WorldWideScience

Sample records for lens implants phototoxic

  1. Operating microscope light-induced phototoxic maculopathy after transscleral sutured posterior chamber intraocular lens implantation.

    Science.gov (United States)

    Kweon, Eui Yong; Ahn, Min; Lee, Dong Wook; You, In Cheon; Kim, Min Jung; Cho, Nam Chun

    2009-01-01

    The purpose of this study is to report the features of operating microscope light-induced retinal phototoxic maculopathy after transscleral sutured posterior chamber intraocular lens (TSS PC-IOL) implantation. The charts of 118 patients who underwent TSS PC-IOL implantation surgery at Chonbuk National University Hospital (Jeonju, Korea) between March 1999 and February 2008 were retrospectively reviewed. Fourteen patients underwent combined 3-port pars plana vitrectomy and TSS PC-IOL implantation (vitrectomy group), and 104 patients underwent TSS PC-IOL implantation only (nonvitrectomy group). All surgeries were performed under the same coaxial illuminated microscope. All diagnoses were confirmed through careful fundus examination and fluorescein angiography (FA). Diagnoses of retinal phototoxic maculopathy were established in 10 (8.47%) of 118 TSS PC-IOL implantation cases. Phototoxic maculopathy occurred more frequently in the vitrectomy group than in the nonvitrectomy group (6/14 versus 4/104, respectively; P microscope light-induced retinal phototoxic maculopathy can occur more frequently after TSS PC-IOL implantation than after casual cataract surgery, especially when TSS PC-IOL is combined with vitrectomy surgery. Surgeons should take precautions to prevent retinal phototoxicity after TSS PC-IOL implantation and vitrectomy.

  2. Phototoxicity and cytotoxicity of fullerol in human lens epithelial cells

    International Nuclear Information System (INIS)

    Roberts, Joan E.; Wielgus, Albert R.; Boyes, William K.; Andley, Usha; Chignell, Colin F.

    2008-01-01

    The water-soluble, hydroxylated fullerene [fullerol, nano-C 60 (OH) 22-26 ] has several clinical applications including use as a drug carrier to bypass the blood ocular barriers. We have assessed fullerol's potential ocular toxicity by measuring its cytotoxicity and phototoxicity induced by UVA and visible light in vitro with human lens epithelial cells (HLE B-3). Accumulation of nano-C 60 (OH) 22-26 in the cells was confirmed spectrophotometrically at 405 nm and cell viability estimated using MTS and LDH assays. Fullerol was cytotoxic to HLE B-3 cells maintained in the dark at concentrations higher than 20 μM. Exposure to either UVA or visible light in the presence of > 5 μM fullerol-induced phototoxic damage. When cells were pretreated with non-toxic antioxidants: 20 μM lutein, 1 mM N-acetyl cysteine, or 1 mM L-ascorbic acid prior to irradiation, only the singlet oxygen quencher-lutein significantly protected against fullerol photodamage. Apoptosis was observed in lens cells treated with fullerol whether or not the cells were irradiated, in the order UVA > visible light > dark. Dynamic light scattering (DLS) showed that in the presence of the endogenous lens protein α-crystallin, large aggregates of fullerol were reduced. In conclusion, fullerol is both cytotoxic and phototoxic to human lens epithelial cells. Although the acute toxicity of water-soluble nano-C 60 (OH) 22-26 is low, these compounds are retained in the body for long periods, raising concern for their chronic toxic effect. Before fullerols are used to deliver drugs to the eye, they should be tested for photo- and cytotoxicity in vivo

  3. Ultraviolet-B phototoxicity and hypothetical photomelanomagenesis: intraocular and crystalline lens photoprotection.

    Science.gov (United States)

    Mainster, Martin A; Turner, Patricia L

    2010-04-01

    Ultraviolet-B (UV-B) radiation can cause phototoxic macular injuries in young people who have been sunbathing but not sungazing and in welders. Welders have a reportedly increased risk of uveal melanoma. We analyze phakic and pseudophakic risks for solar and welding arc UV-B exposure. Optical radiation measurement, analysis, and perspective. Spectral transmittances were measured for UV-transmitting, UV-blocking, and blue-blocking intraocular lenses (IOLs). The photoprotective performances of crystalline and intraocular lenses were analyzed using relevant epidemiologic and laboratory data and action spectra for acute retinal phototoxicity and melanoma photocarcinogenesis. Crystalline lens UV-B retinal protection is deficient in children and young adults, increasing their potential susceptibility to acute retinal phototoxicity and hypothetical photomelanomagenesis. UV-B radiation has sufficient energy/photon to induce primary melanomagenic DNA lesions, unlike blue light or UV-A radiation. UV-blocking and blue-blocking IOLs have negligible UV-B transmittance. UV-transmitting IOL transmittance of UV-B radiation is equivalent to that of a 15-year-old crystalline lens. If optical radiation exposure is responsible for welders' increased risk of uveal melanoma, then UV-B radiation is the most probable causative agent and spectacle wear is a potential confounding factor in epidemiologic studies of ocular melanoma. Welders under 30 years of age are at greater risk for welding maculopathy than older welders. Children, adults under 30 years of age, and pseudophakic individuals with UV-transmitting IOLs should wear sunglasses in bright environments because of the UV-B window in their crystalline lenses or IOLs. Copyright 2010 Elsevier Inc. All rights reserved.

  4. Primary intraocular lens implantation for penetrating lens trauma in Africa.

    Science.gov (United States)

    Bowman, R J; Yorston, D; Wood, M; Gilbert, C; Foster, A

    1998-09-01

    This study aimed to audit the surgical strategy of primary posterior chamber intraocular lens implantation for cases of recent penetrating trauma involving the lens in an African population. Retrospective, noncomparative case series. Seventy-two cases are reported, including all patients who underwent primary intraocular lens implantation for traumatic cataract extraction performed within 1 month of injury between 1988 and 1996. Demographic characteristics and follow-up attendance rates are analyzed. Surgical technique and the occurrence of intraoperative and postoperative complications are reported. Visual outcomes are reported with detailed analysis for cases of poor visual outcome. Mean age was 14.3 years (standard deviation = 11.1), 57 (79%) were male and 15 (21%) were female (chi-square = 23.66, P capsule had been breached by the trauma in 27 (38%) cases, and 15 of these required anterior vitrectomy. Capsular fixation of the implant was achieved in 49% of patients, the remainder having sulcus fixation. Intraoperative rupture of the posterior capsule occurred in four cases. The only common postoperative complication was acute fibrinous anterior uveitis, which occurred in 29 (40%) patients, and 32% of patients followed up for at least 6 months required secondary posterior capsulotomy. This was more common in younger patients (chi-square = 4.2, P < 0.05). Corrected postoperative visual acuities were available for 51 patients, of which 71% achieved 20/60 or better visual acuity. Patients 6 years of age or younger were less likely to achieve 20/60 (chi-square = 6.61, P = 0.01). This surgical strategy has proved successful, producing good visual results and causing no sight-threatening complications. Primary posterior capsulotomy may be appropriate for younger patients.

  5. Intraocular lens implantation in microphthalmic patients.

    Science.gov (United States)

    Sinskey, R M; Amin, P; Stoppel, J

    1992-09-01

    Microphthalmos is a developmental disorder of the eye consisting of a smaller than normal eye. This disorder can present as an isolated condition or associated with other systemic alterations. It is not uncommon for patients with microphthalmos to have congenital cataracts along with other ocular and systemic abnormalities. This paper reports the experience with 11 microphthalmic eyes of seven patients who had primary or secondary intraocular lens (IOL) implantation over a six-year period from 1985 to 1991. In all cases the IOL had a 13.5 mm or 14.0 mm overall diameter and a 6.0 mm or 6.5 mm optic. It was difficult to obtain documentation of objective visual improvement in many of these cases because of the associated nystagmus. However, all patients reported subjective improvements. These results suggest that with proper technique and lens selection microphthalmic patients should be considered for IOL implantation with relative safety and success.

  6. Analysis of phakic before intraocular lens implantation for fundus examination

    OpenAIRE

    Juan Chen; Zhong-Ping Chen; Rui-Ling Zhu

    2014-01-01

    AIM:To investigate the findings of the eyes which were examined preoperatively by three mirror contact lens before the implantation of implantable collamer lens(ICL). To analysis the retinal pathological changes and to explore the clinical analysis of early diagnosis and treatment in retinopathy on fundus examination before operation. METHODS:The retrospective case series study included 127 eyes of 64 patients who underwent phakic intraocular lens implantation were received the fundus examina...

  7. [Phacoemulsification of subluxated lens with capsular tension ring implantation].

    Science.gov (United States)

    Dorecka, Mariola; Rokicki, Wojciech; Nita, Malgorzata; Krysik, Katarzyna; Nita, Ewa; Sikorska, Aleksandra; Romaniuk, Wanda

    2007-01-01

    To evaluate long term results of phacoemulsification with PC IOL and capsular tension ring (CTR) implantation in lens subluxation. The study comprised of 134 patients--146 eyes with subluxated lens. In all cases phacoemulsification with PC IOL and CTR implantation was performed. No intaroperative complications has occured. Postoperative complications included: inflammation in the anterior chamber in 3 eyes (2.1%), retinal detachment in 2 eyes (1.4%). In all cases there was no PC IOL decentration. (1) CTR facilitates phacoemulsification with PC IOL implantation in lens subluxation. (2) Phacoemulsification of subluxated lens with PC IOL and CTR implantation seems to be safe and effective procedure.

  8. Septic lens implantation syndrome in a cat.

    Science.gov (United States)

    Dalesandro, Nicole; Stiles, Jean; Miller, Margaret

    2011-09-01

    A 13-year-old female spayed domestic shorthair cat was presented initially for a change in the appearance of the left eye. On initial examination, a small penetrating wound was suspected as the cause for a corneal scar, an anterior cortical incipient cataract and mild iritis. The cat was not re-presented until 1 year later at which time ocular pain was marked. Severe anterior uveitis and glaucoma were diagnosed and the eye enucleated. Histopathology documented intralenticular coccoid bacteria and septic lens implantation syndrome. © 2011 American College of Veterinary Ophthalmologists.

  9. Initial Experience With Posterior Chamber Intraocular Lens Implant ...

    African Journals Online (AJOL)

    The results of extracapsular cataract extraction with posterior chamber intraocular lens implant at the Jos University Teaching Hospital are reviewed. The results suggest that despite lack of facilities to calculate the lens power for emmetropia, the use of a standard lens of about 19.0D will provide a good number of our ...

  10. Cataract surgery with intraocular lens implantation in children aged ...

    African Journals Online (AJOL)

    Cataract surgery with intraocular lens implantation in children aged 5-15 in local anaesthesia: visual outcomes and complications. ... The mean implanted IOL power was 22.01 ±3.16 D. IOL was succefuly implanted in 54 eyes (87.07%). Eight eyes (9.67%) were left aphakic. Increase in BCVA of 4 logMAR lines and above ...

  11. Retinal images in the human eye with implanted intraocular lens

    Science.gov (United States)

    Zając, Marek; Siedlecki, Damian; Nowak, Jerzy

    2007-04-01

    A typical proceeding in cataract is based on the removal of opaque crystalline lens and inserting in its place the artificial intraocular lens (IOL). The quality of retinal image after such procedure depends, among others, on the parameters of the IOL, so the design of the implanted lens is of great importance. An appropriate choice of the IOL material, especially in relation to its biocompatibility, is often considered. However the parameter, which is often omitted during the IOL design is its chromatic aberration. In particular lack of its adequacy to the chromatic aberration of a crystalline lens may cause problems. In order to fit better chromatic aberration of the eye with implanted IOL to that of the healthy eye we propose a hybrid - refractive-diffractive IOL. It can be designed in such way that the total longitudinal chromatic aberration of an eye with implanted IOL equals the total longitudinal chromatic aberration of a healthy eye. In this study we compare the retinal image quality calculated numerically on the basis of the well known Liou-Brennan eye model with typical IOL implanted with that obtained if the IOL is done as hybrid (refractive-diffractive) design.

  12. Spontaneous Rotation of a Toric Implantable Collamer Lens

    OpenAIRE

    Navas, Alejandro; Mu?oz-Ocampo, Mayeli; Graue-Hern?ndez, Enrique O.; G?mez-Bastar, Arturo; Ramirez-Luqu?n, Tito

    2010-01-01

    We present a case of toric implantable collamer lens (TICL) spontaneous rotation in a patient with myopic astigmatism. A 23-year-old female underwent TICL implantation. Preoperative uncorrected visual acuity (UCVA) was 20/800 and 20/1200, respectively, with –7.75 –4.25 × 0° and –8.25 –5.25 × 180°. The left eye achieved an UCVA of 20/30. After 3 months of successful implantation of TICL in the left eye, the patient presented with a sudden decrease in visual acuity in the left eye. UCVA was 20/...

  13. Phacoemulsification and intraocular lens implantation in patients with oculocutaneous albinism.

    Science.gov (United States)

    Dávila, Pedro J; Ulloa-Padilla, Jan P; Izquierdo, Natalio J

    2017-01-01

    To evaluate the benefits of phacoemulsification and intraocular lens implantation in patients with oculocutaneous albinism (OCA). The charts of 195 patients with OCA who visited a local eye clinic were reviewed. All of these patients had genetic linkage analysis to establish OCA type. Frequencies and Paired t-test analysis were determined. Of the 195 patients, nine (4.6%) underwent clear cornea phacoemulsification with intraocular lens implantation. Seven of the nine patients with OCA had the Hermansky-Pudlak (HPS) type 1; two had OCA type 1. Pre-operative BCVA of all eyes ranged from 1.0 to 2.3 logMAR with a mean of 1.42 logMAR and a standard deviation of 0.41 logMAR. Post-operative BCVA of all eyes ranged from 1.0 to 1.30 logMAR with a mean of 1.04 logMAR and a standard deviation of 0.10 logMAR. BCVA improved after phacoemulsification surgery and intraocular lens implantation (p = 0.002). Pre-operative astigmatism of all eyes ranged from +0.50 to +5.75 with a mean of +2.25 and a standard deviation of +2.40. Post-operative astigmatism of all eyes ranged from +0.50 to +2.00 with a mean of +1.23 and a standard deviation of +0.42. Astigmatism improved after phacoemulsification surgery and intraocular lens implantation (p = 0.05). Nine patients with OCA who underwent phacoemulsification and intraocular lens implant experienced improved visual acuity and reduced astigmatism post-operatively. These results suggest cataract surgery may improve vision and refractive errors, and thus quality of life, in patients with albinism.

  14. Vitrectorhexis and lens aspiration with posterior chamber intraocular lens implantation in spherophakia.

    Science.gov (United States)

    Al-Haddad, Christiane; Khatib, Lama

    2012-07-01

    We describe a technique that uses the vitrector to perform successful lens aspiration and posterior chamber intraocular lens (IOL) implantation in children with spherophakia and anterior lens subluxation. After an anterior chamber maintainer is placed, the ocutome is introduced through a limbal incision to perform a circular vitrectorhexis to avoid excessive manipulation of the unstable lens followed by gentle cortex aspiration. A foldable IOL is injected into the sulcus (3-piece IOL) or bag (1-piece IOL) if the capsule is sufficiently stable. Through a pars plana incision, the ocutome is then used to perform a posterior capsulotomy to prevent late posterior capsule opacification. In our patient, sulcus IOL placement was more stable than in-the-bag placement. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  15. Analysis of phakic before intraocular lens implantation for fundus examination

    Directory of Open Access Journals (Sweden)

    Juan Chen

    2014-10-01

    Full Text Available AIM:To investigate the findings of the eyes which were examined preoperatively by three mirror contact lens before the implantation of implantable collamer lens(ICL. To analysis the retinal pathological changes and to explore the clinical analysis of early diagnosis and treatment in retinopathy on fundus examination before operation. METHODS:The retrospective case series study included 127 eyes of 64 patients who underwent phakic intraocular lens implantation were received the fundus examination by three mirror from April 2011 to April 2012 in our hospital. The age, refractive diopter, the findings of Goldmann three mirror examination and the condition of retinal photocoagulation were analysed and concluded.RESULTS: A total of 34 eyes(26.8%out of all 127 eyes(64 caseswere found to have peripheral retinal pathological changes. Eight eyes(6.3%with retinal holes, 15 eyes(11.8%with retinal lattice degeneration, 5 eyes(3.9%with retina cream degeneration, 3 eyes(2.4%with retinal paving stone degeneration,2 eyes with vitreoretinal adhesion and traction,1 eye(0.8%with retinal hemorrhage. Twenty-five cases were given retinal photocoagulation and then received the ICL implantation after 3mo. The follow-up time was 1a. No retinal detachment happened.CONCLUSION:Phakic before intraocular lens implantation for fundus examination by three mirror is contributed to find the peripheral retinal pathological changes and abnormity. And make the appropriate treatment before operation for improving the security of operation, it can also give help to the postoperative follow-up of the fundus of these patients.

  16. Sutureless Intrascleral Fixated Intraocular Lens Implantation.

    Science.gov (United States)

    Karadag, Remzi; Celik, Haci Ugur; Bayramlar, Huseyin; Rapuano, Christopher J

    2016-08-01

    To review sutureless intrascleral intraocular lens (IOL) fixation methods. Review of published literature. Sutureless intrascleral IOL fixation methods are newer and have been developed to eliminate the suture-related complications of sutured scleral fixation methods such as suture-induced inflammation or infection and IOL dislocation or subluxation due to suture degradation or suture breakage. Sutureless intrascleral fixation methods aim for intrascleral haptic fixation to achieve stability of the IOL. Various methods of sutureless scleral fixation have been described. Using a needle, a blade, or a trochar, sclerostomies are created in all techniques for intraocular access. Some surgeons prefer to create scleral tunnels, whereas others use scleral flaps for scleral fixation of haptics. The stability of IOLs is attained by the scar tissue formed around the haptics. Short-term results of these new methods are acceptable; studies including more cases with longer follow-up are needed to determine their long-term success. [J Cataract Refract Surg. 2016;32(9):586-597.]. Copyright 2016, SLACK Incorporated.

  17. Toric implantable collamer lens for keratoconus

    Directory of Open Access Journals (Sweden)

    Mathew Kurian Kummelil

    2013-01-01

    Full Text Available Keratoconus is a progressive non-inflammatory thinning of the cornea that induces myopia and irregular astigmatism and decreases the quality of vision due to monocular diplopia, halos, or ghost images. Keratoconus patients unfit for corneal procedures and intolerant to refractive correction by spectacles or contact lenses have been implanted toric posterior chamber phakic intraocular lenses (PC pIOLs alone or combined with other surgical procedures to correct the refractive errors associated with keratoconus as an off label procedure with special informed consent from the patients. Several reports attest to the safety and efficacy of the procedure, though the associated corneal higher order aberrations would have an impact on the final visual quality.

  18. Outcomes of Sutureless Iris-Claw Lens Implantation.

    Science.gov (United States)

    Choragiewicz, Tomasz; Rejdak, Robert; Grzybowski, Andrzej; Nowomiejska, Katarzyna; Moneta-Wielgoś, Joanna; Ozimek, Małgorzata; Jünemann, Anselm G M

    2016-01-01

    Purpose. To evaluate the indications, refraction, and visual and safety outcomes of iris-claw intraocular lens implanted retropupillary with sutureless technique during primary or secondary operation. Methods. Retrospective study of case series. The Haigis formula was used to calculate intraocular lens power. In all cases the wound was closed without suturing. Results. The study comprised 47 eyes. The mean follow-up time was 15.9 months (SD 12.2). The mean preoperative CDVA was 0.25 (SD 0.21). The final mean CDVA was 0.46 (SD 0.27). No hypotony or need for wound suturing was observed postoperatively. Mean postoperative refractive error was -0.27 Dsph (-3.87 Dsph to +2.85 Dsph; median 0.0, SD 1.28). The mean postoperative astigmatism was -1.82 Dcyl (min -0.25, max -5.5; median -1.25, SD 1.07). Postoperative complications were observed in 10 eyes. The most common complication was ovalization of the iris, which was observed in 8 eyes. The mean operation time was 35.9 min (min 11 min, max 79 min; median 34, SD 15.4). Conclusion. Retropupilary iris-claw intraocular lens (IOL) implantation with sutureless wound closing is an easy and fast method, ensuring good refractive outcome and a low risk of complication. The Haigis formula proved to be predictable in postoperative refraction.

  19. Outcomes of Sutureless Iris-Claw Lens Implantation

    Directory of Open Access Journals (Sweden)

    Tomasz Choragiewicz

    2016-01-01

    Full Text Available Purpose. To evaluate the indications, refraction, and visual and safety outcomes of iris-claw intraocular lens implanted retropupillary with sutureless technique during primary or secondary operation. Methods. Retrospective study of case series. The Haigis formula was used to calculate intraocular lens power. In all cases the wound was closed without suturing. Results. The study comprised 47 eyes. The mean follow-up time was 15.9 months (SD 12.2. The mean preoperative CDVA was 0.25 (SD 0.21. The final mean CDVA was 0.46 (SD 0.27. No hypotony or need for wound suturing was observed postoperatively. Mean postoperative refractive error was −0.27 Dsph (−3.87 Dsph to +2.85 Dsph; median 0.0, SD 1.28. The mean postoperative astigmatism was −1.82 Dcyl (min −0.25, max −5.5; median −1.25, SD 1.07. Postoperative complications were observed in 10 eyes. The most common complication was ovalization of the iris, which was observed in 8 eyes. The mean operation time was 35.9 min (min 11 min, max 79 min; median 34, SD 15.4. Conclusion. Retropupilary iris-claw intraocular lens (IOL implantation with sutureless wound closing is an easy and fast method, ensuring good refractive outcome and a low risk of complication. The Haigis formula proved to be predictable in postoperative refraction.

  20. Optical quality of toric intraocular lens implantation in cataract surgery

    Directory of Open Access Journals (Sweden)

    Xian-Wen Xiao

    2015-02-01

    Full Text Available AIM: To analyze the optical quality after implantation of toric intraocular lens with optical quality analysis system. METHODS: Fifty-two eyes of forty-four patients with regular corneal astigmatism of at least 1.00 D underwent implantation of AcrySof toric intraocular lens, including T3 group 19 eyes, T4 group 18 eyes, T5 group 10 eyes, T6 group 5 eyes. Main outcomes evaluated at 3mo of follow-up, included uncorrected distance visual acuity (UDVA, corrected distance visual acuity (CDVA, residual refractive cylinder and intraocular lens (IOL axis rotation. Objective optical quality were measured using optical quality analysis system (OQAS Ⅱ®, Visiometrics, Spain, included the cutoff frequency of modulation transfer function (MTFcutoff, objective scattering index (OSI, Strehl ratio, optical quality analysis system value (OV 100%, OV 20% and OV 9% [the optical quality analysis system (OQAS values at contrasts of 100%, 20%, and 9%]. RESULTS: At 3mo postoperative, the mean UDVA and CDVA was 0.18±0.11 and 0.07±0.08 logMAR; the mean residual refractive cylinder was 0.50±0.29 D; the mean toric IOL axis rotation was 3.62±1.76 degrees, the mean MTFcutoff, OSI, Strehl ratio, OV 100%, OV 20% and OV 9% were 22.862±5.584, 1.80±0.84, 0.155±0.038, 0.76±0.18, 0.77±0.19 and 0.78±0.21. The values of UDVA, CDVA, IOL axis rotation, MTFcutoff, OSI, Strehl ratio, OV100%, OV20% and OV9% depending on the power of the cylinder of the implantation were not significantly different (P>0.05, except the residual refractive cylinder (PCONCLUSION: The optical quality analysis system was useful for characterizing the optical quality of AcrySof toric IOL implantation. Implantation of an AcrySof toric IOL is an effective and safe method to correct corneal astigmatism during cataract surgery.

  1. [Intraocular lens implantation with one loop haptic amputated: a new propose to the subluxation lens surgical treatment].

    Science.gov (United States)

    Ventura, Marcelo; Endriss, Daniela

    2010-01-01

    To evaluate the postoperative results of congenital lens subluxation corrected by a new technique. Retrospective chart review of 21 eyes of 13 patients with no traumatic lens subluxation who underwent surgery in Altino Ventura Foundation from April, 1999 to April, 2004. The mean age was 8.7 +/- 5.4 years old, and the mean follow-up period was 21.5 +/- 19.3 months. Patients underwent phacoaspiration, endocapsular ring and intraocular lens (IOL) implantation. The implanted IOL had one loop haptic excised and was supported above the ring, inside the capsular bag promoting intraocular lens centralization. Visual acuity improvement was observed in all cases. There was a significant reduction of the spherical equivalent and spherical component comparing the pre and postoperative refraction (psubluxation surgical treatment, promoting lens centralization and postoperative visual acuity improvement.

  2. Refractive lens exchange and piggyback intraocular lens implantation in nanophthalmos: Visual and structural outcomes.

    Science.gov (United States)

    Mohebbi, Masoomeh; Fallah-Tafti, Mohammad-Reza; Fadakar, Kaveh; Katoozpour, Ramon; Mohammadi, Seyed-Farzad; Fallah-Tafti, Zahra; Khorami, Azita

    2017-09-01

    To evaluate the best piggyback intraocular lens (IOL) implantation method and the outcomes in nanophthalmos eyes and to define the postoperative structural changes. Farabi Eye Hospital, Tehran, Iran. Prospective case series. Candidates for refractive surgery who were nanophthalmic were recruited. Patients had refractive lens exchange followed by implantation of both IOLs in the bag or 1 IOL in the bag and 1 IOL in the sulcus. The baseline and follow-up visual acuity, refractive status, and structural Scheimpflug imaging were evaluated. Ultrasound biomicroscopy (UBM) was performed 6 months postoperatively. The study comprised 9 nanophthalmic patients (18 eyes) with a mean preoperative uncorrected distance visual acuity (UDVA) of 1.53 logarithm of the minimum angle of resolution (logMAR) ± 0.3 (SD), mean corrected distance visual acuity (CDVA) of 0.34 ± 0.2 logMAR, and mean spherical equivalent (SE) of +13.55 ± 4.0 diopters (D). The mean postoperative UDVA improved from baseline. There was no significant difference in the mean UDVA and CDVA between the 2 IOL groups. Postoperatively, both groups had a significant improvement in SE, a significant rise in anterior chamber depth and angle, and similar UBM measurements. Piggyback IOL implantation was an effective refractive procedure in nanophthalmic eyes. Both implantation methods resulted in similar outcomes; however, the small number of patients in each group made it less likely that possible differences would be found. The increase in angle values might help prevent the development of closed-angle glaucoma. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  3. A safe technique for in-the-bag intraocular lens implantation in pediatric cataract surgery.

    Science.gov (United States)

    Khokhar, Sudarshan; Sharma, Reetika; Patil, Bharat; Sinha, Gautam; Nayak, Bhagabat; Kinkhabwala, Ravish Akhilkumar

    2015-01-01

    To describe a safe technique for in-the-bag intraocular lens (IOL) implantation in pediatric cataract patients who undergo lens aspiration with primary posterior capsulorhexis and anterior vitrectomy. Sixty eyes of 45 consecutive patients with congenital/developmental cataract underwent lens aspiration with primary posterior continuous curvilinear capsulorhexis (PCCC) with anterior vitrectomy and in-the-bag IOL implantation using the described technique of IOL implantation using anterior capsule as support. All eyes had stable IOL at the end of surgery and none of the eyes had lens decentration/dislocation in posterior vitreous. Implantation of in-the-bag IOL is difficult in children who undergo primary PCCC with anterior vitrectomy. Our technique of implanting IOL by pushing it against the back surface of anterior capsule is a safe method and results in no complications related to faulty IOL implantation.

  4. Spontaneous Rotation of a Toric Implantable Collamer Lens

    Science.gov (United States)

    Navas, Alejandro; Muñoz-Ocampo, Mayeli; Graue-Hernández, Enrique O.; Gómez-Bastar, Arturo; Ramirez-Luquín, Tito

    2010-01-01

    We present a case of toric implantable collamer lens (TICL) spontaneous rotation in a patient with myopic astigmatism. A 23-year-old female underwent TICL implantation. Preoperative uncorrected visual acuity (UCVA) was 20/800 and 20/1200, respectively, with −7.75 −4.25 × 0° and −8.25 −5.25 × 180°. The left eye achieved an UCVA of 20/30. After 3 months of successful implantation of TICL in the left eye, the patient presented with a sudden decrease in visual acuity in the left eye. UCVA was 20/100 with a refraction of +2.50 −4.50 × 165°. We observed the toric marks with a 30° rotation from the original position and decided to reposition the TICL, obtaining a final UCVA of 20/25, which remained stable at 6 months' follow-up. TICL can present a considerable rotation that compromises visual acuity. The relocation of TICL is a safe and effective procedure to recover visual acuity due to significant spontaneous TICL rotation. PMID:21151633

  5. Spontaneous Rotation of a Toric Implantable Collamer Lens

    Directory of Open Access Journals (Sweden)

    Alejandro Navas

    2010-11-01

    Full Text Available We present a case of toric implantable collamer lens (TICL spontaneous rotation in a patient with myopic astigmatism. A 23-year-old female underwent TICL implantation. Preoperative uncorrected visual acuity (UCVA was 20/800 and 20/1200, respectively, with –7.75 –4.25 × 0° and –8.25 –5.25 × 180°. The left eye achieved an UCVA of 20/30. After 3 months of successful implantation of TICL in the left eye, the patient presented with a sudden decrease in visual acuity in the left eye. UCVA was 20/100 with a refraction of +2.50 –4.50 × 165°. We observed the toric marks with a 30° rotation from the original position and decided to reposition the TICL, obtaining a final UCVA of 20/25, which remained stable at 6 months’ follow-up. TICL can present a considerable rotation that compromises visual acuity. The relocation of TICL is a safe and effective procedure to recover visual acuity due to significant spontaneous TICL rotation.

  6. Correction effect of phakic posterior chamber implantable contact lens implantation on high myopia

    Directory of Open Access Journals (Sweden)

    Jing Wang

    2018-02-01

    Full Text Available AIM: To analyze the clinical efficacy of phakic posterior chamber implantable contact lens(ICLimplantation on high myopia patients. METHODS: Thirty-four patients(68 eyeswho checked and diagnosed as high myopia in our hospital from June 2014 to June 2015 were selected as the clinical research subjects, and all the patients were given phakic posterior chamber intraocular lens implantation treatment. The diopter, visual acuity recovery, central anterior chamber depth, corneal endothelial cell count, and intraocular pressure after treatment were observed. RESULTS: The equivalent spherical refraction, central anterior chamber depth, uncorrected visual acuity and best corrected visual acuity recovery at 1, 3 and 6mo, 1 and 2a after treatment were better than those before treatment, and the differences were statistically significant(PP>0.05. There were no significant differences in uncorrected visual acuity, best corrected visual acuity, equivalent spherical refraction and central anterior chamber depth at 1, 3mo and 1 and 2a after treatment(P>0.05. CONCLUSION: The application of phakic posterior chamber intraocular lens implantation for the treatment of high myopia patients can improve the equivalent spherical refraction and central anterior chamber depth, improve uncorrected visual acuity, meanwhile, it has less effect on the patient's intraocular pressure and corneal endometrial cells, the effect maintenance and safety is better which meet their expectations.

  7. [Evaluation of colour vision according to type of implanted artificial foldable intraocular lens].

    Science.gov (United States)

    Stopyra, Wiktor

    2012-01-01

    The aim of research was comparing the colour vision of patients with blue light filtering artificial lens to the patients with implant without blue light filter. 99 patients (120 eyes) divided on three groups were examined. 40 patients (40 eyes) after cataract surgery with implantation of blue light filtering lens were the first group. 39 patients (40 eyes) who had implanted lens without filter were the second group. 20 patients (40 eyes) with own transparent lens were the third group. Farnsworth-Munsell 100 Hue test was used in research. Each patient made test on thirtieth day after cataract surgery. Following average total error score (TES) values in groups were observed: the first group--60.66, the second group--83.71, the third group--61.55. Average axis of disorder in blue-yellow range was following: patients after cataract surgery with implantation of blue light filtering lens--5.48, patients with implant without blue light filter--7.28, control group--5.74. 1. Kind of artificial intraocular lens has meaning in colour vision at pseudophakic patients. 2. Blue light filter of artificial intraocular foldable lens advantageously effects perception of colours. 3. Lack of blue light filter in artificial intraocular lens gets worse colour vision especially in blue-yellow range.

  8. Results of Posterior Chamber Lens Implantation for Correction of Myopia

    Directory of Open Access Journals (Sweden)

    Pınar Sorgun Evcili

    2012-10-01

    Full Text Available Pur po se: To evaluate the results of posterior chamber phakic intraocular lens implantation in myopic patients. Ma te ri al and Met hod: Posterior chamber phakic intraocular lens (STAAR ICL implantation was performed in 58 eyes of 33 patients with mean spherical equivalent of -13.12±5.31 diopters (D (-2.5 - -24.75 D between August 2007 and October 2010 at Dr. Lütfi Kırdar Kartal Training and Research Hospital, Second Eye Clinic. The mean age of the patients was 32.84 ± 9.95 years (18-55 years - 24 (72.7% were male and 9 (27.3% were female. The study was designed as prospective case series. The patients were evaluated regarding visual acuity, refraction, endothelial cell count, and complications in postoperative period. Re sults: The mean follow-up time was 21.5±4.9 (12-24 months months. The mean spherical equivalent was -1.29±1.53 D (-5.6 D - +2.60 D at the last postoperative follow-up visit. Visual acuity was better or equal to preoperative best-corrected value in 42 (72.4% of eyes at the last follow-up visit postoperatively. Mean spherical equivalent was regressed to -1.13±1.59D at 1-month and -1.39±1.53D at 24-month postoperative follow-up visit. Pupillary-block glaucoma in 1 eye (1.7%, anterior subcapsular opacification not affecting the vision in 4 eyes, and retinal detachment in 1 eye were detected at follow-up visits. Dis cus si on: ICL implantation was observed to be an effective and safe method for correction of myopia in two-year follow-up. As possible retinal complications may develop, the patients must be followed carefully during the preoperative and postoperative period. (Turk J Ophthalmol 2012; 42: 349-54

  9. Comparison of Two Intraocular Lens Implantation Techniques in Pediatric Cataract Surgery in Terms of Postoperative Complications

    Directory of Open Access Journals (Sweden)

    Mustafa Erdoğan Cicik

    2018-03-01

    Full Text Available Background: Pediatric cataract surgery differs substantially from adult cataract surgery. Numerous studies have focused on reducing the development of postoperative complications. Aims: To compare two intraocular lens implantation techniques used in pediatric cataract surgery in terms of postoperative complications. Study Design: Case-control study. Methods: Patients who underwent pediatric cataract surgery and intraocular lens implantation between 2008 and 2016 were evaluated in this retrospective study. Patients aged 3-15 years with unilateral or bilateral cataract and without corneal pathology were included in the study. The patients were categorized into the following two groups: those who underwent posterior capsulorhexis and anterior vitrectomy using in-the-bag intraocular lens implantation (group 1 and those who underwent posterior capsulorhexis and intraocular lens implantation with the optic fixed behind the posterior capsulorhexis (group 2. Rates of postoperative visual axis opacification and complications (glaucoma, posterior synechiae, uveitic reaction, and intraocular lens decentration were evaluated in these groups. The implanted intraocular lenses were either monoblock (AcrySof SN60AT intraocular lens, triple-piece (AcrySof MA60BM intraocular lens foldable hydrophobic acrylic lenses, or multifocal lenses (AcrySof IQ ReSTOR. Results: This retrospective study included 52 eyes of 37 patients. Group 1 comprised 26 eyes of 20 patients and group 2 comprised 26 eyes of 17 patients. During the follow-up, visual axis opacification was observed in two patients in group 1 but no patients in group 2. Regarding postoperative complications, there was no uveitic reaction, posterior synechiae, or intraocular lens decentration in either group. There was no significant difference between the groups in terms of the postoperative complications (p>0.05. Conclusion: There was no significant difference between in-the-bag intraocular lens implantation

  10. Clinical observation of capsular tension ring implantation in congenital lens subluxation treating by phacoemulsification

    OpenAIRE

    Liang-Nan Sun; Bai-Jun Li; Yuan-Fei Zhu; Xin-Hua Liu

    2017-01-01

    AIM: To evaluate the clinical results of capsular tension ring(CTR)implantation in phacoemulsification for eyes with congenital lens subluxation. METHODS: This study comprised 18 patients(31 eyes)with congenital ectopia lentis. All patients received phacoemulsification with CTR and intraocular lens(IOL)implantation. Visual acuity before and after surgery were examined. IOL decentration were measured with Image-Pro Plus image processing software. The complications were also recorded preoperati...

  11. [Visual quality comparison after multifocal toric intraocular lens or monofocal toric intraocular lens implantation].

    Science.gov (United States)

    Feng, K; Guo, H K; Zhang, Y L; Wu, Z

    2017-04-11

    Objective: To compare visual quality and satisfaction after multifocal toric intraocular lens (Acrysof IQ Restor toric, ART) and monofocal toric intraocular lens implantation in patients. Methods: It was a prospective nonrandomized Phase Ⅲ clinical trial. Patients with age-related cataract and corneal astigmatism were enrolled and accepted phacoemulsification combined with implantation of intraocular lens (IOL) in Henan Provincial Eye Hospital during March 2013 to December 2014. Fifty-six cases were divided into two groups according to which IOL they chose. ART group included 28 cases (3l eyes) aged from 41.0 to 72.0 years, with an average age of 61.5 years; toric group included 28 cases (33 eyes) aged from 42.0 to 75.0 years, with an average age of 63.5 years. Three months postoperatively, uncorrected distance visual acuity (UDVA) at 5, 70, 40 cm, corrected distance, intermediate, and near visual acuities, defocus curve, residual refractive astigmatism, rotational stability of the IOL, contrast sensitivity and patientsatisfaction were evaluated. All data were processed by statistic package deal SPSS 16.0. Postoperative visual acuity, residual astigmatism, IOL axial rotation and contrast sensitivity were compared by independent samples t test; preoperative and postoperative corneal astigmatism were compared by paired t -test; spectacle independency and halo incidence were processed by χ(2) test; visual satisfaction score was analyzed by Mann-Whitney test. Results: At 3 months postoperatively, in ART group, UDVA was (0.04±0.05), UIVA was (0.24±0.15), UNVA was (0.20±0.24). While in Toric group, UDVA was (0.06±0.04), UIVA was (0.30±0.13), UNVA was (0.47±0.21). There was no significant difference in UDVA between two groups( t= 0.79, P= 0.433). But in ART group, UIVA and UNVA were markedly better than those in Toric group( t= 2.74, P= 0.008; t= 3.45, PART group and 2.50 D (+1.00--1.50 D) in the Toric group. Average postoperative residual astigmatism was (-0.45

  12. IOL Implants: Lens Replacement and Cataract Surgery (Intraocular Lenses)

    Science.gov (United States)

    ... Cataract Surgery vs. Laser-Assisted Cataract Surgery Cataract Vision Simulator Cataract Pictures and Videos: What Do ... Mar. 27, 2018 An intraocular lens (or IOL) is a tiny, artificial lens for the eye. It replaces the eye's ...

  13. Phototoxicity and photoallergy.

    Science.gov (United States)

    Epstein, J H

    1999-12-01

    Photosensitivity may be phototoxic or photoallergic. Phototoxicity is much more common. There are 2 types of phototoxicity: photodynamic, which requires oxygen, and nonphotodynamic, which does not. Reactions induced by porphyrin molecules, coal tar derivatives, and many drugs are photodynamic. The reaction induced by psoralens, for the most part, is nonphotodynamic. Acute phototoxic reactions are characterized by erythema and edema followed by hyperpigmentation. Long-term ultraviolet phototoxicity results in chronic sun damage and skin cancer formation. Also, certain chemicals such as psoralen molecules and coal tar are photocarcinogenic. Phototoxic reactions to certain drugs produce unusual clinical patterns, that is lichenoid eruptions, dyschromia, photo-onycholysis, and pseudoporphyria. Photoallergy is an uncommon acquired altered reactivity dependent on an immediate antibody or a delayed cell mediated reaction. Solar urticaria is an example of the former, whereas photoallergy to exogenous chemicals is an example of the latter. Photoallergy to systemic drugs does occur but is difficult to characterize. The action spectrum for photoreactions to exogenous agents usually at least includes the ultraviolet A rays for both phototoxicity and photoallergy.

  14. Phakic iris-claw intraocular lens implantation for correction of high myopia with clear corneal incision

    Directory of Open Access Journals (Sweden)

    Lin Li

    2014-04-01

    Full Text Available AIM: To investigate the safety and therapeutic effectiveness of phakic iris-claw intraocular lens implantation for correction of high myopia with clear corneal incision. METHODS: Implantation of phakic iris-claw intraocular lens through clear corneal incision was performed on 28 eyes of 20 high myopic patients under topical anaesthesia. Intraoperative and postoperative complications, visual acuity, intraocular pressure, refractive diopter, corneal endothelium, the stable of intraocular lens and the turbid level of lens were observed. RESULTS: All cases were smoothly implanted iris-claw intraocular lens. No complications were found during the operation. The uncorrected visual acuity of post-operation was better than the best corrected visual acuity of pre-operation. The follow-up time lasted for 6mo, and the intraocular lens in all the eyes were basically in the normal position without tilting and obvious deviation. No serious complications such as cataract, uveitis, cystoid macular edema, retinal detachment were seen in all cases. CONCLUSION: On the basis of having adept microsurgery technology, phakic iris-claw intraocular lens implantation is predictable and stable, and post-operation visual acuity is satisfying with few complications. It is a safe and effective way to treat high myopia.

  15. Efficacy on chopping with lens loop-pad in the small incision extracapsular cataract surgery with intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Xiao-Ning Peng

    2014-04-01

    Full Text Available AIM: To study the clinical effects of chopping with lens loop-pad in the small incision extracapsular cataract surgery with intraocular lens implantation.METHODS:A total of 75 cases(80 eyes, in which loop-pad and chop knife were performed to chop nucleus before implanting intraocular lens. Visual acuity, postoperative astigmatism degree, intraoperative and postoperative complications were observed. The post-operative follow-up periods ranged from 3 to 12mo.RESULTS: The visual acuity was 0.3-0.5 in 37 eyes and 0.6 or better in 21 eyes at 1d, while was respectively in 43 eyes and in 26 eyes at 1mo. Compared with preoperative astigmatism(0.85±0.29D, there were significant difference at postoperative 1wk(1.75±0.55D(PP>0.05. Intraoperative posterior capsule rupture occurred in 4 eyes, which implantation was successful in 1 eye and 3 eyes was managed viaciliary sulcus. Two eyes had dermatoglyphic pattern edema in corneal endothelium which recovered after about 3d. Two eyes had local patchy opacities which recovered in 2wk. Two eyes had transient high intraocular pressure.CONCLUSION: The surgery is efficient, low cost, easy process and less complications, it is worth to be popularized.

  16. Clinical assessment of diclofenac sodium eye drops in toric intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Yan Luo

    2013-05-01

    Full Text Available AIM:To evaluate the application of diclofenac sodium eye drops in toric intraocular lens implantation. METHODS: From January 2011 to February 2012, 38 eyes of 37 patients, who underwent toric intraocular lens implantation in this hospital, were randomly divided into diclofenac sodium eye drops group(trial groupand control group. Patient's degree of cooperation during surgery and inflammation postoperation after 1 day, 3,7, days, 1 month and 3 months were evaluated. RESULTS: Patient's degree of cooperation during surgery in the trial group(1.53±0.62was significantly better than in the control group(2.40±0.88, P<0.05. Inflammation reaction was gentle in the trial group 1 day postoperatively. CONCLUSION: Diclofenac sodium eye drops used during toric intraocular lens implantation can obviously alleviate eye irritation, and increase the cooperation of patients.

  17. Results and complications of scleral fixated (Sutured posterior chamber intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Amoozadeh J

    2001-08-01

    Full Text Available Optical rehabilitation of the patient with aphakia who cannot tolerate contact lenses present a therapeutic challenge. In the absence of capsular support, anterior chamber lenses have been widely used. On the other hand intraocular lens implantation of scleral sutured posterior chamber intraocular lens during penterating keratoplasty or insufficient iris support is recommended. The purpose of this study is to evaluate the clinical outcome and complication in 17 patients who underwent scleral-fixation of an intraocular lens.We studied prospectively the results of posterior chamber intraocular lens implantation by scleral fixation in 17 eyes of 17 patients without a complete posterior lens capsule support at farabi Eye Hospital. Uncorrected visual acuity improved from counting finger to 20/40 or better in 9 eyes (53 percent. The following complications were observed during the mean postoperative follow-up of 7.2 (range 3-12 months; increased intraocular pressure in 5 eyes, vitreous hemorrhage and icr hyphema in 2 eyes, cystoid macular edema (CME and vitritis in one eye, and endophthalmitis and retinal detachment in one eye. Posterior chamber intraocular lens implantation by scleral fixation is a relatively safe procedure and can be recommended for many patients

  18. Axis alignment and rotational stability after implantation of the toric implantable collamer lens for myopic astigmatism.

    Science.gov (United States)

    Hashem, Ayman N; El Danasoury, Alaa M; Anwar, Hamed M

    2009-10-01

    To assess axis alignment and stability of the Toric Implantable Collamer Lens (TICL; STAAR Surgical Co) over time. Thirty-five consecutive eyes of 19 patients received the TICL for treatment of myopic astigmatism. Manifest refraction spherical equivalent (MRSE) and manifest refractive cylinder were measured preoperatively and at 3 months postoperatively. The axis alignment of the TICL was measured using the internal OPD map obtained with the OPD-Scan II (NIDEK Co Ltd). Mean refractive cylinder was reduced from 2.80+/-1.45 diopters (D) preoperatively to 0.63+/-0.75 D at 3 months postoperatively; MRSE was -7.61+/-4.02 D preoperatively and -0.14+/-0.38 D at 3 months. Mean absolute value of the measured axis misalignment from baseline (day 1) to 1 month was 2.90+/-2.11 degrees and from 1 month to 3 months was 4.6+/-11.2 degrees. Mean absolute value of the measured changes in axis misalignment from baseline to 3 months was 2.68+/-2.11 degrees (after excluding one eye that required repositioning due to TICL rotation). At 3 months postoperatively, 96.8% (30/31) eyes had axis misalignment. The TICL showed minimal axis misalignment after implantation and remained stable 3 months postoperatively. Copyright 2009, SLACK Incorporated.

  19. Clinical study of AcrySof IQ Toric intraocular lens implantation to corneal correct astigmatism

    Directory of Open Access Journals (Sweden)

    Qian Wang

    2014-09-01

    Full Text Available AIM: To observe the clinical outcome of implanting AcrySof IQ Toric intraocular lens to correct corneal astigmatism in cataract surgery, and to evaluate the result and rotational stability of AcrySof IQ Toric after cataract surgery. METHODS: A retrospective study of 26 eyes in 21 cataract patients with corneal astigmatism. All patients implanted AcrySof IQ Toric intraocular lens. The preoperative and postoperative uncorrected visual acuity(UCVA, best corrected visual acuity(BCVA, preoperative corneal astigmatism, anticipated residual astigmatism, total astigmatism, postoperative residual astigmatism and Toric lens axis were detected and measured.RESULTS: All patients' visual acuity and best corrected visual acuity improved significantly. The mean refractive cylinder decreased significantly after surgery from(2.05±0.57D to(0.55±0.33D(t=13.574, Pt=1.149, P>0.05. Three months after surgery, there was no significant difference between preoperative(2.01±0.58D and postoperative(-1.89±0.53D corneal astigmatism(t=1.908, P>0.05. The rotation of intraocular lens were CONCLUSION: The AcrySof IQ Toric lens make cataract patients enjoy the better UCVA including good rotational stability in the correct of corneal astigmatism. The AcrySof IQ Toric implantation is an effective option for the correct of preexisting corneal astigmatism in cataract surgery.

  20. Clinical observation of Artisan iris-clip intraocular lens implantation at stage Ⅰ

    Directory of Open Access Journals (Sweden)

    Qing Zhou

    2014-09-01

    Full Text Available AIM: To observe the clinical efficacy of Artisan iris-clip intraocular lens(IOLimplantation on cataract with a wide range of lens dislocation.METHODS: Twenty-four hospital patients(28 eyesof cataract with lens subluxation by trauma(20 patients, 20 eyesand Marfan's syndrome(4 patients, 8 eyesduring May 2007 to December 2011 were selected. All of them underwent phacoemulsification or an anterior vitrectomy and Artisan iris-clip IOL implantation at stage Ⅰ. Postoperative visual acuity, corneal endothelial cell count, intraocular lens position and postoperative complications were observed. Follow-up time was 6mo.RESULTS:Compared with the preoperative, postoperative best corrected visual acuity improved to varying degrees, visual acuity of 0.1-0.5 was in 20 eyes, 0.5-1.0 in 8 eyes. After followed up 1-6mo, no artificial lens shift, iris inflammation, iris atrophy and corneal decompensation and other complications were observed.CONCLUSION: Cataract surgery with a wide range of lens dislocation is difficult, but as long as surgeons who have a wealth of clinical experience and superb skills, still can carry out phacoemulsification surgery or anterior vitrectomy and Artisan iris-clip IOL implantation and obtain a better outcome.

  1. Clinical observation of capsular tension ring implantation in congenital lens subluxation treating by phacoemulsification

    Directory of Open Access Journals (Sweden)

    Liang-Nan Sun

    2017-07-01

    Full Text Available AIM: To evaluate the clinical results of capsular tension ring(CTRimplantation in phacoemulsification for eyes with congenital lens subluxation. METHODS: This study comprised 18 patients(31 eyeswith congenital ectopia lentis. All patients received phacoemulsification with CTR and intraocular lens(IOLimplantation. Visual acuity before and after surgery were examined. IOL decentration were measured with Image-Pro Plus image processing software. The complications were also recorded preoperatively and postoperatively. RESULTS: Uncorrected vision of all eyes increased after surgery, and all cases had different degree of IOL decentration after surgery. Two eyes received CTR scleral fixation 3mo after surgery because the IOL decentration aggravated during the follow-up period. CONCLUSION: Phacoemulsification with CTR and IOL implantation is effective and safe for congenital lens subluxation. The implantation of CTR increase the stability of the capsular bag, improve the safety of surgery, and maintain the right position of IOL. CTR scleral fixation is a effective supplement for progressive cases.

  2. Visual outcomes after lensectomy and iris claw artisan intraocular lens implantation in patients with Marfan syndrome.

    Science.gov (United States)

    Rabie, Hossein Mohammad; Malekifar, Parviz; Javadi, Mohammad Ali; Roshandel, Danial; Esfandiari, Hamed

    2017-08-01

    To review our experience with crystalline lens extraction and iris claw Artisan IOL implantation in patients with lens subluxation secondary to Marfan syndrome. A retrospective analysis of 12 eyes of 9 patients with lens subluxation due to Marfan syndrome who underwent crystalline lens removal and Artisan IOL (Ophtec, Groningen, Netherlands) implantation. A questionnaire of pre- and post-operative data, including demographics, pre- and postoperative comorbidities and complications was completed. Patients were evaluated for visual outcome and occurrence of complications. Uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), and spherical equivalents (SE) were compared before and after lens extraction and IOL insertion. The mean age of the participants was 30.03 ± 15.02 years, and mean post-operative follow-up time was 44.5 ± 16.4 months. Mean BCVA also showed a significant improvement from 0.5 ± 0.3 at the baseline to 0.2 ± 0.2 post-operatively (P = 0.006). SE changed significantly from -11.38 ± 1.99 preoperatively to -0.45 ± 1.65 post-operatively (P = 0.003). All eyes had the IOL implanted at desired position. Post-operative complications were retinal detachment in one case and IOL dislocation in another patient. No other complication such as ocular hypertension, angle abnormalities, clinical cystoids macular edema, and corneal decompensation was observed during the follow-up period. Artisan IOL implantation after lens extraction appears to be an attractive alternative for optical correction in cases of Marfan syndrome with ectopia lentis. It confers a significant improvement in visual acuity with reasonable risk profile.

  3. Intra-ocular lens implantation after vitreous loss.

    Directory of Open Access Journals (Sweden)

    Shah N

    1991-10-01

    Full Text Available Vitreous loss is a dreaded complication of cataract surgery, especially so with IOL implant which then may have to be abandoned. Thirty three cases of IOL implants, either anterior chamber or posterior chamber, after vitreous loss done in the past 3 years were studied. Of these, 18 (55% had a final visual acuity of 6/18 or better and none was worse than 6/60. The postoperative complications and findings and a review of literature are discussed.

  4. Long-term results of intraocular lens implantation in pediatric patients.

    Science.gov (United States)

    Sinskey, R M; Stoppel, J O; Amin, P

    1993-05-01

    Between 1980 and 1990, 42 eyes of 34 patients (age range: 18 months to 18 years) were implanted with an intraocular lens, with 29 being primary implantations and 13 secondary. The primary implantation group comprised patients with congenital, developmental, and traumatic cataracts. Patients in the developmental and traumatic cataract groups achieved the best visual acuity. Those with congenital cataracts had the poorest visual outcome. Follow-up ranged from a minimum of three months to more than ten years. Overall the patients demonstrated an improvement in visual acuity and the psychological advantage of enhanced visual function without spectacles or contact lenses. We conclude that with proper case selection and a controlled, skilled surgical approach, the use of an intraocular lens for visual rehabilitation in the pediatric age group is a feasible approach.

  5. Temporary Piggyback Intraocular Lens Implantation Versus Single Intraocular Lens Implantation in Congenital Cataracts: Long-Term Clinical Outcomes.

    Science.gov (United States)

    Hwang, Sungsoon; Lim, Dong Hui; Lee, Soomin; Choi, Daye Diana; Chung, Eui-Sang; Chung, Tae-Young

    2018-04-01

    To report the long-term results of temporary piggyback IOL implantation in congenital cataract and to compare the clinical outcomes of temporary piggyback IOL with those of single IOL implantation. This is a retrospective, comparative, interventional study. The medical records of all consecutive patients who underwent cataract extraction and single or temporary piggyback IOL implantation within the first 3 years of life from 1999 to 2013 at Samsung Medical Center were reviewed. Twenty-eight eyes from 18 patients underwent single IOL implantation (monopseudophakia group), and 32 eyes of 20 patients underwent temporary piggyback IOL implantation in congenital cataract surgery (polypseudophakia group). The mean age at initial cataract surgery was 15.8 months in the monopseudophakia group and 11.1 months in the polypseudophakia group (P = 0.144). The average follow-up duration was 133 months in the monopseudophakia group and 120 months in the polypseudophakia group (P = 0.391). The best-corrected visual acuity at the last visit was 0.36 logMAR in the monopseudophakia group and 0.55 logMAR in the polypseudophakia group (P = 0.044). Four (14%) and 14 (44%) reoperations for complications within the anterior segment were performed in the monopseudophakia group and polypseudophakia group, respectively (P = 0.042). Four cases (14.3%) in the monopseudophakia group and 13 cases (40.6%) in the polypseudophakia group had a glaucoma-related adverse event (P = 0.086). Compared with primary single IOL implantation in congenital cataract, temporary piggyback IOL implantation produced worse visual acuity, higher reoperation rate, and higher risk of secondary glaucoma. Temporary piggyback IOL implantation does not have benefit in congenital cataract.

  6. The balanced two-string technique for sulcus intraocular lens implantation in the absence of capsular support.

    Science.gov (United States)

    Ibrahim, Hesham A; Sabry, Heba Nabil

    2015-01-01

    Purpose. To describe and explore an alternative approach for sulcus intraocular lens (IOL) implantation in the absence of capsular support. Methods. The commonly available one-piece poly(methyl methacrylate) (PMMA) lens is stabilized in the sulcus by two intraocular horizontal strings of 10/0 polypropylene suture passed through the lens dialing holes in opposite directions to achieve a mechanical balance. The horizontal strings of 10/0 polypropylene work as a rail track for the IOL optics, allowing some side to side lens adjustment even following wound closure. The stability of the IOL was tested in vitro. Six aphakic patients underwent in-sulcus IOL secondary implantation using the balanced two-string technique. Patients were followed up for a minimum of six months. Best spectacle corrected vision was assessed. Lens centration and lens tilt were measured by anterior segment optical coherence tomography (AS-OCT). Results. All patients had successful lens insertion. Best spectacle corrected visual acuity (BSCVA) improved in all patients. Lens decentration ranged between 0.21 mm and 0.9 mm (average 0.53 mm). Lens tilt ranged between 1.2° and 2.8° (average 2.17°). Conclusion. The mechanically balanced two-string technique is an alternative option for sulcus IOL implantation in absence of capsular support, allowing lens centration adjustment with no additional risks.

  7. The Balanced Two-String Technique for Sulcus Intraocular Lens Implantation in the Absence of Capsular Support

    Science.gov (United States)

    Ibrahim, Hesham A.; Sabry, Heba Nabil

    2015-01-01

    Purpose. To describe and explore an alternative approach for sulcus intraocular lens (IOL) implantation in the absence of capsular support. Methods. The commonly available one-piece poly(methyl methacrylate) (PMMA) lens is stabilized in the sulcus by two intraocular horizontal strings of 10/0 polypropylene suture passed through the lens dialing holes in opposite directions to achieve a mechanical balance. The horizontal strings of 10/0 polypropylene work as a rail track for the IOL optics, allowing some side to side lens adjustment even following wound closure. The stability of the IOL was tested in vitro. Six aphakic patients underwent in-sulcus IOL secondary implantation using the balanced two-string technique. Patients were followed up for a minimum of six months. Best spectacle corrected vision was assessed. Lens centration and lens tilt were measured by anterior segment optical coherence tomography (AS-OCT). Results. All patients had successful lens insertion. Best spectacle corrected visual acuity (BSCVA) improved in all patients. Lens decentration ranged between 0.21 mm and 0.9 mm (average 0.53 mm). Lens tilt ranged between 1.2° and 2.8° (average 2.17°). Conclusion. The mechanically balanced two-string technique is an alternative option for sulcus IOL implantation in absence of capsular support, allowing lens centration adjustment with no additional risks. PMID:25722884

  8. The Balanced Two-String Technique for Sulcus Intraocular Lens Implantation in the Absence of Capsular Support

    Directory of Open Access Journals (Sweden)

    Hesham A. Ibrahim

    2015-01-01

    Full Text Available Purpose. To describe and explore an alternative approach for sulcus intraocular lens (IOL implantation in the absence of capsular support. Methods. The commonly available one-piece poly(methyl methacrylate (PMMA lens is stabilized in the sulcus by two intraocular horizontal strings of 10/0 polypropylene suture passed through the lens dialing holes in opposite directions to achieve a mechanical balance. The horizontal strings of 10/0 polypropylene work as a rail track for the IOL optics, allowing some side to side lens adjustment even following wound closure. The stability of the IOL was tested in vitro. Six aphakic patients underwent in-sulcus IOL secondary implantation using the balanced two-string technique. Patients were followed up for a minimum of six months. Best spectacle corrected vision was assessed. Lens centration and lens tilt were measured by anterior segment optical coherence tomography (AS-OCT. Results. All patients had successful lens insertion. Best spectacle corrected visual acuity (BSCVA improved in all patients. Lens decentration ranged between 0.21 mm and 0.9 mm (average 0.53 mm. Lens tilt ranged between 1.2° and 2.8° (average 2.17°. Conclusion. The mechanically balanced two-string technique is an alternative option for sulcus IOL implantation in absence of capsular support, allowing lens centration adjustment with no additional risks.

  9. Cataract Extraction With Intraocular Lens Implant: Early Experience ...

    African Journals Online (AJOL)

    -surgery was good (>/= 6/18.) confirming that Cataract surgery with IOL implant is safe and effective in restoring vision to the cataract blind in this part of the world. Most of the cases of postoperative astigmatism were corrected with refraction.

  10. Scleral fixation of one piece intraocular lens by injector implantation.

    Science.gov (United States)

    Can, Ertugrul; Basaran, Resat; Gul, Adem; Birinci, Hakki

    2014-08-01

    With an ab-interno technique of transscleral suturing of current one-piece posterior chamber intraocular lenses (PC IOLs) by injector implantation in the absence of capsular support, we aimed to demonstrate the possibility of the implantation of one-piece acrylic PC IOLs that might be produced in the future for only scleral fixation through small clear corneal incision. Case report and literature review. This procedure has been performed in eight aphakic eyes with four different types of IOLs. Good centration was achieved with minimal technical effort. All patients had well-centered and stable lenses postoperatively during 9-18 months follow-up. We managed to decrease the risks of surgical trauma and intricate surgical maneuvers requirement. With this technique, excessive fluid leakage and consecutive hypotony can be minimized.

  11. Pars plana vitrectomy with posterior iris claw implantation for posteriorly dislocated nucleus and intraocular lens

    Directory of Open Access Journals (Sweden)

    Kishor B Patil

    2011-01-01

    Full Text Available We evaluated the safety and efficacy of pars plana vitrectomy (PPV with primary posterior iris claw intraocular lens (IOL implantation in cases of posterior dislocation of nucleus and IOL without capsular support. This was a retrospective interventional case series. Fifteen eyes underwent PPV with primary posterior iris claw IOL implantation performed by a single vitreoretinal surgeon. The main outcome measures were changes in best corrected visual acuity and anterior and posterior segment complications. A total of 15 eyes were included in this study. Eight had nucleus drop, three had IOL drop during cataract surgery and four had traumatic posterior dislocation of lens. The final postoperative best corrected visual acuity was 20/60 or better in 11 patients. This procedure is a viable option in achieving good functional visual acuity in eyes without capsular support.

  12. Implantation of phakic intraocular lens in 3 patients with oculocutaneous albinism.

    Science.gov (United States)

    van Rijn, Gwyneth A; Snoek, Colette; Joosse, Maurits; Saxena, Ruchi; Luyten, Gregorius P M

    2013-10-01

    We present 3 cases with oculocutaneous albinism in which a high refractive error was optically corrected by implantation of an Artisan iris-fixated phakic intraocular lens, with a follow-up of 8 to 14 years. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  13. [The progress of studies on intraocular lens implantation in cataract with high myopia].

    Science.gov (United States)

    Liu, Xue; Wan, Xiuhua

    2015-07-01

    With development of the technology of cataract surgery, combined phacoemulsification and intraocular lens implantation in cataract with high myopia has been widely carried out in clinical treatment. Due to the particularity of high myopia, phacoemulsification in patients with cataract and high myopia is difficult and has recently received a lot of attentions. In this paper, preoperative examinations, the selection of intraocular lenses, surgery methods and surgical complications of cataract surgery in patients with cataract and high myopia are briefly reviewed.

  14. Comparison of intraocular pressure andvault after implantation of implantable collamer lens with and without a central hole.

    Science.gov (United States)

    Chen, Haiting; Niu, Guangzeng; Fan, Yuxiang; Ma, Jingxue

    2016-11-16

    The Implantable Collamer Lens (ICL) has been used widely for refractive errors, We performed this prospective randomized comparative study to compare postoperative intraocular pressure (IOP) and vaults of the eyes implanted with conventional ICL and central hole ICL. This study evaluated 44 eyes of 22 patients who underwent central hole ICL implantation in one eye and conventional ICL implantation in the other eye by randomization assignment. noncontact intraocular pressure were performed on 6 h, 1 day, 3 days, 1 week, 2 weeks, 1 month, 3 months and 6 months, while ICL vaults were measured on 1 day, 1 week, 1 month and 6 months. The IOP of both eyeswithcentral hole and conventional ICLrosetemporarily during the first month after surgeries, especially on 1 day and 2 weeks points postoperatively. The IOP ofeyes with central hole ICL was higher than that of conventionl ICL. The vaults ofeyes with central hole and conventional ICL decreased slightly with time but did not significantly affect the postoperative IOP. Despite the sensitivity of viscoelastic agents or inflammation, this newly developed central hole ICL implantation appears to be equivalent in safty and effcacy to conventional ICL implantation for the correction of ametropia. Current Controlled Trials ChiCTR-INR-16008896 . Retrospectively registered 24 July 2016.

  15. Early versus late traumatic cataract surgery and intraocular lens implantation.

    Science.gov (United States)

    Tabatabaei, S A; Rajabi, M B; Tabatabaei, S M; Soleimani, M; Rahimi, F; Yaseri, M

    2017-08-01

    PurposeTo determine the proper time for traumatic cataract surgery after open globe injuries.SettingFarabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran.DesignRandomized clinical trial.Patients and methodsIn a randomized clinical trial, 30 eyes with traumatic cataract after open globe injury with IOL implantation underwent early (in the first week after the trauma) and 30 eyes underwent late cataract surgery (from the first to second month after the trauma). We excluded patients who were under 12-year-old. All patients were visited at 1 week, 4 weeks, 12 weeks, and 6 months after surgery. In each visit, patients were examined regarding visual acuity, intraocular pressure (IOP), anterior chamber inflammation, IOL position, and posterior synechiae. In addition, posterior segment evaluation and fundoscopy were performed. Intraoperative complication including posterior capsular rupture, anterior vitrectomy, and zonulysis as well as the site of IOL implantation were documented and post-operative complications including raised IOP, anterior chamber inflammation, visual axis opacity, posterior synechiae, subluxation of IOL, and IOL pigment deposition were listed.ResultsBest-corrected visual acuity 6 months after surgery was not different between the two groups. Also in early cataract surgery group, the rate of posterior capsular rupture was not significantly higher than the late surgery group (P=0.069). On the other hand, zonulysis was significantly higher in the late procedure group (P=0.039). Other complications including anterior vitrectomy, raised IOP, anterior chamber inflammation, visual axis opacity, posterior synechiae, subluxation of IOL, and IOL pigment deposition were not different in the two groups.ConclusionsEarly and late traumatic cataract surgery and IOL implantation after open globe injuries, have no significant difference regarding the post-surgical BCVA and prominent intraoperative and post-operative complications.

  16. Posterior Vitreous Detachment and Retinal Detachment After Implantation of the Visian Phakic Implantable Collamer Lens

    OpenAIRE

    Bamashmus, Mahfouth A.; Al-Salahim, Seddique A.; Tarish, Nabil A.; Saleh, Mahmoud F.; Mahmoud, Hatem A.; Elanwar, Mohamed F.; Awadalla, Mohamed A.

    2013-01-01

    Introduction: To evaluate the vitreoretinal complications in myopes after Visian implantable collamer lenses (ICL) implantation. Materials and Methods: This is a retrospective, observational, non-comparative clinical study that evaluated 617 consecutive myopes who underwent ICL implantation at the Department of Refractive Surgery, Yemen Magrabi Hospital, Sana′a, Yemen between July 2006 and May 2010. Follow up ranged from 6 months to 40 months. Preoperative and postoperative patient evalua...

  17. Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique

    Directory of Open Access Journals (Sweden)

    M Isabel Canut Jordana

    2010-11-01

    Full Text Available M Isabel Canut Jordana1, Daniel Pérez Formigó1, Rodrigo Abreu González2, Jeroni Nadal Reus11Barraquer Ophthalmology Centre, Barcelona, Spain; 2University Hospital of La Candelaria, Tenerife, SpainAims: We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact.Methods: Complete ophthalmologic examination and optical coherence tomography (OCT of the anterior segment were performed.Results: Contact between the pigmentary epithelium and the iris with an intraocular lens was revealed by utrasound biomicroscopy and OCT. In this case, Nd:YAG laser iridotomy and laser iridoplasty were not effective for iridolenticular separation and control of the pigment dispersion. We propose a new technique: stitches on the surface of the iris to obtain good iridolenticular separation and good intraocular pressure control.Conclusion: Stitches on the iris surface should be considered as optional therapy in pigmentary glaucoma secondary to intraocular lens implantation. This surgical technique can avoid potential iridolenticular contacts more definitively.Keywords: pigmentary glaucoma, intraocular lens, optical coherence tomography, laser

  18. Retropupillary iris claw intraocular lens implantation in aphakia for dislocated intraocular lens.

    Science.gov (United States)

    Faria, Mun Yueh; Ferreira, Nuno Pinto; Pinto, Joana Medeiros; Sousa, David Cordeiro; Leal, Ines; Neto, Eliana; Marques-Neves, Carlos

    2016-01-01

    Nowadays, dislocated intraocular lenses (IOLs) and inadequate capsular support are becoming a challenge for every ophthalmic surgeon. Explantation of dislocated IOL and iris claw IOL (ICIOL) are the techniques that have been used in our ophthalmic department. The aim of this study is to report our technique for retropupillar ICIOL. This study is a retrospective case series. A total of 105 eyes with dislocated IOL from the patients at the Department of Ophthalmology in Santa Maria Hospital, a tertiary reference hospital in Lisbon, Portugal, from January 2012 until January 2016, had been analyzed. Of these 105 eyes, 66 eyes had dislocated one-piece IOL and 39 eyes had dislocated three-piece IOL. The latter underwent iris suture of the same IOL and were excluded from this study. The remaining 66 eyes with dislocated one-piece IOL underwent pars plana vitrectomy, that is, explantation of dislocated IOL through corneal incision and an implantation of retropupillary ICIOL. Operative data and postoperative outcomes included best corrected visual acuity, IOL position, intraocular pressure, pigment dispersion, clinical signs of endothelial cell loss, and anterior chamber depth. The mean follow-up was 23 months (range: 6-48 months). The mean preoperative best corrected visual acuity was 1.260±0.771 logMAR, and postoperative best corrected visual acuity was 0.352±0.400 logMAR units. Mean vision gain was 0.909 logMar units. The patients had the following complications: 1) retinal detachment was found in one patient, 2) corneal edema was found in three patients, 3) high intraocular pressure was observed in twelve patients, 4) subluxation of the IOL was observed in one patient, and 5) macular edema was found in three eyes. The results demonstrate that retropupillary ICIOL is an easy and effective method for the correction of aphakia in patients not receiving capsule support. The safety of this procedure must be interpreted in the context of a surgery usually indicated in

  19. Retropupillary iris claw intraocular lens implantation in aphakia for dislocated intraocular lens

    Directory of Open Access Journals (Sweden)

    Faria MY

    2016-08-01

    Full Text Available Mun Yueh Faria,1–3 Nuno Pinto Ferreira,1–3 Joana Medeiros Pinto,1–3 David Cordeiro Sousa,1–3 Ines Leal,1–3 Eliana Neto,1–3 Carlos Marques-Neves1–3 1Centro de Estudos da Visão, Universidade de Lisboa, 2Department of Ophthalmology, Hospital de Santa Maria, 3Faculty of Medicine, University of Lisbon, Lisbon, Portugal Background: Nowadays, dislocated intraocular lenses (IOLs and inadequate capsular support are becoming a challenge for every ophthalmic surgeon. Explantation of dislocated IOL and iris claw IOL (ICIOL are the techniques that have been used in our ophthalmic department. The aim of this study is to report our technique for retropupillar ICIOL.Methods: This study is a retrospective case series. A total of 105 eyes with dislocated IOL from the patients at the Department of Ophthalmology in Santa Maria Hospital, a tertiary reference hospital in Lisbon, Portugal, from January 2012 until January 2016, had been analyzed. Of these 105 eyes, 66 eyes had dislocated one-piece IOL and 39 eyes had dislocated three-piece IOL. The latter underwent iris suture of the same IOL and were excluded from this study. The remaining 66 eyes with dislocated one-piece IOL underwent pars plana vitrectomy, that is, explantation of dislocated IOL through corneal incision and an implantation of retropupillary ICIOL. Operative data and postoperative outcomes included best corrected visual acuity, IOL position, intraocular pressure, pigment dispersion, clinical signs of endothelial cell loss, and anterior chamber depth.Results: The mean follow-up was 23 months (range: 6–48 months. The mean preoperative best corrected visual acuity was 1.260±0.771 logMAR, and postoperative best corrected visual acuity was 0.352±0.400 logMAR units. Mean vision gain was 0.909 logMar units. The patients had the following complications: 1 retinal detachment was found in one patient, 2 corneal edema was found in three patients, 3 high intraocular pressure was observed in

  20. Carbachol as miotic agent in intra-ocular lens implant surgery

    Directory of Open Access Journals (Sweden)

    Agarwal Jitendra

    1988-01-01

    Full Text Available The intra cameral use of 0.025% carbachol as a miotic agent in anterior chamber intraocular lens im-plant surgery us reported in 15 cases. Carbachol produced prompt and effective moisis and was found to be harmless and non-irritating to the anterior chamber structures. A rebound dialatation of the pipit was noticed in the post operative period in 3 of our first 5 cases where only carbachol was used. For prolonged miosis instillation of a more powerful miotic like pilocarpine is recommended at the completion of surgery:

  1. Implantation of iris-claw Artisan intraocular lens for aphakia in Fuchs′ heterochromic iridocyclitis

    Directory of Open Access Journals (Sweden)

    Ahmad Kheirkhah

    2014-01-01

    Full Text Available Implantation of iris-claw Artisan intraocular lens (IOL is a surgical option for correction of aphakia; however, these IOLs have not been used in eyes with uveitis including Fuchs′ heterochromic iridocyclitis (FHI due to possible risk of severe postoperative intraocular inflammation. In the case reported here, we secondarily implanted an Artisan IOL in a 28-year-old man with FHI who had aphakia with no capsular support due to a previous complicated cataract surgery. Enclavation was easily performed and no intraoperative complication was noted. Postoperative course was uneventful with no significant anterior chamber inflammation during 12 months of follow-up. Although there were few deposits on the IOL surface, the patient achieved a best-corrected visual acuity of 20/20 without developing glaucoma or other complications. Therefore, Artisan IOL may be considered for correction of aphakia in patients with FHI. However, studies on large number of patients are required to evaluate safety of the procedure.

  2. Long-term refractive change after intraocular lens implantation in childhood.

    Science.gov (United States)

    Walker, Randy A; Romanchuk, Kenneth G

    2006-08-01

    To determine refractive change occurring with age in children who had cataract removal with intraocular lens implantation and in whom the immediate postoperative refraction was targeted either to match the refractive error of the opposite eye in unilateral cases, or for only a small refractive error when surgery was bilateral. Retrospective review of the refractive error over time in 36 eyes of 25 children who underwent cataract removal (11 bilateral) with insertion of an intraocular lens from 1987 to 1998 and who had at least 4 years follow-up, but no glaucoma. Mean age at surgery was 5.5 years (median 5.7 y, range 1.3-12 y), with a mean follow-up of 8 years (median 6 y, range 4-16 y). The average refraction followed a logarithmic decline with age. Although eyes with unilateral surgery had a slightly faster rate of change and lower final refraction than did eyes with bilateral surgery, this difference was not statistically significant. Variation from this trend was also observed in 3 patients. When the hyperopic refractive error created immediately after surgery was small, children usually became significantly myopic when older, often creating anisometropic myopia in unilateral cases. When implanting intraocular lenses bilaterally one should aim for a significant but balanced hyperopic correction immediately postoperatively in young patients, anticipating that there will be emmetropization with aging. Parents should be warned that variations can occur.

  3. Factors associated with strabismus after cataract extraction and primary intraocular lens implantation in congenital cataracts

    Directory of Open Access Journals (Sweden)

    Soo Jung Lee

    2014-06-01

    Full Text Available AIM: To evaluate factors associated with the development of strabismus after cataract extraction and primary intraocular lens implantation.METHODS: The medical records of 122 patients, aged 1.5mo to 9y, who had undergone cataract extraction with primary intraocular lens implantation between January 1993 and August 2011 were reviewed. Fourteen patients (17 eyes with strabismus before cataract surgery were excluded. Patients were divided into those with congenital bilateral cataracts (64 patients, 128 eyes and those with unilateral cataracts (44 patients, 44 eyes. The associations between the development of strabismus and age at cataract surgery, pre- and post-cataract extraction corrected distance visual acuity (CDVA, interocular CDVA difference, nystagmus, surgical method, and secondary cataract were evaluated.RESULTS: Factors significantly associated with the development of strabismus included age at cataract surgery (≤1y, preoperative mean CDVA ≤20/100, presence of nystagmus in the bilateral cataract group and postoperative interocular CDVA difference >20/70 in the unilateral group. Postoperative CDVA ≤20/100 and preservation of posterior capsule, and presence of secondary cataract were significant factors in both groups.CONCLUSION: Children with congenital cataracts should be monitored carefully after cataract surgery for the development of strabismus, especially when they underwent surgery at age ≤1y, and they have nystagmus, large postoperative interocular CDVA difference, poor preoperative and postoperative CDVA, preservation of the posterior capsule, or secondary cataract.

  4. Posterior vitreous detachment and retinal detachment after implantation of the Visian phakic implantable collamer lens.

    Science.gov (United States)

    Bamashmus, Mahfouth A; Al-Salahim, Seddique A; Tarish, Nabil A; Saleh, Mahmoud F; Mahmoud, Hatem A; Elanwar, Mohamed F; Awadalla, Mohamed A

    2013-01-01

    To evaluate the vitreoretinal complications in myopes after Visian implantable collamer lenses (ICL) implantation. This is a retrospective, observational, non-comparative clinical study that evaluated 617 consecutive myopes who underwent ICL implantation at the Department of Refractive Surgery, Yemen Magrabi Hospital, Sana'a, Yemen between July 2006 and May 2010. Follow up ranged from 6 months to 40 months. Preoperative and postoperative patient evaluation included manifest and cycloplegic refractions, uncorrected (UCVA) and best spectacle-corrected visual acuity (BSCVA), slit-lamp biomicroscopy, intraocular pressure and dilated retinal examination. Investigations included corneal topography, central corneal thickness, anterior chamber depth and white to white diameter. Retinal diseases and complications were recorded and analyzed preoperatively and postoperatively. Preoperatively, 61 (9.9%) eyes had posterior segment pathology requiring prophylactic laser photocoagulation. One eye developed spontaneous rhegmatogenous retinal detachment (RRD), one eye developed traumatic retinal detachment and two eyes required laser treatment postoperatively. The overall retinal detachment rate post-ICL was 0.32%. Posterior segment complications are rare after ICL implantation but dilated vitreoretinal assessment is important before and after the procedure. Patients with suspicious retinal lesions need a comprehensive vitreoretinal evaluation by a retinal specialist. If a patient develops floaters or blurry vision he/she requires further assessment by a vitreoretinal specialist.

  5. Comparison between bilateral implantation of a trifocal intraocular lens and blended implantation of two bifocal intraocular lenses

    Directory of Open Access Journals (Sweden)

    Vilar C

    2017-08-01

    Full Text Available César Vilar,1,2 Wilson Takashi Hida,1–3 André Lins de Medeiros,1,2 Klayny Rafaella Pereira Magalhães,2 Patrick Frensel de Moraes Tzelikis,1,2 Mario Augusto Pereira Dias Chaves,2,4 Antônio Francisco Pimenta Motta,2,3 Pedro Carlos Carricondo,1–3 Milton Ruiz Alves,3 Walton Nosé5 1Cataract Division, Brasília Ophthalmologic Hospital (HOB, Brasília-DF, Brazil; 2Renato Ambrosio Ophthalmologic Research Center (CEORA, 3Ophthalmology Department, São Paulo University – USP, São Paulo-SP, Brazil; 4Cataract Division, ProVisão, João Pessoa-PB, Brazil; 5Ophthalmology Department, Paulista Medical School – UNIFESP, São Paulo-SP, Brazil Purpose: To compare visual outcomes and performance between bilateral implantation of a diffractive trifocal intraocular lens (IOL Acrysof®PanOptix® TFNT00 and blended implantation of two different near add power bifocal IOLs: Acrysof® Restor® SV25T0 in dominant eye and Acrysof® Restor® SN6AD1 in the nondominant eye.Methods: This prospective, nonrandomized, consecutive and comparative study assessed 20 patients (40 eyes who had bilateral cataract surgery performed using the IOLs described. Patients were divided into groups, bilateral trifocal implant and blended implant. Evaluation included measurement of binocular uncorrected and corrected distance visual acuity at 4 m (UDVA, CDVA and uncorrected intermediate (60 cm and near (at 40 cm visual acuity; contrast sensitivity (CS and visual defocus curve.Results: Postoperative CDVA comparison showed no statistical significance between groups. UDVA was significantly better in the trifocal groups. Under photopic conditions, the trifocal group had better CS in higher frequencies with and without glare. The binocular defocus curve demonstrated a trifocal behavior in both groups, with the bilateral trifocal group exhibiting better performance for intermediate vision.Conclusion: Both lens combinations were able to provide good near, intermediate and distance vision

  6. Influence of corneal asphericity on the refractive outcome of intraocular lens implantation in cataract surgery.

    Science.gov (United States)

    Savini, Giacomo; Hoffer, Kenneth J; Barboni, Piero

    2015-04-01

    To evaluate the possible influence of anterior corneal surface asphericity on the refractive outcomes in eyes having intraocular lens (IOL) implantation after cataract surgery. Fondazione G.B. Bietti IRCCS, Rome, Italy. Retrospective comparative case series. Intraocular lens power was calculated using the Haigis, Hoffer Q, Holladay 1, and SRK/T formulas. Asphericity (Q-value) was measured at 8.0 mm with a Placido-disk corneal topographer (Keratron), a rotating Scheimpflug camera (Pentacam), and a rotating Scheimpflug camera combined with Placido-disk corneal topography (Sirius). The relationship between the error in refraction prediction (ie, difference between expected refraction and refraction measured 1 month after surgery) and the Q-value was assessed by linear regression. The same IOL model (Acrysof SA60AT) was implanted in 115 eyes of 115 consecutive patients. Regression analysis showed a statistically significant relationship between the error in refraction prediction and the Q-value with all formulas and all devices. In all cases, a more negative Q-value (prolate cornea) was associated with a myopic outcome, whereas a more positive Q-value (oblate cornea) was associated with a hyperopic outcome. The highest coefficient of determination was detected between the Hoffer Q formula and the Placido-disk corneal topographer (R(2) = 0.2630), for which the error in refraction prediction (y) was related to the Q-value (x) according to the formula y = -0.2641 + 1.4589 × x. Corneal asphericity influences the refractive outcomes of IOL implantation and should be taken into consideration when using third-generation IOL power formulas. Dr. Hoffer receives book royalties from Slack, Inc., Thorofare, New Jersey, and formula royalties from all manufacturers using the Hoffer Q formula. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. Results of intraocular lens implantation with capsular tension ring in subluxated crystalline or cataractous lenses in children

    OpenAIRE

    Das, Pranab; Ram, Jagat; Brar, Gagandeep Singh; Dogra, Mangat R

    2009-01-01

    Purpose : To evaluate the outcome of intraocular lens (IOL) implantation using capsular tension ring (CTR) in subluxated crystalline or cataractous lenses in children. Setting : Tertiary care setting Materials and Methods : We prospectively studied 18 eyes of 15 children with subluxation of crystalline or cataractous lenses between 90° up to 210° after phacoemulsification, CTR and IOL implantation. Each child was examined for IOL centration, zonular dehiscence and posterior ...

  8. Toric Intraocular Lens Implantation for Correction of Astigmatism in Cataract Patients with Corneal Ectasia

    Directory of Open Access Journals (Sweden)

    Efstratios A. Parikakis

    2013-11-01

    Full Text Available Our purpose was to examine the long-term efficacy of toric intraocular lens (IOL implantation in cataract patients with high astigmatism due to corneal ectasia, who underwent phacoemulsification cataract surgery. Five eyes of 3 cataract patients with topographically stable keratoconus or pellucid macular degeneration (PMD, in which phacoemulsification with toric IOL implantation was used to correct high astigmatism, are reported. Objective and subjective refraction, visual acuity measurement and corneal topography were performed in all cases before and after cataract surgery. In all cases, there was a significant improvement in visual acuity, as well as refraction, which remained stable over time. Specifically, in subjective refraction, all patients achieved visual acuity from 7/10 to 9/10 with up to -2.50 cyl. Corneal topography also remained stable. Postoperative follow-up was 18-28 months. Cataract surgery with toric IOL implantation seems to be safe and effective in correcting astigmatism and improving visual function in cataract patients with topographically stable keratoconus or PMD.

  9. Correction of High Astigmatism after Penetrating Keratoplasty with Toric Multifocal Intraocular Lens Implantation

    Directory of Open Access Journals (Sweden)

    Raffaele Nuzzi

    2017-07-01

    Full Text Available After penetrating keratoplasty (PK, high astigmatism is often induced, being frequently about 4–6 dpt. According to the entity and typology of astigmatism, different methods of correction can be used. Selective suture removal, relaxing incisions, wedge resections, compression sutures, photorefractive keratectomy, and laser-assisted in situ keratomileusis can reduce corneal astigmatism and ametropia, but meanwhile they can cause a reduction in the corneal integrity and cause an over- or undercorrection. In case of moderate-to-high regular astigmatisms, the authors propose a toric multifocal intraocular lens (IOL implantation to preserve the corneal integrity (especially in PK after herpetic corneal leukoma keratitis. We evaluated a 45-year-old patient who at the age of 30 was subjected to PK in his left eye due to corneal leukoma herpetic keratitis, which led to high astigmatism (7.50 dpt cyl. 5°. The patient was subjected to phacoemulsification and customized toric multifocal IOL implantation in his left eye. The correction of PK-induced residual astigmatism with a toric IOL implantation is an excellent choice but has to be evaluated in relation to patient age, corneal integrity, longevity graft, and surgical risk. It seems to be a well-tolerated therapeutic choice and with good results.

  10. Clinical Outcomes after Binocular Implantation of a New Trifocal Diffractive Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Florian T. A. Kretz

    2015-01-01

    Full Text Available Purpose. To evaluate visual, refractive, and contrast sensitivity outcomes, as well as the incidence of pseudophakic photic phenomena and patient satisfaction after bilateral diffractive trifocal intraocular lens (IOL implantation. Methods. This prospective nonrandomized study included consecutive patients undergoing cataract surgery with bilateral implantation of a diffractive trifocal IOL (AT LISA tri 839MP, Carl Zeiss Meditec. Distance, intermediate, and near visual outcomes were evaluated as well as the defocus curve and the refractive outcomes 3 months after surgery. Photopic and mesopic contrast sensitivity, patient satisfaction, and halo perception were also evaluated. Results. Seventy-six eyes of 38 patients were included; 90% of eyes showed a spherical equivalent within ±0.50 diopters 3 months after surgery. All patients had a binocular uncorrected distance visual acuity of 0.00 LogMAR or better and a binocular uncorrected intermediate visual acuity of 0.10 LogMAR or better, 3 months after surgery. Furthermore, 85% of patients achieved a binocular uncorrected near visual acuity of 0.10 LogMAR or better. Conclusions. Trifocal diffractive IOL implantation seems to provide an effective restoration of visual function for far, intermediate, and near distances, providing high levels of visual quality and patient satisfaction.

  11. [Lens exchange for subluxation of posterior chamber lenses implanted in the capsular bag or in the ciliary sulcus].

    Science.gov (United States)

    Stürmer, J

    2013-04-01

    There are an increasing number of patients with decreased vision due to dislocated posterior chamber lenses, with pseudoexfoliation being the main risk factor. Various techniques for refixation of the subluxated posterior chamber IOL have been described. Experience with our technique of IOL-explantation, anterior vitrectomy and implantation of an Artisan anterior chamber lens are presented. In a retrospective study design all lens exchanges with implantation of an Artisan anterior chamber lens performed between 2003 and 2012 are analyzed. The study included 65 eyes of 61 patients (age 79.6 ± 9.2 years: 43-98). The majority of eyes (46/65; 70.8%) had Sundown Syndrome (late in-the-bag intraocular lens dislocation), in 19 eyes the posterior chamber lens was implanted primary or secondary into the ciliary sulcus. In the 46 eyes with Sundown Syndrome cataract surgery with implantation of a posterior chamber lens in the capsular bag was performed 7.4 ± 3.7 (1-22) years before subluxation within the bag. Pseudoexfoliation was the main risk factor in 42/46 (91.2%) of these eyes. A capsular tension ring (CTR) was implanted during cataract surgery in 34/46 (73.9%) eyes. The 34 IOLs with a CTR luxated significantly earlier (p IOLs without a CTR (6.6 ± 3.6 years; median 5.8 vs. 9.4 ± 3.1 years; median 9.2). The average visual gain was 0.2 logMAR in the group of luxated capsular bag lenses and 0.12 logMAR in the group of luxated sulcus lenses. Postoperative IOP decompensation was seen in 17/65 (26.2%) eyes (requiring IOP-lowering surgery in 8 eyes), 7 eyes developed corneal decompensation, 5 eyes had central retinal vein occlusion and one eye developed postoperative endophthalmitis. Lens exchange with implantation of an Artisan anterior chamber lens has become a routine procedure to improve vision in patients with subluxated IOLs. Postoperative IOP decompensation and vascular problems are the major complications. Georg Thieme Verlag KG Stuttgart · New York.

  12. Comparison of optical quality after implantable collamer lens implantation and wavefront-guided laser in situ keratomileusis

    Directory of Open Access Journals (Sweden)

    Hong-Ting Liu

    2018-04-01

    Full Text Available AIM: To compare the optical quality after implantation of implantable collamer lens (ICL and wavefront-guided laser in situ keratomileusis (WG-LASIK. METHODS: The study included 40 eyes of 22 patients with myopia who accepted ICL implantation and 40 eyes of 20 patients with myopia who received WG-LASIK. Before surgery and three months after surgery, the objective scattering index (OSI, the values of modulation transfer function (MTF cutoff frequency, Strehl ratio, and the Optical Quality Analysis System (OQAS values (OVs were accessed. The higher order aberrations (HOAs data including coma, trefoil, spherical, 2nd astigmatism and tetrafoil were also obtained. For patients with pupil size <6 mm, HOAs data were analyzed for 4 mm-pupil diameter. For patients with pupil size ≥6 mm, HOAs data were calculated for 6 mm-pupil diameter. Visual acuity, refraction, pupil size and intraocular pressures were also recorded. RESULTS: In both ICL and WG-LASIK group, significant improvements in visual acuities were found postoperatively, with a significant reduction in spherical equivalent (P< 0.001. After the ICL implantation, the OSI decreased slightly from 2.34±1.92 to 2.24±1.18 with no statistical significance (P=0.62. While in WG-LASIK group, the OSI significantly increased from 0.68±0.43 preoperatively to 0.91±0.53 postoperatively (Wilcoxon signed ranks test, P=0.000. None of the mean MTF cutoff frequency, Strehl ratio, OVs showed statistically significant changes in both ICL and WG-LASIK groups. In the ICL group, there were no statistical differences in the total HOAs for either 4 mm-pupil or 6 mm-pupil. In the WG-LASIK group, the HOA parameters increased significantly at 4 mm-pupil. The total ocular HOAs, coma, spherical and 2nd astigmatism were 0.12±0.06, 0.06±0.03, 0.00±0.03, 0.02±0.01, respectively. After the operation, these values were increased into 0.16±0.07, 0.08±0.05, -0.04±0.04, 0.03±0.01 respectively (Wilcoxon signed ranks test

  13. Effect of supplementary implantation of a sulcus-fixated intraocular lens in patients with negative dysphotopsia.

    Science.gov (United States)

    Makhotkina, Natalia Y; Dugrain, Vincent; Purchase, Daniel; Berendschot, Tos T J M; Nuijts, Rudy M M A

    2018-02-01

    To evaluate whether the outcome of negative dysphotopsia treatment by implantation of a Sulcoflex intraocular lens (IOL) can be understood using individual biometry and optical modeling data. University Eye Clinic, Maastricht University Medical Centre, Maastricht, the Netherlands. Retrospective case series. Patients with negative dysphotopsia were treated with supplementary implantation of a sulcus-fixated IOL. Preoperative and postoperative ray-tracing optical models of eyes with negative dysphotopsia were constructed in the Zemax Optic Studio program using individual biometric data. The relationship between biometric parameters, ray-tracing data, and the course of negative dysphotopsia was evaluated. The study comprised 8 patients (10 eyes). After surgery, negative dysphotopsia resolved completely in 6 eyes, partially in 2 eyes, and persisted in 2 eyes. There was no relationship between the course of negative dysphotopsia and age, IOL power, or individual biometry results other than a larger angle κ that was observed in 2 patients with persistent negative dysphotopsia after surgery. Preoperative ray-tracing models showed a decrease in light irradiance at the periphery relative to the center of visual field. After sulcus-fixated IOL implantation, this decrease partially resolved, in particular, for a small pupil aperture (P < .05), and it was more prominent in patients in whom negative dysphotopsia resolved completely than in those with partial or persistent negative dysphotopsia (P = .065 at 1.5 mm aperture). Of all individual biometry results, only angle κ showed a relationship with the course of negative dysphotopsia. In patient-specific optical modeling of sulcus-fixated IOL implantation, the increase in simulated light irradiance at the periphery was related to the course of negative dysphotopsia. Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. [Evaluation of visual performance after implantation of a double C-Loop toric intraocular lens].

    Science.gov (United States)

    Chassain, C

    2014-09-01

    This study aims to demonstrate the safety and the efficacy of the Ankoris posterior chamber intraocular lens to correct corneal astigmatism at the time of cataract surgery. In this retrospective study, 52 eyes among the first 64 consecutive ones implanted with the Ankoris met the inclusion criteria. The retrospective analysis of these cases consisted mainly of the determination of the improvement in visual acuity and postoperative refraction. The analysis of the astigmatism correction itself was carried out by the Alpins method. The rotational stability of the implant was analyzed by the difference between the IOL orientation after one day and 3 months. The safety index, defined as the postoperative divided by preoperative best visual acuity, was greater than one in all cases, with a mean of 1.96. The ratio of the postoperative uncorrected visual acuity with the preoperative best-corrected acuity was 1.72. The final postoperative astigmatism was -0.40 ± 0.28 D. The percentage of astigmatism corrected was 99.3%. The error vector amplitude was 0.1 D with a nearly null orientation. The mean rotation was 2.16 ± 1.95°. The Ankoris IOL demonstrates, in this relatively large cohort, all necessary elements to establish that the IOL was able to correct corneal astigmatism at the same time as cataract surgery. Copyright © 2014. Published by Elsevier Masson SAS.

  15. Posterior chamber lens implantation with scleral fixation in children with traumatic cataract.

    Science.gov (United States)

    Caca, Ihsan; Sahin, Alparslan; Ari, Seyhmus; Alakus, Fuat

    2011-01-01

    To evaluate the outcomes of posterior chamber lens implantation with scleral fixation (SF-PCIOL) in children with traumatic cataract. Twenty-four eyes of 24 cases were included. All patients had corneal or corneoscleral lacerations that were primarily repaired. Traumatic cataract subsequently developed and SF-PCIOL was performed due to insufficient posterior capsule support. The average age of the patients was 5.8 years (range: 4 to 10 years). All cases had SF-PCIOL implanted via internal route using triangular double scleral flaps made of 9-0 polypropylene after a complete anterior vitrectomy. Average follow-up was 14.6 ± 4.3 months (range: 11 to 18 months). Visual acuity was increased at the last visit in 23 (96%) patients. Common postoperative complications were fibrinous reaction in 6 (25%) patients, transient intraocular pressure increase in 4 (17%) patients, membrane formation requiring removal in 1 (4%) patient, transient intraocular hemorrhage as vitreous hemorrhage in 1 (4%) patient, and retinal detachment in 1 (4%) patient after the postoperative second month. SF-PCIOL is an effective and reliable method in patients with pediatric traumatic cataract who had insufficient posterior capsule support. Copyright 2011, SLACK Incorporated.

  16. Clinical Outcomes after Uncomplicated Cataract Surgery with Implantation of the Tecnis Toric Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Wojciech Lubiński

    2016-01-01

    Full Text Available Purpose. To evaluate the clinical outcomes after uncomplicated cataract surgery with implantation of an aspheric toric intraocular lens (IOL during a 6-month follow-up. Methods. Prospective study including 27 consecutive eyes of 18 patients (mean age: 66.1±11.4 years with a visually significant cataract and corneal astigmatism ≥ 0.75 D and undergoing uncomplicated cataract surgery with implantation of the Tecnis ZCT toric IOL (Abbott Medical Optics. Visual, refractive, and keratometric outcomes as well as IOL rotation were evaluated during a 6-month follow-up. At the end of the follow-up, patient satisfaction and perception of optical/visual disturbances were also evaluated using a subjective questionnaire. Results. At 6 months after surgery, mean LogMAR uncorrected (UDVA and corrected distance visual acuity (CDVA were 0.19±0.12 and 0.14±0.10, respectively. Postoperative UDVA of 20/40 or better was achieved in 92.6% of eyes. Mean refractive cylinder decreased significantly from −3.73±1.96 to −1.42±0.88 D (p<0.001, while keratometric cylinder did not change significantly (p=0.44. Mean absolute IOL rotation was 1.1±2.4°, with values of more than 5° in only 2 eyes (6.9%. Mean patient satisfaction score was 9.70±0.46, using a scale from 0 (not at all satisfied to 10 (very satisfied. No postoperative optical/visual disturbances were reported. Conclusion. Cataract surgery with implantation of the Tecnis toric IOL is an effective method of refractive correction in eyes with corneal astigmatism due to the good IOL positional stability, providing high levels of patient’s satisfaction.

  17. Results of intraocular lens implantation with capsular tension ring in subluxated crystalline or cataractous lenses in children.

    Science.gov (United States)

    Das, Pranab; Ram, Jagat; Brar, Gagandeep Singh; Dogra, Mangat R

    2009-01-01

    To evaluate the outcome of intraocular lens (IOL) implantation using capsular tension ring (CTR) in subluxated crystalline or cataractous lenses in children. Tertiary care setting. We prospectively studied 18 eyes of 15 children with subluxation of crystalline or cataractous lenses between 90 degrees up to 210 degrees after phacoemulsification, CTR and IOL implantation. Each child was examined for IOL centration, zonular dehiscence and posterior capsular opacification (PCO). Age of the patient ranged between five to 15 years. Out of 18 eyes, seven had traumatic and 11 had spontaneous subluxation of crystalline or cataractous lens. Phacoemulsification was successfully performed with CTR implantation in the capsular bag. Intraoperative zonular dialysis occurred in two eyes. Anterior vitrectomy was performed in six eyes to manage vitreous prolapse. IOL implanted was polymethyl methacrylate (PMMA) in eight eyes, hydrophobic acrylic in seven and hydrophilic acrylic in three. Follow-up ranged from 24 months to 72 months. Sixteen eyes had a best corrected visual acuity of 20/40 or better. Nine eyes developed significant PCO and were managed with Neodymium Yttrium Aluminum Garnet (Nd:YAG) laser posterior capsulotomy. One eye with acrylic IOL in the capsular bag had IOL dislocation after two years which was managed with vitrectomy and secondary trans-scleral fixation of IOL. Phacoaspiration with CTR implantation makes capsular bag IOL fixation possible in most of the eyes with subluxated crystalline or cataractous lenses. PCO still remains a challenge in children with successful phacoaspiration with CTR implantation.

  18. Results of intraocular lens implantation with capsular tension ring in subluxated crystalline or cataractous lenses in children

    Directory of Open Access Journals (Sweden)

    Das Pranab

    2009-01-01

    Full Text Available Purpose : To evaluate the outcome of intraocular lens (IOL implantation using capsular tension ring (CTR in subluxated crystalline or cataractous lenses in children. Setting : Tertiary care setting Materials and Methods : We prospectively studied 18 eyes of 15 children with subluxation of crystalline or cataractous lenses between 90° up to 210° after phacoemulsification, CTR and IOL implantation. Each child was examined for IOL centration, zonular dehiscence and posterior capsular opacification (PCO. Results : Age of the patient ranged between five to 15 years. Out of 18 eyes, seven had traumatic and 11 had spontaneous subluxation of crystalline or cataractous lens. Phacoemulsification was successfully performed with CTR implantation in the capsular bag. Intraoperative zonular dialysis occurred in two eyes. Anterior vitrectomy was performed in six eyes to manage vitreous prolapse. IOL implanted was polymethyl methacrylate (PMMA in eight eyes, hydrophobic acrylic in seven and hydrophilic acrylic in three. Follow-up ranged from 24 months to 72 months. Sixteen eyes had a best corrected visual acuity of 20/40 or better. Nine eyes developed significant PCO and were managed with Neodymium Yttrium Aluminum Garnet (Nd:YAG laser posterior capsulotomy. One eye with acrylic IOL in the capsular bag had IOL dislocation after two years which was managed with vitrectomy and secondary trans-scleral fixation of IOL. Conclusions : Phacoaspiration with CTR implantation makes capsular bag IOL fixation possible in most of the eyes with subluxated crystalline or cataractous lenses. PCO still remains a challenge in children with successful phacoaspiration with CTR implantation

  19. Phacoemulsification with primary implantation of an intraocular lens in patients with uveitis

    Directory of Open Access Journals (Sweden)

    Pålsson S

    2017-08-01

    Full Text Available Sara Pålsson,1,2 Marita Andersson Grönlund,1,2 Dragana Skiljic,1,2 Madeleine Zetterberg1,2 1Department of Clinical Neuroscience/Ophthalmology, Institute of Neuroscience and Physiology, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; 2Department of Ophthalmology, Sahlgrenska University Hospital, Mölndal, Sweden Purpose: To evaluate the outcome of cataract surgery in adult patients with uveitis. Materials and methods: In this retrospective cohort study, medical charts of patients with uveitis and matched control patients without uveitis who underwent cataract surgery at the Eye Clinic, Sahlgrenska University Hospital, Mölndal, between January 2005 and December 2009 were analyzed. Results: The study included 58 eyes with and 283 eyes without uveitis. The most common etiologies were idiopathic anterior uveitis and Fuchs’ heterochromic uveitis. Postoperative visual acuity at 4 weeks was ≥0.5 decimal (0.3 logMAR in 48 eyes with uveitis (87.3% compared to 180 non-uveitic eyes (86.1%. Four eyes with uveitis (7.1% and one eye without uveitis (0.5% developed postoperative intraocular hypertension/glaucoma. Posterior capsule opacification developed in 11 eyes (19.0% with and 28 eyes (12.4% without uveitis. Conclusion: With appropriate perioperative anti-inflammatory regimen and surveillance, modern cataract surgery using phacoemulsification and primary intraocular lens implantation can be performed in patients with uveitis without greater risk of complications, yielding similar visual outcome as in patients without uveitis. Keywords: cataract, intraocular lens, phacoemulsification, uveitis

  20. Modern Phacoemulsification and Intraocular Lens Implantation (Refractive Lens Exchange) Is Safe and Effective in Treating High Myopia.

    Science.gov (United States)

    Srinivasan, Bhaskar; Leung, Hiu Ying; Cao, He; Liu, Shu; Chen, Lizhen; Fan, Alex Hoi

    Improved efficacy, predictability, and safety of modern phacoemulsification have resulted in cataract surgery being considered as a refractive procedure. Refractive lens exchange by definition is a surgery aimed at replacing the cataractous or clear crystalline lens with an intraocular lens (IOL) in cases of high ametropia. The excellent intraocular optics of this procedure provide a better visual outcome as compared with laser refractive surgery in high myopia. With advances in technology and IOL formulas, the predictability of refractive outcome after cataract surgery in high myopes has improved. The option of addressing presbyopia using multifocal/accommodating IOLs or monovision results in patients achieving reasonable spectacle independence. The most important concern with respect to phacoemulsification in high myopia is the risk of pseudophakic retinal detachment. High myopia is an independent risk factor for retinal detachment, and recent publications have reported a much lesser risk of retinal detachment specifically attributable to phacoemulsification in high myopes, especially if a thorough posterior segment evaluation is done and patients are followed up until development of complete posterior vitreous detachment. Refractive lens exchange is an effective and safe option to correct high myopia and can significantly improve quality of life in select patients.

  1. Multiple methods of surgical treatment combined with primary IOL implantation on traumatic lens subluxation/dislocation in patients with secondary glaucoma

    OpenAIRE

    Wang, Rui; Bi, Chun-Chao; Lei, Chun-Ling; Sun, Wen-Tao; Wang, Shan-Shan; Dong, Xiao-Juan

    2014-01-01

    AIM:To describe clinical findings and complications from cases of traumatic lens subluxation/dislocation in patients with secondary glaucoma, and discuss the multiple treating methods of operation combined with primary intraocular lens (IOL) implantation.METHODS:Non-comparative retrospective observational case series. Participants:30 cases (30 eyes) of lens subluxation/dislocation in patients with secondary glaucoma were investigated which accepted the surgical treatment by author in the Opht...

  2. Small-aperture corneal inlay in presbyopic patients with prior phakic intraocular lens implantation surgery: 3-month results

    Directory of Open Access Journals (Sweden)

    Huseynova T

    2013-08-01

    Full Text Available Tukezban Huseynova,1 Tomomi Kanamori,1 George O Waring IV,2 Minoru Tomita1,3,4 1Shinagawa LASIK Center, Tokyo, Japan; 2Medical University of South Carolina, Charleston, SC, USA; 3Wenzhou Medical College, Wenzhou, People’s Republic of China; 4Eye Can Cataract Surgery Center, Metro Manila, Philippines Abstract: We report a series of three case reports of KAMRA inlay implantation procedures in presbyopic patients with a history of prior phakic intraocular lens implantation surgery. Three-month results showed a two to five-line improvement for uncorrected near visual acuity. The absolute uncorrected near visual acuity change for case 1 was from J4 to J2, for case 2 was from J6 to J4, and for case 3 was from J10 to J5. No significant change of uncorrected distance visual acuity was observed in all three cases. Keywords: phakic intraocular lens, IOL, KAMRA, intracorneal inlay

  3. Eight-year follow-up of posterior chamber phakic intraocular lens implantation for moderate to high myopia.

    Science.gov (United States)

    Igarashi, Akihito; Shimizu, Kimiya; Kamiya, Kazutaka

    2014-03-01

    To assess the long-term clinical outcomes of Implantable Collamer Lens (Visian ICL; STAAR Surgical) implantation for moderate to high myopia. Retrospective observational case series. This study evaluated 41 eyes of 41 patients with myopic refractive errors of -4.00 to -15.25 diopters (D) who underwent ICL implantation and routine postoperative examinations. Before surgery, and 1 and 6 months and 1, 4 and 8 years after surgery, we assessed the safety, efficacy, predictability, stability, and adverse events of the surgery. The safety and efficacy indices were 1.13 ± 0.27 and 0.83 ± 0.36. At 8 years, 68.3% and 85.4% of the eyes were within 0.5 and 1.0 D, respectively, of the targeted correction. Manifest refraction changes of -0.32 ± 0.73 D occurred between 1 month and 8 years. The mean endothelial cell loss from preoperative levels was 6.2% at 8 years. Two eyes (4.9%) developed clinically significant symptomatic cataract during the follow-up period. Simultaneous lens extraction and phacoemulsification with IOL implantation was successfully performed in these 2 eyes. According to our experience, ICL implantation was overall good in measures of safety, efficacy, predictability, and stability for the correction of moderate to high myopia during the 8-year observation period, suggesting its long-term viability as a surgical option for the treatment of such eyes. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Visual outcomes after implantation of a novel refractive toric multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Talita Shimoda

    2014-04-01

    Full Text Available Purpose: To assess the postoperative outcomes of a novel toric multifocal in traocular lens (IOL in patients with cataract and corneal astigmatism. Methods: This prospective nonrandomized study included patients with cataract, corneal astigmatism, and a motivation for spectacle independence. In all patients, a Rayner M-flex® T toric IOL was implanted in the capsular bag. Three months after surgery, the distance, intermediate, and near visual acuities; spherical equivalent; residual refractive astigmatism; defocus curve; and contrast sensitivity were evaluated. A patient satisfaction and visual phenomena questionnaire was administered to all patients. Results: Thirty-four eyes of 18 patients were included in this study. Three months after surgery, the mean corrected distance visual acuity (logMAR was 0.00 ± 0.08 at 6 m, 0.20 ± 0.09 at 70 cm, and 0.08 ± 0.11 at 40 cm. Uncorrected distance vision acuity was 20/40 or better in 100% eyes. The preoperative mean refractive cylinder (RC was -2.19 (SD: ± 0.53. After a 3-month follow-up, the average RC was -0.44 D (SD: ± 0.27; p<0.001. Contrast sensitivity levels were high. At the last follow-up, 87.5% patients were spectacle-independent for near, intermediate, and distance vision, and approximately 44% patients reported halos and glare. Conclusion: Toric multifocal IOL implantation in patients with cataract and corneal astigmatism using the Rayner M-flex® T toric IOL was a simple, safe, and accurate option. This technology provides surgeons with a feasible option for meeting patient expectations of an enhanced lifestyle resulting from decreased spectacle dependence.

  5. Four-year follow-up of posterior chamber phakic intraocular lens implantation for moderate to high myopia.

    Science.gov (United States)

    Kamiya, Kazutaka; Shimizu, Kimiya; Igarashi, Akihito; Hikita, Fumika; Komatsu, Mari

    2009-07-01

    To assess the long-term clinical outcomes of implantation of a lens consisting of a biocompatible collagen copolymer (Visian implantable Collamer lens [ICL]; STAAR Surgical, Nidau, Switzerland) for moderate to high myopia. We evaluated 56 eyes of 34 patients with myopic refractive errors of -4.00 to -15.25 diopters (D) who underwent ICL implantation and routine postoperative examinations. Before and 1, 3, and 6 months and 1, 2, and 4 years after surgery, we assessed the safety, efficacy, predictability, stability, and adverse events of the surgery. Mean (SD) logMAR uncorrected and best spectacle-corrected visual acuities were -0.03 (0.23) and -0.21 (0.09), respectively, at 4 years after surgery. The mean (SD) safety and efficacy indexes were 1.19 (0.25) and 0.83 (0.29), respectively. At 4 years, 44 (79%) and 52 (93%) of the eyes were within +/-0.5 and +/-1.0 D, respectively, of the targeted correction. Mean (SD) manifest refraction changes of -0.24 (0.57) D occurred from 1 month to 4 years after surgery. No vision-threatening complications occurred during the observation period. Implantation of ICLs is safe and effective and provides predictable and stable refractive results in the treatment of moderate to high myopia during a 4-year observation period, suggesting its viability as a surgical option for the treatment of such eyes.

  6. [The Influence of risk factors on visual performance in of phototoxic maculopathy in occupational welders].

    Science.gov (United States)

    Li, Qingtao; Zhang, Xinfang

    2014-10-01

    To investigate the Influence of risk factors that cause the phototoxic maculopathy by welding arc in occupational welders. We examined randomly a group of 86 male occupational welders 172 eyes from some local metal manufacturing enterprise from August 2010 to December 2013. The ophthalmologic examination which the participants underwent thorough including the best visual acuity, fundus examination by the supplementary lens, fundus photography, and the high definition optical coherence tomography (OCT) scan. All participants of this study underwent thorough the medicine examined by a specialist of occupational who prior to the OCT. All the subjects were divided into groups according to age, protection degrees , length of service, operating time . The incidences of phototoxic maculopathy were compared within groups. The subjects was divided randomly into the lutein group and the placebo group. The examination including the best visual acuity, serum lutein concentrations, macular pigmentoptical density (MPOD), Contrast and glare Sensitivity. (1) The total incidence of phototoxic maculopathy is 32.0%. (2) The incidences of phototoxic maculopathy in the strict protection group, the randomed protective group and the nonprofessional protection group were respectively 21.4%, 36.7%, 53.6%. The incidence in the strict protection group was lower than the other two groups, the incidence was the highest in the nonprofessional protection group, and the difference was statistically significant. (3) The longer length of service, and operating time , the more incidence of phototoxic maculopathy develop. (4) The lutein group prior to the placebo group at the best visual acuity, serum lutein concentrations, macular pigmentoptical density (MPOD), Contrast and glare Sensitivity. The risk factors of phototoxic maculopathy in male occupational welders are the length of service, operating time, protection degrees and the lutein assistantly. The incidence of phototoxic maculopathy occurs

  7. Clinical research of limbal relaxing incision during implantable collamer lens surgery

    Directory of Open Access Journals (Sweden)

    Zhen Li

    2015-02-01

    Full Text Available AIM: To evaluate the efficacy and safety of limbal relaxing incision(LRIfor correcting corneal astigmatism during implantable collamer lens(ICLsurgery.METHODS: A total of 185 eyes of 105 patients with high myopia and corneal keratometric astigmatism were included in the study. ICL surgery with concomitant relaxing incision was performed in 105 eyes of 60 patients in LRIs group(Group A. Eighty eyes of 45 patients only underwent ICL surgery were in control group(Group B. All patients undergone ophthalmic examination that included uncorrected visual acuity(UCVA, best-corrected visual acuity(BCVA, Pentacam analysis system to observe the changes of corneal astigmatism before and 1wk, 1 and 3mo after surgery.RESULTS: Respectively comparing UCVA between two groups in 1 and 3mo postoperatively, the P values were considered statistically significant(PP values were considered no statistically significant(P>0.05. Preoperative corneal astigmatism was 1.52±0.55D in group A and 1.48±0.57D in group B, there was no statistically significant difference(P>0.05. One week postoperatively, the astigmatism was 0.55±0.41D in group A and 1.20±0.48D in group B. One month postoperatively, the astigmatism was 0.60±0.38D in group A and 0.93±0.47D. Three months postoperatively, the astigmatism was 0.51±0.32D in group A and 0.96±0.40D in group B. The difference between the two groups were statistically significant(PPPCONCLUSION: LRIs performed during ICL surgery appeared to be an effective and safer procedure to reduce pre-existing corneal astigmatism and improve UCVA as well as the visual quality.

  8. Scharioth Macula Lens: A new intraocular implant for low-vision patients with stabilized maculopathy- first experience.

    Science.gov (United States)

    Nekolova, Jana; Rozsival, Pavel; Sin, Martin; Jiraskova, Nada

    2017-06-01

    To present the initial results of Scharioth Macula Lens (SML) implantation. The SML is a new add-on intraocular lens designed to increase uncorrected near visual acuity (UCVA) in patients with stabilized maculopathy. Eight patients were included in the study. All met the indication criteria before SML implantation. An SML was implanted in the better seeing eye. Near and distance visual acuity were tested. Possible complications and patient complaints were recorded and patients were asked about their quality of vision after SML implantation. The examination was carried out on day 1, 1 week, 1, 3 and 6 months after surgery. Six-month-results are presented. Apart from one, all patients with the SML had good near visual acuity at a recommended reading distance of 15 cm. Preoperatively, the mean (min-max) near UCVA was J13 (J8-J16), mean distance BCVA was 0.27. Postoperatively, the best results were after 1 month - near UCVA was J2.5 (J1-J7), distance BCVA was 0.26. Three months after surgery, this decreased to J4.5 (J1-J8); distance VA remained 0.25. Six months postoperatively - near vision was J4 (J1-J8) and distance VA was unchanged. Patients reported problems with reading speed and reading distance. Daily exercise improved their reading ability. One patient converted to wet AMD 3 months post-implantation. The SML is a new hope for low-vision patients. It acts as a magnifier in the eye. It is a suitable method for increasing near visual acuity in patients with inactive maculopathy.

  9. Theoretical study on the need for laser iridotomy in an implantable collamer lens with a hole using computational fluid dynamics.

    Science.gov (United States)

    Kawamorita, T; Shimizu, K; Shoji, N

    2017-05-01

    PurposeAlthough one of the advantages of the Hole-ICL implantation is that laser iridotomy (LI) is unnecessary, the evidence have not been reported from the viewpoint of aqueous humor circulation. We investigated the effect of laser iridotomy (LI) on the fluid dynamics of aqueous humor in an implantable collamer lens (ICL) with a central hole, that is, a Hole-ICL using computational fluid dynamics.MethodsA fluid dynamics simulation was performed using the thermal-hydraulic analysis software FloEFD (Mentor Graphics Corp.). For the simulation, three-dimensional eye models with a conventional ICL (Model ICM, STAAR SURGICAL) and a Hole-ICL were used. The LI diameters were 250 and 500 μm. The flow distribution between the anterior surface of the crystalline lens and the posterior surface of the ICL was also calculated.ResultsThe flow velocity 0.25 mm in front of the center of the crystalline lens in the Hole-ICL without LI, with LI of 250 μm, and with LI of 500 μm was 1.48 × 10 -1 , 1.20 × 10 -1 , and 4.52 × 10 -2  mm/s, respectively. The flow velocity in the conventional ICL without LI, with LI of 250 μm, and with LI of 500 μm was 1.21 × 10 -5 , 3.60 × 10 -4 , and 6.33 × 10 -4  mm/s, respectively.ConclusionsThese results suggest that there is less need for LI in a posterior chamber phakic intraocular lens with a central hole from the viewpoint of aqueous humor circulation, although the results can be considered only in an ideal condition and further studies are needed to clarify the effect of LI in clinical practice.

  10. Posterior sclera reinforcement and phakic intraocular lens implantation for highly myopic amblyopia in children: a 3-year follow-up

    Science.gov (United States)

    Zhu, S-Q; Wang, Q-M; Xue, A-Q; Zheng, L-Y; Su, Y-F; Yu, A-Y

    2014-01-01

    Purpose To study the safety and efficacy of posterior scleral reinforcement (PSR) combined with phakic intraocular lens (PIOLs) implantation for highly myopic amblyopia in children. Methods This study included eight highly myopic children (11 eyes) who failed in conventional therapy for amblyopia using various combination of spectacles, contact lenses, and intensive patching before enrollment into this study. They were treated sequentially with PSR and PIOL implantation, and were followed up for 3 years after surgery. Uncorrected visual acuity (UCVA) and best corrected visual acuity (BCVA) in LogMAR, spherical equivalent power (SE), and complications were evaluated. Results Before surgery, the mean UCVA was 1.59±0.33, BCVA, 0.74±0.37, SE, −17.57±5.56D, the axial length (AL), 30.09±2.18 mm. After PSR, BCVA improved one line in three patients, the rest were unchanged, and AL was unchanged among all cases. Six eyes of three patients were implanted with an iris-claw PIOL and five eyes of five patients were implanted with a posterior PIOL. After completion of treatment, the mean UCVA was 0.44±0.21, BCVA 0.38±0.24, SE −0.54±0.74 D, and AL 30.35±2.29 mm. No patient experienced complications. Conclusion Combined PSR and PIOL implantation treatment for highly myopic amblyopia in children is safe and effective. PMID:25125071

  11. Primary versus secondary intraocular lens implantation in the management of congenital cataract

    Directory of Open Access Journals (Sweden)

    Thanaa H Mohamed

    2016-01-01

    Conclusion Primary IOL implantation was found to be safe and effective in the management of congenital cataract; it leads to lower incidence of complications and better visual outcomes compared with aphakia and secondary IOL implantation.

  12. Hydrophobic acrylic versus polymethyl methacrylate intraocular lens implantation following cataract surgery in the first year of life.

    Science.gov (United States)

    Ram, Jagat; Jain, Vaibhav K; Agarwal, Aniruddha; Kumar, Jaidrath

    2014-09-01

    To evaluate complication rates following implantation of hydrophobic acrylic versus polymethyl methacrylate (PMMA) intraocular lens (IOL) with cataract surgery in infants. Records of children undergoing cataract surgery with IOL implantation in first year of life were retrospectively reviewed. Infants were divided into two groups--hydrophobic acrylic IOLs were implanted in group A, and PMMA IOLs in group B. Outcome measures included incidence of complications, additional surgical procedures, and refractive error changes. One hundred and thirteen eyes of 113 children (75 males) with mean age of 6.49 ± 3.56 months were included. Group A included 62 eyes, and group B included 51 eyes. The two groups did not differ significantly in terms of age and axial length. There was no significant difference between the groups for incidence of posterior capsular opacification (PCO), pupillary membranes, glaucoma, fibrin on IOL surface or IOL malposition (p = 0.09). Development of PCO was delayed in group A (p = 0.049). Thirteen eyes of group A and 18 eyes of group B required additional surgical intervention (p = 0.20) in the follow-up visits. Comparable complications may be expected in infants with PMMA and hydrophobic acrylic lenses. Children implanted with PMMA IOLs may require earlier surgical re-intervention for PCO.

  13. Multiple methods of surgical treatment combined with primary IOL implantation on traumatic lens subluxation/dislocation in patients with secondary glaucoma.

    Science.gov (United States)

    Wang, Rui; Bi, Chun-Chao; Lei, Chun-Ling; Sun, Wen-Tao; Wang, Shan-Shan; Dong, Xiao-Juan

    2014-01-01

    To describe clinical findings and complications from cases of traumatic lens subluxation/dislocation in patients with secondary glaucoma, and discuss the multiple treating methods of operation combined with primary intraocular lens (IOL) implantation. Non-comparative retrospective observational case series. 30 cases (30 eyes) of lens subluxation/dislocation in patients with secondary glaucoma were investigated which accepted the surgical treatment by author in the Ophthalmology of Xi'an No.4 Hospital from 2007 to 2011. According to the different situations of lens subluxation/dislocation, various surgical procedures were performed such as crystalline lens phacoemulsification, crystalline lens phacoemulsification combined anterior vitrectomy, intracapsular cataract extraction combined anterior vitrectomy, lensectomy combined anterior vitrectomy though peripheral transparent cornea incision, pars plana lensectomy combined pars plana vitrectomy, and intravitreal cavity crystalline lens phacofragmentation combined pars plana vitrectomy. And whether to implement trabeculectomy depended on the different situations of secondary glaucoma. The posterior chamber intraocular lenses (PC-IOLs) were implanted in the capsular-bag or trassclerally sutured in the sulus decided by whether the capsular were present. visual acuity, intraocular pressure, the situation of intraocular lens and complications after the operations. The follow-up time was 11-36mo (21.4±7.13). Postoperative visual acuity of all eyes were improved; 28 cases maintained IOP below 21 mm Hg; 2 cases had slightly IOL subluxation, 4 cases had slightly tilted lens optical area; 1 case had postoperative choroidal detachment; 4 cases had postoperative corneal edema more than 1wk, but eventually recovered transparent; 2 cases had mild postoperative vitreous hemorrhage, and absorbed 4wk later. There was no postoperative retinal detachment, IOL dislocation, and endophthalmitis. To take early treatment of traumatic lens

  14. (Systemic) phototoxicity of drugs and other xenobiotics.

    Science.gov (United States)

    Beijersbergen van Henegouwen, G M

    1991-08-01

    Xenobiotics extensively used in drugs, cosmetics, food and agricultural chemicals can produce adverse biological effects. These toxic effects are separated into classes, e.g. hepatotoxicity, genotoxicity and neurotoxicity. Skin allergy, part of immunotoxicity, is also a subdivision of toxicology. When light is an essential condition for toxicity, the xenobiotic is called phototoxic. Thus it fits into the logic of toxicology that photoallergic compounds are a subdivision of phototoxic compounds. Phototoxicons as a group do not differ from the group of phototherapeutics with regard to their eventual biological effects. The primary photoreactions, secondary molecular processes, biomolecules involved and cellular and tissue damage are similar. The difference between the two groups is in the appreciation of the photobiological effects: adverse vs. desired. The aim of research is to determine the part of the molecular structure which makes a given compound phototoxic. With that knowledge the structure of the phototoxicon can be changed. This can result in a derivative which still has the desired properties of the parent compound, but is no longer phototoxic. This aim can be reached by combining data from both in vitro and in vivo research. The variety and number of phototoxic compounds is large. This, together with the limited research effort devoted to this subject so far, means that for most phototoxic xenobiotics a relationship between structure and in vivo photoreactivity is not available. In this review, emphasis is placed on xenobiotics whose in vitro and in vivo photochemistry have been studied. Furthermore, possible phototoxic effects which do not concern the skin but involve inner organs (systemic effects) are considered. References in this review mostly concern investigations over the last 10 years. For older literature or for additional information, references to other reviews are given. Important groups of phototoxic xenobiotics not dealt with in this article

  15. Management of moderate and severe corneal astigmatism with AcrySof® toric intraocular lens implantation - Our experience.

    Science.gov (United States)

    Farooqui, Javed Hussain; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2015-01-01

    Visual performance following toric intraocular lens implantation for cataract with moderate and severe astigmatism. Cataract services, Shroff Eye Centre, New Delhi, India. Case series. This prospective study included 64 eyes of 40 patients with more than 1.50 dioptre (D) of pre-existing corneal astigmatism undergoing phacoemulsification with implantation of the AcrySof® toric IntraOcular Lens (IOL). The unaided visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere and refractive cylinders were evaluated. Toric IOL axis and alignment error was measured by slit lamp method and Adobe Photoshop (version 7) method. Patient satisfaction was evaluated using a satisfaction questionnaire at 3 months. The mean residual refractive astigmatism was 0.57 D at the final follow-up of 3 months. Mean alignment error was 3.44 degrees (SD = 2.60) by slit lamp method and 3.88 degrees (SD = 2.86) by Photoshop method. Forty-six (71.9%) eyes showed misalignment of 5 degrees or less, and 60 (93.8%) eyes showed misalignment of 10 degrees or less. The mean log MAR UCVA at 1st post-op day was 0.172 (SD = 0.02), on 7th post-op day was 0.138 (SD = 0.11), and on 30th post-op day was 0.081 (SD = 0.11). The mean log MAR BCVA at three months was -0.04 (SD = 0.76). We believe that implantation of AcrySof® toric IOL is an effective, safe and predictable method to correct high amounts of corneal astigmatism during cataract surgery.

  16. Management of moderate and severe corneal astigmatism with AcrySof® toric intraocular lens implantation – Our experience

    Science.gov (United States)

    Farooqui, Javed Hussain; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2015-01-01

    Purpose Visual performance following toric intraocular lens implantation for cataract with moderate and severe astigmatism. Setting Cataract services, Shroff Eye Centre, New Delhi, India. Design Case series. Method This prospective study included 64 eyes of 40 patients with more than 1.50 dioptre (D) of pre-existing corneal astigmatism undergoing phacoemulsification with implantation of the AcrySof® toric IntraOcular Lens (IOL). The unaided visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere and refractive cylinders were evaluated. Toric IOL axis and alignment error was measured by slit lamp method and Adobe Photoshop (version 7) method. Patient satisfaction was evaluated using a satisfaction questionnaire at 3 months. Results The mean residual refractive astigmatism was 0.57 D at the final follow-up of 3 months. Mean alignment error was 3.44 degrees (SD = 2.60) by slit lamp method and 3.88 degrees (SD = 2.86) by Photoshop method. Forty-six (71.9%) eyes showed misalignment of 5 degrees or less, and 60 (93.8%) eyes showed misalignment of 10 degrees or less. The mean log MAR UCVA at 1st post-op day was 0.172 (SD = 0.02), on 7th post-op day was 0.138 (SD = 0.11), and on 30th post-op day was 0.081 (SD = 0.11). The mean log MAR BCVA at three months was −0.04 (SD = 0.76). Conclusion We believe that implantation of AcrySof® toric IOL is an effective, safe and predictable method to correct high amounts of corneal astigmatism during cataract surgery. PMID:26586976

  17. Cionni ring and in-the-bag intraocular lens implantation for subluxated lenses: a prospective case series.

    Science.gov (United States)

    Vasavada, Abhay R; Praveen, Mamidipudi R; Vasavada, Viraj A; Yeh, Ru-Yin; Srivastava, Samaresh; Koul, Archana; Trivedi, Rupal H

    2012-06-01

    To report the intraoperative performance and postoperative outcomes of the Cionni-modified capsule tension ring (CTR) implantation in eyes with subluxated lenses. Prospective, observational case series. This study was carried out at Iladevi Cataract & IOL Research Centre, Ahmedabad, India. The study population comprised 41 eyes with subluxated lenses that underwent lens extraction, capsular bag fixation with modified CTR, and in-the-bag single-piece AcrySof intraocular lens (IOL) implantation. Main outcome measures were intraoperative performance and postoperative best-corrected visual acuity (BCVA), IOL centration, and complications. The mean age was 29.46 ± 16.16 years (3-68 years). Mean extent of subluxation was 6.1 ± 1.0 clock hours. Preoperatively, vitreous was detected in the anterior chambers of 5 eyes (12.2%). Two-port anterior chamber vitrectomy was performed in 2 eyes. Mean follow-up was 45.8 ± 2.9 months. Mean preoperative BCVA was 0.66 ± 0.22 logMAR (35 eyes). Mean postoperative BCVA at final follow-up was 0.33 ± 0.21 logMAR (41 eyes) (P IOL decentration was noted and repositioning was required in 2 eyes. Posterior capsule opacification developed in 14 eyes (34.2%); 12 eyes (29.3%) required Nd:YAG capsulotomy. Other complications included cystoid macular edema in 1 eye (2.4%), posterior synechiae in 1 eye (2.4%), and retinal detachment in 1 eye (2.4%). In-the-bag implantation of a Cionni-modified CTR with IOL appears to be a safe option in eyes with subluxated cataract, ensuring a stable IOL with few complications. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Reverse pupillary block after implantation of a scleral-sutured posterior chamber intraocular lens: a retrospective, open study.

    Science.gov (United States)

    Bang, Seung Pil; Joo, Choun-Ki; Jun, Jong Hwa

    2017-03-29

    To report the clinical features of patients with reverse pupillary block (RPB) after scleral-sutured posterior chamber intraocular lens (PC IOL) implantation and biometric changes after laser peripheral iridotomy (LPI). Eight patients attending our hospital's ophthalmology outpatient clinic, who developed RPB after implantation of a scleral-sutured PC IOL due to subluxation of the crystalline lens or IOL, were investigated in this retrospective, observational study. Preoperative evaluations showed angle pigmentation in all cases and iridodonesis in 2 cases. Two subjects had used an α 1A -adrenoceptor antagonist for benign prostatic hyperplasia. Pars plana or anterior partial vitrectomy was performed in all cases. All eyes showed an extremely deep anterior chamber, a concave iris configuration, and contact between the IOL optic and the iris at the pupillary margin. Pupil capture was detected in 2 cases. The mean (± SD) anterior chamber angle (ACA) was 89.91 ± 10.06°, and the anterior chamber depth (ACD) was 4.42 ± 0.16 mm before LPI. After LPI, the iris immediately became flat with a decreased ACA (51.70 ± 2.59°; P = 0.018) and ACD (4.14 ± 0.15 mm; P = 0.012). After LPI, the intraocular pressure decreased from 19.75 ± 3.77 mmHg to 15.63 ± 4.30 mmHg (P = 0.011), and the spherical equivalent decreased from -0.643 ± 0.385 D to - 0.875 ± 0.505 D (P = 0.016). Concomitant vitrectomy, angle pigmentation, and iridodonesis may be risk factors for RPB after scleral-sutured PC IOL implantation. LPI is effective for relieving the RPB.

  19. Facoemulsificación e implante de lente intraocular en cataratas causadas por uveitis Phacoemulsification and intraocular lens implantation in patients with cataract caused by uveitis

    Directory of Open Access Journals (Sweden)

    Dayamí Pérez Gómez

    2008-06-01

    Full Text Available OBJETIVO: Evaluar los resultados de la facoemulsificación y el implante de lente intraocular en cataratas causadas por uveítis. MÉTODOS: Se estudiaron 37 ojos con 6 meses de inactividad inflamatoria, agudeza visual menor de 0,6 y edad media de 47 años. Se excluyeron otras enfermedades que disminuyeran la visión. En el preoperatorio se prescribió antiinflamatorios. Se realizó la facoemulsificación con implante de lente intarocular (PMMA, óptica 6 mm; durante el seguimiento desde 24 h/6 meses se indicó antiinflamatorios esteroideos, no esteroideos e inmunosupresores hasta 6 semanas. RESULTADOS: Se observaron numerosas alteraciones del segmento anterior secundarias a las uveítis padecidas (posquirúrgicas, inespecíficas, ciclítis heterocrómica de Fuchs, postraumáticas, síndrome de Reiter, por toxoplasmosis y otras coroiditis infecciosas y por artritis reumatoide juvenil. No hubo recurrencia posquirúrgica de la uveítis en 9 ojos (24,3 %. Las complicaciones estuvieron relacionadas con la uveítis, la cirugía, la actividad inflamatoria, y la reacción del epitelio capsular. La opacidad capsular posterior apareció en 11 pacientes (29,7 % asociada a edad joven. La evolución individual se consideró satisfactoria en 30 (81,1 % pacientes con mejoría de la visión hasta 0,8-1,0 en 28 (75,6 % y 0,5-0,6 en 2 (5,4 %. CONCLUSIONES: La facoemulsificación con implante de lente intarocular es de gran utilidad en las cataratas posuveítis al condicionar poca agresión quirúrgica, ser controlable la inflamación y proporcionar buenos resultados visuales además del reordenamiento anatomofisiológico del segmento anterior.OBJECTIVE: To assess the results of phacoemulsification and intraocular lens implantation in cataracts caused by uveitis. METHODS: Thirty seven eyes with no inflammation for 6 months, visual acuity below 0.6 and average age of 47 years were studied. Other diseases affecting the vision were excluded. The preoperative

  20. Intraocular dapiprazole for the reversal of mydriasis after extracapsular cataract extraction with intraocular lens implantation. Part II: Comparison with acetylcholine.

    Science.gov (United States)

    Ponte, F; Cillino, S; Faranda, F; Casanova, F; Cucco, F

    1991-11-01

    Intraocular dapiprazole for reversing mydriasis during extracapsular cataract extraction with intraocular lens (IOL) implantation has been compared to intraocular acetylcholine. Ninety patients were enrolled in a double-blind study and divided into three groups of 30 eyes; each group received balanced salt solution (control), 0.25% dapiprazole, or 1% acetylcholine. Pupillary diameter recordings were performed immediately before and a few minutes after drug injection, and two, four and eight hours after surgery. Goldmann tonometry was performed the day before and 6 and 24 hours after surgery. Contact endothelial cell count was performed before and one and four months after surgery. The results indicated a slower starting but longer lasting effect with dapiprazole than with acetylcholine and a significant reduction of the postoperative intraoperative pressure rise with both drugs. No significant difference in reduction in the endothelial cell count was seen between dapiprazole and acetylcholine groups and the control group.

  1. Clinical application of femtosecond laser assisted cataract surgery combined with triple-focus intraocular lens implantation in the treatment of cataract

    Directory of Open Access Journals (Sweden)

    Qing-Song Gao

    2018-02-01

    Full Text Available AIM:To evaluate the effect of femtosecond laser assisted cataract surgery combined with triple-focus intraocular lens implantation in the treatment of cataract. METHODS: Totally 86 cases(106 eyesof patients with double cataract in our hospital from January 2016 to January 2017 were selected, including 49 cases(59 eyeswere set as the observation group(treated with femtosecond laser assisted phacoemulsification combined with triple-focus intraocular lens implantation, and 37 cases(47 eyeswere set as the control group(received traditional phacoemulsification combined with triple-focus intraocular lens implantation. Corneal endothelial cell density, cumulative dissipated energy(CDE, distant and near visual accommodation before and after operation were compared between the two groups, postoperative complications were observed. RESULTS: The preoperative corneal endothelial cell density of two groups had no significant difference(P>0.05. The corneal endothelial cell density of two groups significantly decreased at postoperative 1wk, with statistic significance within groups(PPPPPP>0.05. The incidence of glare and halo in the observation group was 10.2% and 8.5% in the control group, and are in the patients whose age was above 60 years old, there was no significant difference between the two groups(P>0.05. CONCLUSION: Femtosecond laser assisted cataract surgery combined with triple-focus intraocular lens implantation in the treatment of cataract can not only improve curative effect, but also provide high safety, while the adverse events including glare, halo and other adverse visual circumstances should be considered after triple-focus intraocular lens implantation.

  2. Efficacy of different kinds of artificial tears treatment in patients with xerophthalmia after phacoemulsification combined with intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Yu-Xia Ruan

    2017-09-01

    Full Text Available AIM: To explore efficacy of the different kinds of artificial tears treatment in patients with xerophthalmia after phacoemulsification combined with intraocular lens implantation.METHODS: Totally 280 patients(280 eyeswith xerophthalmia after operation in our hospital from January 2015 to June 2016 were selected. According to the different treatment methods, they were divided into control group(n=70; treated with tobramycin and dexamethasone eye ointment 3 times per day for 1wk, levofloxacin eye drops 3 times per day for 1wk, pranoprofen eye drops 4 times per day for 1mo, polyacrylic acid group(n=70; besides the treatment of control group, polyacrylic acid was used 4 times per for 1mo, polyethylene glycol group(n=70; besides the treatment of control group, polyethylene glycol was used 4 times per for 1moand sodium hyaluronate group(n=70; besides the treatment of control group, sodium hyaluronate was used 4 times per for 1mo. The tear film break up time(BUT, Schirmer Ⅰ test(SⅠt, symptoms of dry eye and corneal staining in four groups were observed. RESULTS:(1BUT: The BUT of the four groups significantly increased after treatment(PPPPPPPPPPP>0.05; sodium hyaluronate group was significant lower than other groups in corneal staining score at 3wk and 1mo after treatment(PCONCLUSION: Artificial tears in the treatment of xerophthalmia after cataract phacoemulsification combined with intraocular lens implantation has better clinical efficacy, which contains sodium hyaluronate may be the better than others.

  3. Functional and refractive results after one month of AcrySof toric intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Francisco Alba-Bueno

    2011-04-01

    Conclusions: The implantation of SN60T toric IOL in patients with CA higher than 0.75 D is a safe, predictable and effective way of reducing refractive astigmatism in patients undergoing cataract surgery.

  4. Customized toric intraocular lens implantation for correction of extreme corneal astigmatism due to corneal scarring

    Directory of Open Access Journals (Sweden)

    R Bassily

    2010-03-01

    Full Text Available R Bassily, J LuckOphthalmology Department, Royal United Hospital, Combe Park, Bath, UKAbstract: A 76-year-old woman presented with decreased visual function due to cataract formation. Twenty-five years prior she developed right sided corneal ulceration that left her with 10.8 diopters (D of irregular astigmatism at 71.8° (steep axis. Her uncorrected visual acuity was 6/24 and could only ever wear a balanced lens due to the high cylindrical error. Cataract surgery was planned with a custom designed toric intraocular lens (IOL with +16.0 D sphere inserted via a wound at the steep axis of corneal astigmatism. Postoperative refraction was -0.75/+1.50 × 177° with a visual acuity of 6/9 that has remained unchanged at six-week follow-up with no IOL rotation. This case demonstrates the value of high power toric IOLs for the correction of pathological corneal astigmatism.Keywords: intraocular lens, corneal ulceration, visual acuity, scarring

  5. Low-cost high-volume extracapsular cataract extraction with posterior chamber intraocular lens implantation in Nepal.

    Science.gov (United States)

    Ruit, S; Tabin, G C; Nissman, S A; Paudyal, G; Gurung, R

    1999-10-01

    To improve current clinical practices and ways of thinking about the problem of curable Third-World blindness resulting from cataract. A two-site prospective, nonrandomized, comparative clinical trial. Patients from 2 distinct surgical venues underwent cataract surgery following the same carefully outlined protocol: 62 consecutive cases from the Tilganga Eye Centre in Katmandu, Nepal, and 207 cases from a remote eye camp in rural Chaughada, Nepal. Extracapsular cataract extraction with posterior chamber intraocular lens (IOL) implantation surgery using a technique developed by Dr. Sanduk Ruit of the Tilganga Eye Centre in conjunction with the Medical Directorate of the Fred Hollows Foundation of Australia. Also presented is the teaching method used to help make local doctors proficient in this technique. Visual acuity recorded at 2 months after surgery as well as surgical complications. Preoperative visual acuities for the 62 patients from the Tilganga Eye Centre ranged from 20/60 to light perception only (4 patients were untested). At 2 months after surgery, 87.1% had a best-corrected visual acuity of 20/60 or better. There were zero major surgical complications reported from the Tilganga group. Of the 207 patients at the Chaughada eye camp, preoperative visual acuities (recorded for 177 [85.5%]) ranged from 20/200 or greater to light perception only. One hundred eighty-nine (91.3%) of the patients returned for an examination at 2 months after surgery, at which time 54.5% had an uncorrected visual acuity of 20/60 or greater, improving to 74.1% with correction. There were six (2.9%) surgical complications documented at Chaughada. Because the average operative time using the technique presented here is less than 10 minutes per case and the cost per surgery is less than $20, the surgical results are significant in addressing the massive problem of cataract blindness in the Third World. With some changes in preoperative care, a simplified surgical technique, the

  6. Comparison of two different methods of preoperative marking for toric intraocular lens implantation: bubble marker versus pendulum marker

    Directory of Open Access Journals (Sweden)

    Javed Hussain Farooqui

    2016-05-01

    Full Text Available AIM: To compare the accuracy of two different methods of preoperative marking for toric intraocular lens (IOL implantation, bubble marker versus pendulum marker, as a means of establishing the reference point for the final alignment of the toric IOL to achieve an outcome as close as possible to emmetropia. METHODS: Toric IOLs were implanted in 180 eyes of 110 patients. One group (55 patients had preoperative marking of both eyes done with bubble marker (ASICO AE-2791TBL and the other group (55 patients with pendulum marker (Rumex(3-193. Reference marks were placed at 3-, 6-, and 9-o'clock positions on the limbus. Slit-lamp photographs were analyzed using Adobe Photoshop (version 7.0. Amount of alignment error (in degrees induced in each group was measured. RESULTS: Mean absolute rotation error in the preoperative marking in the horizontal axis was 2.42±1.71 in the bubble marker group and 2.83±2.31in the pendulum marker group (P=0.501. Sixty percent of the pendulum group and 70% of the bubble group had rotation error ≤3 (P=0.589, and 90% eyes of the pendulum group and 96.7% of the bubble group had rotation error ≤5 (P=0.612. CONCLUSION: Both preoperative marking techniques result in approximately 3 of alignment error. Both marking techniques are simple, predictable, reproducible and easy to perform.

  7. Quality of vision in patients implanted with aspherical and spherical intraocular lens: Intraindividual comparison

    Directory of Open Access Journals (Sweden)

    Francesco Semeraro

    2014-01-01

    Full Text Available Aims: To compare the quality of vision in pseudophakic patients implanted with aspherical and spherical intraocular lenses (IOLs. Materials and Methods: Randomized prospective longitudinal intrapatient comparison between aspherical and spherical IOLs performed on 22 patients who underwent bilateral cataract surgery. Best corrected visual acuity, subjective contrast sensitivity, Strehl ratio and spherical aberrations (SA, and higher order wavefront aberrations for a 3.5 mm and a 6.0 mm pupil were measured after 3 months of cataract surgery. Results: SA (Z4,0 decreased significantly in eyes with aspherical IOL implant (P = 0.004. Modulation transfer function (MTF and point spread function (PSF resulted no significant difference between the two groups (P = 0.87; P = 0.32. Conclusion: Although the SA is significantly lower in eyes implanted with aspherical IOL, the quality of vision determined with MTF and PSF does not significantly differ for subjective and objective parameters that were analyzed.

  8. Outcomes and possible risk factors associated with axis alignment and rotational stability after implantation of the Toric implantable collamer lens for high myopic astigmatism.

    Science.gov (United States)

    Sheng, Xun-Lun; Rong, Wei-Ning; Jia, Qin; Liu, Ya-Ni; Zhuang, Wen-Juan; Gu, Qing; Sun, Yan; Pan, Bo; Zhu, De-Jun

    2012-01-01

    To assess the visual outcomes and possible risk factors associated with axis alignment and rotational stability after implantation of Toric implantable collamer lens (TICL) for the correction of high myopic astigmatism. In this prospective, nonrandomized clinical study, 54 consecutive eyes of 29 patients with high myopic astigmatism received TICL implantation. To evaluate postoperative axis deviation from the intended axis, a digital anterior segment photograph was taken. The ultrasound biomicroscopy(UBM) was used to observe footplate-position. After mean follow-up of 8.6 months, mean manifest refractive cylinder (MRC) decreased 79.3% from (-1.88±1.49)D preoperatively to (0.39±0.61)D postoperatively. MRC within 1.00 D occurred in 68.5% (37/54) of eyes, whereas 48.1% (26/54) had MRC within 0.50 D. Mean manifest refraction spherical equivalent (MRSE) changed from (-12.08±4.22)D preoperatively to (-0.41±0.61)D postoperatively. Uncorrected binocular vision of 20/20 or better occurred in 72.2% (39/54) of patients compared with binocular best-corrected visual acuity (BCVA) of 20/20 or better in 44.4% (24/54) preoperatively. The mean difference between intended and achieved TICL axes was (6.96±8.37)°. Footplates of TICLs were in the ciliary sulcus in 22 eyes (46.3%), below the ciliary sulcus in 32 eyes (53.7%). The angle of TICL rotation had significant correlation with the footplates-position (t=2.127; P=0.045) and the postoperative TICL vaulting (r=-0.516; P=0.000). The results of our study further support the safety, efficacy and predictability of TICL for the correct high myopic astigmatism. The footplate-position of TICL and vault value should be taken into consideration as two possible risks factors for TICL rotation.

  9. Complications and visual outcomes after glued foldable intraocular lens implantation in eyes with inadequate capsules.

    Science.gov (United States)

    Kumar, Dhivya Ashok; Agarwal, Amar; Packiyalakshmi, Sathiya; Jacob, Soosan; Agarwal, Athiya

    2013-08-01

    To evaluate the complications and visual outcomes of glued intrascleral-fixated foldable intraocular lens (IOL) in eyes with deficient capsules. Dr Agarwal's Eye Hospital and Eye Research Centre, Chennai, India. Case series. Data were evaluated from the records of patients with a primary glued foldable IOL for intraoperative capsular loss or subluxated lens or secondary glued foldable IOL for aphakia. Exclusion criteria included preoperative glaucoma, aniridia, macular scar, traumatic subluxation, combined surgeries, incomplete operative medical records, and postoperative follow-up less than 6 months. The intraoperative and postoperative complication rates, reoperation rate, and visual outcomes were analyzed. The study comprised 208 eyes (185 patients). The mean follow-up was 16.7 months ± 10.2 (SD). The intraoperative complications were hyphema (0.4%), haptic breakage (0.4%), and deformed haptics (0.9%). Early complications occurred in 29 eyes (13.9%) and included corneal edema (5.7%), epithelial defect (1.9%), and grade 2 anterior chamber reaction (2.4%). Late complications occurred in 39 eyes (18.7%) and included optic capture (4.3%), IOL decentration (3.3%), haptic extrusion (1.9%), subconjunctival haptic (1.4%), macular edema (1.9%), and pigment dispersion (1.9%). Reoperation was required in 16 eyes (7.7%). Haptic position was altered in eyes with IOL decentration. Corrected distance visual acuity (CDVA) improved or remained unchanged in 84.6% of eyes. The postoperative CDVA was 20/40 or better and 20/60 or better in 38.9% and 48.5% of eyes, respectively. The foldable glued-IOL procedure showed satisfactory visual outcomes without serious complications. Intraocular lens decentration was due to haptic-related problems. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. Variations in retinal nerve fiber layer measurements on optical coherence tomography after implantation of trifocal intraocular lens.

    Science.gov (United States)

    García-Bella, Javier; Martínez de la Casa, José M; Talavero González, Paula; Fernández-Vigo, José I; Valcarce Rial, Laura; García-Feijóo, Julián

    2018-01-01

    To establish the changes produced after implantation of a trifocal intraocular lens (IOL) on retinal nerve fiber layer measurements performed with Fourier-domain optical coherence tomography (OCT). This prospective study included 100 eyes of 50 patients with bilateral cataract in surgical range, no other associated ocular involvement, refractive errors between +5 and -5 spherical diopters, and less than 1.5 D of corneal astigmatism. The eyes were operated by phacoemulsification with implantation of 2 different trifocal IOLs (FineVision and AT LISA tri 839MP) in randomized equal groups. Cirrus OCT and Spectralis OCT were performed before surgery and 3 months later. Both analyzed the thickness of the nerve fiber layer and thickness divided by quadrants (6 in case of Spectralis and 4 in case of Cirrus HD). The mean age of patients was 67.5 ± 5.8 years. The global nerve fiber layer thickness measured with Spectralis OCT was 96.77 μm before surgery and 99.55 μm after. With Cirrus OCT, the global thickness was 85.29 μm before surgery and 89.77 μm after. Statistically significant differences in global thickness measurements between preimplantation and postimplantation of the IOL were found with both OCT in the 2 groups. Statistically significant differences were also found in temporal and superior quadrants. The implantation of a diffractive trifocal IOL alters the results of the optic nerve fiber layer on Fourier-domain OCT in these patients, which should be taken into account in the posterior study of these patients.

  11. Optical analysis, reading performance, and quality-of-life evaluation after implantation of a diffractive multifocal intraocular lens.

    Science.gov (United States)

    Alió, Jorge L; Plaza-Puche, Ana B; Piñero, David P; Amparo, Francisco; Jiménez, Ramón; Rodríguez-Prats, Jose L; Javaloy, Jaime; Pongo, Vanessa

    2011-01-01

    To evaluate the reading performance, changes in quality of life, and optical performance after cataract surgery with multifocal diffractive intraocular lens (IOL) implantation. Vissum Corporation, Alicante, Spain. Prospective case series. Patients with bilateral cataract had implantation of Acri.LISA 366D multifocal IOLs. Visual acuity and contrast sensitivity outcomes were evaluated during a 6-month follow-up. Other parameters evaluated included reading performance (Salzburg Reading Desk), a 25-item quality-of-life questionnaire (National Eye Institute Visual Functioning Questionnaire-25 [NEI VFQ-25] and appendix NEI VFQ-39), and ocular optical performance (ocular aberrometry and modulation transfer function). The study included 48 eyes (24 patients) ranging in age from 47 to 77 years. The mean uncorrected distance visual acuity (logMAR) improved significantly 1 month postoperatively (P<.01), with no significant changes afterward (6 months, P≥.06). The mean reading acuity without correction improved significantly from 0.68 logRAD ± 0.20 (SD) to 0.16 ± 0.08 logRAD 1 month after surgery (P < .01). However, it was worse by the end of the follow-up (6 months, P = .04). During the follow-up, no significant changes were found in the mean reading speed without near correction (6 months, P = .50). Contrast sensitivity improved significantly at all spatial frequencies under photopic and scotopic conditions after surgery (6 months, P≤.02). The quality-of-life index related to reading ability also improved significantly (3 months, P = .03). Implantation of the multifocal diffractive IOL significantly improved reading performance, which had a positive effect on the patient's quality of life postoperatively. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  12. Multiple methods of surgical treatment combined with primary IOL implantation on traumatic lens subluxation/dislocation in patients with secondary glaucoma

    Directory of Open Access Journals (Sweden)

    Rui Wang

    2014-04-01

    Full Text Available AIM:To describe clinical findings and complications from cases of traumatic lens subluxation/dislocation in patients with secondary glaucoma, and discuss the multiple treating methods of operation combined with primary intraocular lens (IOL implantation.METHODS:Non-comparative retrospective observational case series. Participants:30 cases (30 eyes of lens subluxation/dislocation in patients with secondary glaucoma were investigated which accepted the surgical treatment by author in the Ophthalmology of Xi''an No.4 Hospital from 2007 to 2011. According to the different situations of lens subluxation/dislocation, various surgical procedures were performed such as crystalline lens phacoemulsification, crystalline lens phacoemulsification combined anterior vitrectomy, intracapsular cataract extraction combined anterior vitrectomy, lensectomy combined anterior vitrectomy though peripheral transparent cornea incision, pars plana lensectomy combined pars plana vitrectomy, and intravitreal cavity crystalline lens phacofragmentation combined pars plana vitrectomy. And whether to implement trabeculectomy depended on the different situations of secondary glaucoma. The posterior chamber intraocular lenses (PC-IOLs were implanted in the capsular-bag or trassclerally sutured in the sulus decided by whether the capsular were present. Main outcome measures:visual acuity, intraocular pressure, the situation of intraocular lens and complications after the operations.RESULTS: The follow-up time was 11-36mo (21.4±7.13. Postoperative visual acuity of all eyes were improved; 28 cases maintained IOP below 21 mm Hg; 2 cases had slightly IOL subluxation, 4 cases had slightly tilted lens optical area; 1 case had postoperative choroidal detachment; 4 cases had postoperative corneal edema more than 1wk, but eventually recovered transparent; 2 cases had mild postoperative vitreous hemorrhage, and absorbed 4wk later. There was no postoperative retinal detachment, IOL

  13. Comparison of visual outcomes and subjective visual quality after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of apodized diffractive bifocal intraocular lenses

    Directory of Open Access Journals (Sweden)

    Gundersen KG

    2016-05-01

    Full Text Available Kjell G Gundersen,1 Rick Potvin21IFocus Øyeklinikk AS, Haugesund, Norway; 2Science in Vision, Akron, NY, USAPurpose: To compare the visual acuity (VA and quality of vision between bilateral implantation of a trifocal intraocular lens (IOL and blended bifocal IOLs with an intermediate add in the dominant eye and a near add in the nondominant eye.Patients and methods: Patients with either trifocal or blended bifocal IOLs implanted were recruited after surgery. Subjects returned for a single diagnostic visit between 3 and 24 months after surgery. VA was tested at various distances, including low-contrast acuity and acuity at their preferred reading distance. A binocular defocus curve was obtained, and subjective visual function and quality of vision were evaluated.Results: Twenty-five trifocal subjects and 30 blended bifocal subjects were enrolled. There were no significant differences in low-contrast acuity, preferred reading distance, or acuity at that reading distance. Binocular vision at 4 m, 60 cm, and 40 cm was not statistically significantly different. The trifocal provided statistically significantly better visual acuity (P<0.05 at vergences from -0.5 to -1.5 D (from 2 m to 67 cm viewing distance, P<0.05. There was no statistically significant difference in the near vision subscale scores of the 39-question National Eye Institute Visual Function Questionnaire or the overall scores of the Quality of Vision questionnaire, though significantly more trifocal subjects reported that the observed visual disturbances were “bothersome” (P<0.05.Conclusion: Both lens modalities provided subjects with excellent binocular near and distance vision, with similar low rates of visual disturbances and good reported functional vision. The trifocal IOL provided significantly better intermediate VA in the viewing distance range of 2 m to 67 cm, corresponding to viewing things such as a car dashboard or grocery shelf. VA was similar between groups at

  14. Outcomes of scleral-sutured conventional and aniridia intraocular lens implantation performed in a university hospital setting.

    Science.gov (United States)

    Lockington, David; Ali, Noor Q; Al-Taie, Rasha; Patel, Dipika V; McGhee, Charles N J

    2014-04-01

    To evaluate the outcomes of transscleral sutured posterior chamber intraocular lens (PC IOL) implantation. Public university hospital, Auckland, New Zealand. Retrospective case series. A modified no-touch transscleral sutured PC IOL implantation technique with a 1-piece monofocal IOL (Alcon CZ70BD) or an aniridia IOL (type 67G, Morcher) was assessed. Seventy-eight cases (80.8% men; 53.9% aphakic) were identified. The mean follow-up was 35.5 months and the mean age at surgery, 41 years±21 (SD). The preoperative corrected distance visual acuity (CDVA) was worse than 6/30 in 66.7%. Indications included ocular trauma (46.2%), nontraumatic crystalline lens subluxation (16.7%), post-complicated cataract surgery (10.3%), idiopathic IOL dislocation (10.3%), and congenital cataract/aphakia (10.3%). An aniridia IOL was required in 39.7% of eyes. There were no significant intraoperative complications in 74.4% of eyes. Postoperative complications included transient corneal edema (15.4%), wound leak requiring resuturing (7.7%), retinal detachment (7.7%), and cystoid macular edema (6.4%). One eye (1.3%) developed suture breakage-related late IOL dislocation. Overall, 91.3% of eyes had improved visual acuity or were within 1 line of the presenting CDVA. In eyes with a guarded prognosis, 34.8% achieved a CDVA of 6/12 or better and 43.5% a CDVA of 6/15 to 6/48. In the better prognosis group, 73.9% achieved a CDVA of better than 6/12 and all achieved better than 6/30. Scleral-sutured IOLs achieved good visual outcomes in a public hospital setting. The rate of complications was moderate in this series with a high proportion of severe ocular trauma and a large percentage of aniridia IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  15. Comparison of the Results of Secondary Anterior Chamber and Secondary Scleral-Fixated Intraocular Lens Implantation in Complicated Phacoemulsification Cases

    Directory of Open Access Journals (Sweden)

    Nimet Yeşim Erçalık

    2014-03-01

    Full Text Available Objectives: To compare the visual prognosis and postoperative complication rates of secondary anterior chamber (AC IOL and scleralfixated (SF intraocular lenses (IOL after complicated phacoemulsification surgery. Materials and Methods: Thirty eyes of thirty patients were reviewed for this retrospective study. The patients with secondary AC IOL implantation formed group 1 (n=15, and the patients with secondary SF IOL implantation formed group 2 (n=15. Best-corrected visual acuity (BCVA with Snellen chart, biomicroscopic examination, intraocular pressure (IOP measurement with applanation tonometer, gonioscopy performed by Goldmann’s 3-mirror contact lens, and fundus examination were performed preoperatively in all patients. Results: There was no statistically significant difference in postoperative BCVA (p=0.492 and postoperative success (BCVA not changed or better postoperatively between the 2 groups (p=0.598. Postoperative success rate was 80% in group 1 and 93.7% in Group 2. The postoperative cylindrical power of the eyes did not differ significantly between the groups (p=0.220. The postoperative complications in group 1 were as follows: transient corneal edema in 5 eyes, transient IOP elevation in 2 eyes, postoperative fibrinous reaction in the anterior chamber in one eye, late-onset secondary glaucoma in one eye, hyphema in one eye, cystoid macular edema in one eye, vitreous prolapse into the anterior chamber in one eye, and IOL malposition in one eye. The postoperative complications in group 2 were as follows: transient corneal edema in 3 eyes, vitreous prolapse into the anterior chamber in 2 eyes, IOL malposition in 2 eyes, transient IOP elevation in one eye, and retinal detachment in one eye. Conclusion: In this study, both IOL types were observed to be preferable in cases without adequate capsular support following complicated cataract surgery. However, further studies with large numbers of patients are needed to define the best choice

  16. Implantation of ArtificialIris, a CustomFlex irisprosthesis, in a trauma patient with an Artisan lens: A case report and review.

    Science.gov (United States)

    Doroodgar, Farideh; Jabbarvand, Mahmoud; Niazi, Feizollah; Niazi, Sana; Sanginabadi, Azad

    2017-11-01

    To evaluate probable complications of ArtificialIris implantation with iris fixated intraocular lens. Development of photophobia, glare, and psychological strain during face-to-face communication in a 23-year-old man with a widespread traumatic iris defect terminate to make a decision for performing implantation of an ArtificialIris (Humanoptics, Erlangen, Germany) under the remnant iris without removing the patient's existing Artisan lens. Without any intraoperative or postoperative complications, the patient's visual acuity increased by 1 line, the endothelial cell loss was comparable with the cell loss associated with standard cataract surgery, and the anterior-chamber depth and anterior-chamber anatomy did not change. At the final follow-up examination, the mean intraocular pressure did not differ from baseline, and we achieved high level of patient satisfaction and subjective vision improvement. We discuss the particular importance of considering the patient's expectations, the appropriate measurements, ways to perfect color evaluation, and the types of ArtificialIris products. The implantation of the ArtificialIris in patients with aphakic iris-supported lenses (ie, pre-existing Artisan lenses) is a feasible approach and a useful option for patients with thin irises and iris hypoplasia who are at risk of subluxation or the dislocation of the posterior-chamber intraocular lens (PCIOL), and also those with sclerally fixed PCIOLs.

  17. Clinical observation of small-incision extracapsular cataract extraction with intraocular lens implantation for the treatment of cataract in the sight restoration project

    Directory of Open Access Journals (Sweden)

    Xiao-Jian Cheng

    2014-04-01

    Full Text Available AIM: To analyze the clinical effects of small-incision extracapsular cataract extraction with intraocular lens implantation for the treatment of cataract.METHODS:Totally 642 cases 676 eyes of cataract were treated by small-incision extracapsular cataract extraction with intraocular lens implantation. Complication during and after operations and postoperative visual acuity was observed.RESULTS:Visual acuity of 670 eyes was ≥0.05 and off-blindness rate was 99.11%, and there was 627 eyes ≥0.3 and the off-disability rate was 92.75% after 1mo. Rupture of posterior capsule during surgery occurred in 24 eyes. Fifty-four eyes were corneal edema, and anterior chamber exudation were 26 eyes, and 23 eyes were hypertension after operation. CONCLUSION: There are a little complications during and after operation for cataract treated by small-incision extracapsular cataract extraction with intraocular lens implantation. Patients have good recovery after operation. This operation does not need high-standard equipments and is suitable in the sight restoration project.

  18. Risk factors of persistent diplopia following secondary intraocular lens implantation in patients with sensory strabismus from uncorrected monocular aphakia.

    Science.gov (United States)

    Ahn, Ye Jin; Park, Shin Hae; Shin, Sun Young

    2016-01-01

    We aimed to compare clinical characteristics between diplopia-free and diplopia-persistent patients after successful strabismus surgery, when patients complained of diplopia following secondary intraocular lens (IOL) implantation after prolonged aphakia accompanied by sensory strabismus. Retrospective review of medical records of patients who complained of diplopia following secondary IOL placement with sensory strabismus after prolonged uncorrected monocular aphakia from isolated ocular trauma was done. We classified patients into two groups according to persistency of diplopia, 6 months after successful strabismus surgery. Clinical characteristics were compared between groups. A total of 31 patients were included. The diplopia-persistent group showed longer duration of uncorrected aphakia (p = 0.02), less severe corneal astigmatism (p = 0.04), a smaller exodeviation angle (p = 0.02), and more frequent vertical deviation (p = 0.015), extorsion (p = 0.022) and monocular nystagmus (p = 0.028) than the diplopia-free group. In all patients in the diplopia-free group, diplopia could be eliminated prior to strabismus surgery using loose prisms in free space, whereas seven patients in the diplopia-persistent group prior to surgery could not resolve diplopia. Our data will be helpful for ocular surgeons in determining whether to insert secondary IOL in prolonged aphakia with sensory strabismus, or whether strabismus surgery will eliminate diplopia that develops following secondary IOL placement in this situation.

  19. Rotational stability and visual quality in eyes with Rayner toric intraocular lens implantation.

    Science.gov (United States)

    Alberdi, Txomin; Macías-Murelaga, Beatriz; Bascarán, Lucía; Goñi, Nahia; de Arregui, Sandra Sáez; Mendicute, Javier

    2012-10-01

    To assess astigmatic reduction and rotational stability of Rayner T-flex toric intraocular lenses (IOL) (573T and 623T; Rayner Intraocular Lenses Ltd) in a series of cataract surgery patients with corneal astigmatism >1.50 diopters (D). This prospective, observational study included 27 eyes from 22 consecutive patients with pre-operative regular corneal astigmatism ≥1.50 D in which Rayner T-flex toric IOL implantation was performed after phacoemulsification. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), residual refractive sphere, residual keratometric and refractive cylinder, and deviation from attempted toric IOL axis were measured. Mean UDVA 3 months after surgery was 0.1042±0.1290 with 20/40 or better in 96% of eyes and 20/25 or better in 52% of eyes. Mean refractive postoperative sphere was 0.25±0.37 D and mean refractive postoperative cylinder was 0.52±0.63 D. Vector analysis of attempted versus achieved visual correction showed that 100% of eyes were within ±1.00 D and 87% of eyes were within ±0.50 D. Mean change in keratometric astigmatism was 0.54±1.33 for J(0) and -0.24±1.17 for J(45) (P>.05). Twenty-five (92.6%) eyes had IOL rotation <10°. Rayner T-flex toric IOL implantation is an effective and reliable option to correct preexisting astigmatism in cataract surgery. Copyright 2012, SLACK Incorporated.

  20. Comparison of Reading Speed after Bilateral Bifocal and Trifocal Intraocular Lens Implantation.

    Science.gov (United States)

    Kim, Moses; Kim, Jae Hyung; Lim, Tae Hyung; Cho, Beom Jin

    2018-03-19

    To evaluate and compare visual acuity and reading speed for Korean language between a diffractive bifocal and trifocal intraocular lens (IOL) of the same material and haptic design. We reviewed the medical records of the patients who had undergone bilateral cataract surgery with bifocal IOLs (AT LISA 801) on the both eyes (bifocal group) and trifocal IOLs (AT LISA tri 839 MP, trifocal group). The main outcome measures were the uncorrected distance, intermediate, and near visual acuity (uncorrected distance visual acuity [UCDVA], uncorrected intermediate visual acuity [UCIVA], and uncorrected near visual acuity [UCNVA]) and corrected distance, near, and distance-corrected intermediate visual acuity (corrected distance visual acuity [CDVA], corrected near visual acuity [CNVA], and distance-corrected intermediate visual acuity [DCIVA]) at last postoperative follow-up month. Reading speeds for Korean language were measured to check near visual function. Fourteen eyes (7 patients) were included in the bifocal group and 32 eyes of 16 patients in the trifocal group. There were no statistical differences between the two groups with respect to UCDVA, UCNVA, CDVA, and CNVA. However, UCIVA (0.35 vs. 0.22 logarithm of the minimum angle of resolution [logMAR], p reading speed for logMAR 0.5 optotype (point 10) was 86.50 words per minute (wpm) in the bifocal group and 81.48 wpm in the trifocal group without a significant difference (p = 0.70). Trifocal IOLs provided the same level of distance and near visual acuity and reading speed as that of bifocal IOLs with better intermediate visual acuity. © 2018 The Korean Ophthalmological Society.

  1. Safety and effect of femtosecond laser-assisted cataract surgery combined with Cionni capsular tension ring implantation in the management of traumatic lens subluxation

    Directory of Open Access Journals (Sweden)

    Jia-Hui Chen

    2017-07-01

    Full Text Available AIM:To investigate the safety and effect of femtosecond laser-assisted cataract surgery with Cionni modified capsular tension ring(MCTRimplantation in the management of traumatic lens subluxation.METHODS: Totally 11 patients(11 eyeswith traumatic lens subluxation were divided into three groups according to the severity of lens dislocation, ranging from 90° to 120°(4 eyes, 120° to 180°(5 eyesand 180° to 270°(2 eyes. The contact LenSx femtosecond laser cataract surgery platform was applied to create the capsulotomy, prepare nuclear fragmentation and make corneal wound creation. Anterior vitrectomy was performed in some patients during the surgery. After capsular retractors insertion and phacoemulsification, the MCTR was inserted to the capsular bag and fixed to the sclera. Finally, the IOL was implanted into the capsular bag. Postoperative visual acuity, intra- and post-operative complications, anterior capsular opening, IOL and MCTR position and intraocular pressure(IOPwere assessed.RESULTS:The duration of follow-up was 2mo. All the operations were completed successfully. Five eyes underwent cataract surgery combined with anterior vitrectomy. Four eyes had been inserted with 2-eyelet MCTR and seven eyes with 1-eyelet MCTR. The best corrected visual acuity(BCVAafter operation was better than 0.5 in 4 eyes, between 0.3 and 0.5 in 3 eyes, between 0.1 and 0.3 in 3 eyes, and less than 0.1 in 1 eye. Compared with preoperative BCVA, the difference was statistically significant(PCONCLUSION:Femtosecond laser-assisted cataract surgery can improve the success rate of capsulorhexis, and reduce the difficulty of nuclear fragmentation. Femtosecond laser-assisted cataract surgery combined with MCTR implantation is an ideal surgical method for traumatic lens subluxation.

  2. Desempenho visual após implante de uma lente intraocular asférica multifocal difrativa Visual performance after implantation of an aspheric multifocal diffractive intraocular lens

    Directory of Open Access Journals (Sweden)

    Leonardo Akaishi

    2010-08-01

    Full Text Available OBJETIVO: Avaliar a acuidade visual a distancia, intermediária e perto após o implante de uma lente intraocular (LIO asférica multifocal difrativa AcrySof® ReSTOR® SN6AD1. MÉTODOS: Estudo prospectivo de 50 pacientes com catarata submetidos à facoemulsificação e implante de LIO AcrySof® ReSTOR®. Foram avaliados acuidade visual sem correção (AVSC, acuidade visual com correção (AVCC para longe, acuidade visual para perto corrigida para longe (AVPC e acuidade visual intermediária corrigida para longe (AVIC. Um questionário de satisfação e fenômenos visuais foi administrado ao final do estudo. RESULTADO: Após três meses de cirurgia, a média das acuidades (logMAR era: AVSC, 0,05 ± 0,07; AVCC, 0,00 ± 0,01; AVPC, 0,00 ± 0,0, e AVIC, 0,15 ± 0,05. A AVCC e AVPC era de 20/25 ou melhor em todos os pacientes, sendo a AVIC J3 ou melhor em 83% dos pacientes. Pacientes relataram excelente desempenho visual nas questões relacionadas a atividades para distância, intermediário, e perto com pouca ou nenhuma dificuldade. Nenhum paciente relatou halos ou 'glare' severos, sendo os mesmos caracterizados entre nenhum a moderado. CONCLUSÃO: A LIO asférica AcrySof® ReSTOR® SN6AD1 mostrou excelentes resultados na visão para longe, perto e intermediário, além de apresentar uma baixa incidência de fenômenos visuais.PURPOSE: To evaluate distance, intermediate, and near vision after aspheric multifocal diffractive AcrySof® ReSTOR® SN6AD1 intraocular lens (IOL implantation. METHODS: Prospective study of 50 patients with cataract that had phacoemulsification and AcrySof® ReSTOR® IOL implantation. Uncorrected distance vision acuity (UDVA, corrected distance visual acuity (CDVA, distance-corrected near visual acuity (DCNVA, and distance-corrected intermediate visual acuity (DCIVA were measured postoperatively. A patient-satisfaction and visual phenomena questionnaire was administered at the end of the study. RESULTS: Three months

  3. Comparative analysis of the visual performance after implantation of the toric implantable collamer lens in stable keratoconus: a 4-year follow-up after sequential procedure (CXL+TICL implantation).

    Science.gov (United States)

    Doroodgar, Farideh; Niazi, Feazollah; Sanginabadi, Azad; Niazi, Sana; Baradaran-Rafii, Alireza; Alinia, Cyrus; Azargashb, Eznollah; Ghoreishi, Mohammad

    2017-01-01

    To report on 4-year postoperative visual performance with the toric implantable collamer lens (TICL) for stable keratoconus after sequential procedure (corneal collagen crosslinking plus TICL implantation). Forty eyes of 24 patients with stable keratoconus with myopia between 0.00 and -18.00 dioptres (D) and astigmatism between 1.25 and 8.00 D were evaluated in this prospective interventional study (https://clinicaltrials.gov/ct2/show/NCT02833649). We evaluated refraction, visual outcomes, astigmatic changes analysed by Alpins vector, contrast sensitivity, aberrometry, modulation transfer functions (MTFs), defocus curve, and operative and postoperative complications. At 4-year follow-up, 45% had 20/20 vision or better and 100% had 20/40 or better uncorrected visual acuity (UCVA). Vector analysis of refractive astigmatism shows that the surgically induced astigmatism (SIA) (3.20±1.46 D) was not significantly different from the target induced astigmatism (TIA) (3.14±1.42 D) (p=0.620). At 4 years postoperatively, none of the eyes showed a decrease in UCVA, in contrast to 24 eyes in which UCVA was increased by ≥1 lines, with contrast sensitivity and improvement in total aberrations and MTF value at 5 per degree (*p=0.004) after TICL implantation. The cumulative 4-year corneal endothelial cell loss was ≤5%. No patients reported dissatisfaction. At the end of follow-up, the vault was 658±54.33m (range, 500-711) and the intraocular pressure was 11.7±2.08 mm Hg. Occurrences of glare and night-driving troubles diminished after TICL surgery. The results from this standardised clinical investigation support TICL implantation from clinical and optical viewpoints in patients with stable keratoconus. NCT02833649, Pre-results.

  4. Quality of life evaluation after implantation of 2 multifocal intraocular lens models and a monofocal model.

    Science.gov (United States)

    Alió, Jorge L; Plaza-Puche, Ana B; Piñero, David P; Amparo, Francisco; Rodríguez-Prats, Jose L; Ayala, María José

    2011-04-01

    To compare vision-related quality of life using the National Eye Institute Visual Function Questionnaire (NEI VFQ-25) in patients with 1 of 3 types of intraocular lenses (IOLs) and to correlate it with postoperative visual outcomes. Vissum Corporation-Instituto Oftalmológico de Alicante, Alicante, Spain. Comparative case series. This study comprised eyes having cataract surgery with bilateral implantation of a monofocal IOL (Group A), apodized multifocal IOL (Group B), or full diffractive multifocal IOL (Group C). Distance and near visual acuities, contrast sensitivity, and quality of life were evaluated preoperatively and postoperatively. The study enrolled 106 eyes (53 patients; age range 49 to 80 years). All groups had significant improvement in uncorrected and corrected distance visual acuities postoperatively (P ≤.05). Near vision outcomes were significantly better in Groups B and C (P ≤.01). Groups B and C had significantly less difficulty in some near tasks, such as reading the newspaper (A-B, P=.02; A-C, P=.02) or reading bills (A-B, P=.04; A-C, P=.004). Group C also had significantly less difficulty driving at night than Group B (P<.01). Near visual acuity and contrast sensitivity were significantly correlated with difficulty in near visual tasks in Groups B and C. Night-driving difficulty correlated significantly with contrast sensitivity in Group B. Patients with multifocal IOLs could perform several daily tasks at near and intermediate distances, with less night-driving limitation with the full diffractive IOL than with apodized multifocal and monofocal IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  5. Combined pars plana lensectomy-vitrectomy with open-loop flexible anterior chamber intraocular lens (AC IOL) implantation for subluxated lenses.

    Science.gov (United States)

    Kazemi, S; Wirostko, W J; Sinha, S; Mieler, W F; Koenig, S B; Sheth, B P

    2000-01-01

    To review our experience with combined pars plana lensectomy-vitrectomy and open-loop flexible anterior chamber intraocular lens (AC IOL) implantation for managing subluxated crystalline lenses. Retrospective review of 36 consecutive eyes (28 patients), all of which had subluxated crystalline lenses, managed by pars plana lensectomy-vitrectomy with insertion of an open-loop flexible AC IOL. The study was performed at the Medical College of Wisconsin, Milwaukee, over an 8-year period. An average preoperative visual acuity of 20/163 (range, 20/25 to hand motions) improved to 20/36 (range, 20/20 to 4/200) with surgery after a mean follow-up of 14 months (range, 1 to 59 months) (P IOL implantation appears to be an excellent technique for managing subluxated crystalline lenses. It is associated with a significant improvement in visual acuity (P subluxated lens through a limbal wound. Additionally, use of an AC IOL offers a simplified alternative to placement of a ciliary sulcus sutured posterior chamber intraocular lens (PC IOL).

  6. Molecular characterization and potential sources of aqueous humor bacterial contamination during phacoemulsification with intraocular lens implantation in dogs.

    Science.gov (United States)

    Lacerda, Luciana C C; de Souza-Pollo, Andressa; Padua, Ivan Ricardo M; Conceição, Luciano F; da Silveira, Camila P Balthazar; Silva, Germana A; Maluta, Renato P; Laus, José L

    2018-01-01

    Bacterial contamination of the anterior chamber during cataract surgery is one of the main responsible for endophthalmitis postoperative. Phacoemulsification is a less invasive technique for cataract treatment, although it does not exclude the possibility of contamination. In this study, bacterial contaminants of aqueous humor collected pre- and post-phacoemulsification with intraocular lens implantation (IOL) of twenty dogs were identified. As the conjunctival microbiota constitute a significant source of anterior chamber contamination, bacterial isolates from aqueous humor were genetically compared with those present in the conjunctival surface of the patients. Three dogs presented bacterial growth in both aqueous humor and conjunctival surface samples. Bacterial isolates from these samples were grouped according to their genetic profiles by repetitive-element PCR (rep-PCR) and their representatives were identified by 16S rRNA sequencing. Isolates from conjunctival surface were identified as Enterobacter spp., Staphylococcus spp. and S. aureus; and from aqueous humor samples as Enterobacter spp., Pantoea spp., Streptococcus spp. and Staphylococcus spp., respectively in decreasing order of prevalence. According to the rep-PCR analysis, 16.6% of Enterobacter spp. isolates from conjunctival surface were genetically similar to those from aqueous humor. The rest of isolates encountered in aqueous humor were genetically distinct from those of conjunctival surface. The significant genetic diversity of bacterial isolates found in the aqueous humor samples after surgery denoted the possibility of anterior chamber contamination during phacoemulsification by bacteria not only from conjunctival surface but also from different sources related to surgical environment. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Development and construction of a specific chamber for phototoxicity test

    Energy Technology Data Exchange (ETDEWEB)

    Sufi, Bianca S.; Mathor, Monica B., E-mail: biancasufi@usp.br, E-mail: mathor@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Esteves-Pedro, Natalia M.; Kaneko, Telma Mary, E-mail: nataliamenves@yahoo.com.br, E-mail: tsakuda@usp.br [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Fac. de Ciencias Farmaceuticas; Lopes, Patricia, E-mail: patricia.lopes@unifesp.br [Universidade Federal de Sao Paulo (UNIFESP), Diadema, SP (Brazil)

    2013-07-01

    Phototoxicity corresponds to the acute toxic response induced after skin exposure 'in vivo' and 'ex vivo' to certain chemicals and subsequent exposure to irradiation. Phototoxicity 'in vitro' assay is determined by viability of fibroblasts BALB/c 3T3 exposed to chemicals in the presence and absence of light. Substances identified as phototoxic are susceptible to 'in vivo' phototoxicity (OECD 432, 2004). A chamber was developed and constructed according to the guidelines OECD Toxicity Guide - 432 and ®ECVAM DB-ALM: INVITTOX N. 78. The chamber was built in stainless steel frame, with UVA lamps and dark area for negative control. The tests to qualify the chamber were performed with Sodium Lauryl Sulfate, recommended by the guides aforementioned, as negative control; and Bergamot oil (Givaudan-Roche), as positive control. Bergamot, Citrus bergamia, has, as major component, Bergapten responsible for its photosensitive activity. Both samples were diluted in Phosphate Buffered Saline with concentrations between 0.005 and 0.1 mg/mL, which were calculated by the dilution factor 1.47. These tests were performed over fibroblast BALB/c 3T3 culture and submitted to phototoxicity assay with MTS dye, under spectrophotometric reading, which allows determining the Photo Irritation Factor (PIF), what suggests that a substance with a PIF<2 predicts no phototoxicity; PIF>2 and <5 provides likely phototoxicity and PIF>5 provides phototoxicity. Sodium Lauryl Sulfate presented a PIF=1, being in accordance with the OECD. Bergamot oil has shown to be likely phototoxic with a PIF=2,475. These results provide that the chamber is qualified to be used to perform phototoxicity tests with assurance and security. (author)

  8. [Can the implantable collamer lens with AquaPORT technology safely prevent an angle block? Early experiences in the Homburg/Saar refractive surgery center].

    Science.gov (United States)

    Tsintarakis, T; Eppig, T; Langenbucher, A; Seitz, B; El-Husseiny, M

    2015-05-01

    The spectrum of surgical correction of high myopia has been broadened through surgical implantation of phakic intraocular lenses (pIOL) as a possible alternative to corneal refractive surgery. The purpose of the present study was to evaluate the intraoperative and early postoperative results of patients after the implantation of a posterior chamber implantable collamer (ICL) pIOL to correct high myopia. In particular the study tried to answer the question whether the AquaPORT technology can safely prevent angle closure glaucoma. From March 2012 to November 2013, 24 eyes from 12 patients suffering from a high myopia (-8.75 ± 4.37 D, maximum -22.75 D) underwent implantation of a posterior chamber implantable phakic collamer intraocular lens (ICL) with AquaPORT technology in the Homburg/Saar refractive surgery center. The implantable ICL consists of collamer, a collagen copolymer (Staar surgical-V4b/c). The mean age of the patients was 35.5 ± 1.35 years. At 12 months follow-up mean uncorrected distance visual acuity improved among the patients from 0.013 ± 0.04 preoperatively to 0.8 ± 0.45 postoperatively and the best corrected visual acuity from 0.8 ± 0.16 to 0.8 ± 0.3. Mean spherical equivalent decreased from -9.00 ± 4.68 D preoperatively to 0.12 ± 1.94 D postoperatively. A statistically significant difference in the intraocular pressure (IOP) was not observed (p = 0.3). The central distance between the posterior surface of the lens and the anterior surface of the pIOL (vault) was 0.45 ± 0.49 mm (minimum 0.064 mm, maximum 3.706 mm). Despite the AquaPORT a 28-year-old white woman suffered from a high postoperative IOP of 42 mmHg in both eyes and an ICL with diameter of 12.6 mm was substituted by an ICL with diameter 13.2 mm without complications. The implantation of an ICL with AquaPORT technology provides a reliable alternative with good postoperative visual quality to all patients with high myopia when corneal refractive surgery is not possible. In order

  9. Visual outcome and changes in corneal endothelial cell density following aphakic iris-fixated intraocular lens implantation in pediatric eyes with subluxated lenses.

    Science.gov (United States)

    Siddiqui, Sorath Noorani; Khan, Ayesha

    2013-01-01

    To evaluate the visual outcome and corneal endothelial cell density after Artisan aphakic intraocular lens (IOL) implantation (Ophtec, Groningen, the Netherlands) in pediatric eyes with subluxated lenses. Artisan aphakic IOLs were implanted in 18 eyes of 11 children with subluxated lenses. Idiopathic subluxations and ectopia lentis due to Marfan syndrome were included, whereas subluxations due to trauma or buphthalmos were excluded. Best-corrected visual acuity (BCVA) and endothelial cell density were monitored. Mean postoperative BCVA and endothelial cell density at last follow-up visit were calculated. The age of children at the time of Artisan aphakic IOL implantation ranged from 8 to 16 years (mean: 11.58 ± 2.9 years). Mean follow-up was 9.12 ± 4.30 months. Mean postoperative logarithm of the minimum angle of resolution BCVA was 0.26 ± 0.13 (P = .001) and mean postoperative endothelial cell density was 2,860 ± 435 cells/mm(2) (P = .000). Mean endothelial cell loss was 17.1%. Artisan aphakic IOL implantation is a safe surgical choice in the management of ectopia lentis in the pediatric age group. It has minimal complications and is less traumatic to pediatric eyes. However, long-term follow-up of these children is required.[J Pediatr Ophthalmol Strabismus 2013;50(3):178-182.]. Copyright 2013, SLACK Incorporated.

  10. The effectiveness of early lens extraction with intraocular lens implantation for the treatment of primary angle-closure glaucoma (EAGLE: study protocol for a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Chew Paul

    2011-05-01

    Full Text Available Abstract Background Glaucoma is the leading cause of irreversible blindness. Although primary open-angle glaucoma is more common, primary angle-closure glaucoma (PACG is more likely to result in irreversible blindness. By 2020, 5·3 million people worldwide will be blind because of PACG. The current standard care for PACG is a stepped approach of a combination of laser iridotomy surgery (to open the drainage angle and medical treatment (to reduce intraocular pressure. If these treatments fail, glaucoma surgery (eg, trabeculectomy is indicated. It has been proposed that, because the lens of the eye plays a major role in the mechanisms leading to PACG, early clear lens extraction will improve glaucoma control by opening the drainage angle. This procedure might reduce the need for drugs and glaucoma surgery, maintain good visual acuity, and improve quality of life compared with standard care. EAGLE aims to evaluate whether early lens extraction improves patient-reported, clinical outcomes, and cost-effectiveness, compared with standard care. Methods/Design EAGLE is a multicentre pragmatic randomized trial. All people presenting to the recruitment centres in the UK and east Asia with newly diagnosed PACG and who are at least 50 years old are eligible. The primary outcomes are EQ-5D, intraocular pressure, and incremental cost per quality adjusted life year (QALY gained. Other outcomes are: vision and glaucoma-specific patient-reported outcomes, visual acuity, visual field, angle closure, number of medications, additional surgery (e.g., trabeculectomy, costs to the health services and patients, and adverse events. A single main analysis will be done at the end of the trial, after three years of follow-up. The analysis will be based on all participants as randomized (intention to treat. 400 participants (200 in each group will be recruited, to have 90% power at 5% significance level to detect a difference in EQ-5D score between the two groups of 0·05

  11. Fuchs Heterochromic Iridocylitis: Clinical Characteristics and Outcome of Cataract Extraction with Intra Ocular Lens Implantation in a Kashmiri Population- A Hospital Based Study

    Science.gov (United States)

    Lone, Imtiyaz; Mir, Adil Majid; Rashid, Aamir; Latif, Mehreen

    2016-01-01

    Introduction Fuchs Heterochromic Iridocylitis (FHI) is a rare form of uveitis which is frequently complicated by cataract and glaucoma, but it does not show typical features of uveitis like pain, redness and posterior synechia. Aim To study the clinical characteristics and outcome of cataract extraction with Intra Ocular Lens (IOL) implantation in patients with FHI. Materials and Methods The present prospective study was carried out in the Postgraduate Department of Ophthalmology, Sher-i-Kashmir Institute of Medical Sciences (SKIMS), Bemina from March 2012 to January 2015. The study included 33 eyes of 32 patients of FHI who underwent thorough clinical examination and cataract surgery with IOL implantation and were evaluated based on their visual outcome and intra and post-operative complications. Post-operative follow-up was done on 1st day, one week, one month, two month, six month and at twelve months. Results Mean age of our study group was 33.9 years (Range 18 to 65 years). No male or female preponderance was seen. There was bilateral involvement of eyes in only one case. Cataract and stellate keratic precipitates were present in all cases whereas, heterochromia was present in only six eyes (18.75%). Best Corrected Visual Acuity (BCVA) showed a significant improvement following cataract surgery (p 6/12). Most common causes of decreased vision post-operatively were vitreous opacities in nine eyes (27.27%) followed by glaucoma in eight eyes (24.24%) and posterior capsular opacification in six eyes (18.18%). Conclusion Cataract extraction with IOL lens implantation in FHI is a safe procedure associated with good visual prognosis and few complications. However, glaucoma is one of the main concerns and should be closely monitored both pre and post-operatively. PMID:28208900

  12. Phototoxicity in an ultraviolet ink manufacturing plant.

    Science.gov (United States)

    Linnell, Joshua D; Amani-Taleshi, Darius; Korentager, Richard; Dougherty, William R

    2012-01-01

    Ultraviolet (UV) dyes are used as inks in garment printing. Hypersensitivity reactions to these compounds have been reported in the literature. The authors report a case of reaction to UV ink in a patient already on corticosteroid therapy. The patient's clinical course was reviewed along with images of wounds that subsequently developed. The affected areas were debrided and covered with Vaseline gauze and silver impregnated dressings. Epithelium was salvaged in many areas, and regrowth occurred over several weeks in regions of deeper injury. The concurrent use of steroids and the rapidity of the onset of symptoms were not characteristic of hypersensitivity dermatitis, which has previously been reported. The cause of the wounds was likely phototoxicity from radical subtypes in the ink that catalyze the reaction when exposed to UV light.

  13. Bilateral implantation of +2.5 D multifocal intraocular lens and contralateral implantation of +2.5 D and +3.0 D multifocal intraocular lenses: Clinical outcomes

    NARCIS (Netherlands)

    Nuijts, Rudy M. M. A.; Jonker, Soraya M. R.; Kaufer, Robert A.; Lapid-Gortzak, Ruth; Mendicute, Javier; Martinez, Cristina Peris; Schmickler, Stefanie; Kohnen, Thomas

    2016-01-01

    To assess the clinical visual outcomes of bilateral implantation of Restor +2.5 diopter (D) multifocal intraocular lenses (IOLs) and contralateral implantation of a Restor +2.5 D multifocal IOL in the dominant eye and Restor +3.0 D multifocal IOL in the fellow eye. Multicenter study at 8

  14. Phototoxic potential of silymarin and its bioactive components

    Czech Academy of Sciences Publication Activity Database

    Svobodová-Rajnochová, A.; Zálešák, B.; Biedermann, David; Ulrichová, J.; Vostálová, J.

    2016-01-01

    Roč. 156, MAR 2016 (2016), s. 61-68 ISSN 1011-1344 Institutional support: RVO:61388971 Keywords : Flavonolignans * Phototoxicity * 313 NRU Subject RIV: CE - Biochemistry Impact factor: 2.673, year: 2016

  15. Phototoxicity: Its Mechanism and Animal Alternative Test Methods

    Science.gov (United States)

    Park, Hyeonji; Lim, Kyung-Min

    2015-01-01

    The skin exposure to solar irradiation and photoreactive xenobiotics may produce abnormal skin reaction, phototoxicity. Phototoxicity is an acute light-induced response, which occurs when photoreacive chemicals are activated by solar lights and transformed into products cytotoxic against the skin cells. Multifarious symptoms of phototoxicity are identified, skin irritation, erythema, pruritis, and edema that are similar to those of the exaggerated sunburn. Diverse organic chemicals, especially drugs, are known to induce phototoxicity, which is probably from the common possession of UV-absorbing benzene or heterocyclic rings in their molecular structures. Both UVB (290~320 nm) and UVA (320~400 nm) are responsible for the manifestation of phototoxicity. Absorption of photons and absorbed energy (hv) by photoactive chemicals results in molecular changes or generates reactive oxygen species and depending on the way how endogenous molecules are affected by phototoxicants, mechanisms of phototoxcity is categorized into two modes of action: Direct when unstable species from excited state directly react with the endogenous molecules, and indirect when endogeneous molecules react with secondary photoproducts. In order to identify phototoxic potential of a chemical, various test methods have been introduced. Focus is given to animal alternative test methods, i.e., in vitro, and in chemico assays as well as in vivo. 3T3 neutral red uptake assay, erythrocyte photohemolysis test, and phototoxicity test using human 3-dimensional (3D) epidermis model are examples of in vitro assays. In chemico methods evaluate the generation of reactive oxygen species or DNA strand break activity employing plasmid for chemicals, or drugs with phototoxic potential. PMID:26191378

  16. Development and construction of a specific chamber for phototoxicity test

    International Nuclear Information System (INIS)

    Sufi, Bianca S.; Mathor, Monica B.; Esteves-Pedro, Natalia M.; Kaneko, Telma Mary

    2013-01-01

    Phototoxicity corresponds to the acute toxic response induced after skin exposure 'in vivo' and 'ex vivo' to certain chemicals and subsequent exposure to irradiation. Phototoxicity 'in vitro' assay is determined by viability of fibroblasts BALB/c 3T3 exposed to chemicals in the presence and absence of light. Substances identified as phototoxic are susceptible to 'in vivo' phototoxicity (OECD 432, 2004). A chamber was developed and constructed according to the guidelines OECD Toxicity Guide - 432 and ®ECVAM DB-ALM: INVITTOX N. 78. The chamber was built in stainless steel frame, with UVA lamps and dark area for negative control. The tests to qualify the chamber were performed with Sodium Lauryl Sulfate, recommended by the guides aforementioned, as negative control; and Bergamot oil (Givaudan-Roche), as positive control. Bergamot, Citrus bergamia, has, as major component, Bergapten responsible for its photosensitive activity. Both samples were diluted in Phosphate Buffered Saline with concentrations between 0.005 and 0.1 mg/mL, which were calculated by the dilution factor 1.47. These tests were performed over fibroblast BALB/c 3T3 culture and submitted to phototoxicity assay with MTS dye, under spectrophotometric reading, which allows determining the Photo Irritation Factor (PIF), what suggests that a substance with a PIF 2 and 5 provides phototoxicity. Sodium Lauryl Sulfate presented a PIF=1, being in accordance with the OECD. Bergamot oil has shown to be likely phototoxic with a PIF=2,475. These results provide that the chamber is qualified to be used to perform phototoxicity tests with assurance and security. (author)

  17. Corneal Collagen Cross-Linking Combined with an Artiflex Iris-Fixated Anterior Chamber Phakic Intraocular Lens Implantation in a Patient with Progressive Keratoconus

    Directory of Open Access Journals (Sweden)

    Sharif Hashmani

    2017-10-01

    Full Text Available We present here the case of a 24-year-old male who experienced progressive keratoconus and vision loss which adversely affected his ability to carry out everyday tasks. This landed him in the Hashmanis Hospital for consultation. He had a preoperative best corrected visual acuity of 6/12. He underwent multiple Oculus Pentacam examinations, which showed progressive keratoconus. Corneal collagen cross-linking (CXL was performed to stabilize his cornea and, subsequently, an Artiflex anterior chamber iris-fixated phakic intraocular lens (ACIF-PIOL was implanted to alleviate his refractive errors. The patient achieved a postoperative uncorrected visual acuity of 6/12. This report shows that CXL combined with ACIF-PIOL can be safe and effective in those with progressive keratoconus.

  18. Implantation of a Multifocal Toric Intraocular Lens after Radial Keratotomy and Cross-Linking with Hyperopia and Astigmatism Residues: A Case Report

    Directory of Open Access Journals (Sweden)

    Raffaele Nuzzi

    2017-08-01

    Full Text Available Radial keratotomy is a refractive surgical technique, widely used in the 80s and early 90s to correct myopia and astigmatism, but now overcome by more recent laser techniques. Important consequences, often in patients with more than 45 years of age, are progressive hyperopic shift and/or an increase in corneal astigmatism, whose main cause seems to be an increase in the curvature radius of the central portion of the cornea. This seems to be due to radial keratotomy incisions – with the consequent need for cross-linking – intraocular pressure, and corneal biomechanical parameters. The authors propose phacoemulsification with a customized multifocal toric intraocular lens implantation to correct the induced shift and hyperopic astigmatism. A decent postoperative visual acuity was observed with good patient satisfaction. A specific protocol must be applied to optimize the correct diagnosis, presurgical evaluation and postsurgical outcomes that are to be maintained over time, without regressions.

  19. Bilateral implantation of +2.5 D multifocal intraocular lens and contralateral implantation of +2.5 D and +3.0 D multifocal intraocular lenses: Clinical outcomes.

    Science.gov (United States)

    Nuijts, Rudy M M A; Jonker, Soraya M R; Kaufer, Robert A; Lapid-Gortzak, Ruth; Mendicute, Javier; Martinez, Cristina Peris; Schmickler, Stefanie; Kohnen, Thomas

    2016-02-01

    To assess the clinical visual outcomes of bilateral implantation of Restor +2.5 diopter (D) multifocal intraocular lenses (IOLs) and contralateral implantation of a Restor +2.5 D multifocal IOL in the dominant eye and Restor +3.0 D multifocal IOL in the fellow eye. Multicenter study at 8 investigative sites. Prospective randomized parallel-group patient-masked 2-arm study. This study comprised adults requiring bilateral cataract extraction followed by multifocal IOL implantation. The primary endpoint was corrected intermediate visual acuity (CIVA) at 60 cm, and the secondary endpoint was corrected near visual acuity (CNVA) at 40 cm. Both endpoints were measured 3 months after implantation with a noninferiority margin of Δ = 0.1 logMAR. In total, 103 patients completed the study (53 bilateral, 50 contralateral). At 3 months, the mean CIVA at 60 cm was 0.13 logMAR and 0.10 logMAR in the bilateral group and contralateral group, respectively (difference 0.04 logMAR), achieving noninferiority. Noninferiority was not attained for CNVA at 40 cm; mean values at 3 months for bilateral and contralateral implantation were 0.26 logMAR and 0.11 logMAR, respectively (difference 0.15 logMAR). Binocular defocus curves suggested similar performance in distance vision between the 2 groups. Treatment-emergent ocular adverse events rates were similar between the groups. Bilateral implantation of the +2.5 D multifocal IOL resulted in similar distance as contralateral implantation of the +2.5 D multifocal IOL and +3.0 D multifocal IOL for intermediate vision (60 cm), while noninferiority was not achieved for near distances (40 cm). Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  20. Comparison of Visual, Refractive and Aberration Measurements of INTACS versus Toric ICL Lens Implantation; A Four-year Follow-up.

    Science.gov (United States)

    Ramin, Shahrokh; Sangin Abadi, Azad; Doroodgar, Farideh; Esmaeili, Mehrdad; Niazi, Faizollah; Niazi, Sana; Alinia, Cyrus; Golestani, Yaser; Taj Abadi, Reza

    2018-01-01

    This study was performed to evaluate the visual, refractive, and aberration measurement results of 2 implants, including Intacs Intracorneal Ring Segments (ICRS) and phakic Toric Implantable Collamer Lens (TICL), in patients with moderate Keratoconus (KCN). In this retrospective cross-sectional study, 30 patients with KCN with a mean age of 29.83 years were included in 2 groups, including the Intacs Intracorneal Ring Segments (ICRS) group and the phakic Toric Implantable Collamer Lens (TICL) group. Preoperative data as well as 6-month, 1-, 2-, 3- and 4-year follow-up data after the operation were collected and analyzed with the SPSS software (ver. 23.0, SPSS, Inc., Chicago, IL), using the paired t-test, independent t-test, repeated measures Analysis of Variance (ANOVA), and one-way ANOVA. This study included 30 patients with KCN with a mean age of 29.83 years and range of 25 to 35 years, including 17 males with a mean age of 30.11 years and 13 female with a mean age of 29.25 years. Except for preoperative Uncorrected Distance Visual Acuity (UCDVA), Spherical Equivalent (SE) and astigmatism, there was a significant difference between the 2 groups regarding other variables. The TICL group had a significantly better UCDVA and Best Corrected Distance Visual Acuity (BCDVA) in all post-operative follow-ups, and SE and astigmatism values were significantly lower in all post-operative follow-ups when compared with the ICRS group. There was a significant reduction in corneal and total coma as well as internal trefoil aberrations (P<0.01, P<0.01, and P=0.014, respectively) in the ICRS group, and TICL led to a significant reduction in internal trefoil aberration with P<0.03. Comparison of the 2 groups revealed a significant difference in corneal spherical (P<0.01) and total coma (P=0.02) aberrations and no significant differences in other HOA. Both ICRS and TICL are useful in patients with moderate KCN. However, TICL appears to have more stable and predictable vision results.

  1. Phototoxicity activity of Psoralea drupacea L. using Atremia salina bioassay system

    Directory of Open Access Journals (Sweden)

    Mohammad Ramezani

    2011-07-01

    Conclusion: The result showed that P. drupacea methanolic extract and chloroform fraction have phototoxicity in A. salina bioassay system and their toxic effect is related to phototoxic constituents such as psoralen.

  2. Clinical and patient-reported outcomes of bilateral implantation of a +2.5 diopter multifocal intraocular lens.

    Science.gov (United States)

    Maxwell, Andrew; Holland, Edward; Cibik, Lisa; Fakadej, Anna; Foster, Gary; Grosinger, Les; Moyes, Andrew; Nielsen, Stephen; Silverstein, Steven; Toyos, Melissa; Weinstein, Arthur; Hartzell, Scott

    2017-01-01

    To assess the effectiveness and safety of a multifocal intraocular lens (IOL) with +2.5 diopter (D) additional power compared with a monofocal IOL. Fifteen sites in the United States. Prospective randomized patient- and observer-masked clinical trial. Randomized patients received multifocal or monofocal IOLs bilaterally. Visual acuity (33 cm, 40 cm, 53 cm, 60 cm, 4 m) was measured; safety was assessed through adverse event rates. Patient-reported visual outcomes were evaluated using the Visual Tasks questionnaire. The frequency and severity of visual disturbances were evaluated using the Assessment of Photic Phenomena and Lens EffectS questionnaire. The multifocal IOL (n = 155) provided better corrected distance visual acuity at 53 cm than the monofocal IOL (n = 165) (0.322 versus 0.512 logMAR; between-group difference, -0.190 logMAR; P < .0001) and 40 cm but not at 4 m. Ocular adverse event rates were less than 3.84% in both groups. Serious adverse event rates were comparable between the 2 IOL types. Patients with multifocal IOLs reported less difficulty with near tasks (with and without correction) and intermediate tasks (without correction). Difficulty with extended-intermediate and distance tasks was similar between groups. The most frequently reported self-rated severe phenomena were halos, starbursts, and glare. Most patients (monofocal ≥72%; multifocal ≥73%) reported never experiencing blurred, distorted, or double vision. The +2.5 D multifocal IOL provided better vision at 40 cm and 53 cm and similar vision at 4 m compared with the monofocal IOL. Safety profiles and visual phenomena were comparable between groups. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  3. Implantação de lente intraocular com uma alça amputada: proposta para o tratamento cirúrgico da subluxação do cristalino Intraocular lens implantation with one loop haptic amputed: a new propose to the subluxation lens surgical treatment

    Directory of Open Access Journals (Sweden)

    Marcelo Ventura

    2010-04-01

    Full Text Available OBJETIVO: Avaliar os resultados pós-operatórios da subluxação congênita do cristalino, corrigida por uma nova abordagem cirúrgica. MÉTODOS: Foram estudados 21 olhos de 13 pacientes, portadores de subluxação não traumática do cristalino submetidos à cirurgia na Fundação Altino Ventura, no período de abril de 1999 a abril de 2004. A idade média foi de 8,7 ± 5,4 anos, e o tempo médio de seguimento foi 21,5 ± 19,3 meses. Os pacientes foram submetidos à facoaspiração, implante do anel endocapsular e lente intraocular (LIO. Uma das alças da LIO foi amputada e apoiada sobre o anel, no interior do saco capsular, centralizando a LIO. RESULTADOS: Houve melhora da acuidade visual (AV em todos os casos, e redução significante do equivalente esférico e componente esférico comparando-se a refração pré e pós-operatória (pPURPOSE: To evaluate the postoperative results of congenital lens subluxation corrected by a new technique. METHODS: Retrospective chart review of 21 eyes of 13 patients with no traumatic lens subluxation who underwent surgery in Altino Ventura Foundation from April, 1999 to April, 2004. The mean age was 8.7 ± 5.4 years old, and the mean follow-up period was 21.5 ± 19.3 months. Patients underwent phacoaspiration, endocapsular ring and intraocular lens (IOL implantation. The implanted IOL had one loop haptic excised and was supported above the ring, inside the capsular bag promoting intraocular lens centralization. RESULTS: Visual acuity improvement was observed in all cases. There was a significant reduction of the spherical equivalent and spherical component comparing the pre and postoperative refraction (p<0.01. There was no statistically significant difference between the pre and postoperative cylinder component (p=0.71. Posterior capsule opacification was a postoperative complication found in 71.4% of the cases. Early posterior capsulotomy was performed with no complications in these cases. CONCLUSION

  4. Evaluation of a new electronic preoperative reference marker for toric intraocular lens implantation by two different methods of analysis: Adobe Photoshop versus iTrace.

    Science.gov (United States)

    Farooqui, Javed Hussain; Sharma, Mansi; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2017-01-01

    The aim of this study is to compare two different methods of analysis of preoperative reference marking for toric intraocular lens (IOL) after marking with an electronic marker. Cataract and IOL Implantation Service, Shroff Eye Centre, New Delhi, India. Fifty-two eyes of thirty patients planned for toric IOL implantation were included in the study. All patients had preoperative marking performed with an electronic preoperative two-step toric IOL reference marker (ASICO AE-2929). Reference marks were placed at 3-and 9-o'clock positions. Marks were analyzed with two systems. First, slit-lamp photographs taken and analyzed using Adobe Photoshop (version 7.0). Second, Tracey iTrace Visual Function Analyzer (version 5.1.1) was used for capturing corneal topograph examination and position of marks noted. Amount of alignment error was calculated. Mean absolute rotation error was 2.38 ± 1.78° by Photoshop and 2.87 ± 2.03° by iTrace which was not statistically significant ( P = 0.215). Nearly 72.7% of eyes by Photoshop and 61.4% by iTrace had rotation error ≤3° ( P = 0.359); and 90.9% of eyes by Photoshop and 81.8% by iTrace had rotation error ≤5° ( P = 0.344). No significant difference in absolute amount of rotation between eyes when analyzed by either method. Difference in reference mark positions when analyzed by two systems suggests the presence of varying cyclotorsion at different points of time. Both analysis methods showed an approximately 3° of alignment error, which could contribute to 10% loss of astigmatic correction of toric IOL. This can be further compounded by intra-operative marking errors and final placement of IOL in the bag.

  5. Visual acuity and patient satisfaction at varied distances and lighting conditions after implantation of an aspheric diffractive multifocal one-piece intraocular lens.

    Science.gov (United States)

    Chang, Daniel H

    2016-01-01

    The aim of the study is to evaluate the visual acuity and patient satisfaction at varied distances under photopic and mesopic lighting conditions in patients bilaterally implanted with aspheric diffractive multifocal one-piece intraocular lenses. In this retrospective-prospective study, 16 patients with a mean age of 66.2±9.2 years (range: 50-81 years) who had undergone bilateral phacoemulsification surgery with implantation of a Tecnis multifocal one-piece intraocular lens (ZMB00) were evaluated. Monocular and binocular uncorrected and distance-corrected visual acuities were measured at distance (20 ft), intermediate (70-80 cm), and near (35-40 cm) under photopic (85 cd/m(2)) and mesopic (3 cd/m(2)) lighting conditions and were compared using the paired t-test. All patients also completed a subjective questionnaire. At a mean follow-up of 9.5±3.9 months, distance, near, and intermediate visual acuity improved significantly from preoperative acuity. Under photopic and mesopic conditions, 93.8% and 62.5% of patients, respectively, had binocular uncorrected intermediate visual acuity of 20/40 or better, and 62.5% and 31.3% of patients had binocular uncorrected near visual acuity of 20/20 or better. All patients were satisfied with their overall vision without using glasses and/or contact lenses when compared with before surgery. A total of 87.5% of patients reported no glare and 68.8% of patients reported no halos around lights at night. Tecnis multifocal one-piece intraocular lenses provide good distance, intermediate, and near visual acuity under photopic as well as mesopic lighting conditions. High levels of spectacle independence with low levels of photic phenomenon were achieved, resulting in excellent patient satisfaction.

  6. Phototoxicity of individual polycyclic aromatic hydrocarbons and petroleum to marine invertebrate larvae and juveniles

    International Nuclear Information System (INIS)

    Pelletier, M.C.; Burgess, R.M.; Ho, K.T.; Kuhn, A.; McKinney, R.A.; Ryba, S.A.

    1997-01-01

    Phototoxicity resulting from photoactivated polycyclic aromatic hydrocarbons (PAHs) has been reported in the literature for a variety of freshwater organisms. The magnitude of increase in PAH toxicity often exceeds a factor of 100. In the marine environment phototoxicity to marine organisms has not been reported for individual or complex mixtures of PAHs. In this study, larvae and juveniles of the bivalve, Mulinia lateralis, and juveniles of the mysid shrimp, Mysidopsis bahia, were exposed to individual known phototoxic PAHs (anthracene, fluoranthene, pyrene), as well as the water-accommodated fractions of several petroleum products (Fuel Oil number-sign 2, Arabian Light Crude, Prudhoe Bay Crude, Fuel Oil number-sign 6) containing PAHs. Phototoxicity of individual PAHs was 12 to >50,000 times that of conventional toxicity. Three of the petroleum products demonstrated phototoxicity while the lightest product, Fuel Oil number-sign 2, was not phototoxic at the concentrations tested. The phototoxicity of petroleum products appears to be dependent on the composition and concentrations of phototoxic PAHs present: lighter oils have fewer multiple aromatic ring, phototoxic compounds while heavier oils have higher levels of these types of molecules. This study shows that phototoxicity can occur in marine waters to marine species. Further, the occurrence of oil in marine waters presents the additional risk of phototoxicity not routinely assessed for during oil spills

  7. Protein Corona Prevents TiO2 Phototoxicity.

    Directory of Open Access Journals (Sweden)

    Maja Garvas

    Full Text Available TiO2 nanoparticles have generally low toxicity in the in vitro systems although some toxicity is expected to originate in the TiO2-associated photo-generated radical production, which can however be modulated by the radical trapping ability of the serum proteins. To explore the role of serum proteins in the phototoxicity of the TiO2 nanoparticles we measure viability of the exposed cells depending on the nanoparticle and serum protein concentrations.Fluorescence and spin trapping EPR spectroscopy reveal that the ratio between the nanoparticle and protein concentrations determines the amount of the nanoparticles' surface which is not covered by the serum proteins and is proportional to the amount of photo-induced radicals. Phototoxicity thus becomes substantial only at the protein concentration being too low to completely coat the nanotubes' surface.These results imply that TiO2 nanoparticles should be applied with ligands such as proteins when phototoxic effects are not desired - for example in cosmetics industry. On the other hand, the nanoparticles should be used in serum free medium or any other ligand free medium, when phototoxic effects are desired - as for efficient photodynamic cancer therapy.

  8. Facoemulsificação, vitrectomia via pars plana e implante de lente intra-ocular em olhos com retinopatia diabética proliferativa Phacoemulsification, pars plana vitrectomy and intraocular lens implant in eyes with proliferative diabetic retinopathy

    Directory of Open Access Journals (Sweden)

    Armando Belfort Mattos

    2004-06-01

    realizar a vitrectomia via pars plana, ao invés de se realizar uma segunda cirurgia, que seria somente para a remoção da catarata após a vitrectomia pars plana, é técnica segura e capaz de promover a melhora da acuidade visual além de ser menos agressiva para o paciente. O potencial para melhora da acuidade visual final é limitado pela gravidade da retinopatia diabética.PURPOSE: To evaluate the outcomes and the best technique for a combined phacoemulsification (PHACO, pars plana vitrectomy (PPV and posterior chamber intraocular lens insertion (PCIOL in one single procedure for patients with proliferative diabetic retinopathy. METHODS: We reviewed charts of 47 (53 eyes patients with proliferative diabetic retinopathy who underwent combined phacoemulsification with posterior chamber intraocular lens implant and pars plana vitrectomy performed between January 1991 and September 1998 at the Bascom Palmer Eye Institute, eye hospital affiliated with the University of Miami. The study was done in conjunction with the Federal University of São Paulo. A total of 43 eyes from 40 patients were elected to participate in the study. RESULTS: The follow-up range was three to 60 months (mean 20 months. The age ranged from 37 to 77 years with a mean of 59. Preoperative visual acuity improved two lines or more in 26 (60.4% eyes, remained the same in 9 (20.9% and got worse in 8 (18.6%. In 10 (23.2% eyes visual acuity improved to 20/40. The study showed to be statistically significant for the improvement of the final visual acuity. Recurrent vitreous hemorrhage was the most frequent postoperative complication found in 12 (27.9% eyes and it was followed by transient anterior chamber reaction in 9 (20.9% eyes. Intraoperative and postoperative complications related to phacoemulsification were rare. IOL capture was found in 2 (4.6% eyes and intraocular lens subluxation in 1 (2.3% eye. CONCLUSION: Combined phacoemulsification with posterior chamber intraocular lens implant and pars plana

  9. Review of titanium dioxide nanoparticle phototoxicity: Developing a phototoxicity ratio to correct the endpoint values of toxicity tests

    Science.gov (United States)

    2015-01-01

    Abstract Titanium dioxide nanoparticles are photoactive and produce reactive oxygen species under natural sunlight. Reactive oxygen species can be detrimental to many organisms, causing oxidative damage, cell injury, and death. Most studies investigating TiO2 nanoparticle toxicity did not consider photoactivation and performed tests either in dark conditions or under artificial lighting that did not simulate natural irradiation. The present study summarizes the literature and derives a phototoxicity ratio between the results of nano‐titanium dioxide (nano‐TiO2) experiments conducted in the absence of sunlight and those conducted under solar or simulated solar radiation (SSR) for aquatic species. Therefore, the phototoxicity ratio can be used to correct endpoints of the toxicity tests with nano‐TiO2 that were performed in absence of sunlight. Such corrections also may be important for regulators and risk assessors when reviewing previously published data. A significant difference was observed between the phototoxicity ratios of 2 distinct groups: aquatic species belonging to order Cladocera, and all other aquatic species. Order Cladocera appeared very sensitive and prone to nano‐TiO2 phototoxicity. On average nano‐TiO2 was 20 times more toxic to non‐Cladocera and 1867 times more toxic to Cladocera (median values 3.3 and 24.7, respectively) after illumination. Both median value and 75% quartile of the phototoxicity ratio are chosen as the most practical values for the correction of endpoints of nano‐TiO2 toxicity tests that were performed in dark conditions, or in the absence of sunlight. Environ Toxicol Chem 2015;34:1070–1077. © 2015 The Author. Published by SETAC. PMID:25640001

  10. Structure-activity relationships and prediction of the phototoxicity and phototoxic potential of new drugs.

    Science.gov (United States)

    Barratt, Martin D

    2004-11-01

    Relationships between the structure and properties of chemicals can be programmed into knowledge-based systems such as DEREK for Windows (DEREK is an acronym for "Deductive Estimation of Risk from Existing Knowledge"). The DEREK for Windows computer system contains a subset of over 60 rules describing chemical substructures (toxophores) responsible for skin sensitisation. As part of the European Phototox Project, the rule base was supplemented by a number of rules for the prospective identification of photoallergens, either by extension of the scope of existing rules or by the generation of new rules where a sound mechanistic rationale for the biological activity could be established. The scope of the rules for photoallergenicity was then further refined by assessment against a list of chemicals identified as photosensitisers by the Centro de Farmacovigilancia de la Comunidad Valenciana, Valencia, Spain. This paper contains an analysis of the mechanistic bases of activity for eight important groups of photoallergens and phototoxins, together with rules for the prospective identification of the photobiological activity of new or untested chemicals belonging to those classes. The mechanism of action of one additional chemical, nitrofurantoin, is well established; however, it was deemed inappropriate to write a rule on the basis of a single chemical structure.

  11. The 3T3 neutral red uptake phototoxicity test: Practical experience and implications for phototoxicity testing - The report of an ECVAM-EFPIA workshop

    NARCIS (Netherlands)

    Ceridono, M.; Tellner, P.; Bauer, D.; Barroso, J.; Alépée, N.; Corvi, R.; Smedt, A. de; Fellows, M.D.; Gibbs, N.K.; Heisler, E.; Jacobs, A.; Jirova, D.; Jones, D.; Kandárová,H.; Kasper, P.; Akunda, J.K.; Krul, C.; Learn, D.; Liebsch, M.; Lynch, A.M.; Muster, W.; Nakamura, K.; Nash, J.F.; Pfannenbecker, U.; Phillips, G.; Robles, C.; Rogiers, V.; Water, F. van de; Liminga, U.W.; Vohr, H.W.; Wattrelos, O.; Woods, J.; Zuang, V.; Kreysa, J.; Wilcox, P.

    2012-01-01

    This is the report from the “ECVAM–EFPIA workshop on 3T3 NRU Phototoxicity Test: Practical Experience and Implications for Phototoxicity Testing”, jointly organized by ECVAM and EFPIA and held on the 25–27 October 2010 in Somma Lombardo, Italy. The European Centre for the Validation of Alternative

  12. The Effects of Phacoemulsification and Intraocular Lens Implantation on Anatomical and Functional Parameters in Patients with Primary Angle Closure: A Prospective Study. (An American Ophthalmological Society Thesis).

    Science.gov (United States)

    Traverso, Carlo Enrico; Cutolo, Carlo Alberto

    2017-08-01

    To investigate the clinical, anatomical, and patient-reported outcomes of phacoemulsification (PE) with intraocular lens implantation performed to treat primary angle closure (PAC) and primary angle-closure glaucoma (PACG). Patients were evaluated at baseline and at 6 months after PE. The examination included visual acuity, intraocular pressure (IOP), visual field, optic nerve head, endothelial cell count (ECC), aqueous depth, and ocular biometric parameters. Patient-reported visual function and health status were assessed. Coprimary outcome measures were IOP changes, angle widening, and patient-reported visual function; secondary outcome measures were visual acuity changes, use of IOP-lowering medications, and complications. Univariate and multivariate analyses were performed to determine the predictors of IOP change. Thirty-nine cases were identified, and postoperative data were analyzed for 59 eyes, 39 with PACG and 20 with PAC. Globally, PE resulted in a mean reduction in IOP of -6.33 mm Hg (95% CI, -8.64 to -4.01, P <.001). Aqueous depth and angle measurements improved ( P <.01), whereas ECC significantly decreased ( P <.001). Both corrected and uncorrected visual acuity improved ( P <.01). The EQ visual analog scale did not change ( P =.16), but VFQ-25 improved ( P <.01). The IOP-lowering effect of PE was greater in the PACG compared to the PAC group ( P =.04). In both groups, preoperative IOP was the most significant predictor of IOP change ( P <.01). No sight-threatening complications were recorded. Our data support the usefulness of PE in lowering the IOP in patients with PAC and PACG. Although PE resulted in several anatomical and patient-reported visual improvements, we observe that a marked decrease in ECC should be carefully weighed before surgery.

  13. Phototoxic effects of 8-methoxypsoralen on rabbit corneal endothelium

    Energy Technology Data Exchange (ETDEWEB)

    Menon, I.A.; Basu, P.K.; Hasany, S.M.; Persad, S.D. (Univ. of Toronto, Ontario (Canada))

    1989-01-01

    The phototoxic effects of 8-methoxypsoralen (8-MOP) were investigated using the rabbit corneal endothelium in organ culture. The corneas were divided into four groups: (a) irradiated with a mercury vapor lamp (emitting UVA and visible radiation) in the presence of 8-MOP (experimental), (b) irradiated without 8-MOP (control A), (c) incubated with 8-MOP (control B) and (d) incubated without 8-MOP (control C). Specular and light microscopic examination showed that the experimental corneas had greater cellular damage compared to the control corneas. The effects of 8-MOP were restricted to certain localized areas of the cornea. However there was no significant difference in the amounts of 51Cr released from the labelled experimental and control corneas. These results show phototoxic damage of the corneal endothelial cells.

  14. MECHANISTIC STUDIES ON THE PHOTOTOXICITY OF ROSUVASTATIN, ITRACONAZOLE AND IMATINIB

    OpenAIRE

    Nardi, Giacomo

    2016-01-01

    Photosensitizing effects of xenobiotics are of increasing concern in public health since modern lifestyle often associates sunlight exposure with the presence of chemical substances in the skin. An important number of chemicals like perfumes, sunscreen components, or therapeutic agents have been reported as photosensitizers. In this context, a considerable effort has been made to design a model system for photosafety assessment. Indeed, screening for phototoxicity is necessary ...

  15. Avaliação da contaminação da câmara anterior na cirurgia de facoemulsificação com implante de lente intra-ocular Anterior chamber contamination in phacoemulsification surgery with intraocular lens implant

    Directory of Open Access Journals (Sweden)

    Cesar Nobuo Shiratori

    2002-06-01

    Full Text Available Objetivo: Avaliar a existência de contaminação da câmara anterior durante a facectomia por facoemulsificação com implante de lente intra-ocular. Método: Foi realizado estudo prospectivo, avaliando-se 30 pacientes submetidos a facectomia por facoemulsificação com implante de lente intra-ocular, colhendo-se duas amostras de humor aquoso, uma obtida no início e outra no final da cirurgia. As amostras foram semeadas em meio de cultura para germes aeróbios, anaeróbios e fungos. Resultado: Todas as amostras avaliadas resultaram negativas. Conclusão: A contaminação da câmara anterior na cirurgia de facoemulsificação com implante de lente intra-ocular, usando os cuidados necessários, é infreqüente.Purpose: To evaluate the frequency of anterior chamber contamination during phacoemulsification surgery with intraocular lens implant. Method: A prospective study was done with 30 patients submitted to phacoemulsification surgery with intraocular lens implant. Two samples of the aqueous humor were removed from the anterior chamber, one at the beginning and another one at the end of the surgery and were inoculated in culture plates for anaerobic and aerobic bacteria and fungi. Results: Intraocular aspirates yielded negative cultures. Conclusion: The absence of microorganisms in the samples evaluated allowed us to conclude that contamination during the phacoemulsification surgery with lens implant is unusual.

  16. Evaluation of the skin phototoxicity and photosensitivity of honeybee venom.

    Science.gov (United States)

    Han, Sang Mi; Hong, In Phyo; Woo, Soon Ok; Kim, Se Gun; Jang, He Rye; Park, Kwan Kyu

    2017-12-01

    Bee (Apis mellifera L.) venom (BV) has been used as a cosmetic ingredient owing to its anti-aging, anti-inflammatory, and antibacterial effects. The aim of this study was to assess the skin safety of BV. For this purpose, skin phototoxicity and sensitization tests were conducted in healthy male Hartley guinea pigs. The animals were divided into three groups (n=5) for the phototoxicity test: G1 (negative control), G2 (BV gel treatment), and G3 (positive control). After specified treatments, the animals were irradiated with ultraviolet A (15 J/cm 2 ). The photosensitivity test was also performed in three groups: G4 (negative control, n=5), G5 (BV gel treatment, n=10), and G6 (positive control, n=5). Erythema and edema were observed after 24, 48, and 72 hours in the positive control group, but not in the negative control and BV gel groups. Application of BV to the guinea pig skin had no toxic effects on any clinical signs, body weight, or mortality. In addition, it did not evoke a skin reaction in both either the skin phototoxicity and skin photosensitization tests. Therefore, it can be concluded that BV has the potential to be developed as a drug ingredient for topical uses. © 2017 The Authors. Journal of Cosmetic Dermatology Published by Wiley Periodicals, Inc.

  17. Combination of retinyl palmitate and UV-filters: phototoxic risk assessment based on photostability and in vitro and in vivo phototoxicity assays.

    Science.gov (United States)

    Benevenuto, Carolina Gomes; Guerra, Lucas Offenbecker; Gaspar, Lorena Rigo

    2015-02-20

    This study aimed to assess the phototoxic potential of combined UV-filters and retinyl palmitate (RP) in the presence or not of bemotrizinol (BMTZ), employing photostability and in vitro and in vivo phototoxicity assays. The formulations tested contained octocrylene (OCT), octyl methoxycinnamate (OMC), benzophenone-3 (BZP-3) and RP (photostable) or octocrylene (OCT), octyl methoxycinnamate (OMC), avobenzone (AVO) and RP (less photostable). Both formulations were supplemented with bemotrizinol. Photostability was evaluated by exposing, or not, formulations spread on a glass plate to UVA/UVB irradiation. The resulting products were quantified by HPLC analysis. In vitro phototoxicity of UV-filters and combinations were evaluated using 3T3 viable monolayer fibroblast cultures submitted, or not, to irradiation according to OECD TG 432. In vivo photoallergy and photoxicity were assessed by clinical studies (photopatch test). Photostability assays showed that UV-filter bemotrizinol was a better photostabilizer for RP/benzophenone-3 than for RP/avobenzone. The in vitro phototoxicity of the combination RP/avobenzone was reduced by bemotrizinol. Clinical studies did not indicate phototoxic or photoallergenic potentials in all formulations tested. It is concluded that the 3T3 NRU phototoxicity test may be considered a supplementary assay in formulation developments, since it can detect chemically unstable and potentially phototoxic combinations. However, extrapolation of in vitro positive results to human photopatch tests may be performed only to a limited extent. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Power prediction for one-piece and three-piece intraocular lens implantation after cataract surgery in patients with chronic angle-closure glaucoma: a prospective, randomized clinical trial.

    Science.gov (United States)

    Rhiu, Soolienah; Lee, Eun Suk; Kim, Tae-im; Lee, Hye Sun; Kim, Chan Yun

    2012-12-01

    To assess the accuracy of intraocular lens (IOL) power prediction for cataract surgery in chronic angle-closure glaucoma (CACG) patients with different IOLs' implantation. This prospective randomized clinical trial included 45 eyes with CACG and 48 eyes with normal controls undergoing cataract surgery. In the CACG group, 23 eyes (51%) had three-piece IOL implantation and 22 eyes (49%) had one-piece IOL implantation. In the normal control group, 25 eyes (52%) had three-piece IOL implantation and 23 eyes (48%) had one-piece IOL implantation. Using the SRK/T formula, the mean difference between the predicted and actual postoperative spherical equivalent [mean absolute error (MAE)] was obtained and converted to natural logarithm (ln) for statistical analysis. The power of the implanted IOL was calculated to predict postoperative SE using three formulas: SRK II, Holladay II and Hoffer Q by post hoc analysis in each group. The predictive accuracy of each formula was analysed by comparing the lnMAE. In the one-piece IOL group, there was no difference in lnMAE between the CACG and normal control group (p = 0.314). In the three-piece IOL group, the lnMAE of the CACG group was larger than that of the normal control group (p one-piece IOL group. Implantation of one-piece IOLs provides similar power prediction accuracy comparable to normal cataract patients; this result may be explained by the IOL haptic configuration or design. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.

  19. Objective lens

    Science.gov (United States)

    Olczak, Eugene G. (Inventor)

    2011-01-01

    An objective lens and a method for using same. The objective lens has a first end, a second end, and a plurality of optical elements. The optical elements are positioned between the first end and the second end and are at least substantially symmetric about a plane centered between the first end and the second end.

  20. In vitro/in vivo phototoxic risk assessments of griseofulvin based on photobiochemical and pharmacokinetic behaviors.

    Science.gov (United States)

    Seto, Yoshiki; Onoue, Satomi; Yamada, Shizuo

    2009-09-10

    The present investigation aims to establish efficacious screening strategy to clarify the phototoxic potential of pharmaceutical substances and its possible pathways by characterizing both photobiochemical properties and pharmacokinetic profiles. Photochemical behavior of griseofulvin, as model compounds, was evaluated by reactive oxygen species (ROS) assay, and the photogenotoxic potential was also assessed by DNA binding assay, DNA photocleavage assay, and atomic force microscopy. Pharmacokinetic (PK) study was also carried out after dermal and oral administration of griseofulvin in rats. ROS assay suggested the phototoxic potential of griseofulvin via type II photochemical pathways, and the photogenotoxic risk of griseofulvin was also proposed as evidenced by high affinity toward DNA and potent DNA photocleaving activity. PK profiling and in vivo phototoxicity testing demonstrated that a highly concentrated griseofulvin in the skin might cause phototoxic skin reactions in rats, whereas oral administration of griseofulvin in single dosing regimen (20mg/kg) resulted in 10(3)-fold less skin deposition than phototoxic skin concentration of griseofulvin. Upon these findings, the phototoxic potential of griseofulvin might not be severe at least in a single oral dosing regimen, whereas it might be phototoxic in dermal administration. The combination use of photobiochemical and pharmacokinetic data would be valuable to provide reliable prediction on phototoxic risk and possible toxic pathways of new drug entities in the early stage of drug discovery.

  1. Observations on the relationship between the levels of serum IL-6 and TNF-α and the severity of diabetic retinopathy and curative effect in cataract extraction with intraocular lens implantation in diabetics

    International Nuclear Information System (INIS)

    Wang Yumin; Ma Xinying; Song Yuebing; Liang Yong; Zhang Xiaoguang

    2001-01-01

    Objective: To determine the sequential changes of blood levels of interleukin-6 (IL-6) and tumor necrosis factor-α (TNF-α) in diabetics with extracapsular extraction and posterior chamber intraocular lens implantation and to study their correlation with curative effects and pos-operative complications. Methods: The serum concentrations of IL-6 and TNF-α in 39 diabetics and non-diabetics were measured by radioimmunoassay at preoperative, post-operative and on days 7, 14 and 90 postoperatively. Results: There was significant difference in the levels of the two factors between the diabetic group and non-diabetic group preoperatively (P<0.05). The serum levels of the two factors in patients with proliferative diabetic retinopathy were higher than those in non-diabetic retinopathy, and simple diabetic retinopathy post-operative (P<0.01). Post-operative complication rate was higher in patients with proliferative diabetic retinopathy than those without retinopathy and those having simple diabetic retinopathy. Conclusion: The levels of the two factors correlate with complications and curative effect of patients with proliferative diabetic retinopathy undergoing intraocular lens implantation

  2. Primary anterior chamber intraocular lens for the treatment of severe crystalline lens subluxation.

    Science.gov (United States)

    Hoffman, Richard S; Fine, I Howard; Packer, Mark

    2009-10-01

    Subluxated cataractous and clear lenses are commonly treated by limbal or pars plana lensectomy followed by primary or secondary intraocular lens (IOL) implantation. Adjunctive capsular prosthetic devices have facilitated lens removal and IOL centration in these challenging cases but have also added complexity and potential complications to the procedure. Although crystalline lens extraction may be required to clear the visual axis in mild to moderate lens subluxations, we propose insertion of a primary anterior chamber IOL without lens extraction in severe subluxations when the eye is optically aphakic or can be made functionally aphakic following neodymium:YAG laser zonulysis. Two cases demonstrating this approach are presented.

  3. Phototoxicity Evaluation of Pharmaceutical Substances with a Reactive Oxygen Species Assay Using Ultraviolet A

    Science.gov (United States)

    Lee, Yong Sun; Yi, Jung-Sun; Lim, Hye Rim; Kim, Tae Sung; Ahn, Il Young; Ko, Kyungyuk; Kim, JooHwan; Park, Hye-Kyung; Sohn, Soo Jung; Lee, Jong Kwon

    2017-01-01

    With ultraviolet and visible light exposure, some pharmaceutical substances applied systemically or topically may cause phototoxic skin irritation. The major factor in phototoxicity is the generation of reactive oxygen species (ROS) such as singlet oxygen and superoxide anion that cause oxidative damage to DNA, lipids and proteins. Thus, measuring the generation of ROS can predict the phototoxic potential of a given substance indirectly. For this reason, a standard ROS assay (ROS assay) was developed and validated and provides an alternative method for phototoxicity evaluation. However, negative substances are over-predicted by the assay. Except for ultraviolet A (UVA), other UV ranges are not a major factor in causing phototoxicity and may lead to incorrect labeling of some non-phototoxic substances as being phototoxic in the ROS assay when using a solar simulator. A UVA stimulator is also widely used to evaluate phototoxicity in various test substances. Consequently, we identified the applicability of a UVA simulator to the ROS assay for photoreactivity. In this study, we tested 60 pharmaceutical substances including 50 phototoxins and 10 non-phototoxins to predict their phototoxic potential via the ROS assay with a UVA simulator. Following the ROS protocol, all test substances were dissolved in dimethyl sulfoxide or sodium phosphate buffer. The final concentration of the test solutions in the reaction mixture was 20 to 200 μM. The exposure was with 2.0~2.2 mW/cm2 irradiance and optimization for a relevant dose of UVA was performed. The generation of ROS was compared before and after UVA exposure and was measured by a microplate spectrophotometer. Sensitivity and specificity values were 85.7% and 100.0% respectively, and the accuracy was 88.1%. From this analysis, the ROS assay with a UVA simulator is suitable for testing the photoreactivity and estimating the phototoxic potential of various test pharmaceutical substances. PMID:28133512

  4. Chronic phototoxic maculopathy caused by welding arc in occupational welders.

    Science.gov (United States)

    Yang, Xiaoran; Shao, Dongping; Ding, Xiaohu; Liang, Xuefen; Yang, Jiehua; Li, Jie

    2012-02-01

    To investigate whether occupationally-related phototoxicity can occur from welding. Cross-sectional study. Forty welders from manufacturing enterprise and 40 age-matched nonwelder controls. Participants underwent thorough ophthalmologic examination including fundus photography, automatic perimeter examination, and high definition optical coherence tomography (OCT) scan. The clinical history of all subjects was screened carefully before the study. There was no significant difference for best corrected distance visual acuity when comparing welders with nonwelders. Anterior segment, red reflex, Amsler grid test, and perimetric examinations were unremarkable. Fundus photographs revealed a small, round, or oval, dark-yellow macular lesion with an obscure boundary in 19 welder eyes (23.8%). OCT revealed an interruption or defect in the inner segment/outer segment (IS/OS) layer and the inner portion retinal pigment epithelium (RPE) layer in varying degrees in 30 welder eyes (38.0%), revealing a higher prevalence of maculopathy. All control examinations were unremarkable. We have also discovered that OCT is more sensitive than fundus photography in identifying macular lesions. Occupational welders exposed to a welding arc environment have a higher risk of phototoxic maculopathy than nonwelders, as diagnosed most effectively using OCT. Copyright © 2012 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  5. A bioassay using Artemia salina for detecting phototoxicity of plant coumarins.

    Science.gov (United States)

    Ojala, T; Vuorela, P; Kiviranta, J; Vuorela, H; Hiltunen, R

    1999-12-01

    Artemia salina (brine shrimp) has been successfully used for toxicity testing, and a screening test for phototoxicity has been developed based on this method. The ability of the method to test the phototoxic potential of seven known compounds was investigated. Athamantin (an angular furanocoumarin) and umbelliferone (a simple coumarin) showed no phototoxicity, while linear furanocoumarins exhibited phototoxic activity in the following order: psoralen > bergapten > peucedanin > xanthotoxin. The applicability of this method was also tested in screening the phototoxicity of plant material. Six plants from Apiaceae [Aegopodium podagraria L., Anethum graveolens L., Angelica archangelica L., Levisticum officinalis Koch, Petroselinum crispum (P. Mill) A. W. Hill., and Peucedanum palustre (L.) Moench] and one from Rutaceae (Ruta graveolens L.) were selected, all of them known to contain furanocoumarins. Extracts from leaves collected at different times during the growth period were used in the screening. Our results were in accordance with the furanocoumarin content of these plants and with the results of other phototoxicity tests. The Artemia salina method proved to be rapid, simple and inexpensive, and is therefore ideal in the initial biological screening of large numbers of samples for simultaneous detection of both toxicity and phototoxicity.

  6. Reliable Screening of Dye Phototoxicity by Using a Caenorhabditis elegans Fast Bioassay.

    Directory of Open Access Journals (Sweden)

    Javier Ignacio Bianchi

    Full Text Available Phototoxicity consists in the capability of certain innocuous molecules to become toxic when subjected to suitable illumination. In order to discover new photoactive drugs or characterize phototoxic pollutants, it would be advantageous to use simple biological tests of phototoxicy. In this work, we present a pilot screening of 37 dyes to test for phototoxic effects in the roundworm Caenorhabditis elegans. Populations of this nematode were treated with different dyes, and subsequently exposed to 30 min of white light. Behavioral outcomes were quantified by recording the global motility using an infrared tracking device (WMicrotracker. Of the tested compounds, 17 dyes were classified as photoactive, being phloxine B, primuline, eosin Y, acridine orange and rose Bengal the most phototoxic. To assess photoactivity after uptake, compounds were retested after washing them out of the medium before light irradiation. Dye uptake into the worms was also analyzed by staining or fluorescence. All the positive drugs were incorporated by animals and produced phototoxic effects after washing. We also tested the stress response being triggered by the treatments through reporter strains. Endoplasmic reticulum stress response (hsp-4::GFP strain was activated by 22% of phototoxic dyes, and mitochondrial stress response (hsp-6::GFP strain was induced by 16% of phototoxic dyes. These results point to a phototoxic perturbation of the protein functionality and an oxidative stress similar to that reported in cell cultures. Our work shows for the first time the feasibility of C. elegans for running phototoxic screenings and underscores its application on photoactive drugs and environmental pollutants assessment.

  7. Contaminação bacteriana da câmara anterior pós-facoemulsificação com implante de lente intra-ocular de polimetilmetacrilato ou silicone Bacterial anterior chamber contamination after phacoemulsification and polymethylmethacrylate or silicone intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Ricardo Antonio Pereira

    2004-12-01

    Full Text Available OBJETIVO: Avaliar a contaminação bacteriana da câmara anterior, após facoemulsificação não complicada, com tamanhos diferentes de incisões e lentes intra-oculares. MÉTODOS: Foi realizado estudo prospectivo randomizado, de 80 olhos de 80 pacientes, submetidos à facoemulsificação sob anestesia tópica, distribuídos aleatoriamente em dois grupos iguais. No grupo A foram alocados os pacientes submetidos à cirurgia com incisão de 3,0 mm, lente intra-ocular dobrável de silicone implantadas com injetor. No grupo B os pacientes foram submetidos à cirurgia com incisão de 5,8 mm e implante de lente intra-ocular de polimetilmetacrilato de peça única, com pinça. Ao final de cada cirurgia, uma amostra do líquido da câmara anterior foi colhida e semeada em meios de cultura para bactérias. RESULTADOS: A cultura do líquido da câmara anterior foi positiva em 2,5% dos casos do grupo A e em 5,0% do grupo B. Não houve diferença estatisticamente significante entre os dois grupos (chi2 = 0, 380, p> 0,05. CONCLUSÃO: O implante de lente intra-ocular através de incisão menor, não resultou em menor contaminação da câmara anterior na cirurgia de facoemulsificação.PURPOSE: To evaluate bacterial anterior chamber contamination following uncomplicated phacoemulsification with differents sizes of incisions. METHODS: Prospective randomized study, 80 eyes, 80 patients divided into two groups, were submitted to phacoemulsification with topical anaesthesia. In group A, with 40 patients, surgery was perfomed with 3.0 mm incision and silicone intraocular lens implant with injector. In group B the surgery was done with 5.8 mm incision and polymethylmethacrylate intraocular lens implant with forceps. Anterior chamber aspirate was taken for culture upon completion of surgery in each case. RESULTS: Anterior chamber cultures were positive in 2.5% of the cases in group A, and 5.0% in group B (chi-square test = 0.380, p>0.05, frequencies of

  8. Controlled light-exposure microscopy reduces photobleaching and phototoxicity in fluorescence live-cell imaging.

    NARCIS (Netherlands)

    Hoebe, R.A.; van Oven, C.H.; Gadella, Th.W.J.; Dhonukshe, P.B.; van Noorden, C.J.F.; Manders, E.M.M.

    2007-01-01

    Fluorescence microscopy of living cells enables visualization of the dynamics and interactions of intracellular molecules. However, fluorescence live-cell imaging is limited by photobleaching and phototoxicity induced by the excitation light. Here we describe controlled light-exposure microscopy

  9. Controlled light-exposure microscopy reduces photobleaching and phototoxicity in fluorescence live-cell imaging

    NARCIS (Netherlands)

    Hoebe, R. A.; van Oven, C. H.; Gadella, T. W. J.; Dhonukshe, P. B.; van Noorden, C. J. F.; Manders, E. M. M.

    2007-01-01

    Fluorescence microscopy of living cells enables visualization of the dynamics and interactions of intracellular molecules. However, fluorescence live-cell imaging is limited by photobleaching and phototoxicity induced by the excitation light. Here we describe controlled light-exposure microscopy (

  10. Reappraising the phototoxicity of tretinoin: a report of four controlled clinical trials.

    Science.gov (United States)

    Slade, Herbert B; Shroot, Braham; Feldman, Steven R; Cargill, D Innes; Stanfield, Joe

    2009-06-01

    Retinoids are photoreactive molecules found in skin and retinal tissue. The use of retinoids in pharmacologic doses, applied topically, raises the potential of phototoxicities. Recent review articles and current US drug labeling indicate that tretinoin is a phototoxin. In developing a new formulation of topical all-trans-retinoic acid (tretinoin), formal testing of dermal photoreactions was therefore undertaken. Four prospective, randomized, and controlled trials were carried out in healthy volunteers at two independent research facilities. Two trials examined phototoxicity following 24 h of drug exposure under occlusion (combined n=51), and two examined photoallergenicity following a 3-week, six dose induction phase (combined n=72) followed by challenge. No phototoxic or photoallergic reactions occurred with tretinoin 0.05% in a new gel formulation. The findings in these studies are consistent with previous studies of tretinoin in various formulations, and support the conclusion that tretinoin appears to be neither phototoxic nor photoallergenic in vivo.

  11. Lens Model

    DEFF Research Database (Denmark)

    Nash, Ulrik William

    2014-01-01

    Firms consist of people who make decisions to achieve goals. How do these people develop the expectations which underpin the choices they make? The lens model provides one answer to this question. It was developed by cognitive psychologist Egon Brunswik (1952) to illustrate his theory...

  12. Evaluation of acute skin irritation and phototoxicity by aqueous and ethanol fractions of Angelica keiskei

    OpenAIRE

    LEE, SANG-HAN

    2012-01-01

    In this study, to assess whether aqueous and ethanol fractions of Angelica keiskei induce acute skin irritation and phototoxicity, acute skin irritancy and phototoxicity tests were performed. The skin of rabbits or guinea pigs was treated with these fractions (100 mg/dose) and whether the animals sustained significant skin damage was determined. The data demonstrated that the aqueous and ethanol fractions of Angelica keiskei did not induce acute toxicity in the skin of the animals, as assesse...

  13. Surgical effect of traumatic lens dislocation with secondary glaucoma

    Directory of Open Access Journals (Sweden)

    Xiao-Dan Zhang

    2014-10-01

    Full Text Available AIM: To retrospectively evaluate the effect of lens extraction combined with vitrectomy to treat traumatic lens dislocation with secondary glaucoma.METHODS:Thirty-one eyes(31 casesof lens dislocation caused by blunt trauma with secondary glaucoma were treated respectively with cataract extraction combined with anterior vitrectomy, trabeculectomy and intraocular lens implantation. The visual acuity and pressure were observed 1wk, 1 and 3mo after operative. RESULTS:Thirty-one eyes were all complete the operation successfully, and 6 eyes were given combined trabeculectomy, 9 eyes were implanted anterior chamber intraocular lens implantation(IOLand 15 eyes were given posterior chamber suture fixation. Sixteen eyes were implanted in one-stage operation, while 8 eyes were implanted in two-stage operation. All intraocular pressure(IOPwere controlled to the normal level after operation and 23 eyes had visual acuity of more than 0.3.CONCLUSION:Lens extraction combined with vitrectomy is an effective method for treatment of lens dislocation with secondary glaucoma. In order to control the IOP and get well visual function, we should choose IOL implantation or trabeculectomy according to the patient's condition.

  14. Correção do astigmatismo irregular com lente intraocular tórica em um paciente com catarata e degeneração marginal pelúcida: relato de caso Toric intraocular lens implantation for cataract and irregular astigmatism related to pellucid marginal degeneration: case report

    Directory of Open Access Journals (Sweden)

    Ana Luiza Biancardi

    2012-12-01

    Full Text Available A degeneração marginal pelúcida (DMP é uma rara ectasia corneana cuja progressão resulta em astigmatismo irregular e baixa visual não corrigidos com óculos ou lentes de contato. O presente relato descreve um paciente com catarata e DMP que foi tratado com facoemulsificação e implante de lente intraocular tórica com recuperação da acuidade visual em ambos os olhos.Pellucid marginal degeneration (PMD is a rare corneal ectasia and its progression leads to irregular astigmatism and low vision that can not have spectacles or contact lens correction. This report describes a patient with low vision due to cataract and PMD that was treated with phacoemulsification and implantation of a toric intraocular lens with a satisfactory visual acuity outcome.

  15. Autorefraction versus subjective refraction in a radially asymmetric multifocal intraocular lens

    NARCIS (Netherlands)

    van der Linden, Jan Willem; Vrijman, Violette; Al-Saady, Rana; El-Saady, Rana; van der Meulen, Ivanka J.; Mourits, Maarten P.; Lapid-Gortzak, Ruth

    2014-01-01

    To evaluate whether the automated refraction (AR) correlates with subjective manifest (MR) refraction in eyes implanted with radially asymmetric multifocal intraocular lens (IOLs). This retrospective study evaluated 52 eyes (52 patients) implanted with a radially asymmetric multifocal IOL (LS-312

  16. Delayed phase of hematoporphyrin-induced phototoxicity: modulation by complement, leukocytes, and antihistamines

    Energy Technology Data Exchange (ETDEWEB)

    Lim, H.W.; Young, L.; Hagan, M.; Gigli, I.

    1985-02-01

    The role of complement, leukocytes, and histamine was investigated in the delayed phase of hematoporphyrin-induced phototoxicity in guinea pigs. The phototoxic response was quantified by the accumulation of intravenously injected (/sup 125/I)bovine serum albumin in the skin. There was a greater than 6-fold increase in the vascular response at the completion of irradiation, which subsided partially to reach a plateau of twice the preirradiation level between 0.5 h and 12 h. At 18 h, the vascular responsiveness returned to the baseline value. The 7 h timepoint was selected in this study to evaluate the modulation of the delayed phase. In complement-depleted guinea pigs, as well as in leukopenic animals, the enhancement in the vascular response was significantly suppressed (p vs control, less than 0.0001 and 0.0022, respectively). Cimetidine, when administered prior to irradiation, significantly suppressed the phototoxic response (p vs control, 0.0365). The combination of diphenhydramine and cimetidine, administered 6 h after the induction of phototoxicity, also suppressed the vascular response (p vs control, less than 0.0001). These data indicate that the expression of the delayed phase of hematoporphyrin-induced phototoxicity, similar to the early phase, requires the presence of an intact complement system, leukocytes, and histamine.

  17. [Management of post-traumatic aphakia and aniridia: Retrospective study of 17 patients undergoing scleral-sutured artificial iris intraocular lens implantation. Management of aphakia-aniridia with scleral-sutured artificial iris intraocular lenses].

    Science.gov (United States)

    Villemont, A-S; Kocaba, V; Janin-Manificat, H; Abouaf, L; Poli, M; Marty, A-S; Rabilloud, M; Fleury, J; Burillon, C

    2017-09-01

    To evaluate the long-term outcomes of artificial iris intraocular lenses sutured to the sclera for managing traumatic aphakia and aniridia. All consecutive cases receiving a Morcher ® combination implant from June 2008 to February 2016 in Edouard-Herriot Hospital (Lyon, France) were included in this single-center retrospective study. Visual acuity, subjective degree of glare, quality of life and surgical complications were evaluated. Seventeen eyes of 17 patients were included, among which 82% were male. The mean age was 42 years. The injuries consisted of 23.5% contusion and 70.5% open globe injuries, of which 41% were globe ruptures. There was one postoperative case. A penetrating keratoplasty was performed at the same time for eight eyes. The mean follow-up was 32 months. Best-corrected visual acuity improved in 41.2%, remained the same in 17.6% and decreased in 41.2% of our cases. Distance vision averaged 1±0.25 line better and near vision 2.2±0.32 lines better when visual acuity was quantifiable before surgery. Glare improved in 80% of patients and remained stable in 20%, decreasing on average from 3.3/5 [min. 3-max. 4; SD: 0.48] before surgery to 1.9/5 [min. 0-max. 4; SD: 1.197] after surgery. Regarding the esthetic results, 78% of the patients declared themselves reasonably to very satisfied; 57% reported no limitation of activities of daily living, and 43% reported mild limitation. Ocular hypertension and glaucoma, found in 40% of eyes, were the main postoperative complications. Implantation of prosthetic iris device combined with an intraocular lens appears to be safe and effective in reducing glare disability and improving visual acuity. Close, long-term monitoring is essential for the success of this surgery. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  18. Spontaneous dislocation of lens bag with acrylic lens after uneventful cataract surgery ? unusual complication of cataract surgery

    OpenAIRE

    Shah, Mehul A.; Shah, Shreya M.; Mehta, Ruchir; Shah, Prerna

    2015-01-01

    Introduction: Spontaneous dislocation of intraocular lens with bag is rare.Methods: We report a case of a 56-year-old male who presented with spontaneous anterior dislocation of an in-the-bag intraocular lens 3 years after manual small incision cataract surgery. He had undergone manual small incision cataract surgery with foldable acrylic intraocular lens implantation, and 18 months after cataract surgery ND: YAG capsulotomy with uneventful post capsulotomy follow-up. 17 months after capsul...

  19. An evaluation of chemical photoreactivity and the relationship to phototoxicity.

    Science.gov (United States)

    Kleinman, Mark H; Smith, Mark D; Kurali, Edit; Kleinpeter, Sarah; Jiang, Kaina; Zhang, Yongxia; Kennedy-Gabb, Sonya A; Lynch, Anthony M; Geddes, Chris D

    2010-11-01

    The existing regulatory guidance for photosafety testing of new drug products states that studies are warranted for those chemicals that both absorb light in the range of 290-700 nm, and that are either applied locally/topically, or "reach" (EMEA)/"significantly partition" (FDA) to the skin or eyes. The initial in vitro study recommended for the assessment of phototoxic potential is the 3T3 Neutral Red Uptake (NRU) Assay. The current study was undertaken to establish superior triggers for the initiation of biological photosafety testing. In this study, photophysical and photochemical parameters for 40 drug or drug-like molecules were studied. Principal Component Analysis (PCA), Partial Least Squares-Discriminant Analysis (PLS-DA), and a fivefold cross-validation PLS algorithm were used to evaluate the relationship between subsets of photophysical and photochemical parameters with the 3T3 NRU PIF/MPE (Photo Irritation Factor/Mean Photo Effect) results. The parameters most indicative of a 3T3 NRU positive PIF or MPE score were the extent of degradation in solution, the quantum yield of formation of singlet oxygen and the relative formation of superoxide anion. The results demonstrate that while absorption of light is critical to the induction of a light-induced process, it is the resultant events that may be used to predict the 3T3 NRU assay result. It is therefore proposed that the trigger for photosafety testing be revised to include a molecular basis for photoreactivity. From this limited investigation, estimated thresholds leading to 3T3 NRU positive results due to photodegradation, formation of singlet oxygen quantum yield or a relative superoxide anion formation value are proposed. Copyright © 2010 Elsevier Inc. All rights reserved.

  20. Relationship between preoperative axial length and myopic shift over 3 years after congenital cataract surgery with primary intraocular lens implantation at the National Institute of Ophthalmology of Peru, 2007-2011.

    Science.gov (United States)

    Valera Cornejo, Diego Alejandro; Flores Boza, Abel

    2018-01-01

    To determine the relationship between the preoperative axial length and the myopic shift over 3 years after congenital cataract surgery with primary intraocular lens implantation and other related factors. In this retrospective cohort study, the axial length was measured and assigned into 2 groups (>21.5 mm and ≤21.5 mm), visual axis obscuration, laterality of cataract, age of surgery and follow-up time were assessed and compared to the myopic shift. The mean myopic shift was 3.6 (standard deviation [SD]: 2.3) diopters (D) in all patients; 3.2 (3.3) and 3.9 (3.2) D for each group respectively ( p =0.359). In unilateral cataracts the mean myopic shift was 6.3 D and in bilateral cases was 3.0 D ( p =0.001). In bilateral cataracts, the shift was 2.6 D (SD: 2.0) and 3.4 D (SD: 1.8), respectively ( p =0.098). There was no relationship between the initial axial length and the myopic shift in all patients. Unilateral cataracts had a greater myopic shift over 3 years.

  1. Pars Plana Vitrectomy in Treatment of Lens Injury

    Directory of Open Access Journals (Sweden)

    Remzi Avcı

    2013-01-01

    Full Text Available Lens injury due to traumas may present as loss of capsule integrity, cataract, lens subluxation, or lens luxation. In addition, lens subluxation and lens luxation may occur in pseudophakic patients due to trauma. Clear corneal, scleral or sclero-corneal phacoemulsification surgery, pars plana vitrectomy, pars plana vitrectomy with phaco-fragmentation, or pars plana vitrectomy with removal through corneal incision techniques are used in the treatment of lens injury due to traumas. Intraocular lens can be implanted in the bag, sulcus, or anterior chamber during the surgery. Depending on the circumstances, scleral fixated intraocular lenses or iris-claw lenses may also be preferred. Rehabilitation of such patients is not of a great concern today, with the advanced level of vitreoretinal surgery and cataract surgery techniques and with the current state of technology. (Turk J Ophthalmol 2013; 43: 51-4

  2. Effect of Timing of Initial Cataract Surgery, Compliance to Amblyopia Therapy on Outcomes of Secondary Intraocular Lens Implantation in Chinese Children: A Retrospective Case Series

    Directory of Open Access Journals (Sweden)

    Liuyang Li

    2018-01-01

    Full Text Available Purpose. As a secondary analysis, we reassess the association of initial congenital cataract surgery times, compliance to amblyopia therapy, and visual outcomes for a long-term follow-up in a secondary IOL implantation. Methods. Retrospective review of records of all infants with congenital cataracts who underwent secondary IOL implantation in the Eye and ENT Hospital of Fudan University from January 1, 2001, to December 31, 2007, and the minimum follow-up period was 5 years. Multiple regression analysis was used and the possible confounding factors were also analyzed to assess the effect on visual outcome. Results. A total of 110 patients (male: 59.1% were included. The median (min–max age at cataract extraction and IOL implantation was 7.5 (3.0–15.0 and 35.0 (22.0–184.0 months, respectively, and the average follow-up period was 99.3 ± 23.6 months. The median (min–max BCVA at final follow-up was 0.20 (0.01–1.00. Compliance to amblyopia therapy was none, poor, and good in 21.8%, 24.5%, and 53.6%, respectively. Postoperative BCVA [logMAR, median (min–max 0.70 (0.00–2.00] linearly decreased with increasing cataract extraction time (per month (β=0.04, 95% CI: 0.03–0.06, p<0.0001 in multivariable models with laterality and compliance to amblyopia therapy adjusted. Good compliance to amblyopia therapy was associated with better BCVA (logMAR at last follow-up (β=−0.40, 95% CI = −0.53 to −0.27, p<0.0001 with laterality, opacity type, and extraction time adjusted. Conclusions. For Chinese infants with congenital cataract, an earlier primary congenital cataract surgery at an age of 3 to 15 months is associated with a better visual outcome. Good compliance to amblyopia therapy was also significant to visual outcome.

  3. Spontaneous dislocation of lens bag with acrylic lens after uneventful cataract surgery - unusual complication of cataract surgery.

    Science.gov (United States)

    Shah, Mehul A; Shah, Shreya M; Mehta, Ruchir; Shah, Prerna

    2015-01-01

    Spontaneous dislocation of intraocular lens with bag is rare. We report a case of a 56-year-old male who presented with spontaneous anterior dislocation of an in-the-bag intraocular lens 3 years after manual small incision cataract surgery. He had undergone manual small incision cataract surgery with foldable acrylic intraocular lens implantation, and 18 months after cataract surgery ND: YAG capsulotomy with uneventful post capsulotomy follow-up. 17 months after capsulotomy, the patient presented with sudden decrease of vision. On anterior segment examination, the intraocular lens with bag was dislocated into the anterior chamber. It was managed with intraocular lens explantation with bag, anterior vitrectomy and sclera fixated intraocular lens. Spontaneous intraocular lens dislocation with bag is possible after 1.5 years of uneventful surgery which may be managed using different techniques.

  4. ECTOPIC LENS EXTRACTION IN CHILDREN

    Directory of Open Access Journals (Sweden)

    Vladimir Pfeifer

    2002-12-01

    Full Text Available Background. Ectopia lentis continues to be a therapeutic challenge for ophthalmologists. It can occur as an isolated condition, after ocular trauma, in association with other ocular disorders, as part of a systemic mesodermal disease or a complication of general metabolic disorders. Minimal subluxation of the lens may cause no visual symptoms, but in more advanced cases serious optical disturbances arise. The most important is amblyopia. Surgical treatment options include iris manipulation, lens discission, aspiration, intracapsular or extracapsular extraction, and pars plana lensectomy. The choice of surgical technique remains controversial, in part because of the historically poor visual results and high rate of perioperative complications, including vitreous loss and retinal detachment.Methods. We describe a surgical technique based on the use of the Cionni endocapsular tension ring, dry irrigation aspiration of lens material, centration of the capsular bag and foldable intraocular lens implantation into the bag. With mentioned surgical technique 8 patients were operated; 4 boys and 4 girls, together 11 eyes.Results. The final BCVA after follow up period improved in 9 eyes and it remained the same as before operation in one eye. Statistical comparison of preoperative and postoperative visual acuities showed significant improvement. On the other hand there was no correlation between preoperative and postoperative visual acuity.Conclusions. This surgical procedure is an alternative approach in solving this challenging cases of ectopia lentis with good postoperative visual rehabilitation.

  5. Contact lens in keratoconus

    Directory of Open Access Journals (Sweden)

    Varsha M Rathi

    2013-01-01

    Full Text Available Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP lenses, soft and soft toric lenses, piggy back contact lenses (PBCL, hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the English language with the keywords keratoconus and various contact lenses such as Rose k lens, RGP lens, hybrid lens, scleral lens and PBCL.

  6. Contact lens in keratoconus

    Science.gov (United States)

    Rathi, Varsha M; Mandathara, Preeji S; Dumpati, Srikanth

    2013-01-01

    Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP) lenses, soft and soft toric lenses, piggy back contact lenses (PBCL), hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the English language with the keywords keratoconus and various contact lenses such as Rose k lens, RGP lens, hybrid lens, scleral lens and PBCL. PMID:23925325

  7. Application of the equivalency factor concept to the phototoxicity and -genotoxicity of furocoumarin mixtures.

    Science.gov (United States)

    Raquet, Nicole; Schrenk, Dieter

    2014-06-01

    Furocoumarins (FCs) are natural constituents widely occurring in plants used as food or in phytomedicines, cosmetics, etc. Some FCs exert dermal photo-toxicity and -genotoxicity when combined with UVA irradiation. For a few congeners, skin tumor formation has been described in humans and laboratory animals. Since almost no information is available on the photo-toxic properties of several congeners, we analyzed the photo-cytotoxic, photo-mutagenic, and photo-clastogenic properties in V79 cells for thirteen naturally occurring FCs, and for the coumarin limettin. Furthermore, nine FC mixtures including one mixture based on the FC pattern of an Angelica archangelica extract were tested in the same assays. We found that the concept of relative potency factors for photo-cytotoxic, -mutagenic, and -clastogenicpotencies of FCs, setting the value for 5-methoxypsoralen at 1.00, was applicable to all congeners tested. The concept was used successfully to describe the photo-toxic properties of binary mixtures of 5- and 8-methoxypsoralen. Furthermore, the photo-genotoxic (photo-mutagenic and -clastogenic) properties of complex FC mixtures comprising up to nine different congeners could be predicted. These data suggest that FCs can differ widely in their photo-toxic and photo-genotoxic properties but show relatively strict additivity with respect to their on target-effects when occurring as complex mixtures. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Antidiabetics and diuretics show phototoxicity in HaCaT cells

    Science.gov (United States)

    Selvaag, Edgar; Petersen, Anita B.; Gniadecki, Robert; Thorn, Tine; Wulf, Hans Christian

    2001-10-01

    The antidiabetics tolbutamide, glibenclamide, and glipizide, and the diuretics bendroflumethiazide, butizide, furosemide, hydrochlorothiazide, and trichlormethiazide were investigated for potential phototoxicity in the HaCaT cell line. The cells were incubated with the drugs and then exposed to UVA1 irradiation. The effects of the antioxidants L-ascorbic acid, and (alpha) -tocopherol on oxidative DNA damage were assessed. Bendroflumethiazide, furosemide, hydrochlorothiazide, trichlormethiazide, or tolbutamide induced dose-dependent phototoxicity. Cells incubated with bendroflumethiazide, tolbutamide, and glibenclamide, and irradiated with UVA1 demonstrated an increased oxidative DNA damage. Pre-treatment with L-ascorbic acid, or (alpha) -tocopherol, suppressed the UVA-induced DNA damage in cells incubated with 1 mM of bendroflumethiazide, furosemide, glibenclamide, glipizide, tolbutamide, and trichloromethiazide, further implying the involvement of reactive oxygen species in the phototoxic DNA damage. These results may indicate a link between phototoxic and photocancerogenic potential of the sulfonamide-derived oral antidiabetic and diuretic drugs, as it has previously been recognized for psoralen, chlorpromazine, and fluoroquinolones. Excessive exposure to UV light may be deleterious for patients treated with these drugs.

  9. Sensitivity of different cell lines to phototoxic effect of disulfonated chloroaluminium phthalocyanine

    Czech Academy of Sciences Publication Activity Database

    Kolářová, H.; Lenobel, René; Kolář, P.; Strnad, Miroslav

    2007-01-01

    Roč. 21, č. 7 (2007), s. 1304-1306 ISSN 0887-2333 R&D Projects: GA ČR GA522/06/0108 Institutional research plan: CEZ:AV0Z50380511 Source of funding: V - iné verejné zdroje Keywords : Phototoxicity * cell lines * laser Subject RIV: ED - Physiology Impact factor: 2.193, year: 2007

  10. Phototoxicity and Dosimetry of Nano-scale Titanium Dioxide in Aquatic Organisms

    Science.gov (United States)

    We have been testing nanoscale TiO2 (primarily Evonik P25) in acute exposures to identify and quantify its phototoxicity under solar simulated radiation (SSR), and to develop dose metrics reflective of both nano-scale properties and the photon component of its potency. Several e...

  11. Impact of natural organic matter on particle behavior and phototoxicity of titanium dioxide nanoparticles

    Science.gov (United States)

    Due to their inherent phototoxicity and inevitable environmental release, titanium dioxide nanoparticles (nano-TiO2) are increasingly studied in the field of aquatic toxicology. One of the particular interests is the interactions between nano-TiO2 and natural organic matter (NOM)...

  12. In Vitro Phototoxicity and Hazard Identification of Nano-scale Titanium Dioxide

    Science.gov (United States)

    Nano-titanium dioxide (nano-Ti02) catalyzes many reactions under UV radiation and is hypothesized to cause phototoxicity. A human-derived line of retinal pigment epithelial cells (ARPE-19) was treated with six different samples of nano-Ti02 and exposed to UVA radiation. The Ti02 ...

  13. Photocatalytic ROS production and phototoxicity of titanium dioxide nanoparticles is dependent on solar UV radiation spectrum

    Science.gov (United States)

    Generation of reactive oxygen species (ROS) by titanium dioxide nanoparticles (nano-TiO2) and its consequent phototoxicity to Daphnia magna were measured under different solar UV radiation spectrum by applying a series of optical filters in a solar simulator. Removing UVB (280-32...

  14. Phototoxic potential of undispersed and dispersed fresh and weathered Macondo crude oils to Gulf of Mexico Marine Organisms.

    Science.gov (United States)

    Finch, Bryson E; Marzooghi, Solmaz; Di Toro, Dominic M; Stubblefield, William A

    2017-10-01

    Crude oils contain a mixture of hydrocarbons, including phototoxic polycyclic aromatic hydrocarbons (PAHs) that have the ability to absorb ultraviolet (UV) light. Absorption of UV light by PAHs can substantially increase their toxicity to marine organisms. The objective of the present study was to examine the potential for phototoxicity of fresh and naturally weathered Macondo crude oils alone and in combination with the dispersant Corexit 9500 to mysid shrimp (Americamysis bahia), inland silverside (Menidia beryllina), sheepshead minnow (Cyprinodon variegatus), and Gulf killifish (Fundulus grandis). Acute toxicity tests were conducted using combinations of natural or artificial sunlight and low-energy water-accommodated fractions (WAFs) of fresh and weathered Macondo crude oils collected from the Gulf of Mexico. Studies were also conducted to compare the phototoxicity resulting from natural and artificial sunlight. Fresh Macondo crude oil was more phototoxic than weathered crude oils, both in the presence and in the absence of UV light. Differences in toxicity between fresh and weathered crude oils were likely attributed to lighter-ringed PAHs in fresh crude oils. Phototoxic PAHs were relatively resistant to weathering compared with lighter-ringed PAHs. The addition of Corexit 9500 to crude oil increased toxicity compared with tests with crude oil alone, by increasing phototoxic PAH concentrations in WAFs. Macondo crude oils had the potential to be phototoxic to Gulf of Mexico marine organisms if specific light conditions and PAH concentrations were present during the Deepwater Horizon oil spill. Environ Toxicol Chem 2017;36:2640-2650. © 2017 SETAC. © 2017 SETAC.

  15. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... lens because they can be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, ... Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume Contacts May Contain Chemicals Harmful to Eyes ...

  16. Implante de lente intraocular en niños como solución a los problemas sociales de la ceguera por catarata congénita Intraocular lens implants for children as a solution to social problems caused by blindness from congenital cataract

    Directory of Open Access Journals (Sweden)

    Rosa María Naranjo Fernández

    2011-12-01

    congenital cataract ranges from 1 to 4 per 10 000 children in underdeveloped countries and 0,1 to 0,4 in industrialized countries. In Cuba, 2,1 million inhabitants are under 15 years of age and the congenital cataract is regarded as the second cause of infantile blindness. In the last 20 years, the surgical treatment of cataract in children has completely changed based on the remarkable improvement of the surgical techniques. In our country, the pediatric cataract surgery with intraocular lens implantation began in 1990 after the inauguration of the Ocular Microsurgery Center in 1988. The importance of this pediatric cataract surgery with intraocular lens implants was shown as a solution to the social problems caused by the visual deficit of inadequately treated patients, since the application of modern technology improves the quality of life of children both at social and educational level, and allows fully re-inserting them into the society.

  17. The 3T3 neutral red uptake phototoxicity test: practical experience and implications for phototoxicity testing--the report of an ECVAM-EFPIA workshop.

    Science.gov (United States)

    Ceridono, Mara; Tellner, Pär; Bauer, Daniel; Barroso, João; Alépée, Nathalie; Corvi, Raffaella; De Smedt, Ann; Fellows, Mick D; Gibbs, Neil K; Heisler, Eckhard; Jacobs, Abigail; Jirova, Dagmar; Jones, David; Kandárová, Helena; Kasper, Peter; Akunda, Jacqueline Kinyamu; Krul, Cyrille; Learn, Douglas; Liebsch, Manfred; Lynch, Anthony M; Muster, Wolfgang; Nakamura, Kazuichi; Nash, J Frank; Pfannenbecker, Uwe; Phillips, Gareth; Robles, Catherine; Rogiers, Vera; Van De Water, Femke; Liminga, Ulla Wändel; Vohr, Hans-Werner; Wattrelos, Olivier; Woods, Julie; Zuang, Valérie; Kreysa, Joachim; Wilcox, Phil

    2012-08-01

    This is the report from the "ECVAM-EFPIA workshop on 3T3 NRU Phototoxicity Test: Practical Experience and Implications for Phototoxicity Testing", jointly organized by ECVAM and EFPIA and held on the 25-27 October 2010 in Somma Lombardo, Italy. The European Centre for the Validation of Alternative Methods (ECVAM) was established in 1991 within the European Commission Joint Research, based on a Communication from the European Commission (1991). The main objective of ECVAM is to promote the scientific and regulatory acceptance of alternative methods which are of importance to the biosciences and which reduce, refine and replace the use of laboratory animals. The European Federation of Pharmaceuticals Industries and Association (EFPIA) represent the pharmaceutical industry operating in Europe. Through its direct membership of 31 national associations and 40 leading pharmaceutical companies, EFPIA is the voice on the EU scene of 2200 companies committed to researching, developing and bringing to patients new medicines that improve health and the quality of life around the world. The workshop, co-chaired by Joachim Kreysa (ECVAM) and Phil Wilcox (GSK, EFPIA) involved thirty-five experts from academia, regulatory authorities and industry, invited to contribute with their experiences in the field of phototoxicology. The main objectives of the workshop were: -to present 'in use' experience of the pharmaceutical industry with the 3T3 Neutral Red Uptake Phototoxicity Test (3T3 NRU-PT), -to discuss why it differs from the results in the original validation exercise, -to discuss technical issues and consider ways to improve the usability of the 3T3 NRU-PT for (non-topical) pharmaceuticals, e.g., by modifying the threshold of chemical light absorption to trigger photo-toxicological testing, and by modifying technical aspects of the assay, or adjusting the criteria used to classify a positive response. During the workshop, the assay methodology was reviewed by comparing the OECD

  18. Incidência de opacificação de cápsula posterior em pacientes submetidos à facoemulsificação e implante de lentes intra-oculares acrílicas hidrofílicas expansíveis Incidence of posterior capsule opacification in patients submitted to phacoemulsification and expandable acrylic intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Hilton Arcoverde Gonçalves de Medeiros

    2006-06-01

    Full Text Available OBJETIVO: Avaliar prospectivamente os resultados das lentes intra-oculares de polímeros expansíveis implantadas em pacientes submetidos à facoemulsificação, quanto à incidência de opacificação de cápsula posterior, levando em consideração a biocompatibilidade das lentes expansíveis. MÉTODOS: O grupo de estudo foi composto por 830 pacientes, 1.200 olhos, que foram submetidos a facoemulsificação, utilizando a mesma técnica, variando-se apenas o diâmetro da capsulorrexe, pelo mesmo cirurgião, no período de 1998 a 2002, com implante de lente intra-ocular hidrofílica expansível. O acompanhamento médio foi de 2,4 anos, variando de seis meses a quatro anos. RESULTADOS: O número total de opacificação de cápsula posterior foi de 54 casos. CONCLUSÃO: A incidência de opacificação de cápsula posterior encontrada no grupo foi de 4,6%.PURPOSE: To evaluate prospectively the results of expandable acrylic intraocular lenses in patients submitted to phacoemulsification as regard posterior capsule opacification. METHODS: The study group consisted of 830 patients, 1,200 eyes that underwent phacoemulsification from 1998 to 2002, by the same surgeon, using the same technique but with different diameters of capsulorrhexis, with expandable hydrophilic acrylic intraocular lens implantation. The mean follow-up was 2.4 years, ranging from 6 months to 4 years. RESULTS: The total number of posterior capsule opacification was 54 cases. CONCLUSIONS: The incidence of posterior capsule opacification was 4.6% in these patients.

  19. Evaluation of the phototoxicity of unsubstituted and alkylated polycyclic aromatic hydrocarbons to mysid shrimp (Americamysis bahia): Validation of predictive models.

    Science.gov (United States)

    Finch, Bryson E; Marzooghi, Solmaz; Di Toro, Dominic M; Stubblefield, William A

    2017-08-01

    Crude oils are composed of an assortment of hydrocarbons, some of which are polycyclic aromatic hydrocarbons (PAHs). Polycyclic aromatic hydrocarbons are of particular interest due to their narcotic and potential phototoxic effects. Several studies have examined the phototoxicity of individual PAHs and fresh and weathered crude oils, and several models have been developed to predict PAH toxicity. Fingerprint analyses of oils have shown that PAHs in crude oils are predominantly alkylated. However, current models for estimating PAH phototoxicity assume toxic equivalence between unsubstituted (i.e., parent) and alkyl-substituted compounds. This approach may be incorrect if substantial differences in toxic potency exist between unsubstituted and substituted PAHs. The objective of the present study was to examine the narcotic and photo-enhanced toxicity of commercially available unsubstituted and alkylated PAHs to mysid shrimp (Americamysis bahia). Data were used to validate predictive models of phototoxicity based on the highest occupied molecular orbital-lowest unoccupied molecular orbital (HOMO-LUMO) gap approach and to develop relative effect potencies. Results demonstrated that photo-enhanced toxicity increased with increasing methylation and that phototoxic PAH potencies vary significantly among unsubstituted compounds. Overall, predictive models based on the HOMO-LUMO gap were relatively accurate in predicting phototoxicity for unsubstituted PAHs but are limited to qualitative assessments. Environ Toxicol Chem 2017;36:2043-2049. © 2017 SETAC. © 2017 SETAC.

  20. Influence of the environment and phototoxicity of the live cell imaging system at IMP microbeam facility

    Science.gov (United States)

    Liu, Wenjing; Du, Guanghua; Guo, Jinlong; Wu, Ruqun; Wei, Junzhe; Chen, Hao; Li, Yaning; Zhao, Jing; Li, Xiaoyue

    2017-08-01

    To investigate the spatiotemporal dynamics of DNA damage and repair after the ion irradiation, an online live cell imaging system has been established based on the microbeam facility at Institute of Modern Physics (IMP). The system could provide a sterile and physiological environment by making use of heating plate and live cell imaging solution. The phototoxicity was investigated through the evaluation of DNA repair protein XRCC1 foci formed in HT1080-RFP cells during the imaging exposure. The intensity of the foci induced by phototoxicity was much lower compared with that of the foci induced by heavy ion hits. The results showed that although spontaneous foci were formed due to RFP exposure during live cell imaging, they had little impact on the analysis of the recruitment kinetics of XRCC1 in the foci induced by the ion irradiation.

  1. The Phototoxicity of Blue Light on the Functional Properties of the Retinal Pigment Epithelium

    Science.gov (United States)

    1989-05-01

    The phototoxic effect of blue light on isolated pigment epithelium will be investigated. The emphasis will be on functional changes rather than a...integrity of the barrier system and the transport system and the transport systems known to operate in the pigment epithelium. The effects of blue ... light on leucine transport across the isolated bovine retinal pigment epithelium (RPE) have been continued to determine if Vitamin E and melatonin

  2. In Vitro Cytotoxicity and Phototoxicity Assessment of Acylglutamate Surfactants Using a Human Keratinocyte Cell Line

    Directory of Open Access Journals (Sweden)

    Abhay Kyadarkunte

    2014-07-01

    Full Text Available In the current study, human keratinocyte cell line was used as in vitro cell culture model to elucidate the effects of the fatty acid chain length of acylglutamate (amino acid-based surfactant namely, sodium cocoyl glutamate, sodium lauroyl glutamate, and sodium myristoyl glutamate on their cytotoxicity and the ultraviolet B induced phototoxicity. The endpoint used to assess toxicity was a tetrazolium-based assay whereas, the phototoxic potential of acylglutamate surfactants was predicted using two models namely, the Photo-Irritation Factor and Mean Photo Effect. The results of this study showed that the fatty acid chain length of acylglutamate greatly influences toxic effects on human keratinocyte cells. In addition, all the acylglutamate surfactants tested on human keratinocyte cells demonstrated significantly less cytotoxicity (when irradiated and non-irradiated with ultraviolet B light; p < 0.05 and no phototoxic potential was observed in any of the acylglutamate surfactants, when compared with the positive control chlorpromazine. In conclusion, the in vitro studies confirm the suitability of sodium lauroyl glutamate destined for the synthesis and stabilization of lipid nanoparticles.

  3. Phototoxic effects of PAH and UVA exposure on molecular responses and developmental success in coral larvae

    KAUST Repository

    Overmans, Sebastian

    2018-03-09

    Exposure to polycyclic aromatic carbons (PAHs) poses a growing risk to coral reefs due to increasing shipping and petroleum extraction in tropical waters. Damaging effects of specific PAHs can be further enhanced by the presence of ultraviolet radiation, known as phototoxicity. We tested phototoxic effects of the PAHs anthracene and phenanthrene on larvae of the scleractinian coral Acropora tenuis in the presence and absence of UVA (320–400 nm). Activity of superoxide dismutase (SOD) enzyme was reduced by anthracene while phenanthrene and UVA exposure did not have any effect. Gene expression of MnSod remained constant across all treatments. The genes Catalase, Hsp70 and Hsp90 showed increased expression levels in larvae exposed to anthracene, but not phenanthrene. Gene expression of p53 was upregulated in the presence of UVA, but downregulated when exposed to PAHs. The influence on stress-related biochemical pathways and gene expresson in A. tenuis larvae was considerably greater for anthracene than phenanthrene, and UVA-induced phototoxicity was only evident for anthracene. The combined effects of UVA and PAH exposure on larval survival and metamorphosis paralleled the sub-lethal stress responses, clearly highlighting the interaction of UVA on anthracene toxicity and ultimately the coral’s development.

  4. Invited review article: the electrostatic plasma lens.

    Science.gov (United States)

    Goncharov, Alexey

    2013-02-01

    The fundamental principles, experimental results, and potential applications of the electrostatic plasma lens for focusing and manipulating high-current, energetic, heavy ion beams are reviewed. First described almost 50 years ago, this optical beam device provides space charge neutralization of the ion beam within the lens volume, and thus provides an effective and unique tool for focusing high current beams where a high degree of neutralization is essential to prevent beam blow-up. Short and long lenses have been explored, and a lens in which the magnetic field is provided by rare-earth permanent magnets has been demonstrated. Applications include the use of this kind of optical tool for laboratory ion beam manipulation, high dose ion implantation, heavy ion accelerator injection, in heavy ion fusion, and other high technology.

  5. Signal-enhancement reflective pulse oximeter with Fresnel lens

    Science.gov (United States)

    Chung, Shuang-Chao; Sun, Ching-Cherng

    2016-09-01

    In this paper, a new reflective pulse oximeter is proposed and demonstrated with implanting a Fresnel lens, which enhances the reflected signal. An optical simulation model incorporated with human skin characteristics is presented to evaluate the capability of the Fresnel lens. In addition, the distance between the light emitting diode and the photodiode is optimized. Compared with the other reflective oximeters, the reflected signal light detected by the photodiode is enhanced to more than 140%.

  6. Medicolegal hazards of intraocular lens implanting.

    Science.gov (United States)

    Bettman, J W

    1978-10-01

    If the result of cataract extraction is not good, patients with relatively good preoperative vision are more likely to sue than those with poor preoperative vision. One of the usual indications for use of a pseudophakos is good vision in one eye. At times the preoperative acuity in the operated eye is not bad. This creates an unfavorable risk:benefit ratio. Other factors that add to the risk of litigation are publicity in the lay press and problems with properly informing the patient to obtain consent.

  7. Photoreactivity of biologically active compounds. VIII. Photosensitized polymerization of lens proteins by antimalarial drugs in vitro.

    Science.gov (United States)

    Kristensen, S; Wang, R H; Tønnesen, H H; Dillon, J; Roberts, J E

    1995-02-01

    The drugs commonly used in the treatment of malaria are photochemically unstable. Several of these compounds cause dermal and ocular toxic reactions that may be light induced. The in vitro photopolymerization of calf lens proteins in the presence of antimalarial drugs was studied as part of a screening of the photochemical properties and phototoxic capabilities of these compounds. The pseudo-first-order rate constant for the reaction was calculated, and related to the amount of light absorbed by the compounds in order to determine the relative photosensitizing effect of each drug. The reaction mechanisms were evaluated by adding a variety of quenchers to the reaction medium during irradiation. Based on the results obtained in this study and previous knowledge about the pharmacokinetic behavior of these compounds, several of the drugs investigated have to be considered as potential photosensitizers in the human lens, the retina and the skin.

  8. REFRACTIVE NEUTRON LENS

    OpenAIRE

    Petrov, P. V.; Kolchevsky, N. N.

    2013-01-01

    Compound concave refractive lenses are used for focusing neutron beam. Investigations of spectral and focusing properties of a refractive neutron lens are presented. Resolution of the imaging system on the base of refractive neutron lenses depends on material properties and parameters of neutron source. Model of refractive neutron lens are proposed. Results of calculation diffraction resolution and focal depth of refractive neutron lens are discussed.

  9. Contact lens in keratoconus

    OpenAIRE

    Rathi, Varsha M; Mandathara, Preeji S; Dumpati, Srikanth

    2013-01-01

    Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP) lenses, soft and soft toric lenses, piggy back contact lenses (PBCL), hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the En...

  10. Synergic phototoxic effect of visible light or Gallium-Arsenide laser in the presence of different photo-sensitizers on Porphyromonas gingivalis and Fusobacterium nucleatum

    Directory of Open Access Journals (Sweden)

    Habibollah Ghanbari

    2015-01-01

    Conclusion: Within the limitations of this study, the synergic phototoxic effect of visible light in combination with each of the photosensitizers on P. gingivalis and F. nucleatum. However, the synergic phototoxic effect of laser exposure and hydrogen peroxide and curcumin as photosensitizers on F. nucleatum was not shown.

  11. Potent phototoxicity of marine bunker oil to translucent herring embryos after prolonged weathering.

    Directory of Open Access Journals (Sweden)

    John P Incardona

    Full Text Available Pacific herring embryos (Clupea pallasi spawned three months following the Cosco Busan bunker oil spill in San Francisco Bay showed high rates of late embryonic mortality in the intertidal zone at oiled sites. Dead embryos developed to the hatching stage (e.g. fully pigmented eyes before suffering extensive tissue deterioration. In contrast, embryos incubated subtidally at oiled sites showed evidence of sublethal oil exposure (petroleum-induced cardiac toxicity with very low rates of mortality. These field findings suggested an enhancement of oil toxicity through an interaction between oil and another environmental stressor in the intertidal zone, such as higher levels of sunlight-derived ultraviolet (UV radiation. We tested this hypothesis by exposing herring embryos to both trace levels of weathered Cosco Busan bunker oil and sunlight, with and without protection from UV radiation. Cosco Busan oil and UV co-exposure were both necessary and sufficient to induce an acutely lethal necrotic syndrome in hatching stage embryos that closely mimicked the condition of dead embryos sampled from oiled sites. Tissue levels of known phototoxic polycyclic aromatic compounds were too low to explain the observed degree of phototoxicity, indicating the presence of other unidentified or unmeasured phototoxic compounds derived from bunker oil. These findings provide a parsimonious explanation for the unexpectedly high losses of intertidal herring spawn following the Cosco Busan spill. The chemical composition and associated toxicity of bunker oils should be more thoroughly evaluated to better understand and anticipate the ecological impacts of vessel-derived spills associated with an expanding global transportation network.

  12. Evaluation of phototoxicity of dendritic porphyrin-based phosphorescent oxygen probes: an in vitro study†

    Science.gov (United States)

    Lebedev, Artem Y.; Marchi, Enrico; Yuan, Min; Esipova, Tatiana V.; Bergamini, Giacomo; Wilson, David F.

    2013-01-01

    Biological oxygen measurements by phosphorescence quenching make use of exogenous phosphorescent probes, which are introduced directly into the medium of interest (e.g. blood or interstitial fluid) where they serve as molecular sensors for oxygen. The byproduct of the quenching reaction is singlet oxygen, a highly reactive species capable of damaging biological tissue. Consequently, potential probe phototoxicity is a concern for biological applications. Herein, we compared the ability of polyethyleneglycol (PEG)-coated Pd tetrabenzoporphyrin (PdTBP)-based dendritic nanoprobes of three successive generations to sensitize singlet oxygen. It was found that the size of the dendrimer has practically no effect on the singlet oxygen sensitization efficiency in spite of the strong attenuation of the triplet quenching rate with an increase in the dendrimer generation. This unexpected result is due to the fact that the lifetime of the PdTBP triplet state in the absence of oxygen increases with dendritic generation, thus compensating for the concomitant decrease in the rate of quenching. Nevertheless, in spite of their ability to sensitize singlet oxygen, the phosphorescent probes were found to be non-phototoxic when compared with the commonly used photodynamic drug Photofrin in a standard cell-survival assay. The lack of phototoxicity is presumably due to the inability of PEGylated probes to associate with cell surfaces and/or penetrate cellular membranes. In contrast, conventional photosensitizers bind to cell components and act by generating singlet oxygen inside or in the immediate vicinity of cellular organelles. Therefore, PEGylated dendritic probes are safe to use for tissue oxygen measurements as long as the light doses are less than or equal to those commonly employed in photodynamic therapy. PMID:21409208

  13. Phototoxicity and chronic toxicity of methyl paraben and 1,2-hexanediol in Daphnia magna.

    Science.gov (United States)

    Lee, Jiyun; Park, Nayeon; Kho, Younglim; Lee, Kiyoung; Ji, Kyunghee

    2017-01-01

    Parabens are used as antimicrobial preservatives in consumer products. Exposure to methylparaben (MP) has been associated with adverse health outcomes, therefore, an alternative compound, 1,2-hexanediol (1,2-H), has been applied for cosmetics. In the present study, the phototoxicity of MP and 1,2-H, as well as the toxic effect caused by chronic exposure, were investigated using Daphnia magna. The 48 h acute toxicity tests with D. magna were conducted under indoor or ultraviolet (UV) light irradiation conditions, i.e., exposure to 4 h/d sunlight. Changes in the transcription of genes related to oxidative stress were determined in D. magna juveniles, to investigate the underlying mechanism of phototoxicity. The 21 d chronic toxicity tests of MP and 1,2-H were performed under indoor light irradiation. Exposure to MP under environmental level of UV light was more detrimental to D. magna. Transcripts of catalase and glutathione-S-transferase genes in D. magna was significantly increased by co-exposure to MP and UV light. After 21 d of chronic exposure to MP and 1,2-H, the reproduction no-observed effect concentrations for D. magna were 1 and >10 mg/L, respectively. The present study showed that exposure to UV could magnify the toxicity of MP on daphnids. Although acute and chronic toxicities of 1,2-H were generally lower than those of MP, its effects on other aquatic organisms should not be ignored. Further studies are needed to identify other mechanisms of MP phototoxicity.

  14. Phototoxicity of TiO2 nanoparticles to a freshwater benthic amphipod: Are benthic systems at risk?

    International Nuclear Information System (INIS)

    Li, Shibin; Wallis, Lindsay K.; Ma, Hongbo; Diamond, Stephen A.

    2014-01-01

    This study investigated phototoxicity of TiO 2 nanoparticles (nano-TiO 2 ) to a freshwater benthic amphipod (Hyalella azteca) using 48-h and 96-h bioassays. Thorough monitoring of particle interactions with exposure media (Lake Superior water, LSW) and the surface of organisms was performed using dynamic light scattering, UV/Vis spectroscopy, and Scanning Electron Microscopy. Large agglomeration and sedimentation (> 77%) in LSW was observed after 0.5 h. A simulated solar radiation (SSR)-favored surface attachment of nanoparticles was observed, indicating enhanced phototoxicity with the increased attachment. A 96-h median lethal concentration (LC50) of 29.9 mg/L in H. azteca was calculated, with a daily 4-h UV exposure of 2.2 W/m 2 . Phototoxicity of nano-TiO 2 under SSR had a 21-fold increase as compared to that under ambient laboratory light. This phototoxicity was also dependent on UV dose, with calculated LC50s around 22.9 (95% CI, 20.5–23.3) Wh/m 2 when exposed to 20 mg/L nano-TiO 2 . Also, H. azteca exhibited negative phototaxis in the presence of shelters, indicating that other factors might play a role in environmental systems. Finally, the environmental implications of nano-TiO 2 to benthic organisms were illustrated, emphasizing the importance of various environmental factors in the ultimate phototoxicity. This increased phototoxicity and its complex interactions with various environmental factors suggest further investigations are needed for future risk assessment of photoactive nanomaterials to benthic organisms. - Graphical abstract: Display Omitted - Highlights: •Large aggregation of TiO 2 nanoparticles in Lake Superior water was observed. •Phototoxicity was dependent on the dose of both solar radiation and nanoparticle. •A solar radiation favored surface attachment of nanoparticles was observed. •Hyalella azteca exhibited negative phototaxis in the presence of shelters. •Factors influencing phototoxicity in the real environment were

  15. Comparative phototoxicity of nanoparticulate and bulk ZnO to a free-living nematode Caenorhabditis elegans: The importance of illumination mode and primary particle size

    International Nuclear Information System (INIS)

    Ma, H.; Kabengi, N.J.; Bertsch, P.M.; Unrine, J.M.; Glenn, T.C.; Williams, P.L.

    2011-01-01

    The present study evaluated phototoxicity of nanoparticulate ZnO and bulk-ZnO under natural sunlight (NSL) versus ambient artificial laboratory light (AALL) illumination to a free-living nematode Caenorhabditis elegans. Phototoxicity of nano-ZnO and bulk-ZnO was largely dependent on illumination method as 2-h exposure under NSL caused significantly greater mortality in C. elegans than under AALL. This phototoxicity was closely related to photocatalytic reactive oxygen species (ROS) generation by the ZnO particles as indicated by concomitant methylene blue photodegradation. Both materials caused mortality in C. elegans under AALL during 24-h exposure although neither degraded methylene blue, suggesting mechanisms of toxicity other than photocatalytic ROS generation were involved. Particle dissolution of ZnO did not appear to play an important role in the toxicity observed in this study. Nano-ZnO showed greater phototoxicity than bulk-ZnO despite their similar size of aggregates, suggesting primary particle size is more important than aggregate size in determining phototoxicity. - Highlights: → Phototoxicity of nano- or bulk-ZnO was enhanced by natural sunlight illumination. → This phototoxicity was well-correlated to photocatalytic ROS generation. → Toxicity of ZnO particles not related to photocatalytic ROS generation was also observed. → Nano-ZnO showed greater phototoxicity than bulk-ZnO due to its greater total surface area per unit mass. → Primary particle size appeared to be more important than aggregate size in determining phototoxicity. - Phototoxicity of nanoparticulate and bulk ZnO was greatly enhanced by natural sunlight illumination compared to artificial laboratory light illumination.

  16. Breast Implants

    Science.gov (United States)

    ... Medical Procedures Implants and Prosthetics Breast Implants Breast Implants Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Breast implants are medical devices that are implanted under the ...

  17. Contrast sensitivity after refractive lens exchange with a multifocal diffractive aspheric intraocular lens

    Directory of Open Access Journals (Sweden)

    Teresa Ferrer-Blasco

    2013-04-01

    Full Text Available PURPOSE: To evaluate distance and near contrast sensitivity (CS under photopic and mesopic conditions before and after refractive lens exchange (RLE and implantation of the aspheric AcrySof®ReSTOR® (SN6AD3 model intraocular lens (IOL. METHODS:Seventy-four eyes of 37 patients after RLE underwent bilateral implantation with the aspheric AcrySof ReSTOR IOL. The patient sample was divided into myopic and hyperopic groups. Monocular uncorrected visual acuity at distance and near (UCVA and UCNVA, respectively and monocular best corrected visual acuity at distance and near (BCVA and BCNVA, respectively were measured before and 6 months postoperatively. Monocular CS function was measured at three different luminance levels (85, 5 and 2.5 cd/m² before and after RLE. Post-implantation results at 6 months were compared with those found before surgery. RESULTS: Our results revealed that patients in both groups obtained good UCVA and BCVA after RLE at distance and near vision in relation to pre-surgery values. No statistically significant differences were found between the values of CS pre and post-RLE at distance and near, at any lighting condition and spatial frequency (p>0.002. CONCLUSIONS: Refractive lens exchange with aspheric AcrySof ReSTOR IOL in myopic and hyperopic population provided good visual function and yield good distance and near CS under photopic and mesopic conditions.

  18. Photosensitizer Adhered to Cell Culture Microplates Induces Phototoxicity in Carcinoma Cells

    Directory of Open Access Journals (Sweden)

    Verena Ziegler

    2013-01-01

    Full Text Available In vitro experiments in plastic receptacles are the basis of characterization of new photosensitizers (PSs for the photodynamic therapy. We recently reported that lipophilic PSs adhere to cell culture microplates in a kinetic-like manner (Engelhardt et al., 2011. In the current study, we examined the interaction and phototoxic effects of the microplate-adhered PS in cancer cells. Therefore, we preloaded microplates with hypericin, Foscan, PVP-hypericin, or aluminum (III phthalocyanine tetrasulfonate chloride (AlPCS4 for 24 hours and measured the PS distribution after addition of A431 human carcinoma cells: following another 24 hours up to 68% of hypericin were detected in the cell fraction. The hydrophilic PVP-hypericin and AlPCS4 also diffused into the cells, but the quantities of PS adherence were considerably lower. Microplate-adhered Foscan appeared not to be redistributed. In contrast to the hydrophilic PSs, the cellular phototoxicity of microplate-adhered lipophilic PS was high, independent of whether the PS (i was pre-loaded onto microplates or (ii added simultaneously with the cells or (iii one day after cell seeding. Based on these results, we suggest testing lipophilic PS dyes for their adherence to microplates. Furthermore, the ability of plastic materials to (reversibly store PSs might represent a new approach for the PS delivery or the development of antimicrobial coatings.

  19. Phototoxic and modulatory effects of natural products from the skin of Rhinella jimi (Stevaux, 2002

    Directory of Open Access Journals (Sweden)

    Samuel V. Brito

    2012-02-01

    Full Text Available The skin of amphibians possesses a large diversity of biologically active compounds that are associated with the natural defenses of these animals against pathogens. Five different extracts and fractions were obtained from the skin of Rhinella jimi: methanol extract (ME, methanol fractions (MF, chloroform extract of methanol extract (CF, aqueous alkaloid fraction (AAF and aqueous non-alkaloid fraction (ANAF. All fractions were evaluated with respect to their antibiotic modifying activity in standard bacterial strains and multiresistant clinical isolates. Antagonism was detected with kanamycin and gentamicin when combined with substances obtained from the skin of R. jimi. Phototoxic activity was observed in the methanol and chlorophorm fractions, as well as the aqueous non-alkaloid fraction. The antagonistic action was apparently associated with the protection afforded by the bacterial populations that inhabit the skin of this amphibian, preventing colonization by pathogenic fungi. The phototoxic activity demonstrated by natural products from the skin of R. jimi showed an interruption of the bacterial growth after UV exposure. This could indicate an antibacterial effect activated by the UV light, opening a path for carrying the attack by pathogenic fungi, causing the disease related with the amphibian decline.

  20. Phototoxicity free quantum dot-based niosome formulation for controlled drug release and its monitoring

    Science.gov (United States)

    Kumar, Sunil; Kang, T. W.; Bala, Suman; Kamboj, Sunil; Jeon, H. C.

    2018-04-01

    A novel niosomes-based system composed of Hypromellose (HPMC) functionalized fluorescent, biocompatible ZnS:Mn quantum dots (QDs), and anti-HIV drug Tenofovir disoproxil fumarate (TDF) was designed. An appropriate ratio of surfactant Sorbitan Monostearate (SPAN-60) and cholesterol was used to obtain an optimal entrapment efficiency. Initially, after observing the successful interaction of HPMC with SPAN-60, the noisome formulation including (QDs + drug) and HPMC-coated QDs was synthesized by a wet chemical route and characterized by X-ray diffraction (XRD), Transmission electron microscope (TEM) and Selected Electron Diffraction (SAED). Secondly, (QDs + drug) loaded niosome formulations were studied by varying the ratio of SPAN-60 and cholesterol. Multiple studies were done to characterize the shape, size, viscosity, colloidal stability, and entrapment efficiency of (QDs + drug) loaded niosomes. Lastly, pH-dependent (QDs + drug) release profiles were studied by a spectroscopic technique considering the pH of the human gastrointestinal region to obtain the formulation stability of (QDs + drug) release from the niosome vesicles. These studies also include pH-dependent photo-stability measurements based on laser-induced multiphoton excitation technique in the Infrared region. The multiphoton time-resolved studies were completed to avoid the UV induced phototoxicity in the drug delivery modules. Current studies on the formulation of niosomes-based (QDs + drug) system laid a foundation to make a complete phototoxicity free system for tracking controlled drug release and its imaging.

  1. Assessing phototoxicity of petroleum using the bivalve Mulinia lateralis and the mysid Mysidopsis bahia

    International Nuclear Information System (INIS)

    Pelletier, M.; Champlin, D.; Burgess, R.; Ho, K.; Kuhn-Hines, A.

    1995-01-01

    One of the major inputs of PAHs in the marine environment is petroleum products. A large and often catastrophic source of petroleum is an oil spill, which releases concentrated quantities of PAHs into the water column. Intermediate molecular weight compounds remain in the water column for a relatively extended length of time. These compounds include phototoxic PAHs such as anthracene, fluoranthene, pyrene, and their substituted derivatives. Assessments of the environmental impact of marine oil spills have not included phototoxicity tests using pelagic larvae of benthic invertebrates. In this study, the photoreactive toxicity of individual PAHs, including anthracene, pyrene, and fluoranthene, were determined using the bivalve, Mulinia lateralis and the mysid, Mysidopsis bahia. Ultraviolet light exposures increased toxicity relative to fluorescent light for both species but a particularly dramatic response was seen using M. lateralis embryos. This species was relatively insensitive when exposed under fluorescent lights, but exhibited up to a 4,000 fold increase in toxicity under ultraviolet lights. Exposures with different types of petroleum (e.g., fuel oil number-sign 2 and crude oil) under fluorescent and ultraviolet light will demonstrate the utility of this bivalve and mysid for assessing oil spill-related acute and sublethal toxicity in the marine environment

  2. Phototoxic Activity and DNA Interactions of Water-Soluble Porphyrins and Their Rhenium(I) Conjugates.

    Science.gov (United States)

    Mion, Giuliana; Gianferrara, Teresa; Bergamo, Alberta; Gasser, Gilles; Pierroz, Vanessa; Rubbiani, Riccardo; Vilar, Ramon; Leczkowska, Anna; Alessio, Enzo

    2015-11-01

    In the search for alternative photosensitizers for use in photodynamic therapy (PDT), herein we describe two new water-soluble porphyrins, a neutral fourfold-symmetric compound and a +3-charged tris-methylpyridinium derivative, in which either four or one [1,4,7]-triazacyclononane (TACN) units are connected to the porphyrin macrocycle through a hydrophilic linker; we also report their corresponding tetracationic Re(I) conjugates. The in vitro (photo)toxic effects of the compounds toward the human cell lines HeLa (cervical cancer), H460M2 (non-small-cell lung carcinoma), and HBL-100 (non-tumorigenic epithelial cells) are reported. Three of the compounds are not cytotoxic in the dark up to 100 μm, and the fourfold-symmetric couple revealed very good phototoxic indexes (PIs). The intracellular localization of all derivatives was studied in HeLa cells by confocal fluorescence microscopy. Although low nuclear localization was observed for some of them, it still prompted us to investigate their capacity to bind both quadruplex and duplex DNA; we observed significant selectivity in the tris-methylpyridinium derivatives for G-quadruplex interactions. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Surgical treatment of hereditary lens subluxations.

    Science.gov (United States)

    Ozdek, Sengul; Sari, Ayca; Bilgihan, Kamil; Akata, Fikret; Hasanreisoglu, Berati

    2002-01-01

    To evaluate the effectiveness and results of pars plana vitreolensectomy approach with transscleral fixation of intraocular lens in hereditary lens subluxations. Fifteen eyes of 9 consecutive patients with a mean age of 12.8+/-6.2 years (6-26 years) with hereditary lens subluxation were operated on and the results were evaluated in a prospective study. Surgery was considered if best spectacle corrected visual acuity (BSCVA) was less than 20/70. All eyes underwent a 2-port pars plana vitreolensectomy and transscleral fixation of an intraocular lens (IOL). The mean follow-up period was 12.6+/-7.5 months (6-22 months). There was no major intraoperative complication. Preoperatively, 8 eyes (53.3%) had a BSCVA of counting fingers (CF) and 7 eyes (46.6%) had a BSCVA of 20/200 to 20/70. Postoperatively, 14 eyes (93.3%) had a BSCVA of 20/50 or better. None of the patients had IOL decentration or intraocular pressure (IOP) increase during the follow-up period. There was a macular hole formation in 1 eye postoperatively. The early results of pars plana vitreolensectomy with IOL implantation using scleral fixation technique had shown that it not only promises a rapid visual rehabilitation but it is also a relatively safe method. More serious complications, however, may occur in the long term.

  4. [Congenital lens subluxation: visual acuity outcomes and intraocular lens postoperative position].

    Science.gov (United States)

    Arraes, Caroline; Endriss, Daniela; Lobato, Francisco; Arraes, João; Ventura, Marcelo

    2010-01-01

    To evaluate the visual acuity outcomes and to investigate the intraocular lens (IOL) and endocapsular ring positions with ultrasound biomicroscopy in 17 eyes of 10 patients with congenital lens subluxation who underwent the same surgical technique, by the same surgeon. The study was performed in the ''Hospital de Olhos de Pernambuco'' and ''Fundação Altino Ventura''. The surgical technique consisted of phacoaspiration with implant of endocapsular ring and intraocular lens with one loop haptic amputated. The age varied from 7 to 22 years. Data on visual acuity (VA) before and after surgery, surgery follow-up period, and complications were analyzed. All patients underwent ultrasound biomicroscopy. The mean follow-up period was 2.8 years. There was a VA improvement in 17 (100%) eyes: in 12 eyes (70.6%) the visual acuity was better than 20/40; 4 (23.5%) ranged from 20/40 to 20/100, and 1 (5.9%) had visual acuity worse than 20/100, however better than the preoperative visual acuity. The posterior capsular opacification occurred in 10 eyes (58.9%). Ultrasound biomicroscopy showed that all IOL were partially decentralized, however without surpassing the pupil border limit. Endocapsular ring position was correct and there was a good capsular support in all cases. The evaluated surgical treatment provided good intraocular lens and endocapsular ring position, with VA improvement Thus, this technique is a viable, effective and safe option for the visual rehabilitation of patients with congenital lens subluxation.

  5. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... new application of artificial intelligence shows whether a patient’s eyes point to high blood pressure or risk ...

  6. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... ask for a prescription. There is no such thing as a "one size fits all" contact lens. ...

  7. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... had not been properly fitted by an eye care professional, the lenses stuck to my eye like ... lenses do not require the same level of care or consideration as a standard contact lens because ...

  8. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her ...

  9. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... Costume Contact Lenses Can Ruin Vision Eye Makeup Safety In fact, it is illegal to sell colored ...

  10. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... with Colored Contact Lenses Julian: Teenager Blinded In One Eye By Non-Prescription Contact Lens Laura: Vision ... Robyn: Blurry Vision and Daily Eye Drops After One Use Facts About Colored Contacts and Halloween Safety ...

  11. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of Service For ...

  12. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... in a pair of colored contact lenses, Laura Butler of Parkersburg, W.Va., had "extreme pain in ... to wear any kind of contact lens. In Butler's case, the lenses caused an infection and left ...

  13. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses ...

  14. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... an impulsive buy from a souvenir shop, but 10 hours after she first put in a pair ... Prescription Contact Lens Laura: Vision Loss After Just 10 Hours Robyn: Blurry Vision and Daily Eye Drops ...

  15. bubble chamber lens

    CERN Multimedia

    Before the days of electronic detectors, visual techniques were used to detect particles, using detectors such as spark chambers and bubble chambers. This plexiglass lens was used to focus the image of tracks so they could be photographed.

  16. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Contact Lens Facts Over-the-Counter Costume Contacts May Contain Chemicals Harmful to Eyes Four Ways Over- ... without a prescription are breaking the law, and may be fined $11,000 per violation. "Many of ...

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not require the same level of care or consideration as a standard contact lens because they can ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ...

  18. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... an ophthalmologist — an eye medical doctor — who will measure each eye and talk to you about proper ...

  19. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... prescription. Follow the contact lens care directions for cleaning, disinfecting, and wearing the lenses. Never share contact ... with Industry Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  20. Viscous froth lens

    Science.gov (United States)

    Green, T. E.; Bramley, A.; Lue, L.; Grassia, P.

    2006-11-01

    Microscale models of foam structure traditionally incorporate a balance between bubble pressures and surface tension forces associated with curvature of bubble films. In particular, models for flowing foam microrheology have assumed this balance is maintained under the action of some externally imposed motion. Recently, however, a dynamic model for foam structure has been proposed, the viscous froth model, which balances the net effect of bubble pressures and surface tension to viscous dissipation forces: this permits the description of fast-flowing foam. This contribution examines the behavior of the viscous froth model when applied to a paradigm problem with a particularly simple geometry: namely, a two-dimensional bubble “lens.” The lens consists of a channel partly filled by a bubble (known as the “lens bubble”) which contacts one channel wall. An additional film (known as the “spanning film”) connects to this bubble spanning the distance from the opposite channel wall. This simple structure can be set in motion and deformed out of equilibrium by applying a pressure across the spanning film: a rich dynamical behavior results. Solutions for the lens structure steadily propagating along the channel can be computed by the viscous froth model. Perturbation solutions are obtained in the limit of a lens structure with weak applied pressures, while numerical solutions are available for higher pressures. These steadily propagating solutions suggest that small lenses move faster than large ones, while both small and large lens bubbles are quite resistant to deformation, at least for weak applied back pressures. As the applied back pressure grows, the structure with the small lens bubble remains relatively stiff, while that with the large lens bubble becomes much more compliant. However, with even further increases in the applied back pressure, a critical pressure appears to exist for which the steady-state structure loses stability and unsteady

  1. Necrotizing nocardial scleritis after combined penetrating keratoplasty and phacoemulsification with intraocular lens implantation: a case report and review of the literature Esclerite necrosante por Nocardia após ceratoplastia penetrante e facoemulsificação com implante de lente intra-ocular: caso clínico e revisão de literatura

    Directory of Open Access Journals (Sweden)

    Jerome Charles Ramos-Esteban

    2007-03-01

    Full Text Available We report the history and clinical presentation of an 88-year-old female with Fuchs dystrophy who developed an acute anterior necrotizing scleritis in her left eye 23 months after an uncomplicated combined penetrating keratoplasty and phacoemulsification with intraocular lens implantation which progressed to slceral perforation with uveal prolapses. The patient underwent a complete systemic work-up for both autoimmune and infectious causes of scleritis. Surgical specimens of the area of scleral perforation were sent for histology and microbiologic studies. Analysis of surgical specimens revealed the presence of culture-proven Nocardia asteroides as a causative agent for the patient's scleral perforation. Results of her systemic autoimmune work-up were not conclusive. Successful treatment with tectonic scleral reinforcement with donor corneal tissue and preserved pericardium, oral and topical trimethoprim-sulfamethoxazole and topical amikacin salvaged the globe and increased vision. The patient's final best-corrected visual acuity sixteen months after her last operation remains 20/70. Prompt surgical intervention with submission of appropriate specimens for pathological diagnosis and microbiology, along with consultation with rheumatologic and infectious disease specialists, are mandatory to minimize visual loss in cases of suspected infectious necrotizing scleritis.Relato de caso de esclerite necrosante aguda, evoluindo para perfuração escleral com prolapso uveal, 23 meses após procedimento de ceratoplastia penetrante e facoemulsificação com implante de lente intra-ocular no olho esquerdo sem intercorrências.A paciente foi submetida à avaliação completa auto-imune para esclerite. Biópsia da área de perfuração escleral foi encaminhada para avaliação patológica e microbiológica. Análise de material cirúrgico revelou presença de cultura proveniente de Nocardia asteroides como agente causal da perfuração escleral. Resultados de

  2. Nano TiO2: an assessment of potential phototoxicity in retinal pigment epithelial cells in vitro.

    Science.gov (United States)

    Nanoparticles often have properties, such as photoactivity, that differ from those of their bulk counterparts. Photoactive materials can become phototoxic by the generation of reactive oxygen species and free-radical oxidative damage to surrounding tissues. The retina is the only...

  3. Novel benzophenone-3 derivatives with promising potential as UV filters: Relationship between structure, photoprotective potential and phototoxicity.

    Science.gov (United States)

    González, María Teresa Páez; Fumagalli, Fernando; Benevenuto, Carolina Gomes; da Silva Emery, Flavio; Gaspar, Lorena Rigo

    2017-04-01

    Benzophenone-3 (BP-3) is a UV filter with absorption at the UVB and UVA wavelengths which has not been extensively studied in experiments involving its absorbing effects and toxicity. We synthetized four BP-3 derivatives and characterized their photoprotective potential by UV absorption and photodegradation, their phototoxicity potential by 3T3 Neutral Red Uptake (3T3 NRU PT) and their photoreactivity by the reactive oxygen species (ROS) assay. The UV absorption, photodegradation, phototoxicity and photoreactivity of the four BP-3 derivatives (BP-3 carbonate, BP-3 carbazole, BP-3 phenylamine and BP-3 methoxy-phenylamine) were evaluated and compared to those of BP-3. Results showed that all derivatives were photostable, except BP-3 carbonate, which did not absorb in the UVA range. BP-3 phenylamine and BP-3 methoxy-phenylamine were considered non-phototoxic and weakly photoreactive in the ROS assay, while the carbazole derivative was considered phototoxic and non-photoreactive due to its rigid structure. The UV spectra of BP-3 carbonate, BP-3 phenylamine and BP-3 methoxy-phenylamine showed the influence of hydrogen bonding on their UV absorption. Based on these results, we concluded that BP-3 phenylamine and BP-3 methoxy-phenylamine could be promising UVA filters. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Phototoxicity of TiO2 Nanoparticles to Two Aquatic Species: Daphnia magna and Zebrafish (Danio rerio) Embryo

    Science.gov (United States)

    Ecotoxicological studies on TiO2 nanoparticles (nano-TiO2) are expanding rapidly due to their widespread use in both industrial and consumer products. However, few studies have focused on their potential phototoxicity related to the photocatalytic property of the material. In thi...

  5. Assessment of phototoxicity, skin irritation, and sensitization potential of polystyrene and TiO2 nanoparticles

    International Nuclear Information System (INIS)

    Park, Yoon-Hee; Jeong, Sang Hoon; Yi, Sang Min; Choi, Byeong Hyeok; Son, Sang Wook; Kim, Yu-Ri; Kim, In-Kyoung; Kim, Meyoung-Kon

    2011-01-01

    The human skin equivalent model (HSEM) is well known as an attractive alternative model for evaluation of dermal toxicity. However, only limited data are available on the usefulness of an HSEM for nanotoxicity testing. This study was designed to investigate cutaneous toxicity of polystyrene and TiO 2 nanoparticles using cultured keratinocytes, an HSEM, and an animal model. In addition, we also evaluated the skin sensitization potential of nanoparticles using a local lymph node assay with incorporation of BrdU. Findings from the present study indicate that polystyrene and TiO 2 nanoparticles do not induce phototoxicity, acute cutaneous irritation, or skin sensitization. Results from evaluation of the HSEMs correspond well with those from animal models. Our findings suggest that the HSEM might be a useful alternative model for evaluation of dermal nanotoxicity.

  6. Assessment of phototoxicity, skin irritation, and sensitization potential of polystyrene and TiO2 nanoparticles

    Science.gov (United States)

    Park, Yoon-Hee; Jeong, Sang Hoon; Yi, Sang Min; Hyeok Choi, Byeong; Kim, Yu-Ri; Kim, In-Kyoung; Kim, Meyoung-Kon; Son, Sang Wook

    2011-07-01

    The human skin equivalent model (HSEM) is well known as an attractive alternative model for evaluation of dermal toxicity. However, only limited data are available on the usefulness of an HSEM for nanotoxicity testing. This study was designed to investigate cutaneous toxicity of polystyrene and TiO2 nanoparticles using cultured keratinocytes, an HSEM, and an animal model. In addition, we also evaluated the skin sensitization potential of nanoparticles using a local lymph node assay with incorporation of BrdU. Findings from the present study indicate that polystyrene and TiO2 nanoparticles do not induce phototoxicity, acute cutaneous irritation, or skin sensitization. Results from evaluation of the HSEMs correspond well with those from animal models. Our findings suggest that the HSEM might be a useful alternative model for evaluation of dermal nanotoxicity.

  7. Penile Implants

    Science.gov (United States)

    ... the discussion with your doctor. Types of penile implants There are two main types of penile implants: ... might help reduce the risk of infection. Comparing implant types When choosing which type of penile implant ...

  8. A catoptric lens

    International Nuclear Information System (INIS)

    Rambauske, W.R.

    1973-01-01

    The invention relates to a catoptric lens for combining energies transmitted by several sources such as lasers; said lens comprising mirrors, the reflective surfaces of which have their focuses spaced from a common axis of symmetry. By means of these reflecting surfaces, which are generated by the nutation of portions of quadratic conics about the axis of symmetry, it is possible to focus the energy emmited by several lasers at the focus of the exit-mirror reflecting surface. This can be applied to thermonuclear fusion [fr

  9. Scleral suspension pars-plana lensectomy for ectopia lentis followed by suture fixation of intraocular lens

    Directory of Open Access Journals (Sweden)

    Mitra Sandip

    2001-01-01

    Full Text Available Purpose: To describe a simple technique of scleral suspension-pars plana lensectomy (SS-PPL in acquired and congenital ectopia lentis and scleral fixation of intraocular lens (IOL. Materials and Methods: Twenty eyes of 16 patients (12 unilateral and 4 bilateral cases of "essential familial lens subluxation" aged 10-40 years (mean 25 years underwent SS-PPL with implantation of scleral fixated IOL. Indications for surgery were best-corrected visual acuity <6/18, bisection of pupil by the lens, and lens-induced glaucoma. Prerequisites for SS-PPL were, visibility of part of the lens in the pupillary area and soft lens. Results: Postoperative visual acuity ranged from 6/6 - 6/36. Lens tilt in 3 cases(15% and small decentration in 2 cases(10% were seen; however these did not seriously compromise the visual result. Scant vitreous bleeding on the first postoperative day was seen in 3 cases (15%. Conclusion: The advantages of the scleral suspension of subluxated lens prior to lensectomy include stabilization; it allows proper viewing of the lens, avoids injury to the iris and cliary body during lensectomy and reduces the possibility of dislocation of the lens.

  10. Quadrupole magnetic lens

    International Nuclear Information System (INIS)

    Piskunov, V.A.

    1981-01-01

    The following connection of windings of electromagnet is suggested for simplification of the design of qUadrupole magnetic lens intended for use in radiotechnical and electron-optical devices. The mentioned windings are connected with each other by a bridge scheme and the variable resistors are switched in its diagonals in the lens containing four electromagnet with windings connected with two variable resistors the mobile contacts of which are connected with a direct current source. Current redistribution between left windings and right windings takes place at shift of mobile contact of variable resistor, and current redistribution between upper and low coils of electromagnets takes place at shifting mobile contact of the other variable resistor. In this case smooth and independent electron-optical misalignment of lens by two mutually perpendicular directions proceeds. Use of the given design of the lens in the oscillograph permits to use printing assembly for alignment plate and to reduce the number of connections at the expense of decreasing the number of resistors

  11. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... prescription. There is no such thing as a "one size fits all" contact lens. Lenses that are not properly fitted may scratch the eye or cause blood vessels to grow into the cornea. Even if you have perfect vision, you need to get an eye exam and a prescription ...

  12. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Ophthalmologist Patient Stories Español Eye Health / News Halloween Hazard: The Hidden Dangers of Buying Decorative Contact Lenses ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ...

  13. MISSING: BUBBLE CHAMBER LENS

    CERN Multimedia

    2001-01-01

    Would the person who borrowed the large bubble chamber lens from the Microcosm workshops on the ISR please return it. This is a much used piece from our object archives. If anybody has any information about the whereabouts of this object, please contact Emma.Sanders@cern.ch Thank you

  14. The Lens of Chemistry

    Science.gov (United States)

    Thalos, Mariam

    2013-01-01

    Chemistry possesses a distinctive theoretical lens--a distinctive set of theoretical concerns regarding the dynamics and transformations of a perplexing variety of organic and nonorganic substances--to which it must be faithful. Even if it is true that chemical facts bear a special (reductive) relationship to physical facts, nonetheless it will…

  15. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her with a corneal ... A recent article from U.S. News and World Report explains what ophthalmologists are and how they can ...

  16. bubble chamber lens

    CERN Multimedia

    Was used in a PS experiment. Before the days of electronic detectors, visual techniques were used to detect particles, using detectors such as spark chambers and bubble chambers. This plexiglass lens was used to focus the image of tracks so they could be photographed.

  17. Thermal Lens Microscope

    Science.gov (United States)

    Uchiyama, Kenji; Hibara, Akihide; Kimura, Hiroko; Sawada, Tsuguo; Kitamori, Takehiko

    2000-09-01

    We developed a novel laser microscope based on the thermal lens effect induced by a coaxial beam comprised of excitation and probe beams. The signal generation mechanism was confirmed to be an authentic thermal lens effect from the measurement of signal and phase dependences on optical configurations between the sample and the probe beam focus, and therefore, the thermal lens effect theory could be applied. Two-point spatial resolution was determined by the spot size of the excitation beam, not by the thermal diffusion length. Sensitivity was quite high, and the detection ability, evaluated using a submicron microparticle containing dye molecules, was 0.8 zmol/μm2, hence a distribution image of trace chemical species could be obtained quantitatively. In addition, analytes are not restricted to fluorescent species, therefore, the thermal lens microscope is a promising analytical microscope. A two-dimensional image of a histamine molecule distribution, which was produced in mast cells at the femtomole level in a human nasal mucous polyp, was obtained.

  18. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... an Ophthalmologist Patient Stories Español Eye Health / News Halloween Hazard: The Hidden Dangers of Buying Decorative Contact ... After One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter ...

  19. Clinical survey of lens care in contact lens patients.

    Science.gov (United States)

    Ky, W; Scherick, K; Stenson, S

    1998-10-01

    Overall, contact lenses provide a safe and effective modality for vision correction. However, problems do occasionally arise. Up to 80% of contact lens complications can be traced to poor patient compliance with recommended lens care guidelines. We conducted a survey to evaluate the level of patient compliance in specific areas of lens care and maintenance and to assess patient knowledge of basic contact lens information. Patients were asked to complete an anonymous 15 question survey that focused on lens care--specifically the use of contact lens cleaners, methods of disinfection, enzyme treatments, use of rewetting drops, and the frequency of follow-up exams. In addition, the survey included six true/false questions relating to contact lens care and safety. There were a total of 103 participants in the study. Approximately 24% of patients stated they never cleaned their lenses prior to disinfection, and 5% used saline solutions as their primary mode of disinfection. A sizable portion of those surveyed (43% of soft lens wearers and 71% of rigid gas permeable lens wearers) either never used enzyme cleaners or used them less than once a month. Seventy percent of patients either never used rewetting drops or used them less than once a day. Twenty-nine percent of patients consulted their eye care professionals every 2 years and 6% less often than every two years. Six questions assessed patient knowledge of contact lens care safety. Of a possible six out of six correct answers, the mean number of correct responses was 3.74. A sizable proportion of contact lens wearers do not adequately adhere to recommended contact lens care, and many have an inadequate understanding of contact lens care guidelines. Therefore, it is important that practitioners place more emphasis on patient education at the time of initial contact lens fitting and reinforce such instruction during follow-up visits.

  20. Dual role of melanins and melanin precursors as photoprotective and phototoxic agents: inhibition of ultraviolet radiation-induced lipid peroxidation

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz, S.; Jimbow, K. [Alberta Univ., Edmonton, AB (Canada). Dept. of Dermatology and Cutaneous Sciences; Thomas, P.D.; Poznansky, M.J. [Alberta Univ., Edmonton, AB (Canada). Dept. of Physiology; Allen, T.M. [Alberta Univ., Edmonton, AB (Canada). Dept. of Pharmacology

    1995-06-01

    Ultraviolet radiation (UVR) is one of the risk factors for skin cancer and the main inducer of melanin pigmentation, the major protective mechanism of mammalian skin against radiation damage. The melanin pigments, eumelanin and pheomelanin, are likely to be important in protection against UVR, but their precursors are generally considered as phototoxic. The available data suggest DNA damage as the mechanism of phototoxicity. However, the effect of melanin precursors on membrane damage through lipid peroxidation, another important and probably more relevant (from the point-of-view of the melanosomal confinement of these molecules) mechanism of phototoxicity, is not known. As a model system for UVR-melanin-membrane interactions, we irradiated liposomes in the presence of eumelanin, pheomelanin and two of their major precursors, 5,6-dihydroxyindole (DHI) and 5-S-cysteinyldopa (SCD). The presence of the two melanin precursors substantially reduced the formation of lipid peroxidation products resulting from UVR exposure. The antioxidant activity of the melanin precursors was diminished under strong prooxidant conditions (presence of Fe{sub 3+}). These results suggest that melanin precursors may have an important role in the protection of skin against the harmful effects of UVR including photocarcinogenesis. (Author).

  1. Evaluation of antimicrobial, antioxidant and phototoxic activities of extracts and isolated compounds from Stachytarpheta cayennensis (Rich. Vahl, Verbenaceae

    Directory of Open Access Journals (Sweden)

    Pierre André De Souza

    2010-11-01

    Full Text Available Stachytarpheta cayennensis (Rich. Vahl, Verbenaceae, plant extract, is a Brazilian medicinal plant externally used in folk medicine for purulent ulcers, skin lesions and internally for inflammations, fever, renal disorders and atherosclerosis. S. cayennesis was studied to identify potential bioactive compounds that may justify their therapeutic use against skin lesions and atherosclerosis. The antioxidant, antimicrobial and phototoxicity capacities of the crude ethanolic extract, fractions and isolated compounds from roots of S. cayennesis were evaluated through in vivo and in vitro tests. Strains of Saccharomyces cerevisiae, an eukaryotic cell model, were used to assess both the phototoxicity and the capacity to protect against the lethal oxidative stress caused by menadione and hydrogen peroxide. The extract, fractions and the two major isolated compounds, verbascoside and betulinic acid, of S. cayennensis were able to increase the tolerance and decrease the lipid peroxidation of S. cerevisiae to reactive oxygen species (ROS. The antioxidant activity was also evaluated by scavenging of 2,2-diphenyl-1-picrylhydrazyl (DPPH•. Verbascoside exhibited a moderate antimicrobial activity against Streptococcus pyogenes, S.epidermidis and Staphylococcus aureus. Neither the ethanolic extract nor fractions showed phototoxicity, indicating that the S. cayennensis extract is safe for use in the treatment of skin lesions and as an active cosmetic ingredient.

  2. Scleral fixation of a single-piece multifocal intraocular lens.

    Science.gov (United States)

    Can, Ertugrul; Basaran, M Resat; Gül, Adem

    2013-01-01

    We describe an ab interno technique for injector implantation of a one-piece multifocal intraocular lens (IOL). Transscleral fixation of multifocal posterior chamber IOL implantation using an injector with ab interno technique was performed in an eye of a 9-year-old girl who had undergone pars plana lensectomy 2 years before for bilateral lens subluxation with unknown etiology. No major complications were encountered during a 3-month follow-up of the patient and excellent centration was observed during the follow-up period. Her preoperative best spectacle-corrected distance visual acuity of 20/32 improved to uncorrected distance visual acuity of 20/25. Closed-loop design of IOL served the function of eyelets and position of the IOL was provided using only a 2-point fixation. Intraoperative position adjustment of the IOL provided an excellent centralization of multifocal IOL.

  3. [Correct contact lens hygiene].

    Science.gov (United States)

    Blümle, S; Kaercher, T; Khaireddin, R

    2013-06-01

    Although contact lenses have long been established in ophthalmology, practical aspects of handling contact lenses is becoming increasingly less important in the clinical training as specialist for ophthalmology. Simultaneously, for many reasons injuries due to wearing contact lenses are increasing. In order to correct this discrepancy, information on contact lenses and practical experience with them must be substantially increased from a medical perspective. This review article deals with the most important aspects for prevention of complications, i.e. contact lens hygiene.

  4. Bilateral spontaneous dislocation of posterior chamber intraocular lens in a patient with gyrate atrophy

    Directory of Open Access Journals (Sweden)

    Michael Kinori

    2012-01-01

    Full Text Available We report a patient with gyrate atrophy, a rare metabolic disease, who had bilateral late spontaneous posterior dislocation of in-the-bag posterior chamber intraocular lens (PCIOL. He underwent pars plana vitrectomy, PCIOL retrieval and anterior chamber intraocular lens implantation in both eyes. This report may imply that patients with gyrate atrophy are at risk for spontaneous dislocation of intraocular lenses.

  5. Intraocular lens subluxation in a patient with facial atopic dermatitis.

    Science.gov (United States)

    Yamazaki, S; Nakamura, K; Kurosaka, D

    2001-02-01

    A 66-year-old Japanese man presented with subluxation of a posterior chamber intraocular lens (IOL) caused by a rupture of part of Zinn's zonule but no retinal break 2 years after phacoemulsification with IOL implantation. He had a history of atopic dermatitis since infancy. This case presents a rare ocular complication of scratching and rubbing the face and eyelids because of itching related to atopic dermatitis.

  6. Evaluation of Artisan aphakic intraocular lens in cases of pediatric aphakia with insufficient capsular support.

    Science.gov (United States)

    Gawdat, Ghada I; Taher, Sameh G; Salama, Marwa M; Ali, Adel A

    2015-06-01

    To evaluate the visual outcomes and complications after Artisan iris-claw lens implantation in aphakic children with insufficient capsular support. In this prospective, interventional noncontrolled study, aphakic eyes of consecutive patients >2 years of age with insufficient capsular support who underwent Artisan intraocular lens (IOL) implantation between June 2011 and December 2012 were followed for 1 year. Patients with anterior chamber depth IOL were included, 18 eyes with subluxated lens and 7 following trauma. The mean preoperative logMAR best-corrected visual acuity for traumatic aphakic patients was 0.95 ± 0.36; for patients with subluxation, 0.7 ± 0.26. Values improved at 1 year to 0.38 ± 0.15 (P IOL implantation for pediatric aphakia achieved a good visual outcome. Copyright © 2015 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  7. Conical diffraction illumination opens the way for low phototoxicity super-resolution imaging

    Science.gov (United States)

    Caron, Julien; Fallet, Clément; Tinevez, Jean-Yves; Moisan, Lionel; Braitbart, L Philippe (Ori); Sirat, Gabriel Y; Shorte, Spencer L

    2014-01-01

    We present a new technology for super-resolution fluorescence imaging, based on conical diffraction. Conical diffraction is a linear, singular phenomenon, taking place when a laser beam is diffracted through a biaxial crystal. We use conical diffraction in a thin biaxial crystal to generate illumination patterns that are more compact than the classical Gaussian beam, and use them to generate a super-resolution imaging modality. While there already exist several super-resolution modalities, our technology (biaxial super-resolution: BSR) is distinguished by the unique combination of several performance features. Using BSR super-resolution data are achieved using low light illumination significantly less than required for classical confocal imaging, which makes BSR ideal for live-cell, long-term time-lapse super-resolution imaging. Furthermore, no specific sample preparation is required, and any fluorophore can be used. Perhaps most exciting, improved resolution BSR-imaging resolution enhancement can be achieved with any type of objective no matter the magnification, numerical aperture, working distance, or the absence or presence of immersion medium. In this article, we present the first implementation of BSR modality on a commercial confocal microscope. We acquire and analyze validation data, showing high quality super-resolved images of biological objects, and demonstrate the wide applicability of the technology. We report live-cell super-resolution imaging over a long period, and show that the light dose required for super-resolution imaging is far below the threshold likely to generate phototoxicity. PMID:25482642

  8. Kinetics of phototoxicity of Fischer's medium for L5178Y leukemic cells

    International Nuclear Information System (INIS)

    Griffin, F.M.; Ashland, G.; Capizzi, R.L.

    1981-01-01

    The uncontrolled exposure of Fischer's medium to cool white fluorescent (CWF) light or other sources emitting near-ultraviolet or visible light absorbance by riboflavin is a crucial random variable in experiments which utilize L5178Y cells and this medium. The radiation effects of CWF light result in the rapid development of toxic photoproducts in the medium which are cytostatic at lower doses of radiation and cytotoxic at higher doses. After a 24-hr suspension in medium irradiated for 3 or 48 hr, the cloning efficiencies of cells subsequently plated in light-protected medium were 87 and 3%, respectively. The corresponding near-ultraviolet doses for these periods of exposure to CWF light were 0.22 x 10(4) for a 3-hr exposure and 3.47 x 10(4) J/sq m for a 48-hr exposure. Cells incubated in lightly irradiated medium resumed growth at nearly normal rates following a 24- to 48-hr period in which no increase in cell numbers occurred. Exposure of medium containing riboflavin, but not tryptophan or tyrosine, to CWF light also produces toxic medium. Tryptophan enhances riboflavin-induced phototoxicity, whereas tyrosine diminishes this effect. As photosusceptibility of this system is very high, Fischer's medium must be fully protected from all sources of light absorbable by riboflavin

  9. Possible mechanism of psoralen phototoxicity not involving direct interaction with DNA

    Energy Technology Data Exchange (ETDEWEB)

    Laskin, J.D.; Lee, E.; Yurkow, E.J.; Laskin, D.L.; Gallo, M.A.

    1985-09-01

    Psoralens in combination with ultraviolet light (UVA; 320-400 nm) are used in the photochemical treatment of a variety of skin diseases including vitiligo, a skin depigmentational disorder, and psoriasis, a disease of accelerated epidermal cell proliferation. Although it is generally assumed that the major site of action of the psoralens is DNA, the authors have obtained evidence that another site may be the primary target for these compounds. They have identified specific, saturable, high-affinity binding sites for 8-methoxypsoralen on HeLa cells and have detected specific binding of 8-methoxypsoralen to four other human cell lines and five mouse cell lines. In HeLa cells, specific binding is reversible and independent of the ability of the compound to intercalate into DNA. In addition, binding sites become covalently modified by the psoralen after UVA exposure. Specific binding of 8-(methyoxy-/sup 3/H)methoxypsoralen constitutes 79% of the label bound to the cells. Scatchard analysis indicated two classes of psoralen binding sites. Based on these findings, the authors hypothesize that specific binding sites for psoralens on mammalian cells mediate, at least in part, psoralen-induced phototoxicity.

  10. NGF protects corneal, retinal, and cutaneous tissues/cells from phototoxic effect of UV exposure.

    Science.gov (United States)

    Rocco, Maria Luisa; Balzamino, Bijorn Omar; Aloe, Luigi; Micera, Alessandra

    2018-04-01

    Based on evidence that nerve growth factor (NGF) exerts healing action on damaged corneal, retinal, and cutaneous tissues, the present study sought to assess whether topical NGF application can prevent and/or protect epithelial cells from deleterious effects of ultraviolet (UV) radiation. Eyes from 40 young-adult Sprague Dawley rats and cutaneous tissues from 36 adult nude mice were exposed to UVA/B lamp for 60 min, either alone or in the presence of murine NGF. Corneal, retinal, and cutaneous tissues were sampled/processed for morphological, immunohistochemical, and biomolecular analysis, and results were compared statistically. UV exposure affected both biochemical and molecular expression of NGF and trkA NGFR in corneal, retinal, and cutaneous tissues while UV exposure coupled to NGF treatment enhanced NGF and trkA NGFR expression as well as reduced cell death. Overall, the findings of this in vivo/ex vivo study show the NGF ability to reduce the potential UV damage. Although the mechanism underneath this effect needs further investigation, these observations prospect the development of a pharmacological NGF-based therapy devoted to maintain cell function when exposed to phototoxic UV radiation.

  11. Prolonging contact lens wear and making contact lens wear safer.

    Science.gov (United States)

    Foulks, Gary N

    2006-02-01

    To summarize the present status of safety and efficacy of contact lens wear. Literature review. Ovid Medline searches were performed on records from 1966 through 2005 using keywords: keratitis, contact lens complications, extended-wear contact lenses, and silicone-hydrogel contact lenses. Patients desire comfort, clarity of vision, and prolonged contact lens wear when contact lenses are used to correct refractive error. Practitioners desire patient satisfaction but also require maintenance of the integrity of the eye and no complications that jeopardize vision or health of the eye. Improvements in the oxygen permeability of the contact lens materials, design of the contact lens and its surface, and solutions for the maintenance of the lens have reduced but not eliminated the risks of infection, inflammation, and conjunctival papillary reaction associated with contact lens wear. The lessons of past and recent history suggest that patient education and practitioner participation in the management of contact lens wear continue to be critical factors for patient satisfaction and safety in the extended wear of contact lenses. The availability of highly oxygen permeable contact lenses has increased the tolerance and safety of extended contact lens wear, but patient instruction and education in proper use and care of lenses is required and caution is advised.

  12. Clinical observation of four-fixable intraocular lens suspensory

    Directory of Open Access Journals (Sweden)

    Yu-Ming Teng

    2015-06-01

    Full Text Available AIM: To discuss the four-fixable intraocular lens(IOLsuspensory in the absence of capsular intraocular lens implantation, suspensory ligament rupture caused by congenital dislocation of the lens, traumatic cataract and posterior capsular rupture without capsular support, which need to line hanging IOL for intraoperative clinical observation.METHODS: The 31 cases(32 eyeswho were accepted the four-fixable IOL suspensory from May 2012 to May 2014 in our hospital were retrospectively analyzed. The postoperative visual acuity, corneal astigmatism, intraoperative and postoperative complications were comprehensively analyzed.RESULTS: Patients were followed up 6mo~1a, corrected visual acuity >0.5(12 eyes, 38%, 0.1~0.5(18 eyes, 56%, and CONCLUSION: It is designed to support non-capsular IOL implantation and design, and the concept of changing the past presence of suspended dislocated IOL implantation surgery, positional deviation and, sutures and other complications split the incidence is greatly reduced. It is consistent with the physiological characteristics of the human eye, and it is the IOL surgical sling best stability, intraoperative and postoperative complications, the best visual acuity and corneal astigmatism minimal surgical approachat least, and the four-point suspension suture fixation of IOL is designed to obtain a practical transformation of Chinese patent.

  13. A case of Alagille syndrome complicated by intraocular lens subluxation and rhegmatogenous retinal detachment

    Science.gov (United States)

    Fukumoto, Masanori; Ikeda, Tsunehiko; Sugiyama, Tetsuya; Ueki, Mari; Sato, Takaki; Ishizaki, Eisuke

    2013-01-01

    This case report describes a case of Alagille syndrome with developing intraocular lens subluxation and rhegmatogenous retinal detachment 4 years after cataract surgery. A 15-year-old female patient with Alagille syndrome-associated cataracts in both eyes underwent phacoemulsification aspiration and intraocular lens implantation. Four years postoperative, intraocular lens subluxation developed in her left eye. For treatment, extraction of the dislocated intraocular lens, anterior vitrectomy, and intraocular lens fixation was performed. Three weeks later, the patient developed rhegmatogenous retinal detachment, which was well-treated by pars plana vitrectomy. Cataract surgery needs to be performed carefully in patients with Alagille syndrome due to the weakness of the zonule of Zinn. Careful postoperative observation is necessary for patients with Alagille syndrome who have undergone intraocular surgery in order to facilitate early detection of a possible rhegmatogenous retinal detachment. PMID:23898221

  14. Surgical Management of a Patient with Anterior Megalophthalmos, Lens Subluxation, and a High Risk of Retinal Detachment

    Directory of Open Access Journals (Sweden)

    María Carmen Guixeres Esteve

    2017-01-01

    Full Text Available The early development of lens opacities and lens subluxation are the most common causes of vision loss in patients with anterior megalophthalmos (AM. Cataract surgery in such patients is challenging, however, because of anatomical abnormalities. Intraocular lens dislocation is the most common postoperative complication. Patients with AM also seem to be affected by a type of vitreoretinopathy that predisposes them to retinal detachment. We here present the case of a 36-year-old man with bilateral AM misdiagnosed as simple megalocornea. He had a history of amaurosis in the right eye due to retinal detachment. He presented with vision loss in the left eye due to lens subluxation. Following the removal of the subluxated lens, it was deemed necessary to perform a vitrectomy in order to prevent retinal detachment. Seven months after surgery, an Artisan® Aphakia iris-claw lens was implanted in the anterior chamber. Fifteen months of follow-up data are provided.

  15. Resistance force for intraocular lens insertion through lens cartridges and syringe-type injectors.

    Science.gov (United States)

    Usui, Masahiko; Tanaka, Takao

    2015-08-01

    To measure and compare the resistance force for intraocular lens (IOL) insertion using 5 syringe-type injector systems. Tokyo Medical University and laboratory in Kowa Co., Tokyo, Japan. Experimental study. Intraocular lenses were inserted into the lens capsular bag of porcine eyes after phacoemulsification using 5 implantation systems (Groups A, B, C, D, and E). For each system, the resistance force for IOL insertion to the lens capsular bag of porcine eyes was measured using an automated force gauge system. For control, the resistance force for IOL delivery into a plastic dish was measured. Changes in the resistance force and its curve and maximum value were evaluated. The mean total area under the curve (AUC) was compared. Data were statistically analyzed. For all groups, the mean resistance forces were 17.2, 6.3, 4.2, 20.7, and 2.3 newtons (N), respectively, in porcine eyes, and 14.4, 5.8, 4.5, 12.6, and 2.2 N in controls. The mean sizes of the total AUC were 43 371, 8465, 6771, 30 306, and 2334 pixels in porcine eyes and 40 940, 7080, 6876, 20 710, and 2215 pixels in controls; the correlation coefficients between the resistance forces and the sizes of the total area were 0.576, 0.113, 0.346, 0.726, and 0.933 in porcine eyes and 0.707, 0.557, 0.914, 0.951, and 0.893 in controls. Resistance force and its curve were clarified in 5 IOL implantation systems. Appropriate IOL and injector selection may be achieved after clarifying resistance force and its waveform during IOL insertion. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015. Published by Elsevier Inc.

  16. Evaluation of dicloran phototoxicity using primary cardiomyocyte culture from Crassostrea virginica.

    Science.gov (United States)

    Xu, Wei; Vebrosky, Emily N; Richards, Mackenzie L; Armbrust, Kevin L

    2018-02-09

    Dicloran is a commonly used fungicide throughout the Southern and Western United States. Runoff of dicloran from agriculture systems to nearby waterbodies can accumulate in the organisms that inhabit those areas. Although severe damage of dicloran to ecological systems has not been reported, its toxicity has been modified by photodegradation. The objective of this study is to assess the changes of dicloran toxicities during photo exposure using a reliable in vitro biological model. In the present investigation, the photodegradation of dicloran in vitro showed over 90% of dicloran was degraded within 24h of UV exposure in water. Two major intermediate degradation products, 2-chloro-1,4-benzoquinone (CBQ) and 1,4-benzoquinone (BQ), were detected upon UV exposure of dicloran; however, they were rapidly degraded via photolysis. To estimate the impact of the phototoxicity of dicloran to aquatic organisms, we developed an in vitro cell culture system using the C. virginica cardiomyoctes (CvCMs) which were isolated from heart tissues and formed beating cell clusters. The CvCM clusters were treated with irradiated dicloran or the two intermediate standards, CBQ and BQ, and they showed up to 41% decrease in beating rates compared to control cell clusters. Expression levels of selected genes: def, hsp70, and cam, were upregulated in response to stimulations of UV irradiated dicloran and the two standard intermediates. The four-hour irradiated dicloran also resulted in more significant inhibition in the proliferation and small cardioactive peptide β production of CvCMs than other treatment. Tested solutions of photolyzed dicloran showed elevated toxicities opposed to the standard intermediates, CBQ and BQ, suggesting additive toxicity of these dicloran products or toxicity due to other unidentified degradation products. Results of this study supported our hypothesis that the degradation of dicloran caused by photo irradiation results in an elevated toxicity which can be

  17. Small-Gauge Pars Plana Vitrectomy for the Management of Symptomatic Posterior Vitreous Detachment after Phacoemulsification and Multifocal Intraocular Lens Implantation: A Pilot Study from the Pan-American Collaborative Retina Study Group

    Science.gov (United States)

    Navarro, Rodrigo M.; Machado, Leonardo M.; Maia, Ossires; Wu, Lihteh; Farah, Michel E.; Magalhaes, Octaviano; Arevalo, J. Fernando; Maia, Mauricio

    2015-01-01

    Purpose. To determine the efficacy of 23-gauge pars plana vitrectomy (PPV) for symptomatic posterior vitreous detachment (PVD) on visual acuity (VA) and quality after multifocal intraocular lenses (IOLs). Methods. In this prospective case series, patients who developed symptomatic PVD and were not satisfied with visual quality due to floaters and halos after multifocal IOL implantation underwent PPV. Examinations included LogMAR uncorrected visual acuity (UCVA), intraocular pressure, biomicroscopy, and indirect ophthalmoscopy at baseline and 1, 7, 30, and 180 days postoperatively. Ultrasonography and aberrometry were performed. The Visual Functioning Questionnaire 25 (VFQ-25) was administered preoperatively and at 30 days postoperatively. Both the postoperative UCVA and questionnaire results were compared to preoperative findings using the Wilcoxon test. Results. Sixteen eyes of 8 patients were included. VA significantly improved from 0.17 to 0.09 postoperatively (P = 0.017). All patients reported improvement of halos, glare, and floaters. VFQ-25 scores significantly improved in general vision (P = 0.023), near activities (P = 0.043), distance activities (P = 0.041), mental health (P = 0.011), role difficulties (P = 0.042), and driving (P = 0.016). Conclusion. PPV may increase UCVA and quality of vision in patients with bilateral multifocal IOLs and symptomatic PVD. Larger studies are advised. PMID:26504590

  18. Broad-spectrum sunscreens prevent the secretion of proinflammatory cytokines in human keratinocytes exposed to ultraviolet A and phototoxic lomefloxacin

    International Nuclear Information System (INIS)

    Reinhardt, P.; Cybulski, M.; Miller, S.M.; Ferrarotto, C.; Wilkins, R.; Deslauriers, Y.

    2006-01-01

    The combination of phototoxic drugs and ultraviolet (UV) radiation can trigger the release of proinflammatory cytokines. The present study measured the ability of sunscreens to prevent cytokine secretion in human keratinocytes following cotreatment of these cells with a known photoreactive drug and UVA. Keratinocytes were treated for 1 h with increasing concentrations of lomefloxacin (LOM) or norfloxacin (NOR), exposed to 15 J/cm 2 UVA, and incubated for 24 h. NOR, owing to the absence of a fluorine atom in position 8, was non-phototoxic and used as a negative control. Cell viability and the release of 3 cytokines were assessed, namely interleukin-1α (IL-1α), interleukin-6 (IL-6), and tumour necrosis factor-α (TNF-α). The measurement of these cytokines may be a useful tool for detecting photoreactive compounds. To measure their ability to prevent cytokine secretion, various sunscreens were inserted between the UVA source and the cells. Treatment with NOR, NOR plus UVA, or LOM had no effect on the cells. LOM plus UVA, however, had an effect on cell viability and on cytokine secretion. IL-1α levels increased with LOM concentration. The release of TNF-α and IL-6 followed the same pattern at lower concentrations of LOM but peaked at 15 μmol/L and decreased at higher concentrations. Sunscreens protected the cells from the effects of LOM plus UVA, as cell viability and levels of cytokines remained the same as in the control cells. In conclusion, the application of broad-spectrum sunscreen by individuals exposed to UVA radiation may prevent phototoxic reactions initiated by drugs such as LOM. (author)

  19. Compliance among soft contact lens wearers.

    OpenAIRE

    Kuzman, Tomislav; Barišić Kutija, Marija; Masnec, Sanja; Jandroković, Sonja; Mrazovac, Danijela; Jurišić, Darija; Škegro, Ivan; Kalauz, Miro; Kordić, Rajko

    2014-01-01

    Contact lens compliance is proven to be crucial for preventing lens wear-related complications because of the interdependence of the steps in lens care regime and their influence on lens system microbial contamination. Awareness of the patients' lens handling compliance as well as correct recognition of non-compliant behaviours is the basis for creating more targeted strategies for patient education. The aim of this study was to investigate compliance among soft contact lens (SCL) wearers in ...

  20. Panoramic lens applications revisited

    Science.gov (United States)

    Thibault, Simon

    2008-04-01

    During the last few years, innovative optical design strategies to generate and control image mapping have been successful in producing high-resolution digital imagers and projectors. This new generation of panoramic lenses includes catadioptric panoramic lenses, panoramic annular lenses, visible/IR fisheye lenses, anamorphic wide-angle attachments, and visible/IR panomorph lenses. Given that a wide-angle lens images a large field of view on a limited number of pixels, a systematic pixel-to-angle mapping will help the efficient use of each pixel in the field of view. In this paper, we present several modern applications of these modern types of hemispheric lenses. Recently, surveillance and security applications have been proposed and published in Security and Defence symposium. However, modern hemispheric lens can be used in many other fields. A panoramic imaging sensor contributes most to the perception of the world. Panoramic lenses are now ready to be deployed in many optical solutions. Covered applications include, but are not limited to medical imaging (endoscope, rigiscope, fiberscope...), remote sensing (pipe inspection, crime scene investigation, archeology...), multimedia (hemispheric projector, panoramic image...). Modern panoramic technologies allow simple and efficient digital image processing and the use of standard image analysis features (motion estimation, segmentation, object tracking, pattern recognition) in the complete 360° hemispheric area.

  1. Photoreactivity of biologically active compounds. VII. Interaction of antimalarial drugs with melanin in vitro as part of phototoxicity screening.

    Science.gov (United States)

    Kristensen, S; Orsteen, A L; Sande, S A; Tønnesen, H H

    1994-10-01

    The drugs commonly used in the treatment of malaria are photochemically unstable. Several of these compounds accumulate in melanin-rich tissues and cause toxic reactions which may be light induced. As part of the screening of the photochemical properties and phototoxic capabilities of antimalarials, the in vitro interaction of eight antimalarials with melanin was studied. The dissociation constant for the drug-melanin complex and the relative number of binding sites on melanin were estimated for six of the drugs using a curve-fitting program. The reaction rate for the formation of the melanin-drug complex was determined, and the complexes were further characterized by zeta potential measurements.

  2. Comparative study of the phototoxicity of two chrolin type photosensitizers, ATX-S10(Na) and verteporfin, on vascular endothelial and retinal pigment epithelial cells.

    Science.gov (United States)

    Huang, Yufang; Obana, Akira; Gohto, Yuko; Nakajima, Susumu

    2004-01-01

    To compare the phototoxicity in photodynamic therapy (PDT) of ATX-S10(Na) and Verteporfin on human microvascular endothelial cells (HMVEC), vascular endothelial cells of monkey choroid and retina (CRVEC), and human retinal pigment epithelial cells (HRPE). PDT was performed in two different ways. In short dye-exposure PDT, HMVEC and CRVEC were exposed to each photosensitizer for 5 minutes followed by laser irradiation of 670 nm wavelength for ATX-S10(Na) or 689 nm for Verteporfin without washing out the photosensitizer in the medium. In long dye-exposure PDT, the cells were exposed to photosensitizers for times ranging from 5 minutes to 2 hours, washed out the photosensitizers, followed by laser irradiation in a fresh medium. PDT was performed on HRPE with PDT doses that resulted in damaging 90% of the HMVEC (ED(90)). Phototoxicity was determined by MTS Assay 1 day after PDT. The degree of phototoxicity depended on the dye concentration, laser dose, and dye exposure time. In short dye-exposure PDT on HMVEC with a laser dose of 50 J/cm(2), the ED(90) was 6.3 microg/ml of ATX-S10(Na) and 0.04 microg/ml of Verteporfin, while in long dye-exposure PDT the ED(90) was 50.0 microg/ml of ATX-S10(Na) and 0.04 microg/ml of Verteporfin when the medium was supplemented with 5% fetal calf serum. The phototoxic rate on HMVEC was higher when the medium contained 5% as contrasted with 10% of serum. In short dye-exposure PDT, the ED(90) of CRVEC was 100 microg/ml of ATX-S10(Na) and an irradiance of 100 J/cm(2), and 0.08 microg/ml of Verteporfin and an irradiance of 100 J/cm(2) when the medium was supplemented with 10% serum. With some doses of short dye-exposure PDT, the ATX-S10(Na) achieved higher phototoxic rates on HMVEC and CRVEC than on the HRPE. However, long dye-exposure PDT with ATX-S10(Na) and short and long dye-exposure PDT with Vereteporfin failed to obtain higher phototoxic rates on HMVEC and CRVEC than on HRPE. Verteporfin had a higher phototoxicity than ATX-S10(Na) on

  3. Subluxation of the crystalline lens: a no-ring approach.

    Science.gov (United States)

    Rodrigues, Antonio Carlos L; Trivedi, Rupal H; Wilson, M Edward

    2012-01-01

    To report the surgical technique and outcomes of a no-ring approach to posterior chamber intraocular lens (IOL) implantation in children and young adults with subluxation of the crystalline lens. A three-piece 5.5-mm hydrophobic acrylic IOL was implanted in which the optic and one haptic were inside the capsular bag and the other haptic was in the ciliary sulcus. The implantations were done in 13 eyes of 10 patients with lens subluxation. One haptic was fixated in the ciliary sulcus by passing it through an operculum-shaped opening in the capsular bag edge, made between 2 and 3 clock hours, clockwise from the middle point of the subluxated area. The mean age of the 10 patients was 12.61 ± 8.04 years and the mean follow-up was 21.38 ± 11.29 months. The mean preoperative and postoperative best-corrected visual acuity (BCVA) was 1.15 ± 0.58 and 0.37 ± 0.17 logarithm of the minimum angle of resolution, respectively, in 11 measured eyes. The postoperative BCVA was 20/40 or better in 4 eyes (36.36%), between 20/40 and 20/60 in 6 eyes (54.54%), and between 20/80 and 20/100 in 1 eye (9.09%). The BCVA improved in all eyes. Postoperative IOL decentration between 1.0 and 1.5 mm occurred in 3 of 13 eyes (23.08%). The results indicate that the no-ring technique allows centration of an IOL implanted into a subluxated capsular bag without using capsule tension rings. Copyright 2012, SLACK Incorporated.

  4. Crystalline lens radioprotectors

    International Nuclear Information System (INIS)

    Belkacemi, Y.; Pasquier, D.; Castelain, B.; Lartigau, E.; Warnet, J.M.

    2003-01-01

    During more than a half of century, numerous compounds have been tested in different models against radiation-induced cataract. In this report, we will review the radioprotectors that have been already tested for non-human crystalline lens protection. We will focus on the most important published studies in this topic and the mechanisms of cyto-protection reported in. vitro and in. vivo from animals. The most frequent mechanisms incriminated in the cyto-protective effect are: free radical scavenging, limitation of lipid peroxidation, modulation of cycle progression increase of intracellular reduced glutathione pool, reduction of DNA strand breaks and limitation of apoptotic cell death. Arnifostine (or Ethyol) and anethole dithiolethione (or Sulfarlem), already used clinically as chemo- and radio-protectants, could be further test?r for ocular radioprotection particularly for radiation-induced cataract. (author)

  5. Contact Lens Wear at Altitude: Subcontact Lens Bubble Formation

    Science.gov (United States)

    1987-11-01

    incidence of (PMMA) lenses . Reported here are the results of contact lens subcontact lens bubble formation under scleral lenses at bubble studies with soft...vision from formation of large bubbles greater than 6,096 m (20,000 It). With soft contact lenses , bubble under their contact lenses . They also found...always located at the limbus and were without sequela to vision or corneal epithelial integrity. scleral lenses used by Jaeckle were permeable to gases

  6. Straylight Measurements in Contact Lens Wear

    NARCIS (Netherlands)

    van der Meulen, Ivanka J. E.; Engelbrecht, Leonore A.; van Vliet, Johannes M. J.; Lapid-Gortzak, Ruth; Nieuwendaal, Carla P.; Mourits, Maarten P.; Schlingemann, Reinier O.; van den Berg, Thomas J. T. P.

    2010-01-01

    Purpose: (1) To quantify the effect of contact lens wear on straylight in rigid and soft contact lens wearers and (2) to relate findings to morphological changes and subjective complaints. Methods: Straylight was measured using the Oculus C-Quant during contact lens wear and after contact lens

  7. Cochlear Implants

    Science.gov (United States)

    A cochlear implant is a small, complex electronic device that can help to provide a sense of sound. People who are ... of-hearing can get help from them. The implant consists of two parts. One part sits on ...

  8. Goserelin Implant

    Science.gov (United States)

    Goserelin implant is used in combination with radiation therapy and other medications to treat localized prostate cancer and is ... treatment of abnormal bleeding of the uterus. Goserelin implant is in a class of medications called gonadotropin- ...

  9. Phacoemulsification and foldable acrylic IOL implantation in children with treated retinoblastoma

    OpenAIRE

    Tartarella,Marcia Beatriz; Britez-Colombi,Gloria Fátima; Motono,Marcia; Chojniak,Martha Motono; Fortes Filho,Joao Borges; Belfort Jr.,Rubens

    2012-01-01

    PURPOSE: To study the results of cataract surgery in children with radiation-induced cataract after treatment for retinoblastoma. METHODS: Retrospective interventional case series. Six consecutive patients diagnosed with secondary cataracts due to radiation therapy for retinoblastoma. Intervention: Phacoemulsification and foldable acrylic intraocular lens implantation. Outcomes measu- red: Visual acuity, binocular indirect ophthalmoscopy and slit-lamp biomicroscopy. Aspirated lens material an...

  10. Comparison of TiO2 nanoparticle and graphene-TiO2 nanoparticle composite phototoxicity to Daphnia magna and Oryzias latipes

    Science.gov (United States)

    With a dramatic rise in complexity, needs of nanotoxicology research go beyond simple forms of nanomaterials. This study compared the phototoxicity of nano-TiO2and graphene-TiO2 nanocomposite (GNP). GNP was synthesized based on a hydrothermal method, which simultaneously performe...

  11. New trends in intraocular lens imaging

    Science.gov (United States)

    Millán, María S.; Alba-Bueno, Francisco; Vega, Fidel

    2011-08-01

    As a result of modern technological advances, cataract surgery can be seen as not only a rehabilitative operation, but a customized procedure to compensate for important sources of image degradation in the visual system of a patient, such as defocus and some aberrations. With the development of new materials, instruments and surgical techniques in ophthalmology, great progress has been achieved in the imaging capability of a pseudophakic eye implanted with an intraocular lens (IOL). From the very beginning, optical design has played an essential role in this progress. New IOL designs need, on the one hand, theoretical eye models able to predict optical imaging performance and on the other hand, testing methods, verification through in vitro and in vivo measurements, and clinical validation. The implant of an IOL requires a precise biometry of the eye, a prior calculation from physiological data, and an accurate position inside the eye. Otherwise, the effects of IOL calculation errors or misplacements degrade the image very quickly. The incorporation of wavefront aberrometry into clinical ophthalmology practice has motivated new designs of IOLs to compensate for high order aberrations in some extent. Thus, for instance, IOLs with an aspheric design have the potential to improve optical performance and contrast sensitivity by reducing the positive spherical aberration of human cornea. Monofocal IOLs cause a complete loss of accommodation that requires further correction for either distance or near vision. Multifocal IOLs address this limitation using the principle of simultaneous vision. Some multifocal IOLs include a diffractive zone that covers the aperture in part or totally. Reduced image contrast and undesired visual phenomena, such as halos and glare, have been associated to the performance of multifocal IOLs. Based on a different principle, accommodating IOLs rely on the effort of the ciliary body to increase the effective power of the optical system of the

  12. Contact Lens Related Corneal Ulcer

    OpenAIRE

    Loh, KY; Agarwal, P

    2010-01-01

    A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are: overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. Th...

  13. Contact Lens Visual Rehabilitation in Keratoconus and Corneal Keratoplasty

    Directory of Open Access Journals (Sweden)

    Yelda Ozkurt

    2012-01-01

    Full Text Available Keratoconus is the most common corneal distrophy. It’s a noninflammatory progressive thinning process that leads to conical ectasia of the cornea, causing high myopia and astigmatism. Many treatment choices include spectacle correction and contact lens wear, collagen cross linking, intracorneal ring segments implantation and finally keratoplasty. Contact lenses are commonly used to reduce astigmatism and increase vision. There are various types of lenses are available. We reviewed soft contact lenses, rigid gas permeable contact lenses, piggyback contact lenses, hybrid contact lenses and scleral-semiscleral contact lenses in keratoconus management. The surgical option is keratoplasty, but even after sutur removal, high astigmatism may stil exists. Therefore, contact lens is an adequate treatment option to correct astigmatism after keratoplasty.

  14. Short wavelength light filtering by the natural human lens and IOLs -- implications for entrainment of circadian rhythm

    DEFF Research Database (Denmark)

    Brøndsted, Adam Elias; Lundeman, Jesper Holm; Kessel, Line

    2013-01-01

    Photoentrainment of circadian rhythm begins with the stimulation of melanopsin containing retinal ganglion cells that respond directly to blue light. With age, the human lens becomes a strong colour filter attenuating transmission of short wavelengths. The purpose of the study was to examine...... the effect the ageing human lens may have for the photoentrainment of circadian rhythm and to compare with intraocular implant lenses (IOLs) designed to block UV radiation, violet or blue light....

  15. A course in lens design

    CERN Document Server

    Velzel, Chris

    2014-01-01

    A Course in Lens Design is an instruction in the design of image-forming optical systems. It teaches how a satisfactory design can be obtained in a straightforward way. Theory is limited to a minimum, and used to support the practical design work. The book introduces geometrical optics, optical instruments and aberrations. It gives a description of the process of lens design and of the strategies used in this process. Half of its content is devoted to the design of sixteen types of lenses, described in detail from beginning to end. This book is different from most other books on lens design because it stresses the importance of the initial phases of the design process: (paraxial) lay-out and (thin-lens) pre-design. The argument for this change of accent is that in these phases much information can be obtained about the properties of the lens to be designed. This information can be used in later phases of the design. This makes A Course in Lens Design a useful self-study book, and a suitable basis for an intro...

  16. Gabor lens theory

    International Nuclear Information System (INIS)

    Irani, A.A.

    1978-01-01

    The principle of using the space charge of an electron cloud to focus ion beams was first proposed by Gabor. Electrons are to be confined radially by means of an axial magnetic field B/sub z/ and axially by means of externally applied electric fields E/sub z/. An ion beam of charge density n/sub i/ much less than n/sub e/, the electron charge density can then be focused by the radial electric field set up by the electron cloud. The case considered here is that of a hollow cylindrical conductor charged to a potential +V with grounded rings on either side to set up the axial E/sub z/ field. A solenoid wound around the central conductor supplies the B/sub z/ field. Theoretical calculations are carried out for n/sub e/ maximum as a function of B/sub z/ due to radial confinement and V due to axial confinement and the focal length of the Gabor Lens is calculated

  17. Analysis of causes of intraocular lens explantations in the material of Department of Ophthalmology, Medical University of Lodz.

    Science.gov (United States)

    Wilczyński, Michał; Wilczyńska, Olena; Omulecki, Wojciech

    2009-01-01

    Implantation of intraocular lenses (IOLS) has become a standard practice in cataract surgery, however, similar to any other type of surgery, using IOLs is not complication-free and sometimes explantation of intraocular lenses may be necessary. This study was to gather data and analyze causes of intraocular lens explantations, performed in the Department of Ophthalmology, Medical University of Łódź. The data were gathered from medical documentation of all patients who underwent intraocular lens removal from January 2003 to July 2006. The examined group consisted of 16 patients (16 eyes): 9 women (fraction 0.56), and 7 men (fraction 0.44), at the age from 21 to 82 years (mean age 62.4 years, SD +/- 15.5). In all patients IOL explantation was performed under local, peribulbar anaesthesia. Two groups of patients were distinguished: patients who had an anterior chamber lens explanted (3 patients, fraction 0.19) and patients who underwent posterior chamber lens explantation (13 patients, fraction 0.81). Causes of AC IOL explantations were: vaulting of the IOL (1 eye, fraction 0.06), luxation of the IOL to the vitreous cavity (1 eye, fraction 0.06), and painful eyeball after anterior chamber lens implantation (1 eye, fraction 0.06). Causes of PC IOL explantations were: subluxation of the IOL (6 eyes, fraction 0.38), luxation of the lens to the vitreous cavity (3 eyes, fraction 0.19), luxation of the lens to the anterior chamber (1 eye, fraction 0.06), endophthalmitis (2 eyes, fraction 0.13) and incorrect lens power (1 eye, fraction 0.06). In the majority of eyes (n = 13, fraction 0.81) the removed implant was replaced by another intraocular lens, but 3 eyes (fraction 0.19) were left aphakic. We did not observe serious intra- or early postoperative complications which might influence the final result of the operation.

  18. Dental Implant Surgery

    Science.gov (United States)

    ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, surgery, ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, surgery, ...

  19. Design of a Test Bench for Intraocular Lens Optical Characterization

    Energy Technology Data Exchange (ETDEWEB)

    Alba-Bueno, Francisco; Vega, Fidel; Millan, Maria S, E-mail: francisco.alba-bueno@upc.edu, E-mail: fvega@oo.upc.edu, E-mail: millan@oo.upc.edu [Departamento de Optica y Optometria, Universidad Politecnica de Cataluna, C/ Violinista Vellsola 37, 08222 Terrassa (Spain)

    2011-01-01

    The crystalline lens is the responsible for focusing at different distances (accommodation) in the human eye. This organ grows throughout life increasing in size and rigidity. Moreover, due this growth it loses transparency through life, and becomes gradually opacified causing what is known as cataracts. Cataract is the most common cause of visual loss in the world. At present, this visual loss is recoverable by surgery in which the opacified lens is destroyed (phacoemulsification) and replaced by the implantation of an intraocular lens (IOL). If the IOL implanted is mono-focal the patient loses its natural capacity of accommodation, and as a consequence they would depend on an external optic correction to focus at different distances. In order to avoid this dependency, multifocal IOLs designs have been developed. The multi-focality can be achieved by using either, a refractive surface with different radii of curvature (refractive IOLs) or incorporating a diffractive surface (diffractive IOLs). To analyze the optical quality of IOLs it is necessary to test them in an optical bench that agrees with the ISO119679-2 1999 standard (Ophthalmic implants. Intraocular lenses. Part 2. Optical Properties and Test Methods). In addition to analyze the IOLs according to the ISO standard, we have designed an optical bench that allows us to simulate the conditions of a real human eye. To do that, we will use artificial corneas with different amounts of optical aberrations and several illumination sources with different spectral distributions. Moreover, the design of the test bench includes the possibility of testing the IOLs under off-axis conditions as well as in the presence of decentration and/or tilt. Finally, the optical imaging quality of the IOLs is assessed by using common metrics like the Modulation Transfer Function (MTF), the Point Spread Function (PSF) and/or the Strehl ratio (SR), or via registration of the IOL's wavefront with a Hartmann-Shack sensor and its

  20. Intraocular and crystalline lens protection from ultraviolet damage.

    Science.gov (United States)

    Sliney, David H

    2011-07-01

    Although the risks of excess solar ultraviolet (UV) exposure of the skin are well recognized, the need for eye protection is frequently overlooked, or when sunglasses are also recommended, specific guidance is wrong or is not explained. Guidance from the World Health Organization at its InterSun webpage advises people to wear "wrap-around" sunglasses under many conditions. The objective of this study was to examine the need for UV filtration in prescription lenses, contact lenses, and sunglasses. The geometry of UV exposure of both eyes, solar position, ground reflection, pupil size, and lid opening were studied. Because an accurate determination of cumulative ocular exposure is difficult, the cornea itself can serve as a biologic dosimeter, because photokeratitis is not experienced on a daily basis but does under certain ground-surface and sunlight conditions. From a knowledge of the UV-threshold dose required to produce photokeratitis, we have an upper level of routine ocular exposure to ambient UV. From ambient UV measurements and observed photokeratitis, the upper limits of UV exposure of the crystalline lens or an intraocular lens implant are estimated. The risk of excess UV exposure of the germinative cells of the lens is greatest from the side. Sunglasses can actually increase UV exposure of the germinative region of the crystalline lens and the corneal limbus by disabling the eyes' natural protective mechanisms of lid closure and pupil constriction! The level of UV-A risk is difficult to define. Proper UV-absorbing contact lenses offer the best mode for filtering needless exposure of UV radiation of the lens and limbus.

  1. Assessment of phototoxicity, skin irritation, and sensitization potential of polystyrene and TiO{sub 2} nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yoon-Hee; Jeong, Sang Hoon; Yi, Sang Min; Choi, Byeong Hyeok; Son, Sang Wook [Laboratory of Cell Signaling and Nanomedicine, Department of Dermatology and Division of Brain Korea 21 Project for Biomedical Science, Korea University College of Medicine, Seoul (Korea, Republic of); Kim, Yu-Ri; Kim, In-Kyoung; Kim, Meyoung-Kon [Department of Biochemistry and Molecular Biology, Korea University College of Medicine, Seoul (Korea, Republic of)

    2011-07-06

    The human skin equivalent model (HSEM) is well known as an attractive alternative model for evaluation of dermal toxicity. However, only limited data are available on the usefulness of an HSEM for nanotoxicity testing. This study was designed to investigate cutaneous toxicity of polystyrene and TiO{sub 2} nanoparticles using cultured keratinocytes, an HSEM, and an animal model. In addition, we also evaluated the skin sensitization potential of nanoparticles using a local lymph node assay with incorporation of BrdU. Findings from the present study indicate that polystyrene and TiO{sub 2} nanoparticles do not induce phototoxicity, acute cutaneous irritation, or skin sensitization. Results from evaluation of the HSEMs correspond well with those from animal models. Our findings suggest that the HSEM might be a useful alternative model for evaluation of dermal nanotoxicity.

  2. Sectioning a luxated intraocular lens inside the vitreous cavity.

    Science.gov (United States)

    Vilaplana, Daniel; Pazos, Marta

    2013-07-01

    We describe a new technique for sectioning an intraocular lens (IOL) inside the vitreous cavity. The IOL had a broken haptic and was accidentally luxated after a complicated cataract surgery with posterior capsule rupture. The primary indication to cut the IOL in half inside the vitreous cavity is to preserve the anterior capsule integrity, especially in a small-sized capsulotomy, allowing subsequent implantation of a new IOL in the sulcus with the optical zone captured in the capsulorhexis. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  3. Comparison of Contrast Sensitivity and Through Focus in Small-Aperture Inlay, Accommodating Intraocular Lens, or Multifocal Intraocular Lens Subjects.

    Science.gov (United States)

    Vilupuru, Srividhya; Lin, Ling; Pepose, Jay S

    2015-07-01

    To compare monocular and binocular mesopic contrast sensitivity and through focus following monocular implantation with KAMRA small-aperture inlay (AcuFocus, Irvine, California, USA) vs binocular implantation with an accommodating or multifocal intraocular lens (IOL) implant. Three-treatment randomized clinical trial of presbyopia-correcting IOLs with comparison to results from a previous nonrandomized multicenter clinical trial on the KAMRA corneal inlay. Study population of 507 subjects with KAMRA inlays; predetermined subgroups included 327 subjects that underwent contrast sensitivity testing and another 114 subjects for defocus curve testing, along with 78 subjects randomized between bilateral Crystalens Advanced Optics (AO) (Bausch + Lomb Surgical, Aliso Viejo, California, USA), AcrySof IQ ReSTOR +3.0 D (Alcon Laboratories, Fort Worth, Texas, USA), or Tecnis +4D Multifocal (MF) (Abbott Medical Optics, Santa Ana, California, USA) IOL. KAMRA inlay subjects demonstrated improved intermediate and near vision with minimal to no change to distance vision, better contrast sensitivity in the inlay eye when compared to the multifocals, and better binocular contrast sensitivity when compared to all 3 intraocular lenses. Crystalens AO was superior in uncorrected intermediate vision compared to the KAMRA inlay, but not in distance-corrected intermediate, and was worse in near vision. The multifocals were superior in near vision at their respective optimum near focus points, but worse in intermediate vision compared to both KAMRA inlay and Crystalens AO. The demonstrated performance of these devices should be considered, along with subjects' visual demands and expectations, degree of crystalline lens dysfunction, and other ocular characteristics, in guiding the selection of small-aperture corneal inlay or specific intraocular lens in the correction of presbyopia. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Live Cell Imaging: Assessing the Phototoxicity of 488 and 546 nm Light and Methods to Alleviate it.

    Science.gov (United States)

    Douthwright, Stephen; Sluder, Greenfield

    2017-09-01

    In live cell imaging of fluorescent proteins, phototoxicity of the excitation light can be problematical. Cell death is obvious, but reduced cell viability can make the interpretation of observations error prone. We characterized the phototoxic consequences of 488 and 546 nm light on untransformed human cells and tested methods that have or could be used to alleviate photodamage. Unlabeled RPE1 cells were given single 0.5-2.5 min irradiations in early G1 from a mercury arc lamp on a fluorescence microscope. Four hundred eighty-eight nanometer light produced a dose-dependent decrease in the percentage of cells that progressed to mitosis, slowing of the cell cycle for some of those entering mitosis, and a ∼12% incidence of cell death for the highest dose. For 546 nm light we found a 10-15% reduction in the percentage of cells entering mitosis, no strong dose dependency, and a ∼2% incidence of cell death for the longest irradiations. For cells expressing GFP-centrin1 or mCherry-centrin1, fewer entered mitosis for each dose than unlabeled cells. For constant total dose 488 nm light irradiations of unlabeled cells, reducing the intensity 10-fold or spreading the exposures out as a series of 10 sec pulses at 1 min intervals produced a minor and not consistent improvement in the percentage of cells entering mitosis. Reducing oxidative processes, by culturing at ∼3% oxygen or adding the reducing agent Trolox noticeably increased the fraction of cells entering mitosis. Thus, for long-term imaging there can be value to using RFP constructs and for GFP-tagged proteins reducing oxidative processes. J. Cell. Physiol. 232: 2461-2468, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  5. [Shower PUVA: a new possibility for topical PUVA therapy. Phototoxicity in relation to shower time, water temperature and skin type].

    Science.gov (United States)

    Radenhausen, M; Tebbe, B; Orfanos, C E

    1999-10-01

    During the past few years, bath PUVA has become established as an effective treatment for various dermatoses and especially for psoriasis. Using 3,4,5 trimethylpsoralen (TMP) in combination with subsequent UVA irradiation, a shower PUVA has been developed as an alternative in local PUVA therapy. This involves moistening the patient's skin - with the exception of the head and neck area - in a shower using water containing psoralen (TMP concentration 0,27 mg/l). The advantages of shower PUVA method are that time, space and cost savings are possible and that only a slight amount of physical exertion is required by the patient standing in the shower compared to immersing the whole body during bath PUVA therapy. The efficacy and practicability of shower PUVA were evaluated using the minimal phototoxic dose (MPD) for healthy volunteers assessing water temperature (33-38 degrees C), shower time (5-10 min), and UVA dose (0,06-1,0 J/cm(2)). Additionally, the time course of TMP-induced photosensitivity was observed over a period of 4 hours after the shower. Using a TMP concentration of 0,27 mg/l, the MPD for skin type I-II lay between 0,125-0,375 J/cm(2) and for skin type III-IV between 0,375-1,0 J/cm(2). Photosensitivity was induced by shower PUVA within 5-10 minutes shower time and at 33-38 degrees C water temperature. MPD exhibited an inverse correlation to temperature but no differences were apparent for shower times between 5 and 10 minutes. Photosensitivity completely disappeared within 2 hours. Minimal phototoxic doses using TMP in shower PUVA are comparable with classical bath PUVA when taking skin type into account. These results support the therapeutic use of shower PUVA using TMP.

  6. [Contact lens care and maintenance].

    Science.gov (United States)

    Bloise, L

    2017-04-01

    All contact lenses with replacement schedules longer than daily must be maintained. At each step of their use, the lenses may be contaminated. Contact lens solutions perform the essential functions of cleaning, decontaminating and preserving the lenses to prevent infectious problems and improve wearing comfort. Contact lens contamination essentially comes from hands, cleaning solutions, cases, water and the environment. The pathogenic microorganisms are mainly Gram-negative bacteria, fungi and amoebae. Contact lens deposits may or may not have an organic origin. Their presence increases the risk of infection because they serve as a nutrient matrix for microbes, and they are responsible for wearing discomfort. Contact lens solutions differ in their composition, their mechanism of action and the concentration of the various agents. To prescribe the best lens care system to each wearer and for each material, it is necessary to be very familiar with them. Maintenance is the main cause of discomfort with contact lenses, either through improper use, solution-material incompatibility, or a reaction of the wearer to the components. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  7. [Clinical applications of ultrasound biomicroscopy in diagnosis and treatment of lens subluxation].

    Science.gov (United States)

    Liu, Yi-Zhi; Liu, Yu-Hua; Wu, Ming-Xing; Luo, Li-Xia; Zhang, Xin-Yu; Cai, Xiao-Yu; Chen, Xiu-Qi

    2004-03-01

    To evaluate the clinical value in diagnosis and treatment of lens subluxation using ultrasound biomicroscopy (UBM). This study comprised 29 patients (32 eyes) that had cataract with subluxated lenses due to different causes admitted into our hospital between November 2000 and January 2002. All eyes received UBM examination preoperatively and postoperatively. Capsular tension ring (CTR) implantations were performed using different technique according to UBM examination. Then all patients received phacoemulsification and intraocular lens (IOL) implantation. The location of IOL and CTR and complications were evaluated postoperatively. Different kinds of subluxated lens shown different manifestations in UBM. The degree of zonular defect can be evaluated with UBM preoperatively. With UBM examination preoperatively, extent of lens subluxation less than 1/2 quadrant in 19 eyes while more than 1/2 quadrant in other 13 eyes were observed. Postoperative UBM examination in this series shown that CTRs were holding in place except one attached to the iris root. IOLs in 29 eyes were in proper position while IOLs in 3 patients were slightly tilted. The degree and extent of lens subluxation can be evaluated using UBM examinations preoperatively, which is necessary in the selection of surgical protocol. With postoperative UBM examinations, a precise observation on the actual location of CTR and IOL can be achieved to produce an objective evaluation of the surgical outcomes.

  8. The SNAP Strong Lens Survey

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, P.

    2005-01-03

    Basic considerations of lens detection and identification indicate that a wide field survey of the types planned for weak lensing and Type Ia SNe with SNAP are close to optimal for the optical detection of strong lenses. Such a ''piggy-back'' survey might be expected even pessimistically to provide a catalogue of a few thousand new strong lenses, with the numbers dominated by systems of faint blue galaxies lensed by foreground ellipticals. After sketching out our strategy for detecting and measuring these galaxy lenses using the SNAP images, we discuss some of the scientific applications of such a large sample of gravitational lenses: in particular we comment on the partition of information between lens structure, the source population properties and cosmology. Understanding this partitioning is key to assessing strong lens cosmography's value as a cosmological probe.

  9. Automated Fresnel lens tester system

    Energy Technology Data Exchange (ETDEWEB)

    Phipps, G.S.

    1981-07-01

    An automated data collection system controlled by a desktop computer has been developed for testing Fresnel concentrators (lenses) intended for solar energy applications. The system maps the two-dimensional irradiance pattern (image) formed in a plane parallel to the lens, whereas the lens and detector assembly track the sun. A point detector silicon diode (0.5-mm-dia active area) measures the irradiance at each point of an operator-defined rectilinear grid of data positions. Comparison with a second detector measuring solar insolation levels results in solar concentration ratios over the image plane. Summation of image plane energies allows calculation of lens efficiencies for various solar cell sizes. Various graphical plots of concentration ratio data help to visualize energy distribution patterns.

  10. Compliance among soft contact lens wearers.

    Science.gov (United States)

    Kuzman, Tomislav; Kutija, Marija Barisić; Masnec, Sanja; Jandroković, Sonja; Mrazovac, Danijela; Jurisić, Darija; Skegro, Ivan; Kalauz, Miro; Kordić, Rajko

    2014-12-01

    Contact lens compliance is proven to be crucial for preventing lens wear-related complications because of the interdependence of the steps in lens care regime and their influence on lens system microbial contamination. Awareness of the patients' lens handling compliance as well as correct recognition of non-compliant behaviours is the basis for creating more targeted strategies for patient education. The aim of this study was to investigate compliance among soft contact lens (SCL) wearers in different aspects of lens care handling and wearing habits. In our research 50 asymptomatic lens wearers filled out a questionnaire containing demographic data, lens type, hygiene and wearing habits, lenses and lens care system replacement schedule and self-evaluation of contact lens handling hygiene. We established criteria of compliance according to available manufacturer's recommendations, prior literature and our clinical experience. Only 2 (4%) of patients were fully compliant SCL wearers. The most common non-compliant behaviours were insufficient lens solution soaking time (62%), followed by failure to daily exchange lens case solution and showering while wearing lenses. 44% of patients reported storing lenses in saline solution. Mean lens storage case replacement was 3.6 months, with up to 78% patients replacing lens case at least once in 3 months. Average grade in self evaluating level of compliance was very good (4 +/- 0.78) (from 1-poor level of hygiene to 5-great level of hygiene). Lens wearers who reported excessive daily lens wear and more than 10 years of lens wearing experience were also found to be less compliant with other lens system care procedures. (t = -2.99, df=47, p lens system maintenance steps. Most common non-compliant behaviours were the ones that are crucial for maintaining lens sterility and preventing infection. Despite the low objective compliance rate, self grading was relatively high. Therefore, these results indicate the need for patient

  11. Computer-aided lens assembly

    Science.gov (United States)

    Tomlinson, Richard; Alcock, Rob; Petzing, Jon; Coupland, Jeremy

    2004-01-01

    We propose a computer-aided method of lens manufacture that allows assembly, adjustment, and test phases to be run concurrently until an acceptable level of optical performance is reached. Misalignment of elements within a compound lens is determined by a comparison of the results of physical ray tracing by use of an array of Gaussian laser beams with numerically obtained geometric ray traces. An estimate of misalignment errors is made, and individual elements are adjusted in an iterative manner until performance criteria are achieved. The method is illustrated for the alignment of an air-spaced doublet.

  12. Acanthamoeba keratitis. Contact lens and noncontact lens characteristics.

    Science.gov (United States)

    Chynn, E W; Lopez, M A; Pavan-Langston, D; Talamo, J H

    1995-09-01

    To identify potential differences in time to diagnosis and final visual outcome between contact lens and noncontact lens users with Acanthamoeba keratitis. Prior studies have shown early diagnosis and therapy to be related to outcome but have not analyzed differences among patients with and without contact lenses. A retrospective analysis of 11 consecutive cases (involving 13 eyes) of Acanthamoeba keratitis diagnosed at one institution over a 3-year period. Mean time to diagnosis was significantly longer in noncontact lens users versus those who wore contact lenses (mean, 5.8 versus 3.3 weeks). Fifty percent of patients who did not wear contact lenses had a poor outcome (visual acuity worse than 20/40 or penetrating keratoplasty) versus 14% of patients who wore contact lenses. Diagnoses were made later in patients without contact lenses, and these patients had a worse visual outcome than those with Acanthamoeba keratitis who wore contact lenses. All patients with unresponsive microbial keratitis, even those without contact lens use, should be evaluated for Acanthamoeba.

  13. A microcapillary lens for X-rays

    CERN Document Server

    Dudchik, Y I

    1999-01-01

    A new design of a compound refractive lens for X-rays is proposed. The lens is made as a set of glue microlenses placed in a glass capillary. The technique of lens fabrication is described. Results of ray tracing calculations for 8 and 15 keV photons are represented.

  14. The Ultrawideband Leaky Lens Antenna

    NARCIS (Netherlands)

    Bruni, S.; Neto, A.; Marliani, F.

    2007-01-01

    A novel directive and nondispersive antenna is presented: the ultrawideband (UWB) leaky lens. It is based on the broad band Cherenkov radiation occurring at a slot printed between different infinite homogeneous dielectrics. The first part of the paper presents the antenna concept and the UWB design.

  15. Spinning pipe gas lens revisited

    CSIR Research Space (South Africa)

    Mafusire, C

    2008-01-01

    Full Text Available , there is little information on optical phase aberrations and no study to date on the propagation parameters of the laser beam, but has rather remained rooted in the domain of ray optics. Researchers revisit the spinning pipe gas lens in this paper with new...

  16. Assessment of primary eye and skin irritants by in vitro cytotoxicity and phototoxicity models: an in vitro approach of new arginine-based surfactant-induced irritation

    International Nuclear Information System (INIS)

    Benavides, T.; Mitjans, M.; Martinez, V.; Clapes, P.; Infante, M.R.; Clothier, R.H.; Vinardell, M.P.

    2004-01-01

    Extensive efforts have been made, recently, to find surfactants with lower irritation potential than those presently commercially available, for use in pharmaceutical and cosmetic preparations. Cytotoxic and phototoxic effects of a novel family of dicationic arginine-diglyceride surfactant compounds, 1,2-diacyl,3-O-(L-arginyl)-rac-glycerol with alkyl chain lengths in the range from 8 to 14 carbon atoms, were compared to three commercial surfactants. The end-points used to assess toxicity were the red blood cell lysis assay and uptake of the vital dye neutral red 24 h after dosing (NRU), respectively. Two immortalized cell lines, murine fibroblast cell line, 3T3, and one human keratinocyte cell line, HaCaT, were used as in vitro models to predict the potential phototoxicity which could result in irritation, determined by resazurin reduction to resorufin and neutral red uptake (NRU). All tested surfactants had cytotoxicity effects as demonstrated by and decrease of NR uptake, which showed a clear concentration-response relationship. Concentrations resulting in 50% inhibition of NR uptake (IC 50 ) range from 1 μmol l -1 (hexadecyl trimethyl ammonium bromide) to 565 μmol l -1 (12,12-L-arginine). Erythrocyte haemolysis also showed a clear concentration-response relationship, the 50% of haemolysis ranged from 37 μmol l -1 (10,10-L-arginine) to 151 μmol l -1 (sodium lauryl sulphate). Phototoxicity was performed with 12,12-L-acetyl-arginine, the most stable chemical structure. The validated 3T3 NRU photoxicity assay was used and revealed a phototoxic potential

  17. Effect of aqueous media on the copper-ion-mediated phototoxicity of CuO nanoparticles toward green fluorescent protein-expressing Escherichia coli.

    Science.gov (United States)

    Shang, Enxiang; Li, Yang; Niu, Junfeng; Guo, Huiyuan; Zhou, Yijing; Liu, Han; Zhang, Xinqi

    2015-12-01

    Quantitative comparison of different aqueous media on the phototoxicity of copper oxide nanoparticles (CuO NPs) is crucial for understanding their ecological effects. In this study, the phototoxicity of CuO NPs toward the green fluorescent protein-expressing Escherichia coli (GFP-E. coli) under UV irradiation (365 nm) was investigated in Luria-Bertani medium (LB), NaCl solution, deionized water (DI) and phosphate-buffered saline (PBS). The phototoxicity of CuO NPs toward GFP-E. coli decreased in the order of DI>NaCl>PBS>LB because of different released concentrations of Cu(2+). The 3h released Cu(2+) concentrations by 10mg/L CuO NPs in DI water, NaCl solution, LB medium, and PBS were 1946.3 ± 75.6, 1242.5 ± 47.6, 1023.4 ± 41.2, and 1162.1 ± 41.9 μg/L, respectively. Transmission electron microscope and laser scanning confocal microscope images of E. coli exposed to CuO NPs demonstrated that the released Cu(2+) resulted in fragmentation of bacterial cell walls, leakage of intracellular components, and finally death of bacteria in four media after UV light irradiation. In each medium, the bacterial mortality rate logarithmically increased with the releasing concentrations of Cu(2+) by CuO NPs (R(2)>0.90) exposed to 3h UV light. This study highlights the importance of taking into consideration of water chemistry when the phototoxicity of CuO NPs is assessed in nanotoxicity research. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Tube entrance lens focus control

    Science.gov (United States)

    Weisser, D. C.; Fifield, L. K.; Kitchen, T. F. G.; Tunningley, T. B.; Lobanov, N. R.; Muirhead, A. G.

    2013-02-01

    The entrance of the accelerator tube in a large electrostatic accelerator imposes a strong lens that dominates the beam optics. The magnification of the lens is large because of the low injection energy, the high voltage gradient of the acceleration tube and the long distance to the terminal. In the absence of the acceleration, the magnification would produce an unacceptably large beam spot at the terminal. The tyranny of the lens is especially irksome when the accelerator is required to operate at a lower terminal voltage than the one corresponding to the nominal gradient at high voltage. One way around the difficulty, used in NEC Pelletron accelerators, is to insert a series of nylon and steel rods that short together units of the acceleration structure at the terminal leaving the ones near the entrance close to the nominal gradient for optimum transmission. This operation takes time and risks the loss of insulating gas. Another alternative used in the 25URC at Oak Ridge National Laboratory, is to focus the beam at the tube entrance, substantially diluting the effect of the entrance lens. The beam then diverges and so requires an additional lens part way to the terminal. This solution is only partially effective and still necessitates use of shorting rods for low voltage operation. The fact that these elaborate strategies are used is evidence that the alternative of lowering the injection energy as the terminal voltage is lowered imposes enough problems that it is not used in practice. We have modeled a solution that controls the voltage gradient at the tube entrance using an external power supply. This not only maintains the focusing effect of the lens but provides the opportunity to tune the beam by adjusting the entrance lens. A 150 kV power supply outside the pressure vessel feeds a controllable voltage through a high voltage feed-through to the fifth electrode of the accelerator tube. Thus 150 kV on this electrode creates the nominal gradient of 30 kV per

  19. Lens stem cells may reside outside the lens capsule: an hypothesis

    Directory of Open Access Journals (Sweden)

    Meyer Rita A

    2007-06-01

    Full Text Available Abstract In this paper, we consider the ocular lens in the context of contemporary developments in biological ideas. We attempt to reconcile lens biology with stem cell concepts and a dearth of lens tumors. Historically, the lens has been viewed as a closed system, in which cells at the periphery of the lens epithelium differentiate into fiber cells. Theoretical considerations led us to question whether the intracapsular lens is indeed self-contained. Since stem cells generate tumors and the lens does not naturally develop tumors, we reasoned that lens stem cells may not be present within the capsule. We hypothesize that lens stem cells reside outside the lens capsule, in the nearby ciliary body. Our ideas challenge the existing lens biology paradigm. We begin our discussion with lens background information, in order to describe our lens stem cell hypothesis in the context of published data. Then we present the ciliary body as a possible source for lens stem cells, and conclude by comparing the ocular lens with the corneal epithelium.

  20. Toxicity and phototoxicity of water-accommodated fraction obtained from Prestige fuel oil and Marine fuel oil evaluated by marine bioassays.

    Science.gov (United States)

    Saco-Alvarez, Liliana; Bellas, Juan; Nieto, Oscar; Bayona, Josep María; Albaigés, Joan; Beiras, Ricardo

    2008-05-15

    Acute toxicity and phototoxicity of heavy fuel oil extracted directly from the sunken tanker Prestige in comparison to a standard Marine fuel oil were evaluated by obtaining the water-accommodated fraction (WAF) and using mussel Mytilus galloprovincialis and sea urchin Paracentrotus lividus embryogenesis bioassays, and copepod Acartia tonsa and fish Cyprinodon variegatus survival bioassays. Aromatic hydrocarbon (AH) levels in WAF were measured by gas chromatography. Prestige WAF was not phototoxic, its median effective concentrations (EC50) were 13% and 10% WAF for mussel and sea urchin respectively, and maximum lethal threshold concentrations (MLTC) were 12% and 50% for copepod and fish respectively. Marine WAF resulted phototoxic for mussel bioassay. EC50s of Marine WAF were 50% for sea urchin in both treatments and 20% for mussel under illumination. Undiluted Marine WAF only caused a 20% decrease in mussel normal larvae. Similar sensitivities were found among sea urchins, mussels and copepods, whilst fish were less sensitive. Unlike Marine WAF, Prestige WAF showed EC50 values at dilutions below 20%, and its toxicity was independent of lighting conditions. The differences in toxicity between both kinds of fuel could not be explained on the basis of total AH content.

  1. Modern lens antennas for communications engineering

    CERN Document Server

    Thornton, John

    2012-01-01

    The aim of this book is to present the modern design principles and analysis of lens antennas. It gives graduates and RF/Microwave professionals the design insights in order to make full use of lens antennas.  Why do we want to write a book in lens antennas? Because this topic has not been thoroughly publicized, its importance is underestimated. As antennas play a key role in communication systems, recent development in wireless communications would indeed benefit from the characteristics of lens antennas: low profile, and low cost etc.  The major advantages of lens antennas are na

  2. Implantation metallurgy

    International Nuclear Information System (INIS)

    Picraux, S.T.

    1975-01-01

    Important changes in the near-surface physical properties of metals were obtained by high-fluence ion implantation. Recently there have been an increasing number of studies of the behavior of implanted species with the aim of understanding the detailed physical processes that occur in an implanted metal layer. A key aspect of these implantation metallurgy studies has been the ability to form uniquely controlled systems in the near-surface regions of metals that can be studied with accurate depth resolution. Metallurgical parameters that may be difficult or impossible to obtain by other means can be measured. Also, parameters that depend on the implantation process, due to the athermal introduction of atoms and defects can be determined. Thus the dual objective of implantation metallurgy is to obtain information to improve understanding of the microscopic aspects of metallurgy and to understand how to form controlled new metallurgical systems. Examples of parameters studied include implanted impurity location, diffusion, enhanced diffusion, solubility, precipitation, and dissolution. (auth)

  3. Nanostructured delivery system for zinc phthalocyanine: preparation, characterization, and phototoxicity study against human lung adenocarcinoma A549 cells

    Directory of Open Access Journals (Sweden)

    Mariana da Volta Soares

    2011-01-01

    Full Text Available Mariana da Volta Soares1, Mainara Rangel Oliveira1, Elisabete Pereira dos Santos1, Lycia de Brito Gitirana2, Gleyce Moreno Barbosa3, Carla Holandino Quaresma3, Eduardo Ricci-Júnior11Department of Medicines, Laboratório de Desenvolvimento Galênico (LADEG, Faculty of Pharmacy, 2Laboratory of Animal and Comparative Histology, Glycobiology Research Program, Institute of Biomedical Science, 3Department of Medicines, Laboratório Multidisciplinar de Ciências Farmacêuticas, Faculty of Pharmacy, Federal University of Rio de Janeiro (UFRJ, Rio de Janeiro, BrazilAbstract: In this study, zinc phthalocyanine (ZnPc was loaded onto poly-ε-caprolactone (PCL nanoparticles (NPs using a solvent emulsification–evaporation method. The process yield and encapsulation efficiency were 74.2% ± 1.2% and 67.1% ± 0.9%, respectively. The NPs had a mean diameter of 187.4 ± 2.1 nm, narrow distribution size with a polydispersity index of 0.096 ± 0.004, zeta potential of -4.85 ± 0.21 mV, and spherical shape. ZnPc has sustained release, following Higuchi’s kinetics. The photobiological activity of the ZnPc-loaded NPs was evaluated on human lung adenocarcinoma A549 cells. Cells were incubated with free ZnPc or ZnPc-loaded NPs for 4 h and then washed with phosphate-buffered saline. Culture medium was added to the wells containing the cells. Finally, the cells were exposed to red light (660 nm with a light dose of 100 J/cm2. The cellular viability was determined after 24 h of incubation. ZnPc-loaded NPs and free photosensitizer eliminated about 95.9% ± 1.8% and 28.7% ± 2.2% of A549 cells, respectively. The phototoxicity was time dependent up to 4 h and concentration dependent at 0–5 µg ZnPc. The cells viability decreased with the increase of the light dose in the range of 10–100 J/cm2. Intense lysis was observed in the cells incubated with the ZnPc-loaded NPs and irradiated with red light. ZnPc-loaded PCL NPs are the release systems that promise photodynamic

  4. Contact lens surface by electron beam

    International Nuclear Information System (INIS)

    Shin, Jung Hyuck; Lee, Suk Ju; Hwang, Kwang Ha; Jeon Jin

    2011-01-01

    Contact lens materials needs good biocompatibility, high refractive index, high optical transparency, high water content etc. Surface treat method by using plasma and radiation can modify the physical and/or chemical properties of the contact lens surface. Radiation technology such as electron beam irradiation can apply to polymerization reaction and enhance the functionality of the polymer.The purpose of this study is to modify of contact lens surface by using Eb irradiation technology. Electron beam was irradiated to the contact lens surface which was synthesized thermal polymerization method and commercial contact lens to modify physical and chemical properties. Ft-IR, XP, UV-vis spectrophotometer, water content, oxygen trans-metastability were used to characterize the surface state, physicochemical, and optical property of the contact lens treated with Eb. The water content and oxygen transmissibility of the contact lens treated with Eb were increased due to increase in the hydrophilic group such as O-C=O and OH group on the contact lens surface which could be produced by possible reaction between carbon and oxygen during the Eb irradiation. All of the lenses showed the high optical transmittance above 90%. In this case of B/Es, TES, Ti contact lens, the optical transmittance decreased about 5% with increasing Eb dose in the wavelength of UV-B region. The contact lens modified by Eb irradiation could improve the physical properties of the contact lens such as water content and oxygen transmissibility

  5. Lens decenter and tilt measurement by interferogram

    Science.gov (United States)

    Hung, Min-Wei; Wu, Wen-Hong; Huang, Kuo-Cheng

    2009-11-01

    For the recent years, the vigorous development of the electro-optic industry, particularly the digital camera and the cellular phone camera, has placed a larger and larger demand for the optical devices. Among the optical lens, the aspherical optical lens plays the key component because the aspherical lens may provide better imaging quality then the spherical lens does. For the manufacturing reason, the aspherical lens is prone to a decenter or tilt issue with respect to the optical axes of its two surfaces. To measure decenter and tile error specifically would help to obviate the deficient lens, but most of the present measuring method can't provide this function. This paper proposed a new method to specifically measure the decenter and tile of lens by observing the interferogram of each surface. And the corresponding measuring instrument, which contains interferometer and motion stages, was introduced as well.

  6. Outcomes of Lensectomy in Hereditary Lens Subluxation

    Directory of Open Access Journals (Sweden)

    Mohammad-Hossein Dehghan

    2008-12-01

    Full Text Available

    PURPOSE: To evaluate the results of pars plana lensectomy in patients with hereditary lens subluxation. METHOD: Hospital records of patients with hereditary lens subluxation who had undergone pars plana lensectomy at Labbafinejad Medical Center, Tehran-Iran from 1996 to 2003 were reviewed. Patients with more than 6 months of follow up were included. Underlying disorders, best corrected visual acuity (BCVA before and after surgery, intraocular pressure (IOP, postoperative refraction and complications were evaluated. RESULTS: Overall, records of 87 eyes of 49 patients including 27 male and 22 female subjects were reviewed. Mean follow up duration was 20±18 months. Underlying disorders leading to lens subluxation included Marfan syndrome (79.5%, Weill-Marchesani syndrome (8.2%, simple ectopia lentis (8.2%, and homocystinuria (4.1%. The most common indication for surgery was non-correctable refractive error (92.1%. Mean BCVA was 1.13 LogMAR (20/250 preoperatively, which improved to 0.26 LogMAR (20/30-20/40 postoperatively (P < 0.001. BCVA better than 20/40 was achieved in 82.8% of cases after surgery. Angle-supported anterior chamber intraocular lens (ACIOL was implanted in

  7. Cochlear implant

    Science.gov (United States)

    ... made up of a microphone/receiver, a speech processor, and an antenna. This part of the implant ... ear. This sound is sent to a speech processor, which is most often connected to the microphone ...

  8. Lens subluxation grading system: predictive value for ectopia lentis surgical outcomes

    Directory of Open Access Journals (Sweden)

    Mauro Waiswol

    2009-03-01

    Full Text Available Objective: To present a classification system to grade ectopia lentis and to assess its usefulness as a predictor for surgical outcomes. Methods: Fifty-one eyes of 28 patients with either simple (19 patients or Marfan syndrome-associated ectopia lentis (nine patients with variable degrees of subluxation were operated on. Lens subluxation intensity was graded according to the lens subluxation grading system (LSGS from grade 1 (lens on the whole pupillary area up to grade 4 (lens absent from the pupillary area. Thirty eyes underwent cataract extraction (“dry” aspiration with endocapsular ring and in-the-bag intraocular lens (IOL implantation. Twenty-one eyes underwent cataract extraction (“dry” aspiration with scleral fixation of the IOL. The predictive value of the LSGS was assessed by analyzing the post-operative outcomes, including visual acuity (VA, endothelial cell loss, and complications for each grade on the grading system. Rresults: Patients were classified into grade 1 (19.6%, grade 2 (51% and grade 3 (29.4%. Post-operative VA was lower for eyes with larger degrees of subluxation. The higher the subluxation grade, the higher the endothelial cell loss, as well as, the frequency of vitreous loss and surgical time. Higher subluxation grades prevented optimal surgical outcomes with endocapsular ring and in-the-bag IOL implantation. Cconclusions: The LSGS provides an estimate of the surgical success of ectopia lentis. Adequate standardization of lens subluxation is crucial for understanding studies dealing with the surgical correction of this disorder.

  9. Sponge-Associated Bacteria Produce Non-cytotoxic Melanin Which Protects Animal Cells from Photo-Toxicity.

    Science.gov (United States)

    Vijayan, Vijitha; Jasmin, Chekidhenkuzhiyil; Anas, Abdulaziz; Parakkaparambil Kuttan, Sreelakshmi; Vinothkumar, Saradavey; Perunninakulath Subrayan, Parameswaran; Nair, Shanta

    2017-09-01

    Melanin is a photo-protective polymer found in many organisms. Our research shows that the bacteria associated with darkly pigmented sponges (Haliclona pigmentifera, Sigmadocia pumila, Fasciospongia cavernosa, Spongia officinalis, and Callyspongia diffusa) secrete non-cytotoxic melanin, with antioxidant activity that protects animal cells from photo-toxicity. Out of 156 bacterial strains screened, 22 produced melanin and these melanin-producing bacteria (MPB) were identified as Vibrio spp., Providencia sp., Bacillus sp., Shewanella sp., Staphylococcus sp., Planococcus sp., Salinococcus sp., and Glutamicibacter sp. Maximum melanin production was exhibited by Vibrio alginolyticus Marine Microbial Reference Facility (MMRF) 534 (50 mg ml -1 ), followed by two isolates of Vibrio harveyi MMRF 535 (40 mg ml -1 ) and MMRF 546 (30 mg ml -1 ). Using pathway inhibition assay and FT-IR spectral analysis, we identified the melanin secreted into the culture medium of MPB as 1,8-dihydroxynaphthalene-melanin. The bacterial melanin was non-cytotoxic to mouse fibroblast L929 cells and brine shrimps up to a concentration of 200 and 500 ppm, respectively. Bacterial melanin showed antioxidant activity at very low concentration (IC 50 -9.0 ppm) and at 50 ppm, melanin protected L929 cells from UV-induced intracellular reactive oxygen stress. Our study proposes sponge-associated bacteria as a potential source of non-cytotoxic melanin with antioxidant potentials.

  10. Phototoxicity, Pseudoporphyria, and Photo-onycholysis Due to Voriconazole in a Pediatric Patient With Leukemia and Invasive Aspergillosis.

    Science.gov (United States)

    Willis, Zachary I; Boyd, Alan S; Di Pentima, M Cecilia

    2015-06-01

    Voriconazole is a triazole antifungal agent superior to amphotericin B in the treatment of invasive aspergillosis. It is generally well tolerated and has excellent oral bioavailability, providing significant benefit in the treatment of invasive fungal infections. There have been numerous reports of dermatologic reactions to this agent, including erythroderma, cheilitis, Stevens-Johnson syndrome, discoid lupus erythematosus, pseudoporphyria, squamous cell carcinoma, and photosensitivity reactions. Pseudoporphyria, a dermatologic condition mimicking porphyria cutanea tarda, has been described as an adverse effect of voriconazole use. Clinical findings include photosensitivity, vesicles, bullae, milia, and scarring in sun-exposed areas. Photo-onycholysis is a phenomenon of nail discoloration and onycholysis that has been described in the setting of a phototoxic drug reaction and pseudoporphyria. Implicated drugs have most commonly been tetracyclines, fluoroquinolones, and psoralens; others have been reported as well. We report a case of a pediatric patient with leukemia who developed symptoms consistent with pseudoporphyria and later photo-onycholysis while being treated with voriconazole. To our knowledge, this is the first reported case of pseudoporphyria due to voriconazole in a pediatric patient and the first reported case of photo-onycholysis as a consequence of voriconazole use. © The Author 2014. Published by Oxford University Press on behalf of the Pediatric Infectious Diseases Society. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  11. Metabolic activation of pyrrolizidine alkaloids leading to phototoxicity and photogenotoxicity in human HaCaT keratinocytes.

    Science.gov (United States)

    Wang, Chia-Chi; Xia, Qingsu; Li, Meng; Wang, Shuguang; Zhao, Yuewei; Tolleson, William H; Yin, Jun-Jie; Fu, Peter P

    2014-01-01

    Pyrrolizidine alkaloids, produced by a large number of poisonous plants with wide global distribution, are associated with genotoxicity, tumorigenicity, and hepatotoxicity in animals and humans. Mammalian metabolism converts pyrrolizidine alkaloids to reactive pyrrolic metabolites (dehydropyrrolizidine alkaloids) that form covalent protein and DNA adducts. Although a mechanistic understanding is currently unclear, pyrrolizidine alkaloids can cause secondary (hepatogenous) photosensitization and induce skin cancer. In this study, the phototoxicity of monocrotaline, riddelliine, dehydromonocrotaline, dehydroriddelliine, and dehydroretronecine (DHR) in human HaCaT keratinocytes under ultraviolet A (UVA) irradiation was determined. UVA irradiation of HaCaT cells treated with dehydromonocrotaline, dehydroriddelline, and DHR resulted in increased release of lactate dehydrogenase and enhanced photocytotoxicity proportional to the UVA doses. UVA-induced photochemical DNA damage also increased proportionally with dehydromonocrotaline and dehydroriddelline. UVA treatment potentiated the formation of 8-hydroxy-2'-deoxyguanosine DNA adducts induced by dehydromonocrotaline in HaCaT skin keratinocytes. Using electron spin resistance trapping, we found that UVA irradiation of dehydromonocrotaline and dehydroriddelliine generates reactive oxygen species (ROS), including hydroxyl radical, singlet oxygen, and superoxide, and electron transfer reactions, indicating that cytotoxicity and genotoxicity of these compounds could be mediated by ROS. Our results suggest that dehydropyrrolizidine alkaloids formed or delivered to the skin cause pyrrolizidine alkaloid-induced secondary photosensitization and possible skin cancer.

  12. Looking beyond the perfect lens

    International Nuclear Information System (INIS)

    Wee, W H; Pendry, J B

    2010-01-01

    The holy grail of imaging is the ability to see through anything. From the conservation of energy, we can easily see that to see through a lossy material would require lenses with gain. The aim of this paper therefore is to propose a simple scheme by which we can construct a general perfect lens, with gain-one that can restore both the phases and amplitudes of near and far fields.

  13. Clear lens phacoemulsification in the anterior lenticonus due to Alport Syndrome: two case reports.

    Science.gov (United States)

    Aslanzadeh, Ghassem Amir; Gharabaghi, Davoud; Naderi, Niloofar

    2008-05-27

    Alport Syndrome has a prevalence of 1 case per 5,000 people and 85% of patients have the X-linked form, where affected males develop renal failure and usually have high-tone sensorineural deafness by age 20. The main abnormality is deficient synthesis of type IV collagen, the main component of basement membranes. Common ocular abnormalities of this syndrome consist of dot-and-fleck retinopathy, posterior polymorphous corneal dystrophy, and anterior lenticonus, but other ocular defects such as cataracts, posterior lenticonus, and retinal detachments have also been reported. We report two cases of anterior lenticonus due to Alport Syndrome and describe clear lens phacoemulsification and foldable intraocular lens implantation as an effective and safe refractive procedure in the four eyes of these two patients. All four eyes of the two patients were in good condition after surgery and achieved satisfactory optical and visual results and had no remarkable complications at six-months follow-up. Clear lens phacoemulsification with foldable intraocular lens implantation can be used as an efficient and safe procedure for vision disorders in these patients.

  14. Clear lens phacoemulsification in the anterior lenticonus due to Alport Syndrome: two case reports

    Directory of Open Access Journals (Sweden)

    Aslanzadeh Ghassem

    2008-05-01

    Full Text Available Abstract Introduction Alport Syndrome has a prevalence of 1 case per 5,000 people and 85% of patients have the X-linked form, where affected males develop renal failure and usually have high-tone sensorineural deafness by age 20. The main abnormality is deficient synthesis of type IV collagen, the main component of basement membranes. Common ocular abnormalities of this syndrome consist of dot-and-fleck retinopathy, posterior polymorphous corneal dystrophy, and anterior lenticonus, but other ocular defects such as cataracts, posterior lenticonus, and retinal detachments have also been reported. Case presentation We report two cases of anterior lenticonus due to Alport Syndrome and describe clear lens phacoemulsification and foldable intraocular lens implantation as an effective and safe refractive procedure in the four eyes of these two patients. Conclusion All four eyes of the two patients were in good condition after surgery and achieved satisfactory optical and visual results and had no remarkable complications at six-months follow-up. Clear lens phacoemulsification with foldable intraocular lens implantation can be used as an efficient and safe procedure for vision disorders in these patients.

  15. CONTACT LENS RELATED CORNEAL ULCER

    Directory of Open Access Journals (Sweden)

    AGARWAL P

    2010-01-01

    Full Text Available A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are:overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. The presenting symptoms of contact lens related corneal ulcers include eye discomfort, foreign body sensation and lacrimation. More serious symptoms are redness (especially circum-corneal injection, severe pain, photophobia, eye discharge and blurring of vision. The diagnosis is established by a thorough slit lamp microscopic examination with fluorescein staining and corneal scraping for Gram stain and culture of the infective organism. Delay in diagnosing and treatment can cause permanent blindness, therefore an early referral to ophthalmologist and commencing of antimicrobial therapy can prevent visual loss.

  16. Follow up of intraocular lens subluxation with a combined topographer/aberrometer

    OpenAIRE

    Georgios A. Kontadakis; George D. Kymionis; Vardhaman P. Kankariya; Ioannis G. Pallikaris

    2012-01-01

    Purpose: To report a 36-year-old patient with intraocular lens (IOL) subluxation that was followed for IOL stability with evaluation of images captured with the iTrace combined aberrometer/topographer. Methods: The patient had undergone phacoemulsification with IOL implantation for congenital cataract 15 years before. He presented with bilateral IOL subluxation, more severe in his right eye. Right eye was operated for IOL exchange and left eye was followed with the iTrace images. The image...

  17. Foldable toric intraocular lens for astigmatism correction in cataract patients.

    Science.gov (United States)

    Mendicute, Javier; Irigoyen, Cristina; Aramberri, Jaime; Ondarra, Ana; Montés-Micó, Robert

    2008-04-01

    To evaluate the results of AcrySof toric intraocular lens (IOL) (Alcon) implantation to correct preexisting astigmatism in patients having cataract surgery. Ophthalmology Service, Donostia Hospital, San Sebastián, Spain. This prospective observational study included 30 eyes of 15 consecutive patients with more than 1.00 diopter (D) of preexisting corneal astigmatism having cataract surgery. Bilateral implantation of the AcrySof toric IOL was performed after phacoemulsification. The uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere, residual keratometric and refractive cylinders, and toric IOL axis were measured. The UCVA was 20/40 or better in 93.3% of eyes and 20/25 or better in 66.6%. All eyes achieved 20/25 or better BCVA. The mean refractive cylinder decreased significantly after surgery from -2.34 D +/- 1.28 (SD) to -0.72 +/- 0.43 D (P<.01). Vector analysis of attempted versus achieved correction showed that 100% of eyes were within +/-1.00 D and 80% and 93.9% were within +/-0.50 D for J(0) and J(45), respectively. The mean toric IOL axis rotation was 3.63 +/- 3.11 degrees, with rotation less than 10 degrees in 96.7% of eyes. The results indicate that phacoemulsification and posterior chamber AcrySof toric IOL implantation is an effective option to correct preexisting astigmatism in cataract surgery. The AcrySof toric IOL showed good rotational stability.

  18. Microscopic analysis of an opacified OFT CRYL® hydrophilic acrylic intraocular lens

    Directory of Open Access Journals (Sweden)

    Bruna Vieira Ventura

    Full Text Available ABSTRACT A 51-year-old patient underwent posterior vitrectomy with perfluoropropane gas injection, phacoemulsification, and implantation of an Oft Cryl® hydrophilic acrylic intraocular lens (IOL because of traumatic retinal detachment and cataract in the right eye. On the first postoperative day, gas was filling the anterior chamber because of patient's non-compliance in terms of head positioning, and was reabsorbed within one week. Eight months later, the patient returned complaining of a significant decrease in vision. IOL opacification was noticed by slit-lamp examination. The lens was explanted to undergo gross and light microscopic analysis. The lens was also stained with the alizarin red method for calcium identification. Light microscopic analysis confirmed the presence of granular deposits, densely distributed in an overall circular pattern in the central part of the lens optic. The granules stained positive for calcium. This is the first case of the opacification of this type of hydrophilic lens. Surgeons should be aware of this potential postoperative complication, and the use of hydrophilic IOLs should be avoided in procedures involving intracameral gas because of the risk of IOL opacification.

  19. A case of Alagille syndrome complicated by intraocular lens subluxation and rhegmatogenous retinal detachment

    Directory of Open Access Journals (Sweden)

    Fukumoto M

    2013-07-01

    Full Text Available Masanori Fukumoto, Tsunehiko Ikeda, Tetsuya Sugiyama, Mari Ueki, Takaki Sato, Eisuke Ishizaki Department of Ophthalmology, Osaka Medical College, Takatsuki City, Japan Abstract: This case report describes a case of Alagille syndrome with developing intraocular lens subluxation and rhegmatogenous retinal detachment 4 years after cataract surgery. A 15-year-old female patient with Alagille syndrome-associated cataracts in both eyes underwent phacoemulsification aspiration and intraocular lens implantation. Four years postoperative, intraocular lens subluxation developed in her left eye. For treatment, extraction of the dislocated intraocular lens, anterior vitrectomy, and intraocular lens fixation was performed. Three weeks later, the patient developed rhegmatogenous retinal detachment, which was well-treated by pars plana vitrectomy. Cataract surgery needs to be performed carefully in patients with Alagille syndrome due to the weakness of the zonule of Zinn. Careful postoperative observation is necessary for patients with Alagille syndrome who have undergone intraocular surgery in order to facilitate early detection of a possible rhegmatogenous retinal detachment. Keywords: Alagille syndrome, cataract, retina, surgery

  20. Implantable Cardioverter Defibrillator

    Science.gov (United States)

    ... To Health Topics / Implantable Cardioverter Defibrillators Implantable Cardioverter Defibrillators Also known as What Is an Implantable Cardioverter ... pacemakers and defibrillators. Comparison of an Implantable Cardioverter Defibrillator and a Pacemaker The image compares an ICD ...

  1. Breast reconstruction - implants

    Science.gov (United States)

    Breast implants surgery; Mastectomy - breast reconstruction with implants; Breast cancer - breast reconstruction with implants ... to close the skin flaps. Breast reconstruction with implants is usually done in two stages, or surgeries. ...

  2. Research on one manual zoom liquid lens

    Science.gov (United States)

    Zhao, Cunhua; Shi, Yongpeng; Li, Wenjiao; Li, Congcong

    2011-11-01

    In liquid zoom lens, the accurate fixed-focus location needs the accurate calculation of focal length. That is to say, the accurate calculation of surface curvature must be obtained. Therefore, the research of their relation in liquid zoom lens becomes extremely important which has a directly theoretical instruction for the design of liquid zoom lenses. In our paper, the relation is studied. A manual liquid lens is reported which has upper and nether components with specificaton Φ12×5mm. The zoom lens is obtained by the upper component circumvolving down into the nether components.

  3. Numerical analyses of planer plasmonic focusing lens

    Science.gov (United States)

    Chou, Yen-Yu; Lee, Yeeu-Chang

    2018-03-01

    The use of polystyrene (PS) sphere lithography has been widely applied in the fabrication of micron and nano structures, due to their low cost and ease of fabrication in large scale applications. This study evaluated the feasibility of plasmonic lens base on metal thin films with nanohole structures fabricated by using PS sphere lithography through three-dimensional (3D) finite difference time domain (FDTD) method. We calculated the intensity profile of lens with various wavelength of incident light, lens size, cutting positions, diameters of nanohole, and periods of nanohole to investigate the geometric parameters influence on the focusing properties of the plasmonic lens.

  4. Exchange of tears under a contact lens is driven by distortions of the contact lens.

    Science.gov (United States)

    Maki, Kara L; Ross, David S

    2014-12-01

    We studied the flow of the post-lens tear film under a soft contact lens to understand how the design parameters of contact lenses can affect ocular health. When a soft contact lens is inserted, the blinking eyelid causes the lens to stretch in order to conform to the shape of the eye. The deformed contact lens acts to assume its un-deformed shape and thus generates a suction pressure in the post-lens tear film. In consequence, the post-lens tear fluid moves; it responds to the suction pressure. The suction pressure may draw in fresh fluid from the edge of the lens, or it may eject fluid there, as the lens reassumes its un-deformed shape. In this article, we develop a mathematical model of the flow of the post-lens tear fluid in response to the mechanical suction pressure of a deformed contact lens. We predict the amount of exchange of fluid exchange under a contact lens and we explore the influence of the eye's shape on the rate of exchange of fluid. © The Author 2014. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved. For permissions please email: journals.permissions@oup.com.

  5. A mechanistic study on the phototoxicity of atorvastatin: singlet oxygen generation by a phenanthrene-like photoproduct.

    Science.gov (United States)

    Montanaro, Sara; Lhiaubet-Vallet, Virginie; Iesce, MariaRosaria Iesce; Previtera, Lucio; Miranda, Miguel Angel

    2009-01-01

    Atorvastatin calcium (ATV) is one of the most frequently prescribed drugs worldwide. Among the adverse effects observed for this lipid-lowering agent, clinical cases of cutaneous adverse reactions have been reported and associated with photosensitivity disorders. Previous work dealing with ATV photochemistry has shown that exposure to natural sunlight in aqueous solution leads to photoproducts resulting from oxidation of the pyrrole ring and from cyclization to a phenanthrene derivative. Laser flash photolysis of ATV, at both 266 and 308 nm, led to a transient spectrum with two maxima at lambda= 360 and lambda= 580 nm (tau= 41 micro), which was assigned to the primary intermediate of the stilbene-like photocyclization. On the basis of the absence of a triplet-triplet absorption, the role of the parent drug as singlet oxygen photosensitizer can be discarded. By contrast, a stable phenanthrene-like photoproduct would be a good candidate to play this role. Laser flash photolysis of this compound showed a triplet-triplet transient absorption at lambdamax = 460 nm with a lifetime of 26 micro, which was efficiently quenched by oxygen (kq = 3 (+/-0.2) x 10(9) M(-1) s(-1)). Its potential to photosensitize formation of singlet oxygen was confirmed by spin trapping experiments, through conversion of TEMP to the stable free radical TEMPO. The photoreactivity of the phenanthrene-like photoproduct was investigated using Trp as a marker. The disappearance of the amino acid fluorescence (lambdamax = 340 nm) after increasing irradiation times at 355 nm was taken as a measurement of photodynamic oxidation. To confirm the involvement of a type II mechanism, the same experiment was also performed in D2O; this resulted in a significant enhancement of the reaction rate. On the basis of the obtained photophysical and photochemical results, the phototoxicity of atorvastatin can be attributed to singlet oxygen formation with the phenanthrene-like photoproduct as a photosensitizer.

  6. Synergic phototoxic effect of visible light or Gallium-Arsenide laser in the presence of different photo-sensitizers on Porphyromonas gingivalis and Fusobacterium nucleatum.

    Science.gov (United States)

    Ghanbari, Habibollah; Mousavi, Seyed Amir; Forouzanfar, Ali; Zakeri, Mahdi; Shafaee, Hooman; Shahnaseri, Shirin

    2015-01-01

    According to the development of resistant strains of pathogenic bacteria following treatment with antimicrobial chemotherapeutic agents, alternative approaches such as lethal photosensitization are being used. The aim of this study was to evaluate the effect of visible light and laser beam radiation in conjugation with three different photosensitizers on the survival of two main periodontopathogenic bacteria including Porphyromonas gingivalis and Fusobacterium nucleatum in different exposure periods. In this in vitro prospective study, strains of P. gingivalis and F. nucleatum. were exposed to visible light at wavelengths of 440 nm and diode laser light, Gallium-Arsenide, at wavelength of 830 nm in the presence of a photosensitizer (erythrosine, curcuma, or hydrogen peroxide). They were exposed 1-5 min to each light. Each experiment was repeated 3 times for each strain of bacteria. Data were analyzed by two-ways ANOVA and least significant difference post-hoc tests. P < 0.05 was considered as significant. After 4 days the colonies were counted. Viability of P. gingivalis was reduced 10% and 20% subsequent to exposure to visible light and diode laser, respectively. The values were 65% and 75% for F. nucleatum in a period of 5-min, respectively. Exposure to visible light or laser beam in conjugation with the photosensitizers suspension caused significant reduction in the number of P. gingivalis in duration of 5-min, suggesting a synergic phototoxic effect. However, the survival rate of F. nucleatum following the exposure to laser with hydrogen peroxide, erythrosine and rhizome of Curcuma longa (curcumin) after 5-min was 10%, 20% and 90% respectively. Within the limitations of this study, the synergic phototoxic effect of visible light in combination with each of the photosensitizers on P. gingivalis and F. nucleatum. However, the synergic phototoxic effect of laser exposure and hydrogen peroxide and curcumin as photosensitizers on F. nucleatum was not shown.

  7. Cochlear Implants

    Science.gov (United States)

    ... For young children who are deaf or severely hard-of-hearing, using a cochlear implant while they are young exposes them to sounds during an optimal period to develop speech and language skills. Research has shown that when these children receive ...

  8. Bilateral intraocular lens subluxation secondary to haptic angulation.

    Science.gov (United States)

    Moreno-Montañés, Javier; Fernández-Hortelano, Ana; Caire, Josemaría

    2008-04-01

    An 82-year-old man had uneventful phacoemulsification with bilateral implantation of a hydrophilic acrylic, single-piece intraocular lens (IOL) (ACR6D SE, Laboratoires Cornéal). Five years later, simultaneous and bilateral IOL subluxations occurred. In both eyes, the subluxation was situated on the side of one haptic that had moved forward (temporal area in the right eye and superior area in the left eye). In the right eye, the haptic-capsular bag was entrapped by the pupil and produced endothelial damage. A transscleral suture was placed over and under the subluxated haptic through the anterior and posterior capsules to capture the haptic. The haptic was then sutured to the sclera. No postoperative complications developed. We hypothesize that 10-degree angulated and broad haptic junctions can lead to zonular damage and IOL subluxation.

  9. [Acanthamoeba isolation from contact lens solution of contact lens wearers without keratitis].

    Science.gov (United States)

    Watanabe, R; Ishibashi, Y; Hommura, S; Ishii, K

    1994-05-01

    Acanthamoeba keratitis seems to be associated with wearing contact lenses. As controls, we surveyed contact lens wearers without keratitis. Contact lens solutions of 93 persons were examined in order to identify risk factors for contamination by Acanthamoeba. Therefore, the contact lens disinfection system and storage schedules were studied in each case. Acanthamoeba organisms were isolated from 4 specimens (4.3%). The incidence of Acanthamoeba was higher in specimens of soft contact lens solution than in those of hard contact lens solution, and all the Acanthamoeba positive cases had been using tap water.

  10. Lens parameters as predictors of intraocular pressure changes after phacoemulsification.

    Science.gov (United States)

    Moghimi, S; Abdi, F; Latifi, G; Fakhraie, G; Ramezani, F; He, M; Lin, S C

    2015-11-01

    To evaluate intraocular pressure (IOP) change after cataract surgery in non-glaucomatous eyes with narrow and open angles (OAs) and its relation to novel lens parameters measured by anterior segment optical coherence tomography (AS-OCT). University affiliated hospital, Farabi Eye Hospital, Tehran, Iran. Prospective interventional case series. In this prospective study, 85 non-glaucomatous eyes underwent phacoemulsification and lens implantation. Thirty-nine eyes had OAs and 46 eyes had narrow angles (NAs). IOP and biometric parameters were measured by AS-OCT preoperatively and 3 months after surgery. Change in IOP and its relation to biometric parameters, including lens vault (LV), anterior vault (AV), defined as the sum of the LV and the ACD, and relative LV (rLV), defined as the ratio of the LV to the AV, were evaluated. The main outcome measure was degree of IOP change after phacoemulsification. Of the 85 patients included in the analysis, 35 were male and 50 were female with an overall mean age of 62.2 ± 8.9 years. The average IOP reduction was -4.95 ± 2.26 mm Hg, from a preoperative mean of 17.12 ± 2.47 mm Hg, at 3 months after cataract surgery. The amount of IOP reduction was significantly greater in the NA compared with the OA group. In multivariate linear regression analysis, preoperative IOP and AV were significantly associated with IOP decrease (all ≤ 0.03). Cataract surgery results in IOP reduction in both OA and NA eyes. The amount of IOP reduction is related to AV.

  11. Protection of the eye lens

    International Nuclear Information System (INIS)

    2015-01-01

    The limit of radiation exposure for eye lens is going to decrease dramatically from 150 to 20 mSv as a transposition into the French law of a CIPR (International Commission for Radiation Protection) directive. Sanitary studies have shown that radiologists are more likely by a factor of 3.8 to get eye lens opacities than the rest of the population. The wearing of protective glasses is recommended and in order to get a better monitoring of the radiation dose new dosimeters have been designed, they can be worn on the glass frame of directly stuck on the skin near the eyes. A study has shown that veterinary surgeons that are accustomed to stay near animals to keep them quiet during radiological exams are prone to receive high doses as well as physicians that use hypnosis to decrease the level of anxiety of their patients during radiological exams. Radiation exposure of radiologists can be mitigated through: the use of protective shields and equipment and the optimization of the dose delivered to the patient. (A.C.)

  12. Bioptics in sutureless intrascleral multifocal posterior chamber intraocular lens fixation.

    Science.gov (United States)

    Pavlidis, Mitrofanis; de Ortueta, Diego; Scharioth, Gabor B

    2011-05-01

    To present a technique for sutureless fixation of a three-piece, multifocal, posterior chamber intraocular lens (IOL) in the ciliary sulcus. A 24-year-old woman presented with bilateral subluxation of the crystalline lens. Two straight sclerotomies were prepared with a 24-gauge cannula 2.0 mm from the limbus 180° apart from each other. The cannula was used to create a 2.0- to 3.0-mm tunnel parallel to the limbus starting from the sclerotomies. The leading haptic of the multifocal IOL was grasped at its tip with end-gripping, 25-gauge forceps and pulled through the sclerotomy. The forceps was used to introduce the IOL haptic into the scleral tunnel parallel to the limbus. Multifocal posterior chamber IOLs were stable and well centered. No postoperative complications occurred in the 16-month follow-up period. Preoperative astigmatism was corrected after IOL implantation with corneal wavefront-guided laser epithelial keratomileusis. Sutureless fixation of multifocal posterior chamber IOL haptics in a scleral tunnel parallel to the limbus can be successful, resulting in long-term centration and three-dimensional axial stability for optimal refractive results. If necessary, postoperative wavefront-guided refractive correction can be performed to optimize final refraction. Copyright 2011, SLACK Incorporated.

  13. Intraocular lens dislocation after whole-body vibration.

    Science.gov (United States)

    Vela, José I; Andreu, David; Díaz-Cascajosa, Jesús; Buil, José A

    2010-10-01

    We present 2 cases of intraocular lens (IOL) dislocation that appeared shortly after the patients exercised on a vibration platform. The first patient was a 71-year-old woman who presented with lens subluxation in her right eye and a complete posterior IOL dislocation in her left eye. The second case was a 62-year-old woman who presented with unilateral IOL dislocation within the capsular bag in her right eye. Timing from IOL implantation to dislocation was approximately 6 years and 4 years, respectively. Pars plana vitrectomy with removal of the dislocated IOL was performed in both patients. Whole-body vibration training has become increasingly popular as a form of exercise training. It reportedly may provide benefits in physical function and in some diseases, especially in older people. However, evidence-based protocols ensuring safety and efficacy in this population are lacking. We discuss vibration as a cause of late IOL dislocation. Copyright © 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. Color corrected Fresnel lens for solar concentration

    International Nuclear Information System (INIS)

    Kritchman, E.M.

    1979-01-01

    A new linear convex Fresnel lens with its groove side down is described. The design philosophy is similar to the highly concentrating two focal Fresnel lens but including a correction for chromatic aberration. A solar concentration ratio as high as 80 is achieved. For wide acceptance angles the concentration nears the theoretical maximum. (author)

  15. Modified suturing contact lens for penetrating keratoplasty.

    Science.gov (United States)

    Kramer, S G; Stewart, H L

    1978-11-01

    The authors have previously described a suturing contact lens that protects the corneal endothelium by aiding in the maintenance of the anterior chamber during penetrating keratoplasty. This report describes structural modifications of the suturing contact lens, which improve its stability and effectiveness. An additional configuration for use in corneal lacerations is presented.

  16. Charged black lens in de Sitter space

    Science.gov (United States)

    Tomizawa, Shinya

    2018-02-01

    We obtain a charged black lens solution in the five-dimensional Einstein-Maxwell-Chern-Simons theory with a positive cosmological constant. It is shown that the solution obtained here describes the formation of a black hole with the spatial cross section of a sphere from that of the lens space of L (n ,1 ) in five-dimensional de Sitter space.

  17. Contact Lens Use in the Civil Airman Population

    National Research Council Canada - National Science Library

    Nakagawara, Van

    2002-01-01

    ...) aeromedical certificate. Although contact lens technology has advanced dramatically in recent years, the aviation environment may still have adverse effects on contact lens performance in some flight situations...

  18. Corrected electrostatic lens systems for ion beams

    International Nuclear Information System (INIS)

    Dalgish, R.L.

    1981-01-01

    Recent work in our laboratory has introduced a new class of electrostatic focus forming element for beams, the ELCO lens. It compares favourably with the electrostatic and magnetic quadrupole elements conventionally used for microbeam formation. The ELCO lens does however have disadvantages associated with apertures and alignment. We have continued with the development of ion beam lenses and have evolved a further class of lens element which eliminates aperture and alignment problems. This new element can be combined like optical lenses into an aberration corrected system. Experimental measurement on the basic lens element has confirmed mathematical analysis of ion trajectories through the element. This mathematical analysis predicts that the basic element can be combined into a corrected lens system for, either: (1) high resolution microprobe formation with intrinsic rastering ability, the spot size limited only by the beam properties; or (2) high quality image formation with large magnification/demagnification ratio and wide angular aperture. (orig.)

  19. Short Implants: New Horizon in Implant Dentistry

    Science.gov (United States)

    Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-01-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration. PMID:27790598

  20. Short Implants: New Horizon in Implant Dentistry.

    Science.gov (United States)

    Jain, Neha; Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-09-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration.

  1. Investigation of lens morphology and mechanical characteristics of lens capsule and lens nucleus in patients with agerelated and diabetic cataract

    Directory of Open Access Journals (Sweden)

    A. S. Tishkova

    2014-07-01

    Full Text Available Purpose: To investigate the influence of carbohydrate metabolism on the structure and mechanical properties of the lens capsule and nucleus.Methods: Human lens pathology was studied in different forms of cataract. 220 patients with a cataract (220 eyes were included in this study. Morphological, immunohystological and immunocytochemical investigations of lens substance (antibodies to a- (a-А and a-В, b-, g- crystallines, spectroscopic analyses of smears and morphometric analyses of slices, investigation of lens morphology and mechanical caracteristics of lens capsule and lens nucleus were performed.Results: The capsule of the lens in patients with senile cataract contains more Na+, Cl-. The capsule of the lens in patients with senile cataract contains more Ca2+, O. Mechanical strength of the capsule in the case of diabetes mellitus was lower comparatively with senile cataract in the same age groups. More significant expression of a-В and b-crystallines was found in patients with diabetes mellitus comparatively with patients with age-related cataract. Morphological features were founded in patients with cortical and nuclear forms of senile cataract and the diabetic cataract.Conclusion: During surgery (ultrasonic microcoaxial phacoemulsification the equivalent of ultrasound was recorded. Lower density of the lens nucleus of patients with diabetes mellitus made it possible to use lower energy parameters. Using the torsion ultrasound in those cases allowed us to decrease the influence of ultrasound on eye tissues and reduce the time of achieving the maximum BCVA in the postsurgical period.

  2. Investigation of lens morphology and mechanical characteristics of lens capsule and lens nucleus in patients with agerelated and diabetic cataract

    Directory of Open Access Journals (Sweden)

    A. S. Tishkova

    2013-01-01

    Full Text Available Purpose: To investigate the influence of carbohydrate metabolism on the structure and mechanical properties of the lens capsule and nucleus.Methods: Human lens pathology was studied in different forms of cataract. 220 patients with a cataract (220 eyes were included in this study. Morphological, immunohystological and immunocytochemical investigations of lens substance (antibodies to a- (a-А and a-В, b-, g- crystallines, spectroscopic analyses of smears and morphometric analyses of slices, investigation of lens morphology and mechanical caracteristics of lens capsule and lens nucleus were performed.Results: The capsule of the lens in patients with senile cataract contains more Na+, Cl-. The capsule of the lens in patients with senile cataract contains more Ca2+, O. Mechanical strength of the capsule in the case of diabetes mellitus was lower comparatively with senile cataract in the same age groups. More significant expression of a-В and b-crystallines was found in patients with diabetes mellitus comparatively with patients with age-related cataract. Morphological features were founded in patients with cortical and nuclear forms of senile cataract and the diabetic cataract.Conclusion: During surgery (ultrasonic microcoaxial phacoemulsification the equivalent of ultrasound was recorded. Lower density of the lens nucleus of patients with diabetes mellitus made it possible to use lower energy parameters. Using the torsion ultrasound in those cases allowed us to decrease the influence of ultrasound on eye tissues and reduce the time of achieving the maximum BCVA in the postsurgical period.

  3. Antibacterial Actions and Potential Phototoxic Effects of Volatile oils of Foeniculum sp. (fennel, Salvia sp. (sage, Vitis sp. (grape, Lavandula sp. (lavender

    Directory of Open Access Journals (Sweden)

    Elif Ayse Erdogan Eliuz

    2016-09-01

    Full Text Available In the present study, the volatile compounds of essential oil of Foeniculum vulgare (fennel, Salvia officinalis (sage, Vitis vinifera (grape, Lavandula angustifolia (lavender were analysed by gas chromatography-mass spectrometry (GC-MS using the Nist and Willey libraries. It was determined that the main components of Foeniculum sp. were anethole (41.11%, carvacrol (9.18%. whereas main components of Salvia sp were 1.8 cineole (34.09%, caryophyllene (10.95%, camphor (9.44%, α-pinene (8.42%. Vitis sp. contained linoleic acid (36.98%, 2,4-decadienal (30.79%. Finally, volatile component of Lavandula sp. was linalool (33.57%, linalyl acetate (30.74%. Photoxic antibacterial activity of volatile oil of those plants against Escherichia coli (ATCC 25293, Klebsiella pneumoniae (10031, Salmonella thyphimurium, Bacillus subtilis (ATCC 6633, Staphylococcus aureus (ATCC 25925, Enterococcus feacalis (ATCC 29212 were examined by using disc diffusion method. We demonstrated that volatile oil effectively can be activated by a standard LED light. In vitro, significant phototoxicity was demonstrated by volatile oil of Foeniculum sp. and Vitis sp. (P < 0.05, while minor phototoxicity was induced by Lavandula sp. Therefore, volatile oil of plant can be considered as a potential photosensitizer in the photochemical therapy.

  4. Cuba Through A New Lens

    Directory of Open Access Journals (Sweden)

    Jean Stubbs

    2008-12-01

    Full Text Available [First paragraph] The Origins of the Cuban Revolution Reconsidered. Samuel Farber. Chapel Hill: University of North Carolina Press, 2006. x + 212 pp. (Paper US$ 19.95 Cuba: A New History. Ric hard Gott . New Haven: Yale University Press, 2005. xii + 384 pp. (Paper US$ 17.00 Havana: The Making of Cuban Culture. Antoni Kapcia. Oxford: Berg Publishers, 2005. xx + 236 pp. (Paper US$ 24.95 Richard Gott, Antoni Kapcia, and Samuel Farber each approach Cuba through a new lens. Gott does so by providing a broad-sweep history of Cuba, which is epic in scope, attaches importance to social as much as political and economic history, and blends scholarship with flair. Kapcia homes in on Havana as the locus for Cuban culture, whereby cultural history becomes the trope for exploring not only the city but also Cuban national identity. Farber revisits his own and others’ interpretations of the origins of the Cuban Revolution.

  5. Radiation studies in Lens culinaris

    International Nuclear Information System (INIS)

    Sinha, S.S.N.

    1977-01-01

    Estimation of chromosomal aberrations in flowers of Lens culinaris according to their sequence of development in the plants at 4, 8 and 12 Kr in the M 1 generation, showed that the later formed flowers had smaller percentages of cells with aberrations than those developed earlier. It is suggested that this may be the result of competition between more damaged and less damaged cells during the development of the shoot. There is consequently a decrease of sterility in successive flowers. The numbers of karyotypes taking part in the formation of lower and uppermost flowers were estimated cytologically at 4, 8 and 12 Kr. It was found that more karyotypes were involved in the formation of the lower flowers than in the upper ones. It appeared that at lower doses larger numbers of karyotypes were taking part in the formation of the chimaera than at higher doses. (auth.)

  6. The PARP inhibitor PJ-34 sensitizes cells to UVA-induced phototoxicity by a PARP independent mechanism

    International Nuclear Information System (INIS)

    Lakatos, Petra; Hegedűs, Csaba; Salazar Ayestarán, Nerea; Juarranz, Ángeles; Kövér, Katalin E.; Szabó, Éva; Virág, László

    2016-01-01

    Highlights: • PARP-1 is not a key regulator of photochemotherapy. • The PARP inhibitor PJ-34 sensitizes cells to UVA-induced phototoxicity by a PARP independent mechanism. • Photosensitization by PJ-34 is associated with increased ROS production and DNA damage. • Cells sensitized by PJ-34 undergo caspase-mediated apoptosis. - Abstract: A combination of a photosensitizer with light of matching wavelength is a common treatment modality in various diseases including psoriasis, atopic dermatitis and tumors. DNA damage and production of reactive oxygen intermediates may impact pathological cellular functions and viability. Here we set out to investigate the role of the nuclear DNA nick sensor enzyme poly(ADP-ribose) polymerase 1 in photochemical treatment (PCT)-induced tumor cell killing. We found that silencing PARP-1 or inhibition of its enzymatic activity with Veliparib had no significant effect on the viability of A431 cells exposed to 8-methoxypsoralen (8-MOP) and UVA (2.5 J/cm 2 ) indicating that PARP-1 is not likely to be a key player in either cell survival or cell death of PCT-exposed cells. Interestingly, however, another commonly used PARP inhibitor PJ-34 proved to be a photosensitizer with potency equal to 8-MOP. Irradiation of PJ-34 with UVA caused changes both in the UV absorption and in the 1H NMR spectra of the compound with the latter suggesting UVA-induced formation of tautomeric forms of the compound. Characterization of the photosensitizing effect revealed that PJ–34 + UVA triggers overproduction of reactive oxygen species, induces DNA damage, activation of caspase 3 and caspase 8 and internucleosomal DNA fragmentation. Cell death in this model could not be prevented by antioxidants (ascorbic acid, trolox, glutathione, gallotannin or cell permeable superoxide dismutase or catalase) but could be suppressed by inhibitors of caspase-3 and −8. In conclusion, PJ-34 is a photosensitizer and PJ–34 + UVA causes DNA damage and caspase

  7. Excited-State Dynamics of the Thiopurine Prodrug 6-Thioguanine: Can N9-Glycosylation Affect Its Phototoxic Activity?

    Directory of Open Access Journals (Sweden)

    Brennan Ashwood

    2017-02-01

    Full Text Available 6-Thioguanine, an immunosuppressant and anticancer prodrug, has been shown to induce DNA damage and cell death following exposure to UVA radiation. Its metabolite, 6-thioguanosine, plays a major role in the prodrug’s overall photoreactivity. However, 6-thioguanine itself has proven to be cytotoxic following UVA irradiation, warranting further investigation into its excited-state dynamics. In this contribution, the excited-state dynamics and photochemical properties of 6-thioguanine are studied in aqueous solution following UVA excitation at 345 nm in order to provide mechanistic insight regarding its photochemical reactivity and to scrutinize whether N9-glycosylation modulates its phototoxicity in solution. The experimental results are complemented with time-dependent density functional calculations that include solvent dielectric effects by means of a reaction-field solvation model. UVA excitation results in the initial population of the S2(ππ* state, which is followed by ultrafast internal conversion to the S1(nπ* state and then intersystem crossing to the triplet manifold within 560 ± 60 fs. A small fraction (ca. 25% of the population that reaches the S1(nπ* state repopulates the ground state. The T1(ππ* state decays to the ground state in 1.4 ± 0.2 μs under N2-purged conditions, using a 0.2 mM concentration of 6-thioguanine, or it can sensitize singlet oxygen in 0.21 ± 0.02 and 0.23 ± 0.02 yields in air- and O2-saturated solution, respectively. This demonstrates the efficacy of 6-thioguanine to act as a Type II photosensitizer. N9-glycosylation increases the rate of intersystem crossing from the singlet to triplet manifold, as well as from the T1(ππ* state to the ground state, which lead to a ca. 40% decrease in the singlet oxygen yield under air-saturated conditions. Enhanced vibronic coupling between the singlet and triplet manifolds due to a higher density of vibrational states is proposed to be responsible for the observed

  8. The PARP inhibitor PJ-34 sensitizes cells to UVA-induced phototoxicity by a PARP independent mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Lakatos, Petra; Hegedűs, Csaba [Department of Medical Chemistry, Faculty of Medicine, University of Debrecen, Debrecen (Hungary); Salazar Ayestarán, Nerea; Juarranz, Ángeles [Department of Biology, Faculty of Sciences, Universidad Autónoma of Madrid, 28049-Madrid (Spain); Kövér, Katalin E. [Department of Inorganic and Analytical Chemistry, Faculty of Sciences, University of Debrecen, Debrecen (Hungary); Szabó, Éva [Department of Dermatology, Faculty of Medicine, University of Debrecen, Debrecen (Hungary); Virág, László, E-mail: lvirag@med.unideb.hu [Department of Medical Chemistry, Faculty of Medicine, University of Debrecen, Debrecen (Hungary); MTA-DE Cell Biology and Signaling Research Group, Debrecen (Hungary)

    2016-08-15

    Highlights: • PARP-1 is not a key regulator of photochemotherapy. • The PARP inhibitor PJ-34 sensitizes cells to UVA-induced phototoxicity by a PARP independent mechanism. • Photosensitization by PJ-34 is associated with increased ROS production and DNA damage. • Cells sensitized by PJ-34 undergo caspase-mediated apoptosis. - Abstract: A combination of a photosensitizer with light of matching wavelength is a common treatment modality in various diseases including psoriasis, atopic dermatitis and tumors. DNA damage and production of reactive oxygen intermediates may impact pathological cellular functions and viability. Here we set out to investigate the role of the nuclear DNA nick sensor enzyme poly(ADP-ribose) polymerase 1 in photochemical treatment (PCT)-induced tumor cell killing. We found that silencing PARP-1 or inhibition of its enzymatic activity with Veliparib had no significant effect on the viability of A431 cells exposed to 8-methoxypsoralen (8-MOP) and UVA (2.5 J/cm{sup 2}) indicating that PARP-1 is not likely to be a key player in either cell survival or cell death of PCT-exposed cells. Interestingly, however, another commonly used PARP inhibitor PJ-34 proved to be a photosensitizer with potency equal to 8-MOP. Irradiation of PJ-34 with UVA caused changes both in the UV absorption and in the 1H NMR spectra of the compound with the latter suggesting UVA-induced formation of tautomeric forms of the compound. Characterization of the photosensitizing effect revealed that PJ–34 + UVA triggers overproduction of reactive oxygen species, induces DNA damage, activation of caspase 3 and caspase 8 and internucleosomal DNA fragmentation. Cell death in this model could not be prevented by antioxidants (ascorbic acid, trolox, glutathione, gallotannin or cell permeable superoxide dismutase or catalase) but could be suppressed by inhibitors of caspase-3 and −8. In conclusion, PJ-34 is a photosensitizer and PJ–34 + UVA causes DNA damage and caspase

  9. Microbial contamination of contact lens storage cases and domestic tap water of contact lens wearers.

    Science.gov (United States)

    Üstüntürk, Miray; Zeybek, Zuhal

    2012-11-01

    Contact lenses have been widely used as an alternative to spectacles both in developed and developing countries. However, under certain circumstances, adverse responses can occur during contact lens wear and several microorganisms--including bacteria, fungi, and free living amoebae--can cause several eye infections in wearers. Extended wear of contact lenses is the major risk factor of eye infections such as microbial keratitis, besides contaminated contact lens storage case, contaminated lens care solutions, and inaccurate contact lens handling. In this study, we collected contact lens storage case and domestic tap water samples from 50 asymptomatic contact lens wearers. We determined that total aerobic mesophilic bacteria were isolated in 45 (90 %), Gram negative rod bacteria were isolated in 20 (40 %), Pseudomonas spp. were isolated in 2 (4 %) and fungi were isolated in 18 (36 %) out of 50 contact lens storage cases. Free living amoebae were not detected in investigated contact lens storage cases. At the same time, out of 50, total aerobic mesophilic bacteria were isolated in 34 (68 %), fungi were isolated in 15 (30 %) and free living amoebae were isolated in 15 (30 %) domestic tap water samples. No Gram-negative rod bacteria and Pseudomonas spp. were detected in investigated water samples. Two contact lens case samples and two tap water samples were excluded from the analysis for Pseudomonas spp. for technical reasons. According to our findings, inadequate contact lens maintenance during lens wear may result in the contamination of contact lens storage cases. This situation can lead to severe eye infections in contact lens wearers over time.

  10. Intracorneal Ring Segments Implantation for Corneal Ectasia.

    Science.gov (United States)

    Giacomin, Natalia T; Mello, Glauco R; Medeiros, Carla S; Kiliç, Alyin; Serpe, Cristine C; Almeida, Hirlana G; Kara-Junior, Newton; Santhiago, Marcony R

    2016-12-01

    To provide an overview of the predictability, safety, and efficacy of intrastromal corneal ring segment (ICRS) implantation as a tool to improve visual acuity and its association with other techniques such as corneal collagen cross-linking (CXL), addressing biomechanical outcomes, models, surgical planning and technique, indications, contraindications, and complications in ectatic corneas. Literature review. ICRSs have been used to regularize the corneal shape and reduce corneal astigmatism and higher order aberrations, improve visual acuity to acceptable limits, and delay, or eventually prevent, a corneal keratoplasty in keratoconic eyes. Changes in ICRS thickness and size, combination of techniques, and the addition of femtosecond lasers to dissect more foreseeable channels represent an improvement toward more predictable results. Several studies have shown, over time, the long-term efficacy and safety of ICRS treatment for keratoconus, with variable predictability, maintaining the early satisfactory outcomes regarding visual acuity, keratometry, and corneal thickness. It is just as important to ensure that the disease will not progress as it is to improve the visual acuity. Therefore, many studies have shown combined techniques using ICRS implantation and CXL. Also, further limitations of ICRS implantation can be addressed when associated with phakic intraocular lens implantation and photorefractive keratectomy. ICRS implantation has shown effectiveness and safety in most cases, including combined procedures. In properly selected eyes, it can improve both refraction and vision in patients with keratoconus. [J Refract Surg. 2016;32(12):829-839.]. Copyright 2016, SLACK Incorporated.

  11. Aphakia correction with retropupillary fixated iris-claw lens (Artisan – long-term results

    Directory of Open Access Journals (Sweden)

    Schallenberg M

    2013-12-01

    Full Text Available Maurice Schallenberg,1,2 Dirk Dekowski,1 Angela Hahn,1 Thomas Laube,1,3 Klaus-Peter Steuhl,1 Daniel Meller11Department of Ophthalmology, University Hospital Essen, University of Duisburg-Essen, Essen, Germany; 2HELIOS Klinikum Wuppertal, Wuppertal, Germany; 3Zentrum für Augenheilkunde PD Dr Laube, Düsseldorf, GermanyPurpose: To evaluate the technique, safety, and efficacy of the retropupillary implantation of iris-claw intraocular lenses in a long-term follow-up study.Patients and methods: This retrospective study included 31 eyes of 31 patients who underwent an Artisan aphakic intraocular lens implantation between January 2006 and February 2011 at the University Hospital Essen, Essen, Germany and at the Zentrum für Augenheilkunde PD Dr Laube, Düsseldorf, Germany. Preoperative data collected included demographics, etiology of aphakia, previous surgeries, preoperative eye pathology, intraocular pressure, clinical signs of endothelial cell loss, and best corrected visual acuity. Operative data and postoperative outcomes included the best corrected visual acuity, lens position, intraocular pressure, pigment dispersion, clinical signs of endothelial cell loss, development of macular edema, and other complications.Results: Thirty-one patients were included. The mean follow-up was 25.2 months (range: 4–48 months. The mean best corrected visual acuity postoperatively was 0.64 logarithm of the minimum angle of resolution (logMAR and varied from 0 logMAR to 3 logMAR. Some patients had a low visual acuity preoperatively because of preoperative eye pathologies. In 22 patients the visual acuity improved, in two patients the visual acuity remained unchanged, and seven patients showed a decreased visual acuity. Complications were peaked pupils (n=10 and retinal detachment in one case. Four patients showed an iris atrophy and high intraocular pressure was observed only in one patient. Subluxation of the intraocular lens, endothelial cell loss, and

  12. Implantation, recoil implantation, and sputtering

    International Nuclear Information System (INIS)

    Kelly, R.

    1984-01-01

    Underlying ion-beam modification of surfaces is the more basic subject of particle-surface interaction. The ideas can be grouped into forward and backward features, i.e. those affecting the interior of the target and those leading to particle expulsion. Forward effects include the stopping of the incident particles and the deposition of energy, both governed by integral equations which are easily set up but difficult to solve. Closely related is recoil implantation where emphasis is placed not on the stopping of the incident particles but on their interaction with target atoms with resulting implantation of these atoms. Backward effects, all of which are denoted as sputtering, are in general either of collisional, thermal, electronic, or exfoliational origin. (Auth.)

  13. Contact lens compliance among a group of young, university-based lens users in South India.

    Science.gov (United States)

    Noushad, Babu; Saoji, Yeshwant; Bhakat, Premjit; Thomas, Jyothi

    2012-01-01

    To investigate the rate of compliance with the soft contact lens care and maintenance procedures with a focus on contact lens wearing habits, cleaning and disinfecting procedures, and maintenance of lens care accessories in a group of young, university-based contact lens wearers Two hundred and sixteen young soft contact lens wearers with an age range of 18-22 years were selected conveniently from the student population of Manipal University, Manipal, India. After receiving informed consent from the participants, their level of compliance with contact lenses was assessed using a questionnaire. The mean (±SD) age of the participants was 21.86±2.35 years. Out of 216 subjects, only 34% of the lens users were identified to be compliant with the least level of compliance observed in the maintenance of lens care accessories. Conventional users showed significantly (p=0.001) better level of compliance compared to disposable wearers and so did the users who acquired their lenses from clinicians (p=0.001) compared to over-the-counter lens receipt. The gender (p=0.496) and years of experience in contact lens use (p=0.142) did not show any statistically significant difference in the level of compliance. This study demonstrated that non-compliance with lens care procedures among a group of young, university-based soft contact lens wearers is common. The results indicated that all subjects had some degree of non-compliance and the least level of compliance observed in the care of lens accessories.

  14. Tear film physiology and contact lens wear. II. Contact lens-tear film interaction.

    Science.gov (United States)

    Holly, F J

    1981-04-01

    The successful fitting of contact lenses requires the practitioner to take into account many properties of the specific lens type used but the practitioner must also understand patient factors including tear properties, use of appropriate solutions, procedures for lens cleaning, and efficiency of blinking. Selection of appropriate patients, selection of lens type, proper fitting, good maintenance, and training and monitoring of patients increase the probability of achieving success.

  15. Cochlear Implant

    Directory of Open Access Journals (Sweden)

    Mehrnaz Karimi

    1993-03-01

    Full Text Available People with profound hearing loss are not able to use some kinds of conventional amplifiers due to the nature of their loss. In these people, hearing sense is stimulated only when the auditory nerve is activated via electrical stimulation. This stimulation is possible through cochlear implant. In fact, for the deaf people who have good mental health and can not use surgical and medical treatment and also can not benefit from air and bone conduction hearing aids, this device is used if they have normal central auditory system. The basic parts of the device included: Microphone, speech processor, transmitter, stimulator and receiver, and electrode array.

  16. Cochlear Implant

    Directory of Open Access Journals (Sweden)

    Mehrnaz Karimi

    1992-04-01

    Full Text Available People with profound hearing loss are not able to use some kinds of conventional amplifiers due to the nature of their loss . In these people, hearing sense is stimulated only when the auditory nerve is activated via electrical stimulation. This stimulation is possible through cochlear implant. In fact, for the deaf people who have good mental health and can not use surgical and medical treatment and also can not benefit from air and bone conduction hearing aids, this device is used if they have normal central auditory system. The basic parts of the device included: Microphone, speech processor, transmitter, stimulator and receiver, and electrode array.

  17. Placement of a crystalline lens and intraocular lens: Retinal image quality.

    Science.gov (United States)

    Siedlecki, Damian; Nowak, Jerzy; Zajac, Marek

    2006-01-01

    The influence of changes of both crystalline lens and intraocular lens (IOL) misalignment on the retinal image quality was investigated. The optical model of the eye used in investigations was the Liou-Brennan model, which is commonly considered as one of the most anatomically accurate. The original crystalline lens from this model was replaced with an IOL, made of rigid polymethylmethacrylate, in a way that recommend obligatory procedures. The modifications that were made both for crystalline lens and IOL were the longitudinal, the transversal, and the angular displacement.

  18. Restoring lens capsule integrity enhances lens regeneration in New Zealand albino rabbits and cats.

    Science.gov (United States)

    Gwon, A; Gruber, L J; Mantras, C

    1993-11-01

    In studies conducted by numerous investigators for 150 years, lenses regenerated following endocapsular lens extraction in New Zealand albino rabbits have been irregular in shape, appearing primarily doughnut-shaped as a result of lack of lens growth at the site of the anterior capsulotomy and its adhesion to the posterior capsule. In the present study, we restored the lens capsule integrity by inserting a collagen patch at the time of surgery to seal the anterior capsulotomy and to improve the shape and structure of the regenerated lenses. We then filled the capsule bag with air to prevent adhesions between the anterior and posterior capsule and maintain capsule tautness and shape. Lens regeneration was first noted as early as one to two weeks. Regenerated lens filled approximately 50% of the capsule bag at two weeks and 100% by five weeks. Subsequent growth was in the anterior-posterior direction and measured by A-scan biometry. Lens thickness increased by 0.3 mm per month. The regenerated lenses were spherical with normal cortical structure and a nuclear opacity. In conclusion, restoration of lens capsular integrity with a collagen patch following endocapsular lens extraction enhanced the shape, structure, and growth rate of the regenerated lenses. In addition, lens regeneration was shown to occur in two cats.

  19. Development of Fresnel lens for improvement of rear visibility; Shikai kojo Fresnel lens no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Iwamoto, K.; Sanada, C.; Tsukino, M. [Nissan Motor Co. Ltd., Tokyo (Japan)

    1997-10-01

    Fresnel lenses have been widely used to increase the visual field around vehicles for drivers. However, internal reflection in these lenses has been an obstacle in producing dear images. This internal glow is generated by incident light from an unexpected direction reflecting on the non-lens surface or radiating from the non-lens surface of the Fresnel lens. The cause of internal glow has been made dear combining louver film with the lens. The newly developed technology removes obstacles in producing dear images by reducing internal glow. 7 figs.

  20. Night Vision Goggles Objectives Lens Focusing Methodology

    National Research Council Canada - National Science Library

    Pinkus, Alan; Task, H. L

    2000-01-01

    ...: interpupillary distance, tilt, eye relief, height, eyepiece and objective lens focus. Currently, aircrew use a Hoffman 20/20 test unit to pre-focus their NVG objective lenses at optical infinity before boarding their aircraft...

  1. Role of Aquaporin 0 in lens biomechanics

    Energy Technology Data Exchange (ETDEWEB)

    Sindhu Kumari, S.; Gupta, Neha [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); Shiels, Alan [Washington University School of Medicine, St. Louis, MO (United States); FitzGerald, Paul G. [Cell Biology and Human Anatomy, School of Medicine, University of California, Davis, CA (United States); Menon, Anil G. [University of Cincinnati College of Medicine, Cincinnati, OH (United States); Mathias, Richard T. [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States); Varadaraj, Kulandaiappan, E-mail: kulandaiappan.varadaraj@stonybrook.edu [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States)

    2015-07-10

    Maintenance of proper biomechanics of the eye lens is important for its structural integrity and for the process of accommodation to focus near and far objects. Several studies have shown that specialized cytoskeletal systems such as the beaded filament (BF) and spectrin-actin networks contribute to mammalian lens biomechanics; mutations or deletion in these proteins alters lens biomechanics. Aquaporin 0 (AQP0), which constitutes ∼45% of the total membrane proteins of lens fiber cells, has been shown to function as a water channel and a structural cell-to-cell adhesion (CTCA) protein. Our recent ex vivo study on AQP0 knockout (AQP0 KO) mouse lenses showed the CTCA function of AQP0 could be crucial for establishing the refractive index gradient. However, biomechanical studies on the role of AQP0 are lacking. The present investigation used wild type (WT), AQP5 KO (AQP5{sup −/−}), AQP0 KO (heterozygous KO: AQP0{sup +/−}; homozygous KO: AQP0{sup −/−}; all in C57BL/6J) and WT-FVB/N mouse lenses to learn more about the role of fiber cell AQPs in lens biomechanics. Electron microscopic images exhibited decreases in lens fiber cell compaction and increases in extracellular space due to deletion of even one allele of AQP0. Biomechanical assay revealed that loss of one or both alleles of AQP0 caused a significant reduction in the compressive load-bearing capacity of the lenses compared to WT lenses. Conversely, loss of AQP5 did not alter the lens load-bearing ability. Compressive load-bearing at the suture area of AQP0{sup +/−} lenses showed easy separation while WT lens suture remained intact. These data from KO mouse lenses in conjunction with previous studies on lens-specific BF proteins (CP49 and filensin) suggest that AQP0 and BF proteins could act co-operatively in establishing normal lens biomechanics. We hypothesize that AQP0, with its prolific expression at the fiber cell membrane, could provide anchorage for cytoskeletal structures like BFs and

  2. Medium-Term Visual Outcomes of Apodized Diffractive Multifocal Intraocular Lens with +3.00 D Addition Power

    OpenAIRE

    Guo, Xiaohong; Sun, Yi; Zhang, Bowen; Zheng, Danying

    2014-01-01

    Purpose. To evaluate 2-year visual acuities and questionnaire after bilateral implantation of SN6AD1 multifocal intraocular lens (MIOL) or SN60WF IOL. Methods. Patients randomly scheduled for bilateral implantation of SN6AD1 MIOL and SN60WF IOL with 2-year follow-up were enrolled. Uncorrected/corrected distance and near visual acuity, uncorrected intermediate visual acuity at 63 cm under high and low contrast, reading activity, the defocus curve, and a quality-of-life questionnaire were evalu...

  3. Contractual considerations in contact lens practice.

    Science.gov (United States)

    Classé, J G

    1986-03-01

    The use of forms in contact lens practice can save time, promote patient education, and reduce the opportunity for legal or economic disputes. The most commonly employed forms are those for contact lens fitting agreements, instructions for care and maintenance of lenses, prepaid service agreements, clinical investigations of investigatory lenses or solutions, and for extended wear patients. Sample forms are utilized for purposes of illustration.

  4. Evolution and the Calcite Eye Lens

    OpenAIRE

    Williams, Vernon L.

    2013-01-01

    Calcite is a uniaxial, birefringent crystal, which in its optically transparent form, has been used for animal eye lenses, the trilobite being one such animal. Because of the calcite birefringence there is a difficulty in using calcite as a lens. When the propagation direction of incoming light is not exactly on the c-axis, the mages blur. In this paper, calcite blurring is evaluated, and the non-blurring by a crystallin eye lens is compared to a calcite one.

  5. Acute lens-induced glaucomas: A review

    Directory of Open Access Journals (Sweden)

    Syed Shoeb Ahmad

    2017-02-01

    Full Text Available Lens-induced factors are important and common mechanisms causing acute elevation of intraocular pressure. While in most cases, the diagnosis and management are straight-forward, in others it is difficult and can lead to improper procedures, complications and poor visual outcomes. This review was done with the aim of studying the various types of lens-induced glaucomas, classifying them in an easy way to understand manner, their clinical features, current management and future possibilities.

  6. Complications after cardiac implantable electronic device implantations

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard

    2014-01-01

    Complications after cardiac implantable electronic device (CIED) treatment, including permanent pacemakers (PMs), cardiac resynchronization therapy devices with defibrillators (CRT-Ds) or without (CRT-Ps), and implantable cardioverter defibrillators (ICDs), are associated with increased patient...

  7. A wide-FoV athermalized infrared imaging system with a two-element lens

    Science.gov (United States)

    Feng, Bin; Shi, Zelin; Zhao, Yaohong; Liu, Haizheng; Liu, Li

    2017-12-01

    For infrared imaging systems to achieve wide field of view (FoV), wide operating temperature and low weight, this work designs a wide-FoV athermalized infrared imaging system (AIIS) with a two-element lens. Its principle, design, manufacture, measurement and performance validation are successively discussed. The two-element lens contains four surfaces, where three aspheric surfaces are introduced to reduce optical off-axis aberrations and a cubic surface is introduced to achieve athermalization. The key coding mask containing an aspheric surface and a cubic surface is manufactured by nano-metric machining of ion implanted material (NiIM). Experimental results validate that our wide-FoV wavefront coding AIIS has a full FoV of 26.10° and an operating temperature over -20 °C to +70 °C.

  8. Results of phacoemulsification of cataract complicated by lens subluxation depending on the ring setting method

    Directory of Open Access Journals (Sweden)

    N. G. Zavgorodnjaja

    2015-02-01

    Full Text Available Actuality. Cataract extraction complicated by zonular weakness remains one of the urgent problems of eye microsurgery. Aim. To increase the efficiency of cataract surgery complicated by lens subluxation through comparative analysis of frequency and structure of intra- and postoperative complications, as well as the functional results of surgical treatment of patients depending on the ring setting method. Methods and results. 91 patients (93 eyes were examined, who were operated on complicated cataract, and were divided into 2 groups depending on the method of ring setting. Conclusion. It was established that the offered method of implant capsular ring gives the opportunity to reduce the length of patients’ treatment by 2,6 day, to decrease of 28,43% for complications, and also to avoid such heavy operating complications, as a vitreous prolapse, displacement of the eye lens fragments in a vitreous body, dug up capsule bag.

  9. Air bubble and Viscoelastic agents in production of posterior capsular opacity and pigment deposition over the intraocular lens

    Directory of Open Access Journals (Sweden)

    H Attarzadeh

    2006-05-01

    Full Text Available Background: In cataract surgery, viscoelastic agents form anterior chamber, complicating to posterior capsular opacity and pigment deposition over intraocular lens after lens implantation. We compared the rate of these complications for air bubble and viscoelastic agents. Methods: Patients with senile cataract and candidate for routine cataract extraction were studied. They were randomly divided into group A (n=62 and group B (n=66. During operation and at the time of intraocular lens implantation, anterior chamber was formed by air bubble (in group A and with viscoelastic agents (in group B. All patients were followed for 3 to 6 months. Results: The rate of posterior capsular opacity and pigment deposition over the intraocular lens were significantly higher in group B (40.9% vs. 21% than group A (30.3% vs. 9.7%, respectively. Conclusion: Air bubble is a good substitution for viscoelastic agents in the formation of anterior chamber during cataract, either for decreasing complications or expensive materials. Keywords: Posterior capsular opacity, cataract extraction, viscoelastic agent, air bubble

  10. Acoustic lens for capacitive micromachined ultrasonic transducers

    Science.gov (United States)

    Chang, Chienliu; Firouzi, Kamyar; Park, Kwan Kyu; Sarioglu, Ali Fatih; Nikoozadeh, Amin; Yoon, Hyo-Seon; Vaithilingam, Srikant; Carver, Thomas; Khuri-Yakub, Butrus T.

    2014-08-01

    Capacitive micromachined ultrasonic transducers (CMUTs) have great potential to compete with traditional piezoelectric transducers in therapeutic ultrasound applications. In this paper we have designed, fabricated and developed an acoustic lens formed on the CMUT to mechanically focus ultrasound. The acoustic lens was designed based on the paraxial theory and made of silicone rubber for acoustic impedance matching and encapsulation. The CMUT was fabricated based on the local oxidation of silicon (LOCOS) and fusion-bonding. The fabricated CMUT was verified to behave like an electromechanical resonator in air and exhibited wideband response with a center frequency of 2.2 MHz in immersion. The fabrication for the acoustic lens contained two consecutive mold castings and directly formed on the surface of the CMUT. Applied with ac burst input voltages at the center frequency, the CMUT with the acoustic lens generated an output pressure of 1.89 MPa (peak-to-peak) at the focal point with an effective focal gain of 3.43 in immersion. Compared to the same CMUT without a lens, the CMUT with the acoustic lens demonstrated the ability to successfully focus ultrasound and provided a viable solution to the miniaturization of the multi-modality forward-looking endoscopes without electrical focusing.

  11. Acoustic lens for capacitive micromachined ultrasonic transducers

    International Nuclear Information System (INIS)

    Chang, Chienliu; Firouzi, Kamyar; Sarioglu, Ali Fatih; Nikoozadeh, Amin; Yoon, Hyo-Seon; Vaithilingam, Srikant; Carver, Thomas; Khuri-Yakub, Butrus T; Kyu Park, Kwan

    2014-01-01

    Capacitive micromachined ultrasonic transducers (CMUTs) have great potential to compete with traditional piezoelectric transducers in therapeutic ultrasound applications. In this paper we have designed, fabricated and developed an acoustic lens formed on the CMUT to mechanically focus ultrasound. The acoustic lens was designed based on the paraxial theory and made of silicone rubber for acoustic impedance matching and encapsulation. The CMUT was fabricated based on the local oxidation of silicon (LOCOS) and fusion-bonding. The fabricated CMUT was verified to behave like an electromechanical resonator in air and exhibited wideband response with a center frequency of 2.2 MHz in immersion. The fabrication for the acoustic lens contained two consecutive mold castings and directly formed on the surface of the CMUT. Applied with ac burst input voltages at the center frequency, the CMUT with the acoustic lens generated an output pressure of 1.89 MPa (peak-to-peak) at the focal point with an effective focal gain of 3.43 in immersion. Compared to the same CMUT without a lens, the CMUT with the acoustic lens demonstrated the ability to successfully focus ultrasound and provided a viable solution to the miniaturization of the multi-modality forward-looking endoscopes without electrical focusing. (paper)

  12. LENS: Science Scope and Development Stages

    Science.gov (United States)

    Vogelaar, R. Bruce

    2013-04-01

    The Low-Energy Neutrino Spectroscopy (LENS) experiment will resolve the solar metallicity question via measurement of the CNO neutrino flux, as well as test the predicted equivalence of solar luminosity as measured by photon versus neutrinos. The LENS detector uses charged-current interaction of neutrinos on Indium-115 (loaded in a scintillator, InLS) to reveal the complete solar neutrino spectrum. LENS's optically segmented 3D lattice geometry achieves precise time and spatial resolution and unprecedented background rejection and sensitivity for low-energy neutrino events. This first-of-a-kind lattice design is also suited for a range of other applications where high segmentation and large light collection are required (eg: sterile neutrinos with sources, double beta decay, and surface detection of reactor neutrinos). The physics scope, detector design, and logic driving the microLENS and miniLENS prototyping stages will be presented. The collaboration is actively running programs; building, operating, developing, and simulating these prototypes using the Kimballton Underground Research Facility (KURF). New members are welcome to the LENS Collaboration, and interested parties should contact R. Bruce Vogelaar.

  13. Application of fibrin glue with bandage contact lens in pterygium surgery

    Directory of Open Access Journals (Sweden)

    Wei Liu

    2014-05-01

    Full Text Available AIM: To explore the efficacy of fibrin glue with bandage contact lens for pain relief after pterygium surgery performed with limbal autograft transplantation.METHODS: A prospective clinical trial was carried out in 52 patients(72 eyesoperated for primary nasal pterygium. All patients were randomly divided into the fibrin glue with bandage contact lens group(experimental group, 28 cases, 38 eyesand suture group(control group, 24 cases, 34 eyes. Autologous limbal graft taken from the superotemporal limbus was used to cover the sclera after pterygium excision under local anesthesia with 20g/L lidocaine. In experimental group, the transplant was attached to the sclera with fibrin tissue adhesive and in control group with 10-0 Virgin silk sutures. Experimental group weared bandage contact lens after surgery while the control group did not. The degree of pain after surgery was evaluated at 1, 2, 3, 5 and 7d after surgery. Follow-up was 6mo, matching degree of graft and complication such as infection, relapse, implant healing badness and subconjunctival cyst were mainly observed and recorded.RESULTS: The pain index scores of the experimental group were significantly less than those of control group(all P=0.000. In observation period, all conjunctival autografts in both groups were successfully attached and were intact without falling off, dissolution or recurrence and there were no complications such as infection, relapse, implant healing badness and subconjunctival cyst.CONCLUSION: Fibrin glue with bandage contact lens could significantly release pain response afterpterygium excision surgery.

  14. Implantation of scleral fixated sutured posterior chamber lenses: a retrospective analysis of 119 cases.

    Science.gov (United States)

    Krause, Lothar; Bechrakis, Nikolaos E; Heimann, Heinrich; Salditt, Stefan; Foerster, Michael H

    2009-08-01

    The implantation of scleral fixated sutured posterior chamber lenses enables lens implantation in the absence of adequate lens capsule support. Anterior chamber lenses and their side effects can also be avoided, particularly in cases of unilateral aphakia and contact lens incompatibility. This study is a retrospective analysis of 119 scleral fixated sutured posterior chamber lenses implanted in 115 patients. Seventy-nine cases of damaged zonula or damaged lens capsule and 17 cases of corneal decompensation secondary to anterior chamber lenses were the main indications for the suture fixation. The mean follow-up was 23 months (6-83 months). In 50% of all cases, improved visual acuity was achieved. Twenty-four percent of patients showed unchanged visual acuity, while 26% had poorer vision postoperatively, mainly because of corneal decompensation following anterior chamber lens explantation. The main postoperative complication was transient rise of intraocular pressure, occurring in 44% of the cases. In most cases improved or comparable postoperative visual acuity was achieved. The main complication observed was postoperative glaucoma, especially in patients with pre-existing glaucoma.

  15. Sharing of secondary electrons by in-lens and out-lens detector in low-voltage scanning electron microscope equipped with immersion lens.

    Science.gov (United States)

    Kumagai, Kazuhiro; Sekiguchi, Takashi

    2009-03-01

    To understand secondary electron (SE) image formation with in-lens and out-lens detector in low-voltage scanning electron microscopy (LV-SEM), we have evaluated SE signals of an in-lens and an out-lens detector in LV-SEM. From the energy distribution spectra of SEs with various boosting voltages of the immersion lens system, we revealed that the electrostatic field of the immersion lens mainly collects electrons with energy lower than 40eV, acting as a low-pass filter. This effect is also observed as a contrast change in LV-SEM images taken by in-lens and out-lens detectors.

  16. Retropupillary iris-claw intraocular lens in ectopia lentis in Marfan syndrome

    Directory of Open Access Journals (Sweden)

    Faria MY

    2016-06-01

    Full Text Available Mun Yueh Faria,1 Nuno Ferreira,2 Eliana Neto,1 1Vitreo Retinal Department, 2Ophthalmology Department, Santa Maria Hospital, Lisbon, Portugal Objective: To report visual outcomes, complication rate, and safety of retropupillary iris-claw intraocular lens (ICIOL in ectopia lentis in Marfan syndrome (MFS. Design: Retrospective study. Methods: Six eyes of three MFS patients with ectopia lentis underwent surgery for subluxation lens and retropupillary ICIOL implantation from October 2014 to October 2015 at the Department of Ophthalmology, Santa Maria Hospital in Lisbon, Portugal. Demographics, preoperative and postoperative best-corrected visual acuity (BCVA, and intraocular pressure were evaluated. Endothelium cell count was assessed using specular microscopy; anterior chamber depth was measured using Pentacam postoperatively; and intraocular lens position was viewed by ultrasound biomicroscopy. All patients were female; mean age was 20±14.264 years (range: 7–38 years. Results: The average follow-up period was 6.66 months (range: 4–16 months. Preoperative BCVA was 0.568±0.149 logMAR units, and postoperative BCVA was 0.066±0.121 logMAR units. The mean BCVA gain was –0.502±0.221 on the logMAR scale. Postoperative average astigmatism and intraocular pressure were 1.292±0.697 mmHg (range: 0.5–2.25 mmHg and 16 mmHg (range: 12–18 mmHg, respectively. The average endothelial cell density decreased from 3,121±178 cells/mm2 before surgery to 2,835±533 cells/mm2 after surgery (measured at last follow-up visit and in the last follow-up, representing an average endothelial cell loss of 9.16%. Mean anterior chamber depth was 4.01 mm (±0.77 mm, as measured by Pentacam. No complications were found intra- or postoperatively in any of the six studied eyes. Conclusion: Retropupillary ICIOL implantation is a safe and effective procedure in the treatment of aphakia in MFS eyes, without capsular support after surgery for ectopia lens. The six eyes that

  17. Current and future concepts of the design of the intraocular lens.

    Science.gov (United States)

    Jaffe, N S

    1985-01-01

    Anterior chamber lenses are currently much less popular than posterior chamber lenses. They are mainly used in conjunction with intracapsular cataract extraction, as a secondary lens implant, and as a back up lens in case of intraoperative complications of extracapsular cataract extraction. A major disadvantage of anterior chamber lenses is improper sizing. Rigid lenses cause the greatest ocular tenderness and present serious problems with errors in sizing but they are the easiest to explant. Semiflexible and flexible lenses show a greater tendency to develop peripheral anterior synechiae. This makes explanation a very difficult procedure. Posterior chamber lenses are the most popular today. There is a trend toward all-PMMA lenses because of concern over the biocompatibility of polypropylene. The use of a laser ridge may inhibit posterior capsule opacification and facilitate YAG laser posterior capsulectomy. Ultraviolet blockers are being incorporated as a copolymer of a mechanical additive. There is a major trend towards capsular bag fixation of posterior chamber lenses as a result of complications associated with sulcus-fixated lenses. These include: disruption of the blood-aqueous barrier due to loop penetration of the ciliary body; chafing of the posterior surface of the iris leading to transillumination defects, microhyphaemas, and pigment dispersion glaucoma. It is predicted that the number of cataract extractions and the percentage of intraocular lens implantations will continue to increase due to demographic factors. Budgetary allocations for research and development will increase because of the involvement of some of the giants of medical industry. This will lead to new implant materials and new surgical techniques.

  18. Acanthamoeba keratitis and contact lens wear.

    Science.gov (United States)

    Lindsay, Richard G; Watters, Grant; Johnson, Richard; Ormonde, Susan E; Snibson, Grant R

    2007-09-01

    Acanthamoeba keratitis is a rare but serious complication of contact lens wear that may cause severe visual loss. The clinical picture is usually characterised by severe pain, sometimes disproportionate to the signs, with an early superficial keratitis that is often misdiagnosed as herpes simplex virus (HSV) keratitis. Advanced stages of the infection are usually characterised by central corneal epithelial loss and marked stromal opacification with subsequent loss of vision. In this paper, six cases of contact lens-related Acanthamoeba keratitis that occurred in Australia and New Zealand over a three-year period are described. Three of the patients were disposable soft lens wearers, two were hybrid lens wearers and one was a rigid gas permeable lens wearer. For all six cases, the risk factors for Acanthamoeba keratitis were contact lens wear with inappropriate or ineffective lens maintenance and exposure of the contact lenses to tap or other sources of water. All six patients responded well to medical therapy that involved topical use of appropriate therapeutic agents, most commonly polyhexamethylene biguanide and propamidine isethionate, although two of the patients also subsequently underwent deep lamellar keratoplasty due to residual corneal surface irregularity and stromal scarring. Despite the significant advances that have been made in the medical therapy of Acanthamoeba keratitis over the past 10 years, prevention remains the best treatment and patients who wear contact lenses must be thoroughly educated about the proper use and care of the lenses. In particular, exposure of the contact lenses to tap water or other sources of water should be avoided.

  19. Flanged Intrascleral Intraocular Lens Fixation with Double-Needle Technique.

    Science.gov (United States)

    Yamane, Shin; Sato, Shimpei; Maruyama-Inoue, Maiko; Kadonosono, Kazuaki

    2017-08-01

    To report the clinical outcomes of a new technique for transconjunctival intrascleral fixation of an intraocular lens (IOL). Prospective, noncomparative, interventional case series. One hundred eyes of 97 consecutive patients with aphakia, dislocated IOL, or subluxated crystalline lens who underwent posterior chamber sutureless implantation of an IOL were studied. Two angled incisions parallel to the limbus were made by 30-gauge thin-wall needles. Haptics of an IOL were externalized with the needles and cauterized to make a flange of the haptics. The flange of the haptics were pushed back and fixed into the scleral tunnels. Best-corrected visual acuity (VA), corneal endothelial cell density, IOL tilt, and complications were determined. The IOLs were fixed with exact centration and axial stability. The mean preoperative best-corrected VA was 0.25 logarithm of the minimum angle of resolution (logMAR) units; after surgery, it improved significantly to 0.11 logMAR, 0.09 logMAR, 0.12 logMAR, and 0.04 logMAR at 6, 12, 24, and 36 months, respectively (P IOL tilt was 3.4°±2.5°. The postoperative complications included iris capture by the IOL in 8 eyes (8%), vitreous hemorrhage in 5 eyes (5%), and cystoid macular edema in 1 eye (1%). There were no incidents of postoperative retinal detachment, endophthalmitis, or IOL dislocation. We have developed a new technique for intrascleral IOL fixation. The flanged IOL fixation technique is a simple and minimally invasive method for achieving good IOL fixation with firm haptic fixation. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  20. Properties of the cathode lens combined with a focusing magnetic/immersion-magnetic lens

    International Nuclear Information System (INIS)

    Konvalina, I.; Muellerova, I.

    2011-01-01

    The cathode lens is an electron optical element in an emission electron microscope accelerating electrons from the sample, which serves as a source for a beam of electrons. Special application consists in using the cathode lens first for retardation of an illuminating electron beam and then for acceleration of reflected as well as secondary electrons, made in the directly imaging low energy electron microscope or in its scanning version discussed here. In order to form a real image, the cathode lens has to be combined with a focusing magnetic lens or a focusing immersion-magnetic lens, as used for objective lenses of some commercial scanning electron microscopes. These two alternatives are compared with regards to their optical properties, in particular with respect to predicted aberration coefficients and the spot size, as well as the optimum angular aperture of the primary beam. The important role of the final aperture size on the image resolution is also presented.

  1. Lens exposure during brain scans using multidetector row CT scanners: methods for estimation of lens dose.

    Science.gov (United States)

    Suzuki, S; Furui, S; Ishitake, T; Abe, T; Machida, H; Takei, R; Ibukuro, K; Watanabe, A; Kidouchi, T; Nakano, Y

    2010-05-01

    Some recent studies on radiation lens injuries have indicated much lower dose thresholds than specified by the current radiation protection guidelines. The purpose of this research was to measure the lens dose during brain CT scans with multidetector row CT and to assess methods for estimating the lens dose. With 8 types of multidetector row CT scanners, both axial and helical scans were obtained for the head part of a human-shaped phantom by using normal clinical settings with the orbitomeatal line as the baseline. We measured the doses on both eyelids by using an RPLGD during whole-brain scans including the orbit with the starting point at the level of the inferior orbital rim. To assess the effect of the starting points on the lens doses, we measured the lens doses by using 2 other starting points for scanning (the orbitomeatal line and the superior orbital rim). The CTDIvols and the lens doses during whole-brain CT including the orbit were 50.9-113.3 mGy and 42.6-103.5 mGy, respectively. The ratios of lens dose to CTDIvol were 80.6%-103.4%. The lens doses decreased as the starting points were set more superiorly. The lens doses during scans from the superior orbital rim were 11.8%-20.9% of the doses during the scans from the inferior orbital rim. CTDIvol can be used to estimate the lens dose during whole-brain CT when the orbit is included in the scanning range.

  2. Individual titanium zygomatic implant

    Science.gov (United States)

    Nekhoroshev, M. V.; Ryabov, K. N.; Avdeev, E. V.

    2018-03-01

    Custom individual implants for the reconstruction of craniofacial defects have gained importance due to better qualitative characteristics over their generic counterparts – plates, which should be bent according to patient needs. The Additive Manufacturing of individual implants allows reducing cost and improving quality of implants. In this paper, the authors describe design of zygomatic implant models based on computed tomography (CT) data. The fabrication of the implants will be carried out with 3D printing by selective laser melting machine SLM 280HL.

  3. Development of Powerhouse Using Fresnel lens

    Directory of Open Access Journals (Sweden)

    Al-Dohani Nawar Saif

    2018-01-01

    Full Text Available Solar energy is an alternative source of renewable energy. Sultanate of Oman government showed initiation on utilization of solar energy for domestic and industrial applications. Fresnel lens is one of the methods to collect maximum energy by gathering heat of the sun in the concentrated form (using solar collectors. Earlier research work discloses that Fresnel lens gave better result in terms of power output and produces lower heat loss as compared to linear –parabolic solar collectors. In this work, development of a proto Fresnel lens power house was made to generate electricity. The focused heat from Fresnel lens was used to heat the molten salt in a heat exchanger to produce the steam. The generated steam was used to rotate the steam engine coupled to a generator. In the current work, a maximum power of 30 W was produced. In addition, comparative study was carried out regarding solar salts and heat exchanger materials to understand the Fresnel powerhouse performance. Overall the present study gave valuable information regarding usage of Fresnel lens for electricity generation in Oman.

  4. Non-compliance in contact lens wear.

    Science.gov (United States)

    Claydon, B E; Efron, N

    1994-10-01

    Non-compliance is emerging as a critical issue in the contact lens field. This problem has been studied at depth in general health care situations and is seen as the responsibility of both practitioner and patient (client) working in a health care partnership. The contact lens practitioner and patient present a specific case for the study of non-compliance in areas such as hygiene, solution use, appointment attendance and wearing times. From 40 to 91% of contact lens patients have been reported as non-complaint in the use of recommended care and maintenance regimens and many of these are confused or ignorant about their behaviour. In order to arrive at a general set of conclusions from the studies published to date, it is important to understand the methodology of each study, it purpose, the definition of non-compliance used and the way the results were analysed and described. This review summarizes the research into non-compliance in the contact lens field to data. A set of general conclusions is drawn and a model for compliance in the context of contact lens practice is proposed.

  5. Spherical aberration in contact lens wear.

    Science.gov (United States)

    Lindskoog Pettersson, A; Jarkö, C; Alvin, A; Unsbo, P; Brautaset, R

    2008-08-01

    The aim of the present studies was to investigate the effect on spherical aberration of different non custom-made contact lenses, both with and without aberration control. A wavefront analyser (Zywave, Bausch & Lomb) was used to measure the aberrations in each subject's right eye uncorrected and with the different contact lenses. The first study evaluated residual spherical aberration with a standard lens (Focus Dailies Disposable, Ciba Vision) and with an aberration controlled contact lens (ACCL) (Definition AC, Optical Connection Inc.). The second study evaluated the residual spherical aberrations with a monthly disposable silicone hydrogel lens with aberration reduction (PureVision, Bausch & Lomb). Uncorrected spherical aberration was positive for all pupil sizes in both studies. In the first study, residual spherical aberration was close to zero with the standard lens for all pupil sizes whereas the ACCL over-corrected spherical aberration. The results of the second study showed that the monthly disposable lens also over-corrected the aberration making it negative. The changes in aberration were statistically significant (plenses. Since the amount of aberration varies individually we suggest that aberrations should be measured with lenses on the eye if the aim is to change spherical aberration in a certain direction.

  6. A lazy way to design infrared lens

    Science.gov (United States)

    Qiu, RongSheng; Wu, JianDong; Chen, LongJiang; Yu, Kun; Pang, HaoJun; Hu, BaiZhen

    2017-08-01

    We designed a compact middle-wave infrared (MWIR) lens with a large focal length ratio (about 1.5:1), used in the 3.7 to 4.8 μm range. The lens is consisted of a compact front group and a re-imaging group. Thanks to the compact front group configuration, it is possible to install a filter wheel mechanism in such a tight space. The total track length of the lens is about 50mm, which includes a 2mm thick protective window and a cold shield of 12mm. The full field of view of the lens is about 3.6°, and F number is less than 1.6, the image circle is about 4.6mm in diameter. The design performance of the lens reaches diffraction limitation, and doesn't change a lot during a temperature range of -40°C +60°C. This essay proposed a stepwise design method of infrared optical system guided by the qualitative approach. The method fully utilize the powerful global optimization ability, with a little effort to write code snippet in optical design software, frees optical engineer from tedious calculation of the original structure.

  7. TESS Lens-Bezel Assembly Modal Testing

    Science.gov (United States)

    Dilworth, Brandon J.; Karlicek, Alexandra

    2017-01-01

    The Transiting Exoplanet Survey Satellite (TESS) program, led by the Kavli Institute for Astrophysics and Space Research at the Massachusetts Institute of Technology (MIT) will be the first-ever spaceborne all-sky transit survey. MIT Lincoln Laboratory is responsible for the cameras, including the lens assemblies, detector assemblies, lens hoods, and camera mounts. TESS is scheduled to be launched in August of 2017 with the primary goal to detect small planets with bright host starts in the solar neighborhood, so that detailed characterizations of the planets and their atmospheres can be performed. The TESS payload consists of four identical cameras and a data handling unit. Each camera consists of a lens assembly with seven optical elements and a detector assembly with four charge-coupled devices (CCDs) including their associated electronics. The optical prescription requires that several of the lenses are in close proximity to a neighboring element. A finite element model (FEM) was developed to estimate the relative deflections between each lens-bezel assembly under launch loads to predict that there are adequate clearances preventing the lenses from making contact. Modal tests using non-contact response measurements were conducted to experimentally estimate the modal parameters of the lens-bezel assembly, and used to validate the initial FEM assumptions. Key Words Non-contact measurements, modal analysis, model validation

  8. Opacificação tardia de lente intra-ocular de polimetilmetacrilato (PMMA: relato de caso Late opacification of a polymethylmethacrylate (PMMA intraocular lens: case report

    Directory of Open Access Journals (Sweden)

    Otacílio de Oliveira Maia Júnior

    2005-10-01

    Full Text Available O implante das lentes intra-oculares foi grande avanço na reabilitação visual de pacientes submetidos à cirurgia de extração da catarata. Contudo, os materiais utilizados na fabricação destas lentes, apesar de terem boa biocompatibilidade, são passíveis de alterações posteriores ao implante. No presente estudo, os autores relatam um caso raro de opacificação tardia de lente de polimetilmetacrilato, material inerte e bem tolerado intra-ocularmente, discutindo aspectos importantes no manejo desta complicação, bem como indicação de explante e substituição da lente.The use of intraocular lenses was a great advance in visual recovery after cataract surgery. Although usually with good biocompatibility, some alterations in the intraocular lens material may occur after implantation. Polymethylmethacrylate was the first intraocular lens material to be used on a large scale and assumed to be inert and well-tolerated. We present a rare case of late opacification of a polymethylmethacrylate lens, discussing important aspects of its management such as the indication for intraocular lens exchange.

  9. A case report of intraocular lens luxation with the capsular bag after vitrectomy.

    Science.gov (United States)

    Kawai, Kenji; Bando, Masayasu; Suzuki, Takahiro; Hayakawa, Kenji

    2004-04-01

    We experienced a case of intraocular lens (IOL) luxation with the capsular bag after vitrectomy. The case was a 66-year-old female in whom an IOL was implanted one year after surgery for giant tear retinal detachment using silicone oil. Four years after the implantation surgery, the patient suffered subluxation of the IOL with the capsular bag. Examinations of the luxated IOL with the capsular bag using a stereoscopic microscope confirmed the presence of silicone oil droplets between the capsule and the IOL. Adhesion of vitreous body residues was observed in the capsule. Luxation of the IOL was thought to be connected with chronic inflammation resulting from the use of silicone oil and repeated vitrectomy. In addition to examining pathological findings of luxated IOL, it would also be important in the future to identify the pathology of the capsular bag.

  10. Acanthamoeba, bacterial, and fungal contamination of contact lens storage cases.

    Science.gov (United States)

    Gray, T B; Cursons, R T; Sherwan, J F; Rose, P R

    1995-01-01

    BACKGROUND--Microbial corneal infection is the most serious complication of contact lens wear. Contact lens cases are a recognised potential source of pathogens associated with corneal ulcers. METHODS--This survey established the incidence of protozoal, bacterial, and fungal contact lens case contamination in 101 asymptomatic daily wear cosmetic contact lens wearers from a domiciliary contact lens practice. RESULTS--Eighty two (81%) contact lens cases were found to be contaminated, with 19 (19%) sterile. Of all contact lens cases, 78 (77%) grew bacteria, 24 (24%) fungi, and 20 (20%) protozoa. Acanthamoeba spp were isolated from eight (8%) contact lens cases. Fifty six (55%) contact lens cases yielded mixed bacterial contamination. This is the first contact lens case survey in which hydrogen peroxide disinfection was the major method of contact lens disinfection (75% of subjects) and no home made saline was used. All the contaminating organisms were shown to possess the enzyme catalase that breaks down hydrogen peroxide to oxygen and water. The polymicrobial nature of the biofilms found in many contact lens cases is illustrated electron micrographically. CONCLUSION--Based on data from this and previous studies, the authors conclude with recommendations for contact lens wearers: (1) regular scrubbing of contact lens case interior to disrupt biofilms; (2) exposure of contact lens case to very hot water (> or = 70 degrees C) will kill Acanthamoeba contaminants; (3) allow contact lens case to air dry between uses; (4) if hydrogen peroxide disinfection is preferred, use a two step system; (5) replace contact lens case regularly. Images PMID:7626578

  11. Characterization of lens based photoacoustic imaging system

    Directory of Open Access Journals (Sweden)

    Kalloor Joseph Francis

    2017-12-01

    Full Text Available Some of the challenges in translating photoacoustic (PA imaging to clinical applications includes limited view of the target tissue, low signal to noise ratio and the high cost of developing real-time systems. Acoustic lens based PA imaging systems, also known as PA cameras are a potential alternative to conventional imaging systems in these scenarios. The 3D focusing action of lens enables real-time C-scan imaging with a 2D transducer array. In this paper, we model the underlying physics in a PA camera in the mathematical framework of an imaging system and derive a closed form expression for the point spread function (PSF. Experimental verification follows including the details on how to design and fabricate the lens inexpensively. The system PSF is evaluated over a 3D volume that can be imaged by this PA camera. Its utility is demonstrated by imaging phantom and an ex vivo human prostate tissue sample.

  12. Freeform micromachining of an infrared Alvarez lens

    Science.gov (United States)

    Smilie, Paul J.; Dutterer, Brian S.; Lineberger, Jennifer L.; Davies, Matthew A.; Suleski, Thomas J.

    2011-02-01

    In 1967, Luis Alvarez introduced a novel concept for a focusing lens whereby two transmitting elements with cubic polynomial surfaces yield a composite lens of variable focal length with small lateral shifts. Computer simulations have demonstrated the behavior of these devices, but fabricating the refractive cubic surfaces of the types needed with adequate precision and depth modulation has proven to be challenging using standard methods, and, to the authors' knowledge, Alvarez lens elements have not been previously machined in infrared materials. Recent developments in freeform diamond machining capability have enabled the fabrication of such devices. In this paper, we discuss the fabrication of freeform refractive Alvarez elements in germanium using diamond micro-milling on a five-axis Moore Nanotech® 350FG Freeform Generator. Machining approaches are discussed, and measurements of surface figure and finish are presented. Initial experimental tests of optical performance are also discussed.

  13. 3D printed helical antenna with lens

    KAUST Repository

    Farooqui, Muhammad Fahad

    2016-12-19

    The gain of an antenna can be enhanced through the integration of a lens, however this technique has traditionally been restricted to planar antennas due to fabrication limitations of standard manufacturing processes. Here, with a unique combination of 3D and 2D inkjet printing of dielectric and metallic inks respectively, we demonstrate a Fresnel lens that has been monolithically integrated to a non-planar antenna (helix) for the first time. Antenna measurements show that the integration of a Fresnel lens enhances the gain of a 2-turn helix by around 4.6 dB giving a peak gain of about 12.9 dBi at 8.8 GHz.

  14. An "ESA-affordable" Laue-lens

    DEFF Research Database (Denmark)

    Lund, Niels

    2005-01-01

    With ESA's INTEGRAL mission gamma-ray astronomy has advanced to the point where major scientific advances must be expected from detailed studies of the many new point sources. The interest in developing focusing telescopes operating in the soft gamma-ray regime up to 1 MeV is therefore mounting r...... constraints of a specific medium size launch vehicle. The introduction of the lens mass as a primary design driver has some surprising effects for the choice of material for the crystals and new tradeoff considerations are introduced....... rapidly. Telescopes based on Laue diffraction of gamma-rays from crystals appear as one promising route, although the practical difficulties of realizing a large scale Laue lens are certainly not small. In this paper I have attempted to develop an optimized lens design considering the size and mass...

  15. The effectiveness of soft contact lens disinfection systems against Acanthamoeba on the lens surface.

    Science.gov (United States)

    Liedel, K K; Begley, C G

    1996-03-01

    This investigation compared the efficacy of three widely used contact lens disinfection systems against an ocular isolate of Acanthamoeba polyphaga. Twenty-seven worn Ciba NewVues lenses were quartered, heat sterilized and inoculated with Acanthamoeba. Lens quarters were then randomly assigned to three experimental groups, with Group A lenses exposed to cleaner and saline rinse only, Group B to disinfection only, and Group C to both cleaner and disinfection. One quarter of each lens served as a control and the other three quarters were experimental. Quantification of viable Acanthamoeba remaining on the lens was performed after each step of the disinfection process. Group A lenses showed no significant difference between the treatments, or the treatments and the control. Group B lenses demonstrated a significant difference (p = 0.0001) between the treatments and the control. In Group C (cleaning and disinfection), the control lens quarters were significantly different (p = 0.037) from the experimental group, but there was no significant difference between the treatments. All three disinfection regimens were very effective in reducing the number of viable Acanthamoeba on the contact lens surface. In the absence of proper cleaning (Group B), AOSept was the most effective of the three. These results also show the importance of thoroughly rubbing the contact lens surface to decrease the number of Acanthamoeba.

  16. Non-compliance with lens care and maintenance in diabetic contact lens wearers.

    Science.gov (United States)

    O'Donnell, Clare; Efron, Nathan

    2004-11-01

    We hypothesize that diabetic contact lens wearers may represent a special group displaying higher levels of compliance with their lens care regimens as a result of learned behaviour relating to maintenance of their diabetic condition. To test this hypothesis, a prospective, single centre, controlled, masked study was performed whereby 29 diabetic contact lens patients and 29 non-diabetic control subjects were issued with disposable hydrogel contact lenses and a multipurpose lens care regimen. All participants were given identical instruction on lens care and maintenance. Compliance levels were assessed at a 12-month aftercare appointment by demonstration and questionnaire. Twenty-four different aspects of compliance were scored, 12 by observation and 12 by questionnaire report, of which only two showed a significant difference between the diabetic and control groups. Although the combined population of contact lens wearers was generally compliant, there were examples of non-compliance in both groups. Neither the duration of diabetes nor the degree of metabolic control appeared to have a significant effect on compliance. The results suggest that eye care practitioners cannot assume that diabetic patients will be more compliant with contact lens care and maintenance than non-diabetic patients.

  17. Analytic models of plausible gravitational lens potentials

    International Nuclear Information System (INIS)

    Baltz, Edward A.; Marshall, Phil; Oguri, Masamune

    2009-01-01

    Gravitational lenses on galaxy scales are plausibly modelled as having ellipsoidal symmetry and a universal dark matter density profile, with a Sérsic profile to describe the distribution of baryonic matter. Predicting all lensing effects requires knowledge of the total lens potential: in this work we give analytic forms for that of the above hybrid model. Emphasising that complex lens potentials can be constructed from simpler components in linear combination, we provide a recipe for attaining elliptical symmetry in either projected mass or lens potential. We also provide analytic formulae for the lens potentials of Sérsic profiles for integer and half-integer index. We then present formulae describing the gravitational lensing effects due to smoothly-truncated universal density profiles in cold dark matter model. For our isolated haloes the density profile falls off as radius to the minus fifth or seventh power beyond the tidal radius, functional forms that allow all orders of lens potential derivatives to be calculated analytically, while ensuring a non-divergent total mass. We show how the observables predicted by this profile differ from that of the original infinite-mass NFW profile. Expressions for the gravitational flexion are highlighted. We show how decreasing the tidal radius allows stripped haloes to be modelled, providing a framework for a fuller investigation of dark matter substructure in galaxies and clusters. Finally we remark on the need for finite mass halo profiles when doing cosmological ray-tracing simulations, and the need for readily-calculable higher order derivatives of the lens potential when studying catastrophes in strong lenses

  18. Photonic crystal based polarization insensitive flat lens

    Science.gov (United States)

    Turduev, M.; Bor, E.; Kurt, H.

    2017-07-01

    The paper proposes a new design of an inhomogeneous artificially created photonic crystal lens structure consisting of annular dielectric rods to efficiently focus both transverse electric and transverse magnetic polarizations of light into the same focal point. The locations of each individual cell that contains the annular dielectric rods are determined according to a nonlinear distribution function. The inner and outer radii of the annular photonic dielectric rods are optimized with respect to the polarization insensitive frequency response of the transmission spectrum of the lens structure. The physical background of the polarization insensitive focusing mechanism is investigated in both spatial and frequency domains. Moreover, polarization independent wavefront transformation/focusing has been explored in detail by investigating the dispersion relation of the structure. Corresponding phase index distribution of the lens is attained for polarization insensitive normalized frequency range of a/λ  =  0.280 and a/λ  =  0.300, where a denotes the lattice constant of the designed structure and λ denotes the wavelength of the incident light. We show the wave transformation performance and focal point movement dynamics for both polarizations of the lens structure by specially adjusting the length of the structure. The 3D finite-difference time domain numerical analysis is also performed to verifiy that the proposed design is able to focus the wave regardless of polarization into approximately the same focal point (difference between focal distances of both polarizations stays below 0.25λ) with an operating bandwidth of 4.30% between 1476 nm and 1541 nm at telecom wavelengths. The main superiorities of the proposed lens structure are being all dielectric and compact, and having flat front and back surfaces, rendering the proposed lens design more practical in the photonic integration process in various applications such as optical switch

  19. Effect of infrared radiation on the lens

    Directory of Open Access Journals (Sweden)

    Aly Eman

    2011-01-01

    Full Text Available Background: Infrared (IR radiation is becoming more popular in industrial manufacturing processes and in many instruments used for diagnostic and therapeutic application to the human eye. Aim : The present study was designed to investigate the effect of IR radiation on rabbit′s crystalline lens and lens membrane. Materials and Methods: Fifteen New Zealand rabbits were used in the present work. The rabbits were classified into three groups; one of them served as control. The other two groups were exposed to IR radiation for 5 or 10 minutes. Animals from these two irradiated groups were subdivided into two subgroups; one of them was decapitated directly after IR exposure, while the other subgroup was decapitated 1 hour post exposure. IR was delivered from a General Electric Lamp model 250R 50/10, placed 20 cm from the rabbit and aimed at each eye. The activity of Na + -K + ATPase was measured in the lens membrane. Soluble lens proteins were extracted and the following measurements were carried out: estimation of total soluble protein, sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE and Fourier transform infrared (FTIR spectroscopy. For comparison between multiple groups, analysis of variance was used with significance level set at P < 0.001. Results: The results indicated a change in the molecular weight of different lens crystalline accompanied with changes in protein backbone structure. These changes increased for the groups exposed to IR for 10 minutes. Moreover, the activity of Na + -K + ATPase significantly decreased for all groups. Conclusions: The protein of eye lens is very sensitive to IR radiation which is hazardous and may lead to cataract.

  20. Combined cataract surgery and aniridia ring implantation in oculocutaneous albinism.

    Science.gov (United States)

    Farahi, Azadeh; Hashemi, Hassan; Mehravaran, Shiva

    2015-11-01

    To present results of cataract surgery combined with aniridia ring implantation in patients with oculocutaneous albinism (OCA) in terms of vision, refraction, eye movements, and subjective photophobia and glare. Anterior segment services of Noor Eye Hospital, Tehran, Iran. Consecutive clinical case series study. Enrolled patients underwent phacoemulsification and posterior chamber intraocular lens (PC IOL) implantation and had 2 Morcher aniridia rings (types 50 F or 50 E) inserted intracapsularly. Preoperative and postoperative examinations included tests for visual acuity, manifest refraction, measurement of ocular alignment, and electronystagmography. After surgery, patients also completed a questionnaire to subjectively assess glare reduction. Twelve eyes of 6 OCA patients were included. Minimum follow-up was 6 months. None of the patients had any intraoperative or postoperative complications. In addition to improved uncorrected and corrected distance visual acuity and significant reduction of refractive error, all patients had a marked reduction of glare and photophobia after surgery. Iris ring implantation during cataract surgery was an effective procedure for increasing vision and reducing glare disability in patients with OCA. In light of the results and patients' expressed satisfaction, a study should be performed to assess the outcomes of refractive lens exchange along with implantation of a PC IOL and prosthetic iris device in OCA patients seeking refractive correction. Copyright © 2015. Published by Elsevier Inc.

  1. The corneal stroma during contact lens wear.

    Science.gov (United States)

    Jalbert, Isabelle; Stapleton, Fiona

    2005-03-01

    Recent technological advances have lead to novel descriptions of the microanatomy of the corneal stroma. In the first section of this review, these findings and the role they play in the maintenance of vital properties such as corneal transparency, mechanical strength, homeostasis, wound-healing response and metabolism are described. In the second part, contact lens induced stromal alterations such as acidosis, oedema, striae, thinning and opacities are reviewed as well as the more recently described phenomenon of microdot deposits and keratocyte loss with an emphasis on how lens wearing stromal effects can be minimised.

  2. Sterilization potential of contact lens solutions

    Directory of Open Access Journals (Sweden)

    Dada Vijay

    1988-01-01

    Full Text Available In a dynamic field of Contact Lens Solutions maintenance of high standards of anti-microbial activity is a must Resterilization Activity Time′ is a universally accepted yardstick for such an evaluation. In this study eight brands of indigenous popular solutions alongwith two FDA approved solutions were tested for their sterilization efficacy: Standardized suspensions of Pseudomonas aeruginosa, Staphylococcus aureus, Candida albicans and Aspergillus fumigatus were used for the purpose. It was observed that the contact lens solutions available ir, the domestic market were not upto the mark Suggestions for improvement have also been made.

  3. Rotman lens for mm-wavelengths

    Science.gov (United States)

    Hall, Leonard T.; Hansen, Hedley J.; Abbott, Derek

    2002-11-01

    The 77 GHz band has been reserved for intelligent cruise control in luxury cars and some public transport services in America and the United Kingdom. The Rotman lens offers a cheap and compact means to extend the single beam systems generally used, to fully functional beam staring arrangements. Rotman lenses have been built for microwave frequencies with limited success. The flexibility of microstrip transmission lines and the advent of fast accurate simulation packages allow practical Rotman lenses to be designed at mm-wavelengths. This paper discusses the limitations of the conventional design approach and predicts the performance of a new Rotman lens designed at 77 GHz.

  4. Pulse transformer for the AA lithium lens

    CERN Document Server

    CERN PhotoLab

    1980-01-01

    The antiprotons emanating from the target were initially focused by a magnetic horn. Later on, a Li-lens was used during operation for the SPS collider, until 1992. A Li-rod (130 mm long, 34 mm in diameter) constituted the secondary of a 1:23 pulse-transformer. The half-sine pulse rose to 1000 kA in 900 microsec. The angular acceptance was 95 mrad. In operation after 1992, for LEAR only, a more modest Li-lens was used (155 mm long, diameter 20 mm, 480 kA, risetime 240 microsec, angular acceptance 75 mrad).

  5. Immunochemical analyses of soluble lens proteins in some marine fishes

    Digital Repository Service at National Institute of Oceanography (India)

    Menezes, M.R.

    Soluble eye lens proteins of 10 fishes, belonging to the families Clupeidae, Hemirhamphidae, Lactaridae, Scombridae, Stromatidae, Psettodidae, Bothidae and Soleidae were studied by immunoelectrophoresis using the lens antiserum of Sardinella...

  6. Lens autofluorescence is not increased at high altitude

    DEFF Research Database (Denmark)

    Kessel, Line; Kofoed, Peter Kristian; Zubieta-Calleja, Gustavo

    2010-01-01

    PURPOSE: To study the relation between ambient environmental ultraviolet radiation exposure and lens fluorescence. METHODS: Non-invasive lens fluorometry measurements were compared in healthy Bolivian and Danish subjects. Background ultraviolet radiation was 4.5 times higher in Bolivia than in De...... living at sea level at 55 degrees northern latitude. These results suggest that lens ageing, as assessed by lens autofluorometry, is independent of exposure to ultraviolet radiation....

  7. Breast Implants: Saline vs. Silicone

    Science.gov (United States)

    ... differ in material and consistency, however. Saline breast implants Saline implants are filled with sterile salt water. ... of any age for breast reconstruction. Silicone breast implants Silicone implants are pre-filled with silicone gel — ...

  8. [Biomaterials in cochlear implants].

    Science.gov (United States)

    Stöver, T; Lenarz, T

    2009-05-01

    Cochlear implants (CI) represent the "gold standard" for the treatment of congenitally deaf children and postlingually deafened adults. Thus, cochlear implantation is a success story of new bionic prosthesis development. Owing to routine application of cochlear implants in adults but also in very young children (below the age of one), high demands are placed on the implants. This is especially true for biocompatibility aspects of surface materials of implant parts which are in contact with the human body. In addition, there are various mechanical requirements which certain components of the implants must fulfil, such as flexibility of the electrode array and mechanical resistance of the implant housing. Due to the close contact of the implant to the middle ear mucosa and because the electrode array is positioned in the perilymphatic space via cochleostomy, there is a potential risk of bacterial transferral along the electrode array into the cochlea. Various requirements that have to be fulfilled by cochlear implants, such as biocompatibility, electrode micromechanics, and although a very high level of technical standards has been carried out there is still demand for the improvement of implants as well as of the materials used for manufacturing, ultimately leading to increased implant performance. General considerations of material aspects related to cochlear implants as well as potential future perspectives of implant development will be discussed.

  9. 21 CFR 886.1420 - Ophthalmic lens gauge.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic lens gauge. 886.1420 Section 886.1420...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1420 Ophthalmic lens gauge. (a) Identification. An ophthalmic lens gauge is a calibrated device intended to manually measure the curvature of a...

  10. In vivo study of lens regeneration in Rana cyanophlyctis under ...

    African Journals Online (AJOL)

    SAM

    2014-03-12

    Mar 12, 2014 ... enhanced the percentage lens regeneration not only in young tadpoles but also in froglets. Lens regeneration ability ... Influence of vitamin A and ascorbic acid on lens regeneration in young, mature tadpoles and froglets of the frog Rana cyanophlyctis. Group .... ingested by macrophages. Dorsal iris cells ...

  11. 21 CFR 800.10 - Contact lens solutions; sterility.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Contact lens solutions; sterility. 800.10 Section...) MEDICAL DEVICES GENERAL Requirements for Specific Medical Devices § 800.10 Contact lens solutions... ophthalmic use, including contact lens solutions, should be sterile. It is further evident that such...

  12. Comparison of the biometric measurements obtained using noncontact optical biometers LenStar LS 900 and IOL Master V.5.

    Science.gov (United States)

    Kołodziejczyk, Wojciech; Gałecki, Tomasz; Łazicka-Gałecka, Monika; Szaflik, Jerzy

    2011-01-01

    Evaluation of the measurement accuracy using a new optical biometer LenStar LS 900 (Haag Strait) and comparison according to the IOL Master V.5 (Zeiss) device. In a prospective clinical study biometric measurements along with artificial lens power calculation using the LenStar LS 900 device were performed. A total number of 106 patients qualified for a cataract extraction procedure were included in the study. Measurements along with lens power calculation were repeated using the IOL Master V.5. device. Results were elaborated using Pearson's correlation and Bland-Altman plot. Measurements were performed in 204 eyes of 106 patients. Mean values and ranges of biometry results were as follows: 23.46 +/- 2.81 mm [20.79-29.80] for IOL Master, and 23.47 +/- 2.83 mm [20.79-29.86] for LenStar LS 900. In keratometry for flat meridian (K1) the following data was obtained: mean 43.24 +/- 3.22 D [range 38.27-47.94] for IOL Master and 42.44 +/- 3.15 D [38.27-47.94] for LenStar LS 900. For steep meridian (K2) the data obtained were 44.14 +/- 3.40 D; [39.29-49.13] and 43.27 +/- 3.34 D [38.61-48.4] respectively. The obtained calculation results for each eye were as follows: mean 21.23 +/- 8.07, [range 3.25-28.99] for Hagis formula, 21.14 +/- 6.90; [4.83-27.6] for SRK II, 21.04 +/- 7.78; [3.05-28.05] for SRK/T, 21.09 +/- 8.13; [2.43-28.61] for Holladay using IOL Master and 21.41 +/- 8.23; [2.99-29.15] for Haigis; 21.24 +/- 7.00; [4.6-27.71] for SRK II, 21.13 +/- 7.90; [2.76-28.18] for SRK/T; 21.09 +/- 8.13; [2.16-28.76] for Holladay using LenStar LS 900. The LenStar LS 900 device enables to perform accurate and repetitive biometric measurements and implant power calculations. Implant calculation results obtained using the LenStar LS 900 device are comparable to those achieved using the IOL Master V.5 device, which has been commonly accepted as standard for over a decade. The use of both devices is limited by significant lens opacification and posterior capsule calcification. In

  13. Multifocal Toric Intraocular Lens for Traumatic Cataract in a Child

    Directory of Open Access Journals (Sweden)

    Yanfeng Zeng

    2016-10-01

    Full Text Available A child suffering from traumatic cataract and corneal astigmatism of 2.14 D had a phacoemulsification operation and implantation of a ReSTOR Toric intraocular lens (IOL to correct the astigmatism. The primary outcome measurements were the uncorrected distance visual acuity (UDVA, uncorrected near vision at 40 cm, intraocular pressure, spherical equivalent refraction, residual astigmatism, corneal astigmatism, presence of unusual optical phenomena, and use of spectacles. At 7 months postoperatively, UDVA was maintained between 16/20 and 24/20, near vision was between J1 and J3, residual spherical refraction was 0–0.37 D, and residual refractive cylinder was between 0 and 0.67 D. A multifocal toric IOL can provide the possibility of satisfactory vision for both distant and near conditions without the use of spectacles to meet children’s needs when studying and doing sports. Additionally, binocular vision can be reconstructed. This intervention, therefore, seems to be a satisfactory alternative.

  14. Non-lens-based surgical techniques for presbyopia correction.

    Science.gov (United States)

    Bilbao-Calabuig, R; Llovet-Osuna, F

    2017-09-01

    Presbyopia is the most prevalent refractive error. With a progressive aging population, its surgical correction is an important challenge for the ophthalmology community, as well as the millions of patients who suffer from it, and who are increasingly demanding alternatives to its correction with glasses or contact lenses. A review is presented with a synthesised discussion on the pathophysiological theories of presbyopia and an updated and analytical description of the non-lens involvement surgical techniques used to treat presbyopia. Corneal procedures include various types of corneal implants and photo-ablative techniques that generate a multifocal cornea, or monovision. Scleral procedures exert a traction on supralenticular sclera that supposedly would improve the amplitude of accommodation. None of the techniques are able to completely eliminate the need for near -vision glasses, but many of them manage to improve the refractive status of the patients. More studies with rigorous and standardised methods and longer follow-up are needed to evaluate the changes in the near vision of the patients, in order to corroborate the real and practical usefulness of many of these techniques. Copyright © 2017 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Motorized injector-assisted intrascleral intraocular lens fixation.

    Science.gov (United States)

    Hung, Jia-Horung; Wang, Shih-Hao; Teng, Yu-Ti; Hsu, Sheng-Min

    2017-03-01

    For eyes with deficient capsular support, intraocular lens (IOL) implantation has long been a technical challenge. Recently, intrascleral fixation of the haptics of a three-piece posterior chamber IOL has become a popular option. In this procedure, externalization of the leading haptic during IOL injection is a stressful step. We present a modified technique to improve the ease and safety of this step. Our modified technique involves IOL injection with a motorized injector with several important modifications described here. With these modifications, a surgeon can easily maintain the correct orientation of the IOL in a well-controlled manner during IOL injection. The records of 13 patients who underwent this technique were retrospectively evaluated. Corrected-distance visual acuity improved significantly after surgery (pIOL decentration, or vitreous hemorrhage was noted during the follow-up period. In conclusion, the motorized injector-assisted intrascleral IOL fixation technique is a safe and effective alternative to the conventional procedure. This technique makes the process of leading haptic externalization easier and more controllable. Copyright © 2017. Published by Elsevier Taiwan.

  16. Motorized injector-assisted intrascleral intraocular lens fixation

    Directory of Open Access Journals (Sweden)

    Jia-Horung Hung

    2017-03-01

    Full Text Available For eyes with deficient capsular support, intraocular lens (IOL implantation has long been a technical challenge. Recently, intrascleral fixation of the haptics of a three-piece posterior chamber IOL has become a popular option. In this procedure, externalization of the leading haptic during IOL injection is a stressful step. We present a modified technique to improve the ease and safety of this step. Our modified technique involves IOL injection with a motorized injector with several important modifications described here. With these modifications, a surgeon can easily maintain the correct orientation of the IOL in a well-controlled manner during IOL injection. The records of 13 patients who underwent this technique were retrospectively evaluated. Corrected-distance visual acuity improved significantly after surgery (p<0.05. No postoperative retinal detachment, endophthalmitis, IOL decentration, or vitreous hemorrhage was noted during the follow-up period. In conclusion, the motorized injector-assisted intrascleral IOL fixation technique is a safe and effective alternative to the conventional procedure. This technique makes the process of leading haptic externalization easier and more controllable.

  17. Intermediate results of sutureless intrascleral posterior chamber intraocular lens fixation.

    Science.gov (United States)

    Scharioth, Gabor B; Prasad, Som; Georgalas, Ilias; Tataru, Calin; Pavlidis, Mitrofanis

    2010-02-01

    To report the intermediate multicenter results of a technique of sutureless intrascleral fixation of a standard 3-piece posterior chamber intraocular lens (PC IOL) in the ciliary sulcus. Four European ophthalmology centers. A technique for sutureless intrascleral fixation of the haptics of a standard 3-piece PC IOL was retrospectively evaluated. The technique uses standardized maneuvers to fixate the PC IOL without need for special haptic architecture or preparation or haptic suturing. All patients having IOL implantation by the technique were evaluated for preoperative status (visual acuity, refractive error, preexisting ocular conditions, optical biometry), postoperative status, complications, and need for further surgery. The study evaluated 63 consecutive patients from 4 institutions (4 surgeons). The median follow-up was 7 months. Two dislocated PC IOLs (3.6%) were decentered; the other 61 IOLs (96.8%) were stable and well centered. There were no cases of recurrent dislocation, endophthalmitis, retinal detachment, or glaucoma. Fixation of PC IOL haptics in a limbus-parallel scleral tunnel provided exact centration and axial stability of the IOL and prevented distortion and subluxation in most cases. Copyright 2010 ASCRS and ESCRS. All rights reserved.

  18. Solar powered desalination system using Fresnel lens

    Science.gov (United States)

    Sales, M. T. B. F.

    2016-11-01

    The Philippines is surrounded by coastal areas and these areas can be a potential source for potable water. This study aims to design and construct a solar powered desalination system using Fresnel lens. The experimental study was conducted using polluted salt water for the sample and desalination was carried out using the designed system. The desalination system was composed of the solar concentrator, solar still and the condenser system. The Fresnel lens was made of acrylic plastic and was an effective solar concentrator. Solar stills made of dark colored glass bottles were effective in absorbing the solar energy. The condenser system made of polybutylene and polystyrene were effective in condensing the vapor at ambient temperature. The shortest time of vaporization of the salt water was at 293 sec and the optimum angle of position of the lens was 36.42°. The amount of condensate collected was directly proportional to the amount of salt water in the solar still. The highest mean efficiency of the designed set-up was 34.82%. The water produced by the solar powered desalination system using Fresnel lens passed the standards set by WHO (World Health Organization) for drinking water.

  19. Electronic states in a quantum lens

    International Nuclear Information System (INIS)

    Rodriguez, Arezky H.; Trallero-Giner, C.; Ulloa, S. E.; Marin-Antuna, J.

    2001-01-01

    We present a model to find analytically the electronic states in self-assembled quantum dots with a truncated spherical cap (''lens'') geometry. A conformal analytical image is designed to map the quantum dot boundary into a dot with semispherical shape. The Hamiltonian for a carrier confined in the quantum lens is correspondingly mapped into an equivalent operator and its eigenvalues and eigenfunctions for the corresponding Dirichlet problem are analyzed. A modified Rayleigh-Schro''dinger perturbation theory is presented to obtain analytical expressions for the energy levels and wave functions as a function of the spherical cap height b and radius a of the circular cross section. Calculations for a hard wall confinement potential are presented, and the effect of decreasing symmetry on the energy values and eigenfunctions of the lens-shape quantum dot is studied. As the degeneracies of a semicircular geometry are broken for b≠a, our perturbation approach allows tracking of the split states. Energy states and electronic wave functions with m=0 present the most pronounced influence on the reduction of the lens height. The method and expressions presented here can be straightforwardly extended to deal with more general Hamiltonians, including strains and valence-band coupling effects in Group III--V and Group II--VI self-assembled quantum dots

  20. READING SCRIPTURE THROUGH A MYSTICAL LENS

    African Journals Online (AJOL)

    Reading scripture through a mystical lens. 144 the illuminatory function of scripture which confirms and explains experience, rather than in its philological or scientific status. Elisabeth often juxtaposes several texts when quoting from memory and the biblical foundation of her writings is clearly evident in certain cases which ...

  1. Corneal ring infiltration in contact lens wearers

    Directory of Open Access Journals (Sweden)

    Seyed Ali Tabatabaei

    2017-01-01

    Full Text Available To report a case of atypical sterile ring infiltrates during wearing soft silicone hydrogel contact lens due to poor lens care. A 29-year-old woman presented with complaints of pain, redness, and morning discharge. She was wearing soft silicone hydrogel contact lens previously; her current symptoms began 1 week before presentation. On examination, best-corrected visual acuity was 20/40 in that eye. Slit-lamp examination revealed dense, ring-shaped infiltrate involving both the superficial and deep stromal layers with lucid interval to the limbus, edema of the epithelium, epithelial defect, and vascularization of the superior limbus. Cornea-specific in vivo laser confocal microscopy (Heidelberg Retina Tomograph 2 Rostock Cornea Module, HRT 2-RCM, Heidelberg Engineering GmbH, Dossenheim, Germany revealed Langerhans cells and no sign of Acanthamoeba or fungal features, using lid scraping and anti-inflammatory drops; her vision completely recovered. We reported an atypical case of a sterile corneal ring infiltrate associated with soft contact lens wearing; smear, culture, and confocal microscopy confirmed a sterile inflammatory reaction.

  2. Implantable cardioverter-defibrillator

    Science.gov (United States)

    ... medlineplus.gov/ency/article/007370.htm Implantable cardioverter-defibrillator To use the sharing features on this page, please enable JavaScript. An implantable cardioverter-defibrillator (ICD) is a device that detects any life- ...

  3. Implantable cardioverter defibrillator - discharge

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000108.htm Implantable cardioverter defibrillator - discharge To use the sharing features on this page, please enable JavaScript. An implantable cardioverter-defibrillator (ICD) is a device that detects a life- ...

  4. About Implantable Contraception

    Science.gov (United States)

    ... a tube was inserted, and get a new contraceptive implant on schedule or switch to another method ... STDs. Possible Side Effects Young women who get contraceptive implants might notice such side effects as: irregular ...

  5. Urinary incontinence - collagen implants

    Science.gov (United States)

    ... gov/ency/article/007373.htm Urinary incontinence - injectable implant To use the sharing features on this page, please enable JavaScript. Injectable implants are injections of material into the urethra to ...

  6. Properties of the cathode lens combined with a focusing magnetic/immersion-magnetic lens

    Czech Academy of Sciences Publication Activity Database

    Konvalina, Ivo; Müllerová, Ilona

    2011-01-01

    Roč. 645, č. 1 (2011), s. 55-59 ISSN 0168-9002 R&D Projects: GA ČR GAP102/10/1410; GA AV ČR IAA100650902; GA MŠk ED0017/01/01 Institutional research plan: CEZ:AV0Z20650511 Keywords : cathode lens * compound objective lens * aberration coefficients * spot size * field calculations Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.207, year: 2011

  7. Conduta cirúrgica na subluxação do cristalino Surgical approach to the subluxated lens

    Directory of Open Access Journals (Sweden)

    Nórton Souto Severo

    2004-02-01

    Full Text Available OBJETIVO: Apresentar 10 casos de subluxação de cristalino, secundários a trauma ou a síndrome de Marfan, discutindo o tratamento e os resultados obtidos. MÉTODOS: Foram estudados 10 olhos de 9 pacientes, 6 casos secundários a trauma contuso e 4 casos a síndrome de Marfan. A idade média foi de 48,9 ± 18,2 anos, com tempo de seguimento de 34,6 ± 11,6 meses (12 a 62 meses. Os pacientes foram submetidos à facectomia intracapsular (1 caso, extracapsular com capsulorrexe (1 caso, facoemulsificação sem LIO (1 caso, e facoemulsificação com implante de LIO (7 casos. Anéis expansores capsulares foram utilizados em 7 olhos. RESULTADOS: Houve melhora da acuidade visual em todos os casos durante o seguimento, exceto em um, em que houve descolamento de retina, 20 dias após o procedimento. CONCLUSÃO: A facectomia com implante de LIO em pacientes com cristalino subluxado é procedimento viável, principalmente com a facoemulsificação e o uso do anel expansor capsular, podendo melhorar bastante a acuidade visual e a qualidade de vida desses pacientes.PURPOSE: To evaluate 10 cases of subluxated lens due to trauma or Marfan syndrome, focussing on their treatment and the results. METHODS: Ten eyes of 9 patients were operated on due to lens subluxation. Six eyes were due to trauma and 4 eyes to Marfan syndrome. The mean age was 48.9 ± 18.2 years, and the follow-up period of 34.6 ± 11.6 months. Patients were submitted to intracapsular lens extraction (1 eye, extracapsular lens extraction (1 eye, phacoemulsification without IOL (1 eye, and phacoemulsification with IOL (7 eyes. Endocapsular rings were used in 7 eyes. RESULTS: Best-corrected visual acuity improved in all patients, except for one, who had a regmatogeneous retinal detachment, 20 days after surgery. CONCLUSION: Lens extraction with IOL implantation in subluxated lens patients has a good prognosis, especially with pha-coemulsification and endocapsular rings. With this approach, we were

  8. Moessbauer spectroscopy of implanted sources

    International Nuclear Information System (INIS)

    Niesen, L.

    1983-01-01

    A review is given of the field of Moessbauer spectroscopy of ion-implanted sources. After an introduction to the various aspects of the ion-implantation method, the following topics are treated: final site selection of implanted impurities; trapping of defects at implanted ions; on-line implantation; implantation in metals, semiconductors and insulators. (Auth.)

  9. Implantable electronic medical devices

    CERN Document Server

    Fitzpatrick, Dennis

    2014-01-01

    Implantable Electronic Medical Devices provides a thorough review of the application of implantable devices, illustrating the techniques currently being used together with overviews of the latest commercially available medical devices. This book provides an overview of the design of medical devices and is a reference on existing medical devices. The book groups devices with similar functionality into distinct chapters, looking at the latest design ideas and techniques in each area, including retinal implants, glucose biosensors, cochlear implants, pacemakers, electrical stimulation t

  10. COCHLEAR IMPLANTATION: MY EXPERIENCE

    OpenAIRE

    Shankar

    2015-01-01

    Cochlear implant is a small, surgically implanted complex electronic device that can help to provide a sense of sound to a person with severe to profound sensorineural hearing loss. This type of hearing loss, typically involves damage to hair cells in the cochlea, as a result sound cannot reach the auditory nerve which usually receives information from hair cells. A cochlear implant skips the damaged hair cells and to stimulate the auditory nerve directly. An implant does not rest...

  11. Intrinsic lens potential of neural retina inhibited by Notch signaling as the cause of lens transdifferentiation.

    Science.gov (United States)

    Iida, Hideaki; Ishii, Yasuo; Kondoh, Hisato

    2017-01-15

    Embryonic neural retinas of avians produce lenses under spreading culture conditions. This phenomenon has been regarded as a paradigm of transdifferentiation due to the overt change in cell type. Here we elucidated the underlying mechanisms. Retina-to-lens transdifferentiation occurs in spreading cultures, suggesting that it is triggered by altered cell-cell interactions. Thus, we tested the involvement of Notch signaling based on its role in retinal neurogenesis. Starting from E8 retina, a small number of crystallin-expressing lens cells began to develop after 20 days in control spreading cultures. By contrast, addition of Notch signal inhibitors to cultures after day 2 strongly promoted lens development beginning at day 11, and a 10-fold increase in δ-crystallin expression level. After Notch signal inhibition, transcription factor genes that regulate the early stage of eye development, Prox1 and Pitx3, were sequentially activated. These observations indicate that the lens differentiation potential is intrinsic to the neural retina, and this potential is repressed by Notch signaling during normal embryogenesis. Therefore, Notch suppression leads to lens transdifferentiation by disinhibiting the neural retina-intrinsic program of lens development. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Synthesis and phototoxicity of isomeric 7,9-diglutathione pyrrole adducts: Formation of reactive oxygen species and induction of lipid peroxidation.

    Science.gov (United States)

    Ma, Liang; Zhao, Hengqiang; Xia, Qingsu; Cai, Lining; Fu, Peter P

    2015-09-01

    Pyrrolizidine alkaloids (PAs) are hepatotoxic, genotoxic, and carcinogenic in experimental animals. Because of their widespread distribution in the world, PA-containing plants are probably the most common poisonous plants affecting livestock, wildlife, and humans. Upon metabolism, PAs generate reactive dehydro-PAs and other pyrrolic metabolites that lead to toxicity. Dehydro-PAs are known to react with glutathione (GSH) to form 7-GSH-(+/-)-6,7-dihydro-7-hydroxy-1-hydroxymethyl-5H-pyrrolizine (7-GS-DHP) in vivo and in vitro and 7,9-diGS-DHP in vitro. To date, the phototoxicity of GS-DHP adducts has not been well studied. In this study, we synthesized 7-GS-DHP, a tentatively assigned 9-GS-DHP, and two enantiomeric 7,9-diGS-DHP adducts by reaction of dehydromonocrotaline with GSH. The two 7,9-diGS-DHPs were separated by high performance liquid chromatography (HPLC) and their structures were characterized by 1 H nuclear magnetic resonance (NMR) and 1 H -1 H correlation spectroscopy (COSY) NMR spectral analysis. Photoirradiation of 7-GS-DHP, 9-GS-DHP, and the two 7,9-diGS-DHPs as well as dehydromonocrotaline, dehydroheliotrine, and the 7-R enantiomer of DHP (DHR), by UVA light at 0 J/cm 2 , 14 J/cm 2 , and 35 J/cm 2 in the presence of a lipid, methyl linoleate, all resulted in lipid peroxidation in a light dose-responsive manner. The levels of lipid peroxidation induced by the two isomeric 7,9-diGS-DHPs were significantly higher than that by 7-GS-DHP and 9-GS-DHP. When 7,9-diGS-DHP was irradiated in the presence of sodium azide (NaN 3 ), the level of lipid peroxidation decreased; lipid peroxidation was enhanced when methanol was replaced by deuterated methanol. These results suggest that singlet oxygen is a product induced by the irradiation of 7,9-diGS-DHP. When irradiated in the presence of superoxide dismutase (SOD), the level of lipid peroxidation decreased, indicating that lipid peroxidation is also mediated by superoxide. These results indicate that lipid

  13. Enhanced cellular uptake and phototoxicity of Verteporfin-conjugated gold nanoparticles as theranostic nanocarriers for targeted photodynamic therapy and imaging of cancers

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Linlin [Tianjin Key Laboratory for Photoelectric Materials and Devices, School of Materials Science & Engineering, Tianjin University of Technology, Tianjin 300384 (China); Graduate School of Energy Science and Technology, Chungnam National University, Daejeon 305-764 (Korea, Republic of); Kim, Tae-Hyun; Kim, Hae-Won [Department of Nanobiomedical Science, Dankook University Graduate School, Cheonan 330-714 (Korea, Republic of); Institute of Tissue Regeneration Engineering (ITREN) & College of Dentistry, Dankook University, Cheonan 330-714 (Korea, Republic of); Ahn, Jin-Chul [Department of Biomedical Science, College of Medicine, Dankook University, Cheonan, 330-714 (Korea, Republic of); Kim, So Yeon, E-mail: kimsy@cnu.ac.kr [Graduate School of Energy Science and Technology, Chungnam National University, Daejeon 305-764 (Korea, Republic of); Department of Chemical Engineering Education, College of Education, Chungnam National University, Daejeon 305-764 (Korea, Republic of)

    2016-10-01

    Activatable theranostics with the capacity to respond to a given stimulus have recently been intensively explored to develop more specific, individualized therapies for various diseases, and to combine diagnostic and therapeutic capabilities into a single agent. In this work, we designed tumor-targeting ligand-conjugated block copolymer-gold nanoparticle (AuNP) conjugates as multifunctional nanocarriers of the hydrophobic photosensitizer (PS), verteporfin (Verte), for simultaneous photodynamic therapy and imaging of cancers. Folic acid (FA)-conjugated block copolymers composed of polyethylene glycol (PEG) and poly-β-benzyl-L-aspartate (PBLA) were attached to citrate-stabilized AuNPs through a bidentate dihydrolipoic acid (DHLA) linker. The resulting AuNP conjugates (FA-PEG-P(Asp-Hyd)-DHLA-AuNPs) were significantly more stable than unmodified AuNPs, and their optical properties were not affected by pH. The hydrophobic PS, Verte, was covalently incorporated onto the surfaces of the AuNP conjugates through a pH-sensitive linkage, which increased the water solubility of Verte from < 1 μg/ml to > 2000 μg/ml. The size of FA-PEG-P(Asp-Hyd)-DHLA-AuNPs-Verte as determined by light-scattering measurements was about 110.3 nm, and FE-SEM and FE-TEM images showed that these nanoparticles were spherical and showed adequate dispersivity after modification. In particular, an in vitro cell study revealed high intracellular uptake of FA-PEG-P(Asp-Hyd)-DHLA-AuNPs-Verte (about 98.62%) and marked phototoxicity after laser irradiation compared with free Verte. These results suggest that FA-PEG-P(Asp-Hyd)-DHLA-AuNPs-Verte has great potential as an effective nanocarrier for dual imaging and photodynamic therapy. - Highlights: • We designed theranostic nanocarriers for photodynamic therapy and imaging of cancers. • AuNP conjugates had a spherical shape and a narrow size distribution with a mean diameter of 110.3 nm. • Cellular uptake of free Verte was 18.86%, whereas that of Au

  14. Synthesis and phototoxicity of isomeric 7,9-diglutathione pyrrole adducts: Formation of reactive oxygen species and induction of lipid peroxidation

    Directory of Open Access Journals (Sweden)

    Liang Ma

    2015-09-01

    Full Text Available Pyrrolizidine alkaloids (PAs are hepatotoxic, genotoxic, and carcinogenic in experimental animals. Because of their widespread distribution in the world, PA-containing plants are probably the most common poisonous plants affecting livestock, wildlife, and humans. Upon metabolism, PAs generate reactive dehydro-PAs and other pyrrolic metabolites that lead to toxicity. Dehydro-PAs are known to react with glutathione (GSH to form 7-GSH-(+/−-6,7-dihydro-7-hydroxy-1-hydroxymethyl-5H-pyrrolizine (7-GS-DHP in vivo and in vitro and 7,9-diGS-DHP in vitro. To date, the phototoxicity of GS-DHP adducts has not been well studied. In this study, we synthesized 7-GS-DHP, a tentatively assigned 9-GS-DHP, and two enantiomeric 7,9-diGS-DHP adducts by reaction of dehydromonocrotaline with GSH. The two 7,9-diGS-DHPs were separated by high performance liquid chromatography (HPLC and their structures were characterized by 1H nuclear magnetic resonance (NMR and 1H–1H correlation spectroscopy (COSY NMR spectral analysis. Photoirradiation of 7-GS-DHP, 9-GS-DHP, and the two 7,9-diGS-DHPs as well as dehydromonocrotaline, dehydroheliotrine, and the 7-R enantiomer of DHP (DHR, by UVA light at 0 J/cm2, 14 J/cm2, and 35 J/cm2 in the presence of a lipid, methyl linoleate, all resulted in lipid peroxidation in a light dose-responsive manner. The levels of lipid peroxidation induced by the two isomeric 7,9-diGS-DHPs were significantly higher than that by 7-GS-DHP and 9-GS-DHP. When 7,9-diGS-DHP was irradiated in the presence of sodium azide (NaN3, the level of lipid peroxidation decreased; lipid peroxidation was enhanced when methanol was replaced by deuterated methanol. These results suggest that singlet oxygen is a product induced by the irradiation of 7,9-diGS-DHP. When irradiated in the presence of superoxide dismutase (SOD, the level of lipid peroxidation decreased, indicating that lipid peroxidation is also mediated by superoxide. These results indicate that lipid

  15. Examining Wrong Eye Implant Adverse Events in the Veterans Health Administration With a Focus on Prevention: A Preliminary Report.

    Science.gov (United States)

    Neily, Julia; Chomsky, Amy; Orcutt, James; Paull, Douglas E; Mills, Peter D; Gilbert, Christina; Hemphill, Robin R; Gunnar, William

    2018-03-01

    The study goals were to examine wrong intraocular lens (IOL) implant adverse events in the Veterans Health Administration (VHA), identify root causes and contributing factors, and describe system changes that have been implemented to address this challenge. This study represents collaboration between the VHA's National Center for Patient Safety (NCPS) and the National Surgery Office (NSO). This report includes 45 wrong IOL implant surgery adverse events reported to established VHA NCPS and NSO databases between July 1, 2006, and June 31, 2014. There are approximately 50,000 eye implant procedures performed each year in the VHA. Wrong IOL implant surgery adverse events are reported by VHA facilities to the NCPS and the NSO. Two authors (A.C. and J.N.) coded the reports for event type (wrong lens or expired lens) and identified the primary contributing factor (coefficient κ = 0.837). A descriptive analysis was conducted, which included the reported yearly event rate. The main outcome measure was the reported wrong IOL implant surgery adverse events. There were 45 reported wrong IOL implant surgery adverse events. Between 2011 and June 30, 2014, there was a significant downward trend (P = 0.02, R = 99.7%) at a pace of -0.08 (per 10,000 cases) every year. The most frequently coded primary contributing factor was incomplete preprocedure time-out (n = 12) followed by failure to perform double check of preprocedural calculations based upon original data and implant read-back at the time the surgical eye implant was performed (n = 10). Preventing wrong IOL implant adverse events requires diligence beyond performance of the preprocedural time-out. In 2013, the VHA has modified policy to ensure double check of preprocedural calculations and implant read-back with positive impact. Continued analysis of contributing human factors and improved surgical team communication are warranted.

  16. Nanosecond KTN varifocal lens without electric field induced phase transition

    Science.gov (United States)

    Zhu, Wenbin; Chao, Ju-Hung; Chen, Chang-Jiang; Campbell, Adrian; Henry, Michael; Yin, Stuart (Shizhuo); Hoffman, Robert C.

    2017-08-01

    This paper presents a nanosecond speed KTN varifocal lens. The tuning principle of varifocal lens is based on the high-speed refractive index modulation from the nanosecond speed tunable electric field. A response time on the order of nanoseconds was experimentally demonstrated, which is the fastest varifocal lens reported so far. The results confirmed that the tuning speed of the KTN varifocal lens could be significantly increased by avoiding the electric field induced phase transition. Such a nanosecond speed varifocal lens can be greatly beneficial for a variety of applications that demand high speed axial scanning, such as high-resolution 3D imaging and high-speed 3D printing.

  17. Anterior haptic flexing and in-the-bag subluxation of an accommodating intraocular lens due to excessive capsular bag contraction.

    Science.gov (United States)

    Kramer, Gregory D; Werner, Liliana; Neuhann, Tobias; Tetz, Manfred; Mamalis, Nick

    2015-09-01

    We describe the case of a patient who had cataract surgery with implantation of the hydrophilic acrylic Tetraflex accommodating intraocular lens (IOL), with subsequent development of capsulorhexis phimosis and in-the-bag IOL subluxation. Contraction of the capsular bag secondary to fibrosis resulted in significant anterior flexing of the lens haptic component. Explantation of the IOL-capsular bag complex was required 7 years after implantation. Histopathologic analysis demonstrated multiple areas of thick anterior subcapsular fibrosis. Pseudoexfoliative material was present throughout the surface of the lens capsule. Intraocular lenses manufactured from hydrophilic acrylic material are highly flexible and may be more susceptible to capsule contraction, even in the absence of predisposing ocular and systemic conditions. This case highlights the importance of developing guidelines regarding patient screening and selection for the appropriate use of accommodating and other highly flexible IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  18. Acid phosphatase and lipid peroxidation in human cataractous lens epithelium

    Directory of Open Access Journals (Sweden)

    Vasavada Abhay

    1993-01-01

    Full Text Available The anterior lens epithelial cells undergo a variety of degenerative and proliferative changes during cataract formation. Acid phosphatase is primarily responsible for tissue regeneration and tissue repair. The lipid hydroperoxides that are obtained by lipid peroxidation of polysaturated or unsaturated fatty acids bring about deterioration of biological membranes at cellular and tissue levels. Acid phosphatase and lipid peroxidation activities were studied on the lens epithelial cells of nuclear cataract, posterior subcapsular cataract, mature cataract, and mixed cataract. Of these, mature cataractous lens epithelium showed maximum activity for acid phosphatase (516.83 moles of p-nitrophenol released/g lens epithelium and maximum levels of lipid peroxidation (86.29 O.D./min/g lens epithelium. In contrast, mixed cataractous lens epithelium showed minimum activity of acid phosphatase (222.61 moles of p-nitrophenol released/g lens epithelium and minimum levels of lipid peroxidation (54.23 O.D./min/g lens epithelium. From our study, we correlated the maximum activity of acid phosphatase in mature cataractous lens epithelium with the increased areas of superimposed cells associated with the formation of mature cataract. Likewise, the maximum levels of lipid peroxidation in mature cataractous lens epithelium was correlated with increased permeability of the plasma membrane. Conversely, the minimum levels of lipid peroxidation in mixed cataractous lens epithelium makes us presume that factors other than lipid peroxidation may also account for the formation of mixed type of cataract.

  19. Oxygen transport through soft contact lens and cornea: Lens characterization and metabolic modeling

    Science.gov (United States)

    Chhabra, Mahendra

    The human cornea requires oxygen to sustain metabolic processes critical for its normal functioning. Any restriction to corneal oxygen supply from the external environment (e.g., by wearing a low oxygen-permeability contact lens) can lead to hypoxia, which may cause corneal edema (swelling), limbal hyperemia, neovascularization, and corneal acidosis. The need for adequate oxygen to the cornea is a major driving force for research and development of hypertransmissible soft contact lenses (SCLs). Currently, there is no standard technique for measuring oxygen permeability (Dk) of hypertransmissible silicone-hydrogel SCLs. In this work, an electrochemistry-based polarographic apparatus was designed, built, and operated to measure oxygen permeability in hypertransmissible SCLs. Unlike conventional methods where a range of lens thickness is needed for determining oxygen permeabilities of SCLs, this apparatus requires only a single lens thickness. The single-lens permeameter provides a reliable, efficient, and economic tool for measuring oxygen permeabilities of commercial hypertransmissible SCLs. The single-lens permeameter measures not only the product Dk, but, following modification, it measures separately diffusivity, D, and solubility, k, of oxygen in hypertransmissible SCLs. These properties are critical for designing better lens materials that ensure sufficient oxygen supply to the cornea. Metabolism of oxygen in the cornea is influenced by contact-lens-induced hypoxia, diseases such as diabetes, surgery, and drug treatment, Thus, estimation of the in-vivo corneal oxygen consumption rate is essential for gauging adequate oxygen supply to the cornea. Therefore, we have developed an unsteady-state reactive-diffusion model for the cornea-contact-lens system to determine in-vivo human corneal oxygen-consumption rate. Finally, a metabolic model was developed to determine the relation between contact-lens oxygen transmissibility (Dk/L) and corneal oxygen deficiency. A

  20. Subjective assessment of contact lens wear by army aircrew.

    Science.gov (United States)

    Lattimore, M R; Cornum, R L

    1993-07-01

    Because 23% of Army aviators are ametropic, contact lenses have drawn increased attention as a spectacle substitute to solve system compatibility problems. From November 1988 until October 1991, a series of contact lens research protocols were conducted to develop a comprehensive database on contact lens wear in varied environments. Questionnaires were used to assess suitability and acceptability of routine contact lens wear. Responses from 202 subjects were obtained from September 1989 through September 1991. The questions explored operational and safety of flight issues of contact lens wear. Subjects overwhelmingly approved of contact lens use in all settings: 95% expressed greater combat readiness and effectiveness with contact lenses, 98% felt contact lens use (and maintenance) in the cockpit had no adverse impact on safety of flight, and 98% endorsed the routine use of contact lenses. These data highlight Army aircrew acceptance of contact lens use.

  1. Lens Epithelial Cell Death Secondary to Acanthamoeba Keratitis: Absence of Capsular Bag Opacification Six Years after Cataract Surgery

    Directory of Open Access Journals (Sweden)

    Javier Moreno-Montañés

    2011-12-01

    Full Text Available Purpose: To show the evolution of anterior chamber structures 6 years after cataract surgery in a case with Acanthamoeba keratitis (AK. Methods: A 37-year-old woman with AK receiving long-term treatment with chlorhexidine, propamidine isethionate and steroids developed a white cataract and iris atrophy. Penetrating keratoplasty and cataract surgery were performed with subsequent intraocular pressure elevation requiring Molteno shunt implantation. Two years after the last surgery, endothelial decompensation developed and another penetrating keratoplasty was performed. Intraoperatively, the anterior and posterior capsules were completely transparent. Results: Six years after cataract surgery, the intraocular lens was centered with clear anterior and posterior capsules without lens epithelial cells proliferation. No Soemmering’s ring formation or posterior capsule opacification was found. Also, no zonular damage or pseudophacodonesis was observed. Conclusions: This case suggests that AK infection and AK treatment not only cause white progressive cataract but also lens epithelial cell death. The capsules may be completely clear 6 years after cataract surgery, with a good quality of vision regardless of intraocular lens material or design.

  2. Diagnostic Imaging for Implants

    Directory of Open Access Journals (Sweden)

    Sanjay M Mallya

    2004-01-01

    Full Text Available Dental implants are a popular modality for permanent tooth replacement. The key to successful implant placement, its subsequent osseointegration and the final prosthetic rehabilitation is proper preoperative assessment. Diagnostic imaging plays an important role in the pre- and post-surgical evaluation process. Imaging is used to evaluate suitability of implant sites, aid in selection of appropriate implants, and finally evaluate implant placement and osseointegration. This article reviews the role of diagnostic imaging in the various phases and the advantages and limitations of the numerous imaging modalities.

  3. Liposomal hypocrellin B as a potential photosensitizer for age-related macular degeneration: pharmacokinetics, photodynamic efficacy, and skin phototoxicity in vivo.

    Science.gov (United States)

    Li, Tinghui; Hou, Xiaobin; Deng, Hong; Zhao, Jingquan; Huang, Naiyan; Zeng, Jing; Chen, Hongxia; Gu, Ying

    2015-05-01

    Photodynamic therapy (PDT) has been successfully implemented as a treatment for wet age-related macular degeneration (AMD), but very few photosensitizers have been developed for clinical use. Herein, we describe a novel formulation of liposomal hypocrellin B (LHB) that was prepared by high-pressure homogenization. The encapsulation efficiency and PDT efficacy in vitro of this new preparation were found to remain nearly constant over 1 year. Moreover, LHB is rapidly cleared from the blood, with a half-life of 2.319 ± 0.462 h and a very low serum concentration at 24 h after injection. Testing in a rat model of choroidal neovascularization (CNV) showed that leakage of blood vessels in CNV lesions was significantly reduced when LHB PDT was given at a dose of 1 mg kg(-1) along with yellow laser irradiation; the damage to the collateral retina and the retinal pigment epithelium was minimal. Skin phototoxicity assays showed that only two of the 200 mice given a 4 mg per kg dose of LHB experienced an inflammatory reaction in the auricle irradiated at 24 h after dosing. These data collectively indicate that LHB may be a safe and effective photosensitizer for vascular-targeted PDT of AMD.

  4. Near-surface recrystallization of the amorphous implanted layer of ion implanted 6H-SiC

    Science.gov (United States)

    Kuhudzai, R. J.; van der Berg, N. G.; Malherbe, J. B.; Hlatshwayo, T. T.; Theron, C. C.; Buys, A. V.; Botha, A. J.; Wendler, E.; Wesch, W.

    2014-08-01

    The recrystallization and subsequent crystal growth during annealing of amorphous surface layers on 6H-SiC produced by ion implantation is investigated. Amorphous surface layers were produced by ion implantation of 360 keV ions of iodine, silver, xenon, cesium and strontium into single crystalline 6H-silicon carbide samples. The ion fluence for all the implantations were in the order of 1016 cm-2. Vacuum annealing of the damaged silicon carbide samples was then performed. The microstructure of SiC surfaces before and after annealing was investigated using a high resolution field emission scanning electron microscope (SEM). SEM analysis was complimented by Atomic Force Microscopy (AFM). SEM images acquired by an in-lens detector using an accelerating voltage of 2 kV show nano-crystallites developed for all implanted samples after annealing. Larger and more faceted crystallites along with elongated thin crystallites were observed for iodine and xenon implanted 6H-SiC. Crystallites formed on surfaces implanted with strontium and cesium were smaller and less faceted. Strontium, silver and cesium implanted samples also exhibited more cavities on the surface. AFM was used to evaluate the effect of annealing on the surface roughness. For all the amorphous surfaces which were essentially featureless, the root mean square (rms) roughness was approximately 1 nm. The roughness increased to approximately 17 nm for the iodine implanted sample after annealing with the surface roughness below this value for all the other samples. AFM also showed that the largest crystals grew to heights of about 17, 20, 45, 50 and 65 nm for Sr, Cs, Ag, Xe and I implanted samples after annealing at 1200 °C for 5 h respectively. SEM images and AFM analysis suggest that iodine is more effective in promoting crystal growth during the annealing of bombardment-induced amorphous SiC layers than the rest of the ions we implanted. In samples of silicon carbide co-implanted with iodine and silver, few

  5. Gravitational Lens Time Delays Using Polarization Monitoring

    Directory of Open Access Journals (Sweden)

    Andrew Biggs

    2017-11-01

    Full Text Available Gravitational lens time delays provide a means of measuring the expansion of the Universe at high redshift (and therefore in the ‘Hubble flow’ that is independent of local calibrations. It was hoped that many of the radio lenses found in the JVAS/CLASS survey would yield time delays as these were selected to have flat spectra and are dominated by multiple compact components. However, despite extensive monitoring with the Very Large Array (VLA, time delays have only been measured for three of these systems (out of 22. We have begun a programme to reanalyse the existing VLA monitoring data with the goal of producing light curves in polarized flux and polarization position angle, either to improve delay measurements or to find delays for new sources. Here, we present preliminary results on the lens system B1600+434 which demonstrate the presence of correlated and substantial polarization variability in each image.

  6. Complications caused by contact lens wearing.

    Science.gov (United States)

    Beljan, Jasna; Beljan, Kristina; Beljan, Zdravko

    2013-04-01

    Complications in wearing contact lenses are very rare and caused by poor maintenance, over-extended wear and wearing of contact lenses in a polluted environment. Regular control by a professional person can efficiently reduce the number of complications. This paper describes the most common risks factors for complications, and complications of wearing contact lenses with the classification according to the anatomic parts of the eye: eyelids, tear film, limbus, corneal epithelium, corneal stroma and corneal endothelium. Every complication has been described by the characteristic signs and symptoms, etiology and pathology, as well as therapy and prognosis. The paper describes how to select adequate customers as contact lens users, with proper education in order to ensure minimal incidence of complications due to contact lens wear, thus attracting a lot of satisfied and healthy customers.

  7. Effects of Temperature on Hybrid Lens Performance

    Science.gov (United States)

    Askins, Steve; Victoria, Marta; Herrero, Rebeca; Domínguez, César; Antón, Ignacio; Sala, Gabriel

    2011-12-01

    In hybrid Silicone-on-glass Fresnel lenses, an optical silicone is molded onto a glass substrate and forms the Fresnel structure. These lenses offer a cost effective solution as a primary optical element in point-focus concentrator photovoltaic modules, as well as performance advantages. However, these lenses have a high performance variation with temperature due both to the change in index of refraction of silicone as well as to deformations in the facets caused by coefficient of thermal expansion (CTE) mismatch. In this study we perform measurements of the light flux at the focal plane of a family of SOG lenses, varying temperature and lens-to-receiver distances. The effect of varying silicone cure temperature and the depth of the silicone between the lens and the glass substrate on temperature dependence was investigated. A preliminary computer model of this behavior is presented.

  8. A Tribute to Dr. Willy Lens

    Directory of Open Access Journals (Sweden)

    Maarten Vansteenkiste

    2016-07-01

    Full Text Available Dr. Willy Lens, born on December 10th, 1943, passed away on August 29th, 2014. With his passing, the motivation community has lost a seminal member, a mentor, and a friend. Dr. Lens – a Fellow of the Association for Psychological Science and Founding Fellow of the American Educational Research Association – made fundamental contributions to the study of motivation both through his own work and through his caring and thoughtful mentorship of a large community of scholars. With this tribute, we want to honor Dr. Willy Lens’ significance to psychology and education as well as his positive influence, both personally and professionally, on the lives of dozens of scholars. With his contagious enthusiasm and caring mentorship, Willy was an example for our academic community and with this tribute we express our gratitude for the privilege to have collaborated with him.

  9. Stretched Lens Array Photovoltaic Concentrator Technology Developed

    Science.gov (United States)

    Piszczor, Michael F., Jr.; O'Neill, Mark J.

    2004-01-01

    Solar arrays have been and continue to be the mainstay in providing power to nearly all commercial and government spacecraft. Light from the Sun is directly converted into electrical energy using solar cells. One way to reduce the cost of future space power systems is by minimizing the size and number of expensive solar cells by focusing the sunlight onto smaller cells using concentrator optics. The stretched lens array (SLA) is a unique concept that uses arched Fresnel lens concentrators to focus sunlight onto a line of high-efficiency solar cells located directly beneath. The SLA concept is based on the Solar Concentrator Array with Refractive Linear Element Technology (SCARLET) design that was used on NASA's New Millennium Deep Space 1 mission. The highly successful asteroid/comet rendezvous mission (1998 to 2001) demonstrated the performance and long-term durability of the SCARLET/SLA solar array design and set the foundation for further improvements to optimize its performance.

  10. Pulser for the Tevatron electron lens gun

    Energy Technology Data Exchange (ETDEWEB)

    Iouri Terechkine et al.

    2004-05-18

    To compensate for beam-beam interaction in Tevatron, an ''electron lens'' is considered to be an effective instrument. When a bunch of electrons with energy in the range (10-16) kV is overlapping with a bunch of antiprotons, the resulting focusing force for antiprotons can be adjusted by changing the electron beam current and by profiling its radial distribution. There exist several scenarios of how the system must function. According to one of them, an electron gun that supplies electrons must be fed by voltage pulses that follow with the frequency of antiproton bunches circulating in the Tevatron, which is about 2.5 MHz. To provide focusing tailored for each individual antiproton bunch, a modulator of the gun (pulser) must allow pulse-to-pulse voltage change. This report will cover main approaches to a design of a pulser for use with the gun of the Tevatron Electron Lens.

  11. Intraocular Lens Subluxation in Marfan Syndrome

    Science.gov (United States)

    Rodrigo, Bolaños-Jiménez; Paulina, López-Lizárraga E; Francesc, March de R; Eduardo, Telich-Tarriba J; Alejandro, Navas

    2014-01-01

    Purpose : Ectopia lentis (EL) is a major criteria for the diagnosis of Marfan syndrome, it may vary from an asymptomatic mild displacement to a significant subluxation that places the equator of the lens in the pupillary axis. The purpose of this work is to present the case of a patient with Marfan syndrome who received treatment for subluxation at our institution. Case Report : A 51-year-old female diagnosed with Marfan syndrome presented to the emergency department with bilateral eye redness, foreign body sensation and crusting around the eyes on awakening. She had the following history of cardiac and ophthalmologic complications, including: 1. Lens subluxation 2. High myopia 3. Aortic root dilation, 4. Mitral valve prolapse and 5. Tricuspid insufficiency. Conclusion : The ophthalmological management of Marfan patients is challenging and periodical follow-up is needed. Surgical versus conservative management is controversial, each case needs to be evaluated individually to analyze the risks and benefits of the procedures. PMID:25279020

  12. Sterilization potential of contact lens solutions

    OpenAIRE

    Dada Vijay; Mehta Manoj

    1988-01-01

    In a dynamic field of Contact Lens Solutions maintenance of high standards of anti-microbial activity is a must Resterilization Activity Time′ is a universally accepted yardstick for such an evaluation. In this study eight brands of indigenous popular solutions alongwith two FDA approved solutions were tested for their sterilization efficacy: Standardized suspensions of Pseudomonas aeruginosa, Staphylococcus aureus, Candida albicans and Aspergillus fumigatus were used for the purpose. ...

  13. Performance of a Be Refractive Lens

    International Nuclear Information System (INIS)

    Smither, R.K.; Khounsary, A.M.; Mancini, D.C.; Saleem, K. Abu

    2004-01-01

    The performance of a beryllium compound refractive lens (CRL) was tested in the energy range of 11.5 to 8.0 keV. The beryllium refractive lens consists of 50 aligned, 1-mm-diameter, hollow spheres in a solid block of beryllium, 30 mm x 20 mm x 55 mm. The minimum web between each hollow sphere was 0.10 mm. The measured focal length of the lens for x-rays close to the axis of the beam was 147.7 cm +/- 2.0 cm at 10 keV and 120.2 +/- 2.0 cm at 9.1 keV. These values agree well with the theoretical values of 146.6 cm and 121.4 cm, respectively. The diameter of the best focus obtained at 10 keV was 35 μm horizontal and 45 μm vertical. For the modified version of the lens used in the 9.1 keV experiment these values were 25 μm horizontal and 35 μm vertical. The x-ray beam cross section for the 10 keV and the 9.1 keV experiments were 0.50 mm x 0.50 mm and 0.30 mm x 0.30 mm, respectively. The enhancement of the flux (photons per sq. mm) was 50:1 at 10 keV and 80:1 in the 9.1 keV experiment

  14. THE BOSS EMISSION-LINE LENS SURVEY. IV. SMOOTH LENS MODELS FOR THE BELLS GALLERY SAMPLE

    Energy Technology Data Exchange (ETDEWEB)

    Shu, Yiping [National Astronomical Observatories, Chinese Academy of Sciences, 20A Datun Road, Chaoyang District, Beijing 100012 (China); Bolton, Adam S.; Montero-Dorta, Antonio D.; Cornachione, Matthew A.; Zheng, Zheng; Brownstein, Joel R. [Department of Physics and Astronomy, University of Utah, 115 South 1400 East, Salt Lake City, UT 84112 (United States); Mao, Shude [Physics Department and Tsinghua Centre for Astrophysics, Tsinghua University, Beijing 100084 (China); Kochanek, Christopher S. [Department of Astronomy and Center for Cosmology and Astroparticle Physics, Ohio State University, Columbus, OH 43210 (United States); Pérez-Fournon, Ismael; Marques-Chaves, Rui [Instituto de Astrofísica de Canarias, C/Vía Láctea, s/n, E-38205 San Cristóbal de La Laguna, Tenerife (Spain); Oguri, Masamune [Research Center for the Early Universe, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Ménard, Brice, E-mail: yiping.shu@nao.cas.cn [Department of Physics and Astronomy, Johns Hopkins University, Baltimore, MD 21218 (United States)

    2016-12-20

    We present Hubble Space Telescope F606W-band imaging observations of 21 galaxy-Ly α emitter lens candidates in the Baryon Oscillation Spectroscopic Survey Emission-Line Lens Survey (BELLS) for the GALaxy-Ly α EmitteR sYstems (BELLS GALLERY) survey. Seventeen systems are confirmed to be definite lenses with unambiguous evidence of multiple imaging. The lenses are primarily massive early-type galaxies (ETGs) at redshifts of approximately 0.55, while the lensed sources are Ly α emitters (LAEs) at redshifts from two to three. Although most of the lens systems are well fit by smooth lens models consisting of singular isothermal ellipsoids in an external shear field, a thorough exploration of dark substructures in the lens galaxies is required. The Einstein radii of the BELLS GALLERY lenses are, on average, 60% larger than those of the BELLS lenses because of the much higher source redshifts. This will allow for a detailed investigation of the radius evolution of the mass profile in ETGs. With the aid of the average ∼13× lensing magnification, the LAEs are frequently resolved into individual star-forming knots with a wide range of properties. They have characteristic sizes from less than 100 pc to several kiloparsecs, rest-frame far-UV apparent AB magnitudes from 29.6 to 24.2, and typical projected separations of 500 pc to 2 kpc.

  15. Two families of astrophysical diverging lens models

    Science.gov (United States)

    Er, Xinzhong; Rogers, Adam

    2018-03-01

    In the standard gravitational lensing scenario, rays from a background source are bent in the direction of a foreground lensing mass distribution. Diverging lens behaviour produces deflections in the opposite sense to gravitational lensing, and is also of astrophysical interest. In fact, diverging lensing due to compact distributions of plasma has been proposed as an explanation for the extreme scattering events that produce frequency-dependent dimming of extragalactic radio sources, and may also be related to the refractive radio wave phenomena observed to affect the flux density of pulsars. In this work we study the behaviour of two families of astrophysical diverging lenses in the geometric optics limit, the power law, and the exponential plasma lenses. Generally, the members of these model families show distinct behaviour in terms of image formation and magnification, however the inclusion of a finite core for certain power-law lenses can produce a caustic and critical curve morphology that is similar to the well-studied Gaussian plasma lens. Both model families can produce dual radial critical curves, a novel distinction from the tangential distortion usually produced by gravitational (converging) lenses. The deflection angle and magnification of a plasma lens vary with the observational frequency, producing wavelength-dependent magnifications that alter the amplitudes and the shape of the light curves. Thus, multiwavelength observations can be used to physically constrain the distribution of the electron density in such lenses.

  16. Dynamic metasurface lens based on MEMS technology

    Directory of Open Access Journals (Sweden)

    Tapashree Roy

    2018-02-01

    Full Text Available In the recent years, metasurfaces, being flat and lightweight, have been designed to replace bulky optical components with various functions. We demonstrate a monolithic Micro-Electro-Mechanical System (MEMS integrated with a metasurface-based flat lens that focuses light in the mid-infrared spectrum. A two-dimensional scanning MEMS platform controls the angle of the lens along two orthogonal axes by ±9°, thus enabling dynamic beam steering. The device could be used to compensate for off-axis incident light and thus correct for aberrations such as coma. We show that for low angular displacements, the integrated lens-on-MEMS system does not affect the mechanical performance of the MEMS actuators and preserves the focused beam profile as well as the measured full width at half maximum. We envision a new class of flat optical devices with active control provided by the combination of metasurfaces and MEMS for a wide range of applications, such as miniaturized MEMS-based microscope systems, LIDAR scanners, and projection systems.

  17. Adaptive Liquid Lens Actuated by Droplet Movement

    Directory of Open Access Journals (Sweden)

    Chao Liu

    2014-08-01

    Full Text Available In this paper we report an adaptive liquid lens actuated by droplet movement. Four rectangular PMMA (Polymethyl Methacrylate substrates are stacked to form the device structure. Two ITO (Indium Tin Oxide sheets stick on the bottom substrate. One PMMA sheet with a light hole is inserted in the middle of the device. A conductive droplet is placed on the substrate and touches the PMMA sheet to form a small closed reservoir. The reservoir is filled with another immiscible non-conductive liquid. The non-conductive liquid can form a smooth concave interface with the light hole. When the device is applied with voltage, the droplet stretches towards the reservoir. The volume of the reservoir reduces, changing the curvature of the interface. The device can thus achieve the function of an adaptive lens. Our experiments show that the focal length can be varied from −10 to −159 mm as the applied voltage changes from 0 to 65 V. The response time of the liquid lens is ~75 ms. The proposed device has potential applications in many fields such as information displays, imaging systems, and laser scanning systems.

  18. Thin wetting film lens-less imaging

    International Nuclear Information System (INIS)

    Allier, C.P.; Poher, V.; Coutard, J.G.; Hiernard, G.; Dinten, J.M.

    2011-01-01

    Lens-less imaging has recently attracted a lot of attention as a compact, easy-to-use method to image or detect biological objects like cells, but failed at detecting micron size objects like bacteria that often do not scatter enough light. In order to detect single bacterium, we have developed a method based on a thin wetting film that produces a micro-lens effect. Compared with previously reported results, a large improvement in signal to noise ratio is obtained due to the presence of a micro-lens on top of each bacterium. In these conditions, standard CMOS sensors are able to detect single bacterium, e.g. E. coli, Bacillus subtilis and Bacillus thuringiensis, with a large signal to noise ratio. This paper presents our sensor optimization to enhance the SNR; improve the detection of sub-micron objects; and increase the imaging FOV, from 4.3 mm 2 to 12 mm 2 to 24 mm 2 , which allows the detection of bacteria contained in 0.5 μl to 4 μl to 10 μl, respectively. (authors)

  19. Compound refractive X-ray lens

    International Nuclear Information System (INIS)

    Nygren, D.R.; Cahn, R.; Cederstrom, B.; Danielsson, M.; Vestlund, J.

    2000-01-01

    An apparatus and method are disclosed for focusing X-rays. In one embodiment, his invention is a commercial-grade compound refractive X-ray lens. The commercial-grade compound refractive X-ray lens includes a volume of low-Z material. The volume of low-Z material has a first surface which is adapted to receive X-rays of commercially-applicable power emitted from a commercial-grade X-ray source. The volume of low-Z material also has a second surface from which emerge the X-rays of commercially-applicable power which were received at the first surface. Additionally, the commercial-grade compound refractive X-ray lens includes a plurality of openings which are disposed between the first surface and the second surface. The plurality of openings are oriented such that the X-rays of commercially-applicable power which are received at the first surface, pass through the volume of low-Z material and through the plurality openings. In so doing, the X-rays which emerge from the second surface are refracted to a focal point

  20. Laboratory Demonstration of Axicon-Lens Coronagraph

    Science.gov (United States)

    Choi, Jaeho; Jea, Geonho

    2018-01-01

    The results of laboratory based experiments of the proposed coronagraph using axicon-lenses that is conjunction with a method of noninterferometric quantitative phase imaging for direct imaging of exoplanets is will present. The light source is passing through tiny holes drilled on the thin metal plate is used as the simulated stellar and its companions. Those diffracted light at the edge of the holes bears a similarity to the light from the bright stellar. Those images are evaginated about the optical axis after the maximum focal length of the first axicon lens. Then the evaginated images of have cut off using the motorized iris which means the suppressed the central stellar light preferentially. Various length between the holes which represent the angular distance are examined. The laboratory experimental results are shown that the axicon-lens coronagraph has feature of ability to achieve the smaller IWA than l/D and high-contrast direct imaging. The laboratory based axicon-lens coronagraph imaging support the symbolic computation results which has potential in direct imaging for finding exoplanet and various astrophysical activities. The setup of the coronagraph is simple to build and is durable to operate. Moreover it can be transported the planets images to a broadband spectrometric instrument that able to investigate the constituent of the planetary system.

  1. Metasurface axicon lens design at visible wavelengths

    Science.gov (United States)

    Alyammahi, Saleimah; Zhan, Qiwen

    2017-08-01

    The emerging field of metasurfaces is promising to realize novel optical devices with miniaturized flat format and added functionalities. Metasurfaces have been demonstrated to exhibit full control of amplitude, phase and polarization of electromagnetic waves. Using the metasurface, the wavefront of light can be manipulated permitting new functionalities such as focusing and steering of the beams and imaging. One optical component which can be designed using metasurfaces is the axicon. Axicons are conical lenses used to convert Gaussian beams into nondiffraction Bessel beams. These unique devices are utilized in different applications ranging from optical trapping and manipulation, medical imaging, and surgery. In this work, we study axicon lens design comprising of planar metasurfaces which generate non-diffracting Bessel beams at visible wavelengths. Dielectric metasurfaces have been used to achieve high efficiency and low optical loss. We measured the spot size of the resulted beams at different planes to demonstrate the non-diffraction properties of the resulted beams. We also investigated how the spot size is influenced by the axicon aperture. Furthermore, we examined the achromatic properties of the designed axicon. Comparing with the conventional lens, the metasurface axicon lens design enables the creation of flat optical device with wide range of depth of focus along its optical axis.

  2. Radiation dose to the eye lens

    DEFF Research Database (Denmark)

    Baun, Christina; Falch Braas, Kirsten; D. Nielsen, Kamilla

    2015-01-01

    Radiation Dose to the Eye Lens: Does Positioning Really Matter? C. Baun1, K. Falch1, K.D. Nielsen2, S. Shanmuganathan1, O. Gerke1, P.F. Høilund-Carlsen1 1Department of Nuclear Medicine, Odense University Hospital, Odense C, Denmark. 2University College Lillebaelt, Odense, Denmark. Aim: The scan...... field in oncology patients undergoing eyes-to-thighs PET/CT must always include the base of the scull according to department guidelines. The eye lens is sensitive to radiation exposure and if possible it should be avoided to scan the eye. If the patient’s head is kipped backwards during the scan one...... might avoid including the eye in the CT scan without losing sufficient visualization of the scull base. The aim of this study was to evaluate the possibility of decreasing the radiation dose to the eye lens, simply by changing the head position, when doing the PET/CT scan from the base of the scull...

  3. Dynamic metasurface lens based on MEMS technology

    Science.gov (United States)

    Roy, Tapashree; Zhang, Shuyan; Jung, Il Woong; Troccoli, Mariano; Capasso, Federico; Lopez, Daniel

    2018-02-01

    In the recent years, metasurfaces, being flat and lightweight, have been designed to replace bulky optical components with various functions. We demonstrate a monolithic Micro-Electro-Mechanical System (MEMS) integrated with a metasurface-based flat lens that focuses light in the mid-infrared spectrum. A two-dimensional scanning MEMS platform controls the angle of the lens along two orthogonal axes by ±9°, thus enabling dynamic beam steering. The device could be used to compensate for off-axis incident light and thus correct for aberrations such as coma. We show that for low angular displacements, the integrated lens-on-MEMS system does not affect the mechanical performance of the MEMS actuators and preserves the focused beam profile as well as the measured full width at half maximum. We envision a new class of flat optical devices with active control provided by the combination of metasurfaces and MEMS for a wide range of applications, such as miniaturized MEMS-based microscope systems, LIDAR scanners, and projection systems.

  4. Radiation dose to the lens and cataract formation

    International Nuclear Information System (INIS)

    Henk, J.M.; Whitelocke, R.A.F.; Warrington, A.P.; Bessell, E.M.

    1993-01-01

    The purpose of this work was to determine the radiation tolerance of the lens of the eye and the incidence of radiation-induced lens changes in patients treated by fractionated supervoltage radiation therapy for orbital tumors. Forty patients treated for orbital lymphoma and pseudotumor with tumor doses of 20--40 Gy were studied. The lens was partly shielded using lead cylinders in most cases. The dose to the germinative zone of the lens was estimated by measurements in a tissue equivalent phantom using both film densitometry and thermoluminescent dosimetry. Opthalmological examination was performed at 6 monthly intervals after treatment. The lead shield was found to reduce the dose to the germinative zone of the lens to between 36--50% of the tumor dose for Cobalt beam therapy, and to between 11--18% for 5 MeV x-rays. Consequently, the lens doses were in the range 4.5--30 Gy in 10--20 fractions. Lens opacities first appeared from between 3 and 9 years after irradiation. Impairment of visual acuity ensued in 74% of the patients who developed lens opacities. The incidence of lens changes was strongly dose-related. None was seen after doses of 5 Gy or lower, whereas doses of 16.5 Gy or higher were all followed by lens opacities which impaired visual acuity. The largest number of patients received a maximum lens dose of 15 Gy; in this group the actuarial incidence of lens opacities at 8 years was 57% with visual impairment in 38%. The adult lens can tolerate a total dose of 5 Gy during a fractionated course of supervoltage radiation therapy without showing any changes. Doses of 16.5 Gy or higher will almost invariably lead to visual impairment. The dose which causes a 50% probability of visual impairment is approximately 15 Gy. 10 refs., 4 figs., 1 tab

  5. Novel Scanning Lens Instrument for Evaluating Fresnel Lens Performance: Equipment Development and Initial Results (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Herrero, R.; Miller, D. C.; Kurtz, S. R.; Anton, I.; Sala, G.

    2013-07-01

    A system dedicated to the optical transmittance characterization of Fresnel lenses has been developed at NREL, in collaboration with the UPM. The system quantifies the optical efficiency of the lens by generating a performance map. The shape of the focused spot may also be analyzed to understand change in the lens performance. The primary instrument components (lasers and CCD detector) have been characterized to confirm their capability for performing optical transmittance measurements. Measurements performed on SoG and PMMA lenses subject to a variety of indoor conditions (e.g., UV and damp heat) identified differences in the optical efficiency of the evaluated lenses, demonstrating the ability of the Scanning Lens Instrument (SLI) to distinguish between the aged lenses.

  6. A high excitation magnetic quadrupole lens quadruplet incorporating a single octupole lens for a low spherical aberration probe forming lens system

    Science.gov (United States)

    Dou, Yanxin; Jamieson, David N.; Liu, Jianli; Li, Liyi

    2018-03-01

    This paper describes the design of a new probe forming lens system consisting of a high excitation magnetic quadrupole lens quadruplet that incorporates a single magnetic octupole lens. This system achieves both a high demagnification and a low spherical aberration compared to conventional high excitation systems and is intended for deployment for the Harbin 300 MeV proton microprobe for applications in space science and ion beam therapy. This relative simplicity of the ion optical design to include a single octupole lens minimizes the risks associated with the constructional and operational precision usually needed for the probe forming lens system and this system could also be deployed in microprobe systems that operate with less magnetically rigid ions. The design of the new system is validated with reference to two independent ion optical computer codes.

  7. The neutron silicon lens. An update of the thermal neutron lens results

    International Nuclear Information System (INIS)

    Johnson, M.W.; Daymond, M.R.

    2001-01-01

    This paper introduces the concept of the Neutron Silicon Lens (NSL) and provides and update on the experimental results achieved to date. The NSL design is a cylindrical neutron lens based on the use of multiple neutron mirrors supported and separated by silicon wafers. Such lenses would have many applications in both the primary and scattered beams on neutron instruments, and would lead to immediate improvements where the sample to be illuminated is small, as in high pressure or engineering strain scanning instruments. (author)

  8. Forensic Analysis of a Contact Lens in a Murder Case.

    Science.gov (United States)

    Zwerling, Charles S

    2016-03-01

    Contact lenses have had rare relevance in trials and/or investigations. After 5 years of burial, orbital remnants were retrieved from an exhumed body and subsequently identified as a key piece of material evidence in a murder trial. The exhumed case materials were evaluated under laboratory conditions and were determined to be contact lens remnants. Contact lens fracture and burial simulation studies were performed to provide additional corroboration of the physical findings of the exhumed contact lens remnants. This material evidence was instrumental in providing factual proof refuting the defendant's testimony in the murder trial. A brief history of contact lens composition and use is provided for understanding the methods and observational results. This forensic case study represents the first published documentation of a contact lens from an exhumed body being used in a murder investigation and establishes an operational procedure for future forensic contact lens examinations. © 2016 American Academy of Forensic Sciences.

  9. HA-Coated Implant

    DEFF Research Database (Denmark)

    Daugaard, Henrik; Søballe, Kjeld; Bechtold, Joan E

    2014-01-01

    The goal of osseointegration of orthopedic and dental implants is the rapid achievement of a mechanically stable and long lasting fixation between living bone and the implant surface. In total joint replacements of cementless designs, coatings of calcium phosphates were introduced as a means...... of improving the fixation of implants. Of these, hydroxyapatite (HA) is the most widely used and most extensively investigated. HA is highly osseoconductive, and the positive effect is well documented in both basic and long-term clinical research [1–6]. This chapter describes experimental and clinical studies...... evaluating bone-implant fixation with HA coatings....

  10. Ion implantation technology

    CERN Document Server

    Downey, DF; Jones, KS; Ryding, G

    1993-01-01

    Ion implantation technology has made a major contribution to the dramatic advances in integrated circuit technology since the early 1970's. The ever-present need for accurate models in ion implanted species will become absolutely vital in the future due to shrinking feature sizes. Successful wide application of ion implantation, as well as exploitation of newly identified opportunities, will require the development of comprehensive implant models. The 141 papers (including 24 invited papers) in this volume address the most recent developments in this field. New structures and possible approach

  11. Lens regeneration in mice under the influence of vitamin A

    Indian Academy of Sciences (India)

    The effect of vitamin A has been studied on lens regeneration in young (7 days old) as well as adult mice. A longitudinal slit was made under local anesthesia in the cornea over the lens. The lens was extracted intact through the incision. Intraperitonial injection of vitamin A (0.05 ml of 30 IU/ml in young and 0.05 ml of 50 ...

  12. Subcontact Lens Bubble Formation under Low Atmospheric Pressure Conditions.

    Science.gov (United States)

    1986-08-01

    of subcontact lens bubble formation under scleral lenses at altitudes greater than 18,000 ft. Later, after many advances in contact lens fitting and...Reported here are the results of contact lens bubble studies with soft hydrophilic nd rigid gas-permeable lenses . Testing was accomplished in simulated...ccurred at altitudes greater than 20,000 ft. For soft contact lenses , bubble formation was etected in 22 of 92 eyes tested, and occurred at altitudes

  13. Haemophilus influenzae corneal ulcer in a therapeutic contact lens wearer.

    OpenAIRE

    Armstrong, J. R.; Cohen, K. L.; McCarthy, L. R.

    1984-01-01

    Haemophilus influenzae is an unusual corneal pathogen and an unusual cause of corneal ulcers in Western society. In previous reports corneal complications from H. influenzae have been secondary to a conjunctivitis. The first case of a primary H. influenzae corneal ulcer as a complication of therapeutic contact lens wear is presented. Since other uncommon bacteria have been reported as causes of contact lens related corneal ulcers, the bacteriology of contact lens related corneal ulcers is rev...

  14. Measurement of nonlinear optical refraction of composite material based on sapphire with silver by Kerr-lens autocorrelation method.

    Science.gov (United States)

    Yu, Xiang-xiang; Wang, Yu-hua

    2014-01-13

    Silver nanoparticles synthesized in a synthetic sapphire matrix were fabricated by ion implantation using the metal vapor vacuum arc ion source. The optical absorption spectrum of the Ag: Al2O3 composite material has been measured. The analysis of the supercontinuum spectrum displayed the nonlinear refractive property of this kind of sample. Nonlinear optical refraction index was identified at 800 nm excitation using the Kerr-lens autocorrelation (KLAC) technique. The spectrum showed that the material possessed self-defocusing property (n(2) = -1.1 × 10(-15) cm(2)W). The mechanism of nonlinear refraction has been discussed.

  15. Glued intrascleral fixation of posterior chamber intraocular lens in children.

    Science.gov (United States)

    Kumar, Dhivya Ashok; Agarwal, Amar; Prakash, Dimple; Prakash, Gaurav; Jacob, Soosan; Agarwal, Athiya

    2012-04-01

    To evaluate the short-term results of glued intrascleral fixation of posterior chamber intraocular lens (glued IOL) in children without adequate capsular support. Noncomparative retrospective observational case series. Institutional practice. Forty-one eyes of 33 children who underwent glued IOL implantation were retrospectively evaluated. The indications were postsurgical aphakia, subluxated cataract, ectopia lentis, traumatic subluxation, and decentered IOL. Visual acuity (VA), endothelial cell changes, intraoperative and postoperative complications. The mean age at the time of glued IOL was 10.7±3.6 years (range 5-15). The mean duration of follow-up after surgery was 17.5±8.5 months (range 12-36). The mean postoperative best spectacle-corrected visual acuity (BCVA in decimal equivalent) was 0.43±0.33 and there was significant change noted (P20/60 BCVA was obtained in 17.1% and 46.3% of eyes respectively. BCVA improvement more than 1 line was seen in 22 eyes (53.6%). The mean postoperative refraction was myopic (-1.19±0.7 diopters [D]) in 19 eyes and hyperopic (+1.02±0.7 D) in 22 eyes. The mean endothelial loss was 4.13% (range 1.3%-5.94%). The 3 causes of reduced BCVA were the preexisting corneal, retinal pathology, and amblyopia. Postoperative complications included optic capture in 1 eye (2.4%), macular edema in 2 eyes (4.8%), and clinical decentration in 2 eyes (4.8%). There was no postoperative retinal detachment, IOL dislocation, endophthalmitis, or glaucoma. Short-term results in children after glued IOL were favorable, with a low rate of complications. However, regular follow-ups are required since long-term risks are unknown. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. Disposable contact lenses vs. contact lens maintenance for extended wear.

    Science.gov (United States)

    Josephson, J E; Caffery, B E; Campbell, I; Slomovic, A R

    1990-01-01

    We compared a disposable extended wear contact lens modality with conventional extended wear over a 6-week period. To do so, we refit 31 patients who had successfully worn conventional extended wear contact lenses for more than 1 year. One eye was fit with the AcuvueR disposable contact lens, and a new extended wear lens of the type the patient had been wearing was placed on the other eye. At weekly intervals the disposable lens was discarded and a new disposable lens inserted. At the same time, the conventional lens on the fellow eye was cleaned, disinfected, and reinserted. After 6 weeks the ocular response, subjective impressions, and condition of the lenses in the two eyes were compared. Both lenses were then cultured. Three subjects had to discontinue disposable lens wear because of adverse reactions to trapped cellular debris and corneal microcysts. Although the results were not statistically significant, the Acuvue lens appeared to perform better than or equal to the conventional lens in biomicroscopic observation, visual acuity measurement, and subjective patient preference. Eighty-seven percent of patients preferred to continue with the disposable system. There were no differences found in the type or degree of microbial contamination of the lenses.

  17. Further studies of contact lens motion during blinking.

    Science.gov (United States)

    Conway, H D; Knoll, H A

    1986-10-01

    Contact lens motion is felt to be of increasing importance in connection with debris elimination, particularly in extended wear lenses. Thus an improved analysis is made of a simple model for investigating the initial motion of a hard contact lens over the eye during blinking. It is shown that the assumption of constant tear film thickness is a reasonable one. This greatly simplifies the analysis. Various vertical force vs. time variations are considered and lens velocity/time graphs and maximum lens displacement calculated. These are in good agreement with the results of experiment.

  18. Geometry-invariant gradient refractive index lens: analytical ray tracing.

    Science.gov (United States)

    Bahrami, Mehdi; Goncharov, Alexander V

    2012-05-01

    A new class of gradient refractive index (GRIN) lens is introduced and analyzed. The interior iso-indicial contours mimic the external shape of the lens, which leads to an invariant geometry of the GRIN structure. The lens model employs a conventional surface representation using a coincoid of revolution with a higher-order aspheric term. This model has a unique feature, namely, it allows analytical paraxial ray tracing. The height and the angle of an arbitrary incident ray can be found inside the lens in a closed-form expression, which is used to calculate the main optical characteristics of the lens, including the optical power and third-order monochromatic aberration coefficients. Moreover, due to strong coupling of the external surface shape to the GRIN structure, the proposed GRIN lens is well suited for studying accommodation mechanism in the eye. To show the power of the model, several examples are given emphasizing the usefulness of the analytical solution. The presented geometry-invariant GRIN lens can be used for modeling and reconstructing the crystalline lens of the human eye and other types of eyes featuring a GRIN lens.

  19. Particle swarm optimization applied to automatic lens design

    Science.gov (United States)

    Qin, Hua

    2011-06-01

    This paper describes a novel application of Particle Swarm Optimization (PSO) technique to lens design. A mathematical model is constructed, and merit functions in an optical system are employed as fitness functions, which combined radiuses of curvature, thicknesses among lens surfaces and refractive indices regarding an optical system. By using this function, the aberration correction is carried out. A design example using PSO is given. Results show that PSO as optical design tools is practical and powerful, and this method is no longer dependent on the lens initial structure and can arbitrarily create search ranges of structural parameters of a lens system, which is an important step towards automatic design with artificial intelligence.

  20. Acoustic Luneburg lens using orifice-type metamaterial unit cells

    Science.gov (United States)

    Park, Choon Mahn; Lee, Sang Hun

    2018-02-01

    A two-dimensional acoustic Luneburg lens that can be easily expanded into a three-dimensional sphere is fabricated. The required spatial distribution of the refractive index for this Luneburg lens is realized using the characteristics of orifice-type metamaterial unit cells. Typical characteristics of the resulting acoustic Luneburg lens, such as its aberration-free performance and capability for antipodal focusing of the lens for the incident plane waves, are investigated through experiments and simulations with the attenuation loss at frequencies that satisfy the homogeneous medium condition of the metamaterial. With the designed metamaterial, we achieved the minimum spot that lies within the classical diffraction limit at the focal point.