WorldWideScience

Sample records for length pennation angle

  1. Architectural adaptations of muscle to training and injury: a narrative review outlining the contributions by fascicle length, pennation angle and muscle thickness.

    Science.gov (United States)

    Timmins, Ryan G; Shield, Anthony J; Williams, Morgan D; Lorenzen, Christian; Opar, David A

    2016-01-27

    The architectural characteristics of muscle (fascicle length, pennation angle muscle thickness) respond to varying forms of stimuli (eg, training, immobilisation and injury). Architectural changes following injury are thought to occur in response to the restricted range of motion experienced during rehabilitation and the associated neuromuscular inhibition. However, it is unknown if these differences exist prior to injury, and had a role in injury occuring (prospectively), or if they occur in response to the incident itself (retrospectively). Considering that the structure of a muscle will influence how it functions, it is of interest to understand how these architectural variations may alter how a muscle acts with reference to the force-length and force-velocity relationships. Our narrative review provides an overview of muscle architectural adaptations to training and injury. Specifically, we (1) describe the methods used to measure muscle architecture; (2) detail the impact that architectural alterations following training interventions, immobilisation and injury have on force production and (3) present a hypothesis on how neuromuscular inhibition could cause maladaptations to muscle architecture following injury. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  2. A computational approach to calculate personalized pennation angle based on MRI: effect on motion analysis.

    Science.gov (United States)

    Chincisan, Andra; Tecante, Karelia; Becker, Matthias; Magnenat-Thalmann, Nadia; Hurschler, Christof; Choi, Hon Fai

    2016-05-01

    Muscles are the primary component responsible for the locomotion and change of posture of the human body. The physiologic basis of muscle force production and movement is determined by the muscle architecture (maximum muscle force, [Formula: see text], optimal muscle fiber length, [Formula: see text], tendon slack length, [Formula: see text], and pennation angle at optimal muscle fiber length, [Formula: see text]). The pennation angle is related to the maximum force production and to the range of motion. The aim of this study was to investigate a computational approach to calculate subject-specific pennation angle from magnetic resonance images (MRI)-based 3D anatomical model and to determine the impact of this approach on the motion analysis with personalized musculoskeletal models. A 3D method that calculates the pennation angle using MRI was developed. The fiber orientations were automatically computed, while the muscle line of action was determined using approaches based on anatomical landmarks and on centroids of image segmentation. Three healthy male volunteers were recruited for MRI scanning and motion capture acquisition. This work evaluates the effect of subject-specific pennation angle as musculoskeletal parameter in the lower limb, focusing on the quadriceps group. A comparison was made for assessing the contribution of personalized models on motion analysis. Gait and deep squat were analyzed using neuromuscular simulations (OpenSim). The results showed variation of the pennation angle between the generic and subject-specific models, demonstrating important interindividual differences, especially for the vastus intermedius and vastus medialis muscles. The pennation angle variation between personalized and generic musculoskeletal models generated significant variation in muscle moments and forces during dynamic motion analysis. A MRI-based approach to define subject-specific pennation angle was proposed and evaluated in motion analysis models. The

  3. A computational model to investigate the effect of pennation angle on surface electromyogram of Tibialis Anterior.

    Directory of Open Access Journals (Sweden)

    Diptasree Maitra Ghosh

    Full Text Available This study has described and experimentally validated the differential electrodes surface electromyography (sEMG model for tibialis anterior muscles during isometric contraction. This model has investigated the effect of pennation angle on the simulated sEMG signal. The results show that there is no significant effect of pennation angle in the range 0° to 20° to the single fibre action potential shape recorded on the skin surface. However, the changes with respect to pennation angle are observed in sEMG amplitude, frequency and fractal dimension. It is also observed that at different levels of muscle contractions there is similarity in the relationships with Root Mean Square, Median Frequency, and Fractal Dimension of the recorded and simulated sEMG signals.

  4. Dynamic measurement of pennation angle of gastrocnemius muscles during contractions based on ultrasound imaging

    Directory of Open Access Journals (Sweden)

    Zhou Yongjin

    2012-09-01

    Full Text Available Abstract Background Muscle fascicle pennation angle (PA is an important parameter related to musculoskeletal functions, and ultrasound imaging has been widely used for measuring PA, but manually and frame by frame in most cases. We have earlier reported an automatic method to estimate aponeurosis orientation based on Gabor transform and Revoting Hough Transform (RVHT. Methods In this paper, we proposed a method to estimate the overall orientation of muscle fascicles in a region of interest, in order to complete computing the orientation of the other side of the pennation angle, but the side found by RVHT. The measurements for orientations of both fascicles and aponeurosis were conducted in each frame of ultrasound images, and then the dynamic change of pennation angle during muscle contraction was obtained automatically. The method for fascicle orientation estimation was evaluated using synthetic images with different noise levels and later on 500 ultrasound images of human gastrocnemius muscles during isometric plantarflexion. Results The muscle fascicle orientations were also estimated manually by two operators. From the results it’s found that the proposed automatic method demonstrated a comparable performance to the manual method. Conclusions With the proposed methods, ultrasound measurement for muscle pennation angles can be more widely used for functional assessment of muscles.

  5. Reliability and validity of a dual-probe personal computer-based muscle viewer for measuring the pennation angle of the medial gastrocnemius muscle in patients who have had a stroke.

    Science.gov (United States)

    Cho, Ji-Eun; Cho, Ki Hun; Yoo, Jun Sang; Lee, Su Jin; Lee, Wan-Hee

    2018-01-01

    Background A dual-probe personal computer-based muscle viewer (DPC-BMW) is advantageous in that it is relatively lightweight and easy to apply. Objective To investigate the reliability and validity of the DPC-BMW in comparison with those of a portable ultrasonography (P-US) device for measuring the pennation angle of the medial gastrocnemius (MG) muscle at rest and during contraction. Methods Twenty-four patients who had a stroke (18 men and 6 women) participated in this study. Using the DPC-BMW and P-US device, the pennation angle of the MG muscle on the affected side was randomly measured. Two examiners randomly obtained the images of all the participants in two separate test sessions, 7 days apart. Intraclass correlation coefficient (ICC), confidence interval, standard error of measurement, Bland-Altman plot, and Pearson correlation coefficient were used to estimate their reliability and validity. Results The ICC for the intrarater reliability of the MG muscle pennation angle measured using the DPC-BMW was > 0.916, indicating excellent reliability, and that for the interrater reliability ranged from 0.964 to 0.994. The P-US device also exhibited good reliability. A high correlation was found between the measurements of MG muscle pennation angle obtained using the DPC-BMW and that obtained using the P-US device (p < 0.01). Conclusion The DPC-BMW can provide clear images for accurate measurements, including measurements using dual probes. It has the advantage of rehabilitative US imaging for individuals who have had a stroke. More research studies are needed to evaluate the usefulness of the DPC-BMW in rehabilitation.

  6. Intra- and inter-rater reliabilities of measurement of ultrasound imaging for muscle thickness and pennation angle of tibialis anterior muscle in stroke patients.

    Science.gov (United States)

    Cho, Ki Hun; Lee, Hwang Jae; Lee, Wan Hee

    2017-07-01

    Dysfunction of skeletal muscle has been commonly reported in stroke patients. The purpose of this study was to investigate the intra- and inter-rater reliabilities of measurement of ultrasound imaging (USI) for pennation angle (PA) and muscle thickness (MT) of tibialis anterior muscle in stroke patients. Thirty-four stroke patients (19 men) participated in this study. USI was used for measurement of PA and MT of the tibialis anterior muscles at rest and during maximum voluntary contraction (MVC). Two examiners acquired images from all participants during two separate testing sessions, seven days apart. Intra-class correlation coefficients (ICCs), confidence interval (CI), standard error of measurement, minimal detectable change, and Bland-Altman plots were used for estimation of reliability. In the intra-rater reliability between measures, for all variables (PA and MT of the paretic and non-paretic sides of tibialis anterior muscles at rest and during MVC), the ICCs ranged between 0.639 and 0.998 and the CI was within an acceptable range of 0.388-0.999. In inter-rater reliability between examiners for the two tests, for all variables, the ICCs ranged between 0.690 and 0.995 and the CI was within an acceptable range of 0.463-0.997. In addition, significant difference was observed between the paretic and non-paretic sides of the tibialis anterior muscle architecture (p stroke patients. In addition, objective and quantitative measurements of tibialis anterior muscle using USI may provide appropriate management for the walking recovery of stroke patients.

  7. Kernel density estimation applied to bond length, bond angle, and torsion angle distributions.

    Science.gov (United States)

    McCabe, Patrick; Korb, Oliver; Cole, Jason

    2014-05-27

    We describe the method of kernel density estimation (KDE) and apply it to molecular structure data. KDE is a quite general nonparametric statistical method suitable even for multimodal data. The method generates smooth probability density function (PDF) representations and finds application in diverse fields such as signal processing and econometrics. KDE appears to have been under-utilized as a method in molecular geometry analysis, chemo-informatics, and molecular structure optimization. The resulting probability densities have advantages over histograms and, importantly, are also suitable for gradient-based optimization. To illustrate KDE, we describe its application to chemical bond length, bond valence angle, and torsion angle distributions and show the ability of the method to model arbitrary torsion angle distributions.

  8. Multistability inspired by the oblique, pennate architectures of skeletal muscle

    Science.gov (United States)

    Kidambi, Narayanan; Harne, Ryan L.; Wang, K. W.

    2017-04-01

    Skeletal muscle mechanics exhibit a range of noteworthy characteristics, providing great inspiration for the development of advanced structural and material systems. These characteristics arise from the synergies demonstrated between muscle's constituents across the various length scales. From the macroscale oblique orientation of muscle fibers to the microscale lattice spacing of sarcomeres, muscle takes advantage of geometries and multidimensionality for force generation or length change along a desired axis. Inspired by these behaviors, this research investigates how the incorporation of multidimensionality afforded by oblique, pennate architectures can uncover novel mechanics in structures exhibiting multistability. Experimental investigation of these mechanics is undertaken using specimens of molded silicone rubber with patterned voids, and results reveal tailorable mono-, bi-, and multi-stability under axial displacements by modulation of transverse confinement. If the specimen is considered as an architected material, these results show its ability to generate intriguing, non-monotonic shear stresses. The outcomes would foster the development of novel, advanced mechanical metamaterials that exploit pennation and multidimensionality.

  9. Ergonomics study on the handle length and lift angle for the culinary spatula.

    Science.gov (United States)

    Wu, Swei-Pi; Hsieh, Chang-Sheng

    2002-09-01

    The culinary spatula (turning shovel) is one of the most common cooking tools used in the kitchen in Asia. However, the culinary spatula has seldom been ergonomically investigated. When a person uses a spatula to cook food, the operations involve repetitive bent-wrist motions, such as dorsiflexion, palmary flexion, and radial and ulnar deviations. These movements may cause cumulative trauma disorders in the upper extremities, and in particular carpal tunnel syndrome. A poorly designed culinary spatula will be ergonomically inefficient and cause injury to the hand and wrist. The purpose of this study was to investigate the effects of spatula handle length and lift angle on food-frying, food-turning, and food-shoveling performance. Eight female subjects were tested using 16 different culinary spatulas, with four different handle lengths (20, 25, 30 and 35 cm) and four different lift angles (15 degrees, 25 degrees, 35 degrees and 45 ). The criterion measures included cooking performance, and rating of perceived exertion. The subjects ranked their preference after all of the tasks in the tests were completed. The results showed that: (1) The handle length had a significant influence on the cooking performance, and rating of perceived exertion. The optimal handle lengths for frying food, turning food, and shoveling food were 20, 25 and 25 cm, respectively. (2) The lift angle significantly affected the cooking performance, and rating of perceived exertion. The optimal lift angles for frying food, turning food, and shoveling food were 15 degrees, 15 degrees and 25 degrees, respectively. (3) Both the handle length and lift angle had significant effects on subjective preference. For the handle length, the 20 cm length was the best. For the lift angle, the 25 angle was the best. (4) In general, a spatula with a 20 cm handle length and 25 degrees lift angle was the best. A spatula with a 25 cm handle length and 15 lift angle was the second most preferred. (5) However, to

  10. Contact Angle Measurement of Small Capillary Length Liquid in Super-repelled State.

    Science.gov (United States)

    Liu, Tingyi Leo; Kim, Chang-Jin Cj

    2017-04-07

    The difficulty of measuring very large contact angles (>150 degrees) has become more relevant with the increased popularity of super-repellent surfaces. Measurement is more difficult for dynamic contact angles, for which theoretical profiles do not fit well, and small capillary length liquids, whose sessile droplets sag by gravity. Here, we expand the issue to the limit by investigating dynamic contact angles of liquids with an extremely small capillary length (contact angles can be measured with a consistent accuracy despite their vastly different capillary lengths if one keeps the lens magnification inversely proportional to the capillary length. Verifying the droplet equator height is a key parameter, we propose a new Bond number defined by the equator height and optical resolution to represent the measurement accuracy of large contact angles. Despite negligible improvement for most liquids today, the proposed approach teaches how to measure very large contact angles with consistent accuracy when any of the liquids in consideration has a capillary length below 1.0 mm.

  11. Effects of setting angle and chord length on performance of four blades bionic wind turbine

    Science.gov (United States)

    Yang, Z. X.; Li, G. S.; Song, L.; Bai, Y. F.

    2017-11-01

    With the energy crisis and the increasing environmental pollution, more and more efforts have been made about wind power development. In this paper, a four blades bionic wind turbine was proposed, and the outline of wind turbine was constructed by the fitted curve. This paper attempted to research the effects of setting angle and chord length on performance of four blades bionic wind turbine by computational fluid dynamics (CFD) simulation. The results showed that the setting angle and chord length of the bionic wind turbine has some significant effects on the efficiency of the wind turbine, and within the range of wind speed from 7 m/s to 15 m/s, the wind turbine achieved maximum efficiency when the setting angle is 31 degree and the chord length is 125 mm. The conclusion will work as a guideline for the improvement of wind turbine design

  12. Effects of Blade Discharge Angle, Blade Number and Splitter Blade Length on Deep Well Pump Performance

    OpenAIRE

    E. Korkmaz; M. Gölcü; C. Kurbanoğlu

    2017-01-01

    Impellers with splitter blades are used for pumps and compressors in the design of turbomachines. Design parameters such as the number of blades, blade discharge angle and impeller discharge diameter impact affect pump performance and energy consumption. In this study, the effect of the number of blades (z=5, 6, and 7), blade discharge angles (β2b=25, and β2b=35) and splitter blade lengths (40, 55, 70, and 85% of the main blade length) on Deep Well Pump (DWP) performance has been studied ex...

  13. Studying fractal geometry on submicron length scales by small-angle scattering

    International Nuclear Information System (INIS)

    Wong, P.; Lin, J.

    1988-01-01

    Recent studies have shown that internal surfaces of porous geological materials, such as rocks and lignite coals, can be described by fractals down to atomic length scales. In this paper, the basic properties of self-similar and self-affine fractals are reviewed and how fractal dimensions can be measured by small-angle scattering experiments are discussed

  14. Measurement of contact angles of microscopic droplets by focal length method.

    Science.gov (United States)

    Geiger, Daniel; Geiger, Kirsten; Neckernuss, Tobias; Marti, Othmar; Amirkhani, Masoud

    2017-08-01

    We present a method to measure contact angles of microscopic droplets with a conventional microscope that possesses a precision focus adjustment stage. The droplets are modeled as spherical caps that act as lenses. Their focal length is determined by measuring the distance from the substrate surface to the level where a sharp image of the aperture stop is observed. The lens diameter is found by edge detection of a microscope image of the microdroplets. The spherical cap model relates the focal length and diameter of such lenses to the contact angle of the used liquid with known refractive index. The measurement procedure was applied to condensed water droplets on a silicon substrate covered by its native oxide layer. The results are found to be in good agreement with conventional, goniometric sessile drop measurements of the advancing contact angle.

  15. Moment arms and lengths of human upper limb muscles as functions of joint angles.

    Science.gov (United States)

    Pigeon, P; Yahia, L; Feldman, A G

    1996-10-01

    Modeling of musculoskeletal structures requires accurate data on anatomical parameters such as muscle lengths (MLs), moment arms (MAs) and those describing the upper limb position. Using a geometrical model of planar arm movements with three degrees of freedom, we present, in an analytical form, the available information on the relationship between MAs and MLs and joint angles for thirteen human upper limb muscles. The degrees of freedom included are shoulder flexion/extension, elbow flexion/extension, and either wrist flexion/extension (the forearm in supination) or radial/ulnar deviation (the forearm in mid-pronation). Previously published MA/angle curves were approximated by polynomials. ML/angle curves were obtained by combining the constant values of MLs (defined by the distance between the origin and insertion points for a specific upper limb position) with a variable part obtained by multiplying the MA (joint radius) and the joint angle. The MAs of the prime wrist movers in radial/ulnar deviation were linear functions of the joint angle (R2 > or = 0.9954), while quadratic polynomials accurately described their MAs during wrist flexion/extensions. The relationship between MAs and the elbow angle was described by 2nd, 3rd or 5th-order polynomials (R2 > or = 0.9904), with a lesser quality of fit for the anconeus (R2 = 0.9349). In the full range of angular displacements, the length of wrist, elbow and shoulder muscles can change by 8.5, 55 and 200%, respectively.

  16. In vivo moment arm lengths for hip extensor muscles at different angles of hip flexion.

    Science.gov (United States)

    Németh, G; Ohlsén, H

    1985-01-01

    Moment arm lengths of three hip extensor muscles, the gluteus maximus, the hamstrings and the adductor magnus, were determined at hip flexion angles from 0 degrees to 90 degrees by combining data from ten autopsy specimens and from twenty patients, the latter examined by computed tomography. A straight-line muscle model for muscle force was used for the hamstrings and adductor magnus, and for the gluteus maximus a two-segment straight-line muscle force model was used. With the joint in its anatomical position the moment arm of the gluteus maximus to the bilateral motion axis averaged 79 mm, for the hamstrings 61 mm and for the adductor magnus 15 mm. The moment arm of gluteus maximus decreased with increasing hip flexion angle. The hamstrings showed an increase in moment arm length up to an average of 35 degrees hip flexion and then a decrease with increasing hip flexion angle. The corresponding figures for the adductor magnus moment arm showed an increase up to 75 degrees and then a decrease. Statistical analysis revealed significant differences in moment arm length between men and women.

  17. Magnetic alloy nanowire arrays with different lengths: Insights into the crossover angle of magnetization reversal process

    Energy Technology Data Exchange (ETDEWEB)

    Samanifar, S.; Alikhani, M. [Department of Physics, University of Kashan, Kashan 87317-51167 (Iran, Islamic Republic of); Almasi Kashi, M., E-mail: almac@kashanu.ac.ir [Department of Physics, University of Kashan, Kashan 87317-51167 (Iran, Islamic Republic of); Institute of Nanoscience and Nanotechnology, University of Kashan, Kashan 87317-51167 (Iran, Islamic Republic of); Ramazani, A. [Department of Physics, University of Kashan, Kashan 87317-51167 (Iran, Islamic Republic of); Institute of Nanoscience and Nanotechnology, University of Kashan, Kashan 87317-51167 (Iran, Islamic Republic of); Montazer, A.H. [Institute of Nanoscience and Nanotechnology, University of Kashan, Kashan 87317-51167 (Iran, Islamic Republic of)

    2017-05-15

    Nanoscale magnetic alloy wires are being actively investigated, providing fundamental insights into tuning properties in magnetic data storage and processing technologies. However, previous studies give trivial information about the crossover angle of magnetization reversal process in alloy nanowires (NWs). Here, magnetic alloy NW arrays with different compositions, composed of Fe, Co and Ni have been electrochemically deposited into hard-anodic aluminum oxide templates with a pore diameter of approximately 150 nm. Under optimized conditions of alumina barrier layer and deposition bath concentrations, the resulting alloy NWs with aspect ratio and saturation magnetization (M{sub s}) up to 550 and 1900 emu cm{sup −3}, respectively, are systematically investigated in terms of composition, crystalline structure and magnetic properties. Using angular dependence of coercivity extracted from hysteresis loops, the reversal processes are evaluated, indicating non-monotonic behavior. The crossover angle (θ{sub c}) is found to depend on NW length and M{sub s}. At a constant M{sub s}, increasing NW length decreases θ{sub c}, thereby decreasing the involvement of vortex mode during the magnetization reversal process. On the other hand, decreasing M{sub s} decreases θ{sub c} in large aspect ratio (>300) alloy NWs. Phenomenologically, it is newly found that increasing Ni content in the composition decreases θ{sub c}. The angular first-order reversal curve (AFORC) measurements including the irreversibility of magnetization are also investigated to gain a more detailed insight into θ{sub c}. - Highlights: • Magnetic alloy NWs with aspect ratios up to 550 were fabricated into hard-AAO templates. • Morphology, composition, crystal structure and magnetic properties were investigated. • Angular dependence of coercivity was used to describe the magnetization reversal process. • The crossover angle of magnetization reversal was found to depend on NW length and M{sub s}.

  18. MRI Evaluation of Spinal Length and Vertebral Body Angle During Loading with a Spinal Compression Harness

    Science.gov (United States)

    Campbell, James A.; Hargens, Alan R.; Murthy, G.; Ballard, R. E.; Watenpaugh, D. E.; Hargens, Alan, R.; Sanchez, E.; Yang, C.; Mitsui, I.; Schwandt, D.; hide

    1998-01-01

    Weight bearing by the spinal column during upright posture often plays a role in the common problem of low back pain. Therefore, we developed a non-ferromagnetic spinal compression harness to enable MRI investigations of the spinal column during axial loading. Human subjects were fitted with a Nest and a footplate which were connected by adjustable straps to an analog load cell. MRI scans of human subjects (5 males and 1 female with age range of 27-53 yrs) during loaded and unloaded conditions were accomplished with a 1.5 Tesla GE Signa scanner. Studies of two subjects undergoing sequentially increasing spinal loads revealed significant decreases (r(sup 2) = 0.852) in spinal length between T4 and L5 culminating in a 1.5 to 2% length decrease during loading with 75% body weight. Sagittal vertebral body angles of four subjects placed under a constant 50% body weight load for one hour demonstrated increased lordotic and kyphotic curvatures. In the lumbar spine, the L2 vertebral body experienced the greatest angular change (-3 deg. to -5 deg.) in most subjects while in the thoracic spine, T4 angles increased from the unloaded state by +2 deg. to +9 deg. Overall, our studies demonstrate: 1) a progressive, although surprisingly small, decrease in spinal length with increasing load and 2) relatively large changes in spinal column angulation with 50% body weight.

  19. Phene synergism between root hair length and basal root growth angle for phosphorus acquisition.

    Science.gov (United States)

    Miguel, Magalhaes Amade; Postma, Johannes Auke; Lynch, Jonathan Paul

    2015-04-01

    Shallow basal root growth angle (BRGA) increases phosphorus acquisition efficiency by enhancing topsoil foraging because in most soils, phosphorus is concentrated in the topsoil. Root hair length and density (RHL/D) increase phosphorus acquisition by expanding the soil volume subject to phosphorus depletion through diffusion. We hypothesized that shallow BRGA and large RHL/D are synergetic for phosphorus acquisition, meaning that their combined effect is greater than the sum of their individual effects. To evaluate this hypothesis, phosphorus acquisition in the field in Mozambique was compared among recombinant inbred lines of common bean (Phaseolus vulgaris) having four distinct root phenotypes: long root hairs and shallow basal roots, long root hairs and deep basal roots, short root hairs and shallow basal roots, and short root hairs and deep basal roots. The results revealed substantial synergism between BRGA and RHL/D. Compared with short-haired, deep-rooted phenotypes, long root hairs increased shoot biomass under phosphorus stress by 89%, while shallow roots increased shoot biomass by 58%. Genotypes with both long root hairs and shallow roots had 298% greater biomass accumulation than short-haired, deep-rooted phenotypes. Therefore, the utility of shallow basal roots and long root hairs for phosphorus acquisition in combination is twice as large as their additive effects. We conclude that the anatomical phene of long, dense root hairs and the architectural phene of shallower basal root growth are synergetic for phosphorus acquisition. Phene synergism may be common in plant biology and can have substantial importance for plant fitness, as shown here. © 2015 American Society of Plant Biologists. All Rights Reserved.

  20. Increased hallux angle in children and its association with insufficient length of footwear: A community based cross-sectional study

    Directory of Open Access Journals (Sweden)

    Kundi Michael

    2009-12-01

    Full Text Available Abstract Background Wearing shoes of insufficient length during childhood has often been cited as leading to deformities of the foot, particularly to the development of hallux valgus disorders. Until now, these assumptions have not been confirmed through scientific research. This study aims to investigate whether this association can be statistically proven, and if children who wear shoes of insufficient length actually do have a higher risk of a more pronounced lateral deviation of the hallux. Methods 858 pre-school children were included in the study. The study sample was stratified by sex, urban/rural areas and Austrian province. The hallux angle and the length of the feet were recorded. The inside length of the children's footwear (indoor shoes worn in pre-school and outdoor shoes were assessed. Personal data and different anthropometric measurements were taken. The risk of hallux valgus deviation was statistically tested by a stepwise logistic regression analysis and the relative risk (odds ratio for a hallux angle ≥ 4 degrees was calculated. Results Exact examinations of the hallux angle could be conducted on a total of 1,579 individual feet. Only 23.9% out of 1,579 feet presented a straight position of the great toe. The others were characterized by lateral deviations (valgus position at different degrees, equalling 10 degrees or greater in 14.2% of the children's feet. 88.8% of 808 children examined wore indoor footwear that was of insufficient length, and 69.4% of 812 children wore outdoor shoes that were too short. A significant relationship was observed between the lengthwise fit of the shoes and the hallux angle: the shorter the shoe, the higher the value of the hallux angle. The relative risk (odds ratio of a lateral hallux deviation of ≥ 4 degrees in children wearing shoes of insufficient length was significantly increased. Conclusions There is a significant relationship between the hallux angle in children and footwear that is

  1. Increased hallux angle in children and its association with insufficient length of footwear: A community based cross-sectional study

    Science.gov (United States)

    2009-01-01

    Background Wearing shoes of insufficient length during childhood has often been cited as leading to deformities of the foot, particularly to the development of hallux valgus disorders. Until now, these assumptions have not been confirmed through scientific research. This study aims to investigate whether this association can be statistically proven, and if children who wear shoes of insufficient length actually do have a higher risk of a more pronounced lateral deviation of the hallux. Methods 858 pre-school children were included in the study. The study sample was stratified by sex, urban/rural areas and Austrian province. The hallux angle and the length of the feet were recorded. The inside length of the children's footwear (indoor shoes worn in pre-school and outdoor shoes) were assessed. Personal data and different anthropometric measurements were taken. The risk of hallux valgus deviation was statistically tested by a stepwise logistic regression analysis and the relative risk (odds ratio) for a hallux angle ≥ 4 degrees was calculated. Results Exact examinations of the hallux angle could be conducted on a total of 1,579 individual feet. Only 23.9% out of 1,579 feet presented a straight position of the great toe. The others were characterized by lateral deviations (valgus position) at different degrees, equalling 10 degrees or greater in 14.2% of the children's feet. 88.8% of 808 children examined wore indoor footwear that was of insufficient length, and 69.4% of 812 children wore outdoor shoes that were too short. A significant relationship was observed between the lengthwise fit of the shoes and the hallux angle: the shorter the shoe, the higher the value of the hallux angle. The relative risk (odds ratio) of a lateral hallux deviation of ≥ 4 degrees in children wearing shoes of insufficient length was significantly increased. Conclusions There is a significant relationship between the hallux angle in children and footwear that is too short in length. The

  2. Improvement in muscle strength with low-load isotonic training depends on fascicle length but not joint angle.

    Science.gov (United States)

    Tanaka, Hiroki; Ikezoe, Tome; Nakamura, Masatoshi; Yanase, Ko; Fujita, Kosuke; Motomura, Yoshiki; Kusano, Ken; Araki, Kojiro; Umehara, Jun; Saeki, Junya; Morishita, Katsuyuki; Ichihashi, Noriaki

    2018-01-01

    In this study we investigate whether low-load isotonic training will elicit greater improvement in muscle strength at the same fascicle length, rather than at the same joint angle. Sixteen healthy men (24.1 ± 2.5 years of age) were randomly divided into intervention and control groups. Pre- and posttraining maximum isometric and isokinetic strengths and fascicle lengths of the medial gastrocnemius muscle were measured. Isotonic resistance training at 15 ° to 30 ° ankle plantarflexion at low intensity was conducted for 4 weeks. The maximum isometric and isokinetic strength of the intervention group increased significantly only at 15 ° dorsiflexion and 8 ° to 12 ° dorsiflexion. Fascicle length during maximum voluntary contraction at 15 ° dorsiflexion to 0 ° was similar to fascicle length under training conditions. It is possible that the improvement in muscle strength with low-load training depends on fascicle length rather than joint angle. Muscle Nerve 57: 83-89, 2018. © 2017 Wiley Periodicals, Inc.

  3. Validation of hamstrings musculoskeletal modeling by calculating peak hamstrings length at different hip angles

    NARCIS (Netherlands)

    van der Krogt, M.M.; Doorenbosch, C.A.M.; Harlaar, J.

    2008-01-01

    Accurate estimates of hamstrings lengths are useful, for example, to facilitate planning for surgical lengthening of the hamstrings in patients with cerebral palsy. In this study, three models used to estimate hamstrings length (M1: Delp, M2: Klein Horsman, M3: Hawkins and Hull) were evaluated. This

  4. Determination of bulk diffusion lengths for angle-lapped semiconductor material via the scanning electron microscope: A theoretical analysis

    Science.gov (United States)

    Vonroos, O.

    1978-01-01

    A standard procedure for the determination of the minority carrier diffusion length by means of a scanning electron microscope (SEM) consists in scanning across an angle-lapped surface of a P-N junction and measuring the resultant short circuit current I sub sc as a function of beam position. A detailed analysis of the I sub sc originating from this configuration is presented. It is found that, for a point source excitation, the I sub sc depends very simply on x, the variable distance between the surface and the junction edge. The expression for the I sub sc of a planar junction device is well known. If d, the constant distance between the plane of the surface of the semiconductor and the junction edge in the expression for the I of a planar junction is merely replaced by x, the variable distance of the corresponding angle-lapped junction, an expression results which is correct to within a small fraction of a percent as long as the angle between the surfaces, 2 theta sub 1, is smaller than 10 deg.

  5. Investigating the Effect of IMF Path Length on Pitch-angle Scattering of Strahl within 1 au

    Science.gov (United States)

    Graham, G. A.; Rae, I. J.; Owen, C. J.; Walsh, A. P.

    2018-03-01

    Strahl is the strongly field-aligned, beam-like population of electrons in the solar wind. Strahl width is observed to increase with distance from the Sun, and hence strahl electrons must be subject to in-transit scattering effects. Different energy relations have been both observed and modeled for both strahl width and the width increase with radial distance. Thus, there is much debate regarding what mechanism(s) scatter strahl. In this study, we use a novel method to investigate strahl evolution within 1 au by estimating the distance traveled by the strahl along the interplanetary magnetic field (IMF). We do this by implementing methods developed in previous studies, which make use of the onset of solar energetic particles at ∼1 au. Thus, we are able to obtain average strahl broadening in relation to electron energy and distance, while also taking into account the general effect of IMF topology and adiabatic focusing experienced by strahl. We find that average strahl width broadens with distance traveled along the IMF, which suggests that strahl width is related to the path length taken by the strahl from the Sun to 1 au. We also find that strahl pitch-angle width broadening per au along the IMF length increased with strahl energy, which suggests that the dominant strahl pitch-angle scattering mechanism likely has an inherent energy relation. Our pitch-angle broadening results provide a testable energy relation for the upcoming Parker Solar Probe and Solar Orbiter missions, which are both set to provide unprecedented new observations within 1 au.

  6. Estimation of axial curvature of anterior sclera: correlation between axial length and anterior scleral curvature as affected by angle kappa.

    Science.gov (United States)

    Lee, Sang-Mok; Choi, Hyuk Jin; Choi, Heejin; Kim, Mee Kum; Wee, Won Ryang

    2016-10-07

    BACKGROUND: Though the development and fitting of scleral contact lenses are expanding steadily, there is no simple method to provide scleral metrics for scleral contact lens fitting yet. The aim of this study was to establish formulae for estimation of the axial radius of curvature (ARC) of the anterior sclera using ocular biometric parameters that can be easily obtained with conventional devices. A semi-automated stitching method and a computational analysis tool for calculating ARC were developed by using the ImageJ and MATLAB software. The ARC of all the ocular surface points were analyzed from the composite horizontal cross-sectional images of the right eyes of 24 volunteers; these measurements were obtained using anterior segment optical coherence tomography for a previous study (AS-OCT; Visante). Ocular biometric parameters were obtained from the same volunteers with slit-scanning topography and partial coherence interferometry. Correlation analysis was performed between the ARC at 8 mm to the axis line (ARC[8]) and other ocular parameters (including age). With ARC obtained on several nasal and temporal points (7.0, 7.5, 8.0, 8.5, and 9.0 mm from the axis line), univariate and multivariate linear regression analyses were performed to develop a model for estimating ARC with the help of ocular biometric parameters. Axial length, spherical equivalent, and angle kappa showed correlations with temporal ARC[8] (tARC[8]; Pearson's r = 0.653, -0.579, and -0.341; P = 0.001, 0.015, and 0.015, respectively). White-to-white corneal diameter (WTW) and anterior chamber depth (ACD) showed correlation with nasal ARC[8] (nARC[8]; Pearson's r = -0.492 and -0.461; P = 0.015 and 0.023, respectively). The formulae for estimating scleral curvatures (tARC, nARC, and average ARC) were developed as a function of axial length, ACD, WTW, and distance from the axis line, with good determinant power (72 - 80 %; SPSS ver. 22.0). Angle kappa showed strong

  7. Sexual reproduction in plagiogrammacean diatoms: First insights into the early pennates.

    Directory of Open Access Journals (Sweden)

    Irena Kaczmarska

    Full Text Available The genera Plagiogramma and Dimeregramma are members of a small, but evolutionarily important group of diatoms, the "basal" araphids. They are sister to all other pennates, both araphid and raphid taxa. Thus, their phylogenetic position carries the potential for providing insights into the earliest pennates. We documented sexual reproduction, mating system and sex cell development in the first members of the "basal" araphid clade ever investigated. The mating system in all these species involved heterothally. It was, however, more complex in P. tsawwassen, where in addition to heterothallic clones, intraclonal and polysexual clones also exist. Auxospore development and wall structure was similar in all three species and demonstrated several characters also reported from "core" araphids. Of these, vigorous, pseudopodial motility of male secondary spermatocytes and gametes was most notable because it indicates that this character was likely present in the last common ancestor of all the pennates. Pseudopodial motility of the male sex cells might have afforded sufficient compensation and/or benefits to the emerging pennates for replacing flagellated sperm, present in centrics. The characters thus far uniquely present among our plagiogrammaceans but not reported from other pennates were: the "gametic" fusion between sex-compatible secondary spermatocytes, in some cases before completion of Meiosis II in males, transverse perizonial bands produced all together or in quick succession rather than being added to the auxospore apex one at a time, and expanding auxospores with 3-4 nuclei. An initial epivalve, similar in morphology to what in some diatoms had been interpreted as a "longitudinal" perizonium, may be more widespread among pennates than thus far appreciated. In addition, we discovered two species new to science (D. acutumontgo, P. tsawwassen, and refined delineation of P. staurophorum by including metric data from the original material.

  8. Sexual reproduction in plagiogrammacean diatoms: First insights into the early pennates.

    Science.gov (United States)

    Kaczmarska, Irena; Gray, Benjamin S; Ehrman, James M; Thaler, Mary

    2017-01-01

    The genera Plagiogramma and Dimeregramma are members of a small, but evolutionarily important group of diatoms, the "basal" araphids. They are sister to all other pennates, both araphid and raphid taxa. Thus, their phylogenetic position carries the potential for providing insights into the earliest pennates. We documented sexual reproduction, mating system and sex cell development in the first members of the "basal" araphid clade ever investigated. The mating system in all these species involved heterothally. It was, however, more complex in P. tsawwassen, where in addition to heterothallic clones, intraclonal and polysexual clones also exist. Auxospore development and wall structure was similar in all three species and demonstrated several characters also reported from "core" araphids. Of these, vigorous, pseudopodial motility of male secondary spermatocytes and gametes was most notable because it indicates that this character was likely present in the last common ancestor of all the pennates. Pseudopodial motility of the male sex cells might have afforded sufficient compensation and/or benefits to the emerging pennates for replacing flagellated sperm, present in centrics. The characters thus far uniquely present among our plagiogrammaceans but not reported from other pennates were: the "gametic" fusion between sex-compatible secondary spermatocytes, in some cases before completion of Meiosis II in males, transverse perizonial bands produced all together or in quick succession rather than being added to the auxospore apex one at a time, and expanding auxospores with 3-4 nuclei. An initial epivalve, similar in morphology to what in some diatoms had been interpreted as a "longitudinal" perizonium, may be more widespread among pennates than thus far appreciated. In addition, we discovered two species new to science (D. acutumontgo, P. tsawwassen), and refined delineation of P. staurophorum by including metric data from the original material.

  9. Lower-limb lengths and angles in children older than six years: Reliability and reference values by EOS®stereoradiography.

    Science.gov (United States)

    Rampal, V; Rohan, P-Y; Assi, A; Ghanem, I; Rosello, O; Simon, A-L; Gaumetou, E; Merzoug, V; Skalli, W; Wicart, P

    2017-11-07

    Lower-limb alignment in children is classically assessed clinically or based on conventional radiography, which is associated with projection bias. Low-dose biplanar radiography was described recently as an alternative to conventional imaging. The primary objective of this study was to assess the reliability of length and angle values inferred from 3D reconstructions in children seen in everyday practice. The secondary objective was to obtain reference values for goniometry parameters in children. 3D reconstructions can be used to assess the lower limbs in children. The paediatric reliability study was done in 18 volunteers who were divided into three groups based on whether they were typically developing (TD) children, had skeletal development abnormalities, or had cerebral palsy. The reference data were obtained in 129 TD children. Each study participant underwent biplanar radiography with 3D reconstruction performed by experts and radiology technicians. Goniometry parameters were computed automatically. Reproducibility was assessed based on the intra-class coefficient (ICC) and the ISO 5725 standard (standard deviation of reproducibility, SDR). For length parameters, the ICCs ranged from 0.94 to 1.00 and the SDR from 2.1 to 3.5mm. For angle parameters, the ICC and SDR ranges were 0.60-0.95 and 0.9°-4.6°, respectively. No significant differences were found across experts or radiology technicians. Age-specific reference data are reported. These findings confirm the reliability of low-dose biplanar radiography for assessing lower-limb parameters in children seen in clinical practice. In addition, the study provides reference data for commonly measured parameters. IV. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  10. Influence of Joint Angle on Residual Force Enhancement in Human Plantar Flexors

    Directory of Open Access Journals (Sweden)

    Atsuki Fukutani

    2017-04-01

    Full Text Available Compared to pure isometric contractions, isometric muscle force at a given length is larger when the eccentric contraction is conducted before the isometric contraction. This phenomenon is widely known as residual force enhancement, and has been confirmed consistently in isolated muscle experiments. The purpose of this study was to confirm whether residual force enhancement also occurs in human plantar flexors and to examine its joint angle dependence. Eleven men participated in this study. Isometric joint torque was measured in a Control trial (pure isometric contraction and Residual force enhancement (RFE trial (isometric contraction after eccentric contraction at plantar flexion 0° (Short condition and dorsiflexion 15° (Long condition. Fascicle length and pennation angle of the medial gastrocnemius were measured simultaneously to evaluate the influence of architectural parameters on isometric joint torque. Isometric joint torque observed in the Short condition was not significantly different between the Control and RFE trials (Control: 42.9 ± 8.0 Nm, RFE: 45.1 ± 8.4 Nm (p = 0.200. In contrast, significant differences in isometric joint torque were observed in the Long condition between Control and RFE trials (Control: 40.5 ± 9.3 Nm, RFE: 47.1 ± 10.5 Nm (p = 0.001. Fascicle length and pennation angle were not different between Control and RFE trials in the Short and Long conditions. Isometric joint torque was larger when eccentric contraction was conducted before isometric contraction while architectural differences were not observed, indicating that residual force enhancement occurs in human plantar flexors. However, the influence of residual force enhancement may be limited in dorsiflexed positions because the magnitude of residual force enhancement is considered to be prominent in the descending limb (long muscle length condition and small in the ascending limb (short muscle length condition where human plantar flexors operate in

  11. Monitoring rapid valve formation in the pennate diatom Navicula salinarum (Bacillariophyceae)

    NARCIS (Netherlands)

    Hazelaar, S; van der Strate, HJ; Gieskes, WWC; Vrieling, EG

    After each division of a diatom cell, a new siliceous hypovalve is formed inside the silica deposition vesicle (SDV). We present the sequence of this early formation of the new valve in the pennate marine diatom Navicula salinarum (Grunow) Hustedt, visualized by using the fluorescent probe

  12. Structural factors determining photophysical properties of directly linked zinc(II) porphyrin dimers: linking position, dihedral angle, and linkage length.

    Science.gov (United States)

    Cho, Sung; Yoon, Min-Chul; Lim, Jong Min; Kim, Pyosang; Aratani, Naoki; Nakamura, Yasuyuki; Ikeda, Toshiaki; Osuka, Atsuhiro; Kim, Dongho

    2009-08-06

    We have investigated the relationship between the photophysical properties and structures of a series of directly linked zinc(II) porphyrin dimers (mmZ2, mbZ2, and bbZ2) using time-resolved spectroscopic measurements and theoretical calculations. Their unique characters such as CT nature and torsional motion are caused by interporphyrin interactions and steric effects, respectively, which can be fully understood in terms of three structural factors: linking position, dihedral angle, and linkage length. The orthogonal geometry and heterolinking of mmZ2 and mbZ2 induce the localized MOs and electron unbalance in the constituent porphyrin units, respectively, and consequently lead to distinct CT characters in spite of their different origin. On the other hand, a small interporphyrin steric hindrance in bbZ2 makes a torsional motion possible around the direct beta-beta' linkage in the excited state, which is correlated with the solvent dependence of the fast S(1) fluorescence decay component. On the basis of this work, we can gain further insight into the effect of individual structural factors on the photophysical properties, which provides a firm basis for further understanding of the photophysical properties mainly determined by the structural factors in multiporphyrin systems.

  13. Selection of optimal expansion angle and length of an expandable implant in the osteoporotic mandible: a three-dimensional finite element analysis.

    Science.gov (United States)

    Xiao, Jian-Rui; Kong, Liang; Chen, Yu-Xuan; Han, Xiao-Xian; Li, Yong-Feng

    2013-01-01

    To identify from a biomechanical point of view the optimal parameters for an expandable implant in the osteoporotic mandible, a three-dimensional finite element model (FEM) of an expandable implant was created with variations in expansion angle and expansion length. FEMs of osteoporotic posterior mandibular segments with an expandable implant were created. An axial load of 100 N and a buccolingual load of 30 N were applied to the implant. The expansion angle ranged from 0 to 4 degrees, and the expansion length ratio ranged from 1/6 to 5/6. The maximum equivalent stress (max EQV stress) in jawbone and the implant-abutment complex and the maximum displacement in the implant-abutment complex were evaluated. With changes in the expansion angle and expansion length ratio, the max EQV stress in cortical and cancellous bone increased by 12.4% and 73.9%, respectively, under axial loading, respectively, and by 38.6% and 69.1%, respectively, under buccolingual loading. The max EQV stress in the implant-abutment complex increased by 65.3% and 160% under axial and buccolingual loading, respectively. Maximum displacement in the implant-abutment complex increased by 3.66% and 19.73% under axial and buccolingual loading, respectively. Expansion angles and the expansion length ratio favored stress distribution in jawbone under axial and buccolingual loads, respectively. An expansion angle between 1.5 and 2.5 degrees and an expansion length ratio between 2/6 and 3/6 provided optimal biomechanical properties for an expandable implant in the osteoporotic mandible.

  14. Changes in Intra-pelvic Obliquity Angle 0-2 Years After Total Hip Arthroplasty and Its Effects on Leg Length Discrepancy: A Retrospective Study

    Directory of Open Access Journals (Sweden)

    Yin Zhang

    2015-01-01

    Full Text Available Background: Total hip arthroplasty (THA is one of the most effective treatments for phase III and IV hip arthrosis. Lower limb length balancing is one of the determining factors of a successful surgery, particularly in patients with developmental dysplasia of the hip (DDH. The purpose of this study was to evaluate the postoperative change in intra-pelvic obliquity (intra-PO angle in the coronal plane and its effects on leg length discrepancy (LLD within 2 years. Methods: A total of 78 patients (70 females, 8 males were enrolled in this study. All patients were suffering from DDH with varying degrees of LLD. Pelvic plain radiographs were collected before and after the operation. The intra-PO angles were measured 0, 0.5, 1 and 2 years after THA. At the same time, postoperative LLD was measured with blocking test. Results: PO changed significantly in the first year after THA surgery (0 year vs. 0.5 year, P < 0.01; 0.5 year vs. 1 year, P < 0.01, and the changing value of intra-PO angle (ΔPO slowed down substantially during the first 2 years after THA (0.5 year vs. 0.5-1 year, P < 0.01; 0.5-1 year vs. 1-2 years, P < 0.01. With the change in intra-PO angle, LLD also got narrow within the 1st year (0 year vs. 0.5 year, P < 0.01; 0.5 year vs. 1 year, P < 0.01. Elderly patients had a smaller intra-PO angle reduction (Group A vs. Group B, P = 0.01; Group B vs. Group C, P < 0.01. Conclusions: Intra-PO angle and LLD gap narrowed with time after THA surgery. In particular, elderly patients had smaller change in intra-PO angle.

  15. Accessible length scale of the in-plane structure in polarized neutron off-specular and grazing-incidence small-angle scattering measurements

    Science.gov (United States)

    Maruyama, R.; Bigault, T.; Wildes, A. R.; Dewhurst, C. D.; Saerbeck, T.; Honecker, D.; Yamazaki, D.; Soyama, K.; Courtois, P.

    2017-06-01

    Polarized neutron off-specular and grazing-incidence small-angle scattering measurements are useful methods to investigate the in-plane structure and its correlation of layered systems. Although these measurements give information on complementary and overlapping length scale, the different characteristics between them need to be taken into account when performed. In this study, the difference in the accessible length scale of the in-plane structure, which is one of the most important characteristics, was discussed using an Fe/Si multilayer together with simulations based on the distorted wave Born approximation.

  16. The accuracy of three-dimensional fused deposition modeling (FDM) compared with three-dimensional CT-Scans on the measurement of the mandibular ramus vertical length, gonion-menton length, and gonial angle

    Science.gov (United States)

    Savitri, I. T.; Badri, C.; Sulistyani, L. D.

    2017-08-01

    Presurgical treatment planning plays an important role in the reconstruction and correction of defects in the craniomaxillofacial region. The advance of solid freeform fabrication techniques has significantly improved the process of preparing a biomodel using computer-aided design and data from medical imaging. Many factors are implicated in the accuracy of the 3D model. To determine the accuracy of three-dimensional fused deposition modeling (FDM) models compared with three-dimensional CT scans in the measurement of the mandibular ramus vertical length, gonion-menton length, and gonial angle. Eight 3D models were produced from the CT scan data (DICOM file) of eight patients at the Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, University of Indonesia, Cipto Mangunkusumo Hospital. Three measurements were done three times by two examiners. The measurements of the 3D CT scans were made using OsiriX software, while the measurements of the 3D models were made using a digital caliper and goniometry. The measurement results were then compared. There is no significant difference between the measurements of the mandibular ramus vertical length, gonion-menton length, and gonial angle using 3D CT scans and FDM 3D models. FDM 3D models are considered accurate and are acceptable for clinical applications in dental and craniomaxillofacial surgery.

  17. HAMSTRING ARCHITECTURAL AND FUNCTIONAL ADAPTATIONS FOLLOWING LONG VS. SHORT MUSCLE LENGTH ECCENTRIC TRAINING

    Directory of Open Access Journals (Sweden)

    Kenny Guex

    2016-08-01

    Full Text Available Most common preventive eccentric-based exercises, such as Nordic hamstring do not include any hip flexion. So, the elongation stress reached is lower than during the late swing phase of sprinting. The aim of this study was to assess the evolution of hamstring architectural (fascicle length and pennation angle and functional (concentric and eccentric optimum angles and concentric and eccentric peak torques parameters following a 3-week eccentric resistance program performed at long (LML versus short muscle length (SML. Both groups performed eight sessions of 3-5x8 slow maximal eccentric knee extensions on an isokinetic dynamometer: the SML group at 0° and the LML group at 80° of hip flexion. Architectural parameters were measured using ultrasound imaging and functional parameters using the isokinetic dynamometer. The fascicle length increased by 4.9% (p<0.01, medium effect size in the SML and by 9.3% (p<0.001, large effect size in the LML group. The pennation angle did not change (p=0.83 in the SML and tended to decrease by 0.7° (p=0.09, small effect size in the LML group. The concentric optimum angle tended to decrease by 8.8° (p=0.09, medium effect size in the SML and by 17.3° (p<0.01, large effect size in the LML group. The eccentric optimum angle did not change (p=0.19, small effect size in the SML and tended to decrease by 10.7° (p=0.06, medium effect size in the LML group. The concentric peak torque did not change in the SML (p=0.37 and the LML (p=0.23 groups, whereas eccentric peak torque increased by 12.9% (p<0.01, small effect size and 17.9% (p<0.001, small effect size in the SML and the LML group, respectively. No group-by-time interaction was found for any parameters. A correlation was found between the training-induced change in fascicle length and the change in concentric optimum angle (r=-0.57, p<0.01. These results suggest that performing eccentric exercises lead to several architectural and functional adaptations. However

  18. Light is a key factor in triggering sexual reproduction in the pennate diatom Haslea ostrearia.

    Science.gov (United States)

    Mouget, Jean-Luc; Gastineau, Romain; Davidovich, Olga; Gaudin, Pierre; Davidovich, Nickolai A

    2009-08-01

    Sexual reproduction is an obligatory phase in the life cycle of most diatoms, as cell size decreases with successive vegetative divisions and the maximal cell size is only restored by a specialized cell, the auxospore, which follows zygote formation as a result of sexual reproduction. While in pennate diatoms the induction of sexual reproduction depends primarily on cell-cell interactions, the importance of different external factors for the induction of sexual reproduction is less well known. Here, we investigated the effects of light on sexualization in the marine benthic pennate diatom Haslea ostrearia (Gaillon) R. Simonsen. Compatible clones were crossed and exposed to different combinations of light levels, qualities, and photoperiods. Light was found to be a key factor for sexualization, and to a certain extent, to control auxosporulation in H. ostrearia. The light conditions most favorable for sexual reproduction were low irradiances (<50 micromolphotons m(-2) s(-1)) and short photoperiods (6-10 h), conditions that prevail during winter, and to a lesser extent, the higher irradiances and longer photoperiods that correspond to the spring and fall, when blooms of this organism form in the natural environment. Auxospore formation was very rare in continuous light, and maximum in presence of red radiation, while it was never observed in darkness or in radiation other than red.

  19. Mechanism of male gamete motility in araphid pennate diatoms from the genus Tabularia (Bacillariophyta).

    Science.gov (United States)

    Davidovich, Nickolai A; Kaczmarska, Irena; Karpov, Sergey A; Davidovich, Olga I; MacGillivary, Michael L; Mather, Laura

    2012-05-01

    During sexual reproduction, araphid pennate diatoms of the genus Tabularia (Kützing) D. M. Williams and Round released male gametes directly into the medium, sometimes at a considerable distance from the female gametes. This raised the question of how male gametes, suspended in water, manage to reach female ones, given that no locomotive organelles have been described in gametes of pennate diatoms. Optical microscopic investigation revealed cytoplasmic projections produced by male gametes of Tabularia tabulata (C. A. Agardh) Snoeijs and T. fasciculata (C. A. Agardh) D. M. Williams and Round. Morphology and behavior of these projections is consistent with pseudopodia, however, which specific type of pseudopodia they may be, remains inconclusive. The growth and retraction of the pseudopodia coincided with gamete motility and so we postulate that it explains the otherwise apparent random movement of male gametes. Spinning, shuffling and chaotic patterns of motility were documented. In theory, gamete mobility increases the probability of gamete encounter thus enhancing the probability of syngamy. This is the first known case where cytoplasmic projections have been described in diatom gametes, and possibly in mature gametes in general. Copyright © 2011 Elsevier GmbH. All rights reserved.

  20. Molecular conformation of the full-length tumor suppressor NF2/Merlin--a small-angle neutron scattering study.

    Science.gov (United States)

    Ali Khajeh, Jahan; Ju, Jeong Ho; Atchiba, Moussoubaou; Allaire, Marc; Stanley, Christopher; Heller, William T; Callaway, David J E; Bu, Zimei

    2014-07-29

    The tumor suppressor protein Merlin inhibits cell proliferation upon establishing cell-cell contacts. Because Merlin has high level of sequence similarity to the Ezrin-Radixin-Moesin family of proteins, the structural model of Ezrin-Radixin-Moesin protein autoinhibition and cycling between closed/resting and open/active conformational states is often employed to explain Merlin function. However, recent biochemical studies suggest alternative molecular models of Merlin function. Here, we have determined the low-resolution molecular structure and binding activity of Merlin and a Merlin(S518D) mutant that mimics the inactivating phosphorylation at S518 using small-angle neutron scattering and binding experiments. Small-angle neutron scattering shows that, in solution, both Merlin and Merlin(S518D) adopt a closed conformation, but binding experiments indicate that a significant fraction of either Merlin or Merlin(S518D) is capable of binding to the target protein NHERF1. Upon binding to the phosphatidylinositol 4,5-bisphosphate lipid, the wild-type Merlin adopts a more open conformation than in solution, but Merlin(S518D) remains in a closed conformation. This study supports a rheostat model of Merlin in NHERF1 binding and contributes to resolving a controversy about the molecular conformation and binding activity of Merlin. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Development and reliability of the Achilles Tendon Length Measure and comparison with the Achilles Tendon Resting Angle on patients with an Achilles tendon rupture

    DEFF Research Database (Denmark)

    Hansen, Maria Swennergren; Barfod, Kristoffer Weisskirchner; Kristensen, Morten Tange

    2017-01-01

    BACKGROUND: There is a need for a valid, reliable, and easily applicable clinical measure of the length of the Achilles tendon (AT) after rupture. This study examines the reliability of a new ruler based measurement, the Achilles Tendon Length Measure (ATLM) in comparison with the goniometer......-based Achilles Tendon Resting Angle (ATRA). METHODS: Measurements were performed by two independent physiotherapists eight weeks after AT rupture on 28 patients treated non-operatively. RESULTS: The mean (SD) injured ATLM was 56.5 (2.3)cm, ICC2.1 0.91(CI [0.72-0.97]), SEM 0.7cm (SEM% 1.2), MDC 1.9cm (MDC% 3...

  2. Assessment of hamstring muscle length in school-aged children using the sit-and-reach test and the inclinometer measure of hip joint angle.

    Science.gov (United States)

    Cornbleet, S L; Woolsey, N B

    1996-08-01

    The sit-and-reach test (SRT) is commonly used to assess flexibility of the spine and length of the hamstring muscles. The purposes of this study were (1) to describe hamstring muscle length as reflected by use of the SRT and the hip joint angle (HJA) in children, (2) to examine the correlation between SRT and HJA measurements, and (3) to examine gender differences for both measures. The participants were 410 school-aged children (211 girls, 199 boys). Each child performed the SRT. In the final position, the SRT score was obtained and the HJA was measured using an inclinometer placed over the sacrum. A mean SRT value of 24 cm and a mean HJA value of 81 degrees were obtained for all subjects. There was a strong correlation between the SRT and HJA measurements (r = .76). There was a difference between boys and girls for both measures. The results suggest differences in expectations for hamstring muscle length in boys and girls. Although scores for the SRT and HJA were correlated, we prefer to assess hamstring muscle length using HJA scores because these scores are not influenced by anthropometric factors or spinal mobility. The results of this study suggest that HJA measurements guide treatment more effectively than do SRT measurements.

  3. A rapidly deposited pennate diatom ooze in Upper Miocene-Lower Pliocene sediment beneath the North Pacific polar front

    Science.gov (United States)

    Dickens, G.R.; Barron, J.A.

    1997-01-01

    Rapidly deposited Thalassionema-Thalassiothrix pennate diatom oozes previously have been described in Upper Miocene-Lower Pliocene sediment beneath the frontal boundary of the eastern equatorial Pacific. Here we document a new occurrence of Thalassionema-Thalassiothrix ooze in Upper Miocene Lower Pliocene sediment beneath the frontal boundary of the subarctic North Pacific. The ooze is a 6 m interval of siliceous sediment at Ocean Drilling Program (ODP) sites 885/886 that was rapidly deposited between approximately 5.0 and 5.9 Ma. Bulk sediment in this interval may contain greater than 85% pennate diatom tests. There are also abundant laminae and pockets that are composed entirely of Thalassionema and Thalassiothrix diatoms. The presence of a rapidly deposited ooze dominated by pennate diatoms indicates unusual past conditions in the overlying surface waters. Time coincident deposition of such oozes at two distinct frontal boundary locations of the Pacific suggests that the unusual surface water conditions were causally linked to large-scale oceanographic change. This same oceanographic change most likely involved (1) addition of nutrients to the ocean, or (2) redistribution of nutrients within the ocean. The occurrence and origin of pennate diatom oozes may be a key component to an integrative understanding of late Neogene paleoceanography and biogeochemical cycling.

  4. Adhesive modular proteins occur in the extracellular mucilage of the motile, pennate diatom Phaeodactylum tricornutum.

    Science.gov (United States)

    Dugdale, Tony M; Willis, Anusuya; Wetherbee, Richard

    2006-04-15

    This Letter reports on adhesive modular proteins recorded by atomic force microscopy on live cells from the extracellular mucilage secreted from, and deposited around, the motile form of the pennate diatom Phaeodactylum tricornutum. This is the first report of modular proteins and their supramolecular assemblies, called adhesive nanofibers (ANFs), to be found on diatoms that use adhesives not only for substratum adhesion, but as a conduit for cell motility. The permanent adhesive pads secreted by Toxarium undulatum, a sessile centric diatom, were previously shown to possess ANFs with a modular protein backbone. Our results reported here suggest that modular proteins may be an important component of diatom adhesives in general, and that diatoms utilize the tensile strength, toughness, and flexibility of ANFs for multiple functions. Significantly, the genome of P. tricornutum has recently been sequenced; this will allow directed searches of the genome to be made for genes with modular protein homologs, and subsequent detailed studies of their molecular structure and function.

  5. Validity of hamstring muscle length assessment during the sit-and-reach test using an inclinometer to measure hip joint angle.

    Science.gov (United States)

    Youdas, James W; Krause, David A; Hollman, John H

    2008-01-01

    The aim of this study was twofold: (i) to describe the criterion-related validity of the sit-and-reach test (SRT) using a hand-held inclinometer when assessing hamstring muscle length (HML) when HML is recorded in degrees of hip joint angle (HJA); and (ii) to describe the effect of gender and age on HML in healthy adults during the performance of a SRT. We examined 212 healthy subjects (106 men and 106 women) whose ages ranged from 20 to 79 years. The Pearson-product moment correlation coefficient (r) described the relationship between HJA at the end-point of the SRT and the criterion, supine passive straight-leg raise (PSLR). We conducted a 6 x 2 analysis of variance, where age was stratified on 6 levels of 10-year increments (20-29, 30-39, 40-49, 50-59, 60-69, and 70-79 years of age) and gender was stratified on 2 levels (men and women). There was a statistically significant correlation (r = 0.59, P sitting position on a hard surface. Clinicians should recognize there are differences in HML between men and women, and that men and women between 20 to 49 years of age have more HML than their counterparts between ages 60 to 79 years.

  6. [Cutaneous electro-gastroenterography for evaluation of changes in the gastrointestinal tract in consequence of various angles of inclination and length of head-down tilt].

    Science.gov (United States)

    Afonin, B V; Sedova, E A; Goncharova, N P; Valuev, V A

    2006-01-01

    Experimental results were compared with data of cutaneous electro-gastroenterography and USI of the gastrointestinal tract in human subjects at different tilt angles and after different periods of tilting. It was shown that increased GIT electrical activity in tilted subjects before meal is representative of increasing intracavetary contents of the stomach and small intestine. More intensive electrical activity results from elevation of the GIT tone and peristalsis. Extension of tilt duration raises GIT tone and peristalsis and, consequently, stimulates the GIT electrical activity. Further increase of the tilt angle suppresses evacuation and, therefore, the electrical activity Analysis of the results allows conclusion that increased parameters of the total energy of GIT electrical potentials are reflective of elevated tone of GIT walls, whereas elongation of the potential peaks envelope implies activation of peristalsis.

  7. Phase Behavior of Blends of Linear and Branched Polyethylenes on Micron-Length Scales via Ultra-Small-Angle Neutron Scattering (USANS)

    International Nuclear Information System (INIS)

    Agamalian, M.M.; Alamo, R.G.; Londono, J.D.; Mandelkern, L.; Wignall, G.D.

    1999-01-01

    SANS experiments on blends of linear, high density (HD) and long chain branched, low density (LD) polyethylenes indicate that these systems form a one-phase mixture in the melt. However, the maximum spatial resolution of pinhole cameras is approximately equal to 10 3 and it has therefore been suggested that data might also be interpreted as arising from a bi-phasic melt with large a particle size ( 1 m), because most of the scattering from the different phases would not be resolved. We have addressed this hypothesis by means of USANS experiments, which confirm that HDPEILDPE blends are homogenous in the melt on length scales up to 20 m. We have also studied blends of HDPE and short-chain branched linear low density polyethylenes (LLDPEs), which phase separate when the branch content is sufficiently high. LLDPEs prepared with Ziegler-Natta catalysts exhibit a wide distribution of compositions, and may therefore be thought of as a blend of different species. When the composition distribution is broad enough, a fraction of highly branched chains may phase separate on m-length scales, and USANS has also been used to quantify this phenomenon

  8. Comparative analysis of the anterior and posterior length and deflection angle of the cranial base, in individuals with facial Pattern I, II and III

    Directory of Open Access Journals (Sweden)

    Guilherme Thiesen

    2013-02-01

    Full Text Available OBJECTIVE: This study evaluated the variations in the anterior cranial base (S-N, posterior cranial base (S-Ba and deflection of the cranial base (SNBa among three different facial patterns (Pattern I, II and III. METHOD: A sample of 60 lateral cephalometric radiographs of Brazilian Caucasian patients, both genders, between 8 and 17 years of age was selected. The sample was divided into 3 groups (Pattern I, II and III of 20 individuals each. The inclusion criteria for each group were the ANB angle, Wits appraisal and the facial profile angle (G'.Sn.Pg'. To compare the mean values obtained from (SNBa, S-N, S-Ba each group measures, the ANOVA test and Scheffé's Post-Hoc test were applied. RESULTS AND CONCLUSIONS: There was no statistically significant difference for the deflection angle of the cranial base among the different facial patterns (Patterns I, II and III. There was no significant difference for the measures of the anterior and posterior cranial base between the facial Patterns I and II. The mean values for S-Ba were lower in facial Pattern III with statistically significant difference. The mean values of S-N in the facial Pattern III were also reduced, but without showing statistically significant difference. This trend of lower values in the cranial base measurements would explain the maxillary deficiency and/or mandibular prognathism features that characterize the facial Pattern III.OBJETIVO: o presente estudo avaliou as variações da base craniana anterior (S-N, base craniana posterior (S-Ba, e ângulo de deflexão da base do crânio (SNBa entre três diferentes padrões faciais (Padrão I, II e III. MÉTODOS: selecionou-se uma amostra de 60 telerradiografias em norma lateral de pacientes brasileiros leucodermas, de ambos os sexos, com idades entre 8 anos e 17 anos. A amostra foi dividida em três grupos (Padrão I, II e III, sendo cada grupo constituído de 20 indivíduos. Os critérios de seleção dos indivíduos para cada grupo

  9. Studying Soft-matter and Biological Systems over a Wide Length-scale from Nanometer and Micrometer Sizes at the Small-angle Neutron Diffractometer KWS-2

    Science.gov (United States)

    Radulescu, Aurel; Szekely, Noemi Kinga; Appavou, Marie-Sousai; Pipich, Vitaliy; Kohnke, Thomas; Ossovyi, Vladimir; Staringer, Simon; Schneider, Gerald J.; Amann, Matthias; Zhang-Haagen, Bo; Brandl, Georg; Drochner, Matthias; Engels, Ralf; Hanslik, Romuald; Kemmerling, Günter

    2016-01-01

    The KWS-2 SANS diffractometer is dedicated to the investigation of soft matter and biophysical systems covering a wide length scale, from nm to µm. The instrument is optimized for the exploration of the wide momentum transfer Q range between 1x10-4 and 0.5 Å-1 by combining classical pinhole, focusing (with lenses), and time-of-flight (with chopper) methods, while simultaneously providing high-neutron intensities with an adjustable resolution. Because of its ability to adjust the intensity and the resolution within wide limits during the experiment, combined with the possibility to equip specific sample environments and ancillary devices, the KWS-2 shows a high versatility in addressing the broad range of structural and morphological studies in the field. Equilibrium structures can be studied in static measurements, while dynamic and kinetic processes can be investigated over time scales between minutes to tens of milliseconds with time-resolved approaches. Typical systems that are investigated with the KWS-2 cover the range from complex, hierarchical systems that exhibit multiple structural levels (e.g., gels, networks, or macro-aggregates) to small and poorly-scattering systems (e.g., single polymers or proteins in solution). The recent upgrade of the detection system, which enables the detection of count rates in the MHz range, opens new opportunities to study even very small biological morphologies in buffer solution with weak scattering signals close to the buffer scattering level at high Q. In this paper, we provide a protocol to investigate samples with characteristic size levels spanning a wide length scale and exhibiting ordering in the mesoscale structure using KWS-2. We present in detail how to use the multiple working modes that are offered by the instrument and the level of performance that is achieved. PMID:28060296

  10. Development of a molecular-based index for assessing iron status in bloom-forming pennate diatoms.

    Science.gov (United States)

    Marchetti, Adrian; Moreno, Carly M; Cohen, Natalie R; Oleinikov, Irina; deLong, Kimberly; Twining, Benjamin S; Armbrust, E Virginia; Lampe, Robert H

    2017-08-01

    Iron availability limits primary productivity in large areas of the world's oceans. Ascertaining the iron status of phytoplankton is essential for understanding the factors regulating their growth and ecology. We developed an incubation-independent, molecular-based approach to assess the iron nutritional status of specific members of the diatom community, initially focusing on the ecologically important pennate diatom Pseudo-nitzschia. Through a comparative transcriptomic approach, we identified two genes that track the iron status of Pseudo-nitzschia with high fidelity. The first gene, ferritin (FTN), encodes for the highly specialized iron storage protein induced under iron-replete conditions. The second gene, ISIP2a, encodes an iron-concentrating protein induced under iron-limiting conditions. In the oceanic diatom Pseudo-nitzschia granii (Hasle) Hasle, transcript abundance of these genes directly relates to changes in iron availability, with increased FTN transcript abundance under iron-replete conditions and increased ISIP2a transcript abundance under iron-limiting conditions. The resulting ISIP2a:FTN transcript ratio reflects the iron status of cells, where a high ratio indicates iron limitation. Field samples collected from iron grow-out microcosm experiments conducted in low iron waters of the Gulf of Alaska and variable iron waters in the California upwelling zone verify the validity of our proposed Pseudo-nitzschia Iron Limitation Index, which can be used to ascertain in situ iron status and further developed for other ecologically important diatoms. © 2017 Phycological Society of America.

  11. Exact and efficient calculation of Lagrange multipliers in biological polymers with constrained bond lengths and bond angles: proteins and nucleic acids as example cases.

    Science.gov (United States)

    García-Risueño, Pablo; Echenique, Pablo; Alonso, J L

    2011-11-15

    To accelerate molecular dynamics simulations, it is common to impose holonomic constraints on the hardest degrees of freedom. In this way, the time step used to integrate the equations of motion can be increased, thereby allowing longer total simulation times. The imposition of such constraints results in an aditional set of N(c) equations (the equations of constraint) and unknowns (their associated Lagrange multipliers), whose solution is closely related to any algorithm implementing the constraints in Euclidean coordinates. In this work, it is shown that, due to the essentially linear structure of typical biological polymers the algebraic equations that need to be solved involve a matrix which is not only sparse, but also banded if the constraints are indexed in a skilful way. This allows the Lagrange multipliers to be obtained through a noniterative procedure, which can be considered exact up to machine precision, and which takes O(N(c)) operations, instead of the usual O(N c3) for generic molecular systems. We develop the formalism, and describe the appropriate indexing for a number of model molecules. Finally, we provide a numerical example of the technique in a series of polyalanine peptides of different lengths. Although a use of the Lagrange multipliers without any modification in the solution of the underlying ordinary differential equations yields unstable integration algorithms, the central role of these quantities makes their efficient calculation useful for the improvement of methods that correctly enforce the exact satisfaction of the constraints at each time step. We provide several examples of this. Copyright © 2011 Wiley Periodicals, Inc.

  12. 'Length'at Length

    Indian Academy of Sciences (India)

    Admin

    He was interested to know how `large' is the set of numbers x for which the series is convergent. Here large refers to its length. But his set is not in the class ♢. Here is another problem discussed by Borel. Consider .... have an infinite collection of pairs of new shoes and want to choose one shoe from each pair. We have an ...

  13. Tank tests to determine the effect of varying design parameters of planing-tail hulls II : effect of varying depth of step, angle of after- body keel, length of afterbody chine, and gross load

    Science.gov (United States)

    Dawson, John R; Mckann, Robert; Hay, Elizabeth S

    1946-01-01

    The second part of a series of tests made in Langley tank no. 2 to determine the effect of varying design parameters of planing-tail hulls is presented. Results are given to show the effects on resistance characteristics of varying angle of afterbody keel, depth of step, and length of afterbody chine. The effect of varying the gross load is shown for one configuration. The resistance characteristics of planing-tail hulls are compared with those of a conventional flying-boat hull. The forces on the forebody and afterbody of one configuration are compared with the forces on a conventional hull. Increasing the angle of afterbody keel had small effect on hump resistance and no effect on high-speed resistance but increased free-to-trim resistance at intermediate speeds. Increasing the depth of step increased hump resistance, had little effect on high-speed resistance, and increased free-to-trim resistance at intermediate speeds. Omitting the chines on the forward 25 percent of the afterbody had no appreciable effect on resistance. Omitting 70 percent of the chine length had almost no effect on maximum resistance but broadened the hump and increased spray around the afterbody. Load-resistance ratio at the hump decreased more rapidly with increasing load coefficient for the planing-tail hull than for the representative conventional hull, although the load-resistance ratio at the hump was greater for the planing-tail hull than for the conventional hull throughout the range of loads tested. At speeds higher than hump speed, load-resistance ratio for the planing-tail hull was a maximum at a particular gross load and was slightly less at heavier and lighter gross loads. The planing-tail hull was found to have lower resistance than the conventional hull at both the hump and at high speeds, but at intermediate speeds there was little difference. The lower hump resistance of the planing-tail hull was attributed to the ability of the afterbody to carry a greater percentage of the

  14. Neutron small angle scattering

    International Nuclear Information System (INIS)

    Ibel, K.

    1975-01-01

    The neutron small-angle scattering system at the High-Flux Reactor in Grenoble consists of three major parts: the supply of cold neutrons via bent neutron guides; the small angle camera D11; and the data handling facilities. The camera D11 has an overall length of 80 m. The effective length of the camera is variable. The length of the collimator before the fixed sample position can be reduced by movable neutron guides; the secondary flight path of 40 m full length contains detector sites in various positions. Thus, a large domain of momentum transfers can be exploited. Scattering angles between 5.10 -4 and 0.5 rad and neutron wavelengths from 0.2 to 2.0 nm are available with the same instrument and the same relative resolution. A large-area position-sensitive detector is used which allows simultaneous recording of intensities scattered into different angles; it is a multiwire proportional chamber. 3808 elements of 1 cm 2 are arranged in a two-dimensional matrix. Future development comprises an increase of the limit in the count rate due to the electronic interface between the detector and on-line computer, actually at 5.10 4 per sec. by one order of magnitude

  15. Scoliosis angle

    International Nuclear Information System (INIS)

    Marklund, T.

    1978-01-01

    The most commonly used methods of assessing the scoliotic deviation measure angles that are not clearly defined in relation to the anatomy of the patient. In order to give an anatomic basis for such measurements it is proposed to define the scoliotic deviation as the deviation the vertebral column makes with the sagittal plane. Both the Cobb and the Ferguson angles may be based on this definition. The present methods of measurement are then attempts to measure these angles. If the plane of these angles is parallel to the film, the measurement will be correct. Errors in the measurements may be incurred by the projection. A hypothetical projection, called a 'rectified orthogonal projection', is presented, which correctly represents all scoliotic angles in accordance with these principles. It can be constructed in practice with the aid of a computer and by performing measurements on two projections of the vertebral column; a scoliotic curve can be represented independent of the kyphosis and lordosis. (Auth.)

  16. Fundamental length and relativistic length

    International Nuclear Information System (INIS)

    Strel'tsov, V.N.

    1988-01-01

    It si noted that the introduction of fundamental length contradicts the conventional representations concerning the contraction of the longitudinal size of fast-moving objects. The use of the concept of relativistic length and the following ''elongation formula'' permits one to solve this problem

  17. Flame Length

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — Flame length was modeled using FlamMap, an interagency fire behavior mapping and analysis program that computes potential fire behavior characteristics. The tool...

  18. Ribosomal RNA analysis indicates a benthic pennate diatom ancestry for the endosymbionts of the dinoflagellates Peridinium foliaceum and Peridinium balticum (Pyrrhophyta).

    Science.gov (United States)

    Chesnick, J M; Kooistra, W H; Wellbrock, U; Medlin, L K

    1997-01-01

    The establishment of chloroplasts as cellular organelles in the dinoflagellate, heterokont (stramenopile), haptophyte, and cryptophyte algae is widely accepted to have been the result of secondary endosymbiotic events, that is, the uptake of a photosynthetic eukaryote by a phagotrophic eukaryote. However, the circumstances that promote such associations between two phylogenetically distinct organisms and result in the integration of their genomes to form a single functional photosynthetic cell is unclear. The dinoflagellates Peridinium foliaceum and Peridinium balticum are unusual in that each contains a membrane-bound eukaryotic heterokont endosymbiont. These symbioses have been interpreted, through data derived from ultrastructural and biochemical investigations, to represent an intermediate stage of secondary endosymbiotic chloroplast acquisition. In this study we have examined the phylogenetic origin of the P. foliaceum and P. balticum heterokont endosymbionts through analysis of their nuclear small subunit ribosomal RNA genes. Our analyses clearly demonstrate both endosymbionts are pennate diatoms belonging to the family Bacillariaceae. Since members of the Bacillariaceae are usually benthic, living on shallow marine sediments, the manner in which establishment of a symbiosis between a planktonic flagellated dinoflagellate and a bottom-dwelling diatom is discussed. In particular, specific environmentally-associated life strategy stages of the host and symbiont, coupled with diatom food preferences by the dinoflagellate, may have been vital to the formation of this association.

  19. Fundamental length

    International Nuclear Information System (INIS)

    Pradhan, T.

    1975-01-01

    The concept of fundamental length was first put forward by Heisenberg from purely dimensional reasons. From a study of the observed masses of the elementary particles known at that time, it is sumrised that this length should be of the order of magnitude 1 approximately 10 -13 cm. It was Heisenberg's belief that introduction of such a fundamental length would eliminate the divergence difficulties from relativistic quantum field theory by cutting off the high energy regions of the 'proper fields'. Since the divergence difficulties arise primarily due to infinite number of degrees of freedom, one simple remedy would be the introduction of a principle that limits these degrees of freedom by removing the effectiveness of the waves with a frequency exceeding a certain limit without destroying the relativistic invariance of the theory. The principle can be stated as follows: It is in principle impossible to invent an experiment of any kind that will permit a distintion between the positions of two particles at rest, the distance between which is below a certain limit. A more elegant way of introducing fundamental length into quantum theory is through commutation relations between two position operators. In quantum field theory such as quantum electrodynamics, it can be introduced through the commutation relation between two interpolating photon fields (vector potentials). (K.B.)

  20. Tiny incident light angle sensor

    Science.gov (United States)

    Mitrenga, D.; Schädel, M.; Winzer, A. T.; Völlmeke, S.; Preuß, K. D.; Freitag, J.; Brodersen, O.

    2017-05-01

    A novel device for detecting the intensity and the angles of incoming light is presented. The silicon chip with 1 mm edge length comprises a segmented photo diode with four active areas within the inclined surfaces of a deep etched cavity. Simple signal difference analysis of these signals allow for accurate azimuth and inclination measurement in the range of 0 to 360° and 0 to 55°, respectively. Using an artificial neural network (ANN) calibration strategy the operation range of inclination can be increased up to 85° with typical angle errors below 2°. In this report we present details on design, fabrication, signal analysis and calibration strategies.

  1. Small angle neutron scattering

    International Nuclear Information System (INIS)

    Dasannacharya, B.A.; Goyal, P.S.

    1997-01-01

    Small angle neutron scattering (SANS) is one of the most popular neutron scattering technique both for the basic research and as a tool in the hands of applied scientist. SANS is used for studying the structure of a material on a length scale of 10 - 1000 A. SANS is a diffraction experiment that involves scattering of a monocromatic beam of neutrons in order to obtain structural information about macromolecules and heterogeneities. This paper will discuss the design of SANS spectrometers with a special emphasis on the instruments which are better suited for medium flux reactors. The design of several different types of SANS spectrometers will be given. The optimization procedures and appropriate modifications to suit the budget and the space will be discussed. As an example, the design of a SANS spectrometer at CIRUS reactor Trombay will be given. (author)

  2. Small-angle scattering on soft materials

    International Nuclear Information System (INIS)

    Mortensen, K.

    1994-01-01

    Small angle x-ray and neutron scattering provides tools for investigation of structures on the length scale 10 to 1000 A. This is the length scale which is relevant for many topics within soft materials, like biological macromolecules, polymers, colloids, etc. The very large difference between the scattering amplitude of neutrons by regular hydrogen and deuterium makes neutron scattering a very important technique within soft condensed matter. The basic theory for small angle scattering is reviewed. Experimental results obtained by small angle scattering are shown, with emphasis on soft materials. (author). 33 refs, 6 figs, 1 tab

  3. O comprimento dos túneis femorais varia com a flexão do joelho na reconstrução anatômica do ligamento cruzado anterior Femoral tunnels' length changes with knee flexion angle in anatomical anterior cruciate ligament reconstruction

    Directory of Open Access Journals (Sweden)

    Julio Cesar Gali

    2012-04-01

    Full Text Available OBJETIVO: O propósito de nosso trabalho foi avaliar o efeito que o grau de flexão do joelho, durante a perfuração dos túneis femorais, pode causar no comprimento desses túneis, na reconstrução anatômica do ligamento cruzado anterior. MÉTODOS: Medimos o comprimento dos túneis femorais anteromedial e posterolateral do ligamento cruzado anterior, em 20 peças anatômicas de joelhos desemparelhadas, 10 direitas e 10 esquerdas, todas com a cartilagem e ligamentos cruzados íntegros. Os túneis foram perfurados com os joelhos flexionados a 90, 110 e 130 graus de flexão, através do portal anteromedial acessório, com uma broca de 2,5mm. Os estudos estatísticos foram realizadas pela análise de variância de Friedman e pelo teste de Mann-Whitney. RESULTADO: A média dos comprimentos dos túneis femorais anteromediais medidos com os joelhos flexionados a 90, 110 e 130 graus foram 33,7 ± 3,72mm, 37,4 ± 2,93mm e 38,8 ± 3,31mm, respectivamente. Para o comprimento dos túneis posterolaterais, os resultados obtidos a 90, 110 e 130 graus foram 32,1 ± 4,24mm, 37,3 ± 4,85mm e 38,4 ± 2,51mm, respectivamente. A análise de variância de Friedman mostrou diferença significativa entre os comprimentos dos túneis perfurados com 90 e 110 graus de flexão das peças, porém não mostrou diferença significativa entre os obtidos com flexão de 110e 130 graus (p OBJECTIVE: The objective of our study was to evaluate the effect that knee flexion angle while femoral tunnels are being drilled may have on the length of these tunnels, in anatomical reconstruction of the anterior cruciate ligament. METHODS: We measured the lengths of anteromedial and posterolateral tunnels for the anterior cruciate ligament in 20 unpaired anatomical knee specimens (10 right and 10 left knees, all with the cartilage and cruciate ligaments intact. Tunnels were drilled with the knees flexed at 90º, 110º and 130º, through the accessory anteromedial portal, with a 2.5 mm

  4. Radiographic assessment of endodontic working length

    OpenAIRE

    Osama S Alothmani; Lara T Friedlander; Nicholas P Chandler

    2013-01-01

    The use of radiographs for working length determination is usual practice in endodontics. Exposing radiographs following the principles of the paralleling technique allows more accurate length determination compared to the bisecting-angle method. However, it has been reported that up to 28.5% of cases can have the file tip extending beyond the confines of the root canals despite an acceptable radiographic appearance. The accuracy of radiographic working length determination could be affected ...

  5. Comparative biometric study between plateau iris configuration and primary open angle glaucoma with narrow angle.

    Science.gov (United States)

    Diniz Filho, Alberto; Cronemberger, Sebastião; Mérula, Rafael Vidal; Calixto, Nassim

    2009-01-01

    To investigate biometrically the differences between plateau iris configuration (PIC) eyes and primary open angle glaucoma with narrow angle eyes. A comparative study involving a case series with 20 eyes of 11 plateau iris configuration patients and 45 eyes of 27 primary open angle glaucoma with narrow angle eyes patients was done. The following measurements were taken: corneal curvature, central corneal thickness, anterior chamber depth, lens thickness (LT), axial length (AL), lens thickness and axial length ratio, lens position (LP) and relative lens position (RLP). The plateau iris configuration eyes presented a higher corneal cuvature value than primary open angle glaucoma with narrow angle eyes eyes but not with clinical and statistical difference (P=0.090). The plateau iris configuration eyes demonstrated a higher central corneal thickness, with statistical significance, when compared to primary open angle glaucoma with narrow angle eyes (P=0.010). Statistical significant difference between plateau iris configuration and primary open angle glaucoma with narrow angle eyes was found in axial length (21.69 +/- 0.98 vs. 22.42 +/- 0.89; P=0.003). No significant difference was found when anterior chamber depth (2.62 +/- 0.23 vs. 2.71 +/- 0.31; P=0.078), LT (4.67 +/- 0.36 vs. 4.69 +/- 0.45; P=0.975), LT/AL (2.16 +/- 0.17 vs. 2.10 +/- 0.21; P=0.569), LP (4.95 +/- 0.25 vs. 5.06 +/- 0.34; P=0.164) and RLP (0.23 +/- 0.01 vs. 0.22 +/- 0.14; P=0.348) were evaluated. The eyes with plateau iris configuration presented statistical significantly shorter axial length and higher central corneal thickness than primary open angle glaucoma with narrow angle eyes.

  6. Ocular biometry in angle closure.

    Science.gov (United States)

    Razeghinejad, Mohammad Reza; Banifatemi, Mohammad

    2013-01-01

    To compare ocular biometric parameters in primary angle closure suspects (PACS), primary angle closure glaucoma (PACG) and acute primary angle closure (APAC). This cross-sectional study was performed on 113 patients including 33 cases of PACS, 45 patients with PACG and 35 subjects with APAC. Central corneal thickness (CCT), axial length (AL), anterior chamber depth (ACD) and lens thickness (LT) were measured with an ultrasonic biometer. Lens-axial length factor (LAF), relative lens position, corrected ACD (CACD) and corrected lens position were calculated. The parameters were measured bilaterally but only data from the right eyes were compared. In the APAC group, biometric parameters were also compared between affected and unaffected fellow eyes. Logistic regression analysis was performed to identify risk factors. No statistically significant difference was observed in biometric parameters between PACS and PACG eyes, or between affected and fellow eyes in the APAC group (P>0.05 for all comparisons). However, eyes with APAC had thicker cornea (P=0.001), thicker lens (PAPAC. In the APAC group, LAF (PAPAC.

  7. Contact Angle Goniometer

    Data.gov (United States)

    Federal Laboratory Consortium — Description:The FTA32 goniometer provides video-based contact angle and surface tension measurement. Contact angles are measured by fitting a mathematical expression...

  8. The HBN Angle

    Directory of Open Access Journals (Sweden)

    Harsh Bhagvatiprasad Dave

    2015-01-01

    Full Text Available Aim: The purpose of this study was to establish a new cephalometric measurement, named the Harsh Bhagvatiprasad Nita angle (HBN, to assess the sagittal jaw relationship with accuracy and reproducibility. Materials and Methods: Three hundred pretreatment lateral cephalograms (100 each of Class I, II, and III were taken from the Department of Orthodontics and Dentofacial Orthopedics of Rajasthan Dental College and Hospital, Jaipur (Rajasthan and were subdivided into skeletal Class I, II, and III based on ANB, Wits appraisal, and Beta angle. This angle uses 3 skeletal landmarks the "C" (apparent axis of the condyle, "M" (midpoint of the premaxilla, and "G" (center of the largest circle that is tangent to the internal inferior, anterior, and posterior surfaces of the mandibular symphysis. Results: The result of the mean and standard deviation for the HBN angle were calculated in all three skeletal groups. After using one-way analysis of variance and post-hoc multiple comparisons by using Tukey′s honestly significant difference, homogeneous subsets, receiver operating characteristics (ROC curve - to differentiate Class II with Class I, ROC curve - to differentiate Class III with Class I, Reliability analysis with interclass correlation of HBN angle with other angles, we obtained results that showed that a patient with a HBN angle 40° and 46° can be considered to have a Class I skeletal pattern. Conclusions: A new angle, the HBN angle, was developed as a diagnostic aid to evaluate the sagittal jaw relationship more consistently. HBN angle 40° and 46° can be considered to have a Class I skeletal pattern, a more acute HBN angle indicates a Class II skeletal pattern, and a more obtuse HBN angle indicates a Class III skeletal pattern.

  9. On the dip angle of subducting plates

    Science.gov (United States)

    Hsui, Albert T.; Tang, Xiao-Ming; Toksoz, M. Nafi

    1990-01-01

    A new approximate analytic model is developed for the thermal structure of a subducting plate with a finite length. This model provides the capability of easily examining the thermal and mechanical structure of a subducting plate with different lengths and at different angles. Also, the torque balance of a descending plate can be examined, and effects such as the leading edge effect, the adiabatic compression effect, and the phase change effect can be incorporated. A comparison with observed data indicates that short slabs are likely under torque equilibrium at present, while long slabs are probably dominated by their gravitational torques such that their dip angles are transient, moving toward a steeper dip angle similar to that of the Mariana slab.

  10. Ocular Biometry in Angle Closure

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Razeghinejad

    2013-01-01

    Full Text Available Purpose: To compare ocular biometric parameters in primary angle closure suspects (PACS, primary angle closure glaucoma (PACG and acute primary angle closure (APAC. Methods: This cross-sectional study was performed on 113 patients including 33 cases of PACS, 45 patients with PACG and 35 subjects with APAC. Central corneal thickness (CCT, axial length (AL, anterior chamber depth (ACD and lens thickness (LT were measured with an ultrasonic biometer. Lens-axial length factor (LAF, relative lens position, corrected ACD (CACD and corrected lens position were calculated. The parameters were measured bilaterally but only data from the right eyes were compared. In the APAC group, biometric parameters were also compared between affected and unaffected fellow eyes. Logistic regression analysis was performed to identify risk factors. Results: No statistically significant difference was observed in biometric parameters between PACS and PACG eyes, or between affected and fellow eyes in the APAC group (P>0.05 for all comparisons. However, eyes with APAC had thicker cornea (P=0.001, thicker lens (P<0.0001, shallower ACD (P=0.009, shallower CACD (P=0.003 and larger LAF (P<0.0001. Based on ROC curve analysis, lower ACD, and larger LT, LAF and CCT values were associated with APAC. In the APAC group, LAF (P<0.0001 and CCT (P=0.001 were significant risk factors. Conclusion: This study revealed no significant difference in biometric characteristics in eyes with PACS and PACG. However, larger LAF and CCT were predictive of APAC.

  11. Reading Angles in Maps

    Science.gov (United States)

    Izard, Véronique; O'Donnell, Evan; Spelke, Elizabeth S.

    2014-01-01

    Preschool children can navigate by simple geometric maps of the environment, but the nature of the geometric relations they use in map reading remains unclear. Here, children were tested specifically on their sensitivity to angle. Forty-eight children (age 47:15-53:30 months) were presented with fragments of geometric maps, in which angle sections…

  12. Optimal reconstruction angles

    International Nuclear Information System (INIS)

    Cook, G.O. Jr.; Knight, L.

    1979-07-01

    The question of optimal projection angles has recently become of interest in the field of reconstruction from projections. Here, studies are concentrated on the n x n pixel space, where literative algorithms such as ART and direct matrix techniques due to Katz are considered. The best angles are determined in a Gauss--Markov statistical sense as well as with respect to a function-theoretical error bound. The possibility of making photon intensity a function of angle is also examined. Finally, the best angles to use in an ART-like algorithm are studied. A certain set of unequally spaced angles was found to be preferred in several contexts. 15 figures, 6 tables

  13. Radiographic assessment of endodontic working length

    Directory of Open Access Journals (Sweden)

    Osama S Alothmani

    2013-01-01

    Full Text Available The use of radiographs for working length determination is usual practice in endodontics. Exposing radiographs following the principles of the paralleling technique allows more accurate length determination compared to the bisecting-angle method. However, it has been reported that up to 28.5% of cases can have the file tip extending beyond the confines of the root canals despite an acceptable radiographic appearance. The accuracy of radiographic working length determination could be affected by the location of the apical foramen, tooth type, canal curvature and superimposition of surrounding structures. Variations among observers by virtue of training and experience may also influence the accuracy of the procedure. The interpretation of radiographs could be affected by film speed and viewing conditions, with the superiority of digital imaging over conventional radiography for working length determination remaining debatable. The combination of several methods is recommended for acquiring the most accurate working length.

  14. Comparison of Anterior Segment-Optical Coherence Tomography Parameters in Phacomorphic Angle Closure and Acute Angle Closure Eyes.

    Science.gov (United States)

    Moghimi, Sasan; Ramezani, Farshid; He, Mingguang; Coleman, Anne L; Lin, Shan C

    2015-12-01

    The purpose of this study is to compare anterior segment-optical coherence tomography (AS-OCT) parameters in phacomorphic angle closure and acute primary angle closure (APAC) eyes. In this cross-sectional case series, a total of 134 patients with phacomorphic angle closure (28 eyes) or APAC (54 eyes), as well as normal control subjects (52 eyes), were enrolled. Patients underwent AS-OCT imaging and A-scan biometry of both eyes. Anterior chamber depth (ACD), anterior chamber area (ACA), iris thickness (IT), iris curvature, lens vault (LV), anterior vault (AV), and angle parameters including angle opening distance (AOD 500 and AOD750) and trabecular iris space area (TISA500 and TISA750) were measured in qualified images using the Zhongshan Angle Assessment Program and compared among eyes with phacomorphic angle closure, APAC, and normal control subjects. Phacomorphic angle closure and APAC eyes had smaller AOD, ACD, ACA, ACW, AV, and posterior corneal arc length and greater LV than normal controls (P APAC eyes: ACD 1042 μm (OR,12.12; P APAC eyes. In multivariate analysis, ACD, LV, AOD500, and axial length could significantly distinguish the two entities. Ocular biometric parameters can differentiate phacomorphic angle closure from APAC eyes. Shallower ACD and greater LV, axial length, and ACA are the main parameters that distinguish phacomorphic angle closure from APAC.

  15. Photoelectric angle converter

    Science.gov (United States)

    Podzharenko, Volodymyr A.; Kulakov, Pavlo I.

    2001-06-01

    The photo-electric angle transmitter of rotation is offered, at which the output voltage is linear function of entering magnitude. In a transmitter the linear phototransducer is used on the basis of pair photo diode -- operating amplifier, which output voltage is linear function of the area of an illuminated photosensitive stratum, and modulator of a light stream of the special shape, which ensures a linear dependence of this area from an angle of rotation. The transmitter has good frequent properties and can be used for dynamic measurements of an angular velocity and angle of rotation, in systems of exact drives and systems of autocontrol.

  16. Angles in hyperbolic lattices

    DEFF Research Database (Denmark)

    Risager, Morten S.; Södergren, Carl Anders

    2017-01-01

    It is well known that the angles in a lattice acting on hyperbolic n -space become equidistributed. In this paper we determine a formula for the pair correlation density for angles in such hyperbolic lattices. Using this formula we determine, among other things, the asymptotic behavior of the den......It is well known that the angles in a lattice acting on hyperbolic n -space become equidistributed. In this paper we determine a formula for the pair correlation density for angles in such hyperbolic lattices. Using this formula we determine, among other things, the asymptotic behavior...... of the density function in both the small and large variable limits. This extends earlier results by Boca, Pasol, Popa and Zaharescu and Kelmer and Kontorovich in dimension 2 to general dimension n . Our proofs use the decay of matrix coefficients together with a number of careful estimates, and lead...

  17. Characterization of porous materials by small-angle scattering

    Indian Academy of Sciences (India)

    With the availability of ultra small-angle scattering instru- ments, one can investigate porous materials in the sub-micron length scale. Because of the increased accessible length scale vis-a-vis the multiple scattering effect, conventional data analysis procedures based on single scattering approximation quite often fail. The.

  18. Characterization of porous materials by small-angle scattering

    Indian Academy of Sciences (India)

    With the availability of ultra small-angle scattering instruments, one can investigate porous materials in the sub-micron length scale. Because of the increased accessible length scale vis-a-vis the multiple scattering effect, conventional data analysis procedures based on single scattering approximation quite often fail.

  19. Fibre operating lengths of human lower limb muscles during walking.

    Science.gov (United States)

    Arnold, Edith M; Delp, Scott L

    2011-05-27

    Muscles actuate movement by generating forces. The forces generated by muscles are highly dependent on their fibre lengths, yet it is difficult to measure the lengths over which muscle fibres operate during movement. We combined experimental measurements of joint angles and muscle activation patterns during walking with a musculoskeletal model that captures the relationships between muscle fibre lengths, joint angles and muscle activations for muscles of the lower limb. We used this musculoskeletal model to produce a simulation of muscle-tendon dynamics during walking and calculated fibre operating lengths (i.e. the length of muscle fibres relative to their optimal fibre length) for 17 lower limb muscles. Our results indicate that when musculotendon compliance is low, the muscle fibre operating length is determined predominantly by the joint angles and muscle moment arms. If musculotendon compliance is high, muscle fibre operating length is more dependent on activation level and force-length-velocity effects. We found that muscles operate on multiple limbs of the force-length curve (i.e. ascending, plateau and descending limbs) during the gait cycle, but are active within a smaller portion of their total operating range.

  20. Changes in the foot angle after calcaneal fractures

    International Nuclear Information System (INIS)

    Frahm, R.; Fritz, H.; Drescher, E.

    1989-01-01

    Forty fractured calcanei (13 without and 27 with involvement of the joint) were examined by CT and the angle of the hind foot measured. Following a typical compression fracture there is a negative calcaneusvalgus angle, i.e. varus deformity of the tuberosity fragment. The sustentaculum angle is increased. There are changes in the talo-calcaneal and calcaneo-cuboidal angles. The length ratio of calcaneus to talus is reduced. Reproducible measurements make it possible to compare the results of operative correction and of changes in shape following conservative treatment, e.g. during weight-bearing. (orig.) [de

  1. Telomere length analysis.

    Science.gov (United States)

    Canela, Andrés; Klatt, Peter; Blasco, María A

    2007-01-01

    Most somatic cells of long-lived species undergo telomere shortening throughout life. Critically short telomeres trigger loss of cell viability in tissues, which has been related to alteration of tissue function and loss of regenerative capabilities in aging and aging-related diseases. Hence, telomere length is an important biomarker for aging and can be used in the prognosis of aging diseases. These facts highlight the importance of developing methods for telomere length determination that can be employed to evaluate telomere length during the human aging process. Telomere length quantification methods have improved greatly in accuracy and sensitivity since the development of the conventional telomeric Southern blot. Here, we describe the different methodologies recently developed for telomere length quantification, as well as their potential applications for human aging studies.

  2. open angle glaucoma (poag)?

    African Journals Online (AJOL)

    there is a build up of pressure due to poor outflow of aqueous humor. The outflow obstruction could occur at the trabecular meshwork of the anterior chamber angle or subsequently in the episcleral vein due to raised venous pressure. Such build up of pressure results in glaucoma . Elevated intraocular pressure remains the ...

  3. The quadriceps angle

    DEFF Research Database (Denmark)

    Miles, James Edward; Frederiksen, Jane V.; Jensen, Bente Rona

    2012-01-01

    : Pelvic limbs from red foxes (Vulpes vulpes). METHODS: Q angles were measured on hip dysplasia (HD) and whole limb (WL) view radiographs of each limb between the acetabular rim, mid-point (Q1: patellar center, Q2: femoral trochlea), and tibial tuberosity. Errors of 0.5-2.0 mm at measurement landmarks...

  4. At Right Angles

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 17; Issue 9. At Right Angles. Shailesh A Shirali. Information and Announcements Volume 17 Issue 9 September 2012 pp 920-920. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/017/09/0920-0920 ...

  5. The lateral angle revisited

    DEFF Research Database (Denmark)

    Morgan, Jeannie; Lynnerup, Niels; Hoppa, R.D.

    2013-01-01

    This article presents the results of a validation study of a previously published method of sex determination from the temporal bone. The purpose of this study was to evaluate the lateral angle method for the internal acoustic canal for accurately determining the sex of human skeletal remains usi...... method appears to be of minimal practical use in forensic anthropology and archeology....

  6. Small angle neutron scattering

    International Nuclear Information System (INIS)

    Gupta, Sanjay

    1982-01-01

    The technique of small angle neutron scattering was first used in Germany less than two decades ago. Since then it has developed very rapidly, and today it is regarded as one of the most powerful techniques in materials, chemical and biological research. During the last decade the combination of high flux reactors and sophisticated instrumentation has revolutionized the technique. This paper endeavours to present a brief but comprehensive review of small angle scattering of neutrons and its applications in solid state research. The domain in which small angle neutron scattering is particularly useful is delineated and some of the methods used in the analysis of data are discussed with special emphasis on recent developments. Typical small angle neutron scattering cameras are described. Finally some experimental results on heterogeneities in metallic systems (both static and dynamic studies), radiation damage in materials, superconductivity, magnetic materials and the technologically very important area of non-destructive testing are reviewed in order to illustrate the wide range of applicability of this technique to problems in solid state research. (author)

  7. At Right Angles

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 17; Issue 9. At Right Angles. Shailesh A Shirali. Information and Announcements Volume 17 Issue 9 September 2012 pp 920-920. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/017/09/0920-0920 ...

  8. Telomere length and depression

    DEFF Research Database (Denmark)

    Wium-Andersen, Marie Kim; Ørsted, David Dynnes; Rode, Line

    2017-01-01

    BACKGROUND: Depression has been cross-sectionally associated with short telomeres as a measure of biological age. However, the direction and nature of the association is currently unclear. AIMS: We examined whether short telomere length is associated with depression cross-sectionally as well...... as prospectively and genetically. METHOD: Telomere length and three polymorphisms, TERT, TERC and OBFC1, were measured in 67 306 individuals aged 20-100 years from the Danish general population and associated with register-based attendance at hospital for depression and purchase of antidepressant medication....... RESULTS: Attendance at hospital for depression was associated with short telomere length cross-sectionally, but not prospectively. Further, purchase of antidepressant medication was not associated with short telomere length cross-sectionally or prospectively. Mean follow-up was 7.6 years (range 0...

  9. Myofilament length dependent activation

    Energy Technology Data Exchange (ETDEWEB)

    de Tombe, Pieter P.; Mateja, Ryan D.; Tachampa, Kittipong; Mou, Younss Ait; Farman, Gerrie P.; Irving, Thomas C. (IIT); (Loyola)

    2010-05-25

    The Frank-Starling law of the heart describes the interrelationship between end-diastolic volume and cardiac ejection volume, a regulatory system that operates on a beat-to-beat basis. The main cellular mechanism that underlies this phenomenon is an increase in the responsiveness of cardiac myofilaments to activating Ca{sup 2+} ions at a longer sarcomere length, commonly referred to as myofilament length-dependent activation. This review focuses on what molecular mechanisms may underlie myofilament length dependency. Specifically, the roles of inter-filament spacing, thick and thin filament based regulation, as well as sarcomeric regulatory proteins are discussed. Although the 'Frank-Starling law of the heart' constitutes a fundamental cardiac property that has been appreciated for well over a century, it is still not known in muscle how the contractile apparatus transduces the information concerning sarcomere length to modulate ventricular pressure development.

  10. Upper Extremity Length Equalization

    OpenAIRE

    DeCoster, Thomas A.; Ritterbusch, John; Crawford, Mark

    1992-01-01

    Significant upper extremity length inequality is uncommon but can cause major functional problems. The ability to position and use the hand may be impaired by shortness of any of the long bones of the upper extremity. In many respects upper and lower extremity length problems are similar. They most commonly occur after injury to a growing bone and the treatment modalities utilized in the lower extremity may be applied to the upper extremity. These treatment options include epiphysiodesis, sho...

  11. Relativistic Length Agony Continued

    Science.gov (United States)

    Redzic, D. V.

    2014-06-01

    We made an attempt to remedy recent confusing treatments of some basic relativistic concepts and results. Following the argument presented in an earlier paper (Redzic 2008b), we discussed the misconceptions that are recurrent points in the literature devoted to teaching relativity such as: there is no change in the object in Special Relativity, illusory character of relativistic length contraction, stresses and strains induced by Lorentz contraction, and related issues. We gave several examples of the traps of everyday language that lurk in Special Relativity. To remove a possible conceptual and terminological muddle, we made a distinction between the relativistic length reduction and relativistic FitzGerald-Lorentz contraction, corresponding to a passive and an active aspect of length contraction, respectively; we pointed out that both aspects have fundamental dynamical contents. As an illustration of our considerations, we discussed briefly the Dewan-Beran-Bell spaceship paradox and the 'pole in a barn' paradox.

  12. Telomere Length and Mortality

    DEFF Research Database (Denmark)

    Kimura, Masayuki; Hjelmborg, Jacob V B; Gardner, Jeffrey P

    2008-01-01

    Leukocyte telomere length, representing the mean length of all telomeres in leukocytes, is ostensibly a bioindicator of human aging. The authors hypothesized that shorter telomeres might forecast imminent mortality in elderly people better than leukocyte telomere length. They performed mortality...... telomeres predicted the death of the first co-twin better than the mTRFL did (mTRFL: 0.56, 95% confidence interval (CI): 0.49, 0.63; mTRFL(50): 0.59, 95% CI: 0.52, 0.66; mTRFL(25): 0.59, 95% CI: 0.52, 0.66; MTRFL: 0.60, 95% CI: 0.53, 0.67). The telomere-mortality association was stronger in years 3-4 than...

  13. Relationship between the angle of repose and angle of internal ...

    African Journals Online (AJOL)

    Abstract. Click on the link to view the abstract. Keywords: Angle of repose, angle of internal friction, granular materials, triaxial compression machine, moisture content. Tanzania J. Agric. Sc. (1998) Vol.1 No.2, 187-194 ...

  14. Full Length Research Article

    African Journals Online (AJOL)

    Administrator

    Out of the 320 male sheep examined, 87(27.2%) were infected, while 9(19.1%) of the 47 females examined were infected (Table 2). Infection varied from one abattoir to another. Age related distribution of P. cervi is shown in Table 3. Out of 356 adult sheep (>2yrs) examined, 35. Full Length Research Article. 12 ...

  15. Critical angle laser refractometer

    International Nuclear Information System (INIS)

    Castrejon-Pita, J.R.; Morales, A.; Castrejon-Garcia, R.

    2006-01-01

    A simple laser refractometer based on the detection of the critical angle for liquids is presented. The calibrated refractometer presents up to 0.000 11 of uncertainty when the refractive index is in the range between 1.300 00 and 1.340 00. The experimental setup is easy to construct and the material needed is available at most optics laboratories. The calibration method is simple and can be used in other devices. The refractive index measurements in aqueous solutions of sodium chloride were carried out to test the device and a linear dependence between the refractive index and the salt concentration was found

  16. In vivo measurements of the triceps surae complex architecture in man: implications for muscle function

    NARCIS (Netherlands)

    Maganaris, C.N.; Baltzopoulos, V.; Sargeant, A.J.

    1998-01-01

    1. The objectives of this study were to (1) quantify experimentally in vivo changes in pennation angle, fibre length and muscle thickness in the triceps surae complex in man in response to changes in ankle position and isometric plantarflexion moment and (2) compare changes in the above muscle

  17. Scaling of misorientation angle distributions

    DEFF Research Database (Denmark)

    Hughes, D.A.; Chrzan, D.C.; Liu, Q.

    1998-01-01

    The measurement of misorientation angle distributions following different amounts of deformation in cold-rolled aluminum and nickel and compressed stainless steel is reported. The sealing of the dislocation cell boundary misorientation angle distributions is studied. Surprisingly, the distributio...

  18. Angle performance on optima MDxt

    Energy Technology Data Exchange (ETDEWEB)

    David, Jonathan; Kamenitsa, Dennis [Axcelis Technologies, Inc., 108 Cherry Hill Dr, Beverly, MA 01915 (United States)

    2012-11-06

    Angle control on medium current implanters is important due to the high angle-sensitivity of typical medium current implants, such as halo implants. On the Optima MDxt, beam-to-wafer angles are controlled in both the horizontal and vertical directions. In the horizontal direction, the beam angle is measured through six narrow slits, and any angle adjustment is made by electrostatically steering the beam, while cross-wafer beam parallelism is adjusted by changing the focus of the electrostatic parallelizing lens (P-lens). In the vertical direction, the beam angle is measured through a high aspect ratio mask, and any angle adjustment is made by slightly tilting the wafer platen prior to implant. A variety of tests were run to measure the accuracy and repeatability of Optima MDxt's angle control. SIMS profiles of a high energy, channeling sensitive condition show both the cross-wafer angle uniformity, along with the small-angle resolution of the system. Angle repeatability was quantified by running a channeling sensitive implant as a regular monitor over a seven month period and measuring the sheet resistance-to-angle sensitivity. Even though crystal cut error was not controlled for in this case, when attributing all Rs variation to angle changes, the overall angle repeatability was measured as 0.16 Degree-Sign (1{sigma}). A separate angle repeatability test involved running a series of V-curves tests over a four month period using low crystal cut wafers selected from the same boule. The results of this test showed the angle repeatability to be <0.1 Degree-Sign (1{sigma}).

  19. Variable angle correlation spectroscopy

    International Nuclear Information System (INIS)

    Lee, Y.K.; Lawrence Berkeley Lab., CA

    1994-05-01

    In this dissertation, a novel nuclear magnetic resonance (NMR) technique, variable angle correlation spectroscopy (VACSY) is described and demonstrated with 13 C nuclei in rapidly rotating samples. These experiments focus on one of the basic problems in solid state NMR: how to extract the wealth of information contained in the anisotropic component of the NMR signal while still maintaining spectral resolution. Analysis of the anisotropic spectral patterns from poly-crystalline systems reveal information concerning molecular structure and dynamics, yet in all but the simplest of systems, the overlap of spectral patterns from chemically distinct sites renders the spectral analysis difficult if not impossible. One solution to this problem is to perform multi-dimensional experiments where the high-resolution, isotropic spectrum in one dimension is correlated with the anisotropic spectral patterns in the other dimensions. The VACSY technique incorporates the angle between the spinner axis and the static magnetic field as an experimental parameter that may be incremented during the course of the experiment to help correlate the isotropic and anisotropic components of the spectrum. The two-dimensional version of the VACSY experiments is used to extract the chemical shift anisotropy tensor values from multi-site organic molecules, study molecular dynamics in the intermediate time regime, and to examine the ordering properties of partially oriented samples. The VACSY technique is then extended to three-dimensional experiments to study slow molecular reorientations in a multi-site polymer system

  20. Variable angle correlation spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Kyo [Univ. of California, Berkeley, CA (United States)

    1994-05-01

    In this dissertation, a novel nuclear magnetic resonance (NMR) technique, variable angle correlation spectroscopy (VACSY) is described and demonstrated with 13C nuclei in rapidly rotating samples. These experiments focus on one of the basic problems in solid state NMR: how to extract the wealth of information contained in the anisotropic component of the NMR signal while still maintaining spectral resolution. Analysis of the anisotropic spectral patterns from poly-crystalline systems reveal information concerning molecular structure and dynamics, yet in all but the simplest of systems, the overlap of spectral patterns from chemically distinct sites renders the spectral analysis difficult if not impossible. One solution to this problem is to perform multi-dimensional experiments where the high-resolution, isotropic spectrum in one dimension is correlated with the anisotropic spectral patterns in the other dimensions. The VACSY technique incorporates the angle between the spinner axis and the static magnetic field as an experimental parameter that may be incremented during the course of the experiment to help correlate the isotropic and anisotropic components of the spectrum. The two-dimensional version of the VACSY experiments is used to extract the chemical shift anisotropy tensor values from multi-site organic molecules, study molecular dynamics in the intermediate time regime, and to examine the ordering properties of partially oriented samples. The VACSY technique is then extended to three-dimensional experiments to study slow molecular reorientations in a multi-site polymer system.

  1. Gap length distributions by PEPR

    International Nuclear Information System (INIS)

    Warszawer, T.N.

    1980-01-01

    Conditions guaranteeing exponential gap length distributions are formulated and discussed. Exponential gap length distributions of bubble chamber tracks first obtained on a CRT device are presented. Distributions of resulting average gap lengths and their velocity dependence are discussed. (orig.)

  2. Length of excitable knots

    Science.gov (United States)

    Maucher, Fabian; Sutcliffe, Paul

    2017-07-01

    In this paper, we present extensive numerical simulations of an excitable medium to study the long-term dynamics of knotted vortex strings for all torus knots up to crossing number 11. We demonstrate that FitzHugh-Nagumo evolution preserves the knot topology for all the examples presented, thereby providing a field theory approach to the study of knots. Furthermore, the evolution yields a well-defined minimal length for each knot that is comparable to the ropelength of ideal knots. We highlight the role of the medium boundary in stabilizing the length of the knot and discuss the implications beyond torus knots. We also show that there is not a unique attractor within a given knot topology.

  3. Pion nucleus scattering lengths

    International Nuclear Information System (INIS)

    Huang, W.T.; Levinson, C.A.; Banerjee, M.K.

    1971-09-01

    Soft pion theory and the Fubini-Furlan mass dispersion relations have been used to analyze the pion nucleon scattering lengths and obtain a value for the sigma commutator term. With this value and using the same principles, scattering lengths have been predicted for nuclei with mass number ranging from 6 to 23. Agreement with experiment is very good. For those who believe in the Gell-Mann-Levy sigma model, the evaluation of the commutator yields the value 0.26(m/sub σ//m/sub π/) 2 for the sigma nucleon coupling constant. The large dispersive corrections for the isosymmetric case implies that the basic idea behind many of the soft pion calculations, namely, slow variation of matrix elements from the soft pion limit to the physical pion mass, is not correct. 11 refs., 1 fig., 3 tabs

  4. Length-weight and length-length relationships of freshwater wild ...

    African Journals Online (AJOL)

    Length-weight and length-length relationships of freshwater wild catfish Mystus bleekeri from Nala Daik, Sialkot, Pakistan. ... Linear regression analysis was used, first to compute the degree of relationship between length and weight and then among total (TL), standard (SL) and fork lengths (FL). LWR exhibited a highly ...

  5. Relativistic length agony continued

    Directory of Open Access Journals (Sweden)

    Redžić D.V.

    2014-01-01

    Full Text Available We made an attempt to remedy recent confusing treatments of some basic relativistic concepts and results. Following the argument presented in an earlier paper (Redžić 2008b, we discussed the misconceptions that are recurrent points in the literature devoted to teaching relativity such as: there is no change in the object in Special Relativity, illusory character of relativistic length contraction, stresses and strains induced by Lorentz contraction, and related issues. We gave several examples of the traps of everyday language that lurk in Special Relativity. To remove a possible conceptual and terminological muddle, we made a distinction between the relativistic length reduction and relativistic FitzGerald-Lorentz contraction, corresponding to a passive and an active aspect of length contraction, respectively; we pointed out that both aspects have fundamental dynamical contents. As an illustration of our considerations, we discussed briefly the Dewan-Beran-Bell spaceship paradox and the ‘pole in a barn’ paradox. [Projekat Ministarstva nauke Republike Srbije, br. 171028

  6. [3-dimensional CT cephalometry before and after mandibular angle osteotomy and its clinical significance].

    Science.gov (United States)

    Li, Hui-Chao; Li, Dong-Mei; Zhang, Zhi-Yong; Lü, Chang-Sheng; Liu, Yu-Feng; Zhang, Ji; Gui, Lai

    2008-05-01

    To investigate the change of skeleton structure and masseter after mandibular angle osteotomy and its clinical significance in preoperative design. 3-dimensional CT cephalometry was performed before and after surgery in 18 cases of prominent mandibular angle. Pre- and post-operative data were compared. Significant differences between the pre- and post-operative data were found in the mandibular angle, the distance between mandibular angle, length of ramus, ectropion angle of mandibular angle, triangle Go-Me-Go, the thickness, width and length of masseter. It indicates the skeleton structure is changed and some kind of atrophy happens in the masseter after operation. So we suggest partial resection of masseter should be unnecessary for mandibular angle osteotomy.

  7. Short cervical length dilemma.

    Science.gov (United States)

    Suhag, Anju; Berghella, Vincenzo

    2015-06-01

    Preterm birth (PTB) is a leading cause of neonatal morbidity and mortality. With research efforts, the rate of PTB decreased to 11.4% in 2013. Transvaginal ultrasound (TVU) cervical length (CL) screening predicts PTB. In asymptomatic singletons without prior spontaneous PTB (sPTB), TVU CL screening should be done. If the cervix is 20 mm or less, vaginal progesterone is indicated. In asymptomatic singletons with prior sPTB, serial CL screening is indicated. In multiple gestations, routine cervical screening is not indicated. In symptomatic women with preterm labor, TVU CL screening and fetal fibronectin testing is recommended. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. discouraged by queue length

    Directory of Open Access Journals (Sweden)

    P. R. Parthasarathy

    2001-01-01

    Full Text Available The transient solution is obtained analytically using continued fractions for a state-dependent birth-death queue in which potential customers are discouraged by the queue length. This queueing system is then compared with the well-known infinite server queueing system which has the same steady state solution as the model under consideration, whereas their transient solutions are different. A natural measure of speed of convergence of the mean number in the system to its stationarity is also computed.

  9. Primary length standard adjustment

    Science.gov (United States)

    Ševčík, Robert; Guttenová, Jana

    2007-04-01

    This paper deals with problems and techniques connected with primary length standard adjusting, which includes disassembling of the device and by use of the secondary laser with collimated beam and diffraction laws successively reassembling of the laser. In the reassembling process the device was enhanced with substituting the thermal grease cooling of cold finger by copper socket cooler. This improved external cooling system enables more effective cooling of molecular iodine in the cell, which allows better pressure stability of iodine vapor and easier readjustment of the system.

  10. A national facility for small angle neutron scattering

    International Nuclear Information System (INIS)

    Buyers, W.J.L.; Katsaras, J.; Mellors, W.; Potter, M.M.; Powell, B.M.; Rogge, R.B.; Root, J.H.; Tennant, D.C.; Tun, Z.

    1995-01-01

    A world-class small angle neutron scattering (SANS) facility is proposed for Canada. It will provide users from the fields of biology, chemistry, physics, materials science and engineering with a uniquely powerful tool for investigating microstructural properties whose length scales lie in the optical to atomic range. (author). 7 refs

  11. Generalization of the Euler Angles

    Science.gov (United States)

    Bauer, Frank H. (Technical Monitor); Shuster, Malcolm D.; Markley, F. Landis

    2002-01-01

    It is shown that the Euler angles can be generalized to axes other than members of an orthonormal triad. As first shown by Davenport, the three generalized Euler axes, hereafter: Davenport axes, must still satisfy the constraint that the first two and the last two axes be mutually perpendicular if these axes are to define a universal set of attitude parameters. Expressions are given which relate the generalized Euler angles, hereafter: Davenport angles, to the 3-1-3 Euler angles of an associated direction-cosine matrix. The computation of the Davenport angles from the attitude matrix and their kinematic equation are presented. The present work offers a more direct development of the Davenport angles than Davenport's original publication and offers additional results.

  12. Small Angle Scattering in Neutron Imaging—A Review

    Directory of Open Access Journals (Sweden)

    Markus Strobl

    2017-12-01

    Full Text Available Conventional neutron imaging utilizes the beam attenuation caused by scattering and absorption through the materials constituting an object in order to investigate its macroscopic inner structure. Small angle scattering has basically no impact on such images under the geometrical conditions applied. Nevertheless, in recent years different experimental methods have been developed in neutron imaging, which enable to not only generate contrast based on neutrons scattered to very small angles, but to map and quantify small angle scattering with the spatial resolution of neutron imaging. This enables neutron imaging to access length scales which are not directly resolved in real space and to investigate bulk structures and processes spanning multiple length scales from centimeters to tens of nanometers.

  13. Angle Performance on Optima XE

    International Nuclear Information System (INIS)

    David, Jonathan; Satoh, Shu

    2011-01-01

    Angle control on high energy implanters is important due to shrinking device dimensions, and sensitivity to channeling at high beam energies. On Optima XE, beam-to-wafer angles are controlled in both the horizontal and vertical directions. In the horizontal direction, the beam angle is measured through a series of narrow slits, and any angle adjustment is made by steering the beam with the corrector magnet. In the vertical direction, the beam angle is measured through a high aspect ratio mask, and any angle adjustment is made by slightly tilting the wafer platen during implant.Using a sensitive channeling condition, we were able to quantify the angle repeatability of Optima XE. By quantifying the sheet resistance sensitivity to both horizontal and vertical angle variation, the total angle variation was calculated as 0.04 deg. (1σ). Implants were run over a five week period, with all of the wafers selected from a single boule, in order to control for any crystal cut variation.

  14. Coherent Smith-Purcell radiation as a diagnostic for sub-picosecond electron bunch length

    International Nuclear Information System (INIS)

    Nguyen, D.C.

    1996-01-01

    We suggest a novel technique of measuring sub-picosecond electron bunch length base on coherent Smith-Purcell radiation (SPR) emitted when electrons pass close to the surface of a metal grating. With electron bunch lengths comparable to the grating period, we predict that coherent SPR will be emitted at large angles with respect to direction of beam propagation. As the bunch length shortens, the coherent SPR will be enhanced over the incoherent component that is normally observed at small angles. Furthermore, the angular distribution of the coherent SPR will be shifted toward smaller angles as the bunch length becomes much smaller than the grating period. By measuring the angular distribution of the coherent SPR, one can determine the bunch length of sub-picosecond electron pulses. This new technique is easy to implement and appears capable of measuring femtosecond electron bunch lengths

  15. Relationship between the Angle of Repose and Angle of Internal ...

    African Journals Online (AJOL)

    ghum and rice. The angles have a big influence on the design offlow and storage structures of ... the angles of internal friction for the same grains and same moisture contents. The data ob- tained were fed into SAS statistical software for step-wise regression analysis. A model of the ..... tion, Application and Validation of En-.

  16. Small angle neutron scattering

    Directory of Open Access Journals (Sweden)

    Cousin Fabrice

    2015-01-01

    Full Text Available Small Angle Neutron Scattering (SANS is a technique that enables to probe the 3-D structure of materials on a typical size range lying from ∼ 1 nm up to ∼ a few 100 nm, the obtained information being statistically averaged on a sample whose volume is ∼ 1 cm3. This very rich technique enables to make a full structural characterization of a given object of nanometric dimensions (radius of gyration, shape, volume or mass, fractal dimension, specific area… through the determination of the form factor as well as the determination of the way objects are organized within in a continuous media, and therefore to describe interactions between them, through the determination of the structure factor. The specific properties of neutrons (possibility of tuning the scattering intensity by using the isotopic substitution, sensitivity to magnetism, negligible absorption, low energy of the incident neutrons make it particularly interesting in the fields of soft matter, biophysics, magnetic materials and metallurgy. In particular, the contrast variation methods allow to extract some informations that cannot be obtained by any other experimental techniques. This course is divided in two parts. The first one is devoted to the description of the principle of SANS: basics (formalism, coherent scattering/incoherent scattering, notion of elementary scatterer, form factor analysis (I(q→0, Guinier regime, intermediate regime, Porod regime, polydisperse system, structure factor analysis (2nd Virial coefficient, integral equations, characterization of aggregates, and contrast variation methods (how to create contrast in an homogeneous system, matching in ternary systems, extrapolation to zero concentration, Zero Averaged Contrast. It is illustrated by some representative examples. The second one describes the experimental aspects of SANS to guide user in its future experiments: description of SANS spectrometer, resolution of the spectrometer, optimization of

  17. Ultra small angle neutron scattering from superconducting filament structures

    International Nuclear Information System (INIS)

    Amenitsch, H.

    1999-01-01

    With a perfect crystal camera, ultra small-angle scattering measurements were performed to investigate the internal diffusion process of tin inside a superconducting multi-filament wire caused by a temperature treatment. Commercially available Nb 3 Sn superconducting multi-filament wires were treated at 700 C with varying ageing times up to 144 h. A theoretical model taking into account the geometrical form, the size distribution, the interference term and the multiple scattering has been developed to understand and to describe the small angle diffraction pattern. Additionally, the diffusion of H and D into the filament wires was used to vary the scattering length density inside the wires. The results show a direct relationship between the different technological treatments and the characteristic small-angle scattering parameters, like Guinier radius and small-angle scattering probability. (orig.) [de

  18. Influence of intramuscular fiber orientation on the Achilles tendon curvature using three-dimensional finite element modeling of contracting skeletal muscle.

    Science.gov (United States)

    Kinugasa, Ryuta; Yamamura, Naoto; Sinha, Shantanu; Takagi, Shu

    2016-10-03

    Tendon curvature plays a key role in mechanical gain (amplifying the joint excursion relative to fiber length change) during joint motion, but the mechanism remains unresolved. A three-dimensional finite element (FE) model was used to investigate the influence of intramuscular fiber orientation upon the curvature pattern of the Achilles tendon during active muscular contraction. Two simulation models, with fiber pennation angles of θ = 25° and 47° were tested for the gastrocnemius and soleus muscles. A smaller pennation angle (25°) of the soleus muscle fibers was accompanied by a large change in curvature whereas a larger pennation angle (47°) of the soleus muscle was accompanied by small effects. These results suggest that the fiber pennation angle determines the curvature of the tendon, and the magnitude of the curvature varies along the length of the aponeurosis. Such FE modeling has the potential of determining changes in force output consequent to changes in intramuscular fiber orientation arising from resistance training or unloading, and provides mechanism for predicting the risk of Achilles tendon ruptures. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. A Study of Radiation Incidence Angle in Anteroposterior Cervical Vertebra Examination

    International Nuclear Information System (INIS)

    Jeung, Seung Woon; Lim, Cheong Hwan; Jung, Hong Ryang; Joo, Yeong Cheol; Park, Mi Ja; Han, Beon Hee

    2012-01-01

    In anteroposterior projection for cervical vertebra, it is general that the incidence angle of X-ray is 15 degrees to 20 degrees to head in order to prevent overlap of mandible and occipital bone and to observe array of cervical interbody and shapes of joints. However, the angle is appropriate for foreigners that was determined by foreign literature review long ago, and there have been few researches of incidence angle for Koreans' body type. The purpose of in this study are to identify the incidence angle appropriate for Koreans and to present methodology. In order to measure the incidence angle, 1,044 patients who visited S Hospital located in Seosan were selected and measured of average length of cervical vertebra, OID, axis angle, and FID. The incidence angle was calculated from the applied formula by measuring average values per age groups and sex (see Formula 1 and 2). The average length of cervical vertebra was 6cm: the length was increased from teenagers to twenties but was decreased since thirties. The difference between males and females was around 1cm (p<.01). The OID was almost the same regardless of age groups and sex. As for axis angle, the slope was increased in teenagers and twenties, but was decreased since thirties. The difference between males and females was around 2 degrees (p<.01). The FID measurements were almost the same regardless of age groups and sex, and when the incidence angle was measured from these values, the teenagers were 15.9 degrees, the twenties were 16.9 degrees, the thirties were 16.6 degrees, the forties were 16.2 degrees, the fifties were 15.9 degrees, and the sixties were 14.5 degrees, indicating that the angle was increased from teenagers to the twenties but decreased since the thirties. While the angles of males and females were measured to be the same in the teenagers, the angle was different between males and females by 2 degrees. When the incidence angle statistically analyzed with measurement of average length of

  20. A Study of Radiation Incidence Angle in Anteroposterior Cervical Vertebra Examination

    Energy Technology Data Exchange (ETDEWEB)

    Jeung, Seung Woon; Lim, Cheong Hwan; Jung, Hong Ryang; Joo, Yeong Cheol; Park, Mi Ja [Dept. of Radiological Science, Hanseo University, Seosan (Korea, Republic of); Han, Beon Hee [Dept. of Radiological Science, Seonam University, Namwon (Korea, Republic of)

    2012-06-15

    In anteroposterior projection for cervical vertebra, it is general that the incidence angle of X-ray is 15 degrees to 20 degrees to head in order to prevent overlap of mandible and occipital bone and to observe array of cervical interbody and shapes of joints. However, the angle is appropriate for foreigners that was determined by foreign literature review long ago, and there have been few researches of incidence angle for Koreans' body type. The purpose of in this study are to identify the incidence angle appropriate for Koreans and to present methodology. In order to measure the incidence angle, 1,044 patients who visited S Hospital located in Seosan were selected and measured of average length of cervical vertebra, OID, axis angle, and FID. The incidence angle was calculated from the applied formula by measuring average values per age groups and sex (see Formula 1 and 2). The average length of cervical vertebra was 6cm: the length was increased from teenagers to twenties but was decreased since thirties. The difference between males and females was around 1cm (p<.01). The OID was almost the same regardless of age groups and sex. As for axis angle, the slope was increased in teenagers and twenties, but was decreased since thirties. The difference between males and females was around 2 degrees (p<.01). The FID measurements were almost the same regardless of age groups and sex, and when the incidence angle was measured from these values, the teenagers were 15.9 degrees, the twenties were 16.9 degrees, the thirties were 16.6 degrees, the forties were 16.2 degrees, the fifties were 15.9 degrees, and the sixties were 14.5 degrees, indicating that the angle was increased from teenagers to the twenties but decreased since the thirties. While the angles of males and females were measured to be the same in the teenagers, the angle was different between males and females by 2 degrees. When the incidence angle statistically analyzed with measurement of average length

  1. Measurement of the angle gamma

    International Nuclear Information System (INIS)

    Aleksan, R.; Sphicas, P.; Massachusetts Inst. of Tech., Cambridge, MA

    1993-12-01

    The angle γ as defined in the Wolfenstein approximation is not completely out of reach of current or proposed dedicated B experiments. This work represents but a first step in the direction of extracting the third angle of the unitarity triangle by study the feasibility of using new decay modes in a hadronic machine. (A.B.). 11 refs., 1 fig., 7 tabs

  2. Nucleation of small angle boundaries

    CSIR Research Space (South Africa)

    Nabarro, FRN

    1996-12-01

    Full Text Available The internal stresses induced by the strain gradients in an array of lattice cells delineated by low-angle dislocation boundaries are partially relieved by the creation of new low-angle boundaries. This is shown to be a first-order transition...

  3. Correlation lengths of electrostatic turbulence

    International Nuclear Information System (INIS)

    Guiziou, L.; Garbet, X.

    1995-01-01

    This document deals with correlation length of electrostatic turbulence. First, the model of drift waves turbulence is presented. Then, the radial correlation length is determined analytically with toroidal coupling and non linear coupling. (TEC). 5 refs

  4. Topographical length scales of hierarchical superhydrophobic surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Dhillon, P.K. [Department of Physics, Indian Institute of Technology Ropar, Nangal Road, Rupnagar, Punjab 140001 (India); Brown, P.S.; Bain, C.D.; Badyal, J.P.S. [Department of Chemistry, Science Laboratories, Durham University, Durham DH1 3LE, England (United Kingdom); Sarkar, S., E-mail: sarkar@iitrpr.ac.in [Department of Physics, Indian Institute of Technology Ropar, Nangal Road, Rupnagar, Punjab 140001 (India)

    2014-10-30

    Highlights: • Hydrophobic CF{sub 4} plasma fluorinated polybutadiene surfaces has been characterised using AFM. • Micro, Nano, and Micro + Nano topographies generated by altering plasma power and duration. • Dynamic scaling theory and FFT analysis used to characterize these surfaces quantitatively. • Roughnesses are different for different length scales of the surfaces considered. • Highest local roughness obtained from scaling analysis for shorter length scales of about 500 nm explains the superhydrophobicity for the Micro + Nano surface. - Abstract: The morphology of hydrophobic CF{sub 4} plasma fluorinated polybutadiene surfaces has been characterised using atomic force microscopy (AFM). Judicious choice of the plasma power and exposure duration leads to formation of three different surface morphologies (Micro, Nano, and Micro + Nano). Scaling theory analysis shows that for all three surface topographies, there is an initial increase in roughness with length scale followed by a levelling-off to a saturation level. At length scales around 500 nm, it is found that the roughness is very similar for all three types of surfaces, and the saturation roughness value for the Micro + Nano morphology is found to be intermediate between those for the Micro and Nano surfaces. Fast Fourier Transform (FFT) analysis has shown that the Micro + Nano topography comprises a hierarchical superposition of Micro and Nano morphologies. Furthermore, the Micro + Nano surfaces display the highest local roughness (roughness exponent α = 0.42 for length scales shorter than ∼500 nm), which helps to explain their superhydrophobic behaviour (large water contact angle (>170°) and low hysteresis (<1°))

  5. Correlation lengths of electrostatic turbulence

    International Nuclear Information System (INIS)

    Guiziou, L.; Garbet, X.

    1995-01-01

    In this paper, the radial correlation length of an electrostatic drift wave turbulence is analytically determined in various regimes. The analysis relies on the calculation of a range of mode non linear interaction, which is an instantaneous correlation length. The link with the usual correlation length has not been investigated yet. (TEC). 5 refs

  6. The Effect of Glancing Angle Deposition Conditions on the Morphology of a Silver Nanohelix Array

    Directory of Open Access Journals (Sweden)

    Yi-Jun Jen

    2017-09-01

    Full Text Available Silver nanohelices were grown on smooth substrates using glancing angle deposition and substrate cooling. Various nanohelix arrays were deposited under different deposition conditions—different deposition rates, substrate spin rates, deposition angles, and substrate temperatures. The effect of deposition conditions on the morphology of each nanohelix array in terms of pitch angle, pitch length, wire diameter, and radius of curvature was investigated. The dependence of circular dichroism on the size of the nanohelix arrays was also measured and demonstrated.

  7. Small Angle X-ray Scattering: Going Beyond the Bragg Peaks -24 ...

    Indian Academy of Sciences (India)

    This article gives an introduction to the princi- ples of small angle scattering. Some applications of this technique are also briefly discussed. Introduction. Small angle X-ray scattering (SAXS) is a widely used technique to study large scale inhomogeneities in a med- ium, at length scales much larger than the wavelength.

  8. Oblique-Length Contraction Factor in the Special Theory of Relativity

    Directory of Open Access Journals (Sweden)

    Smarandache F.

    2013-01-01

    Full Text Available In this paper one generalizes the Lorentz Contraction Factor for the case when the lengths are moving at an oblique angle with respect to the motion direction. One shows that the angles of the moving relativistic objects are distorted.

  9. Observations at large zenith angles

    CERN Document Server

    Schroeder, F

    2000-01-01

    Cherenkov telescope observations at zenith angles >70 deg. are capable of providing large collection areas for high energy gamma-induced air showers. In order to provide a full Monte Carlo simulation of the large zenith angle observations the air shower simulation code CORSIKA was modified to treat particles in a curved geometry. First results of studies with the stand alone telescope HEGRA CT1 are presented.

  10. [Comparison between the tooth length measured by cone-beam CT and the tooth length measured with vernier caliper].

    Science.gov (United States)

    Yang, Yi-qiang; Mi, Zhen-lin; Ge, Zhen-lin

    2013-11-01

    To evaluate the accuracy of cone-bean CT (CBCT) on the measurement of the tooth length. One hundred and sixty single root premolars extracted for orthodontic purposes were selected. The tooth length was measured with vernier caliper. The premolars were divided into 10 groups randomly, 16 premolars in each group.In each group, the teeth were lined in molar area, premolar area, canine area and anterior tooth area in maxilla and mandible. Then CBCT was taken, and the tooth length was measured using the software supplied by the manufacturer in coronal and sagittal plane. Accuracy was compared between vernier caliper measurement and CBCT measurement. The tooth length measured by CBCT was smaller than that measured with the vernier caliper. Significant differences were found in six areas, except the maxillary and mandibular premolar areas. With the increase of mesial-distal inclination or buccolingual torque angle, the difference between tooth length measured by CBCT and that measured with vernier caliper increased. The correlation between buccolingual torque angle (∠X1) and the coronal view of CBCT radiology tooth length (Spearmen index was 7.00, P caliper.

  11. Apparent and microscopic dynamic contact angles in confined flows

    Science.gov (United States)

    Omori, Takeshi; Kajishima, Takeo

    2017-11-01

    An abundance of empirical correlations between a dynamic contact angle and a capillary number representing a translational velocity of a contact line have been provided for the last decades. The experimentally obtained dynamic contact angles are inevitably apparent contact angles but often undistinguished from microscopic contact angles formed right on the wall. As Bonn et al. ["Wetting and spreading," Rev. Mod. Phys. 81, 739-805 (2009)] pointed out, however, most of the experimental studies simply report values of angles recorded at some length scale which is quantitatively unknown. It is therefore hard to evaluate or judge the physical validity and the generality of the empirical correlations. The present study is an attempt to clear this clutter regarding the dynamic contact angle by measuring both the apparent and the microscopic dynamic contact angles from the identical data sets in a well-controlled manner, by means of numerical simulation. The numerical method was constructed so that it reproduced the fine details of the flow with a moving contact line predicted by molecular dynamics simulations [T. Qian, X. Wang, and P. Sheng, "Molecular hydrodynamics of the moving contact line in two-phase immiscible flows," Commun. Comput. Phys. 1, 1-52 (2006)]. We show that the microscopic contact angle as a function of the capillary number has the same form as Blake's molecular-kinetic model [T. Blake and J. Haynes, "Kinetics of liquid/liquid displacement," J. Colloid Interface Sci. 30, 421-423 (1969)], regardless of the way the flow is driven, the channel width, the mechanical properties of the receding fluid, and the value of the equilibrium contact angle under the conditions where the Reynolds and capillary numbers are small. We have also found that the apparent contact angle obtained by the arc-fitting of the interface behaves surprisingly universally as claimed in experimental studies in the literature [e.g., X. Li et al., "An experimental study on dynamic pore

  12. Anomalous and resonance small-angle scattering

    International Nuclear Information System (INIS)

    Epperson, J.E.; Thiyagarajan, P.

    1988-01-01

    Significant changes in the small-angle scattered intensity can be induced by making measurements with radiation close to an absorption edge of an appropriate atomic species contained in the sample. These changes can be related quantitatively to the real and imaginary anomalous-dispersion terms for the scattering factor (X-rays) or scattering length (neutrons). The physics inherent in these anomalous-dispersion terms is first discussed before consideration of how they enter the relevant scattering theory. Two major areas of anomalous-scattering research have emerged; macromolecules in solution and unmixing of metallic alloys. Research in each area is reviewed, illustrating both the feasibility and potential of these techniques. All the experimental results reported to date have been obtained with X-rays. However, it is pointed out that the formalism is the same for the analog experiment with neutrons, and a number of suitable isotopes exist which exhibit resonance in an accessible range of energy. Potential applications of resonance small-angle neutron scattering are discussed. (orig.)

  13. Anomalous and resonance small angle scattering

    International Nuclear Information System (INIS)

    Epperson, J.E.; Thiyagarajan, P.

    1987-11-01

    Significant changes in the small angle scattered intensity can be induced by making measurements with radiation close to an absorption edge of an appropriate atomic species contained in the sample. These changes can be related quantitatively to the real and imaginary anomalous dispersion terms for the scattering factor (x-rays) or scattering length (neutrons). The physics inherent in these anomalous dispersion terms is first discussed before considering how they enter the relevant scattering theory. Two major areas of anomalous scattering research have emerged; macromolecules in solution and unmixing of metallic alloys. Research in each area is reviewed, illustrating both the feasibility and potential of these techniques. All the experimental results reported to date have been obtained with x-rays. However, it is pointed out that the formalism is the same or the analogue experiment with neutrons, and a number of suitable isotopes exist which exhibit resonance in an accessible range of energy. Potential applications of resonance small-angle neutron scatterings are discussed. 8 figs

  14. Study of the Inception Length of Flow over Stepped Spillway Models ...

    African Journals Online (AJOL)

    The results showed that the inception (development) length increases as the unit discharge increases and it decreases with an increase in both stepped roughness height and chute angle. The ratio of the development length, in this study, to that of Bauer's was found to be 4:5. Finally, SMM-5 produced the least velocity of ...

  15. Effects of slant angle and illumination angle on MTF estimations

    CSIR Research Space (South Africa)

    Vhengani, LM

    2012-07-01

    Full Text Available angle d(?) was not constant. It was also noted that the iris of the imaging system was in most cases adjusted during initial setups of each measurements. After each measurement, the knife-edge target was replaced with the ISO 12233 MTF target (shown....085 0.09 0.095 K:\\Working Folder\\Project_On_orbit MTF\\edgetargets\\MTF_Lab_Measurements _20120302_Edge Slant Angle (degrees) Ny qu ist MT F (c yc le/p ixe l) Data Regression -18 -16 -14 -12 -10 -8 -6 -4 -2 0.05 0.055 0.06 0...

  16. Comparison of different passive knee extension torque-angle assessments

    International Nuclear Information System (INIS)

    Freitas, Sandro R; Vaz, João R; Bruno, Paula M; Valamatos, Maria J; Mil-Homens, Pedro

    2013-01-01

    Previous studies have used isokinetic dynamometry to assess joint torques and angles during passive extension of the knee, often without reporting upon methodological errors and reliability outcomes. In addition, the reliability of the techniques used to measure passive knee extension torque-angle and the extent to which reliability may be affected by the position of the subjects is also unclear. Therefore, we conducted an analysis of the intra- and inter-session reliability of two methods of assessing passive knee extension: (A) a 2D kinematic analysis coupled to a custom-made device that enabled the direct measurement of resistance to stretch and (B) an isokinetic dynamometer used in two testing positions (with the non-tested thigh either flexed at 45° or in the neutral position). The intra-class correlation coefficients (ICCs) of torque, the slope of the torque-angle curve, and the parameters of the mathematical model that were fit to the torque-angle data for the above conditions were measured in sixteen healthy male subjects (age: 21.4 ± 2.1 yr; BMI: 22.6 ± 3.3 kg m −2 ; tibial length: 37.4 ± 3.4 cm). The results found were: (1) methods A and B led to distinctly different torque-angle responses; (2) passive torque-angle relationship and stretch tolerance were influenced by the position of the non-tested thigh; and (3) ICCs obtained for torque were higher than for the slope and for the mathematical parameters that were fit to the torque-angle curve. In conclusion, the measurement method that is used and the positioning of subjects can influence the passive knee extension torque-angle outcome. (paper)

  17. 7 Length-weight relationship

    African Journals Online (AJOL)

    Administrator

    Length-weight measurements were taken from well-preserved fish specimens from which stomachs were extracted for the analysis of the food contents, using frequency of occurrence, numerical and gravimetric methods, as well as index of relative importance. The length-frequency analysis showed a size distribution with a ...

  18. Comparison of fiber length analyzers

    Science.gov (United States)

    Don Guay; Nancy Ross Sutherland; Walter Rantanen; Nicole Malandri; Aimee Stephens; Kathleen Mattingly; Matt Schneider

    2005-01-01

    In recent years, several fiber new fiber length analyzers have been developed and brought to market. The new instruments provide faster measurements and the capability of both laboratory and on-line analysis. Do the various fiber analyzers provide the same length, coarseness, width, and fines measurements for a given fiber sample? This paper provides a comparison of...

  19. Frequency scaling for angle gathers

    KAUST Repository

    Zuberi, M. A H

    2014-01-01

    Angle gathers provide an extra dimension to analyze the velocity after migration. Space-shift and time shift-imaging conditions are two methods used to obtain angle gathers, but both are reasonably expensive. By scaling the time-lag axis of the time-shifted images, the computational cost of the time shift imaging condition can be considerably reduced. In imaging and more so Full waveform inversion, frequencydomain Helmholtz solvers are used more often to solve for the wavefields than conventional time domain extrapolators. In such cases, we do not need to extend the image, instead we scale the frequency axis of the frequency domain image to obtain the angle gathers more efficiently. Application on synthetic data demonstrate such features.

  20. Smith Purcell Radiation Bunch-Length Measurement

    CERN Document Server

    Korbly, Stephen; Marsh, Roark A; Temkin, Richard J

    2005-01-01

    Measurements of Coherent Smith-Purcell Radiation (SPR) were performed at the 17 GHz high-gradient accelerator built by Haimson Research Corporation at the MIT Plasma Science and Fusion Center. SPR is a promising radiation source because the radiation intensity is enhanced by the number of grating periods. The radiation produced obeys the SP resonance condition correlating the radiation frequency at each observation angle, allowing SPR to be exploited as a bunch-length measurement. For a 15 MeV 150 mA 125 ns beam in short and long pulse modes, bunch-lengths of 0.6 ps and 1 ps were measured with this method, respectively, with an error of ± 0.1 ps. Frequency measurements were also performed using a double Heterodyne system. Heterodyne measurements revealed frequency-locking, which gave a power level enhancement of 1000 at integer multiples of the Accelerator RF frequency. Frequencies up to 514 GHz were measured with a bandwidth of 25 MHz.

  1. Temperature dependence of Brewster's angle.

    Science.gov (United States)

    Guo, Wei

    2018-01-01

    In this work, a dielectric at a finite temperature is modeled as an ensemble of identical atoms moving randomly around where they are trapped. Light reflection from the dielectric is then discussed in terms of atomic radiation. Specific calculation demonstrates that because of the atoms' thermal motion, Brewster's angle is, in principle, temperature-dependent, and the dependence is weak in the low-temperature limit. What is also found is that the Brewster's angle is nothing but a result of destructive superposition of electromagnetic radiation from the atoms.

  2. Angle independent velocity spectrum determination

    DEFF Research Database (Denmark)

    2014-01-01

    An ultrasound imaging system (100) includes a transducer array (102) that emits an ultrasound beam and produces at least one transverse pulse-echo field that oscillates in a direction transverse to the emitted ultrasound beam and that receive echoes produced in response thereto and a spectral vel...... velocity estimator (110) that determines a velocity spectrum for flowing structure, which flows at an angle of 90 degrees and flows at angles less than 90 degrees with respect to the emitted ultrasound beam, based on the received echoes....

  3. Interpretation of Endodontic File Length Adjustments Using Radiovisiography

    Science.gov (United States)

    1993-01-01

    radiographic views. I ENDODONTIC WORKING LENGTH History of Dental Radiography The x-ray was discovered in 1895 by Wilhelm Roentgen in WUrzburg, Germany...bisecting angle I I I 32 I technique is unreliable for making radiographs of diagnostic g value in endodontics . Much research has been done assessing the...conventional radiography but not at a statistically * significant level. Two reports by Shearer et al. 5 0 ,51 looked specifically at the endodontic

  4. Influence of body mass and lower limb length on knee flexion angle during walking in humans

    Czech Academy of Sciences Publication Activity Database

    Hora, M.; Sládek, Vladimír; Soumar, L.; Stráníková, K.; Michálek, T.

    2012-01-01

    Roč. 61, 3-4 (2012), s. 330-339 ISSN 0139-7893 R&D Projects: GA ČR GA206/09/0589 Institutional support: RVO:68081766 Keywords : size * posture * locomotion * biomechanics Subject RIV: EG - Zoology Impact factor: 0.494, year: 2012

  5. A Hitch Angle Measurement Device

    National Research Council Canada - National Science Library

    Von

    1998-01-01

    As part of a project to demonstrate that an unmanned ground vehicle (UGV) could remotely back up with a trailer, a simple proof-of-concept device was designed to measure the angle between a high-mobility multipurpose wheeled vehicle (HMMWV...

  6. Small-angle neutron-scattering experiment, (2)

    International Nuclear Information System (INIS)

    Niimura, Nobuo; Kaji, Harumi.

    1983-01-01

    Elementary explanation is given to the experiment on the small angle scattering using neutrons having long wave-length (3-12A), continued from the previous report. Two types of the apparatus for small angle neutron scattering experiment are described. The first is angle dispersion type, which uses the neutron beam from research reactors, and the second is wavelength dispersion type, which uses pulsed cold neutron sources. The principles of these experiments are explained. Especially the wavelength dispersion is described in detail. The apparatus in the booster facility at the Institute for High Energy Physics is shown as an example for the latter type. The two-dimensional position sensitive detector, which is essential for angle dispersion type, is also used for the wavelength dispersion type, and its data processing is also described. In the small angle neutron scattering experiment for the studies on the structure of living body substances, the techniques that should be taken into account in common are discussed; the proportion of D 2 O-H 2 O in solvent, the measurable range of Q, the size of specimens, the correction of incident neutron spectra, and the analysis of measured data. (Asami, T.)

  7. Characterization of porous materials by small-angle scattering

    International Nuclear Information System (INIS)

    Mazumder, S.; Sen, D.; Patra, A.K.

    2004-01-01

    Characterization of porous materials by small-angle scattering has been extensively pursued for several years now as the pores are often of mesoscopic size and compatible with the length scale accessible by the technique using both neutrons and X-rays as probing radiation. With the availability of ultra small-angle scattering instruments, one can investigate porous materials in the sub-micron length scale. Because of the increased accessible length scale vis-a-vis the multiple scattering effect, conventional data analysis procedures based on single scattering approximation quite often fail. The limitation of conventional data analysis procedures is also pronounced in the case of thick samples and long wavelength of the probing radiation. Effect of multiple scattering is manifested by broadening the scattering profile. Sample thickness for some technologically important materials is often significantly high, as the experimental samples have to replicate all its essential properties in the bulk material. Larger wavelength of the probing radiation is used in some cases to access large length scale and also to minimize the effect of double Bragg reflections. (author)

  8. Measurement of the angle gamma

    International Nuclear Information System (INIS)

    Aleksan, R.; Kayser, B.; Sphicas, P.

    1993-01-01

    The angle γ at least as defined in the Wolfenstein approximation is not completely out of reach of current or proposed dedicated B experiments. This conclusion certainly depends crucially on the assumed trigger and tagging efficiencies and also on the expected backgrounds. The work summarized here represents but a first step in the direction of extracting the third angle of the unitarity triangle. The theoretical developments during the workshop have resulted in a clearer understanding of the quantities studied. On the experimental side, new decay modes (i.e. in addition to the traditional ρK s decay) have resulted in expections for observing CP violation in B s decays which are not unreasonable. It is conceivable that a dedicated B experiment can probe a fundamental aspect of the Standard Model, the CKM matrix, in multiple ways. In the process, new physics can appear anywhere along the line

  9. Contact angles on stretched solids

    Science.gov (United States)

    Mensink, Liz; Snoeijer, Jacco

    2017-11-01

    The surface energy of solid interfaces plays a central role in wetting, as they dictate the liquid contact angle. Yet, it has been challenging to measure the solid surface energies independently, without making use of Young's law. Here we present Molecular Dynamics (MD) simulations by which we measure the surface properties for all interfaces, including the solids. We observe change in contact angles upon stretching the solid substrates, showing that the surface energy is actually strain dependent. This is clear evidence of the so-called Shuttleworth effect, making it necessary to distinguish surface energy from surface tension. We discuss how this effect gives rise to a new class of elasto-capillary phenomena. ERC Consolidator Grant No. 616918.

  10. LHC Report: playing with angles

    CERN Multimedia

    Mike Lamont for the LHC team

    2016-01-01

    Ready (after a machine development period), steady (running), go (for a special run)!   The crossing angles are an essential feature of the machine set-up. They have to be big enough to reduce the long-range beam-beam effect. The LHC has recently enjoyed a period of steady running and managed to set a new record for “Maximum Stable Luminosity Delivered in 7 days” of 3.29 fb-1 between 29 August and 4 September. The number of bunches per beam remains pegged at 2220 because of the limitations imposed by the SPS beam dump. The bunch population is also somewhat reduced due to outgassing near one of the injection kickers at point 8. Both limitations will be addressed during the year-end technical stop, opening the way for increased performance in 2017. On 10 and 11 September, a two day machine development (MD) period took place. The MD programme included a look at the possibility of reducing the crossing angle at the high-luminosity interaction points. The crossing angles are an ess...

  11. Light Scattering at Various Angles

    Science.gov (United States)

    Latimer, Paul; Pyle, B. E.

    1972-01-01

    The Mie theory of scattering is used to provide new information on how changes in particle volume, with no change in dry weight, should influence light scattering for various scattering angles and particle sizes. Many biological cells (e.g., algal cells, erythrocytes) and large subcellular structures (e.g., chloroplasts, mitochondria) in suspension undergo this type of reversible volume change, a change which is related to changes in the rates of cellular processes. A previous study examined the effects of such volume changes on total scattering. In this paper scattering at 10° is found to follow total scattering closely, but scattering at 45°, 90°, 135°, and 170° behaves differently. Small volume changes can cause very large observable changes in large angle scattering if the sample particles are uniform in size; however, the natural particle size heterogeneity of most samples would mask this effect. For heterogeneous samples of most particle size ranges, particle shrink-age is found to increase large angle scattering. PMID:4556610

  12. Angle comparison using an autocollimator

    Science.gov (United States)

    Geckeler, Ralf D.; Just, Andreas; Vasilev, Valentin; Prieto, Emilio; Dvorácek, František; Zelenika, Slobodan; Przybylska, Joanna; Duta, Alexandru; Victorov, Ilya; Pisani, Marco; Saraiva, Fernanda; Salgado, Jose-Antonio; Gao, Sitian; Anusorn, Tonmueanwai; Leng Tan, Siew; Cox, Peter; Watanabe, Tsukasa; Lewis, Andrew; Chaudhary, K. P.; Thalmann, Ruedi; Banreti, Edit; Nurul, Alfiyati; Fira, Roman; Yandayan, Tanfer; Chekirda, Konstantin; Bergmans, Rob; Lassila, Antti

    2018-01-01

    Autocollimators are versatile optical devices for the contactless measurement of the tilt angles of reflecting surfaces. An international key comparison (KC) on autocollimator calibration, EURAMET.L-K3.2009, was initiated by the European Association of National Metrology Institutes (EURAMET) to provide information on the capabilities in this field. The Physikalisch-Technische Bundesanstalt (PTB) acted as the pilot laboratory, with a total of 25 international participants from EURAMET and from the Asia Pacific Metrology Programme (APMP) providing measurements. This KC was the first one to utilise a high-resolution electronic autocollimator as a standard. In contrast to KCs in angle metrology which usually involve the full plane angle, it focused on relatively small angular ranges (+/-10 arcsec and +/-1000 arcsec) and step sizes (10 arcsec and 0.1 arcsec, respectively). This document represents the approved final report on the results of the KC. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. CEBAF Upgrade Bunch Length Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, Mahmoud [Old Dominion Univ., Norfolk, VA (United States)

    2016-05-01

    Many accelerators use short electron bunches and measuring the bunch length is important for efficient operations. CEBAF needs a suitable bunch length because bunches that are too long will result in beam interruption to the halls due to excessive energy spread and beam loss. In this work, bunch length is measured by invasive and non-invasive techniques at different beam energies. Two new measurement techniques have been commissioned; a harmonic cavity showed good results compared to expectations from simulation, and a real time interferometer is commissioned and first checkouts were performed. Three other techniques were used for measurements and comparison purposes without modifying the old procedures. Two of them can be used when the beam is not compressed longitudinally while the other one, the synchrotron light monitor, can be used with compressed or uncompressed beam.

  14. Continuously variable focal length lens

    Science.gov (United States)

    Adams, Bernhard W; Chollet, Matthieu C

    2013-12-17

    A material preferably in crystal form having a low atomic number such as beryllium (Z=4) provides for the focusing of x-rays in a continuously variable manner. The material is provided with plural spaced curvilinear, optically matched slots and/or recesses through which an x-ray beam is directed. The focal length of the material may be decreased or increased by increasing or decreasing, respectively, the number of slots (or recesses) through which the x-ray beam is directed, while fine tuning of the focal length is accomplished by rotation of the material so as to change the path length of the x-ray beam through the aligned cylindrical slows. X-ray analysis of a fixed point in a solid material may be performed by scanning the energy of the x-ray beam while rotating the material to maintain the beam's focal point at a fixed point in the specimen undergoing analysis.

  15. Plateau iris in Japanese patients with primary angle closure and primary angle closure glaucoma.

    Science.gov (United States)

    Mizoguchi, Takanori; Ozaki, Mineo; Wakiyama, Harumi; Ogino, Nobuchika

    2015-01-01

    To determine the prevalence of plateau iris in Japanese patients with primary angle closure (PAC) and primary angle closure glaucoma (PACG) and analyze the biometric parameters in patients with plateau iris using ultrasound biomicroscopy (UBM). In this cross-sectional observational study, subjects aged >50 years with PAC and PACG who had previously undergone a patent laser peripheral iridotomy underwent UBM in one eye. UBM images were qualitatively analyzed using standardized criteria. Plateau iris in a quadrant was defined by anteriorly directed ciliary body, absent ciliary sulcus, steep iris root from its point of insertion followed by a downward angulation, flat iris plane, and irido-angle contact. At least two quadrants had to fulfill these UBM criteria for an eye to be classified as having plateau iris. A-scan biometry was used to measure anterior segment parameters. Ninety-one subjects with PAC (58 subjects) or PACG (33 subjects) and 68 normal controls were recruited. The mean (standard deviation) ages of PAC and PACG patients and normal controls were 73.5 (6.2) and 72.6 (7.3), respectively. Based on UBM criteria, plateau iris was found in 16 eyes (17.6%) of 91 eyes. In these 16 eyes, quadrant-wise analysis showed ten eyes (62.5%) had plateau iris in two quadrants; four eyes (25%) had plateau iris in three quadrants; and two eyes (12.5%) had plateau iris in four quadrants. Anterior chamber depth, lens thickness, axial length, lens position, and relative lens position were not statistically significant between the group having plateau iris and that not having plateau iris, respectively. Approximately 20% of Japanese subjects with PAC and PACG with a patent laser peripheral iridotomy were found to have plateau iris on UBM. No morphological difference was noted in the anterior segment of the eye between those with or without plateau iris.

  16. Overview of bunch length measurements

    International Nuclear Information System (INIS)

    Lumpkin, A. H.

    1999-01-01

    An overview of particle and photon beam bunch length measurements is presented in the context of free-electron laser (FEL) challenges. Particle-beam peak current is a critical factor in obtaining adequate FEL gain for both oscillators and self-amplified spontaneous emission (SASE) devices. Since measurement of charge is a standard measurement, the bunch length becomes the key issue for ultrashort bunches. Both time-domain and frequency-domain techniques are presented in the context of using electromagnetic radiation over eight orders of magnitude in wavelength. In addition, the measurement of microbunching in a micropulse is addressed

  17. Kondo length in bosonic lattices

    Science.gov (United States)

    Giuliano, Domenico; Sodano, Pasquale; Trombettoni, Andrea

    2017-09-01

    Motivated by the fact that the low-energy properties of the Kondo model can be effectively simulated in spin chains, we study the realization of the effect with bond impurities in ultracold bosonic lattices at half filling. After presenting a discussion of the effective theory and of the mapping of the bosonic chain onto a lattice spin Hamiltonian, we provide estimates for the Kondo length as a function of the parameters of the bosonic model. We point out that the Kondo length can be extracted from the integrated real-space correlation functions, which are experimentally accessible quantities in experiments with cold atoms.

  18. Small angle neutron scattering study of disordered and crystalline iron nanoparticle assemblies

    International Nuclear Information System (INIS)

    Farrell, D.F.; Ijiri, Y.; Kelly, C.V.; Borchers, J.A.; Rhyne, J.J.; Ding, Y.; Majetich, S.A.

    2006-01-01

    Monodisperse surfactant-coated iron nanoparticles are used to form both disordered nanoparticle assemblies and ordered face-centered cubic nanoparticle crystals. The structural order is probed by small angle X-ray scattering, and the magnetic scattering is studied using small angle neutron scattering. The magnetic scattering corresponding to different length scales is interpreted in terms of collective correlations among the particles within the assemblies

  19. Cyclic codes of length 2

    Indian Academy of Sciences (India)

    Springer Verlag Heidelberg #4 2048 1996 Dec 15 10:16:45

    [X]/〈X2m. − 1〉 are given. Cyclic codes of length 2m over the finite field Fq, of odd characteristic, are defined in terms of their generator polynomials. The exact minimum distance and the dimension of the codes are obtained. Keywords.

  20. Diet, nutrition and telomere length.

    Science.gov (United States)

    Paul, Ligi

    2011-10-01

    The ends of human chromosomes are protected by DNA-protein complexes termed telomeres, which prevent the chromosomes from fusing with each other and from being recognized as a double-strand break by DNA repair proteins. Due to the incomplete replication of linear chromosomes by DNA polymerase, telomeric DNA shortens with repeated cell divisions until the telomeres reach a critical length, at which point the cells enter senescence. Telomere length is an indicator of biological aging, and dysfunction of telomeres is linked to age-related pathologies like cardiovascular disease, Parkinson disease, Alzheimer disease and cancer. Telomere length has been shown to be positively associated with nutritional status in human and animal studies. Various nutrients influence telomere length potentially through mechanisms that reflect their role in cellular functions including inflammation, oxidative stress, DNA integrity, DNA methylation and activity of telomerase, the enzyme that adds the telomeric repeats to the ends of the newly synthesized DNA. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. Fractional baud-length coding

    Directory of Open Access Journals (Sweden)

    J. Vierinen

    2011-06-01

    Full Text Available We present a novel approach for modulating radar transmissions in order to improve target range and Doppler estimation accuracy. This is achieved by using non-uniform baud lengths. With this method it is possible to increase sub-baud range-resolution of phase coded radar measurements while maintaining a narrow transmission bandwidth. We first derive target backscatter amplitude estimation error covariance matrix for arbitrary targets when estimating backscatter in amplitude domain. We define target optimality and discuss different search strategies that can be used to find well performing transmission envelopes. We give several simulated examples of the method showing that fractional baud-length coding results in smaller estimation errors than conventional uniform baud length transmission codes when estimating the target backscatter amplitude at sub-baud range resolution. We also demonstrate the method in practice by analyzing the range resolved power of a low-altitude meteor trail echo that was measured using a fractional baud-length experiment with the EISCAT UHF system.

  2. Femur length and biparietal diameter

    African Journals Online (AJOL)

    2014-12-02

    Dec 2, 2014 ... Shipp TD, Bromley B, Mascola M, Benacerraf B. Variation in fetal femur length with respect to maternal race. J Ultrasound Med 2001;20:141‑4. 25. Deter RL, Harrist RB, Birnholz JC, Hadlock FP. Quantitative Obstetrical. Ultrasonography. New York: Wiley; 1986. 26. Yeh MN, Bracero L, Reilly KB, Murtha L, ...

  3. Small angle scattering and polymers

    Energy Technology Data Exchange (ETDEWEB)

    Cotton, J.P. [Laboratoire Leon Brillouin (LLB) - Centre d`Etudes de Saclay, 91 - Gif-sur-Yvette (France)

    1996-12-31

    The determination of polymer structure is a problem of interest for both statistical physics and industrial applications. The average polymer structure is defined. Then, it is shown why small angle scattering, associated with isotopic substitution, is very well suited to the measurement of the chain conformation. The corresponding example is the old, but pedagogic, measurement of the chain form factor in the polymer melt. The powerful contrast variation method is illustrated by a recent determination of the concentration profile of a polymer interface. (author) 12 figs., 48 refs.

  4. Determination Method of Bridge Rotation Angle Response Using MEMS IMU.

    Science.gov (United States)

    Sekiya, Hidehiko; Kinomoto, Takeshi; Miki, Chitoshi

    2016-11-09

    To implement steel bridge maintenance, especially that related to fatigue damage, it is important to monitor bridge deformations under traffic conditions. Bridges deform and rotate differently under traffic load conditions because their structures differ in terms of length and flexibility. Such monitoring enables the identification of the cause of stress concentrations that cause fatigue damage and the proposal of appropriate countermeasures. However, although bridge deformation monitoring requires observations of bridge angle response as well as the bridge displacement response, measuring the rotation angle response of a bridge subject to traffic loads is difficult. Theoretically, the rotation angle response can be calculated by integrating the angular velocity, but for field measurements of actual in-service bridges, estimating the necessary boundary conditions would be difficult due to traffic-induced vibration. To solve the problem, this paper proposes a method for determining the rotation angle response of an in-service bridge from its angular velocity, as measured by a inertial measurement unit (IMU). To verify our proposed method, field measurements were conducted using nine micro-electrical mechanical systems (MEMS) IMUs and two contact displacement gauges. The results showed that our proposed method provided high accuracy when compared to the reference responses calculated by the contact displacement gauges.

  5. Plateau iris in Japanese patients with primary angle closure and primary angle closure glaucoma

    Directory of Open Access Journals (Sweden)

    Mizoguchi T

    2015-06-01

    Full Text Available Takanori Mizoguchi,1 Mineo Ozaki,2,3 Harumi Wakiyama,1,4 Nobuchika Ogino1,51Mizoguchi Eye Clinic, Nagasaki, Japan; 2Ozaki Eye Clinic Miyazaki, Japan; 3Department of Ophthalmology, Faculty of Medicine, University of Miyazaki, Miyazaki, Japan; 4The Japanese Red Cross Nagasaki Genbaku Hospital, Nagasaki, Japan; 5Nishigaki Eye Clinic, Nagoya, JapanPurpose: To determine the prevalence of plateau iris in Japanese patients with primary angle closure (PAC and primary angle closure glaucoma (PACG and analyze the biometric parameters in patients with plateau iris using ultrasound biomicroscopy (UBM.Methods: In this cross-sectional observational study, subjects aged >50 years with PAC and PACG who had previously undergone a patent laser peripheral iridotomy underwent UBM in one eye. UBM images were qualitatively analyzed using standardized criteria. Plateau iris in a quadrant was defined by anteriorly directed ciliary body, absent ciliary sulcus, steep iris root from its point of insertion followed by a downward angulation, flat iris plane, and irido-angle contact. At least two quadrants had to fulfill these UBM criteria for an eye to be classified as having plateau iris. A-scan biometry was used to measure anterior segment parameters.Results: Ninety-one subjects with PAC (58 subjects or PACG (33 subjects and 68 normal controls were recruited. The mean (standard deviation ages of PAC and PACG patients and normal controls were 73.5 (6.2 and 72.6 (7.3, respectively. Based on UBM criteria, plateau iris was found in 16 eyes (17.6% of 91 eyes. In these 16 eyes, quadrant-wise analysis showed ten eyes (62.5% had plateau iris in two quadrants; four eyes (25% had plateau iris in three quadrants; and two eyes (12.5% had plateau iris in four quadrants. Anterior chamber depth, lens thickness, axial length, lens position, and relative lens position were not statistically significant between the group having plateau iris and that not having plateau iris

  6. Contact Angle Measurement in Lattice Boltzmann Method

    OpenAIRE

    Wen, Binghai; Huang, Bingfang; Qin, Zhangrong; Wang, Chunlei; Zhang, Chaoying

    2017-01-01

    Contact angle is an essential characteristic in wetting, capillarity and moving contact line; however, although contact angle phenomena are effectively simulated, an accurate and real-time measurement for contact angle has not been well studied in computational fluid dynamics, especially in dynamic environments. Here, we design a geometry-based mesoscopic scheme to onthesport measure the contact angle in the lattice Boltzmann method. The computational results without gravity effect are in exc...

  7. Three-dimensional architecture of the whole human soleus muscle in vivo

    Science.gov (United States)

    Finni, Taija; D’Souza, Arkiev; Eguchi, Junya; Clarke, Elizabeth C.; Herbert, Robert D.

    2018-01-01

    Background Most data on the architecture of the human soleus muscle have been obtained from cadaveric dissection or two-dimensional ultrasound imaging. We present the first comprehensive, quantitative study on the three-dimensional anatomy of the human soleus muscle in vivo using diffusion tensor imaging (DTI) techniques. Methods We report three-dimensional fascicle lengths, pennation angles, fascicle curvatures, physiological cross-sectional areas and volumes in four compartments of the soleus at ankle joint angles of 69 ± 12° (plantarflexion, short muscle length; average ± SD across subjects) and 108 ± 7° (dorsiflexion, long muscle length) of six healthy young adults. Microdissection and three-dimensional digitisation on two cadaveric muscles corroborated the compartmentalised structure of the soleus, and confirmed the validity of DTI-based muscle fascicle reconstructions. Results The posterior compartments of the soleus comprised 80 ± 5% of the total muscle volume (356 ± 58 cm3). At the short muscle length, the average fascicle length, pennation angle and curvature was 37 ± 8 mm, 31 ± 3° and 17 ± 4 /m, respectively. We did not find differences in fascicle lengths between compartments. However, pennation angles were on average 12° larger (p < 0.01) in the posterior compartments than in the anterior compartments. For every centimetre that the muscle-tendon unit lengthened, fascicle lengths increased by 3.7 ± 0.8 mm, pennation angles decreased by −3.2 ± 0.9° and curvatures decreased by −2.7 ± 0.8 /m. Fascicles in the posterior compartments rotated almost twice as much as in the anterior compartments during passive lengthening. Discussion The homogeneity in fascicle lengths and inhomogeneity in pennation angles of the soleus may indicate a functionally different role for the anterior and posterior compartments. The data and techniques presented here demonstrate how DTI can be used to obtain detailed, quantitative measurements of the

  8. 30 CFR 56.19037 - Fleet angles.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fleet angles. 56.19037 Section 56.19037 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND... Sheaves § 56.19037 Fleet angles. Fleet angles on hoists installed after November 15, 1979, shall not be...

  9. 30 CFR 57.19037 - Fleet angles.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fleet angles. 57.19037 Section 57.19037 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND... Sheaves § 57.19037 Fleet angles. Fleet angles on hoists installed after November 15, 1979, shall not be...

  10. Lateral angle and cranial base sexual dimorphism

    DEFF Research Database (Denmark)

    Duquesnel Mana, Mathilde; Adalian, Pascal; Lynnerup, Niels

    2016-01-01

    , to examine sexual dimorphism in the relationship between the lateral angle and cranial base shape. The lateral angle method was tested using a forensic sample of 102 CT scans of the head with known sex. We measured the angle using two methods: measurements directly on the CT slide, the method usually applied...

  11. Small-angle scattering, topography and radiography

    International Nuclear Information System (INIS)

    Schelten, J.

    1978-01-01

    A table is given showing scattering and imaging methods for X-rays and neutrons, followed, by a discussion of such topics as 1. Radiography 2. Topography 3. Small-angle scattering 3.1. The differential cross section 3.2. Comparison of X-ray and neutron small-angle scattering 3.3. Examples of small-angle scattering. (orig.) [de

  12. Modelling small-angle scattering data from complex protein-lipid systems

    DEFF Research Database (Denmark)

    Kynde, Søren Andreas Røssell

    as carriers of membrane proteins. Together they form monodisperse soluble aggregates of about 10 nm in size. Chapter 2 introduces the method of small-angle scattering. Small-angle X-ray and neutron scattering are well suited for studying particles in solution on length scales from 1 to 100 nm. This makes...... describes a protein system that has successfully been measured with small-angle scattering methods and subsequently analysed using the hybrid approach. Paper I governs the transmembrane protein bacteriorhodopsin embedded into a phospholipid nanodisc. The modelling is based on a crystal structure...

  13. Phase-angle jump during voltage dips in wind power installations

    Energy Technology Data Exchange (ETDEWEB)

    Gomez-Lazaro, E.; Canas, M.; Pujante, A.J. [Universidad de Castilla-La Mancha, Albacete (Spain). Renewable Energy Research Inst. and Dept. of Electrical, Electronic and Control Engineering; Fuentes, J.A.; Molina-Garcia, A. [Universidad Politecnica de Cartagena (Spain). Dept. of Electrical Engineering

    2008-07-01

    A voltage dip is a disturbance in the power system that consists in a sudden reduction of voltage level and a recovery in a short period of time, the magnitude and angle of the voltage phasors can be affected by this disturbance. The variation between the pre-fault voltage phasor angle and dip voltage phasor angle is called phase-angle jump. In this paper, it is carried out a study of the characteristics of real voltage dips. The study highlights the phase-angle jumps that appear on voltage dips, analyzing the influence of the voltage dip type, depth or length. Voltage dips have been acquired with power quality analyzers with a 10 MHz sample rate in a Spanish wind farm for 18 months. (orig.)

  14. Length of a Hanging Cable

    Directory of Open Access Journals (Sweden)

    Eric Costello

    2011-01-01

    Full Text Available The shape of a cable hanging under its own weight and uniform horizontal tension between two power poles is a catenary. The catenary is a curve which has an equation defined by a hyperbolic cosine function and a scaling factor. The scaling factor for power cables hanging under their own weight is equal to the horizontal tension on the cable divided by the weight of the cable. Both of these values are unknown for this problem. Newton's method was used to approximate the scaling factor and the arc length function to determine the length of the cable. A script was written using the Python programming language in order to quickly perform several iterations of Newton's method to get a good approximation for the scaling factor.

  15. Keeping disease at arm's length

    DEFF Research Database (Denmark)

    Lassen, Aske Juul

    2015-01-01

    and physical activities at the activity centre. In this way, keeping disease at arm’s length is analysed as an ambiguous health strategy. The article shows the importance of looking into how active ageing is practised, as active ageing seems to work well in the everyday life of the older people by not giving......Many older people live with a range of chronic diseases. However, these diseases do not necessarily impede an active lifestyle. In this article the author analyses the relation between the active ageing discourse and the way older people at two Danish activity centres handle disease. How does...... active ageing change everyday life with chronic disease, and how do older people combine an active life with a range of chronic diseases? The participants in the study use activities to keep their diseases at arm’s length, and this distancing of disease at the same time enables them to engage in social...

  16. Widening of the femoral proximal diaphysis--metaphysis angle in fetuses with achondroplasia.

    Science.gov (United States)

    Khalil, A; Morales-Roselló, J; Morlando, M; Bhide, A; Papageorghiou, A; Thilaganathan, B

    2014-07-01

    It has recently been reported that fetuses with achondroplasia have a wider than expected femoral proximal diaphysis-metaphysis angle (femoral angle). The aim of this case-control study was to investigate this finding. Cases with confirmed achondroplasia (n = 6), small-for-gestational-age fetuses (n = 70) and a group of normal fetuses (n = 377) were included in this study. The ultrasound image of the femur was examined by two independent experienced observers blinded to the diagnosis, who measured the femoral angle. These values were converted into multiples of the expected median (MoM), after adjustment for gestational age and femur length. Prevalence of various prenatal ultrasound signs of achondroplasia was determined in affected fetuses. Intra- and interobserver agreement of measurement of femoral angle was assessed using 95% limits of agreement and kappa statistics. The femoral angle can be measured accurately by ultrasound, and increases with both increasing gestational age and increasing femur length. The femoral angle-MoM was significantly higher in fetuses with achondroplasia than in the control group (1.36 vs 1.00 MoM, P achondroplasia (83.3%), which was the most consistent finding other than shortening of the long bones. The femoral angle is wider in fetuses with achondroplasia. This new ultrasound sign appears promising as an additional discriminatory marker when clinicians are faced with a case of short long bones in the third trimester. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.

  17. Finding the optimal lengths for three branches at a junction.

    Science.gov (United States)

    Woldenberg, M J; Horsfield, K

    1983-09-21

    This paper presents an exact analytical solution to the problem of locating the junction point between three branches so that the sum of the total costs of the branches is minimized. When the cost per unit length of each branch is known the angles between each pair of branches can be deduced following reasoning first introduced to biology by Murray. Assuming the outer ends of each branch are fixed, the location of the junction and the length of each branch are then deduced using plane geometry and trigonometry. The model has applications in determining the optimal cost of a branch or branches at a junction. Comparing the optimal to the actual cost of a junction is a new way to compare cost models for goodness of fit to actual junction geometry. It is an unambiguous measure and is superior to comparing observed and optimal angles between each daughter and the parent branch. We present data for 199 junctions in the pulmonary arteries of two human lungs. For the branches at each junction we calculated the best fitting value of x from the relationship that flow alpha (radius)x. We found that the value of x determined whether a junction was best fitted by a surface, volume, drag or power minimization model. While economy of explanation casts doubt that four models operate simultaneously, we found that optimality may still operate, since the angle to the major daughter is less than the angle to the minor daughter. Perhaps optimality combined with a space filling branching pattern governs the branching geometry of the pulmonary artery.

  18. The Small angle TIle Calorimeter project in DELPHI

    International Nuclear Information System (INIS)

    Alvsvaag, S.J.; Maeland, O.A.; Klovning, A.

    1995-01-01

    The new Small Angle TIle Calorimeter (STIC) covers the forward regions in DELPHI. The main motivation for its construction was to achieve a systematic error of 0.1% on the luminosity determination. This detector consists of a ''shashlik'' type calorimeter, equipped with two planes of silicon pad detectors placed respectively after 4 and 7.4 radiation lengths. A veto counter, composed of two scintillator planes, covers the front of the calorimeter to allow e-γ separation and to provide a neutral energy trigger.The physics motivations for this project, results from extensive testbeam measurements and the performance during the 1994 LEP run are reported here. (orig.)

  19. GALAXI: Gallium anode low-angle x-ray instrument

    Directory of Open Access Journals (Sweden)

    Emmanuel Kentzinger

    2016-03-01

    Full Text Available The high brilliance laboratory small angle X-ray scattering instrument GALAXI, which is operated by JCNS, Forschungszentrum Jülich, permits the investigation of chemical correlations in bulk materials or of structures deposited on a surface at nanometre and mesoscopic length scales. The instrument is capable to perform GISAXS experiments in reflection at grazing incidence as well as SAXS experiments in transmission geometry. The X-ray flux on sample is comparable or higher than the one obtained at a comparable beamline at a second generation synchrotron radiation source.

  20. The Q-angle and sport

    DEFF Research Database (Denmark)

    Hahn, Thomas; Foldspang, Anders

    1997-01-01

    Quadriceps muscle contraction tends to straighten the Q angle. We expected that sports comprising a high amount of quadriceps training could be associated with low Q angles. The aim of the present study was to estimate the Q angle in athletes and to investigate its potential associations with par......Quadriceps muscle contraction tends to straighten the Q angle. We expected that sports comprising a high amount of quadriceps training could be associated with low Q angles. The aim of the present study was to estimate the Q angle in athletes and to investigate its potential associations...... with participation in sport. Three hundred and thirty-nine athletes had their Q angle measured. The mean of right-side Q angles was higher than left side, and the mean Q angle was higher in women than in men. The Q angle was positively associated with years of jogging, and negatively with years of soccer, swimming...... and sports participation at all. It is concluded that the use of Q angle measurements is questionable....

  1. Individualized optimal release angles in discus throwing.

    Science.gov (United States)

    Leigh, Steve; Liu, Hui; Hubbard, Mont; Yu, Bing

    2010-02-10

    The purpose of this study was to determine individualized optimal release angles for elite discus throwers. Three-dimensional coordinate data were obtained for at least 10 competitive trials for each subject. Regression relationships between release speed and release angle, and between aerodynamic distance and release angle were determined for each subject. These relationships were linear with subject-specific characteristics. The subject-specific relationships between release speed and release angle may be due to subjects' technical and physical characteristics. The subject-specific relationships between aerodynamic distance and release angle may be due to interactions between the release angle, the angle of attack, and the aerodynamic distance. Optimal release angles were estimated for each subject using the regression relationships and equations of projectile motion. The estimated optimal release angle was different for different subjects, and ranged from 35 degrees to 44 degrees . The results of this study demonstrate that the optimal release angle for discus throwing is thrower-specific. The release angles used by elite discus throwers in competition are not necessarily optimal for all discus throwers, or even themselves. The results of this study provide significant information for understanding the biomechanics of discus throwing techniques. Copyright 2009 Elsevier Ltd. All rights reserved.

  2. Spirality: A Noval Way to Measure Spiral Arm Pitch Angle

    Science.gov (United States)

    Shields, Douglas W.; Boe, Benjamin; Henderson, Casey L.; Hartley, Matthew; Davis, Benjamin L.; Pour Imani, Hamed; Kennefick, Daniel; Kennefick, Julia D.

    2015-01-01

    We present the MATLAB code Spirality, a novel method for measuring spiral arm pitch angles by fitting galaxy images to spiral templates of known pitch. For a given pitch angle template, the mean pixel value is found along each of typically 1000 spiral axes. The fitting function, which shows a local maximum at the best-fit pitch angle, is the variance of these means. Error bars are found by varying the inner radius of the measurement annulus and finding the standard deviation of the best-fit pitches. Computation time is typically on the order of 2 minutes per galaxy, assuming at least 8 GB of working memory. We tested the code using 128 synthetic spiral images of known pitch. These spirals varied in the number of spiral arms, pitch angle, degree of logarithmicity, radius, SNR, inclination angle, bar length, and bulge radius. A correct result is defined as a result that matches the true pitch within the error bars, with error bars no greater than ±7°. For the non-logarithmic spiral sample, the correct answer is similarly defined, with the mean pitch as function of radius in place of the true pitch. For all synthetic spirals, correct results were obtained so long as SNR > 0.25, the bar length was no more than 60% of the spiral's diameter (when the bar was included in the measurement), the input center of the spiral was no more than 6% of the spiral radius away from the true center, and the inclination angle was no more than 30°. The synthetic spirals were not deprojected prior to measurement. The code produced the correct result for all barred spirals when the measurement annulus was placed outside the bar. Additionally, we compared the code's results against 2DFFT results for 203 visually selected spiral galaxies in GOODS North and South. Among the entire sample, Spirality's error bars overlapped 2DFFT's error bars 64% of the time. For those galaxies in which Source code is available by email request from the primary author.

  3. Wafer scale oblique angle plasma etching

    Science.gov (United States)

    Burckel, David Bruce; Jarecki, Jr., Robert L.; Finnegan, Patrick Sean

    2017-05-23

    Wafer scale oblique angle etching of a semiconductor substrate is performed in a conventional plasma etch chamber by using a fixture that supports a multiple number of separate Faraday cages. Each cage is formed to include an angled grid surface and is positioned such that it will be positioned over a separate one of the die locations on the wafer surface when the fixture is placed over the wafer. The presence of the Faraday cages influences the local electric field surrounding each wafer die, re-shaping the local field to be disposed in alignment with the angled grid surface. The re-shaped plasma causes the reactive ions to follow a linear trajectory through the plasma sheath and angled grid surface, ultimately impinging the wafer surface at an angle. The selected geometry of the Faraday cage angled grid surface thus determines the angle at with the reactive ions will impinge the wafer.

  4. Observation of nuclear dechanneling length reduction for high energy protons in a short bent crystal

    Directory of Open Access Journals (Sweden)

    W. Scandale

    2015-04-01

    Full Text Available Deflection of 400 GeV/c protons by a short bent silicon crystal was studied at the CERN SPS. It was shown that the dechanneling probability increases while the dechanneling length decreases with an increase of incident angles of particles relative to the crystal planes. The observation of the dechanneling length reduction provides evidence of the particle population increase at the top levels of transverse energies in the potential well of the planar channels.

  5. Small-angle neutron scattering instrument at MINT

    International Nuclear Information System (INIS)

    Mohd Ali Sufi; Yusof Abdullah; Razali Kassim; Hamid; Shahidan Radiman; Mohammad Deraman; Abdul Ghaffar Ramli

    1996-01-01

    The Small Angle Neutron Scattering (SANS) Instrument has been developed at Malaysian Institute for Nuclear Technology Research (MINT) for studying structural properties of materials on the length scale 1 nm to 100 nm. This is the length scale which is relevant for many topics within soft condensed matter, like polymers, colloids, biological macromolecules, etc. The SANS is a complementary technique to X-ray and electron scattering. However, while these later techniques give information on structures near surface, SANS concerns the structure of the bulk. Samples studied by SANS technique are typically bulk materials of the sizes mm's to cm's, or materials dissolved in a liquid. This paper described the general characteristics of SANS instrument as well as the experimental formulation in neutron scattering. The preliminary results obtained by this instrument are shown

  6. Small-angle scattering study of Aspergillus awamori glycoprotein glucoamylase

    International Nuclear Information System (INIS)

    Schmidt, A. E.; Shvetsov, A. V.; Kuklin, A. I.; Lebedev, D. V.; Surzhik, M. A.; Sergeev, V. R.; Isaev-Ivanov, V. V.

    2016-01-01

    Glucoamylase from fungus Aspergillus awamori is glycoside hydrolase that catalyzes the hydrolysis of α-1,4- and α-1,6-glucosidic bonds in glucose polymers and oligomers. This glycoprotein consists of a catalytic domain and a starch-binding domain connected by an O-glycosylated polypeptide chain. The conformation of the linker, the relative arrangement of the domains, and the structure of the full-length enzyme are unknown. The structure of the recombinant glucoamylase GA1 was studied by molecular modelling and small-angle neutron scattering (SANS) methods. The experimental SANS data provide evidence that glucoamylase exists as a monomer in solution and contains a glycoside component, which makes a substantial contribution to the scattering. The model of full-length glucoamylase, which was calculated without taking into account the effect of glycosylation, is consistent with the experimental data and has a radius of gyration of 33.4 ± 0.6 Å

  7. Small-angle scattering study of Aspergillus awamori glycoprotein glucoamylase

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, A. E., E-mail: schmidt@omrb.pnpi.spb.ru; Shvetsov, A. V. [National Research Center “Kurchatov Institute”, Konstantinov Petersburg Nuclear Physics Institute (Russian Federation); Kuklin, A. I. [Joint Institute for Nuclear Research (Russian Federation); Lebedev, D. V.; Surzhik, M. A.; Sergeev, V. R.; Isaev-Ivanov, V. V. [National Research Center “Kurchatov Institute”, Konstantinov Petersburg Nuclear Physics Institute (Russian Federation)

    2016-01-15

    Glucoamylase from fungus Aspergillus awamori is glycoside hydrolase that catalyzes the hydrolysis of α-1,4- and α-1,6-glucosidic bonds in glucose polymers and oligomers. This glycoprotein consists of a catalytic domain and a starch-binding domain connected by an O-glycosylated polypeptide chain. The conformation of the linker, the relative arrangement of the domains, and the structure of the full-length enzyme are unknown. The structure of the recombinant glucoamylase GA1 was studied by molecular modelling and small-angle neutron scattering (SANS) methods. The experimental SANS data provide evidence that glucoamylase exists as a monomer in solution and contains a glycoside component, which makes a substantial contribution to the scattering. The model of full-length glucoamylase, which was calculated without taking into account the effect of glycosylation, is consistent with the experimental data and has a radius of gyration of 33.4 ± 0.6 Å.

  8. Small-angle scattering study of Aspergillus awamori glycoprotein glucoamylase

    Science.gov (United States)

    Schmidt, A. E.; Shvetsov, A. V.; Kuklin, A. I.; Lebedev, D. V.; Surzhik, M. A.; Sergeev, V. R.; Isaev-Ivanov, V. V.

    2016-01-01

    Glucoamylase from fungus Aspergillus awamori is glycoside hydrolase that catalyzes the hydrolysis of α-1,4- and α-1,6-glucosidic bonds in glucose polymers and oligomers. This glycoprotein consists of a catalytic domain and a starch-binding domain connected by an O-glycosylated polypeptide chain. The conformation of the linker, the relative arrangement of the domains, and the structure of the full-length enzyme are unknown. The structure of the recombinant glucoamylase GA1 was studied by molecular modelling and small-angle neutron scattering (SANS) methods. The experimental SANS data provide evidence that glucoamylase exists as a monomer in solution and contains a glycoside component, which makes a substantial contribution to the scattering. The model of full-length glucoamylase, which was calculated without taking into account the effect of glycosylation, is consistent with the experimental data and has a radius of gyration of 33.4 ± 0.6 Å.

  9. Topological investigation of nuclear graphite using small angle scattering

    Science.gov (United States)

    Rai, Durgesh K.; Khaykovich, Boris; Campbell, Anne A.; Ilvasky, Jan; Katoh, Yutai; Snead, Lance L.

    Nuclear power reactors require high performance materials that withstand high temperatures and neutron damage over long period of times. Graphite is widely used for high temperature fission reactor applications. It has a complex multiphase microstructure, which is affected by neutron irradiation. The irradiation-induced microstructures result in significant thermophysical property changes, affecting service lifetimes. It is important to understand these life-limiting phenomena at many different length scales. We present the results from small angle scattering (SAS) studies on graphite samples, which vary in doses and irradiation temperatures. The neutron and synchrotron SAS measurement data indicates that the graphite morphology consists of surface fractal structures. The samples were found to be uniform across several decades of length scale, while exhibiting different surface fractal dimensions, for different irradiation doses and temperature conditions. The surface fractal dimension changes at HFIR at ORNL, DOE User Facility; APS at ANL, DOE User Facility; Office of Nuclear Energy NSUF.

  10. Effect of injection angle, density ratio, and viscosity on droplet formation in a microfluidic T-junction

    Directory of Open Access Journals (Sweden)

    Mohammad Yaghoub Abdollahzadeh Jamalabadi

    2017-07-01

    Full Text Available The T-junction microchannel device makes available a sharp edge to form micro-droplets from bio-material solutions. This article investigates the effects of injection angle, flow rate ratio, density ratio, viscosity ratio, contact angle, and slip length in the process of formation of uniform droplets in microfluidic T-junctions. The governing equations were solved by the commercial software. The results show that contact angle, slip length, and injection angles near the perpendicular and parallel conditions have an increasing effect on the diameter of generated droplets, while flow rate, density and viscosity ratios, and other injection angles had a decreasing effect on the diameter. Keywords: Microfluidics, Droplet formation, Flow rate ratio, Density ratio

  11. Analysis of artificial silicon microstructures by ultra-small-angle and spin-echo small-angle neutron scattering

    Energy Technology Data Exchange (ETDEWEB)

    Trinker, M. [Atominstitut, Vienna University of Technology, A-1020 Vienna (Austria)], E-mail: mtrinker@ati.ac.at; Jericha, E. [Atominstitut, Vienna University of Technology, A-1020 Vienna (Austria); Bouwman, W.G. [Faculty of Applied Sciences, Delft University of Technology, 2629 JB Delft (Netherlands); Loidl, R. [Atominstitut, Vienna University of Technology, A-1020 Vienna (Austria); Institute Laue-Langevin, F-38042 Grenoble (France); Rauch, H. [Atominstitut, Vienna University of Technology, A-1020 Vienna (Austria)

    2007-09-11

    Ultra-Small-Angle Neutron Scattering (USANS) is currently becoming an effective technique for the analysis of structures in the micrometer range. The new Spin-Echo SANS (SESANS) method measures a signal in real space. In both cases microfabricated silicon gratings provide unique test procedures for the related devices and interpretations of the experimental data. A series of one-dimensional gratings was fabricated using a highly anisotropic ion etching technique (RIE) and measured at the USANS instrument S18 at ILL, Grenoble. Grating parameters derived from the experimental data are in agreement with the nominal values. Scattering length density correlation functions calculated from the USANS data are compared to SESANS correlation functions measured at the Delft University of Technology, demonstrating the reciprocity of the two scattering methods. Reconstruction techniques for one-dimensional scattering length density distributions are applied to the USANS data. The results are in good agreement with SEM micrographs of the samples.

  12. Knee Moment-Angle Characteristics and Semitendinosus Muscle Morphology in Children with Spastic Paresis Selected for Medial Hamstring Lengthening.

    Directory of Open Access Journals (Sweden)

    Helga Haberfehlner

    Full Text Available To increase knee range of motion and improve gait in children with spastic paresis (SP, the semitendinosus muscle (ST amongst other hamstring muscles is frequently lengthened by surgery, but with variable success. Little is known about how the pre-surgical mechanical and morphological characteristics of ST muscle differ between children with SP and typically developing children (TD. The aims of this study were to assess (1 how knee moment-angle characteristics and ST morphology in children with SP selected for medial hamstring lengthening differ from TD children, as well as (2 how knee moment-angle characteristics and ST morphology are related. In nine SP and nine TD children, passive knee moment-angle characteristics and morphology of ST (i.e. fascicle length, muscle belly length, tendon length, physiological cross-sectional area, and volume were assessed by hand-held dynamometry and freehand 3D ultrasound, respectively. At net knee flexion moments above 0.5 Nm, more flexed knee angles were found for SP compared to TD children. The measured knee angle range between 0 and 4 Nm was 30% smaller in children with SP. Muscle volume, physiological cross-sectional area, and fascicle length normalized to femur length were smaller in SP compared to TD children (62%, 48%, and 18%, respectively. Sixty percent of the variation in knee angles at 4 Nm net knee moment was explained by ST fascicle length. Altered knee moment-angle characteristics indicate an increased ST stiffness in SP children. Morphological observations indicate that in SP children planned for medial hamstring lengthening, the longitudinal and cross-sectional growth of ST muscle fibers is reduced. The reduced fascicle length can partly explain the increased ST stiffness and, hence, a more flexed knee joint in these SP children.

  13. Knee Moment-Angle Characteristics and Semitendinosus Muscle Morphology in Children with Spastic Paresis Selected for Medial Hamstring Lengthening.

    Science.gov (United States)

    Haberfehlner, Helga; Jaspers, Richard T; Rutz, Erich; Becher, Jules G; Harlaar, Jaap; van der Sluijs, Johannes A; Witbreuk, Melinda M; Romkes, Jacqueline; Freslier, Marie; Brunner, Reinald; Maas, Huub; Buizer, Annemieke I

    2016-01-01

    To increase knee range of motion and improve gait in children with spastic paresis (SP), the semitendinosus muscle (ST) amongst other hamstring muscles is frequently lengthened by surgery, but with variable success. Little is known about how the pre-surgical mechanical and morphological characteristics of ST muscle differ between children with SP and typically developing children (TD). The aims of this study were to assess (1) how knee moment-angle characteristics and ST morphology in children with SP selected for medial hamstring lengthening differ from TD children, as well as (2) how knee moment-angle characteristics and ST morphology are related. In nine SP and nine TD children, passive knee moment-angle characteristics and morphology of ST (i.e. fascicle length, muscle belly length, tendon length, physiological cross-sectional area, and volume) were assessed by hand-held dynamometry and freehand 3D ultrasound, respectively. At net knee flexion moments above 0.5 Nm, more flexed knee angles were found for SP compared to TD children. The measured knee angle range between 0 and 4 Nm was 30% smaller in children with SP. Muscle volume, physiological cross-sectional area, and fascicle length normalized to femur length were smaller in SP compared to TD children (62%, 48%, and 18%, respectively). Sixty percent of the variation in knee angles at 4 Nm net knee moment was explained by ST fascicle length. Altered knee moment-angle characteristics indicate an increased ST stiffness in SP children. Morphological observations indicate that in SP children planned for medial hamstring lengthening, the longitudinal and cross-sectional growth of ST muscle fibers is reduced. The reduced fascicle length can partly explain the increased ST stiffness and, hence, a more flexed knee joint in these SP children.

  14. Structural evolution of photocrosslinked silk fibroin and silk fibroin-based hybrid hydrogels: A small angle and ultra-small angle scattering investigation.

    Science.gov (United States)

    Whittaker, Jasmin L; Balu, Rajkamal; Knott, Robert; de Campo, Liliana; Mata, Jitendra P; Rehm, Christine; Hill, Anita J; Dutta, Naba K; Roy Choudhury, Namita

    2018-03-12

    Regenerated Bombyx mori silk fibroin (RSF) is a widely recognized protein for biomedical applications; however, its hierarchical gel structure is poorly understood. In this paper, the hierarchical structure of photocrosslinked RSF and RSF-based hybrid hydrogel systems: (i) RSF/Rec1-resilin and (ii) RSF/poly(N-vinylcaprolactam (PVCL) is reported for the first time using small-angle scattering (SAS) techniques. The structure of RSF in dilute to concentrated solution to fabricated hydrogels were characterized using small angle X-ray scattering (SAXS), small angle neutron scattering (SANS) and ultra-small angle neutron scattering (USANS) techniques. The RSF hydrogel exhibited three distinctive structural characteristics: (i) a Porod region in the length scale of 2 to 3nm due to hydrophobic domains (containing β-sheets) which exhibits sharp interfaces with the amorphous matrix of the hydrogel and the solvent, (ii) a Guinier region in the length scale of 4 to 20nm due to hydrophilic domains (containing turns and random coil), and (iii) a Porod-like region in the length scale of few micrometers due to water pores/channels exhibiting fractal-like characteristics. Addition of Rec1-resilin or PVCL to RSF and subsequent crosslinking systematically increased the nanoscale size of hydrophobic and hydrophilic domains, whereas decreased the homogeneity of pore size distribution in the microscale. The presented results have implications on the fundamental understanding of the structure-property relationship of RSF-based hydrogels. Copyright © 2018. Published by Elsevier B.V.

  15. Measurement of contact angles of aqueous solutions on some rock forming minerals

    Science.gov (United States)

    Takakura, M.; Katsura, M.; Nakashima, S.

    2007-12-01

    Wetting properties of fluids on earth's materials are controlling fluid flows and dynamics of the geological systems. Although the wetting behavior of industrial materials have been widely examined often by contact angle measurements, contact angles of rock-forming materials have not been commonly measured. Therefore, we have been measuring contact angles of some representative rock-forming minerals. The surfaces of solid samples were polished successively by emery papers then by grinding powders (alumina: up to \\sharp3000: grain size about 5 micrometers). Water droplet from a micro-syringe needle are placed on solid surfaces by moving up the sample stage. Images of water drops on the solid surfaces are captured from the horizontal direction with a CCD camera. Contact angles can be determined from the height and the length of the images by assuming them to be parts of circles. Over 60 measurements of contact angles of pure water on (101) and (011) faces plates cut from a natural quartz single crystal were repeated. The average contact angles of pure water on (101) and (011) faces of quartz were 48 ± 5 degrees and 52 ± 3 degrees, respectively. Contact angles of pure water on a natural calcite single crystal was also measured in the same way to be 37 ± 8 degrees. Contact angles of various aqueous solutions such as NaCl and NaHCO3 on these minerals will also be measured in order to evaluate wetting properties of natural rock-water systems.

  16. The neutron small-angle camera D11 at the high-flux reactor, Grenoble

    International Nuclear Information System (INIS)

    Ibel, K.

    1976-01-01

    The neutron small-angle scattering system at the high-flux reactor in Grenoble consists of three major parts: the supply of cold neutrons via bent neutron guides; the small-angle camera D11; and the data handling facilities. The camera D11 has an overall length of 80 m. The effective length of the camera is variable. The full length of the collimator before the fixed sample position can be reduced by movable neutron guides; the second flight path of 40 m full length contains detector sites in various positions. Thus a large range of momentum transfers can be used with the same relative resolution. Scattering angles between 5 x 10 -4 and 0.5 rad and neutron wavelengths from 0.2 to 2.0 nm are available. A large-area position-sensitive detector is used which allows simultaneous recording of intensities scattered at different angles; it is a multiwire proportional chamber. 3808 elements of 1 cm 2 are arranged in a two-dimensional matrix. (Auth.)

  17. Angle closure glaucoma secondary to psychotropic medications

    Directory of Open Access Journals (Sweden)

    John Ross Rocke

    2017-07-01

    Full Text Available Background Psychotropic medications are commonly associated anticholinergic side-effects. In susceptible patients, this can result in angle closure induced permanent loss of vision Aims To review the mechanism of angle closure and which psychotropics are most likely to precipitate this complication. Methods Literature review surrounding the mechanism of angle closure and pharmacology of various psychotropics Results Mydriasis, forward-displacement of the lens-iris diaphragm and ciliary body swelling are the mechanisms by which angle closure occurs. Anticholinergic side effects of psychotropic medications are most implicated in causing this. Conclusion Screening patients for risk factors of angle closure and either having them formally assessed or choosing psychotropics with minimal anticholinergic effects may avoid inducing angle closure.

  18. Effect of Corrugation Angle on Heat Transfer Studies of Viscous Fluids in Corrugated Plate Heat Exchangers

    Directory of Open Access Journals (Sweden)

    B Sreedhara Rao

    2015-04-01

    Full Text Available In the present investigation heat transfer studies are conducted in corrugated plate heat exchangers (PHEs having three different corrugation angles of 300, 400 and 500. The plate heat exchangers have a length of 30 cm and a width of 10 cm with a spacing of 5 mm. Water and 20% glycerol solution are taken as test fluids and hot fluid is considered as heating medium. The wall temperatures are measured along the length of exchanger at seven different locations by means of thermocouples. The inlet and outlet temperatures of test fluid and hot fluid are measured by means of four more thermocouples. The experiments are conducted at a flowrate ranging from 0.5 lpm to 6 lpm with the test fluid. Film heat transfer coefficient and Nusselt number are determined from the experimental data. These values are compared with different corrugation angles. The effects of corrugation angles on heat transfer rates are discussed.

  19. Reflection of X-rays from a rough surface at extremely small grazing angles.

    Science.gov (United States)

    Wen, Mingwu; Kozhevnikov, Igor V; Wang, Zhanshan

    2015-09-21

    Peculiarities of X-ray diffraction from a rough surface at an extremely small grazing angle of an incident beam are theoretically studied. The interrelation of four diffraction channels (coherent reflectance, coherent transmittance, diffuse scattering in vacuum, and scattering into the matter depth) is analyzed for different limiting cases (large and small correlation length of roughness and large and extremely small grazing angle of incident radiation). Both the Debye-Waller and the Nevot-Croce factors are demonstrated to describe improperly the features of X-ray diffraction at extremely small grazing angles. More appropriate simple analytic expressions for the specular reflectivity and total integrated scattering in vacuum are obtained instead. Transformation of one limiting diffraction regime into another one with variation in the correlation length of roughness is discussed.

  20. Influence of inflow angle on flexible flap aerodynamic performance

    International Nuclear Information System (INIS)

    Zhao, H Y; Ye, Z; Li, Z M; Li, C

    2013-01-01

    Large scale wind turbines have larger blade lengths and weights, which creates new challenges for blade design. This paper selects NREL S809 airfoil, and uses the parameterized technology to realize the flexible trailing edge deformation, researches the dynamic aerodynamic characteristics in the process of continuous flexible deformation, analyses the influence of inflow angle on flexible flap aerodynamic performance, in order to further realize the flexible wind turbine blade design and provides some references for the active control scheme. The results show that compared with the original airfoil, proper trailing edge deformation can improve the lift coefficient, reduce the drag coefficient, and thereby more efficiently realize flow field active control. With inflow angle increases, dynamic lift-drag coefficient hysteresis loop shape deviation occurs, even turns into different shapes. Appropriate swing angle can improve the flap lift coefficient, but may cause early separation of flow. To improve the overall performance of wind turbine blades, different angular control should be used at different cross sections, in order to achieve the best performance

  1. Direct angle resolved photoemission spectroscopy and ...

    Indian Academy of Sciences (India)

    Keywords. Condensed matter physics; high-c superconductivity; electronic properties; photoemission spectroscopy; angle resolved photoemission spectroscopy; cuprates; films; strain; pulsed laser deposition.

  2. The qualitative criterion of transient angle stability

    DEFF Research Database (Denmark)

    Lyu, R.; Xue, Y.; Xue, F.

    2015-01-01

    In almost all the literatures, the qualitative assessment of transient angle stability extracts the angle information of generators based on the swing curve. As the angle (or angle difference) of concern and the threshold value rely strongly on the engineering experience, the validity and robust...... of these criterions are weak. Based on the stability mechanism from the extended equal area criterion (EEAC) theory and combining with abundant simulations of real system, this paper analyzes the criterions in most literatures and finds that the results could be too conservative or too optimistic. It is concluded...

  3. Is ankle contracture after stroke due to abnormal intermuscular force transmission?

    Science.gov (United States)

    Diong, Joanna; Herbert, Robert D

    2015-02-01

    Contracture after stroke could be due to abnormal mechanical interactions between muscles. This study examined if ankle plantarflexor muscle contracture after stroke is due to abnormal force transmission between the gastrocnemius and soleus muscles. Muscle fascicle lengths were measured from ultrasound images of soleus muscles in five subjects with stroke and ankle contracture and six able-bodied subjects. Changes in soleus fascicle length or pennation during passive knee extension at fixed ankle angle were assumed to indicate intermuscular force transmission. Changes in soleus fascicle length or pennation were adjusted for changes in ankle motion. Subjects with stroke had significant ankle contracture. After adjustment for ankle motion, 9 of 11 subjects demonstrated small changes in soleus fascicle length with knee extension, suggestive of intermuscular force transmission. However, the small changes in fascicle length may have been artifacts caused by movement of the ultrasound transducers. There were no systematic differences in change in fascicle length (median between-group difference adjusting for ankle motion = -0.01, 95% CI -0.26-0.08 mm/degree of knee extension) or pennation (-0.05, 95% CI -0.15-0.07 degree/ degree of knee extension). This suggests ankle contractures after stroke were not due to abnormal (systematically increased or decreased) intermuscular force transmission between the gastrocnemius and soleus.

  4. The "lotus effect" explained: two reasons why two length scales of topography are important.

    Science.gov (United States)

    Gao, Lichao; McCarthy, Thomas J

    2006-03-28

    Surfaces containing 4 x 8 x 40 microm staggered rhombus posts were hydrophobized using two methods. One, using a dimethyldichlorosilane reaction in the vapor phase, introduces a smooth modified layer, and the other, a solution reaction using methyltrichlorosilane, imparts a second (nanoscopic) length scale of topography. The smooth modified surface exhibits contact angles of thetaA/thetaR = 176 degrees /156 degrees . Arguments are made that the pinning of the receding contact line by the post tops (with thetaA/thetaR = 104 degrees /103 degrees ) is responsible for the hysteresis. The second level of topography raises the contact angles of the post tops and the macroscopic sample to theta(A)/theta(R) = >176 degrees />176 degrees and eliminates hysteresis. The increase in Laplace pressure due to the increase in the advancing contact angle of the post tops is a second reason that two length scales of topography are important.

  5. Bilateral differences in muscle fascicle architecture are not related to the preferred leg in jumping athletes.

    Science.gov (United States)

    Aeles, Jeroen; Lenchant, Sietske; Vanlommel, Liesbeth; Vanwanseele, Benedicte

    2017-07-01

    In many sports, athletes have a preferred leg for sport-specific tasks, such as jumping, which leads to strength differences between both legs, yet the underlying changes in force-generating mechanical properties of the muscle remain unknown. The purpose of this study was to investigate whether the muscle architecture of the medial gastrocnemius (MG) is different between both legs in well-trained jumping athletes and untrained individuals. In addition, we investigated the effect of two ankle joint positions on ultrasound muscle architecture measurements. Muscle architecture of both legs was measured in 16 athletes and 11 untrained individuals at two ankle joint angles: one with the ankle joint in a tendon slack length (TSL) angle and one in a 90° angle. Fascicle lengths and pennation angles at TSL were not different between the preferred and non-preferred legs in either group. The comparison between groups showed no difference in fascicle length, but greater pennation angles were found in the athletes (21.7° ± 0.5°) compared to the untrained individuals (19.8° ± 0.6°). Analyses of the muscle architecture at a 90° angle yielded different results, mainly in the comparison between groups. These results provide only partial support for the notion of training-induced changes in muscle architecture as only differences in pennation angles were found between athletes and untrained individuals. Furthermore, our results provide support to the recommendation to take into account the tension-length relationship and to measure muscle architecture at individually determined tendon slack joint angles.

  6. Anterior segment changes after pharmacologic mydriasis using Pentacam and optical coherence tomography in angle closure suspects

    Directory of Open Access Journals (Sweden)

    Jing-Min Guo

    2015-10-01

    Full Text Available AIM:To compare the dynamic changes of anterior segment parameters especially iris morphology induced by pharmacologic mydriasis between angle closure suspects and normal controls.METHODS:The study group comprised 19 eyes of 19 angle closure suspects and 19 eyes of 19 age- and sex-matched normal open-angle eyes. Pentacam and optical coherence tomography measurements before and 30min after instillation of compound tropicamide eye drop were performed and compared. Biometric evaluations of iris tomography and anterior chamber angle were estimated by a customized image-processing software.RESULTS:Baseline axial length, iris cross sectional area and volume did not differ significantly between angle closure suspects and normal controls. Angle closure suspects had smaller pupil size, narrower anterior segment dimension and axial length, thinner iris with greater curve in comparison with normal controls. Pharmacologic mydriasis led to significant increments in iris thickness at 750 μm, anterior chamber depth and volume, whereas significant decrements in iris curve, cross sectional area and volume in both groups. Angle opening distance at 500 μm was increased significantly in normal controls (from 0.465±0.115 mm to 0.539±0.167 mm, P=0.009, but not in angle closure suspects (from 0.125±0.100 mm to 0.145±0.131 mm, P=0.326. Iris volume change per millimeter of pupil dilation (△IV/△PD decreased significantly less in angle closure suspects than normal controls (-2.47±1.33 mm2 vs -3.63±1.58 mm2, P=0.019. Linear regression analysis showed that the change of angle opening distance at 500 μm was associated most with the change of central anterior chamber depth (β=0.841, P=0.002 and △IV/△PD (β=0.028, P=0.002, followed by gender (β=0.062, P=0.032.CONCLUSION:Smaller iris volume decrement per millimeter of pupil dilation is related significantly with the less anterior angle opening in angle closure suspects after pharmacologic mydriasis. Dynamic

  7. A more informative approach for characterization of polymer monolithic phases: small angle neutron scattering/ultrasmall angle neutron scattering.

    Science.gov (United States)

    Ford, Kathleen M; Konzman, Brian G; Rubinson, Judith F

    2011-12-15

    Neutron scattering techniques have been used frequently to characterize geological specimens and to determine the structures of glasses and of polymers as solutions, suspensions, or melts. Little work has been reported on their application in determining polymers' structural properties relevant to separations. Here, we present a comparison of characterization results from nitrogen porosimetry and from combined small angle neutron scattering (SANS) and ultrasmall angle neutron scattering (USANS) experiments. We show that SANS is extremely sensitive to the pore characteristics. Both approaches can provide information about porosity and pore characteristics, but the neutron scattering techniques provide additional information in the form of the surface characteristics of the pores and their length scales. Fits of the scattering data show that cylindrical pores are present with diameters down to 0.6 μm and that, for length scales down to approxmately 20 Å, the material shows self-similar (fractal) slopes of -3.4 to -3.6. Comparison of these characteristics with other examples from the scattering literature indicate that further investigation of their meaning for chromatographic media is required.

  8. Molecular basis of chromatic adaptation in pennate diatom Phaeodactylum tricornutum

    Czech Academy of Sciences Publication Activity Database

    Herbstová, Miroslava; Bína, David; Koník, P.; Gardian, Zdenko; Vácha, František; Litvín, Radek

    2015-01-01

    Roč. 1847, 6-7 (2015), s. 534-543 ISSN 0005-2728 R&D Projects: GA ČR GBP501/12/G055 Institutional support: RVO:60077344 Keywords : Chromatic adaptation * Diatom * Heterokonta * Light harvesting antenna Subject RIV: CE - Biochemistry Impact factor: 4.864, year: 2015

  9. Using a grating analyser for SEMSANS investigations in the very small angle range

    International Nuclear Information System (INIS)

    Strobl, M.; Wieder, F.; Duif, C.P.; Hilger, A.; Kardjilov, N.; Manke, I.; Bouwman, W.G.

    2012-01-01

    Spin-echo modulation small-angle neutron scattering (SEMSANS) is based on the detection of spatial beam modulation, which is induced by triangular spin echo precession regions and subsequent spin analyses. In order to detect such signal and exploit it for small angle scattering investigations neutron detection with sub-millimeter spatial resolution is required. Here an approach is reported where instead of a position sensitive detector an absorption grating is used to analyze the beam modulation stepwise. The spin-echo length scan in this case is performed by varying the sample-to-detector distance. The real space correlation functions of reference sample structures in the range 10 2 nm, i.e. giving rise to small-angle scattering in the very small-angle range, are recorded and analyzed successfully.

  10. Contact angles on a soft solid: from Young's law to Neumann's law.

    Science.gov (United States)

    Marchand, Antonin; Das, Siddhartha; Snoeijer, Jacco H; Andreotti, Bruno

    2012-12-07

    The contact angle that a liquid drop makes on a soft substrate does not obey the classical Young's relation, since the solid is deformed elastically by the action of the capillary forces. The finite elasticity of the solid also renders the contact angles differently from those predicted by Neumann's law, which applies when the drop is floating on another liquid. Here, we derive an elastocapillary model for contact angles on a soft solid by coupling a mean-field model for the molecular interactions to elasticity. We demonstrate that the limit of a vanishing elastic modulus yields Neumann's law or a variation thereof, depending on the force transmission in the solid surface layer. The change in contact angle from the rigid limit to the soft limit appears when the length scale defined by the ratio of surface tension to elastic modulus γ/E reaches the range of molecular interactions.

  11. Gaugings at angles from orientifold reductions

    International Nuclear Information System (INIS)

    Roest, Diederik

    2009-01-01

    We consider orientifold reductions to N= 4 gauged supergravity in four dimensions. A special feature of this theory is that different factors of the gauge group can have relative angles with respect to the electro-magnetic SL(2) symmetry. These are crucial for moduli stabilization and de Sitter vacua. We show how such gaugings at angles generically arise in orientifold reductions.

  12. Custom total occlusal convergence angle sticker fabrication.

    Science.gov (United States)

    Cho, Seok-Hwan; Nagy, William W

    2015-09-01

    This article describes a method of fabricating a custom total occlusal convergence angle sticker with photo editing software and label stickers. The custom total occlusal convergence angle sticker can help clinicians achieve an accurate degree of taper during axial wall reduction of tooth preparation. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  13. Practical evaluation of action-angle variables

    International Nuclear Information System (INIS)

    Boozer, A.H.

    1984-02-01

    A practical method is described for establishing action-angle variables for a Hamiltonian system. That is, a given nearly integrable Hamiltonian is divided into an exactly integrable system plus a perturbation in action-angle form. The transformation of variables, which is carried out using a few short trajectory integrations, permits a rapid determination of trajectory properties throughout a phase space volume

  14. Acute angle closure glaucoma following ileostomy surgery

    Directory of Open Access Journals (Sweden)

    Mariana Meirelles Lopes

    2015-02-01

    Full Text Available Angle-closure glaucoma can be induced by drugs that may cause pupillary dilatation. We report a case of a patient that developed bilateral angle closure glaucoma after an ileostomy surgery because of systemic atropine injection. This case report highlights the importance of a fast ophthalmologic evaluation in diseases with ocular involvement in order to make accurate diagnoses and appropriate treatments.

  15. Does acute passive stretching increase muscle length in children with cerebral palsy?

    Science.gov (United States)

    Theis, Nicola; Korff, Thomas; Kairon, Harvey; Mohagheghi, Amir A

    2013-01-01

    Children with spastic cerebral palsy experience increased muscle stiffness and reduced muscle length, which may prevent elongation of the muscle during stretch. Stretching performed either by the clinician, or children themselves is used as a treatment modality to increase/maintain joint range of motion. It is not clear whether the associated increases in muscle-tendon unit length are due to increases in muscle or tendon length. The purpose was to determine whether alterations in ankle range of motion in response to acute stretching were accompanied by increases in muscle length, and whether any effects would be dependent upon stretch technique. Eight children (6-14 y) with cerebral palsy received a passive dorsiflexion stretch for 5 × 20 s to each leg, which was applied by a physiotherapist or the children themselves. Maximum dorsiflexion angle, medial gastrocnemius muscle and fascicle lengths, and Achilles tendon length were calculated at a reference angle of 10 ° plantarflexion, and at maximum dorsiflexion in the pre- and post-stretch trials. All variables were significantly greater during pre- and post-stretch trials compared to the resting angle, and were independent of stretch technique. There was an approximate 10 ° increase in maximum dorsiflexion post-stretch, and this was accounted for by elongation of both muscle (0.8 cm) and tendon (1.0 cm). Muscle fascicle length increased significantly (0.6 cm) from pre- to post-stretch. The results provide evidence that commonly used stretching techniques can increase overall muscle, and fascicle lengths immediately post-stretch in children with cerebral palsy. © 2013.

  16. Solid angles III. The role of conformers in solid angle calculations

    CSIR Research Space (South Africa)

    White, D

    1995-06-14

    Full Text Available The values of the solid angles Omega for a range of commonly encountered ligands in organometallic chemistry (phosphines, phosphites, amines, arsines and cyclopentadienyl rings) have been determined. The solid angles were derived from a single...

  17. Monitoring of desert dune topography by multi angle sensors

    Science.gov (United States)

    Yun, J.; Kim, J.; Choi, Y.; Yun, H.

    2011-12-01

    Nowadays, the sandy desert is rapidly expanding world widely and results in a lot of risks in the socio-econimical aspects as well as the anthropogenic activities. For example, the increasing occurrences of mineral dust storm which presumably originated from the sandy deserts in northwest China become a serious threat in human activities as well as public health over Far East Asian area as the interpretation by the MODIS analysis (Zhang et al., 2007) and the particle trajectory simulation with HYSPLYT (HYbrid Single-Particle Lagrangian Integrated Trajectory) (Kim et al., 2011) identified. Since the sand dune activity has been recognized as an essential indicator of the progressive desertification, it is important to establish the monitoring method for the variations of topographic properties by the dune activities such as local roughness. Thus it will provide the crucial data about the extent and the transition of sandy desert. For example, it is well known the aerodynamic roughness lengths Zo which can be driven from the specialized sensor such as POLDER (POLarization and Directionality of the Earth's Reflectances) is essential to understand desert dune characteristics. However, for the multi temporal observation of dune fields, the availability of data set to extract Zo is limited. Therefore, we employed MISR (Multi angle imaging Spectro Radiometer) image sequence to extract multi angle topographic parameters such as NDAI (Normalized Difference Angular Index) or the variation of radiance with the viewing geometry which are representing the characteristics of target desert topography instead of Zo. In our approach, NDAI were expanded to the all viewing angles and then compared over the target sandy desert and the surrounding land covers. It showed very strong consistencies according to the land cover type and especially over the dynamic dune fields. On the other hands, the variation of NDAIs of sandy desert combining with the metrological observations were

  18. Laser peripheral iridoplasty for angle-closure.

    Science.gov (United States)

    Ng, Wai Siene; Ang, Ghee Soon; Azuara-Blanco, Augusto

    2012-02-15

    Angle-closure glaucoma is a leading cause of irreversible blindness in the world. Treatment is aimed at opening the anterior chamber angle and lowering the IOP with medical and/or surgical treatment (e.g. trabeculectomy, lens extraction). Laser iridotomy works by eliminating pupillary block and widens the anterior chamber angle in the majority of patients. When laser iridotomy fails to open the anterior chamber angle, laser iridoplasty may be recommended as one of the options in current standard treatment for angle-closure. Laser peripheral iridoplasty works by shrinking and pulling the peripheral iris tissue away from the trabecular meshwork. Laser peripheral iridoplasty can be used for crisis of acute angle-closure and also in non-acute situations.   To assess the effectiveness of laser peripheral iridoplasty in the treatment of narrow angles (i.e. primary angle-closure suspect), primary angle-closure (PAC) or primary angle-closure glaucoma (PACG) in non-acute situations when compared with any other intervention. In this review, angle-closure will refer to patients with narrow angles (PACs), PAC and PACG. We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2011, Issue 12), MEDLINE (January 1950 to January 2012), EMBASE (January 1980 to January 2012), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to January 2012), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). There were no date or language restrictions in the electronic searches for trials. The electronic databases were last searched on 5 January 2012. We included only randomised controlled trials (RCTs) in this review. Patients with narrow angles, PAC or PACG were eligible. We excluded studies that included only patients with acute presentations

  19. Limited flip angle MR imaging: Hemorrhagic applications

    International Nuclear Information System (INIS)

    Drayer, B.P.; Rigamonti, D.; Johnson, P.C.; Spetzler, R.F.; Keller, P.J.; Flom, R.A.; Bird, C.R.; Hodak, J.A.

    1987-01-01

    The authors studied 64 patients with hemorrhagic brain lesions, including vascular malformations (n = 29), hemorrhagic infarctions (n = 9), chronic slit hemorrhagic residua of hypertensive hematoma (n = 10), trauma (n = 8), and gliobastoma multiforme (n = 8). With a 1.5-T MR imaging system, 5-mm sections were obtained at a repetition time of 300 msec (or 500), an echo time of 12.3 msec (or 10 and 40), and a flip angle of 60 0 (or 20 0 ). The limited flip angle study was always extremely sensitive for the detection of hemosiderin. With multiple cavernous angiomas, additional small lesions (in five of 18 patients) were detected only with the limited flip angle technique. The hemosiderin-laden macrophage residua of hemorrhagic infarction and hypertensive hematoma were better seen on limited flip angle images than on T2-weighted spin-echo images. The detection of blood on limited flip angle images permitted the grading of glioma as glioblastoma multiforme

  20. Experimental study of crossing angle collision

    International Nuclear Information System (INIS)

    Chen, T.; Rice, D.; Rubin, D.; Sagan, D.; Tigner, M.

    1993-05-01

    The non-linear coupling due to the beam-beam interaction with crossing angle has been studied. The major effect of a small (∼12mrad) crossing angle is to excite 5Q x ±Q s =integer coupling resonance family on large amplitude particles, which results in bad lifetime. On the CESR, a small crossing angle (∼2.4mr) was created at the IP and a reasonable beam-beam tune-shift was achieved. The decay rate of the beam is measured as a function of horizontal tune with and without crossing angle. The theoretical analysis, simulation and experimental measurements have a good agreement. The resonance strength as a function of crossing angle is also measured

  1. Experimental study of crossing angle collision

    International Nuclear Information System (INIS)

    Chen, T.; Rice, D.; Rubin, D.; Sagan, D.; Tigner, M.

    1993-01-01

    The non-linear coupling due to the beam-beam interaction with crossing angle has been studied. The major effect of a small (∼12mrad) crossing angle is to excite 5Q x ±Q s =integer coupling resonance family on large amplitude particles, which results in bad lifetime. On the CESR, a small crossing angle (∼2.4mr) was created at the IP and a reasonable beam-beam tune-shift was achieved. The decay rate of the beam is measured as a function of horizontal tune with and without crossing angle. The theoretical analysis, simulation and experimental measurements have a good agreement. The resonance strength as a function of crossing angle is also measured

  2. Joint angles of the ankle, knee, and hip and loading conditions during split squats.

    Science.gov (United States)

    Schütz, Pascal; List, Renate; Zemp, Roland; Schellenberg, Florian; Taylor, William R; Lorenzetti, Silvio

    2014-06-01

    The aim of this study was to quantify how step length and the front tibia angle influence joint angles and loading conditions during the split squat exercise. Eleven subjects performed split squats with an additional load of 25% body weight applied using a barbell. Each subject's movements were recorded using a motion capture system, and the ground reaction force was measured under each foot. The joint angles and loading conditions were calculated using a cluster-based kinematic approach and inverse dynamics modeling respectively. Increases in the tibia angle resulted in a smaller range of motion (ROM) of the front knee and a larger ROM of the rear knee and hip. The external flexion moment in the front knee/hip and the external extension moment in the rear hip decreased as the tibia angle increased. The flexion moment in the rear knee increased as the tibia angle increased. The load distribution between the legs changed squat execution was varied. Our results describing the changes in joint angles and the resulting differences in the moments of the knee and hip will allow coaches and therapists to adapt the split squat exercise to the individual motion and load demands of athletes.

  3. Stride angle as a novel indicator of running economy in well-trained runners.

    Science.gov (United States)

    Santos-Concejero, Jordan; Tam, Nicholas; Granados, Cristina; Irazusta, Jon; Bidaurrazaga-Letona, Iraia; Zabala-Lili, Jon; Gil, Susana M

    2014-07-01

    The main purpose of this study was to investigate the relationship between a novel biomechanical variable, the stride angle, and running economy (RE) in a homogeneous group of long-distance athletes. Twenty-five well-trained male runners completed 4-minute running stages on a treadmill at different set velocities. During the test, biomechanical variables such as stride angle, swing time, ground contact time, stride length, stride frequency, and the different sub-phases of ground contact were recorded using an optical measurement system. VO2 values at velocities below the lactate threshold were measured to calculate RE. Stride angle was negatively correlated with RE at every speed (p contact time and running performance according to the best 10-km race time (p ≤ 0.05, moderate and large effect sizes). Last, stride angle was correlated with ground contact time at every speed (p angle allows runners to minimize contact time during ground contact, whereby facilitating a better RE. Coaches and/or athletes may find stride angle a useful and easily obtainable measure to track and make alterations to running technique, because changes in stride angle may influence the energy cost of running and lead to improved performance.

  4. String matching with variable length gaps

    DEFF Research Database (Denmark)

    Bille, Philip; Gørtz, Inge Li; Vildhøj, Hjalte Wedel

    2012-01-01

    We consider string matching with variable length gaps. Given a string T and a pattern P consisting of strings separated by variable length gaps (arbitrary strings of length in a specified range), the problem is to find all ending positions of substrings in T that match P. This problem is a basic...

  5. Heparin's solution structure determined by small-angle neutron scattering.

    Science.gov (United States)

    Rubinson, Kenneth A; Chen, Yin; Cress, Brady F; Zhang, Fuming; Linhardt, Robert J

    2016-12-01

    Heparin is a linear, anionic polysaccharide that is widely used as a clinical anticoagulant. Despite its discovery 100 years ago in 1916, the solution structure of heparin remains unknown. The solution shape of heparin has not previously been examined in water under a range of concentrations, and here is done so in D2 O solution using small-angle neutron scattering (SANS). Solutions of 10 kDa heparin-in the millimolar concentration range-were probed with SANS. Our results show that when sodium concentrations are equivalent to the polyelectrolyte's charge or up to a few hundred millimoles higher, the molecular structure of heparin is compact and the shape could be well modeled by a cylinder with a length three to four times its diameter. In the presence of molar concentrations of sodium, the molecule becomes extended to nearly its full length estimated from reported X-ray measurements on stretched fibers. This stretched form is not found in the presence of molar concentrations of potassium ions. In this high-potassium environment, the heparin molecules have the same shape as when its charges were mostly protonated at pD ≈ 0.5, that is, they are compact and approximately half the length of the extended molecules. © 2016 Wiley Periodicals, Inc.

  6. Modified angle's classification for primary dentition

    Directory of Open Access Journals (Sweden)

    Kaushik Narendra Chandranee

    2017-01-01

    Full Text Available Aim: This study aims to propose a modification of Angle's classification for primary dentition and to assess its applicability in children from Central India, Nagpur. Methods: Modification in Angle's classification has been proposed for application in primary dentition. Small roman numbers i/ii/iii are used for primary dentition notation to represent Angle's Class I/II/III molar relationships as in permanent dentition, respectively. To assess applicability of modified Angle's classification a cross-sectional preschool 2000 children population from central India; 3–6 years of age residing in Nagpur metropolitan city of Maharashtra state were selected randomly as per the inclusion and exclusion criteria. Results: Majority 93.35% children were found to have bilateral Class i followed by 2.5% bilateral Class ii and 0.2% bilateral half cusp Class iii molar relationships as per the modified Angle's classification for primary dentition. About 3.75% children had various combinations of Class ii relationships and 0.2% children were having Class iii subdivision relationship. Conclusions: Modification of Angle's classification for application in primary dentition has been proposed. A cross-sectional investigation using new classification revealed various 6.25% Class ii and 0.4% Class iii molar relationships cases in preschool children population in a metropolitan city of Nagpur. Application of the modified Angle's classification to other population groups is warranted to validate its routine application in clinical pediatric dentistry.

  7. Small angle neutron scattering of micro- and nanostructured materials

    International Nuclear Information System (INIS)

    Trinker, M.

    2006-05-01

    In this work studies of micro- and nanostructured materials by means of neutron scattering techniques are presented. The first part contains the theory of neutron scattering by structures in condensed matter necessary for the understanding of the experimental results. The method of small angle neutron scattering (SANS) is applied to a sample of highly irradiated SiC/SiCf composite. These materials play an important role in concepts for future fusion reactors. Radiation induced structural changes after high-dose irradiation in the spallation target of the SINQ neutron source, Switzerland, are analyzed. For testing instruments and methods used in ultra-small angle neutron scattering (USANS) artificial microstructured samples fabricated from silicon are particularly suitable. Because of the known structure parameters and the model-like character of such samples the performance of the instruments involved and the models used for interpretation of the scattering data can be tested. The development and fabrication of a series of such silicon gratings at the Center for Micro- and Nanostructures (ZMNS) of the Vienna University of Technology are described. The following USANS measurements at the instrument S18 of the Institute Laue-Langevin, Grenoble, which is run by the Atomic Institute of the Austrian Universities, and the instrument itself are presented. Subsequently the results are compared to those of the newly developed spinecho small angle neutron scattering technique (SESANS) at the Delft University of Technology. The complementarity of both techniques is demonstrated by means of the scattering data obtained from the silicon gratings. A method for the direct reconstruction of one-dimensional scattering length density distributions is applied to the USANS scattering data of the silicon microstructures. The results are compared to those obtained from scanning electron microscopy and the applicability of the method to USANS scattering data for the reconstruction of one

  8. Patellar angle in Osgood-Schlatter disease.

    Science.gov (United States)

    Sen, R K; Sharma, L R; Thakur, S R; Lakhanpal, V P

    1989-02-01

    A new patellar angle is described in lateral radiographs of the knee joint. One line is drawn along the articular surface of the patella and another from the end of the inferior articular cartilage to the patellar apex. The angle formed by these two lines averaged 33 degrees in 68 knees joints afflicted with Osgood-Schlatter disease and 47 degrees in 71 age-matched controls and 198 adult controls. The small angle in Osgood-Schlatter disease is proposed to be an important factor in the pathogenesis of the traction apophysitis.

  9. Computing angle of arrival of radio signals

    Science.gov (United States)

    Borchardt, John J.; Steele, David K.

    2017-11-07

    Various technologies pertaining to computing angle of arrival of radio signals are described. A system that is configured for computing the angle of arrival of a radio signal includes a cylindrical sheath wrapped around a cylindrical object, where the cylindrical sheath acts as a ground plane. The system further includes a plurality of antennas that are positioned about an exterior surface of the cylindrical sheath, and receivers respectively coupled to the antennas. The receivers output measurements pertaining to the radio signal. A processing circuit receives the measurements and computes the angle of arrival of the radio signal based upon the measurements.

  10. Small angle scattering of X radiation and slow neutrons in structural analyses of amorphous solids

    International Nuclear Information System (INIS)

    Kostorz, G.

    1980-01-01

    Small angle scattering of x radiation and slow neutrons allows to detect inhomogeneities of the dimension of ten to some thousands of Angstroem by the difference in the scattering length density. The progress made during recent years in the development of apparatusses has created the possibility of solving very complicated problems. A first outline shows that in separation processes as well as in investigating extended defects the method of small angle scattering may provide valuable contributions to the analysis of the non-crystalline state

  11. Parametric study on supersonic flutter of angle-ply laminated plates using shear deformable finite element method

    Science.gov (United States)

    Xia, Wei; Ni, Qiao

    2011-10-01

    The influence of fiber orientation, flow yaw angle and length-to-thickness ratio on flutter characteristics of angle-ply laminated plates in supersonic flow is studied by finite element approach. The structural model is established using the Reissner-Mindlin theory in which the transverse shear deformation is considered. The aerodynamic pressure is evaluated by the quasi-steady first-order piston theory. The equations of motion are formulated based on the principle of virtual work. With the harmonic motion assumption, the flutter boundary is determined by solving a series of complex eigenvalue problems. Numerical study shows that (1) The flutter dynamic pressure and the coalescence of flutter modes depend on fiber orientation, flow yaw angle and length-to-thickness ratio; (2) The laminated plate with all fibers aligned with the flow direction gives the highest flutter dynamic pressure, but a slight yawing of the flow from the fiber orientation results in a sharp decrease of the flutter dynamic pressure; (3) The angle-ply laminated plate with fiber orientation angle equal to flow yaw angle gives high flutter dynamic pressure, but not the maximum flutter dynamic pressure; (4) With the decrease of length-to-thickness ratio, an adverse effect due to mode transition on the flutter dynamic pressure is found.

  12. Angles-Only Navigation System for Nanosatellites

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of the proposed work is to develop and implement an angles-only relative navigation system on hardware suitable for deployment on nanosatellites or...

  13. Directional Wide-Angle Range Finder (DWARF)

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation, the Directional Wide-Angle Range Finder (DWARF) is the creation of a laser range-finder with a wide field-of-view (FOV) and a directional...

  14. Low angle X-ray scattering

    International Nuclear Information System (INIS)

    Torrianni, I.L.

    1983-01-01

    The theoretical and experimental problems appearing in diffraction experiments at very low angles by several kinds of materials are discussed. The importance of synchrotron radiation in such problems is shown. (L.C.) [pt

  15. Beam Tilt-Angle Estimation for Monopole End-Fire Array Mounted on a Finite Ground Plane

    OpenAIRE

    Cao, Jia; Xue, Zhenghui; Cao, Meng

    2015-01-01

    A modified method for the beam tilt-angle estimation of monopole end-fire array mounted on finite ground plane is proposed. In the simplified model, the monopole array and ground plane are approximated to two line sources of transverse and longitudinal electric current, respectively. It is deduced that the beam tilt angle is a function about the length of ground plane in front of array Lg, the length of monopole array La, and the phase constant βα. After verifying the optimizing principle of ...

  16. Prompt angle measurements with large aperture scintillators

    International Nuclear Information System (INIS)

    Schneid, E.J.

    1976-01-01

    A technique is described for the measurement of particle trajectory angle through a pair of scintillator tiles. Signal processing provides an analog signal proportional to the tangent of the angle between the particle trajectory and the axis normal to the pair of tiles. This signal is readily available for use in fast decision logic if required: i.e., sorting energy loss signals from the tiles according to geometrical factors or restricting the events to be analyzed on the basis of incident direction

  17. Small-angle neutron-scattering experiments

    International Nuclear Information System (INIS)

    Hardy, A.D.; Thomas, M.W.; Rouse, K.D.

    1981-04-01

    A brief introduction to the technique of small-angle neutron scattering is given. The layout and operation of the small-angle scattering spectrometer, mounted on the AERE PLUTO reactor, is also described. Results obtained using the spectrometer are presented for three materials (doped uranium dioxide, Magnox cladding and nitrided steel) of interest to Springfields Nuclear Power Development Laboratories. The results obtained are discussed in relation to other known data for these materials. (author)

  18. Axial vector mass spectrum and mixing angles

    International Nuclear Information System (INIS)

    Caffarelli, R.V.; Kang, K.

    1976-01-01

    Spectral sum rules of the axial-vector current and axial-vector current-pseudoscalar field are used to study the axial-vector mass spectrum and mixing angles, as well as the decay constants and mixing angles of the pseudoscalar mesons. In general, the result is quite persuasive for the existence of the Jsup(PC) = 1 ++ multiplet in which one has a canonical D-E mixing. (Auth.)

  19. Sharper angle, higher risk? The effect of cutting angle on knee mechanics in invasion sport athletes.

    Science.gov (United States)

    Schreurs, Mervin J; Benjaminse, Anne; Lemmink, Koen A P M

    2017-10-03

    Cutting is an important skill in team-sports, but unfortunately is also related to non-contact ACL injuries. The purpose was to examine knee kinetics and kinematics at different cutting angles. 13 males and 16 females performed cuts at different angles (45°, 90°, 135° and 180°) at maximum speed. 3D kinematics and kinetics were collected. To determine differences across cutting angles (45°, 90°, 135° and 180°) and sex (female, male), a 4×2 repeated measures ANOVA was conducted followed by post hoc comparisons (Bonferroni) with alpha level set at α≤0.05a priori. At all cutting angles, males showed greater knee flexion angles than females (pknee flexion -42.53°±8.95°, females decreased their knee flexion angle from -40.6°±7.2° when cutting at 45° to -36.81°±9.10° when cutting at 90°, 135° and 180° (pKnee flexion moment decreased for both sexes when cutting towards sharper angles (pknee valgus moments than females. For both sexes, knee valgus moment increased towards the sharper cutting angles and then stabilized compared to the 45° cutting angle (pknee kinematics and kinetics. Sharper cutting angles place the knee more at risk. However, females and males handle this differently, which has implications for injury prevention. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Short Rayleigh Length Free Electron Lasers

    CERN Document Server

    Crooker, P P; Armstead, R L; Blau, J

    2004-01-01

    Conventional free electron laser (FEL) oscillators minimize the optical mode volume around the electron beam in the undulator by making the resonator Rayleigh length about one third of the undulator length. This maximizes gain and beam-mode coupling. In compact configurations of high-power infrared FELs or moderate power UV FELs, the resulting optical intensity can damage the resonator mirrors. To increase the spot size and thereby reduce the optical intensity at the mirrors below the damage threshold, a shorter Rayleigh length can be used, but the FEL interaction is significantly altered. A new FEL interaction is described and analyzed with a Rayleigh length that is only one tenth the undulator length, or less. The effect of mirror vibration and positioning are more critical in the short Rayleigh length design, but we find that they are still within normal design tolerances.

  1. Applications of the scoliosis width-to-length ratio for guiding selection of the surgical approaches of degenerative lumbar scoliosis.

    Science.gov (United States)

    Jiang, Chuan-jie; Yang, Yong-jun; Zhou, Ji-ping; Yao, Shu-qiang; Yang, Kai; Wu, Rui; Tan, Yuan-chao

    2016-02-01

    There does not exist a comprehensive parameter for guiding selection of short or long segment fusion for degenerative lumbar scoliosis (DLS). The aim of our study was to investigate the applications of the width-to-length ratio in guiding selection of the surgical approaches for DLS. A retrospective analysis was performed of 142 patients with DLS who underwent operative treatments from July 2000 to January 2012. The scoliosis width-to-length ratios were measured and used as a grouping criterion of surgical approaches. The Oswestry disability index (ODI) was used to evaluate the clinical outcomes. Radiological parameters such as Cobb's angle of main curve, Cobb's angle of compensatory curve were all measured. For patients with width-to-length ratio less than 0.36, the short segment group had better short-term postoperative outcomes with regard to Cobb's angle of main curve, Cobb's angle of compensatory curve and ODI scores compared to the long segment group. However, for patients with width-to-length ratio greater than 0.36, the postoperative outcomes for the long segment group were better compared to the short segment group. The scoliosis width-to-length ratio can provide a comprehensive preoperative assessment of the severity of the DLS and guiding selection of a therapeutic treatment regimen. Further studies with a larger number of samples and longer term of follow up are warranted.

  2. Solar cell angle of incidence corrections

    Science.gov (United States)

    Burger, Dale R.; Mueller, Robert L.

    1995-01-01

    Literature on solar array angle of incidence corrections was found to be sparse and contained no tabular data for support. This lack along with recent data on 27 GaAs/Ge 4 cm by 4 cm cells initiated the analysis presented in this paper. The literature cites seven possible contributors to angle of incidence effects: cosine, optical front surface, edge, shadowing, UV degradation, particulate soiling, and background color. Only the first three are covered in this paper due to lack of sufficient data. The cosine correction is commonly used but is not sufficient when the incident angle is large. Fresnel reflection calculations require knowledge of the index of refraction of the coverglass front surface. The absolute index of refraction for the coverglass front surface was not known nor was it measured due to lack of funds. However, a value for the index of refraction was obtained by examining how the prediction errors varied with different assumed indices and selecting the best fit to the set of measured values. Corrections using front surface Fresnel reflection along with the cosine correction give very good predictive results when compared to measured data, except there is a definite trend away from predicted values at the larger incident angles. This trend could be related to edge effects and is illustrated by a use of a box plot of the errors and by plotting the deviation of the mean against incidence angle. The trend is for larger deviations at larger incidence angles and there may be a fourth order effect involved in the trend. A chi-squared test was used to determine if the measurement errors were normally distributed. At 10 degrees the chi-squared test failed, probably due to the very small numbers involved or a bias from the measurement procedure. All other angles showed a good fit to the normal distribution with increasing goodness-of-fit as the angles increased which reinforces the very small numbers hypothesis. The contributed data only went to 65 degrees

  3. Small angle neutron scattering from high impact polystyrene

    International Nuclear Information System (INIS)

    Pringle, O.A.

    1981-01-01

    High impact polystyrene (HIPS) is a toughened plastic composed of a polystyrene matrix containing a few percent rubber in the form of dispersed 0.1 to 10 micron diameter rubber particles. Some commercial formulations of HIPS include the addition of a few percent mineral oil, which improves the toughness of the plastic. Little is known about the mechanism by which the mineral oil helps toughen the plastic. It is hypothesized that the oil is distributed only in the rubber particles, but whether this hypothesis is correct was not known prior to this work. The size of the rubber particles in HIPS and their neutron scattering length density contrast with the polystyrene matrix cause HIPS samples to scatter neutrons at small angles. The variation of this small angle neutron scattering (SANS) signal with mineral oil content has been used to determine the location of the oil in HIPS. The SANS spectrometer at the University of Missouri Research Reactor Facility (MURR) was used to study plastic samples similar in composition to commercial HIPS. The MURR SANS spectrometer is used to study the small angle scattering of a vertical beam of 4.75 A neutrons from solid and liquid samples. The scattered neutrons are detected in a 54 x 60 cm 2 position sensitive detector designed and built at MURR. A series of plastic samples of varying rubber and oil content and different rubber domain sizes and shapes were examined on the MURR SANS spectrometer. Analysis of the scattering patterns showed that the mineral oil is about eight to ten times more likely to be found in the rubber particles than in the polystyrene matrix. This result confirmed the hypothesis that the mineral oil is distributed primarily in the rubber particles

  4. Small-angle neutron scattering at pulsed spallation sources

    International Nuclear Information System (INIS)

    Seeger, P.A.; Hjelm, R.P. Jr.

    1990-01-01

    The importance of small-angle neutron scattering (SANS) in biological, chemical, physical, and engineering research mandates that all intense neutron sources be equipped with SANS instruments. Four existing instruments are described, and the general differences between pulsed-source and reactor-based instrument designs are discussed. The basic geometries are identical, but dynamic range is achieved by using a broad band of wavelengths (with time-of-flight analysis) rather than by moving the detector. This allows a more optimized collimation system. Data acquisition requirements at a pulsed source are more severe, requiring large, fast histogramming memories. Data reduction is also more complex, as all wave length-dependent and angle-dependent backgrounds and non-linearities must be accounted for before data can be transformed to intensity vs Q. A comparison is shown between the Los Alamos pulsed instrument and D-11 (Institute Laue-Langevin), and examples from the four major topics of the conference are shown. The general conclusion is that reactor-based instruments remain superior at very low Q or if only a narrow range of Q is required, but that the current generation of pulsed-source instruments is competitive at moderate Q and may be faster when a wide range of Q is required. In principle, a user should choose which facility to use on the basis of optimizing the experiment; in practice the tradeoffs are not severe and the choice is usually made on the basis of availability

  5. Angled-focused 45 MHz PMN-PT single element transducer for intravascular ultrasound imaging.

    Science.gov (United States)

    Yoon, Sangpil; Williams, Jay; Kang, Bong Jin; Yoon, Changhan; Cabrera-Munoz, Nestor; Jeong, Jong Seob; Lee, Sang Goo; Shung, K Kirk; Kim, Hyung Ham

    2015-06-01

    A transducer with an angled and focused aperture for intravascular ultrasound imaging has been developed. The acoustic stack for the angled-focused transducer was made of PMN-PT single crystal with one matching layer, one protective coating layer, and a highly damped backing layer. It was then press-focused to a desired focal length and inserted into a thin needle housing with an angled tip. A transducer with an angled and unfocused aperture was also made, following the same fabrication procedure, to compare the performance of the two transducers. The focused and unfocused transducers were tested to measure their center frequencies, bandwidths, and spatial resolutions. Lateral resolution of the angled-focused transducer (AFT) improved more than two times compared to that of the angled-unfocused transducer (AUT). A tissue-mimicking phantom in water and a rabbit aorta tissue sample in rabbit blood were scanned using AFT and AUT. Imaging with AFT offered improved contrast, over imaging with AUT, of the tissue-mimicking phantom and the rabbit aorta tissue sample by 23 dB and 8 dB, respectively. The results show that AFT has strong potential to provide morphological and pathological information of coronary arteries with high resolution and high contrast.

  6. Characterization of nano-structure by small-angle X-ray and neutron scattering

    International Nuclear Information System (INIS)

    Ohnuma, Masato

    2017-01-01

    This paper outlines the cases when small-angle X-ray scattering method and small-angle neutron scattering method in transmission arrangement were applied to heterogeneity with low-volume rate (10% or below), such as nano-sized deposits and trace defects. In particular, it explains not only general analysis, but also the possibility of use of the small angle scattering method as a simple inspection method in nanostructure evaluation, as well as correspondence of small-angle scattering method with powder diffraction method in crystal structure evaluation. From the small-angle scattering profiles of a series of sample groups, we can judge which sample has the smallest nanostructure, by only comparing profiles without analysis. The object to be measured is a heterogeneous structure (void, second phase, crack, etc.) having a diameter of about 1 to several hundred nm present in a material. This paper also outlines the usual small-angle scattering analysis method, as well as further analysis using the difference between X-ray and neutron on scattering length contrast. (A.O.)

  7. Multilevel Models for the Analysis of Angle-Specific Torque Curves with Application to Master Athletes

    Science.gov (United States)

    Carvalho, Humberto M

    2015-01-01

    The aim of this paper was to outline a multilevel modeling approach to fit individual angle-specific torque curves describing concentric knee extension and flexion isokinetic muscular actions in Master athletes. The potential of the analytical approach to examine between individual differences across the angle-specific torque curves was illustrated including between-individuals variation due to gender differences at a higher level. Torques in concentric muscular actions of knee extension and knee extension at 60º·s−1 were considered within a range of motion between 5º and 85º (only torques “truly” isokinetic). Multilevel time series models with autoregressive covariance structures with standard multilevel models were superior fits compared with standard multilevel models for repeated measures to fit angle-specific torque curves. Third and fourth order polynomial models were the best fits to describe angle-specific torque curves of isokinetic knee flexion and extension concentric actions, respectively. The fixed exponents allow interpretations for initial acceleration, the angle at peak torque and the decrement of torque after peak torque. Also, the multilevel models were flexible to illustrate the influence of gender differences on the shape of torque throughout the range of motion and in the shape of the curves. The presented multilevel regression models may afford a general framework to examine angle-specific moment curves by isokinetic dynamometry, and add to the understanding mechanisms of strength development, particularly the force-length relationship, both related to performance and injury prevention. PMID:26839603

  8. Characterization of spreadability of nonaqueous ethylcellulose gel matrices using dynamic contact angle.

    Science.gov (United States)

    Chow, Keat Theng; Chan, Lai Wah; Heng, Paul W S

    2008-08-01

    This study reports the characterization of spreadability of nonaqueous ethylcellulose (EC) gel matrices intended for topical drug delivery using a newly developed method based on dynamic contact angle. EC solutions were prepared using three grades of EC and propylene glycol dicaprylate/dicaprate. Dynamic contact angles of sessile drops of EC solutions on silicone elastomer were measured using a dynamic contact angle analyzer equipped with axisymmetric drop shape analysis-profile. Roughness of silicone elastomer, viscosity of EC solutions and compressibility of semisolid EC gels were determined by the atomic force microscope, cone-and-plate rheometer and tensile tester, respectively. The silicone elastomer employed as a substrate was demonstrated to have similar hydrophilic/lipophilic properties as the human skin. Spreadability of EC solutions was dependent on EC concentration, polymeric chain length and polydispersity. EC gel spreadability was governed by viscosity and the extent of gel-substrate interaction. From the apparent contact angle values, most EC gel formulations tested were found to be moderately spreadable. Linear correlation observed between spreading parameter and compressibility of EC gel verified the applicability of dynamic contact angle to characterize EC gel spreadability. Thus, the feasibility of employing dynamic contact angle as an alternative technique to measure gel spreadability was demonstrated. The spreadability demonstrated by EC gel would facilitate application on the skin indicating its potential usefulness as a topical dosage form.

  9. Information, polarization and term length in democracy

    DEFF Research Database (Denmark)

    Schultz, Christian

    2008-01-01

    accountable, but the re-election incentive leads to policy-distortion as the government seeks to manipulate swing voters' beliefs to make its ideology more popular. This creates a trade-off: A short term length improves accountability but gives distortions. A short term length is best for swing voters when......This paper considers term lengths in a representative democracy where the political issue divides the population on the left-right scale. Parties are ideologically different and better informed about the consequences of policies than voters are. A short term length makes the government more...

  10. Measurement of subpicosecond bunch lengths using coherent Smith-Purcell radiation

    Directory of Open Access Journals (Sweden)

    S. E. Korbly

    2006-02-01

    Full Text Available We report the use of coherent Smith-Purcell radiation to measure the bunch length of femtosecond-scale, 15 MeV electron bunches produced by a 17 GHz rf accelerator. The Smith-Purcell radiation was produced by passing a train of electron bunches above a metal grating. The radiation was verified as Smith-Purcell radiation by measuring the resonance condition, dependence on beam current, and dependence on beam height above the grating. Measurements of the intensity of the radiation vs emission angle were analyzed to obtain the bunch length. The accelerator was operated in two different modes, producing bunches that were determined to have bunch lengths of 600 and 1000±200  fs. These nondestructive bunch length measurements were found to agree well with an independent, but destructive, measurement using a microwave deflecting cavity.

  11. On the neutron scattering length density of proteins in H2O/D2O

    Science.gov (United States)

    Efimova, Y. M.; van Well, A. A.; Hanefeld, U.; Wierczinski, B.; Bouwman, W. G.

    2004-07-01

    The structure of the protein layers adsorbed at different interfaces can be determined by using neutron-reflection and small-angle neutron scattering. For highlighting the adsorbed protein layer at the interface, the technique of contrast-variation by changing the H2O/D2O ratio, is often used. For determining the scattering length density, both the protein volume in solution and the total scattering length of the protein is needed. The volume is calculated from the amino-acid sequence. For calculating the scattering length, the H/D exchange of the labile protons of the protein should be taken into account. For monitoring the H/D exchange, Positive Electrospray Ionization Mass Spectroscopy was applied. We compare experimental results for the exchange in lysozyme and β-casein with theoretical calculations. The importance of using the correct protein scattering-length density is elucidated by simultaneous model fitting to neutron reflection data at different water contrasts.

  12. On the neutron scattering length density of proteins in H2O/D2O

    International Nuclear Information System (INIS)

    Efimova, Y.M.; Well, A.A. van; Hanefeld, U.; Wierczinski, B.; Bouwman, W.G.

    2004-01-01

    The structure of the protein layers adsorbed at different interfaces can be determined by using neutron-reflection and small-angle neutron scattering. For highlighting the adsorbed protein layer at the interface, the technique of contrast-variation by changing the H 2 O/D 2 O ratio, is often used. For determining the scattering length density, both the protein volume in solution and the total scattering length of the protein is needed. The volume is calculated from the amino-acid sequence. For calculating the scattering length, the H/D exchange of the labile protons of the protein should be taken into account. For monitoring the H/D exchange, Positive Electrospray Ionization Mass Spectroscopy was applied. We compare experimental results for the exchange in lysozyme and β-casein with theoretical calculations. The importance of using the correct protein scattering-length density is elucidated by simultaneous model fitting to neutron reflection data at different water contrasts

  13. Fractal approach in petrology: Combining ultra small angle (USANS), and small angle neutron scattering (SANS)

    International Nuclear Information System (INIS)

    Lo Celso, F.; Triolo, R.; Triolo, F.; Triolo, A.; Lin, J.S.; Lucido, G.

    2000-01-01

    Ultra small angle neutron scattering instruments have recently covered the gap between the size resolution available with conventional intermediate angle neutron scattering and small angle neutron scattering instruments on one side and optical microscopy on the other side. Rocks showing fractal behavior in over two decades of momentum transfer and seven orders of magnitude of intensity are examined and fractal parameters are extracted from the combined USANS and SANS curves

  14. Fractal Approach in Petrology: Combining Ultra-Small Angle (USANS) and Small Angle Neutron Scattering (SANS)

    International Nuclear Information System (INIS)

    LoCelso, F.; Triolo, F.; Triolo, A.; Lin, J.S.; Lucido, G.; Triolo, R.

    1999-01-01

    Ultra small angle neutron scattering instruments have recently covered the gap between the size resolution available with conventional intermediate angle neutron scattering and small angle neutron scattering instruments on one side and optical microscopy on the other side. Rocks showing fractal behavior in over two decades of momentum transfer and seven orders of magnitude of intensity are examined and fractal parameters are extracted from the combined USANS and SANS curves

  15. New comparative clinical and biometric findings between acute primary angle-closure and glaucomatous eyes with narrow angle

    Directory of Open Access Journals (Sweden)

    Rafael Vidal Mérula

    2010-12-01

    Full Text Available Purpose: To compare, clinically and biometrically, affected and fellow acute primary angle-closure (APAC eyes and glaucomatous eyes with narrow angle (NA. Methods: Comparative case series; 30 patients with APAC and 27 glaucomatous patients with NA were evaluated. Keratometry (K, central corneal thickness (CCT, lens thickness (LT, axial length (AL and anterior chamber depth (ACD were measured. Parameters defined as lens posisiton (LP and relative lens position (RLP were calculated. Results: Biometric difference between APAC-affected and fellow eyes was found only in LP (P=0.046. When fellow eyes were compared to glaucomatous eyes with NA, differences were found in ACD (P=0.009, AL (P=0.010, and LT/AL (P=0.005. The comparison between APAC-affected and glaucomatous eyes with NA showed significant differences in almost all biometric parameters, except for LT (P=0.148 and RLP (P=0.374. We found that the logistic regression model (LRM, built with three parameters (K, CCT and LT/AL, higher than 0.334 could be a reasonable instrument to differentiate APAC eyes from glaucomatous eyes with NA. Conclusions: This study showed that APAC-affected and fellow eyes have similar biometric features, and glaucomatous eyes with NA have a less crowded anterior segment. The LRM built showed promising results in distinguishing APAC from glaucomatous eyes with NA.

  16. New comparative clinical and biometric findings between acute primary angle-closure and glaucomatous eyes with narrow angle.

    Science.gov (United States)

    Mérula, Rafael Vidal; Cronemberger, Sebastião; Diniz Filho, Alberto; Calixto, Nassim

    2010-01-01

    To compare, clinically and biometrically, affected and fellow acute primary angle-closure (APAC) eyes and glaucomatous eyes with narrow angle (NA). Comparative case series; 30 patients with APAC and 27 glaucomatous patients with NA were evaluated. Keratometry (K), central corneal thickness (CCT), lens thickness (LT), axial length (AL) and anterior chamber depth (ACD) were measured. Parameters defined as lens posisiton (LP) and relative lens position (RLP) were calculated. Biometric difference between APAC-affected and fellow eyes was found only in LP (P=0.046). When fellow eyes were compared to glaucomatous eyes with NA, differences were found in ACD (P=0.009), AL (P=0.010), and LT/AL (P=0.005). The comparison between APAC-affected and glaucomatous eyes with NA showed significant differences in almost all biometric parameters, except for LT (P=0.148) and RLP (P=0.374). We found that the logistic regression model (LRM), built with three parameters (K, CCT and LT/AL), higher than 0.334 could be a reasonable instrument to differentiate APAC eyes from glaucomatous eyes with NA. This study showed that APAC-affected and fellow eyes have similar biometric features, and glaucomatous eyes with NA have a less crowded anterior segment. The LRM built showed promising results in distinguishing APAC from glaucomatous eyes with NA.

  17. Choosing a proper working length can improve the lifespan of locked plates. A biomechanical study.

    Science.gov (United States)

    Hoffmeier, Konrad L; Hofmann, Gunther O; Mückley, Thomas

    2011-05-01

    It is hypothesized that the working length influences the implants fatigue behavior. However, few studies addressing this issue came to contrary results. Therefore, we tested systematically the influence of working length and implant material on the plate's endurance. We used an artificial model providing the substantial angle and length conditions of a human femur. A fracture gap of 10mm was bridged with identical shaped plate implants made of stainless steel and grade-2 titanium. The fatigue strength was tested for a short, medium and long working length. Aiming at an implant failure within 80,000 loading cycles the upper load threshold was set to 265N for the titanium plates and to 420N for the steel plates. The lower load threshold was -20N for both plates. For the steel plates there was no correlation between fatigue strength and working length. The construct stiffness did not differ at short and medium working length and was reduced by 10% (P=0.047) at long working length. For the titanium plates the fatigue strength tends to increase with the working length but this correlation was not significant (τ=0.417, P=0.051). Further there was a negative correlation between working length and construct stiffness (τ=0.552; P=0.01). The working length has no appreciable effect on the endurance of the steel plates. Compared to the grade 2-titanium plates the stainless steel plates sustain a larger amount of cyclic load. However, for the titanium plates a larger working length tends to improve the endurance. Copyright © 2010 Elsevier Ltd. All rights reserved.

  18. Characterization of porous materials using combined small-angle X-ray and neutron scattering techniques

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Naiping; Borkar, Neha; Kohls, Doug; Schaefer, Dale W. (UCIN)

    2014-09-24

    A combination of ultra small angle X-ray scattering (USAXS) and ultra small angle neutron scattering (USANS) is used to characterize porous materials. The analysis methods yield quantitative information, including the mean skeletal chord length, mean pore chord length, skeletal density, and composition. A mixed cellulose ester (MCE) membrane with a manufacturer-labeled pore size of 0.1 {mu}m was used as a model to elucidate the specifics of the method. Four approaches describing four specific scenarios (different known parameters and form of the scattering data) are compared. Pore chords determined using all four approaches are in good agreement with the scanning electron microscopy estimates but are larger than the manufacturer's nominal pore size. Our approach also gives the average chord of the skeletal solid (struts) of the membrane, which is also consistent for all four approaches. Combined data from USAXS and USANS gives the skeletal density and the strut composition.

  19. Characterization of porous materials using combined small-angle X-ray and neutron scattering techniques

    International Nuclear Information System (INIS)

    Hu, Naiping; Borkar, Neha; Kohls, Doug; Schaefer, Dale W.

    2012-01-01

    A combination of ultra small angle X-ray scattering (USAXS) and ultra small angle neutron scattering (USANS) is used to characterize porous materials. The analysis methods yield quantitative information, including the mean skeletal chord length, mean pore chord length, skeletal density, and composition. A mixed cellulose ester (MCE) membrane with a manufacturer-labeled pore size of 0.1 μm was used as a model to elucidate the specifics of the method. Four approaches describing four specific scenarios (different known parameters and form of the scattering data) are compared. Pore chords determined using all four approaches are in good agreement with the scanning electron microscopy estimates but are larger than the manufacturer's nominal pore size. Our approach also gives the average chord of the skeletal solid (struts) of the membrane, which is also consistent for all four approaches. Combined data from USAXS and USANS gives the skeletal density and the strut composition.

  20. Graphene spin valve: An angle sensor

    Energy Technology Data Exchange (ETDEWEB)

    Iqbal, Muhammad Zahir, E-mail: zahir.upc@gmail.com [Faculty of Engineering Sciences, GIK Institute of Engineering Sciences and Technology, Topi 23640, Khyber Pakhtunkhwa (Pakistan); Hussain, Ghulam [Faculty of Engineering Sciences, GIK Institute of Engineering Sciences and Technology, Topi 23640, Khyber Pakhtunkhwa (Pakistan); Siddique, Salma [Department of Bioscience & Biotechnology, Sejong University, Seoul 143-747 (Korea, Republic of); Iqbal, Muhammad Waqas [Department of Physics, Riphah Institute of Computing and Applied Sciences (RICAS), Riphah International University, Lahore (Pakistan)

    2017-06-15

    Graphene spin valves can be optimized for various spintronic applications by tuning the associated experimental parameters. In this work, we report the angle dependent magnetoresistance (MR) in graphene spin valve for different orientations of applied magnetic field (B). The switching points of spin valve signals show a clear shift towards higher B for each increasing angle of the applied field, thus sensing the response for respective orientation of the magnetic field. The angular variation of B shifts the switching points from ±95 G to ±925 G as the angle is varied from 0° to 90° at 300 K. The observed shifts in switching points become more pronounced (±165 G to ±1450 G) at 4.2 K for similar orientation. A monotonic increase in MR ratio is observed as the angle of magnetic field is varied in the vertical direction at 300 K and 4.2 K temperatures. This variation of B (from 0° to 90°) increases the magnitude of MR ratio from ∼0.08% to ∼0.14% at 300 K, while at 4.2 K it progresses to ∼0.39% from ∼0.14%. The sensitivity related to angular variation of such spin valve structure can be employed for angle sensing applications.

  1. A Viewpoint on the Quantity "Plane Angle"

    Science.gov (United States)

    Eder, W. E.

    1982-01-01

    Properties of the quantity "plane angle" are explored under the hypothesis that it is a dimensional quantity. The exploration proceeds especially with respect to the physical concept, its mathematical treatment, vector concepts, measurement theory, units of related quantities, engineering pragmatism, and SI. An attempt is made to bring these different relations into a rational, logical and consistent framework, and thus to justify the hypothesis. Various types of vectorial quantities are recognized, and their properties described with an outline of the necessary algebraic manipulations. The concept of plane angle is amplified, and its interdependence with the circular arc is explored. The resulting units of plane angle form a class of similar scales of measurement. Consequences of the confirmed hypothesis are developed for mathematical expressions involving trigonometric functions, rotational volumes and areas, mathematical limits, differentiation and series expansion. Consequences for mechanical rotational quantities are developed, with proposals for revisions to a number of expressions for derived units within SI. A revised definition for the quantity "plane angle" is stated to take account of the developed insights. There is a clear need to reconsider the status of plane angle and some other quantities within the international framework of SI.

  2. PRIMARY OPEN ANGLE GLAUCOMA IN THYROID DISORDER

    Directory of Open Access Journals (Sweden)

    Pragati Garg

    2016-07-01

    Full Text Available PURPOSE To assess the association of thyroid profile with open angle glaucoma. DESIGN Cross-sectional observational study. MATERIAL AND METHOD 128 cases of diagnosed thyroid disorder were enrolled. 5 cases dropped out. Ocular examination included applanation tonometry, stereoscopic optic disc photography, and automated perimetry. Correlative association of thyroid disorder and open angle glaucoma was assessed. RESULTS Of 123 patients of thyroid disorder, 87.8% had hypothyroidism and remaining 12.2% had hyperthyroidism. 15.74% of hypothyroidism and 20% of hyperthyroidism patients had open angle glaucoma, which was statistically significant (Pearson chi-square: Value=6.548, df=2, p=0.040. On multivariate analysis with other risk factors like female sex, family history of glaucoma, myopia, hypertension, and diabetes; it was found that hypothyroidism is an independent risk factor for open angle glaucoma. CONCLUSION All patients having thyroid disorder should be investigated for early diagnosis of open angle glaucoma so that if need be antiglaucoma treatment is started at the earliest and the eye maybe saved from any further deterioration.

  3. 7 CFR 29.3037 - Length.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Length. 29.3037 Section 29.3037 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing.... Length, as an element of quality, does not apply to tobacco in strip form. (See Elements of quality.) [24...

  4. 7 CFR 29.6024 - Length.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Length. 29.6024 Section 29.6024 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Standards Definitions § 29.6024 Length. The linear measurement of cured tobacco leaves from the...

  5. Local gauge invariant QED with fundamental length

    International Nuclear Information System (INIS)

    Kadyshevsky, V.G.; Mateev, M.D.

    1981-01-01

    A local gauge theory of electromagnetic interactions with the fundamental length l as a new universal scale is worked out. The Lagrangian contains new extra terms in which the coupling constant is proportional to the fundamental length. The theory has an elegant geometrical basis: in momentum representation one faces de Sitter momentum space with curvature radius 1/l [ru

  6. Analysis of ureteral length in adult cadavers

    Directory of Open Access Journals (Sweden)

    Hugo F. F. Novaes

    2013-04-01

    Full Text Available Introduction In some occasions, correlations between human structures can help planning surgical intra-abdominal interventions. The previous determination of ureteral length helps pre-operatory planning of surgeries, reduces costs of auxiliary exams, the correct choice of double-J catheter with low morbidity and fewer symptoms, and an adequate adhesion to treatment. Objective To evaluate ureteral length in adult cadavers and to analyze its correlation with anthropometric measures. Materials and Methods: From April 2009 to January 2012 we determined ureteral length of adult cadavers submitted to necropsy and obtained the following measures: height, distance from shoulder to wrist, elbow-wrist, xiphoid appendix-umbilicus, umbilicus-pubis, xiphoid appendix-pubis and between iliac spines. We analyzed the correlations between ureteral length and those anthropometric measures. Results We dissected 115 ureters from 115 adult corpses from April 2009 to January 2012. Median ureteral length didn't vary between sexes or according to height. It was observed no correlation among ureteral length and all considered anthropometric measures in all analyzed subgroups and in general population. There were no significant differences between right and left ureteral measures. Conclusions There is no difference of ureteral length in relation to height or gender (male or female. There is no significant correlation among ureteral length and the considered anthropometric measures.

  7. The length of the male urethra

    Directory of Open Access Journals (Sweden)

    Tobias. S. Kohler

    2008-08-01

    Full Text Available PURPOSE: Catheter-based medical devices are an important component of the urologic armamentarium. To our knowledge, there is no population-based data regarding normal male urethral length. We evaluated the length of the urethra in men with normal genitourinary anatomy undergoing either Foley catheter removal or standard cystoscopy. MATERIALS AND METHODS: Male urethral length was obtained in 109 men. After study permission was obtained, the subject's penis was placed on a gentle stretch and the catheter was marked at the tip of the penis. The catheter was then removed and the distance from the mark to the beginning of the re-inflated balloon was measured. Alternatively, urethral length was measured at the time of cystoscopy, on removal of the cystoscope. Data on age, weight, and height was obtained in patients when possible. RESULTS: The mean urethral length was 22.3 cm with a standard deviation of 2.4 cm. Urethral length varied between 15 cm and 29 cm. No statistically significant correlation was found between urethral length and height, weight, body mass index (BMI, or age. CONCLUSIONS: Literature documenting the length of the normal male adult urethra is scarce. Our data adds to basic anatomic information of the male urethra and may be used to optimize genitourinary device design.

  8. On the homology length spectrum of surfaces

    OpenAIRE

    Massart, Daniel; Parlier, Hugo

    2014-01-01

    On a surface with a Finsler metric, we investigate the asymptotic growth of the number of closed geodesics of length less than L which minimize length among all geodesic multicurves in the same homology class. An important class of surfaces which are of interest to us are hyperbolic surfaces.

  9. Paternal age and telomere length in twins

    DEFF Research Database (Denmark)

    Hjelmborg, Jacob B; Dalgård, Christine; Mangino, Massimo

    2015-01-01

    Telomere length, a highly heritable trait, is longer in offspring of older fathers. This perplexing feature has been attributed to the longer telomeres in sperm of older men and it might be an 'epigenetic' mechanism through which paternal age plays a role in telomere length regulation in humans...

  10. Influence of mandibular length on mouth opening

    NARCIS (Netherlands)

    Dijkstra, PU; Hof, AL; Stegenga, B; De Bont, LGM

    Theoretically, mouth opening not only reflects the mobility of the temporomandibular joints (TMJs) but also the mandibular length. Clinically, the exact relationship between mouth opening, mandibular length, and mobility of TMJs is unclear. To study this relationship 91 healthy subjects, 59 women

  11. New Very Small Angle Neutron Scattering (VSANS) Instrument

    International Nuclear Information System (INIS)

    Van Every, E; Kulesza, J; Deyhim, A

    2016-01-01

    The design of a new Very Small Angle Neutron Scattering (VSANS) Instrument for use in National Institute of Standards And Technology (NIST) will be discussed. This instrument is similar to a shorter instrument we designed and delivered to ANSTO in Australia called the Bilby SANS instrument. The NIST VSANS and the ANSTO Bilby SANS instruments have very similar dimensions for length and diameter and have similar requirements for internal detector motion, top access port, walkway supports, and ports; however, the Bilby SANS instrument vacuum requirement was lower (7.5×10-5 Torr) and the entire (60,000 pound) vessel was required to move 1.5 meters on external rails with a repeatability of 100 um, which ADC achieved. The NIST VSANS length is 24 meter, internal diameter 2.3 meter with three internal carriages. The NIST VSANS instrument, which covers the usual SANS range will also allow configuration to cover the range between q ∼| 10 -4 A -1 to 10 -3 A -1 with a sample beam current of (10 4 neutrons/s). The key requirements are a second position-sensitive detector system having a 1 mm pixel size and a longer sample-detector flight path of 20 m (i.e., a 40 m instrument). (paper)

  12. Small-angle neutron scattering study of natural aquatic nanocolloids.

    Science.gov (United States)

    Jarvie, Helen P; King, Stephen M

    2007-04-15

    We examine the potential of small-angle neutron scattering (SANS) as a quantitative tool for studying nanostructure and length scales in natural freshwater aquatic colloidal dispersions (river water, river bed sediments, agricultural field drainage and slurry). Our results show that natural aquatic colloids are generally fractal with 3D network-type structures. None of these structures are consistent with diffusion-limited (DLCA) or reaction-limited (RLCA) particleparticle aggregation processes. The results also suggest three characteristic length scales: one ca. 3-10 nm, which we identify with "primary particle" sizes, another of ca. 20-50 nm suggestive of small aggregates, and the last ca. 50-200 nm which we postulate arises from transient networks of the aggregates. The role of organic matter in mediating colloid structure in aquatic dispersions was examined by neutron contrast variation and by measuring samples both before and after treatment with hydrogen peroxide. The results suggest that the aggregate network structure is mediated by organic matter.

  13. Sex of college students moderates associations among bedtime, time in bed, and circadian phase angle.

    Science.gov (United States)

    Van Reen, Eliza; Sharkey, Katherine M; Roane, Brandy M; Barker, David; Seifer, Ronald; Raffray, Tifenn; Bond, Tamara L; Carskadon, Mary A

    2013-12-01

    Sex differences in circadian rhythms have been reported with some conflicting results. The timing of sleep and length of time in bed have not been considered, however, in previous such studies. The current study has 3 major aims: (1) replicate previous studies in a large sample of young adults for sex differences in sleep patterns and dim light melatonin onset (DLMO) phase; (2) in a subsample constrained by matching across sex for bedtime and time in bed, confirm sex differences in DLMO and phase angle of DLMO to bedtime; (3) explore sex differences in the influence of sleep timing and length of time in bed on phase angle. A total of 356 first-year Brown University students (207 women) aged 17.7 to 21.4 years (mean = 18.8 years, SD = 0.4 years) were included in these analyses. Wake time was the only sleep variable that showed a sex difference. DLMO phase was earlier in women than men and phase angle wider in women than men. Shorter time in bed was associated with wider phase angle in women and men. In men, however, a 3-way interaction indicated that phase angles were influenced by both bedtime and time in bed; a complex interaction was not found for women. These analyses in a large sample of young adults on self-selected schedules confirm a sex difference in wake time, circadian phase, and the association between circadian phase and reported bedtime. A complex interaction with length of time in bed occurred for men but not women. We propose that these sex differences likely indicate fundamental differences in the biology of the sleep and circadian timing systems as well as in behavioral choices.

  14. Modelling small-angle scattering data from complex protein-lipid systems

    DEFF Research Database (Denmark)

    Kynde, Søren Andreas Røssell

    the techniques very well suited for the study of the nanodisc system. Chapter 3 explains two different modelling approaches that can be used in the analysis of small-angle scattering data from lipid-protein complexes. These are the continuous approach where the system of interest is modelled as a few regular...... are particularly interesting to study because they are common targets for pharmaceutical drugs. At the same time they are unfortunately unstable in solution which make them challenging to study. Phospholipid nanodiscs are small patches of lipid membrane stabilised by a belt of amphipathic helices. They can act...... as carriers of membrane proteins. Together they form monodisperse soluble aggregates of about 10 nm in size. Chapter 2 introduces the method of small-angle scattering. Small-angle X-ray and neutron scattering are well suited for studying particles in solution on length scales from 1 to 100 nm. This makes...

  15. Economic issues of broiler production length

    Directory of Open Access Journals (Sweden)

    Szőllősi László

    2014-01-01

    Full Text Available The length of broiler production cycle is also an important factor when profitability is measured. This paper is to determine the effects of different market ages and down-time period, overall broiler production cycle length on performance and economic parameters based on Hungarian production and financial circumstances. A deterministic model was constructed to manage the function-like correlations of age-related daily weight gain, daily feed intake and daily mortality data. The results show that broiler production cycle length has a significant effect on production and economic performance. Cycle length is determined by the length of down-time and grow-out periods. If down-time period is reduced by one day, an average net income of EUR 0.55 per m2 is realizable. However, the production period is not directly proportional either with emerging costs or obtainable revenues. Profit maximization is attainable if the production period is 41-42 days.

  16. Screening length in dusty plasma crystals

    International Nuclear Information System (INIS)

    Nikolaev, V S; Timofeev, A V

    2016-01-01

    Particles interaction and value of the screening length in dusty plasma systems are of great interest in dusty plasma area. Three inter-particle potentials (Debye potential, Gurevich potential and interaction potential in the weakly collisional regime) are used to solve equilibrium equations for two dusty particles suspended in a parabolic trap. The inter-particle distance dependence on screening length, trap parameter and particle charge is obtained. The functional form of inter-particle distance dependence on ion temperature is investigated and compared with experimental data at 200-300 K in order to test used potentials applicability to dusty plasma systems at room temperatures. The preference is given to the Yukawa-type potential including effective values of particle charge and screening length. The estimated effective value of the screening length is 5-15 times larger than the Debye length. (paper)

  17. Copoly(Imide Siloxane) Abhesive Materials with Varied Siloxane Oligomer Length

    Science.gov (United States)

    Wohl, Christopher J.; Atkins, Brad M.; Belcher, Marcus A.; Connell, John W.

    2010-01-01

    Incorporation of PDMS moieties into a polyimide matrix lowered the surface energy resulting in enhanced adhesive interactions. Polyimide siloxane materials were generated using amine-terminated PDMS oligomers of different lengths to study changes in surface migration behavior, phase segregation, mechanical, thermal, and optical properties. These materials were characterized using contact angle goniometry, tensile testing, and differential scanning calorimetry. The surface migration behavior of the PDMS component depended upon the siloxane molecular weight as indicated by distinct relationships between PDMS chain length and advancing water contact angles. Similar correlations were observed for percent elongation values obtained from tensile testing, while the addition of PDMS reduced the modulus. High fidelity topographical modification via laser ablation patterning further reduced the polyimide siloxane surface energy. Initial particulate adhesion testing experiments demonstrated that polyimide siloxane materials exhibited greater abhesive interactions relative to their respective homopolyimides.

  18. Small angle neutron scattering investigations of spin disorder in nanocomposite soft magnets

    International Nuclear Information System (INIS)

    Vecchini, C.; Moze, O.; Suzuki, K.; Cadogan, J.M.; Pranzas, K.; Michels, A.; Weissmueller, J.

    2006-01-01

    The technique of SANS (small angle neutron scattering) furnishes unique information on the characteristic magnetic length scales and local magnetic anisotropies at the nanoscale in nanocomposite ferromagnets. Such information is not presently available using any other microscopic technique. The basic principles and results of the technique will be presented with regard to a unique and unexpected observation of a dipole field controlled spin disorder in a prototypical soft nanocomposite ferromagnet of the Nanoperm type

  19. Angle-averaged Compton cross sections

    Energy Technology Data Exchange (ETDEWEB)

    Nickel, G.H.

    1983-01-01

    The scattering of a photon by an individual free electron is characterized by six quantities: ..cap alpha.. = initial photon energy in units of m/sub 0/c/sup 2/; ..cap alpha../sub s/ = scattered photon energy in units of m/sub 0/c/sup 2/; ..beta.. = initial electron velocity in units of c; phi = angle between photon direction and electron direction in the laboratory frame (LF); theta = polar angle change due to Compton scattering, measured in the electron rest frame (ERF); and tau = azimuthal angle change in the ERF. We present an analytic expression for the average of the Compton cross section over phi, theta, and tau. The lowest order approximation to this equation is reasonably accurate for photons and electrons with energies of many keV.

  20. Angle-averaged Compton cross sections

    International Nuclear Information System (INIS)

    Nickel, G.H.

    1983-01-01

    The scattering of a photon by an individual free electron is characterized by six quantities: α = initial photon energy in units of m 0 c 2 ; α/sub s/ = scattered photon energy in units of m 0 c 2 ; β = initial electron velocity in units of c; phi = angle between photon direction and electron direction in the laboratory frame (LF); theta = polar angle change due to Compton scattering, measured in the electron rest frame (ERF); and tau = azimuthal angle change in the ERF. We present an analytic expression for the average of the Compton cross section over phi, theta, and tau. The lowest order approximation to this equation is reasonably accurate for photons and electrons with energies of many keV

  1. Precision measurements of the CKM angle gamma

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    The level of CP-violation permitted within the Standard Model cannot account for the matter dominated universe in which we live. Within the Standard Model the CKM matrix, which describes the quark couplings, is expected to be unitary. By making precise measurements of the CKM matrix parameters new physics models can be constrained, or with sufficient precision the effects of physics beyond the standard model might become apparent. The CKM angle gamma is the least well known angle of the unitarity triangle. It is the only angle easily accessible at tree-level, and furthermore has almost no theoretical uncertainties. Therefore it provides an invaluable Standard Model benchmark against which other new physics sensitive tests of the CP-violation can be made. I will discuss recent measurements of gamma using the the Run 1 LHCb dataset, which improve our knowledge of this key parameter.

  2. Flocking and invariance of velocity angles.

    Science.gov (United States)

    Liu, Le; Huang, Lihong; Wu, Jianhong

    2016-04-01

    Motsch and Tadmor considered an extended Cucker-Smale model to investigate the flocking behavior of self-organized systems of interacting species. In this extended model, a cone of the vision was introduced so that outside the cone the influence of one agent on the other is lost and hence the corresponding influence function takes the value zero. This creates a problem to apply the Motsch-Tadmor and Cucker-Smale method to prove the flocking property of the system. Here, we examine the variation of the velocity angles between two arbitrary agents, and obtain a monotonicity property for the maximum cone of velocity angles. This monotonicity permits us to utilize existing arguments to show the flocking property of the system under consideration, when the initial velocity angles satisfy some minor technical constraints.

  3. A heterodyne interferometer for angle metrology

    International Nuclear Information System (INIS)

    Hahn, Inseob; Weilert, M.; Wang, X.; Goullioud, R.

    2010-01-01

    We have developed a compact, high-resolution, angle measurement instrument based on a heterodyne interferometer. Common-path heterodyne interferometer metrology is used to measure displacements of a reflective target surface. In the interferometer set up, an optical mask is used to sample the laser beam reflecting back from four areas on a target surface. From the relative displacement measurements of the target surface areas, we can simultaneously determine angular rotations around two orthogonal axes in a plane perpendicular to the measurement beam propagation direction. The device is used in a testbed for a tracking telescope system where pitch and yaw angle measurements of a flat mirror are performed. Angle noise measurement of the device shows 0.1 nrad/√(Hz) at 1 Hz, at a working distance of 1 m. The operation range and nonlinearity of the device when used with a flat mirror is approximately ±0.15 mrad, and 3 μrad rms, respectively.

  4. Probing the Conformational Distributions of Sub-Persistence Length DNA

    Energy Technology Data Exchange (ETDEWEB)

    Mastroianni, Alexander; Sivak, David; Geissler, Phillip; Alivisatos, Paul

    2009-06-08

    We have measured the bending elasticity of short double-stranded DNA (dsDNA) chains through small-angle X-ray scattering from solutions of dsDNA-linked dimers of gold nanoparticles. This method, which does not require exertion of external forces or binding to a substrate, reports on the equilibrium distribution of bending fluctuations, not just an average value (as in ensemble FRET) or an extreme value (as in cyclization), and in principle provides a more robust data set for assessing the suitability of theoretical models. Our experimental results for dsDNA comprising 42-94 basepairs (bp) are consistent with a simple worm-like chain model of dsDNA elasticity, whose behavior we have determined from Monte Carlo simulations that explicitly represent nanoparticles and their alkane tethers. A persistence length of 50 nm (150 bp) gave a favorable comparison, consistent with the results of single-molecule force-extension experiments on much longer dsDNA chains, but in contrast to recent suggestions of enhanced flexibility at these length scales.

  5. Positron Emission Mammography with Multiple Angle Acquisition

    Energy Technology Data Exchange (ETDEWEB)

    Mark F. Smith; Stan Majewski; Raymond R. Raylman

    2002-11-01

    Positron emission mammography (PEM) of F-18 fluorodeoxyglucose (FDG) uptake in breast tumors with dedicated detectors typically has been accomplished with two planar detectors in a fixed position with the breast under compression. The potential use of PEM imaging at two detector positions to guide stereotactic breast biopsy has motivated us to use PEM coincidence data acquired at two or more detector positions together in a single image reconstruction. Multiple angle PEM acquisition and iterative image reconstruction were investigated using point source and compressed breast phantom acquisitions with 5, 9, 12 and 15 mm diameter spheres and a simulated tumor:background activity concentration ratio of 6:1. Image reconstruction was performed with an iterative MLEM algorithm that used coincidence events between any two detector pixels on opposed detector heads at each detector position. This present study compared two acquisition protocols: 2 angle acquisition with detector angular positions of -15 and +15 degrees and 11 angle acquisition with detector positions spaced at 3 degree increments over the range -15 to +15 degrees. Three- dimensional image resolution was assessed for the point source acquisitions, and contrast and signal-to-noise metrics were evaluated for the compressed breast phantom with different simulated tumor sizes. Radial and tangential resolutions were similar for the two protocols, while normal resolution was better for the 2 angle acquisition. Analysis is complicated by the asymmetric point spread functions. Signal- to-noise vs. contrast tradeoffs were better for 11 angle acquisition for the smallest visible 9 mm sphere, while tradeoff results were mixed for the larger and more easily visible 12 mm and 15 mm diameter spheres. Additional study is needed to better understand the performance of limited angle tomography for PEM. PEM tomography experiments with complete angular sampling are planned.

  6. Positron Emission Mammography with Multiple Angle Acquisition

    Energy Technology Data Exchange (ETDEWEB)

    Mark F. Smith; Stan Majewski; Raymond R. Raylman

    2002-11-01

    Positron emission mammography (PEM) of F-18 fluorodeoxyglucose (FbG) uptake in breast tumors with dedicated detectors typically has been accomplished with two planar detectors in a fixed position with the breast under compression. The potential use of PEM imaging at two detector positions to guide stereotactic breast biopsy has motivated us to use PEM coincidence data acquired at two or more detector positions together in a single image reconstruction. Multiple angle PEM acquisition and iterative image reconstruction were investigated using point source and compressed breast phantom acquisitions with 5, 9, 12 and 15 mm diameter spheres and a simulated tumor:background activity concentration ratio of 6:1. Image reconstruction was performed with an iterative MLEM algorithm that used coincidence events between any two detector pixels on opposed detector heads at each detector position. This present study compared two acquisition protocols: 2 angle acquisition with detector angular positions of -15 and +15 degrees and 11 angle acquisition with detector positions spaced at 3 degree increments over the range -15 to +15 degrees. Three-dimensional image resolution was assessed for the point source acquisitions, and contrast and signal-to-noise metrics were evaluated for the compressed breast phantom with different simulated tumor sizes. Radial and tangential resolutions were similar for the two protocols, while normal resolution was better for the 2 angle acquisition. Analysis is complicated by the asymmetric point spread functions. Signal- to-noise vs. contrast tradeoffs were better for 11 angle acquisition for the smallest visible 9 mm sphere, while tradeoff results were mixed for the larger and more easily visible 12 mm and 15 mm diameter spheres. Additional study is needed to better understand the performance of limited angle tomography for PEM. PEM tomography experiments with complete angular sampling are planned.

  7. Neutron focusing optics for low-resolution small-angle scattering

    International Nuclear Information System (INIS)

    Mildner, D.F.R.

    1994-01-01

    Small-angle neutron scattering instruments use large source and sample areas with long flight paths to obtain the necessary resolution. Increased count rates may be obtained using collimators that converge to a point on the detector. Further increases may be obtained by converging guides in the form of a focusing lens. A low-resolution small-angle scattering instrument that uses converging capillary fibers as a focusing lens is proposed. Such a device requires the use of a detector that has a fine spatial resolution, perhaps less than 0.1 mm. Expressions are derived for the resolution and the intensity optimized for such an instrument. The relationship is determined between the guide dimensions, the focal length and the critical angle of the internal coating of the individual fiber channels. The critical angle of the focusing lens dominates the resolution, and such an instrument is useful only for low-resolution measurements. However, the greatly reduced length is only valuable if there is a high-resolution detector to match the dimensions of the guide. Despite its low resolution, such an instrument might eventually be useful for survey or characterization measurements. (orig.)

  8. Angles between Curves in Metric Measure Spaces

    Directory of Open Access Journals (Sweden)

    Han Bang-Xian

    2017-09-01

    Full Text Available The goal of the paper is to study the angle between two curves in the framework of metric (and metric measure spaces. More precisely, we give a new notion of angle between two curves in a metric space. Such a notion has a natural interplay with optimal transportation and is particularly well suited for metric measure spaces satisfying the curvature-dimension condition. Indeed one of the main results is the validity of the cosine formula on RCD*(K, N metric measure spaces. As a consequence, the new introduced notions are compatible with the corresponding classical ones for Riemannian manifolds, Ricci limit spaces and Alexandrov spaces.

  9. Transport-constrained extensions of collision and track length estimators for solutions of radiative transport problems

    International Nuclear Information System (INIS)

    Kong, Rong; Spanier, Jerome

    2013-01-01

    In this paper we develop novel extensions of collision and track length estimators for the complete space-angle solutions of radiative transport problems. We derive the relevant equations, prove that our new estimators are unbiased, and compare their performance with that of more conventional estimators. Such comparisons based on numerical solutions of simple one dimensional slab problems indicate the the potential superiority of the new estimators for a wide variety of more general transport problems

  10. Kidney Length in Normal Korean Children

    International Nuclear Information System (INIS)

    Kim, In One; Cheon, Jung Eun; Lee, Young Seok; Lee, Sun Wha; Kim, Ok Hwa; Kim, Ji Hye; Kim, Hong Dae; Sim, Jung Suk

    2010-01-01

    Renal length offers important information to detect or follow-up various renal diseases. The purpose of this study was to determine the kidney length of normal Korean children in relation to age, height, weight, body surface area (BSA), and body mass index (BMI). Children between 1 month and 15 years of age without urological abnormality were recruited. Children below 3rd percentile and over 97th percentile for height or weight were excluded. Both renal lengths were measured in the prone position three times and then averaged by experienced radiologists. The mean length and standard deviation for each age group was obtained, and regression equation was calculated between renal length and age, weight, height, BSA, and BMI, respectively. Renal length was measured in 550 children. Renal length grows rapidly until 24 month, while the growth rate is reduced thereafter. The regression equation for age is: renal length (mm) = 45.953 + 1.064 x age (month, ≤ 24 months) (R2 = 0.720) or 62.173 + 0.203 x age (months, > 24 months) (R2 = 0.711). The regression equation for height is: renal length (mm) = 24.494 + 0.457 x height (cm) (R2 = 0.894). The regression equation for weight is: renal length (mm) = 38.342 + 2.117 x weight (kg, ≤18 kg) (R2 = 0.852) or 64.498 + 0.646 x weight (kg, > 18 kg) (R2 = 0.651). The regression equation for BSA is: renal length (mm) = 31.622 + 61.363 x BSA (m2, ≤ 0.7) (R2 = 0.857) or 52.717 + 29.959 x BSA (m2, > 0.7) (R2 = 0.715). The regression equation for BMI is: renal length (mm) = 44.474 + 1.163 x BMI (R2 = 0.079). This study provides data on the normal renal length and its association with age, weight, height, BSA and BMI. The results of this study will guide the detection and follow-up of renal diseases in Korean children

  11. Small angle neutron scattering and small angle X-ray scattering ...

    Indian Academy of Sciences (India)

    Abstract. The morphology of carbon nanofoam samples comprising platinum nanopar- ticles dispersed in the matrix was characterized by small angle neutron scattering (SANS) and small angle X-ray scattering (SAXS) techniques. Results show that the structure of pores of carbon matrix exhibits a mass (pore) fractal nature ...

  12. Using Digital Technology to See Angles from Different Angles. Part 2: Openings and Turns

    Science.gov (United States)

    Host, Erin; Baynham, Emily; McMaster, Heather

    2015-01-01

    Ever wondered how to use technology to teach angles? This article follows on from an earlier article published last year, providing a range of ideas for integrating technology and concrete materials with the teaching of angle concepts. The authors also provide a comprehensive list of free online games and learning objects that can be used to teach…

  13. Long-term outcomes after acute primary angle closure of Caucasian chronic angle closure glaucoma patients.

    Science.gov (United States)

    Fea, Antonio Maria; Dallorto, Laura; Lavia, Carlo; Pignata, Giulia; Rolle, Teresa; Aung, Tin

    2017-07-19

    There is a lack of information about long-term results of chronic angle closure glaucoma following an acute primary angle closure attack in Caucasian patients. The aim of the study was to report morphological and functional long-term data of chronic angle closure eyes following a monolateral primary angle closure attack and to provide a comparison with their fellow eyes. Observational retrospective case series. Fifty-seven consecutive patients (114 eyes) underwent long-term follow-up analysis. Patients underwent ophthalmic assessment more than 5 years since the angle closure attack. Intraocular pressure, best-corrected visual acuity, angle assessment, vertical C/D ratio and standard automated perimetry were the main outcome measures. Comparisons were made between angle closure attack eyes and fellow eyes and between phakic and pseudophakic eyes. Mean follow-up time was 5.86 ± 1.19 years. A significant greater damage in the angle closure eyes compared with fellow eyes in both structural (mean C/D 0.61 ± 0.16; P APAC attack to prevent potential glaucoma damage in both APAC and fellow eye. © 2017 The Authors Clinical & Experimental Ophthalmology published by John Wiley & Sons Australia, Ltd on behalf of Royal Australian and New Zealand College of Ophthalmologists.

  14. Small angle neutron scattering and small angle X-ray scattering ...

    Indian Academy of Sciences (India)

    Solid State Physics Division, Bhabha Atomic Research Centre, Mumbai 400 085, India. *Corresponding author ... ticles dispersed in the matrix was characterized by small angle neutron scattering (SANS) and small angle X-ray ... for scattering from rough pore–mass interfaces, α > 3 and the (surface) fractal dimension Ds = 6 ...

  15. Sharper angle, higher risk? The effect of cutting angle on knee mechanics in invasion sport athletes

    NARCIS (Netherlands)

    Schreurs, Mervin J.; Benjaminse, Anne; Lemmink, Koen A. P. M.

    2017-01-01

    Introduction: Cutting is an important skill in team-sports, but unfortunately is also related to non-contact ACL injuries. The purpose was to examine knee kinetics and kinematics at different cutting angles. Material and methods: 13 males and 16 females performed cuts at different angles (45°, 90°,

  16. Small angle neutron scattering and small angle X-ray scattering ...

    Indian Academy of Sciences (India)

    2015-11-27

    Nov 27, 2015 ... Small angle neutron scattering and small angle X-ray scattering studies of platinum-loaded carbon foams. P U Sastry V K Aswal A G Wagh ... Proceedings of the International Workshop/Conference on Computational Condensed Matter Physics and Materials Science (IWCCMP-2015). Posted on November ...

  17. Angle at the Medial Border: The Spinovertebra Angle and Its Significance

    Directory of Open Access Journals (Sweden)

    G. S. Oladipo

    2015-01-01

    Full Text Available Background. The evolution from quadrupedalism to bipedalism has adjusted the balance of the upper limb to extensive movement at the shoulder. The scapular angles provide the point of attachment and control to various muscles and have been associated with the different movements of the shoulder girdle and joint. This has made the morphometric and anthropometric study of scapula a subject of extensive investigation. Aim. In the present study, the angle at the medial border was measured in the South-Southern Nigerian population and an anatomical name was ascribed to the angle. Method. The study was conducted on 173 scapulae (75 right and 98 left obtained from various Anatomy Department of South-Sothern Nigerian Universities. The angle at medial border was obtained by pinning the edge of the superior and inferior angles, the lined traced out, and the angle measured using a protractor. SPSS version 20 was used to analyse the data. t-test was used to determine mean angular difference in the sides. Result. The mean ± SD of the medial angle was observed to be 136.88 ± 7.70° (R = 138.13 ± 7.06° : L = 135.92 ± 8.05°. Statistical analysis using the Z-test for mean difference showed the medial angle was found to be higher in the right side of the scapula (mean difference of 2.214 ± 1.152°, but the observed difference was not statistically significant (P > 0.05. The above findings have adjusted the scapula from three to four angles (lateral, superior, inferior, and medial formed from four borders (lateral, superior, inferior, and superomedial and inferomedial. The medial angle because of its anatomical location was named “spinovertebral” angle, owing to its position at the scapulae spine, and located in medial proximity to the vertebra column. Conclusion. The medial angle (now referred to as the spinovertebral angle of the right side of the scapula is wider than the left. The representation of the spinovertebral angle is very important, as

  18. The effects of elbow joint angle change on the elbow flexor muscle activation in pulley with weight exercise.

    Science.gov (United States)

    Kang, Taewook; Seo, Youngjoon; Park, Jaehoon; Dong, Eunseok; Seo, Byungdo; Han, Dongwook

    2013-09-01

    [Purpose] This research investigated the effect of angular variation of flexion of the elbow joint on the muscle activation of elbow flexor muscles. [Subjects] The research subjects were 24 male college students with a dominant right hand who had no surgical or neurological disorders and gave their prior written consent to participation with full knowledge of the method and purpose of this study. [Methods] The subjects' shoulder joints stayed in the resting position, and the elbow joint was positioned at angles of 55°, 70°, and 90°. The angle between the pulley with weights and forearm stayed at 90°. Surface electromyography was used to measure muscle activities. Three measurements were made at each elbow angle, and every time the angle changed, two minutes rest was given. [Result] The muscle activities of the elbow flexors showed significant changes with change in the elbow joint angle, except for the biceps brachii activities between the angles of 55° and 70° of elbow flexion. The muscle activities of the biceps brachii and brachioradialis showed angle-related changes in the order of 55°, which showed the biggest value, followed by 70° and 90°. [Conclusion] In order to improve muscle strength of the elbow flexor using a pulley system, it seems more effective to have a 90° angle between the pulley with weights and the forearm when the muscle is stretched to a length 20% greater than its resting position.

  19. Zero-point length from string fluctuations

    International Nuclear Information System (INIS)

    Fontanini, Michele; Spallucci, Euro; Padmanabhan, T.

    2006-01-01

    One of the leading candidates for quantum gravity, viz. string theory, has the following features incorporated in it. (i) The full spacetime is higher-dimensional, with (possibly) compact extra-dimensions; (ii) there is a natural minimal length below which the concept of continuum spacetime needs to be modified by some deeper concept. On the other hand, the existence of a minimal length (zero-point length) in four-dimensional spacetime, with obvious implications as UV regulator, has been often conjectured as a natural aftermath of any correct quantum theory of gravity. We show that one can incorporate the apparently unrelated pieces of information-zero-point length, extra-dimensions, string T-duality-in a consistent framework. This is done in terms of a modified Kaluza-Klein theory that interpolates between (high-energy) string theory and (low-energy) quantum field theory. In this model, the zero-point length in four dimensions is a 'virtual memory' of the length scale of compact extra-dimensions. Such a scale turns out to be determined by T-duality inherited from the underlying fundamental string theory. From a low energy perspective short distance infinities are cutoff by a minimal length which is proportional to the square root of the string slope, i.e., α ' . Thus, we bridge the gap between the string theory domain and the low energy arena of point-particle quantum field theory

  20. Effect of radiographic technique upon prediction of tooth length in intraoral radiography.

    Science.gov (United States)

    Bhakdinaronk, A; Manson-Hing, L R

    1981-01-01

    Evaluation of the effect of radiographic technique upon the prediction of tooth lengths for all major types of teeth indicated the following: 1. The paralleling technique using the Rinn XCP film holder, the paralleling technique using the hemostat with bite block, and the bisecting-the-angle technique using the Rinn XCP film holder were the most accurate systems. 2. There were no significant differences among the three most accurate techniques. 3. The paralleling technique using a 16-inch tube-to-patient distance was more accurate than the bisecting-the-angle technique using an 8-inch tube-to-patient distance. 4. A beam-guiding film holder produced a more accurate radiographic image than the other film holders used in the study. 5. For the buccal roots of maxillary molars, the bisecting-the-angle technique using the Rinn XCP film holder produced the least mean difference between radiographic image and tooth length. 6. The accuracy of predicting the length of mandibular molar teeth from the diagnostic radiograph was not affected by radiographic technique.

  1. Surface Properties of Silane-Treated Diatomaceous Earth Coatings: Effect of Alkyl Chain Length.

    Science.gov (United States)

    Perera, Helanka J; Mortazavian, Hamid; Blum, Frank D

    2017-03-21

    Modification of diatomaceous earth (DE) was performed using alkyltrimethoxysilanes of different chain lengths (C3, C8, C12, C16, and C18), and their resultant properties were determined. The thermal properties of these alkyltrimethoxysilane-treated DE powders were probed using thermogravimetric analysis and temperature-modulated differential scanning calorimetry, and the surface/porosity was studied using nitrogen adsorption and electron microscopy. Crystallinity of the hydrocarbon tails occurred when the chain lengths were C12 or larger, and the adsorbed hydrocarbon amounts were 1.6 mg/m 2 or more. The wettability of functionalized DE-containing surfaces was studied using water contact angle measurements. At larger adsorbed amounts of 2.2 mg/m 2 or more, the treated DE formed superhydrophobic coatings (with water contact angles ≥150°) with a polyurethane binder. These coatings required a minimum of 30% particle loadings, which allowed the DE particles to dominate the surface. At loadings larger than approximately 50%, there was a decrease in the contact angles corresponding to a reduction in roughness on the surface. Samples with adsorbed amounts less than 2.2 mg/m 2 or chain lengths shorter than C12 were only hydrophobic. These results were in agreement with scanning electron microscopy and Brunauer-Emmett-Teller specific surface area and pore volume measurements.

  2. Changes in muscle force-length properties affect the early rise of force in vivo

    DEFF Research Database (Denmark)

    Blazevich, Anthony J; Cannavan, Dale; Horne, Sara

    2009-01-01

    Changes in contractile rate of force development (RFD), measured within a short time interval from contraction initiation, were measured after a period of strength training that led to increases in muscle fascicle length but no measurable change in neuromuscular activity. The relationship between....... A significant proportion of the variance in RFD measured only in the initial contraction phase (0-30 ms) could be explained by shifts in the moment-angle relation (r=-0.66-0.71; R2=0.44-0.50). Training-induced increases in muscle fascicle length may lead to a reduced or complete lack of adaptive gains...... training-induced shifts in the moment-angle relation and changes in RFD measured to 30 ms (i.e., early) and 200 ms (i.e., late) from the onset of isometric knee extension force were examined; shifts in the moment-angle relation were used as an overall measure of changes in quadriceps muscle fascicle length...

  3. Spin-echo small-angle neutron scattering study of the structure organization of the chromatin in biological cell

    NARCIS (Netherlands)

    Iashina, E.G.; Bouwman, W.G.; Duif, C.P.; Filatov, M.V.; Grigoriev, S. V.

    2017-01-01

    Spin-echo small-angle scattering (SESANS) technique is a method to measure the structure of materials from nano- to micrmeter length scales. This method could be important for studying the packaging of DNA in the eukaryotic cell. We measured the SESANS function from chicken erythrocyte nuclei

  4. Bunch Length Measurements in SPEAR3

    Energy Technology Data Exchange (ETDEWEB)

    Corbett, W.J.; Fisher, A.; Huang, X.; Safranek, J.; Sebek, J.; /SLAC; Lumpkin, A.; /Argonne; Sannibale, F.; /LBL, Berkeley; Mok, W.; /Unlisted

    2007-11-28

    A series of bunch length measurements were made in SPEAR3 for two different machine optics. In the achromatic optics the bunch length increases from the low-current value of 16.6ps rms to about 30ps at 25ma/bunch yielding an inductive impedance of -0.17{Omega}. Reducing the momentum compaction factor by a factor of {approx}60 [1] yields a low-current bunch length of {approx}4ps rms. In this paper we review the experimental setup and results.

  5. Correlation between pelvic tilt and the sacro-femoral-pubic angle in patients with adolescent idiopathic scoliosis, patients with congenital scoliosis, and healthy individuals.

    Science.gov (United States)

    Ghandhari, Hassan; Fouladi, Daniel Fadaei; Safari, Mir Bahram; Ameri, Ebrahim

    2016-02-01

    To examine whether the sacro-femoral-pubic (SFP) angle could estimate pelvic tilt (PT) in scoliotic and normal subjects. One hundred nine subjects including 38 patients with adolescent idiopathic scoliosis (AIS), 35 patients with congenital scoliosis (CS), and 36 healthy individuals were studied. PT, as the angle between the lines connecting the midpoint of the sacral plate to the centroid of one acetabulum and the vertical plane, and the SFP angle, as the angle between the midpoint of the upper sacral endplate, the centroid of one acetabulum, and the upper midpoint of the pubic symphysis, were calculated on full-length lateral and anteroposterior radiographs, respectively. Correlations between PT and the SFP angle were investigated in each group. The three groups were comparable in terms of age, sex, and the mean SFP angle. The mean PT, however, was significantly lower in healthy subjects compared to that in patients with AIS and CS. Significant and reverse correlations were present between PT and the SFP angle in all three groups (AIS: r = -0.32, p = 0.04, PT = 82.5 - average SFP angle; CS: r = -0.48, p = 0.003, PT = 95.41 - average SFP angle; healthy: r = -0.33, p = 0.04, PT = 88.95 - average SFP angle). Unlike two previous reports, the SFP angle correlated poorly to PT in this study, limiting its use as a suitable surrogate for PT in scoliotic and healthy subjects.

  6. CKM matrix exponential parametrization and Euler angles

    International Nuclear Information System (INIS)

    Dattoli, G.; Sabia, E.; Torre, A.

    1997-01-01

    They show that the exponential parametrization of the CKM matrix allows to establish exact relations between the Euler weak rotation angles and the entries of the CKM generating matrix, which has already been shown to include the hierarchy features of the Wolfenstein parametrization. The analysis includes CP-violating effects and its usefulness to treat the experimental data is also proved

  7. Gaugings at angles from orientifold reductions

    NARCIS (Netherlands)

    Roest, D.

    2009-01-01

    We consider orientifold reductions to N = 4 gauged supergravity in four dimensions. A special feature of this theory is that different factors of the gauge group can have relative angles with respect to the electro-magnetic SL(2) symmetry. These are crucial for moduli stabilization and de Sitter

  8. Experimental technique of small angle neutron scattering

    International Nuclear Information System (INIS)

    Xia Qingzhong; Chen Bo

    2006-03-01

    The main parts of Small Angle Neutron Scattering (SANS) spectrometer, and their function and different parameters are introduced from experimental aspect. Detailed information is also introduced for SANS spectrometer 'Membrana-2'. Based on practical experiments, the fundamental requirements and working condition for SANS experiments, including sample preparation, detector calibration, standard sample selection and data preliminary process are described. (authors)

  9. The resection angle in apical surgery

    DEFF Research Database (Denmark)

    von Arx, Thomas; Janner, Simone F M; Jensen, Simon S

    2016-01-01

    OBJECTIVES: The primary objective of the present radiographic study was to analyse the resection angle in apical surgery and its correlation with treatment outcome, type of treated tooth, surgical depth and level of root-end filling. MATERIALS AND METHODS: In the context of a prospective clinical...

  10. A thin film magnetoresistive angle detector

    NARCIS (Netherlands)

    Eijkel, C.J.M.; Wieberdink, Johan W.; Fluitman, J.H.J.; Popma, T.J.A.; Groot, Peter; Leeuwis, Henk

    1990-01-01

    An overview is given of the results of our research on a contactless angle detector based on the anisotropic magnetoresistance effect (AMR effect) in a permalloy thin film. The results of high-temperature annealing treatment of the pemalloy film are discussed. Such a treatment suppresses the effects

  11. A small-angle neutron scattering study

    Indian Academy of Sciences (India)

    400Da [9]. Low-angle X-ray scattering [10] and neutron scattering [11] also in- dicated serum albumin to be a prolate ellipsoid. However, studies using 1H NMR indicated that a prolate structure was unlikely; rather a heart-shaped structure was proposed [12]. The shape of albumin reveals a heart-shaped molecule that can.

  12. Solid angle subtended by two circular discs

    International Nuclear Information System (INIS)

    Gilly, Louis.

    1978-09-01

    Methods of calculation of solid angles, subtended by two circular discs are analysed. Calculus are methodically classified as follow: series development Legendre polynomes, defined integral, elliptic integrals, Bessel integrals, multiple integrals, Monte Carlo method, electrostatic analogy. Applications in Nuclear Physics are added as examples. List of numeric tables completes bibliography [fr

  13. Small Angle Light Scattering by Biological Objects

    International Nuclear Information System (INIS)

    Berdzenishvili, L.; Melikishvili, Z.

    2005-01-01

    In this paper the small angle laser radiation scattering by the particles of different shape and size is analyzed. Experimental results and theoretical calculations show that after ejection from bacteriophage DNA forms the scattering medium consisted of quasi-spherical elements with radius of R⁓10λ 0 . (author)

  14. Direct angle resolved photoemission spectroscopy and ...

    Indian Academy of Sciences (India)

    Since 1997 we systematically perform direct angle resolved photoemission spectroscopy (ARPES) on in-situ grown thin (< 30 nm) cuprate films. Specifically, we probe low-energy electronic structure and properties of high-c superconductors (HTSC) under different degrees of epitaxial (compressive vs. tensile) strain.

  15. Right-Angle Mechanized Electrical Connector

    Science.gov (United States)

    Collins, Clint A.; Blackler, David T.

    1996-01-01

    Right-angle electrical connector embedded in mechanism accommodates some initial misalignment and aligns itself. Connection and disconnection effected with relatively small forces and torques and simple movements. Actuated by one gloved hand or by robotic manipulator. Useful in underwater, nuclear, hot, cold, or toxic environments in which connections made or broken by heavily clothed technicians or by robots.

  16. A small angle neutron scattering study

    Indian Academy of Sciences (India)

    Nanocrystalline nickel oxide powders were calcined at 300, 600 and 900°C and pore structure evolution was followed by small angle neutron scattering (SANS). Pore size distributions at two widely separated size ranges have been revealed. Shrinkage of larger-sized pore with reduction in polydispersity has been observed ...

  17. SANS-1: Small angle neutron scattering

    Directory of Open Access Journals (Sweden)

    André Heinemann

    2015-08-01

    Full Text Available The new small angle scattering instrument SANS-1, jointly operated by the Technische Universität München and GEMS, Helmholtz-Zentrum Geesthacht, has completed commissioning and is in regular user service (Gilles et al., 2006. SANS-1 is located at the end of neutron guide NL4a in the Neutron Guide Hall West.

  18. SANS-1: Small angle neutron scattering

    OpenAIRE

    Heinemann, André; Mühlbauer, Sebastian

    2015-01-01

    The new small angle scattering instrument SANS-1, jointly operated by the Technische Universität München and GEMS, Helmholtz-Zentrum Geesthacht, has completed commissioning and is in regular user service (Gilles et al., 2006). SANS-1 is located at the end of neutron guide NL4a in the Neutron Guide Hall West.

  19. Camber Angle Inspection for Vehicle Wheel Alignments.

    Science.gov (United States)

    Young, Jieh-Shian; Hsu, Hong-Yi; Chuang, Chih-Yuan

    2017-02-03

    This paper introduces an alternative approach to the camber angle measurement for vehicle wheel alignment. Instead of current commercial approaches that apply computation vision techniques, this study aims at realizing a micro-control-unit (MCU)-based camber inspection system with a 3-axis accelerometer. We analyze the precision of the inspection system for the axis misalignments of the accelerometer. The results show that the axes of the accelerometer can be aligned to the axes of the camber inspection system imperfectly. The calibrations that can amend these axis misalignments between the camber inspection system and the accelerometer are also originally proposed since misalignments will usually happen in fabrications of the inspection systems. During camber angle measurements, the x -axis or z -axis of the camber inspection system and the wheel need not be perfectly aligned in the proposed approach. We accomplished two typical authentic camber angle measurements. The results show that the proposed approach is applicable with a precision of ± 0.015 ∘ and therefore facilitates the camber measurement process without downgrading the precision by employing an appropriate 3-axis accelerometer. In addition, the measured results of camber angles can be transmitted via the medium such as RS232, Bluetooth, and Wi-Fi.

  20. Camber Angle Inspection for Vehicle Wheel Alignments

    Directory of Open Access Journals (Sweden)

    Jieh-Shian Young

    2017-02-01

    Full Text Available This paper introduces an alternative approach to the camber angle measurement for vehicle wheel alignment. Instead of current commercial approaches that apply computation vision techniques, this study aims at realizing a micro-control-unit (MCU-based camber inspection system with a 3-axis accelerometer. We analyze the precision of the inspection system for the axis misalignments of the accelerometer. The results show that the axes of the accelerometer can be aligned to the axes of the camber inspection system imperfectly. The calibrations that can amend these axis misalignments between the camber inspection system and the accelerometer are also originally proposed since misalignments will usually happen in fabrications of the inspection systems. During camber angle measurements, the x-axis or z-axis of the camber inspection system and the wheel need not be perfectly aligned in the proposed approach. We accomplished two typical authentic camber angle measurements. The results show that the proposed approach is applicable with a precision of ± 0.015 ∘ and therefore facilitates the camber measurement process without downgrading the precision by employing an appropriate 3-axis accelerometer. In addition, the measured results of camber angles can be transmitted via the medium such as RS232, Bluetooth, and Wi-Fi.

  1. A small-angle neutron scattering investigation

    Indian Academy of Sciences (India)

    Hence, the steel is used in aircraft, nuclear reactor, petrochemical plants and many other industries. However, presence of carbide formers such as Mo and Cr war- rants the possibility of carbide precipitates in the structure and in turn affects the mechanical properties. Small-angle neutron scattering (SANS) is an important ...

  2. Contact angle measurement with a smartphone

    Science.gov (United States)

    Chen, H.; Muros-Cobos, Jesus L.; Amirfazli, A.

    2018-03-01

    In this study, a smartphone-based contact angle measurement instrument was developed. Compared with the traditional measurement instruments, this instrument has the advantage of simplicity, compact size, and portability. An automatic contact point detection algorithm was developed to allow the instrument to correctly detect the drop contact points. Two different contact angle calculation methods, Young-Laplace and polynomial fitting methods, were implemented in this instrument. The performance of this instrument was tested first with ideal synthetic drop profiles. It was shown that the accuracy of the new system with ideal synthetic drop profiles can reach 0.01% with both Young-Laplace and polynomial fitting methods. Conducting experiments to measure both static and dynamic (advancing and receding) contact angles with the developed instrument, we found that the smartphone-based instrument can provide accurate and practical measurement results as the traditional commercial instruments. The successful demonstration of use of a smartphone (mobile phone) to conduct contact angle measurement is a significant advancement in the field as it breaks the dominate mold of use of a computer and a bench bound setup for such systems since their appearance in 1980s.

  3. Measurement of the angle alpha at BABAR

    International Nuclear Information System (INIS)

    Perez, A.

    2009-01-01

    The authors present recent measurements of the CKM angle α using data collected by the BABAR detector at the PEP-II asymmetric-energy e + e - collider at the SLAC National Accelerator Laboratory, operating at the Υ(4S) resonance. They present constraints on α from B → ππ, B → ρρ and B → ρπ decays.

  4. Evaluation of protein dihedral angle prediction methods.

    Directory of Open Access Journals (Sweden)

    Harinder Singh

    Full Text Available Tertiary structure prediction of a protein from its amino acid sequence is one of the major challenges in the field of bioinformatics. Hierarchical approach is one of the persuasive techniques used for predicting protein tertiary structure, especially in the absence of homologous protein structures. In hierarchical approach, intermediate states are predicted like secondary structure, dihedral angles, Cα-Cα distance bounds, etc. These intermediate states are used to restraint the protein backbone and assist its correct folding. In the recent years, several methods have been developed for predicting dihedral angles of a protein, but it is difficult to conclude which method is better than others. In this study, we benchmarked the performance of dihedral prediction methods ANGLOR and SPINE X on various datasets, including independent datasets. TANGLE dihedral prediction method was not benchmarked (due to unavailability of its standalone and was compared with SPINE X and ANGLOR on only ANGLOR dataset on which TANGLE has reported its results. It was observed that SPINE X performed better than ANGLOR and TANGLE, especially in case of prediction of dihedral angles of glycine and proline residues. The analysis suggested that angle shifting was the foremost reason of better performance of SPINE X. We further evaluated the performance of the methods on independent ccPDB30 dataset and observed that SPINE X performed better than ANGLOR.

  5. Measurement of critical angle in SSTDs

    International Nuclear Information System (INIS)

    Marques, A.; Serra, D.A.B.

    1984-01-01

    A method of measurement of critical angles of etching is described, relying upon the distortion caused in the shape of the distribution in the number of etched tracks of ions emitted from a 'point-like' source. The method is applied to quartz and mica samples. (author)

  6. Contact angle measurement with a smartphone.

    Science.gov (United States)

    Chen, H; Muros-Cobos, Jesus L; Amirfazli, A

    2018-03-01

    In this study, a smartphone-based contact angle measurement instrument was developed. Compared with the traditional measurement instruments, this instrument has the advantage of simplicity, compact size, and portability. An automatic contact point detection algorithm was developed to allow the instrument to correctly detect the drop contact points. Two different contact angle calculation methods, Young-Laplace and polynomial fitting methods, were implemented in this instrument. The performance of this instrument was tested first with ideal synthetic drop profiles. It was shown that the accuracy of the new system with ideal synthetic drop profiles can reach 0.01% with both Young-Laplace and polynomial fitting methods. Conducting experiments to measure both static and dynamic (advancing and receding) contact angles with the developed instrument, we found that the smartphone-based instrument can provide accurate and practical measurement results as the traditional commercial instruments. The successful demonstration of use of a smartphone (mobile phone) to conduct contact angle measurement is a significant advancement in the field as it breaks the dominate mold of use of a computer and a bench bound setup for such systems since their appearance in 1980s.

  7. Muscle activation and blood flow do not explain the muscle length-dependent variation in quadriceps isometric endurance

    NARCIS (Netherlands)

    Kooistra, R.D.; de Ruiter, C.J.; de Haan, A.

    2005-01-01

    We investigated the role of central activation in muscle length-dependent endurance. Central activation ratio (CAR) and rectified surface electromyogram (EMG) were studied during fatigue of isometric contractions of the knee extensors at 30 and 90° knee angles (full extension = 0°). Subjects (n = 8)

  8. Intra- and Interobserver Reliability of the Cobb Angle-Vertebral Rotation Angle-Spinous Process Angle for Adolescent Idiopathic Scoliosis.

    Science.gov (United States)

    Chan, Amanda C Y; Morrison, Devlin G; Nguyen, Duc V; Hill, Douglas L; Parent, Eric; Lou, Edmond H M

    2014-05-01

    A reliability analysis of Cobb angle, vertebral rotation (VR), and spinous process angle (SPA) measurements in adolescent idiopathic scoliosis. To determine the intra- and interobserver reliability of semi-automated digital radiograph measurements. Cobb angle measurements on posteroanterior radiographs are commonly used to determine the severity of scoliosis. Vertebral rotation helps assess scoliosis 3-dimensionally and has a role in predicting curve progression. Recent studies have shown that the spinous process angle is a useful parameter in assessing scoliosis when using ultrasound imaging. Because the reliability of SPA measurements on radiographs has yet to be determined, it is important to compare the reliability of these 3 parameters (Cobb angle, VR, and SPA) using a computer assisted semi-automated method. Sixty posteroanterior radiographs of patients with adolescent idiopathic scoliosis were obtained and measured twice by 3 observers who were blinded to their previous measurements, using an in-house developed program. Measurements were obtained using a semi-automated method to minimize variability resulting from observer reliability. The intra- and interobserver reliabilities were analyzed using intra-class correlation coefficients (ICCs) as well as Bland-Altman's bias and limits of agreement. Over 350 (intra) and 90 (inter) sets of curves with an average Cobb angle of 26° ± 9° (range, 10° to 44°) were compared for each parameter. Intra-observer reliabilities for each parameter were excellent (ICC [2,1] , .82; 1.00), with mean absolute differences under 3° between most measurements. Interobserver reliability (ICC [2,1] , .72; .95) was mostly good to excellent, with mean absolute differences ranging from 2.0° to 5.6°. Both the intra- and interobserver assessment of the Cobb, VR, and SPA from the semi-automated measurements had clinically acceptable reliability ranges and may be considered for clinical implementation. Additional studies will be

  9. Impedance of finite length resistive cylinder

    Directory of Open Access Journals (Sweden)

    S. Krinsky

    2004-11-01

    Full Text Available We determine the impedance of a cylindrical metal tube (resistor of radius a, length g, and conductivity σ attached at each end to perfect conductors of semi-infinite length. Our main interest is in the asymptotic behavior of the impedance at high frequency (k≫1/a. In the equilibrium regime, ka^{2}≪g, the impedance per unit length is accurately described by the well-known result for an infinite length tube with conductivity σ. In the transient regime, ka^{2}≫g, where the contribution of transition radiation arising from the discontinuity in conductivity is important, we derive an analytic expression for the impedance and compute the short-range wakefield. The analytic results are shown to agree with numerical evaluation of the impedance.

  10. FULL LENGTH RESEARCH ARTICLE Adamu & Babatunde (2008 ...

    African Journals Online (AJOL)

    Dr. Ahmed

    FULL LENGTH RESEARCH ARTICLE. Adamu & Babatunde (2008) SWJ:21-25. Comparative Studies On the Dying rate Migration. COMPARATIVE STUDIES ON DYEING RATE MIGRATION AND WASH FASTNESS PROPERTIES OF AZO DYES. DERIVED FROM 2-AMINOTHIAZOLE DERIVATIVES ON ACETATE FABRICS.

  11. Identification of amplified fragment length polymorphism (AFLP ...

    African Journals Online (AJOL)

    Identification of amplified fragment length polymorphism (AFLP) fragments linked to soybean mosaic virus resistance gene in Glycine soja and conversion to a sequence characterized amplified regions (SCAR) marker for rapid selection.

  12. Martian Length of Day Measurements from Rovers

    Science.gov (United States)

    Eubanks, T. M.; Bills, B.

    2012-06-01

    Changes in the Martian Length of Day (LOD) can be determined at a scientifically use level by a combination of regular (but not necessarily frequent) range and Doppler measurements from Earth and dead reckoning in a Kalman filter.

  13. Complementary DNA-amplified fragment length polymorphism ...

    African Journals Online (AJOL)

    Complementary DNA-amplified fragment length polymorphism (AFLP-cDNA) analysis of differential gene expression from the xerophyte Ammopiptanthus mongolicus in response to cold, drought and cold together with drought.

  14. Relationship between morphological and amplified fragment length ...

    African Journals Online (AJOL)

    Relationship between morphological and amplified fragment length polymorphism (AFLP) marker based genetic distance with heterosis in hot pepper (Capsicum annuum L.) SL Krishnamurthy, A Mohan Rao, K Madhavi Reddy, S Ramesh, Shailaja Hittalmani, Rao M. Gopinath ...

  15. Chord length distribution for a compound capsule

    International Nuclear Information System (INIS)

    Pitřík, Pavel

    2017-01-01

    Chord length distribution is a factor important in the calculation of ionisation chamber responses. This article describes Monte Carlo calculations of the chord length distribution for a non-convex compound capsule. A Monte Carlo code was set up for generation of random chords and calculation of their lengths based on the input number of generations and cavity dimensions. The code was written in JavaScript and can be executed in the majority of HTML viewers. The plot of occurrence of cords of different lengths has 3 peaks. It was found that the compound capsule cavity cannot be simply replaced with a spherical cavity of a triangular design. Furthermore, the compound capsule cavity is directionally dependent, which must be taken into account in calculations involving non-isotropic fields of primary particles in the beam, unless equilibrium of the secondary charged particles is attained. (orig.)

  16. Mixing lengths scaling in a gravity flow

    Energy Technology Data Exchange (ETDEWEB)

    Ecke, Robert E [Los Alamos National Laboratory; Rivera, Micheal [Los Alamos National Laboratory; Chen, Jun [Los Alamos National Laboratory; Ecke, Robert E [Los Alamos National Laboratory

    2009-01-01

    We present an experimental study of the mixing processes in a gravity current. The turbulent transport of momentum and buoyancy can be described in a very direct and compact form by a Prandtl mixing length model [1]: the turbulent vertical fluxes of momentum and buoyancy are found to scale quadraticatly with the vertical mean gradients of velocity and density. The scaling coefficient is the square of the mixing length, approximately constant over the mixing zone of the stratified shear layer. We show in this paper how, in different flow configurations, this length can be related to the shear length of the flow {radical}({var_epsilon}/{partial_derivative}{sub z}u{sup 3}).

  17. CPS Trawl Life History Length Frequency Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Length distribution of a subset of individuals from a species (mainly non-target) caught during SWFSC-FRD fishery independent trawl surveys of coastal pelagic...

  18. Anatomic predictors for anterior chamber angle opening after laser peripheral iridotomy in narrow angle eyes.

    Science.gov (United States)

    Huang, Guofu; Gonzalez, Eduardo; Lee, Roland; Osmonavic, Senad; Leeungurasatien, Thidarat; He, Mingguang; Lin, Shan C

    2012-07-01

    To investigate anterior chamber parameters and biometric factors associated with degree of angle opening after laser peripheral iridotomy (LPI) for narrow angles. In this prospective cohort study, patients with narrow angles who were scheduled for LPI were recruited. Anterior chamber parameters by anterior segment coherence tomography (ASOCT) under dark conditions were compared before and after LPI. Only the right eye was used for analysis if both eyes were eligible. Measurements performed by customized software included anterior chamber depth, iris area, angle opening distance at 500 µm (AOD500) anterior to the scleral spur, iris thickness at 750 µm from sclera spur (IT750), trabecular-iris space area 500 (TISA500), and iris curvature (I-Curv). Univariate and multiple regression analyses were performed to determine the predictive factors of angle opening after LPI. Eighty-one patients with narrow angles were prospectively recruited in this study. The AOD500 increased significantly from 0.128 ± 0.081 mm (before) to 0.209 ± 0.087 mm (after) in the nasal quadrant, and from 0.103 ± 0.067 mm (before) to 0.197 ± 0.071 mm (after) in the temporal quadrant (p chamber angle widening after LPI were older age, smaller iris area, and steeper iris.

  19. Process for fabricating continuous lengths of superconductor

    Science.gov (United States)

    Kroeger, Donald M.; List, III, Frederick A.

    1998-01-01

    A process for manufacturing a superconductor. The process is accomplished by depositing a superconductor precursor powder on a continuous length of a first substrate ribbon, overlaying a continuous length of a second substrate ribbon on said first substrate ribbon, and applying sufficient pressure to form a bound layered superconductor precursor between said first substrate ribbon and said second substrates ribbon. The layered superconductor precursor is then heat treated to form a super conductor layer.

  20. Length and coverage of inhibitory decision rules

    KAUST Repository

    Alsolami, Fawaz

    2012-01-01

    Authors present algorithms for optimization of inhibitory rules relative to the length and coverage. Inhibitory rules have a relation "attribute ≠ value" on the right-hand side. The considered algorithms are based on extensions of dynamic programming. Paper contains also comparison of length and coverage of inhibitory rules constructed by a greedy algorithm and by the dynamic programming algorithm. © 2012 Springer-Verlag.

  1. Derived length for arbitrary topological spaces

    Directory of Open Access Journals (Sweden)

    A. J. Jayanthan

    1992-01-01

    Full Text Available The notion of derived length is as old as that of ordinal numbers itself. It is also known as the Cantor-Bendixon length. It is defined only for dispersed (that is scattered spaces. In this paper this notion has been extended in a natural way for all topological spaces such that all its pleasing properties are retained. In this process we solve a problem posed by V. Kannan. ([1] Page 158.

  2. The SME gauge sector with minimum length

    Energy Technology Data Exchange (ETDEWEB)

    Belich, H.; Louzada, H.L.C. [Universidade Federal do Espirito Santo, Departamento de Fisica e Quimica, Vitoria, ES (Brazil)

    2017-12-15

    We study the gauge sector of the Standard Model Extension (SME) with the Lorentz covariant deformed Heisenberg algebra associated to the minimum length. In order to find and estimate corrections, we clarify whether the violation of Lorentz symmetry and the existence of a minimum length are independent phenomena or are, in some way, related. With this goal, we analyze the dispersion relations of this theory. (orig.)

  3. Tourism and fashion: factors affecting trip length

    OpenAIRE

    Calderón García, María Haydeé; G. Gallarza, Martina; Fayos Gardó, Teresa; O'Sullivan, P.

    2016-01-01

    Tourism and shopping are closely related, and the influence of fashion shopping on a tourist's decision to travel is especially significant. The concept of cognitive and hedonic involvement enables us to relate the importance given to shopping by consumers of fashion products and of tourism services. This research analyses whether tourist involvement in fashion shopping has an impact on the length of their stay in a destination. In addition, it examines whether trip length is conditioned by t...

  4. Knee joint angle affects EMG-force relationship in the vastus intermedius muscle.

    Science.gov (United States)

    Saito, Akira; Akima, Hiroshi

    2013-12-01

    It is not understood how the knee joint angle affects the relationship between electromyography (EMG) and force of four individual quadriceps femoris (QF) muscles. The purpose of this study was to examine the effect of the knee joint angle on the EMG-force relationship of the four individual QF muscles, particularly the vastus intermedius (VI), during isometric knee extensions. Eleven healthy men performed 20-100% of maximal voluntary contraction (MVC) at knee joint angles of 90°, 120° and 150°. Surface EMG of the four QF synergists was recorded and normalized by the root mean square during MVC. The normalized EMG of the four QF synergists at a knee joint angle of 150° was significantly lower than that at 90° and 120° (P knee joint angle of 150°. Furthermore, the neuromuscular activation of the VI was the most sensitive to change in muscle length among the four QF synergistic muscles. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Multilevel Models for the Analysis of Angle-Specific Torque Curves with Application to Master Athletes

    Directory of Open Access Journals (Sweden)

    Carvalho Humberto M.

    2015-12-01

    Full Text Available The aim of this paper was to outline a multilevel modeling approach to fit individual angle-specific torque curves describing concentric knee extension and flexion isokinetic muscular actions in Master athletes. The potential of the analytical approach to examine between individual differences across the angle-specific torque curves was illustrated including between-individuals variation due to gender differences at a higher level. Torques in concentric muscular actions of knee extension and knee extension at 60°·s-1 were considered within a range of motion between 5°and 85° (only torques “truly” isokinetic. Multilevel time series models with autoregressive covariance structures with standard multilevel models were superior fits compared with standard multilevel models for repeated measures to fit anglespecific torque curves. Third and fourth order polynomial models were the best fits to describe angle-specific torque curves of isokinetic knee flexion and extension concentric actions, respectively. The fixed exponents allow interpretations for initial acceleration, the angle at peak torque and the decrement of torque after peak torque. Also, the multilevel models were flexible to illustrate the influence of gender differences on the shape of torque throughout the range of motion and in the shape of the curves. The presented multilevel regression models may afford a general framework to examine angle-specific moment curves by isokinetic dynamometry, and add to the understanding mechanisms of strength development, particularly the force-length relationship, both related to performance and injury prevention.

  6. Micromirror with large-tilting angle using Fe-based metallic glass.

    Science.gov (United States)

    Lee, Jae-Wung; Lin, Yu-Ching; Kaushik, Neelam; Sharma, Parmanand; Makino, Akihiro; Inoue, Akihisa; Esashi, Masayoshi; Gessner, Thomas

    2011-09-01

    For enhancing the micromirror properties like tilting angle and stability during actuation, Fe-based metallic glass (MG) was applied for torsion bar material. A micromirror with mirror-plate diameter of 900 μm and torsion bar dimensions length 250 μm, width 30 μm and thickness 2.5 μm was chosen for the tilting angle tests, which were performed by permanent magnets and electromagnet setup. An extremely large tilting angle of over -270° was obtained from an activation test by permanent magnet that has approximately 0.2 T of magnetic strength. A large mechanical tilting angle of over -70° was obtained by applying approximately 1.1 mT to the mirror when 93 mAwas applied to solenoid setup. The large-tilting angle of the micromirror is due to the torsion bar, which was fabricated with Fe-based MG thin film that has large elastic strain limit, fracture toughness, and excellent magnetic property.

  7. Sex determination using facial linear dimensions and angles among Hausa population of Kano State, Nigeria

    Directory of Open Access Journals (Sweden)

    Lawan H. Adamu

    2016-12-01

    Full Text Available The aim of the study was to determine sexual dimorphism as well as to predict sex using facial linear dimensions and angles among Hausas of Kano state Nigeria. A total of 283 subjects comprising 147 males and 136 females age range 18–25 years participated. Photographs methods were used to capture the face. Independent sample t-test was used to test for sex differences in the variables. Binary logistic regression was applied to obtain a predicting equation (BLR model for sex. The predicted probabilities of BLR were analyzed using receiver operating characteristic curve. The results showed that all the facial linear dimensions showed significance sexual dimorphism except interocular distance, upper facial width, philtrum length, lower vermilion width, left and right orbital width. With regards to sex prediction, upper facial height was the single best predictor of sex with an accuracy of 76.2% and 24–33% contribution to the prediction. However, the percentage accuracy increased to 91% when six variables were pooled together in the equations. For facial angles, only nasion and aperture modified angle did not show significant gender differences. However, in the variables with significant sexual dimorphism only nasomental angle showed a significant level of sex prediction with an accuracy of 70.3%. In conclusion, sex discrimination using facial linear dimensions and angles was well established in this study. The sex of an individual of Hausa ethnic group can be determined using facial linear dimensions. Dispite sexual dimorphsm shown by facial angles, only nasomental angle was good discriminator of sex.

  8. Effect of length of thinning area on the failure behavior of carbon steel pipe containing a defect of wall thinning

    International Nuclear Information System (INIS)

    Kim, Jin Weon; Park, Chi Yong

    2003-01-01

    The present study performed pipe failure tests using 102 mm-Sch. 80 carbon steel pipe with various simulated wall thinning defects, to investigate the effect of axial length of wall thinning and internal pressure on the failure behavior of pipe thinned by flow accelerated corrosion (FAC). The tests were conducted under loading conditions of four-point bending with and without internal pressure. The results showed that a failure mode of pipe with a defect depended on the magnitude of internal pressure and axial thinning length as well as stress type and thinning depth and circumferential angle. Both load carrying capability (LCC) and deformation capability (DC) were depended on stress type in the thinning area and dimensions of thinning defect. For applying tensile stress to the thinned area, the dependence of LCC on the axial length of wall thinning was determined by circumferential thinning angle, and the DC was proportionally increased with increase in axial length of wall thinning regardless of the circumferential angle. For applying compressive stress to thinned area, however, the LCC was decreased with increase in axial length of the thinned area. Also, the effect of internal pressure on failure behavior was characterized by failure mode of thinned pipe, and it promoted crack occurrence and mitigated a local buckling of the thinned area

  9. Contact angle and contact angle hysteresis measurements using the capillary bridge technique.

    Science.gov (United States)

    Restagno, Frédéric; Poulard, Christophe; Cohen, Céline; Vagharchakian, Laurianne; Léger, Liliane

    2009-09-15

    A new experimental technique is proposed to easily measure both advancing and receding contact angles of a liquid on a solid surface, with unprecedented accuracy. The technique is based on the analysis of the evolution of a capillary bridge formed between a liquid bath and a solid surface (which needs to be spherical) when the distance between the surface and the liquid bath is slowly varied. The feasibility of the technique is demonstrated using a low-energy perfluorinated surface with two different test liquids (water and hexadecane). A detailed description of both experimental procedures and computational modeling are given, allowing one to determine contact angle values. It is shown that the origin of the high accuracy of this technique relies on the fact that the contact angles are automatically averaged over the whole periphery of the contact. This method appears to be particularly adapted to the characterization of surfaces with very low contact angle hysteresis.

  10. Introduction to small-angle scattering

    International Nuclear Information System (INIS)

    Gilbert, E.

    2003-01-01

    Full text: Small angle neutron and X-ray scattering (SANS and SAXS) are ideal tools for studying the structure of materials in the size range between 10 and 1000 Angstrom. While imaging methods such as transmission electron microscopy (TEM) also have this capability, they provide images in real space, for instance individual grains in a nanocrystalline material. SANS and SAXS, on the other hand, provide (generally) a non-destructive method yielding structural information averaged over all grains with high statistical accuracy due to averaging over the whole sample volume. The use of neutrons and X-rays is also implicitly complementary due to their sensitivity to either nuclear or electron density respectively. This provides several further advantages over real-space techniques such as isotopic sensitivity and contrast variation. In this talk, I will provide an introduction to the technique with a minimum number of equations, emphasising what structural information may be obtained from small-angle scattering

  11. Fan Stagger Angle for Dirt Rejection

    Science.gov (United States)

    Gallagher, Edward J. (Inventor); Rose, Becky E. (Inventor); Brilliant, Lisa I. (Inventor)

    2015-01-01

    A gas turbine engine includes a spool, a turbine coupled to drive the spool, a propulsor coupled to be rotated about an axis by the turbine through the spool, and a gear assembly coupled between the propulsor and the spool such that rotation of the turbine drives the propulsor at a different speed than the spool. The propulsor includes a hub and a row of propulsor blades that extend from the hub. Each of the propulsor blades has a span between a root at the hub and a tip, and a chord between a leading edge and a trailing edge. The chord forms a stagger angle alpha with the axis, and the stagger angle alpha is less than 15 deg. at a position along the propulsor blade that is within an inboard 20% of the span.

  12. The small angle diffractometer SANS at PSI

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, W. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1996-11-01

    With the start-up of SINQ an instrument for small angle neutron scattering will be operational which compares well with the world`s largest and most powerful facilities of this kind. Following the classical principle of the D11-instrument of ILL, it is equipped with state-of-the-art components as are nowadays available, including options for further upgrading. Great emphasis was laid upon providing a flexible, universal multi-user facility which guarantees a comfortable and reliable operation. In the present paper, the principle layout of the instrument is presented, and the individual components are described in detail. The paper concludes with model application of small angle scattering to a system of dilute CuCo alloys which undergo a phase separation under thermal treatment, forming spherical Co-precipitates dispersed in a Cu-rich matrix. (author) 3 figs., 1 tab., 14 refs.

  13. Didactical Design Enrichment of Angle in Geometry

    Science.gov (United States)

    Setiadi, D. R.; Suryadi, D.; Mulyana, E.

    2017-09-01

    The underlying problem of this research is the lack of student’s competencies in understanding the concept of angle in geometry as the results of the teaching and learning pattern that only to receive the topic rather than to construct the topic and has not paid attention to the learning trajectory. The purpose of this research is to develop the didactical design of angle in space learning activity. The used research method is a method of qualitative research in the form of a didactical design research through three phases of analysis i.e. didactical situation analysis, metapedadidactical analysis, and retrospective analysis, which conducted in students from 10th grade at one of private schools in Bandung. Based on the results of research and discussion, the didactical design that has been made, is capable to change student’s learning habit and quite capable to develop student’s competencies although not optimal.

  14. Exclusive Backward-Angle Omega Meson Electroproduction

    Energy Technology Data Exchange (ETDEWEB)

    Wenliang, Li [Univ. of Regina, Regina, SK (Canada)

    2017-10-01

    Exclusive meson electroproduction at different squared four-momenta of the exchanged virtual photon, Q2 , and at different four-momentum transfers, t and u, can be used to probe QCD's transition from hadronic degrees of freedom at the long distance scale to quark-gluon degrees of freedom at the short distance scale. Backward-angle meson electroproduction was previously ignored, but is anticipated to offer complimentary information to conventional forward-angle meson electroproduction studies on nucleon structure. This work is a pioneering study of backward-angle ω cross sections through the exclusive 1H(e, e'p)ω reaction using the missing mass reconstruction technique. The extracted cross sections are separated into the transverse (T), longitudinal (L), and LT, TT interference terms. The analyzed data were part of experiment E01-004 (Fπ-2), which used 2.6-5.2 GeV electron beams and HMS+SOS spectrometers in Jefferson Lab Hall C. The primary objective was to detect coincidence π in the forward-angle, where the backward-angle omega events were fortuitously detected. The experiment has central Q2 values of 1.60 and 2.45 GeV2 , at W = 2.21 GeV. There was significant coverage in phi and epsilon, which allowed separation of σT,L,LT,TT . The data set has a unique u coverage of -u ~ 0, which corresponds to -t > 4 GeV2 . The separated σT result suggest a flat ~ 1/Q1.33±1.21 dependence, whereas sigma_L seems to hold a stronger 1/Q9.43±6.28 dependence. The σL/σT ratio indicate σT dominance at Q2 = 2.45 GeV2 at the ~90% confidence level. After translating the results into the -t space of the published CLAS data, our data show evidence of a backward-angle omega electroproduction peak at both Q2 settings. Previously, this phenomenon showing both forward and backward-angle peaks was only observed in the meson

  15. The accuracy of the radiographic method in root canal length measurement

    International Nuclear Information System (INIS)

    Jo, Eun Young; Park, Chang Seo

    1998-01-01

    For the successful endodontic treatment, root canal should be cleaned thoroughly by accurate mechanical and chemical canal preparation and sealed completely with canal filling material without damaging the periapical tissues. The accuracy of the root canal length measurement is a prerequisite for the success of the endodontic treatment, and the root canal length is often determined by the standard periapical radiographs and digital tactile sense. In this study, the accuracy and the clinical usefulness of Digora, an intraoral digital imaging processor and the conventional standard radiographs were compared by measuring the length from the top of the file to the root apex. 30 single rooted premolars were invested in a uniformly sized blocks and No.25 K-file was inserted into and fixed in each canal. Each block was placed in equal distance and position to satisfy the principle of the bisecting angle and paralleling techniques and Digora system's image and standard periapical radiographs were taken. Each radiograph was examined by 3 different observers by measuring the length from top of the file to the root apex and each data was compared and analyzed. The results were as follows; 1. In the bisecting angle technique, the average difference between the Digora system and standard periapical radiograph was 0.002 mm and the standard deviation was 0.341 mm which showed no statistically significant difference between the two systems (p>0.05). Also, in the paralleling technique, the average difference between these two system was 0.007 mm and the standard deviation was 0.323 mm which showed no statistically significant difference between the two systems (p>0.05). 2. In Digora system, the average difference between the bisecting angle and paralleling technique was -0.336 mm and the standard deviation was 0.472 mm which showed a statistically significant difference between the two techniques (p 0.05). In conclusion, the determination of the root canal length by using the

  16. What's the angle: a study of the angle bisected in intraoral radiography.

    Science.gov (United States)

    Manson-Hing, L R

    1980-01-01

    Intraoral radiographs were made via the bisecting-the-angle technique on patients of different ages, sexes, and races. The tooth-film angles for various areas of the mouth were measured and found to be close to 30 degrees for all areas of the mouth except the mandibular posterior regions. The study was conducted to assist in quick positioning of the x-ray beam in difficult cases.

  17. Relationship between retinal distance and object field angles for finite schematic eyes.

    Science.gov (United States)

    Suheimat, Marwan; Zhu, Hai-Feng; Lambert, Andrew; Atchison, David A

    2016-07-01

    Retinal anatomical studies have used the Drasdo & Fowler three-refracting surface schematic eye to convert between retinal distances and object field angles. We compared its performance at this task with those of more sophisticated four-refracting surface schematic eyes. Raytracing was performed for Drasdo & Fowler, Lotmar, Navarro, Liou & Brennan, Kooijman and Atchison schematic eyes, and some of their variants. The Drasdo & Fowler eye gives a greater rate of change of object field angle with retinal distance at the retinal centre of about 5% than the other schematic eyes. This rate of change also increases much more quickly into the peripheral retina for the Drasdo & Fowler eye than for the other eyes. The reason for these differences is only that the Drasdo & Fowler eye is shorter than the other eyes. The relationship between retinal distance and visual field angle appears robust to changes in retinal radius of curvature when the retina is spherical. The retinal asphericity of Kooijman and Atchison eyes appears to play a role beyond 14 mm (~50°). Changing the length of the Drasdo & Fowler eye, to match those of the four-refracting surface schematic eyes, gives similar relationships between retinal distance and object field angle up to a retinal distance of approximately 14 mm (~50°). The relationship will change with refractive error as this is related to axial length and to retinal shape, and this should be taken into consideration for accurate conversions. For distances and angles beyond 14 mm and ~50°, retinal shape should be taken into account. © 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.

  18. Measurement of the angle alpha at BABAR

    Energy Technology Data Exchange (ETDEWEB)

    Perez, A.; /Orsay, LAL

    2009-06-25

    The authors present recent measurements of the CKM angle {alpha} using data collected by the BABAR detector at the PEP-II asymmetric-energy e{sup +}e{sup -} collider at the SLAC National Accelerator Laboratory, operating at the {Upsilon}(4S) resonance. They present constraints on {alpha} from B {yields} {pi}{pi}, B {yields} {rho}{rho} and B {yields} {rho}{pi} decays.

  19. Small-Angle Scattering on Magnetoferritin Nanoparticles

    Science.gov (United States)

    Balejčíková Petrenko, L., VI; Avdeev, MV; Garamus, VM; Almásy, L.; Kopčanský, P.

    2017-05-01

    Magnetoferritin is a synthetically prepared magnetic bio-complex, consisting of apoferritin shell and iron-based nanoparticles. Superparamagnetic behaviour, nanoscale size (about 12 nm) and biological origin allow to use magnetoferritin in various applications. In this report, we present a general overview about basic physicochemical properties of magnetoferritin, as determined by small-angle X-ray and neutron scattering experiments and some interesting references on their potential bio-applications.

  20. Neutron Reflectivity and Grazing Angle Diffraction

    OpenAIRE

    Ankner, J. F.; Majkrzak, C. F.; Satija, S. K.

    1993-01-01

    Over the last 10 years, neutron reflectivity has emerged as a powerful technique for the investigation of surface and interfacial phenomena in many different fields. In this paper, a short review of some of the work on neutron reflectivity and grazing-angle diffraction as well as a description of the current and planned neutron rcflectometers at NIST is presented. Specific examples of the characterization of magnetic, superconducting, and polymeric surfaces and interfaces are included.

  1. Neutron Reflectivity and Grazing Angle Diffraction.

    Science.gov (United States)

    Ankner, J F; Majkrzak, C F; Satija, S K

    1993-01-01

    Over the last 10 years, neutron reflectivity has emerged as a powerful technique for the investigation of surface and interfacial phenomena in many different fields. In this paper, a short review of some of the work on neutron reflectivity and grazing-angle diffraction as well as a description of the current and planned neutron rcflectometers at NIST is presented. Specific examples of the characterization of magnetic, superconducting, and polymeric surfaces and interfaces are included.

  2. Ultra small angle scattering versus diffraction

    Science.gov (United States)

    Ebrahimi, O.; Treimer, W.; Strobl, M.; Feye-Treimer, U.; Beul, N.; Jericha, E.; Seidel, S. O.

    2010-11-01

    In the case of ultra small angle (neutron or x-ray) scattering (USANS, USAXS) it may happen that structures under investigations are not fully coherently illuminated by the incident wave. Despite this fact interference effects are observed similar to SAS data. In this case the measured scattering patterns must be different interpreted. We propose a procedure to calculate and adapt such scattering patterns to experimental data.

  3. Ultra small angle scattering versus diffraction

    International Nuclear Information System (INIS)

    Ebrahimi, O; Treimer, W; Strobl, M; Feye-Treimer, U; Beul, N; Jericha, E; Seidel, S O

    2010-01-01

    In the case of ultra small angle (neutron or x-ray) scattering (USANS, USAXS) it may happen that structures under investigations are not fully coherently illuminated by the incident wave. Despite this fact interference effects are observed similar to SAS data. In this case the measured scattering patterns must be different interpreted. We propose a procedure to calculate and adapt such scattering patterns to experimental data.

  4. Resonances and backward-angle scattering

    International Nuclear Information System (INIS)

    Stokstad, R.G.

    1978-01-01

    The strong enhancement of elastic scattering at large angles observed for systems such as α + 40 Ca and recently for 12 C + 28 Si and 16 O 28 Si was interpreted in terms of entrance channel resonances having a quasi-molecular character. Alternative explanations in terms of potential scattering were also presented. An overview is given of the experimental data and their interpretations. A consistent procedure for the evaluation of the experimental data is discussed. 50 references

  5. Ultrasound Assessment of Cervical Length in Pregnancy

    Directory of Open Access Journals (Sweden)

    An-Shine Chao

    2008-09-01

    Full Text Available Cervical length in high-risk women for preterm birth has to be identified before early second trimester. Sequential evaluations lead to high predictive significance. The mean cervical length at 24 weeks is about 35 mm when measured by transvaginal ultrasound. A short cervix is defined as a cervix that is less than 25 mm and funneling, i.e. ballooning of the membranes into a dilated internal os, but with a closed external os. Factors such as short cervical length, uterine anomaly, previous cervical surgery, multiple gestation and positive fetal fibronectin results are associated with preterm delivery. Serial transvaginal ultrasound examinations during the early second trimester would provide longitudinal changes in the cervical length. The use of 17α-hydroxyprogesterone caproate and cerclage has shown to be beneficial in preventing preterm delivery. When combined with other predictors such as occiput position, parity, maternal age and body mass index, cervical length is a useful parameter for predicting the feasibility of labor induction and successful delivery.

  6. Length expectation values in quantum Regge calculus

    International Nuclear Information System (INIS)

    Khatsymovsky, V.M.

    2004-01-01

    Regge calculus configuration superspace can be embedded into a more general superspace where the length of any edge is defined ambiguously depending on the 4-tetrahedron containing the edge. Moreover, the latter superspace can be extended further so that even edge lengths in each the 4-tetrahedron are not defined, only area tensors of the 2-faces in it are. We make use of our previous result concerning quantization of the area tensor Regge calculus which gives finite expectation values for areas. Also our result is used showing that quantum measure in the Regge calculus can be uniquely fixed once we know quantum measure on (the space of the functionals on) the superspace of the theory with ambiguously defined edge lengths. We find that in this framework quantization of the usual Regge calculus is defined up to a parameter. The theory may possess nonzero (of the order of Planck scale) or zero length expectation values depending on whether this parameter is larger or smaller than a certain value. Vanishing length expectation values means that the theory is becoming continuous, here dynamically in the originally discrete framework

  7. Functional scoliosis caused by leg length discrepancy

    Science.gov (United States)

    Daniszewska, Barbara; Zolynski, Krystian

    2010-01-01

    Introduction Leg length discrepancy (LLD) causes pelvic obliquity in the frontal plane and lumbar scoliosis with convexity towards the shorter extremity. Leg length discrepancy is observed in 3-15% of the population. Unequalized lower limb length discrepancy leads to posture deformation, gait asymmetry, low back pain and discopathy. Material and methods In the years 1998-2006, 369 children, aged 5 to 17 years (209 girls, 160 boys) with LLD-related functional scoliosis were treated. An external or internal shoe lift was applied. Results Among 369 children the discrepancy of 0.5 cm was observed in 27, 1 cm in 329, 1.5 cm in 9 and 2 cm in 4 children. During the first follow-up examination, within 2 weeks, the adjustment of the spine to new static conditions was noted and correction of the curve in 316 examined children (83.7%). In 53 children (14.7%) the correction was observed later and was accompanied by slight low back pain. The time needed for real equalization of limbs was 3 to 24 months. The time needed for real equalization of the discrepancy was 11.3 months. Conclusions Leg length discrepancy equalization results in elimination of scoliosis. Leg length discrepancy < 2 cm is a static disorder; that is why measurements should be performed in a standing position using blocks of adequate thickness and the position of the posterior superior iliac spine should be estimated. PMID:22371777

  8. Pair creation at large inherent angles

    International Nuclear Information System (INIS)

    Chen, P.; Tauchi, T.; Schroeder, D.V.

    1992-01-01

    In the next-generation linear colliders, the low-energy e + e - pairs created during the collision of high-energy e + e - beams would cause potential deleterious background problems to the detectors. At low collider energies, the pairs are made essentially by the incoherent process, where the pair is created by the interaction of beamstrahlung photons on the individual particles in the oncoming beam. This problem was first identified by Zolotarev, et al. At energies where the beamstrahlung parameter Υ lies approximately in the range 0.6 approx-lt Υ approx-lt 100, pair creation from the beamstrahlung photons is dominated by a coherent process, first noted by Chen. The seriousness of this pair creation problem lies in the transverse momenta that the pair particles carry when leaving the interaction point (IP) with large angles. Since the central issue is the transverse momentum for particles with large angles, the authors notice that there is another source for it. Namely, when the pair particles are created at low energies, the intrinsic angles of these pairs when produced may already be large. In this paper they reinvestigate the problem, following essentially the same equivalent photon approach, but with changes in specific details including the virtual photon spectrum. In addition, various assumptions are made more explicit. The formulas derived are then applied to the collider parameters designed by Palmer

  9. Multi-Angle Snowflake Camera Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Stuefer, Martin [Univ. of Alaska, Fairbanks, AK (United States); Bailey, J. [Univ. of Alaska, Fairbanks, AK (United States)

    2016-07-01

    The Multi-Angle Snowflake Camera (MASC) takes 9- to 37-micron resolution stereographic photographs of free-falling hydrometers from three angles, while simultaneously measuring their fall speed. Information about hydrometeor size, shape orientation, and aspect ratio is derived from MASC photographs. The instrument consists of three commercial cameras separated by angles of 36º. Each camera field of view is aligned to have a common single focus point about 10 cm distant from the cameras. Two near-infrared emitter pairs are aligned with the camera’s field of view within a 10-angular ring and detect hydrometeor passage, with the lower emitters configured to trigger the MASC cameras. The sensitive IR motion sensors are designed to filter out slow variations in ambient light. Fall speed is derived from successive triggers along the fall path. The camera exposure times are extremely short, in the range of 1/25,000th of a second, enabling the MASC to capture snowflake sizes ranging from 30 micrometers to 3 cm.

  10. Off-Angle Iris Correction Methods

    Energy Technology Data Exchange (ETDEWEB)

    Santos-Villalobos, Hector J [ORNL; Thompson, Joseph T [ORNL; Karakaya, Mahmut [ORNL; Boehnen, Chris Bensing [ORNL

    2016-01-01

    In many real world iris recognition systems obtaining consistent frontal images is problematic do to inexperienced or uncooperative users, untrained operators, or distracting environments. As a result many collected images are unusable by modern iris matchers. In this chapter we present four methods for correcting off-angle iris images to appear frontal which makes them compatible with existing iris matchers. The methods include an affine correction, a retraced model of the human eye, measured displacements, and a genetic algorithm optimized correction. The affine correction represents a simple way to create an iris image that appears frontal but it does not account for refractive distortions of the cornea. The other method account for refraction. The retraced model simulates the optical properties of the cornea. The other two methods are data driven. The first uses optical flow to measure the displacements of the iris texture when compared to frontal images of the same subject. The second uses a genetic algorithm to learn a mapping that optimizes the Hamming Distance scores between off-angle and frontal images. In this paper we hypothesize that the biological model presented in our earlier work does not adequately account for all variations in eye anatomy and therefore the two data-driven approaches should yield better performance. Results are presented using the commercial VeriEye matcher that show that the genetic algorithm method clearly improves over prior work and makes iris recognition possible up to 50 degrees off-angle.

  11. Studies in small angle scattering techniques

    International Nuclear Information System (INIS)

    Moellenbach, K.

    1980-03-01

    Small angle scattering of neutrons, X-rays and γ-rays are found among the spectroscopic methods developed in the recent years. Although these techniques differ from each other in many respects, e.g. radiation sources and technical equipment needed, their power to resolve physical phenomena and areas of application can be discussed in a general scheme. Selected examples are given illustrating the use of specific technical methods. Jahn-Teller driven structural phase transitions in Rare Earth zircons were studied with neutron scattering as well as small angle γ-ray diffraction. The study of neutron scattering from formations of magnetic domains in the Ising ferromagnet LiTbF 4 is a second example. Both these examples represent more than experimental test cases since the theoretical interpretations of the data obtained are discussed as well. As a last example the use of small angle scattering methods for the study of molecular biological samples is discussed. In particular the experimental procedures used in connection with scattering from aqueous solutions of proteins and protein complexes are given. (Auth.)

  12. Head flexion angle while using a smartphone.

    Science.gov (United States)

    Lee, Sojeong; Kang, Hwayeong; Shin, Gwanseob

    2015-01-01

    Repetitive or prolonged head flexion posture while using a smartphone is known as one of risk factors for pain symptoms in the neck. To quantitatively assess the amount and range of head flexion of smartphone users, head forward flexion angle was measured from 18 participants when they were conducing three common smartphone tasks (text messaging, web browsing, video watching) while sitting and standing in a laboratory setting. It was found that participants maintained head flexion of 33-45° (50th percentile angle) from vertical when using the smartphone. The head flexion angle was significantly larger (p smartphone, could be a main contributing factor to the occurrence of neck pain of heavy smartphone users. Practitioner Summary: In this laboratory study, the severity of head flexion of smartphone users was quantitatively evaluated when conducting text messaging, web browsing and video watching while sitting and standing. Study results indicate that text messaging while sitting caused the largest head flexion than that of other task conditions.

  13. Environmental stresses disrupt telomere length homeostasis.

    Directory of Open Access Journals (Sweden)

    Gal Hagit Romano

    Full Text Available Telomeres protect the chromosome ends from degradation and play crucial roles in cellular aging and disease. Recent studies have additionally found a correlation between psychological stress, telomere length, and health outcome in humans. However, studies have not yet explored the causal relationship between stress and telomere length, or the molecular mechanisms underlying that relationship. Using yeast as a model organism, we show that stresses may have very different outcomes: alcohol and acetic acid elongate telomeres, whereas caffeine and high temperatures shorten telomeres. Additional treatments, such as oxidative stress, show no effect. By combining genome-wide expression measurements with a systematic genetic screen, we identify the Rap1/Rif1 pathway as the central mediator of the telomeric response to environmental signals. These results demonstrate that telomere length can be manipulated, and that a carefully regulated homeostasis may become markedly deregulated in opposing directions in response to different environmental cues.

  14. Extending electronic length frequency analysis in R

    DEFF Research Database (Denmark)

    Taylor, M. H.; Mildenberger, Tobias K.

    2017-01-01

    of the asymptotic length parameter (L-infinity) are found to have significant effects on parameter estimation error. An outlook provides context as to the significance of the R-based implementation for further testing and development, as well as the general relevance of the method for data-limited stock assessment.......Electronic length frequency analysis (ELEFAN) is a system of stock assessment methods using length-frequency (LFQ) data. One step is the estimation of growth from the progression of LFQ modes through time using the von Bertalanffy growth function (VBGF). The option to fit a seasonally oscillating...... with known values, the accuracy of the soVBGF parameter estimation was evaluated. The results indicate that both optimisation approaches are capable of finding high scoring solutions, yet settings regarding the initial restructuring process for LFQ bin scoring (i.e. "moving average,") and the fixing...

  15. Resonance effects in neutron scattering lengths

    International Nuclear Information System (INIS)

    Lynn, J.E.

    1989-01-01

    The nature of neutron scattering lengths is described and the nuclear effects giving rise to their variation is discussed. Some examples of the shortcomings of the available nuclear data base, particularly for heavy nuclei, are given. Methods are presented for improving this data base, in particular for obtaining the energy variation of the complex coherent scattering length from long to sub-angstrom wave lengths from the available sources of slow neutron cross section data. Examples of this information are given for several of the rare earth nuclides. Some examples of the effect of resonances in neutron reflection and diffraction are discussed. This report documents a seminar given at Argonne National Laboratory in March 1989. 18 refs., 18 figs

  16. Minimal Length Scale Scenarios for Quantum Gravity.

    Science.gov (United States)

    Hossenfelder, Sabine

    2013-01-01

    We review the question of whether the fundamental laws of nature limit our ability to probe arbitrarily short distances. First, we examine what insights can be gained from thought experiments for probes of shortest distances, and summarize what can be learned from different approaches to a theory of quantum gravity. Then we discuss some models that have been developed to implement a minimal length scale in quantum mechanics and quantum field theory. These models have entered the literature as the generalized uncertainty principle or the modified dispersion relation, and have allowed the study of the effects of a minimal length scale in quantum mechanics, quantum electrodynamics, thermodynamics, black-hole physics and cosmology. Finally, we touch upon the question of ways to circumvent the manifestation of a minimal length scale in short-distance physics.

  17. Nuclear reactor with scrammable part length rod

    International Nuclear Information System (INIS)

    Bevilacqua, F.

    1979-01-01

    A new part length rod is provided. It may be used to control xenon induced power oscillations but to contribute to shutdown reactivity when a rapid shutdown of the reactor is required. The part length rod consists of a control rod with three regions. The lower control region is a longer weaker active portion separated from an upper stronger shorter poison section by an intermediate section which is a relative non-absorber of neutrons. The combination of the longer weaker control section with the upper high worth poison section permits the part length rod of this to be scrammed into the core when a reactor shutdown is required but also permits the control rod to be used as a tool to control power distribution in both the axial and radial directions during normal operation

  18. Minimal Length Scale Scenarios for Quantum Gravity

    Directory of Open Access Journals (Sweden)

    Sabine Hossenfelder

    2013-01-01

    Full Text Available We review the question of whether the fundamental laws of nature limit our ability to probe arbitrarily short distances. First, we examine what insights can be gained from thought experiments for probes of shortest distances, and summarize what can be learned from different approaches to a theory of quantum gravity. Then we discuss some models that have been developed to implement a minimal length scale in quantum mechanics and quantum field theory. These models have entered the literature as the generalized uncertainty principle or the modified dispersion relation, and have allowed the study of the effects of a minimal length scale in quantum mechanics, quantum electrodynamics, thermodynamics, black-hole physics and cosmology. Finally, we touch upon the question of ways to circumvent the manifestation of a minimal length scale in short-distance physics.

  19. Research on recognition of ramp angle based on transducer

    Directory of Open Access Journals (Sweden)

    Wenhao GU

    2015-12-01

    Full Text Available Focusing on the recognition of ramp angle, the relationship between the signal of vehicle transducer and real ramp angle is studied. The force change of vehicle on the ramp, and the relationship between the body tilt angle and front and rear suspension scale is discussed. According to the suspension and tire deformation, error angle of the ramp angle is deduced. A mathematical model is established with Matlab/Simulink and used for simulation to generate error curve of ramp angle. The results show that the error angle increases with the increasing of the ramp angle, and the limit value can reach 6.5%, while the identification method can effectively eliminate this error, and enhance the accuracy of ramp angle recognition.

  20. The effect of beam angle in abrasive-waterjet machining

    International Nuclear Information System (INIS)

    Hashish, M.

    1989-01-01

    In the machining of materials, abrasive-waterjets are typically applied at a 90-degree angle to the surface of the workpiece. This paper presents results and observations on machining with abrasive-waterjets at angles other than 90 degrees. Previous visualization studies of the cutting process in transparent materials has shown that there are optimal angles for maximum depth of cut and kerf depth uniformity. Here, observations on the effect of angle in machining applications, such as turning, milling. linear cutting, and drilling, are addressed. The effects of variations in both the impact angle and the rake angle are investigated. Results indicate that the volume removal rate is significantly affected by these angles and that surface finish can be improved by angling the jet. However, shallow angle drilling of small holes in laminated or ceramic-coated materials requires further investigation

  1. New plasma diagnosis by coherence length spectroscopy

    International Nuclear Information System (INIS)

    Poolyarat, N.; Kim, Y.W.

    2008-01-01

    A new methodology and instrumentation have been developed for diagnosis of dense high temperature plasmas. In a plasma medium, collision processes shorten the optical coherence length at a given emission wavelength. By measuring the coherence length, the rate of collisions a radiating particle experiences can be determined. A map of the collision rates throughout the plasma can speak volumes about the atomic and thermal state of the plasma. Both the time-integrated and time-resolved interference fringes are obtained using emissions due to the transition between 3s 2 3p 5 ( 2 P o 3/2 )4p and 3s 2 3p 5 ( 2 P o 3/2 )7d. We have observed that the coherence length indeed decreases with increasing collision rate, and in addition, as a function of time as a result of cumulative collisions. The coherence length was found to be 4200±800 nm at 50 torr where the collision frequency is 2.14x10 11 s -1 , and 2400±130 nm at 140 torr where the collision frequency is 8.13x10 11 s -1 . We have also discovered that the coherence length varies with the direction of the viewing line of sight into the discharge plasma. The anisotropy results from the non-uniform structure in the discharge current, and this is further investigated by intentionally deforming the tip of the cathode. A photographic examination of both the cathode and the anode disc confirms the non-axis-symmetric structure of the plasma, which leads to the asymmetry in the plasma, in agreement with the angular dependence of the coherence length. (author)

  2. Sighting optics including an optical element having a first focal length and a second focal length

    Science.gov (United States)

    Crandall, David Lynn [Idaho Falls, ID

    2011-08-01

    One embodiment of sighting optics according to the teachings provided herein may include a front sight and a rear sight positioned in spaced-apart relation. The rear sight includes an optical element having a first focal length and a second focal length. The first focal length is selected so that it is about equal to a distance separating the optical element and the front sight and the second focal length is selected so that it is about equal to a target distance. The optical element thus brings into simultaneous focus, for a user, images of the front sight and the target.

  3. Cutting Whole Length or Partial Length of Internal Anal Sphincter in Managementof Fissure in Ano

    Directory of Open Access Journals (Sweden)

    Furat Shani Aoda

    2017-12-01

    Full Text Available A chronic anal fissure is a common painful perianal condition.The main operative procedure to treat this painful condition is a lateral internal sphincteretomy (LIS.The aim of study is to compare the outcome and complications of closed LIS up to the dentate line (whole length of internal sphincter or up to the fissure apex (partial length of internal sphincter in the treatment of anal fissure.It is a prospective comparativestudy including 100 patients with chronic fissure in ano. All patients assigned to undergo closed LIS. Those patients were randomly divided into two groups: 50 patients underwent LIS to the level of dentate line (whole length and other 50 patients underwent LIS to the level of fissure apex (partial length. Patients were followed up weekly in the 1st month, twice monthly in the second month then monthly   for next 2 months and finally after 1 year. There was satisfactory relief of pain in all patients in both groups & complete healing of the fissure occurred. Regarding post operative incontinence no major degree of incontinence occur in both group but minor degree of incontinence persists In 7 patients after whole length LIS after one year. In conclusion, both whole length & partial length LIS associated with improvement of pain, good chance of healing but whole length LIS associated with more chance of long term  flatus incontinence. Hence,we recommend partial length LIS as treatment forchronic anal fissure.

  4. Apparatus for fabricating continuous lengths of superconductor

    Science.gov (United States)

    Kroeger, Donald M.; List, III, Frederick A.

    2001-01-01

    A process and apparatus for manufacturing a superconductor. The process is accomplished by depositing a superconductor precursor powder on a continuous length of a first substrate ribbon, overlaying a continuous length of a second substrate ribbon on said first substrate ribbon, and applying sufficient pressure to form a bound layered superconductor comprising a layer of said superconducting precursor powder between said first substrate ribbon and said second substrates ribbon. The layered superconductor is then heat treated to establish the superconducting phase of said superconductor precursor powder.

  5. Stride length: measuring its instantaneous value

    International Nuclear Information System (INIS)

    Campiglio, G C; Mazzeo, J R

    2007-01-01

    Human gait has been studied from different viewpoints: kinematics, dynamics, sensibility and others. Many of its characteristics still remain open to research, both for normal gait and for pathological gait. Objective measures of some of its most significant spatial/temporal parameters are important in this context. Stride length, one of these parameters, is defined as the distance between two consecutive contacts of one foot with ground. On this work we present a device designed to provide automatic measures of stride length. Its features make it particularly appropriate for the evaluation of pathological gait

  6. Study liquid length penetration results obtained with a direct acting piezo electric injector

    International Nuclear Information System (INIS)

    Payri, Raul; Gimeno, Jaime; Bardi, Michele; Plazas, Alejandro H.

    2013-01-01

    Highlights: ► A direct acting injector capable of controlling needle lift has been used to determine liquid phase penetration. ► The influence of injection pressure, chamber density and chamber temperature have been measured. ► When needle lift is reduced the stabilized liquid length is shortened. ► The relationship between needle lift and liquid length makes needle lift as a new way to control the injection event. - Abstract: A state of the art prototype common rail injector featuring direct control of the needle by means of a piezo stack (direct acting) has been tested. Liquid phase penetration of the sprays in diesel engine-like conditions has been studied via imaging technique in a novel continuous flow test chamber that allows an accurate control on a wide range of thermodynamic conditions (up to 1000 K and 15 MPa). This state of the art injector fitted with a 7-hole nozzle, allows a fully flexible control on the nozzle needle movement, enabling various fuel injection rate typologies. The temporal evolution of the seven sprays has been studied recording movies of the injection event in evaporative conditions via Mie scattering imaging technique and using a high speed camera. The results showed a strong influence of needle position on the stabilized liquid length while the effect of the injection pressure is negligible: the decrease of the needle lift causes a pressure drop in the needle seat and thus a reduction in the effective pressure upstream of the orifices (in the nozzle sac). According to known literature the stabilized liquid-length depends mainly on effective diameter, spray cone-angle and fuel/air properties and does not depend on fuel velocity at the orifice outlet. Therefore, due to small change in the spray cone-angle, higher injection pressures give slightly lower liquid length. However, partial needle lifts has an opposite effect: when needle is partially lifted a dramatic increase of the spray cone-angle and a consequent reduction of

  7. Structure and properties of aqueous methylcellulose gels by small-angle neutron scattering.

    Science.gov (United States)

    Chatterjee, Tirtha; Nakatani, Alan I; Adden, Roland; Brackhagen, Meinolf; Redwine, David; Shen, Hongwei; Li, Yongfu; Wilson, Tricia; Sammler, Robert L

    2012-10-08

    Cold, semidilute, aqueous solutions of methylcellulose (MC) are known to undergo thermoreversible gelation when warmed. This study focuses on two MC materials with much different gelation performance (gel temperature and hot gel modulus) even though they have similar metrics of their coarse-grained chemical structure (degree-of-methylether substitution and molecular weight distribution). Small-angle neutron scattering (SANS) experiments were conducted to probe the structure of the aqueous MC materials at pre- and postgel temperatures. One material (MC1, higher gel temperature) exhibited a single almost temperature-insensitive gel characteristic length scale (ζ(c) = 1090 ± 50 Å) at postgelation temperatures. This length scale is thought to be the gel blob size between network junctions. It also coincides with the length scale between entanglement sites measured with rheology studies at pregel temperatures. The other material (MC2, lower gel temperature) exhibited two distinct length scales at all temperatures. The larger length scale decreased as temperature increased. Its value (ζ(c1) = 1046 ± 19 Å) at the lowest pregel temperature was indistinguishable from that measured for MC1, and reached a limiting value (ζ(c1) = 450 ± 19 Å) at high temperature. The smaller length scale (ζ(c2) = 120 to 240 Å) increased slightly as temperature increased, but remained on the order of the chain persistence length (130 Å) measured at pregel temperatures. The smaller blob size (ζ(c1)) of MC2 suggests a higher bond energy or a stiffer connectivity between network junctions. Moreover, the number density of these blobs, at the same reduced temperature with respect to the gel temperature, is orders of magnitude higher for the MC2 gels. Presumably, the smaller gel length scale and higher number density lead to higher hot gel modulus for the low gel temperature material.

  8. [Measurement of the lumbosacral angle and its clinical significance].

    Science.gov (United States)

    Bene, E

    1981-01-01

    The author reports about the result of a series of investigations and tests concerning the angle of the L-S vertebral column. Different factors influencing the values of L-S angle are analyzed. The clinical importance of the respective angles is small, the statics of the L-S transition is determined by all angles together. The reduced L-S angle cannot be considered as an aetiological factor of the spondylolysthesis. The pathological angle values as well as the positions play a role in the induction of the discopathy

  9. Skin Absorbed Doses from Full Mouth Standard Intraoral Radiography in Bisecting Angle and Paralleling techniques

    Energy Technology Data Exchange (ETDEWEB)

    Nah, Kyung Soo; Kim, Ae Ji [Dept. of Oral Radiology, College of Dentistry, Pusan National University, Pusan (Korea, Republic of); Doh, Shi Hong [Dept. of Applied physics . National Fisheries University of Pusan Department of Radiotherapy, Pusan (Korea, Republic of); Kim, Hyun Ja [Dept. of Oral Radiology, Baptist Hospital, Pusan (Korea, Republic of); Yoo, Meong Jin [Dept. of Radiology, College of Dentistry, Pusan National University, Pusan (Korea, Republic of)

    1990-08-15

    This study was performed to measure the skin absorbed doses from full mouth standard intraoral radiography(14 exposures) in bisecting angle and paralleling techniques. Thermoluminescent dosimeters were used in a phantom. Circular tube collimator (60 mm in diameter, 20 cm in length) and rectangular collimator (35 mm X 44 mm, 40 cm in length) were set for bisecting angle and paralleling techniques respectively. All measurement sites were classified into 8 groups according to distance from each point of central rays. The results were as follows: 1. The skin absorbed doses from the paralleling technique were significantly decreased than those from the bisecting technique in both points at central ray and points away from central ray. The percentage rats of decrease were greater at points away from central ray than those at central ray. 2. The skin absorbed doses at the lens of eye, parotid gland, submandibular gland and thyroid region were significantly decreased in paralleling technique, but those of the midline of palate remained similar in both techniques. 3. The highest doses were measured at the site 20 mm above the point of central ray for the mandibular premolars in bisecting angle technique and at the point of central ray for the mandibular premolars in paralleling techniques. The lowest doses were measured at the thyroid region in both techniques.

  10. Skin Absorbed Doses from Full Mouth Standard Intraoral Radiography in Bisecting Angle and Paralleling techniques

    International Nuclear Information System (INIS)

    Nah, Kyung Soo; Kim, Ae Ji; Doh, Shi Hong; Kim, Hyun Ja; Yoo, Meong Jin

    1990-01-01

    This study was performed to measure the skin absorbed doses from full mouth standard intraoral radiography(14 exposures) in bisecting angle and paralleling techniques. Thermoluminescent dosimeters were used in a phantom. Circular tube collimator (60 mm in diameter, 20 cm in length) and rectangular collimator (35 mm X 44 mm, 40 cm in length) were set for bisecting angle and paralleling techniques respectively. All measurement sites were classified into 8 groups according to distance from each point of central rays. The results were as follows: 1. The skin absorbed doses from the paralleling technique were significantly decreased than those from the bisecting technique in both points at central ray and points away from central ray. The percentage rats of decrease were greater at points away from central ray than those at central ray. 2. The skin absorbed doses at the lens of eye, parotid gland, submandibular gland and thyroid region were significantly decreased in paralleling technique, but those of the midline of palate remained similar in both techniques. 3. The highest doses were measured at the site 20 mm above the point of central ray for the mandibular premolars in bisecting angle technique and at the point of central ray for the mandibular premolars in paralleling techniques. The lowest doses were measured at the thyroid region in both techniques.

  11. Probing mesoscopic structures in hierarchically structured materials and porous media by small-angle scattering

    International Nuclear Information System (INIS)

    Sen, D.

    2010-01-01

    Small-angle neutron (SANS) and X-ray scattering (SAXS) are powerful techniques to investigate structural features of inhomogeneities i.e., the density fluctuations in condensed matter, on a length scale ranging from one nanometer up to one micron. 'Structural features' include size or size distribution, shape, dimensionality, inter-particle spatial correlation etc. Mesoscopic structure in hierarchically structured materials, where density fluctuations exist over a wide length scale, may be probed by combined usage of small-angle and ultra small-angle neutron or X-ray scattering. Such hierarchically structured micrometric grains may be synthesized by evaporation induced self assembly of nanoparticles. Rate of drying and physico-chemical properties of the virgin colloidal suspension are important aspects in determining the morphology of the grains as well as the inter-particle interactions within grains. Meso/macro pores can be templated in such grains by adding soft template materials and followed by calcinations. In this lecture, applications of SANS/SAXS on such hierarchically structured grains, synthesized by spray drying technique, will be discussed. In addition, a few applications of SANS/SAXS to probe porous materials and non-Euclidean systems will also be elaborated. In some cases, Monte Carlo based simulations have been performed in order to understand the observations from the scattering experiments and these will also be talked about. (author)

  12. Comparison of calf muscle architecture between Asian children with spastic cerebral palsy and typically developing peers.

    Science.gov (United States)

    Chen, Ying; He, Lu; Xu, Kaishou; Li, Jinling; Guan, Buyun; Tang, Hongmei

    2018-01-01

    To compare the muscle thickness, fascicle length, and pennation angle of the gastrocnemius, soleus, and tibialis anterior between Asian children with spastic cerebral palsy (CP) and typically developing (TD) peers. This cross-sectional study involved a total of 72 children with hemiplegic CP (n = 24), and diplegic CP (n = 24) and their TD peers (n = 24). Muscle architecture was measured at rest using ultrasound. Clinical measures included gross motor function and a modified Ashworth scale. The thicknesses of the tibialis anterior and medial gastrocnemius muscles were smaller in the affected calf of children with CP (ppeers. Additionally, the lengths of the lateral gastrocnemius and soleus fascicle were shorter (ppeers. The fascicle length was shorter in the affected calf of children with CP (ppeers or the unaffected calf of children with hemiplegic CP. However, the length of the lateral gastrocnemius fascicle was similar between the two legs of children with hemiplegic CP. The pennation angles of the medial gastrocnemius and soleus muscles were larger (ppeers. The fascicle length of the lateral gastrocnemius and the thickness of the soleus muscle were positively correlated with gross motor function scores in children with CP (p<0.05). Muscle thickness and fascicle length were lower in the affected tibialis anterior, gastrocnemius, and soleus in children with spastic CP. These changes may limit the ability to stand and walk, and indicate a need to strengthen the affected muscle.

  13. A simple method to obtain consistent and clinically meaningful pelvic angles from euler angles during gait analysis.

    Science.gov (United States)

    Wren, Tishya A L; Mitiguy, Paul C

    2007-08-01

    Clinical gait analysis usually describes joint kinematics using Euler angles, which depend on the sequence of rotation. Studies have shown that pelvic obliquity angles from the traditional tilt-obliquity-rotation (TOR) Euler angle sequence can deviate considerably from clinical expectations and have suggested that a rotation-obliquity-tilt (ROT) Euler angle sequence be used instead. We propose a simple alternate approach in which clinical joint angles are defined and exactly calculated in terms of Euler angles from any rotation sequence. Equations were derived to calculate clinical pelvic elevation, progression, and lean angles from TOR and ROT Euler angles. For the ROT Euler angles, obliquity was exactly the same as the clinical elevation angle, rotation was similar to the clinical progression angle, and tilt was similar to the clinical lean angle. Greater differences were observed for TOR. These results support previous findings that ROT is preferable to TOR for calculating pelvic Euler angles for clinical interpretation. However, we suggest that exact clinical angles can and should be obtained through a few extra calculations as demonstrated in this technical note.

  14. Light-dark changes in iris thickness and anterior chamber angle width in eyes with occludable angles.

    Science.gov (United States)

    Hirose, Fumitaka; Hata, Masayuki; Ito, Shin-ichiro; Matsuki, Takaaki; Kurimoto, Yasuo

    2013-10-01

    The purpose of this study was to investigate and measure light-dark changes in iris thickness (IT) and anterior chamber angle width in eyes with occludable angles and open angles by using anterior segment optical coherence tomography (AS-OCT). We examined 153 eyes of 153 Japanese patients with primary angle closure suspect, primary angle closure, primary angle closure glaucoma, or primary open angle glaucoma. AS-OCT was used to determine pupil diameter, IT, angle opening distance at 500 μm (AOD₅₀₀), and trabecular-iris space area at 500 μm (TISA₅₀₀) in each quadrant of the anterior chamber angle (superior, inferior, temporal, and nasal) under light and dark conditions. In the angle closure cases, IT, AOD₅₀₀ and TISA₅₀₀ in the dark varied significantly among the four quadrants (P dark did not differ significantly among the four quadrants. In the angle closure cases and the open angle cases, significant negative associations were found between IT difference [IT(light)-IT(dark)] and AOD₅₀₀ difference [AOD₅₀₀(light)-AOD₅₀₀(dark)] (R = -0.411, P dark)] (R = -0.475, P dark conditions is related to the mechanism of primary angle closure. It is important to analyze both the angle structure and peripheral IT in each quadrant.

  15. 28 CFR 551.4 - Hair length.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Hair length. 551.4 Section 551.4 Judicial Administration BUREAU OF PRISONS, DEPARTMENT OF JUSTICE INSTITUTIONAL MANAGEMENT MISCELLANEOUS Grooming § 551.4... Warden shall require an inmate with long hair to wear a cap or hair net when working in food service or...

  16. The heritability of leucocyte telomere length dynamics

    DEFF Research Database (Denmark)

    Hjelmborg, Jacob B; Dalgård, Christine; Möller, Sören

    2015-01-01

    BACKGROUND: Leucocyte telomere length (LTL) is a complex trait associated with ageing and longevity. LTL dynamics are defined by LTL and its age-dependent attrition. Strong, but indirect evidence suggests that LTL at birth and its attrition during childhood largely explains interindividual LTL...

  17. Telomere length in interstitial lung diseases

    NARCIS (Netherlands)

    Snetselaar, Reinier; Van Moorsel, Coline H M; Kazemier, Karin M.; Van Der Vis, Joanne J.; Zanen, Pieter; Van Oosterhout, Matthijs F M; Grutters, Jan C.

    2015-01-01

    Background: Interstitial lung disease (ILD) is a heterogeneous group of rare diseases that primarily affect the pulmonary interstitium. Studies have implicated a role for telomere length (TL) maintenance in ILD, particularly in idiopathic interstitial pneumonia (IIP). Here, we measure TL in a wide

  18. Minimum Description Length Shape and Appearance Models

    DEFF Research Database (Denmark)

    Thodberg, Hans Henrik

    2003-01-01

    The Minimum Description Length (MDL) approach to shape modelling is reviewed. It solves the point correspondence problem of selecting points on shapes defined as curves so that the points correspond across a data set. An efficient numerical implementation is presented and made available as open s...

  19. Scattering lengths of calcium and barium isotopes

    NARCIS (Netherlands)

    Dammalapati, U.; Willmann, L.; Knoop, S.

    2011-01-01

    We have calculated the s-wave scattering length of all the even isotopes of calcium (Ca) and barium (Ba) in order to investigate the prospect of Bose-Einstein condensation (BEC). For Ca we have used an accurate molecular potential based on detailed spectroscopic data. Our calculations show that Ca

  20. Hydrodynamic slip length as a surface property

    Science.gov (United States)

    Ramos-Alvarado, Bladimir; Kumar, Satish; Peterson, G. P.

    2016-02-01

    Equilibrium and nonequilibrium molecular dynamics simulations were conducted in order to evaluate the hypothesis that the hydrodynamic slip length is a surface property. The system under investigation was water confined between two graphite layers to form nanochannels of different sizes (3-8 nm). The water-carbon interaction potential was calibrated by matching wettability experiments of graphitic-carbon surfaces free of airborne hydrocarbon contamination. Three equilibrium theories were used to calculate the hydrodynamic slip length. It was found that one of the recently reported equilibrium theories for the calculation of the slip length featured confinement effects, while the others resulted in calculations significantly hindered by the large margin of error observed between independent simulations. The hydrodynamic slip length was found to be channel-size independent using equilibrium calculations, i.e., suggesting a consistency with the definition of a surface property, for 5-nm channels and larger. The analysis of the individual trajectories of liquid particles revealed that the reason for observing confinement effects in 3-nm nanochannels is the high mobility of the bulk particles. Nonequilibrium calculations were not consistently affected by size but by noisiness in the smallest systems.

  1. Information-theoretic lengths of Jacobi polynomials

    Energy Technology Data Exchange (ETDEWEB)

    Guerrero, A; Dehesa, J S [Departamento de Fisica Atomica, Molecular y Nuclear, Universidad de Granada, Granada (Spain); Sanchez-Moreno, P, E-mail: agmartinez@ugr.e, E-mail: pablos@ugr.e, E-mail: dehesa@ugr.e [Instituto ' Carlos I' de Fisica Teorica y Computacional, Universidad de Granada, Granada (Spain)

    2010-07-30

    The information-theoretic lengths of the Jacobi polynomials P{sup ({alpha}, {beta})}{sub n}(x), which are information-theoretic measures (Renyi, Shannon and Fisher) of their associated Rakhmanov probability density, are investigated. They quantify the spreading of the polynomials along the orthogonality interval [- 1, 1] in a complementary but different way as the root-mean-square or standard deviation because, contrary to this measure, they do not refer to any specific point of the interval. The explicit expressions of the Fisher length are given. The Renyi lengths are found by the use of the combinatorial multivariable Bell polynomials in terms of the polynomial degree n and the parameters ({alpha}, {beta}). The Shannon length, which cannot be exactly calculated because of its logarithmic functional form, is bounded from below by using sharp upper bounds to general densities on [- 1, +1] given in terms of various expectation values; moreover, its asymptotics is also pointed out. Finally, several computational issues relative to these three quantities are carefully analyzed.

  2. Link lengths and their growth powers

    International Nuclear Information System (INIS)

    Huh, Youngsik; No, Sungjong; Oh, Seungsang; Rawdon, Eric J

    2015-01-01

    For a certain infinite family F of knots or links, we study the growth power ratios of their stick number, lattice stick number, minimum lattice length and minimum ropelength compared with their minimum crossing number c(K) for every K∈F. It is known that the stick number and lattice stick number grow between the (1/2) and linear power of the crossing number, and minimum lattice length and minimum ropelength grow with at least the (3/4) power of crossing number (which is called the four-thirds power law). Furthermore, the minimal lattice length and minimum ropelength grow at most as O (c(K)[ln(c(K))] 5 ), but it is unknown whether any family exhibits superlinear growth. For any real number r between (1/2) and 1, we give an infinite family of non-splittable prime links in which the stick number and lattice stick number grow exactly as the rth power of crossing number. Furthermore for any real number r between (3/4) and 1, we give another infinite family of non-splittable prime links in which the minimum lattice length and minimum ropelength grow exactly as the rth power of crossing number. (paper)

  3. Complementary DNA-amplified fragment length polymorphism ...

    African Journals Online (AJOL)

    owner

    2011-05-09

    May 9, 2011 ... Complementary DNA-amplified fragment length polymorphism (cDNA-AFLP) technology was used to analyze ... that 9 of the studied expressed sequence tags (ESTs) are related to protein modification, 12 ESTs are involved in the .... primers were used during the first strand synthesis of our cDNA synthesis ...

  4. Fetal Umbilical Cord Length and Associated Intrapatum ...

    African Journals Online (AJOL)

    Shoulder dystocia, hand prolapse in a transverse lying fetus, abruptio placentae and prolonged second stage of labour had shorter cords while fetal distress, cord prolapse and mecunium stained liquor had longer cords when compared with the mean umbilical cord length of the study population. Conclusion: Umbilical cord ...

  5. Relationship of the Gonial Angle and Inferior Alveolar Canal Course Using Cone Beam Computed Tomography

    Directory of Open Access Journals (Sweden)

    Najmeh Anbiaee

    2016-03-01

    Full Text Available Objectives: Accurate localization of the inferior alveolar canal (IAC is extremely important in some dental treatments. Anatomical variation of the canal means that it can be difficult to locate. The purpose of this study was to assess the relationship of the gonial angle (GA size and IAC position using cone beam computed tomography (CBCT.Materials and Methods: In this in vitro study, 61 dry adult human hemi-mandibles were used. The CBCT scans were taken of all samples and GA was measured on all CBCT scans. The samples were divided into two groups of low angle (≤125° and high angle (>125°. The canal dimensions, length and course were evaluated. On the sagittal view, the IAC path was classified as type A, B or C. On the axial view, canal course was defined as A1 or A2 according to the mental foramen angle.Results: The average GA size was 121.8±7.05° at the right side and 123.8±6.32° at the left side. On the sagittal view, there was a significant correlation between the GA size and the canal course (P=0.04. In the high-angle group, type A was dominant; whereas in the low-angle group, type B was more common. On the axial view of IAC course, type A1 was more common (73.43%.Conclusion: The results showed that GA size was associated with IAC course. In cases with a larger GA, the canal runs in a more straightforward path, and at the same level as the mental foramen.Keywords: Cone Beam Computed Tomography; Mandibular Nerve; Mandible

  6. X-ray small angle scattering of polymer solutions

    International Nuclear Information System (INIS)

    Koyama, Ryuzo

    1975-01-01

    In recent papers, the calculated results were reported on the angular dependence of the intensity of scattered light or X-ray by chain polymers, on the basis of a stiff chain model. As the results, the curves of S 2 P (theta) corresponding to Kratky plot, for different molecular expansion, showed a plateau, and the height of the plateau was proportional to the inverse of molecular expansion coefficient α 2 . But as seen later, there is some possibility that the assumption made in the calculation overestimated the expansion of small segments which theoretically determines scattering curves at large scattering angles, such as the plateau. Accordingly, modified calculation was carried out by adopting the stiff chain polymer model as the previous case. When the contour length of a chain segment is very long, it can be treated approximately as a Gaussian coil, thus the equation for a chain segment expansion coefficient α (t) was obtained. Then the mean square distance of chain segments of polymer molecules was able to be determined, and the equation for a particle scattering factor P(theta) was obtained. The numerical calculation of P(theta) showed that this modified assumption considerably decreased the effect of molecular expansion on P(theta), and the curves of S 2 P(theta) increased monotonously without showing the plateau. The result of this calculation was compared with the experimental curves of polystyrene-toluene solution, and the agreement better than before was obtained. (Kako, I.)

  7. Ideal screw entry point and projection angles for posterior lateral mass fixation of the atlas: an anatomical study

    Science.gov (United States)

    Simsek, Serkan; Seçkin, Hakan; Comert, Ayhan; Acar, Halil I.; Belen, Deniz; Tekdemir, Ibrahim; Elhan, Alaittin

    2009-01-01

    Although various posterior insertion angles for screw insertion have been proposed for C1 lateral mass, substantial conclusions have not been reached regarding ideal angles and average length of the screw yet. We aimed to re-consider the morphometry and the ideal trajections of the C1 screw. Morphometric analysis was performed on 40 Turkish dried atlas vertebrae obtained from the Department of Anatomy at the Medical School of Ankara University. The quantitative anatomy of the screw entry zone, trajectories, and the ideal lengths of the screws were calculated to evaluate the feasibility of posterior screw fixation of the lateral mass of the atlas. The entry point into the lateral mass of the atlas is the intersection of the posterior arch and the C1 lateral mass. The optimum medial angle is 13.5 ± 1.9° and maximal angle of medialization is 29.4 ± 3.0°. The ideal cephalic angle is 15.2 ± 2.6°, and the maximum cephalic angle is 29.6 ± 2.6°. The optimum screw length was found to be 19.59 ± 2.20 mm. With more than 30° of medial trajections and cephalic trajections the screw penetrates into the spinal canal and atlantooccipital joint, respectively. Strikingly, in 52% of our specimens, the height of the inferior articular process was under 3.5 mm, and in 70% was under 4 mm, which increases the importance of the preparation of the screw entry site. For accommodation of screws of 3.5-mm in diameter, the starting point should be taken as the insertion of the posterior arch at the superior end of the inferior articular process with a cephalic trajection. This study may aid many surgeons in their attempts to place C1 lateral mass screws. PMID:19644713

  8. Angle parameter changes of phacoemulsification and combined phacotrabeculectomy for acute primary angle closure

    Directory of Open Access Journals (Sweden)

    Shi-Wei Li

    2015-08-01

    Full Text Available AIM: To evaluate the difference in angle parameters and clinical outcome following phacoemulsification and combined phacotrabeculectomy in patients with acute primary angle closure (APAC using ultrasound biomicroscopy (UBM.METHODS: Patients (n=23, 31 eyes were randomized to receive phacoemulsification or combined phacotrabeculectomy (n=24, 31 eyes. Best-corrected visual acuity (BCVA, intraocular pressure (IOP, the main complications following surgery, and indentation gonioscopy and angle parameters measured using UBM were documented preoperatively and postoperatively.RESULTS:The improvement in BCVA in the phacoemulsification group was significantly greater than in the combined group (P<0.05. IOP in the phacoemulsification group was slightly higher than in the combined group following 1wk of follow-up (P<0.05, whereas there was no significant difference between the two groups at the latter follow-up (P>0.05. Phacoemulsification alone resulted in a slight increase in the trabecular ciliary processes distance compared with the combined surgery (P<0.05, whereas the other angle parameters showed no significant difference between the groups. Complications in combined group were greater than phacoemulsification only group.CONCLUSION:Both surgeries effectively opened the drainage angle and deepened the anterior chamber, and IOP was well controlled postoperatively. However, phacoemulsification showed better efficacy in improving visual function and showed reduced complications following surgery.

  9. Optimum transfer between hyperbolic asymptotes with turn angle less than the maximum natural turn angle.

    Science.gov (United States)

    Walton, J. M.; Marchal, C.; Culp, R. D.

    1971-01-01

    The impulsive transfer of minimum characteristic velocity between two given hyperbolic asymptotes associated with a real planet is considered. The constraint of remaining above the surface of the planet introduces a maximum natural turn angle. This divides the problem naively into two categories. The first is the case when the turn angle required by the given asymptotes is less than or equal to the maximum natural turn angle. This is the more reasonable situation for a swingby maneuver, and is the case considered in this paper. The resulting optimal transfers are of five basic types. In boundary conditions space, by far the largest area of transfers are either single impulse transfers or transfers through the parabolic level requiring two finite impulses. In no case has an optimal transfer been found which uses more than two finite impulses and three infinitesimal impulses. Complete results are presented for the case in which the given turn angle is less than or equal to the maximum natural turn angle.

  10. A variable angle slant-hole collimator

    International Nuclear Information System (INIS)

    Moore, R.H.; Alpert, N.M.; Strauss, H.W.

    1983-01-01

    A variable-angle slant-hole (VASH) collimator was constructed to show the feasibility of using multiple sliding plates to achieve a range of collimator channel inclinations. One hundred and sixty tungsten plates, 0.125 mm thick and 14 cm square, were photoetched to produce 3025 1.5-mm2 holes in each plate, separated by 0.8-mm septa. Along with the collimator holes, registration holes and positioning grooves were also etched. The plates were placed in a holder and stacked to form a collimator 2.0 cm high. The holder permitted the plates to be sheared to achieve viewing angles from 0 to 40 degrees from the vertical. Resolution and sensitivity were determined both across and along the shear directions. Resolution of a thin /sup 99m/Tc source, 1.24 mm diam and 7 cm long, located 5 cm from the collimator face in air, was 1.1 cm FWHM at 0 degree shear and remained unchanged with increasing slant. The resolution was similar both across and along the shear plane. Sensitivity was determined with a point source placed 7 cm from the collimator face. At 0 degree slant the sensitivity was 169 cps/MBq (6.24 csp/mu Ci). A general all purpose (GAP) collimator had a FWHM of 1 cm for the line source in air at 5 cm, and a sensitivity of 205 cps/MBq (7.58 cps/mu Ci) for the point source at 7 cm. The data suggest that a variable-angle slant-hole collimator can be constructed of laminated plates

  11. On the ratios of Arc lengths to chord lengths in real Banach spaces ...

    African Journals Online (AJOL)

    Two new moduli are introduced to study the ratios of arc lengths to chord lengths in Banach spaces. Basic properties of those two moduli and the relation between them are studied. The relation between those two moduli and some geometric properties, including uniform convexity, uniform nonsquareness, and uniform ...

  12. The Sphaleron at finite mixing angle

    International Nuclear Information System (INIS)

    Klinkhamer, F.R.; Laterveer, R.

    1990-01-01

    The exact Sphaleron solution in the bosonic sector of the electro-weak standard model is only known for weak mixing angle θ W =0. To investigate the behaviour closer to the experimental value θ W exp approx 30 deg a non-contractible loop in configuration space which is sensitive to θ W is constructed. The numerical results for the energy and the magnetic dipole moment indicate that the dependence on θ W is rather weak. (author). 8 refs.; 4 figs.; 1 tab

  13. Spin Valve Systems for Angle Sensor Applications

    OpenAIRE

    Johnson, Andrew

    2004-01-01

    A contact-less sensor with the ability to measure over a 360° range has been long sought after in the automotive industry. Such a sensor could be realized by utilizing the angle dependence of the Giant Magneto Resistance (GMR) Effect in a special type of magnetic multilayer called a spin valve arranged in a wheatstone bridge circuit [Spo96]. A spin valve consists of two ferromagnetic layers separated by nonmagnetic spacer layer where the magnetization of one of the ferromagnetic layers is pin...

  14. Pair production in small angle Bhabha scattering

    International Nuclear Information System (INIS)

    Arbuzov, A.B.; Kuraev, Eh.A.; Merenkov, N.P.; Trentadue, L.

    1995-01-01

    The radiative corrections due to a pair production in the small angle high energy e + e - Bhabha scattering are considered. The corrections due to the production of virtual pairs as well as real soft and hard ones are calculated analytically. The collinear and semi-collinear kinematical regions of the hard pair production are taken into account. The results in the leading and next-to-leading logarithmic approximations provide the accuracy of Ο (0.1%). The results of numerical calculations show that the effects of pairs production are to be taken into account in the precise luminosity determination at LEP. 9 refs., 3 figs., 2 tabs

  15. Joining by plating: optimization of occluded angle

    International Nuclear Information System (INIS)

    Dini, J.W.; Johnson, H.R.; Kan, Y.R.

    1978-11-01

    An empirical method has been developed for predicting the minimum angle required for maximum joint strength for materials joined by plating. This is done through a proposed power law failure function, whose coefficients are taken from ring shear and conical head tensile data for plating/substrate combinations and whose exponent is determined from one set of plated-joint data. Experimental results are presented for Al-Ni-Al (7075-T6) and AM363-Ni-AM363 joints, and the failure function is used to predict joint strengths for Al-Ni-Al (2024-T6), UTi-Ni-UTi, and Be-Ti-Be

  16. Rapidly-Indexing Incremental-Angle Encoder

    Science.gov (United States)

    Christon, Philip R.; Meyer, Wallace W.

    1989-01-01

    Optoelectronic system measures relative angular position of shaft or other device to be turned, also measures absolute angular position after device turned through small angle. Relative angular position measured with fine resolution by optoelectronically counting finely- and uniformly-spaced light and dark areas on encoder disk as disk turns past position-sensing device. Also includes track containing coarsely- and nonuniformly-spaced light and dark areas, angular widths varying in proportion to absolute angular position. This second track provides gating and indexing signal.

  17. Weak mixing angles and heavy flavours

    International Nuclear Information System (INIS)

    Jarlskog, C.

    1984-05-01

    The present status of the weak mixing angles, in the standard six quark model, is reviewed. The implications of the recent measurements of the beauty lifetime and branching ratios are discussed, in the framework of the Kobayashi-Maskawa and the Wolfenstein parametrizations. Expectations for B(sup)o - B(sup)-o mixing and consequences for the collider data are given. Other topics briefly reviewed are CP-violation, top quark mass and possible implications of the existence of a fourth family. (author)

  18. Small-angle neutron and dynamic light scattering study of gelatin coacervates

    International Nuclear Information System (INIS)

    Mohanty, B; Bohidar, H.B.; Aswal, V.K.; Goyal, P.S.

    2004-01-01

    The state of intermolecular aggregates and that of folded gelatin molecules could be characterized by dynamic laser light and small-angle neutron scattering experiments, which implied spontaneous segregation of particle sizes preceding coacervation, which is a liquid-liquid phase transition phenomenon. Dynamic light scattering (DLS) data analysis revealed two particle sizes until precipitation was reached. The smaller particles having a diameter of ∼50 nm (stable nanoparticles prepared by coacervation method) were detected in the supernatant, whereas the inter-molecular aggregates having a diameter of ∼400 nm gave rise to coacervation. Small-angle neutron scattering (SANS) experiments revealed that typical mesh size of the networks exist in polymer dense phase (coacervates). Analysis of the SANS structure factor showed the presence of two length scales associated with this system that were identified as the correlation length or mesh size, ξ = 10.6 A of the network and the other is the size of inhomogeneities = 21.4 A. Observations were discussed based on the results obtained from SANS experiments performed in 5% (w/v) gelatin solution at 60 degC (ξ = 50 A, ζ = 113 A) and 5% (w/v) gel at 28 degC (ξ = 47 A, ζ = 115 A) in aqueous phase indicating smaller length scales in coacervate as compared to sol and gel. (author)

  19. Exploring the Tilt-Angle Dependence of electron tunneling across Molecular junction of Self-Assembled Alkanethiols

    DEFF Research Database (Denmark)

    Frederiksen, Thomas; Munuera, C.; Ocal, C.

    2009-01-01

    by contacting the molecular layers with the tip of a conductive force microscope. Measurements done under low-load conditions permit us to obtain reliable tilt-angle and molecular length dependencies of the low-bias conductance through the alkanethiol layers. The observed dependence on tilt-angle is stronger......Electronic transport mechanisms in molecular junctions are investigated by a combination of first-principles calculations and current−voltage measurements of several well-characterized structures. We study self-assembled layers of alkanethiols grown on Au(111) and form tunnel junctions...

  20. Relationships between the root-crown ratio and the loss of occlusal contact and high mandibular plane angle in patients with open bite.

    Science.gov (United States)

    Uehara, Sawako; Maeda, Aya; Tomonari, Hiroshi; Miyawaki, Shouichi

    2013-01-01

    To determine the root-crown (R/C) ratio and dental root length of teeth in patients with open bite and seek any relationships with occlusal contact (OC) and the mandibular plane (Mp) angle. Thirty-one patients with open bite with negative overbite of at least four anterior teeth and 31 control patients with clinically normal overjet and overbite were enrolled. R/C ratios, dental root length, OC, and Mp angle were measured using panoramic radiographs, dental casts, and cephalograms, respectively. Mean differences between the groups, and variations between the R/C ratio or root length and Mp angle in patients with open bite were statistically analyzed. R/C and OC ratios from the incisors to premolars were significantly lower for patients with open bite than for controls, and some teeth had short dental roots. Relationships between low R/C ratio or root length and high Mp angle were significant in patients with open bite. Patients with open bite, especially those with a high Mp angle, have an unfavorable R/C ratio and short dental roots in some teeth, which may be related to the loss of OC.

  1. Ocular Biometry in Primary Angle-Closure Glaucoma Associated with Retinitis Pigmentosa

    Directory of Open Access Journals (Sweden)

    Jiangang Xu

    2017-01-01

    Full Text Available Background. Retinitis pigmentosa (RP comprises a group of inherited disorders in which patients typically lose night vision in adolescence and then lose peripheral vision in young adulthood before eventually losing central vision later in life. A retrospective case-control study was performed to evaluate differences in ocular biometric parameters in primary angle-closure glaucoma (PACG patients with and without concomitant RP to determine whether a relationship exists between PACG and RP. Methods. We used ultrasound biomicroscopy (UBM to measure anterior chamber depth (ACD. A-scan biometry was carried out to measure lens thickness (LT and axial length (AL. Propensity score matching and mixed linear regression model analysis were conducted. 23 patients with chronic primary angle-closure glaucoma (CPACG associated with RP, 21 patients with acute primary angle-closure glaucoma (APACG associated with RP, 270 patients with CPACG, and 269 patients with APACG were recruited for this study. Results. There were no significant differences on ACDs, ALs, and relative lens position (RLP (P>0.05 between patients with PACG associated with RP and patients with PACG; however, patients with APACG associated with RP had a significantly greater LT than patients with APACG (P<0.05. Conclusion. Patients with PACG associated with RP had the same biometric parameter characteristic as the patients with CPACG and APACG. This may suggest that RP is a coincidental relationship with angle-closure glaucoma.

  2. Discharge Coefficient Measurements for Flow Through Compound-Angle Conical Holes with Cross-Flow

    Directory of Open Access Journals (Sweden)

    M. E. Taslim

    2004-01-01

    Full Text Available Diffusion-shaped film holes with compound angles are currently being investigated for high temperature gas turbine airfoil film cooling. An accurate prediction of the coolant blowing rate through these film holes is essential in determining the film effectiveness. Therefore, the discharge coefficients associated with these film holes for a range of hole pressure ratios is essential in designing airfoil cooling circuits. Most of the available discharge coefficient data in open literature has been for cylindrical holes. The main objective of this experimental investigation was to measure the discharge coefficients for subsonic as well as supersonic pressure ratios through a single conical-diffusion hole. The conical hole has an exit-to-inlet area ratio of 4, a nominal flow length-to-inlet diameter ratio of 4, and an angle with respect to the exit plane (inclination angle of 0°, 30°, 45°, and 60°. Measurements were performed with and without a cross-flow. For the cases with a cross-flow, discharge coefficients were measured for each of the hole geometries and 5 angles between the projected conical hole axis and the cross-flow direction of 0°, 45°, 90°, 135°, and 180°. Results are compared with available data in open literature for cylindrical film holes as well as limited data for conical film holes.

  3. Determination of dimensions and angles of mandible in the fetal period.

    Science.gov (United States)

    Malas, Mehmet Ali; Ungör, Bahadir; Tağil, S Murat; Sulak, Osman

    2006-08-01

    The aim of the present study was to determine the dimensions of the mandible during the fetal period, the relationship between the growth rates of the angle of the mandible and the dimensions of the mandible. Furthermore the angle of union of the two halves of the body of the mandible on the horizontal mandibular plane, which was not described elsewhere, is explored in this study. One hundred and sixty-one human fetuses (83 males and 78 females) without any cranio-facial or mandibular asymmetry, external pathology or anomaly and aged between 9 and 40 weeks of gestation were used in the study. Cases were stratified into four groups according to their developmental ages, that is, first trimester, second trimester, third trimester, and term fetuses. Cranio-facial parameters in addition to bi-condylar, bi-gonial, bi-mental tubercular, condyle-gonion, gonion-mental tubercle, condyle-mental tubercle, gonion-pogonion distances were measured. The degree of the angle of the mandible, angle of union of the two halves of the body of the mandible and sagittal length of the base of the mandible were calculated. The means of the parameters with respect to gestational weeks and groups were computed. While there were no sex differences in any of the parameters (P>0.05) there were very significant relationships between gestational age and parameters (Pmorphometric features and architectural changes observed in the mandible do not totally occur during the fetal period but continue later in childhood and adulthood.

  4. Medial Longitudinal Arch Angle Presents Significant Differences Between Foot Types: A Biplane Fluoroscopy Study.

    Science.gov (United States)

    Balsdon, Megan E R; Bushey, Kristen M; Dombroski, Colin E; LeBel, Marie-Eve; Jenkyn, Thomas R

    2016-10-01

    The structure of the medial longitudinal arch (MLA) affects the foot's overall function and its ability to dissipate plantar pressure forces. Previous research on the MLA includes measuring the calcaneal-first metatarsal angle using a static sagittal plane radiograph, a dynamic height-to-length ratio using marker clusters with a multisegment foot model, and a contained angle using single point markers with a multisegment foot model. The objective of this study was to use biplane fluoroscopy to measure a contained MLA angle between foot types: pes planus (low arch), pes cavus (high arch), and normal arch. Fifteen participants completed the study, five from each foot type. Markerless fluoroscopic radiostereometric analysis (fRSA) was used with a three-dimensional model of the foot bones and manually matching those bones to a pair of two-dimensional radiographic images during midstance of gait. Statistically significant differences were found between barefoot arch angles of the normal and pes cavus foot types (p = 0.036), as well as between the pes cavus and pes planus foot types (p = 0.004). Dynamic walking also resulted in a statistically significant finding compared to the static standing trials (p = 0.014). These results support the classification of individuals following a physical assessment by a foot specialist for those with pes cavus and planus foot types. The differences between static and dynamic kinematic measurements were also supported using this novel method.

  5. Edge contact angle and modified Kelvin equation for condensation in open pores.

    Science.gov (United States)

    Malijevský, Alexandr; Parry, Andrew O; Pospíšil, Martin

    2017-08-01

    We consider capillary condensation transitions occurring in open slits of width L and finite height H immersed in a reservoir of vapor. In this case the pressure at which condensation occurs is closer to saturation compared to that occurring in an infinite slit (H=∞) due to the presence of two menisci that are pinned near the open ends. Using macroscopic arguments, we derive a modified Kelvin equation for the pressure p_{cc}(L;H) at which condensation occurs and show that the two menisci are characterized by an edge contact angle θ_{e} that is always larger than the equilibrium contact angle θ, only equal to it in the limit of macroscopic H. For walls that are completely wet (θ=0) the edge contact angle depends only on the aspect ratio of the capillary and is well described by θ_{e}≈sqrt[πL/2H] for large H. Similar results apply for condensation in cylindrical pores of finite length. We test these predictions against numerical results obtained using a microscopic density-functional model where the presence of an edge contact angle characterizing the shape of the menisci is clearly visible from the density profiles. Below the wetting temperature T_{w} we find very good agreement for slit pores of widths of just a few tens of molecular diameters, while above T_{w} the modified Kelvin equation only becomes accurate for much larger systems.

  6. Beam dynamics of the interaction region solenoid in a linear collider due to a crossing angle

    Directory of Open Access Journals (Sweden)

    P. Tenenbaum

    2003-06-01

    Full Text Available Future linear colliders may require a nonzero crossing angle between the two beams at the interaction point (IP. This requirement in turn implies that the beams will pass through the strong interaction region solenoid with an angle, and thus that the component of the solenoidal field perpendicular to the beam trajectory is nonzero. The interaction of the beam and the solenoidal field in the presence of a crossing angle will cause optical effects not observed for beams passing through the solenoid on axis; these effects include dispersion, deflection of the beam, and synchrotron radiation effects. For a purely solenoidal field, the optical effects which are relevant to luminosity exactly cancel at the IP when the influence of the solenoid’s fringe field is taken into account. Beam size growth due to synchrotron radiation in the solenoid is proportional to the fifth power of the product of the solenoidal field, the length of the solenoid, and the crossing angle. Examples based on proposed linear collider detector solenoid configurations are presented.

  7. Long range correlations and folding angle with applications to α-helical proteins

    Science.gov (United States)

    Krokhotin, Andrey; Nicolis, Stam; Niemi, Antti J.

    2014-03-01

    The conformational complexity of chain-like macromolecules such as proteins and other linear polymers is much larger than that of point-like atoms and molecules. Unlike particles, chains can bend, twist, and even become knotted. Thus chains might also display a much richer phase structure. Unfortunately, it is not very easy to characterize the phase of a long chain. Essentially, the only known attribute is the radius of gyration. The way how it changes when the degree of polymerization becomes different, and how it evolves when the ambient temperature and solvent properties change, is commonly used to disclose the phase. But in any finite length chain there are corrections to scaling that complicate the detailed analysis of the phase structure. Here we introduce a quantity that we call the folding angle to identify and scrutinize the phase structure, as a complement to the radius of gyration. We argue for a mean-field level relationship between the folding angle and the scaling exponent in the radius of gyration. We then estimate the value of the folding angle in the case of crystallographic α-helical protein structures in the Protein Data Bank. We also show how the experimental value of the folding angle can be obtained computationally, using a semiclassical Born-Oppenheimer description of α-helical chiral chains.

  8. Shear Capacity of C-Shaped and L-Shaped Angle Shear Connectors.

    Directory of Open Access Journals (Sweden)

    Farzad Tahmasbi

    Full Text Available This paper investigates the behaviour of C-shaped and L-shaped angle shear connectors embedded in solid concrete slabs. An effective finite element model is proposed to simulate the push out tests of these shear connectors that encompass nonlinear material behaviour, large displacement and damage plasticity. The finite element models are validated against test results. Parametric studies using this nonlinear model are performed to investigate the variations in concrete strength and connector dimensions. The finite element analyses also confirm the test results that increasing the length of shear connector increases their shear strength proportionately. It is observed that the maximum stress in L-shaped angle connectors takes place in the weld attachment to the beam, whereas in the C-shaped angle connectors, it is in the attached leg. The location of maximum concrete compressive damage is rendered in each case. Finally, a new equation for prediction of the shear capacity of C-shaped angle connectors is proposed.

  9. Lateral angle: a method for sexing using the petrous bone

    DEFF Research Database (Denmark)

    Norén, Anna; Lynnerup, Niels; Czarnetzki, Alfred

    2005-01-01

    We report on the results of applying the so-called lateral angle method for sex determination on skeletal remains. The lateral angle denotes the angle of the internal auditory canal in relation to the medial surface of the petrous part of the temporal bone. The method involves making a small cast...... and females (mean angle size of males, 39.3 degrees ; mean angle size of females, 48.2 degrees ; P lateral angle method against an archaeological skeletal...... sample. True sex was not known for this sample; instead, sexing had been carried out by assessing pelvic and cranial morphology in independent trials. We found a higher concordance between the lateral angle and "pelvic" sex than for lateral angle and "cranial" sex. Finally, we note that subadult sexing...

  10. Measurement of Angle Kappa Using Ultrasound Biomicroscopy and Corneal Topography.

    Science.gov (United States)

    Yeo, Joon Hyung; Moon, Nam Ju; Lee, Jeong Kyu

    2017-06-01

    To introduce a new convenient and accurate method to measure the angle kappa using ultrasound biomicroscopy (UBM) and corneal topography. Data from 42 eyes (13 males and 29 females) were analyzed in this study. The angle kappa was measured using Orbscan II and calculated with UBM and corneal topography. The angle kappa of the dominant eye was compared with measurements by Orbscan II. The mean patient age was 36.4 ± 13.8 years. The average angle kappa measured by Orbscan II was 3.98° ± 1.12°, while the average angle kappa calculated with UBM and corneal topography was 3.19° ± 1.15°. The difference in angle kappa measured by the two methods was statistically significant (p topography to calculate the angle kappa. This method is convenient to use and allows for measurement of the angle kappa without an expensive device. © 2017 The Korean Ophthalmological Society

  11. Apparatus and method for variable angle slant hole collimator

    Science.gov (United States)

    Lee, Seung Joon; Kross, Brian J.; McKisson, John E.

    2017-07-18

    A variable angle slant hole (VASH) collimator for providing collimation of high energy photons such as gamma rays during radiological imaging of humans. The VASH collimator includes a stack of multiple collimator leaves and a means of quickly aligning each leaf to provide various projection angles. Rather than rotate the detector around the subject, the VASH collimator enables the detector to remain stationary while the projection angle of the collimator is varied for tomographic acquisition. High collimator efficiency is achieved by maintaining the leaves in accurate alignment through the various projection angles. Individual leaves include unique angled cuts to maintain a precise target collimation angle. Matching wedge blocks driven by two actuators with twin-lead screws accurately position each leaf in the stack resulting in the precise target collimation angle. A computer interface with the actuators enables precise control of the projection angle of the collimator.

  12. The accuracy of the radiographic method in root canal length measurement

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Eun Young; Park, Chang Seo [Dept. of Dental Radiology, College of Dentistry, Yonsei University, Seoul (Korea, Republic of)

    1998-08-15

    For the successful endodontic treatment, root canal should be cleaned thoroughly by accurate mechanical and chemical canal preparation and sealed completely with canal filling material without damaging the periapical tissues. The accuracy of the root canal length measurement is a prerequisite for the success of the endodontic treatment, and the root canal length is often determined by the standard periapical radiographs and digital tactile sense. In this study, the accuracy and the clinical usefulness of Digora, an intraoral digital imaging processor and the conventional standard radiographs were compared by measuring the length from the top of the file to the root apex. 30 single rooted premolars were invested in a uniformly sized blocks and No.25 K-file was inserted into and fixed in each canal. Each block was placed in equal distance and position to satisfy the principle of the bisecting angle and paralleling techniques and Digora system's image and standard periapical radiographs were taken. Each radiograph was examined by 3 different observers by measuring the length from top of the file to the root apex and each data was compared and analyzed. The results were as follows; 1. In the bisecting angle technique, the average difference between the Digora system and standard periapical radiograph was 0.002 mm and the standard deviation was 0.341 mm which showed no statistically significant difference between the two systems (p>0.05). Also, in the paralleling technique, the average difference between these two system was 0.007 mm and the standard deviation was 0.323 mm which showed no statistically significant difference between the two systems (p>0.05). 2. In Digora system, the average difference between the bisecting angle and paralleling technique was -0.336 mm and the standard deviation was 0.472 mm which showed a statistically significant difference between the two techniques (p<0.05). Also, 3. In Digora system and the standard periapical radiographs

  13. The impact of inlet angle and outlet angle of guide vane on pump in reversal based hydraulic turbine performance

    International Nuclear Information System (INIS)

    Shi, F X; Yang, J H; Wang, X H; Zhang, R H; Li, C E

    2012-01-01

    In this paper, in order to research the impact of inlet angle and outlet angle of guide vane on hydraulic turbine performance, a centrifugal pump in reversal is adopted as turbine. A numerical simulation method is adopted for researching outer performance and flow field of turbine. The results show: inlet angle has a crucial role to turbine, to the same flow, there is a noticeable decline for the efficiency and head of turbine with the inlet angle increases. At the best efficiency point(EFP),to a same inlet angle, when the inlet angle greater than inlet angle, velocity circulation in guide vane outlet decreases, which lead the efficiency of turbine to reduce, Contrarily, the efficiency rises. With the increase of inlet angle and outlet angle, the EFP moves to the big flow area and the uniformity of pressure distribution becomes worse. The paper indicates that the inlet angle and outlet angle have great impact on the turbine performance, and the best combination exists for the inlet angle and outlet angle of the guide vane.

  14. Paddle Angle and Ball Spin in Table Tennis

    Directory of Open Access Journals (Sweden)

    Binvant Broca

    2017-01-01

    Full Text Available The relationship between the impact angle of a table tennis ball with respect to the paddle and angular velocity of the ball leaving the paddle was investigated. A table tennis ball was dropped onto a paddle oriented at impact angles ranging from 10° to 80°. It was found that the sine of the impact angle is proportional to the angular velocity of the ball as it leaves the paddle for all impact angles tested.

  15. Cluster headache or narrow angle glaucoma?

    Directory of Open Access Journals (Sweden)

    Prasad Palimar

    1991-01-01

    Full Text Available A 47 year old man with episodes of attacks of pain, redness and mild blurring of vision was investigated for narrow angle glaucoma in view of shallow anterior chambers and a cupped optic disc. The history was reviewed following a spontaneous attack in hospital, which had features other than acute glaucoma. A diagnosis of cluster headache was made on the basis of tests. Cluster headache has been defined as unilateral intense pain, involving the eye and head on one side, usually associated with flushing, nasal congestion and lacrimation; the attacks recurring one or more times daily and lasting 20 - 120 minutes. Such attacks commonly continue for weeks or months and are separated by an asymptomatic period of months to years. This episodic nature, together with unilaterality and tendency to occur at night, closely mimics narrow angle glaucoma. Further, if patients have shallow anterior chambers and disc cupping, the differentiation becomes more difficult yet critical. Resource to provocative tests is often the only answer as the following case report demonstrates.

  16. Metasurface Enabled Wide-Angle Fourier Lens.

    Science.gov (United States)

    Liu, Wenwei; Li, Zhancheng; Cheng, Hua; Tang, Chengchun; Li, Junjie; Zhang, Shuang; Chen, Shuqi; Tian, Jianguo

    2018-04-19

    Fourier optics, the principle of using Fourier transformation to understand the functionalities of optical elements, lies at the heart of modern optics, and it has been widely applied to optical information processing, imaging, holography, etc. While a simple thin lens is capable of resolving Fourier components of an arbitrary optical wavefront, its operation is limited to near normal light incidence, i.e., the paraxial approximation, which puts a severe constraint on the resolvable Fourier domain. As a result, high-order Fourier components are lost, resulting in extinction of high-resolution information of an image. Other high numerical aperture Fourier lenses usually suffer from the bulky size and costly designs. Here, a dielectric metasurface consisting of high-aspect-ratio silicon waveguide array is demonstrated experimentally, which is capable of performing 1D Fourier transform for a large incident angle range and a broad operating bandwidth. Thus, the device significantly expands the operational Fourier space, benefitting from the large numerical aperture and negligible angular dispersion at large incident angles. The Fourier metasurface will not only facilitate efficient manipulation of spatial spectrum of free-space optical wavefront, but also be readily integrated into micro-optical platforms due to its compact size. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. A LEGO Mindstorms Brewster angle microscope

    Science.gov (United States)

    Fernsler, Jonathan; Nguyen, Vincent; Wallum, Alison; Benz, Nicholas; Hamlin, Matthew; Pilgram, Jessica; Vanderpoel, Hunter; Lau, Ryan

    2017-09-01

    A Brewster Angle Microscope (BAM) built from a LEGO Mindstorms kit, additional LEGO bricks, and several standard optics components, is described. The BAM was built as part of an undergraduate senior project and was designed, calibrated, and used to image phospholipid, cholesterol, soap, and oil films on the surface of water. A BAM uses p-polarized laser light reflected off a surface at the Brewster angle, which ideally yields zero reflectivity. When a film of different refractive index is added to the surface a small amount of light is reflected, which can be imaged in a microscope camera. Films of only one molecule (approximately 1 nm) thick, a monolayer, can be observed easily in the BAM. The BAM was used in a junior-level Physical Chemistry class to observe phase transitions of a monolayer and the collapse of a monolayer deposited on the water surface in a Langmuir trough. Using a photometric calculation, students observed a change in thickness of a monolayer during a phase transition of 7 Å, which was accurate to within 1 Å of the value determined by more advanced methods. As supplementary material, we provide a detailed manual on how to build the BAM, software to control the BAM and camera, and image processing software.

  18. A superlinear iteration method for calculation of finite length journal bearing's static equilibrium position

    Science.gov (United States)

    Zhou, Wenjie; Wei, Xuesong; Wang, Leqin; Wu, Guangkuan

    2017-05-01

    Solving the static equilibrium position is one of the most important parts of dynamic coefficients calculation and further coupled calculation of rotor system. The main contribution of this study is testing the superlinear iteration convergence method-twofold secant method, for the determination of the static equilibrium position of journal bearing with finite length. Essentially, the Reynolds equation for stable motion is solved by the finite difference method and the inner pressure is obtained by the successive over-relaxation iterative method reinforced by the compound Simpson quadrature formula. The accuracy and efficiency of the twofold secant method are higher in comparison with the secant method and dichotomy. The total number of iterative steps required for the twofold secant method are about one-third of the secant method and less than one-eighth of dichotomy for the same equilibrium position. The calculations for equilibrium position and pressure distribution for different bearing length, clearance and rotating speed were done. In the results, the eccentricity presents linear inverse proportional relationship to the attitude angle. The influence of the bearing length, clearance and bearing radius on the load-carrying capacity was also investigated. The results illustrate that larger bearing length, larger radius and smaller clearance are good for the load-carrying capacity of journal bearing. The application of the twofold secant method can greatly reduce the computational time for calculation of the dynamic coefficients and dynamic characteristics of rotor-bearing system with a journal bearing of finite length.

  19. OPTIMUM COALESCENCE PLATE ARC LENGTH FOR REMOVAL OF OIL DROPLETS FROM WASTEWATERS

    Directory of Open Access Journals (Sweden)

    H. S. ALMAROUF

    2007-12-01

    Full Text Available Aspects on the arc length of coalescence plates of a oil-water separator as determinant factors for removal of oil droplets from wastewaters were investigated. The primary component of the separator consists of a series of concave and convex shaped coalescence plates to form multiple angles plate arrangement for enhancement of oil droplet coalescence onto the plates. Experimental results were obtained using different overflow rates and different arc lengths of coalescence plates, and were statistically evaluated. As a result, a series of mathematical equations pertaining to oil removal efficiencies from wastewaters were formulated. The predicted and observed data were compared, and optimal coalescence plate arc lengths for maximum oil droplets removal from wastewater at different flow rates were determined. It was also found that coalescence plate arc length had a more significant effect on oil removal efficiency at high overflow rate than at low overflow rate, i.e. oil removal efficiency dropped with reducing coalescence plate arc length. It was also concluded that removal efficiency of emulsified oil droplets from wastewater was strongly correlated to the system’s overflow rate and horizontal projection of arc coalescence plate area.

  20. A superlinear iteration method for calculation of finite length journal bearing's static equilibrium position.

    Science.gov (United States)

    Zhou, Wenjie; Wei, Xuesong; Wang, Leqin; Wu, Guangkuan

    2017-05-01

    Solving the static equilibrium position is one of the most important parts of dynamic coefficients calculation and further coupled calculation of rotor system. The main contribution of this study is testing the superlinear iteration convergence method-twofold secant method, for the determination of the static equilibrium position of journal bearing with finite length. Essentially, the Reynolds equation for stable motion is solved by the finite difference method and the inner pressure is obtained by the successive over-relaxation iterative method reinforced by the compound Simpson quadrature formula. The accuracy and efficiency of the twofold secant method are higher in comparison with the secant method and dichotomy. The total number of iterative steps required for the twofold secant method are about one-third of the secant method and less than one-eighth of dichotomy for the same equilibrium position. The calculations for equilibrium position and pressure distribution for different bearing length, clearance and rotating speed were done. In the results, the eccentricity presents linear inverse proportional relationship to the attitude angle. The influence of the bearing length, clearance and bearing radius on the load-carrying capacity was also investigated. The results illustrate that larger bearing length, larger radius and smaller clearance are good for the load-carrying capacity of journal bearing. The application of the twofold secant method can greatly reduce the computational time for calculation of the dynamic coefficients and dynamic characteristics of rotor-bearing system with a journal bearing of finite length.

  1. Walking on inclines: how do desert ants monitor slope and step length

    Directory of Open Access Journals (Sweden)

    Seidl Tobias

    2008-06-01

    Full Text Available Abstract Background During long-distance foraging in almost featureless habitats desert ants of the genus Cataglyphis employ path-integrating mechanisms (vector navigation. This navigational strategy requires an egocentric monitoring of the foraging path by incrementally integrating direction, distance, and inclination of the path. Monitoring the latter two parameters involves idiothetic cues and hence is tightly coupled to the ant's locomotor behavior. Results In a kinematic study of desert ant locomotion performed on differently inclined surfaces we aimed at pinpointing the relevant mechanisms of estimating step length and inclination. In a behavioral experiment with ants foraging on slippery surfaces we broke the otherwise tightly coupled relationship between stepping frequency and step length and examined the animals' ability to monitor distances covered even under those adverse conditions. We show that the ants' locomotor system is not influenced by inclined paths. After removing the effect of speed, slope had only marginal influence on kinematic parameters. Conclusion From the obtained data we infer that the previously proposed monitoring of angles of the thorax-coxa joint is not involved in inclinometry. Due to the tiny variations in cycle period, we also argue that an efference copy of the central pattern generator coding the step length in its output frequency will most likely not suffice for estimating step length and complementing the pedometer. Finally we propose that sensing forces acting on the ant's legs could provide the desired neuronal correlate employed in monitoring inclination and step length.

  2. SU-E-T-446: Group-Sparsity Based Angle Generation Method for Beam Angle Optimization

    International Nuclear Information System (INIS)

    Gao, H

    2015-01-01

    Purpose: This work is to develop the effective algorithm for beam angle optimization (BAO), with the emphasis on enabling further improvement from existing treatment-dependent templates based on clinical knowledge and experience. Methods: The proposed BAO algorithm utilizes a priori beam angle templates as the initial guess, and iteratively generates angular updates for this initial set, namely angle generation method, with improved dose conformality that is quantitatively measured by the objective function. That is, during each iteration, we select “the test angle” in the initial set, and use group-sparsity based fluence map optimization to identify “the candidate angle” for updating “the test angle”, for which all the angles in the initial set except “the test angle”, namely “the fixed set”, are set free, i.e., with no group-sparsity penalty, and the rest of angles including “the test angle” during this iteration are in “the working set”. And then “the candidate angle” is selected with the smallest objective function value from the angles in “the working set” with locally maximal group sparsity, and replaces “the test angle” if “the fixed set” with “the candidate angle” has a smaller objective function value by solving the standard fluence map optimization (with no group-sparsity regularization). Similarly other angles in the initial set are in turn selected as “the test angle” for angular updates and this chain of updates is iterated until no further new angular update is identified for a full loop. Results: The tests using the MGH public prostate dataset demonstrated the effectiveness of the proposed BAO algorithm. For example, the optimized angular set from the proposed BAO algorithm was better the MGH template. Conclusion: A new BAO algorithm is proposed based on the angle generation method via group sparsity, with improved dose conformality from the given template. Hao Gao was partially supported by the

  3. Influence of Contact Angle Boundary Condition on CFD Simulation of T-Junction

    Science.gov (United States)

    Arias, S.; Montlaur, A.

    2018-03-01

    In this work, we study the influence of the contact angle boundary condition on 3D CFD simulations of the bubble generation process occurring in a capillary T-junction. Numerical simulations have been performed with the commercial Computational Fluid Dynamics solver ANSYS Fluent v15.0.7. Experimental results serve as a reference to validate numerical results for four independent parameters: the bubble generation frequency, volume, velocity and length. CFD simulations accurately reproduce experimental results both from qualitative and quantitative points of view. Numerical results are very sensitive to the gas-liquid-wall contact angle boundary conditions, confirming that this is a fundamental parameter to obtain accurate CFD results for simulations of this kind of problems.

  4. Growth characteristics of inclined columns produced by Glancing Angle Deposition (GLAD) and colloidal lithography

    DEFF Research Database (Denmark)

    Foss, Morten; Besenbacher, Flemming; Sutherland, Duncan S

    2011-01-01

    Nanocolumns were produced by performing Glancing Angle Deposition (GLAD) onto self-assembled template arrays consisting of platinum coated polystyrene spheres. By varying the angle of incidence (θ = 35°, 10° and 5°) and the deposited surface mass density it was possible to control the shape of th...... and shadowing effects. A detailed understanding of the underlying processes governing the nanocolumn growth might be utilized in the design of new functional nanomaterials....... retrieved from the length and width increment as function of the deposited surface mass density decreased from 1.06 to 0.46 and 0.71 to 0.09, respectively, as θ changed from 35° to 5°. The changes in the power law exponents indicate that the growth of the nano-columns is influenced by both surface diffusion...

  5. Small-angle neutron scattering investigations of nanocrystalline alloy chips obtained by machining

    Directory of Open Access Journals (Sweden)

    Elwyn Rebello

    2014-12-01

    Full Text Available Ultrafine-grained (UFG materials exhibit significantly enhanced mechanical properties. This has brought renewed attention on the use of large strain or severe plastic deformation as a means for achieving microstructural refinement in metals and alloys. Large plastic strains imposed in a machine chip result in significant microstructural refinement, including the creation of UFG and nanocrystalline materials. It looks to be an economical route for realizing nanocrystalline materials. In the present study, small-angle neutron scattering (SANS was employed to investigate the modifications in the microstructure of the chips produced via machining. Double crystal-based medium resolution SANS instrument has been used for this purpose. Significant scattering intensity at small enough angles reveals the presence of mesoscopic density fluctuations produced because of the machining. Atomic force microscopy images also corroborate the existence of such small length scale density fluctuations.

  6. Interpretation of small-angle scattering of block copolymer/nanoparticle blends using random phase approximation.

    Science.gov (United States)

    Hakem, I F; Benmouna, A; Benmouna, R; Ferebee, R; Benmouna, M; Bockstaller, M R

    2014-06-01

    The scattering characteristics of block copolymer (BCP)/nanoparticle (NP) blend systems are analyzed in the weak segregation limit using random phase approximation (RPA). The scattering function is established and shown to adequately capture reported data of small-angle neutron scattering in poly(norbornene-b -d-norbornene dicarboxylic acid)/ Fe3O4 nanoparticle blend systems over the entire small-angle range for a variety of BCP and NP compositions. Besides predicting the relevant length scales of microstructure formation, the RPA analysis reveals the increase of segregation in the BCP system upon NP addition. The insight into the thermodynamics of microstructure formation in BCP/NP blend systems that is provided by the RPA analysis should be a valuable asset for the design of BCP-based microstructured hybrid materials with predetermined structure and properties.

  7. Small-angle neutron scattering in materials science: Recent practical applications

    Science.gov (United States)

    Melnichenko, Yuri B.; Wignall, George D.

    2007-07-01

    Modern materials science and engineering relies increasingly on detailed knowledge of the structure and interactions in "soft" and "hard" materials, but there have been surprisingly few microscopic techniques for probing the structures of bulk samples of these substances. Small-angle neutron scattering (SANS) was first recognized in Europe as a major technique for this purpose and, over the past several decades, has been a growth area in both academic and industrial materials research to provide structural information on length scales ˜10-1000Å (or 1-100nm). The technique of ultrahigh resolution small-angle neutron scattering (USANS) raises the upper resolution limit for structural studies by more than two orders of magnitude and (up to ˜30μm) and hence overlaps with light scattering and microscopy. This review illustrates the ongoing vitality of SANS and USANS in materials research via a range of current practical applications from both soft and hard matter nanostructured systems.

  8. An analysis of oblique angle stimulated cherenkov radiation with some experimental results

    International Nuclear Information System (INIS)

    Piestrup, M.A.

    1983-01-01

    This paper considers the possible amplification in a dielectric medium of a plane wave intersected by an electron beam at the Cherenkov angle. An oscillator is designed in which a Fabry-Perot resonator's axis is placed at this angle. The gain is found to be inversely proportional to the wavelength, suggesting the possibility of a vacuum ultraviolet or soft X-ray laser. The randomization of the phase coherence between the wave and the electrons due to multiple scattering of the electrons by the atoms of the dielectric is minimized by limiting the length of interaction, and increasing the electron beam energy. Early unpublished experiments are given in which quartz resonators were placed in the Mark III Linear Accelerator's electron beam at Stanford University. From this, other subsequent experimental work, and the theory derived here, two devices are considered which utilize gas as a dielectric instead of a solid

  9. Evaluation of the normal calcaneal angles in Egyptian population

    African Journals Online (AJOL)

    Fahmy Anwar Shoukry

    2012-02-01

    Feb 1, 2012 ... ison of the angles according to the side), independent t-test was used to compare the angles according to the sex), distribution of the angles within different age groups was compared with one way analysis of variance (ANOVA) test. The level of sig- nificance was set at p < 0.05, and compared the results of.

  10. Objectifying the Adjacent and Opposite Angles: A Cultural Historical Analysis

    Science.gov (United States)

    Daher, Wajeeh; Musallam, Nadera

    2018-01-01

    The angle topic is central to the development of geometric knowledge. Two of the basic concepts associated with this topic are the adjacent and opposite angles. It is the goal of the present study to analyze, based on the cultural historical semiotics framework, how high-achieving seventh grade students objectify the adjacent and opposite angles'…

  11. Small angle neutron scattering from glassy SiO2

    International Nuclear Information System (INIS)

    Spooner, S.; Hastings, J.B.

    1976-01-01

    The present investigation of neutron scattering from glassy silica was undertaken to resolve whether the small angle scattering observed by Renninger and Uhlmann could also be seen in the bulk samples typically used in neutron-scattering experiments. Within the rather large error bars of this experiment no small angle scattering increase at small angles could be seen. (Auth.)

  12. Goniodysgenesis in familial primary open-angle glaucoma

    NARCIS (Netherlands)

    Verbraak, F. D.; vd Berg, W.; Delleman, J. W.; Greve, E. L.

    1994-01-01

    Results of a pilot study to evaluate goniodysgenesis as a cause of familial open-angle glaucoma are reported. Patients with a familial high tension open-angle glaucoma and a goniodysgenetic chamber angle (n = 11), a number of their relatives with glaucoma (n = 12), and their relatives without

  13. Cubic Equations and the Ideal Trisection of the Arbitrary Angle

    Science.gov (United States)

    Farnsworth, Marion B.

    2006-01-01

    In the year 1837 mathematical proof was set forth authoritatively stating that it is impossible to trisect an arbitrary angle with a compass and an unmarked straightedge in the classical sense. The famous proof depends on an incompatible cubic equation having the cosine of an angle of 60 and the cube of the cosine of one-third of an angle of 60 as…

  14. Fostering Students' Development of the Concept of Angles Using Technology

    Science.gov (United States)

    Richardson, Sue Ellen; Koyunkaya, Melike Yigit

    2017-01-01

    We have used "GeoGebra," a dynamic geometry software environment, to explore how Year 4 students understand definitions of angles. Seven students defined angle and then completed several activities adapted for the dynamic environment. Afterward, students again shared their definitions of angles. We found that even a short investigation…

  15. 47 CFR 25.205 - Minimum angle of antenna elevation.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Minimum angle of antenna elevation. 25.205... SATELLITE COMMUNICATIONS Technical Standards § 25.205 Minimum angle of antenna elevation. (a) Earth station antennas shall not normally be authorized for transmission at angles less than 5° measured from the...

  16. Generation of Length Distribution, Length Diagram, Fibrogram, and Statistical Characteristics by Weight of Cotton Blends

    Directory of Open Access Journals (Sweden)

    B. Azzouz

    2007-01-01

    Full Text Available The textile fibre mixture as a multicomponent blend of variable fibres imposes regarding the proper method to predict the characteristics of the final blend. The length diagram and the fibrogram of cotton are generated. Then the length distribution, the length diagram, and the fibrogram of a blend of different categories of cotton are determined. The length distributions by weight of five different categories of cotton (Egyptian, USA (Pima, Brazilian, USA (Upland, and Uzbekistani are measured by AFIS. From these distributions, the length distribution, the length diagram, and the fibrogram by weight of four binary blends are expressed. The length parameters of these cotton blends are calculated and their variations are plotted against the mass fraction x of one component in the blend .These calculated parameters are compared to those of real blends. Finally, the selection of the optimal blends using the linear programming method, based on the hypothesis that the cotton blend parameters vary linearly in function of the components rations, is proved insufficient.

  17. Length-scale dependent phonon interactions

    CERN Document Server

    Srivastava, Gyaneshwar

    2014-01-01

    This book presents  a comprehensive description of phonons and their interactions in systems with different dimensions and length scales. Internationally-recognized leaders describe theories and measurements of phonon interactions  in relation to the design of materials with exotic properties such as metamaterials, nano-mechanical systems, next-generation electronic, photonic, and acoustic devices, energy harvesting, optical information storage, and applications of phonon lasers in a variety of fields. The emergence of techniques for control of semiconductor properties and geometry has enabled engineers to design structures in which functionality is derived from controlling electron behavior. As manufacturing techniques have greatly expanded the list of available materials and the range of attainable length scales, similar opportunities now exist for designing devices whose functionality is derived from controlling phonon behavior. However, progress in this area is hampered by gaps in our knowledge of phono...

  18. Distance and Cable Length Measurement System

    Science.gov (United States)

    Hernández, Sergio Elias; Acosta, Leopoldo; Toledo, Jonay

    2009-01-01

    A simple, economic and successful design for distance and cable length detection is presented. The measurement system is based on the continuous repetition of a pulse that endlessly travels along the distance to be detected. There is a pulse repeater at both ends of the distance or cable to be measured. The endless repetition of the pulse generates a frequency that varies almost inversely with the distance to be measured. The resolution and distance or cable length range could be adjusted by varying the repetition time delay introduced at both ends and the measurement time. With this design a distance can be measured with centimeter resolution using electronic system with microsecond resolution, simplifying classical time of flight designs which require electronics with picosecond resolution. This design was also applied to position measurement. PMID:22303169

  19. Separation of pathogenic bacteria by chain length.

    Science.gov (United States)

    Beech, Jason P; Ho, Bao Dang; Garriss, Geneviève; Oliveira, Vitor; Henriques-Normark, Birgitta; Tegenfeldt, Jonas O

    2018-02-13

    Using Deterministic Lateral Displacement devices optimized for sensitivity to particle length, we separate subpopulations of bacteria depending on known properties that affect their capability to cause disease (virulence). For the human bacterial pathogen Streptococcus pneumoniae, bacterial chain length and the presence of a capsule are known virulence factors contributing to its ability to cause severe disease. Separation of cultured pneumococci into subpopulations based on morphological type (single cocci, diplococci and chains) will enable more detailed studies of the role they play in virulence. Moreover, we present separation of mixed populations of almost genetically identical encapsulated and non-encapsulated pneumococcal strains in our device. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  20. Electron attenuation lengths in fullerene and fullerides

    International Nuclear Information System (INIS)

    Li Hongnian; Wang Xiaoxiong; Ding Wangfeng

    2006-01-01

    Using X-ray photoemission measurements, we have determined the attenuation length of C 1s photoelectrons in C 60 film to be 21.5 A with the incident photon energy of Mg Kα radiation. The inelastic mean free path calculated with the TPP-2M algorithm coincides fairly well with the experimentally determined attenuation length, indicating the validity of the algorithm to fullerene and fullerides. The inelastic mean free paths for some fullerides, i.e. K 3 C 60 , K 6 C 60 , Ba 4 C 60 , Sm 2.75 C 60 and Sm 6 C 60 are calculated to help the quantitative analyses of the photoemission spectra for these compounds

  1. Correlation between architectural variables and torque in the erector spinae muscle during maximal isometric contraction.

    Science.gov (United States)

    Cuesta-Vargas, Antonio; González-Sánchez, Manuel

    2014-01-01

    This study analysed whether a significant relationship exists between the torque and muscle thickness and pennation angle of the erector spinae muscle during a maximal isometric lumbar extension with the lumbar spine in neutral position. This was a cross-sectional study in which 46 healthy adults performed three repetitions for 5 s of maximal isometric lumbar extension with rests of 90 s. During the lumbar extensions, bilateral ultrasound images of the erector spinae muscle (to measure pennation angle and muscle thickness) and torque were acquired. Reliability test analysis calculating the internal consistency (Cronbach's alpha) of the measure, correlation between pennation angle, muscle thickness and torque extensions were examined. Through a linear regression the contribution of each independent variable (muscle thickness and pennation angle) to the variation of the dependent variable (torque) was calculated. The results of the reliability test were: 0.976-0.979 (pennation angle), 0.980-0.980 (muscle thickness) and 0.994 (torque). The results show that pennation angle and muscle thickness were significantly related to each other with a range between 0.295 and 0.762. In addition, multiple regression analysis showed that the two variables considered in this study explained 68% of the variance in the torque. Pennation angle and muscle thickness have a moderate impact on the variance exerted on the torque during a maximal isometric lumbar extension with the lumbar spine in neutral position.

  2. Measuring the orbit length of the Tevatron

    International Nuclear Information System (INIS)

    Kerns, C.; Kerns, Q.; Miller, H.

    1985-06-01

    The orbit length in the Tevatron was measured when coasting beam was first obtained. The method was time-of-flight, using a vernier phase comparison between beam pickup signals and a synthesizer sine wave. Some effort was spent making a stable phase detector so that it would not be a limiting factor. The results exhibited a repeatability of a few Hz at 53 MHz, corresponding to a mean radius measurement to 0.1 mm. 5 refs., 4 figs

  3. Measure it! fun with length and distance

    CERN Document Server

    First, Rachel

    2016-01-01

    Make math fun with Measure It! Fun photographs, colorful graphics, and simple text are used to teach young readers basic math concepts. From Metric System to Standard System this book will help kids develop the skills they need. A simple activity at the end of the book encourages kids to put length and distance to use! Aligned to Common Core standards and correlated to state standards. Sandcastle is an imprint of Abdo Publishing, a division of ABDO.

  4. Minimum Description Length Shape and Appearance Models

    DEFF Research Database (Denmark)

    Thodberg, Hans Henrik

    2003-01-01

    The Minimum Description Length (MDL) approach to shape modelling is reviewed. It solves the point correspondence problem of selecting points on shapes defined as curves so that the points correspond across a data set. An efficient numerical implementation is presented and made available as open s...... source Matlab code. The problems with the early MDL approaches are discussed. Finally the MDL approach is extended to an MDL Appearance Model, which is proposed as a means to perform unsupervised image segmentation....

  5. Asymptotic safety, emergence and minimal length

    International Nuclear Information System (INIS)

    Percacci, Roberto; Vacca, Gian Paolo

    2010-01-01

    There seems to be a common prejudice that asymptotic safety is either incompatible with, or at best unrelated to, the other topics in the title. This is not the case. In fact, we show that (1) the existence of a fixed point with suitable properties is a promising way of deriving emergent properties of gravity, and (2) there is a sense in which asymptotic safety implies a minimal length. In doing so we also discuss possible signatures of asymptotic safety in scattering experiments.

  6. Step Length Estimation Using Handheld Inertial Sensors

    Directory of Open Access Journals (Sweden)

    Gérard Lachapelle

    2012-06-01

    Full Text Available In this paper a novel step length model using a handheld Micro Electrical Mechanical System (MEMS is presented. It combines the user’s step frequency and height with a set of three parameters for estimating step length. The model has been developed and trained using 12 different subjects: six men and six women. For reliable estimation of the step frequency with a handheld device, the frequency content of the handheld sensor’s signal is extracted by applying the Short Time Fourier Transform (STFT independently from the step detection process. The relationship between step and hand frequencies is analyzed for different hand’s motions and sensor carrying modes. For this purpose, the frequency content of synchronized signals collected with two sensors placed in the hand and on the foot of a pedestrian has been extracted. Performance of the proposed step length model is assessed with several field tests involving 10 test subjects different from the above 12. The percentages of error over the travelled distance using universal parameters and a set of parameters calibrated for each subject are compared. The fitted solutions show an error between 2.5 and 5% of the travelled distance, which is comparable with that achieved by models proposed in the literature for body fixed sensors only.

  7. The Effective Coherence Length in Anisotropic Superconductors

    International Nuclear Information System (INIS)

    Polturak, E.; Koren, G.; Nesher, O

    1999-01-01

    If electrons are transmitted from a normal conductor(N) into a superconductor(S), common wisdom has it that the electrons are converted into Cooper pairs within a coherence length from the interface. This is true in conventional superconductors with an isotropic order parameter. We have established experimentally that the situation is rather different in high Tc superconductors having an anisotropic order parameter. We used epitaxial thin film S/N bilayers having different interface orientations in order to inject carriers from S into N along different directions. The distance to which these carriers penetrate were determined through their effect on the Tc of the bilayers. We found that the effective coherence length is 20A only along the a or b directions, while in other directions we find a length of 250dr20A out of plane, and an even larger value for in-plane, off high symmetry directions. These observations can be explained using the Blonder-Tinkham-Klapwijk model adapted to anisotropic superconductivity. Several implications of our results on outstanding problems with high Tc junctions will be discussed

  8. Development of the Heated Length Correction Factor

    International Nuclear Information System (INIS)

    Park, Ho-Young; Kim, Kang-Hoon; Nahm, Kee-Yil; Jung, Yil-Sup; Park, Eung-Jun

    2008-01-01

    The Critical Heat Flux (CHF) on a nuclear fuel is defined by the function of flow channel geometry and flow condition. According to the selection of the explanatory variable, there are three hypotheses to explain CHF at uniformly heated vertical rod (inlet condition hypothesis, exit condition hypothesis, local condition hypothesis). For inlet condition hypothesis, CHF is characterized by function of system pressure, rod diameter, rod length, mass flow and inlet subcooling. For exit condition hypothesis, exit quality substitutes for inlet subcooling. Generally the heated length effect on CHF in exit condition hypothesis is smaller than that of other variables. Heated length is usually excluded in local condition hypothesis to describe the CHF with only local fluid conditions. Most of commercial plants currently use the empirical CHF correlation based on local condition hypothesis. Empirical CHF correlation is developed by the method of fitting the selected sensitive local variables to CHF test data using the multiple non-linear regression. Because this kind of method can not explain physical meaning, it is difficult to reflect the proper effect of complex geometry. So the recent CHF correlation development strategy of nuclear fuel vendor is making the basic CHF correlation which consists of basic flow variables (local fluid conditions) at first, and then the geometrical correction factors are compensated additionally. Because the functional forms of correction factors are determined from the independent test data which represent the corresponding geometry separately, it can be applied to other CHF correlation directly only with minor coefficient modification

  9. Determining multiple length scales in rocks

    Science.gov (United States)

    Song, Yi-Qiao; Ryu, Seungoh; Sen, Pabitra N.

    2000-07-01

    Carbonate reservoirs in the Middle East are believed to contain about half of the world's oil. The processes of sedimentation and diagenesis produce in carbonate rocks microporous grains and a wide range of pore sizes, resulting in a complex spatial distribution of pores and pore connectivity. This heterogeneity makes it difficult to determine by conventional techniques the characteristic pore-length scales, which control fluid transport properties. Here we present a bulk-measurement technique that is non-destructive and capable of extracting multiple length scales from carbonate rocks. The technique uses nuclear magnetic resonance to exploit the spatially varying magnetic field inside the pore space itself-a `fingerprint' of the pore structure. We found three primary length scales (1-100µm) in the Middle-East carbonate rocks and determined that the pores are well connected and spatially mixed. Such information is critical for reliably estimating the amount of capillary-bound water in the rock, which is important for efficient oil production. This method might also be used to complement other techniques for the study of shaly sand reservoirs and compartmentalization in cells and tissues.

  10. Short Rayleigh length free electron lasers

    Directory of Open Access Journals (Sweden)

    W. B. Colson

    2006-03-01

    Full Text Available Conventional free electron laser (FEL oscillators minimize the optical mode volume around the electron beam in the undulator by making the resonator Rayleigh length about one third to one half of the undulator length. This maximizes gain and beam-mode coupling. In compact configurations of high-power infrared FELs or moderate power UV FELs, the resulting optical intensity can damage the resonator mirrors. To increase the spot size and thereby reduce the optical intensity at the mirrors below the damage threshold, a shorter Rayleigh length can be used, but the FEL interaction is significantly altered. We model this interaction using a coordinate system that expands with the rapidly diffracting optical mode from the ends of the undulator to the mirrors. Simulations show that the interaction of the strongly focused optical mode with a narrow electron beam inside the undulator distorts the optical wave front so it is no longer in the fundamental Gaussian mode. The simulations are used to study how mode distortion affects the single-pass gain in weak fields, and the steady-state extraction in strong fields.

  11. Structural adaptations of rat lateral gastrocnemius muscle-tendon complex to a chronic stretching program and their quantification based on ultrasound biomicroscopy and optical microscopic images.

    Science.gov (United States)

    Peixinho, Carolina Carneiro; Martins, Natália Santos Fonseca; de Oliveira, Liliam Fernandes; Machado, João Carlos

    2014-01-01

    A chronic regimen of flexibility training can increase range of motion, with the increase mechanisms believed to be a change in the muscle material properties or in the neural components associated with this type of training. This study followed chronic structural adaptations of lateral gastrocnemius muscle of rats submitted to stretching training (3 times a week during 8weeks), based on muscle architecture measurements including pennation angle, muscle thickness and tendon length obtained from ultrasound biomicroscopic images, in vivo. Fiber length and sarcomere number per 100μm were determined in 3 fibers of each muscle (ex vivo and in vitro, respectively), using conventional optical microscopy. Stretching training resulted in a significant pennation angle reduction of the stretched leg after 12 sessions (25%, P=0.002 to 0.024). Muscle thickness and tendon length presented no significant changes. Fiber length presented a significant increase for the stretched leg (8.5%, P=0.00006), with the simultaneous increase in sarcomere length (5%, P=0.041) since the stretched muscles presented less sarcomeres per 100μm. A stretching protocol with characteristics similar to those applied in humans was sufficient to modify muscle architecture of rats with absence of a sarcomerogenesis process. The results indicate that structural adaptations take place in skeletal muscle tissue submitted to moderate-intensity stretching training. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Using Digital Technology to See Angles from Different Angles. Part 1: Corners

    Science.gov (United States)

    Host, Erin; Baynham, Emily; McMaster, Heather

    2014-01-01

    In Part 1 of their article, Erin Host, Emily Baynham and Heather McMaster use a combination of digital technology and concrete materials to explore the concept of "corners". They provide a practical, easy to follow sequence of activities that builds on students' understandings. [For "Using Digital Technology to See Angles from…

  13. Scattering angle-based filtering via extension in velocity

    KAUST Repository

    Kazei, Vladimir

    2016-09-06

    The scattering angle between the source and receiver wavefields can be utilized in full-waveform inversion (FWI) and in reverse-time migration (RTM) for regularization and quality control or to remove low frequency artifacts. The access to the scattering angle information is costly as the relation between local image features and scattering angles has non-stationary nature. For the purpose of a more efficient scattering angle information extraction, we develop techniques that utilize the simplicity of the scattering angle based filters for constantvelocity background models. We split the background velocity model into several domains with different velocity ranges, generating an

  14. Spondylolysis and the sacro-horizontal angle in athletes

    International Nuclear Information System (INIS)

    Swaerd, L.; Hellstroem, M.; Jacobsson, B.; Peterson, L.; Sahlgrenska Sjukhuset, Goeteborg; King Faisal Specialist Hospital and Research Centre, Riyadh

    1989-01-01

    The frequency of spondylolysis and the relationship between spondylolysis and the sacro-horizontal angle in 143 athletes and 30 non-athletes is reported. Athletes had a larger sacro-horizontal angle than non-athletes. The sacro-horizontal angle was larger in athletes with spondylolysis as compared with those without. An increased incidence of spondylolysis with an increased angle was demonstrated. It is suggested that an increased sacro-horizontal angle may predispose to spondylolysis, especially in combination with the high mechanical loads sustained in certain sports. (orig.)

  15. Spondylolysis and the sacro-horizontal angle in athletes

    Energy Technology Data Exchange (ETDEWEB)

    Swaerd, L.; Hellstroem, M.; Jacobsson, B.; Peterson, L. (Oestra Sjukhuset, Goeteborg (Sweden). Dept. of Orthopaedics; Sahlgrenska Sjukhuset, Goeteborg (Sweden). Dept. of Diagnostic Radiology; King Faisal Specialist Hospital and Research Centre, Riyadh (Saudi Arabia). Dept. of Radiology)

    The frequency of spondylolysis and the relationship between spondylolysis and the sacro-horizontal angle in 143 athletes and 30 non-athletes is reported. Athletes had a larger sacro-horizontal angle than non-athletes. The sacro-horizontal angle was larger in athletes with spondylolysis as compared with those without. An increased incidence of spondylolysis with an increased angle was demonstrated. It is suggested that an increased sacro-horizontal angle may predispose to spondylolysis, especially in combination with the high mechanical loads sustained in certain sports. (orig.).

  16. Use of Small Angle Neutron Scattering to Study Various Properties of Wool and Mohair Fibres

    Science.gov (United States)

    Franklyn, C. B.; Török, Gy.

    2011-12-01

    To maintain a competitive edge in the wool and mohair industry, a detailed knowledge and understanding of the properties of wool fibres is essential. Standard techniques are used to determine fibre diameter, length and strength; however, properties such as hydroscopicity, lustre and changes in fibre structure following chemical or mechanical treatment are not so well understood. The unique capabilities of small angle neutron scattering to study changes in the supermolecular structure of wool fibres, particularly at the level of the microfibril-matrix complex, have been used to provide previously unknown features of the fibres. The results of these studies are presented.

  17. Observation of magnetic flux line structures in superconductors by small-angle neutron diffraction

    International Nuclear Information System (INIS)

    Forgan, E.M.; Cubitt, R.; Lee, S.L.; Paul, D.McK.; Mook, H.A.; Yethiraj, McK.; Bishop, D.A.; Gammel, P.L.; Kleiman, R.N.

    1993-01-01

    We describe the recent uses of the technique of small-angle neutron diffraction to investigate flux-line structures within the bulk of superconductors in the mixed state. Despite the small signal in superconductors with a long penetration depth, useful results have been obtained in both High-T c and heavy-fermion superconductors. These can give information about the perfection of the flux lattice, the values of characteristics lengths, the influence of crystal anisotropy and defects on the flux lattice structure and orientation, and on temperature and flux lattice melting effects. (orig.)

  18. Small-angle neutron scattering from multilamellar lipid bilayers: Theory, model, and experiment

    DEFF Research Database (Denmark)

    Lemmich, Jesper; Mortensen, Kell; Ipsen, John Hjorth

    1996-01-01

    Small-angle neutron scattering data obtained from fully hydrated, multilamellar phospholipid bilayers with deuterated acyl chains of different length are presented and analyzed within a paracrystalline theory and a geometric model that permit the bilayer structure to be determined under conditions...... where the lamellar layers are coupled and fluctuating. This theory provides structural information in the region of the solid-fluid bilayer phase transition without invoking the usual decoupling of the scattering intensity function into form and structure factors. Results are presented as a function...

  19. Sinusoidal Order Estimation Using Angles between Subspaces

    Directory of Open Access Journals (Sweden)

    Søren Holdt Jensen

    2009-01-01

    Full Text Available We consider the problem of determining the order of a parametric model from a noisy signal based on the geometry of the space. More specifically, we do this using the nontrivial angles between the candidate signal subspace model and the noise subspace. The proposed principle is closely related to the subspace orthogonality property known from the MUSIC algorithm, and we study its properties and compare it to other related measures. For the problem of estimating the number of complex sinusoids in white noise, a computationally efficient implementation exists, and this problem is therefore considered in detail. In computer simulations, we compare the proposed method to various well-known methods for order estimation. These show that the proposed method outperforms the other previously published subspace methods and that it is more robust to the noise being colored than the previously published methods.

  20. Angle-resolved photoemission extended fine structure

    International Nuclear Information System (INIS)

    Barton, J.J.

    1985-03-01

    Measurements of the Angle-Resolved Photoemission Extended Fine Structure (ARPEFS) from the S(1s) core level of a c(2 x 2)S/Ni(001) are analyzed to determine the spacing between the S overlayer and the first and second Ni layers. ARPEFS is a type of photoelectron diffraction measurement in which the photoelectron kinetic energy is swept typically from 100 to 600 eV. By using this wide range of intermediate energies we add high precision and theoretical simplification to the advantages of the photoelectron diffraction technique for determining surface structures. We report developments in the theory of photoelectron scattering in the intermediate energy range, measurement of the experimental photoemission spectra, their reduction to ARPEFS, and the surface structure determination from the ARPEFS by combined Fourier and multiple-scattering analyses. 202 refs., 67 figs., 2 tabs

  1. Experimental bounds on sterile neutrino mixing angles

    CERN Document Server

    Ruchayskiy, Oleg

    2012-01-01

    We derive bounds on the mixing between the left-chiral ("active") and the right-chiral ("sterile") neutrinos, provided from the combination of neutrino oscillation data and direct experimental searches for sterile neutrinos. We demonstrate that the mixing of sterile neutrinos with any flavour can be significantly suppressed, provided that the angle theta_13 is non-zero. This means that the lower bounds on sterile neutrino lifetime, coming from the negative results of direct experimental searches can be relaxed (by as much as the order of magnitude at some masses). We also demonstrate that the results of the negative searches of sterile neutrinos with PS191 and CHARM experiments are not applicable directly to the see-saw models. The reinterpretation of these results provides up to the order of magnitude stronger bounds on sterile neutrino lifetime than previously discussed in the literature. We discuss the implications of our results for the Neutrino Minimal Standard Model (the NuMSM).

  2. Vascular anomalies of the cerebellopontine angle

    International Nuclear Information System (INIS)

    Papanagiotou, P.; Grunwald, I.Q.; Politi, M.; Struffert, T.; Ahlhelm, F.; Reith, W.

    2006-01-01

    Vascular anomalies of the cerebellopontine angle are rare compared to tumors in this area. Irritation of the trigeminal, facial, or vestibulocochlear nerve may cause trigeminal neuralgia, hemifacial spasm and vertigo, or tinnitus accordingly. Vessel loops in the cerebellopontine cisterns may cause compression at the root entry or exit zone of the cranial nerves V, VII, and VIII, a phenomenon which is called ''vascular loop syndrome.'' Megadolichobasilar artery and aneurysms of the vertebrobasilar system can also lead to dislocation and compression of the cranial nerves and brain stem. Three-dimensional CISS MR imaging and MR angiography are useful in the detection of neurovascular compression. Microvascular decompression is an effective surgical procedure in the management of compression syndromes of the cranial nerves V, VII, and VIII. (orig.) [de

  3. Foreign Body Embedded in Anterior Chamber Angle

    Directory of Open Access Journals (Sweden)

    Shmuel Graffi

    2012-01-01

    Full Text Available Introduction. We present a case of a metallic foreign body embedded in the anterior chamber angle. After standing in close proximity to a construction worker breaking a tile, a 26-year-old woman using soft contact lens for the correction of mild myopia presented to emergency department for evaluation of a foreign body sensation of her right eye. Methods and Results. Diagnosis was confirmed by gonioscopic examination and a noncontrast CT scan of head and orbits. The foreign body was removed by an external approach without utilizing a magnet. The patient's final outcome was favorable. Discussion. The above is a rare clinical situation, which is impossible to detect on slit-lamp examination without a gonioscopic view. Proper imaging and a specific management are mandatory in order to achieve favorable outcome.

  4. Transmission-type angle deviation microscopy

    International Nuclear Information System (INIS)

    Chiu, M.-H.; Lai, C.-W.; Tan, C.-T.; Lai, C.-F.

    2008-01-01

    We present a new microscopy technique that we call transmission angle deviation microscopy (TADM). It is based on common-path heterodyne interferometry and geometrical optics. An ultrahigh sensitivity surface plasmon resonance (SPR) angular sensor is used to expand dynamic measurement ranges and to improve the axial resolution in three-dimensional optical microscopy. When transmitted light is incident upon a specimen, the beam converges or diverges because of refractive and/or surface height variations. Advantages include high axial resolution (∼32 nm), nondestructive and noncontact measurement, and larger measurement ranges (± 80 μm) for a numerical aperture of 0.21in a transparent measurement medium. The technique can be used without conductivity and pretreatment

  5. Mirtazapine-induced acute angle closure

    Directory of Open Access Journals (Sweden)

    Nilay Kahraman

    2015-01-01

    Full Text Available Acute angle closure (AAC is an ocular emergency with symptoms including blurred vision, eye pain, headache, nausea, vomiting and reddening of the eye those results from increased intraocular pressure. This clinical condition can lead to permanent damage in vision, thus causing blindness by generating progressive and irreversible optic neuropathy if left untreated. There are several reasons of AAC, including several types of local and systemic medications; mainly sympathomimetics, cholinergics, anti-cholinergics, mydriatics, anti-histamines, antiepileptics like topiramate, tricyclic and tetracyclic antidepressants, serotonin reuptake inhibitors, antipsychotics, sulfa-based drugs and anticoagulants. Mirtazapine, a noradrenergic and specific serotonergic antidepressant, is an atypical antidepressant with a complex pharmacological profile. This case report describes a patient with major depressive disorder, who experienced AAC after the first dosage of mirtazapine treatment, and highlights the importance of close monitoring of individuals under antidepressant treatment particularly immediately after initiation of the drug.

  6. Multifunctional patchy particles by glancing angle deposition.

    Science.gov (United States)

    Pawar, Amar B; Kretzschmar, Ilona

    2009-08-18

    The application of glancing angle deposition (GLAD) as a means to produce a variety of multifunctional patchy particles is reported. The GLAD technique has been previously used to produce anisotropic particles with an anisotropy dimension of "patchiness". Here, we extend the technique to produce multifunctional patchy particles with anisotropy dimensions of "patchiness", "branching", and "chemical ordering". To access the entire particle surface, a particle stamping technique is employed using a polydimethylsiloxane (PDMS) stamp. The particle stamping technique along with GLAD yields multifunctional patchy particles having patches on opposite poles. The potential of the developed techniques in producing a wide variety of surface-anisotropic particles with variable patch size, shape, and orientation is demonstrated.

  7. Wide Angle Michelson Doppler Imaging Interferometer (WAMDII)

    Science.gov (United States)

    Roberts, B.

    1986-01-01

    The wide angle Michelson Doppler imaging interferometer (WAMDII) is a specialized type of optical Michelson interferometer working at sufficiently long path difference to measure Doppler shifts and to infer Doppler line widths of naturally occurring upper atmospheric Gaussian line emissions. The instrument is intended to measure vertical profiles of atmospheric winds and temperatures within the altitude range of 85 km to 300 km. The WAMDII consists of a Michelson interferometer followed by a camera lens and an 85 x 106 charge coupled device photodiode array. Narrow band filters in a filter wheel are used to isolate individual line emissions and the lens forms an image of the emitting region on the charge coupled device array.

  8. Contact angle measurement of natural materials.

    Science.gov (United States)

    Zhao, Tianyi; Jiang, Lei

    2018-01-01

    Contact angle (CA) is the most important parameter used to quantify the wettability of solid surfaces. In order to evaluate wettability performance, numerous methods have been developed to measure the CA of solid surfaces. Recent years have seen increased focus on the special wettability performance of various biological materials. Biomimetic wettability has become one of the most popular research fields, and novel CA measurements have been invented accordingly. In this protocol, we introduce several CA measurement techniques mainly based on the image capture method, which is commonly to investigate the wettability of natural materials. According to the solid/liquid/gas context, we classify CA measurements into three types: in air, under liquid, and air bubble measurements, and describe methods for each. The precise measurement of CA together with study of surface structure can reveal the mechanisms of special wettability, thus accelerating the investigation of biomaterials. Copyright © 2017. Published by Elsevier B.V.

  9. Correlated evolution of sternal keel length and ilium length in birds

    Directory of Open Access Journals (Sweden)

    Tao Zhao

    2017-07-01

    Full Text Available The interplay between the pectoral module (the pectoral girdle and limbs and the pelvic module (the pelvic girdle and limbs plays a key role in shaping avian evolution, but prior empirical studies on trait covariation between the two modules are limited. Here we empirically test whether (size-corrected sternal keel length and ilium length are correlated during avian evolution using phylogenetic comparative methods. Our analyses on extant birds and Mesozoic birds both recover a significantly positive correlation. The results provide new evidence regarding the integration between the pelvic and pectoral modules. The correlated evolution of sternal keel length and ilium length may serve as a mechanism to cope with the effect on performance caused by a tradeoff in muscle mass between the pectoral and pelvic modules, via changing moment arms of muscles that function in flight and in terrestrial locomotion.

  10. Dilemma of gonial angle measurement: Panoramic radiograph or lateral cephalogram

    Energy Technology Data Exchange (ETDEWEB)

    Radhakrishnan, Pillai Devu; Varma, Nilambur Kovilakam Sapna; Ajith, Vallikat Velath [Dept. of Orthodontics, Amrita School of Dentistry, Kochi (India)

    2017-06-15

    The purpose of this study was to evaluate the accuracy of panoramic imaging in measuring the right and left gonial angles by comparing the measured angles with the angles determined using a lateral cephalogram of adult patients with class I malocclusion. The gonial angles of 50 class I malocclusion patients (25 males and 25 females; mean age: 23 years) were measured using both a lateral cephalogram and a panoramic radiograph. In the lateral cephalograms, the gonial angle was measured at the point of intersection of the ramus plane and the mandibular plane. In the panoramic radiographs, the gonial angle was measured by drawing a line tangent to the lower border of the mandible and another line tangent to the distal border of the ascending ramus and the condyle on both sides. The data obtained from both radiographs were statistically compared. No statistically significant difference was observed between the gonial angle measured using the lateral cephalograms and that determined using the panoramic radiographs. Further, there was no statistically significant difference in the measured gonial angle with respect to gender. The results also showed a statistically insignificant difference in the mean of the right and the left gonial angles measured using the panoramic radiographs. As the gonial angle measurements using panoramic radiographs and lateral cephalograms showed no statistically significant difference, panoramic radiography can be considered in orthodontics for measuring the gonial angle without any interference due to superimposed images.

  11. Improvement on a Michelson interferometer for bunch length measurement of a femtosecond accelerator

    International Nuclear Information System (INIS)

    Lin Xuling; Bei Hua; Zhang Jianbing; Dai Zhimin

    2009-01-01

    Based on the femtosecond accelerator facility at Shanghai Institute of Applied Physics (SINAP), a conventional far-infrared Michelson interferometer was built to measure the bunch length by means of optical autocorrelation. However, according to the preliminary experiment result, the resolution of interferometer is not good enough, because the mirror-driving mechanism makes the moving mirror tend to tilt or wobble as it retards. Considering of the allowable errors, we calculate the maximum allowable titling angle of the moving mirror, and discuss the alignment plan in this paper. (authors)

  12. Optimal protruding node length of bicycle seats determined using cycling postures and subjective ratings.

    Science.gov (United States)

    Chen, Yi-Lang; Liu, Yi-Nan

    2014-07-01

    This study examined body posture, subjective discomfort, and stability, requiring the participants to ride a stationary bicycle for 20 min (cadence: 60 rpm; workrate: 120 W), using various combinations of two handle heights and five seat-protruding node lengths (PNLs). The results indicated that bicycle handle height significantly influenced body posture, and that seat PNL caused differences in the riders' subjective discomfort and stability scores. The various PNLs affected only the trunk angle (approximately 6°), but had significantly positive (r = 0.994, p bicycle seat designs. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  13. Comments on 'Design optimization of a small-angle neutron scattering spectrometer'

    International Nuclear Information System (INIS)

    Mildner, D.F.R.

    1990-01-01

    Margaca, Falcao, Salgado and Carvahlo have recently discussed the design parameters of a small-angle scattering spectrometer. They claim to have shown that the instrument can be optimized for constant angular resolution and a fixed neutron source area, such that the detector count rate is higher than that obtained with a spectrometer optimized for a fixed total length and having the same angular resolution. They also claim that the relative gain in intensity depends upon the size of the neutron emitting surface available to the spectrometer. The initial assumptions made by the authors are too constrained to be generally applicable and therefore misleading conclusions could be drawn, and in fact the equal path length arrangement is optimum. (orig.)

  14. In-situ vapor small angle neutron scattering of sulfonated polyarylenethioethersulfone random copolymer (SPTES 70) fuel cells membrane

    International Nuclear Information System (INIS)

    Yoonessi, Mitra; Bai, Zongwu; Wheeler, Robert; Dang, Thuy D

    2014-01-01

    Highly sulfonated polyarylenethioethersulfone copolymer (SPTES 70) with excellent thermal stability, high proton conductivity and good mechanical properties is an excellent candidate as high temperature fuel cells membrane. The morphology of the SPTES 70 was examined with in situ vapor small angle neutron scattering (iVSANS), and transmission electron microscopy. An experimental neutron contrast match point was obtained with swelling SPTES 70 in a series of D 2 O/H 2 O ratios and compared with the calculated scattering contrast. The calculated scattering length density of SPTES 70 was in excellent agreement with the experiment scattering length density. Small angle neutron scattering (SANS) data of the magnesium, calcium, and silver exchanged hydrated SPTES 70 membranes exhibited nanostructured morphology which was compared with the reported nanostructure of D 2 O hydrated SPTES 70. SANS data showed that the average ionic domain size changes with the size and valence of the counter ion. (paper)

  15. Interdependence of torque, joint angle, angular velocity and muscle action during human multi-joint leg extension.

    Science.gov (United States)

    Hahn, Daniel; Herzog, Walter; Schwirtz, Ansgar

    2014-08-01

    Force and torque production of human muscles depends upon their lengths and contraction velocity. However, these factors are widely assumed to be independent of each other and the few studies that dealt with interactions of torque, angle and angular velocity are based on isolated single-joint movements. Thus, the purpose of this study was to determine force/torque-angle and force/torque-angular velocity properties for multi-joint leg extensions. Human leg extension was investigated (n = 18) on a motor-driven leg press dynamometer while measuring external reaction forces at the feet. Extensor torque in the knee joint was calculated using inverse dynamics. Isometric contractions were performed at eight joint angle configurations of the lower limb corresponding to increments of 10° at the knee from 30 to 100° of knee flexion. Concentric and eccentric contractions were performed over the same range of motion at mean angular velocities of the knee from 30 to 240° s(-1). For contractions of increasing velocity, optimum knee angle shifted from 52 ± 7 to 64 ± 4° knee flexion. Furthermore, the curvature of the concentric force/torque-angular velocity relations varied with joint angles and maximum angular velocities increased from 866 ± 79 to 1,238 ± 132° s(-1) for 90-50° knee flexion. Normalised eccentric forces/torques ranged from 0.85 ± 0.12 to 1.32 ± 0.16 of their isometric reference, only showing significant increases above isometric and an effect of angular velocity for joint angles greater than optimum knee angle. The findings reveal that force/torque production during multi-joint leg extension depends on the combined effects of angle and angular velocity. This finding should be accounted for in modelling and optimisation of human movement.

  16. SIMSAS - a window based software package for simulation and analysis of multiple small-angle scattering data

    International Nuclear Information System (INIS)

    Jayaswal, B.; Mazumder, S.

    1998-09-01

    Small-angle scattering data from strong scattering systems, e.g. porous materials, cannot be analysed invoking single scattering approximation as specimen needed to replicate the bulk matrix in essential properties are too thick to validate the approximation. The presence of multiple scattering is indicated by invalidity of the functional invariance property of the observed scattering profile with variation of sample thickness and/or wave length of the probing radiation. This article delineates how non accounting of multiple scattering affects the results of analysis and then how to correct the data for its effect. It deals with an algorithm to extract single scattering profile from small-angle scattering data affected by multiple scattering. The algorithm can process the scattering data and deduce single scattering profile in absolute scale. A software package, SIMSAS, is introduced for executing this inversion step. This package is useful both to simulate and to analyse multiple small-angle scattering data. (author)

  17. Smith-Purcell Radiation from a Charge Moving Above a Finite-Length Grating

    CERN Document Server

    Kesar, Amit S; Korbly, Stephen; Temkin, Richard J

    2005-01-01

    Smith-Purcell radiation (SPR), emitted when a bunch is passing above a periodic structure, is characterized by a broadband radiation spectrum in which the wavelength depends on the observation angle. While various theoretical models agree on this dependence, a significant difference is introduced for the calculated radiated energy by the different approaches. We present two theoretical calculations of the SPR from a 2D bunch of relativistic electrons passing above a finite length grating. The first one uses the finite-difference time-domain approach and the second one uses an electric-field integral equation (EFIE) method. Good agreement is obtained between these two calculations. The results of these calculations are then compared with a formalism based on an infinite length grating in which a periodic boundary condition is rigorously applied. For gratings with less than approximately 50 periods, a significant error in the strength of the radiated field is introduced by the infinite grating approximation. Th...

  18. The Maquet procedure: effect of tibial shingle length on patellofemoral pressures.

    Science.gov (United States)

    Pan, H Q; Kish, V; Boyd, R D; Burr, D B; Radin, E L

    1993-03-01

    The Maquet procedure--elevation of the anterior tibial tubercle--has been recommended for treatment of symptomatic osteoarthrosis of the patellofemoral joint. Although the operation was first described 30 years ago, it remains controversial, both on a clinical and on a biomechanical basis. In addition, deterioration of the long-term results has been suggested. One of the variables that has been ignored in both clinical and biomechanical studies has been tibial shingle length. In order to judge its effect, we examined contact pressures and areas in 15 cadaver knees with 7 and 20 cm tibial shingle lengths. We found significant patellofemoral pressure diminution only with 2 cm elevations. The short anterior tibial shingle with 2 cm of elevation tipped the patella on its superior pole, with a significant change in angle between the patella and the shingle. We suggest that this creates a potentially less than desirable biomechanical circumstance and believe it may explain the discrepancies among previously published reports.

  19. Effects of Nanoparticle Morphology and Acyl Chain Length on Spontaneous Lipid Transfer Rates.

    Science.gov (United States)

    Xia, Yan; Li, Ming; Charubin, Kamil; Liu, Ying; Heberle, Frederick A; Katsaras, John; Jing, Benxin; Zhu, Yingxi; Nieh, Mu-Ping

    2015-12-01

    We report on studies of lipid transfer rates between different morphology nanoparticles and lipids with different length acyl chains. The lipid transfer rate of dimyristoylphosphatidylcholine (di-C14, DMPC) in discoidal "bicelles" (0.156 h(-1)) is 2 orders of magnitude greater than that of DMPC vesicles (ULVs) (1.1 × 10(-3) h(-1)). For both bicellar and ULV morphologies, increasing the acyl chain length by two carbons [going from di-C14 DMPC to di-C16, dipalmitoylphosphatidylcholine (DPPC)] causes lipid transfer rates to decrease by more than 2 orders of magnitude. Results from small angle neutron scattering (SANS), differential scanning calorimetry (DSC), and fluorescence correlation spectroscopy (FCS) are in good agreement. The present studies highlight the importance of lipid dynamic processes taking place in different morphology biomimetic membranes.

  20. Neutron chain length distributions in subcritical systems

    International Nuclear Information System (INIS)

    Nolen, S.D.; Spriggs, G.

    1999-01-01

    In this paper, the authors present the results of the chain-length distribution as a function of k in subcritical systems. These results were obtained from a point Monte Carlo code and a three-dimensional Monte Carlo code, MC++. Based on these results, they then attempt to explain why several of the common neutron noise techniques, such as the Rossi-α and Feynman's variance-to-mean techniques, are difficult to perform in highly subcritical systems using low-efficiency detectors