WorldWideScience

Sample records for lens multimode fiber

  1. Multimode optical fiber

    Science.gov (United States)

    Bigot-Astruc, Marianne; Molin, Denis; Sillard, Pierre

    2014-11-04

    A depressed graded-index multimode optical fiber includes a central core, an inner depressed cladding, a depressed trench, an outer depressed cladding, and an outer cladding. The central core has an alpha-index profile. The depressed claddings limit the impact of leaky modes on optical-fiber performance characteristics (e.g., bandwidth, core size, and/or numerical aperture).

  2. Rotational memory effect of a multimode fiber

    NARCIS (Netherlands)

    Amitonova, Lyubov V.; Mosk, Allard P.; Pinkse, Pepijn W. H.

    2015-01-01

    We demonstrate the rotational memory effect in a multimode fiber. Rotating the incident wavefront around the fiber core axis leads to a rotation of the resulting pattern of the fiber output without significant changes in the resulting speckle pattern. The rotational memory effect can be exploited

  3. Fiber-Optic Vibration Sensor Based on Multimode Fiber

    Directory of Open Access Journals (Sweden)

    I. Lujo

    2008-06-01

    Full Text Available The purpose of this paper is to present a fiberoptic vibration sensor based on the monitoring of the mode distribution in a multimode optical fiber. Detection of vibrations and their parameters is possible through observation of the output speckle pattern from the multimode optical fiber. A working experimental model has been built in which all used components are widely available and cheap: a CCD camera (a simple web-cam, a multimode laser in visible range as a light source, a length of multimode optical fiber, and a computer for signal processing. Measurements have shown good agreement with the actual frequency of vibrations, and promising results were achieved with the amplitude measurements although they require some adaptation of the experimental model. Proposed sensor is cheap and lightweight and therefore presents an interesting alternative for monitoring large smart structures.

  4. Multimode-Optical-Fiber Imaging Probe

    Science.gov (United States)

    Jackson, Deborah

    2000-01-01

    Currently, endoscopic surgery uses single-mode fiber-bundles to obtain in vivo image information inside orifices of the body. This limits their use to the larger natural bodily orifices and to surgical procedures where there is plenty of room for manipulation. The knee joint, for example can be easily viewed with a fiber optic viewer, but joints in the finger cannot. However, there are a host of smaller orifices where fiber endoscopy would play an important role if a cost effective fiber probe were developed with small enough dimensions (fibers and analytically demonstrates that the concept is sound. The proof of concept draws upon earlier works that concentrated on image recovery after two-way transmission through a multimode fiber as well as work that demonstrated the recovery of images after one-way transmission through a multimode fiber. Both relied on generating a phase conjugated wavefront which was predistorted with the characteristics of the fiber. The described approach also relies on generating a phase conjugated wavefront, but utilizes two fibers to capture the image at some intermediate point (accessible by the fibers, but which is otherwise visually unaccessible).

  5. Fiber Optic Pressure Sensor using Multimode Interference

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz-Perez, V I; Sanchez-Mondragon, J J [INAOE, Apartado Postal 51 y 216, Puebla 72000 (Mexico); Basurto-Pensado, M A [CIICAp, Universidad Autonoma del Estado de Morelos (Mexico); LiKamWa, P [CREOL, University of Central Florida, Orlando, FL 32816 (United States); May-Arrioja, D A, E-mail: iruiz@inaoep.mx, E-mail: mbasurto@uaem.mx, E-mail: delta_dirac@hotmail.com, E-mail: daniel_may_arrioja@hotmail.com [UAT Reynosa Rodhe, Universidad Autonoma de Tamaulipas (Mexico)

    2011-01-01

    Based on the theory of multimode interference (MMI) and self-image formation, we developed a novel intrinsic optical fiber pressure sensor. The sensing element consists of a section of multimode fiber (MMF) without cladding spliced between two single mode fibers (SMF). The MMI pressure sensor is based on the intensity changes that occur in the transmitted light when the effective refractive index of the MMF is changed. Basically, a thick layer of Polydimethylsiloxane (PDMS) is placed in direct contact with the MMF section, such that the contact area between the PDMS and the fiber will change proportionally with the applied pressure, which results in a variation of the transmitted light intensity. Using this configuration, a good correlation between the measured intensity variations and the applied pressure is obtained. The sensitivity of the sensor is 3 {mu}V/psi, for a range of 0-60 psi, and the maximum resolution of our system is 0.25 psi. Good repeatability is also observed with a standard deviation of 0.0019. The key feature of the proposed pressure sensor is its low fabrication cost, since the cost of the MMF is minimal.

  6. Photonic lantern with multimode fibers embedded

    Science.gov (United States)

    Yu, Hai-Jiao; Yan, Qi; Huang, Zong-Jun; Tian, He; Jiang, Yu; Liu, Yong-Jun; Zhang, Jian-Zhong; Sun, Wei-Min

    2014-08-01

    A photonic lantern is studied which is formed by seven multimode fibers inserted into a pure silica capillary tube. The core of the tapered end has a uniform refractive index because the polymer claddings are removed before the fibers are inserted. Consequently, the light distribution is also uniform. Two theories describing a slowly varying waveguide and multimode coupling are used to analyze the photonic lantern. The transmission loss decreases as the length of the tapered part increases. For a device with a taper length of 3.4 cm, the loss is about 1.06 dB on average for light propagating through the taper from an inserted fiber to the tapered end and 0.99 dB in the reverse direction. For a device with a taper length of 0.7 cm, the two loss values are 2.63 dB and 2.53 dB, respectively. The results show that it is possible to achieve a uniform light distribution with the tapered end and a low-loss transmission in the device if parameters related to the lantern are reasonably defined.

  7. Photonic lantern with multimode fibers embedded

    International Nuclear Information System (INIS)

    Yu Hai-Jiao; Yan Qi; Huang Zong-Jun; Tian He; Jiang Yu; Liu Yong-Jun; Zhang Jian-Zhong; Sun Wei-Min

    2014-01-01

    A photonic lantern is studied which is formed by seven multimode fibers inserted into a pure silica capillary tube. The core of the tapered end has a uniform refractive index because the polymer claddings are removed before the fibers are inserted. Consequently, the light distribution is also uniform. Two theories describing a slowly varying waveguide and multimode coupling are used to analyze the photonic lantern. The transmission loss decreases as the length of the tapered part increases. For a device with a taper length of 3.4 cm, the loss is about 1.06 dB on average for light propagating through the taper from an inserted fiber to the tapered end and 0.99 dB in the reverse direction. For a device with a taper length of 0.7 cm, the two loss values are 2.63 dB and 2.53 dB, respectively. The results show that it is possible to achieve a uniform light distribution with the tapered end and a low-loss transmission in the device if parameters related to the lantern are reasonably defined. (research papers)

  8. Nineteen-port photonic lantern with multimode delivery fiber

    DEFF Research Database (Denmark)

    Noordegraaf, Danny; Skovgaard, Peter M. W.; Sandberg, Rasmus Kousholt

    2012-01-01

    We demonstrate efficient multimode (MM) to single-mode (SM) conversion in a 19-port photonic lantern with a 50 μm core MM delivery fiber. The photonic lantern can be used within the field of astrophotonics for coupling MM starlight to an ensemble of SM fibers in order to perform fiber-Bragg-grati......We demonstrate efficient multimode (MM) to single-mode (SM) conversion in a 19-port photonic lantern with a 50 μm core MM delivery fiber. The photonic lantern can be used within the field of astrophotonics for coupling MM starlight to an ensemble of SM fibers in order to perform fiber......-Bragg-grating-based spectral filtering. An MM delivery fiber spliced to the photonic lantern offers the advantage that the delivery fiber guides the light from the focal plane of the telescope to the splitter. Therefore, it is no longer necessary to have the splitter mounted directly in the focal plane of the telescope...

  9. Object recognition through a multi-mode fiber

    Science.gov (United States)

    Takagi, Ryosuke; Horisaki, Ryoichi; Tanida, Jun

    2017-04-01

    We present a method of recognizing an object through a multi-mode fiber. A number of speckle patterns transmitted through a multi-mode fiber are provided to a classifier based on machine learning. We experimentally demonstrated binary classification of face and non-face targets based on the method. The measurement process of the experimental setup was random and nonlinear because a multi-mode fiber is a typical strongly scattering medium and any reference light was not used in our setup. Comparisons between three supervised learning methods, support vector machine, adaptive boosting, and neural network, are also provided. All of those learning methods achieved high accuracy rates at about 90% for the classification. The approach presented here can realize a compact and smart optical sensor. It is practically useful for medical applications, such as endoscopy. Also our study indicated a promising utilization of artificial intelligence, which has rapidly progressed, for reducing optical and computational costs in optical sensing systems.

  10. Real-time resilient focusing through a bending multimode fiber.

    Science.gov (United States)

    Caravaca-Aguirre, Antonio M; Niv, Eyal; Conkey, Donald B; Piestun, Rafael

    2013-05-20

    Multimode optical fibers are attractive for biomedical and sensing applications because they possess a small cross section and can bend over small radii of curvature. However, mode phase-velocity dispersion and random mode coupling change with bending, temperature, and other perturbations, producing scrambling interference among propagating modes; hence preventing its use for focusing or imaging. To tackle this problem we introduce a system capable of re-focusing light through a multimode fiber in 37ms, one order of magnitude faster than demonstrated in previous reports. As a result, the focus spot can be maintained during significant bending of the fiber, opening numerous opportunities for endoscopic imaging and energy delivery applications. We measure the transmission matrix of the fiber by projecting binary-amplitude computer generated holograms using a digital micro-mirror device controlled by a field programmable gate array. The system shows two orders of magnitude enhancements of the focus spot relative to the background.

  11. Parallel Information Processing (Image Transmission Via Fiber Bundle and Multimode Fiber

    Science.gov (United States)

    Kukhtarev, Nicholai

    2003-01-01

    Growing demand for visual, user-friendly representation of information inspires search for the new methods of image transmission. Currently used in-series (sequential) methods of information processing are inherently slow and are designed mainly for transmission of one or two dimensional arrays of data. Conventional transmission of data by fibers requires many fibers with array of laser diodes and photodetectors. In practice, fiber bundles are also used for transmission of images. Image is formed on the fiber-optic bundle entrance surface and each fiber transmits the incident image to the exit surface. Since the fibers do not preserve phase, only 2D intensity distribution can be transmitted in this way. Each single mode fiber transmit only one pixel of an image. Multimode fibers may be also used, so that each mode represent different pixel element. Direct transmission of image through multimode fiber is hindered by the mode scrambling and phase randomization. To overcome these obstacles wavelength and time-division multiplexing have been used, with each pixel transmitted on a separate wavelength or time interval. Phase-conjugate techniques also was tested in, but only in the unpractical scheme when reconstructed image return back to the fiber input end. Another method of three-dimensional imaging over single mode fibers was demonstrated in, using laser light of reduced spatial coherence. Coherence encoding, needed for a transmission of images by this methods, was realized with grating interferometer or with the help of an acousto-optic deflector. We suggest simple practical holographic method of image transmission over single multimode fiber or over fiber bundle with coherent light using filtering by holographic optical elements. Originally this method was successfully tested for the single multimode fiber. In this research we have modified holographic method for transmission of laser illuminated images over commercially available fiber bundle (fiber endoscope, or

  12. Ball Lens Fiber Optic Sensor based Smart Handheld Microsurgical Instrument.

    Science.gov (United States)

    Song, Cheol; Gehlbach, Peter L; Kang, Jin U

    2013-03-20

    During freehand performance of vitreoretinal microsurgery the surgeon must perform precise and stable maneuvers that achieve surgical objectives and avoid surgical risk. Here, we present an improved smart handheld microsurgical tool which is based on a ball lens fiber optic sensor that utilizes common path swept source optical coherence tomography. Improvements include incorporation of a ball lens single mode fiber optic probe that increases the working angle of the tool to greater than 45 degrees; and increases the magnitude of the distance sensing signal through water. Also presented is a cutting function with an improved ergonomic design.

  13. Gradient-index optical fiber lens for efficient fiber-to-chip coupling.

    Science.gov (United States)

    Melkonyan, Henrik; Al Qubaisi, Kenaish; Sloyan, Karen; Khilo, Anatol; Dahlem, Marcus S

    2017-06-12

    A gradient-index optical fiber lens is proposed and fabricated on the tip of a single-mode fiber using focused ion beam milling. Second-order effective medium theory is used to design a gradual change in the fill factor, which ensures a parabolic effective refractive index distribution. The proposed fiber lens design is simulated via the three-dimensional finite-difference time-domain method, and demonstrated through confocal optical measurements. At a wavelength of 1550 nm, the fabricated lenses focus a 10.4 μm mode field diameter exiting the fiber into spot sizes between 3-5 μm, located 4-6 μm away from the fiber tip. Direct coupling into a silicon-on-insulator chip is also demonstrated, where the fabricated gradient-index lens has a coupling efficiency comparable to a commercial lensed fiber.

  14. Reconfigurable optical interconnection network for multimode optical fiber sensor arrays

    Science.gov (United States)

    Chen, R. T.; Robinson, D.; Lu, H.; Wang, M. R.; Jannson, T.; Baumbick, R.

    1992-01-01

    A single-source, single-detector architecture has been developed to implement a reconfigurable optical interconnection network multimode optical fiber sensor arrays. The network was realized by integrating LiNbO3 electrooptic (EO) gratings working at the Raman Na regime and a massive fan-out waveguide hologram (WH) working at the Bragg regime onto a multimode glass waveguide. The glass waveguide utilized the whole substrate as a guiding medium. A 1-to-59 massive waveguide fan-out was demonstrated using a WH operating at 514 nm. Measured diffraction efficiency of 59 percent was experimentally confirmed. Reconfigurability of the interconnection was carried out by generating an EO grating through an externally applied electric field. Unlike conventional single-mode integrated optical devices, the guided mode demonstrated has an azimuthal symmetry in mode profile which is the same as that of a fiber mode.

  15. SBS [stimulated Brillouin scattering] pulse distortion in multimode optical fibers

    International Nuclear Information System (INIS)

    Smith, J.R.; Hawkins, R.J.; Laumann, C.W.; Hatch, J.

    1989-01-01

    We have observed sever temporal-pulse-shape distortion due to stimulated Brillouin scattering (SBS) in multimode optical fibers used to diagnose 351 m laser pulses on the Nova laser system. Our measurements can be fit by a basic model of SBS and provide a clear indication of the intensity and temporal regimes where significant SBS-induced temporal-pulse-shape distortion can be avoided. 15 refs., 3 figs., 1 tab

  16. All-fiber multimode interference micro-displacement sensor

    International Nuclear Information System (INIS)

    Antonio-Lopez, J E; LiKamWa, P; Sanchez-Mondragon, J J; May-Arrioja, D A

    2013-01-01

    We report an all-fiber micro-displacement sensor based on multimode interference (MMI) effects. The micro-displacement sensor consists of a segment of No-Core multimode fiber (MMF) with one end spliced to a segment of single mode fiber (SMF) which acts as the input. The other end of the MMF and another SMF are inserted into a capillary ferrule filled with index matching liquid. Since the refractive index of the liquid is higher than that of the ferrule, a liquid MMF with a diameter of 125 µm is formed between the fibers inside the ferrule. When the fibers are separated this effectively increases the length of the MMF. Since the peak wavelength response of MMI devices is very sensitive to changes in the MMF's length, this can be used to detect micro-displacements. By measuring spectral changes we have obtained a sensing range of 3 mm with a sensitivity of 25 nm mm −1 and a resolution of 20 µm. The sensor can also be used to monitor small displacements by using a single wavelength to interrogate the transmission of the MMI device close to the resonance peak. Under this latter regime we were able to obtain a sensitivity of 7000 mV mm −1 and a sensing range of 100 µm, with a resolution up to 1 µm. The simplicity and versatility of the sensor make it very suitable for many diverse applications. (paper)

  17. Aberrations of the point spread function of a multimode fiber due to partial mode excitation

    NARCIS (Netherlands)

    Descloux, Adrien; Amitonova, Lyubov; Pinkse, Pepijn Willemszoon Harry

    2016-01-01

    We investigate the point spread function of a multimode fiber. The distortion of the focal spot created on the fiber output facet is studied for a variety of the parameters. We develop a theoretical model of wavefront shaping through a multimode fiber and use it to confirm our experimental results

  18. Multimode-singlemode-multimode optical fiber sensor coated with novolac resin for detecting liquid phase alcohol

    Science.gov (United States)

    Marfu'ah, Amalia, Niza Rosyda; Hatta, Agus Muhamad; Pratama, Detak Yan

    2018-04-01

    Alcohol sensor based on multimode-singlemode-multimode (MSM) optical fiber with novolac resin as the external medium is proposed and demonstrated experimentally. Novolac resin swells when it is exposed by the alcohol. This effect causes a change in the polymer density leading to the refractive index's variation. The transmission light of the sensor depends on the refractive index of external medium. Based on the results, alcohol sensor based on MSM optical fiber structure using novolac resin has a higher sensitivity compared to the sensor without using novolac resin in the mixture of alcohol and distilled water. Alcohol sensor based on MSM optical fiber structure using novolac resin in the mixture of alcohol and distilled water with a singlemode fiber length of 5 mm has a sensitivity of 0.028972 dBm per % V/V, and in the mixture of alcohol and sugar solution of 10% w/w has a sensitivity of 0.005005 dBm per % V/V.

  19. Comparison of gamma, neutron and proton irradiations of multimode fibers

    International Nuclear Information System (INIS)

    Gingerich, M.E.; Dorsey, K.L.; Askins, C.G.; Friebele, E.J.

    1987-01-01

    The effects of pure gamma, pure proton, and mixed neutron-gamma irradiation fields on a set of both pure and doped silica core multimode fibers have been investigated. Only slight differences are found in the radiation response of pure and doped silica core fibers exposed to gamma or mixed neutron-gamma fields, indicating that Co-60 sources can be used to simulate the effects of the mixed field (except in the case of a pure neutron environment). Although it is noted that neither mix field nor gamma sources adequately simulate the effects of proton irradiation of doped silica core fibers, a good correspondence is found in the case of the pure silica core waveguide. 13 references

  20. High numerical aperture imaging by using multimode fibers with micro-fabricated optics

    KAUST Repository

    Bianchi, Silvio

    2014-01-01

    Controlling light propagation into multimode optical fibers through spatial light modulators provides highly miniaturized endoscopes and optical micromanipulation probes. We increase the numerical aperture up to nearly 1 by micro-optics fabricated on the fiber-end.

  1. Coexistence of collapse and stable spatiotemporal solitons in multimode fibers

    Science.gov (United States)

    Shtyrina, Olga V.; Fedoruk, Mikhail P.; Kivshar, Yuri S.; Turitsyn, Sergei K.

    2018-01-01

    We analyze spatiotemporal solitons in multimode optical fibers and demonstrate the existence of stable solitons, in a sharp contrast to earlier predictions of collapse of multidimensional solitons in three-dimensional media. We discuss the coexistence of blow-up solutions and collapse stabilization by a low-dimensional external potential in graded-index media, and also predict the existence of stable higher-order nonlinear waves such as dipole-mode spatiotemporal solitons. To support the main conclusions of our numerical studies we employ a variational approach and derive analytically the stability criterion for input powers for the collapse stabilization.

  2. Performance characterization of the IEEE 802.11 signal transmission over a multimode fiber PON

    Science.gov (United States)

    Maksymiuk, L.; Siuzdak, J.

    2014-11-01

    In this paper there are presented measurements concerning performance analysis of the IEEE 802.11 signal distribution over multimode fiber based passive optical network. In the paper there are addressed three main sources of impairments: modal noise, frequency response fluctuation of the multimode fiber and non-linear distortion of the signal in the receiver.

  3. Aberrations of the point spread function of a multimode fiber due to partial mode excitation

    Science.gov (United States)

    Descloux, Adrien; Amitonova, Lyubov V.; Pinkse, Pepijn W. H.

    2016-08-01

    We investigate the point spread function of a multimode fiber. The distortion of the focal spot created on the fiber output facet is studied for a variety of the parameters. We develop a theoretical model of wavefront shaping through a multimode fiber and use it to confirm our experimental results and analyze the nature of the focal distortions. We show that aberration-free imaging with a large field of view can be achieved by using an appropriate number of segments on the spatial light modulator during the wavefront-shaping procedure. The results describe aberration limits for imaging with multimode fibers as in, e.g., microendoscopy.

  4. All-Fiber Laser Curvature Sensor Using an In-Fiber Modal Interferometer Based on a Double Clad Fiber and a Multimode Fiber Structure

    Science.gov (United States)

    Durán-Sánchez, Manuel; Prieto-Cortés, Patricia; Salceda-Delgado, Guillermo; Castillo-Guzmán, Arturo A.; Selvas-Aguilar, Romeo; Ibarra-Escamilla, Baldemar; Kuzin, Evgeny A.

    2017-01-01

    An all-fiber curvature laser sensor by using a novel modal interference in-fiber structure is proposed and experimentally demonstrated. The in-fiber device, fabricated by fusion splicing of multimode fiber and double-clad fiber segments, is used as wavelength filter as well as the sensing element. By including a multimode fiber in an ordinary modal interference structure based on a double-clad fiber, the fringe visibility of the filter transmission spectrum is significantly increased. By using the modal interferometer as a curvature sensitive wavelength filter within a ring cavity erbium-doped fiber laser, the spectral quality factor Q is considerably increased. The results demonstrate the reliability of the proposed curvature laser sensor with advantages of robustness, ease of fabrication, low cost, repeatability on the fabrication process and simple operation. PMID:29182527

  5. Ultra-broadband indoor optical wireless communication system with multimode fiber.

    Science.gov (United States)

    Wang, Ke; Nirmalathas, Ampalavanapillai; Lim, Christina; Skafidas, Efstratios

    2012-05-01

    In this paper we experimentally demonstrate an ultra-broadband indoor full-duplex WDM optical wireless communication system with multimode fiber. The multimode fiber is used because it is employed in most of the already installed in-building fiber distribution networks. Simultaneous error-free (BER<10(-9)) transmission of 4×12.5 Gbps downlink and 800 Mbps uplink has been successfully demonstrated. The experimental results show that, although the use of multimode fiber will induce ~2.4 cm reduction in the maximum error-free beam footprint in the downlink, the bit rate of the uplink can be much higher compared to the system with single-mode fiber.

  6. Highly sensitive curvature sensor based on asymmetrical twin core fiber and multimode fiber

    Science.gov (United States)

    Wu, Yue; Pei, Li; Jin, Wenxing; Jiang, Youchao; Yang, Yuguang; Shen, Ya; Jian, Shuisheng

    2017-07-01

    A highly sensitive curvature sensor based on asymmetrical twin core fiber (TCF) and multimode fiber (MMF) is proposed and experimentally demonstrated. By applying the coupled-mode theory and equivalent refractive index model, we theoretically analyze the uncoupled feature of the TCF and the relationship between peak wavelength and the curvature. Two segments of MMF used as beam splitter and combiner are embedded on the two ends of the TCF, and the extinction ratio of the comb transmission spectrum is about 15 dB. The experimental result shows that the curvature sensitivity of the sensor can be achieved as high as 103.35 nm/m-1 ranging from 0.24 m-1 to 0.6 m-1, and the strain sensitivity is up to -4.01 pm/με in the range from 0 μεto 1400 με. The simultaneous detection of the curvature and strain can be realized. The temperature sensitivity is 0.431 nm/°C in the range from 40 °C to 70 °C. This fiber sensor exhibits the advantages of low cost, easy and repeated fabrication, and high sensitivity.

  7. Optical access network using centralized light source, single-mode fiber + broad wavelength window multimode fiber

    Science.gov (United States)

    Yam, Scott S.-H.; Kim, Jaedon; Gutierrez, David; Achten, Frank

    2006-08-01

    Access networks based on a single-mode fiber (SMF) using a centralized light source (CLS) have attracted much attention recently due to their wavelength management flexibility and potential for cost reduction at customers' premises. Future networks, in addition, are likely to contain segments of multimode fiber (MMF), whose core dimension is relatively large in comparison with its single-mode counterpart, substantially reducing fiber alignment constraints and the subsequent network construction and installation cost. In this study, a CLS-based passive optical network (PON) is proposed, which will use a new generation of high-performance MMF optimized for a broad wavelength transmission window spanning from 1300to1550 nm, with a bandwidth distance product (BDP) of 40 Gbit/s-km. The proposed architecture is implemented in a test bed, and its performance is verified by bit error ratio (BER) measurement. Results show that we can implement high-performance CLS-based PONs containing both an SMF and an MMF infrastructure, simultaneously.

  8. Focusing and imaging with increased numerical apertures through multimode fibers with micro-fabricated optics

    KAUST Repository

    Bianchi, Silvio

    2013-01-01

    The use of individual multimode optical fibers in endoscopy applications has the potential to provide highly miniaturized and noninvasive probes for microscopy and optical micromanipulation. A few different strategies have been proposed recently, but they all suffer from intrinsically low resolution related to the low numerical aperture of multimode fibers. Here, we show that two-photon polymerization allows for direct fabrication of micro-optics components on the fiber end, resulting in an increase of the numerical aperture to a value that is close to 1. Coupling light into the fiber through a spatial light modulator, we were able to optically scan a submicrometer spot (300 nm FWHM) over an extended region, facing the opposite fiber end. Fluorescence imaging with improved resolution is also demonstrated. © 2013 Optical Society of America.

  9. Performance comparison of pre-, boost-, and inline-multimode erbium-doped fiber amplifier configurations to boost mode-division multiplexed multimode fiber link

    Science.gov (United States)

    Gupta, Rajan; Kaler, Rajinder Singh

    2016-05-01

    The performance of 3×3, 4×4, 5×5, and 6×6 optical multi-input multioutput (MIMO) mode-division multiplexed multimode fiber (MMF) systems has been investigated using pre-, boost-, and inline-multimode erbium-doped fiber amplifier configuration methods with LPlm (linearly polarized) modes. The outcome of these configurations has been compared in terms of quality factor (Q-factor) and bit error rate (BER). It is reported that inline-configuration provides best results for all MIMO mode-division multiplexing (MDM) systems covering transmission distance of 100 km with acceptable BER (10 dB) over MMF link to boost performance of MDM system.

  10. Phase optimization of a multimode fiber laser beam with SPGD algorithm

    Science.gov (United States)

    Zhang, Chi; Liu, Wenguang; Zhou, Qiong

    2017-05-01

    Compared with single-mode laser, multimode fiber laser can achieve higher output power. But with distorted phase distribution, the beam quality of multimode laser is poor. To improve the beam quality of multimode laser, phase optimization of multimode laser based on the stochastic parallel gradient descent (SPGD) algorithm is presented in this paper. To realize the phase control of beam, a multiple pixels screen used as phase correction device is added in the output light path. In the SPGD algorithm, the pixels of phase correction screen are regarded as the controlled variables, power in the bucket (PIB) of the far field is used as the evaluation function. By changing the phase modulation of each pixel, the optimal PIB is obtained by this algorithm, and the beam quality is improved. The optimization of high-order mode beam and multimode beam are calculated respectively. The multimode beam includes two modes: TEM00 and TEM21 and the proportion of output power is 1:1. The results show that the PIB of the single high-order mode beam is improved from 0.02 to 0.70 after 30000 times iteration., the multimode laser is improved from 0.02 to 0.40 after 20000 times iteration. According to the result, parameters of the algorithm are adjusted to improve efficiency and practicability.

  11. Spatial Frequency Multiplexing of Fiber-Optic Interferometric Refractive Index Sensors Based on Graded-Index Multimode Fibers

    Science.gov (United States)

    Liu, Li; Gong, Yuan; Wu, Yu; Zhao, Tian; Wu, Hui-Juan; Rao, Yun-Jiang

    2012-01-01

    Fiber-optic interferometric sensors based on graded-index multimode fibers have very high refractive-index sensitivity, as we previously demonstrated. In this paper, spatial-frequency multiplexing of this type of fiber-optic refractive index sensors is investigated. It is estimated that multiplexing of more than 10 such sensors is possible. In the multiplexing scheme, one of the sensors is used to investigate the refractive index and temperature responses. The fast Fourier transform (FFT) of the combined reflective spectra is analyzed. The intensity of the FFT spectra is linearly related with the refractive index and is not sensitive to the temperature.

  12. 100G shortwave wavelength division multiplexing solutions for multimode fiber data links

    DEFF Research Database (Denmark)

    Cimoli, Bruno; Estaran Tolosa, Jose Manuel; Rodes Lopez, Guillermo Arturo

    2016-01-01

    We investigate an alternative 100G solution for optical short-range data center links. The presented solution adopts wavelength division multiplexing technology to transmit four channels of 25G over a multimode fiber. A comparative performance analysis of the wavelength-grid selection for the wav...

  13. Link Design Rules for Cost-Effective Short-Range Radio Over Multimode Fiber Systems

    DEFF Research Database (Denmark)

    Visani, Davide; Tartarini, Giovanni; Petersen, Martin Nordal

    2010-01-01

    Referring to short-range radio over multimode fiber links, we find out important guidelines for the realization of cost-effective intensity modulated directly detected systems. Since the quality of today's connectors is considerably higher than in the past, we demonstrate that two important...... for short-range applications, where the transmittable bandwidth does not constitute the main limitation....

  14. Objective-lens-free Fiber-based Position Detection with Nanometer Resolution in a Fiber Optical Trapping System.

    Science.gov (United States)

    Ti, Chaoyang; Ho-Thanh, Minh-Tri; Wen, Qi; Liu, Yuxiang

    2017-10-13

    Position detection with high accuracy is crucial for force calibration of optical trapping systems. Most existing position detection methods require high-numerical-aperture objective lenses, which are bulky, expensive, and difficult to miniaturize. Here, we report an affordable objective-lens-free, fiber-based position detection scheme with 2 nm spatial resolution and 150 MHz bandwidth. This fiber based detection mechanism enables simultaneous trapping and force measurements in a compact fiber optical tweezers system. In addition, we achieved more reliable signal acquisition with less distortion compared with objective based position detection methods, thanks to the light guiding in optical fibers and small distance between the fiber tips and trapped particle. As a demonstration of the fiber based detection, we used the fiber optical tweezers to apply a force on a cell membrane and simultaneously measure the cellular response.

  15. Color digital holography using speckle illumination by means of a multi-mode fiber

    Science.gov (United States)

    Funamizu, Hideki; Shimoma, Shohei; Aizu, Yoshihisa

    2014-02-01

    We present color digital holography using speckle illumination by means of a multi-mode fiber. In this technique, speckle fields emitted from the fiber are used as both a reference wave and a wavefront illuminating an object. For three wavelengths, the interference patterns of two coherent waves are recorded as digital holograms on a CCD camera. A speckle method is used for suppressing DC terms and reducing a twin image in an in-line color digital holography. The speckle fields are changed by vibrating the multi-mode fiber using a vibrator, and a number of holograms are acquired to average reconstructed images. The dependence of the averaged number of holograms on color quality of reconstructed images is evaluated by chromaticity coordinates and color differences in colorimetry.

  16. Investigation of Laser Beam Combining and Clean-Up via Seeded Stimulated Brillouin Scattering in Multimode Optical Fibers

    National Research Council Canada - National Science Library

    Choi, Bryan

    2000-01-01

    .... Beam combining in multimode fibers via SBS is being considered as a method of combining low power laser beams into a single beam having higher power and superior spatial coherence for applications...

  17. A Review of Multimode Interference in Tapered Optical Fibers and Related Applications

    Science.gov (United States)

    Wang, Pengfei; Zhao, Haiyan; Wang, Xianfan; Brambilla, Gilberto

    2018-01-01

    In recent years, tapered optical fibers (TOFs) have attracted increasing interest and developed into a range of devices used in many practical applications ranging from optical communication, sensing to optical manipulation and high-Q resonators. Compared with conventional optical fibers, TOFs possess a range of unique features, such as large evanescent field, strong optical confinement, mechanical flexibility and compactness. In this review, we critically summarize the multimode interference in TOFs and some of its applications with a focus on our research project undertaken at the Optoelectronics Research Centre of the University of Southampton in the United Kingdom. PMID:29538333

  18. Effect of acoustic waveguide properties on the Brillouin gain spectrum in multi-mode fibers

    Science.gov (United States)

    Ke, Wei-Wei; Wang, Xiao-Jun; Tang, Xuan

    2015-02-01

    With a recent developed mode-coupling model, the Brillouin gain spectra (BGS) of multi-mode fibers (MMF) are investigated and compared with the corresponding experiment. It is found that the calculation results are coincident well with the experiment data. Furthermore, the BGS are found to be very sensitive to the index fluctuation. Such phenomenon is demonstrated by introducing a small index hump or dip in the center of the fiber core. And it can be explained by that the index fluctuation may influence the acoustic mode greatly.

  19. Unique method to determine the differential mode delay of specialty multimode fibers

    Science.gov (United States)

    Wittig, Marcus; Baselt, Tobias; Nelsen, Bryan L.; Hartmann, Peter

    2017-05-01

    We developed an experimental setup for the determination of the differential mode delay (DMD) in fibers. This unique method of measurement is the basis for the characterization of specialty fibers including properties such as the chromatic dispersion, the fiber geometry and the DMD. These fibers have their application in the nearinfrared and mid-infrared regime. Examples of uses of such fibers are supercontinuum light sources and high power lasers. Different modifications of these multimode fibers are applicable in extreme environments or for standard beam delivery over long distances. The exact knowledge of parameters such as the DMD is necessary to generate light sources with ether high energy, high intensity or high power or to analyze transmitted information when the fiber is used in a configuration for communication. For the most precise measurement of DMD, we investigated a new type of method. It is capable of measuring the modal dispersion in two different ways. The first way is the standard transversal measurement, where the launching condition is altered by moving the radial position of the injected pulse while maintaining a zero-angle launching condition. The second way involves changing the launching angle into the fiber. This is done to get the most precise value for the DMD. Also, using a supercontinuum light source for the injection pulse, it is possible to vary the wavelength to be able to measure near the zero dispersion wavelength in order to investigate the effects of the chromatic dispersion.

  20. Half-ball lens couples a beveled fiber probe for depth-resolved spectroscopy: Monte Carlo simulations.

    Science.gov (United States)

    Jaillon, Franck; Zheng, Wei; Huang, Zhiwei

    2008-06-10

    In this study, we propose a beveled fiber-optic probe coupled with a half-ball lens for improving the depth-resolved fluorescence measurements of epithelial tissue. The Monte Carlo (MC) simulation results show that for a given excitation-collection fiber separation, the probe design with a bevel-angled collection fiber is more sensitive to detect fluorescence photons emitted from the shallow layer of tissue, whereas the flat-tip collection fiber is in favor of probing fluorescence photons originating from deeper tissue areas. This compact half-ball lens-beveled fiber probe design has the potential to facilitate the depth-resolved fluorescence detection of epithelial tissue.

  1. Multimodality

    DEFF Research Database (Denmark)

    Buhl, Mie

    2010-01-01

    on their teaching and learning situations. The choices they make involve e-learning resources like videos, social platforms and mobile devices, not just as digital artefacts we interact with, but the entire practice of using digital media. In a life-long learning perspective, multimodality is potentially very......In this paper, I address an ongoing discussion in Danish E-learning research about how to take advantage of the fact that digital media facilitate other communication forms than text, so-called ‘multimodal' communication, which should not be confused with the term ‘multimedia'. While multimedia...... useful for developing pedagogies where a synergy of different symbol systems facilitates new and flexible learning situations that can meet different needs of different learners. The present paper includes an example from a Danish university program...

  2. Refractive index sensors based on the fused tapered special multi-mode fiber

    Science.gov (United States)

    Fu, Xing-hu; Xiu, Yan-li; Liu, Qin; Xie, Hai-yang; Yang, Chuan-qing; Zhang, Shun-yang; Fu, Guang-wei; Bi, Wei-hong

    2016-01-01

    In this paper, a novel refractive index (RI) sensor is proposed based on the fused tapered special multi-mode fiber (SMMF). Firstly, a section of SMMF is spliced between two single-mode fibers (SMFs). Then, the SMMF is processed by a fused tapering machine, and a tapered fiber structure is fabricated. Finally, a fused tapered SMMF sensor is obtained for measuring external RI. The RI sensing mechanism of tapered SMMF sensor is analyzed in detail. For different fused tapering lengths, the experimental results show that the RI sensitivity can be up to 444.517 81 nm/RIU in the RI range of 1.334 9—1.347 0. The RI sensitivity is increased with the increase of fused tapering length. Moreover, it has many advantages, including high sensitivity, compact structure, fast response and wide application range. So it can be used to measure the solution concentration in the fields of biochemistry, health care and food processing.

  3. Compact multimode fiber beam-shaping system based on GPU accelerated digital holography.

    Science.gov (United States)

    Plöschner, Martin; Čižmár, Tomáš

    2015-01-15

    Real-time, on-demand, beam shaping at the end of the multimode fiber has recently been made possible by exploiting the computational power of rapidly evolving graphics processing unit (GPU) technology [Opt. Express 22, 2933 (2014)]. However, the current state-of-the-art system requires the presence of an acousto-optic deflector (AOD) to produce images at the end of the fiber without interference effects between neighboring output points. Here, we present a system free from the AOD complexity where we achieve the removal of the undesired interference effects computationally using GPU implemented Gerchberg-Saxton and Yang-Gu algorithms. The GPU implementation is two orders of magnitude faster than the CPU implementation which allows video-rate image control at the distal end of the fiber virtually free of interference effects.

  4. OptoCeramic-Based High Speed Fiber Multiplexer for Multimode Fiber, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — A fiber-based fixed-array laser transmitter can be combined with a fiber-arrayed detector to create the next-generation NASA array LIDAR systems. High speed optical...

  5. Ultrathin SWCNT Films Enabled Multi-modal Fiber Sensors

    Science.gov (United States)

    2014-09-30

    agarose  slab  was carefully placed into the electrophoresis chamber (17.5 cm × 26.5  cm gel tank, E1015‐10‐GT ‐ VMR® Midi plus Horizontal Electrophoresis...piezoresistive sensitivity with GF of ‐0.25 ± 0.029.  To  test  the  long‐term  durability   of  the  SWCNT‐FibSen  sensor,  an  epoxy/glass  fiber  laminate...sensitivity.  The  excellent  durability   of  SWCNT‐FibSen  sensors warrants  their  future applications as embedded  sensing elements  for  SHM of high

  6. Brightness enhancement of a multi-mode ribbon fiber using transmitting Bragg gratings

    Science.gov (United States)

    Anderson, B. M.; Venus, G.; Ott, D.; Divliansky, I.; Dawson, J. W.; Drachenberg, D. R.; Messerly, M. J.; Pax, P. H.; Tassano, J. B.; Glebov, L. B.

    2015-03-01

    Increasing the dimensions of a waveguide provides the simplest means of reducing detrimental nonlinear effects, but such systems are inherently multi-mode, reducing the brightness of the system. Furthermore, using rectangular dimensions allows for improved heat extraction, as well as uniform temperature profile within the core. We propose a method of using the angular acceptance of a transmitting Bragg grating (TBG) to filter the fundamental mode of a fiber laser resonator, and as a means to increase the brightness of multi-mode fiber laser. Numerical modeling is used to calculate the diffraction losses needed to suppress the higher order modes in a laser system with saturable gain. The model is tested by constructing an external cavity resonator using an ytterbium doped ribbon fiber with core dimensions of 107.8μm by 8.3μm as the active medium. We show that the TBG increases the beam quality of the system from M2 = 11.3 to M2 = 1.45, while reducing the slope efficiency from 76% to 53%, overall increasing the brightness by 5.1 times.

  7. Multimodality

    DEFF Research Database (Denmark)

    Buhl, Mie

    and learning situations. The choices they make involve E-learning resources like videos, social platforms and mobile devices, not just as digital artefacts we interact with, but the entire practice of using digital media. In a life-long learning perspective, multimodality is potentially very useful......In this paper, I address an ongoing discussion in Danish E-learning research about how to take advantage of the fact that digital media facilitate other communication forms than text, so-called ‘multimodal’ communication, which should not be confused with the term ‘multimedia’. While multimedia...... for developing pedagogies where a synergy of different symbol systems facilitates new and flexible learning situations that can meet different needs of different learners. The present paper includes an example from a Danish university program....

  8. Influence of a variable Rayleigh scattering-loss coefficient on the light backscattering in multimode optical fibers.

    Science.gov (United States)

    Bisyarin, M A; Kotov, O I; Hartog, A H; Liokumovich, L B; Ushakov, N A

    2017-06-01

    The recently developed diffraction technique of analytical investigation of the Rayleigh backscattering produced by an incident fundamental mode in a multimode optical fiber with an arbitrary refractive index profile is supplemented by taking into account the Rayleigh scattering-loss coefficient, which could be variable within the fiber cross section. The relative changes in various radial and azimuthal modes' excitation levels, due to some typical radial dependences of this coefficient, are computed for the quadratic- and step-index fibers. It is stated that the excitation efficiency could either rise or decay for different modes. The effect of the variable Rayleigh scattering-loss coefficient is shown to be more noticeable in the fibers with a quadratic refractive index profile, whereas it is negligible in actual multimode step-index fibers.

  9. Combined single-mode/multimode fiber link supporting simplified in-building 60-GHz gigabit wireless access

    DEFF Research Database (Denmark)

    Pham, Tien Thang; Lebedev, Alexander; Beltrán, Marta

    2012-01-01

    In this paper, we propose and experimentally demonstrate a simple, cost-effective hybrid gigabit fiber-wireless system for in-building wireless access. Simplicity and cost-effectiveness are achieved in all parts of the system by utilizing direct laser modulation, optical frequency up-conversion, ......In this paper, we propose and experimentally demonstrate a simple, cost-effective hybrid gigabit fiber-wireless system for in-building wireless access. Simplicity and cost-effectiveness are achieved in all parts of the system by utilizing direct laser modulation, optical frequency up......-conversion, combined single mode/multimode fiber transmission and envelope detection. Error-free transmission of 2-Gbps data in 60-GHz band over a composite channel including 10-km standard single-mode fiber (SSMF)/1-km multimode fiber (MMF) and 6.5-m air transmission was successfully achieved....

  10. Drastic sensitivity enhancement of temperature sensing based on multimodal interference in polymer optical fibers

    Science.gov (United States)

    Numata, Goki; Hayashi, Neisei; Tabaru, Marie; Mizuno, Yosuke; Nakamura, Kentaro

    2015-07-01

    It has been reported that temperature sensors based on modal interference in perfluorinated graded-index polymer optical fibers show extremely high temperature sensitivity at room temperature. In this work, we confirm that the temperature sensitivity (absolute value) is significantly enhanced when the temperature increases toward ∼70 °C, which is close to the glass-transition temperature of the core polymer. When the core diameter is 62.5 µm, the sensitivity at 72 °C at 1300 nm is 202 nm/°C/m, which is approximately 26 times the value obtained at room temperature and >7000 times the highest value previously reported using a silica multimode fiber.

  11. Multimode fiber modal decomposition based on hybrid genetic global optimization algorithm

    Science.gov (United States)

    Li, Lei; Leng, Jinyong; Zhou, Pu; Chen, Jinbao

    2017-10-01

    Numerical modal decomposition (MD) is an effective approach to reveal modal characteristics in high power fiber lasers. The main challenge is to find a suitable multi-dimensional optimization algorithm to reveal exact superposition of eigenmodes, especially for multimode fiber. A novel hybrid genetic global optimization algorithm, named GA-SPGD, which combines the advantages of genetic algorithm (GA) and stochastic parallel gradient descent (SPGD) algorithm, is firstly proposed to reduce local minima possibilities from sensitivity initial values. Firstly, GA is applied to search the rough global optimization position based on near-far-field intensity distribution with high accuracy. Upon those initial values, SPGD algorithm is afterwards used to find the exact optimization values based on near-field intensity distribution with fast convergence speed. Numerical simulations validate the feasibility and reliability.

  12. Tissue imaging using full field optical coherence microscopy with short multimode fiber probe

    Science.gov (United States)

    Sato, Manabu; Eto, Kai; Goto, Tetsuhiro; Kurotani, Reiko; Abe, Hiroyuki; Nishidate, Izumi

    2018-03-01

    In achieving minimally invasive accessibility to deeply located regions the size of the imaging probes is important. We demonstrated full-field optical coherence tomography (FF-OCM) using an ultrathin forward-imaging short multimode fiber (SMMF) probe of 50 μm core diameter, 125 μm diameter, and 7.4 mm length for optical communications. The axial resolution was measured to be 2.14 μm and the lateral resolution was also evaluated to be below 4.38 μm using a test pattern (TP). The spatial mode and polarization characteristics of SMMF were evaluated. Inserting SMMF to in vivo rat brain, 3D images were measured and 2D information of nerve fibers was obtained. The feasibility of an SMMF as an ultrathin forward-imaging probe in FF-OCM has been demonstrated.

  13. High-resolution wavefront shaping with a photonic crystal fiber for multimode fiber imaging

    NARCIS (Netherlands)

    Amitonova, L. V.; Descloux, A.; Petschulat, J.; Frosz, M. H.; Ahmed, G.; Babic, F.; Jiang, X.; Mosk, A. P.|info:eu-repo/dai/nl/186344686; Russell, P. S. J.; Pinkse, P.W.H.

    2016-01-01

    We demonstrate that a high-numerical-aperture photonic crystal fiber allows lensless focusing at an unparalleled res- olution by complex wavefront shaping. This paves the way toward high-resolution imaging exceeding the capabilities of imaging with multi-core single-mode optical fibers. We analyze

  14. High-resolution wavefront shaping with a photonic crystal fiber for multimode fiber imaging

    NARCIS (Netherlands)

    Amitonova, Lyubov; Descloux, Adrien; Petschulat, Joerg; Frosz, Michael H.; Ahmed, Goran; Babic, Fehim; Mosk, Allard; Russell, Philip St.J.; Pinkse, Pepijn Willemszoon Harry

    2016-01-01

    We demonstrate that a high-numerical-aperture photonic crystal fiber allows lensless focusing at an unparalleled resolution by complex wavefront shaping. This paves the way toward high-resolution imaging exceeding the capabilities of imaging with multi-core single-mode optical fibers. We analyze the

  15. Theoretical modeling of a coupled plasmon waveguide resonance sensor based on multimode optical fiber

    Science.gov (United States)

    Liu, Kun; Xue, Meng; Jiang, Junfeng; Wang, Tao; Chang, Pengxiang; Liu, Tiegen

    2018-03-01

    A coupled plasmon waveguide resonance (CPWR) sensor based on metal/dielectric-coated step index multimode optical fiber is proposed. Theoretical simulations using the four-layer Fresnel equations based on a bi-dimensional optical fiber model were implemented on four structures: Ag-ZnO, Au-ZnO, Ag-TiO2 and Au-TiO2. By controlling the thickness of dielectric layer, we managed to manipulate the CPWR resonance wavelengths. When a CPWR resonance dip is in the short wavelength region, it is insensitive to the change of surrounding refractive index (SRI) and can be used as a reference to improve the sensing accuracy of surface plasmon resonance (SPR) mode. With the increase of the thickness of the dielectric layer, the CPWR resonance dips shift to longer wavelength and the corresponding sensitivities increase. When the 1st CPWR resonance wavelength is near 1550 nm and SRI is around 1.333, the sensitivities of four structures reach 1360.61 nm/RIU, 1375.76 nm/RIU, 1048.48 nm/RIU and 1015.15 nm/RIU, respectively. The values are close to that of the conventional SPR optical fiber sensor while the spectral bandwidths of the optical fiber CPWR sensors are narrower.

  16. Label free imaging system for measuring blood flow speeds using a single multi-mode optical fiber (Conference Presentation)

    Science.gov (United States)

    Sigal, Iliya; Caravaca Aguirre, Antonio M.; Gad, Raanan; Piestun, Rafael; Levi, Ofer

    2016-03-01

    We demonstrate a single multi-mode fiber-based micro-endoscope for measuring blood flow speeds. We use the transmission-matrix wavefront shaping approach to calibrate the multi-mode fiber and raster-scan a focal spot across the distal fiber facet, imaging the cross-polarized back-reflected light at the proximal facet using a camera. This setup allows assessment of the backscattered photon statistics: by computing the mean speckle contrast values across the proximal fiber facet we show that spatially-resolved flow speed maps can be inferred by selecting an appropriate camera integration time. The proposed system is promising for minimally-invasive studies of neurovascular coupling in deep brain structures.

  17. Lipid-protein interactions in plasma membranes of fiber cells isolated from the human eye lens.

    Science.gov (United States)

    Raguz, Marija; Mainali, Laxman; O'Brien, William J; Subczynski, Witold K

    2014-03-01

    The protein content in human lens membranes is extremely high, increases with age, and is higher in the nucleus as compared with the cortex, which should strongly affect the organization and properties of the lipid bilayer portion of intact membranes. To assess these effects, the intact cortical and nuclear fiber cell plasma membranes isolated from human lenses from 41- to 60-year-old donors were studied using electron paramagnetic resonance spin-labeling methods. Results were compared with those obtained for lens lipid membranes prepared from total lipid extracts from human eyes of the same age group [Mainali, L., Raguz, M., O'Brien, W. J., and Subczynski, W. K. (2013) Biochim. Biophys. Acta]. Differences were considered to be mainly due to the effect of membrane proteins. The lipid-bilayer portions of intact membranes were significantly less fluid than lipid bilayers of lens lipid membranes, prepared without proteins. The intact membranes were found to contain three distinct lipid environments termed the bulk lipid domain, boundary lipid domain, and trapped lipid domain. However, the cholesterol bilayer domain, which was detected in cortical and nuclear lens lipid membranes, was not detected in intact membranes. The relative amounts of bulk and trapped lipids were evaluated. The amount of lipids in domains uniquely formed due to the presence of membrane proteins was greater in nuclear membranes than in cortical membranes. Thus, it is evident that the rigidity of nuclear membranes is greater than that of cortical membranes. Also the permeability coefficients for oxygen measured in domains of nuclear membranes were significantly lower than appropriate coefficients measured in cortical membranes. Relationships between the organization of lipids into lipid domains in fiber cells plasma membranes and the organization of membrane proteins are discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Impulse radio ultra wide-band over multi-mode fiber for in-home signal distribution

    DEFF Research Database (Denmark)

    Caballero Jambrina, Antonio; Rodes, Roberto; Jensen, Jesper Bevensee

    2009-01-01

    We propose and experimentally demonstrate a high speed impulse radio ultra wide-band (IR-UWB) wireless link for in-home network signal distribution. The IR-UWB pulse is distributed over a multimode fiber to the transmitter antenna. Wireless transmitted bit-rates of 1 Gbps at 2 m and 2 Gbps at 1.5 m...

  19. Evaluation of a multimode fiber optic low coherence interferometer for path length resolved Doppler measurments of diffuse light

    NARCIS (Netherlands)

    Varghese, Babu; Rajan, Vinayakrishnan; van Leeuwen, Ton; Steenbergen, Wiendelt

    2007-01-01

    The performance of a graded index multimode fiber optic low coherence Mach-Zehnder interferometer with phase modulation is analyzed. Investigated aspects were its ability to measure path length distributions and to perform path length resolved Doppler measurements of multiple scattered photons in a

  20. Evaluation of a multimode fiber optic low coherence interferometer for path length resolved Doppler measurements of diffuse light

    NARCIS (Netherlands)

    Varghese, Babu; Rajan, Vinayakrishnan; van Leeuwen, Ton G.; Steenbergen, Wiendelt

    2007-01-01

    The performance of a graded index multimode fiber optic low coherence Mach-Zehnder interferometer with phase modulation is analyzed. Investigated aspects were its ability to measure path length distributions and to perform path length resolved Doppler measurements of multiple scattered photons in a

  1. Ball lens coupled fiber-optic probe for depth-resolved spectroscopy of epithelial tissue.

    Science.gov (United States)

    Schwarz, Richard A; Arifler, Dizem; Chang, Sung K; Pavlova, Ina; Hussain, Insiya A; Mack, Vivian; Knight, Bob; Richards-Kortum, Rebecca; Gillenwater, Ann M

    2005-05-15

    A ball lens coupled fiber-optic probe design is described for depth-resolved measurements of the fluorescence and reflectance properties of epithelial tissue. A reflectance target, fluorescence targets, and a two-layer tissue phantom consisting of fluorescent microspheres suspended in collagen are used to characterize the performance of the probe. Localization of the signal to within 300 microm of the probe tip is observed by use of reflectance and fluorescence targets in air. Differential enhancement of the fluorescence signal from the top layer of the two-layer tissue phantom is observed.

  2. Single lens photometric machine vision with 3D imaging for fiber-to-chip coupling.

    Science.gov (United States)

    Liu, Xu; Hu, Hongmei; Sun, Xiaohan

    2012-03-01

    A single lens photometric machine vision (SLPMV) optical microbench is presented and built for fiber-to-chip coupling. By a rotation mechanics in SLPMV, the multi-view-camera can scan the various surface status of the chips coupled. To realize 3D imaging more explicitly, the modified photometric stereo algorithm is proposed through acquiring the images of weak saturation, matching the scanning illuminative angles, and rectifying rectangularly the original images. The reconstructed images have had similar qualities as those obtained by scanning electron microscopy and have unveiled the detailed information obscured in the 2D images. For the InP-based optical waveguide chip coupled with wedge-shaped fiber, the insertion loss tested on the SLPMV is 3 dB less than one on the conventional testing station. The SLPMV could serve as a more cost-effective and compact scientific observation instrumentation in imaging informatics than commercial ones.

  3. Multimodal nonlinear microscope based on a compact fiber-format laser source

    Science.gov (United States)

    Crisafi, Francesco; Kumar, Vikas; Perri, Antonio; Marangoni, Marco; Cerullo, Giulio; Polli, Dario

    2018-01-01

    We present a multimodal non-linear optical (NLO) laser-scanning microscope, based on a compact fiber-format excitation laser and integrating coherent anti-Stokes Raman scattering (CARS), stimulated Raman scattering (SRS) and two-photon-excitation fluorescence (TPEF) on a single platform. We demonstrate its capabilities in simultaneously acquiring CARS and SRS images of a blend of 6-μm poly(methyl methacrylate) beads and 3-μm polystyrene beads. We then apply it to visualize cell walls and chloroplast of an unprocessed fresh leaf of Elodea aquatic plant via SRS and TPEF modalities, respectively. The presented NLO microscope, developed in house using off-the-shelf components, offers full accessibility to the optical path and ensures its easy re-configurability and flexibility.

  4. Fiber-optic Raman probe couples ball lens for depth-selected Raman measurements of epithelial tissue

    OpenAIRE

    Mo, Jianhua; Zheng, Wei; Huang, Zhiwei

    2010-01-01

    In this study, we present a fiber-optic ball lens Raman probe design for improving depth-selected Raman measurements of epithelial tissue. The Monte Carlo simulation results show that tissue Raman collection efficiency can be improved by properly selecting the refractive index and the diameter of the ball lens for the Raman probe design and the depth-selectivity of Raman measurements can also be improved by either increasing the refractive index or reducing the diameter of the ball lens. An a...

  5. Apparatus for Direct Optical Fiber Through-Lens Illumination of Microscopy or Observational Objects

    Science.gov (United States)

    Kadogawa, Hiroshi (Inventor)

    2001-01-01

    In one embodiment of the invention, a microscope or other observational apparatus, comprises a hollow tube, a lens mounted to the tube, a light source and at least one flexible optical fiber having an input end and an output end. The input end is positioned to receive light from the light source, and the output end is positioned within the tube so as to directly project light along a straight path to the lens to illuminate an object to be viewed. The path of projected light is uninterrupted and free of light deflecting elements. By passing the light through the lens, the light can be diffused or otherwise defocused to provide more uniform illumination across the surface of the object, increasing the quality of the image of the object seen by the viewer. The direct undeflected and uninterrupted projection of light, without change of direction, eliminates the need for light-deflecting elements, such as beam-splitters, mirrors, prisms, or the like, to direct the projected light towards the object.

  6. Simultaneous transmission of the IEEE 802.11 radio signal and optical Gbit Ethernet over the multimode fiber link

    Science.gov (United States)

    Maksymiuk, L.; Podziewski, A.

    2015-09-01

    In the paper we present a successful joint transmission of the IEEE 802.11 signal and an optical Gbit Ethernet over a multimode fiber based link. Most importantly, the multiplexation of both signals was performed in the optical domain. Due to the utilization of the multimode fiber the OBI noise was avoided and both channels were able to operate at the same wavelength. We prove that potential RoF link for IEEE 802.11 signal distribution may be used to additionally transmit other signals as Gbit Ethernet and therefore utilize the fiber infrastructure installed more effectively. The qualities of both the IEEE 802.11 and Ethernet transmissions fulfilled the requirements imposed by appropriate standards.

  7. Choosing a Better Delay Line Medium between Single-Mode and Multi-Mode Optical Fibers: the Effect of Bending

    Directory of Open Access Journals (Sweden)

    Auwal Mustapha Imam

    2017-12-01

    Full Text Available Optical fiber cables are materials whose core is made of silica and other materials such as chalcogenide glasses; they transmit a digital signal via light pulses through an extremely thin strand of glass. The light propagates and is being guided by the core which is surrounded by the cladding. Light travels in the optical fiber in the form of total internal reflection in the core of the fibers. The flexibility, low tensile strength, low signal loss, high bandwidth and other characteristics of optical fibers favors it for use as a delay medium in many applications. Another favorable characteristic of optical fiber delay lines is are their relative insensitivities to environmental effects and electromagnetic interferences. The immunity of optical fibers to interferences and their less weight added advantages to it for use as delay medium. Single-mode and multi-mode are the two most popular types of optical fibers. Single-mode fibers have good propagation and delay properties with a minimal loss that allows the signal to propagate in a large distance with insignificant distortion or attenuation. The percentage of power transmission of single-mode fibers is found to be higher than that of the multi-mode fibers. It is, therefore, a preferred type for use as a delay line. In this paper, relative studies of the two optical fibers modes, and the results of power input/output measurement of the two modes are presented with a view to coming up with a better type for use as a delay medium.

  8. Fiber-optic Raman probe couples ball lens for depth-selected Raman measurements of epithelial tissue.

    Science.gov (United States)

    Mo, Jianhua; Zheng, Wei; Huang, Zhiwei

    2010-06-28

    In this study, we present a fiber-optic ball lens Raman probe design for improving depth-selected Raman measurements of epithelial tissue. The Monte Carlo simulation results show that tissue Raman collection efficiency can be improved by properly selecting the refractive index and the diameter of the ball lens for the Raman probe design and the depth-selectivity of Raman measurements can also be improved by either increasing the refractive index or reducing the diameter of the ball lens. An appropriate arrangement of the Raman probe-tissue distance can also optimize the collection efficiency for depth-resolved Raman measurements. Experimental evaluation of a ball lens Raman probe design on a two-layer tissue phantom confirms the potential of the ball lens Raman probe design for efficient depth-selected measurement on epithelial tissue. This work suggests that the fiber-optic Raman probe coupled with a ball lens can facilitate the depth-selected Raman measurements of epithelial tissue, which may improve the diagnosis of epithelial precancer and early cancer at the molecular level.

  9. Stimulated Brillouin scattering in highly birefringent multimode tapered chalcogenide photonic crystal fiber for distributed optical sensors (Retraction Notice)

    Science.gov (United States)

    Baili, Amira; Cherif, Rim; Zghal, Mourad

    2016-09-01

    This paper, originally published on September 15, 2016, was retracted from the SPIE Digital Library on October 5, 2016, due to a high degree of similarity between specific portions of the text of the paper to the following publications: J. Tchahame, J. Beugnot, A. Kudlinski, and T. Sylvestre, "Multimode Brillouin spectrum in a long tapered birefringent photonic crystal fiber," Opt. Lett. 40, 4281-4284 (2015). doi: 10.1364/OL.40.004281 W. W. Ke, X. J. Wang and X. Tang, "Stimulated Brillouin Scattering Model in Multi-Mode Fiber Lasers," in IEEE Journal of Selected Topics in Quantum Electronics, vol. 20, no. 5, pp. 305-314, Sept.-Oct. 2014. doi: 10.1109/JSTQE.2014.2303256.

  10. Dual CARS and SHG image acquisition scheme that combines single central fiber and multimode fiber bundle to collect and differentiate backward and forward generated photons

    Science.gov (United States)

    Weng, Sheng; Chen, Xu; Xu, Xiaoyun; Wong, Kelvin K.; Wong, Stephen T. C.

    2016-01-01

    In coherent anti-Stokes Raman scattering (CARS) and second harmonic generation (SHG) imaging, backward and forward generated photons exhibit different image patterns and thus capture salient intrinsic information of tissues from different perspectives. However, they are often mixed in collection using traditional image acquisition methods and thus are hard to interpret. We developed a multimodal scheme using a single central fiber and multimode fiber bundle to simultaneously collect and differentiate images formed by these two types of photons and evaluated the scheme in an endomicroscopy prototype. The ratio of these photons collected was calculated for the characterization of tissue regions with strong or weak epi-photon generation while different image patterns of these photons at different tissue depths were revealed. This scheme provides a new approach to extract and integrate information captured by backward and forward generated photons in dual CARS/SHG imaging synergistically for biomedical applications. PMID:27375938

  11. Multi-mode optical fibers for connecting space-based spectrometers

    Science.gov (United States)

    Roberts, W. T.; Lindenmisth, C. A.; Bender, S.; Miller, E. A.; Motts, E.; Ott, M.; LaRocca, F.; Thomes, J.

    2017-11-01

    significantly smaller, less massive and less robust. Large core multi-mode optical fibers are often used to accommodate the optical connection of the two separated portions of such instrumentation. In some cases, significant throughput efficiency improvement can be realized by judiciously orienting the strands of multi-fiber cable, close-bunching them to accommodate a tight focus of the optical system on the optical side of the connection, and splaying them out linearly along a spectrometer slit on the other end. For such instrumentation to work effectively in identifying elements and molecules, and especially to produce accurate quantitative results, the spectral throughput of the optical fiber connection must be consistent over varying temperatures, over the range of motion of the optical head (and it's implied optical cable stresses), and over angle-aperture invariant of the total system. While the first two of these conditions have been demonstrated[4], spectral observations of the latter present a cause for concern, and may have an impact on future design of fiber-connected LIBS and Raman spectroscopy instruments. In short, we have observed that the shape of the spectral efficiency curve of a large multi-mode core optical fiber changes as a function of input angle.

  12. Effects of laser frequency chirp on modal noise in short-range radio over multimode fiber links

    DEFF Research Database (Denmark)

    Visani, Davide; Tartarini, Giovanni; Petersen, Martin Nordal

    2010-01-01

    An important effect of the frequency chirp of the optical transmitter in radio over multimode fiber links is put into evidence experimentally and modeled theoretically for the first time, to our knowledge. This effect can have an important impact in short-range connections, where, although...... intermodal dispersion does not generally cause unacceptable limitations to the transmittable bandwidth, the presence of modal noise must be accurately kept under control, since it determines undesired real-time fluctuations of the link....

  13. Transmission of 112 Gb/s PM-QPSK signals over up to 635 km of multimode optical fiber.

    Science.gov (United States)

    Downie, John D; Hurley, Jason E; Kuksenkov, Dmitri V; Lynn, Christopher M; Korolev, Andrey E; Nazarov, Vladimir N

    2011-12-12

    We investigate transmission of 112 Gb/s PM-QPSK signals over 50 μm core diameter OM3 multimode fiber using the center launch approach. We demonstrate successful transmission of 16 DWDM channels over a distance of 635 km for a capacity-distance product of 1016 Tb/s-km. The limiting impairment appears due to mode coupling and multipath interference effects. © 2011 Optical Society of America

  14. Mode power distribution effect in white-light multimode fiber extrinsic Fabry-Perot interferometric sensor systems.

    Science.gov (United States)

    Han, Ming; Wang, Anbo

    2006-05-01

    Theoretical and experimental results have shown that mode power distribution (MPD) variations could significantly vary the phase of spectral fringes from multimode fiber extrinsic Fabry-Perot interferometric (MMF-EFPI) sensor systems, owing to the fact that different modes introduce different extra phase shifts resulting from the coupling of modes reflected at the second surface to the lead-in fiber end. This dependence of fringe pattern on MPD could cause measurement errors in signal demodulation methods of white-light MMF-EFPI sensors that implement the phase information of the fringes.

  15. Beveled fiber-optic probe couples a ball lens for improving depth-resolved fluorescence measurements of layered tissue: Monte Carlo simulations

    International Nuclear Information System (INIS)

    Jaillon, Franck; Zheng Wei; Huang Zhiwei

    2008-01-01

    In this study, we evaluate the feasibility of designing a beveled fiber-optic probe coupled with a ball lens for improving depth-resolved fluorescence measurements of epithelial tissue using Monte Carlo (MC) simulations. The results show that by using the probe configuration with a beveled tip collection fiber and a flat tip excitation fiber associated with a ball lens, discrimination of fluorescence signals generated in different tissue depths is achievable. In comparison with a flat-tip collection fiber, the use of a large bevel angled collection fiber enables a better differentiation between the shallow and deep tissue layers by changing the excitation-collection fiber separations. This work suggests that the beveled fiber-optic probe coupled with a ball lens has the potential to facilitate depth-resolved fluorescence measurements of epithelial tissues

  16. Beveled fiber-optic probe couples a ball lens for improving depth-resolved fluorescence measurements of layered tissue: Monte Carlo simulations.

    Science.gov (United States)

    Jaillon, Franck; Zheng, Wei; Huang, Zhiwei

    2008-02-21

    In this study, we evaluate the feasibility of designing a beveled fiber-optic probe coupled with a ball lens for improving depth-resolved fluorescence measurements of epithelial tissue using Monte Carlo (MC) simulations. The results show that by using the probe configuration with a beveled tip collection fiber and a flat tip excitation fiber associated with a ball lens, discrimination of fluorescence signals generated in different tissue depths is achievable. In comparison with a flat-tip collection fiber, the use of a large bevel angled collection fiber enables a better differentiation between the shallow and deep tissue layers by changing the excitation-collection fiber separations. This work suggests that the beveled fiber-optic probe coupled with a ball lens has the potential to facilitate depth-resolved fluorescence measurements of epithelial tissues.

  17. Evaluation of optical ZP-OFDM transmission performance in multimode fiber links.

    Science.gov (United States)

    Medina, Pau; Almenar, Vicenç; Corral, Juan L

    2014-01-13

    In this paper, the performance of Zero Padding Orthogonal Frequency Division Multiplexing (ZP-OFDM) on intensity modulation-direct detection (IM-DD) multimode fiber (MMF) links is assessed by means of numerical simulations. The performance of ZP-OFDM is compared to classical Cyclic Prefixed form of OFDM (CP-OFDM) which is known to offer a limited performance in terms of symbol recovery in subcarriers suffering severe fading. Simulations results show that ZP-OFDM is able to reach 29 Gbps in 99.5% of all installed MMF links up to 600 meters compared to 14 Gbps for CP-OFDM when a 64 points fast Fourier transform (FFT) size is used. The use of ZP-OFDM makes it possible to increase the link length up to 1200 and 2400 m with a 25 Gbps data rate if the FFT sizes are increased to 128 and 256 points, respectively; whereas the CP-OFDM scheme will offer a maximum data rate of 10 Gbps in both cases. ZP-OFDM can be an alternative to adaptive loading OFDM schemes without the need of a negotiation between transmitter and receiver, reducing the system deployment complexity and increasing the flexibility in scenarios with multiple receivers.

  18. Gasohol Quality Control for Real Time Applications by Means of a Multimode Interference Fiber Sensor

    Directory of Open Access Journals (Sweden)

    Adolfo J. Rodríguez Rodríguez

    2014-09-01

    Full Text Available In this work we demonstrate efficient quality control of a variety of gasoline and ethanol (gasohol blends using a multimode interference (MMI fiber sensor. The operational principle relies on the fact that the addition of ethanol to the gasohol blend reduces the refractive index (RI of the gasoline. Since MMI sensors are capable of detecting small RI changes, the ethanol content of the gasohol blend is easily determined by tracking the MMI peak wavelength response. Gasohol blends with ethanol contents ranging from 0% to 50% has been clearly identified using this device, which provides a linear response with a maximum sensitivity of 0.270 nm/% EtOH. The sensor can also distinguish when water incorporated in the blend has exceeded the maximum volume tolerated by the gasohol blend, which is responsible for phase separation of the ethanol and gasoline and could cause serious engine failures. Since the MMI sensor is straightforward to fabricate and does not require any special coating it is a cost effective solution for real time and in-situ monitoring of the quality of gasohol blends.

  19. Sensors Based on Thin-Film Coated Cladding Removed Multimode Optical Fiber and Single-Mode Multimode Single-Mode Fiber: A Comparative Study

    Directory of Open Access Journals (Sweden)

    Ignacio Del Villar

    2015-01-01

    Full Text Available Two simple optical fibre structures that do not require the inscription of a grating, a cladding removed multimode optical fibre (CRMOF and a single-mode multimode single-mode structure (SMS, are compared in terms of their adequateness for sensing once they are coated with thin-films. The thin-film deposited (TiO2/PSS permits increasing the sensitivity to surrounding medium refractive index. The results obtained can be extrapolated to other fields such as biological or chemical sensing just by replacing the thin-film by a specific material.

  20. Properties of Fiber Cell Plasma Membranes Isolated from the Cortex and Nucleus of the Porcine Eye Lens

    Science.gov (United States)

    Mainali, Laxman; Raguz, Marija; O’Brien, William J.; Subczynski, Witold K.

    2012-01-01

    The organization and physical properties of the lipid bilayer portion of intact cortical and nuclear fiber cell plasma membranes isolated from the eyes lenses of two-year-old pigs were studied using electron paramagnetic resonance (EPR) spin-labeling. Membrane fluidity, hydrophobicity, and the oxygen transport parameter (OTP) were assessed from the EPR spectra of precisely positioned spin labels. Intact cortical and nuclear membranes, which include membrane proteins, were found to contain three distinct lipid environments. These lipid environments were termed the bulk lipid domain, boundary lipid domain, and trapped lipid domain (lipids in protein aggregates). The amount of boundary and trapped lipids was greater in intact nuclear membranes than in cortical membranes. The properties of intact membranes were compared with the organization and properties of lens lipid membranes made of the total lipid extracts from the lens cortex or nucleus. In cortical lens lipid membranes, only one homogenous environment was detected, which was designated as a bulk lipid domain (phospholipid bilayer saturated with cholesterol). Lens lipid membranes prepared from the lens nucleus possessed two domains, assigned as a bulk lipid domain and a cholesterol bilayer domain (CBD). In intact nuclear membranes, it was difficult to discriminate the CBD, which was clearly detected in nuclear lens lipid membranes because the OTP measured in the CBD is the same as in the domain formed by trapped lipids. The two domains unique to intact membranes—namely, the domain formed by boundary lipids and the domain formed by trapped lipids—were most likely formed due to the presence of membrane proteins. It is concluded that formation of rigid and practically impermeable domains is enhanced in the lens nucleus, indicating changes in membrane composition that may help to maintain low oxygen concentration in this lens region. PMID:22326289

  1. Experimental study on the statistic characteristics of a 3x3 RF MIMO channel over a single conventional multimode fiber.

    Science.gov (United States)

    Lei, Yi; Li, Jianqiang; Wu, Rui; Fan, Yuting; Fu, Songnian; Yin, Feifei; Dai, Yitang; Xu, Kun

    2017-06-01

    Based on the observed random fluctuation phenomenon of speckle pattern across multimode fiber (MMF) facet and received optical power distribution across three output ports, we experimentally investigate the statistic characteristics of a 3×3 radio frequency multiple-input multiple-output (MIMO) channel enabled by mode division multiplexing in a conventional 50 µm MMF using non-mode-selective three-dimensional waveguide photonic lanterns as mode multiplexer and demultiplexer. The impacts of mode coupling on the MIMO channel coefficients, channel matrix, and channel capacity have been analyzed over different fiber lengths. The results indicate that spatial multiplexing benefits from the greater fiber length with stronger mode coupling, despite a higher optical loss.

  2. Quasi-homogeneous partial coherent source modeling of multimode optical fiber output using the elementary source method

    Science.gov (United States)

    Fathy, Alaa; Sabry, Yasser M.; Khalil, Diaa A.

    2017-10-01

    Multimode fibers (MMF) have many applications in illumination, spectroscopy, sensing and even in optical communication systems. In this work, we present a model for the MMF output field assuming the fiber end as a quasi-homogenous source. The fiber end is modeled by a group of partially coherent elementary sources, spatially shifted and uncorrelated with each other. The elementary source distribution is derived from the far field intensity measurement, while the weighting function of the sources is derived from the fiber end intensity measurement. The model is compared with practical measurements for fibers with different core/cladding diameters at different propagation distances and for different input excitations: laser, white light and LED. The obtained results show normalized root mean square error less than 8% in the intensity profile in most cases, even when the fiber end surface is not perfectly cleaved. Also, the comparison with the Gaussian-Schell model results shows a better agreement with the measurement. In addition, the complex degree of coherence, derived from the model results, is compared with the theoretical predictions of the modified Van Zernike equation showing very good agreement, which strongly supports the assumption that the large core MMF could be considered as a quasi-homogenous source.

  3. Temperature sensing based on multimodal interference in polymer optical fibers: Room-temperature sensitivity enhancement by annealing

    Science.gov (United States)

    Kawa, Tomohito; Numata, Goki; Lee, Heeyoung; Hayashi, Neisei; Mizuno, Yosuke; Nakamura, Kentaro

    2017-07-01

    To date, we have developed a temperature sensor based on multimodal interference in a polymer optical fiber (POF) with an extremely high sensitivity. Here, we experimentally evaluate the influence of annealing (heat treatment) of the POF on the temperature sensitivity at room temperature. We show that the temperature sensitivity is enhanced with increasing annealing temperature, and that, by annealing the POF at 90 °C, we can achieve a temperature sensitivity of +2.17 nm/°C, which is 2.9 times larger than that without annealing (+0.75 nm/°C).

  4. Ankyrin-B directs membrane tethering of periaxin and is required for maintenance of lens fiber cell hexagonal shape and mechanics.

    Science.gov (United States)

    Maddala, Rupalatha; Walters, Mark; Brophy, Peter J; Bennett, Vann; Rao, Ponugoti V

    2016-01-15

    Periaxin (Prx), a PDZ domain protein expressed preferentially in myelinating Schwann cells and lens fibers, plays a key role in membrane scaffolding and cytoarchitecture. Little is known, however, about how Prx is anchored to the plasma membrane. Here we report that ankyrin-B (AnkB), a well-characterized adaptor protein involved in linking the spectrin-actin cytoskeleton to integral membrane proteins, is required for membrane association of Prx in lens fibers and colocalizes with Prx in hexagonal fiber cells. Under AnkB haploinsufficiency, Prx accumulates in the soluble fraction with a concomitant loss from the membrane-enriched fraction of mouse lenses. Moreover, AnkB haploinsufficiency induced age-dependent disruptions in fiber cell hexagonal geometry and radial alignment and decreased compressive stiffness in mouse lenses parallel to the changes observed in Prx null mouse lens. Both AnkB- and Prx-deficient mice exhibit disruptions in membrane organization of the spectrin-actin network and the dystrophin-glycoprotein complex in lens fiber cells. Taken together, these observations reveal that AnkB is required for Prx membrane anchoring and for maintenance of lens fiber cell hexagonal geometry, membrane skeleton organization, and biomechanics. Copyright © 2016 the American Physiological Society.

  5. An optimized routing algorithm for the automated assembly of standard multimode ribbon fibers in a full-mesh optical backplane

    Science.gov (United States)

    Basile, Vito; Guadagno, Gianluca; Ferrario, Maddalena; Fassi, Irene

    2018-03-01

    In this paper a parametric, modular and scalable algorithm allowing a fully automated assembly of a backplane fiber-optic interconnection circuit is presented. This approach guarantees the optimization of the optical fiber routing inside the backplane with respect to specific criteria (i.e. bending power losses), addressing both transmission performance and overall costs issues. Graph theory has been exploited to simplify the complexity of the NxN full-mesh backplane interconnection topology, firstly, into N independent sub-circuits and then, recursively, into a limited number of loops easier to be generated. Afterwards, the proposed algorithm selects a set of geometrical and architectural parameters whose optimization allows to identify the optimal fiber optic routing for each sub-circuit of the backplane. The topological and numerical information provided by the algorithm are then exploited to control a robot which performs the automated assembly of the backplane sub-circuits. The proposed routing algorithm can be extended to any array architecture and number of connections thanks to its modularity and scalability. Finally, the algorithm has been exploited for the automated assembly of an 8x8 optical backplane realized with standard multimode (MM) 12-fiber ribbons.

  6. Variations in retinal nerve fiber layer measurements on optical coherence tomography after implantation of trifocal intraocular lens.

    Science.gov (United States)

    García-Bella, Javier; Martínez de la Casa, José M; Talavero González, Paula; Fernández-Vigo, José I; Valcarce Rial, Laura; García-Feijóo, Julián

    2018-01-01

    To establish the changes produced after implantation of a trifocal intraocular lens (IOL) on retinal nerve fiber layer measurements performed with Fourier-domain optical coherence tomography (OCT). This prospective study included 100 eyes of 50 patients with bilateral cataract in surgical range, no other associated ocular involvement, refractive errors between +5 and -5 spherical diopters, and less than 1.5 D of corneal astigmatism. The eyes were operated by phacoemulsification with implantation of 2 different trifocal IOLs (FineVision and AT LISA tri 839MP) in randomized equal groups. Cirrus OCT and Spectralis OCT were performed before surgery and 3 months later. Both analyzed the thickness of the nerve fiber layer and thickness divided by quadrants (6 in case of Spectralis and 4 in case of Cirrus HD). The mean age of patients was 67.5 ± 5.8 years. The global nerve fiber layer thickness measured with Spectralis OCT was 96.77 μm before surgery and 99.55 μm after. With Cirrus OCT, the global thickness was 85.29 μm before surgery and 89.77 μm after. Statistically significant differences in global thickness measurements between preimplantation and postimplantation of the IOL were found with both OCT in the 2 groups. Statistically significant differences were also found in temporal and superior quadrants. The implantation of a diffractive trifocal IOL alters the results of the optic nerve fiber layer on Fourier-domain OCT in these patients, which should be taken into account in the posterior study of these patients.

  7. Passively Q-switched dual-wavelength thulium-doped fiber laser based on a multimode interference filter and a semiconductor saturable absorber

    Science.gov (United States)

    Wang, M.; Huang, Y. J.; Ruan, S. C.

    2018-04-01

    In this paper, we have demonstrated a theta cavity passively Q-switched dual-wavelength fiber laser based on a multimode interference filter and a semiconductor saturable absorber. Relying on the properties of the fiber theta cavity, the laser can operate unidirectionally without an optical isolator. A semiconductor saturable absorber played the role of passive Q-switch while a section of single-mode-multimode-single-mode fiber structure served as an multimode interference filter and was used for selecting the lasing wavelengths. By suitably manipulating the polarization controller, stable dual-wavelength Q-switched operation was obtained at ~1946.8 nm and ~1983.8 nm with maximum output power and minimum pulse duration of ~47 mW and ~762.5 ns, respectively. The pulse repetition rate can be tuned from ~20.2 kHz to ~79.7 kHz by increasing the pump power from ~2.12 W to ~5.4 W.

  8. Advantage of multi-mode sapphire optical fiber for evanescent-field SERS sensing

    Czech Academy of Sciences Publication Activity Database

    Chen, H.; Tian, F.; Chi, J.; Kaňka, Jiří; Du, H.

    2014-01-01

    Roč. 39, č. 20 (2014), 5822-5825 ISSN 0146-9592 R&D Projects: GA MŠk(CZ) LH11038 Institutional support: RVO:67985882 Keywords : Fiber optics sensors * Backscattering * Nanomaterials Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 3.292, year: 2014

  9. Advantage of multi-mode sapphire optical fiber for evanescent-field SERS sensing

    Czech Academy of Sciences Publication Activity Database

    Chen, H.; Tian, F.; Chi, J.; Kaňka, Jiří; Du, H.

    2014-01-01

    Roč. 39, č. 20 (2014), 5822-5825 ISSN 0146-9592 R&D Projects: GA MŠk(CZ) LH11038 Institutional support: RVO:67985882 Keywords : Fiber optic s sensors * Backscattering * Nanomaterials Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 3.292, year: 2014

  10. Age-related compaction of lens fibers affects the structure and optical properties of rabbit lenses

    Directory of Open Access Journals (Sweden)

    Al-Ghoul Walid M

    2007-12-01

    Full Text Available Abstract Background The goal of this investigation was to correlate particular age-related structural changes (compaction to the amount of scatter in rabbit lenses and to determine if significant fiber compaction occurred in the nuclear and inner cortical regions. Methods New Zealand White rabbits at 16–20 months old (adult; n = 10 and at 3.5–4 years old (aged; n = 10 were utilized for this study. Immediately after euthanising, scatter was assessed in fresh lenses by low power helium-neon laser scan analysis. Scatter data was analyzed both for whole lenses and regionally, to facilitate correlation with morphometric data. After functional analysis, lenses were fixed and processed for scanning electron microcopy (SEM; right eyes and light microscopy (LM; left eyes. Morphometric analysis of SEM images was utilized to evaluate compaction of nuclear fibers. Similarly, measurements from LM images were used to assess compaction of inner cortical fibers. Results Scatter was significantly greater in aged lenses as compared to adult lenses in all regions analyzed, however the difference in the mean was slightly more pronounced in the inner cortical region. The anterior and posterior elliptical angles at 1 mm (inner fetal nucleus were significantly decreased in aged vs. adult lenses (anterior, p = 0.040; posterior, p = 0.036. However, the average elliptical angles at 2.5 mm (outer fetal nucleus were not significantly different in adult and aged lenses since all lenses examined had comparable angles to inner fetal fibers of aged lenses, i.e. they were all compacted. In cortical fibers, measures of average cross-sectional fiber area were significantly different at diameters of both 6 and 7 mm as a function of age (p = 0.011 and p = 0.005, respectively. Accordingly, the estimated fiber volume was significantly decreased in aged as compared to adult lenses at both 6 mm diameter (p = 0.016 and 7 mm diameter (p = 0.010. Conclusion Morphometric data indicates

  11. Experimental Investigation of Multi-mode Fiber Laser Cutting of Cement Mortar

    Science.gov (United States)

    2018-01-01

    This study successfully applied multi-mode laser cutting with the variation of the laser cutting speed to cement mortar for the first time. The effects of the amount of silica sand in the cement mortar on laser cutting are tested and analyzed. The kerf width and penetration depth of the specimens after laser cutting are investigated. As the laser cutting speed increases, the penetration depth decreases for both cement paste and cement mortar, whereas the kerf width becomes saturated and increases, respectively, for cement paste and cement mortar. Cross sections of the specimens are compared with illustrations. Top-view images of the cement mortar with indicators of the physical characteristics, such as re-solidification, burning, and cracks are examined, and the possible causes of these characteristics are explained. The optical absorption rates of cement-based materials are quantified at wide ranges of wavelength to compare the absorption rates in accordance with the materials compositions. The chemical composition variation before and after laser cutting is also compared by EDX (Energy Dispersive X-Ray) analysis. In addition to these observations, material removal mechanisms for cement mortar are proposed. PMID:29439431

  12. Experimental Investigation of Multi-mode Fiber Laser Cutting of Cement Mortar.

    Science.gov (United States)

    Lee, Dongkyoung; Pyo, Sukhoon

    2018-02-10

    This study successfully applied multi-mode laser cutting with the variation of the laser cutting speed to cement mortar for the first time. The effects of the amount of silica sand in the cement mortar on laser cutting are tested and analyzed. The kerf width and penetration depth of the specimens after laser cutting are investigated. As the laser cutting speed increases, the penetration depth decreases for both cement paste and cement mortar, whereas the kerf width becomes saturated and increases, respectively, for cement paste and cement mortar. Cross sections of the specimens are compared with illustrations. Top-view images of the cement mortar with indicators of the physical characteristics, such as re-solidification, burning, and cracks are examined, and the possible causes of these characteristics are explained. The optical absorption rates of cement-based materials are quantified at wide ranges of wavelength to compare the absorption rates in accordance with the materials compositions. The chemical composition variation before and after laser cutting is also compared by EDX (Energy Dispersive X-Ray) analysis. In addition to these observations, material removal mechanisms for cement mortar are proposed.

  13. Use of analyte-modulated modal power distribution in multimode optical fibers for simultaneous single-wavelength evanescent-wave refractometry and spectrometry.

    Science.gov (United States)

    Potyrailo, R A; Ruddy, V P; Hieftje, G M

    1999-11-01

    A new method is described for the simultaneous determination of absorbance and refractive index of a sample medium. The method is based on measurement of the analyte-modulated modal power distribution (MPD) in a multimode waveguide. In turn, the MPD is quantified by the far-field spatial pattern and intensity of light, i.e., the Fraunhofer diffraction pattern (registered on a CCD camera), that emerges from a multimode optical fiber. Operationally, light that is sent down the fiber interacts with the surrounding analyte-containing medium by means of the evanescent wave at the fiber boundary. The light flux in the propagating beam and the internal reflection angles within the fiber are both affected by optical absorption connected with the analyte and by the refractive index of the analyte-containing medium. In turn, these angles are reflected in the angular divergence of the beam as it leaves the fiber. As a result, the Fraunhofer diffraction pattern of that beam yields two parameters that can, together, be used to deduce refractive index and absorbance. This MPD based detection offers important advantages over traditional evanescent-wave detection strategies which rely on recording only the total transmitted optical power or its lost fraction. First, simultaneous determination of sample refractive index and absorbance is possible at a single probe wavelength. Second, the sensitivity of refractometric and absorption measurements can be controlled simply, either by adjusting the distance between the end face of the fiber and the CCD detector or by monitoring selected modal groups at the fiber output. As a demonstration of these capabilities, several weakly absorbing solutions were examined, with refractive indices in the range from 1.3330 to 1.4553 and with absorption coefficients in the range 0-16 cm-1. The new detection strategy is likely to be important in applications in which sample coloration varies and when it is necessary to compensate for variations in the

  14. Integration of Fiber-Optic Sensor Arrays into a Multi-Modal Tactile Sensor Processing System for Robotic End-Effectors

    Science.gov (United States)

    Kampmann, Peter; Kirchner, Frank

    2014-01-01

    With the increasing complexity of robotic missions and the development towards long-term autonomous systems, the need for multi-modal sensing of the environment increases. Until now, the use of tactile sensor systems has been mostly based on sensing one modality of forces in the robotic end-effector. The use of a multi-modal tactile sensory system is motivated, which combines static and dynamic force sensor arrays together with an absolute force measurement system. This publication is focused on the development of a compact sensor interface for a fiber-optic sensor array, as optic measurement principles tend to have a bulky interface. Mechanical, electrical and software approaches are combined to realize an integrated structure that provides decentralized data pre-processing of the tactile measurements. Local behaviors are implemented using this setup to show the effectiveness of this approach. PMID:24743158

  15. Integration of fiber-optic sensor arrays into a multi-modal tactile sensor processing system for robotic end-effectors.

    Science.gov (United States)

    Kampmann, Peter; Kirchner, Frank

    2014-04-16

    With the increasing complexity of robotic missions and the development towards long-term autonomous systems, the need for multi-modal sensing of the environment increases. Until now, the use of tactile sensor systems has been mostly based on sensing one modality of forces in the robotic end-effector. The use of a multi-modal tactile sensory system is motivated, which combines static and dynamic force sensor arrays together with an absolute force measurement system. This publication is focused on the development of a compact sensor interface for a fiber-optic sensor array, as optic measurement principles tend to have a bulky interface. Mechanical, electrical and software approaches are combined to realize an integrated structure that provides decentralized data pre-processing of the tactile measurements. Local behaviors are implemented using this setup to show the effectiveness of this approach.

  16. Integration of Fiber-Optic Sensor Arrays into a Multi-Modal Tactile Sensor Processing System for Robotic End-Effectors

    Directory of Open Access Journals (Sweden)

    Peter Kampmann

    2014-04-01

    Full Text Available With the increasing complexity of robotic missions and the development towards long-term autonomous systems, the need for multi-modal sensing of the environment increases. Until now, the use of tactile sensor systems has been mostly based on sensing one modality of forces in the robotic end-effector. The use of a multi-modal tactile sensory system is motivated, which combines static and dynamic force sensor arrays together with an absolute force measurement system. This publication is focused on the development of a compact sensor interface for a fiber-optic sensor array, as optic measurement principles tend to have a bulky interface. Mechanical, electrical and software approaches are combined to realize an integrated structure that provides decentralized data pre-processing of the tactile measurements. Local behaviors are implemented using this setup to show the effectiveness of this approach.

  17. Sapphire ball lens-based fiber probe for common-path optical coherence tomography and its applications in corneal and retinal imaging.

    Science.gov (United States)

    Zhao, Mingtao; Huang, Yong; Kang, Jin U

    2012-12-01

    We describe a common-path swept source optical coherence tomography fiber probe design using a sapphire ball lens for cross-sectional imaging and sensing for retina vitrectomy surgery. The high refractive index (n=1.75) of the sapphire ball lens improves the focusing power and enables the probe to operate in the intraocular space. The highly precise spherical shape of the sapphire lens also reduces astigmatism and coma compared to fused nonspherical ball lenses. A theoretical sensitivity model for common-path optical coherence tomography (CP-OCT) was developed to assess its optimal performance based on an unbalanced photodetector configuration. Two probe designs-with working distances 415 and 1221 μm and lateral resolution 11 and 18 μm-were implemented with sensitivity up to 88 dB, which is significantly higher than previously reported CP-OCT probes. We assessed the performances of the fiber probes by cross-sectional imaging a bovine cornea and retina in air and in vitreous gel with a 1310 nm swept source OCT system. To the best of our knowledge, this is the first demonstration of sapphire ball lens-based CP-OCT probes directly inserted into the vitreous gel of a bovine eyeball for ocular imaging with a sensitivity approaching the theoretical limitation of CP-OCT.

  18. A liquid lens switching-based motionless variable fiber-optic delay line

    Science.gov (United States)

    Khwaja, Tariq Shamim; Reza, Syed Azer; Sheikh, Mumtaz

    2018-05-01

    We present a Variable Fiber-Optic Delay Line (VFODL) module capable of imparting long variable delays by switching an input optical/RF signal between Single Mode Fiber (SMF) patch cords of different lengths through a pair of Electronically Controlled Tunable Lenses (ECTLs) resulting in a polarization-independent operation. Depending on intended application, the lengths of the SMFs can be chosen accordingly to achieve the desired VFODL operation dynamic range. If so desired, the state of the input signal polarization can be preserved with the use of commercially available polarization-independent ECTLs along with polarization-maintaining SMFs (PM-SMFs), resulting in an output polarization that is identical to the input. An ECTL-based design also improves power consumption and repeatability. The delay switching mechanism is electronically-controlled, involves no bulk moving parts, and can be fully-automated. The VFODL module is compact due to the use of small optical components and SMFs that can be packaged compactly.

  19. Characterization of gradient-index lens-fiber spacing toward applications in two-photon fluorescence endoscopy

    Science.gov (United States)

    Fu, Ling; Gan, Xiaosong; Gu, Min

    2005-12-01

    We report on the experimental investigation into the characterization of two-photon fluorescence microscopy based on the separation distance of a single-mode optical fiber coupler and a gradient-index (GRIN) rod lens. The collected two-photon fluorescence signal exhibits a maximum intensity at a defined separation distance (gap length) where the increasing effective excitation numerical aperture is balanced by the decreasing confocal emission collection. A maximum signal is found at gap lengths of approximately 2, 1.25, and 1.75 mm for GRIN lenses with pitches of 0.23, 0.25, and 0.29 wavelength at 830 nm. The maximum two-photon fluorescence signal collected corresponds to a threefold reduction of axial resolution (38.5 µm at 1.25 mm), compared with the maximum resolution (11.6 µm at 5.5 mm), as shown by the three-dimensional imaging of 10 µm beads. These results demonstrate an intrinsic trade-off between signal collection and axial resolution.

  20. The Impact of Lens Opacity on SD-OCT Retinal Nerve Fiber Layer and Bruch's Membrane Opening Measurements Using the Anatomical Positioning System (APS).

    Science.gov (United States)

    Mauschitz, Matthias M; Roth, Felix; Holz, Frank G; Breteler, Monique M B; Finger, Robert P

    2017-05-01

    To evaluate the impact of lens opacity on retinal nerve fiber layer thickness (RNFLT) and Bruch's membrane opening (BMO) measurements. Fifty-nine randomly selected patients without any other relevant ocular pathology undergoing elective routine cataract surgery in two specialized eye clinics were enrolled. RNFLT, BMO area, and BMO minimum rim width (BMO-MRW) were assessed with the Heidelberg Engineering Spectralis OCT using the anatomical positioning system (APS) prior to and 1 day after cataract surgery using a ring scan at different eccentricities of the disc (3.5, 4.1 and 4.7 mm). Lens opacity was quantified using densitometry based on Scheimpflug images (Oculus Pentacam AXL). RNFLT, BMO area, and BMO-MRW were virtually identical before and following removal of the cataractous lens. This held when assessed overall, within the six sectors for the 3.5-mm scan, or at any other eccentricity. Baseline RNFLT was not associated with lens opacity. Using the APS, RNFLT remained unchanged following cataract surgery, contrary to results reported by previous studies. Our results imply that the APS may have contributed to more precise spectral-domain optical coherence measurements, minimizing the influence of cataract on RNFLT and BMO assessments in our cohort.

  1. Examination of tapered plastic multimode fiber-based sensor performance with silver coating for different concentrations of calcium hypochlorite by soft computing methodologies--a comparative study.

    Science.gov (United States)

    Zakaria, Rozalina; Sheng, Ong Yong; Wern, Kam; Shamshirband, Shahaboddin; Wahab, Ainuddin Wahid Abdul; Petković, Dalibor; Saboohi, Hadi

    2014-05-01

    A soft methodology study has been applied on tapered plastic multimode sensors. This study basically used tapered plastic multimode fiber [polymethyl methacrylate (PMMA)] optics as a sensor. The tapered PMMA fiber was fabricated using an etching method involving deionized water and acetone to achieve a waist diameter and length of 0.45 and 10 mm, respectively. In addition, a tapered PMMA probe, which was coated by silver film, was fabricated and demonstrated using a calcium hypochlorite (G70) solution. The working mechanism of such a device is based on the observation increment in the transmission of the sensor that is immersed in solutions at high concentrations. As the concentration was varied from 0 to 6 ppm, the output voltage of the sensor increased linearly. The silver film coating increased the sensitivity of the proposed sensor because of the effective cladding refractive index, which increases with the coating and thus allows more light to be transmitted from the tapered fiber. In this study, the polynomial and radial basis function (RBF) were applied as the kernel function of the support vector regression (SVR) to estimate and predict the output voltage response of the sensors with and without silver film according to experimental tests. Instead of minimizing the observed training error, SVR_poly and SVR_rbf were used in an attempt to minimize the generalization error bound so as to achieve generalized performance. An adaptive neuro-fuzzy interference system (ANFIS) approach was also investigated for comparison. The experimental results showed that improvements in the predictive accuracy and capacity for generalization can be achieved by the SVR_poly approach in comparison to the SVR_rbf methodology. The same testing errors were found for the SVR_poly approach and the ANFIS approach.

  2. Beam shaping element for compact fiber injection systems

    Energy Technology Data Exchange (ETDEWEB)

    Weichman, L.S.; Dickey, F.M.; Shagam, R.N.

    2000-01-05

    Injection of high power, multi-mode laser profiles into a fiber optic delivery system requires controlling a number of injection parameters to maximize throughput and minimize concerns for optical damage both at the entrance and exit faces of the fiber optic. A simple method for simultaneously achieving a compact fiber injection geometry and control of these injection parameters, independent of the input source characteristics, is provided by a refractive lenslet array and simple injection lens configuration. Design criteria together with analytical and experimental results for the refractive lenslet array and short focal length injection lens are presented. This arrangement provides a uniform spatial intensity distribution at the fiber injection plane to a large degree independent of the source mode structure, spatial profile, divergence, size, and/or alignment to the injection system. This technique has application to a number of laser systems where uniform illumination of a target or remote delivery of high peak power is desired.

  3. Tuning the dispersion and single/multimodeness in a hole-assisted fiber: a finite-element study

    NARCIS (Netherlands)

    Uranus, H.P.; Hoekstra, Hugo; van Groesen, Embrecht W.C.

    Using a vectorial finite element mode solver developed earlier, we studied a hole-assisted multi-ring fiber. We report the role of the holes in tuning the waveguide dispersion and the single/multi-modeness of the particular fiber. By correctly selecting the hole’s size and position, a single-mode

  4. Multi-modes interferometer for magnetic field and temperature measurement using Photonic crystal fiber filled with magnetic fluid

    Science.gov (United States)

    Li, Xue-gang; Zhou, Xue; Zhao, Yong; Lv, Ri-Qing

    2018-03-01

    An in-line modal Mach-Zehnder interferometer (MZI) based on a magnetic fluid-filled photonic crystal fiber (PCF) was proposed in this paper. The Mach-Zehnder interference was induced by the single mode fiber (SMF)-photonic crystal fiber (PCF)-single mode fiber (SMF) structure. And the photonic crystal fiber was filled with magnetic fluid to measure the magnetic field and temperature. There are multiple cladding modes are involved into the interference. Hence simultaneous measurement of temperature and refractive index can be achieved by simultaneously monitoring the two different modes interference spectra. The sensitivities of magnetic field and temperature can reach up to 0.072 nm/Gs and -0.080 nm/°C, respectively.

  5. Ectopic activation of Wnt/beta-catenin sgnaling in lens fiber cells results in cataract formation and aberrant fiber cell differentiation

    Czech Academy of Sciences Publication Activity Database

    Antošová, Barbora; Smolíková, Jana; Bořkovcová, Romana; Strnad, Hynek; Láchová, Jitka; Machoň, Ondřej; Kozmik, Zbyněk

    2013-01-01

    Roč. 8, č. 10 (2013), e78279 E-ISSN 1932-6203 R&D Projects: GA ČR GAP305/11/2198; GA ČR GAP305/12/2042; GA MŠk(CZ) LK11214; GA MŠk EE2.3.30.0027 Institutional support: RVO:68378050 Keywords : beta-catenin signaling * cataract * cell differentiation * lens * transcription factor * cyclin Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 3.534, year: 2013

  6. Fiber

    Science.gov (United States)

    ... for the treatment of diverticulosis , diabetes , and heart disease . ... fiber is found in oat bran, barley, nuts, seeds, beans, lentils, peas, ... heart disease. Insoluble fiber is found in foods such as ...

  7. Fiber

    Science.gov (United States)

    ... not getting enough fiber. According to the 2010 Dietary Guidelines, teen girls (14 to 18 years) should get 25 grams of fiber per day and teen boys (14 to 18 years) should get 31 grams of fiber per day. The best sources are fresh fruits and vegetables, nuts and legumes, ...

  8. Factors Determining the Oxygen Permeability of Biological Membranes: Oxygen Transport Across Eye Lens Fiber-Cell Plasma Membranes.

    Science.gov (United States)

    Subczynski, Witold Karol; Widomska, Justyna; Mainali, Laxman

    2017-01-01

    Electron paramagnetic resonance (EPR) spin-label oximetry allows the oxygen permeability coefficient to be evaluated across homogeneous lipid bilayer membranes and, in some cases, across coexisting membrane domains without their physical separation. The most pronounced effect on oxygen permeability is observed for cholesterol, which additionally induces the formation of membrane domains. In intact biological membranes, integral proteins induce the formation of boundary and trapped lipid domains with a low oxygen permeability. The effective oxygen permeability coefficient across the intact biological membrane is affected not only by the oxygen permeability coefficients evaluated for each lipid domain but also by the surface area occupied by these domains in the membrane. All these factors observed in fiber cell plasma membranes of clear human eye lenses are reviewed here.

  9. OAM-enhanced transmission for multimode short-range links

    DEFF Research Database (Denmark)

    Tatarczak, Anna; Usuga Castaneda, Mario A.; Tafur Monroy, Idelfonso

    2015-01-01

    We propose, experimentally demonstrate, and evaluate the performance of a multimode (MM) transmission fiber data link which is based on orbital angular momentum (OAM) modes. The proposed scheme uses OAM modes to increase capacity or reach without recurring to mode division multiplexing (MDM) or s...... interconnects and short range links that employ the existing multimode fiber infrastructure....

  10. Fiber optic coupled optical sensor

    Science.gov (United States)

    Fleming, Kevin J.

    2001-01-01

    A displacement sensor includes a first optical fiber for radiating light to a target, and a second optical fiber for receiving light from the target. The end of the first fiber is adjacent and not axially aligned with the second fiber end. A lens focuses light from the first fiber onto the target and light from the target onto the second fiber.

  11. Lens stem cells may reside outside the lens capsule: an hypothesis

    Directory of Open Access Journals (Sweden)

    Meyer Rita A

    2007-06-01

    Full Text Available Abstract In this paper, we consider the ocular lens in the context of contemporary developments in biological ideas. We attempt to reconcile lens biology with stem cell concepts and a dearth of lens tumors. Historically, the lens has been viewed as a closed system, in which cells at the periphery of the lens epithelium differentiate into fiber cells. Theoretical considerations led us to question whether the intracapsular lens is indeed self-contained. Since stem cells generate tumors and the lens does not naturally develop tumors, we reasoned that lens stem cells may not be present within the capsule. We hypothesize that lens stem cells reside outside the lens capsule, in the nearby ciliary body. Our ideas challenge the existing lens biology paradigm. We begin our discussion with lens background information, in order to describe our lens stem cell hypothesis in the context of published data. Then we present the ciliary body as a possible source for lens stem cells, and conclude by comparing the ocular lens with the corneal epithelium.

  12. Objective lens

    Science.gov (United States)

    Olczak, Eugene G. (Inventor)

    2011-01-01

    An objective lens and a method for using same. The objective lens has a first end, a second end, and a plurality of optical elements. The optical elements are positioned between the first end and the second end and are at least substantially symmetric about a plane centered between the first end and the second end.

  13. Multimodal Definition:

    African Journals Online (AJOL)

    user

    booming as a common tool of language learning and use. In the field of e-lexi- cography, such ... defining, as indicated under the entry of definition in Oxford Advanced Learner's. Dictionary of Current English (the ... In the above-mentioned context, this article argues for the establishment of the notion of multimodal definition ...

  14. Multimodal sensory integration in single cerebellar granule cells in vivo.

    Science.gov (United States)

    Ishikawa, Taro; Shimuta, Misa; Häusser, Michael

    2015-12-29

    The mammalian cerebellum is a highly multimodal structure, receiving inputs from multiple sensory modalities and integrating them during complex sensorimotor coordination tasks. Previously, using cell-type-specific anatomical projection mapping, it was shown that multimodal pathways converge onto individual cerebellar granule cells (Huang et al., 2013). Here we directly measure synaptic currents using in vivo patch-clamp recordings and confirm that a subset of single granule cells receive convergent functional multimodal (somatosensory, auditory, and visual) inputs via separate mossy fibers. Furthermore, we show that the integration of multimodal signals by granule cells can enhance action potential output. These recordings directly demonstrate functional convergence of multimodal signals onto single granule cells.

  15. Principal modes in multimode waveguides.

    Science.gov (United States)

    Fan, Shanhui; Kahn, Joseph M

    2005-01-15

    We generalize the concept of principal states of polarization and prove the existence of principal modes in multimode waveguides. Principal modes do not suffer from modal dispersion to first order of frequency variation and form orthogonal bases at both the input and the output ends of the waveguide. We show that principal modes are generally different from eigenmodes, even in uniform waveguides, unlike the special case of a single-mode fiber with uniform birefringence. The difference is most pronounced when different eigenmodes possess similar group velocities and when their field patterns vary as a function of frequency. This work may provide a new basis for analysis and control of dispersion in multimode fiber systems.

  16. Multimodality and Ambient Intelligence

    NARCIS (Netherlands)

    Nijholt, Antinus; Verhaegh, W.; Aarts, E.; Korst, J.

    2004-01-01

    In this chapter we discuss multimodal interface technology. We present eexamples of multimodal interfaces and show problems and opportunities. Fusion of modalities is discussed and some roadmap discussions on research in multimodality are summarized. This chapter also discusses future developments

  17. A portable confocal hyperspectral microscope without any scan or tube lens and its application in fluorescence and Raman spectral imaging

    Science.gov (United States)

    Li, Jingwei; Cai, Fuhong; Dong, Yongjiang; Zhu, Zhenfeng; Sun, Xianhe; Zhang, Hequn; He, Sailing

    2017-06-01

    In this study, a portable confocal hyperspectral microscope is developed. In traditional confocal laser scanning microscopes, scan lens and tube lens are utilized to achieve a conjugate relationship between the galvanometer and the back focal plane of the objective, in order to achieve a better resolution. However, these lenses make it difficult to scale down the volume of the system. In our portable confocal hyperspectral microscope (PCHM), the objective is placed directly next to the galvomirror. Thus, scan lens and tube lens are not included in our system and the size of this system is greatly reduced. Furthermore, the resolution is also acceptable in many biomedical and food-safety applications. Through reducing the optical length of the system, the signal detection efficiency is enhanced. This is conducive to realizing both the fluorescence and Raman hyperspectral imaging. With a multimode fiber as a pinhole, an improved image contrast is also achieved. Fluorescent spectral images for HeLa cells/fingers and Raman spectral images of kumquat pericarp are present. The spectral resolution and spatial resolutions are about 0.4 nm and 2.19 μm, respectively. These results demonstrate that this portable hyperspectral microscope can be used in in-vivo fluorescence imaging and in situ Raman spectral imaging.

  18. αA-crystallin R49Cneo mutation influences the architecture of lens fiber cell membranes and causes posterior and nuclear cataracts in mice

    Directory of Open Access Journals (Sweden)

    Andley Usha P

    2009-07-01

    Full Text Available Abstract Background αA-crystallin (CRYAA/HSPB4, a major component of all vertebrate eye lenses, is a small heat shock protein responsible for maintaining lens transparency. The R49C mutation in the αA-crystallin protein is linked with non-syndromic, hereditary human cataracts in a four-generation Caucasian family. Methods This study describes a mouse cataract model generated by insertion of a neomycin-resistant (neor gene into an intron of the gene encoding mutant R49C αA-crystallin. Mice carrying the neor gene and wild-type Cryaa were also generated as controls. Heterozygous knock-in mice containing one wild type gene and one mutated gene for αA-crystallin (WT/R49Cneo and homozygous knock-in mice containing two mutated genes (R49Cneo/R49Cneo were compared. Results By 3 weeks, WT/R49Cneo mice exhibited large vacuoles in the cortical region 100 μm from the lens surface, and by 3 months posterior and nuclear cataracts had developed. WT/R49Cneo mice demonstrated severe posterior cataracts at 9 months of age, with considerable posterior nuclear migration evident in histological sections. R49Cneo/R49Cneo mice demonstrated nearly complete lens opacities by 5 months of age. In contrast, R49C mice in which the neor gene was deleted by breeding with CreEIIa mice developed lens abnormalities at birth, suggesting that the neor gene may suppress expression of mutant R49C αA-crystallin protein. Conclusion It is apparent that modification of membrane and cell-cell interactions occurs in the presence of the αA-crystallin mutation and rapidly leads to lens cell pathology in vivo.

  19. Lens Model

    DEFF Research Database (Denmark)

    Nash, Ulrik William

    2014-01-01

    Firms consist of people who make decisions to achieve goals. How do these people develop the expectations which underpin the choices they make? The lens model provides one answer to this question. It was developed by cognitive psychologist Egon Brunswik (1952) to illustrate his theory...

  20. Efficient multi-mode to single-mode conversion in a 61 port photonic lantern

    DEFF Research Database (Denmark)

    Noordegraaf, Danny; Skovgaard, Peter M. W.; Dybendahl Maack, Martin

    2010-01-01

    We demonstrate the fabrication of a multi-mode (MM) to 61 port single-mode (SM) splitter or "Photonic Lantern". Low port count Photonic Lanterns were first described by Leon-Saval et al. (2005). These are based on a photonic crystal fiber type design, with air-holes defining the multi-mode fiber ...... of astrophotonics for coupling MM star-light to an ensemble of SM fibers in order to perform fiber Bragg grating based spectral filtering....

  1. Development of a micromirror-scanned multimodal CARS miniaturized microscope for the in vivo study of spinal cord disorders

    Science.gov (United States)

    Murugkar, Sangeeta; Smith, Brett; Naji, Majid; Brideau, Craig; Stys, Peter; Anis, Hanan

    2011-03-01

    We discuss the design and implementation of a novel multimodal coherent anti-Stokes Raman scattering (CARS) miniaturized microscope for imaging of injured and recovering spinal cords in a single living animal. We demonstrate for the first time, the use of a biaxial microelectromechanical system (MEMS) mirror for scanning and diffraction limited multiple lens miniaturized objective for exciting a CARS signal. The miniaturized microscope design includes light delivery using a large mode area photonic crystal fiber (PCF), and multimode fiber for collection of the nonlinear optical signal. The basic design concept, major engineering challenges, solutions, and preliminary results are presented. We demonstrate CARS and two photon excitation fluorescence microscopy in a benchtop setup with the miniaturized optics and MEMS scanning. The light source is based on a single femtosecond laser (pump beam) and a supercontinuum generated in a nonlinear PCF (Stokes beam). This is coupled using free space optics onto the surface of a resonantly driven two dimensional scanning MEMS mirror that scans the excitation light in a Lissajous pattern. The novel design of the miniaturized microscope is expected to provide significant new information on the pathogenesis of demyelinating diseases such as Multiple Sclerosis and Spinal Cord Injury.

  2. Acoustic lens for capacitive micromachined ultrasonic transducers

    Science.gov (United States)

    Chang, Chienliu; Firouzi, Kamyar; Park, Kwan Kyu; Sarioglu, Ali Fatih; Nikoozadeh, Amin; Yoon, Hyo-Seon; Vaithilingam, Srikant; Carver, Thomas; Khuri-Yakub, Butrus T.

    2014-08-01

    Capacitive micromachined ultrasonic transducers (CMUTs) have great potential to compete with traditional piezoelectric transducers in therapeutic ultrasound applications. In this paper we have designed, fabricated and developed an acoustic lens formed on the CMUT to mechanically focus ultrasound. The acoustic lens was designed based on the paraxial theory and made of silicone rubber for acoustic impedance matching and encapsulation. The CMUT was fabricated based on the local oxidation of silicon (LOCOS) and fusion-bonding. The fabricated CMUT was verified to behave like an electromechanical resonator in air and exhibited wideband response with a center frequency of 2.2 MHz in immersion. The fabrication for the acoustic lens contained two consecutive mold castings and directly formed on the surface of the CMUT. Applied with ac burst input voltages at the center frequency, the CMUT with the acoustic lens generated an output pressure of 1.89 MPa (peak-to-peak) at the focal point with an effective focal gain of 3.43 in immersion. Compared to the same CMUT without a lens, the CMUT with the acoustic lens demonstrated the ability to successfully focus ultrasound and provided a viable solution to the miniaturization of the multi-modality forward-looking endoscopes without electrical focusing.

  3. Acoustic lens for capacitive micromachined ultrasonic transducers

    International Nuclear Information System (INIS)

    Chang, Chienliu; Firouzi, Kamyar; Sarioglu, Ali Fatih; Nikoozadeh, Amin; Yoon, Hyo-Seon; Vaithilingam, Srikant; Carver, Thomas; Khuri-Yakub, Butrus T; Kyu Park, Kwan

    2014-01-01

    Capacitive micromachined ultrasonic transducers (CMUTs) have great potential to compete with traditional piezoelectric transducers in therapeutic ultrasound applications. In this paper we have designed, fabricated and developed an acoustic lens formed on the CMUT to mechanically focus ultrasound. The acoustic lens was designed based on the paraxial theory and made of silicone rubber for acoustic impedance matching and encapsulation. The CMUT was fabricated based on the local oxidation of silicon (LOCOS) and fusion-bonding. The fabricated CMUT was verified to behave like an electromechanical resonator in air and exhibited wideband response with a center frequency of 2.2 MHz in immersion. The fabrication for the acoustic lens contained two consecutive mold castings and directly formed on the surface of the CMUT. Applied with ac burst input voltages at the center frequency, the CMUT with the acoustic lens generated an output pressure of 1.89 MPa (peak-to-peak) at the focal point with an effective focal gain of 3.43 in immersion. Compared to the same CMUT without a lens, the CMUT with the acoustic lens demonstrated the ability to successfully focus ultrasound and provided a viable solution to the miniaturization of the multi-modality forward-looking endoscopes without electrical focusing. (paper)

  4. Use of optical fibers in spectrophotometry

    Science.gov (United States)

    Ramsey, Lawrence W.

    1988-01-01

    The use of single or small numbers of fiber optic fibers in astronomical spectroscopy with the goal of greater spectrophotometric and radial velocity accuracy is discussed. The properties of multimode step index fibers which are most important for this application are outlined, as are laboratory tests of currently available fibers.

  5. Label-free imaging and quantitative chemical analysis of Alzheimer's disease brain samples with multimodal multiphoton nonlinear optical microspectroscopy

    Science.gov (United States)

    Lee, Jang Hyuk; Kim, Dae Hwan; Song, Woo Keun; Oh, Myoung-Kyu; Ko, Do-Kyeong

    2015-05-01

    We developed multimodal multiphoton microspectroscopy using a small-diameter probe with gradient-index lenses and applied it to unstained Alzheimer's disease (AD) brain samples. Our system maintained the image quality and spatial resolution of images obtained using an objective lens of similar numerical aperture. Multicolor images of AD brain samples were obtained simultaneously by integrating two-photon excited fluorescence and second-harmonic generation on a coherent anti-Stokes Raman scattering (CARS) microendoscope platform. Measurements of two hippocampal regions, the cornus ammonis-1 and dentate gyrus, revealed more lipids, amyloid fibers, and collagen in the AD samples than in the normal samples. Normal and AD brains were clearly distinguished by a large spectral difference and quantitative analysis of the CH mode using CARS microendoscope spectroscopy. We expect this system to be an important diagnosis tool in AD research.

  6. Role of Aquaporin 0 in lens biomechanics

    Energy Technology Data Exchange (ETDEWEB)

    Sindhu Kumari, S.; Gupta, Neha [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); Shiels, Alan [Washington University School of Medicine, St. Louis, MO (United States); FitzGerald, Paul G. [Cell Biology and Human Anatomy, School of Medicine, University of California, Davis, CA (United States); Menon, Anil G. [University of Cincinnati College of Medicine, Cincinnati, OH (United States); Mathias, Richard T. [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States); Varadaraj, Kulandaiappan, E-mail: kulandaiappan.varadaraj@stonybrook.edu [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States)

    2015-07-10

    Maintenance of proper biomechanics of the eye lens is important for its structural integrity and for the process of accommodation to focus near and far objects. Several studies have shown that specialized cytoskeletal systems such as the beaded filament (BF) and spectrin-actin networks contribute to mammalian lens biomechanics; mutations or deletion in these proteins alters lens biomechanics. Aquaporin 0 (AQP0), which constitutes ∼45% of the total membrane proteins of lens fiber cells, has been shown to function as a water channel and a structural cell-to-cell adhesion (CTCA) protein. Our recent ex vivo study on AQP0 knockout (AQP0 KO) mouse lenses showed the CTCA function of AQP0 could be crucial for establishing the refractive index gradient. However, biomechanical studies on the role of AQP0 are lacking. The present investigation used wild type (WT), AQP5 KO (AQP5{sup −/−}), AQP0 KO (heterozygous KO: AQP0{sup +/−}; homozygous KO: AQP0{sup −/−}; all in C57BL/6J) and WT-FVB/N mouse lenses to learn more about the role of fiber cell AQPs in lens biomechanics. Electron microscopic images exhibited decreases in lens fiber cell compaction and increases in extracellular space due to deletion of even one allele of AQP0. Biomechanical assay revealed that loss of one or both alleles of AQP0 caused a significant reduction in the compressive load-bearing capacity of the lenses compared to WT lenses. Conversely, loss of AQP5 did not alter the lens load-bearing ability. Compressive load-bearing at the suture area of AQP0{sup +/−} lenses showed easy separation while WT lens suture remained intact. These data from KO mouse lenses in conjunction with previous studies on lens-specific BF proteins (CP49 and filensin) suggest that AQP0 and BF proteins could act co-operatively in establishing normal lens biomechanics. We hypothesize that AQP0, with its prolific expression at the fiber cell membrane, could provide anchorage for cytoskeletal structures like BFs and

  7. Contact lens in keratoconus

    Directory of Open Access Journals (Sweden)

    Varsha M Rathi

    2013-01-01

    Full Text Available Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP lenses, soft and soft toric lenses, piggy back contact lenses (PBCL, hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the English language with the keywords keratoconus and various contact lenses such as Rose k lens, RGP lens, hybrid lens, scleral lens and PBCL.

  8. Contact lens in keratoconus

    Science.gov (United States)

    Rathi, Varsha M; Mandathara, Preeji S; Dumpati, Srikanth

    2013-01-01

    Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP) lenses, soft and soft toric lenses, piggy back contact lenses (PBCL), hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the English language with the keywords keratoconus and various contact lenses such as Rose k lens, RGP lens, hybrid lens, scleral lens and PBCL. PMID:23925325

  9. Behaviour of a few mode fiber modal pattern under stress

    Science.gov (United States)

    Egalon, Claudio O.; Rogowski, Robert S.

    1991-01-01

    A numerical model was developed to calculate the interference pattern at the end of a multimode weakly guiding optical fiber under stress. Whenever an optical fiber is under stress, the modal phase in the interference term of the intensity formula changes. Plots of the simulated output of a stressed fiber are presented. For multimode fibers, very complicated patterns result. Under stress, lobes in the pattern are generated, displaced and power is exchanged among them.

  10. Low dose rate gamma ray induced loss and data error rate of multimode silica fibre links

    International Nuclear Information System (INIS)

    Breuze, G.; Fanet, H.; Serre, J.

    1993-01-01

    Fiber optics data transmission from numerous multiplexed sensors, is potentially attractive for nuclear plant applications. Multimode silica fiber behaviour during steady state gamma ray exposure is studied as a joint programme between LETI CE/SACLAY and EDF Renardieres: transmitted optical power and bit error rate have been measured on a 100 m optical fiber

  11. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... lens because they can be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, ... Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume Contacts May Contain Chemicals Harmful to Eyes ...

  12. Multimodality in organization studies

    DEFF Research Database (Denmark)

    Van Leeuwen, Theo

    2017-01-01

    This afterword reviews the chapters in this volume and reflects on the synergies between organization and management studies and multimodality studies that emerge from the volume. These include the combination of strong sociological theorizing and detailed multimodal analysis, a focus on material...

  13. Multimodal fluorescence imaging spectroscopy

    NARCIS (Netherlands)

    Stopel, Martijn H W; Blum, Christian; Subramaniam, Vinod; Engelborghs, Yves; Visser, Anthonie J.W.G.

    2014-01-01

    Multimodal fluorescence imaging is a versatile method that has a wide application range from biological studies to materials science. Typical observables in multimodal fluorescence imaging are intensity, lifetime, excitation, and emission spectra which are recorded at chosen locations at the sample.

  14. Critical Analysis of Multimodal Discourse

    DEFF Research Database (Denmark)

    van Leeuwen, Theo

    2013-01-01

    This is an encyclopaedia article which defines the fields of critical discourse analysis and multimodality studies, argues that within critical discourse analysis more attention should be paid to multimodality, and within multimodality to critical analysis, and ends reviewing a few examples...... of recent work in the critical analysis of multimodal discourse....

  15. Optical fibers for communication.

    Science.gov (United States)

    Gloge, D

    1974-02-01

    The transparency of glass fibers in the visible and near infrared-improved beyond all expectations by recent breakthroughs-seems now sufficient to transmit optical signals unprocessed over miles. No wonder that efforts have intensified all over the world to utilize fibers in future communication systems. Materials research and fabrication are the fields where present progress is most rapid. New ways of preform preparation by deposition, doping, or diffusion are being studied and found to offer improvements and versatility. As far as materials are concerned, fused silica has shown the lowest bulk losses and hence receives the most interest, but many glasses are being studied as well. As new processes become available and record lows in fiber loss are being reached, propagation theory is finding new challenges as well. On the one hand, multimode fibers seem desirable with respect to transmitter compatibility, splicing, and fabrication tolerances. On the other hand, the signal distortion caused by mode delay differences in multimode fibers can be considerable and requires equalization-inherent in the fiber or at the fiber end. Beyond that, the wavelength dependence of the refractive index produces dispersion effects serious enough to be of importance. Thinking ahead, one is confronted with the question of fiber handling, strength, and life. The technology of making cables and splices from a brittle material like glass is in its infancy, and we can only indicate the extent of these difficult problems ahead.

  16. Multimodal Processes Rescheduling

    DEFF Research Database (Denmark)

    Bocewicz, Grzegorz; Banaszak, Zbigniew A.; Nielsen, Peter

    2013-01-01

    Cyclic scheduling problems concerning multimodal processes are usually observed in FMSs producing multi-type parts where the Automated Guided Vehicles System (AGVS) plays a role of a material handling system. Schedulability analysis of concurrently flowing cyclic processes (SCCP) exe...

  17. Multimodal freight investment criteria.

    Science.gov (United States)

    2010-07-01

    Literature was reviewed on multi-modal investment criteria for freight projects, examining measures and techniques for quantifying project benefits and costs, as well as ways to describe the economic importance of freight transportation. : A limited ...

  18. REFRACTIVE NEUTRON LENS

    OpenAIRE

    Petrov, P. V.; Kolchevsky, N. N.

    2013-01-01

    Compound concave refractive lenses are used for focusing neutron beam. Investigations of spectral and focusing properties of a refractive neutron lens are presented. Resolution of the imaging system on the base of refractive neutron lenses depends on material properties and parameters of neutron source. Model of refractive neutron lens are proposed. Results of calculation diffraction resolution and focal depth of refractive neutron lens are discussed.

  19. Contact lens in keratoconus

    OpenAIRE

    Rathi, Varsha M; Mandathara, Preeji S; Dumpati, Srikanth

    2013-01-01

    Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP) lenses, soft and soft toric lenses, piggy back contact lenses (PBCL), hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the En...

  20. Multi-focus beam shaping of high power multimode lasers

    Science.gov (United States)

    Laskin, Alexander; Volpp, Joerg; Laskin, Vadim; Ostrun, Aleksei

    2017-08-01

    Beam shaping of powerful multimode fiber lasers, fiber-coupled solid-state and diode lasers is of great importance for improvements of industrial laser applications. Welding, cladding with millimetre scale working spots benefit from "inverseGauss" intensity profiles; performance of thick metal sheet cutting, deep penetration welding can be enhanced when distributing the laser energy along the optical axis as more efficient usage of laser energy, higher edge quality and reduction of the heat affected zone can be achieved. Building of beam shaping optics for multimode lasers encounters physical limitations due to the low beam spatial coherence of multimode fiber-coupled lasers resulting in big Beam Parameter Products (BPP) or M² values. The laser radiation emerging from a multimode fiber presents a mixture of wavefronts. The fiber end can be considered as a light source which optical properties are intermediate between a Lambertian source and a single mode laser beam. Imaging of the fiber end, using a collimator and a focusing objective, is a robust and widely used beam delivery approach. Beam shaping solutions are suggested in form of optics combining fiber end imaging and geometrical separation of focused spots either perpendicular to or along the optical axis. Thus, energy of high power lasers is distributed among multiple foci. In order to provide reliable operation with multi-kW lasers and avoid damages the optics are designed as refractive elements with smooth optical surfaces. The paper presents descriptions of multi-focus optics as well as examples of intensity profile measurements of beam caustics and application results.

  1. Early Years Teachers' Perspectives on Teaching through Multiple Metaphors and Multimodality

    Science.gov (United States)

    Mildenhall, Paula

    2015-01-01

    Recent research findings indicate that using multiple metaphors in multimodal learning experiences are effective teaching approaches in early years mathematics. Using a social semiotic lens this paper reports on eight early years teachers' perceptions of this approach whilst engaging in a small collaborative professional learning group. This group…

  2. Multimodal Resources in Transnational Adoption

    DEFF Research Database (Denmark)

    Raudaskoski, Pirkko Liisa

    The paper discusses an empirical analysis which highlights the multimodal nature of identity construction. A documentary on transnational adoption provides real life incidents as research material. The incidents involve (or from them emerge) various kinds of multimodal resources and participants...

  3. Diffraction enhanced X-ray imaging of mammals crystalline lens

    Energy Technology Data Exchange (ETDEWEB)

    Antunes, A. [Departamento de Fisica Aplicada, USP, CP 66318, 05315-970 Sao Paulo, SP (Brazil)]. E-mail: antunes@if.usp.br; Hoennicke, M.G. [LORXI, Departamento de Fisica, Universidade Federal do Parana, Curitiba (Brazil); Safatle, A.M.V. [Faculdade de Medicina Veterinaria e Zootecnia, USP, 05508-900 Sao Paulo, SP (Brazil); Cusatis, C. [LORXI, Departamento de Fisica, Universidade Federal do Parana, Curitiba (Brazil); Moraes Barros, P.S. [Faculdade de Medicina Veterinaria e Zootecnia, USP, 05508-900 Sao Paulo, SP (Brazil); Morelhao, S.L. [Departamento de Fisica Aplicada, USP, CP 66318, 05315-970 Sao Paulo, SP (Brazil)

    2005-08-15

    Crystalline lenses are transparent biological materials where the organization of the lens fibers can also be affected by changes at molecular level, and therefore the structure and morphology of the tissue can be correlated to the loss of transparency of the lens. In this work, internal structure of mammal lenses regarding the long-range ordering of the fibers are investigated by diffraction enhanced X-ray imaging (DEI) radiography. Moreover, DEI and absorption X-ray synchrotron radiographs for healthy and cataractous crystalline lenses are compared. Significant differences in healthy and cataractous crystalline lenses are observed.

  4. Diffraction enhanced X-ray imaging of mammals crystalline lens

    International Nuclear Information System (INIS)

    Antunes, A.; Hoennicke, M.G.; Safatle, A.M.V.; Cusatis, C.; Moraes Barros, P.S.; Morelhao, S.L.

    2005-01-01

    Crystalline lenses are transparent biological materials where the organization of the lens fibers can also be affected by changes at molecular level, and therefore the structure and morphology of the tissue can be correlated to the loss of transparency of the lens. In this work, internal structure of mammal lenses regarding the long-range ordering of the fibers are investigated by diffraction enhanced X-ray imaging (DEI) radiography. Moreover, DEI and absorption X-ray synchrotron radiographs for healthy and cataractous crystalline lenses are compared. Significant differences in healthy and cataractous crystalline lenses are observed

  5. QUARTZ FIBER ELECTROSCOPES

    Science.gov (United States)

    Henderson, R.P.

    1957-09-17

    An instrument carried unobtrusively about the person such as in a finger ring to indicate when that person has been exposed to an unusual radiation hazard is described. A metallized quartz fiber is electrically charged to indicate a full scale reading on an etched glass background. The quartz fiber and the scale may be viewed through a magnifying lens for ease of reading. Incident radiation will ionize gaseous particles in the sealed structure thereby allowing the charge to leak off the quartz fiber with its resulting movement across the scale proportionally indicating the radiation exposure.

  6. Modeling Multimodal Stratification

    DEFF Research Database (Denmark)

    Boeriis, Morten

    2017-01-01

    This article discusses one of the core axioms of social semiotic theory, namely stratification, in the light of developments in multimodality in recent years. The discussion takes a point of departure in the approaches to stratification taken by Hjelmslev, Halliday, and Kress and van Leeuwen....... The article outlines a theoretical experiment exploring how an alternative way of modeling stratification and instantiation may raise some interesting ideas on the concepts of realization dynamics, system-instance, and the different contexts of the semiotic text. This is elaborated in a discussion of how...... the relationship between stratification and instantiation in the multimodal instantiation of resources at different strata may provide a new approach to mapping out the dynamics of multimodal meaning making....

  7. Aquaporin 0 plays a pivotal role in refractive index gradient development in mammalian eye lens to prevent spherical aberration

    Energy Technology Data Exchange (ETDEWEB)

    Kumari, S. Sindhu [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); Varadaraj, Kulandaiappan, E-mail: kulandaiappan.varadaraj@stonybrook.edu [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, New York, NY (United States)

    2014-10-03

    Highlights: • Intact AQP0 functions as fiber cell-to-fiber cell adhesion protein. • AQP0 facilitates reduction in extracellular space and lens water content. • AQP0 adhesion function aids in lens refractive index gradient (RING) formation. • AQP0 prevents lens spherical aberration by establishing RING. • AQP0 is critical for lens transparency and homeostasis. - Abstract: Aquaporin 0 (AQP0) is a transmembrane channel that constitutes ∼45% of the total membrane protein of the fiber cells in mammalian lens. It is critical for lens transparency and homeostasis as mutations and knockout cause autosomal dominant lens cataract. AQP0 functions as a water channel and as a cell-to-cell adhesion (CTCA) molecule in the lens. Our recent in vitro studies showed that the CTCA function of AQP0 could be crucial to establish lens refractive index gradient (RING). However, there is a lack of in vivo data to corroborate the role of AQP0 as a fiber CTCA molecule which is critical for creating lens RING. The present investigation is undertaken to gather in vivo evidence for the involvement of AQP0 in developing lens RING. Lenses of wild type (WT) mouse, AQP0 knockout (heterozygous, AQP0{sup +/−}) and AQP0 knockout lens transgenically expressing AQP1 (heterozygous AQP0{sup +/−}/AQP1{sup +/−}) mouse models were used for the study. Data on AQP0 protein profile of intact and N- and/or C-terminal cleaved AQP0 in the lens by MALDI-TOF mass spectrometry and SDS–PAGE revealed that outer cortex fiber cells have only intact AQP0 of ∼28 kDa, inner cortical and outer nuclear fiber cells have both intact and cleaved forms, and inner nuclear fiber cells have only cleaved forms (∼26–24 kDa). Knocking out of 50% of AQP0 protein caused light scattering, spherical aberration (SA) and cataract. Restoring the lost fiber cell membrane water permeability (P{sub f}) by transgene AQP1 did not reinstate complete lens transparency and the mouse lenses showed light scattering and SA

  8. Multimodality imaging techniques.

    Science.gov (United States)

    Martí-Bonmatí, Luis; Sopena, Ramón; Bartumeus, Paula; Sopena, Pablo

    2010-01-01

    In multimodality imaging, the need to combine morphofunctional information can be approached by either acquiring images at different times (asynchronous), and fused them through digital image manipulation techniques or simultaneously acquiring images (synchronous) and merging them automatically. The asynchronous post-processing solution presents various constraints, mainly conditioned by the different positioning of the patient in the two scans acquired at different times in separated machines. The best solution to achieve consistency in time and space is obtained by the synchronous image acquisition. There are many multimodal technologies in molecular imaging. In this review we will focus on those multimodality image techniques more commonly used in the field of diagnostic imaging (SPECT-CT, PET-CT) and new developments (as PET-MR). The technological innovations and development of new tracers and smart probes are the main key points that will condition multimodality image and diagnostic imaging professionals' future. Although SPECT-CT and PET-CT are standard in most clinical scenarios, MR imaging has some advantages, providing excellent soft-tissue contrast and multidimensional functional, structural and morphological information. The next frontier is to develop efficient detectors and electronics systems capable of detecting two modality signals at the same time. Not only PET-MR but also MR-US or optic-PET will be introduced in clinical scenarios. Even more, MR diffusion-weighted, pharmacokinetic imaging, spectroscopy or functional BOLD imaging will merge with PET tracers to further increase molecular imaging as a relevant medical discipline. Multimodality imaging techniques will play a leading role in relevant clinical applications. The development of new diagnostic imaging research areas, mainly in the field of oncology, cardiology and neuropsychiatry, will impact the way medicine is performed today. Both clinical and experimental multimodality studies, in

  9. Multimodal Strategies of Theorization

    DEFF Research Database (Denmark)

    Cartel, Melodie; Colombero, Sylvain; Boxenbaum, Eva

    This paper examines the role of multimodal strategies in processes of theorization. Empirically, we investigate the theorization process of a highly disruptive innovation in the history of architecture: reinforced concrete. Relying on archival data from a dominant French architectural journal from...... with well-known rhetorical strategies and develop a process model of theorization....... 1885 to 1939, we studied how this new material became legitimized for the construction of buildings. Our early coding revealed three multimodal strategies associated with theorization: emotional, narrative, and lexical. Our intention when developing the full paper is to articulate these findings...

  10. Multimodal news framing effects

    NARCIS (Netherlands)

    Powell, T.E.

    2017-01-01

    Visuals in news media play a vital role in framing citizens’ political preferences. Yet, compared to the written word, visual images are undervalued in political communication research. Using framing theory, this thesis redresses the balance by studying the combined, or multimodal, effects of visual

  11. Multimodal training between agents

    DEFF Research Database (Denmark)

    Rehm, Matthias

    2003-01-01

    In the system Locator1, agents are treated as individual and autonomous subjects that are able to adapt to heterogenous user groups. Applying multimodal information from their surroundings (visual and linguistic), they acquire the necessary concepts for a successful interaction. This approach has...

  12. Multimodal Strategies of Theorization

    DEFF Research Database (Denmark)

    Cartel, Melodie; Colombero, Sylvain; Boxenbaum, Eva

    This paper examines the role of multimodal strategies in processes of theorization. Empirically, we investigate the theorization process of a highly disruptive innovation in the history of architecture: reinforced concrete. Relying on archival data from a dominant French architectural journal from...

  13. Etude des architectures optiques pour le réseau local domestique, basées sur la fibre multimode (polymère et silice) et le multiplexage en longueur d’onde

    OpenAIRE

    Richard , Francis

    2012-01-01

    Only optical fiber is able to meet capacity and heterogeneity requirements of the future home network. Plastic or silica multimode fiber would be preferred for lower system costs. Two main multiformat architectures have been identified, based on an active or a passive star. Silica multimode fiber is suitable for an active star but plastic fiber could also be eligible, with its very low cost. Unfortunately, its bandwidth is far too limited. Solutions to increase its capacity, such as wavelengt...

  14. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... new application of artificial intelligence shows whether a patient’s eyes point to high blood pressure or risk ...

  15. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... ask for a prescription. There is no such thing as a "one size fits all" contact lens. ...

  16. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... had not been properly fitted by an eye care professional, the lenses stuck to my eye like ... lenses do not require the same level of care or consideration as a standard contact lens because ...

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her ...

  18. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... Costume Contact Lenses Can Ruin Vision Eye Makeup Safety In fact, it is illegal to sell colored ...

  19. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... with Colored Contact Lenses Julian: Teenager Blinded In One Eye By Non-Prescription Contact Lens Laura: Vision ... Robyn: Blurry Vision and Daily Eye Drops After One Use Facts About Colored Contacts and Halloween Safety ...

  20. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of Service For ...

  1. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... in a pair of colored contact lenses, Laura Butler of Parkersburg, W.Va., had "extreme pain in ... to wear any kind of contact lens. In Butler's case, the lenses caused an infection and left ...

  2. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses ...

  3. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... an impulsive buy from a souvenir shop, but 10 hours after she first put in a pair ... Prescription Contact Lens Laura: Vision Loss After Just 10 Hours Robyn: Blurry Vision and Daily Eye Drops ...

  4. bubble chamber lens

    CERN Multimedia

    Before the days of electronic detectors, visual techniques were used to detect particles, using detectors such as spark chambers and bubble chambers. This plexiglass lens was used to focus the image of tracks so they could be photographed.

  5. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Contact Lens Facts Over-the-Counter Costume Contacts May Contain Chemicals Harmful to Eyes Four Ways Over- ... without a prescription are breaking the law, and may be fined $11,000 per violation. "Many of ...

  6. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not require the same level of care or consideration as a standard contact lens because they can ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ...

  7. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... an ophthalmologist — an eye medical doctor — who will measure each eye and talk to you about proper ...

  8. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... prescription. Follow the contact lens care directions for cleaning, disinfecting, and wearing the lenses. Never share contact ... with Industry Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  9. Viscous froth lens

    Science.gov (United States)

    Green, T. E.; Bramley, A.; Lue, L.; Grassia, P.

    2006-11-01

    Microscale models of foam structure traditionally incorporate a balance between bubble pressures and surface tension forces associated with curvature of bubble films. In particular, models for flowing foam microrheology have assumed this balance is maintained under the action of some externally imposed motion. Recently, however, a dynamic model for foam structure has been proposed, the viscous froth model, which balances the net effect of bubble pressures and surface tension to viscous dissipation forces: this permits the description of fast-flowing foam. This contribution examines the behavior of the viscous froth model when applied to a paradigm problem with a particularly simple geometry: namely, a two-dimensional bubble “lens.” The lens consists of a channel partly filled by a bubble (known as the “lens bubble”) which contacts one channel wall. An additional film (known as the “spanning film”) connects to this bubble spanning the distance from the opposite channel wall. This simple structure can be set in motion and deformed out of equilibrium by applying a pressure across the spanning film: a rich dynamical behavior results. Solutions for the lens structure steadily propagating along the channel can be computed by the viscous froth model. Perturbation solutions are obtained in the limit of a lens structure with weak applied pressures, while numerical solutions are available for higher pressures. These steadily propagating solutions suggest that small lenses move faster than large ones, while both small and large lens bubbles are quite resistant to deformation, at least for weak applied back pressures. As the applied back pressure grows, the structure with the small lens bubble remains relatively stiff, while that with the large lens bubble becomes much more compliant. However, with even further increases in the applied back pressure, a critical pressure appears to exist for which the steady-state structure loses stability and unsteady

  10. Multimodal eye recognition

    Science.gov (United States)

    Zhou, Zhi; Du, Yingzi; Thomas, N. L.; Delp, Edward J., III

    2010-04-01

    Multimodal biometrics use more than one means of biometric identification to achieve higher recognition accuracy, since sometimes a unimodal biometric is not good enough used to do identification and classification. In this paper, we proposed a multimodal eye recognition system, which can obtain both iris and sclera patterns from one color eye image. Gabor filter and 1-D Log-Gabor filter algorithms have been applied as the iris recognition algorithms. In sclera recognition, we introduced automatic sclera segmentation, sclera pattern enhancement, sclera pattern template generation, and sclera pattern matching. We applied kernelbased matching score fusion to improve the performance of the eye recognition system. The experimental results show that the proposed eye recognition method can achieve better performance compared to unimodal biometric identification, and the accuracy of our proposed kernel-based matching score fusion method is higher than two classic linear matching score fusion methods: Principal Component Analysis (PCA) and Linear Discriminant Analysis (LDA).

  11. DSP-Based Focusing over Optical Fiber Using Time Reversal

    DEFF Research Database (Denmark)

    Piels, Molly; Porto da Silva, Edson; Estaran Tolosa, Jose Manuel

    2014-01-01

    A time-reversal array in multimode fiber is proposed for lossless switching using passive optical splitters. Numerical investigations are performed, and a two-transmitter array that routes a 3GBd QPSK signal through the physical layer is demonstrated experimentally.......A time-reversal array in multimode fiber is proposed for lossless switching using passive optical splitters. Numerical investigations are performed, and a two-transmitter array that routes a 3GBd QPSK signal through the physical layer is demonstrated experimentally....

  12. Tinnitus Multimodal Imaging

    Science.gov (United States)

    2016-12-01

    AWARD NUMBER: W81XWH-13-1-0494 TITLE: Tinnitus Multimodal Imaging PRINCIPAL INVESTIGATOR: Steven Wan Cheung CONTRACTING ORGANIZATION...ABOVE ADDRESS. 1. REPORT DATE December 2016 2. REPORT TYPE FINAL 3. DATES COVERED 30 October 2013 – 29 September 2016 4. TITLE AND SUBTITLE Tinnitus ...ABSTRACT Chronic subjective tinnitus is a common auditory perceptual disorder whose neural substrates remain under intense debate. This project

  13. Multimodal Emoji Prediction

    OpenAIRE

    Barbieri, Francesco; Ballesteros, Miguel; Ronzano, Francesco; Saggion, Horacio

    2018-01-01

    Emojis are small images that are commonly included in social media text messages. The combination of visual and textual content in the same message builds up a modern way of communication, that automatic systems are not used to deal with. In this paper we extend recent advances in emoji prediction by putting forward a multimodal approach that is able to predict emojis in Instagram posts. Instagram posts are composed of pictures together with texts which sometimes include emojis. We show that ...

  14. Multimodal mental imagery.

    Science.gov (United States)

    Nanay, Bence

    2017-07-17

    When I am looking at my coffee machine that makes funny noises, this is an instance of multisensory perception - I perceive this event by means of both vision and audition. But very often we only receive sensory stimulation from a multisensory event by means of one sense modality, for example, when I hear the noisy coffee machine in the next room, that is, without seeing it. The aim of this paper is to bring together empirical findings about multimodal perception and empirical findings about (visual, auditory, tactile) mental imagery and argue that on occasions like this, we have multimodal mental imagery: perceptual processing in one sense modality (here: vision) that is triggered by sensory stimulation in another sense modality (here: audition). Multimodal mental imagery is not a rare and obscure phenomenon. The vast majority of what we perceive are multisensory events: events that can be perceived in more than one sense modality - like the noisy coffee machine. And most of the time we are only acquainted with these multisensory events via a subset of the sense modalities involved - all the other aspects of these multisensory events are represented by means of multisensory mental imagery. This means that multisensory mental imagery is a crucial element of almost all instances of everyday perception. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Toward a compact fibered squeezing parametric source.

    Science.gov (United States)

    Brieussel, Alexandre; Ott, Konstantin; Joos, Maxime; Treps, Nicolas; Fabre, Claude

    2018-03-15

    In this work, we investigate three different compact fibered systems generating vacuum squeezing that involve optical cavities limited by the end surface of a fiber and by a curved mirror and containing a thin parametric crystal. These systems have the advantage to couple squeezed states directly to a fiber, allowing the user to benefit from the flexibility of fibers in the use of squeezing. Three types of fibers are investigated: standard single-mode fibers, photonic-crystal large-mode-area single-mode fibers, and short multimode fibers taped to a single-mode fiber. The observed squeezing is modest (-0.56  dB, -0.9  dB, -1  dB), but these experiments open the way for miniaturized squeezing devices that could be a very interesting advantage in scaling up quantum systems for quantum processing, opening new perspectives in the domain of integrated quantum optics.

  16. Multimodal imaging of spike propagation: a technical case report.

    Science.gov (United States)

    Tanaka, N; Grant, P E; Suzuki, N; Madsen, J R; Bergin, A M; Hämäläinen, M S; Stufflebeam, S M

    2012-06-01

    We report an 11-year-old boy with intractable epilepsy, who had cortical dysplasia in the right superior frontal gyrus. Spatiotemporal source analysis of MEG and EEG spikes demonstrated a similar time course of spike propagation from the superior to inferior frontal gyri, as observed on intracranial EEG. The tractography reconstructed from DTI showed a fiber connection between these areas. Our multimodal approach demonstrates spike propagation and a white matter tract guiding the propagation.

  17. A multimodal parallel architecture: A cognitive framework for multimodal interactions.

    Science.gov (United States)

    Cohn, Neil

    2016-01-01

    Human communication is naturally multimodal, and substantial focus has examined the semantic correspondences in speech-gesture and text-image relationships. However, visual narratives, like those in comics, provide an interesting challenge to multimodal communication because the words and/or images can guide the overall meaning, and both modalities can appear in complicated "grammatical" sequences: sentences use a syntactic structure and sequential images use a narrative structure. These dual structures create complexity beyond those typically addressed by theories of multimodality where only a single form uses combinatorial structure, and also poses challenges for models of the linguistic system that focus on single modalities. This paper outlines a broad theoretical framework for multimodal interactions by expanding on Jackendoff's (2002) parallel architecture for language. Multimodal interactions are characterized in terms of their component cognitive structures: whether a particular modality (verbal, bodily, visual) is present, whether it uses a grammatical structure (syntax, narrative), and whether it "dominates" the semantics of the overall expression. Altogether, this approach integrates multimodal interactions into an existing framework of language and cognition, and characterizes interactions between varying complexity in the verbal, bodily, and graphic domains. The resulting theoretical model presents an expanded consideration of the boundaries of the "linguistic" system and its involvement in multimodal interactions, with a framework that can benefit research on corpus analyses, experimentation, and the educational benefits of multimodality. Copyright © 2015.

  18. A catoptric lens

    International Nuclear Information System (INIS)

    Rambauske, W.R.

    1973-01-01

    The invention relates to a catoptric lens for combining energies transmitted by several sources such as lasers; said lens comprising mirrors, the reflective surfaces of which have their focuses spaced from a common axis of symmetry. By means of these reflecting surfaces, which are generated by the nutation of portions of quadratic conics about the axis of symmetry, it is possible to focus the energy emmited by several lasers at the focus of the exit-mirror reflecting surface. This can be applied to thermonuclear fusion [fr

  19. Switchable lasing in multimode microcavities

    DEFF Research Database (Denmark)

    Zhukovsky, Sergei V.; Chigrin, Dmitry N.; Lavrinenko, Andrei

    2007-01-01

    We propose the new concept of a switchable multimode microlaser. As a generic, realistic model of a multimode microresonator a system of two coupled defects in a two-dimensional photonic crystal is considered. We demonstrate theoretically that lasing of the cavity into one selected resonator mode...... in terms of the laser bistability is presented....

  20. Multimodal Analysis for Critical Thinking

    Science.gov (United States)

    O'Halloran, Kay L.; Tan, Sabine; E., Marissa K. L.

    2017-01-01

    This paper proposes a pedagogical approach for teaching and learning critical thinking through multimodal analysis--that is, "multimodal analysis for critical thinking". The approach builds on the conviction that students require competencies that move beyond traditional notions of literacy to meet the changing demands posed by media and…

  1. Simplified Multimodal Biometric Identification

    Directory of Open Access Journals (Sweden)

    Abhijit Shete

    2014-03-01

    Full Text Available Multibiometric systems are expected to be more reliable than unimodal biometric systems for personal identification due to the presence of multiple, fairly independent pieces of evidence e.g. Unique Identification Project "Aadhaar" of Government of India. In this paper, we present a novel wavelet based technique to perform fusion at the feature level and score level by considering two biometric modalities, face and fingerprint. The results indicate that the proposed technique can lead to substantial improvement in multimodal matching performance. The proposed technique is simple because of no preprocessing of raw biometric traits as well as no feature and score normalization.

  2. Multimodality, politics and ideology

    DEFF Research Database (Denmark)

    Machin, David; Van Leeuwen, T.

    2016-01-01

    , in entertainments media, software, administrative processes, children's apps, healthcare and even office furniture design. We point to the way that there have been massive shifts away from traditional state forms of politics to the rule of neoliberalism and the power of the corporation which, like the former regime...... of power, requires meanings and identities which can hold them in place. We explain the processes by which critical multimodal discourse analysis can best draw out this ideology as it is realized through different semiotics resources. © John Benjamins Publishing Company....

  3. Quadrupole magnetic lens

    International Nuclear Information System (INIS)

    Piskunov, V.A.

    1981-01-01

    The following connection of windings of electromagnet is suggested for simplification of the design of qUadrupole magnetic lens intended for use in radiotechnical and electron-optical devices. The mentioned windings are connected with each other by a bridge scheme and the variable resistors are switched in its diagonals in the lens containing four electromagnet with windings connected with two variable resistors the mobile contacts of which are connected with a direct current source. Current redistribution between left windings and right windings takes place at shift of mobile contact of variable resistor, and current redistribution between upper and low coils of electromagnets takes place at shifting mobile contact of the other variable resistor. In this case smooth and independent electron-optical misalignment of lens by two mutually perpendicular directions proceeds. Use of the given design of the lens in the oscillograph permits to use printing assembly for alignment plate and to reduce the number of connections at the expense of decreasing the number of resistors

  4. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... prescription. There is no such thing as a "one size fits all" contact lens. Lenses that are not properly fitted may scratch the eye or cause blood vessels to grow into the cornea. Even if you have perfect vision, you need to get an eye exam and a prescription ...

  5. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Ophthalmologist Patient Stories Español Eye Health / News Halloween Hazard: The Hidden Dangers of Buying Decorative Contact Lenses ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ...

  6. MISSING: BUBBLE CHAMBER LENS

    CERN Multimedia

    2001-01-01

    Would the person who borrowed the large bubble chamber lens from the Microcosm workshops on the ISR please return it. This is a much used piece from our object archives. If anybody has any information about the whereabouts of this object, please contact Emma.Sanders@cern.ch Thank you

  7. The Lens of Chemistry

    Science.gov (United States)

    Thalos, Mariam

    2013-01-01

    Chemistry possesses a distinctive theoretical lens--a distinctive set of theoretical concerns regarding the dynamics and transformations of a perplexing variety of organic and nonorganic substances--to which it must be faithful. Even if it is true that chemical facts bear a special (reductive) relationship to physical facts, nonetheless it will…

  8. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her with a corneal ... A recent article from U.S. News and World Report explains what ophthalmologists are and how they can ...

  9. bubble chamber lens

    CERN Multimedia

    Was used in a PS experiment. Before the days of electronic detectors, visual techniques were used to detect particles, using detectors such as spark chambers and bubble chambers. This plexiglass lens was used to focus the image of tracks so they could be photographed.

  10. Thermal Lens Microscope

    Science.gov (United States)

    Uchiyama, Kenji; Hibara, Akihide; Kimura, Hiroko; Sawada, Tsuguo; Kitamori, Takehiko

    2000-09-01

    We developed a novel laser microscope based on the thermal lens effect induced by a coaxial beam comprised of excitation and probe beams. The signal generation mechanism was confirmed to be an authentic thermal lens effect from the measurement of signal and phase dependences on optical configurations between the sample and the probe beam focus, and therefore, the thermal lens effect theory could be applied. Two-point spatial resolution was determined by the spot size of the excitation beam, not by the thermal diffusion length. Sensitivity was quite high, and the detection ability, evaluated using a submicron microparticle containing dye molecules, was 0.8 zmol/μm2, hence a distribution image of trace chemical species could be obtained quantitatively. In addition, analytes are not restricted to fluorescent species, therefore, the thermal lens microscope is a promising analytical microscope. A two-dimensional image of a histamine molecule distribution, which was produced in mast cells at the femtomole level in a human nasal mucous polyp, was obtained.

  11. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... an Ophthalmologist Patient Stories Español Eye Health / News Halloween Hazard: The Hidden Dangers of Buying Decorative Contact ... After One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter ...

  12. Out-of-plane integration of a multimode optical fiber for single particle/cell detection at multiple points on a microfluidic device with applications to particle/cell counting, velocimetry, size discrimination and the analysis of single cell lysate injections.

    Science.gov (United States)

    Sadeghi, Jalal; Patabadige, Damith E W; Culbertson, Anne H; Latifi, Hamid; Culbertson, Christopher T

    2016-12-20

    In this paper a single particle/cell-tracking microfluidic device that integrates an out-of-plane multimode optical fiber (OP-MMF) is reported. This OP-MMF is used to generate three excitation light-lines and three detection spots using only one excitation source and one detector. It takes advantage of an optical tunneling mode to create two excitation lines in a microfluidic channel emanating from a single fiber end. This method was used to accurately count particles/cells and perform velocity measurements and size discrimination. The velocity and size distributions of 5, 7, and 10 μm fluorescently labeled polystyrene beads were determined using the OP-MMF. Additionally, this method was used to analyze cell lysates with the third excitation line in the separation channel. The OP-MMF setup accurately detected an intact cell twice ∼2 mm prior to lysis, determined its velocity, and detected the injected cell lysate 3 mm downstream of the injection point in the separation channel. Using this setup, the velocity of cells entering the lysis intersection and the absolute migration times of fluorescently labeled analytes injected into the separation channel were determined in an automated fashion. This method enabled us to determine a lysing/injection efficiency coefficient (K) using signals from the injected lysate signal and from the intact cell before lysing. K provided a reliable measurement of the amount of cell lysate that was injected into the separation channel. The approach reported here could be used in the future to track particles, cells or droplets in a variety of existing microfluidic devices without the need for multiplexed masks, layers, bulky optical elements or complex optical designs.

  13. Spatial distribution of glycerophospholipids in the ocular lens.

    Directory of Open Access Journals (Sweden)

    Jaroslav Pól

    Full Text Available Knowledge of the spatial distribution of lipids in the intraocular lens is important for understanding the physiology and biochemistry of this unique tissue and for gaining a better insight into the mechanisms underlying diseases of the lens. Following our previous study showing the spatial distribution of sphingolipids in the porcine lens, the current study used ultra performance liquid chromatography quadrupole time-of-flight mass spectrometry (UPLC-QTOFMS to provide the whole lipidome of porcine lens and these studies were supplemented by matrix-assisted laser desorption ionization mass spectrometry imaging (MALDI MSI of the lens using ultra-high resolution Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS to determine the spatial distribution of glycerophospholipids. Altogether 172 lipid species were identified with high confidence and their concentration was determined. Sphingomyelins, phosphatidylcholines, and phosphatidylethanolamines were the most abundant lipid classes. We then determined the spatial and concentration-dependent distributions of 20 phosphatidylcholines, 6 phosphatidylethanolamines, and 4 phosphatidic acids. Based on the planar molecular images of the lipids, we report the organization of fiber cell membranes within the ocular lens and suggest roles for these lipids in normal and diseased lenses.

  14. Clinical survey of lens care in contact lens patients.

    Science.gov (United States)

    Ky, W; Scherick, K; Stenson, S

    1998-10-01

    Overall, contact lenses provide a safe and effective modality for vision correction. However, problems do occasionally arise. Up to 80% of contact lens complications can be traced to poor patient compliance with recommended lens care guidelines. We conducted a survey to evaluate the level of patient compliance in specific areas of lens care and maintenance and to assess patient knowledge of basic contact lens information. Patients were asked to complete an anonymous 15 question survey that focused on lens care--specifically the use of contact lens cleaners, methods of disinfection, enzyme treatments, use of rewetting drops, and the frequency of follow-up exams. In addition, the survey included six true/false questions relating to contact lens care and safety. There were a total of 103 participants in the study. Approximately 24% of patients stated they never cleaned their lenses prior to disinfection, and 5% used saline solutions as their primary mode of disinfection. A sizable portion of those surveyed (43% of soft lens wearers and 71% of rigid gas permeable lens wearers) either never used enzyme cleaners or used them less than once a month. Seventy percent of patients either never used rewetting drops or used them less than once a day. Twenty-nine percent of patients consulted their eye care professionals every 2 years and 6% less often than every two years. Six questions assessed patient knowledge of contact lens care safety. Of a possible six out of six correct answers, the mean number of correct responses was 3.74. A sizable proportion of contact lens wearers do not adequately adhere to recommended contact lens care, and many have an inadequate understanding of contact lens care guidelines. Therefore, it is important that practitioners place more emphasis on patient education at the time of initial contact lens fitting and reinforce such instruction during follow-up visits.

  15. Using multiple metaphors and multimodalities as a semiotic resource when teaching year 2 students computational strategies

    Science.gov (United States)

    Mildenhall, Paula; Sherriff, Barbara

    2017-06-01

    Recent research indicates that using multimodal learning experiences can be effective in teaching mathematics. Using a social semiotic lens within a participationist framework, this paper reports on a professional learning collaboration with a primary school teacher designed to explore the use of metaphors and modalities in mathematics instruction. This video case study was conducted in a year 2 classroom over two terms, with the focus on building children's understanding of computational strategies. The findings revealed that the teacher was able to successfully plan both multimodal and multiple metaphor learning experiences that acted as semiotic resources to support the children's understanding of abstract mathematics. The study also led to implications for teaching when using multiple metaphors and multimodalities.

  16. A fiber optic sensor for nerve agent

    Science.gov (United States)

    Cordero, Steven R.; Mukamal, Harold; Low, Aaron; Locke, Edward P.; Lieberman, Robert A.

    2006-10-01

    We report advances made on the development of a fiber optic nerve agent sensor having its entire length as the sensing element. The optical fiber is multimode, and consists of a fused-silica core and a nerve agent sensitive cladding. Upon exposure to sarin gas, the cladding changes color, resulting in an alteration of the light intensity throughput. The fiber is mass produced using a conventional fiber optic draw tower. This technology could replace, or be used with, a collection of point-detectors to protect personnel, buildings and perimeters from dangerous chemical attacks.

  17. Development of a novel mixed hemimicelles dispersive micro solid phase extraction using 1-hexadecyl-3-methylimidazolium bromide coated magnetic graphene for the separation and preconcentration of fluoxetine in different matrices before its determination by fiber optic linear array spectrophotometry and mode-mismatched thermal lens spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kazemi, Elahe; Haji Shabani, Ali Mohammad [Department of Chemistry, Yazd University, Safaieh, 89195-741, Yazd (Iran, Islamic Republic of); Dadfarnia, Shayessteh, E-mail: sdadfarnia@yazd.ac.ir [Department of Chemistry, Yazd University, Safaieh, 89195-741, Yazd (Iran, Islamic Republic of); Abbasi, Amir [Department of Physics, Yazd University, Safaieh, 89195-741, Yazd (Iran, Islamic Republic of); Rashidian Vaziri, Mohammad Reza [Laser and Optics Research School, 14155-1339, Tehran (Iran, Islamic Republic of); Behjat, Abbas [Department of Physics, Yazd University, Safaieh, 89195-741, Yazd (Iran, Islamic Republic of)

    2016-01-28

    This study aims at developing a novel, sensitive, fast, simple and convenient method for separation and preconcentration of trace amounts of fluoxetine before its spectrophotometric determination. The method is based on combination of magnetic mixed hemimicelles solid phase extraction and dispersive micro solid phase extraction using 1-hexadecyl-3-methylimidazolium bromide coated magnetic graphene as a sorbent. The magnetic graphene was synthesized by a simple coprecipitation method and characterized by X-ray diffraction (XRD), Fourier transform infrared (FT-IR) spectroscopy and scanning electron microscopy (SEM). The retained analyte was eluted using a 100 μL mixture of methanol/acetic acid (9:1) and converted into fluoxetine-β-cyclodextrin inclusion complex. The analyte was then quantified by fiber optic linear array spectrophotometry as well as mode-mismatched thermal lens spectroscopy (TLS). The factors affecting the separation, preconcentration and determination of fluoxetine were investigated and optimized. With a 50 mL sample and under optimized conditions using the spectrophotometry technique, the method exhibited a linear dynamic range of 0.4–60.0 μg L{sup −1}, a detection limit of 0.21 μg L{sup −1}, an enrichment factor of 167, and a relative standard deviation of 2.1% and 3.8% (n = 6) at 60 μg L{sup −1} level of fluoxetine for intra- and inter-day analyses, respectively. However, with thermal lens spectrometry and a sample volume of 10 mL, the method exhibited a linear dynamic range of 0.05–300 μg L{sup −1}, a detection limit of 0.016 μg L{sup −1} and a relative standard deviation of 3.8% and 5.6% (n = 6) at 60 μg L{sup −1} level of fluoxetine for intra- and inter-day analyses, respectively. The method was successfully applied to determine fluoxetine in pharmaceutical formulation, human urine and environmental water samples. - Graphical abstract: A novel, sensitive, fast, simple and convenient mixed hemimicelles

  18. Development of a novel mixed hemimicelles dispersive micro solid phase extraction using 1-hexadecyl-3-methylimidazolium bromide coated magnetic graphene for the separation and preconcentration of fluoxetine in different matrices before its determination by fiber optic linear array spectrophotometry and mode-mismatched thermal lens spectroscopy

    International Nuclear Information System (INIS)

    Kazemi, Elahe; Haji Shabani, Ali Mohammad; Dadfarnia, Shayessteh; Abbasi, Amir; Rashidian Vaziri, Mohammad Reza; Behjat, Abbas

    2016-01-01

    This study aims at developing a novel, sensitive, fast, simple and convenient method for separation and preconcentration of trace amounts of fluoxetine before its spectrophotometric determination. The method is based on combination of magnetic mixed hemimicelles solid phase extraction and dispersive micro solid phase extraction using 1-hexadecyl-3-methylimidazolium bromide coated magnetic graphene as a sorbent. The magnetic graphene was synthesized by a simple coprecipitation method and characterized by X-ray diffraction (XRD), Fourier transform infrared (FT-IR) spectroscopy and scanning electron microscopy (SEM). The retained analyte was eluted using a 100 μL mixture of methanol/acetic acid (9:1) and converted into fluoxetine-β-cyclodextrin inclusion complex. The analyte was then quantified by fiber optic linear array spectrophotometry as well as mode-mismatched thermal lens spectroscopy (TLS). The factors affecting the separation, preconcentration and determination of fluoxetine were investigated and optimized. With a 50 mL sample and under optimized conditions using the spectrophotometry technique, the method exhibited a linear dynamic range of 0.4–60.0 μg L −1 , a detection limit of 0.21 μg L −1 , an enrichment factor of 167, and a relative standard deviation of 2.1% and 3.8% (n = 6) at 60 μg L −1 level of fluoxetine for intra- and inter-day analyses, respectively. However, with thermal lens spectrometry and a sample volume of 10 mL, the method exhibited a linear dynamic range of 0.05–300 μg L −1 , a detection limit of 0.016 μg L −1 and a relative standard deviation of 3.8% and 5.6% (n = 6) at 60 μg L −1 level of fluoxetine for intra- and inter-day analyses, respectively. The method was successfully applied to determine fluoxetine in pharmaceutical formulation, human urine and environmental water samples. - Graphical abstract: A novel, sensitive, fast, simple and convenient mixed hemimicelles dispersive micro solid

  19. [Correct contact lens hygiene].

    Science.gov (United States)

    Blümle, S; Kaercher, T; Khaireddin, R

    2013-06-01

    Although contact lenses have long been established in ophthalmology, practical aspects of handling contact lenses is becoming increasingly less important in the clinical training as specialist for ophthalmology. Simultaneously, for many reasons injuries due to wearing contact lenses are increasing. In order to correct this discrepancy, information on contact lenses and practical experience with them must be substantially increased from a medical perspective. This review article deals with the most important aspects for prevention of complications, i.e. contact lens hygiene.

  20. Multimodal hyperspectral optical microscopy

    Science.gov (United States)

    Novikova, Irina V.; Smallwood, Chuck R.; Gong, Yu; Hu, Dehong; Hendricks, Leif; Evans, James E.; Bhattarai, Ashish; Hess, Wayne P.; El-Khoury, Patrick Z.

    2017-11-01

    We describe a unique approach to hyperspectral optical microscopy, herein achieved by coupling a hyperspectral imager to various optical microscopes. Hyperspectral fluorescence micrographs of isolated fluorescent beads are first employed to ensure spectral calibration of our detector and to gauge the attainable spatial resolution of our measurements. Different science applications of our instrument are then described. Spatially over-sampled absorption spectroscopy of a single lipid (18:1 Liss Rhod PE) layer reveals that optical densities on the order of 10-3 can be resolved by spatially averaging the recorded optical signatures. This is followed by three applications in the general areas of plasmonics and bioimaging. Notably, we deploy hyperspectral absorption microscopy to identify and image pigments within a simple biological system, namely, a single live Tisochrysis lutea cell. Overall, this work paves the way for multimodal spectral imaging measurements spanning the realms of several scientific disciplines.

  1. [Multimodal serotonergic antidepressants].

    Science.gov (United States)

    Danilov, D S

    Based on the original literature, the author for the first time describes a history of selective serotonergic antidepressants simultaneously inhibiting the serotonin reuptake and directly interacting with serotonin receptors. A history of creation and introduction of their main representatives is presented. A history of investigation of their neurochemical activity is analyzed in details. The history of the evolution of their classifications is systemized. The data presented suggest the rationale for unifying all selective serotonergic antidepressants, simultaneously inhibiting the serotonin reuptake and directly interacting with serotonin receptors (trazodone, etoperidone, nefazodone, vilazodone, vortioxetine), in one group of 'multimodal serotonergic antidepressants'. The expediency to include this group in the modern neurochemical classification of nootropic drugs is substantiated.

  2. GFOC Project results: High Temperature / High Pressure, Hydrogen Tolerant Optical Fiber

    Energy Technology Data Exchange (ETDEWEB)

    E. Burov; A. Pastouret; E. Aldea; B. Overton; F. Gooijer; A. Bergonzo

    2012-02-12

    Tests results are given for exposure of multimode optical fiber to high temperatures (300 deg. C) and high partial pressure (15 bar) hydrogen. These results demonstrate that fluorine down doped optical fibers are much more hydrogen tolerant than traditional germanium doped multimode optical fibers. Also demonstrated is the similar hydrogen tolerance of carbon coated and non-carbon coated fibers. Model for reversible H2 impact in fiber versus T{sup o}C and H2 pressure is given. These results have significant impact for the longevity of use for distributed temperature sensing applications in harsh environments such as geothermal wells.

  3. Tunable Optical Filter Based on Mechanically Induced Cascaded Long Period Optical Fiber Grating

    Directory of Open Access Journals (Sweden)

    Sunita P. Ugale

    2013-01-01

    Full Text Available We have proposed and demonstrated experimentally a novel and simple tunable optical filter based on mechanically induced and cascaded long period optical fiber gratings. In this filter variable FWHM and center wavelength is provided by cascading long period and ultralong period optical fiber gratings with different periods in a novel fiber structure. We report here for the first time to our knowledge the characterization of mechanically induced long period fiber gratings with periods up to several millimeters in novel multimode-single-mode-multimode fiber structure. We have obtained maximum loss peak of around 20 dB.

  4. An integral-field spectroscopic strong lens survey

    Energy Technology Data Exchange (ETDEWEB)

    Bolton, Adam S [Harvard-Smithsonian Center for Astrophysics, 60 Garden St. MS-20, Cambridge, MA 02138 (United States); Burles, Scott [Department of Physics and Kavli Institute, Massachusetts Institute of Technology, 77 Massachusetts Ave., Cambridge, MA 02139 (United States)

    2007-12-15

    We present the observational results of a survey for strong gravitational lens systems consisting of extended emission-line galaxies lensed by intervening early-type galaxies, conducted using integral field units (IFUs) of the Magellan IMACS and Gemini GMOS-N spectrographs. These data are highly valuable for corroborating the lensing interpretation of Hubble Space Telescope imaging data. We show that in many cases, ground-based IFU spectroscopy is in fact competitive with space-based imaging for the measurement of the mass model parameters of the lensing galaxy. We demonstrate a novel technique of three-dimensional gravitational lens modeling for a single lens system with a resolved lensed rotation curve. We also describe the details of our custom IFU data analysis software, which performs optimal multi-fiber extraction, relative and absolute wavelength calibration to a few hundredths of a pixel RMS and nearly Poisson-limited sky subtraction.

  5. No turnover in lens lipids for the entire human lifespan.

    Science.gov (United States)

    Hughes, Jessica R; Levchenko, Vladimir A; Blanksby, Stephen J; Mitchell, Todd W; Williams, Alan; Truscott, Roger J W

    2015-03-11

    Lipids are critical to cellular function and it is generally accepted that lipid turnover is rapid and dysregulation in turnover results in disease (Dawidowicz 1987; Phillips et al., 2009; Liu et al., 2013). In this study, we present an intriguing counter-example by demonstrating that in the center of the human ocular lens, there is no lipid turnover in fiber cells during the entire human lifespan. This discovery, combined with prior demonstration of pronounced changes in the lens lipid composition over a lifetime (Hughes et al., 2012), suggests that some lipid classes break down in the body over several decades, whereas others are stable. Such substantial changes in lens cell membranes may play a role in the genesis of age-related eye disorders. Whether long-lived lipids are present in other tissues is not yet known, but this may prove to be important in understanding the development of age-related diseases.

  6. An integral-field spectroscopic strong lens survey

    International Nuclear Information System (INIS)

    Bolton, Adam S; Burles, Scott

    2007-01-01

    We present the observational results of a survey for strong gravitational lens systems consisting of extended emission-line galaxies lensed by intervening early-type galaxies, conducted using integral field units (IFUs) of the Magellan IMACS and Gemini GMOS-N spectrographs. These data are highly valuable for corroborating the lensing interpretation of Hubble Space Telescope imaging data. We show that in many cases, ground-based IFU spectroscopy is in fact competitive with space-based imaging for the measurement of the mass model parameters of the lensing galaxy. We demonstrate a novel technique of three-dimensional gravitational lens modeling for a single lens system with a resolved lensed rotation curve. We also describe the details of our custom IFU data analysis software, which performs optimal multi-fiber extraction, relative and absolute wavelength calibration to a few hundredths of a pixel RMS and nearly Poisson-limited sky subtraction

  7. Nanofilms on a hollow core fiber

    Science.gov (United States)

    Matias, Ignacio R.; Bravo, Javier; Arregui, Francisco J.; Corres, Jesús M.

    2006-05-01

    We experimentally study the behavior of one multimode fiber-hollow core fiber-multimode fiber structure when nanofilms are deposited on it with the aim of developing practical evanescent field-based devices, such as sensors, filters, etc. The electrostatic self-assembly (ESA) method is used as the deposition technique and the chosen polymers are PDDA and Poly R-478 because of their well-known optical properties and their potential application as humidity sensors. Three different types of hollow core, fibers are used for the fabrication of the devices and at two different wavelengths. An oscillatory-decreasing transmitted optical power is obtained as the thickness of the nanofilms is increased.

  8. Radio-over-Fiber Transmission Using Vortex Modes

    DEFF Research Database (Denmark)

    Tatarczak, Anna; Lu, Xiaofeng; Rommel, Simon

    2015-01-01

    This paper demonstrates experimentally the distribution of radio-over-fiber (RoF) signals using orbital angular momentum (OAM) of light over standard OM4 multimode fiber (MMF) at 850 nm wavelength. Five independent OAM modes are used to convey RoF signals in the microwave regime showing robust pe...

  9. Relational Multimodal Freight Database Webinar

    Science.gov (United States)

    2012-02-01

    The relational Multimodal Freight Database (MFD) was developed as part of Texas Department : of Transportation (TxDOT) Research Project 0-6297 entitled Freight Planning Factors Impacting : Texas Commodity Flows, conducted by the Center for Transporta...

  10. Prolonging contact lens wear and making contact lens wear safer.

    Science.gov (United States)

    Foulks, Gary N

    2006-02-01

    To summarize the present status of safety and efficacy of contact lens wear. Literature review. Ovid Medline searches were performed on records from 1966 through 2005 using keywords: keratitis, contact lens complications, extended-wear contact lenses, and silicone-hydrogel contact lenses. Patients desire comfort, clarity of vision, and prolonged contact lens wear when contact lenses are used to correct refractive error. Practitioners desire patient satisfaction but also require maintenance of the integrity of the eye and no complications that jeopardize vision or health of the eye. Improvements in the oxygen permeability of the contact lens materials, design of the contact lens and its surface, and solutions for the maintenance of the lens have reduced but not eliminated the risks of infection, inflammation, and conjunctival papillary reaction associated with contact lens wear. The lessons of past and recent history suggest that patient education and practitioner participation in the management of contact lens wear continue to be critical factors for patient satisfaction and safety in the extended wear of contact lenses. The availability of highly oxygen permeable contact lenses has increased the tolerance and safety of extended contact lens wear, but patient instruction and education in proper use and care of lenses is required and caution is advised.

  11. Ball lens based lensed patch cord probes for optical coherence tomography in the field of dentistry

    Science.gov (United States)

    Eom, J. B.; Kim, Y.; Lee, S. J.; Min, E. J.; Park, S. J.; Lee, B. H.

    2012-10-01

    A lensed patch cord probe has been made with a ball lens packaged in a metal cylinder. By simply placing a ball lens directly in front of a fiber patch cord, a compact and potentially disposable sampling probe for optical coherence tomography (OCT) could be implemented. To achieve a sufficiently long working distance and a good transverse resolution simultaneously, the proper ball lens diameter and the distance between the ball lens and the fiber patch cord were investigated. Experimentally, a working distance of up to 5.2 mm, 3 dB bandwidth of 2 mm, and transverse resolution of 16 μm were achieved. With the patch cord probe, a common path swept source OCT system was implemented and used to demonstrate the feasibility as the dedicated probe for dentistry.

  12. Learning human multimodal dialogue strategies

    OpenAIRE

    Rieser, V.; Lemon, O.

    2010-01-01

    We investigate the use of different machine learning methods in combination with feature selection techniques to explore human multimodal dialogue strategies and the use of those strategies for automated dialogue systems. We learn policies from data collected in a Wizard-of-Oz study where different human 'wizards' decide whether to ask a clarification request in a multimodal manner or else to use speech alone. We first describe the data collection, the coding scheme and annotated corpus, and ...

  13. Robustness of multimodal processes itineraries

    DEFF Research Database (Denmark)

    Bocewicz, G.; Banaszak, Z.; Nielsen, Izabela Ewa

    2013-01-01

    This paper concerns multimodal transport systems (MTS) represented by a supernetworks in which several unimodal networks are connected by transfer links and focuses on the scheduling problems encountered in these systems. Assuming unimodal networks are modeled as cyclic lines, i.e. the routes det...... of multimodal processes driven itinerary planning problem is our main contribution. Illustrative examples providing alternative itineraries in some cases of MTS malfunction are presented....

  14. Fiber cavities with integrated mode matching optics.

    Science.gov (United States)

    Gulati, Gurpreet Kaur; Takahashi, Hiroki; Podoliak, Nina; Horak, Peter; Keller, Matthias

    2017-07-17

    In fiber based Fabry-Pérot Cavities (FFPCs), limited spatial mode matching between the cavity mode and input/output modes has been the main hindrance for many applications. We have demonstrated a versatile mode matching method for FFPCs. Our novel design employs an assembly of a graded-index and large core multimode fiber directly spliced to a single mode fiber. This all-fiber assembly transforms the propagating mode of the single mode fiber to match with the mode of a FFPC. As a result, we have measured a mode matching of 90% for a cavity length of ~400 μm. This is a significant improvement compared to conventional FFPCs coupled with just a single mode fiber, especially at long cavity lengths. Adjusting the parameters of the assembly, the fundamental cavity mode can be matched with the mode of almost any single mode fiber, making this approach highly versatile and integrable.

  15. Yeast viability and concentration analysis using lens-free computational microscopy and machine learning

    Science.gov (United States)

    Feizi, Alborz; Zhang, Yibo; Greenbaum, Alon; Guziak, Alex; Luong, Michelle; Chan, Raymond Yan Lok; Berg, Brandon; Ozkan, Haydar; Luo, Wei; Wu, Michael; Wu, Yichen; Ozcan, Aydogan

    2017-03-01

    Research laboratories and the industry rely on yeast viability and concentration measurements to adjust fermentation parameters such as pH, temperature, and pressure. Beer-brewing processes as well as biofuel production can especially utilize a cost-effective and portable way of obtaining data on cell viability and concentration. However, current methods of analysis are relatively costly and tedious. Here, we demonstrate a rapid, portable, and cost-effective platform for imaging and measuring viability and concentration of yeast cells. Our platform features a lens-free microscope that weighs 70 g and has dimensions of 12 × 4 × 4 cm. A partially-coherent illumination source (a light-emitting-diode), a band-pass optical filter, and a multimode optical fiber are used to illuminate the sample. The yeast sample is directly placed on a complementary metal-oxide semiconductor (CMOS) image sensor chip, which captures an in-line hologram of the sample over a large field-of-view of >20 mm2. The hologram is transferred to a touch-screen interface, where a trained Support Vector Machine model classifies yeast cells stained with methylene blue as live or dead and measures cell viability as well as concentration. We tested the accuracy of our platform against manual counting of live and dead cells using fluorescent exclusion staining and a bench-top fluorescence microscope. Our regression analysis showed no significant difference between the two methods within a concentration range of 1.4 × 105 to 1.4 × 106 cells/mL. This compact and cost-effective yeast analysis platform will enable automatic quantification of yeast viability and concentration in field settings and resource-limited environments.

  16. Multimodal label-free microscopy

    Directory of Open Access Journals (Sweden)

    Nicolas Pavillon

    2014-09-01

    Full Text Available This paper reviews the different multimodal applications based on a large extent of label-free imaging modalities, ranging from linear to nonlinear optics, while also including spectroscopic measurements. We put specific emphasis on multimodal measurements going across the usual boundaries between imaging modalities, whereas most multimodal platforms combine techniques based on similar light interactions or similar hardware implementations. In this review, we limit the scope to focus on applications for biology such as live cells or tissues, since by their nature of being alive or fragile, we are often not free to take liberties with the image acquisition times and are forced to gather the maximum amount of information possible at one time. For such samples, imaging by a given label-free method usually presents a challenge in obtaining sufficient optical signal or is limited in terms of the types of observable targets. Multimodal imaging is then particularly attractive for these samples in order to maximize the amount of measured information. While multimodal imaging is always useful in the sense of acquiring additional information from additional modes, at times it is possible to attain information that could not be discovered using any single mode alone, which is the essence of the progress that is possible using a multimodal approach.

  17. Optical fiber sensors measurement system and special fibers improvement

    Science.gov (United States)

    Jelinek, Michal; Hrabina, Jan; Hola, Miroslava; Hucl, Vaclav; Cizek, Martin; Rerucha, Simon; Lazar, Josef; Mikel, Bretislav

    2017-06-01

    We present method for the improvement of the measurement accuracy in the optical frequency spectra measurements based on tunable optical filters. The optical filter was used during the design and realization of the measurement system for the inspection of the fiber Bragg gratings. The system incorporates a reference block for the compensation of environmental influences, an interferometric verification subsystem and a PC - based control software implemented in LabView. The preliminary experimental verification of the measurement principle and the measurement system functionality were carried out on a testing rig with a specially prepared concrete console in the UJV Řež. The presented system is the laboratory version of the special nuclear power plant containment shape deformation measurement system which was installed in the power plant Temelin during last year. On the base of this research we started with preparation other optical fiber sensors to nuclear power plants measurement. These sensors will be based on the microstructured and polarization maintaining optical fibers. We started with development of new methods and techniques of the splicing and shaping optical fibers. We are able to made optical tapers from ultra-short called adiabatic with length around 400 um up to long tapers with length up to 6 millimeters. We developed new techniques of splicing standard Single Mode (SM) and Multimode (MM) optical fibers and splicing of optical fibers with different diameters in the wavelength range from 532 to 1550 nm. Together with development these techniques we prepared other techniques to splicing and shaping special optical fibers like as Polarization-Maintaining (PM) or hollow core Photonic Crystal Fiber (PCF) and theirs cross splicing methods with focus to minimalize backreflection and attenuation. The splicing special optical fibers especially PCF fibers with standard telecommunication and other SM fibers can be done by our developed techniques. Adjustment

  18. Highly sensitive miniature fluidic flowmeter based on an FBG heated by Co2+-doped fiber

    NARCIS (Netherlands)

    Liu, Z.; Htein, L.; Cheng, L.K.; Martina, Q.; Jansen, R.; Tam, H.Y.

    2017-01-01

    In this paper, we present a miniature fluidic flow sensor based on a short fiber Bragg grating inscribed in a single mode fiber and heated by Co2+-doped multimode fibers. The proposed flow sensor was employed to measure the flow rates of oil and water, showing good sensitivity of 0.339 nm/(m/s) and

  19. All-fiber 7x1 signal combiner for incoherent laser beam combining

    DEFF Research Database (Denmark)

    Noordegraaf, Danny; Maack, Martin D.; Skovgaard, Peter M. W.

    2011-01-01

    We demonstrate an all-fiber 7x1 signal combiner for incoherent laser beam combining. This is a potential key component for reaching several kW of stabile laser output power. The combiner couples the output from 7 single-mode (SM) fiber lasers into a single multi-mode (MM) fiber. The input signal ...

  20. Dietary Fiber

    Science.gov (United States)

    ... label as soluble fiber or insoluble fiber. Both types have important health benefits. Good sources of dietary fiber include Whole grains Nuts and seeds Fruit and vegetables Dietary fiber adds bulk to ...

  1. New development in optical fibers for data center applications

    Science.gov (United States)

    Sun, Yi; Shubochkin, Roman; Zhu, Benyuan

    2015-01-01

    VCSEL-multimode optical fiber based links is the most successful optical technology in Data Centers. Laser-optimized multimode optical fibers, OM3 and OM4, have been the primary choice of physical media for 10 G serial, 4 x 10 G parallel, 10 x 10 G parallel, and 4 x 25 G parallel optical solutions in IEEE 802.3 standards. As the transition of high-end servers from 10 Gb/s to 40 Gb/s is driving the aggregation of speeds to 40 Gb/s now, and to 100 Gb/s and 400 Gb/s in near future, industry experts are coming together in IEEE 802.3bs 400 Gb/s study group and preliminary discussion of Terabit transmission for datacom applications has also been commenced. To meet the requirement of speed, capacity, density, power consumption and cost for next generation datacom applications, optical fiber design concepts beyond the standard OM3 and OM4 MMFs have a revived research and developmental interest, for example, wide band multimode optical fiber using multiple dopants for coarse wavelength division multiplexing; multicore multimode optical fiber using plural multimode cores in a single fiber strand to improve spatial density; and perhaps 50 Gb/s per lane and few mode fiber in spatial division multiplexing for ultimate capacity increase in far future. This talk reviews the multitude of fiber optic media being developed in the industry to address the upcoming challenges of datacom growth. We conclude that multimode transmission using low cost VCSEL technology will continue to be a viable solution for datacom applications.

  2. Fiber webs

    Science.gov (United States)

    Roger M. Rowell; James S. Han; Von L. Byrd

    2005-01-01

    Wood fibers can be used to produce a wide variety of low-density three-dimensional webs, mats, and fiber-molded products. Short wood fibers blended with long fibers can be formed into flexible fiber mats, which can be made by physical entanglement, nonwoven needling, or thermoplastic fiber melt matrix technologies. The most common types of flexible mats are carded, air...

  3. Pigment dispersion syndrome associated with spontaneous subluxation of crystalline lens

    Directory of Open Access Journals (Sweden)

    Vikas Veerwal

    2017-01-01

    Full Text Available Pigment dispersion syndrome (PDS is an ocular condition characterized by a dispersion of iris pigment throughout the eye. This pigment is deposited in a characteristic manner on the corneal endothelium as Krukenberg's spindle, anterior surface of the iris, in the trabecular meshwork, on the lens and zonule and occasionally on the anterior hyaloid face. Even with deposition of pigment on zonular fibers, no zonular weakness, or zonular dehiscence has been reported in these cases. We report a unique case of PDS with bilateral spontaneous subluxation of crystalline lens. With characteristic findings of pigment distribution in both his eyes, the patient had concave iris configuration with heavily pigmented trabecular meshwork confirming the diagnosis of PDS. The patient had bilateral 180° temporal subluxation of crystalline lens in both his eyes. The usual cause of lens subluxation such as Marfan's Syndrome and Ehler's Danlos Syndrome was ruled out. The patient underwent right eye followed by left eye intracapsular cataract extraction with ab-interno technique with postoperative best-corrected visual acuity (BCVA of 6/9 in both eyes. Spontaneous subluxation of crystalline lens in isolated PDS is not known to occur and has been reported by means of this case. We recommend a thorough assessment of zonular status in all cases of PDS.

  4. Cholesterol Bilayer Domains in the Eye Lens Health: A Review.

    Science.gov (United States)

    Widomska, Justyna; Subczynski, Witold K; Mainali, Laxman; Raguz, Marija

    2017-12-01

    The most unique biochemical characteristic of the eye lens fiber cell plasma membrane is its extremely high cholesterol content, the need for which is still unclear. It is evident, however, that the disturbance of Chol homeostasis may result in damages associated with cataracts. Electron paramagnetic resonance methods allow discrimination of two types of lipid domains in model membranes overloaded with Chol, namely, phospholipid-cholesterol domains and pure Chol bilayer domains. These domains are also detected in human lens lipid membranes prepared from the total lipids extracted from lens cortices and nuclei of donors from different age groups. Independent of the age-related changes in phospholipid composition, the physical properties of phospholipid-Chol domains remain the same for all age groups and are practically identical for cortical and nuclear membranes. The presence of Chol bilayer domains in these membranes provides a buffering capacity for cholesterol concentration in the surrounding phospholipid-Chol domains, keeping it at a constant saturating level and thus keeping the physical properties of the membrane consistent with and independent of changes in phospholipid composition. It seems that the presence of Chol bilayer domains plays an integral role in the regulation of cholesterol-dependent processes in fiber cell plasm membranes and in the maintenance of fiber cell membrane homeostasis.

  5. Super- and Anti-Principal-Modes in Multimode Waveguides

    Science.gov (United States)

    Ambichl, Philipp; Xiong, Wen; Bromberg, Yaron; Redding, Brandon; Cao, Hui; Rotter, Stefan

    2017-10-01

    We introduce special states for light in multimode waveguides featuring strongly enhanced or reduced spectral correlations in the presence of strong mode coupling. Based on the experimentally measured multispectral transmission matrix of a multimode fiber, we generate a set of states that outperform the established "principal modes" in terms of the spectral stability of their output spatial field profiles. Inverting this concept also allows us to create states with a minimal spectral correlation width, whose output profiles are considerably more sensitive to a frequency change than typical input wave fronts. The resulting "super-principal-modes" and "anti-principal-modes" are made orthogonal to each other even in the presence of mode-dependent loss. By decomposing them in the principal-mode basis, we show that the super-principal-modes are formed via interference of principal modes with close delay times, whereas the anti-principal-modes are a superposition of principal modes with the most-different delay times available in the fiber. Such novel states are expected to have broad applications in fiber communication, imaging, and spectroscopy.

  6. Phasing a Dual Optical Path System Using an Optical Fiber as a Phase Conjugate Mirror

    National Research Council Canada - National Science Library

    Willis, Shawn

    2003-01-01

    Phase conjugation properties of stimulated Brillouin scattering (SBS) in a short multimode fiber have been investigated with an eye towards its application for a multi-channel double pass master oscillator power amplifier (MOPA) system...

  7. Compliance among soft contact lens wearers.

    OpenAIRE

    Kuzman, Tomislav; Barišić Kutija, Marija; Masnec, Sanja; Jandroković, Sonja; Mrazovac, Danijela; Jurišić, Darija; Škegro, Ivan; Kalauz, Miro; Kordić, Rajko

    2014-01-01

    Contact lens compliance is proven to be crucial for preventing lens wear-related complications because of the interdependence of the steps in lens care regime and their influence on lens system microbial contamination. Awareness of the patients' lens handling compliance as well as correct recognition of non-compliant behaviours is the basis for creating more targeted strategies for patient education. The aim of this study was to investigate compliance among soft contact lens (SCL) wearers in ...

  8. Panoramic lens applications revisited

    Science.gov (United States)

    Thibault, Simon

    2008-04-01

    During the last few years, innovative optical design strategies to generate and control image mapping have been successful in producing high-resolution digital imagers and projectors. This new generation of panoramic lenses includes catadioptric panoramic lenses, panoramic annular lenses, visible/IR fisheye lenses, anamorphic wide-angle attachments, and visible/IR panomorph lenses. Given that a wide-angle lens images a large field of view on a limited number of pixels, a systematic pixel-to-angle mapping will help the efficient use of each pixel in the field of view. In this paper, we present several modern applications of these modern types of hemispheric lenses. Recently, surveillance and security applications have been proposed and published in Security and Defence symposium. However, modern hemispheric lens can be used in many other fields. A panoramic imaging sensor contributes most to the perception of the world. Panoramic lenses are now ready to be deployed in many optical solutions. Covered applications include, but are not limited to medical imaging (endoscope, rigiscope, fiberscope...), remote sensing (pipe inspection, crime scene investigation, archeology...), multimedia (hemispheric projector, panoramic image...). Modern panoramic technologies allow simple and efficient digital image processing and the use of standard image analysis features (motion estimation, segmentation, object tracking, pattern recognition) in the complete 360° hemispheric area.

  9. Effects of dietary deficiency of selective amino acids on the function of the cornea and lens in rats.

    Science.gov (United States)

    Wegener, A; Golubnitschaja, O; Breipohl, W; Schild, H H; Vrensen, G F J M

    2002-01-01

    Effects of dietary deficiencies of tryptophan and methionin on the transparency of cornea and lens were investigated in young rats (Brown-Norway, BN; Sprague-Dawley, SD) over 3 months. Transparency of the cornea and lens were evaluated in weekly intervals using a photo-slitlamp microscope. After sacrifice and lens fresh weight determination the lenses were prepared for histopathology. Methionin deficiency had no effect on the parameters investigated. Tryptophan deficiency caused severe loss of body weight in both strains, with additional loss of hair in SD rats. These developed corneal neovascularisations and cataracts. BN rats showed an enhanced zone of discontinuity in the lens. Diet intermission arrested the pathological processes in the eye which restarted when feeding the diet again. This observation is supported by lens fresh weight data. DNA staining evidenced that tryptophan deficiency arrested lens fiber maturation in both strains but stimulated corneal neovascularisation only in SD rats.

  10. Fiber transport of spatially entangled photons

    Science.gov (United States)

    Löffler, W.; Eliel, E. R.; Woerdman, J. P.; Euser, T. G.; Scharrer, M.; Russell, P.

    2012-03-01

    High-dimensional entangled photons pairs are interesting for quantum information and cryptography: Compared to the well-known 2D polarization case, the stronger non-local quantum correlations could improve noise resistance or security, and the larger amount of information per photon increases the available bandwidth. One implementation is to use entanglement in the spatial degree of freedom of twin photons created by spontaneous parametric down-conversion, which is equivalent to orbital angular momentum entanglement, this has been proven to be an excellent model system. The use of optical fiber technology for distribution of such photons has only very recently been practically demonstrated and is of fundamental and applied interest. It poses a big challenge compared to the established time and frequency domain methods: For spatially entangled photons, fiber transport requires the use of multimode fibers, and mode coupling and intermodal dispersion therein must be minimized not to destroy the spatial quantum correlations. We demonstrate that these shortcomings of conventional multimode fibers can be overcome by using a hollow-core photonic crystal fiber, which follows the paradigm to mimic free-space transport as good as possible, and are able to confirm entanglement of the fiber-transported photons. Fiber transport of spatially entangled photons is largely unexplored yet, therefore we discuss the main complications, the interplay of intermodal dispersion and mode mixing, the influence of external stress and core deformations, and consider the pros and cons of various fiber types.

  11. Multi-mode to single-mode conversion in a 61 port photonic lantern

    DEFF Research Database (Denmark)

    Noordegraaf, Danny; Skovgaard, Peter M.W.; Maack, Martin D.

    2010-01-01

    Efficient multi-mode (MM) to single-mode (SM) conversion in a 61 port splitter or “Photonic Lantern” is demonstrated. The coupling loss from a 100 µm core diameter MM section to an ensemble of 61 SM fibers and back to another 100 µm core MM section is measured to be as low as 0.76 dB. This demons......B. This demonstration shows the feasibility of using the Photonic Lanterns within the field of astrophotonics for coupling MM star-light to an ensemble of SM fibers in order to perform fiber Bragg grating based spectral filtering."...

  12. Developing Multimodal Academic Literacies among College Freshmen

    Science.gov (United States)

    Jacobs, Gloria E.

    2012-01-01

    In this article, the author draws on a semester long freshmen learning community in which multimodal texts were used as primary texts along with traditional texts to support students' academic literacy skills. Analysis shows that a multimodal text created by students contain elements of academic literacies and qualities of multimodal texts. An…

  13. Adaptive multimodal continuous ant colony optimization

    OpenAIRE

    Yang, Qiang; Chen, Wei-Neng; Yu, Zhengtao; Gu, Tianlong; Li, Yun; Zhang, Huaxiang; Zhang, Jun

    2017-01-01

    Seeking multiple optima simultaneously, which multimodal optimization aims at, has attracted increasing attention but remains challenging. Taking advantage of ant colony optimization algorithms in preserving high diversity, this paper intends to extend ant colony optimization algorithms to deal with multimodal optimization. First, combined with current niching methods, an adaptive multimodal continuous ant colony optimization algorithm is introduced. In this algorithm, an adaptive parameter a...

  14. Multimodal mapping of human skin.

    Science.gov (United States)

    Heuke, S; Vogler, N; Meyer, T; Akimov, D; Kluschke, F; Röwert-Huber, H-J; Lademann, J; Dietzek, B; Popp, J

    2013-10-01

    The combination of coherent anti-Stokes Raman scattering (CARS), second harmonic generation (SHG) and two-photon excited fluorescence (TPEF) imaging--referred to as multimodal imaging--provides complementary contrast based on molecular vibrations, the structure of various tissue components and endogenous fluorophores, respectively. To present a comprehensive overview of the appearance of human skin in multimodal imaging. Multimodal imaging of unstained skin cross-sections of 32 individuals was performed using a laser scanning microscope and picosecond laser pulse for excitation. The epidermis, dermis and subcutis are distinguishable in all three applied modalities, but are unveiled best in multimodal images. While the subcutis is dominated by the CARS signal, predominately SHG and the secondary TPEF signal detect the dermis. In contrast, no SHG signal is detected in the epidermis, whereas CARS and TPEF show equal contributions. Additionally, the appearance of the major skin appendages is described, i.e. the hair follicle, sebaceous and sweat glands, and blood vessels belonging to the vascular system. All four investigated functional units show a characteristic morphochemistry in TPEF and CARS, allowing identification of further subunits, e.g. the major components of the hair follicle, while the SHG signal delineates the localization of the functional units. Multimodal imaging is a powerful tool to investigate human skin by providing high contrast based on the molecular constitution. It is therefore suggested that multimodal imaging has a high potential in application to dermatological research and clinical diagnostics of various skin alterations. © 2013 The Authors BJD © 2013 British Association of Dermatologists.

  15. Crystalline lens radioprotectors

    International Nuclear Information System (INIS)

    Belkacemi, Y.; Pasquier, D.; Castelain, B.; Lartigau, E.; Warnet, J.M.

    2003-01-01

    During more than a half of century, numerous compounds have been tested in different models against radiation-induced cataract. In this report, we will review the radioprotectors that have been already tested for non-human crystalline lens protection. We will focus on the most important published studies in this topic and the mechanisms of cyto-protection reported in. vitro and in. vivo from animals. The most frequent mechanisms incriminated in the cyto-protective effect are: free radical scavenging, limitation of lipid peroxidation, modulation of cycle progression increase of intracellular reduced glutathione pool, reduction of DNA strand breaks and limitation of apoptotic cell death. Arnifostine (or Ethyol) and anethole dithiolethione (or Sulfarlem), already used clinically as chemo- and radio-protectants, could be further test?r for ocular radioprotection particularly for radiation-induced cataract. (author)

  16. Natural fibers

    Science.gov (United States)

    Craig M. Clemons; Daniel F. Caulfield

    2005-01-01

    The term “natural fibers” covers a broad range of vegetable, animal, and mineral fibers. However, in the composites industry, it usually refers to wood fiber and agrobased bast, leaf, seed, and stem fibers. These fibers often contribute greatly to the structural performance of the plant and, when used in plastic composites, can provide significant reinforcement. Below...

  17. Fabrication of longitudinally arbitrary shaped fiber tapers

    Science.gov (United States)

    Nold, J.; Plötner, M.; Böhme, S.; Sattler, B.; deVries, O.; Schreiber, T.; Eberhardt, R.; Tünnermann, A.

    2018-02-01

    We present our current results on the fabrication of arbitrary shaped fiber tapers on our tapering rig using a CO2-laser as heat source. Single mode excitation of multimode fibers as well as changing the fiber geometry in an LPG-like fashion is presented. It is shown that this setup allows for reproducible fabrication of single-mode excitation tapers to extract the fundamental mode (M2 < 1.1) from a 30 μm core having an NA of 0.09.

  18. Focusing over Optical Fiber Using Time Reversal

    DEFF Research Database (Denmark)

    Piels, Molly; Porto da Silva, Edson; Estaran Tolosa, Jose Manuel

    2015-01-01

    A time-reversal array in multimode fiber is proposed for lossless remotely controlled switching using passive optical splitters. The signal to be transmitted is digitally pre-distorted so that it is routed through the physical layer in order to arrive at only one receiver in an array. System...... performance in the presence of additive white gaussian noise, modal group delay, and timing error is investigated numerically for single-mode and 10-mode fiber. Focusing using a two-transmitter array and 44 km of single- mode fiber is demonstrated experimentally for 3 GBd QPSK signals with a bit error rate...

  19. Non-contact optical measurement of lens capsule thickness during simulated accommodation

    Science.gov (United States)

    Ziebarth, Noel; Manns, Fabrice; Acosta, Ana-Carolina; Parel, Jean-Marie

    2005-04-01

    Purpose: To non-invasively measure the thickness of the anterior and posterior lens capsule, and to determine if it significantly changes during accommodation. Methods: Anterior and posterior capsule thickness was measured on post-mortem lenses using a non-contact optical system using a focus-detection technique. The optical system uses a 670nm laser beam delivered to a single-mode fiber coupler. The output of the fiber coupler is focused on the tissue surface using an aspheric lens (NA=0.68) mounted on a translation stage with a motorized actuator. Light reflected from the sample surface is collected by the fiber coupler and sent to a photoreceiver connected to a computer-controlled data acquisition system. Optical intensity peaks are detected when the aspheric lens is focused on the capsule boundaries. The capsule thickness is equal to the distance traveled between two peaks multiplied by the capsule refractive index. Anterior and posterior lens capsule thickness measurements were performed on 18 cynomolgus (age average: 6+/-1 years, range: 4-7 years) eyes, 1 rhesus (age: 2 years) eye, and 12 human (age average: 65+/-16, range: 47-92) eyes during simulated accommodation. The mounted sample was placed under the focusing objective of the optical system so that the light was incident on the center pole. Measurements were taken of the anterior lens capsule in the unstretched and the stretched 5mm states. The lens was flipped, and the same procedure was performed for the posterior lens capsule. Results: The precision of the optical system was determined to be +/-0.5um. The resolution is 4um and the sensitivity is 52dB. The human anterior lens capsule thickness was 6.0+/-1.2um unstretched and 4.9+/-0.9um stretched (p=0.008). The human posterior lens capsule was 5.7+/-1.2um unstretched and 5.7+/-1.4um stretched (p=0.974). The monkey anterior lens capsule thickness was 5.9+/-1.9um unstretched and 4.8+/-1.0um stretched (p=0.002). The monkey posterior lens capsule was 5

  20. The Multimodal Possibilities of Online Instructions

    DEFF Research Database (Denmark)

    Kampf, Constance

    2006-01-01

    The WWW simplifies the process of delivering online instructions through multimodal channels because of the ease of use for voice, video, pictures, and text modes of communication built into it.  Given that instructions are being produced in multimodal format for the WWW, how do multi-modal analy......The WWW simplifies the process of delivering online instructions through multimodal channels because of the ease of use for voice, video, pictures, and text modes of communication built into it.  Given that instructions are being produced in multimodal format for the WWW, how do multi...

  1. Multimodal Aspects of Corporate Social Responsibility Communication

    Directory of Open Access Journals (Sweden)

    Carmen Daniela Maier

    2014-12-01

    Full Text Available This article addresses how the multimodal persuasive strategies of corporate social responsibility communication can highlight a company’s commitment to gender empowerment and environmental protection while advertising simultaneously its products. Drawing on an interdisciplinary methodological framework related to CSR communication, multimodal discourse analysis and gender theory, the article proposes a multimodal analysis model through which it is possible to map and explain the multimodal persuasive strategies employed by Coca-Cola company in their community-related films. By examining the semiotic modes’ interconnectivity and functional differentiation, this analytical endeavour expands the existing research work as the usual textual focus is extended to a multimodal one.

  2. Photorefractive Fibers

    National Research Council Canada - National Science Library

    Kuzyk, Mark G

    2003-01-01

    ... scope of the project. In addition to our work in optical limiting fibers, spillover results included making fiber-based light-sources, writing holograms in fibers, and developing the theory of the limits of the nonlinear...

  3. Contact Lens Wear at Altitude: Subcontact Lens Bubble Formation

    Science.gov (United States)

    1987-11-01

    incidence of (PMMA) lenses . Reported here are the results of contact lens subcontact lens bubble formation under scleral lenses at bubble studies with soft...vision from formation of large bubbles greater than 6,096 m (20,000 It). With soft contact lenses , bubble under their contact lenses . They also found...always located at the limbus and were without sequela to vision or corneal epithelial integrity. scleral lenses used by Jaeckle were permeable to gases

  4. Straylight Measurements in Contact Lens Wear

    NARCIS (Netherlands)

    van der Meulen, Ivanka J. E.; Engelbrecht, Leonore A.; van Vliet, Johannes M. J.; Lapid-Gortzak, Ruth; Nieuwendaal, Carla P.; Mourits, Maarten P.; Schlingemann, Reinier O.; van den Berg, Thomas J. T. P.

    2010-01-01

    Purpose: (1) To quantify the effect of contact lens wear on straylight in rigid and soft contact lens wearers and (2) to relate findings to morphological changes and subjective complaints. Methods: Straylight was measured using the Oculus C-Quant during contact lens wear and after contact lens

  5. Noncontact optical measurement of lens capsule thickness ex vivo

    Science.gov (United States)

    Ziebarth, Noel M.; Manns, Fabrice; Uhlhorn, Stephen; Parel, Jean-Marie

    2004-07-01

    Purpose: To design a non-contact optical system to measure lens capsule thickness in cadaver eyes. Methods: The optical system uses a 670nm laser beam delivered to a single-mode fiber coupler. The output of the fiber coupler is focused onto the tissue using an aspheric lens (NA=0.68) mounted on a motorized translation stage. Light reflected from the sample is collected by the fiber coupler and sent to a silicon photodiode connected to a power meter. Peaks in the power signal are detected when the focal point of the aspheric lens coincides with the capsule boundaries. The capsule thickness is proportional to the distance between successive peaks. Anterior and posterior lens capsule thickness measurements were performed on 13 human, 10 monkey, and 34 New Zealand white rabbit lenses. The cadaver eyes were prepared for optical measurements by bonding a PMMA ring on the sclera. The posterior pole was sectioned, excess vitreous was removed, and the eye was placed on a Teflon slide. The cornea and iris were then sectioned. After the experiments, the lenses were excised, placed in 10% buffered formalin, and prepared for histology. Results: Central anterior lens capsule thickness was 9.4+/-2.9μm (human), 11.2+/-6.6μm (monkey), and 10.3+/-3.6μm (rabbit) optically and 14.9+/-1.6μm (human), 17.7+/-4.9μm (monkey), and 12.6+/-2.3μm (rabbit) histologically. The values for the central posterior capsule were 9.4+/-2.9μm (human), 6.6+/-2.5μm (monkey), and 7.9+/-2.3μm (rabbit) optically and 4.6+/-1.4μm (human), 4.5+/-1.2μm (monkey), and 5.7+/-1.7μm (rabbit) histologically. Conclusions: This study demonstrates that a non-contact optical system can successfully measure lens capsule thickness in cadaver eyes.

  6. Multi-Modality Phantom Development

    Energy Technology Data Exchange (ETDEWEB)

    Huber, Jennifer S.; Peng, Qiyu; Moses, William W.

    2009-03-20

    Multi-modality imaging has an increasing role in the diagnosis and treatment of a large number of diseases, particularly if both functional and anatomical information are acquired and accurately co-registered. Hence, there is a resulting need for multi modality phantoms in order to validate image co-registration and calibrate the imaging systems. We present our PET-ultrasound phantom development, including PET and ultrasound images of a simple prostate phantom. We use agar and gelatin mixed with a radioactive solution. We also present our development of custom multi-modality phantoms that are compatible with PET, transrectal ultrasound (TRUS), MRI and CT imaging. We describe both our selection of tissue mimicking materials and phantom construction procedures. These custom PET-TRUS-CT-MRI prostate phantoms use agargelatin radioactive mixtures with additional contrast agents and preservatives. We show multi-modality images of these custom prostate phantoms, as well as discuss phantom construction alternatives. Although we are currently focused on prostate imaging, this phantom development is applicable to many multi-modality imaging applications.

  7. Multimodal signalling in estrildid finches

    DEFF Research Database (Denmark)

    Gomes, A. C. R.; Funghi, C.; Soma, M.

    2017-01-01

    Sexual traits (e.g. visual ornaments, acoustic signals, courtship behaviour) are often displayed together as multimodal signals. Some hypotheses predict joint evolution of different sexual signals (e.g. to increase the efficiency of communication) or that different signals trade off with each oth...

  8. Brief Psychotherapy: The Multimodal Model.

    Science.gov (United States)

    Lazarus, Arnold A.

    1989-01-01

    Outlines tenets of multimodal therapy (MMT) and argues for its cost-effective yet comprehensive value as a brief psychotherapy model. Describes MMT as an integrated, seven-modality model of personality and provides clinical examples of its use. Argues that MMT approach will be an important future alternative to more expensive, time-consuming, and…

  9. Multimodal approach to postoperative recovery

    DEFF Research Database (Denmark)

    Kehlet, Henrik

    2009-01-01

    PURPOSE OF REVIEW: To provide updated information on recent developments within individual components of multimodal interventions to improve postoperative outcome (fast-track methodology). RECENT FINDINGS: The value of the fast-track methodology to improve recovery and decrease hospital stay and ...

  10. A Learning Algorithm for Multimodal Grammar Inference.

    Science.gov (United States)

    D'Ulizia, A; Ferri, F; Grifoni, P

    2011-12-01

    The high costs of development and maintenance of multimodal grammars in integrating and understanding input in multimodal interfaces lead to the investigation of novel algorithmic solutions in automating grammar generation and in updating processes. Many algorithms for context-free grammar inference have been developed in the natural language processing literature. An extension of these algorithms toward the inference of multimodal grammars is necessary for multimodal input processing. In this paper, we propose a novel grammar inference mechanism that allows us to learn a multimodal grammar from its positive samples of multimodal sentences. The algorithm first generates the multimodal grammar that is able to parse the positive samples of sentences and, afterward, makes use of two learning operators and the minimum description length metrics in improving the grammar description and in avoiding the over-generalization problem. The experimental results highlight the acceptable performances of the algorithm proposed in this paper since it has a very high probability of parsing valid sentences.

  11. Multimode laser beam analyzer instrument using electrically programmable optics.

    Science.gov (United States)

    Marraccini, Philip J; Riza, Nabeel A

    2011-12-01

    Presented is a novel design of a multimode laser beam analyzer using a digital micromirror device (DMD) and an electronically controlled variable focus lens (ECVFL) that serve as the digital and analog agile optics, respectively. The proposed analyzer is a broadband laser characterization instrument that uses the agile optics to smartly direct light to the required point photodetectors to enable beam measurements of minimum beam waist size, minimum waist location, divergence, and the beam propagation parameter M(2). Experimental results successfully demonstrate these measurements for a 500 mW multimode test laser beam with a wavelength of 532 nm. The minimum beam waist, divergence, and M(2) experimental results for the test laser are found to be 257.61 μm, 2.103 mrad, 1.600 and 326.67 μm, 2.682 mrad, 2.587 for the vertical and horizontal directions, respectively. These measurements are compared to a traditional scan method and the results of the beam waist are found to be within error tolerance of the demonstrated instrument.

  12. Advanced signaling technologies for high-speed digital fiber-optic links.

    Science.gov (United States)

    Stark, Andrew J; Isautier, Pierre; Pan, Jie; Pavan, Sriharsha Kota; Filer, Mark; Tibuleac, Sorin; Lingle, Robert; de Salvo, Richard; Ralph, Stephen E

    2014-09-01

    We summarize the most recent research of the Georgia Tech Terabit Optical Networking Consortium and the state-of-the-art in fiber telecommunications. These results comprise high-capacity single-mode fiber systems with digital coherent receivers and shorter-reach multimode fiber links with vertical cavity surface emitting lasers. We strongly emphasize the capabilities that sophisticated digital signal processing and electronics add to these fiber-based data transport links.

  13. Infrared fibers in the 1.5um to 18um range: availability and measured properties

    Science.gov (United States)

    Felkel, Robert; Leeb, Walter

    2017-11-01

    With a view towards the application in space-borne optical instruments, we first performed a world-wide market survey of infrared fibers designed for the wavelength range of 1.5 μm to 18 μm. Fiber samples purchased and tested comprise fluoride fibers, chalcogenide fibers, a germanate fiber and a silver-halide fiber, as well as hollow fibers. While the majority of infrared fibers offered are of the multi-mode type, three of the fluoride fibers are single-mode. We report on the polarization degrading effect of a single-mode fiber and present a possible solution to achieve polarization maintainance by twisting the fiber. Secondly we report on measurements of numerical aperture, output beam profile, and attenuation of a hollow fiber. The measurements were performed at the wavelengths of λ= 3.39 μm and λ= 10.6 μm.

  14. Common path ball lens probe for optical coherence tomography (Conference Presentation)

    Science.gov (United States)

    Singh, Kanwarpal; Yamada, Daisuke; Tearney, Guillermo J.

    2016-02-01

    Background: Common path probes are highly desirable for optical coherence tomography (OCT) as they reduce system complexity and cost. In this work we report an all-fiber common path side viewing monolithic probe for coronary artery imaging. Methods: Our common path probe was designed for spectrometer based Fourier domain OCT at 1310 nm wavelength. Light from the fiber expands in the coreless fiber region and then focussed by the ball lens. Reflection from ball lens-air interface served as reference signal. The monolithic ball lens probe was assembled within a 560 µmouter diameter drive shaft which was attached to a rotary junction. The drive shaft was placed inside an outer, transparent sheath of 800 µm diameter. Results: With a source input power of 25 mW, we could achieve sensitivity of 100.5 dB. The axial resolution of the system was found to be 15.6 µm in air and the lateral resolution (full width half maximum) was approximately 49 µm. As proof of principal, images of skin acquired using this probe demonstrated clear visualization of the stratum corneum, epidermis, and papillary dermis, along with sweat ducts. Conclusion: In this work we have demonstrated a monolithic, ball lens common, path probe for OCT imaging. The designed ball lens probe is easy to fabricate using a laser splicer. Based on the features and capability of common path probes to provide a simpler solution for OCT, we believe that this development will be an important enhancement for certain types of catheters.

  15. The incorporation of 2-[14C]glycine into porcine lens protein

    International Nuclear Information System (INIS)

    Lee, Y.B.; Kauffman, R.G.; DeVenecia, G.

    1977-01-01

    A series of experiments was conducted to estimate the apparent turnover rate of lens soluble protein, the incorporation rate of 2-[ 14 C]glycine into various soluble protein components and the effect of nutritional stress on the disappearance of radioactivity with time. Evidence is presented that there are two fractions of soluble lens protein with different turnover rates: one is a fast turnover fraction with a half-life of 20.8 hr and the other is a metabolically inert fraction with an infinitely long half-life. It is postulated that the fast turnover fraction is present in the newly-formed younger fibers in the periphery, whereas the inert fraction is in the old lens fibers of the cortex and nucleus. Sephadex G-200 column chromatography was used to separate the soluble lens protein into four components: A, B, C and D in the order of elution. The changes in specific activities of the four components with the time course after injection were followed. Prolonged starvation did not affect the disappearance of carbon incorporated into lens protein with the time course after injection, suggesting normal synthesis and degradation of lens protein without regard to dietary stress. (author)

  16. Contact Lens Related Corneal Ulcer

    OpenAIRE

    Loh, KY; Agarwal, P

    2010-01-01

    A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are: overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. Th...

  17. A course in lens design

    CERN Document Server

    Velzel, Chris

    2014-01-01

    A Course in Lens Design is an instruction in the design of image-forming optical systems. It teaches how a satisfactory design can be obtained in a straightforward way. Theory is limited to a minimum, and used to support the practical design work. The book introduces geometrical optics, optical instruments and aberrations. It gives a description of the process of lens design and of the strategies used in this process. Half of its content is devoted to the design of sixteen types of lenses, described in detail from beginning to end. This book is different from most other books on lens design because it stresses the importance of the initial phases of the design process: (paraxial) lay-out and (thin-lens) pre-design. The argument for this change of accent is that in these phases much information can be obtained about the properties of the lens to be designed. This information can be used in later phases of the design. This makes A Course in Lens Design a useful self-study book, and a suitable basis for an intro...

  18. Reliability of high-power multimode pump modules

    Science.gov (United States)

    Pflueger, Silke; Duesterberg, Richard L.; Rossin, Victor V.; Strite, Toby; Tai, Kuochou; Wolak, Edmund L.; Wong, Andre W.; Xu, Lei; Zucker, Erik

    2004-10-01

    Developers building high-power fiber lasers and diode pumped solid state lasers can receive significant benefits in thermal management and reliability by using single emitter multi-mode diodes in distributed pump architectures. This proposed distributed architecture relies on independent single emitter pump lasers and a modest level of pump redundancy. Driving the remaining diodes slightly harder componensates individual diode failures. A model of the ensemble lifetime based on module failure rates and power-scaling factors demonstrates that the distributed pump architecture requires random failure rates corresponding to better than 200,000h mean time between failure (MTBF), which meets typical industrial requirements. A high power, pigtailed, multi-mode pump module suitable for commercial applications is created through this model. Critical elements are based on telecom architectures, including the optical train and the fiber alignment. The module has a low thermal resistance of 4°C/W from the chip-on-sub-mount to the external heat sink, coupling efficiency of over 80% into 0.2 NA, and demonstrated reliable output power of over 5W cw with peak wavelengths near 915 nm. Individual pump modules are predicted to produce 5W cw output power with an MTBF of more than 400,000h. The relationship between anticipated MTBF requirements, test duration and test population is shown.

  19. Gabor lens theory

    International Nuclear Information System (INIS)

    Irani, A.A.

    1978-01-01

    The principle of using the space charge of an electron cloud to focus ion beams was first proposed by Gabor. Electrons are to be confined radially by means of an axial magnetic field B/sub z/ and axially by means of externally applied electric fields E/sub z/. An ion beam of charge density n/sub i/ much less than n/sub e/, the electron charge density can then be focused by the radial electric field set up by the electron cloud. The case considered here is that of a hollow cylindrical conductor charged to a potential +V with grounded rings on either side to set up the axial E/sub z/ field. A solenoid wound around the central conductor supplies the B/sub z/ field. Theoretical calculations are carried out for n/sub e/ maximum as a function of B/sub z/ due to radial confinement and V due to axial confinement and the focal length of the Gabor Lens is calculated

  20. Modal instabilities in very large mode area rod fiber amplifiers

    DEFF Research Database (Denmark)

    Jørgensen, Mette Marie; Hansen, Kristian Rymann; Laurila, Marko

    with the finite element method to allow complex micro structured fibers to be considered. Thereby the modal instability threshold is estimated for very large mode area fiber amplifiers of various photonic crystal fiber designs. Experimentally the modal instability threshold for very large mode area fiber......Optical fiber amplifiers have gained increased scientific and commercial interest due to high output powers with easy operation and maintenance. The main advantages of fiber amplifiers are good thermal properties, due to a large surface/volume ratio, excellent beam quality and stability [1]. Very...... large core fiber areas are highly desirable to mitigate various nonlinear processes, such as Kerr, four-wave mixing, Raman, and Brillouin effects. It is difficult to scale up the core area without going into a multi-moded regime. Microstructured fiber technology has allowed core diameters of 60...

  1. Eye lens membrane junctional microdomains: a comparison between healthy and pathological cases

    Energy Technology Data Exchange (ETDEWEB)

    Buzhynskyy, Nikolay; Scheuring, Simon [Institut Curie, Equipe Inserm Avenir, UMR168-CNRS, 26 Rue d' Ulm, 75248 Paris Cedex 05 (France); Sens, Pierre [ESPCI, CNRS-UMR 7083, 75231 Paris (France); Behar-Cohen, Francine, E-mail: simon.scheuring@curie.fr [UMRS Inserm 872, Universite Paris Descartes, Centre de Recherches des Cordeliers, 15 rue de l' Ecole de Medecine, 75270 Paris Cedex 06 (France)

    2011-08-15

    The eye lens is a transparent tissue constituted of tightly packed fiber cells. To maintain homeostasis and transparency of the lens, the circulation of water, ions and metabolites is required. Junctional microdomains connect the lens cells and ensure both tight cell-to-cell adhesion and intercellular flow of fluids through a microcirculation system. Here, we overview membrane morphology and tissue functional requirements of the mammalian lens. Atomic force microscopy (AFM) has opened up the possibility of visualizing the junctional microdomains at unprecedented submolecular resolution, revealing the supramolecular assembly of lens-specific aquaporin-0 (AQP0) and connexins (Cx). We compare the membrane protein assembly in healthy lenses with senile and diabetes-II cataract cases and novel data of the lens membranes from a congenital cataract. In the healthy case, AQP0s form characteristic square arrays confined by connexons. In the cases of senile and diabetes-II cataract patients, connexons were degraded, leading to malformation of AQP0 arrays and breakdown of the microcirculation system. In the congenital cataract, connexons are present, indicating probable non-membranous grounds for lens opacification. Further, we discuss the energetic aspects of the membrane organization in junctional microdomains. The AFM hence becomes a biomedical nano-imaging tool for the analysis of single-membrane protein supramolecular association in healthy and pathological membranes.

  2. Eye lens membrane junctional microdomains: a comparison between healthy and pathological cases

    Science.gov (United States)

    Buzhynskyy, Nikolay; Sens, Pierre; Behar-Cohen, Francine; Scheuring, Simon

    2011-08-01

    The eye lens is a transparent tissue constituted of tightly packed fiber cells. To maintain homeostasis and transparency of the lens, the circulation of water, ions and metabolites is required. Junctional microdomains connect the lens cells and ensure both tight cell-to-cell adhesion and intercellular flow of fluids through a microcirculation system. Here, we overview membrane morphology and tissue functional requirements of the mammalian lens. Atomic force microscopy (AFM) has opened up the possibility of visualizing the junctional microdomains at unprecedented submolecular resolution, revealing the supramolecular assembly of lens-specific aquaporin-0 (AQP0) and connexins (Cx). We compare the membrane protein assembly in healthy lenses with senile and diabetes-II cataract cases and novel data of the lens membranes from a congenital cataract. In the healthy case, AQP0s form characteristic square arrays confined by connexons. In the cases of senile and diabetes-II cataract patients, connexons were degraded, leading to malformation of AQP0 arrays and breakdown of the microcirculation system. In the congenital cataract, connexons are present, indicating probable non-membranous grounds for lens opacification. Further, we discuss the energetic aspects of the membrane organization in junctional microdomains. The AFM hence becomes a biomedical nano-imaging tool for the analysis of single-membrane protein supramolecular association in healthy and pathological membranes.

  3. Radiocarbon dating of the human eye lens crystallines reveal proteins without carbon turnover throughout life.

    Directory of Open Access Journals (Sweden)

    Niels Lynnerup

    Full Text Available BACKGROUND: Lens crystallines are special proteins in the eye lens. Because the epithelial basement membrane (lens capsule completely encloses the lens, desquamation of aging cells is impossible, and due to the complete absence of blood vessels or transport of metabolites in this area, there is no subsequent remodelling of these fibers, nor removal of degraded lens fibers. Human tissue ultimately derives its (14C content from the atmospheric carbon dioxide. The (14C content of the lens proteins thus reflects the atmospheric content of (14C when the lens crystallines were formed. Precise radiocarbon dating is made possible by comparing the (14C content of the lens crystallines to the so-called bomb pulse, i.e. a plot of the atmospheric (14C content since the Second World War, when there was a significant increase due to nuclear-bomb testing. Since the change in concentration is significant even on a yearly basis this allows very accurate dating. METHODOLOGY/PRINCIPAL FINDINGS: Our results allow us to conclude that the crystalline formation in the lens nucleus almost entirely takes place around the time of birth, with a very small, and decreasing, continuous formation throughout life. The close relationship may be further expressed as a mathematical model, which takes into account the timing of the crystalline formation. CONCLUSIONS/SIGNIFICANCE: Such a life-long permanence of human tissue has hitherto only been described for dental enamel. In confront to dental enamel it must be held in mind that the eye lens is a soft structure, subjected to almost continuous deformation, due to lens accommodation, yet its most important constituent, the lens crystalline, is never subject to turnover or remodelling once formed. The determination of the (14C content of various tissues may be used to assess turnover rates and degree of substitution (for example for brain cell DNA. Potential targets may be nervous tissues in terms of senile or pre

  4. Fiber Amplifiers

    DEFF Research Database (Denmark)

    Rottwitt, Karsten

    2017-01-01

    The chapter provides a discussion of optical fiber amplifiers and through three sections provides a detailed treatment of three types of optical fiber amplifiers, erbium doped fiber amplifiers (EDFA), Raman amplifiers, and parametric amplifiers. Each section comprises the fundamentals including...... the basic physics and relevant in-depth theoretical modeling, amplifiers characteristics and performance data as a function of specific operation parameters. Typical applications in fiber optic communication systems and the improvement achievable through the use of fiber amplifiers are illustrated....

  5. Gastric Adenocarcinoma: A Multimodal Approach

    Directory of Open Access Journals (Sweden)

    Humair S. Quadri

    2017-08-01

    Full Text Available Despite its declining incidence, gastric cancer (GC remains a leading cause of cancer-related deaths worldwide. A multimodal approach to GC is critical to ensure optimal patient outcomes. Pretherapy fine resolution contrast-enhanced cross-sectional imaging, endoscopic ultrasound and staging laparoscopy play an important role in patients with newly diagnosed ostensibly operable GC to avoid unnecessary non-therapeutic laparotomies. Currently, margin negative gastrectomy and adequate lymphadenectomy performed at high volume hospitals remain the backbone of GC treatment. Importantly, adequate GC surgery should be integrated in the setting of a multimodal treatment approach. Treatment for advanced GC continues to expand with the emergence of additional lines of systemic and targeted therapies.

  6. Inorganic Nanoparticles for Multimodal Molecular Imaging

    Directory of Open Access Journals (Sweden)

    Magdalena Swierczewska

    2011-01-01

    Full Text Available Multimodal molecular imaging can offer a synergistic improvement of diagnostic ability over a single imaging modality. Recent development of hybrid imaging systems has profoundly impacted the pool of available multimodal imaging probes. In particular, much interest has been focused on biocompatible, inorganic nanoparticle-based multimodal probes. Inorganic nanoparticles offer exceptional advantages to the field of multimodal imaging owing to their unique characteristics, such as nanometer dimensions, tunable imaging properties, and multifunctionality. Nanoparticles mainly based on iron oxide, quantum dots, gold, and silica have been applied to various imaging modalities to characterize and image specific biologic processes on a molecular level. A combination of nanoparticles and other materials such as biomolecules, polymers, and radiometals continue to increase functionality for in vivo multimodal imaging and therapeutic agents. In this review, we discuss the unique concepts, characteristics, and applications of the various multimodal imaging probes based on inorganic nanoparticles.

  7. [Contact lens care and maintenance].

    Science.gov (United States)

    Bloise, L

    2017-04-01

    All contact lenses with replacement schedules longer than daily must be maintained. At each step of their use, the lenses may be contaminated. Contact lens solutions perform the essential functions of cleaning, decontaminating and preserving the lenses to prevent infectious problems and improve wearing comfort. Contact lens contamination essentially comes from hands, cleaning solutions, cases, water and the environment. The pathogenic microorganisms are mainly Gram-negative bacteria, fungi and amoebae. Contact lens deposits may or may not have an organic origin. Their presence increases the risk of infection because they serve as a nutrient matrix for microbes, and they are responsible for wearing discomfort. Contact lens solutions differ in their composition, their mechanism of action and the concentration of the various agents. To prescribe the best lens care system to each wearer and for each material, it is necessary to be very familiar with them. Maintenance is the main cause of discomfort with contact lenses, either through improper use, solution-material incompatibility, or a reaction of the wearer to the components. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  8. Multimodal Diversity of Postmodernist Fiction Text

    Directory of Open Access Journals (Sweden)

    U. I. Tykha

    2016-12-01

    Full Text Available The article is devoted to the analysis of structural and functional manifestations of multimodal diversity in postmodernist fiction texts. Multimodality is defined as the coexistence of more than one semiotic mode within a certain context. Multimodal texts feature a diversity of semiotic modes in the communication and development of their narrative. Such experimental texts subvert conventional patterns by introducing various semiotic resources – verbal or non-verbal.

  9. Tensor Fusion Network for Multimodal Sentiment Analysis

    OpenAIRE

    Zadeh, Amir; Chen, Minghai; Poria, Soujanya; Cambria, Erik; Morency, Louis-Philippe

    2017-01-01

    Multimodal sentiment analysis is an increasingly popular research area, which extends the conventional language-based definition of sentiment analysis to a multimodal setup where other relevant modalities accompany language. In this paper, we pose the problem of multimodal sentiment analysis as modeling intra-modality and inter-modality dynamics. We introduce a novel model, termed Tensor Fusion Network, which learns both such dynamics end-to-end. The proposed approach is tailored for the vola...

  10. Multimodal exemplification: The expansion of meaning in electronic ...

    African Journals Online (AJOL)

    Functional Multimodal Discourse Analysis (SF-MDA) and argues for improving their exemplifica-tion multimodally. Multimodal devices, if well coordinated, can help optimize e-dictionary exam-ples in informativity, diversity, dynamicity and ...

  11. Fiber optic temperature sensor depositing quantum dots inside hollow core fibers using the layer by layer technique

    Science.gov (United States)

    Bravo, Javier; Goicoechea, Javier; Corres, Jesús M.; Arregui, Francisco J.; Matias, Ignacio R.

    2007-07-01

    CdTe Quantum Dots (4 nm of diameter) have been successfully deposited on the inner part of hollow core fibers using the Layer-by-Layer Electrostatic Self-Assembly method. The architecture of the sensor consists on a short section of a hollow core fiber tapered at both ends and spliced to standard multimode optical fibers. Taking advantage of the dependence on temperature of the green fluorescent emission of the Quantum Dot sensitive nanofilms, optical fiber sensors were fabricated and experimentally demonstrated.

  12. Design and performance evaluation of 1-by-64 multimode interference power splitter for optical communications

    DEFF Research Database (Denmark)

    Rasmussen, Thomas; Rasmussen, Jesper Kiel; Povlsen, Jørn Hedegaard

    1995-01-01

    A 1-by-64 multimode interference power splitter in SiO2 has been designed for use in fiber-optics communication systems. The splitter exhibits a minimum loss of 0.5 db and a uniformity of 1.7 dB at a wavelength of 1.55 μm. The polarization sensitivity is below 0.14 dB, the reflection level below ...

  13. Quality and performance of laser cutting with a high power SM fiber laser

    DEFF Research Database (Denmark)

    Kristiansen, Morten; Selchau, Jacob; Olsen, F. O.

    2013-01-01

    The introduction of high power single mode fiber lasers allows for a beam of high power and a good beam quality factor (M2 ” 1.2), compared to the multimode fiber lasers often utilised in macro laser metal cutting. This paper describes fundamental studies of macro laser metal cutting with a singl...

  14. The SNAP Strong Lens Survey

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, P.

    2005-01-03

    Basic considerations of lens detection and identification indicate that a wide field survey of the types planned for weak lensing and Type Ia SNe with SNAP are close to optimal for the optical detection of strong lenses. Such a ''piggy-back'' survey might be expected even pessimistically to provide a catalogue of a few thousand new strong lenses, with the numbers dominated by systems of faint blue galaxies lensed by foreground ellipticals. After sketching out our strategy for detecting and measuring these galaxy lenses using the SNAP images, we discuss some of the scientific applications of such a large sample of gravitational lenses: in particular we comment on the partition of information between lens structure, the source population properties and cosmology. Understanding this partitioning is key to assessing strong lens cosmography's value as a cosmological probe.

  15. Automated Fresnel lens tester system

    Energy Technology Data Exchange (ETDEWEB)

    Phipps, G.S.

    1981-07-01

    An automated data collection system controlled by a desktop computer has been developed for testing Fresnel concentrators (lenses) intended for solar energy applications. The system maps the two-dimensional irradiance pattern (image) formed in a plane parallel to the lens, whereas the lens and detector assembly track the sun. A point detector silicon diode (0.5-mm-dia active area) measures the irradiance at each point of an operator-defined rectilinear grid of data positions. Comparison with a second detector measuring solar insolation levels results in solar concentration ratios over the image plane. Summation of image plane energies allows calculation of lens efficiencies for various solar cell sizes. Various graphical plots of concentration ratio data help to visualize energy distribution patterns.

  16. Compliance among soft contact lens wearers.

    Science.gov (United States)

    Kuzman, Tomislav; Kutija, Marija Barisić; Masnec, Sanja; Jandroković, Sonja; Mrazovac, Danijela; Jurisić, Darija; Skegro, Ivan; Kalauz, Miro; Kordić, Rajko

    2014-12-01

    Contact lens compliance is proven to be crucial for preventing lens wear-related complications because of the interdependence of the steps in lens care regime and their influence on lens system microbial contamination. Awareness of the patients' lens handling compliance as well as correct recognition of non-compliant behaviours is the basis for creating more targeted strategies for patient education. The aim of this study was to investigate compliance among soft contact lens (SCL) wearers in different aspects of lens care handling and wearing habits. In our research 50 asymptomatic lens wearers filled out a questionnaire containing demographic data, lens type, hygiene and wearing habits, lenses and lens care system replacement schedule and self-evaluation of contact lens handling hygiene. We established criteria of compliance according to available manufacturer's recommendations, prior literature and our clinical experience. Only 2 (4%) of patients were fully compliant SCL wearers. The most common non-compliant behaviours were insufficient lens solution soaking time (62%), followed by failure to daily exchange lens case solution and showering while wearing lenses. 44% of patients reported storing lenses in saline solution. Mean lens storage case replacement was 3.6 months, with up to 78% patients replacing lens case at least once in 3 months. Average grade in self evaluating level of compliance was very good (4 +/- 0.78) (from 1-poor level of hygiene to 5-great level of hygiene). Lens wearers who reported excessive daily lens wear and more than 10 years of lens wearing experience were also found to be less compliant with other lens system care procedures. (t = -2.99, df=47, p lens system maintenance steps. Most common non-compliant behaviours were the ones that are crucial for maintaining lens sterility and preventing infection. Despite the low objective compliance rate, self grading was relatively high. Therefore, these results indicate the need for patient

  17. An Electromagnetic Sensor with a Metamaterial Lens for Nondestructive Evaluation of Composite Materials

    Directory of Open Access Journals (Sweden)

    Adriana Savin

    2015-07-01

    Full Text Available This paper proposes the study and implementation of a sensor with a metamaterial (MM lens in electromagnetic nondestructive evaluation (eNDE. Thus, the use of a new type of MM, named Conical Swiss Rolls (CSR has been proposed. These structures can serve as electromagnetic flux concentrators in the radiofrequency range. As a direct application, plates of composite materials with carbon fibers woven as reinforcement and polyphenylene sulphide as matrix with delaminations due to low energy impacts were examined. The evaluation method is based on the appearance of evanescent modes in the space between carbon fibers when the sample is excited with a transversal magnetic along z axis (TMz polarized electromagnetic field. The MM lens allows the transmission and intensification of evanescent waves. The characteristics of carbon fibers woven structure became visible and delaminations are clearly emphasized. The flaws can be localized with spatial resolution better than λ/2000.

  18. Proximal fiber tip damage during Holmium:YAG and thulium fiber laser ablation of kidney stones

    Science.gov (United States)

    Wilson, Christopher R.; Hardy, Luke A.; Irby, Pierce B.; Fried, Nathaniel M.

    2016-02-01

    The Thulium fiber laser (TFL) is being studied as an alternative to Holmium:YAG laser for lithotripsy. TFL beam originates within an 18-μm-core thulium doped silica fiber, and its near single mode, Gaussian beam profile enables transmission of higher laser power through smaller fibers than possible during Holmium laser lithotripsy. This study examines whether TFL beam profile also reduces proximal fiber tip damage compared to Holmium laser multimodal beam. TFL beam at wavelength of 1908 nm was coupled into 105-μm-core silica fibers, with 35-mJ energy, 500-μs pulse duration, and pulse rates of 50-500 Hz. For each pulse rate, 500,000 pulses were delivered. Magnified images of proximal fiber surfaces were taken before and after each trial. For comparison, 20 single-use, 270-μm-core fibers were collected after clinical Holmium laser lithotripsy procedures using standard settings (600 mJ, 350 μs, 6 Hz). Total laser energy, number of laser pulses, and laser irradiation time were recorded, and fibers were rated for damage. For TFL studies, output power was stable, and no proximal fiber damage was observed after delivery of 500,000 pulses at settings up to 35 mJ, 500 Hz, and 17.5 W average power. In contrast, confocal microscopy images of fiber tips after Holmium lithotripsy showed proximal fiber tip degradation in all 20 fibers. The proximal fiber tip of a 105-μm-core fiber transmitted 17.5 W of TFL power without degradation, compared to degradation of 270-μm-core fibers after transmission of 3.6 W of Holmium laser power. The smaller and more uniform TFL beam profile may improve fiber lifetime, and potentially reduce costs for the surgical disposables as well.

  19. Endogenous hydrogen peroxide production in the epithelium of the developing embryonic lens.

    Science.gov (United States)

    Basu, Subhasree; Rajakaruna, Suren; Dickinson, Bryan C; Chang, Christopher J; Menko, A Sue

    2014-01-01

    Hydrogen peroxide (H2O2) is an endogenously produced reactive oxygen species (ROS) present in a variety of mammalian systems. This particular ROS can play dichotomous roles, being beneficial in some cases and deleterious in others, which reflects the level and location of H2O2 production. While much is known about the redox regulation of ROS by antioxidant and repair systems in the lens, little is known about the endogenous production of H2O2 in embryonic lens tissue or the physiologic relevance of endogenous H2O2 to lens development. This gap in knowledge exists primarily from a lack of reagents that can specifically detect endogenous H2O2 in the intact lens. Here, using a recently developed chemoselective fluorescent boronate probe, peroxyfluor-6 acetoxymethyl ester (PF6-AM), which selectively detects H2O2 over related ROS, we examined the endogenous H2O2 signals in the embryonic lens. Embryonic day 10 chick whole lenses in ex vivo organ culture and lens epithelial cells in primary culture were loaded with the H2O2 probe PF6-AM. To determine the relationship between localization of mitochondria with active membrane potential and the region of H2O2 production in the lens, cells were exposed to the mitochondrial probe MitoTracker Red CMXRos together with PF6-AM. Diphenyleneiodonium (DPI), a flavin inhibitor that blocks generation of intracellular ROS production, was used to confirm that the signal from PF6-AM was due to endogenous ROS production. All imaging was performed by live confocal microscopy. PF6-AM detected endogenous H2O2 in lens epithelial cells in whole lenses in ex vivo culture and in lens epithelial cells grown in primary culture. No endogenous H2O2 signal could be detected in differentiating lens fiber cells with this probe. Treatment with DPI markedly attenuated the fluorescence signal from the peroxide-specific probe PF6-AM in the lens epithelium, suggesting that basal generation of ROS occurs in this region. The lens epithelial cells producing an

  20. Computer-aided lens assembly

    Science.gov (United States)

    Tomlinson, Richard; Alcock, Rob; Petzing, Jon; Coupland, Jeremy

    2004-01-01

    We propose a computer-aided method of lens manufacture that allows assembly, adjustment, and test phases to be run concurrently until an acceptable level of optical performance is reached. Misalignment of elements within a compound lens is determined by a comparison of the results of physical ray tracing by use of an array of Gaussian laser beams with numerically obtained geometric ray traces. An estimate of misalignment errors is made, and individual elements are adjusted in an iterative manner until performance criteria are achieved. The method is illustrated for the alignment of an air-spaced doublet.

  1. Acanthamoeba keratitis. Contact lens and noncontact lens characteristics.

    Science.gov (United States)

    Chynn, E W; Lopez, M A; Pavan-Langston, D; Talamo, J H

    1995-09-01

    To identify potential differences in time to diagnosis and final visual outcome between contact lens and noncontact lens users with Acanthamoeba keratitis. Prior studies have shown early diagnosis and therapy to be related to outcome but have not analyzed differences among patients with and without contact lenses. A retrospective analysis of 11 consecutive cases (involving 13 eyes) of Acanthamoeba keratitis diagnosed at one institution over a 3-year period. Mean time to diagnosis was significantly longer in noncontact lens users versus those who wore contact lenses (mean, 5.8 versus 3.3 weeks). Fifty percent of patients who did not wear contact lenses had a poor outcome (visual acuity worse than 20/40 or penetrating keratoplasty) versus 14% of patients who wore contact lenses. Diagnoses were made later in patients without contact lenses, and these patients had a worse visual outcome than those with Acanthamoeba keratitis who wore contact lenses. All patients with unresponsive microbial keratitis, even those without contact lens use, should be evaluated for Acanthamoeba.

  2. Lens Subluxation after Plasmin and SF6 Injections in Rabbit Eyes

    Science.gov (United States)

    Wu, Wei-Chi; Liu, Chi-Hsien; Wang, Nan-Kai; Chen, Kwan-Jen; Chen, Tun-Lu; Hwang, Yih-Shiou; Liao, Pei-Ju; Li, Lien-Min; Lai, Chi-Chun

    2014-01-01

    Purpose To investigate the rate of lens subluxation following plasmin and/or SF6 injections in eyes, and whether a subsequent elevated level of vascular endothelial growth factor (VEGF) and vitreous tap would aggravate subluxation. Methods Four groups of rabbits were used. Group 1 received an intravitreal injection (IVI) of plasmin and SF6 in the right eye; group 2 received an IVI of plasmin in the right eye; group 3 received an IVI of SF6 in the right eye; and group 4 received an IVI of balanced salt solution in the right eye. After treatment, IVIs of VEGF were given and vitreous tap was performed three times, followed by clinical observation of lens subluxation and scanning electronic microscope evaluation of the zonular fibers. Results After IVIs of plasmin and SF6, and VEGF and vitreous tap had been performed one to three times, lens subluxation was noted in 0%, 43%, 71%, 71%, and 86% of the eyes in group 1. After IVIs of plasmin, VEGF, and vitreous tap had been performed one to three times, lens subluxation was noted in 11%, 22%, 44%, 44%, and 67% of the eyes in group 2. The eyes in group 3 and 4 did not show signs of lens subluxation after VEGF IVIs and vitreous tap. Histology confirmed zonular fiber damage in the eyes treated with plasmin. Conclusions The incidence of lens subluxation increased following plasmin injections in the eyes, and this was aggravated by the subsequent high VEGF level in the eyes and vitreous tapping. Zonular fibers were disrupted following plasmin treatment. These effects should be kept in mind when using plasmin enzymes in patients with vitreoretinal abnormalities. PMID:25397749

  3. Lens subluxation after plasmin and SF6 injections in rabbit eyes.

    Directory of Open Access Journals (Sweden)

    Wei-Chi Wu

    Full Text Available To investigate the rate of lens subluxation following plasmin and/or SF6 injections in eyes, and whether a subsequent elevated level of vascular endothelial growth factor (VEGF and vitreous tap would aggravate subluxation.Four groups of rabbits were used. Group 1 received an intravitreal injection (IVI of plasmin and SF6 in the right eye; group 2 received an IVI of plasmin in the right eye; group 3 received an IVI of SF6 in the right eye; and group 4 received an IVI of balanced salt solution in the right eye. After treatment, IVIs of VEGF were given and vitreous tap was performed three times, followed by clinical observation of lens subluxation and scanning electronic microscope evaluation of the zonular fibers.After IVIs of plasmin and SF6, and VEGF and vitreous tap had been performed one to three times, lens subluxation was noted in 0%, 43%, 71%, 71%, and 86% of the eyes in group 1. After IVIs of plasmin, VEGF, and vitreous tap had been performed one to three times, lens subluxation was noted in 11%, 22%, 44%, 44%, and 67% of the eyes in group 2. The eyes in group 3 and 4 did not show signs of lens subluxation after VEGF IVIs and vitreous tap. Histology confirmed zonular fiber damage in the eyes treated with plasmin.The incidence of lens subluxation increased following plasmin injections in the eyes, and this was aggravated by the subsequent high VEGF level in the eyes and vitreous tapping. Zonular fibers were disrupted following plasmin treatment. These effects should be kept in mind when using plasmin enzymes in patients with vitreoretinal abnormalities.

  4. Pax6- and Six3-mediated induction of lens cell fate in mouse and human ES cells.

    Directory of Open Access Journals (Sweden)

    Raymond M Anchan

    Full Text Available Embryonic stem (ES cells provide a potentially useful in vitro model for the study of in vivo tissue differentiation. We used mouse and human ES cells to investigate whether the lens regulatory genes Pax6 and Six3 could induce lens cell fate in vitro. To help assess the onset of lens differentiation, we derived a new mES cell line (Pax6-GFP mES that expresses a GFP reporter under the control of the Pax6 P0 promoter and lens ectoderm enhancer. Pax6 or Six3 expression vectors were introduced into mES or hES cells by transfection or lentiviral infection and the differentiating ES cells analyzed for lens marker expression. Transfection of mES cells with Pax6 or Six3 but not with other genes induced the expression of lens cell markers and up-regulated GFP reporter expression in Pax6-GFP mES cells by 3 days post-transfection. By 7 days post-transfection, mES cell cultures exhibited a>10-fold increase over controls in the number of colonies expressing γA-crystallin, a lens fiber cell differentiation marker. RT-PCR and immunostaining revealed induction of additional lens epithelial or fiber cell differentiation markers including Foxe3, Prox1, α- and β-crystallins, and Tdrd7. Moreover, γA-crystallin- or Prox1-expressing lentoid bodies formed by 30 days in culture. In hES cells, Pax6 or Six3 lentiviral vectors also induced lens marker expression. mES cells that express lens markers reside close to but are distinct from the Pax6 or Six3 transduced cells, suggesting that the latter induce nearby undifferentiated ES cells to adopt a lens fate by non-cell autonomous mechanisms. In sum, we describe a novel mES cell GFP reporter line that is useful for monitoring induction of lens fate, and demonstrate that Pax6 or Six3 is sufficient to induce ES cells to adopt a lens fate, potentially via non-cell autonomous mechanisms. These findings should facilitate investigations of lens development.

  5. A microcapillary lens for X-rays

    CERN Document Server

    Dudchik, Y I

    1999-01-01

    A new design of a compound refractive lens for X-rays is proposed. The lens is made as a set of glue microlenses placed in a glass capillary. The technique of lens fabrication is described. Results of ray tracing calculations for 8 and 15 keV photons are represented.

  6. Measurement of peak temperature along an optical fiber

    International Nuclear Information System (INIS)

    Fox, R.J.

    1983-01-01

    A multimode silica-clad optical fiber with a liquid silicone core was used as a distributed-line peak-temperature sensor over a temperature range from ambient to 190 0 C. The maximum error was 2 0 C and was essentially independent of the length or position of the hot zone

  7. Expression of truncated PITX3 in the developing lens leads to microphthalmia and aphakia in mice.

    Directory of Open Access Journals (Sweden)

    Kenta Wada

    Full Text Available Microphthalmia is a severe ocular disorder, and this condition is typically caused by mutations in transcription factors that are involved in eye development. Mice carrying mutations in these transcription factors would be useful tools for defining the mechanisms underlying developmental eye disorders. We discovered a new spontaneous recessive microphthalmos mouse mutant in the Japanese wild-derived inbred strain KOR1/Stm. The homozygous mutant mice were histologically characterized as microphthalmic by the absence of crystallin in the lens, a condition referred to as aphakia. By positional cloning, we identified the nonsense mutation c.444C>A outside the genomic region that encodes the homeodomain of the paired-like homeodomain transcription factor 3 gene (Pitx3 as the mutation responsible for the microphthalmia and aphakia. We examined Pitx3 mRNA expression of mutant mice during embryonic stages using RT-PCR and found that the expression levels are higher than in wild-type mice. Pitx3 over-expression in the lens during developmental stages was also confirmed at the protein level in the microphthalmos mutants via immunohistochemical analyses. Although lens fiber differentiation was not observed in the mutants, strong PITX3 protein signals were observed in the lens vesicles of the mutant lens. Thus, we speculated that abnormal PITX3, which lacks the C-terminus (including the OAR domain as a result of the nonsense mutation, is expressed in mutant lenses. We showed that the expression of the downstream genes Foxe3, Prox1, and Mip was altered because of the Pitx3 mutation, with large reductions in the lens vesicles in the mutants. Similar profiles were observed by immunohistochemical analysis of these proteins. The expression profiles of crystallins were also altered in the mutants. Therefore, we speculated that the microphthalmos/aphakia in this mutant is caused by the expression of truncated PITX3, resulting in the abnormal expression of

  8. Tethered capsule OCT endomicroscopy for upper gastrointestinal tract imaging by using ball lens probe (Conference Presentation)

    Science.gov (United States)

    Dong, Jing; Gora, Michalina J.; Reddy, Rohith; Trasischker, Wolfgang; Poupart, Oriane; Lu, Weina; Carruth, Robert W.; Grant, Catriona N.; Soomro, Amna R.; Tiernan, Aubrey R.; Rosenberg, Mireille; Nishioka, Norman S.; Tearney, Guillermo J.

    2016-03-01

    While endoscopy is the most commonly used modality for diagnosing upper GI tract disease, this procedure usually requires patient sedation that increases cost and mandates its operation in specialized settings. In addition, endoscopy only visualizes tissue superfically at the macroscopic scale, which is problematic for many diseases that manifest below the surface at a microscopic scale. Our lab has previously developed technology termed tethered capsule OCT endomicroscopy (TCE) to overcome these diagnostic limitations of endoscopy. The TCE device is a swallowable capsule that contains optomechanical components that circumferentially scan the OCT beam inside the body as the pill traverses the organ via peristalsis. While we have successfully imaged ~100 patients with the TCE device, the optics of our current device have many elements and are complex, comprising a glass ferrule, optical fiber, glass spacer, GRIN lens and prism. As we scale up manufacturing of this device for clinical translation, we must decrease the cost and improve the manufacturability of the capsule's optical configuration. In this abstract, we report on the design and development of simplificed TCE optics that replace the GRIN lens-based configuration with an angle-polished ball lens design. The new optics include a single mode optical fiber, a glass spacer and an angle polished ball lens, that are all fusion spliced together. The ball lens capsule has resolutions that are comparable with those of our previous GRIN lens configuration (30µm (lateral) × 7 µm (axial)). Results in human subjects show that OCT-based TCE using the ball lens not only provides rapid, high quality microstructural images of upper GI tract, but also makes it possible to implement this technology inexpensively and on a larger scale.

  9. ORIGINAL ARTICLE Multimodal magnetic resonance imaging ...

    African Journals Online (AJOL)

    data on the added utility of multimodal MRI (performed at 3 Tesla MR field strength) for accurate diagnosis, compared with that obtained by biopsy, or comparing the diagnostic accuracy of conventional MRI with that of multimodal MRI, when the aforementioned proposed criteria are used in the evaluation. Most reports in the ...

  10. Evaluating Multimodal Literacies in Student Blogs

    Science.gov (United States)

    O'Byrne, Barbara; Murrell, Stacey

    2014-01-01

    This research presents ways in which high school students used the multimodal and interactive affordances of blogs to create, organize, communicate and participate on an educational blog. Their actions demonstrated how plural modes of literacy are infiltrating digital environments and reshaping literacy and learning. Multimodal blogging practices…

  11. Literacy, Media and Multimodality: A Critical Response

    Science.gov (United States)

    Bazalgette, Cary; Buckingham, David

    2013-01-01

    In recent years, literacy educators have increasingly recognised the importance of addressing a broader range of texts in the classroom. This article raises some critical concerns about a particular approach to this issue that has been widely promoted in recent years-- the concept of "multimodality". Multimodality theory offers a broadly…

  12. Multimodal Pedagogies for Teacher Education in TESOL

    Science.gov (United States)

    Yi, Youngjoo; Angay-Crowder, Tuba

    2016-01-01

    As a growing number of English language learners (ELLs) engage in digital and multimodal literacy practices in their daily lives, teachers are starting to incorporate multimodal approaches into their instruction. However, anecdotal and empirical evidence shows that teachers often feel unprepared for integrating such practices into their curricula…

  13. Multimodal Trip Planner System final evaluation report.

    Science.gov (United States)

    2011-05-01

    This evaluation of the Multimodal Trip Planning System (MMTPS) is the culmination of a multi-year project evaluating the development and deployment of a multimodal trip planner in the Chicagoland area between 2004 and 2010. The report includes an ove...

  14. Filter. Remix. Make.: Cultivating Adaptability through Multimodality

    Science.gov (United States)

    Dusenberry, Lisa; Hutter, Liz; Robinson, Joy

    2015-01-01

    This article establishes traits of adaptable communicators in the 21st century, explains why adaptability should be a goal of technical communication educators, and shows how multimodal pedagogy supports adaptability. Three examples of scalable, multimodal assignments (infographics, research interviews, and software demonstrations) that evidence…

  15. {PET}ECUBE: a Multimodal Feedback Interface

    OpenAIRE

    Bennett, Peter

    2006-01-01

    The PETECUBE project consists of a series of musical interfaces designed to explore multi-modal feedback. This paper will briefly describe the definition of multimodal feedback, the aim of the project, the development of the first PETECUBE and proposed further work.

  16. The Ultrawideband Leaky Lens Antenna

    NARCIS (Netherlands)

    Bruni, S.; Neto, A.; Marliani, F.

    2007-01-01

    A novel directive and nondispersive antenna is presented: the ultrawideband (UWB) leaky lens. It is based on the broad band Cherenkov radiation occurring at a slot printed between different infinite homogeneous dielectrics. The first part of the paper presents the antenna concept and the UWB design.

  17. ECTOPIC LENS EXTRACTION IN CHILDREN

    Directory of Open Access Journals (Sweden)

    Vladimir Pfeifer

    2002-12-01

    Full Text Available Background. Ectopia lentis continues to be a therapeutic challenge for ophthalmologists. It can occur as an isolated condition, after ocular trauma, in association with other ocular disorders, as part of a systemic mesodermal disease or a complication of general metabolic disorders. Minimal subluxation of the lens may cause no visual symptoms, but in more advanced cases serious optical disturbances arise. The most important is amblyopia. Surgical treatment options include iris manipulation, lens discission, aspiration, intracapsular or extracapsular extraction, and pars plana lensectomy. The choice of surgical technique remains controversial, in part because of the historically poor visual results and high rate of perioperative complications, including vitreous loss and retinal detachment.Methods. We describe a surgical technique based on the use of the Cionni endocapsular tension ring, dry irrigation aspiration of lens material, centration of the capsular bag and foldable intraocular lens implantation into the bag. With mentioned surgical technique 8 patients were operated; 4 boys and 4 girls, together 11 eyes.Results. The final BCVA after follow up period improved in 9 eyes and it remained the same as before operation in one eye. Statistical comparison of preoperative and postoperative visual acuities showed significant improvement. On the other hand there was no correlation between preoperative and postoperative visual acuity.Conclusions. This surgical procedure is an alternative approach in solving this challenging cases of ectopia lentis with good postoperative visual rehabilitation.

  18. Spinning pipe gas lens revisited

    CSIR Research Space (South Africa)

    Mafusire, C

    2008-01-01

    Full Text Available , there is little information on optical phase aberrations and no study to date on the propagation parameters of the laser beam, but has rather remained rooted in the domain of ray optics. Researchers revisit the spinning pipe gas lens in this paper with new...

  19. Optimized fiber delivery system for Q-switched, Nd:YAG lasers

    International Nuclear Information System (INIS)

    Setchell, R.E.

    1997-01-01

    Interest in the transmission of high intensities through optical fibers is being motivated by an increasing number of applications. Using different laser types and fiber materials, various studies are encountering transmission limitations due to laser-induced damage processes. For a number of years we have been investigating these limiting processes during the transmission of Q-switched, multimode, Nd:YAG laser pulses through step-index, multimode, fused-silica fiber. We have found that fiber transmission is often limited by a plasma-forming breakdown occurring at the fiber entrance face. This breakdown can result in subtle surface modifications that leave the entrance face more resistant to further breakdown or damage events. Catastrophic fiber damage can also occur as a result of a variety of mechanisms, with damage appearing at fiber entrance and exit faces, within the initial entry segment of the fiber path, and at other internal sites due to fiber fixturing and routing effects. System attributes that will affect breakdown and damage thresholds include laser characteristics, the design and alignment of laser-to-fiber injection optics, and fiber end-face preparation. In the present work we have combined insights gained in past studies in order to establish what thresholds can be achieved if all system attributes can be optimized to some degree. Our multimode laser utilized past modifications that produced a relatively smooth, quasi-Gaussian profile. The laser-to-fiber injection system achieved a relatively low value for the ratio of peak-to-average fluences at the fiber entrance face, incorporated a mode scrambler to generate a broad mode power distribution within the initial segment of the fiber path, and had improved fixturing to insure that the fiber axis was collinear with the incident laser beam. Test fibers were from a particular production lot for which initial-strength characteristics were established and a high-stress proof test was performed

  20. Multifuel multimodal network design; Projeto de redes multicombustiveis multimodal

    Energy Technology Data Exchange (ETDEWEB)

    Lage, Carolina; Dias, Gustavo; Bahiense, Laura; Ferreira Filho, Virgilio J.M. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia (COPPE). Programa de Engenharia de Producao

    2008-07-01

    The objective of the Multi commodity Multimodal Network Project is the development of modeling tools and methodologies for the optimal sizing of production networks and multimodal distribution of multiple fuel and its incomes, considering investments and transportation costs. Given the inherently non-linear combinatory nature of the problem, the resolution of real instances by the complete model, in an exact way, becomes computationally intractable. Thus, the strategy for resolution should contain a combination of exacts and heuristics methods, that must be applied to subdivisions of the original problem. This paper deals with one of these subdivisions, tackling the problem of modeling a network of pipelines in order to drain the production of ethanol away from the producing plants. The objective consists in defining the best network topology, minimizing investment and operational costs, and attending the total demand. In order to do that, the network was considered a tree, where the nodes are the center of producing regions and the edges are the pipelines, trough where the ethanol produced by plants must be drained away. The main objective also includes the decision over the optimal diameter of each pipeline and the optimal size of the bombs, in order to minimize the pumping costs. (author)

  1. Tube entrance lens focus control

    Science.gov (United States)

    Weisser, D. C.; Fifield, L. K.; Kitchen, T. F. G.; Tunningley, T. B.; Lobanov, N. R.; Muirhead, A. G.

    2013-02-01

    The entrance of the accelerator tube in a large electrostatic accelerator imposes a strong lens that dominates the beam optics. The magnification of the lens is large because of the low injection energy, the high voltage gradient of the acceleration tube and the long distance to the terminal. In the absence of the acceleration, the magnification would produce an unacceptably large beam spot at the terminal. The tyranny of the lens is especially irksome when the accelerator is required to operate at a lower terminal voltage than the one corresponding to the nominal gradient at high voltage. One way around the difficulty, used in NEC Pelletron accelerators, is to insert a series of nylon and steel rods that short together units of the acceleration structure at the terminal leaving the ones near the entrance close to the nominal gradient for optimum transmission. This operation takes time and risks the loss of insulating gas. Another alternative used in the 25URC at Oak Ridge National Laboratory, is to focus the beam at the tube entrance, substantially diluting the effect of the entrance lens. The beam then diverges and so requires an additional lens part way to the terminal. This solution is only partially effective and still necessitates use of shorting rods for low voltage operation. The fact that these elaborate strategies are used is evidence that the alternative of lowering the injection energy as the terminal voltage is lowered imposes enough problems that it is not used in practice. We have modeled a solution that controls the voltage gradient at the tube entrance using an external power supply. This not only maintains the focusing effect of the lens but provides the opportunity to tune the beam by adjusting the entrance lens. A 150 kV power supply outside the pressure vessel feeds a controllable voltage through a high voltage feed-through to the fifth electrode of the accelerator tube. Thus 150 kV on this electrode creates the nominal gradient of 30 kV per

  2. Metawidgets in the multimodal interface

    Energy Technology Data Exchange (ETDEWEB)

    Blattner, M.M. (Lawrence Livermore National Lab., CA (United States) Anderson (M.D.) Cancer Center, Houston, TX (United States)); Glinert, E.P.; Jorge, J.A.; Ormsby, G.R. (Rensselaer Polytechnic Inst., Troy, NY (United States). Dept. of Computer Science)

    1991-01-01

    We analyze two intertwined and fundamental issues concerning computer-to-human communication in the multimodal interfaces: the interplay between sound and graphics, and the role of object persistence. Our observations lead us to introduce metawidgets as abstract entities capable of manifesting themselves to users as image, as sound, or as various combinations and/or sequences of the two media. We show examples of metawidgets in action, and discuss mechanisms for choosing among alternative media for metawidget instantiation. Finally, we describe a couple of experimental microworlds we have implemented to test out some of our ideas. 17 refs., 7 figs.

  3. Ketamina en analgesia multimodal postcesarea

    OpenAIRE

    Monzón Rubio, Eva María

    2011-01-01

    Mediante la analgesia multimodal influimos en las diferentes vías del dolor a la vez que minimizamos los potenciales efectos adversos de los diferentes fármacos administrados. En el caso del dolor postcesárea esto adquiere un importante matiz debido a la necesidad de disminuir el uso de opioides que pasan a la leche materna en caso de lactancia natural. El uso de dosis subanestésicas de Ketamina ha demostrado en diferentes estudios la disminución de requerimientos de opioides en las primer...

  4. Activated Ras alters lens and corneal development through induction of distinct downstream targets

    Directory of Open Access Journals (Sweden)

    Reneker Lixing

    2010-01-01

    Full Text Available Abstract Background Mammalian Ras genes regulate diverse cellular processes including proliferation and differentiation and are frequently mutated in human cancers. Tumor development in response to Ras activation varies between different tissues and the molecular basis for these variations are poorly understood. The murine lens and cornea have a common embryonic origin and arise from adjacent regions of the surface ectoderm. Activation of the fibroblast growth factor (FGF signaling pathway induces the corneal epithelial cells to proliferate and the lens epithelial cells to exit the cell cycle. The molecular mechanisms that regulate the differential responses of these two related tissues have not been defined. We have generated transgenic mice that express a constitutively active version of human H-Ras in their lenses and corneas. Results Ras transgenic lenses and corneal epithelial cells showed increased proliferation with concomitant increases in cyclin D1 and D2 expression. This initial increase in proliferation is sustained in the cornea but not in the lens epithelial cells. Coincidentally, cdk inhibitors p27Kip1 and p57Kip2 were upregulated in the Ras transgenic lenses but not in the corneas. Phospho-Erk1 and Erk2 levels were elevated in the lens but not in the cornea and Spry 1 and Spry 2, negative regulators of Ras-Raf-Erk signaling, were upregulated more in the corneal than in the lens epithelial cells. Both lens and corneal differentiation programs were sensitive to Ras activation. Ras transgenic embryos showed a distinctive alteration in the architecture of the lens pit. Ras activation, though sufficient for upregulation of Prox1, a transcription factor critical for cell cycle exit and initiation of fiber differentiation, is not sufficient for induction of terminal fiber differentiation. Expression of Keratin 12, a marker of corneal epithelial differentiation, was reduced in the Ras transgenic corneas. Conclusions Collectively, these

  5. Vitreous Humor Changes Expression of Iron-Handling Proteins in Lens Epithelial Cells

    Science.gov (United States)

    Goralska, Malgorzata; Fleisher, Lloyd N.; McGahan, M. Christine

    2017-01-01

    Purpose In humans, vitrectomy is associated with development of nuclear cataracts. Iron catalyzes free radical formation causing oxidative damage, which is implicated in cataract formation. This study was designed to determine if vitreous humor, which can initiate differentiation of lens epithelial cells, would have an effect on iron-handling proteins. Methods Cultured canine lens epithelial cells were treated with collected canine vitreous humor. Lysates of treated and control cells were separated by SDS-PAGE. Ferritin H- and L-chains, transferrin receptor 1, and aquaporin 0 were immunodetected and quantitated with specific antibodies. Morphologic changes in treated cells were assessed. Results Treatment of lens epithelial cells with a 33% (vol/vol) solution of vitreous humor changed the morphology of lens cells and induced expression of aquaporin 0, a marker of fiber cell differentiation that was undetectable in control cells. Treatment did not modify the size of iron-handling proteins but significantly increased content of ferritin from 2.9- to 8.8-fold over control and decreased levels of transferrin receptor by 37% to 59%. Conclusions Vitreous humor may significantly limit iron uptake by transferrin/transferrin receptor pathway, and by increasing ferritin levels could profoundly increase the iron-storage capacity of ferritin in lens cells. Vitreous humor may play a significant protective role against iron-catalyzed oxidative damage of lens epithelial cells and therefore in the formation of cataracts. PMID:28245299

  6. Modern lens antennas for communications engineering

    CERN Document Server

    Thornton, John

    2012-01-01

    The aim of this book is to present the modern design principles and analysis of lens antennas. It gives graduates and RF/Microwave professionals the design insights in order to make full use of lens antennas.  Why do we want to write a book in lens antennas? Because this topic has not been thoroughly publicized, its importance is underestimated. As antennas play a key role in communication systems, recent development in wireless communications would indeed benefit from the characteristics of lens antennas: low profile, and low cost etc.  The major advantages of lens antennas are na

  7. Step-index optical fiber drawn from 3D printed preforms.

    Science.gov (United States)

    Cook, Kevin; Balle, Geoffrey; Canning, John; Chartier, Loïc; Athanaze, Tristan; Hossain, M A; Han, Chunyang; Comatti, Jade-Edouard; Luo, Yanhua; Peng, Gang-Ding

    2016-10-01

    Optical fiber is drawn from a dual-head 3D printer fabricated preform made of two optically transparent plastics with a high-index core (NA∼0.25, V>60). The asymmetry observed in the fiber arises from asymmetry in the 3D printing process. The highly multimode optical fiber has losses measured by cut-back as low as α∼0.44  dB/cm in the near IR.

  8. Multimodality Imaging for Interventional Cardiology.

    Science.gov (United States)

    Celi, Simona; Martini, Nicola; Pastormerlo, Luigi Emilio; Positano, Vincenzo; Berti, Sergio

    2017-01-01

    In the last decades, interventional cardiology has received fast and wide implementation as an effective alternative treatment to surgery for several congenital and acquired diseases. In this scenario, imaging provides solutions for most clinical needs, from diagnosis to prognosis and risk stratification, as well as anatomical and functional assessment. In this review article, we present recent innovations in medical imaging for structural heart disease and coronary artery disease, emphasizing the progress achieved in the field of multimodality imaging and the solutions proposed to some as-yet unresolved technical problems for safe and effective procedural performance. Intra-procedural guidance can be facilitated by established multimodality cardiac imaging such as transesophageal 2D and 3D echocardiography and by novel techniques as echo-fluoroscopy overlay and 3D modeling/printing. Computed tomography and magnetic resonance imaging are particularly helpful for preprocedural morphology assessment and device sizing. Successful planning, performance, and aftercare of interventions depend heavily on accurate imaging for both structural heart disease and coronary artery disease. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  9. Contact lens surface by electron beam

    International Nuclear Information System (INIS)

    Shin, Jung Hyuck; Lee, Suk Ju; Hwang, Kwang Ha; Jeon Jin

    2011-01-01

    Contact lens materials needs good biocompatibility, high refractive index, high optical transparency, high water content etc. Surface treat method by using plasma and radiation can modify the physical and/or chemical properties of the contact lens surface. Radiation technology such as electron beam irradiation can apply to polymerization reaction and enhance the functionality of the polymer.The purpose of this study is to modify of contact lens surface by using Eb irradiation technology. Electron beam was irradiated to the contact lens surface which was synthesized thermal polymerization method and commercial contact lens to modify physical and chemical properties. Ft-IR, XP, UV-vis spectrophotometer, water content, oxygen trans-metastability were used to characterize the surface state, physicochemical, and optical property of the contact lens treated with Eb. The water content and oxygen transmissibility of the contact lens treated with Eb were increased due to increase in the hydrophilic group such as O-C=O and OH group on the contact lens surface which could be produced by possible reaction between carbon and oxygen during the Eb irradiation. All of the lenses showed the high optical transmittance above 90%. In this case of B/Es, TES, Ti contact lens, the optical transmittance decreased about 5% with increasing Eb dose in the wavelength of UV-B region. The contact lens modified by Eb irradiation could improve the physical properties of the contact lens such as water content and oxygen transmissibility

  10. Lens decenter and tilt measurement by interferogram

    Science.gov (United States)

    Hung, Min-Wei; Wu, Wen-Hong; Huang, Kuo-Cheng

    2009-11-01

    For the recent years, the vigorous development of the electro-optic industry, particularly the digital camera and the cellular phone camera, has placed a larger and larger demand for the optical devices. Among the optical lens, the aspherical optical lens plays the key component because the aspherical lens may provide better imaging quality then the spherical lens does. For the manufacturing reason, the aspherical lens is prone to a decenter or tilt issue with respect to the optical axes of its two surfaces. To measure decenter and tile error specifically would help to obviate the deficient lens, but most of the present measuring method can't provide this function. This paper proposed a new method to specifically measure the decenter and tile of lens by observing the interferogram of each surface. And the corresponding measuring instrument, which contains interferometer and motion stages, was introduced as well.

  11. Angle-tip Fiber Probe as Humidity Sensor

    Directory of Open Access Journals (Sweden)

    Pabitra NATH

    2010-05-01

    Full Text Available In this paper, I present a simple fiber optic relative humidity sensor (FORHS using an angled-tip multimode optical fiber. The sensing region is fabricated by coating moisture sensitive Cobalt Chloride (CoCl2 doped polyvinyl alcohol (PVA film on the surface of fiber optic tip. Light signal introducing from flat-end of the fiber is back-reflected at the fiber tip-air interface by the effect of total internal refection. The change of relative humidity (RH in the outstanding medium affects of evanescent field absorption at the fiber tip-sensing film interface thus, modulates the back-reflected signal. With the present sensing investigation, RH ranging from 5 % to 95 % can be measured with high degree of repeatability and has a fast response time of about 2 seconds.

  12. Looking beyond the perfect lens

    International Nuclear Information System (INIS)

    Wee, W H; Pendry, J B

    2010-01-01

    The holy grail of imaging is the ability to see through anything. From the conservation of energy, we can easily see that to see through a lossy material would require lenses with gain. The aim of this paper therefore is to propose a simple scheme by which we can construct a general perfect lens, with gain-one that can restore both the phases and amplitudes of near and far fields.

  13. A Review Of Multimodal Biometric Authentication Systems

    Directory of Open Access Journals (Sweden)

    Kunal Kumar

    2015-08-01

    Full Text Available Authentication is the process of validating the identity of a person based on certain input that the person provides. Authentication has become a major topic of research due to the increasing number of attacks on computer networks around the globe. This review paper focuses on multimodal biometric authentication systems in use today. The aim is to elicit the best combination of authentication factors for multimodal use. We study the strengths and weakness of selected biometric mechanisms and recommend novel solutions to include in multimodal biometric systems to improve on the current biometric drawbacks. We believe this paper will provide security researchers some useful insight whilst designing better biometric systems.

  14. Mediating multimodal environmental knowledge across animation techniques

    DEFF Research Database (Denmark)

    Maier, Carmen Daniela

    2011-01-01

    in the technology- mediated discourse of short animation films. This is done by employing the model of multimodal discourse analysis proposed by Van Leeuwen (2008) and Machin and Van Leeuwen (2007) to the analysis of a series of animation films focused on environmental problems. These films are united under......://www.sustainlane.com/. The multimodal discourse analysis is meant to reveal how selection and representation of environmental knowledge about social actors, social actions, resources, time and space are influenced by animation techniques. Furthermore, in the context of this multimodal discourse analysis, their influence upon...

  15. Photonic Lantern Adaptive Spatial Mode Control in LMA Fiber Amplifiers using SPGD

    Science.gov (United States)

    2015-12-15

    Saval, T. A. Birks, J. Bland- Hawthorn , and M. Englund, "Multimode fiber devices with single-mode performance," Opt. Lett. 30, 2545-2547 (2005). 7. D...Noordegraaf, P. M. Skovgaard, M. D. Nielsen, and J. Bland- Hawthorn , "Efficient multi-mode to single-mode coupling in a photonic lantern," Opt...Express 17, 1988-1994 (2009). 8. S. G. Leon-Saval, A. Argyros, and J. Bland- Hawthorn , "Photonic lanterns: a study of light propagation in multimode to

  16. CONTACT LENS RELATED CORNEAL ULCER

    Directory of Open Access Journals (Sweden)

    AGARWAL P

    2010-01-01

    Full Text Available A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are:overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. The presenting symptoms of contact lens related corneal ulcers include eye discomfort, foreign body sensation and lacrimation. More serious symptoms are redness (especially circum-corneal injection, severe pain, photophobia, eye discharge and blurring of vision. The diagnosis is established by a thorough slit lamp microscopic examination with fluorescein staining and corneal scraping for Gram stain and culture of the infective organism. Delay in diagnosing and treatment can cause permanent blindness, therefore an early referral to ophthalmologist and commencing of antimicrobial therapy can prevent visual loss.

  17. Late capsular bag contraction and intraocular lens subluxation in retinitis pigmentosa: a case report

    Directory of Open Access Journals (Sweden)

    Tsai Frank F

    2011-02-01

    Full Text Available Abstract Introduction Retinitis pigmentosa is clinically characterized by loss of predominantly rod photoreceptor function as well as loss of peripheral vision. The classic clinical triad is considered to be the presence of bone spicule pigmentation in the peripheral retina, arteriolar attenuation, and waxy disc pallor. Cataracts, most commonly of the posterior subcapsular type, are often found in all forms of retinitis pigmentosa. Ectopia lentis and lens dislocation are known risk factors for those with retinitis pigmentosa, presumably secondary to zonular fiber weakness and vitreous degeneration. The post-operative complication of lens dislocation following cataract extraction in patients with retinitis pigmentosa has also been documented. Case presentation We report a case of severe capsular bag contraction with intraocular lens subluxation following cataract extraction in a 58-year-old Hispanic woman with retinitis pigmentosa. Conclusion Patients with retinitis pigmentosa undergoing cataract surgery should be notified of this potentially late complication of surgery.

  18. Dual-fiber OCT measurements

    Science.gov (United States)

    Elhady, Alaa; Sabry, Yasser M.; Yehia, Mohamed; Khalil, Diaa

    2014-03-01

    Conventional Optical Coherence Tomography (OCT) probes usually require complex optics at their tips for focusing the incident light on the measured samples and for scattered light collection. Such complexity is not compatible with the common-path OCT architecture, in which the reference arm is replaced by partial reflection from the probe fiber-air interface. This necessitates close proximity between the measured sample and the fiber tip to have sufficient measurement depth inside the sample within the coherence length of the light. Indeed, separating the light injection and collection paths simplifies the design of the OCT heads and allows the easy integration of a MEMS scanner within the head. In this work, we propose a new OCT probe configuration that allows for such separation. To this end, a swept source OCT setup was built using a tunable laser connected to the single-mode fiber of the probe and the scattered light from the measured sample was collected using another Multi-Mode Fiber (MMF). The usage of the MMF in the reception enables higher power-collection efficiency and transfers the reference position to be at the first layer of the sample under test, which further extends the maximum depth analyzed by the OCT system and overcomes the restriction of the close proximity mentioned above. This simple concept is validated by experimental measurements carried out on 1 mm-thick sheets of glasses with and without an integrated MEMS scanner on-chip.

  19. Multimodal integration in statistical learning

    DEFF Research Database (Denmark)

    Mitchell, Aaron; Christiansen, Morten Hyllekvist; Weiss, Dan

    2014-01-01

    Recent advances in the field of statistical learning have established that learners are able to track regularities of multimodal stimuli, yet it is unknown whether the statistical computations are performed on integrated representations or on separate, unimodal representations. In the present study......, we investigated the ability of adults to integrate audio and visual input during statistical learning. We presented learners with a speech stream synchronized with a video of a speaker’s face. In the critical condition, the visual (e.g., /gi/) and auditory (e.g., /mi/) signals were occasionally...... incongruent, which we predicted would produce the McGurk illusion, resulting in the perception of an audiovisual syllable (e.g., /ni/). In this way, we used the McGurk illusion to manipulate the underlying statistical structure of the speech streams, such that perception of these illusory syllables...

  20. Simplified Fiber-Wireless Distribution of HD Video in Passive and Active W-band Close Proximity Terminals

    DEFF Research Database (Denmark)

    Lebedev, Alexander; Rodes Lopez, Roberto; Yu, Xianbin

    2012-01-01

    We experimentally demonstrate uncompressed high-definition (HD) video distribution at 84 GHz Radio over Fiber link achieving up to 3 meters of wireless transmission. We experimentally emulate Metro-Access architecture by deploying single/multimode fibers. Passive and active approaches for remote ...

  1. Multispectral analysis of multimodal images

    International Nuclear Information System (INIS)

    Kvinnsland, Yngve; Brekke, Njaal; Taxt, Torfinn M.; Gruener, Renate

    2009-01-01

    An increasing number of multimodal images represent a valuable increase in available image information, but at the same time it complicates the extraction of diagnostic information across the images. Multispectral analysis (MSA) has the potential to simplify this problem substantially as unlimited number of images can be combined, and tissue properties across the images can be extracted automatically. Materials and methods. We have developed a software solution for MSA containing two algorithms for unsupervised classification, an EM-algorithm finding multinormal class descriptions and the k-means clustering algorithm, and two for supervised classification, a Bayesian classifier using multinormal class descriptions and a kNN-algorithm. The software has an efficient user interface for the creation and manipulation of class descriptions, and it has proper tools for displaying the results. Results. The software has been tested on different sets of images. One application is to segment cross-sectional images of brain tissue (T1- and T2-weighted MR images) into its main normal tissues and brain tumors. Another interesting set of images are the perfusion maps and diffusion maps, derived images from raw MR images. The software returns segmentation that seem to be sensible. Discussion. The MSA software appears to be a valuable tool for image analysis with multimodal images at hand. It readily gives a segmentation of image volumes that visually seems to be sensible. However, to really learn how to use MSA, it will be necessary to gain more insight into what tissues the different segments contain, and the upcoming work will therefore be focused on examining the tissues through for example histological sections

  2. Photonic lantern with cladding-removable fibers

    Science.gov (United States)

    Sun, Weimin; Yan, Qi; Bi, Yao; Yu, Haijiao; Liu, Xiaoqi; Xue, Jiuling; Tian, He; Liu, Yongjun

    2014-07-01

    Recently, spectral measurement becomes an important tool in astronomy to find exoplanets etc. The fibers are used to transfer light from the focal plate to spectrometers. To get high-resolution spectrum, the input slits of the spectrometers should be as narrow as possible. In opposite, the light spots from the fibers are circle, which diameters are clearly wider than the width of the spectrometer slits. To reduce the energy loss of the fiber-guide star light, many kinds of image slicers were designed and fabricated to transform light spot from circle to linear. Some different setup of fiber slicers are introduced by different research groups around the world. The photonic lanterns are candidates of fiber slicers. Photonic lantern includes three parts: inserted fibers, preform or tubing, taped part of the preform or tubing. Usually the optical fields concentrate in the former-core area, so the light spots are not uniform from the tapered end of the lantern. We designed, fabricated and tested a special kind of photonic lantern. The special fibers consist polymer cladding and doped high-index core. The polymer cladding could be easily removed using acetone bath, while the fiber core remains in good condition. We inserted the pure high-index cores into a pure silica tubing and tapered it. During the tapering process, the gaps between the inserted fibers disappeared. Finally we can get a uniform tapered multimode fiber end. The simulation results show that the longer the taper is, the lower the loss is. The shape of the taper should be controlled carefully. A large-zone moving-flame taper machine was fabricated to make the special photonic lantern. Three samples of photonic lanterns were fabricated and tested. The lanterns with cladding-removable fibers guide light uniform in the tapered ends that means these lanterns could collect more light from those ends.

  3. Multiple-mode reconfigurable electro-optic switching network for optical fiber sensor array

    Science.gov (United States)

    Chen, Ray T.; Wang, Michael R.; Jannson, Tomasz; Baumbick, Robert

    1991-01-01

    This paper reports the first switching network compatible with multimode fibers. A one-to-many cascaded reconfigurable interconnection was built. A thin glass substrate was used as the guiding medium which provides not only higher coupling efficiency from multimode fiber to waveguide but also better tolerance of phase-matching conditions. Involvement of a total-internal-reflection hologram and multimode waveguide eliminates interface problems between fibers and waveguides. The DCG polymer graft has proven to be reliable from -180 C to +200 C. Survivability of such an electrooptic system in harsh environments is further ensured. LiNbO3 was chosen as the E-O material because of its stability at high temperatures (phase-transition temperature of more than 1000 C) and maturity of E-O device technology. Further theoretical calculation was conducted to provide the optimal interaction length and device capacitance.

  4. Multimodal transportation best practices and model element.

    Science.gov (United States)

    2014-06-01

    This report provides guidance in developing a multimodal transportation element of a local government comprehensive : plan. Two model elements were developed to address differences in statutory requirements for communities of different : sizes and pl...

  5. Intelligent Multimodal Signal Adaptation System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Micro Analysis and Design (MA&D) is pleased to submit this proposal to design an Intelligent Multimodal Signal Adaptation System. This system will dynamically...

  6. Responsive Multimodal Transportation Management Strategies And IVHS

    Science.gov (United States)

    1995-02-01

    THE PURPOSE OF THIS STUDY WAS TO INVESTIGATE NEW AND INNOVATIVE WAYS TO INCORPORATE IVHS TECHNOLOGIES INTO MULTIMODAL TRANSPORTATION MANAGEMENT STRATEGIES. MUCH OF THE IVHS RESEARCH DONE TO DATE HAS ADDRESSED THE MODES INDIVIDUALLY. THIS PROJECT FOCU...

  7. Rotational inertia and multimodal heaviness perception.

    Science.gov (United States)

    Streit, Matthew; Shockley, Kevin; Riley, Michael A

    2007-10-01

    Perceived heaviness of wielded objects has been shown to be a function of the objects' rotational inertia--the objects' resistance to rotational acceleration. Studies have also demonstrated that if virtual objects rotate faster than the actual wielded object (i.e., a rotational gain is applied to virtual object motion), the wielded object is perceived as systematically lighter. The present research determined whether combining those inertial and visual manipulations would influence heaviness perception in a manner consistent with an inertial model of multimodal heaviness perception. Rotational inertia and optical rotational gain of wielded objects were manipulated to specify inertia multimodally. Both visual and haptic manipulations significantly influenced perceived heaviness. The results suggest that rotational inertia is detected multimodally and that multimodal heaviness perception conforms to an inertial model.

  8. Primary intraocular lens implantation for penetrating lens trauma in Africa.

    Science.gov (United States)

    Bowman, R J; Yorston, D; Wood, M; Gilbert, C; Foster, A

    1998-09-01

    This study aimed to audit the surgical strategy of primary posterior chamber intraocular lens implantation for cases of recent penetrating trauma involving the lens in an African population. Retrospective, noncomparative case series. Seventy-two cases are reported, including all patients who underwent primary intraocular lens implantation for traumatic cataract extraction performed within 1 month of injury between 1988 and 1996. Demographic characteristics and follow-up attendance rates are analyzed. Surgical technique and the occurrence of intraoperative and postoperative complications are reported. Visual outcomes are reported with detailed analysis for cases of poor visual outcome. Mean age was 14.3 years (standard deviation = 11.1), 57 (79%) were male and 15 (21%) were female (chi-square = 23.66, P capsule had been breached by the trauma in 27 (38%) cases, and 15 of these required anterior vitrectomy. Capsular fixation of the implant was achieved in 49% of patients, the remainder having sulcus fixation. Intraoperative rupture of the posterior capsule occurred in four cases. The only common postoperative complication was acute fibrinous anterior uveitis, which occurred in 29 (40%) patients, and 32% of patients followed up for at least 6 months required secondary posterior capsulotomy. This was more common in younger patients (chi-square = 4.2, P < 0.05). Corrected postoperative visual acuities were available for 51 patients, of which 71% achieved 20/60 or better visual acuity. Patients 6 years of age or younger were less likely to achieve 20/60 (chi-square = 6.61, P = 0.01). This surgical strategy has proved successful, producing good visual results and causing no sight-threatening complications. Primary posterior capsulotomy may be appropriate for younger patients.

  9. Realization of fiber optic displacement sensors

    Science.gov (United States)

    Guzowski, Bartlomiej; Lakomski, Mateusz

    2018-03-01

    Fiber optic sensors are very promising because of their inherent advantages such as very small size, hard environment tolerance and impact of electromagnetic fields. In this paper three different types of Intensity Fiber Optic Displacement Sensors (I-FODS) are presented. Three configurations of I-FODS were realized in two varieties. In the first one, the cleaved multimode optical fibers (MMF) were used to collect reflected light, while in the second variety the MMF ended with ball lenses were chosen. To ensure an accurate alignment of optical fibers in the sensor head the MTP C9730 optical fiber ferrules were used. In this paper the influence of distribution of transmitting and detecting optical fibers on sensitivity and linear range of operation of developed I-FODS were investigated. We have shown, that I-FODS with ball lenses receive average 10.5% more reflected power in comparison to the cleaved optical fibers and they increase linearity range of I-FODS by 33%. In this paper, an analysis of each type of the realized sensor and detailed discussion are given.

  10. Gadolinia nanofibers as a multimodal bioimaging and potential radiation therapy agent

    Directory of Open Access Journals (Sweden)

    A. M. Grishin

    2015-05-01

    Full Text Available Continuous bead-free C-type cubic gadolinium oxide (Gd2O3 nanofibers 20-30 μm long and 40-100 nm in diameter were sintered by sol-gel calcination assisted electrospinning technique. Dipole-dipole interaction of neighboring Gd3+ ions in nanofibers with large length-to-diameter aspect ratio results in some kind of superparamagnetic behavior: fibers are magnetized twice stronger than Gd2O3 powder. Being compared with commercial Gd-DTPA/Magnevist®, Gd2O3 diethyleneglycol-coated (Gd2O3-DEG fibers show high 1/T1 and 1/T2 proton relaxivities. Intense room temperature photoluminescence, high NMR relaxivity and high neutron scattering cross-section of 157Gd nucleus promise to integrate Gd2O3 fibers for multimodal bioimaging and neutron capture therapy.

  11. Treatment Approaches for Interstitial Cystitis: Multimodality Therapy

    Science.gov (United States)

    Evans, Robert J

    2002-01-01

    Interstitial cystitis is an increasingly common disease characterized by urgency, frequency, and pelvic pain. Its etiology is poorly understood but is likely to be multifactorial. A proposed pathophysiology describing a cascade of events, including epithelial dysfunction, mast cell activation, and neurogenic inflammation, is presented. Using this model, multimodality therapy regimens have been developed that treat all components of this cascade. Multimodality therapy appears more effective than single agents in the treatment of interstitial cystitis. PMID:16986029

  12. Quantifying Quality Aspects of Multimodal Interactive Systems

    CERN Document Server

    Kühnel, Christine

    2012-01-01

    This book systematically addresses the quantification of quality aspects of multimodal interactive systems. The conceptual structure is based on a schematic view on human-computer interaction where the user interacts with the system and perceives it via input and output interfaces. Thus, aspects of multimodal interaction are analyzed first, followed by a discussion of the evaluation of output and input and concluding with a view on the evaluation of a complete system.

  13. Multimodal character viewpoint in quoted dialogue sequences

    Directory of Open Access Journals (Sweden)

    Kashmiri Stec

    2017-05-01

    Full Text Available We investigate the multimodal production of character viewpoint in spoken American English narratives by performing complementary qualitative and quantitative analyses of two quoted dialogues, focusing on the storyteller’s use of character viewpoint gestures, character intonation, character facial expression, spatial orientation and gaze. A micro-analysis revealed that the extent of multimodal articulation depends on (i the quoted speaker, with different multimodal articulatory patterns found for quotes by the speaker’s past self vs. a third-person character, and (ii the position of the quoted utterance within the quoted dialogue, with mid-dialogue utterances garnering less co-articulation than initial or final utterances within the quoted dialogue. We further investigated these observations using a quantitative approach, which was based on 'generalized additive modeling' (GAM. The GAM analysis revealed different multimodal patterns for each quoted character, as indicated by the number of co-produced multimodal articulators. These patterns were found to hold regardless of the quote’s position within the narrative. We discuss these findings with respect to previous work on multimodal quotation. This article is part of the special collection: Perspective Taking

  14. Rapid prototype modeling in a multimodality world

    Science.gov (United States)

    Bidaut, Luc; Madewell, John; Yasko, Alan

    2006-03-01

    Introduction: Rapid prototype modeling (RPM) has been used in medicine principally for bones - that are easily extracted from CT data sets - for planning orthopaedic, plastic or maxillo-facial interventions, and/or for designing custom prostheses and implants. Based on newly available technology, highly valuable multimodality approaches can now be applied to RPM, particularly for complex musculo-skeletal (MSK) tumors where multimodality often transcends CT alone. Methods: CT data sets are acquired for primary evaluation of MSK tumors in parallel with other modalities (e.g., MR, PET, SPECT). In our approach, CT is first segmented to provide bony anatomy for RPM and all other data sets are then registered to the CT reference. Parametric information relevant to the tumor's characterization is then extracted from the multimodality space and merged with the CT anatomy to produce a hybrid RPM-ready model. This model - that also accommodates digital multimodality visualization - is then produced on the latest generation of 3D printers, which permits both shapes and colors. Results: Multimodality models of complex MSK tumors have been physically produced on modern RPM equipment. This new approach has been found to be a clear improvement over the previously disconnected physical RPM and digital multimodality visualization. Conclusions: New technical developments keep opening doors to sophisticated medical applications that can directly impact the quality of patient care. Although this early work still deals with bones as base models for RPM, its use to encompass soft tissues is already envisioned for future approaches.

  15. L-type calcium channels play a critical role in maintaining lens transparency by regulating phosphorylation of aquaporin-0 and myosin light chain and expression of connexins.

    Directory of Open Access Journals (Sweden)

    Rupalatha Maddala

    Full Text Available Homeostasis of intracellular calcium is crucial for lens cytoarchitecture and transparency, however, the identity of specific channel proteins regulating calcium influx within the lens is not completely understood. Here we examined the expression and distribution profiles of L-type calcium channels (LTCCs and explored their role in morphological integrity and transparency of the mouse lens, using cDNA microarray, RT-PCR, immunoblot, pharmacological inhibitors and immunofluorescence analyses. The results revealed that Ca (V 1.2 and 1.3 channels are expressed and distributed in both the epithelium and cortical fiber cells in mouse lens. Inhibition of LTCCs with felodipine or nifedipine induces progressive cortical cataract formation with time, in association with decreased lens weight in ex-vivo mouse lenses. Histological analyses of felodipine treated lenses revealed extensive disorganization and swelling of cortical fiber cells resembling the phenotype reported for altered aquaporin-0 activity without detectable cytotoxic effects. Analysis of both soluble and membrane rich fractions from felodipine treated lenses by SDS-PAGE in conjunction with mass spectrometry and immunoblot analyses revealed decreases in β-B1-crystallin, Hsp-90, spectrin and filensin. Significantly, loss of transparency in the felodipine treated lenses was preceded by an increase in aquaporin-0 serine-235 phosphorylation and levels of connexin-50, together with decreases in myosin light chain phosphorylation and the levels of 14-3-3ε, a phosphoprotein-binding regulatory protein. Felodipine treatment led to a significant increase in gene expression of connexin-50 and 46 in the mouse lens. Additionally, felodipine inhibition of LTCCs in primary cultures of mouse lens epithelial cells resulted in decreased intracellular calcium, and decreased actin stress fibers and myosin light chain phosphorylation, without detectable cytotoxic response. Taken together, these observations

  16. Research on one manual zoom liquid lens

    Science.gov (United States)

    Zhao, Cunhua; Shi, Yongpeng; Li, Wenjiao; Li, Congcong

    2011-11-01

    In liquid zoom lens, the accurate fixed-focus location needs the accurate calculation of focal length. That is to say, the accurate calculation of surface curvature must be obtained. Therefore, the research of their relation in liquid zoom lens becomes extremely important which has a directly theoretical instruction for the design of liquid zoom lenses. In our paper, the relation is studied. A manual liquid lens is reported which has upper and nether components with specificaton Φ12×5mm. The zoom lens is obtained by the upper component circumvolving down into the nether components.

  17. Numerical analyses of planer plasmonic focusing lens

    Science.gov (United States)

    Chou, Yen-Yu; Lee, Yeeu-Chang

    2018-03-01

    The use of polystyrene (PS) sphere lithography has been widely applied in the fabrication of micron and nano structures, due to their low cost and ease of fabrication in large scale applications. This study evaluated the feasibility of plasmonic lens base on metal thin films with nanohole structures fabricated by using PS sphere lithography through three-dimensional (3D) finite difference time domain (FDTD) method. We calculated the intensity profile of lens with various wavelength of incident light, lens size, cutting positions, diameters of nanohole, and periods of nanohole to investigate the geometric parameters influence on the focusing properties of the plasmonic lens.

  18. Exchange of tears under a contact lens is driven by distortions of the contact lens.

    Science.gov (United States)

    Maki, Kara L; Ross, David S

    2014-12-01

    We studied the flow of the post-lens tear film under a soft contact lens to understand how the design parameters of contact lenses can affect ocular health. When a soft contact lens is inserted, the blinking eyelid causes the lens to stretch in order to conform to the shape of the eye. The deformed contact lens acts to assume its un-deformed shape and thus generates a suction pressure in the post-lens tear film. In consequence, the post-lens tear fluid moves; it responds to the suction pressure. The suction pressure may draw in fresh fluid from the edge of the lens, or it may eject fluid there, as the lens reassumes its un-deformed shape. In this article, we develop a mathematical model of the flow of the post-lens tear fluid in response to the mechanical suction pressure of a deformed contact lens. We predict the amount of exchange of fluid exchange under a contact lens and we explore the influence of the eye's shape on the rate of exchange of fluid. © The Author 2014. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved. For permissions please email: journals.permissions@oup.com.

  19. Effects of hyperbaric oxygen on crystalline lens and retina in nicotine-exposed rats.

    Science.gov (United States)

    Ari, Seyhmus; Nergiz, Yusuf; Cingü, Abdullah Kürşat; Atay, Ahmet Engin; Sahin, Alparslan; Cinar, Yasin; Caca, Ihsan

    2013-03-01

    To determine histopathological changes on crystalline lens and retina of rats after subcutaneous injection of nicotine and to examine the effects of hyperbaric oxygen (HBO) on these changes related to nicotine exposure. Twenty-eight female Sprague-Dawley rats were enrolled in the study and the rats were divided into four equal sized groups randomly (Group N: the rats exposed only to nicotine, group HB: the rats received only HBO, group N+HB: the rats that underwent to nicotine injection and subsequently received HBO, group C: the control group that neither exposed to nicotine nor received HBO). The rats were sacrificed by decapitation method and all were enucleated immediately after scarification. Tissue samples from crystalline lens, lens capsule, and the retina from the right eyes of the rats were examined by light microscopy. While the histological appearances of the retina and the lens was similar in group HB, group N+HB, and the control group; group N showed some pathological changes like decrement in the retinal ganglion cell density, atrophy of the retinal nerve fiber layer, congestion of the vessels in the optic nerve head, thinning of the internal plexiform layer, thinning of the lens capsule, and transformation of the anterior subcapsular epithelium into squamous epithelia. Subcutaneous injection of nicotine was found to be related with some pathological changes in the retina and lens of the Sprague-Dawley rats. However HBO caused no significant negative effect. Furthermore, the histopathological changes related to nicotine exposure in the lens and retina of the rats recovered by the application of HBO.

  20. Regulation of gene expression by Pax6 in ocular cells: a case of tissue-preferred expression of crystallins in lens.

    Science.gov (United States)

    Cvekl, Ales; Yang, Ying; Chauhan, Bharesh K; Cveklova, Kveta

    2004-01-01

    Lens development is an excellent model for genetic and biochemical studies of embryonic induction, cell cycle regulation, cellular differentiation and signal transduction. Differentiation of lens is characterized by lens-preferred expression and accumulation of water-soluble proteins, crystallins. Crystallins are required for light transparency, refraction and maintenance of lens integrity. Here, we review mechanisms of lens-preferred expression of crystallin genes by employing synergism between developmentally regulated DNA-binding transcription factors: Pax6, c-Maf, MafA/L-Maf, MafB, NRL, Sox2, Sox1, RARbeta/RXRbeta, RORalpha, Prox1, Six3, gammaFBP-B and HSF2. These factors are differentially expressed in lens precursor cells, lens epithelium and primary and secondary lens fibers. They exert their function in combination with ubiquitously expressed factors (e.g. AP-1, CREB, pRb, TFIID and USF) and co-activators/chromatin remodeling proteins (e.g. ASC-2 and CBP/p300). A special function belongs to Pax6, a paired domain and homeodomain-containing protein, which is essential for lens formation. Pax6 is expressed in lens progenitor cells before the onset of crystallin expression and it serves as an important regulatory factor required for expression of c-Maf, MafA/L-Maf, Six3, Prox1 and retinoic acid signaling both in lens precursor cells and the developing lens. The roles of these factors are illustrated by promoter studies of mouse alphaA-, alphaB-, gammaF- and guinea pig zeta-crystallins. Pax6 forms functional complexes with a number of transcription factors including the retinoblastoma protein, pRb, MafA, Mitf and Sox2. We present novel data showing that pRb antagonizes Pax6-mediated activation of the alphaA-crystallin promoter likely by inhibiting binding of Pax6 to DNA.

  1. Next-generation, high-density, low-cost, multimode optical backplane interconnect

    Science.gov (United States)

    Childers, Darrell; Childers, Eric; Graham, Joe; Hughes, Mike

    2012-01-01

    This paper describes the development, termination and performance of next generation optical backplane interconnect components. This low cost, dense optical interconnect technology combined with recent advances in 10G/lane and beyond, miniature imbedded Tx/Rx devices is driving bandwidth density to unprecedented levels. A monolithic, multi-fiber ferule with integrated collimating lenses was designed with the same overall footprint as a traditional MT-type, multi-fiber rectangular ferrule. The new optical ferrule was designed with precision micro holes for alignment to the lens array allowing for incorporation of multiple rows of fibers into single ferrule unit. The design supports up to four rows with as many as 16 fibers per row for a total potential lane count of up to 64 within in a single ferrule. A low cost termination is achieved by securing precision-cleaved fiber arrays into the rear of the ferrule with a quick-cure, index matched, UV light activated epoxy. The elimination of a polished fiber array greatly reduces the cost and complexity associated with physical contact based multi-fiber interconnects. With the same overall footprint as an MT ferrule, the new, lens-based ferrule can be used in conjunction with MPO and other MT based connectors. However, by eliminating the need for physical contact via the use of collimated light beams, the connection force per ferrule required is greatly reduced, paving the way for high ferrule counts and mass insertion of dense optical backplanes. Mated pairs of the new ferrule were tested for insertion loss with the substitution method and all channels were <1dB.

  2. Two Fiber Optical Fiber Thermometry

    Science.gov (United States)

    Jones, Mathew R.; Farmer, Jeffery T.; Breeding, Shawn P.

    2000-01-01

    An optical fiber thermometer consists of an optical fiber whose sensing tip is given a metallic coating. The sensing tip of the fiber is essentially an isothermal cavity, so the emission from this cavity will be approximately equal to the emission from a blackbody. Temperature readings are obtained by measuring the spectral radiative heat flux at the end of the fiber at two wavelengths. The ratio of these measurements and Planck's Law are used to infer the temperature at the sensing tip. Optical fiber thermometers have high accuracy, excellent long-term stability and are immune to electromagnetic interference. In addition, they can be operated for extended periods without requiring re-calibration. For these reasons. it is desirable to use optical fiber thermometers in environments such as the International Space Station. However, it has recently been shown that temperature readings are corrupted by emission from the fiber when extended portions of the probe are exposed to elevated temperatures. This paper will describe several ways in which the reading from a second fiber can be used to correct the corrupted temperature measurements. The accuracy and sensitivity to measurement uncertainty will be presented for each method.

  3. OM4 bend insensitive multi-mode fibers’ usefulness for MCM integration

    International Nuclear Information System (INIS)

    Guzowski, Bartłomiej; Lisik, Zbigniew; Tosik, Grzegorz; Ciupa, Emilia

    2012-01-01

    Highlights: ► The influence of high temperature exposure on OM4 fibers’ mechanical properties. ► Researching OM4 class fibers for use in innovative Optical Multi Chip Module. ► The influence of bending at a very small radius, up to 2 mm, on MM fibers. - Abstract: For future generations of electronic systems, a severe bottleneck is expected on the interconnection level and the use of optical interconnection is considered as one of the most promising solutions in this matter. Recent progress in fiber development resulted in new generation of optical fibers that are bend insensitive. This makes them ideal for Multi Chip Module (MCM) application. This paper focuses on OM4 bend insensitive multi-mode fibers’ usefulness for MCM integration, particularly the investigation of MM fiber loss is presented, which is influenced by bend diameter and the fiber's mechanical performance under influence of high temperature (400 °C–1000 °C adequate to MCM production process).

  4. [Acanthamoeba isolation from contact lens solution of contact lens wearers without keratitis].

    Science.gov (United States)

    Watanabe, R; Ishibashi, Y; Hommura, S; Ishii, K

    1994-05-01

    Acanthamoeba keratitis seems to be associated with wearing contact lenses. As controls, we surveyed contact lens wearers without keratitis. Contact lens solutions of 93 persons were examined in order to identify risk factors for contamination by Acanthamoeba. Therefore, the contact lens disinfection system and storage schedules were studied in each case. Acanthamoeba organisms were isolated from 4 specimens (4.3%). The incidence of Acanthamoeba was higher in specimens of soft contact lens solution than in those of hard contact lens solution, and all the Acanthamoeba positive cases had been using tap water.

  5. Primary anterior chamber intraocular lens for the treatment of severe crystalline lens subluxation.

    Science.gov (United States)

    Hoffman, Richard S; Fine, I Howard; Packer, Mark

    2009-10-01

    Subluxated cataractous and clear lenses are commonly treated by limbal or pars plana lensectomy followed by primary or secondary intraocular lens (IOL) implantation. Adjunctive capsular prosthetic devices have facilitated lens removal and IOL centration in these challenging cases but have also added complexity and potential complications to the procedure. Although crystalline lens extraction may be required to clear the visual axis in mild to moderate lens subluxations, we propose insertion of a primary anterior chamber IOL without lens extraction in severe subluxations when the eye is optically aphakic or can be made functionally aphakic following neodymium:YAG laser zonulysis. Two cases demonstrating this approach are presented.

  6. Multimodal Imaging Measures Predict Rearrest

    Directory of Open Access Journals (Sweden)

    Vaughn R Steele

    2015-08-01

    Full Text Available Rearrest has been predicted by hemodynamic activity in the anterior cingulate cortex (ACC during error-processing (Aharoni et al., 2013. Here we evaluate the predictive power after adding an additional imaging modality in a subsample of 45 incarcerated males from Aharoni et al. Event-related potentials (ERPs and hemodynamic activity were collected during a Go/NoGo response inhibition task. Neural measures of error-processing were obtained from the ACC and two ERP components, the error-related negativity (ERN/Ne and the error positivity (Pe. Measures from the Pe and ACC differentiated individuals who were and were not subsequently rearrested. Cox regression, logistic regression, and support vector machine (SVM neuroprediction models were calculated. Each of these models proved successful in predicting rearrest and SVM provided the strongest results. Multimodal neuroprediction SVM models with out of sample cross-validating accurately predicted rearrest (83.33%. Offenders with increased Pe amplitude and decreased ACC activation, suggesting abnormal error-processing, were at greatest risk of rearrest.

  7. Time-dependent multimode structure

    International Nuclear Information System (INIS)

    Edgu, E.

    1991-01-01

    In a previous paper, the authors sought to display the multimode kinetics structure and step changes were considered. In this paper, a similar study is undertaken in which ramp changes are considered. Throughout the previous study, a rather simple model of a bare, cylindrical, initially critical nuclear system was the focus. This system had a central region into which a control rod was suddenly inserted, or from which a control rod was suddenly ejected. (A rod follower concept was then adopted.) The mentioned transients were modeled by a two-mode synthesis approach that displayed, rather rigorously, the space-dependency behavior of the time- and space-dependent flux in question. It is useful to complete the picture previously drawn by a study within the authors' framework, where time-dependent changes now take place instead of step changes. In this paper, they consider a ramp rod drop in a bare cylindrical nuclear system as well as a ramp rod ejection from this system (still with a rod follower concept). The effect of a feedback mechanism is not taken into account

  8. Multimodal analgesia and regional anaesthesia.

    Science.gov (United States)

    Tornero Tornero, C; Fernández Rodríguez, L E; Orduña Valls, J

    Multimodal analgesia provides quality analgesia, with fewer side effects due to the use of combined analgesics or analgesic techniques. Regional anaesthesia plays a fundamental role in achieving this goal. The different techniques of regional anaesthesia that include both peripheral and central blocks in either a single dose or in continuous infusion help to modulate the nociceptive stimuli that access the central level. The emergence of the ultrasound as an effective system to perform regional anaesthesia techniques has allowed the development of new regional anaesthesia techniques that formerly could not be carried out since only neurostimulation or skin references were used. It is essential to take into account that even with effective blocking it is advisable to associate other drugs by other routes, in this way we will be able to reduce the required doses individually and attempt to achieve a synergistic, not purely additive, effect. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Protection of the eye lens

    International Nuclear Information System (INIS)

    2015-01-01

    The limit of radiation exposure for eye lens is going to decrease dramatically from 150 to 20 mSv as a transposition into the French law of a CIPR (International Commission for Radiation Protection) directive. Sanitary studies have shown that radiologists are more likely by a factor of 3.8 to get eye lens opacities than the rest of the population. The wearing of protective glasses is recommended and in order to get a better monitoring of the radiation dose new dosimeters have been designed, they can be worn on the glass frame of directly stuck on the skin near the eyes. A study has shown that veterinary surgeons that are accustomed to stay near animals to keep them quiet during radiological exams are prone to receive high doses as well as physicians that use hypnosis to decrease the level of anxiety of their patients during radiological exams. Radiation exposure of radiologists can be mitigated through: the use of protective shields and equipment and the optimization of the dose delivered to the patient. (A.C.)

  10. Highly Sensitive Liquid Core Temperature Sensor Based on Multimode Interference Effects

    Directory of Open Access Journals (Sweden)

    Miguel A. Fuentes-Fuentes

    2015-10-01

    Full Text Available A novel fiber optic temperature sensor based on a liquid-core multimode interference device is demonstrated. The advantage of such structure is that the thermo-optic coefficient (TOC of the liquid is at least one order of magnitude larger than that of silica and this, combined with the fact that the TOC of silica and the liquid have opposite signs, provides a liquid-core multimode fiber (MMF highly sensitive to temperature. Since the refractive index of the liquid can be easily modified, this allows us to control the modal properties of the liquid-core MMF at will and the sensor sensitivity can be easily tuned by selecting the refractive index of the liquid in the core of the device. The maximum sensitivity measured in our experiments is 20 nm/°C in the low-temperature regime up to 60 °C. To the best of our knowledge, to date, this is the largest sensitivity reported for fiber-based MMI temperature sensors.

  11. Color corrected Fresnel lens for solar concentration

    International Nuclear Information System (INIS)

    Kritchman, E.M.

    1979-01-01

    A new linear convex Fresnel lens with its groove side down is described. The design philosophy is similar to the highly concentrating two focal Fresnel lens but including a correction for chromatic aberration. A solar concentration ratio as high as 80 is achieved. For wide acceptance angles the concentration nears the theoretical maximum. (author)

  12. Modified suturing contact lens for penetrating keratoplasty.

    Science.gov (United States)

    Kramer, S G; Stewart, H L

    1978-11-01

    The authors have previously described a suturing contact lens that protects the corneal endothelium by aiding in the maintenance of the anterior chamber during penetrating keratoplasty. This report describes structural modifications of the suturing contact lens, which improve its stability and effectiveness. An additional configuration for use in corneal lacerations is presented.

  13. Charged black lens in de Sitter space

    Science.gov (United States)

    Tomizawa, Shinya

    2018-02-01

    We obtain a charged black lens solution in the five-dimensional Einstein-Maxwell-Chern-Simons theory with a positive cosmological constant. It is shown that the solution obtained here describes the formation of a black hole with the spatial cross section of a sphere from that of the lens space of L (n ,1 ) in five-dimensional de Sitter space.

  14. Contact Lens Use in the Civil Airman Population

    National Research Council Canada - National Science Library

    Nakagawara, Van

    2002-01-01

    ...) aeromedical certificate. Although contact lens technology has advanced dramatically in recent years, the aviation environment may still have adverse effects on contact lens performance in some flight situations...

  15. FIBER OPTICS, HOLOGRAPHY, AND OPTICAL DATA PROCESSING: Phase-conjugation suppression of the phase noise during propagation of giant laser pulses in an optical fiber

    Science.gov (United States)

    Belous, A. I.; Grigoruk, V. I.; Pasechnyĭ, V. A.; Strizhevskiĭ, V. L.; Chernyshov, V. A.

    1988-01-01

    An experimental study was made of the suppression of phase noise during propagation of giant ruby laser pulses in short (up to 0.1 m) multimode fiber waveguides. A segment of a fiber waveguide, in which stimulated Brillouin scattering took place, acted as a mirror performing phase conjugation. The dependences of the parameters of the corrected signal on the lengths of both waveguide segments were determined.

  16. Corrected electrostatic lens systems for ion beams

    International Nuclear Information System (INIS)

    Dalgish, R.L.

    1981-01-01

    Recent work in our laboratory has introduced a new class of electrostatic focus forming element for beams, the ELCO lens. It compares favourably with the electrostatic and magnetic quadrupole elements conventionally used for microbeam formation. The ELCO lens does however have disadvantages associated with apertures and alignment. We have continued with the development of ion beam lenses and have evolved a further class of lens element which eliminates aperture and alignment problems. This new element can be combined like optical lenses into an aberration corrected system. Experimental measurement on the basic lens element has confirmed mathematical analysis of ion trajectories through the element. This mathematical analysis predicts that the basic element can be combined into a corrected lens system for, either: (1) high resolution microprobe formation with intrinsic rastering ability, the spot size limited only by the beam properties; or (2) high quality image formation with large magnification/demagnification ratio and wide angular aperture. (orig.)

  17. Multimodal Similarity Gaussian Process Latent Variable Model.

    Science.gov (United States)

    Song, Guoli; Wang, Shuhui; Huang, Qingming; Tian, Qi

    2017-09-01

    Data from real applications involve multiple modalities representing content with the same semantics from complementary aspects. However, relations among heterogeneous modalities are simply treated as observation-to-fit by existing work, and the parameterized modality specific mapping functions lack flexibility in directly adapting to the content divergence and semantic complicacy in multimodal data. In this paper, we build our work based on the Gaussian process latent variable model (GPLVM) to learn the non-parametric mapping functions and transform heterogeneous modalities into a shared latent space. We propose multimodal Similarity Gaussian Process latent variable model (m-SimGP), which learns the mapping functions between the intra-modal similarities and latent representation. We further propose multimodal distance-preserved similarity GPLVM (m-DSimGP) to preserve the intra-modal global similarity structure, and multimodal regularized similarity GPLVM (m-RSimGP) by encouraging similar/dissimilar points to be similar/dissimilar in the latent space. We propose m-DRSimGP, which combines the distance preservation in m-DSimGP and semantic preservation in m-RSimGP to learn the latent representation. The overall objective functions of the four models are solved by simple and scalable gradient decent techniques. They can be applied to various tasks to discover the nonlinear correlations and to obtain the comparable low-dimensional representation for heterogeneous modalities. On five widely used real-world data sets, our approaches outperform existing models on cross-modal content retrieval and multimodal classification.

  18. Polarization Characterization of a Multi-Moded Feed Structure

    Data.gov (United States)

    National Aeronautics and Space Administration — The Polarization Characterization of a Multi-Moded Feed Structure projects characterize the polarization response of a multi-moded feed horn as an innovative...

  19. Rotational multiphoton endoscopy with a 1 microm fiber laser system.

    Science.gov (United States)

    Liu, Gangjun; Xie, Tuqiang; Tomov, Ivan V; Su, Jianping; Yu, Lingfeng; Zhang, Jun; Tromberg, Bruce J; Chen, Zhongping

    2009-08-01

    We present multiphoton microendoscopy with a rotational probe and a 1 microm fiber-based femtosecond laser. The rotational probe is based on a double-clad photonic crystal fiber, a gradient index lens, a microprism, and a rotational microelectronicmechanical system (MEMS) motor. The MEMS motor has a diameter of 2.2 mm and can provide 360 degrees full-view rotation. The fiber laser provides ultrashort pulses with a central wavelength at 1.034 microm and a repetition rate of 50 MHz. Second-harmonic-generation images of rat-tail tendon and fish scale are demonstrated with the rotational probe-based multiphoton system.

  20. Spatial beam shaping using a micro-structured optical fiber and all-fiber laser amplification system for large-scale laser facilities seeding

    International Nuclear Information System (INIS)

    Calvet, Pierre

    2014-01-01

    Spatial beam shaping is an important topic for the lasers applications. For various industrial areas (marking, drilling, laser-matter interaction, high-power laser seeding...) the optical beam has to be flattened. Currently, the state of the art of the beam shaping: 'free-space' solutions or highly multimode fibers, are not fully suitable. The first ones are very sensitive to any perturbations and the maintenance is challenging, the second ones cannot deliver a coherent beam. For this reason, we present in this manuscript a micro-structured optical single-mode fiber delivering a spatially flattened beam. This 'Top-Hat' fiber can shape any beam in a spatially coherent beam what is a progress with respect to the highly multimode fibers used in the state of the art. The optical fibers are easy to use and very robust, what is a strong benefit with respect to the 'free-space' solutions. Thanks to this fiber, we could realize an all-fiber multi-stage laser chain to amplify a 10 ns pulse to 100 μJ. Moreover the temporal, spectral and spatial properties were preserved. We adapted this 'Top-Hat' fiber to this multi-stage laser chain, we proved the capability and the interest of this fiber for the spatial beam shaping of the laser beams in highly performing and robust laser systems. (author) [fr

  1. Multimodale trafiknet i GIS (Multimodal Traffic Network in GIS)

    DEFF Research Database (Denmark)

    Kronbak, Jacob; Brems, Camilla Riff

    1996-01-01

    The report introduces the use of multi-modal traffic networks within a geographical Information System (GIS). The necessary theory of modelling multi-modal traffic network is reviewed and applied to the ARC/INFO GIS by an explorative example.......The report introduces the use of multi-modal traffic networks within a geographical Information System (GIS). The necessary theory of modelling multi-modal traffic network is reviewed and applied to the ARC/INFO GIS by an explorative example....

  2. Compound parabolic concentrator optical fiber tip for FRET-based fluorescent sensors

    DEFF Research Database (Denmark)

    Hassan, Hafeez Ul; Nielsen, Kristian; Aasmul, Soren

    2015-01-01

    polymer optical fiber for an excitation and emission wavelength of 550 nm and 650nm, respectively. The model suggests an increase of a factor of 1.6 to 4 in the collected fluorescent power for an ideal CPC tip, as compared to the plane-cut fiber tip for fiber lengths between 5 and 45mm......The Compound Parabolic Concentrator (CPC) optical fiber tip shape has been proposed for intensity based fluorescent sensors working on the principle of FRET (Förster Resonance Energy Transfer). A simple numerical Zemax model has been used to optimize the CPC tip geometry for a step-index multimode...

  3. Interferometric microstructured polymer optical fiber ultrasound sensor for optoacoustic endoscopic imaging in biomedical applications

    DEFF Research Database (Denmark)

    Gallego, Daniel; Sáez-Rodríguez, David; Webb, David

    2014-01-01

    to conventional piezoelectric transducers. These kind of sensors, made of biocompatible polymers, are good candidates for the sensing element in an optoacoustic endoscope because of its high sensitivity, its shape and its non-brittle and non-electric nature. The acoustic sensitivity of the intrinsic fiber optic...... interferometric sensors depends strongly of the material which is composed of. In this work we compare experimentally the intrinsic ultrasonic sensitivities of a PMMA mPOF with other three optical fibers: a singlemode silica optical fiber, a single-mode polymer optical fiber and a multimode graded...

  4. Investigation of lens morphology and mechanical characteristics of lens capsule and lens nucleus in patients with agerelated and diabetic cataract

    Directory of Open Access Journals (Sweden)

    A. S. Tishkova

    2014-07-01

    Full Text Available Purpose: To investigate the influence of carbohydrate metabolism on the structure and mechanical properties of the lens capsule and nucleus.Methods: Human lens pathology was studied in different forms of cataract. 220 patients with a cataract (220 eyes were included in this study. Morphological, immunohystological and immunocytochemical investigations of lens substance (antibodies to a- (a-А and a-В, b-, g- crystallines, spectroscopic analyses of smears and morphometric analyses of slices, investigation of lens morphology and mechanical caracteristics of lens capsule and lens nucleus were performed.Results: The capsule of the lens in patients with senile cataract contains more Na+, Cl-. The capsule of the lens in patients with senile cataract contains more Ca2+, O. Mechanical strength of the capsule in the case of diabetes mellitus was lower comparatively with senile cataract in the same age groups. More significant expression of a-В and b-crystallines was found in patients with diabetes mellitus comparatively with patients with age-related cataract. Morphological features were founded in patients with cortical and nuclear forms of senile cataract and the diabetic cataract.Conclusion: During surgery (ultrasonic microcoaxial phacoemulsification the equivalent of ultrasound was recorded. Lower density of the lens nucleus of patients with diabetes mellitus made it possible to use lower energy parameters. Using the torsion ultrasound in those cases allowed us to decrease the influence of ultrasound on eye tissues and reduce the time of achieving the maximum BCVA in the postsurgical period.

  5. Investigation of lens morphology and mechanical characteristics of lens capsule and lens nucleus in patients with agerelated and diabetic cataract

    Directory of Open Access Journals (Sweden)

    A. S. Tishkova

    2013-01-01

    Full Text Available Purpose: To investigate the influence of carbohydrate metabolism on the structure and mechanical properties of the lens capsule and nucleus.Methods: Human lens pathology was studied in different forms of cataract. 220 patients with a cataract (220 eyes were included in this study. Morphological, immunohystological and immunocytochemical investigations of lens substance (antibodies to a- (a-А and a-В, b-, g- crystallines, spectroscopic analyses of smears and morphometric analyses of slices, investigation of lens morphology and mechanical caracteristics of lens capsule and lens nucleus were performed.Results: The capsule of the lens in patients with senile cataract contains more Na+, Cl-. The capsule of the lens in patients with senile cataract contains more Ca2+, O. Mechanical strength of the capsule in the case of diabetes mellitus was lower comparatively with senile cataract in the same age groups. More significant expression of a-В and b-crystallines was found in patients with diabetes mellitus comparatively with patients with age-related cataract. Morphological features were founded in patients with cortical and nuclear forms of senile cataract and the diabetic cataract.Conclusion: During surgery (ultrasonic microcoaxial phacoemulsification the equivalent of ultrasound was recorded. Lower density of the lens nucleus of patients with diabetes mellitus made it possible to use lower energy parameters. Using the torsion ultrasound in those cases allowed us to decrease the influence of ultrasound on eye tissues and reduce the time of achieving the maximum BCVA in the postsurgical period.

  6. Instrumentation challenges in multi-modality imaging

    International Nuclear Information System (INIS)

    Brasse, D.; Boisson, F.

    2016-01-01

    Based on different physical principles, imaging procedures currently used in both clinical and preclinical applications present different performance that allow researchers to achieve a large number of studies. However, the relevance of obtaining a maximum of information relating to the same subject is undeniable. The last two decades have thus seen the advent of a full-fledged research axis, the multimodal in vivo imaging. Whether from an instrumentation point of view, for medical research or the development of new probes, all these research works illustrate the growing interest of the scientific community for multimodal imaging, which can be approached with different backgrounds and perspectives from engineers to end-users point of views. In the present review, we discuss the multimodal imaging concept, which focuses not only on PET/CT and PET/MRI instrumentation but also on recent investigations of what could become a possible future in the field.

  7. An Overview of Multimodal Neuroimaging Using Nanoprobes

    Directory of Open Access Journals (Sweden)

    Sriram Sridhar

    2017-02-01

    Full Text Available Nanomaterials have gained tremendous significance as contrast agents for both anatomical and functional preclinical bio-imaging. Contrary to conventional medical practices, molecular imaging plays an important role in exploring the affected cells, thus providing precision medical solutions. It has been observed that incorporating nanoprobes improves the overall efficacy of the diagnosis and treatment processes. These nano-agents and tracers are therefore often incorporated into preclinical therapeutic and diagnostic applications. Multimodal imaging approaches are well equipped with nanoprobes to explore neurological disorders, as they can display more than one type of characteristic in molecular imaging. Multimodal imaging systems are explored by researchers as they can provide both anatomical and functional details of tumors and affected tissues. In this review, we present the state-of-the-art research concerning multimodal imaging systems and nanoprobes for neuroimaging applications.

  8. Video genre classification using multimodal features

    Science.gov (United States)

    Jin, Sung Ho; Bae, Tae Meon; Choo, Jin Ho; Ro, Yong Man

    2003-12-01

    We propose a video genre classification method using multimodal features. The proposed method is applied for the preprocessing of automatic video summarization or the retrieval and classification of broadcasting video contents. Through a statistical analysis of low-level and middle-level audio-visual features in video, the proposed method can achieve good performance in classifying several broadcasting genres such as cartoon, drama, music video, news, and sports. In this paper, we adopt MPEG-7 audio-visual descriptors as multimodal features of video contents and evaluate the performance of the classification by feeding the features into a decision tree-based classifier which is trained by CART. The experimental results show that the proposed method can recognize several broadcasting video genres with a high accuracy and the classification performance with multimodal features is superior to the one with unimodal features in the genre classification.

  9. Multimodal imaging of cutaneous wound tissue

    Science.gov (United States)

    Zhang, Shiwu; Gnyawali, Surya; Huang, Jiwei; Ren, Wenqi; Gordillo, Gayle; Sen, Chandan K.; Xu, Ronald

    2015-01-01

    Quantitative assessment of wound tissue ischemia, perfusion, and inflammation provides critical information for appropriate detection, staging, and treatment of chronic wounds. However, few methods are available for simultaneous assessment of these tissue parameters in a noninvasive and quantitative fashion. We integrated hyperspectral, laser speckle, and thermographic imaging modalities in a single-experimental setup for multimodal assessment of tissue oxygenation, perfusion, and inflammation characteristics. Algorithms were developed for appropriate coregistration between wound images acquired by different imaging modalities at different times. The multimodal wound imaging system was validated in an occlusion experiment, where oxygenation and perfusion maps of a healthy subject's upper extremity were continuously monitored during a postocclusive reactive hyperemia procedure and compared with standard measurements. The system was also tested in a clinical trial where a wound of three millimeters in diameter was introduced on a healthy subject's lower extremity and the healing process was continuously monitored. Our in vivo experiments demonstrated the clinical feasibility of multimodal cutaneous wound imaging.

  10. River multimodal scenario for rehabilitation robotics.

    Science.gov (United States)

    Munih, Marko; Novak, Domen; Milavec, Maja; Ziherl, Jaka; Olenšek, Andrej; Mihelj, Matjaž

    2011-01-01

    This paper presents the novel "River" multimodal rehabilitation robotics scenario that includes video, audio and haptic modalities. Elements contributing to intrinsic motivation are carefully joined in the three modalities to increase motivation of the user. The user first needs to perform a motor action, then receives a cognitive challenge that is solved with adequate motor activity. Audio includes environmental sounds, music and spoken instructions or encouraging statements. Sounds and music were classified according to the arousal-valence space. The haptic modality can provide catching, grasping, tunnel or adaptive assistance, all depending on the user's needs. The scenario was evaluated in 16 stroke users, who responded to it favourably according to the Intrinsic Motivation Inventory questionnaire. Additionally, the river multimodal environment seems to elicit higher motivation than a simpler apple pick-and-place multimodal task. © 2011 IEEE

  11. Cuba Through A New Lens

    Directory of Open Access Journals (Sweden)

    Jean Stubbs

    2008-12-01

    Full Text Available [First paragraph] The Origins of the Cuban Revolution Reconsidered. Samuel Farber. Chapel Hill: University of North Carolina Press, 2006. x + 212 pp. (Paper US$ 19.95 Cuba: A New History. Ric hard Gott . New Haven: Yale University Press, 2005. xii + 384 pp. (Paper US$ 17.00 Havana: The Making of Cuban Culture. Antoni Kapcia. Oxford: Berg Publishers, 2005. xx + 236 pp. (Paper US$ 24.95 Richard Gott, Antoni Kapcia, and Samuel Farber each approach Cuba through a new lens. Gott does so by providing a broad-sweep history of Cuba, which is epic in scope, attaches importance to social as much as political and economic history, and blends scholarship with flair. Kapcia homes in on Havana as the locus for Cuban culture, whereby cultural history becomes the trope for exploring not only the city but also Cuban national identity. Farber revisits his own and others’ interpretations of the origins of the Cuban Revolution.

  12. Radiation studies in Lens culinaris

    International Nuclear Information System (INIS)

    Sinha, S.S.N.

    1977-01-01

    Estimation of chromosomal aberrations in flowers of Lens culinaris according to their sequence of development in the plants at 4, 8 and 12 Kr in the M 1 generation, showed that the later formed flowers had smaller percentages of cells with aberrations than those developed earlier. It is suggested that this may be the result of competition between more damaged and less damaged cells during the development of the shoot. There is consequently a decrease of sterility in successive flowers. The numbers of karyotypes taking part in the formation of lower and uppermost flowers were estimated cytologically at 4, 8 and 12 Kr. It was found that more karyotypes were involved in the formation of the lower flowers than in the upper ones. It appeared that at lower doses larger numbers of karyotypes were taking part in the formation of the chimaera than at higher doses. (auth.)

  13. Multimodality and children's participation in classrooms: Instances of ...

    African Journals Online (AJOL)

    It outlines the theoretical framework supporting the pedagogical approach, that of multimodal social semiotics, known more widely as “multimodality”, and discusses three instances of children's multimodal practice, in Grades 1 and 2, 7 and 10 respectively. It sums up the role played by multimodality in participation, showing ...

  14. Reference Resolution in Multi-modal Interaction: Position paper

    NARCIS (Netherlands)

    Fernando, T.; Nijholt, Antinus

    2002-01-01

    In this position paper we present our research on multimodal interaction in and with virtual environments. The aim of this presentation is to emphasize the necessity to spend more research on reference resolution in multimodal contexts. In multi-modal interaction the human conversational partner can

  15. Microbial contamination of contact lens storage cases and domestic tap water of contact lens wearers.

    Science.gov (United States)

    Üstüntürk, Miray; Zeybek, Zuhal

    2012-11-01

    Contact lenses have been widely used as an alternative to spectacles both in developed and developing countries. However, under certain circumstances, adverse responses can occur during contact lens wear and several microorganisms--including bacteria, fungi, and free living amoebae--can cause several eye infections in wearers. Extended wear of contact lenses is the major risk factor of eye infections such as microbial keratitis, besides contaminated contact lens storage case, contaminated lens care solutions, and inaccurate contact lens handling. In this study, we collected contact lens storage case and domestic tap water samples from 50 asymptomatic contact lens wearers. We determined that total aerobic mesophilic bacteria were isolated in 45 (90 %), Gram negative rod bacteria were isolated in 20 (40 %), Pseudomonas spp. were isolated in 2 (4 %) and fungi were isolated in 18 (36 %) out of 50 contact lens storage cases. Free living amoebae were not detected in investigated contact lens storage cases. At the same time, out of 50, total aerobic mesophilic bacteria were isolated in 34 (68 %), fungi were isolated in 15 (30 %) and free living amoebae were isolated in 15 (30 %) domestic tap water samples. No Gram-negative rod bacteria and Pseudomonas spp. were detected in investigated water samples. Two contact lens case samples and two tap water samples were excluded from the analysis for Pseudomonas spp. for technical reasons. According to our findings, inadequate contact lens maintenance during lens wear may result in the contamination of contact lens storage cases. This situation can lead to severe eye infections in contact lens wearers over time.

  16. Strategy development management of Multimodal Transport Network

    Directory of Open Access Journals (Sweden)

    Nesterova Natalia S.

    2016-01-01

    Full Text Available The article gives a brief overview of works on the development of transport infrastructure for multimodal transportation and integration of Russian transport system into the international transport corridors. The technology for control of the strategy, that changes shape and capacity of Multi-modal Transport Network (MTN, is considered as part of the methodology for designing and development of MTN. This technology allows to carry out strategic and operational management of the strategy implementation based on the use of the balanced scorecard.

  17. Multimodal surveillance sensors, algorithms, and systems

    CERN Document Server

    Zhu, Zhigang

    2007-01-01

    From front-end sensors to systems and environmental issues, this practical resource guides you through the many facets of multimodal surveillance. The book examines thermal, vibration, video, and audio sensors in a broad context of civilian and military applications. This cutting-edge volume provides an in-depth treatment of data fusion algorithms that takes you to the core of multimodal surveillance, biometrics, and sentient computing. The book discusses such people and activity topics as tracking people and vehicles and identifying individuals by their speech.Systems designers benefit from d

  18. Non-Invasive Early Detection and Molecular Analysis of Low X-ray Dose Effects in the Lens

    Energy Technology Data Exchange (ETDEWEB)

    Goldstein, Lee [Boston University

    2014-07-02

    This is the Final Progress Report for DOE-funded research project DE-PS02-08ER08-01 titled “Non-Invasive Early Detection and Molecular Analysis of Low X-ray Dose Effects in the Lens”. The project focuses on the effects of low-linear energy transfer (LET) radiation on the ocular lens. The lens is an exquisitely radiosensitive tissue with a highly-ordered molecular structure that is amenable to non-invasive optical study from the periphery. These merits point to the lens as an ideal target for laser-based molecular biodosimetry (MBD). Following exposure to different types of ionizing radiations, the lens demonstrates molecular changes (e.g., oxidation, racemization, crosslinkage, truncation, aggregation, etc.) that impact the structure and function of the long-lived proteins in the cytosol of lens fiber cells. The vast majority of proteins in the lens comprise the highly-ordered crystallins. These highly conserved lens proteins are amongst the most concentrated and stable in the body. Once synthesized, the crystallins are retained in the fiber cell cytoplasm for life. Taken together, these properties point to the lens as an ideal system for quantitative in vivo MBD assessment using quasi-elastic light scattering (QLS) analysis. In this project, we deploy a purpose-designed non-invasive infrared laser QLS instrument as a quantitative tool for longitudinal assessment of pre-cataractous molecular changes in the lenses of living mice exposed to low-dose low-LET radiation compared to non-irradiated sham controls. We hypothesize that radiation exposure will induce dose-dependent changes in the molecular structure of matrix proteins in the lens. Mechanistic assays to ascertain radiation-induced molecular changes in the lens focus on protein aggregation and gene/protein expression patterns. We anticipate that this study will contribute to our understanding of early molecular changes associated with radiation-induced tissue pathology. This study also affords potential for

  19. Modulation of lens cell adhesion molecules by particle beams

    Science.gov (United States)

    McNamara, M. P.; Bjornstad, K. A.; Chang, P. Y.; Chou, W.; Lockett, S. J.; Blakely, E. A.

    2001-01-01

    Cell adhesion molecules (CAMs) are proteins which anchor cells to each other and to the extracellular matrix (ECM), but whose functions also include signal transduction, differentiation, and apoptosis. We are testing a hypothesis that particle radiations modulate CAM expression and this contributes to radiation-induced lens opacification. We observed dose-dependent changes in the expression of beta 1-integrin and ICAM-1 in exponentially-growing and confluent cells of a differentiating human lens epithelial cell model after exposure to particle beams. Human lens epithelial (HLE) cells, less than 10 passages after their initial culture from fetal tissue, were grown on bovine corneal endothelial cell-derived ECM in medium containing 15% fetal bovine serum and supplemented with 5 ng/ml basic fibroblast growth factor (FGF-2). Multiple cell populations at three different stages of differentiation were prepared for experiment: cells in exponential growth, and cells at 5 and 10 days post-confluence. The differentiation status of cells was characterized morphologically by digital image analysis, and biochemically by Western blotting using lens epithelial and fiber cell-specific markers. Cultures were irradiated with single doses (4, 8 or 12 Gy) of 55 MeV protons and, along with unirradiated control samples, were fixed using -20 degrees C methanol at 6 hours after exposure. Replicate experiments and similar experiments with helium ions are in progress. The intracellular localization of beta 1-integrin and ICAM-1 was detected by immunofluorescence using monoclonal antibodies specific for each CAM. Cells known to express each CAM were also processed as positive controls. Both exponentially-growing and confluent, differentiating cells demonstrated a dramatic proton-dose-dependent modulation (upregulation for exponential cells, downregulation for confluent cells) and a change in the intracellular distribution of the beta 1-integrin, compared to unirradiated controls. In contrast

  20. Orange fiber laser for ophthalmology

    Science.gov (United States)

    Adachi, M.; Kojima, K.; Hayashi, K.

    2007-02-01

    For the light source of photocoagulators for ophthalmology, orange laser is more suitable than green laser because of low scattering loss by the crystalline lens, and low absorption by xanthophylls in the retina. We developed two orange fiber lasers (580 nm and 590 nm) to investigate the effect depending on the difference in the range of orange. The 580nm laser is composed of a 1160 nm fiber laser and a Periodically Polled Lithium Niobate (PPLN) crystal for second harmonic generation. The 1160 nm fiber laser beam is focused into the MgO-doped PPLN crystal whose length is 30 mm with 3-pass configuration. Continuous-wave 1.3 W output power of 580 nm was obtained with 5.8 W input power of 1160nm for the first time. The conversion efficiency was 22%. The band width of the second harmonic was 0.006 nm (FWHM). The 590 nm laser is almost the same as 580 nm laser source. In this case we used a Raman shift fiber to generate 1180 nm, and the output power of 590 nm was 1.4 W. We developed an evaluation model of photocoagulator system using these two laser sources. A 700 mW coagulation output power was obtained with this orange fiber laser photocoagulator system. This is enough power for the eye surgery. We have the prospect of the maintenance-free, long-life system that is completely air-cooled. We are planning to evaluate this photocoagulator system in order to investigate the difference between the two wavelengths at the field test.

  1. Near-infrared absorption fiber-optic sensors for ultra-sensitive CO2 detection

    Science.gov (United States)

    Chong, Xinyuan; Kim, Ki-Joong; Ohodnicki, Paul R.; Chang, Chih-Hung; Wang, Alan X.

    2015-05-01

    We present a fiber-optic sensor working at near-infrared (NIR) wavelength (~1.57μm) for CO2 detection. In order to increase the NIR absorption, we utilize functional sensor materials metalorganic framework (MOF) on the surface of the core of a multimode-fiber with the cladding layer etched away. The selected functional materials demonstrated excellent adsorption capacity of CO2 and significantly increased the detection sensitivity down to 500 ppm with only 8-centimeter absorption length.

  2. Fiber-optic SERS microfluidic chip based on light-induced gold nano-particle aggregation

    Science.gov (United States)

    Liu, Haitao; Liu, Jiansheng; Li, Shaopeng; Chen, Luoyang; Zhou, Hongwen; Zhu, Jinsong; Zheng, Zheng

    2015-10-01

    A novel optofluidic surface-enhanced Raman scattering (SERS) chip was specially designed and fabricated using polydimethylsiloxane (PDMS) and embedded with normal silica multi-mode optical fibers. Unlike in a conventional Raman detection configuration where an angle of 90° is commonly adopted, here the orientations of the excitation fiber and the collection fiber was set at such an obtuse angle so that the light beam from the excitation fiber can illuminate the endface, but is not within the acceptance angle of the collection fiber. It was found that with the laser irradiating on the endface of the collection fiber in the sample solution, the Raman scattering intensity continued to grow and a level about 30-times than its initial intensity was observed, which was understood by light-induced gold nano-particle aggregation. The effects of fibers' coupling angles, positions and laser irradiation power on the aggregation were investigated.

  3. Experimental refractive index determination of the optic fiber's core

    International Nuclear Information System (INIS)

    Oezelsoy, S.

    2005-01-01

    In this work, the Fresnel's fundamental Law was used to be able to obtain the refractive index of the fiber optic's core. The intensity of light reflected from the boundary between two mediums was measured by the optical powermeter (Melles Griot, Universal optical powermeter). In recent technology, the light that is illuminated from the light source can be transported to the boundary region and measured with minimum loss by using the optic fibers which make the measurement more sensitively. The liquid and the optic fiber's core whose refractive indices will be measured are the two mediums and the surface of the optic fiber's core is the boundary region. By dipping the fiber optic probe to the liquids, the reflected light intensities were measured with powermeter via Silicon Detector for single mode fiber and multimode fiber respectively to obtain the refractive index of the optic fiber's core. At this work, because of the using the diode laser with 661,4 nm (FWHM) and He-Ne laser with 632,8 nm (FWHM) the refractive indices were measured at this wavelengthes with the Refractometer (Abbe 60-70, Bellingham+Stanley). If the refractive indices of two mediums are equal, the light doesn't reflect from the boundary. The graphic is drawn depend upon the refractive index of the liquids versus the back reflected light energy and from the minimum point of the curve the effective refractive index of the fiber optic's core is calculated for 661,4 nm and 780 nm

  4. Contact lens compliance among a group of young, university-based lens users in South India.

    Science.gov (United States)

    Noushad, Babu; Saoji, Yeshwant; Bhakat, Premjit; Thomas, Jyothi

    2012-01-01

    To investigate the rate of compliance with the soft contact lens care and maintenance procedures with a focus on contact lens wearing habits, cleaning and disinfecting procedures, and maintenance of lens care accessories in a group of young, university-based contact lens wearers Two hundred and sixteen young soft contact lens wearers with an age range of 18-22 years were selected conveniently from the student population of Manipal University, Manipal, India. After receiving informed consent from the participants, their level of compliance with contact lenses was assessed using a questionnaire. The mean (±SD) age of the participants was 21.86±2.35 years. Out of 216 subjects, only 34% of the lens users were identified to be compliant with the least level of compliance observed in the maintenance of lens care accessories. Conventional users showed significantly (p=0.001) better level of compliance compared to disposable wearers and so did the users who acquired their lenses from clinicians (p=0.001) compared to over-the-counter lens receipt. The gender (p=0.496) and years of experience in contact lens use (p=0.142) did not show any statistically significant difference in the level of compliance. This study demonstrated that non-compliance with lens care procedures among a group of young, university-based soft contact lens wearers is common. The results indicated that all subjects had some degree of non-compliance and the least level of compliance observed in the care of lens accessories.

  5. Tear film physiology and contact lens wear. II. Contact lens-tear film interaction.

    Science.gov (United States)

    Holly, F J

    1981-04-01

    The successful fitting of contact lenses requires the practitioner to take into account many properties of the specific lens type used but the practitioner must also understand patient factors including tear properties, use of appropriate solutions, procedures for lens cleaning, and efficiency of blinking. Selection of appropriate patients, selection of lens type, proper fitting, good maintenance, and training and monitoring of patients increase the probability of achieving success.

  6. Fiber-Coupled Wide Field of View Optical Receiver for High Speed Space Communication

    Science.gov (United States)

    Suddath, Shannon N.

    Research groups at NASA Glenn Research Center are interested in improving data rates on the International Space Station (ISS) using a free-space optical (FSO) link. However, known flexure of the ISS structure is expected to cause misalignment of the FSO link. Passive-control designs for mitigating misalignment are under investigation, including using a fiber-bundle for improved field of view. The designs must overcome the obstacle of coupling directly to fiber, rather than a photodetector, as NASA will maintain the use of small form-factor pluggable optical transceivers (SFPs) in the ISS network. In this thesis, a bundle-based receiver capable of coupling directly to fiber is designed, simulated, and tested in lab. Two 3-lens systems were evaluated for power performance in the lab, one with a 20 mm focal length aspheric lens and the other with a 50 mm focal length aspheric lens. The maximum output power achieved was 8 muW.

  7. Photovoltaic fibers

    Science.gov (United States)

    Gaudiana, Russell; Eckert, Robert; Cardone, John; Ryan, James; Montello, Alan

    2006-08-01

    It was realized early in the history of Konarka that the ability to produce fibers that generate power from solar energy could be applied to a wide variety of applications where fabrics are utilized currently. These applications include personal items such as jackets, shirts and hats, to architectural uses such as awnings, tents, large covers for cars, trucks and even doomed stadiums, to indoor furnishings such as window blinds, shades and drapes. They may also be used as small fabric patches or fiber bundles for powering or recharging batteries in small sensors. Power generating fabrics for clothing is of particular interest to the military where they would be used in uniforms and body armor where portable power is vital to field operations. In strong sunlight these power generating fabrics could be used as a primary source of energy, or they can be used in either direct sunlight or low light conditions to recharge batteries. Early in 2002, Konarka performed a series of proof-of-concept experiments to demonstrate the feasibility of building a photovoltaic cell using dye-sensitized titania and electrolyte on a metal wire core. The approach taken was based on the sequential coating processes used in making fiber optics, namely, a fiber core, e.g., a metal wire serving as the primary electrode, is passed through a series of vertically aligned coating cups. Each of the cups contains a coating fluid that has a specific function in the photocell. A second wire, used as the counter electrode, is brought into the process prior to entering the final coating cup. The latter contains a photopolymerizable, transparent cladding which hardens when passed through a UV chamber. Upon exiting the UV chamber, the finished PV fiber is spooled. Two hundred of foot lengths of PV fiber have been made using this process. When the fiber is exposed to visible radiation, it generates electrical power. The best efficiency exhibited by these fibers is 6% with an average value in the 4

  8. Placement of a crystalline lens and intraocular lens: Retinal image quality.

    Science.gov (United States)

    Siedlecki, Damian; Nowak, Jerzy; Zajac, Marek

    2006-01-01

    The influence of changes of both crystalline lens and intraocular lens (IOL) misalignment on the retinal image quality was investigated. The optical model of the eye used in investigations was the Liou-Brennan model, which is commonly considered as one of the most anatomically accurate. The original crystalline lens from this model was replaced with an IOL, made of rigid polymethylmethacrylate, in a way that recommend obligatory procedures. The modifications that were made both for crystalline lens and IOL were the longitudinal, the transversal, and the angular displacement.

  9. Restoring lens capsule integrity enhances lens regeneration in New Zealand albino rabbits and cats.

    Science.gov (United States)

    Gwon, A; Gruber, L J; Mantras, C

    1993-11-01

    In studies conducted by numerous investigators for 150 years, lenses regenerated following endocapsular lens extraction in New Zealand albino rabbits have been irregular in shape, appearing primarily doughnut-shaped as a result of lack of lens growth at the site of the anterior capsulotomy and its adhesion to the posterior capsule. In the present study, we restored the lens capsule integrity by inserting a collagen patch at the time of surgery to seal the anterior capsulotomy and to improve the shape and structure of the regenerated lenses. We then filled the capsule bag with air to prevent adhesions between the anterior and posterior capsule and maintain capsule tautness and shape. Lens regeneration was first noted as early as one to two weeks. Regenerated lens filled approximately 50% of the capsule bag at two weeks and 100% by five weeks. Subsequent growth was in the anterior-posterior direction and measured by A-scan biometry. Lens thickness increased by 0.3 mm per month. The regenerated lenses were spherical with normal cortical structure and a nuclear opacity. In conclusion, restoration of lens capsular integrity with a collagen patch following endocapsular lens extraction enhanced the shape, structure, and growth rate of the regenerated lenses. In addition, lens regeneration was shown to occur in two cats.

  10. Development of Fresnel lens for improvement of rear visibility; Shikai kojo Fresnel lens no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Iwamoto, K.; Sanada, C.; Tsukino, M. [Nissan Motor Co. Ltd., Tokyo (Japan)

    1997-10-01

    Fresnel lenses have been widely used to increase the visual field around vehicles for drivers. However, internal reflection in these lenses has been an obstacle in producing dear images. This internal glow is generated by incident light from an unexpected direction reflecting on the non-lens surface or radiating from the non-lens surface of the Fresnel lens. The cause of internal glow has been made dear combining louver film with the lens. The newly developed technology removes obstacles in producing dear images by reducing internal glow. 7 figs.

  11. Optical fiber inspection system

    Science.gov (United States)

    Moore, Francis W.

    1987-01-01

    A remote optical inspection system including an inspection head. The inspection head has a passageway through which pellets or other objects are passed. A window is provided along the passageway through which light is beamed against the objects being inspected. A plurality of lens assemblies are arranged about the window so that reflected light can be gathered and transferred to a plurality of coherent optical fiber light guides. The light guides transfer the light images to a television or other image transducer which converts the optical images into a representative electronic signal. The electronic signal can then be displayed on a signal viewer such as a television monitor for inspection by a person. A staging means can be used to support the objects for viewing through the window. Routing means can be used to direct inspected objects into appropriate exit passages for accepted or rejected objects. The inspected objects are advantageously fed in a singular manner to the staging means and routing means. The inspection system is advantageously used in an enclosure when toxic or hazardous materials are being inspected.

  12. Multimodal Student Interaction Online: An Ecological Perspective

    Science.gov (United States)

    Berglund, Therese Ornberg

    2009-01-01

    This article describes the influence of tool and task design on student interaction in language learning at a distance. Interaction in a multimodal desktop video conferencing environment, FlashMeeting, is analyzed from an ecological perspective with two main foci: participation rates and conversational feedback strategies. The quantitative…

  13. Multimodal Design, Learning and Cultures of Recognition

    Science.gov (United States)

    Kress, Gunther; Selander, Staffan

    2012-01-01

    In this article, a design-oriented, multimodal understanding of learning will be outlined. There seems to be a need for a new conceptualisation of learning in an era characterised by an increasing virtual space, blended media and new communicative patterns. This means a broader understanding of learning, and a theoretical understanding of…

  14. Feedback Design in Multimodal Dialogue Systems

    NARCIS (Netherlands)

    Van Rosmalen, Peter; Börner, Dirk; Schneider, Jan; Petukhova, Volha; Van Helvert, Joy

    2015-01-01

    This paper discusses the design and development of the instructional aspects of a multimodal dialogue system to train youth parliament members’ presentation and debating skills. Real-time, in-action feedback informs learners on the fly how they perform key skills and enables them to adapt instantly.

  15. Scenemash: multimodal route summarization for city exploration

    NARCIS (Netherlands)

    Berg, J. van den; Rudinac, S.; Worring, M.

    2016-01-01

    The potential of mining tourist information from social multimedia data gives rise to new applications offering much richer impressions of the city. In this paper we propose Scenemash, a system that generates multimodal summaries of multiple alternative routes between locations in a city. To get

  16. Nanotechnology for Multimodal Synergistic Cancer Therapy.

    Science.gov (United States)

    Fan, Wenpei; Yung, Bryant; Huang, Peng; Chen, Xiaoyuan

    2017-11-22

    The complexity, diversity, and heterogeneity of tumors seriously undermine the therapeutic potential of treatment. Therefore, the current trend in clinical research has gradually shifted from a focus on monotherapy to combination therapy for enhanced treatment efficacy. More importantly, the cooperative enhancement interactions between several types of monotherapy contribute to the naissance of multimodal synergistic therapy, which results in remarkable superadditive (namely "1 + 1 > 2") effects, stronger than any single therapy or their theoretical combination. In this review, state-of-the-art studies concerning recent advances in nanotechnology-mediated multimodal synergistic therapy will be systematically discussed, with an emphasis on the construction of multifunctional nanomaterials for realizing bimodal and trimodal synergistic therapy as well as the intensive exploration of the underlying synergistic mechanisms for explaining the significant improvements in synergistic therapeutic outcome. Furthermore, the featured applications of multimodal synergistic therapy in overcoming tumor multidrug resistance, hypoxia, and metastasis will also be discussed in detail, which may provide new ways for the efficient regression and even elimination of drug resistant, hypoxic solid, or distant metastatic tumors. Finally, some design tips for multifunctional nanomaterials and an outlook on the future development of multimodal synergistic therapy will be provided, highlighting key scientific issues and technical challenges and requiring remediation to accelerate clinical translation.

  17. Reconceptualising Poetry as a Multimodal Genre

    Science.gov (United States)

    Newfield, Denise; D'abdon, Raphael

    2015-01-01

    This conceptual article theorises the role of poetry in English classrooms from a multimodal perspective. It discusses the gap between the practices of poetry inside and outside South African schools, particularly where English is taught as an additional language (EAL). The former is shown to be monomodal and prescriptive, while the latter is…

  18. A Multimodal Database for Mimicry Analysis

    NARCIS (Netherlands)

    Sun, X.; Lichtenauer, Jeroen; Valstar, Michel; Nijholt, Antinus; Pantic, Maja; D' Mello, Sidney; Graesser, Arthur; Schuller, Björn; Martin, Jean-Claude

    2011-01-01

    In this paper we introduce a multi-modal database for the analysis of human interaction, in particular mimicry, and elaborate on the theoretical hypotheses of the relationship between the occurrence of mimicry and human affect. The recorded experiments are designed to explore this relationship. The

  19. CASE REPORT CASE Multimodality imaging and interventional ...

    African Journals Online (AJOL)

    sequestration was considered at this stage. An angiogram was thereafter performed to further characterise the vascularity, as well as allow embolisation of the lesion prior to surgery. (Fig. 5). Multimodality imaging and interventional management of a complex congenital vascular malformation. Aadil Ahmed, MB BCh, FCRad ...

  20. Multimodal Dialogue Management - State of the art

    NARCIS (Netherlands)

    Bui Huu Trung, B.H.T.

    This report is about the state of the art in dialogue management. We first introduce an overview of a multimodal dialogue system and its components. Second, four main approaches to dialogue management are described (finite-state and frame-based, information-state based and probabilistic, plan-based,

  1. Influence of Blood Contamination During Multimode Adhesive ...

    African Journals Online (AJOL)

    Objectives: The present study evaluated the effects of blood contamination performed at different steps of bonding on the microtensile bond strength (μTBS) of multimode adhesives to dentin when using the self-etch approach. Materials and Methods: Seventy-five molars were randomly assigned to three adhesive groups ...

  2. Love that Book: Multimodal Response to Literature

    Science.gov (United States)

    Dalton, Bridget; Grisham, Dana L.

    2013-01-01

    Composing with different modes--image, sound, video and the written word--to respond to and analyze literary and informational text helps students develop as readers and digital communicators. This article showcases five multimodal strategies for engaging children in rich literature-based learning using digital tools and Internet resources.

  3. Multimodal Interaction in a Haptic Environment

    NARCIS (Netherlands)

    Nijholt, Antinus; Kole, S.; Zwiers, Jakob; Bicchi, A.; Bergamasco, M.

    2005-01-01

    In this paper we investigate the introduction of haptics in a multimodal tutoring environment. In this environment a haptic device is used to control a virtual piece of sterile cotton and a virtual injection needle. Speech input and output is provided to interact with a virtual tutor, available as a

  4. Evaluating Multimodal NLG using Production Experiments

    NARCIS (Netherlands)

    van der Sluis, Ielka; Krahmer, E.

    2004-01-01

    In this paper we report on an evaluation study for the generation of multimodal referring expressions. To test our algorithm, which allows for various gradations of preciseness in pointing, subjects performed an object identification task in a strict experimental setting. 20 subjects participated

  5. Magnetic quantum dots for multimodal imaging

    NARCIS (Netherlands)

    Koole, Rolf; Mulder, Willem J. M.; van Schooneveld, Matti M.; Strijkers, Gustav J.; Meijerink, Andries; Nicolay, Klaas

    2009-01-01

    Multimodal contrast agents based on highly luminescent quantum dots (QDs) combined with magnetic nanoparticles (MNPs) or ions form an exciting class of new materials for bioimaging. With two functionalities integrated in a single nanoparticle, a sensitive contrast agent for two very powerful and

  6. Experiential Influences on Multimodal Perception of Emotion

    Science.gov (United States)

    Shackman, Jessica E.; Pollak, Seth D.

    2005-01-01

    The impact of 2 types of learning experiences on children's perception of multimodal emotion cues was examined. Children (aged 7-12 years) were presented with conflicting facial and vocal emotions. The effects of familiarity were tested by varying whether emotions were presented by familiar or unfamiliar adults. The salience of particular…

  7. Single versus multimodality training basic laparoscopic skills

    NARCIS (Netherlands)

    Brinkman, W.M.; Havermans, S.Y.; Buzink, S.N.; Botden, S.M.B.I.; Jakimowicz, J.J.; Schoot, B.C.

    2012-01-01

    Introduction - Even though literature provides compelling evidence of the value of simulators for training of basic laparoscopic skills, the best way to incorporate them into a surgical curriculum is unclear. This study compares the training outcome of single modality training with multimodality

  8. Multimodal Interaction with a Virtual Guide

    NARCIS (Netherlands)

    Hofs, D.H.W.; Theune, Mariet; op den Akker, Hendrikus J.A.

    2008-01-01

    We demonstrate the Virtual Guide, an embodied conversational agent that gives directions in a 3D environment. We briefly describe multimodal dialogue management, language and gesture generation, and a special feature of the Virtual Guide: the ability to align her linguistic style to the user’s level

  9. A Multimodal Interaction Framework for Blended Learning

    DEFF Research Database (Denmark)

    Vidakis, Nikolaos; Kalafatis, Konstantinos; Triantafyllidis, Georgios

    2016-01-01

    of communication with an application, which will be more natural than the traditional “windows, icons, menus, pointer” (WIMP) style. Despite the great amount of devices in existence, most applications make use of a very limited set of modalities, most notably speech and touch. This paper describes a multimodal...

  10. Raman imaging of carious lesions using a hollow optical fiber probe.

    Science.gov (United States)

    Yokoyama, Eriko; Kakino, Satoko; Matsuura, Yuji

    2008-08-10

    Raman spectroscopy using a hollow optical fiber probe with a glass ball lens at the distal end is proposed for detection of early caries lesions. Raman spectroscopy on carious lesions of extracted teeth showed that the probe enables measurement with a high signal-to-noise ratio when combined with a ball lens with a high refractive index. The proposed probe and lens combination detects changes in Raman spectra caused by morphological differences between sound and carious enamel. We also obtained a high-contrast image of an early carious lesion by scanning the tooth surface with the probe.

  11. Night Vision Goggles Objectives Lens Focusing Methodology

    National Research Council Canada - National Science Library

    Pinkus, Alan; Task, H. L

    2000-01-01

    ...: interpupillary distance, tilt, eye relief, height, eyepiece and objective lens focus. Currently, aircrew use a Hoffman 20/20 test unit to pre-focus their NVG objective lenses at optical infinity before boarding their aircraft...

  12. Complex approach to the investigation of short fiber-optic comunication lines

    Science.gov (United States)

    Sukhoivanov, I. A.; Kontar', A. A.; Kublik, A. V.; Makarevich, V. S.

    The paper proposes a method of complex measurements based on the consideration of the parameters of all the elements used in a specific multimode fiber-optic communication line. It is shown that the error in measuring losses in waveguides up to 20 m long can reach a value of 60 percent.

  13. Ethernet Based Passive Optical Local Area Networks for Fiber-to-the-Desk Application

    NARCIS (Netherlands)

    Radovanovic, Igor; van Etten, Wim; Freriks, Hennie

    2003-01-01

    We introduce optical local-area network (LAN) architectures based on multimode optical fiber and components, short wavelength lasers and detectors, and the widely used fast Ethernet protocol. These architectures are designed to lower the costs associated with passive optical LAN implementation.

  14. The Role of Type IV Collagen in Developing Lens in Mouse Fetuses

    Directory of Open Access Journals (Sweden)

    Mehdi Jalali

    2009-09-01

    Full Text Available Objective(sExtracellular matrix (ECM and basement membrane (BM play important roles in many developmental processes during development and after birth. Among the components of the BM, collagen fibers specially type IV are the most important parts. The aim of this study was to determine the time when collagen type IV appears in the BM of lens structure during mouse embryonic development.Materials and MethodsIn this experimental study, 22 female Balb/C mice were randomly selected and were kept under normal condition, finding vaginal plug was assumed as day zero of pregnancy. From embryonic day 10 to 20, all specimens were sacrificed by cervical dislocation and their heads were fixed, serially sectioned and immunohistochemistry study for tracing collagen type IV in lens were carried out.ResultsOur data revealed that collagen type IV appeared at the early stage of gestation day 12 in BM of anterior epithelial lens cells and the amount of this protein gradually increased until days 15-17 in ECM and posterior capsule epithelium. After this period, severe reaction was not observed in any part of the lens.ConclusionThese findings establish the important role of collagen IV in developing optic cup and any changes during critical period of pregnancy may be result in severe visual system defect

  15. Contractual considerations in contact lens practice.

    Science.gov (United States)

    Classé, J G

    1986-03-01

    The use of forms in contact lens practice can save time, promote patient education, and reduce the opportunity for legal or economic disputes. The most commonly employed forms are those for contact lens fitting agreements, instructions for care and maintenance of lenses, prepaid service agreements, clinical investigations of investigatory lenses or solutions, and for extended wear patients. Sample forms are utilized for purposes of illustration.

  16. Evolution and the Calcite Eye Lens

    OpenAIRE

    Williams, Vernon L.

    2013-01-01

    Calcite is a uniaxial, birefringent crystal, which in its optically transparent form, has been used for animal eye lenses, the trilobite being one such animal. Because of the calcite birefringence there is a difficulty in using calcite as a lens. When the propagation direction of incoming light is not exactly on the c-axis, the mages blur. In this paper, calcite blurring is evaluated, and the non-blurring by a crystallin eye lens is compared to a calcite one.

  17. Acute lens-induced glaucomas: A review

    Directory of Open Access Journals (Sweden)

    Syed Shoeb Ahmad

    2017-02-01

    Full Text Available Lens-induced factors are important and common mechanisms causing acute elevation of intraocular pressure. While in most cases, the diagnosis and management are straight-forward, in others it is difficult and can lead to improper procedures, complications and poor visual outcomes. This review was done with the aim of studying the various types of lens-induced glaucomas, classifying them in an easy way to understand manner, their clinical features, current management and future possibilities.

  18. Facilitating Multiple Intelligences Through Multimodal Learning Analytics

    Directory of Open Access Journals (Sweden)

    Ayesha PERVEEN

    2018-01-01

    Full Text Available This paper develops a theoretical framework for employing learning analytics in online education to trace multiple learning variations of online students by considering their potential of being multiple intelligences based on Howard Gardner’s 1983 theory of multiple intelligences. The study first emphasizes the need to facilitate students as multiple intelligences by online education systems and then suggests a framework of the advanced form of learning analytics i.e., multimodal learning analytics for tracing and facilitating multiple intelligences while they are engaged in online ubiquitous learning. As multimodal learning analytics is still an evolving area, it poses many challenges for technologists, educationists as well as organizational managers. Learning analytics make machines meet humans, therefore, the educationists with an expertise in learning theories can help technologists devise latest technological methods for multimodal learning analytics and organizational managers can implement them for the improvement of online education. Therefore, a careful instructional design based on a deep understanding of students’ learning abilities, is required to develop teaching plans and technological possibilities for monitoring students’ learning paths. This is how learning analytics can help design an adaptive instructional design based on a quick analysis of the data gathered. Based on that analysis, the academicians can critically reflect upon the quick or delayed implementation of the existing instructional design based on students’ cognitive abilities or even about the single or double loop learning design. The researcher concludes that the online education is multimodal in nature, has the capacity to endorse multiliteracies and, therefore, multiple intelligences can be tracked and facilitated through multimodal learning analytics in an online mode. However, online teachers’ training both in technological implementations and

  19. LENS: Science Scope and Development Stages

    Science.gov (United States)

    Vogelaar, R. Bruce

    2013-04-01

    The Low-Energy Neutrino Spectroscopy (LENS) experiment will resolve the solar metallicity question via measurement of the CNO neutrino flux, as well as test the predicted equivalence of solar luminosity as measured by photon versus neutrinos. The LENS detector uses charged-current interaction of neutrinos on Indium-115 (loaded in a scintillator, InLS) to reveal the complete solar neutrino spectrum. LENS's optically segmented 3D lattice geometry achieves precise time and spatial resolution and unprecedented background rejection and sensitivity for low-energy neutrino events. This first-of-a-kind lattice design is also suited for a range of other applications where high segmentation and large light collection are required (eg: sterile neutrinos with sources, double beta decay, and surface detection of reactor neutrinos). The physics scope, detector design, and logic driving the microLENS and miniLENS prototyping stages will be presented. The collaboration is actively running programs; building, operating, developing, and simulating these prototypes using the Kimballton Underground Research Facility (KURF). New members are welcome to the LENS Collaboration, and interested parties should contact R. Bruce Vogelaar.

  20. Modal-interference-based temperature sensing using plastic optical fibers: markedly enhanced sensitivity near glass-transition temperature

    Science.gov (United States)

    Numata, Goki; Hayashi, Neisei; Tabaru, Marie; Mizuno, Yosuke; Nakamura, Kentaro

    2015-07-01

    We developed strain and temperature sensors based on multimode interference in perfluorinated graded-index (GI) plastic optical fibers, and investigate their sensing performance at 1300 nm. At room temperature, we achieve ultra-high sensitivities of strain and temperature of -112 pm/μɛ and +49.8 nm/°C/m, the absolute value of which are approximately 7.2 and over 1800 times as large as those in silica GI multimode fibers, respectively. We also find that the temperature sensitivity is drastically enhanced with increasing temperature toward ~80 °C, where phase transition of core polymer partially occurs.

  1. Preliminary Results from in Situ Quartz Fiber Neutron Irradiations

    CERN Document Server

    Akchurin, Nural; Ayan, S; Ayan, S; Bencze, Gyorgy; Dumano, I; Fenyvesi, Andras; Hauptman, John M; Merlo, Jean-Pierre; Miller, Michael; Önel, Y M; McCliment, Edward; Schwellenbach, D

    1998-01-01

    Optical transmission characteristics of multi-mode synthetic silica-core fibers between 325 nm and 800 nm were studied in situ while irradiated with neutrons. In one case, fiber samples were placed in the core of a 10-kWatt reactor; in the other, fast neutrons generated by p ( 18 MeV) + Be reaction in a cyclotron, irradiated the fibers. The neutron fluence in both studies totaled ~10^15 n/cm2. Both of these initial studies indicate that in the sensitivity region of bialkiline PMTs, the irradiation induced loss is ~1dB/m. These initial experiments are aimed at establishing a fiber testing methodology for assessing the expected degradation of the CMS forward calorimeter at the LHC due to large neutron backgrounds.

  2. Submarine optical fiber cable: development and laying results.

    Science.gov (United States)

    Kojima, N; Yabuta, T; Negishi, Y; Iwabuchi, K; Kawata, O; Yamashita, K; Miyajima, Y; Yoshizawa, N

    1982-03-01

    This paper describes the structural design, trial production, and laying results for submarine optical fiber cables that can be deployed in shallow seas between islands and/or channel crossings without repeaters. Structural design methods for the submarine optical fiber cable are proposed, which take into consideration suppressing cable elongation under tension and excess loss under hydraulic pressure. This paper describes good laying results for the cable using this structural design method. The average loss for single-mode fibers was 0.72 dB/km, and the average loss for multimode fibers was 0.81 dB/km for a 10.2-km long cable operated at 1.3-microm wavelength.

  3. Coherent fiber supercontinuum laser for nonlinear biomedical imaging

    DEFF Research Database (Denmark)

    Tu, Haohua; Liu, Yuan; Liu, Xiaomin

    2012-01-01

    Nonlinear biomedical imaging has not benefited from the well-known techniques of fiber supercontinuum generation for reasons such as poor coherence (or high noise), insufficient controllability, low spectral power intensity, and inadequate portability. Fortunately, a few techniques involving...... nonlinear fiber optics and femtosecond fiber laser development have emerged to overcome these critical limitations. These techniques pave the way for conducting point-of-care nonlinear biomedical imaging by a low-maintenance cost-effective coherent fiber supercontinuum laser, which covers a broad emission...... wavelength of 350-1700 nm. A prototype of this laser has been demonstrated in label-free multimodal nonlinear imaging of cell and tissue samples.© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only....

  4. MIMO signal progressing with RLSCMA algorithm for multi-mode multi-core optical transmission system

    Science.gov (United States)

    Bi, Yuan; Liu, Bo; Zhang, Li-jia; Xin, Xiang-jun; Zhang, Qi; Wang, Yong-jun; Tian, Qing-hua; Tian, Feng; Mao, Ya-ya

    2018-01-01

    In the process of transmitting signals of multi-mode multi-core fiber, there will be mode coupling between modes. The mode dispersion will also occur because each mode has different transmission speed in the link. Mode coupling and mode dispersion will cause damage to the useful signal in the transmission link, so the receiver needs to deal received signal with digital signal processing, and compensate the damage in the link. We first analyzes the influence of mode coupling and mode dispersion in the process of transmitting signals of multi-mode multi-core fiber, then presents the relationship between the coupling coefficient and dispersion coefficient. Then we carry out adaptive signal processing with MIMO equalizers based on recursive least squares constant modulus algorithm (RLSCMA). The MIMO equalization algorithm offers adaptive equalization taps according to the degree of crosstalk in cores or modes, which eliminates the interference among different modes and cores in space division multiplexing(SDM) transmission system. The simulation results show that the distorted signals are restored efficiently with fast convergence speed.

  5. Sharing of secondary electrons by in-lens and out-lens detector in low-voltage scanning electron microscope equipped with immersion lens.

    Science.gov (United States)

    Kumagai, Kazuhiro; Sekiguchi, Takashi

    2009-03-01

    To understand secondary electron (SE) image formation with in-lens and out-lens detector in low-voltage scanning electron microscopy (LV-SEM), we have evaluated SE signals of an in-lens and an out-lens detector in LV-SEM. From the energy distribution spectra of SEs with various boosting voltages of the immersion lens system, we revealed that the electrostatic field of the immersion lens mainly collects electrons with energy lower than 40eV, acting as a low-pass filter. This effect is also observed as a contrast change in LV-SEM images taken by in-lens and out-lens detectors.

  6. Integrating multimodal information for intraoperative assistance in neurosurgery

    Directory of Open Access Journals (Sweden)

    Eisenmann U.

    2015-09-01

    Full Text Available Computer-assisted planning of complex neurosurgical interventions benefits from a variety of specific functions and tools. However, commercial planning- and neuronavigation systems are rather restrictive concerning the availability of innovative methods such as novel imaging modalities, fiber tracking algorithms or electrical dipole mapping. In this respect there is a demand for modular neurosurgical planning systems offering flexible interfaces for easy enhancement. Furthermore all relevant planning information should be available within neuron-avigation. In this work we present a planning system providing these capabilities and its suitability and application in a clinical setting. Our Multimodal Planning System (MOPS 3D offers a variety of tools such as definition of trajectories for minimally invasive surgery, segmentation of ROIs, integration of functional information from atlas maps or magnetoencephalography. It also supplies plugin interfaces for future extensions. For intraoperative application MOPS is coupled with the neuronavigation system Brainlab Vector Vision Cranial/ENT (VVC. We evaluated MOPS in the Department of Neurosurgery at the University Hospital Heidelberg. Surgical planning and navigation was performed in 5 frequently occurring clinical cases. The time necessary for planning was between 5 and 15 minutes including data import, segmentation and planning tasks. The additional information intraoperatively provided by MOPS 3D was highly appreciated by the neurosurgeons and the performance was satisfactory.

  7. Lens and cornea lesions of rats fed corn syrup and the protective effects of alpha lipoic acid.

    Science.gov (United States)

    Gunes, Alime; Ozmen, Ozlem; Saygın, Mustafa; Ascı, Halil; Tok, Levent; Tok, Ozlem; Dıncoglu, Dılnur

    2016-03-01

    To examine the pathological findings that occurred in the lens and cornea and biochemical findings in the lens of rats fed with corn syrup and the protective effects of alpha lipoic acid (ALA). Twenty-four rats were randomly divided into three groups. Group I served as the control group. Group II was used as the study group; the rats were treated with 30% corn sugar solution for 10 weeks. Group III was the treatment group. Corn syrup was given by the oral route to the rats during the study, and ALA (100 mg/kg) was added to the treatment 4 weeks after the study began. At the end of the experiment, central corneal thickness (CCT) was measured in all rats with an ultrasonic pachymeter. Then the right eyes of the rats were enucleated for histopathological examination of the cornea and lens. The left lenses were homogenized for biochemical analyses. The lenses of the rats treated with corn syrup revealed severe damage; many lens fibers appeared swollen and ruptured with large vacuoles near the lens epithelium. In addition, malondialdehyde (MDA) levels, a parameter of oxidative stress, increased but not significantly in Group II; however. ALA treatment decreased MDA levels significantly. Antioxidant enzyme and catalase (CAT) activities were significantly decreased in Group II, and ALA treatment increased these activities; however, the increase was not significant. Changes were observed in the cornea such as epithelial alterations, subepithelial vacuolizations, collagen fibers loss in the stromal layer, interruptions in the subepithelial basement membrane and central corneal thickening. Corn syrup can cause severe damage in rat lenses and corneas. However, ALA ameliorates the effect of corn syrup-related lesions on the cornea and lens.

  8. Recent advances toward a fiber optic sensor for nerve agent

    Science.gov (United States)

    Beshay, Manal; Cordero, Steven R.; Mukamal, Harold; Ruiz, David; Lieberman, Robert A.

    2008-04-01

    We report advances made on the development of a fiber optic nerve agent sensor having its entire length as the sensing element. Upon exposure to sarin gas or its simulant, diisopropyl fluorophosphate, the cladding changes color resulting in an alteration of the light intensity throughput. The optical fiber is multimode and consists of a fused-silica core and a nerve agent sensitive cladding. The absorption characteristics of the cladding affect the fiber's spectral attenuation and limit the length of light guiding fiber that can be deployed continuously. The absorption of the cladding is also dependent on the sensor formulation, which in turn influences the sensitivity of the fiber. In this paper, data related to the trade-off of sensitivity, spectral attenuation, and length of fiber challenged will be reported. The fiber is mass produced using a conventional fiber optic draw tower. This technology could be used to protect human resources and buildings from dangerous chemical attacks, particularly when large areas or perimeters must be covered. It may also be used passively to determine how well such areas have been decontaminated.

  9. Acanthamoeba keratitis and contact lens wear.

    Science.gov (United States)

    Lindsay, Richard G; Watters, Grant; Johnson, Richard; Ormonde, Susan E; Snibson, Grant R

    2007-09-01

    Acanthamoeba keratitis is a rare but serious complication of contact lens wear that may cause severe visual loss. The clinical picture is usually characterised by severe pain, sometimes disproportionate to the signs, with an early superficial keratitis that is often misdiagnosed as herpes simplex virus (HSV) keratitis. Advanced stages of the infection are usually characterised by central corneal epithelial loss and marked stromal opacification with subsequent loss of vision. In this paper, six cases of contact lens-related Acanthamoeba keratitis that occurred in Australia and New Zealand over a three-year period are described. Three of the patients were disposable soft lens wearers, two were hybrid lens wearers and one was a rigid gas permeable lens wearer. For all six cases, the risk factors for Acanthamoeba keratitis were contact lens wear with inappropriate or ineffective lens maintenance and exposure of the contact lenses to tap or other sources of water. All six patients responded well to medical therapy that involved topical use of appropriate therapeutic agents, most commonly polyhexamethylene biguanide and propamidine isethionate, although two of the patients also subsequently underwent deep lamellar keratoplasty due to residual corneal surface irregularity and stromal scarring. Despite the significant advances that have been made in the medical therapy of Acanthamoeba keratitis over the past 10 years, prevention remains the best treatment and patients who wear contact lenses must be thoroughly educated about the proper use and care of the lenses. In particular, exposure of the contact lenses to tap water or other sources of water should be avoided.

  10. Properties of the cathode lens combined with a focusing magnetic/immersion-magnetic lens

    International Nuclear Information System (INIS)

    Konvalina, I.; Muellerova, I.

    2011-01-01

    The cathode lens is an electron optical element in an emission electron microscope accelerating electrons from the sample, which serves as a source for a beam of electrons. Special application consists in using the cathode lens first for retardation of an illuminating electron beam and then for acceleration of reflected as well as secondary electrons, made in the directly imaging low energy electron microscope or in its scanning version discussed here. In order to form a real image, the cathode lens has to be combined with a focusing magnetic lens or a focusing immersion-magnetic lens, as used for objective lenses of some commercial scanning electron microscopes. These two alternatives are compared with regards to their optical properties, in particular with respect to predicted aberration coefficients and the spot size, as well as the optimum angular aperture of the primary beam. The important role of the final aperture size on the image resolution is also presented.

  11. Optical fiber sensors for process refractometry and temperature measuring based on curved fibers

    International Nuclear Information System (INIS)

    Willsch, R.; Schwotzer, G.; Haubenreisser, W.; Jahn, J.U.

    1986-01-01

    Based on U-shape curved multimode fibers with defined bending radii intensity-modulated optical sensors for the determination of refractive index changes in liquids and related measurands (solution concentration, mixing ratio and others) in process-refractometry and for temperature measuring under special environmental conditions have been developed. The optoelectronic transmitting and receiving units are performed in modular technique and can be used in multi-purpose applications. The principles, performance and characteristical properties of these sensors are described and their possibilities of application in process measuring and automation are discussed by some selected examples. (orig.) [de

  12. Fiber Optic Sensors for Health Monitoring of Morphing Airframes. Part 2; Chemical Sensing Using Optical Fibers with Bragg Gratings

    Science.gov (United States)

    Wood, Karen; Brown, Timothy; Rogowski, Robert; Jensen, Brian

    2000-01-01

    Part 1 of this two part series described the fabrication and calibration of Bragg gratings written into a single mode optical fiber for use in strain and temperature monitoring. Part 2 of the series describes the use of identical fibers and additional multimode fibers, both with and without Bragg gratings, to perform near infrared spectroscopy. The demodulation system being developed at NASA Langley Research Center currently requires the use of a single mode optical fiber. Attempts to use this single mode fiber for spectroscopic analysis are problematic given its small core diameter, resulting in low signal intensity. Nonetheless, we have conducted a preliminary investigation using a single mode fiber in conjunction with an infrared spectrometer to obtain spectra of a high-performance epoxy resin system. Spectra were obtained using single mode fibers that contained Bragg gratings; however, the peaks of interest were barely discernible above the noise. The goal of this research is to provide a multipurpose sensor in a single optical fiber capable of measuring a variety of chemical and physical properties.

  13. Miniature fiber-optic multiphoton microscopy system using frequency-doubled femtosecond Er-doped fiber laser.

    Science.gov (United States)

    Huang, Lin; Mills, Arthur K; Zhao, Yuan; Jones, David J; Tang, Shuo

    2016-05-01

    We report on a miniature fiber-optic multiphoton microscopy (MPM) system based on a frequency-doubled femtosecond Er-doped fiber laser. The femtosecond pulses from the laser source are delivered to the miniature fiber-optic probe at 1.58 µm wavelength, where a standard single mode fiber is used for delivery without the need of free-space dispersion compensation components. The beam is frequency-doubled inside the probe by a periodically poled MgO:LiNbO3 crystal. Frequency-doubled pulses at 786 nm with a maximum power of 80 mW and a pulsewidth of 150 fs are obtained and applied to excite intrinsic signals from tissues. A MEMS scanner, a miniature objective, and a multimode collection fiber are further used to make the probe compact. The miniature fiber-optic MPM system is highly portable and robust. Ex vivo multiphoton imaging of mammalian skins demonstrates the capability of the system in imaging biological tissues. The results show that the miniature fiber-optic MPM system using frequency-doubled femtosecond fiber laser can potentially bring the MPM imaging for clinical applications.

  14. Lens exposure during brain scans using multidetector row CT scanners: methods for estimation of lens dose.

    Science.gov (United States)

    Suzuki, S; Furui, S; Ishitake, T; Abe, T; Machida, H; Takei, R; Ibukuro, K; Watanabe, A; Kidouchi, T; Nakano, Y

    2010-05-01

    Some recent studies on radiation lens injuries have indicated much lower dose thresholds than specified by the current radiation protection guidelines. The purpose of this research was to measure the lens dose during brain CT scans with multidetector row CT and to assess methods for estimating the lens dose. With 8 types of multidetector row CT scanners, both axial and helical scans were obtained for the head part of a human-shaped phantom by using normal clinical settings with the orbitomeatal line as the baseline. We measured the doses on both eyelids by using an RPLGD during whole-brain scans including the orbit with the starting point at the level of the inferior orbital rim. To assess the effect of the starting points on the lens doses, we measured the lens doses by using 2 other starting points for scanning (the orbitomeatal line and the superior orbital rim). The CTDIvols and the lens doses during whole-brain CT including the orbit were 50.9-113.3 mGy and 42.6-103.5 mGy, respectively. The ratios of lens dose to CTDIvol were 80.6%-103.4%. The lens doses decreased as the starting points were set more superiorly. The lens doses during scans from the superior orbital rim were 11.8%-20.9% of the doses during the scans from the inferior orbital rim. CTDIvol can be used to estimate the lens dose during whole-brain CT when the orbit is included in the scanning range.

  15. Proximal design for a multimodality endoscope with multiphoton microscopy, optical coherence microscopy and visual modalities

    Science.gov (United States)

    Kiekens, Kelli C.; Talarico, Olivia; Barton, Jennifer K.

    2018-02-01

    A multimodality endoscope system has been designed for early detection of ovarian cancer. Multiple illumination and detection systems must be integrated in a compact, stable, transportable configuration to meet the requirements of a clinical setting. The proximal configuration presented here supports visible light navigation with a large field of view and low resolution, high resolution multiphoton microscopy (MPM), and high resolution optical coherence microscopy (OCM). All modalities are integrated into a single optical system in the endoscope. The system requires two light sources: a green laser for visible light navigation and a compact fiber based femtosecond laser for MPM and OCM. Using an inline wavelength division multiplexer, the two sources are combined into a single mode fiber. To accomplish OCM, a fiber coupler is used to separate the femtosecond laser into a reference arm and signal arm. The reflected reference arm and the signal from the sample are interfered and wavelength separated by a reflection grating and detected using a linear array. The MPM signal is collimated and goes through a series of filters to separate the 2nd and 3rd harmonics as well as twophoton excitation florescence (2PEF) and 3PEF. Each signal is independently detected on a photo multiplier tube and amplified. The visible light is collected by multiple high numerical aperture fibers at the endoscope tip which are bundled into one SMA adapter at the proximal end and connected to a photodetector. This integrated system design is compact, efficient and meets both optical and mechanical requirements for clinical applications.

  16. Multimodal mechanisms of food creaminess sensation.

    Science.gov (United States)

    Chen, Jianshe; Eaton, Louise

    2012-12-01

    In this work, the sensory creaminess of a set of four viscosity-matched fluid foods (single cream, evaporated milk, corn starch solution, and corn starch solution containing long chain free fatty acids) was tested by a panel of 16 assessors via controlled sensation mechanisms of smell only, taste only, taste and tactile, and integrated multimodal. It was found that all sensation channels were able to discriminate between creamy and non-creamy foods, but only the multimodal method gave creaminess ratings in agreement with the samples' fat content. Results from this study show that the presence of long chain free fatty acids has no influence on creaminess perception. It is certain that food creaminess is not a primary sensory property but an integrated sensory perception (or sensory experience) derived from combined sensations of visual, olfactory, gustatory, and tactile cues. Creamy colour, milky flavour, and smooth texture are probably the most important sensory features of food creaminess.

  17. Multimodality imaging of the postoperative shoulder

    Energy Technology Data Exchange (ETDEWEB)

    Woertler, Klaus [Technische Universitaet Muenchen, Department of Radiology, Munich (Germany)

    2007-12-15

    Multimodality imaging of the postoperative shoulder includes radiography, magnetic resonance (MR) imaging, MR arthrography, computed tomography (CT), CT arthrography, and ultrasound. Target-oriented evaluation of the postoperative shoulder necessitates familiarity with surgical techniques, their typical complications and sources of failure, knowledge of normal and abnormal postoperative findings, awareness of the advantages and weaknesses with the different radiologic techniques, and clinical information on current symptoms and function. This article reviews the most commonly used surgical procedures for treatment of anterior glenohumeral instability, lesions of the labral-bicipital complex, subacromial impingement, and rotator cuff lesions and highlights the significance of imaging findings with a view to detection of recurrent lesions and postoperative complications in a multimodality approach. (orig.)

  18. Multimodal pain management after arthroscopic surgery

    DEFF Research Database (Denmark)

    Rasmussen, Sten

    Multimodal Pain Management after Arthroscopic Surgery By Sten Rasmussen, M.D. The thesis is based on four randomized controlled trials. The main hypothesis was that multimodal pain treatment provides faster recovery after arthroscopic surgery. NSAID was tested against placebo after knee arthroscopy....... Intraarticular bupivacaine plus morphine plus steroid was tested against bupivacaine plus morphine and against saline in two trials after arthroscopic knee meniscectomy and diagnostic knee arthroscopy respectively. Intraarticular bupivacaine plus morphine plus steroid was tested against saline after operative...... with bupivacaine plus morphine and bupivacaine plus morphine plus steroid after diagnostic knee arthroscopy reduced time to work from 10 to 5 to 2 days. Additional analysis revealed that the surgical trauma and the use of tourniquet influenced recovery. The thesis proves a reduction in the time to return to work...

  19. Semiconductor laser using multimode interference principle

    Science.gov (United States)

    Gong, Zisu; Yin, Rui; Ji, Wei; Wu, Chonghao

    2018-01-01

    Multimode interference (MMI) structure is introduced in semiconductor laser used in optical communication system to realize higher power and better temperature tolerance. Using beam propagation method (BPM), Multimode interference laser diode (MMI-LD) is designed and fabricated in InGaAsP/InP based material. As a comparison, conventional semiconductor laser using straight single-mode waveguide is also fabricated in the same wafer. With a low injection current (about 230 mA), the output power of the implemented MMI-LD is up to 2.296 mW which is about four times higher than the output power of the conventional semiconductor laser. The implemented MMI-LD exhibits stable output operating at the wavelength of 1.52 μm and better temperature tolerance when the temperature varies from 283.15 K to 293.15 K.

  20. Multimodal interaction in image and video applications

    CERN Document Server

    Sappa, Angel D

    2013-01-01

    Traditional Pattern Recognition (PR) and Computer Vision (CV) technologies have mainly focused on full automation, even though full automation often proves elusive or unnatural in many applications, where the technology is expected to assist rather than replace the human agents. However, not all the problems can be automatically solved being the human interaction the only way to tackle those applications. Recently, multimodal human interaction has become an important field of increasing interest in the research community. Advanced man-machine interfaces with high cognitive capabilities are a hot research topic that aims at solving challenging problems in image and video applications. Actually, the idea of computer interactive systems was already proposed on the early stages of computer science. Nowadays, the ubiquity of image sensors together with the ever-increasing computing performance has open new and challenging opportunities for research in multimodal human interaction. This book aims to show how existi...

  1. Multimodal location estimation of videos and images

    CERN Document Server

    Friedland, Gerald

    2015-01-01

    This book presents an overview of the field of multimodal location estimation, i.e. using acoustic, visual, and/or textual cues to estimate the shown location of a video recording. The authors' sample research results in this field in a unified way integrating research work on this topic that focuses on different modalities, viewpoints, and applications. The book describes fundamental methods of acoustic, visual, textual, social graph, and metadata processing as well as multimodal integration methods used for location estimation. In addition, the text covers benchmark metrics and explores the limits of the technology based on a human baseline. ·         Discusses localization of multimedia data; ·         Examines fundamental methods of establishing location metadata for images and videos (other than GPS tagging); ·         Covers Data-Driven as well as Semantic Location Estimation.

  2. The multimodal argumentation of persuasive counter discourses

    DEFF Research Database (Denmark)

    Maier, Carmen Daniela

    with the characteristics and potential fallacies of the advertising discourse of commercials. The original advertising discourse is deconstructed and reconstructed with additional visual material in front of the viewers’ eyes who are instructed by a voiceover narrator what to look at and how to identify and decode...... and critical participants in the process of message understanding. In this paper, I explore the Media Bites videos that identify and discuss problematic gender issues in commercials advertising various products. I adopt a multimodal approach in my discourse analysis and I establish which semiotic modes....... 2008. Mediation, text and action. In Bhatia V.K., J. Flowerdew and R. H. Jones (Eds.) Advances in Discourse Studies. London: Routledge, pp. 211- 228. Santulli, F. 2007. The rhetoric of multimodality: the persuasive power of visual-verbal interplay. In G. Garzone, G. Poncini and P. Cantenaccio (Eds...

  3. Multimodality therapy of local regional esophageal cancer.

    Science.gov (United States)

    Kelsen, David P

    2005-12-01

    Recent trials regarding the use of multimodality therapy for patients with cancers of the esophagus and gastroesophageal junction have not conclusively shown benefit. Regimens containing cisplatin and fluorouracil administered preoperatively appear to be tolerable and do not increase operative morbidity or mortality when compared with surgery alone. Yet clinical trials have not clearly shown that such regimens improve outcome as measured by survival. Likewise, trials of postoperative chemoradiation have not reported a significant improvement in median or overall survival. The reasons for the lack of clinical benefit from multimodality therapy are not completely understood, but improvements in systemic therapy will probably be necessary before disease-free or overall survival improves substantially. Some new single agents such as the taxanes (docetaxel or paclitaxel) and the camptothecan analog irinotecan have shown modest activity for palliative therapy.

  4. Development of Powerhouse Using Fresnel lens

    Directory of Open Access Journals (Sweden)

    Al-Dohani Nawar Saif

    2018-01-01

    Full Text Available Solar energy is an alternative source of renewable energy. Sultanate of Oman government showed initiation on utilization of solar energy for domestic and industrial applications. Fresnel lens is one of the methods to collect maximum energy by gathering heat of the sun in the concentrated form (using solar collectors. Earlier research work discloses that Fresnel lens gave better result in terms of power output and produces lower heat loss as compared to linear –parabolic solar collectors. In this work, development of a proto Fresnel lens power house was made to generate electricity. The focused heat from Fresnel lens was used to heat the molten salt in a heat exchanger to produce the steam. The generated steam was used to rotate the steam engine coupled to a generator. In the current work, a maximum power of 30 W was produced. In addition, comparative study was carried out regarding solar salts and heat exchanger materials to understand the Fresnel powerhouse performance. Overall the present study gave valuable information regarding usage of Fresnel lens for electricity generation in Oman.

  5. Non-compliance in contact lens wear.

    Science.gov (United States)

    Claydon, B E; Efron, N

    1994-10-01

    Non-compliance is emerging as a critical issue in the contact lens field. This problem has been studied at depth in general health care situations and is seen as the responsibility of both practitioner and patient (client) working in a health care partnership. The contact lens practitioner and patient present a specific case for the study of non-compliance in areas such as hygiene, solution use, appointment attendance and wearing times. From 40 to 91% of contact lens patients have been reported as non-complaint in the use of recommended care and maintenance regimens and many of these are confused or ignorant about their behaviour. In order to arrive at a general set of conclusions from the studies published to date, it is important to understand the methodology of each study, it purpose, the definition of non-compliance used and the way the results were analysed and described. This review summarizes the research into non-compliance in the contact lens field to data. A set of general conclusions is drawn and a model for compliance in the context of contact lens practice is proposed.

  6. Spherical aberration in contact lens wear.

    Science.gov (United States)

    Lindskoog Pettersson, A; Jarkö, C; Alvin, A; Unsbo, P; Brautaset, R

    2008-08-01

    The aim of the present studies was to investigate the effect on spherical aberration of different non custom-made contact lenses, both with and without aberration control. A wavefront analyser (Zywave, Bausch & Lomb) was used to measure the aberrations in each subject's right eye uncorrected and with the different contact lenses. The first study evaluated residual spherical aberration with a standard lens (Focus Dailies Disposable, Ciba Vision) and with an aberration controlled contact lens (ACCL) (Definition AC, Optical Connection Inc.). The second study evaluated the residual spherical aberrations with a monthly disposable silicone hydrogel lens with aberration reduction (PureVision, Bausch & Lomb). Uncorrected spherical aberration was positive for all pupil sizes in both studies. In the first study, residual spherical aberration was close to zero with the standard lens for all pupil sizes whereas the ACCL over-corrected spherical aberration. The results of the second study showed that the monthly disposable lens also over-corrected the aberration making it negative. The changes in aberration were statistically significant (plenses. Since the amount of aberration varies individually we suggest that aberrations should be measured with lenses on the eye if the aim is to change spherical aberration in a certain direction.

  7. A lazy way to design infrared lens

    Science.gov (United States)

    Qiu, RongSheng; Wu, JianDong; Chen, LongJiang; Yu, Kun; Pang, HaoJun; Hu, BaiZhen

    2017-08-01

    We designed a compact middle-wave infrared (MWIR) lens with a large focal length ratio (about 1.5:1), used in the 3.7 to 4.8 μm range. The lens is consisted of a compact front group and a re-imaging group. Thanks to the compact front group configuration, it is possible to install a filter wheel mechanism in such a tight space. The total track length of the lens is about 50mm, which includes a 2mm thick protective window and a cold shield of 12mm. The full field of view of the lens is about 3.6°, and F number is less than 1.6, the image circle is about 4.6mm in diameter. The design performance of the lens reaches diffraction limitation, and doesn't change a lot during a temperature range of -40°C +60°C. This essay proposed a stepwise design method of infrared optical system guided by the qualitative approach. The method fully utilize the powerful global optimization ability, with a little effort to write code snippet in optical design software, frees optical engineer from tedious calculation of the original structure.

  8. TESS Lens-Bezel Assembly Modal Testing

    Science.gov (United States)

    Dilworth, Brandon J.; Karlicek, Alexandra

    2017-01-01

    The Transiting Exoplanet Survey Satellite (TESS) program, led by the Kavli Institute for Astrophysics and Space Research at the Massachusetts Institute of Technology (MIT) will be the first-ever spaceborne all-sky transit survey. MIT Lincoln Laboratory is responsible for the cameras, including the lens assemblies, detector assemblies, lens hoods, and camera mounts. TESS is scheduled to be launched in August of 2017 with the primary goal to detect small planets with bright host starts in the solar neighborhood, so that detailed characterizations of the planets and their atmospheres can be performed. The TESS payload consists of four identical cameras and a data handling unit. Each camera consists of a lens assembly with seven optical elements and a detector assembly with four charge-coupled devices (CCDs) including their associated electronics. The optical prescription requires that several of the lenses are in close proximity to a neighboring element. A finite element model (FEM) was developed to estimate the relative deflections between each lens-bezel assembly under launch loads to predict that there are adequate clearances preventing the lenses from making contact. Modal tests using non-contact response measurements were conducted to experimentally estimate the modal parameters of the lens-bezel assembly, and used to validate the initial FEM assumptions. Key Words Non-contact measurements, modal analysis, model validation

  9. cAMP-dependent phosphorylation of bovine lens alpha-crystallin

    International Nuclear Information System (INIS)

    Spector, A.; Chiesa, R.; Sredy, J.; Garner, W.

    1985-01-01

    This communication reports that the A1 and B1 chains of bovine lens alpha-crystallin are phosphorylated. The conclusion is based on the following evidence: (i) When soluble preparations from lens cortex are incubated with [gamma- 32 P]ATP, a cAMP-dependent labeling of a high molecular weight protein is obtained. (ii) After NaDodSO 4 /PAGE, the label is found in two bands with Mr 22,000 and 20,000, corresponding to the B and A chains of alpha-crystallin, respectively. (iii) Isoelectric focusing indicates that the radioactivity is almost exclusively in bands with pI values of 5.58 and 6.70, corresponding to the A1 and B1 chains, respectively. (iv) Similar results are obtained in experiments of [ 32 P]orthophosphate incorporation in lens organ culture. (v) Analyses of the digested protein indicate the label is exclusively in phosphoserine. (vi) 31 P NMR analyses of native, proteolytically digested, and urea-treated alpha-crystallin gives a chemical shift of 4.6 ppm relative to 85% H 3 PO 4 at pH 7.4, suggesting that the phosphate is covalently bound to a serine in the protein. An abundance of approximately one phosphate per four or five monomer units was found. (vii) Similar results were obtained by chemical analyses of independently prepared alpha-crystallin samples. The results are consistent with the view that the A1 and B1 chains arise as result of the phosphorylation of directly synthesized A2 and B2 polypeptides. It is suggested that this metabolically controlled phosphorylation may be associated with the terminal differentiation of the lens epithelial cell and the intracellular organization of the lens fiber cell

  10. Lens Crystallin Modifications and Cataract in Transgenic Mice Overexpressing Acylpeptide Hydrolase*

    Science.gov (United States)

    Santhoshkumar, Puttur; Xie, Leike; Raju, Murugesan; Reneker, Lixing; Sharma, K. Krishna

    2014-01-01

    The accumulation of crystallin fragments in vivo and their subsequent interaction with crystallins are responsible, in part, for protein aggregation in cataracts. Transgenic mice overexpressing acylpeptide hydrolase (APH) specifically in the lens were prepared to test the role of protease in the generation and accumulation of peptides. Cataract development was seen at various postnatal days in the majority of mice expressing active APH (wt-APH). Cataract onset and severity of the cataracts correlated with the APH protein levels. Lens opacity occurred when APH protein levels were >2.6% of the total lens protein and the specific activity, assayed using Ac-Ala-p-nitroanilide substrate, was >1 unit. Transgenic mice carrying inactive APH (mt-APH) did not develop cataract. Cataract development also correlated with N-terminal cleavage of the APH to generate a 57-kDa protein, along with an increased accumulation of low molecular weight (LMW) peptides, similar to those found in aging human and cataract lenses. Nontransgenic mouse lens proteins incubated with purified wt-APH in vitro resulted in a >20% increase in LMW peptides. Crystallin modifications and cleavage were quite dramatic in transgenic mouse lenses with mature cataract. Affected lenses showed capsule rupture at the posterior pole, with expulsion of the lens nucleus and degenerating fiber cells. Our study suggests that the cleaved APH fragment might exert catalytic activity against crystallins, resulting in the accumulation of distinct LMW peptides that promote protein aggregation in lenses expressing wt-APH. The APH transgenic model we developed will enable in vivo testing of the roles of crystallin fragments in protein aggregation. PMID:24554718

  11. [Iris hooks and modified capsular tension ring for subluxation lens in patients with Marfan's syndrome].

    Science.gov (United States)

    Wu, Wen-Jie; Zheng, Dan-ying; Zheng, Ying-feng; Cai, Xiao-yu

    2007-02-01

    To evaluate clinical efficiency and safety of the iris hooks and modified capsular tension ring (MCTR) for the treatment of subluxation lens in patients with Marfan's syndrome. This study comprised 5 patients (7 eyes) with Marfan's syndrome and subluxation lens. After 3.2 mm clear cornea incision and continuous curvilinear capsulorhexis (CCC), 2 - 4 disposable nylon iris hooks were inserted through the stab incisions and placed in the capsulorhexis to support the capsule and enlarged the CCC. Following irrigation/aspiration, a MCTR with suture in its eyelet was placed in the capsule bag. After tightening and tying the suture of MCTR, the capsular bag was centered and fixed. A foldable AcrySof one-piece intraocular lens (IOL) was then placed in the capsule bag. Twelve months after the operation, the best corrected visual acuity was >/= 0.8 in six eyes and 0.7 in one eye. The scheimpflug images obtained from the Pentacam demonstrated that the IOL were well centered. UBM showed that all the MCTR and the haptics of the IOL were in the capsule bag, the eyelet of the MCTR was rested stably between the capsulorhexis margin and the iris. The retroillumination photograph indicated that only one eye had obvious posterior capsular opacification. No intraoperative and postoperative complications such as prolapse of vitreous and retina detachment was occurred. The iris hooks can provide excellent intraoperative capsule-lens stability and facilitate the manipulation during operation. MCTR allows additional suture fixation to the eye wall without damaging the capsular bag and maintains the long-term stability of the intraocular lens. Furthermore, MCTR is helpful for avoiding dislocation of the IOL due to progressive weakening of the zonular fibers in some patients and provides long-term safety.

  12. The multimodal treatment of eating disorders

    OpenAIRE

    HALMI, KATHERINE A.

    2005-01-01

    The treatment of eating disorders is based on a multimodal model, recognizing that these disorders do not have a single cause or a predictable course. The treatment strategy is determined by the severity of illness and the specific eating disorder diagnosis. For the treatment of anorexia nervosa, the key elements are medical management, behavioral therapy, cognitive therapy and family therapy, while pharmacotherapy is at best an adjunct to other therapies. In bulimia nervosa...

  13. Learning new skills in Multimodal Enactive Environments

    Directory of Open Access Journals (Sweden)

    Bardy Benoît G.

    2011-12-01

    Full Text Available A European consortium of researchers in movement and cognitive sciences, robotics, and interaction design developed multimodal technologies to accelerate and transfer the (relearning of complex skills from virtual to real environments. The decomposition of skill into functional elements — the subskills — and the enactment of informational variables used as accelerators are here described. One illustration of accelerator using virtual reality in team rowing is described.

  14. IMPROVING STUDENTS‘ LISTENING SKILL THROUGH MULTIMODALITY APPROARCH

    OpenAIRE

    Setyo Prasiyanto Cahyono; Valentina Widya

    2017-01-01

    This research paper unfolds how visual text book in the listening classroom enhance students listening skill. This research tries to analyze the use of visual text book in teaching listening as pedagogical tools from the multimodal discourse analysis (MDA) point of view. There were 26 students as the participants of this research and these students were in the second semester when they joined intermediate listening subject. In teaching intermediate listening, the lecturer used ―Impact Listeni...

  15. Allergic Fungal Rhinosinusitis - Outcomes of Multimodality Treatment

    OpenAIRE

    Baisakhi Bakat; Subhendu Chowdhury; Amitabha Roy Chowdhury; Soumitra Ghosh; Barin Kumar Roychaudhuri

    2013-01-01

    Abstract Objective : To evaluate the treatment outcomes of multimodality therapy for allergic fungal rhinosinusitis. Study Design: Prospective Observational Study. Materials&methods : This study was carried out in the department of ENT & Head neck Surgery, Vivekananda Institute of Medical Sciences, Ramakrishna Mission Seva Pratishthan, Kolkata from January 2010 to July 2011. During this study period of one & half years, 20 subjects having Allergic Fungal Sinusitis were selected fr...

  16. Pattern recognition of neurotransmitters using multimode sensing.

    Science.gov (United States)

    Stefan-van Staden, Raluca-Ioana; Moldoveanu, Iuliana; van Staden, Jacobus Frederick

    2014-05-30

    Pattern recognition is essential in chemical analysis of biological fluids. Reliable and sensitive methods for neurotransmitters analysis are needed. Therefore, we developed for pattern recognition of neurotransmitters: dopamine, epinephrine, norepinephrine a method based on multimode sensing. Multimode sensing was performed using microsensors based on diamond paste modified with 5,10,15,20-tetraphenyl-21H,23H-porphyrine, hemin and protoporphyrin IX in stochastic and differential pulse voltammetry modes. Optimized working conditions: phosphate buffer solution of pH 3.01 and KCl 0.1mol/L (as electrolyte support), were determined using cyclic voltammetry and used in all measurements. The lowest limits of quantification were: 10(-10)mol/L for dopamine and epinephrine, and 10(-11)mol/L for norepinephrine. The multimode microsensors were selective over ascorbic and uric acids and the method facilitated reliable assay of neurotransmitters in urine samples, and therefore, the pattern recognition showed high reliability (RSDneurotransmitters on biological fluids at a lower determination level than chromatographic methods. The sampling of the biological fluids referees only to the buffering (1:1, v/v) with a phosphate buffer pH 3.01, while for chromatographic methods the sampling is laborious. Accordingly with the statistic evaluation of the results at 99.00% confidence level, both modes can be used for pattern recognition and quantification of neurotransmitters with high reliability. The best multimode microsensor was the one based on diamond paste modified with protoporphyrin IX. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Automatic Multimodal Cognitive Load Measurement (AMCLM)

    Science.gov (United States)

    2011-06-01

    increasing, while F2 is decreasing, as cognitive load is increased. Classification results performed on the Stroop test database show that formant...Final Project Report Grant AOARD-10-4029 Automatic Multimodal Cognitive Load Measurement (AMCLM) June 2011 NICTA DSIM Team...past year. At the start of the project, we carried out a literature review on video based physiological measures of cognitive load, focusing on

  18. Multimodal treatment for unresectable pancreatic cancer

    International Nuclear Information System (INIS)

    Katayama, Kanji; Iida, Atsushi; Fujita, Takashi; Kobayashi, Taizo; Shinmoto, Syuichi; Hirose, Kazuo; Yamaguchi, Akio; Yoshida, Masanori

    1998-01-01

    In order to improve in prognosis and quality of life (QOL), the multimodal treatment for unresectable pancreatic cancers were performed. Bypass surgery was carried out for unresectable pancreatic cancer with intraoperative irradiation (IOR). After surgery, patients were treated with the combination of CDDP (25 mg) and MMC (4 mg) administration, intravenously continuous injection of 5-FU (250 mg for 24 hours), external radiation by the high voltage X-ray (1.5 Gy per irradiation, 4 times a week, and during hyperthermia 3 Gy per irradiation) and hyperthermia using the Thermotron RF-8 warmer. Six out of 13 patients received hyperthermia at over 40degC, were obtained PR, and their survival periods were 22, 21, 19, 18, 11 and 8 months and they could return to work. For all patients with pain, the symptom was abolished or reduced. The survival periods in cases of the multimodal treatment were longer than those of only bypass-surgery or of the resective cases with the curability C. The multimodal treatment combined with radiation, hyperthermia and surgery is more useful for the removal of pain and the improvement of QOL, and also expected the improvement of the prognosis than pancreatectomy. And hyperthermia has an important role on the effect of this treatment. (K.H.)

  19. Multimodal treatment for unresectable pancreatic cancer

    Energy Technology Data Exchange (ETDEWEB)

    Katayama, Kanji; Iida, Atsushi; Fujita, Takashi; Kobayashi, Taizo; Shinmoto, Syuichi; Hirose, Kazuo; Yamaguchi, Akio; Yoshida, Masanori [Fukui Medical School, Matsuoka (Japan)

    1998-07-01

    In order to improve in prognosis and quality of life (QOL), the multimodal treatment for unresectable pancreatic cancers were performed. Bypass surgery was carried out for unresectable pancreatic cancer with intraoperative irradiation (IOR). After surgery, patients were treated with the combination of CDDP (25 mg) and MMC (4 mg) administration, intravenously continuous injection of 5-FU (250 mg for 24 hours), external radiation by the high voltage X-ray (1.5 Gy per irradiation, 4 times a week, and during hyperthermia 3 Gy per irradiation) and hyperthermia using the Thermotron RF-8 warmer. Six out of 13 patients received hyperthermia at over 40degC, were obtained PR, and their survival periods were 22, 21, 19, 18, 11 and 8 months and they could return to work. For all patients with pain, the symptom was abolished or reduced. The survival periods in cases of the multimodal treatment were longer than those of only bypass-surgery or of the resective cases with the curability C. The multimodal treatment combined with radiation, hyperthermia and surgery is more useful for the removal of pain and the improvement of QOL, and also expected the improvement of the prognosis than pancreatectomy. And hyperthermia has an important role on the effect of this treatment. (K.H.)

  20. Optimal Face-Iris Multimodal Fusion Scheme

    Directory of Open Access Journals (Sweden)

    Omid Sharifi

    2016-06-01

    Full Text Available Multimodal biometric systems are considered a way to minimize the limitations raised by single traits. This paper proposes new schemes based on score level, feature level and decision level fusion to efficiently fuse face and iris modalities. Log-Gabor transformation is applied as the feature extraction method on face and iris modalities. At each level of fusion, different schemes are proposed to improve the recognition performance and, finally, a combination of schemes at different fusion levels constructs an optimized and robust scheme. In this study, CASIA Iris Distance database is used to examine the robustness of all unimodal and multimodal schemes. In addition, Backtracking Search Algorithm (BSA, a novel population-based iterative evolutionary algorithm, is applied to improve the recognition accuracy of schemes by reducing the number of features and selecting the optimized weights for feature level and score level fusion, respectively. Experimental results on verification rates demonstrate a significant improvement of proposed fusion schemes over unimodal and multimodal fusion methods.

  1. Probing multimode squeezing with correlation functions

    Energy Technology Data Exchange (ETDEWEB)

    Christ, Andreas; Silberhorn, Christine [Applied Physics, University of Paderborn, Warburger Strasse 100, 33098 Paderborn (Germany); Laiho, Kaisa; Eckstein, Andreas; Cassemiro, Katiuscia N, E-mail: Andreas.Christ@uni-paderborn.de [Max Planck Institute for the Science of Light, Guenther-Scharowsky Strasse 1/Bau 24, 91058 Erlangen (Germany)

    2011-03-15

    Broadband multimode squeezers constitute a powerful quantum resource with promising potential for different applications in quantum information technologies such as information coding in quantum communication networks or quantum simulations in higher-dimensional systems. However, the characterization of a large array of squeezers that coexist in a single spatial mode is challenging. In this paper, we address this problem and propose a straightforward method for determining the number of squeezers and their respective squeezing strengths by using broadband multimode correlation function measurements. These measurements employ the large detection windows of the state of the art avalanche photodiodes in order to simultaneously probe the full Hilbert space of the generated state, which enables us to benchmark the squeezed states. Moreover, due to the structure of correlation functions, our measurements are not affected by losses. This is a significant advantage, since detectors with low efficiencies are sufficient. Our approach is less costly than tomographic methods relying on multimode homodyne detection, which is based on much more demanding measurement and analysis tools and appear to be impractical for large Hilbert spaces.

  2. Acanthamoeba, bacterial, and fungal contamination of contact lens storage cases.

    Science.gov (United States)

    Gray, T B; Cursons, R T; Sherwan, J F; Rose, P R

    1995-01-01

    BACKGROUND--Microbial corneal infection is the most serious complication of contact lens wear. Contact lens cases are a recognised potential source of pathogens associated with corneal ulcers. METHODS--This survey established the incidence of protozoal, bacterial, and fungal contact lens case contamination in 101 asymptomatic daily wear cosmetic contact lens wearers from a domiciliary contact lens practice. RESULTS--Eighty two (81%) contact lens cases were found to be contaminated, with 19 (19%) sterile. Of all contact lens cases, 78 (77%) grew bacteria, 24 (24%) fungi, and 20 (20%) protozoa. Acanthamoeba spp were isolated from eight (8%) contact lens cases. Fifty six (55%) contact lens cases yielded mixed bacterial contamination. This is the first contact lens case survey in which hydrogen peroxide disinfection was the major method of contact lens disinfection (75% of subjects) and no home made saline was used. All the contaminating organisms were shown to possess the enzyme catalase that breaks down hydrogen peroxide to oxygen and water. The polymicrobial nature of the biofilms found in many contact lens cases is illustrated electron micrographically. CONCLUSION--Based on data from this and previous studies, the authors conclude with recommendations for contact lens wearers: (1) regular scrubbing of contact lens case interior to disrupt biofilms; (2) exposure of contact lens case to very hot water (> or = 70 degrees C) will kill Acanthamoeba contaminants; (3) allow contact lens case to air dry between uses; (4) if hydrogen peroxide disinfection is preferred, use a two step system; (5) replace contact lens case regularly. Images PMID:7626578

  3. Characterization of lens based photoacoustic imaging system

    Directory of Open Access Journals (Sweden)

    Kalloor Joseph Francis

    2017-12-01

    Full Text Available Some of the challenges in translating photoacoustic (PA imaging to clinical applications includes limited view of the target tissue, low signal to noise ratio and the high cost of developing real-time systems. Acoustic lens based PA imaging systems, also known as PA cameras are a potential alternative to conventional imaging systems in these scenarios. The 3D focusing action of lens enables real-time C-scan imaging with a 2D transducer array. In this paper, we model the underlying physics in a PA camera in the mathematical framework of an imaging system and derive a closed form expression for the point spread function (PSF. Experimental verification follows including the details on how to design and fabricate the lens inexpensively. The system PSF is evaluated over a 3D volume that can be imaged by this PA camera. Its utility is demonstrated by imaging phantom and an ex vivo human prostate tissue sample.

  4. Freeform micromachining of an infrared Alvarez lens

    Science.gov (United States)

    Smilie, Paul J.; Dutterer, Brian S.; Lineberger, Jennifer L.; Davies, Matthew A.; Suleski, Thomas J.

    2011-02-01

    In 1967, Luis Alvarez introduced a novel concept for a focusing lens whereby two transmitting elements with cubic polynomial surfaces yield a composite lens of variable focal length with small lateral shifts. Computer simulations have demonstrated the behavior of these devices, but fabricating the refractive cubic surfaces of the types needed with adequate precision and depth modulation has proven to be challenging using standard methods, and, to the authors' knowledge, Alvarez lens elements have not been previously machined in infrared materials. Recent developments in freeform diamond machining capability have enabled the fabrication of such devices. In this paper, we discuss the fabrication of freeform refractive Alvarez elements in germanium using diamond micro-milling on a five-axis Moore Nanotech® 350FG Freeform Generator. Machining approaches are discussed, and measurements of surface figure and finish are presented. Initial experimental tests of optical performance are also discussed.

  5. Invited review article: the electrostatic plasma lens.

    Science.gov (United States)

    Goncharov, Alexey

    2013-02-01

    The fundamental principles, experimental results, and potential applications of the electrostatic plasma lens for focusing and manipulating high-current, energetic, heavy ion beams are reviewed. First described almost 50 years ago, this optical beam device provides space charge neutralization of the ion beam within the lens volume, and thus provides an effective and unique tool for focusing high current beams where a high degree of neutralization is essential to prevent beam blow-up. Short and long lenses have been explored, and a lens in which the magnetic field is provided by rare-earth permanent magnets has been demonstrated. Applications include the use of this kind of optical tool for laboratory ion beam manipulation, high dose ion implantation, heavy ion accelerator injection, in heavy ion fusion, and other high technology.

  6. 3D printed helical antenna with lens

    KAUST Repository

    Farooqui, Muhammad Fahad

    2016-12-19

    The gain of an antenna can be enhanced through the integration of a lens, however this technique has traditionally been restricted to planar antennas due to fabrication limitations of standard manufacturing processes. Here, with a unique combination of 3D and 2D inkjet printing of dielectric and metallic inks respectively, we demonstrate a Fresnel lens that has been monolithically integrated to a non-planar antenna (helix) for the first time. Antenna measurements show that the integration of a Fresnel lens enhances the gain of a 2-turn helix by around 4.6 dB giving a peak gain of about 12.9 dBi at 8.8 GHz.

  7. An "ESA-affordable" Laue-lens

    DEFF Research Database (Denmark)

    Lund, Niels

    2005-01-01

    With ESA's INTEGRAL mission gamma-ray astronomy has advanced to the point where major scientific advances must be expected from detailed studies of the many new point sources. The interest in developing focusing telescopes operating in the soft gamma-ray regime up to 1 MeV is therefore mounting r...... constraints of a specific medium size launch vehicle. The introduction of the lens mass as a primary design driver has some surprising effects for the choice of material for the crystals and new tradeoff considerations are introduced....... rapidly. Telescopes based on Laue diffraction of gamma-rays from crystals appear as one promising route, although the practical difficulties of realizing a large scale Laue lens are certainly not small. In this paper I have attempted to develop an optimized lens design considering the size and mass...

  8. Reliability of aircraft multimode optical networks

    Czech Academy of Sciences Publication Activity Database

    Bohata, J.; Písařík, M.; Zvánovec, S.; Peterka, Pavel

    2014-01-01

    Roč. 53, č. 9 (2014), 0961021-0961028 ISSN 0091-3286 Institutional support: RVO:67985882 Keywords : Optical fiber coupler * Fused biconical tapered method * Fiber lasers Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 0.954, year: 2014

  9. Multimodal integration of anatomy and physiology classes: How instructors utilize multimodal teaching in their classrooms

    Science.gov (United States)

    McGraw, Gerald M., Jr.

    Multimodality is the theory of communication as it applies to social and educational semiotics (making meaning through the use of multiple signs and symbols). The term multimodality describes a communication methodology that includes multiple textual, aural, and visual applications (modes) that are woven together to create what is referred to as an artifact. Multimodal teaching methodology attempts to create a deeper meaning to course content by activating the higher cognitive areas of the student's brain, creating a more sustained retention of the information (Murray, 2009). The introduction of multimodality educational methodologies as a means to more optimally engage students has been documented within educational literature. However, studies analyzing the distribution and penetration into basic sciences, more specifically anatomy and physiology, have not been forthcoming. This study used a quantitative survey design to determine the degree to which instructors integrated multimodality teaching practices into their course curricula. The instrument used for the study was designed by the researcher based on evidence found in the literature and sent to members of three associations/societies for anatomy and physiology instructors: the Human Anatomy and Physiology Society; the iTeach Anatomy & Physiology Collaborate; and the American Physiology Society. Respondents totaled 182 instructor members of two- and four-year, private and public higher learning colleges collected from the three organizations collectively with over 13,500 members in over 925 higher learning institutions nationwide. The study concluded that the expansion of multimodal methodologies into anatomy and physiology classrooms is at the beginning of the process and that there is ample opportunity for expansion. Instructors continue to use lecture as their primary means of interaction with students. Email is still the major form of out-of-class communication for full-time instructors. Instructors with

  10. Agent-based Multimodal Interface for Dynamically Autonomous Mobile Robots

    National Research Council Canada - National Science Library

    Sofge, Donald; Bugajska, Magdalena; Adams, William; Perzanowski, Dennis; Schultz, Alan

    2003-01-01

    .... The robot implements and integrates a variety of artificial intelligence techniques including a multimodal interface that allows natural language understanding, gesture interpretation, simultaneous...

  11. Multimodal transports in the Unidted States and Europe

    DEFF Research Database (Denmark)

    Ulfbeck, Vibe Garf

    2009-01-01

    Transport law has traditionally been regarded as an international area of the law. The modern multimodal transport, combining different types of transports, has changed this. Multimodal transports are not regulated by any international conventions. In commercial practice, one liability model...... is preferred in Europe whereas another is preferred in the US. In this sense, modern transport law has become reginialized. The regionalization creates difficulties when goods are trasnported between the two regions. Neither the attempt to regulate multimodal transports in the new global UNCITRAL Convention...... for Carriage of Goods, Wholly or Partly by Sea (Rotterdam Rules), nor the proposal for common EU rules on multimodal transports will solve this problem....

  12. The effectiveness of soft contact lens disinfection systems against Acanthamoeba on the lens surface.

    Science.gov (United States)

    Liedel, K K; Begley, C G

    1996-03-01

    This investigation compared the efficacy of three widely used contact lens disinfection systems against an ocular isolate of Acanthamoeba polyphaga. Twenty-seven worn Ciba NewVues lenses were quartered, heat sterilized and inoculated with Acanthamoeba. Lens quarters were then randomly assigned to three experimental groups, with Group A lenses exposed to cleaner and saline rinse only, Group B to disinfection only, and Group C to both cleaner and disinfection. One quarter of each lens served as a control and the other three quarters were experimental. Quantification of viable Acanthamoeba remaining on the lens was performed after each step of the disinfection process. Group A lenses showed no significant difference between the treatments, or the treatments and the control. Group B lenses demonstrated a significant difference (p = 0.0001) between the treatments and the control. In Group C (cleaning and disinfection), the control lens quarters were significantly different (p = 0.037) from the experimental group, but there was no significant difference between the treatments. All three disinfection regimens were very effective in reducing the number of viable Acanthamoeba on the contact lens surface. In the absence of proper cleaning (Group B), AOSept was the most effective of the three. These results also show the importance of thoroughly rubbing the contact lens surface to decrease the number of Acanthamoeba.

  13. Non-compliance with lens care and maintenance in diabetic contact lens wearers.

    Science.gov (United States)

    O'Donnell, Clare; Efron, Nathan

    2004-11-01

    We hypothesize that diabetic contact lens wearers may represent a special group displaying higher levels of compliance with their lens care regimens as a result of learned behaviour relating to maintenance of their diabetic condition. To test this hypothesis, a prospective, single centre, controlled, masked study was performed whereby 29 diabetic contact lens patients and 29 non-diabetic control subjects were issued with disposable hydrogel contact lenses and a multipurpose lens care regimen. All participants were given identical instruction on lens care and maintenance. Compliance levels were assessed at a 12-month aftercare appointment by demonstration and questionnaire. Twenty-four different aspects of compliance were scored, 12 by observation and 12 by questionnaire report, of which only two showed a significant difference between the diabetic and control groups. Although the combined population of contact lens wearers was generally compliant, there were examples of non-compliance in both groups. Neither the duration of diabetes nor the degree of metabolic control appeared to have a significant effect on compliance. The results suggest that eye care practitioners cannot assume that diabetic patients will be more compliant with contact lens care and maintenance than non-diabetic patients.

  14. Analytic models of plausible gravitational lens potentials

    International Nuclear Information System (INIS)

    Baltz, Edward A.; Marshall, Phil; Oguri, Masamune

    2009-01-01

    Gravitational lenses on galaxy scales are plausibly modelled as having ellipsoidal symmetry and a universal dark matter density profile, with a Sérsic profile to describe the distribution of baryonic matter. Predicting all lensing effects requires knowledge of the total lens potential: in this work we give analytic forms for that of the above hybrid model. Emphasising that complex lens potentials can be constructed from simpler components in linear combination, we provide a recipe for attaining elliptical symmetry in either projected mass or lens potential. We also provide analytic formulae for the lens potentials of Sérsic profiles for integer and half-integer index. We then present formulae describing the gravitational lensing effects due to smoothly-truncated universal density profiles in cold dark matter model. For our isolated haloes the density profile falls off as radius to the minus fifth or seventh power beyond the tidal radius, functional forms that allow all orders of lens potential derivatives to be calculated analytically, while ensuring a non-divergent total mass. We show how the observables predicted by this profile differ from that of the original infinite-mass NFW profile. Expressions for the gravitational flexion are highlighted. We show how decreasing the tidal radius allows stripped haloes to be modelled, providing a framework for a fuller investigation of dark matter substructure in galaxies and clusters. Finally we remark on the need for finite mass halo profiles when doing cosmological ray-tracing simulations, and the need for readily-calculable higher order derivatives of the lens potential when studying catastrophes in strong lenses

  15. Photonic crystal based polarization insensitive flat lens

    Science.gov (United States)

    Turduev, M.; Bor, E.; Kurt, H.

    2017-07-01

    The paper proposes a new design of an inhomogeneous artificially created photonic crystal lens structure consisting of annular dielectric rods to efficiently focus both transverse electric and transverse magnetic polarizations of light into the same focal point. The locations of each individual cell that contains the annular dielectric rods are determined according to a nonlinear distribution function. The inner and outer radii of the annular photonic dielectric rods are optimized with respect to the polarization insensitive frequency response of the transmission spectrum of the lens structure. The physical background of the polarization insensitive focusing mechanism is investigated in both spatial and frequency domains. Moreover, polarization independent wavefront transformation/focusing has been explored in detail by investigating the dispersion relation of the structure. Corresponding phase index distribution of the lens is attained for polarization insensitive normalized frequency range of a/λ  =  0.280 and a/λ  =  0.300, where a denotes the lattice constant of the designed structure and λ denotes the wavelength of the incident light. We show the wave transformation performance and focal point movement dynamics for both polarizations of the lens structure by specially adjusting the length of the structure. The 3D finite-difference time domain numerical analysis is also performed to verifiy that the proposed design is able to focus the wave regardless of polarization into approximately the same focal point (difference between focal distances of both polarizations stays below 0.25λ) with an operating bandwidth of 4.30% between 1476 nm and 1541 nm at telecom wavelengths. The main superiorities of the proposed lens structure are being all dielectric and compact, and having flat front and back surfaces, rendering the proposed lens design more practical in the photonic integration process in various applications such as optical switch

  16. Effect of infrared radiation on the lens

    Directory of Open Access Journals (Sweden)

    Aly Eman

    2011-01-01

    Full Text Available Background: Infrared (IR radiation is becoming more popular in industrial manufacturing processes and in many instruments used for diagnostic and therapeutic application to the human eye. Aim : The present study was designed to investigate the effect of IR radiation on rabbit′s crystalline lens and lens membrane. Materials and Methods: Fifteen New Zealand rabbits were used in the present work. The rabbits were classified into three groups; one of them served as control. The other two groups were exposed to IR radiation for 5 or 10 minutes. Animals from these two irradiated groups were subdivided into two subgroups; one of them was decapitated directly after IR exposure, while the other subgroup was decapitated 1 hour post exposure. IR was delivered from a General Electric Lamp model 250R 50/10, placed 20 cm from the rabbit and aimed at each eye. The activity of Na + -K + ATPase was measured in the lens membrane. Soluble lens proteins were extracted and the following measurements were carried out: estimation of total soluble protein, sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE and Fourier transform infrared (FTIR spectroscopy. For comparison between multiple groups, analysis of variance was used with significance level set at P < 0.001. Results: The results indicated a change in the molecular weight of different lens crystalline accompanied with changes in protein backbone structure. These changes increased for the groups exposed to IR for 10 minutes. Moreover, the activity of Na + -K + ATPase significantly decreased for all groups. Conclusions: The protein of eye lens is very sensitive to IR radiation which is hazardous and may lead to cataract.

  17. Facile Fabrication of Animal-Specific Positioning Molds For Multi-modality Molecular Imaging

    International Nuclear Information System (INIS)

    Park, Jeong Chan; Oh, Ji Eun; Woo, Seung Tae

    2008-01-01

    Recently multi-modal imaging system has become widely adopted in molecular imaging. We tried to fabricate animal-specific positioning molds for PET/MR fusion imaging using easily available molding clay and rapid foam. The animal-specific positioning molds provide immobilization and reproducible positioning of small animal. Herein, we have compared fiber-based molding clay with rapid foam in fabricating the molds of experimental animal. The round bottomed-acrylic frame, which fitted into microPET gantry, was prepared at first. The experimental mice was anesthetized and placed on the mold for positioning. Rapid foam and fiber-based clay were used to fabricate the mold. In case of both rapid foam and the clay, the experimental animal needs to be pushed down smoothly into the mold for positioning. However, after the mouse was removed, the fabricated clay needed to be dried completely at 60 .deg. C in oven overnight for hardening. Four sealed pipe tips containing [ 18 F]FDG solution were used as fiduciary markers. After injection of [ 18 F]FDG via tail vein, microPET scanning was performed. Successively, MRI scanning was followed in the same animal. Animal-specific positioning molds were fabricated using rapid foam and fiber-based molding clay for multimodality imaging. Functional and anatomical images were obtained with microPET and MRI, respectively. The fused PET/MR images were obtained using freely available AMIDE program. Animal-specific molds were successfully prepared using easily available rapid foam, molding clay and disposable pipet tips. Thanks to animal-specific molds, fusion images of PET and MR were co-registered with negligible misalignment

  18. The corneal stroma during contact lens wear.

    Science.gov (United States)

    Jalbert, Isabelle; Stapleton, Fiona

    2005-03-01

    Recent technological advances have lead to novel descriptions of the microanatomy of the corneal stroma. In the first section of this review, these findings and the role they play in the maintenance of vital properties such as corneal transparency, mechanical strength, homeostasis, wound-healing response and metabolism are described. In the second part, contact lens induced stromal alterations such as acidosis, oedema, striae, thinning and opacities are reviewed as well as the more recently described phenomenon of microdot deposits and keratocyte loss with an emphasis on how lens wearing stromal effects can be minimised.

  19. Sterilization potential of contact lens solutions

    Directory of Open Access Journals (Sweden)

    Dada Vijay

    1988-01-01

    Full Text Available In a dynamic field of Contact Lens Solutions maintenance of high standards of anti-microbial activity is a must Resterilization Activity Time′ is a universally accepted yardstick for such an evaluation. In this study eight brands of indigenous popular solutions alongwith two FDA approved solutions were tested for their sterilization efficacy: Standardized suspensions of Pseudomonas aeruginosa, Staphylococcus aureus, Candida albicans and Aspergillus fumigatus were used for the purpose. It was observed that the contact lens solutions available ir, the domestic market were not upto the mark Suggestions for improvement have also been made.

  20. Rotman lens for mm-wavelengths

    Science.gov (United States)

    Hall, Leonard T.; Hansen, Hedley J.; Abbott, Derek

    2002-11-01

    The 77 GHz band has been reserved for intelligent cruise control in luxury cars and some public transport services in America and the United Kingdom. The Rotman lens offers a cheap and compact means to extend the single beam systems generally used, to fully functional beam staring arrangements. Rotman lenses have been built for microwave frequencies with limited success. The flexibility of microstrip transmission lines and the advent of fast accurate simulation packages allow practical Rotman lenses to be designed at mm-wavelengths. This paper discusses the limitations of the conventional design approach and predicts the performance of a new Rotman lens designed at 77 GHz.

  1. Pulse transformer for the AA lithium lens

    CERN Document Server

    CERN PhotoLab

    1980-01-01

    The antiprotons emanating from the target were initially focused by a magnetic horn. Later on, a Li-lens was used during operation for the SPS collider, until 1992. A Li-rod (130 mm long, 34 mm in diameter) constituted the secondary of a 1:23 pulse-transformer. The half-sine pulse rose to 1000 kA in 900 microsec. The angular acceptance was 95 mrad. In operation after 1992, for LEAR only, a more modest Li-lens was used (155 mm long, diameter 20 mm, 480 kA, risetime 240 microsec, angular acceptance 75 mrad).

  2. Two mode optical fiber in space optics communication

    Science.gov (United States)

    Hampl, Martin

    2017-11-01

    In our contribution we propose to use of a two-mode optical fiber as a primary source in a transmitting optical head instead of the laser diode. The distribution of the optical intensity and the complex degree of the coherence on the output aperture of the lens that is irradiated by a step-index weakly guiding optical fiber is investigated. In our treatment we take into account weakly guided modes with polarization corrections to the propagation constant and unified theory of second order coherence and polarization of electromagnetic beams.

  3. Immunochemical analyses of soluble lens proteins in some marine fishes

    Digital Repository Service at National Institute of Oceanography (India)

    Menezes, M.R.

    Soluble eye lens proteins of 10 fishes, belonging to the families Clupeidae, Hemirhamphidae, Lactaridae, Scombridae, Stromatidae, Psettodidae, Bothidae and Soleidae were studied by immunoelectrophoresis using the lens antiserum of Sardinella...

  4. IOL Implants: Lens Replacement and Cataract Surgery (Intraocular Lenses)

    Science.gov (United States)

    ... Cataract Surgery vs. Laser-Assisted Cataract Surgery Cataract Vision Simulator Cataract Pictures and Videos: What Do ... Mar. 27, 2018 An intraocular lens (or IOL) is a tiny, artificial lens for the eye. It replaces the eye's ...

  5. Effect of Final Irrigation Protocol and Etching Mode on Bond Strength of a Multimode Adhesive in the Root Canal.

    Science.gov (United States)

    Bitter, Kerstin; Polster, Luise; Askar, Haitham; von Stein-Lausnitz, Manja; Sterzenbach, Guido

    2017-06-08

    To analyze the effects of ethanol for final post space irrigation and etching mode on the bond strength of fiber posts luted with a mild multimode adhesive (pH 2.3) as compared with a reference group using a self-adhesive resin cement (SAR). Human anterior teeth were endodontically treated. After post space preparation, the root canals were irrigated using 1% sodium hypochlorite (NaOCl) applied with passive ultrasonic irrigation, followed by either distilled water (control) or distilled water and ethanol 99% as final post space irrigation. Fiber posts were luted using Futurabond U in self-etch mode (FU-SE), Futurabond U in etch-and-rinse mode (FU-ER), or Futurabond DC (SE) in combination with a dual-curing core buildup material (Grandio Core, all VOCO); alternatively, posts were inserted using a self-adhesive composite cement (RelyX Unicem 2, 3M ESPE). Bond strengths were evaluated using push-out tests following thermocycling (TC) and storage in 0.9% NaCl for 3 months. Mean push-out bond strengths (MPa) were significantly affected by the luting system (p root canal for all materials, with the exception of FU E&R. Mild multimode adhesives exhibit comparable mean bond strengths to a SAR cement within the root canal for luting fiber posts if applied in an etch-and-rinse mode. Using this approach, ethanol application has no positive effects on bond strength.

  6. Soluble vs. insoluble fiber

    Science.gov (United States)

    Insoluble vs. soluble fiber; Fiber - soluble vs. insoluble ... There are 2 different types of fiber -- soluble and insoluble. Both ... water and turns to gel during digestion. This slows digestion. ...

  7. Breaking the glass ceiling: hollow OmniGuide fibers

    Science.gov (United States)

    Johnson, Steven G.; Ibanescu, Mihai; Skorobogatiy, Maksim A.; Weisberg, Ori; Engeness, Torkel D.; Soljacic, Marin; Jacobs, Steven A.; Joannopoulos, John D.; Fink, Yoel

    2002-04-01

    We argue that OmniGuide fibers, which guide light within a hollow core by concentric multilayer films having the property of omnidirectional reflection, have the potential to lift several physical limitations of silica fibers. We show how the strong confinement in OmniGuide fibers greatly suppresses the properties of the cladding materials: even if highly lossy and nonlinear materials are employed, both the intrinsic losses and nonlinearities of silica fibers can be surpassed by orders of magnitude. This feat, impossible to duplicate in an index-guided fiber with existing materials, would open up new regimes for long-distance propagation and dense wavelength-division multiplexing (DWDM). The OmniGuide-fiber modes bear a strong analogy to those of hollow metallic waveguides; from this analogy, we are able to derive several general scaling laws with core radius. Moreover, there is strong loss discrimination between guided modes, depending upon their degree of confinement in the hollow core: this allows large, ostensibly multi-mode cores to be used, with the lowest-loss TE01 mode propagating in an effectively single-mode fashion. Finally, because this TE01 mode is a cylindrically symmetrical ('azimuthally' polarized) singlet state, it is immune to polarization-mode dispersion (PMD), unlike the doubly-degenerate linearly-polarized modes in silica fibers that are vulnerable to birefringence.

  8. Lens autofluorescence is not increased at high altitude

    DEFF Research Database (Denmark)

    Kessel, Line; Kofoed, Peter Kristian; Zubieta-Calleja, Gustavo

    2010-01-01

    PURPOSE: To study the relation between ambient environmental ultraviolet radiation exposure and lens fluorescence. METHODS: Non-invasive lens fluorometry measurements were compared in healthy Bolivian and Danish subjects. Background ultraviolet radiation was 4.5 times higher in Bolivia than in De...... living at sea level at 55 degrees northern latitude. These results suggest that lens ageing, as assessed by lens autofluorometry, is independent of exposure to ultraviolet radiation....

  9. 21 CFR 886.1420 - Ophthalmic lens gauge.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic lens gauge. 886.1420 Section 886.1420...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1420 Ophthalmic lens gauge. (a) Identification. An ophthalmic lens gauge is a calibrated device intended to manually measure the curvature of a...

  10. In vivo study of lens regeneration in Rana cyanophlyctis under ...

    African Journals Online (AJOL)

    SAM

    2014-03-12

    Mar 12, 2014 ... enhanced the percentage lens regeneration not only in young tadpoles but also in froglets. Lens regeneration ability ... Influence of vitamin A and ascorbic acid on lens regeneration in young, mature tadpoles and froglets of the frog Rana cyanophlyctis. Group .... ingested by macrophages. Dorsal iris cells ...

  11. 21 CFR 800.10 - Contact lens solutions; sterility.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Contact lens solutions; sterility. 800.10 Section...) MEDICAL DEVICES GENERAL Requirements for Specific Medical Devices § 800.10 Contact lens solutions... ophthalmic use, including contact lens solutions, should be sterile. It is further evident that such...

  12. Initial Experience With Posterior Chamber Intraocular Lens Implant ...

    African Journals Online (AJOL)

    The results of extracapsular cataract extraction with posterior chamber intraocular lens implant at the Jos University Teaching Hospital are reviewed. The results suggest that despite lack of facilities to calculate the lens power for emmetropia, the use of a standard lens of about 19.0D will provide a good number of our ...

  13. Photonic crystal fibers -

    DEFF Research Database (Denmark)

    Libori, Stig E. Barkou

    2002-01-01

    During this ph.d. work, attention has been focused on understanding and analyzing the modal behavior of micro-structured fibers. Micro-structured fibers are fibers with a complex dielectric toplogy, and offer a number of novel possibilities, compared to standard silica based optical fibers......, and nonlinear fibers with zero dispersion wavelength well below 1300 nm. This thesis dexcribes the functionalities of these fibers, and further point to novel application areas, such as new efficient fiber amplifiers and fibers with new possibilities within dispersion management. When pointing toward novel...

  14. Vitrectorhexis and lens aspiration with posterior chamber intraocular lens implantation in spherophakia.

    Science.gov (United States)

    Al-Haddad, Christiane; Khatib, Lama

    2012-07-01

    We describe a technique that uses the vitrector to perform successful lens aspiration and posterior chamber intraocular lens (IOL) implantation in children with spherophakia and anterior lens subluxation. After an anterior chamber maintainer is placed, the ocutome is introduced through a limbal incision to perform a circular vitrectorhexis to avoid excessive manipulation of the unstable lens followed by gentle cortex aspiration. A foldable IOL is injected into the sulcus (3-piece IOL) or bag (1-piece IOL) if the capsule is sufficiently stable. Through a pars plana incision, the ocutome is then used to perform a posterior capsulotomy to prevent late posterior capsule opacification. In our patient, sulcus IOL placement was more stable than in-the-bag placement. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  15. Characterization of Industrial Coolant Fluids and Continuous Ageing Monitoring by Wireless Node-Enabled Fiber Optic Sensors

    DEFF Research Database (Denmark)

    Sachat, Alexandros El; Meristoudi, Anastasia; Markos, Christos

    2017-01-01

    and spectroscopic characteristics of specific industrial-grade coolant fluids were analyzed along their entire life cycle range, and proper parameters for their efficient monitoring were identified. Based on multimode polymer or silica optical fibers, wide range (3-11) pH sensors were developed by employing sol...

  16. Femtosecond laser inscription of optical circuits in the cladding of optical fibers

    Science.gov (United States)

    Grenier, Jason R.

    The aim of this dissertation was to address the question of whether the cladding of single-mode fibers (SMFs) could be modified to enable optical fibers to serve as a more integrated, highly functional platform for optical circuit devices that can efficiently interconnect with the pre-existing fiber core waveguide. The approach adopted in this dissertation was to employ femtosecond laser direct writing (FLDW), an inherently 3D fabrication technique that harnesses non-linear laser-material interactions to modify the fused silica fiber cladding. A fiber mounting and alignment technique was developed along with oil-immersion focusing to address the strong aberrations caused by the cylindrical fiber shape. The development of real-time device monitoring during the FLDW was instrumental to overcome the acute coupling sensitivity to laser alignment errors of +/-1 ?m positional uncertainty, and thereby opened a new practical direction for the precise fabrication of optical devices inside optical fibers. These powerful and flexible laser fabrication and characterization techniques were successfully employed to optimize optical waveguiding devices positioned within the core and cladding of optical fibers. X-, S-Bend, and directional couplers were developed to enable efficient coupling between the laser-formed cladding devices and the pre-existing core waveguide, enabling up to 62% power transfer over bandwidths up to 300 nm at telecommunication wavelengths. Precise alignment of femtosecond laser modification tracks were positioned inside or near the core waveguide of SMFs was further shown to enable a flexible reshaping of the optical properties to create multimode guiding sections arbitrarily along the fiber length. This core waveguide modification facilitated the precise formation of multimode interferometers along the core waveguide to precisely tailor the modal profiles, and control the spectral and polarization response. In-fiber multimode interference (MMI) splitters

  17. Solar powered desalination system using Fresnel lens

    Science.gov (United States)

    Sales, M. T. B. F.

    2016-11-01

    The Philippines is surrounded by coastal areas and these areas can be a potential source for potable water. This study aims to design and construct a solar powered desalination system using Fresnel lens. The experimental study was conducted using polluted salt water for the sample and desalination was carried out using the designed system. The desalination system was composed of the solar concentrator, solar still and the condenser system. The Fresnel lens was made of acrylic plastic and was an effective solar concentrator. Solar stills made of dark colored glass bottles were effective in absorbing the solar energy. The condenser system made of polybutylene and polystyrene were effective in condensing the vapor at ambient temperature. The shortest time of vaporization of the salt water was at 293 sec and the optimum angle of position of the lens was 36.42°. The amount of condensate collected was directly proportional to the amount of salt water in the solar still. The highest mean efficiency of the designed set-up was 34.82%. The water produced by the solar powered desalination system using Fresnel lens passed the standards set by WHO (World Health Organization) for drinking water.

  18. Electronic states in a quantum lens

    International Nuclear Information System (INIS)

    Rodriguez, Arezky H.; Trallero-Giner, C.; Ulloa, S. E.; Marin-Antuna, J.

    2001-01-01

    We present a model to find analytically the electronic states in self-assembled quantum dots with a truncated spherical cap (''lens'') geometry. A conformal analytical image is designed to map the quantum dot boundary into a dot with semispherical shape. The Hamiltonian for a carrier confined in the quantum lens is correspondingly mapped into an equivalent operator and its eigenvalues and eigenfunctions for the corresponding Dirichlet problem are analyzed. A modified Rayleigh-Schro''dinger perturbation theory is presented to obtain analytical expressions for the energy levels and wave functions as a function of the spherical cap height b and radius a of the circular cross section. Calculations for a hard wall confinement potential are presented, and the effect of decreasing symmetry on the energy values and eigenfunctions of the lens-shape quantum dot is studied. As the degeneracies of a semicircular geometry are broken for b≠a, our perturbation approach allows tracking of the split states. Energy states and electronic wave functions with m=0 present the most pronounced influence on the reduction of the lens height. The method and expressions presented here can be straightforwardly extended to deal with more general Hamiltonians, including strains and valence-band coupling effects in Group III--V and Group II--VI self-assembled quantum dots

  19. Surgical treatment of hereditary lens subluxations.

    Science.gov (United States)

    Ozdek, Sengul; Sari, Ayca; Bilgihan, Kamil; Akata, Fikret; Hasanreisoglu, Berati

    2002-01-01

    To evaluate the effectiveness and results of pars plana vitreolensectomy approach with transscleral fixation of intraocular lens in hereditary lens subluxations. Fifteen eyes of 9 consecutive patients with a mean age of 12.8+/-6.2 years (6-26 years) with hereditary lens subluxation were operated on and the results were evaluated in a prospective study. Surgery was considered if best spectacle corrected visual acuity (BSCVA) was less than 20/70. All eyes underwent a 2-port pars plana vitreolensectomy and transscleral fixation of an intraocular lens (IOL). The mean follow-up period was 12.6+/-7.5 months (6-22 months). There was no major intraoperative complication. Preoperatively, 8 eyes (53.3%) had a BSCVA of counting fingers (CF) and 7 eyes (46.6%) had a BSCVA of 20/200 to 20/70. Postoperatively, 14 eyes (93.3%) had a BSCVA of 20/50 or better. None of the patients had IOL decentration or intraocular pressure (IOP) increase during the follow-up period. There was a macular hole formation in 1 eye postoperatively. The early results of pars plana vitreolensectomy with IOL implantation using scleral fixation technique had shown that it not only promises a rapid visual rehabilitation but it is also a relatively safe method. More serious complications, however, may occur in the long term.

  20. READING SCRIPTURE THROUGH A MYSTICAL LENS

    African Journals Online (AJOL)

    Reading scripture through a mystical lens. 144 the illuminatory function of scripture which confirms and explains experience, rather than in its philological or scientific status. Elisabeth often juxtaposes several texts when quoting from memory and the biblical foundation of her writings is clearly evident in certain cases which ...