WorldWideScience

Sample records for length-to-diameter ratio emphasis

  1. The study on length and diameter ratio of nail as preliminary design for slope stabilization

    Science.gov (United States)

    Gunawan, Indra; Silmi Surjandari, Niken; Muslih Purwana, Yusep

    2017-11-01

    Soil nailing technology has been widely applied in practice for reinforced slope. The number of studies for the effective design of nail-reinforced slopes has also increased. However, most of the previous study was focused on a safety factor of the slope; the ratio of length and diameter itself has likely never been studied before. The aim of this study is to relate the length and diameter ratio of the nail with the safety factor of the 20 m height of sand slope in the various angle of friction and steepness of the slope. Simplified Bishop method was utilized to analyze the safety factor of the slope. This study is using data simulation to calculate the safety factor of the slope with soil nailing reinforcement. The results indicate that safety factor of slope stability increases with the increase of length and diameter ratio of the nail. At any angle of friction and steepness of the slope, certain effective length and diameter ratio was obtain. These results may be considered as a preliminary design for slope stabilization.

  2. Influence of length-to-diameter ratio on shrinkage of basalt fiber concrete

    Science.gov (United States)

    Ruijie, MA; Yang, Jiansen; Liu, Yuan; Zheng, Xiaojun

    2017-09-01

    In order to study the shrinkage performance of basalt concrete, using the shrinkage rate as index, the work not only studied the influence of different length-to-diameter ratio (LDR) on plastic shrinkage and drying shrinkage of basalt fiber concrete, but also analyzed the action mechanism. The results show that when the fiber content is 0.1%, the LDR of 800 and 1200 take better effects on reducing plastic shrinkage, however the fiber content is 0.3%, that of LDR 600 is better. To improve drying shrinkage, the fiber of LDR 800 takes best effect. In the concrete structure, the adding basalt fibers form a uniform and chaotic supporting system, optimize the pore and the void structure of concrete, make the material further compacted, reduce the water loss, so as to decrease the shrinkage of concrete effectively.

  3. Usefulness of left ventricular wall thickness-to-diameter ratio in thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Manno, B.; Hakki, A.H.; Kane, S.A.; Iskandrian, A.S.

    1983-01-01

    The ratio of left ventricular wall thickness to the cavity dimension, as seen on thallium-201 images, was used in this study to predict left ventricular ejection fraction and volume. We obtained rest thallium-201 images in 50 patients with symptomatic coronary artery disease. The thickness of a normal-appearing segment of the left ventricular wall and the transverse diameter of the cavity were measured in the left anterior oblique projection. The left ventricular ejection fraction and volume in these patients were determined by radionuclide ventriculography. There was a good correlation between thickness-to-diameter ratio and ejection fraction and end-systolic volume. In 18 patients with a thickness-to-diameter ratio less than 0.70, the ejection fraction was lower than in the 16 patients with thickness-to-diameter ratio greater than or equal to 1.0. Similarly, in patients with a thickness-to-diameter ratio less than 0.70, the end-diastolic and end-systolic volume were higher than in the remaining patients with higher thickness-to-diameter ratios. All 18 patients with a thickness-to-diameter ratio less than 0.70 had ejection fractions less than 40%; 14 of 15 patients with a thickness-to-diameter ratio greater than or equal to 1.0 had an ejection fraction greater than 40%. The remaining 16 patients with a thickness-to-diameter ratio of 0.7-0.99 had intermediate ejection fractions and volumes.(ABSTRACT TRUNCATED AT 250 WORDS)

  4. The silver nanowires synthesized using different molecule weight of polyvinyl pyrrolidone for controlling diameter and length by one-pot polyol method

    Energy Technology Data Exchange (ETDEWEB)

    Junaidi, E-mail: junaidi.1982@fmipa.unila.ac.id [Departement of Physics, Universitas Gadjah Mada, Yogyakarta, 55281 (Indonesia); Departement of Physics, Lampung University, Bandar Lampung (Indonesia); Triyana, K., E-mail: triyana@ugm.ac.id; Suharyadi, E.; Harsojo [Departement of Physics, Universitas Gadjah Mada, Yogyakarta, 55281 (Indonesia); Nanomaterials Research Group, Universitas Gadjah Mada, Yogyakarta, 55281 (Indonesia); Hui, H.; Wu, L. Y. L., E-mail: ylwu@simtech.a-star.edu.sg [Singapore Institute of Manufacturing Technology, 71 Nanyang Drive, Singapore 638075 (Singapore)

    2016-06-17

    In this paper, we report our investigation on the effect of the molecular weight and molar ratio of polyvinyl pyrrolidone (PVP) and silver nitrate (AgNO{sub 3}) for controlling diameter and length of the silver nanowires synthesized with a high-aspect-ratio. The silver nanowires synthesized by one-pot polyol method at a constant temperature oil bath of 130°C. Different molecule weights of PVP, i.e. 55 K, 360 K, and 1300 K were used combined with different molar ratios of [PVP:Ag]. The UV–vis spectrophotometry and Field-emission scanning electron microscopy (FE-SEM) were employed to characterize the silver nanowires. The results show that the molecular weight and molar ratio of [PVP:Ag] are very important for controlling growth and properties of the silver nanowires. The diameter and length of silver nanowires are obtained 80 to 140 nm and 30 to 70 µm, respectively. The higher molecular weight of PVP, the greater diameter and length of silver nanowires.

  5. The silver nanowires synthesized using different molecule weight of polyvinyl pyrrolidone for controlling diameter and length by one-pot polyol method

    International Nuclear Information System (INIS)

    Junaidi; Triyana, K.; Suharyadi, E.; Harsojo; Hui, H.; Wu, L. Y. L.

    2016-01-01

    In this paper, we report our investigation on the effect of the molecular weight and molar ratio of polyvinyl pyrrolidone (PVP) and silver nitrate (AgNO 3 ) for controlling diameter and length of the silver nanowires synthesized with a high-aspect-ratio. The silver nanowires synthesized by one-pot polyol method at a constant temperature oil bath of 130°C. Different molecule weights of PVP, i.e. 55 K, 360 K, and 1300 K were used combined with different molar ratios of [PVP:Ag]. The UV–vis spectrophotometry and Field-emission scanning electron microscopy (FE-SEM) were employed to characterize the silver nanowires. The results show that the molecular weight and molar ratio of [PVP:Ag] are very important for controlling growth and properties of the silver nanowires. The diameter and length of silver nanowires are obtained 80 to 140 nm and 30 to 70 µm, respectively. The higher molecular weight of PVP, the greater diameter and length of silver nanowires.

  6. A study of the heated length to diameter effects

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Ho; Baek, Won Pil; Chang, Soon Heung [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)

    1998-12-31

    An analytical and experimental investigation has been performed on the heated length-to-diameter effect on critical heat flux exit conditions. A L/D correction factor is developed by applying artificial neural network and conventional regression techniques to the KAIST CHF data base. In addition, experiment is being performed to validate the developed L/D correction factor with independent data. Assessment shows that the developed correction factor is promising for practical applications. 6 refs., 8 figs. (Author)

  7. A study of the heated length to diameter effects

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Ho; Baek, Won Pil; Chang, Soon Heung [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)

    1997-12-31

    An analytical and experimental investigation has been performed on the heated length-to-diameter effect on critical heat flux exit conditions. A L/D correction factor is developed by applying artificial neural network and conventional regression techniques to the KAIST CHF data base. In addition, experiment is being performed to validate the developed L/D correction factor with independent data. Assessment shows that the developed correction factor is promising for practical applications. 6 refs., 8 figs. (Author)

  8. Allowable pillar to diameter ratio for strategic petroleum reserve caverns.

    Energy Technology Data Exchange (ETDEWEB)

    Ehgartner, Brian L.; Park, Byoung Yoon

    2011-05-01

    This report compiles 3-D finite element analyses performed to evaluate the stability of Strategic Petroleum Reserve (SPR) caverns over multiple leach cycles. When oil is withdrawn from a cavern in salt using freshwater, the cavern enlarges. As a result, the pillar separating caverns in the SPR fields is reduced over time due to usage of the reserve. The enlarged cavern diameters and smaller pillars reduce underground stability. Advances in geomechanics modeling enable the allowable pillar to diameter ratio (P/D) to be defined. Prior to such modeling capabilities, the allowable P/D was established as 1.78 based on some very limited experience in other cavern fields. While appropriate for 1980, the ratio conservatively limits the allowable number of oil drawdowns and hence limits the overall utility and life of the SPR cavern field. Analyses from all four cavern fields are evaluated along with operating experience gained over the past 30 years to define a new P/D for the reserve. A new ratio of 1.0 is recommended. This ratio is applicable only to existing SPR caverns.

  9. Abnormal splenic artery diameter/hepatic artery diameter ratio in cirrhosis-induced portal hypertension

    Science.gov (United States)

    Zeng, Dao-Bing; Dai, Chuan-Zhou; Lu, Shi-Chun; He, Ning; Wang, Wei; Li, Hong-Jun

    2013-01-01

    AIM: To determine an optimal cutoff value for abnormal splenic artery diameter/proper hepatic artery diameter (S/P) ratio in cirrhosis-induced portal hypertension. METHODS: Patients with cirrhosis and portal hypertension (n = 770) and healthy volunteers (n = 31) underwent volumetric computed tomography three-dimensional vascular reconstruction to measure the internal diameters of the splenic artery and proper hepatic artery to calculate the S/P ratio. The cutoff value for abnormal S/P ratio was determined using receiver operating characteristic curve analysis, and the prevalence of abnormal S/P ratio and associations between abnormal S/P ratio and major complications of portal hypertension were studied using logistic regression. RESULTS: The receiver operating characteristic analysis showed that the cutoff points for abnormal splenic artery internal diameter and S/P ratio were > 5.19 mm and > 1.40, respectively. The sensitivity, specificity, positive predictive value, and negative predictive value were 74.2%, 45.2%, 97.1%, and 6.6%, respectively. The prevalence of an abnormal S/P ratio in the patients with cirrhosis and portal hypertension was 83.4%. Patients with a higher S/P ratio had a lower risk of developing ascites [odds ratio (OR) = 0.708, 95%CI: 0.508-0.986, P = 0.041] and a higher risk of developing esophageal and gastric varices (OR = 1.483, 95%CI: 1.010-2.175, P = 0.044) and forming collateral circulation (OR = 1.518, 95%CI: 1.033-2.230, P = 0.034). After splenectomy, the portal venous pressure and maximum and mean portal venous flow velocities were reduced, while the flow rate and maximum and minimum flow velocities of the hepatic artery were increased (P portal hypertension, and it can be used as an important marker of splanchnic hemodynamic disturbances. PMID:23483462

  10. Controlling the optical path length in turbid media using differential path-length spectroscopy: fiber diameter dependence

    NARCIS (Netherlands)

    Kaspers, O. P.; Sterenborg, H. J. C. M.; Amelink, A.

    2008-01-01

    We have characterized the path length for the differential path-length spectroscopy (DPS) fiber optic geometry for a wide range of optical properties and for fiber diameters ranging from 200 mu m to 1000 mu m. Phantom measurements show that the path length is nearly constant for scattering

  11. High-resolution computed tomography evaluation of the bronchial lumen to vertebral body diameter and pulmonary artery to vertebral body diameter ratios in anesthetized ventilated normal cats.

    Science.gov (United States)

    Lee-Fowler, Tekla M; Cole, Robert C; Dillon, A Ray; Tillson, D Michael; Garbarino, Rachel; Barney, Sharron

    2017-10-01

    Objectives Bronchial lumen to pulmonary artery diameter (BA) ratio has been utilized to investigate pulmonary pathology on high-resolution CT images. Diseases affecting both the bronchi and pulmonary arteries render the BA ratio less useful. The purpose of the study was to establish bronchial lumen diameter to vertebral body diameter (BV) and pulmonary artery diameter to vertebral body diameter (AV) ratios in normal cats. Methods Using high-resolution CT images, 16 sets of measurements (sixth thoracic vertebral body [mid-body], each lobar bronchi and companion pulmonary artery diameter) were acquired from young adult female cats and 41 sets from pubertal female cats. Results Young adult and pubertal cat BV ratios were not statistically different from each other in any lung lobe. Significant differences between individual lung lobe BV ratios were noted on combined age group analysis. Caudal lung lobe AV ratios were significantly different between young adult and pubertal cats. All other lung lobe AV ratios were not significantly different. Caudal lung lobe AV ratios were significantly different from all other lung lobes but not from each other in both the young adult and pubertal cats. Conclusions and relevance BV ratio reference intervals determined for individual lung lobes could be applied to both young adult and pubertal cats. Separate AV ratios for individual lung lobes would be required for young adult and pubertal cats. These ratios should allow more accurate evaluation of cats with concurrent bronchial and pulmonary arterial disease.

  12. Diameter sensors for tree-length harvesting systems

    Science.gov (United States)

    T.P. McDonald; Robert B. Rummer; T.E. Grift

    2003-01-01

    Most cut-to-length (CTL) harvesters provide sensors for measuring diameter of trees as they are cut and processed. Among other uses, this capability provides a data collection tool for marketing of logs in real time. Logs can be sorted and stacked based on up-to-date market information, then transportation systems optimized to route wood to proper destinations at...

  13. Sex Dimorphism of the Heart Diameters and Cardiothoracic Ratios ...

    African Journals Online (AJOL)

    Objective: To determine gender associated differences in the cardiothoracic ratio (CTR) and heart diameters in a normal Nigerian population. Subject and Method: The normal heart diameters and cardiothoracic ratios were measured from posteroanterior (PA) chest radiographs of healthy 510 male and 508 female ...

  14. Effect of length to thickness ratio on free vibration analysis of thick fiber reinforced plastic skew cross-ply laminate with circular cutout

    Science.gov (United States)

    Srividya, K.; Reddy, Ch. Kishore; Sumanth, Ch. Mohan; Krishnaiah, P. Gopala; Kishan, V. Mallikharjuna

    2018-04-01

    The present investigation deals with the free vibration analysis of a thick four-layered symmetric cross-ply skew laminated composite plate with a circular cutout. Three dimensional finite element models (FEM) which use the elasticity theory for the determination of stiffness matrices are modeled in ANSYS software to evaluate first five natural frequencies of the laminate. The variations of the first five natural frequencies with respect to length to thickness ratio (S) for different diameter to length ratios (d/l) are presented. It is observed that, the natural frequencies decreases with increase of thickness ratio(S).

  15. A computational algorithm addressing how vessel length might depend on vessel diameter

    Science.gov (United States)

    Jing Cai; Shuoxin Zhang; Melvin T. Tyree

    2010-01-01

    The objective of this method paper was to examine a computational algorithm that may reveal how vessel length might depend on vessel diameter within any given stem or species. The computational method requires the assumption that vessels remain approximately constant in diameter over their entire length. When this method is applied to three species or hybrids in the...

  16. Ratio-based lengths of intervals to improve fuzzy time series forecasting.

    Science.gov (United States)

    Huarng, Kunhuang; Yu, Tiffany Hui-Kuang

    2006-04-01

    The objective of this study is to explore ways of determining the useful lengths of intervals in fuzzy time series. It is suggested that ratios, instead of equal lengths of intervals, can more properly represent the intervals among observations. Ratio-based lengths of intervals are, therefore, proposed to improve fuzzy time series forecasting. Algebraic growth data, such as enrollments and the stock index, and exponential growth data, such as inventory demand, are chosen as the forecasting targets, before forecasting based on the various lengths of intervals is performed. Furthermore, sensitivity analyses are also carried out for various percentiles. The ratio-based lengths of intervals are found to outperform the effective lengths of intervals, as well as the arbitrary ones in regard to the different statistical measures. The empirical analysis suggests that the ratio-based lengths of intervals can also be used to improve fuzzy time series forecasting.

  17. Sample preparation and scanning protocol for computerised analysis of root length and diameter

    NARCIS (Netherlands)

    Bouma, T.J.; Nielsen, K.F.; Koutstaal, B.P.

    2000-01-01

    Root length and diameter distribution are important characteristics to be considered when describing and comparing root systems. Root length and root-diameter distribution may be obtained in two ways: by microscopical measurements, which are laborious, or by computerised analysis, which is fast but

  18. Influence of core diameter and length of polymer optical fiber on Brillouin scattering properties

    Science.gov (United States)

    Mizuno, Yosuke; Ishigure, Takaaki; Nakamura, Kentaro

    2012-02-01

    Brillouin scattering in perfluorinated graded-index polymer optical fibers (PFGI-POFs) is potentially useful in developing high-accuracy distributed temperature sensors with reduced strain sensitivity. In this study, we investigate, both experimentally and theoretically, the influence of the fiber core diameter and length on the Brillouin gain spectra (BGS) in PFGI-POFs. First, we show that smaller core diameter drastically enhances the Stokes power using PFGI-POFs with 62.5-μm and 120-μm core diameters, and discuss the Brillouin threshold power. Then, we demonstrate that the PFGI-POF length has little influence on the BGS when the length is longer than 50 m. We also predict that, at 1.55-μm wavelength, it is difficult to reduce the Brillouin threshold power of PFGI-POFs below that of long silica single-mode fibers even if their core diameter is sufficiently reduced to satisfy the single-mode condition. Finally, making use of the enhanced Stokes signal, we confirm the Brillouin linewidth narrowing effect.

  19. Distal Ureteral Diameter Ratio is Predictive of Breakthrough Febrile Urinary Tract Infection.

    Science.gov (United States)

    Arlen, Angela M; Leong, Traci; Guidos, P Joseph; Alexander, Siobhan E; Cooper, Christopher S

    2017-12-01

    Distal ureteral diameter ratio is an objective measure that is prognostic of spontaneous resolution of vesicoureteral reflux. Along with likelihood of resolution, improved identification of children at risk for recurrent febrile urinary tract infections may impact management decisions. We evaluated the usefulness of ureteral diameter ratio as a predictive factor for breakthrough febrile urinary tract infections. Children with primary vesicoureteral reflux and detailed voiding cystourethrogram were identified. Ureteral diameter ratio was computed by measuring largest ureteral diameter within the pelvis and dividing by the distance between L1 and L3 vertebral bodies. Demographics, vesicoureteral reflux grade, laterality, presence/absence of bladder-bowel dysfunction, and ureteral diameter ratio were tested in univariate and multivariable analyses. Primary outcome was breakthrough febrile urinary tract infections. We analyzed 112 girls and 28 boys with a mean ± SD age of 2.5 ± 2.3 years at diagnosis. Vesicoureteral reflux was grade 1 to 2 in 64 patients (45.7%), grade 3 in 50 (35.7%), grade 4 in 16 (11.4%) and grade 5 in 10 (7.2%). Mean ± SD followup was 3.2 ± 2.7 years. A total of 40 children (28.6%) experienced breakthrough febrile urinary tract infections. Ureteral diameter ratio was significantly greater in children with (0.36) vs without (0.25) breakthrough febrile infections (p = 0.004). Controlling for vesicoureteral reflux grade, every 0.1 U increase in ureteral diameter ratio resulted in 1.7 times increased odds of breakthrough infection (95% CI 1.24 to 2.26, p urinary tract infections independent of reflux grade. Ureteral diameter ratio provides valuable prognostic information about risk of recurrent pyelonephritis and may assist with clinical decision-making. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  20. Experimental tests of the effect of rotor diameter ratio and blade number to the cross-flow wind turbine performance

    Science.gov (United States)

    Susanto, Sandi; Tjahjana, Dominicus Danardono Dwi Prija; Santoso, Budi

    2018-02-01

    Cross-flow wind turbine is one of the alternative energy harvester for low wind speeds area. Several factors that influence the power coefficient of cross-flow wind turbine are the diameter ratio of blades and the number of blades. The aim of this study is to find out the influence of the number of blades and the diameter ratio on the performance of cross-flow wind turbine and to find out the best configuration between number of blades and diameter ratio of the turbine. The experimental test were conducted under several variation including diameter ratio between outer and inner diameter of the turbine and number of blades. The variation of turbine diameter ratio between inner and outer diameter consisted of 0.58, 0.63, 0.68 and 0.73 while the variations of the number of blades used was 16, 20 and 24. The experimental test were conducted under certain wind speed which are 3m/s until 4 m/s. The result showed that the configurations between 0.68 diameter ratio and 20 blade numbers is the best configurations that has power coefficient of 0.049 and moment coefficient of 0.185.

  1. Effect of length and diameter of fiber reinforced composite post (FRC on fracture resistance of remaining tooth structure

    Directory of Open Access Journals (Sweden)

    Mahdiyeh seifi

    2013-03-01

    Full Text Available Introduction: Post and core has been considered for endodontically treated tooth, especially in cases with severe damage crowns. Recently fiber reinforced composite posts (FRC post have been used in the treatment of endodontically treated teeth. Because the length and diameter of posts are effective in stress distribution, the purpose of this study is to evaluate the effect of length and diameter of FRC post on fracture resistance. Methods: In this experimental study, 36 glass fiber posts with combination of 7mm, 9mm, and 12mm length and 1.1mm, 1.3mm and 1.5mm diameter were divided into 9 groups of 4. These posts were cemented in root canals by Panavia. Samples were tested with 45° compressive forces for the evaluation of fracture resistance. Datas were analyzed using SPSS soft ware and One- way and Two-way ANOVA analyses. Results: Fracture resistance did not increase significantly with the effect of length and diameter simultaneously (P=0.85. Samples with 12mm length and 1.5mm diameter had the greatest fracture resistance (1023/33N±239/22. The minimum fracture resistance had occurred in post with 7mm length and 1.5mm diameter (503/13N ±69/18. Fracture resistance increased significantly by increasing the length and the same diameter. Conclusion: It can be concluded that fracture resistance is affected by the length and not the diameter of FRC post.

  2. Numerical Investigation of Liquid Carryover in T-Junction with Different Diameter Ratios

    Science.gov (United States)

    Pao, William; Sam, Ban; Saieed, Ahmed; Tran, Cong Minh

    2018-03-01

    In offshore Malaysia, T-junction is installed at the production header as a compact separator to tap produced gas from reservoir as fuel gas for power generation. However, excessive liquid carryover in T-junction presents a serious operational issue because it trips the whole production platform. The primary objective of present study is to numerically investigate the liquid carryover due to formation of slug, subsequently its liquid carryover at different diameter ratio. The analyses were carried out on a model with 0.0254 m (1 inch) diameter horizontal main arm and a vertically upward side arm using Volume of Fluid Method. Three different sides to main arm diameter ratio of 1.0, 0.5 and 0.3 were investigated with different gas and liquid superficial velocities. The results showed that, while the general trend is true that smaller diameter ratio T-junction has lesser liquid take off capacity, it has a very high frequency of low liquid carryover threshold. In other words, under slug flow, smaller diameter ratio T-junction is constantly transporting liquid even though at a lesser volume in comparison to regular T-junction.

  3. The dependence of the optoelectrical properties of silver nanowire networks on nanowire length and diameter

    International Nuclear Information System (INIS)

    Sorel, Sophie; Lyons, Philip E; De, Sukanta; Coleman, Jonathan N; Dickerson, Janet C

    2012-01-01

    We have characterized the optoelectrical properties of networks of silver nanowires as a function of nanowire dimension by measuring transmittance (T) and sheet resistance (R s ) for a large number of networks of different thicknesses fabricated from wires of different diameters (D) and lengths (L). We have analysed these data using both bulk-like and percolative models. We find the network DC conductivity to scale linearly with wire length while the optical conductivity is approximately invariant with nanowire length. The ratio of DC to optical conductivity, often taken as a figure of merit for transparent conductors, scales approximately as L/D. Interestingly, the percolative exponent, n, scales empirically as D 2 , while the percolative figure of merit, Π, displays large values at low D. As high T and low R s are associated with low n and high Π, these data are consistent with improved optoelectrical performance for networks of low-D wires. We predict that networks of wires with D = 25 nm could give sheet resistance as low as 25 Ω/□ for T = 90%. (paper)

  4. Can ratio of the biggest tumor diameter to total tumor diameter be a new parameter in the differential diagnosis of agressive and favorable multifocal papillary thyroid microcarcinoma?

    Science.gov (United States)

    Tam, Abbas Ali; Özdemir, Didem; Çuhacı, Neslihan; Başer, Hüsniye; Dirikoç, Ahmet; Aydın, Cevdet; Yazgan, Aylin Kılıç; Ersoy, Reyhan; Çakır, Bekir

    2017-02-01

    In this study, we aimed to evaluate the usefulness of a new parameter -ratio of the biggest tumor diameter to total tumor diameter- for the differentiation of agressive and favorable papillary thyroid microcarcinomas (PTMC). The diameter of the biggest tumor focus was taken as the primary tumor diameter. Total tumor diameter was calculated as the sum of the maximal diameter of each lesion. Ratio of primary tumor diameter to total tumor diameter was defined as tumor diameter ratio (TDR). Positive and negative predictive value, sensitivity and specificity of TDR to predict capsular invasion, extrathyroidal extension (ETE) and lymph node metastasis (LNM) were determined. Mean TDR was significantly lower in multifocal PTMC patients with capsular invasion, ETE, lymphovascular invasion and LNM compared to patients without these features. The sensitivities of TDR for the detection of LNM, ETE and capsular invasion were 100%, 100% and 94.2%, respectively. Specificity of TDR was 86.2% for LNM, 88% for ETE and 94.7% for capsular invasion. Best cut off values of TDR that can predict capsular invasion, ETE and LNM in multifocal PTMC were 0.62, 0.57 and 0.56, respectively. Multifocal papillary thyroid carcinoma patients with capsular invasion, ETE and LNM had significantly lower mean TDR when compared to ones without these features. Decreased TDR was associated with capsular invasion, ETE and LNM in patients with multifocal PTMC and PTC. This new parameter might be particularly helpful for the detection of aggressive behavior in multifocal PTMCs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Polyol Synthesis of Silver Nanowires by Heterogeneous Nucleation and Mechanistic Aspects Influencing its Length and Diameter

    Science.gov (United States)

    Schuette, Waynie Mark

    Various additives are employed in the polyol synthesis of silver nanowires (Ag NWs), which are typically halide salts such as NaCl. A variety of mechanistic roles have been suggested for these additives. My research showed that the early addition of NaCl in the polyol synthesis of Ag NWs from AgNO3 in ethylene glycol results in the rapid formation of AgCl nanocubes, which induce the heterogeneous nucleation of metallic Ag upon their surfaces. Ag NWs subsequently grow from these nucleation sites. The conclusions are supported by studies using ex-situ generated AgCl nanocubes. Additionally, the final mean silver nanowire diameter is found to be independent of the size of the heterogeneous nucleant, showing that the diameter is not significantly influenced by the nucleation event. Kinetics studies determine that nanowire diameter, length, and aspect ratio grow in parallel to one another and with the extent of the Ag+ reduction reaction, demonstrating that growth is reduction-rate limited. The results are interpreted to support nanowire growth by a surface-catalyzed reduction process occurring on all nanowire surfaces, and to exclude nanoparticle aggregation or Ostwald ripening as primary components of the growth mechanism.

  6. Nano-scaled graphene platelets with a high length-to-width aspect ratio

    Science.gov (United States)

    Zhamu, Aruna; Guo, Jiusheng; Jang, Bor Z.

    2010-09-07

    This invention provides a nano-scaled graphene platelet (NGP) having a thickness no greater than 100 nm and a length-to-width ratio no less than 3 (preferably greater than 10). The NGP with a high length-to-width ratio can be prepared by using a method comprising (a) intercalating a carbon fiber or graphite fiber with an intercalate to form an intercalated fiber; (b) exfoliating the intercalated fiber to obtain an exfoliated fiber comprising graphene sheets or flakes; and (c) separating the graphene sheets or flakes to obtain nano-scaled graphene platelets. The invention also provides a nanocomposite material comprising an NGP with a high length-to-width ratio. Such a nanocomposite can become electrically conductive with a small weight fraction of NGPs. Conductive composites are particularly useful for shielding of sensitive electronic equipment against electromagnetic interference (EMI) or radio frequency interference (RFI), and for electrostatic charge dissipation.

  7. Optimization of the Critical Diameter and Average Path Length of Social Networks

    Directory of Open Access Journals (Sweden)

    Haifeng Du

    2017-01-01

    Full Text Available Optimizing average path length (APL by adding shortcut edges has been widely discussed in connection with social networks, but the relationship between network diameter and APL is generally ignored in the dynamic optimization of APL. In this paper, we analyze this relationship and transform the problem of optimizing APL into the problem of decreasing diameter to 2. We propose a mathematic model based on a memetic algorithm. Experimental results show that our algorithm can efficiently solve this problem as well as optimize APL.

  8. Analysis of the horizontal corneal diameter, central corneal thickness, and axial length in premature infants

    Directory of Open Access Journals (Sweden)

    Ozdemir Ozdemir

    2014-08-01

    Full Text Available Purpose: To determine the horizontal corneal diameter, central corneal thickness, and axial length in premature infants. Methods: Infants with a birth weight of less than 2,500 g or with a gestation period of less than 36 weeks were included in the study. Infants with retinopathy of prematurity (ROP were allocated to Group 1 (n=138, while those without ROP were allocated to Group 2 (n=236. All infants underwent a complete ophthalmologic examination, including corneal diameter measurements, pachymetry, biometry, and fundoscopy. Between-group comparisons of horizontal corneal diameter, central corneal thickness, and axial lengths were performed. Independent sample t-tests were used for statistical analysis. Results: Data was obtained from 374 eyes of 187 infants (102 female, 85 male. The mean gestational age at birth was 30.7 ± 2.7 weeks (range 25-36 weeks, the mean birth weight was 1,514 ± 533.3 g (range 750-1,970 g, and the mean postmenstrual age at examination was 40.0 ± 4.8 weeks. The mean gestational age and the mean birth weight of Group 1 were statistically lower than Group 2 (p0.05. Conclusions: The presence of ROP in premature infants does not alter the horizontal corneal diameter, central corneal thickness, or axial length.

  9. Quantitative Classification of Rice (Oryza sativa L.) Root Length and Diameter Using Image Analysis.

    Science.gov (United States)

    Gu, Dongxiang; Zhen, Fengxian; Hannaway, David B; Zhu, Yan; Liu, Leilei; Cao, Weixing; Tang, Liang

    2017-01-01

    Quantitative study of root morphological characteristics of plants is helpful for understanding the relationships between their morphology and function. However, few studies and little detailed and accurate information of root characteristics were reported in fine-rooted plants like rice (Oryza sativa L.). The aims of this study were to quantitatively classify fine lateral roots (FLRs), thick lateral roots (TLRs), and nodal roots (NRs) and analyze their dynamics of mean diameter (MD), lengths and surface area percentage with growth stages in rice plant. Pot experiments were carried out during three years with three rice cultivars, three nitrogen (N) rates and three water regimes. In cultivar experiment, among the three cultivars, root length of 'Yangdao 6' was longest, while the MD of its FLR was the smallest, and the mean diameters for TLR and NR were the largest, the surface area percentage (SAP) of TLRs (SAPT) was the highest, indicating that Yangdao 6 has better nitrogen and water uptake ability. High N rate increased the length of different types of roots and increased the MD of lateral roots, decreased the SAP of FLRs (SAPF) and TLRs, but increased the SAP of NRs (SAPN). Moderate decrease of water supply increased root length and diameter, water stress increased the SAPF and SAPT, but decreased SAPN. The quantitative results indicate that rice plant tends to increase lateral roots to get more surface area for nitrogen and water uptake when available assimilates are limiting under nitrogen and water stress environments.

  10. Quantitative Classification of Rice (Oryza sativa L.) Root Length and Diameter Using Image Analysis

    Science.gov (United States)

    Gu, Dongxiang; Zhen, Fengxian; Hannaway, David B.; Zhu, Yan; Liu, Leilei; Cao, Weixing; Tang, Liang

    2017-01-01

    Quantitative study of root morphological characteristics of plants is helpful for understanding the relationships between their morphology and function. However, few studies and little detailed and accurate information of root characteristics were reported in fine-rooted plants like rice (Oryza sativa L.). The aims of this study were to quantitatively classify fine lateral roots (FLRs), thick lateral roots (TLRs), and nodal roots (NRs) and analyze their dynamics of mean diameter (MD), lengths and surface area percentage with growth stages in rice plant. Pot experiments were carried out during three years with three rice cultivars, three nitrogen (N) rates and three water regimes. In cultivar experiment, among the three cultivars, root length of ‘Yangdao 6’ was longest, while the MD of its FLR was the smallest, and the mean diameters for TLR and NR were the largest, the surface area percentage (SAP) of TLRs (SAPT) was the highest, indicating that Yangdao 6 has better nitrogen and water uptake ability. High N rate increased the length of different types of roots and increased the MD of lateral roots, decreased the SAP of FLRs (SAPF) and TLRs, but increased the SAP of NRs (SAPN). Moderate decrease of water supply increased root length and diameter, water stress increased the SAPF and SAPT, but decreased SAPN. The quantitative results indicate that rice plant tends to increase lateral roots to get more surface area for nitrogen and water uptake when available assimilates are limiting under nitrogen and water stress environments. PMID:28103264

  11. Usefulness of meniscal width to transverse diameter ratio on coronal MRI in the diagnosis of incomplete discoid lateral meniscus

    International Nuclear Information System (INIS)

    Park, H.J.; Lee, S.Y.; Park, N.-H.; Chung, E.C.; Park, J.Y.; Kim, M.S.; Lee, E.J.

    2014-01-01

    Aim: To evaluate the clinical utility of the meniscal width to transverse diameter ratio (L/M ratio) of the lateral meniscus in the diagnosis of incomplete discoid lateral meniscus (IDLM) as compared with the arthroscopic diagnosis, meniscal width to tibial diameter ratio (L/T ratio) and conventional lateral meniscus width criteria. Materials and methods: This retrospective study sample included 41 patients with IDLM who underwent knee magnetic resonance imaging (MRI) and arthroscopy, as well as 50 controls with normal lateral menisci. MRI examinations were interpreted independently by two radiologists, both of whom were blinded to clinical information and radiological reports. Assessment of meniscal width (L), maximal transverse diameter of the lateral meniscus (M), and transverse diameter of the tibia (T) was carried out on central coronal sections that were observed to pass through the medial collateral ligament. L/M and L/T ratios were calculated. These results were correlated with arthroscopic findings and analysed statistically using categorical regression analysis and non-parametric correlation analysis. Using arthroscopic findings as the standard of reference, sensitivity and specificity were calculated for: (1) 12, 13, 14, and 15 mm meniscal width thresholds; (2) 40%, 50%, 60%, and 70% L/M ratio thresholds; and (3) 15%, 18%, 20%, and 25% L/T ratio thresholds. Results: The mean L/M ratio of the IDLM was approximately 67% and was statistically significantly higher than the control (44%). The best diagnostic discrimination was achieved using a threshold of 50%. The mean L/T ratio of the IDLM was approximately 23% and was statistically significant. The best diagnostic discrimination was achieved using a threshold of 18%. The threshold of 13 mm of meniscal width also showed high sensitivity and high specificity. Conclusion: The use of the L/M ratio or L/T ratio in combination with meniscal width criteria may be a useful method for evaluating IDLM

  12. Effect of Length, Diameter, Chirality, Deformation, and Strain on Contact Thermal Conductance between Single Wall Carbon Nanotubes

    Science.gov (United States)

    Varshney, Vikas; Lee, Jonghoon; Brown, Joshua S.; Farmer, Barry L.; Voevodin, Andrey A.; Roy, Ajit K.

    2018-04-01

    Thermal energy transfer across physically interacting single-wall carbon nanotube (SWCNT) interconnects has been investigated using non-equilibrium molecular dynamics simulations. The role of various geometrical and structural (length, diameter, chirality) as well as external (deformation and strain) carbon nanotube (CNT) parameters has been explored to estimate total as well as area-normalized thermal conductance across cross-contact interconnects. It is shown that the CNT aspect ratio and degree of lateral as well as tensile deformation play a significant role in determining the extent of thermal energy exchange across CNT contacts, while CNT chirality has a negligible influence on thermal transport. Depending on the CNT diameter, aspect ratio, and degree of deformation at the contact interface, the thermal conductance values can vary significantly –by more than an order of magnitude for total conductance and a factor of 3 to 4 for area-normalized conductance. The observed trends are discussed from the perspective of modulation in number of low frequency out-of-plane (transverse, flexural, and radial) phonons that transmit thermal energy across the contact and govern the conductance across the interface. The established general dependencies for phonon governed thermal transport at CNT contacts are anticipated to help design and performance prediction of CNT-based flexible nanoelectronic devices, where CNT-CNT contact deformation and strain are routinely encountered during device operations.

  13. 内外径比值对横向效应侵彻体的影响分析%Simulation Analysis of the Influence of Length-Diameter Ratio on Lateral Effect

    Institute of Scientific and Technical Information of China (English)

    焦志刚; 曹旭; 张明博

    2017-01-01

    通过研究不同内外径比值对PELE横向效应的影响,对不同内外径比情况弹丸侵彻靶板的过程进行数值仿真.结果表明:任意一种类型横向效应侵彻体,其消耗的能量随着内外径比值的增大而增大;对于一个设定的内外径比,总有一个最佳长径比值使其横向效应效果最优.%Through the study of the influence of different ratio of inner and outer diameters on the transverse effect of PELE,numerical simulation of projectile penetration into target plate with different ratio of internal and external diameter was carried out.The results show that:for any type of lateral effect penetrator,its energy consumption increases as the diameter ratio increases;for a set diameter ratio,there is always an optimum value so that the lateral effect will be best.

  14. CT dose equilibration and energy absorption in polyethylene cylinders with diameters from 6 to 55 cm

    International Nuclear Information System (INIS)

    Li, Xinhua; Zhang, Da; Liu, Bob

    2015-01-01

    Purpose: ICRU Report No. 87 Committee and AAPM Task Group 200 designed a three-sectional polyethylene phantom of 30 cm in diameter and 60 cm in length for evaluating the midpoint dose D L (0) and its rise-to-the-equilibrium curve H(L) = D L (0)/D eq from computed tomography (CT) scanning, where D eq is the equilibrium dose. To aid the use of the phantom in radiation dose assessment and to gain an understanding of dose equilibration and energy absorption in polyethylene, the authors evaluated the short (20 cm) to long (60 cm) phantom dose ratio with a polyethylene diameter of 30 cm, assessed H(L) in polyethylene cylinders of 6–55 cm in diameters, and examined energy absorption in these cylinders. Methods: A GEANT4-based Monte Carlo program was used to simulate the single axial scans of polyethylene cylinders (diameters 6–55 cm and length 90 cm, as well as diameter 30 cm and lengths 20 and 60 cm) on a clinical CT scanner (Somatom Definition dual source CT, Siemens Healthcare). Axial dose distributions were computed on the phantom central and peripheral axes. An average dose over the central 23 or 100 mm region was evaluated for modeling dose measurement using a 0.6 cm 3 thimble chamber or a 10 cm long pencil ion chamber, respectively. The short (20 cm) to long (90 cm) phantom dose ratios were calculated for the 30 cm diameter polyethylene phantoms scanned at four tube voltages (80–140 kV) and a range of beam apertures (1–25 cm). H(L) was evaluated using the dose integrals computed with the 90 cm long phantoms. The resultant H(L) data were subsequently used to compute the fraction of the total energy absorbed inside or outside the scan range (E in /E or E out /E) on the phantom central and peripheral axes, where E = LD eq was the total energy absorbed along the z axis. Results: The midpoint dose in the 60 cm long polyethylene phantom was equal to that in the 90 cm long polyethylene phantom. The short-to-long phantom dose ratios changed with beam aperture and

  15. CT dose equilibration and energy absorption in polyethylene cylinders with diameters from 6 to 55 cm

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xinhua; Zhang, Da; Liu, Bob, E-mail: bliu7@mgh.harvard.edu [Division of Diagnostic Imaging Physics and Webster Center for Advanced Research and Education in Radiation, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts 02114 (United States)

    2015-06-15

    Purpose: ICRU Report No. 87 Committee and AAPM Task Group 200 designed a three-sectional polyethylene phantom of 30 cm in diameter and 60 cm in length for evaluating the midpoint dose D{sub L}(0) and its rise-to-the-equilibrium curve H(L) = D{sub L}(0)/D{sub eq} from computed tomography (CT) scanning, where D{sub eq} is the equilibrium dose. To aid the use of the phantom in radiation dose assessment and to gain an understanding of dose equilibration and energy absorption in polyethylene, the authors evaluated the short (20 cm) to long (60 cm) phantom dose ratio with a polyethylene diameter of 30 cm, assessed H(L) in polyethylene cylinders of 6–55 cm in diameters, and examined energy absorption in these cylinders. Methods: A GEANT4-based Monte Carlo program was used to simulate the single axial scans of polyethylene cylinders (diameters 6–55 cm and length 90 cm, as well as diameter 30 cm and lengths 20 and 60 cm) on a clinical CT scanner (Somatom Definition dual source CT, Siemens Healthcare). Axial dose distributions were computed on the phantom central and peripheral axes. An average dose over the central 23 or 100 mm region was evaluated for modeling dose measurement using a 0.6 cm{sup 3} thimble chamber or a 10 cm long pencil ion chamber, respectively. The short (20 cm) to long (90 cm) phantom dose ratios were calculated for the 30 cm diameter polyethylene phantoms scanned at four tube voltages (80–140 kV) and a range of beam apertures (1–25 cm). H(L) was evaluated using the dose integrals computed with the 90 cm long phantoms. The resultant H(L) data were subsequently used to compute the fraction of the total energy absorbed inside or outside the scan range (E{sub in}/E or E{sub out}/E) on the phantom central and peripheral axes, where E = LD{sub eq} was the total energy absorbed along the z axis. Results: The midpoint dose in the 60 cm long polyethylene phantom was equal to that in the 90 cm long polyethylene phantom. The short-to-long phantom dose

  16. Numerical simulation of two-phase slug flow with liquid carryover in different diameter ratio T-junction

    Science.gov (United States)

    Pao, W.; Hon, L.; Saieed, A.; Ban, S.

    2017-10-01

    A smaller diameter conduit pointing at 12 o’clock position is typically hot-tapped to a horizontal laying production header in offshore platform to tap produced gas for downstream process train. This geometric feature is commonly known as T-junction. The nature of multiphase fluid splitting at the T-junction is a major operational challenge due to unpredictable production environment. Often, excessive liquid carryover occurs in the T-junction, leading to complete platform trip and halt production. This is because the downstream process train is not designed to handle excessive liquid. The objective of this research is to quantify the effect of different diameter ratio on phase separation efficiency in T-junction. The liquid carryover is modelled as two-phase air-water flow using Eulerian Mixture Model coupled with Volume of Fluid Method to mimic the slug flow in the main pipe. The focus in this paper is 0.0254 m (1 inch) diameter horizontal main arm and vertical branch arm with diameter ratio of 1.0, 0.5 and 0.3. The present research narrowed the investigation to only slug flow regime using Baker’s map as reference. The investigation found that, contrary to common believe, smaller diameter ratio T-junction perform worse than larger diameter ratio T-junction.

  17. Influence of pellet diameter and length on the quality of pellets and performance, nutrient utilisation and digestive tract development of broilers fed on wheat-based diets.

    Science.gov (United States)

    Abdollahi, M R; Ravindran, V; Wester, T J; Ravindran, G; Thomas, D V

    2013-06-01

    1. The influence of pellet diameter and length on the quality of pellets and performance, nutrient utilisation and digestive tract development of broilers given wheat-based diets was examined from 10 to 42 d of age. The experimental design was a 2 × 2 factorial arrangement of treatments evaluating two pellet diameters (3 and 4.76 mm) and two pellet lengths (3 and 6 mm). From 0 to 9 d of age, all birds were offered a common starter diet pelleted with a 3-mm diameter die and 3-mm length. Broiler grower (d 10 to 21) and finisher (d 22 to 42) diets, based on wheat, were formulated and then subjected to the 4 different treatments. 2. In grower diets, increasing pellet diameter and pellet length reduced the gelatinised starch (GS) content of the diets. In finisher diets, GS content of 3-mm diameter pellets did not change with increasing pellet length but decreased in 4.76-mm diameter pellets. 3. In grower and finisher diets, increments in intact pellet weight, pellet durability index and pellet hardness with increasing pellet length were greater in 3-mm diameter pellets than those with 4.76-mm diameter. 4. Increasing pellet length from 3 to 6 mm increased apparent metabolisable energy values. Neither the interaction nor main effects were significant for the ileal digestibility of nitrogen and starch. 5. During the grower period (d 10 to 21), birds given pellets of 6-mm length had greater body-weight gain than those given 3-mm length pellets. Feeding 6-mm length pellets decreased feed per body-weight gain compared to 3-mm length pellets. During the finisher (d 22 to 42) and whole grow-out (d 10 to 42) periods, while different pellet lengths had no effect on feed per body-weight gain values at 3-mm pellet diameter, increasing the pellet length decreased feed per body-weight gain at 4.76-mm pellet diameter. 6. Increasing pellet diameter and pellet length reduced the relative length of duodenum. Birds given 3-mm diameter pellets had heavier proventriculus compared to

  18. Normative data for uterine size according to age and gravidity and possible role of the classical golden ratio.

    Science.gov (United States)

    Verguts, J; Ameye, L; Bourne, T; Timmerman, D

    2013-12-01

    To document normal measurements (length, width, anteroposterior (AP) diameter) and proportions of the non-pregnant uterus according to age and gravidity. We hypothesized that uterine proportions conform to the classical 'golden ratio' (1.618). This was a retrospective study of ultrasonographic measurements of the length, width and AP diameter of non-pregnant uteri recorded in our database between 1 January 2000 and 31 July 2012. All patients for whom abnormal findings were reported were excluded and only the first set of measurements for each patient was retained for analysis. Loess (local regression) analysis was performed using age and gravidity as explanatory variables. Measurements of 5466 non-pregnant uteri were retrieved for analysis. The mean length was found to increase to 72 mm at the age of 40 and decrease to 42 mm at the age of 80 years. Gravidity was associated with greater uterine length, width and AP diameter. Mean length/width ratio was found to be 1.857 at birth, decreasing to 1.452 at the age of 91 years. At the age of 21 years, the mean ratio was found to be 1.618, i.e. equal to the golden ratio. Increasing gravidity was associated with lower mean length/width ratio. Uterine size in non-pregnant women varies in relation to age and gravidity. Mean length/width ratio conformed to the golden ratio at the age of 21, coinciding with peak fertility. Copyright © 2013 ISUOG. Published by John Wiley & Sons Ltd.

  19. Development of the heated length to diameter correction factor on critical heat flux using the artificial neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Ho; Baek, Won Pil; Chang, Soon Heung [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of); Chun, Tae Hyun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1999-12-31

    With using artificial neural networks (ANNs), an analytical study related to the heated length effect on critical heat flux (CHF) has been carried out to make an improvement of the CHF prediction accuracy based on local condition correlations or table. It has been carried out to suggest a feasible criterion of the threshold length-to-diameter (L/D) value in which heated length could affect CHF. And within the criterion, a L/D correction factor has been developed through conventional regression. In order to validate the developed L/D correction factor, CHF experiments for various heated lengths have been carried out under low and intermediate pressure conditions. The developed threshold L/D correlation provides a new feasible criterion of L/D threshold value. The developed correction factor gives a reasonable accuracy for the original database, showing the error of -2.18% for average and 27.75% for RMS, and promising results for new experimental data. 7 refs., 12 figs., 1 tab. (Author)

  20. Development of the heated length to diameter correction factor on critical heat flux using the artificial neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Ho; Baek, Won Pil; Chang, Soon Heung [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of); Chun, Tae Hyun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1998-12-31

    With using artificial neural networks (ANNs), an analytical study related to the heated length effect on critical heat flux (CHF) has been carried out to make an improvement of the CHF prediction accuracy based on local condition correlations or table. It has been carried out to suggest a feasible criterion of the threshold length-to-diameter (L/D) value in which heated length could affect CHF. And within the criterion, a L/D correction factor has been developed through conventional regression. In order to validate the developed L/D correction factor, CHF experiments for various heated lengths have been carried out under low and intermediate pressure conditions. The developed threshold L/D correlation provides a new feasible criterion of L/D threshold value. The developed correction factor gives a reasonable accuracy for the original database, showing the error of -2.18% for average and 27.75% for RMS, and promising results for new experimental data. 7 refs., 12 figs., 1 tab. (Author)

  1. Factors associated with changes in vaginal length and diameter during pelvic radiotherapy for cervical cancer.

    Science.gov (United States)

    Martins, Jumara; Vaz, Ana Francisca; Grion, Regina Celia; Esteves, Sérgio Carlos Barros; Costa-Paiva, Lúcia; Baccaro, Luiz Francisco

    2017-12-01

    This study reports the incidence and factors associated with vaginal stenosis and changes in vaginal dimensions after pelvic radiotherapy for cervical cancer. A descriptive longitudinal study with 139 women with cervical cancer was conducted from January 2013 to November 2015. The outcome variables were vaginal stenosis assessed using the Common Terminology Criteria for Adverse Events (CTCAE v3.0) and changes in vaginal diameter and length after the end of radiotherapy. Independent variables were the characteristics of the neoplasm, clinical and sociodemographic data. Bivariate analysis was carried out using χ 2 , Kruskal-Wallis and Mann-Whitney's test. Multiple analysis was carried out using Poisson regression and a generalized linear model. Most women (50.4%) had stage IIIB tumors. According to CTCAE v3.0 scale, 30.2% had no stenosis, 69.1% had grade 1 and 0.7% had grade 2 stenosis after radiotherapy. Regarding changes in vaginal measures, the mean variation in diameter was - 0.6 (± 1.7) mm and the mean variation in length was - 0.6 (± 1.3) cm. In the final statistical model, having tumoral invasion of the vaginal walls (coefficient + 0.73, p vaginal stenosis and lower reduction of vaginal dimensions. Advanced clinical stage (coefficient + 1.44; p = 0.02) and receiving brachytherapy/teletherapy (coefficient - 1.17, p vaginal dimensions. Most women had mild vaginal stenosis with slight reductions in both diameter and length of the vaginal canal. Women with tumoral invasion of the vagina have an increase in vaginal length soon after radiotherapy due to a reduction in tumoral volume.

  2. Estimating the hemodynamic influence of variable main body-to-iliac limb length ratios in aortic endografts.

    Science.gov (United States)

    Georgakarakos, Efstratios; Xenakis, Antonios; Georgiadis, George S

    2018-02-01

    We conducted a computational study to assess the hemodynamic impact of variant main body-to-iliac limb length (L1/L2) ratios on certain hemodynamic parameters acting on the endograft (EG) either on the normal bifurcated (Bif) or the cross-limb (Cx) fashion. A customary bifurcated 3D model was computationally created and meshed using the commercially available ANSYS ICEM (Ansys Inc., Canonsburg, PA, USA) software. The total length of the EG, was kept constant, while the L1/L2 ratio ranged from 0.3 to 1.5 in the Bif and Cx reconstructed EG models. The compliance of the graft was modeled using a Fluid Structure Interaction method. Important hemodynamic parameters such as pressure drop along EG, wall shear stress (WSS) and helicity were calculated. The greatest pressure decrease across EG was calculated in the peak systolic phase. With increasing L1/L2 it was found that the Pressure Drop was increasing for the Cx configuration, while decreasing for the Bif. The greatest helicity (4.1 m/s2) was seen in peak systole of Cx with ratio of 1.5 whereas its greatest value (2 m/s2) was met in peak systole in the Bif with the shortest L1/L2 ratio (0.3). Similarly, the maximum WSS value was highest (2.74Pa) in the peak systole for the 1.5 L1/L2 of the Cx configuration, while the maximum WSS value equaled 2 Pa for all length ratios of the Bif modification (with the WSS found for L1/L2=0.3 being marginally higher). There was greater discrepancy in the WSS values for all L1/L2 ratios of the Cx bifurcation compared to Bif. Different L1/L2 rations are shown to have an impact on the pressure distribution along the entire EG while the length ratio predisposing to highest helicity or WSS values is also determined by the iliac limbs pattern of the EG. Since current custom-made EG solutions can reproduce variability in main-body/iliac limbs length ratios, further computational as well as clinical research is warranted to delineate and predict the hemodynamic and clinical effect of variable

  3. Polyethylene Glycol (PEG-Treated Hydroponic Culture Reduces Length and Diameter of Root Hairs of Wheat Varieties

    Directory of Open Access Journals (Sweden)

    Arif Hasan Khan Robin

    2015-10-01

    Full Text Available Wheat is an important cereal crop worldwide that often suffers from moisture deficits at the reproductive stage. Polyethylene glycol (PEG-treated hydroponic conditions create negative osmotic potential which is compared with moisture deficit stress. An experiment was conducted in a growth chamber to study the effects of PEG on root hair morphology and associated traits of wheat varieties. Plants of 13 wheat varieties were grown hydroponically and three different doses of PEG 6000 (w/v: 0% (control, 0.3% and 0.6% (less than −1 bar were imposed on 60 days after sowing for 20 days’ duration. A low PEG concentration was imposed to observe how initial low moisture stress might affect root hair development. PEG-treated hydroponic culture significantly decreased root hair diameter and length. Estimated surface area reduction of root hairs at the main axes of wheat plants was around nine times at the 0.6% PEG level compared to the control plants. Decrease in root hair diameter and length under PEG-induced culture decreased “potential” root surface area per unit length of main root axis. A negative association between panicle traits, length and dry weight and the main axis length of young roots indicated competition for carbon during their development. Data provides insight into how a low PEG level might alter root hair development.

  4. Ratio of sheath thickness to Debye length for a slightly ionized continuum plasma

    International Nuclear Information System (INIS)

    Hamilton, J.

    1980-01-01

    The penetration of plasma sheaths for spherical probes in a slightly ionized continuum plasma has been computed for values of epsilon (the ratio of ion to electron temperature) of 0.01 and 1.0 with rhosub(p) (the ratio of probe radius to plasma Debye length) set at 5.10,20 and 30. Values of the potential drops at the sheath boundaries are presented

  5. Jet length/velocity ratio: a new index for echocardiographic evaluation of chronic aortic regurgitation.

    Science.gov (United States)

    Güvenç, Tolga Sinan; Karaçimen, Denizhan; Erer, Hatice Betül; İlhan, Erkan; Sayar, Nurten; Karakuş, Gültekin; Çekirdekçi, Elif; Eren, Mehmet

    2015-01-01

    Management of aortic regurgitation depends on the assessment for severity. Echocardiography remains as the most widely available tool for evaluation of aortic regurgitation. In this manuscript, we describe a novel parameter, jet length/velocity ratio, for the diagnosis of severe aortic regurgitation. A total of 30 patients with aortic regurgitation were included to this study. Severity of aortic regurgitation was assessed with an aortic regurgitation index incorporating five echocardiographic parameters. Jet length/velocity ratio is calculated as the ratio of maximum jet penetrance to mean velocity of regurgitant flow. Jet length/velocity ratio was significantly higher in patients with severe aortic regurgitation (2.03 ± 0.53) compared to patients with less than severe aortic regurgitation (1.24 ± 0.32, P < 0.001). Correlation of jet length/velocity ratio with aortic regurgitation index was very good (r(2) = 0.86) and correlation coefficient was higher for jet length/velocity ratio compared to vena contracta, jet width/LVOT ratio and pressure half time. For a cutoff value of 1.61, jet length/velocity ratio had a sensitivity of 92% and specificity of 88%, with an AUC value of 0.955. Jet length/velocity ratio is a novel parameter that can be used to assess severity of chronic aortic regurgitation. Main limitation for usage of this novel parameter is jet impringement to left ventricular wall. © 2014, Wiley Periodicals, Inc.

  6. Comparison of CT-Determined Pulmonary Artery Diameter, Aortic Diameter, and Their Ratio in Healthy and Diverse Clinical Conditions.

    Directory of Open Access Journals (Sweden)

    Sang Hoon Lee

    Full Text Available The main pulmonary artery diameter (mPA, aortic diameter (Ao, and the mPA/Ao ratio, easily measured using chest computed tomography (CT, provide information that enables the diagnosis and evaluation of cardiopulmonary diseases. Here, we used CT to determine the sex- and age-specific distribution of normal reference values for mPA, Ao, and mPA/Ao ratio in an adult Korean population.Data from non-contrast, ECG-gated, coronary-calcium-scoring CT images of 2,547 individuals who visited the Health Screening Center of the Severance Hospital were analyzed. Healthy individuals (n = 813 included those who do not have hypertension, diabetes, asthma, obstructive lung disease, ischemic heart disease, stroke, smoking, obesity, and abnormal CT findings. Both mPA and Ao were measured at the level of bifurcation of the main pulmonary artery.The mean mPA and Ao were 25.9 mm and 30.0 mm in healthy participants, respectively, while the mean mPA/Ao ratio was 0.87. Medical conditions associated with a larger mPA were male, obesity, smoking history, hypertension, and diabetes. A larger mPA/Ao ratio was associated with female, the obese, non-smoker, normotensive, and normal serum level of lipids, while a smaller mPA/Ao ratio was associated with older age. In healthy individuals, the 90th percentile sex-specific mPA, Ao, and mPA/Ao ratio were, 31.3 mm (95% CI 29.9-32.2, 36.8 mm (95% CI 35.7-37.5, and 1.05 (95% CI 0.99-1.07 in males, and 29.6 mm (95% CI 29.1-30.2, 34.5 mm (95% CI 34.1-34.9, and 1.03 (95% CI 1.02-1.06 in females, respectively.In the Korean population, the mean mPA reference values in male and female were 26.5 mm and 25.8 mm, respectively, while the mean mPA/Ao ratio was 0.87. These values were influenced by a variety of underlying medical conditions.

  7. Convective mixing length and the galactic carbon to oxygen ratio

    Energy Technology Data Exchange (ETDEWEB)

    Serrano, A; Peimbert, M [Universidad Nacional Autonoma de Mexico, Mexico City. Inst. de Astronomia

    1981-01-01

    We have studied chemical evolution models, assuming instantaneous recycling, and considering: a) the effects of mass loss both in massive stars and in intermediate mass stars, and b) the initial mass function of the solar neighbourhood (Serrano 1978). From these models we have derived the yields of carbon and oxygen. It is concluded that the condition C/O approximately 0.58 in the solar neighbourhood can only be satisfied if, during advanced stages of stellar evolution of intermediate mass stars, the ratio of the convective mixing length to the pressure scale height is > approximately 2.

  8. Developing high coercivity in large diameter cobalt nanowire arrays

    Science.gov (United States)

    Montazer, A. H.; Ramazani, A.; Almasi Kashi, M.; Zavašnik, J.

    2016-11-01

    Regardless of the synthetic method, developing high magnetic coercivity in ferromagnetic nanowires (NWs) with large diameters has been a challenge over the past two decades. Here, we report on the synthesis of highly coercive cobalt NW arrays with diameters of 65 and 80 nm, which are embedded in porous anodic alumina templates with high-aspect-ratio pores. Using a modified electrochemical deposition method enabled us to reach room temperature coercivity and remanent ratio up to 3000 Oe and 0.70, respectively, for highly crystalline as-synthesized hcp cobalt NW arrays with a length of 8 μm. The first-order reversal curve (FORC) analysis showed the presence of both soft and hard magnetic phases along the length of the resulting NWs. To develop higher coercive fields, the length of the NWs was then gradually reduced in order from bottom to top, thereby reaching NW sections governed by the hard phase. Consequently, this resulted in record high coercivities of 4200 and 3850 Oe at NW diameters of 65 and 80 nm, respectively. In this case, the FORC diagrams confirmed a significant reduction in interactions between the magnetic phases of the remaining sections of NWs. At this stage, x-ray diffraction (XRD) and dark-field transmission electron microscopy analyses indicated the formation of highly crystalline bamboo-like sections along the [0 0 2] direction during a progressive pulse-controlled electrochemical growth of NW arrays under optimized parameters. Our results both provide new insights into the growth process, crystalline characteristics and magnetic phases along the length of large diameter NW arrays and, furthermore, develop the performance of pure 3d transition magnetic NWs.

  9. Kerosene-water separation in T-junction with orientation upward branch with a 60° angle: Variation of diameter ratio

    Science.gov (United States)

    Puspitasari, Dewi; Indarto, Purnomo, Khasani

    2016-06-01

    Research on the T-junction is still underway for the flow of liquid-liquid (kerosene-water). Some research on the characteristics of kerosene-water separation was performed using T-junction oriented upward branch with a 60° angle. To observe the effect of diameters ratio on the phase separation that produced T-junction then made a test section with a horizontal pipe diameter 36 mm, while the side arm 36 mm diameter, 26 mm and 19 mm (diameters ratio of 1, 0.7 and 0.5) by using plexiglass pipe type. Based on experimental results and visualization of data flow in the test section, to the value obtained 60% water cut, the maximum separation efficiency of 94%, FK = 0.94 and FW = 0.001 with a diameter ratio of 1. For other diameter ratio of 0.7 and 0.5 respectively separation efficiency of 66%, FK = 1 and Fw = 0.34 for 0.7 and separation efficiency of 84%, FK = 1 and Fw = 0.16 for 0.5, the best value is obtained at a water cut 60% too. All the best conditions to achieve the above-stratified flow pattern.

  10. Biomechanical optimization of implant diameter and length for immediate loading: a nonlinear finite element analysis.

    Science.gov (United States)

    Kong, Liang; Gu, Zexu; Li, Tao; Wu, Junjie; Hu, Kaijin; Liu, Yanpu; Zhou, Hongzhi; Liu, Baolin

    2009-01-01

    A nonlinear finite element method was applied to examine the effects of implant diameter and length on the maximum von Mises stresses in the jaw, and to evaluate the maximum displacement of the implant-abutment complex in immediate-loading models. The implant diameter (D) ranged from 3.0 to 5.0 mm and implant length (L) ranged from 6.0 to 16.0 mm. The results showed that the maximum von Mises stress in cortical bone was decreased by 65.8% under a buccolingual load with an increase in D. In cancellous bone, it was decreased by 71.5% under an axial load with an increase in L. The maximum displacement in the implant-abutment complex decreased by 64.8% under a buccolingual load with an increase in D. The implant was found to be more sensitive to L than to D under axial loads, while D played a more important role in enhancing its stability under buccolingual loads. When D exceeded 4.0 mm and L exceeded 11.0 mm, both minimum stress and displacement were obtained. Therefore, these dimensions were the optimal biomechanical selections for immediate-loading implants in type B/2 bone.

  11. Evaluation of right atrium-to-right ventricle diameter ratio on computed tomography pulmonary angiography: Prediction of adverse outcome and 30-day mortality.

    Science.gov (United States)

    Oz, Ibrahim Ilker; Altınsoy, Bülent; Serifoglu, Ismail; Sayın, Rasit; Buyukuysal, Mustafa Cagatay; Erboy, Fatma; Akduman, Ece Isin

    2015-12-01

    The aim of this study was to examine the association between right atrium (RA) and right ventricle (RV) diameters on computed tomography (CT) pulmonary angiography in response to acute pulmonary embolism (APE), in addition to 30-day mortality and adverse outcomes in patients with APE. This retrospective study was accepted by the institutional ethics committee. From January 2013 to March 2014, 79 hospitalized adult patients with symptomatic APE were included. Inclusion criteria were a CT pulmonary angiography positive for pulmonary embolism, availability of patient records, and a follow-up of at least 30 days. A review of patient records and images was performed. The maximum diameters of the heart chambers were measured on a reconstructed four-chamber heart view, and the vascular obstruction index was calculated on CT pulmonary angiography. There were statistically significant relationships in both the RA/RV diameter ratio and the RV/left ventricle (LV) diameter ratio between patients with and without adverse outcomes (prights reserved.

  12. Finite Element Analysis of Bone Stress around Micro-Implants of Different Diameters and Lengths with Application of a Single or Composite Torque Force.

    Science.gov (United States)

    Lu, Ying-juan; Chang, Shao-hai; Ye, Jian-tao; Ye, Yu-shan; Yu, Yan-song

    2015-01-01

    Stress on the bone surrounding dental micro-implants affects implant success. To compare the stress on the bone surrounding a micro-implant after application of a single force (SF) of 200 g or a composite force (CF) of 200 g and 6 N.mm torque. Finite element models were developed for micro-implant diameters of 1.2, 1.6, and 2.0 mm, and lengths of 6, 8, 10, and 12 mm and either a SF or CF was applied. The maximum equivalent stress (Max EQS) of the bone surrounding the micro-implant was determined, and the relationships among type of force, diameter, and length were evaluated. The Max EQS of the CF exceeded that of the SF (Pimplant diameter, but not to implant length. The larger CF led to greater instability of the micro-implant and the effect was most pronounced at an implant diameter of 1.2 mm. The use of implant diameters of 1.6 mm and 2.0 mm produced no significant difference in implant stability when either a CF or SF was applied. When considering the use of an implant to perform three-dimensional control on the teeth, the implant diameter chosen should be > 1.2 mm.

  13. Pulmonary arterial hypertension in children: diagnosis using ratio of main pulmonary artery to ascending aorta diameter as determined by multi-detector computed tomography.

    Science.gov (United States)

    Caro-Domínguez, Pablo; Compton, Gregory; Humpl, Tilman; Manson, David E

    2016-09-01

    The ratio of the transverse diameter of the main pulmonary artery (MPA) to ascending aorta as determined at multi-detector CT is a tool that can be used to assess the pulmonary arterial size in cases of pulmonary arterial hypertension in children. To establish a ratio of MPA to ascending aorta diameter using multi-detector CT imaging suggestive of pulmonary arterial hypertension in children. We hypothesize that a defined ratio of MPA to ascending aorta is identifiable on multi-detector CT and that higher ratios can be used to reliably diagnose the presence of pulmonary arterial hypertension in children. We calculated the multi-detector CT ratio of MPA to ascending aorta diameter in 44 children with documented pulmonary arterial hypertension by right heart catheterization and in 44 age- and gender-matched control children with no predisposing factors for pulmonary arterial hypertension. We compared this multi-detector-CT-determined ratio with the MPA pressure in the study group, as well as with the ratio of MPA to ascending aorta in the control group. A threshold ratio value was calculated to accurately identify children with pulmonary arterial hypertension. Children with documented primary pulmonary arterial hypertension have a significantly higher ratio of MPA to ascending aorta (1.46) than children without pulmonary arterial hypertension (1.11). A ratio of 1.3 carries a positive likelihood of 34 and a positive predictive value of 97% for the diagnosis of pulmonary arterial hypertension. The pulmonary arteries were larger in children with pulmonary arterial hypertension than in a control group of normal children. A CT-measured ratio of MPA to ascending aorta of 1.3 should raise the suspicion of pulmonary arterial hypertension in children.

  14. SU-E-I-28: Introduction and Investigation of Effective Diameter Ratios as a New Patient Size Metric for Use in CT

    Energy Technology Data Exchange (ETDEWEB)

    Lamoureux, R [Gainesville, FL (United States); Sinclair, L [Portland, OR (United States); Mench, A [Salem Health, Tualatin, OR (United States); Lipnharski, I; Carranza, C; Bidari, S [University of Florida, Gainesville, FL (United States); Cormack, B [UF Health, Gainesville, FL (United States); Rill, L [Univ Florida, Jacksonville Beach, FL (United States); Arreola, M [University of Florida Health Science Center, Gainesville, FL (United States)

    2015-06-15

    Purpose: To introduce and investigate effective diameter ratios as a new patient metric for use in computed tomography protocol selection as a supplement to patient-specific size parameter data. Methods: The metrics of outer effective diameter and inner effective diameter were measured for 7 post-mortem subjects scanned with a standardized chest/abdomen/pelvis (CAP) protocol on a 320-slice MDCT scanner. The outer effective diameter was calculated by obtaining the anterior/posterior and lateral dimensions of the imaged anatomy at the middle of the scan range using Effective Diameter= SQRT(AP height*Lat Width). The inner effective diameter was calculated with the same equation using the AP and Lat dimensions of the anatomy excluding the adipose tissue. The ratio of outer to inner effective diameter was calculated for each subject. A relationship to BMI, weight, and CTDI conversion coefficients was investigated. Results: For the largest subject with BMI of 43.85 kg/m2 and weight of 255 lbs the diameter ratio was calculated as 1.33. For the second largest subject with BMI of 33.5 kg/m2 and weight of 192.4 lbs the diameter ratio was measured as 1.43, indicating a larger percentage of adipose tissue in the second largest subject’s anatomical composition. For the smallest subject at BMI of 17.4 kg/m2 and weight of 86 lbs a similar tissue composition was indicated as a subject with BMI of 24.2 kg/m2 and weight of 136 lbs as they had the same diameter ratios of 1.11. Conclusion: The diameter ratio proves to contain information about anatomical composition that the BMI and weight alone do not. The utility of this metric is still being examined but could prove useful for determining MDCT techniques and for giving a more in depth detail of the composition of a patient’s body habitus.

  15. Scalability of pre-packed preparative chromatography columns with different diameters and lengths taking into account extra column effects.

    Science.gov (United States)

    Schweiger, Susanne; Jungbauer, Alois

    2018-02-16

    Small pre-packed columns are commonly used to estimate the optimum run parameters for pilot and production scale. The question arises if the experiments obtained with these columns are scalable, because there are substantial changes in extra column volume when going from a very small scale to a benchtop column. In this study we demonstrate the scalability of pre-packed disposable and non-disposable columns of volumes in the range of 0.2-20 ml packed with various media using superficial velocities in the range of 30-500 cm/h. We found that the relative contribution of extra column band broadening to total band broadening was not only high for columns with small diameters, but also for columns with a larger volume due to their wider diameter. The extra column band broadening can be more than 50% for columns with volumes larger than 10 ml. An increase in column diameter leads to high additional extra column band broadening in the filter, frits, and adapters of the columns. We found a linear relationship between intra column band broadening and column length, which increased stepwise with increases in column diameter. This effect was also corroborated by CFD simulation. The intra column band broadening was the same for columns packed with different media. An empirical engineering equation and the data gained from the extra column effects allowed us to predict the intra, extra, and total column band broadening just from column length, diameter, and flow rate. Copyright © 2018 The Author(s). Published by Elsevier B.V. All rights reserved.

  16. Effect of chord-to-diameter ratio on vertical-axis wind turbine wake development

    Science.gov (United States)

    Parker, Colin M.; Araya, Daniel B.; Leftwich, Megan C.

    2017-12-01

    The wake structure of a vertical-axis wind turbine (VAWT) is strongly dependent on the tip-speed ratio, λ, or the tangential speed of the turbine blade relative to the incoming wind speed. The geometry of a turbine can influence λ, but the precise relationship among VAWT geometric parameters and VAWT wake characteristics remains unknown. To investigate this relationship, we present the results of an experiment to characterize the wakes of three VAWTs that are geometrically similar except for the ratio of the turbine diameter ( D), to blade chord ( c), which was chosen to be D/c = 3, 6, and 9. For a fixed freestream Reynolds number based on the blade chord of Re_c = 1.6× 10^3, both two-component particle image velocimetry (PIV) and single-component hot-wire anemometer measurements are taken at the horizontal mid-plane in the wake of each turbine. PIV measurements are ensemble averaged in time and phase averaged with each rotation of the turbine. Hot-wire measurement points are selected to coincide with the edge of the shear layer of each turbine wake, as deduced from the PIV data, which allows for an analysis of the frequency content of the wake due to vortex shedding by the turbine.

  17. Pulmonary arterial hypertension in children: diagnosis using ratio of main pulmonary artery to ascending aorta diameter as determined by multi-detector computed tomography

    International Nuclear Information System (INIS)

    Caro-Dominguez, Pablo; Manson, David E.; Compton, Gregory; Humpl, Tilman

    2016-01-01

    The ratio of the transverse diameter of the main pulmonary artery (MPA) to ascending aorta as determined at multi-detector CT is a tool that can be used to assess the pulmonary arterial size in cases of pulmonary arterial hypertension in children. To establish a ratio of MPA to ascending aorta diameter using multi-detector CT imaging suggestive of pulmonary arterial hypertension in children. We hypothesize that a defined ratio of MPA to ascending aorta is identifiable on multi-detector CT and that higher ratios can be used to reliably diagnose the presence of pulmonary arterial hypertension in children. We calculated the multi-detector CT ratio of MPA to ascending aorta diameter in 44 children with documented pulmonary arterial hypertension by right heart catheterization and in 44 age- and gender-matched control children with no predisposing factors for pulmonary arterial hypertension. We compared this multi-detector-CT-determined ratio with the MPA pressure in the study group, as well as with the ratio of MPA to ascending aorta in the control group. A threshold ratio value was calculated to accurately identify children with pulmonary arterial hypertension. Children with documented primary pulmonary arterial hypertension have a significantly higher ratio of MPA to ascending aorta (1.46) than children without pulmonary arterial hypertension (1.11). A ratio of 1.3 carries a positive likelihood of 34 and a positive predictive value of 97% for the diagnosis of pulmonary arterial hypertension. The pulmonary arteries were larger in children with pulmonary arterial hypertension than in a control group of normal children. A CT-measured ratio of MPA to ascending aorta of 1.3 should raise the suspicion of pulmonary arterial hypertension in children. (orig.)

  18. Pulmonary arterial hypertension in children: diagnosis using ratio of main pulmonary artery to ascending aorta diameter as determined by multi-detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Caro-Dominguez, Pablo; Manson, David E. [University of Toronto, Department of Diagnostic Imaging, The Hospital for Sick Children, Department of Medical Imaging, Toronto, ON (Canada); Compton, Gregory [University of Toronto, Department of Diagnostic Imaging, The Hospital for Sick Children, Department of Medical Imaging, Toronto, ON (Canada); Epworth Hospital, Epworth Medical Imaging, Richmond, VIC (Australia); Humpl, Tilman [University of Toronto, Division of Cardiology, Department of Pediatrics, The Hospital for Sick Children, Toronto, ON (Canada)

    2016-09-15

    The ratio of the transverse diameter of the main pulmonary artery (MPA) to ascending aorta as determined at multi-detector CT is a tool that can be used to assess the pulmonary arterial size in cases of pulmonary arterial hypertension in children. To establish a ratio of MPA to ascending aorta diameter using multi-detector CT imaging suggestive of pulmonary arterial hypertension in children. We hypothesize that a defined ratio of MPA to ascending aorta is identifiable on multi-detector CT and that higher ratios can be used to reliably diagnose the presence of pulmonary arterial hypertension in children. We calculated the multi-detector CT ratio of MPA to ascending aorta diameter in 44 children with documented pulmonary arterial hypertension by right heart catheterization and in 44 age- and gender-matched control children with no predisposing factors for pulmonary arterial hypertension. We compared this multi-detector-CT-determined ratio with the MPA pressure in the study group, as well as with the ratio of MPA to ascending aorta in the control group. A threshold ratio value was calculated to accurately identify children with pulmonary arterial hypertension. Children with documented primary pulmonary arterial hypertension have a significantly higher ratio of MPA to ascending aorta (1.46) than children without pulmonary arterial hypertension (1.11). A ratio of 1.3 carries a positive likelihood of 34 and a positive predictive value of 97% for the diagnosis of pulmonary arterial hypertension. The pulmonary arteries were larger in children with pulmonary arterial hypertension than in a control group of normal children. A CT-measured ratio of MPA to ascending aorta of 1.3 should raise the suspicion of pulmonary arterial hypertension in children. (orig.)

  19. Spatial age-length key modelling using continuation ratio logits

    DEFF Research Database (Denmark)

    Berg, Casper W.; Kristensen, Kasper

    2012-01-01

    -called age-length key (ALK) is then used to obtain the age distribution. Regional differences in ALKs are not uncommon, but stratification is often problematic due to a small number of samples. Here, we combine generalized additive modelling with continuation ratio logits to model the probability of age...

  20. DESIGN OF PARTICULATE MATERIAL COMPACTOR ROLLS DIAMETER

    Directory of Open Access Journals (Sweden)

    Peter Peciar

    2017-09-01

    Full Text Available At present, in a period of an industrial expansion great emphasis is placed on the environment. That means aiming for a reduced energy consumption, and also lessening dustiness from very fine powder material. This category also includes particulate material agglomeration processes. Because this process is very energy-intensive, it is necessary to correctly design these devices. The aim of this paper is to focus on a theoretical design of a production compactor with the rolls diameter for an experimental particulate material, based on Johanson’s theory and experimentally measured material properties. The material used for experimental measurements was an NPK-based industrial fertilizer consisting of several components. The results of this paper is the dependence of the ratio of the maximum compression pressure to the initial compression pressure from the rolls diameter of the proposed compactor.

  1. Storage capacity for fissile material as a function of facility shape (room length-to-width ratio)

    International Nuclear Information System (INIS)

    Altschuler, S.J.

    1975-01-01

    The results of a previous study for applying surface density methods to square room of varying size are shown to be conservative for rectangular rooms as well. The surface density required to produce criticality has been calculated as a function of the facility length-to-width ratio for a variety of room widths and unit sizes, shapes, and fissile material compositions. For a length to width ratio greater than or equal to 6, the critical surface density is essentially constant. This allows further economies since more fissile material can be stored at a given subcritical value of k/ sub eff/(0.90) in a rectangular vault of given usable area than in a square one. (U.S.)

  2. INCLUSION RATIO BASED ESTIMATOR FOR THE MEAN LENGTH OF THE BOOLEAN LINE SEGMENT MODEL WITH AN APPLICATION TO NANOCRYSTALLINE CELLULOSE

    Directory of Open Access Journals (Sweden)

    Mikko Niilo-Rämä

    2014-06-01

    Full Text Available A novel estimator for estimating the mean length of fibres is proposed for censored data observed in square shaped windows. Instead of observing the fibre lengths, we observe the ratio between the intensity estimates of minus-sampling and plus-sampling. It is well-known that both intensity estimators are biased. In the current work, we derive the ratio of these biases as a function of the mean length assuming a Boolean line segment model with exponentially distributed lengths and uniformly distributed directions. Having the observed ratio of the intensity estimators, the inverse of the derived function is suggested as a new estimator for the mean length. For this estimator, an approximation of its variance is derived. The accuracies of the approximations are evaluated by means of simulation experiments. The novel method is compared to other methods and applied to real-world industrial data from nanocellulose crystalline.

  3. The study of the influence of the diameter ratio and blade number to the performance of the cross flow wind turbine by using 2D computational fluid dynamics modeling

    Science.gov (United States)

    Tjahjana, Dominicus Danardono Dwi Prija; Purbaningrum, Pradityasari; Hadi, Syamsul; Wicaksono, Yoga Arob; Adiputra, Dimas

    2018-02-01

    Cross flow turbine can be one of the alternative energies for regions with low wind speed. Collision between wind and the blades which happened two times caused the cross flow turbine to have high power coefficient. Some factors that influence the turbine power coefficient are diameter ratio and blade number. The objective of the research was to study the effect of the diameter ratio and the blade number to the cross flow wind turbine performance. The study was done in two dimensional (2D) computational fluid dynamics (CFD) simulation method using the ANSYS-Fluent software. The turbine diameter ratio were 0.58, 0.63, 0.68 and 0.73. The diameter ratio resulting in the highest power coefficient value was then simulated by varying the number of blades, namely 16, 20 and 24. Each variation was tested on the wind speed of 2 m/s and at the tip speed ratio (TSR) of 0.1 to 0.4 with the interval of 0.1. The wind turbine with the ratio diameter of 0.68 and the number of blades of 20 generated the highest power coefficient of 0.5 at the TSR of 0.3.

  4. The effect of shape, length and diameter of implants on primary stability based on resonance frequency analysis

    Directory of Open Access Journals (Sweden)

    Hamidreza Barikani

    2014-01-01

    Full Text Available Background: The aim of this in vitro study was to evaluate the effect of shape, diameter and length of implants on their primary stability based on resonance frequency analysis. Materials and Methods: Replace select tapered and Branemark MK III implants were selected. Each of these two selected groups was divided into nine subgroups based on the implant length (IL (short, medium and long and the implant diameter (ID (narrow platform [NP], regular platform [RP] and wide platform [WP]. Five implants were assigned to each of the nine subgroups. Implants were placed in artificial bone blocks with bone quality similar to D3 bone. Immediately after the implant placement, its primary stability was measured using Osstell Mentor equipment. T-test and Tukey′s honest significant difference Post hoc were performed for data analysis. Statistical significance was defined at P < 0.05. Results: Replace select system showed significantly higher primary stability compared to the Branemark system, when using the short implants for all three diameters (P ≤ 0.004. However, in medium length implants there were no significant differences between the two implant systems (P ≥ 0.31. In long implants, only when the NP and RP implants were used, the Replace Select system showed significantly higher primary stability compared to the Branemark system (P = 0.000. In the replace select system, long implants had a significantly higher primary stability compared to medium and short length implants (P ≤ 0.003. In the NP and RP Branemark implants, short implants showed significantly lower primary stability compared to medium and long implants (P ≤ 0.002. However, in WP Branemark implants, primary stability increased significantly with increasing the IL from short to medium and from medium to long (P = 0.000. There were also significant differences between NP and the two other wider implants in both systems (P = 0.000. Conclusion: The use of tapered implants is

  5. Aerodynamic Characteristics of a Flying-Boat Hull Having a Length-Beam Ratio of 15, TED No. NACA 2206

    Science.gov (United States)

    Riebe, John M.; Naeseth, Rodger L.

    1951-01-01

    An investigation was made in the Langley 300 MPH 7- by 10-foot tunnel to determine the aerodynamic characteristics of a flying-boat hull of a length-beam ratio of 15 in the presence of a wing. The investigation was an extension of previous tests made on hulls of length-beam ratios of 6, 9, and 12; these hulls were designed to have approximately the same hydrodynamic performance with respect to spray and resistance characteristics. Comparison with the previous investigation at lower length-beam ratios indicated a reduction in minimum drag coefficients of 0.0006 (10 peroent)with fixed transition when the length-beam ratio was extended from 12 to 15. As with the hulls of lower length-beam ratio, the drag reduction with a length-beam ratio of 15 occurred throughout the range of angle of attack tested and the angle of attack for minimum drag was in the range from 2deg to 3deg. Increasing the length-beam ratio from 12 to 15 reduced the hull longitudinal instability by an mount corresponding to an aerodynamic-center shift of about 1/2 percent of the mean aerodynamic chord of the hypothetical flying boat. At an angle of attack of 2deg, the value of the variation of yawing-moment coefficient with angle of yaw for a length-beam ratio of 15 was 0.00144, which was 0.00007 larger than the value for a length-beam ratio of 12.

  6. Computational study of fluid flow and heat transfer in composite packed beds of spheres with low tube to particle diameter ratio

    International Nuclear Information System (INIS)

    Yang, Jian; Wu, Jiangquan; Zhou, Lang; Wang, Qiuwang

    2016-01-01

    Highlights: • Flow and heat transfer in composite packed beds with low d_t/d_p_e are investigated. • The wall effect would be restrained with radially layered composite packing (RLM). • Heat flux and overall heat transfer efficiency can be improved with RLM packing. - Abstract: The effect of the tube wall on the fluid flow and heat transfer would be important in the packed bed with low tube to particle diameter ratio, which may lead to flow and temperature maldistributions inside, and the heat transfer performance may be lowered. In the present paper, the flow and heat transfer performances in both the composite and uniform packed beds of spheres with low tube to particle diameter were numerically investigated, where the composite packing means randomly packing with non-uniform spheres and the uniform packing means randomly packing with uniform spheres, including radially layered composite packing (RLM), axially layered composite packing (ALM), randomly composite packing (RCM) and randomly uniform packing (RPM). Both the composite and uniform packings were generated with discrete element method (DEM), and the influence of the wall effect on the flow and heat transfer in the packed beds were carefully studied and compared with each other. Firstly, it is found that, the wall effect on the velocity and temperature distributions in the randomly packed bed of uniform spheres (RPM) with low tube to particle diameter ratio were obvious. The average velocity of the near-tube-wall region is higher than that of the inner-tube region in the bed. When the tube wall is adiabatic, the average temperature of the near-tube-wall region is lower. With radially layered composite packing method (RLM), smaller pores would be formed close to the tube wall and big flow channels would be formed in the inner-tube region of the bed, which would be benefit to restrain the wall effect and improve heat transfer in the bed with low tube to particle diameter ratio. Furthermore, it is also

  7. Computational study of fluid flow and heat transfer in composite packed beds of spheres with low tube to particle diameter ratio

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Jian, E-mail: yangjian81@mail.xjtu.edu.cn [Key Laboratory of Thermo-Fluid Science and Engineering, Ministry of Education, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an, Shaanxi 710049 (China); Wu, Jiangquan [CSR Research of Electrical Technology and Material Engineering, Zhuzhou, Hunan 412001 (China); Zhou, Lang; Wang, Qiuwang [Key Laboratory of Thermo-Fluid Science and Engineering, Ministry of Education, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an, Shaanxi 710049 (China)

    2016-04-15

    Highlights: • Flow and heat transfer in composite packed beds with low d{sub t}/d{sub pe} are investigated. • The wall effect would be restrained with radially layered composite packing (RLM). • Heat flux and overall heat transfer efficiency can be improved with RLM packing. - Abstract: The effect of the tube wall on the fluid flow and heat transfer would be important in the packed bed with low tube to particle diameter ratio, which may lead to flow and temperature maldistributions inside, and the heat transfer performance may be lowered. In the present paper, the flow and heat transfer performances in both the composite and uniform packed beds of spheres with low tube to particle diameter were numerically investigated, where the composite packing means randomly packing with non-uniform spheres and the uniform packing means randomly packing with uniform spheres, including radially layered composite packing (RLM), axially layered composite packing (ALM), randomly composite packing (RCM) and randomly uniform packing (RPM). Both the composite and uniform packings were generated with discrete element method (DEM), and the influence of the wall effect on the flow and heat transfer in the packed beds were carefully studied and compared with each other. Firstly, it is found that, the wall effect on the velocity and temperature distributions in the randomly packed bed of uniform spheres (RPM) with low tube to particle diameter ratio were obvious. The average velocity of the near-tube-wall region is higher than that of the inner-tube region in the bed. When the tube wall is adiabatic, the average temperature of the near-tube-wall region is lower. With radially layered composite packing method (RLM), smaller pores would be formed close to the tube wall and big flow channels would be formed in the inner-tube region of the bed, which would be benefit to restrain the wall effect and improve heat transfer in the bed with low tube to particle diameter ratio. Furthermore, it

  8. Recirculation zone length in renal artery is affected by flow spirality and renal-to-aorta flow ratio.

    Science.gov (United States)

    Javadzadegan, Ashkan; Fulker, David; Barber, Tracie

    2017-07-01

    Haemodynamic perturbations such as flow recirculation zones play a key role in progression and development of renal artery stenosis, which typically originate at the aorta-renal bifurcation. The spiral nature of aortic blood flow, division of aortic blood flow in renal artery as well as the exercise conditions have been shown to alter the haemodynamics in both positive and negative ways. This study focuses on the combinative effects of spiral component of blood flow, renal-to-aorta flow ratio and the exercise conditions on the size and distribution of recirculation zones in renal branches using computational fluid dynamics technique. Our findings show that the recirculation length was longest when the renal-to-aorta flow ratio was smallest. Spiral flow and exercise conditions were found to be effective in reducing the recirculation length in particular in small renal-to-aorta flow ratios. These results support the hypothesis that in renal arteries with small flow ratios where a stenosis is already developed an artificially induced spiral flow within the aorta may decelerate the progression of stenosis and thereby help preserve kidney function.

  9. Analysis of in-R12 CHF data: influence of hydraulic diameter and heating length; test of Weisman boiling crisis model

    International Nuclear Information System (INIS)

    Czop, V.; Herer, C.; Souyri, A.; Garnier, J.

    1993-09-01

    In order to progress on the comprehensive modelling of the boiling crisis phenomenon, Electricite de France (EDF), Commissariat a l'Energie Atomique (CEA) and FRAMATOME have set up experimental programs involving in-R12 tests: the EDF APHRODITE program and the CEA-EDF-FRAMATOME DEBORA program. The first phase in these programs aims to acquire critical heat flux (CHF) data banks, within large thermal-hydraulic parameter ranges, both in cylindrical and annular configurations, and with different hydraulic diameters and heating lengths. Actually, three data banks have been considered in the analysis, all of them concerning in-R12 round tube tests: - the APHRODITE data bank, obtained at EDF with a 13 mn inside diameter, - the DEBORA data bank, obtained at CEA with a 19.2 mm inside diameter, - the KRISTA data bank, obtained at KfK with a 8 mm inside diameter. The analysis was conducted using CHF correlations and with the help of an advanced mathematical tool using pseudo-cubic thin plate type Spline functions. Two conclusions were drawn: -no influence of the heating length on our CHF results, - the influence of the diameter on the CHF cannot be simply expressed by an exponential function of this parameter, as thermal-hydraulic parameters also have an influence. Some calculations with Weisman and Pei theoretical boiling crisis model have been compared to experimental values: fairly good agreement was obtained, but further study must focus on improving the modelling of the influence of pressure and mass velocity. (authors). 12 figs., 4 tabs., 21 refs

  10. Finger length ratio (2D:4D) correlates with physical aggression in men but not in women.

    Science.gov (United States)

    Bailey, Allison A; Hurd, Peter L

    2005-03-01

    Finger length ratio (2D:4D) is a sexually dimorphic trait. Men have relatively shorter second digits (index fingers) than fourth digits (ring fingers). Smaller, more masculine, digit ratios are thought to be associated with either higher prenatal testosterone levels or greater sensitivity to androgens, or both. Men with more masculine finger ratios are perceived as being more masculine and dominant by female observers, and tend to perform better in a number of physical sports. We hypothesized that digit ratio would correlate with propensity to engage in aggressive behavior. We examined the relationship between trait aggression, assayed using a questionnaire, and finger length ratio in both men and women. Men with lower, more masculine, finger length ratios had higher trait physical aggression scores (r(partial) = -0.21, N = 134, P = 0.028). We found no correlation between finger length ratio and any form of aggression in females. These results are consistent with the hypothesis that testosterone has an organizational effect on adult physical aggression in men.

  11. Retrospective cohort clinical investigation of a dental implant with a narrow diameter and short length for the partial rehabilitation of extremely atrophic jaws.

    Science.gov (United States)

    Maló, Paulo S; de Araújo Nobre, Miguel A; Lopes, Armando V; Ferro, Ana S

    2017-01-01

    We investigated the short-term clinical outcomes of narrow-diameter short-length implants for the fixed-prosthetic partial rehabilitation of extremely resorbed jaws. Twenty-three patients requiring partial rehabilitations with narrow-platform short-length implants in any jaw were included in this study. In total, 30 implants 3.3 mm in diameter and 7 (n = 15 implants) or 8.5 (n = 15 implants) mm in length were inserted. The primary outcome measure was implant cumulative survival rate (CSR); the secondary outcome measures were marginal bone resorption at 1 and 3 years and the incidence of biologic and mechanical complications. Five patients (21.7%) with six implants (20%) were lost to follow-up. Two implants failed in two patients, yielding a CSR at 3 years of follow-up of 93.4%. The average (standard deviation) marginal bone resorption was 1.34 mm (0.95 mm) after the first year and 1.38 mm (0.78 mm) after the third year. Biologic complications occurred in three patients; mechanical complications occurred in three patients. Despite the limitations of the study, our findings show that the use of new narrow-diameter short-length implants for the rehabilitation of extremely atrophic regions is viable in the short-term, and can be considered a treatment alternative in extremely resorbed jaws.

  12. Geometric interpretation of the ratio of overall diameter to rim crest diameter for lunar and terrestrial craters.

    Science.gov (United States)

    Siegal, B. S.; Wickman, F. E.

    1973-01-01

    An empirical linear relationship has been established by Pike (1967) between the overall diameter and the rim crest diameter for rimmed, flat-floored as well as bowl-shaped, lunar and terrestrial craters formed by impact and explosion. A similar relationship for experimentally formed fluidization craters has been established by Siegal (1971). This relationship is examined in terms of the geometry of the crater and the slope angles of loose materials. The parameter varies from 1.40 to 1.65 and is found to be dependent on mean interior flat floor radius, exterior and interior rim slope angles, angle of aperture of the crater cone, and the volume fraction of crater void accounted for in the rim. The range of the observed parameter can be understood in terms of simple crater geometry by realistic values of the five parameters.

  13. Mapping Variability in the Medusae Fossae Formation: Yardang Morphologies, Fluvial Reworking, and Crater Depth to Diameter Ratios

    Science.gov (United States)

    Khuller, A. R.; Kerber, L.

    2017-12-01

    The Medusae Fossae Formation (MFF) is a voluminous, fine-grained deposit thought to be of pyroclastic origin. While it contains widespread, well-preserved inverted fluvial features, its pervasive cover of dust means that little is known about its composition, and indirect means must be used to characterize its material properties. This project aims to correlate fluvial features in the Western MFF with other indicators of material strength: yardang morphology and crater depth-to-diameter ratios. For this work, Context Camera (CTX) images were used to map features of fluvial origin (inverted channels, sinuous ridges, alluvial fans). The presence of rounded, meso-yardangs in close proximity to fluvial features was also mapped. Crater depth-diameter (d/D) ratios (for craters 1-512km) were analyzed using a global Mars crater database (Robbins and Hynek, 2012) as a proxy for material strength. Approximately 1400 fluvial segments were mapped, with the most populous cluster located in Aeolis and Zephyria Plana. Rounded meso-yardangs were found to be common in areas that also have fluvial features. In agreement with previous work (Barlow, 1993), MFF craters were found to have a greater d/D ratio (0.0523) than the global mean (0.0511). Ratios between MFF lobes differ significantly, providing insight into the heterogeneity of induration within the formation. The deepest craters are found in Eumenides Dorsum and the shallowest in Aeolis Planum, consistent with a greater degree of induration and reworking in the western part of the formation where the fluvial features and "salt-playa" meso-yardangs are found. It also suggests that Eumenides, which is the tallest MFF outcrop, could also be the least compacted. The presence of long, complex, and sometimes overlapping branching networks imply multiple relative episodes of channel formation. Rounded meso-yardangs, which are associated with salt playa surfaces on Earth, provide additional evidence for the presence of liquid water

  14. Diameter Effect of Silver Nanorod Arrays to Surface-enhanced Raman Scattering

    International Nuclear Information System (INIS)

    Gu, Geun Hoi; Kim, Min Young; Yoon, Hyeok Jin; Suh, Jung Sang

    2014-01-01

    The effect the diameter of silver nanorod arrays whose distance between the nanorods was uniform at 65 nm have on Surface-enhanced Raman Scattering (SERS) has been studied by varying the diameter from 28 to 51 nm. Nanorod length was fixed at approximately 62 nm, which is the optimum length for SERS by excitation with a 632.8 nm laser line. The transverse and longitudinal modes of the surface plasmon of these silver nanorods were near 400 and 630 nm, respectively. The extinction of the longitudinal mode increased with increasing nanorod diameter, while the transverse mode did not change significantly. High-quality SERS spectra of p-aminothiophenol and benzenethiol adsorbed on the tips of the silver nanorods were observed by excitation with a 632.8 nm laser line. The SERS enhancement increased with increasing nanorod diameter. We concluded that the SERS enhancement increases when the diameter of silver nanorods is increased mainly by increasing the excitation efficiency of the longitudinal mode. The enhancement factor for the silver nanorods with a 51 nm diameter was approximately 2 Χ 10 7

  15. Effect of injection angle, density ratio, and viscosity on droplet formation in a microfluidic T-junction

    Directory of Open Access Journals (Sweden)

    Mohammad Yaghoub Abdollahzadeh Jamalabadi

    2017-07-01

    Full Text Available The T-junction microchannel device makes available a sharp edge to form micro-droplets from bio-material solutions. This article investigates the effects of injection angle, flow rate ratio, density ratio, viscosity ratio, contact angle, and slip length in the process of formation of uniform droplets in microfluidic T-junctions. The governing equations were solved by the commercial software. The results show that contact angle, slip length, and injection angles near the perpendicular and parallel conditions have an increasing effect on the diameter of generated droplets, while flow rate, density and viscosity ratios, and other injection angles had a decreasing effect on the diameter. Keywords: Microfluidics, Droplet formation, Flow rate ratio, Density ratio

  16. Immediate, short‐, and long‐term changes in tracheal stent diameter, length, and positioning after placement in dogs with tracheal collapse syndrome

    Science.gov (United States)

    Raske, Matthew; Berent, Allyson C.; McDougall, Renee; Lamb, Kenneth

    2018-01-01

    Background Intraluminal tracheal stenting is a minimally invasive procedure shown to have variable degrees of success in managing clinical signs associated with tracheal collapse syndrome (CTCS) in dogs. Objectives Identify immediate post‐stent changes in tracheal diameter, determine the extent of stent migration, and stent shortening after stent placement in the immediate‐, short‐, and long‐term periods, and evaluate inter‐observer reliability of radiographic measurements. Animals Fifty client‐owned dogs. Methods Retrospective study in which medical records were reviewed in dogs with CTCS treated with an intraluminal tracheal stent. Data collected included signalment, location, and type of collapse, stent diameter and length, and post‐stent placement radiographic follow‐up times. Radiographs were used to obtain pre‐stent tracheal measurements and post‐stent placement measurements. Results Immediate mean percentage change was 5.14%, 5.49%, and 21.64% for cervical, thoracic inlet, and intra‐thoracic tracheal diameters, respectively. Ultimate mean follow‐up time was 446 days, with mean percentage change of 2.55%, 15.09%, and 8.65% for cervical, thoracic inlet, and intra‐thoracic tracheal diameters, respectively. Initial mean stent length was 26.72% higher than nominal length and ultimate long‐term tracheal mean stent shortening was only 9.90%. No significant stent migration was identified in the immediate, short‐, or long‐term periods. Good inter‐observer agreement of radiographic measurements was found among observers of variable experience level. Conclusions and Clinical Importance Use of an intraluminal tracheal stent for CTCS is associated with minimal stent shortening with no clinically relevant stent migration after fluoroscopic placement. Precise stent sizing and placement techniques likely play important roles in avoiding these reported complications. PMID:29460368

  17. The Relationship of Body Length and Ratio Pappilla with Sex in Gobi Fish (Sicyopterus macrostetholepis

    Directory of Open Access Journals (Sweden)

    Rona Taula Sari

    2017-07-01

    Full Text Available Research about the relationship of body length and ratio papilla with sex in goby fish (S. macrostetholepis Blkr. has been done at Animal Structure and Developmental Laboratory, Biologi Department, Faculty of Matematics and Natural Sciences, Andalas University, Padang, which purposed to analyse the relationship of body length and ratio papilla with sex of goby fish (S. macrostetholepis Blkr.. The samples were taken in wild stream area at Batangkuranji river, Padang City. This research used descriptive method and data were analyzed by qualitatively and quantitatively. The results of investigation showed that in several goby fishes (S. macrostetholepis Blkr. with different sex had the same of body length and the same of ratio papilla. So, there was not relationship between of body length and ratio papilla with sex.  Goby fishes (S. macrostetholepis Blkr. it belongs to the hermaphrodite protogini, which the androgynous young females, while in adulthood, it would change sex to male. The results of this study are expected to add to the treasures of knowledge and information about reproductive gobies (S. macrostetholepis Blkr. in the preservation and development of fish farming.   

  18. Width/Length Ratio in Maxillary Anterior Teeth. Comparative Study of Esthetic Preferences among Professionals and Laypersons.

    Science.gov (United States)

    Álvarez-Álvarez, Lorena; Orozco-Varo, Ana; Arroyo-Cruz, Gema; Jiménez-Castellanos, Emilio

    2017-05-17

    Many studies have examined the esthetic preferences of professionals in the maxillary anterior region; however, only a few have taken into account the ratios that are more frequent within the population or other ratios suggested in the literature as ideal. Previous studies also failed to compare them with the esthetic preferences of the lay population with regards to the smile. The purpose of this study is to highlight the differences when perceiving the esthetics of smiles between general dentists and laypersons, and linking them with the width/length of the maxillary anterior teeth. Photographs of the full face of a female subject were modified with Photoshop CS regarding the length/width relationships of the 6 maxillary anterior teeth. The three modifications made were: (a) 80% length/width, (b) 85%, length/width, and (c) 85% length/width in central incisors, 80% length/width in lateral incisors and canines. Three sequences of photograph pairs were created with different ratios and presented in PowerPoint to a sample of 100 general dentists and 100 laypersons. The ratio considered as the most esthetic by the majority of the judges was 85% for central incisors and 80% for lateral incisors and canines, with a statistically significant difference (p esthetic preferences of the studied populations either due to gender or professional experience of the dentists (p > 0.01). According to the results obtained in this study, professionals and laypersons considered a width/length ratio of 85% for maxillary central incisors and 80% for lateral incisors and canines as the most esthetic for maxillary anterior teeth. These results do not support findings from other studies previously published with similar ratios in central incisors, lateral incisors, and canines. Today clinicians practice in a treatment environment where not only function and utility but also esthetics is demanded in almost every procedure. Restoring/maintaining function is considered essential in any

  19. The Golden ratio, ionic and atomic radii and bond lengths

    Czech Academy of Sciences Publication Activity Database

    Heyrovská, Rajalakshmi

    2005-01-01

    Roč. 103, 6-8 (2005), s. 877-882 ISSN 0026-8976 R&D Projects: GA MPO(CZ) 1H-PK/42 Institutional research plan: CEZ:AV0Z40400503 Keywords : Bohr radius * bond lengths * axial ratios Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 1.351, year: 2005

  20. Emphasis: Five Ways to Cure Boring Student Writing.

    Science.gov (United States)

    Foster, Mary Ellen

    A careful use of emphasis by students in their writing can be promoted by some exercises assigned by composition teachers. A drawing exercise can help students learn that changing the length of sentences makes paragraphs more interesting. Using Elizabeth Kubler-Ross's five categories of grief to consider times of depression in students' lives…

  1. Finger Length Ratio (2D:4D) in Central India and an Attempt to Verify Fraternal Birth Order Effect: A Population Based Cross-Sectional Study.

    Science.gov (United States)

    Maitra, Arjun; Maitra, Chaitali; Jha, Dilip Kumar; Biswas, Rakesh

    2016-12-01

    A normal physiology of a human being is not mere a series of functions occurring with specific intensities and timing. There are lot of factors that may change the normal physiological activity within normal limits. Finger length ratio is one of the markers of intrauterine androgen exposure and it is debated and contradicted by many authors. Digit ratio varies among the ethnicities. Many Indian studies show that there is considerable difference in finger length ratio in different population. Data regarding Central India was not found on extensive search. To find out the finger length ratio and explore the birth order effect on finger length ratio among the first two successive born in the said population. We conducted a survey on 1500 volunteer persons (800 male and 700 female) over two years of time. We measured the length of the index finger (2D) and ring finger (4D) of both the hands and asked about their birth order history to find out the digit ratio for Central India population and any existing correlation of the same with birth order. T Test and Analysis of Variance (ANOVA) were used for the measure of significance and difference among the groups. The peffect among the eldest, second born with elder brother and second born with elder sister groups, no significant (p>0.05) variation for finger length ratio of right and left hands observed in both male and female population. Our study reports that the finger length ratio (2D:4D) for Central India population did not show significant association between finger length ratio and fraternal birth order among the first two successive born.

  2. Immediate, short-, and long-term changes in tracheal stent diameter, length, and positioning after placement in dogs with tracheal collapse syndrome.

    Science.gov (United States)

    Raske, Matthew; Weisse, Chick; Berent, Allyson C; McDougall, Renee; Lamb, Kenneth

    2018-03-01

    Intraluminal tracheal stenting is a minimally invasive procedure shown to have variable degrees of success in managing clinical signs associated with tracheal collapse syndrome (CTCS) in dogs. Identify immediate post-stent changes in tracheal diameter, determine the extent of stent migration, and stent shortening after stent placement in the immediate-, short-, and long-term periods, and evaluate inter-observer reliability of radiographic measurements. Fifty client-owned dogs. Retrospective study in which medical records were reviewed in dogs with CTCS treated with an intraluminal tracheal stent. Data collected included signalment, location, and type of collapse, stent diameter and length, and post-stent placement radiographic follow-up times. Radiographs were used to obtain pre-stent tracheal measurements and post-stent placement measurements. Immediate mean percentage change was 5.14%, 5.49%, and 21.64% for cervical, thoracic inlet, and intra-thoracic tracheal diameters, respectively. Ultimate mean follow-up time was 446 days, with mean percentage change of 2.55%, 15.09%, and 8.65% for cervical, thoracic inlet, and intra-thoracic tracheal diameters, respectively. Initial mean stent length was 26.72% higher than nominal length and ultimate long-term tracheal mean stent shortening was only 9.90%. No significant stent migration was identified in the immediate, short-, or long-term periods. Good inter-observer agreement of radiographic measurements was found among observers of variable experience level. Use of an intraluminal tracheal stent for CTCS is associated with minimal stent shortening with no clinically relevant stent migration after fluoroscopic placement. Precise stent sizing and placement techniques likely play important roles in avoiding these reported complications. Copyright © 2018 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  3. Walk Ratio (Step Length/Cadence) as a Summary Index of Neuromotor Control of Gait: Application to Multiple Sclerosis

    Science.gov (United States)

    Rota, Viviana; Perucca, Laura; Simone, Anna; Tesio, Luigi

    2011-01-01

    In healthy adults, the step length/cadence ratio [walk ratio (WR) in mm/(steps/min) and normalized for height] is known to be constant around 6.5 mm/(step/min). It is a speed-independent index of the overall neuromotor gait control, in as much as it reflects energy expenditure, balance, between-step variability, and attentional demand. The speed…

  4. A phantom study on the effect of target diameter and target-to-background ratio on the measurement of SUVmax in PET

    International Nuclear Information System (INIS)

    Cui Yan; Chen Song; Li Yaming

    2013-01-01

    Objective: To investigate the effect of target diameter and target-to-background ratio (TBR) on the measurement of SUV max [| (true SUV-SUV max )/true SUV | × 100%, △SUV max ) in PET. Methods: Six cylinders with various diameters from 5 to 29 mm were inserted in National Electrical Manufacturers Association (NEMA) NU 2-1994 phantom. The six cylinders and background of phantom were filled with 18 F-FDG solution. Six different TBRs (1.79, 3.70, 6.25, 10.59, 14.87 and 17.88) were obtained by changing the 18 F-FDG concentration in the six cylinders. The PET data were acquired in the 2D mode, and the target's inner diameter and SUV max were measured. The logarithmic fitting curves of △SUV max with diameter in different TBRs using equations (y=aln(x)+b) were acquired by Microsoft excel, |a| as the influence power of diameter on △SUV max . Statistical analysis was performed with Pearson correlation test and curve estimation utilizing SPSS 17.0. Results: The Pearson correlation coefficient between △SUV max and diameter was-0.806 (P<0.01). △SUV max was inversely correlated with the diameter. When the diameter (the inner diameter measured on PET images) was 4.0 mm, △SUV max could be as high as 79.73% with different TBRs. The Pearson correlation coefficient between the influence power of diameter on △SUV max (|a|) and TBRs was 0.848 (P<0.05).When TBR was 6.25, 10.59 and 14.87, the corresponding |a| was similar: 38.019, 39.998 and 39.362, respectively. When TBR was 17.88, |a| was the highest as 43.234. When TBR was 1.79 and 3.70, |a| was much smaller: 14.141 and 23.411 respectively. Conclusions: The lesion diameter is inversely correlated with △SUV max . The influence power of diameter on △SUV max is strongly correlated with TBR. Therefore, the effect of target diameter and TBR on the measurement of SUV max should be taken into consideration for follow-up studies. (authors)

  5. Morphometric analysis of the diameter and g-ratio of the myelinated nerve fibers of the human sciatic nerve during the aging process.

    Science.gov (United States)

    Ugrenović, Sladjana; Jovanović, Ivan; Vasović, Ljiljana; Kundalić, Braca; Čukuranović, Rade; Stefanović, Vladisav

    2016-06-01

    Myelinated nerve fibers suffer from different degrees of atrophy with age. The success of subsequent regeneration varies. The aim of this research was to analyze myelinated fibers of the human sciatic nerve during the aging process. Morphometric analysis was performed on 17 cases with an age range from 9 to 93 years. The outer and inner diameter of 100 randomly selected nerve fibers was measured in each of the cases evaluated, and the g-ratio (axonal diameter/outer diameter of the whole nerve fiber) of each was calculated. Scatter plots of the diameters and g-ratios of the analyzed fibers were then analyzed. Nerve fibers of each case were classified into three groups according to the g-ratio values: group I (g-ratio lower than 0.6), group II (g-ratio from 0.6 to 0.7) and group III (g-ratio higher than 0.7). Afterwards, nerve fibers of group II were further classified into small and large subgroups. The percentages of each group of nerve fibers were computed for each case and these values were used for correlational and bivariate linear regression analysis. The percentage of myelinated nerve fibers with large diameter and optimal g-ratio of the sciatic nerve declines significantly with age. This is accompanied by a simultaneous significant increase in the percentage of small myelinated fibers with g-ratio values close to 1 that occupy the upper left quadrant of the scatter plot. It can be concluded that aging of the sciatic nerve is associated with significant atrophy of large myelinated fibers. Additionally, a significant increase in regenerated nerve fibers with thinner myelin sheath is observed with age, which, together with the large myelinated fiber atrophy, might be the cause of the age-related decline in conduction velocity. A better understanding of the changes in aging peripheral nerves might improve interpretation of their pathological changes, as well as comprehension of their regeneration in individuals of different age.

  6. Tuning the electronic properties by width and length modifications of narrow-diameter carbon nanotubes for nanomedicine

    KAUST Repository

    Poater, Albert; Saliner, Ana Gallegos; Cavallo, Luigi; Poch, Manel P.; Solà , Miquel; Worth, Andrew P.

    2012-01-01

    The distinctive characteristics of nanoparticles, resulting from properties that arise at the nano-scale, underlie their potential applications in the biomedical sector. However, the very same characteristics also result in widespread concerns about the potentially toxic effects of nanoparticles. Given the large number of nanoparticles that are being developed for possible biomedical use, there is a need to develop rapid screening methods based on in silico methods. This study illustrates the application of conceptual Density Functional Theory (DFT) to some carbon nanotubes (CNTs) optimized by means of static DFT calculations. The computational efforts are focused on the geometry of a family of packed narrow-diameter carbon nanotubes (CNTs) formed by units from four to twelve carbons evaluating the strength of the C-C bonds by means of Mayer Bond Orders (MBO). Thus, width and length are geometrical features that might be used to tune the electronic properties of the CNTs. At infinite length, partial semi-conductor characteristics are expected. © 2012 Bentham Science Publishers.

  7. Tuning the electronic properties by width and length modifications of narrow-diameter carbon nanotubes for nanomedicine

    KAUST Repository

    Poater, Albert

    2012-10-01

    The distinctive characteristics of nanoparticles, resulting from properties that arise at the nano-scale, underlie their potential applications in the biomedical sector. However, the very same characteristics also result in widespread concerns about the potentially toxic effects of nanoparticles. Given the large number of nanoparticles that are being developed for possible biomedical use, there is a need to develop rapid screening methods based on in silico methods. This study illustrates the application of conceptual Density Functional Theory (DFT) to some carbon nanotubes (CNTs) optimized by means of static DFT calculations. The computational efforts are focused on the geometry of a family of packed narrow-diameter carbon nanotubes (CNTs) formed by units from four to twelve carbons evaluating the strength of the C-C bonds by means of Mayer Bond Orders (MBO). Thus, width and length are geometrical features that might be used to tune the electronic properties of the CNTs. At infinite length, partial semi-conductor characteristics are expected. © 2012 Bentham Science Publishers.

  8. Quantitative analysis of length-diameter distribution and cross-sectional properties of fibers from three-dimensional tomographic images

    DEFF Research Database (Denmark)

    Miettinen, Arttu; Joffe, Roberts; Madsen, Bo

    2013-01-01

    obtained from optical microscopy of polished cross-sections of a composite. This approach gives accurate yet local results, but a rather large number of optical images have to be processed to achieve a representative description of the morphology of the material. In this work a fully automatic algorithm......A number of rule-of-mixture micromechanical models have been successfully used to predict the mechanical properties of short fiber composites. However, in order to obtain accurate predictions, a detailed description of the internal structure of the material is required. This information is often...... for estimating the length-diameter distribution of solid or hollow fibers, utilizing three-dimensional X-ray tomographic images, is presented. The method is based on a granulometric approach for fiber length distribution measurement, combined with a novel algorithm that relates cross-sectional fiber properties...

  9. Aspect ratio has no effect on genotoxicity of multi-wall carbon nanotubes.

    Science.gov (United States)

    Kim, Jin Sik; Lee, Kyu; Lee, Young Hee; Cho, Hyun Sun; Kim, Ki Heon; Choi, Kyung Hee; Lee, Sang Hee; Song, Kyung Seuk; Kang, Chang Soo; Yu, Il Je

    2011-07-01

    Carbon nanotubes (CNTs) have specific physico-chemical and electrical properties that are useful for telecommunications, medicine, materials, manufacturing processes and the environmental and energy sectors. Yet, despite their many advantages, it is also important to determine whether CNTs may represent a hazard to the environment and human health. Like asbestos, the aspect ratio (length:diameter) and metal components of CNTs are known to have an effect on the toxicity of carbon nanotubes. Thus, to evaluate the toxic potential of CNTs in relation to their aspect ratio and metal contamination, in vivo and in vitro genotoxicity tests were conducted using high-aspect-ratio (diameter: 10-15 nm, length: ~10 μm) and low-aspect-ratio multi-wall carbon nanotubes (MWCNTs, diameter: 10-15 nm, length: ~150 nm) according to OECD test guidelines 471 (bacterial reverse mutation test), 473 (in vitro chromosome aberration test), and 474 (in vivo micronuclei test) with a good laboratory practice system. To determine the treatment concentration for all the tests, a solubility and dispersive test was performed, and a 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC) solution found to be more suitable than distilled water. Neither the high- nor the low-aspect-ratio MWCNTs induced any genotoxicity in a bacterial reverse mutation test (~1,000 μg/plate), in vitro chromosome aberration test (without S9: ~6.25 μg/ml, with S9: ~50 μg/ml), or in vivo micronuclei test (~50 mg/kg). However, the high-aspect-ratio MWCNTs were found to be more toxic than the low-aspect-ratio MWCNTs. Thus, while high-aspect-ratio MWCNTs do not induce direct genotoxicity or metabolic activation-mediated genotoxicity, genotoxicity could still be induced indirectly through oxidative stress or inflammation.

  10. Haldane’s Rule Is Linked to Extraordinary Sex Ratios and Sperm Length in Stalk-Eyed Flies

    Science.gov (United States)

    Wilkinson, Gerald S.; Christianson, Sarah J.; Brand, Cara L.; Ru, George; Shell, Wyatt

    2014-01-01

    We use three allopatric populations of the stalk-eyed fly Teleopsis dalmanni from Southeast Asia to test two predictions made by the sex chromosome drive hypothesis for Haldane’s rule. The first is that modifiers that suppress or enhance drive should evolve rapidly and independently in isolated populations. The second is that drive loci or modifiers should also cause sterility in hybrid males. We tested these predictions by assaying the fertility of 2066 males derived from backcross experiments involving two pairs of populations and found that the proportion of mated males that fail to produce any offspring ranged from 38 to 60% among crosses with some males producing strongly female-biased or male-biased sex ratios. After genotyping each male at 25–28 genetic markers we found quantitative trait loci (QTL) that jointly influence male sterility, sperm length, and biased progeny sex ratios in each pair of populations, but almost no shared QTL between population crosses. We also discovered that the extant XSR chromosome has no effect on sex ratio or sterility in these backcross males. Whether shared QTL are caused by linkage or pleiotropy requires additional study. Nevertheless, these results indicate the presence of a “cryptic” drive system that is currently masked by suppressing elements that are associated with sterility and sperm length within but not between populations and, therefore, must have evolved since the populations became isolated, i.e., in hybrid sterility. PMID:25164880

  11. Fetal omphalocele ratios predict outcomes in prenatally diagnosed omphalocele.

    Science.gov (United States)

    Montero, Freddy J; Simpson, Lynn L; Brady, Paula C; Miller, Russell S

    2011-09-01

    The objective of the study was to evaluate whether ratios considering omphalocele diameter relative to fetal biometric measurements perform better than giant omphalocele designation at predicting inability to achieve neonatal primary surgical closure. Cases of fetal omphalocele that underwent evaluation between May 2003 and July 2010 were identified. Inclusion was restricted to live births with plan for postnatal repair. Omphalocele diameter upon antenatal ultrasound was compared with abdominal circumference, femur length, and head circumference, yielding the respective omphalocele (O)/abdominal circumference (AC), O/femur length (FL), and O/head circumference (HC) ratios. The absolute measurements were used to classify giant lesions. Omphalocele ratios and giant omphalocele designations were evaluated as predictors of inability to achieve primary repair. Among 25 included cases, staged or delayed closure occurred in 52%. With an optimal cutoff of 0.21 or greater, O/HC best predicted the primary outcome (sensitivity, 84.6%; specificity, 58.3%; odds ratio, 7.7). The O/HC of 0.21 or greater outperformed giant designations. The O/HC of 0.21 or greater best predicted staged or delayed omphalocele closure. Giant omphalocele designation, regardless of definition, poorly predicted outcome. Copyright © 2011 Mosby, Inc. All rights reserved.

  12. Comparison of Heidelberg Retina Tomograph with disc-macula distance to disc diameter ratio in diagnosing optic nerve hypoplasia.

    Science.gov (United States)

    Pang, Yi; Frantz, Kelly A

    2016-05-01

    To evaluate whether Heidelberg Retinal Tomograph (HRT) is a valid test for diagnosing congenital optic nerve hypoplasia (CONH) compared to the ratio of the distance between the centre of the optic disc and the centre of the macula and the mean optic disc diameter (DM:DD ratio). Furthermore, to determine the optimal cut-off value of HRT disc area to differentiate a hypoplastic disc from a normal optic disc. A total of 33 subjects with CONH (4-67 years old) and 160 normal subjects (5-65 years old) were recruited and underwent comprehensive eye examinations, fundus photography and HRT. Receiver operating characteristic curves for DM:DD ratio and HRT disc area were constructed based on data from the 46 CONH eyes and 160 control eyes. Mean (±S.D.) HRT disc area was 1.94 (±0.54) mm(2) for the control eyes and 0.84 (±0.35) mm(2) for the CONH eyes (p < 0.0001). The area under the curve (AUC) for DM:DD ratio was 0.83 (95% confidence interval: 0.76-0.90). The AUC for HRT disc area was 0.96 (95% confidence interval: 0.94-0.99). A statistically significant difference was found between AUC for HRT disc area and that for DM:DD ratio (p = 0.0004). The optimal cut-off value for HRT disc area was 1.42 mm(2) with 95% sensitivity and 85% specificity. The optimal cut-off value for DM:DD ratio was 3.20 with 78% sensitivity and 78% specificity. Both HRT and the DM:DD ratio are valid tests to aid diagnosis of CONH. HRT is superior to DM:DD ratio in diagnosing CONH with higher sensitivity and specificity. We suggest the optimal cut-off value for HRT disc area as 1.42 mm(2) in order to discriminate a hypoplastic disc from a normal optic disc. © 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.

  13. The Ratio of Second to Fourth Digit Length (2D:4D in Children with Autistic Disorder

    Directory of Open Access Journals (Sweden)

    Javad Baharara

    2014-11-01

    Full Text Available Introduction Emerging hypotheses suggest a causal role for prenatal androgen exposure in some cases of Autism spectrum disorders (ASD. The ratios of the lengths of the bones of the 2nd to the 4th digits (2D:4D are purported to be markers for prenatal androgen exposure and to be established early in gestation. Ratio of second and fourth digits (2D:4D  is usually used as a proxy for prenatal testosterone. Methods and Materials In this study, 2D:4D in 48 children with ASD and in 41  control child was measured. Two groups were matched with the gender and age. Both groups were selected by convenience sampling method. All statistical analyses were performed using SPSS 19.0 software, considering as significant less than .05 (p < .05. Results: Results showed that the average ratio of 2D:4D in ASD children were lower than the ratio in control children (P

  14. Operating experience with small diameter bellows used in the Phenix and Rapsodie reactors, and in sodium test facilities

    International Nuclear Information System (INIS)

    Allegre, P.; Jacquelin, R.; Carbonnier, J.L.

    1980-01-01

    In the Rapsodie and Phenix fast breeder reactors, small diameter bellows are used on the control rod mechanisms and on some valves. The Valve bellows sustain slow longitudinal movements with stroke/length ratios of about 0.3, and hydroformed bellows are suitable for this application. The control rod mechanism bellows are subjected to greater length variations (ΔL/L>0.5) including fast drops, so that welded disk models are used

  15. Optical 'dampening' of the refractive error to axial length ratio: implications for outcome measures in myopia control studies.

    Science.gov (United States)

    Cruickshank, Fiona E; Logan, Nicola S

    2018-05-01

    To gauge the extent to which differences in the refractive error axial length relationship predicted by geometrical optics are observed in actual refractive/biometric data. This study is a retrospective analysis of existing data. Right eye refractive error [RX] and axial length [AXL] data were collected on 343 6-to-7-year-old children [mean 7.18 years (S.D. 0.35)], 294 12-to-13-year-old children [mean 13.12 years (S.D. 0.32)] and 123 young adults aged 18-to-25-years [mean 20.56 years (S.D. 1.91)]. Distance RX was measured with the Shin-Nippon NVision-K 5001 infrared open-field autorefractor. Child participants were cyclopleged prior to data collection (1% Cyclopentolate Hydrochloride). Myopia was defined as a mean spherical equivalent [MSE] ≤-0.50 D. Axial length was measured using the Zeiss IOLMaster 500. Optical modelling was based on ray tracing and manipulation of parameters of a Gullstrand reduced model eye. There was a myopic shift in mean MSE with age (6-7 years +0.87 D, 12-13 years -0.06 D and 18-25 years -1.41 D), associated with an increase in mean AXL (6-7 years 22.70 mm, 12-13 years 23.49 mm and 18-25 years 23.98 mm). There was a significant negative correlation between MSE and AXL for all age groups (all p theory predicts that there will be a reduction in the RX: AXL ratio with longer eyes. The participant data although adhering to this theory show a reduced effect, with eyes with longer axial lengths having a lower refractive error to axial length ratio than predicted by model eye calculations. We propose that in myopia control intervention studies when comparing efficacy, consideration should be given to the dampening effect seen with a longer eye. © 2018 The Authors. Ophthalmic and Physiological Optics published by John Wiley & Sons Ltd on behalf of College of Optometrists.

  16. Relationship between width and length ratios of upper anterior teeth in young Chilean population.

    Directory of Open Access Journals (Sweden)

    Jorge Troncoso-Pazos

    2017-08-01

    Full Text Available Introduction: Knowledge about the size and proportion of upper anterior teeth allows dental rehabilitation taking into consideration the local parameters of a population. The aim of this research is to determine the width, length and the relationship between width and length of central incisor, lateral incisor and canine teeth in both sexes in young Chilean population. Methodology: A cross-sectional study was performed. Study subjects included 187 dentistry students from two Chilean cities (mean age 21.35±2.7 years, 52.9% men. The teeth width and height were measured and the width/height ratio was calculated. Differences in measurements according to sex was analyzed (p<0.05; STATA v.10.0. Results: The width and height of the teeth were statistically and proportionally larger in men (p<0.05. The width/height ratio of lateral and canine incisors was significantly higher in women (p<0.05. Conclusion: In a sample of young Chileans, upper anterior teeth were longer and wider in men. However, the width/height ratio of teeth was found to be significantly higher in women.

  17. Impact of stent diameter and length on in-stent restenosis after DES vs BMS implantation in patients needing large coronary stents-A clinical and health-economic evaluation.

    Science.gov (United States)

    Zbinden, Rainer; von Felten, Stefanie; Wein, Bastian; Tueller, David; Kurz, David J; Reho, Ivano; Galatius, Soren; Alber, Hannes; Conen, David; Pfisterer, Matthias; Kaiser, Christoph; Eberli, Franz R

    2017-02-01

    The British National Institute of Clinical Excellence (NICE) guidelines recommend to use drug-eluting stents (DES) instead of bare-metal stents (BMS) only in lesions >15 mm in length or in vessels stent length and stent diameter on in-stent restenosis (ISR) in the BASKET-PROVE study population and evaluated the cost-effectiveness of DES compared to BMS. The BASKET-PROVE trial compared DES vs BMS in large coronary arteries (≥3 mm). We calculated incremental cost-effectiveness ratios (ICERs) and cost-effectiveness acceptability curves with regard to quality-adjusted life years (QALYs) gained and target lesion revascularizations (TLRs) avoided. A total of 2278 patients were included in the analysis. A total of 74 ISR in 63 patients were observed. In-stent restenosis was significantly more frequent in segments treated with a BMS compared to segments treated with a DES (5.4% vs 0.76%; Pstent length >15 mm and ≤15 mm, respectively. With the use of DES in short lesions, there was only a minimal gain of 0.005 in QALYs. At a threshold of 10 000 CHF per TLR avoided, DES had a high probability of being cost-effective. In the BASKET-PROVE study population, the strongest predictor of ISR is the use of a BMS, even in patients in need of stents ≥3.0 mm and ≤15 mm lesion length and DES were cost-effective. This should prompt the NICE to reevaluate its recommendation to use DES instead of BMS only in vessels 15 mm length. © 2016 John Wiley & Sons Ltd.

  18. Dependence of CuO particle size and diameter of reaction tubing on tritium recovery for tritium safety operation

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Cui, E-mail: cdxohc10000@163.com [Shizuoka University, 836 Ohya, Suruga-ku Shizuoka 422-8529 (Japan); Uemura, Yuki; Yuyama, Kenta; Fujita, Hiroe; Sakurada, Shodai; Azuma, Keisuke [Shizuoka University, 836 Ohya, Suruga-ku Shizuoka 422-8529 (Japan); Taguchi, Akira; Hara, Masanori; Hatano, Yuji [University of Toyama, 3190 Gofuku, Toyama 939-8555 (Japan); Chikada, Takumi; Oya, Yasuhisa [Shizuoka University, 836 Ohya, Suruga-ku Shizuoka 422-8529 (Japan)

    2016-12-15

    Highlights: • Influence of CuO particle size and diameter of reaction tubing on the tritium recovery was evaluated. • Reaction rate constant of tritium with CuO particle has been calculated by the combination of experimental results and a simulation code. • Dependence of reaction tubing length on tritium conversion ratio has been explored. - Abstract: Usage of CuO and water bubbler is one of the conventional and convenient methods for tritium recovery. In present work, influence of CuO particle size and diameter of reaction tubing on the tritium recovery was evaluated. Reaction rate constant of tritium with CuO particle has been calculated by the combination of experimental results and a simulation code. Then, these results were applied for exploring the dependence of reaction tubing length on tritium conversion ratio. The results showed that the surface area of CuO has a great influence on the oxidation rate constant. The frequency factor of the reaction would be approximately doubled by reducing the CuO particle size from 1.0 mm to 0.2 mm. Cross section of reaction tubing mainly affected on the duration of tritium at the temperature below 600 K. Reaction tubing with length of 1 m at temperature of 600 K would be suitable for keeping the tritium conversion ratio above 99.9%. The length of reaction tubing can be reduced by using the smaller CuO particle or increasing the CuO temperature.

  19. Apple fruit diameter and length estimation by using the thermal and sunshine hours approach and its application to the digital orchard management information system.

    Science.gov (United States)

    Li, Ming; Chen, Meixiang; Zhang, Yong; Fu, Chunxia; Xing, Bin; Li, Wenyong; Qian, Jianping; Li, Sha; Wang, Hui; Fan, Xiaodan; Yan, Yujing; Wang, Yan'an; Yang, Xinting

    2015-01-01

    In apple cultivation, simulation models may be used to monitor fruit size during the growth and development process to predict production levels and to optimize fruit quality. Here, Fuji apples cultivated in spindle-type systems were used as the model crop. Apple size was measured during the growing period at an interval of about 20 days after full bloom, with three weather stations being used to collect orchard temperature and solar radiation data at different sites. Furthermore, a 2-year dataset (2011 and 2012) of apple fruit size measurements were integrated according to the weather station deployment sites, in addition to the top two most important environment factors, thermal and sunshine hours, into the model. The apple fruit diameter and length were simulated using physiological development time (PDT), an indicator that combines important environment factors, such as temperature and photoperiod, as the driving variable. Compared to the model of calendar-based development time (CDT), an indicator counting the days that elapse after full bloom, we confirmed that the PDT model improved the estimation accuracy to within 0.2 cm for fruit diameter and 0.1 cm for fruit length in independent years using a similar data collection method in 2013. The PDT model was implemented to realize a web-based management information system for a digital orchard, and the digital system had been applied in Shandong Province, China since 2013. This system may be used to compute the dynamic curve of apple fruit size based on data obtained from a nearby weather station. This system may provide an important decision support for farmers using the website and short message service to optimize crop production and, hence, economic benefit.

  20. Automatic diameter control system applied to the laser heated pedestal growth technique

    Directory of Open Access Journals (Sweden)

    Andreeta M.R.B.

    2003-01-01

    Full Text Available We described an automatic diameter control system (ADC, for the laser heated pedestal growth technique, that reduces the diameter fluctuations in oxide fibers grown from unreacted and non-sinterized pedestals, to less than 2% of the average fiber diameter, and diminishes the average diameter fluctuation, over the entire length of the fiber, to less than 1%. The ADC apparatus is based on an artificial vision system that controls the pulling speed and the height of the molten zone within a precision of 30 mum. We also show that this system can be used for periodic in situ axial doping the fiber. Pure and Cr3+ doped LaAlO3 and pure LiNbO3 were usedas model materials.

  1. Estimating the board foot to cubic foot ratio

    Science.gov (United States)

    Steve P. Verrill; Victoria L. Herian; Henry N. Spelter

    2004-01-01

    Certain issues in recent softwood lumber trade negotiations have centered on the method for converting estimates of timber volumes reported in cubic meters to board feet. Such conversions depend on many factors; three of the most important of these are log length, diameter, and taper. Average log diameters vary by region and have declined in the western United States...

  2. Numerical Simulation of Flow and Heat Transfer in Structured Packed Beds with Smooth or Dimpled Spheres at Low Channel to Particle Diameter Ratio

    Directory of Open Access Journals (Sweden)

    Shiyang Li

    2018-04-01

    Full Text Available Packed beds are widely used in catalytic reactors or nuclear reactors. Reducing the pressure drop and improving the heat transfer performance of a packed bed is a common research aim. The dimpled structure has a complex influence on the flow and heat transfer characteristics. In the present study, the flow and heat transfer characteristics in structured packed beds with smooth or dimpled spheres are numerically investigated, where two different low channel to particle diameter ratios (N = 1.00 and N = 1.15 are considered. The pressure drop and the Nusselt number are obtained. The results show that, for N = 1.00, compared with the structured packed bed with smooth spheres, the structured packed bed with dimpled spheres has a lower pressure drop and little higher Nusselt number at 1500 < ReH < 14,000, exhibiting an improved overall heat transfer performance. However, for N = 1.15, the structured packed bed with dimpled spheres shows a much higher pressure drop, which dominantly affects the overall heat transfer performance, causing it to be weaker. Comparing the different channel to particle diameter ratios, we find that different configurations can result in: (i completely different drag reduction effect; and (ii relatively less influence on heat transfer enhancement.

  3. Relationship between the tensile strengths and diameters of human umbilical cords.

    Science.gov (United States)

    Fernando, D M G; Gamage, S M K; Ranmohottige, S; Weerakkody, I; Abeyruwan, H; Parakrama, H

    2018-05-01

    Mothers of alleged infanticides might claim that umbilical cord broke during precipitate delivery causing injuries detected on baby at autopsy. There is paucity of evidence regarding this possibility. The objective of the study was to determine relationship between tensile strength and diameter or weight per unit length of cord. Diameters and weights per unit length of fresh umbilical cords were determined. Tensile strengths were measured by Hounsfield Testing Machine. Relationship between tensile strength versus cord diameter and weight per unit length were analyzed. Of 122 cords, average tensile strength, diameter and weight per centimeter were 50.4 N, 7.73 mm and 6.87 g respectively. The tensile strengths were directly proportional to diameter. There was no association between tensile strength and weight per centimeter. Measurement of the diameter of cord is important during autopsy to predict tensile strength and thereby to presume whether cord could have broken by the weight of the baby. Copyright © 2018 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  4. Apple fruit diameter and length estimation by using the thermal and sunshine hours approach and its application to the digital orchard management information system.

    Directory of Open Access Journals (Sweden)

    Ming Li

    Full Text Available In apple cultivation, simulation models may be used to monitor fruit size during the growth and development process to predict production levels and to optimize fruit quality. Here, Fuji apples cultivated in spindle-type systems were used as the model crop. Apple size was measured during the growing period at an interval of about 20 days after full bloom, with three weather stations being used to collect orchard temperature and solar radiation data at different sites. Furthermore, a 2-year dataset (2011 and 2012 of apple fruit size measurements were integrated according to the weather station deployment sites, in addition to the top two most important environment factors, thermal and sunshine hours, into the model. The apple fruit diameter and length were simulated using physiological development time (PDT, an indicator that combines important environment factors, such as temperature and photoperiod, as the driving variable. Compared to the model of calendar-based development time (CDT, an indicator counting the days that elapse after full bloom, we confirmed that the PDT model improved the estimation accuracy to within 0.2 cm for fruit diameter and 0.1 cm for fruit length in independent years using a similar data collection method in 2013. The PDT model was implemented to realize a web-based management information system for a digital orchard, and the digital system had been applied in Shandong Province, China since 2013. This system may be used to compute the dynamic curve of apple fruit size based on data obtained from a nearby weather station. This system may provide an important decision support for farmers using the website and short message service to optimize crop production and, hence, economic benefit.

  5. Equations relating compacted and uncompacted live crown ratio for common tree species in the South

    Science.gov (United States)

    KaDonna C. Randolph

    2010-01-01

    Species-specific equations to predict uncompacted crown ratio (UNCR) from compacted live crown ratio (CCR), tree length, and stem diameter were developed for 24 species and 12 genera in the southern United States. Using data from the US Forest Service Forest Inventory and Analysis program, nonlinear regression was used to model UNCR with a logistic function. Model...

  6. The impact analysis of the connecting pipe length and diameter on the operation of a piston hybrid power machine of positive displacement with gas suction capacity

    Science.gov (United States)

    Shcherba, V. E.; Grigoriev, A. V.; Averyanov, G. S.; Surikov, V. I.; Vedruchenko, V. P.; Galdin, N. S.; Trukhanova, D. A.

    2017-08-01

    The article analyzes the impact of the connecting liquid pipe length and diameter on consumables and power characteristics of the piston hybrid power machine with gas suction capacity. The following operating characteristics of the machine were constructed and analyzed: the average height of the liquid column in the jacket space; instantaneous velocity and height of the liquid column in the jacket space; the relative height of the liquid column in the jacket space; volumetric efficiency; indicator isothermal efficiency; flowrate in the pump section; relative pressure losses during suction; relative flowrate. The dependence of the instantaneous pressure in the work space and the suction space of the compressor section on the rotation angle of the crankshaft is determined for different values of the length and diameter of the connecting pipeline.

  7. Relationship of the duke jeopardy score combined with minimal lumen diameter as assessed by computed tomography angiography to the hemodynamic relevance of coronary artery stenosis.

    Science.gov (United States)

    Yu, Mengmeng; Zhao, Yonghong; Li, Wenbin; Lu, Zhigang; Wei, Meng; Zhou, Wenxiao; Zhang, Jiayin

    2018-03-02

    To study the diagnostic performance of the ratio between the Duke jeopardy score (DJS) and the minimal lumen diameter (MLD) (DJS/MLD CT ratio) as assessed by coronary computed tomographic angiography (CTA) for differentiating functionally significant from non-significant coronary artery stenoses, with reference to invasive fractional flow reserve (FFR). Patients who underwent both coronary CTA and FFR measurement during invasive coronary angiography (ICA) within 2 weeks were retrospectively included in the study. Invasive FFR measurement was performed in patients with intermediate to severe coronary stenoseis. DJS/MLD CT ratio and anatomical parameters were recorded. Lesions with FFR ≤0.80 were considered to be functionally significant. One hundred and sixty-one patients with 175 lesions were included into the analysis. Diameter stenosis in CT, area stenosis, plaque burden, lesion length (LL), ICA-based stenosis degree, DJS, LL/MLD 4 ratio, DJS/MLA ratio as well as DJS/MLD ratio were all significantly different between hemodynamically significant and non-significant lesions (pvalue for DJS/MLD CT ratio to be 1.96 (area under curve = 0.863, 95 % confidence interval = 0.803-0.910), yielding a high diagnostic accuracy (86.9%, 152/175). In coronary artery stenoses detected by coronary CTA, the DJS/MLD ratio is able to predict hemodynamic relevance. Copyright © 2018 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  8. Changes in Cross-Sectional Area and Transverse Diameter of the Heart on Inspiratory and Expiratory Chest CT: Correlation with Changes in Lung Size and Influence on Cardiothoracic Ratio Measurement.

    Directory of Open Access Journals (Sweden)

    Hayato Tomita

    Full Text Available The aim of this study was to investigate physiological changes in cardiac area and diameters between inspiratory and expiratory chest computed tomography (CT, and to assess their correlation with lung size change and influence on cardiothoracic ratio (CTR measurements.The institutional review board of our institution approved this study, and informed consent was waived. Forty-three subjects underwent inspiratory and expiratory chest CT as part of routine clinical care. On both inspiratory and expiratory scans, lung volumes and maximum lung diameters (transverse and vertical directions were measured. The maximum cardiac cross-sectional area (CSA and the maximum transverse cardiac diameter were measured on both scans, and the CT-based CTR was calculated. Changes in the lung and cardiac measurements were expressed as the expiratory/inspiratory (E/I ratios. Comparisons between inspiratory and expiratory measurements were made by the Wilcoxon signed-rank test. Correlations between the E/I ratios of lung and heart measurements were evaluated by Spearman's rank correlation analysis.Cardiac CSA and transverse cardiac diameter was significantly larger on expiratory than on inspiratory CT (p < 0.0001. Significant negative correlations were found between the E/I ratios of these cardiac measurements and the E/I ratios of lung volume and vertical lung diameter (p < 0.01. CT-based CTR was significantly larger on expiration than on inspiration (p < 0.0001.Heart size on chest CT depends on the phase of ventilation, and is correlated with changes in lung volume and craniocaudal lung diameter. The CTR is also significantly influenced by ventilation.

  9. Normal ureteral diameter in infancy and childhood

    International Nuclear Information System (INIS)

    Hellstroem, M.; Hjaelmaas, K.; Jacobsson, B.; Jodal, U.; Oden, A.; Oestra Sjukhuset, Goeteborg; Oestra Sjukhuset, Goeteborg; Goeteborg Univ.

    1985-01-01

    Ureteral diameters were estimated on films from intravenous urography in 194 children (100 boys and 94 girls) aged 0-16 years. Children with signs of urinary tract infection, calculi, obstruction, duplication or malformation were excluded. Films obtained without abdominal compression were used for measurements, including only ureters visualized over 50 per cent of their lengths. A good correlation was demonstrated between ureteral diameter and age and between ureteral diameter and the length of a segment of the lumbar spine. The widest part of the ureter was most often located just above the crossing of the iliac vessels. The right ureter was slightly wider than the left one. No difference between boys and girls was noted. The results are in good agreement with those of others obtained at autopsy. Bearing in mind the possible physiologic variations, it would seem that measuring the ureteral diameter can be of value for a more objective differentiation between dilated and non-dilated ureters. (orig.)

  10. Tree Diamter Effects on Cost and Productivity of Cut-to-Length Systems

    Science.gov (United States)

    Matthew A. Holtzscher; Bobby L. Lanford

    1997-01-01

    Currently, there is a lack of economic information concerning cut-to-length harvesting systems. This study examined and measured the different costs of operating cut-to-length logging equipment over a range of average stand diameters at breast height. Three different cut-to-length logging systems were examined in this study. Systems included: 1) felier-buncher/manual/...

  11. Displacer Diameter Effect in Displacer Pulse Tube Refrigerator

    Science.gov (United States)

    Zhu, Shaowei

    2017-12-01

    Gas driving displacer pulse tube refrigerators are one of the work recovery type of pulse tube refrigerators whose theoretical efficiency is the same as Stirling refrigerators'. Its cooling power is from the displacement of the displacer. Displace diameter, rod diameter and pressure drop of the regenerator influence the displacement, which are investigated by numerical simulation. It is shown that the displacement ratio of the displacer over the piston is almost not affected by the displacer diameter at the same rod diameter ratio, or displacer with different diameters almost has the same performance.

  12. Lock-on characteristics behind two side-by-side cylinders of diameter ratio two at small gap ratio

    Science.gov (United States)

    Lee, Petry Y. R.; Lu, Wei-Ting; Chou, Shy-Tsin; Kuo, Cheng-Hsiung

    2012-10-01

    The lock-on characteristics, the detailed interactions and downstream evolutions of the wakes behind side-by-side cylinders of unequal diameter ( D/ d = 2), spaced by a gap ratio 0.75 ( G/ D = 0.75), are investigated at Reynolds number 600 by the dye flow visualization, laser Doppler anemometry (LDA) and particle image velocimeter (PIV) velocity measurements. The lock-on frequency bands are studied by LDA and PIV at Reynolds number 2,000. The D, d and G are the diameters of the large, the small cylinders and the net gap between two cylinders, respectively. Periodic excitations, in form of rotary oscillation about the cylinder center, are applied to the large cylinder with the same amplitude. It is found that while the large cylinder is excited, two lock-on frequency bands of the wake behind the large cylinder are detected. These two lock-on frequency bands correspond to the primary and the one-third sub-harmonic lock-on of the wake behind large cylinder, respectively. These two lock-on frequency bands distribute symmetrically about the fundamental and the third superharmonic of the natural shedding frequency behind a single cylinder at the same Reynolds number. The left-shifted frequency band (1.8 ≤ f e / f os ≤ 2.0) is not considered as a locked-on frequency band because the phase difference between two excitation frequencies across f e / f os = 2.0 vary significantly. While the wake behind the large cylinder is locked-on at f e /3 (or f os ), the gap flow becomes unbiased and the frequency of the wake behind small cylinder remains around the natural shedding frequency. Thus, the frequency band of 3.0 ≤ f e / f os ≤ 3.22 is also not locked-on because the phase difference in the narrow wake excited at f e / f os = 2.93 and 3.07 changes significantly. Note f e and f os denote the excitation frequency and the natural shedding frequency behind a single large cylinder, respectively.

  13. Lock-on characteristics behind two side-by-side cylinders of diameter ratio two at small gap ratio

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Petry Y.R.; Lu, Wei-Ting; Chou, Shy-Tsin; Kuo, Cheng-Hsiung [National Chung Hsing University, Department of Mechanical Engineering, Taichung (China)

    2012-10-15

    The lock-on characteristics, the detailed interactions and downstream evolutions of the wakes behind side-by-side cylinders of unequal diameter (D/d = 2), spaced by a gap ratio 0.75 (G/D = 0.75), are investigated at Reynolds number 600 by the dye flow visualization, laser Doppler anemometry (LDA) and particle image velocimeter (PIV) velocity measurements. The lock-on frequency bands are studied by LDA and PIV at Reynolds number 2,000. The D, d and G are the diameters of the large, the small cylinders and the net gap between two cylinders, respectively. Periodic excitations, in form of rotary oscillation about the cylinder center, are applied to the large cylinder with the same amplitude. It is found that while the large cylinder is excited, two lock-on frequency bands of the wake behind the large cylinder are detected. These two lock-on frequency bands correspond to the primary and the one-third sub-harmonic lock-on of the wake behind large cylinder, respectively. These two lock-on frequency bands distribute symmetrically about the fundamental and the third superharmonic of the natural shedding frequency behind a single cylinder at the same Reynolds number. The left-shifted frequency band (1.8 {<=} f{sub e} /f{sub os} {<=} 2.0) is not considered as a locked-on frequency band because the phase difference between two excitation frequencies across f{sub e} /f{sub os} = 2.0 vary significantly. While the wake behind the large cylinder is locked-on at f{sub e} /3 (or f{sub os}), the gap flow becomes unbiased and the frequency of the wake behind small cylinder remains around the natural shedding frequency. Thus, the frequency band of 3.0 {<=} f{sub e} /f{sub os} {<=} 3.22 is also not locked-on because the phase difference in the narrow wake excited at f{sub e} /f{sub os} = 2.93 and 3.07 changes significantly. Note f{sub e} and f{sub os} denote the excitation frequency and the natural shedding frequency behind a single large cylinder, respectively. (orig.)

  14. Synthesis of an ultradense forest of vertically aligned triple-walled carbon nanotubes of uniform diameter and length using hollow catalytic nanoparticles.

    Science.gov (United States)

    Baliyan, Ankur; Nakajima, Yoshikata; Fukuda, Takahiro; Uchida, Takashi; Hanajiri, Tatsuro; Maekawa, Toru

    2014-01-22

    It still remains a crucial challenge to actively control carbon nanotube (CNT) structure such as the alignment, area density, diameter, length, chirality, and number of walls. Here, we synthesize an ultradense forest of CNTs of a uniform internal diameter by the plasma-enhanced chemical vapor deposition (PECVD) method using hollow nanoparticles (HNPs) modified with ligand as a catalyst. The diameters of the HNPs and internal cavities in the HNPs are uniform. A monolayer of densely packed HNPs is self-assembled on a silicon substrate by spin coating. HNPs shrink via the collapse of the internal cavities and phase transition from iron oxide to metallic iron in hydrogen plasma during the PECVD process. Agglomeration of catalytic NPs is avoided on account of the shrinkage of the NPs and ligand attached to the NPs. Diffusion of NPs into the substrate, which would inactivate the growth of CNTs, is also avoided on account of the ligand. As a result, an ultradense forest of triple-walled CNTs of a uniform internal diameter is successfully synthesized. The area density of the grown CNTs is as high as 0.6 × 10(12) cm(-2). Finally, the activity of the catalytic NPs and the NP/carbon interactions during the growth process of CNTs are investigated and discussed. We believe that the present approach may make a great contribution to the development of an innovative synthetic method for CNTs with selective properties.

  15. Fruit production and branching density affect shoot and whole-tree wood to leaf biomass ratio in olive.

    Science.gov (United States)

    Rosati, Adolfo; Paoletti, Andrea; Al Hariri, Raeed; Famiani, Franco

    2018-02-14

    The amount of shoot stem (i.e., woody part of the shoot) dry matter per unit shoot leaf dry matter (i.e., the shoot wood to leaf biomass ratio) has been reported to be lower in short shoots than in long ones, and this is related to the greater and earlier ability of short shoots to export carbon. This is important in fruit trees, since the greater and earlier carbon export ability of shoots with a lower wood to leaf biomass ratio improves fruit production. This ratio may vary with cultivars, training systems or plant age, but no study has previously investigated the possible effect of fruit production. In this study on two olive cultivars (i.e., Arbequina, with low growth rate, and Frantoio, with high growth rate) subject to different fruit production treatments, we found that at increasing fruit production, shoot length and shoot wood to leaf biomass ratio were proportionally reduced in the new shoots growing at the same time as the fruit. Specifically, fruit production proportionally reduced total new-shoot biomass, length, leaf area and average shoot length. With decreasing shoot length, shoot diameter, stem mass, internode length, individual leaf area and shoot wood to leaf biomass ratio also decreased. This may be viewed as a plant strategy to better support fruit growth in the current year, given the greater and earlier ability of short shoots to export carbon. Moreover, at the whole-tree level, the percentage of total tree biomass production invested in leaves was closely correlated with branching density, which differed significantly across cultivars. By branching more, Arbequina concentrates more shoots (thus leaves) per unit of wood (trunk, branches and root) mass, decreasing wood to leaf biomass ratio at the whole-tree level. Therefore, while, at the shoot level, shoot length determines shoot wood to leaf biomass ratio, at the canopy level branching density is also an important determinant of whole-tree wood to leaf biomass ratio. Whole-tree wood to leaf

  16. A novel nitrite biosensor based on the direct electron transfer hemoglobin immobilized in the WO3 nanowires with high length–diameter ratio

    International Nuclear Information System (INIS)

    Liu, Hui; Duan, Congyue; Yang, Chenhui; Chen, Xianjin; Shen, Wanqiu; Zhu, Zhenfeng

    2015-01-01

    WO 3 nanowires (WO 3 NWs) with high length–diameter ratio have been synthesized through a simple synthetic route without any additive and then used to immobilize hemoglobin (Hb) to fabricate a mediator-free biosensor. The morphology and structure of WO 3 NWs were characterized by scanning electron microscopy, transmission electronic microscopy and X-ray diffraction. Spectroscopic and electrochemical results revealed that WO 3 NWs are an excellent immobilization matrix with biocompatibility for redox protein, affording good protein bioactivity and stability. Meanwhile, due to unique morphology and property of the WO 3 nanowires, the direct electron transfer of Hb is facilitated and the prepared biosensors displayed good performance for the detection of nitrite with a wide linear range of 1 to 4200 μM, as well as an extremely low detection limit of 0.28 μM. The WO 3 nanowires with high length–diameter ratio could be a promising matrix for the fabrication of mediator-free biosensors, and may find wide potential applications in environmental analysis and biomedical detection. - Highlights: • The WO 3 NWs with high length–diameter ratio have been synthesized. • The WO 3 NWs were used to immobilize Hb to fabricate a mediator-free biosensor. • The biosensor displays a wide linear range of 1–4200 μM for nitrite. • The biosensor exhibits an extremely low detection limit of 0.28 μM for nitrite

  17. Study on two phase flow characteristics in annular pulsed extraction column with different ratio of annular width to column diameter

    International Nuclear Information System (INIS)

    Qin Wei; Dai Youyuan; Wang Jiading

    1994-01-01

    Annular pulsed extraction column can successfully provide large throughput and can be made critically safe for fuel reprocessing. This investigation is to study the two phase flow characteristics in annular pulsed extraction column with four different annular width. 30% TBP (in kerosene)-water is used (water as continuous phase). Results show that modified Pratt correlation is valid under the experimental operation conditions for the annular pulsed extraction column. The characteristic velocity U K decreased with the increase of energy input and increased with the increase of the ratio of annular width to column diameter. Flooding velocity correlation is suggested. The deviation of the calculated values from the experimental data is within +20% for four annular width in a pulsed extraction column

  18. Morphometric Characteristics and Length-Weight Relationship of Russian Sturgeon Juveniles Fed with Different Ratio

    Directory of Open Access Journals (Sweden)

    Raluca Cristina ANDREI(GURIENCU

    2017-11-01

    Full Text Available The aim of this paper was to analyze some morphometric characteristics and the correlation between them for Russian sturgeon juveniles (Acipenser gueldenstaedtii reared in a recirculating aquaculture system fed at different fed with different ratio: 1% body weight (BW, 1.5% BW, 2% BW and ad libitum feeding (which was around 2.8% BW.Fish, with an average body mass around 248.194 ± 1.59 g. Following biometric measurements were made for each fish, including weight (W, total length (TL, standard length (SL, fork length (FL, maximum body depth (last depth of caudal peduncle, H; preanal distance (AD, predorsal distance (PD, length of head (C, preorbital distance (PO, length of pectoral fin (LPF, interorbital distance (ID, maximum width of head (MH, width of mouth (WM, width of the head at the level of the mouth (WHM. The obtained results showed significant differences between all morphometric measurements (p<0.05 for all the experimental variants, emphasizing that in the ad libitum feeding all morphometric measurements were significantly higher than in the other experimental variants. In order to highlight more eloquent these differences, were developed some linear regressions between the morphometric measurements and significant positive correlation (p<0.05 between dependent and independent variables were found.

  19. Evaluation of technology for large- and small-diameter boreholes to characterize crystalline rock

    International Nuclear Information System (INIS)

    1985-05-01

    Testing methods that have been used in large- and small-diameter boreholes (152 and 76 mm [6 and 3 in.]) were evaluated on their ability to characterize crystalline rocks. The methods evaluated included in-hole geomechanical, geophysical, and geohydrologic techniques and associated laboratory core tests; specific emphasis was on techniques that might be used in a field characterization program involving a small number of deep (up to 1500 m [5000 ft]) boreholes. Each technique was evaluated with regard to its effectiveness and limitations, applicability to the acquisition of data for anticipated rock conditions, and adequacy for assessing the required rock/hydrologic characteristics. Many pertinent case histories that helped to assess applicability were reviewed. A principal objective of the evaluations was to assess whether the techniques would be equally useful in both large- and small-diameter boreholes. Of the techniques evaluated, most are suitable for use in both large- and small-diameter boreholes. Borehole logging, hydrologic testing, and core-testing techniques provide suitable results in both borehole diameters. Geomechanical testing techniques provide suitable data in smaller diameter boreholes and have been designed for application at primarily shallow depths. The results of this study will be of use to the Office of Crystalline Repository Development (OCRD) in determining to what degree it is appropriate to use drilling, sampling, and testing techniques in small-diameter boreholes as opposed to large-diameter methods, while at the same time collecting adequate data for characterizing crystalline rock environments for potential use as a high-level radioactive waste repository. Additionally, further developmental work and specific testing techniques are recommended

  20. Development of a virtual probe tip with an application to high aspect ratio microscale features

    International Nuclear Information System (INIS)

    Bauza, Marcin B.; Hocken, Robert J.; Smith, Stuart T.; Woody, Shane C.

    2005-01-01

    Nondestructive measurement of microscale features remains a challenging metrology problem. For example, to assess a high aspect ratio small hole it is currently common to cut a cross section and measure the features of interest using an atomic force microscope, scanning probe microscope, or scanning electron microscope. Typically, these metrology tools may be suitable for surface finish measurement but often lack the capability for dimensional metrology. The aim of this article is to discuss the development of a high aspect-ratio microscale probe for measurement of microscale features. A 700:1 high aspect ratio probe shank is fabricated with a 7 μm diameter, and attached at one end to an oscillator. The oscillator produces a standing wave in the oscillating probe shank as opposed to conventional probes that use a microscale sphere on the end of a comparatively rigid shank. As a result of the standing wave formed in steady state vibration, the free end of the shank generates an amplitude of oscillation greater than the probe shank diameter. Thus, the probe does not require a spherical ball to serve as the contact point and simply uses the contact diameter of the free end of the vibrating shank. This methodology is referred to as a virtual probe tip. The virtual probe tip in conjunction with a nanopositioning scanner is used to measure surface profile measurements over traverse lengths of 130 μm. In this article, results from profiles of a 500 nm step height and a ruby sphere of diameter 1 mm are presented. Experiments in this article indicate the ability to repeatedly resolve surface features of less than 5 nm while maintaining bandwidths greater than 1 kHz. Furthermore, adhesion problems often encountered with micrometer scaled probes were not observed during profile measurements with this virtual probe

  1. Performance and emission characteristics of LPG powered four stroke SI engine under variable stroke length and compression ratio

    International Nuclear Information System (INIS)

    Ozcan, Hakan; Yamin, Jehad A.A.

    2008-01-01

    A computer simulation of a variable stroke length, LPG fuelled, four stroke, single cylinder, water cooled spark ignition engine was done. The engine capacity was varied by varying the stroke length of the engine, which also changed its compression ratio. The simulation model developed was verified with experimental results from the literature for both constant and variable stroke engines. The performance of the engine was simulated at each stroke length/compression ratio combination. The simulation results clearly indicate the advantages and utility of variable stroke engines in fuel economy and power issues. Using the variable stroke technique has significantly improved the engine's performance and emission characteristics within the range studied. The brake torque and power have registered an increase of about 7-54% at low speed and 7-57% at high speed relative to the original engine design and for all stroke lengths and engine speeds studied. The brake specific fuel consumption has registered variations from a reduction of about 6% to an increase of about 3% at low speed and from a reduction of about 6% to an increase of about 8% at high speed relative to the original engine design and for all stroke lengths and engine speeds studied. On the other hand, an increase of pollutants of about 0.65-2% occurred at low speed. Larger stroke lengths resulted in a reduction of the pollutants level of about 1.5% at higher speeds. At lower stroke lengths, on the other hand, an increase of about 2% occurred. Larger stroke lengths resulted in increased exhaust temperature and, hence, make the exhaust valve work under high temperature

  2. A novel nitrite biosensor based on the direct electron transfer hemoglobin immobilized in the WO{sub 3} nanowires with high length–diameter ratio

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Hui, E-mail: liuhui@sust.edu.cn; Duan, Congyue; Yang, Chenhui; Chen, Xianjin; Shen, Wanqiu; Zhu, Zhenfeng

    2015-08-01

    WO{sub 3} nanowires (WO{sub 3}NWs) with high length–diameter ratio have been synthesized through a simple synthetic route without any additive and then used to immobilize hemoglobin (Hb) to fabricate a mediator-free biosensor. The morphology and structure of WO{sub 3}NWs were characterized by scanning electron microscopy, transmission electronic microscopy and X-ray diffraction. Spectroscopic and electrochemical results revealed that WO{sub 3}NWs are an excellent immobilization matrix with biocompatibility for redox protein, affording good protein bioactivity and stability. Meanwhile, due to unique morphology and property of the WO{sub 3} nanowires, the direct electron transfer of Hb is facilitated and the prepared biosensors displayed good performance for the detection of nitrite with a wide linear range of 1 to 4200 μM, as well as an extremely low detection limit of 0.28 μM. The WO{sub 3} nanowires with high length–diameter ratio could be a promising matrix for the fabrication of mediator-free biosensors, and may find wide potential applications in environmental analysis and biomedical detection. - Highlights: • The WO{sub 3}NWs with high length–diameter ratio have been synthesized. • The WO{sub 3}NWs were used to immobilize Hb to fabricate a mediator-free biosensor. • The biosensor displays a wide linear range of 1–4200 μM for nitrite. • The biosensor exhibits an extremely low detection limit of 0.28 μM for nitrite.

  3. The effect of the expansion ratio on a turbulent non-Newtonian recirculating flow

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, A.S. [Departamento de Engenharia Quimica Instituto Superior de Engenharia do Porto (Portugal); Pinho, F.T. [Centro de Estudos de Fenomenos de Transporte, DEMEGI, Faculdade de Engenharia, Universidade do Porto (Portugal)

    2002-04-01

    Measurements of the mean and turbulent flow characteristics of shear-thinning moderately elastic 0.1% and 0.2% xanthan gum aqueous solutions were carried out in a sudden expansion having a diameter ratio of 2. The inlet flow was turbulent and fully developed, and the results were compared with data for water in the same geometry and with previous published Newtonian and non-Newtonian data in a smaller expansion of diameter ratio equal to 1.538. An increase in expansion ratio led to an increase in the recirculation length and in the axial normal Reynolds stress at identical normalised locations, but the difference between Newtonian and non-Newtonian characteristics was less intense than in the smaller expansion. An extensive comparison of mean and turbulent flow characteristics was carried out in order to understand the variation of flow features. (orig.)

  4. The variation of the reactivity with the number, diameter and length of the control rods in a heavy water natural uranium reactor

    Energy Technology Data Exchange (ETDEWEB)

    McCriric, H

    1958-05-15

    Starting with the known reactor constants for a heavy water moderated reactor with reflector and a given number of control rods of a certain size, the reactivity equivalence of the control rods is calculated. The calculation is given in detail. The number, length and diameter of the control rods is then varied and the effect of these parameters on the reactivity is shown graphically. Flux plots are also given for the reactor with and without control rods.

  5. Nineteen-Foot Diameter Explosively Driven Blast Simulator; TOPICAL

    International Nuclear Information System (INIS)

    VIGIL, MANUEL G.

    2001-01-01

    This report describes the 19-foot diameter blast tunnel at Sandia National Laboratories. The blast tunnel configuration consists of a 6 foot diameter by 200 foot long shock tube, a 6 foot diameter to 19 foot diameter conical expansion section that is 40 feet long, and a 19 foot diameter test section that is 65 feet long. Therefore, the total blast tunnel length is 305 feet. The development of this 19-foot diameter blast tunnel is presented. The small scale research test results using 4 inch by 8 inch diameter and 2 foot by 6 foot diameter shock tube facilities are included. Analytically predicted parameters are compared to experimentally measured blast tunnel parameters in this report. The blast tunnel parameters include distance, time, static, overpressure, stagnation pressure, dynamic pressure, reflected pressure, shock Mach number, flow Mach number, shock velocity, flow velocity, impulse, flow duration, etc. Shadowgraphs of the shock wave are included for the three different size blast tunnels

  6. The effects of cavity length on nest size, sex ratio and mortality of Centris (Heterocentris) analis (Hymenoptera, Apidae, Centridini)

    OpenAIRE

    Alonso , Juliana; Silva , Janaina; Garófalo , Carlos

    2012-01-01

    International audience; This study investigated the effects of different cavity lengths in trap-nests on the number of cells constructed per nest, sex ratio and mortality of offspring of Centris analis at three sites in Ribeirão Preto, São Paulo, Brazil. Cavity length did not affect the occupation rates of the trap-nests, with the exception of a preference for the shortest trap-nests found at one site. The number of cells per nest increased with trap-nest length. Cavity length affected neithe...

  7. Reference interval for the disc-macula distance to disc diameter ratio in a large population of healthy Japanese adults

    Science.gov (United States)

    Sato, Ken-ichi

    2017-01-01

    Abstract This study presents the calculated reference interval for the disc-to-macula distance to disc diameter ratio (DM:DD) based on a large population of healthy Japanese adults. A total of 308 consecutive, healthy Japanese adults were examined in this prospective observational study. Eighteen subjects were also excluded because of poor quality of the fundus photograph of one or both eyes; 290 (161 men and 129 women) were included in this study. For each subject, a color fundus photograph of one eye, either the right or left, was randomly selected and used for analysis. On the photograph, the distances between the fovea and the nearest temporal margin of the optic disc (Dft), and the two kinds of disc diameters (D1 and D2), which bisected at right angles and one of which was directed to the fovea (D1), were measured. DM:DD was estimated using the formula: (2Dft + D1)/(D1 + D2). The mean ± standard deviation of DM:DD was 2.91 ± 0.49 for men and 2.96 ± 0.54 for women; there was no sex difference (P = .78, Mann–Whitney U test). Also, almost no relationship was found between DM:DD and age (ρ = −.12, P = .04, Spearman's rank correlation coefficient). The data did not fit a normal distribution (P < .001, Kolmogorov–Smirnov test). The estimated reference interval for DM:DD corresponding to the 2.5th and 97.5th percentiles was 2.12 to 4.18. Using a nonparametric approach, the reference interval for DM:DD of a large population of healthy Japanese adults was calculated to be 2.12 to 4.18, regardless of age or sex. PMID:28403107

  8. Automated detection and classification of major retinal vessels for determination of diameter ratio of arteries and veins

    Science.gov (United States)

    Muramatsu, Chisako; Hatanaka, Yuji; Iwase, Tatsuhiko; Hara, Takeshi; Fujita, Hiroshi

    2010-03-01

    Abnormalities of retinal vasculatures can indicate health conditions in the body, such as the high blood pressure and diabetes. Providing automatically determined width ratio of arteries and veins (A/V ratio) on retinal fundus images may help physicians in the diagnosis of hypertensive retinopathy, which may cause blindness. The purpose of this study was to detect major retinal vessels and classify them into arteries and veins for the determination of A/V ratio. Images used in this study were obtained from DRIVE database, which consists of 20 cases each for training and testing vessel detection algorithms. Starting with the reference standard of vasculature segmentation provided in the database, major arteries and veins each in the upper and lower temporal regions were manually selected for establishing the gold standard. We applied the black top-hat transformation and double-ring filter to detect retinal blood vessels. From the extracted vessels, large vessels extending from the optic disc to temporal regions were selected as target vessels for calculation of A/V ratio. Image features were extracted from the vessel segments from quarter-disc to one disc diameter from the edge of optic discs. The target segments in the training cases were classified into arteries and veins by using the linear discriminant analysis, and the selected parameters were applied to those in the test cases. Out of 40 pairs, 30 pairs (75%) of arteries and veins in the 20 test cases were correctly classified. The result can be used for the automated calculation of A/V ratio.

  9. Diameter Control and Photoluminescence of ZnO Nanorods from Trialkylamines

    Directory of Open Access Journals (Sweden)

    Tamar Andelman

    2007-01-01

    Full Text Available A novel solution method to control the diameter of ZnO nanorods is reported. Small diameter (2-3 nm nanorods were synthesized from trihexylamine, and large diameter (50–80 nm nanorods were synthesized by increasing the alkyl chain length to tridodecylamine. The defect (green emission of the photoluminescence (PL spectra of the nanorods varies with diameter, and can thus be controlled by the diameter control. The small ZnO nanorods have strong green emission, while the large diameter nanorods exhibit a remarkably suppressed green band. We show that this observation supports surface oxygen vacancies as the defect that gives rise to the green emission.

  10. Length-scale and strain rate-dependent mechanism of defect formation and fracture in carbon nanotubes under tensile loading

    Energy Technology Data Exchange (ETDEWEB)

    Javvaji, Brahmanandam [Indian Institute of Science, Department of Aerospace Engineering (India); Raha, S. [Indian Institute of Science, Department of Computational and Data Sciences (India); Mahapatra, D. Roy, E-mail: droymahapatra@aero.iisc.ernet.in [Indian Institute of Science, Department of Aerospace Engineering (India)

    2017-02-15

    Electromagnetic and thermo-mechanical forces play a major role in nanotube-based materials and devices. Under high-energy electron transport or high current densities, carbon nanotubes fail via sequential fracture. The failure sequence is governed by certain length scale and flow of current. We report a unified phenomenological model derived from molecular dynamic simulation data, which successfully captures the important physics of the complex failure process. Length-scale and strain rate-dependent defect nucleation, growth, and fracture in single-walled carbon nanotubes with diameters in the range of 0.47 to 2.03 nm and length which is about 6.17 to 26.45 nm are simulated. Nanotubes with long length and small diameter show brittle fracture, while those with short length and large diameter show transition from ductile to brittle fracture. In short nanotubes with small diameters, we observe several structural transitions like Stone-Wales defect initiation, its propagation to larger void nucleation, formation of multiple chains of atoms, conversion to monatomic chain of atoms, and finally complete fracture of the carbon nanotube. Hybridization state of carbon-carbon bonds near the end cap evolves, leading to the formation of monatomic chain in short nanotubes with small diameter. Transition from ductile to brittle fracture is also observed when strain rate exceeds a critical value. A generalized analytical model of failure is established, which correlates the defect energy during the formation of atomic chain with aspect ratio of the nanotube and strain rate. Variation in the mechanical properties such as elastic modulus, tensile strength, and fracture strain with the size and strain rate shows important implications in mitigating force fields and ways to enhance the life of electronic devices and nanomaterial conversion via fracture in manufacturing.

  11. Inferring diameters of spheres and cylinders using interstitial water.

    Science.gov (United States)

    Herrera, Sheryl L; Mercredi, Morgan E; Buist, Richard; Martin, Melanie

    2018-06-04

    Most early methods to infer axon diameter distributions using magnetic resonance imaging (MRI) used single diffusion encoding sequences such as pulsed gradient spin echo (SE) and are thus sensitive to axons of diameters > 5 μm. We previously simulated oscillating gradient (OG) SE sequences for diffusion spectroscopy to study smaller axons including the majority constituting cortical connections. That study suggested the model of constant extra-axonal diffusion breaks down at OG accessible frequencies. In this study we present data from phantoms to test a time-varying interstitial apparent diffusion coefficient. Diffusion spectra were measured in four samples from water packed around beads of diameters 3, 6 and 10 μm; and 151 μm diameter tubes. Surface-to-volume ratios, and diameters were inferred. The bead pore radii estimates were 0.60±0.08 μm, 0.54±0.06 μm and 1.0±0.1 μm corresponding to bead diameters ranging from 2.9±0.4 μm to 5.3±0.7 μm, 2.6±0.3 μm to 4.8±0.6 μm, and 4.9±0.7 μm to 9±1 μm. The tube surface-to-volume ratio estimate was 0.06±0.02 μm -1 corresponding to a tube diameter of 180±70 μm. Interstitial models with OG inferred 3-10 μm bead diameters from 0.54±0.06 μm to 1.0±0.1 μm pore radii and 151 μm tube diameters from 0.06±0.02 μm -1 surface-to-volume ratios.

  12. Centrifuge modelling of large diameter pile in sand subject to lateral loading

    DEFF Research Database (Denmark)

    Leth, Caspar Thrane

    and cyclic behaviour of large diameter rigid piles in dry sand by use of physical modelling. The physical modelling has been carried out at Department of Civil Engineering at the Danish Technical University (DTU.BYG), in the period from 2005 to 2009. The main centrifuge facilities, and especially...... the equipment for lateral load tests were at the start of the research in 2005 outdated and a major part of the work with the geotechnical centrifuge included renovation and upgrading of the facilities. The research with respect to testing of large diameter piles included:  Construction of equipment...... with embedment lengths of 6, 8 and 10 times the diameter. The tests have been carried out with a load eccentricity of 2.5 m to 6.5 m above the sand surface. The present report includes a description of the centrifuge facilities, applied test procedure and equipment along with presentation of the obtained results....

  13. Diameter dependent failure current density of gold nanowires

    International Nuclear Information System (INIS)

    Karim, S; Maaz, K; Ali, G; Ensinger, W

    2009-01-01

    Failure current density of single gold nanowires is investigated in this paper. Single wires with diameters ranging from 80 to 720 nm and length 30 μm were electrochemically deposited in ion track-etched single-pore polycarbonate membranes. The maximum current density was investigated while keeping the wires embedded in the polymer matrix and ramping up the current until failure occurred. The current density is found to increase with diminishing diameter and the wires with a diameter of 80 nm withstand 1.2 x 10 12 A m -2 before undergoing failure. Possible reasons for these results are discussed in this paper.

  14. Estimation of intrathoracic arterial diameter by means of computed tomographic angiography in Hispaniolan Amazon parrots.

    Science.gov (United States)

    Beaufrère, Hugues; Rodriguez, Daniel; Pariaut, Romain; Gaschen Dvm, Lorrie; Schnellbacher, Rodney; Nevarez, Javier G; Tully, Thomas N

    2011-02-01

    To establish a computed tomography (CT)-angiography protocol and measure the diameters of major arteries in parrots. 13 Hispaniolan Amazon parrots (Amazona ventralis). 16-slice CT scanning was used to measure the apparent diameter of the ascending aorta, abdominal aorta, pulmonary arteries, and brachiocephalic trunk. Before scanning, all birds underwent ECG and echocardiographic assessment and were considered free of detectable cardiovascular diseases. Each bird was anesthetized, and a precontrast helical CT scan was performed. Peak aortic enhancement was established with a test bolus technique via dynamic axial CT scan over a predetermined single slice. An additional bolus of contrast medium was then injected, and a helical CT-angiography scan was performed immediately afterward. Arterial diameter measurements were obtained by 2 observers via various windows before and after injection, and intra- and interobserver agreement was assessed. Reference limits were determined for arterial diameter measurements before and after contrast medium administration in pulmonary, mediastinal, and manual angiography windows. Ratios of vertebral body diameter to keel length were also calculated. Intraobserver agreement was high (concordance correlation coefficients ≥ 0.95); interobserver agreement was medium to high (intraclass correlation coefficients ≥ 0.65). CT-angiography was safe and is of potential diagnostic value in parrots. We recommend performing the angiography immediately after IV injection of 3 mL of iohexol/kg. Arterial diameter measurements at the described locations were reliable.

  15. The role of B/D ratio and A/D ratio to defferentiate malignancy from benignancy in distal extrahepatic bile duct obstruction

    International Nuclear Information System (INIS)

    Rhim, Hyun Chul; Baek, JUng Hwan; Jeon, Eui Yong; Koh, Byung Hee; Cho, On Koo; Kim, Young Hwan

    1994-01-01

    To determine wheter bilirubin/extrahepatic bile duct diameter ratio(B/D ratio) or alkalinephosphatase/extrahepatic bile duct diameter ratio (A/D ratio) can be used to differentiate malignant from benigndisease in distal extrahepatic bile duct obstruction during ultrasonographic examination. We retrospectively reviewed the sonograms and laboratory data of 100 patients with obstructive jaundice (benign : n=50, malignant: : n=50). The diagnosis was confirmed either surgically (n=66) or clinically (n=34). The B/D ratio and A/D radio were calculated by means of dividing total bilirubin (mg/dl) and alkaline phosphatase (I.U.)respectively by maximum extrahepatic bile duct diameter(mm) on ultrasonogram. Significant difference in B/D ratio was found between the benignancy (0.28+0.25) and malignancy (0.98+0.84) groups (P<0.001). Significant difference in A/D ratio was also found between the benignancy (15.00+10.22) and malignancy (32.44+30.28) groups(P<0.001) Accuracies to predict malignancy according to criteria of B/D and A/D ratios were less than 75% and 65%respectively. On the other hand, the positive predictive value and specificity were relatively high. The B/D ratio and A/D ratio calculated from ultrasonograms can be used as a valuable screening index todifferentiate malignancy from benignacy in patients with distal extrahepatic bile duct obstruction, especially when the sonography is difficult because of the interposition of bowel gas or obesity

  16. Metal halide arc discharge lamp having short arc length

    Science.gov (United States)

    Muzeroll, Martin E. (Inventor)

    1994-01-01

    A metal halide arc discharge lamp includes a sealed light-transmissive outer jacket, a light-transmissive shroud located within the outer jacket and an arc tube assembly located within the shroud. The arc tube assembly includes an arc tube, electrodes mounted within the arc tube and a fill material for supporting an arc discharge. The electrodes have a spacing such that an electric field in a range of about 60 to 95 volts per centimeter is established between the electrodes. The diameter of the arc tube and the spacing of the electrodes are selected to provide an arc having an arc diameter to arc length ratio in a range of about 1.6 to 1.8. The fill material includes mercury, sodium iodide, scandium tri-iodide and a rare gas, and may include lithium iodide. The lamp exhibits a high color rendering index, high lumen output and high color temperature.

  17. Economic feasibility of products from inland West small-diameter timber

    Science.gov (United States)

    Spelter Henry; Rong Wang; Peter Ince

    1996-01-01

    A large part of the forests located in the Rocky Mountain region of the U.S. West (inland West) is characterized by densely packed, small-diameter stands. The purpose of this study was to examine the economic feasibility of using small-diameter material from this resource to manufacture various wood products: oriented strandboard (OSB), stud lumber, random-length...

  18. Experimental analysis of heat transfer between a heated wire and a rarefied gas in an annular gap with high diameter ratio

    International Nuclear Information System (INIS)

    Chalabi, H; Lorenzini, M; Morini, G L; Buchina, O; Valougeorgis, D; Saraceno, L

    2012-01-01

    In this paper a first experimental attempt is performed to measure heat conduction through rarefied air at rest contained between two concentric cylinders. The heat transfer between a heated platinum wire having a diameter (d) of 0.15 mm, disposed along the axis of a cylindrical shell in stainless steel having an inner diameter (D) of 100 mm, and a surrounded rarefied gas has been studied experimentally and numerically. The ratio between the outer and inner diameter of the annular region filled by the gas is large (D/d=667). In the annular region filled with air the pressure was varied by using a vacuum pump from atmospheric value down to 10 −3 mbar. Temperature differences between the wire and the external stainless steel wall in the range 50-125 K were imposed and the heat power transferred from the wire to the surround was measured as a function of the gas pressure starting from air at atmospheric conditions down to 10 −3 mbar. The experimental results obtained in these tests were compared with the numerical results obtained by using the linear and nonlinear Shakhov kinetic models.

  19. Co-existence of COPD and bronchiectasis: a risk factor for a high ratio of main pulmonary artery to aorta diameter (PA:A from computed tomography in COPD patients

    Directory of Open Access Journals (Sweden)

    Dou S

    2018-02-01

    Full Text Available Shuang Dou,1 Chunyan Zheng,1 Xiuli Ji,2 Wei Wang,1 Mengshuang Xie,1 Liwei Cui,1 Wei Xiao1 1Department of Pulmonary Medicine, Qilu Hospital, Shandong University, Jinan, People’s Republic of China; 2Department of Pulmonary Disease, Jinan Traditional Chinese Medicine Hospital, Jinan, People’s Republic of China Background: Pulmonary vascular disease, especially pulmonary hypertension, is an important complication of COPD. Bronchiectasis is considered not only a comorbidity of COPD, but also a risk factor for vascular diseases. The main pulmonary artery to aorta diameter ratio (PA:A ratio has been found to be a reliable indicator of pulmonary vascular disease. It is hypothesized that the co-existence of COPD and bronchiectasis may be associated with relative pulmonary artery enlargement (PA:A ratio >1.Methods: This retrospective study enrolled COPD patients from 2012 through 2016. Demographic and clinical data were collected. Bhalla score was used to determine the severity of bronchiectasis. Patient characteristics were analyzed in two ways: the high (PA:A >1 and low (PA:A ≤1 ratio groups; and COPD with and without bronchiectasis groups. Logistic regression analysis was used to assess risk factors for high PA:A ratios.Results: In this study, 480 COPD patients were included, of whom 168 had radiographic bronchiectasis. Patients with pulmonary artery enlargement presented with poorer nutrition (albumin, 35.6±5.1 vs 38.3±4.9, P<0.001, lower oxygen partial pressure (74.4±34.5 vs 81.3±25.4, P<0.001, more severe airflow obstruction (FEV1.0, 0.9±0.5 vs 1.1±0.6, P=0.004, and a higher frequency of bronchiectasis (60% vs 28.8%, P<0.001 than patients in the low ratio group. Patients with both COPD and bronchiectasis had higher levels of systemic inflammation (erythrocyte sedimentation rate, P<0.001 and fibrinogen, P=0.006 and PA:A ratios (P<0.001. A higher PA:A ratio was significantly closely correlated with a higher Bhalla score (r=0.412, P<0

  20. Controlled growth of well-aligned carbon nanotubes with large diameters

    Science.gov (United States)

    Wang, Xianbao; Liu, Yunqi; Zhu, Daoben

    2001-06-01

    Well-aligned carbon nanotubes (CNTs) with large diameters (25-200 nm) were synthesized by pyrolysis of iron(II) phthalocyanine. The outer diameter up to 218.5 nm and the length of the well-aligned CNTs can be systematically controlled by varying the growth time. A tube-in-tube nano-structure with large and small diameters of 176 and 16.7 nm, respectively, was found. The grain sizes of the iron catalyst play an important role in controlling the CNT diameters. These results are of great importance to design new aligned CNT-based electron field emitters in the potential application of panel displays.

  1. On-line ultrasonic inside-diameter control system for Zircaloy

    International Nuclear Information System (INIS)

    Tanaka, Y.; Fujii, N.; Komatsu, M.; Kubota, H.

    1984-01-01

    An ultrasonic inside-diameter (ID) control system was used during the final etching process for producing Zircaloy nuclear fuel cladding tubes. This results in establishing automatic inside-diameter control during etching with an automatic etching system. In this system, the inside-diameter at the center point in the length of each tube is continuously measured with the ultrasonic inside-diameter measuring equipment during the etching process and the etching is automatically stopped by a signal from the control equipment when the inside-diameter reaches the target value. This made the final etching process economical and suitable for large-scale production, having an equal or better level at the inside-diameter of tubes etched with this system than those made by a process controlled by an air-micrometer

  2. Cycle length and COD/N ratio determine properties of aerobic granules treating high-nitrogen wastewater.

    Science.gov (United States)

    Cydzik-Kwiatkowska, Agnieszka; Bernat, Katarzyna; Zielińska, Magdalena; Wojnowska-Baryła, Irena

    2014-07-01

    Aerobic granule characteristic in sequencing batch reactors treating high-nitrogen digester supernatant was investigated at cycle lengths (t) of 6, 8 and 12 h with the COD/N ratios in the influent of 4.5 and 2.3. The biomass production (Y obs) correlated with the extracellular polymeric substances (EPS) in grams per COD removed. Denitrification efficiency significantly decreased as the amount of EPS in biomass increased, suggesting that organic assimilation in EPS hampers nitrogen removal. Granule hydrophobicity was highest at t of 8 h; the t has to be long enough to remove pollutants, but not so long that excessive biomass starvation causes extracellular protein consumption that decreases hydrophobicity. At a given t, reducing the COD/N ratio improved hydrophobicity that stimulates cell aggregation. At t of 6 h and the COD/N ratio of 2.3, the dominance of 0.5-1.0 mm granules favored simultaneous nitrification and denitrification and resulted in the highest nitrogen removal.

  3. Effects of successive tracheal resection and anastomosis on tracheal diameter and position of lobar bronchi in dogs.

    Science.gov (United States)

    de Mello Souza, Carlos Henrique; Reinero, Carol R

    2016-06-01

    OBJECTIVE To evaluate the effects of successive large-segment tracheal resection and anastomosis on tracheal diameter and position of lobar bronchi in dogs. ANIMALS 5 adult Beagles. PROCEDURES Right lateral radiographs were obtained for all dogs and used to measure tracheal length. Dogs were then euthanized, and successive segmental tracheal resections (intervals of 10% from 20% to 50% of the tracheal length), each of which was followed by anastomosis, were performed in each cadaver. Tracheobronchoscopy was performed before the first tracheal resection and after each of the anastomoses to evaluate tracheal diameter and changes in position of lobar bronchi. RESULTS Tracheal diameter was minimally affected by resections up to 50% of the tracheal length. Diameter of the trachea and position of bronchi were not affected by resection of 20% of the tracheal length. Changes in the position of various lobar bronchi were detected after resection of 30% of the tracheal length. CONCLUSIONS AND CLINCIAL RELEVANCE In this study, tracheal resections of 20% of the tracheal length were accommodated, possibly as a result of stretching of the annular ligament. Resections of ≥ 30% of the tracheal length altered the position of lobar bronchi. Clinical effects, if any, attributable to these changes in bronchial position remain to be elucidated.

  4. Effect of shoulder to pin ratio on magnesium alloy Friction Stir Welding

    Science.gov (United States)

    Othman, N. H.; Ishak, M.; Shah, L. H.

    2017-09-01

    This study focuses on the effect of shoulder to pin diameter ratio on friction stir welding of magnesium alloy AZ31. Two pieces of AZ31 alloy with thickness of 2 mm were friction stir welded by using conventional milling machine. The shoulder to pin diameter ratio used in this experiment are 2.25, 2.5, 2.75, 3, 3.33, 3.66, 4.5, 5 and 5.5. The rotational speed and welding speed used in this study are 1000 rpm and 100 mm/min, respectively. Microstructure observation of welded area was studied by using optical microscope. Equiaxed grains were observed at the TMAZ and stir zone indicating fully plastic deformation. The grain size of stir zone increased with decreasing shoulder to pin ratio from ratio 3.33 to 5.5 due to higher heat input. It is observed that, surface galling and faying surface defect is produced when excessive heat input is applied. To evaluate the mechanical properties of this specimen, tensile test was used in this study. Shoulder to pin ratio 5.5 shows lowest tensile strength while shoulder to pin diameter ratio 3.33 shows highest tensile strength with weld efficiency 91 % from based metal.

  5. Advantages and risks in increasing cyclone separator length

    NARCIS (Netherlands)

    Hoffmann, AC; de Groot, M; Peng, W; Dries, HWA; Kater, J

    The effect of cyclone length on separation efficiency and pressure drop has been investigated experimentally and theoretically by varying the length of the cylindrical segment of a cylinder-on-cone cyclone. Experimental results based on cyclone lengths from 2.65 to 6.15 cyclone diameters showed a

  6. The effect of nozzle diameter, injection pressure and ambient temperature on spray characteristics in diesel engine

    Science.gov (United States)

    Rhaodah Andsaler, Adiba; Khalid, Amir; Sharifhatul Adila Abdullah, Nor; Sapit, Azwan; Jaat, Norrizam

    2017-04-01

    Mixture formation of the ignition process is a key element in the diesel combustion as it influences the combustion process and exhaust emission. Aim of this study is to elucidate the effects of nozzle diameter, injection pressure and ambient temperature to the formation of spray. This study investigated diesel formation spray using Computational Fluid Dynamics. Multiphase volume of fluid (VOF) behaviour in the chamber are determined by means of transient simulation, Eulerian of two phases is used for implementation of mixing fuel and air. The detail behaviour of spray droplet diameter, spray penetration and spray breakup length was visualised using the ANSYS 16.1. This simulation was done in different nozzle diameter 0.12 mm and 0.2 mm performed at the ambient temperature 500 K and 700 K with different injection pressure 40 MPa, 70 MPa and 140 MPa. Results show that high pressure influence droplet diameter become smaller and the penetration length longer with the high injection pressure apply. Smaller nozzle diameter gives a shorter length of the breakup. It is necessary for nozzle diameter and ambient temperature condition to improve the formation of spray. High injection pressure is most effective in improvement of formation spray under higher ambient temperature and smaller nozzle diameter.

  7. Solar variability observed through changes in solar figure and mean diameter

    International Nuclear Information System (INIS)

    Hill, H.A.

    1985-01-01

    A program to monitor solar luminosity variations through diameter measurements has been operation at SCLERA since 1981. The solar diameter is currently measured at multiple angles from the equator. Measurements at these different angles have the advantage that, not only can the solar oblateness be accurately measured, but, also, systematic errors, introduced by atmospheric refraction, can be reduced to a minimum. The primary emphasis during the last year has been on data analysis and interpretation. An extension of theoretical work relevant to the relationship between the solar diameter and luminosity for long-period oscillations has been extended to include 160 min period oscillations, and several tests have been completed. An absolute calibration system for the telescope field has been constructed and is being tested. A review of this work is presented

  8. Influence of time off feed on broiler viscera weight, diameter, and shear.

    Science.gov (United States)

    Buhr, R J; Northcutt, J K; Lyon, C E; Rowland, G N

    1998-05-01

    The influence of time off feed on broiler viscera weight, intestinal diameter, and shear was studied by subjecting market-age male broilers (42, 44, or 48 d) to incremental feed withdrawal periods (0, 6, 12, 18, or 24 h). Body weight was determined prior to feed withdrawal and at the time of processing. After slaughter, scalding, and defeathering, the abdominal cavity was opened. Diameter and shear of the proventriculus-ventriculus junction, jejunum, and ileum segments were measured, as were gallbladder length and width. Thoracic and abdominal viscera, liver, and ventriculus weights were determined, and liver surface color was measured. Percentage body weight loss increased with longer feed withdrawal periods, as viscera, liver, and ventriculus weights decreased. Gallbladder length increased with time off feed, whereas its width did not change. Diameter of the proventriculus-ventriculus junction, jejunum, and ileum decreased with longer feed withdrawal periods. Shear values for the proventriculus-ventriculus junction, jejunum, and ileum were not influenced by time off feed. Positive correlations (P 0.4) between viscera weight and intestinal diameter were detected. Correlations between all measured parameters and shear values were not significant. Liver color measurements indicated that longer feed withdrawal periods resulted in significant linear decreases in L* (lightness), +a* (redness), and +b* (yellowness). Longer feed withdrawal periods decreased viscera weight and intestinal diameter, which would lower the potential for cutting the intestine during automated evisceration. However, the resulting greater gallbladder length (5 mm) would increase the possibility of bile contamination during evisceration.

  9. Correlation between cup-to-disc ratio and cup/retrobulbar optic nerve diameter proportion assessed by high-resolution ultrasound in glaucomatous eyes

    Directory of Open Access Journals (Sweden)

    Wilian Silva Queiroz

    2013-10-01

    Full Text Available PURPOSE: To investigate the correlation between the measurements of the cup/retrobulbar optic nerve diameter (C/OND proportion obtained by high-resolution 20-MHz B-mode ultrasound (US and those of the cup/disc ratio (C/D obtained by fundus biomicroscopy (BIO and optical coherence tomography (OCT. METHODS: Thirty eyes of 15 glaucomatous patients with any C/D proportion were studied. All patients underwent examination of the vertical C/D by BIO with a 78D lens and time-domain OCT analysis, as well as the vertical C/OND proportion using 20-MHz US measurements. All data were analyzed by correlation and agreement tests. RESULTS: The Spearman test showed a strong correlation between C/D results obtained by BIO and the measurements of C/OND (US (r=0.788, p<0.0001, and with C/D obtained by OCT (r=0.8529, p<0.0001. However, comparison of C/D results obtained with OCT to those obtained by with C/OND (US showed only a moderate correlation (r=0.6727, p<0.0001. Bland-Altman analysis did not show good agreement between C/D (BIO and C/OND (US. CONCLUSIONS: The results demonstrate that B-mode ultrasound examination with a 20 MHz probe can be a good additional method for the evaluation of the C/D ratio in glaucomatous patients, and may be considered as an alternative gross tool in glaucomatous patients with optic media opacities.

  10. Changing the Diameter of a Viewing Tube

    Science.gov (United States)

    Obara, Samuel

    2009-01-01

    This article is about the students' investigation about the relationship between the diameter of the view tubes (x) of constant lengths and the viewable vertical distance (y) on the wall while keeping the perpendicular distance from the eyeball to the wall constant. The students collected data and used and represented it in tabular and graphical…

  11. Combined experimental and computational investigation of the cavitating flow in an orifice plate with special emphasis on surrogate-based optimization method

    International Nuclear Information System (INIS)

    Li, XianLin; Huang, Biao; Chen, Tairan; Liu, Ying; Qiu, Si Cong; Zhao, Jing

    2017-01-01

    We investigated the influence of geometrical parameters of the orifice plate on the cavitation structures, and optimized these parameters by using a surrogate-based model with special emphasis on the concentration of hydroxyl radical released. The results show that for the orifice plate of the hydrodynamic cavitation system, the possible location of the inception of the cavity spreads to throat and divergent section of the venturi geometry. Based on the surrogate model and global sensitivity assessment, the diameter of throat Dt and diameter of inlet Din significantly influenced the size of the cavity, while the length of throat Lt had little effect on both cavitation intensity and flow rate. It should be noted that when Lt is decreased, the size of cavity would be slightly decreased but the flow rate increased clearly. The increase of the diverging section is in favor of the size of cavity. By comparing the experimental measurements on the concentration of Methylene blue, the optimum geometry of the orifice plate for best cavitational activity is proposed

  12. Combined experimental and computational investigation of the cavitating flow in an orifice plate with special emphasis on surrogate-based optimization method

    Energy Technology Data Exchange (ETDEWEB)

    Li, XianLin; Huang, Biao; Chen, Tairan; Liu, Ying; Qiu, Si Cong [School of Mechanical and Vehicular Engineering, Beijing Institute of Technology, Beijing (China); Zhao, Jing [China Academy of Launch Vehicle Technology, Beijing (China)

    2017-01-15

    We investigated the influence of geometrical parameters of the orifice plate on the cavitation structures, and optimized these parameters by using a surrogate-based model with special emphasis on the concentration of hydroxyl radical released. The results show that for the orifice plate of the hydrodynamic cavitation system, the possible location of the inception of the cavity spreads to throat and divergent section of the venturi geometry. Based on the surrogate model and global sensitivity assessment, the diameter of throat Dt and diameter of inlet Din significantly influenced the size of the cavity, while the length of throat Lt had little effect on both cavitation intensity and flow rate. It should be noted that when Lt is decreased, the size of cavity would be slightly decreased but the flow rate increased clearly. The increase of the diverging section is in favor of the size of cavity. By comparing the experimental measurements on the concentration of Methylene blue, the optimum geometry of the orifice plate for best cavitational activity is proposed.

  13. Effect of the particle to fluid density ratio on bedform development: An application of PTV

    Science.gov (United States)

    McKenna Neuman, C. L.; Gordon, M. D.

    2009-05-01

    The particle to fluid density ratio plays a key role in sediment transport and strongly governs the relative importance of the transport mode. In aeolian systems, this ratio is three orders of magnitude larger than for the transport of sedimentary particles in water, such that saltation is the dominant mode for diameters (250 microns) commonly found in ripples and dunes. The partitioning of fluid momentum to saltators, and therefore to the surface upon impact, is extremely important to the entrainment of sediment, the maintenance of transport, and the scaling of aeolian bedforms. This paper demonstrates the use of Particle Tracking Velocimetry in measuring the partitioning of momentum associated with particle collisions on beds of quartz sand (2630 kg m-3) typical of aeolian dunes, and acrylic particles (1210 kg m-3) similar to blowing snow (920 kg m-3). The experiments were carried out in the boundary layer wind tunnel at Trent University on full beds that were 13.8 m in length and 0.71 m in width. In the majority of experiments, the wind speeds were either at or just above the threshold for saltation so that we could distinguish discrete particle trajectories. Surface ripples formed in the majority of experiments and passed through the camera's field of view so that the height, length and rate of migration could be measured in relation to the distributions of particle impact speed and angle, as well as those for the number, speed and angle of the particles ejected. Although similar in height, the ripples comprised of acrylic particles were 2 to 4 times longer, much more asymmetric, and migrated significantly faster than those in sand. The particle impact and ejection speeds were very similar, although the sand particles approached and left the bed at substantially larger angles than observed for the lighter acrylic particles of similar diameter. In a separate experiment, glass beads were flung onto each bed material at 4 ms-1 in still air. It was discovered that

  14. Finger length ratio (2D:4D) in adults with gender identity disorder.

    Science.gov (United States)

    Kraemer, Bernd; Noll, Thomas; Delsignore, Aba; Milos, Gabriella; Schnyder, Ulrich; Hepp, Urs

    2009-06-01

    From early childhood, gender identity and the 2nd to 4th finger length ratio (2D:4D) are discriminative characteristics between sexes. Both the human brain and 2D:4D may be influenced by prenatal testosterone levels. This calls for an examination of 2D:4D in patients with gender identity disorder (GID) to study the possible influence of prenatal testosterone on gender identity. Until now, the only study carried out on this issue suggests lower prenatal testosterone levels in right-handed male-to-female GID patients (MtF). We compared 2D:4D of 56 GID patients (39 MtF; 17 female-to-male GID patients, FtM) with data from a control sample of 176 men and 190 women. Bivariate group comparisons showed that right hand 2D:4D in MtF was significantly higher (feminized) than in male controls, but similar to female controls. The comparison of 2D:4D ratios of biological women revealed significantly higher (feminized) values for right hands of right handed FtM. Analysis of variance confirmed significant effects for sex and for gender identity on 2D:4D ratios but not for sexual orientation or for the interaction among variables. Our results indirectly point to the possibility of a weak influence of reduced prenatal testosterone as an etiological factor in the multifactorially influenced development of MtF GID. The development of FtM GID seems even more unlikely to be notably influenced by prenatal testosterone.

  15. Inertial migrations of cylindrical particles in rectangular microchannels: Variations of equilibrium positions and equivalent diameters

    Science.gov (United States)

    Su, Jinghong; Chen, Xiaodong; Hu, Guoqing

    2018-03-01

    Inertial migration has emerged as an efficient tool for manipulating both biological and engineered particles that commonly exist with non-spherical shapes in microfluidic devices. There have been numerous studies on the inertial migration of spherical particles, whereas the non-spherical particles are still largely unexplored. Here, we conduct three-dimensional direct numerical simulations to study the inertial migration of rigid cylindrical particles in rectangular microchannels with different width/height ratios under the channel Reynolds numbers (Re) varying from 50 to 400. Cylindrical particles with different length/diameter ratios and blockage ratios are also concerned. Distributions of surface force with the change of rotation angle show that surface stresses acting on the particle end near the wall are the major contributors to the particle rotation. We obtain lift forces experienced by cylindrical particles at different lateral positions on cross sections of two types of microchannels at various Re. It is found that there are always four stable equilibrium positions on the cross section of a square channel, while the stable positions are two or four in a rectangular channel, depending on Re. By comparing the equilibrium positions of cylindrical particles and spherical particles, we demonstrate that the equivalent diameter of cylindrical particles monotonously increases with Re. Our work indicates the influence of a non-spherical shape on the inertial migration and can be useful for the precise manipulation of non-spherical particles.

  16. Retinal vessel diameter and estimated cerebrospinal fluid pressure in arterial hypertension: the Beijing Eye Study.

    Science.gov (United States)

    Jonas, Jost B; Wang, Ningli; Wang, Shuang; Wang, Ya Xing; You, Qi Sheng; Yang, Diya; Wei, Wen Bin; Xu, Liang

    2014-09-01

    Hypertensive retinal microvascular abnormalities include an increased retinal vein-to-artery diameter ratio. Because central retinal vein pressure depends on cerebrospinal fluid pressure (CSFP), we examined whether the retinal vein-to-artery diameter ratio and other retinal hypertensive signs are associated with CSFP. Participants of the population-based Beijing Eye Study (n = 1,574 subjects) underwent measurement of the temporal inferior and superior retinal artery and vein diameter. CSFP was calculated as 0.44 × body mass index (kg/m(2)) + 0.16 × diastolic blood pressure (mm Hg) - 0.18 × age (years) - 1.91. Larger retinal vein diameters and higher vein-to-artery diameter ratios were significantly associated with higher estimated CSFP (P = 0.001) in multivariable analysis. In contrast, temporal inferior retinal arterial diameter was marginally associated (P = 0.03) with estimated CSFP, and temporal superior artery diameter was not significantly associated (P = 0.10) with estimated CSFP; other microvascular abnormalities, such as arteriovenous crossing signs, were also not significantly associated with estimated CSFP. In a reverse manner, higher estimated CSFP as a dependent variable in the multivariable analysis was associated with wider retinal veins and higher vein-to-artery diameter ratio. In the same model, estimated CSFP was not significantly correlated with retinal artery diameters or other retinal microvascular abnormalities. Correspondingly, arterial hypertension was associated with retinal microvascular abnormalities such as arteriovenous crossing signs (P = 0.003), thinner temporal retinal arteries (P arterial hypertension, an increased retinal vein-to-artery diameter ratio depends on elevated CSFP, which is correlated with blood pressure. © American Journal of Hypertension, Ltd 2014. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Diameter of the thoracic and abdominal aorta in healthy Japanese

    International Nuclear Information System (INIS)

    Matsunaga, Wakako

    1989-01-01

    In 300 cases, diameter of thoracic and abdominal aorta in healthy Japanese is measured by computed tomography (CT) and the values are analyzed in relation to the age, sex and the level of the aorta on CT scan. Aorta becomes dilated with age. In female diameter of the aorta is correlated with age, on the other hand, diameter of those is not correlated with age in male. Diameter in male is larger than in female. Aorta tapers off and the ratio of tapering of the thoracic aorta is more prominent than that of the abdominal aorta. Therefore the calculations of the landmarks of tapering of the aorta and the ratio of diameter of the aorta to transverse diameter of the vertebral body at the levels of 10th thoracic and 3rd lumber vertebrae on CT scan are useful for judgement of normal range of diameter of the aorta. Calcifications of the wall of the aorta are seen initially at the age of 5th decade in the abdominal aorta and 6th decade in the thoracic aorta in healthy Japanese. They are noted in almost of the persons after the age of seventy years old. The presence of calcification is not correlated with diameter of the aorta at the same level on CT scan. (author)

  18. Instability of Reference Diameter in the Evaluation of Stenosis After Coronary Angioplasty: Percent Diameter Stenosis Overestimates Dilative Effects Due to Reference Diameter Reduction

    International Nuclear Information System (INIS)

    Hirami, Ryouichi; Iwasaki, Kohichiro; Kusachi, Shozo; Murakami, Takashi; Hina, Kazuyoshi; Matano, Shigeru; Murakami, Masaaki; Kita, Toshimasa; Sakakibara, Noburu; Tsuji, Takao

    2000-01-01

    Purpose: To examine changes in the reference segment luminal diameter after coronary angioplasty.Methods: Sixty-one patients with stable angina pectoris or old myocardial infarction were examined. Coronary angiograms were recorded before coronary angioplasty (pre-angioplasty) and immediately after (post-angioplasty), as well as 3 months after. Artery diameters were measured on cine-film using quantitative coronary angiographic analysis.Results: The diameters of the proximal segment not involved in the balloon inflation and segments in the other artery did not change significantly after angioplasty, but the reference segment diameter significantly decreased (4.7%). More than 10% luminal reduction was observed in seven patients (11%) and more than 5% reduction was observed in 25 patients (41%). More than 5% underestimation of the stenosis was observed in 22 patients (36%) when the post-angioplasty reference diameter was used as the reference diameter, compared with when the pre-angioplasty measurement was used and more than 10% underestimation was observed in five patients (8%).Conclusion: This study indicated that evaluation by percent diameter stenosis, with the reference diameter from immediately after angioplasty, overestimates the dilative effects of coronary angioplasty, and that it is thus better to evaluate the efficacy of angioplasty using the absolute diameter in addition to percent luminal stenosis

  19. Early-to-mid gestation fetal testosterone increases right hand 2D:4D finger length ratio in polycystic ovary syndrome-like monkeys.

    Directory of Open Access Journals (Sweden)

    Andrew D Abbott

    Full Text Available A smaller length ratio for the second relative to the fourth finger (2D:4D is repeatedly associated with fetal male-typical testosterone (T and is implicated as a biomarker for a variety of traits and susceptibility to a number of diseases, but no experimental human studies have been performed. The present study utilizes the rhesus monkey, a close relative of humans, and employs discrete gestational exposure of female monkeys to fetal male-typical T levels for 15-35 days during early-to-mid (40-76 days; n = 7 or late (94-139 days; n = 7 gestation (term: 165 days by daily subcutaneous injection of their dams with 10 mg T propionate. Such gestational exposures are known to enhance male-typical behavior. In this study, compared to control females (n = 19, only early-to-mid gestation T exposure virilizes female external genitalia while increasing 2D:4D ratio in the right hand (RH by male-like elongation of RH2D. RH2D length and 2D:4D positively correlate with androgen-dependent anogenital distance (AG, and RH2D and AG positively correlate with duration of early-to-mid gestation T exposure. Male monkeys (n = 9 exhibit a sexually dimorphic 2D:4D in the right foot, but this trait is not emulated by early-to-mid or late gestation T exposed females. X-ray determined phalanx measurements indicate elongated finger and toe phalanx length in males, but no other phalanx-related differences. Discrete T exposure during early-to-mid gestation in female rhesus monkeys thus appears to increase RH2D:4D through right-side biased, non-skeletal tissue growth. As variation in timing and duration of gestational T exposure alter male-like dimensions of RH2D independently of RH4D, postnatal RH2D:4D provides a complex biomarker for fetal T exposure.

  20. A Visual Basic program to classify sediments based on gravel-sand-silt-clay ratios

    Science.gov (United States)

    Poppe, L.J.; Eliason, A.H.; Hastings, M.E.

    2003-01-01

    Nomenclature describing size distributions is important to geologists because grain size is the most basic attribute of sediments. Traditionally, geologists have divided sediments into four size fractions that include gravel, sand, silt, and clay, and classified these sediments based on ratios of the various proportions of the fractions. Definitions of these fractions have long been standardized to the grade scale described by Wentworth (1922), and two main classification schemes have been adopted to describe the approximate relationship between the size fractions.Specifically, according to the Wentworth grade scale gravel-sized particles have a nominal diameter of ⩾2.0 mm; sand-sized particles have nominal diameters from <2.0 mm to ⩾62.5 μm; silt-sized particles have nominal diameters from <62.5 to ⩾4.0 μm; and clay is <4.0 μm. As for sediment classification, most sedimentologists use one of the systems described either by Shepard (1954) or Folk (1954, 1974). The original scheme devised by Shepard (1954) utilized a single ternary diagram with sand, silt, and clay in the corners to graphically show the relative proportions among these three grades within a sample. This scheme, however, does not allow for sediments with significant amounts of gravel. Therefore, Shepard's classification scheme (Fig. 1) was subsequently modified by the addition of a second ternary diagram to account for the gravel fraction (Schlee, 1973). The system devised by Folk (1954, 1974) is also based on two triangular diagrams (Fig. 2), but it has 23 major categories, and uses the term mud (defined as silt plus clay). The patterns within the triangles of both systems differ, as does the emphasis placed on gravel. For example, in the system described by Shepard, gravelly sediments have more than 10% gravel; in Folk's system, slightly gravelly sediments have as little as 0.01% gravel. Folk's classification scheme stresses gravel because its concentration is a function of

  1. Diagnostic value of newborn foot length to predict gestational age

    Directory of Open Access Journals (Sweden)

    Mutia Farah Fawziah

    2017-08-01

    Full Text Available Background  Identification of gestational age, especially within 48 hours of birth, is crucial for newborns, as the earlier preterm status is detected, the earlier the child can receive optimal management. Newborn foot length is an anthropometric measurement which is easy to perform, inexpensive, and potentially efficient for predicting gestational age. Objective  To analyze the diagnostic value of newborn foot length in predicting gestational age. Methods  This diagnostic study was performed between October 2016 and February 2017 in the High Care Unit of Neonates at Dr. Moewardi General Hospital, Surakarta. A total of 152 newborns were consecutively selected and underwent right foot length measurements before 96 hours of age. The correlation between newborn foot length to classify as full term and gestational age was analyzed with Spearman’s correlation test because of non-normal data distribution. The cut-off point of newborn foot length was calculated by receiver operating characteristic (ROC curve and diagnostic values of newborn foot length were analyzed by 2 x 2 table with SPSS 21.0 software. Results There were no significant differences between male and female newborns in terms of gestational age, birth weight, choronological age, and newborn foot length (P>0.05. Newborn foot length and gestational age had a significant correlation (r=0.53; P=0.000. The optimal cut-off newborn foot length to predict full term status was 7.1 cm. Newborn foot length below 7.1 cm had sensitivity 75%, specificity 98%, positive predictive value 94.3%, negative predictive value 90.6%, positive likelihood ratio 40.5, negative likelihood ratio 0.25, and post-test probability 94.29%, to predict preterm status in newborns. Conclusion  Newborn foot length can be used to predict gestational age, especially for the purpose of differentiating between preterm and full term newborns.

  2. Validation of the ureteral diameter ratio for predicting early spontaneous resolution of primary vesicoureteral reflux.

    Science.gov (United States)

    Arlen, Angela M; Kirsch, Andrew J; Leong, Traci; Cooper, Christopher S

    2017-08-01

    Management of primary vesicoureteral reflux (VUR) remains controversial, and reflux grade currently constitutes an important prognostic factor. Previous reports have demonstrated that distal ureteral diameter ratio (UDR) may be more predictive of outcome than vesicoureteral reflux (VUR) grade. We performed an external validation study in young children, evaluating early spontaneous resolution rates relative to reflux grade and UDR. Voiding cystourethrograms (VCUGs) were reviewed. UDR was computed by measuring largest ureteral diameter within the pelvis and dividing by the distance between the L1 and L3 vertebral bodies (Figure). VUR grade and UDR were tested in univariate and multivariable analyses. Primary outcome was status of VUR at last clinical follow-up (i.e. resolution, persistence, or surgical intervention). Demographics, VUR timing, laterality, and imaging indication were also assessed. One-hundred and forty-seven children (98 girls, 49 boys) were diagnosed with primary VUR at a mean age of 5.5 ± 4.7 months. Sixty-seven (45.6%) resolved spontaneously, 55 (37.4%) had persistent disease, and 25 (17%) were surgically corrected. Patients who spontaneously resolved had significantly lower VUR grade, refluxed later during bladder filling, and had significantly lower UDR. In a multivariable model, grade of VUR (p = 0.001), age early spontaneous resolution than grade alone. Furthermore, unlike traditional VUR grading where children with grade 1-5 may outgrow reflux depending on other factors, there appears to be a consistent UDR cutoff whereby patients are unlikely to resolve. In the present study, no child with a UDR greater than 0.43 experienced early spontaneous resolution, and only three (4.5%) of those with spontaneous resolution had a UDR above 0.35. UDR correlates with reflux grade, and is predictive of early resolution in children with primary VUR. UDR is an objective measurement of VUR, and provides valuable prognostic information about spontaneous

  3. Effect of particle diameter of porous media on flow and heat transfer in a mixing tee

    International Nuclear Information System (INIS)

    Wang, Yongwei; Lu, Tao; Wang, Kuisheng

    2012-01-01

    Highlights: ► Three particle diameter cases of 28 mm, 14 mm and 7 mm were simulated by LES. ► With the diameter decreasing, mixing scale tends to decrease in the mixing tee. ► With the diameter decreasing, thermal mixing is weakened. ► With the diameter decreasing, the thermal stratification is obvious. ► When the particle diameter ratio is 4:2:1, pressure drop ratio is 1:2:4. -- Abstract: Numerical simulations have been carried out to investigate flow and heat transfer in a mixing tee filled with periodic sintered copper spheres. Three particle diameter cases of 28 mm, 14 mm and 7 mm with the array of 4 × 4, 8 × 8 and 16 × 16 at the same porosity of 0.3 have been calculated using large-eddy simulations and the Smagorinsky–Lilly sub-grid scale model. With the particle diameter decreasing, the mixture scale of hot and cold fluid tends to decrease in the mixing tee; the pressure drop of fluid flow through porous media increases. When the particle diameter ratios are 4:2:1 and the specific surface ratios are 1:2:4, the pressure drop ratios are 1:2:4; the thermal mixing in porous media is weakened because the temperature fluctuation decreases and the stratification of hot and cold fluids is observed.

  4. Exploring the newborn head diameters in relation to current obstetric forceps' dimensions: A systematic review.

    Science.gov (United States)

    T Ismail, Abdul-Qader; Yates, Derick; Chester, Jonathan; Ismail, Khaled M K

    2018-01-01

    The aim of this study was to systematically search the literature for studies that reported term neonate head size and shape, in an attempt to determine the most appropriate dimensions for the obstetric forceps. We searched the Ovid Medline, Ovid Embase and Ebscohost CINAHL databases from inception to February 2016. We predefined inclusion criteria to identify studies in which head width and length of asymptomatic, term neonates were measured soon after birth using direct, non-photographic methods A bespoke quality assessment score was used to evaluate the identified studies. Seven studies were identified which measured head width (biparietal diameter) in 551 neonates; giving a mean value of 94.0mm (range 90.7mm-95.5mm). We identified one study which measured head length (mentovertical diameter) in 38 neonates; which gave a mean value of 134.5mm (range 129mm-139mm). This data, in conjunction with measurements of Neville Barnes' and Wrigley's forceps from our previous study, indicates current obstetric forceps' blades are too long, and close together. Potentially, this could be contributing to neonatal and maternal injuries associated with operational vaginal deliveries. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Responses of Several Apple Cultivars to Chemical Thinning Sprays ...

    African Journals Online (AJOL)

    Nevertheless, significantly (P 0.05) the number of seeds in the fruit, fruit the treatments did not affect (P length, fruit diameter and fruit length to diameter ratio. The chemical thinner and cultivar interactions were significant for some fruit characteristics. The Journal of Food Technology in Africa Volume 7 No.1, 2002, pp.

  6. Odd Length Contraction

    Science.gov (United States)

    Smarandache, Florentin

    2013-09-01

    Let's denote by VE the speed of the Earth and byVR the speed of the rocket. Both travel in the same direction on parallel trajectories. We consider the Earth as a moving (at a constant speed VE -VR) spacecraft of almost spherical form, whose radius is r and thus the diameter 2r, and the rocket as standing still. The non-proper length of Earth's diameter, as measured by the astronaut is: L = 2 r√{ 1 -|/VE -VR|2 c2 } rocket! Also, let's assume that the astronaut is laying down in the direction of motion. Therefore, he would also shrink, or he would die!

  7. Tree diameter at breast height in relation to stump diameter by species group

    Science.gov (United States)

    Arthur G. Horn; Richard C. Keller

    1957-01-01

    A stump tally is one method of determining the volume of timber previously removed from an area in a logging operation. To estimate volume of standing timber from stumps, foresters must first know the relationship between stump diameters and tree diameters at breast height (d.b.h.).

  8. Pull out Strength of Dual Outer Diameter Pedicle Screws Compared to Uncemented and Cemented Standard Pedicle Screws: A Biomechanical in vitro Study.

    Science.gov (United States)

    Lorenz, Andrea; Leichtle, Carmen I; Frantz, Sandra; Bumann, Marte; Tsiflikas, Ilias; Shiozawa, Thomas; Leichtle, Ulf G

    2017-05-01

    To analyze the potential of the dual outer diameter screw and systematically evaluate the pull-out force of the dual outer diameter screw compared to the uncemented and cemented standard pedicle screws with special regard to the pedicle diameter and the vertebra level. Sixty vertebrae of five human spines (T 6 -L 5 ) were sorted into three study groups for pairwise comparison of the uncemented dual outer diameter screw, the uncemented standard screw, and the cemented standard screw, and randomized with respect to bone mineral density (BMD) and vertebra level. The vertebrae were instrumented, insertion torque was determined, and pull-out testing was performed using a material testing machine. Failure load was evaluated in pairwise comparison within each study group. The screw-to-pedicle diameter ratio was determined and the uncemented dual outer diameter and standard screws were compared for different ratios as well as vertebra levels. Significantly increased pull-out forces were measured for the cemented standard screw compared to the uncemented standard screw (+689 N, P dual outer diameter screw (+403 N, P dual outer diameter screw to the uncemented standard screw in the total study group, a distinct but not significant increase was measured (+149 N, P = 0.114). Further analysis of these two screws, however, revealed a significant increase of pull-out force for the dual outer diameter screw in the lumbar region (+247 N, P = 0.040), as well as for a screw-to-pedicle diameter ratio between 0.6 and 1 (+ 488 N, P = 0.028). For clinical application, cement augmentation remains the gold standard for increasing screw stability. According to our results, the use of a dual outer diameter screw is an interesting option to increase screw stability in the lumbar region without cement augmentation. For the thoracic region, however, the screw-to-pedicle diameter should be checked and attention should be paid to screw cut out, if the dual outer diameter screw is considered.

  9. Keeping disease at arm's length

    DEFF Research Database (Denmark)

    Lassen, Aske Juul

    2015-01-01

    active ageing change everyday life with chronic disease, and how do older people combine an active life with a range of chronic diseases? The participants in the study use activities to keep their diseases at arm’s length, and this distancing of disease at the same time enables them to engage in social...... and physical activities at the activity centre. In this way, keeping disease at arm’s length is analysed as an ambiguous health strategy. The article shows the importance of looking into how active ageing is practised, as active ageing seems to work well in the everyday life of the older people by not giving...... emphasis to disease. The article is based on ethnographic fieldwork and uses vignettes of four participants to show how they each keep diseases at arm’s length....

  10. 33-Foot-Diameter Space Station Leading to Space Base

    Science.gov (United States)

    1969-01-01

    This picture illustrates a concept of a 33-Foot-Diameter Space Station Leading to a Space Base. In-house work of the Marshall Space Flight Center, as well as a Phase B contract with the McDornel Douglas Astronautics Company, resulted in a preliminary design for a space station in 1969 and l970. The Marshall-McDonnel Douglas approach envisioned the use of two common modules as the core configuration of a 12-man space station. Each common module was 33 feet in diameter and 40 feet in length and provided the building blocks, not only for the space station, but also for a 50-man space base. Coupled together, the two modules would form a four-deck facility: two decks for laboratories and two decks for operations and living quarters. Zero-gravity would be the normal mode of operation, although the station would have an artificial gravity capability. This general-purpose orbital facility was to provide wide-ranging research capabilities. The design of the facility was driven by the need to accommodate a broad spectrum of activities in support of astronomy, astrophysics, aerospace medicine, biology, materials processing, space physics, and space manufacturing. To serve the needs of Earth observations, the station was to be placed in a 242-nautical-mile orbit at a 55-degree inclination. An Intermediate-21 vehicle (comprised of Saturn S-IC and S-II stages) would have launched the station in 1977.

  11. Optical diameters of stars measured with the Mt. Wilson Mark III interferometer

    International Nuclear Information System (INIS)

    Simon, R.S.; Mozurkewich, D.; Johnston, K.J.; Gaume, R.; Hutter, D.J.; Bowers, P.F.; Colavita, M.M.; Shao, M.

    1990-01-01

    Reliable stellar angular diameters can now be determined using the Mark III Optical Interferometer located on Mt. Wilson, California. The Mark III is a Michelson Interferometer capable of measuring the interferometric fringe visibility for stars using interferometer baselines varying from 3 to 31.5 meters in length. Angular diameters measured with the Mark III Optical Interferometer are presented for 12 stars at wavelengths of 450 and 800 nm. 10 refs

  12. Reference interval for the disc-macula distance to disc diameter ratio in a large population of healthy Japanese adults: A prospective, observational study.

    Science.gov (United States)

    Sato, Ken-Ichi

    2017-04-01

    This study presents the calculated reference interval for the disc-to-macula distance to disc diameter ratio (DM:DD) based on a large population of healthy Japanese adults.A total of 308 consecutive, healthy Japanese adults were examined in this prospective observational study. Eighteen subjects were also excluded because of poor quality of the fundus photograph of one or both eyes; 290 (161 men and 129 women) were included in this study. For each subject, a color fundus photograph of one eye, either the right or left, was randomly selected and used for analysis. On the photograph, the distances between the fovea and the nearest temporal margin of the optic disc (Dft), and the two kinds of disc diameters (D1 and D2), which bisected at right angles and one of which was directed to the fovea (D1), were measured. DM:DD was estimated using the formula: (2Dft + D1)/(D1 + D2).The mean ± standard deviation of DM:DD was 2.91 ± 0.49 for men and 2.96 ± 0.54 for women; there was no sex difference (P = .78, Mann-Whitney U test). Also, almost no relationship was found between DM:DD and age (ρ = -.12, P = .04, Spearman's rank correlation coefficient). The data did not fit a normal distribution (P < .001, Kolmogorov-Smirnov test). The estimated reference interval for DM:DD corresponding to the 2.5th and 97.5th percentiles was 2.12 to 4.18.Using a nonparametric approach, the reference interval for DM:DD of a large population of healthy Japanese adults was calculated to be 2.12 to 4.18, regardless of age or sex.

  13. Hydrodynamics of long-scale-length plasmas. Summary

    International Nuclear Information System (INIS)

    Craxton, R.S.

    1984-01-01

    A summary is given relating to the importance of long-scale-length plasmas to laser fusion. Some experiments are listed in which long-scale-length plasmas have been produced and studied. This talk presents SAGE simulations of most of these experiments with the emphasis being placed on understanding the hydrodynamic conditions rather than the parametric/plasma-physics processes themselves which are not modeled by SAGE. However, interpretation of the experiments can often depend on a good understanding of the hydrodynamics, including optical ray tracing

  14. An experimental study of damping characteristics with emphasis on insulation for nuclear power plant piping system (Seismic Damping Ratio Evaluation Program)

    International Nuclear Information System (INIS)

    Shibata, H.; Ito, M.; Hayashi, T.; Chiba, T.; Kobayashi, H.; Kitamura, K.; Ando, K.; Koyanagi, R.

    1981-01-01

    To clarify the damping characteristics and mechanism in nuclear power plant piping systems, the study group was established and conducted to study SDREP (Seismic Damping Ratio Evaluation Program). As the Phase II of this study, vibration tests were conducted to investigate factors which might contribute to damping characteristics of piping systems. These tests are composed of the next three model tests: 1) The component damping characteristics test of thermal insulator 2) The simplified piping model test 3) The scale model test. In these tests, we studied damping characteristics with emphasis on thermal insulator (mainly calcium silicate insulator). The acceleartion level of pipings is the same as that of the actual seismic response. The excitation was by sinusoidal sweep method using the shaking table and by free vibration method using snapback. (orig./RW)

  15. PAPR Reduction in All-optical OFDM Systems Based on Phase Pre-emphasis

    Energy Technology Data Exchange (ETDEWEB)

    He Zhou; Li, Wei; Shao Jing; Liang Xiaojun; Huang Dexiu [Wuhan National Lab for Optoelectronics, Department of Optoelectronics Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China); Tao Zhiyong [State Key Laboratory of Optical Communication Technologies and Networks, Wuhan Research Institute of Posts and Telecommunications, Wuhan 430074 (China); Deng Zhuanhua, E-mail: hezhou@wri.com.cn, E-mail: weilee@mail.hust.edu.cn [School of Computer Science and Technology, Hubei University of Economics, Wuhan 430205 (China)

    2011-02-01

    This paper investigates the peak-to-average power ratio (PAPR) theory in all-optical orthogonal frequency division multiplexing (OFDM) optical fibre communication systems. We find out that phase pre-emphasis could effectively reduce PAPR in all-optical OFDM communication systems which employ intensity modulation-direct detection (IM-DD) method. An equation is developed and proposed to calculate suitable phasing values for pre-emphasis. Furthermore, we find out that phase pre-emphasis cannot reduce PAPR effectively in all-optical OFDM systems that employ Phase Shift Keying (PSK) or Quadracture Amplitude Modulation (QAM) method.

  16. PAPR Reduction in All-optical OFDM Systems Based on Phase Pre-emphasis

    International Nuclear Information System (INIS)

    He Zhou; Li, Wei; Shao Jing; Liang Xiaojun; Huang Dexiu; Tao Zhiyong; Deng Zhuanhua

    2011-01-01

    This paper investigates the peak-to-average power ratio (PAPR) theory in all-optical orthogonal frequency division multiplexing (OFDM) optical fibre communication systems. We find out that phase pre-emphasis could effectively reduce PAPR in all-optical OFDM communication systems which employ intensity modulation-direct detection (IM-DD) method. An equation is developed and proposed to calculate suitable phasing values for pre-emphasis. Furthermore, we find out that phase pre-emphasis cannot reduce PAPR effectively in all-optical OFDM systems that employ Phase Shift Keying (PSK) or Quadracture Amplitude Modulation (QAM) method.

  17. Fabrication of diameter-modulated and ultrathin porous nanowires in anodic aluminum oxide templates

    Energy Technology Data Exchange (ETDEWEB)

    Sulka, Grzegorz D., E-mail: Sulka@chemia.uj.edu.pl [Max Planck Institute of Microstructure Physics, Weinberg 2, 06120 Halle (Germany); Department of Physical Chemistry and Electrochemistry, Jagiellonian University, Ingardena 3, 30060 Krakow (Poland); Brzozka, Agnieszka [AGH University of Science and Technology, Faculty of Non-Ferrous Metals, Al. Mickiewicza 30, Krakow 30-059 (Poland); Liu, Lifeng [Max Planck Institute of Microstructure Physics, Weinberg 2, 06120 Halle (Germany)

    2011-05-30

    Graphical abstract: Display Omitted Highlights: > AAO templates with modulated pore diameter were fabricated by pulse anodization. > HA pulse duration tunes the shape of pores and the structure of AAO channels. > Au, Ag, Ni and Ag-Au diameter-modulated nanowires were synthetized. > Porous ultrathin Au nanowires were obtained by dealloying Ag-Au nanowires. - Abstract: Anodic aluminum oxide (AAO) membranes with modulated pore diameter were synthesized by pulse anodization in 0.3 M sulfuric acid at 1 deg. C. For AAO growth, a typical combination of alternating mild anodizing (MA) and hard anodizing (HA) pulses with applied potential pulses of 25 V and 35 V was applied. The control of the duration of HA pulses will provide an interesting way to tune the shape of pores and the structure of AAO channels. It was found that a non-uniform length of HA segments in cross section of AAO is usually observed when the HA pulse duration is shorter than 1.2 s. The pulse anodization performed with longer HA pulses leads to the formation of AAO templates with periodically modulated pore diameter and nearly uniform length of segments. Various diameter-modulated metallic nanowires (Au, Ag, Ni and Ag-Au) were fabricated by electrodeposition in the pores of anodic alumina membranes. A typical average nanowire diameter was about 30 nm and 48 nm for MA and HA nanowire segments, respectively. After a successful dealloying silver from Ag-Au nanowires, porous ultrathin Au nanowires were obtained.

  18. Fabrication of diameter-modulated and ultrathin porous nanowires in anodic aluminum oxide templates

    International Nuclear Information System (INIS)

    Sulka, Grzegorz D.; Brzozka, Agnieszka; Liu, Lifeng

    2011-01-01

    Graphical abstract: Display Omitted Highlights: → AAO templates with modulated pore diameter were fabricated by pulse anodization. → HA pulse duration tunes the shape of pores and the structure of AAO channels. → Au, Ag, Ni and Ag-Au diameter-modulated nanowires were synthetized. → Porous ultrathin Au nanowires were obtained by dealloying Ag-Au nanowires. - Abstract: Anodic aluminum oxide (AAO) membranes with modulated pore diameter were synthesized by pulse anodization in 0.3 M sulfuric acid at 1 deg. C. For AAO growth, a typical combination of alternating mild anodizing (MA) and hard anodizing (HA) pulses with applied potential pulses of 25 V and 35 V was applied. The control of the duration of HA pulses will provide an interesting way to tune the shape of pores and the structure of AAO channels. It was found that a non-uniform length of HA segments in cross section of AAO is usually observed when the HA pulse duration is shorter than 1.2 s. The pulse anodization performed with longer HA pulses leads to the formation of AAO templates with periodically modulated pore diameter and nearly uniform length of segments. Various diameter-modulated metallic nanowires (Au, Ag, Ni and Ag-Au) were fabricated by electrodeposition in the pores of anodic alumina membranes. A typical average nanowire diameter was about 30 nm and 48 nm for MA and HA nanowire segments, respectively. After a successful dealloying silver from Ag-Au nanowires, porous ultrathin Au nanowires were obtained.

  19. Mathematical model to predict temperature profile and air–fuel equivalence ratio of a downdraft gasification process

    International Nuclear Information System (INIS)

    Jaojaruek, Kitipong

    2014-01-01

    Highlights: • A mathematical model based on finite computation analysis was developed. • Model covers all zones of gasification process which will be useful to improve gasifier design. • Model can predict temperature profile, feedstock consumption rate and reaction equivalent ratio (ϕ). • Model-predicted parameters fitted well with experimental values. - Abstract: A mathematical model for the entire length of a downdraft gasifier was developed using thermochemical principles to derive energy and mass conversion equations. Analysis of heat transfer (conduction, convection and radiation) and chemical kinetic technique were applied to predict the temperature profile, feedstock consumption rate (FCR) and reaction equivalence ratio (RER). The model will be useful for designing gasifiers, estimating output gas composition and gas production rate (GPR). Implicit finite difference method solved the equations on the considered reactor length (50 cm) and diameter (20 cm). Conversion criteria for calculation of temperature and feedstock consumption rate were 1 × 10 −6 °C and 1 × 10 −6 kg/h, respectively. Experimental validation showed that model outputs fitted well with experimental data. Maximum deviation between model and experimental data of temperature, FCR and RER were 52 °C at combustion temperature 663 °C, 0.7 kg/h at the rate 8.1 kg/h and 0.03 at the RER 0.42, respectively. Experimental uncertainty of temperature, FCR and RER were 24.4 °C, 0.71 kg/h and 0.04, respectively, on confidence level of 95%

  20. Maternal smoking during pregnancy and possible effects of in utero testosterone: evidence from the 2D:4D finger length ratio

    NARCIS (Netherlands)

    Rizwan, S.; Manning, J. T.; Brabin, B. J.

    2007-01-01

    OBJECTIVES: Maternal smoking during pregnancy is linked to high fetal testosterone (FT), and an increased risk in offspring for autism, ADHD, conduct disorder, antisocial behaviour and criminal outcomes. The ratio of the length of the 2nd and 4th fingers (2D:4D) is thought to be negatively related

  1. Maximum tumor diameter is not an independent prognostic factor in high-risk localized prostate cancer

    NARCIS (Netherlands)

    Oort, van I.M.; Witjes, J.A.; Kok, D.E.G.; Kiemeney, L.A.; Hulsbergen-van de Kaa, C.A.

    2008-01-01

    Previous studies suggest that maximum tumor diameter (MTD) is a predictor of recurrence in prostate cancer (PC). This study investigates the prognostic value of MTD for biochemical recurrence (BCR) in patients with PC, after radical prostatectomy (RP), with emphasis on high-risk localized prostate

  2. The method to design the length of thin-wall flexible rotor

    International Nuclear Information System (INIS)

    Zhang Yue; Yao Zengzhong; Baigu Lafu

    2014-01-01

    Thin-wall flexible rotor is frequently used in rotating machinery. For this rotor the vibration is very complex under the working speed. So the composition design is very difficult. In this paper, for a thin-wall flexible rotor, the material and rotor diameter are determined from spatial structure, the working speed is determined from strength of the material, the first bending critical speed is determined from working speed, then the influence of length on the critical speed is researched. According to the influence of critical speed on the vibration, the length design method is researched, the design steps and methods are given, the safety margin of vibration is analysed. Design validity is established by test. The method is generally suitable for thin-wall flexible rotor. (authors)

  3. Novel Laser-Based Technique for Measurements of Primary Atomization Characteristics of Liquid Jets

    Science.gov (United States)

    2012-08-22

    worth noting that round supercavitating nozzles were used that had sharp edged inlets and exits, with length-to-diameter ratios smaller than 3. This...noting that round supercavitating nozzles were used that had sharp edged inlets and exits, with length-to-diameter ratios smaller than 3. This...breakup. It is worth noting that round supercavitating nozzles were used that had sharp edged inlets and exits, with length-to-diameter ratios

  4. Role of the outer-edge flame on flame extinction in nitrogen-diluted non-premixed counterflow flames with finite burner diameters

    KAUST Repository

    Chung, Yong Ho

    2013-03-01

    This study of nitrogen-diluted non-premixed counterflow flames with finite burner diameters investigates the important role of the outer-edge flame on flame extinction through experimental and numerical analyses. It explores flame stability diagrams mapping the flame extinction response of nitrogen-diluted non-premixed counterflow flames to varying global strain rates in terms of burner diameter, burner gap, and velocity ratio. A critical nitrogen mole fraction exists beyond which the flame cannot be sustained; the critical nitrogen mole fraction versus global strain rate curves have C-shapes for various burner diameters, burner gaps, and velocity ratios. At sufficiently high strain-rate flames, these curves collapse into one curve; therefore, the flames follow the one-dimensional flame response of a typical diffusion flame. Low strain-rate flames are significantly affected by radial conductive heat loss, and therefore flame length. Three flame extinction modes are identified: flame extinction through shrinkage of the outer-edge flame with or without oscillations at the outer-edge flame prior to the extinction, and flame extinction through a flame hole at the flame center. The extinction modes are significantly affected by the behavior of the outer-edge flame. Detailed explanations are provided based on the measured flame-surface temperature and numerical evaluation of the fractional contribution of each term in the energy equation. Radial conductive heat loss at the flame edge to ambience is the main mechanism of extinction through shrinkage of the outer-edge flame in low strain-rate flames. Reduction of the burner diameter can extend the flame extinction mode by shrinking the outer-edge flame in higher strain-rate flames. © 2012 Elsevier Ltd. All rights reserved.

  5. Role of Fiber Length on Phagocytosis & Inflammatory Response

    Science.gov (United States)

    Turkevich, Leonid; Stark, Carahline; Champion, Julie

    2014-03-01

    Asbestos fibers have long been associated with lung cancer death. The inability of immune cells (e.g. macrophages) to effectively remove asbestos leads to chronic inflammation and disease. This study examines the role of fiber length on toxicity at the cellular level using model glass fibers. A major challenge is obtaining single diameter fibers but differing in length. Samples of 1 micron diameter fibers with different length distributions were prepared: short fibers (less than 15 microns) by aggressive crushing, and long fibers (longer than 15 microns) by successive sedimentation. Time-lapse video microscopy monitored the interaction of MH-S murine alveolar macrophages with the fibers: short fibers were easily internalized by the macrophages, but long fibers resisted internalization over many hours. Production of TNF- α (tumor necrosis factor alpha), a general inflammatory secreted cytokine, and Cox-2 (cyclo-oxygenase-2), an enzyme that produces radicals, each exhibited a dose-dependence that was greater for long than for short fibers. These results corroborate the importance of fiber length in both physical and biochemical cell response and support epidemiological observations of higher toxicity for longer fibers.

  6. Influence of the Diameter of Dental Implants Replacing Single Molars: 3- to 6-Year Follow-Up.

    Science.gov (United States)

    Mendonça, Jose Alfredo; Senna, Plinio Mendes; Francischone, Carlos Eduardo; Francischone Junior, Carlos Eduardo; Sotto-Maior, Bruno Salles

    The aim of this study was to evaluate the influence of the implant diameter on marginal bone remodeling around dental implants replacing single molars after a follow-up period of 3 to 6 years. Patients who received dental implants with an external hexagon platform in healed sites to support a single metal-ceramic crown in the molar region were recalled to the office. The implantation sites and implant length information were recorded, and the implants were divided according to the implant diameter: regular (RP) or wide (WP). Each implant was assessed by digital periapical radiography, using a sensor holder for the paralleling technique. The marginal bone remodeling was determined as the distance from the implant platform to the first bone-to-implant contact, and the known implant length was used to calibrate the images in the computer software. The follow-up measurements were compared with those obtained from the radiograph taken at the time of prosthetic loading to determine the late bone remodeling. The independent t test was used to compare data. A total of 67 implants from 46 patients were evaluated with a mean follow-up period of 4.5 ± 1.0 years. The RP group comprised 36 implants from 29 patients (mean age: 58.3 ± 10.6 years), while 31 implants from 17 patients (mean age: 56.9 ± 11.5 years) were included in the WP group. The RP group presented lower survival rates (86.1%) than the WP group (100.0%). Similar marginal bone loss (P implants exhibited lower incidence failures, the bone levels were similar after the prosthetic loading around regular- and wide-diameter implants supporting single molar crowns.

  7. Improved Design Basis for Laterally Loaded Large Diameter Pile

    DEFF Research Database (Denmark)

    Leth, Caspar Thrane

    of up-to-date facilities has been: Equipment for controlling centrifuge tests, data acquisition, preparation of test samples and equipment for and making of lateral load tests. The present research has been narrowed to investigate the static and cyclic behaviour of stiff piles with a diameter of 1-3 m...... in dry sand by use of centrifuge modelling and to compare the findings with the standard p-y curves. It has been chosen to apply piles with an embedment length of 6 to 10 times the diameter of the applied piles. The general static behaviour of monopiles in dry sand has based on centrifuge tests been...... with a capacity of 3.6 MW and placed at water depths beyond 25 m. Different foundation solutions have over the years been applied for offshore turbines, but monopiles are currently the most applied foundation type and are typically with a pile diameter of 4-6 m and applied up to a water depth of 25 m...

  8. Martian Low-Aspect-Ratio Layered Ejecta (LARLE) craters: Distribution, characteristics, and relationship to pedestal craters

    Science.gov (United States)

    Barlow, Nadine G.; Boyce, Joseph M.; Cornwall, Carin

    2014-09-01

    Low-Aspect-Ratio Layered Ejecta (LARLE) craters are a unique landform found on Mars. LARLE craters are characterized by a crater and normal layered ejecta pattern surrounded by an extensive but thin outer deposit which terminates in a sinuous, almost flame-like morphology. We have conducted a survey to identify all LARLE craters ⩾1-km-diameter within the ±75° latitude zone and to determine their morphologic and morphometric characteristics. The survey reveals 140 LARLE craters, with the majority (91%) located poleward of 40°S and 35°N and all occurring within thick mantles of fine-grained deposits which are likely ice-rich. LARLE craters range in diameter from the cut-off limit of 1 km up to 12.2 km, with 83% being smaller than 5 km. The radius of the outer LARLE deposit displays a linear trend with the crater radius and is greatest at higher polar latitudes. The LARLE deposit ranges in length between 2.56 and 14.81 crater radii in average extent, with maximum length extending up to 21.4 crater radii. The LARLE layer is very sinuous, with lobateness values ranging between 1.45 and 4.35. LARLE craters display a number of characteristics in common with pedestal craters and we propose that pedestal craters are eroded versions of LARLE craters. The distribution and characteristics of the LARLE craters lead us to propose that impact excavation into ice-rich fine-grained deposits produces a dusty base surge cloud (like those produced by explosion craters) that deposits dust and ice particles to create the LARLE layers. Salts emplaced by upward migration of water through the LARLE deposit produce a surficial duricrust layer which protects the deposit from immediate removal by eolian processes.

  9. Mechanical properties investigation on single-wall ZrO2 nanotubes: A finite element method with equivalent Poisson's ratio for chemical bonds

    Science.gov (United States)

    Yang, Xiao; Li, Huijian; Hu, Minzheng; Liu, Zeliang; Wärnå, John; Cao, Yuying; Ahuja, Rajeev; Luo, Wei

    2018-04-01

    A method to obtain the equivalent Poisson's ratio in chemical bonds as classical beams with finite element method was proposed from experimental data. The UFF (Universal Force Field) method was employed to calculate the elastic force constants of Zrsbnd O bonds. By applying the equivalent Poisson's ratio, the mechanical properties of single-wall ZrNTs (ZrO2 nanotubes) were investigated by finite element analysis. The nanotubes' Young's modulus (Y), Poisson's ratio (ν) of ZrNTs as function of diameters, length and chirality have been discussed, respectively. We found that the Young's modulus of single-wall ZrNTs is calculated to be between 350 and 420 GPa.

  10. Why is digit ratio correlated to sports performance?

    Science.gov (United States)

    Kim, Tae Beom; Kim, Khae Hawn

    2016-12-01

    Second to fourth digit ratio is the ratio of second to fourth digit length. It has been known that digit ratio is sexually dimorphic in humans, such that males tend to have lower digit ratio (longer fourth digits relative to second digits) than females. Digit ratio is thought to be a biomarker of the balance between fetal testosterone (FT) and fetal estrogen (FE) in a relatively narrow developmental window at the end of the first trimester of pregnancy. On the contrary, the relationships between digit ratio and levels of sex steroids in adults are not clear. Most correlational studies between digit ratio and adult sex steroids have revealed that this association is statistically not significant. However, for many years, a lot of researches showed negative relationships between digit ratio and sports performance such as rugby, surfing, rowing, sprinting, endurance, and hand grip strength. Here, we discuss possible mechanisms about the relationships between digit ratio and sports performance.

  11. A ball diameter-measuring instrument in a gauge block interferometer

    NARCIS (Netherlands)

    Kotte, G.J.W.L.; Haitjema, H.; Decker, J.E.; Brown, N.

    1998-01-01

    An instrument for the measurement of ball diameters in the 0.5-20 mm range in a gauge block interferometer is realized. The measurement principle is that the ball is positioned between an optical flat and a calibrated gauge block. The total length is measured in a gauge block relative to the optical

  12. Performance Analysis of a Modular Small-Diameter Air Distribution System

    Energy Technology Data Exchange (ETDEWEB)

    Poerschke, Andrew [IBACOS, Inc., Pittsburgh, PA (United States); Rudd, Armin [ABT Systems, LLC, Annville, PA (United States)

    2016-03-01

    This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space-conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to easily be brought within conditioned space via interior partition walls. Centrally locating the air handling unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives a similar amount of airflow—regardless of its position on the box. Furthermore, within a reasonable set of length restrictions each duct continues to receive similar airflow.

  13. A diameter increment model for Red Fir in California and Southern Oregon

    Science.gov (United States)

    K. Leroy Dolph

    1992-01-01

    Periodic (10-year) diameter increment of individual red fir trees in Califomia and southern Oregon can be predicted from initial diameter and crown ratio of each tree, site index, percent slope, and aspect of the site. The model actually predicts the natural logarithm ofthe change in squared diameter inside bark between the startand the end of a 10-year growth period....

  14. Axial Length/Corneal Radius of Curvature Ratio and Refractive ...

    African Journals Online (AJOL)

    2017-12-05

    Dec 5, 2017 ... variously described as determined by the ocular biometric variables. There have been many studies on the relationship between refractive error and ocular axial length (AL), anterior chamber depth, corneal radius of curvature (CR), keratometric readings as well as other ocular biometric variables such as ...

  15. Effects of Specimen Diameters on the Distribution of Corrosion Fatigue Cracks

    OpenAIRE

    石原, 外美; 塩澤, 和章; 宮尾, 嘉寿

    1988-01-01

    The distribution of corrosion fatigue cracks observed on the un-notched round specimen surface differs with specimen diameter, especially in the low stress amplitude region. At a constant fatigue life ratio, many long cracks are initiated on the larger specimen, 12 mm (diameter), in comparison with the smaller specimen, 6 mm (diameter). On the other hand, in the high stress amplitude region of corrosion fatigue and fatigue in laboratory air, the distribution of cracks during the fatigue proce...

  16. Correlation between MWCNT aspect ratio and the mechanical properties of composites of PMMA and MWCNTs

    Science.gov (United States)

    Mu, Mulan; Teblum, Eti; Figiel, Łukasz; Nessim, Gilbert Daniel; McNally, Tony

    2018-04-01

    The correlation between MWCNT aspect ratio and the quasi-static and dynamic mechanical properties of composites of MWCNTs and PMMA was studied for relatively long MWCNT lengths, in the range 0.3 mm to 5 mm (aspect ratios up to 5 × 105) and at low loading (0.15 wt%). The height of the MWCNTs prepared were modulated by controlling the amount of water vapour introduced in the reactor limiting Ostwald ripening of the catalyst, the formation of amorphous carbon and any increase in CNT diameter. The Tg of PMMA increased by up to 4 °C on addition of the longest tubes as they have the ability to form physical junctions with the polymer chains which lead to enhanced PMMA-MWCNTs interactions and increased mechanical properties, Young’s modulus by 20% on addition of 5 mm long MWCNTs. Predictions of the Young’s modulus of the composites of PMMA and MWCNT with the Mori-Tanaka theory show that future micromechanical models should account for MWCNT agglomeration and polymer-nanotube interactions as a function of CNT length.

  17. Evaluation of the normal thoracic and abdominal aorta diameters by computerized tomography

    International Nuclear Information System (INIS)

    Lucarelli, Claudio Luiz

    1995-01-01

    The study was undertaken to evaluate, through computerized tomography, the diameters of the normal thoracic and abdominal aorta, as well as they are connected to gender, age and body surface area; and the ratio between measurements obtained at the ascending and descending limbs of the thoracic aorta, and between the abdominal aortic diameters. For that reason, we measured the widest anteroposterior diameters of the thoracic aortas at the levels of the arch, the root, the pulmonary artery, and the thoracic-abdominal transition, as well as the level of the emergence of the superior mesenteric artery, of the renal hila and just cephalad to the bifurcation of the abdominal aortas of 350 patients without cardiovascular diseases who had undergone computerized tomography of the thorax and/or abdomen for any other reasons. Observation and statistic analyses led us to conclude that: 1) both the thoracic and abdominal aortic diameters are reduced from their proximal to their distal portions; 2) the body surface influences the size of the aorta, although only extreme variations alter the vessel's caliber; 3) vessel diameter was observed to gradually increase with age; 4) men were found to have larger diameters than age matched women; 5) the ratio between the ascending and descending aortic diameters varies according to gender and age; 6) the relations between abdominal aortic diameters measured at the level of renal hila and cephalad to the bifurcation are independent from gender and age. But the relation between those measured at the level of the superior mesenteric artery and cephalad to the bifurcation are linked to gender, but not to age. (author)

  18. Flow-driven simulation on variation diameter of counter rotating wind turbines rotor

    Directory of Open Access Journals (Sweden)

    Littik Y. Fredrika

    2018-01-01

    Full Text Available Wind turbines model in this paper developed from horizontal axis wind turbine propeller with single rotor (HAWT. This research aims to investigating the influence of front rotor diameter variation (D1 with rear rotor (D2 to the angular velocity optimal (ω and tip speed ratio (TSR on counter rotating wind turbines (CRWT. The method used transient 3D simulation with computational fluid dynamics (CFD to perform the aerodynamics characteristic of rotor wind turbines. The counter rotating wind turbines (CRWT is designed with front rotor diameter of 0.23 m and rear rotor diameter of 0.40 m. In this research, the wind velocity is 4.2 m/s and variation ratio between front rotor and rear rotor (D1/D2 are 0.65; 0.80; 1.20; 1.40; and 1.60 with axial distance (Z/D2 0.20 m. The result of this research indicated that the variation diameter on front rotor influence the aerodynamics performance of counter rotating wind turbines.

  19. Biological markers of asexuality: Handedness, birth order, and finger length ratios in self-identified asexual men and women.

    Science.gov (United States)

    Yule, Morag A; Brotto, Lori A; Gorzalka, Boris B

    2014-02-01

    Human asexuality is defined as a lack of sexual attraction to anyone or anything and it has been suggested that it may be best conceptualized as a sexual orientation. Non-right-handedness, fraternal birth order, and finger length ratio (2D:4D) are early neurodevelopmental markers associated with sexual orientation. We conducted an Internet study investigating the relationship between self-identification as asexual, handedness, number of older siblings, and self-measured finger-lengths in comparison to individuals of other sexual orientation groups. A total of 325 asexuals (60 men and 265 women; M age, 24.8 years), 690 heterosexuals (190 men and 500 women; M age, 23.5 years), and 268 non-heterosexuals (homosexual and bisexual; 64 men and 204 women; M age, 29.0 years) completed online questionnaires. Asexual men and women were 2.4 and 2.5 times, respectively, more likely to be non-right-handed than their heterosexual counterparts and there were significant differences between sexual orientation groups in number of older brothers and older sisters, and this depended on handedness. Asexual and non-heterosexual men were more likely to be later-born than heterosexual men, and asexual women were more likely to be earlier-born than non-heterosexual women. We found no significant differences between sexual orientation groups on measurements of 2D:4D ratio. This is one of the first studies to test and provide preliminary empirical support for an underlying neurodevelopmental basis to account for the lack of sexual attraction characteristic of asexuality.

  20. Diameter dependent electron transfer kinetics in semiconductor-enzyme complexes.

    Science.gov (United States)

    Brown, Katherine A; Song, Qing; Mulder, David W; King, Paul W

    2014-10-28

    Excited state electron transfer (ET) is a fundamental step for the catalytic conversion of solar energy into chemical energy. To understand the properties controlling ET between photoexcited nanoparticles and catalysts, the ET kinetics were measured for solution-phase complexes of CdTe quantum dots and Clostridium acetobutylicum [FeFe]-hydrogenase I (CaI) using time-resolved photoluminescence spectroscopy. Over a 2.0-3.5 nm diameter range of CdTe nanoparticles, the observed ET rate (kET) was sensitive to CaI concentration. To account for diameter effects on CaI binding, a Langmuir isotherm and two geometric binding models were created to estimate maximal CaI affinities and coverages at saturating concentrations. Normalizing the ET kinetics to CaI surface coverage for each CdTe diameter led to k(ET) values that were insensitive to diameter, despite a decrease in the free energy for photoexcited ET (ΔGET) with increasing diameter. The turnover frequency (TOF) of CaI in CdTe-CaI complexes was measured at several molar ratios. Normalization for diameter-dependent changes in CaI coverage showed an increase in TOF with diameter. These results suggest that k(ET) and H2 production for CdTe-CaI complexes are not strictly controlled by ΔG(ET) and that other factors must be considered.

  1. Numerical study of the effect of relative humidity and stoichiometric flow ratio on PEM (proton exchange membrane) fuel cell performance with various channel lengths: An anode partial flooding modelling

    International Nuclear Information System (INIS)

    Xing, Lei; Cai, Qiong; Xu, Chenxi; Liu, Chunbo; Scott, Keith; Yan, Yongsheng

    2016-01-01

    A two dimensional, along the channel, non-isothermal, two-phase flow, anode partial flooding model was developed to investigate the effects of relative humidity, stoichiometric flow ratio and channel length, as well as their interactive influence, on the performance of a PEM (proton exchange membrane) fuel cell. Liquid water formation and transport at the anode due to the condensation of supersaturated anode gas initiated by hydrogen consumption was considered. The model considered the heat source/sink in terms of electrochemical reaction, Joule heating and latent heat due to water phase-transfer. The non-uniform temperature distributions inside the MEA (membrane electrode assembly) and channels at various stoichiometric flow ratios were demonstrated. The Peclet number was used to evaluate the contributions of advection and diffusion on liquid water and heat transport. Results indicated that higher anode relative humidity is required to the improved cell performance. As the decrease in the anode relative humidity and increase in channel length, the optimal cathode relative humidity was increased. The initial increase in stoichiometric flow ratio improved the limiting current densities. However, the further increases led to limited contributions. The Peclet number indicated that the liquid water transport through the electrode was mainly determined by the capillary diffusion mechanism. - Highlights: • Interactive effects of RH, stoichiometric flow ratio, channel length are studied. • Fully humidified anode is required to maintain the good cell performance. • Optimal RH_c is 30–40% for channel length of 1–10 cm at high current density. • Effect of stoichiometric flow ratio is more significant for longer channels. • Both liquid water and heat transport are diffusion dominated rather than advection.

  2. Radiological examination in diagnosis of dolicho-sigmoid taking into consideration the colon and sigmoid length ratio in pediatric patients

    International Nuclear Information System (INIS)

    Bober, S.T.

    1993-01-01

    The aim of the study was usefulness evaluation of radiological examination in the diagnosis of dolicho sigmoid, especially establishing diagnosis criteria of pictures on contrast enema films which may be pathognomonic for dolicho sigmoid in children. An attempt has been made to establish objectively the length of sigmoid and colon to calculated the radio of their sizes in children with dolicho sigmoid syndrome and in control group. Contrast enemas were performed in 176 children. Among the examined children, in 26 cases dolicho sigmoid syndrome was found, including two cases of dolicho colon. Children with dolicho sigmoid syndrome showed various anomalies in elongated sigmoid location at its different levels. Generally, it was situated at the level of between L 1 and L 5 . The sigmoid formed often two or more abnormal loops with various bending and twisting or irregular protrusions. The coefficient or our invention concerned the ratio of colon length to the length of elongated sigmoid and on the basis of calculations made on children suffering from dolicho sigmoid syndrome the numerical values ranged from 0.7 to 1.5. The same calculations performed on the control for the proposed coefficient ranged from 2.2 to 4.2. (author). 65 refs, 15 figs, 11 tabs

  3. Accuracy of an improved device for remote measuring of tree-trunk diameters

    International Nuclear Information System (INIS)

    Matsushita, T.; Kato, S.; Komiyama, A.

    2000-01-01

    For measuring the diameters of tree trunks from a distant position, a recent device using a laser beam was developed by Kantou. We improved this device to serve our own practical purposes. The improved device consists of a 1-m-long metal caliper and a small telescope sliding smoothly onto it. Using the cross hairs in the scope, one can measure both edges of an object on the caliper and calculate its length. The laser beam is used just for guiding the telescopic sights to the correct positions on the object. In this study, the accuracy of this new device was examined by measuring objects of differing lengths, the distance from the object, and the angle of elevation to the object. Since each result of the experiment predicted absolute errors of measurement of less than 3 mm, this new device will be suitable for the measurement of trunk diameters in the field

  4. Analysis of in-R12 CHF data: influence of hydraulic diameter and heating length; test of Weisman boiling crisis model; Analyse de donnees de flux critique en R12: influence du diametre hydraulique et de la longueur chauffante; test du modele de Weisman

    Energy Technology Data Exchange (ETDEWEB)

    Czop, V; Herer, C; Souyri, A; Garnier, J

    1993-09-01

    In order to progress on the comprehensive modelling of the boiling crisis phenomenon, Electricite de France (EDF), Commissariat a l`Energie Atomique (CEA) and FRAMATOME have set up experimental programs involving in-R12 tests: the EDF APHRODITE program and the CEA-EDF-FRAMATOME DEBORA program. The first phase in these programs aims to acquire critical heat flux (CHF) data banks, within large thermal-hydraulic parameter ranges, both in cylindrical and annular configurations, and with different hydraulic diameters and heating lengths. Actually, three data banks have been considered in the analysis, all of them concerning in-R12 round tube tests: - the APHRODITE data bank, obtained at EDF with a 13 mn inside diameter, - the DEBORA data bank, obtained at CEA with a 19.2 mm inside diameter, - the KRISTA data bank, obtained at KfK with a 8 mm inside diameter. The analysis was conducted using CHF correlations and with the help of an advanced mathematical tool using pseudo-cubic thin plate type Spline functions. Two conclusions were drawn: -no influence of the heating length on our CHF results, - the influence of the diameter on the CHF cannot be simply expressed by an exponential function of this parameter, as thermal-hydraulic parameters also have an influence. Some calculations with Weisman and Pei theoretical boiling crisis model have been compared to experimental values: fairly good agreement was obtained, but further study must focus on improving the modelling of the influence of pressure and mass velocity. (authors). 12 figs., 4 tabs., 21 refs.

  5. Changes of Root Length and Root-to-Crown Ratio after Apical Surgery

    DEFF Research Database (Denmark)

    von Arx, Thomas; Jensen, Simon S; Bornstein, Michael M

    2015-01-01

    INTRODUCTION: Apical surgery is an important treatment option for teeth with post-treatment periodontitis. Although apical surgery involves root-end resection, no morphometric data are yet available about root-end resection and its impact on the root-to-crown ratio (RCR). The present study assess...

  6. homo sapiens are bilaterally symmetrical but not with toe length and ...

    African Journals Online (AJOL)

    Kevin Ongeti

    2017-11-12

    Nov 12, 2017 ... in toe length and toe-length ratios among the three major ethnic groups in Nigeria. A total ... The toe-length ratios also displayed symmetrical differences for ... For the female population, all ratios were not significantly different.

  7. Analysis of neutronic parameters related to reduction in fuel rod diameter for Angra-1 reactor fuel elements

    International Nuclear Information System (INIS)

    Faria, Eduardo F.; Sadde, Luciano M.; Sakai, Massao; Gomes, Sydney da S.

    2000-01-01

    The actual fuel element design for Angra-1 PWR satisfies in a very conservative way the design limits established for the critical heat flux as well as for the energy stored in the fuel rod. However, that is not an optimized design under neutronic considerations. The conservative ratio of the H and U atomic densities gives rise to a harder neutron spectrum which reduces its reactivity. In this report, a reduction in fuel rod diameters has been analyzed, keeping however the same rod pitch for geometrical compatibility reasons. By increasing the H/U ratio it is possible to obtain a net gain in reactivity. The optimized diameter in its turn should not jeopardize the reactor safety requirements. The actual trends of the nuclear industry is to extend the cycles and the enrichment by using advanced fuel design. It must be emphasized that this design change gives rise to economical advantages, for example, reduced costs for uranium utilization and enrichment with a net gain in reactivity. (author)

  8. Sonographic Measurement of Fetal Ear Length in Turkish Women with a Normal Pregnancy

    Directory of Open Access Journals (Sweden)

    Mucize Eriç Özdemir

    2014-12-01

    Full Text Available Background: Abnormal fetal ear length is a feature of chromosomal disorders. Fetal ear length measurement is a simple measurement that can be obtained during ultrasonographic examinations. Aims: To develop a nomogram for fetal ear length measurements in our population and investigate the correlation between fetal ear length, gestational age, and other standard fetal biometric measurements. Study Design: Cohort study. Methods: Ear lengths of the fetuses were measured in normal singleton pregnancies. The relationship between gestational age and fetal ear length in millimetres was analysed by simple linear regression. In addition, the correlation of fetal ear length measurements with biparietal diameter, head circumference, abdominal circumference, and femur length were evaluated.Ear length measurements were obtained from fetuses in 389 normal singleton pregnancies ranging between 16 and 28 weeks of gestation. Results: A nomogram was developed by linear regression analysis of the parameters ear length and gestational age. Fetal ear length (mm = y = (1.348 X gestational age-12.265, where gestational ages is in weeks. A high correlation was found between fetal ear length and gestational age, and a significant correlation was also found between fetal ear length and the biparietal diameter (r=0.962; p<0.001. Similar correlations were found between fetal ear length and head circumference, and fetal ear length and femur length. Conclusion: The results of this study provide a nomogram for fetal ear length. The study also demonstrates the relationship between ear length and other biometric measurements.

  9. Effect of rotor aspect ratio and solidity on a straight-bladed vertical axis wind turbine in three-dimensional analysis by the panel method

    International Nuclear Information System (INIS)

    Li, Qing'an; Maeda, Takao; Kamada, Yasunari; Shimizu, Kento; Ogasawara, Tatsuhiko; Nakai, Alisa; Kasuya, Takuji

    2017-01-01

    Due to the complated flow field and aerodynamic forces characteristics, the performance and safety standard of straight-bladed VAWT have not been full developed. The objective of this study is to investigate the effect of rotor aspect ratio and solidity on the power performance in three-dimensional analysis by panel method. The panel method is based on the assumption of an incompressible and potential flow coupled with a free vortex wake. First of all, the fluctuations of power coefficient and the circulation amount distribution of the bound vortex are discussed at the fixed solidity of σ = 0.064 during rotation. Then, the fluctuations of power coefficient and the circulation amount ratio are also investigated in the spanwise direction of the blade. It can be observed from the results that the peak of power coefficient increases with the increase of the ratio of the diameter and blade span length H/D at the fixed solidity. However, the optimum tip speed ratio was expected to be increased with the increase of H/D. Moreover, in the case of the fixed rotor aspect ratio of H/c = 6, the power coefficient depends on the rotor aspect ratio, rather than the ratio of the diameter and blade span length. Compared with the H/D = 1.2, the circulation amount ratio of H/D = 0.9 indicates a large negative value in the blade center position. - Highlights: • Power and vortex characteristic are discussed with panel method. • Effects of the rotor aspect ratio and solidity on the performance are investigated. • For the σ = 0.064, the maximum power coefficient increases with increasing of H/D. • Circulation amount ratio indicates a large negative value in the case of H/D = 0.9. • Power at the blade central position increases with increasing of rotor aspect ratio.

  10. Pharyngeal diameter in various head and neck positions during exercise in sport horses

    Science.gov (United States)

    2014-01-01

    Background In equine athletes, dynamic stenotic disorders of the upper airways are often the cause for abnormal respiratory noises and/or poor performance. There are hypotheses, that head and neck flexion may influence the morphology and function of the upper airway and thus could even induce or deteriorate disorders of the upper respiratory tract. Especially the pharynx, without osseous or cartilaginous support is prone to changes in pressure and airflow during exercise. The objective of this study was to develop a method for measuring the pharyngeal diameter in horses during exercise, in order to analyse whether a change of head-neck position may have an impact on the pharyngeal diameter. Results Under the assumption that the width of the epiglottis remains constant in healthy horses, the newly developed method for calculating the pharyngeal diameter in horses during exercise is unsusceptible against changes of the viewing-angle and distance between the endoscope and the structures, which are to be assessed. The quotient of the width of the epiglottis and the perpendicular from a fixed point on the dorsal pharynx to the epiglottis could be used to determine the pharyngeal diameter. The percentage change of this quotient (pharynx-epiglottis-ratio; PE-ratio) in the unrestrained head-neck position against the reference position was significantly larger than that of any other combination of the head-neck positions investigated. A relation between the percentage change in PE-ratio and the degree of head and neck flexion could not be confirmed. Conclusions It could be shown, that the pharyngeal diameter is reduced through the contact position implemented by the rider in comparison to the unrestrained head and neck position. An alteration of the pharyngeal diameter depending on the degree of head and neck flexion (represented by ground and withers angle) could not be confirmed. PMID:24886465

  11. Impacts on soils and residual trees from cut-to-length thinning operations in California's redwood forests

    Science.gov (United States)

    Kyungrok Hwang; Han-sup Han; Susan E. Marshall; Deborah S. Page-Dumroese

    2017-01-01

    Cut-to-length (CTL) harvest systems have recently been introduced for thinning third-growth, young (<25 years old) redwood forests (Sequoia sempervirens (Lamb. ex D. Don) Endl.) in northern California. This type of harvesting can effective for thinning overstocked stands consisting of small-diameter trees. However, forestland managers and government agencies...

  12. Length dependence of rectification in organic co-oligomer spin rectifiers

    International Nuclear Information System (INIS)

    Hu Gui-Chao; Zhang Zhao; Li Ying; Ren Jun-Feng; Wang Chuan-Kui

    2016-01-01

    The rectification ratio of organic magnetic co-oligomer diodes is investigated theoretically by changing the molecular length. The results reveal two distinct length dependences of the rectification ratio: for a short molecular diode, the charge-current rectification changes little with the increase of molecular length, while the spin-current rectification is weakened sharply by the length; for a long molecular diode, both the charge-current and spin-current rectification ratios increase quickly with the length. The two kinds of dependence switch at a specific length accompanied with an inversion of the rectifying direction. The molecular ortibals and spin-resolved transmission analysis indicate that the dominant mechanism of rectification suffers a change at this specific length, that is, from asymmetric shift of molecular eigenlevels to asymmetric spatial localization of wave functions upon the reversal of bias. This work demonstrates a feasible way to control the rectification in organic co-oligomer spin diodes by adjusting the molecular length. (paper)

  13. Method of synthesizing small-diameter carbon nanotubes with electron field emission properties

    Science.gov (United States)

    Liu, Jie (Inventor); Du, Chunsheng (Inventor); Qian, Cheng (Inventor); Gao, Bo (Inventor); Qiu, Qi (Inventor); Zhou, Otto Z. (Inventor)

    2009-01-01

    Carbon nanotube material having an outer diameter less than 10 nm and a number of walls less than ten are disclosed. Also disclosed are an electron field emission device including a substrate, an optionally layer of adhesion-promoting layer, and a layer of electron field emission material. The electron field emission material includes a carbon nanotube having a number of concentric graphene shells per tube of from two to ten, an outer diameter from 2 to 8 nm, and a nanotube length greater than 0.1 microns. One method to fabricate carbon nanotubes includes the steps of (a) producing a catalyst containing Fe and Mo supported on MgO powder, (b) using a mixture of hydrogen and carbon containing gas as precursors, and (c) heating the catalyst to a temperature above 950.degree. C. to produce a carbon nanotube. Another method of fabricating an electron field emission cathode includes the steps of (a) synthesizing electron field emission materials containing carbon nanotubes with a number of concentric graphene shells per tube from two to ten, an outer diameter of from 2 to 8 nm, and a length greater than 0.1 microns, (b) dispersing the electron field emission material in a suitable solvent, (c) depositing the electron field emission materials onto a substrate, and (d) annealing the substrate.

  14. Effect of microthreads on coronal bone healing of narrow-diameter implants with reverse-tapered design in beagle dogs.

    Science.gov (United States)

    Chang, Yun-Young; Kim, Su-Hwan; Park, Keun-Oh; Yun, Jeong-Ho

    2017-12-01

    The objective of this study was to investigate the effect of microthreads on the coronal bone healing of narrow-diameter implants with reverse-tapered design. A total of 52 implants were classified into two groups according to presence or absence of coronal microthreads, the reverse-tapered narrow-diameter implant (RTN) group, and the reverse-tapered narrow-diameter implant with microthreads (RTNM) group. The implants were installed in split-mouth design in the edentulous mandible of six dogs. Three animals were sacrificed at 4 weeks and three at 8 weeks. Resonance frequency analysis, bone measurement using microcomputed tomography (micro-CT), removal torque test, and histometric analysis were performed. No significant differences in implant stability quotient value were observed between the groups at baseline, 4 weeks, or 8 weeks. Bone measurement using micro-CT showed that bone-implant contact volume (BICV) and bone-implant contact volume ratio (BICVR) in the coronal part of RTNM were statistically higher than those in RTN at 4 and 8 weeks. Histometric analysis showed statistically higher bone-implant contact length (BICL) in the coronal part of RTNM than in RTN at 4 weeks; however, bone-implant contact ratio (BICR) was not significantly different between the groups. At 8 weeks, the BICL and BICR did not differ significantly between the groups. Removal torque test showed no significant differences between the groups at 4 and 8 weeks. The microthreads might facilitate more coronal bone-implant contact due to increased surface areas at an early healing phase; however, they did not significantly affect coronal bone healing at 8 weeks. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Razão peso/comprimento: um bom indicador do estado nutricional em recém-nascidos a termo? Weight/length ratio: is it a good index to assess the nutritional status of full-term newborns?

    Directory of Open Access Journals (Sweden)

    Taciana D. de A. Braga

    2002-01-01

    Full Text Available Objetivo: uma avaliação acurada do estado nutricional da criança ao nascer tem importância na identificação precoce de eventos mórbidos relacionados com a aceleração ou desaceleração do crescimento intra-útero. Os índices antropométricos resultantes das razões entre o peso e o comprimento e aqueles que resultam da razão entre o perímetro braquial e o perímetro cefálico podem ser uma alternativa, dentro da antropometria, para esse fim. O objetivo principal deste estudo foi verificar o grau de correlação entre a prega cutânea triciptal e os índices antropométricos - índice ponderal de Rohrer, índice de massa corpórea, razão peso/comprimento, razão perímetro braquial/perímetro cefálico - utilizados como critério de avaliação do estado nutricional de recém-nascidos. Métodos: realizou-se um estudo de corte transversal em 390 recém-nascidos a termo na maternidade do Centro de Atenção à Saúde da Mulher do Instituto Materno-Infantil de Pernambuco, no período de maio a julho de 1999. Os recém-nascidos foram avaliados quanto ao peso, comprimento, perímetros cefálico e braquial e prega cutânea triciptal. Resultados: os resultados mostraram que os índices antropométricos apresentaram correlação significante com a prega cutânea triciptal, tendo sido a razão simples entre o peso e o comprimento aquele que se correlacionou mais fortemente (r = 0,63; p Objective: An accurate assessment of the nutritional status of an infant at birth is very important, since it provides information on early identification of pathological events related to intrauterine growth acceleration or retardation. Anthropometric ratios such as weight/length and mid-arm circumference/head circumference may be used as alternative tools for this purpose. The main objective of this study was to verify the correlation between triceps skinfold thickness with Rohrer Index, Body Mass Index, weight/length ratio, and mid-arm circumference

  16. Precise control of multiwall carbon nanotube diameters using thermal chemical vapor deposition

    Science.gov (United States)

    Siegal, M. P.; Overmyer, D. L.; Provencio, P. P.

    2002-03-01

    We grow multiwall carbon nanotube (CNT) films using thermal chemical vapor deposition at atmospheric pressure using a mixture of acetylene and nitrogen from a 4-nm-thick Ni film catalyst. CNTs are characterized using electron microscopy and Rutherford backscattering spectrometry. CNTs grown with this method are extremely uniform in diameter, both throughout the sample and within the lengths of individual tubes. Nanotube outer diameters, ranging from 5-350 nm, and the total deposition of carbon material, increase exponentially with growth temperature from 630 °C-790 °C.

  17. Piezoelectric ultrasonic micromotor with 1.5 mm diameter.

    Science.gov (United States)

    Dong, Shuxiang; Lim, Siak P; Lee, Kwork H; Zhang, Jingdong; Lim, Leong C; Uchino, Kenji

    2003-04-01

    A piezoelectric ultrasonic micromotor has been developed using a lead zirconate titanate (PZT) ceramic/metal composite tube stator that was 1.5 mm in diameter and 7 mm in length. The micromotor was operated in its first bending vibration mode (approximately 70 kHz), producing speeds from hundreds to over 2000 rpm in both rotational directions. The maximum torque-output was 45 microN-m, which is far superior to previous PZT thin film-based micromotors. This micromotor showed good reliability and stability for more than 300 hours of continued operation.

  18. Exploring the limits of case-to-capsule ratio, pulse length, and picket energy for symmetric hohlraum drive on NIF

    Science.gov (United States)

    Callahan, Debra

    2017-10-01

    Over the past two years, we have been exploring low gasfill hohlraums (He fill at 0.3-0.6 mg/cc) as an alternate to the high gasfill hohlraums used in NIC and the High Foot campaigns (He fill at 1-1.6 mg/cc). These low fill hohlraums have significantly reduced laser-plasma instabilities and increased coupling to the target as compared to the high fill hohlraums and take us to a new region of parameter space where the hohlraum is limited by hydrodynamic motion of the hohlraum wall rather than by laser plasma interactions. The outer cone laser beams interacting with the hohlraum wall produce a ``bubble'' of low density, high Z material that moves toward the center of the hohlraum. This gold or depleted uranium bubble eventually intercepts the inner cone beams and prevents the inner cone beams from reaching the waist of the hohlraum-where they are needed to get a symmetric implosion. Thus, the speed of the bubble expansion sets the allowable pulse duration in a given size hohlraum. Data and simulations suggest that the bubble is launched by the early part of the laser pulse (``picket'') and the gold/gas interfaces moves nearly linearly in time toward the axis of the hohlraum. The velocity of the bubble is related to the square root of the energy in the picket of the pulse - thus the picket energy and pulse duration set the allowable hohlraum size and case-to-capsule ratio. In this talk, will discuss a data based model to describe the bubble motion and apply this model to a broad set of data from a variety of ablators (CH, HDC, Be), pulse durations (6-14 ns), case-to-capsule ratios (rhohl/rcap of 3-4.2), hohlraum sizes (5.4-6.7 mm diameter), and hohlraum gasfill densities (0.3-0.6 mg/cc). We will discuss how this model can help guide future designs and how improvements in the hohlraum (foam liners, hohlraum shape) can open up new parts of parameter space. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National

  19. Nearly constant ratio between the proton inertial scale and the spectrum break length scale in the plasma beta range from 0.2 to 1.4 in the solar wind turbulence

    Science.gov (United States)

    Wang, X.; Tu, C. Y.; He, J.; Wang, L.

    2017-12-01

    The spectrum break at the ion scale of the solar wind magnetic fluctuations are considered to give important clue on the turbulence dissipation mechanism. Among several possible mechanisms, the most notable ones are the two mechanisms that related respectively with proton thermal gyro-radius and proton inertial length. However, no definite conclusion has been given for which one is more reasonable because the two parameters have similar values in the normal plasma beta range. Here we do a statistical study for the first time to see if the two mechanism predictions have different dependence on the solar wind velocity and on the plasma beta in the normal plasma beta range in the solar wind at 1 AU. From magnetic measurements by Wind, Ulysses and Messenger, we select 60 data sets with duration longer than 8 hours. We found that the ratio between the proton inertial scale and the spectrum break scale do not change considerably with both varying the solar wind speed from 300km/s to 800km/s and varying the plasma beta from 0.2 to 1.4. The average value of the ratio times 2pi is 0.46 ± 0.08. However, the ratio between the proton gyro-radius and the break scale changes clearly. This new result shows that the proton inertial scale could be a single factor that determines the break length scale and hence gives a strong evidence to support the dissipation mechanism related to it in the normal plasma beta range. The value of the constant ratio may relate with the dissipation mechanism, but it needs further theoretical study to give detailed explanation.

  20. From neural oscillations to reasoning ability: Simulating the effect of the theta-to-gamma cycle length ratio on individual scores in a figural analogy test.

    Science.gov (United States)

    Chuderski, Adam; Andrelczyk, Krzysztof

    2015-02-01

    Several existing computational models of working memory (WM) have predicted a positive relationship (later confirmed empirically) between WM capacity and the individual ratio of theta to gamma oscillatory band lengths. These models assume that each gamma cycle represents one WM object (e.g., a binding of its features), whereas the theta cycle integrates such objects into the maintained list. As WM capacity strongly predicts reasoning, it might be expected that this ratio also predicts performance in reasoning tasks. However, no computational model has yet explained how the differences in the theta-to-gamma ratio found among adult individuals might contribute to their scores on a reasoning test. Here, we propose a novel model of how WM capacity constraints figural analogical reasoning, aimed at explaining inter-individual differences in reasoning scores in terms of the characteristics of oscillatory patterns in the brain. In the model, the gamma cycle encodes the bindings between objects/features and the roles they play in the relations processed. Asynchrony between consecutive gamma cycles results from lateral inhibition between oscillating bindings. Computer simulations showed that achieving the highest WM capacity required reaching the optimal level of inhibition. When too strong, this inhibition eliminated some bindings from WM, whereas, when inhibition was too weak, the bindings became unstable and fell apart or became improperly grouped. The model aptly replicated several empirical effects and the distribution of individual scores, as well as the patterns of correlations found in the 100-people sample attempting the same reasoning task. Most importantly, the model's reasoning performance strongly depended on its theta-to-gamma ratio in same way as the performance of human participants depended on their WM capacity. The data suggest that proper regulation of oscillations in the theta and gamma bands may be crucial for both high WM capacity and effective complex

  1. Relationships between stem diameter at breast height (DBH), tree ...

    African Journals Online (AJOL)

    buba

    amount of light that the tree intercepts for photosynthesis. The tree stem size has its ... the amount of solar radiation intercepted by a tree. (Tanka, 2006). .... 7. Stem Diameter. C ro w n le n g th. Figure 2. Graph of the relationship between stem dbh vs. crown crown length. 0.7. 0.6. 0.5. 0.4. 0.3. 15. 14. 13. 12. 11. 10. 9. 8. 7. 6. 5.

  2. Vertebral Artery Diameter and Flow: Nature or Nurture.

    Science.gov (United States)

    Tarnoki, Adam Domonkos; Fejer, Bence; Tarnoki, David Laszlo; Littvay, Levente; Lucatelli, Pierleone; Cirelli, Carlo; Fanelli, Fabrizio; Sacconi, Beatrice; Fagnani, Corrado; Medda, Emanuela; Farina, Filippo; Meneghetti, Giorgio; Horvath, Tamas; Pucci, Giacomo; Schillaci, Giuseppe; Stazi, Maria Antonietta; Baracchini, Claudio

    2017-09-01

    In contrast with the carotid arteries, the vertebral arteries (VAs) show considerable variation in length, caliber, and vessel course. This study investigated whether the variation in diameter and flow characteristics of the VAs might be inherited. A total of 172 Italian twins from Padua, Perugia, and Terni (54 monozygotic, 32 dizygotic) recruited from the Italian Twin Registry underwent B-mode and pulsed-wave Doppler ultrasound assessment of their VAs. VA diameters, peak systolic velocity (PSV) and end diastolic velocity (EDV) were assessed at the level of a horizontal V2 segment. Univariate quantitative genetic modeling was performed. Fourteen percent of the sample had VA hypoplasia. Within pair correlation in monozygotic twins was higher than in dizygotics (.552 vs. .229) for VA diameter. Age- and sex-adjusted genetic effect, under the most parsimonious model, accounted for 54.7% (95% CI: 42.2-69.1%) of the variance of VA diameter, and unshared environmental effect for 45.3% (95% CI: 30.9-57.8%). No heritability was found for the PSV of VA, but shared (34.1%; 95% CI: 16.7-53.7%) and unshared (65.9%; 95% CI: 45.9-83.1%) environmental factors determined the variance. EDV of VA is moderately genetically influenced (42.4%; 95% CI: 16.1-64.9%) and also determined by the unshared environment (57.6%; 95% CI: 34.7-83.7%). The diameter of the VAs is moderately genetically determined. Different factors influence the PSV and EDV of VAs, which may highlight the complex hemodynamic background of VA flow and help to understand the vertebral flow anomalies found by ultrasound. Copyright © 2017 by the American Society of Neuroimaging.

  3. A study on boiling heat transfer with mixture boiling from vertical rod fin

    International Nuclear Information System (INIS)

    Kim, M.C.

    1981-01-01

    The purpose of the present study is concerned with the boiling characteristic of variations of the length-diameter ratio on the heat transfer rate where the nucleate boiling and natural convection occurred simultaneously. Circular fins were made with copper rod 32 mm in diameter, and those surfaces were mirror finished. The length-diameter ratio was varied 1 to 6. As a boiling liquid, the distilled water was used in this experiment. The results of this experiment were obtained as below. 1) From the observations, it was confirmed that nucleate boiling and natural convection occurred simultaneously. 2) As the length-diameter ratio increased, the boiling heat transfer rate also augmented. (author)

  4. Ultrasonographic Measurement of the Diameter of a Normal Bile Duct, Hepatic Artery and Portal Vein in Infants Younger Than 3 Months

    International Nuclear Information System (INIS)

    Kim, Sang Yoon; Lee, Young Seok

    2009-01-01

    This study focused on measuring the diameter of the normal bile duct, hepatic artery and portal vein with high resolution US in infants younger than 3 months, and we wanted to determine the relative ratio of these diameters. Fifty US examinations were performed on infants younger than 3 months and who did not have any clinical or laboratory abnormality associated with the hepatobiliary system. We measured the diameter of the bile duct, hepatic artery and portal vein at the level of the portal vein bifurcation with using 17-5 MHz US and we determined the relative ratios of these diameters. To evaluate the statistical difference in the diameter of the bile duct, hepatic artery and portal vein, we performed one-way ANOVA and Scheffe's multiple comparison test. To determine the relative ratio of these diameters, the ratio of the bile duct to the hepatic artery was defined as the hepatic artery/bile duct, the ratio of the hepatic artery to the portal vein was defined as the portal vein/hepatic artery and the ratio of the bile duct to the portal vein was defined as the portal vein/bile duct. We calculated the averages ± standard deviations of this data (minimum ∼ maximum). In all fifty infants, the bile duct, hepatic artery and portal vein were detectable and measurable. The average diameter of a bile duct was 0.85 ± 0.19 mm (0.56 ∼ 1.47 mm), it was 1.33 ± 0.31 mm (0.90 ∼ 2.37 mm) for the hepatic artery and 3.32 ± 0.68 mm (2.06 ∼ 5.08 mm) for the portal vein. The diameter of these structures was significantly different from each other according to one-way ANOVA (p < 0.001). The average diameter of the hepatic artery was significantly larger than that of the bile duct and the average diameter of the portal vein was significantly larger than that of bile duct and hepatic artery on Scheffe's multiple comparison test. The relative ratio of the bile duct to the hepatic artery was 1.60 ± 0.41 (0.77 ∼ 2.66), that of the hepatic artery to the portal vein was 2

  5. Gas phase synthesis of non-bundled, small diameter single-walled carbon nanotubes with near-armchair chiralities

    Energy Technology Data Exchange (ETDEWEB)

    Mustonen, K.; Laiho, P.; Kaskela, A.; Zhu, Z.; Reynaud, O.; Houbenov, N.; Tian, Y.; Jiang, H.; Kauppinen, E. I., E-mail: esko.kauppinen@aalto.fi [Department of Applied Physics, Aalto University School of Science, P.O. Box 15100, FI-00076 Aalto (Finland); Susi, T. [Faculty of Physics, University of Vienna, Boltzmanngasse 5, A-1090 Vienna (Austria); Nasibulin, A. G. [Department of Applied Physics, Aalto University School of Science, P.O. Box 15100, FI-00076 Aalto (Finland); Skolkovo Institute of Science and Technology, Nobel str. 3, 143026 (Russian Federation); Saint-Petersburg State Polytechnical University, 29 Polytechniheskaya st., St. Petersburg, 195251 (Russian Federation)

    2015-07-06

    We present a floating catalyst synthesis route for individual, i.e., non-bundled, small diameter single-walled carbon nanotubes (SWCNTs) with a narrow chiral angle distribution peaking at high chiralities near the armchair species. An ex situ spark discharge generator was used to form iron particles with geometric number mean diameters of 3–4 nm and fed into a laminar flow chemical vapour deposition reactor for the continuous synthesis of long and high-quality SWCNTs from ambient pressure carbon monoxide. The intensity ratio of G/D peaks in Raman spectra up to 48 and mean tube lengths up to 4 μm were observed. The chiral distributions, as directly determined by electron diffraction in the transmission electron microscope, clustered around the (n,m) indices (7,6), (8,6), (8,7), and (9,6), with up to 70% of tubes having chiral angles over 20°. The mean diameter of SWCNTs was reduced from 1.10 to 1.04 nm by decreasing the growth temperature from 880 to 750 °C, which simultaneously increased the fraction of semiconducting tubes from 67% to 80%. Limiting the nanotube gas phase number concentration to ∼10{sup 5 }cm{sup −3} prevented nanotube bundle formation that is due to collisions induced by Brownian diffusion. Up to 80% of 500 as-deposited tubes observed by atomic force and transmission electron microscopy were individual. Transparent conducting films deposited from these SWCNTs exhibited record low sheet resistances of 63 Ω/□ at 90% transparency for 550 nm light.

  6. A new method for measuring coronary artery diameters with CT spatial profile curves

    International Nuclear Information System (INIS)

    Shimamoto, Ryoichi; Suzuki, Jun-ichi; Yamazaki, Tadashi; Tsuji, Taeko; Ohmoto, Yuki; Morita, Toshihiro; Yamashita, Hiroshi; Honye, Junko; Nagai, Ryozo; Akahane, Masaaki; Ohtomo, Kuni

    2007-01-01

    Purpose: Coronary artery vascular edge recognition on computed tomography (CT) angiograms is influenced by window parameters. A noninvasive method for vascular edge recognition independent of window setting with use of multi-detector row CT was contrived and its feasibility and accuracy were estimated by intravascular ultrasound (IVUS). Methods: Multi-detector row CT was performed to obtain 29 CT spatial profile curves by setting a line cursor across short-axis coronary angiograms processed by multi-planar reconstruction. IVUS was also performed to determine the reference coronary diameter. IVUS diameter was fitted horizontally between two points on the upward and downward slopes of the profile curves and Hounsfield number was measured at the fitted level to test seven candidate indexes for definition of intravascular coronary diameter. The best index from the curves should show the best agreement with IVUS diameter. Results: Of the seven candidates the agreement was the best (agreement: 16 ± 11%) when the two ratios of Hounsfield number at the level of IVUS diameter over that at the peak on the profile curves were used with water and with fat as the background tissue. These edge definitions were achieved by cutting the horizontal distance by the curves at the level defined by the ratio of 0.41 for water background and 0.57 for fat background. Conclusions: Vascular edge recognition of the coronary artery with CT spatial profile curves was feasible and the contrived method could define the coronary diameter with reasonable agreement

  7. Diameter Tuning of β-Ga2O3 Nanowires Using Chemical Vapor Deposition Technique.

    Science.gov (United States)

    Kumar, Mukesh; Kumar, Vikram; Singh, R

    2017-12-01

    Diameter tuning of [Formula: see text]-Ga 2 O 3 nanowires using chemical vapor deposition technique have been investigated under various experimental conditions. Diameter of root grown [Formula: see text]-Ga 2 O 3 nanowires having monoclinic crystal structure is tuned by varying separation distance between metal source and substrate. Effect of gas flow rate and mixer ratio on the morphology and diameter of nanowires has been studied. Nanowire diameter depends on growth temperature, and it is independent of catalyst nanoparticle size at higher growth temperature (850-900 °C) as compared to lower growth temperature (800 °C). These nanowires show changes in structural strain value with change in diameter. Band-gap of nanowires increases with decrease in the diameter.

  8. Fabrication of large diameter alumino-silicate K+ sources

    International Nuclear Information System (INIS)

    Baca, D.; Chacon-Golcher, E.; Kwan, J.W.; Wu, J.K.

    2003-01-01

    Alumino-silicate K + sources have been used in HIF experiments for many years. For example the Neutralized Transport Expt. (NTX) and the High Current Transport Expt. (HCX) are now using this type of ion source with diameters of 2.54 cm and 10 cm respectively. These sources have demonstrated ion currents of 80 mA and 700 mA, for typical HIF pulse lengths of 5-10 (micro)s. The corresponding current density is ∼ 10-15 mA/cm 2 , but much higher current density has been observed using smaller size sources. Recently we have improved our fabrication techniques and, therefore, are able to reliably produce large diameter ion sources with high quality emitter surface without defects. This note provides a detailed description of the procedures employed in the fabrication process. The variables in the processing steps affecting surface quality, such as substrate porosity, powder size distribution, coating technique on large area concave surfaces, drying, and heat firing temperature have been investigated

  9. Validity of using modified capillary column with larger diameter to study the Cs diffusion in local Taiwan laterite

    International Nuclear Information System (INIS)

    Tsing-Hai Wang; National Tsing Hua University, Hsinchu, Taiwan; Wen-Chun Yeh; Shih-Chin Tsai; Yi-Lin Jan; Shi-Ping Teng

    2008-01-01

    We have examined the working diameter of capillary columns with diameter of 5, 7, 10 and 20 mm. These modified capillary columns were carefully filled with local Taiwan laterite (LTL). The porosity and density of these packed columns was 0.51±0.02 g/g and 1.27±0.05 g/cm 3 , respectively. The diffusion experiments were then carried out in synthetic groundwater with Cs loading of 0.1mM at room temperature. Experimental results have shown that the diffusion profiles of modified capillary columns fit Fick's second law very well. This result revealed that the working diameter of a capillary column can be expanded to at least to 20 mm without affecting the validity of the derived diffusion coefficients. Among these columns, the ones with 5 mm diameter show the most consistent results of the derived K d , apparent and effective diffusion coefficients. Although the derived distribution and effective diffusion coefficients slightly decrease as the diameter of these columns increases due to the increase of the solid/liquid ratio. These values are still informative of the Cs diffusion in local Taiwan laterite. Moreover, our results clearly demonstrate the potential of using 'modified capillary method' to study the diffusion behaviors of concerned radionuclide because columns with large diameter enable the filling with more versatile geological substances. (author)

  10. Assessment of the Nucleus-to-Cytoplasmic Ratio in MCF-7 Cells Using Ultra-high Frequency Ultrasound and Photoacoustics

    Science.gov (United States)

    Moore, M. J.; Strohm, E. M.; Kolios, M. C.

    2016-12-01

    The nucleus-to-cytoplasmic (N:C) ratio of a cell is often used when assessing histology for the presence of malignant disease. In this proof of concept study, we present a new, non-optical method for determination of the N:C ratio using ultra-high Frequency ultrasound (US) and photoacoustics (PA). When using transducers in the 100 MHz-500 MHz range, backscattered US pulses and emitted PA waves are encoded with information pertaining to the dimension and morphology of micron-sized objects. If biological cells are interrogated, the diameter of the scattering or absorbing structure can be assessed by fitting the power spectra of the measured US or PA signals to theoretical models for US backscatter and PA emission from a fluid sphere. In this study, the cell and nucleus diameters of 9 MCF-7 breast cancer cells were determined using a new simplified model that calculates the theoretical values of the location of the power spectra minima for both US and PA signals. These diameters were then used to calculate the N:C ratio of the measured cells. The average cell diameter determined by US pulses from a transducer with a central frequency of 375 MHz was found to be 15.5 μ m± 1.8 μ m. The PA waves emitted by the cell nuclei were used to determine an average nuclear diameter of 12.0 μ m± 1.3 μ m. The N:C ratio for these cells was calculated to be 1.9± 1.0, which agrees well with previously reported N:C values for this cell type.

  11. Effect of aspect ratio on the uptake and toxicity of hydroxylated-multi walled carbon nanotubes in the nematode,

    Directory of Open Access Journals (Sweden)

    Hyun-Jeong Eom

    2015-03-01

    Full Text Available Objectives In this study, the effect of tube length and outer diameter (OD size of hydroxylated-multi walled carbon nanotubes (OH-MWCNTs on their uptake and toxicity was investigated in the nematode Caenorhabditis elegans using a functional mutant analysis. Methods The physicochemical properties of three different OH-MWCNTs were characterized. Uptake and toxicity were subsequently investigated on C. elegans exposed to MWCNTs with different ODs and tube lengths. Results The results of mutant analysis suggest that ingestion is the main route of MWCNTs uptake. We found that OH-MWCNTs with smaller ODs were more toxic than those with larger ODs, and OH-MWCNTs with shorter tube lengths were more toxic than longer counterparts to C. elegans. Conclusions Overall the results suggest the aspect ratio affects the toxicity of MWCNTs in C. elegans. Further thorough study on the relationship between physicochemical properties and toxicity needs to be conducted for more comprehensive understanding of the uptake and toxicity of MWCNTs.

  12. Dynamic response of the U-tube liquid manometer with equal diameter columns

    International Nuclear Information System (INIS)

    Zahariea, D

    2010-01-01

    The paper presents numerical solving methods using MATLAB programming language of the governing equation of the liquid oscillations in a U-tube liquid manometer with equal diameter columns. Assuming some numerical values for geometrical and functional parameters of this pressure measurement system, the dynamic behavior of the oscillating system will be analyzed using four MATLAB based computational methods: the method of the default MATLAB procedures, the Simulink method, the Simscape method and the method of the Control System Toolbox procedures. According to all these methods, in almost all the cases analyzed, the dynamic behavior of the U-tube liquid manometer with equal diameter columns corresponds to an under-damped dynamic system. The influence of some important constructive and functional parameters (the columns diameter, the manometer liquid, the capillarity action and the connection tube between the reservoir and the manometer) has been investigated. Improving the dynamic response (decreasing the overshoot and the settling time, increasing the phase and delay margins) can be achieved by increasing the connection tube length, by decreasing the columns diameter and by using a high density liquid manometer.

  13. Numerical evaluation of droplet sizing based on the ratio of fluorescent and scattered light intensities (LIF/Mie technique)

    International Nuclear Information System (INIS)

    Charalampous, Georgios; Hardalupas, Yannis

    2011-01-01

    The dependence of fluorescent and scattered light intensities from spherical droplets on droplet diameter was evaluated using Mie theory. The emphasis is on the evaluation of droplet sizing, based on the ratio of laser-induced fluorescence and scattered light intensities (LIF/Mie technique). A parametric study is presented, which includes the effects of scattering angle, the real part of the refractive index and the dye concentration in the liquid (determining the imaginary part of the refractive index). The assumption that the fluorescent and scattered light intensities are proportional to the volume and surface area of the droplets for accurate sizing measurements is not generally valid. More accurate sizing measurements can be performed with minimal dye concentration in the liquid and by collecting light at a scattering angle of 60 deg. rather than the commonly used angle of 90 deg. Unfavorable to the sizing accuracy are oscillations of the scattered light intensity with droplet diameter that are profound at the sidescatter direction (90 deg.) and for droplets with refractive indices around 1.4.

  14. Synthesis of subnanometer-diameter vertically aligned single-walled carbon nanotubes with copper-anchored cobalt catalysts

    Science.gov (United States)

    Cui, Kehang; Kumamoto, Akihito; Xiang, Rong; An, Hua; Wang, Benjamin; Inoue, Taiki; Chiashi, Shohei; Ikuhara, Yuichi; Maruyama, Shigeo

    2016-01-01

    We synthesize vertically aligned single-walled carbon nanotubes (VA-SWNTs) with subnanometer diameters on quartz (and SiO2/Si) substrates by alcohol CVD using Cu-anchored Co catalysts. The uniform VA-SWNTs with a nanotube diameter of 1 nm are synthesized at a CVD temperature of 800 °C and have a thickness of several tens of μm. The diameter of SWNTs was reduced to 0.75 nm at 650 °C with the G/D ratio maintained above 24. Scanning transmission electron microscopy energy-dispersive X-ray spectroscopy (EDS-STEM) and high angle annular dark field (HAADF-STEM) imaging of the Co/Cu bimetallic catalyst system showed that Co catalysts were captured and anchored by adjacent Cu nanoparticles, and thus were prevented from coalescing into a larger size, which contributed to the small diameter of SWNTs. The correlation between the catalyst size and the SWNT diameter was experimentally clarified. The subnanometer-diameter and high-quality SWNTs are expected to pave the way to replace silicon for next-generation optoelectronic and photovoltaic devices.We synthesize vertically aligned single-walled carbon nanotubes (VA-SWNTs) with subnanometer diameters on quartz (and SiO2/Si) substrates by alcohol CVD using Cu-anchored Co catalysts. The uniform VA-SWNTs with a nanotube diameter of 1 nm are synthesized at a CVD temperature of 800 °C and have a thickness of several tens of μm. The diameter of SWNTs was reduced to 0.75 nm at 650 °C with the G/D ratio maintained above 24. Scanning transmission electron microscopy energy-dispersive X-ray spectroscopy (EDS-STEM) and high angle annular dark field (HAADF-STEM) imaging of the Co/Cu bimetallic catalyst system showed that Co catalysts were captured and anchored by adjacent Cu nanoparticles, and thus were prevented from coalescing into a larger size, which contributed to the small diameter of SWNTs. The correlation between the catalyst size and the SWNT diameter was experimentally clarified. The subnanometer-diameter and high

  15. Problems of cleaning the large diameter sections of deep wells

    Energy Technology Data Exchange (ETDEWEB)

    Patsch, F; Gilicz, B

    1966-01-01

    In drilling deep wells, great importance is being given to the problem of cutting removal from the hole bottom of sections drilled by large diameter bits. The length of borehole sections drilled by 12-1/4-in. and larger bits has been more than doubled in Hungary in the course of the past 4 years. When the drilling fluid jet is struck against the borehole bottom, pressure waves are brought about which take on a crossed flow pattern and result in a retardation of cleaning of the well bottom, particularly in the case of larger bottom surfaces. In large diameter boreholes, the cleaning efficiency is being achieved by full utilization of the pump power and increased pump delivery. Friction losses in drill pipes are being reduced by using 6-in. XH pipes.

  16. The population distribution of the sagittal abdominal diameter (SAD) and SAD/height ratio among Finnish adults.

    Science.gov (United States)

    Kahn, H S; Rissanen, H; Bullard, K M; Knekt, P

    2014-12-01

    Sagittal abdominal diameter (SAD; 'abdominal height' measured in supine position) may improve upon conventional anthropometry for predicting incident cardiometabolic diseases. However, the SAD is used infrequently by practitioners and epidemiologists. A representative survey of Finnish adults in 2000-2001 collected body measurements including SAD (by sliding-beam calliper) using standardized protocols. Sampled non-pregnant adults (ages 30+ years; 79% participation) provided 6123 SAD measurements from 80 health centre districts. Through stratified, complex survey design, these data represented 2.86 million adults at ages 30+ years. SAD ranged from 13.5 to 38.0 cm, with a population mean (standard error) of 21.7 (0.05) cm and median (interquartile range) of 21.0 (19.1-23.4). Median SAD was higher at ages 50+ years compared with ages 30-49 both for men (22.4 [20.5-24.6] vs. 20.8 [19.3-22.7]) and women (21.7 [19.6-23.9] vs. 19.4 [17.8-21.4]). The SAD/height ratio was similar (0.118) for both sexes at 30-39 years, rising more steeply with age for women than men. Attaining only a basic education, compared with a high level, was associated with increased mean (95% confidence interval) SADs for men (22.6 [22.3-22.8] vs. 22.0 [21.7-22.2]) and women (21.8 [21.5-22.0] vs. 20.6 [20.4-20.8]). Finland's early experience with nationally representative SAD measurements provides normative reference values and physiological insights useful for investigations of cardiometabolic risk. © 2014 World Obesity.

  17. Perception of Length to Width Relations of City Squares

    Directory of Open Access Journals (Sweden)

    Harold T. Nefs

    2013-04-01

    Full Text Available In this paper, we focus on how people perceive the aspect ratio of city squares. Earlier research has focused on distance perception but not so much on the perceived aspect ratio of the surrounding space. Furthermore, those studies have focused on “open” spaces rather than urban areas enclosed by walls, houses and filled with people, cars, etc. In two experiments, we therefore measured, using a direct and an indirect method, the perceived aspect ratio of five city squares in the historic city center of Delft, the Netherlands. We also evaluated whether the perceived aspect ratio of city squares was affected by the position of the observer on the square. In the first experiment, participants were asked to set the aspect ratio of a small rectangle such that it matched the perceived aspect ratio of the city square. In the second experiment, participants were asked to estimate the length and width of the city square separately. In the first experiment, we found that the perceived aspect ratio was in general lower than the physical aspect ratio. However, in the second experiment, we found that the calculated ratios were close to veridical except for the most elongated city square. We conclude therefore that the outcome depends on how the measurements are performed. Furthermore, although indirect measurements are nearly veridical, the perceived aspect ratio is an underestimation of the physical aspect ratio when measured in a direct way. Moreover, the perceived aspect ratio also depends on the location of the observer. These results may be beneficial to the design of large open urban environments, and in particular to rectangular city squares.

  18. Engineering of an E. coli outer membrane protein FhuA with increased channel diameter

    Directory of Open Access Journals (Sweden)

    Dworeck Tamara

    2011-08-01

    Full Text Available Abstract Background Channel proteins like FhuA can be an alternative to artificial chemically synthesized nanopores. To reach such goals, channel proteins must be flexible enough to be modified in their geometry, i.e. length and diameter. As continuation of a previous study in which we addressed the lengthening of the channel, here we report the increasing of the channel diameter by genetic engineering. Results The FhuA Δ1-159 diameter increase has been obtained by doubling the amino acid sequence of the first two N-terminal β-strands, resulting in variant FhuA Δ1-159 Exp. The total number of β-strands increased from 22 to 24 and the channel surface area is expected to increase by ~16%. The secondary structure analysis by circular dichroism (CD spectroscopy shows a high β-sheet content, suggesting the correct folding of FhuA Δ1-159 Exp. To further prove the FhuA Δ1-159 Exp channel functionality, kinetic measurement using the HRP-TMB assay (HRP = Horse Radish Peroxidase, TMB = 3,3',5,5'-tetramethylbenzidine were conducted. The results indicated a 17% faster diffusion kinetic for FhuA Δ1-159 Exp as compared to FhuA Δ1-159, well correlated to the expected channel surface area increase of ~16%. Conclusion In this study using a simple "semi rational" approach the FhuA Δ1-159 diameter was enlarged. By combining the actual results with the previous ones on the FhuA Δ1-159 lengthening a new set of synthetic nanochannels with desired lengths and diameters can be produced, broadening the FhuA Δ1-159 applications. As large scale protein production is possible our approach can give a contribution to nanochannel industrial applications.

  19. Low-energy electron transmission through high aspect ratio Al O nanocapillaries

    DEFF Research Database (Denmark)

    Milosavljević, A.R.; Jureta, J.; Víkor, G.

    2009-01-01

    Electron transmission through insulating AlO nanocapillaries of different diameters (40 and 270 nm) and 15 μm length has been investigated for low-energy electrons (2-120 V). The total intensity of transmitted current weakly depends on the incident electron energy and tilt angle defined with resp......Electron transmission through insulating AlO nanocapillaries of different diameters (40 and 270 nm) and 15 μm length has been investigated for low-energy electrons (2-120 V). The total intensity of transmitted current weakly depends on the incident electron energy and tilt angle defined...

  20. Fabrication of high aspect ratio micro electrode by using EDM

    International Nuclear Information System (INIS)

    Elsiti, Nagwa Mejid; Noordin, M.Y.; Alkali, Adam Umar

    2016-01-01

    The electrical discharge machining (EDM) process inherits characteristics that make it a promising micro-machining technique. Micro electrical discharge machining (micro- EDM) is a derived form of EDM, which is commonly used to manufacture micro and miniature parts and components by using the conventional electrical discharge machining fundamentals. Moving block electro discharge grinding (Moving BEDG) is one of the processes that can be used to fabricate micro-electrode. In this study, a conventional die sinker EDM machine was used to fabricate the micro-electrode. Modifications are made to the moving BEDG, which include changing the direction of movements and control gap in one electrode. Consequently current was controlled due to the use of roughing, semi-finishing and finishing parameters. Finally, a high aspect ratio micro-electrode with a diameter of 110.49μm and length of 6000μm was fabricated. (paper)

  1. Models for mean bonding length, melting point and lattice thermal expansion of nanoparticle materials

    International Nuclear Information System (INIS)

    Omar, M.S.

    2012-01-01

    Graphical abstract: Three models are derived to explain the nanoparticles size dependence of mean bonding length, melting temperature and lattice thermal expansion applied on Sn, Si and Au. The following figures are shown as an example for Sn nanoparticles indicates hilly applicable models for nanoparticles radius larger than 3 nm. Highlights: ► A model for a size dependent mean bonding length is derived. ► The size dependent melting point of nanoparticles is modified. ► The bulk model for lattice thermal expansion is successfully used on nanoparticles. -- Abstract: A model, based on the ratio number of surface atoms to that of its internal, is derived to calculate the size dependence of lattice volume of nanoscaled materials. The model is applied to Si, Sn and Au nanoparticles. For Si, that the lattice volume is increases from 20 Å 3 for bulk to 57 Å 3 for a 2 nm size nanocrystals. A model, for calculating melting point of nanoscaled materials, is modified by considering the effect of lattice volume. A good approach of calculating size-dependent melting point begins from the bulk state down to about 2 nm diameter nanoparticle. Both values of lattice volume and melting point obtained for nanosized materials are used to calculate lattice thermal expansion by using a formula applicable for tetrahedral semiconductors. Results for Si, change from 3.7 × 10 −6 K −1 for a bulk crystal down to a minimum value of 0.1 × 10 −6 K −1 for a 6 nm diameter nanoparticle.

  2. Models for mean bonding length, melting point and lattice thermal expansion of nanoparticle materials

    Energy Technology Data Exchange (ETDEWEB)

    Omar, M.S., E-mail: dr_m_s_omar@yahoo.com [Department of Physics, College of Science, University of Salahaddin-Erbil, Arbil, Kurdistan (Iraq)

    2012-11-15

    Graphical abstract: Three models are derived to explain the nanoparticles size dependence of mean bonding length, melting temperature and lattice thermal expansion applied on Sn, Si and Au. The following figures are shown as an example for Sn nanoparticles indicates hilly applicable models for nanoparticles radius larger than 3 nm. Highlights: ► A model for a size dependent mean bonding length is derived. ► The size dependent melting point of nanoparticles is modified. ► The bulk model for lattice thermal expansion is successfully used on nanoparticles. -- Abstract: A model, based on the ratio number of surface atoms to that of its internal, is derived to calculate the size dependence of lattice volume of nanoscaled materials. The model is applied to Si, Sn and Au nanoparticles. For Si, that the lattice volume is increases from 20 Å{sup 3} for bulk to 57 Å{sup 3} for a 2 nm size nanocrystals. A model, for calculating melting point of nanoscaled materials, is modified by considering the effect of lattice volume. A good approach of calculating size-dependent melting point begins from the bulk state down to about 2 nm diameter nanoparticle. Both values of lattice volume and melting point obtained for nanosized materials are used to calculate lattice thermal expansion by using a formula applicable for tetrahedral semiconductors. Results for Si, change from 3.7 × 10{sup −6} K{sup −1} for a bulk crystal down to a minimum value of 0.1 × 10{sup −6} K{sup −1} for a 6 nm diameter nanoparticle.

  3. Effect of Process Parameters on Flow Length and Flash Formation in Injection Moulding of High Aspect Ratio Polymeric Micro Features

    Directory of Open Access Journals (Sweden)

    Abdelkhalik Eladl

    2018-01-01

    Full Text Available This paper reports an investigation of the effects of process parameters on the quality characteristics of polymeric parts produced by micro injection moulding (μIM with two different materials. Four injection moulding process parameters (injection velocity, holding pressure, melt temperature and mould temperature were investigated using Polypropylene (PP and Acrylonitrile Butadiene Styrene (ABS. Three key characteristics of the mouldings were evaluated with respect to process settings and the material employed: part mass, flow length and flash formation. The experimentation employs a test part with four micro fingers with different aspect ratios (from 21 up to 150 and was carried out according to the Design of Experiments (DOE statistical technique. The results show that holding pressure and injection velocity are the most influential parameters on part mass with a direct effect for both materials. Both parameters have a similar effect on flow length for both PP and ABS at all aspect ratios and have higher effects as the feature thickness decreased below 300 μm. The study shows that for the investigated materials the injection speed and packing pressure were the most influential parameters for increasing the amount of flash formation, with relative effects consistent for both materials. Higher melt and mould temperatures settings were less influential parameters for increasing the flash amount when moulding with both materials. Of the two investigated materials, PP was the one exhibiting more flash formation as compared with ABS, when corresponding injection moulding parameters settings for both materials were considered.

  4. Database for Pressure Tube Diameter and Operation Data of Wolsong NPP

    International Nuclear Information System (INIS)

    Jung, Jong Yeob; Kim, W. Y.; Bae, J. H.; Park, J. H.

    2010-12-01

    Pressure tube of CANDU reactor which is a long cylindrical shape of its diameter about 10 cm and length of about 6m, can be expanded toward both radial and axial directions due to irradiation under the high pressure and temperature condition. As the irradiation period increases, the radial expansion due to creep of the pressure tube increases. The radial expansion of the pressure tube comes out the reduction of the coolability and it results in the power deration. The objectives of the current work is to establish the database for the measured diametral data of pressure tube and operational data from Wolsong NPP as a preliminary work of developing the prediction model for pressure tube diameter. In order to develop the database, measured data for total 86 channels were collected from Wolsong NPP 1, 2, 3 and 4 and analyzed. Based on the provided data, the operational conditions such as an axial temperature and a pressure of the channel and neutron fluxes were derived. All data were analysed to derive the correlation between the pressure tube diameter and the other operational parameters

  5. CoFe2O4 nanoparticles as a catalyst: synthesis of a forest of vertically aligned CNTs of uniform diameters by plasma-enhanced CVD

    International Nuclear Information System (INIS)

    Baliyan, Ankur; Fukuda, Takahiro; Hayasaki, Yasuhiro; Uchida, Takashi; Nakajima, Yoshikata; Hanajiri, Tatsuro; Maekawa, Toru

    2013-01-01

    Controlling actively the structures of carbon nanotubes such as the alignment, length, diameter, chirality and the number of walls still remains a crucial challenge. The properties of CNTs are highly structure sensitive and particularly dependent on the diameter and number of walls. In this brief communication, we synthesise monodisperse CoFe 2 O 4 nanoparticles of uniform diameters, i.e. 4.8 and 6.9 nm, which are modified with oleic acid as a catalyst for the growth of CNTs. We show that a forest of vertically aligned CNTs of uniform diameters and lengths can be grown using CoFe 2 O 4 nanoparticles. The internal diameters and lengths of CNTs grown using CoFe 2 O 4 nanoparticles of 4.8 and 6.9 nm diameters are, respectively, 4.4 and 6.2 nm and 10 and 15 μm. It is clearly shown that the number of walls of CNTs can be engineered changing the materials of the catalytic nanoparticles. The present results may well encourage further systematic studies on the growth of CNTs using various combinations of elements for the catalytic nanoparticles under different external conditions, which may provide not only the possibilities of controlling the properties of CNTs but also an insight into the nucleation and growth mechanisms.

  6. Failure Diameter Resolution Study

    Energy Technology Data Exchange (ETDEWEB)

    Menikoff, Ralph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-12-19

    Previously the SURFplus reactive burn model was calibrated for the TATB based explosive PBX 9502. The calibration was based on fitting Pop plot data, the failure diameter and the limiting detonation speed, and curvature effect data for small curvature. The model failure diameter is determined utilizing 2-D simulations of an unconfined rate stick to find the minimum diameter for which a detonation wave propagates. Here we examine the effect of mesh resolution on an unconfined rate stick with a diameter (10mm) slightly greater than the measured failure diameter (8 to 9 mm).

  7. Numerical analysis of ion temperature effects to the plasma wall transition using a one-dimensional two-fluid model. I. Finite Debye to ionization length ratio

    Science.gov (United States)

    Gyergyek, T.; Kovačič, J.

    2017-06-01

    A one-dimensional, two-fluid, steady state model is used for the analysis of ion temperature effects to the plasma-wall transition. In this paper, the model is solved for a finite ratio ɛ between the Debye and the ionization length, while in Part II [T. Gyergyek and J. Kovačič, Phys Plasmas 24, 063506 (2017)], the solutions for ɛ = 0 are presented. Ion temperature is treated as a given, independent parameter and it is included in the model as a boundary condition. It is shown that when the ion temperature larger than zero is selected, the ion flow velocity and the electric field at the boundary must be consistent with the selected ion temperature. A numerical procedure, how to determine such "consistent boundary conditions," is proposed, and a simple relation between the ion temperature and ion velocity at the boundary of the system is found. The effects of the ion temperature to the pre-sheath length, potential, ion temperature, and ion density drops in the pre-sheath and in the sheath are investigated. It is concluded that larger ion temperature results in a better shielding of the plasma from the wall. An attempt is made to include the ion heat flux qi into the model in its simplest form q i = - K ' /d T i d x , where K ' is a constant heat conduction coefficient. It is shown that inclusion of such a term into the energy transfer equation introduces an additional ion heating mechanism into the system and the ion flow then becomes isothermal instead of adiabatic even in the sheath.

  8. Numerical Evaluation on the Different Shapes of Gravelly Sand Columns to Increase the Loading Capacity of Soft Clay

    Directory of Open Access Journals (Sweden)

    Meghzili Sif Allah

    2017-01-01

    Full Text Available Improvement on soft clay by the installation of stone column is one of the most popular methods followed worldwide. Different analytical and numerical solutions have already been developed for understanding the load transfer mechanism of soft soil reinforced with stone column. This study investigated a bearing capacity of the gravelly sand column, installed in soft clay bed at 15kpa of undrained shear strength. The column variable of length and diameter ratio at 7, 8 and 9 were evaluated. On top of that, the combination of two diameters in single column was tested and the uniform diameter was used as a control. In the numerical analysis, Mohrcoulomb model was adopted in the idealization of the behaviour of the gravelly sand column and soft clay materials. The results revealed that the optimum design that gave the highest loading capacity of the combination 11=12 of column diameter was the length and diameter ratio of 8.

  9. Reducing Length of Stay in Total Joint Arthroplasty Care.

    Science.gov (United States)

    Walters, Megan; Chambers, Monique C; Sayeed, Zain; Anoushiravani, Afshin A; El-Othmani, Mouhanad M; Saleh, Khaled J

    2016-10-01

    As health care reforms continue to improve quality of care, significant emphasis will be placed on evaluation of orthopedic patient outcomes. Total joint arthroplasty (TJA) has a proven track record of enhancing patient quality of life and are easily replicable. The outcomes of these procedures serve as a measure of health care initiative success. Specifically, length of stay, will be targeted as a marker of quality of surgical care delivered to TJA patients. Within this review, we will discuss preoperative and postoperative methods by which orthopedic surgeons may enhance TJA outcomes and effectively reduce length of stay. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Factors related to axial length elongation and myopia progression in orthokeratology practice.

    Directory of Open Access Journals (Sweden)

    Bingjie Wang

    Full Text Available To investigate which baseline factors are predictive for axial length growth over an average period of 2.5 years in a group of children wearing orthokeratology (OK contact lenses.In this retrospective study, the clinical records of 249 new OK wearers between January 2012 and December 2013 from the contact lens clinic at the Eye and ENT Hospital of Fudan University were reviewed. The primary outcome measure was axial length change from baseline to the time of review (July-August 2015. Independent variables included baseline measures of age at initiation of OK wear, gender, refractive error (spherical equivalent, astigmatism, average keratometry, corneal toricity, central corneal thickness, white-to-white corneal diameter, pupil size, corneal topography eccentricity value (e-value, intraocular pressure (IOP and total time in follow-up (months total. The contributions of all independent variables on axial length change at the time of review were assessed using univariate and multivariable regression analyses.Univariate analyses of the right eyes of 249 OK patients showed that smaller increases in axial length were associated with older age at the onset of OK lens wear, greater baseline spherical equivalent myopic refractive error, less time in follow-up and a smaller e-value. Multivariable analyses of the significant right eye variables showed that the factors associated with smaller axial length growth were older age at the onset of OK lens wear (p<0.0001, greater baseline spherical equivalent myopic refractive error (p = 0.0046 and less time in follow-up (p<0.0001.The baseline factors demonstrating the greatest correlation with reduced axial length elongation during OK lens wear in myopic children included greater baseline spherical equivalent myopic refractive error and older age at the onset of OK lens wear.

  11. Automated estimation of abdominal effective diameter for body size normalization of CT dose.

    Science.gov (United States)

    Cheng, Phillip M

    2013-06-01

    Most CT dose data aggregation methods do not currently adjust dose values for patient size. This work proposes a simple heuristic for reliably computing an effective diameter of a patient from an abdominal CT image. Evaluation of this method on 106 patients scanned on Philips Brilliance 64 and Brilliance Big Bore scanners demonstrates close correspondence between computed and manually measured patient effective diameters, with a mean absolute error of 1.0 cm (error range +2.2 to -0.4 cm). This level of correspondence was also demonstrated for 60 patients on Siemens, General Electric, and Toshiba scanners. A calculated effective diameter in the middle slice of an abdominal CT study was found to be a close approximation of the mean calculated effective diameter for the study, with a mean absolute error of approximately 1.0 cm (error range +3.5 to -2.2 cm). Furthermore, the mean absolute error for an adjusted mean volume computed tomography dose index (CTDIvol) using a mid-study calculated effective diameter, versus a mean per-slice adjusted CTDIvol based on the calculated effective diameter of each slice, was 0.59 mGy (error range 1.64 to -3.12 mGy). These results are used to calculate approximate normalized dose length product values in an abdominal CT dose database of 12,506 studies.

  12. Ultrasonographically determined renal values and comparisons to serum biochemistry renal variables in aged semi-captive cheetahs (Acinonyx jubatus).

    Science.gov (United States)

    Kirberger, Robert M; Tordiffe, Adrian S W

    2017-11-06

    Cheetahs in captivity have a high prevalence of chronic renal diseases. We ultrasonographically evaluated the renal volumes, a variety of renal dimensions, interarcuate artery resistive indices (RI) as well as aortic diameters and the length of the ventral aspect of the 6th lumbar vertebrae in 27 aged semi-captive anesthetized cheetahs. Renal size, dimensions and ratios were compared to urine specific gravity, serum creatinine and urea values. There were minimal differences for all values between left and right kidneys. Mean kidney length was 65.1 mm (range 55.2-76.9) with left kidney length ratios to L6 length being 1.60 (range 1.27-2.06) and to the aortic diameter 7.69 (range 4.54-10.72). Significant correlations between left renal length as well as length:L6 ratio to creatinine values were found ((r - 0.66) and (r - 0.60) respectively). The mean RI values of the different sedation/anesthetic protocols ranged from 0.46-0.55. Left renal length and L6 ventral vertebral body length as well as left kidney RI values should be routinely measured in all cheetah abdominal ultrasound examinations. These measurements, together with serum creatinine, urea and urine specific gravity values may be relatively sensitive indicators of early renal pathology in the absence of gross ultrasonographic changes.

  13. Femur length and biparietal diameter

    African Journals Online (AJOL)

    2014-12-02

    Dec 2, 2014 ... A regression model for prediction of fetal age using the fetal biometry was also deduced ... done using a linear array real time ultrasound machine. Siemens Sonoline 1 with a 3.5 MHz transducer. ... values were regressed on GA using a simple linear equation. (y = a + b × GA). The 3rd, 5th, 10th, 50th, 90th, ...

  14. Effect of location and diameter of the branch in three genotypes of Myrciaria dubia (HBK "camu camu" for vegetative propagation by air layering

    Directory of Open Access Journals (Sweden)

    Jiang Oliver Liao Torres

    2012-09-01

    Full Text Available The objective of this study was to evaluate the effect of the location and diameter of the branch in three genotypes of camu camu using the technique of air layering on rooting and sprouting. The mother plants were bent and then rooted branches were transplanted following the design of randomized complete block with three replications. At 3 months after transplantation was the assessment of the variables, finding the best values for the number of roots to the middle third, thick diameter, Genotype MD-015 and the upper, thick diameter, Genotype MD-015 with 28.67 and 28.33 roots, respectively, in the variable length of the upper third roots, thick diameter, Genotype MD-015 showed the best results with 15.27 cm. Regarding the number of outbreaks upper, thick diameter, Genotype MD-014 and the upper, thick diameter, Genotype MD-015 achieved the best results with 13.00 and 12.67 outbreaks, respectively, in the length of shoots, the best treatment was the upper, thick diameter, Genotype MD-015 with 30.73 cm, and finally in the variable number of leaves / shoot highlights the upper, thick diameter, Genotype MD-014 and the upper, thick diameter, Genotype MD-015 with 15.10 leaves per shoot and 14.83, respectively. The results allowed identifying the upper, thick diameter, Genotype MD-015 as the best in terms of rooting and sprouting capacity.

  15. Chemoattractive capacity of different lengths of nerve fragments bridging regeneration chambers for the repair of sciatic nerve defects

    Institute of Scientific and Technical Information of China (English)

    Jiren Zhang; Yubo Wang; Jincheng Zhang

    2012-01-01

    A preliminary study by our research group showed that 6-mm-long regeneration chamber bridging is equivalent to autologous nerve transplantation for the repair of 12-mm nerve defects.In this study,we compared the efficacy of different lengths (6,8,10 mm) of nerve fragments bridging 6-mm regeneration chambers for the repair of 12-mm-long nerve defects.At 16 weeks after the regeneration chamber was implanted,the number,diameter and myelin sheath thickness of the regenerated nerve fibers,as well as the conduction velocity of the sciatic nerve and gastrocnemius muscle wet weight ratio,were similar to that observed with autologous nerve transplantation.Our results demonstrate that 6-,8-and 10-mm-long nerve fragments bridging 6-mm regeneration chambers effectively repair 12-mm-long nerve defects.Because the chemoattractive capacity is not affected by the length of the nerve fragment,we suggest adopting 6-mm-long nerve fragments for the repair of peripheral nerve defects.

  16. Evaluation of a cut-to-length system implementing fuel reduction treatments on the Coconino National Forest in Arizona

    Science.gov (United States)

    John Klepac; Bob Rummer; Jason Thompson

    2006-01-01

    A Cut-to-Length (CTL) system was evaluated for production and cost while implementing fuel reduction treatments in two stands on the Coconino National Forest in Arizona. Product recovery and fire behavior within each stand after treatment were also examined. Only trees less than 16 inches diameter breast height (DBH) were harvested. After logs were forwarded to a...

  17. A 2.5-mm diameter probe for photoacoustic and ultrasonic endoscopy.

    Science.gov (United States)

    Yang, Joon-Mo; Chen, Ruimin; Favazza, Christopher; Yao, Junjie; Li, Chiye; Hu, Zhilin; Zhou, Qifa; Shung, K Kirk; Wang, Lihong V

    2012-10-08

    We have created a 2.5-mm outer diameter integrated photo-acoustic and ultrasonic mini-probe which can be inserted into a standard video endoscope's instrument channel. A small-diameter focused ultrasonic transducer made of PMN-PT provides adequate signal sensitivity, and enables miniaturization of the probe. Additionally, this new endoscopic probe utilizes the same scanning mirror and micromotor-based built-in actuator described in our previous reports; however, the length of the rigid distal section of the new probe has been further reduced to ~35 mm. This paper describes the technical details of the mini-probe and presents experimental results that both quantify the imaging performance and demonstrate its in vivo imaging capability, which suggests that it could work as a mini-probe for certain clinical applications.

  18. A 2.5-mm diameter probe for photoacoustic and ultrasonic endoscopy

    Science.gov (United States)

    Yang, Joon-Mo; Chen, Ruimin; Favazza, Christopher; Yao, Junjie; Li, Chiye; Hu, Zhilin; Zhou, Qifa; Shung, K. Kirk; Wang, Lihong V.

    2012-01-01

    We have created a 2.5-mm outer diameter integrated photo-acoustic and ultrasonic mini-probe which can be inserted into a standard video endoscope’s instrument channel. A small-diameter focused ultrasonic transducer made of PMN-PT provides adequate signal sensitivity, and enables miniaturization of the probe. Additionally, this new endoscopic probe utilizes the same scanning mirror and micromotor-based built-in actuator described in our previous reports; however, the length of the rigid distal section of the new probe has been further reduced to ~35 mm. This paper describes the technical details of the mini-probe and presents experimental results that both quantify the imaging performance and demonstrate its in vivo imaging capability, which suggests that it could work as a mini-probe for certain clinical applications. PMID:23188360

  19. Wide-diameter locking-taper implants: a prospective clinical study with 1 to 10-year follow-up

    Directory of Open Access Journals (Sweden)

    C. Mangano

    2014-06-01

    Full Text Available Aim: Wide-diameter implants (WDIs, diameter ≥4.5 mm are increasingly being used in patients with poor bone quality and reduced bone height. The aim of this study was to evaluate the survival rate, peri-implant bone loss, biological and prosthetic complications of wide-diameter (4.8 mm locking-taper implants used in the restoration of partially and fully edentulous patients. Materials and methods: Between January 2002 and December 2011, all patients referred to a private clinic for treatment with WDIs were considered for inclusion in the study. At each annual follow-up session, clinical and radiographic parameters were assessed: the outcome measurements were implant failure, peri-implant bone loss (distance between the implant shoulder and the first visible bone-to-implant contact: DIB, biological and prosthetic complications. The cumulative survival rate (CSR was assessed using the Kaplan-Meier estimator; Log-rank was applied to evaluate correlations between the study variables. The statistical analysis was performed at the patient and at the implant level. Results: A total of 438 WDIs were placed in 411 patients. Four implants failed, for a CSR of 99% (patient-based and 99.1% (implant-based at 10-year follow-up. The CSR did not differ significantly with respect to patients’ gender, age, smoking or parafunctional habit, implant location, position, length, bone type or prosthetic restoration. A mean DIB of 0.34 mm (± 0.23, 0.45 mm (± 0.27 and 0.75 mm (± 0.33 was shown at the 1-, 5- and 10-year follow-up examination. Conclusions: Wide-diameter, locking-taper implants can be a good treatment option for the rehabilitation of partially and fully edentulous patients over the long term.

  20. Investigation of strut-ramp injector in a Scramjet combustor: Effect of strut geometry, fuel and jet diameter on mixing characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Soni, Rahul Kumar; De, Ashoke De [Indian Institute of Technology Kanpur, Kanpur (India)

    2017-03-15

    The strut-based injector has been found to be one of the most promising injector designs for a supersonic combustor, offering enhanced mixing of fuel and air. The mixing and flow field characteristics of the straight (SS) and Tapered strut (TS), with fixed ramp angle and height at free stream Mach number 2 in conjunction with fuel injection at Mach 2.3 have been investigated numerically and reported. In the present investigation, hydrogen (H{sub 2}) and ethylene (C{sub 2}H{sub 4}) are injected in oncoming supersonic flow from the back of the strut, where jet to free stream momentum ratio is maintained at 0.79 and 0.69 for H2 and C{sub 2}H{sub 4}, respectively. The predicted wall static pressure and species mole fractions at various downstream locations are compared with the experimental data for TS case with 0.6 mm jet diameter and found to be in good agreement. Further, the effect of jet diameter and strut geometry on the near field mixing in strut ramp configuration is discussed for both the fuels. The numerical results are assessed based on various parameters for the performance evaluation of different strut ramp configurations. The SS configuration for both the injectant has been found to be an optimum candidate; also it is observed that for higher jet diameter larger combustor length is required to achieve satisfactory near field mixing.

  1. Copolymers of N-cyclohexylacrylamide and n-butyl acrylate: synthesis, characterization, monomer reactivity ratios and mean sequence length

    Directory of Open Access Journals (Sweden)

    2007-06-01

    Full Text Available Copolymerization of N-cyclohexylacrylamide (NCHA and n-butyl acrylate (BA was carried out in dimethylformamide at 55±1°C using azobisisobutyronitrile as a free radical initiator. The copolymers were characterized by 1H-NMR spectroscopy and the copolymer compositions were determined by 1H-NMR analysis. The reactivity ratios of the monomers were determined by both linear and non-linear methods. The reactivity ratios of monomers determined using linear methods like Fineman-Ross (r1 = 0.37 and r2 = 1.77 , Kelen-Tudos (r1 = 0.38 and r2 = 1.77, ext. Kelen-Tudos (r1 = 0.37 and r2 = 1.75 Yezrieler-Brokhina-Roskin (r1 = 0.37 and r2 = 1.77 and non-linear methods like Tidwell-Mortimer (r1 = 0.37 and r2 = 1.76, ProCop (r1 = 0.36 and r2 = 1.82. The Q and e values for NCHA are 0.67 and 0.68 respectively. Mean sequence lengths of copolymers are estimated from r1 and r2 values. It shows that the BA units increases in a linear fashion in the polymer chain as the concentration of BA increases in the monomer feed.

  2. Variation in the Growth Traits and Wood Properties of Chinese Fir from Six Provinces of Southern China

    Directory of Open Access Journals (Sweden)

    Hongjing Duan

    2016-08-01

    Full Text Available To determine the phenotypic variation in 700 ten-year grafted Chinese fir collected from six provinces in southern China, 10 phenotypic traits were investigated: tree height, diameter at breast height, bark thickness, volume of timber, heartwood ratio, density of wood, hygroscopicity, tracheid length, tracheid diameter, and ratio of tracheid length to tracheid diameter. Abundant phenotypic variation was found among the six populations; the phenotypic variation coefficients all exceeded 10%, and the largest was for volume of timber. Significant variation (p < 0.01 or 0.05 in traits was found among the populations, except for diameter at breast height, heartwood ratio, and tracheid diameter, while all traits differed significantly (p < 0.01 within populations. The high value of repeatability (broad-sense heritability suggested moderate genetic control of the traits. The 10 traits were strongly correlated within the entire population; strong positive correlations (p < 0.01 were observed between growth traits, and significant negative correlations (p < 0.01 or 0.05 were found between the density of wood and most other characteristics, except for heartwood ratio and ratio of tracheid length to tracheid diameter. Using diameter at breast height and density of wood as criteria, 98 relatively fast-growing genotypes with relatively high wood basic density were identified.

  3. Three-dimensional diffraction of a thin metallic cylinder illuminated in conical incidence: application to diameter estimation

    International Nuclear Information System (INIS)

    Miguel Sanchez-Brea, Luis; Javier Salgado-Remacha, Francisco

    2008-01-01

    We present a model to determine the far-field diffraction pattern of a metallic cylinder of infinite length when it is illuminated in oblique incidence. This model is based on the Helmholtz-Kirchhoff integral using the Beckmann conditions for reflection. It considers the three-dimensional nature of the diffracting object as well as the material of which the cylinder is made. This model shows that the diffraction orders are placed in a cone of light. The amplitude at the far field can be divided into three terms: the first term accounts for Babinet's principle, that is, the contribution of the cylinder projection; the second term accounts for the three dimensionality of the cylinder; and the third term accounts for the material of which the cylinder is made. This model is applied to the diameter estimation of the cylinder. Since the amplitude of the Babinet contribution is much larger than the light reflected by the surface, the cylinder diameter can be obtained in a simple way. With this approximation, the locations of the diffraction minima do not vary when the cylinder is inclined. On the other hand, when the reflected light is considered the location of the minima and, hence, the estimation of the diameter, varies. Also, a modification of the diffraction minima is produced by the material of which the cylinder is made. Experimental results are also obtained that corroborate the theoretical approach

  4. Effect of axial length on laser spot size during photodynamic therapy: an experimental study in monkeys.

    Science.gov (United States)

    Kondo, Mineo; Ito, Yasuki; Miyata, Kentaro; Kondo, Nagako; Ishikawa, Kohei; Terasaki, Hiroko

    2006-01-01

    To investigate the effect of shorter axial length on the laser spot size and laser energy during photodynamic therapy (PDT) in monkeys. Experimental study with four rhesus monkeys. PDT was performed on the normal retina of monkeys whose ocular axial lengths are shorter (19.55 to 20.25 mm) than that of humans. After the PDT, the eyes were enucleated, and the diameter of the irradiated laser spot was measured with a microcaliper. The area of actual laser spot was only 0.56 to 0.61 times of the planned area, which indicated that the laser energy/area was 1.64 to 1.78 times more intense than planned initially. These results are the in vivo demonstration that the diameter of PDT laser spot is smaller for eyes with shorter axial lengths.

  5. Sagittal Abdominal Diameter: Application in Clinical Practice

    Directory of Open Access Journals (Sweden)

    Thaís Da Silva-Ferreira

    2014-05-01

    Full Text Available Excess visceral fat is associated with cardiovascular risk factors. Sagittal abdominal diameter (SAD has recently been highlighted as an indicator of abdominal obesity, and also may be useful in predicting cardiovascular risk. The purpose of the present study was to review the scientific literature on the use of SAD in adult nutritional assessment. A search was conducted for scientific articles in the following electronic databases: SciELO , MEDLINE (PubMed and Virtual Health Library. SAD is more associated with abdominal fat (especially visceral, and with different cardiovascular risk factors, such as, insulin resistance, blood pressure, and serum lipoproteins than the traditional methods of estimating adiposity, such as body mass index and waist-to-hip ratio. SAD can also be used in association with other anthropometric measures. There are still no cut-off limits established to classify SAD as yet. SAD can be an alternative measure to estimate visceral adiposity. However, the few studies on this diameter, and the lack of consensus on the anatomical site to measure SAD, are obstacles to establish cut-off limits to classify it.

  6. Strong diameter-dependence of nanowire emission coupled to waveguide modes

    Energy Technology Data Exchange (ETDEWEB)

    Dam, Dick van, E-mail: a.d.v.dam@tue.nl; Haverkort, Jos E. M. [Department of Applied Physics, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven (Netherlands); Abujetas, Diego R.; Sánchez-Gil, José A. [Instituto de Estructura de la Materia (IEM-CSIC), Consejo Superior de Investigaciones Científicas Serrano, 121, 28006 Madrid (Spain); Bakkers, Erik P. A. M. [Department of Applied Physics, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven (Netherlands); Kavli Institute of Nanoscience, Delft University of Technology, Lorentzweg 1, 2628 CJ Delft (Netherlands); Gómez Rivas, Jaime, E-mail: j.gomezrivas@differ.nl [Department of Applied Physics, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven (Netherlands); Dutch Institute for Fundamental Energy Research DIFFER, P.O. Box 6336, 5600 HH Eindhoven (Netherlands)

    2016-03-21

    The emission from nanowires can couple to waveguide modes supported by the nanowire geometry, thus governing the far-field angular pattern. To investigate the geometry-induced coupling of the emission to waveguide modes, we acquire Fourier microscopy images of the photoluminescence of nanowires with diameters ranging from 143 to 208 nm. From the investigated diameter range, we conclude that a few nanometers difference in diameter can abruptly change the coupling of the emission to a specific mode. Moreover, we observe a diameter-dependent width of the Gaussian-shaped angular pattern in the far-field emission. This dependence is understood in terms of interference of the guided modes, which emit at the end facets of the nanowire. Our results are important for the design of quantum emitters, solid state lighting, and photovoltaic devices based on nanowires.

  7. Numerical study of two side-by-side cylinders with unequal diameters at low Reynolds number

    International Nuclear Information System (INIS)

    Gao, Y Y; Wang, X K; Tan, S K

    2012-01-01

    Two-dimensional laminar flow about two side-by-side unequal cylinders with different diameter ratios d/D and centre-to-centre spacing ratios T/D at Re=300 (based on the larger cylinder diameter) was simulated using a CFD software. Comparisons of experimental and numerical results were made to elucidate the degree of interference due to d/D and T/D and their effects on the flow patterns and vortex shedding frequencies. The findings showed that the flow patterns behind two unequal cylinders were distinctly different from that behind two equal side-by-side cylinders, with distinct in-phase and anti-phase vortex shedding, and random switching of modes of vortex shedding.

  8. Experimental analysis of heat conduction in a high diameter ratio annular gap filled with a rarefied gas

    International Nuclear Information System (INIS)

    Chalabi, H; Lorenzini, M; Morini, G L; Saraceno, L; Boccardi, G; Celata, G P

    2012-01-01

    A first experimental attempt has been realized in order to measure the heat transfer between a heated platinum wire having a diameter (d) of 0.15 mm, disposed along the axis of a cylindrical shell in stainless steel having an inner diameter (D) of 100 mm, and air from atmospheric conditions down to 10 −3 mbar. Temperature differences between the wire and the external stainless steel cylindrical shell in the range of 50–125 K were imposed and the heat power transferred from the wire to the surround was measured as a function of the gas pressure. The experimental results demonstrates that for an accurate measurement of the heat conduction when the pressure goes down to 0.05 mbar is very important to be able to quantify accurately the radiative contribution which becomes predominant at low pressure. The main limitations of the test rig described in this paper have been analysed in order to highlight the modifications which can be suggested to obtain experimental results comparable with theoretical models.

  9. Using a relational database to improve mortality and length of stay for a department of surgery: a comparative review of 5200 patients.

    Science.gov (United States)

    Ang, Darwin N; Behrns, Kevin E

    2013-07-01

    The emphasis on high-quality care has spawned the development of quality programs, most of which focus on broad outcome measures across a diverse group of providers. Our aim was to investigate the clinical outcomes for a department of surgery with multiple service lines of patient care using a relational database. Mortality, length of stay (LOS), patient safety indicators (PSIs), and hospital-acquired conditions were examined for each service line. Expected values for mortality and LOS were derived from University HealthSystem Consortium regression models, whereas expected values for PSIs were derived from Agency for Healthcare Research and Quality regression models. Overall, 5200 patients were evaluated from the months of January through May of both 2011 (n = 2550) and 2012 (n = 2650). The overall observed-to-expected (O/E) ratio of mortality improved from 1.03 to 0.92. The overall O/E ratio for LOS improved from 0.92 to 0.89. PSIs that predicted mortality included postoperative sepsis (O/E:1.89), postoperative respiratory failure (O/E:1.83), postoperative metabolic derangement (O/E:1.81), and postoperative deep vein thrombosis or pulmonary embolus (O/E:1.8). Mortality and LOS can be improved by using a relational database with outcomes reported to specific service lines. Service line quality can be influenced by distribution of frequent reports, group meetings, and service line-directed interventions.

  10. Does the index-to-ring finger length ratio (2D:4D) differ in amyotrophic lateral sclerosis (ALS)? Results from an international online case-control study.

    Science.gov (United States)

    Parkin Kullmann, Jane Alana; Pamphlett, Roger

    2017-08-07

    The ratio of the length of the index finger (2D) to the ring finger (4D) (2D:4D) has been reported to be lower (ie, 2Dcontrols. This has led to suggestions that exposure to increased prenatal testosterone, which also lowers this ratio, could be a risk factor for ALS. In an attempt to test this hypothesis, we examined 2D:4Ds from large numbers of patients with ALS and controls. An online multilingual questionnaire enabling respondents to measure their own index and ring finger lengths. Of the initial 949 respondents, 572 remained for analysis after elimination for inability to straighten fingers, not answering the question, statistical outliers and aged controls (112 males, 258 females). Unpaired t-tests with 95% CIs were used to assess differences in mean 2D:4Ds. Males had significantly lower mean 2D:4Ds than females, in both ALS and control groups, for both left and right hands. No significant differences were found in 2D:4Ds between ALS and control groups, in either males or females, for either left or right hands. Receiver operating characteristic curves showed no power for 2D:4Ds to predict ALS status in either males or females. 2D:4Ds did not differ between patients with ALS and controls in this study. This was despite the dataset being large enough to confirm the established finding of lower 2D:4Ds in males compared with females. These findings do not support the hypothesis that exposure to increased prenatal testosterone is a risk factor for ALS. A putative lower 2D:4D has been proposed to explain the link between ALS and exercise, but our results indicate that other exercise-related factors are more likely to explain this association. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  11. WE-EF-207-06: Dedicated Cone-Beam Breast CT with Laterally-Shifted Detector: Monte Carlo Evaluation of X-Ray Scatter Distribution and Scatter-To-Primary Ratio

    International Nuclear Information System (INIS)

    Shi, L; Vedantham, S; Karellas, A

    2015-01-01

    Purpose: To determine the spatial distribution of x-ray scatter and scatter-to-primary ratio (SPR) in projections during cone-beam breast CT (CBBCT) with laterally-shifted detector that results in coronal (fan-angle) truncation. Methods: We hypothesized that CBBCT with coronal truncation would lower SPR due to reduction in irradiated breast volume, and that the location of maximum x-ray scatter fluence (scatter-peak) in the detector plane can be determined from the ratio of irradiated-to-total breast volume, breast dimensions and system geometry. Monte Carlo simulations (GEANT4) reflecting a prototype CBBCT system were used to record the position-dependent primary and scatter x-ray photon fluence incident on the detector without coronal truncation (full fan-angle, 2f=24-degrees) and with coronal truncation (fan-angle, f+ f=12+2.7-degrees). Semi-ellipsoidal breasts (10/14/18-cm diameter, chest-wall to nipple length: 0.75xdiameter, 2%/14%/100% fibroglandular content) aligned with the axis-of-rotation (AOR) were modeled. Mono-energy photons were simulated and weighted for 2 spectra (49kVp, 1.4-mm Al HVL; 60kVp, 3.76-mm Al HVL). In addition to SPR, the scatter maps were analyzed to identify the location of the scatter-peak. Results: For CBBCT without fan-angle truncation, the scatter-peaks were aligned with the projection of the AOR onto the detector for all breasts. With truncated fan-beam, the scatter-peaks were laterally-shifted from the projection of the AOR along the fan-angle direction by 14/38/70-pixels for 10/14/18-cm diameter breasts. The corresponding theoretical shifts were 14.8/39.7/68-pixels (p=0.47, 2-tailed paired-ratio t-test). Along the cone-angle, the shift in scatter-peaks between truncated and full-fan angle CBBCT were 2/2/4 -pixels for 10/14/18-cm diameter breasts. CBBCT with fan-angle truncation reduced SPR by 14/22/28% for 10/14/18-cm diameter breasts. 60kVp reduced SPR by 21–25% compared to 49kVp. Peak SPR for CBBCT with fan-angle truncation

  12. Tannins gravimetric yield condensed in Anadenanthera peregrina bark in different diameter classes

    Directory of Open Access Journals (Sweden)

    Caroline Junqueira Sartori

    2014-06-01

    Full Text Available This work aimed to determine the gravimetric yield of condensed tannins in the Anadenanthera peregrina bark in different diameter classes. Fifty-nine trees samples were collected of Anadenanthera peregrina, at 1.30m of the ground (diameter at breast height - DBH, distributed in seven diameter classes. The barks were dried and crushed in mill of hammer. Composite sample was made to prepare the extract. The extraction was done using water in the ratio 15:1 (v/w, added 3% sodium sulfite (w/w in water-bath at 70°C for 4 hours. The material was filtered using fine cloth strainer and concentrated on a heating plate at approximately 150 g. It was determined the extract mass and removed 10 g for obtaining solids content and 20g for the Stiasny's index. The average values of total solids content, Stiasny's index, condensed tannin content and the compound content non-tannin were 11.34%; 75.79%; 12.76% and 4.07%, respectively. The content of solids, Stiasny's index, compound content non-tannin show significant differences between diameter classes. For the condensed tannins production, the diameter class parameter there was no influence.

  13. Optimizing parameter of particle damping based on Leidenfrost effect of particle flows

    Science.gov (United States)

    Lei, Xiaofei; Wu, Chengjun; Chen, Peng

    2018-05-01

    Particle damping (PD) has strongly nonlinearity. With sufficiently vigorous vibration conditions, it always plays excellent damping performance and the particles which are filled into cavity are on Leidenfrost state considered in particle flow theory. For investigating the interesting phenomenon, the damping effect of PD on this state is discussed by the developed numerical model which is established based on principle of gas and solid. Furtherly, the numerical model is reformed and applied to study the relationship of Leidenfrost velocity with characteristic parameters of PD such as particle density, diameter, mass packing ratio and diameter-length ratio. The results indicate that particle density and mass packing ratio can drastically improve the damping performance as opposed as particle diameter and diameter-length ratio, mass packing ratio and diameter-length ratio can low the excited intensity for Leidenfrost state. For discussing the application of the phenomenon in engineering, bound optimization by quadratic approximation (BOBYQA) method is employed to optimize mass packing ratio of PD for minimize maximum amplitude (MMA) and minimize total vibration level (MTVL). It is noted that the particle damping can drastically reduce the vibrating amplitude for MMA as Leidenfrost velocity equal to the vibrating velocity relative to maximum vibration amplitude. For MTVL, larger mass packing ratio is best option because particles at relatively wide frequency range is adjacent to Leidenfrost state.

  14. Effect of repetitive pecking at working length for glide path preparation using G-file

    Directory of Open Access Journals (Sweden)

    Jung-Hong Ha

    2015-05-01

    Full Text Available Objectives Glide path preparation is recommended to reduce torsional failure of nickel-titanium (NiTi rotary instruments and to prevent root canal transportation. This study evaluated whether the repetitive insertions of G-files to the working length maintain the apical size as well as provide sufficient lumen as a glide path for subsequent instrumentation. Materials and Methods The G-file system (Micro-Mega composed of G1 and G2 files for glide path preparation was used with the J-shaped, simulated resin canals. After inserting a G1 file twice, a G2 file was inserted to the working length 1, 4, 7, or 10 times for four each experimental group, respectively (n = 10. Then the canals were cleaned by copious irrigation, and lubricated with a separating gel medium. Canal replicas were made using silicone impression material, and the diameter of the replicas was measured at working length (D0 and 1 mm level (D1 under a scanning electron microscope. Data was analysed by one-way ANOVA and post-hoc tests (p = 0.05. Results The diameter at D0 level did not show any significant difference between the 1, 2, 4, and 10 times of repetitive pecking insertions of G2 files at working length. However, 10 times of pecking motion with G2 file resulted in significantly larger canal diameter at D1 (p < 0.05. Conclusions Under the limitations of this study, the repetitive insertion of a G2 file up to 10 times at working length created an adequate lumen for subsequent apical shaping with other rotary files bigger than International Organization for Standardization (ISO size 20, without apical transportation at D0 level.

  15. Administrative license suspension: Does length of suspension matter?

    Science.gov (United States)

    Fell, James C; Scherer, Michael

    2017-08-18

    Administrative license revocation (ALR) laws, which provide that the license of a driver with a blood alcohol concentration at or over the illegal limit is subject to an immediate suspension by the state department of motor vehicles, are an example of a traffic law in which the sanction rapidly follows the offense. The power of ALR laws has been attributed to how swiftly the sanction is applied, but does the length of suspension matter? Our objectives were to (a) determine the relationship of the ALR suspension length to the prevalence of drinking drivers relative to sober drivers in fatal crashes and (b) estimate the extent to which the relationship is associated to the general deterrent effect compared to the specific deterrent effect of the law. Data comparing the impact of ALR law implementation and ALR law suspension periods were analyzed using structural equation modeling techniques on the ratio of drinking drivers to nondrinking drivers in fatal crashes from the Fatality Analysis Reporting System (FARS). States with an ALR law with a short suspension period (1-30 days) had a significantly lower drinking driver ratio than states with no ALR law. States with a suspension period of 91-180 days had significantly lower ratios than states with shorter suspension periods, while the three states with suspension lengths of 181 days or longer had significantly lower ratios than states with shorter suspension periods. The implementation of any ALR law was associated with a 13.1% decrease in the drinking/nondrinking driver fatal crash ratio but only a 1.8% decrease in the intoxicated/nonintoxicated fatal crash ratio. The ALR laws and suspension lengths had a significant general deterrent effect, but no specific deterrent effect. States might want to keep (or adopt) ALR laws for their general deterrent effects and pursue alternatives for specific deterrent effects. States with short ALR suspension periods should consider lengthening them to 91 days or longer.

  16. Magnetic alloy nanowire arrays with different lengths: Insights into the crossover angle of magnetization reversal process

    Energy Technology Data Exchange (ETDEWEB)

    Samanifar, S.; Alikhani, M. [Department of Physics, University of Kashan, Kashan 87317-51167 (Iran, Islamic Republic of); Almasi Kashi, M., E-mail: almac@kashanu.ac.ir [Department of Physics, University of Kashan, Kashan 87317-51167 (Iran, Islamic Republic of); Institute of Nanoscience and Nanotechnology, University of Kashan, Kashan 87317-51167 (Iran, Islamic Republic of); Ramazani, A. [Department of Physics, University of Kashan, Kashan 87317-51167 (Iran, Islamic Republic of); Institute of Nanoscience and Nanotechnology, University of Kashan, Kashan 87317-51167 (Iran, Islamic Republic of); Montazer, A.H. [Institute of Nanoscience and Nanotechnology, University of Kashan, Kashan 87317-51167 (Iran, Islamic Republic of)

    2017-05-15

    Nanoscale magnetic alloy wires are being actively investigated, providing fundamental insights into tuning properties in magnetic data storage and processing technologies. However, previous studies give trivial information about the crossover angle of magnetization reversal process in alloy nanowires (NWs). Here, magnetic alloy NW arrays with different compositions, composed of Fe, Co and Ni have been electrochemically deposited into hard-anodic aluminum oxide templates with a pore diameter of approximately 150 nm. Under optimized conditions of alumina barrier layer and deposition bath concentrations, the resulting alloy NWs with aspect ratio and saturation magnetization (M{sub s}) up to 550 and 1900 emu cm{sup −3}, respectively, are systematically investigated in terms of composition, crystalline structure and magnetic properties. Using angular dependence of coercivity extracted from hysteresis loops, the reversal processes are evaluated, indicating non-monotonic behavior. The crossover angle (θ{sub c}) is found to depend on NW length and M{sub s}. At a constant M{sub s}, increasing NW length decreases θ{sub c}, thereby decreasing the involvement of vortex mode during the magnetization reversal process. On the other hand, decreasing M{sub s} decreases θ{sub c} in large aspect ratio (>300) alloy NWs. Phenomenologically, it is newly found that increasing Ni content in the composition decreases θ{sub c}. The angular first-order reversal curve (AFORC) measurements including the irreversibility of magnetization are also investigated to gain a more detailed insight into θ{sub c}. - Highlights: • Magnetic alloy NWs with aspect ratios up to 550 were fabricated into hard-AAO templates. • Morphology, composition, crystal structure and magnetic properties were investigated. • Angular dependence of coercivity was used to describe the magnetization reversal process. • The crossover angle of magnetization reversal was found to depend on NW length and M{sub s}.

  17. CoFe{sub 2}O{sub 4} nanoparticles as a catalyst: synthesis of a forest of vertically aligned CNTs of uniform diameters by plasma-enhanced CVD

    Energy Technology Data Exchange (ETDEWEB)

    Baliyan, Ankur [Graduate School of Interdisciplinary New Science, Toyo University (Japan); Fukuda, Takahiro [Bio-Nano Electronics Research Centre, Toyo University (Japan); Hayasaki, Yasuhiro; Uchida, Takashi; Nakajima, Yoshikata; Hanajiri, Tatsuro; Maekawa, Toru, E-mail: maekawa@toyo.jp [Graduate School of Interdisciplinary New Science, Toyo University (Japan)

    2013-06-15

    Controlling actively the structures of carbon nanotubes such as the alignment, length, diameter, chirality and the number of walls still remains a crucial challenge. The properties of CNTs are highly structure sensitive and particularly dependent on the diameter and number of walls. In this brief communication, we synthesise monodisperse CoFe{sub 2}O{sub 4} nanoparticles of uniform diameters, i.e. 4.8 and 6.9 nm, which are modified with oleic acid as a catalyst for the growth of CNTs. We show that a forest of vertically aligned CNTs of uniform diameters and lengths can be grown using CoFe{sub 2}O{sub 4} nanoparticles. The internal diameters and lengths of CNTs grown using CoFe{sub 2}O{sub 4} nanoparticles of 4.8 and 6.9 nm diameters are, respectively, 4.4 and 6.2 nm and 10 and 15 {mu}m. It is clearly shown that the number of walls of CNTs can be engineered changing the materials of the catalytic nanoparticles. The present results may well encourage further systematic studies on the growth of CNTs using various combinations of elements for the catalytic nanoparticles under different external conditions, which may provide not only the possibilities of controlling the properties of CNTs but also an insight into the nucleation and growth mechanisms.

  18. Amplitude-independent flaw length determination using differential eddy current

    Science.gov (United States)

    Shell, E.

    2013-01-01

    Military engine component manufacturers typically specify the eddy current (EC) inspection requirements as a crack length or depth with the assumption that the cracks in both the test specimens and inspected component are of a similar fixed aspect ratio. However, differential EC response amplitude is dependent on the area of the crack face, not the length or depth. Additionally, due to complex stresses, in-service cracks do not always grow in the assumed manner. It would be advantageous to use more of the information contained in the EC data to better determine the full profile of cracks independent of the fixed aspect ratio amplitude response curve. A specimen with narrow width notches is used to mimic cracks of varying aspect ratios in a controllable manner. The specimen notches have aspect ratios that vary from 1:1 to 10:1. Analysis routines have been developed using the shape of the EC response signals that can determine the length of a surface flaw of common orientations without use of the amplitude of the signal or any supporting traditional probability of detection basis. Combined with the relationship between signal amplitude and area, the depth of the flaw can also be calculated.

  19. Cryogenic Thermal Absorptance Measurements on Small-Diameter Stainless Steel Tubing

    Science.gov (United States)

    Tuttle, James; Jahromi, Amir; Canavan, Edgar; DiPirro, Michael

    2015-01-01

    The Mid Infrared Instrument (MIRI) on the James Webb Space Telescope includes a mechanical cryocooler which cools its detectors to their 6 Kelvin operating temperature. The coolant gas flows through several meters of small-diameter stainless steel tubing, which is exposed to thermal radiation from its environment. Over much of its length this tubing is gold-plated to minimize the absorption of this radiant heat. In order to confirm that the cryocooler will meet MIRI's requirements, the thermal absorptance of this tubing was measured as a function of its environment temperature. We describe the measurement technique and present the results.

  20. Fixation strength of biocomposite wedge interference screw in ACL reconstruction: effect of screw length and tunnel/screw ratio. A controlled laboratory study

    Directory of Open Access Journals (Sweden)

    Herrera Antonio

    2010-06-01

    Full Text Available Abstract Background Primary stability of the graft is essential in anterior cruciate ligament surgery. An optimal method of fixation should be easy to insert and provide great resistance against pull-out forces. A controlled laboratory study was designed to test the primary stability of ACL tendinous grafts in the tibial tunnel. The correlation between resistance to traction forces and the cross-section and length of the screw was studied. Methods The tibial phase of ACL reconstruction was performed in forty porcine tibias using digital flexor tendons of the same animal. An 8 mm tunnel was drilled in each specimen and two looped tendons placed as graft. Specimens were divided in five groups according to the diameter and length of the screw used for fixation. Wedge interference screws were used. Longitudinal traction was applied to the graft with a Servohydraulic Fatigue System. Load and displacement were controlled and analyzed. Results The mean loads to failure for each group were 295,44 N (Group 1; 9 × 23 screw, 564,05 N (Group 2; 9 × 28, 614,95 N (Group 3; 9 × 35, 651,14 N (Group 4; 10 × 28 and 664,99 (Group 5; 10 × 35. No slippage of the graft was observed in groups 3, 4 and 5. There were significant differences in the load to failure among groups (ANOVA/P Conclusions Longer and wider interference screws provide better fixation in tibial ACL graft fixation. Short screws (23 mm do not achieve optimal fixation and should be implanted only with special requirements.

  1. Spectroscopic study of the diameter distribution of B-doped single-walled carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz-Soria, G.; Pichler, T.; Ayala, P. [University of Vienna, Faculty of Physics, 1090 Vienna (Austria); Daothong, S. [Chiang Mai University, Faculty of Science, 50200 Chiang Mai (Thailand)

    2012-12-15

    In this paper, we report on the diameter distribution of boron-doped single-walled carbon nanotubes grown from triethyl borate with high vacuum chemical vapor deposition, using multi-frequency Raman resonance spectroscopy. The nanotube yield is higher than in previously reported material produced with the same method. Our results suggest that the amount of as-grown material and the range of diameters are directly correlated with feedstock used in the synthesis. The I{sub D}/I{sub G} ratio shows that the morphology of the samples is critically affected by the temperature. The population of diameters in the optimal conditions shows a Poisson distribution with a mean value at {proportional_to}1.15 nm. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  2. Experimental Study about Two-phase Damping Ratio on a Tube Bundle Subjected to Homogeneous Two-phase Flow

    Energy Technology Data Exchange (ETDEWEB)

    Sim, Woo Gun; Dagdan, Banzragch [Hannam Univ., Daejeon (Korea, Republic of)

    2017-03-15

    Two-phase cross flow exists in many shell-and-tube heat exchangers such as condensers, evaporators, and nuclear steam generators. The drag force acting on a tube bundle subjected to air/water flow is evaluated experimentally. The cylinders subjected to two-phase flow are arranged in a normal square array. The ratio of pitch to diameter is 1.35, and the diameter of the cylinder is 18 mm. The drag force along the flow direction on the tube bundles is measured to calculate the drag coefficient and the two-phase damping ratio. The two-phase damping ratios, given by the analytical model for a homogeneous two-phase flow, are compared with experimental results. The correlation factor between the frictional pressure drop and the hydraulic drag coefficient is determined from the experimental results. The factor is used to calculate the drag force analytically. It is found that with an increase in the mass flux, the drag force, and the drag coefficients are close to the results given by the homogeneous model. The result shows that the damping ratio can be calculated using the homogeneous model for bubbly flow of sufficiently large mass flux.

  3. Design and Optimization of Tube Type Interior Permanent Magnets Generator for Free Piston Applications

    Directory of Open Access Journals (Sweden)

    Serdal ARSLAN

    2017-05-01

    Full Text Available In this study a design and optimization of a generator to be used in free piston applications was made. In order to supply required initial force, an IPM (interior permanent magnets cavity tube type linear generator was selected. By using analytical equations’ basic dimensioning of generator was made. By using Ansys-Maxwell dimensioning, analysis and optimization of the generator was realized. Also, the effects of design basic variables (pole step ratio, cavity step ratio, inner diameter - outer diameter ratio, primary final length, air interval on pinking force were examined by using parametric analyses. Among these variables, cavity step ratio, inner diameter - outer diameter ratio, primary final length were optimally determined by algorithm and sequential nonlinear programming. The two methods were compared in terms of pinking force calculation problem. Preliminary application of the linear generator was performed for free piston application.

  4. Large eddy simulation of turbulent flow for wall mounted cantilever cylinders of aspect ratio 6 and 10

    International Nuclear Information System (INIS)

    Afgan, Imran; Moulinec, Charles; Prosser, Robert; Laurence, Dominique

    2007-01-01

    The flow structure around wall mounted circular cylinders of finite heights is numerically investigated via large eddy simulation (LES). The cylinder aspect ratios (AR) are 6 and 10 and the Reynolds number (Re) based on cylinder diameter and free stream velocity is 20,000 for both cases. The cantilever cylinder mounted on a flat plate is chosen since it gives insight into two entirely different flow phenomena; the tip effects of the free end (which show strong three-dimensional wake structures) and the base or junction effects (due to interaction of flow between the cylinder and the flat plate). Regular vortex shedding is found in the wake of the higher aspect ratio case as was anticipated, along with a strong downwash originating from the flow over the free end of the cylinder, whereas irregular and intermittent vortex shedding occurs in the lower aspect ratio case. Pressure distributions are computed along the length of the cylinder and compared to experimental results. Lift and drag values are also computed, along with Strouhal numbers

  5. FTO associations with obesity and telomere length.

    Science.gov (United States)

    Zhou, Yuling; Hambly, Brett D; McLachlan, Craig S

    2017-09-01

    This review examines the biology of the Fat mass- and obesity-associated gene (FTO), and the implications of genetic association of FTO SNPs with obesity and genetic aging. Notably, we focus on the role of FTO in the regulation of methylation status as possible regulators of weight gain and genetic aging. We present a theoretical review of the FTO gene with a particular emphasis on associations with UCP2, AMPK, RBL2, IRX3, CUX1, mTORC1 and hormones involved in hunger regulation. These associations are important for dietary behavior regulation and cellular nutrient sensing via amino acids. We suggest that these pathways may also influence telomere regulation. Telomere length (TL) attrition may be influenced by obesity-related inflammation and oxidative stress, and FTO gene-involved pathways. There is additional emerging evidence to suggest that telomere length and obesity are bi-directionally associated. However, the role of obesity risk-related genotypes and associations with TL are not well understood. The FTO gene may influence pathways implicated in regulation of TL, which could help to explain some of the non-consistent relationship between weight phenotype and telomere length that is observed in population studies investigating obesity.

  6. On the electron to proton mass ratio and the proton structure

    DEFF Research Database (Denmark)

    Trinhammer, Ole L.

    2013-01-01

    We derive an expression for the electron to nucleon mass ratio from a reinterpreted lattice gauge theory Hamiltonian to describe interior baryon dynamics. We use the classical electron radius as our fundamental length scale. Based on expansions on trigonometric Slater determinants for a neutral s...... and d valence quarks of the proton....

  7. Effect of Alkaline Activator to Fly Ash Ratio for Geopolymer Stabilized Soil

    Directory of Open Access Journals (Sweden)

    Abdullah Muhammad Sofian

    2017-01-01

    Full Text Available Geopolymer technology have been developed and explored especially in the construction material field. However, lack of research related to geopolymer stabilized soil. In this research, the utilization of geopolymer has been investigated to stabilize the soil including the factors that affecting the geopolymerization process. Unconfined compressive test (UCT used as indicator to the strength development and hence evaluating the performance of geopolymer stabilized soil. This paper focusing on the effect of fly ash/alkaline activator ratio, Na2SiO3/NaOH ratio and curing time on geopolymer stabilized soil. A various mix design at different fly ash/alkaline activator ratio, Na2SiO3/NaOH ratio were prepared and cured for 7 and 28 days. Molarity and the percentage of geopolymer to soil were fixed at 10 molar and 8 percent respectively. Then, the UCT tests were carried out on 38mm diameter x 76mm height specimens. The highest strength obtained at the fly ash/alkaline activator ratio 2.5 and Na2SiO3/NaOH ratio 2.0 at 28 days curing time.

  8. The effects of alcohol to oil molar ratios and the type of alcohol on biodiesel production using transesterification process

    Directory of Open Access Journals (Sweden)

    Idris Atadashi Musa

    2016-03-01

    Full Text Available The nature of alcohol and alcohol to oil molar ratio plays an important role on the method of biodiesel production. As a result, this paper examined different alcohols commonly used for the production of biodiesel fuel with more emphasis on methanol and ethanol. Further the different alcohol to oil molar ratios used for the production of biodiesel have been extensively discussed and reported. Also the effects of alcohol to molar ratios on biodiesel refining process and its physicochemical properties were investigated.

  9. Ratio of critical quantities related to Hawking temperature–entanglement entropy criticality

    Directory of Open Access Journals (Sweden)

    Jie-Xiong Mo

    2017-10-01

    Full Text Available We revisit the Hawking temperature–entanglement entropy criticality of the d-dimensional charged AdS black hole with our attention concentrated on the ratio TcδSEcQc. Comparing the results of this paper with those of the ratio TcScQc, one can find both the similarities and differences. These two ratios are independent of the characteristic length scale l and dependent on the dimension d. These similarities further enhance the relation between the entanglement entropy and the Bekenstein–Hawking entropy. However, the ratio TcδSEcQc also relies on the size of the spherical entangling region. Moreover, these two ratios take different values even under the same choices of parameters. The differences between these two ratios can be attributed to the peculiar property of the entanglement entropy since the research in this paper is far from the regime where the behavior of the entanglement entropy is dominated by the thermal entropy.

  10. Prenatal ultrasonographic findings of multicystic dysplastic kidney: Emphasis on cyst distribution

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Min Hoan; Cho, Jeong Yeon [Samsung Cheil Hospital, Sungkunkwan University school of Medicine, Seoul (Korea, Republic of)

    2003-09-15

    To characterize the ultrasonographic findings of multicystic dysplastic kidney on prenatal ultrasonography (US) with a special emphasis on the distribution of cysts. From January 1998 to March 2003, medical records of sixty two subjects with multicystic dysplastic kidney diagnosed on prenatal US examination were retrospectively reviewed, and forty three patients confirmed either by pathology or postnatal follow-up US were selected for this study. US assessment included the time of diagnosis, laterality, size of the multicystic dysplastic and contralateral normal kidneys, distribution of cysts and associated anomalies. The distribution of cysts was categorized as subcapsular and random distribution, and interobserver agreement was determined using the cross table analysis. The largest multicystic and contralateral normal longitudinal diameters were measured, and the data were plotted on the normal reference chart. Multicystic dysplastic kidney was left sided in 55.8%, right sided in 34.8% and bilateral in 9.3%. Subcapsular distribution of cysts was observed in 68.2% (n=15) for radiologist 1 while 59.1% (n=13) for radiologist 2, showing an excellent interobserver agreement (k=0.697). The longitudinal diameter of the multicystic dysplastic kidney was above 95 percentile in 68%. Meanwhile, the diameter of the contralateral normal kidney was more commonly normal, 70%. Fetal karyotyping was done in 18 cases including 2 cases with associated major anomalies, but karyotyping was all normal. On prenatal US, subcapsular distribution of cysts in multicystic dysplastic kidney is more common than random distribution. This characteristic distribution of cysts may be helpful in the prenatal diagnosis of multicystic dysplastic kidney.

  11. Prenatal ultrasonographic findings of multicystic dysplastic kidney: Emphasis on cyst distribution

    International Nuclear Information System (INIS)

    Moon, Min Hoan; Cho, Jeong Yeon

    2003-01-01

    To characterize the ultrasonographic findings of multicystic dysplastic kidney on prenatal ultrasonography (US) with a special emphasis on the distribution of cysts. From January 1998 to March 2003, medical records of sixty two subjects with multicystic dysplastic kidney diagnosed on prenatal US examination were retrospectively reviewed, and forty three patients confirmed either by pathology or postnatal follow-up US were selected for this study. US assessment included the time of diagnosis, laterality, size of the multicystic dysplastic and contralateral normal kidneys, distribution of cysts and associated anomalies. The distribution of cysts was categorized as subcapsular and random distribution, and interobserver agreement was determined using the cross table analysis. The largest multicystic and contralateral normal longitudinal diameters were measured, and the data were plotted on the normal reference chart. Multicystic dysplastic kidney was left sided in 55.8%, right sided in 34.8% and bilateral in 9.3%. Subcapsular distribution of cysts was observed in 68.2% (n=15) for radiologist 1 while 59.1% (n=13) for radiologist 2, showing an excellent interobserver agreement (k=0.697). The longitudinal diameter of the multicystic dysplastic kidney was above 95 percentile in 68%. Meanwhile, the diameter of the contralateral normal kidney was more commonly normal, 70%. Fetal karyotyping was done in 18 cases including 2 cases with associated major anomalies, but karyotyping was all normal. On prenatal US, subcapsular distribution of cysts in multicystic dysplastic kidney is more common than random distribution. This characteristic distribution of cysts may be helpful in the prenatal diagnosis of multicystic dysplastic kidney.

  12. Imaging of 1.0-mm-diameter radiopaque markers with megavoltage X-rays: an improved online imaging system

    International Nuclear Information System (INIS)

    Pang, G.; Beachey, D.J.; O'Brien, P.F.; Rowlands, J.A.

    2002-01-01

    Purpose: To improve an online portal imaging system such that implanted cylindrical gold markers of small diameter (no more than 1.0 mm) can be visualized. These small markers would make the implantation procedure much less traumatic for the patient than the large markers (1.6 mm in diameter), which are usually used today to monitor prostate interfraction motion during radiation therapy. Methods and Materials: Several changes have been made to a mirror-video based online imaging system to improve image quality. First, the conventional camera tube was replaced by an avalanche-multiplication-based video tube. This new camera tube has very high gain at the target such that the camera noise, which is one of the main causes of image degradation of online portal imaging systems, was overcome and effectively eliminated. Second, the conventional linear-accelerator (linac) target was replaced with a low atomic number (low-Z) target such that more diagnostic X-rays are present in the megavoltage X-ray beam. Third, the copper plate buildup layer for the phosphor screen was replaced by a thin plastic layer for detection of the diagnostic X-ray components in the beam generated by the low-Z target. Results: Radiopaque fiducial gold markers of different sizes, i.e., 1.0 mm (diameter) x 5 mm (length) and 0.8 mm (diameter) x 3 mm (length), embedded in an Alderson Rando phantom, can be clearly seen on the images acquired with our improved system. These markers could not be seen on images obtained with any commercial system available in our clinic. Conclusion: This work demonstrates the visibility of small-diameter radiopaque markers with an improved online portal imaging system. These markers can be easily implanted into the prostate and used to monitor the interfraction motion of the prostate

  13. Maternal and ambient environmental effects of light on germination in Plantago lanceolata: correlated responses to selection on leaf length

    International Nuclear Information System (INIS)

    Hinsberg, A. van

    1998-01-01

    1. Seeds from artificial selection lines were exposed to different maternal and ambient conditions, simulating sunlight and vegetation shade. 2. Lines selected for longer leaves also produced larger seeds, indicating a positive genetic correlation between leaf length and seed size. 3. Light conditions during maturation had no large effect on seed size. 4. Seed germination was reduced by a low ratio of red to far-red light (R/FR ratio) in the ambient environment. 5. Seeds maturated under simulated vegetation shade germinated less readily and were more inhibited by a low ambient R/FR ratio than seeds maturated under full sunlight or R/FR-neutral shade. Thus, low R/FR-ratios in the maternal and ambient environment operated synergistically. 6. Large genotypic variation in the germination responses to both maternal and ambient light conditions was found among and within selection lines, indicating that such responses might have the potential to evolve in response to natural selection. 7. Artificial selection for leaf length had affected seed germination characteristics but correlated responses and thus genetic correlations largely depended on light conditions in the selective environment. Selection for longer leaves under a low R/FR ratio increased seed dormancy and plasticity of germination in response to the R/FR ratio. However, in the opposite selective environment selection for longer leaves reduced seed dormancy and plasticity to the R/FR ratio. It is argued that leaf length and seed germination characteristics are somehow linked by shared physiological mechanisms, which may facilitate concerted changes in shade avoidance responses

  14. High aspect ratio piezoelectric strontium-bismuth-tantalate nanotubes

    International Nuclear Information System (INIS)

    Morrison, Finlay D; Ramsay, Laura; Scott, James F

    2003-01-01

    We report the deposition and characterization of transparent ferroelectric/piezoelectric nanotubes of wall thickness about 40 nm, tube diameters ranging from a few hundred nanometres to 4 μm, and length about 100 μm. Comparison with other nanotubes is made and applications in dynamic random access memory trenching and ink-jet printers are discussed. (letter to the editor)

  15. Formation of high aspect ratio polyamide-6 nanofibers via electrically induced double layer during electrospinning

    International Nuclear Information System (INIS)

    Nirmala, R.; Nam, Ki Taek; Park, Soo-Jin; Shin, Yu-Shik; Navamathavan, R.; Kim, Hak Yong

    2010-01-01

    In the present study, the formation of high aspect ratio nanofibers in polyamide-6 was investigated as a function of applied voltage ranging from 15 to 25 kV using electrospinning technique. All other experimental parameters were kept constant. The electrospun polyamide-6 nanofibers were characterized by field-emission scanning electron microscopy (FE-SEM), transmission electron microscopy (TEM) and matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF). FE-SEM images of polyamide-6 nanofibers showed that the diameter of the electrospun fiber was decreased with increasing applied voltage. At the critical applied voltage, the polymer solution was completely ionized to form the dense high aspect ratio nanofibers in between the main nanofibers. The diameter of the polyamide-6 nanofibers was observed to be in the range of 75-110 nm, whereas the high aspect ratio structures consisted of regularly distributed very fine nanofibers with diameters of about 9-28 nm. Trends in fiber diameter and diameter distribution were discussed for the high aspect ratio nanofibers. TEM results revealed that the formation of double layers in polyamide-6 nanofibers and then split-up into ultrafine fibers. The electrically induced double layer in combination with the polyelectrolytic nature of solution is proposed as the suitable mechanisms for the formation of high aspect ratio nanofibers in polyamide-6.

  16. The control of beads diameter of bead-on-string electrospun nanofibers and the corresponding release behaviors of embedded drugs

    Energy Technology Data Exchange (ETDEWEB)

    Li, Tingxiao [Key Laboratory of Textile Science and Technology (Donghua University), Ministry of Education of China, Shanghai 201620 (China); College of Textiles, Donghua University, Shanghai 201620 (China); Ding, Xin, E-mail: xding@dhu.edu.cn [Key Laboratory of Textile Science and Technology (Donghua University), Ministry of Education of China, Shanghai 201620 (China); College of Textiles, Donghua University, Shanghai 201620 (China); Tian, Lingling, E-mail: lingling_tian@nus.edu.sg [Center of Nanofibers & Nanotechnology, Department of Mechanical Engineering, National University of Singapore, 117576 (Singapore); Hu, Jiyong; Yang, Xudong [Key Laboratory of Textile Science and Technology (Donghua University), Ministry of Education of China, Shanghai 201620 (China); College of Textiles, Donghua University, Shanghai 201620 (China); Ramakrishna, Seeram [Center of Nanofibers & Nanotechnology, Department of Mechanical Engineering, National University of Singapore, 117576 (Singapore); Guangdong-Hongkong-Macau Institute of CNS Regeneration (GHMICR), Jinan University, Guangzhou 510632 (China)

    2017-05-01

    Bead-on-string nanofibers, with appropriate control of the beads diameter, are potential fibrous structures for efficient encapsulation of particle drugs in micron scales and could achieve controlled drug release for tissue engineering applications. In this study, the beads diameter of electrospun bead-on-string nanofibers was controlled by adjusting the concentration of spinning polymer, poly (lactic-co-glycolic acid) (PLGA), and the solvent ratio of chloroform to acetone. The images of the scanning electron microscopy (SEM) suggested that bead-on-string nanofibers could be successfully obtained only with a certain range of PLGA solution concentration. Moreover, with the decrease in the solvent ratio of chloroform to acetone, the range was left-shifted towards a smaller concentration. In addition, increase in the PLGA solution concentration within the range the beads diameter became greater and the shape of the beads changed from oval to slender when increasing the PLGA concentration within the range. The bead-on-string nanofibers with different beads diameter were further used to load micro-particle drugs of tetracycline hydrochloride, as a model drug, to examine the release behavior of nanofibers scaffold. The release profiles of drug loaded bead-on-string nanofibers demonstrated the possibility to alleviate the burst drug release by means of beads diameter control. - Highlights: • Bead diameter of bead-on-string electrospun nanofibers was controlled by varying solvent ratio and polymer concentration. • The effect of the addition of particle drugs on BD of bead-on-string electrospun nanofibers was studied. • The corresponding release behaviors of nanofibers with different BD loading micro-particle drugs were investigated. • Bead-on-string nanofibers with bigger BD could alleviate the initial burst release.

  17. The control of beads diameter of bead-on-string electrospun nanofibers and the corresponding release behaviors of embedded drugs

    International Nuclear Information System (INIS)

    Li, Tingxiao; Ding, Xin; Tian, Lingling; Hu, Jiyong; Yang, Xudong; Ramakrishna, Seeram

    2017-01-01

    Bead-on-string nanofibers, with appropriate control of the beads diameter, are potential fibrous structures for efficient encapsulation of particle drugs in micron scales and could achieve controlled drug release for tissue engineering applications. In this study, the beads diameter of electrospun bead-on-string nanofibers was controlled by adjusting the concentration of spinning polymer, poly (lactic-co-glycolic acid) (PLGA), and the solvent ratio of chloroform to acetone. The images of the scanning electron microscopy (SEM) suggested that bead-on-string nanofibers could be successfully obtained only with a certain range of PLGA solution concentration. Moreover, with the decrease in the solvent ratio of chloroform to acetone, the range was left-shifted towards a smaller concentration. In addition, increase in the PLGA solution concentration within the range the beads diameter became greater and the shape of the beads changed from oval to slender when increasing the PLGA concentration within the range. The bead-on-string nanofibers with different beads diameter were further used to load micro-particle drugs of tetracycline hydrochloride, as a model drug, to examine the release behavior of nanofibers scaffold. The release profiles of drug loaded bead-on-string nanofibers demonstrated the possibility to alleviate the burst drug release by means of beads diameter control. - Highlights: • Bead diameter of bead-on-string electrospun nanofibers was controlled by varying solvent ratio and polymer concentration. • The effect of the addition of particle drugs on BD of bead-on-string electrospun nanofibers was studied. • The corresponding release behaviors of nanofibers with different BD loading micro-particle drugs were investigated. • Bead-on-string nanofibers with bigger BD could alleviate the initial burst release.

  18. Sonographic cervical length, vaginal bleeding, and the risk of preterm birth.

    Science.gov (United States)

    Ramaeker, Devon M; Simhan, Hyagriv N

    2012-03-01

    We sought to evaluate the contributions of vaginal bleeding and cervical length to the risk of preterm birth. This was a secondary analysis of a cohort study designed to study predictors of preterm birth. The study included 2988 women with singleton gestations. Women underwent midtrimester transvaginal ultrasound assessment of cervical length and were queried regarding first- and second-trimester vaginal bleeding. There was a significant second-order relation between cervical length and preterm birth (P birth (odds ratio, 1.5; 95% confidence interval, 1.3-2.0). There was a significant interaction between cervical length and vaginal bleeding (P = .015). After accounting for cervical length and interaction, the adjusted odds ratio for vaginal bleeding and preterm birth was 4.8 (95% confidence interval, 1.89-12.4; P = .001). The magnitude of risk of preterm birth associated with sonographic cervical length depends on a woman's history of first- and second-trimester vaginal bleeding. Copyright © 2012 Mosby, Inc. All rights reserved.

  19. Primary Dendrite Arm Spacing and Trunk Diameter in Al-7-Weight-Percentage Si Alloy Directionally Solidified Aboard the International Space Station

    Science.gov (United States)

    Ghods, M.; Tewari, S. N.; Lauer, M.; Poirier, D. R.; Grugel, R. N.

    2016-01-01

    Under a NASA-ESA collaborative research project, three Al-7-weight-percentage Si samples (MICAST-6, MICAST-7 and MICAST 2-12) were directionally solidified aboard the International Space Station to determine the effect of mitigating convection on the primary dendrite array. The samples were approximately 25 centimeters in length with a diameter of 7.8 millimeter-diameter cylinders that were machined from [100] oriented terrestrially grown dendritic Al-7Si samples and inserted into alumina ampoules within the Sample Cartridge Assembly (SCA) inserts of the Low Gradient Furnace (LGF). The feed rods were partially remelted in space and directionally solidified to effect the [100] dendrite-orientation. MICAST-6 was grown at 5 microns per second for 3.75 centimeters and then at 50 microns per second for its remaining 11.2 centimeters of its length. MICAST-7 was grown at 20 microns per second for 8.5 centimeters and then at 10 microns per second for 9 centimeters of its remaining length. MICAST2-12 was grown at 40 microns per second for 11 centimeters. The thermal gradient at the liquidus temperature varied from 22 to 14 degrees Kelvin per centimeter during growth of MICAST-6, from 26 to 24 degrees Kelvin per centimeter for MICAST-7 and from 33 to 31 degrees Kelvin per centimeter for MICAST2-12. Microstructures on the transverse sections along the sample length were analyzed to determine nearest-neighbor spacing of the primary dendrite arms and trunk diameters of the primary dendrite-arrays. This was done along the lengths where steady-state growth prevailed and also during the transients associated with the speed-changes. The observed nearest-neighbor spacings during steady-state growth of the MICAST samples show a very good agreement with predictions from the Hunt-Lu primary spacing model for diffusion controlled growth. The observed primary dendrite trunk diameters during steady-state growth of these samples also agree with predictions from a coarsening-based model

  20. Fractionation and Characterization of High Aspect Ratio Gold Nanorods Using Asymmetric-Flow Field Flow Fractionation and Single Particle Inductively Coupled Plasma Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Thao M. Nguyen

    2015-07-01

    Full Text Available Gold nanorods (GNRs are of particular interest for biomedical applications due to their unique size-dependent longitudinal surface plasmon resonance band in the visible to near-infrared. Purified GNRs are essential for the advancement of technologies based on these materials. Used in concert, asymmetric-flow field flow fractionation (A4F and single particle inductively coupled mass spectrometry (spICP-MS provide unique advantages for fractionating and analyzing the typically complex mixtures produced by common synthetic procedures. A4F fractions collected at specific elution times were analyzed off-line by spICP-MS. The individual particle masses were obtained by conversion of the ICP-MS pulse intensity for each detected particle event, using a defined calibration procedure. Size distributions were then derived by transforming particle mass to length assuming a fixed diameter. The resulting particle lengths correlated closely with ex situ transmission electron microscopy. In contrast to our previously reported observations on the fractionation of low-aspect ratio (AR GNRs (AR < 4, under optimal A4F separation conditions the results for high-AR GNRs of fixed diameter (≈20 nm suggest normal, rather than steric, mode elution (i.e., shorter rods with lower AR generally elute first. The relatively narrow populations in late eluting fractions suggest the method can be used to collect and analyze specific length fractions; it is feasible that A4F could be appropriately modified for industrial scale purification of GNRs.

  1. Relationship Between Seed Yield And Some of Fruit Traits in Iranian Squash (Cucurbita pepo L. Accissions

    Directory of Open Access Journals (Sweden)

    R. Barzegar

    2016-02-01

    Full Text Available In order to evaluation of squash (Cucurbita pepo seed yield per fruit and its relations with other characteristics of fruit include: length, diameter, length: diameter ratio (fruit shape, flesh thickness, thousand seed weight and fruit weight, an experiment was conducted using 24 accessions of squash as a randomized complete-block design with three replications. Morphological traits were evaluated according to UPOV descriptor and UPGMA clustering algorithm clustered the accessions in 4 groups (predominantly on the basis of fruit shape. Correlation, regression and path analysis were done for mentioned characteristics in 4 type-fruit groups. There was negative correlation between seed yield of individual fruit and its length and fruit length: diameter ratio. But fruit weight, fruit diameter, and thousand seeds weight had positive correlation with seed yield. Seed weight: fruit weight ratio had negative relationship with fruit weight. Therefore small size fruit is more suitable for seed yield per area. Path analysis was showed fruit weight had the most positive direct effect on seed yield per fruit in all groups.

  2. A study of unsteady physiological magneto-fluid flow and heat transfer through a finite length channel by peristaltic pumping.

    Science.gov (United States)

    Tripathi, Dharmendra; Bég, O Anwar

    2012-08-01

    Magnetohydrodynamic peristaltic flows arise in controlled magnetic drug targeting, hybrid haemodynamic pumps and biomagnetic phenomena interacting with the human digestive system. Motivated by the objective of improving an understanding of the complex fluid dynamics in such flows, we consider in the present article the transient magneto-fluid flow and heat transfer through a finite length channel by peristaltic pumping. Reynolds number is small enough and the wavelength to diameter ratio is large enough to negate inertial effects. Analytical solutions for temperature field, axial velocity, transverse velocity, pressure gradient, local wall shear stress, volume flowrate and averaged volume flowrate are obtained. The effects of the transverse magnetic field, Grashof number and thermal conductivity on the flow patterns induced by peristaltic waves (sinusoidal propagation along the length of channel) are studied using graphical plots. The present study identifies that greater pressure is required to propel the magneto-fluid by peristaltic pumping in comparison to a non-conducting Newtonian fluid, whereas, a lower pressure is required if heat transfer is effective. The analytical solutions further provide an important benchmark for future numerical simulations.

  3. Measuring digit lengths with 3D digital stereophotogrammetry: A comparison across methods.

    Science.gov (United States)

    Gremba, Allison; Weinberg, Seth M

    2018-05-09

    We compared digital 3D stereophotogrammetry to more traditional measurement methods (direct anthropometry and 2D scanning) to capture digit lengths and ratios. The length of the second and fourth digits was measured by each method and the second-to-fourth ratio was calculated. For each digit measurement, intraobserver agreement was calculated for each of the three collection methods. Further, measurements from the three methods were compared directly to one another. Agreement statistics included the intraclass correlation coefficient (ICC) and technical error of measurement (TEM). Intraobserver agreement statistics for the digit length measurements were high for all three methods; ICC values exceeded 0.97 and TEM values were below 1 mm. For digit ratio, intraobserver agreement was also acceptable for all methods, with direct anthropometry exhibiting lower agreement (ICC = 0.87) compared to indirect methods. For the comparison across methods, the overall agreement was high for digit length measurements (ICC values ranging from 0.93 to 0.98; TEM values below 2 mm). For digit ratios, high agreement was observed between the two indirect methods (ICC = 0.93), whereas indirect methods showed lower agreement when compared to direct anthropometry (ICC < 0.75). Digit measurements and derived ratios from 3D stereophotogrammetry showed high intraobserver agreement (similar to more traditional methods) suggesting that landmarks could be placed reliably on 3D hand surface images. While digit length measurements were found to be comparable across all three methods, ratios derived from direct anthropometry tended to be higher than those calculated indirectly from 2D or 3D images. © 2018 Wiley Periodicals, Inc.

  4. An experimental investigation on the pressure characteristics of high speed self-resonating pulsed waterjets influenced by feeding pipe diameter

    Energy Technology Data Exchange (ETDEWEB)

    Li, Dong; Kang, Dong; Ding, Xiao Long; Wang, Xiao Huan; Fang, Zhen Long [School of Power and Mechanical Engineering, Wuhan University, Hubei Province (China)

    2016-11-15

    The destructive power of a continuous waterjet issuing from a nozzle can be greatly enhanced by generating self-resonance in the nozzle assembly to produce a Self-resonating pulsed waterjet (SRPW). To further improve the performance of SRPW, effects of feeding pipe diameter on the pressure characteristics were experimentally investigated by measuring and analyzing the axial pressure oscillation peaks and amplitudes. Four organ-pipe nozzles of different chamber lengths and three feeding pipes of different diameters were employed. Results show that feeding pipe diameter cannot change the feature of SRPW of having an optimum standoff distance, but it slightly changes the oscillating frequency of the jet. It is also found that feeding pipe diameter significantly affects the magnitudes of pressure oscillation peak and amplitude, largely depending on the pump pressure and standoff distance. The enhancement or attenuation of the pressure oscillation peak and amplitude can be differently affected by the same feeding pipe diameter.

  5. Reduction of nanowire diameter beyond lithography limits by controlled catalyst dewetting

    Science.gov (United States)

    Calahorra, Yonatan; Kerlich, Alexander; Amram, Dor; Gavrilov, Arkady; Cohen, Shimon; Ritter, Dan

    2016-04-01

    Catalyst assisted vapour-liquid-solid is the most common method to realize bottom-up nanowire growth; establishing a parallel process for obtaining nanoscale catalysts at pre-defined locations is paramount for further advancement towards commercial nanowire applications. Herein, the effect of a selective area mask on the dewetting of metallic nanowire catalysts, deposited within lithography-defined mask pinholes, is reported. It was found that thin disc-like catalysts, with diameters of 120-450 nm, were transformed through dewetting into hemisphere-like catalysts, having diameters 2-3 fold smaller; the process was optimized to about 95% yield in preventing catalyst splitting, as would otherwise be expected due to their thickness-to-diameter ratio, which was as low as 1/60. The catalysts subsequently facilitated InP and InAs nanowire growth. We suggest that the mask edges prevent surface migration mediated spreading of the dewetted metal, and therefore induce its agglomeration into a single particle. This result presents a general strategy to diminish lithography-set dimensions for NW growth, and may answer a fundamental challenge faced by bottom-up nanowire technology.

  6. Poisson's ratio of collagen fibrils measured by small angle X-ray scattering of strained bovine pericardium

    Energy Technology Data Exchange (ETDEWEB)

    Wells, Hannah C.; Sizeland, Katie H.; Kayed, Hanan R.; Haverkamp, Richard G., E-mail: r.haverkamp@massey.ac.nz [School of Engineering and Advanced Technology, Massey University, Private Bag 11222, Palmerston North 4442 (New Zealand); Kirby, Nigel; Hawley, Adrian; Mudie, Stephen T. [Australian Synchrotron, 800 Blackburn Road, Clayton, Victoria 3168 (Australia)

    2015-01-28

    Type I collagen is the main structural component of skin, tendons, and skin products, such as leather. Understanding the mechanical performance of collagen fibrils is important for understanding the mechanical performance of the tissues that they make up, while the mechanical properties of bulk tissue are well characterized, less is known about the mechanical behavior of individual collagen fibrils. In this study, bovine pericardium is subjected to strain while small angle X-ray scattering (SAXS) patterns are recorded using synchrotron radiation. The change in d-spacing, which is a measure of fibril extension, and the change in fibril diameter are determined from SAXS. The tissue is strained 0.25 (25%) with a corresponding strain in the collagen fibrils of 0.045 observed. The ratio of collagen fibril width contraction to length extension, or the Poisson's ratio, is 2.1 ± 0.7 for a tissue strain from 0 to 0.25. This Poisson's ratio indicates that the volume of individual collagen fibrils decreases with increasing strain, which is quite unlike most engineering materials. This high Poisson's ratio of individual fibrils may contribute to high Poisson's ratio observed for tissues, contributing to some of the remarkable properties of collagen-based materials.

  7. Diameter-speed relation of sprite streamers

    International Nuclear Information System (INIS)

    Kanmae, T; Stenbaek-Nielsen, H C; McHarg, M G; Haaland, R K

    2012-01-01

    Propagation and splitting of sprite streamers has been observed at high temporal and spatial resolution using two intensified high-speed CMOS cameras recording at 10 000 and 16 000 frames per second. Concurrent video recordings from a remote site provided data for triangulation allowing us to determine accurate altitude scales for the sprites. Diameters and speeds of the sprite streamers were measured from the high-speed images, and the diameters were scaled to the reduced diameters based on the triangulated locations. The sprite streamers with larger reduced diameter move faster than those with smaller diameter; the relation between the reduced diameter and speed is roughly linear. The reduced diameters at ≈65-70 km altitude are larger than streamer diameters measured at ground pressure in laboratory discharges indicating a deviation from the similarity law possibly due to the effects of the photoionization and an expansion of the streamer head along its propagation over a long distance. The reduced diameter and speed of the sprite streamers agree well with the diameter-velocity relation proposed by Naidis (2009 Phys. Rev. E 79 057401), and the peak electric field of the sprite streamers is estimated to be approximately 3-5 times the breakdown threshold field. (paper)

  8. Position of the Patella among Emirati Adult Knees. Is Insall-Salvati Ratio Applicable to Middle-Easterners?

    Directory of Open Access Journals (Sweden)

    Saeed Althani

    2016-04-01

    Full Text Available Background: Abnormal patellar height is associated with anterior knee pain and several conditions that affect the patellofemoral joint. The aim of this study was to 1 report the incidence of patella alta and patella baja and 2 investigate whether the normal limits of the Insall-Salvati ratio is applicable in adult Middle-Easterners. Methods: A radiographic review of the lateral radiographs of 736 Middle-Eastern knees were performed. Patellar tendon length (TL and the patellar length (TP was digitally measured and the ratios of these measures was used to calculate the Insall-Salvati ratio. Results: The overall mean TL/PL ratio was 1.20±0.17. The Insall-Salvati ratio was higher (p=0.0013 in males (1.22± 0.12 than in females (1.18±0.17. According to our measurement, the recommended levels for defining abnormal patellar position should be 0.86 for patella baja and 1.54 for patella alta. Conclusion: The use of TL/PL ratio demonstrated a higher incidence of patella alta and a higher mean TL/PL ratio compared to other techniques. The normal ranges for the TL/PL differs from western populations and may be attributed to lifestyle differences.

  9. Mechanisms involved in the hydrothermal growth of ultra-thin and high aspect ratio ZnO nanowires

    Energy Technology Data Exchange (ETDEWEB)

    Demes, Thomas [Univ. Grenoble Alpes, CNRS, Grenoble-INP, LMGP, F-38000 Grenoble (France); Ternon, Céline, E-mail: celine.ternon@grenoble-inp.fr [Univ. Grenoble Alpes, CNRS, Grenoble-INP, LMGP, F-38000 Grenoble (France); Univ. Grenoble Alpes, CNRS, LTM, F-38000 Grenoble (France); Morisot, Fanny [Univ. Grenoble Alpes, CNRS, Grenoble-INP, LMGP, F-38000 Grenoble (France); Univ. Grenoble Alpes, CNRS, Grenoble-INP" 2, IMEP-LaHC, F-38000 Grenoble (France); Riassetto, David [Univ. Grenoble Alpes, CNRS, Grenoble-INP, LMGP, F-38000 Grenoble (France); Legallais, Maxime [Univ. Grenoble Alpes, CNRS, Grenoble-INP, LMGP, F-38000 Grenoble (France); Univ. Grenoble Alpes, CNRS, Grenoble-INP" 2, IMEP-LaHC, F-38000 Grenoble (France); Roussel, Hervé; Langlet, Michel [Univ. Grenoble Alpes, CNRS, Grenoble-INP, LMGP, F-38000 Grenoble (France)

    2017-07-15

    Highlights: • ZnO nanowires are grown on sol-gel ZnO seed layers by hydrothermal synthesis. • Ultra-thin and high aspect ratio nanowires are obtained without using additives. • Nanowire diameter is 20–25 nm regardless of growth time and seed morphology. • A nanowire growth model is developed on the basis of thermodynamic considerations. • The nanowires are intended for integration into electrically conductive nanonets. - Abstract: Hydrothermal synthesis of ZnO nanowires (NWs) with tailored dimensions, notably high aspect ratios (AR) and small diameters, is a major concern for a wide range of applications and still represents a challenging and recurring issue. In this work, an additive-free and reproducible hydrothermal procedure has been developed to grow ultra-thin and high AR ZnO NWs on sol-gel deposited ZnO seed layers. Controlling the substrate temperature and using a low reagent concentration (1 mM) has been found to be essential for obtaining such NWs. We show that the NW diameter remains constant at about 20–25 nm with growth time contrary to the NW length that can be selectively increased leading to NWs with ARs up to 400. On the basis of investigated experimental conditions along with thermodynamic and kinetic considerations, a ZnO NW growth mechanism has been developed which involves the formation and growth of nuclei followed by NW growth when the nuclei reach a critical size of about 20–25 nm. The low reagent concentration inhibits NW lateral growth leading to ultra-thin and high AR NWs. These NWs have been assembled into electrically conductive ZnO nanowire networks, which opens attractive perspectives toward the development of highly sensitive low-cost gas- or bio-sensors.

  10. The Variations of Torg Ratio with Gender in Patients with Neck Pain

    Directory of Open Access Journals (Sweden)

    Özlen Karabulut

    2007-01-01

    Full Text Available The Torg Ratio which may help to identify patients at risk for cervical spine cord injuries is an indicator of cervical canal stenosis determined by dividing the sagittal spinal canal diameter by the corresponding sagittal vertebral-body diameter. It was reported that male and female subjects showed differences in previous studies. The aim of this study was to investigate these differences. Our study that included the subjects 45 women and 45 men with neck pain was carried out at Diyarbakır State Hospital. The mean ages of male and female participants were 30 and 33. We measured both diaemeters on the lateral radiographs of the cervical spine in mm by using a Vernier Calipper. Women had smaller sagittal spinal canal and vertebral body diameters at all levels. The narrowest sagittal spinal canal diameters measured were at C4 level in men and at C2 level in women. The mean Torg Ratio was 0.73 at C4 in men and 0.80 at C2 in women. We found larger Torg Ratios in females at all cervical vertebral levels except C2 level.

  11. Growth and development of moringa (Moringa oleifera L. stem cuttings as affected by diameter magnitude, growth media, and indole-3-butyric acid

    Directory of Open Access Journals (Sweden)

    Shamsuddeen Rufai

    2016-12-01

    Full Text Available The acknowledged status of Moringa oleifera L. in sub-Saharan Africa, especially western Africa, has of recent accorded it the significance of being a good source of income to a large segment of many of its populace. Intensification of research into the realization of its full economic potential will be of utmost value to impoverished societies globally. One way to achieve this is the full exploration of all possible means that will facilitate its successful growth, propagation, and domestication. Even though it can be successfully raised through seeds, the high level outcrossing (64.3% observed is a hindrance to realization of true to type trees. Vegetative propagation can be employed as an option to tackle the noted limitation, ease the cultivation process, and achieve the required realization of its economic potential. Our trial was carried out to study the influence of two growth media and three levels of indole 3-butyric acid (IBA on root and shoot development in cuttings taken from a coppiced moringa tree existent in Universiti Putra Malaysia. Semi-hardwood cuttings of moringa, of between 20 and 30 mm diameter, cut into 25 cm length, were obtained, rinsed with a fungicide, then dipped, through their basal portion, inside varying levels (0, 1000, 2000, and 3000 ppm of indole-3-butyric acid (IBA for between 7 and 10 seconds. The treated cuttings were then transplanted into a polyethylene bags (23 cm × 36 cm, containing two growth media - a munchong series soil (M and a combination of a munchong series soil thoroughly mixed with biochar (MB in a 3:1 ratio sequence. The trial was conducted inside a shade house where the humidity of the experimental area was manipulated through a regular daily manual hand sprinkling. Plant height, percentage of primary branch produced, leaf area, and dry matter (DM were found to be significantly (P<0.05 influenced by variation in stem diameter magnitude, while the diameter of the primary branch and spad

  12. Sugar maple height-diameter and age-diameter relationships in an uneven-aged northern hardwood stand

    Science.gov (United States)

    Laura S. Kenefic; R.D. Nyland

    1999-01-01

    Sugar maple (Acer saccharum Marsh.) height-diameter and age-diameter relationships are explored in a balanced uneven-aged northern hardwood stand in central New York. Results show that although both height and age vary considerably with diameter, these relationships can be described by statistically valid equations. The age-diameter relationship...

  13. Posterior brain in fetuses with open spina bifida at 11 to 13 weeks.

    Science.gov (United States)

    Lachmann, Robert; Chaoui, Rabih; Moratalla, Jose; Picciarelli, Gemma; Nicolaides, Kypros H

    2011-01-01

    To measure the changes in the posterior fossa in first-trimester fetuses with open spina bifida (OSB). The brain stem diameter and brain stem to occipital bone (BSOB) diameter were measured in stored images of the mid-sagittal view of the fetal face at 11(+0) to 13(+6) weeks from 30 fetuses with OSB and 1000 normal controls. In the control group, the brain stem and BSOB diameter increased significantly with crown-rump length (CRL) and the brain stem to BSOB ratio decreased. In the spina bifida group, the brain stem diameter was above the 95th percentile of the control group in 29 (96.7%) cases, the BSOB diameter was below the 5th percentile in 26 (86.7%) and the brain stem to BSOB ratio was above the 95th percentile in all cases. At 11 to 13 weeks the majority of fetuses with OSB have measurable abnormalities in the posterior brain.

  14. Calculation of the Cardiothoracic Ratio from Portable Anteroposterior Chest Radiography

    Science.gov (United States)

    Chon, Sung Bin; Oh, Won Sup; Cho, Jun Hwi; Kim, Sam Soo

    2011-01-01

    Cardiothoracic ratio (CTR), the ratio of cardiac diameter (CD) to thoracic diameter (TD), is a useful screening method to detect cardiomegaly, but is reliable only on posteroanterior chest radiography (chest PA). We performed this cross-sectional 3-phase study to establish reliable CTR from anteroposterior chest radiography (chest AP). First, CDChest PA/CDChest AP ratios were determined at different radiation distances by manipulating chest computed tomography to simulate chest PA and AP. CDChest PA was inferred from multiplying CDChest AP by this ratio. Incorporating this CD and substituting the most recent TDChest PA, we calculated the 'corrected' CTR and compared it with the conventional one in patients who took both the chest radiographies. Finally, its validity was investigated among the critically ill patients who performed portable chest AP. CDChest PA/CDChest AP ratio was {0.00099 × (radiation distance [cm])} + 0.79 (n = 61, r = 1.00, P chest AP with an available previous chest PA. This might help physicians detect congestive cardiomegaly for patients undergoing portable chest AP. PMID:22065900

  15. Reynolds-Averaged Navier-Stokes Solutions to Flat Plate Film Cooling Scenarios

    Science.gov (United States)

    Johnson, Perry L.; Shyam, Vikram; Hah, Chunill

    2011-01-01

    The predictions of several Reynolds-Averaged Navier-Stokes solutions for a baseline film cooling geometry are analyzed and compared with experimental data. The Fluent finite volume code was used to perform the computations with the realizable k-epsilon turbulence model. The film hole was angled at 35 to the crossflow with a Reynolds number of 17,400. Multiple length-to-diameter ratios (1.75 and 3.5) as well as momentum flux ratios (0.125 and 0.5) were simulated with various domains, boundary conditions, and grid refinements. The coolant to mainstream density ratio was maintained at 2.0 for all scenarios. Computational domain and boundary condition variations show the ability to reduce the computational cost as compared to previous studies. A number of grid refinement and coarsening variations are compared for further insights into the reduction of computational cost. Liberal refinement in the near hole region is valuable, especially for higher momentum jets that tend to lift-off and create a recirculating flow. A lack of proper refinement in the near hole region can severely diminish the accuracy of the solution, even in the far region. The effects of momentum ratio and hole length-to-diameter ratio are also discussed.

  16. RUNX2 tandem repeats and the evolution of facial length in placental mammals

    Directory of Open Access Journals (Sweden)

    Pointer Marie A

    2012-06-01

    Full Text Available Abstract Background When simple sequence repeats are integrated into functional genes, they can potentially act as evolutionary ‘tuning knobs’, supplying abundant genetic variation with minimal risk of pleiotropic deleterious effects. The genetic basis of variation in facial shape and length represents a possible example of this phenomenon. Runt-related transcription factor 2 (RUNX2, which is involved in osteoblast differentiation, contains a functionally-important tandem repeat of glutamine and alanine amino acids. The ratio of glutamines to alanines (the QA ratio in this protein seemingly influences the regulation of bone development. Notably, in domestic breeds of dog, and in carnivorans in general, the ratio of glutamines to alanines is strongly correlated with facial length. Results In this study we examine whether this correlation holds true across placental mammals, particularly those mammals for which facial length is highly variable and related to adaptive behavior and lifestyle (e.g., primates, afrotherians, xenarthrans. We obtained relative facial length measurements and RUNX2 sequences for 41 mammalian species representing 12 orders. Using both a phylogenetic generalized least squares model and a recently-developed Bayesian comparative method, we tested for a correlation between genetic and morphometric data while controlling for phylogeny, evolutionary rates, and divergence times. Non-carnivoran taxa generally had substantially lower glutamine-alanine ratios than carnivorans (primates and xenarthrans with means of 1.34 and 1.25, respectively, compared to a mean of 3.1 for carnivorans, and we found no correlation between RUNX2 sequence and face length across placental mammals. Conclusions Results of our diverse comparative phylogenetic analyses indicate that QA ratio does not consistently correlate with face length across the 41 mammalian taxa considered. Thus, although RUNX2 might function as a ‘tuning knob’ modifying face

  17. 40 CFR Table 25 to Subpart G of... - Effective Column Diameter (Fc)

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Effective Column Diameter (Fc) 25 Table..., Table 25 Table 25 to Subpart G of Part 63—Effective Column Diameter (Fc) Column type Fc (feet) 9-inch by 7-inch built-up columns 1.1 8-inch-diameter pipe columns 0.7 No construction details known 1.0 ...

  18. First shock tuning and backscatter measurements for large case-to-capsule ratio beryllium targets

    Science.gov (United States)

    Loomis, Eric; Yi, Austin; Kline, John; Kyrala, George; Simakov, Andrei; Wilson, Doug; Ralph, Joe; Dewald, Eduard; Strozzi, David; Celliers, Peter; Millot, Marius; Tommasini, Riccardo

    2016-10-01

    The current under performance of target implosions on the National Ignition Facility (NIF) has necessitated scaling back from high convergence ratio to access regimes of reduced physics uncertainties. These regimes, we expect, are more predictable by existing radiation hydrodynamics codes giving us a better starting point for isolating key physics questions. One key question is the lack of predictable in-flight and hot spot shape due to a complex hohlraum radiation environment. To achieve more predictable, shape tunable implosions we have designed and fielded a large 4.2 case-to-capsule ratio (CCR) target at the NIF using 6.72 mm diameter Au hohlraums and 1.6 mm diameter Cu-doped Be capsules. Simulations show that at these dimensions during a 10 ns 3-shock laser pulse reaching 270 eV hohlraum temperatures, the interaction between hohlraum and capsule plasma, which at lower CCR lead to beam propagation impedance by artificial plasma stagnation, are reduced. In this talk we will present measurements of early time drive symmetry using two-axis line-imaging velocimetry (VISAR) and streaked radiography measuring velocity of the imploding shell and their comparisons to post-shot calculations using the code HYDRA (Lawrence Livermore National Laboratory).

  19. Electro-Magnetic Bunch Length Measurement in LEP

    CERN Document Server

    Vos, L

    1998-01-01

    Bunch lengths between 3 and 12 mm have been measured routinely in LEP in 1997 with a small (7 mm diameter) button electrode. The measurement method is based on the spectral analysis of the electrode signal and relies on the fact that the transfer function of the complete set-up, including the signal cable, can be computed rather exactly thus eliminating the need for external calibration. The information of beam intensity is recovered as a by-product. It provides an interesting internal validation of the measurement by comparison with the normal intensity measurement. The system has been used to detect subtle but real bunch length changes with bunch intensity which can be attributed to the inductive impedance in LEP. A value for the imaginary (inductive) longitudinal impedance is derived from the observations. An indication for the resistive part of the impedance is given as well.

  20. Effects of Nozzle Diameter on Diesel Spray Flames: A numerical study using an Eulerian Stochastic Field Method

    DEFF Research Database (Denmark)

    Pang, Kar Mun; Jangi, Mehdi; Bai, Xue-Song

    2017-01-01

    The present numerical study aims to assess the performance of an Eulerian Stochastic Field (ESF) model in simulating spray flames produced by three fuel injectors with different nozzle diameters of 100 μm, 180 μm and 363 μm. A comparison to the measurements shows that although the simulated ignit...... serve as an important tool for the simulation of spray flames in marine diesel engines, where fuel injectors with different nozzle diameters are applied for pilot and main injections.......The present numerical study aims to assess the performance of an Eulerian Stochastic Field (ESF) model in simulating spray flames produced by three fuel injectors with different nozzle diameters of 100 μm, 180 μm and 363 μm. A comparison to the measurements shows that although the simulated...... ignition delay times are consistently overestimated, the relative differences remain below 28%. Furthermore, the change of the averaged pressure rise with respect to the variation of nozzle diameter is captured by the model. The simulated flame lift-off lengths also agree with the measurements...

  1. Experimental determination of probe-length requirements for studies of the turbulent wake behind a cylinder

    International Nuclear Information System (INIS)

    Sheih, C.M.; Finnigan, J.J.; Bradley, E.F.; Mulhearn, P.J.

    1979-01-01

    The attenuation of turbulence and mean velocity signals due to the line averaging imposed by hot wires when used in the wake of an isolated circular cylinder has been investigated in a wind tunnel by measurements using several choices of hot-wire length, cylinder diameter, and freestream mean velocity. The results are presented graphically in order to provide a practical method for determining attenuation of the turbulence and mean velocity signals obtained in a wake. The length scale of the wake can be defined as L=0.6[(x-x/sub o/) d]/sup 1/2/, where x is the downstream distance from the cylinder, d is the cylinder diameter, and x/sub o/=25d. For all the wires tested, the attenuation of the measured turbulence signal is limited to within 5% only if the wire length is smaller than 0.1 L. For a wire normal to the cylinder and cross wind, the attenuation of the signal of the mean velocity-defect factor, expressed as (1-u/u/sub infinity/), where u and u/sub infinity/ are local and free-stream velocities, respectively, is less than 5% only if the wire is less than 0.5 L in length

  2. [Development of a simultaneous strain and temperature sensor with small-diameter FBG].

    Science.gov (United States)

    Liu, Rong-mei; Liang, Da-kai

    2011-03-01

    Manufacture of the small diameter FBG was designed. Cross sensitivity of temperature and strain at sensing point was solved. Based on coupled-mode theory, optical properties of the designed FBG were studied. The reflection and transmission spectra of the designed FBG in small diameter were studied A single mode optical fiber, whose cladding diameter is 80 microm, was manufactured to a fiber Bragg grating (phi80FBG). According to spectrum simulation, the grating length and period were chosen as the wavelength was 1528 nm. The connector of the small diameter FBG with demodulation was designed too. In applications, the FBG measures the total deformation including strain due to forces applied to the structures as well as thermal expansion. In order to overcome this inconvenience and to measure both parameters at the same time and location, a novel scheme for simultaneous strain and temperature sensor was presented. Since the uniform strength beam has same deformation at all points, a pair of phi80 FBG was attached on a uniform strength cantilever. One of the FBG was on the upper surface, with the other one on the below. Therefore, the strains at the monitoring points were equal in magnitude but of opposite sign. The strain and temperature in sensing point could be discriminated by matrix equation. The determination of the K is not null and thus matrix inversion is well conditioned, even the values for the K elements are close. Consequently, the cross sensitivity of the FBG with temperature and strain can be experimentally solved. Experiments were carried out to study the strain discriminability of small-diameter FBG sensors. The temperature and strain were calculated and the errors were, respectively, 5% and 6%.

  3. Effects of Titanium Oxide Nanotube Arrays with Different Lengths on the Characteristics of Dye-Sensitized Solar Cells

    Directory of Open Access Journals (Sweden)

    Chin-Guo Kuo

    2013-01-01

    Full Text Available The self-aligned highly ordered TiO2 nanotube (TNT arrays were fabricated by potentiostatic anodization of Ti foil, and we found that the TNT-array length and diameter were dependent on the electrolyte (NH4F concentration in ethylene glycol and anodization time. The characteristics of the fabricated TNT arrays were characterized by XRD pattern, FESEM, and absorption spectrum. As the electrolyte NH4F concentration in the presence of H2O (2 vol% with anodization was changed from 0.25 to 0.75 wt% and the anodization period was increased from 1 to 5 h, the TNT-array length was changed from 9.55 to 30.2 μm and the TNT-array diameter also increased. As NH4F concentration was 0.5 wt%, the prepared TNT arrays were also used to fabricate the dye-sensitized solar cells (DSSCs. We would show that the measured photovoltaic performance of the DSSCs was dependent on the TNT-array length.

  4. Stability of a short Rayleigh length laser resonator

    Directory of Open Access Journals (Sweden)

    P. P. Crooker

    2005-04-01

    Full Text Available Motivated by the prospect of constructing a short Rayleigh length free-electron laser in a high-vibration environment, we demonstrate the use of a collection of rays to study the effect of mirror vibration and distortion on the behavior of the fundamental optical mode of a cold-cavity resonator. We find that the ray collection accurately describes both on-axis and off-axis optical beams. We show that a tilt or transverse shift of a mirror causes the optical mode to rock about the original resonator axis, while a longitudinal mirror shift or a change in the mirror’s radius of curvature causes the beam diameter at a mirror to successively dilate and contract on the mirror. Results are in excellent agreement with analytic calculations and wave front propagation simulations as long as the mirrors remain large with respect to the beam diameter.

  5. Influence of obstacle aspect ratio on tripped cylinder wakes

    International Nuclear Information System (INIS)

    Araújo, Tiago B.; Sicot, Christophe; Borée, Jacques; Martinuzzi, Robert J.

    2012-01-01

    Highlights: ► Influence of a tripwire on wake properties of a surface-mounted circular cylinder. ► Height-to-diameter aspect ratios of 3 and 6 are considered. ► Critical positions for the tripwire lead to an abrupt change in the wake structure. ► Results further suggest that the tripwire can strengthen 2D wake properties. - Abstract: The influence of an asymmetrically mounted, single tripwire on the shedding and wake characteristics of a vertical, surface-mounted finite circular cylinder is investigated experimentally. Height-to-diameter aspect ratios of 3 and 6 are considered. It is shown that a critical position for the tripwire exists, which is characterised in an abrupt change in the shedding frequency and wake structure. Results further suggest that the tripwire can strengthen 2D wake properties. The influence of the aspect ratio is due to tip-wake flow interactions and thus differs fundamentally from two-dimensional geometries.

  6. Effective Debye length in closed nanoscopic systems: a competition between two length scales.

    Science.gov (United States)

    Tessier, Frédéric; Slater, Gary W

    2006-02-01

    The Poisson-Boltzmann equation (PBE) is widely employed in fields where the thermal motion of free ions is relevant, in particular in situations involving electrolytes in the vicinity of charged surfaces. The applications of this non-linear differential equation usually concern open systems (in osmotic equilibrium with an electrolyte reservoir, a semi-grand canonical ensemble), while solutions for closed systems (where the number of ions is fixed, a canonical ensemble) are either not appropriately distinguished from the former or are dismissed as a numerical calculation exercise. We consider herein the PBE for a confined, symmetric, univalent electrolyte and quantify how, in addition to the Debye length, its solution also depends on a second length scale, which embodies the contribution of ions by the surface (which may be significant in high surface-to-volume ratio micro- or nanofluidic capillaries). We thus establish that there are four distinct regimes for such systems, corresponding to the limits of the two parameters. We also show how the PBE in this case can be formulated in a familiar way by simply replacing the traditional Debye length by an effective Debye length, the value of which is obtained numerically from conservation conditions. But we also show that a simple expression for the value of the effective Debye length, obtained within a crude approximation, remains accurate even as the system size is reduced to nanoscopic dimensions, and well beyond the validity range typically associated with the solution of the PBE.

  7. Binding of plasma proteins to titanium dioxide nanotubes with different diameters

    Science.gov (United States)

    Kulkarni, Mukta; Flašker, Ajda; Lokar, Maruša; Mrak-Poljšak, Katjuša; Mazare, Anca; Artenjak, Andrej; Čučnik, Saša; Kralj, Slavko; Velikonja, Aljaž; Schmuki, Patrik; Kralj-Iglič, Veronika; Sodin-Semrl, Snezna; Iglič, Aleš

    2015-01-01

    Titanium and titanium alloys are considered to be one of the most applicable materials in medical devices because of their suitable properties, most importantly high corrosion resistance and the specific combination of strength with biocompatibility. In order to improve the biocompatibility of titanium surfaces, the current report initially focuses on specifying the topography of titanium dioxide (TiO2) nanotubes (NTs) by electrochemical anodization. The zeta potential (ζ-potential) of NTs showed a negative value and confirmed the agreement between the measured and theoretically predicted dependence of ζ-potential on salt concentration, whereby the absolute value of ζ-potential diminished with increasing salt concentrations. We investigated binding of various plasma proteins with different sizes and charges using the bicinchoninic acid assay and immunofluorescence microscopy. Results showed effective and comparatively higher protein binding to NTs with 100 nm diameters (compared to 50 or 15 nm). We also showed a dose-dependent effect of serum amyloid A protein binding to NTs. These results and theoretical calculations of total available surface area for binding of proteins indicate that the largest surface area (also considering the NT lengths) is available for 100 nm NTs, with decreasing surface area for 50 and 15 nm NTs. These current investigations will have an impact on increasing the binding ability of biomedical devices in the body leading to increased durability of biomedical devices. PMID:25733829

  8. Polymer-Carbon Nanotube Composites, A Literature Review

    National Research Council Canada - National Science Library

    Huber, Trisha A

    2004-01-01

    .... The extraordinary properties arise from the unique tubular structure; the nanotubes may be envisioned as rolled up graphene sheets that are on the order of a nanometer in diameter, and microns in length, resulting in high aspect ratios (length/diameter...

  9. Predicted singers' vocal fold lengths and voice classification-a study of x-ray morphological measures.

    Science.gov (United States)

    Roers, Friederike; Mürbe, Dirk; Sundberg, Johan

    2009-07-01

    Students admitted to the solo singing education at the University of Music Dresden, Germany have been submitted to a detailed physical examination of a variety of factors with relevance to voice function since 1959. In the years 1959-1991, this scheme of examinations included X-ray profiles of the singers' vocal tracts. This material of 132 X-rays of voice professionals was used to investigate different laryngeal morphological measures and their relation to vocal fold length. Further, the study aimed to investigate if there are consistent anatomical differences between singers of different voice classifications. The study design used was a retrospective analysis. Vocal fold length could be measured in 29 of these singer subjects directly. These data showed a strong correlation with the anterior-posterior diameter of the subglottis and the trachea as well as with the distance from the anterior contour of the thyroid cartilage to the anterior contour of the spine. These relations were used in an attempt to predict the 132 singers' vocal fold lengths. The results revealed a clear covariation between predicted vocal fold length and voice classification. Anterior-posterior subglottic-tracheal diameter yielded mean vocal fold lengths of 14.9, 16.0, 16.6, 18.4, 19.5, and 20.9mm for sopranos, mezzo-sopranos, altos, tenors, baritones, and basses, respectively. The data support the assumption that there are consistent anatomical laryngeal differences between singers of different voice classifications, which are of relevance to pitch range and timbre of the voice.

  10. Introducing Modified Degree 4 Chordal Rings with Two Chord Lengths

    DEFF Research Database (Denmark)

    Pedersen, Jens Myrup

    2007-01-01

    In this paper an analysis of modified degree 4 Chordal Rings with two chord lengths named CHRm is presented and compared to similar topologies: Chordal Rings, N2R and modified N2R. Formulas for approximating diameters and average path lengths are provided and verified, and it is shown...... that the distances in CHRm are significantly smaller than in traditional Chordal Rings and N2R, and also smaller than modified N2R for topologies with up to 1500 nodes. Despite the proposed CHRm being of degree 4, and the modified N2R of degree 3, CHRm may be better suited for the optical level of fiber rings, due...

  11. Career Choice and Unemployment Length: A Study of Graduates from a South African University

    Science.gov (United States)

    Mncayi, Precious; Dunga, Steven Henry

    2016-01-01

    Graduate unemployment is especially problematic in a country where much emphasis is placed on furthering academic studies for economic and personal rewards. This article investigates the relationship between career choice and unemployment length among graduates from a South African university. Data were collected by means of a survey questionnaire…

  12. Reduction of nanowire diameter beyond lithography limits by controlled catalyst dewetting

    International Nuclear Information System (INIS)

    Calahorra, Yonatan; Kerlich, Alexander; Gavrilov, Arkady; Cohen, Shimon; Ritter, Dan; Amram, Dor

    2016-01-01

    Catalyst assisted vapour-liquid–solid is the most common method to realize bottom-up nanowire growth; establishing a parallel process for obtaining nanoscale catalysts at pre-defined locations is paramount for further advancement towards commercial nanowire applications. Herein, the effect of a selective area mask on the dewetting of metallic nanowire catalysts, deposited within lithography-defined mask pinholes, is reported. It was found that thin disc-like catalysts, with diameters of 120–450 nm, were transformed through dewetting into hemisphere-like catalysts, having diameters 2–3 fold smaller; the process was optimized to about 95% yield in preventing catalyst splitting, as would otherwise be expected due to their thickness-to-diameter ratio, which was as low as 1/60. The catalysts subsequently facilitated InP and InAs nanowire growth. We suggest that the mask edges prevent surface migration mediated spreading of the dewetted metal, and therefore induce its agglomeration into a single particle. This result presents a general strategy to diminish lithography-set dimensions for NW growth, and may answer a fundamental challenge faced by bottom-up nanowire technology. (paper)

  13. Bark thickness related to tree diameter in sugar maple (Acer saccharum Marsh.)

    Science.gov (United States)

    H. Clay Smith

    1969-01-01

    Bark thickness for sugar maple trees in Vermont was found to be related to tree diameter at breast height (d.b.h.). The relationship was positive-as the diameter increased, the bark thickness increased.

  14. Investor reaction to strategic emphasis on earnings numbers: An empirical study

    Directory of Open Access Journals (Sweden)

    M. Shibley Sadique

    2013-10-01

    Full Text Available We analyze the earnings information and stock prices of S&P500 firms and find that investors following S&P500 stocks (i respond more to pro forma earnings than to GAAP earnings, (ii respond to an emphasis on pro forma earnings, and (iii are fixated on pro forma earnings. We provide the first direct evidence that a strategic emphasis on earnings numbers may affect return volatility. Further, our results do not support the argument that a larger investor response to Street earnings might be driven by large differences between the Street numbers and GAAP numbers.

  15. Sensitivity optimization of ZnO clad-modified optical fiber humidity sensor by means of tuning the optical fiber waist diameter

    Science.gov (United States)

    Azad, Saeed; Sadeghi, Ebrahim; Parvizi, Roghaieh; Mazaheri, Azardokht; Yousefi, M.

    2017-05-01

    In this work, the multimode optical fiber size effects on the performances of the clad-modified fiber with ZnO nanorods relative humidity (RH) sensor were experimentally investigated. Simple and controlled chemical etching method through on line monitoring was used to prepare different fiber waist diameter with long length of 15 mm. More precisely, the competition behavior of sensor performances with varying fiber waist diameter was studied to find appropriate size of maximizing evanescent fields. The obtained results revealed that evanescent wave absorption coefficient (γ) enhanced more than 10 times compare to bare fiber at the proposed optimum fiber diameter of 28 μm. Also, high linearity and fast recovery time about 7 s was obtained at the proposed fiber waist diameter. Applicable features of the proposed sensor allow this device to be used for humidity sensing applications, especially to be applied in remote sensing technologies.

  16. Leak Detection in Water-Filled Small-Diameter Polyethylene Pipes by Means of Acoustic Emission Measurements

    Directory of Open Access Journals (Sweden)

    Alberto Martini

    2016-12-01

    Full Text Available The implementation of effective strategies to manage leaks represents an essential goal for all utilities involved with drinking water supply in order to reduce water losses affecting urban distribution networks. This study concerns the early detection of leaks occurring in small-diameter customers’ connections to water supply networks. An experimental campaign was carried out in a test bed to investigate the sensitivity of Acoustic Emission (AE monitoring to water leaks. Damages were artificially induced on a polyethylene pipe (length 28 m, outer diameter 32 mm at different distances from an AE transducer. Measurements were performed in both unburied and buried pipe conditions. The analysis permitted the identification of a clear correlation between three monitored parameters (namely total Hits, Cumulative Counts and Cumulative Amplitude and the characteristics of the examined leaks.

  17. Radiographic diagnosis of mechanical obstruction in dogs based on relative small intestinal external diameters.

    Science.gov (United States)

    Finck, Cyrielle; D'Anjou, Marc-André; Alexander, Kate; Specchi, Swan; Beauchamp, Guy

    2014-01-01

    Mechanical obstruction is a frequent cause of acute vomiting in dogs requiring prompt diagnosis to improve patient management and prognosis. The purpose of this retrospective study was to compare small intestinal radiographic characteristics in dogs with versus without mechanical intestinal obstruction. Fifty dogs with gastrointestinal clinical signs and abdominal radiographs were recruited from hospital record archives and assigned to groups (group 1, obstructive, n = 25; group 2, nonobstructive n = 25). Abdominal radiographs were randomized and independently interpreted by three examiners who were unaware of group status. Intestinal dilation was subjectively scored based on distribution (segmental, regional or diffuse), and severity (absent, mild, moderate or severe). Small intestinal maximal diameter (SImax), L5 vertebral body height, small intestinal minimal diameter (SImin), and an estimated average of small intestinal diameters (SIave) were measured and three ratios were calculated: SImax/L5, SImax/SImin, and SImax/SIave. Segmental dilation was more prevalent in obstructed dogs for all examiners (P ≤ 0.03) and most nonobstructed dogs had no dilation (P ≤ 0.05). All ratios were higher in obstructed dogs (P dogs with SImax/L5 ≤ 1.4, SImax/SImin ≤ 2, and SImax/SIave ≤ 1.3 values are very unlikely to be mechanically obstructed; dogs with SImax/L5 ≥ 2.4, SImax/SImin ≥ 3.4 and SImax/SIave ≥ 1.9 are very likely obstructed, particularly if segmental dilation (less than 25% of the small intestine) is present. Dogs with ratios falling between these thresholds may need further testing unless other signs justify surgical exploration or endoscopy. © 2014 American College of Veterinary Radiology.

  18. Relationship between the Apical Preparation Diameter and the Apical Seal: An In Vitro Study

    Directory of Open Access Journals (Sweden)

    Kaoutar Laslami

    2018-01-01

    Full Text Available Objectives. The aim of the study is to define the relationship between the apical preparation diameter and the apical sealing ability to highlight the importance of the preservation of the diameter and the original position of the apical foramen. Materials and Methods. 50 extracted maxillary incisors were randomly allocated into three groups of 15 teeth each (n = 15 according to the apical preparation size: Group 1: finishing file F1 corresponding to size 20 reached the working length (ProTaper Universal system Dentsply®; Group 2: prepared up to size 30 corresponding to finishing file F30; Group 3: prepared up to size 50 corresponding to finishing file F5. Five teeth were assigned to positive and negative control groups. After the filling of the root canals, the teeth were isolated and immersed in a dye solution, then cut longitudinally, photographed, and the dye penetration were calculated using a computer software. Results. Comparison of the three different apical preparation sizes showed no statistically significant differences regarding the apical microleakage. Conclusion. The most important value of the dye penetration was observed in the group with the largest apical diameter.

  19. Impact of Cyclic Prefix length on OFDM system Capacity

    DEFF Research Database (Denmark)

    Rom, Christian; Sørensen, Troels Bundgaard; Mogensen, Preben Elgaard

    2005-01-01

    This paper is a study on the impact of the Cyclic Prefix (CP) length on the downlink Capacity in a base-band synchronized SISO-OFDM context. To measure this impact, the capacity, measured in bits per second per hertz, is chosen as quality parameter. The study shows how the lengthening of the CP......) the useful OFDM symbol duration, 2) the Signal to Noise Ratio (SNR) at the receiver and 3) the channel Power Delay Profile (PDP). Depending on the values of these parameters different optimum CP lengths are obtained. For a system using only one value of CP length we suggest an optimum value to be 4us...... for an OFDM symbol length of 40us and 6us for an OFDM symbol length of 80us....

  20. Modification of Hack Saw Blade Support 'REMOR 400' from the Length of 650 mm to 450 mm

    International Nuclear Information System (INIS)

    Sagino, Abdul-Hafid

    2005-01-01

    REMOR 400 type is the hack saw machine for cutting large work piece. The capacity of cutting is 310 mm diameter. The length of the blade is 650 mm (26 inches). For cutting small work piece (≤ 150 mm), the use of this blade is not efficient because the blade is relatively expensive. To solve this problem, the modification of the blade support is performed so that REMOR 400 machine can use the blade of 450 mm which is cheaper and easier to find in the market. (author)

  1. Unzipping of multi-wall carbon nanotubes with different diameter distributions: Effect on few-layer graphene oxide obtention

    Science.gov (United States)

    Torres, D.; Pinilla, J. L.; Suelves, I.

    2017-12-01

    Few-layer graphene oxide (FLGO) was obtained by chemical unzipping of multi-wall carbon nanotubes (MWCNT) of different diameter distributions. MWCNT were synthesized by catalytic decomposition of methane using Fe-Mo/MgO catalysts. The variation in the Fe/Mo ratio (1, 2 and 5) was very influential in MWCNT diameter distribution and type of MWCNT obtained, including textural, chemical, structural and morphological characteristics. MWCNT diameter distribution and surface defects content had a profound impact on the characteristics of the resulting FLGO. Thus, MWCNT obtained with the catalyst with a Fe/Mo: 5 and presenting a narrow diameter distribution centered at 8.6 ± 3.3 nm led to FLGO maintaining non-oxidized graphite stacking (according to XRD analysis), lower specific surface area and higher thermostability as compared to FLGO obtained from MWCNT showing wider diameter distributions. The presence of more oxygen-containing functionalities and structural defects in large diameter nanotubes promotes the intercalation of species towards the inner layers of the nanotube, resulting in an enhanced MWCNT oxidation and opening into FLGO, what improves both micro- and mesoporosity.

  2. The effect of maternity leave length and time of return to work on breastfeeding.

    Science.gov (United States)

    Ogbuanu, Chinelo; Glover, Saundra; Probst, Janice; Liu, Jihong; Hussey, James

    2011-06-01

    We investigated the effect of maternity leave length and time of first return to work on breastfeeding. Data were from the Early Childhood Longitudinal Study-Birth Cohort. Restricting our sample to singletons whose biological mothers were the respondents at the 9-month interview and worked in the 12 months before delivery (N = 6150), we classified the length of total maternity leave (weeks) as 1 to 6, 7 to 12, ≥ 13, and did not take; paid maternity leave (weeks) as 0, 1 to 6, ≥ 7, and did not take; and time of return to work postpartum (weeks) as 1 to 6, 7 to 12, ≥ 13, and not yet returned. Analyses included χ(2) tests and multiple logistic regressions. In our study population, 69.4% initiated breastfeeding with positive variation by both total and paid maternity leave length, and time of return to work. In adjusted analyses, neither total nor paid maternity leave length had any impact on breastfeeding initiation or duration. Compared with those returning to work within 1 to 6 weeks, women who had not yet returned to work had a greater odds of initiating breastfeeding (odds ratio [OR]: 1.46 [1.08-1.97]; risk ratios [RR]: 1.13 [1.03-1.22]), continuing any breastfeeding beyond 6 months (OR: 1.41 [0.87-2.27]; RR: 1.25 [0.91-1.61]), and predominant breastfeeding beyond 3 months (OR: 2.01 [1.06-3.80]; RR: 1.70 [1.05-2.53]). Women who returned to work at or after 13 weeks postpartum had higher odds of predominantly breastfeeding beyond 3 months (OR: 2.54 [1.51-4.27]; RR: 1.99 [1.38-2.69]). If new mothers delay their time of return to work, then duration of breastfeeding among US mothers may lengthen.

  3. In vitro cytotoxicity of Manville Code 100 glass fibers: Effect of fiber length on human alveolar macrophages

    Directory of Open Access Journals (Sweden)

    Jones William

    2006-03-01

    Full Text Available Abstract Background Synthetic vitreous fibers (SVFs are inorganic noncrystalline materials widely used in residential and industrial settings for insulation, filtration, and reinforcement purposes. SVFs conventionally include three major categories: fibrous glass, rock/slag/stone (mineral wool, and ceramic fibers. Previous in vitro studies from our laboratory demonstrated length-dependent cytotoxic effects of glass fibers on rat alveolar macrophages which were possibly associated with incomplete phagocytosis of fibers ≥ 17 μm in length. The purpose of this study was to examine the influence of fiber length on primary human alveolar macrophages, which are larger in diameter than rat macrophages, using length-classified Manville Code 100 glass fibers (8, 10, 16, and 20 μm. It was hypothesized that complete engulfment of fibers by human alveolar macrophages could decrease fiber cytotoxicity; i.e. shorter fibers that can be completely engulfed might not be as cytotoxic as longer fibers. Human alveolar macrophages, obtained by segmental bronchoalveolar lavage of healthy, non-smoking volunteers, were treated with three different concentrations (determined by fiber number of the sized fibers in vitro. Cytotoxicity was assessed by monitoring cytosolic lactate dehydrogenase release and loss of function as indicated by a decrease in zymosan-stimulated chemiluminescence. Results Microscopic analysis indicated that human alveolar macrophages completely engulfed glass fibers of the 20 μm length. All fiber length fractions tested exhibited equal cytotoxicity on a per fiber basis, i.e. increasing lactate dehydrogenase and decreasing chemiluminescence in the same concentration-dependent fashion. Conclusion The data suggest that due to the larger diameter of human alveolar macrophages, compared to rat alveolar macrophages, complete phagocytosis of longer fibers can occur with the human cells. Neither incomplete phagocytosis nor length-dependent toxicity was

  4. Abortion trends from 1996 to 2011 in Estonia: special emphasis on repeat abortion

    Science.gov (United States)

    2014-01-01

    Background The study aimed to describe the overall and age-specific trends of induced abortions from 1996 to 2011 with an emphasis on socio-demographic characteristics and contraceptive use of women having had repeat abortions in Estonia. Methods Data were retrieved from the Estonian Medical Birth and Abortion Registry and Statistics Estonia. Total induced abortion numbers, rates, ratios and age-specific rates are presented for 1996–2011. The percentage change in the number of repeat abortions within selected socio-demographic subgroups, contraception use and distribution of induced abortions among Estonians and non-Estonians for the first, second, third, fourth and subsequent abortions were calculated for the periods 1996–2003 and 2004–2011. Results Observed trends over the 16-year study period indicated a considerable decline in induced abortions with a reduction in abortion rate of 57.1%, which was mainly attributed to younger cohorts. The percentage of women undergoing repeat abortions fell steadily from 63.8% during 1996–2003 to 58.0% during 2004–2011. The percentage of women undergoing repeat abortions significantly decreased over the 16 years within all selected socio-demographic subgroups except among women with low educational attainment and students. Within each time period, a greater percentage of non-Estonians than Estonians underwent repeat abortions and obtained third and subsequent abortions. Most women did not use any contraceptive method prior to their first or subsequent abortion. Conclusion A high percentage of women obtaining repeat abortions reflects a high historical abortion rate. If current trends continue, a rapid decline in repeat abortions may be predicted. To decrease the burden of sexual ill health, routine contraceptive counselling, as standard care in the abortion process, should be seriously addressed with an emphasis on those groups - non-Estonians, women with lower educational attainment, students and women with children

  5. Reproductive characteristics and the weight-length relationship in Anableps anableps (Linnaeus, 1758 (Cyprinodontiformes: Anablepidae from the Amazon Estuary

    Directory of Open Access Journals (Sweden)

    Valéria de Albuquerque Oliveira

    Full Text Available The present study analyzed the length-weight relationship and some aspects of the reproductive biology of Anableps anableps from the mouth of the Maracanã River, in the Brazilian state of Pará. The specimens were collected using two 30 m-long gillnets with 15 and 20 mm mesh size, as well as a 1 m-diameter hand net with a 10 mm mesh. A total of 865 specimens were collected, from which an adult sex ratio of 2.12 females per male was recorded (χ² = 13.07; p<0.05. Females presented positively allometric growth, whereas males were negatively allometric. In the additional analyses, the gonads of 371 female specimens were observed microscopically. Gonadal development was classified in three stages: immature (5.0%, maturing (12.0%, and mature (83.0%. Embryonic development was classified in five phases, according to the size of the embryo and the vitelline sac. Mean fecundity was 12 eggs/embryos per female (range: 1-37 eggs/embryos. A significant relationship was recorded between the standard length of females and ovaries weight (R² = 0.257; p < 0.001, and the number of embryos carried (R² = 0.573; p < 0.001. Mean body length of females at initial sexual maturation (L50 was estimated at 11.7 cm. The species reproduced throughout the year.

  6. Anatomic and hemodynamic evaluation of renal venous flow in varicocele formation using color Doppler sonography with emphasis on renal vein entrapment syndrome.

    Science.gov (United States)

    Unlu, Murat; Orguc, Sebnem; Serter, Selim; Pekindil, Gokhan; Pabuscu, Yuksel

    2007-01-01

    To investigate the anatomic and hemodynamic properties of testicular venous drainage and its effects on varicocele formation and reflux using color Doppler ultrasound (US) with emphasis on renal vein entrapment syndrome. Upper abdominal and scrotal US examinations of 35 varicocele patients and 35 healthy male subjects were performed in the supine position during rest, during a Valsalva maneuver and in the erect position. The aortomesenteric angle and distance (AMA and AMD, respectively), peak mean velocities (PVs) and diameters of different segments of renal veins, testicular vein diameters and duration of flow inversion were measured. In the varicocele group, the lateral segment of the left renal vein (LRV) had a larger diameter and slower PV, and the medial segment of the LRV had a smaller diameter and faster PV. The diameter of the dominant draining vein correlated with the PV of the medial and lateral segments of the LRV, whereas there was no correlation between the diameter of the dominant draining vein and the diameters of the right renal vein (RRV) and the lateral segment of the LRV or the PV of the RRV. The duration of flow inversion correlated with the diameter and PV of the medial segment of the LRV. No correlation between the diameters and PVs of the RRV and the lateral segment of the LRV was detected. The decreases in the AMA, AMD, diameter of the medial segment of the LRV and PV of the lateral segment of the LRV, and the increases in the PV of the medial segment of the LRV and the diameter of the lateral segment of the LRV in varicocele patients in all positions suggest the entrapment or impingement of the left renal vein between the aorta and the superior mesenteric artery. This has been defined as the "nutcracker phenomenon", which is known to affect varicocele formation.

  7. Biomass estimates of freshwater zooplankton from length-carbon regression equations

    Directory of Open Access Journals (Sweden)

    Patrizia COMOLI

    2000-02-01

    Full Text Available We present length/carbon regression equations of zooplankton species collected from Lake Maggiore (N. Italy during 1992. The results are discussed in terms of the environmental factors, e.g. food availability, predation, controlling biomass production of particle- feeders and predators in the pelagic system of lakes. The marked seasonality in the length-standardized carbon content of Daphnia, and its time-specific trend suggest that from spring onward food availability for Daphnia population may be regarded as a simple decay function. Seasonality does not affect the carbon content/unit length of the two predator Cladocera Leptodora kindtii and Bythotrephes longimanus. Predation is probably the most important regulating factor for the seasonal dynamics of their carbon biomass. The existence of a constant factor to convert the diameter of Conochilus colonies into carbon seems reasonable for an organism whose population comes on quickly and just as quickly disappears.

  8. Pupil to limbus ratio: Introducing a simple objective measure using two-box method for measuring early anisocoria and progress of pupillary change in the ICU

    Directory of Open Access Journals (Sweden)

    Deb Kumar Mojumder

    2015-01-01

    Full Text Available Introduction: Measurement of static pupillary size in the ICU is of importance in cases of acutely expanding intracranial mass lesions. The inaccuracies with subjective assessment of pupillary size by medical personnel preclude its use in emergent neurological situations. Objective: To determine if the ratio of pupil to limbus diameter (PLD ratio measured by a two-box method is a reliable measure of pupil size for detecting early anisocoria and measuring pupillary changes. Materials and Methods: The PLD ratio was defined as the ratio of the pupillary diameter measured at a para-horizontal axial plane with the limbus diameter measured at the same or parallel axial plane. A two-box method was used to estimate the diameters of imaged pupils. Eyes were imaged using an iPhone 4S cellphone camera. Background illumination was measured and kept constant. The pupils of a 78-year-old woman, who presented with a large intra-axial parenchymal hemorrhage, were imaged. The patient had left pupillary miosis in dark but not in bright light. After presenting this case along with the images of the pupillary examination, a group of 21 medical staff were asked several questions on the pupillary examination. Reliability of PLD ratio were assessed via standard error of mean (S.E.M of PLD ratios for 3 different subjects each imaged under constant illumination and fixation but from different angles to the optical axis. Results: Analysis of questionnaire data together with PLD ratios revealed that ~ 14% and 10% of participants could estimate the pupillary size in darkness and bright light respectively but none were simultaneously accurate indicating that subjective assessment of pupillary size was unreliable. The approach towards a systematic pupillary examination was inconsistent among the participants. The PLD ratio was found to be a reliable measure of pupillary size with standard error of mean below 0.1 mm for the three subjects tested. Conclusion: Static pupillary

  9. Estimation of Flow Channel Parameters for Flowing Gas Mixed with Air in Atmospheric-pressure Plasma Jets

    Science.gov (United States)

    Yambe, Kiyoyuki; Saito, Hidetoshi

    2017-12-01

    When the working gas of an atmospheric-pressure non-equilibrium (cold) plasma flows into free space, the diameter of the resulting flow channel changes continuously. The shape of the channel is observed through the light emitted by the working gas of the atmospheric-pressure plasma. When the plasma jet forms a conical shape, the diameter of the cylindrical shape, which approximates the conical shape, defines the diameter of the flow channel. When the working gas flows into the atmosphere from the inside of a quartz tube, the gas mixes with air. The molar ratio of the working gas and air is estimated from the corresponding volume ratio through the relationship between the diameter of the cylindrical plasma channel and the inner diameter of the quartz tube. The Reynolds number is calculated from the kinematic viscosity of the mixed gas and the molar ratio. The gas flow rates for the upper limit of laminar flow and the lower limit of turbulent flow are determined by the corresponding Reynolds numbers estimated from the molar ratio. It is confirmed that the plasma jet length and the internal plasma length associated with strong light emission increase with the increasing gas flow rate until the rate for the upper limit of laminar flow and the lower limit of turbulent flow, respectively. Thus, we are able to explain the increasing trend in the plasma lengths with the diameter of the flow channel and the molar ratio by using the cylindrical approximation.

  10. Second to fourth digit ratio: a predictor of adult lung function

    Directory of Open Access Journals (Sweden)

    I-Nae Park

    2014-02-01

    Full Text Available Sex and sex hormones play a major role in lung physiology. It has been proposed that the ratio of the second to fourth digits (digit ratio is correlated with fetal sex hormones. We therefore hypothesized that digit ratio might help predict lung function. We investigated the relationship between digit ratio and pulmonary function test (PFT fi ndings. A total of 245 South Korean patients (162 male, 83 female aged from 34 to 90 years who were hospitalized for urological surgery were prospectively enrolled. Before administering the PFTs, the lengths of the second and fourth digits of the right hand were measured by a single investigator using a digital Vernier caliper. In males (n = 162, univariate and multivariate analysis using linear regression models showed that digit ratio was a signifi cant predictive factor of forced vital capacity (FVC and forced expiratory volume in 1 second (FEV1 (FVC: r = 0.156, P = 0.047; FEV1: r = 0.160, P = 0.042. In male ever-smokers (n = 69, lung functions (FVC and FEV1 were correlated with smoking exposure rather than digit ratio. In female never-smokers (n = 83, lung functions (FEV1 and FEV1/FVC ratio were positively correlated with digit ratio on univariate analysis (FEV1: r = 0.242, P = 0.027; FEV1/FVC ratio: r = 0.245, P = 0.026. Patients with lower digit ratios tend to have decreased lung function. These results suggest that digit ratio is a predictor of airway function.

  11. Transferability of decompression wave speed measured by a small-diameter shock tube to full size pipelines and implications for determining required fracture propagation resistance

    International Nuclear Information System (INIS)

    Botros, K.K.; Geerligs, J.; Rothwell, Brian; Carlson, Lorne; Fletcher, Leigh; Venton, Philip

    2010-01-01

    The control of propagating ductile (or tearing) fracture is a fundamental requirement in the fracture control design of pipelines. The Battelle two-curve method developed in the early 1970s still forms the basis of the analytical framework used throughout the industry. GASDECOM is typically used for calculating decompression speed, and idealizes the decompression process as isentropic and one-dimensional, taking no account of frictional effects. While this approximation appears not to have been a major issue for large-diameter pipes and for moderate pressures (up to 12 MPa), there have been several recent full-scale burst tests at higher pressures and smaller diameters for which the measured decompression velocity has deviated progressively from the predicted values, in general towards lower velocities. The present research was focused on determining whether pipe diameter was a major factor that could limit the applicability of frictionless models such as GASDECOM. Since potential diameter effects are primarily related to wall friction, which in turn is related to the ratio of surface roughness-to-diameter, an experimental approach was developed based on keeping the diameter constant, at a sufficiently small value to allow for an economical experimental arrangement, and varying the internal roughness. A series of tests covering a range of nominal initial pressures from 10 to 21 MPa, and involving a very lean gas and three progressively richer compositions, were conducted using two specialized high-pressure shock tubes (42 m long, I.D. = 38.1 mm). The first is honed to an extremely smooth surface finish, in order to minimize frictional effects and better simulate the behaviour of larger-diameter pipelines, while the second has a higher internal surface roughness. The results show that decompression wave speeds in the rough tube are consistently slower than those in the smooth tube under the same conditions of mixture composition and initial pressure and temperature

  12. Effect of TiO2 nanotube length and lateral tubular spacing on ...

    Indian Academy of Sciences (India)

    Abstract. The main objective of this study is to show the effect of TiO2 nanotube length, diameter and intertubular ... formation of nanotube arrays spread uniformly over a large area. ... 36, 48 and 72 h at an applied voltage of 40 V. The anodized ... and phase analysis for the obtained nanotubes were done .... Using an extra-.

  13. Surface tension of droplets and Tolman lengths of real substances and mixtures from density functional theory

    Science.gov (United States)

    Rehner, Philipp; Gross, Joachim

    2018-04-01

    The curvature dependence of interfacial properties has been discussed extensively over the last decades. After Tolman published his work on the effect of droplet size on surface tension, where he introduced the interfacial property now known as Tolman length, several studies were performed with varying results. In recent years, however, some consensus has been reached about the sign and magnitude of the Tolman length of simple model fluids. In this work, we re-examine Tolman's equation and how it relates the Tolman length to the surface tension and we apply non-local classical density functional theory (DFT) based on the perturbed chain statistical associating fluid theory (PC-SAFT) to characterize the curvature dependence of the surface tension of real fluids as well as mixtures. In order to obtain a simple expression for the surface tension, we use a first-order expansion of the Tolman length as a function of droplet radius Rs, as δ(Rs) = δ0 + δ1/Rs, and subsequently expand Tolman's integral equation for the surface tension, whereby a second-order expansion is found to give excellent agreement with the DFT result. The radius-dependence of the surface tension of increasingly non-spherical substances is studied for n-alkanes, up to icosane. The infinite diameter Tolman length is approximately δ0 = -0.38 Å at low temperatures. For more strongly non-spherical substances and for temperatures approaching the critical point, however, the infinite diameter Tolman lengths δ0 turn positive. For mixtures, even if they contain similar molecules, the extrapolated Tolman length behaves strongly non-ideal, implying a qualitative change of the curvature behavior of the surface tension of the mixture.

  14. The Relationship amongst Intervertebral Disc Vertical Diameter, Lateral Foramen Diameter and Nerve Root Impingement in Lumbar Vertebra

    Directory of Open Access Journals (Sweden)

    Yusof MI

    2018-03-01

    Full Text Available Introduction: The vertical diameter of the foramen is dependent upon the vertical diameter of the corresponding intervertebral disc. A decrease in disc vertical diameter has direct anatomic consequences to the foraminal diameter and area available for the nerve root passing through it. This study is to establish the relationship amongst the intervertebral disc vertical diameter, lateral foramen diameters and nerve root compression in the lumbar vertebra. Materials and Methods: Measurements of the study parameters were performed using sagittal MRI images. The parameters studied were: intervertebral disc vertical diameter (DVD, foraminal vertical diameter (FVD, foraminal transverse diameter (FTD and nerve root diameter (NRD of both sides. The relationship between the measured parameters were then analyzed. Results: A total of 62 MRI images were available for this study. Statistical analysis showed moderate to strong correlation between DVD and FVD at all the lumbar levels except at left L23 and L5S1 and right L3L4 and L4L5. Correlation between DVD and FTD were not significant at all lumbar levels. Regression analysis showed that a decrease of 1mm of DVD was associated with 1.3, 1.7, 3.3, 3.3 and 1.3mm reduction of FVD at L1L2, L2L3, L3L4, L4L5 and L5S1 respectively. Conclusion: Reduction of DVD was associated with reduction of FVD. However, FVD was relatively wide for the nerve root even with complete loss of DVD. FTD was much narrower than the FVD making it more likely to cause nerve root compression at the exit foramina. These anatomical details should be given consideration in treating patients with lateral canal stenosis.

  15. Pile load test on large diameter steel pipe piles in Timan-Pechora, Russia

    Energy Technology Data Exchange (ETDEWEB)

    McKeown, S. [Golder Associates Inc., Houston, TX (United States); Tart, B. [Golder Associates Inc., Anchorage, AK (United States); Swartz, R. [Paragon Engineering Services Inc., Houston, TX (United States)

    1994-12-31

    Pile load testing conducted in May and June of 1993 at the Polar Lights Ardalin project in Arkangelsk province, Russia, was documented. Pile load testing was conducted to determine the ultimate and allowable pile loads for varying pile lengths and ground temperature conditions and to provide creep test data for deformation under constant load. The piles consisted of 20 inch diameter steel pipe piles driven open ended through prebored holes into the permafrost soils. Ultimate pile capacities, adfreeze bond, and creep properties observed were discussed. 10 figs., 4 tabs.

  16. High yield polyol synthesis of round- and sharp-end silver nanowires with high aspect ratio

    Energy Technology Data Exchange (ETDEWEB)

    Nekahi, A.; Marashi, S.P.H., E-mail: pmarashi@aut.ac.ir; Fatmesari, D. Haghshenas

    2016-12-01

    Long silver nanowires (average length of 28 μm, average aspect ratio of 130) with uniform diameter along their length were produced by polyol synthesis of AgNO{sub 3} in ethylene glycol in the presence of PVP as preferential growth agent. Nanowires were produced with no addition of chloride salts such as NaCl or CuCl{sub 2} (or other additives such as Na{sub 2}S) which are usually used for lowering reduction rate of Ag ions by additional etchant of O{sub 2}/Cl{sup −}. Lower reduction rate was obtained by increasing the injection time of PVP and AgNO{sub 3} solutions, which was the significant factor in the formation of nanowires. Therefore, there was enough time for reduced Ag atoms to be deposited preferentially in the direction of PVP chains, resulting in high yield (the fraction of nanowires in the products) of nanowires (more than 95%) with high aspect ratio. The produced nanowires had both round- and sharp-ends with pentagonal cross section. Higher energy level of Ag atoms in borders of MTPs, which increases the dissolution rate of precipitated atoms, in addition to partial melting of MTPs at high synthesis temperatures, leads to the curving of the surfaces of exposed (111) crystalline planes in some MTPs and the formation of round-end silver nanowires. - Highlights: • Long silver nanowires with high aspect ratio of 130 were produced. • More than 95% nanowires were produced in products. • The produced nanowires had round- and sharp-ends with pentagonal cross section. • Additives were needed neither for high yield synthesis nor for round-end nanowires. • Melting and etching of MTPs in high energy borders resulted to round-end nanowires.

  17. The Effect of Height, Wing Length, and Wing Symmetry on Tabebuia rosea Seed Dispersal

    Directory of Open Access Journals (Sweden)

    Yasmeen Moussa

    2014-12-01

    Full Text Available The relationship between the vertical drop height and the horizontal distance traveled (dispersal ratio was investigated for a sample of fifty Tabebuia rosea seeds by dropping the seeds from five heights ranging from 1.00 to 2.00 meters. The dispersal ratio was found to be a constant 0.16 m/m for these heights. The effects of total seed length and asymmetry of seed wings on dispersal ratio were also measured using separate samples of fifty Tabebuia rosea seeds. It was found that neither seed length nor asymmetry had a significant effect on the dispersal ratio.

  18. Effects of prenatal Leydig cell function on the ratio of the second to fourth digit lengths in school-aged children.

    Directory of Open Access Journals (Sweden)

    Takahiko Mitsui

    Full Text Available Prenatal sex hormones can induce abnormalities in the reproductive system and adversely impact on genital development. We investigated whether sex hormones in cord blood influenced the ratio of the second to fourth digit lengths (2D/4D in school-aged children. Of the 514 children who participated in a prospective cohort study on birth in Sapporo between 2002 and 2005, the following sex hormone levels were measured in 294 stored cord blood samples (135 boys and 159 girls; testosterone (T, estradiol (E, progesterone, LH, FSH, inhibin B, and insulin-like factor 3 (INSL3. A total of 350 children, who were of school age and could be contacted for this survey, were then requested via mail to send black-and-white photocopies of the palms of both the left and right hands. 2D/4D was calculated in 190 children (88 boys and 102 girls using photocopies and derived from participants with the characteristics of older mothers, a higher annual household income, higher educational level, and fewer smokers among family members. 2D/4D was significantly lower in males than in females (p<0.01. In the 294 stored cord blood samples, T, T/E, LH, FSH, Inhibin B, and INSL3 levels were significantly higher in samples collected from males than those from females. A multivariate regression model revealed that 2D/4D negatively correlated with INSL3 in males and was significantly higher in males with <0.32 ng/mL of INSL3 (p<0.01. No correlations were observed between other hormones and 2D/4D. In conclusion, 2D/4D in school-aged children, which was significantly lower in males than in females, was affected by prenatal Leydig cell function.

  19. Measurements of Turbulent Flame Speed and Integral Length Scales in a Lean Stationary Premixed Flame

    OpenAIRE

    Klingmann, Jens; Johansson, Bengt

    1998-01-01

    Turbulent premixed natural gas - air flame velocities have been measured in a stationary axi-symmetric burner using LDA. The flame was stabilized by letting the flow retard toward a stagnation plate downstream of the burner exit. Turbulence was generated by letting the flow pass through a plate with drilled holes. Three different hole diameters were used, 3, 6 and 10 mm, in order to achieve different turbulent length scales. Turbulent integral length scales were measured using two-point LD...

  20. Effects of Diameter on Initial Stiffness of P-Y Curves for Large-Diameter Piles in Sand

    DEFF Research Database (Denmark)

    Sørensen, Søren Peder Hyldal; Ibsen, Lars Bo; Augustesen, Anders Hust

    2010-01-01

    is developed for slender piles with diameters up to approximately 2.0 m. Hence, the method is not validated for piles with diameters of 4–6 m. The aim of the paper is to extend the p-y curve method to large-diameter non-slender piles in sand by considering the effects of the pile diameter on the soil-pile...... interaction. Hence, a modified expression for the p-y curves for statically loaded piles in sand is proposed in which the initial slope of the p-y curves depends on the depth below the soil surface, the pile diameter and the internal angle of friction. The evaluation is based on three-dimensional numerical...... analyses by means of the commercial program FLAC3D incorporating a Mohr-Coulomb failure criterion. The numerical model is validated with laboratory tests in a pressure tank at Aalborg University....

  1. Large diameter interseam boreholes: their usage to improve underground environments

    Energy Technology Data Exchange (ETDEWEB)

    Pickering, A.J. (Nottingham University, Nottingham (United Kingdom). Dept. of Mineral Resources Engineering)

    1993-07-01

    Development of drilling techniques for larger diameter holes over the last fifteen years has indicated their considerable potential to assist with quickly improving environmental facilities and services to high output coal faces. In Nottinghamshire, as well as in several other regions, mines have utilised interseam boreholes, fully lined, to improve inbye air flows with subsequent reduction of face temperatures, dust and firedamp levels. Some further holes have additionally been adapted quickly to increase firedamp drainage capacities and also to improve service facilities such as compressed air, electrical power and water, and access. A wide range of borehole sizes are employed, ranging from 0.35 m, with integral steel lining, up to a maximum of 2.5 m in diameter, fully concrete lined. The Nottinghamshire Group Sinking and Tunnelling Engineer provides a full range of drilling facilities. The most popular large diameter holes with a potential of 1.8 m in diameter, over 200 m in vertical depth, employs a Robins, type 23R, raise borer which has been in use up and down the country since 1977. A Fosroc CGR10 type, techgrout is applied after boring is completed to provide the essential smooth lining. The application of this lining utilises a special rubber former developed locally, essentially knitting strata cracks, beddings and any local overbreak of the holes. The former or 'sausage' is used in a similar manner to correct and repair boreholes which have been in use for some time. 4 refs., 6 figs., 1 tab.

  2. Assessing colonic anatomy normal values based on air contrast enemas in children younger than 6 years.

    Science.gov (United States)

    Koppen, Ilan J N; Yacob, Desale; Di Lorenzo, Carlo; Saps, Miguel; Benninga, Marc A; Cooper, Jennifer N; Minneci, Peter C; Deans, Katherine J; Bates, D Gregory; Thompson, Benjamin P

    2017-03-01

    Contrast enemas with barium or water-soluble contrast agents are sometimes performed in children with severe intractable constipation to identify anatomical abnormalities. However there are no clear definitions for normal colonic size or abnormalities such as colonic dilation or sigmoid redundancy in children. To describe characteristics of colonic anatomy on air contrast enemas in children without constipation to provide normal values for colonic size ratios in children. We performed a retrospective chart review of children aged 0-5 years who had undergone air contrast enemas for intussusception. The primary outcome measures were the ratios of the diameters and lengths of predetermined colonic segments (lengths of rectosigmoid and descending colon; diameters of rectum, sigmoid, descending colon, transverse colon and ascending colon) in relation to the L2 vertebral body width. We included 119 children (median age 2.0 years, range 0-5 years, 68% boys). Colonic segment length ratios did not change significantly with age, although the differences for the rectosigmoid/L2 ratio were borderline significant (P = 0.05). The ratios that involved the rectal and ascending colon diameters increased significantly with age, while diameter ratios involving the other colonic segments did not. Differences by gender and race were not significant. These data can be used for reference purposes in young children undergoing contrast studies of the colon.

  3. Bone tunnel diameter measured with CT after anterior cruciate ligament reconstruction using double-bundle auto-hamstring tendors: Clinical implications

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Soo Jeong; Yoon, Young Cheol; Bae, So Young; Wang, Joon Ho [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2015-12-15

    To evaluate the correlation between bone tunnel diameter after anterior cruciate ligament (ACL) reconstruction measured by computed tomography (CT) using multiplanar reconstruction (MPR) and stability or clinical scores. Forty-seven patients (41 men and 6 women, mean age: 34 years) who had undergone ACL reconstruction with the double bundle technique using auto-hamstring graft and had subsequently received CT scans immediately after the surgery (T1: range, 1-4 days, mean, 2.5 days) and at a later time (T2: range, 297-644 days, mean, 410.4 days) were enrolled in this study. The diameter of each tunnel (two femoral and two tibial) at both T1 and T2 were independently measured using MPR technique by two radiologists. Stability and clinical scores were evaluated with a KT-2000 arthrometer, International Knee Documentation Committee objective scores, and the Lysholm score. Statistical analysis of the correlation between the diameter at T2 or the interval diameter change ratio ([T2 - T1] / T1) and clinical scores or stability was investigated. The tibial bone tunnels for the anteromedial bundles were significantly widened at T2 compared with T1 (observer 1, 0.578 mm to 0.698 mm, p value of < 0.001; observer 2, 0.581 mm to 0.707 mm, p value of < 0.001). There was no significant correlation between the diameter at T2 and stability or clinical scores and between the interval change ratio ([T2 - T1] / T1) and stability or clinical scores (corrected p values for all were 1.0). Intraobserver agreement for measurements was excellent (> 0.8) for both observers. Interobserver agreement for measurement was excellent (> 0.8) except for the most distal portion of the femoral bone tunnel for anterior medial bundle in immediate postoperative CT, which showed moderate agreement (concordance correlation coefficient = 0.6311).Neither the diameter nor its change ratio during interval follow-up is correlated with stability or clinical scores.

  4. Bone tunnel diameter measured with CT after anterior cruciate ligament reconstruction using double-bundle auto-hamstring tendors: Clinical implications

    International Nuclear Information System (INIS)

    Yoon, Soo Jeong; Yoon, Young Cheol; Bae, So Young; Wang, Joon Ho

    2015-01-01

    To evaluate the correlation between bone tunnel diameter after anterior cruciate ligament (ACL) reconstruction measured by computed tomography (CT) using multiplanar reconstruction (MPR) and stability or clinical scores. Forty-seven patients (41 men and 6 women, mean age: 34 years) who had undergone ACL reconstruction with the double bundle technique using auto-hamstring graft and had subsequently received CT scans immediately after the surgery (T1: range, 1-4 days, mean, 2.5 days) and at a later time (T2: range, 297-644 days, mean, 410.4 days) were enrolled in this study. The diameter of each tunnel (two femoral and two tibial) at both T1 and T2 were independently measured using MPR technique by two radiologists. Stability and clinical scores were evaluated with a KT-2000 arthrometer, International Knee Documentation Committee objective scores, and the Lysholm score. Statistical analysis of the correlation between the diameter at T2 or the interval diameter change ratio ([T2 - T1] / T1) and clinical scores or stability was investigated. The tibial bone tunnels for the anteromedial bundles were significantly widened at T2 compared with T1 (observer 1, 0.578 mm to 0.698 mm, p value of < 0.001; observer 2, 0.581 mm to 0.707 mm, p value of < 0.001). There was no significant correlation between the diameter at T2 and stability or clinical scores and between the interval change ratio ([T2 - T1] / T1) and stability or clinical scores (corrected p values for all were 1.0). Intraobserver agreement for measurements was excellent (> 0.8) for both observers. Interobserver agreement for measurement was excellent (> 0.8) except for the most distal portion of the femoral bone tunnel for anterior medial bundle in immediate postoperative CT, which showed moderate agreement (concordance correlation coefficient = 0.6311).Neither the diameter nor its change ratio during interval follow-up is correlated with stability or clinical scores

  5. Diameter-tailored telecom-band luminescence in InP/InAs heterostructure nanowires grown on InP (111)B substrate with continuously-modulated diameter from microscale to nanoscale

    Science.gov (United States)

    Zhang, Guoqiang; Tateno, Kouta; Sogawa, Tetsuomi; Gotoh, Hideki

    2018-04-01

    We report diameter-tailored luminescence in telecom band of InP/InAs multi-heterostructure nanowires with continuously-modulated diameter from microscale to nanoscale. By using the self-catalyzed vapor-solid-liquid approach, we tune the indium particle size, and consequently the InP/InAs nanowire diameter, during growth by modulating the flow rate of the indium source material. This technique allows a high degree of continuous tuning in a wide scale from microscale to nanoscale. Hence it offers an original way to bridge the gap between microscale-featured photolithographic and nanoscale-featured nanolithographic processes and to incorporate InAs quantum disks with tunable diameters into a single InP/InAs quantum heterostructure nanowire. We realized site-defined nanowires with nanoscale diameters initiated from site-defined microscale-diameter particles made with a conventional photolithographic process. The luminescence wavelength from InAs quantum disks is directly connected to the nanowire diameter, by which the strain in the InAs quantum disks is tailored. This work provides new opportunities in the fabrication and design of nanowire devices that extends beyond what is achievable with the current technologies and enables the nanowire shape to be engineered thus offering the potential to broaden the application range of nanowire devices.

  6. Characterization of the frictional losses and heat transfer of oscillatory viscous flow through wire-mesh regenerators

    Directory of Open Access Journals (Sweden)

    A.A. Boroujerdi

    2015-12-01

    Full Text Available In this paper, new relations for calculating heat transfer and pressure drop characteristics of oscillatory flow through wire-mesh screen regenerator such as Darcy permeability, Forchheimer’s inertial coefficient, and heat transfer area per unit volume, as a function of the wire diameter are presented. According to the derived relations, thinner wires have higher pressure drop and higher heat transfer rate. The relations are applicable for all regenerative cryocoolers. Embedding the new relations into a numerical model, three Stirling-type orifice pulse tube cryocoolers with three regenerators different in length and diameter but same volume in a variety of wire diameters, have been modeled. The results achieved by the model reveal that the local heat transfer coefficient decreases with increase of the wire diameter and the length-to-diameter ratio. In addition, it was shown that the mean absolute gas–solid wire temperature difference is a linear function of wire diameter in the range investigated. The results show that for larger length-to-diameter ratios, Forchheimer’s effect will dominate frictional losses, and the variations of the frictional losses are proportional to the inverse of the wire diameter. Wire diameter has been optimized to maximize the coefficient of performance of the cryocooler. Shorter regenerators have thinner optimum wires.

  7. Population structure of Salmonella investigated by amplified fragment length polymorphism

    DEFF Research Database (Denmark)

    Torpdahl, M.; Ahrens, Peter

    2004-01-01

    Aims: This study was undertaken to investigate the usefulness of amplified fragment length polymorphism (AFLP) in determining the population structure of Salmonella. Methods and Results: A total of 89 strains were subjected to AFLP analysis using the enzymes BglII and BspDI, a combination...... that is novel in Salmonella. Both species S. bongori and S. enterica and all subsp. of S. enterica were represented with emphasis on S. enterica subsp. enterica using a local strain collection and strains from the Salmonella Reference Collection B (SARB). The amplified fragments were used in a band...

  8. Validation of digit-length ratio (2D:4D) assessments on the basis of DXA-derived hand scans

    International Nuclear Information System (INIS)

    Romann, Michael; Fuchslocher, Jörg

    2015-01-01

    The second-to-fourth digit-length ratio (2D:4D) may be a correlate of prenatal sex steroids, and it has been linked to sporting prowess. The aim of the study was to validate dual-energy X-ray-absorptiometry (DXA) as a technique to assess 2D:4D in soccer players under 15 years of age (U-15). Paired X-ray and DXA scans of the left hands of 63 male U-15 elite soccer players (age: 14.0 ± 0.3 years) were performed, and 2D:4D was then compared between the two techniques. The 2D:4D measurements were performed twice by two blinded raters. Intrarater and interrater reliability, as well as agreement between the X-ray and the DXA assessments, were tested. Intrarater reliabilities of both raters using X-ray with intraclass correlation coefficients (ICCs) of 0.97 and 0.90 were excellent. Using DXA, the ICCs were 0.90 and 0.91 thus also showing excellent reliability. Interrater reliabilities were excellent using both the X-ray (ICC of 0.94) and the DXA (ICC of 0.90), assessments respectively. Bland-Altman plots demonstrated that the 2D:4D ratios of the two raters did not differ significantly between the X-ray and the DXA assessments. The standard errors of estimate were 0.01 for both techniques. The 95% limits of agreement of ±0.018 (±2.0%) and ±0.023 (±2.6%), respectively, were within the acceptable tolerance of 5%, and showed very good agreement. DXA offered a replicable technique for assessing 2D:4D in youth soccer players. Therefore, the DXA technique seems to be an alternative method for evaluating 2D:4D in youth sports

  9. Likelihood-ratio-based biometric verification

    NARCIS (Netherlands)

    Bazen, A.M.; Veldhuis, Raymond N.J.

    2002-01-01

    This paper presents results on optimal similarity measures for biometric verification based on fixed-length feature vectors. First, we show that the verification of a single user is equivalent to the detection problem, which implies that for single-user verification the likelihood ratio is optimal.

  10. Likelihood Ratio-Based Biometric Verification

    NARCIS (Netherlands)

    Bazen, A.M.; Veldhuis, Raymond N.J.

    The paper presents results on optimal similarity measures for biometric verification based on fixed-length feature vectors. First, we show that the verification of a single user is equivalent to the detection problem, which implies that, for single-user verification, the likelihood ratio is optimal.

  11. Turbulent jet diffusion flame length evolution with cross flows in a sub-pressure atmosphere

    International Nuclear Information System (INIS)

    Wang, Qiang; Hu, Longhua; Zhang, Xiaozheng; Zhang, Xiaolei; Lu, Shouxiang; Ding, Hang

    2015-01-01

    Highlights: • Quantifying turbulent jet diffusion flame length with cross flows. • Unique data revealed for a sub-atmospheric pressure. • Non-dimensional global correlation proposed for flame trajectory-line length. - Abstract: This paper investigates the evolution characteristics of turbulent jet diffusion flame (flame trajectory-line length, flame height in vertical jet direction) with increasing cross flows in a sub-pressure (64 kPa) atmosphere. The combined effect of cross flow and a special sub-pressure atmosphere condition is revealed, where no data is available in the literatures. Experiments are carried out with a wind tunnel built specially in Lhasa city (altitude: 3650 m; pressure: 64 kPa) and in Hefei city (altitude: 50 m; pressure: 100 kPa), using nozzles with diameter of 3 mm, 4 mm and 5 mm and propane as fuel. It is found that, as cross flow air speed increases from zero, the flame trajectory-line length firstly decreases and then becomes almost stable (for relative small nozzle, 3 mm in this study) or increases (for relative large nozzle, 4 mm and 5 mm in this study) beyond a transitional critical cross flow air speed in normal pressure, however decreases monotonically until being blown-out in the sub-pressure atmosphere. The flame height in jet direction decreases monotonically with cross air flow speed and then reaches a steady value in both pressures. For the transitional state of flame trajectory-line length with increasing cross air flow speed, the corresponding critical cross flow air speed is found to be proportional to the fuel jet velocity, meanwhile independent of nozzle diameter. Correlation models are proposed for the flame height in jet direction and the flame trajectory-line length for both ambient pressures, which are shown to be in good agreement with the experimental results.

  12. Increasing the transformer ratio at the Argonne wakefield accelerator

    International Nuclear Information System (INIS)

    Power, J.G.; Conde, M.; Liu, W.; Yusof, Z.; Gai, W.; Jing, C.; Kanareykin, A.

    2011-01-01

    The transformer ratio is defined as the ratio of the maximum energy gain of the witness bunch to the maximum energy loss experienced by the drive bunch (or a bunch within a multidrive bunch train). This plays an important role in the collinear wakefield acceleration scheme. A high transformer ratio is desirable since it leads to a higher overall efficiency under similar conditions (e.g. the same beam loading, the same structure, etc.). One technique to enhance the transformer ratio beyond the ordinary limit of 2 is to use a ramped bunch train. The first experimental demonstration observed a transformer ratio only marginally above 2 due to the mismatch between the drive microbunch length and the frequency of the accelerating structure (C. Jing, A. Kanareykin, J. Power, M. Conde, Z. Yusof, P. Schoessow, and W. Gai, Phys. Rev. Lett. 98, 144801 (2007)). Recently, we revisited this experiment with an optimized microbunch length using a UV laser stacking technique at the Argonne Wakefield Accelerator facility and measured a transformer ratio of 3.4. Measurements and data analysis from these experiments are presented in detail.

  13. Isotachophoresis system having larger-diameter channels flowing into channels with reduced diameter and with selectable counter-flow

    Energy Technology Data Exchange (ETDEWEB)

    Mariella, Jr., Raymond P.

    2018-03-06

    An isotachophoresis system for separating a sample containing particles into discrete packets including a flow channel, the flow channel having a large diameter section and a small diameter section; a negative electrode operably connected to the flow channel; a positive electrode operably connected to the flow channel; a leading carrier fluid in the flow channel; a trailing carrier fluid in the flow channel; and a control for separating the particles in the sample into discrete packets using the leading carrier fluid, the trailing carrier fluid, the large diameter section, and the small diameter section.

  14. The expression of the skeletal muscle force-length relationship in vivo: a simulation study.

    Science.gov (United States)

    Winter, Samantha L; Challis, John H

    2010-02-21

    The force-length relationship is one of the most important mechanical characteristics of skeletal muscle in humans and animals. For a physiologically realistic joint range of motion and therefore range of muscle fibre lengths only part of the force-length curve may be used in vivo, i.e. only a section of the force-length curve is expressed. A generalised model of a mono-articular muscle-tendon complex was used to examine the effect of various muscle architecture parameters on the expressed section of the force-length relationship for a 90 degrees joint range of motion. The parameters investigated were: the ratio of tendon resting length to muscle fibre optimum length (L(TR):L(F.OPT)) (varied from 0.5 to 11.5), the ratio of muscle fibre optimum length to average moment arm (L(F.OPT):r) (varied from 0.5 to 5), the normalised tendon strain at maximum isometric force (c) (varied from 0 to 0.08), the muscle fibre pennation angle (theta) (varied from 0 degrees to 45 degrees) and the joint angle at which the optimum muscle fibre length occurred (phi). The range of values chosen for each parameter was based on values reported in the literature for five human mono-articular muscles with different functional roles. The ratios L(TR):L(F.OPT) and L(F.OPT):r were important in determining the amount of variability in the expressed section of the force-length relationship. The modelled muscle operated over only one limb at intermediate values of these two ratios (L(TR):L(F.OPT)=5; L(F.OPT):r=3), whether this was the ascending or descending limb was determined by the precise values of the other parameters. It was concluded that inter-individual variability in the expressed section of the force-length relationship is possible, particularly for muscles with intermediate values of L(TR):L(F.OPT) and L(F.OPT):r such as the brachialis and vastus lateralis. Understanding the potential for inter-individual variability in the expressed section is important when using muscle models to

  15. Time, number and length: similarities and differences in discrimination in adults and children.

    Science.gov (United States)

    Droit-Volet, Sylvie; Clément, Angélique; Fayol, Michel

    2008-01-01

    The aim of this study was to focus on similarities in the discrimination of three different quantities--time, number, and line length--using a bisection task involving children aged 5 and 8 years and adults, when number and length were presented nonsequentially (Experiment 1) and sequentially (Experiment 2). In the nonsequential condition, for all age groups, although to a greater extent in the younger children, the psychophysical functions were flatter, and the Weber ratio higher for time than for number and length. Number and length yielded similar psychophysical functions. Thus, sensitivity to time was lower than that to the other quantities, whether continuous or not. However, when number and length were presented sequentially (Experiment 2), the differences in discrimination performance between time, number, and length disappeared. Furthermore, the Weber ratio values as well as the bisection points for all quantities presented sequentially appeared to be close to that found for duration in the nonsequential condition. The results are discussed within the framework of recent theories suggesting a common mechanism for all analogical quantities.

  16. Mechanisms involved in the hydrothermal growth of ultra-thin and high aspect ratio ZnO nanowires

    Science.gov (United States)

    Demes, Thomas; Ternon, Céline; Morisot, Fanny; Riassetto, David; Legallais, Maxime; Roussel, Hervé; Langlet, Michel

    2017-07-01

    Hydrothermal synthesis of ZnO nanowires (NWs) with tailored dimensions, notably high aspect ratios (AR) and small diameters, is a major concern for a wide range of applications and still represents a challenging and recurring issue. In this work, an additive-free and reproducible hydrothermal procedure has been developed to grow ultra-thin and high AR ZnO NWs on sol-gel deposited ZnO seed layers. Controlling the substrate temperature and using a low reagent concentration (1 mM) has been found to be essential for obtaining such NWs. We show that the NW diameter remains constant at about 20-25 nm with growth time contrary to the NW length that can be selectively increased leading to NWs with ARs up to 400. On the basis of investigated experimental conditions along with thermodynamic and kinetic considerations, a ZnO NW growth mechanism has been developed which involves the formation and growth of nuclei followed by NW growth when the nuclei reach a critical size of about 20-25 nm. The low reagent concentration inhibits NW lateral growth leading to ultra-thin and high AR NWs. These NWs have been assembled into electrically conductive ZnO nanowire networks, which opens attractive perspectives toward the development of highly sensitive low-cost gas- or bio-sensors.

  17. Three-phase boundary length in solid-oxide fuel cells: A mathematical model

    Energy Technology Data Exchange (ETDEWEB)

    Janardhanan, Vinod M. [Institutefor Chemical Technology and Polymer Chemistry, University of Karlsruhe (TH), Kaiserstr. 12, D-76128 Karlsruhe (Germany); Heuveline, Vincent; Deutschmann, Olaf [Institute for Applied and Numerical Mathematics, University of Karlsruhe (TH), Kaiserstr. 12, D-76128 Karlsruhe (Germany)

    2008-03-15

    A mathematical model to calculate the volume specific three-phase boundary length in the porous composite electrodes of solid-oxide fuel cell is presented. The model is exclusively based on geometrical considerations accounting for porosity, particle diameter, particle size distribution, and solids phase distribution. Results are presented for uniform particle size distribution as well as for non-uniform particle size distribution. (author)

  18. Three-phase boundary length in solid-oxide fuel cells: A mathematical model

    Science.gov (United States)

    Janardhanan, Vinod M.; Heuveline, Vincent; Deutschmann, Olaf

    A mathematical model to calculate the volume specific three-phase boundary length in the porous composite electrodes of solid-oxide fuel cell is presented. The model is exclusively based on geometrical considerations accounting for porosity, particle diameter, particle size distribution, and solids phase distribution. Results are presented for uniform particle size distribution as well as for non-uniform particle size distribution.

  19. Two independent measurements of Debye lengths in doped nonpolar liquids.

    Science.gov (United States)

    Prieve, D C; Hoggard, J D; Fu, R; Sides, P J; Bethea, R

    2008-02-19

    Electric current measurements were performed between 2.5 cm x 7.5 cm parallel-plate electrodes separated by 1.2 mm of heptane doped with 0-15% w/w poly(isobutylene succinimide) (PIBS) having a molecular weight of about 1700. The rapid (microsecond) initial charging of the capacitor can be used to infer the dielectric constant of the solution. The much slower decay of current arising from the polarization of electrodes depends on the differential capacitance of the diffuse clouds of charge carriers accumulating next to each electrode and on the ohmic resistance of the fluid. Using the Gouy-Chapman model for the differential capacitance, Debye lengths of 80-600 nm were deduced that decrease with increasing concentration of PIBS. Values of the Debye lengths were confirmed by performing independent measurements of double-layer repulsion between a 6 microm polystyrene (PS) latex sphere and a PS-coated glass plate using total internal reflection microscopy in the same solutions. The charge carriers appear to be inverted PIBS micelles having apparent Stokes diameters of 20-40 nm. Dynamic light scattering reveals a broad distribution of sizes having an intensity-averaged diameter of 15 nm. This smaller size might arise (1) from overestimating the electrophoretic mobility of micelles by treating them as point charges or (2) because charged micelles are larger on average than uncharged micelles. When Faradaic reactions and zeta potentials on the electrodes can be neglected, such current versus time experiments yield values for the Debye length and ionic strength with less effort than force measurements. To obtain the concentration of charge carriers from measurements of conductivity, the mobility of the charge carriers must be known.

  20. Preoperative lymphocyte-to-monocyte ratio represents a superior predictor compared with neutrophil-to-lymphocyte and platelet-to-lymphocyte ratios for colorectal liver-only metastases survival

    Directory of Open Access Journals (Sweden)

    Peng JH

    2017-07-01

    Full Text Available Jianhong Peng,1,* Hui Li,2,* Qingjian Ou,1,* Junzhong Lin,1 Xiaojun Wu,1 Zhenhai Lu,1 Yunfei Yuan,1 Desen Wan,1 Yujing Fang,1 Zhizhong Pan1 1Department of Colorectal Surgery, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, People’s Republic of China; 2Zhongshan School of Medicine, Sun Yat-sen University, Guangzhou, People’s Republic of China *These authors contributed equally to this work Abstract: Systemic inflammation was recognized as an essential factor contributing to the development of malignancies. This study aimed to investigate the prognostic value of preoperative lymphocyte-to-monocyte ratio (LMR, neutrophil-to-lymphocyte ratio (NLR, and platelet-to-lymphocyte ratio (PLR in patients with colorectal liver-only metastases (CLOM undergoing hepatectomy. We retrospectively enrolled 150 consecutive patients with CLOM between 2000 and 2012. The optimal cutoff values of continuous LMR, NLR, and PLR were determined using the receiver operating characteristic curve analysis. Recurrence-free survival (RFS and overall survival (OS related to the LMR, NLR, and PLR were analyzed using both Kaplan–Meier and multivariate Cox regression methods. Elevated LMR (≥2.82 and lower NLR (<4.63 were significantly associated with better RFS and OS in patients with CLOM after hepatectomy, instead of lower PLR (<150.17. Multivariate Cox analysis identified elevated LMR as the only independent inflammatory factor for better RFS (hazard ratio, 0.591; 95% CI, 0.32–0.844; P=0.008 and OS (hazard ratio, 0.426; 95% CI, 0.254–0.716; P=0.001. In the subgroup analysis, elevated LMR was a significant favorable factor in both 5-year RFS and OS of patients with male gender, lymph node metastases, colon cancer, liver tumor with the largest diameter <5 cm, preoperative carcinoembryonic antigen level <200 ng/mL, negative hepatitis B virus infection, non

  1. Diameter-dependent coloration of silver nanowires

    International Nuclear Information System (INIS)

    Stewart, Mindy S; Qiu Chao; Jiang Chaoyang; Kattumenu, Ramesh; Singamaneni, Srikanth

    2011-01-01

    Silver nanowires were synthesized with a green method and characterized with microscopic and diffractometric methods. The correlation between the colors of the nanowires deposited on a solid substrate and their diameters was explored. Silver nanowires that appear similar in color in the optical micrographs have very similar diameters as determined by atomic force microscopy. We have summarized the diameter-dependent coloration for these silver nanowires. An optical interference model was applied to explain such correlation. In addition, microreflectance spectra were obtained from individual nanowires and the observed spectra can be explained with the optical interference theory. This work provides a cheap, quick and simple screening method for studying the diameter distribution of silver nanowires, as well as the diameter variations of individual silver nanowires, without complicated sample preparation.

  2. Pollutant Dispersion in Boundary Layers Exposed to Rural-to-Urban Transitions: Varying the Spanwise Length Scale of the Roughness

    Science.gov (United States)

    Tomas, J. M.; Eisma, H. E.; Pourquie, M. J. B. M.; Elsinga, G. E.; Jonker, H. J. J.; Westerweel, J.

    2017-05-01

    Both large-eddy simulations (LES) and water-tunnel experiments, using simultaneous stereoscopic particle image velocimetry and laser-induced fluorescence, have been used to investigate pollutant dispersion mechanisms in regions where the surface changes from rural to urban roughness. The urban roughness was characterized by an array of rectangular obstacles in an in-line arrangement. The streamwise length scale of the roughness was kept constant, while the spanwise length scale was varied by varying the obstacle aspect ratio l / h between 1 and 8, where l is the spanwise dimension of the obstacles and h is the height of the obstacles. Additionally, the case of two-dimensional roughness (riblets) was considered in LES. A smooth-wall turbulent boundary layer of depth 10 h was used as the approaching flow, and a line source of passive tracer was placed 2 h upstream of the urban canopy. The experimental and numerical results show good agreement, while minor discrepancies are readily explained. It is found that for l/h=2 the drag induced by the urban canopy is largest of all considered cases, and is caused by a large-scale secondary flow. In addition, due to the roughness transition the vertical advective pollutant flux is the main ventilation mechanism in the first three streets. Furthermore, by means of linear stochastic estimation the mean flow structure is identified that is responsible for street-canyon ventilation for the sixth street and onwards. Moreover, it is shown that the vertical length scale of this structure increases with increasing aspect ratio of the obstacles in the canopy, while the streamwise length scale does not show a similar trend.

  3. Note: Strain sensitivity comparison between fiber Bragg gratings inscribed on 125 and 80 micron cladding diameter fibers, case study on the solidification monitoring of a photo-curable resin

    Energy Technology Data Exchange (ETDEWEB)

    Maccioni, E. [Dipartimento di Fisica, Università degli Studi di Pisa, Largo B. Pontecorvo 3, 56127 Pisa (Italy); Istituto Nazionale di Fisica Nucleare (INFN) sez. di Pisa, Largo B. Pontecorvo 3, 56127 Pisa (Italy); Morganti, M. [Istituto Nazionale di Fisica Nucleare (INFN) sez. di Pisa, Largo B. Pontecorvo 3, 56127 Pisa (Italy); Accademia Militare di Livorno, Viale Italia 72, 57100 Livorno (Italy); Brandi, F., E-mail: fernando.brandi@ino.it [Nanophysics Department, Istituto Italiano di Tecnologia, Via Morego 30, 16163 Genova (Italy); Istituto Nazionale di Ottica (INO), Consiglio Nazionale delle Ricerche (CNR), Via G. Moruzzi 1, 56124 Pisa (Italy)

    2015-02-15

    The influence of fiber Bragg grating diameter when measuring strain is investigated and quantified. Two fiber Bragg gratings with bare cladding diameter of 125 μm and 80 μm are produced by excimer laser irradiation through a phase mask, and are used to simultaneously monitor the Bragg wavelength shift due to the strain produced by the solidification of a photo-curable resin during light exposure. It is found that the ratio of the measured strains in the two fiber Bragg gratings is close to the inverse ratio of the fiber’s cladding diameter. These results represent a direct simultaneous comparison between 125 μm and 80 μm diameter fiber Bragg grating strain sensors, and demonstrate the feasibility of strain measurements in photo-curable resins using bare 80 μm cladding diameter fiber Bragg gratings with an increased sensitivity and spatial resolution compared with standard 125 μm diameter fiber Bragg gratings.

  4. Weight-length Relationships, Gonadosomatic Indeces, Sex Ratios and Relative Weight of the Omani-Indian Oil sardine, Sardinella longiceps (Valenciennes1847) from Al-Seeb Area; Sultanate of Oman

    OpenAIRE

    Al-Jufaili Saud

    2011-01-01

    This study presents the weight-length relationship and spawning period of the Omani Indian Oil sardine Sardinella longiceps (Valenciennes 1847) which inhabits the near shore zone along the Omani coast. A total of 1744 specimens were collected between January 1997 to February 1998 from Al-Seeb; a suburban area situated by the sea in Muscat, Oman. Samples were obtained on a monthly basis from beach seine and gillnet catches. The female to male sex ratio was obtained to be 0.6. The monthly varia...

  5. Interfacial area transport of bubbly flow in a small diameter pipe

    International Nuclear Information System (INIS)

    Hibiki, Takashi; Takamasa, Tomoji; Ishii, Mamoru

    2001-01-01

    In relation to the development of the interfacial area transport equation, this study focused on modeling of the interfacial area transport mechanism of vertical adiabatic air-water bubbly flows in a relatively small diameter pipe where the bubble size-to-pipe diameter ratio was relatively high and the radial motion of bubbles was restricted by the presence of the pipe wall. The sink term of the interfacial area concentration was modeled by considering wake entrainment as a possible bubble coalescence mechanism, whereas the source term was neglected by assuming negligibly small bubble breakup for low liquid velocity conditions based on visual observation. One-dimensional interfacial area transport equation with the derived sink term was evaluated by using five datasets of vertical adiabatic air-water bubbly flows measured in a 9.0 mm-diameter pipe (superficial gas velocity: 0.013-0.052 m/s, superficial liquid velocity: 0.58-1.0 m/s). The modeled interfacial area transport equation could reproduce the proper trend of the axial interfacial area transport and predict the measured interfacial area concentrations within an average relative deviation of ±11.1%. It was recognized that the present model would be promising for predicting the interfacial area transport of the examined bubbly flows. (author)

  6. Burnout heat flux in natural flow boiling

    International Nuclear Information System (INIS)

    Helal, M.M.; Darwish, M.A.; Mahmoud, S.I.

    1978-01-01

    Twenty runs of experiments were conducted to determine the critical heat flux for natural flow boiling with water flowing upwards through annuli of centrally heated stainless steel tube. The test section has concentric heated tube of 14mm diameter and heated lengthes of 15 and 25 cm. The outside surface of the annulus was formed by various glass tubes of 17.25, 20 and 25.9mm diameter. System pressure is atmospheric. Inlet subcooling varied from 18 to 5 0 C. Obtained critical heat flux varied from 24.46 to 62.9 watts/cm 2 . A number of parameters having dominant influence on the critical heat flux and hydrodynamic instability (flow and pressure oscillations) preceeding the burnout have been studied. These parameters are mass flow rate, mass velocity, throttling, channel geometry (diameters ratio, length to diameter ratio, and test section length), and inlet subcooling. Flow regimes before and at the moments of burnout were observed, discussed, and compared with the existing physical model of burnout

  7. Is length an appropriate estimator to characterize pulmonary alveolar capillaries? A critical evaluation in the human lung

    DEFF Research Database (Denmark)

    Mühlfeld, Christian; Weibel, Ewald R.; Hahn, Ute

    2010-01-01

    Stereological estimations of total capillary length have been used to characterize changes in the alveolar capillary network (ACN) during developmental processes or pathophysiological conditions. Here, we analyzed whether length estimations are appropriate to describe the 3D nature of the ACN. Semi...... resulted in a mean of 2,746 km (SD: 722 km). Because of the geometry of the ACN both approaches carry an unpredictable bias. The bias incurred by the design-based approach is proportional to the ratio between radius and length of the capillary segments in the ACN, the number of branching points...... and the winding of the capillaries. The model-based approach is biased because of the real noncylindrical shape of capillaries and the network structure. In conclusion, the estimation of the total length of capillaries in the ACN cannot be recommended as the geometry of the ACN does not fulfill the requirements...

  8. Stochastic model of radon daughter deposition and clearance in human bronchial airways

    International Nuclear Information System (INIS)

    Hofmann, W.

    1996-01-01

    Morphometric measurements of human airway casts have repealed that the human bronchial tree is an asymmetrically dividing network, exhibiting individual variations of airway dimensions within a given airway generation Thus, a statistical correlation exists between the linear dimensions of a given parent airway and those of the asymmetrically dividing daughter branches. This statistical relationship, however, is constrained by correlations among various geometrical parameters. i.e., the human lung is not a fully stochastic system. From a statistical analysis of these morphometric data, the following geometrical parameters could be obtained for each airway generation or bifurcation: (i) probability distributions for diameters and lengths, ratios of parent cross section to the combined cross section of both daughters, ratios of major to minor daughter diameters, and branching angles for major and minor branches; (ii) correlations of diameters and lengths; and (iii) the probability of terminating the bronchial region as a function of both diameter and generation number. Since the original lung morphometry refers to total lung capacity, airway diameters and lengths were scaled down to functional residual capacity. (author)

  9. Selection of LWR cycle length and fuel reload fraction

    International Nuclear Information System (INIS)

    Driscoll, M.J.; Handwerk, C.S.; McMahon, M.V.

    1997-01-01

    The continuing evolution of fuel having ever higher burnup capability and the increased emphasis on high plant capacity factor to keep nuclear power cost-competitive, motivates re-examination of some basic fuel management strategies. Specifically, what are the economic optimum goals for the fraction of core to be refueled, 1/n, and the length of the intra-refueling cycle, T c . The authors present a simple model to study these questions. They conclude that unless substantial improvements in technology are forthcoming, or economic circumstances change significantly, departure from 2- to 4-batch management, or longer than 2- to 3-year cycles in LWRs is not supported by their analysis

  10. Influence of skew rays on the sensitivity and signal-to-noise ratio of a fiber-optic surface-plasmon-resonance sensor: a theoretical study

    International Nuclear Information System (INIS)

    Dwivedi, Yogendra S.; Sharma, Anuj K.; Gupta, Banshi D.

    2007-01-01

    We have theoretically analyzed the influence of skew rays on the performance of a fiber-optic sensor based on surface plasmon resonance. The performance of the sensor has been evaluated in terms of its sensitivity and signal-to-noise ratio (SNR). The theoretical model for skewness dependence includes the material dispersion in fiber cores and metal layers, simultaneous excitation of skew rays, and meridional rays in the fiber core along with all guided rays launching from a collimated light source. The effect of skew rays on the SNR and the sensitivity of the sensor with two different metals has been compared. The same comparison is carried out for the different values of design parameters such as numerical aperture, fiber core diameter, and the length of the surface-plasmon-resonance (SPR)active sensing region. This detailed analysis for the effect of skewness on the SNR and the sensitivity of the sensor leads us to achieve the best possible performance from a fiber-optic SPR sensor against the skewness in the optical fiber

  11. Usefulness of Tricuspid Annular Diameter to Predict Late Right Sided Heart Failure in Patients With Left Ventricular Assist Device.

    Science.gov (United States)

    Nakanishi, Koki; Homma, Shunichi; Han, Jiho; Takayama, Hiroo; Colombo, Paolo C; Yuzefpolskaya, Melana; Garan, Arthur R; Farr, Maryjane A; Kurlansky, Paul; Di Tullio, Marco R; Naka, Yoshifumi; Takeda, Koji

    2018-07-01

    Although late-onset right-sided heart failure is recognized as a clinical problem in the treatment of patients with left ventricular assist devices (LVADs), the mechanism and predictors are unknown. Tricuspid valve (TV) deformation leads to the restriction of the leaflet motion and decreased coaptation, resulting in a functional tricuspid regurgitation that may act as a surrogate marker of late right-sided heart failure. This study aimed to investigate the association of preoperative TV deformation (annulus dilatation and leaflet tethering) with late right-sided heart failure development after continuous-flow LVAD implantation. The study cohort consisted of 274 patients who underwent 2-dimensional echocardiography before LVAD implantation. TV annulus diameter and tethering distance were measured in an apical 4-chamber view. Late right-sided heart failure was defined as right-sided heart failure requiring readmission and medical and/or surgical treatment after initial LVAD implantation. During a mean follow-up of 25.1 ± 19.0 months after LVAD implantation, late right-sided heart failure occurred in 33 patients (12.0%). Multivariate Cox proportional hazard analysis demonstrated that TV annulus diameter (hazard ratio 1.221 per 1 mm, p right-sided heart failure development, whereas leaflet tethering distance was not. The best cut-off value of the TV annular diameter was 41 mm (area under the curve 0.787). Kaplan-Meier analysis showed that patients with dilated TV annulus (TV annular diameter ≥41 mm) exhibited a significantly higher late right-sided heart failure occurrence than those without TV annular enlargement (log-rank p right-sided heart failure after LVAD implantation. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Study of the Inception Length of Flow over Stepped Spillway Models ...

    African Journals Online (AJOL)

    The results showed that the inception (development) length increases as the unit discharge increases and it decreases with an increase in both stepped roughness height and chute angle. The ratio of the development length, in this study, to that of Bauer's was found to be 4:5. Finally, SMM-5 produced the least velocity of ...

  13. Investigation of entrance length in circular and noncircular conduits by computational fluid dynamics simulation

    Directory of Open Access Journals (Sweden)

    Pimpun Tongpun

    2014-08-01

    Full Text Available This study estimated entrance length of circular and noncircular conduits, including circle, triangle, square and hexagon cross-sectional conduit, by using computational fluid dynamics (CFD. For simulation condition, the length of noncircular conduit was 10 m and the hydraulic diameter was 0.2 m. The laminar flow with Reynolds number of 500 and turbulent flow with Reynolds number of 50,000 were applied to investigate water flow in conduits. The governing equations were solved iteratively by using ANSYS FLUENT 14.0. For turbulent flow simulation, standard k-epsilon and RNG k-epsilon model were employed to simulate turbulence. The preliminary results were validated by comparison with theoretical data. At first, grid independency was evaluated to optimize the model. Norm* was employed to investigate the entrance length, which is related to velocity. The simulated results revealed that the entrance length for laminar flow was longer than turbulent flow.

  14. All-optical, thermo-optical path length modulation based on the vanadium-doped fibers.

    Science.gov (United States)

    Matjasec, Ziga; Campelj, Stanislav; Donlagic, Denis

    2013-05-20

    This paper presents an all-fiber, fully-optically controlled, optical-path length modulator based on highly absorbing optical fiber. The modulator utilizes a high-power 980 nm pump diode and a short section of vanadium-co-doped single mode fiber that is heated through absorption and a non-radiative relaxation process. The achievable path length modulation range primarily depends on the pump's power and the convective heat-transfer coefficient of the surrounding gas, while the time response primarily depends on the heated fiber's diameter. An absolute optical length change in excess of 500 µm and a time-constant as short as 11 ms, were demonstrated experimentally. The all-fiber design allows for an electrically-passive and remote operation of the modulator. The presented modulator could find use within various fiber-optics systems that require optical (remote) path length control or modulation.

  15. Gradient pre-emphasis to counteract first-order concomitant fields on asymmetric MRI gradient systems.

    Science.gov (United States)

    Tao, Shengzhen; Weavers, Paul T; Trzasko, Joshua D; Shu, Yunhong; Huston, John; Lee, Seung-Kyun; Frigo, Louis M; Bernstein, Matt A

    2017-06-01

    To develop a gradient pre-emphasis scheme that prospectively counteracts the effects of the first-order concomitant fields for any arbitrary gradient waveform played on asymmetric gradient systems, and to demonstrate the effectiveness of this approach using a real-time implementation on a compact gradient system. After reviewing the first-order concomitant fields that are present on asymmetric gradients, we developed a generalized gradient pre-emphasis model assuming arbitrary gradient waveforms to counteract their effects. A numerically straightforward, easily implemented approximate solution to this pre-emphasis problem was derived that was compatible with the current hardware infrastructure of conventional MRI scanners for eddy current compensation. The proposed method was implemented on the gradient driver subsystem, and its real-time use was tested using a series of phantom and in vivo data acquired from two-dimensional Cartesian phase-difference, echo-planar imaging, and spiral acquisitions. The phantom and in vivo results demonstrated that unless accounted for, first-order concomitant fields introduce considerable phase estimation error into the measured data and result in images with spatially dependent blurring/distortion. The resulting artifacts were effectively prevented using the proposed gradient pre-emphasis. We have developed an efficient and effective gradient pre-emphasis framework to counteract the effects of first-order concomitant fields of asymmetric gradient systems. Magn Reson Med 77:2250-2262, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  16. Wiener Index, Diameter, and Stretch Factor of a Weighted Planar Graph in Subquadratic Time

    DEFF Research Database (Denmark)

    Wulff-Nilsen, Christian

    over all pairs of distinct vertices of the ratio between the graph distance and the Euclidean distance between the two vertices). More specifically, we show that the Wiener index and diameter can be found in O(n^2*(log log n)^4/log n) worst-case time and that the stretch factor can be found in O(n^2......We solve three open problems: the existence of subquadratic time algorithms for computing the Wiener index (sum of APSP distances) and the diameter (maximum distance between any vertex pair) of a planar graph with non-negative edge weights and the stretch factor of a plane geometric graph (maximum...

  17. Leukocyte Telomere Length and Cognitive Function in Older Adults

    Directory of Open Access Journals (Sweden)

    Emily Frith

    2018-04-01

    Full Text Available We evaluated the specific association between leukocyte telomere length and cognitive function among a national sample of the broader U.S. older adult population. Data from the 1999-2002 National Health and Nutrition Examination Survey (NHANES were used to identify 1,722 adults, between 60-85 years, with complete data on selected study variables. DNA was extracted from whole blood via the LTL assay, which is administered using quantitative polymerase chain reaction to measure telomere length relative to standard reference DNA (T/S ratio. Average telomere length was recorded, with two to three assays performed to control for individual variability. The DSST (Digit Symbol Substitution Test was used to assess participant executive cognitive functioning tasks of pairing and free recall. Individuals were excluded if they had been diagnosed with coronary artery disease, congestive heart failure, heart attack or stroke at the baseline assessment. Leukocyte telomere length was associated with higher cognitive performance, independent of gender, race-ethnicity, physical activity status, body mass index and other covariates. In this sample, there was a strong association between LTL and cognition; for every 1 T/S ratio increase in LTL, there was a corresponding 9.9 unit increase in the DSST (β = 9.9; 95% CI: 5.6-14.2; P [JCBPR 2018; 7(1.000: 14-18

  18. An in-pipe mobile micromachine using fluid power. A mechanism adaptable to pipe diameters

    International Nuclear Information System (INIS)

    Yoshida, Kazuhiro; Yokota, Shinichi; Takahashi, Ken

    2000-01-01

    To realize micro maintenance robots for small diameter pipes of nuclear reactors and so on, high power in-pipe mobile micromachines have been required. The authors have proposed the bellows microactuator using fluid power and have tried to apply the actuators to in-pipe mobile micromachines. In the previous papers, some inchworm mobile machine prototypes with 25 mm in diameter are fabricated and the traveling performances are experimentally investigated. In this paper, to miniaturize the in-pipe mobile machine and to make it adaptable to pipe diameters, firstly, a simple rubber-tube actuator constrained with a coil-spring is proposed and the static characteristics are investigated. Secondly, a supporting mechanism which utilizes a toggle mechanism and is adaptable to pipe diameters is proposed and the supporting forces are investigated. Finally, an in-pipe mobile micromachine for pipe with 4 - 5 mm in diameter is fabricated and the maximum traveling velocity of 7 mm/s in both ahead and astern movements is experimentally verified. (author)

  19. Optimization study on pin tip diameter of an impact-pin nozzle at high pressure ratio

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, C. Palani; Lee, Kwon Hee [FMTRC, Daejoo Machinery Co. Ltd., Daegu (Korea, Republic of); Park, Tae Choon; Cha, Bong Jun [Engine Components Research Team, Korea Aerospace Research Institute, Daejeon (Korea, Republic of); Kim, Heuy Dong [Dept. of Mechanical Engineering, Andong National University, Andong (Korea, Republic of)

    2016-09-15

    Wet compression system is typically installed in a gas turbine engine to increase the net power output and efficiency. A crucial component of the wet compression system is the nozzle which generates fine water droplets for injection into the compressor. The main objective of present work is to optimize a kind of nozzle called impact-pin spray nozzle and thereby produce better quality droplets. To achieve this, the dynamics occurring in the water jet impinging on the pin tip, the subsequent formation of water sheet, which finally breaks into water droplets, must be studied. In this manuscript, the progress on the numerical studies on impact-pin nozzle are reported. A small computational domain covering the orifice, pin tip and the region where primary atomization occurs is selected for numerical analysis. The governing equations are selected in three dimensional cartesian form and simulations are performed to predict the dynamics of water jet impinging on the pin. Systematic studies were carried out and the results leading to the choice of turbulence model and the effect of pin tip diameter are reported here. Further studies are proposed to show the future directions of the present research work.

  20. Plant/soil concentration ratios for paired field and garden crops, with emphasis on iodine and the role of soil adhesion

    International Nuclear Information System (INIS)

    Sheppard, S.C.; Long, J.M.; Sanipelli, B.

    2010-01-01

    In the effort to predict the risks associated with contaminated soils, considerable reliance is placed on plant/soil concentration ratio (CR) values measured at sites other than the contaminated site. This inevitably results in the need to extrapolate among the many soil and plant types. There are few studies that compare CR among plant types that encompass both field and garden crops. Here, CRs for 40 elements were measured for 25 crops from farm and garden sites chosen so the grain crops were in close proximity to the gardens. Special emphasis was placed on iodine (I) because data for this element are sparse. For many elements, there were consistent trends among CRs for the various crop types, with leafy crops > root crops ≥ fruit crops ∼ seed crops. Exceptions included CR values for As, K, Se and Zn which were highest in the seed crops. The correlation of CRs from one plant type to another was evident only when there was a wide range in soil concentrations. In comparing CRs between crop types, it became apparent that the relationships differed for the rare earth elements (REE), which also had very low CR values. The CRs for root and leafy crops of REE converged to a minimum value. This was attributed to soil adhesion, despite the samples being washed, and the average soil adhesion for root crops was 500 mg soil kg -1 dry plant and for leafy crops was 5 g kg -1 . Across elements, the log CR was negatively correlated with log Kd (the soil solid/liquid partition coefficient), as expected. Although, this correlation is expected, measures of correlation coefficients suitable for stochastic risk assessment are not frequently reported. The results suggest that r ∼ -0.7 would be appropriate for risk assessment. -- Research highlights: →There are few studies that compare CRs among plant types that encompass both field and garden crops. Here, CRs for 40 elements were measured for 25 crops from farm and garden sites chosen so the grain crops were in close proximity

  1. Determining the Optimum Inner Diameter of Condenser Tubes Based on Thermodynamic Objective Functions and an Economic Analysis

    Directory of Open Access Journals (Sweden)

    Rafał Laskowski

    2016-12-01

    Full Text Available The diameter and configuration of tubes are important design parameters of power condensers. If a proper tube diameter is applied during the design of a power unit, a high energy efficiency of the condenser itself can be achieved and the performance of the whole power generation unit can be improved. If a tube assembly is to be replaced, one should verify whether the chosen condenser tube diameter is correct. Using a diameter that is too large increases the heat transfer area, leading to over-dimensioning and higher costs of building the condenser. On the other hand, if the diameter is too small, water flows faster through the tubes, which results in larger flow resistance and larger pumping power of the cooling-water pump. Both simple and complex methods can be applied to determine the condenser tube diameter. The paper proposes a method of technical and economic optimisation taking into account the performance of a condenser, the low-pressure (LP part of a turbine, and a cooling-water pump as well as the profit from electric power generation and costs of building the condenser and pumping cooling water. The results obtained by this method were compared with those provided by the following simpler methods: minimization of the entropy generation rate per unit length of a condenser tube (considering entropy generation due to heat transfer and resistance of cooling-water flow, minimization of the total entropy generation rate (considering entropy generation for the system comprising the LP part of the turbine, the condenser, and the cooling-water pump, and maximization of the power unit’s output. The proposed methods were used to verify diameters of tubes in power condensers in a200-MW and a 500-MW power units.

  2. On the universality of knot probability ratios

    Energy Technology Data Exchange (ETDEWEB)

    Janse van Rensburg, E J [Department of Mathematics and Statistics, York University, Toronto, Ontario M3J 1P3 (Canada); Rechnitzer, A, E-mail: rensburg@yorku.ca, E-mail: andrewr@math.ubc.ca [Department of Mathematics, University of British Columbia, 1984 Mathematics Road, Vancouver, BC V6T 1Z2 (Canada)

    2011-04-22

    Let p{sub n} denote the number of self-avoiding polygons of length n on a regular three-dimensional lattice, and let p{sub n}(K) be the number which have knot type K. The probability that a random polygon of length n has knot type K is p{sub n}(K)/p{sub n} and is known to decay exponentially with length (Sumners and Whittington 1988 J. Phys. A: Math. Gen. 21 1689-94, Pippenger 1989 Discrete Appl. Math. 25 273-8). Little is known rigorously about the asymptotics of p{sub n}(K), but there is substantial numerical evidence. It is believed that the entropic exponent, {alpha}, is universal, while the exponential growth rate is independent of the knot type but varies with the lattice. The amplitude, C{sub K}, depends on both the lattice and the knot type. The above asymptotic form implies that the relative probability of a random polygon of length n having prime knot type K over prime knot type L. In the thermodynamic limit this probability ratio becomes an amplitude ratio; it should be universal and depend only on the knot types K and L. In this communication we examine the universality of these probability ratios for polygons in the simple cubic, face-centred cubic and body-centred cubic lattices. Our results support the hypothesis that these are universal quantities. For example, we estimate that a long random polygon is approximately 28 times more likely to be a trefoil than be a figure-eight, independent of the underlying lattice, giving an estimate of the intrinsic entropy associated with knot types in closed curves. (fast track communication)

  3. Qualified measurement setup of polarization extinction ratio for Panda PMF with LC/UPC connector

    Science.gov (United States)

    Thongdaeng, Rutsuda; Worasucheep, Duang-rudee; Ngiwprom, Adisak

    2018-03-01

    Polarization Extinction Ratio (PER) is one of the key parameters for Polarization Maintaining Fiber (PMF) connector. Based on our previous studies, the bending radius of fiber greater than 1.5 cm will not affect the insertion loss of PMF [1]. Moreover, the measured PER of Panda PMF with LC/UPC connectors is more stable when that PMF is coiled around a hot rod with a minimum of 3-cm in diameter at 75°C temperature [2]. Hence, the hot rod with less constrained 6-cm in diameter at constant 75°C was selected for this PER measurement. Two PER setups were verified and compared for measuring LC/UPC PMF connectors. The Polarized Laser Source (PLS) at 1550 nm wavelength and PER meter from OZ Optics were used in both setups, in which the measured connector was connected to PLS at 0° angle while the other end was connected to PER meter. In order to qualify our setups, the percentage of Repeatability and Reproducibility (%R&R) were tested and calculated. In each setup, the PER measurement was repeated 3 trials by 3 appraisers using 10 LC/UPC PMF connectors (5 LC/UPC PMF patchcords with 3.5+/-0.5 meters in length) in random order. The 1st setup, PMF was coiled at a larger 20-cm diameter for 3 to 5 loops and left in room temperature during the test. The 2nd setup, PMF was coiled around a hot rod at constant 75°C with 6-cm diameter for 8 to 10 loops for at least 5 minutes before testing. There are 3 ranges of %R&R acceptation guide line: <10% is acceptable, between 10% - 30% is marginal, and <30% is unacceptable. According to our results, the %R&R of the 1st PER test setup was 16.2% as marginality, and the 2nd PER test setup was 8.9% as acceptance. Thus, providing the better repeatability and reproducibility, this 2nd PER test setup having PMF coiled around a hot rod at constant 75°C with 6-cm diameter was selected for our next study of the impact of hot temperature on PER in LC/UPC PMF connector.

  4. An experimental study on two-phase pressure drop in small diameter horizontal, downward inclined and vertical tubes

    Directory of Open Access Journals (Sweden)

    Autee Arun

    2015-01-01

    Full Text Available An experimental study of two-phase pressure drop in small diameter tubes orientated horizontally, vertically and at two other downward inclinations of θ= 300 and θ = 600 is described in this paper. Acrylic transparent tubes of internal diameters 4.0, 6.0, and 8.0 mm with lengths of 400 mm were used as the test section. Air-water mixture was used as the working fluid. Two-phase pressure drop was measured and compared with the existing correlations. These correlations are commonly used for calculation of pressure drop in macro and mini-microchannels. It is observed that the existing correlations are inadequate in predicting the two-phase pressure drop in small diameter tubes. Based on the experimental data, a new correlation has been proposed for predicting the two-phase pressure drop. This correlation is developed by modification of Chisholm parameter C by incorporating different parameters. It was found that the proposed correlation predicted two-phase pressure drop at satisfactory level.

  5. Impact of stent diameter and length on in-stent restenosis after DES vs BMS implantation in patients needing large coronary stents-A clinical and health-economic evaluation

    DEFF Research Database (Denmark)

    Zbinden, Rainer; von Felten, Stefanie; Wein, Bastian

    2017-01-01

    -stent restenosis (ISR) in the BASKET-PROVE study population and evaluated the cost-effectiveness of DES compared to BMS. METHODS/RESULTS: The BASKET-PROVE trial compared DES vs BMS in large coronary arteries (≥3 mm). We calculated incremental cost-effectiveness ratios (ICERs) and cost-effectiveness acceptability...... of 10 000 CHF per TLR avoided, DES had a high probability of being cost-effective. CONCLUSION: In the BASKET-PROVE study population, the strongest predictor of ISR is the use of a BMS, even in patients in need of stents ≥3.0 mm and ≤15 mm lesion length and DES were cost-effective. This should prompt...... compared to segments treated with a DES (5.4% vs 0.76%; P15 mm and ≤15 mm, respectively. With the use of DES in short lesions, there was only a minimal gain of 0.005 in QALYs. At a threshold...

  6. Fission tracks diameters in glasses

    International Nuclear Information System (INIS)

    Garzon Ruiperez, L.; Veiguela, J.

    1974-01-01

    Standard glass microscope slides have been irradiated with fission fragments from the uranium. The etching track conditions have been the same for the series, having changed the etching time only for each specimen. For each glass, a minimum of 250 measurements of the tracks diameters have been made, the distributions of which are the bimodal type. Diameters-etching dependence with time is roughly lineal. Energy determinations have been made with the help of the diameters-energy relations. The calculated values agree very well with the know ones. (author) [es

  7. The effects of session length on demand functions generated using FR schedules.

    Science.gov (United States)

    Foster, T Mary; Kinloch, Jennifer; Poling, Alan

    2011-05-01

    In comparing open and closed economies, researchers often arrange shorter sessions under the former condition than under the latter. Several studies indicate that session length per se can affect performance and there are some data that indicate that this variable can influence demand functions. To provide further data, the present study exposed domestic hens to series of increasing fixed-ratio schedules with the length of the open-economy sessions varied over 10, 40, 60, and 120 min. Session time affected the total-session response rates and pause lengths. The shortest session gave the greatest response rates and shortest pauses and the longest gave the lowest response rates and longest pauses. The total-session demand functions also changed with session length: The shortest session gave steeper initial slopes (i.e., the functions were more elastic at small ratios) and smaller rates of change of elasticity than the longest session. Response rates, pauses, and demand functions were, however, similar for equivalent periods of responding taken from within sessions of different overall lengths (e.g., total-session data for 10-min sessions and the data for the first 10 min of 120-min sessions). These findings suggest that differences in session length can confound the results of studies comparing open and closed economies when those economies are arranged in sessions that differ substantially in length, hence data for equivalent-length periods of responding, rather than total-session data, should be of primary interest under these conditions.

  8. Effect of Amphiphilic Alkyl Chain Length Upon Purified LATEX Stability

    International Nuclear Information System (INIS)

    Amira Amir Hassan; Amir Hashim Mohd Yatim

    2015-01-01

    Rubber particles in purified latex (PL) are stabilized by a film of protein and fatty acid soap (surfactant). Saturated straight-chain fatty acid soaps can assist an enhancement of latex stability. However, whether the alkyl chain length plays an important role in increasing the stability is still an issue. The aim of this study is to investigate the effect of alkyl chain length of anionic surfactant on the stability of purified latex. The fatty acid soap of decanoate (9), laurate (11), sodium dodecyl sulphate (SDS) (12) and palmitate (15) were used. The numbers in parentheses indicating the number of carbon present in alkyl chain of the soap. The results showed that the impact of alkyl chain length on the stability of latex is in the order of laurate > decanoate > SDS > palmitate > purified latex accordingly. The alkyl chain length does giving a significant effect on latex stability after longer stirring time. The particle size of latex with the presence of surfactant is greater compare to a single particle itself due to extension of particles diameter. Thus suitable interaction of the nonpolar tail of surfactant with the hydrophobic regions of latex surface played a major role in maintaining a stable latex system. (author)

  9. Appendiceal diameter: CT versus sonographic measurements

    Energy Technology Data Exchange (ETDEWEB)

    Orscheln, Emily S. [University of Cincinnati Medical Center, Department of Radiology, Cincinnati, OH (United States); Trout, Andrew T. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States)

    2016-03-15

    Ultrasound and CT are the dominant imaging modalities for assessment of suspected pediatric appendicitis, and the most commonly applied diagnostic criterion for both modalities is appendiceal diameter. The classically described cut-off diameter for the diagnosis of appendicitis is 6 mm when using either imaging modality. To demonstrate the fallacy of using the same cut-off diameter for both CT and US in the diagnosis of appendicitis. We conducted a retrospective review of patients younger than 18 years who underwent both US and CT of the appendix within 24 h. The shortest transverse dimension of the appendix was measured at the level of the proximal, mid and distal appendix on US and CT images. We compared mean absolute difference in appendiceal diameter between US and CT, using the paired t-test. We reviewed exams of 155 children (58.7% female) with a mean age of 11.3 ± 4.2 years; 38 of the children (24.5%) were diagnosed with appendicitis. The average time interval between US and CT was 7.0 ± 5.4 h. Mean appendiceal diameter measured by CT was significantly larger than that measured by US in cases without appendicitis (5.3 ± 1.0 mm vs. 4.7 ± 1.1 mm, P < 0.0001) and in cases with appendicitis (8.3 ± 2.2 mm vs. 7.0 ± 2.0 mm, P < 0.0001). Mean absolute diameter difference at any location along the appendix was 1.3-1.4 mm in normal appendices and 2 mm in cases of appendicitis. Measured appendiceal diameter differs between US and CT by 1-2 mm, calling into question use of the same diameter cut-off (6 mm) for both modalities for the diagnosis of appendicitis. (orig.)

  10. Appendiceal diameter: CT versus sonographic measurements

    International Nuclear Information System (INIS)

    Orscheln, Emily S.; Trout, Andrew T.

    2016-01-01

    Ultrasound and CT are the dominant imaging modalities for assessment of suspected pediatric appendicitis, and the most commonly applied diagnostic criterion for both modalities is appendiceal diameter. The classically described cut-off diameter for the diagnosis of appendicitis is 6 mm when using either imaging modality. To demonstrate the fallacy of using the same cut-off diameter for both CT and US in the diagnosis of appendicitis. We conducted a retrospective review of patients younger than 18 years who underwent both US and CT of the appendix within 24 h. The shortest transverse dimension of the appendix was measured at the level of the proximal, mid and distal appendix on US and CT images. We compared mean absolute difference in appendiceal diameter between US and CT, using the paired t-test. We reviewed exams of 155 children (58.7% female) with a mean age of 11.3 ± 4.2 years; 38 of the children (24.5%) were diagnosed with appendicitis. The average time interval between US and CT was 7.0 ± 5.4 h. Mean appendiceal diameter measured by CT was significantly larger than that measured by US in cases without appendicitis (5.3 ± 1.0 mm vs. 4.7 ± 1.1 mm, P < 0.0001) and in cases with appendicitis (8.3 ± 2.2 mm vs. 7.0 ± 2.0 mm, P < 0.0001). Mean absolute diameter difference at any location along the appendix was 1.3-1.4 mm in normal appendices and 2 mm in cases of appendicitis. Measured appendiceal diameter differs between US and CT by 1-2 mm, calling into question use of the same diameter cut-off (6 mm) for both modalities for the diagnosis of appendicitis. (orig.)

  11. Effects of the blockage ratio of a valve disk on loss coefficient in a butterfly valve

    International Nuclear Information System (INIS)

    Rho, Hyung Joon; Lee, Jee Keun; Choi, Hee Joo

    2008-01-01

    The loss coefficient of the butterfly valve which allows partial opening of the valve at closed position and is applicable to the small-sized pipe system with the diameter of 1 inch was measured for the variation of the valve disk blockage ratio. Two different types of the valve disk configuration to adjust the blockage ratio were considered. One was the solid type valve disk of which the diameter was changed into the smaller size rather than the pipe diameter, and the other was the perforate type valve disk on which some holes were perforated. The results from two types of valve disk were compared to identify their characteristics in the loss coefficient distributions. The loss coefficient and the controllable angle of the valve disk were decreased exponentially with the decrease of the blockage ratio. In addition, the perforate valve disk had the effect on the higher loss coefficient rather than the solid type valve disk

  12. Telomere length and early severe social deprivation: linking early adversity and cellular aging

    Science.gov (United States)

    Drury, SS; Theall, K; Gleason, MM; Smyke, AT; De Vivo, I; Wong, JYY; Fox, NA; Zeanah, CH; Nelson, CA

    2012-01-01

    Accelerated telomere length attrition has been associated with psychological stress and early adversity in adults; however, no studies have examined whether telomere length in childhood is associated with early experiences. The Bucharest Early Intervention Project is a unique randomized controlled trial of foster care placement compared with continued care in institutions. As a result of the study design, participants were exposed to a quantified range of time in institutional care, and represented an ideal population in which to examine the association between a specific early adversity, institutional care and telomere length. We examined the association between average relative telomere length, telomere repeat copy number to single gene copy number (T/S) ratio and exposure to institutional care quantified as the percent of time at baseline (mean age 22 months) and at 54 months of age that each child lived in the institution. A significant negative correlation between T/S ratio and percentage of time was observed. Children with greater exposure to institutional care had significantly shorter relative telomere length in middle childhood. Gender modified this main effect. The percentage of time in institutional care at baseline significantly predicted telomere length in females, whereas the percentage of institutional care at 54 months was strongly predictive of telomere length in males. This is the first study to demonstrate an association between telomere length and institutionalization, the first study to find an association between adversity and telomere length in children, and contributes to the growing literature linking telomere length and early adversity. PMID:21577215

  13. Impact of electrocardiogram-gated multi-slice computed tomography-based aortic annular measurement in the evaluation of paravalvular leakage following transcatheter aortic valve replacement: the efficacy of the OverSized AortiC Annular ratio (OSACA ratio) in TAVR.

    Science.gov (United States)

    Maeda, Koichi; Kuratani, Toru; Torikai, Kei; Shimamura, Kazuo; Mizote, Isamu; Ichibori, Yasuhiro; Takeda, Yasuharu; Daimon, Takashi; Nakatani, Satoshi; Nanto, Shinsuke; Sawa, Yoshiki

    2013-07-01

    Even mild paravalvular leakage (PVL) after transcatheter aortic valve replacement (TAVR) is associated with increased late mortality. Electrocardiogram-gated multi-slice computed tomography (MSCT) enables detailed aortic annulus assessment. We describe the impact of MSCT for PVL following TAVR. Congruence between the prosthesis and annulus diameters affects PVL; therefore, we calculated the OverSized AortiC Annular ratio (OSACA ratio) and OSACA (transesophageal echocardiography, TEE) ratio as prosthesis diameter/annulus diameter on MSCT or TEE, respectively, and compared their relationship with PVL ≤ trace following TAVR. Of 36 consecutive patients undergoing TAVR (Group A), the occurrence of PVL ≤ trace (33.3%) was significantly related to the OSACA ratio (p = 0.00020). In receiver-operating characteristics analysis, the cutoff value of 1.03 for the OSACA ratio had the highest sum of sensitivity (75.0%) and specificity (91.7%; AUC = 0.87) with significantly higher discriminatory performance for PVL as compared to the OSACA (TEE) ratio (AUC = 0.69, p = 0.028). In nine consecutive patients (Group B) undergoing TAVR based on guidelines formulated from our experience with Group A, PVL ≤ trace was significantly more frequent (88.9%) than that in Group A (p = 0.0060). The OSACA ratio has a significantly higher discriminatory performance for PVL ≤ trace than the OSACA (TEE) ratio, and aortic annular measurement from MSCT is more accurate than that from TEE. © 2013 Wiley Periodicals, Inc.

  14. Vessel Sampling and Blood Flow Velocity Distribution With Vessel Diameter for Characterizing the Human Bulbar Conjunctival Microvasculature.

    Science.gov (United States)

    Wang, Liang; Yuan, Jin; Jiang, Hong; Yan, Wentao; Cintrón-Colón, Hector R; Perez, Victor L; DeBuc, Delia C; Feuer, William J; Wang, Jianhua

    2016-03-01

    This study determined (1) how many vessels (i.e., the vessel sampling) are needed to reliably characterize the bulbar conjunctival microvasculature and (2) if characteristic information can be obtained from the distribution histogram of the blood flow velocity and vessel diameter. Functional slitlamp biomicroscope was used to image hundreds of venules per subject. The bulbar conjunctiva in five healthy human subjects was imaged on six different locations in the temporal bulbar conjunctiva. The histograms of the diameter and velocity were plotted to examine whether the distribution was normal. Standard errors were calculated from the standard deviation and vessel sample size. The ratio of the standard error of the mean over the population mean was used to determine the sample size cutoff. The velocity was plotted as a function of the vessel diameter to display the distribution of the diameter and velocity. The results showed that the sampling size was approximately 15 vessels, which generated a standard error equivalent to 15% of the population mean from the total vessel population. The distributions of the diameter and velocity were not only unimodal, but also somewhat positively skewed and not normal. The blood flow velocity was related to the vessel diameter (r=0.23, Psampling size of the vessels and the distribution histogram of the blood flow velocity and vessel diameter, which may lead to a better understanding of the human microvascular system of the bulbar conjunctiva.

  15. The Drosophila inner-membrane protein PMI controls crista biogenesis and mitochondrial diameter.

    Science.gov (United States)

    Macchi, Marc; El Fissi, Najla; Tufi, Roberta; Bentobji, Mélanie; Liévens, Jean-Charles; Martins, L Miguel; Royet, Julien; Rival, Thomas

    2013-02-01

    Cristae are mitochondrial inner-membrane structures that concentrate respiratory chain complexes and hence regulate ATP production. Mechanisms controlling crista morphogenesis are poorly understood and few crista determinants have been identified. Among them are the Mitofilins that are required to establish crista junctions and ATP-synthase subunits that bend the membrane at the tips of the cristae. We report here the phenotypic consequences associated with the in vivo inactivation of the inner-membrane protein Pantagruelian Mitochondrion I (PMI) both at the scale of the whole organism, and at the level of mitochondrial ultrastructure and function. We show that flies in which PMI is genetically inactivated experience synaptic defects and have a reduced life span. Electron microscopy analysis of the inner-membrane morphology demonstrates that loss of PMI function increases the average length of mitochondrial cristae in embryonic cells. This phenotype is exacerbated in adult neurons in which cristae form a dense tangle of elongated membranes. Conversely, we show that PMI overexpression is sufficient to reduce crista length in vivo. Finally, these crista defects are associated with impaired respiratory chain activity and increases in the level of reactive oxygen species. Since PMI and its human orthologue TMEM11 are regulators of mitochondrial morphology, our data suggest that, by controlling crista length, PMI influences mitochondrial diameter and tubular shape.

  16. Clinical outcome of narrow-diameter (3.3-mm) locking-taper implants: a prospective study with 1 to 10 years of follow-up.

    Science.gov (United States)

    Mangano, Francesco; Shibli, Jamil A; Sammons, Rachel L; Veronesi, Giovanni; Piattelli, Adriano; Mangano, Carlo

    2014-01-01

    To evaluate the outcome of narrow-diameter (3.3-mm) locking-taper implants used in the rehabilitation of partially and fully edentulous patients over a 10-year period. Between January 2002 and December 2011, all patients referred to a private dental clinic for treatment with narrow-diameter implants were enrolled in this study. At each annual follow-up session, clinical and radiographic parameters were assessed; the outcome measurements were implant failure, peri-implant marginal bone loss (distance between the implant shoulder and the first visible bone-to-implant contact [DIB]), and biologic and technical complications. The cumulative survival rate (CSR) was assessed using the Kaplan-Meier survival estimator; Tarone-Ware and chi-square analyses were used to evaluate correlations between the study variables. The statistical analysis was performed at the patient- and implant-level. A total of 324 narrow-diameter implants were placed in 279 patients (159 men, 120 women; age: 25 to 73 years). Four implants failed, for an overall CSR of 98.5% (patient-based) and 98.7% (implant-based) at the 10-year follow-up. The survival rate did not differ significantly with respect to patients' sex, age, smoking or parafunctional habits, bone type, prosthetic restoration, or implant location, position, or length. Among the surviving implants, a mean DIB of 0.31 ± 0.23 mm, 0.45 ± 0.27 mm, and 0.69 ± 0.28 mm was observed at the 1-, 5-, and 10-year follow-up examinations, respectively. A few biologic (1.2%) and technical complications (7.5%) were reported. Within the limitations of this study, it can be concluded that narrow-diameter locking-taper implants represent a good treatment option for the prosthetic rehabilitation of partially and totally edentulous patients.

  17. A Review of the Segmental Diameter of the Healthy Human Spinal Cord.

    Science.gov (United States)

    Frostell, Arvid; Hakim, Ramil; Thelin, Eric Peter; Mattsson, Per; Svensson, Mikael

    2016-01-01

    Knowledge of the average size and variability of the human spinal cord can be of importance when treating pathological conditions in the spinal cord. Data on healthy human spinal cord morphometrics have been published for more than a century using different techniques of measurements, but unfortunately, comparison of results from different studies is difficult because of the different anatomical landmarks used as reference points along the craniocaudal axis for the measurements. The aim of this review was to compute population estimates of the transverse and anteroposterior diameter of the human spinal cord by comparing and combining previously published data on a normalized craniocaudal axis. We included 11 studies presenting measurements of spinal cord cross-sectional diameters, with a combined sample size ranging from 15 to 488 subjects, depending on spinal cord level. Based on five published studies presenting data on the lengths of the segments of the spinal cord and vertebral column, we calculated the relative positions of all spinal cord neuronal segments and vertebral bony segments and mapped measurements of spinal cord size to a normalized craniocaudal axis. This mapping resulted in better alignment between studies and allowed the calculation of weighted averages and standard deviations (SDs) along the spinal cord. These weighted averages were smoothed using a generalized additive model to yield continuous population estimates for transverse and anteroposterior diameter and associated SDs. The spinal cord had the largest transverse diameter at spinal cord neuronal segment C5 (13.3 ± 2.2), decreased to segment T8 (8.3 ± 2.1), and increased slightly again to 9.4 ± 1.5 at L3. The anteroposterior diameter showed less variation in size along the spinal cord at C5 (7.4 ± 1.6), T8 (6.3 ± 2.0), and L3 (7.5 ± 1.6). All estimates are presented in millimeters ± 2 SDs. We conclude that segmental transverse and anteroposterior

  18. Transabdominal ultrasound measurement of rectal diameter is dependent on time to defecation in constipated children

    DEFF Research Database (Denmark)

    Modin, Line; Dalby, Kasper; Walsted, Anne-Mette

    2015-01-01

    AIM: To study whether diurnal variations and time in relation to defecation has to be taken into account when measurements of rectal diameter are used to determine faecal impaction in constipated children. METHODS: Repeated ultrasound measures of rectal diameter were performed in 28 children (14...... constipated/14 healthy, aged between 4 and 12 years) every third hour during 24 h. After defecation, three additional scans were performed at 1-h intervals. RESULTS: No diurnal variation in rectal diameter was found in the healthy group. In the constipated group, mean rectal diameter was significantly larger...... at 2 pm (P = 0.038) and 5 pm (P = 0.006). There were significant differences between rectal diameter in the healthy group and the constipated group at 2 pm (P = 0.016) and 5 pm (P = 0.027). When we omitted the rectal diameter of five constipated children who had their first bowel movement after 5 pm...

  19. The effect of different temperature profiles upon the length and crystallinity of vertically-aligned multi-walled carbon nanotubes.

    Science.gov (United States)

    Yun, Jongju; Lee, Cheesung; Zheng, Qing; Baik, Seunghyun

    2012-08-01

    We synthesized vertically-aligned multi-walled carbon nanotubes with an inner diameter of 1.6-7.5 nm and stack height of 80-28600 microm by chemical vapor deposition. The effects of synthesis conditions such as substrate position in the tube furnace, maximum temperature, temperature increasing rate and synthesis duration on the structure of nanotubes were investigated. It was found that slightly faster temperature increase rate resulted in significantly longer length, larger diameter and more defects of nanotubes. Structural parameters such as inner, outer diameters, wall thickness and defects were investigated using transmission electron microscopy and Raman spectroscopy.

  20. 7 CFR 51.320 - Diameter.

    Science.gov (United States)

    2010-01-01

    ... Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946... Standards for Grades of Apples Definitions § 51.320 Diameter. When measuring for minimum size, “diameter...

  1. A deceleration system for near-diameter spheres in pipeline transportation in a pebble bed reactor based on the resistance of a pneumatic cushion

    International Nuclear Information System (INIS)

    Liu, Hongbing; He, Ayada; Du, Dong; Wang, Xin; Zhang, Haiquan

    2014-01-01

    Highlights: • A deceleration system for fuel transportation in a pebble bed reactor is designed. • Dynamic analysis and motion analysis of the deceleration process are conducted. • The effectiveness of the system is verified by the analysis and the experiment. • Some key design parameters are studied to achieve effective deceleration. • This research provides a guide for the design of a pebble bed reactor. - Abstract: The fuel elements cycle occurring inside and outside the core of a pebble bed reactor is carried out by pneumatic conveying. In some processes of conveyance, it is necessary to reduce the velocity of the moving fuel element in a short time to avoid damage to the fuel elements and the equipment. In this research, a deceleration system for near-diameter spheres in pipeline transportation based on the resistance of a pneumatic cushion is designed to achieve an effective and reliable deceleration process. Dynamic analysis and motion analysis of the deceleration process are conducted. The results show that when the fuel element is moving in the deceleration pipeline, the gas in the pipeline is compressed to create a pneumatic cushion which resists the movement of the fuel element. In this way, the velocity of the fuel element is decreased to below the target value. During this process, the deceleration is steady and reliable. On this basis some key design parameters are studied, such as the deceleration pipeline length, the ratio of the diameter of the fuel element to the internal diameter of the pipeline, etc. The experimental results are generally consistent with the analysis and demonstrate the considerable effectiveness of the deceleration process as well. This research provides a guide for the design of the fuel elements cycling system in a pebble bed reactor along with the optimization of its control

  2. The effects of axis ratio on laminar fluid flow around an elliptical cylinder

    International Nuclear Information System (INIS)

    Faruquee, Zakir; Ting, David S-K.; Fartaj, Amir; Barron, Ronald M.; Carriveau, Rupp

    2007-01-01

    An elliptical cylinder is a generic shape which represents a flat plate at its minor to major axis ratio (AR) limits of zero and infinity, and a circular cylinder at AR of unity. While incompressible flows over a streamwise flat plate (AR = 0), a cross-stream flat plate (AR = ∞), and a circular cylinder have been studied extensively, the role of AR on the detailed flow structure is still not well understood. Therefore, a numerical study was conducted to examine the flow field around an elliptical cylinder over a range of ARs from 0.3 to 1, with the major axis parallel to the free-stream, at a Reynolds number of 40 based on the hydraulic diameter. The control volume approach of FLUENT was used to solve the fluid flow equations, assuming the flow over the cylinder is unbounded, steady, incompressible and two-dimensional. It has been found that a pair of steady vortices forms when AR reaches a critical value of 0.34; below this value no vortices are formed behind the elliptical cylinder. Various wake parameters, drag coefficient, pressure and velocity distributions, have been characterized as functions of AR. The wake size and the drag coefficient are found to increase with the increase of AR. Quadratic correlations have been obtained to describe the relations of wake length and drag coefficient with axis ratio

  3. Association of newborn diseases with weight/length ratio and the adequacy of weight for gestational age

    Directory of Open Access Journals (Sweden)

    José Ricardo Dias Bertagnon

    2011-09-01

    Full Text Available Objective: To compare the frequencies of newborn diseases in thosenewborns classified according to a weight/length rate and thoseclassified by the adequacy weight for gestational age. Methods: Aretrospective cross-sectional study by record assessment was carriedout enclosing all the live newborns at Hospital Geral do Grajaú, fromSeptember to December, 2009 (n =577 classified according to therate weight/length and also to the adequacy weight for gestationalage. The 10 and 90 percentiles of the weight/length distribution, nowdesignated as “indices” were calculated leading to the followingclassification: low index, for newborns below 54.8 g/cm; high index,for those over 75.8 g/cm; and average index, for the remainingnewborns. According to the adequacy weight for gestational age thenewborns were designated as pre-term for gestational age; term smallfor gestational age; appropriate term and large term. In this samplethere were no small and large pre-term or post-term newborns. Majordiseases were related to the index and adequacy extracts by the χ2test for a contingency table. Results: A significant association wasfound among low index, pre-term for gestational age newborns andterm small for gestational age; between average index and appropriatefor gestational age term newborns; and high index with large termappropriate for gestational age newborns (p< 0.001. Hypoglycemia(3.4% was associated to both low and high indices, to appropriatefor gestational age preterm newborns and to small for gestational ageterm newborns. Sepsis (3.1% was associated to both low index andpre-term appropriate for gestational age newborns. The respiratorydistress syndrome (1.3% was associated to low index and pre-termappropriate for gestational age newborns. Other respiratory distresssyndromes (3.8% were associated to low and high indices but notto the adequacy for gestational age classification. Jaundice (14.9%was not associated to the studied classifications

  4. Single-Camera-Based Method for Step Length Symmetry Measurement in Unconstrained Elderly Home Monitoring.

    Science.gov (United States)

    Cai, Xi; Han, Guang; Song, Xin; Wang, Jinkuan

    2017-11-01

    single-camera-based gait monitoring is unobtrusive, inexpensive, and easy-to-use to monitor daily gait of seniors in their homes. However, most studies require subjects to walk perpendicularly to camera's optical axis or along some specified routes, which limits its application in elderly home monitoring. To build unconstrained monitoring environments, we propose a method to measure step length symmetry ratio (a useful gait parameter representing gait symmetry without significant relationship with age) from unconstrained straight walking using a single camera, without strict restrictions on walking directions or routes. according to projective geometry theory, we first develop a calculation formula of step length ratio for the case of unconstrained straight-line walking. Then, to adapt to general cases, we propose to modify noncollinear footprints, and accordingly provide general procedure for step length ratio extraction from unconstrained straight walking. Our method achieves a mean absolute percentage error (MAPE) of 1.9547% for 15 subjects' normal and abnormal side-view gaits, and also obtains satisfactory MAPEs for non-side-view gaits (2.4026% for 45°-view gaits and 3.9721% for 30°-view gaits). The performance is much better than a well-established monocular gait measurement system suitable only for side-view gaits with a MAPE of 3.5538%. Independently of walking directions, our method can accurately estimate step length ratios from unconstrained straight walking. This demonstrates our method is applicable for elders' daily gait monitoring to provide valuable information for elderly health care, such as abnormal gait recognition, fall risk assessment, etc. single-camera-based gait monitoring is unobtrusive, inexpensive, and easy-to-use to monitor daily gait of seniors in their homes. However, most studies require subjects to walk perpendicularly to camera's optical axis or along some specified routes, which limits its application in elderly home monitoring

  5. Genetic variation in pea (Pisum sativum L.) demonstrates the importance of root but not shoot C/N ratios in the control of plant morphology and reveals a unique relationship between shoot length and nodulation intensity.

    Science.gov (United States)

    Ludidi, Ndiko N; Pellny, Till K; Kiddle, Guy; Dutilleul, Christelle; Groten, Karin; VAN Heerden, Philippus D R; Dutt, Som; Powers, Stephen J; Römer, Peter; Foyer, Christine H

    2007-10-01

    Nodule numbers are regulated through systemic auto-regulatory signals produced by shoots and roots. The relative effects of shoot and root genotype on nodule numbers together with relationships to organ biomass, carbon (C) and nitrogen (N) status, and related parameters were measured in pea (Pisum sativum) exploiting natural genetic variation in maturity and apparent nodulation intensity. Reciprocal grafting experiments between the early (Athos), intermediate (Phönix) and late (S00182) maturity phenotypes were performed and Pearson's correlation coefficients for the parameters were calculated. No significant correlations were found between shoot C/N ratios and plant morphology parameters, but the root C/N ratio showed a strong correlation with root fresh and dry weights as well as with shoot fresh weight with less significant interactions with leaf number. Hence, the root C/N ratio rather than shoot C/N had a predominant influence on plant morphology when pea plants are grown under conditions of symbiotic nitrogen supply. The only phenotypic characteristic that showed a statistically significant correlation with nodulation intensity was shoot length, which accounted for 68.5% of the variation. A strong linear relationship was demonstrated between shoot length and nodule numbers. Hence, pea nodule numbers are controlled by factors related to shoot extension, but not by shoot or root biomass accumulation, total C or total N. The relationship between shoot length and nodule numbers persisted under field conditions. These results suggest that stem height could be used as a breeding marker for the selection of pea cultivars with high nodule numbers and high seed N contents.

  6. Interfacial area concentration in gas–liquid bubbly to churn flow regimes in large diameter pipes

    International Nuclear Information System (INIS)

    Shen, Xiuzhong; Hibiki, Takashi

    2015-01-01

    Highlights: • A systematic method to predict interfacial area concentration (IAC) is presented. • A correlation for group 1 bubble void fraction is proposed. • Correlations of IAC and bubble diameter are developed for group 1 bubbles. • Correlations of IAC and bubble diameter are developed for group 2 bubbles. • The newly-developed two-group IAC model compares well with collected databases. - Abstract: This study performed a survey on existing correlations for interfacial area concentration (IAC) prediction and collected an IAC experimental database of two-phase flows taken under various flow conditions in large diameter pipes. Although some of these existing correlations were developed by partly using the IAC databases taken in the low-void-fraction two-phase flows in large diameter pipes, no correlation can satisfactorily predict the IAC in the two-phase flows changing from bubbly, cap bubbly to churn flow in the collected database of large diameter pipes. So this study presented a systematic way to predict the IAC for the bubbly-to-churn flows in large diameter pipes by categorizing bubbles into two groups (group 1: spherical or distorted bubble, group 2: cap bubble). A correlation was developed to predict the group 1 void fraction by using the void fraction for all bubble. The group 1 bubble IAC and bubble diameter were modeled by using the key parameters such as group 1 void fraction and bubble Reynolds number based on the analysis of Hibiki and Ishii (2001, 2002) using one-dimensional bubble number density and interfacial area transport equations. The correlations of IAC and bubble diameter for group 2 cap bubbles were developed by taking into account the characteristics of the representative bubbles among the group 2 bubbles and the comparison between a newly-derived drift velocity correlation for large diameter pipes and the existing drift velocity correlation of Kataoka and Ishii (1987) for large diameter pipes. The predictions from the newly

  7. Tau hadronic branching ratios

    CERN Document Server

    Buskulic, Damir; De Bonis, I; Décamp, D; Ghez, P; Goy, C; Lees, J P; Lucotte, A; Minard, M N; Odier, P; Pietrzyk, B; Ariztizabal, F; Chmeissani, M; Crespo, J M; Efthymiopoulos, I; Fernández, E; Fernández-Bosman, M; Gaitan, V; Martínez, M; Orteu, S; Pacheco, A; Padilla, C; Palla, Fabrizio; Pascual, A; Perlas, J A; Sánchez, F; Teubert, F; Colaleo, A; Creanza, D; De Palma, M; Farilla, A; Gelao, G; Girone, M; Iaselli, Giuseppe; Maggi, G; Maggi, M; Marinelli, N; Natali, S; Nuzzo, S; Ranieri, A; Raso, G; Romano, F; Ruggieri, F; Selvaggi, G; Silvestris, L; Tempesta, P; Zito, G; Huang, X; Lin, J; Ouyang, Q; Wang, T; Xie, Y; Xu, R; Xue, S; Zhang, J; Zhang, L; Zhao, W; Bonvicini, G; Cattaneo, M; Comas, P; Coyle, P; Drevermann, H; Engelhardt, A; Forty, Roger W; Frank, M; Hagelberg, R; Harvey, J; Jacobsen, R; Janot, P; Jost, B; Kneringer, E; Knobloch, J; Lehraus, Ivan; Markou, C; Martin, E B; Mato, P; Minten, Adolf G; Miquel, R; Oest, T; Palazzi, P; Pater, J R; Pusztaszeri, J F; Ranjard, F; Rensing, P E; Rolandi, Luigi; Schlatter, W D; Schmelling, M; Schneider, O; Tejessy, W; Tomalin, I R; Venturi, A; Wachsmuth, H W; Wiedenmann, W; Wildish, T; Witzeling, W; Wotschack, J; Ajaltouni, Ziad J; Bardadin-Otwinowska, Maria; Barrès, A; Boyer, C; Falvard, A; Gay, P; Guicheney, C; Henrard, P; Jousset, J; Michel, B; Monteil, S; Pallin, D; Perret, P; Podlyski, F; Proriol, J; Rossignol, J M; Saadi, F; Fearnley, Tom; Hansen, J B; Hansen, J D; Hansen, J R; Hansen, P H; Nilsson, B S; Kyriakis, A; Simopoulou, Errietta; Siotis, I; Vayaki, Anna; Zachariadou, K; Blondel, A; Bonneaud, G R; Brient, J C; Bourdon, P; Passalacqua, L; Rougé, A; Rumpf, M; Tanaka, R; Valassi, Andrea; Verderi, M; Videau, H L; Candlin, D J; Parsons, M I; Focardi, E; Parrini, G; Corden, M; Delfino, M C; Georgiopoulos, C H; Jaffe, D E; Antonelli, A; Bencivenni, G; Bologna, G; Bossi, F; Campana, P; Capon, G; Chiarella, V; Felici, G; Laurelli, P; Mannocchi, G; Murtas, F; Murtas, G P; Pepé-Altarelli, M; Dorris, S J; Halley, A W; ten Have, I; Knowles, I G; Lynch, J G; Morton, W T; O'Shea, V; Raine, C; Reeves, P; Scarr, J M; Smith, K; Smith, M G; Thompson, A S; Thomson, F; Thorn, S; Turnbull, R M; Becker, U; Braun, O; Geweniger, C; Graefe, G; Hanke, P; Hepp, V; Kluge, E E; Putzer, A; Rensch, B; Schmidt, M; Sommer, J; Stenzel, H; Tittel, K; Werner, S; Wunsch, M; Beuselinck, R; Binnie, David M; Cameron, W; Colling, D J; Dornan, Peter J; Konstantinidis, N P; Moneta, L; Moutoussi, A; Nash, J; San Martin, G; Sedgbeer, J K; Stacey, A M; Dissertori, G; Girtler, P; Kuhn, D; Rudolph, G; Bowdery, C K; Brodbeck, T J; Colrain, P; Crawford, G; Finch, A J; Foster, F; Hughes, G; Sloan, Terence; Whelan, E P; Williams, M I; Galla, A; Greene, A M; Kleinknecht, K; Quast, G; Raab, J; Renk, B; Sander, H G; Wanke, R; Van Gemmeren, P; Zeitnitz, C; Aubert, Jean-Jacques; Bencheikh, A M; Benchouk, C; Bonissent, A; Bujosa, G; Calvet, D; Carr, J; Diaconu, C A; Etienne, F; Thulasidas, M; Nicod, D; Payre, P; Rousseau, D; Talby, M; Abt, I; Assmann, R W; Bauer, C; Blum, Walter; Brown, D; Dietl, H; Dydak, Friedrich; Ganis, G; Gotzhein, C; Jakobs, K; Kroha, H; Lütjens, G; Lutz, Gerhard; Männer, W; Moser, H G; Richter, R H; Rosado-Schlosser, A; Schael, S; Settles, Ronald; Seywerd, H C J; Saint-Denis, R; Wolf, G; Alemany, R; Boucrot, J; Callot, O; Cordier, A; Courault, F; Davier, M; Duflot, L; Grivaz, J F; Heusse, P; Jacquet, M; Kim, D W; Le Diberder, F R; Lefrançois, J; Lutz, A M; Musolino, G; Nikolic, I A; Park, H J; Park, I C; Schune, M H; Simion, S; Veillet, J J; Videau, I; Abbaneo, D; Azzurri, P; Bagliesi, G; Batignani, G; Bettarini, S; Bozzi, C; Calderini, G; Carpinelli, M; Ciocci, M A; Ciulli, V; Dell'Orso, R; Fantechi, R; Ferrante, I; Foà, L; Forti, F; Giassi, A; Giorgi, M A; Gregorio, A; Ligabue, F; Lusiani, A; Marrocchesi, P S; Messineo, A; Rizzo, G; Sanguinetti, G; Sciabà, A; Spagnolo, P; Steinberger, Jack; Tenchini, Roberto; Tonelli, G; Triggiani, G; Vannini, C; Verdini, P G; Walsh, J; Betteridge, A P; Blair, G A; Bryant, L M; Cerutti, F; Gao, Y; Green, M G; Johnson, D L; Medcalf, T; Mir, L M; Perrodo, P; Strong, J A; Bertin, V; Botterill, David R; Clifft, R W; Edgecock, T R; Haywood, S; Edwards, M; Maley, P; Norton, P R; Thompson, J C; Bloch-Devaux, B; Colas, P; Emery, S; Kozanecki, Witold; Lançon, E; Lemaire, M C; Locci, E; Marx, B; Pérez, P; Rander, J; Renardy, J F; Roussarie, A; Schuller, J P; Schwindling, J; Trabelsi, A; Vallage, B; Johnson, R P; Kim, H Y; Litke, A M; McNeil, M A; Taylor, G; Beddall, A; Booth, C N; Boswell, R; Cartwright, S L; Combley, F; Dawson, I; Köksal, A; Letho, M; Newton, W M; Rankin, C; Thompson, L F; Böhrer, A; Brandt, S; Cowan, G D; Feigl, E; Grupen, Claus; Lutters, G; Minguet-Rodríguez, J A; Rivera, F; Saraiva, P; Smolik, L; Stephan, F; Apollonio, M; Bosisio, L; Della Marina, R; Giannini, G; Gobbo, B; Ragusa, F; Rothberg, J E; Wasserbaech, S R; Armstrong, S R; Bellantoni, L; Elmer, P; Feng, Z; Ferguson, D P S; Gao, Y S; González, S; Grahl, J; Harton, J L; Hayes, O J; Hu, H; McNamara, P A; Nachtman, J M; Orejudos, W; Pan, Y B; Saadi, Y; Schmitt, M; Scott, I J; Sharma, V; Turk, J; Walsh, A M; Wu Sau Lan; Wu, X; Yamartino, J M; Zheng, M; Zobernig, G

    1996-01-01

    From 64492 selected \\tau-pair events, produced at the Z^0 resonance, the measurement of the tau decays into hadrons from a global analysis using 1991, 1992 and 1993 ALEPH data is presented. Special emphasis is given to the reconstruction of photons and \\pi^0's, and the removal of fake photons. A detailed study of the systematics entering the \\pi^0 reconstruction is also given. A complete and consistent set of tau hadronic branching ratios is presented for 18 exclusive modes. Most measurements are more precise than the present world average. The new level of precision reached allows a stringent test of \\tau-\\mu universality in hadronic decays, g_\\tau/g_\\mu \\ = \\ 1.0013 \\ \\pm \\ 0.0095, and the first measurement of the vector and axial-vector contributions to the non-strange hadronic \\tau decay width: R_{\\tau ,V} \\ = \\ 1.788 \\ \\pm \\ 0.025 and R_{\\tau ,A} \\ = \\ 1.694 \\ \\pm \\ 0.027. The ratio (R_{\\tau ,V} - R_{\\tau ,A}) / (R_{\\tau ,V} + R_{\\tau ,A}), equal to (2.7 \\pm 1.3) \\ \\%, is a measure of the importance of Q...

  8. Leg length, sitting height, and body proportions references for achondroplasia: New tools for monitoring growth.

    Science.gov (United States)

    Del Pino, Mariana; Ramos Mejía, Rosario; Fano, Virginia

    2018-04-01

    Achondroplasia is the most common form of inherited disproportionate short stature. We report leg length, sitting height, and body proportion curves for achondroplasia. Seven centile format of sitting height, leg length, sitting height/leg length ratio, sitting height/height ratio, and head circumference/height ratio were estimated by the LMS method. The Q-test was applied to assess the goodness of fit. For comparison, centiles of sitting height and leg length were graphed using Argentine national growth references for achondroplasia and non-achondroplasia populations. The sample consisted of 342 children with achondroplasia (171 males, 171 females) aged 0-18 years. The median (interquartile range) number of measurements per child was 6 (3, 12) for sitting height and 8 (3, 13) for head circumference. Median leg length increased from 14 cm at age 1 week to 44 and 40 cm (males and females, respectively) in achondroplasia adolescents which is 3.5 cm shorter than non-achondroplasia children at age 1 week and, 38 cm shorter at adolescence. Median sitting height increased from 34 cm at birth to 86 and 81 in adolescents' boys and girls respectively, only 5 cm shorter than non-achondroplasia children. Sitting height/leg length decreased from 2.61 at birth to approximately 1.90 at adolescent. Median head circumference/height ratio decreased from 0.79 at birth to 0.46 at 18 years in both sexes. Growth of lower limbs is affected early in life and becomes more noticeable throughout childhood. The disharmonic growth between the less affected trunk and the severely affected limbs determine body disproportion in achondroplasia. © 2018 Wiley Periodicals, Inc.

  9. Beam depolarization and gain saturation in neodymium rods with a diameter of 85 mm

    Energy Technology Data Exchange (ETDEWEB)

    Sukhanov, V N; Ugodenko, A A

    1990-04-01

    Depolarization and gain saturation were investigated in rod amplifiers using phosphate and silicate Nd glasses 85 mm in diameter and 300 mm in length at a pulse duration of 35 ns. Total depolarization losses over the rod cross section were measured for various radial distributions of the small-signal gain. For the phosphate glass the losses amounted to 3-6 percent; for the silicate glass, they amounted to 4-7 percent. Saturation energy densities of 4.5 + or - 0.4 and 8.0 + or - 0.7 J/sq cm were obtained for the phosphate and silicate glass, respectively. 8 refs.

  10. Evaluation of the normal thoracic and abdominal aorta diameters by computerized tomography; Avaliacao dos diametros normais da aorta toracica e abdominal pela tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Lucarelli, Claudio Luiz

    1995-07-01

    The study was undertaken to evaluate, through computerized tomography, the diameters of the normal thoracic and abdominal aorta, as well as they are connected to gender, age and body surface area; and the ratio between measurements obtained at the ascending and descending limbs of the thoracic aorta, and between the abdominal aortic diameters. For that reason, we measured the widest anteroposterior diameters of the thoracic aortas at the levels of the arch, the root, the pulmonary artery, and the thoracic-abdominal transition, as well as the level of the emergence of the superior mesenteric artery, of the renal hila and just cephalad to the bifurcation of the abdominal aortas of 350 patients without cardiovascular diseases who had undergone computerized tomography of the thorax and/or abdomen for any other reasons. Observation and statistic analyses led us to conclude that: 1) both the thoracic and abdominal aortic diameters are reduced from their proximal to their distal portions; 2) the body surface influences the size of the aorta, although only extreme variations alter the vessel's caliber; 3) vessel diameter was observed to gradually increase with age; 4) men were found to have larger diameters than age matched women; 5) the ratio between the ascending and descending aortic diameters varies according to gender and age; 6) the relations between abdominal aortic diameters measured at the level of renal hila and cephalad to the bifurcation are independent from gender and age. But the relation between those measured at the level of the superior mesenteric artery and cephalad to the bifurcation are linked to gender, but not to age. (author)

  11. Evaluation of the normal thoracic and abdominal aorta diameters by computerized tomography; Avaliacao dos diametros normais da aorta toracica e abdominal pela tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Lucarelli, Claudio Luiz

    1995-07-01

    The study was undertaken to evaluate, through computerized tomography, the diameters of the normal thoracic and abdominal aorta, as well as they are connected to gender, age and body surface area; and the ratio between measurements obtained at the ascending and descending limbs of the thoracic aorta, and between the abdominal aortic diameters. For that reason, we measured the widest anteroposterior diameters of the thoracic aortas at the levels of the arch, the root, the pulmonary artery, and the thoracic-abdominal transition, as well as the level of the emergence of the superior mesenteric artery, of the renal hila and just cephalad to the bifurcation of the abdominal aortas of 350 patients without cardiovascular diseases who had undergone computerized tomography of the thorax and/or abdomen for any other reasons. Observation and statistic analyses led us to conclude that: 1) both the thoracic and abdominal aortic diameters are reduced from their proximal to their distal portions; 2) the body surface influences the size of the aorta, although only extreme variations alter the vessel's caliber; 3) vessel diameter was observed to gradually increase with age; 4) men were found to have larger diameters than age matched women; 5) the ratio between the ascending and descending aortic diameters varies according to gender and age; 6) the relations between abdominal aortic diameters measured at the level of renal hila and cephalad to the bifurcation are independent from gender and age. But the relation between those measured at the level of the superior mesenteric artery and cephalad to the bifurcation are linked to gender, but not to age. (author)

  12. Compressive buckling of black phosphorene nanotubes: an atomistic study

    Science.gov (United States)

    Nguyen, Van-Trang; Le, Minh-Quy

    2018-04-01

    We investigate through molecular dynamics finite element method with Stillinger-Weber potential the uniaxial compression of armchair and zigzag black phosphorene nanotubes. We focus especially on the effects of the tube’s diameter with fixed length-diameter ratio, effects of the tube’s length for a pair of armchair and zigzag tubes of equal diameters, and effects of the tube’s diameter with fixed lengths. Their Young’s modulus, critical compressive stress and critical compressive strain are studied and discussed for these 3 case studies. Compressive buckling was clearly observed in the armchair nanotubes. Local bond breaking near the boundary occurred in the zigzag ones under compression.

  13. Influence of crack length on crack depth measurement by an alternating current potential drop technique

    International Nuclear Information System (INIS)

    Raja, Manoj K; Mahadevan, S; Rao, B P C; Behera, S P; Jayakumar, T; Raj, Baldev

    2010-01-01

    An alternating current potential drop (ACPD) technique is used for sizing depth of surface cracks in metallic components. Crack depth estimations are prone to large deviations when ACPD measurements are made on very shallow and finite length cracks, especially in low conducting materials such as austenitic stainless steel (SS). Detailed studies have been carried out to investigate the influence of crack length and aspect ratio (length to depth) on depth estimation by performing measurements on electric discharge machined notches with the aspect ratio in the range of 1 to 40 in SS plates. In notches with finite length, an additional path for current to flow through the surface along the length is available causing the notch depths to be underestimated. The experimentally observed deviation in notch depth estimates is explained from a simple mathematical approach using the equivalent resistive circuit model based on the additional path available for the current to flow. A scheme is proposed to accurately measure the depth of cracks with finite lengths in SS components

  14. Osseointegration of Implants Surface-Treated with Various Diameters of TiO2 Nanotubes in Rabbit

    Directory of Open Access Journals (Sweden)

    Cheul-Goo Kang

    2015-01-01

    Full Text Available The aim of this study was to evaluate the osseointegration of implants which were surface-treated with various diameters of TiO2 nanotubes (30 nm, 70 nm, and 100 nm in rabbit. Resorbable blast media (RBM surfaced implants (Osstem, Busan, Korea 3.5 mm in diameter and 8.5 mm in length were designated as the control group and the implants surface-treated with various diameters of nanotubes (30 nm, 70 nm, and 100 nm with the same shapes were designated as the experimental groups. The implants were maintained unloaded for 4 and 12 weeks. After this period, the animals were sacrificed and micro-CT analysis, histomorphometric analysis (bone to implant contact (BIC, bone volume (BV, and removal torque test were performed. Micro-CT analysis, histomorphometric analysis, and removal torque test results all showed the similar pattern, showing that 70 nm experimental group had the highest value at 4 weeks while 30 nm experimental group had the highest value at 12 weeks. Therefore, on the basis of the results above, it can be concluded that 30 nm and 70 nm TiO2 nanotubes may have positive effects on osteogenesis and osseointegration depending on the healing time.

  15. Association of body mass index, sagittal abdominal diameter and waist-hip ratio with cardiometabolic risk factors and adipocytokines in Arab children and adolescents

    Directory of Open Access Journals (Sweden)

    Al-Attas Omar S

    2012-08-01

    Full Text Available Abstract Background Sagittal abdominal diameter (SAD is a novel anthropometric measure hypothesized to be a surrogate measure of visceral abdominal obesity in adults. This study aims to determine whether SAD is superior to other anthropometric measures such as body mass index (BMI and waist to hip ratio (WHR in terms of association to cardiometabolic risk and circulating adipocytokine concentrations in a cohort of Saudi children and adolescents. Methods A total of 948 (495 boys and 453 girls apparently healthy children with varying BMI, aged 10–17 years, were included in this cross sectional study. Fasting glucose, lipid profile, leptin, adiponectin, resistin, insulin, TNF-α and aPAI-1 were measured in serum and HOMA-IR was calculated. MetS components were defined according to the International Diabetes Federation (IDF criteria. Results BMI was superior to SAD as well as WHR, and had the highest number of significant associations to MetS components and adipocytokines even after adjustment for age and gender, including blood pressure, lipids, glucose and leptin. Conclusion In conclusion, while SAD is significantly associated with components of MetS among children and adolescents, it is not superior to BMI. The use of SAD therefore may not be practical for use in the pediatric clinical setting. Follow-up studies are needed to determine whether SAD has clinical significance in terms of harder outcomes such as predicting diabetes mellitus or cardiovascular diseases.

  16. Experimental investigation for the optimization of heat pipe performance in latent heat thermal storage

    Energy Technology Data Exchange (ETDEWEB)

    Ladekar, Chandrakishor; Choudhary, S. K. [RTM Nagpur University, Wardha (India); Khandare, S. S. [B. D. College of Engineering, Wardha (India)

    2017-06-15

    We investigated the optimum performance of heat pipe in Latent heat thermal energy storage (LHTES), and compared it with copper pipe. Classical plan of experimentation was used to optimize the parameters of heat pipe. Heat pipe fill ratio, evaporator section length to condenser section length ratio i.e., Heat pipe length ratio (HPLR) and heat pipe diameter, was the parameter used for optimization, as result of parametric analysis. Experiment with flow rate of 10 lit./min. was conducted for different fill ratio, HPLR and different diameter. Fill ratio of 80 %, HPLR of 0.9 and heat pipe with diameter of 18 mm showed better trend in charging and discharging. Comparison between the storage tank with optimized heat pipe and copper pipe showed almost 186 % improvement in charging and discharging time compared with the copper pipe embedded thermal storage. Heat transfer between Heat transferring fluid (HTF) and Phase change material (PCM) increased with increase in area of heat transferring media, but storage density of storage tank decreased. Storage tank with heat pipe embedded in place of copper pipe is a better option in terms of charging and discharging time as well heat storage capacity due to less heat lost. This justifies the better efficiency and effectiveness of storage tank with embedded optimized heat pipe.

  17. Biofilm formation on a TiO2 nanotube with controlled pore diameter and surface wettability

    International Nuclear Information System (INIS)

    Anitha, V C; Narayan Banerjee, Arghya; Woo Joo, Sang; Lee, Jin-Hyung; Lee, Jintae; Ki Min, Bong

    2015-01-01

    Titania (TiO 2 ) nanotube arrays (TNAs) with different pore diameters (140 − 20 nm) are fabricated via anodization using hydrofluoric acid (HF) containing ethylene glycol (EG) by changing the HF-to-EG volume ratio and the anodization voltage. To evaluate the effects of different pore diameters of TiO 2 nanotubes on bacterial biofilm formation, Shewanella oneidensis (S. oneidensis) MR-1 cells and a crystal-violet biofilm assay are used. The surface roughness and wettability of the TNA surfaces as a function of pore diameter, measured via the contact angle and AFM techniques, are correlated with the controlled biofilm formation. Biofilm formation increases with the decreasing nanotube pore diameter, and a 20 nm TiO 2 nanotube shows the maximum biofilm formation. The measurements revealed that 20 nm surfaces have the least hydrophilicity with the highest surface roughness of ∼17 nm and that they show almost a 90% increase in the effective surface area relative to the 140 nm TNAs, which stimulate the cells more effectively to produce the pili to attach to the surface for more biofilm formation. The results demonstrate that bacterial cell adhesion (and hence, biofilm formation) can effectively be controlled by tuning the roughness and wettability of TNAs via controlling the pore diameters of TNA surfaces. This biofilm formation as a function of the surface properties of TNAs can be a potential candidate for both medical applications and as electrodes in microbial fuel cells. (paper)

  18. Evaluation of the normal fetal kidney length and its correlation with gestational age.

    Science.gov (United States)

    Seilanian Toosi, Farrokh; Rezaie-Delui, Hossein

    2013-05-30

    A true estimation of gestational age (GA) plays an important role in quality maternity care and scheduling the labor date. This study aimed to evaluate the normal fetal kidney length (KL) and its correlation with GA. A cross-sectional study on 92 pregnant women between 8th and 10th week of gestation with normal singleton pregnancy underwent standard ultrasound fetal biometry and kidney length measurement. univariate and multivariate linear regression analysis was used to create a predictive equation to estimate GA on the KL and fetobiometry parameters. A significant correlation was found between GA and KL (r=0.83, P<0.002). The best GA predictor was obtained by combining head circumference, fetal biparietal diameter, femur length and KL with a standard error (SE) about 14.2 days. Our findings showed that KL measurements combination with other fetal biometric parameters could predict age of pregnancy with a better precision.

  19. Optimum copper to superconductor ratio in cables for superconducting magnets at 1.9 K

    International Nuclear Information System (INIS)

    Wolf, R.

    1994-01-01

    In this paper the optimum copper to superconducting ratio is calculated to prevent quenching for superconducting cables used in accelerator magnets like the LHC dipoles, operating in superfluid helium at 1.9K. The duration of the perturbations leading to a quench are estimated from flux measurements made with pickup coils in the LHC dipole models. The optimum copper to superconducting ratio is then found by studying the minimum quench energy and the influence of the length and the duration or the perturbation and heat transfer to the surroundings. A comparison is made of the behavior at temperatures of 1.9 and 4.3 K

  20. CFD modeling using PDF approach for investigating the flame length in rotary kilns

    Science.gov (United States)

    Elattar, H. F.; Specht, E.; Fouda, A.; Bin-Mahfouz, Abdullah S.

    2016-12-01

    Numerical simulations using computational fluid dynamics (CFD) are performed to investigate the flame length characteristics in rotary kilns using probability density function (PDF) approach. A commercial CFD package (ANSYS-Fluent) is employed for this objective. A 2-D axisymmetric model is applied to study the effect of both operating and geometric parameters of rotary kiln on the characteristics of the flame length. Three types of gaseous fuel are used in the present work; methane (CH4), carbon monoxide (CO) and biogas (50 % CH4 + 50 % CO2). Preliminary comparison study of 2-D modeling outputs of free jet flames with available experimental data is carried out to choose and validate the proper turbulence model for the present numerical simulations. The results showed that the excess air number, diameter of kiln air entrance, radiation modeling consideration and fuel type have remarkable effects on the flame length characteristics. Numerical correlations for the rotary kiln flame length are presented in terms of the studied kiln operating and geometric parameters within acceptable error.

  1. Revisiting the concept of Redfield ratios applied to plankton stoichiometry - Addressing model uncertainties with respect to the choice of C:N:P ratios for phytoplankton

    Science.gov (United States)

    Kreus, Markus; Paetsch, Johannes; Grosse, Fabian; Lenhart, Hermann; Peck, Myron; Pohlmann, Thomas

    2017-04-01

    variations appear in the central and northern North Sea with persistent seasonal stratification. Our results show that a moderate variation of the elemental ratios of phytoplankton, which can be found in literature, yields relatively strong variations in marine biochemical key processes. This puts emphasis on the uncertainties in predicting ecosystem response to OA or climate change using ecosystem models.

  2. A Method for Determining Skeletal Lengths from DXA Images

    Directory of Open Access Journals (Sweden)

    Fogelman Ignac

    2007-11-01

    Full Text Available Abstract Background Skeletal ratios and bone lengths are widely used in anthropology and forensic pathology and hip axis length is a useful predictor of fracture. The aim of this study was to show that skeletal ratios, such as length of femur to height, could be accurately measured from a DXA (dual energy X-ray absorptiometry image. Methods 90 normal Caucasian females, 18–80 years old, with whole body DXA data were used as subjects. Two methods, linear pixel count (LPC and reticule and ruler (RET were used to measure skeletal sizes on DXA images and compared with real clinical measures from 20 subjects and 20 x-rays of the femur and tibia taken in 2003. Results Although both methods were highly correlated, the LPC inter- and intra-observer error was lower at 1.6% compared to that of RET at 2.3%. Both methods correlated positively with real clinical measures, with LPC having a marginally stronger correlation coefficient (r2 = 0.94; r2 = 0.84; average r2 = 0.89 than RET (r2 = 0.86; r2 = 0.84; average r2 = 0.85 with X-rays and real measures respectively. Also, the time taken to use LPC was half that of RET at 5 minutes per scan. Conclusion Skeletal ratios can be accurately and precisely measured from DXA total body scan images. The LPC method is easy to use and relatively rapid. This new phenotype will be useful for osteoporosis research for individuals or large-scale epidemiological or genetic studies.

  3. Transient desorption characteristics of fibrous organic adsorbent; Sen'ikei yuki kyuchakuzai no katoteki dacchaku tokusei

    Energy Technology Data Exchange (ETDEWEB)

    Inaba, H.; Ozaki, K.; Horibe, A. [Okayama University, Okayama (Japan). Faculty of Engineering; Shimoyama, R. [Okayama University, Okayama (Japan); Kida, T. [Japan Exlan Co. Ltd., Osaka (Japan)

    1999-11-25

    An experimental investigation was performed to determine time transient desorption characteristics of a fibrous type organic adsorbent, which was composed of the bridged complex of sodium polyacrylate as a new kind of adsorbent. The test fibrous adsorbent was packed in a cylindrical vessel, and dry air was passed through it. The experiments were conducted under various conditions of air velocity, temperature, relative humidity and vessel length. As a result, time pressure loss for the packed bed of the test fibrous adsorbent showed a similar tendency to that for the packed bed of spherical particles. The mass transfer data was correlated by the modified Sherwood number, the Reynolds number, the Schmidt number, the ratio of desorbed water vapor mass to fibrous absorbent mass, the nondimensional temperature and the ratio of vessel length to fiber diameter. Fourier number for the nondimensional temperature and the ratio of desorbed water vapor mass to fibrous adsorbent mass, the nondimensional temperature and the ratio of vessel length to fiber diameter. (author)

  4. Size matters: Associations between the androgen receptor CAG repeat length and the intrafollicular hormone milieu

    DEFF Research Database (Denmark)

    Borgbo, T; Macek, M; Chrudimska, J

    2015-01-01

    Granulosa cell (GC) expressed androgen receptors (AR) and intrafollicular androgens are central to fertility. The transactivating domain of the AR contains a polymorphic CAG repeat sequence, which is linked to the transcriptional activity of AR and may influence the GC function. This study aims...... to evaluate the effects of the AR CAG repeat length on the intrafollicular hormone profiles, and the gene expression profiles of GC from human small antral follicles. In total, 190 small antral follicles (3-11 mm in diameter) were collected from 58 women undergoing ovarian cryopreservation for fertility...... expression compared to medium CAG repeat lengths (P = 0.03). In conclusion, long CAG repeat lengths in the AR were associated to significant attenuated levels of androgens and an increased conversion of testosterone into oestradiol, in human small antral follicles....

  5. Magnetorheology of submicron diameter iron microwires dispersed in silicone oil

    International Nuclear Information System (INIS)

    Bell, R C; Karli, J O; Vavreck, A N; Zimmerman, D T; Ngatu, G T; Wereley, N M

    2008-01-01

    We investigate the magnetorheological (MR) properties of suspensions containing iron microwires with 260 nm diameter and two distinct length distributions of 5.4 ± 5.2 µm and 7.6 ± 5.1 µm suspended in silicone oil (0.45 Pa s). The rheological properties of these fluids were determined using a parallel plate rheometer equipped with a variable strength electromagnet. The shear stress was measured as a function of shear rate for increasing applied magnetic fields. These results were modeled using the Bingham-plastic constitutive model to determine the apparent yield stress and viscosity as a function of increasing volume fraction and length of microwires. At a saturated magnetic flux density, the yield stress using the 5.4 µm microwires was found to be 0.65, 2.23, and 4.76 kPa for the 2, 4, and 6 vol% suspensions, respectively. For the 7.6 µm wires, the yield stress increases to 8.2 kPa for the 6 vol% suspension. Compared with conventional MR fluids employing spherical particles, the degree of settling is markedly decreased in the microwire-based fluids. At 6 vol%, conventional fluids display appreciable settling whereas the microwire-based fluids display no discernable settling. Moreover, the rod-shaped microwires are shown to increase the yield stress of the fluids and enhance the MR performance

  6. Link lengths and their growth powers

    International Nuclear Information System (INIS)

    Huh, Youngsik; No, Sungjong; Oh, Seungsang; Rawdon, Eric J

    2015-01-01

    For a certain infinite family F of knots or links, we study the growth power ratios of their stick number, lattice stick number, minimum lattice length and minimum ropelength compared with their minimum crossing number c(K) for every K∈F. It is known that the stick number and lattice stick number grow between the (1/2) and linear power of the crossing number, and minimum lattice length and minimum ropelength grow with at least the (3/4) power of crossing number (which is called the four-thirds power law). Furthermore, the minimal lattice length and minimum ropelength grow at most as O (c(K)[ln(c(K))] 5 ), but it is unknown whether any family exhibits superlinear growth. For any real number r between (1/2) and 1, we give an infinite family of non-splittable prime links in which the stick number and lattice stick number grow exactly as the rth power of crossing number. Furthermore for any real number r between (3/4) and 1, we give another infinite family of non-splittable prime links in which the minimum lattice length and minimum ropelength grow exactly as the rth power of crossing number. (paper)

  7. Arcjet nozzle area ratio effects

    Science.gov (United States)

    Curran, Francis M.; Sarmiento, Charles J.; Birkner, Bjorn W.; Kwasny, James

    1990-01-01

    An experimental investigation was conducted to determine the effect of nozzle area ratio on the operating characteristics and performance of a low power dc arcjet thruster. Conical thoriated tungsten nozzle inserts were tested in a modular laboratory arcjet thruster run on hydrogen/nitrogen mixtures simulating the decomposition products of hydrazine. The converging and diverging sides of the inserts had half angles of 30 and 20 degrees, respectively, similar to a flight type unit currently under development. The length of the diverging side was varied to change the area ratio. The nozzle inserts were run over a wide range of specific power. Current, voltage, mass flow rate, and thrust were monitored to provide accurate comparisons between tests. While small differences in performance were observed between the two nozzle inserts, it was determined that for each nozzle insert, arcjet performance improved with increasing nozzle area ratio to the highest area ratio tested and that the losses become very pronounced for area ratios below 50. These trends are somewhat different than those obtained in previous experimental and analytical studies of low Re number nozzles. It appears that arcjet performance can be enhanced via area ratio optimization.

  8. Arcjet Nozzle Area Ratio Effects

    Science.gov (United States)

    Curran, Francis M.; Sarmiento, Charles J.; Birkner, Bjorn W.; Kwasny, James

    1990-01-01

    An experimental investigation was conducted to determine the effect of nozzle area ratio on the operating characteristics and performance of a low power dc arcjet thruster. Conical thoriated tungsten nozzle inserts were tested in a modular laboratory arcjet thruster run on hydrogen/nitrogen mixtures simulating the decomposition products of hydrazine. The converging and diverging sides of the inserts had half angles of 30 and 20 degrees, respectively, similar to a flight type unit currently under development. The length of the diverging side was varied to change the area ratio. The nozzle inserts were run over a wide range of specific power. Current, voltage, mass flow rate, and thrust were monitored to provide accurate comparisons between tests. While small differences in performance were observed between the two nozzle inserts, it was determined that for each nozzle insert, arcjet performance improved with increasing nozzle area ratio to the highest area ratio tested and that the losses become very pronounced for area ratios below 50. These trends are somewhat different than those obtained in previous experimental and analytical studies of low Re number nozzles. It appears that arcjet performance can be enhanced via area ratio optimization.

  9. Fabrication of an Optical Fiber Micro-Sphere with a Diameter of Several Tens of Micrometers.

    Science.gov (United States)

    Yu, Huijuan; Huang, Qiangxian; Zhao, Jian

    2014-06-25

    A new method to fabricate an integrated optical fiber micro-sphere with a diameter within 100 µm, based on the optical fiber tapering technique and the Taguchi method is proposed. Using a 125 µm diameter single-mode (SM) optical fiber, an optical fiber taper with a cone angle is formed with the tapering technique, and the fabrication optimization of a micro-sphere with a diameter of less than 100 µm is achieved using the Taguchi method. The optimum combination of process factors levels is obtained, and the signal-to-noise ratio (SNR) of three quality evaluation parameters and the significance of each process factors influencing them are selected as the two standards. Using the minimum zone method (MZM) to evaluate the quality of the fabricated optical fiber micro-sphere, a three-dimensional (3D) numerical fitting image of its surface profile and the true sphericity are subsequently realized. From the results, an optical fiber micro-sphere with a two-dimensional (2D) diameter less than 80 µm, 2D roundness error less than 0.70 µm, 2D offset distance between the micro-sphere center and the fiber stylus central line less than 0.65 µm, and true sphericity of about 0.5 µm, is fabricated.

  10. Fabrication of an Optical Fiber Micro-Sphere with a Diameter of Several Tens of Micrometers

    Directory of Open Access Journals (Sweden)

    Huijuan Yu

    2014-06-01

    Full Text Available A new method to fabricate an integrated optical fiber micro-sphere with a diameter within 100 µm, based on the optical fiber tapering technique and the Taguchi method is proposed. Using a 125 µm diameter single-mode (SM optical fiber, an optical fiber taper with a cone angle is formed with the tapering technique, and the fabrication optimization of a micro-sphere with a diameter of less than 100 µm is achieved using the Taguchi method. The optimum combination of process factors levels is obtained, and the signal-to-noise ratio (SNR of three quality evaluation parameters and the significance of each process factors influencing them are selected as the two standards. Using the minimum zone method (MZM to evaluate the quality of the fabricated optical fiber micro-sphere, a three-dimensional (3D numerical fitting image of its surface profile and the true sphericity are subsequently realized. From the results, an optical fiber micro-sphere with a two-dimensional (2D diameter less than 80 µm, 2D roundness error less than 0.70 µm, 2D offset distance between the micro-sphere center and the fiber stylus central line less than 0.65 µm, and true sphericity of about 0.5 µm, is fabricated.

  11. PREDICTIVE ACCURACY OF TRANSCEREBELLAR DIAMETER IN COMPARISON WITH OTHER FOETAL BIOMETRIC PARAMETERS FOR GESTATIONAL AGE ESTIMATION AMONG PREGNANT NIGERIAN WOMEN.

    Science.gov (United States)

    Adeyekun, A A; Orji, M O

    2014-04-01

    To compare the predictive accuracy of foetal trans-cerebellar diameter (TCD) with those of other biometric parameters in the estimation of gestational age (GA). A cross-sectional study. The University of Benin Teaching Hospital, Nigeria. Four hundred and fifty healthy singleton pregnant women, between 14-42 weeks gestation. Trans-cerebellar diameter (TCD), biparietal diameter (BPD), femur length (FL), abdominal circumference (AC) values across the gestational age range studied. Correlation and predictive values of TCD compared to those of other biometric parameters. The range of values for TCD was 11.9 - 59.7mm (mean = 34.2 ± 14.1mm). TCD correlated more significantly with menstrual age compared with other biometric parameters (r = 0.984, p = 0.000). TCD had a higher predictive accuracy of 96.9% ± 12 days), BPD (93.8% ± 14.1 days). AC (92.7% ± 15.3 days). TCD has a stronger predictive accuracy for gestational age compared to other routinely used foetal biometric parameters among Nigerian Africans.

  12. Frequency of postnatal hydronephrosis in infants with a renal anterior-posterior pelvic diameter > 4 mm on midtrimester ultrasound.

    Science.gov (United States)

    Chou, Ching-Yu; Chen, Li-Ching; Cheong, Mei-Leng; Tsai, Ming-Song

    2015-10-01

    To examine the association of antenatal renal pelvic dilatation observed on midtrimester ultrasound screening with the presence of hydronephrosis in newborn infants. The records of patients who received fetal ultrasound examination at 18-28 weeks' gestation from May 2008 to March 2012 were retrospectively reviewed. A fetal renal pelvic anterior-posterior (AP) diameter > 4 mm was considered abnormal and ≤ 4 mm was considered normal. On postnatal ultrasound, a renal pelvic AP diameter > 3 mm was considered to indicate hydronephrosis and ≤ 3 mm was considered normal. The association of postnatal hydronephrosis with prenatal pelvic AP diameter was determined using binary logistic regression analysis. The study comprised 1310 newborn infants: 684 (52.2%) male and 626 (47.8%) female. Multivariate analysis showed a right or left prenatal AP renal pelvic diameter > 4 mm was associated with a higher risk of postnatal hydronephrosis compared with a right and left prenatal AP renal pelvic diameter ≤ 4 mm. Boys had a higher risk for postnatal hydronephrosis than girls (odds ratio = 2.42, p 4 mm on midtrimester ultrasound is predictive of postnatal hydronephrosis. Copyright © 2015. Published by Elsevier B.V.

  13. Displacement-length ratios and contractional strains of lunar wrinkle ridges in Mare Serenitatis and Mare Tranquillitatis

    Science.gov (United States)

    Li, Bo; Ling, Zongcheng; Zhang, Jiang; Chen, Jian; Ni, Yuheng; Liu, Chunli

    2018-04-01

    Wrinkle ridges are complex thrust faults commonly found in lunar mare basalts and caused by compressional stresses from both local basin and global Moon. In this paper, we select 59 single wrinkle ridges in Mare Serenitatis and 39 single wrinkle ridges in Mare Tranquillitatis according to WAC mosaic image. For each wrinkle ridge, several topographic profiles near its midpoint are generated to measure its height and maximum displacement (Dmax) through LOLA DEM data. Then we make 2D plots of displacement-length (L) for ridge population in the two maria. The Dmax-L ratios (γ) are derived by a linear fit method according to the D-L data. The γ value (2.13 × 10-2) of ridges in Mare Tranquillitatis is higher than the γ value (1.73 × 10-2) of ridges in Mare Serenitatis. In the last, the contractional strains (ε) in Mare Serenitatis and Mare Tranquillitatis are estimated to be ∼0.36% and 0.14% (assuming the fault plane dip θ is 25°). The values of the free-air gravity anomalies in Mare Serenitatis range from 78 to 358 mGal higher than those of the gravity anomalies in Mare Tranquillitatis which range from -70 to 120 mGal. The average thickness of basalts in Mare Tranquillitatis is 400 m, while that of basalts in Mare Serenitatis is 798 m. Moreover, the average age for ridge group in Mare Serenitatis is bigger than the wrinkle ridge's age in Mare Tranquillitatis. The formation of ridge group in Mare Serenitatis takes longer time than that in Mare Serenitatis. Therefore, we think the higher value of gravity anomalies, thicker basaltic units and longer formation time for wrinkle ridge in Mare Serenitatis maybe result in the higher value of contractional strain, although the formation of Tranquillitatis basin is earlier than that of Serenitatis basin.

  14. Fundamental length and relativistic length

    International Nuclear Information System (INIS)

    Strel'tsov, V.N.

    1988-01-01

    It si noted that the introduction of fundamental length contradicts the conventional representations concerning the contraction of the longitudinal size of fast-moving objects. The use of the concept of relativistic length and the following ''elongation formula'' permits one to solve this problem

  15. Measurement of laminar burning velocities and Markstein lengths of diluted hydrogen-enriched natural gas

    Energy Technology Data Exchange (ETDEWEB)

    Miao, Haiyan; Jiao, Qi; Huang, Zuohua; Jiang, Deming [State Key Laboratory of Multiphase Flow in Power Engineering, School of Energy and Power Eng., Xi' an Jiaotong University (China)

    2009-01-15

    The laminar flame characteristics of natural gas-hydrogen-air-diluent gas (nitrogen/CO{sub 2}) mixtures were studied in a constant volume combustion bomb at various diluent ratios, hydrogen fractions and equivalence ratios. Both unstretched laminar burning velocity and Markstein length were obtained. The results showed that hydrogen fraction, diluent ratio and equivalence ratio have combined influence on laminar burning velocity and flame instability. The unstretched laminar burning velocity is reduced at a rate that is increased with the increase of the diluent ratio. The reduction effect of CO{sub 2} diluent gas is stronger than that of nitrogen diluent gas. Hydrogen-enriched natural gas with high hydrogen fraction can tolerate more diluent gas than that with low hydrogen fraction. Markstein length can either increase or decrease with the increase of the diluent ratio, depending on the hydrogen fraction of the fuel. (author)

  16. Role of VI/II ratio on the growth of ZnO nanostructures using chemical bath deposition

    Energy Technology Data Exchange (ETDEWEB)

    Urgessa, Z.N., E-mail: zelalem.urgessa@nmmu.ac.za [Department of Physics, P.O. Box 77000, Nelson Mandela Metropolitan University, Port Elizabeth 6031 (South Africa); Oluwafemi, O.S. [Department of Chemistry and Chemical Technology, Walter Sisulu University, Mthatha Campus, Private Bag XI, 5117 (South Africa); Botha, J.R. [Department of Physics, P.O. Box 77000, Nelson Mandela Metropolitan University, Port Elizabeth 6031 (South Africa)

    2012-05-15

    In this paper the growth process and morphological evolution of ZnO nanostructures were investigated in a series of experiments using chemical bath deposition. The experimental results indicate that the morphological evolution depends on the reaction conditions, particularly on OH{sup -} to Zn{sup 2+} ratio (which directly affects the pH). For low VI/II ratios, quasi-spherical nanoparticles of an average diameter 30 nm are obtained, whereas for larger VI/II ratios, nanorods with an average diameter less than 100 nm are produced, which indicates that by systematically controlling the VI/II ratio, it is possible to produce different shapes and sizes of ZnO nanostructures. A possible mechanism for the nanostructural change of the as-synthesized ZnO from particle to rod was elucidated based on the relative densities of H{sup +} and OH{sup -} in the solution.

  17. Role of VI/II ratio on the growth of ZnO nanostructures using chemical bath deposition

    International Nuclear Information System (INIS)

    Urgessa, Z.N.; Oluwafemi, O.S.; Botha, J.R.

    2012-01-01

    In this paper the growth process and morphological evolution of ZnO nanostructures were investigated in a series of experiments using chemical bath deposition. The experimental results indicate that the morphological evolution depends on the reaction conditions, particularly on OH − to Zn 2+ ratio (which directly affects the pH). For low VI/II ratios, quasi-spherical nanoparticles of an average diameter 30 nm are obtained, whereas for larger VI/II ratios, nanorods with an average diameter less than 100 nm are produced, which indicates that by systematically controlling the VI/II ratio, it is possible to produce different shapes and sizes of ZnO nanostructures. A possible mechanism for the nanostructural change of the as-synthesized ZnO from particle to rod was elucidated based on the relative densities of H + and OH − in the solution.

  18. Analysis of the radius and diameter protocols in terms of pricing telecommunication services

    Directory of Open Access Journals (Sweden)

    Vesna M. Radonjić

    2013-06-01

    client and the server, depending on the current needs of the network. At the transport layer, Diameter uses the TCP or SCTP protocols. When compared to UDP, these protocols provide reliable transmission which is very important for applications exchanging data related to accounting. In addition, the Diameter protocol allows the transmission of accounting information in real time and it incorporates several methods for troubleshooting in order to minimize the loss of accounting data when a failure occurs, which is not the case with RADIUS. Given the present benefits, introduced improvements, flexibility, expandability, IETF and 3GPP's support and the support of big companies, there is a great chance that Diameter will replace RADIUS.   Conclusion   This paper presents a general overview of the RADIUS and Diameter protocols, including some of their basic operations with a special emphasis on accounting applications. The similarities of these protocols are reflected in the support of the same functions in a similar format of the packages. The differences are related to the protocol architectures and the methods of determining authentication, authorization and accounting mechanisms. Regarding accounting aspects, the most important advantages of the Diameter protocol are its possibility to transmit accounting information in real time and implemented mechanisms for troubleshooting in order to minimize the loss of accounting data in case of failure. Owing to to these characteristics, the Diameter protocol achieves a significant advantage over RADIUS in next generation networks.

  19. Tracheomalacia Treatment Using a Large-Diameter, Custom-Made Airway Stent in a Case with Mounier-Kuhn Syndrome

    OpenAIRE

    Özdemir, Cengiz; Sökücü, Sinem Nedime; Karasulu, Levent; Altın, Sedat; Dalar, Levent

    2014-01-01

    Mounier-Kuhn Syndrome (MKS) is a rare congenital disease that presents with abnormal enlargement in the central airways. In MKS, tracheomegaly is accompanied by difficulty in expelling recurrent lung infections and bronchiectasia. We presented a patient with MKS where commercially made stents were inadequate for stabilization and a custom-made, self-expandable metallic stent with a diameter of 28 mm and length of 100 mm was used. Chest pain that was thought to develop due to the stent and tha...

  20. An experimental study on the effects of swirling oxidizer flow and diameter of fuel nozzle on behaviour and light emittance of propane-oxygen non-premixed flame

    Directory of Open Access Journals (Sweden)

    Javareshkian Alireza

    2017-01-01

    Full Text Available In this study, the stability and the light emittance of non-premixed propane-oxygen flames have been experimentally evaluated with respect to swirling oxidizer flow and variations in fuel nozzle diameter. Hence, three types of the vanes with the swirl angles of 30°, 45°, and 60° have been chosen for producing the desired swirling flows. The main aims of this study are to determine the flame behaviour, light emittance, and also considering the effect of variation in fuel nozzle diameter on combustion phenomena such as flame length, flame shape, and soot free length parameter. The investigation into the flame phenomenology was comprised of variations of the oxidizer and fuel flow velocities (respective Reynolds numbers and the fuel nozzle diameter. The results showed that the swirl effect could change the flame luminosity and this way could reduce or increase the maximum value of the flame light emittance in the combustion zone. Therefore, investigation into the flame light emittance can give a good clue for studying the mixing quality of reactants, the flame phenomenology (blue flame or sooty flame, localized extinction, and the combustion intensity in non-premixed flames.

  1. The thermal properties of controllable diameter carbon nanotubes synthesized by using AB5 alloy of micrometer magnitude as catalyst

    International Nuclear Information System (INIS)

    Zhang Haiyan; Chen Yiming; Zeng Guoxun; Huang Huiping; Xie Zhiwei; Jie Xiaohua

    2007-01-01

    We have synthesized multi-wall carbon nanotubes by catalytic chemical vapour deposition (CCVD) method using an AB 5 hydrogen storage alloy with diameter ranging from 38 to 150 μm as a catalyst. The H 2 uptake capacity of the carbon nanotubes prepared using an AB 5 alloy as a catalyst is about 4 wt.% through to the pressure of 8 MPa at room temperature. Differential thermal analysis-thermogravimetric analysis (DTA-TGA) technique has been applied to investigate the effect of the diameters of the AB 5 alloy catalyst of micrometer magnitude and the technique conditions in the CCVD process on the thermal properties of carbon nanotubes. As the catalyst diameter increases from 38 to 150 μm, the average diameter of the prepared carbon nanotubes increases and the diameter distribution also enlarges. Electron microscope, Raman spectrum and thermal analysis all indicated that the catalyst sizes affect the diameter and the thermal properties of the carbon nanotubes. When the catalyst diameter increases, the initial weight loss temperature and the differential thermal peak temperature of the carbon nanotubes increases, which shows that the lager the diameter of the carbon nanotubes is, the higher the oxidation temperature, and the better the anti-oxidizablity. However, if the diameter of the catalyst is larger than 100 μm, the anti-oxidizablity does not rise anymore but tend to be invariableness. In the CCVD preparation process, the anti-oxidizability of the carbon nanotubes increases, when raising the ratio of the hydrogen gas in the reaction gas in our experimental range (4:1, 3:1, and 2:1, respectively)

  2. Database and prediction model for CANDU pressure tube diameter

    Energy Technology Data Exchange (ETDEWEB)

    Jung, J.Y.; Park, J.H. [Korea Atomic Energy Research Inst., Daejeon (Korea, Republic of)

    2014-07-01

    The pressure tube (PT) diameter is basic data in evaluating the CCP (critical channel power) of a CANDU reactor. Since the CCP affects the operational margin directly, an accurate prediction of the PT diameter is important to assess the operational margin. However, the PT diameter increases by creep owing to the effects of irradiation by neutron flux, stress, and reactor operating temperatures during the plant service period. Thus, it has been necessary to collect the measured data of the PT diameter and establish a database (DB) and develop a prediction model of PT diameter. Accordingly, in this study, a DB for the measured PT diameter data was established and a neural network (NN) based diameter prediction model was developed. The established DB included not only the measured diameter data but also operating conditions such as the temperature, pressure, flux, and effective full power date. The currently developed NN based diameter prediction model considers only extrinsic variables such as the operating conditions, and will be enhanced to consider the effect of intrinsic variables such as the micro-structure of the PT material. (author)

  3. The Torg-Pavlov ratio for the prediction of acute spinal cord injury after a minor trauma to the cervical spine.

    Science.gov (United States)

    Aebli, Nikolaus; Wicki, Anina G; Rüegg, Tabea B; Petrou, Nassos; Eisenlohr, Heidrun; Krebs, Jörg

    2013-06-01

    Acute cervical spinal cord injury (SCI) has been observed in some patients after a minor trauma to the cervical spine. The discrepancy between the severity of the trauma and the clinical symptoms has been attributed to spinal canal stenosis. However, to date, there is no universally established radiological parameter for identifying critical spinal stenosis in these patients. The spinal canal-to-vertebral body ratio (Torg-Pavlov ratio) has been proposed for assessing developmental spinal canal stenosis. The relevance of the Torg-Pavlov ratio for predicting the occurrence and severity of acute cervical SCI after a minor trauma to the cervical spine has not yet been established. To investigate the Torg-Pavlov ratio values of the cervical spine in patients suffering from acute cervical SCI after a minor trauma to the cervical spine and the use of the Torg-Pavlov ratio for identifying patients at risk of cervical SCI and predicting the severity and course of symptoms. Retrospective radiological study of consecutive patients. Forty-five patients suffering from acute cervical SCI and 68 patients showing no neurologic symptoms after a minor trauma to the cervical spine. Midvertebral sagittal cervical spinal canal diameter and the sagittal vertebral body diameter. Calculation of the Torg-Pavlov ratio values. Conventional lateral radiographs of the cervical spine (C3-C7) were analyzed to determine the Torg-Pavlov ratio values. Receiver operating characteristic curves were calculated for evaluating the classification accuracy of the Torg-Pavlov ratio for predicting SCI. The Torg-Pavlov ratio values in the SCI group were significantly (pPavlov ratio cutoff value of 0.7 yielded the greatest positive likelihood ratio for predicting the occurrence of SCI. However, there were no significant differences in the Torg-Pavlov ratio values between the different American Spinal Injury Association Impairment Score groups and between patients with complete, partial, and no recovery of

  4. Application of the Critical Heat Flux Look-Up Table to Large Diameter Tubes

    Directory of Open Access Journals (Sweden)

    M. El Nakla

    2013-01-01

    Full Text Available The critical heat flux look-up table was applied to a large diameter tube, namely 67 mm inside diameter tube, to predict the occurrence of the phenomenon for both vertical and horizontal uniformly heated tubes. Water was considered as coolant. For the vertical tube, a diameter correction factor was directly applied to the 1995 critical heat flux look-up table. To predict the occurrence of critical heat flux in horizontal tube, an extra correction factor to account for flow stratification was applied. Both derived tables were used to predict the effect of high heat flux and tube blockage on critical heat flux occurrence in boiler tubes. Moreover, the horizontal tube look-up table was used to predict the safety limits of the operation of boiler for 50% allowable heat flux.

  5. Diameter effect on critical heat flux

    International Nuclear Information System (INIS)

    Tanase, A.; Cheng, S.C.; Groeneveld, D.C.; Shan, J.Q.

    2009-01-01

    The critical heat flux look-up table (CHF LUT) is widely used to predict CHF for various applications, including design and safety analysis of nuclear reactors. Using the CHF LUT for round tubes having inside diameters different from the reference 8 mm involves conversion of CHF to 8 mm. Different authors [Becker, K.M., 1965. An Analytical and Experimental Study of Burnout Conditions in Vertical Round Ducts, Aktiebolaget Atomenergie Report AE 177, Sweden; Boltenko, E.A., et al., 1989. Effect of tube diameter on CHF at various two phase flow regimes, Report IPE-1989; Biasi, L., Clerici, G.C., Garriba, S., Sala, R., Tozzi, A., 1967. Studies on Burnout, Part 3, Energia Nucleare, vol. 14, pp. 530-536; Groeneveld, D.C., Cheng, S.C., Doan, T., 1986. AECL-UO critical heat flux look-up table. Heat Transfer Eng., 7, 46-62; Groeneveld et al., 1996; Hall, D.D., Mudawar, I., 2000. Critical heat flux for water flow in tubes - II subcooled CHF correlations. Int. J. Heat Mass Transfer, 43, 2605-2640; Wong, W.C., 1996. Effect of tube diameter on critical heat flux, MaSC dissertation, Ottawa Carleton Institute for Mechanical and Aeronautical Engineering, University of Ottawa] have proposed several types of correlations or factors to describe the diameter effect on CHF. The present work describes the derivation of new diameter correction factor and compares it with several existing prediction methods

  6. Age, growth and length-weight relationship of the white skate, Rostroraja alba (Linnaeus, 1758 (Chondrichthyans: Rajidae, from the Gulf of Gabes (Tunisia, Central Mediterranean

    Directory of Open Access Journals (Sweden)

    Hasna Kadri

    2014-06-01

    Full Text Available Objective: To investigate the length distribution, sex ratio, length-weight relationship, age and growth of Rostroraja alba in the Gulf of Gabes. Methods: This study estimated age and growth of the white skate, Rostroraja alba by counting vertebral band pairs from 112 specimens taken by commercial fisheries during 2006-2009 from the Gulf of Gabes (Southern Tunisia, Central Mediterranean Sea. Results: This is the first and only known information in regards to the age and growth of this species in Tunisia. Vertebra diameter was strongly correlated with total length and age, which were expressed by linear or cubic regression equations. The oldest female in this study was 35 years and 160 cm, whereas the oldest male was 32 years and 150 cm. The von Bertalanffy growth parameters were TL∞=(202.26±3.40 cm, K=(0.040±0.038/year and t0=(1.84±0.01 10 -1 /year for females and TL∞=(198.60±3.61 cm, K=(0.060±0.076/year and t0=(1.28±0.04/year for males. Conclusions: This study would be an effective tool for fishery biologists, managers and conservationists to initiate management strategies and regulations for the sustainable conservation of the remaining stocks of this species in the Gulf of Gabes (Southern Tunisia ecosystem

  7. Optic nerve sheath diameter: A novel way to monitor the brain

    Directory of Open Access Journals (Sweden)

    Seelora Sahu

    2017-01-01

    Full Text Available Measurement and monitoring of intracranial pressure is pivotal in management of brain injured patients. As a rapid and easily done bed side measurement, ultrasonography of the optic nerve sheath diameter presents itself as a possible replacement of the conventional invasive methods of intracranial pressure management. In this review we go through the evolution of optic nerve sheath diameter measurement as a novel marker of predicting raised intracranial pressure, the modalities by which it can be measured as well as its correlation with the invasive methods of intracranial pressure monitoring.

  8. Lysosome Transport as a Function of Lysosome Diameter

    Science.gov (United States)

    Bandyopadhyay, Debjyoti; Cyphersmith, Austin; Zapata, Jairo A.; Kim, Y. Joseph; Payne, Christine K.

    2014-01-01

    Lysosomes are membrane-bound organelles responsible for the transport and degradation of intracellular and extracellular cargo. The intracellular motion of lysosomes is both diffusive and active, mediated by motor proteins moving lysosomes along microtubules. We sought to determine how lysosome diameter influences lysosome transport. We used osmotic swelling to double the diameter of lysosomes, creating a population of enlarged lysosomes. This allowed us to directly examine the intracellular transport of the same organelle as a function of diameter. Lysosome transport was measured using live cell fluorescence microscopy and single particle tracking. We find, as expected, the diffusive component of intracellular transport is decreased proportional to the increased lysosome diameter. Active transport of the enlarged lysosomes is not affected by the increased lysosome diameter. PMID:24497985

  9. Emphasis: an active management model

    International Nuclear Information System (INIS)

    Gray, L.M.

    1983-01-01

    The Institute of Nuclear Materials Management was founded and has grown on the basis of promoting professionalism in the nuclear industry. This paper is concerned with professional management of nuclear material. The paper introduces the reader to Emphasis, an active management model. The management model provides the framework to assist a manager in directing his available resources. Emphasis provides for establishing goals, identifying and selecting objectives, matching objectives to specific personnel, preparing and monitoring action plans, and evaluating results. The model stresses crisis prevention by systematically administering and controlling resources. A critical requirement for implementation of the model is the desire to manage, to be in charge of the situation. The nuclear industry does need managers - people who realize the sensitive nature of the industry, professionals who insist on improved performance

  10. Evaluation of the Normal Fetal Kidney Length and Its Correlation with Gestational Age

    Directory of Open Access Journals (Sweden)

    Farrokh Seilanian Toosi

    2013-05-01

    Full Text Available A true estimation of gestational age (GA plays an important role in quality maternity care and scheduling the labor date. This study aimed to evaluate the normal fetal kidney length (KL and its correlation with GA. A cross-sectional study on 92 pregnant women between 8th and 10th week of gestation with normal singleton pregnancy underwent standard ultrasound fetal biometry and kidney length measurement. univariate and multivariate linear regression analysis was used to create a predictive equation to estimate GA on the KL and fetobiometry parameters. A significant correlation was found between GA and KL (r=0.83, P<0.002. The best GA predictor was obtained by combining head circumference, fetal biparietal diameter, femur length and KL with a standard error (SE about 14.2 days. Our findings showed that KL measurements combination with other fetal biometric parameters could predict age of pregnancy with a better precision.

  11. Individual stem value recovery of modified and conventional tree-length systems in the southeastern United States

    Science.gov (United States)

    Amanda H. Lang; Shawn A. Baker; W. Dale Greene; Glen E. Murphy

    2010-01-01

    We compared value recovery of a modified treelength (MTL) logging system that measures product diameter and length using a Waratah 626 harvester head to that of a treelength (TL) system that estimates dimensions. A field test compared the actual value cut to the maximum potential value suggested by the log bucking optimization program Assessment of Value by Individual...

  12. Reduction of single-walled carbon nanotube diameter to sub-nm via feedstock

    Energy Technology Data Exchange (ETDEWEB)

    Thurakitseree, T.; Zhao, Pei; Chiashi, Shohei; Maruyama, Shigeo [Department of Mechanical Engineering, University of Tokyo (Japan); Kramberger, Christian [Faculty of Physics, University of Vienna (Austria); Einarsson, Erik [Department of Mechanical Engineering, University of Tokyo (Japan); Global Center of Excellence for Mechanical Systems Innovation, University of Tokyo (Japan)

    2012-12-15

    Vertically aligned single-walled carbon nanotube arrays were synthesized from dip-coated binary Co/Mo catalyst by no-flow chemical vapor deposition (CVD) from either pure ethanol or acetonitrile as carbon feedstock. By changing to acetonitrile the mean diameter was reduced from 2.1 nm to less than 1.0 nm despite using identically prepared catalyst. The demonstrated diameter control on flat substrates is a versatile approach towards the direct synthesis of tailored single-walled carbon nanotubes. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  13. Crack initiation and propagation paths in small diameter FSW 6082-T6 aluminium tubes under fatigue loading

    Directory of Open Access Journals (Sweden)

    Roberto Tovo

    2016-03-01

    Full Text Available This paper reports results of fatigue tests of friction stir welded (FSW aluminium tubes. Relatively small 38 mm diameter tubes were used and hence an automated FSW process using a retracting tool was designed for this project, as the wall thickness of the aluminium tube was similar to the diameter of the FSW tool. This is a more complex joint geometry to weld than the more usual larger diameter tube reported in the literature. S-N fatigue testing was performed using load ratios of R = 0.1 and R = -1. Crack path analysis was performed using both low magnification stereo microscopy and scanning electron microscopy, in order to identify crack initiation sites and to determine the direction of crack propagation. Work is still in progress to follow the crack path through the various microstructural zones associated with the weld. A simple statistical analysis was used to characterize the most typical crack initiation site. This work forms part of a wider project directed at determining multiaxial fatigue design rules for small diameter 6082-T6 aluminium tubes that could be of use in the ground vehicle industry.

  14. Development of the Heated Length Correction Factor

    International Nuclear Information System (INIS)

    Park, Ho-Young; Kim, Kang-Hoon; Nahm, Kee-Yil; Jung, Yil-Sup; Park, Eung-Jun

    2008-01-01

    The Critical Heat Flux (CHF) on a nuclear fuel is defined by the function of flow channel geometry and flow condition. According to the selection of the explanatory variable, there are three hypotheses to explain CHF at uniformly heated vertical rod (inlet condition hypothesis, exit condition hypothesis, local condition hypothesis). For inlet condition hypothesis, CHF is characterized by function of system pressure, rod diameter, rod length, mass flow and inlet subcooling. For exit condition hypothesis, exit quality substitutes for inlet subcooling. Generally the heated length effect on CHF in exit condition hypothesis is smaller than that of other variables. Heated length is usually excluded in local condition hypothesis to describe the CHF with only local fluid conditions. Most of commercial plants currently use the empirical CHF correlation based on local condition hypothesis. Empirical CHF correlation is developed by the method of fitting the selected sensitive local variables to CHF test data using the multiple non-linear regression. Because this kind of method can not explain physical meaning, it is difficult to reflect the proper effect of complex geometry. So the recent CHF correlation development strategy of nuclear fuel vendor is making the basic CHF correlation which consists of basic flow variables (local fluid conditions) at first, and then the geometrical correction factors are compensated additionally. Because the functional forms of correction factors are determined from the independent test data which represent the corresponding geometry separately, it can be applied to other CHF correlation directly only with minor coefficient modification

  15. Migration of carbon nanotubes from liquid phase to vapor phase in the refrigerant-based nanofluid pool boiling

    Directory of Open Access Journals (Sweden)

    Peng Hao

    2011-01-01

    Full Text Available Abstract The migration characteristics of carbon nanotubes from liquid phase to vapor phase in the refrigerant-based nanofluid pool boiling were investigated experimentally. Four types of carbon nanotubes with the outside diameters from 15 to 80 nm and the lengths from 1.5 to 10 μm were used in the experiments. The refrigerants include R113, R141b and n-pentane. The oil concentration is from 0 to 10 wt.%, the heat flux is from 10 to 100 kW·m-2, and the initial liquid-level height is from 1.3 to 3.4 cm. The experimental results indicate that the migration ratio of carbon nanotube increases with the increase of the outside diameter or the length of carbon nanotube. For the fixed type of carbon nanotube, the migration ratio decreases with the increase of the oil concentration or the heat flux, and increases with the increase of the initial liquid-level height. The migration ratio of carbon nanotube increases with the decrease of dynamic viscosity of refrigerant or the increase of liquid phase density of refrigerant. A model for predicting the migration ratio of carbon nanotubes in the refrigerant-based nanofluid pool boiling is proposed, and the predictions agree with 92% of the experimental data within a deviation of ±20%.

  16. Telomere length and long-term endurance exercise: does exercise training affect biological age? A pilot study.

    Directory of Open Access Journals (Sweden)

    Ida Beate Ø Østhus

    Full Text Available BACKGROUND: Telomeres are potential markers of mitotic cellular age and are associated with physical ageing process. Long-term endurance training and higher aerobic exercise capacity (VO(2max are associated with improved survival, and dynamic effects of exercise are evident with ageing. However, the association of telomere length with exercise training and VO(2max has so far been inconsistent. Our aim was to assess whether muscle telomere length is associated with endurance exercise training and VO(2max in younger and older people. METHODS: Twenty men; 10 young (22-27 years and 10 old (66-77 years, were studied in this cross-sectional study. Five out of 10 young adults and 5 out of 10 older were endurance athletes, while other halves were exercising at a medium level of activity. Mean telomere length was measured as telomere/single copy gene-ratio (T/S-ratio using quantitative real time polymerase chain reaction. VO(2max was measured directly running on a treadmill. RESULTS: Older endurance trained athletes had longer telomere length compared with older people with medium activity levels (T/S ratio 1.12±0.1 vs. 0.92±0.2, p = 0.04. Telomere length of young endurance trained athletes was not different than young non-athletes (1.47±0.2 vs. 1.33±0.1, p = 0.12. Overall, there was a positive association between T/S ratio and VO(2max (r = 0.70, p = 0.001. Among endurance trained athletes, we found a strong correlation between VO(2max and T/S ratio (r = 0.78, p = 0.02. However, corresponding association among non-athlete participants was relatively weak (r = 0.58, p = 0.09. CONCLUSION: Our data suggest that VO(2max is positively associated with telomere length, and we found that long-term endurance exercise training may provide a protective effect on muscle telomere length in older people.

  17. Human permanent teeth are divided into two parts at the cemento-enamel junction in the divine golden ratio.

    Science.gov (United States)

    Anand, Rahul; Sarode, Sachin C; Sarode, Gargi S; Patil, Shankargouda

    2017-01-01

    The aim of this study is to find out whether tooth length (crown length + root length) follows the rule of most divine and mysterious phi (ϕ) or the golden ratio. A total of 140 teeth were included in the study. The crown-root ratio was manually calculated using vernier caliper and its approximation to golden ratio or the divine number phi (ϕ) was examined. The average root-crown ratio (R/C) for maxillary central incisor was 1.627 ± 0.04, and of its antagonist, mandibular central incisor was 1.628 ± 0.02. The tooth-root ratio (T/R) for the same was 1.609 ± 0.016 and 1.61 ± 0.008, respectively. Similar values were appreciated for lateral incisors where the R/C ratio in the maxillary and mandibular teeth was 1.632 ± 0.015 and 1.641 ± 0.012 and the T/R ratio was 1.606 ± 0.005 and 1.605 ± 0.005, respectively. On measuring the tooth length in linear fashion from the cusp tip to the root apex, we found that the tooth was divided into two parts at the cemento-enamel junction in the golden ratio. This information can be exploited in restorative and implant dentistry in future.

  18. Osseointegration of Implants Surface-Treated with Various Diameters of TiO2 Nano tubes in Rabbit

    International Nuclear Information System (INIS)

    Kang, Ch.G.; Park, Y.B.; Choi, H.; Lee, K.W.; Shim, J.S.; Oh, S.; Choi, S.H.

    2014-01-01

    The aim of this study was to evaluate the osseointegration of implants which were surface-treated with various diameters of TiO 2 nano tubes (30 nm, 70 nm, and 100 nm) in rabbit. Resorbable blast media (RBM) surfaced implants (Osstem, Busan, Korea) 3.5 mm in diameter and 8.5 mm in length were designated as the control group and the implants surface-treated with various diameters of nano tubes (30 nm, 70 nm, and 100 nm) with the same shapes were designated as the experimental groups. The implants were maintained unloaded for 4 and 12 weeks. After this period, the animals were sacrificed and micro-CT analysis, histomorphometric analysis (bone to implant contact (BIC), bone volume (BV)), and removal torque test were performed. Micro-CT analysis, histomorphometric analysis, and removal torque test results all showed the similar pattern, showing that 70 nm experimental group had the highest value at 4 weeks while 30 nm experimental group had the highest value at 12 weeks. Therefore, on the basis of the results above, it can be concluded that 30 nm and 70 nm TiO 2 nano tubes may have positive effects on osteogenesis and osseointegration depending on the healing time

  19. Electronic transport behavior of diameter-graded Ag nanowires

    International Nuclear Information System (INIS)

    Wang Xuewei; Yuan Zhihao

    2010-01-01

    Ag nanowires with a graded diameter in anodic aluminum oxide (AAO) membranes were fabricated by the direct-current electrodeposition. The Ag nanowires have a graded-change in diameter from 8 to 32 nm, which is matched with the graded-change of the AAO pore diameter. Electronic transport measurements show that there is a transport behavior similar to that of a metal-semiconductor junction along the axial direction in the diameter-graded Ag nanowires. Such a novel homogeneous nanojunction will be of great fundamental and practical significance.

  20. Electronic transport behavior of diameter-graded Ag nanowires

    Science.gov (United States)

    Wang, Xue Wei; Yuan, Zhi Hao

    2010-05-01

    Ag nanowires with a graded diameter in anodic aluminum oxide (AAO) membranes were fabricated by the direct-current electrodeposition. The Ag nanowires have a graded-change in diameter from 8 to 32 nm, which is matched with the graded-change of the AAO pore diameter. Electronic transport measurements show that there is a transport behavior similar to that of a metal-semiconductor junction along the axial direction in the diameter-graded Ag nanowires. Such a novel homogeneous nanojunction will be of great fundamental and practical significance.

  1. Joint variable frame rate and length analysis for speech recognition under adverse conditions

    DEFF Research Database (Denmark)

    Tan, Zheng-Hua; Kraljevski, Ivan

    2014-01-01

    This paper presents a method that combines variable frame length and rate analysis for speech recognition in noisy environments, together with an investigation of the effect of different frame lengths on speech recognition performance. The method adopts frame selection using an a posteriori signal......-to-noise (SNR) ratio weighted energy distance and increases the length of the selected frames, according to the number of non-selected preceding frames. It assigns a higher frame rate and a normal frame length to a rapidly changing and high SNR region of a speech signal, and a lower frame rate and an increased...... frame length to a steady or low SNR region. The speech recognition results show that the proposed variable frame rate and length method outperforms fixed frame rate and length analysis, as well as standalone variable frame rate analysis in terms of noise-robustness....

  2. Optimization of laser-induced breakdown spectroscopy for coal powder analysis with different particle flow diameters

    Energy Technology Data Exchange (ETDEWEB)

    Yao, Shunchun, E-mail: epscyao@scut.edu.cn [School of Electric Power, South China University of Technology, Guangzhou, Guangdong 510640 (China); State Key Laboratory of Pulsed Power Laser Technology, Electronic Engineering Institute, Hefei 230037 (China); Xu, Jialong; Dong, Xuan; Zhang, Bo; Zheng, Jianping [School of Electric Power, South China University of Technology, Guangzhou, Guangdong 510640 (China); Lu, Jidong, E-mail: jdlu@scut.edu.cn [School of Electric Power, South China University of Technology, Guangzhou, Guangdong 510640 (China)

    2015-08-01

    The on-line measurement of coal is extremely useful for emission control and combustion process optimization in coal-fired plant. Laser-induced breakdown spectroscopy was employed to directly analyze coal particle flow. A set of tapered tubes were proposed for beam-focusing the coal particle flow to different diameters. For optimizing the measurement of coal particle flow, the characteristics of laser-induced plasma, including optical breakdown, the relative standard deviation of repeated measurement, partial breakdown spectra ratio and line intensity, were carefully analyzed. The comparison of the plasma characteristics among coal particle flow with different diameters showed that air breakdown and the random change in plasma position relative to the collection optics could significantly influence on the line intensity and the reproducibility of measurement. It is demonstrated that the tapered tube with a diameter of 5.5 mm was particularly useful to enrich the coal particles in laser focus spot as well as to reduce the influence of air breakdown and random changes of plasma in the experiment. - Highlights: • Tapered tube was designed for beam-focusing the coal particle flow as well as enriching the particles in laser focus spot. • The characteristics of laser-induced plasma of coal particle flow were investigated carefully. • An appropriate diameter of coal particle flow was proven to benefit for improving the performance of LIBS measurement.

  3. Arecibo Radar Observation of Near-Earth Asteroids: Expanded Sample Size, Determination of Radar Albedos, and Measurements of Polarization Ratios

    Science.gov (United States)

    Lejoly, Cassandra; Howell, Ellen S.; Taylor, Patrick A.; Springmann, Alessondra; Virkki, Anne; Nolan, Michael C.; Rivera-Valentin, Edgard G.; Benner, Lance A. M.; Brozovic, Marina; Giorgini, Jon D.

    2017-10-01

    The Near-Earth Asteroid (NEA) population ranges in size from a few meters to more than 10 kilometers. NEAs have a wide variety of taxonomic classes, surface features, and shapes, including spheroids, binary objects, contact binaries, elongated, as well as irregular bodies. Using the Arecibo Observatory planetary radar system, we have measured apparent rotation rate, radar reflectivity, apparent diameter, and radar albedos for over 350 NEAs. The radar albedo is defined as the radar cross-section divided by the geometric cross-section. If a shape model is available, the actual cross-section is known at the time of the observation. Otherwise we derive a geometric cross-section from a measured diameter. When radar imaging is available, the diameter was measured from the apparent range depth. However, when radar imaging was not available, we used the continuous wave (CW) bandwidth radar measurements in conjunction with the period of the object. The CW bandwidth provides apparent rotation rate, which, given an independent rotation measurement, such as from lightcurves, constrains the size of the object. We assumed an equatorial view unless we knew the pole orientation, which gives a lower limit on the diameter. The CW also provides the polarization ratio, which is the ratio of the SC and OC cross-sections.We confirm the trend found by Benner et al. (2008) that taxonomic types E and V have very high polarization ratios. We have obtained a larger sample and can analyze additional trends with spin, size, rotation rate, taxonomic class, polarization ratio, and radar albedo to interpret the origin of the NEAs and their dynamical processes. The distribution of radar albedo and polarization ratio at the smallest diameters (≤50 m) differs from the distribution of larger objects (>50 m), although the sample size is limited. Additionally, we find more moderate radar albedos for the smallest NEAs when compared to those with diameters 50-150 m. We will present additional trends we

  4. Infant pupil diameter changes in response to others' positive and negative emotions.

    Directory of Open Access Journals (Sweden)

    Elena Geangu

    Full Text Available It has been suggested that infants resonate emotionally to others' positive and negative affect displays, and that these responses become stronger towards emotions with negative valence around the age of 12-months. In this study we measured 6- and 12-month-old infants' changes in pupil diameter when presented with the image and sound of peers experiencing happiness, distress and an emotionally neutral state. For all participants the perception of another's distress triggered larger pupil diameters. Perceiving other's happiness also induced larger pupil diameters but for shorter time intervals. Importantly, we also found evidence for an asymmetry in autonomous arousal towards positive versus negative emotional displays. Larger pupil sizes for another's distress compared to another's happiness were recorded shortly after stimulus onset for the older infants, and in a later time window for the 6-month-olds. These findings suggest that arousal responses for negative as well as for positive emotions are present in the second half of the first postnatal year. Importantly, an asymmetry with stronger responses for negative emotions seems to be already present at this age.

  5. Estimation of airway smooth muscle stiffness changes due to length oscillation using artificial neural network.

    Science.gov (United States)

    Al-Jumaily, Ahmed; Chen, Leizhi

    2012-10-07

    This paper presents a novel approach to estimate stiffness changes in airway smooth muscles due to external oscillation. Artificial neural networks are used to model the stiffness changes due to cyclic stretches of the smooth muscles. The nonlinear relationship between stiffness ratios and oscillation frequencies is modeled by a feed-forward neural network (FNN) model. The structure of the FNN is selected through the training and validation using literature data from 11 experiments with different muscle lengths, muscle masses, oscillation frequencies and amplitudes. Data pre-processing methods are used to improve the robustness of the neural network model to match the non-linearity. The validation results show that the FNN model can predict the stiffness ratio changes with a mean square error of 0.0042. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Evaporation induced diameter control in fiber crystal growth by micro-pulling-down technique: Bi{sub 4}Ge{sub 3}O{sub 12}

    Energy Technology Data Exchange (ETDEWEB)

    Chani, V.; Lebbou, K.; Hautefeuille, B.; Tillement, O. [Physical Chemistry of Luminescent Materials, Claude Bernard Lyon1 University, CNRS UMR 5620, Bat. A. Kastler, 10 rue Ampere, 69622 Villeurbanne Cedex (France); Fourmigue, J.M. [FiberCryst, 23 rue Royale, F-69001 Lyon (France)

    2006-10-15

    Diameter self-control was established in Bi{sub 4}Ge{sub 3}O{sub 12} fiber crystal growth by micro-pulling-down technique. In accordance with Bi{sub 2}O{sub 3}-GeO{sub 2} phase diagram, the diameter was controlled due to compensation of solidification with evaporation of volatile Bi{sub 2}O{sub 3} self-flux charged into the crucible with excess. The crucibles had capillary channels of 310 or 650 {mu}m in outer diameter. The crystals up to 400 mm long and 50-300 {mu}m in diameter were grown at pulling-down rates of 0.04-1.00 mm/min. The melt composition and the pulling rate were generally only two parameters determining solidification rate. As a result, crystals with uniform ({+-} 10%) diameter and aspect ratio up to 10{sup 4} were produced without automation of the process. (copyright 2006 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  7. Does Physical Fitness Buffer the Relationship between Psychosocial Stress, Retinal Vessel Diameters, and Blood Pressure among Primary Schoolchildren?

    Science.gov (United States)

    Endes, Katharina; Herrmann, Christian; Colledge, Flora; Brand, Serge; Donath, Lars; Faude, Oliver; Pühse, Uwe; Hanssen, Henner; Zahner, Lukas

    2016-01-01

    Background. Strong evidence exists showing that psychosocial stress plays an important part in the development of cardiovascular diseases. Because physical inactivity is associated with less favourable retinal vessel diameter and blood pressure profiles, this study explores whether physical fitness is able to buffer the negative effects of psychosocial stress on retinal vessel diameters and blood pressure in young children. Methods. 325 primary schoolchildren (51% girls, Mage = 7.28 years) took part in this cross-sectional research project. Retinal arteriolar diameters, retinal venular diameters, arteriolar to venular ratio, and systolic and diastolic blood pressure were assessed in all children. Interactions terms between physical fitness (performance in the 20 m shuttle run test) and four indicators of psychosocial stress (parental reports of critical life events, family, peer and school stress) were tested in a series of hierarchical regression analyses. Results. Critical life events and family, peer, and school-related stress were only weakly associated with retinal vessel diameters and blood pressure. No support was found for a stress-buffering effect of physical fitness. Conclusion. More research is needed with different age groups to find out if and from what age physical fitness can protect against arteriolar vessel narrowing and the occurrence of other cardiovascular disease risk factors. PMID:27795958

  8. Diameter 2 properties and convexity

    Czech Academy of Sciences Publication Activity Database

    Abrahamsen, T. A.; Hájek, Petr Pavel; Nygaard, O.; Talponen, J.; Troyanski, S.

    2016-01-01

    Roč. 232, č. 3 (2016), s. 227-242 ISSN 0039-3223 R&D Projects: GA ČR GA16-07378S Institutional support: RVO:67985840 Keywords : diameter 2 property * midpoint locally uniformly rotund * Daugavet property Subject RIV: BA - General Mathematics Impact factor: 0.535, year: 2016 https://www.impan.pl/pl/wydawnictwa/czasopisma-i-serie-wydawnicze/studia- mathematica /all/232/3/91534/diameter-2-properties-and-convexity

  9. PEGylation on mixed monolayer gold nanoparticles: Effect of grafting density, chain length, and surface curvature.

    Science.gov (United States)

    Lin, Jiaqi; Zhang, Heng; Morovati, Vahid; Dargazany, Roozbeh

    2017-10-15

    PEGylation on nanoparticles (NPs) is widely used to prevent aggregation and to mask NPs from the fast clearance system in the body. Understanding the molecular details of the PEG layer could facilitate rational design of PEGylated NPs that maximize their solubility and stealth ability without significantly compromising the targeting efficiency and cellular uptake. Here, we use molecular dynamics (MD) simulation to understand the structural and dynamic the PEG coating of mixed monolayer gold NPs. Specifically, we modeled gold NPs with PEG grafting densities ranging from 0-2.76chain/nm 2 , chain length with 0-10 PEG monomers, NP core diameter from 5nm to 500nm. It is found that the area accessed by individual PEG chains gradually transits from a "mushroom" to a "brush" conformation as NP surface curvature become flatter, whereas such a transition is not evident on small NPs when grafting density increases. It is shown that moderate grafting density (∼1.0chain/nm 2 ) and short chain length are sufficient enough to prevent NPs from aggregating in an aqueous medium. The effect of grafting density on solubility is also validated by dynamic light scattering measurements of PEGylated 5nm gold NPs. With respect to the shielding ability, simulations predict that increase either grafting density, chain length, or NP diameter will reduce the accessibility of the protected content to a certain size molecule. Interestingly, reducing NP surface curvature is estimated to be most effective in promoting shielding ability. For shielding against small molecules, increasing PEG grafting density is more effective than increasing chain length. A simple model that includes these three investigated parameters is developed based on the simulations to roughly estimate the shielding ability of the PEG layer with respect to molecules of different sizes. The findings can help expand our current understanding of the PEG layer and guide rational design of PEGylated gold NPs for a particular

  10. Effect of Aspect Ratio, Channel Orientation, Rib Pitch-to-Height Ratio, and Number of Ribbed Walls on Pressure Drop Characteristics in a Rotating Channel with Detached Ribs

    Directory of Open Access Journals (Sweden)

    K. Arun

    2007-01-01

    Full Text Available The present work involves experimental investigation of the effects of aspect ratio, channel orientation angle, rib pitch-to-height ratio (P/e, and number of ribbed walls on friction factor in orthogonally rotating channel with detached ribs. The ribs are separated from the base wall to provide a small region of flow between the base wall and the ribs. Experiments have been conducted at Reynolds number ranging from 10000–17000 with rotation numbers varying from 0–0.38. Pitch-to-rib height ratios (P/e of 5 and 10 at constant rib height-to-hydraulic diameter ratio (e/D of 0.1 and a clearance ratio (C/e of 0.38 are considered. The rib angle of attack with respect to mainstream flow is 90∘. The channel orientation at which the ribbed wall becomes trailing surface (pressure side on which the Coriolis force acts is considered as the 0∘ orientation angle. For one-wall ribbed case, channel is oriented from 0∘ to 180∘ about its axis in steps of 30∘ to change the orientation angle. For two-wall ribbed case, the orientation angle is changed from 0∘ to 90∘ in steps of 30∘. Friction factors for the detached ribbed channels are compared with the corresponding attached ribbed channel. It is found that in one-wall detached ribbed channel, increase in the friction factor ratio with the orientation angle is lower for rectangular channel compared to that of square channel for both the pitch-to-rib height ratios of 5 and 10 at a given Reynolds number and rotation number. Friction factor ratios of two-wall detached ribbed rectangular channel are comparable with corresponding two-wall detached ribbed square channel both under stationary and rotating conditions.

  11. Smaller Anterior Cruciate Ligament Diameter Is a Predictor of Subjects Prone to Ligament Injuries: An Ultrasound Study

    Directory of Open Access Journals (Sweden)

    Parag Suresh Mahajan

    2015-01-01

    Full Text Available Purpose. To test if diameter of normal anterior cruciate ligament (ACL can be measured by ultrasound (US, to see if there is a relationship between smaller ACL diameter and ACL injury, and to assess agreement between radiologists in measuring ACL diameter in cases and matched controls. Materials and Methods. In this ethics committee-approved study, maximum diameter of ACL near tibial insertion site was measured by static and dynamic US study in 25 normal contralateral knees of subjects who suffered noncontact ACL injury and in 25 matched control subjects. Results. ACL was visualized as a thick linear hypoechoic band inserted approximately 11 mm caudal to the tibial plateau and the intercondylar eminence. Maximum diameter of contralateral ACL near tibial insertion site among injured subjects was significantly smaller than in noninjured subjects (0.62 ± 0.07 cm versus 0.81 ± 0.06 cm; P<0.0001. In the regression analysis, the diameter of ACL near tibial insertion site was found significantly proportional to body weight and not significantly associated to height, gender, and age. Conclusion. Diameter of normal ACL near tibial insertion site can be measured by US and the maximum diameter is significantly smaller among subjects with noncontact ACL injury. US is a promising modality that can be used as an excellent screening test to detect subjects especially aspiring athletes prone to ACL injury. Very strong agreement was observed between radiologists in measuring ACL diameter.

  12. Shape-optimization of round-to-slot holes for improving film cooling effectiveness on a flat surface

    Science.gov (United States)

    Huang, Ying; Zhang, Jing-zhou; Wang, Chun-hua

    2018-06-01

    Single-objective optimization for improving adiabatic film cooling effectiveness is performed for single row of round-to-slot film cooling holes on a flat surface by using CFD analysis and surrogate approximation methods. Among the main geometric parameters, dimensionless hole-to-hole pitch ( P/ d) and slot length-to-diameter ( l/ d) are fixed as 2.4 and 2 respectively, and the other parameters (hole height-to-diameter ratio, slot width-to-diameter and inclination angle) are chosen as the design variables. Given a wide range of possible geometric variables, the geometric optimization of round-to-slot holes is carried out under two typical blowing ratios of M = 0.5 and M = 1.5 by selecting a spatially-averaged adiabatic film cooling effectiveness between x/ d = 2 and x/ d = 12 as the objective function to be maximized. Radial basis function neural network is applied for constructing the surrogate model and then the optimal design point is searched by a genetic algorithm. It is revealed that the optimal round-to-slot hole is of converging feature under a low blowing ratio but of diffusing feature under a high blowing ratio. Further, the influence principle of optimal round-to-slot geometry on film cooling performance is illustrated according to the detailed flow and thermal behaviors.

  13. Influence of the embedded structure on the EFP formation of compact terminal sensitive projectile

    Directory of Open Access Journals (Sweden)

    Bo-yang Xing

    2017-08-01

    Full Text Available To improve the damage efficiency of compact terminal sensitive projectile with EFP warhead, it is vital to understand how the embedded structure (ES affects the EFP forming performance. In this paper, the corresponding numerical investigation is focused on, in which the fluid-structure interaction (FSI method and the experimental verification are used. Based on the obtained quantitative relations between the forming performance and α (the ratio of height to maximum radius of ES, an optimal design is further provided. The results indicate that: when the embedded structural length and width range 0.1–0.3D and 0.1–0.2D (D: diameter of EFP warhead at a fixed volume, respectively, EFP forming velocity nearly keeps as a constant, 1760 m/s; the height of ES has a dramatical effect on the propagating range of detonation wave, resulting in significant influence on the aerodynamic shape and length-to-diameter ratio of EFP; under the given constraints, the EFP length-diameter ratio can reach the optimal value 2.76, when the height of ES is 0.22D.

  14. Improving CT detection sensitivity for nodal metastases in oesophageal cancer with combination of smaller size and lymph node axial ratio

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jianfang [Chinese Academy of Medical Sciences and Peking Union Medical College, National Cancer Center/Cancer Hospital, Beijing (China); Capital Medical University Electric Power Teaching Hospital, Beijing (China); Wang, Zhu; Qu, Dong; Yao, Libo [Chinese Academy of Medical Sciences and Peking Union Medical College, National Cancer Center/Cancer Hospital, Beijing (China); Shao, Huafei [Affiliated Yantai Yuhuangding Hospital of Qingdao University Medical College, Yantai (China); Liu, Jian [Meitan General Hospital, Beijing (China)

    2018-01-15

    To investigate the value of CT with inclusion of smaller lymph node (LN) sizes and axial ratio to improve the sensitivity in diagnosis of regional lymph node metastases in oesophageal squamous cell carcinoma (OSCC). The contrast-enhanced multidetector row spiral CT (MDCT) multiplanar reconstruction images of 204 patients with OSCC were retrospectively analysed. The long-axis and short-axis diameters of the regional LNs were measured and axial ratios were calculated (short-axis/long-axis diameters). Nodes were considered round if the axial ratio exceeded the optimal LN axial ratio, which was determined by receiver operating characteristic analysis. A positive predictive value (PPV) exceeding 50% is needed. This was achieved only with LNs larger than 9 mm in short-axis diameter, but nodes of this size were rare (sensitivity 37.3%, specificity 96.4%, accuracy 85.8%). If those round nodes (axial ratio exceeding 0.66) between 7 mm and 9 mm in size were considered metastases as well, it might improve the sensitivity to 67.2% with a PPV of 63.9% (specificity 91.6%, accuracy 87.2%). Combination of a smaller size and axial ratio for LNs in MDCT as criteria improves the detection sensitivity for LN metastases in OSCC. (orig.)

  15. Skin Blood Perfusion and Cellular Response to Insertion of Insulin Pen Needles With Different Diameters

    DEFF Research Database (Denmark)

    Præstmark, Kezia Ann; Stallknecht, Bente Merete; Bo Jensen, Casper

    2014-01-01

    skin blood perfusion response around needle insertion sites. Three common sized pen needles of 28G, 30G, and 32G as well as hooked 32G needles, were inserted into the neck skin of pigs and then removed. Laser Speckle Contrast Analysis was used to measure skin blood perfusion for 20 minutes after...... blood perfusion recording and grouped according to needle type, skin blood perfusion response relates to needle diameter. The response was significantly higher after insertions with 28G and hooked 32G needles than with 30G (P ..., but there was a trend of an increased response with increasing needle diameter. Skin blood perfusion response to pen needle insertions rank according to needle diameter, and the tissue response caused by hooked 32G needles corresponds to that of 28G needles. The relation between needle diameter and trauma when...

  16. Influence of platform diameter in the reliability and failure mode of extra-short dental implants.

    Science.gov (United States)

    Bordin, Dimorvan; Bergamo, Edmara T P; Bonfante, Estevam A; Fardin, Vinicius P; Coelho, Paulo G

    2018-01-01

    To evaluate the influence of implant diameter in the reliability and failure mode of extra-short dental implants. Sixty-three extra-short implants (5mm-length) were allocated into three groups according to platform diameter: Ø4.0-mm, Ø5.0-mm, and Ø6.0-mm (21 per group). Identical abutments were torqued to the implants and standardized crowns cemented. Three samples of each group were subjected to single-load to failure (SLF) to allow the design of the step-stress profiles, and the remaining 18 were subjected to step-stress accelerated life-testing (SSALT) in water. The use level probability Weibull curves, and the reliability (probability of survival) for a mission of 100,000 cycles at 100MPa, 200MPa, and 300MPa were calculated. Failed samples were characterized in scanning electron microscopy for fractographic inspection. No significant difference was observed for reliability regarding implant diameter for all loading missions. At 100MPa load, all groups showed reliability higher than 99%. A significant decreased reliability was observed for all groups when 200 and 300MPa missions were simulated, regardless of implant diameter. At 300MPa load, the reliability was 0%, 0%, and 5.24%, for Ø4.0mm, Ø5.0mm, and Ø6.0mm, respectively. The mean beta (β) values were lower than 0.55 indicating that failures were most likely influenced by materials strength, rather than damage accumulation. The Ø6.0mm implant showed significantly higher characteristic stress (η = 1,100.91MPa) than Ø4.0mm (1,030.25MPa) and Ø5.0mm implant (η = 1,012.97MPa). Weibull modulus for Ø6.0-mm implant was m = 7.41, m = 14.65 for Ø4.0mm, and m = 11.64 for Ø5.0mm. The chief failure mode was abutment fracture in all groups. The implant diameter did not influence the reliability and failure mode of 5mm extra-short implants. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. A small diameter, flexible, all attitude, self-contained germanium spectrometer. Operator's manual

    International Nuclear Information System (INIS)

    Bordzindki, R.L.; Lepel, E.A.; Reeves, J.H.; Kohli, R.

    1997-05-01

    The end of the Cold War has brought about tremendous changes in the nuclear complex of the Department of Energy. One of the many changes has been the shutdown or decommissioning of many facilities that performed nuclear work. One of the steps in the process of decommissioning a facility involves the decontamination or removal of drain lines or pipes that may have carried radioactive materials at one time. The removal of all these pipes and drain lines to a nuclear disposal facility could be quite costly. It was suggested by Pacific Northwest National Laboratory (PNNL) that a germanium spectrometer could be built that could fit through straight pipes with a diameter as small as 5.08 cm (2 inches) and pass through curved pipes with a diameter as small as 7.6 cm (3 inches) such as that of a 3-inch p-trap in a drain line. The germanium spectrometer could then be used to simultaneously determine all gamma-ray emitting radionuclides in or surrounding the pipe. By showing the absence of any gamma-ray emitting radionuclides, the pipes could then be reused in place or disposed of as non-radioactive material, thus saving significantly in disposal costs. A germanium spectrometer system has been designed by PNNL and fabricated by Princeton Gamma Tech (PGT) that consists of three segments, each 4.84 cm in diameter and about 10 cm in length. Flexible stainless steel bellows were used to connect the segments. Segment 1 is a small liquid nitrogen reservoir. The reservoir is filled with a sponge-like material which enables the detector to be used in any orientation. A Stirling cycle refrigerator is under development which can replace the liquid nitrogen reservoir to provide continuous cooling and operation

  18. Ultrasonographic criteria for fine needle aspiration of nonpalpable thyroid nodules 1–2 cm in diameter

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Yang, E-mail: j0kim040@louisville.edu [Department of Radiology, University of Louisville, 530 South Jackson Street, Louisville, KY 40242 (United States); Department of Healthcare System Gangnam Center, Department of Radiology, Seoul National University Hospital, 737 Star tower, 40 floor, Yeoksam-dong, Gangnam-gu, Seoul 135-080 (Korea, Republic of); Kim, Soo Young; Yang, Ki Ra [Department of Healthcare System Gangnam Center, Department of Radiology, Seoul National University Hospital, 737 Star tower, 40 floor, Yeoksam-dong, Gangnam-gu, Seoul 135-080 (Korea, Republic of)

    2013-02-15

    Purpose: To investigate the ultrasonographic (US) characteristics for nonpalpable thyroid nodules 1–2 cm in diameter and to evaluate the guideline for fine needle aspiration (FNA) in terms of US findings. Materials and methods: Between June 2005 and November 2006, FNA was performed in 919 thyroid nodules by radiologists. Of these nodules, 51 malignant nodules and 72 benign nodules were finally included. All 123 nodules were analyzed by 3 radiologists if there were the following US characteristics: marked hypoechogenecity, hypoechogenecity, isoechogenecity, hyperechogenecity, microcalcification, coarse calcification, rim calcification, spiculated margin, taller-than-wide shape, irregular shape, hypoechoic rim and honeycomb appearance. The maximum diameters of nodules and thickness of hypoechoic rim were measured. US characteristics relevant as predictors were identified using a Chi-square or Fisher's exact test and odds ratio. We compared the diagnostic efficacy of 3 US criteria for FNA indication. Results: Microcalcification, taller-than-wide shape, marked hypoechogenecity, hypoechogenecity, coarse calcification, irregular shape and spiculated margin were significant characteristics of malignant nodules. Isoechogenecity, hypoechoic rim and honeycomb appearance was significant characteristics of benign nodules. Rim or arc calcification, hyperechogenecity and thickness of hypoechoic rim were insignificant. Among 3 US criteria for FNA indication, NFI showed the highest diagnostic efficacy, 98.0% in sensitivity, 75.0% in specificity and 150.0 in odds ratio. Conclusion: As for nonpalpable thyroid nodules 1–2 cm in diameter, US characteristics are useful for differentiating between malignant and benign nodules. Malignant US characteristics and honeycombing appearance have significant value in selecting nodules for biopsy and reducing the frequency of the FNA procedure.

  19. How to optimize therapeutic ratio in brachytherapy of head and neck squamous cell carcinoma?

    International Nuclear Information System (INIS)

    Mazeron, J.J.; Simon, J.M.; Hardiman, C.; Gerbaulet, A.

    1998-01-01

    Considerable experience has been accumulated with low dose rate (LDR) brachytherapy in the treatment of squamous cell carcinoma of the oral cavity and oropharynx, 4 cm or less in diameter. Recent analysis of large clinical series provided data indicating that modalities of LDR brachytherapy should be optimized in treating these tumours for increasing therapeutic ratio. LDR brachytherapy is now challenged by high dose rate (HDR) brachytherapy and pulsed dose rate (PDR) brachytherapy. Preliminary results obtained with the last two modalities are discussed in comparison with those achieved with LDR brachytherapy. (orig.)

  20. Comparison of Mesa and Device Diameter Variation in Double Wafer-Fused Multi Quantum-Well, Long-Wavelength, Vertical Cavity Surface Emitting Lasers

    International Nuclear Information System (INIS)

    Menon, P.S.; Kandiah, K.; Burhanuddin Yeop Majlis; Shaari, S.

    2011-01-01

    Long-wavelength vertical-cavity surface-emitting lasers (LW-VCSELs) have profound advantages compared to traditional edge-emitting lasers offering improved properties with respect to mode selectivity, fibre coupling, threshold currents and integration into 2D arrays or with other electronic devices. Its commercialization is gaining momentum as the local and access network in optical communication system expand. Numerical modeling of LW-VCSEL utilizing wafer-fused InP-based multi-quantum wells (MQW) and GaAs-based distributed Bragg reflectors (DBRs) is presented in this paper. Emphasis is on the device and mesa/pillar diameter design parameter comparison and its effect on the device characteristics. (author)