WorldWideScience

Sample records for length notes materials

  1. Correlation length estimation in a polycrystalline material model

    International Nuclear Information System (INIS)

    Simonovski, I.; Cizelj, L.

    2005-01-01

    This paper deals with the correlation length estimated from a mesoscopic model of a polycrystalline material. The correlation length can be used in some macroscopic material models as a material parameter that describes the internal length. It can be estimated directly from the strain and stress fields calculated from a finite-element model, which explicitly accounts for the selected mesoscopic features such as the random orientation, shape and size of the grains. A crystal plasticity material model was applied in the finite-element analysis. Different correlation lengths were obtained depending on the used set of crystallographic orientations. We determined that the different sets of crystallographic orientations affect the general level of the correlation length, however, as the external load is increased the behaviour of correlation length is similar in all the analyzed cases. The correlation lengths also changed with the macroscopic load. If the load is below the yield strength the correlation lengths are constant, and are slightly higher than the average grain size. The correlation length can therefore be considered as an indicator of first plastic deformations in the material. Increasing the load above the yield strength creates shear bands that temporarily increase the values of the correlation lengths calculated from the strain fields. With a further load increase the correlation lengths decrease slightly but stay above the average grain size. (author)

  2. Research Note: Inside an Indonesian Online Library for Radical Materials

    Directory of Open Access Journals (Sweden)

    Muhammad Haniff Hassan

    2012-12-01

    Full Text Available This Research Note provides a review of an Indonesian online library for radical materials. The objective of this review is to compile data and information that will contribute to the understanding of the online radicalisation phenomenon as well as the extremists themselves. Based on data found on the online library, this Research Note reports findings on the influence of Al-Maqdisi’s website; the emphasis on translation work of Arabic materials to Indonesian language by radicals and the value of Arabic materials to them. It also covers influential thinkers and ideologues and the use of the Wikipedia modus operandi to hasten the development of the website and effect mobilisation and recruitment, among others things. Based on the data found, this Research Note concludes that ideas matter to radicals.

  3. Fundamental length and relativistic length

    International Nuclear Information System (INIS)

    Strel'tsov, V.N.

    1988-01-01

    It si noted that the introduction of fundamental length contradicts the conventional representations concerning the contraction of the longitudinal size of fast-moving objects. The use of the concept of relativistic length and the following ''elongation formula'' permits one to solve this problem

  4. Multi length-scale characterisation inorganic materials series

    CERN Document Server

    Bruce, Duncan W; Walton, Richard I

    2013-01-01

    Whereas the first five volumes in the Inorganic Materials Series focused on particular classes of materials (synthesis, structures, chemistry, and properties), it is now very timely to provide complementary volumes that introduce and review state-of-the-art techniques for materials characterization. This is an important way of emphasizing the interplay of chemical synthesis and physical characterization. The methods reviewed include spectroscopic, diffraction, and surface techniques that examine the structure of materials on all length scales, from local atomic structure to long-range crystall

  5. Bion's Notes on memory and desire--its initial clinical reception in the United States: a note on archival material.

    Science.gov (United States)

    Aguayo, Joseph

    2014-10-01

    While Bion's 1967 memory and desire paper reflected a crucial episode in his clinical thinking during his epistemological period, it was also central to his evolution as a Kleinian psychoanalyst who worked with seriously disturbed adult patients. The author explicates and contextualizes these claims with a new archival document, the Los Angeles Seminars delivered by Bion in April 1967, and the full-length version of Notes on memory and desire. Bion here instigated a radical departure from years of theory-laden work when he made his clinical work and ideas accessible to a new audience of American Freudian analysts. While this new group was keenly interested to hear about Bion's clinical technique with both borderline and psychotic patients, there were varied reactions to Bion's ideas on the technical implications of the analyst's abandonment of memory and desire. Both the Los Angeles Seminars and Notes elicited responses ranging from bewilderment, admiration to skepticism amongst his audience of listeners and readers. These materials also however allow for a more complete and systematic presentation of important ideas about analytic technique - and while his ideas in this domain have been long valued and known by many psychoanalysts, this contribution stresses the crucial aspect of the reception of his ideas about technique in a particular American context. American analysts gained a much more explicit idea of how Bion worked analytically, how he listened, formulated interpretations and factored in the analyst's listening receptivity in the here-and-now. The author concludes with a consideration of the importance of Bion's American reception in 1967. Copyright © 2014 Institute of Psychoanalysis.

  6. On that Note...

    Science.gov (United States)

    Stein, Harry

    1988-01-01

    Provides suggestions for note-taking from books, lectures, visual presentations, and laboratory experiments to enhance student knowledge, memory, and length of attention span during instruction. Describes topical and structural outlines, visual mapping, charting, three-column note-taking, and concept mapping. Benefits and application of…

  7. Debye screening length effects of nanostructured materials

    CERN Document Server

    Ghatak, Kamakhya Prasad

    2014-01-01

    This monograph solely investigates the Debye Screening Length (DSL) in semiconductors and their nano-structures. The materials considered are quantized structures of non-linear optical, III-V, II-VI, Ge, Te, Platinum Antimonide, stressed materials, Bismuth, GaP, Gallium Antimonide, II-V and Bismuth Telluride respectively. The DSL in opto-electronic materials and their quantum confined counterparts is studied in the presence of strong light waves and intense electric fields on the basis of newly formulated electron dispersion laws that control the studies of such quantum effect devices. The suggestions for the experimental determination of 2D and 3D DSL and the importance of measurement of band gap in optoelectronic materials under intense built-in electric field in nano devices and strong external photo excitation (for measuring photon induced physical properties) have also been discussed in this context. The influence of crossed electric and quantizing magnetic fields on the DSL and the DSL in heavily doped ...

  8. Study on optimum length of raw material in stainless steel high-lock nuts forging

    Science.gov (United States)

    Cheng, Meiwen; Liu, Fenglei; Zhao, Qingyun; Wang, Lidong

    2018-04-01

    Taking 302 stainless steel (1Cr18Ni9) high-lock nuts for research objects, adjusting the length of raw material, then using DEFORM software to simulate the isothermal forging process of each station and conducting the corresponding field tests to study the effects of raw material size on the stainless steel high-lock nuts forming performance. The tests show that the samples of each raw material length is basically the same as the results of the DEFORM software. When the length of the raw material is 10mm, the appearance size of the parts can meet the design requirements.

  9. Copoly(Imide Siloxane) Abhesive Materials with Varied Siloxane Oligomer Length

    Science.gov (United States)

    Wohl, Christopher J.; Atkins, Brad M.; Belcher, Marcus A.; Connell, John W.

    2010-01-01

    Incorporation of PDMS moieties into a polyimide matrix lowered the surface energy resulting in enhanced adhesive interactions. Polyimide siloxane materials were generated using amine-terminated PDMS oligomers of different lengths to study changes in surface migration behavior, phase segregation, mechanical, thermal, and optical properties. These materials were characterized using contact angle goniometry, tensile testing, and differential scanning calorimetry. The surface migration behavior of the PDMS component depended upon the siloxane molecular weight as indicated by distinct relationships between PDMS chain length and advancing water contact angles. Similar correlations were observed for percent elongation values obtained from tensile testing, while the addition of PDMS reduced the modulus. High fidelity topographical modification via laser ablation patterning further reduced the polyimide siloxane surface energy. Initial particulate adhesion testing experiments demonstrated that polyimide siloxane materials exhibited greater abhesive interactions relative to their respective homopolyimides.

  10. Complex technique for materials hardness measurement

    Energy Technology Data Exchange (ETDEWEB)

    Krashchenko, V P; Oksametnaya, O B

    1984-01-01

    A review of existing methods of measurement of material hardness in national and foreign practice has been made. A necessity of improving the technique of material hardness measurement in a wide temperature range and insuring load change with indenting, continuity of imprint application, smooth changing of temperatures along a sample length, and deformation rate control has been noted.

  11. NOTES: issues and technical details with introduction of NOTES into a small general surgery residency program.

    Science.gov (United States)

    Kavic, Michael S; Mirza, Brian; Horne, Walter; Moskowitz, Jesse B

    2008-01-01

    Natural orifice translumenal endoscopic surgery (NOTES) is a development of recent origin. In 2004, Kalloo et al first described NOTES investigation in an animal model. Since then, several investigators have pursued NOTES study in animal survival and nonsurvival models. Our objectives for this project included studying NOTES intervention in a laboratory environment using large animal (swine) models and learning to do so in a safe, controlled manner. Ultimately, we intend to introduce NOTES methodology into our surgical residency training program. The expertise of an experienced laparoscopic surgeon, fellowship-trained laparoendoscopic surgeon, and veterinarian along with a senior surgical resident was utilized to bring the input of several disciplines to this study. The Institutional Animal Care and Use Committee (IACUC) of Northeastern Ohio Universities College of Medicine and Pharmacy (NEOUCOM/COP) approved this study. A series of 5 laboratory sessions using mixed breed farm swine varying in weight from 37 kg to 43.1 kg was planned for the initial phase of NOTES introduction into our residency program. Animals were not kept alive in this investigation. All animals were anesthetized using a standard swine protocol and euthanized following guidelines issued by the American Veterinary Medical Association Panel on Euthanasia. Equipment included a Fujinon EVE endoscope 0.8 cm in diameter with a suction/irrigation channel and one working channel. Initially, a US Endoscopy gastric overtube, 19.5 mm OD and 50 cm in length, was used to facilitate passage of the endoscope. However, this device was found to have insufficient length. Subsequently, commercially available 5/8" diameter clear plastic tubing, 70 cm to 80 cm in length, was adapted for use as an overtube. Standard endoscopic instruments included Boston Scientific biopsy forceps, needle-knife, papillotome, endoscopic clip applier, and Valley Lab electrosurgical unit. A Karl Storz laparoscope and tower were used for

  12. Note on the polishing of small spheres of ferrimagnetic materials

    Energy Technology Data Exchange (ETDEWEB)

    Grunberg, J. G.; Antier, G. [Centre d' etudes nucleaires de Grenoble - C.E.N.G. (France); Seiden, P. E. [Institut Fourier, Universite de Grenoble (France)

    1961-07-01

    This note describes a simple and rapid method that we have used for obtaining a high degree of polish on spheres of ferrimagnetic materials. A high surface polish is of particular importance if one desires to perform ferrimagnetic resonance experiments on very narrow linewidth materials such as Yttrium Iron Garnet. It is not possible to obtain the very narrow linewidths without polishing the sample with a very fine abrasive such as 'Linde A'. Although the methods presently used for the fine polishing of ferrite spheres give satisfactory results, the method described here is of particular interest because of its simplicity and speed. For example with the air-jet tumbling technique it can take as long as three days of polishing to obtain an acceptable surface while our method will give the same results in one to two hours. (author)

  13. Formulating Fermat's principle for light traveling in negative refraction materials

    International Nuclear Information System (INIS)

    Veselago, Viktor G

    2002-01-01

    The formulation of Fermat's principle for electromagnetic waves traveling in materials with a negative refractive index is refined. It is shown that a formulation in terms of the minimum (or extremum) of wave travel time between two points is not correct in general. The correct formulation involves the extremum of the total optical length, with the optical length for the wave propagation through left-handed materials taken to be negative. (methodological notes)

  14. Does an inter-flaw length control the accuracy of rupture forecasting in geological materials?

    Science.gov (United States)

    Vasseur, Jérémie; Wadsworth, Fabian B.; Heap, Michael J.; Main, Ian G.; Lavallée, Yan; Dingwell, Donald B.

    2017-10-01

    Multi-scale failure of porous materials is an important phenomenon in nature and in material physics - from controlled laboratory tests to rockbursts, landslides, volcanic eruptions and earthquakes. A key unsolved research question is how to accurately forecast the time of system-sized catastrophic failure, based on observations of precursory events such as acoustic emissions (AE) in laboratory samples, or, on a larger scale, small earthquakes. Until now, the length scale associated with precursory events has not been well quantified, resulting in forecasting tools that are often unreliable. Here we test the hypothesis that the accuracy of the forecast failure time depends on the inter-flaw distance in the starting material. We use new experimental datasets for the deformation of porous materials to infer the critical crack length at failure from a static damage mechanics model. The style of acceleration of AE rate prior to failure, and the accuracy of forecast failure time, both depend on whether the cracks can span the inter-flaw length or not. A smooth inverse power-law acceleration of AE rate to failure, and an accurate forecast, occurs when the cracks are sufficiently long to bridge pore spaces. When this is not the case, the predicted failure time is much less accurate and failure is preceded by an exponential AE rate trend. Finally, we provide a quantitative and pragmatic correction for the systematic error in the forecast failure time, valid for structurally isotropic porous materials, which could be tested against larger-scale natural failure events, with suitable scaling for the relevant inter-flaw distances.

  15. Automatic Determination of Fiber-Length Distribution in Composite Material Using 3D CT Data

    Science.gov (United States)

    Teßmann, Matthias; Mohr, Stephan; Gayetskyy, Svitlana; Haßler, Ulf; Hanke, Randolf; Greiner, Günther

    2010-12-01

    Determining fiber length distribution in fiber reinforced polymer components is a crucial step in quality assurance, since fiber length has a strong influence on overall strength, stiffness, and stability of the material. The approximate fiber length distribution is usually determined early in the development process, as conventional methods require a destruction of the sample component. In this paper, a novel, automatic, and nondestructive approach for the determination of fiber length distribution in fiber reinforced polymers is presented. For this purpose, high-resolution computed tomography is used as imaging method together with subsequent image analysis for evaluation. The image analysis consists of an iterative process where single fibers are detected automatically in each iteration step after having applied image enhancement algorithms. Subsequently, a model-based approach is used together with a priori information in order to guide a fiber tracing and segmentation process. Thereby, the length of the segmented fibers can be calculated and a length distribution can be deduced. The performance and the robustness of the segmentation method is demonstrated by applying it to artificially generated test data and selected real components.

  16. A note on the length-weight relationship in dolphin fish, Coryphaena hippurus L.

    Digital Repository Service at National Institute of Oceanography (India)

    Chatterji, A.; Ansari, Z.A.

    Length-weight relationship in Coryphaena hippurus almost follows the cube law and the weight of the fish increases more than the square of the length. The value of 'b' was higher in males as compared to females. The equations for length...

  17. Note taking, review, memory, and comprehension.

    Science.gov (United States)

    Bohay, Mark; Blakely, Daniel P; Tamplin, Andrea K; Radvansky, Gabriel A

    2011-01-01

    In previous work assessing memory at various levels of representation, namely the surface form, textbase, and situation model levels, participants read texts but were otherwise not actively engaged with the texts. The current study tested the influence of active engagement with the material via note taking, along with the opportunity to review such notes, and the modality of presentation (text vs. spoken). The influence of these manipulations was assessed both immediately and 1 week later. In Experiment 1 participants read a text, whereas in Experiment 2 participants watched a video recording of the material being read as a lecture. For each experiment the opportunity to take notes was manipulated within participants, and the opportunity to review these notes before the test was manipulated between participants. Note taking improved performance at the situation model level in both experiments, although there was also some suggestion of benefit for the surface form. Thus, active engagement with material, such as note taking, appears to have the greatest benefit at the deeper levels of understanding.

  18. Teaching Furlow palatoplasty: the sticky note method.

    Science.gov (United States)

    Liu, Mona Mengyue; Kim, JeeHong; Jabbour, Noel

    2014-11-01

    The double-opposing Z-plasty (Furlow palatoplasty) procedure is a well-established method for palate repair in children. We propose a simple and easily accessible sticky note model to demonstrate the lengthening in palatal anatomy afforded by this technically challenging procedure. Our model involves creating a lengthened three-dimensional representation of the Z-plasty through making specified incisions and rearrangements of the palatal layers. The sticky note model was made a total of 20 times and length of the palate model pre and post Z-plasty was measured. The average length of the palate pre-procedure was 72 mm. The average length of the palate post procedure was 78.9 mm, showing an increase of 6.9 mm (9.6%). Our model provides an accurate and valuable educational tool that will aid in the visualization and understanding of the Furlow palatoplasty procedure. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  19. Automatic Determination of Fiber-Length Distribution in Composite Material Using 3D CT Data

    Directory of Open Access Journals (Sweden)

    Günther Greiner

    2010-01-01

    Full Text Available Determining fiber length distribution in fiber reinforced polymer components is a crucial step in quality assurance, since fiber length has a strong influence on overall strength, stiffness, and stability of the material. The approximate fiber length distribution is usually determined early in the development process, as conventional methods require a destruction of the sample component. In this paper, a novel, automatic, and nondestructive approach for the determination of fiber length distribution in fiber reinforced polymers is presented. For this purpose, high-resolution computed tomography is used as imaging method together with subsequent image analysis for evaluation. The image analysis consists of an iterative process where single fibers are detected automatically in each iteration step after having applied image enhancement algorithms. Subsequently, a model-based approach is used together with a priori information in order to guide a fiber tracing and segmentation process. Thereby, the length of the segmented fibers can be calculated and a length distribution can be deduced. The performance and the robustness of the segmentation method is demonstrated by applying it to artificially generated test data and selected real components.

  20. Leg Length, Body Proportion, and Health: A Review with a Note on Beauty

    Science.gov (United States)

    Bogin, Barry; Varela-Silva, Maria Inês

    2010-01-01

    Decomposing stature into its major components is proving to be a useful strategy to assess the antecedents of disease, morbidity and death in adulthood. Human leg length (femur + tibia), sitting height (trunk length + head length) and their proportions, for example, (leg length/stature), or the sitting height ratio (sitting height/stature × 100), among others) are associated with epidemiological risk for overweight (fatness), coronary heart disease, diabetes, liver dysfunction and certain cancers. There is also wide support for the use of relative leg length as an indicator of the quality of the environment for growth during infancy, childhood and the juvenile years of development. Human beings follow a cephalo-caudal gradient of growth, the pattern of growth common to all mammals. A special feature of the human pattern is that between birth and puberty the legs grow relatively faster than other post-cranial body segments. For groups of children and youth, short stature due to relatively short legs (i.e., a high sitting height ratio) is generally a marker of an adverse environment. The development of human body proportions is the product of environmental x genomic interactions, although few if any specific genes are known. The HOXd and the short stature homeobox-containing gene (SHOX) are genomic regions that may be relevant to human body proportions. For example, one of the SHOX related disorders is Turner syndrome. However, research with non-pathological populations indicates that the environment is a more powerful force influencing leg length and body proportions than genes. Leg length and proportion are important in the perception of human beauty, which is often considered a sign of health and fertility. PMID:20617018

  1. Storage capacity for fissile material as a function of facility shape (room length-to-width ratio)

    International Nuclear Information System (INIS)

    Altschuler, S.J.

    1975-01-01

    The results of a previous study for applying surface density methods to square room of varying size are shown to be conservative for rectangular rooms as well. The surface density required to produce criticality has been calculated as a function of the facility length-to-width ratio for a variety of room widths and unit sizes, shapes, and fissile material compositions. For a length to width ratio greater than or equal to 6, the critical surface density is essentially constant. This allows further economies since more fissile material can be stored at a given subcritical value of k/ sub eff/(0.90) in a rectangular vault of given usable area than in a square one. (U.S.)

  2. A note on exponential dispersion models which are invariant under length-biased sampling

    NARCIS (Netherlands)

    Bar-Lev, S.K.; van der Duyn Schouten, F.A.

    2003-01-01

    Length-biased sampling situations may occur in clinical trials, reliability, queueing models, survival analysis and population studies where a proper sampling frame is absent.In such situations items are sampled at rate proportional to their length so that larger values of the quantity being

  3. The effect of carbon chain length of starting materials on the formation of carbon dots and their optical properties

    Science.gov (United States)

    Pan, Xiaohua; Zhang, Yan; Sun, Xiaobo; Pan, Wei; Yu, Guifeng; Si, Shuxin; Wang, Jinping

    2018-04-01

    Carbon dots (CDs) have attracted increasing attention due to their high performances and potential applications in wide range of areas. However, their emission mechanism is not clear so far. In order to reveal more factors contributing to the emission of CDs, the effect of carbon chain length of starting materials on the formation of CDs and their optical properties was experimentally investigated in this work. In order to focus on the effect of carbon chain length, the starting materials with C, O, N in fully identical forms and only carbon chain lengths being different were selected for synthesizing CDs, including citric acid (CA) and adipic acid (AA) as carbon sources, and diamines with different carbon chain lengths (H2N(CH2)nNH2, n = 2, 4, 6) as nitrogen sources, as well as ethylenediamine (EDA) as nitrogen source and diacids with different carbon chain lengths (HOOC(CH2)nCOOH, n = 0, 2, 4, 6) as carbon sources. Therefore, the effect of carbon chain length of starting materials on the formation and optical properties of CDs can be systematically investigated by characterizing and comparing the structures and optical properties of as-prepared nine types of CDs. Moreover, the density of –NH2 on the surface of the CDs was quantitatively detected by a spectrophotometry so as to elucidate the relationship between the –NH2 related surface state and the optical properties.

  4. What Limits the Encoding Effect of Note-Taking? A Meta-Analytic Examination

    Science.gov (United States)

    Kobayashi, K.

    2005-01-01

    Previous meta-analyses indicate that the overall encoding effect of note-taking is positive but modest. This meta-analysis of 57 note-taking versus no note-taking comparison studies explored what limits the encoding effect by examining the moderating influence of seven variables: intervention, schooling level, presentation mode and length, test…

  5. Melanie Klein and countertransference: a note on some archival material.

    Science.gov (United States)

    Hinshelwood, R D

    2008-01-01

    Five pages of notes were found in the Melanie Klein Archives at the Wellcome Library that concern her views on countertransference in 1953. Because of the paucity of references to countertransference in Klein's published writings these Notes fill in out knowledge. Her views were provoked by the work her students were doing in their experimental analyses of schizophrenic patients. Apocryphal stories suggest that Klein remained aligned with Freud's view of countertransference as simply interference. The Notes confirm that, whilst there is some truth to that, she did have a more sophisticated and nuanced view of the unconscious relations between analyst and analysand.

  6. Grouping Notes Through NodesThe Functions of Post-It™ Notes in Design Team Cognition

    DEFF Research Database (Denmark)

    Dove, Graham; Abildgaard, Sille Julie; Biskjaer, Michael Mose

    The Post-It™ note is a frequently used, and yet seldom studied, design material. We investigate the functions Post-It™ notes serve when providing cognitive support for creative design team practice. Our investigation considers the ways in which Post-It™ notes function as design externalisations......, both individually and when grouped, and their role in categorisation in semantic long-term memory. To do this, we adopt a multimodal analytical approach focusing on interaction between humans, and between humans and artefacts, alongside language. We discuss in detail examples of four different...... externalisation functions served by Post-It™ notes, and show how these functions are present in complex overlapping combinations rather than being discrete. We then show how the temporal development of Post-It™ note interactions supports categorisation qualities of semantic long-term memory....

  7. Continuously variable focal length lens

    Science.gov (United States)

    Adams, Bernhard W; Chollet, Matthieu C

    2013-12-17

    A material preferably in crystal form having a low atomic number such as beryllium (Z=4) provides for the focusing of x-rays in a continuously variable manner. The material is provided with plural spaced curvilinear, optically matched slots and/or recesses through which an x-ray beam is directed. The focal length of the material may be decreased or increased by increasing or decreasing, respectively, the number of slots (or recesses) through which the x-ray beam is directed, while fine tuning of the focal length is accomplished by rotation of the material so as to change the path length of the x-ray beam through the aligned cylindrical slows. X-ray analysis of a fixed point in a solid material may be performed by scanning the energy of the x-ray beam while rotating the material to maintain the beam's focal point at a fixed point in the specimen undergoing analysis.

  8. A Pedagogic Cycle for EFL Note-Taking

    Science.gov (United States)

    Siegel, Joseph

    2016-01-01

    More attention has been given to note-taking in EFL classrooms in recent years, probably due to growing numbers of EFL students who attend lectures given in English and the importance of note-taking during language proficiency tests. While textbooks and materials for note-taking practice are readily available, classroom techniques for teaching EFL…

  9. PENERAPAN NUMBERED HEAD TOGETHER DENGAN PENDEKATAN GUIDED NOTE TAKING PADA MATERI HIDROKARBON

    Directory of Open Access Journals (Sweden)

    Aryati Vuliana Cesari

    2016-07-01

    Full Text Available Penyampaian materi hidrokarbon dengan metode ceramah perlu dilengkapi dengan metode lain untuk meningkatkan hasil be/ajar yang be/um optimal. Penelitian ini bertujuan untuk mengetahui adanya perbedaan antara hasil be/ajar kimia materi hidrokarbon siswa kelas X SMA menggunakan model pembelajaran kooperatif tipe Numbered Head Together (NHT berpendekatan Guided Note Taking (GNT dengan model pembelajaran konvensional. Populasi penelitian ini adalah siswa kelas X suatu SMA di Semarang tahun ajaran 2011/2012. Analisis data awal hasil be/ajar menghasilkan populasi normal dan homogen. Pengambilan sampel dengan teknik cluster random sampling dengan kelas X-A sebagai kelas eksperimen dan kelas X-0 sebagai kelompok kontrol. Desain Penelitian menggunakan control group pre test post test. Analisis data akhir menggunakan uji t. Analisis tahap akhir menunjukkan bahwa N-gain kelas eksperimen sebesar 0,65 sedangkan kelas control N-gain sebesar 0,56. Dari uji perbedaan rata­ rata diperoleh thitung(2,28> t1abet(2,00 berarti rerata hasil be/ajar kelompok eksperimen lebih baik. Rata-rata hasil be/ajar kelas eksperimen 78,60 dengan ketuntasan klasikal 85,71%. Rata-rata kelas kontrol sebesar 73,43 dengan ketuntasan klasikal sebesar 71,42%, sehingga ada perbedaan yang signifikan pada hasil be/ajar kimia materi hidrokarbon kelas X SMA siswa yang menggunakan model pembelajaran kooperatif tipe NHT berpendekatan GNT terhadap siswa dengan model pembelajaran konvensional.

  10. The effect of distal ulnar implant stem material and length on bone strains.

    Science.gov (United States)

    Austman, Rebecca L; Beaton, Brendon J B; Quenneville, Cheryl E; King, Graham J W; Gordon, Karen D; Dunning, Cynthia E

    2007-01-01

    Implant design parameters can greatly affect load transfer from the implant stem to the bone. We have investigated the effect of length or material of distal ulnar implant stems on the surrounding bone strains. Eight cadaveric ulnas were instrumented with 12 strain gauges and secured in a customized jig. Strain data were collected while loads (5-30 N) were applied to the medial surface of the native ulnar head. The native ulnar head was removed, and a stainless steel implant with an 8-cm-long finely threaded stem was cemented into the canal. After the cement had cured, the 8-cm stem was removed, leaving a threaded cement mantle in the canal that could accept shorter threaded stems of interest. The loading protocol was then repeated for stainless steel stems that were 7, 5, and 3 cm in length, as well as for a 5-cm-long titanium alloy (TiAl(6)V(4)) stem. Other stainless steel stem lengths between 3 and 7 cm were tested at intervals of 0.5 cm, with only a 20 N load applied. No stem length tested matched the native strains at all gauge locations. No significant differences were found between any stem length and the native bone at the 5th and 6th strain gauge positions. Strains were consistently closer to the native bone strains with the titanium stem than the stainless steel stem for each gauge pair that was positioned on the bone overlying the stem. The 3-cm stem results were closer to the native strains than the 7-cm stem for all loads at gauges locations that were on top of the stem. The results from this study suggest that the optimal stem characteristics for distal ulnar implants from a load transfer point of view are possessed by shorter (approximately 3 to 4 cm) titanium stems.

  11. Accurate switching intensities and length scales in quasi-phase-matched materials

    DEFF Research Database (Denmark)

    Bang, Ole; Graversen, Torben Winther; Corney, Joel Frederick

    2001-01-01

    We consider unseeded typeI second-harmonic generation in quasi-phase-matched quadratic nonlinear materials and derive an accurate analytical expression for the evolution of the average intensity. The intensity- dependent nonlinear phase mismatch that is due to the cubic nonlinearity induced...... by quasi phase matching is found. The equivalent formula for the intensity of maximum conversion, the crossing of which changes the one-period nonlinear phase shift of the fundamental abruptly by p , corrects earlier estimates [Opt.Lett. 23, 506 (1998)] by a factor of 5.3. We find the crystal lengths...... that are necessary to obtain an optimal flat phase versus intensity response on either side of this separatrix intensity....

  12. Minority carrier diffusion lengths and absorption coefficients in silicon sheet material

    Science.gov (United States)

    Dumas, K. A.; Swimm, R. T.

    1980-01-01

    Most of the methods which have been developed for the measurement of the minority carrier diffusion length of silicon wafers require that the material have either a Schottky or an ohmic contact. The surface photovoltage (SPV) technique is an exception. The SPV technique could, therefore, become a valuable diagnostic tool in connection with current efforts to develop low-cost processes for the production of solar cells. The technique depends on a knowledge of the optical absorption coefficient. The considered investigation is concerned with a reevaluation of the absorption coefficient as a function of silicon processing. A comparison of absorption coefficient values showed these values to be relatively consistent from sample to sample, and independent of the sample growth method.

  13. Energy materials. Advances in characterization, modelling and application

    International Nuclear Information System (INIS)

    Andersen, N.H.; Eldrup, M.; Hansen, N.; Juul Jensen, D.; Nielsen, E.M.; Nielsen, S.F.; Soerensen, B.F.; Pedersen, A.S.; Vegge, T.; West, S.S.

    2008-01-01

    Energy-related topics in the modern world and energy research programmes cover the range from basic research to applications and structural length scales from micro to macro. Materials research and development is a central part of the energy area as break-throughs in many technologies depend on a successful development and validation of new or advanced materials. The Symposium is organized by the Materials Research Department at Risoe DTU - National Laboratory for Sustainable Energy. The Department concentrates on energy problems combining basic and applied materials research with special focus on the key topics: wind, fusion, superconductors and hydrogen. The symposium is based on these key topics and focus on characterization of materials for energy applying neutron, X-ray and electron diffraction. Of special interest is research carried out at large facilities such as reactors and synchrotrons, supplemented by other experimental techniques and modelling on different length scales that underpins experiments. The Proceedings contain 15 key note presentations and 30 contributed presentations, covering the abovementioned key topics relevant for the energy materials. The contributions clearly show the importance of materials research when developing sustainable energy technologies and also that many challenges remain to be approached. (BA)

  14. Editorial note

    DEFF Research Database (Denmark)

    Gani, Rafiqul; Hrymak, A.; Lee, J.

    2009-01-01

    industrial and educational applications. These articles will highlight theory, models, algorithms and applications with respect to value preservation and/or value creation or growth within the chemical product supply chain. To highlight and motivate research in the emerging challenges in PSE, we plan...... components of PSE—modeling, numerical analysis, optimization, systems and control theory, computer science, and, management science will be highlighted through the published articles (full-length papers, perspective papers, review papers, short notes and letters to the editor). They will cover...... and intelligent systems, integrated approaches to design, control and data analysis, systematic techniques for managing complexity, etc.), PSE emerging domains (product-process design, enterprise-wide optimization, energy and sustainability, biological engineering, pharmaceutical engineering, etc.) and novel...

  15. Using Guided Notes to Enhance Instruction for All Students

    Science.gov (United States)

    Konrad, Moira; Joseph, Laurice M.; Itoi, Madoka

    2011-01-01

    Taking notes from lectures or reading material can be challenging, especially for those who have learning disabilities. An alternative to traditional note-taking is a method called "guided notes," which has been found to improve the accuracy of students' notes, increase the frequency of student responses, and improve students' quiz and test…

  16. Mysore study: A study of suicide notes.

    Science.gov (United States)

    Namratha, P; Kishor, M; Sathyanarayana Rao, T S; Raman, Rajesh

    2015-01-01

    Suicide is one of the leading causes of preventable deaths. Recent data suggest South India as one of the regions with highest suicide rates in the world. In 2013, 134,799 people committed suicide in India according to the statistics released by the National Crime Records Bureau. Suicide note is one of the most important sources to understand suicide, which may be beneficial in suicide prevention. Studies on suicidal notes from this part of the world are sparse. The aim was to study the themes in suicide notes that might be useful in prevention strategies. A descriptive study of all suicide notes of those individuals who committed suicide between 2010 and 2013 available with Police Department, Mysore district was obtained and analyzed. A total of 22 suicide note were available. A majority of suicide note was in age group of 16-40 years (86%) and most were men (59%). All suicide notes were handwritten, the majority (70%) in regional language Kannada. Length of notes varied from just few words to few pages. Contents of suicide notes included apology/shame/guilt (80%), love for those left behind (55%) and instruction regarding practical affairs (23%). Most have blamed none for the act (50%). 23% mentioned that they are committing suicide to prove their innocence. 32% mentioned a last wish. The majority of suicidal note contained "guilt" which is a strong indicator of possible depression in deceased. Creating awareness about suicide among public and ensuring access to professionals trained in suicide prevention is need of the hour in this part of the world.

  17. Models for mean bonding length, melting point and lattice thermal expansion of nanoparticle materials

    International Nuclear Information System (INIS)

    Omar, M.S.

    2012-01-01

    Graphical abstract: Three models are derived to explain the nanoparticles size dependence of mean bonding length, melting temperature and lattice thermal expansion applied on Sn, Si and Au. The following figures are shown as an example for Sn nanoparticles indicates hilly applicable models for nanoparticles radius larger than 3 nm. Highlights: ► A model for a size dependent mean bonding length is derived. ► The size dependent melting point of nanoparticles is modified. ► The bulk model for lattice thermal expansion is successfully used on nanoparticles. -- Abstract: A model, based on the ratio number of surface atoms to that of its internal, is derived to calculate the size dependence of lattice volume of nanoscaled materials. The model is applied to Si, Sn and Au nanoparticles. For Si, that the lattice volume is increases from 20 Å 3 for bulk to 57 Å 3 for a 2 nm size nanocrystals. A model, for calculating melting point of nanoscaled materials, is modified by considering the effect of lattice volume. A good approach of calculating size-dependent melting point begins from the bulk state down to about 2 nm diameter nanoparticle. Both values of lattice volume and melting point obtained for nanosized materials are used to calculate lattice thermal expansion by using a formula applicable for tetrahedral semiconductors. Results for Si, change from 3.7 × 10 −6 K −1 for a bulk crystal down to a minimum value of 0.1 × 10 −6 K −1 for a 6 nm diameter nanoparticle.

  18. Models for mean bonding length, melting point and lattice thermal expansion of nanoparticle materials

    Energy Technology Data Exchange (ETDEWEB)

    Omar, M.S., E-mail: dr_m_s_omar@yahoo.com [Department of Physics, College of Science, University of Salahaddin-Erbil, Arbil, Kurdistan (Iraq)

    2012-11-15

    Graphical abstract: Three models are derived to explain the nanoparticles size dependence of mean bonding length, melting temperature and lattice thermal expansion applied on Sn, Si and Au. The following figures are shown as an example for Sn nanoparticles indicates hilly applicable models for nanoparticles radius larger than 3 nm. Highlights: ► A model for a size dependent mean bonding length is derived. ► The size dependent melting point of nanoparticles is modified. ► The bulk model for lattice thermal expansion is successfully used on nanoparticles. -- Abstract: A model, based on the ratio number of surface atoms to that of its internal, is derived to calculate the size dependence of lattice volume of nanoscaled materials. The model is applied to Si, Sn and Au nanoparticles. For Si, that the lattice volume is increases from 20 Å{sup 3} for bulk to 57 Å{sup 3} for a 2 nm size nanocrystals. A model, for calculating melting point of nanoscaled materials, is modified by considering the effect of lattice volume. A good approach of calculating size-dependent melting point begins from the bulk state down to about 2 nm diameter nanoparticle. Both values of lattice volume and melting point obtained for nanosized materials are used to calculate lattice thermal expansion by using a formula applicable for tetrahedral semiconductors. Results for Si, change from 3.7 × 10{sup −6} K{sup −1} for a bulk crystal down to a minimum value of 0.1 × 10{sup −6} K{sup −1} for a 6 nm diameter nanoparticle.

  19. Density Functional Theory and Materials Modeling at Atomistic Length Scales

    Directory of Open Access Journals (Sweden)

    Swapan K. Ghosh

    2002-04-01

    Full Text Available Abstract: We discuss the basic concepts of density functional theory (DFT as applied to materials modeling in the microscopic, mesoscopic and macroscopic length scales. The picture that emerges is that of a single unified framework for the study of both quantum and classical systems. While for quantum DFT, the central equation is a one-particle Schrodinger-like Kohn-Sham equation, the classical DFT consists of Boltzmann type distributions, both corresponding to a system of noninteracting particles in the field of a density-dependent effective potential, the exact functional form of which is unknown. One therefore approximates the exchange-correlation potential for quantum systems and the excess free energy density functional or the direct correlation functions for classical systems. Illustrative applications of quantum DFT to microscopic modeling of molecular interaction and that of classical DFT to a mesoscopic modeling of soft condensed matter systems are highlighted.

  20. Notes on radiation effects on materials

    International Nuclear Information System (INIS)

    Anno, J.N.

    1984-01-01

    The effects of radiation from nuclear reactions on various classes of materials are examined in an introductory textbook for students of nuclear engineering. Topics discussed include the units and general scale of radiation damage, fundamental interactions of neutrons and gamma rays with materials, transient radiation effects on electrical components, radiation effects on organic materials and on steels, nuclear fission effects, surface effects of nuclear radiations, radiation effects on biological material, and neutron and gamma-ray dosimetry. Graphs, diagrams, tables of numerical data, and problems for each chapter are provided. 122 references

  1. Multi-length-scale Material Model for SiC/SiC Ceramic-Matrix Composites (CMCs): Inclusion of In-Service Environmental Effects

    Science.gov (United States)

    Grujicic, M.; Galgalikar, R.; Snipes, J. S.; Ramaswami, S.

    2016-01-01

    In our recent work, a multi-length-scale room-temperature material model for SiC/SiC ceramic-matrix composites (CMCs) was derived and parameterized. The model was subsequently linked with a finite-element solver so that it could be used in a general room-temperature, structural/damage analysis of gas-turbine engine CMC components. Due to its multi-length-scale character, the material model enabled inclusion of the effects of fiber/tow (e.g., the volume fraction, size, and properties of the fibers; fiber-coating material/thickness; decohesion properties of the coating/matrix interfaces; etc.) and ply/lamina (e.g., the 0°/90° cross-ply versus plain-weave architectures, the extent of tow crimping in the case of the plain-weave plies, cohesive properties of the inter-ply boundaries, etc.) length-scale microstructural/architectural parameters on the mechanical response of the CMCs. One of the major limitations of the model is that it applies to the CMCs in their as-fabricated conditions (i.e., the effect of prolonged in-service environmental exposure and the associated material aging-degradation is not accounted for). In the present work, the model is upgraded to include such in-service environmental-exposure effects. To demonstrate the utility of the upgraded material model, it is used within a finite-element structural/failure analysis involving impact of a toboggan-shaped turbine shroud segment by a foreign object. The results obtained clearly revealed the effects that different aspects of the in-service environmental exposure have on the material degradation and the extent of damage suffered by the impacted CMC toboggan-shaped shroud segment.

  2. Lecture notes on quantum statistics

    NARCIS (Netherlands)

    Gill, R.D.

    2000-01-01

    These notes are meant to form the material for an introductory course on quantum statistics at the graduate level aimed at mathematical statisticians and probabilists No background in physics quantum or otherwise is required They are still far from complete

  3. 46 CFR 403.120 - Notes to financial statements.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 8 2010-10-01 2010-10-01 false Notes to financial statements. 403.120 Section 403.120... ACCOUNTING SYSTEM General § 403.120 Notes to financial statements. (a) All matters that are not clearly identified in the body of the financial statements of the Association, but which may materially influence...

  4. A NOTE ON THE POCHHAMMER FREQUENCY EQUATION

    African Journals Online (AJOL)

    cistvr

    A note on the Pochhammer frequency equation. ),,,,(. ),,,,(;/. 2 zwura. ZWURA. tT ρω. µ. = ω= , where ωis the angular frequency of the wave, which is considered to be imposed in this problem. We also introduce a material parameter α defined by. )2. /(. µ+λµ=α , which is related to Poisson's ratio ν by n- n-. =a. 22. 21 . We note ...

  5. A note on hypoplastic yielding

    OpenAIRE

    Nader, José Jorge

    2010-01-01

    This note discusses briefly the definition of yield surface in hypoplasticity in connection with the physical notion of yielding. The relation of yielding with the vanishing of the material time derivative of the stress tensor and the vanishing of the corotational stress rate is investigated.

  6. Notes on basic materials (1)

    International Nuclear Information System (INIS)

    Donald, R.

    1976-01-01

    This lecture was a revision of basic material, intended for students who were mainly postgraduate at the end of their first year in experimental high energy physics. The subject headings include the following: notation and generalities; classification of particles; symmetry arguments; higher symmetries; SU 3 isoscalar factors; predictions from SU 3; charm; relativistic wave equations; Feynman graphical techniques. (U.K.)

  7. A study of actions in operative notes.

    Science.gov (United States)

    Wang, Yan; Pakhomov, Serguei; Burkart, Nora E; Ryan, James O; Melton, Genevieve B

    2012-01-01

    Operative notes contain rich information about techniques, instruments, and materials used in procedures. To assist development of effective information extraction (IE) techniques for operative notes, we investigated the sublanguage used to describe actions within the operative report 'procedure description' section. Deep parsing results of 362,310 operative notes with an expanded Stanford parser using the SPECIALIST Lexicon resulted in 200 verbs (92% coverage) including 147 action verbs. Nominal action predicates for each action verb were gathered from WordNet, SPECIALIST Lexicon, New Oxford American Dictionary and Stedman's Medical Dictionary. Coverage gaps were seen in existing lexical, domain, and semantic resources (Unified Medical Language System (UMLS) Metathesaurus, SPECIALIST Lexicon, WordNet and FrameNet). Our findings demonstrate the need to construct surgical domain-specific semantic resources for IE from operative notes.

  8. Aminophylline increases seizure length during electroconvulsive therapy.

    Science.gov (United States)

    Stern, L; Dannon, P N; Hirschmann, S; Schriber, S; Amytal, D; Dolberg, O T; Grunhaus, L

    1999-12-01

    Electroconvulsive therapy (ECT) is considered to be one of the most effective treatments for patients with major depression and persistent psychosis. Seizure characteristics probably determine the therapeutic effect of ECT; as a consequence, short seizures are accepted as one of the factors of poor outcome. During most ECT courses seizure threshold increases and seizure duration decreases. Methylxanthine preparations, caffeine, and theophylline have been used to prolong seizure duration. The use of aminophylline, more readily available than caffeine, has not been well documented. The objective of this study was to test the effects of aminophylline on seizure length. Fourteen drug-free patients with diagnoses of affective disorder or psychotic episode receiving ECT participated in this study. Seizure length was assessed clinically and per EEG. Statistical comparisons were done using paired t tests. A significant increase (p < 0.04) in seizure length was achieved and maintained on three subsequent treatments with aminophylline. No adverse events were noted from the addition of aminophylline.

  9. Digital Note-Taking: Discussion of Evidence and Best Practices.

    Science.gov (United States)

    Grahame, Jason A

    2016-03-01

    Balancing active course engagement and comprehension with producing quality lecture notes is challenging. Although evidence suggests that handwritten note-taking may improve comprehension and learning outcomes, many students still self-report a preference for digital note-taking and a belief that it is beneficial. Future research is warranted to determine the effects on performance of digitally writing notes. Independent of the methods or software chosen, best practices should be provided to students with information to help them consciously make an educated decision based on the evidence and their personal preference. Optimal note-taking requires self-discipline, focused attention, sufficient working memory, thoughtful rewording, and decreased distractions. Familiarity with the tools and mediums they choose will help students maximize working memory, produce better notes, and aid in their retention of material presented.

  10. The Effects of Guided Notes on Pre-Lecture Quiz Scores in Introductory Psychology

    Science.gov (United States)

    Glodowski, Kathryn; Thompson, Rachel

    2018-01-01

    Guided notes covering lectures have been shown to improve note quality and increase scores on quizzes covering lecture material. We sought to determine whether guided notes would also be beneficial in helping students prepare for quizzes covering assigned readings. We evaluated the efficacy of guided notes for reading assignments on…

  11. Remedial action programs annual meeting: Meeting notes

    International Nuclear Information System (INIS)

    1987-01-01

    The US Department of Energy Grand Junction Projects Office was pleased to host the 1987 Remedial Action programs Annual Meeting and herein presents notes from that meeting as prepared (on relatively short notice) by participants. These notes are a summary of the information derived from the workshops, case studies, and ad hoc committee reports rather than formal proceedings. The order of the materials in this report follows the actual sequence of presentations during the annual meeting

  12. Note Taking Activity and its assessment in a Blended Learning Environment

    OpenAIRE

    Nakayama, Minoru; Mutsuura, Kouichi; Yamamoto, Hiroh

    2017-01-01

    "Note-taking" is a popular skill for all types of learning activities. In recent years, the online educational environment has began spreading rapidly at institutes of higher educational, obviating the need for printed materials or written notes. This means that students’ ability to take notes may decline and this may influence the success of their learning.  In order to examine this phenomenon, students' notes were surveyed during a blended learning course in a bachelor level program at...

  13. Note Taking and Note Sharing While Browsing Campaign Information

    DEFF Research Database (Denmark)

    Robertson, Scott P.; Vatrapu, Ravi; Abraham, George

    2009-01-01

    Participants were observed while searching and browsing the internet for campaign information in a mock-voting situation in three online note-taking conditions: No Notes, Private Notes, and Shared Notes. Note taking significantly influenced the manner in which participants browsed for information...

  14. Note by Note: a New Revolution in Cooking

    OpenAIRE

    Burke, Roisin; Danaher, Pauline

    2016-01-01

    Note by note cooking is an application of Molecular Gastronomy. It was first proposed by French Physical Chemist and Molecular Gastronomy Co-founder, Hervé This. Note by Note dishes are being created as part of Ph.D. research in the Dublin Institute of Technology, Cathal Brugha Street.

  15. Root Length and Anatomy of Impacted Maxillary Canines in Patients with Unilateral Maxillary Canine Impaction

    Directory of Open Access Journals (Sweden)

    Mostfa Shahabi

    2017-09-01

    Full Text Available Introduction: Canine impaction is a common occurrence. In this study, we sought to investigate the root anatomy and length of impacted canines and lateral incisor adjacent to impacted maxillary canine. Materials and Methods: In this retrospective study, three-dimensional tomographic imaging was performed on 26 patients with unilateral maxillary canine impaction. In this study, we evaluated root length and anatomy of impacted canines, in terms of resorption intensity and curvature, with Planmeca Romexis Viewer 4.0. Furthermore, crown shape as well as root length and anatomy of the lateral incisors adjacent to impacted canines were investigated and compared with the other side on the dental arch, where canine eruption was normal. Results: Root length of impacted canines was significantly lower than that of normal canines (P=0.011. There were no significant differences between root length of lateral incisors adjacent to impacted canines and root length of lateral incisors adjacent to normal canines (P=0.221. Moreover, the resorption intensity of the adjacent lateral incisors was higher than that of the impacted canines. No significant differences were noted in root resorption intensity between the lateral incisors adjacent to the imacted canines and the lateral incisors adjacent to normal canines (P=0.36. In addition, resorption intensity was significantly higher in impacted canines than in normal canines (P=0.024. Root anatomy of impacted canines was not significantly different from that of normal canines (P=0.055. The crown shape of the lateral incisors adjacent to impacted canines was not significantly different from that of the lateral incisors adjacent to normal canines (P=0.052. Conclusion: Impaction can probably affect root length and canine resorption severity. However, root and crown shape of lateral incisors cannot always be associated with canine impaction.

  16. Analysing playing using the note-time playing path.

    Science.gov (United States)

    de Graaff, Deborah L E; Schubert, Emery

    2011-03-01

    This article introduces a new method of data analysis that represents the playing of written music as a graph. The method, inspired by Miklaszewski, charts low-level note timings from a sound recording of a single-line instrument using high-precision audio-to-MIDI conversion software. Note onset times of pitch sequences are then plotted against the score-predicted timings to produce a Note-Time Playing Path (NTPP). The score-predicted onset time of each sequentially performed note (horizontal axis) unfolds in performed time down the page (vertical axis). NTPPs provide a visualisation that shows (1) tempo variations, (2) repetitive practice behaviours, (3) segmenting of material, (4) precise note time positions, and (5) time spent on playing or not playing. The NTPP can provide significant new insights into behaviour and cognition of music performance and may also be used to complement established traditional approaches such as think-alouds, interviews, and video coding.

  17. How is adult patient adherence recorded in orthodontists’ clinical notes? A mixed-method case-note study

    Directory of Open Access Journals (Sweden)

    Al Shammary N

    2017-10-01

    Full Text Available Nawaf Al Shammary,1 Koula Asimakopoulou,1 Fraser McDonald,2 Jonathon T Newton,1 Sasha Scambler1 1Division of Population and Patient Health, 2Craniofacial Development and Stem Cell Biology Department, King’s College London Dental Institute, London, UKBackground: Patient adherence in orthodontic treatment is extremely important as it is linked with better treatment outcomes. Despite its importance, however, there is no shared definition of the concept. This makes the recording of adherence-related behaviors in patient notes difficult. The current study explored how, and to what extent adherence is recorded in adult patients’ medical records by orthodontists working in a large National Health Service (NHS London hospital.Materials and methods: A mixed-methods approach was used. A total of 17 clinicians with a mean age of 31 years (SD =4.87 provided N=20 case notes spanning N=324 appointments with patients they judged to be non-adherent. The notes were inspected for evidence of recording of patient adherence using adherence indicators identified in the literature.Results: The term “adherence” did not feature in any notes. The quantitative analysis showed that the three most frequent adherence-related behaviors recorded in notes were “oral hygiene,” “appointment attendance” and “breakages of appliances.” Qualitative analysis not only confirmed these factors but also showed that 1 the clinical aspects of treatment, 2 clinician–patient interaction factors and 3 patient attitudes also featured. This part of the analysis also highlighted inconsistencies across case notes in terms of the amount of information being recorded.Conclusion: Adherence as a term does not feature in the clinical case notes of clinician-identified non-adherent adult patients, while predictors of adherence are recorded with varying degrees of consistency. Keywords: adherence, adults, orthodontic treatment

  18. Microcomputer system for controlling fuel rod length

    International Nuclear Information System (INIS)

    Meyer, E.R.; Bouldin, D.W.; Bolfing, B.J.

    1979-01-01

    A system is being developed at the Oak Ridge National Laboratory (ORNL) to automatically measure and control the length of fuel rods for use in a high temperature gas-cooled reactor (HTGR). The system utilizes an LSI-11 microcomputer for monitoring fuel rod length and for adjusting the primary factor affecting length. Preliminary results indicate that the automated system can maintain fuel rod length within the specified limits of 1.940 +- 0.040 in. This system provides quality control documentation and eliminates the dependence of the current fuel rod molding process on manual length control. In addition, the microcomputer system is compatible with planned efforts to extend control to fuel rod fissile and fertile material contents

  19. 36 CFR 1254.12 - Will NARA log or inspect my computer, other equipment, and notes?

    Science.gov (United States)

    2010-07-01

    ... personal notes into the research room. In research rooms that permit taking in your notes, a NARA or... computer, other equipment, and notes? 1254.12 Section 1254.12 Parks, Forests, and Public Property NATIONAL... MATERIALS General Information § 1254.12 Will NARA log or inspect my computer, other equipment, and notes? (a...

  20. Lecture notes for criticality safety

    International Nuclear Information System (INIS)

    Fullwood, R.

    1992-03-01

    These lecture notes for criticality safety are prepared for the training of Department of Energy supervisory, project management, and administrative staff. Technical training and basic mathematics are assumed. The notes are designed for a two-day course, taught by two lecturers. Video tapes may be used at the options of the instructors. The notes provide all the materials that are necessary but outside reading will assist in the fullest understanding. The course begins with a nuclear physics overview. The reader is led from the macroscopic world into the microscopic world of atoms and the elementary particles that constitute atoms. The particles, their masses and sizes and properties associated with radioactive decay and fission are introduced along with Einstein's mass-energy equivalence. Radioactive decay, nuclear reactions, radiation penetration, shielding and health-effects are discussed to understand protection in case of a criticality accident. Fission, the fission products, particles and energy released are presented to appreciate the dangers of criticality. Nuclear cross sections are introduced to understand the effectiveness of slow neutrons to produce fission. Chain reactors are presented as an economy; effective use of the neutrons from fission leads to more fission resulting in a power reactor or a criticality excursion. The six-factor formula is presented for managing the neutron budget. This leads to concepts of material and geometric buckling which are used in simple calculations to assure safety from criticality. Experimental measurements and computer code calculations of criticality are discussed. To emphasize the reality, historical criticality accidents are presented in a table with major ones discussed to provide lessons-learned. Finally, standards, NRC guides and regulations, and DOE orders relating to criticality protection are presented

  1. Some problems of special theory of relativity. (Concept of relativistic length)

    International Nuclear Information System (INIS)

    Strel'tsov, V.N.

    1977-01-01

    Two available definitions of the concept of length (distance) related (a) to moving the length standard and (b) to sending a light signal (similar to the radar method for measuring distances) are analyzed. Considerations in favour of the preferable use of the (b) definition are discussed. The extension of the (b) definition for fast moving bodies results in the introduction of the definition of relativistic length and volume. The increase of the longitudinal dimensions of fast moving objects is a consequence of the above definition. It should be noted that, e.g., for a rod, the definition corresponds to measurements on the lines orthogonal to the world strip of the given rod. It is shown that the known Michelson-Morley and Throuton-Noble experiments are naturally explained in the framework of the proposed concept of relativistic length. It is also shown that the definition introduced, unlike the conventional one, satisfies the principle of relativity

  2. The length of the male urethra

    Directory of Open Access Journals (Sweden)

    Tobias. S. Kohler

    2008-08-01

    Full Text Available PURPOSE: Catheter-based medical devices are an important component of the urologic armamentarium. To our knowledge, there is no population-based data regarding normal male urethral length. We evaluated the length of the urethra in men with normal genitourinary anatomy undergoing either Foley catheter removal or standard cystoscopy. MATERIALS AND METHODS: Male urethral length was obtained in 109 men. After study permission was obtained, the subject's penis was placed on a gentle stretch and the catheter was marked at the tip of the penis. The catheter was then removed and the distance from the mark to the beginning of the re-inflated balloon was measured. Alternatively, urethral length was measured at the time of cystoscopy, on removal of the cystoscope. Data on age, weight, and height was obtained in patients when possible. RESULTS: The mean urethral length was 22.3 cm with a standard deviation of 2.4 cm. Urethral length varied between 15 cm and 29 cm. No statistically significant correlation was found between urethral length and height, weight, body mass index (BMI, or age. CONCLUSIONS: Literature documenting the length of the normal male adult urethra is scarce. Our data adds to basic anatomic information of the male urethra and may be used to optimize genitourinary device design.

  3. Study on the Connecting Length of CFRP

    Science.gov (United States)

    Liu, Xiongfei; Li, Yue; Li, Zhanguo

    2018-05-01

    The paper studied the varying mode of shear stress in the connecting zone of CFRP. Using epoxy resin (EP) as bond material, performance of specimens with different connecting length of CFRP was tested to obtain the conclusion. CFRP-confined concrete column was tested subsequently to verify the conclusion. The results show that: (1) The binding properties of modified epoxy resin with CFRP is good; (2) As the connecting length increased, the ultimate tensile strength of CFRP increased as well in the range of the experiment parameters; (3) Tensile strength of CFRP can reach the ultimate strength when the connecting length is 90mm;(4) The connecting length of 90mm of CFRP meet the reinforcement requirements.

  4. Properties of selected superconductive materials, 1978 supplement. Technical note

    International Nuclear Information System (INIS)

    Roberts, B.W.

    1978-10-01

    This report includes data on additional superconductive materials extracted from the world literature up to fall 1977 and is an addendum to the data set published in J. Phys. Chem. Ref. Data 5, no. 3, 581-821 (1976) (Reprint no. 84). The data presented are new values and have not been selected or compared to values (except for selected values of the elements) previously assembled by the Superconductive Materials Data Center. The properties included are composition, critical temperature, critical magnetic field, crystal structure and the results of negative experiments. Special tabulations of high magnetic field materials with Type II behavior and materials with organic components are included. All entries are keyed to the literature. A list of recent reviews centered on superconductive materials is included

  5. Analysis of ureteral length in adult cadavers

    Directory of Open Access Journals (Sweden)

    Hugo F. F. Novaes

    2013-04-01

    Full Text Available Introduction In some occasions, correlations between human structures can help planning surgical intra-abdominal interventions. The previous determination of ureteral length helps pre-operatory planning of surgeries, reduces costs of auxiliary exams, the correct choice of double-J catheter with low morbidity and fewer symptoms, and an adequate adhesion to treatment. Objective To evaluate ureteral length in adult cadavers and to analyze its correlation with anthropometric measures. Materials and Methods: From April 2009 to January 2012 we determined ureteral length of adult cadavers submitted to necropsy and obtained the following measures: height, distance from shoulder to wrist, elbow-wrist, xiphoid appendix-umbilicus, umbilicus-pubis, xiphoid appendix-pubis and between iliac spines. We analyzed the correlations between ureteral length and those anthropometric measures. Results We dissected 115 ureters from 115 adult corpses from April 2009 to January 2012. Median ureteral length didn't vary between sexes or according to height. It was observed no correlation among ureteral length and all considered anthropometric measures in all analyzed subgroups and in general population. There were no significant differences between right and left ureteral measures. Conclusions There is no difference of ureteral length in relation to height or gender (male or female. There is no significant correlation among ureteral length and the considered anthropometric measures.

  6. Note Taking on Trial: A Legal Application of Note-Taking Research

    Science.gov (United States)

    Kiewra, Kenneth A.

    2016-01-01

    This article is about note taking, but it is not an exhaustive review of note-taking literature. Instead, it portrays the application of note-taking research to an unusual and important area of practice--the law. I was hired to serve as an expert witness on note taking in a legal case that hinged, in part, on the completeness and accuracy of…

  7. A Small Crack Length Evaluation Technique by Electronic Scanning

    International Nuclear Information System (INIS)

    Cho, Yong Sang; Kim, Jae Hoon

    2009-01-01

    The results of crack evaluation by conventional UT(Ultrasonic Test)is highly depend on the inspector's experience or knowledge of ultrasound. Phased array UT system and its application methods for small crack length evaluation will be a good alternative method which overcome present UT weakness. This study was aimed at checking the accuracy of crack length evaluation method by electronic scanning and discuss about characteristics of electronic scanning for crack length evaluation. Especially ultrasonic phased array with electronic scan technique was used in carrying out both sizing and detect ability of crack as its length changes. The response of ultrasonic phased array was analyzed to obtain the special method of determining crack length without moving the transducer and detectability of crack minimal length and depth from the material. A method of crack length determining by electronic scanning for the small crack is very real method which has it's accuracy and verify the effectiveness of method compared to a conventional crack length determination

  8. The Impact of Note Taking On the Improvement of Listening Comprehension of Iranian EFL Learners

    OpenAIRE

    Mohammad Zohrabi; Farzaneh Esfandyari

    2014-01-01

    Note taking is a popular and operative strategy which increases the students? ability to remember, comprehend, and keep the material in mind. Nowadays, it is very common for teachers to use the note taking strategy in EFL listening classes due to the fact that taking notes can help students catch the main points easily and in turn promote their listening comprehension effectively. However, it creates areas of concerns for some researchers about whether taking notes is effective for students t...

  9. [Renal length measured by ultrasound in adult mexican population].

    Science.gov (United States)

    Oyuela-Carrasco, J; Rodríguez-Castellanos, F; Kimura, E; Delgado-Hernández, R; Herrera-Félix, J P

    2009-01-01

    Renal length estimation by ultrasound is an important parameter in clinical evaluation of kidney disease and healthy donors. Changes in renal volume may be a sign of kidney disease. Correct interpretation of renal length requires the knowledge of normal limits, these have not been described for Latin American population. To describe normal renal length (RL) by ultrasonography in a group of Mexican adults. Ultrasound measure of RL in 153 healthy Mexican adults stratified by age. Describe the association of RL to several anthropometric variables. A total of 77 males and 76 females were scanner. The average age for the group was 44.12 +/- 15.44 years. The mean weight, body mass index (BMI) and height were 68.87 +/- 11.69 Kg, 26.77 +/- 3.82 kg/m2 and 160 +/- 8.62 cm respectively. Dividing the population by gender, showed a height of 166 +/- 6.15 cm for males and 154.7 +/- 5.97 cm for females (p =0.000). Left renal length (LRL) in the whole group was 105.8 +/- 7.56 mm and right renal length (RRL) was 104.3 +/- 6.45 mm (p = 0.000.) The LRL for males was 107.16 +/- 6.97 mm and for females was 104.6 +/- 7.96 mm. The average RRL for males was 105.74 +/- 5.74 mm and for females 102.99 +/- 6.85 mm (p = 0.008.) We noted that RL decreased with age and the rate of decline accelerates alter 60 years of age. Both lengths correlated significantly and positively with weight, BMI and height. The RL was significantly larger in males than in females in both kidneys (p = 0.036) in this Mexican population. Renal length declines after 60 years of age and specially after 70 years.

  10. MixedNotes

    DEFF Research Database (Denmark)

    Jokela, Tero; Lucero, Andrés

    2014-01-01

    Affinity Diagramming is a technique to organize and make sense of qualitative data. It is commonly used in Contextual Design and HCI research. However, preparing notes for and building an Affinity Diagram remains a laborious process, with a wide variety of different approaches and practices....... In this paper, we present MixedNotes, a novel technique to prepare physical paper notes for Affinity Diagramming, and a software tool to support this technique. The technique has been tested with large real-life Affinity Diagrams with overall positive results....

  11. Self-assembling block copolymer systems involving competing length scales : A route toward responsive materials

    NARCIS (Netherlands)

    Nap, R; Erukhimovich, [No Value; ten Brinke, G; Erukhimovich, Igor

    2004-01-01

    The phase behavior of block copolymers melts involving competing length scales, i.e., able to microphase separate on two different length scales, is theoretically investigated using a self-consistent field approach. The specific block copolymers studied consist of a linear A-block linked to an

  12. 10th International School of Materials Science and Technology : Intercalation in Layered Materials "Ettore Majorana"

    CERN Document Server

    1986-01-01

    This volume is prepared from lecture notes for the course "Intercalation in Layered Materials" which was held at the Ettore Majorana Centre for Scientific Culture at Erice, Sicily in July, 1986, as part of the International School of Materials Science and Tech­ nology. The course itself consisted of formal tutorial lectures, workshops, and informal discussions. Lecture notes were prepared for the formal lectures, and short summaries of many of the workshop presentations were prepared. This volume is based on these lecture notes and research summaries. The material is addressed to advanced graduate students and postdoctoral researchers and assumes a background in basic solid state physics. The goals of this volume on Intercalation in Layered Materials include an introduc­ tion to the field for potential new participants, an in-depth and broad exposure for stu­ dents and young investigators already working in the field, a basis for cross-fertilization between workers on various layered host materials...

  13. Note Launchers: Promoting Active Reading of Mathematics Textbooks

    Science.gov (United States)

    Helms, Josh W.; Helms, Kimberly Turner

    2010-01-01

    Note launchers, an instructor-designed reading guide, model how to select, decide, and focus upon what textbook material is important to learn. Reading guides are specially-designed study aids that can steer students through difficult parts of assigned readings (Bean, 1996) while encouraging advance preparation. As an example of a reading guide,…

  14. Transfers from intensive care unit to hospital ward: a multicentre textual analysis of physician progress notes.

    Science.gov (United States)

    Brown, Kyla N; Leigh, Jeanna Parsons; Kamran, Hasham; Bagshaw, Sean M; Fowler, Rob A; Dodek, Peter M; Turgeon, Alexis F; Forster, Alan J; Lamontagne, Francois; Soo, Andrea; Stelfox, Henry T

    2018-01-28

    Little is known about documentation during transitions of patient care between clinical specialties. Therefore, we examined the focus, structure and purpose of physician progress notes for patients transferred from the intensive care unit (ICU) to hospital ward to identify opportunities to improve communication breaks. This was a prospective cohort study in ten Canadian hospitals. We analyzed physician progress notes for consenting adult patients transferred from a medical-surgical ICU to hospital ward. The number, length, legibility and content of notes was counted and compared across care settings using mixed-effects linear regression models accounting for clustering within hospitals. Qualitative content analyses were conducted on a stratified random sample of 32 patients. A total of 447 patient medical records that included 7052 progress notes (mean 2.1 notes/patient/day 95% CI 1.9-2.3) were analyzed. Notes written by the ICU team were significantly longer than notes written by the ward team (mean lines of text 21 vs. 15, p notes; mean agreement of patient issues was 42% [95% CI 31-53%]. Qualitative analyses identified eight themes related to focus (central point - e.g., problem list), structure (organization, - e.g., note-taking style), and purpose (intention - e.g., documentation of patient course) of the notes that varied across clinical specialties and physician seniority. Important gaps and variations in written documentation during transitions of patient care between ICU and hospital ward physicians are common, and include discrepancies in documentation of patient information.

  15. Potential change in flaw geometry of an initially shallow finite-length surface flaw during a pressurized-thermal-shock transient

    International Nuclear Information System (INIS)

    Shum, D.K.; Bryson, J.W.; Merkle, J.G.

    1993-09-01

    This study presents preliminary estimates on whether an shallow, axially oriented, inner-surface finite-length flaw in a PWR-RPV would tend to elongate in the axial direction and/or deepen into the wall of the vessel during a postulated PTS transient. Analysis results obtained based on the assumptions of (1) linear-elastic material response, and (2) cladding with same toughness as the base metal, indicate that a nearly semicircular flaw would likely propagate in the axial direction followed by propagation into the wall of the vessel. Note that these results correspond to initiation within the lower-shelf fracture toughness temperature range, and that their general validity within the lower-transition temperature range remains to be determined. The sensitivity of the numerical results aid conclusions to the following analysis assumptions are evaluated: (1) reference flaw geometry along the entire crack front and especially within the cladding region; (2) linear-elastic vs elastic-plastic description of material response; and (3) base-material-only vs bimaterial cladding-base vessel-model assumption. The sensitivity evaluation indicates that the analysis results are very sensitive to the above assumptions

  16. Short fetal leukocyte telomere length and preterm prelabor rupture of the membranes.

    Directory of Open Access Journals (Sweden)

    Ramkumar Menon

    Full Text Available BACKGROUND: Rupture of the fetal membranes is a common harbinger of imminent labor and delivery. Telomere shortening is a surrogate for oxidative stress (OS and senescence. Fetal leukocyte and placental membrane DNA telomere lengths were evaluated to determine their association with preterm prelabor rupture of the membranes (pPROM or spontaneous preterm births with intact membranes (PTB, compared to term birth. METHODS: Telomere lengths were quantified in cord blood leukocytes (n = 133 from three major groups: 1 pPROM (n = 28, 2 PTB (n = 69 and 3 uncomplicated full term births (controls, n = 35, using real-time quantitative PCR. Placental membrane specimens (n = 18 were used to correlate fetal leukocyte and placental telomere lengths. Telomere length differences among the groups were analyzed by ANOVA. Pearson correlation coefficients determined relationships between leukocyte and placental membrane telomere lengths. RESULTS: In pregnancies with intact membranes, fetal leukocyte telomere length was inversely proportional to gestational age. The mean telomere length decreased as gestation progressed, with the shortest at term. pPROM had telomere lengths (9962 ± 3124 bp that were significantly shorter than gestational age-matched PTB (11546 ± 4348 bp, p = 0.04, but comparable to term births (9011 ± 2497 bp, p = 0.31. Secondary analyses revealed no effects of race (African American vs. Caucasian or intraamniotic infection on telomere length. A strong Pearson's correlation was noted between fetal leukocyte and placental membrane telomere lengths (ρ = 0.77; p<0.01. CONCLUSIONS: Fetal leukocyte telomere length is reduced in pPROM compared to PTB but is similar to term births. pPROM represents a placental membrane disease likely mediated by OS-induced senescence.

  17. Accessible triple-phase boundary length: A performance metric to account for transport pathways in heterogeneous electrochemical materials

    Science.gov (United States)

    Nakajo, A.; Cocco, A. P.; DeGostin, M. B.; Peracchio, A. A.; Cassenti, B. N.; Cantoni, M.; Van herle, J.; Chiu, W. K. S.

    2016-09-01

    The performance of materials for electrochemical energy conversion and storage depends upon the number of electrocatalytic sites available for reaction and their accessibility by the transport of reactants and products. For solid oxide fuel/electrolysis cell materials, standard 3-D measurements such as connected triple-phase boundary (TPB) length and effective transport properties partially inform on how local geometry and network topology causes variability in TPB accessibility. A new measurement, the accessible TPB, is proposed to quantify these effects in detail and characterize material performance. The approach probes the reticulated pathways to each TPB using an analytical electrochemical fin model applied to a 3-D discrete representation of the heterogeneous structure provided by skeleton-based partitioning. The method is tested on artificial and real structures imaged by 3-D x-ray and electron microscopy. The accessible TPB is not uniform and the pattern varies depending upon the structure. Connected TPBs can be even passivated. The sensitivity to manipulations of the local 3-D geometry and topology that standard measurements cannot capture is demonstrated. The clear presence of preferential pathways showcases a non-uniform utilization of the 3-D structure that potentially affects the performance and the resilience to alterations due to degradation phenomena. The concepts presented also apply to electrochemical energy storage and conversion devices such as other types of fuel cells, electrolyzers, batteries and capacitors.

  18. Revising Lecture Notes: How Revision, Pauses, and Partners Affect Note Taking and Achievement

    Science.gov (United States)

    Luo, Linlin; Kiewra, Kenneth A.; Samuelson, Lydia

    2016-01-01

    Note taking has been categorized as a two-stage process: the recording of notes and the review of notes. We contend that note taking might best involve a three-stage process where the missing stage is revision. This study investigated the benefits of revising lecture notes and addressed two questions: First, is revision more effective than…

  19. Determination of thermal neutrons diffusion length in graphite

    International Nuclear Information System (INIS)

    Garcia Fite, J.

    1959-01-01

    The diffusion length of thermal neutrons in graphite using the less possible quantity of material has been determined. The proceeding used was the measurement in a graphite pile which has a punctual source of rapid neutrons inside surrounded by a reflector medium (paraffin or water). The measurement was done in the following conditions: a) introducing an aluminium plate between both materials. b) Introducing a cadmium plate between both materials. (Author) 91 refs

  20. Femtosecond laser effect on the self-sealing properties of the corneal incision of various lengths and profile (experimental trial

    Directory of Open Access Journals (Sweden)

    Yulduz Shavkatovna Nizametdinova

    2015-06-01

    Full Text Available An experimental investigation was carried out to study self-sealing properties of corneal incisions of different profile and length carried out with femtosecond laser Victus (Technolas Perfect Vision/Bausch&Lomb. Using femtosecond laser for this purpose allows creating corneal incisions of high precision and predictability. Reproducibility and standardization of the incision profile and length are an advantage of this technology. Obtained results showed that single-profile incisions are less stable and safe when compared to multi-profile ones. It was noted that incision length increase promotes its self-sealing properties.

  1. Chemical theory and modelling through density across length scales

    International Nuclear Information System (INIS)

    Ghosh, Swapan K.

    2016-01-01

    One of the concepts that has played a major role in the conceptual as well as computational developments covering all the length scales of interest in a number of areas of chemistry, physics, chemical engineering and materials science is the concept of single-particle density. Density functional theory has been a versatile tool for the description of many-particle systems across length scales. Thus, in the microscopic length scale, an electron density based description has played a major role in providing a deeper understanding of chemical binding in atoms, molecules and solids. Density concept has been used in the form of single particle number density in the intermediate mesoscopic length scale to obtain an appropriate picture of the equilibrium and dynamical processes, dealing with a wide class of problems involving interfacial science and soft condensed matter. In the macroscopic length scale, however, matter is usually treated as a continuous medium and a description using local mass density, energy density and other related property density functions has been found to be quite appropriate. The basic ideas underlying the versatile uses of the concept of density in the theory and modelling of materials and phenomena, as visualized across length scales, along with selected illustrative applications to some recent areas of research on hydrogen energy, soft matter, nucleation phenomena, isotope separation, and separation of mixture in condensed phase, will form the subject matter of the talk. (author)

  2. Lecture notes: string theory and zeta-function

    Energy Technology Data Exchange (ETDEWEB)

    Toppan, Francesco [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil). E-mail: toppan@cbpf.br

    2001-11-01

    These lecture notes are based on a revised and LaTexed version of the Master thesis defended at ISAS. The research part being omitted, they included a review of the bosonic closed string a la Polyakov and of the one-loop background field method of quantisation defined through the zeta-function. In an appendix some basic features of the Riemann zeta-function are also reviewed. The pedagogical aspects of the material here presented are particularly emphasized. These notes are used, together with the Scherk's article in Rev. Mod. Phys. and the first volume of the Polchinski book, for the mini-course on String Theory (16-hours of lectures) held at CBPF. In this course the Green-Schwarz-Witten two-volumes book is also used for consultative purposes. (author)

  3. Research Note:

    DEFF Research Database (Denmark)

    Behuria, Pritish; Buur, Lars; Gray, Hazel

    2017-01-01

    its core conceptual and methodological features. This Research Note starts by setting out our understanding of political settlements and provides an overview of existing political settlements literature on African countries. The note then explores how the key concept of ‘holding power’ has been...

  4. New methods of magnet-based instrumentation for NOTES.

    Science.gov (United States)

    Magdeburg, Richard; Hauth, Daniel; Kaehler, Georg

    2013-12-01

    Laparoscopic surgery has displaced open surgery as the standard of care for many clinical conditions. NOTES has been described as the next surgical frontier with the objective of incision-free abdominal surgery. The principal challenge of NOTES procedures is the loss of triangulation and instrument rigidity, which is one of the fundamental concepts of laparoscopic surgery. To overcome these problems necessitates the development of new instrumentation. material and methods: We aimed to assess the use of a very simple combination of internal and external magnets that might allow the vigorous multiaxial traction/counter-traction required in NOTES procedures. The magnet retraction system consisted of an external magnetic assembly and either small internal magnets attached by endoscopic clips to the designated tissue (magnet-clip-approach) or an endoscopic grasping forceps in a magnetic deflector roll (magnet-trocar-approach). We compared both methods regarding precision, time and efficacy by performing transgastric partial uterus resections with better results for the magnet-trocar-approach. This proof-of-principle animal study showed that the combination of external and internal magnets generates sufficient coupling forces at clinically relevant abdominal wall thicknesses, making them suitable for use and evaluation in NOTES procedures, and provides the vigorous multiaxial traction/counter-traction required by the lack of additional abdominal trocars.

  5. A note on notes: note taking and containment.

    Science.gov (United States)

    Levine, Howard B

    2007-07-01

    In extreme situations of massive projective identification, both the analyst and the patient may come to share a fantasy or belief that his or her own psychic reality will be annihilated if the psychic reality of the other is accepted or adopted (Britton 1998). In the example of' Dr. M and his patient, the paradoxical dilemma around note taking had highly specific transference meanings; it was not simply an instance of the generalized human response of distracted attention that Freud (1912) had spoken of, nor was it the destabilization of analytic functioning that I tried to describe in my work with Mr. L. Whether such meanings will always exist in these situations remains a matter to be determined by further clinical experience. In reopening a dialogue about note taking during sessions, I have attempted to move the discussion away from categorical injunctions about what analysis should or should not do, and instead to foster a more nuanced, dynamic, and pair-specific consideration of the analyst's functioning in the immediate context of the analytic relationship. There is, of course, a wide variety of listening styles among analysts, and each analyst's mental functioning may be affected differently by each patient whom the analyst sees. I have raised many questions in the hopes of stimulating an expanded discussion that will allow us to share our experiences and perhaps reach additional conclusions. Further consideration may lead us to decide whether note taking may have very different meanings for other analysts and analyst-patient pairs, and whether it may serve useful functions in addition to the one that I have described.

  6. A higher derivative view of the arc length and area actions

    International Nuclear Information System (INIS)

    Zoller, D.

    1991-01-01

    Higher derivative versions of the arc length and area actions are presented. The higher derivative theories are equivalent with the corresponding lower derivative theories in absence of interactions. The extra degrees of freedom associated with the higher derivatives are pure gauge due to a hidden reparametrization invariance these theories possess. The extra degrees of freedom are no longer pure gauge in the presence of background fields and the equivalence no longer holds. A string version of Wigner's continuous spin particle is also noted

  7. Production of carbonaceous materials with various lengths in small spheroidal fullerenes and long CNTs by tunable multi-walled carbon nanotube cutting

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Hoi; Shin, Ueon Sang [Dankook University, Cheonan (Korea, Republic of)

    2016-10-15

    Tunable cutting of multi-walled carbon nanotubes (CNTs) using high pressure homogenizer and/or HNO{sub 3}/H{sub 2}SO{sub 4} solution was accomplished, resulting in the production of short CNTs with minimum length of 35 nm. Field emission scanning electron microscopy (FE-SEM) and Zeta sizer analysis showed significant reduction of CNT length from this tunable cutting (e.g. from long and entangled pristine CNTs at about 20 μm to ≥1000 nm, ⁓400 nm, ⁓200 nm, and ⁓100 nm via high pressure jet-spraying cutting within 5 h, while chemical cutting process using greatly longer hours (48 h) showed a reduction only to about 1000 nm). When CNT sample of average 1000 nm length previously shortened by HNO{sub 3}/H{sub 2}SO{sub 4} was subjected to the high pressure jet-spraying cutting process, the reduction progressed faster (≤1 h), producing ≥35 nm. Fourier transform infrared spectra and thermogravimetric analysis (TGA) indicated restricted formation of hydrophilic functional groups such as carboxylic group and hydroxyl group in the high pressure jet-spraying cutting, whereas an intensive formation of hydrophilic functional groups on the surface of shortened CNT samples was found after chemical cutting. Such short CNT samples would fulfill the requirements for carbonaceous materials with various lengths in small spheroidal fullerenes and long CNTs. The short CNTs produced are promising for scientific and technological applications in many fields such as electronics, diagnostics, pharmaceuticals, biomedical engineering, and environmental or energy industries.

  8. Guidance notes : safe practice for the use of nuclear density meters

    International Nuclear Information System (INIS)

    2000-06-01

    These 'Guidance notes' have been written to provide information for owners and users on the safe care and use of instruments containing radioactive materials used for the measurement of moisture content and/or density of materials. They give practical guidance on compliance with the requirements of radiation protection legislation and the 'Code of safe practice for the use of nuclear density meters, NRL C15'. Some of these instruments have been known as 'soil moisture gauges' and others as 'nuclear density meters' or just 'NDMs'. For simplicity, these 'Guidance notes' will follow industry terminology and use the term 'nuclear density meter'. Some parts of these 'Guidance notes' and of the 'Code, NRL C15' are relevant for users of asphalt gauges containing radioactive sources. These are normally laboratory bench instruments, and are not portable field instruments. Nevertheless, the radioactive sources used are similar to those used for moisture measurement and the safety implications are similar. The units of measurement of radioactivity and radiation dose are discussed in Appendix 1. Appendix 2 contains consent application forms while sample transport forms can be found in Appendix 3. (author). 10 refs

  9. Notes on Japanese Rhizocephala, with description of two new species

    NARCIS (Netherlands)

    Boschma, H.

    1935-01-01

    The following notes are based upon material of parasites on two Crustaceans from Japan, viz., Pachygrapsus crassipes Randall and Petrolisthes japonicus de Haan 1). Each of these two species may be infested by two different species of Rhizocephala: on Pachygrapsus crassipes occur the parasites

  10. Open Oncology Notes: A Qualitative Study of Oncology Patients' Experiences Reading Their Cancer Care Notes.

    Science.gov (United States)

    Kayastha, Neha; Pollak, Kathryn I; LeBlanc, Thomas W

    2018-04-01

    Electronic medical records increasingly allow patients access to clinician notes. Although most believe that open notes benefits patients, some suggest negative consequences. Little is known about the experiences of patients with cancer reading their medical notes; thus we aimed to describe this qualitatively. We interviewed 20 adults with metastatic or incurable cancer receiving cancer treatment. The semistructured qualitative interviews included four segments: assessing their overall experience reading notes, discussing how notes affected their cancer care experiences, reading a real note with the interviewer, and making suggestions for improvement. We used a constant comparison approach to analyze these qualitative data. We found four themes. Patients reported that notes resulted in the following: (1) increased comprehension; (2) ameliorated uncertainty, relieved anxiety, and facilitated control; (3) increased trust; and (4) for a subset of patients, increased anxiety. Patients described increased comprehension because notes refreshed their memory and clarified their understanding of visits. This helped mitigate the unfamiliarity of cancer, addressing uncertainty and relieving anxiety. Notes facilitated control, empowering patients to ask clinicians more questions. The transparency of notes also increased trust in clinicians. For a subset of patients, however, notes were emotionally difficult to read and raised concerns. Patients identified medical jargon and repetition in notes as areas for improvement. Most patients thought that reading notes improved their care experiences. A small subset of patients experienced increased distress. As reading notes becomes a routine part of the patient experience, physicians might want to elicit and address concerns that arise from notes, thereby further engaging patients in their care.

  11. Mission climate note n.7, November 2005; Mission climat note d'etude n. 7, novembre 2005

    Energy Technology Data Exchange (ETDEWEB)

    Dominicis, A. de

    2005-07-01

    The year 2005 was the year of the implementing of the CO{sub 2} quotas market and the implementing of the kyoto protocol after the ratification by Russia. This context confirmed the presence of a 'carbon finance' based on new financial products: the CO{sub 2} actives or carbon credits which materialize the emissions reductions and exist on the new markets. This note presents the main points of these markets: the purchase funds implementing, the investments and the purchase mechanisms management. (A.L.B.)

  12. Effects of Note-Taking Training on Reading Comprehension and Recall

    Science.gov (United States)

    Rahmani, Mina; Sadeghi, Karim

    2011-01-01

    The present study examined the process and product effects of note-taking strategy training on Iranian EFL learners' comprehension and retention of written material, with gender as a moderating variable. Intermediate undergraduate EFL learners (N = 108) were assigned to experimental and control groups. The Experimental (intervention) Group…

  13. Multi Length Scale Finite Element Design Framework for Advanced Woven Fabrics

    Science.gov (United States)

    Erol, Galip Ozan

    Woven fabrics are integral parts of many engineering applications spanning from personal protective garments to surgical scaffolds. They provide a wide range of opportunities in designing advanced structures because of their high tenacity, flexibility, high strength-to-weight ratios and versatility. These advantages result from their inherent multi scale nature where the filaments are bundled together to create yarns while the yarns are arranged into different weave architectures. Their highly versatile nature opens up potential for a wide range of mechanical properties which can be adjusted based on the application. While woven fabrics are viable options for design of various engineering systems, being able to understand the underlying mechanisms of the deformation and associated highly nonlinear mechanical response is important and necessary. However, the multiscale nature and relationships between these scales make the design process involving woven fabrics a challenging task. The objective of this work is to develop a multiscale numerical design framework using experimentally validated mesoscopic and macroscopic length scale approaches by identifying important deformation mechanisms and recognizing the nonlinear mechanical response of woven fabrics. This framework is exercised by developing mesoscopic length scale constitutive models to investigate plain weave fabric response under a wide range of loading conditions. A hyperelastic transversely isotropic yarn material model with transverse material nonlinearity is developed for woven yarns (commonly used in personal protection garments). The material properties/parameters are determined through an inverse method where unit cell finite element simulations are coupled with experiments. The developed yarn material model is validated by simulating full scale uniaxial tensile, bias extension and indentation experiments, and comparing to experimentally observed mechanical response and deformation mechanisms. Moreover

  14. A note on a perfect simulation algorithm for marked Hawkes processes

    DEFF Research Database (Denmark)

    Møller, Jesper; Rasmussen, Jakob Gulddahl

    2004-01-01

    The usual straightforward simulation algorithm for (marked or unmarked) Hawkes processes suffers from edge effect. In this note we describe a perfect simulation algorithm which is partly derived as in Brix and Kendall (2002) and partly using upper and lower processes as in the Propp......-Wilson algorithm (1996), or rather as in the dominated CFTP algorithm by Kendall and Moller (2000). Various monotonicity properties and approximations of the cumulative distribution function for the length of a so-called cluster in a marked Hawkes process play an important role....

  15. 10 CFR 2.1003 - Availability of material.

    Science.gov (United States)

    2010-01-01

    ..., computer programs and codes, field notes, laboratory notes, maps, diagrams and photographs, which have been...; (xiv) Graphs, plots, strip charts, sketches; (xv) Descriptive material related to the information...

  16. 1. On note taking.

    Science.gov (United States)

    Plaut, Alfred B J

    2005-02-01

    In this paper the author explores the theoretical and technical issues relating to taking notes of analytic sessions, using an introspective approach. The paper discusses the lack of a consistent approach to note taking amongst analysts and sets out to demonstrate that systematic note taking can be helpful to the analyst. The author describes his discovery that an initial phase where as much data was recorded as possible did not prove to be reliably helpful in clinical work and initially actively interfered with recall in subsequent sessions. The impact of the nature of the analytic session itself and the focus of the analyst's interest on recall is discussed. The author then describes how he modified his note taking technique to classify information from sessions into four categories which enabled the analyst to select which information to record in notes. The characteristics of memory and its constructive nature are discussed in relation to the problems that arise in making accurate notes of analytic sessions.

  17. What happens when patients can see their doctors' note? - the Open Notes movement

    OpenAIRE

    Mende, Susan

    2017-01-01

    Introduction:  The Open Notes movement represents a culture change, enabling patients’ access to their providers’ notes, thereby increasing transparency and patient engagement.Policy context, objective and highlights:  OpenNotes involves allowing patients on-line or hard copy access to their providers’ notes. The one-year initial pilot began in 2010 with twenty thousand patients and one hundred primary care physicians at three medical centers in the United States.  The pilot’s evaluation foun...

  18. Note Taking and Recall

    Science.gov (United States)

    Fisher, Judith L.; Harris, Mary B.

    1974-01-01

    To study the effect of note taking and opportunity for review on subsequent recall, 88 college students were randomly assigned to five treatment groups utilizing different note taking and review combinations. No treatment effects were found, although quality of notes was positively correlated with free recall an multiple-choice measures.…

  19. Composite materials with arbitrary geometry - computer analysis with MATMEC

    DEFF Research Database (Denmark)

    Nielsen, Lauge Fuglsang

    1999-01-01

    Text note for the Summer school on "Hydration and Microstructure of High Performance Concrete, held at Dept. Struct. Eng. and Materials, DTU.......Text note for the Summer school on "Hydration and Microstructure of High Performance Concrete, held at Dept. Struct. Eng. and Materials, DTU....

  20. Machinability of CAD-CAM materials.

    Science.gov (United States)

    Chavali, Ramakiran; Nejat, Amir H; Lawson, Nathaniel C

    2017-08-01

    Although new materials are available for computer-aided design and computer-aided manufacturing (CAD-CAM) fabrication, limited information is available regarding their machinability. The depth of penetration of a milling tool into a material during a timed milling cycle may indicate its machinability. The purpose of this in vitro study was to compare the tool penetration rate for 2 polymer-containing CAD-CAM materials (Lava Ultimate and Enamic) and 2 ceramic-based CAD-CAM materials (e.max CAD and Celtra Duo). The materials were sectioned into 4-mm-thick specimens (n=5/material) and polished with 320-grit SiC paper. Each specimen was loaded into a custom milling apparatus. The apparatus pushed the specimens against a milling tool (E4D Tapered 2016000) rotating at 40 000 RPM with a constant force of 0.98 N. After a 6-minute timed milling cycle, the length of each milling cut was measured with image analysis software under a digital light microscope. Representative specimens and milling tools were examined with scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy. The penetration rate of Lava Ultimate (3.21 ±0.46 mm/min) and Enamic (2.53 ±0.57 mm/min) was significantly greater than that of e.max CAD (1.12 ±0.32 mm/min) or Celtra Duo (0.80 ±0.21 mm/min) materials. SEM observations showed little tool damage, regardless of material type. Residual material was found on the tools used with polymer-containing materials, and wear of the embedding medium was seen on the tools used with the ceramic-based materials. Edge chipping was noted on cuts made in the ceramic-based materials. Lava Ultimate and Enamic have greater machinability and less edge chipping than e.max CAD and Celtra Duo. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  1. Notes in Colombian Herpetology, II Notes in Colombian Herpetology, II

    Directory of Open Access Journals (Sweden)

    Dunn Emmett Reid

    1944-03-01

    Full Text Available The Lizard Genus Echinosaura (Teiidae in Colombia / Notes on the habits of the Tadpole-Carrying Frog Hyloxalus granuliventris / A New Marsupian Frog (Gastrotheca from Colombia The Lizard Genus Echinosaura (Teiidae in Colombia / Notes on the habits of the Tadpole-Carrying Frog Hyloxalus granuliventris / A New Marsupian Frog (Gastrotheca from Colombia.

  2. Depletion length and space charge layer capacitance in doped semiconductor nanoshpere

    International Nuclear Information System (INIS)

    Nersesyan, S R; Petrosyan, S G

    2012-01-01

    The depletion length in a semiconductor nanosphere depends not only on the material parameters but on the nanosphere radius as well. For this reason, the depletion length does not present a universal characteristic length for all spherical interfaces. The difference from the standard flat model caused by the surface curvature is significant for a structure with the depletion length comparable to the radius of a nanosphere. We show that the depletion layer capacitance in a nanosphere becomes quite sensitive to the light intensity when, as a result of increasing optical generation rate, the surface potential barrier height is decreased and becomes very small. (paper)

  3. Mission climate note n.7, November 2005

    International Nuclear Information System (INIS)

    Dominicis, A. de

    2005-01-01

    The year 2005 was the year of the implementing of the CO 2 quotas market and the implementing of the kyoto protocol after the ratification by Russia. This context confirmed the presence of a 'carbon finance' based on new financial products: the CO 2 actives or carbon credits which materialize the emissions reductions and exist on the new markets. This note presents the main points of these markets: the purchase funds implementing, the investments and the purchase mechanisms management. (A.L.B.)

  4. Note Taking for Geography Students.

    Science.gov (United States)

    Kneale, Pauline E.

    1998-01-01

    Addresses geography students' questions about why, when, and how to take notes. Outlines a step-by-step process for taking notes from written sources and from class lectures. Discusses what types of notes are appropriate for various types of sources. Suggests some ideas for making notes useful for individual learning styles. (DSK)

  5. Effect of mitomycin-c-assisted sutureless trabeculectomy on keratometry and axial length

    Directory of Open Access Journals (Sweden)

    Anant Sharma

    2017-01-01

    Full Text Available Aim: Glaucoma is defined as chronic, progressive optic neuropathy caused by a group of ocular conditions, which leads to damage of the optic nerve with loss of visual function. This study was conducted to find out the changes in corneal curvature, axial length and intraocular pressure. Materials and Methods: The present study was conducted in the Department of Ophthalmology, S P Medical College and Associated Group of Hospitals, Bikaner. A total of fifty cases of either age- and sex-matched controls were selected for this study. These cases were divided into two groups: Group A (sutureless trabeculectomy with mitomycin-C [MMC] and Group B (sutureless trabeculectomy without MMC. Results: The mean post-operative intraocular pressure (IOP was lowered in MMC-treated eyes when compared to control at 1½ months. The IOP reduction was greater in the MMC-treated eyes (13.25 mmHg at 1½ months as compared to control Group B (16.9 mmHg at 1½ months. Comparing results with the present study, it was found that success rate in MMC-treated eyes was noted in 23 (92% individuals, in which complete success was in 22 (88% while qualified success in 1 (4% and qualified failure in 2 (8% with mean IOP of 13.2 mmHg at 1½ months, whereas in control group, success rate was noted in 19 (76% individuals, in which complete success was in 18 (72% and qualified success in 1 (4%, while qualified failure in 6 (24% with mean IOP of 16.9 mmHg at 1½ months after operation. Conclusion: Results of this study are in favour of intraoperative application of MMC during filtration surgery, especially in cases with high-risk failure.

  6. Notes on Well-Posed, Ensemble Averaged Conservation Equations for Multiphase, Multi-Component, and Multi-Material Flows

    International Nuclear Information System (INIS)

    Ray A. Berry

    2005-01-01

    ensemble averaging can also be used to produce the governing equation systems. In fact volume and time averaging can be viewed as special cases of ensemble averaging. Ensemble averaging is beginning to gain some notice, for example the general-purpose multi-material flow simulation code CFDLib under continuing developed at the Los Alamos National Laboratory [Kashiwa and Rauenzahn 1994] is based on an ensemble averaged formulation. The purpose of this short note is to give an introduction to the ensemble averaging methodology and to show how ensemble averaged balance equations and entropy inequality can be obtained from the microscopic balances. It then details some seven-equation, two-pressure, two-velocity hyperbolic, well-posed models for two-phase flows. Lastly, a simple example is presented of a model in which the flow consists of two barotropic fluids with no phase change in which an equilibrium pressure equation is obtained in the spirit of pressure-based methods of computational fluid dynamics

  7. Melanie Klein and Repression: an examination of some unpublished Notes of 1934.

    Science.gov (United States)

    Hinshelwood, R D

    2006-01-01

    Fifteen pages of unpublished Notes were found in the Melanie Klein Archives dating from early 1934, a crucial moment in Klein's development. She was at this time, 1934, moving away from child analysis, whilst also rethinking and revising her allegiance to Karl Abraham's theory of the phases of libidinal development. These Notes, entitled "Early Repression Mechanism," show Klein struggling to develop what became her characteristic theories of the depressive position and the paranoid-schizoid position. Although these Notes are precursors of the paper Klein gave later to the IPA Congress in 1934, they also show the origins of the emphasis she and her followers eventually gave to "splitting" rather than repression. The Notes give us an insight into the way that she worked clinically at the time. We see Klein's confidence develop as she diverged from the classical theories and technique. Her ideas were based on close attention to the detail of her clinical material, rather than attacking theoretical problems directly. The Notes show her method of struggling to her own conclusions, and they offer us a chance to grasp the roots of the subsequent controversy over Kleinian thought.

  8. Dynamic Length Metrology (DLM) for measurements with sub-micrometre uncertainty in a production environment

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Hansen, Hans Nørgaard; Hattel, Jesper Henri

    2016-01-01

    Conventional length metrology for traceable accurate measurements requires costly temperature controlled facilities, long waiting time for part acclimatisation, and separate part material characterisation. This work describes a method called Dynamic Length Metrology (DLM) developed to achieve sub...

  9. Glycogen with short average chain length enhances bacterial durability

    Science.gov (United States)

    Wang, Liang; Wise, Michael J.

    2011-09-01

    Glycogen is conventionally viewed as an energy reserve that can be rapidly mobilized for ATP production in higher organisms. However, several studies have noted that glycogen with short average chain length in some bacteria is degraded very slowly. In addition, slow utilization of glycogen is correlated with bacterial viability, that is, the slower the glycogen breakdown rate, the longer the bacterial survival time in the external environment under starvation conditions. We call that a durable energy storage mechanism (DESM). In this review, evidence from microbiology, biochemistry, and molecular biology will be assembled to support the hypothesis of glycogen as a durable energy storage compound. One method for testing the DESM hypothesis is proposed.

  10. Ultralong Radiative States in Hybrid Perovskite Crystals: Compositions for Submillimeter Diffusion Lengths

    KAUST Repository

    Alarousu, Erkki

    2017-08-29

    Organic-inorganic hybrid perovskite materials have recently evolved into the leading candidate solution-processed semiconductor for solar cells due to their combination of desirable optical and charge transport properties. Chief among these properties is the long carrier diffusion length, which is essential to optimizing the device architecture and performance. Herein, we used time-resolved photoluminescence (at low excitation fluence, 10.59 μJ·cm upon two-photon excitation), which is the most accurate and direct approach to measure the radiative charge carrier lifetime and diffusion lengths. Lifetimes of about 72 and 4.3 μs for FAPbBr and FAPbI perovskite single crystals have been recorded, presenting the longest radiative carrier lifetimes reported to date for perovskite materials. Subsequently, carrier diffusion lengths of 107.2 and 19.7 μm are obtained. In addition, we demonstrate the key role of the organic cation units in modulating the carrier lifetime and its diffusion lengths, in which the defect formation energies for FA cations are much higher than those with the MA ones.

  11. Thoughts & Views on the Gulf War. Facilitators Notes and Workbook.

    Science.gov (United States)

    Hollings, Rick; Berghoff, Beth K.

    This document presents a workbook and facilitator's notes designed for use with small groups or with individual students in secondary schools to help them cope with troubling events related to the Gulf War. The material contained in the workbook is designed to help students deal with each of seven stages that the mastery model sees individuals…

  12. Evaluation of adverse events noted in children receiving continuous infusions of dexmedetomidine in the intensive care unit.

    Science.gov (United States)

    Honey, Brooke L; Harrison, Donald L; Gormley, Andrew K; Johnson, Peter N

    2010-01-01

    Dexmedetomidine is an α(2)-adrenergic receptor agonist with sedative and analgesic effects in mechanically ventilated adults and children. Safety and efficacy data are limited in children. The purpose of this study is to retrospectively identify the incidence and types of adverse events noted in children receiving continuous infusions of dexmedetomidine and evaluate potential risk factors for adverse events. Between July 1, 2006, and July 31, 2007, data were collected on all children (events. The primary endpoint was the total number of adverse events noted, including: transient hypertension, hypotension, neurological manifestations, apnea, and bradycardia. Secondary endpoints included categorization of each type of adverse event and an assessment of risk factors. A logistic regression model was used to assess the relationship of adverse events with independent variables including length of ICU stay, cumulative dose, peak infusion rate, duration of therapy, PRISM III score, and bolus dose. Thirty-six patients received dexmedetomidine representing 41 infusions. The median age was 16 months (range, 0.1-204 months) and median PRISM III score was 2 (range, 0-18). Eighteen (43.9%) patients received a bolus dose of dexmedetomidine. The median cumulative dose (mcg/kg) and peak dose (mcg/kg/hr) were 8.5 (range, 2.2-193.7) and 0.5 (range, 0.2-0.7), respectively. Dexmedetomidine was continued for a median of 20 (range, 3-263) hours. Six (14.6%) patients were slowly tapered off the continuous infusions. Twenty-one adverse events were noted in 17 patients, including 4 neurologic manifestations. Fourteen patients required interventions for adverse events. ICU length of stay was the only independent risk factor (p=0.036) for development of adverse events. Several potential adverse events were noted with dexmedetomidine continuous infusions including possible neurological manifestations. Further studies are needed looking at adverse events associated with dexmedetomidine use in

  13. Prevalence of lattice degeneration and its relation to axial length in severe myopia.

    Science.gov (United States)

    Celorio, J M; Pruett, R C

    1991-01-15

    We studied 436 eyes of 218 patients with myopia of -6.00 diopters or more in both eyes. Of 218 patients, 72 (33.0%) had lattice degeneration of the retina. Among these 72 patients, lattice lesions were uniocular in 39 (54.2%) and binocular in 33 (45.8%). Of 105 males, 33 (31.4%) had lattice degeneration; of 113 females, 39 (34.5%) had lattice degeneration. Contrary to previously published data, we found an inverse relationship between axial length and the prevalence of lattice degeneration in severely myopic eyes. The greatest prevalence of lattice degeneration (63 of 154 eyes, 40.9%) was found in eyes with an axial length of 26.0 to 26.9 mm (-6.00 to -8.70 diopters), and the least prevalence of lattice degeneration (five of 71 eyes, 7.0%) was found in eyes with an axial length of 32.0 mm (-24.00 diopters) or greater. This may explain the observation that retinal detachment after cataract surgery has been noted more commonly among patients with moderate than severe myopia.

  14. Pollen of Sarawakodendron (Celastraceae) and some related genera, with notes on techniques

    NARCIS (Netherlands)

    Hou, Ding

    1969-01-01

    1. A simple technique for acetolysis of small quantities of polliniferous (herbarium) material is described and notes on pollen photomicrography are presented. 2. Pollen grains of Sarawakodendron and six related genera, consisting of twenty-nine mostly Malesian species, have been examined and

  15. Size-dependent elastic/inelastic behavior of enamel over millimeter and nanometer length scales.

    Science.gov (United States)

    Ang, Siang Fung; Bortel, Emely L; Swain, Michael V; Klocke, Arndt; Schneider, Gerold A

    2010-03-01

    The microstructure of enamel like most biological tissues has a hierarchical structure which determines their mechanical behavior. However, current studies of the mechanical behavior of enamel lack a systematic investigation of these hierarchical length scales. In this study, we performed macroscopic uni-axial compression tests and the spherical indentation with different indenter radii to probe enamel's elastic/inelastic transition over four hierarchical length scales, namely: 'bulk enamel' (mm), 'multiple-rod' (10's microm), 'intra-rod' (100's nm with multiple crystallites) and finally 'single-crystallite' (10's nm with an area of approximately one hydroxyapatite crystallite). The enamel's elastic/inelastic transitions were observed at 0.4-17 GPa depending on the length scale and were compared with the values of synthetic hydroxyapatite crystallites. The elastic limit of a material is important as it provides insights into the deformability of the material before fracture. At the smallest investigated length scale (contact radius approximately 20 nm), elastic limit is followed by plastic deformation. At the largest investigated length scale (contact size approximately 2 mm), only elastic then micro-crack induced response was observed. A map of elastic/inelastic regions of enamel from millimeter to nanometer length scale is presented. Possible underlying mechanisms are also discussed. (c) 2009 Elsevier Ltd. All rights reserved.

  16. VA OpenNotes: exploring the experiences of early patient adopters with access to clinical notes.

    Science.gov (United States)

    Nazi, Kim M; Turvey, Carolyn L; Klein, Dawn M; Hogan, Timothy P; Woods, Susan S

    2015-03-01

    To explore the experience of early patient adopters who accessed their clinical notes online using the Blue Button feature of the My HealtheVet portal. A web-based survey of VA patient portal users from June 22 to September 15, 2013. 33.5% of respondents knew that clinical notes could be viewed, and nearly one in four (23.5%) said that they had viewed their notes at least once. The majority of VA Notes users agreed that accessing their notes will help them to do a better job of taking medications as prescribed (80.1%) and be better prepared for clinic visits (88.6%). Nine out of 10 users agreed that use of visit notes will help them understand their conditions better (91.8%), and better remember the plan for their care (91.9%). In contrast, 87% disagreed that VA Notes will make them worry more, and 88.4% disagreed that access to VA Notes will be more confusing than helpful. Users who had either contacted their provider or healthcare team (11.9%) or planned to (13.5%) primarily wanted to learn more about a health issue, medication, or test results (53.7%). Initial assessment of the patient experience within the first 9 months of availability provides evidence that patients both value and benefit from online access to clinical notes. These findings are congruent with OpenNotes study findings on a broader scale. Additional outreach and education is needed to enhance patient awareness. Healthcare professionals should author notes keeping in mind the opportunity patient access presents for enhanced communication. © The Author 2014. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Materials Education: Opportunities over a Lifetime

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Iver E.; Schwartz, Lyle H.; Faber, Katherine T.; Cargill III, G. Slade; Houston, Betsy

    2003-10-28

    A report, in the form of abbreviated notes, of the 17th Biennial Conference on National Materials Policy ''Materials Education: Opportunities over a Lifetime'' held May 20-21, 2002 in College Park, MD, sponsored by the Federation of Materials Societies and the University Materials Council.

  18. Experimental investigation of span length for flexural test of fiber reinforced polymer composite laminates

    Directory of Open Access Journals (Sweden)

    Akhil Mehndiratta

    2018-01-01

    Full Text Available Testing and evaluation of mechanical properties for FRP (Fiber Reinforced Polymer composite parts play a significant role to qualify it for the end use. Among the mechanical properties, the flexural strength is significant and vital as it may vary with specimen depth, temperature and the test span length. The flexural strength varies for different materials with varying the test span length hence the current work aims to find an optimum span length to test flexural strength for the specimens made of Glass (7781, EC9756 and Carbon (HTA7, G801 prepreg materials. Experiments are conducted as per the ASTM Standard D 790 for flexural test by varying the span lengths to understand the behavior of the flexural strength and flexural modulus. The experimental data were compared with those obtained from the finite element program software Altair Hyper works 14.0. The results indicate that flexural modulus increases with the span length to a point and then it decreases. Thereby, an optimum span length can be obtained for testing flexural strength, which will be useful to the designers and the composite manufacturers to accomplish better standard testing procedures.

  19. Length of urethra in the Indian adult male population

    Directory of Open Access Journals (Sweden)

    Venkatesh Krishnamoorthy

    2012-01-01

    Full Text Available Objective: The urethral length has not been measured in the Indian population. Even the international literature in this arena is very sparse. This paper is an attempt to develop a simple anatomical database for urethral length. Materials and Methods: Between January 2010 and April 2011, the urethral lengths of 422 adult male patients who required catheterization as part of regular treatment at our hospital, were recorded after obtaining consent from the patients and from the scientific and ethics review boards of the institution. Patients with history of prostatic or urethral abnormalities were excluded. The balloon of a sterile Foley′s catheter was inflated using 10 cc of saline. The length from the junction of the balloon to the ′Y′ junction of the Foley was measured. The catheter was then passed into the bladder and re-inflated to same volume. The penis was gently straightened and the length of the catheter outside the penis was measured till the premarked point at the ′Y′ junction. Subtracting this from the original length gave the length of the urethra. Results: The mean length of the urethra was 17.55 + 1.42 cm with a range between 14 and 22.5 cm. Conclusions: Literature in which the length of the normal adult male urethra is recorded for a significant sample size is very scarce. Our data adds to basic anatomic information of the male urethra specific to the Indian population. Statistical Methods: Descriptive statistical analysis was performed. The non-linear regression analysis was employed to find the normative values of urethral length according to age class.

  20. Modelling length of hospital stay in motor victims

    Directory of Open Access Journals (Sweden)

    Mercedes Ayuso-Gutiérrez

    2015-03-01

    Full Text Available Objective. To analyze which socio-demographic and other factors related to motor injuries affect the length of hospital recovery stay. Materials and methods. In the study a sample of 17 932 motor accidents was used. All the crashes occurred in Spain between 2000 and 2007. Different regression models were fitted to data to identify and measure the impact of a set of explanatory regressors. Results. Time of hospital stay for men is on average 41% larger than for women. When the victim has a fracture as a consequence of the accident, the mean time of hospital stay is multiplied by five. Injuries located in lower extremities, the head and abdomen are associated with greater hospitalization lengths. Conclusions. Gender, age and type of victim, as well as the location and nature of injuries, are found to be factors that have significant impact on the expected length of hospital stay.

  1. Metallic materials for medical use

    OpenAIRE

    Illarionov Anatoly; Belikov Sergey; Grib Stella; Yurovskikh Artem

    2017-01-01

    This article provides a brief overview of the metallic materials used as implants in orthopedics, the alloying system and a complex of the physical-mechanical properties for metallic materials certified for medical use, as well as the advantages and drawbacks of using metallic materials as implants. Approaches to improve the quality of an implant made of metallic materials are noted.

  2. Polymeric Materials - introduction and degradation

    DEFF Research Database (Denmark)

    Kontogeorgis, Georgios

    1999-01-01

    These notes support the polymer part of the courses 91742 and 91762 (Materials and Corrosion/degradation of materials) taught in IFAKthey contain a short introduction on group contribution methods for estimating properties of polymers, polymer thermodynamics, viscoelasticity models as well...

  3. Microgravity Processing and Photonic Applications of Organic and Polymeric Materials

    Science.gov (United States)

    Frazier, Donald 0; Penn, Benjamin G.; Smith, David; Witherow, William K.; Paley, M. S.; Abdeldayem, Hossin A.

    1998-01-01

    In recent years, a great deal of interest has been directed toward the use of organic materials in the development of high-efficiency optoelectronic and photonic devices. There is a myriad of possibilities among organic which allow flexibility in the design of unique structures with a variety of functional groups. The use of nonlinear optical (NLO) organic materials such as thin-film waveguides allows full exploitation of their desirable qualities by permitting long interaction lengths and large susceptibilities allowing modest power input. There are several methods in use to prepare thin films, such as Langmuir-Blodgett (LB) and self-assembly techniques, vapor deposition, growth from sheared solution or melt, and melt growth between glass plates. Organics have many features that make Abstract: them desirable for use in optical devices such as high second- and third-order nonlinearities, flexibility of molecular design, and damage resistance to optical radiation. However, their use in devices has been hindered by processing difficulties for crystals and thin films. In this chapter, we discuss photonic and optoelectronic applications of a few organic materials and the potential role of microgravity on processing these materials. It is of interest to note how materials with second- and third-order nonlinear optical behavior may be improved in a diffusion-limited environment and ways in which convection may be detrimental to these materials. We focus our discussion on third-order materials for all-optical switching, and second-order materials for all-optical switching, and second-order materials for frequency conversion and electrooptics.

  4. SAFETY NOTES

    CERN Document Server

    TIS Secretariat

    2001-01-01

    Please note that the revisions of safety notes no 3 (NS 3 Rev. 2) and no 24 (NS 24 REV.) entitled respectively 'FIRE PREVENTION FOR ENCLOSED SPACES IN LARGE HALLS' and 'REMOVING UNBURIED ELV AND LVA ELECTRIC CONDUITS' are available on the web at the following urls: http://edmsoraweb.cern.ch:8001/cedar/doc.download?document_id=322811&version=1&filename=version_francaise.pdf http://edmsoraweb.cern.ch:8001/cedar/doc.download?document_id=322861&version=2&filename=version_francaise.pdf Paper copies can also be obtained from the TIS Divisional Secretariat, email tis.secretariat@cern.ch

  5. The length-weight and length-length relationships of bluefish, Pomatomus saltatrix (Linnaeus, 1766 from Samsun, middle Black Sea region

    Directory of Open Access Journals (Sweden)

    Melek Özpiçak

    2017-10-01

    Full Text Available In this study, length-weight relationship (LWR and length-length relationship (LLR of bluefish, Pomatomus saltatrix were determined. A total of 125 specimens were sampled from Samsun, the middle Black Sea in 2014 fishing season. Bluefish specimens were monthly collected from commercial fishing boats from October to December 2014. All captured individuals (N=125 were measured to the nearest 0.1 cm for total, fork and standard lengths. The weight of each fish (W was recorded to the nearest 0.01 g. According to results of analyses, there were no statistically significant differences between sexes in term of length and weight (P˃0.05. The minimum and maximum total, fork and standard lengths of bluefish ranged between 13.5-23.6 cm, 12.50-21.80 cm and 10.60-20.10 cm, respectively. The equation of length-weight relationship were calculated as W=0.008TL3.12 (r2>0.962. Positive allometric growth was observed for bluefish (b>3. Length-length relationship was also highly significant (P<0.001 with coefficient of determination (r2 ranging from 0.916 to 0.988.

  6. Nanometer scale materials - characterization and fabrication

    International Nuclear Information System (INIS)

    Murday, J.S.; Colton, R.J.; Rath, B.B.

    1993-01-01

    Materials and solid state scientists have made excellent progress in understanding material behavior in length scales from microns to meters. Below a micron, the lack of analytical prowess has been a deterrent. At the atomic scale, chemistry and atomic/molecular physics have also contributed significant understanding of matter. The maturity of these three communities, materials, solid state physics, atomic/molecular physics/chemistry, coupled with the development of analytical capability for nanometer-sized structures, promises to broaden our grasp of materials behavior into the last realm of unexplored size scales-nanometer. The motivation for this effort is driven both by the expectation of novel properties as well as by the potential solution to long standing technological issues. Critical scale lengths for many material properties fall in the nanometer range, examples include superconductor coherence lengths, electron inelastic mean free paths, electron wavelengths in solids, critical lengths for dislocation generation. Structures of nanometer size will undoubtedly show behavior unexpected from experience at the larger and smaller scales. Many technological problems such as adhesion, friction, corrosion, elasticity and fracture are believed to depend critically on nanometer scale phenomena. The millennia-old efforts to improve materials behavior have undoubtedly been slowed by our inability to 'observe' in this size range. (orig.)

  7. Employers' views on the fit note.

    Science.gov (United States)

    Kotze, E

    2014-12-01

    The fit note replaced the sick note in 2010. The statement of fitness for work (fit note) is expected to benefit the British economy by helping more people stay in work and prevent long-term sickness absence. Understanding and responding to employers' views on the fit note is key, in order for this goal to be achieved. To explore employers' views on the fit note. A qualitative study was undertaken and face-to-face interviews were conducted with participants representing employers from a variety of industries. There were 21 participants who were mainly human resources officers and line managers. Employers welcomed the introduction of the fit note and felt that it was an improvement on the sick note. The majority of employers felt the fit note had the potential to promote an earlier return to work, if used properly. The main problems reported were the completion of the fit notes and quality of advice received from general practitioners. Employers felt that the most helpful advice came from fit notes with information on the functional effects of the medical condition. Some employers found return to work decisions problematic. The fit note has the potential to promote an earlier return to work. In order for the fit note to achieve its aim, further understanding of the difficulties employers are having when making return to work decisions is important, in order to develop guidance to enable them to provide the practical support employees need to return to work sooner. © The Author 2014. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. The method to design the length of thin-wall flexible rotor

    International Nuclear Information System (INIS)

    Zhang Yue; Yao Zengzhong; Baigu Lafu

    2014-01-01

    Thin-wall flexible rotor is frequently used in rotating machinery. For this rotor the vibration is very complex under the working speed. So the composition design is very difficult. In this paper, for a thin-wall flexible rotor, the material and rotor diameter are determined from spatial structure, the working speed is determined from strength of the material, the first bending critical speed is determined from working speed, then the influence of length on the critical speed is researched. According to the influence of critical speed on the vibration, the length design method is researched, the design steps and methods are given, the safety margin of vibration is analysed. Design validity is established by test. The method is generally suitable for thin-wall flexible rotor. (authors)

  9. Oligonucleotide Length-Dependent Formation of Virus-Like Particles.

    Science.gov (United States)

    Maassen, Stan J; de Ruiter, Mark V; Lindhoud, Saskia; Cornelissen, Jeroen J L M

    2018-05-23

    Understanding the assembly pathway of viruses can contribute to creating monodisperse virus-based materials. In this study, the cowpea chlorotic mottle virus (CCMV) is used to determine the interactions between the capsid proteins of viruses and their cargo. The assembly of the capsid proteins in the presence of different lengths of short, single-stranded (ss) DNA is studied at neutral pH, at which the protein-protein interactions are weak. Chromatography, electrophoresis, microscopy, and light scattering data show that the assembly efficiency and speed of the particles increase with increasing length of oligonucleotides. The minimal length required for assembly under the conditions used herein is 14 nucleotides. Assembly of particles containing such short strands of ssDNA can take almost a month. This slow assembly process enabled the study of intermediate states, which confirmed a low cooperative assembly for CCMV and allowed for further expansion of current assembly theories. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. The Materiality of Research

    DEFF Research Database (Denmark)

    Meier, Ninna

    2016-01-01

    In this feature essay, Ninna Meier reflects on the materiality of the writing – and re-writing – process in academic research. She explores the ways in which our ever-accummulating thoughts come to form layers on the material objects in which we write our notes and discusses the pleasures of co-authorship....

  11. EndNote 7.0

    Directory of Open Access Journals (Sweden)

    Eapen Bell

    2006-01-01

    Full Text Available EndNote is a useful software for online literature search and efficient bibliography management. It helps to format the bibliography according to the citation style of each journal. EndNote stores references in a library file, which can be shared with others. It can connect to online resources like PubMed and retrieve search results as per the search criteria. It can also effortlessly integrate with popular word processors like MS Word. The Indian Journal of Dermatology, Venereology and Leprology website has a provision to import references to EndNote.

  12. The impact of note taking style and note availability at retrieval on mock jurors' recall and recognition of trial information.

    Science.gov (United States)

    Thorley, Craig; Baxter, Rebecca E; Lorek, Joanna

    2016-01-01

    Jurors forget critical trial information and what they do recall can be inaccurate. Jurors' recall of trial information can be enhanced by permitting them to take notes during a trial onto blank sheets of paper (henceforth called freestyle note taking). A recent innovation is the trial-ordered-notebook (TON) for jurors, which is a notebook containing headings outlining the trial proceedings and which has space beneath each heading for notes. In a direct comparison, TON note takers recalled more trial information than freestyle note takers. This study investigated whether or not note taking improves recall as a result of enhanced encoding or as a result of note access at retrieval. To assess this, mock jurors watched and freely recalled a trial video with one-fifth taking no notes, two-fifths taking freestyle notes and two-fifths using TONs. During retrieval, half of the freestyle and TON note takers could access their notes. Note taking enhanced recall, with the freestyle note takers and TON note takers without note access performing equally as well. Note taking therefore enhances encoding. Recall was greatest for the TON note takers with note access, suggesting a retrieval enhancement unique to this condition. The theoretical and applied implications of these findings are discussed.

  13. A note on "An economic order quantity (EOQ for items with imperfect quality and inspection errors"

    Directory of Open Access Journals (Sweden)

    Lie-Fern Hsu

    2012-08-01

    Full Text Available In a previously published paper by Khan et al. (2011 [Khan, M., Jaber, M.Y., & Bonney M. (2011. An economic order quantity (EOQ for items with imperfect quality and inspection errors, International Journal of Production Economics, 133, 113-118], we found that there is a contradiction between the cycle length and the holding cost per cycle. To obtain the cycle length, the authors assumed that the returned items from the market were replaced with good quality items. However, for the holding cost per cycle, the authors implicitly assumed that the returned items were not replaced by good quality items. In this note, we first point out the contradiction. Then we fix this flaw and develop a corrected EOQ.

  14. Damping coherent phase oscillations by means of path-length modulation

    International Nuclear Information System (INIS)

    Rees, J.R.

    1978-06-01

    Multi-bunch storage rings and synchrotrons are typically plagued by a tendency for the bunches to indulge in unstable coherent phase oscillations engendered by their electromagnetic interactions with the vacuum chamber. In many machines feedback systems have been used successfully to damp these oscillations using a signal proportional to the coherent phase motion or the concomitant energy motion to control an auxiliary longitudinal electric field. The purpose of this note is to describe an alternative feedback system which, using the same kind of a signal, modulates the path length of the orbit of the reference particle (the synchronous particle in the absence of coherent phase oscillations) in such a way as to damp coherent oscillations. 2 refs., 1 fig

  15. An Information Foraging Analysis of Note Taking and Note Sharing While Browsing Campaign Information

    DEFF Research Database (Denmark)

    Vatrapu, Ravi; Robertson, Scott

    2010-01-01

    In this paper, we present an experimental study of political information foraging in the context of e-voting. Participants were observed while searching and browsing the internet for campaign information in a mock-voting situation in three online note-taking conditions: No Notes, Private Notes...... with lack of scent, low value perception, and value depletion of information. Implications for the voter centered design of e-voting portals are discussed....

  16. Technical Note: Updated durability/composition relationships for Hanford high-level waste glasses

    International Nuclear Information System (INIS)

    Piepel, G.F.; Hartley, S.A.; Redgate, P.E.

    1996-03-01

    This technical note presents empirical models developed in FYI 995 to predict durability as functions of glass composition. Models are presented for normalized releases of B, Li, Na, and Si from the 7-day Product Consistency Test (PCT) applied to quenched and canister centerline cooled (CCC) glasses as well as from the 28-day Materials Characterization Center-1 (MCC-1) test applied to quenched glasses. Models are presented for Composition Variation Study (CVS) data from low temperature melter (LTM) studies (Hrma, Piepel, et al. 1994) and high temperature melter (HTM) studies (Vienna et al. 1995). The data used for modeling in this technical note are listed in Appendix A

  17. Lecture notes on diophantine analysis

    CERN Document Server

    Zannier, Umberto

    2014-01-01

    These lecture notes originate from a course delivered at the Scuola Normale in Pisa in 2006. Generally speaking, the prerequisites do not go beyond basic mathematical material and are accessible to many undergraduates. The contents mainly concern diophantine problems on affine curves, in practice describing the integer solutions of equations in two variables. This case historically suggested some major ideas for more general problems. Starting with linear and quadratic equations, the important connections with Diophantine Approximation are presented and Thue's celebrated results are proved in full detail. In later chapters more modern issues on heights of algebraic points are dealt with, and applied to a sharp quantitative treatment of the unit equation. The book also contains several Supplements, hinted exercises and an Appendix on recent work on heights.

  18. Effects of Note-Taking Instruction and Note-Taking Languages on College EFL Students' Listening Comprehension

    Science.gov (United States)

    Tsai-Fu, Tsai; Wu, Yongan

    2010-01-01

    Background: The effect of note-taking has been well-recognized by EFL educators. However, little empirical research has been done to investigate combined effects of note-taking instruction and note-taking language (whether in L1 or L2) in an acquisition-poor environment, where English is used as an instructional language yet the audience is…

  19. Bunch Length Measurements using Coherent Radiation

    CERN Document Server

    Ischebeck, Rasmus; Barnes, Christopher; Blumenfeld, Ian; Clayton, Chris; Decker, Franz Josef; Deng, Suzhi; Hogan, Mark; Huang Cheng Kun; Iverson, Richard; Johnson, Devon K; Krejcik, Patrick; Lu, Wei; Marsh, Kenneth; Oz, Erdem; Siemann, Robert; Walz, Dieter

    2005-01-01

    The accelerating field that can be obtained in a beam-driven plasma wakefield accelerator depends on the current of the electron beam that excites the wake. In the E-167 experiment, a peak current above 10kA will be delivered at a particle energy of 28GeV. The bunch has a length of a few ten micrometers and several methods are used to measure its longitudinal profile. Among these, autocorrelation of coherent transition radiation (CTR) is employed. The beam passes a thin metallic foil, where it emits transition radiation. For wavelengths greater than the bunch length, this transition radiation is emitted coherently. This amplifies the long-wavelength part of the spectrum. A scanning Michelson interferometer is used to autocorrelate the CTR. However, this method requires the contribution of many bunches to build an autocorrelation trace. The measurement is influenced by the transmission characteristics of the vacuum window and beam splitter. We present here an analysis of materials, as well as possible layouts ...

  20. Physicians’ Progress Notes

    DEFF Research Database (Denmark)

    Bansler, Jørgen; Havn, Erling C.; Mønsted, Troels

    2013-01-01

    in patient care, they have not dealt specifically with the role, structure, and content of the progress notes. As a consequence, CSCW research has not yet taken fully into account the fact that progress notes are coordinative artifacts of a rather special kind, an open-ended chain of prose texts, written...... sequentially by cooperating physicians for their own use as well as for that of their colleagues. We argue that progress notes are the core of the medical record, in that they marshal and summarize the overwhelming amount of data that is available in the modern hospital environment, and that their narrative...... format is uniquely adequate for the pivotal epistemic aspect of cooperative clinical work: the narrative format enables physicians to not only record ‘facts’ but also—by filtering, interpreting, organizing, and qualifying information—to make sense and act concertedly under conditions of uncertainty...

  1. The Effectiveness of Note-Taking on Reading Comprehension of Iranian EFL Learners

    Directory of Open Access Journals (Sweden)

    Farnoush Bahrami

    2017-10-01

    Full Text Available By taking notes students could save time for reading all textbooks for their exams or for their representations. Taking notes increases attention of students to read or heard materials, and this increases their comprehension. Thus, the present study is important because note-taking could help them to remember what they learnt, absolutely important information. The method used in this research was survey. The 40 Persian EFL learners were selected from a language institute in Karaj to participate in the present study. These learners were divided into two groups; one of them is experimental group (N=20 and the other one is control group (N=20. Pretest and post test were two instruments that were used to carry out this study, a pretest about skill of note-taking of passages of the lessons was used for both experimental and control group. This test consisted of 4 passages. The same test was administrated again as the post test for both groups by the end of the course to see the different conclusion between taking note of experimental group and control group. Reliability between 4 texts is in oscillation from 0.6 to 0.81 (from 0.6 upwards. Therefore this reliability was an acceptable one. To analyze data descriptive statistics (that was contained percentage, frequency and mean score and also inferential statistics (that was contained ANOVA, Pearson correlation, independent sample t-test, multivariate’s test, regression were carried out by using SPSS16 soft ware. The findings confirmed that note taking is effective in reading comprehension.

  2. Understanding Digital Note-Taking Practice for Visualization.

    Science.gov (United States)

    Willett, Wesley; Goffin, Pascal; Isenberg, Petra

    2015-05-13

    We present results and design implications from a study of digital note-taking practice to examine how visualization can support revisitation, reflection, and collaboration around notes. As digital notebooks become common forms of external memory, keeping track of volumes of content is increasingly difficult. Information visualization tools can help give note-takers an overview of their content and allow them to explore diverse sets of notes, find and organize related content, and compare their notes with their collaborators. To ground the design of such tools, we conducted a detailed mixed-methods study of digital note-taking practice. We identify a variety of different editing, organization, and sharing methods used by digital note-takers, many of which result in notes becoming "lost in the pile''. These findings form the basis for our design considerations that examine how visualization can support the revisitation, organization, and sharing of digital notes.

  3. Area, length and thickness conservation: Dogma or reality?

    Science.gov (United States)

    Moretti, Isabelle; Callot, Jean Paul

    2012-08-01

    The basic assumption of quantitative structural geology is the preservation of material during deformation. However the hypothesis of volume conservation alone does not help to predict past or future geometries and so this assumption is usually translated into bed length in 2D (or area in 3D) and thickness conservation. When subsurface data are missing, geologists may extrapolate surface data to depth using the kink-band approach. These extrapolations, preserving both thicknesses and dips, lead to geometries which are restorable but often erroneous, due to both disharmonic deformation and internal deformation of layers. First, the Bolivian Sub-Andean Zone case is presented to highlight the evolution of the concepts on which balancing is based, and the important role played by a decoupling level in enhancing disharmony. Second, analogue models are analyzed to test the validity of the balancing techniques. Chamberlin's excess area approach is shown to be on average valid. However, neither the length nor the thicknesses are preserved. We propose that in real cases, the length preservation hypothesis during shortening could also be a wrong assumption. If the data are good enough to image the decollement level, the Chamberlin excess area method could be used to compute the bed length changes.

  4. Influence of the gauge length on the accuracy of long-gauge sensors employed in monitoring of prismatic beams

    International Nuclear Information System (INIS)

    Glisic, Branko

    2011-01-01

    Depending on the geometric basis of measurement (gauge length), discrete strain sensors used in structural monitoring of civil engineering structures can be considered as short-gauge sensors or long-gauge sensors. Long-gauge sensors measure average strain over the gauge lengths and are used for global monitoring of structures, in particular, those built of inhomogeneous materials. However, the strain distribution along the sensor's gauge length may be nonlinear and the measured average strain value that is commonly attributed to the midpoint of the sensor may be different from the real value of strain at that point. Consequently, excessively long sensors may feature significant errors in measurement. However, short-gauge sensors are more susceptible to other types of measurement error, most notably, error caused by discontinuities (open cracks) distributed in the monitored material. Thus an optimum gauge length is to be found. The error in average strain measurement inherent to the sensor's gauge length introduced by the strain distribution and discontinuities in the monitored material is modelled for the most common applications met in civil engineering practice. The modelling takes into account the geometric properties of the monitored structure and various load cases. Guidelines for the selection of an appropriate gauge length are proposed, and tables for measurement error estimation are presented

  5. Noted

    Science.gov (United States)

    Nunberg, Geoffrey

    2013-01-01

    Considering how much attention people lavish on the technologies of writing--scroll, codex, print, screen--it's striking how little they pay to the technologies for digesting and regurgitating it. One way or another, there's no sector of the modern world that is not saturated with note-taking--the bureaucracy, the liberal professions, the…

  6. Variation of solvent scattering-length density small-angle neutron scattering as a means of determining structure of composite materials

    International Nuclear Information System (INIS)

    Hjelm, R.P.; Wampler, W.; Gerspacher, M.

    1994-01-01

    As part of our work on the, structure of composite materials we have been exploring the use of small-angle neutron scattering using the method of contrast variation to dissect the component form, structure and distribution. This approach has resulted in a new look at very old problem reinforcement of elastomers by carbon black. Using this approach we studied an experimental high surface area (HSA) carbon black and a gel of ''HSA-bound'' rubber in cyclohexane/deuterocyclohexane mixtures. HSA in cyclohexane is found to be short rodlike particle aggregates. The aggregates have a shell-core structure with a high density graphitic outer shell and an inner core of lower density amorphous carbon. The core is continuous throughout the carbon black aggregate, making the aggregate a stiff, integral unit. Contrast variation of swollen composite gels shows that there are two length scales in the gel structure. Above 10 Angstrom, scattering from carbon black predominates, and below 10 Angstrom the scattering is from both carbon black and the elastomer. The HSA in the composite is completely embedded in polyisoprene. An estimate of the carbon black structure factor shows strong exclusion of neighboring aggregates, probably from excluded volume effects. The surface structure of the carbon black is unaltered by the interactions with elastomer and appears smooth over length scales above about 10 Angstrom. These results show that contrast variation can provide information on composite structure that is not available by other means. This information relates to the reinforcement mechanism of elastomers by carbon blacks

  7. The length-weight and length-length relationships of bluefish, Pomatomus saltatrix (Linnaeus, 1766) from Samsun, middle Black Sea region

    OpenAIRE

    Özpiçak, Melek; Saygın, Semra; Polat, Nazmi

    2017-01-01

    In this study, length-weight relationship (LWR) and length-length relationship (LLR) of bluefish,Pomatomus saltatrix were determined. A total of 125 specimens were sampled from Samsun, themiddle Black Sea in 2014 fishing season. Bluefish specimens were monthly collected fromcommercial fishing boats from October to December 2014. All captured individuals (N=125) weremeasured to the nearest 0.1 cm for total, fork and standard lengths. The weight of each fish (W)was recorded to the nearest 0.01 ...

  8. Making Notes, Making Meaning.

    Science.gov (United States)

    Burke, Jim

    2002-01-01

    Introduces notetaking tools used successfully with English-as-a-second-language students and low-achieving high school freshmen. Provides an overview of each tool and explains how students use them to take notes when reading textbooks and articles. Notes these tools and academic habits have helped students succeed in their mainstream academic…

  9. A note on Fukui’s note

    Directory of Open Access Journals (Sweden)

    Tsai Cheng-Yu Edwin

    2015-12-01

    Full Text Available This commentary relates Fukui’s (2015 note on weak vs. strong generation to two aspects of quantification in Chinese: quantifier scope and the syntactic licensing conditions of noninterrogative wh-expressions. It is shown that the phenomena under discussion echo Fukui’s (2015 view that only strong generation allows for a deeper understanding of natural language and that dependencies are to be distinguished structurally.

  10. Molecules To Materials

    Indian Academy of Sciences (India)

    rials, Vo1.3, July 1998. Please Note in port 2. ... which such processes can be carried out efficiently are called. NLO materials. .... play in the world of photonics. Though .... A wide variety of modifications on the nitroaniline framework have been ...

  11. Notes on Piezoelectricity

    Energy Technology Data Exchange (ETDEWEB)

    Redondo, Antonio [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-02-03

    These notes provide a pedagogical discussion of the physics of piezoelectricity. The exposition starts with a brief analysis of the classical (continuum) theory of piezoelectric phenomena in solids. The main subject of the notes is, however, a quantum mechanical analysis. We first derive the Frohlich Hamiltonian as part of the description of the electron-phonon interaction. The results of this analysis are then employed to derive the equations of piezoelectricity. A couple of examples with the zinc blende and and wurtzite structures are presented at the end

  12. NASA Lewis Research Center's materials and structures division

    International Nuclear Information System (INIS)

    Weymueller, C.R.

    1976-01-01

    Research activities at the NASA Lewis Research Center on materials and structures are discussed. Programs are noted on powder metallurgy superalloys, eutectic alloys, dispersion strengthened alloys and composite materials. Discussions are included on materials applications, coatings, fracture mechanics, and fatigue

  13. Telomere length analysis.

    Science.gov (United States)

    Canela, Andrés; Klatt, Peter; Blasco, María A

    2007-01-01

    Most somatic cells of long-lived species undergo telomere shortening throughout life. Critically short telomeres trigger loss of cell viability in tissues, which has been related to alteration of tissue function and loss of regenerative capabilities in aging and aging-related diseases. Hence, telomere length is an important biomarker for aging and can be used in the prognosis of aging diseases. These facts highlight the importance of developing methods for telomere length determination that can be employed to evaluate telomere length during the human aging process. Telomere length quantification methods have improved greatly in accuracy and sensitivity since the development of the conventional telomeric Southern blot. Here, we describe the different methodologies recently developed for telomere length quantification, as well as their potential applications for human aging studies.

  14. The new bank note distribution system

    OpenAIRE

    Gerrit Bilkes

    1997-01-01

    In this article, the author outlines the recent changes made to the way Canada's bank notes are distributed. The new system allows financial institutions to exchange notes directly with one another at designated points across the country, rather than through Bank of Canada agencies, as was previously the case. The institutions communicate with the Bank of Canada through a computerized inventory-management system. Two Bank of Canada operations centres monitor note quality and supply new notes ...

  15. Suicide note themes and suicide prevention.

    Science.gov (United States)

    Foster, Tom

    2003-01-01

    The aim was to determine if suicide note themes might inform suicide prevention strategies. The themes of 42 suicide notes from the Northern Ireland Suicide Study (major psychological autopsy study) were examined. The commonest themes were "apology/shame" (74%), "love for those left behind" (60%), "life too much to bear" (48%), "instructions regarding practical affairs post-mortem" (36%), "hopelessness/nothing to live for" (21%) and "advice for those left behind" (21%). Notes of suicides with major unipolar depression were more likely than notes of suicides without major unipolar depression to contain the themes "instructions regarding practical affairs post-mortem" (67% versus 19%, p = 0.005) and "hopelessness/nothing to live for" (40% versus 11%, p = 0.049). Notes of suicides with a previous history of deliberate self-harm were less likely than notes of suicides without a history of deliberate self-harm to contain the theme "apology/shame" (58% versus 87%, p = 0.04). Notes of elderly suicides were more likely than non-elderly notes to contain the theme "burden to others" (40% versus 3%, p = 0.03). The fact that three quarters of suicide notes contained the theme "apology/shame" suggests that the deceased may have welcomed alternative solutions for their predicaments. Scrutiny of suicide note themes in the light of previous research findings suggests that cognitive therapy techniques, especially problem solving, may have an important role to play in suicide prevention and that potential major unipolar depressive (possibly less impulsive) suicides, in particular, may provide fertile ground for therapeutic intervention (physical and psychological). Ideally all primary care doctors and mental health professionals working with (potentially) suicidal people should be familiar with basic cognitive therapy techniques, especially problem solving skills training.

  16. Factors affecting length of hospital stay for people with spinal cord injuries at Kanombe military hospital, Rwanda

    Directory of Open Access Journals (Sweden)

    PB Bwanjugu

    2012-12-01

    Full Text Available In patients with spinal cord injuries increased length ofhospital stay is often as a result of secondary complications such as pressuresores, urinary tract infection and respiratory infection. An increased lengthof hospital stay was observed at Kanombe Military Hospital in Rwanda.The aim of this study was to determine specific factors affecting length ofhospital stay for individuals with spinal cord injuries at Kanombe MilitaryHospital in Rwanda. The records of 124 individuals with spinal cordinjuries who were discharged from the hospital between 1st January1996and 31st December 2007 were reviewed to collect data. Information collected and captured on a data gathering sheetincluded demographic data, information relating to the injury, occurrence of medical complications and length ofhospital stay. Linear regression analysis was computed in SPSS to determine factors affecting the length of stay.The necessary ethical considerations were adhered to during the implementation of the study. Current employmentstatus and the occurrence of pressure sores were significantly associated with the length of hospital stay (p=0.021 andp=0.000 respectively. A strong relationship was noted between pressure sores and length of stay (R= 0.703. There is aneed for all members of the rehabilitation team to devise and implement effective measures to prevent the developmentof pressure sores, in patients with spinal cord injuries in the study setting.

  17. Evaluation of skeletal and dental age using third molar calcification, condylar height and length of the mandibular body.

    Science.gov (United States)

    Kedarisetty, Sunil Gupta; Rao, Guttikonda Venkateswara; Rayapudi, Naveen; Korlepara, Rajani

    2015-01-01

    To identify the most reliable method for age estimation among three variables, that is, condylar height, length of mandibular body and third molar calcification by Demirjian's method. Orthopantomograms and lateral cephalograms of 60 patients with equal gender ratio were included in the study, among each gender 15 subjects were below 18 years and 15 subjects were above 18 years. Lateral cephalograms were traced, height of condyle and mandibular body are measured manually on the tracing paper, OPG's were observed on radiographic illuminator and maturity score of third molar calcification was noted according to Demirjian's method. All the measurements were subjected to statistical analysis. The results obtained are of no significant difference between estimated age and actual age with all three parameters (P > 0.9780 condylar height, P > 0.9515 length of mandibular body, P > 0.8611 third molar calcification). Among these three, length of mandibular body shows least standard error test (i.e. 0.188). Although all three parameters can be used for age estimation, length of mandibular body is more reliable followed by height of condyle and third molar calcification.

  18. Flaws in Commercial Reading Materials.

    Science.gov (United States)

    Axelrod, Jerome

    Three flaws found in commercial reading materials, such as workbooks and kits, are discussed in this paper, and examples of the flaws are taken from specific materials. The first problem noted is that illustrations frequently provide the information that the learner is supposed to supply through phonetic or structural analysis; the illustrations…

  19. Notes on Computational Methodology and Tools of Thermoelectric Energy Systems

    DEFF Research Database (Denmark)

    Chen, Min; Bach, Inger Palsgaard; Rosendahl, Lasse

    2007-01-01

    The SPICE model allows the concurrent simulation of thermoelectric devices and application electric sub-models. It is an important step to implement the thermoelectric modeling at the system level. In this paper, temperature dependent material properties in the SPICE model, temperature and heat...... flow obtained by the code ANSYS Multiphysics and SPICE (Simulation Program with Integrated Circuit Emphasis), as well as some notes on the 3-D extension of the SPICE model are introduced....

  20. Materials specificity, quantum length scales, and stopping powers

    International Nuclear Information System (INIS)

    Trickey, S.B.; Wu, Jin Z.; Sabin, John R.

    1994-01-01

    Standard arguments, based primarily on behavior at high projectile energies and classical notions of thickness as a continuous parameter, assert that stopping powers are only modestly affected by target chemistry and aggregation and by sample thickness if the thickness is ''sufficiently small'' (and channeling is avoided). Sufficient thinness usually is defined in terms of freedom from multiple scattering and from projectile charge-state changes. The growing technological importance of extremely thin material layers (e.g. microelectronics) has motivated re-examination of both the thickness and aggregation-state assertions. We give arguments to show that both are inadequate and reappraise recent computations in confirmation. A particular focus is the proper definition of thickness for an ultrathin film of ν atomic planes (ν=1, 2, 3,.s). ((orig.))

  1. Teaching the pharyngeal flap and sphincter pharyngoplasty: The sticky note method.

    Science.gov (United States)

    Lee, Jake J; Jabbour, Noel

    2015-11-01

    To demonstrate a cost-effective, quick, and easily reproducible three-dimensional sticky note model to enhance the understanding and conceptualization of the geometry and steps of the pharyngeal flap and sphincter pharyngoplasty. The method involves making specified incisions and rearrangements of readily available components, including disposable clear plastic cups, yellow and pink sticky notes, and white paper. Once assembly is complete, further incisions and remodeling are performed to simulate a pharyngeal flap or sphincter pharyngoplasty. The cost of the materials to make one model was $0.94. Average construction time was less than 10 min. This three-dimensional model is an efficient, interactive, and simple visual aid to teach surgical trainees the geometry and steps of the pharyngeal flap and sphincter pharyngoplasty. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  2. Project Notes

    Science.gov (United States)

    School Science Review, 1978

    1978-01-01

    Presents sixteen project notes developed by pupils of Chipping Norton School and Bristol Grammar School, in the United Kingdom. These Projects include eight biology A-level projects and eight Chemistry A-level projects. (HM)

  3. Do Branch Lengths Help to Locate a Tree in a Phylogenetic Network?

    Science.gov (United States)

    Gambette, Philippe; van Iersel, Leo; Kelk, Steven; Pardi, Fabio; Scornavacca, Celine

    2016-09-01

    Phylogenetic networks are increasingly used in evolutionary biology to represent the history of species that have undergone reticulate events such as horizontal gene transfer, hybrid speciation and recombination. One of the most fundamental questions that arise in this context is whether the evolution of a gene with one copy in all species can be explained by a given network. In mathematical terms, this is often translated in the following way: is a given phylogenetic tree contained in a given phylogenetic network? Recently this tree containment problem has been widely investigated from a computational perspective, but most studies have only focused on the topology of the phylogenies, ignoring a piece of information that, in the case of phylogenetic trees, is routinely inferred by evolutionary analyses: branch lengths. These measure the amount of change (e.g., nucleotide substitutions) that has occurred along each branch of the phylogeny. Here, we study a number of versions of the tree containment problem that explicitly account for branch lengths. We show that, although length information has the potential to locate more precisely a tree within a network, the problem is computationally hard in its most general form. On a positive note, for a number of special cases of biological relevance, we provide algorithms that solve this problem efficiently. This includes the case of networks of limited complexity, for which it is possible to recover, among the trees contained by the network with the same topology as the input tree, the closest one in terms of branch lengths.

  4. Is there still an unknown Freud? A note on the publications of Freud's texts and on unpublished documents.

    Science.gov (United States)

    Falzeder, Ernst

    2007-01-01

    This article presents an overview of the existing editions of what Freud wrote (works, letters, manuscripts and drafts, diaries and calendar notes, dedications and margin notes in books, case notes, and patient calendars) and what he is recorded as having said (minutes of meetings, interviews, memoirs of and interviews with patients, family members, and followers, and other quotes). There follows a short overview of biographies of Freud and other documentation on his life. It is concluded that a wealth of material is now available to Freud scholars, although more often than not this information is used in a biased and partisan way.

  5. Characteristics of suicide notes of children and young adolescents: an examination of the notes from suicide victims 15 years and younger.

    Science.gov (United States)

    Freuchen, Anne; Grøholt, Berit

    2015-04-01

    By analysing the suicide notes from suicide victims 15 years and younger, we attempt to gain insight into the process leading to youth suicide and explore the characteristics of the note writers. During a psychological autopsy on 42 youths, we were entrusted with 23 suicide notes in which we explored the themes and compared the note writers to the non-note writers. The key messages were as follows: explain the reason for suicide, declare love and give instructions. The note writers had showed suicidal behaviour more frequently than non-note writers. In the notes from youth suicide victims they present themselves as fully responsible and without confusion or overwhelming despair. The notes are likely equally informative as the notes of older victims. © The Author(s) 2013.

  6. Note-Making in Social Studies.

    Science.gov (United States)

    Fowler, Robert W.

    1985-01-01

    Note-making is one excellent method for helping students retain important points made by the teacher. Techniques that elementary and secondary social studies teacher can use to teach note-making skills are described. (RM)

  7. Extended-length fiber optic carbon dioxide monitoring

    Science.gov (United States)

    Delgado-Alonso, Jesus; Lieberman, Robert A.

    2013-05-01

    This paper discusses the design and performance of fiber optic distributed intrinsic sensors for dissolved carbon dioxide, based on the use optical fibers fabricated so that their entire lengths are chemically sensitive. These fibers use a polymer-clad, silica-core structure where the cladding undergoes a large, reversible, change in optical absorbance in the presence of CO2. The local "cladding loss" induced by this change is thus a direct indication of the carbon dioxide concentration in any section of the fiber. To create these fibers, have developed a carbon dioxide-permeable polymer material that adheres well to glass, is physically robust, has a refractive index lower than fused silica, and acts as excellent hosts for a unique colorimetric indicator system that respond to CO2. We have used this proprietary material to produce carbon-dioxide sensitive fibers up to 50 meters long, using commercial optical fiber fabrication techniques. The sensors have shown a measurement range of dissolved CO2 of 0 to 1,450 mg/l (0 to 100% CO2 saturation), limit of detection of 0.3 mg/l and precision of 1.0 mg/l in the 0 to 50 mg/l dissolved CO2 range, when a 5 meter-long sensor fiber segment is used. Maximum fiber length, minimum detectable concentration, and spatial resolution can be adjusted by adjusting indicator concentration and fiber design.

  8. DigiMemo: Facilitating the Note Taking Process

    Science.gov (United States)

    Kurt, Serhat

    2009-01-01

    Everyone takes notes daily for various reasons. Note taking is very popular in school settings and generally recognized as an effective learning strategy. Further, note taking is a complex process because it requires understanding, selection of information and writing. Some new technological tools may facilitate the note taking process. Among such…

  9. From LZ77 to the run-length encoded burrows-wheeler transform, and back

    DEFF Research Database (Denmark)

    Policriti, Alberto; Prezza, Nicola

    2017-01-01

    The Lempel-Ziv factorization (LZ77) and the Run-Length encoded Burrows-Wheeler Transform (RLBWT) are two important tools in text compression and indexing, being their sizes z and r closely related to the amount of text self-repetitiveness. In this paper we consider the problem of converting the t......(r + z) words of working space. Note that r and z can be constant if the text is highly repetitive, and our algorithms can operate with (up to) exponentially less space than naive solutions based on full decompression.......The Lempel-Ziv factorization (LZ77) and the Run-Length encoded Burrows-Wheeler Transform (RLBWT) are two important tools in text compression and indexing, being their sizes z and r closely related to the amount of text self-repetitiveness. In this paper we consider the problem of converting the two...... representations into each other within a working space proportional to the input and the output. Let n be the text length. We show that RLBWT can be converted to LZ77 in O(n log r) time and O(r) words of working space. Conversely, we provide an algorithm to convert LZ77 to RLBWT in O(n(log r + log z)) time and O...

  10. RESEARCH NOTE

    Indian Academy of Sciences (India)

    Navya

    RESEARCH NOTE. CDKN2A and MC1R ... Department of Pharmacy and Department of Nursing, School of Health Sciences, Frederick. University, Nicosia ..... Appears with highest frequency in African, Asian-Indian, and Papua. New Guinean ...

  11. Editorial note

    Directory of Open Access Journals (Sweden)

    Tore Ahlbäck

    2009-01-01

    Full Text Available Editorial note of the Scripta Instituti Donneriani Aboensis, vol. 21, Postmodern Spirituality, based on papers read at the symposium on Postmodern Spirituality held at Åbo, Finland, on 11–13 June 2008.

  12. Material reliability of Ni alloy electrodeposition for steam generator tube repair

    International Nuclear Information System (INIS)

    Kim, Dong Jin; Kim, Myong Jin; Kim, Joung Soo; Kim, Hong Pyo

    2007-01-01

    Due to the occasional occurrences of Stress Corrosion Cracking (SCC) in steam generator tubing (Alloy 600), degraded tubes are removed from service by plugging or are repaired for re-use. Since electrodeposition inside a tube dose not entail parent tube deformation, residual stress in the tube can be minimized. In this work, tube restoration via electrodeposition inside a steam generator tubing was performed after developing the following: an anode probe to be installed inside a tube, a degreasing condition to remove dirt and grease, an activation condition for surface oxide elimination, a tightly adhered strike layer forming condition between the electroforming layer and the Alloy 600 tube, and the condition for an electroforming layer. The reliability of the electrodeposited material, with a variation of material properties, was evaluated as a function of the electrodeposit position in the vertical direction of a tube using the developed anode. It has been noted that the variation of the material properties along the electrodeposit length was acceptable in a process margin. To improve the reliability of a material property, the causes of the variation occurrence were presumed, and an attempt to minimize the variation has been made. A Ni alloy electrodeposition process is suggested as a Primary Water Stress Corrosion Cracking (PWSCC) mitigation method for various components, including steam generator tubes. The Ni alloy electrodeposit formed inside a tube by using the installed assembly shows proper material properties as well as an excellent SCC resistance

  13. Reading and Note Taking in Monological and Dialogical Classes in the Social Sciences

    Science.gov (United States)

    Cartolari, Manuela; Carlino, Paula; Colombo, Laura M.

    2013-01-01

    This qualitative study explores the uses of reading and note-taking in two pre-service teacher training Social Sciences courses. Data analysis of in-depth interviews with professors and students, class observations and course materials suggested two polar teaching styles according to how bibliography was included in the course and the presence or…

  14. The Impact of Using Note Taking's Techniques on the Students' Learning

    Directory of Open Access Journals (Sweden)

    Asrar Jabir Edan

    2017-03-01

    Full Text Available It is often said that the worst pen is better than the best memory and regardless of how good the students' memory might be, they need to take notes during the lesson or lecture because it is impossible to remember all the details later on. This is so easy to use technique which requires a brief record of important information can help students not only recall what has been said in the class, but also to achieve their learning goals and provide a useful summary of the material to be revised especially before the test. Unfortunately, it is noticed that most of the students, especially at the secondary stage, neglect this important skill. Most of them don’t often write notes unless they are told to do so by the teacher or depend only on the textbooks forgetting that not all the material mentioned during the lesson found in them as some are explanations to the complex and abstract ones and others are related to the teacher's experience in the subject matter. In fact, note taking skill is part of the learning process and to be useful, students need to learn how to do it effectively and what to record because not all what is said is important. This requires acquiring more than one skill on the part of the learners and more effort on the part of the teacher to teach them how to do it properly. For the above reasons, more light will be shed in this research on this topic followed by an experiment and a test to evaluate its effectiveness in learning

  15. Developing Higher-Order Materials Knowledge Systems

    Science.gov (United States)

    Fast, Anthony Nathan

    2011-12-01

    Advances in computational materials science and novel characterization techniques have allowed scientists to probe deeply into a diverse range of materials phenomena. These activities are producing enormous amounts of information regarding the roles of various hierarchical material features in the overall performance characteristics displayed by the material. Connecting the hierarchical information over disparate domains is at the crux of multiscale modeling. The inherent challenge of performing multiscale simulations is developing scale bridging relationships to couple material information between well separated length scales. Much progress has been made in the development of homogenization relationships which replace heterogeneous material features with effective homogenous descriptions. These relationships facilitate the flow of information from lower length scales to higher length scales. Meanwhile, most localization relationships that link the information from a from a higher length scale to a lower length scale are plagued by computationally intensive techniques which are not readily integrated into multiscale simulations. The challenge of executing fully coupled multiscale simulations is augmented by the need to incorporate the evolution of the material structure that may occur under conditions such as material processing. To address these challenges with multiscale simulation, a novel framework called the Materials Knowledge System (MKS) has been developed. This methodology efficiently extracts, stores, and recalls microstructure-property-processing localization relationships. This approach is built on the statistical continuum theories developed by Kroner that express the localization of the response field at the microscale using a series of highly complex convolution integrals, which have historically been evaluated analytically. The MKS approach dramatically improves the accuracy of these expressions by calibrating the convolution kernels in these

  16. Communication received from the permanent mission of Austria regarding the provision of certain additional information on production, inventories and international transfers of nuclear material and on exports of certain relevant equipment and non-nuclear material

    International Nuclear Information System (INIS)

    1996-01-01

    The Director General received a note verbale of 13 June 1996 from Permanent Mission of Austria regarding the provision of certain additional information on production, inventories and international transfers of nuclear material and on exports of certain relevant equipment and non-nuclear material. In the light of the request expressed at the end of the note verbale, the text of the note verbale is being circulated

  17. Communication received from the permanent mission of Finland regarding the provision of certain additional information on production, inventories and international transfers of nuclear material and on exports of certain relevant equipment and non-nuclear material

    International Nuclear Information System (INIS)

    1996-01-01

    The Director General received a note verbale of 8 February 1996 from Permanent Mission of Finland regarding the provision of certain additional information on production, inventories and international transfers of nuclear material and on exports of certain relevant equipment and non-nuclear material. In the light of the request expressed at the and of the note verbale, the text of the note verbale is being circulated

  18. The importance of chain length for the polyphosphate enhancement of acidic potassium permanganate chemiluminescence.

    Science.gov (United States)

    Holland, Brendan J; Adcock, Jacqui L; Nesterenko, Pavel N; Peristyy, Anton; Stevenson, Paul G; Barnett, Neil W; Conlan, Xavier A; Francis, Paul S

    2014-09-09

    Sodium polyphosphate is commonly used to enhance chemiluminescence reactions with acidic potassium permanganate through a dual enhancement mechanism, but commercially available polyphosphates vary greatly in composition. We have examined the influence of polyphosphate composition and concentration on both the dual enhancement mechanism of chemiluminescence intensity and the stability of the reagent under analytically useful conditions. The average chain length (n) provides a convenient characterisation, but materials with similar values can exhibit markedly different distributions of phosphate oligomers. There is a minimum polyphosphate chain length (∼6) required for a large enhancement of the emission intensity, but no further advantage was obtained using polyphosphate materials with much longer average chain lengths. Providing there is a sufficient average chain length, the optimum concentration of polyphosphate is dependent on the analyte and in some cases, may be lower than the quantities previously used in routine detection. However, the concentration of polyphosphate should not be lowered in permanganate reagents that have been partially reduced to form high concentrations of the key manganese(III) co-reactant, as this intermediate needs to be stabilised to prevent formation of insoluble manganese(IV). Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Lecture notes on wavelet transforms

    CERN Document Server

    Debnath, Lokenath

    2017-01-01

    This book provides a systematic exposition of the basic ideas and results of wavelet analysis suitable for mathematicians, scientists, and engineers alike. The primary goal of this text is to show how different types of wavelets can be constructed, illustrate why they are such powerful tools in mathematical analysis, and demonstrate their use in applications. It also develops the required analytical knowledge and skills on the part of the reader, rather than focus on the importance of more abstract formulation with full mathematical rigor.  These notes differs from many textbooks with similar titles in that a major emphasis is placed on the thorough development of the underlying theory before introducing applications and modern topics such as fractional Fourier transforms, windowed canonical transforms, fractional wavelet transforms, fast wavelet transforms, spline wavelets, Daubechies wavelets, harmonic wavelets and non-uniform wavelets. The selection, arrangement, and presentation of the material in these ...

  20. Length-weight and length-length relationships of common carp (Cyprinus carpio L.) in the middle and southern Iraq provinces

    Science.gov (United States)

    Al-jebory, Taymaa A.; Das, Simon K.; Usup, Gires; Bakar, Y.; Al-saadi, Ali H.

    2018-04-01

    In this study, length-weight and length-length relationships of common carp (Cyprinus carpio L.) in the middle and southern Iraq provinces were determined. Fish specimens were procured from seven provinces from July to December, 2015. A negative and positive allometric growth pattern was obtained, where the total length (TL) ranged from 25.60 cm to 33.53 cm, and body weight (BW) ranged from 700 g to 1423 g. Meanwhile, the lowest of 1.03 and highest of 3.54 in "b" value was recorded in group F and group C, respectively. Therefore, Fulton condition factor (K) range from 2.57 to 4.94. While, relative condition factor (Kn) was in the ranged of 0.95 to 1.01. A linear relationship between total length (TL) and standard length (SL) among the provinces for fish groups was obtained. The variances in "b" value ranged from 0.10 to 0.93 with correlation coefficient (r2) of 0.02 to 0.97. This research could be used as a guide to study the ecology and biology of common Carp (Cyprinus carpio L.) in the middle and southern Iraq provinces.

  1. Prospective randomized clinical trial comparing laparoscopic cholecystectomy and hybrid natural orifice transluminal endoscopic surgery (NOTES) (NCT00835250).

    Science.gov (United States)

    Noguera, José F; Cuadrado, Angel; Dolz, Carlos; Olea, José M; García, Juan C

    2012-12-01

    Natural orifice transluminal endoscopic surgery (NOTES) is a technique still in experimental development whose safety and effectiveness call for assessment through clinical trials. In this paper we present a three-arm, noninferiority, prospective randomized clinical trial of 1 year duration comparing the vaginal and transumbilical approaches for transluminal endoscopic surgery with the conventional laparoscopic approach for elective cholecystectomy. Sixty female patients between the ages of 18 and 65 years who were eligible for elective cholecystectomy were randomized in a ratio of 1:1:1 to receive hybrid transvaginal NOTES (TV group), hybrid transumbilical NOTES (TU group) or conventional laparoscopy (CL group). The main study variable was parietal complications (wound infection, bleeding, and eventration). The analysis was by intention to treat, and losses were not replaced. Cholecystectomy was successfully performed on 94% of the patients. One patient in the TU group was reconverted to CL owing to difficulty in maneuvering the endoscope. After a minimum follow-up period of 1 year, no differences were noted in the rate of parietal complications. Postoperative pain, length of hospital stay, and time off from work were similar in the three groups. No patient developed dyspareunia. Surgical time was longer among cases in which a flexible endoscope was used (CL, 47.04 min; TV, 64.85 min; TU, 59.80 min). NOTES approaches using the flexible endoscope are not inferior in safety or effectiveness to conventional laparoscopy. The transumbilical approach with flexible endoscope is as effective and safe as the transvaginal approach and is a promising, single-incision approach.

  2. PET-CT offers accurate assessment of tumour length in oesophageal malignancy

    International Nuclear Information System (INIS)

    Rollins, K.E.; Lucas, E.; Tewari, N.; James, E.; Hughes, S.; Catton, J.A.

    2015-01-01

    Highlights: • We examine the accuracy of staging modalities in estimating tumour length of oesophageal malignancy. • PET CT correlates most strongly with histopathological length of resected specimen. • Better measure than EUS with OGD correlating poorly. • Potential impact in radiotherapy and surgical resection planning. - Abstract: Introduction: Radiotherapy is increasingly used for both curative and palliative treatment of oesophageal malignancy. Accurate treatment depends on determining tumour location and length. This study assessed the value of PET-CT versus other staging modalities in determining tumour length. Materials and methods: Oesophageal cancer patients who underwent staging with PET/CT and endoscopic ultrasound (EUS) in addition to their diagnostic upper GI endoscopy and subsequent surgical resection were assessed. PET/CT length was obtained retrospectively by using Hermes Hybrid Viewer™ with a 1–5 Standardised Uptake Value grey scale. An SUV of 5 was used as the cut off for determining length. Direct measurement by EUS and OGD were determined. Results: 53 patients underwent PET-CT, EUS, OGD and surgical resection for oesophageal cancer. Overall the correlation between PET-CT and histopathological length was strongest (Pearson r = 0.5977, 95% CI 0.390–0.747) versus EUS (Pearson R = 0.5365, 95% CI 0.311–0.705) and OGD (Pearson r = 0.1574, 95% CI −0.118 to 0.410). After excluding tumours with a significant chemotherapy response, PET-CT length correlated significantly with histopathological length (R = 0.5651, p = 0.0005). In comparison, the correlation between histological length and EUS (R = 0.4637, p = 0.0057) measurement was less significant and this did not correlate with OGD (R = −0.1084, p = 0.5417). Conclusion: Tumour length estimated by PET-CT correlated most strongly with histopathological length of oesophageal malignancy and is the most accurate determinant of tumour length of all the staging modalities. This suggests a

  3. PET-CT offers accurate assessment of tumour length in oesophageal malignancy

    Energy Technology Data Exchange (ETDEWEB)

    Rollins, K.E., E-mail: james.catton@nuh.nhs.uk [Department of Oesophago-Gastric Surgery, Nottingham University Hospitals, Hucknall Road, Nottingham (United Kingdom); Lucas, E. [University of Nottingham, Derby Road, Nottingham (United Kingdom); Tewari, N. [Department of Oesophago-Gastric Surgery, Nottingham University Hospitals, Hucknall Road, Nottingham (United Kingdom); James, E. [Department of Oncology, Nottingham University Hospitals, Hucknall Road, Nottingham (United Kingdom); Hughes, S. [Department of Radiology, Nottingham University Hospitals, Hucknall Road, Nottingham (United Kingdom); Catton, J.A. [Department of Oesophago-Gastric Surgery, Nottingham University Hospitals, Hucknall Road, Nottingham (United Kingdom)

    2015-02-15

    Highlights: • We examine the accuracy of staging modalities in estimating tumour length of oesophageal malignancy. • PET CT correlates most strongly with histopathological length of resected specimen. • Better measure than EUS with OGD correlating poorly. • Potential impact in radiotherapy and surgical resection planning. - Abstract: Introduction: Radiotherapy is increasingly used for both curative and palliative treatment of oesophageal malignancy. Accurate treatment depends on determining tumour location and length. This study assessed the value of PET-CT versus other staging modalities in determining tumour length. Materials and methods: Oesophageal cancer patients who underwent staging with PET/CT and endoscopic ultrasound (EUS) in addition to their diagnostic upper GI endoscopy and subsequent surgical resection were assessed. PET/CT length was obtained retrospectively by using Hermes Hybrid Viewer™ with a 1–5 Standardised Uptake Value grey scale. An SUV of 5 was used as the cut off for determining length. Direct measurement by EUS and OGD were determined. Results: 53 patients underwent PET-CT, EUS, OGD and surgical resection for oesophageal cancer. Overall the correlation between PET-CT and histopathological length was strongest (Pearson r = 0.5977, 95% CI 0.390–0.747) versus EUS (Pearson R = 0.5365, 95% CI 0.311–0.705) and OGD (Pearson r = 0.1574, 95% CI −0.118 to 0.410). After excluding tumours with a significant chemotherapy response, PET-CT length correlated significantly with histopathological length (R = 0.5651, p = 0.0005). In comparison, the correlation between histological length and EUS (R = 0.4637, p = 0.0057) measurement was less significant and this did not correlate with OGD (R = −0.1084, p = 0.5417). Conclusion: Tumour length estimated by PET-CT correlated most strongly with histopathological length of oesophageal malignancy and is the most accurate determinant of tumour length of all the staging modalities. This suggests a

  4. Children's note taking as a mnemonic tool.

    Science.gov (United States)

    Eskritt, Michelle; McLeod, Kellie

    2008-09-01

    When given the opportunity to take notes in memory tasks, children sometimes make notes that are not useful. The current study examined the role that task constraints might play in the production of nonmnemonic notes. In Experiment 1, children played one easy and one difficult memory game twice, once with the opportunity to make notes and once without that opportunity. More children produced functional notations for the easier task than for the more difficult task, and their notations were beneficial to memory performance. Experiment 2 found that the majority of children who at first made nonmnemonic notations were able to produce functional notations with minimal training, and there was no significant difference in notation quality or memory performance between spontaneous and trained note takers. Experiment 3 revealed that the majority of children could transfer their training to a novel task. The results suggest that children's production of nonmnemonic notes may be due in part to a lack of knowledge regarding what task information is important to represent or how to represent it in their notes rather than to an inability to make functional notes in general.

  5. Ultrashort Channel Length Black Phosphorus Field-Effect Transistors.

    Science.gov (United States)

    Miao, Jinshui; Zhang, Suoming; Cai, Le; Scherr, Martin; Wang, Chuan

    2015-09-22

    This paper reports high-performance top-gated black phosphorus (BP) field-effect transistors with channel lengths down to 20 nm fabricated using a facile angle evaporation process. By controlling the evaporation angle, the channel length of the transistors can be reproducibly controlled to be anywhere between 20 and 70 nm. The as-fabricated 20 nm top-gated BP transistors exhibit respectable on-state current (174 μA/μm) and transconductance (70 μS/μm) at a VDS of 0.1 V. Due to the use of two-dimensional BP as the channel material, the transistors exhibit relatively small short channel effects, preserving a decent on-off current ratio of 10(2) even at an extremely small channel length of 20 nm. Additionally, unlike the unencapsulated BP devices, which are known to be chemically unstable in ambient conditions, the top-gated BP transistors passivated by the Al2O3 gate dielectric layer remain stable without noticeable degradation in device performance after being stored in ambient conditions for more than 1 week. This work demonstrates the great promise of atomically thin BP for applications in ultimately scaled transistors.

  6. [Nutritional status recording in hospitalized patient notes].

    Science.gov (United States)

    Matos, L; Teixeira, M A; Henriques, A; Tavares, M M; Alvares, L; Antunes, A; Amaral, Teresa F

    2007-01-01

    The prevalence of disease-related malnutrition (DRM) is described to be of 30-60% on admission to hospital, and of 10% in the community. It has been associated with worse clinical outcomes, namely higher morbidity and mortality as well as higher frequency of health care and its associated costs. The lack of screening and monitoring of nutritional status have been said to be risk factors for the increased prevalence of DRM during hospital stay. The aims of this study were to evaluate the importance given by health care professionals to certain aspects related with nutritional status (weight, food intake) of hospital patients and to see if there were any differences between the under and non undernourished ones. A systematic sample of patients from six hospitals was collected. Pregnancy, paediatric age and critical illness were exclusion criteria as well as incapacity to fulfil nutritional risk screening protocol and length-of-stay less than 24h. Socio-demographic, anthropometric data and clinical notes (e.g. weight, food/nutrient intake) from medical records were collected and Nutritional Risk Screening 2002 protocol was applied. A total of 1152 patients were included in this study. The prevalence of nutritional risk varied between 28.5% and 47.3% while undernutrition classified by anthropometrical parameters was considerably lower (6.3% to 14.9%). Two thirds of the patients had their food intake monitored and registered in medical records but only one third were weighted. Undernourished patients had their food intake more frequently monitored but their weight was less frequently measured, than the well-nourished ones. DRM prevalence amongst hospital patients on admission is significantly high. Clinical notes regarding nutritional status is rather infrequent on medical records. This study showed that urges the need to empower health care providers of the importance of the screening and monitoring of weight and food intake, on admission and during hospital stay.

  7. 19 CFR 10.536 - Value of materials.

    Science.gov (United States)

    2010-04-01

    ...) Accounting method. Any cost or value referenced in General Note 25, HTSUS and this subpart, must be recorded... 19 Customs Duties 1 2010-04-01 2010-04-01 false Value of materials. 10.536 Section 10.536 Customs... Rules of Origin § 10.536 Value of materials. (a) Calculating the value of materials. Except as provided...

  8. Concordance and interchangeability of biometric measurements of ocular axial length in patients awaiting cataract surgery.

    Science.gov (United States)

    Martín-Serrano, María José; Roman-Ortiz, Carmen; Villa-Sáez, M Luz; Labrador-Castellanos, M Purificación; Blanco-Carrasco, Rosario; Lozano-Ballesteros, Felicidad; Pedraza-Martín, Carmen; José-Herrero, M Teresa San; López-Ropero, Ana M; Tenías Burillo, José María

    2014-01-01

    To estimate in patients awaiting cataract surgery the concordance and interchangeability of axial eye length measurements performed with the aid of various biometric methods (optical or ultrasonic) by different operators (nurses) at different times during the period prior to surgery. We selected 182 consecutive eyes from 91 patients.Ocular axial length was measured with the aid of 2 methods (IOLMaster® and Ocuscan®) by 9 randomly allocated technicians at 2 different times during the waiting period. The concordance between measurements was evaluated by means of the intraclass correlation coefficient (ICC); the interchangeability of the results was assessed with Bland Altman plots and Passing and Bablok regression. The measurements were consistent between biometric methods (ICC 0.975, 95% confidence interval [CI] 0.968 to 0.980) and measurement dates (ICC 0.996, 95% CI 0.995 to 0.997). Interobserver agreement was more heterogeneous (ICC range 0.844 to 0.998). No systematic errors were observed among the various biometric methods and measurement dates. Because measurement of axial length in phakic patients may be technician-dependent, the technician's experience should be noted in the protocols of ophthalmology services.

  9. Notes on two species of Processa (Decapoda: Processidae from the Mexican Pacific

    Directory of Open Access Journals (Sweden)

    Manuel Ayón-Parente

    Full Text Available Material belonging to the genus Processa, held in the Regional Marine Invertebrates Collection in Mazatlán, Mexico, is revised including specimens of the widely distributed P. peruviana, and the scarcely collected P. hawaiensis. For comparative purposes with the specimens from Hawaii and other localities, a detailed description of a male of P. hawaiensis collected in continental Mexico is provided, including illustrations of all appendages. Small differences are noted with previous description and partial redescriptions of this species, including proportion between propodus and dactylus of the fourth pereopod, and between merus and carpus of the right cheliped. In addition, the shape and setation of the first pair of pleopods in the Mexican material differs from the description of P. hawaiensis based on African material.

  10. Analytical dynamics course notes

    CERN Document Server

    Lindenbaum, Samuel D

    1994-01-01

    This book comprises a set of lecture notes on rational mechanics, for part of the graduate physics curriculum, delivered by the late Prof. Shirley L. Quimby during his tenure at Columbia University, New York. The notes contain proofs of basic theorems, derivations of formulae and amplification of observations, as well as the presentation and solution of illustrative problems. Collateral readings from more than 50 source references are indicated at appropriate places in the text.

  11. Lecture notes for introduction to nuclear engineering 101

    International Nuclear Information System (INIS)

    Fullwood, R.; Cadwell, J.

    1992-03-01

    The lecture notes for introductory nuclear engineering are provided for Department of Energy personnel that are recent graduates, transfers from non-nuclear industries, and people with minimum engineering training. The material assumes a knowledge of algebra and elementary calculus. These notes support and supplement a three-hour lecture. The reader is led into the subject from the familiar macroscopic world to the microscopic world of atoms and the parts of atoms called elementary particles. Only a passing reference is made to the very extensive world of quarks and tansitory particles to concentrate on those associated with radioactivity and fission. The Einsteinian truth of mass-energy equivalence provides an understanding of the forces binding a nucleus with a resulting mass defect that results in fusion at one end of the mass spectrum and fission at the other. Exercises are provided in calculating the energy released in isotopic transformation, reading and understanding the chart of the nuclides. The periodic table is reviewed to appreciate that the noble elements are produced by quantum mechanical shell closings. Radioactive decay is calculated as well as nuclear penetration and shielding. The geometric attenuation of radiation is studied for personal protection; the use of shielding materials for radiation protection is presented along with the buildup factor that renders the shielding less effective than might be supposed. The process of fission is presented along with the fission products and energies produced by fission. The requirements for producing a sustained chain reactor are discussed. The lecture ends with discussions of how radiation and dose is measured and how dose is converted to measures of the damage of radiation to our bodies

  12. Telomere Length and Mortality

    DEFF Research Database (Denmark)

    Kimura, Masayuki; Hjelmborg, Jacob V B; Gardner, Jeffrey P

    2008-01-01

    Leukocyte telomere length, representing the mean length of all telomeres in leukocytes, is ostensibly a bioindicator of human aging. The authors hypothesized that shorter telomeres might forecast imminent mortality in elderly people better than leukocyte telomere length. They performed mortality...

  13. Mechanics of soft materials

    CERN Document Server

    Volokh, Konstantin

    2016-01-01

    This book provides a concise introduction to soft matter modelling. It offers an up-to-date review of continuum mechanical description of soft and biological materials from the basics to the latest scientific materials. It includes multi-physics descriptions, such as chemo-, thermo-, electro- mechanical coupling. It derives from a graduate course at Technion that has been established in recent years. It presents original explanations for some standard materials and features elaborated examples on all topics throughout the text. PowerPoint lecture notes can be provided to instructors. .

  14. Open notes: doctors and patients signing on.

    Science.gov (United States)

    Delbanco, Tom; Walker, Jan; Darer, Jonathan D; Elmore, Joann G; Feldman, Henry J; Leveille, Suzanne G; Ralston, James D; Ross, Stephen E; Vodicka, Elisabeth; Weber, Valerie D

    2010-07-20

    Few patients read their doctors' notes, despite having the legal right to do so. As information technology makes medical records more accessible and society calls for greater transparency, patients' interest in reading their doctors' notes may increase. Inviting patients to review these notes could improve understanding of their health, foster productive communication, stimulate shared decision making, and ultimately lead to better outcomes. Yet, easy access to doctors' notes could have negative consequences, such as confusing or worrying patients and complicating rather than improving patient-doctor communication. To gain evidence about the feasibility, benefits, and harms of providing patients ready access to electronic doctors' notes, a team of physicians and nurses have embarked on a demonstration and evaluation of a project called OpenNotes. The authors describe the intervention and share what they learned from conversations with doctors and patients during the planning stages. The team anticipates that "open notes" will spread and suggests that over time, if drafted collaboratively and signed by both doctors and patients, they might evolve to become contracts for care.

  15. Correlation of normal-range FMR1 repeat length or genotypes and reproductive parameters.

    Science.gov (United States)

    Maslow, Bat-Sheva L; Davis, Stephanie; Engmann, Lawrence; Nulsen, John C; Benadiva, Claudio A

    2016-09-01

    This study aims to ascertain whether the length of normal-ranged CGG repeats on the FMR1 gene correlates with abnormal reproductive parameters. We performed a retrospective, cross-sectional study of all FMR1 carrier screening performed as part of routine care at a large university-based fertility center from January 2011 to March 2014. Correlations were performed between normal-range FMR1 length and baseline serum anti-Müllerian hormone (AMH), cycle day 3 follicle stimulating hormone (FSH), ovarian volumes (OV), antral follicle counts (AFC), and incidence of diminished ovarian reserve (DOR), while controlling for the effect of age. Six hundred three FMR1 screening results were collected. One subject was found to be a pre-mutation carrier and was excluded from the study. Baseline serum AMH, cycle day 3 FSH, OV, and AFC data were collected for the 602 subjects with normal-ranged CGG repeats. No significant difference in median age was noted amongst any of the FMR1 repeat genotypes. No significant correlation or association was found between any allele length or genotype, with any of the reproductive parameters or with incidence of DOR at any age (p > 0.05). However, subjects who were less than 35 years old with low/low genotype were significantly more likely to have below average AMH levels compared to those with normal/normal genotype (RR 3.82; 95 % CI 1.38-10.56). This large study did not demonstrate any substantial association between normal-range FMR1 repeat lengths and reproductive parameters.

  16. The Anatomy of a Note.

    Science.gov (United States)

    Moore, Herb

    1986-01-01

    Suggests that students can learn the physics of a musical note by learning how to synthesize sounds on a computer. Discusses ADSR (attack, decay, sustain, and release of a note) and includes a program (with listing) which students can use to examine ADSR on a Commodore 64 microcomputer. (JN)

  17. Observation of long phase-coherence length in epitaxial La-doped CdO thin films

    Science.gov (United States)

    Yun, Yu; Ma, Yang; Tao, Songsheng; Xing, Wenyu; Chen, Yangyang; Su, Tang; Yuan, Wei; Wei, Jian; Lin, Xi; Niu, Qian; Xie, X. C.; Han, Wei

    2017-12-01

    The search for long electron phase-coherence length, which is the length that an electron can keep its quantum wavelike properties, has attracted considerable interest in the last several decades. Here, we report the long phase-coherence length of ˜3.7 μm in La-doped CdO thin films at 2 K. Systematical investigations of the La doping and the temperature dependences of the electron mobility and the electron phase-coherence length reveal contrasting scattering mechanisms for these two physical properties. Furthermore, these results show that the oxygen vacancies could be the dominant scatters in CdO thin films that break the electron phase coherence, which would shed light on further investigation of phase-coherence properties in oxide materials.

  18. A STUDY OF CORRELATION OF FOOT LENGTH AND GESTATIONAL MATURITY IN NEONATES

    Directory of Open Access Journals (Sweden)

    M. Bhuvaneswari

    2018-03-01

    Full Text Available BACKGROUND Gestational age estimation at birth can be done by clinical estimation through careful history of LMP, ultrasonic estimation of gestational age, date of first recorded foetal activity “quickening” first felt at approximately 16-18 weeks, Date of first recorded foetal heart sounds. MATERIALS AND METHODS A study sample of 800 live newborns were selected by simple random sampling technique born at GVR hospital and Government General Hospital, Kurnool from April 2015 to May 2016. Data was collected using standard proforma meeting the objectives of the study. a Gestational age assessment was done using modified Bellard’s score and b Foot length was measured using sliding calipers which is having an accuracy of a millimeter. Following instruments are used: 1 Sliding calipers for measuring foot length, 2 Flexible, non-stretchable measuring tape for head circumference, 3 Infantometer for measuring crown heel length, 4 Electronic weighing scale for measuring weight. RESULTS The foot length of preterm neonates ranged from 4.5-7.8 cm with the mean foot length of 6.1571 cm and 6.6964 cm for preterm SGA and AGA, respectively. The foot length of term neonates ranged from 5.4-8.7 cm with a mean foot length of 7.0471 cm, 7.5703 cm, 8.0391 cm for term SGA, AGA, LGA respectively. The foot length for post term neonates ranged from 6.7-8.8 cm, with a mean foot length of 7.5688 cm, 8.0170 cm and 8.2667 cm for post term SGA, AGA and LGA, respectively. This shows that foot length increases as the gestational age increases. CONCLUSION Foot length can be correlated significantly with the gestational age, birth weight, head circumference and crown heel length.

  19. A case of 45,X/47,XXX mosaic Turner syndrome with limb length discrepancy.

    Science.gov (United States)

    Hishimura-Yonemaru, Nozomi; Okuhara, Koji; Takahashi, Nobuhiro; Tonoki, Hidefumi; Iizuka, Susumu; Tajima, Toshihiro

    2017-01-01

    Patients with Turner syndrome (TS) frequently show short stature and skeletal deformities, such as kyphosis and scoliosis. However, to the best of our knowledge, limb length discrepancy (LLD) has not yet been reported in patients with TS. The case of a 12-yr-old girl with 45,X/47,XXX mosaic TS showing LLD is herein presented. She was on GH therapy for short stature and was noted to have scoliosis in the standing position at a regular examination; however, the scoliosis became less evident in the supine position, which is indicative of LLD. The length of the left leg was 5.0 cm shorter than that of the right leg when measured. She was referred to orthopedics and underwent right distal femoral and right proximal tibial staple epiphysiodesis to shorten the abnormally long limb at 10 yr 6 mo of age. One year after the operation, the LLD decreased from 5.0 to 1.5 cm. During this period, GH was continued. LLD is a rare complication in TS, but when patients with TS show scoliosis in the standing position, re-evaluation for scoliosis in the supine position should be performed and the lengths of both legs should be measured.

  20. Molecular gastronomy is a scientific discipline, and note by note cuisine is the next culinary trend

    Directory of Open Access Journals (Sweden)

    This Hervé

    2013-01-01

    Full Text Available Abstract For the past two decades, there has been much confusion about molecular gastronomy. This confusion has arisen because people ignore that the word gastronomy does not mean cuisine, it means knowledge about food. Similar to ‘molecular biology’, molecular gastronomy is a scientific discipline that looks for the mechanisms of phenomena occurring during dish preparation and consumption. As with any other scientific discipline, it can have many applications. One of the first was ‘molecular cuisine’ but since 1994, ‘note by note cuisine’ has also been promoted. The latter involves preparing dishes using pure compounds, or more practically mixture of compounds obtained by fractioning plant or animal tissues, instead of using these tissues themselves. Note by note cuisine raises issues in various fields: science, technology, nutrition, physiology, toxicology and politics.

  1. Gaz de France. Operation note; Gaz de France. Note d'operation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-07-01

    This note was published for the public at the occasion of the admission to Euronext's Eurolist of the existing shares that make the capital of Gaz de France company, the French gas utility. The note gives some informations about Gaz de France activity, and about its strategy of development in the European gas market. Then it describes the offer relative to the opening of Gaz de France capital. Some selected financial data and some precision about the risk factors and the management of the company complete the document. (J.S.)

  2. OpenLabNotes

    DEFF Research Database (Denmark)

    List, Markus; Franz, Michael; Tan, Qihua

    2015-01-01

    be advantageous if an ELN was Integrated with a laboratory information management system to allow for a comprehensive documentation of experimental work including the location of samples that were used in a particular experiment. Here, we present OpenLabNotes, which adds state-of-the-art ELN capabilities to Open......LabFramework, a powerful and flexible laboratory information management system. In contrast to comparable solutions, it allows to protect the intellectual property of its users by offering data protection with digital signatures. OpenLabNotes effectively Closes the gap between research documentation and sample management......, thus making Open-Lab Framework more attractive for laboratories that seek to increase productivity through electronic data management....

  3. Space and materiality in early childhood pedagogy – introductory notes

    OpenAIRE

    Løkken, Gunvor; Moser, Thomas

    2012-01-01

    This issue of Education Inquiry includes a thematic section with five articles about different aspects of the physical environment in Norwegian early childhood education institutions (kindergartens). The contributions represent five out of nine sub-projects in a research project entitled Kindergarten space – materiality, learning and meaning making – The importance of space for kindergarten’s pedagogical activities conducted at Vestfold University College (VUC) funded by the Norwegian Researc...

  4. Bank note recognition for the vision impaired.

    Science.gov (United States)

    Hinwood, A; Preston, P; Suaning, G J; Lovell, N H

    2006-06-01

    Blind Australians find great difficulty in recognising bank notes. Each note has the same feel, with no Braille markings, irregular edges or other tangible features. In Australia, there is only one device available that can assist blind people recognise their notes. Internationally, there are devices available; however they are expensive, complex and have not been developed to cater for Australian currency. This paper discusses a new device, the MoneyTalker that takes advantage of the largely different colours and patterns on each Australian bank note and recognises the notes electronically, using the reflection and transmission properties of light. Different coloured lights are transmitted through the inserted note and the corresponding sensors detect distinct ranges of values depending on the colour of the note. Various classification algorithms were studied and the final algorithm was chosen based on accuracy and speed of recognition. The MoneyTalker has shown an accuracy of more than 99%. A blind subject has tested the device and believes that it is usable, compact and affordable. Based on the devices that are available currently in Australia, the MoneyTalker is an effective alternative in terms of accuracy and usability.

  5. Note: Making tens of centimeter long uniform microfluidic channels using commercial glass pipette

    Science.gov (United States)

    Ou, Neil; Lee, Huang-Ming; Wu, Jong-Ching

    2018-03-01

    Producing microchannels with diameters between 10 and 20 μm and with lengths in the tens of centimeters is reported. The method can be modified to obtain diameters as narrow as 350 nm. Length-to-diameter aspect ratios that surpass 104 can be produced for a fraction of current production costs. The controllable channel is produced by applying a flame to the narrow end of a commercial pipette that is made from a soda-lime silicate. In combination with a pulling mechanism, applying heat to the composite material lengthens the pipette in a highly uniform way. Given that the materials and methods in this research are cost-effective when compared to femtosecond laser micromachining on 2D silicon-based surfaces, further research into producing microchannels from soda-lime silicates may revolutionize access to 3D controllable microchannels.

  6. Elasticity of short DNA molecules: theory and experiment for contour lengths of 0.6-7 microm.

    Science.gov (United States)

    Seol, Yeonee; Li, Jinyu; Nelson, Philip C; Perkins, Thomas T; Betterton, M D

    2007-12-15

    The wormlike chain (WLC) model currently provides the best description of double-stranded DNA elasticity for micron-sized molecules. This theory requires two intrinsic material parameters-the contour length L and the persistence length p. We measured and then analyzed the elasticity of double-stranded DNA as a function of L (632 nm-7.03 microm) using the classic solution to the WLC model. When the elasticity data were analyzed using this solution, the resulting fitted value for the persistence length p(wlc) depended on L; even for moderately long DNA molecules (L = 1300 nm), this apparent persistence length was 10% smaller than its limiting value for long DNA. Because p is a material parameter, and cannot depend on length, we sought a new solution to the WLC model, which we call the "finite wormlike chain (FWLC)," to account for effects not considered in the classic solution. Specifically we accounted for the finite chain length, the chain-end boundary conditions, and the bead rotational fluctuations inherent in optical trapping assays where beads are used to apply the force. After incorporating these corrections, we used our FWLC solution to generate force-extension curves, and then fit those curves with the classic WLC solution, as done in the standard experimental analysis. These results qualitatively reproduced the apparent dependence of p(wlc) on L seen in experimental data when analyzed with the classic WLC solution. Directly fitting experimental data to the FWLC solution reduces the apparent dependence of p(fwlc) on L by a factor of 3. Thus, the FWLC solution provides a significantly improved theoretical framework in which to analyze single-molecule experiments over a broad range of experimentally accessible DNA lengths, including both short (a few hundred nanometers in contour length) and very long (microns in contour length) molecules.

  7. Does length or neighborhood size cause the word length effect?

    Science.gov (United States)

    Jalbert, Annie; Neath, Ian; Surprenant, Aimée M

    2011-10-01

    Jalbert, Neath, Bireta, and Surprenant (2011) suggested that past demonstrations of the word length effect, the finding that words with fewer syllables are recalled better than words with more syllables, included a confound: The short words had more orthographic neighbors than the long words. The experiments reported here test two predictions that would follow if neighborhood size is a more important factor than word length. In Experiment 1, we found that concurrent articulation removed the effect of neighborhood size, just as it removes the effect of word length. Experiment 2 demonstrated that this pattern is also found with nonwords. For Experiment 3, we factorially manipulated length and neighborhood size, and found only effects of the latter. These results are problematic for any theory of memory that includes decay offset by rehearsal, but they are consistent with accounts that include a redintegrative stage that is susceptible to disruption by noise. The results also confirm the importance of lexical and linguistic factors on memory tasks thought to tap short-term memory.

  8. Correlated evolution of sternal keel length and ilium length in birds

    Directory of Open Access Journals (Sweden)

    Tao Zhao

    2017-07-01

    Full Text Available The interplay between the pectoral module (the pectoral girdle and limbs and the pelvic module (the pelvic girdle and limbs plays a key role in shaping avian evolution, but prior empirical studies on trait covariation between the two modules are limited. Here we empirically test whether (size-corrected sternal keel length and ilium length are correlated during avian evolution using phylogenetic comparative methods. Our analyses on extant birds and Mesozoic birds both recover a significantly positive correlation. The results provide new evidence regarding the integration between the pelvic and pectoral modules. The correlated evolution of sternal keel length and ilium length may serve as a mechanism to cope with the effect on performance caused by a tradeoff in muscle mass between the pectoral and pelvic modules, via changing moment arms of muscles that function in flight and in terrestrial locomotion.

  9. Note from TS/FM Group

    CERN Document Server

    2007-01-01

    Renovation work at Restaurant no. 1 Please note that starting from 5 March and for one week, the men's toilets in Bldg. 500 (underground) will be closed because of the renovation work at Restaurant No. 1. The women's toilets in the same place will exceptionally be open to men and women during the same period. We apologize for the inconvenience and we are at your disposal for further information. Shuttle requests Please note that starting from 1 March 2007, shuttle requests: for official visits or bidders' conferences on the CERN site; to/from the airport or the centre of Geneva; for long distances, must be made via Fm.Support@cern.ch or by calling 77777. The radio taxi will still be reachable on 76969. Please note that starting from 1st of March, requests for the transport of PCs from your office to the PC store (Bldg. 513) and vice-versa, must be made the 'transport request' form on EDH under the field 'removals'). Mail distribution Please note that starting from 1 March 2007, mail distrib...

  10. Comprehensive nuclear materials

    CERN Document Server

    Allen, Todd; Stoller, Roger; Yamanaka, Shinsuke

    2012-01-01

    Comprehensive Nuclear Materials encapsulates a panorama of fundamental information on the vast variety of materials employed in the broad field of nuclear technology. The work addresses, in five volumes, 3,400 pages and over 120 chapter-length articles, the full panorama of historical and contemporary international research in nuclear materials, from Actinides to Zirconium alloys, from the worlds' leading scientists and engineers. It synthesizes the most pertinent research to support the selection, assessment, validation and engineering of materials in extreme nuclear environments. The work discusses the major classes of materials suitable for usage in nuclear fission, fusion reactors and high power accelerators, and for diverse functions in fuels, cladding, moderator and control materials, structural, functional, and waste materials.

  11. Fundamental length

    International Nuclear Information System (INIS)

    Pradhan, T.

    1975-01-01

    The concept of fundamental length was first put forward by Heisenberg from purely dimensional reasons. From a study of the observed masses of the elementary particles known at that time, it is sumrised that this length should be of the order of magnitude 1 approximately 10 -13 cm. It was Heisenberg's belief that introduction of such a fundamental length would eliminate the divergence difficulties from relativistic quantum field theory by cutting off the high energy regions of the 'proper fields'. Since the divergence difficulties arise primarily due to infinite number of degrees of freedom, one simple remedy would be the introduction of a principle that limits these degrees of freedom by removing the effectiveness of the waves with a frequency exceeding a certain limit without destroying the relativistic invariance of the theory. The principle can be stated as follows: It is in principle impossible to invent an experiment of any kind that will permit a distintion between the positions of two particles at rest, the distance between which is below a certain limit. A more elegant way of introducing fundamental length into quantum theory is through commutation relations between two position operators. In quantum field theory such as quantum electrodynamics, it can be introduced through the commutation relation between two interpolating photon fields (vector potentials). (K.B.)

  12. Technical Note

    African Journals Online (AJOL)

    Administratör

    In this report on four patients, we did not use any of these techniques. The existence and the site of the fistulas was clearly demonstrated using basic but important preoperative detailed assessment and two intraoperative findings. The preoperative referral note that indicated the site of technical difficulty during the previous ...

  13. A note on axial symmetries

    International Nuclear Information System (INIS)

    Beetle, Christopher; Wilder, Shawn

    2015-01-01

    This note describes how to characterize and normalize an axial Killing field on a general Riemannian geometry or four-dimensional Lorentzian geometry. No global assumptions are necessary, such as that the orbits of the Killing field all have period 2π. Rather, any Killing field that vanishes at at least one point necessarily has the expected global properties. (note)

  14. Corrosion resistance and development length of steel reinforcement with cementitious coatings

    Science.gov (United States)

    Pei, Xiaofei

    This research program focused on the corrosion resistance and development length of reinforcing steel coated with Cementitious Capillary Crystalline Waterproofing (CCCW) materials. The first part of this research program involved using the half-cell potential method to evaluate the corrosion resistance of CCCW coating materials. One hundred and two steel bars were embedded in concrete cylinders and monitored. In total, 64 steel reinforcing bars were coated with CCCW prior to embedment, 16 mortar cylinders were externally coated with CCCW, and 22 control (uncoated) samples were tested. All the samples were immersed in a 3.5% concentration chloride solution for a period of one year. Three coating types were studied: CCCW-B, CCCW-B+ C and CCCW-C+D. The test results showed that the CCCW coating materials delayed the corrosion activity to varying degrees. In particular, CCCW-C+D applied on the reinforcing steel surface dramatically delayed the corrosion activity when compared to the control samples. After being exposed to the chloride solution for a period of one year, no sign of corrosion was observed for the cylinders where the concrete surface was coated. The second part of this research evaluated the bond strength and development length of reinforcing steel coated with two types of CCCW coating materials (CCCW-B+C and CCCW-C+D) using a modified pull-out test method. A self-reacting inverted T-shaped beam was designed to avoid compression in the concrete surrounding the reinforcing steel. Steel reinforcing bars were embedded along the web portion of the T-beam with various embedded lengths and were staggered side by side. In total, six T-beams were fabricated and each beam contained 8 samples. Both short-term (7 days) and long-term (3 months) effects of water curing were evaluated. The reinforcing steel bars coated with CCCW-B+C demonstrated a higher bond strength than did samples coated with CCCW-C+D. However, the bond strengths of samples with coating materials

  15. Localization length in a quasi-one-dimensional disordered system in the presence of an electric field

    International Nuclear Information System (INIS)

    Gasparian, Vladimir; Cahay, Marc; Jodar, Esther

    2011-01-01

    A two-dimensional δ-potential Kronig-Penney model for quasi-one-dimensional (Q1D) disordered systems is used to study analytically the influence of a constant electric field on the inverse localization length (LL). Based on the Green's function formalism we have calculated LL as a function of the incoming energy E, electric field F, length L of the Q1D sample, number of modes M in the transverse direction and the amount of disorder w. We show that, for large L in Q1D systems, states are weakly localized, i.e. we deal with power-law localization. With increasing electric field in Q1D mesoscopic systems a transition from exponential to a power-law behavior takes place, as in 1D systems. We note that the graphs showing the inverse LL change significantly with increasing F (for fixed M) rather than with increasing M (for fixed F). We also show that the graphs representing the ratio of the corresponding localization length without and with electric field collapse for all modes M into a universal curve in the Q1D strip model.

  16. Influence of the length of institutionalization on older adults' postural balance and risk of falls: a transversal study

    Directory of Open Access Journals (Sweden)

    Wagner Oliveira Batista

    2014-08-01

    Full Text Available OBJECTIVE: to ascertain the influence of the length of institutionalization on older adults' balance and risk of falls.METHOD: to evaluate the risk of falls, the Berg Balance Scale and the Timed Get Up and Go test were used; and for measuring postural balance, static stabilometry was used, with acquisition of the elliptical area of 95% and mean velocities on the x and y axes of center of pressure displacement. Parametric and nonparametric measures of association and comparison (α<0.05 were used.RESULTS: there was no significant correlation between the length of institutionalization and the tests for evaluation of risk of falling, neither was there difference between groups and within subgroups, stratified by length of institutionalization and age. In the stabilometric measurements, there was a negative correlation between the parameters analyzed and the length of institutionalization, and difference between groups and within subgroups.CONCLUSION: this study's results point to the difficulty of undertaking postural control tasks, showing a leveling below the clinical tests' reference scores. In the stabilometric behavior, one should note the reduction of the parameters as the length of institutionalization increases, contradicting the assumptions. This study's results offer support for the development of a multi-professional model for intervention with the postural control and balance of older adults living in homes for the aged.

  17. Concept study: Use of grout vaults for disposal of long-length contaminated equipment

    International Nuclear Information System (INIS)

    Clem, D.K.

    1994-01-01

    Study considers the potential for use of grout vaults for disposal of untreated long length equipment removed from waste tanks. Looks at ways to access vaults, material handling, regulatory aspects, and advantages and disadvantages of vault disposal

  18. Influence of the length of institutionalization on older adults' postural balance and risk of falls: a transversal study1

    Science.gov (United States)

    Batista, Wagner Oliveira; Alves, Edmundo de Drummond; Porto, Flávia; Pereira, Fabio Dutra; Santana, Rosimere Ferreira; Gurgel, Jonas Lírio

    2014-01-01

    OBJECTIVE: to ascertain the influence of the length of institutionalization on older adults' balance and risk of falls. METHOD: to evaluate the risk of falls, the Berg Balance Scale and the Timed Get Up and Go test were used; and for measuring postural balance, static stabilometry was used, with acquisition of the elliptical area of 95% and mean velocities on the x and y axes of center of pressure displacement. Parametric and nonparametric measures of association and comparison (αrisk of falling, neither was there difference between groups and within subgroups, stratified by length of institutionalization and age. In the stabilometric measurements, there was a negative correlation between the parameters analyzed and the length of institutionalization, and difference between groups and within subgroups. CONCLUSION: this study's results point to the difficulty of undertaking postural control tasks, showing a leveling below the clinical tests' reference scores. In the stabilometric behavior, one should note the reduction of the parameters as the length of institutionalization increases, contradicting the assumptions. This study's results offer support for the development of a multi-professional model for intervention with the postural control and balance of older adults living in homes for the aged. PMID:25296149

  19. What Predicts Skill in Lecture Note Taking?

    Science.gov (United States)

    Peverly, Stephen T.; Ramaswamy, Vivek; Brown, Cindy; Sumowski, James; Alidoost, Moona; Garner, Joanna

    2007-01-01

    Despite the importance of good lecture notes to test performance, very little is known about the cognitive processes that underlie effective lecture note taking. The primary purpose of the 2 studies reported (a pilot study and Study 1) was to investigate 3 processes hypothesized to be significantly related to quality of notes: transcription…

  20. Editor's Note

    African Journals Online (AJOL)

    On another note: the editor and the editorial team acknowledge the financial support of the Carnegie Corporation of New York through the University of Ghana Building A New Generation of Academics in Africa (BANGA-Africa) Project. We also use this platform to express our gratitude for the support of various stakeholders, ...

  1. Note-taking and Handouts in The Digital Age.

    Science.gov (United States)

    Stacy, Elizabeth Moore; Cain, Jeff

    2015-09-25

    Most educators consider note-taking a critical component of formal classroom learning. Advancements in technology such as tablet computers, mobile applications, and recorded lectures are altering classroom dynamics and affecting the way students compose and review class notes. These tools may improve a student's ability to take notes, but they also may hinder learning. In an era of dynamic technology developments, it is important for educators to routinely examine and evaluate influences on formal and informal learning environments. This paper discusses key background literature on student note-taking, identifies recent trends and potential implications of mobile technologies on classroom note-taking and student learning, and discusses future directions for note-taking in the context of digitally enabled lifelong learning.

  2. Taking notes as an interactive process

    OpenAIRE

    Hornig, Wolfgang

    1984-01-01

    Taking notes as an interactive process : how to improve students´ notes / Hornig W. ; Nowak, J. - In: Nowak, Johann: Textverstehen und Textrekonstruktion in Vorlesungen. - Augsburg : HDZ, 1984. - S. 227-253. - (Augsburger Studien zur Hochschuldidaktik ; 12)

  3. Stress Mapping in Glass-to-Metal Seals using Indentation Crack Lengths.

    Energy Technology Data Exchange (ETDEWEB)

    Strong, Kevin [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Buchheit, Thomas E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Diebold, Thomas Wayne [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Newton, Clay S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bencoe, Denise N. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Stavig, Mark E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jamison, Ryan Dale [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-08-01

    Predicting the residual stress which develops during fabrication of a glass-to-metal compression seal requires material models that can accurately predict the effects of processing on the sealing glass. Validation of the predictions requires measurements on representative test geometries to accurately capture the interaction between the seal materials during a processing cycle required to form the seal, which consists of a temperature excursion through the glass transition temperature of the sealing glass. To this end, a concentric seal test geometry, referred to as a short cylinder seal, consisting of a stainless steel shell enveloping a commercial sealing glass disk has been designed, fabricated, and characterized as a model validation test geometry. To obtain data to test/validate finite element (FE) stress model predictions of this geometry, spatially-resolved residual stress was calculated from the measured lengths of the cracks emanating from radially positioned Vickers indents in the glass disk portion of the seal. The indentation crack length method is described, and the spatially-resolved residual stress determined experimentally are compared to FE stress predictions made using a nonlinear viscoelastic material model adapted to inorganic sealing glasses and an updated rate dependent material model for 304L stainless steel. The measurement method is a first to achieve a degree of success for measuring spatially resolved residual stress in a glass-bearing geometry and a favorable comparison between measurements and simulation was observed.

  4. Stress Mapping in Glass-to-Metal Seals using Indentation Crack Lengths

    Energy Technology Data Exchange (ETDEWEB)

    Buchheit, Thomas E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Component & Systems Analysis; Strong, Kevin [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Material Mechanics and Tribology; Newton, Clay S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Material Mechanics and Tribology; Diebold, Thomas Wayne [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Material Mechanics and Tribology; Bencoe, Denise N. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Electronic, Optical and Nano; Stavig, Mark E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Organic Materials Science; Jamison, Ryan Dale [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Transportation System Analysis

    2017-08-01

    Predicting the residual stress which develops during fabrication of a glass-to-metal compression seal requires material models that can accurately predict the effects of processing on the sealing glass. Validation of the predictions requires measurements on representative test geometries to accurately capture the interaction between the seal materials during a processing cycle required to form the seal, which consists of a temperature excursion through the glass transition temperature of the sealing glass. To this end, a concentric seal test geometry, referred to as a short cylinder seal, consisting of a stainless steel shell enveloping a commercial sealing glass disk has been designed, fabricated, and characterized as a model validation test geometry. To obtain data to test/validate finite element (FE) stress model predictions of this geometry, spatially-resolved residual stress was calculated from the measured lengths of the cracks emanating from radially positioned Vickers indents in the glass disk portion of the seal. The indentation crack length method is described, and the spatially-resolved residual stress determined experimentally are compared to FE stress predictions made using a nonlinear viscoelastic material model adapted to inorganic sealing glasses and an updated rate dependent material model for 304L stainless steel. The measurement method is a first to achieve a degree of success for measuring spatially resolved residual stress in a glass-bearing geometry and a favorable comparison between measurements and simulation was observed.

  5. Grouping Notes Through Nodes

    DEFF Research Database (Denmark)

    Dove, Graham; Abildgaard, Sille Julie Jøhnk; Biskjær, Michael Mose

    , both individually and when grouped, and their role in categorisation in semantic long-term memory. To do this, we adopt a multimodal analytical approach focusing on interaction between humans, and between humans and artefacts, alongside language. We discuss in detail examples of four different...... externalisation functions served by Post-ItTM notes, and show how these functions are present in complex overlapping combinations rather than being discrete. We then show how the temporal development of Post-ItTM note interactions supports categorisation qualities of semantic long-term memory....

  6. Grouping Notes Through Nodes

    DEFF Research Database (Denmark)

    Dove, Graham; Abildgaard, Sille Julie; Biskjær, Michael Mose

    2017-01-01

    , both individually and when grouped, and their role in categorisation in semantic long-term memory. To do this, we adopt a multimodal analytical approach focusing on interaction between humans, and between humans and artefacts, alongside language. We discuss in detail examples of four different...... externalisation functions served by Post-ItTM notes, and show how these functions are present in complex overlapping combinations rather than being discrete. We then show how the temporal development of Post-ItTM note interactions supports categorisation qualities of semantic long-term memory....

  7. The Effects of Cognitive Strategies i.e. Note-Making and Underlining on Iranian EFL Learners’ Reading Comprehension

    Directory of Open Access Journals (Sweden)

    Amir Mahdavi

    2012-11-01

    Full Text Available The purpose of this study was to investigate the effects of using cognitive strategies namely note- making and underlining, on Iranian EFL learners’ reading comprehension. In doing so, 60 female fourth year high school EFL learners were selected by means of the NELSON test (050A. They were then divided randomly into three groups, each group consisting of 20 homogeneous students: two experimental groups, and one control group. The experimental groups practiced note making (group A and underlining reading strategies (group B on the same reading materials while the control group received the placebo. Then, all the subjects in the three groups took the same reading comprehension test. The results of a One-way Analysis of Variance (ANOVA and a post-hoc analysis of the Scheffe test showed that the learners who utilized note-making and underlining strategies outperformed the control group (p<.05. Furthermore, the experimental group who received note-making instruction revealed a higher efficiency than underlining group. As a result it can be concluded that note making and underlining have had positive effects on students’ rate of reading comprehensibility.

  8. Debriefing Note Secondary Education Support Programme

    DEFF Research Database (Denmark)

    Webster, Neil; Vagnby, Bo Hellisen; Thomsen, Thomas J.

    Debriefing note regarding joint programming for the Secondary Education Support Programme (2003- 2007). The note specifies preparation of SIP Physical Guidelines; Training needs assessment for Physical School Status and Rapid Technical Assessments; SIP/DEP preparation; Selection criteria...

  9. Dependence of Exciton Diffusion Length and Diffusion Coefficient on Photophysical Parameters in Bulk Heterojunction Organic Solar Cells

    Science.gov (United States)

    Yeboah, Douglas; Singh, Jai

    2017-11-01

    Recently, the dependence of exciton diffusion length (LD ) on some photophysical parameters of organic solids has been experimentally demonstrated, however no systematic theoretical analysis of this phenomenon has been carried out. We have conducted a theoretical study by using the Förster resonance energy transfer and Dexter carrier transfer mechanisms together with the Einstein-Smoluchowski diffusion equation to derive analytical models for the diffusion lengths (LD ) and diffusion coefficients (D) of singlet (S) and triplet (T) excitons in organic solids as functions of spectral overlap integral (J) , photoluminescence (PL) quantum yield (φD ) , dipole moment (μT ) and refractive index (n) of the photoactive material. The exciton diffusion lengths and diffusion coefficients in some selected organic solids were calculated, and we found that the singlet exciton diffusion length (LDS ) increases with φD and J, and decreases with n. Also, the triplet exciton diffusion length (LDT ) increases with φD and decreases with μT . These may be achieved through doping the organic solids into broad optical energy gap host materials as observed in previous experiments. The calculated exciton diffusion lengths are compared with experimental values and a reasonably good agreement is found between them. The results presented are expected to provide insight relevant to the synthesis of new organic solids for fabrication of bulk heterojunction organic solar cells characterized by better power conversion efficiency.

  10. How to write cases and teaching notes in marketing education?

    Directory of Open Access Journals (Sweden)

    Damnjanović Vesna

    2017-01-01

    Full Text Available This paper presents guidelines for developing cases and teaching notes for marketing classes in higher education. Cases are often used in problem-based learning, where students are placed in a problem or decision-making situation and are encouraged to take the role of problem solvers. The recommendations for case writing are based on analysis of high-level examples of marketing cases, published in the most prominent global publishing databases, along with more than 15 years of experience of the authors. This paper explains the process of writing cases depending on the source of data and tackles all necessary issues that should be addressed. Writing teaching notes is focused on providing the supportive material for a case that helps a lecturer understand the reason for writing the case, the questions that might arise from it and the professional or theoretical points that should be raised in discussion. This paper should contribute to interactive learning and provide lecturers with detailed recommendations for writing cases in the marketing field.

  11. Research note: Mapping spatial patterns in sewer age, material, and proximity to surface waterways to infer sewer leakage hotspots

    Science.gov (United States)

    Hopkins, Kristina G.; Bain, Daniel J.

    2018-01-01

    Identifying areas where deteriorating sewer infrastructure is in close proximity to surface waterways is needed to map likely connections between sewers and streams. We present a method to estimate sewer installation year and deterioration status using historical maps of the sewer network, parcel-scale property assessment data, and pipe material. Areas where streams were likely buried into the sewer system were mapped by intersecting the historical stream network derived from a 10-m resolution digital elevation model with sewer pipe locations. Potential sewer leakage hotspots were mapped by identifying where aging sewer pipes are in close proximity (50-m) to surface waterways. Results from Pittsburgh, Pennsylvania (USA), indicated 41% of the historical stream length was lost or buried and the potential interface between sewers and streams is great. The co-location of aging sewer infrastructure (>75 years old) near stream channels suggests that 42% of existing streams are located in areas with a high potential for sewer leakage if sewer infrastructure fails. Mapping the sewer-stream interface provides an approach to better understand areas were failing sewers may contribute a disproportional amount of nutrients and other pathogens to surface waterways.

  12. Technical specifications (replaces note T.62). Irradiation of graphite at ambient temperature, Note T. 76; Specification technique, (Annule et remplace la note T. 62), Irradiation de graphite a temperature ambiante, Note T. 76

    Energy Technology Data Exchange (ETDEWEB)

    Reseau, R A [Services des grandes piles experimentales, Section ' Physique et Experimentation, Saclay (France)

    1962-12-15

    The objective is to study the effects of fast neutron irradiation of different graphite samples. The irradiation conditions should be as follows: integral fast neutron flux should be higher than 10{sup 20} neutrons/cm{sup 2}, the reactor should operate at steady state for 15 days, the temperature od samples should not be higher than 100 deg C, preferably 80 deg C. Note T. 62 which is replaced by this Note is attached.

  13. A simple method for estimating the length density of convoluted tubular systems.

    Science.gov (United States)

    Ferraz de Carvalho, Cláudio A; de Campos Boldrini, Silvia; Nishimaru, Flávio; Liberti, Edson A

    2008-10-01

    We present a new method for estimating the length density (Lv) of convoluted tubular structures exhibiting an isotropic distribution. Although the traditional equation Lv=2Q/A is used, the parameter Q is obtained by considering the collective perimeters of tubular sections. This measurement is converted to a standard model of the structure, assuming that all cross-sections are approximately circular and have an average perimeter similar to that of actual circular cross-sections observed in the same material. The accuracy of this method was tested in eight experiments using hollow macaroni bent into helical shapes. After measuring the length of the macaroni segments, they were boiled and randomly packed into cylindrical volumes along with an aqueous suspension of gelatin and India ink. The solidified blocks were cut into slices 1.0 cm thick and 33.2 cm2 in area (A). The total perimeter of the macaroni cross-sections so revealed was stereologically estimated using a test system of straight parallel lines. Given Lv and the reference volume, the total length of macaroni in each section could be estimated. Additional corrections were made for the changes induced by boiling, and the off-axis position of the thread used to measure length. No statistical difference was observed between the corrected estimated values and the actual lengths. This technique is useful for estimating the length of capillaries, renal tubules, and seminiferous tubules.

  14. 15 CFR Notes Applicable to State... - Notes applicable to State of Understanding related to Medical Equipment:

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Notes applicable to State of Understanding related to Medical Equipment: applicable Notes applicable to State of Understanding related to Medical Equipment: Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY,...

  15. Notes on Loricata (Mollusca) 11-14

    NARCIS (Netherlands)

    Kaas, P.

    1985-01-01

    Four new species of chitons (Mollusca, Polyplacophora) are described, viz Leptochiton (L.) dispersus and L. (L.) permodestus from Transkei, L. (L.) meiringae from the eastern Cape Province, S Africa (note 11) and Ischnochiton (Stenosemus) vanbellei from the Mediterranean Sea (note 14). New records

  16. Writing a technical note.

    Science.gov (United States)

    Ng, K H; Peh, W C G

    2010-02-01

    A technical note is a short article giving a brief description of a specific development, technique or procedure, or it may describe a modification of an existing technique, procedure or device applicable to medicine. The technique, procedure or device described should have practical value and should contribute to clinical diagnosis or management. It could also present a software tool, or an experimental or computational method. Technical notes are variously referred to as technical innovations or technical developments. The main criteria for publication will be the novelty of concepts involved, the validity of the technique and its potential for clinical applications.

  17. New-Onset Depression Following Hip Fracture Is Associated With Increased Length of Stay in Hospital and Rehabilitation Centers

    Directory of Open Access Journals (Sweden)

    Anna C. Phillips

    2015-05-01

    Full Text Available This article examines the coincident effects of new-onset depression post hip fracture on length of hospital stay, readmission rates, and incidence of infections in older adults. Participants were 101 hip fracture patients aged 60+ years; 38 developed depressive symptoms following their fracture. Infection rates, readmissions to hospital and rehabilitation units, and length of hospital stay were assessed over the 6 months post hip fracture from hospital and general practitioner notes. Patients who developed depression by Week 6 post fracture were likely to spend more time in hospital/rehabilitation wards (p = .02 and more likely to be discharged to a rehabilitation unit (p < .05. There were no group differences in readmissions or infection rates. New-onset depression coincident with hip fracture in older adults is associated with longer hospital ward stays and greater need for rehabilitation.

  18. Electronic property measurements for piezoelectric ceramics. Technical notes

    International Nuclear Information System (INIS)

    Cain, M.; Stewart, M.; Gee, M.

    1998-01-01

    A series of measurement notes are presented, with emphasis placed on the technical nature of the testing methodology, for the determination of key electronic properties for piezoelectric ceramic materials that are used as sensors and actuators. The report is segmented into 'sections' that may be read independently from the rest of the report. The following measurement issues are discussed: Polarisation/Electric field (PE) loop measurements including a discussion of commercial and an in-house constructed system that measures PE loops; Dielectric measurements at low and high stress application, including some thermal and stress dependency modelling of piezo materials properties, developed at NPL; Strain measurement techniques developed at CMMT; Charge measurement techniques suitable for PE loop and other data acquisition; PE loop measurement and software analysis developed at CMMT and Manchester University. The primary objective of this report is to provide a framework on which the remainder of the testing procedures are to be developed for measurements of piezoelectric properties at high stress and stress rate. These procedures will be the subject of a future publication. (author)

  19. Long-term microwaving of denture base materials: effects on dimensional, color and translucency stability

    Directory of Open Access Journals (Sweden)

    Nick POLYCHRONAKIS

    2018-06-01

    Full Text Available Abstract While the combined effect of microwave irradiation with cleansing solutions on denture base materials has been investigated, the effects of only using microwave irradiation and, more importantly, in a long-term basis, was not studied yet. Objective The purpose of this study was to evaluate the effect of a long-term repeated microwaving on the dimensional, color and translucency stability of acrylic and polyamide denture base materials. Material and Methods Thirty two specimens (32 mm x 10 mm x 2.5 mm from polyamide (Valplast and PMMA (Vertex Rapid Simplified denture base materials were made. Eight specimens from each material were immersed in distilled water (control and 8 were subjected to microwave exposure at 450 W for 3 minutes for a period simulating 224 days of daily disinfection. Linear dimension, color change (ΔE* and translucency parameter (TP were measured at baseline and after certain intervals up to 224 cycles of immersion, using a digital calliper and a portable colorimeter. The results were analysed using two-way repeated measures ANOVA to estimate possible differences among predetermined cycles and material type. Regression analysis was also performed to estimate the trend of changes with time. Statistical evaluations performed at a significance level of 5%. Results Data analysis showed significant changes in length at baseline with an increasing number of cycles (p0.05. TP decreased similarly in both materials following microwave action but in a significantly higher level for Valplast (p<0.001. Conclusions The results indicated that long-term repeated microwaving affects linear dimensional, color and translucency changes of both materials. Differences between PMMA and polyamide material were noted only in dimension and translucency changes.

  20. Austenite Grain Size Estimtion from Chord Lengths of Logarithmic-Normal Distribution

    Directory of Open Access Journals (Sweden)

    Adrian H.

    2017-12-01

    Full Text Available Linear section of grains in polyhedral material microstructure is a system of chords. The mean length of chords is the linear grain size of the microstructure. For the prior austenite grains of low alloy structural steels, the chord length is a random variable of gamma- or logarithmic-normal distribution. The statistical grain size estimation belongs to the quantitative metallographic problems. The so-called point estimation is a well known procedure. The interval estimation (grain size confidence interval for the gamma distribution was given elsewhere, but for the logarithmic-normal distribution is the subject of the present contribution. The statistical analysis is analogous to the one for the gamma distribution.

  1. Neighborhood Disadvantage and Telomere Length: Results from the Fragile Families Study

    Directory of Open Access Journals (Sweden)

    Douglas S. Massey

    2018-04-01

    Full Text Available Telomeres are repetitive nucleotide sequences located at the ends of chromosomes that protect genetic material. We use data from the Fragile Families and Child Wellbeing Study to analyze the relationship between exposure to spatially concentrated disadvantage and telomere length for white and black mothers. We find that neighborhood disadvantage is associated with shorter telomere length for mothers of both races. This finding highlights a potential mechanism through which the unique spatially concentrated disadvantage faced by African Americans contributes to racial health disparities. We conclude that equalizing the health and socioeconomic status of black and white Americans will be very difficult without reducing levels of residential segregation in the United States.

  2. SAFETY INSTRUCTION AND SAFETY NOTE

    CERN Multimedia

    TIS Secretariat

    2002-01-01

    Please note that the SAFETY INSTRUCTION N0 49 (IS 49) and the SAFETY NOTE N0 28 (NS 28) entitled respectively 'AVOIDING CHEMICAL POLLUTION OF WATER' and 'CERN EXHIBITIONS - FIRE PRECAUTIONS' are available on the web at the following urls: http://edms.cern.ch/document/335814 and http://edms.cern.ch/document/335861 Paper copies can also be obtained from the TIS Divisional Secretariat, email: TIS.Secretariat@cern.ch

  3. Root Length and Anatomy of Impacted Maxillary Canines in Patients with Unilateral Maxillary Canine Impaction

    OpenAIRE

    Mostfa Shahabi; Maryam Omidkhoda; Seyedeh Haniyeh Omidi; Seyed Hosein Hoseini Zarch

    2017-01-01

    Introduction: Canine impaction is a common occurrence. In this study, we sought to investigate the root anatomy and length of impacted canines and lateral incisor adjacent to impacted maxillary canine. Materials and Methods: In this retrospective study, three-dimensional tomographic imaging was performed on 26 patients with unilateral maxillary canine impaction. In this study, we evaluated root length and anatomy of impacted canines, in terms of resorption intensity and curvature, with Planme...

  4. Enhanced Strain in Functional Nanoporous Gold with a Dual Microscopic Length Scale Structure

    NARCIS (Netherlands)

    Detsi, Eric; Punzhin, Sergey; Rao, Jiancun; Onck, Patrick R.; De Hosson, Jeff Th. M.

    We have synthesized nanoporous Au with a dual microscopic length scale by exploiting the crystal structure of the alloy precursor. The synthesized mesoscopic material is characterized by stacked Au layers of submicrometer thickness. In addition, each layer displays nanoporosity through the entire

  5. Changes in root lengths of maxillary incisors during orthodontic retention period

    Directory of Open Access Journals (Sweden)

    Ravanmehr H

    2006-01-01

    Full Text Available Background and Aim: External apical root resorption is a common iatrogenic consequence of orthodontic treatment. Much controversy exists in the literature about changes in root lengths at post treatment periods. Although many practitioners believe that resorption becomes stable after active treatment, quantitative data are scarce. The purpose of this study was to determine quantitative changes in root lengths of maxillary incisors during fixed orthodontic post treatment period, and to assess if it is influenced by gender and factors related to active treatment. Materials and Methods: This was a case cross over study, performed on 80 patients (52 females and 28 males aged between 13 and 22 years. At debonding stage and beginning of retention phase of fixed orthodontic treatment, Hawley type retainer was fabricated for maxillary arch. Periapical radiographs of maxillary incisors using standard parallel technique were obtained immediately after debonding, and 3 and 7 months later. Crown and root lengths of maxillary incisors were measured using computer program. Changes in root lengths were calculated considering correction factors. Also associations between some factors and the change in root lengths during post treatment periods were assessed. These included gender, type of treatment plan (non extraction/extraction, technique (standard edgewise/straight-wire edgewise and duration of active treatment (less than 2 years/2 years and more. T-test and 4-way ANOVA were used for statistical analysis with P0.05 as the limit of significance. Results: No significant relation was found between apical root resorption of maxillary central incisors and time elapsed after treatment. Significant relation was observed between apical root resorption of maxillary lateral incisors and the length of post treatment period. No significant relation was found between root length changes of maxillary incisors during post treatment period and gender, type of treatment

  6. Does length of common limb influence remission of diabetes? Short-term results

    Directory of Open Access Journals (Sweden)

    Ramraj V Nagendra Gupta

    2016-01-01

    Full Text Available Background: Despite strict patient selection criteria, diabetes remission is not seen in all patients after gastric bypass. Can length of the common limb influence diabetes remission? Aim: To find if any correlation exists between the length of the common limb and remission of diabetes. Study Design: Prospective study. Materials and Methods: Twenty-five consecutive patients with Type II diabetes mellitus and a fasting C-peptide >1 ng/ml who underwent laparoscopic Roux-en-y gastric bypass were included. All patients had standard limb lengths and length of the common limb was measured in all patients. Patients were followed up and glycated haemoglobin (HbA1c was repeated at 6 months postoperatively. Pre- and postoperative HbA1c were then correlated with the lengths of common limb to look for any relation. Statistical Analysis: Descriptive and inferential statistical analysis, analysis of variance (ANOVA. Results: Of the 25 patients, 15 were females and 10 were males. The mean age was 44.16 years and the mean body mass index (BMI was 43.96 kg/m 2 . Preoperative HbA1c varied from 5.8 to 12.3%. Length of the common limb varied from 210 to 790 cm (mean 470.4 cm. HbA1c at 6 months ranged from 4.8 to 7.7% (mean 5.81%. On comparison of preoperative and 6 months postoperative HbA1c and correlating with the length of common limb, we found that patients with a common limb of length 600 cm length (P = 0.004. Conclusion: A shorter common limb does appear to have better chances of resolution of Type II diabetes mellitus in our study, thus paving the way for further studies.

  7. Please note

    CERN Multimedia

    2006-01-01

    Members of the personnel are invited to take note that only parcels corresponding to official orders or contracts will be handled at CERN. Individuals are not authorised to have private merchandise delivered to them at CERN and private deliveries will not be accepted by the Goods Reception services. Thank you for your understanding. (Version française la semaine prochaine.)

  8. Generation of Length Distribution, Length Diagram, Fibrogram, and Statistical Characteristics by Weight of Cotton Blends

    Directory of Open Access Journals (Sweden)

    B. Azzouz

    2007-01-01

    Full Text Available The textile fibre mixture as a multicomponent blend of variable fibres imposes regarding the proper method to predict the characteristics of the final blend. The length diagram and the fibrogram of cotton are generated. Then the length distribution, the length diagram, and the fibrogram of a blend of different categories of cotton are determined. The length distributions by weight of five different categories of cotton (Egyptian, USA (Pima, Brazilian, USA (Upland, and Uzbekistani are measured by AFIS. From these distributions, the length distribution, the length diagram, and the fibrogram by weight of four binary blends are expressed. The length parameters of these cotton blends are calculated and their variations are plotted against the mass fraction x of one component in the blend .These calculated parameters are compared to those of real blends. Finally, the selection of the optimal blends using the linear programming method, based on the hypothesis that the cotton blend parameters vary linearly in function of the components rations, is proved insufficient.

  9. 19 CFR 10.455 - Value of materials.

    Science.gov (United States)

    2010-04-01

    ... Chile or of the United States. (c) Accounting method. Any cost or value referenced in General Note 26(n... 19 Customs Duties 1 2010-04-01 2010-04-01 false Value of materials. 10.455 Section 10.455 Customs... of Origin § 10.455 Value of materials. (a) Calculating the regional value content. For purposes of...

  10. Regulations for the safe transport of radioactive materials. Notes on certain aspects of the regulations

    International Nuclear Information System (INIS)

    1961-01-01

    The notes attempt to provide some broad general guidance to users as to the purpose of the regulations and their working out in practice. They contain also the scientific background to the classification of radioisotopes for transport purposes given in the regulations. Furthermore, an approach was made to the difficult question of design of containers in relation to the factors that have to be taken into account by competent authorities in approving Type B containers, with a view both to helping those concerned on both sides of this transport problem, and to stimulating further thought on the subject, in order to build up a corpus of practical experience in this field.

  11. Telomere length modulation in human astroglial brain tumors.

    Directory of Open Access Journals (Sweden)

    Domenico La Torre

    Full Text Available BACKGROUND: Telomeres alteration during carcinogenesis and tumor progression has been described in several cancer types. Telomeres length is stabilized by telomerase (h-TERT and controlled by several proteins that protect telomere integrity, such as the Telomere Repeat-binding Factor (TRF 1 and 2 and the tankyrase-poli-ADP-ribose polymerase (TANKs-PARP complex. OBJECTIVE: To investigate telomere dysfunction in astroglial brain tumors we analyzed telomeres length, telomerase activity and the expression of a panel of genes controlling the length and structure of telomeres in tissue samples obtained in vivo from astroglial brain tumors with different grade of malignancy. MATERIALS AND METHODS: Eight Low Grade Astrocytomas (LGA, 11 Anaplastic Astrocytomas (AA and 11 Glioblastoma Multiforme (GBM samples were analyzed. Three samples of normal brain tissue (NBT were used as controls. Telomeres length was assessed through Southern Blotting. Telomerase activity was evaluated by a telomere repeat amplification protocol (TRAP assay. The expression levels of TRF1, TRF2, h-TERT and TANKs-PARP complex were determined through Immunoblotting and RT-PCR. RESULTS: LGA were featured by an up-regulation of TRF1 and 2 and by shorter telomeres. Conversely, AA and GBM were featured by a down-regulation of TRF1 and 2 and an up-regulation of both telomerase and TANKs-PARP complex. CONCLUSIONS: In human astroglial brain tumours, up-regulation of TRF1 and TRF2 occurs in the early stages of carcinogenesis determining telomeres shortening and genomic instability. In a later stage, up-regulation of PARP-TANKs and telomerase activation may occur together with an ADP-ribosylation of TRF1, causing a reduced ability to bind telomeric DNA, telomeres elongation and tumor malignant progression.

  12. Word length, set size, and lexical factors: Re-examining what causes the word length effect.

    Science.gov (United States)

    Guitard, Dominic; Gabel, Andrew J; Saint-Aubin, Jean; Surprenant, Aimée M; Neath, Ian

    2018-04-19

    The word length effect, better recall of lists of short (fewer syllables) than long (more syllables) words has been termed a benchmark effect of working memory. Despite this, experiments on the word length effect can yield quite different results depending on set size and stimulus properties. Seven experiments are reported that address these 2 issues. Experiment 1 replicated the finding of a preserved word length effect under concurrent articulation for large stimulus sets, which contrasts with the abolition of the word length effect by concurrent articulation for small stimulus sets. Experiment 2, however, demonstrated that when the short and long words are equated on more dimensions, concurrent articulation abolishes the word length effect for large stimulus sets. Experiment 3 shows a standard word length effect when output time is equated, but Experiments 4-6 show no word length effect when short and long words are equated on increasingly more dimensions that previous demonstrations have overlooked. Finally, Experiment 7 compared recall of a small and large neighborhood words that were equated on all the dimensions used in Experiment 6 (except for those directly related to neighborhood size) and a neighborhood size effect was still observed. We conclude that lexical factors, rather than word length per se, are better predictors of when the word length effect will occur. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  13. Void growth to coalescence in a non-local material

    DEFF Research Database (Denmark)

    Niordson, Christian Frithiof

    of different material length parameters in a multi-parameter theory is studied, and it is shown that the important length parameter is the same as under purely hydrostatic loading. It is quantified how micron scale voids grow less rapidly than larger voids, and the implications of this in the overall strength...... of the material is emphasized. It is concluded that for cracked specimens not only the void volume fraction, but also the typical void size is of importance to the fracture strength of ductile materials....

  14. Electronic health records improve clinical note quality.

    Science.gov (United States)

    Burke, Harry B; Sessums, Laura L; Hoang, Albert; Becher, Dorothy A; Fontelo, Paul; Liu, Fang; Stephens, Mark; Pangaro, Louis N; O'Malley, Patrick G; Baxi, Nancy S; Bunt, Christopher W; Capaldi, Vincent F; Chen, Julie M; Cooper, Barbara A; Djuric, David A; Hodge, Joshua A; Kane, Shawn; Magee, Charles; Makary, Zizette R; Mallory, Renee M; Miller, Thomas; Saperstein, Adam; Servey, Jessica; Gimbel, Ronald W

    2015-01-01

    The clinical note documents the clinician's information collection, problem assessment, clinical management, and its used for administrative purposes. Electronic health records (EHRs) are being implemented in clinical practices throughout the USA yet it is not known whether they improve the quality of clinical notes. The goal in this study was to determine if EHRs improve the quality of outpatient clinical notes. A five and a half year longitudinal retrospective multicenter quantitative study comparing the quality of handwritten and electronic outpatient clinical visit notes for 100 patients with type 2 diabetes at three time points: 6 months prior to the introduction of the EHR (before-EHR), 6 months after the introduction of the EHR (after-EHR), and 5 years after the introduction of the EHR (5-year-EHR). QNOTE, a validated quantitative instrument, was used to assess the quality of outpatient clinical notes. Its scores can range from a low of 0 to a high of 100. Sixteen primary care physicians with active practices used QNOTE to determine the quality of the 300 patient notes. The before-EHR, after-EHR, and 5-year-EHR grand mean scores (SD) were 52.0 (18.4), 61.2 (16.3), and 80.4 (8.9), respectively, and the change in scores for before-EHR to after-EHR and before-EHR to 5-year-EHR were 18% (pquality scores significantly improved over the 5-year time interval. The EHR significantly improved the overall quality of the outpatient clinical note and the quality of all its elements, including the core and non-core elements. To our knowledge, this is the first study to demonstrate that the EHR significantly improves the quality of clinical notes. © The Author 2014. Published by Oxford University Press on behalf of the American Medical Informatics Association.

  15. Notes on Contributors

    African Journals Online (AJOL)

    NOTES ON CONTRIBUTORS. Samuel AMOAKO, Associate Researcher, South African Research Unit in Social Change. Contact Details: C/o Lucinda Bercony, Humanities Research Village (House No. 3). University of Johannesburg, P. O. Box 524. Bunting Road Campus, Auckland Park, 2006.

  16. Computational simulation of materials notes for lectures given at UCSB, May 1996--June 1996

    Energy Technology Data Exchange (ETDEWEB)

    LeSar, R.

    1997-01-01

    This report presents information from a lecture given on the computational simulation of materials. The purpose is to introduce modern computerized simulation methods for materials properties and response.

  17. Post-material values and environmental policy change

    Energy Technology Data Exchange (ETDEWEB)

    Watts, N. (International Inst. for Environmental and Society, Berlin, Germany); Wandesforde-Smith, G.

    Environmental policy may be particularly suited as a vehicle to articulate post-material values in advanced industrial societies, and recognition of this is likely to prove enormously helpful in future comparative and cross-national research into the origins of environmentalism and the causes of environmental policy change. The paper notes the salient characteristics of post-materialism and the overlap of these with the leading indicators of environmentalism. Possible structural causes for this overlap are noted and opposed to the prevailing socialization explanation for the adoption of post-material and environmental values. To help understand the impact of environmentalism on policy, an idealized development of the movement is sketched. This leads to the description of a set of general factors likely to be related to the way environmentalism finds political expressions in various countries. In the final section, the focus is on what we might want to know about the policy process in order to be able to gauge environmentalist influence on policy outputs. 20 references.

  18. Influence of crack length on crack depth measurement by an alternating current potential drop technique

    International Nuclear Information System (INIS)

    Raja, Manoj K; Mahadevan, S; Rao, B P C; Behera, S P; Jayakumar, T; Raj, Baldev

    2010-01-01

    An alternating current potential drop (ACPD) technique is used for sizing depth of surface cracks in metallic components. Crack depth estimations are prone to large deviations when ACPD measurements are made on very shallow and finite length cracks, especially in low conducting materials such as austenitic stainless steel (SS). Detailed studies have been carried out to investigate the influence of crack length and aspect ratio (length to depth) on depth estimation by performing measurements on electric discharge machined notches with the aspect ratio in the range of 1 to 40 in SS plates. In notches with finite length, an additional path for current to flow through the surface along the length is available causing the notch depths to be underestimated. The experimentally observed deviation in notch depth estimates is explained from a simple mathematical approach using the equivalent resistive circuit model based on the additional path available for the current to flow. A scheme is proposed to accurately measure the depth of cracks with finite lengths in SS components

  19. Gap length distributions by PEPR

    International Nuclear Information System (INIS)

    Warszawer, T.N.

    1980-01-01

    Conditions guaranteeing exponential gap length distributions are formulated and discussed. Exponential gap length distributions of bubble chamber tracks first obtained on a CRT device are presented. Distributions of resulting average gap lengths and their velocity dependence are discussed. (orig.)

  20. Bulletin of Materials Science | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science. Murali Sastry. Articles written in Bulletin of Materials Science. Volume 23 Issue 3 June 2000 pp 159-163 Nanomaterials. A note on the use of ellipsometry for studying the kinetics of formation of self-assembled monolayers · Murali Sastry · More Details Abstract Fulltext PDF.

  1. Microwave synthesis of electrode materials for lithium batteries

    Indian Academy of Sciences (India)

    A novel microwave method is described for the preparation of electrode materials required for lithium batteries. The method is simple, fast and carried out in most cases with the same starting material as in conventional methods. Good crystallinity has been noted and lower temperatures of reaction has been inferred in ...

  2. The influence of finite-length flaw effects on PTS analyses

    International Nuclear Information System (INIS)

    Keeney-Walker, J.; Dickson, T.L.

    1993-01-01

    Current licensing issues within the nuclear industry dictate a need to investigate the effects of cladding on the extension of small finite-length cracks near the inside surface of a vessel. Because flaws having depths of the order of the combined clad and heat affected zone thickness dominate the frequency distribution of flaws, their initiation probabilities can govern calculated vessel failure probabilities. Current pressurized-thermal-shock (PTS) analysis computer programs recognize the influence of the inner-surface cladding layer in the heat transfer and stress analysis models, but assume the cladding fracture toughness is the same as that for the base material. The programs do not recognize the influence cladding may have in inhibiting crack initiation and propagation of shallow finite-length surface flaws. Limited experimental data and analyses indicate the cladding can inhibit the propagation of certain shallow flaws. This paper describes an analytical study which was carried out to determine (1) the minimum flaw depth for crack initiation under PTS loading for semicircular surface flaws in a clad reactor pressure vessel and (2) the impact, in terms of the conditional probability of vessel failure, of using a semicircular surface flaw as the initial flaw and assuming that the flaw cannot propagate in the cladding. The analytical results indicate that for initiation a much deeper critical crack depth is required for the finite-length flaw than for the infinite-length flaw, except for the least severe transient. The minimum flaw depths required for crack initiation from the finite-length flaw analyses were incorporated into a modified version of the OCA-P code. The modified code was applied to the analysis of selected PTS transients, and the results produced a substantial decrease in the conditional probability of failure. This initial study indicates a significant effect on probabilistic fracture analyses by incorporating finite-length flaw results

  3. Determination of the coherence length in high-mobility semiconductor-coupled Josephson weak links

    International Nuclear Information System (INIS)

    Kleinsasser, A.W.

    1991-01-01

    A Nb-InAs-Nb superconductor-semiconductor-superconductor weak link based on a high-mobility homoepitaxial n-InAs film was reported recently [Akazaki, Kawakami, and Nittu J. Appl. Phys. 66, 6121 (1989)]. Measurements of the electron concentration, effective mass, and mobility allowed the coherence length in the normal link to be calculated. The mobility was high enough that the dirty limit was not applicable in the temperature range (∼2--7 K) over which the device critical current was measured. The temperature dependence of the critical current could not be fit by the usual theoretical form, even though an expression for the coherence length was used that should be applicable in both the clean and dirty limits. In this paper is demonstrated an excellent fit to the data, obtained by using the magnitude of the coherence length as a fitting parameter and assuming the dirty limit temperature dependence. This implies a coherence length proportional to T -1/2 but far shorter than that calculated from the known material parameters. It is suggested that a different scaling length may apply in high-mobility devices

  4. Nano-scaled graphene platelets with a high length-to-width aspect ratio

    Science.gov (United States)

    Zhamu, Aruna; Guo, Jiusheng; Jang, Bor Z.

    2010-09-07

    This invention provides a nano-scaled graphene platelet (NGP) having a thickness no greater than 100 nm and a length-to-width ratio no less than 3 (preferably greater than 10). The NGP with a high length-to-width ratio can be prepared by using a method comprising (a) intercalating a carbon fiber or graphite fiber with an intercalate to form an intercalated fiber; (b) exfoliating the intercalated fiber to obtain an exfoliated fiber comprising graphene sheets or flakes; and (c) separating the graphene sheets or flakes to obtain nano-scaled graphene platelets. The invention also provides a nanocomposite material comprising an NGP with a high length-to-width ratio. Such a nanocomposite can become electrically conductive with a small weight fraction of NGPs. Conductive composites are particularly useful for shielding of sensitive electronic equipment against electromagnetic interference (EMI) or radio frequency interference (RFI), and for electrostatic charge dissipation.

  5. Clinical Note Creation, Binning, and Artificial Intelligence

    OpenAIRE

    Deliberato, Rodrigo Oct?vio; Celi, Leo Anthony; Stone, David J

    2017-01-01

    The creation of medical notes in software applications poses an intrinsic problem in workflow as the technology inherently intervenes in the processes of collecting and assembling information, as well as the production of a data-driven note that meets both individual and healthcare system requirements. In addition, the note writing applications in currently available electronic health records (EHRs) do not function to support decision making to any substantial degree. We suggest that artifici...

  6. The algorithm of random length sequences synthesis for frame synchronization of digital television systems

    Directory of Open Access Journals (Sweden)

    Аndriy V. Sadchenko

    2015-12-01

    Full Text Available Digital television systems need to ensure that all digital signals processing operations are performed simultaneously and consistently. Frame synchronization dictated by the need to match phases of transmitter and receiver so that it would be possible to identify the start of a frame. As a frame synchronization signals are often used long length binary sequence with good aperiodic autocorrelation function. Aim: This work is dedicated to the development of the algorithm of random length sequences synthesis. Materials and Methods: The paper provides a comparative analysis of the known sequences, which can be used at present as synchronization ones, revealed their advantages and disadvantages. This work proposes the algorithm for the synthesis of binary synchronization sequences of random length with good autocorrelation properties based on noise generator with a uniform distribution law of probabilities. A "white noise" semiconductor generator is proposed to use as the initial material for the synthesis of binary sequences with desired properties. Results: The statistical analysis of the initial implementations of the "white noise" and synthesized sequences for frame synchronization of digital television is conducted. The comparative analysis of the synthesized sequences with known ones was carried out. The results show the benefits of obtained sequences in compare with known ones. The performed simulations confirm the obtained results. Conclusions: Thus, the search algorithm of binary synchronization sequences with desired autocorrelation properties received. According to this algorithm, the sequence can be longer in length and without length limitations. The received sync sequence can be used for frame synchronization in modern digital communication systems that will increase their efficiency and noise immunity.

  7. Observing professionals taking notes on screen

    NARCIS (Netherlands)

    Melenhorst, M.S.

    2005-01-01

    In this study 38 participants wrote a piece of advice based on reading and annotating information from an extensive Web site. Half of the participants took notes in a separate window, the other half used an advanced annotation tool. In text annotations were far more used than separate notes. The

  8. Cutting Whole Length or Partial Length of Internal Anal Sphincter in Managementof Fissure in Ano

    Directory of Open Access Journals (Sweden)

    Furat Shani Aoda

    2017-12-01

    Full Text Available A chronic anal fissure is a common painful perianal condition.The main operative procedure to treat this painful condition is a lateral internal sphincteretomy (LIS.The aim of study is to compare the outcome and complications of closed LIS up to the dentate line (whole length of internal sphincter or up to the fissure apex (partial length of internal sphincter in the treatment of anal fissure.It is a prospective comparativestudy including 100 patients with chronic fissure in ano. All patients assigned to undergo closed LIS. Those patients were randomly divided into two groups: 50 patients underwent LIS to the level of dentate line (whole length and other 50 patients underwent LIS to the level of fissure apex (partial length. Patients were followed up weekly in the 1st month, twice monthly in the second month then monthly   for next 2 months and finally after 1 year. There was satisfactory relief of pain in all patients in both groups & complete healing of the fissure occurred. Regarding post operative incontinence no major degree of incontinence occur in both group but minor degree of incontinence persists In 7 patients after whole length LIS after one year. In conclusion, both whole length & partial length LIS associated with improvement of pain, good chance of healing but whole length LIS associated with more chance of long term  flatus incontinence. Hence,we recommend partial length LIS as treatment forchronic anal fissure.

  9. Telomere length and depression

    DEFF Research Database (Denmark)

    Wium-Andersen, Marie Kim; Ørsted, David Dynnes; Rode, Line

    2017-01-01

    BACKGROUND: Depression has been cross-sectionally associated with short telomeres as a measure of biological age. However, the direction and nature of the association is currently unclear. AIMS: We examined whether short telomere length is associated with depression cross-sectionally as well...... as prospectively and genetically. METHOD: Telomere length and three polymorphisms, TERT, TERC and OBFC1, were measured in 67 306 individuals aged 20-100 years from the Danish general population and associated with register-based attendance at hospital for depression and purchase of antidepressant medication....... RESULTS: Attendance at hospital for depression was associated with short telomere length cross-sectionally, but not prospectively. Further, purchase of antidepressant medication was not associated with short telomere length cross-sectionally or prospectively. Mean follow-up was 7.6 years (range 0...

  10. Technical note on drainage systems

    DEFF Research Database (Denmark)

    Bentzen, Thomas Ruby

    This technical note will present simple but widely used methods for the design of drainage systems. The note will primarily deal with surface water (rainwater) which on a satisfactorily way should be transport into the drainage system. Traditional two types of sewer systems exist: A combined system......, where rainwater and sewage is transported in the same pipe, and a separate system where the two types of water are transported in individual pipe. This note will only focus on the separate rain/stormwater system, however, if domestic sewage should be included in the dimensioning procedure, it......’s not major different than described below - just remember to include this contribution for combined systems where the surface water (rain) and sewage are carried in the same pipes in the system and change some of the parameters for failure allowance (this will be elaborated further later on). The technical...

  11. Stalin and Marxism: a research note

    NARCIS (Netherlands)

    van Ree, E.

    1997-01-01

    This article concerns the research done by the author in Stalin‘s private library. The notes made in the works of Marx, Engels and Lenin suggest that until the end of his life Stalin felt himself in general agreement with these "classics." The choice of books and the notes support the thesis that,

  12. Is testing a more effective learning strategy than note-taking?

    Science.gov (United States)

    Rummer, Ralf; Schweppe, Judith; Gerst, Kathleen; Wagner, Simon

    2017-09-01

    The testing effect is both robust and generalizable. However, most of the underlying studies compare testing to a rather ineffective control condition: massed repeated reading. This article therefore compares testing with note-taking, which has been shown to be more effective than repeated reading. Experiment 1 is based on a 3 × 3 between-participants design with the factors learning condition (repeated reading vs. repeated testing vs. repeated note-taking) and final test delay (5 min vs. 1 week vs. 2 weeks). It shows that in the immediate condition, learning performance is best after note-taking. After 1 week, both the note-taking and the testing groups outperform the rereading group, and after 2 weeks, testing is superior to both note-taking and rereading. Since repeated notetaking may not be the most effective (and common) operationalization of note-taking, Experiment 2 contrasts repeated testing with 2 other note-taking conditions: note-taking plus note-reading and note-taking plus testing (with only a 2-week final test delay). Both conditions that include a testing phase result in better long-term learning than note-taking plus note-reading. In summary, our findings indicate that-in the long run-testing is a powerful learning tool both in isolation and in combination with note-taking. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  13. Non-linear optical materials

    CERN Document Server

    Saravanan, R

    2018-01-01

    Non-linear optical materials have widespread and promising applications, but the efforts to understand the local structure, electron density distribution and bonding is still lacking. The present work explores the structural details, the electron density distribution and the local bond length distribution of some non-linear optical materials. It also gives estimation of the optical band gap, the particle size, crystallite size, and the elemental composition from UV-Visible analysis, SEM, XRD and EDS of some non-linear optical materials respectively.

  14. EVALUATION OF STUDENT'S NOTES IN A BLENDED LEARNING COURSE

    OpenAIRE

    Minoru Nakayama; Kouichi Mutsuura; Hiroh Yamamoto

    2011-01-01

    Student’s notes are evaluated to trace their learning process in a blended learning course, and the factors affecting the quality of these notes are discussed. As individual note-taking performance may be based on student’s characteristics, these contributions are also examined. Some factors about per-sonality and the learning experience are sig-nificant, and positively affect the grades given to notes. Lexical features of notes tak-en were extracted using a text analysis tech-nique, and ...

  15. Influence of the length of institutionalization on older adults' postural balance and risk of falls: a transversal study.

    Science.gov (United States)

    Batista, Wagner Oliveira; Alves Junior, Edmundo de Drummond; Porto, Flávia; Pereira, Fabio Dutra; Santana, Rosimere Ferreira; Gurgel, Jonas Lírio

    2014-01-01

    to ascertain the influence of the length of institutionalization on older adults' balance and risk of falls. to evaluate the risk of falls, the Berg Balance Scale and the Timed Get Up and Go test were used; and for measuring postural balance, static stabilometry was used, with acquisition of the elliptical area of 95% and mean velocities on the x and y axes of center of pressure displacement. Parametric and nonparametric measures of association and comparison (αstudy's results point to the difficulty of undertaking postural control tasks, showing a leveling below the clinical tests' reference scores. In the stabilometric behavior, one should note the reduction of the parameters as the length of institutionalization increases, contradicting the assumptions. This study's results offer support for the development of a multi-professional model for intervention with the postural control and balance of older adults living in homes for the aged.

  16. [Natural Orifice Transluminal Endoscopic Surgery (NOTES)].

    Science.gov (United States)

    Kim, Yong Sik; Kim, Chul Young; Chun, Hoon Jai

    2008-03-01

    Recently, the field of gastrointestinal endoscopy is developing rapidly. Once limited to the gastroinstestinal lumen, the endoscopic technology is now breaking the barriers and extending its boundary to peritoneal and pleural space. In 2004, Dr. Kalloo, a gastroenterologist, observed intraperitoneal organs of a pig using a conventional endoscope through the stomach wall. Since then, new endoscopic technique of intraperitoneal intervention with transluminal approach named the Natural Orifice Transluminal Endoscopic Surgery or NOTES has been introduced. NOTES reaches the target organ by inserting the endoscope through a natural orifice (e.g. mouth, anus, vagina, urethra) and entering the peritoneal lumen by means of making an incision on the luminal wall. After a series of successful experiences in animal studies, NOTES are now being tried on human subjects. There are still many obstacles to overcome, but bright future for this new technology is expected because of its proposed advantages of less pain, lower complication rate, short recovery time, and scarless access. In this review, we plan to learn about NOTES.

  17. In-plane Material Filters for the Discrete Material Optimization Method

    DEFF Research Database (Denmark)

    Sørensen, Rene; Lund, Erik

    2015-01-01

    , because the projection filter is a non-linear function of the design variables, the projected variables have to be re-scaled in a final so-called normalization filter. This is done to prevent the optimizer in creating superior, but non-physical pseudo-materials. The method is demonstrated on a series......This paper presents in-plane material filters for the Discrete Material Optimization method used for optimizing laminated composite structures. The filters make it possible for engineers to specify a minimum length scale which governs the minimum size of areas with constant material continuity....... Consequently, engineers can target the available production methods, and thereby increase its manufacturability while the optimizer is free to determine which material to apply together with an optimum location, shape, and size of these areas with constant material continuity. By doing so, engineers no longer...

  18. Electromagnetic Processing of Materials Materials Processing by Using Electric and Magnetic Functions

    CERN Document Server

    Asai, Shigeo

    2012-01-01

    This book is both a course book and a monograph. In fact, it has developed from notes given to graduate course students on materials processing in the years 1989 to 2006. Electromagnetic Processing of Materials (EPM), originates from a branch of materials science and engineering developed in the 1980s as a field aiming to create new materials and/or design processes by making use of various functions which appear when applying the electric and magnetic fields to materials. It is based on transport phenomena, materials processing and magnetohydrodynamics. The first chapter briefly introduces the history, background and technology of EPM. In the second chapter, the concept of transport phenomena is concisely introduced and in the third chapter the essential part of magnetohydrodynamics is transcribed and readers are shown that the concept of transport phenomena does not only apply to heat, mass and momentum, but also magnetic field. The fourth chapter describes electromagnetic processing of electrica...

  19. Evaluating the impact of patients' online access to doctors' visit notes: designing and executing the OpenNotes project

    Directory of Open Access Journals (Sweden)

    Leveille Suzanne G

    2012-04-01

    Full Text Available Abstract Background Providers and policymakers are pursuing strategies to increase patient engagement in health care. Increasingly, online sections of medical records are viewable by patients though seldom are clinicians' visit notes included. We designed a one-year multi-site trial of online patient accessible office visit notes, OpenNotes. We hypothesized that patients and primary care physicians (PCPs would want it to continue and that OpenNotes would not lead to significant disruptions to doctors' practices. Methods/Design Using a mixed methods approach, we designed a quasi-experimental study in 3 diverse healthcare systems in Boston, Pennsylvania, and Seattle. Two sites had existing patient internet portals; the third used an experimental portal. We targeted 3 key areas where we hypothesized the greatest impacts: beliefs and attitudes about OpenNotes, use of the patient internet portals, and patient-doctor communication. PCPs in the 3 sites were invited to participate in the intervention. Patients who were registered portal users of participating PCPs were given access to their PCPs' visit notes for one year. PCPs who declined participation in the intervention and their patients served as the comparison groups for the study. We applied the RE-AIM framework to our design in order to capture as comprehensive a picture as possible of the impact of OpenNotes. We developed pre- and post-intervention surveys for online administration addressing attitudes and experiences based on interviews and focus groups with patients and doctors. In addition, we tracked use of the internet portals before and during the intervention. Results PCP participation varied from 19% to 87% across the 3 sites; a total of 114 PCPs enrolled in the intervention with their 22,000 patients who were registered portal users. Approximately 40% of intervention and non-intervention patients at the 3 sites responded to the online survey, yielding a total of approximately 38

  20. Deaf/hard-of-hearing and other postsecondary learners' retention of STEM content with tablet computer-based notes.

    Science.gov (United States)

    Stinson, Michael S; Elliot, Lisa B; Easton, Donna

    2014-04-01

    Four groups of postsecondary students, 25 who were deaf/hard of hearing (D/HH), 25 with a learning disability, 25 who were English language learners (ELLs), and 25 without an identified disability studied notes that included text and graphical information based on a physics or a marine biology lecture. The latter 3 groups were normally hearing. All groups had higher scores on post- than on pretests for each lecture, with each group showing generally similar gains in amount of material learned from the pretest to the posttest. For each lecture, the D/HH students scored lower on the pre- and posttests than the other 3 groups of participants. Results indicated that students acquired measurable amounts of information from studying these types of notes for relatively short periods and that the notes have equal potential to support the acquisition of information by each of these groups of students.

  1. ITER - Progress in design and validating R and D. Note by the Director. ITER meeting, Moscow, 28 June 2000

    International Nuclear Information System (INIS)

    2001-01-01

    This note summarises, for the ITER Council, material presented in detail to TAC, in the report ''Progress in Resolving Open Design Issues from the ODR'', including: further investigation of physics issues raised in the TAC report or in the course of the Parties' domestic assessments; and features of the ITER design which reflect a resolution of choice of options. In addition, the note summarises and illustrates recent progress in the programme of validating technology R and D, as presented in the report to TAC, ''ITER Technology R and D Progress Report''

  2. The transvaginal hybrid NOTES versus conventionally assisted laparoscopic sigmoid resection for diverticular disease (TRANSVERSAL) trial: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Senft, Jonas D; Warschkow, Rene; Diener, Markus K; Tarantino, Ignazio; Steinemann, Daniel C; Lamm, Sebastian; Simon, Thomas; Zerz, Andreas; Müller-Stich, Beat P; Linke, Georg R

    2014-11-20

    Natural orifice transluminal endoscopic surgery (NOTES) is the consequence of further development of minimally invasive surgery to reduce abdominal incisions and surgical trauma. The potential benefits are expected to be less postoperative pain, faster convalescence, and reduced risk for incisional hernias and wound infections compared to conventional methods. Recent clinical studies have demonstrated the feasibility and safety of transvaginal NOTES, and transvaginal access is currently the most frequent clinically applied route for NOTES procedures. However, despite increasing clinical application, no firm clinical evidence is available for objective assessment of the potential benefits and risks of transvaginal NOTES compared to the current surgical standard. The TRANSVERSAL trial is designed as a randomized controlled trial to compare transvaginal hybrid NOTES and laparoscopic-assisted sigmoid resection. Female patients referred to elective sigmoid resection due to complicated or reoccurring diverticulitis of the sigmoid colon are considered eligible. The primary endpoint will be pain intensity during mobilization 24 hours postoperatively as measured by the blinded patient and blinded assessor on a visual analogue scale (VAS). Secondary outcomes include daily pain intensity and analgesic use, patient mobility, intraoperative complications, morbidity, length of stay, quality of life, and sexual function. Follow-up visits are scheduled 3, 12, and 36 months after surgery. A total sample size of 58 patients was determined for the analysis of the primary endpoint. The confirmatory analysis will be performed based on the intention-to-treat (ITT) principle. The TRANSVERSAL trial is the first study to compare transvaginal hybrid NOTES and conventionally assisted laparoscopic surgery for colonic resection in a randomized controlled setting. The results of the TRANSVERSAL trial will allow objective assessment of the potential benefits and risks of NOTES compared to the

  3. Note-taking in the employment interview: effects on recall and judgments.

    Science.gov (United States)

    Middendorf, Catherine Houdek; Macan, Therese Hoff

    2002-04-01

    Although note-taking in the employment interview is highly recommended, little research has examined its effects. This study investigated the effects of note-taking styles, review of the notes, and content of the notes on participants' cued recall of information and decisions made from videotaped employment interviews. Note-taking increased recall accuracy but not judgment accuracy. Being able to review notes resulted in increased judgment accuracy for those taking conventional-style notes. The content of the notes also had important implications for conventional note-takers, suggesting some benefits of recording notes using the key-points style. The findings suggest that the act of note-taking may be more important for memory and legal reasons than for improving the decisions made by interviewers.

  4. A qualitative examination of inappropriate hospital admissions and lengths of stay

    Directory of Open Access Journals (Sweden)

    Hammond Christina L

    2009-03-01

    Full Text Available Abstract Background Research has shown that a number of patients, with a variety of diagnoses, are admitted to hospital when it is not essential and can remain in hospital unnecessarily. To date, research in this area has been primarily quantitative. The purpose of this study was to explore the perceived causes of inappropriate or prolonged lengths of stay and focuses on a specific population (i.e., patients with long term neurological conditions. We also wanted to identify interventions which might avoid admission or expedite discharge as periods of hospitalisation pose particular risks for this group. Methods Two focus groups were conducted with a convenience sample of eight primary and secondary care clinicians working in the Derbyshire area. Data were analysed using a thematic content approach. Results The participants identified a number of key causes of inappropriate admissions and lengths of stay, including: the limited capacity of health and social care resources; poor communication between primary and secondary care clinicians and the cautiousness of clinicians who manage patients in community settings. The participants also suggested a number of strategies that may prevent inappropriate admissions or reduce length of stay (LoS, including: the introduction of new sub-acute care facilities; the introduction of auxiliary nurses to support specialist nursing staff and patient held summaries of specialist consultations. Conclusion Clinicians in both the secondary and primary care sectors acknowledged that some admissions were unnecessary and some patients remain in hospital for a prolonged period. These events were attributed to problems with the current capacity or structuring of services. It was noted, for example, that there is a shortage of appropriate therapeutic services and that the distribution of beds between community and sub-acute care should be reviewed.

  5. Particle localization and hyperuniformity of polymer-grafted nanoparticle materials

    Energy Technology Data Exchange (ETDEWEB)

    Chremos, Alexandros [Materials Science and Engineering Division, National Institute of Standards and Technology, Gaithersburg, MD (United States); Douglas, Jack F.

    2017-05-15

    The properties of materials largely reflect the degree and character of the localization of the molecules comprising them so that the study and characterization of particle localization has central significance in both fundamental science and material design. Soft materials are often comprised of deformable molecules and many of their unique properties derive from the distinct nature of particle localization. We study localization in a model material composed of soft particles, hard nanoparticles with grafted layers of polymers, where the molecular characteristics of the grafted layers allow us to ''tune'' the softness of their interactions. Soft particles are particular interesting because spatial localization can occur such that density fluctuations on large length scales are suppressed, while the material is disordered at intermediate length scales; such materials are called ''disordered hyperuniform''. We use molecular dynamics simulation to study a liquid composed of polymer-grafted nanoparticles (GNP), which exhibit a reversible self-assembly into dynamic polymeric GNP structures below a temperature threshold, suggesting a liquid-gel transition. We calculate a number of spatial and temporal correlations and we find a significant suppression of density fluctuations upon cooling at large length scales, making these materials promising for the practical fabrication of ''hyperuniform'' materials. (copyright 2017 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  6. Hybrid and hierarchical composite materials

    CERN Document Server

    Kim, Chang-Soo; Sano, Tomoko

    2015-01-01

    This book addresses a broad spectrum of areas in both hybrid materials and hierarchical composites, including recent development of processing technologies, structural designs, modern computer simulation techniques, and the relationships between the processing-structure-property-performance. Each topic is introduced at length with numerous  and detailed examples and over 150 illustrations.   In addition, the authors present a method of categorizing these materials, so that representative examples of all material classes are discussed.

  7. Effect of repetitive pecking at working length for glide path preparation using G-file

    Directory of Open Access Journals (Sweden)

    Jung-Hong Ha

    2015-05-01

    Full Text Available Objectives Glide path preparation is recommended to reduce torsional failure of nickel-titanium (NiTi rotary instruments and to prevent root canal transportation. This study evaluated whether the repetitive insertions of G-files to the working length maintain the apical size as well as provide sufficient lumen as a glide path for subsequent instrumentation. Materials and Methods The G-file system (Micro-Mega composed of G1 and G2 files for glide path preparation was used with the J-shaped, simulated resin canals. After inserting a G1 file twice, a G2 file was inserted to the working length 1, 4, 7, or 10 times for four each experimental group, respectively (n = 10. Then the canals were cleaned by copious irrigation, and lubricated with a separating gel medium. Canal replicas were made using silicone impression material, and the diameter of the replicas was measured at working length (D0 and 1 mm level (D1 under a scanning electron microscope. Data was analysed by one-way ANOVA and post-hoc tests (p = 0.05. Results The diameter at D0 level did not show any significant difference between the 1, 2, 4, and 10 times of repetitive pecking insertions of G2 files at working length. However, 10 times of pecking motion with G2 file resulted in significantly larger canal diameter at D1 (p < 0.05. Conclusions Under the limitations of this study, the repetitive insertion of a G2 file up to 10 times at working length created an adequate lumen for subsequent apical shaping with other rotary files bigger than International Organization for Standardization (ISO size 20, without apical transportation at D0 level.

  8. Dealing with imperfection: quantifying potential length scale artefacts from nominally spherical indenter probes

    International Nuclear Information System (INIS)

    Constantinides, G; Silva, E C C M; Blackman, G S; Vliet, K J Van

    2007-01-01

    Instrumented nanoindenters are commonly employed to extract elastic, plastic or time-dependent mechanical properties of the indented material surface. In several important cases, accurate determination of the indenter probe radii is essential for the proper analytical interpretation of the experimental response, and it cannot be circumvented by an experimentally determined expression for the contact area as a function of depth. Current approaches quantify the indenter probe radii via inference from a series of indents on a material with known elastic modulus (e.g., fused quartz) or through the fitting of two-dimensional projected images acquired via atomic force microscopy (AFM) or scanning electron microscopy (SEM) images. Here, we propose a more robust methodology, based on concepts of differential geometry, for the accurate determination of three-dimensional indenter probe geometry. The methodology is presented and demonstrated for four conospherical indenters with probe radii of the order of 1-10 μm. The deviation of extracted radii with manufacturer specifications is emphasized and the limits of spherical approximations are presented. All four probes deviate from the assumed spherical geometry, such that the effective radii are not independent of distance from the probe apex. Significant errors in interpretation of material behaviour will result if this deviation is unaccounted for during the analysis of indentation load-depth responses obtained from material surfaces of interest, including observation of an artificial length scale that could be misinterpreted as an effect attributable to material length scales less than tens of nanometres in size or extent

  9. 19 CFR 10.461 - Retail packaging materials and containers.

    Science.gov (United States)

    2010-04-01

    ... Free Trade Agreement Rules of Origin § 10.461 Retail packaging materials and containers. Packaging... classification set out in General Note 26(n), HTSUS. If the good is subject to a regional value content... non-originating materials, as the case may be, in calculating the regional value content of the good...

  10. Gaz de France. Operation note

    International Nuclear Information System (INIS)

    2003-01-01

    This note was published for the public at the occasion of the admission to Euronext's Eurolist of the existing shares that make the capital of Gaz de France company, the French gas utility. The note gives some informations about Gaz de France activity, and about its strategy of development in the European gas market. Then it describes the offer relative to the opening of Gaz de France capital. Some selected financial data and some precision about the risk factors and the management of the company complete the document. (J.S.)

  11. Anthropometric measurements of foot length and shape in children 2 to 7 years of age

    OpenAIRE

    Vrdoljak, Ozren; Kujundžić Tiljak, Mirjana; Čimić, Mislav

    2017-01-01

    Background and purpose: A child’s foot changes shape and proportions during growth so that it adapts to function. The purpose of this article is to determine foot length in children aged 2-7 years as a fundamental unit for measuring the growth of the foot, with which it will be able to compare other anthropometric measures of the foot. Determination of the shape of the foot and interpretation of the growth curve of the foot in length are important for standardization of the foot.Materials and...

  12. Kidney Length in Normal Korean Children

    International Nuclear Information System (INIS)

    Kim, In One; Cheon, Jung Eun; Lee, Young Seok; Lee, Sun Wha; Kim, Ok Hwa; Kim, Ji Hye; Kim, Hong Dae; Sim, Jung Suk

    2010-01-01

    Renal length offers important information to detect or follow-up various renal diseases. The purpose of this study was to determine the kidney length of normal Korean children in relation to age, height, weight, body surface area (BSA), and body mass index (BMI). Children between 1 month and 15 years of age without urological abnormality were recruited. Children below 3rd percentile and over 97th percentile for height or weight were excluded. Both renal lengths were measured in the prone position three times and then averaged by experienced radiologists. The mean length and standard deviation for each age group was obtained, and regression equation was calculated between renal length and age, weight, height, BSA, and BMI, respectively. Renal length was measured in 550 children. Renal length grows rapidly until 24 month, while the growth rate is reduced thereafter. The regression equation for age is: renal length (mm) = 45.953 + 1.064 x age (month, ≤ 24 months) (R2 = 0.720) or 62.173 + 0.203 x age (months, > 24 months) (R2 = 0.711). The regression equation for height is: renal length (mm) = 24.494 + 0.457 x height (cm) (R2 = 0.894). The regression equation for weight is: renal length (mm) = 38.342 + 2.117 x weight (kg, ≤18 kg) (R2 = 0.852) or 64.498 + 0.646 x weight (kg, > 18 kg) (R2 = 0.651). The regression equation for BSA is: renal length (mm) = 31.622 + 61.363 x BSA (m2, ≤ 0.7) (R2 = 0.857) or 52.717 + 29.959 x BSA (m2, > 0.7) (R2 = 0.715). The regression equation for BMI is: renal length (mm) = 44.474 + 1.163 x BMI (R2 = 0.079). This study provides data on the normal renal length and its association with age, weight, height, BSA and BMI. The results of this study will guide the detection and follow-up of renal diseases in Korean children

  13. Microwave-Assisted Synthesis of Nano-materials in Aqueous

    Science.gov (United States)

    Whether it is termed a revolution or simply a continuous evolution, clearly development of new materials and their understanding on smaller and smaller length scale is at the root of progress in many areas of materials science.1 This is true in developing existing bulk materials...

  14. Assessment of microbial contamination and oral health risks associated with handling of Indian currency notes circulating in Bengaluru city: A cross-sectional survey

    Directory of Open Access Journals (Sweden)

    D P Narayan

    2015-01-01

    Full Text Available Introduction: Accumulated data obtained over the last 20 years on the microbial status and survival of pathogens on currency notes indicate that this could represent a potential cause of sporadic cases of food borne illness. Objectives: To identify the micro-organisms present on the Indian currency notes and the oral health risks due to microbial contamination of Indian currency notes circulating in Bengaluru city. Materials and Methods: A cross-sectional survey was conducted and the Indian currency notes of various denominations (Rs. 10, Rs. 20, Rs. 50, Rs. 100, Rs. 500, and Rs. 1000 were collected from fruit vendors, hawkers, vegetable vendors, bus conductors, railway ticket counters, hotel counters, and butchers. Sample size was determined to be 70 Indian currency notes. Convenience sampling technique was used. Microbiological analysis of the collected currency notes was done. Results: The contamination rate of collected currency notes from the butchers and hawkers were 80% and 60% respectively. Staphylococcus aureus was present on 15 currency notes (21.42% and was found to be higher in Rs. 10 than in other currency denominations. Streptococcus pyogenes was present on four currency notes (5.714% of Rs. 10. Conclusion: The Indian currency notes circulating in Bengaluru city were contaminated with pathogenic bacteria. The oral health risks due to microbial contamination of Indian currency notes are acute pharyngitis, peritonsillar or retropharyngeal abscess, mastoiditis, sinusitis, otitis media, mild cellulitis, angular cheilitis, some endodontic infections, osteomyelitis of the jaw, parotitis, and oral mucositis.

  15. Notes on constraints for the observation of Polar Kerr Effect in complex materials

    International Nuclear Information System (INIS)

    Kapitulnik, Aharon

    2015-01-01

    While Kerr effect has been used extensively for the study of magnetic materials, it is only recently that its has shown to be a powerful tool for the study of more complex quantum matter. Since such materials tend to exhibit a wealth of new phases and broken symmetries, it is important to understand the general constraints on the possibility of observing a finite Kerr effect. In this paper we reviewed the consequences of reciprocity on the scattering of electromagnetic waves. In particular we concentrate on the possible detection of Kerr effect from chiral media with and without time-reversal symmetry breaking. We show that a finite Kerr effect is possible only if reciprocity is broken. Introducing the utilization of the Sagnac interferometer as a detector for breakdown of reciprocity via the detection of a finite Kerr effect, we argue that in the linear regime, a finite detection is possible only if reciprocity is broken. We then discuss possible Kerr effect detection for materials with natural optical activity, magnetism, and chiral superconductivity

  16. Notes on constraints for the observation of Polar Kerr Effect in complex materials

    Energy Technology Data Exchange (ETDEWEB)

    Kapitulnik, Aharon, E-mail: aharonk@stanford.edu [Department of Applied Physics, Stanford University, Stanford, CA 94305 (United States); Department of Physics, Stanford University, Stanford, CA 94305 (United States); Stanford Institute for Materials and Energy Sciences, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States)

    2015-03-01

    While Kerr effect has been used extensively for the study of magnetic materials, it is only recently that its has shown to be a powerful tool for the study of more complex quantum matter. Since such materials tend to exhibit a wealth of new phases and broken symmetries, it is important to understand the general constraints on the possibility of observing a finite Kerr effect. In this paper we reviewed the consequences of reciprocity on the scattering of electromagnetic waves. In particular we concentrate on the possible detection of Kerr effect from chiral media with and without time-reversal symmetry breaking. We show that a finite Kerr effect is possible only if reciprocity is broken. Introducing the utilization of the Sagnac interferometer as a detector for breakdown of reciprocity via the detection of a finite Kerr effect, we argue that in the linear regime, a finite detection is possible only if reciprocity is broken. We then discuss possible Kerr effect detection for materials with natural optical activity, magnetism, and chiral superconductivity.

  17. Optimization of path length stretching in Monte Carlo calculations for non-leakage problems

    Energy Technology Data Exchange (ETDEWEB)

    Hoogenboom, J.E. [Delft Univ. of Technology (Netherlands)

    2005-07-01

    Path length stretching (or exponential biasing) is a well known variance reduction technique in Monte Carlo calculations. It can especially be useful in shielding problems where particles have to penetrate a lot of material before being tallied. Several authors sought for optimization of the path length stretching parameter for detection of the leakage of neutrons from a slab. Here the adjoint function behaves as a single exponential function and can well be used to determine the stretching parameter. In this paper optimization is sought for a detector embedded in the system, which changes the adjoint function in the detector drastically. From literature it is known that the combination of path length stretching and angular biasing can result in appreciable variance reduction. However, angular biasing is not generally available in general purpose Monte Carlo codes and therefore we want to restrict ourselves to the application of pure path length stretching and finding optimum parameters for that. Nonetheless, the starting point for our research is the zero-variance scheme. In order to study the solution in detail the simplified monoenergetic two-direction model is adopted, which allows analytical solutions and can still be used in a Monte Carlo simulation. Knowing the zero-variance solution analytically, it is shown how optimum path length stretching parameters can be derived from it. It results in path length shrinking in the detector. Results for the variance in the detector response are shown in comparison with other patterns for the stretching parameter. The effect of anisotropic scattering on the path length stretching parameter is taken into account. (author)

  18. The Effect of CFRP Length on the Failure Mode of Strengthened Concrete Beams

    Directory of Open Access Journals (Sweden)

    Jun Ding

    2014-06-01

    Full Text Available This paper reports the effects of carbon fiber-reinforced polymer (CFRP length on the failure process, pattern and crack propagation for a strengthened concrete beam with an initial notch. The experiments measuring load-bearing capacity for concrete beams with various CFRP lengths have been performed, wherein the crack opening displacements (COD at the initial notch are also measured. The application of CFRP can significantly improve the load-bearing capacity, and the failure modes seem different with various CFRP lengths. The stress profiles in the concrete material around the crack tip, at the end of CFRP and at the interface between the concrete and CFRP are then calculated using the finite element method. The experiment measurements are validated by theoretical derivation and also support the finite element analysis. The results show that CFRP can significantly increase the ultimate load of the beam, while such an increase stops as the length reaches 0.15 m. It is also concluded that the CFRP length can influence the stress distribution at three critical stress regions for strengthened concrete beams. However, the optimum CFRP lengths vary with different critical stress regions. For the region around the crack tip, it is 0.15 m; for the region at the interface it is 0.25 m, and for the region at the end of CFRP, it is 0.30 m. In conclusion, the optimum CFRP length in this work is 0.30 m, at which CFRP strengthening is fully functioning, which thus provides a good reference for the retrofitting of buildings.

  19. Density functional theory and multiscale materials modeling

    Indian Academy of Sciences (India)

    One of the vital ingredients in the theoretical tools useful in materials modeling at all the length scales of interest is the concept of density. In the microscopic length scale, it is the electron density that has played a major role in providing a deeper understanding of chemical binding in atoms, molecules and solids.

  20. Characterization of porous materials by small-angle scattering

    Indian Academy of Sciences (India)

    With the availability of ultra small-angle scattering instruments, one can investigate porous materials in the sub-micron length scale. Because of the increased accessible length scale vis-a-vis the multiple scattering effect, conventional data analysis procedures based on single scattering approximation quite often fail.

  1. Bulletin of Materials Science | News

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science; Volume 23; Issue 3. Issue front cover thumbnail. Volume 23, Issue 3. June 2000, pages 159-238. pp 159-163 Nanomaterials. A note on the use of ellipsometry for studying the kinetics of formation of self-assembled monolayers · Murali Sastry · More Details Abstract Fulltext PDF.

  2. State switching kinetics for quasi-one-dimensional nanosystems: Effects of Finite length and irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Petukhov, B. V., E-mail: petukhov@ns.crys.ras.ru [Russian Academy of Sciences, Shubnikov Institute of Crystallography, Federal Scientific Research Centre “Crystallography and Photonics,” (Russian Federation)

    2017-01-15

    The state switching in an extended quasi-one-dimensional material is modeled by the stochastic formation of local new-state nuclei and their subsequent growth along the system axis. An analytical approach is developed to describe the influence of defects, dividing a sample into an ensemble of finite-length segments, on its state switching kinetics. As applied to magnetic systems, the method makes it possible to calculate magnetization curves for different defect concentrations and parameters of material.

  3. The comparison between the length of vertical dimension of occlusion and the length of thumb on undergraduate Mongoloid students

    Directory of Open Access Journals (Sweden)

    Goh Li Teng

    2011-03-01

    Full Text Available The Thumb Rule of Leonardo da Vinci states that many proportions of the face show relationship with the length of thumb which is measured from the proximal tip of the proximal phalanx to the distal tip of the distal phalanx. Previous studies have shown that the length of the vertical dimension of occlusion (VDO is similar to the length of thumb of the Caucasoid race. The purpose of this study is to determine whether the length of VDO have correlations with the length of thumb among those of the Mongoloid race. This study took a survey method with the analytical cross-sectional approach. A total of 80 students of Faculty of Dentistry who have fulfilled all population criteria were randomly chosen to measure the length of VDO and the length of the thumb. Results analyzed with Student's t-test statistic revealed that there was a significant difference between males and females in the length of VDO and the length of the thumb, however, there was no significant difference between the length of VDO and the length of the thumb. There were very strong correlations (P<0.05 between the length of VDO and the length of the thumb. As a conclusion, the length of thumb can be suggested as an objective method to determine the length of VDO in this population.

  4. Intentional forgetting: note-taking as a naturalistic example.

    Science.gov (United States)

    Eskritt, Michelle; Ma, Sierra

    2014-02-01

    In the present study, we examined whether note-taking as a memory aid may provide a naturalistic example of intentional forgetting. In the first experiment, participants played Concentration, a memory card game in which the identity and location of pairs of cards need to be remembered. Before the game started, half of the participants were allowed to study the cards, and the other half made notes that were then unexpectedly taken away. No significant differences emerged between the two groups for remembering identity information, but the study group remembered significantly more location information than did the note-taking group. In a second experiment, we examined whether note-takers would show signs of proactive interference while playing Concentration repeatedly. The results indicated that they did not. The findings suggest that participants adopted an intentional-forgetting strategy when using notes to store certain types of information.

  5. Full-length high-temperature severe fuel damage test No. 2

    International Nuclear Information System (INIS)

    Hesson, G.M.; Lombardo, N.J.; Pilger, J.P.; Rausch, W.N.; King, L.L.; Hurley, D.E.; Parchen, L.J.; Panisko, F.E.

    1993-09-01

    Hazardous conditions associated with performing the Full-Length High- Temperature (FLHT). Severe Fuel Damage Test No. 2 experiment have been analyzed. Major hazards that could cause harm or damage are (1) radioactive fission products, (2) radiation fields, (3) reactivity changes, (4) hydrogen generation, (5) materials at high temperature, (6) steam explosion, and (7) steam pressure pulse. As a result of this analysis, it is concluded that with proper precautions the FLHT- 2 test can be safely conducted

  6. Ethnomathematics study: uncovering units of length, area, and volume in Kampung Naga Society

    Science.gov (United States)

    Septianawati, T.; Turmudi; Puspita, E.

    2017-02-01

    During this time, mathematics is considered as something neutral and not associated with culture. It can be seen from mathematics learning in the school which adopt many of foreign mathematics learning are considered more advanced (western). In fact, Indonesia is a rich country in cultural diversity. In the cultural activities, there are mathematical ideas that were considered a important thing in the mathematics learning. A study that examines the idea or mathematical practices in a variety of cultural activities are known as ethnomathematics. In Indonesia, there are some ethnic maintain their ancestral traditions, one of them is Kampung Naga. Therefore, this study was conducted in Kampung Naga. This study aims to uncover units of length, area, and volume used by Kampung Naga society. This study used a qualitative approach and ethnography methods. In this research, data collection is done through the principles of ethnography such as observation, interviews, documentation, and field notes. The results of this study are units of length, area, and volume used by Kampung Naga society and its conversion into standard units. This research is expected to give information to the public that mathematics has a relationship with culture and become recommendation to mathematics curriculum in Indonesia.

  7. Convergence of macroscopic tongue anatomy in ruminants and scaling relationships with body mass or tongue length.

    Science.gov (United States)

    Meier, Andrea R; Schmuck, Ute; Meloro, Carlo; Clauss, Marcus; Hofmann, Reinhold R

    2016-03-01

    Various morphological measures demonstrate convergent evolution in ruminants with their natural diet, in particular with respect to the browser/grazer dichotomy. Here, we report quantitative macroanatomical measures of the tongue (length and width of specific parts) of 65 ruminant species and relate them to either body mass (BM) or total tongue length, and to the percentage of grass in the natural diet (%grass). Models without and with accounting for the phylogenetic structures of the dataset were used, and models were ranked using Akaike's Information Criterion. Scaling relationships followed geometric principles, that is, length measures scaled with BM to the power of 0.33. Models that used tongue length rather than BM as a body size proxy were consistently ranked better, indicating that using size proxies that are less susceptible to a wider variety of factors (such as BM that fluctuates with body condition) should be attempted whenever possible. The proportion of the freely mobile tongue tip of the total tongue (and hence also the corpus length) was negatively correlated to %grass, in accordance with concepts that the feeding mechanism of browsers requires more mobile tongues. It should be noted that some nonbrowsers, such as cattle, use a peculiar mechanism for grazing that also requires long, mobile tongues, but they appear to be exceptions. A larger corpus width with increasing %grass corresponds to differences in snout shape with broader snouts in grazers. The Torus linguae is longer with increasing %grass, a finding that still warrants functional interpretation. This study shows that tongue measures covary with diet in ruminants. In contrast, the shape of the tongue (straight or "hourglass-shaped" as measured by the ratio of the widest and smallest corpus width) is unrelated to diet and is influenced strongly by phylogeny. © 2015 Wiley Periodicals, Inc.

  8. Choosing a proper working length can improve the lifespan of locked plates. A biomechanical study.

    Science.gov (United States)

    Hoffmeier, Konrad L; Hofmann, Gunther O; Mückley, Thomas

    2011-05-01

    It is hypothesized that the working length influences the implants fatigue behavior. However, few studies addressing this issue came to contrary results. Therefore, we tested systematically the influence of working length and implant material on the plate's endurance. We used an artificial model providing the substantial angle and length conditions of a human femur. A fracture gap of 10mm was bridged with identical shaped plate implants made of stainless steel and grade-2 titanium. The fatigue strength was tested for a short, medium and long working length. Aiming at an implant failure within 80,000 loading cycles the upper load threshold was set to 265N for the titanium plates and to 420N for the steel plates. The lower load threshold was -20N for both plates. For the steel plates there was no correlation between fatigue strength and working length. The construct stiffness did not differ at short and medium working length and was reduced by 10% (P=0.047) at long working length. For the titanium plates the fatigue strength tends to increase with the working length but this correlation was not significant (τ=0.417, P=0.051). Further there was a negative correlation between working length and construct stiffness (τ=0.552; P=0.01). The working length has no appreciable effect on the endurance of the steel plates. Compared to the grade 2-titanium plates the stainless steel plates sustain a larger amount of cyclic load. However, for the titanium plates a larger working length tends to improve the endurance. Copyright © 2010 Elsevier Ltd. All rights reserved.

  9. Flame Length

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — Flame length was modeled using FlamMap, an interagency fire behavior mapping and analysis program that computes potential fire behavior characteristics. The tool...

  10. Application note :

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Thomas V.

    2013-08-01

    The development of the XyceTM Parallel Electronic Simulator has focused entirely on the creation of a fast, scalable simulation tool, and has not included any schematic capture or data visualization tools. This application note will describe how to use the open source schematic capture tool gschem and its associated netlist creation tool gnetlist to create basic circuit designs for Xyce, and how to access advanced features of Xyce that are not directly supported by either gschem or gnetlist.

  11. Lagos Notes and Records

    African Journals Online (AJOL)

    PROMOTING ACCESS TO AFRICAN RESEARCH ... Lagos Notes and Records is an annual, interdisciplinary journal of the humanities. ... Insuring the Nation: Europeans and the Emergence of Modern Insurance Business in Colonial Nigeria ...

  12. Interpreters' notes. On the choice of language

    DEFF Research Database (Denmark)

    Dam, Helle Vrønning

    2004-01-01

    This paper reports on a small-scale empirical study on note-taking in consecutive interpreting. As data, the study draws on the notes produced by four subjects while interpreting one Spanish source text consecutively into Danish, on the one hand, and one Danish source text into Spanish...... to particular scrutiny here. However, somewhat surprisingly, the results of the analyses indicate that the choice of language in note-taking is governed mainly by the status of the language in the interpreters' language combination, i.e. whether it is an A- or a B-language, and much less by its status......, on the other. The aim of the study is to explore what governs conference interpreters' choice of language for their notes. The categories traditionally used to discuss, describe and explain this choice are those of 'source language' and 'target language', and these categories are therefore subject...

  13. Zonal Articular Cartilage Possesses Complex Mechanical Behavior Spanning Multiple Length Scales: Dependence on Chemical Heterogeneity, Anisotropy, and Microstructure

    Science.gov (United States)

    Wahlquist, Joseph A.

    This work focused on characterizing the mechanical behavior of biological material in physiologically relevant conditions and at sub millimeter length scales. Elucidating the time, length scale, and directionally dependent mechanical behavior of cartilage and other biological materials is critical to adequately recapitulate native mechanosensory cues for cells, create computational models that mimic native tissue behavior, and assess disease progression. This work focused on three broad aspects of characterizing the mechanical behavior of articular cartilage. First, we sought to reveal the causes of time-dependent deformation and variation of mechanical properties with distance from the articular surface. Second, we investigated size dependence of mechanical properties. Finally, we examined material anisotropy of both the calcified and uncalcified tissues of the osteochondral interface. This research provides insight into how articular cartilage serves to support physiologic loads and simultaneously sustain chondrocyte viability.

  14. Effect of crosslinker length on the elastic and compression modulus of poly(acrylamide) nanocomposite hydrogels

    International Nuclear Information System (INIS)

    Zaragoza, J; Chang, A; Asuri, P

    2017-01-01

    Polymer hydrogelshave shown to exhibit improved properties upon the addition of nanoparticles; however, the mechanical underpinnings behind these enhancements have not been fully elucidated. Moreover, fewer studies have focused on developing an understanding of how polymer parameters affect the nanoparticle-mediated enhancements. In this study, we investigated the elastic properties of silica nanoparticle-reinforced poly(acrylamide) hydrogels synthesized using crosslinkers of various lengths. Crosslinker length positively affected the mechanical properties of hydrogels that were synthesized with or without nanoparticles. However the degree of nanoparticle enhancement was negatively correlated to crosslinker length. Our findings enable the understanding of the respective roles of nanoparticle and polymer properties on nanoparticle-mediated enhancement of hydrogels and thereby the development of next-generation nanocomposite materials. (paper)

  15. Thin film materials: stress, defect formation, and surface evolution

    National Research Council Canada - National Science Library

    Freund, L. B; Suresh, S

    2003-01-01

    ... scientific basis with which stress, deformation and failure in thin film materials can be characterized, an attempt is also made to link the scientific concepts to a broad range of practical applications through example problems, historical notes, case studies and exercises. Of particular interest to engineers, materials scientists and physicist...

  16. Multiscale experimental mechanics of hierarchical carbon-based materials.

    Science.gov (United States)

    Espinosa, Horacio D; Filleter, Tobin; Naraghi, Mohammad

    2012-06-05

    Investigation of the mechanics of natural materials, such as spider silk, abalone shells, and bone, has provided great insight into the design of materials that can simultaneously achieve high specific strength and toughness. Research has shown that their emergent mechanical properties are owed in part to their specific self-organization in hierarchical molecular structures, from nanoscale to macroscale, as well as their mixing and bonding. To apply these findings to manmade materials, researchers have devoted significant efforts in developing a fundamental understanding of multiscale mechanics of materials and its application to the design of novel materials with superior mechanical performance. These efforts included the utilization of some of the most promising carbon-based nanomaterials, such as carbon nanotubes, carbon nanofibers, and graphene, together with a variety of matrix materials. At the core of these efforts lies the need to characterize material mechanical behavior across multiple length scales starting from nanoscale characterization of constituents and their interactions to emerging micro- and macroscale properties. In this report, progress made in experimental tools and methods currently used for material characterization across multiple length scales is reviewed, as well as a discussion of how they have impacted our current understanding of the mechanics of hierarchical carbon-based materials. In addition, insight is provided into strategies for bridging experiments across length scales, which are essential in establishing a multiscale characterization approach. While the focus of this progress report is in experimental methods, their concerted use with theoretical-computational approaches towards the establishment of a robust material by design methodology is also discussed, which can pave the way for the development of novel materials possessing unprecedented mechanical properties. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. NCEP Internal Office Notes

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The National Centers for Environmental Prediction (NCEP) and its predecessors have produced internal publications, known as Office Notes, since the mid-1950's. In...

  18. Opening of new field in material science and technology by materials irradiation research

    Energy Technology Data Exchange (ETDEWEB)

    Kurishita, Hiroaki [Tohoku Univ., Sendai (Japan). Inst. for Materials Research

    1998-03-01

    It is believed that high energy particle irradiation causes severe degradation of materials, and great efforts have been made to reveal the underlying mechanism of such degradation. However, recent progress of the developments of irradiation rigs performed in the Japan Materials Testing Reactor (JMTR) and materials fabrication techniques has enabled to change our understanding of radiation effects on materials from the above pessimistic one to the very challenging one, i.e., irradiation has the beneficial effect of producing new phenomena and/or innovative materials that will not be available without irradiation. An example to be noted is that irradiation with neutrons in JMTR greatly improved the ductility of less ductile metals. This ductility improvement due to irradiation is directly opposite to irradiation embrittlement and is called radiation induced ductilization (RIDU). In this presentation the significance of RIDU and its mechanism will be stated. (author)

  19. Polyphonic Piano Transcription with a Note-Based Music Language Model

    Directory of Open Access Journals (Sweden)

    Qi Wang

    2018-03-01

    Full Text Available This paper proposes a note-based music language model (MLM for improving note-level polyphonic piano transcription. The MLM is based on the recurrent structure, which could model the temporal correlations between notes in music sequences. To combine the outputs of the note-based MLM and acoustic model directly, an integrated architecture is adopted in this paper. We also propose an inference algorithm, in which the note-based MLM is used to predict notes at the blank onsets in the thresholding transcription results. The experimental results show that the proposed inference algorithm improves the performance of note-level transcription. We also observe that the combination of the restricted Boltzmann machine (RBM and recurrent structure outperforms a single recurrent neural network (RNN or long short-term memory network (LSTM in modeling the high-dimensional note sequences. Among all the MLMs, LSTM-RBM helps the system yield the best results on all evaluation metrics regardless of the performance of acoustic models.

  20. Online access to doctors' notes: patient concerns about privacy.

    Science.gov (United States)

    Vodicka, Elisabeth; Mejilla, Roanne; Leveille, Suzanne G; Ralston, James D; Darer, Jonathan D; Delbanco, Tom; Walker, Jan; Elmore, Joann G

    2013-09-26

    Offering patients online access to medical records, including doctors' visit notes, holds considerable potential to improve care. However, patients may worry about loss of privacy when accessing personal health information through Internet-based patient portals. The OpenNotes study provided patients at three US health care institutions with online access to their primary care doctors' notes and then collected survey data about their experiences, including their concerns about privacy before and after participation in the intervention. To identify patients' attitudes toward privacy when given electronic access to their medical records, including visit notes. The design used a nested cohort study of patients surveyed at baseline and after a 1-year period during which they were invited to read their visit notes through secure patient portals. Participants consisted of 3874 primary care patients from Beth Israel Deaconess Medical Center (Boston, MA), Geisinger Health System (Danville, PA), and Harborview Medical Center (Seattle, WA) who completed surveys before and after the OpenNotes intervention. The measures were patient-reported levels of concern regarding privacy associated with online access to visit notes. 32.91% of patients (1275/3874 respondents) reported concerns about privacy at baseline versus 36.63% (1419/3874 respondents) post-intervention. Baseline concerns were associated with non-white race/ethnicity and lower confidence in communicating with doctors, but were not associated with choosing to read notes or desire for continued online access post-intervention (nearly all patients with notes available chose to read them and wanted continued access). While the level of concern among most participants did not change during the intervention, 15.54% (602/3874 respondents, excluding participants who responded "don't know") reported more concern post-intervention, and 12.73% (493/3874 respondents, excluding participants who responded "don't know") reported less

  1. Microelectronics to nanoelectronics materials, devices & manufacturability

    CERN Document Server

    Kaul, Anupama B

    2012-01-01

    Composed of contributions from top experts, Microelectronics to Nanoelectronics: Materials, Devices and Manufacturability offers a detailed overview of important recent scientific and technological developments in the rapidly evolving nanoelectronics arena.Under the editorial guidance and technical expertise of noted materials scientist Anupama B. Kaul of California Institute of Technology's Jet Propulsion Lab, this book captures the ascent of microelectronics into the nanoscale realm. It addresses a wide variety of important scientific and technological issues in nanoelectronics research and

  2. The Time of Materiality

    Directory of Open Access Journals (Sweden)

    Estrid Sørensen

    2007-01-01

    Full Text Available While time and space form a classic duality in social science, this article demonstrates a perspective on time, space and materiality as a core trinity. As a prominent figure in contemporary discussions on materiality in the social sciences Science and Technology Studies (STS emphasizes relational approaches. STS however lacks a clear relational definition of materiality and tends instead to focus on the agency of entities, on for instance material agency. The article suggests a relational definition of materiality and notes that this move implies turning the question of the time of materiality into an empirical question. It is argued that relational materiality must be studied spatially, and thus a spatial approach describing patterns of relations is presented. Based on field work in a primary school classroom and computer lab, three materials are analyzed: the blackboard, a bed-loft and an online 3D virtual environment. The empirical descriptions depict three different materialities, and it is shown how time is formed differently in each of them. Time, it is argued, is an emergent and characterizing aspect of materialities as spatial formations. URN: urn:nbn:de:0114-fqs070122

  3. Intraflagellar transport particle size scales inversely with flagellar length: revisiting the balance-point length control model.

    Science.gov (United States)

    Engel, Benjamin D; Ludington, William B; Marshall, Wallace F

    2009-10-05

    The assembly and maintenance of eukaryotic flagella are regulated by intraflagellar transport (IFT), the bidirectional traffic of IFT particles (recently renamed IFT trains) within the flagellum. We previously proposed the balance-point length control model, which predicted that the frequency of train transport should decrease as a function of flagellar length, thus modulating the length-dependent flagellar assembly rate. However, this model was challenged by the differential interference contrast microscopy observation that IFT frequency is length independent. Using total internal reflection fluorescence microscopy to quantify protein traffic during the regeneration of Chlamydomonas reinhardtii flagella, we determined that anterograde IFT trains in short flagella are composed of more kinesin-associated protein and IFT27 proteins than trains in long flagella. This length-dependent remodeling of train size is consistent with the kinetics of flagellar regeneration and supports a revised balance-point model of flagellar length control in which the size of anterograde IFT trains tunes the rate of flagellar assembly.

  4. Plantar fascia coronal length: a new parameter for plantar fascia assessment.

    Science.gov (United States)

    Sari, Ahmet Sinan; Demircay, Emre; Cakmak, Gokhan; Sahin, M Sukru; Tuncay, I Cengiz; Altun, Suleyman

    2015-01-01

    The effects of gender and various anthropometric variables were previously reported as significant predictors of plantar fascia thickness. Although a strong correlation between either the body weight or body mass index (BMI) and plantar fascia thickness were not demonstrated, a moderate relation was stated. We retrospectively investigated the role of gender, height, weight, and body mass index on plantar fascia thickness at the calcaneal origin (PFCO) and 1 cm distal from the calcaneal origin (PF1cm) and the coronal length of the plantar fascia at the calcaneal origin (CLPF) in healthy subjects. The PFCO, PF1cm, and CLPF were retrospectively measured from magnetic resonance images of 100 healthy subjects. The gender, height, weight, and body mass index of the participants were also noted. Gender was a predictive factor for the length of the CLPF. The subjects with a BMI >25 kg/m(2) had a significantly greater PFCO, PF1cm, and CLPF. Height was mildly and BMI and weight were moderately related to the PFCO. However the CLPF showed a better correlation with height, BMI, and weight than that of plantar fascia thickness. CLPF better reflected the role of weight, BMI, and height than its thickness. It is a new parameter that could be valuable in the evaluation of plantar fascia disorders. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  5. A note on the effect of the fiber curvature on the micromechanical behavior of natural fiber reinforced thermoplastic composites

    Directory of Open Access Journals (Sweden)

    M. A. Escalante-Solis

    2015-12-01

    Full Text Available To better understand the role of the fiber curvature on the tensile properties of short-natural-fiber reinforced composites, a photoelastic model and a finite element analysis were performed in a well characterized henequen fiber-high density polyethylene composite material. It was hypothesized that the angle of orientation of the inclusion and the principal material orientation with respect to the applied load was very important in the reinforcement mechanics. From the photoelastic and finite element analysis it was found that the stress distribution around the fiber inclusion was different on the concave side from that observed on the convex side and an efficient length of stress transfer was estimated to be approximately equal to one third the average fiber length. This approach was used to predict the short-natural-fiber reinforced composite mechanical properties using probabilistic functions modifications of the rule of mixtures models developed by Fukuda-Chow and the Fukuda-Kawata. Recognizing the inherent flexibility that curves the natural fibers during processing, the consideration of a length of one third of the average length l should improve the accuracy of the calculations of the mechanical properties using theoretical models.

  6. Suicide Note Classification Using Natural Language Processing: A Content Analysis.

    Science.gov (United States)

    Pestian, John; Nasrallah, Henry; Matykiewicz, Pawel; Bennett, Aurora; Leenaars, Antoon

    2010-08-04

    Suicide is the second leading cause of death among 25-34 year olds and the third leading cause of death among 15-25 year olds in the United States. In the Emergency Department, where suicidal patients often present, estimating the risk of repeated attempts is generally left to clinical judgment. This paper presents our second attempt to determine the role of computational algorithms in understanding a suicidal patient's thoughts, as represented by suicide notes. We focus on developing methods of natural language processing that distinguish between genuine and elicited suicide notes. We hypothesize that machine learning algorithms can categorize suicide notes as well as mental health professionals and psychiatric physician trainees do. The data used are comprised of suicide notes from 33 suicide completers and matched to 33 elicited notes from healthy control group members. Eleven mental health professionals and 31 psychiatric trainees were asked to decide if a note was genuine or elicited. Their decisions were compared to nine different machine-learning algorithms. The results indicate that trainees accurately classified notes 49% of the time, mental health professionals accurately classified notes 63% of the time, and the best machine learning algorithm accurately classified the notes 78% of the time. This is an important step in developing an evidence-based predictor of repeated suicide attempts because it shows that natural language processing can aid in distinguishing between classes of suicidal notes.

  7. Controlling the optical path length in turbid media using differential path-length spectroscopy: fiber diameter dependence

    NARCIS (Netherlands)

    Kaspers, O. P.; Sterenborg, H. J. C. M.; Amelink, A.

    2008-01-01

    We have characterized the path length for the differential path-length spectroscopy (DPS) fiber optic geometry for a wide range of optical properties and for fiber diameters ranging from 200 mu m to 1000 mu m. Phantom measurements show that the path length is nearly constant for scattering

  8. Optimized adhesives for strong, lightweight, damage-resistant, nanocomposite materials: new insights from natural materials

    International Nuclear Information System (INIS)

    Hansma, P K; Turner, P J; Ruoff, R S

    2007-01-01

    From our investigations of natural composite materials such as abalone shell and bone we have learned the following. (1) Nature is frugal with resources: it uses just a few per cent glue, by weight, to glue together composite materials. (2) Nature does not avoid voids. (3) Nature makes optimized glues with sacrificial bonds and hidden length. We discuss how optimized adhesives combined with high specific stiffness/strength structures such as carbon nanotubes or graphene sheets could yield remarkably strong, lightweight, and damage-resistant materials

  9. Optimized adhesives for strong, lightweight, damage-resistant, nanocomposite materials: new insights from natural materials

    Energy Technology Data Exchange (ETDEWEB)

    Hansma, P K [Physics Department, Broida Hall, University of California, Santa Barbara, CA 93106 (United States); Turner, P J [Physics Department, Broida Hall, University of California, Santa Barbara, CA 93106 (United States); Ruoff, R S [Department of Mechanical Engineering, Northwestern University, 2145 Sheridan Road, Evanston, IL 60208-3111 (United States)

    2007-01-31

    From our investigations of natural composite materials such as abalone shell and bone we have learned the following. (1) Nature is frugal with resources: it uses just a few per cent glue, by weight, to glue together composite materials. (2) Nature does not avoid voids. (3) Nature makes optimized glues with sacrificial bonds and hidden length. We discuss how optimized adhesives combined with high specific stiffness/strength structures such as carbon nanotubes or graphene sheets could yield remarkably strong, lightweight, and damage-resistant materials.

  10. Note-taking and Handouts in The Digital Age

    OpenAIRE

    Stacy, Elizabeth Moore; Cain, Jeff

    2015-01-01

    Most educators consider note-taking a critical component of formal classroom learning. Advancements in technology such as tablet computers, mobile applications, and recorded lectures are altering classroom dynamics and affecting the way students compose and review class notes. These tools may improve a student’s ability to take notes, but they also may hinder learning. In an era of dynamic technology developments, it is important for educators to routinely examine and evaluate influences on f...

  11. The Effect of Gestational Age on Axial Length of the Eyes of Premature Infants

    Directory of Open Access Journals (Sweden)

    Mehmet Ali Sekeroglu

    2016-01-01

    Full Text Available Aim: The aim of the present study is to evaluate the axial length of the eyes of premature infants without retinopathy of prematurity and to document the relationship with gestational age and changes as infants grew-up. Material and Method: The axial length of the eyes were measured by using a mobile A-scan ultrasonographic biometry device just before the first retinopathy of prematurity screening examination and 4-weeks thereafter. Results: One-hundred and thirty-six infants with a mean gestational age of 31,7±2,7 weeks and a birth-weight of 1561.0±379.3 g were included in the study. Axial length measurements were done at a mean postconceptional age of 35.8 ±2.6 (31-40 and 39.8±2.7 (35-44 weeks, consecutively. The mean axial length at first and second visits were 16.43±0.42 mm (15.28-17.13 and 16.69±0.41 mm (15.60-17.70, consecutively (p

  12. Short Rayleigh Length Free Electron Lasers

    CERN Document Server

    Crooker, P P; Armstead, R L; Blau, J

    2004-01-01

    Conventional free electron laser (FEL) oscillators minimize the optical mode volume around the electron beam in the undulator by making the resonator Rayleigh length about one third of the undulator length. This maximizes gain and beam-mode coupling. In compact configurations of high-power infrared FELs or moderate power UV FELs, the resulting optical intensity can damage the resonator mirrors. To increase the spot size and thereby reduce the optical intensity at the mirrors below the damage threshold, a shorter Rayleigh length can be used, but the FEL interaction is significantly altered. A new FEL interaction is described and analyzed with a Rayleigh length that is only one tenth the undulator length, or less. The effect of mirror vibration and positioning are more critical in the short Rayleigh length design, but we find that they are still within normal design tolerances.

  13. Parallel Note-Taking: A Strategy for Effective Use of Webnotes

    Science.gov (United States)

    Pardini, Eleanor A.; Domizi, Denise P.; Forbes, Daniel A.; Pettis, Gretchen V.

    2005-01-01

    Many instructors supply online lecture notes but little attention has been given to how students can make the best use of this resource. Based on observations of student difficulties with these notes, a strategy called parallel note-taking was developed for using online notes. The strategy is a hybrid of research-proven strategies for effective…

  14. Note-taking Strategies and Academic Achievement

    OpenAIRE

    Haghverdi, Hamid; Biria, Reza; Karimi, Lotfollah

    2014-01-01

    The purpose of the present article is two fold. That is, revealing the significance, underlying theory and findings concerning note-taking in the literature related and exploring, through a survey study, the Iranian professors‘ and students‘ attitudes towards the effect of teaching note-taking strategies on the students‘ academic achievement. To this end, many previous studies were reviewed and we knew that many scholars, conducting empirical studies, surveys and interviews, have highlighted ...

  15. Writing a Condolence Note

    Science.gov (United States)

    ... through the eyes of others. For example, a mother whose son had died found out that her ... few suggestions on ending your condolence note: “Our love and support will always be here for you.” “ ...

  16. Development of knowledge base system linked to material database

    International Nuclear Information System (INIS)

    Kaji, Yoshiyuki; Tsuji, Hirokazu; Mashiko, Shinichi; Miyakawa, Shunichi; Fujita, Mitsutane; Kinugawa, Junichi; Iwata, Shuichi

    2002-01-01

    The distributed material database system named 'Data-Free-Way' has been developed by four organizations (the National Institute for Materials Science, the Japan Atomic Energy Research Institute, the Japan Nuclear Cycle Development Institute, and the Japan Science and Technology Corporation) under a cooperative agreement in order to share fresh and stimulating information as well as accumulated information for the development of advanced nuclear materials, for the design of structural components, etc. In order to create additional values of the system, knowledge base system, in which knowledge extracted from the material database is expressed, is planned to be developed for more effective utilization of Data-Free-Way. XML (eXtensible Markup Language) has been adopted as the description method of the retrieved results and the meaning of them. One knowledge note described with XML is stored as one knowledge which composes the knowledge base. Since this knowledge note is described with XML, the user can easily convert the display form of the table and the graph into the data format which the user usually uses. This paper describes the current status of Data-Free-Way, the description method of knowledge extracted from the material database with XML and the distributed material knowledge base system. (author)

  17. Hydrogen bonded columnar liquid crystals for nanostructured functional materials

    NARCIS (Netherlands)

    Fitié, C.F.C.

    2010-01-01

    Many functional materials rely on a well-organized internal structure for their functional properties. The length scale of this organization can vary from the atomic level (e.g., piezoelectric crystals) to a macroscopic length scale exceeding the dimensions of individual molecules (e.g., porous

  18. Notes on the IMACON 500 streak camera system

    International Nuclear Information System (INIS)

    Clendenin, J.E.

    1985-01-01

    The notes provided are intended to supplement the instruction manual for the IMACON 500 streak camera system. The notes cover the streak analyzer, instructions for timing the streak camera, and calibration

  19. Suicide Note Classification Using Natural Language Processing: A Content Analysis

    Directory of Open Access Journals (Sweden)

    John Pestian

    2010-08-01

    Full Text Available Suicide is the second leading cause of death among 25–34 year olds and the third leading cause of death among 15–25 year olds in the United States. In the Emergency Department, where suicidal patients often present, estimating the risk of repeated attempts is generally left to clinical judgment. This paper presents our second attempt to determine the role of computational algorithms in understanding a suicidal patient’s thoughts, as represented by suicide notes. We focus on developing methods of natural language processing that distinguish between genuine and elicited suicide notes. We hypothesize that machine learning algorithms can categorize suicide notes as well as mental health professionals and psychiatric physician trainees do. The data used are comprised of suicide notes from 33 suicide completers and matched to 33 elicited notes from healthy control group members. Eleven mental health professionals and 31 psychiatric trainees were asked to decide if a note was genuine or elicited. Their decisions were compared to nine different machine-learning algorithms. The results indicate that trainees accurately classified notes 49% of the time, mental health professionals accurately classified notes 63% of the time, and the best machine learning algorithm accurately classified the notes 78% of the time. This is an important step in developing an evidence-based predictor of repeated suicide attempts because it shows that natural language processing can aid in distinguishing between classes of suicidal notes.

  20. Length dependent properties of SNS microbridges

    International Nuclear Information System (INIS)

    Sauvageau, J.E.; Jain, R.K.; Li, K.; Lukens, J.E.; Ono, R.H.

    1985-01-01

    Using an in-situ, self-aligned deposition scheme, arrays of variable length SNS junctions in the range of 0.05 μm to 1 μm have been fabricated. Arrays of SNS microbridges of lead-copper and niobium-copper fabricated using this technique have been used to study the length dependence, at constant temperature, of the critical current I and bridge resistance R /SUB d/ . For bridges with lengths pounds greater than the normal metal coherence length xi /SUB n/ (T), the dependence of I /SUB c/ on L is consistent with an exponential dependence on the reduced length l=L/xi /SUB n/ (T). For shorter bridges, deviations from this behavior is seen. It was also found that the bridge resistance R /SUB d/ does not vary linearly with the geometric bridge length but appears to approach a finite value as L→O

  1. Medical students' note-taking in a medical biochemistry course: an initial exploration.

    Science.gov (United States)

    Morrison, Elizabeth H; McLaughlin, Calvin; Rucker, Lloyd

    2002-04-01

    Beginning medical students spend numerous hours every week attending basic science lectures and taking notes. Medical faculty often wonder whether they should give students pre-printed instructors' notes before lectures. Proponents of this strategy argue that provided notes enhance learning by facilitating the accurate transmission of information, while opponents counter that provided notes inhibit students' cognitive processing or even discourage students from attending lectures. Little if any research has directly addressed medical students' note-taking or the value of providing instructors' notes. The educational literature does suggest that taking lecture notes enhances university students' learning. University students perform best on post-lecture testing if they review a combination of provided notes and their own personal notes, particularly if the provided notes follow a 'skeletal' format that encourages active note-taking.

  2. Natural-orifice transluminal endoscopic surgery (NOTES) in Europe: summary of the working group reports of the Euro-NOTES meeting 2010

    DEFF Research Database (Denmark)

    Meining, A; Feussner, H; Swain, P

    2011-01-01

    The fourth Euro-NOTES workshop took place in September 2010 and focused on enabling intensive scientific dialogue and interaction between participants to discuss the state of the practice and development of natural-orifice transluminal endoscopic surgery (NOTES) in Europe. Five working groups were...... collaboration and indications, robotics and platforms, and matters related to training and education. This review summarizes consensus statements of the working groups to give an overview of what has been achieved so far and what might be relevant for research related to NOTES in the near future....

  3. Suicide Notes in Hong Kong in 2000

    Science.gov (United States)

    Wong, Paul W. C.; Yeung, April W. M.; Chan, Wincy S. C.; Yip, Paul S. F.; Tang, Arthur K. H.

    2009-01-01

    Suicide notes have been regarded as one of the most informative data sources to understand the reasons why people commit suicide. However, there is a paucity of suicide note studies, leaving researchers with an assumption that this phenomenon remains static over time. This study examines this assumption by comparing the characteristics of…

  4. Elaboration of building materials from industrial waste from solid granular diatomaceous earth; Elaboracion de material de construccion a partir de residuos industriales solidos granulares procedentes de tierras diatomaceas

    Energy Technology Data Exchange (ETDEWEB)

    Del Angel S, A.

    2015-07-01

    In this work the initial characterization of granular solid industrial waste from diatomaceous earth was carried out using techniques of Scanning Electron Microscopy and X-ray Diffraction. In a second stage leaching of the material was undertaken to the US Patent Number 5, 376,000 and 5, 356,601 obtaining the samples M1-S ph 2, M1-L ph, M1-S ph 10 and M1-L ph 10. In the third stage a new characterization of the samples obtained with the techniques of Scanning Electron Microscopy, X-ray Diffraction and Atomic Absorption Spectrometry was performed, the latter in order to determine the efficiency percentage of the leaching process. In the fourth stage the specimens for performing mechanical, physical and chemical tests were manufactured, using molds as PVC pipes of 1 inch in diameter and 2 inches in length, with a composition of 50% of diatomaceous earth and 50% of cement produced in each. Finally, in the fifth stage mechanical testing (compression resistance), physical (moisture absorption rate) and chemical (composition and structure of the material) are performed. In the last stage, when conducting mechanical testing with the test specimens, the presence of bubbles enclosed in each obtaining erroneous results noted, so it was necessary to develop the specimens again, obtaining in this occasion concentrations of 20:80, 40:60, 60:40 and 80:20 of diatomaceous earth with the cement. These results were analyzed to determine if the used material is suitable for the production of building materials such as bricks or partitions, being demonstrated by the tests carried out if they are eligible. (Author)

  5. Effective Debye length in closed nanoscopic systems: a competition between two length scales.

    Science.gov (United States)

    Tessier, Frédéric; Slater, Gary W

    2006-02-01

    The Poisson-Boltzmann equation (PBE) is widely employed in fields where the thermal motion of free ions is relevant, in particular in situations involving electrolytes in the vicinity of charged surfaces. The applications of this non-linear differential equation usually concern open systems (in osmotic equilibrium with an electrolyte reservoir, a semi-grand canonical ensemble), while solutions for closed systems (where the number of ions is fixed, a canonical ensemble) are either not appropriately distinguished from the former or are dismissed as a numerical calculation exercise. We consider herein the PBE for a confined, symmetric, univalent electrolyte and quantify how, in addition to the Debye length, its solution also depends on a second length scale, which embodies the contribution of ions by the surface (which may be significant in high surface-to-volume ratio micro- or nanofluidic capillaries). We thus establish that there are four distinct regimes for such systems, corresponding to the limits of the two parameters. We also show how the PBE in this case can be formulated in a familiar way by simply replacing the traditional Debye length by an effective Debye length, the value of which is obtained numerically from conservation conditions. But we also show that a simple expression for the value of the effective Debye length, obtained within a crude approximation, remains accurate even as the system size is reduced to nanoscopic dimensions, and well beyond the validity range typically associated with the solution of the PBE.

  6. Engineering behavior of small-scale foundation piers constructed from alternative materials

    Science.gov (United States)

    Prokudin, Maxim Mikhaylovich

    Testing small-scale prototype pier foundations to evaluate engineering behavior is an alternative to full-scale testing that facilitates testing of several piers and pier groups at relatively low cost. In this study, various pier systems and pier groups at one tenth scale were subjected to static vertical loading under controlled conditions to evaluate stiffness, bearing capacity, and group efficiency. Pier length, material properties and methods of installation were evaluated. Pier length to diameter ratios varied between four and eight. A unique soil pit with dimensions of 2.1 m in width, 1.5 m in length and 2.0 m in depth was designed to carry out this research. The test pit was filled with moisture conditioned and compacted Western Iowa loess. A special load test frame was designed and fabricated to provide up to 25,000 kg vertical reaction force for load testing. A load cell and displacement instrumentation was setup to capture the load test data. Alternative materials to conventional cement concrete were studied. The pier materials evaluated in this study included compacted aggregate, cement stabilized silt, cementitious grouts, and fiber reinforced silt. Key findings from this study demonstrated that (1) the construction method influences the behavior of aggregate piers, (2) the composition of the pier has a significant impact on the stiffness, (3) group efficiencies were found to be a function of pier length and pier material, (4) in comparison to full-scale testing the scaled piers were found to produce a stiffer response with load-settlement and bearing capacities to be similar. Further, although full-scale test results were not available for all pier materials, the small-scale testing provided a means for comparing results between pier systems. Finally, duplicate pier tests for a given length and material were found to be repeatable.

  7. Sighting optics including an optical element having a first focal length and a second focal length

    Science.gov (United States)

    Crandall, David Lynn [Idaho Falls, ID

    2011-08-01

    One embodiment of sighting optics according to the teachings provided herein may include a front sight and a rear sight positioned in spaced-apart relation. The rear sight includes an optical element having a first focal length and a second focal length. The first focal length is selected so that it is about equal to a distance separating the optical element and the front sight and the second focal length is selected so that it is about equal to a target distance. The optical element thus brings into simultaneous focus, for a user, images of the front sight and the target.

  8. Influence of the Particle Length of Carbon Nanotube for Pool Boiling Critical Heat Flux Enhancement of Nanofluids

    International Nuclear Information System (INIS)

    Park, Sung Seek; Kim, Yong Hwan; Kim, Nam Jin

    2013-01-01

    The results of this experiment were that the CHF of the two nanofluids increased along with the volumetric fraction until 0.001 vol%, and the two types of nanofluids are the highest CHF at 0.001 vol%. Also, the results show clearly that the rate of CHF increase of the CM-100 MWCNT nanofluid with longer-length nanoparticles is higher than that of the CM-95 MWNCT nanofluid. These results indicate that the length of carbon nanotube influences the pool boiling CHF of carbon nanotube nanofluid and that long-length MWCNT, as above-noted, offers a superior effect in this regard. Boiling heat transfer is used in a variety of industrial processes and applications, such as refrigeration, power generation, heat exchangers, cooling of high-power electronics components and cooling of nuclear reactors. The critical heat flux (CHF) phenomenon is the thermal limit during a boiling heat transfer phase change; at the CHF point the heat transfer is maximised, followed by a drastic degradation after the CHF point. The consequence is a substantial increase in wall temperature which may result in physical failure phenomenon of heat transfer systems. Therefore, the CHF is important being considered in the cooling device design, such as nuclear reactor and nuclear fuels, steam generators, high-density electronic component, etc. And, CHF enhancement is essential for safety of heat transfer system. Recently, CHF reported increased when applied to the nanofluids, with its high (higher-than-base-fluid) thermal characteristic in the nuclear power plant system. Therefore, in this study, carried out the pool boiling CHF experiments by the particle length using carbon nanotube nanofluids, and the results are compared and analyzed for the CHF enhancement. The pool boiling CHF of experiments of carbon nanotube nanofluids carried out by the length of particles and the various concentrations

  9. Pore size distribution, moisture distribution, and shrinkage of porous materials - as determined by computer analysis (MATSORP) of measured sorption data

    DEFF Research Database (Denmark)

    Nielsen, Lauge Fuglsang

    1999-01-01

    Text note for the Summer school on 'Hydration and Microstructure of High Performance Concrete', held at Dept. Struct. Eng. and Materials, DTU, august 16-25, 1999......Text note for the Summer school on 'Hydration and Microstructure of High Performance Concrete', held at Dept. Struct. Eng. and Materials, DTU, august 16-25, 1999...

  10. length-weight relationhip of freshwater wild fish species

    African Journals Online (AJOL)

    Dr Naeem

    2012-06-21

    Jun 21, 2012 ... Length-weight (LWR) and length-length relationships (LLR) were determined for a freshwater catfish ... Key words: Mystus bleekeri, length-weight relationship, length-length relationship, predictive equations. INTRODUCTION. Mystus bleekeri (freshwater catfish Day, 1877), locally ..... fish farmers, Aquacult.

  11. The quality of operative notes at a general surgery unit.

    Science.gov (United States)

    Rogers, A; Bunting, M; Atherstone, A

    2008-09-01

    With the increasingly litigious nature of medical practice, accurate documentation is critical. This is particularly true for operative procedures, and medical councils have identified this and published guidelines to aid surgeons. However, these remain a frequently cited weakness in their defence in medico-legal cases. This study assessed the accuracy of operative notes in a general surgery unit in order to improve our practice. An audit of 100 consecutive operative notes was performed, and notes were assessed using the Royal College of Surgeons guidelines. The quality of note-taking of trainees was compared with that of consultant surgeons. A series of operation note pro formas was designed in response to the findings. Of the notes, 66% were completed by trainees. The vast majority of notes had no diagram to demonstrate the surgical findings or illustrate the actions. Specialist surgeons were more likely to describe the actions accurately, but less likely to describe wound closure methods or dressings used. They were also less likely to complete adequate postoperative orders. This study identifies key areas of weakness in our operative note-keeping. Pro formas should be introduced and made available for commonly performed procedures, and diagrams should be used wherever possible.

  12. Metal halide arc discharge lamp having short arc length

    Science.gov (United States)

    Muzeroll, Martin E. (Inventor)

    1994-01-01

    A metal halide arc discharge lamp includes a sealed light-transmissive outer jacket, a light-transmissive shroud located within the outer jacket and an arc tube assembly located within the shroud. The arc tube assembly includes an arc tube, electrodes mounted within the arc tube and a fill material for supporting an arc discharge. The electrodes have a spacing such that an electric field in a range of about 60 to 95 volts per centimeter is established between the electrodes. The diameter of the arc tube and the spacing of the electrodes are selected to provide an arc having an arc diameter to arc length ratio in a range of about 1.6 to 1.8. The fill material includes mercury, sodium iodide, scandium tri-iodide and a rare gas, and may include lithium iodide. The lamp exhibits a high color rendering index, high lumen output and high color temperature.

  13. Utilization of raw material from early thinnings; Ensiharvennuspuun hyoedyntaeminen

    Energy Technology Data Exchange (ETDEWEB)

    Alen, R; Marttina, M; Toivanen, J [Jyvaeskylae Univ. (Finland). Dept. of Chemistry

    1997-12-01

    Wood material from early thinnings is one of the most potential new material reserves (4 - 6 million m{sup 3}) for industrial purposes. However, the prerequisites for an enhanced utilisation of this reserve would be, besides more efficient logging, debarking, and chipping, an optimal fractionation of wood material into energy and fibre production. The aim of this project was to promote the use of first-thinning wood as a competitive raw material for energy production by increasing the potential utilisation of the corresponding wood resource for chemical pulping. During the year 1996 the variation of fibre length distribution within the stem and top (total height of 12 m) of a 27-years-old pine wood (Pinus sylvestris) was determined. Tentative calculations indicated that about 67 % of the wood dry matter consists of fibres having an average fibre length more than 2 mm. It was considered that most of this fraction with high quality fibre properties could be recovered and used for pulping. In addition, the detailed FTIR analysis of different samples from the same pine wood showed that there was an adequate correlation between the FTIR spectrometric data and the fibre length averages. (orig.)

  14. Euro-NOTES Status Paper: from the concept to clinical practice.

    Science.gov (United States)

    Fuchs, K H; Meining, A; von Renteln, D; Fernandez-Esparrach, G; Breithaupt, W; Zornig, C; Lacy, A

    2013-05-01

    The concept of natural orifice transluminal endoscopic surgery (NOTES) consists of the reduction of access trauma by using a natural orifice access to the intra-abdominal cavity. This could possibly lead to less postoperative pain, quicker recovery from surgery, fewer postoperative complications, fewer wound infections, and fewer long-term problems such as hernias. The Euro-NOTES Foundation has organized yearly meetings to work on this concept to bring it safely into clinical practice. The aim of this Euro-NOTES status update is to assess the yearly scientific working group reports and provide an overview on the current clinical practice of NOTES procedures. After the Euro-NOTES meeting 2011 in Frankfurt, Germany, an analysis was started regarding the most important topics of the European working groups. All prospectively documented information was gathered from Euro-NOTES and D-NOTES working groups from 2007 to 2011. The top five topics were analyzed. The statements of the working group activities demonstrate the growing information and changing insights. The most important selected topics were infection issue, peritoneal access, education and training, platforms and new technology, closure, suture, and anastomosis. The focus on research topics changed over time. The principle of hybrid access has overcome the technical and safety limitations of pure NOTES. Currently the following NOTES access routes are established for several indications: transvaginal access for cholecystectomy, appendectomy and colon resections; transesophageal access for myotomy; transgastric access for full-thickness small-tumor resections; and transanal/transcolonic access for rectal and colon resections. NOTES and hybrid NOTES techniques have emerged for all natural orifices and were introduced into clinical practice with a good safety record. There are different indications for different natural orifices. Each technique has been optimized for the purpose of finding a safe and realistic

  15. Density functional theory study of silodithiophene thiophenepyrrolopyrroledion-based small molecules: The effect of alkyl side chain length in electron donor materials

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Dong Kyun; Yeo, Hak; Kwak, Kyung Won [Dept. of Chemistry, Chung-Ang University, Seoul (Korea, Republic of); Yoon, Young Woon; Kim, Bong Soo [Photo-electronic Hybrids Research Center, Korea Institute of Science and Technology, Seoul (Korea, Republic of); Lee, Kyung Koo [Dept. of Chemistry, Kunsan National University, Gunsan (Korea, Republic of)

    2015-02-15

    Push–pull small molecules are promising electron-donor materials for organic solar cells. Thus, precise prediction of their electronic structures is of paramount importance to control the optical and electrical properties of the solar cells. Various types of alkyl chains are usually introduced to increase solubility and modify the morphology of the resulting molecular films. Here, using density functional theory (DFT) and time-dependent DFT (TD-DFT), we report the precise effect of increasing the length of the alkyl chain on the electronic structure of an electron donor molecule 6,60-((4,4-dialkyl-4H-silolo[3,2-b:4,5-b′]-dithiophene-2,6-diyl) bis(thiophene-5,2-diyl))bis(2,5-alkyl-3-(thiophen-2-yl) -2,5-dihydropyrrolo[3,4-c]pyrrole-1,4-dione) (DTS1TDPP). Alkyl groups were attached to the bridging position (silicon atom) of the fused rings and nitrogen atom of the pyrrolopyrroledione groups. We demonstrate that the alkyl groups do not perturb the highest occupied molecular orbital (HOMO) and lowest unoccupied molecular orbital (LUMO) energy levels, π-delocalized backbone structure, and UV–Vis absorption spectrum when they are placed at the least steric effect positions.

  16. The impact of length of stay on recovery measures in faith-based addiction treatment.

    Science.gov (United States)

    Lashley, Mary

    2018-03-30

    To determine the impact of length of stay among homeless men in faith-based residential addictions recovery on physical activity, depression, self-esteem, and nicotine dependence. A time series design was utilized to measure changes in the four quality measures at program entry and at 3, 6, and 9 months following admission. The sample consisted of 175 homeless residents enrolled in a faith-based residential recovery program. Paired t tests were used to determine the change in average instrument response from admission to each follow-up period. Analysis of variance (ANOVA) and Tukey posthoc tests were used to assess for differences in length of stay between demographic variables. Statistically significant improvements were noted in self-esteem and depressive symptomatology at 3 and 6 months following admission and in physical activity levels at 3 months following admission. Nicotine dependence scores declined at 3 and 6 months but were not statistically significant. Time spent in this faith-based spiritual recovery program had a significant impact on depression, self-esteem, and physical activity. Recommendations for future study include conducting research to analyze the relationship between distinct program elements and quality indicators and comparing faith-based programs to other similar programs and to publicly funded secular recovery programs. © 2018 Wiley Periodicals, Inc.

  17. U-Note: Capture the Class and Access it Everywhere

    DEFF Research Database (Denmark)

    Malacria, Sylvain; Pietrzak, Thomas; Tabard, Aurélien

    2011-01-01

    We present U-Note, an augmented teaching and learning system leveraging the advantages of paper while letting teachers and pupils benefit from the richness that digital media can bring to a lecture. U-Note provides automatic linking between the notes of the pupils’ notebooks and various events...... on three modules. U-Teach captures the context of the class: audio recordings, the whiteboard contents, together with the web pages, videos and slideshows displayed during the lesson. U-Study binds pupils’ paper notes (taken with an Anoto digital pen) with the data coming from U-Teach and lets pupils...

  18. Notes on the nesting of three species of Megachilinae in the Dubai Desert Conservation Reserve, UAE

    Directory of Open Access Journals (Sweden)

    Sarah Kathleen Gess

    2017-02-01

    Full Text Available Some observations on the nesting of three species belonging to phylogenetically interesting lineages of Megachilinae are presented. Published knowledge of the nesting of these species, Megachile (Maximegachile maxillosa Guérin-Méneville (Megachilini, Megachile (Eurymella patellimana Spinola (Megachilini, and Pseudoheriades grandiceps Peters (currently assigned to the Osmiini, is fragmentary making the notes presented here a worthwhile addition. The brood cells of M. maxillosa and of P. grandiceps, constructed from a mixture of resin and sand, were positioned in pre-existing cavities, trap-nests, above ground. The cells of the former are equal in diameter to the boring and are constructed in linear series. Those of the latter are small ovoid and are grouped to form a cluster. Megachile patellimana was nesting in burrows in compacted sandy ground beneath a plant and in the banks of an irrigation furrow. At the former site a female was carrying a freshly cut leaf piece and at the latter another was carrying a cut length of narrow, tough, green plastic. The nest contained a group of identical lengths of plastic, clearly a substitute for leaves.

  19. Elaboration of building materials from industrial waste from solid granular diatomaceous earth

    International Nuclear Information System (INIS)

    Del Angel S, A.

    2015-01-01

    In this work the initial characterization of granular solid industrial waste from diatomaceous earth was carried out using techniques of Scanning Electron Microscopy and X-ray Diffraction. In a second stage leaching of the material was undertaken to the US Patent Number 5, 376,000 and 5, 356,601 obtaining the samples M1-S ph 2, M1-L ph, M1-S ph 10 and M1-L ph 10. In the third stage a new characterization of the samples obtained with the techniques of Scanning Electron Microscopy, X-ray Diffraction and Atomic Absorption Spectrometry was performed, the latter in order to determine the efficiency percentage of the leaching process. In the fourth stage the specimens for performing mechanical, physical and chemical tests were manufactured, using molds as PVC pipes of 1 inch in diameter and 2 inches in length, with a composition of 50% of diatomaceous earth and 50% of cement produced in each. Finally, in the fifth stage mechanical testing (compression resistance), physical (moisture absorption rate) and chemical (composition and structure of the material) are performed. In the last stage, when conducting mechanical testing with the test specimens, the presence of bubbles enclosed in each obtaining erroneous results noted, so it was necessary to develop the specimens again, obtaining in this occasion concentrations of 20:80, 40:60, 60:40 and 80:20 of diatomaceous earth with the cement. These results were analyzed to determine if the used material is suitable for the production of building materials such as bricks or partitions, being demonstrated by the tests carried out if they are eligible. (Author)

  20. Petroleum as a raw material resource for sustainable development

    International Nuclear Information System (INIS)

    Egorov, O.I.

    1996-01-01

    Author notes that for economic and social region development it is necessary has been created large petroleum chemical plants near by Atyrau city (initial raw material - Tengiz, Korolev and other petroleum deposits of this region) and Aktau (Mangistau and Bazuchin petroleum). Realization of projects for structure changes of petroleum and gas region demands a great investments. It is noted that growing scales of petroleum and gas resources mastering calls already a considerable environmental complications because of Caspian Sea's level marking rise

  1. Correcting length-frequency distributions for imperfect detection

    Science.gov (United States)

    Breton, André R.; Hawkins, John A.; Winkelman, Dana L.

    2013-01-01

    Sampling gear selects for specific sizes of fish, which may bias length-frequency distributions that are commonly used to assess population size structure, recruitment patterns, growth, and survival. To properly correct for sampling biases caused by gear and other sources, length-frequency distributions need to be corrected for imperfect detection. We describe a method for adjusting length-frequency distributions when capture and recapture probabilities are a function of fish length, temporal variation, and capture history. The method is applied to a study involving the removal of Smallmouth Bass Micropterus dolomieu by boat electrofishing from a 38.6-km reach on the Yampa River, Colorado. Smallmouth Bass longer than 100 mm were marked and released alive from 2005 to 2010 on one or more electrofishing passes and removed on all other passes from the population. Using the Huggins mark–recapture model, we detected a significant effect of fish total length, previous capture history (behavior), year, pass, year×behavior, and year×pass on capture and recapture probabilities. We demonstrate how to partition the Huggins estimate of abundance into length frequencies to correct for these effects. Uncorrected length frequencies of fish removed from Little Yampa Canyon were negatively biased in every year by as much as 88% relative to mark–recapture estimates for the smallest length-class in our analysis (100–110 mm). Bias declined but remained high even for adult length-classes (≥200 mm). The pattern of bias across length-classes was variable across years. The percentage of unadjusted counts that were below the lower 95% confidence interval from our adjusted length-frequency estimates were 95, 89, 84, 78, 81, and 92% from 2005 to 2010, respectively. Length-frequency distributions are widely used in fisheries science and management. Our simple method for correcting length-frequency estimates for imperfect detection could be widely applied when mark–recapture data

  2. MISCELLANEOUS BOTANICAL NOTES 2

    Directory of Open Access Journals (Sweden)

    A.J.G.H KOSTERMANS

    2014-01-01

    Full Text Available 1.   Durio  cupreus Ridley is considered to  represent a  distinct  species.2.   Durio wyatt-smithii Kosterm. is reported from Borneo.3.   Machilus nervosa Merr. represents Meliosma bontoeensis Merr.4.   Beilschmiedia brassii Allen represents Vavaea brassii (Allen Kosterm.5.   The author of the generic name Heritiera is Aiton.6.   Heritiera macrophylla (non Wall. Merr. is conspecific with H. ungus-tata Pierre.7.   Some specimens from N. Celebes, attributed formerly to H. sylvatica Merr., belong to H. arafurensis Kosterm.8.   Additional note on Heritiera littoralis Ait. and H. macrophylla Wall, ex Kurz.9.   Heritiera   montana   Kosterm.,   nov.   spec,   from   New   Guinea   and H. khidii Kosterm., nov. spec, from Northern Siam.10.   Additional note on Heritiera, novoguineensis Kosterm. and H. pereo-riacea Kosterm. and an undescribed species.11.   Heritiera acuminata Wall, ex Kurz represents a distinct species.12.   Heritiera  solomonensis  Kosterm.,  nov.  spec,  from the  Solomon  Isl.13.   A note on Firmiana bracteata A. DC.14.   Firmiana fulgens (Wall, ex King  Corner is based on a mixtum com-positum and has been the source of constant confusion. For the element, which occurs in Malaysia a new name is coined: F. malayana Kosterm. It does not occur in Tenasserim.15.   A revised bibliography of Firmiana colorata R. Br., F. pallens Stearn and F. malayana Kosterm. is presented.16.   Additional note on Firmiana hainanensis Kosterm.17.   Firmiana kerrii (Craib Kosterm., comb, nov., based on Sterculia kerrii Craib.18.   Additional specimens of Firmiana papuana Mildbr.19.   Cryptocarya hintonii Allen is referred to Primus as Primus hintonii (Allen  Kosterm.20.   Beilschmiedia wallichiana (G. Don   Kosterm., based on Sideroxylon wallichianum, G. Don, is described. Formerly it was relegated to Litsea by Kurz.21.   New species in Lauraceae: Beilschmiedia aborensis Kosterm., B

  3. Void growth to coalescence in a non-local material

    DEFF Research Database (Denmark)

    Niordson, Christian Frithiof

    2008-01-01

    of different material length parameters in a multi-parameter theory is studied, and it is shown that the important length parameter is the same as under purely hydrostatic loading. It is quantified how micron scale voids grow less rapidly than larger voids, and the implications of this in the overall strength...... of the material is emphasized. The size effect on the onset of coalescence is studied, and results for the void volume fraction and the strain at the onset of coalescence are presented. It is concluded that for cracked specimens not only the void volume fraction, but also the typical void size is of importance...... to the fracture strength of ductile materials....

  4. Computational simulation of laser heat processing of materials

    Science.gov (United States)

    Shankar, Vijaya; Gnanamuthu, Daniel

    1987-04-01

    A computational model simulating the laser heat treatment of AISI 4140 steel plates with a CW CO2 laser beam has been developed on the basis of the three-dimensional, time-dependent heat equation (subject to the appropriate boundary conditions). The solution method is based on Newton iteration applied to a triple-approximate factorized form of the equation. The method is implicit and time-accurate; the maintenance of time-accuracy in the numerical formulation is noted to be critical for the simulation of finite length workpieces with a finite laser beam dwell time.

  5. Effect of the Length of Traffic Flow Records on the Estimate of a Bridge Service Life

    Directory of Open Access Journals (Sweden)

    Krejsa Jan

    2016-12-01

    Full Text Available The service life of bridges is significantly affected by fatigue of used material induced by heavy vehicles. Therefore, precise determination of the vehicle weight is of crucial importance for the calculation of fatigue damage and the prediction of the bridge serviceability. This paper investigates accuracy of the determination of fatigue depending on the length of traffic flow recording. The presented data were obtained from the measurements carried out on a bridge of the Prague Highway Ring. The analysis reveals that the optimal length of traffic recording is about 30 days.

  6. Design and optimization analysis of dual material gate on DG-IMOS

    Science.gov (United States)

    Singh, Sarabdeep; Raman, Ashish; Kumar, Naveen

    2017-12-01

    An impact ionization MOSFET (IMOS) is evolved for overcoming the constraint of less than 60 mV/decade sub-threshold slope (SS) of conventional MOSFET at room temperature. In this work, first, the device performance of the p-type double gate impact ionization MOSFET (DG-IMOS) is optimized by adjusting the device design parameters. The adjusted parameters are ratio of gate and intrinsic length, gate dielectric thickness and gate work function. Secondly, the DMG (dual material gate) DG-IMOS is proposed and investigated. This DMG DG-IMOS is further optimized to obtain the best possible performance parameters. Simulation results reveal that DMG DG-IMOS when compared to DG-IMOS, shows better I ON, I ON/I OFF ratio, and RF parameters. Results show that by properly tuning the lengths of two materials at a ratio of 1.5 in DMG DG-IMOS, optimized performance is achieved including I ON/I OFF ratio of 2.87 × 109 A/μm with I ON as 11.87 × 10-4 A/μm and transconductance of 1.06 × 10-3 S/μm. It is analyzed that length of drain side material should be greater than the length of source side material to attain the higher transconductance in DMG DG-IMOS.

  7. A method for estimating age of medieval sub-adults from infancy to adulthood based on long bone length

    DEFF Research Database (Denmark)

    Primeau, Charlotte; Friis, Laila Saidane; Sejrsen, Birgitte

    2016-01-01

    OBJECTIVES: To develop a series of regression equations for estimating age from length of long bones for archaeological sub-adults when aging from dental development cannot be performed. Further, to compare derived ages when using these regression equations, and two other methods. MATERIAL AND ME...... as later than the medieval period, although this would require further testing. The quadratic equations are suggested to yield more accurate ages then using simply linear regression equations. Am J Phys Anthropol, 2015. © 2015 Wiley Periodicals, Inc.......OBJECTIVES: To develop a series of regression equations for estimating age from length of long bones for archaeological sub-adults when aging from dental development cannot be performed. Further, to compare derived ages when using these regression equations, and two other methods. MATERIAL...... AND METHODS: A total of 183 skeletal sub-adults from the Danish medieval period, were aged from radiographic images. Linear regression formulae were then produced for individual bones. Age was then estimated from the femur length using three different methods: equations developed in this study, data based...

  8. Laparotomy operative note template constructed through a modified Delphi method.

    Science.gov (United States)

    Moore, Lolonya; Churley-Strom, Ruth; Singal, Bonita; O'Leary, Sharon

    2009-05-01

    An operative note is indispensable to physician documentation and decision-making; however, there are no accepted standards for operative note content. Our aim was to use a modified Delphi consensus-building method to construct a uniform operative note template for laparotomy. Using Joint Commission on Accreditation of Healthcare Organizations requirements, literature review, and feedback from 15 medical malpractice defense attorneys, we compiled a draft operative note template of 31 elements. We surveyed 37 Association of Professor of Gynecology and Obstetrics/Solvay scholars asking for their input on inclusion of each item as essential content of the operative note. Two iterations of the survey were required to reach a predetermined 75% level of consensus. Nine elements were eliminated from the template: 6 original and 3 expert-suggested elements. We provide an operative note template that was compiled through a Delphi process.

  9. Nanophotonic Modulator with Bismuth Ferrite as Low-loss Switchable Material

    DEFF Research Database (Denmark)

    Babicheva, Viktoriia; Zhukovsky, Sergei; Lavrinenko, Andrei

    2015-01-01

    We propose a nanophotonic waveguide modulator with bismuth ferrite as a tunable material. Due to near-zero losses in bismuth ferrite, modulation with up to 20 dB/μm extinction ratio and 12 μm propagation length is achieved.......We propose a nanophotonic waveguide modulator with bismuth ferrite as a tunable material. Due to near-zero losses in bismuth ferrite, modulation with up to 20 dB/μm extinction ratio and 12 μm propagation length is achieved....

  10. Improving operation notes to meet British Orthopaedic Association guidelines.

    Science.gov (United States)

    Morgan, David; Fisher, Noel; Ahmad, Aman; Alam, Fazle

    2009-04-01

    Operation notes are an important part of medical records for clinical, academic and medicolegal reasons. This study audited the quality of operative note keeping for total knee replacements against the standards set by the British Orthopaedic Association (BOA). A prospective review of all patients undergoing total knee replacement at a district general hospital over 8 months. Data recorded were compared with those required by the BOA good-practice guidelines. Change in practice was implemented and the audit cycle completed. Data were statistically analysed. A total of 129 operation notes were reviewed. There was a significant improvement in the mean number of data points recorded from 9.6 to 13.1. The least well recorded data were diagnosis, description of findings, alignment and postoperative flexion range. All had a significant improvement except description of findings. The operating surgeon writing the note improved from 56% to 67%. Detailed postoperative instructions also improved in quality. Surgeon education and the use of a checklist produce better quality total knee replacement operation notes in line with BOA guidelines. Further improvements may be made by making the data points part of the operation note itself.

  11. THz Wireless Transmission Systems Based on Photonic Generation of Highly Pure Beat-Notes

    DEFF Research Database (Denmark)

    Jia, Shi; Yu, Xianbin; Hu, Hao

    2016-01-01

    In this paper, a terahertz (THz) wireless communication system at 400 GHz with various modulation formats [on–off keying (OOK), quadrature phase-shift keying (QPSK), 16-quadrature amplitude modulation (16-QAM), and 32-quadrature amplitude modulation (32-QAM)] is experimentally demonstrated based...... noise of photonically generated THz beat-notes when phase correlation of two optical comb tones is damaged due to their path-length difference. In addition, we demonstrate THz wireless transmission of various modulation formats, including OOK, QPSK, 16-QAM, and 32-QAM at beyond 10 Gb/s in such a system......, and the measured bit error rate (BER) performance for all the signals after 0.5 m free-space delivery is below the hard decision forward error correction threshold of 3.8 × 10–3. Furthermore, the influence of THz carrier purity on the system performance is experimentally analyzed with respect to the BER of the THz...

  12. QNOTE: an instrument for measuring the quality of EHR clinical notes.

    Science.gov (United States)

    Burke, Harry B; Hoang, Albert; Becher, Dorothy; Fontelo, Paul; Liu, Fang; Stephens, Mark; Pangaro, Louis N; Sessums, Laura L; O'Malley, Patrick; Baxi, Nancy S; Bunt, Christopher W; Capaldi, Vincent F; Chen, Julie M; Cooper, Barbara A; Djuric, David A; Hodge, Joshua A; Kane, Shawn; Magee, Charles; Makary, Zizette R; Mallory, Renee M; Miller, Thomas; Saperstein, Adam; Servey, Jessica; Gimbel, Ronald W

    2014-01-01

    The outpatient clinical note documents the clinician's information collection, problem assessment, and patient management, yet there is currently no validated instrument to measure the quality of the electronic clinical note. This study evaluated the validity of the QNOTE instrument, which assesses 12 elements in the clinical note, for measuring the quality of clinical notes. It also compared its performance with a global instrument that assesses the clinical note as a whole. Retrospective multicenter blinded study of the clinical notes of 100 outpatients with type 2 diabetes mellitus who had been seen in clinic on at least three occasions. The 300 notes were rated by eight general internal medicine and eight family medicine practicing physicians. The QNOTE instrument scored the quality of the note as the sum of a set of 12 note element scores, and its inter-rater agreement was measured by the intraclass correlation coefficient. The Global instrument scored the note in its entirety, and its inter-rater agreement was measured by the Fleiss κ. The overall QNOTE inter-rater agreement was 0.82 (CI 0.80 to 0.84), and its note quality score was 65 (CI 64 to 66). The Global inter-rater agreement was 0.24 (CI 0.19 to 0.29), and its note quality score was 52 (CI 49 to 55). The QNOTE quality scores were consistent, and the overall QNOTE score was significantly higher than the overall Global score (p=0.04). We found the QNOTE to be a valid instrument for evaluating the quality of electronic clinical notes, and its performance was superior to that of the Global instrument. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  13. Fragment Length of Circulating Tumor DNA.

    Science.gov (United States)

    Underhill, Hunter R; Kitzman, Jacob O; Hellwig, Sabine; Welker, Noah C; Daza, Riza; Baker, Daniel N; Gligorich, Keith M; Rostomily, Robert C; Bronner, Mary P; Shendure, Jay

    2016-07-01

    Malignant tumors shed DNA into the circulation. The transient half-life of circulating tumor DNA (ctDNA) may afford the opportunity to diagnose, monitor recurrence, and evaluate response to therapy solely through a non-invasive blood draw. However, detecting ctDNA against the normally occurring background of cell-free DNA derived from healthy cells has proven challenging, particularly in non-metastatic solid tumors. In this study, distinct differences in fragment length size between ctDNAs and normal cell-free DNA are defined. Human ctDNA in rat plasma derived from human glioblastoma multiforme stem-like cells in the rat brain and human hepatocellular carcinoma in the rat flank were found to have a shorter principal fragment length than the background rat cell-free DNA (134-144 bp vs. 167 bp, respectively). Subsequently, a similar shift in the fragment length of ctDNA in humans with melanoma and lung cancer was identified compared to healthy controls. Comparison of fragment lengths from cell-free DNA between a melanoma patient and healthy controls found that the BRAF V600E mutant allele occurred more commonly at a shorter fragment length than the fragment length of the wild-type allele (132-145 bp vs. 165 bp, respectively). Moreover, size-selecting for shorter cell-free DNA fragment lengths substantially increased the EGFR T790M mutant allele frequency in human lung cancer. These findings provide compelling evidence that experimental or bioinformatic isolation of a specific subset of fragment lengths from cell-free DNA may improve detection of ctDNA.

  14. Spectral sensitization of TiO2 by new hemicyanine dyes in dye solar cell yielding enhanced photovoltage: Probing chain length effect on performance

    International Nuclear Information System (INIS)

    Fadadu, Kishan B.; Soni, Saurabh S.

    2013-01-01

    Graphical abstract: New hemicyanine dyes based on indolenine moiety were utilized as light harvesting materials in dye sensitized solar cell. Chain lengths of the molecules were varied in order to study its effect of chain length on the performance of DSSC. Electron transfer kinetic of the solar cell was studied and it was found that the chain length changes the electron transfer kinetic. We have achieved remarkable photovoltage and overall performance of DSSC. Highlights: ► New hemicyanine dyes based on indolenine moiety were utilized as light harvesting materials in dye sensitized solar cell. ► Chain lengths of the molecules were varied in order to study its effect of chain length on the performance of DSSC. ► Electron transfer kinetic of the solar cell was studied and it was found that the chain length changes the electron transfer kinetic. -- Abstract: New hemicyanine dyes having indole nucleus with different alkyl chain length were synthesized and characterized using 1 H NMR and mass spectroscopy. These dyes were used to sensitize the TiO 2 film in dye sensitized solar cell. Nanocrystalline dye solar cells were fabricated and characterized using various electrochemical techniques. It has been found that the alkyl chain length present in the dye molecules greatly affects the overall performance of dye solar cell. Molecules having longer alkyl chain are having better sensitizers which enhance V oc to significant extent. Chain length dependent performance was further investigated using Tafel polarization and impedance method. Hemicyanine dye having hexyl chain has outperformed by attaining 2.9% solar to electricity conversion efficiency

  15. Criteria for accurate determination of the magnon relaxation length from the nonlocal spin Seebeck effect

    NARCIS (Netherlands)

    Shan, Juan; Cornelissen, Ludo Johannes; Liu, Jing; Ben Youssef, J.; Liang, Lei; van Wees, Bart

    2017-01-01

    The nonlocal transport of thermally generated magnons not only unveils the underlying mechanism of the spin Seebeck effect, but also allows for the extraction of the magnon relaxation length (λm) in a magnetic material, the average distance over which thermal magnons can propagate. In this study, we

  16. Import/export Service of Radioactive Material

    CERN Multimedia

    2004-01-01

    Please note that the Import/Export service of radioactive material (24/E-024) is open from Monday to Friday, 8:00 to 11:00. No request will be treated the afternoon. Web site: http://cern.ch/service-rp-shipping/ Tel.: 73171 E-mail: service-rp-shipping@cern.ch Radioactive Sources Service Please note that the radioactive sources service (24/E-024) is open from Monday to Friday, 8:00 to 11:00. No request will be treated the afternoon. Moreover, the service being reduced, transports between Swiss and French sites (and vice versa) will now be achieved by internal transport. Web site : http://cern.ch/service-rp-sources Tel.: 73171 E-mail: service-rp-sources@cern.ch

  17. Import/export Service of Radioactive Material

    CERN Multimedia

    2004-01-01

    Please note that the Import/Export service of radioactive material (24/E-024) is open from Monday to Friday, 8:00 to 11:00. No request will be treated the afternoon. Web site: http://cern.ch/service-rp-shipping/ Tel.: 73171 E-mail: service-rp-shipping@cern.ch Radioactive Sources Service Please note that the radioactive sources service (24/E-024) is open from Monday to Friday, 8:00 to 11:00. No request will be treated the afternoon. Moreover, the service being reduced transports between Swiss and French sites (and vice versa) will now be achieved by internal transport. Web site : http://cern.ch/service-radioactive-sources/ Tel.: 73171 E-mail: service-rp-shipping@cern.ch

  18. Evaluation of the Survival Rate and Bone Loss of Implants with Various Lengths

    Directory of Open Access Journals (Sweden)

    AR. Rokn

    2006-12-01

    Full Text Available Statement of Problem: The replacement of missing teeth with implant-associated restorations has become a widely used treatment modality in recent years. The length of dental implants may be a critical factor in achieving and maintaining osseointegration.Purpose: The aim of this study was to evaluate the survival rate and bone loss of dental implants with different lengthsMaterials and Methods: A retrospective cohort study was performed on 60 ITI-system implants, evenly distributed into three groups including 8, 10 and 12 mm high implants in the posterior segments of both jaws. Demographic information, oral hygiene,cigarette smoking, implant length, duration of implant placement (at least 24 months,bleeding on probing index and pocket probing depth were recorded for all participants.Bone loss was calculated using pre- and post-operative panoramic radiographs.Results: The mean rate of bone loss was different among the three groups and were found to be 0.21 (0.45, 0.3 (0.41 and 0.43 (0.55 mm in the 8, 10, and 12 mm high implants, respectively. Neither mean bone loss nor bleeding on probing index showed significant differences with implant length. A significant correlation was found between implant length and pocket probing depth (P<0.0001.Conclusion: The results of this study suggest that both short (8 mm high and long (10 or 12 mm high implants may be used with nearly equal success rates in the posterior segments of the jaws.

  19. Thermal significance of fission-track length distributions

    International Nuclear Information System (INIS)

    Crowley, K.D.

    1985-01-01

    The semi-analytical solution of an equation describing the production and shortening of fission tracks in apatite suggests that certain thermal histories have unique length-distribution 'signatures'. Isothermal-heating histories should be characterized by flattened, length-shortened distributions; step-heating histories should be characterized by bimodal track length distributions; and linear-cooling histories should be characterized by negatively skewed, length-shortened distributions. The model formulated here to investigate track length distributions can be used to constrain the thermal histories of natural samples for which unbiased track length data are available - provided that the geologic history of the system of interest can be used to partially constrain one of the unknowns in the model equations, time or temperature. (author)

  20. Investigation of the extraction of short diffusion lengths from simulated electron-beam induced current

    Energy Technology Data Exchange (ETDEWEB)

    Wee, D.; Parish, G.; Nener, B. [Microelectronics Research Group, The University of Western Australia, 35 Stirling Highway, 6009 Crawley (Perth) (Australia)

    2010-10-15

    This paper reports on the investigations via 2-D simulation into the accuracy of diffusion length extraction from scanning electron-beam induced current measurements when the diffusion length, L is very short. L is extracted by using the direct method proposed by Chan et al.[1] and later refined by Kurniawan and Ong[2] to take finite junction depth into account. The 2-D simulations were undertaken using Synopsys {sup registered} Sentaurus TCAD and a realistic electron-hole pair generation volume was created using CASINO v2.42[3], a Monte Carlo Scanning Electron Microscope interaction simulation software, and imported into Sentaurus. The voltage and diameter of the electron beam and diffusion length and surface recombination velocity of the semiconductor materials were varied in the simulations to determine the errors in the diffusion length extracted from the EBIC signals as a function of these parameters. The results of the simulation show that the accuracy of the method proposed in[1] is reasonably accurate and that the beam voltage and spot size do not have significant effects on the accuracy (copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  1. Investigation of the extraction of short diffusion lengths from simulated electron-beam induced current

    International Nuclear Information System (INIS)

    Wee, D.; Parish, G.; Nener, B.

    2010-01-01

    This paper reports on the investigations via 2-D simulation into the accuracy of diffusion length extraction from scanning electron-beam induced current measurements when the diffusion length, L is very short. L is extracted by using the direct method proposed by Chan et al.[1] and later refined by Kurniawan and Ong[2] to take finite junction depth into account. The 2-D simulations were undertaken using Synopsys registered Sentaurus TCAD and a realistic electron-hole pair generation volume was created using CASINO v2.42[3], a Monte Carlo Scanning Electron Microscope interaction simulation software, and imported into Sentaurus. The voltage and diameter of the electron beam and diffusion length and surface recombination velocity of the semiconductor materials were varied in the simulations to determine the errors in the diffusion length extracted from the EBIC signals as a function of these parameters. The results of the simulation show that the accuracy of the method proposed in[1] is reasonably accurate and that the beam voltage and spot size do not have significant effects on the accuracy (copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  2. Interpreters' notes. On the choice of language

    DEFF Research Database (Denmark)

    Dam, Helle Vrønning

    2004-01-01

    This paper reports on a small-scale empirical study on note-taking in consecutive interpreting. As data, the study draws on the notes produced by four subjects while interpreting one Spanish source text consecutively into Danish, on the one hand, and one Danish source text into Spanish, on the ot...... in the interpreting task, i.e. whether it functions as the source or the target language. Drawing on the concept of processing capacity and the Effort Model of consecutive, a tentative explanation of these findings is suggested......., on the other. The aim of the study is to explore what governs conference interpreters' choice of language for their notes. The categories traditionally used to discuss, describe and explain this choice are those of 'source language' and 'target language', and these categories are therefore subject...... to particular scrutiny here. However, somewhat surprisingly, the results of the analyses indicate that the choice of language in note-taking is governed mainly by the status of the language in the interpreters' language combination, i.e. whether it is an A- or a B-language, and much less by its status...

  3. Screening length in dusty plasma crystals

    International Nuclear Information System (INIS)

    Nikolaev, V S; Timofeev, A V

    2016-01-01

    Particles interaction and value of the screening length in dusty plasma systems are of great interest in dusty plasma area. Three inter-particle potentials (Debye potential, Gurevich potential and interaction potential in the weakly collisional regime) are used to solve equilibrium equations for two dusty particles suspended in a parabolic trap. The inter-particle distance dependence on screening length, trap parameter and particle charge is obtained. The functional form of inter-particle distance dependence on ion temperature is investigated and compared with experimental data at 200-300 K in order to test used potentials applicability to dusty plasma systems at room temperatures. The preference is given to the Yukawa-type potential including effective values of particle charge and screening length. The estimated effective value of the screening length is 5-15 times larger than the Debye length. (paper)

  4. Trends in the Use of Supplementary Materials in Environmental Science Journals

    Science.gov (United States)

    Kenyon, Jeremy; Sprague, Nancy R.

    2014-01-01

    Our research examined the use of supplementary materials in six environmental science disciplines: atmospheric sciences, biology, fisheries, forestry, geology, and plant sciences. Ten key journals were selected from each of these disciplines and the number of supplementary materials, such as data files or videos, in each issue was noted over a…

  5. Impact of spherical inclusion mean chord length and radius distribution on three-dimensional binary stochastic medium particle transport

    International Nuclear Information System (INIS)

    Brantley, Patrick S.; Martos, Jenny N.

    2011-01-01

    We describe a parallel benchmark procedure and numerical results for a three-dimensional binary stochastic medium particle transport benchmark problem. The binary stochastic medium is composed of optically thick spherical inclusions distributed in an optically thin background matrix material. We investigate three sphere mean chord lengths, three distributions for the sphere radii (constant, uniform, and exponential), and six sphere volume fractions ranging from 0.05 to 0.3. For each sampled independent material realization, we solve the associated transport problem using the Mercury Monte Carlo particle transport code. We compare the ensemble-averaged benchmark fiducial tallies of reflection from and transmission through the spatial domain as well as absorption in the spherical inclusion and background matrix materials. For the parameter values investigated, we find a significant dependence of the ensemble-averaged fiducial tallies on both sphere mean chord length and sphere volume fraction, with the most dramatic variation occurring for the transmission through the spatial domain. We find a weaker dependence of most benchmark tally quantities on the distribution describing the sphere radii, provided the sphere mean chord length used is the same in the different distributions. The exponential distribution produces larger differences from the constant distribution than the uniform distribution produces. The transmission through the spatial domain does exhibit a significant variation when an exponential radius distribution is used. (author)

  6. Zero-point length from string fluctuations

    International Nuclear Information System (INIS)

    Fontanini, Michele; Spallucci, Euro; Padmanabhan, T.

    2006-01-01

    One of the leading candidates for quantum gravity, viz. string theory, has the following features incorporated in it. (i) The full spacetime is higher-dimensional, with (possibly) compact extra-dimensions; (ii) there is a natural minimal length below which the concept of continuum spacetime needs to be modified by some deeper concept. On the other hand, the existence of a minimal length (zero-point length) in four-dimensional spacetime, with obvious implications as UV regulator, has been often conjectured as a natural aftermath of any correct quantum theory of gravity. We show that one can incorporate the apparently unrelated pieces of information-zero-point length, extra-dimensions, string T-duality-in a consistent framework. This is done in terms of a modified Kaluza-Klein theory that interpolates between (high-energy) string theory and (low-energy) quantum field theory. In this model, the zero-point length in four dimensions is a 'virtual memory' of the length scale of compact extra-dimensions. Such a scale turns out to be determined by T-duality inherited from the underlying fundamental string theory. From a low energy perspective short distance infinities are cutoff by a minimal length which is proportional to the square root of the string slope, i.e., α ' . Thus, we bridge the gap between the string theory domain and the low energy arena of point-particle quantum field theory

  7. The Effects of Note-Taking Skills Instruction on Elementary Students' Reading

    Science.gov (United States)

    Chang, Wan-Chen; Ku, Yu-Min

    2015-01-01

    The authors investigated the effects of a 5-week note-taking skills instructional program on note-taking and reading comprehension performance of elementary students. The participants included 349 fourth-grade students from 2 elementary schools in Taiwan. The Note-Taking Instruction group received approximately 40 min of note-taking skills…

  8. Volar plating for distal radius fractures--do not trust the image intensifier when judging distal subchondral screw length.

    Science.gov (United States)

    Park, Derek H; Goldie, Boyd S

    2012-09-01

    The use of the volar plate to treat distal radius fractures is increasing but despite the theoretical advantages of a volar approach there have been reports of extensor tendon ruptures due to prominent screw tips protruding past the dorsal cortex. The valley in the intermediate column between Lister tubercle and the sigmoid notch of the distal radius makes it difficult to rely on fluoroscopy to judge screw length. Our aim was to quantify the dimensions of this valley and to demonstrate the danger of relying on intraoperative image intensification fluoroscopy to determine lengths of distal screws. We measured the depth of this valley in the intermediate column of the distal radius in 33 patients with computed tomographic (9 patients) or magnetic resonance image (24 patients) scans of the wrist. There was a consistent valley in all images examined [average 1.8 mm (95% confidence interval, 1.6-2.0 mm)]. Thirty-nine percent of wrists had a valley depth of at least 2 mm. Standard lateral views or rotation of the forearm to obtain oblique views does not identify prominent screw tips; and whatever the rotation of the forearm, screw tips protruding beyond dorsal cortex may look as if it is within the bone when in fact it is out. When drilling we suggest noting the depth at which the drill bit just penetrates dorsal cortex and routinely downsize the distal screw length by 2 mm. We caution against relying on flourosocopy when judging the length of the distal subchondral screws.

  9. The future of NOTES from the conservative point of view.

    Science.gov (United States)

    Kano, Nobuyasu

    2009-01-01

    Recently, the unfamiliar term "natural orifice transluminal endoscopic surgery (NOTES)" appeared in my field. Actually, I am hesitant to accept this technique in my surgical practice. In this paper, I will review some references and try to establish my position toward NOTES. The author has been skeptical and ironical about the clinical potentiality of NOTES since hearing the presentation about NOTES for the first time. I have been concerned about making a puncture in the gastrointestinal tract as an old surgeon who believes that intestinal injury must not occur during surgery. However, recent advances in the research of NOTES are changing my stubborn belief. What I have to do is to avoid interrupting or disturbing young surgeons' challenges to develop NOTES. I remember that some senior surgeons were against us when we started laparoscopic surgery around 1990. Senior surgeons and physicians must be generous, considerate, helpful and supportive to our followers. I have been enthusiastic about the development and spread of laparoscopic surgery since 1987 and have been doing various surgical procedures myself, including those involving the biliary tract, pancreas, spleen, upper and lower gastrointestinal tract, adrenal, kidney and gynecologic organs. Recently, the unfamiliar term "NOTES" appeared in my field. Actually, I am hesitant to accept this technique in my surgical practice. In this paper I will review some references and try to establish my position toward NOTES.

  10. Structure-guided investigation of lipopolysaccharide O-antigen chain length regulators reveals regions critical for modal length control.

    Science.gov (United States)

    Kalynych, Sergei; Ruan, Xiang; Valvano, Miguel A; Cygler, Miroslaw

    2011-08-01

    The O-antigen component of the lipopolysaccharide (LPS) represents a population of polysaccharide molecules with nonrandom (modal) chain length distribution. The number of the repeat O units in each individual O-antigen polymer depends on the Wzz chain length regulator, an inner membrane protein belonging to the polysaccharide copolymerase (PCP) family. Different Wzz proteins confer vastly different ranges of modal lengths (4 to >100 repeat units), despite having remarkably conserved structural folds. The molecular mechanism responsible for the selective preference for a certain number of O units is unknown. Guided by the three-dimensional structures of PCPs, we constructed a panel of chimeric molecules containing parts of two closely related Wzz proteins from Salmonella enterica and Shigella flexneri which confer different O-antigen chain length distributions. Analysis of the O-antigen length distribution imparted by each chimera revealed the region spanning amino acids 67 to 95 (region 67 to 95), region 200 to 255, and region 269 to 274 as primarily affecting the length distribution. We also showed that there is no synergy between these regions. In particular, region 269 to 274 also influenced chain length distribution mediated by two distantly related PCPs, WzzB and FepE. Furthermore, from the 3 regions uncovered in this study, region 269 to 274 appeared to be critical for the stability of the oligomeric form of Wzz, as determined by cross-linking experiments. Together, our data suggest that chain length determination depends on regions that likely contribute to stabilize a supramolecular complex.

  11. Executive functions in becoming writing readers and reading writers: note taking and report writing in third and fifth graders.

    Science.gov (United States)

    Altemeier, Leah; Jones, Janine; Abbott, Robert D; Berninger, Virginia W

    2006-01-01

    Results are reported for a study of 2 separate processes of report writing-taking notes while reading source material and composing a report from those notes-and related individual differences in executive functions involved in integrating reading and writing during these writing activities. Third graders (n = 122) and 5th graders (n = 106; overall, 127 girls and 114 boys) completed two reading-writing tasks-read paragraph (mock science text)-write notes and use notes to generate written report, a reading comprehension test, a written expression test, four tests of executive functions (inhibition, verbal fluency, planning, switching attention), and a working memory test. For the read-take notes task, the same combination of variables was best (explained the most variance and each variable added unique variance) for 3rd graders and 5th graders: Wechsler Individual Achievement Test-Second Edition (WIAT-II) Reading Comprehension, Process Assessment of the Learner Test for Reading and Writing (PAL) Copy Task B, WIAT-II Written Expression, and Delis-Kaplan Executive Function System (D-KEFS) Inhibition. For the use notes to write report task, the best combinations of variables depended on grade level: For 3rd graders, WIAT-II Reading Comprehension, WIAT-II Written Expression, D-KEFS Verbal Fluency, and Tower of Hanoi; for 5th graders, WIAT-II Reading Comprehension, D-KEFS Verbal Fluency, WIAT-II Written Expression, and PAL Alphabet Task. These results add to prior research findings that executive functions contribute to the writing development of elementary-grade students and additionally support the hypothesis that executive functions play a role in developing reading-writing connections.

  12. An equal force theory for network models of soft materials with arbitrary molecular weight distribution

    Science.gov (United States)

    Verron, E.; Gros, A.

    2017-09-01

    Most network models for soft materials, e.g. elastomers and gels, are dedicated to idealized materials: all chains admit the same number of Kuhn segments. Nevertheless, such standard models are not appropriate for materials involving multiple networks, and some specific constitutive equations devoted to these materials have been derived in the last few years. In nearly all cases, idealized networks of different chain lengths are assembled following an equal strain assumption; only few papers adopt an equal stress assumption, although some authors argue that such hypothesis would reflect the equilibrium of the different networks in contact. In this work, a full-network model with an arbitrary chain length distribution is derived by considering that chains of different lengths satisfy the equal force assumption in each direction of the unit sphere. The derivation is restricted to non-Gaussian freely jointed chains and to affine deformation of the sphere. Firstly, after a proper definition of the undeformed configuration of the network, we demonstrate that the equal force assumption leads to the equality of a normalized stretch in chains of different lengths. Secondly, we establish that the network with chain length distribution behaves as an idealized full-network of which both chain length and density of are provided by the chain length distribution. This approach is finally illustrated with two examples: the derivation of a new expression for the Young modulus of bimodal interpenetrated polymer networks, and the prediction of the change in fluorescence during deformation of mechanochemically responsive elastomers.

  13. Quantitative analysis of length-diameter distribution and cross-sectional properties of fibers from three-dimensional tomographic images

    DEFF Research Database (Denmark)

    Miettinen, Arttu; Joffe, Roberts; Madsen, Bo

    2013-01-01

    obtained from optical microscopy of polished cross-sections of a composite. This approach gives accurate yet local results, but a rather large number of optical images have to be processed to achieve a representative description of the morphology of the material. In this work a fully automatic algorithm......A number of rule-of-mixture micromechanical models have been successfully used to predict the mechanical properties of short fiber composites. However, in order to obtain accurate predictions, a detailed description of the internal structure of the material is required. This information is often...... for estimating the length-diameter distribution of solid or hollow fibers, utilizing three-dimensional X-ray tomographic images, is presented. The method is based on a granulometric approach for fiber length distribution measurement, combined with a novel algorithm that relates cross-sectional fiber properties...

  14. Diet, nutrition and telomere length.

    Science.gov (United States)

    Paul, Ligi

    2011-10-01

    The ends of human chromosomes are protected by DNA-protein complexes termed telomeres, which prevent the chromosomes from fusing with each other and from being recognized as a double-strand break by DNA repair proteins. Due to the incomplete replication of linear chromosomes by DNA polymerase, telomeric DNA shortens with repeated cell divisions until the telomeres reach a critical length, at which point the cells enter senescence. Telomere length is an indicator of biological aging, and dysfunction of telomeres is linked to age-related pathologies like cardiovascular disease, Parkinson disease, Alzheimer disease and cancer. Telomere length has been shown to be positively associated with nutritional status in human and animal studies. Various nutrients influence telomere length potentially through mechanisms that reflect their role in cellular functions including inflammation, oxidative stress, DNA integrity, DNA methylation and activity of telomerase, the enzyme that adds the telomeric repeats to the ends of the newly synthesized DNA. Copyright © 2011 Elsevier Inc. All rights reserved.

  15. Extended fuel cycle length

    International Nuclear Information System (INIS)

    Bruyere, M.; Vallee, A.; Collette, C.

    1986-09-01

    Extended fuel cycle length and burnup are currently offered by Framatome and Fragema in order to satisfy the needs of the utilities in terms of fuel cycle cost and of overall systems cost optimization. We intend to point out the consequences of an increased fuel cycle length and burnup on reactor safety, in order to determine whether the bounding safety analyses presented in the Safety Analysis Report are applicable and to evaluate the effect on plant licensing. This paper presents the results of this examination. The first part indicates the consequences of increased fuel cycle length and burnup on the nuclear data used in the bounding accident analyses. In the second part of this paper, the required safety reanalyses are presented and the impact on the safety margins of different fuel management strategies is examined. In addition, systems modifications which can be required are indicated

  16. Clinical Note Creation, Binning, and Artificial Intelligence.

    Science.gov (United States)

    Deliberato, Rodrigo Octávio; Celi, Leo Anthony; Stone, David J

    2017-08-03

    The creation of medical notes in software applications poses an intrinsic problem in workflow as the technology inherently intervenes in the processes of collecting and assembling information, as well as the production of a data-driven note that meets both individual and healthcare system requirements. In addition, the note writing applications in currently available electronic health records (EHRs) do not function to support decision making to any substantial degree. We suggest that artificial intelligence (AI) could be utilized to facilitate the workflows of the data collection and assembly processes, as well as to support the development of personalized, yet data-driven assessments and plans. ©Rodrigo Octávio Deliberato, Leo Anthony Celi, David J Stone. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 03.08.2017.

  17. 7 CFR 3550.208 - Reamortization using promissory note interest rate.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Reamortization using promissory note interest rate... § 3550.208 Reamortization using promissory note interest rate. Reamortization using the promissory note interest rate may be authorized when RHS determines that reamortization is required to enable the borrower...

  18. In vitro comparison of working length determination using three different electronic apex locators

    Directory of Open Access Journals (Sweden)

    Alper Kuştarci

    2014-01-01

    Full Text Available Background: The aim of this study was to compare the accuracy of the apex-locating functions of DentaPort ZX, Raypex 5 and Endo Master electronic apex locators (EALs in vitro. Materials and Methods: Thirty extracted human single-rooted teeth with mature apices were used for the study. The real working length (RWL was established by subtracting 0.5 mm from the actual root canal length. All teeth were mounted in an alginate model that was especially developed to test the EALs and the teeth were then measured with each EAL. The results were compared with the corresponding RWL, which was subtracted from the electronically determined distance. Data were analyzed using a paired-samples t-test, a Chi-square test and a repeated measure analysis of variance evaluation at the 0.05 level of significance. Results: Statistical analysis showed that no significant difference was found among all EALs (P > 0.05. Conclusion: The accuracy of the EALs was evaluated and all of the devices showed an acceptable determination of electronic working length between the ranges of ±0.5 mm.

  19. Shorter dialysis session length was not associated with lower mental health and physical functioning in elderly hemodialysis patients: Results from the Japan Dialysis Outcome and Practice Patterns Study (J-DOPPS.

    Directory of Open Access Journals (Sweden)

    Masashi Kitagawa

    Full Text Available Health-related quality of life (HRQOL is often prioritized over long-term survival in elderly patients. Although a longer dialysis session length (DSL has been shown to reduce mortality, its effects on improving the HRQOL are unknown.Using data from the Japan Dialysis Outcomes and Practice Patterns Study (J-DOPPS, patients aged ≥ 65 years on maintenance hemodialysis were enrolled. DSL was categorized as short (240 minutes. The primary outcomes were changes in mental health (ΔMH and physical functioning (ΔPF scores assessed using the Japanese version of SF-12, in one year. The differences in the ΔMH and ΔPF among the three groups were assessed via regression (beta coefficients derived using a linear regression model.Of 1,187 patients at baseline, 319 (26.9% had a short length, 686 (57.8% a medium length, and 182 (15.3% a long length. We assessed the ΔMH data from 793 patients and the ΔPF data from 738. No significant differences in the ΔMH were noted for the short or long groups compared with the medium group (score difference: 0.26, 95% confidence interval [CI]: -4.17 to 4.69 for short; score difference: -1.15, 95% CI: -6.17 to 3.86 for long. Similarly, no significant differences were noted for these groups versus the medium group in ΔPF either (score difference: -1.43, 95% CI: -6.73 to 3.87 for short; score difference: -1.71, 95% CI: -7.63 to 4.22 for long.A shorter DSL might have no adverse effects on MH or PF for elderly patients.

  20. Influences of the shielding cylinder on the length of radio-frequency cold atmospheric plasma jets

    Science.gov (United States)

    Li, He-Ping; Li, Jing; Zhang, Xiao-Fei; Guo, Heng; Chen, Jian; Department of Engineering Physics Team

    2017-10-01

    Cold atmospheric plasma jets driven by a radio frequency power supply contain abundant species and complex chemical reactions, which have wide applications in the fields of materials processing and modifications, food engineering, bio-medical science, etc. Our previous experiments have shown that the total length of a radio-frequency cold atmospheric plasma (RF-CAP) jet can exceed 1 meter with the shielding of a quartz tube. However, the shielding mechanisms of the solid cylinder has not been studied systematically. In this study, a two-dimensional, quasi-steady fluid model is used to investigate the influences of the shielding tube on the length of the RF-CAP jets under different conditions. The simulation results show that the total jet length grows monotonously; while simultaneously, the jet length out of the tube shows a non-monotonic variation trend, with the increase of the tube length, which is in good agreement with the experimental observations. The shielding mechanisms of the solid cylinder on the RF-CAP jet is also discussed in detail based on the modeling results. This work was supported by the National Natural Science Foundation of China (11475103, 21627812), the National Key Research and Development Program of China (2016YFD0102106) and Tsinghua University Initiative Scientific Program (20161080108).

  1. The concept of disclosure in the notes to financial statements

    Directory of Open Access Journals (Sweden)

    A.V. Ozeran

    2015-12-01

    Full Text Available The notes to Financial Statements are one of the most powerful sources of information for management decisions concerning a business entity. The tendency to overload informative notes causes rethinking of their role and content. The aim of the study is to discuss a number of ideas that set the requirements for disclosure in the notes to financial statements in order to prevent duplication of information in financial reporting as a whole and eliminate irrelevant disclosure to achieve clarity, consistency and effectiveness of the information contained in the notes. Based on the proposed clarified definition of «the notes to financial statements», we concluded that the notes should: a provide details and explanations of primary financial statements; b apply only to transactions and events existing at the reporting date; c focus on the needs of specific users and reflect reporting information specific to each entity. The development of the paper concepts will help strengthen the usefulness of company financial statements and increase their transparency.

  2. Alcune Note di Analisi Matematica

    OpenAIRE

    Vasselli, Ezio

    2011-01-01

    Lectures notes (in italian) of some arguments of classical analysis, with exercises. A particular emphasis to functional analysis and elementary operator algebra theory is given, by means of exercises and examples.

  3. Student notes as a mediating tool for learning in school subjects

    DEFF Research Database (Denmark)

    Christensen, Torben Spanget

    2016-01-01

    -writing function as a tool for a shift in identity from school child to student?. Perceptions of note-writing by two male students and students notes from the school subject bussines economics are analysed. It is concluded that note-writing can function as a tool for learning. Writing notes often allow students...... discource language which must be considered learning subjects. It is concluded that.note writing can mediate between subject discourse language and everyday language, and thereby also function as a tool to identity shift....

  4. Note-Taking and Memory in Different Media Environments

    Science.gov (United States)

    Lin, Lin; Bigenho, Chris

    2011-01-01

    Through this study the authors investigated undergraduate students' memory recall in three media environments with three note-taking options, following an A x B design with nine experiments. The three environments included no-distraction, auditory-distraction, and auditory-visual-distraction; while the three note-taking options included…

  5. Insights regarding the Usefulness of Partial Notes in Mathematics Courses

    Science.gov (United States)

    Cardetti, Fabiana; Khamsemanan, Nirattaya; Orgnero, M. Carolina

    2010-01-01

    Note-taking is a widespread practice used by college students to record information from lectures. Unfortunately, even successful students' notes are incomplete and, therefore, may lack the potential to positively impact their academic performance. Research suggests that instructors can help students improve their note-taking skills by using…

  6. Feature-Augmented Neural Networks for Patient Note De-identification

    OpenAIRE

    Lee, Ji Young; Dernoncourt, Franck; Uzuner, Ozlem; Szolovits, Peter

    2016-01-01

    Patient notes contain a wealth of information of potentially great interest to medical investigators. However, to protect patients' privacy, Protected Health Information (PHI) must be removed from the patient notes before they can be legally released, a process known as patient note de-identification. The main objective for a de-identification system is to have the highest possible recall. Recently, the first neural-network-based de-identification system has been proposed, yielding state-of-t...

  7. Bond-Length Distortions in Strained Semiconductor Alloys

    International Nuclear Information System (INIS)

    Woicik, J.C.; Pellegrino, J.G.; Steiner, B.; Miyano, K.E.; Bompadre, S.G.; Sorensen, L.B.; Lee, T.; Khalid, S.

    1997-01-01

    Extended x-ray absorption fine structure measurements performed at In-K edge have resolved the outstanding issue of bond-length strain in semiconductor-alloy heterostructures. We determine the In-As bond length to be 2.581±0.004 Angstrom in a buried, 213 Angstrom thick Ga 0.78 In 0.22 As layer grown coherently on GaAs(001). This bond length corresponds to a strain-induced contraction of 0.015±0.004 Angstrom relative to the In-As bond length in bulk Ga 1-x In x As of the same composition; it is consistent with a simple model which assumes a uniform bond-length distortion in the epilayer despite the inequivalent In-As and Ga-As bond lengths. copyright 1997 The American Physical Society

  8. Topological analysis of polymeric melts: chain-length effects and fast-converging estimators for entanglement length.

    Science.gov (United States)

    Hoy, Robert S; Foteinopoulou, Katerina; Kröger, Martin

    2009-09-01

    Primitive path analyses of entanglements are performed over a wide range of chain lengths for both bead spring and atomistic polyethylene polymer melts. Estimators for the entanglement length N_{e} which operate on results for a single chain length N are shown to produce systematic O(1/N) errors. The mathematical roots of these errors are identified as (a) treating chain ends as entanglements and (b) neglecting non-Gaussian corrections to chain and primitive path dimensions. The prefactors for the O(1/N) errors may be large; in general their magnitude depends both on the polymer model and the method used to obtain primitive paths. We propose, derive, and test new estimators which eliminate these systematic errors using information obtainable from the variation in entanglement characteristics with chain length. The new estimators produce accurate results for N_{e} from marginally entangled systems. Formulas based on direct enumeration of entanglements appear to converge faster and are simpler to apply.

  9. Temperature-dependence of Threshold Current Density-Length Product in Metallization Lines: A Revisit

    International Nuclear Information System (INIS)

    Duryat, Rahmat Saptono; Kim, Choong-Un

    2016-01-01

    One of the important phenomena in Electromigration (EM) is Blech Effect. The existence of Threshold Current Density-Length Product or EM Threshold has such fundamental and technological consequences in the design, manufacture, and testing of electronics. Temperature-dependence of Blech Product had been thermodynamically established and the real behavior of such interconnect materials have been extensively studied. The present paper reviewed the temperature-dependence of EM threshold in metallization lines of different materials and structure as found in relevant published articles. It is expected that the reader can see a big picture from the compiled data, which might be overlooked when it was examined in pieces. (paper)

  10. Wheat root length and not branching is altered in the presence of neighbours, including blackgrass.

    Directory of Open Access Journals (Sweden)

    Jessica A Finch

    Full Text Available The effect of neighbouring plants on crop root system architecture may directly interfere with water and nutrient acquisition, yet this important and interesting aspect of competition remains poorly understood. Here, the effect of the weed blackgrass (Alopecurus myosuroides Huds. on wheat (Triticum aestivum L. roots was tested, since a low density of this species (25 plants m-2 can lead to a 10% decrease in wheat yield and herbicide resistance is problematic. We used a simplified growth system based on gelled medium, to grow wheat alongside a neighbour, either another wheat plant, a blackgrass or Brachypodium dystachion individual (a model grass. A detailed analysis of wheat seminal root system architecture showed that the presence of a neighbour principally affected the root length, rather than number or diameter under a high nutrient regime. In particular, the length of first order lateral roots decreased significantly in the presence of blackgrass and Brachypodium. However, this effect was not noted when wheat plants were grown in low nutrient conditions. This suggests that wheat may be less sensitive to the presence of blackgrass when grown in low nutrient conditions. In addition, nutrient availability to the neighbour did not modulate the neighbour effect on wheat root architecture.

  11. Wheat root length and not branching is altered in the presence of neighbours, including blackgrass

    Science.gov (United States)

    Finch, Jessica A.; Guillaume, Gaëtan; French, Stephanie A.; Colaço, Renato D. D. R.; Davies, Julia M.

    2017-01-01

    The effect of neighbouring plants on crop root system architecture may directly interfere with water and nutrient acquisition, yet this important and interesting aspect of competition remains poorly understood. Here, the effect of the weed blackgrass (Alopecurus myosuroides Huds.) on wheat (Triticum aestivum L.) roots was tested, since a low density of this species (25 plants m-2) can lead to a 10% decrease in wheat yield and herbicide resistance is problematic. We used a simplified growth system based on gelled medium, to grow wheat alongside a neighbour, either another wheat plant, a blackgrass or Brachypodium dystachion individual (a model grass). A detailed analysis of wheat seminal root system architecture showed that the presence of a neighbour principally affected the root length, rather than number or diameter under a high nutrient regime. In particular, the length of first order lateral roots decreased significantly in the presence of blackgrass and Brachypodium. However, this effect was not noted when wheat plants were grown in low nutrient conditions. This suggests that wheat may be less sensitive to the presence of blackgrass when grown in low nutrient conditions. In addition, nutrient availability to the neighbour did not modulate the neighbour effect on wheat root architecture. PMID:28542446

  12. Economic issues of broiler production length

    Directory of Open Access Journals (Sweden)

    Szőllősi László

    2014-01-01

    Full Text Available The length of broiler production cycle is also an important factor when profitability is measured. This paper is to determine the effects of different market ages and down-time period, overall broiler production cycle length on performance and economic parameters based on Hungarian production and financial circumstances. A deterministic model was constructed to manage the function-like correlations of age-related daily weight gain, daily feed intake and daily mortality data. The results show that broiler production cycle length has a significant effect on production and economic performance. Cycle length is determined by the length of down-time and grow-out periods. If down-time period is reduced by one day, an average net income of EUR 0.55 per m2 is realizable. However, the production period is not directly proportional either with emerging costs or obtainable revenues. Profit maximization is attainable if the production period is 41-42 days.

  13. An energetic criterion for a micro-crack of finite length initiated in orthotropic bi-material notches

    Czech Academy of Sciences Publication Activity Database

    Profant, T.; Klusák, Jan; Ševeček, O.; Hrstka, M.; Kotoul, M.

    2013-01-01

    Roč. 110, SEP (2013), s. 396-409 ISSN 0013-7944 R&D Projects: GA ČR(CZ) GAP108/10/2049; GA ČR(CZ) GA101/09/1821 Institutional support: RVO:68081723 Keywords : crack initiation * bi-material notch * orthotropic bi-material notch * singular stress concentrator Subject RIV: JL - Materials Fatigue, Friction Mechanics Impact factor: 1.662, year: 2013

  14. Transgastric pure-NOTES peritoneoscopy and endoscopic ultrasonography for staging of gastrointestinal cancers

    DEFF Research Database (Denmark)

    Donatsky, Anders Meller; Vilmann, Peter; Meisner, Søren

    2012-01-01

    BACKGROUND: Human natural orifice transluminal endoscopic surgery (NOTES) has mainly been based on simultaneous laparoscopic assistance (hybrid NOTES), forgoing the theoretical benefits of the NOTES technique. This is due to a lack of NOTES-specific instruments and endoscopes, making pure-NOTES...... procedures difficult and time consuming. An area where pure NOTES could be adopted at its present stage of development is minimally invasive staging of gastrointestinal (GI) cancer. The aim of this study is to evaluate the feasibility of combining transgastric (TG) pure-NOTES peritoneoscopy...... and intraperitoneal endoscopic ultrasonography (ip-EUS) with intraluminal EUS (il-EUS) for peritoneal evaluation. METHODS: This was a feasibility and survival study where il-EUS followed by ip-EUS and peritoneoscopy was performed in 10 pigs subjected to TG pure NOTES. A score was given with regard to achieved...

  15. Rational use of anchor pile material of the thin retaining walls

    Directory of Open Access Journals (Sweden)

    Yushkov Boris Semenovich

    2014-12-01

    Full Text Available The article considers the urgency of application of the reinforced concrete anchor piles in the constructions of retaining structures associated with the possibility of establishing rigid joint of element interface and more durable pile constructions in the soil. The features of the inclined anchor piles work as a part of sheet-pile retaining walls are noted. There was performed a study of the stress-strain state of the inclined reinforced concrete anchor piles of the thin sheet-pile wall with the reinforced concrete face members of T-section, combined with piles by a longitudinal beam. The authors consider a constructive scheme of retaining structure and list the applied loads. The efforts in the anchor piles were determined. The bending-moment curves show the character of the force distribution along the pile. A form of the pile ensuring the rational distribution of material along the pile is presented. The distribution of efforts along the length and effect of filling on its operation in the soil were accepted as the criteria of construction solution for a pile. The substantiation of the proposed design of pile is presented in terms of its stress-strain state and the rational use of material. The authors made conclusions on the reasonability of adopted design solutions associated with an increase in the flexural strength of pile, increment of the ultimate pullout capacity, stability improvement, effective use of backfill and exception of the «out of operation» areas of the pile.

  16. Grouping notes through nodes: The functions of Post-It notes in design team cognition

    DEFF Research Database (Denmark)

    Dove, Graham; Abildgaard, Sille Julie Jøhnk; Biskjaer, Michael Mose

    2018-01-01

    We investigate the way Post-It notes support creative design team practice, focusing on how they function as cognitive externalisations that, through grouping activities, support categorisation qualities associated with semantic long-term memory. We use a multimodal approach, drawing...

  17. Relativistic length agony continued

    Directory of Open Access Journals (Sweden)

    Redžić D.V.

    2014-01-01

    Full Text Available We made an attempt to remedy recent confusing treatments of some basic relativistic concepts and results. Following the argument presented in an earlier paper (Redžić 2008b, we discussed the misconceptions that are recurrent points in the literature devoted to teaching relativity such as: there is no change in the object in Special Relativity, illusory character of relativistic length contraction, stresses and strains induced by Lorentz contraction, and related issues. We gave several examples of the traps of everyday language that lurk in Special Relativity. To remove a possible conceptual and terminological muddle, we made a distinction between the relativistic length reduction and relativistic FitzGerald-Lorentz contraction, corresponding to a passive and an active aspect of length contraction, respectively; we pointed out that both aspects have fundamental dynamical contents. As an illustration of our considerations, we discussed briefly the Dewan-Beran-Bell spaceship paradox and the ‘pole in a barn’ paradox. [Projekat Ministarstva nauke Republike Srbije, br. 171028

  18. Communications received from certain Member States regarding guidelines for transfers of nuclear-related dual-use equipment, materials, software and related technology

    International Nuclear Information System (INIS)

    2005-01-01

    The Director General of the International Atomic Energy Agency has received Notes Verbales dated 25 October 2004 from the Resident Representatives to the Agency of Argentina, Australia, Austria, Belgium, Brazil, Canada, Cyprus, Czech Republic, Estonia, Finland, France, Greece, Hungary, Italy, Japan, Malta, Netherlands, Norway, Republic of Korea, South Africa, Spain, Sweden, Turkey, Ukraine, the United Kingdom of Great Britain and Northern Ireland and the United States of America, relating to transfers of nuclear-related dual-use equipment, materials, software and related technology. The purpose of the Notes Verbales is to provide further information on those Governments' guidelines for transfers of nuclear-related dual-use equipment, materials, software and related technology. In the light of the wish expressed at the end of each Note Verbale, the text of the Notes Verbales is attached. The attachment to these Notes Verbales is also reproduced in full

  19. Communications received from certain Member States regarding guidelines for transfers of nuclear-related dual-use equipment, materials, software and related technology

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-02-23

    The Director General of the International Atomic Energy Agency has received Notes Verbales dated 25 October 2004 from the Resident Representatives to the Agency of Argentina, Australia, Austria, Belgium, Brazil, Canada, Cyprus, Czech Republic, Estonia, Finland, France, Greece, Hungary, Italy, Japan, Malta, Netherlands, Norway, Republic of Korea, South Africa, Spain, Sweden, Turkey, Ukraine, the United Kingdom of Great Britain and Northern Ireland and the United States of America, relating to transfers of nuclear-related dual-use equipment, materials, software and related technology. The purpose of the Notes Verbales is to provide further information on those Governments' guidelines for transfers of nuclear-related dual-use equipment, materials, software and related technology. In the light of the wish expressed at the end of each Note Verbale, the text of the Notes Verbales is attached. The attachment to these Notes Verbales is also reproduced in full.

  20. Length scale hierarchy and spatiotemporal change of alluvial morphologies over the Selenga River delta, Russia

    Science.gov (United States)

    Dong, T. Y.; Nittrouer, J.; McElroy, B. J.; Ma, H.; Czapiga, M. J.; Il'icheva, E.; Pavlov, M.; Parker, G.

    2017-12-01

    The movement of water and sediment in natural channels creates various types of alluvial morphologies that span length scales from dunes to deltas. The behavior of these morphologies is controlled microscopically by hydrodynamic conditions and bed material size, and macroscopically by hydrologic and geological settings. Alluvial morphologies can be modeled as either diffusive or kinematic waves, in accordance with their respective boundary conditions. Recently, it has been shown that the difference between these two dynamic behaviors of alluvial morphologies can be characterized by the backwater number, which is a dimensionless value normalizing the length scale of a morphological feature to its local hydrodynamic condition. Application of the backwater number has proven useful for evaluating the size of morphologies, including deltas (e.g., by assessing the preferential avulsion location of a lobe), and for comparing bedform types across different fluvial systems. Yet two critical questions emerge when applying the backwater number: First, how do different types of alluvial morphologies compare within a single deltaic system, where there is a hydrodynamic transition from uniform to non-uniform flow? Second, how do different types of morphologies evolve temporally within a system as a function of changing water discharge? This study addresses these questions by compiling and analyzing field data from the Selenga River delta, Russia, which include measurements of flow velocity, channel geometry, bed material grain size, and channel slope, as well as length scales of various morphologies, including dunes, island bars, meanders, bifurcations, and delta lobes. Data analyses reveal that the length scale of morphologies decrease and the backwater number increases as flow transitions from uniform to non-uniform conditions progressing downstream. It is shown that the evaluated length scale hierarchy and planform distribution of different morphologies can be used to

  1. An Exploration of Note-Taking in an Online Calculus Course

    Science.gov (United States)

    van de Sande, Carla; Abramson, Jay; Judson-Garcia, Julia

    2017-01-01

    Taking notes is a popular activity for students attending instructional lectures and has been linked to achievement. Research on note-taking has shown that the contents and usefulness of student notes depends on several factors, including the pace of the lecture and the presence of organizational and selection cues. However, this research has…

  2. Advances in materials science, Metals and Ceramics Division. Triannual progress report, October 1979-January 1980

    Energy Technology Data Exchange (ETDEWEB)

    1980-03-31

    Progress is summarized concerning magnetic fusion energy materials, laser fusion energy, aluminium-air battery and vehicle, geothermal research, oil-shale research, nuclear waste management, office of basic energy sciences research, and materials research notes. (FS)

  3. Note on the ABC Conjecture

    OpenAIRE

    Carella, N. A.

    2006-01-01

    This note imparts heuristic arguments and theorectical evidences that contradict the abc conjecture over the rational numbers. In addition, the rudimentary datails for transforming this problem into the doimain of equidistribution theory are provided.

  4. Lecture Notes in Statistics. 3rd Semester

    DEFF Research Database (Denmark)

    The lecture note is prepared to meet the requirements for the 3rd semester course in statistics at the Aarhus School of Business. It focuses on multiple regression models, analysis of variance, and log-linear models.......The lecture note is prepared to meet the requirements for the 3rd semester course in statistics at the Aarhus School of Business. It focuses on multiple regression models, analysis of variance, and log-linear models....

  5. Relativistic distances, sizes, lengths

    International Nuclear Information System (INIS)

    Strel'tsov, V.N.

    1992-01-01

    Such notion as light or retarded distance, field size, formation way, visible size of a body, relativistic or radar length and wave length of light from a moving atom are considered. The relation between these notions is cleared up, their classification is given. It is stressed that the formation way is defined by the field size of a moving particle. In the case of the electromagnetic field, longitudinal sizes increase proportionally γ 2 with growing charge velocity (γ is the Lorentz-factor). 18 refs

  6. Association of Leukocyte Telomere Length with Fatigue in Nondisabled Older Adults

    DEFF Research Database (Denmark)

    Bendix, Laila; Thinggaard, Mikael; Kimura, Masayuki

    2014-01-01

    Introduction. Fatigue is often present in older adults with no identified underlying cause. The accruing burden of oxidative stress and inflammation might be underlying factors of fatigue. We therefore hypothesized that leukocyte telomere length (LTL) is relatively short in older adults who...... experience fatigue. Materials and Methods. We assessed 439 older nondisabled Danish twins. LTL was measured using Southern blots of terminal restriction fragments. Fatigue was measured by the Mob-T Scale based on questions on whether the respondents felt fatigued after performing six mobility items. Results...

  7. Effect of UV on building materials in New Zealand

    International Nuclear Information System (INIS)

    Bennett, A.F.

    1993-01-01

    Building materials can be divided into two main classes; organic or polymeric based and inorganic materials. Inorganic materials are in most cases largely unaffected by UV radiation. Many common polymers have bonds sensitive to radiation in the UV region. Absorption of radiation of these wavelengths will lead to excitation of electrons which can lead to isomerisation, chain scissors, cross linking and free radical formation. It is worth noting that the effects of UV radiation are always acting synergistically with other environmental effects. (author). 4 refs., 2 tabs

  8. GeneNotes – A novel information management software for biologists

    Directory of Open Access Journals (Sweden)

    Wong Wing H

    2005-02-01

    Full Text Available Abstract Background Collecting and managing information is a challenging task in a genome-wide profiling research project. Most databases and online computational tools require a direct human involvement. Information and computational results are presented in various multimedia formats (e.g., text, image, PDF, word files, etc., many of which cannot be automatically processed by computers in biologically meaningful ways. In addition, the quality of computational results is far from perfect and requires nontrivial manual examination. The timely selection, integration and interpretation of heterogeneous biological information still heavily rely on the sensibility of biologists. Biologists often feel overwhelmed by the huge amount of and the great diversity of distributed heterogeneous biological information. Description We developed an information management application called GeneNotes. GeneNotes is the first application that allows users to collect and manage multimedia biological information about genes/ESTs. GeneNotes provides an integrated environment for users to surf the Internet, collect notes for genes/ESTs, and retrieve notes. GeneNotes is supported by a server that integrates gene annotations from many major databases (e.g., HGNC, MGI, etc.. GeneNotes uses the integrated gene annotations to (a identify genes given various types of gene IDs (e.g., RefSeq ID, GenBank ID, etc., and (b provide quick views of genes. GeneNotes is free for academic usage. The program and the tutorials are available at: http://bayes.fas.harvard.edu/genenotes/. Conclusions GeneNotes provides a novel human-computer interface to assist researchers to collect and manage biological information. It also provides a platform for studying how users behave when they manipulate biological information. The results of such study can lead to innovation of more intelligent human-computer interfaces that greatly shorten the cycle of biology research.

  9. Note-Taking with Computers: Exploring Alternative Strategies for Improved Recall

    Science.gov (United States)

    Bui, Dung C.; Myerson, Joel; Hale, Sandra

    2013-01-01

    Three experiments examined note-taking strategies and their relation to recall. In Experiment 1, participants were instructed either to take organized lecture notes or to try and transcribe the lecture, and they either took their notes by hand or typed them into a computer. Those instructed to transcribe the lecture using a computer showed the…

  10. The Impact of Novice Counselors' Note-Taking Behavior on Recall and Judgment

    Science.gov (United States)

    Lo, Chu-Ling; Wadsworth, John

    2014-01-01

    Purpose: To examine the effect of note-taking on novice counselors' recall and judgment of interview information in four situations: no notes, taking notes, taking notes and reviewing these notes, and reviewing notes taken by others. Method: The sample included 13 counselors-in-training recruited from a master's level training program in…

  11. Revisiting convergence: A research note.

    Science.gov (United States)

    Clark, Rob

    2015-09-01

    A number of recent studies show that income inequality is declining between countries. In this research note, I question the significance of this trend by examining the role of initial conditions in producing convergence. An important (but neglected) property of inequality dynamics is the tendency for extreme distributions to become more moderate. When income disparities are large, the subsequent trend is biased toward convergence. Conversely, when initial conditions approach parity, divergence becomes the more likely long-term outcome. I apply this principle to trends in GDP PC across 127 countries during the 1980-2010 period. Using counterfactual analysis, I manipulate the initial level of inequality in GDP PC while holding constant each country's observed growth rate during the sample period. I find that the growth dynamics of GDP PC produce either convergence or divergence based simply on the initial distribution of income. The point of transition occurs at a moderate level of inequality, whether using population weights (Gini=.365) or not (Gini=.377). I conclude that the recent convergence observed in GDP PC is primarily a function of large income gaps between countries and would not have materialized at more moderate levels of initial inequality. By contrast, an examination of the pre-1950 period reveals divergent growth patterns that are not sensitive to initial conditions. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Patients who share transparent visit notes with others: characteristics, risks, and benefits.

    Science.gov (United States)

    Jackson, Sara L; Mejilla, Roanne; Darer, Jonathan D; Oster, Natalia V; Ralston, James D; Leveille, Suzanne G; Walker, Jan; Delbanco, Tom; Elmore, Joann G

    2014-11-12

    Inviting patients to read their primary care visit notes may improve communication and help them engage more actively in their health care. Little is known about how patients will use the opportunity to share their visit notes with family members or caregivers, or what the benefits might be. Our goal was to evaluate the characteristics of patients who reported sharing their visit notes during the course of the study, including their views on associated benefits and risks. The OpenNotes study invited patients to access their primary care providers' visit notes in Massachusetts, Pennsylvania, and Washington. Pre- and post-intervention surveys assessed patient demographics, standardized measures of patient-doctor communication, sharing of visit notes with others during the study, and specific health behaviors reflecting the potential benefits and risks of offering patients easy access to their visit notes. More than half (55.43%, 2503/4516) of the participants who reported viewing at least one visit note would like the option of letting family members or friends have their own Web access to their visit notes, and 21.70% (980/4516) reported sharing their visit notes with someone during the study year. Men, and those retired or unable to work, were significantly more likely to share visit notes, and those sharing were neither more nor less concerned about their privacy than were non-sharers. Compared to participants who did not share clinic notes, those who shared were more likely to report taking better care of themselves and taking their medications as prescribed, after adjustment for age, gender, employment status, and study site. One in five OpenNotes patients shared a visit note with someone, and those sharing Web access to their visit notes reported better adherence to self-care and medications. As health information technology systems increase patients' ability to access their medical records, facilitating access to caregivers may improve perceived health

  13. Atomistic Simulations of Small-scale Materials Tests of Nuclear Materials

    International Nuclear Information System (INIS)

    Shin, Chan Sun; Jin, Hyung Ha; Kwon, Jun Hyun

    2012-01-01

    Degradation of materials properties under neutron irradiation is one of the key issues affecting the lifetime of nuclear reactors. Evaluating the property changes of materials due to irradiations and understanding the role of microstructural changes on mechanical properties are required for ensuring reliable and safe operation of a nuclear reactor. However, high dose of neuron irradiation capabilities are rather limited and it is difficult to discriminate various factors affecting the property changes of materials. Ion beam irradiation can be used to investigate radiation damage to materials in a controlled way, but has the main limitation of small penetration depth in the length scale of micro meters. Over the past decade, the interest in the investigations of size-dependent mechanical properties has promoted the development of various small-scale materials tests, e.g. nanoindentation and micro/nano-pillar compression tests. Small-scale materials tests can address the issue of the limitation of small penetration depth of ion irradiation. In this paper, we present small-scale materials tests (experiments and simulation) which are applied to study the size and irradiation effects on mechanical properties. We have performed molecular dynamics simulations of nanoindentation and nanopillar compression tests. These atomistic simulations are expected to significantly contribute to the investigation of the fundamental deformation mechanism of small scale irradiated materials

  14. Multiscale dipole relaxation in dielectric materials

    DEFF Research Database (Denmark)

    Hansen, Jesper Schmidt

    2016-01-01

    Dipole relaxation from thermally induced perturbations is investigated on different length scales for dielectric materials. From the continuum dynamical equations for the polarisation, expressions for the transverse and longitudinal dipole autocorrelation functions are derived in the limit where ...

  15. Effects of the Utterance length on Fluency of Conversational Speech in Stuttering Persian-Speaker Children and Adults

    Directory of Open Access Journals (Sweden)

    Tabassom A'zimi

    2013-10-01

    Full Text Available Objective: recently, researchers have increasingly turned to study the relation between stuttering and utterance length. This study investigates the effect of utterance length on the amount of speech dysfluency in stuttering Persian-speaking children and adults in conversational speech. The obtained results can pave the way to reach a better understanding of stuttering of child and adults, as well as finding more appropriate treatments. Materials & Methods: in this descriptive- analysis study, the participants were 15 stuttering Persian- speaker adults, upper from 15 years old, and 15 stuttering Persian- speaker children in the age range of 4-6. In this study, first 30 minutes sample of adults and child's spontaneous speech was provided and then utterances of each person studied for the amount of dysfluency and utterance length. The obtained information intered to computer via spss software and analyzed using paired T test. Results: In both groups of stuttering children and adults, with increase of utterance length, there was a significant increase in the amount of dysfluency. Conclusion: The results of this study showed that by increase of utterance length at the spontaneous speech level, stuttering children and adults had more dysfluency amount. Also, by increase of utterance length, dysfluency amount of stuttering children and adults increased samely.

  16. 29 CFR Appendix to Subpart B of... - Reporter's Notes

    Science.gov (United States)

    2010-07-01

    ... Part 18—Reporter's Notes Reporter's Introductory Note The Rules of Evidence for the United States... contained in its files, such as the revenue statistics contained in the reports submitted to it by a...

  17. Extreme telomere length dimorphism in the Tasmanian devil and related marsupials suggests parental control of telomere length.

    Directory of Open Access Journals (Sweden)

    Hannah S Bender

    Full Text Available Telomeres, specialised structures that protect chromosome ends, play a critical role in preserving chromosome integrity. Telomere dynamics in the Tasmanian devil (Sarcophilus harrisii are of particular interest in light of the emergence of devil facial tumour disease (DFTD, a transmissible malignancy that causes rapid mortality and threatens the species with extinction. We used fluorescent in situ hybridisation to investigate telomere length in DFTD cells, in healthy Tasmanian devils and in four closely related marsupial species. Here we report that animals in the Order Dasyuromorphia have chromosomes characterised by striking telomere length dimorphism between homologues. Findings in sex chromosomes suggest that telomere length dimorphism may be regulated by events in the parental germlines. Long telomeres on the Y chromosome imply that telomere lengthening occurs during spermatogenesis, whereas telomere diminution occurs during oogenesis. Although found in several somatic cell tissue types, telomere length dimorphism was not found in DFTD cancer cells, which are characterised by uniformly short telomeres. This is, to our knowledge, the first report of naturally occurring telomere length dimorphism in any species and suggests a novel strategy of telomere length control. Comparative studies in five distantly related marsupials and a monotreme indicate that telomere dimorphism evolved at least 50 million years ago.

  18. Impedance of finite length resistive cylinder

    Directory of Open Access Journals (Sweden)

    S. Krinsky

    2004-11-01

    Full Text Available We determine the impedance of a cylindrical metal tube (resistor of radius a, length g, and conductivity σ attached at each end to perfect conductors of semi-infinite length. Our main interest is in the asymptotic behavior of the impedance at high frequency (k≫1/a. In the equilibrium regime, ka^{2}≪g, the impedance per unit length is accurately described by the well-known result for an infinite length tube with conductivity σ. In the transient regime, ka^{2}≫g, where the contribution of transition radiation arising from the discontinuity in conductivity is important, we derive an analytic expression for the impedance and compute the short-range wakefield. The analytic results are shown to agree with numerical evaluation of the impedance.

  19. "Seeing things in my head": a synesthete's images for music and notes.

    Science.gov (United States)

    Mills, Carol Bergfeld; Boteler, Edith Howell; Larcombe, Glenda K

    2003-01-01

    We explored synesthetic experiences (photisms) elicited by music and notes for GS, a 22-year-old female college student, who is a genuine digit synesthete (Mills et al 1999 Cognitive Neuropsychology 16 181-191). After extensive interviews, we conducted five studies using synthesizer notes in different octaves and in different instrument sounds. GS described, drew, or selected her photisms from alternatives. The results were: (a) her photisms had shape, color, movement, and texture: (b) different instruments had photisms with different shapes and families of instruments had similar shapes; (c) low-pitched notes were darker and larger than high notes; (d) instrument and pitch affected each other; (e) a given note was perceived as darker after a high note than after a low note; and (f) GS's drawings of notes became more consistent with repeated trials. Theoretical observations are discussed on the basis of these results.

  20. Notes on Neotropical Eumeninae, with the description of a new species of Pachodynerus de Saussure (Hymenoptera, Vespidae

    Directory of Open Access Journals (Sweden)

    Marcel Gustavo Hermes

    2013-06-01

    Full Text Available Notes on Neotropical Eumeninae, with the description of a new species of Pachodynerus de Saussure (Hymenoptera, Vespidae. Taxonomic information on Neotropical Eumeninae is provided. A new species, Pachodynerus fessatus sp. nov. is described from southeastern São Paulo, Brazil. Additional material of Pachodynerus sericeus (Fox was examined, representing the first further specimens after the original description and including the previously unknown male. The examination of new material of the genus Stenonartonia adds some new distribution records and shows some previously unrecorded individual variation for some species. The males of Stenonartonia guaraya Garcete-Barrett and Stenonartonia rejectoides Garcete-Barrett are described for the first time.

  1. The STS-constructivist reform: some discordant notes | Nworgu ...

    African Journals Online (AJOL)

    It would appear that as many more voices join in the advocacy for STS constructivist Reform in science teaching/learning, more discordant notes are emitted. The purpose of the paper therefore, was to spotlight some of these discordant notes emitted in the course of the on-going reform advocacy. Specifically, three of such ...

  2. 26 CFR 25.2512-4 - Valuation of notes.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 14 2010-04-01 2010-04-01 false Valuation of notes. 25.2512-4 Section 25.2512-4... GIFT TAX; GIFTS MADE AFTER DECEMBER 31, 1954 Transfers § 25.2512-4 Valuation of notes. The fair market... the property, if any, pledged or mortgaged as security is insufficient to satisfy it. ...

  3. Simulative Global Warming Negatively Affects Cotton Fiber Length through Shortening Fiber Rapid Elongation Duration.

    Science.gov (United States)

    Dai, Yanjiao; Yang, Jiashuo; Hu, Wei; Zahoor, Rizwan; Chen, Binglin; Zhao, Wenqing; Meng, Yali; Zhou, Zhiguo

    2017-08-23

    Global warming could possibly increase the air temperature by 1.8-4.0 °C in the coming decade. Cotton fiber is an essential raw material for the textile industry. Fiber length, which was found negatively related to the excessively high temperature, determines yarn quality to a great extent. To investigate the effects of global warming on cotton fiber length and its mechaism, cottons grown in artificially elevated temperature (34.6/30.5 °C, T day /T night ) and ambient temperature (31.6/27.3 °C) regions have been investigated. Becaused of the high sensitivities of enzymes V-ATPase, PEPC, and genes GhXTH1 and GhXTH2 during fiber elongation when responding to high temperature stress, the fiber rapid elongation duration (FRED) has been shortened, which led to a significant suppression on final fiber length. Through comprehensive analysis, T night had a great influence on fiber elongation, which means T n could be deemed as an ideal index for forecasting the degree of high temperature stress would happen to cotton fiber property in future. Therefore, we speculate the global warming would bring unfavorable effects on cotton fiber length, which needs to take actions in advance for minimizing the loss in cotton production.

  4. Performance of RC columns with partial length corrosion

    International Nuclear Information System (INIS)

    Wang Xiaohui; Liang Fayun

    2008-01-01

    Experimental and analytical studies on the load capacity of reinforced concrete (RC) columns with partial length corrosion are presented, where only a fraction of the column length was corroded. Twelve simply supported columns were eccentrically loaded. The primary variables were partial length corrosion in tensile or compressive zone and the corrosion level within this length. The failure of the corroded column occurs in the partial length, mainly developed from or located nearby or merged with the longitudinal corrosion cracks. For RC column with large eccentricity, load capacity of the column is mainly influenced by the partial length corrosion in tensile zone; while for RC column with small eccentricity, load capacity of the column greatly decreases due to the partial length corrosion in compressive zone. The destruction of the longitudinally mechanical integrality of the column in the partial length leads to this great reduction of the load capacity of the RC column

  5. Penile length and circumference: an Indian study.

    Science.gov (United States)

    Promodu, K; Shanmughadas, K V; Bhat, S; Nair, K R

    2007-01-01

    Apprehension about the normal size of penis is a major concern for men. Aim of the present investigation is to estimate the penile length and circumference of Indian males and to compare the results with the data from other countries. Results will help in counseling the patients worried about the penile size and seeking penis enlargement surgery. Penile length in flaccid and stretched conditions and circumference were measured in a group of 301 physically normal men. Erected length and circumference were measured for 93 subjects. Mean flaccid length was found to be 8.21 cm, mean stretched length 10.88 cm and circumference 9.14 cm. Mean erected length was found to be 13.01 cm and erected circumference was 11.46 cm. Penile dimensions are found to be correlated with anthropometric parameters. Insight into the normative data of penile size of Indian males obtained. There are significant differences in the mean penile length and circumference of Indian sample compared to the data reported from other countries. Study need to be continued with a large sample to establish a normative data applicable to the general population.

  6. Determination of thermal neutrons diffusion length in graphite; Determinacion de la Longitud de Difusion de los Neutrones Termicos en Grafito

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Fite, J

    1959-07-01

    The diffusion length of thermal neutrons in graphite using the less possible quantity of material has been determined. The proceeding used was the measurement in a graphite pile which has a punctual source of rapid neutrons inside surrounded by a reflector medium (paraffin or water). The measurement was done in the following conditions: a) introducing an aluminium plate between both materials. b) Introducing a cadmium plate between both materials. (Author) 91 refs.

  7. [The archeology of slavery on Jesuit fazendas: first research notes].

    Science.gov (United States)

    Symanski, Luís Cláudio P; Gomes, Flávio

    2012-12-01

    These preliminary research notes present theoretical and methodological questions regarding a recently inaugurated investigation in historical archeology that intends to analyze daily life under slavery, demographic regimes, cultural practices, and so on. A survey of archeological sites on former 'senzalas' (slave quarters) and slave-owning fazendas in the Paraíba Valley and northern part of the state of Rio de Janeiro is currently in progress. With the cooperation of historians, archeologists, and anthropologists, records of the material culture of slave populations, which originally comprised indigenes and later Africans, are being located at excavations underway on the fazenda that is part of the Jesuit school in Campos dos Goytacazes, Rio de Janeiro, first run by the clergy and later by members of the laity in the seventeenth, eighteenth, and nineteenth centuries.

  8. Communications received from certain Member States regarding guidelines for the export of nuclear material, equipment and technology. Nuclear-related dual-use transfers

    International Nuclear Information System (INIS)

    1995-10-01

    The Director General has received notes verbales dated 30 June 1995 from the Resident Representatives to the Agency of Argentina, Australia, Austria, Belgium, Bulgaria, Canada, the Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Japan, Luxembourg, the Netherlands, New Zealand, Norway, Poland, Portugal, Romania, the Slovak Republic, South Africa, Spain, Sweden, Switzerland, the United Kingdom of Great Britain and Northern Ireland, and the United States of America relating to the export of nuclear material, equipment and technology. The purpose of the notes verbales is to provide further information on those Governments' Guidelines for Transfers of Nuclear-related Dual-use Equipment, Material and related Technology. In the light of the wish expressed at the end of each note verbale, the text of the notes verbales is annexed hereto. The enclosure to these notes verbales is also reproduced in full in the Annex

  9. Communications received from certain Member States regarding guidelines for the export of nuclear material, equipment and technology. Nuclear-related dual-use transfers

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-10-01

    The Director General has received notes verbales dated 30 June 1995 from the Resident Representatives to the Agency of Argentina, Australia, Austria, Belgium, Bulgaria, Canada, the Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Japan, Luxembourg, the Netherlands, New Zealand, Norway, Poland, Portugal, Romania, the Slovak Republic, South Africa, Spain, Sweden, Switzerland, the United Kingdom of Great Britain and Northern Ireland, and the United States of America relating to the export of nuclear material, equipment and technology. The purpose of the notes verbales is to provide further information on those Governments` Guidelines for Transfers of Nuclear-related Dual-use Equipment, Material and related Technology. In the light of the wish expressed at the end of each note verbale, the text of the notes verbales is annexed hereto. The enclosure to these notes verbales is also reproduced in full in the Annex.

  10. 26 CFR 20.2031-4 - Valuation of notes.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 14 2010-04-01 2010-04-01 false Valuation of notes. 20.2031-4 Section 20.2031-4... ESTATE TAX; ESTATES OF DECEDENTS DYING AFTER AUGUST 16, 1954 Gross Estate § 20.2031-4 Valuation of notes... of the party or parties liable, or for other cause), and that any property pledged or mortgaged as...

  11. Bunch Length Measurements in SPEAR3

    Energy Technology Data Exchange (ETDEWEB)

    Corbett, W.J.; Fisher, A.; Huang, X.; Safranek, J.; Sebek, J.; /SLAC; Lumpkin, A.; /Argonne; Sannibale, F.; /LBL, Berkeley; Mok, W.; /Unlisted

    2007-11-28

    A series of bunch length measurements were made in SPEAR3 for two different machine optics. In the achromatic optics the bunch length increases from the low-current value of 16.6ps rms to about 30ps at 25ma/bunch yielding an inductive impedance of -0.17{Omega}. Reducing the momentum compaction factor by a factor of {approx}60 [1] yields a low-current bunch length of {approx}4ps rms. In this paper we review the experimental setup and results.

  12. Xyce parallel electronic simulator release notes.

    Energy Technology Data Exchange (ETDEWEB)

    Keiter, Eric R; Hoekstra, Robert John; Mei, Ting; Russo, Thomas V.; Schiek, Richard Louis; Thornquist, Heidi K.; Rankin, Eric Lamont; Coffey, Todd S; Pawlowski, Roger P; Santarelli, Keith R.

    2010-05-01

    The Xyce Parallel Electronic Simulator has been written to support, in a rigorous manner, the simulation needs of the Sandia National Laboratories electrical designers. Specific requirements include, among others, the ability to solve extremely large circuit problems by supporting large-scale parallel computing platforms, improved numerical performance and object-oriented code design and implementation. The Xyce release notes describe: Hardware and software requirements New features and enhancements Any defects fixed since the last release Current known defects and defect workarounds For up-to-date information not available at the time these notes were produced, please visit the Xyce web page at http://www.cs.sandia.gov/xyce.

  13. Communications received from certain Member States regarding guidelines for transfers of nuclear-related dual-use equipment, materials, software and related technology

    International Nuclear Information System (INIS)

    2003-01-01

    The Director General of the International Atomic Energy Agency has received Notes Verbales dated 28 February 2003 from the Resident Representatives to the Agency of Argentina, Austria, Belgium, Bulgaria, Canada, Cyprus, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Italy, Japan, Kazakhstan, Latvia, Netherlands, Norway, Portugal, Republic of Korea, Slovakia, Slovenia, South Africa, Spain, Sweden, Switzerland, Turkey, Ukraine, the United Kingdom of Great Britain and Northern Ireland, and the United States of America, relating to transfers of nuclear-related dual-use equipment, materials, software and related technology. The purpose of the Note Verbales is to provide further information on those Governments' Guidelines for Transfers of Nuclear-related Dual-use Equipment, Materials, Software and Related Technology. In the light of the wish expressed at the end of each Note Verbale, the text of the Notes Verbales is attached. The attachment to these Notes Verbales is also reproduced in full

  14. Communications received from certain Member States regarding guidelines for transfers of nuclear-related dual-use equipment, materials, software and related technology

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-05-16

    The Director General of the International Atomic Energy Agency has received Notes Verbales dated 28 February 2003 from the Resident Representatives to the Agency of Argentina, Austria, Belgium, Bulgaria, Canada, Cyprus, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Italy, Japan, Kazakhstan, Latvia, Netherlands, Norway, Portugal, Republic of Korea, Slovakia, Slovenia, South Africa, Spain, Sweden, Switzerland, Turkey, Ukraine, the United Kingdom of Great Britain and Northern Ireland, and the United States of America, relating to transfers of nuclear-related dual-use equipment, materials, software and related technology. The purpose of the Note Verbales is to provide further information on those Governments' Guidelines for Transfers of Nuclear-related Dual-use Equipment, Materials, Software and Related Technology. In the light of the wish expressed at the end of each Note Verbale, the text of the Notes Verbales is attached. The attachment to these Notes Verbales is also reproduced in full.

  15. Designing Competency-Based Materials for the Automotive Mechanics Curriculum

    Science.gov (United States)

    Richardson, Roger L.

    1977-01-01

    Describes the Career Education Center's (Florida State University) development of the "Automotive Mechanics Catalog" (a job inventory noting performance objectives for specific occupational programs), using the Vocational-Technical Education Consortium of States (V-TECS) model. Also describes the development of curriculum materials using…

  16. Fracture of anisotropic materials with plastic strain-gradient effects

    DEFF Research Database (Denmark)

    Legarth, Brian Nyvang

    2013-01-01

    A unit cell is adopted to numerically analyze the effect of plastic anisotropy on frac-ture evolution in a micro-reinforced fiber-composite. The matrix material exhibit size-effects and an anisotropic strain-gradient plasticity model accounting for such size-effects through a mate-rial length scale...

  17. LENGTH-WEIGHT RELATIONSHIP AND CONDITION FACTOR OF ...

    African Journals Online (AJOL)

    Data Collection and Analysis. The measurements of length (cm), weight (g) and the condition factor of individual fish sampled were recorded. The relationship between length and weight of the fish was examined by simple linear regression using WINKS software. The variations in the length-weight represented by 'b' were.

  18. Correlation of Index Finger Length (2D with Height, Weight and BMI in Adult Bangladeshi Male

    Directory of Open Access Journals (Sweden)

    Karim Rezwan Hasan

    2017-05-01

    Full Text Available Background: Human hand is one of the most versatile parts of the human body which plays an important role in modern medical science and evolutionary biology. By virtue of evolution and genetic arrangements, digital lengths vary from person to person according to age, sex, races, occupation or even environmental influences. It has been found that the digital lengths and their ratios are not same in different sexes and even in both hands of same individual. Specially, index to ring digit lengths and their ratios which already have been proved to represent sexual dimorphism may differ in both hands of an individual and show positive correlations with other morphological attributes like height, weight and BMI. Objectives: To analyze the variation of index finger (2D length and its correlation with height, weight and BMI in adult Bangladeshi male. Materials and Methods: This cross-sectional analytical study was conducted in the department of Anatomy, Dhaka Medical College, Dhaka from July 2012 to June 2013 on 100 male MBBS students (20−25 years of age. With the help of digital vernier caliper measurements of index finger length (2D was recorded. Height and weight were measured by the stadiometer and weighing scale respectively. BMI was calculated from height and weight. Pearson’s correlation analysis was done to find out the correlation of index finger length with height, weight and BMI. Results: Significant correlation has been found between the lengths of index fingers (2D and height (p0.05. Conclusion: In this study, we found variation in index finger lengths of both hands of Bangladeshi male subjects, which needs further study and comparison.

  19. Needs analysis for developing a virtual-reality NOTES simulator.

    Science.gov (United States)

    Sankaranarayanan, Ganesh; Matthes, Kai; Nemani, Arun; Ahn, Woojin; Kato, Masayuki; Jones, Daniel B; Schwaitzberg, Steven; De, Suvranu

    2013-05-01

    INTRODUCTION AND STUDY AIM: Natural orifice translumenal endoscopic surgery (NOTES) is an emerging surgical technique that requires a cautious adoption approach to ensure patient safety. High-fidelity virtual-reality-based simulators allow development of new surgical procedures and tools and train medical personnel without risk to human patients. As part of a project funded by the National Institutes of Health, we are developing the virtual transluminal endoscopic surgery trainer (VTEST) for this purpose. The objective of this study is to conduct a structured needs analysis to identify the design parameters for such a virtual-reality-based simulator for NOTES. A 30-point questionnaire was distributed at the 2011 National Orifice Surgery Consortium for Assessment and Research meeting to obtain responses from experts. Ordinal logistic regression and the Wilcoxon rank-sum test were used for analysis. A total of 22 NOTES experts participated in the study. Cholecystectomy (CE, 68 %) followed by appendectomy (AE, 63 %) (CE vs AE, p = 0.0521) was selected as the first choice for simulation. Flexible (FL, 47 %) and hybrid (HY, 47 %) approaches were equally favorable compared with rigid (RI, 6 %) with p virtual NOTES simulator in training and testing new tools for NOTES were rated very high by the participants. Our study reinforces the importance of developing a virtual NOTES simulator and clearly presents expert preferences. The results of this analysis will direct our initial development of the VTEST platform.

  20. Prediction of unknown deep foundation lengths using the Hilbert Huang Transform (HHT

    Directory of Open Access Journals (Sweden)

    Ahmed T.M. Farid

    2012-08-01

    Full Text Available Prediction of unknown deep foundation embedment depth is a great deal nowadays, especially in case of upgrading or rehabilitation of old structures. Many old bridges and marine or pier structures in the United States are established using deep foundations system of timber piles and their foundation records do not exist. Non-Destructive Testing (NDT or Non-Destructive Evaluation (NDE method for a great variety of materials and structures has become an integral part of many tests. However, the process of testing long piles, deeply embedded in the ground, is more complex than (NDT of the other structural materials. This paper summarizes some of the most common non-destructive test methods for deep foundations and presents a new method called the Hilbert Huang Transform (HHT. This Hilbert Huang Transform (HHT method is used now by a wide range in a different health monitoring of many systems. In this paper, some field tests on the timber Piles of one bridge at North Carolina was performed to verify the using the (HHT method for predicting the embedded depth of the unknown piles. Percentage of the accuracy achieved using HHT method for pile length compared to the actual pile length data was performed. Finally, a recommendation is presented for the limitation of using this new method as a new non-destructive method for deep foundations.

  1. Notes on testing equality and interval estimation in Poisson frequency data under a three-treatment three-period crossover trial.

    Science.gov (United States)

    Lui, Kung-Jong; Chang, Kuang-Chao

    2016-10-01

    When the frequency of event occurrences follows a Poisson distribution, we develop procedures for testing equality of treatments and interval estimators for the ratio of mean frequencies between treatments under a three-treatment three-period crossover design. Using Monte Carlo simulations, we evaluate the performance of these test procedures and interval estimators in various situations. We note that all test procedures developed here can perform well with respect to Type I error even when the number of patients per group is moderate. We further note that the two weighted-least-squares (WLS) test procedures derived here are generally preferable to the other two commonly used test procedures in the contingency table analysis. We also demonstrate that both interval estimators based on the WLS method and interval estimators based on Mantel-Haenszel (MH) approach can perform well, and are essentially of equal precision with respect to the average length. We use a double-blind randomized three-treatment three-period crossover trial comparing salbutamol and salmeterol with a placebo with respect to the number of exacerbations of asthma to illustrate the use of these test procedures and estimators. © The Author(s) 2014.

  2. πK-scattering lengths

    International Nuclear Information System (INIS)

    Volkov, M.K.; Osipov, A.A.

    1983-01-01

    The msub(π)asub(0)sup(1/2)=0.1, msub(π)asub(0)sup(3/2)=-0.1, msub(π)asub(0)sup((-))=0.07, msub(π)sup(3)asub(1)sup(1/2)=0.018, msub(π)sup(3)asub(1)aup(3/2)=0.002, msub(π)sup(3)asub(1)sup((-))=0.0044, msub(π)sup(5)asub(2)sup(1/2)=2.4x10sup(-4) and msub(π)sup(5)asub(2)sup(3/2)=-1.2x10sup(-4) scattering lengths are calculated in the framework of the composite meson model which is based on four-quark interaction. The decay form factors of (rho, epsilon, S*) → 2π, (K tilde, K*) → Kπ are used. The q 2 -terms of the quark box diagrams are taken into account. It is shown that the q 2 -terms of the box diagrams give the main contribution to the s-wave scattering lengths. The diagrams with the intermediate vector mesons begin to play the essential role at calculation of the p- and d-wave scattering lengths

  3. Diagnostic pure transgastric NOTES in an intensive therapy unit patient

    Directory of Open Access Journals (Sweden)

    Maciej Michalik

    2011-06-01

    Full Text Available Natural orifice transluminal endoscopic surgery (NOTES is a natural consequence of evolution in minimally invasivesurgery. It allows one to reduce surgical trauma and the number of complications and to improve cosmetic outcomes.It also shortens the patient’s recovery time. So far there have been only nine NOTES procedures performed in Polandand around 200 NOTES interventions performed worldwide. In this paper a transgastric diagnostic NOTES procedurein a critically ill patient is described. A 60-year-old male patient with multi-organ failure (circulatory, respiratory andrenal insufficiency, with co-morbid hypothyroidism and diabetes mellitus hospitalized in the intensive therapy unit(ITU with unknown cause of his condition was qualified for transgastric diagnostic NOTES procedure. This interventionrevealed the diagnosis of metastatic neoplastic disease and allowed persistent therapy to be avoided. DiagnosticNOTES in selected patients seems to be a very useful. It provides fast diagnosis with relatively small perioperativetrauma. It is an easy procedure that requires a regular or operative endoscope, one surgeon and an endoscopic nurse.It can be done anywhere, including at the patient’s bedside. It provides specimens for histopathology and speeds updiagnostics and decision making, especially in terminally ill patients.

  4. Calculation of the mean path length of the Epstein frame under non-sinusoidal excitations using the double Epstein method

    International Nuclear Information System (INIS)

    Marketos, Philip; Zurek, Stan; Moses, Anthony J.

    2008-01-01

    This paper discusses the effect of non-sinusoidal excitation on the mean path length of the Epstein frame. Two different steels, a non-oriented (NO) steel and a high-permeability grain-oriented (HGO) electrical steel have been tested under pure sinusoidal and non-sinusoidal excitations and the mean path length of the Epstein frame has been re-calculated. Results indicate that the actual mean path of the Epstein frame depends not only on the material permeability and anisotropy but also on the peak flux density and magnetising frequency. The amount of distortion of the excitation frequency also has an effect on the value of the actual mean path length of the Epstein frame

  5. Materials Knowledge Systems in Python - A Data Science Framework for Accelerated Development of Hierarchical Materials.

    Science.gov (United States)

    Brough, David B; Wheeler, Daniel; Kalidindi, Surya R

    2017-03-01

    There is a critical need for customized analytics that take into account the stochastic nature of the internal structure of materials at multiple length scales in order to extract relevant and transferable knowledge. Data driven Process-Structure-Property (PSP) linkages provide systemic, modular and hierarchical framework for community driven curation of materials knowledge, and its transference to design and manufacturing experts. The Materials Knowledge Systems in Python project (PyMKS) is the first open source materials data science framework that can be used to create high value PSP linkages for hierarchical materials that can be leveraged by experts in materials science and engineering, manufacturing, machine learning and data science communities. This paper describes the main functions available from this repository, along with illustrations of how these can be accessed, utilized, and potentially further refined by the broader community of researchers.

  6. Lifetime and Path Length of the Virtual Particle

    International Nuclear Information System (INIS)

    Lyuboshitz, V.L.; Lyuboshitz, V.V.

    2005-01-01

    The concepts of the lifetime and path length of a virtual particle are introduced. It is shown that, near the mass surface of the real particle, these quantities constitute a 4-vector. At very high energies, the virtual particle can propagate over considerable (even macroscopic) distances. The formulas for the lifetime and path length of an ultrarelativistic virtual electron in the process of bremsstrahlung in the Coulomb field of a nucleus are obtained. The lifetime and path length of the virtual photon at its conversion into an electron-positron pair are discussed. The connection between the path length of the virtual particle and the coherence length (formation length) is analyzed

  7. Editors' note

    Science.gov (United States)

    Denker, Carsten; Feller, Alex; Schmidt, Wolfgang; von der Lühe, Oskar

    2012-11-01

    This topical issue of Astronomische Nachrichten/Astronomical Notes is a collection of reference articles covering the GREGOR solar telescope, its science capabilities, its subsystems, and its dedicated suite of instruments for high-resolution observations of the Sun. Because ground-based telescopes have life spans of several decades, it is only natural that they continuously reinvent themselves. Literally, the GREGOR telescope builds on the foundations of the venerable Gregory-Coudé Telescope (GCT) at Observatorio del Teide, Tenerife, Spain. Acknowledging the fact that new discoveries in observational solar physics are driven by larger apertures to collect more photons and to scrutinize the Sun in finer detail, the GCT was decommissioned and the building was made available to the GREGOR project.

  8. Information, polarization and term length in democracy

    DEFF Research Database (Denmark)

    Schultz, Christian

    2008-01-01

    This paper considers term lengths in a representative democracy where the political issue divides the population on the left-right scale. Parties are ideologically different and better informed about the consequences of policies than voters are. A short term length makes the government more...... accountable, but the re-election incentive leads to policy-distortion as the government seeks to manipulate swing voters' beliefs to make its ideology more popular. This creates a trade-off: A short term length improves accountability but gives distortions. A short term length is best for swing voters when...

  9. Modeling the self-assembly of ordered nanoporous materials

    Energy Technology Data Exchange (ETDEWEB)

    Monson, Peter [Univ. of Massachusetts, Amherst, MA (United States); Auerbach, Scott [Univ. of Massachusetts, Amherst, MA (United States)

    2017-11-13

    This report describes progress on a collaborative project on the multiscale modeling of the assembly processes in the synthesis of nanoporous materials. Such materials are of enormous importance in modern technology with application in the chemical process industries, biomedicine and biotechnology as well as microelectronics. The project focuses on two important classes of materials: i) microporous crystalline materials, such as zeolites, and ii) ordered mesoporous materials. In the first case the pores are part of the crystalline structure, while in the second the structures are amorphous on the atomistic length scale but where surfactant templating gives rise to order on the length scale of 2 - 20 nm. We have developed a modeling framework that encompasses both these kinds of materials. Our models focus on the assembly of corner sharing silica tetrahedra in the presence of structure directing agents. We emphasize a balance between sufficient realism in the models and computational tractibility given the complex many-body phenomena. We use both on-lattice and off-lattice models and the primary computational tools are Monte Carlo simulations with sampling techniques and ensembles appropriate to specific situations. Our modeling approach is the first to capture silica polymerization, nanopore crystallization, and mesopore formation through computer-simulated self assembly.

  10. Decomposing the queue length distribution of processor-sharing models into queue lengths of permanent customer queues

    NARCIS (Netherlands)

    Cheung, S.K.; van den Berg, Hans Leo; Boucherie, Richardus J.

    2005-01-01

    We obtain a decomposition result for the steady state queue length distribution in egalitarian processor-sharing (PS) models. In particular, for an egalitarian PS queue with $K$ customer classes, we show that the marginal queue length distribution for class $k$ factorizes over the number of other

  11. Association between previously identified loci affecting telomere length and coronary heart disease (CHD in Han Chinese population

    Directory of Open Access Journals (Sweden)

    Ding H

    2014-05-01

    Full Text Available Hui Ding,1 Fen Yan,1 Lin-Lin Zhou,2 Xiu-Hai Ji,3 Xin-Nan Gu,1 Zhi-Wei Tang,1 Ru-Hua Chen11Department of Pulmonary Medicine, The Affiliated Yixing People's Hospital, Jiangsu University, Zhenjiang, Jiangsu Province, 2Department of Cardiology, Affiliated Cixi Hospital, Wenzhou Medical University, Wenzhou, Zhejiang Province, 3Department of Oncology, Affiliated Taicang Hospital of Traditional Chinese Medicine, Suzhou, Jiangsu Province, People's Republic of ChinaPurpose: To replicate previously confirmed telomere-length loci in a Chinese Han population with coronary heart disease (CHD, and investigate these loci and the possibility of and age at onset of CHD.Patients and methods: 1514 CHD patients and 2470 normal controls were recruited. Medical data including age, sex, body mass index, lipid profiles, history of hypertension, type 2 diabetes mellitus, and dyslipidemia were collected from all the participants. Seven previously identified single-nucleotide polymorphisms (SNPs related to leucocyte telomere length were genotyped, including rs10936599 in TERC, rs2736100 in TERT, rs7675998 in NAF1, rs9420907 in OBFC1, rs8105767 in ZNF208, rs755017 in RTEL1, and rs11125529 in ACYP2.Results: No significant difference in genotype frequencies from the Hardy–Weinberg equilibrium test was noted for all tested SNPs both in the CHD patients and the normal controls. No polymorphism was observed for rs9420907, and AA genotype was noted in both the CHD patients and the controls. Neither the genotype nor the allele frequencies of rs2736100, rs8105767, rs11125529, and rs2967374 were significantly different between the CHD patients and the normal controls. For rs10936599 and rs755017, statistical difference was found for the allele frequency but not genotype. Distributions of genotype and allele were significantly different between the two groups for rs7675998. The odds ratio for carriers of CHD was 2.127 (95% confidence interval: 1.909–2.370 for the A allele of rs

  12. Inelastic analysis of finite length and depth cracked tubes

    International Nuclear Information System (INIS)

    Reich, M.; Gardner, D.; Prachuktam, S.; Chang, T.Y.

    1977-01-01

    Steam generator tube failure can at times result in reactor safety problems and subsequent premature reactor shutdown. This paper concerns itself with the prediction of the failure pressures for typical PWR steam generator tubes with longitudinal finite length and finite depth cracks. Only local plastic overload failure is considered since the material is non-notch sensitive. Non-linear finite element analyses are carried out to determine the burst pressures of steam generator tubes containing longitudinal cracks located on the outer surface of the tubes. The non-linearities considered herein include elastic-plastic material behaviour and large deformations. A non-proprietary general purpose non-linear finite element program, NFAP was adopted for the analysis. Due to the asymmetric nature of the cracks, two-dimensional as well as three-dimensional finite element analyses, were performed. The analysis clearly shows that for short cracks axial effects play a significant role. For long cracks, they are not important since two-dimensional conditions predominate and failure is governed by circumferential or hoop stress conditions. (Auth.)

  13. [On the notes of the Xinkan Huangdimingtangjiujing (see text for symbol) in the possession of the National Diet Library].

    Science.gov (United States)

    Amano, Yosuke

    2014-12-01

    This paper analyzes the notes of Xinkan huangdimingtangjiujing which are in the possession of the National Diet Library, particularly referring to those notes which include "master said", or "master's theory". Some of those are found in the answers from Manase Dosan (see text for symbol) to Hata Soha (see text for symbol) collected in the Kotei meido kyukyo hushin shosho (see text for symbol) which is the record of the question and answer letters between Manase Dosan and Hata Soha. This research indicates that this volume has a close relation to the acupuncture research of Dosan's or Soha's school. And it indicates that the "master" in the Notes of Xinkan huangdimingtangjiujing refers to Dosan. Acupuncture research has been flourishing since the Edo era and has compiled a lot of volumes on acupuncture. This volume contains some pioneering pieces of this research done in the Azuchi Momoyama era by Dosan and Soha, and is a precious material, showing that some of the state of affairs of the research done in that age still remains today.

  14. Book Notes “Economics and Social Sciences” 1/2018

    DEFF Research Database (Denmark)

    Reisch, Lucia A.

    2018-01-01

    Short notes on 10 different book and anthology publications from 2016 and 2017 in the fields of economics and social science.......Short notes on 10 different book and anthology publications from 2016 and 2017 in the fields of economics and social science....

  15. 77 FR 39662 - Hazardous Materials; Reverse Logistics (RRR)

    Science.gov (United States)

    2012-07-05

    ... logistics providers estimate that up to 7% of an enterprise's gross sales are return costs. The third-party... logistic shipments for hazardous materials? III. Issues To Be Considered As previously noted, the purpose... documentation costs to develop and maintain risk assessments and operational procedures? If so, what is a fair...

  16. CEBAF Upgrade Bunch Length Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, Mahmoud [Old Dominion Univ., Norfolk, VA (United States)

    2016-05-01

    Many accelerators use short electron bunches and measuring the bunch length is important for efficient operations. CEBAF needs a suitable bunch length because bunches that are too long will result in beam interruption to the halls due to excessive energy spread and beam loss. In this work, bunch length is measured by invasive and non-invasive techniques at different beam energies. Two new measurement techniques have been commissioned; a harmonic cavity showed good results compared to expectations from simulation, and a real time interferometer is commissioned and first checkouts were performed. Three other techniques were used for measurements and comparison purposes without modifying the old procedures. Two of them can be used when the beam is not compressed longitudinally while the other one, the synchrotron light monitor, can be used with compressed or uncompressed beam.

  17. Keeping disease at arm's length

    DEFF Research Database (Denmark)

    Lassen, Aske Juul

    2015-01-01

    active ageing change everyday life with chronic disease, and how do older people combine an active life with a range of chronic diseases? The participants in the study use activities to keep their diseases at arm’s length, and this distancing of disease at the same time enables them to engage in social...... and physical activities at the activity centre. In this way, keeping disease at arm’s length is analysed as an ambiguous health strategy. The article shows the importance of looking into how active ageing is practised, as active ageing seems to work well in the everyday life of the older people by not giving...... emphasis to disease. The article is based on ethnographic fieldwork and uses vignettes of four participants to show how they each keep diseases at arm’s length....

  18. Distillation of solid carbonaceous material

    Energy Technology Data Exchange (ETDEWEB)

    Burney, C D

    1918-08-31

    A method of distilling carbonaceous material at low or moderate temperatures is described in which the main supply of gases for heating the material under treatment is generated in a combustion chamber located externally of the retort chamber from which combustion chamber the gases are withdrawn and passed under control through hollow elements located within the retort chamber in such manner as to insure the production of the desired temperature gradient along the length of the retort, the said elements being so constructed that they serve to bring the heating gases into indirect contact with the material undergoing treatment while also moving the material progressively through the retort in the opposite direction to that in which the heating gases flow.

  19. 7 CFR 1901.508 - Servicing of insured notes outstanding with investors.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 12 2010-01-01 2010-01-01 false Servicing of insured notes outstanding with investors. 1901.508 Section 1901.508 Agriculture Regulations of the Department of Agriculture (Continued) RURAL... Ownership and Insured Notes § 1901.508 Servicing of insured notes outstanding with investors. The Director...

  20. Determining Recovery Potential of Dredged Material for Beneficial Use - Site Characterization; Prescriptive Approach

    National Research Council Canada - National Science Library

    Olin-Estes, Trudy

    2000-01-01

    ... of physical separation. The first technical note(Olin-Estes and Palermo 2000) introduces physical separation concepts and presents mathematical relationships for estimating material recovery potential (MRP...

  1. A Guide to Field Notes for Qualitative Research: Context and Conversation.

    Science.gov (United States)

    Phillippi, Julia; Lauderdale, Jana

    2018-02-01

    Field notes are widely recommended in qualitative research as a means of documenting needed contextual information. With growing use of data sharing, secondary analysis, and metasynthesis, field notes ensure rich context persists beyond the original research team. However, while widely regarded as essential, there is not a guide to field note collection within the literature to guide researchers. Using the qualitative literature and previous research experience, we provide a concise guide to collection, incorporation, and dissemination of field notes. We provide a description of field note content for contextualization of an entire study as well as individual interviews and focus groups. In addition, we provide two "sketch note" guides, one for study context and one for individual interviews or focus groups for use in the field. Our guides are congruent with many qualitative and mixed methodologies and ensure contextual information is collected, stored, and disseminated as an essential component of ethical, rigorous qualitative research.

  2. Effect of heated length on the Critical Heat Flux of subcooled flow boiling. 2. Effective heated length under axially nonuniform heating condition

    International Nuclear Information System (INIS)

    Kinoshita, Hidetaka; Yoshida, Takuya; Nariai, Hideki; Inasaka, Fujio

    1998-01-01

    Effect of heated length on the Critical Heat Flux (CHF) of subcooled flow boiling with water was experimentally investigated by using direct current heated tube made of stainless steel a part of whose wall thickness was axially cut for realizing nonuniform heat flux condition. The higher enhancement of the CHF was derived for shorter tube length. The effective heated length was determined for the tube under axially nonuniform heat flux condition. When the lower heat flux part below the Net Vapor Generation (NVG) heat flux exists at the middle of tube length, then the effective heated length becomes the tube length downstream the lower heat flux parts. However, when the lower heat flux part is above the NVG, then the effective heated length is full tube length. (author)

  3. The relationship of protein conservation and sequence length

    Directory of Open Access Journals (Sweden)

    Panchenko Anna R

    2002-11-01

    Full Text Available Abstract Background In general, the length of a protein sequence is determined by its function and the wide variance in the lengths of an organism's proteins reflects the diversity of specific functional roles for these proteins. However, additional evolutionary forces that affect the length of a protein may be revealed by studying the length distributions of proteins evolving under weaker functional constraints. Results We performed sequence comparisons to distinguish highly conserved and poorly conserved proteins from the bacterium Escherichia coli, the archaeon Archaeoglobus fulgidus, and the eukaryotes Saccharomyces cerevisiae, Drosophila melanogaster, and Homo sapiens. For all organisms studied, the conserved and nonconserved proteins have strikingly different length distributions. The conserved proteins are, on average, longer than the poorly conserved ones, and the length distributions for the poorly conserved proteins have a relatively narrow peak, in contrast to the conserved proteins whose lengths spread over a wider range of values. For the two prokaryotes studied, the poorly conserved proteins approximate the minimal length distribution expected for a diverse range of structural folds. Conclusions There is a relationship between protein conservation and sequence length. For all the organisms studied, there seems to be a significant evolutionary trend favoring shorter proteins in the absence of other, more specific functional constraints.

  4. Stochasticity in materials structure, properties, and processing—A review

    Science.gov (United States)

    Hull, Robert; Keblinski, Pawel; Lewis, Dan; Maniatty, Antoinette; Meunier, Vincent; Oberai, Assad A.; Picu, Catalin R.; Samuel, Johnson; Shephard, Mark S.; Tomozawa, Minoru; Vashishth, Deepak; Zhang, Shengbai

    2018-03-01

    We review the concept of stochasticity—i.e., unpredictable or uncontrolled fluctuations in structure, chemistry, or kinetic processes—in materials. We first define six broad classes of stochasticity: equilibrium (thermodynamic) fluctuations; structural/compositional fluctuations; kinetic fluctuations; frustration and degeneracy; imprecision in measurements; and stochasticity in modeling and simulation. In this review, we focus on the first four classes that are inherent to materials phenomena. We next develop a mathematical framework for describing materials stochasticity and then show how it can be broadly applied to these four materials-related stochastic classes. In subsequent sections, we describe structural and compositional fluctuations at small length scales that modify material properties and behavior at larger length scales; systems with engineered fluctuations, concentrating primarily on composite materials; systems in which stochasticity is developed through nucleation and kinetic phenomena; and configurations in which constraints in a given system prevent it from attaining its ground state and cause it to attain several, equally likely (degenerate) states. We next describe how stochasticity in these processes results in variations in physical properties and how these variations are then accentuated by—or amplify—stochasticity in processing and manufacturing procedures. In summary, the origins of materials stochasticity, the degree to which it can be predicted and/or controlled, and the possibility of using stochastic descriptions of materials structure, properties, and processing as a new degree of freedom in materials design are described.

  5. Lecture notes on ideal magnetohydrodynamics

    International Nuclear Information System (INIS)

    Goedbloed, J.P.

    1983-03-01

    Notes, prepared for a course of lectures held at the Instituto de Fisica, Universidade Estadual de Campinas, Brazil (June-August 1978). An extensive theoretical treatment of the behaviour of hot plasmas caught in equations and mathematical models is presented in 12 chapters

  6. Writing and Music: Album Liner Notes

    Directory of Open Access Journals (Sweden)

    Dean Leonard Biron

    2011-09-01

    Full Text Available A deceptive aspect of the ‘writing about music is like dancing about architecture’ cliché is the function of the preposition ‘about’. Literature and music, dance and architecture, painting and film – all are discrete aesthetic forms that nonetheless simultaneously feed off and provide nourishment for each other as part of art’s perpetual drive toward diversity and innovation. Nowhere is the aptness of the association between writing and music more obvious than in the phenomenon of album liner notes. Rather than merely an attempt at describing or translating musical experience, liner notes contribute to the dialogue between composer and listener and are a significant part of the culture of contemporary music.

  7. Effect of canal length and curvature on working length alteration with WaveOne reciprocating files.

    Science.gov (United States)

    Berutti, Elio; Chiandussi, Giorgio; Paolino, Davide Salvatore; Scotti, Nicola; Cantatore, Giuseppe; Castellucci, Arnaldo; Pasqualini, Damiano

    2011-12-01

    This study evaluated the working length (WL) modification after instrumentation with WaveOne Primary (Dentsply Maillefer, Ballaigues, Switzerland) reciprocating files and the incidence of overinstrumentation in relation to the initial WL. Thirty-two root canals of permanent teeth were used. The angles of curvature of the canals were calculated on digital radiographs. The initial WL with K-files was transferred to the matched WaveOne Primary reciprocating files. After glide paths were established with PathFile (Dentsply Maillefer, Ballaigues, Switzerland), canals were shaped with WaveOne Primary referring to the initial WL. The difference between the postinstrumentation canal length and the initial canal length was analyzed by using a fiberoptic inspection microscope. Data were analyzed with a balanced 2-way factorial analysis of variance (P < .05). Referring to the initial WL, 24 of 32 WaveOne Primary files projected beyond the experimental apical foramen (minimum-maximum, 0.14-0.76 mm). A significant decrease in the canal length after instrumentation (95% confidence interval ranging from -0.34 mm to -0.26 mm) was detected. The canal curvature significantly influenced the WL variation (F(1) = 30.65, P < .001). The interaction between the initial canal length and the canal curvature was statistically significant (F(2) = 4.38, P = .014). Checking the WL before preparation of the apical third of the root canal is recommended when using the new WaveOne NiTi single-file system. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  8. Maternal telomere length inheritance in the king penguin.

    Science.gov (United States)

    Reichert, S; Rojas, E R; Zahn, S; Robin, J-P; Criscuolo, F; Massemin, S

    2015-01-01

    Telomeres are emerging as a biomarker for ageing and survival, and are likely important in shaping life-history trade-offs. In particular, telomere length with which one starts in life has been linked to lifelong survival, suggesting that early telomere dynamics are somehow related to life-history trajectories. This result highlights the importance of determining the extent to which telomere length is inherited, as a crucial factor determining early life telomere length. Given the scarcity of species for which telomere length inheritance has been studied, it is pressing to assess the generality of telomere length inheritance patterns. Further, information on how this pattern changes over the course of growth in individuals living under natural conditions should provide some insight on the extent to which environmental constraints also shape telomere dynamics. To fill this gap partly, we followed telomere inheritance in a population of king penguins (Aptenodytes patagonicus). We tested for paternal and maternal influence on chick initial telomere length (10 days old after hatching), and how these relationships changed with chick age (at 70, 200 and 300 days old). Based on a correlative approach, offspring telomere length was positively associated with maternal telomere length early in life (at 10 days old). However, this relationship was not significant at older ages. These data suggest that telomere length in birds is maternally inherited. Nonetheless, the influence of environmental conditions during growth remained an important factor shaping telomere length, as the maternal link disappeared with chicks' age.

  9. Allometric relationships among body mass, MUZZLE-tail length, and tibia length during the growth of Wistar rats.

    Science.gov (United States)

    Santiago, Hildemberg Agostinho Rocha de; De Pierro, Lucas Rodolfo; Reis, Rafael Menezes; Caluz, Antônio Gabriel Ricardo Engracia; Ribeiro, Victor Barbosa; Volpon, José Batista

    2015-11-01

    To investigate allometric relationships among body mass (BM), muzzle-tail length (MTL), and tibia length (TL) in Wistar rats and establish their growth rate change parameters. Eighteen male and 18 female Wistar rats were studied from the 3rd to the 21st week of age. BM, MTL, and TL were measured daily, and relative growth was compared using allometry. A positive correlation between BM and MTL (p<0.05) and BM and TL (p<0.05) was observed. Males and females showed comparable curves; however, females had turning points at a younger age. The allometric relationship between BM and MTL presented a regular increase until reaching a mass of 351 g (males) and 405 g (females). BM and TL showed an initial increase until 185 g (males) and 182 g (females), and then reached a plateau that finished at 412 g (males) and 334 g (females), to display another increase. The allometric relationship of body mass with animal length and tibia length was comparable for male and female rats, with female rats maturing earlier. Animal longitudinal growth occurred in a single stage. In contrast, tibia length depicted two stages of accelerated growth with an intermediate period of deceleration.

  10. Profiling Chilean Suicide Note-Writers through Content Analysis

    Directory of Open Access Journals (Sweden)

    Francisco Ceballos-Espinoza

    2016-09-01

    Full Text Available Suicides account for 2000 deaths in Chile each year. With a suicide rate of 11.3, it is classified as a country with high suicide risk. Aims: to identify personality and cognitive characteristics of the group of Chilean suicides that left suicide notes, through a content analysis. Methods: descriptive field study with an ex post facto design. All suicides registered between 2010 and 2012 by the Investigations Police of Chile were analyzed, obtaining 203 suicide notes from 96 cases. The Darbonne categories for content analysis were used with the inter-judge method. Results: The mean age of the suicides was 44.2 (SD = 18.53. Most of the notes were addressed to family members (51.7%. The most expressed reasons were marital- or interpersonal-related (24.6%; another 23.6% expressed a lack of purpose or hopelessness (including depression, wish to die, low self-esteem. The most frequent content expressed were instructions (about money, children, and funeral. All of the notes showed logical thinking and were written with coherence and clarity. Notably 42% of the notes were marked by affections of fondness, love or dependence of others. Regarding attitudes, the most common were of escape or farewell (42.4%, followed by fatalism, hopelessness, frustration or tiredness (40%. 24 statistically significant differences were found throughout the categories of analysis, according to cohorts of age, marital status and sex. Conclusions: the findings contribute to the profiling of Chilean suicides and to the implementation of suicide prevention programs

  11. The Minnesota notes on Jordan algebras and their applications

    CERN Document Server

    Walcher, Sebastian

    1999-01-01

    This volume contains a re-edition of Max Koecher's famous Minnesota Notes. The main objects are homogeneous, but not necessarily convex, cones. They are described in terms of Jordan algebras. The central point is a correspondence between semisimple real Jordan algebras and so-called omega-domains. This leads to a construction of half-spaces which give an essential part of all bounded symmetric domains. The theory is presented in a concise manner, with only elementary prerequisites. The editors have added notes on each chapter containing an account of the relevant developments of the theory since these notes were first written.

  12. Detecting clinically relevant new information in clinical notes across specialties and settings.

    Science.gov (United States)

    Zhang, Rui; Pakhomov, Serguei V S; Arsoniadis, Elliot G; Lee, Janet T; Wang, Yan; Melton, Genevieve B

    2017-07-05

    Automated methods for identifying clinically relevant new versus redundant information in electronic health record (EHR) clinical notes is useful for clinicians and researchers involved in patient care and clinical research, respectively. We evaluated methods to automatically identify clinically relevant new information in clinical notes, and compared the quantity of redundant information across specialties and clinical settings. Statistical language models augmented with semantic similarity measures were evaluated as a means to detect and quantify clinically relevant new and redundant information over longitudinal clinical notes for a given patient. A corpus of 591 progress notes over 40 inpatient admissions was annotated for new information longitudinally by physicians to generate a reference standard. Note redundancy between various specialties was evaluated on 71,021 outpatient notes and 64,695 inpatient notes from 500 solid organ transplant patients (April 2015 through August 2015). Our best method achieved at best performance of 0.87 recall, 0.62 precision, and 0.72 F-measure. Addition of semantic similarity metrics compared to baseline improved recall but otherwise resulted in similar performance. While outpatient and inpatient notes had relatively similar levels of high redundancy (61% and 68%, respectively), redundancy differed by author specialty with mean redundancy of 75%, 66%, 57%, and 55% observed in pediatric, internal medicine, psychiatry and surgical notes, respectively. Automated techniques with statistical language models for detecting redundant versus clinically relevant new information in clinical notes do not improve with the addition of semantic similarity measures. While levels of redundancy seem relatively similar in the inpatient and ambulatory settings in the Fairview Health Services, clinical note redundancy appears to vary significantly with different medical specialties.

  13. Developing INDCs: a guidance note

    DEFF Research Database (Denmark)

    Bakkegaard, Riyong Kim; Bee, Skylar; Naswa, Prakriti

    needs and low capability, would need means of implementation (MoI) for adaptation and to take ambitious mitigation actions. Developing countries would include MoI needs in the context of mitigation and adaptation. The note explains briefly how countries can identify their unconditional contributions....

  14. Churchill on Stalin: A note.

    NARCIS (Netherlands)

    Ellman, M.J.

    2006-01-01

    The purpose of this note is to draw attention to two limitations of Churchill's war memoirs as a source of accurate information about Stalin, his views ans actions. they concern, first Stalin's alleged remarks in 1942 about collectivisation, and second Stalin's allleged response to Churchill's

  15. Integration of length and curvature in haptic perception.

    Science.gov (United States)

    Panday, Virjanand; Tiest, Wouter M Bergmann; Kappers, Astrid M L

    2014-01-24

    We investigated if and how length and curvature information are integrated when an object is explored in one hand. Subjects were asked to explore four types of objects between thumb and index finger. Objects differed in either length, curvature, both length and curvature correlated as in a circle, or anti-correlated. We found that when both length and curvature are present, performance is significantly better than when only one of the two cues is available. Therefore, we conclude that there is integration of length and curvature. Moreover, if the two cues are correlated in a circular cross-section instead of in an anti-correlated way, performance is better than predicted by a combination of two independent cues. We conclude that integration of curvature and length is highly efficient when the cues in the object are combined as in a circle, which is the most common combination of curvature and length in daily life.

  16. Communications received from Member States regarding guidelines for the export of nuclear material, equipment and technology

    International Nuclear Information System (INIS)

    1994-04-01

    The Director General has received notes verbales to the export of nuclear material, equipment and technology from the following Permanent Missions to the International Atomic Energy Agency: notes verbales dated 1 March 1994 from the Permanent Missions of Australia, Austria, Belgium, Bulgaria, Canada, the Czech Republic, Denmark, Finland, France, Germany, Hungary, Italy, Japan, the Netherlands, Poland, Portugal, Spain, Sweden, Switzerland, the United Kingdom of Great Britain and Northern Ireland, the United States of America; and a note verbale dated 12 March 1994 from the Permanent Mission of Romania. The purpose of these notes verbales is to provide further information on these Governments' nuclear export policies and practices

  17. Illicit diversion of nuclear materials

    International Nuclear Information System (INIS)

    Bett, F.L.

    1975-08-01

    This paper discusses the means of preventing illegal use of nuclear material by terrorists or other sub-national groups and by governments. With respect to sub-national groups, it concludes that the preventive measures of national safeguards systems, when taken together with the practical difficulties of using nuclear material, would make the diversion and illegal use of nuclear material unattractive in comparison with other avenues open to these groups to attain their ends. It notes that there are only certain areas in the nuclear fuel cycle, e.g. production of some types of nuclear fuel embodying highly enriched uranium and shipment of strategically significant nuclear material, which contain material potentially useful to these groups. It also discusses the difficult practical problems, e.g. coping with radiation, which would face the groups in making use of the materials for terrorist purposes. Concerning illegal use by Governments, the paper describes the role of international safeguards, as applied by the International Atomic Energy Agency, and the real deterrent effect of these safeguards which is achieved through the requirements to maintain comprehensive operating records of the use of nuclear material and by regular inspections to verify these records. The paper makes the point that Australia would not consider supplying nuclear material unless it were subject to international safeguards. (author)

  18. Identification of documented medication non-adherence in physician notes.

    Science.gov (United States)

    Turchin, Alexander; Wheeler, Holly I; Labreche, Matthew; Chu, Julia T; Pendergrass, Merri L; Einbinder, Jonathan S; Einbinder, Jonathan Seth

    2008-11-06

    Medication non-adherence is common and the physicians awareness of it may be an important factor in clinical decision making. Few sources of data on physician awareness of medication non-adherence are available. We have designed an algorithm to identify documentation of medication non-adherence in the text of physician notes. The algorithm recognizes eight semantic classes of documentation of medication non-adherence. We evaluated the algorithm against manual ratings of 200 randomly selected notes of hypertensive patients. The algorithm detected 89% of the notes with documented medication non-adherence with specificity of 84.7% and positive predictive value of 80.2%. In a larger dataset of 1,000 documents, notes that documented medication non-adherence were more likely to report significantly elevated systolic (15.3% vs. 9.0%; p = 0.002) and diastolic (4.1% vs. 1.9%; p = 0.03) blood pressure. This novel clinically validated tool expands the range of information on medication non-adherence available to researchers.

  19. Note onset deviations as musical piece signatures.

    Science.gov (United States)

    Serrà, Joan; Özaslan, Tan Hakan; Arcos, Josep Lluis

    2013-01-01

    A competent interpretation of a musical composition presents several non-explicit departures from the written score. Timing variations are perhaps the most important ones: they are fundamental for expressive performance and a key ingredient for conferring a human-like quality to machine-based music renditions. However, the nature of such variations is still an open research question, with diverse theories that indicate a multi-dimensional phenomenon. In the present study, we consider event-shift timing variations and show that sequences of note onset deviations are robust and reliable predictors of the musical piece being played, irrespective of the performer. In fact, our results suggest that only a few consecutive onset deviations are already enough to identify a musical composition with statistically significant accuracy. We consider a mid-size collection of commercial recordings of classical guitar pieces and follow a quantitative approach based on the combination of standard statistical tools and machine learning techniques with the semi-automatic estimation of onset deviations. Besides the reported results, we believe that the considered materials and the methodology followed widen the testing ground for studying musical timing and could open new perspectives in related research fields.

  20. Note onset deviations as musical piece signatures.

    Directory of Open Access Journals (Sweden)

    Joan Serrà

    Full Text Available A competent interpretation of a musical composition presents several non-explicit departures from the written score. Timing variations are perhaps the most important ones: they are fundamental for expressive performance and a key ingredient for conferring a human-like quality to machine-based music renditions. However, the nature of such variations is still an open research question, with diverse theories that indicate a multi-dimensional phenomenon. In the present study, we consider event-shift timing variations and show that sequences of note onset deviations are robust and reliable predictors of the musical piece being played, irrespective of the performer. In fact, our results suggest that only a few consecutive onset deviations are already enough to identify a musical composition with statistically significant accuracy. We consider a mid-size collection of commercial recordings of classical guitar pieces and follow a quantitative approach based on the combination of standard statistical tools and machine learning techniques with the semi-automatic estimation of onset deviations. Besides the reported results, we believe that the considered materials and the methodology followed widen the testing ground for studying musical timing and could open new perspectives in related research fields.