structure quality are compared to single spot processing.

  17. Development of high precision and cryogenic lens holders

    Science.gov (United States)

    Reutlinger, A.; Boesz, Anton; Mottaghibonab, A.; Eckert, P.; Dubowy, M.; Gebler, H.; Grupp, F.; Geis, N.; Bode, A.; Katterloher, R.; Bender, R.

    2017-11-01

    The optical system of the Near Infrared Spectrometer and Photometer (NISP) of the EUCLID mission consists mainly of a filter and grism wheel and 4 aspherical lenses with large diameters up to 170 mm. The single lenses require a high precision positioning at the operational temperature of 150 K. An additional design driver represents the CaF2 material of a lens, which is very sensitive wrt brittleness. The technical maturity of the combination of single features such as CaF2, large diameter (and mass), high precision and cryogenic conditions is considered as low. Therefore, a dedicated pre-development program has been launched to design and develop a first prototype of lens holder and to demonstrate the functional performance at representative operational conditions. The 4 lenses are divided into 3x lenses for the Camera Lens Assembly (CaLA) and 1x lens for the Corrector Lens Assembly (CoLA). Each lens is glue mounted onto solid state springs, part of an adaption ring. The adaption ring shall provide protection against vibration loads, high accuracy positioning, as well as quasi load free mounting of the lens under operational conditions. To reduce thermomechanical loads on the lens, the CTE of the adaption ring is adapted to that of the lens. The glue between lens and solid state spring has to withstand high tension loads during vibration. At the operational temperature the deviating CTE between glue and lens/adaption ring introduces shear loads into the glue interface, which are critical, in particular for the fragile CaF2 lens material. For the case of NISP the shear loads are controlled with the glue pad diameter and the glue thickness. In the context of the development activity many technology aspects such as various solid state spring designs, glue selection and glue handling have been investigated. A parametric structural model was developed to derive the specific design feature of each ring, such as spring force, number of springs, eigenfrequency, etc. This

  18. Growth and optical characteristics of high-quality ZnO thin films on graphene layers

    Directory of Open Access Journals (Sweden)

    Suk In Park

    2015-01-01

    Full Text Available We report the growth of high-quality, smooth, and flat ZnO thin films on graphene layers and their photoluminescence (PL characteristics. For the growth of high-quality ZnO thin films on graphene layers, ZnO nanowalls were grown using metal-organic vapor-phase epitaxy on oxygen-plasma treated graphene layers as an intermediate layer. PL measurements were conducted at low temperatures to examine strong near-band-edge emission peaks. The full-width-at-half-maximum value of the dominant PL emission peak was as narrow as 4 meV at T = 11 K, comparable to that of the best-quality films reported previously. Furthermore, the stimulated emission of ZnO thin films on the graphene layers was observed at the low excitation energy of 180 kW/cm2 at room temperature. Their structural and optical characteristics were investigated using X-ray diffraction, transmission electron microscopy, and PL spectroscopy.

  19. Evaluation of double-pass optical quality analysis system between SMILE and femtosecond LASIK for myopia

    Directory of Open Access Journals (Sweden)

    Wen-Jing Li

    2014-11-01

    Full Text Available AIM: To evaluate the visual quality between femtosecond laser small incision lenticule extraction(SMILEand femtosecond laser in situ keratomileusis(LASIKin the treatment of myopia. METHODS: This study comprised 22 eyes(11 patientsunderwent SMILE and 43 eyes(23 patientsreceived LASIK with femtosecond laser to correct myopia and myopic astigmatism. The two groups were recorded bydouble-pass optical quality analysis system(OQASat preoperative and postoperative 1mo. The two groups were compared: modulation transfer function cutoff frequency(MTF cutoff, strehl ratio(SR, objective scattering index(OSI. The early visual quality after operation between two groups were analyzed and evaluated.RESULTS: The MTF cutoff after operation one month were 34.835±10.113c/deg(SMILE groupand 38.362±10.623c/deg(LASIK group(t=0.925, P=0.362. The SR after operation one month were 0.204±0.077(SMILE groupand 0.218±0.072(LASIK group(t=0.557, P=0.582. The OSI after operation one month were 0.608±0.291(SMILE groupand 0.545±0.405(LASIK group(t=-0.473, P=0.640. CONCLUSION: The double-pass OQAS tell us that there was not statistically significant between femtosecond laser SMILE and femtosecond LASIK in the treatment of myopia.

  20. Modified x-ray polymer refractive cross lens with adiabatic contraction and its realization

    International Nuclear Information System (INIS)

    Nazmov, V; Mohr, J; Greving, I; Ogurreck, M; Wilde, F

    2015-01-01

    A refractive x-ray lens with reduced focal length, due to continuous reduction in the designed aperture over the length of the lens, is presented. The lens elements have refractive parabolic sidewalls like geometrical prisms, with a varying cross section over the length of the lens, in accordance with the x-ray propagation law. The focusing effect occurs directly in the lens due to the fact that the initial x-ray beam is directed toward the focal point, and due to the phase retardation caused by the refractive properties of the sidewall surfaces. An array of such adiabatic lens elements with different optical parameters, arranged in a number of rows, represented by polymer microstructures, has been produced using x-ray lithography. Preliminary testing of the lenses has resulted in a focal spot of 67 nm at a photon energy of 18.6 keV. (paper)

  1. Geometry-invariant GRIN lens: iso-dispersive contours

    Science.gov (United States)

    Bahrami, Mehdi; Goncharov, Alexander V.

    2012-01-01

    A dispersive model of a gradient refractive index (GRIN) lens is introduced based on the idea of iso-dispersive contours. These contours have constant Abbe number and their shape is related to iso-indicial contours of the monochromatic geometry-invariant GRIN lens (GIGL) model. The chromatic GIGL model predicts the dispersion throughout the GRIN structure by using the dispersion curves of the surface and the center of the lens. The analytical approach for paraxial ray tracing and the monochromatic aberration calculations used in the GIGL model is employed here to derive closed-form expressions for the axial and lateral color coefficients of the lens. Expressions for equivalent refractive index and the equivalent Abbe number of the homogeneous equivalent lens are also presented and new aspects of the chromatic aberration change due to aging are discussed. The key derivations and explanations of the GRIN lens optical properties are accompanied with numerical examples for the human and animal eye GRIN lenses. PMID:22808438

  2. New process for high optical quality InAs quantum dots grown on patterned GaAs(001) substrates

    International Nuclear Information System (INIS)

    Alonso-Gonzalez, Pablo; Gonzalez, Luisa; Gonzalez, Yolanda; Fuster, David; Fernandez-Martinez, Ivan; Martin-Sanchez, Javier; Abelmann, Leon

    2007-01-01

    This work presents a selective ultraviolet (UV)-ozone oxidation-chemical etching process that has been used, in combination with laser interference lithography (LIL), for the preparation of GaAs patterned substrates. Further molecular beam epitaxy (MBE) growth of InAs results in ordered InAs/GaAs quantum dot (QD) arrays with high optical quality from the first layer of QDs formed on the patterned substrate. The main result is the development of a patterning technology that allows the engineering of customized geometrical displays of QDs with the same optical quality as those formed spontaneously on flat non-patterned substrates

  3. New process for high optical quality InAs quantum dots grown on patterned GaAs(001) substrates

    Energy Technology Data Exchange (ETDEWEB)

    Alonso-Gonzalez, Pablo [Instituto de Microelectronica de Madrid (CNM, CSIC), Isaac Newton 8, 28760, Tres Cantos, Madrid (Spain); Gonzalez, Luisa [Instituto de Microelectronica de Madrid (CNM, CSIC), Isaac Newton 8, 28760, Tres Cantos, Madrid (Spain); Gonzalez, Yolanda [Instituto de Microelectronica de Madrid (CNM, CSIC), Isaac Newton 8, 28760, Tres Cantos, Madrid (Spain); Fuster, David [Instituto de Microelectronica de Madrid (CNM, CSIC), Isaac Newton 8, 28760, Tres Cantos, Madrid (Spain); Fernandez-Martinez, Ivan [Instituto de Microelectronica de Madrid (CNM, CSIC), Isaac Newton 8, 28760, Tres Cantos, Madrid (Spain); Martin-Sanchez, Javier [Instituto de Microelectronica de Madrid (CNM, CSIC), Isaac Newton 8, 28760, Tres Cantos, Madrid (Spain); Abelmann, Leon [SMI, MESA Institute of Nanotechnology, University of Twente, PO Box 217, 7500 AE, Enschede (Netherlands)

    2007-09-05

    This work presents a selective ultraviolet (UV)-ozone oxidation-chemical etching process that has been used, in combination with laser interference lithography (LIL), for the preparation of GaAs patterned substrates. Further molecular beam epitaxy (MBE) growth of InAs results in ordered InAs/GaAs quantum dot (QD) arrays with high optical quality from the first layer of QDs formed on the patterned substrate. The main result is the development of a patterning technology that allows the engineering of customized geometrical displays of QDs with the same optical quality as those formed spontaneously on flat non-patterned substrates.

  4. Two families of astrophysical diverging lens models

    Science.gov (United States)

    Er, Xinzhong; Rogers, Adam

    2018-03-01

    In the standard gravitational lensing scenario, rays from a background source are bent in the direction of a foreground lensing mass distribution. Diverging lens behaviour produces deflections in the opposite sense to gravitational lensing, and is also of astrophysical interest. In fact, diverging lensing due to compact distributions of plasma has been proposed as an explanation for the extreme scattering events that produce frequency-dependent dimming of extragalactic radio sources, and may also be related to the refractive radio wave phenomena observed to affect the flux density of pulsars. In this work we study the behaviour of two families of astrophysical diverging lenses in the geometric optics limit, the power law, and the exponential plasma lenses. Generally, the members of these model families show distinct behaviour in terms of image formation and magnification, however the inclusion of a finite core for certain power-law lenses can produce a caustic and critical curve morphology that is similar to the well-studied Gaussian plasma lens. Both model families can produce dual radial critical curves, a novel distinction from the tangential distortion usually produced by gravitational (converging) lenses. The deflection angle and magnification of a plasma lens vary with the observational frequency, producing wavelength-dependent magnifications that alter the amplitudes and the shape of the light curves. Thus, multiwavelength observations can be used to physically constrain the distribution of the electron density in such lenses.

  5. Laboratory Demonstration of Axicon-Lens Coronagraph

    Science.gov (United States)

    Choi, Jaeho; Jea, Geonho

    2018-01-01

    The results of laboratory based experiments of the proposed coronagraph using axicon-lenses that is conjunction with a method of noninterferometric quantitative phase imaging for direct imaging of exoplanets is will present. The light source is passing through tiny holes drilled on the thin metal plate is used as the simulated stellar and its companions. Those diffracted light at the edge of the holes bears a similarity to the light from the bright stellar. Those images are evaginated about the optical axis after the maximum focal length of the first axicon lens. Then the evaginated images of have cut off using the motorized iris which means the suppressed the central stellar light preferentially. Various length between the holes which represent the angular distance are examined. The laboratory experimental results are shown that the axicon-lens coronagraph has feature of ability to achieve the smaller IWA than l/D and high-contrast direct imaging. The laboratory based axicon-lens coronagraph imaging support the symbolic computation results which has potential in direct imaging for finding exoplanet and various astrophysical activities. The setup of the coronagraph is simple to build and is durable to operate. Moreover it can be transported the planets images to a broadband spectrometric instrument that able to investigate the constituent of the planetary system.

  6. Adjustable internal structure for reconstructing gradient index profile of crystalline lens.

    Science.gov (United States)

    Bahrami, Mehdi; Goncharov, Alexander V; Pierscionek, Barbara K

    2014-03-01

    Employing advanced technologies in studying the crystalline lens of the eye has improved our understanding of the refractive index gradient of the lens. Reconstructing and studying such a complex structure requires models with adaptable internal geometry that can be altered to simulate geometrical and optical changes of the lens with aging. In this Letter, we introduce an optically well-defined, geometrical structure for modeling the gradient refractive index profile of the crystalline lens with the advantage of an adjustable internal structure that is not available with existing models. The refractive index profile assigned to this rotationally symmetric geometry is calculated numerically, yet it is shown that this does not limit the model. The study provides a basis for developing lens models with sophisticated external and internal structures without the need for analytical solutions to calculate refractive index profiles.

  7. Lateral refraction and reflection of light polarized lenses principle. Coplanar lens systems

    International Nuclear Information System (INIS)

    Miranda, L.

    2012-01-01

    Studying the behavior of the linearly polarized light to impact a lens and in the lens itself, resulted in the discovery of a physical principle of optics, not mentioned or used so far. This phenomenon is very useful in practice. Perhaps the manifestation of the phenomenon occurs in the plane perpendicular to the road or optical axis, is due the reason that was not seen before, but it has always been there when polarized light passes through a lens. Known and mastered the principle has been manipulated for better research results, using for the first time a planar lens system, which according to the placement of the lens allows for accurate lags between the light beams ar the exits the system. (Author)

  8. A Novel Method for Fabricating Additive Manufactured Lightweight, Optical Quality Metallic Mirrors

    Science.gov (United States)

    2016-01-04

    1    A Novel Method for Fabricating Additive Manufactured  Lightweight, Optical Quality Metallic  Mirrors   Michael Stern, Joseph Bari  Distribution A...metallic  mirrors  fabricated by growing an additive manufactured blank, post  processing the faces, coating with electroless nickel, and diamond turning...low‐weight spinning  mirror , in which topology  optimization was used. The blank was then fabricated with metallic powder bed fusion and post

  9. Design of slotted high quality factor photonic-crystal nanocavities embedded in electro-optic polymers

    Science.gov (United States)

    Nakadai, Masahiro; Konoike, Ryotaro; Tanaka, Yoshinori; Asano, Takashi; Noda, Susumu

    2017-09-01

    We improve design quality factors of slotted photonic crystal nanocavities embedded in electro-optic polymers (EOPs), which enables control of resonant wavelengths without the use of light-absorbing free carriers. We form nanocavities by modifying single- and double-slotted line-defect waveguides with lattice-constant modulations analytically determined based on dispersions of the waveguides. A double-slotted nanocavity achieves a fourfold increase in Q factor (36 million) compared to a single-slotted nanocavity with similar modulation of lattice constants. Both structures can realize large concentration of light in the EOP region (50%), and resonant wavelength modulations of ∼0.01% are expected with applied voltage of 2 V.

  10. Optical quality assurance procedures for the sensors of CBM STS detector

    Energy Technology Data Exchange (ETDEWEB)

    Lavrik, Evgeny [Physikalisches Institut der Universitaet Tuebingen (Germany); Collaboration: CBM-Collaboration

    2016-07-01

    The Compressed Baryonic Matter (CBM) experiment at FAIR aims to study the properties of nuclear matter at high net-baryon densities. The Silicon Tracking System (STS) is the key detector to reconstruct charged particle tracks created in heavy-ion interactions. In order to assure the quality of about 1300 silicon sensors, highly efficient and highly automated procedures need to be developed. In this contribution we report on a microscope camera based optical inspection system, used to scan along the individual sensors to recognize and classify sensor defects. Examples of these defects are: photo-resist residues, top metallization layer lithography defects, surface scratches. In order to separate and classify these defects various image-processing algorithms are used, including: pattern recognition, object classification etc.

  11. Image quality improvement in a hard X-ray projection microscope using total reflection mirror optics.

    Science.gov (United States)

    Mimura, Hidekazu; Yamauchi, Kazuto; Yamamura, Kazuya; Kubota, Akihisa; Matsuyama, Satoshi; Sano, Yasuhisa; Ueno, Kazumasa; Endo, Katsuyoshi; Nishino, Yoshinori; Tamasaku, Kenji; Yabashi, Makina; Ishikawa, Tetsuya; Mori, Yuzo

    2004-07-01

    A new figure correction method has been applied in order to fabricate an elliptical mirror to realize a one-dimensionally diverging X-ray beam having high image quality. Mutual relations between figure errors and intensity uniformities of diverging X-ray beams have also been investigated using a wave-optical simulator and indicate that figure errors in relatively short spatial wavelength ranges lead to high-contrast interference fringes. By using a microstitching interferometer and elastic emission machining, figure correction of an elliptical mirror with a lateral resolution close to 0.1 mm was carried out. A one-dimensional diverging X-ray obtained using the fabricated mirror was observed at SPring-8 and evaluated to have a sufficiently flat intensity distribution.

  12. Recommendations for assessing patient-reported outcomes and health-related quality of life in patients with urticaria: a GA(2) LEN taskforce position paper

    DEFF Research Database (Denmark)

    Baiardini, I; Braido, F; Bindslev-Jensen, Carsten

    2011-01-01

    ) and the chronic urticaria questionnaire on quality of life CU-Q(2)oL. This latter tool, CU-Q(2)oL, is available in many languages and should be preferred, where available, over more generic instruments for assessing urticaria-specific effects on quality of life. CU-Q(2)oL is only suited for the investigation...... in clinical trials and routine practice for the evaluation of urticaria patients. We suggest that PROs should be considered as the primary outcome of future clinical trials. Two validated and disease-specific instruments for assessing PROs are available, the urticaria activity score (for symptoms...... of patients with chronic spontaneous urticaria. Similar instruments for other forms of urticaria have yet to be developed and validated. Also, tools for assessing other chronic spontaneous urticaria PROs besides quality of life and symptoms are needed....

  13. Water quality monitoring using an automated portable fiber optic biosensor: RAPTOR

    Science.gov (United States)

    Anderson, George P.; Rowe-Taitt, Chris A.

    2001-03-01

    The RAPTOR is a portable, automated biosensor capable of performing rapid, ten-minute assays on a sample for four target analytes simultaneously. Samples are analyzed using a fluorescent sandwich immunoassay on the surface of short polystyrene optical probes with capture antibody adsorbed to the probe surface. Target analytes bound to the fiber by capture antibodies are detected with fluorescently labeled tracer antibodies, which are held in a separate reservoir. Since target recognition is a two-step process, selectivity is enhanced, and the optical probes can be reused up to forty times, or until a positive result is obtained. This greatly reduces the logistical burden for field operations. Numerous assays for toxins, such as SEB and ricin, and bacteria, such as Bacillus anthracis and Francisella tularensis, have been developed for the RAPTOR. An assay of particular interest for water quality monitoring and the screening of fruits and vegetables is detection of Giardia cysts. Giardia lamblia is a parasitic protozoan common in the developing world that causes severe intestinal infections. Thus, a simple field assay for screening water supplies would be highly useful. Such an assay has been developed using the RAPTOR. The detection limit for Giardia cysts was 5x104/ml for a 10-minute assay.

  14. Approaching the Challenge of Student Retention through the Lens of Quality Control: A Conceptual Model of University Business Student Retention Utilizing Six Sigma

    Science.gov (United States)

    Jenicke, Lawrence O.; Holmes, Monica C.; Pisani, Michael J.

    2013-01-01

    Student retention in higher education is a major issue as academic institutions compete for fewer students and face declining enrollments. A conceptual model of applying the quality improvement methodology of Six Sigma to the problem of undergraduate student retention in a college of business is presented. Improvement techniques such as cause and…

  15. Aspherical Lens Design Using Genetic Algorithm for Reducing Aberrations in Multifocal Artificial Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Chih-Ta Yen

    2015-09-01

    Full Text Available A complex intraocular lens (IOL design involving numerous uncertain variables is proposed. We integrated a genetic algorithm (GA with the commercial optical design software of (CODE V to design a multifocal IOL for the human eye. We mainly used an aspherical lens in the initial state to the crystalline type; therefore, we used the internal human eye model in the software. The proposed optimized algorithm employs a GA method for optimally simulating the focusing function of the human eye; in this method, the thickness and curvature of the anterior lens and the posterior part of the IOL were varied. A comparison of the proposed GA-designed IOLs and those designed using a CODE V built-in optimal algorithm for 550 degrees myopia and 175 degrees astigmatism conditions of the human eye for pupil size 6 mm showed that the proposed IOL design improved the spot size of root mean square (RMS, tangential coma (TCO and modulation transfer function (MTF at a spatial frequency of 30 with a pupil size of 6 mm by approximately 17%, 43% and 35%, respectively. However, the worst performance of spherical aberration (SA was lower than 46%, because the optical design involves a tradeoff between all aberrations. Compared with the traditional CODE V built-in optimal scheme, the proposed IOL design can efficiently improve the critical parameters, namely TCO, RMS, and MTF.

  16. Compliance among soft contact lens wearers.

    OpenAIRE

    Kuzman, Tomislav; Barišić Kutija, Marija; Masnec, Sanja; Jandroković, Sonja; Mrazovac, Danijela; Jurišić, Darija; Škegro, Ivan; Kalauz, Miro; Kordić, Rajko

    2014-01-01

    Contact lens compliance is proven to be crucial for preventing lens wear-related complications because of the interdependence of the steps in lens care regime and their influence on lens system microbial contamination. Awareness of the patients' lens handling compliance as well as correct recognition of non-compliant behaviours is the basis for creating more targeted strategies for patient education. The aim of this study was to investigate compliance among soft contact lens (SCL) wearers in ...

  17. Adaptive tool servo diamond turning for enhancing machining efficiency and surface quality of freeform optics.

    Science.gov (United States)

    Zhu, Zhiwei; To, Suet

    2015-08-10

    Fast tool servo/ slow tool servo (FTS/STS) diamond turning is a very promising technique for the generation of freeform optics. However, the currently adopted constant scheme for azimuth sampling and side-feeding motion possesses no adaptation to surface shape variation, leading to the non-uniform surface quality and low machining efficiency. To overcome this defect, this paper reports on a novel adaptive tool servo (ATS) diamond turning technique which is essentially based on the novel two-degree-of-freedom (2-DOF) FTS/STS. In the ATS, the sampling interval and the side-feeding motion are actively controlled at any cutting point to adapt the machining process to shape variation of the desired surface, making both the sampling induced interpolation error and the side-feeding induced residual tool mark be within the desired tolerances. Characteristic of the required cutting motion suggests that besides the conventional z-axis servo motion, another servo motion along the x-axis synthesizing by the c-axis is mandatory for implementing the ATS. Comparative studies of surface generation of typical micro-structured surfaces in FTS/STS and ATS are thoroughly conducted both theoretically and experimentally. The result demonstrates that the ATS outperforms the FTS/STS with improved surface quality while simultaneously enhanced machining efficiency.

  18. Assimilation of next generation geostationary aerosol optical depth retrievals to improve air quality simulations

    Science.gov (United States)

    Saide, Pablo E.; Kim, Jhoon; Song, Chul H.; Choi, Myungje; Cheng, Yafang; Carmichael, Gregory R.

    2014-12-01

    Planned geostationary satellites will provide aerosol optical depth (AOD) retrievals at high temporal and spatial resolution which will be incorporated into current assimilation systems that use low-Earth orbiting (e.g., Moderate Resolution Imaging Spectroradiometer (MODIS)) AOD. The impacts of such additions are explored in a real case scenario using AOD from the Geostationary Ocean Color Imager (GOCI) on board of the Communication, Ocean, and Meteorology Satellite, a geostationary satellite observing northeast Asia. The addition of GOCI AOD into the assimilation system generated positive impacts, which were found to be substantial in comparison to only assimilating MODIS AOD. We found that GOCI AOD can help significantly to improve surface air quality simulations in Korea for dust, biomass burning smoke, and anthropogenic pollution episodes when the model represents the extent of the pollution episodes and retrievals are not contaminated by clouds. We anticipate future geostationary missions to considerably contribute to air quality forecasting and provide better reanalyses for health assessments and climate studies.

  19. Optical Coherence Tomography Technology and Quality Improvement Methods for Optical Coherence Tomography Images of Skin: A Short Review

    Science.gov (United States)

    Adabi, Saba; Turani, Zahra; Fatemizadeh, Emad; Clayton, Anne; Nasiriavanaki, Mohammadreza

    2017-01-01

    Optical coherence tomography (OCT) delivers 3-dimensional images of tissue microstructures. Although OCT imaging offers a promising high-resolution method, OCT images experience some artifacts that lead to misapprehension of tissue structures. Speckle, intensity decay, and blurring are 3 major artifacts in OCT images. Speckle is due to the low coherent light source used in the configuration of OCT. Intensity decay is a deterioration of light with respect to depth, and blurring is the consequence of deficiencies of optical components. In this short review, we summarize some of the image enhancement algorithms for OCT images which address the abovementioned artifacts. PMID:28638245

  20. Optical Coherence Tomography Technology and Quality Improvement Methods for Optical Coherence Tomography Images of Skin: A Short Review

    Directory of Open Access Journals (Sweden)

    Saba Adabi

    2017-06-01

    Full Text Available Optical coherence tomography (OCT delivers 3-dimensional images of tissue microstructures. Although OCT imaging offers a promising high-resolution method, OCT images experience some artifacts that lead to misapprehension of tissue structures. Speckle, intensity decay, and blurring are 3 major artifacts in OCT images. Speckle is due to the low coherent light source used in the configuration of OCT. Intensity decay is a deterioration of light with respect to depth, and blurring is the consequence of deficiencies of optical components. In this short review, we summarize some of the image enhancement algorithms for OCT images which address the abovementioned artifacts.

  1. High axial resolution Raman probe made of a single hollow optical fiber.

    Science.gov (United States)

    Katagiri, Takashi; Yamamoto, Yuko S; Ozaki, Yukihiro; Matsuura, Yuji; Sato, Hidetoshi

    2009-01-01

    A ball lens mounted hollow optical fiber Raman probe (BHRP) consisting of a single hollow optical fiber (HOF) and a micro-ball lens was developed for performing a high axial resolution and high-sensitivity remote Raman analysis of biomedical tissues. The total diameter of the probe head is 640 microm. The BHRP is useful in the measurement of thin-layered tissues that are in contact with the probe's surface because the probe has a limited depth-of-field optical property. An optical calculation study suggested that it is possible to vary the probe's working distance by selecting different materials and diameters for the ball lens. Empirical studies revealed that this probe has a higher axial resolution and a higher sensitivity than an HOF Raman probe without the ball lens. The spectrum of a mouse stomach measured with the BHRP had better quality and considerably lower noise than that measured with a conventional Raman microscope. These results strongly suggest that the BHRP can be used effectively in biomedical applications.

  2. Nanofocusing optics for synchrotron radiation made from polycrystalline diamond.

    Science.gov (United States)

    Fox, O J L; Alianelli, L; Malik, A M; Pape, I; May, P W; Sawhney, K J S

    2014-04-07

    Diamond possesses many extreme properties that make it an ideal material for fabricating nanofocusing x-ray optics. Refractive lenses made from diamond are able to focus x-ray radiation with high efficiency but without compromising the brilliance of the beam. Electron-beam lithography and deep reactive-ion etching of silicon substrates have been used in a transfer-molding technique to fabricate diamond optics with vertical and smooth sidewalls. Latest generation compound refractive lenses have seen an improvement in the quality and uniformity of the optical structures, resulting in an increase in their focusing ability. Synchrotron beamline tests of two recent lens arrays, corresponding to two different diamond morphologies, are described. Focal line-widths down to 210 nm, using a nanocrystalline diamond lens array and a beam energy of E = 11 keV, and 230 nm, using a microcrystalline diamond lens at E = 15 keV, have been measured using the Diamond Light Source Ltd. B16 beamline. This focusing prowess is combined with relatively high transmission through the lenses compared with silicon refractive designs and other diffractive optics.

  3. Hyperbolic metamaterial lens with hydrodynamic nonlocal response

    DEFF Research Database (Denmark)

    Yan, Wei; Mortensen, N. Asger; Wubs, Martijn

    2013-01-01

    We investigate the effects of hydrodynamic nonlocal response in hyperbolic metamaterials (HMMs), focusing on the experimentally realizable parameter regime where unit cells are much smaller than an optical wavelength but much larger than the wavelengths of the longitudinal pressure waves of the f......We investigate the effects of hydrodynamic nonlocal response in hyperbolic metamaterials (HMMs), focusing on the experimentally realizable parameter regime where unit cells are much smaller than an optical wavelength but much larger than the wavelengths of the longitudinal pressure waves...... in the local-response approximation and in the hydrodynamic Drude model can differ considerably. In particular, the optimal frequency for imaging in the nonlocal theory is blueshifted with respect to that in the local theory. Thus, to detect whether nonlocal response is at work in a hyperbolic metamaterial, we...... propose to measure the near-field distribution of a hyperbolic metamaterial lens....

  4. Ray-tracing study on the post-scanner variable beam expansion optics in a two-photon microscopy system

    Science.gov (United States)

    Kim, Do-Hyun; Welle, Cristin; Krauthamer, Victor

    2012-03-01

    Due to the low signal levels typical of two-photon microscopy (TPM) in biological samples, optical design optimization is critical. One of the most important factors is overfilling of the back aperture of the objective lens. A variable beam expander is commonly placed before the scanning mirrors to achieve this goal, however, this may cause degradation of image quality due to increased dispersion. Additionally, scanning mirror size restricts the degree of expansion, which often prevents the overfilling of objective lens back aperture. We investigated the implementation of variable beam expansion optics after the scanning mirrors. Ray-tracing analyses confirmed that the post-scanner beam expansion has two key advantages over the conventional pre-scanner beam expansion approach: decreasing the number of optical elements reduces pulse dispersion and reducing the size of the scanning mirror enables faster scanning. Resolution and aberration of a TPM with post-scanner beam expansion optics were analysed.

  5. Crystalline lens radioprotectors

    International Nuclear Information System (INIS)

    Belkacemi, Y.; Pasquier, D.; Castelain, B.; Lartigau, E.; Warnet, J.M.

    2003-01-01

    During more than a half of century, numerous compounds have been tested in different models against radiation-induced cataract. In this report, we will review the radioprotectors that have been already tested for non-human crystalline lens protection. We will focus on the most important published studies in this topic and the mechanisms of cyto-protection reported in. vitro and in. vivo from animals. The most frequent mechanisms incriminated in the cyto-protective effect are: free radical scavenging, limitation of lipid peroxidation, modulation of cycle progression increase of intracellular reduced glutathione pool, reduction of DNA strand breaks and limitation of apoptotic cell death. Arnifostine (or Ethyol) and anethole dithiolethione (or Sulfarlem), already used clinically as chemo- and radio-protectants, could be further test?r for ocular radioprotection particularly for radiation-induced cataract. (author)

  6. The balanced two-string technique for sulcus intraocular lens implantation in the absence of capsular support.

    Science.gov (United States)

    Ibrahim, Hesham A; Sabry, Heba Nabil

    2015-01-01

    Purpose. To describe and explore an alternative approach for sulcus intraocular lens (IOL) implantation in the absence of capsular support. Methods. The commonly available one-piece poly(methyl methacrylate) (PMMA) lens is stabilized in the sulcus by two intraocular horizontal strings of 10/0 polypropylene suture passed through the lens dialing holes in opposite directions to achieve a mechanical balance. The horizontal strings of 10/0 polypropylene work as a rail track for the IOL optics, allowing some side to side lens adjustment even following wound closure. The stability of the IOL was tested in vitro. Six aphakic patients underwent in-sulcus IOL secondary implantation using the balanced two-string technique. Patients were followed up for a minimum of six months. Best spectacle corrected vision was assessed. Lens centration and lens tilt were measured by anterior segment optical coherence tomography (AS-OCT). Results. All patients had successful lens insertion. Best spectacle corrected visual acuity (BSCVA) improved in all patients. Lens decentration ranged between 0.21 mm and 0.9 mm (average 0.53 mm). Lens tilt ranged between 1.2° and 2.8° (average 2.17°). Conclusion. The mechanically balanced two-string technique is an alternative option for sulcus IOL implantation in absence of capsular support, allowing lens centration adjustment with no additional risks.

  7. The Balanced Two-String Technique for Sulcus Intraocular Lens Implantation in the Absence of Capsular Support

    Science.gov (United States)

    Ibrahim, Hesham A.; Sabry, Heba Nabil

    2015-01-01

    Purpose. To describe and explore an alternative approach for sulcus intraocular lens (IOL) implantation in the absence of capsular support. Methods. The commonly available one-piece poly(methyl methacrylate) (PMMA) lens is stabilized in the sulcus by two intraocular horizontal strings of 10/0 polypropylene suture passed through the lens dialing holes in opposite directions to achieve a mechanical balance. The horizontal strings of 10/0 polypropylene work as a rail track for the IOL optics, allowing some side to side lens adjustment even following wound closure. The stability of the IOL was tested in vitro. Six aphakic patients underwent in-sulcus IOL secondary implantation using the balanced two-string technique. Patients were followed up for a minimum of six months. Best spectacle corrected vision was assessed. Lens centration and lens tilt were measured by anterior segment optical coherence tomography (AS-OCT). Results. All patients had successful lens insertion. Best spectacle corrected visual acuity (BSCVA) improved in all patients. Lens decentration ranged between 0.21 mm and 0.9 mm (average 0.53 mm). Lens tilt ranged between 1.2° and 2.8° (average 2.17°). Conclusion. The mechanically balanced two-string technique is an alternative option for sulcus IOL implantation in absence of capsular support, allowing lens centration adjustment with no additional risks. PMID:25722884

  8. The Balanced Two-String Technique for Sulcus Intraocular Lens Implantation in the Absence of Capsular Support

    Directory of Open Access Journals (Sweden)

    Hesham A. Ibrahim

    2015-01-01

    Full Text Available Purpose. To describe and explore an alternative approach for sulcus intraocular lens (IOL implantation in the absence of capsular support. Methods. The commonly available one-piece poly(methyl methacrylate (PMMA lens is stabilized in the sulcus by two intraocular horizontal strings of 10/0 polypropylene suture passed through the lens dialing holes in opposite directions to achieve a mechanical balance. The horizontal strings of 10/0 polypropylene work as a rail track for the IOL optics, allowing some side to side lens adjustment even following wound closure. The stability of the IOL was tested in vitro. Six aphakic patients underwent in-sulcus IOL secondary implantation using the balanced two-string technique. Patients were followed up for a minimum of six months. Best spectacle corrected vision was assessed. Lens centration and lens tilt were measured by anterior segment optical coherence tomography (AS-OCT. Results. All patients had successful lens insertion. Best spectacle corrected visual acuity (BSCVA improved in all patients. Lens decentration ranged between 0.21 mm and 0.9 mm (average 0.53 mm. Lens tilt ranged between 1.2° and 2.8° (average 2.17°. Conclusion. The mechanically balanced two-string technique is an alternative option for sulcus IOL implantation in absence of capsular support, allowing lens centration adjustment with no additional risks.

  9. Broadband Wide Angle Lens Implemented with Dielectric Metamaterials

    Directory of Open Access Journals (Sweden)

    Anthony Starr

    2011-08-01

    Full Text Available The Luneburg lens is a powerful imaging device, exhibiting aberration free focusing for parallel rays incident from any direction. However, its advantages are offset by a focal surface that is spherical and thus difficult to integrate with standard planar detector and emitter arrays. Using the recently developed technique of transformation optics, it is possible to transform the curved focal surface to a flat plane while maintaining the perfect focusing behavior of the Luneburg over a wide field of view. Here we apply these techniques to a lesser-known refractive Luneburg lens and implement the design with a metamaterial composed of a semi-crystalline distribution of holes drilled in a dielectric. In addition, we investigate the aberrations introduced by various approximations made in the implementation of the lens. The resulting design approach has improved mechanical strength with small aberrations and is ideally suited to implementation at infrared and visible wavelengths.

  10. Central vault in dry eye patients successfully wearing scleral lens.

    Science.gov (United States)

    Sonsino, Jeffrey; Mathe, Dora Sztipanovits

    2013-09-01

    Scleral contact lenses are used to treat symptoms of severe dry eyes. Procedures for fitting scleral lenses have been vague because of lack of standardized guidelines. This retrospective case series sought to establish average vault over central cornea in successful scleral lens wearers with dry eyes. Anterior segment optical coherence tomography was used to measure the distance between the posterior lens surface and cornea in 20 eyes of 12 consecutive patients successfully fit in the Vanderbilt Scleral Lens Clinic. Mean vault was 380 ± 110 μm. There was no correlation between vault and corneal curvature or vault and visual acuity. With a large SD in average vault, precision in central vault does not seem to be important in scleral contact lenses for successful fit for dry eyes.

  11. A compact combined ultrahigh vacuum scanning tunnelling microscope (UHV STM) and near-field optical microscope

    International Nuclear Information System (INIS)

    Woolley, R A J; Hayton, J A; Cavill, S; Ma, Jin; Beton, P H; Moriarty, P

    2008-01-01

    We have designed and constructed a hybrid scanning near-field optical microscope (SNOM)–scanning tunnelling microscope (STM) instrument which operates under ultrahigh vacuum (UHV) conditions. Indium tin oxide (ITO)-coated fibre-optic tips capable of high quality STM imaging and tunnelling spectroscopy are fabricated using a simple and reliable method which foregoes the electroless plating strategy previously employed by other groups. The fabrication process is reproducible, producing robust tips which may be exchanged under UHV conditions. We show that controlled contact with metal surfaces considerably enhances the STM imaging capabilities of fibre-optic tips. Light collection (from the cleaved back face of the ITO-coated fibre-optic tip) and optical alignment are facilitated by a simple two-lens arrangement where the in-vacuum collimation/collection lens may be adjusted using a slip-stick motor. A second in-air lens focuses the light (which emerges from the UHV system as a parallel beam) onto a cooled CCD spectrograph or photomultiplier tube. The application of the instrument to combined optical and electronic spectroscopy of Au and GaAs surfaces is discussed

  12. Design method of freeform light distribution lens for LED automotive headlamp based on DMD

    Science.gov (United States)

    Ma, Jianshe; Huang, Jianwei; Su, Ping; Cui, Yao

    2018-01-01

    We propose a new method to design freeform light distribution lens for light-emitting diode (LED) automotive headlamp based on digital micro mirror device (DMD). With the Parallel optical path architecture, the exit pupil of the illuminating system is set in infinity. Thus the principal incident rays of micro lens in DMD is parallel. DMD is made of high speed digital optical reflection array, the function of distribution lens is to distribute the emergent parallel rays from DMD and get a lighting pattern that fully comply with the national regulation GB 25991-2010.We use DLP 4500 to design the light distribution lens, mesh the target plane regulated by the national regulation GB 25991-2010 and correlate the mesh grids with the active mirror array of DLP4500. With the mapping relations and the refraction law, we can build the mathematics model and get the parameters of freeform light distribution lens. Then we import its parameter into the three-dimensional (3D) software CATIA to construct its 3D model. The ray tracing results using Tracepro demonstrate that the Illumination value of target plane is easily adjustable and fully comply with the requirement of the national regulation GB 25991-2010 by adjusting the exit brightness value of DMD. The theoretical optical efficiencies of the light distribution lens designed using this method could be up to 92% without any other auxiliary lens.

  13. Estimate of the dose received in crystalline lens by pediatric interventional cardiologists; Estimacion de la dosis recibida en cristalino por cardiologos intervencionistas pediatricos

    Energy Technology Data Exchange (ETDEWEB)

    Koren, C.; Alejo, L.; Serrada, A., E-mail: cristina.koren@salud.madrid.org [Hospital Universitario La Paz, Servicio de Radiofisica y Radioproteccion, Paseo de la Castellana 261, 28046 Madrid (Spain)

    2014-08-15

    The objective of this work is to estimate the maximum dose accumulated during one year in the crystalline lens of the pediatric interventional cardiologists that work in the Hospital Universitario La Paz. Optically Stimulated Luminescence Dosimeters (OSLDs) were used for to carry out this estimation, placed in the eyes of an anthropomorphic mannequin whose position in the room simulates the more habitual conditions of the clinical practice. Previously to the simulation, different tests to validate the used dosimetric system were realized, including those related with the stability, reproducibility and lector linearity, as well as the angular and energy dependence of the OSLDs. During the simulation the mannequin eyes were irradiated and were measured with OSLDs the rate of superficial equivalent dose in crystalline lens for the different qualities of beam habitually used, as much in fluoroscopy as in acquisition. With the obtained data during three years, corresponding to the fluoroscopy times and the acquisitions number of the interventional procedures carried out; as much therapeutic as diagnostic, and rate by measuring of obtained dose, has been considered the superficial equivalent dose and the equivalent dose at 3 mm deep accumulated in the crystalline lens of the pediatric interventional cardiologist with more work load of the Hospital, during the years 2011 and 2012. None of the obtained maximum values exceed the new dose annual limit in crystalline lens of 20 mSv, recommended by ICRP in April of 2011. (author)

  14. Optical Coherence Tomography Technology and Quality Improvement Methods for Optical Coherence Tomography Images of Skin: A Short Review

    OpenAIRE

    Adabi, Saba; Turani, Zahra; Fatemizadeh, Emad; Clayton, Anne; Nasiriavanaki, Mohammadreza

    2017-01-01

    Optical coherence tomography (OCT) delivers 3-dimensional images of tissue microstructures. Although OCT imaging offers a promising high-resolution method, OCT images experience some artifacts that lead to misapprehension of tissue structures. Speckle, intensity decay, and blurring are 3 major artifacts in OCT images. Speckle is due to the low coherent light source used in the configuration of OCT. Intensity decay is a deterioration of light with respect to depth, and blurring is the conseque...

  15. Effect of low gamma-ray doses and seeding rates on growth, yield and its components as well as seed quality of lentils (lens Culinaries, med.)

    International Nuclear Information System (INIS)

    Dprgham, E.A.

    1999-01-01

    To study the effect of low doses gamma-rays and seeding rates on growth, yield and its components as well as seed quality, two experiments were conducted during 1993/1994 and 1994/1995 seasons. Each experiment included treatments which were the combinations of three levels of seeding rates (45,60 and 75kg/fed.) and four doses of gamma-rays (15, 25,35 and 45(Gy). The effect of interaction between seeding rates and gamma doses on growth characters was not significant whereas there was a tendency for improvement of growth characters by increasing gamma doses up to 45 Gy. Different gamma doses caused marked increase for lintil's yield components except the number of seeds/plant while high seeding rates (60 and 75 Kg/fed) reduced significantly the number of pods/plant and number of seeds/plant. For yield, various gamma doses showed significant increase for seed straw yield as compared to the control. However, seeding rates of 60 and 75 kg/fed increased significantly seed and straw yield as compared with the seeding rate of 45 kg/fed (control)

  16. Bacterial and fungal biofilm formation on contact lenses and their susceptibility to lens care solutions

    Directory of Open Access Journals (Sweden)

    Siddharth Kackar

    2017-01-01

    Full Text Available Background: Microbial biofilm formation on contact lenses and lens storage cases may be a risk factor for contact lens-associated corneal infections. Various types of contact lens care solutions are used to reduce microbial growths on lenses. Objectives: The present study aimed at comparing the growths of biofilms on the different contact lenses and lens cases. The study also aimed at determining the effect of lens care solutions and bacteriophage on these biofilms. Materials and Methods: One type of hard lens and two types of soft lenses were used for the study. The organisms used were Staphylococcus aureus ATCC 25923, Pseudomonas aeruginosa ATCC 27853, Candida albicans ATCC 60193 and Escherichia coli ATCC 25922. Biofilm production was performed by modified O'Toole and Kolter method and effect of lens cleaning solutions and a crude coliphage on biofilms was also studied. Results were visualised using scanning electron microscopy and quantitated by colony counting method and spectrophotometric measurement of optical density (OD. Statistical analysis was done by SPSS 11.5, Kruskal–Wallis test and Chi-square test. Results: Soft lens cleaning solutions had a significant inhibitory effect (P = 0.020 on biofilm formation on soft lenses and also lens cases (P < 0.001. Soft lens cleaning solution 2 was more efficient than solution 1. However, no such inhibitory effect was observed with regard to hard lens cleaning solution, but for a significant reduction in the OD values (P < 0.001. There was no significant inhibitory effect by bacteriophages. Conclusion: This study showed the importance of selecting the appropriate lens cleaning solution to prevent biofilm production on contact lenses.

  17. Light Optics for Optical Stochastic Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Andorf, Matthew [NICADD, DeKalb; Lebedev, Valeri [Fermilab; Piot, Philippe [NICADD, DeKalb; Ruan, Jinhao [Fermilab

    2016-06-01

    In Optical Stochastic Cooling (OSC) radiation generated by a particle in a "pickup" undulator is amplified and transported to a downstream "kicker" undulator where it interacts with the same particle which radiated it. Fermilab plans to carry out both passive (no optical amplifier) and active (optical amplifier) tests of OSC at the Integrable Optics Test Accelerator (IOTA) currently in construction*. The performace of the optical system is analyzed with simulations in Synchrotron Radiation Workshop (SRW) accounting for the specific temporal and spectral properties of undulator radiation and being augmented to include dispersion of lens material.

  18. Adaptive optics microscopy enhances image quality in deep layers of CLARITY processed brains of YFP-H mice

    Science.gov (United States)

    Reinig, Marc R.; Novack, Samuel W.; Tao, Xiaodong; Ermini, Florian; Bentolila, Laurent A.; Roberts, Dustin G.; MacKenzie-Graham, Allan; Godshalk, S. E.; Raven, M. A.; Kubby, Joel

    2016-03-01

    Optical sectioning of biological tissues has become the method of choice for three-dimensional histological analyses. This is particularly important in the brain were neurons can extend processes over large distances and often whole brain tracing of neuronal processes is desirable. To allow deeper optical penetration, which in fixed tissue is limited by scattering and refractive index mismatching, tissue-clearing procedures such as CLARITY have been developed. CLARITY processed brains have a nearly uniform refractive index and three-dimensional reconstructions at cellular resolution have been published. However, when imaging in deep layers at submicron resolution some limitations caused by residual refractive index mismatching become apparent, as the resulting wavefront aberrations distort the microscopic image. The wavefront can be corrected with adaptive optics. Here, we investigate the wavefront aberrations at different depths in CLARITY processed mouse brains and demonstrate the potential of adaptive optics to enable higher resolution and a better signal-to-noise ratio. Our adaptive optics system achieves high-speed measurement and correction of the wavefront with an open-loop control using a wave front sensor and a deformable mirror. Using adaptive optics enhanced microscopy, we demonstrate improved image quality wavefront, point spread function, and signal to noise in the cortex of YFP-H mice.

  19. Contact Lens Wear at Altitude: Subcontact Lens Bubble Formation

    Science.gov (United States)

    1987-11-01

    incidence of (PMMA) lenses . Reported here are the results of contact lens subcontact lens bubble formation under scleral lenses at bubble studies with soft...vision from formation of large bubbles greater than 6,096 m (20,000 It). With soft contact lenses , bubble under their contact lenses . They also found...always located at the limbus and were without sequela to vision or corneal epithelial integrity. scleral lenses used by Jaeckle were permeable to gases

  20. Straylight Measurements in Contact Lens Wear

    NARCIS (Netherlands)

    van der Meulen, Ivanka J. E.; Engelbrecht, Leonore A.; van Vliet, Johannes M. J.; Lapid-Gortzak, Ruth; Nieuwendaal, Carla P.; Mourits, Maarten P.; Schlingemann, Reinier O.; van den Berg, Thomas J. T. P.

    2010-01-01

    Purpose: (1) To quantify the effect of contact lens wear on straylight in rigid and soft contact lens wearers and (2) to relate findings to morphological changes and subjective complaints. Methods: Straylight was measured using the Oculus C-Quant during contact lens wear and after contact lens

  1. A lab-on-phone instrument with varifocal microscope via a liquid-actuated aspheric lens (LAL.

    Directory of Open Access Journals (Sweden)

    Yiin-Kuen Fuh

    Full Text Available In this paper, we introduce a novel concept of liquid-actuated aspheric lens (LAL with a built-in aspheric polydimethylsiloxane lens (APL to enable the design of compact optical systems with varifocal microscopic imaging. The varifocal lens module consists of a sandwiched structures such as 3d printed syringe pump functionally serves as liquid controller. Other key components include two acrylic cylinders, a rigid separator, a APL/membrane composite (APLMC embedded PDMS membrane. In functional operation, the fluidic controller was driven to control the pressure difference and ALPMC deformation. The focal length can be changed through the pressure difference. This is achieved by the adjustment of volume change of injected liquid such that a widely tunable focal length. The proposed LAL can transform to 3 modes: microscopic mode (APLMC only, convex-concave mode and biconcave mode. It is noticeable that LAL in the operation of microscopic mode is tunable in focus via the actuation of APLMC (focal length is from 4.3 to 2.3 mm and magnification 50X and can rival the images quality of commercial microscopes. A new lab-on-phone device is economically feasible and functionally versatile to offer a great potential in the point of care applications.

  2. A simple but precise method for quantitative measurement of the quality of the laser focus in a scanning optical microscope.

    Science.gov (United States)

    Trägårdh, J; Macrae, K; Travis, C; Amor, R; Norris, G; Wilson, S H; Oppo, G-L; McConnell, G

    2015-07-01

    We report a method for characterizing the focussing laser beam exiting the objective in a laser scanning microscope. This method provides the size of the optical focus, the divergence of the beam, the ellipticity and the astigmatism. We use a microscopic-scale knife edge in the form of a simple transmission electron microscopy grid attached to a glass microscope slide, and a light-collecting optical fibre and photodiode underneath the specimen. By scanning the laser spot from a reflective to a transmitting part of the grid, a beam profile in the form of an error function can be obtained and by repeating this with the knife edge at different axial positions relative to the beam waist, the divergence and astigmatism of the postobjective laser beam can be obtained. The measured divergence can be used to quantify how much of the full numerical aperture of the lens is used in practice. We present data of the beam radius, beam divergence, ellipticity and astigmatism obtained with low (0.15, 0.7) and high (1.3) numerical aperture lenses and lasers commonly used in confocal and multiphoton laser scanning microscopy. Our knife-edge method has several advantages over alternative knife-edge methods used in microscopy including that the knife edge is easy to prepare, that the beam can be characterized also directly under a cover slip, as necessary to reduce spherical aberrations for objectives designed to be used with a cover slip, and it is suitable for use with commercial laser scanning microscopes where access to the laser beam can be limited. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.

  3. Glass molding of 3mm diameter aspheric plano-convex lens

    Science.gov (United States)

    Sung, Hayeong; Hue, Myung sang; Lee, Giljae; Ryu, Geunman; Kim, Dongguk; Yang, Suncheol

    2017-10-01

    The many industries and research fields have demands for small scale optical systems. To satisfy the demands, many studies are conducted and the miniaturization technologies have been developed. The optical lens is directly related to the optical systems and a key component for the miniaturization. So the aspheric surface which can replace multispherical lenses is applied to the optical lens. And fabrication methods to reduce the diameter of the lens have been developed. The glass molding pressing (GMP) process is an attractive method to fabricate aspheric lens among the lens manufacturing processes. Because the GMP process has advantages of productivity, repeatability and so on. In this study, a 3 mm diameter aspheric plano-convex lens was fabricated using the GMP process. The GMP process was divided into heating, pressing, annealing and cooling. And the process was conducted using a commercial glass molding machine. Mold tools consist of an upper and a lower mold insert, an inner and an outer guide. The aspheric and the flat surfaces of the mold inserts were coated with ta-C to prevent the sticking of the glass to the mold. The surfaces of molded lens were measured by white interferometry and surface profilometer. The height and the diameter were measured using optical microscopy. As results, the aspheric surface of the lens was 5.1187 nm in Ra and 0.242 um in Pt. And the flat surface was 2.6697 nm in Ra and 0.13 um in Pt. The height and the diameter were 1.935 mm and 3.002 mm respectively.

  4. Scientific performance assessments through a gender lens

    DEFF Research Database (Denmark)

    Nielsen, Mathias Wullum

    2018-01-01

    The focus on excellence and quality assurance in the academy has spawned a signifi cant increase in the use of bibliometric measures in performance assessments of individual researchers. This article investigates the organizational consequences of this development through a gender lens. Based....... They adhere to the prevailing ethos of the academic meritocracy by standardizing the criteria for organizational advancement and ensuring transparency and accountability in the selection process. While bibliometric tools in this sense may lead to the recruitment of scientists with a strong CV and track record...

  5. Contact Lens Related Corneal Ulcer

    OpenAIRE

    Loh, KY; Agarwal, P

    2010-01-01

    A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are: overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. Th...

  6. Design, tolerancing, and experimental characterization of dynamic freeform optical systems

    Science.gov (United States)

    Shultz, Jason Allen

    Although freeform concepts have been considered for many decades, new fabrication capabilities have enabled new classes of optical components and sparked greatly increased interest in freeform optics. Generally defined as surfaces without rotational symmetry, freeform optics enable complex phase variations due to their asymmetry. One approach for freeform optics utilizes multiple freeform surfaces in close proximity. Light transmitted through these surfaces results in a composite wavefront, which is then dynamically changed through controlled relative motions of the freeform surfaces, thereby dynamically changing the overall optical function of the system. These 'dynamic freeform optics' offer advantages such as design miniaturization, decreased manufacturing costs, and optical design flexibility. Examples include the varifocal Alvarez lens and a variable diameter Gaussian to flat-top beam shaper. In these cases the output function is varied through relative lateral shifts. The analytical design procedures for these examples have been well documented in previous work. However, previous cases possess inherent design constraints. For example, the classic Alvarez lens has no optical power when the lateral shift is zero, and both examples are limited to rotationally symmetric output functions and lateral shifts along a single axis. A primary objective of this dissertation is to expand design procedures to overcome these constraints for creation of additional novel dynamic freeform optical systems. The optical performance of several example systems is characterized through experimental testing of diamond-machined freeform elements. Furthermore, as the advantages offered by freeform systems are realized, there remain unknowns regarding performance sensitivity to several potential errors such as opto-mechanical alignment, surface form accuracy, and surface finish quality. To this end, this dissertation also includes individual tolerance analyses on each of these error

  7. Bmp4 from the Optic Vesicle Specifies Murine Retina Formation

    OpenAIRE

    Huang, Jie; Liu, Ying; Oltean, Alina; Beebe, David C.

    2015-01-01

    Previous studies of mouse embryos concluded that after the optic vesicle evaginates from the ventral forebrain and contacts the surface ectoderm, signals from the ectoderm specify the distal region of the optic vesicle to become retina and signals from the optic vesicle induce the lens. Germline deletion of Bmp4 resulted in failure of lens formation. We performed conditional deletion of Bmp4 from the optic vesicle to test the function of Bmp4 in murine eye development. The optic vesicle evagi...

  8. LENS - the Low-Energy Neutrino Spectrometer

    International Nuclear Information System (INIS)

    Hahn, Richard L.

    2004-01-01

    Despite the recent successes of SNO and KamLAND, the only detectors sensitive to <1 MeV-neutrinos have been the radiochemical chlorine and gallium solar neutrino experiments. LENS is being developed to measure in real time the charge-current fluxes and energy spectra of the lowest energy solar neutrinos, from the pp and 7Be branches (91% and 7% of solar neutrinos). The detector medium will be a metal-loaded liquid scintillator (M-LS), with indium as the metal, which serves as the target for neutrino capture in the LS. 115In has 95.71% natural abundance and a 114.2-keV neutrino-capture Q-value. Neutrino capture in 115In produces a β particle and preferentially feeds an excited state of 115Sn that de-excites by delayed emission of two γ rays. This triple-coincidence 'tag' in time and space in principle is a very powerful tool to discriminate neutrino-capture events from backgrounds. The International LENS R and D Collaboration is working to develop an In-LS neutrino detector, with special properties, such as high indium content, high light yield, high optical transparency, long-term chemical stability, and good signal-to-background ratio. Success in preparing the In-LS has been achieved via the synthesis of In-carboxylates that are soluble in pseudocumene LS (note that these methods may also be applicable to the preparation of Gd-LS for reactor antineutrino experiments). Testing of some prototype LENS In-LS detector modules has begun recently at the Gran Sasso Laboratory

  9. Gabor lens theory

    International Nuclear Information System (INIS)

    Irani, A.A.

    1978-01-01

    The principle of using the space charge of an electron cloud to focus ion beams was first proposed by Gabor. Electrons are to be confined radially by means of an axial magnetic field B/sub z/ and axially by means of externally applied electric fields E/sub z/. An ion beam of charge density n/sub i/ much less than n/sub e/, the electron charge density can then be focused by the radial electric field set up by the electron cloud. The case considered here is that of a hollow cylindrical conductor charged to a potential +V with grounded rings on either side to set up the axial E/sub z/ field. A solenoid wound around the central conductor supplies the B/sub z/ field. Theoretical calculations are carried out for n/sub e/ maximum as a function of B/sub z/ due to radial confinement and V due to axial confinement and the focal length of the Gabor Lens is calculated

  10. Effect of laser radiation wavelength and reepithelization process on optical quality of eye cornea after laser correction of vision

    Energy Technology Data Exchange (ETDEWEB)

    Kitai, M S; Semchishen, A V; Semchishen, V A [Institute on Laser and Information Technologies, Russian Academy of Sciences, Shatura, Moscow Region (Russian Federation)

    2015-10-31

    The optical quality of the eye cornea surface after performing the laser vision correction essentially depends on the characteristic roughness scale (CRS) of the ablated surface, which is mainly determined by the absorption coefficient of the cornea at the laser wavelength. Thus, in the case of using an excimer ArF laser (λ = 193 nm) the absorption coefficient is equal to 39000 cm{sup -1}, the darkening by the dissociation products takes place, and the depth of the roughness relief can be as large as 0.23 mm. Under irradiation with the Er : YAG laser (λ = 2940 nm) the clearing is observed due to the rupture of hydrogen bonds in water, and the relief depth exceeds 1 μm. It is shown that the process of reepithelization that occurs after performing the laser vision correction leads to the improvement of the optical quality of the cornea surface. (interaction of laser radiation with matter)

  11. A Comparison of Three Methods to Increase Scleral Contact Lens On-Eye Stability.

    Science.gov (United States)

    Ticak, Anita; Marsack, Jason D; Koenig, Darren E; Ravikumar, Ayeswarya; Shi, Yue; Nguyen, Lan Chi; Applegate, Raymond A

    2015-11-01

    To quantify on-eye rotational and translational stability of three scleral contact lens stabilization methods and to model the variation in visual acuity when these movements occur in a wavefront-guided correction for highly aberrated eyes. Three lens stabilization methods were integrated into the posterior periphery of a scleral contact lens designed at the Visual Optics Institute. For comparison, a lens with no stabilization method (rotationally symmetric posterior periphery) was designed. The lenses were manufactured and lens movements were quantified on 8 eyes as the average SD of the observed translations and rotations over 60 min of wear. In addition, the predicted changes in acuity for five eyes with keratoconus wearing a simulated wavefront-guided correction (full correction through the fifth order) were modeled using the measured movements. For each lens design, no significant differences in the translation and rotation were found between left and right eyes, and lenses behaved similarly on all subjects. All three designs with peripheral stability modifications exhibited no statistically significant differences in translation and rotation distributions of lens movement and were statistically more stable than the spherical lens in rotation. When the measured movements were used to simulate variation in visual performance, the 3 lenses with integrated stability methods showed a predicted average loss in acuity from the perfectly aligned condition of approximately 0.06 logMAR (3 letters), compared with the loss of over 0.14 logMAR (7 letters) for the lens with the spherical periphery. All three stabilization methods provided superior stability, as compared with the spherical lens design. Simulations of the optical and visual performance suggest that all three stabilization designs can provide desirable results when used in the delivery of a wavefront-guided correction for a highly aberrated eye.

  12. A Comparision of Three Methods to Increase Scleral Contact Lens On-eye Stability

    Science.gov (United States)

    Ticak, Anita; Marsack, Jason D.; Koenig, Darren E.; Ravikumar, Ayeswarya; Shi, Yue; Nguyen, Lan Chi; Applegate, Raymond A.

    2015-01-01

    Purpose To: 1) quantify on-eye rotational and translational stability of three scleral contact lens stabilization methods and 2) model the variation in visual acuity when these movements occur in a wavefront-guided correction for highly aberrated eyes. Methods Three lens stabilization methods were integrated into the posterior periphery of a scleral contact lens designed at the Visual Optics Institute. For comparison, a lens with no stabilization method (rotationally symmetric posterior periphery) was designed. The lenses were manufactured and lens movements were quantified on eight eyes as the average standard deviation of the observed translations and rotations over 60 minutes of wear. In addition, the predicted changes in acuity for 5 eyes with keratoconus wearing a simulated wavefront-guided correction (full correction through the fifth order) were modeled using the measured movements. Results For each lens design, no significant differences in the translation and rotation were found between left and right eyes, and lenses behaved similarly on all subjects. All three designs with peripheral stability modifications exhibited no statistically significant differences in translation and rotation distributions of lens movement and were statistically more stable than the spherical lens in rotation. When the measured movements were used to simulate variation in visual performance, the three lenses with integrated stability methods showed a predicted average loss in acuity from the perfectly aligned condition of approximately 0.06 logMAR (3 letters), compared to the loss of over 0.14 logMAR (7 letters) for the lens with the spherical periphery. Conclusions All three stabilization methods provided superior stability, as compared to the spherical lens design. Simulations of the optical and visual performance suggest that all three stabilization designs can provide desirable results when utilized in the delivery of a wavefront-guided correction for a highly aberrated eye

  13. Comparison of Two Intraocular Lens Implantation Techniques in Pediatric Cataract Surgery in Terms of Postoperative Complications

    Directory of Open Access Journals (Sweden)

    Mustafa Erdoğan Cicik

    2018-03-01

    Full Text Available Background: Pediatric cataract surgery differs substantially from adult cataract surgery. Numerous studies have focused on reducing the development of postoperative complications. Aims: To compare two intraocular lens implantation techniques used in pediatric cataract surgery in terms of postoperative complications. Study Design: Case-control study. Methods: Patients who underwent pediatric cataract surgery and intraocular lens implantation between 2008 and 2016 were evaluated in this retrospective study. Patients aged 3-15 years with unilateral or bilateral cataract and without corneal pathology were included in the study. The patients were categorized into the following two groups: those who underwent posterior capsulorhexis and anterior vitrectomy using in-the-bag intraocular lens implantation (group 1 and those who underwent posterior capsulorhexis and intraocular lens implantation with the optic fixed behind the posterior capsulorhexis (group 2. Rates of postoperative visual axis opacification and complications (glaucoma, posterior synechiae, uveitic reaction, and intraocular lens decentration were evaluated in these groups. The implanted intraocular lenses were either monoblock (AcrySof SN60AT intraocular lens, triple-piece (AcrySof MA60BM intraocular lens foldable hydrophobic acrylic lenses, or multifocal lenses (AcrySof IQ ReSTOR. Results: This retrospective study included 52 eyes of 37 patients. Group 1 comprised 26 eyes of 20 patients and group 2 comprised 26 eyes of 17 patients. During the follow-up, visual axis opacification was observed in two patients in group 1 but no patients in group 2. Regarding postoperative complications, there was no uveitic reaction, posterior synechiae, or intraocular lens decentration in either group. There was no significant difference between the groups in terms of the postoperative complications (p>0.05. Conclusion: There was no significant difference between in-the-bag intraocular lens implantation

  14. Influence of Overnight Orthokeratology on Corneal Surface Shape and Optical Quality

    Directory of Open Access Journals (Sweden)

    Yuan Sun

    2017-01-01

    Full Text Available Purpose. To investigate the changes of corneal surface shape and optical quality during orthokeratology. Methods. 49 eyes of 26 patients (10.63 ± 2.02 years old who underwent overnight orthokeratology for myopia were prospectively examined. The corneal surface shape parameters, including surface regularity index (SRI and surface asymmetry index (SAI, were attained with an OPD-III SCAN. The higher-order aberrations and higher-order Strehl ratios were calculated under a 3 mm pupil diameter before orthokeratology, 1 month, 3 months, and 6 months after orthokeratology. A P value of less than 0.05 was statistically significant. Results. Months after orthokeratology, SRI and SAI were both showing a significant increase in comparison with those before orthokeratology (P<0.001. After orthokeratology, for a 3 mm pupil, the higher-order Strehl ratio presented a reduction of 0.217 μm (P<0.001, and the higher-order aberration root mean square (HOA RMS showed a mean increase of 0.100 μm (P<0.001. There were significant increases in spherical aberration (P<0.001 and coma (P=0.044 after orthokeratology. Trefoil showed a slight reduction at month 6 after orthokeratology, but there was no statistical significance (P=0.722. Conclusion. Overnight orthokeratology for a correction of myopia resulted in a significant improvement in refractive error but increased corneal irregularity and ocular higher-order aberrations, especially in spherical aberration.

  15. Automating quality assurance of digital linear accelerators using a radioluminescent phosphor coated phantom and optical imaging.

    Science.gov (United States)

    Jenkins, Cesare H; Naczynski, Dominik J; Yu, Shu-Jung S; Yang, Yong; Xing, Lei

    2016-09-07

    Performing mechanical and geometric quality assurance (QA) tests for medical linear accelerators (LINAC) is a predominantly manual process that consumes significant time and resources. In order to alleviate this burden this study proposes a novel strategy to automate the process of performing these tests. The autonomous QA system consists of three parts: (1) a customized phantom coated with radioluminescent material; (2) an optical imaging system capable of visualizing the incidence of the radiation beam, light field or lasers on the phantom; and (3) software to process the captured signals. The radioluminescent phantom, which enables visualization of the radiation beam on the same surface as the light field and lasers, is placed on the couch and imaged while a predefined treatment plan is delivered from the LINAC. The captured images are then processed to self-calibrate the system and perform measurements for evaluating light field/radiation coincidence, jaw position indicators, cross-hair centering, treatment couch position indicators and localizing laser alignment. System accuracy is probed by intentionally introducing errors and by comparing with current clinical methods. The accuracy of self-calibration is evaluated by examining measurement repeatability under fixed and variable phantom setups. The integrated system was able to automatically collect, analyze and report the results for the mechanical alignment tests specified by TG-142. The average difference between introduced and measured errors was 0.13 mm. The system was shown to be consistent with current techniques. Measurement variability increased slightly from 0.1 mm to 0.2 mm when the phantom setup was varied, but no significant difference in the mean measurement value was detected. Total measurement time was less than 10 minutes for all tests as a result of automation. The system's unique features of a phosphor-coated phantom and fully automated, operator independent self-calibration offer the

  16. Design of Novel Compound Fresnel Lens for High-Performance Photovoltaic Concentrator

    Directory of Open Access Journals (Sweden)

    Lei Jing

    2012-01-01

    Full Text Available We present a new design of compound Fresnel-R concentrator which is composed of two lenses: a primary lens (Fresnel lens that works by total internal reflection at outer sawteeth but refraction at inner sawteeth, and a ringed secondary lens that works by refraction. In contrast to previous Fresnel lens concentrators, this design increases the acceptance angle, improves the irradiance uniformity on the solar cell, and reduces the aspect ratio significantly. Meanwhile several sawteeth of the primary Fresnel lens can correspond to a same ring of secondary lens, which will efficiently lower the complexity of designing and manufacturing. Moreover, in order to reduce the influence of manufacturing tolerances and to increase the optical efficiency further, the central part of the bottom of the secondary lens which directly adhered to the solar cell is designed as a cone-shaped prism to collect the sunlight that does not reach the solar cell. Finally, we provide simulations and analyses of the design method an optical efficiency more than 80% and an aspect ratio smaller than 0.5 can be achieved.

  17. Scleral lens influence on corneal curvature and pachymetry in keratoconus patients.

    Science.gov (United States)

    Soeters, Nienke; Visser, Esther Simone; Imhof, Saskia M; Tahzib, Nayyirih G

    2015-08-01

    To investigate the influence of full scleral lenses on corneal curvature and pachymetry in keratoconus patients. In this intervention study, 20 eyes of 14 patients were measured by Scheimpflug imaging (Pentacam HR, Oculus) at two time points: directly and ≥1 week after scleral lens removal. Steep, flat and maximal keratometry (K(steep), K(flat) and K(max)) and optical pachymetry were analyzed. A generalized estimating equation analysis was performed to correct for paired eyes. Directly after scleral lens removal, all three curvature parameters were significantly flatter compared to ≥1 week after scleral lens removal. Average K(steep) was 0.7 diopter (D) lower (Pscleral lens removal, average optical pachymetry was ±2.5% higher (Pscleral lens removal. Although scleral lenses do not mechanically touch the cornea, curvature and pachymetry seem to be influenced by scleral lens wear in keratoconus patients. The duration of these changes remain unclear. Copyright © 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  18. Opto-mechatronics issues in solid immersion lens based near-field recording

    Science.gov (United States)

    Park, No-Cheol; Yoon, Yong-Joong; Lee, Yong-Hyun; Kim, Joong-Gon; Kim, Wan-Chin; Choi, Hyun; Lim, Seungho; Yang, Tae-Man; Choi, Moon-Ho; Yang, Hyunseok; Rhim, Yoon-Chul; Park, Young-Pil

    2007-06-01

    We analyzed the effects of an external shock on a collision problem in a solid immersion lens (SIL) based near-field recording (NFR) through a shock response analysis and proposed a possible solution to this problem with adopting a protector and safety mode. With this proposed method the collision between SIL and media can be avoided. We showed possible solution for contamination problem in SIL based NFR through a numerical air flow analysis. We also introduced possible solid immersion lens designs to increase the fabrication and assembly tolerances of an optical head with replicated lens. Potentially, these research results could advance NFR technology for commercial product.

  19. Circuit design for the retina-like image sensor based on space-variant lens array

    Science.gov (United States)

    Gao, Hongxun; Hao, Qun; Jin, Xuefeng; Cao, Jie; Liu, Yue; Song, Yong; Fan, Fan

    2013-12-01

    Retina-like image sensor is based on the non-uniformity of the human eyes and the log-polar coordinate theory. It has advantages of high-quality data compression and redundant information elimination. However, retina-like image sensors based on the CMOS craft have drawbacks such as high cost, low sensitivity and signal outputting efficiency and updating inconvenience. Therefore, this paper proposes a retina-like image sensor based on space-variant lens array, focusing on the circuit design to provide circuit support to the whole system. The circuit includes the following parts: (1) A photo-detector array with a lens array to convert optical signals to electrical signals; (2) a strobe circuit for time-gating of the pixels and parallel paths for high-speed transmission of the data; (3) a high-precision digital potentiometer for the I-V conversion, ratio normalization and sensitivity adjustment, a programmable gain amplifier for automatic generation control(AGC), and a A/D converter for the A/D conversion in every path; (4) the digital data is displayed on LCD and stored temporarily in DDR2 SDRAM; (5) a USB port to transfer the data to PC; (6) the whole system is controlled by FPGA. This circuit has advantages as lower cost, larger pixels, updating convenience and higher signal outputting efficiency. Experiments have proved that the grayscale output of every pixel basically matches the target and a non-uniform image of the target is ideally achieved in real time. The circuit can provide adequate technical support to retina-like image sensors based on space-variant lens array.

  20. Fabrication of polycrystalline diamond refractive X-ray lens by femtosecond laser processing

    Energy Technology Data Exchange (ETDEWEB)

    Kononenko, T.V.; Ralchenko, V.G.; Ashkinazi, E.E.; Konov, V.I. [General Physics Institute of Russian Academy of Sciences, Moscow (Russian Federation); National Research Nuclear University ' ' MEPhI' ' , Moscow (Russian Federation); Polikarpov, M.; Ershov, P. [Immanuel Kant Baltic Federal University, Functional Nanomaterials, Kaliningrad (Russian Federation); Kuznetsov, S.; Yunkin, V. [Institute of Microelectronics Technology RAS, Chernogolovka, Moscow region (Russian Federation); Snigireva, I. [European Synchrotron Radiation Facility, Grenoble (France)

    2016-03-15

    X-ray planar compound refractive lenses were fabricated from a polycrystalline diamond plate grown by chemical vapor deposition, by precise through cutting with femtosecond laser pulses. The lens geometry and the surface morphology were investigated with optical and scanning electron microscopy, while the material structure modification was analyzed by Raman spectroscopy. The results of the preliminary lens test at 9.25-keV X-rays are presented. (orig.)

  1. Fabrication of polycrystalline diamond refractive X-ray lens by femtosecond laser processing

    International Nuclear Information System (INIS)

    Kononenko, T.V.; Ralchenko, V.G.; Ashkinazi, E.E.; Konov, V.I.; Polikarpov, M.; Ershov, P.; Kuznetsov, S.; Yunkin, V.; Snigireva, I.

    2016-01-01

    X-ray planar compound refractive lenses were fabricated from a polycrystalline diamond plate grown by chemical vapor deposition, by precise through cutting with femtosecond laser pulses. The lens geometry and the surface morphology were investigated with optical and scanning electron microscopy, while the material structure modification was analyzed by Raman spectroscopy. The results of the preliminary lens test at 9.25-keV X-rays are presented. (orig.)

  2. Simulating and optimizing compound refractive lens-based X-ray microscopes

    DEFF Research Database (Denmark)

    Simons, Hugh; Ahl, Sonja Rosenlund; Poulsen, Henning Friis

    2017-01-01

    A comprehensive optical description of compound refractive lenses (CRLs) in condensing and full-field X-ray microscopy applications is presented. The formalism extends ray-transfer matrix analysis by accounting for X-ray attenuation by the lens material. Closed analytical expressions for critical......-lens limit. This limit may be satisfied by a range of CRL geometries, suggesting alternative approaches to improving the resolution and efficiency of CRLs and X-ray microscopes....

  3. Technical assessment of Navitar Zoom 6000 optic and Sony HDC-X310 camera for MEMS presentations and training.

    Energy Technology Data Exchange (ETDEWEB)

    Diegert, Carl F.

    2006-02-01

    This report evaluates a newly-available, high-definition, video camera coupled with a zoom optical system for microscopic imaging of micro-electro-mechanical systems. We did this work to support configuration of three document-camera-like stations as part of an installation in a new Microsystems building at Sandia National Laboratories. The video display walls to be installed as part of these three presentation and training stations are of extraordinary resolution and quality. The new availability of a reasonably-priced, cinema-quality, high-definition video camera offers the prospect of filling these displays with full-motion imaging of Sandia's microscopic products at a quality substantially beyond the quality of typical video microscopes. Simple and robust operation of the microscope stations will allow the extraordinary-quality imaging to contribute to Sandia's day-to-day research and training operations. This report illustrates the disappointing image quality from a camera/lens system comprised of a Sony HDC-X310 high-definition video camera coupled to a Navitar Zoom 6000 lens. We determined that this Sony camera is capable of substantially more image quality than the Navitar optic can deliver. We identified an optical doubler lens from Navitar as the component of their optical system that accounts for a substantial part of the image quality problem. While work continues to incrementally improve performance of the Navitar system, we are also evaluating optical systems from other vendors to couple to this Sony camera.

  4. Review of the Experimental Background and Implementation of Computational Models of the Ocular Lens Microcirculation.

    Science.gov (United States)

    Wu, Ho-Ting D; Donaldson, Paul J; Vaghefi, Ehsan

    2016-01-01

    Our sense of vision is critically dependent on the clarity of the crystalline lens. The most common cause of transparency loss in the lens is age-related nuclear cataract, which is due to accumulative oxidative damage to this tissue. Since the ocular lens is an avascular tissue, it has to maintain its physiological homeostasis and antioxidant levels using a system of water microcirculation. This system has been experimentally imaged in animal lenses using different modalities. Based on these data, computational models have been developed to predict the properties of this system in human lenses and its changes due to aging. Although successful in predicting many aspects of lens fluid dynamics, at least in animal models, these in-silica models still need further improvement to become more accurate and representative of human ocular lens. We have been working on gathering experimental data and simultaneously developing computational models of lens microcirculation for the past decade. This review chronologically looks at the development of data-driven computational foundations of lens microcirculation model, its current state, and future advancement directions. A comprehensive model of lens fluid dynamics is essential to understand the physiological optics of this tissue and ultimately the underlying mechanisms of cataract onset and progression.

  5. Optimising RGP lens fitting in normal eyes using 3D topographic data.

    Science.gov (United States)

    van der Worp, Eef; de Brabander, John; Lubberman, Ben; Marin, Gildas; Hendrikse, Fred

    2002-06-01

    To analyse, retrospectively, the effect of fitting characteristics on comfort of wear and the role that 3D topographic data can play in attaining an optimal lens fit with rigid gas permeable (RGP) contact lenses in normal eyes. Included were 60 normal myopic eyes (1.00-5.00 D) with astigmatism limited to 2.00 D. Lenses were ordered empirically, based on traditional fitting rules. The initial fit based on traditional computation was accepted in 40% of the eyes. To achieve an acceptable fit, 15% of the eyes needed an adaptation of the back optic zone radius, in 28% switching from a multicurve to an aspheric lens design was indicated and in 17% a non-rotational symmetric lens design was favoured. The reason for changing the lens parameters could in 88% be attributed to mid-peripheral differences between corneal shape as found with 3D corneal topography. Average comfort of wear improved statistically significantly (chi(2), P<0.05) from 5.2 initially to 7.7 after 3 months in the group with optimal lens fits, while comfort slightly decreased (not significant) in the group with sub-optimal fits. Switching to a non-rotational symmetric lens design, when indicated, improved comfort significantly (chi(2), P<0.05) from 5.0 to 7.3. In normal eyes, the measurement of corneal shape, especially in the mid-peripheral regions, is of importance to optimise RGP lens fit. Optimised lens fits increases comfort of wear.

  6. The relationship between the retinal image quality and the refractive index of defects arising in IOL: numerical analysis

    Science.gov (United States)

    Geniusz, Malwina

    2017-09-01

    The best treatment for cataract patients, which allows to restore clear vision is implanting an artificial intraocular lens (IOL). The image quality of the lens has a significant impact on the quality of patient's vision. After a long exposure the implant to aqueous environment some defects appear in the artificial lenses. The defects generated in the IOL have different refractive indices. For example, glistening phenomenon is based on light scattering on the oval microvacuoles filled with an aqueous humor which refractive index value is about 1.34. Calcium deposits are another example of lens defects and they can be characterized by the refractive index 1.63. In the presented studies it was calculated how the difference between the refractive indices of the defect and the refractive index of the lens material affects the quality of image. The OpticStudio Professional program (from Radiant Zemax, LLC) was used for the construction of the numerical model of the eye with IOL and to calculate the characteristics of the retinal image. Retinal image quality was described in such characteristics as Point Spread Function (PSF) and the Optical Transfer Function with amplitude and phase. The results show a strong correlation between the refractive indices difference and retinal image quality.

  7. Study of Optical Models Regarding the Human Eye

    Directory of Open Access Journals (Sweden)

    Maryam Abolmasoomi

    2011-03-01

    Full Text Available Introduction: Until now, many models have been presented for optical study of the human eye. In recent years, surgery on the anterior section of the eye (such as cataract and photo-refractive surgery has increased, so a study on the optics of the eye and evaluation of vision quality has become more important. Material and Methods: In this article, some of these models are considered. They include models with spherical and conic-section surfaces (for cornea and lens, simple models and new models with complex surfaces. Results: Evaluation of the optical models of the eye provides the possibility of enhancing the representation of human vision and also increasing the accuracy of surgery on the anterior section of the eye to enable higher quality vision.

  8. Accuracy of fish-eye lens models.

    Science.gov (United States)

    Hughes, Ciarán; Denny, Patrick; Jones, Edward; Glavin, Martin

    2010-06-10

    The majority of computer vision applications assumes that the camera adheres to the pinhole camera model. However, most optical systems will introduce undesirable effects. By far, the most evident of these effects is radial lensing, which is particularly noticeable in fish-eye camera systems, where the effect is relatively extreme. Several authors have developed models of fish-eye lenses that can be used to describe the fish-eye displacement. Our aim is to evaluate the accuracy of several of these models. Thus, we present a method by which the lens curve of a fish-eye camera can be extracted using well-founded assumptions and perspective methods. Several of the models from the literature are examined against this empirically derived curve.

  9. DotLens smartphone microscopy for biological and biomedical applications (Conference Presentation)

    Science.gov (United States)

    Sung, Yu-Lung; Zhao, Fusheng; Shih, Wei-Chuan

    2017-02-01

    Recent advances in inkjet-printed optics have created a new class of lens fabrication technique. Lenses with a tunable geometry, magnification, and focal length can be fabricated by dispensing controlled amounts of liquid polymer onto a heated surface. This fabrication technique is highly cost-effective, and can achieve optically smooth surface finish. Dubbed DotLens, a single of which weighs less than 50 mg and occupies a volume less than 50 μL. DotLens can be attached onto any smartphone camera akin to a contact lens, and enable smartphones to obtain image resolution as fine as 1 µm. The surface curvature modifies the optical path of light to the image sensor, and enables the camera to focus as close as 2 mm. This enables microscopic imaging on a smartphone without any additional attachments, and has shown great potential in mobile point-of-care diagnostic systems, particularly for histology of tissue sections and cytology of blood cells. DotLens Smartphone Microscopy represents an innovative approach fundamentally different from other smartphone microscopes. In this paper, we describe the application and performance of DotLens smartphone microscopy in biological and biomedical research. In particular, we show recent results from images collected from pathology tissue slides with cancer features. In addition, we show performance in cytological analysis of blood smear. This tool has empowered Citizen Science investigators to collect microscopic images from various interesting objects.

  10. Investigation into photostability of soybean oils by thermal lens spectroscopy

    Science.gov (United States)

    Savi, E. L.; Malacarne, L. C.; Baesso, M. L.; Pintro, P. T. M.; Croge, C.; Shen, J.; Astrath, N. G. C.

    2015-06-01

    Assessment of photochemical stability is essential for evaluating quality and the shelf life of vegetable oils, which are very important aspects of marketing and human health. Most of conventional methods used to investigate oxidative stability requires long time experimental procedures with high consumption of chemical inputs for the preparation or extraction of sample compounds. In this work we propose a time-resolved thermal lens method to analyze photostability of edible oils by quantitative measurement of photoreaction cross-section. An all-numerical routine is employed to solve a complex theoretical problem involving photochemical reaction, thermal lens effect, and mass diffusion during local laser excitation. The photostability of pure oil and oils with natural and synthetic antioxidants is investigated. The thermal lens results are compared with those obtained by conventional methods, and a complete set of physical properties of the samples is presented.

  11. Investigation into photostability of soybean oils by thermal lens spectroscopy.

    Science.gov (United States)

    Savi, E L; Malacarne, L C; Baesso, M L; Pintro, P T M; Croge, C; Shen, J; Astrath, N G C

    2015-06-15

    Assessment of photochemical stability is essential for evaluating quality and the shelf life of vegetable oils, which are very important aspects of marketing and human health. Most of conventional methods used to investigate oxidative stability requires long time experimental procedures with high consumption of chemical inputs for the preparation or extraction of sample compounds. In this work we propose a time-resolved thermal lens method to analyze photostability of edible oils by quantitative measurement of photoreaction cross-section. An all-numerical routine is employed to solve a complex theoretical problem involving photochemical reaction, thermal lens effect, and mass diffusion during local laser excitation. The photostability of pure oil and oils with natural and synthetic antioxidants is investigated. The thermal lens results are compared with those obtained by conventional methods, and a complete set of physical properties of the samples is presented. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Salvaging an Abused Lens or How a 4½ inch Brashear lens came unglued before I did!

    Science.gov (United States)

    Koester, Jack

    The author's newly-acquired Brashear telescope has a "fogged lens" that was stuck in its cell. After getting advice from several ATS members, the author visits Richard A. Buchroeder, the professional optical designer, who heats the mirror and cell in order to soften the binding substance by floating the cell in a pot filled with heated cooking oil. The process worked, and the two lenses were removed.

  13. [Contact lens care and maintenance].

    Science.gov (United States)

    Bloise, L

    2017-04-01

    All contact lenses with replacement schedules longer than daily must be maintained. At each step of their use, the lenses may be contaminated. Contact lens solutions perform the essential functions of cleaning, decontaminating and preserving the lenses to prevent infectious problems and improve wearing comfort. Contact lens contamination essentially comes from hands, cleaning solutions, cases, water and the environment. The pathogenic microorganisms are mainly Gram-negative bacteria, fungi and amoebae. Contact lens deposits may or may not have an organic origin. Their presence increases the risk of infection because they serve as a nutrient matrix for microbes, and they are responsible for wearing discomfort. Contact lens solutions differ in their composition, their mechanism of action and the concentration of the various agents. To prescribe the best lens care system to each wearer and for each material, it is necessary to be very familiar with them. Maintenance is the main cause of discomfort with contact lenses, either through improper use, solution-material incompatibility, or a reaction of the wearer to the components. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  14. Advanced Holographic Phase Nulls Suitable for EUV Quality Optical Testing, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — A number of future space sciences missions require optical surfaces that are accurate to nanometer and sub-nanometer levels. These applications include large...

  15. Advanced Holographic Phase Nulls Suitable for EUV Quality Optical Testing Project

    Data.gov (United States)

    National Aeronautics and Space Administration — A number of future space sciences missions require optical surfaces that are accurate to nanometer and sub-nanometer levels. These applications include large...

  16. Optical Magnification Should Be Mandatory for Microsurgery: Scientific Basis and Clinical Data Contributing to Quality Assurance

    OpenAIRE

    Harald Schoeffl; Davide Lazzeri; Richard Schnelzer; Stefan M. Froschauer; Georg M. Huemer

    2013-01-01

    Background Microsurgical techniques are considered standard procedures in reconstructive surgery. Although microsurgery by itself is defined as surgery aided by optical magnification, there are no guidelines for determining in which clinical situations a microscope or loupe should be used. Therefore, we conducted standardized experiments to objectively assess the impact of optical magnification in microsurgery. Methods Sixteen participants of microsurgical training courses had to complete 2 s...

  17. Automated Fresnel lens tester system

    Energy Technology Data Exchange (ETDEWEB)

    Phipps, G.S.

    1981-07-01

    An automated data collection system controlled by a desktop computer has been developed for testing Fresnel concentrators (lenses) intended for solar energy applications. The system maps the two-dimensional irradiance pattern (image) formed in a plane parallel to the lens, whereas the lens and detector assembly track the sun. A point detector silicon diode (0.5-mm-dia active area) measures the irradiance at each point of an operator-defined rectilinear grid of data positions. Comparison with a second detector measuring solar insolation levels results in solar concentration ratios over the image plane. Summation of image plane energies allows calculation of lens efficiencies for various solar cell sizes. Various graphical plots of concentration ratio data help to visualize energy distribution patterns.

  18. Compliance among soft contact lens wearers.

    Science.gov (United States)

    Kuzman, Tomislav; Kutija, Marija Barisić; Masnec, Sanja; Jandroković, Sonja; Mrazovac, Danijela; Jurisić, Darija; Skegro, Ivan; Kalauz, Miro; Kordić, Rajko

    2014-12-01

    Contact lens compliance is proven to be crucial for preventing lens wear-related complications because of the interdependence of the steps in lens care regime and their influence on lens system microbial contamination. Awareness of the patients' lens handling compliance as well as correct recognition of non-compliant behaviours is the basis for creating more targeted strategies for patient education. The aim of this study was to investigate compliance among soft contact lens (SCL) wearers in different aspects of lens care handling and wearing habits. In our research 50 asymptomatic lens wearers filled out a questionnaire containing demographic data, lens type, hygiene and wearing habits, lenses and lens care system replacement schedule and self-evaluation of contact lens handling hygiene. We established criteria of compliance according to available manufacturer's recommendations, prior literature and our clinical experience. Only 2 (4%) of patients were fully compliant SCL wearers. The most common non-compliant behaviours were insufficient lens solution soaking time (62%), followed by failure to daily exchange lens case solution and showering while wearing lenses. 44% of patients reported storing lenses in saline solution. Mean lens storage case replacement was 3.6 months, with up to 78% patients replacing lens case at least once in 3 months. Average grade in self evaluating level of compliance was very good (4 +/- 0.78) (from 1-poor level of hygiene to 5-great level of hygiene). Lens wearers who reported excessive daily lens wear and more than 10 years of lens wearing experience were also found to be less compliant with other lens system care procedures. (t = -2.99, df=47, p lens system maintenance steps. Most common non-compliant behaviours were the ones that are crucial for maintaining lens sterility and preventing infection. Despite the low objective compliance rate, self grading was relatively high. Therefore, these results indicate the need for patient

  19. Effect of the defect on the focusing in a two-dimensional photonic-crystal-based flat lens

    International Nuclear Information System (INIS)

    Feng Zhifang; Wang Xiuguo; Li Zhiyuan; Zhang Daozhong

    2008-01-01

    We have investigated in detail the influence of defect on the focusing of electromagnetic waves in a two-dimensional photonic-crystal flat lens by using the finite-difference time-domain method. The result shows that many focusings can be observed at the symmetrical positions when a defect is introduced into the lens. Furthermore, the wave-guides in the lens can confine the transmission wave effectively and improve the quality of the focusing

  20. Optical models of the human eye.

    Science.gov (United States)

    Atchison, David A; Thibos, Larry N

    2016-03-01

    Optical models of the human eye have been used in visual science for purposes such as providing a framework for explaining optical phenomena in vision, for predicting how refraction and aberrations are affected by change in ocular biometry and as computational tools for exploring the limitations imposed on vision by the optical system of the eye. We address the issue of what is understood by optical model eyes, discussing the 'encyclopaedia' and 'toy train' approaches to modelling. An extensive list of purposes of models is provided. We discuss many of the theoretical types of optical models (also schematic eyes) of varying anatomical accuracy, including single, three and four refracting surface variants. We cover the models with lens structure in the form of nested shells and gradient index. Many optical eye models give accurate predictions only for small angles and small fields of view. If aberrations and image quality are important to consider, such 'paraxial' model eyes must be replaced by 'finite model' eyes incorporating features such as aspheric surfaces, tilts and decentrations, wavelength-dependent media and curved retinas. Many optical model eyes are population averages and must become adaptable to account for age, gender, ethnicity, refractive error and accommodation. They can also be customised for the individual when extensive ocular biometry and optical performance data are available. We consider which optical model should be used for a particular purpose, adhering to the principle that the best model is the simplest fit for the task. We provide a glimpse into the future of optical models of the human eye. This review is interwoven with historical developments, highlighting the important people who have contributed so richly to our understanding of visual optics. © 2016 The Authors. Clinical and Experimental Optometry © 2016 Optometry Australia.

  1. Cellulose nanocrystal and poly[di(ethylene glycol) adipate] blend for tunable lens

    Science.gov (United States)

    Ko, Hyun-U.; Kim, Hyun Chan; Li, Yaguang; Kim, Sang Youn; Kim, Jaehwan

    2016-04-01

    In these days, consumer electronics and medical device for optical diagnosis are minimalized and mobilized. The focusing part is one of crucial parts of optical diagnosis systems to reduce the size and weight. Thus, demand for tunable lens that change the focus itself is increased. To meet the demand, many tunable lens has been studied by utilizing smart materials that responded under mechanical, magnetic, optical, thermal, chemical, electrical or electrochemical stimuli. This paper reports a cellulose nanocrystal (CNC) and poly[di(ethylene glycol) adipate] (PDEGA) blend that is able to respond under electromechanical stimulus. The preparation of CNC/PDEGA and its characterization are illustrated and its actuation behavior is tested . Because the material has high dielectric constant and high reflection index, it is good candidate material for tunable lens.

  2. Acanthamoeba keratitis. Contact lens and noncontact lens characteristics.

    Science.gov (United States)

    Chynn, E W; Lopez, M A; Pavan-Langston, D; Talamo, J H

    1995-09-01

    To identify potential differences in time to diagnosis and final visual outcome between contact lens and noncontact lens users with Acanthamoeba keratitis. Prior studies have shown early diagnosis and therapy to be related to outcome but have not analyzed differences among patients with and without contact lenses. A retrospective analysis of 11 consecutive cases (involving 13 eyes) of Acanthamoeba keratitis diagnosed at one institution over a 3-year period. Mean time to diagnosis was significantly longer in noncontact lens users versus those who wore contact lenses (mean, 5.8 versus 3.3 weeks). Fifty percent of patients who did not wear contact lenses had a poor outcome (visual acuity worse than 20/40 or penetrating keratoplasty) versus 14% of patients who wore contact lenses. Diagnoses were made later in patients without contact lenses, and these patients had a worse visual outcome than those with Acanthamoeba keratitis who wore contact lenses. All patients with unresponsive microbial keratitis, even those without contact lens use, should be evaluated for Acanthamoeba.

  3. An XML file format for exchanging singlet lens specifications

    Science.gov (United States)

    Gay, Shawn C.; Gangadhara, Sanjay

    2015-10-01

    Zemax has developed an XML schema for the distribution of singlet lens specifications based on the ISO 10110 standard. In OpticStudio 15, this kind of XML data can be exported from the ISO Element Drawing analysis. The data file is then used in a feature that automates exchange of lens data between designer and manufacturer, the Cost Estimator. This Cost Estimator feature submits the XML data to various manufacturers to obtain cost estimates for prototype lens production. The workflow centered on the XML data exchange facilitates rapid cost estimate retrieval and eliminates the need for redundant manual data entry. The XML Schema Definition (XSD) for the XML format can be used with Microsoft developer tools to automatically create .NET classes to serialize and deserialize the singlet lens data to/from XML files. The format provides flexible unit specification for most parameters. Choosing XML as the basis for the file format has provided several benefits, such as the above mentioned automated serialization capabilities in .NET, a human-readable text-based format, and ready support for consumption by web services.

  4. Definition, aims, and implementation of GA(2) LEN Urticaria Centers of Reference and Excellence

    DEFF Research Database (Denmark)

    Maurer, M; Metz, M; Bindslev-Jensen, C

    2016-01-01

    BACKGROUND: GA²LEN, the Global Allergy and Asthma European Network, has recently launched a program for the development, interaction, and accreditation of centers of reference and excellence in special areas of allergy embedded in its overall quality management of allergy centers of excellence...... such as urticaria. AIMS: Here, we describe the aims, the requirements and deliverables, the application process, and the audit and accreditation protocol for GA²LEN UCAREs. RESULTS: The main aims of GA²LEN UCAREs are to provide excellence in urticaria management, to increase the knowledge of urticaria by research...... and education, and to promote the awareness of urticaria by advocacy activities. To become a certified GA²LEN UCARE, urticaria centers have to apply and fulfill 32 requirements, defined by specific deliverables that are assessed during an audit visit. DISCUSSION AND CONCLUSION: The GA²LEN UCARE program...

  5. Teleophthalmology with optical coherence tomography imaging in community optometry. Evaluation of a quality improvement for macular patients

    Directory of Open Access Journals (Sweden)

    Kelly SP

    2011-12-01

    Full Text Available Simon P Kelly1, Ian Wallwork2, David Haider1, Kashif Qureshi11Ophthalmology Department, Royal Bolton Hospital National Health Service Foundation Trust, Bolton, 2Wallwork Opticians, Salford, UKPurpose: To describe a quality improvement for referral of National Health Service patients with macular disorders from a community optometry setting in an urban area.Methods: Service evaluation of teleophthalmology consultation based on spectral domain optical coherence tomography images acquired by the community optometrist and transmitted to hospital eye services.Results: Fifty patients with suspected macular conditions were managed via telemedicine consultation over 1 year. Responses were provided by hospital eye service-based ophthalmologists to the community optometrist or patient within the next day in 48 cases (96% and in 34 (68% patients on the same day. In the consensus opinion of the optometrist and ophthalmologist, 33 (66% patients required further “face-to-face” medical examination and were triaged on clinical urgency. Seventeen cases (34% were managed in the community and are a potential cost improvement. Specialty trainees were supervised in telemedicine consultations.Conclusion: Innovation and quality improvement were demonstrated in both optometry to ophthalmology referrals and in primary optometric care by use of telemedicine with spectral domain optical coherence tomography images. E-referral of spectral domain optical coherence tomography images assists triage of macular patients and swifter care of urgent cases. Teleophthalmology is also, in the authors’ opinion, a tool to improve interdisciplinary professional working with community optometrists. Implications for progress are discussed.Keywords: telemedicine, teleophthalmology, innovation, community referral, optical coherence tomography, service evaluation

  6. Estimation of both optical and nonoptical surface water quality parameters using Landsat 8 OLI imagery and statistical techniques

    Science.gov (United States)

    Sharaf El Din, Essam; Zhang, Yun

    2017-10-01

    Traditional surface water quality assessment is costly, labor intensive, and time consuming; however, remote sensing has the potential to assess surface water quality because of its spatiotemporal consistency. Therefore, estimating concentrations of surface water quality parameters (SWQPs) from satellite imagery is essential. Remote sensing estimation of nonoptical SWQPs, such as chemical oxygen demand (COD), biochemical oxygen demand (BOD), and dissolved oxygen (DO), has not yet been performed because they are less likely to affect signals measured by satellite sensors. However, concentrations of nonoptical variables may be correlated with optical variables, such as turbidity and total suspended sediments, which do affect the reflected radiation. In this context, an indirect relationship between satellite multispectral data and COD, BOD, and DO can be assumed. Therefore, this research attempts to develop an integrated Landsat 8 band ratios and stepwise regression to estimate concentrations of both optical and nonoptical SWQPs. Compared with previous studies, a significant correlation between Landsat 8 surface reflectance and concentrations of SWQPs was achieved and the obtained coefficient of determination (R2)>0.85. These findings demonstrated the possibility of using our technique to develop models to estimate concentrations of SWQPs and to generate spatiotemporal maps of SWQPs from Landsat 8 imagery.

  7. The aquatic real-time monitoring network; in-situ optical sensors for monitoring the nation's water quality

    Science.gov (United States)

    Pellerin, Brian A.; Bergamaschi, Brian A.; Murdoch, Peter S.; Downing, Bryan D.; Saraceno, John Franco; Aiken, George R.; Striegl, Robert G.

    2011-01-01

    Floods, hurricanes, and longer-term changes in climate and land use can have profound effects on water quality due to shifts in hydrologic flow paths, water residence time, precipitation patterns, connectivity between rivers and uplands, and many other factors. In order to understand and respond to changes in hydrology and water quality, resource managers and policy makers have a need for accurate and early indicators, as well as the ability to assess possible mechanisms and likely outcomes. In-situ optical sensors-those making continuous measurements of constituents by absorbance or fluorescence properties in the environment at timescales of minutes to years-have a long history in oceanography for developing highly resolved concentrations and fluxes, but are not commonly used in freshwater systems. The United States Geological Survey (USGS) has developed the Aquatic Real-Time Monitoring Network, with high-resolution optical data collection for organic carbon, nutrients, and sediment in large coastal rivers, along with continuous measurements of discharge, water temperature, and dissolved inorganic carbon. The collecting of continuous water-quality data in the Nation?s waterways has revealed temporal trends and spatial patterns in constituents that traditional sampling approaches fail to capture, and will serve a critical role in monitoring, assessment and decision-making in a rapidly changing landscape.

  8. Development of a novel mixed hemimicelles dispersive micro solid phase extraction using 1-hexadecyl-3-methylimidazolium bromide coated magnetic graphene for the separation and preconcentration of fluoxetine in different matrices before its determination by fiber optic linear array spectrophotometry and mode-mismatched thermal lens spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kazemi, Elahe; Haji Shabani, Ali Mohammad [Department of Chemistry, Yazd University, Safaieh, 89195-741, Yazd (Iran, Islamic Republic of); Dadfarnia, Shayessteh, E-mail: sdadfarnia@yazd.ac.ir [Department of Chemistry, Yazd University, Safaieh, 89195-741, Yazd (Iran, Islamic Republic of); Abbasi, Amir [Department of Physics, Yazd University, Safaieh, 89195-741, Yazd (Iran, Islamic Republic of); Rashidian Vaziri, Mohammad Reza [Laser and Optics Research School, 14155-1339, Tehran (Iran, Islamic Republic of); Behjat, Abbas [Department of Physics, Yazd University, Safaieh, 89195-741, Yazd (Iran, Islamic Republic of)

    2016-01-28

    This study aims at developing a novel, sensitive, fast, simple and convenient method for separation and preconcentration of trace amounts of fluoxetine before its spectrophotometric determination. The method is based on combination of magnetic mixed hemimicelles solid phase extraction and dispersive micro solid phase extraction using 1-hexadecyl-3-methylimidazolium bromide coated magnetic graphene as a sorbent. The magnetic graphene was synthesized by a simple coprecipitation method and characterized by X-ray diffraction (XRD), Fourier transform infrared (FT-IR) spectroscopy and scanning electron microscopy (SEM). The retained analyte was eluted using a 100 μL mixture of methanol/acetic acid (9:1) and converted into fluoxetine-β-cyclodextrin inclusion complex. The analyte was then quantified by fiber optic linear array spectrophotometry as well as mode-mismatched thermal lens spectroscopy (TLS). The factors affecting the separation, preconcentration and determination of fluoxetine were investigated and optimized. With a 50 mL sample and under optimized conditions using the spectrophotometry technique, the method exhibited a linear dynamic range of 0.4–60.0 μg L{sup −1}, a detection limit of 0.21 μg L{sup −1}, an enrichment factor of 167, and a relative standard deviation of 2.1% and 3.8% (n = 6) at 60 μg L{sup −1} level of fluoxetine for intra- and inter-day analyses, respectively. However, with thermal lens spectrometry and a sample volume of 10 mL, the method exhibited a linear dynamic range of 0.05–300 μg L{sup −1}, a detection limit of 0.016 μg L{sup −1} and a relative standard deviation of 3.8% and 5.6% (n = 6) at 60 μg L{sup −1} level of fluoxetine for intra- and inter-day analyses, respectively. The method was successfully applied to determine fluoxetine in pharmaceutical formulation, human urine and environmental water samples. - Graphical abstract: A novel, sensitive, fast, simple and convenient mixed hemimicelles

  9. Development of a novel mixed hemimicelles dispersive micro solid phase extraction using 1-hexadecyl-3-methylimidazolium bromide coated magnetic graphene for the separation and preconcentration of fluoxetine in different matrices before its determination by fiber optic linear array spectrophotometry and mode-mismatched thermal lens spectroscopy

    International Nuclear Information System (INIS)

    Kazemi, Elahe; Haji Shabani, Ali Mohammad; Dadfarnia, Shayessteh; Abbasi, Amir; Rashidian Vaziri, Mohammad Reza; Behjat, Abbas

    2016-01-01

    This study aims at developing a novel, sensitive, fast, simple and convenient method for separation and preconcentration of trace amounts of fluoxetine before its spectrophotometric determination. The method is based on combination of magnetic mixed hemimicelles solid phase extraction and dispersive micro solid phase extraction using 1-hexadecyl-3-methylimidazolium bromide coated magnetic graphene as a sorbent. The magnetic graphene was synthesized by a simple coprecipitation method and characterized by X-ray diffraction (XRD), Fourier transform infrared (FT-IR) spectroscopy and scanning electron microscopy (SEM). The retained analyte was eluted using a 100 μL mixture of methanol/acetic acid (9:1) and converted into fluoxetine-β-cyclodextrin inclusion complex. The analyte was then quantified by fiber optic linear array spectrophotometry as well as mode-mismatched thermal lens spectroscopy (TLS). The factors affecting the separation, preconcentration and determination of fluoxetine were investigated and optimized. With a 50 mL sample and under optimized conditions using the spectrophotometry technique, the method exhibited a linear dynamic range of 0.4–60.0 μg L −1 , a detection limit of 0.21 μg L −1 , an enrichment factor of 167, and a relative standard deviation of 2.1% and 3.8% (n = 6) at 60 μg L −1 level of fluoxetine for intra- and inter-day analyses, respectively. However, with thermal lens spectrometry and a sample volume of 10 mL, the method exhibited a linear dynamic range of 0.05–300 μg L −1 , a detection limit of 0.016 μg L −1 and a relative standard deviation of 3.8% and 5.6% (n = 6) at 60 μg L −1 level of fluoxetine for intra- and inter-day analyses, respectively. The method was successfully applied to determine fluoxetine in pharmaceutical formulation, human urine and environmental water samples. - Graphical abstract: A novel, sensitive, fast, simple and convenient mixed hemimicelles dispersive micro solid

  10. A microcapillary lens for X-rays

    CERN Document Server

    Dudchik, Y I

    1999-01-01

    A new design of a compound refractive lens for X-rays is proposed. The lens is made as a set of glue microlenses placed in a glass capillary. The technique of lens fabrication is described. Results of ray tracing calculations for 8 and 15 keV photons are represented.

  11. Retinal images in the human eye with implanted intraocular lens

    Science.gov (United States)

    Zając, Marek; Siedlecki, Damian; Nowak, Jerzy

    2007-04-01

    A typical proceeding in cataract is based on the removal of opaque crystalline lens and inserting in its place the artificial intraocular lens (IOL). The quality of retinal image after such procedure depends, among others, on the parameters of the IOL, so the design of the implanted lens is of great importance. An appropriate choice of the IOL material, especially in relation to its biocompatibility, is often considered. However the parameter, which is often omitted during the IOL design is its chromatic aberration. In particular lack of its adequacy to the chromatic aberration of a crystalline lens may cause problems. In order to fit better chromatic aberration of the eye with implanted IOL to that of the healthy eye we propose a hybrid - refractive-diffractive IOL. It can be designed in such way that the total longitudinal chromatic aberration of an eye with implanted IOL equals the total longitudinal chromatic aberration of a healthy eye. In this study we compare the retinal image quality calculated numerically on the basis of the well known Liou-Brennan eye model with typical IOL implanted with that obtained if the IOL is done as hybrid (refractive-diffractive) design.

  12. Reproducibility of optical quality parameters measured at objective and subjective best focuses in a double-pass system

    Directory of Open Access Journals (Sweden)

    Ai-Lian Hu

    2015-10-01

    Full Text Available AIM:To evaluate intra-session repeatability and reproducibility of optical quality parameters measured at objective and subjective best focuses in a double-pass system.METHODS: Thirty Chinese healthy adults (19 to 40 years old meeting our inclusion criterion were enrolled in the study. After a basic eye examination, two methods of optical quality measurement, based on subjective and objective best focuses were performed using the Optical Quality Analysis System (OQAS with an artificial pupil diameter of 4.0 mm.RESULTS: With each method, three consecutive measurements of the following parameters:the modulation transfer function cutoff frequency (MTFcutoff, the Strehl2D ratio, the OQAS values (OVs at contrasts of 100%, 20%, 9% and the objective scatter index (OSI were performed by an experienced examiner. The repeatability of each method was evaluated by the repeatability limit (RL and the coefficient of repeatability (COR. Reproducibility of the two methods was evaluated by intra-class correlation coefficient (ICC and the 95% limits of agreement (Bland and Altman analysis. Thirty subjects, seven females and twenty three males, of whom 15 right eyes and 15 left eyes were selected randomly for recruitment in the study. The RLs (percentage for the six parameters measured at objective focus and subjective focus ranged from 8.44% to 15.13% and 10.85% to 16.26%, respectively. The CORs for the two measurement methods ranged from 8.27% to 14.83% and 10.63% to 15.93%, respectively. With regard to reproducibility, the ICCs for the six parameters of OQAS ranged from 0.024 to 0.276. The 95% limits of agreement obtained for the six parameters (in comparison of the two methods ranged from -0.57 to 42.18 (MTFcutoff, -0.01 to 0.23 (Strehl2D ratio, -0.02 to 1.40 (OV100%, -0.10 to 1.75 (OV20%, -0.14 to 1.80 (OV9% and -1.46 to 0.18 (OSI.CONCLUSION:Measurements provided by OQAS with either method showed a good repeatability. However, the results obtained from the

  13. Including 10-Gigabit-capable Passive Optical Network under End-to-End Generalized Multi-Protocol Label Switching Provisioned Quality of Service

    Science.gov (United States)

    Brewka, Lukasz; Gavler, Anders; Wessing, Henrik; Dittmann, Lars

    2012-04-01

    End-to-end quality of service provisioning is still a challenging task despite many years of research and development in this area. Considering a generalized multi-protocol label switching based core/metro network and resource reservation protocol capable home gateways, it is the access part of the network where quality of service signaling is bridged. This article proposes strategies for generalized multi-protocol label switching control over next emerging passive optical network standard, i.e., the 10-gigabit-capable passive optical network. Node management and resource allocation approaches are discussed, and possible issues are raised. The analysis shows that consideration of a 10-gigabit-capable passive optical network as a generalized multi-protocol label switching controlled domain is valid and may advance end-to-end quality of service provisioning for passive optical network based customers.

  14. Including 10-Gigabit-capable Passive Optical Network under End-to-End Generalized Multi-Protocol Label Switching Provisioned Quality of Service

    DEFF Research Database (Denmark)

    Brewka, Lukasz Jerzy; Gavler, Anders; Wessing, Henrik

    2012-01-01

    of the network where quality of service signaling is bridged. This article proposes strategies for generalized multi-protocol label switching control over next emerging passive optical network standard, i.e., the 10-gigabit-capable passive optical network. Node management and resource allocation approaches...... are discussed, and possible issues are raised. The analysis shows that consideration of a 10-gigabit-capable passive optical network as a generalized multi-protocol label switching controlled domain is valid and may advance end-to-end quality of service provisioning for passive optical network based customers.......End-to-end quality of service provisioning is still a challenging task despite many years of research and development in this area. Considering a generalized multi-protocol label switching based core/metro network and resource reservation protocol capable home gateways, it is the access part...

  15. The Ultrawideband Leaky Lens Antenna

    NARCIS (Netherlands)

    Bruni, S.; Neto, A.; Marliani, F.

    2007-01-01

    A novel directive and nondispersive antenna is presented: the ultrawideband (UWB) leaky lens. It is based on the broad band Cherenkov radiation occurring at a slot printed between different infinite homogeneous dielectrics. The first part of the paper presents the antenna concept and the UWB design.

  16. Adaptive optics photoacoustic microscopy.

    Science.gov (United States)

    Jiang, Minshan; Zhang, Xiangyang; Puliafito, Carmen A; Zhang, Hao F; Jiao, Shuliang

    2010-10-11

    We have developed an adaptive optics photoacoustic microscope (AO-PAM) for high-resolution imaging of biological tissues, especially the retina. To demonstrate the feasibility of AO-PAM we first designed the AO system to correct the wavefront errors of the illuminating light of PAM. The aberrations of the optical system delivering the illuminating light to the sample in PAM was corrected with a close-loop AO system consisting of a 141-element MEMS-based deformable mirror (DM) and a Shack-Hartmann (SH) wavefront sensor operating at 15 Hz. The photoacoustic signal induced by the illuminating laser beam was detected by a custom-built needle ultrasonic transducer. When the wavefront errors were corrected by the AO system, the lateral resolution of PAM was measured to be better than 2.5 µm using a low NA objective lens. We tested the system on imaging ex vivo ocular samples, e.g., the ciliary body and retinal pigment epithelium (RPE) of a pig eye. The AO-PAM images showed significant quality improvement. For the first time we were able to resolve single RPE cells with PAM.

  17. New trends in intraocular lens imaging

    Science.gov (United States)

    Millán, María S.; Alba-Bueno, Francisco; Vega, Fidel

    2011-08-01

    As a result of modern technological advances, cataract surgery can be seen as not only a rehabilitative operation, but a customized procedure to compensate for important sources of image degradation in the visual system of a patient, such as defocus and some aberrations. With the development of new materials, instruments and surgical techniques in ophthalmology, great progress has been achieved in the imaging capability of a pseudophakic eye implanted with an intraocular lens (IOL). From the very beginning, optical design has played an essential role in this progress. New IOL designs need, on the one hand, theoretical eye models able to predict optical imaging performance and on the other hand, testing methods, verification through in vitro and in vivo measurements, and clinical validation. The implant of an IOL requires a precise biometry of the eye, a prior calculation from physiological data, and an accurate position inside the eye. Otherwise, the effects of IOL calculation errors or misplacements degrade the image very quickly. The incorporation of wavefront aberrometry into clinical ophthalmology practice has motivated new designs of IOLs to compensate for high order aberrations in some extent. Thus, for instance, IOLs with an aspheric design have the potential to improve optical performance and contrast sensitivity by reducing the positive spherical aberration of human cornea. Monofocal IOLs cause a complete loss of accommodation that requires further correction for either distance or near vision. Multifocal IOLs address this limitation using the principle of simultaneous vision. Some multifocal IOLs include a diffractive zone that covers the aperture in part or totally. Reduced image contrast and undesired visual phenomena, such as halos and glare, have been associated to the performance of multifocal IOLs. Based on a different principle, accommodating IOLs rely on the effort of the ciliary body to increase the effective power of the optical system of the

  18. On the homogeneity of a thick layer of mixed granules in optical quality inspection

    NARCIS (Netherlands)

    Bakker, M.C.M.; Xia, H.

    2016-01-01

    Optical inspection of a thick layer of granules for foreign particles does not directly reveal their true number and the more so if the layer is not homogenous. This raises questions such as “how do I know if the layer is homogenous?” and “what is the relation between the observable particles and

  19. Biologically inspired LED lens from cuticular nanostructures of firefly lantern

    Science.gov (United States)

    Kim, Jae-Jun; Lee, Youngseop; Kim, Ha Gon; Choi, Ki-Ju; Kweon, Hee-Seok; Park, Seongchong; Jeong, Ki-Hun

    2012-01-01

    Cuticular nanostructures found in insects effectively manage light for light polarization, structural color, or optical index matching within an ultrathin natural scale. These nanostructures are mainly dedicated to manage incoming light and recently inspired many imaging and display applications. A bioluminescent organ, such as a firefly lantern, helps to out-couple light from the body in a highly efficient fashion for delivering strong optical signals in sexual communication. However, the cuticular nanostructures, except the light-producing reactions, have not been well investigated for physical principles and engineering biomimetics. Here we report a unique observation of high-transmission nanostructures on a firefly lantern and its biological inspiration for highly efficient LED illumination. Both numerical and experimental results clearly reveal high transmission through the nanostructures inspired from the lantern cuticle. The nanostructures on an LED lens surface were fabricated by using a large-area nanotemplating and reconfigurable nanomolding with heat-induced shear thinning. The biologically inspired LED lens, distinct from a smooth surface lens, substantially increases light transmission over visible ranges, comparable to conventional antireflection coating. This biological inspiration can offer new opportunities for increasing the light extraction efficiency of high-power LED packages. PMID:23112185

  20. Lens stem cells may reside outside the lens capsule: an hypothesis

    Directory of Open Access Journals (Sweden)

    Meyer Rita A

    2007-06-01

    Full Text Available Abstract In this paper, we consider the ocular lens in the context of contemporary developments in biological ideas. We attempt to reconcile lens biology with stem cell concepts and a dearth of lens tumors. Historically, the lens has been viewed as a closed system, in which cells at the periphery of the lens epithelium differentiate into fiber cells. Theoretical considerations led us to question whether the intracapsular lens is indeed self-contained. Since stem cells generate tumors and the lens does not naturally develop tumors, we reasoned that lens stem cells may not be present within the capsule. We hypothesize that lens stem cells reside outside the lens capsule, in the nearby ciliary body. Our ideas challenge the existing lens biology paradigm. We begin our discussion with lens background information, in order to describe our lens stem cell hypothesis in the context of published data. Then we present the ciliary body as a possible source for lens stem cells, and conclude by comparing the ocular lens with the corneal epithelium.

  1. Optical design of camera optics for mobile phones

    Science.gov (United States)

    Steinich, Thomas; Blahnik, Vladan

    2012-03-01

    At present, compact camera modules are included in many mobile electronic devices such as mobile phones, personal digital assistants or tablet computers. They have various uses, from snapshots of everyday situations to capturing barcodes for product information. This paper presents an overview of the key design challenges and some typical solutions. A lens design for a mobile phone camera is compared to a downscaled 35 mm format lens to demonstrate the main differences in optical design. Particular attention is given to scaling effects.

  2. Modern lens antennas for communications engineering

    CERN Document Server

    Thornton, John

    2012-01-01

    The aim of this book is to present the modern design principles and analysis of lens antennas. It gives graduates and RF/Microwave professionals the design insights in order to make full use of lens antennas.  Why do we want to write a book in lens antennas? Because this topic has not been thoroughly publicized, its importance is underestimated. As antennas play a key role in communication systems, recent development in wireless communications would indeed benefit from the characteristics of lens antennas: low profile, and low cost etc.  The major advantages of lens antennas are na

  3. Experimental synergy combining lidar measurements so as to optically characterize aerosols: applications to air quality and radiative forcing

    International Nuclear Information System (INIS)

    Raut, J.Ch.

    2008-09-01

    The work carried out in this study is devoted to a better understanding of the evolution of aerosol physical, chemical and optical properties for urban pollution aerosols, dust and biomass burning particles. It mainly concerns the complex refractive index and the single-scattering albedo. Such a characterisation is indeed necessary so as to fulfil the requirements of scientific and societal air quality and global climate evolution questions. Our study is based on a synergy between different measurements platforms: ground-based or airborne measurements, together with active and passive remote sensing observations. Lidar in particular turns out to be an essential tool in order to assess horizontal and vertical variability of aerosol micro-physical and optical properties in the atmospheric boundary layer, but also in the residual layer, as well as in layers transported from the boundary layer to the free troposphere. The original methodology we developed highlights the importance of the geographical origin, the impact of aging and dynamical processes in the evolution of structural, optical and hygroscopic aerosol features. The related accurate determination of the properties in each aerosol layer is required for radiative fluxes and heating rates calculations in the atmospheric column. The radiative impact of both dust particles and biomass burning aerosols observed over the region of Niamey (Niger) was thus assessed during the dry season. These results reveal the need of a better characterisation of those significant aerosol properties for each layer in models. (author)

  4. Performance analysis on quality of optical frequency comb generated by the recirculating frequency shifter based on linear IQ modulator

    Science.gov (United States)

    Sun, Lu; Li, Jianping; Lin, Jiachuan; Xi, Lixia; Tang, Xianfeng; Zhang, Xiaoguang

    2015-11-01

    An optical frequency comb generator using a modified single-sideband recirculating frequency shifter scheme adopting a linear IQ modulator as the kernel device (SSB-RFS-LIQM) is proposed. The optical comb lines generated by the proposed scheme possess good features such as extreme flatness and high optical signal-to-noise ratio (OSNR), compared to the quality we can obtain when we use a conventional IQ modulator in the SSB-RFS structure (called SSB-RFS-CIQM scheme). The mechanism of how the SSB-RFS-LIQM works is carefully analyzed with analytical and numerical methods. With the capability of strong suppression of high-order crosstalk and less demand of the gain of erbium-doped fiber amplifiers (and hence less amplified spontaneous noise induced) in the loop, 5.5 dB OSNR improvement can be achieved when 100 extreme flat comb lines are generated using the SSB-RFS-LIQM scheme compared to using the SSB-RFS-CIQM scheme.

  5. 3D field-shaping lens using all-dielectric gradient refractive index materials.

    Science.gov (United States)

    Ding, Tongyu; Yi, Jianjia; Li, Haoyu; Zhang, Hailin; Burokur, Shah Nawaz

    2017-04-10

    A novel three-dimensional (3D) optical lens structure for electromagnetic field shaping based on spatial light transformation method is proposed at microwave frequencies. The lens is capable of transforming cylindrical wavefronts into planar ones, and generating a directive emission. Such manipulation is simulated and analysed by solving Laplace's equation, and the deformation of the medium during the transformation is theoretically described in detail. The two-dimensional (2D) design method producing quasi-isotropic parameters is further extended to a potential 3D realization with all-dielectric gradient refractive index metamaterials. Numerical full-wave simulations are performed on both 2D and 3D models to verify the functionality and broadband characteristics of the calculated lens. Far-field radiation patterns and near-field distributions demonstrate a highly radiated directive beam when the lens is applied to a conical horn antenna.

  6. Stretch-dependent changes in surface profiles of the human crystalline lens during accommodation: a finite element study.

    Science.gov (United States)

    Pour, Hooman Mohammad; Kanapathipillai, Sangarapillai; Zarrabi, Khosrow; Manns, Fabrice; Ho, Arthur

    2015-03-01

    A non-linear isotropic finite element (FE) model of a 29-year-old human crystalline lens was constructed to study the effects of various geometrical parameters on lens accommodation. The model simulates dis-accommodation by stretching of the lens and predicts the change in surface profiles of the lens capsule, cortex and nucleus at select states of stretching/accommodation. Multiple regression analysis (MRA) is used to develop a stretch-dependent mathematical model relating the lens sagittal height to the radial position of the lens surface as a function of dis-accommodative stretch. A load analysis is performed to compare the finite element results to empirical results from lens stretcher studies. Using the predicted geometrical changes, the optical response of the whole eye during accommodation was analysed by ray-tracing. Aspects of lens shape change relative to stretch were evaluated, including change in diameter, central thickness and accommodation. Maximum accommodation achieved was 10.29 D. From the multiple regression analysis, the stretch-dependent mathematical model of the lens shape related lens curvatures as a function of lens ciliary stretch well (maximum mean-square residual error 2.5 × 10(-3 ) μm, p < 0.001). The results are compared with those from in vitro studies. The finite element and ray-tracing predictions are consistent with Ex Vivo Accommodation Simulator (EVAS) studies in terms of load and power change versus change in thickness. The mathematical stretch-dependent model of accommodation presented may have utility in investigating lens behaviour at states other than the relaxed or fully accommodated states. © 2015 The Authors. Clinical and Experimental Optometry © 2015 Optometry Australia.

  7. Multiple-aperture optical design for micro-level cameras using 3D-printing method

    Science.gov (United States)

    Peng, Wei-Jei; Hsu, Wei-Yao; Cheng, Yuan-Chieh; Lin, Wen-Lung; Yu, Zong-Ru; Chou, Hsiao-Yu; Chen, Fong-Zhi; Fu, Chien-Chung; Wu, Chong-Syuan; Huang, Chao-Tsung

    2018-02-01

    The design of the ultra miniaturized camera using 3D-printing technology directly printed on to the complementary metal-oxide semiconductor (CMOS) imaging sensor is presented in this paper. The 3D printed micro-optics is manufactured using the femtosecond two-photon direct laser writing, and the figure error which could achieve submicron accuracy is suitable for the optical system. Because the size of the micro-level camera is approximately several hundreds of micrometers, the resolution is reduced much and highly limited by the Nyquist frequency of the pixel pitch. For improving the reduced resolution, one single-lens can be replaced by multiple-aperture lenses with dissimilar field of view (FOV), and then stitching sub-images with different FOV can achieve a high resolution within the central region of the image. The reason is that the angular resolution of the lens with smaller FOV is higher than that with larger FOV, and then the angular resolution of the central area can be several times than that of the outer area after stitching. For the same image circle, the image quality of the central area of the multi-lens system is significantly superior to that of a single-lens. The foveated image using stitching FOV breaks the limitation of the resolution for the ultra miniaturized imaging system, and then it can be applied such as biomedical endoscopy, optical sensing, and machine vision, et al. In this study, the ultra miniaturized camera with multi-aperture optics is designed and simulated for the optimum optical performance.

  8. Lens refracting cost effective photovoltaic solar energy concentrating systems

    International Nuclear Information System (INIS)

    Pilawjian, G.A.

    2014-01-01

    The overall cost reduction task is studied for photovoltaic (PV) solar energy systems. For that purpose, a new, cost effective lens refracting system is developed. The concentrating system consists of Fresnel lenses placed under different facet angles refracting the sun light onto the solar cells placed along a line. The developed photovoltaic concentrating system uses the mathematical model of Fresnel lens concentrating optics for photovoltaic systems used to optimize the system by cost. A computer program FLCPVSys2.1 for the new concentrating system is developed allowing to design a photovoltaic system of the required power with the minimum cost. The program can be used for designing a cost effective photovoltaic solar concentrating system

  9. Wide-field schematic eye models with gradient-index lens.

    Science.gov (United States)

    Goncharov, Alexander V; Dainty, Chris

    2007-08-01

    We propose a wide-field schematic eye model, which provides a more realistic description of the optical system of the eye in relation to its anatomical structure. The wide-field model incorporates a gradient-index (GRIN) lens, which enables it to fulfill properties of two well-known schematic eye models, namely, Navarro's model for off-axis aberrations and Thibos's chromatic on-axis model (the Indiana eye). These two models are based on extensive experimental data, which makes the derived wide-field eye model also consistent with that data. A mathematical method to construct a GRIN lens with its iso-indicial contours following the optical surfaces of given asphericity is presented. The efficiency of the method is demonstrated with three variants related to different age groups. The role of the GRIN structure in relation to the lens paradox is analyzed. The wide-field model with a GRIN lens can be used as a starting design for the eye inverse problem, i.e., reconstructing the optical structure of the eye from off-axis wavefront measurements. Anatomically more accurate age-dependent optical models of the eye could ultimately help an optical designer to improve wide-field retinal imaging.

  10. Quality Assurance Programme for the Environmental Testing of the CMS Tracker Optical Links

    CERN Document Server

    Gill, K; Troska, Jan K; Vasey, F; Zanet, A

    2001-01-01

    The QA programme is reviewed for the environmental compliance tests of commercial off-the-shelf (COTS) components for the CMS Tracker Optical link system. These environmental tests will take place in the pre-production and final production phases of the project and will measure radiation resistance, component lifetime, and sensitivity to magnetic fields. The evolution of the programme from small-scale prototype tests to the final pre-production manufacturing tests is outlined and the main environmental effects expected for optical links operating within the Tracker are summarised. A special feature of the environmental QA programme is the plan for Advance Validation Tests (AVT's) developed in close collaboration with the various industrial partners. AVT procedures involve validation of a relatively small set of basic samples in advance of the full production of the corresponding batch of devices. Only those lots that have been confirmed as sufficiently rad-tolerant will be purchased and used in the final prod...

  11. The Charles F. Prentice award lecture 2009: Crystalline lens research and serendipity in science.

    Science.gov (United States)

    Sivak, Jacob Gershon

    2010-09-01

    Whether it is called serendipity or creativity, the process of scientific discovery is not one that lends itself to advance planning or programming, nor does it lend itself to an emphasis solely on applied research, research with industrial partners, or large teams of researchers because researchers must rely on intuition and the capacity to move quickly in new directions. Studies in my laboratory began with efforts to relate lens embryonic development to lens optical performance in a variety of vertebrate species. The initial direction concerned the optics of the fish eye, a system in which a spherical lens is essentially the only refractive component of the eye and one in which accommodation takes place by means of lens movement. This in turn led to an interest in how amphibious animals cope with the refractive transition that takes place when moving from air to water and vice versa. The development of a super accommodative ability in some diving birds is one adaptation that was explored. These curiosity-driven efforts led in turn to the development of a scanning laser system that provided a tool that can be used to evaluate the process of cataract development, either on the basis of in vivo exposure to chemicals or electromagnetic radiation and subsequent analysis of the excised lens or to the in vitro study of the lens in long-term whole lens culture experiments. The same approach has also been used as an in vitro ocular toxicology assay to develop sensitive in vitro methods to reduce regulatory dependence on the use of live animals. Finally, these applied directions in turn created new basic knowledge concerning the morphology and physiology of eye tissue organelles, particularly the morphology, distribution, and dynamic properties of the mitochondria found in the lens and in the retinal pigment epithelium.

  12. High optical quality nanocrystalline diamond with reduced non-diamond contamination

    Czech Academy of Sciences Publication Activity Database

    Remeš, Zdeněk; Ižák, Tibor; Kromka, Alexander; Vaněček, Milan

    2010-01-01

    Roč. 19, 5-6 (2010), s. 453-456 ISSN 0925-9635 R&D Projects: GA MŠk LC510; GA AV ČR(CZ) IAAX00100902 Institutional research plan: CEZ:AV0Z10100521 Keywords : nanocrystalline diamond * photocurrent spectra * optical absorption * laser calorimetry Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.825, year: 2010

  13. Optical Magnification Should Be Mandatory for Microsurgery: Scientific Basis and Clinical Data Contributing to Quality Assurance

    Directory of Open Access Journals (Sweden)

    Harald Schoeffl

    2013-03-01

    Full Text Available BackgroundMicrosurgical techniques are considered standard procedures in reconstructive surgery. Although microsurgery by itself is defined as surgery aided by optical magnification, there are no guidelines for determining in which clinical situations a microscope or loupe should be used. Therefore, we conducted standardized experiments to objectively assess the impact of optical magnification in microsurgery.MethodsSixteen participants of microsurgical training courses had to complete 2 sets of experiments. Each set had to be performed with an unaided eye, surgical loupes, and a regular operating microscope. The first set of experiments included coaptation of a chicken femoral nerve, and the second set consisted of anastomosing porcine coronary arteries. Evaluation of the sutured nerves and vessels were performed by 2 experienced microsurgeons using an operating microscope.ResultsThe 16 participants of the study completed all of the experiments. The nerve coaptation and vascular anastomoses exercises showed a direct relationship of error frequency and lower optical magnification, meaning that the highest number of microsurgical errors occurred with the unaided eye. For nerve coaptation, there was a strong relationship (P<0.05 between the number of mistakes and magnification, and this relationship was very strong (P<0.01 for vascular anastomoses.ConclusionsWe were able to prove that microsurgical success is directly related to optical magnification. The human eye's ability to discriminate potentially important anatomical structures is limited, which might be detrimental for clinical results. Although not legally mandatory, surgeries such as reparative surgery after hand trauma should be conducted with magnifying devices for achieving optimal patient outcomes.

  14. Quality Assurance Programme for the Environmental Testing of the CMS Tracker Optical Links

    OpenAIRE

    Gill, K; Grabit, R; Troska, Jan K; Vasey, F; Zanet, A

    2001-01-01

    The QA programme is reviewed for the environmental compliance tests of commercial off-the-shelf (COTS) components for the CMS Tracker Optical link system. These environmental tests will take place in the pre-production and final production phases of the project and will measure radiation resistance, component lifetime, and sensitivity to magnetic fields. The evolution of the programme from small-scale prototype tests to the final pre-production manufacturing tests is outlined and the main env...

  15. Physics of optical tweezers.

    Science.gov (United States)

    Nieminen, Timo A; Knöner, Gregor; Heckenberg, Norman R; Rubinsztein-Dunlop, Halina

    2007-01-01

    We outline the basic principles of optical tweezers as well as the fundamental theory underlying optical tweezers. The optical forces responsible for trapping result from the transfer of momentum from the trapping beam to the particle and are explained in terms of the momenta of incoming and reflected or refracted rays. We also consider the angular momentum flux of the beam in order to understand and explain optical torques. In order to provide a qualitative picture of the trapping, we treat the particle as a weak positive lens and the forces on the lens are shown. However, this representation does not provide quantitative results for the force. We, therefore, present results of applying exact electromagnetic theory to optical trapping. First, we consider a tightly focused laser beam. We give results for trapping of spherical particles and examine the limits of trappability in terms of type and size of the particles. We also study the effect of a particle on the beam. This exact solution reproduces the same qualitative effect as when treating the particle as a lens where changes in the convergence or divergence and in the direction of the trapping beam result in restoring forces acting on the particle. Finally, we review the fundamental theory of optical tweezers.

  16. Effect of Time on Scleral Lens Settling and Change in Corneal Clearance.

    Science.gov (United States)

    Otchere, Heinz; Jones, Lyndon W; Sorbara, Luigina

    2017-09-01

    With the increase in the use of scleral contact lenses among practitioners, questions regarding lens settling are gradually gaining attention. This is because current studies support the notion that scleral lenses settle back over time. More research is needed to understand the exact cause and the factors that underpin such phenomenon. The present study aims to assess the effect of time on topographic corneal clearance of three scleral contact lenses of varying sagittal depths. Three scleral contact lenses were fitted to 20 subjects with previous diagnosis of keratoconus (n = 18) or pellucid marginal degeneration (n = 2). The fit was based on corneal sagittal height measured with the Visante optical coherence tomographer (OCT) at 15 mm along the horizontal meridian. To select an appropriate lens from the diagnostic lens set, values of 325 μm (lens 1), 375 μm (lens 2), and 425 μm (lens 3) were randomly added in sequence to the corneal sagittal height. Subjects wore each lens for 1 hour. Corneal clearance was measured at 10-minute intervals for 1 hour using a custom ultra-long OCT. To assess change in clearance, central point and two mid-peripheral points (+3 mm and -3 mm) along an 8-mm chord were measured by taking differences at each time point up to 1 hour. Measurements were repeated for the two other lenses. Mean central corneal clearance loss for all three lenses was 33.83 ± 48.40 μm. This was 26 ± 27 μm (13 ± 14 μm, +3 mm; 34 ± 37 μm, -3 mm), lens 1; 35 ± 59 μm (38 ± 61 μm, +3 mm; 52 ± 69 μm, -3 mm), lens 2; and 41 ± 54 μm (33 ± 26 μm, +3 mm; 52 ± 48 μm, -3 mm), lens 3, respectively. There was no significant difference (P = 0.06) at central and other locations for lens 1 (location and over time). There were significant differences for both lenses 2 and 3 (P < .001, P = .01, respectively) for all three locations and over time. There is a likelihood of clearance loss after 1 hour of lens wear. This varies between subjects, initial lens

  17. Lighting molded optics: Design and manufacturing

    Directory of Open Access Journals (Sweden)

    Kočárková H.

    2013-05-01

    Full Text Available Proper design and manufacturing of glass molded lenses need to be performed in several steps. The whole process from customer requirements to f nal functional product is shown on two examples - a lens for street light and a lens for spot light with narrow lighting angle. After discussing customer requirements, optical design is made. Thanks to various commercial softwares with optimization, manufacturer of the lens can work as well as a designer which enables simplif cation and acceleration of lens manufacturing, since limitations of the manufacturing process are considered during creation of the design. When the prototype is made, its functionality needs to be evaluated. This work shows measurement of light distribution for street light lens in a dark room using goniometer and measurement of light intensity for spot lens f xed on an optical bench. These measurements can reveal the root cause in case of lens malfunction, which enables to optimize manufacturing process or modify lens design accordingly. Designing, manufacturing and evaluation of molded optics under one roof enables creation of easily manufacturable design and fast solution of problems.

  18. The current status of eye lens dose measurement in interventional cardiology personnel in Thailand.

    Science.gov (United States)

    Krisanachinda, Anchali; Srimahachota, Suphot; Matsubara, Kosuke

    2017-06-01

    Workers involved in interventional cardiology procedures receive high eye lens doses if radiation protection tools are not properly utilized. Currently, there is no suitable method for routine measurement of eye dose. In Thailand, the eye lens equivalent doses in terms of Hp(3) of the interventional cardiologists, nurses, and radiographers participating in interventional cardiology procedures have been measured at 12 centers since 2015 in the pilot study. The optically stimulated luminescence (OSL) dosimeter was used for measurement of the occupational exposure and the eye lens dose of 42 interventional cardiology personnel at King Chulalongkorn Memorial Hospital as one of the pilot centers. For all personnel, it is recommended that a first In Light OSL badge is placed at waist level and under the lead apron for determination of Hp(10); a second badge is placed at the collar for determination of Hp(0.07) and estimation of Hp(3). Nano Dots OSL dosimeter has been used as an eye lens dosimeter for 16 interventional cardiology personnel, both with and without lead-glass eyewear. The mean effective dose at the body, equivalent dose at the collar, and estimated eye lens dose were 0.801, 5.88, and 5.70 mSv per year, respectively. The mean eye lens dose measured by the Nano Dots dosimeter was 8.059 mSv per year on the left eye and 3.552 mSv per year on the right eye. Two of 16 interventional cardiologists received annual eye lens doses on the left side without lead glass that were higher than 20 mSv per year, the new eye lens dose limit as recommended by ICRP with the risk of eye lens opacity and cataract.

  19. A comparison of the short-term settling of three scleral lens designs.

    Science.gov (United States)

    Kauffman, Matthew J; Gilmartin, Christopher A; Bennett, Edward S; Bassi, Carl J

    2014-12-01

    Scleral gas-permeable lenses are rapidly gaining international popularity. Unlike corneal gas-permeable lenses, scleral lenses are fitted to the bulbar conjunctiva and settle into the tissue after insertion. To date, we are unaware of any studies examining the settling behavior of three varying scleral lens designs. The purpose of this study was to quantify the mean total settling and mean rates of settling for three scleral lens designs: Onefit P&A (Blanchard Contact Lens, Inc), Mini Scleral Design (msd) (Blanchard Contact Lens, Inc), and Jupiter (Visionary Optics). A randomized, repeated-measures study of Onefit P&A, msd, and Jupiter was performed. Subjects were fitted from a trial lens set, according to the manufacturer's guidelines. After insertion, lens settling was measured at 0 minutes, 15 minutes, 30 minutes, 45 minutes, 1 hour, 2 hours, 4 hours, 6 hours, and 8 hours. Statistical analyses were performed using analysis of variance and two-stage, nonlinear regression analyses of settling over time. On average, the Onefit P&A, msd, and Jupiter lenses settled a total of 113.7, 133.7, and 88.1 μm, respectively. Although the rates of settling were not linear, analysis of variance revealed a significant difference in the average settling rates (p lenses settled to about 80% of the final estimated values for the Onefit P&A lens, 90% for msd, and 99% for the Jupiter, after 8 hours. We concluded that the amount of settling varied significantly among the three lens designs. Settling rates were greatest shortly after insertion. Larger lenses were estimated to be settled by 8 hours. Based on the results of this short-term study, careful consideration to the settling patterns of individual scleral lens designs should be given.

  20. Ku80 Counters Oxidative Stress-Induced DNA Damage and Cataract Formation in the Human Lens.

    Science.gov (United States)

    Smith, Andrew John Oliver; Ball, Simon Sidney Robert; Manzar, Kamal; Bowater, Richard Peter; Wormstone, Ian Michael

    2015-12-01

    Oxidative stress in the human lens leads to a wide range of damage including DNA strand breaks, which are likely to contribute to cataract formation. The protein Ku80 is a fundamental component of the nonhomologous end-joining pathway that repairs DNA double strand breaks. This study investigates the putative impact of Ku80 in cataract prevention in the human lens. The present study used the human lens epithelial cell line FHL124 and whole human lens organ culture. Targeted siRNA was used to deplete Ku80, with Western blot and immunocytochemistry employed to assess Ku80 expression levels. Oxidative stress was induced with hydrogen peroxide and DNA strand breaks measured by alkaline comet assay and γH2AX foci counts. Visual quality of whole human lenses was measured with image analysis software. Expression of Ku80 was predominately found in the cell nucleus of both FHL124 cells and native human lens epithelium. Treatment of FHL124 cells and whole lens cultures with siRNA targeted against Ku80 resulted in a significant knockdown at the protein level. Application of oxidative stress (30 μM H2O2) created more DNA strand breaks when added to Ku80 knockdown cells than in scrambled siRNA control cells as determined by the alkaline comet assay and the number of γH2AX foci. In whole lens cultures, exposure to 1 mM H2O2 resulted in more lens opacity in Ku80 knockdown lenses than match-paired controls. Depletion of Ku80 in the lens through acute change or a consequence of aging is likely to increase levels of DNA strand breaks, which could negatively influence physiological function and promote lens opacity. It is therefore feasible that Ku80 plays a role in retarding cataract formation.

  1. A comprehensive comparison of IMRT and VMAT plan quality for orbital lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Soon Mi; Ban, Tae Joon; Yun, In Ha; Baek, Geum Mun; Kwon, Kyung Tae [Dept. of Radiation Oncology, Asan medical center, Seoul (Korea, Republic of)

    2014-12-15

    The purpose of this study is to compare the plan quality of volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) for the treatment of orbital lymphoma. IMRT, partial single arc(SA) and partial-double arc(DA) VMAT plans for four patients with orbital lymphoma treated at our institution were used for this study. Conformity Index(CI), Paddick's Conformity Index(PCI) and Homogeneity Index(HI) of planning target volume(PTV) were used to evaluate dosimetric quality of each plan. The Monitor Unit (MU), treatment time and dose of ipsilateral lens from each type of plan were measured for comparison. The CI of PTV for IMRT, SA and DA were measured as 0.88, 0.86, 0.92. The PCI of DA was the lowest as 1.33. Also HI of DA was the lowest in measured plans as 1.15. Mean dose of lens, lacrimal gland, optic chiasm, the opposite optic nerve and both orbit was analyzed with V30, V20, V10, V5. The result showed that the lowest dose in IMRT highest in SA in opposite lens, lacrimal gland, optic nerve, orbit. Results : Treatment time and average MU of IMRT was about three times higher than SA. Considering the superior plan quality as well as the delivery efficiency of VMAT compared with that of IMRT, VMAT may be the preferred modality for treating orbital lymphoma.

  2. Looking beyond the perfect lens

    International Nuclear Information System (INIS)

    Wee, W H; Pendry, J B

    2010-01-01

    The holy grail of imaging is the ability to see through anything. From the conservation of energy, we can easily see that to see through a lossy material would require lenses with gain. The aim of this paper therefore is to propose a simple scheme by which we can construct a general perfect lens, with gain-one that can restore both the phases and amplitudes of near and far fields.

  3. CONTACT LENS RELATED CORNEAL ULCER

    Directory of Open Access Journals (Sweden)

    AGARWAL P

    2010-01-01

    Full Text Available A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are:overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. The presenting symptoms of contact lens related corneal ulcers include eye discomfort, foreign body sensation and lacrimation. More serious symptoms are redness (especially circum-corneal injection, severe pain, photophobia, eye discharge and blurring of vision. The diagnosis is established by a thorough slit lamp microscopic examination with fluorescein staining and corneal scraping for Gram stain and culture of the infective organism. Delay in diagnosing and treatment can cause permanent blindness, therefore an early referral to ophthalmologist and commencing of antimicrobial therapy can prevent visual loss.

  4. Alternative technique for biodiesel quality control using an optical fiber long-period grating sensor

    Energy Technology Data Exchange (ETDEWEB)

    Falate, Rosane [Universidade Estadual de Ponta Grossa, PR (Brazil). Dept. de Informatica; Nike, Karen; Costa Neto, Pedro Ramos da [Universidade Tecnologica Federal do Parana, Curitiba (Brazil). Dept. de Quimica; Cacao Junior, Eduardo; Muller, Marcia; Kalinowski, Hypolito Jose; Fabris, Jose Luis [Universidade Tecnologica Federal do Parana, Curitiba (Brazil). Dept. de Fisica]. E-mail: fabris@utfpr.edu.br

    2007-07-01

    We report the use of an optical fiber sensor to measure the soybean oil concentration in samples obtained from the mixture of pure biodiesel and commercial soybean oil. The operation of the device is based on the long-period grating sensitivity to the surrounding medium refractive index, which leads to measurable modifications in the grating transmission spectrum. The proposed analysis method results in errors in the oil concentration of 0.4% and 2.6% for pure biodiesel and commercial soybean oil, respectively. Techniques of total glycerol, dynamic viscosity, density, and hydrogen nuclear magnetic resonance spectroscopy were also employed to validate the proposed method. (author)

  5. Alternative technique for biodiesel quality control using an optical fiber long-period grating sensor

    International Nuclear Information System (INIS)

    Falate, Rosane; Nike, Karen; Costa Neto, Pedro Ramos da; Cacao Junior, Eduardo; Muller, Marcia; Kalinowski, Hypolito Jose; Fabris, Jose Luis

    2007-01-01

    We report the use of an optical fiber sensor to measure the soybean oil concentration in samples obtained from the mixture of pure biodiesel and commercial soybean oil. The operation of the device is based on the long-period grating sensitivity to the surrounding medium refractive index, which leads to measurable modifications in the grating transmission spectrum. The proposed analysis method results in errors in the oil concentration of 0.4% and 2.6% for pure biodiesel and commercial soybean oil, respectively. Techniques of total glycerol, dynamic viscosity, density, and hydrogen nuclear magnetic resonance spectroscopy were also employed to validate the proposed method. (author)

  6. Digital adaptive optics confocal microscopy based on iterative retrieval of optical aberration from a guidestar hologram.

    Science.gov (United States)

    Liu, Changgeng; Thapa, Damber; Yao, Xincheng

    2017-04-03

    Guidestar hologram based digital adaptive optics (DAO) is one recently emerging active imaging modality. It records each complex distorted line field reflected or scattered from the sample by an off-axis digital hologram, measures the optical aberration from a separate off-axis digital guidestar hologram, and removes the optical aberration from the distorted line fields by numerical processing. In previously demonstrated DAO systems, the optical aberration was directly retrieved from the guidestar hologram by taking its Fourier transform and extracting the phase term. For the direct retrieval method (DRM), when the sample is not coincident with the guidestar focal plane, the accuracy of the optical aberration retrieved by DRM undergoes a fast decay, leading to quality deterioration of corrected images. To tackle this problem, we explore here an image metrics-based iterative method (MIM) to retrieve the optical aberration from the guidestar hologram. Using an aberrated objective lens and scattering samples, we demonstrate that MIM can improve the accuracy of the retrieved aberrations from both focused and defocused guidestar holograms, compared to DRM, to improve the robustness of the DAO.

  7. High-efficiency thin and compact concentrator photovoltaics with micro-solar cells directly attached to a lens array.

    Science.gov (United States)

    Hayashi, Nobuhiko; Inoue, Daijiro; Matsumoto, Mitsuhiro; Matsushita, Akio; Higuchi, Hiroshi; Aya, Youichirou; Nakagawa, Tohru

    2015-06-01

    We propose a thin and compact concentrator photovoltaic (CPV) module, about 20 mm thick, one tenth thinner than those of conventional CPVs that are widely deployed for mega-solar systems, to broaden CPV application scenarios. We achieved an energy conversion efficiency of 37.1% at a module temperature of 25 °C under sunlight irradiation optimized for our module. Our CPV module has a lens array consisting of 10 mm-square unit lenses and micro solar cells that are directly attached to the lens array, to reduce the focal length of the concentrator and to reduce optical losses due to reflection. The optical loss of the lens in our module is about 9.0%, which is lower than that of conventional CPV modules with secondary optics. This low optical loss enables our CPV module to achieve a high energy conversion efficiency.

  8. Highly sensitive straightness measurement system using a ball-lens

    International Nuclear Information System (INIS)

    Lee, Minho; Yang, Hyun-Ik; Cho, Nahm-Gyoo

    2016-01-01

    In this paper, a new and simple optical technique to accurately measure the straightness errors of a linear stage is proposed. To improve the performance, including the measurement sensitivity and resolution of the measurement system, and to simultaneously measure two-dimensional straightness errors (2D straightness errors), an optical system was designed using a laser, a retro-reflector, a ball-lens, and a two-dimensional position sensitive detector (2D PSD). The characteristics of the measurement system were analytically and experimentally investigated. A prototype measurement system was manufactured based on the investigated results, and the performances of this system have been tested. The measuring performance of the system was easily improved by about 12 times using the proposed technique and it can be further improved. It is shown that the proposed technique can easily and effectively improve the performance of a conventional straightness measurement system based on the geometric optical method using a PSD. (paper)

  9. Optical characterization of a miniaturized large field of view motion sensor

    Science.gov (United States)

    Moens, Els; Ottevaere, Heidi; Meuret, Youri; Thienpont, Hugo

    2012-06-01

    In this paper we discuss the geometrical and optical characterization of a miniaturized very wide field-of-view (FOV) motion sensor inspired by the working principle of insect facet eyes. The goal of the sensor is to detect movement in the environment and to specify where in the surroundings these changes took place. Based on the measurements of the sensor, certain actions can be taken such as sounding an alarm in security applications or turning on the light in domotic applications. The advantage of miniaturizing these sensors is that they are low-cost, compact and more esthetical compared to current motion detectors. The sensor was designed to have a very large FOV of 125° and an angular resolution of 1° or better. The micro-optics is built up of two stacked polymer plates consisting each out of a five by five lens array. In between there is a plate of absorbing material with a five by five array of baffles to create 25 optically isolated channels that each image part of the total FOV of 125° onto the detector. To geometrically characterize the lens arrays and verify the designed specifications, we made use of a coordinate measuring machine. The optical performance of the designed micro-optical system was analyzed by sending white light beams with different angles of incidence with respect to the sample through the sensor, comparing the position of the light spots visible on the detector and determining optical quality parameters such as MTF and distortion.

  10. Fabrication of a Micro-Lens Array Mold by Micro Ball End-Milling and Its Hot Embossing

    Directory of Open Access Journals (Sweden)

    Peng Gao

    2018-02-01

    Full Text Available Hot embossing is an efficient technique for manufacturing high-quality micro-lens arrays. The machining quality is significant for hot embossing the micro-lens array mold. This study investigates the effects of micro ball end-milling on the machining quality of AISI H13 tool steel used in the micro-lens array mold. The micro ball end-milling experiments were performed under different machining strategies, and the surface roughness and scallop height of the machined micro-lens array mold are measured. The experimental results showed that a three-dimensional (3D offset spiral strategy could achieve a higher machining quality in comparison with other strategies assessed in this study. Moreover, the 3D offset spiral strategy is more appropriate for machining the micro-lens array mold. With an increase of the cutting speed and feed rate, the surface roughness of the micro-lens array mold slightly increases, while a small step-over can greatly reduce the surface roughness. In addition, a hot embossing experiment was undertaken, and the obtained results indicated higher-quality production of the micro-lens array mold by the 3D offset spiral strategy.

  11. Image quality analysis of high-density diffuse optical tomography incorporating a subject-specific head model

    Directory of Open Access Journals (Sweden)

    Yuxuan eZhan

    2012-05-01

    Full Text Available High-density diffuse optical tomography (HD-DOT methods have shown significant improvement in localization accuracy and image resolution compared to traditional topographic near infrared spectroscopy (NIRS of the human brain. In this work we provide a comprehensive evaluation of image quality in visual cortex mapping via a simulation study with the use of an anatomical head model derived from MRI data of a human subject. A model of individual head anatomy provides the surface shape and internal structure that allow for the construction of a more realistic physical model for the forward problem, as well as the use of a structural constraint in the inverse problem. The HD-DOT model utilized here incorporates multiple source-detector separations with continuous-wave data with added noise based on experimental results. To evaluate image quality we quantify the localization error and localized volume at half maximum (LVHM throughout a region of interest (ROI within the visual cortex and systematically analyze the use of whole brain tissue spatial constraint within image reconstruction. Our results demonstrate that an image quality with less than 10 mm in localization error and 1000 m3 in LVHM can be obtained up to 13 mm below the scalp surface with a typical unconstrained reconstruction and up to 18 mm deep when a spatial constraint based on the brain tissue is utilized.

  12. Data-based online nonlinear extremum-seeker for wavefront sensorless adaptive optics OCT (Conference Presentation)

    Science.gov (United States)

    Jian, Yifan; Verstraete, Hans R. G. W.; Heisler, Morgan; Ju, Myeong Jin; Wahl, Daniel J.; Bliek, Laurens; Kalkman, Jeroen; Bonora, Stefano; Verhaegen, Michel; Sarunic, Marinko V.

    2017-02-01

    Adaptive optics has been successfully applied to cellular resolution imaging of the retina, enabling visualization of the characteristic mosaic patterns of the outer retina. Wavefront sensorless adaptive optics (WSAO) is a novel technique that facilitates high resolution ophthalmic imaging; it replaces the Hartmann-Shack Wavefront Sensor with an image-driven optimization algorithm and mitigates some the challenges encountered with sensor-based designs. However, WSAO generally requires longer time to perform aberrations correction than the conventional closed-loop adaptive optics. When used for in vivo retinal imaging applications, motion artifacts during the WSAO optimization process will affect the quality of the aberration correction. A faster converging optimization scheme needs to be developed to account for rapid temporal variation of the wavefront and continuously apply corrections. In this project, we investigate the Databased Online Nonlinear Extremum-seeker (DONE), a novel non-linear multivariate optimization algorithm in combination with in vivo human WSAO OCT imaging. We also report both hardware and software updates of our compact lens based WSAO 1060nm swept source OCT human retinal imaging system, including real time retinal layer segmentation and tracking (ILM and RPE), hysteresis correction for the multi-actuator adaptive lens, precise synchronization control for the 200kHz laser source, and a zoom lens unit for rapid switching of the field of view. Cross sectional images of the retinal layers and en face images of the cone photoreceptor mosaic acquired in vivo from research volunteers before and after WSAO optimization are presented.

  13. High-Mobility and High-Optical Quality Atomically Thin WS 2.

    Science.gov (United States)

    Reale, Francesco; Palczynski, Pawel; Amit, Iddo; Jones, Gareth F; Mehew, Jake D; Bacon, Agnes; Ni, Na; Sherrell, Peter C; Agnoli, Stefano; Craciun, Monica F; Russo, Saverio; Mattevi, Cecilia

    2017-11-02

    The rise of atomically thin materials has the potential to enable a paradigm shift in modern technologies by introducing multi-functional materials in the semiconductor industry. To date the growth of high quality atomically thin semiconductors (e.g. WS 2 ) is one of the most pressing challenges to unleash the potential of these materials and the growth of mono- or bi-layers with high crystal quality is yet to see its full realization. Here, we show that the novel use of molecular precursors in the controlled synthesis of mono- and bi-layer WS 2 leads to superior material quality compared to the widely used direct sulfidization of WO 3 -based precursors. Record high room temperature charge carrier mobility up to 52 cm 2 /Vs and ultra-sharp photoluminescence linewidth of just 36 meV over submillimeter areas demonstrate that the quality of this material supersedes also that of naturally occurring materials. By exploiting surface diffusion kinetics of W and S species adsorbed onto a substrate, a deterministic layer thickness control has also been achieved promoting the design of scalable synthesis routes.

  14. Which histological characteristics of basal cell carcinomas influence the quality of optical coherence tomography imaging?

    DEFF Research Database (Denmark)

    Mogensen, M.; Thrane, Lars; Jørgensen, Thomas Martini

    2009-01-01

    We explore how histopathology parameters influence OCT imaging of basal cell carcinomas (BCC) and address whether such parameters correlate with the quality of the recorded OCT images. Our results indicate that inflammation impairs OCT imaging and that sun-damaged skin can sometimes provide more...

  15. Toward a fusion of optical coherence tomography and hyperspectral imaging for poultry meat quality assessment

    Science.gov (United States)

    An emerging poultry meat quality concern is associated with chicken breast fillets having an uncharacteristically hard or rigid feel (called the wooden breast condition). The cause of the wooden breast condition is still largely unknown, and there is no single objective evaluation method or system k...

  16. A Simple Model of the Accommodating Lens of the Human Eye

    Science.gov (United States)

    Oommen, Vinay; Kanthakumar, Praghalathan

    2014-01-01

    The human eye is often discussed as optically equivalent to a photographic camera. The iris is compared with the shutter, the pupil to the aperture, and the retina to the film, and both have lens systems to focus rays of light. Although many similarities exist, a major difference between the two systems is the mechanism involved in focusing an…

  17. Lens aging in relation to nutritional determinants and possible risk factors for age-related cataract

    NARCIS (Netherlands)

    Berendschot, T.T.J.M.; Broekmans, W.M.R.; Klöpping-Ketelaars, I.A.A.; Kardinaal, A.F.M.; Poppel, G. van; Norren, D. van

    2002-01-01

    Objective: To investigate whether nutritional factors and possible risk factors for cataract influence the lens optical density (LOD). Design: Three hundred seventy-six subjects, aged 18 to 75 years, were recruited. In a cross-sectional design, serum was analyzed for lutein, zeaxanthin, vitamin C,

  18. Absorption coefficient of nearly transparent liquids measured using thermal lens spectrometry

    Directory of Open Access Journals (Sweden)

    H.Cabrera

    2006-01-01

    Full Text Available We use an optimized pump-probe mode-mismatched thermal lens scheme to determine the optical absorption coefficient and thermal diffusivity of ethanol, benzene, acetone, methanol, toluene and chloroform. In this scheme the excitation beam is focused in the presence of a collimated probe beam. The agreement between experimentally obtained results and values reported in the literature is good.

  19. Spectral and directional reflectance of the fovea in diabetes mellitus: Photoreceptor integrity, macular pigment and lens

    NARCIS (Netherlands)

    Zagers, N.P.A.; Pot, M.C.A.; Norren, D. van

    2005-01-01

    Our aim was to assess the integrity of the photoreceptors in the fovea, and to measure the optical density of the macular pigment and the eye lens in patients with diabetes mellitus, and to compare the results with those of a group of healthy subjects. The directional and spectral properties of the

  20. Geometric calibration of lens and filter distortions for multispectral filter-wheel cameras.

    Science.gov (United States)

    Brauers, Johannes; Aach, Til

    2011-02-01

    High-fidelity color image acquisition with a multispectral camera utilizes optical filters to separate the visible electromagnetic spectrum into several passbands. This is often realized with a computer-controlled filter wheel, where each position is equipped with an optical bandpass filter. For each filter wheel position, a grayscale image is acquired and the passbands are finally combined to a multispectral image. However, the different optical properties and non-coplanar alignment of the filters cause image aberrations since the optical path is slightly different for each filter wheel position. As in a normal camera system, the lens causes additional wavelength-dependent image distortions called chromatic aberrations. When transforming the multispectral image with these aberrations into an RGB image, color fringes appear, and the image exhibits a pincushion or barrel distortion. In this paper, we address both the distortions caused by the lens and by the filters. Based on a physical model of the bandpass filters, we show that the aberrations caused by the filters can be modeled by displaced image planes. The lens distortions are modeled by an extended pinhole camera model, which results in a remaining mean calibration error of only 0.07 pixels. Using an absolute calibration target, we then geometrically calibrate each passband and compensate for both lens and filter distortions simultaneously. We show that both types of aberrations can be compensated and present detailed results on the remaining calibration errors.