WorldWideScience

Sample records for legionella pneumophila promotes

  1. Legionella pneumophila-Derived Outer Membrane Vesicles Promote Bacterial Replication in Macrophages.

    Directory of Open Access Journals (Sweden)

    Anna Lena Jung

    2016-04-01

    Full Text Available The formation and release of outer membrane vesicles (OMVs is a phenomenon of Gram-negative bacteria. This includes Legionella pneumophila (L. pneumophila, a causative agent of severe pneumonia. Upon its transmission into the lung, L. pneumophila primarily infects and replicates within macrophages. Here, we analyzed the influence of L. pneumophila OMVs on macrophages. To this end, differentiated THP-1 cells were incubated with increasing doses of Legionella OMVs, leading to a TLR2-dependent classical activation of macrophages with the release of pro-inflammatory cytokines. Inhibition of TLR2 and NF-κB signaling reduced the induction of pro-inflammatory cytokines. Furthermore, treatment of THP-1 cells with OMVs prior to infection reduced replication of L. pneumophila in THP-1 cells. Blocking of TLR2 activation or heat denaturation of OMVs restored bacterial replication in the first 24 h of infection. With prolonged infection-time, OMV pre-treated macrophages became more permissive for bacterial replication than untreated cells and showed increased numbers of Legionella-containing vacuoles and reduced pro-inflammatory cytokine induction. Additionally, miRNA-146a was found to be transcriptionally induced by OMVs and to facilitate bacterial replication. Accordingly, IRAK-1, one of miRNA-146a's targets, showed prolonged activation-dependent degradation, which rendered THP-1 cells more permissive for Legionella replication. In conclusion, L. pneumophila OMVs are initially potent pro-inflammatory stimulators of macrophages, acting via TLR2, IRAK-1, and NF-κB, while at later time points, OMVs facilitate L. pneumophila replication by miR-146a-dependent IRAK-1 suppression. OMVs might thereby promote spreading of L. pneumophila in the host.

  2. Growth regulation of Legionella Pneumophila in biofilms and amoebae; Wachstumsregulation von Legionella Pneumophila in Biofilmen und Amoeben

    Energy Technology Data Exchange (ETDEWEB)

    Hilbi, H.

    2006-07-01

    This final report for the Swiss Federal Office of Energy (SFOE) presents the results of studies made on the regulation of the growth of Legionella Pneumophila bacteria in biofilms and amoebae. In a first project, the formation of biofilms by Legionella Pneumophila bacteria was analysed in static and dynamic systems using a complex growth medium. Under static and dynamic clinical and environmental conditions, the adherence of the biofilms on polystyrene tissue was studied. This was also examined under dynamic flow conditions. In a second part of the project, the regulation of growth of Legionella Pneumophila in amoebae was examined in that changes were made to the genome of the bacteria. The importance of the work for the de-activation of Legionella Pneumophila bacteria in biofilms is noted in the conclusions of the report.

  3. Molecular characterization of Legionella pneumophila-induced interleukin-8 expression in T cells

    Directory of Open Access Journals (Sweden)

    Mukaida Naofumi

    2010-01-01

    Full Text Available Abstract Background Legionella pneumophila is the causative agent of human Legionnaire's disease. During infection, the bacterium invades macrophages and lung epithelial cells, and replicates intracellularly. However, little is known about its interaction with T cells. We investigated the ability of L. pneumophila to infect and stimulate the production of interleukin-8 (IL-8 in T cells. The objective of this study was to assess whether L. pneumophila interferes with the immune system by interacting and infecting T cells. Results Wild-type L. pneumophila and flagellin-deficient Legionella, but not L. pneumophila lacking a functional type IV secretion system Dot/Icm, replicated in T cells. On the other hand, wild-type L. pneumophila and Dot/Icm-deficient Legionella, but not flagellin-deficient Legionella or heat-killed Legionella induced IL-8 expression. L. pneumophila activated an IL-8 promoter through the NF-κB and AP-1 binding regions. Wild-type L. pneumophila but not flagellin-deficient Legionella activated NF-κB, p38 mitogen-activated protein kinase (MAPK, Jun N-terminal kinase (JNK, and transforming growth factor β-associated kinase 1 (TAK1. Transfection of dominant negative mutants of IκBα, IκB kinase, NF-κB-inducing kinase, TAK1, MyD88, and p38 MAPK inhibited L. pneumophila-induced IL-8 activation. Inhibitors of NF-κB, p38 MAPK, and JNK blocked L. pneumophila-induced IL-8 expression. In addition, c-Jun, JunD, cyclic AMP response element binding protein, and activating transcription factor 1, which are substrates of p38 MAPK and JNK, bound to the AP-1 site of the IL-8 promoter. Conclusions Taken together, L. pneumophila induced a flagellin-dependent activation of TAK1, p38 MAPK, and JNK, as well as NF-κB and AP-1, which resulted in IL-8 production in human T cells, presumably contributing to the immune response in Legionnaire's disease.

  4. Clinical Application of a Multiplex Real-Time PCR Assay for Simultaneous Detection of Legionella Species, Legionella pneumophila, and Legionella pneumophila Serogroup 1

    OpenAIRE

    Benitez, Alvaro J.; Winchell, Jonas M.

    2014-01-01

    We developed a single-tube multiplex real-time PCR assay capable of simultaneously detecting and discriminating Legionella spp., Legionella pneumophila, and Legionella pneumophila serogroup 1 in primary specimens. Evaluation of 21 clinical specimens and 115 clinical isolates demonstrated this assay to be a rapid, high-throughput diagnostic test with 100% specificity that may aid during legionellosis outbreaks and epidemiologic investigations.

  5. Isolation of Legionella pneumophila from hotels of Greece.

    Science.gov (United States)

    Alexiou, S D; Antoniadis, A; Papapaganagiotou, J; Stefanou, T

    1989-03-01

    Twenty water samples collected from 6 hotels situated in various areas of Greece were examined for the presence of Legionella pneumophila and Legionella-like organisms. Five of the six hotels included in this investigation were associated with cases of legionellosis. Legionella pneumophila serogroups 1 and 8 were isolated from four of six hotels, mainly from the hot water supply system. This is the first isolation and identification of L. pneumophila in Greece.

  6. Molecular Evolution of the dotA Gene in Legionella pneumophila

    OpenAIRE

    Ko, Kwan Soo; Hong, Seong Karp; Lee, Hae Kyung; Park, Mi-Yeoun; Kook, Yoon-Hoh

    2003-01-01

    The molecular evolution of dotA, which is related to the virulence of Legionella pneumophila, was investigated by comparing the sequences of 15 reference strains (serogroups 1 to 15). It was found that dotA has a complex mosaic structure. The whole dotA gene of Legionella pneumophila subsp. pneumophila serogroups 2, 6, and 12 has been transferred from Legionella pneumophila subsp. fraseri. A discrepancy was found between the trees inferred from the nucleotide and deduced amino acid sequences ...

  7. Ciliate Paramecium is a natural reservoir of Legionella pneumophila

    Science.gov (United States)

    Watanabe, Kenta; Nakao, Ryo; Fujishima, Masahiro; Tachibana, Masato; Shimizu, Takashi; Watarai, Masahisa

    2016-04-01

    Legionella pneumophila, the causative agent of Legionnaires’ disease, replicates within alveolar macrophages and free-living amoebae. However, the lifestyle of L. pneumophila in the environment remains largely unknown. Here we established a novel natural host model of L. pneumophila endosymbiosis using the ciliate Paramecium caudatum. We also identified Legionella endosymbiosis-modulating factor A (LefA), which contributes to the change in life stage from endosymbiosis to host lysis, enabling escape to the environment. We isolated L. pneumophila strains from the environment, and they exhibited cytotoxicity toward P. caudatum and induced host lysis. Acidification of the Legionella-containing vacuole (LCV) was inhibited, and enlarged LCVs including numerous bacteria were observed in P. caudatum infected with L. pneumophila. An isogenic L. pneumophila lefA mutant exhibited decreased cytotoxicity toward P. caudatum and impaired the modification of LCVs, resulting in the establishment of endosymbiosis between them. Our results suggest that L. pneumophila may have a mechanism to switch their endosymbiosis in protistan hosts in the environment.

  8. Multiplication of Legionella pneumophila in unsterilized tap water.

    Science.gov (United States)

    Yee, R B; Wadowsky, R M

    1982-06-01

    Naturally occurring Legionella pneumophila, an environmental isolate which had not been grown on artificial medium, was tested for the ability to multiply in tap water. A showerhead containing L. pneumophila and non-Legionellaceae bacteria was immersed in nonsterile tap water supplying this fixture. Also L. pneumophila and non-Legionellaceae bacteria were sedimented from tap water from a surgical intensive care unit. This bacterial suspension was inoculated into tap water from our laboratory. The legionellae in both suspensions multiplied in the tap water at 32, 37, and 42 degrees C. The non-Legionellaceae bacteria multiplied at 25, 32, and 37 degrees C. A water sample which was collected from the bottom of a hot water tank was found to contain L. pneumophila and non-Legionellaceae bacteria. These legionellae also multiplied when the water sample was incubated at 37 degrees C. These results indicate that L. pneumophila may multiply in warm water environments such as hot water plumbing fixtures, hot water tanks, and cooling towers.

  9. Photoreactivation of UV-irradiated Legionella pneumophila and other Legionella species

    International Nuclear Information System (INIS)

    Knudson, G.B.

    1985-01-01

    Shortwave UV light was assessed as a feasible modality for the control of Legionnaires disease bacterium in water. The results of this study show that Legionella pneumophila and six other Legionella species are very sensitive to low doses of UV. However, all Legionella species tested effectively countered the germicidal effect of UV when subsequently exposed to photoreactivating light

  10. Detection of Legionella pneumophila by real-time PCR for the mip gene.

    Science.gov (United States)

    Wilson, Deborah A; Yen-Lieberman, Belinda; Reischl, Udo; Gordon, Steve M; Procop, Gary W

    2003-07-01

    A real-time PCR assay for the mip gene of Legionella pneumophila was tested with 27 isolates of L. pneumophila, 20 isolates of 14 other Legionella species, and 103 non-Legionella bacteria. Eight culture-positive and 40 culture-negative clinical specimens were tested. This assay was 100% sensitive and 100% specific for L. pneumophila.

  11. The Legionella pneumophila Collagen-Like Protein Mediates Sedimentation, Autoaggregation, and Pathogen-Phagocyte Interactions

    Science.gov (United States)

    Abdel-Nour, Mena; Duncan, Carla; Prashar, Akriti; Rao, Chitong; Ginevra, Christophe; Jarraud, Sophie; Low, Donald E.; Ensminger, Alexander W.; Terebiznik, Mauricio R.

    2014-01-01

    Although only partially understood, multicellular behavior is relatively common in bacterial pathogens. Bacterial aggregates can resist various host defenses and colonize their environment more efficiently than planktonic cells. For the waterborne pathogen Legionella pneumophila, little is known about the roles of autoaggregation or the parameters which allow cell-cell interactions to occur. Here, we determined the endogenous and exogenous factors sufficient to allow autoaggregation to take place in L. pneumophila. We show that isolates from Legionella species which do not produce the Legionella collagen-like protein (Lcl) are deficient in autoaggregation. Targeted deletion of the Lcl-encoding gene (lpg2644) and the addition of Lcl ligands impair the autoaggregation of L. pneumophila. In addition, Lcl-induced autoaggregation requires divalent cations. Escherichia coli producing surface-exposed Lcl is able to autoaggregate and shows increased biofilm production. We also demonstrate that L. pneumophila infection of Acanthamoeba castellanii and Hartmanella vermiformis is potentiated under conditions which promote Lcl dependent autoaggregation. Overall, this study shows that L. pneumophila is capable of autoaggregating in a process that is mediated by Lcl in a divalent-cation-dependent manner. It also reveals that Lcl potentiates the ability of L. pneumophila to come in contact, attach, and infect amoebae. PMID:24334670

  12. Exploring the Legionella pneumophila positivity rate in hotel water samples from Antalya, Turkey.

    Science.gov (United States)

    Sepin Özen, Nevgün; Tuğlu Ataman, Şenay; Emek, Mestan

    2017-05-01

    The genus Legionella is a fastidious Gram-negative bacteria widely distributed in natural waters and man made water supply systems. Legionella pneumophila is the aetiological agent of approximately 90% of reported Legionellosis cases, and serogroup 1 is the most frequent cause of infections. Legionnaires' disease is often associated with travel and continues to be a public health concern at present. The correct water management quality practices and rapid methods for analyzing Legionella species in environmental water is a key point for the prevention of Legionnaires' disease outbreaks. This study aimed to evaluate the positivity rates and serotyping of Legionella species from water samples in the region of Antalya, Turkey, which is an important tourism center. During January-December 2010, a total of 1403 samples of water that were collected from various hotels (n = 56) located in Antalya were investigated for Legionella pneumophila. All samples were screened for L. pneumophila by culture method according to "ISO 11731-2" criteria. The culture positive Legionella strains were serologically identified by latex agglutination test. A total of 142 Legionella pneumophila isolates were recovered from 21 (37.5%) of 56 hotels. The total frequency of L. pneumophila isolation from water samples was found as 10.1%. Serological typing of 142 Legionella isolates by latex agglutination test revealed that strains belonging to L. pneumophila serogroups 2-14 predominated in the examined samples (85%), while strains of L. pneumophila serogroup 1 were less numerous (15%). According to our knowledge, our study with the greatest number of water samples from Turkey demonstrates that L. pneumophila serogroups 2-14 is the most common isolate. Rapid isolation of L. pneumophila from environmental water samples is essential for the investigation of travel related outbreaks and the possible resources. Further studies are needed to have epidemiological data and to determine the types of L

  13. Spatial distribution of Legionella pneumophila MLVA-genotypes in a drinking water system.

    Science.gov (United States)

    Rodríguez-Martínez, Sarah; Sharaby, Yehonatan; Pecellín, Marina; Brettar, Ingrid; Höfle, Manfred; Halpern, Malka

    2015-06-15

    Bacteria of the genus Legionella cause water-based infections, resulting in severe pneumonia. To improve our knowledge about Legionella spp. ecology, its prevalence and its relationships with environmental factors were studied. Seasonal samples were taken from both water and biofilm at seven sampling points of a small drinking water distribution system in Israel. Representative isolates were obtained from each sample and identified to the species level. Legionella pneumophila was further determined to the serotype and genotype level. High resolution genotyping of L. pneumophila isolates was achieved by Multiple-Locus Variable number of tandem repeat Analysis (MLVA). Within the studied water system, Legionella plate counts were higher in summer and highly variable even between adjacent sampling points. Legionella was present in six out of the seven selected sampling points, with counts ranging from 1.0 × 10(1) to 5.8 × 10(3) cfu/l. Water counts were significantly higher in points where Legionella was present in biofilms. The main fraction of the isolated Legionella was L. pneumophila serogroup 1. Serogroup 3 and Legionella sainthelensis were also isolated. Legionella counts were positively correlated with heterotrophic plate counts at 37 °C and negatively correlated with chlorine. Five MLVA-genotypes of L. pneumophila were identified at different buildings of the sampled area. The presence of a specific genotype, "MLVA-genotype 4", consistently co-occurred with high Legionella counts and seemed to "trigger" high Legionella counts in cold water. Our hypothesis is that both the presence of L. pneumophila in biofilm and the presence of specific genotypes, may indicate and/or even lead to high Legionella concentration in water. This observation deserves further studies in a broad range of drinking water systems to assess its potential for general use in drinking water monitoring and management. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Severe Pneumonia Caused by Legionella pneumophila: Differential Diagnosis and Therapeutic Considerations.

    Science.gov (United States)

    Chahin, Abdullah; Opal, Steven M

    2017-03-01

    Severe legionella pneumonia poses a diagnostic challenge and requires early intervention. Legionnaire's disease can have several presenting signs, symptoms, and laboratory abnormalities that suggest that Legionella pneumophila is the pathogen, but none of these are sufficient to distinguish L pneumophila pneumonia from other respiratory pathogens. L pneumophila is primarily an intracellular pathogen and needs treatment with antibiotics that efficiently enter the intracellular space. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. The Legionella pneumophila GIG operon responds to gold and copper in planktonic and biofilm cultures.

    Science.gov (United States)

    Jwanoswki, Kathleen; Wells, Christina; Bruce, Terri; Rutt, Jennifer; Banks, Tabitha; McNealy, Tamara L

    2017-01-01

    Legionella pneumophila contaminates man-made water systems and creates numerous exposure risks for Legionnaires' Disease. Because copper/silver ionization is commonly used to control L. pneumophila, its mechanisms of metal response and detoxification are of significant interest. Here we describe an L. pneumophila operon with significant similarity to the GIG operon of Cupriavidus metallidurans. The Legionella GIG operon is present in a subset of strains and has been acquired as part of the ICE-βox 65-kB integrative conjugative element. We assessed GIG promoter activity following exposure of L. pneumophila to multiple concentrations of HAuCl4, CuSO4 and AgNO3. At 37°C, control stationary phase cultures exhibited GIG promoter activity. This activity increased significantly in response to 20 and 50uM HAuCl4 and CuSO4 but not in response to AgNO3. Conversely, at 26°C, cultures exhibited decreased promoter response to copper. GIG promoter activity was also induced by HAuCl4 or CuSO4 during early biofilm establishment at both temperatures. When an L. pneumophila GIG promoter construct was transformed into E. coli DH5α, cultures showed baseline expression levels that did not increase following metal addition. Analysis of L. pneumophila transcriptional regulatory mutants suggested that GIG up-regulation in the presence of metal ions may be influenced by the stationary phase sigma factor, RpoS.

  16. The Legionella pneumophila GIG operon responds to gold and copper in planktonic and biofilm cultures.

    Directory of Open Access Journals (Sweden)

    Kathleen Jwanoswki

    Full Text Available Legionella pneumophila contaminates man-made water systems and creates numerous exposure risks for Legionnaires' Disease. Because copper/silver ionization is commonly used to control L. pneumophila, its mechanisms of metal response and detoxification are of significant interest. Here we describe an L. pneumophila operon with significant similarity to the GIG operon of Cupriavidus metallidurans. The Legionella GIG operon is present in a subset of strains and has been acquired as part of the ICE-βox 65-kB integrative conjugative element. We assessed GIG promoter activity following exposure of L. pneumophila to multiple concentrations of HAuCl4, CuSO4 and AgNO3. At 37°C, control stationary phase cultures exhibited GIG promoter activity. This activity increased significantly in response to 20 and 50uM HAuCl4 and CuSO4 but not in response to AgNO3. Conversely, at 26°C, cultures exhibited decreased promoter response to copper. GIG promoter activity was also induced by HAuCl4 or CuSO4 during early biofilm establishment at both temperatures. When an L. pneumophila GIG promoter construct was transformed into E. coli DH5α, cultures showed baseline expression levels that did not increase following metal addition. Analysis of L. pneumophila transcriptional regulatory mutants suggested that GIG up-regulation in the presence of metal ions may be influenced by the stationary phase sigma factor, RpoS.

  17. First Case of Legionnaire's Disease Caused by Legionella anisa in Spain and the Limitations on the Diagnosis of Legionella non-pneumophila Infections.

    Science.gov (United States)

    Vaccaro, Lucianna; Izquierdo, Fernando; Magnet, Angela; Hurtado, Carolina; Salinas, Mireya B; Gomes, Thiago Santos; Angulo, Santiago; Salso, Santiago; Pelaez, Jesús; Tejeda, Maria Isabel; Alhambra, Almudena; Gómez, Carmen; Enríquez, Ana; Estirado, Eva; Fenoy, Soledad; Del Aguila, Carmen

    2016-01-01

    Legionnaires' disease is a severe form of pneumonia, with worldwide relevance, caused by Legionella spp. Approximately 90% of all cases of legionellosis are caused by Legionella pneumophila, but other species can also be responsible for this infection. These bacteria are transmitted by inhalation of aerosols or aspiration of contaminated water. In Spain, environmental studies have demonstrated the presence of Legionella non-pneumophila species in drinking water treatment plants and water distribution networks. Aware that this evidence indicates a risk factor and the lack of routine assays designed to detect simultaneously diverse Legionella species, we analyzed 210 urine samples from patients presenting clinical manifestations of pneumonia using a semi-nested PCR for partial amplification of the 16S rDNA gene of Legionella and a diagnostic method used in hospitals for Legionella antigen detection. In this study, we detected a total of 15 cases of legionellosis (7.1%) and the first case of Legionnaires' disease caused by L. anisa in Spain. While the conventional method used in hospitals could only detect four cases (1.9%) produced by L. pneumophila serogroup 1, using PCR, the following species were identified: Legionella spp. (10/15), L. pneumophila (4/15) and L. anisa (1/15). These results suggest the need to change hospital diagnostic strategies regarding the identification of Legionella species associated with this disease. Therefore, the detection of Legionella DNA by PCR in urine samples seems to be a suitable alternative method for a sensitive, accurate and rapid diagnosis of Legionella pneumonia, caused by L. pneumophila and also for L. non-pneumophila species.

  18. Presence and Persistence of Viable, Clinically Relevant Legionella pneumophila Bacteria in Garden Soil in the Netherlands

    Science.gov (United States)

    van Heijnsbergen, E.; van Deursen, A.; Bouwknegt, M.; Bruin, J. P.; Schalk, J. A. C.

    2016-01-01

    ABSTRACT Garden soils were investigated as reservoirs and potential sources of pathogenic Legionella bacteria. Legionella bacteria were detected in 22 of 177 garden soil samples (12%) by amoebal coculture. Of these 22 Legionella-positive soil samples, seven contained Legionella pneumophila. Several other species were found, including the pathogenic Legionella longbeachae (4 gardens) and Legionella sainthelensi (9 gardens). The L. pneumophila isolates comprised 15 different sequence types (STs), and eight of these STs were previously isolated from patients according to the European Working Group for Legionella Infections (EWGLI) database. Six gardens that were found to be positive for L. pneumophila were resampled after several months, and in three gardens, L. pneumophila was again isolated. One of these gardens was resampled four times throughout the year and was found to be positive for L. pneumophila on all occasions. IMPORTANCE Tracking the source of infection for sporadic cases of Legionnaires' disease (LD) has proven to be hard. L. pneumophila ST47, the sequence type that is most frequently isolated from LD patients in the Netherlands, is rarely found in potential environmental sources. As L. pneumophila ST47 was previously isolated from a garden soil sample during an outbreak investigation, garden soils were investigated as reservoirs and potential sources of pathogenic Legionella bacteria. The detection of viable, clinically relevant Legionella strains indicates that garden soil is a potential source of Legionella bacteria, and future research should assess the public health implication of the presence of L. pneumophila in garden soil. PMID:27316958

  19. Presence and Persistence of Viable, Clinically Relevant Legionella pneumophila Bacteria in Garden Soil in the Netherlands.

    Science.gov (United States)

    van Heijnsbergen, E; van Deursen, A; Bouwknegt, M; Bruin, J P; de Roda Husman, A M; Schalk, J A C

    2016-09-01

    Garden soils were investigated as reservoirs and potential sources of pathogenic Legionella bacteria. Legionella bacteria were detected in 22 of 177 garden soil samples (12%) by amoebal coculture. Of these 22 Legionella-positive soil samples, seven contained Legionella pneumophila Several other species were found, including the pathogenic Legionella longbeachae (4 gardens) and Legionella sainthelensi (9 gardens). The L. pneumophila isolates comprised 15 different sequence types (STs), and eight of these STs were previously isolated from patients according to the European Working Group for Legionella Infections (EWGLI) database. Six gardens that were found to be positive for L. pneumophila were resampled after several months, and in three gardens, L. pneumophila was again isolated. One of these gardens was resampled four times throughout the year and was found to be positive for L. pneumophila on all occasions. Tracking the source of infection for sporadic cases of Legionnaires' disease (LD) has proven to be hard. L. pneumophila ST47, the sequence type that is most frequently isolated from LD patients in the Netherlands, is rarely found in potential environmental sources. As L. pneumophila ST47 was previously isolated from a garden soil sample during an outbreak investigation, garden soils were investigated as reservoirs and potential sources of pathogenic Legionella bacteria. The detection of viable, clinically relevant Legionella strains indicates that garden soil is a potential source of Legionella bacteria, and future research should assess the public health implication of the presence of L. pneumophila in garden soil. Copyright © 2016 van Heijnsbergen et al.

  20. Activities of Tigecycline (GAR-936) against Legionella pneumophila In Vitro and in Guinea Pigs with L. pneumophila Pneumonia

    OpenAIRE

    Edelstein, Paul H.; Weiss, William J.; Edelstein, Martha A. C.

    2003-01-01

    The activities of tigecycline (Wyeth Research) against extracellular and intracellular Legionella pneumophila and for the treatment of guinea pigs with L. pneumophila pneumonia were studied. The tigecycline MIC at which 50% of strains are inhibited for 101 different Legionella sp. strains was 4 μg/ml versus 0.125 and 0.25 μg/ml for azithromycin and erythromycin, respectively. Tigecycline was about as active as erythromycin (tested at 1 μg/ml) against the F889 strain of L. pneumophila grown in...

  1. Detection of cell-associated or soluble antigens of Legionella pneumophila serogroups 1 to 6, Legionella bozemanii, Legionella dumoffii, Legionella gormanii, and Legionella micdadei by staphylococcal coagglutination tests.

    OpenAIRE

    Wilkinson, H W; Fikes, B J

    1981-01-01

    Current methods used for the detection of whole-cell isolates of Legionella or for the detection of Legionella soluble antigens are technically impractical for many clinical laboratories. The purpose of this study was to explore practical alternatives. The results showed that whole cell isolates of Legionella pneumophila serogroups 1 to 6, Legionella bozemanii, Legionella dumoffii, Legionella gormanii, and Legionella micdadei were identified specifically by a simple slide agglutination test o...

  2. [The hazards of hospitals and selected public buildings of Legionella pneumophila].

    Science.gov (United States)

    Sikora, Agnieszka; Kozioł-Montewka, Maria; Wójtowicz-Bobin, Małgorzata; Gładysz, Iwona; Dobosz, Paulina

    2013-11-01

    The registered infection and outbreaks of epidemic tend to monitor potential reservoirs of Legionella infection. According to the Act of 29 March 2007 on the requirements for the quality of water intended for human consumption are required to test for the presence and number of Legionella in the water system of hospitals. In case of detection of L. pneumophila serogroup 1 (SG 1) or increased above normal number other serogroups of bacteria it is necessary to eradicate these bacteria from the water system. The aim of this study was to assess the degree of contamination of the water supply system of selected public buildings and analyze the effectiveness of disinfection methods for the elimination of L. pneumophila in hot water systems. The materials for this study were hot and cold water samples which were collected from the water supply system of 23 different objects. Enumeration of Legionella bacteria in water samples was determined by membrane filtration (FM) and/or by surface inoculation methods according to the standards: PN-ISO 11731: 2002: "The quality of the water. Detection and enumeration of Legionella" and PN-EN ISO 11731-2: 2008: "Water quality--Detection and enumeration of Legionella--Part 2: Methodology of membrane filtration for water with a small number of bacteria". L. pneumophila was present in 164 samples of hot water, which accounted for 76.99%. In all tested water samples L. pneumophila SG 2-14 strains were detected. The most virulent strain--L. pneumophila SG 1 was not detected. In examined 23 objects in 12 of L. pneumophila exceed acceptable levels > 100 CFU/100 ml. The presence of L. pneumophila SG 2-14 demonstrated in all examined objects, indicating the risk of infection, and the need for permanent monitoring of the water system supply. The thermal disinfection is the most common, inexpensive, and effective method of control of L. pneumophila used in examined objects, but does not eliminate bacterial biofilm. Disinfection using the filters

  3. Multiplication of Legionella pneumophila in unsterilized tap water.

    OpenAIRE

    Yee, R B; Wadowsky, R M

    1982-01-01

    Naturally occurring Legionella pneumophila, an environmental isolate which had not been grown on artificial medium, was tested for the ability to multiply in tap water. A showerhead containing L. pneumophila and non-Legionellaceae bacteria was immersed in nonsterile tap water supplying this fixture. Also L. pneumophila and non-Legionellaceae bacteria were sedimented from tap water from a surgical intensive care unit. This bacterial suspension was inoculated into tap water from our laboratory....

  4. Necessity and effect of combating Legionella pneumophila in municipal shower systems.

    Directory of Open Access Journals (Sweden)

    Ragnhild Wiik

    Full Text Available The objective was to obtain research-based, holistic knowledge about necessity and effect of practiced measures against L. pneumophila in municipal shower systems in Stavanger, Norway. The effects of hot water treatment and membrane-filtering were investigated and compared to no intervention at all. The studies were done under real-world conditions. Additionally, a surveillance pilot study of municipal showers in Stavanger was performed. The validity of high total plate count (TPC as an indication of L. pneumophila was evaluated. A simplified method, named "dripping method", for detection and quantification of L. pneumophila was developed. The sensitivity of the dripping method is 5 colony-forming units of L. pneumophila/ml. The transference of L. pneumophila from shower water to aerosols was studied. Interviews and observational studies among the stakeholders were done in order to identify patterns of communication and behavior in a Legionella risk perspective. No substantial effects of the measures against L. pneumophila were demonstrated, except for a distally placed membrane filter. No significant positive correlation between TPC and L. pneumophila concentrations were found. L. pneumophila serogroup 2-14 was demonstrated in 21% of the 29 buildings tested in the surveillance pilot. Relatively few cells of L. pneumophila were transferred from shower water to aerosols. Anxiety appeared as the major driving force in the risk governance of Legionella. In conclusion, the risk of acquiring Legionnaires' disease from municipal shower systems is evaluated as low and uncertain. By eliminating ineffective approaches, targeted Legionella risk governance can be practiced. Risk management by surveillance is evaluated as appropriate.

  5. Isolation of Legionella pneumophila from hospital cooling towers in Johor, Malaysia.

    Science.gov (United States)

    Abdul Samad, B H; Suhaili, M R; Baba, N; Rajasekaran, G

    2004-08-01

    Water-based cooling towers and their water supply at two hospitals in Johor were surveyed for the presence Legionella pneumophila. L. pneumophila were grown from 19 (76%) out of 25 collected water samples. One hospital cooling tower was contaminated with L. pneumophila serogroup 1.

  6. Legionella pneumophila lung abscess associated with immune suppression.

    Science.gov (United States)

    Guy, S D; Worth, L J; Thursky, K A; Francis, P A; Slavin, M A

    2011-10-01

    Legionella species are a common cause of community-acquired pneumonia, infrequently complicated by cavitary disease. We describe Legionella pneumophila pneumonia and abscess formation in an immunosuppressed patient receiving corticosteroid therapy for metastatic breast carcinoma. The predisposing role of corticosteroids is discussed and the management of this complication is reviewed. © 2011 The Authors. Internal Medicine Journal © 2011 Royal Australasian College of Physicians.

  7. Fatal coinfection with Legionella pneumophila serogroup 8 and Aspergillus fumigatus.

    Science.gov (United States)

    Guillouzouic, Aurélie; Bemer, Pascale; Gay-Andrieu, Françoise; Bretonnière, Cédric; Lepelletier, Didier; Mahé, Pierre-Joachim; Villers, Daniel; Jarraud, Sophie; Reynaud, Alain; Corvec, Stéphane

    2008-02-01

    Legionella pneumophila is an important cause of community-acquired and nosocomial pneumonia. We report on a patient who simultaneously developed L. pneumophila serogroup 8 pneumonia and Aspergillus fumigatus lung abscesses. Despite appropriate treatments, Aspergillus disease progressed with metastasis. Coinfections caused by L. pneumophila and A. fumigatus remain exceptional. In apparently immunocompetent patients, corticosteroid therapy is a key risk factor for aspergillosis.

  8. Hartmannella vermiformis inhibition of Legionella pneumophila cultivability

    Science.gov (United States)

    Hartmannella vermiformis is frequently isolated from drinking water (DW) and is permissive to Legionella pneumophila intracellular replication. Thus, H. vermiformis may play an important role in the growth and survival potential of such environmental pathogens. In this study, Pag...

  9. Promotion and Rescue of Intracellular Brucella neotomae Replication during Coinfection with Legionella pneumophila.

    Science.gov (United States)

    Kang, Yoon-Suk; Kirby, James E

    2017-05-01

    We established a new Brucella neotomae in vitro model system for study of type IV secretion system-dependent (T4SS) pathogenesis in the Brucella genus. Importantly, B. neotomae is a rodent pathogen, and unlike B. abortus , B. melitensis , and B. suis , B. neotomae has not been observed to infect humans. It therefore can be handled more facilely using biosafety level 2 practices. More particularly, using a series of novel fluorescent protein and lux operon reporter systems to differentially label pathogens and track intracellular replication, we confirmed T4SS-dependent intracellular growth of B. neotomae in macrophage cell lines. Furthermore, B. neotomae exhibited early endosomal (LAMP-1) and late endoplasmic reticulum (calreticulin)-associated phagosome maturation. These findings recapitulate prior observations for human-pathogenic Brucella spp. In addition, during coinfection experiments with Legionella pneumophila , we found that defective intracellular replication of a B. neotomae T4SS virB4 mutant was rescued and baseline levels of intracellular replication of wild-type B. neotomae were significantly stimulated by coinfection with wild-type but not T4SS mutant L. pneumophila Using confocal microscopy, it was determined that intracellular colocalization of B. neotomae and L. pneumophila was required for rescue and that colocalization came at a cost to L. pneumophila fitness. These findings were not completely expected based on known temporal and qualitative differences in the intracellular life cycles of these two pathogens. Taken together, we have developed a new system for studying in vitro Brucella pathogenesis and found a remarkable T4SS-dependent interplay between Brucella and Legionella during macrophage coinfection. Copyright © 2017 American Society for Microbiology.

  10. Virulence properties of the Legionella pneumophila cell envelope

    Directory of Open Access Journals (Sweden)

    Olga eShevchuk

    2011-04-01

    Full Text Available The bacterial envelope plays a crucial role in the pathogenesis of infectious diseases. In this review, we summarize the current knowledge of the structure and molecular composition of the Legionella pneumophila cell envelope. We describe LPS biosynthesis and the biological activities of membrane and periplasmic proteins and discuss their decisive functions during the pathogen-host interaction. In addition to adherence, invasion and intracellular survival of L. pneumophila, special emphasis is laid on iron acquisition, detoxification, key elicitors of the immune response and the diverse functions of outer membrane vesicles. The critical analysis of the literature reveals that the dynamics and phenotypic plasticity of the Legionella cell surface during the different metabolic stages requires more attention in the future.

  11. [Sequence-based typing of enviromental Legionella pneumophila isolates in Guangzhou].

    Science.gov (United States)

    Zhang, Ying; Qu, Pinghua; Zhang, Jian; Chen, Shouyi

    2011-03-01

    To characterize the genes of Legionella pneumophila isolated from different water source in Guangzhou from 2006 to 2009. To genotype the strains by using sequence-based typing (SBT) scheme. In total 44 L. pneumophila strains were identified by SBT with 7 diversifying genes of flaA, asd, mip, pilE, mompS, proA and neuA. Analysis of the amplicons sequence was taken in the European Working Group for Legionella Infections (EWGLI) international SBT database to obtain the allelic profiles and sequence types (STs). Serogroups were typed by latex agglutination test. Data from SBT revealed a high diversity among the strains and ST01 accounts for 30% (13/ 44). Fifteen new STs were discovered from 20 STs and 2 of them were newly assigned (ST887 and ST888) by EWGLI. SBT Phylogenetic tree was generated by SplitsTree and BURST programs. High diversity and specificity were observed of the L. pneumophila strains in Guangzhou. SBT is useful for L. pneumophila genomic study and epidemiological surveillance.

  12. Legionella pneumophila transcriptome during intracellular multiplication in human macrophages

    Directory of Open Access Journals (Sweden)

    Sebastien P Faucher

    2011-04-01

    Full Text Available Legionella pneumophila is the causative agent of Legionnaires’ disease, an acute pulmonary infection. L. pneumophila is able to infect and multiply in both phagocytic protozoa, such as Acanthamoeba castellanii, and mammalian professional phagocytes. The best-known L. pneumophila virulence determinant is the Icm/Dot Type IVB secretion system (TFBSS, which is used to translocate more than 150 effector proteins to host cells. While the transcriptional response of Legionella to the intracellular environment of A. castellanii has been investigated, much less is known about the Legionella transcriptional response inside human macrophages. In this study, the transcriptome of L. pneumophila was monitored during exponential and post-exponential phase in rich AYE broth as well as during infection of human cultured macrophages. This was accomplished with microarrays and an RNA amplification procedure called SCOTS to detect small amounts of mRNA from low numbers of intracellular bacteria. Among the genes induced intracellularly are those involved in amino acid biosynthetic pathways leading to L-arginine, L-histidine and L-proline as well as many transport systems involved in amino acid and iron uptake. Gene involved in catabolism of glycerol is also induced during intracellular growth and could be used as a carbon source. The genes encoding the Icm/Dot system are not differentially expressed inside cells compared to control bacteria grown in rich broth, but the genes encoding several translocated effectors are strongly induced. Moreover, we used the transcriptome data to predict previously unrecognized Icm/Dot effector genes based on their expression pattern and confirmed translocation for three candidates. This study provides a comprehensive view of how L. pneumophila responds to the human macrophage intracellular environment.

  13. Acanthamoeba polyphaga resuscitates viable non-culturable Legionella pneumophila after disinfection.

    Science.gov (United States)

    García, María Teresa; Jones, Snake; Pelaz, Carmen; Millar, Richard D; Abu Kwaik, Yousef

    2007-05-01

    Amoebae are the natural hosts for Legionella pneumophila and play essential roles in bacterial ecology and infectivity to humans. When L. pneumophila colonizes an aquatic installation, it can persist for years despite repeated treatments with disinfectants. We hypothesized that freshwater amoebae play an important role in bacterial resistance to disinfectants, and in subsequent resuscitation of viable non-culturable (VNC) L. pneumophila that results in re-emergence of the disease-causing strain in the disinfected water source. Our work showed that in the absence of Acanthamoeba polyphaga, seven L. pneumophila strains became non-culturable after treatment by 256 p.p.m. of sodium hypochlorite (NaOCl). In contrast, intracellular L. pneumophila within A. polyphaga was resistant to 1024 p.p.m. of NaOCl. In addition, L. pneumophila-infected A. polyphaga exhibited increased resistance to NaOCl. When chlorine-sterilized water samples were co-cultured with A. polyphaga, the non-culturable L. pneumophila were resuscitated and proliferated robustly within A. polyphaga. Upon treatment by NaOCl, uninfected amoebae differentiated into cysts within 48 h. In contrast, L. pneumophila-infected A. polyphaga failed to differentiate into cysts, and L. pneumophila was never detected in cysts of A. polyphaga. We conclude that amoebic trophozoites protect intracellular L. pneumophila from eradication by NaOCl, and play an essential role in resuscitation of VNC L. pneumophila in NaOCl-disinfected water sources. Intracellular L. pneumophila within trophozoites of A. polyphaga block encystation of the amoebae, and the resistance of both organisms to NaOCl is enhanced. To ensure long-term eradication and complete loss of the VNC state of L. pneumophila, we recommend that Legionella-protozoa co-culture should be an important tool to ensure complete loss of the VNC state of L. pneumophila.

  14. Effect of Legionella pneumophila sonicate on killing of Listeria monocytogenes by human polymorphonuclear neutrophils and monocytes

    DEFF Research Database (Denmark)

    Rechnitzer, C; Bangsborg, Jette Marie; Shand, G H

    1993-01-01

    Legionella pneumophila shares with other intracellular pathogens the ability to resist intracellular killing within phagocytes. An increasing number of cellular components of L. pneumophila are proposed as pathogenic factors of the organism. At the site of infection, the phagocytic cells will be ......Legionella pneumophila shares with other intracellular pathogens the ability to resist intracellular killing within phagocytes. An increasing number of cellular components of L. pneumophila are proposed as pathogenic factors of the organism. At the site of infection, the phagocytic cells...... are most likely to represent the inhibitory factors. The inhibitory activity of L. pneumophila sonic extract appears to be related to inhibition of killing mechanisms since uptake of Listeria was not affected by the sonicate. Our observations indicate that as Legionella infection progresses, bacterial...

  15. Simultaneous detection of Legionella species and Legionella pneumophila by duplex PCR (dPCR assay in cooling tower water samples from Jakarta, Indonesia

    Directory of Open Access Journals (Sweden)

    Andi Yasmon

    2010-11-01

    Full Text Available Aim: Since culture method is time-consuming and has low  sensitivity, we developed a duplex PCR (dPCR assay for the detection of Legionella sp. and L. pneumophila in cooling tower samples. We used culture method as a gold standard.Methods: Optimization of dPCR method was performed to obtain an assay with high sensitivity and specifi city. The optimized method was used to detect Legionella sp. dan L. pneumophila in 9 samples obtained from 9 buildings in Jakarta. For culture method, the bacteria were grown or isolated on selective growth factor supplemented-buffered charcoal yeast extract (BCYE media.Results: Of 9 samples tested by dPCR assay, 6 were positive for Legionella species,1 was positive for L. pneumophila, and 2 showed negative results. For the same samples, no Legionella sp. was detected by the culture method.Conclusion: dPCR assay was much more sensitive than the culture method and was potentially used as a rapid, specifi c and sensitive test for routine detection of Legionella sp. dan for L. pneumophila in water samples. (Med J Indones 2010; 19:223-7Keywords: BCYE media, mip gene, 16S-rRNA gene

  16. Characterization of an acetyltransferase that detoxifies aromatic chemicals in Legionella pneumophila

    DEFF Research Database (Denmark)

    Kubiak, Xavier Jean Philippe; Dervins-Ravault, Delphine; Pluvinage, Benjamin

    2012-01-01

    Legionella pneumophila is an opportunistic pathogen and the causative agent of Legionnaires' disease. Despite being exposed to many chemical compounds in its natural and man-made habitats (natural aquatic biotopes and man-made water systems), L. pneumophila is able to adapt and survive in these e...

  17. Hijacking of the Host Ubiquitin Network by Legionella pneumophila

    Directory of Open Access Journals (Sweden)

    Jiazhang Qiu

    2017-12-01

    Full Text Available Protein ubiquitination is critical for regulation of numerous eukaryotic cellular processes such as protein homeostasis, cell cycle progression, immune response, DNA repair, and vesicular trafficking. Ubiquitination often leads to the alteration of protein stability, subcellular localization, or interaction with other proteins. Given the importance of ubiquitination in the regulation of host immunity, it is not surprising that many infectious agents have evolved strategies to interfere with the ubiquitination network with sophisticated mechanisms such as functional mimicry. The facultative intracellular pathogen Legionella pneumophila is the causative agent of Legionnaires' disease. L. pneumophila is phagocytosed by macrophages and is able to replicate within a niche called Legionella-containing vacuole (LCV. The biogenesis of LCV is dependent upon the Dot/Icm type IV secretion system which delivers more than 330 effector proteins into host cytosol. The optimal intracellular replication of L. pneumophila requires the host ubiquitin-proteasome system. Furthermore, membranes of the bacterial phagosome are enriched with ubiquitinated proteins in a way that requires its Dot/Icm type IV secretion system, suggesting the involvement of effectors in the manipulation of the host ubiquitination machinery. Here we summarize recent advances in our understanding of mechanisms exploited by L. pneumophila effector proteins to hijack the host ubiquitination pathway.

  18. Effect of Legionella pneumophila cytotoxic protease on human neutrophil and monocyte function

    DEFF Research Database (Denmark)

    Rechnitzer, C; Kharazmi, A

    1992-01-01

    The extracellular metalloprotease of Legionella pneumophila, also called tissue-destructive protease or major secretory protein, has been proposed as one of the virulence factors of this organism. Considering the decisive role played by the phagocytic cells in host defense against Legionella...

  19. The membrane protein LasM Promotes the Culturability of Legionella pneumophila in Water

    Directory of Open Access Journals (Sweden)

    Laam Li

    2016-09-01

    Full Text Available The water-borne pathogen Legionella pneumophila (Lp strongly expresses the lpg1659 gene in water. This gene encodes a hypothetical protein predicted to be a membrane protein using in silico analysis. While no conserved domains were identified in Lpg1659, similar proteins are found in many Legionella species and other aquatic bacteria. RT-qPCR showed that lpg1659 is positively regulated by the alternative sigma factor RpoS, which is essential for Lp to survive in water. These observations suggest an important role of this novel protein in the survival of Lp in water. Deletion of lpg1659 did not affect cell morphology, membrane integrity or tolerance to high temperature. Moreover, lpg1659 was dispensable for growth of Lp in rich medium, and during infection of the amoeba Acanthamoeba castellanii and of THP-1 human macrophages. However, deletion of lpg1659 resulted in an early loss of culturability in water, while over-expression of this gene promoted the culturability of Lp. Therefore, these results suggest that lpg1659 is required for Lp to maintain culturability, and possibly long-term survival, in water. Since the loss of culturability observed in the absence of Lpg1659 was complemented by the addition of trace metals into water, this membrane protein is likely a transporter for acquiring essential trace metal for maintaining culturability in water and potentially in other metal-deprived conditions. Given its role in the survival of Lp in water, Lpg1659 was named LasM for Legionella aquatic survival membrane protein.

  20. A single Legionella pneumophila genotype in the freshwater system in a ship experiencing three separate outbreaks of legionellosis in 6 years

    Directory of Open Access Journals (Sweden)

    Catrine Ahlen

    2016-08-01

    Full Text Available Background: Recurrent legionella outbreaks at one and the same location are common. We have identified a single Legionella pneumophila genotype associated with recurrent Legionella outbreaks over 6 years. Methods: Field emergency surveys following Legionella outbreaks were performed on a vessel in 2008, 2009 and 2013. Water samples from both the distribution and technical parts of the potable water system were analyzed with respect to L. pneumophila [Real-Time PCR, cultivation, serotyping and genotyping (PFGE] and free-living amoebae, (FLA. Results: Legionella pneumophila serogroup 1 was present in the ship's potable water system during every outbreak. Genotyping of the 2008 survey material showed two separate PFGE genotypes while those in 2009 and 2013 demonstrated the presence of only one of the two genotypes. FLA with intracellular L. pneumophila of the same genotype were also detected. Analyses of the freshwater system on a ship following three separate Legionella outbreaks, for L. pneumophila and FLAs, revealed a single L. pneumophila genotype and FLA (Hartmanella. Conclusions: It is reasonable to assume that the L. pneumophila genotype detected in the freshwater system was the causal agent in the outbreaks onboard. Persistence of an apparently low-pathogenic L. pneumophila genotype and FLA in a potable water system represent a potential risk for recurrent outbreaks.

  1. Detection limits of Legionella pneumophila in environmental samples after co-culture with Acanthamoeba polyphaga

    Science.gov (United States)

    2013-01-01

    Background The efficiency of recovery and the detection limit of Legionella after co-culture with Acanthamoeba polyphaga are not known and so far no investigations have been carried out to determine the efficiency of the recovery of Legionella spp. by co-culture and compare it with that of conventional culturing methods. This study aimed to assess the detection limits of co-culture compared to culture for Legionella pneumophila in compost and air samples. Compost and air samples were spiked with known concentrations of L. pneumophila. Direct culturing and co-culture with amoebae were used in parallel to isolate L. pneumophila and recovery standard curves for both methods were produced for each sample. Results The co-culture proved to be more sensitive than the reference method, detecting 102-103 L. pneumophila cells in 1 g of spiked compost or 1 m3 of spiked air, as compared to 105-106 cells in 1 g of spiked compost and 1 m3 of spiked air. Conclusions Co-culture with amoebae is a useful, sensitive and reliable technique to enrich L. pneumophila in environmental samples that contain only low amounts of bacterial cells. PMID:23442526

  2. Isolation, identification, characterization and antibiotic sensitivity profile of pathogenic Legionella pneumophila isolates from different water sources

    Directory of Open Access Journals (Sweden)

    Kannan Subbaram

    2017-05-01

    Conclusions: Serious and fatal L. pneumophila infections may be transmitted through water. Legionella can survive under various conditions in various water sources. L. pneumophila is the important pathogen causing human disease. Great challenge prevails to health care professionals because these Legionellae acquired antibiotic resistance to many routinely prescribed antibiotics.

  3. Usefulness of real-time PCR as a complementary tool to the monitoring of Legionella spp. and Legionella pneumophila by culture in industrial cooling systems.

    Science.gov (United States)

    Touron-Bodilis, A; Pougnard, C; Frenkiel-Lebossé, H; Hallier-Soulier, S

    2011-08-01

    This study was designed to evaluate the usefulness of quantification by real-time PCR as a management tool to monitor concentrations of Legionella spp. and Legionella pneumophila in industrial cooling systems and its ability to anticipate culture trends by the French standard method (AFNOR T90-431). Quantifications of Legionella bacteria were achieved by both methods on samples from nine cooling systems with different water qualities. Proportion of positive samples for L. pneumophila quantified by PCR was clearly lower in deionized or river waters submitted to a biocide treatment than in raw river waters, while positive samples for Legionella spp. were quantified for almost all the samples. For some samples containing PCR inhibitors, high quantification limits (up to 4·80 × 10(5) GU l(-1) ) did not allow us to quantify L. pneumophila, when they were quantified by culture. Finally, the monitoring of concentrations of L. pneumophila by both methods showed similar trends for 57-100% of the samples. These results suggest that, if some methodological steps designed to reduce inhibitory problems and thus decrease the quantification limits, could be developed to quantify Legionella in complex waters, the real-time PCR could be a valuable complementary tool to monitor the evolution of L. pneumophila concentrations. This study shows the possibility of using real-time PCR to monitor L. pneumophila proliferations in cooling systems and the importance to adapt nucleic acid extraction and purification protocols to raw waters. Journal of Applied Microbiology © 2011 The Society for Applied Microbiology. No claim to French Government works.

  4. Application of ozonation process for the removal of Legionella pneumophila from water

    Directory of Open Access Journals (Sweden)

    Mohammad Safaee

    2015-09-01

    Full Text Available Background: Legionella pneumophila mortality and morbidity is a health concern worldwide. Due to the role of water in transmission of Legionenlla, several techniques have been used for water disinfection. This research was aimed to analyze the efficacy of ozonation process and the effects of bacterial density, contact time and pH on the removal of Legionella pneumophila from water. Methods: Legionella pneumophila was isolated from hospital water line and spiked into sterile drinking water with 300, 700 and 1000 CFU/ml densities. Ozonation was conducted within 1 L batch glass reactor with injection of 5 mg/h and contact time of 5 to 30 minutes at pH = 5, 7 and 9. Legionella culture was performed in supplemented BCYE containing GVPC and thermal treatment. After ozonation, the developed colonies were identified via biochemical and morphological tests. Results: In pH =5, the contact time 25 min and pH= 7 as well as the contact time 30 min, increase of legionella density from 300 to 1000 CFU/ml led to the reduction of removal efficiency from 100 to 87% and 100 to 82%, respectively. In pH=9 and contact time 20 min with the same bacterial density, 300 to 1000 CFU/ml, the disinfection efficacy was decreased from 100 to 91.5 %. Conclusion: Ozonation is an appropriate technique for elimination of legionella from water. The increased bacterial density led to the reduction of removal efficiency. The lowest and highest performance rates were obtained in pH=7 and 9, respectively.

  5. MTOR-Driven Metabolic Reprogramming Regulates Legionella pneumophila Intracellular Niche Homeostasis

    Science.gov (United States)

    Abshire, Camille F.; Roy, Craig R.

    2016-01-01

    Vacuolar bacterial pathogens are sheltered within unique membrane-bound organelles that expand over time to support bacterial replication. These compartments sequester bacterial molecules away from host cytosolic immunosurveillance pathways that induce antimicrobial responses. The mechanisms by which the human pulmonary pathogen Legionella pneumophila maintains niche homeostasis are poorly understood. We uncovered that the Legionella-containing vacuole (LCV) required a sustained supply of host lipids during expansion. Lipids shortage resulted in LCV rupture and initiation of a host cell death response, whereas excess of host lipids increased LCVs size and housing capacity. We found that lipids uptake from serum and de novo lipogenesis are distinct redundant supply mechanisms for membrane biogenesis in Legionella-infected macrophages. During infection, the metabolic checkpoint kinase Mechanistic Target of Rapamycin (MTOR) controlled lipogenesis through the Serum Response Element Binding Protein 1 and 2 (SREBP1/2) transcription factors. In Legionella-infected macrophages a host-driven response that required the Toll-like receptors (TLRs) adaptor protein Myeloid differentiation primary response gene 88 (Myd88) dampened MTOR signaling which in turn destabilized LCVs under serum starvation. Inactivation of the host MTOR-suppression pathway revealed that L. pneumophila sustained MTOR signaling throughout its intracellular infection cycle by a process that required the upstream regulator Phosphatidylinositol-4,5-bisphosphate 3-kinase (PI3K) and one or more Dot/Icm effector proteins. Legionella-sustained MTOR signaling facilitated LCV expansion and inhibition of the PI3K-MTOR-SREPB1/2 axis through pharmacological or genetic interference or by activation of the host MTOR-suppression response destabilized expanding LCVs, which in turn triggered cell death of infected macrophages. Our work identified a host metabolic requirement for LCV homeostasis and demonstrated that L

  6. AUTOMATED DEAD-END ULTRAFILTRATION FOR ENHANCED SURVEILLANCE OF LEGIONELLA 2 PNEUMOPHILA AND LEGIONELLA SPP. IN COOLING TOWER WATERS

    Energy Technology Data Exchange (ETDEWEB)

    Brigmon, R.; Leskinen, S.; Kearns, E.; Jones, W.; Miller, R.; Betivas, C.; Kingsley, M.; Lim, D.

    2011-10-10

    Detection of Legionella pneumophila in cooling towers and domestic hot water systems involves concentration by centrifugation or membrane filtration prior to inoculation onto growth media or analysis using techniques such as PCR or immunoassays. The Portable Multi-use Automated Concentration System (PMACS) was designed for concentrating microorganisms from large volumes of water in the field and was assessed for enhancing surveillance of L. pneumophila at the Savannah River Site, SC. PMACS samples (100 L; n = 28) were collected from six towers between August 2010 and April 2011 with grab samples (500 ml; n = 56) being collected before and after each PMACS sample. All samples were analyzed for the presence of L. pneumophila by direct fluorescence immunoassay (DFA) using FITC-labeled monoclonal antibodies targeting serogroups 1, 2, 4 and 6. QPCR was utilized for detection of Legionella spp. in the same samples. Counts of L. pneumophila from DFA and of Legionella spp. from qPCR were normalized to cells/L tower water. Concentrations were similar between grab and PMACS samples collected throughout the study by DFA analysis (P = 0.4461; repeated measures ANOVA). The same trend was observed with qPCR. However, PMACS concentration proved advantageous over membrane filtration by providing larger volume, more representative samples of the cooling tower environment, which led to reduced variability among sampling events and increasing the probability of detection of low level targets. These data highlight the utility of the PMACS for enhanced surveillance of L. pneumophila by providing improved sampling of the cooling tower environment.

  7. [Genomic DNA fingerprints of Legionella pneumophila serogroup 2 strains as an epidemiologic marker].

    Science.gov (United States)

    Bender-Beck, L; Mühlenberg, W; Lück, P C; Ott, M; Horbach, I; Fehrenbach, F J; Wewalka, G; Hacker, J

    1995-08-01

    Using pulsed-field gel electrophoresis, DNA fingerprints of eleven Legionella pneumophila isolates of serogroup 2 were generated. It was shown that two strains from a patient suffering from pneumonia as well as three environmental strains isolated from the shower in the hotel where the patient stayed 5 days before his illness were identical. Six strains of the same serogroup isolated from other sources were clearly separated. Thus, DNA fingerprints by pulsed-field gel electrophoresis are excellent epidemiological markers for the rarely occurring serogroup 2 of Legionella pneumophila.

  8. Satellite growth of Legionella pneumophila with an environmental isolate of Flavobacterium breve.

    Science.gov (United States)

    Wadowsky, R M; Yee, R B

    1983-12-01

    Legionella pneumophila serogroup 1 was observed to satellite around colonies of Flavobacterium breve on an L-cysteine-deficient medium which did not support growth of legionellae. Both isolates were recovered from the hot water tanks of hospitals. Ferric PPi stimulated satellite growth between 0.01 and 0.1%.

  9. Satellite growth of Legionella pneumophila with an environmental isolate of Flavobacterium breve.

    OpenAIRE

    Wadowsky, R M; Yee, R B

    1983-01-01

    Legionella pneumophila serogroup 1 was observed to satellite around colonies of Flavobacterium breve on an L-cysteine-deficient medium which did not support growth of legionellae. Both isolates were recovered from the hot water tanks of hospitals. Ferric PPi stimulated satellite growth between 0.01 and 0.1%.

  10. Genetic typing in a cluster of Legionella pneumophila infections

    NARCIS (Netherlands)

    van Ketel, R. J.; de Wever, B.

    1989-01-01

    Legionella pneumophila strains isolated from six patients, three air-conditioning- and cooling tower-derived strains, and three hot water supply-derived strains were analyzed by three genetic typing methods. The results of the whole-cell DNA restriction endonuclease analysis and the restriction

  11. Nucleotide sequence analysis of the Legionella micdadei mip gene, encoding a 30-kilodalton analog of the Legionella pneumophila Mip protein

    DEFF Research Database (Denmark)

    Bangsborg, Jette Marie; Cianciotto, N P; Hindersson, P

    1991-01-01

    After the demonstration of analogs of the Legionella pneumophila macrophage infectivity potentiator (Mip) protein in other Legionella species, the Legionella micdadei mip gene was cloned and expressed in Escherichia coli. DNA sequence analysis of the L. micdadei mip gene contained in the plasmid p...... homology with the mip-like genes of several Legionella species. Furthermore, amino acid sequence comparisons revealed significant homology to two eukaryotic proteins with isomerase activity (FK506-binding proteins)....

  12. In Vitro Activity of ABT-773 against Legionella pneumophila, Its Pharmacokinetics in Guinea Pigs, and Its Use to Treat Guinea Pigs with L. pneumophila Pneumonia

    OpenAIRE

    Edelstein, Paul H.; Higa, F.; Edelstein, Martha A. C.

    2001-01-01

    The activity of ABT-773 was studied against extracellular and intracellular Legionella pneumophila and for the treatment of guinea pigs with L. pneumophila pneumonia. The ABT-773 MIC at which 50% of isolates are inhibited (MIC50) for 20 different Legionella sp. strains was 0.016 μg/ml, whereas the MIC50s of clarithromycin and erythromycin were 0.032 and 0.125 μg/ml, respectively. ABT-773 (1 μg/ml) was bactericidal for two L. pneumophila strains grown in guinea pig alveolar macrophages. In con...

  13. Discovery of Ubiquitin Deamidases in the Pathogenic Arsenal of Legionella pneumophila

    Directory of Open Access Journals (Sweden)

    Dylan Valleau

    2018-04-01

    Full Text Available Summary: Legionella pneumophila translocates the largest known arsenal of over 330 pathogenic factors, called “effectors,” into host cells during infection, enabling L. pneumophila to establish a replicative niche inside diverse amebas and human macrophages. Here, we reveal that the L. pneumophila effectors MavC (Lpg2147 and MvcA (Lpg2148 are structural homologs of cycle inhibiting factor (Cif effectors and that the adjacent gene, lpg2149, produces a protein that directly inhibits their activity. In contrast to canonical Cifs, both MavC and MvcA contain an insertion domain and deamidate the residue Gln40 of ubiquitin but not Gln40 of NEDD8. MavC and MvcA are functionally diverse, with only MavC interacting with the human E2-conjugating enzyme UBE2N (Ubc13. MavC deamidates the UBE2N∼Ub conjugate, disrupting Lys63 ubiquitination and dampening NF-κB signaling. Combined, our data reveal a molecular mechanism of host manipulation by pathogenic bacteria and highlight the complex regulatory mechanisms integral to L. pneumophila’s pathogenic strategy. : Legionella pneumophila, possessing the largest known arsenal of effectors, continues to reveal unique approaches to host cell control. Valleau et al. decrypt the functions of a trio of effectors, discovering a pair of ubiquitin-specific deamidases, their regulation by a neighboring dual-specificity protein inhibitor, and a mechanism of NF-κB suppression. Keywords: pathogen-host interaction, ubiquitination, Legionella, UBE2N/Ubc13, NF-κB signaling, Type IV secretion system, effectors, metaeffector, cycle inhibiting factor

  14. The Amoebal MAP Kinase Response to Legionella pneumophila Is Regulated by DupA

    OpenAIRE

    Li, Zhiru; Dugan, Aisling S.; Bloomfield, Gareth; Skelton, Jason; Ivens, Alasdair; Losick, Vicki; Isberg, Ralph R.

    2009-01-01

    The amoeba Dictyostelium discoideum can support replication of Legionella pneumophila. Here we identify the dupA gene, encoding a putative tyrosine kinase/dual-specificity phosphatase, in a screen for D. discoideum mutants altered in allowing L. pneumophila intracellular replication. Inactivation of dupA resulted in depressed L. pneumophila growth and sustained hyperphosphorylation of the amoebal MAP kinase ERK1, consistent with loss of a phosphatase activity. Bacterial challenge of wild-type...

  15. Identification of vacuoles containing extraintestinal differentiated forms of Legionella pneumophila in colonized Caenorhabditis elegans soil nematodes.

    Science.gov (United States)

    Hellinga, Jacqueline R; Garduño, Rafael A; Kormish, Jay D; Tanner, Jennifer R; Khan, Deirdre; Buchko, Kristyn; Jimenez, Celine; Pinette, Mathieu M; Brassinga, Ann Karen C

    2015-08-01

    Legionella pneumophila, a causative agent of Legionnaires' disease, is a facultative intracellular parasite of freshwater protozoa. Legionella pneumophila features a unique developmental network that involves several developmental forms including the infectious cyst forms. Reservoirs of L. pneumophila include natural and man-made freshwater systems; however, recent studies have shown that isolates of L. pneumophila can also be obtained directly from garden potting soil suggesting the presence of an additional reservoir. A previous study employing the metazoan Caenorhabditis elegans, a member of the Rhabditidae family of free-living soil nematodes, demonstrated that the intestinal lumen can be colonized with L. pneumophila. While both replicative forms and differentiated forms were observed in C. elegans, these morphologically distinct forms were initially observed to be restricted to the intestinal lumen. Using live DIC imaging coupled with focused transmission electron microscopy analyses, we report here that L. pneumophila is able to invade and establish Legionella-containing vacuoles (LCVs) in the intestinal cells. In addition, LCVs containing replicative and differentiated cyst forms were observed in the pseudocoelomic cavity and gonadal tissue of nematodes colonized with L. pneumophila. Furthermore, establishment of LCVs in the gonadal tissue was Dot/Icm dependent and required the presence of the endocytic factor RME-1 to gain access to maturing oocytes. Our findings are novel as this is the first report, to our knowledge, of extraintestinal LCVs containing L. pneumophila cyst forms in C. elegans tissues, highlighting the potential of soil-dwelling nematodes as an alternate environmental reservoir for L. pneumophila. © 2015 The Authors. MicrobiologyOpen published by John Wiley & Sons Ltd.

  16. Free-living protozoa in drinking water supplies: community composition and role as hosts for Legionella pneumophila

    OpenAIRE

    Valster, R.M.

    2011-01-01

    Free-living protozoa in drinking water supplies: community composition and role as hosts for Legionella pneumophila Free-living protozoa, which feed on bacteria, play an important role in the communities of microorganisms and invertebrates in drinking water supplies and in (warm) tap water installations. Several bacteria, including opportunistic human pathogens such as Legionella pneumophila, are able to survive and replicate within protozoan hosts, and certain free-living protozoa are opp...

  17. An ELISA test for the detection of antibodies to Legionella pneumophila.

    OpenAIRE

    Wreghitt, T G; Nagington, J; Gray, J

    1982-01-01

    An enzyme-linked immunosorbent assay (ELISA) test has been developed to detect antibodies to Legionella pneumophila serogroup 1. There is good correlation between indirect fluorescent antibody (IFA) and ELISA titres but ELISA is more sensitive.

  18. Legionella pneumophila: risk assessment and strategy for the prevention and control of nosocomial infections

    Directory of Open Access Journals (Sweden)

    Salvo Torrisi

    2012-06-01

    Full Text Available The term “Legionellosis” includes all forms of disease caused by microorganisms of the genus Legionella; it may manifest as a flu-like shape (Pontiac fever, or with severe pneumonia with high mortality (Legionnaires Disease. The causative agent was Legionella pneumophila in the literature although other strains of the genus Legionella are classified as pathogens, mode of transmission is through inhalation of aerosol particles produced by hot water or air conditioning systems: for this reason in community settings and nosocomial L. pneumophila represents a serious public health problem. In the light of epidemiological data since the year 2000 the Italian State has issued a series of provisions laws concerning the prevention and control of nosocomial Legionellosis environment and community.The present work aims to evaluate the presence of Legionella species and L. pneumophila comparing the different approaches proposed by the Guidelines of the regions of Lombardy and Piedmont in terms of assessment and prevention of risk “Legionellosis” in the field of nosocomial infection. The analytical methods used are those provided by the Regional Guidelines: the official method in the second CSR April 4 Method 2000 and UNI EN ISO 11731-1: 2008. Checks have been performed on equipment for the comparison of cold water, hot water and air conditioning in nursing homes, retirement homes and hospitals.The results obtained show that the method CSR April 4, 2000 restricts the search to L. pneumophila permitting, than the method EN ISO 11731-1: 2008, to carry out a risk assessment well targeted to the actual pathogen.The culture method for the detection of L. pneumophila allows you to not only prevention, but also to implement a series of targeted interventions following the directions of the legislation.

  19. Rapid on-site monitoring of Legionella pneumophila in cooling tower water using a portable microfluidic system.

    Science.gov (United States)

    Yamaguchi, Nobuyasu; Tokunaga, Yusuke; Goto, Satoko; Fujii, Yudai; Banno, Fumiya; Edagawa, Akiko

    2017-06-08

    Legionnaires' disease, predominantly caused by the bacterium Legionella pneumophila, has increased in prevalence worldwide. The most common mode of transmission of Legionella is inhalation of contaminated aerosols, such as those generated by cooling towers. Simple, rapid and accurate methods to enumerate L. pneumophila are required to prevent the spread of this organism. Here, we applied a microfluidic device for on-chip fluorescent staining and semi-automated counting of L. pneumophila in cooling tower water. We also constructed a portable system for rapid on-site monitoring and used it to enumerate target bacterial cells rapidly flowing in the microchannel. A fluorescently-labelled polyclonal antibody was used for the selective detection of L. pneumophila serogroup 1 in the samples. The counts of L. pneumophila in cooling tower water obtained using the system and fluorescence microscopy were similar. The detection limit of the system was 10 4  cells/ml, but lower numbers of L. pneumophila cells (10 1 to 10 3  cells/ml) could be detected following concentration of 0.5-3 L of the water sample by filtration. Our technique is rapid to perform (1.5 h), semi-automated (on-chip staining and counting), and portable for on-site measurement, and it may therefore be effective in the initial screening of Legionella contamination in freshwater.

  20. Activity of Six Essential Oils Extracted from Tunisian Plants against Legionella pneumophila.

    Science.gov (United States)

    Chaftar, Naouel; Girardot, Marion; Quellard, Nathalie; Labanowski, Jérôme; Ghrairi, Tawfik; Hani, Khaled; Frère, Jacques; Imbert, Christine

    2015-10-01

    The aim of this study was to investigate the composition of six essential oils extracted from Tunisian plants, i.e., Artemisia herba-alba Asso, Citrus sinensis (L.) Osbeck, Juniperus phoenicea L., Rosmarinus officinalis L., Ruta graveolens L., and Thymus vulgaris L., and to evaluate their activity against Legionella pneumophila (microdilution assays). Eight Legionella pneumophila strains were studied, including the two well-known serogroup 1 Lens and Paris strains as controls and six environmental strains isolated from Tunisian spas belonging to serogroups 1, 4, 5, 6, and 8. The essential oils were generally active against L. pneumophila. The activities of the A. herba-alba, C. sinensis, and R. officinalis essential oils were strain-dependent, whereas those of the J. phoenicea and T. vulgaris oils, showing the highest anti-Legionella activities, with minimum inhibitory concentrations (MICs) lower than 0.03 and lower than or equal to 0.07 mg/ml, respectively, were independent of the strains' serogroup. Moreover, the microorganisms treated with T. vulgaris essential oil were shorter, swollen, and less electron-dense compared to the untreated controls. Isoborneol (20.91%), (1S)-α-pinene (18.30%) β-phellandrene (8.08%), α-campholenal (7.91%), and α-phellandrene (7.58%) were the major components isolated from the J. phoenicea oil, while carvacrol (88.50%) was the main compound of the T. vulgaris oil, followed by p-cymene (7.86%). This study highlighted the potential interest of some essential oils extracted from Tunisian plants as biocides to prevent the Legionella risk. Copyright © 2015 Verlag Helvetica Chimica Acta AG, Zürich.

  1. The Sensitization of Legionella pneumophila to Some Antibiotics by Reserpine and Anti-Legionella Effects of Different Benzofuranone Derivatives

    Directory of Open Access Journals (Sweden)

    Mohsen Khaleghi

    2015-10-01

    Full Text Available Background: Legionella pneumophila is  a  dangerous pathogenic bacterium can cause serious infectious diseases especially in hospitalized immuno-compromised patients. This bacterium is shown to be resistant against different antibiotics. Resistance against a wide range of antibiotics is usually mediated by efflux pump in bacteria. Efflux pumps are proteinaceous transporters localized in the cytoplasmic membrane of all kinds of cells which excreted antibiotics outside the cells. However, synthesis of new anti-Legionella compounds or selection of resistant modulating agents are useful strategy to combat with L. pneumophilain the future.Methods: In this study the antibacterial activity of some benzofuranone derivatives have been investigated by disk diffusion method against L. pneumophila. Also the sensitivity of this test strain was evaluated against 19 antibiotics and the combination effect of reserpine at a sub-inhibitory concentration was further studied with these antibiotics using disk diffusion method with some modifications.Conclusion: Among the different synthetic compounds which were tested against L. pneumophila, the most antibacterial activity was observed for compounds 1j and 1m which contain hydroxyl and methoxy groups on the C-6 and C-7 positionsagainst L. pneumophila. To evaluate whether efflux pumps are active in L. pneumophila or not an efflux inhibitor (reserpine was tested in combination of different antibiotics against this test strain. Reserpine significantly enhanced the antibacterial activities of kanamycin, nitrofurantoin, co-trimoxazole, erythromycin, ofloxacillin, gentamycin, rifampin, ciprofloxacin, nalidixic acid, minocycline, tobramycin, and amikacin against L. pneumophila which shows the resistances to these antibiotics are mediated by efflux system in this bacterium.

  2. A multicenter evaluation of genotypic methods for the epidemiologic typing of Legionella pneumophila serogroup 1

    DEFF Research Database (Denmark)

    Fry, Norman K.; Alexiou-Daniel, Stella; Bangsborg, Jette Marie

    1999-01-01

    OBJECTIVES: To compare genotypic methods for epidemiologic typing of Legionella pneumophila serogroup (sg) 1, in order to determine the best available method within Europe for implementation and standardization by members of the European Working Group on Legionella Infections. METHODS: Coded...

  3. Bakteri Legionella pneumophila Terdeteksi pada Air Kolam Renang di Kota Surabaya dengan Nested Polymerase Chain Reaction (LEGIONELLA PNEUMOPHILA BACTERIADETECTED IN SWIMMING POOL WATER OF SURABAYA BY USING NESTED POLYMERASE CHAIN REACTION

    Directory of Open Access Journals (Sweden)

    Eduardus Bimo Aksono

    2017-06-01

    Full Text Available Legionella pneumophila is a Gram-negative bacillus that causes nosocomial and community-acquired pneumonia. The aim of this research was to detect the presence of bacteria of L. pneumophila species in the swimming pools water of Surabaya city by using nested Polymerase Chain Reaction (PCR assay of a specific gene for L. pneumophila (mip gene. This study used purposive sampling method. A total of 10 water samples were collected from five swimming pools consisting of 200 mL water for each swimming pool. The results showed that of 10 samples tested by nested PCR, one sample was positive for L. pneumophila, and nine samples were negative. L. pneumophila were found in pool water samples with a higher temperature (>30ºC.Serogrouping analysis of positive sample that L. pneumophila bacteria detected in the water sample of swimming pool in Surabaya was L. pneumophila serogroup 9 (98% and serogroup 10 (98%. L. pneumophila detection of bacteria is expected to raise the awareness of physician and microbiologists about the transmission of L. pneumophila and will also be useful for controlling the agents. ABSTRAK Legionella pneumophila adalah bakteri Gram-negatif berbentuk batang yang dapat menyebabkan penyakit nosokomial dan pneumonia. Tujuan penelitian ini adalah untuk mendeteksi keberadaan bakteri L. pneumophila pada air kolam renang di Kota Surabaya dengan menggunakan nested Polymerase Chain Reaction (PCR berbasis gen spesifik L. pneumophila (mip gene. Penelitian ini menggunakan metode purposive sampling. Sebanyak sepuluh sampel diambil dari lima kolam renang. Sampel diambil sebanyak 200 mL dari air kolam renang di setiap lokasi. Hasil dari 10 sampel yang diuji menggunakan nested PCR, satu sampel menunjukkan hasil positif untuk L.pneumophila, dan sembilan sampel menunjukkan hasil negatif. Bakteri L. pneumophila ditemukan pada sampel air kolam dengan suhu yang lebih tinggi (>30ºC. Satu sampel positip tersebut ketika dilanjutkan terhadap analisis serogrup

  4. Severe Community-acquired Pneumonia Due to Legionella pneumophila Serogroup 6

    Directory of Open Access Journals (Sweden)

    Chung-Yu Chen

    2006-01-01

    Full Text Available Legionella pneumophila is a common cause of sporadic community-acquired pneumonia, but culture-proven legionellosis is rarely diagnosed. There is no laboratory test for Legionnaires' disease that can detect all patients with the disease. Culture is the standard diagnostic method and should be initiated as soon as possible in suspected cases. We describe a rare case of community-acquired pneumonia caused by L. pneumophila serogroup 6. A 77-year-old man was admitted to a tertiary care hospital because of high fever, productive cough, and progressive dyspnea. Chest radiography showed bilateral pneumonia, which led to respiratory failure necessitating mechanical ventilatory support. Despite antibiotic therapy, his condition continued to deteriorate and acute renal failure also developed. Urine was negative for L. pneumophila. Culture of the sputum yielded L. pneumophila serogroup 6, although there was no elevation of the serum antibody titer. Pneumonia resolved gradually and he was extubated after treatment with levofloxacin followed by erythromycin. L. pneumophila other than serogroup 1 should be included in the differential diagnosis of patients with suspected atypical community-acquired pneumonia.

  5. Neumonía por Legionella pneumophila: Experiencia en un Hospital Universitario de Buenos Aires Neumonia due to Legionella pneumophila. Experience gathered in a University Hospital in Buenos Aires

    Directory of Open Access Journals (Sweden)

    Carlos M. Luna

    2004-04-01

    Full Text Available La enfermedad de los legionarios es una causa de neumonía adquirida en la comunidad (NAC reconocida en todo el mundo. En Latinoamérica su incidencia es desconocida. En este estudio se analizó a 9 pacientes con NAC por Legionella pneumophila atendidos entre 1997 y 2001 en el Hospital de Clínicas José de San Martín de la Universidad de Buenos Aires. Se registraron datos de antecedentes, enfermedad actual, contactos, exposición laboral, examen físico, pruebas de laboratorio y uso previo de antibióticos, y se tomó en cuenta la presencia de criterios de gravedad. Nueve pacientes presentaron diagnóstico de NAC por Legionella, ninguno refirió antecedentes de viajes recientes; cuatro de ellos debieron ser internados en unidades de cuidado intensivo. Siete pacientes tenían antecedentes de tabaquismo, 4 tenían EPOC y un paciente linfoma no-Hodgkin. Nuestra casuística corrobora la baja especificidad de la clínica y estudios complementarios para predecir esta etiología. El aislamiento de Legionella es dificultoso, la seroconversión permite el diagnóstico retrospectivo y requiere plazos prolongados y el antígeno urinario aporta un diagnóstico inmediato. Cuando la legionelosis aparece en casos aislados, como ocurriría en Argentina, si no se piensa en esta etiología no se llegará al diagnóstico. Legionella pneumophila es un patógeno de NAC en nuestro medio, debe buscarse mejor, particularmente en pacientes graves, inmunodeprimidos y en fumadores con enfermedad pulmonar obstructiva crónica (EPOC.Legionnaires’ disease is a well recognized cause of community acquired pneumonia (CAP all around the world. In Latin America its incidence remains unknown. This study analyzed a cohort of 9 patients with CAP due to Legionella pneumophila observed from 1997 to 2001, in the Hospital de Clínicas José de San Martín, University of Buenos Aires. Clinical history included recent illnesses, work exposure, physical exam, prior antibiotic use and

  6. Travel-associated infections caused by unusual serogroups of Legionella pneumophila identified using Legionella BIOCHIP slides in Turkey and Iraq.

    Science.gov (United States)

    Kocazeybek, Bekir S; Yuksel, Pelin; Keskin, Dilek; Sheikh, Suhail; Habip, Zafer; Yavuzer, Serap Sahin; Caliskan, Reyhan; Altun, Yagız Meric; Kuskucu, Mert; Cengiz, Mahir; Dinc, Harika Oyku; Karakullukcu, Asiye; Ergin, Sevgi; Saribas, Suat; Yilmaz, Nail; Tokman, Hrisi Bahar

    2016-01-01

    Although Legionella pneumophila serogroup 1 is the common disease causing serogroup, rare serogroups can also may cause legionellosis. A 54-year-old male patient (index case) reported that he had been on a religious trip (for visiting, tomb of Ali, which is important for Shias) to Iraq with a large group (50 shia pilgrims from Kars city of Turkey) two weeks prior to admission. Due to civil war, the hotel where the patient stayed in Iraq lacked proper hygiene. A large number of people in the travel group were experiencing the same symptoms. Other five cases were 2 males (ages; 50, 45) and 3 females including the wife of the index case (ages; 50, 28, 27). The detection of L. pneumophila IgG and IgM was performed by anti-L. pneumophila Indirect Immunofluorescent IgM, IgG kit. Legionella 1 biochip/verification BIOCHIP slides were used for serogrouping in Euroimmun AG, Leubeck, Germany. In index case, L. pneumophila IgM was positive with a titer of 1/32 titer. IgG was negative with a 1/100 titer. Another case (28 year old female), had clinical symptoms identical to the index case. L. pneumophila IgM and IgG were positive with titers of 1/64 and 1/100, respectively. These two cases were diagnosed with Legionnaires' disease caused by L. pneumophila serogroup 12 (index case) and female (28-year-old) by serogroup 11. The other 4 cases were diagnosed with possible Pontiac fever caused by L. pneumophila serogroups 14 (wife of the index case), 4, and 6 whereas the serogroup of L. pneumophila detected in 27 years old female case could not be identified. A major limitation of this work is the absence of genotyping and the serogroup difference between index case and his wife who shared the same hotel. We suggest that this serogroup difference may be caused by (for men and women) sitting separately in Islamic rules. On the other hand, the movement of people in the context of mutual visits between countries or neighboring countries for tourism-related (i.e., for religious events

  7. The Legionella pneumophila kai operon is implicated in stress response and confers fitness in competitive environments

    Science.gov (United States)

    Loza-Correa, Maria; Sahr, Tobias; Rolando, Monica; Daniels, Craig; Petit, Pierre; Skarina, Tania; Valero, Laura Gomez; Dervins-Ravault, Delphine; Honoré, Nadine; Savchenko, Aleksey; Buchrieser, Carmen

    2014-01-01

    Summary Legionella pneumophila uses aquatic protozoa as replication niche and protection from harsh environments. Although L. pneumophila is not known to have a circadian clock, it encodes homologues of the KaiBC proteins of Cyanobacteria that regulate circadian gene expression. We show that L. pneumophila kaiB, kaiC and the downstream gene lpp1114, are transcribed as a unit under the control of the stress sigma factor RpoS. KaiC and KaiB of L. pneumophila do not interact as evidenced by yeast and bacterial two-hybrid analyses. Fusion of the C-terminal residues of cyanobacterial KaiB to Legionella KaiB restores their interaction. In contrast, KaiC of L. pneumophila conserved autophosphorylation activity, but KaiB does not trigger the dephosphorylation of KaiC like in Cyanobacteria. The crystal structure of L. pneumophila KaiB suggests that it is an oxidoreductase-like protein with a typical thioredoxin fold. Indeed, mutant analyses revealed that the kai operon-encoded proteins increase fitness of L. pneumophila in competitive environments, and confer higher resistance to oxidative and sodium stress. The phylogenetic analysis indicates that L. pneumophila KaiBC resemble Synechosystis KaiC2B2 and not circadian KaiB1C1. Thus, the L. pneumophila Kai proteins do not encode a circadian clock, but enhance stress resistance and adaption to changes in the environments. PMID:23957615

  8. A STUDY ON LEGIONELLA PNEUMOPHILA, WATER CHEMISTRY, AND ATMOSPHERIC CONDITIONS IN COOLING TOWERS AT THE SAVANNAH RIVER SITE

    Energy Technology Data Exchange (ETDEWEB)

    Smith, C.; Brigmon, R.

    2009-10-20

    Legionnaires disease is a pneumonia caused by the inhalation of the bacterium Legionella pneumophila. The majority of illnesses have been associated with cooling towers since these devices can harbor and disseminate the bacterium in the aerosolized mist generated by these systems. Historically, Savannah River Site (SRS) cooling towers have had occurrences of elevated levels of Legionella in all seasons of the year and in patterns that are difficult to predict. Since elevated Legionella in cooling tower water are a potential health concern a question has been raised as to the best control methodology. In this work we analyze available chemical, biological, and atmospheric data to determine the best method or key parameter for control. The SRS 4Q Industrial Hygiene Manual, 4Q-1203, 1 - G Cooling Tower Operation and the SRNL Legionella Sampling Program, states that 'Participation in the SRNL Legionella Sampling Program is MANDATORY for all operating cooling towers'. The resulting reports include L. pneumophila concentration information in cells/L. L. pneumophila concentrations >10{sup 7} cells/L are considered elevated and unsafe so action must be taken to reduce these densities. These remedial actions typically include increase biocide addition or 'shocking'. Sometimes additional actions are required if the problem persists including increase tower maintenance (e.g. cleaning). Evaluation of 14 SRS cooling towers, seven water quality parameters, and five Legionella serogroups over a three-plus year time frame demonstrated that cooling tower water Legionella densities varied widely though out this time period. In fact there was no one common consistent significant variable across all towers. The significant factors that did show up most frequently were related to suspended particulates, conductivity, pH, and dissolved oxygen, not chlorine or bromine as might be expected. Analyses of atmospheric data showed that there were more frequent significant

  9. Designation of the European Working Group on Legionella Infection (EWGLI) amplified fragment length polymorphism types of Legionella pneumophila serogroup 1 and results of intercentre proficiency testing Using a standard protocol

    DEFF Research Database (Denmark)

    Fry, N K; Bangsborg, Jette Marie; Bergmans, A

    2002-01-01

    The utility of amplified fragment length polymorphism (AFLP) analysis as a genotyping method for the epidemiological typing of Legionella pneumophila serogroup 1 has been previously demonstrated. This study (i). reports recommendations for the designation of the European Working Group on Legionella...... centres), and 92% (7 centres) to 100% (7 centres). The AFLP method as described is robust and rapid and allows the genotypic comparison of isolates of Legionella pneumophila between different testing centres without the need for exchange of the strains studied....

  10. Susceptibility of Legionella pneumophila to chlorine in tap water.

    Science.gov (United States)

    Kuchta, J M; States, S J; McNamara, A M; Wadowsky, R M; Yee, R B

    1983-11-01

    A study was conducted to compare the susceptibility of legionellae and coliforms to disinfection by chlorine. The chlorine residuals used were similar to concentrations that might be found in the distribution systems of large public potable water supplies. The effects of various chlorine concentrations, temperatures, and pH levels were considered. A number of different Legionella strains, both environmental and clinical, were tested. The results indicate that legionellae are much more resistant to chlorine than are coliform bacteria. At 21 degrees C, pH 7.6, and 0.1 mg of free chlorine residual per liter, a 99% kill of L. pneumophila was achieved within 40 min, compared with less than 1 min for Escherichia coli. The observed resistance is enhanced as conditions for disinfection become less optimal. The required contact time for the removal of L. pneumophilia was twice as long at 4 degrees C than it was at 21 degrees C. These data suggest that legionellae can survive low levels of chlorine for relatively long periods of time.

  11. Occurrence of Legionella pneumophila and Hartmannella vermiformis in fresh water environments and their interactions in biofilms

    NARCIS (Netherlands)

    Kuiper, M.W.

    2006-01-01

    Legionella pneumophila, the causative agent of Legionnaires’ disease, is widespread in natural fresh water environments and is also frequently found in man-made water systems. Microbial biofilms and protozoa are known to play a major role in the proliferation of L. pneumophila. Biofilms provide

  12. Effects of culture conditions and biofilm formation on the iodine susceptibility of Legionella pneumophila

    Science.gov (United States)

    Cargill, K. L.; Pyle, B. H.; Sauer, R. L.; McFeters, G. A.

    1992-01-01

    The susceptibility of Legionella pneumophila to iodination was studied with cultures grown in well water, on rich agar media, and attached to stainless-steel surfaces. Legionella pneumophila grown in water cultures in association with other microorganisms were less sensitive to disinfection by chlorine and iodine than were agar-passaged cultures. Differences in sensitivity to disinfection between water-cultured and agar-grown legionellae were determined by comparing C x T values (concentration in milligrams per litre multiplied by time in minutes to achieve 99% decrease in viability) and CM x T values (concentration in molarity). Iodine (1500x) gave a greater difference in CM x T values than did chlorine (68x). Iodine was 50 times more effective than chlorine when used with agar-grown cultures but was only twice as effective when tested against water-grown Legionella cultures. C x T x S values (C x T multiplied by percent survivors), which take into consideration the percent surviving bacteria, were used to compare sensitivities in very resistant populations, such as those in biofilms. Water cultures of legionellae associated with stainless-steel surfaces were 135 times more resistant to iodination than were unattached legionellae, and they were 210,000 times more resistant than were agar-grown cultures. These results indicate that the conditions under which legionellae are grown can dramatically affect their susceptibility to some disinfectants and must be considered when evaluating the efficacy of a disinfecting agent.

  13. Predictive parameters of Legionella pneumophila occurrence in hospital water: HPCs and plumbing system installation age.

    Science.gov (United States)

    Ghanizadeh, Ghader; Mirmohamadlou, Ali; Esmaeli, Davoud

    2016-09-01

    Occurrence of Legionella pneumophila can be relevant to the installation age and the presence of heterotrophic plate counts (HPCs). This research illustrates L. pneumophila contamination of hospital water in accordance with the installation age and the presence of HPCs. One hundred and fifty samples were collected from hot and cold water systems and cultured on R2A and BCYE agar. L. pneumophila identification was done via specific biochemical tests. HPCs and L. pneumophila were detected in 96 and 37.3 % of the samples, respectively. The mean of HPCs density was 947 ± 998 CFU/ml; therefore, 52 % of the samples had higher densities than 500 CFU/ml. High densities of HPCs (>500 CFU/ml) led to colonization of L. pneumophila (≥1000 CFU/ml), mainly observed in cooling systems, gynecological, sonography, and NICU wards. Chi(2) test demonstrated that higher densities (>500 CFU/ml) of HPCs and L. pneumophila contamination in cold water were more frequent than warm water (OR: 2.3 and 1.49, respectively). Univariate regressions implied a significant difference between HPCs density and installation age in positive and negative tests of L. pneumophila (OR = 1.1, p installation age on L. pneumophila occurrences (p installation age (r s  = 0.33, p installation age are relevant; so, plumbing system renovation with appropriate materials and promotion of the effective efforts for hospital's water quality assurance is highly recommended.

  14. Hot water systems as sources of Legionella pneumophila in hospital and nonhospital plumbing fixtures.

    Science.gov (United States)

    Wadowsky, R M; Yee, R B; Mezmar, L; Wing, E J; Dowling, J N

    1982-05-01

    Samples obtained from plumbing systems of hospitals, nonhospital institutions and homes were cultured for Legionella spp. by plating the samples directly on a selective medium. Swab samples were taken from the inner surfaces of faucet assemblies (aerators, spouts, and valve seats), showerheads, and shower pipes. Water and sediment were collected from the bottom of hot-water tanks. Legionella pneumophila serogroups 1, 5, and 6 were recovered from plumbing fixtures of the hospitals and nonhospital institutions and one of five homes. The legionellae (7 to 13,850 colony-forming units per ml) were also present in water and sediment from hot-water tanks maintained at 30 to 54 degrees C, but not in those maintained at 71 and 77 degrees C. Legionella micdadei was isolated from one tank. Thus legionellae are present in hot-water tanks which are maintained at warm temperatures or whose design results in warm temperatures at the bottom of the tanks. We hypothesize that hot-water tanks are a breeding site and a major source of L. pneumophila for the contamination of plumbing systems. The existence of these bacteria in the plumbing systems and tanks was not necessarily associated with disease. The extent of the hazard of this contamination needs to be delineated.

  15. Structural and functional studies of a Cu+-ATPase from Legionella pneumophila

    DEFF Research Database (Denmark)

    Mattle, Daniel

    During his studies, Daniel Mattle explored the copper(I) export mechanism of a P-type Cu+ ATPase from Legionella pneumophila – a homologue to the human Cu+ ATPases. Cu+ ATPases are responsible for the homeostatic control of the physiological relevant – but toxic – copper(I) cations. To assess...

  16. Molecular typing of Legionella pneumophila from air-conditioning cooling waters using mip gene, SBT, and FAFLP methods.

    Science.gov (United States)

    Gong, Xiangli; Li, Juntao; Zhang, Ying; Hou, Shuiping; Qu, Pinghua; Yang, Zhicong; Chen, Shouyi

    2017-08-01

    Legionella spp. are important waterborne pathogens. Molecular typing has become an important method for outbreaks investigations and source tracking of Legionnaires. In a survey program conducted by the Guangzhou Center for Disease Control and Prevention, multiple serotypes Legionella pneumophila (L. pneumophila) were isolated from waters in air-conditioning cooling towers in urban Guangzhou region, China between 2008 and 2011. Three genotyping methods, mip (macrophage infectivity potentiator) genotyping, SBT (sequence-based typing), and FAFLP (fluorescent amplified fragment length polymorphism analysis) were used to type these waterborne L. pneumophila isolates. The three methods were capable of typing all the 134 isolates and a reference strain of L. pneumophila (ATCC33153), with discriminatory indices of 0.7034, 0.9218, and 0.9376, for the mip, SBT, and FAFLP methods respectively. Among the 9 serotypes of the 134 isolates, 10, 50, and 34 molecular types were detected by the mip, SBT, and FAFLP methods respectively. The mip genotyping and SBT typing are more feasible for inter-laboratory results sharing and comparison of different types of L. pneumophila. The SBT and FAFLP typing methods were rapid with higher discriminatory abilities. Combinations of two or more of the typing methods enables more accurate typing of Legionella isolates for outbreak investigations and source tracking of Legionnaires. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Post-translational modifications are key players of the Legionella pneumophila infection strategy

    Science.gov (United States)

    Michard, Céline; Doublet, Patricia

    2015-01-01

    Post-translational modifications (PTMs) are widely used by eukaryotes to control the enzymatic activity, localization or stability of their proteins. Traditionally, it was believed that the broad biochemical diversity of the PTMs is restricted to eukaryotic cells, which exploit it in extensive networks to fine-tune various and complex cellular functions. During the last decade, the advanced detection methods of PTMs and functional studies of the host–pathogen relationships highlight that bacteria have also developed a large arsenal of PTMs, particularly to subvert host cell pathways to their benefit. Legionella pneumophila, the etiological agent of the severe pneumonia legionellosis, is the paradigm of highly adapted intravacuolar pathogens that have set up sophisticated biochemical strategies. Among them, L. pneumophila has evolved eukaryotic-like and rare/novel PTMs to hijack host cell processes. Here, we review recent progress about the diversity of PTMs catalyzed by Legionella: ubiquitination, prenylation, phosphorylation, glycosylation, methylation, AMPylation, and de-AMPylation, phosphocholination, and de-phosphocholination. We focus on the host cell pathways targeted by the bacteria catalyzed PTMs and we stress the importance of the PTMs in the Legionella infection strategy. Finally, we highlight that the discovery of these PTMs undoubtedly made significant breakthroughs on the molecular basis of Legionella pathogenesis but also lead the way in improving our knowledge of the eukaryotic PTMs and complex cellular processes that are associated to. PMID:25713573

  18. Characterization of a fluorescent compound isolated from Legionella pneumophila

    International Nuclear Information System (INIS)

    Swanson, S.J.

    1987-01-01

    Legionella pneumophila requires the presence of amino acids for growth and utilizes them for energy. Along with other amino acids, either phenylalanine or tyrosine is essential for the growth of the organism and tyrosine has been identified as an energy source. When L. pneumophila is grown in the presence of tyrosine, a brown melanin-like pigment is produced. A green fluorescent pigment, fg2, was isolated from centrifuged culture fluid after the organism was grown in the presence of tyrosine. Fg2 is water soluble with a molecular weight of 152 as determined by mass spectral analysis. A mutant of L. pneumophila unable to produce fg2 was isolated to assist in elucidation of the biosynthesis of fg2. Radiolabeling experiments were utilized to conclude that neither tyrosine nor any other amino acid was a precursor in the biosynthesis of fg2. Shikimic acid, an intermediate in tyrosine biosynthesis, was found to also be an intermediate in the biosynthesis of fg2. A series of experiments in which L. pneumophila was grown in a chemically defined medium containing various combinations of aromatic amino acids determined that fg2 and the brown pigment always occur in tandem

  19. Widespread molecular detection of Legionella pneumophila Serogroup 1 in cold water taps across the United States

    Science.gov (United States)

    In the United States 3,522 cases of legionellosis were reported to the Center for Disease Control and Prevention in 2009. Of these reports, it is estimated that 84% are caused by the microorganism Legionella pneumophila Serogroup (Sg) 1. Legionella spp. have been isolated and r...

  20. Research on Legionella pneumophila in hospital supply networks - DOI: 10.3395/reciis.v1i2.85en

    Directory of Open Access Journals (Sweden)

    Aldo Pacheco Ferreira

    2007-12-01

    Full Text Available The species of Legionella (gram-negative aerobic bacillus are widely distributed in water environments. The Legionellaceae family comprises a group of fastidious bacteria that requires special isolation techniques, and of which the Legionella pneumophila is the member which is most commonly identified as the cause of human diseases or of the worsening of health conditions. The purpose of this work is to verify conditions in randomly chosen hospitals from the public system for the development of Legionella pneumophila, and, thus, contribute to the debate on legislation and technical standardization in the network, with the purpose of controlling and preventing the presence of this bacillus in the Brazilian hospital system. At the same time, some physicochemical and colimetric parameters (total and thermo-tolerant coliforms were evaluated aiming at defining the total quality of water used. The results show the presence of coliforms and Legionella sp in the water used in the monitored hospitals. In this way, it is shown that the maintenance of the quality of water used in hospitals is fundamental, as well as the carrying out of biological tests for the detection of Legionella pneumophila so that the necessary safety of the hospital environment can be achieved.

  1. A comparison of assays measuring the viability of Legionella pneumophila after treatment with copper and silver ions

    Science.gov (United States)

    Background: The relatively high prevalence of Legionella pneumophila in premise plumbing systems has been widely reported. Published reports indicate Legionella has a comparatively high resistance to chlorine and moreover has the ability to grow in phagocytic amoeba which could p...

  2. Impact of drinking water conditions and copper materials on downstream biofilm microbial communities and legionella pneumophila colonization

    Science.gov (United States)

    Legionella pneumophila, the medically important species within the genus Legionella, is a concern in engineered water systems. Its ability to amplify within free-living amoebae is well documented, but its interactions/ecology within the microbial community of drinking water biofi...

  3. Computed tomographic features of 23 sporadic cases with Legionella pneumophila pneumonia

    International Nuclear Information System (INIS)

    Yu Hui; Higa, Futoshi; Hibiya, Kenji; Furugen, Makoto; Sato, Yoko; Shinzato, Takashi; Haranaga, Shusaku; Yara, Satomi; Tateyama, Masao; Fujita, Jiro; Li, Huiping

    2010-01-01

    Objective: To describe the chest computed tomographic (CT) findings of Legionella pneumophila pneumonia. Methods: CT scans obtained from 23 sporadic cases of L. pneumophila pneumonia were retrospectively reviewed. Chest CT findings were analyzed with regard to the patterns and distributions of pulmonary abnormalities. We also analyzed the histopathology of lungs from guinea pigs with experimentally induced L. pneumophila pneumonia. Results: Consolidation and ground-glass opacity (GGO) were the main findings of CT scans in L. pneumophila pneumonia. The distribution of opacities was categorized as non-segmental (n = 20) and segmental (n = 4). Non-segmental distribution may follow an onset of segmental distribution. Pleural effusion was observed in 14 (58.3%) patients, of which 13 were accompanied with non-segmental distribution. Abscess formation was observed in only one immunocompromised patient. In the animal pneumonia model, the lesions comprised of terminal bronchioles, alveolar spaces, and interstitia. Small bacilli were observed to be contained by many macrophages within the alveoli. Conclusion: Non-segmental distribution was significantly more frequent than segmental distribution in L. pneumophila pneumonia. It is possible that L. pneumophila infection initially results in segmental pneumonia, which progresses to typical non-segmental distribution.

  4. Computed tomographic features of 23 sporadic cases with Legionella pneumophila pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Yu Hui [Department of Respiratory Diseases, Shanghai Pneumology Hospital, Tongji University, Shanghai (China); Higa, Futoshi; Hibiya, Kenji; Furugen, Makoto [Department of Medicine and Therapeutics, Control and Prevention of Infectious Diseases (First Department of Internal Medicine), Faculty of Medicine, University of the Ryukyus, Okinawa (Japan); Sato, Yoko [Tomishiro Chuo Hospital, Okinawa (Japan); Shinzato, Takashi [Nakagami General Hospital, Okinawa (Japan); Haranaga, Shusaku; Yara, Satomi; Tateyama, Masao [Department of Medicine and Therapeutics, Control and Prevention of Infectious Diseases (First Department of Internal Medicine), Faculty of Medicine, University of the Ryukyus, Okinawa (Japan); Fujita, Jiro, E-mail: fujita@med.u-ryukyu.ac.j [Department of Medicine and Therapeutics, Control and Prevention of Infectious Diseases (First Department of Internal Medicine), Faculty of Medicine, University of the Ryukyus, Okinawa (Japan); Li, Huiping [Department of Respiratory Diseases, Shanghai Pneumology Hospital, Tongji University, Shanghai (China)

    2010-06-15

    Objective: To describe the chest computed tomographic (CT) findings of Legionella pneumophila pneumonia. Methods: CT scans obtained from 23 sporadic cases of L. pneumophila pneumonia were retrospectively reviewed. Chest CT findings were analyzed with regard to the patterns and distributions of pulmonary abnormalities. We also analyzed the histopathology of lungs from guinea pigs with experimentally induced L. pneumophila pneumonia. Results: Consolidation and ground-glass opacity (GGO) were the main findings of CT scans in L. pneumophila pneumonia. The distribution of opacities was categorized as non-segmental (n = 20) and segmental (n = 4). Non-segmental distribution may follow an onset of segmental distribution. Pleural effusion was observed in 14 (58.3%) patients, of which 13 were accompanied with non-segmental distribution. Abscess formation was observed in only one immunocompromised patient. In the animal pneumonia model, the lesions comprised of terminal bronchioles, alveolar spaces, and interstitia. Small bacilli were observed to be contained by many macrophages within the alveoli. Conclusion: Non-segmental distribution was significantly more frequent than segmental distribution in L. pneumophila pneumonia. It is possible that L. pneumophila infection initially results in segmental pneumonia, which progresses to typical non-segmental distribution.

  5. Detection of protozoan hosts for Legionella pneumophila in engineered water systems by using a biofilm batch test

    NARCIS (Netherlands)

    Valster, R.M.; Wullings, B.A.; Kooij, van der D.

    2010-01-01

    Legionella pneumophila proliferates in aquatic habitats within free-living protozoa, 17 species of which have been identified as hosts by using in vitro experiments. The present study aimed at identifying protozoan hosts for L. pneumophila by using a biofilm batch test (BBT). Samples (600 ml)

  6. Legionella pneumophila control in practice. Legionellenbekaempfung in der Praxis

    Energy Technology Data Exchange (ETDEWEB)

    Scharff, K

    1989-01-01

    Legionella pneumophila are wide-spread, rod-shaped bacilli (24 species with 40 serogroups are known to date) which preferably occur in water (lower growth limit is at 20deg C). Details are given on recommendations issued by the Federal Public Health Office. Thermal disinfection should be preferred to a chemical disinfection of drinking water. Recommendations such as water heating to 60deg C, regular cleaning of central clear-water reservoirs, self-draining shower hoses and shower heads, shut-off of unused pipe sections and connecting pipes should be put into practice applying easy-to-handle 60deg C tap water heating systems, circulating pipes, heated inlet pipes, decentralized flow heaters, storage system cleaning and pipe shut-off measures. Legionella research needs to be continued. (HWJ).

  7. Environmental surveillance of Legionella pneumophila in two Italian hospitals

    Directory of Open Access Journals (Sweden)

    Marina Tesauro

    2010-01-01

    Full Text Available The aim of this study was to identify the most effective disinfection protocol to reduce the presence of Legionella pneumophila in the water system of two Italian hospitals. From 2004 to 2009, 271 samplings of hot water were carried out in 11 hospital units to detect the presence of L. pneumophila. Additionally, water samples collected from one boiler outlet and the hot water recirculation were tested. From 2004 to 2009, L. pneumophila was present in 37% of the samples. Of these, 68.3% and 18.8% were positive for serogroups 2-14 and 1, respectively. Furthermore, 12.9% of the samples were positive for both serogroups. Finally, a maximal count of 10(4 CFU/L was measured in the most distal sites. To reduce L. pneumophila colonization, a two-year long hyperchlorination (2004-2006 was carried out. Moreover, from June 2005 until now, continuous maintenance of boilers and tanks, substitution of the shower heads and increase of the boiler outlet temperature to 60 ºC were performed. All these treatments led to a marked reduction of L. pneumophila colonization in the short but not in the medium-long term. Only the use of chlorine dioxide led, after four years, to a reduction of the loads of L. pneumophila to values below 100 CFU/L. However, in the distal sites a persistent degree of colonization (maximum value 700 CFU/L, average 600 CFU/L was observed probably due to the presence of L. pneumophila in the stagnant water in dead legs. In conclusion, data show that long-term chlorination of hot water sources together with carefully aimed maintenance of water pipes can lead to an effective reduction of L. pneumophila concentration in hospital water systems.

  8. Hyperoxia accelerates Fas-mediated signaling and apoptosis in the lungs of Legionella pneumophila pneumonia

    Directory of Open Access Journals (Sweden)

    Tanabe Yoshinari

    2011-04-01

    Full Text Available Abstract Background Oxygen supplementation is commonly given to the patients with severe pneumonia including Legionella disease. Recent data suggested that apoptosis may play an important role, not only in the pathogenesis of Legionella pneumonia, but also in oxygen-induced tissue damage. In the present study, the lethal sensitivity to Legionella pneumonia were compared in the setting of hyperoxia between wild-type and Fas-deficient mice. Findings C57BL/6 mice and B6.MRL-Faslpr mice characterized with Fas-deficiency were used in this study. After intratracheal administration of L. pneumophila, mice were kept in hyperoxic conditions (85-90% O2 conc. in an airtight chamber for 3 days. Bone-marrow derived macrophages infected with L. pneumophila were also kept in hyperoxic conditions. Caspase activity and cytokine production were determined by using commercially available kits. Smaller increases of several apoptosis markers, such as caspase-3 and -8, were demonstrated in Fas-deficient mice, even though the bacterial burdens in Fas-deficient and wild type mice were similar. Bone-marrow derived macrophages from Fas-deficient mice were shown to be more resistant to Legionella-induced cytotoxicity than those from wild-type mice under hyperoxia. Conclusions These results demonstrated that Fas-mediated signaling and apoptosis may be a crucial factor in the pathogenesis of Legionella pneumonia in the setting of hyperoxia.

  9. Detection of Legionella, L. pneumophila and Mycobacterium avium complex (MAC) along potable water distribution pipelines.

    Science.gov (United States)

    Whiley, Harriet; Keegan, Alexandra; Fallowfield, Howard; Bentham, Richard

    2014-07-18

    Inhalation of potable water presents a potential route of exposure to opportunistic pathogens and hence warrants significant public health concern. This study used qPCR to detect opportunistic pathogens Legionella spp., L. pneumophila and MAC at multiple points along two potable water distribution pipelines. One used chlorine disinfection and the other chloramine disinfection. Samples were collected four times over the year to provide seasonal variation and the chlorine or chloramine residual was measured during collection. Legionella spp., L. pneumophila and MAC were detected in both distribution systems throughout the year and were all detected at a maximum concentration of 103 copies/mL in the chlorine disinfected system and 106, 103 and 104 copies/mL respectively in the chloramine disinfected system. The concentrations of these opportunistic pathogens were primarily controlled throughout the distribution network through the maintenance of disinfection residuals. At a dead-end and when the disinfection residual was not maintained significant (p pipeline and sampling period. Total coliforms were not present in any water sample collected. This study demonstrates the ability of Legionella spp., L. pneumophila and MAC to survive the potable water disinfection process and highlights the need for greater measures to control these organisms along the distribution pipeline and at point of use.

  10. Legionella pneumophila: the paradox of a highly sensitive opportunistic waterborne pathogen able to persist in the environment

    Directory of Open Access Journals (Sweden)

    Jean-Marc eBerjeaud

    2016-04-01

    Full Text Available Legionella pneumophila, the major causative agent of Legionnaires’ disease, is found in freshwater environments in close association with free-living amoebae and multispecies biofilms, leading to persistence, spread, biocide resistance, and elevated virulence of the bacterium. Indeed, legionellosis outbreaks are mainly due to the ability of this bacterium to colonize and persist in water facilities, despite harsh physical and chemical treatments. However, these treatments are not totally efficient and, after a lag period, L. pneumophila may be able to quickly re-colonize these systems. Several natural compounds (biosurfactants, antimicrobial peptides… with anti-Legionella properties have recently been described in the literature, highlighting their specific activities against this pathogen. In this review, we first consider this hallmark of Legionella to resist killing, in regard to its biofilm or host-associated life style. Then, we focus more accurately on natural anti-Legionella molecules described so far, which could provide new eco-friendly and alternative ways to struggle against this important pathogen in plumbing.

  11. Occurrence of Opportunistic Pathogens Legionella pneumophila and non-tuberculous mycobacteria in hospital plumbing systems

    Science.gov (United States)

    Occurrence of Opportunistic Pathogens Legionella pneumophila and non-tuberculous mycobacteria in hospital plumbing systems Jill Hoelle, Michael Coughlin, Elizabeth Sotkiewicz, Jingrang Lu, Stacy Pfaller, Mark Rodgers, and Hodon Ryu U.S. Environmental Protection Agency, Cincinnati...

  12. Seasonal distribution of Legionella spp. and L. pneumophila in a river in Taiwan evaluated with culture-confirmed and direct DNA extraction methods

    Science.gov (United States)

    Tung, Min-Che; Chang, Tien-Yu; Hsu, Bing-Mu; Shen, Shu-Min; Huang, Jen-Te; Kao, Po-Min; Chiu, Yi-Chou; Fan, Cheng-Wei; Huang, Yu-Li

    2013-07-01

    In this study, we evaluated the presence and amount of Legionella in along a river in Taiwan, and the relations between seasonal distribution of Legionella spp. and geographic characteristics in the watershed were also evaluated. Water samples were pre-treated and analyzed with culture-confirmed and direct DNA extraction methods. For culture-confirmed method, water samples were cultivated through a series of selective media, and candidate colonies were confirmed by PCR. For direct DNA extraction method, direct DNA extraction was performed from pre-treated water samples. The DNA extracts were analyzed with PCR and DNA sequence analysis for species determination, quantitative PCR (qPCR) was performed to quantify Legionella concentration in the water sample. In all, 150 water samples were included in this study, with 73 (48.6%) water samples detected with Legionella spp., and 17 with L. pneumophila. Over 80% Legionella spp. detections were through direct DNA extraction method, but more than 80% L. pneumophila detections were through culture-confirmed method. While detection of Legionella spp. was done with two methods, positive results were found through only one method. Legionella spp. was detected in all seasons with detection rate ranging between 34.3-58.8% and seasonal average concentration from 1.9 × 102 to 7.1 × 103 CFU/L. Most of the L. pneumophila detections were from samples collected in fall (38.2%) and summer (6.0%), which also coincided with increased cases of Legionellosis reported through Center of Disease Control in Taiwan. The high prevalence and concentration of Legionella spp. and L. pneumophila in the surface waters should be further evaluated for potential health risks.

  13. Preferential colonization and release of Legionella pneumophila from mature drinking water biofilms grown on copper versus unplasticized polyvinylchloride coupons

    Science.gov (United States)

    Legionella persistence and amplification in premise drinking water systems is a known contributor to legionellosis outbreaks, especially in the presence of suitable eukaryotic hosts. Here we examined Legionella pneumophila behavior within drinking water biofilms grown on copper ...

  14. An investigation of virulence factors of Legionella pneumophila environmental isolates

    Directory of Open Access Journals (Sweden)

    Elif Özlem Arslan-Aydoğdu

    Full Text Available ABSTRACT Nine Legionella pneumophila strains isolated from cooling towers and a standard strain (L. pneumophila serogroup 1, ATCC 33152, Philadelphia 1 were analyzed and compared in terms of motility, flagella structure, ability to form biofilms, enzymatic activities (hemolysin, nucleases, protease, phospholipase A, phospholipase C, acid phosphatase, alkaline phosphatase and lipase, hemagglutination capabilities, and pathogenicity in various host cells (Acanthamoeba castellanii ATCC 30234, mouse peritoneal macrophages and human peripheral monocytes. All the isolates of bacteria appeared to be motile and polar-flagellated and possessed the type-IV fimbria. Upon the evaluation of virulence factors, isolate 4 was found to be the most pathogenic strain, while 6 out of the 9 isolates (the isolates 1, 2, 3, 4, 5, and 7 were more virulent than the ATCC 33152 strain. The different bacterial strains exhibited differences in properties such as adhesion, penetration and reproduction in the hosts, and preferred host type. To our knowledge, this is the first study to compare the virulence of environmental L. pneumophila strains isolated in Turkey, and it provides important information relevant for understanding the epidemiology of L. pneumophila.

  15. The amoebal MAP kinase response to Legionella pneumophila is regulated by DupA.

    Science.gov (United States)

    Li, Zhiru; Dugan, Aisling S; Bloomfield, Gareth; Skelton, Jason; Ivens, Alasdair; Losick, Vicki; Isberg, Ralph R

    2009-09-17

    The amoeba Dictyostelium discoideum can support replication of Legionella pneumophila. Here we identify the dupA gene, encoding a putative tyrosine kinase/dual-specificity phosphatase, in a screen for D. discoideum mutants altered in allowing L. pneumophila intracellular replication. Inactivation of dupA resulted in depressed L. pneumophila growth and sustained hyperphosphorylation of the amoebal MAP kinase ERK1, consistent with loss of a phosphatase activity. Bacterial challenge of wild-type amoebae induced dupA expression and resulted in transiently increased ERK1 phosphorylation, suggesting that dupA and ERK1 are part of a response to bacteria. Indeed, over 500 of the genes misregulated in the dupA(-) mutant were regulated in response to L. pneumophila infection, including some thought to have immune-like functions. MAP kinase phosphatases are known to be highly upregulated in macrophages challenged with L. pneumophila. Thus, DupA may regulate a MAP kinase response to bacteria that is conserved from amoebae to mammals.

  16. Effect of non-Legionellaceae bacteria on the multiplication of Legionella pneumophila in potable water.

    OpenAIRE

    Wadowsky, R M; Yee, R B

    1985-01-01

    A naturally occurring suspension of Legionella pneumophila and associated microbiota contained three unidentified non-Legionellaceae bacteria which supported satellite growth of a subculture of L. pneumophila on an L-cysteine-deficient medium and another bacterium which did not support growth of the subculture. Washed suspensions containing 10(3), 10(5), 10(7), or 10(8) CFU of a mixture of isolates of these non-Legionellaceae bacteria failed to support the multiplication of an isolate of agar...

  17. Invasion of Eukaryotic Cells by Legionella Pneumophila: A Common Strategy for all Hosts?

    Directory of Open Access Journals (Sweden)

    Paul S Hoffman

    1997-01-01

    Full Text Available Legionella pneumophila is an environmental micro-organism capable of producing an acute lobar pneumonia, commonly referred to as Legionnaires’ disease, in susceptible humans. Legionellae are ubiquitous in aquatic environments, where they survive in biofilms or intracellularly in various protozoans. Susceptible humans become infected by breathing aerosols laden with the bacteria. The target cell for human infection is the alveolar macrophage, in which the bacteria abrogate phagolysosomal fusion. The remarkable ability of L pneumophila to infect a wide range of eukaryotic cells suggests a common strategy that exploits very fundamental cellular processes. The bacteria enter host cells via coiling phagocytosis and quickly subvert organelle trafficking events, leading to formation of a replicative phagosome in which the bacteria multiply. Vegetative growth continues for 8 to 10 h, after which the bacteria develop into a short, highly motile form called the ‘mature form’. The mature form exhibits a thickening of the cell wall, stains red with the Gimenez stain, and is between 10 and 100 times more infectious than agar-grown bacteria. Following host cell lysis, the released bacteria infect other host cells, in which the mature form differentiates into a Gimenez-negative vegetative form, and the cycle begins anew. Virulence of L pneumophila is considered to be multifactorial, and there is growing evidence for both stage specific and sequential gene expression. Thus, L pneumophila may be a good model system for dissecting events associated with the host-parasite interactions.

  18. Detection of Legionella, L. pneumophila and Mycobacterium Avium Complex (MAC) along Potable Water Distribution Pipelines

    Science.gov (United States)

    Whiley, Harriet; Keegan, Alexandra; Fallowfield, Howard; Bentham, Richard

    2014-01-01

    Inhalation of potable water presents a potential route of exposure to opportunistic pathogens and hence warrants significant public health concern. This study used qPCR to detect opportunistic pathogens Legionella spp., L. pneumophila and MAC at multiple points along two potable water distribution pipelines. One used chlorine disinfection and the other chloramine disinfection. Samples were collected four times over the year to provide seasonal variation and the chlorine or chloramine residual was measured during collection. Legionella spp., L. pneumophila and MAC were detected in both distribution systems throughout the year and were all detected at a maximum concentration of 103 copies/mL in the chlorine disinfected system and 106, 103 and 104 copies/mL respectively in the chloramine disinfected system. The concentrations of these opportunistic pathogens were primarily controlled throughout the distribution network through the maintenance of disinfection residuals. At a dead-end and when the disinfection residual was not maintained significant (p < 0.05) increases in concentration were observed when compared to the concentration measured closest to the processing plant in the same pipeline and sampling period. Total coliforms were not present in any water sample collected. This study demonstrates the ability of Legionella spp., L. pneumophila and MAC to survive the potable water disinfection process and highlights the need for greater measures to control these organisms along the distribution pipeline and at point of use. PMID:25046636

  19. The transcriptome of Legionella pneumophila-infected human monocyte-derived macrophages.

    Directory of Open Access Journals (Sweden)

    Christopher T D Price

    Full Text Available Legionella pneumophila is an intracellular bacterial pathogen that invades and replicates within alveolar macrophages through injection of ∼ 300 effector proteins by its Dot/Icm type IV translocation apparatus. The bona fide F-box protein, AnkB, is a nutritional virulence effector that triggers macrophages to generate a surplus of amino acids, which is essential for intravacuolar proliferation. Therefore, the ankB mutant represents a novel genetic tool to determine the transcriptional response of human monocyte-derived macrophages (hMDMs to actively replicating L. pneumophila.Here, we utilized total human gene microarrays to determine the global transcriptional response of hMDMs to infection by wild type or the ankB mutant of L. pneumophila. The transcriptomes of hMDMs infected with either actively proliferating wild type or non-replicative ankB mutant bacteria were remarkably similar. The transcriptome of infected hMDMs was predominated by up-regulation of inflammatory pathways (IL-10 anti-inflammatory, interferon signaling and amphoterin signaling, anti-apoptosis, and down-regulation of protein synthesis pathways. In addition, L. pneumophila modulated diverse metabolic pathways, particularly those associated with bio-active lipid metabolism, and SLC amino acid transporters expression.Taken together, the hMDM transcriptional response to L. pneumophila is independent of intra-vacuolar replication of the bacteria and primarily involves modulation of the immune response and metabolic as well as nutritional pathways.

  20. Alkaline approach to treating cooling towers for control of Legionella pneumophila

    Energy Technology Data Exchange (ETDEWEB)

    States, S.J.; Conley, L.F.; Towner, S.G.; Wolford, R.S.; Stephenson, T.E.; McNamara, M.; Wadowsky, R.M.; Yee, R.B.

    1987-08-01

    Earlier field and laboratory studies have shown that Legionella species survive and multiply in the pH range 5.5 to 9.2. Additionally, the technical feasibility of operating cooling towers at elevated alkalinities and pH has previously been documented by published guidelines. The guidelines indicate that these conditions facilitate corrosion control and favor chlorine persistence which enhances the effectiveness of continuous chlorination in biofouling control. This information suggest that control of Legionella species in cooling towers can be accomplished by operating the towers under alkaline conditions. To test this possibility, we collected water samples over a period of months from a hospital cooling tower. The samples were analyzed for a variety of chemical parameters. Subsamples were pasteurized and inoculated with non-agar-passaged Legionella pneumophila which had been maintained in tap water. Correlation of subsequent Legionella growth with corresponding pH and alkalinity values revealed statistically significant inverse associations. These data support the hypothesis that operating cooling towers outside of the optimal conditions for Legionella growth (e.g., at elevated alkalinities and a pH greater than 9) may be a useful approach to controlling growth in this habitat.

  1. Activation of Ran GTPase by a Legionella effector promotes microtubule polymerization, pathogen vacuole motility and infection.

    Directory of Open Access Journals (Sweden)

    Eva Rothmeier

    2013-09-01

    Full Text Available The causative agent of Legionnaires' disease, Legionella pneumophila, uses the Icm/Dot type IV secretion system (T4SS to form in phagocytes a distinct "Legionella-containing vacuole" (LCV, which intercepts endosomal and secretory vesicle trafficking. Proteomics revealed the presence of the small GTPase Ran and its effector RanBP1 on purified LCVs. Here we validate that Ran and RanBP1 localize to LCVs and promote intracellular growth of L. pneumophila. Moreover, the L. pneumophila protein LegG1, which contains putative RCC1 Ran guanine nucleotide exchange factor (GEF domains, accumulates on LCVs in an Icm/Dot-dependent manner. L. pneumophila wild-type bacteria, but not strains lacking LegG1 or a functional Icm/Dot T4SS, activate Ran on LCVs, while purified LegG1 produces active Ran(GTP in cell lysates. L. pneumophila lacking legG1 is compromised for intracellular growth in macrophages and amoebae, yet is as cytotoxic as the wild-type strain. A downstream effect of LegG1 is to stabilize microtubules, as revealed by conventional and stimulated emission depletion (STED fluorescence microscopy, subcellular fractionation and Western blot, or by microbial microinjection through the T3SS of a Yersinia strain lacking endogenous effectors. Real-time fluorescence imaging indicates that LCVs harboring wild-type L. pneumophila rapidly move along microtubules, while LCVs harboring ΔlegG1 mutant bacteria are stalled. Together, our results demonstrate that Ran activation and RanBP1 promote LCV formation, and the Icm/Dot substrate LegG1 functions as a bacterial Ran activator, which localizes to LCVs and promotes microtubule stabilization, LCV motility as well as intracellular replication of L. pneumophila.

  2. Activation of Ran GTPase by a Legionella Effector Promotes Microtubule Polymerization, Pathogen Vacuole Motility and Infection

    Science.gov (United States)

    Rothmeier, Eva; Pfaffinger, Gudrun; Hoffmann, Christine; Harrison, Christopher F.; Grabmayr, Heinrich; Repnik, Urska; Hannemann, Mandy; Wölke, Stefan; Bausch, Andreas; Griffiths, Gareth; Müller-Taubenberger, Annette; Itzen, Aymelt; Hilbi, Hubert

    2013-01-01

    The causative agent of Legionnaires' disease, Legionella pneumophila, uses the Icm/Dot type IV secretion system (T4SS) to form in phagocytes a distinct “Legionella-containing vacuole” (LCV), which intercepts endosomal and secretory vesicle trafficking. Proteomics revealed the presence of the small GTPase Ran and its effector RanBP1 on purified LCVs. Here we validate that Ran and RanBP1 localize to LCVs and promote intracellular growth of L. pneumophila. Moreover, the L. pneumophila protein LegG1, which contains putative RCC1 Ran guanine nucleotide exchange factor (GEF) domains, accumulates on LCVs in an Icm/Dot-dependent manner. L. pneumophila wild-type bacteria, but not strains lacking LegG1 or a functional Icm/Dot T4SS, activate Ran on LCVs, while purified LegG1 produces active Ran(GTP) in cell lysates. L. pneumophila lacking legG1 is compromised for intracellular growth in macrophages and amoebae, yet is as cytotoxic as the wild-type strain. A downstream effect of LegG1 is to stabilize microtubules, as revealed by conventional and stimulated emission depletion (STED) fluorescence microscopy, subcellular fractionation and Western blot, or by microbial microinjection through the T3SS of a Yersinia strain lacking endogenous effectors. Real-time fluorescence imaging indicates that LCVs harboring wild-type L. pneumophila rapidly move along microtubules, while LCVs harboring ΔlegG1 mutant bacteria are stalled. Together, our results demonstrate that Ran activation and RanBP1 promote LCV formation, and the Icm/Dot substrate LegG1 functions as a bacterial Ran activator, which localizes to LCVs and promotes microtubule stabilization, LCV motility as well as intracellular replication of L. pneumophila. PMID:24068924

  3. Characterization of a Legionella micdadei mip mutant

    DEFF Research Database (Denmark)

    O'Connell, W A; Bangsborg, Jette Marie; Cianciotto, N P

    1995-01-01

    The pathogenesis of Legionella micdadei is dependent upon its ability to infect alveolar phagocytes. To better understand the basis of intracellular infection by this organism, we examined the importance of its Mip surface protein. In Legionella pneumophila, Mip promotes infection of both human...

  4. Epidemiology and Ecology of Opportunistic Premise Plumbing Pathogens: Legionella pneumophila, Mycobacterium avium, and Pseudomonas aeruginosa

    Science.gov (United States)

    BACKGROUND: Legionella pneumophila, Mycobacterium avium, and Pseudomonas aeruginosa are opportunistic premise plumbing pathogens (OPPPs) that persist and grow in household plumbing, habitats they share with humans. Infections caused by these OPPPs involve individuals with preexis...

  5. Effects of metals on Legionella pneumophila growth in drinking water plumbing systems.

    Science.gov (United States)

    States, S J; Conley, L F; Ceraso, M; Stephenson, T E; Wolford, R S; Wadowsky, R M; McNamara, A M; Yee, R B

    1985-11-01

    An investigation of the chemical environment and growth of Legionella pneumophila in plumbing systems was conducted to gain a better understanding of its ecology in this habitat. Water samples were collected from hospital and institutional hot-water tanks known to have supported L. pneumophila and were analyzed for 23 chemical parameters. The chemical environment of these tanks was found to vary extensively, with the concentrations of certain metals reaching relatively high levels due to corrosion. The effect of various chemical conditions on L. pneumophila growth was then examined by observing its multiplication in the chemically analyzed hot-water tank samples after sterilization and reinoculation with L. pneumophila. L. pneumophila and associated microbiota used in these experiments were obtained from a hot-water tank. These stains were maintained in tap water and had never been passaged on agar. The results of the growth studies indicate that although elevated concentrations of a number of metals are toxic, lower levels of certain metals such as iron, zinc, and potassium enhance growth of naturally occurring L. pneumophila. Parallel observations on accompanying non-Legionellaceae bacteria failed to show the same relationship. These findings suggest that metal plumbing components and associated corrosion products are important factors in the survival and growth of L. pneumophila in plumbing systems and may also be important in related habitats such as cooling towers and air-conditioning systems.

  6. Planktonic replication is essential for biofilm formation by Legionella pneumophila in a complex medium under static and dynamic flow conditions

    DEFF Research Database (Denmark)

    Mampel, J.; Spirig, T.; Weber, S.S.

    2006-01-01

    Legionella pneumophila persists for a long time in aquatic habitats, where the bacteria associate with biofilms and replicate within protozoan predators. While L. pneumophila serves as a paradigm for intracellular growth within protozoa, it is less clear whether the bacteria form or replicate...

  7. Characterization of a major 31-kilodalton peptidoglycan-bound protein of Legionella pneumophila

    International Nuclear Information System (INIS)

    Butler, C.A.; Hoffman, P.S.

    1990-01-01

    A 31-kilodalton (kDa) protein was solubilized from the peptidoglycan (PG) fraction of Legionella pneumophila after treatment with either N-acetylmuramidase from the fungus Chalaropsis sp. or with mutanolysin from Streptomyces globisporus. The protein exhibited a ladderlike banding pattern by autoradiography when radiolabeled [(35S]cysteine or [35S]methionine) PG material was extensively treated with hen lysozyme. The banding patterns ranging between 31 and 45 kDa and between 55 and 60 kDa resolved as a single 31-kDa protein when the material was subsequently treated with N-acetylmuramidase. Analysis of the purified 31-kDa protein for diaminopimelic acid by gas chromatography revealed 1 mol of diaminopimelic acid per mol of protein. When outer membrane PG material containing the major outer membrane porin protein was treated with N-acetylmuramidase or mutanolysin, both the 28.5-kDa major outer membrane protein and the 31-kDa protein were solubilized from the PG material under reducing conditions. In the absence of 2-mercaptoethanol, a high-molecular-mass complex (100 kDa) was resolved. The results of this study indicate that a 31-kDa PG-bound protein is a major component of the cell wall of L. pneumophila whose function may be to anchor the major outer membrane protein to PG. Finally, a survey of other Legionella species and other serogroups of L. pneumophila suggested that PG-bound proteins may be a common feature of this genus

  8. [Community-acquired pneumonia due to Legionella pneumophila serogroup 1. Study of 97 cases].

    Science.gov (United States)

    Benito, José Ramón; Montejo, José Miguel; Cancelo, Laura; Zalacaín, Rafael; López, Leyre; Fernández Gil de Pareja, Joaquín; Alonso, Eva; Oñate, Javier

    2003-10-01

    Legionella pneumophila is the causal agent of 5% to 12% of sporadic community-acquired pneumonia cases, though rates are changing with the use of new diagnostic methods. This is a retrospective study of all patients admitted to our hospital with community-acquired pneumonia due to Legionella pneumophila between 1997 and 2001. Diagnostic criteria included either a positive Legionella serogroup 1 urinary antigen test or seroconversion and a chest radiograph consistent with pneumonia. A total of 97 patients were studied. Ninety cases (92.8%) were community-acquired and 7 (7.2%) were associated with travelling. In 82 cases (84.5%) the presentation was sporadic. Seventy-five patients were smokers (77.3%). The most common symptoms were fever in 91 patients (93.8%) and cough in 67 (68.1%). In five patients (5.2%) creatine phosphokinase concentrations were over 5 times their baseline values (in two over 100 times); four of these patients presented acute renal failure. Seroconversion was observed in 23/42 patients (54.8%). There were no statistically significant differences between the administration of erythromycin or clarithromycin in monotherapy, or in combination with rifampin. Nineteen patients (19.6%) presented acute renal failure and mechanical ventilation was necessary in 22 (22.7%). Twelve patients died (12.5%). Independent prognostic factors associated with death included respiratory rate > 30 breaths/min, urea > 60 mg/dL and PaO2 scale scores and the presence of complications or mortality. The Legionella urinary antigen test permits early diagnosis and treatment of this disease. The severity scale is an indicator of complications or death.

  9. Origin and prevention of infection with Legionella pneumophila through cooling towers and evaporative cooling towers

    International Nuclear Information System (INIS)

    Schulze-Roebbecke, R.

    1994-01-01

    Evaporative cooling towers and industrial ventilator cooling towers have repeatedly been described as the origin of Legionnaires' disease. This article describes the design and function of cooling towers and evaporative cooling towers, sums up knowledge on the colonization of such systems with Legionella pneumophila, and describes conditions permitting the transmission of Legionella. Furthermore, design, maintenance, cleaning and disinfection measures are indicated which are believed to reduce the risk of infection through industrial and evaporative cooling towers. (orig.) [de

  10. Dendrimers and polyamino-phenolic ligands: activity of new molecules against Legionella pneumophila biofilms.

    Directory of Open Access Journals (Sweden)

    Elisa eAndreozzi

    2016-03-01

    Full Text Available Legionnaires’ disease is a potentially fatal pneumonia caused by Legionella pneumophila, an aquatic bacterium often found within the biofilm niche. In man-made water systems microbial biofilms increase the resistance of legionella to disinfection, posing a significant threat to public health. Disinfection methods currently used in water systems have been shown to be ineffective against legionella over the long-term, allowing recolonization by the biofilm-protected microorganisms. In this study, the anti-biofilm activity of previously fabricated polyamino-phenolic ligands and polyamidoamine dendrimers was investigated against legionella mono-species and multi-species biofilms formed by L. pneumophila in association with other bacteria that can be found in tap water (Aeromonas hydrophila, Pseudomonas aeruginosa, Escherichia coli, Klebsiella pneumoniae. Bacterial ability to form biofilms was verified using a crystal violet colorimetric assay and testing cell viability by real-time quantitative PCR and Plate Count assay. The concentration of the chemicals tested as anti-biofilm agents was chosen based on cytotoxicity assays: the highest non-cytotoxic chemical concentration was used for biofilm inhibition assays, with dendrimer concentration ten-fold higher than polyamino-phenolic ligands. While Macrophen and Double Macrophen were the most active substances among polyamino-phenolic ligands, dendrimers were overall two-fold more effective than all other compounds with a reduction up to 85% and 73% of legionella and multi-species biofilms, respectively. Chemical interaction with matrix molecules is hypothesized, based on SEM images and considering the low or absent anti-microbial activity on planktonic bacteria showed by flow cytometry. These data suggest that the studied compounds, especially dendrimers, could be considered as novel molecules in the design of research projects aimed at the development of efficacious anti-biofilm disinfection

  11. Topology of Legionella pneumophila DotA: an inner membrane protein required for replication in macrophages.

    OpenAIRE

    Roy, C R; Isberg, R R

    1997-01-01

    The Legionella pneumophila dotA gene is required for intracellular growth of the bacterium in macrophages. In this study, a structure-function analysis of the DotA protein was conducted to elucidate the role of this protein in L. pneumophila pathogenesis. Translational fusions of dotA to the Escherichia coli phoA and lacZ genes indicated that DotA is an integral cytoplasmic membrane protein with eight membrane-spanning domains. DotA contains two large periplasmic domains of approximately 503 ...

  12. An alkaline approach to treating cooling towers for control of Legionella pneumophila.

    Science.gov (United States)

    States, S J; Conley, L F; Towner, S G; Wolford, R S; Stephenson, T E; McNamara, A M; Wadowsky, R M; Yee, R B

    1987-08-01

    Earlier field and laboratory studies have shown that Legionella species survive and multiply in the pH range 5.5 to 9.2. Additionally, the technical feasibility of operating cooling towers at elevated alkalinities and pH has previously been documented by published guidelines. The guidelines indicate that these conditions facilitate corrosion control and favor chlorine persistence which enhances the effectiveness of continuous chlorination in biofouling control. This information suggests that control of Legionella species in cooling towers can be accomplished by operating the towers under alkaline conditions. To test this possibility, we collected water samples over a period of months from a hospital cooling tower. The samples were analyzed for a variety of chemical parameters. Subsamples were pasteurized and inoculated with non-agar-passaged Legionella pneumophila which had been maintained in tap water. Correlation of subsequent Legionella growth with corresponding pH and alkalinity values revealed statistically significant inverse associations. These data support the hypothesis that operating cooling towers outside of the optimal conditions for Legionella growth (e.g., at elevated alkalinities and a pH greater than 9) may be a useful approach to controlling growth in this habitat.

  13. Incubation of premise plumbing water samples on Buffered Charcoal Yeast Extract agar at elevated temperature and pH selects for Legionella pneumophila.

    Science.gov (United States)

    Veenendaal, Harm R; Brouwer-Hanzens, Anke J; van der Kooij, Dick

    2017-10-15

    Worldwide, over 90% of the notified cases of Legionnaires' disease are caused by Legionella pneumophila. However, the standard culture medium for the detection of Legionella in environmental water samples, Buffered Charcoal Yeast Extract (BCYE) agar of pH 6.9 ± 0.4 with or without antimicrobial agents incubated at 36 ± 1 °C, supports the growth of a large diversity of Legionella species. BCYE agar of elevated pH or/and incubation at elevated temperature gave strongly reduced recoveries of most of 26 L. non-pneumophila spp. tested, but not of L. pneumophila. BCYE agar of pH 7.3 ± 0.1, incubated at 40 ± 0.5 °C (BCYE pH 7.3/40 °C) was tested for selective enumeration of L. pneumophila. Of the L. non-pneumophila spp. tested, only L. adelaidensis and L. londiniensis multiplied under these conditions. The colony counts on BCYE pH 7.3/40 °C of a L. pneumophila serogroup 1 strain cultured in tap water did not differ significantly from those on BCYE pH 6.9/36 °C when directly plated and after membrane filtration and showed repeatability's of 13-14%. By using membrane filtration L. pneumophila was detected in 58 (54%) of 107 Legionella-positive water samples from premise plumbing systems under one or both of these culture conditions. The L. pneumophila colony counts (log-transformed) on BCYE pH 7.3/40 °C were strongly related (r 2  = 0.87) to those on BCYE pH 6.9/36 °C, but differed significantly (p < 0.05) by a mean of - 0.12 ± 0.30 logs. L. non-pneumophila spp. were detected only on BCYE pH 6.9/36 °C in 49 (46%) of the samples. Hence, BCYE pH 7.3/40 °C can facilitate the enumeration of L. pneumophila and their isolation from premise plumbing systems with culturable L. non-pneumophila spp., some of which, e.g. L. anisa, can be present in high numbers. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. A Multiplex PCR for Detection of Mycoplasma pneumoniae, Chlamydophila pneumoniae, Legionella pneumophila, and Bordetella pertussis in Clinical Specimens

    National Research Council Canada - National Science Library

    McDonough, E. A; Barrozo, C. P; Russell, K. L; Metzgar, D

    2005-01-01

    A multiplex PCR was developed that is capable of detecting four of the most important bacterial agents of atypical pneumophia, Mycaplasma pneumoniae, Chlamydophia pneumoniae, Legionella pneumophila...

  15. Assessment of intercentre reproducibility and epidemiological concordance of Legionella pneumophila serogroup 1 genotyping by amplified fragment length polymorphism analysis

    DEFF Research Database (Denmark)

    Fry, N K; Bangsborg, Jette Marie; Bernander, S

    2000-01-01

    The aims of this work were to assess (i) the intercentre reproducibility and epidemiological concordance of amplified fragment length polymorphism analysis for epidemiological typing of Legionella pneumophila serogroup 1, and (ii) the suitability of the method for standardisation and implementation...... by members of the European Working Group on Legionella Infections. Fifty coded isolates comprising two panels of well-characterised strains, a "reproducibility" panel (n=20) and an "epidemiologically related" panel (n=30), were sent to 13 centres in 12 European countries. Analysis was undertaken in each...... using gel analysis software yielded R=1.00 and E=1.00, with 12, 13 or 14 types. This method can be used as a simple, rapid screening tool for epidemiological typing of isolates of Legionella pneumophila serogroup 1. Results demonstrate that the method can be highly reproducible (R=1...

  16. Chlamydia trachomatis contains a protein similar to the Legionella pneumophila mip gene product

    DEFF Research Database (Denmark)

    Lundemose, AG; Birkelund, Svend; Fey, SJ

    1991-01-01

    A 27kDa Chlamydia trachomatis L2 protein was characterized by the use of monoclonal antibodies and by two-dimensional gel electrophoresis. The protein was shown to be located in the membrane of reticulate bodies as well as elementary bodies. Its synthesis could be detected from 10 hours post-infe...... potentiator (mip) gene of Legionella pneumophila....

  17. Survival and multiplication of Legionella pneumophila in municipal drinking water systems.

    Science.gov (United States)

    States, S J; Conley, L F; Kuchta, J M; Oleck, B M; Lipovich, M J; Wolford, R S; Wadowsky, R M; McNamara, A M; Sykora, J L; Keleti, G

    1987-05-01

    Studies were conducted to investigate the survival and multiplication of Legionella spp. in public drinking water supplies. An attempt was made, over a period of several years, to isolate legionellae from a municipal system. Sampling sites included the river water supply, treatment plant, finished water reservoir system, mains, and distribution taps. Despite the use of several isolation techniques, Legionella spp. could not be detected in any of the samples other than those collected from the river. It was hypothesized that this was due to the maintenance of a chlorine residual throughout the system. To investigate the potential for Legionella growth, additional water samples, collected from throughout the system, were dechlorinated, pasteurized, and inoculated with Legionella pneumophila. Subsequent growth indicated that many of these samples, especially those collected from areas affected by an accumulation of algal materials, exhibited a much greater ability to support Legionella multiplication than did river water prior to treatment. Chemical analyses were also performed on these samples. Correlation of chemical data and experimental growth results indicated that the chemical environment significantly affects the ability of the water to support multiplication, with turbidity, organic carbon, and certain metals being of particular importance. These studies indicate that the potential exists for Legionella growth within municipal systems and support the hypothesis that public water supplies may contaminate the plumbing systems of hospitals and other large buildings. The results also suggest that useful methods to control this contamination include adequate treatment plant filtration, maintenance of a chlorine residual throughout the treatment and distribution network, and effective covering of open reservoirs.

  18. Prevalence of Infection-Competent Serogroup 6 Legionella pneumophila within Premise Plumbing in Southeast Michigan

    Directory of Open Access Journals (Sweden)

    Brenda G. Byrne

    2018-02-01

    Full Text Available Coinciding with major changes to its municipal water system, Flint, MI, endured Legionnaires’ disease outbreaks in 2014 and 2015. By sampling premise plumbing in Flint in the fall of 2016, we found that 12% of homes harbored legionellae, a frequency similar to that in residences in neighboring areas. To evaluate the genetic diversity of Legionella pneumophila in Southeast Michigan, we determined the sequence type (ST and serogroup (SG of the 18 residential isolates from Flint and Detroit, MI, and the 33 clinical isolates submitted by hospitals in three area counties in 2013 to 2016. Common to one environmental and four clinical samples were strains of L. pneumophila SG1 and ST1, the most prevalent ST worldwide. Among the Flint premise plumbing isolates, 14 of 16 strains were of ST367 and ST461, two closely related SG6 strain types isolated previously from patients and corresponding environmental samples. Each of the representative SG1 clinical strains and SG6 environmental isolates from Southeast Michigan infected and survived within macrophage cultures at least as well as a virulent laboratory strain, as judged by microscopy and by enumerating CFU. Likewise, 72 h after infection, the yield of viable-cell counts increased >100-fold for each of the representative SG1 clinical isolates, Flint premise plumbing SG6 ST367 and -461 isolates, and two Detroit residential isolates. We verified by immunostaining that SG1-specific antibody does not cross-react with the SG6 L. pneumophila environmental strains. Because the widely used urinary antigen diagnostic test does not readily detect non-SG1 L. pneumophila, Legionnaires’ disease caused by SG6 L. pneumophila is likely underreported worldwide.

  19. Zakażenia pałeczkami Legionella pneumophila – opis przypadku

    Directory of Open Access Journals (Sweden)

    Bolesław Kalicki

    2011-12-01

    Full Text Available Legionella pneumophila jest wewnątrzkomórkowym patogenem zasiedlającym środowiska wodne. Do zakażenia dochodzi drogą inhalacji zakażonego aerozolu, rzadziej poprzez aspirację. Rozprzestrzenianie się zachodzi drogą krwionośną, limfatyczną i przez ciągłość. Choroba rozwija się w postaci dwóch klinicznie odrębnych zespołów: choroby legionistów i gorączki Pontiac. Pozapłucne postaci legionelozy spotyka się niezmiernie rzadko. Powikłania mogą występować w postaci niedodmy, wysięku, zrostów, ropni płuc, ropniaków opłucnej, przetok oskrzelowo-opłucnowych, a w konsekwencji mogą prowadzić do niewydolności wielonarządowej. W diagnostyce zakażenia Legionella pneumophila stosuje się izolację i hodowlę bakterii uzyskanych z tkanek chorego na specjalnych podłożach, metody genetyczne bądź też testy serologiczne. W leczeniu skuteczne są antybiotyki z grupy makrolidów, a w ciężkiej postaci choroby także fluorochinolony. Leczeniem alternatywnym jest kombinacja trimetoprym + sulfametoksazol. W artykule przedstawiono opis przypadku 14-letniego chłopca, który został przyjęty do Kliniki z powodu gorączki, osłabienia, wymiotów, bólów brzucha i głowy. U dziecka wykonano serię badań wyjaśniających przyczynę dolegliwości. Stwierdzono podwyższone wykładniki stanu zapalnego z towarzyszącą leukopenią i trombocytopenią. W przebiegu choroby pojawiły się kaszel i wysypka. W badaniach dodatkowych wysunięto podejrzenie zajęcia układu sercowo-naczyniowego. Podejrzewając zakażenie atypowe, do leczenia dołączono makrolid, po którym uzyskano poprawę stanu klinicznego i ustąpienie objawów. Otrzymany później wynik badania w kierunku Legionella pneumophila wskazywał na możliwość zakażenia o tej etiologii.

  20. Development of a new CARD-FISH protocol for quantification of Legionella pneumophila and its application in two hospital cooling towers.

    Science.gov (United States)

    Kirschner, A K T; Rameder, A; Schrammel, B; Indra, A; Farnleitner, A H; Sommer, R

    2012-06-01

    Open cooling towers are frequent sources of infections with Legionella pneumophila. The gold standard for the detection of Leg. pneumophila is based on cultivation lasting up to 10 days and detecting only culturable cells. Alternative fluorescence in situ hybridization (FISH) protocols have been proposed, but they result in faint fluorescence signals and lack specificity because of cross-hybridization with other Legionella species. Our aim was thus to develop a new FISH protocol for rapid and specific detection of Leg. pneumophila in water samples. A novel catalysed reporter deposition FISH (CARD-FISH) protocol for the detection of Leg. pneumophila was developed, which significantly enhanced signal intensity as well as specificity of the probe through the use of a novel competitor probe. The developed protocol was compared with the culture method for monitoring the seasonal development of culturable and nonculturable Leg. pneumophila in two hospital cooling tower systems. Seasonal fluctuations of Leg. pneumophila concentrations detected via CARD-FISH were related to the development of the total bacterial community in both cooling towers, with temperature and biocide as the main factors controlling this development. Our results clearly showed that the majority of the Leg. pneumophila cells were in a nonculturable state. Thus, detection of Leg. pneumophila with culture methods may underestimate the total numbers of Leg. pneumophila present. Rapid, sensitive and specific detection and quantification of Leg. pneumophila in water systems is prerequisite for reliable risk estimation. The new protocol significantly improves current methodology and can be used to monitor and screen for Leg. pneumophila concentrations in cooling towers or other water systems. © 2012 The Authors. Journal of Applied Microbiology © 2012 The Society for Applied Microbiology.

  1. In Vitro Response of Guinea Pig Peritoneal Macrophages to Legionella pneumophila

    Science.gov (United States)

    1981-03-01

    In Vitro Responlse of Guinea Pig Peritoneal Macrophages to Legionella pneumophila It. A. KISIIIMi~O~’ .1. Ii.,W11ITE, F. G. SIREY, V. (U.1 Mc(GANN, R...Tlhe inter- act ion between L. lincumnophila andl( peritoneal macrophages front normial guinea pigs or front animials that had survived infection was...roagglujtiniat titer) guinea pig serum to The purp~ose of this study "as to investigate contain approximately 108 organisms per ml. the phagocytic and

  2. Geostatistics – a tool applied to the distribution of Legionella pneumophila in a hospital water system

    Directory of Open Access Journals (Sweden)

    Pasqualina Laganà

    2015-12-01

    Full Text Available [b]Introduction.[/b] Legionnaires’ disease is normally acquired by inhalation of legionellae from a contaminated environmental source. Water systems of large buildings, such as hospitals, are often contaminated with legionellae and therefore represent a potential risk for the hospital population. The aim of this study was to evaluate the potential contamination of [i]Legionella pneumophila[/i] (LP in a large hospital in Italy through georeferential statistical analysis to assess the possible sources of dispersion and, consequently, the risk of exposure for both health care staff and patients. [b]Materials and Method. [/b]LP serogroups 1 and 2–14 distribution was considered in the wards housed on two consecutive floors of the hospital building. On the basis of information provided by 53 bacteriological analysis, a ‘random’ grid of points was chosen and spatial geostatistics or [i]FAIk Kriging[/i] was applied and compared with the results of classical statistical analysis. [b]Results[/b]. Over 50% of the examined samples were positive for [i]Legionella pneumophila[/i]. LP 1 was isolated in 69% of samples from the ground floor and in 60% of sample from the first floor; LP 2–14 in 36% of sample from the ground floor and 24% from the first. The iso-estimation maps show clearly the most contaminated pipe and the difference in the diffusion of the different [i]L. pneumophila[/i] serogroups. [b]Conclusion.[/b] Experimental work has demonstrated that geostatistical methods applied to the microbiological analysis of water matrices allows a better modeling of the phenomenon under study, a greater potential for risk management and a greater choice of methods of prevention and environmental recovery to be put in place with respect to the classical statistical analysis.

  3. Effect of non-Legionellaceae bacteria on the multiplication of Legionella pneumophila in potable water.

    Science.gov (United States)

    Wadowsky, R M; Yee, R B

    1985-05-01

    A naturally occurring suspension of Legionella pneumophila and associated microbiota contained three unidentified non-Legionellaceae bacteria which supported satellite growth of a subculture of L. pneumophila on an L-cysteine-deficient medium and another bacterium which did not support growth of the subculture. Washed suspensions containing 10(3), 10(5), 10(7), or 10(8) CFU of a mixture of isolates of these non-Legionellaceae bacteria failed to support the multiplication of an isolate of agar-grown L. pneumophila which had been washed and seeded into the suspensions. The suspensions which contained 10(3), 10(5), or 10(7) CFU of the non-Legionellaceae bacteria per ml appeared to enhance survival or cryptic growth of agar-grown L. pneumophila. A decline of 1.3 log CFU of L. pneumophila per ml occurred within the first week of incubation in the sample which contained 10(8) CFU of the non-Legionellaceae bacteria per ml. In contrast to these results, naturally occurring L. pneumophila multiplied in the presence of associated microbiota. The necessity to subculture L. pneumophila and the non-Legionellaceae bacteria on artificial medium to obtain pure cultures may have affected the multiplication of L. pneumophila in tap water. Alternatively, other microorganisms may be present in the naturally occurring suspension which support the growth of this bacterium.

  4. Enhanced chlorine resistance of tap water-adapted Legionella pneumophila as compared with agar medium-passaged strains.

    Science.gov (United States)

    Kuchta, J M; States, S J; McGlaughlin, J E; Overmeyer, J H; Wadowsky, R M; McNamara, A M; Wolford, R S; Yee, R B

    1985-07-01

    Previous studies have shown that bacteria maintained in a low-nutrient "natural" environment such as swimming pool water are much more resistant to disinfection by various chemical agents than strains maintained on rich media. In the present study a comparison was made of the chlorine (Cl2) susceptibility of hot-water tank isolates of Legionella pneumophila maintained in tap water and strains passaged on either nonselective buffered charcoal-yeast extract or selective differential glycine-vancomycin-polymyxin agar medium. Our earlier work has shown that environmental and clinical isolates of L. pneumophila maintained on agar medium are much more resistant to Cl2 than coliforms are. Under the present experimental conditions (21 degrees C, pH 7.6 to 8.0, and 0.25 mg of free residual Cl2 per liter, we found the tap water-maintained L. pneumophila strains to be even more resistant than the agar-passaged isolates. Under these conditions, 99% kill of tap water-maintained strains of L. pneumophila was usually achieved within 60 to 90 min compared with 10 min for agar-passaged strains. Samples from plumbing fixtures in a hospital yielded legionellae which were "super"-chlorine resistant when assayed under natural conditions. After one agar passage their resistance dropped to levels of comparable strains which had not been previously exposed to additional chlorination. These studies more closely approximate natural conditions than our previous work and show that tap water-maintained L. pneumophila is even more resistant to Cl2 than its already resistant agar medium-passaged counterpart.

  5. Monitoring of Legionella pneumophila viability after chlorine dioxide treatment using flow cytometry.

    Science.gov (United States)

    Mustapha, Pascale; Epalle, Thibaut; Allegra, Séverine; Girardot, Françoise; Garraud, Olivier; Riffard, Serge

    2015-04-01

    The viability of three Legionella pneumophila strains was monitored after chlorine dioxide (ClO2) treatment using a flow cytometric assay. Suspensions of L. pneumophila cells were submitted to increasing concentrations of ClO2. Culturable cells were still detected when using 4 mg/L, but could no longer be detected after exposure to 6 mg/L of ClO2, although viable but not culturable (VBNC) cells were found after exposure to 4-5 mg/L of ClO2. When testing whether these VBNC were infective, two of the strains were resuscitated after co-culture with Acanthamoeba polyphaga, but neither of them could infect macrophage-like cells. Copyright © 2015 Institut Pasteur. Published by Elsevier Masson SAS. All rights reserved.

  6. Protein expression, crystallization and preliminary X-ray crystallographic studies of LidA from Legionella pneumophila

    International Nuclear Information System (INIS)

    Zhu, Wenzhuang; Meng, Geng; Liu, Yong; Zhang, Feiyun; Zheng, Xiaofeng

    2011-01-01

    The crystallization of recombinant lidA, a translocated substrate of the Legionella pneumophila Dot/Icm type IV secretion system, is reported. Crystals were obtained and diffracted to 2.75 Å in space group P2 1 2 1 2 1 . LidA, a translocated substrate of the Legionella pneumophila Dot/Icm type IV secretion system, is associated with maintenance of bacterial integrity and interferes with the early secretory pathway. However, the precise mechanism of LidA in these processes remains elusive. To further investigate the structure and function of LidA, the full-length protein was successfully expressed in Escherichia coli and purified. LidA was crystallized using sitting-drop vapour diffusion and diffracted to a resolution of 2.75 Å. The crystal belonged to space group P2 1 2 1 2 1 , with unit-cell parameters a = 57.5, b = 64.5, c = 167.3 Å, α = β = γ = 90°. There is one molecule per asymmetric unit

  7. Isolation and identification of Legionella pneumophila from drinking water in Basra governorate, Iraq.

    Science.gov (United States)

    Al-Sulami, A A; Al-Taee, A M R; Yehyazarian, A A

    2013-11-01

    This study in Iraq investigated the occurrence of Legionella. pneumophila in different drinking-water sources in Basra governorate as well as the susceptibility of isolates to several antibiotics. A total of 222 water samples were collected in 2008-2009: 49 samples from water purification plants (at entry points, from precipitation tanks, from filtration tanks and at exit points), 127 samples of tap water; and 46 samples from tankers and plants supplying water by reverse osmosis. The findings confirmed the presence of L. pneumophila in sources of crude water, in general drinking water supplies and drinking water tankers. Of 258 isolates 77.1% were serotype 1 and 22.9% serotypes 2-15. All examined isolates displayed drug resistance, particularly to ampicillin, but were 100% susceptible to doxycycline. The prevalence of L. pneumophila, especially serogroup 1, is a strong indicator of unsuitability of drinking water and requires appropriate action.

  8. A Legionella pneumophila effector protein encoded in a region of genomic plasticity binds to Dot/Icm-modified vacuoles.

    Directory of Open Access Journals (Sweden)

    Shira Ninio

    2009-01-01

    Full Text Available Legionella pneumophila is an opportunistic pathogen that can cause a severe pneumonia called Legionnaires' disease. In the environment, L. pneumophila is found in fresh water reservoirs in a large spectrum of environmental conditions, where the bacteria are able to replicate within a variety of protozoan hosts. To survive within eukaryotic cells, L. pneumophila require a type IV secretion system, designated Dot/Icm, that delivers bacterial effector proteins into the host cell cytoplasm. In recent years, a number of Dot/Icm substrate proteins have been identified; however, the function of most of these proteins remains unknown, and it is unclear why the bacterium maintains such a large repertoire of effectors to promote its survival. Here we investigate a region of the L. pneumophila chromosome that displays a high degree of plasticity among four sequenced L. pneumophila strains. Analysis of GC content suggests that several genes encoded in this region were acquired through horizontal gene transfer. Protein translocation studies establish that this region of genomic plasticity encodes for multiple Dot/Icm effectors. Ectopic expression studies in mammalian cells indicate that one of these substrates, a protein called PieA, has unique effector activities. PieA is an effector that can alter lysosome morphology and associates specifically with vacuoles that support L. pneumophila replication. It was determined that the association of PieA with vacuoles containing L. pneumophila requires modifications to the vacuole mediated by other Dot/Icm effectors. Thus, the localization properties of PieA reveal that the Dot/Icm system has the ability to spatially and temporally control the association of an effector with vacuoles containing L. pneumophila through activities mediated by other effector proteins.

  9. Betekenis van Legionella-soorten voor preventiebeleid van leidingwaterinstallaties

    NARCIS (Netherlands)

    Versteegh JFM; Brandsema PS; Lodder WJ; de Roda Husman AM; Schalk JAC; van der Aa NGFM; IMG; LZO; EPI

    2009-01-01

    Het RIVM adviseert om de huidige normstelling voor het preventiebeleid van Legionella te handhaven en niet uitsluitend op Legionella pneumophila te richten. Als andere Legionella-soorten worden aangetroffen kan er ook groei van Legionella pneumophila optreden. Als er dan geen maatregelen worden

  10. Comparison of five methods for extraction of Legionella pneumophila from respiratory specimens.

    Science.gov (United States)

    Wilson, Deborah; Yen-Lieberman, Belinda; Reischl, Udo; Warshawsky, Ilka; Procop, Gary W

    2004-12-01

    The efficiencies of five commercially available nucleic acid extraction methods were evaluated for the recovery of a standardized inoculum of Legionella pneumophila in respiratory specimens (sputum and bronchoalveolar lavage [BAL] specimens). The concentrations of Legionella DNA recovered from sputa with the automated MagNA Pure (526,200 CFU/ml) and NucliSens (171,800 CFU/ml) extractors were greater than those recovered with the manual methods (i.e., Roche High Pure kit [133,900 CFU/ml], QIAamp DNA Mini kit [46,380 CFU/ml], and ViralXpress kit [13,635 CFU/ml]). The rank order was the same for extracts from BAL specimens, except that for this specimen type the QIAamp DNA Mini kit recovered more than the Roche High Pure kit.

  11. Legionella pneumophila: From potable water to treated greywater; quantification and removal during treatment.

    Science.gov (United States)

    Blanky, Marina; Rodríguez-Martínez, Sara; Halpern, Malka; Friedler, Eran

    2015-11-15

    Greywater is an alternative water source that can help alleviate stress on depleted water resources. The main options for greywater reuse are toilet flushing and garden irrigation, both producing aerosols. For that reason transmission of inhalable pathogens like Legionella present a potential risk. To improve the understanding about Legionella in greywater, we traced the pathogen seasonally from the potable water system to the final steps of the greywater treatment in four houses in northern Israel. Physicochemical and microbiological parameters were analyzed in order to assess background greywater quality and to establish possible associations with Legionella. The mean concentrations of Legionella pneumophila isolated from the potable water system were 6.4×10(2) and 5.9×10(3) cfu/l in cold and hot water respectively. By amending the ISO protocol for Legionella isolation from drinking water, we succeeded in quantifying Legionella in greywater. The mean Legionella concentrations that were found in raw, treated and treated chlorinated greywater were 1.2×10(5), 2.4×10(4) and 5.7×10(3) cfu/l respectively. While Legionella counts in potable water presented a seasonal pattern with high concentrations in summer, its counts in greywater presented an almost inversed pattern. Greywater treatment resulted in 95% decrease in Legionella counts. No significant difference was found between Legionella concentrations in potable water and the treated chlorinated greywater. These findings indicate that regarding Legionella, reusing treated chlorinated greywater would exhibit a risk that is very similar to the risk associated with using potable water for the same non-potable uses. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Genomic characterization of a large outbreak of Legionella pneumophila serogroup 1 strains in Quebec City, 2012.

    Directory of Open Access Journals (Sweden)

    Simon Lévesque

    Full Text Available During the summer of 2012, a major Legionella pneumophila serogroup 1 outbreak occurred in Quebec City, Canada, which caused 182 declared cases of Legionnaire's disease and included 13 fatalities. Legionella pneumophila serogroup 1 isolates from 23 patients as well as from 32 cooling towers located in the vicinity of the outbreak were recovered for analysis. In addition, 6 isolates from the 1996 Quebec City outbreak and 4 isolates from patients unrelated to both outbreaks were added to allow comparison. We characterized the isolates using pulsed-field gel electrophoresis, sequence-based typing, and whole genome sequencing. The comparison of patients-isolated strains to cooling tower isolates allowed the identification of the tower that was the source of the outbreak. Legionella pneumophila strain Quebec 2012 was identified as a ST-62 by sequence-based typing methodology. Two new Legionellaceae plasmids were found only in the epidemic strain. The LVH type IV secretion system was found in the 2012 outbreak isolates but not in the ones from the 1996 outbreak and only in half of the contemporary human isolates. The epidemic strains replicated more efficiently and were more cytotoxic to human macrophages than the environmental strains tested. At least four Icm/Dot effectors in the epidemic strains were absent in the environmental strains suggesting that some effectors could impact the intracellular replication in human macrophages. Sequence-based typing and pulsed-field gel electrophoresis combined with whole genome sequencing allowed the identification and the analysis of the causative strain including its likely environmental source.

  13. Three Antagonistic Cyclic di-GMP-Catabolizing Enzymes Promote Differential Dot/Icm Effector Delivery and Intracellular Survival at the Early Steps of Legionella pneumophila Infection

    Science.gov (United States)

    Allombert, Julie; Lazzaroni, Jean-Claude; Baïlo, Nathalie; Gilbert, Christophe; Charpentier, Xavier; Doublet, Patricia

    2014-01-01

    Legionella pneumophila is an intracellular pathogen which replicates within protozoan cells and can accidently infect alveolar macrophages, causing an acute pneumonia in humans. The second messenger cyclic di-GMP (c-di-GMP) has been shown to play key roles in the regulation of various bacterial processes, including virulence. While investigating the function of the 22 potential c-di-GMP-metabolizing enzymes of the L. pneumophila Lens strain, we found three that directly contribute to its ability to infect both protozoan and mammalian cells. These three enzymes display diguanylate cyclase (Lpl0780), phosphodiesterase (Lpl1118), and bifunctional diguanylate cyclase/phosphodiesterase (Lpl0922) activities, which are all required for the survival and intracellular replication of L. pneumophila. Mutants with deletions of the corresponding genes are efficiently taken up by phagocytic cells but are partially defective for the escape of the Legionella-containing vacuole (LCV) from the host degradative endocytic pathway and result in lower survival. In addition, Lpl1118 is required for efficient endoplasmic reticulum recruitment to the LCV. Trafficking and biogenesis of the LCV are dependent upon the orchestrated actions of several type 4 secretion system Dot/Icm effectors proteins, which exhibit differentially altered translocation in the three mutants. While translocation of some effectors remained unchanged, others appeared over- and undertranslocated. A general translocation offset of the large repertoire of Dot/Icm effectors may be responsible for the observed defects in the trafficking and biogenesis of the LCV. Our results suggest that L. pneumophila uses cyclic di-GMP signaling to fine-tune effector delivery and ensure effective evasion of the host degradative pathways and establishment of a replicative vacuole. PMID:24379287

  14. Plumbing system shock absorbers as a source of Legionella pneumophila.

    Science.gov (United States)

    Memish, Z A; Oxley, C; Contant, J; Garber, G E

    1992-12-01

    Water distribution systems have been demonstrated to be a major source of nosocomial legionellosis. We describe an outbreak in our institution in which a novel source of Legionella pneumophila was identified in the plumbing system. After an outbreak of 10 cases of legionellosis in our hospital, recommended measures including superheating of the hot water to 80 degrees C, hyperchlorination to 2 ppm, and flushing resulted in no new cases in the following 5 years. Recently, despite these control measures, three new cases occurred. Surveillance cultures of shower heads and water tanks were negative; cultures of tap water samples remained positive. This prompted a search for another reservoir. Shock absorbers installed within water pipes to decrease noise were suspected. One hundred twenty-five shock absorbers were removed and cultured. A total of 13 (10%) yielded heavy growth of L. pneumophila (serogroup 1). Since their removal, no new cases have been found and the percentage of positive results of random tap water culture has dropped from 20% to 5%. This is the first report that identifies shock absorbers as a possible reservoir for L. pneumophila. We recommend that institutions with endemic legionellosis assess the water system for possible removal of shock absorbers.

  15. Legionella pneumophila secretes a mitochondrial carrier protein during infection.

    Directory of Open Access Journals (Sweden)

    Pavel Dolezal

    2012-01-01

    Full Text Available The Mitochondrial Carrier Family (MCF is a signature group of integral membrane proteins that transport metabolites across the mitochondrial inner membrane in eukaryotes. MCF proteins are characterized by six transmembrane segments that assemble to form a highly-selective channel for metabolite transport. We discovered a novel MCF member, termed Legionellanucleotide carrier Protein (LncP, encoded in the genome of Legionella pneumophila, the causative agent of Legionnaire's disease. LncP was secreted via the bacterial Dot/Icm type IV secretion system into macrophages and assembled in the mitochondrial inner membrane. In a yeast cellular system, LncP induced a dominant-negative phenotype that was rescued by deleting an endogenous ATP carrier. Substrate transport studies on purified LncP reconstituted in liposomes revealed that it catalyzes unidirectional transport and exchange of ATP transport across membranes, thereby supporting a role for LncP as an ATP transporter. A hidden Markov model revealed further MCF proteins in the intracellular pathogens, Legionella longbeachae and Neorickettsia sennetsu, thereby challenging the notion that MCF proteins exist exclusively in eukaryotic organisms.

  16. Field inversion gel electrophoretic analysis of Legionella pneumophila strains associated with nosocomial legionellosis in children.

    Science.gov (United States)

    Green, M; Wald, E R; Dashefsky, B; Barbadora, K; Wadowsky, R M

    1996-01-01

    Two nosocomial cases of Legionnaires' disease occurred in children. Legionella pneumophila serogroup 1 was isolated from both patients and 30 of 39 plumbing system sites in the hospital. The patient and hospital environmental isolates yielded identical field inversion gel electrophoretic patterns which differed from patterns observed with epidemiologically unrelated strains.

  17. Free-living protozoa in drinking water supplies: community composition and role as hosts for Legionella pneumophila

    NARCIS (Netherlands)

    Valster, R.M.

    2011-01-01

    Free-living protozoa in drinking water supplies: community composition and role as hosts for Legionella pneumophila


    Free-living protozoa, which feed on bacteria, play an important role in the communities of microorganisms and invertebrates in drinking water supplies and in (warm)

  18. Knowledge to Predict Pathogens: Legionella pneumophila Lifecycle Critical Review Part I Uptake into Host Cells

    Directory of Open Access Journals (Sweden)

    Alexis L. Mraz

    2018-01-01

    Full Text Available Legionella pneumophila (L. pneumophila is an infectious disease agent of increasing concern due to its ability to cause Legionnaires’ Disease, a severe community pneumonia, and the difficulty in controlling it within water systems. L. pneumophila thrives within the biofilm of premise plumbing systems, utilizing protozoan hosts for protection from disinfectants and other environmental stressors. While there is a great deal of information regarding how L. pneumophila interacts with protozoa and human macrophages (host for human infection, the ability to use this data in a model to attempt to predict a concentration of L. pneumophila in a water system is not known. The lifecycle of L. pneumophila within host cells involves three processes: uptake, growth, and egression from the host cell. The complexity of these three processes would risk conflation of the concepts; therefore, this review details the available information regarding how L. pneumophila invades host cells (uptake within the context of data needed to model this process, while a second review will focus on growth and egression. The overall intent of both reviews is to detail how the steps in L. pneumophila’s lifecycle in drinking water systems affect human infectivity, as opposed to detailing just its growth and persistence in drinking water systems.

  19. Influence of Sampling Season and Sampling Protocol on Detection of Legionella Pneumophila Contamination in Hot Water / Paraugu Ņemšanas Sezonalitātes Un Paraugu Ņemšanas Metodes Ietekme Uz Legionella Pneumophila Kontaminācijas Noteikšanu Karstajš Ūdenī

    Directory of Open Access Journals (Sweden)

    Pūle Daina

    2016-08-01

    Full Text Available Legionella pneumophila is an environmental pathogen of engineered water systems that can cause different forms of legionellosis - from mild fever to potentially lethal pneumonia. Low concentrations of legionellae in natural habitats can increase markedly in engineered hot water systems where water temperatures are below 55 °C. In the current study, we aimed to investigate the influence of sampling season, hot water temperature and sampling protocol on occurrence of L. pneumophila. A total of 120 hot water samples from 20 apartment buildings were collected in two sampling periods - winter 2014 (n = 60 and summer 2015 (n = 60. Significantly higher occurrence of L. pneumophila was observed in summer 2015. Significant differences in temperature for negative and positive samples were not observed, which can be explained by low water temperatures at the point of water consumption. Temperature above 55 °C was observed only once, for all other sampling events it ranged from 14 °C to 53 °C.

  20. A Preliminary study on the prevalence of Legionella pneumophila infection in Lebanon

    International Nuclear Information System (INIS)

    Hamze, M.; Mallat, H.; Mokhbat, J.

    2009-01-01

    After the first outbreak of Legionnaire disease was described for the first time in1976, legionellosis has been increasingly recognized in association with many outbreaks, both community and hospital acquired. This disease remains a model of water borne transmission. In Lebanon, no report has yet been published on the prevalence of Legionella pneumophila infections. This study aims to evaluate the prevalence of legionellosis in hospitalized patients with community acquired pneumonia (CAP) and in patients with nosocomial pneumonia (HAP). The study was conducted between April 2004 and August 2007. Eleven community hospitals participated to this endeavour. Laboratory evaluation was conducted in two centers (Middle East Health Institute, Bsalim, Lebanon and Nini Hospital, Tripoli, Lebanon). Two hundred and forty two urinary samples and ninety one pulmonary samples from 242 patients were analyzed. The age range was 16 to 71 years. Two hundred and fifteen were from community acquired pneumonias and twenty seven were nosocomially acquired in intensive care units. The urinary antigen was investigated in 242 patients; the Binax kit ® was used in this research. In lung secretions of 91 patients, the presence of Legionella pneumophila was searched for using direct immunofluorescence method and culture. Among the 215 urinary samples from patients with CAP, three were positive for Legionella antigen with a prevalence of 1.4 %. Among the 27 patients with HAP, one was positive for Legionella antigen with a prevalence of 3.7%. This preliminary study reveals the fact that legionellosis is indeed present in Lebanon, hence the importance of considering it in the work-up and the management of patients with pneumonia. Hospital laboratories should therefore routin ely search for this pathogen through at least urinary antigen detection. Health authorities should also enforce microbiological regulations concerning water sanitation in hospitals and in the community to prevent the

  1. Alternative sources of Legionella bacteria

    NARCIS (Netherlands)

    van Heijnsbergen, H.H.L.

    2017-01-01

    Legionella bacteria can cause Legionnaires’ disease (LD) in humans. Symptoms of LD can range from mild disease to severe pneumonia with sometimes fatal outcome. In the Netherlands, the most important infective agent is Legionella pneumophila. L. pneumophila infection is associated with aquatic

  2. Rate of Legionella pneumophila colonization in hospital hot water network after time flow taps installation.

    Science.gov (United States)

    Totaro, M; Valentini, P; Costa, A L; Giorgi, S; Casini, B; Baggiani, A

    2018-01-01

    In hospital water systems legionellae may be resistant to disinfectants in pipework, which is a problem particularly in areas where there is low flow or stagnation of water. We evaluated legionella colonization of a water network of an Italian hospital after time flow taps (TFTs) installation in proximity to dead legs. The water volume flushed was 64 L/day from May 2016, and 192 L/day from December 2016. Before TFTs installation, Legionella pneumophila sg2-14 was detected in all points (4 × 10 4  ± 3.1 × 10 4  cfu/L). All sites remained positive (2.9 × 10 4  ± 1.9 × 10 4  cfu/L) through November 2016. From December 2016 legionella persisted in one point only (2 × 10 2 to 6.8 × 10 3  cfu/L). TFTs with chemical disinfection may reduce legionella colonization associated with dead legs. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  3. Non-opsonic phagocytosis of Legionella pneumophila by macrophages is mediated by phosphatidylinositol 3-kinase.

    Directory of Open Access Journals (Sweden)

    Souvenir D Tachado

    Full Text Available BACKGROUND: Legionella pneumophila, is an intracellular pathogen that causes Legionnaires' disease in humans, a potentially lethal pneumonia. L. pneumophila has the ability to enter and replicate in the host and is essential for pathogenesis. METHODOLOGY/PRINCIPAL FINDINGS: Phagocytosis was measured by cell invasion assays. Construction of PI3K mutant by PCR cloning and expression of dominant negative mutant was detected by Western blot. PI3K activity was measured by 32P labeling and detection of phospholipids products by thin layer chromatography. Infection of macrophages with virulent L. pneumophila stimulated the formation of phosphatidylinositol 3-phosphate (PIP3, a phosphorylated lipid product of PI3K whereas two structurally distinct phosphatidylinositol 3 kinase (PI3K inhibitors, wortmannin and LY294002, reduced L. pneumophila entry into macrophages in a dose-dependent fashion. Furthermore, PI3K activation led to Akt stimulation, a serine/threonine kinase, which was also inhibited by wortmannin and LY294002. In contrast, PI3K and protein kinase B (PKB/Akt activities were lower in macrophages infected with an avirulent bacterial strain. Only virulent L. pneumophila increased lipid kinase activity present in immunoprecipitates of the p85alpha subunit of class I PI3K and tyrosine phosphorylated proteins. In addition, macrophages expressing a specific dominant negative mutant of PI3K reduced L. pneumophila entry into these cells. CONCLUSION/SIGNIFICANCE: Entry of L. pneumophila is mediated by PI3K/Akt signaling pathway. These results suggest an important role for PI3K and Akt in the L. pneumophila infection process. They point to possible novel strategies for undermining L. pneumophila host uptake and reducing pathogenesis of Legionnaires' disease.

  4. Hot water systems as sources of Legionella pneumophila in hospital and nonhospital plumbing fixtures

    Energy Technology Data Exchange (ETDEWEB)

    Wadowsky, R.M.; Yee, R.B.; Mezmar, L.; Wing, E.J.; Dowling, J.N.

    1982-05-01

    Samples obtained from plumbing systems of hospitals, nonhospital institutions, and homes were cultured for Legionella spp. by plating the samples directly on a selective medium. Swab samples were taken from the inner surfaces of faucet assemblies (aerators, spouts, and valve seats), showerheads, and shower pipes. Water and sediment were collected from the bottom of hot-water tanks. Legionella pnenumophila serogroups 1.5, and 6 were recovered from plubming fixtures of the hospitals and nonhospital institutions and one of five homes. The legionellae (7 to 13,850 colony-forming units per ml) were also present in water and sediment from hot-water tanks maintained at 30 to 54/sup 0/C, but not in those maintained at 71 and 77/sup 0/C. Legionella micdadei was isolated from one tank. Thus legionellae are present in hot-water tanks which are maintained at warm temperatures or whose design results in warm temperatures at the bottom of the tanks. We hypothesize that hot-water tanks are a breeding site and a major source of L. pneumophila for the contamination of plumbing systems. The existence of these bacteria in the plumbing systems and tanks was not necessarily associated with disease. The extent of the hazard of this contamination needs to be delineated.

  5. Crucial Role of Legionella pneumophila TolC in the Inhibition of Cellular Trafficking in the Protistan Host Paramecium tetraurelia.

    Science.gov (United States)

    Nishida, Takashi; Hara, Naho; Watanabe, Kenta; Shimizu, Takashi; Fujishima, Masahiro; Watarai, Masahisa

    2018-01-01

    Legionella pneumophila is a facultative intracellular Gram-negative bacterium, which is a major causative agent of Legionnaires' disease. In the environment, this bacterium survives in free-living protists such as amoebae and Tetrahymena . The association of L. pneumophila and protists leads to the replication and spread of this bacterium. Thus, from a public health perspective, their association can enhance the risk of L. pneumophila infection for humans. Paramecium spp. are candidates of natural hosts of L. pneumophila , but their detailed relationships remain unclear. In the present study, we used an environmental strain, L. pneumophila Ofk308 (Ofk308) and Paramecium tetraurelia st110-1a to reveal the relationship between L. pneumophila and Paramecium spp. Ofk308 was cytotoxic to P. tetraurelia in an infection-dependent manner. We focused on TolC, a component of the type I secretion system, which is a virulence factor of L. pneumophila toward protists and found that cytotoxicity was dependent on TolC but not on other T1SS components. Further, the number of bacteria in P. tetraurelia was not associated with cytotoxicity and TolC was not involved in the mechanism of resistance against the digestion of P. tetraurelia in Ofk308. We used a LysoTracker to evaluate the maturation process of P. tetraurelia phagosomes containing Ofk308. We found that there was no difference between Ofk308 and the tolC -deletion mutant. To assess the phagocytic activity of P. tetraurelia , Texas Red-conjugated dextran-uptake assays were performed. Ofk308 inhibited phagosome formation by P. tetraurelia through a TolC-dependent mechanism. Further, we evaluated the excretion of Legionella -containing vacuoles from P. tetraurelia . We found that P. tetraurelia failed to excrete undigested Ofk308 and that Ofk308 remained within cells through a TolC-dependent mechanism. Our results suggest that TolC is essential for L. pneumophila to remain within Paramecium cells and to show cytotoxicity

  6. Crucial Role of Legionella pneumophila TolC in the Inhibition of Cellular Trafficking in the Protistan Host Paramecium tetraurelia

    Directory of Open Access Journals (Sweden)

    Takashi Nishida

    2018-04-01

    Full Text Available Legionella pneumophila is a facultative intracellular Gram-negative bacterium, which is a major causative agent of Legionnaires’ disease. In the environment, this bacterium survives in free-living protists such as amoebae and Tetrahymena. The association of L. pneumophila and protists leads to the replication and spread of this bacterium. Thus, from a public health perspective, their association can enhance the risk of L. pneumophila infection for humans. Paramecium spp. are candidates of natural hosts of L. pneumophila, but their detailed relationships remain unclear. In the present study, we used an environmental strain, L. pneumophila Ofk308 (Ofk308 and Paramecium tetraurelia st110-1a to reveal the relationship between L. pneumophila and Paramecium spp. Ofk308 was cytotoxic to P. tetraurelia in an infection-dependent manner. We focused on TolC, a component of the type I secretion system, which is a virulence factor of L. pneumophila toward protists and found that cytotoxicity was dependent on TolC but not on other T1SS components. Further, the number of bacteria in P. tetraurelia was not associated with cytotoxicity and TolC was not involved in the mechanism of resistance against the digestion of P. tetraurelia in Ofk308. We used a LysoTracker to evaluate the maturation process of P. tetraurelia phagosomes containing Ofk308. We found that there was no difference between Ofk308 and the tolC-deletion mutant. To assess the phagocytic activity of P. tetraurelia, Texas Red-conjugated dextran-uptake assays were performed. Ofk308 inhibited phagosome formation by P. tetraurelia through a TolC-dependent mechanism. Further, we evaluated the excretion of Legionella-containing vacuoles from P. tetraurelia. We found that P. tetraurelia failed to excrete undigested Ofk308 and that Ofk308 remained within cells through a TolC-dependent mechanism. Our results suggest that TolC is essential for L. pneumophila to remain within Paramecium cells and to show

  7. Prevalence of Infection-Competent Serogroup 6 Legionella pneumophila within Premise Plumbing in Southeast Michigan.

    Science.gov (United States)

    Byrne, Brenda G; McColm, Sarah; McElmurry, Shawn P; Kilgore, Paul E; Sobeck, Joanne; Sadler, Rick; Love, Nancy G; Swanson, Michele S

    2018-02-06

    Coinciding with major changes to its municipal water system, Flint, MI, endured Legionnaires' disease outbreaks in 2014 and 2015. By sampling premise plumbing in Flint in the fall of 2016, we found that 12% of homes harbored legionellae, a frequency similar to that in residences in neighboring areas. To evaluate the genetic diversity of Legionella pneumophila in Southeast Michigan, we determined the sequence type (ST) and serogroup (SG) of the 18 residential isolates from Flint and Detroit, MI, and the 33 clinical isolates submitted by hospitals in three area counties in 2013 to 2016. Common to one environmental and four clinical samples were strains of L. pneumophila SG1 and ST1, the most prevalent ST worldwide. Among the Flint premise plumbing isolates, 14 of 16 strains were of ST367 and ST461, two closely related SG6 strain types isolated previously from patients and corresponding environmental samples. Each of the representative SG1 clinical strains and SG6 environmental isolates from Southeast Michigan infected and survived within macrophage cultures at least as well as a virulent laboratory strain, as judged by microscopy and by enumerating CFU. Likewise, 72 h after infection, the yield of viable-cell counts increased >100-fold for each of the representative SG1 clinical isolates, Flint premise plumbing SG6 ST367 and -461 isolates, and two Detroit residential isolates. We verified by immunostaining that SG1-specific antibody does not cross-react with the SG6 L. pneumophila environmental strains. Because the widely used urinary antigen diagnostic test does not readily detect non-SG1 L. pneumophila , Legionnaires' disease caused by SG6 L. pneumophila is likely underreported worldwide. IMPORTANCE L. pneumophila is the leading cause of disease outbreaks associated with drinking water in the United States. Compared to what is known of the established risks of colonization within hospitals and hotels, relatively little is known about residential exposure to

  8. Legionella pneumophila infection of Drosophila S2 cells induces only minor changes in mitochondrial dynamics.

    Directory of Open Access Journals (Sweden)

    Elizabeth Wen Sun

    Full Text Available During infection of cells by Legionella pneumophila, the bacterium secretes a large number of effector proteins into the host cell cytoplasm, allowing it to alter many cellular processes and make the vacuole and the host cell into more hospitable environments for bacterial replication. One major change induced by infection is the recruitment of ER-derived vesicles to the surface of the vacuole, where they fuse with the vacuole membrane and prevent it from becoming an acidified, degradative compartment. However, the recruitment of mitochondria to the region of the vacuole has also been suggested by ultrastructural studies. In order to test this idea in a controlled and quantitative experimental system, and to lay the groundwork for a genome-wide screen for factors involved in mitochondrial recruitment, we examined the behavior of mitochondria during the early stages of Legionella pneumophila infection of Drosophila S2 cells. We found that the density of mitochondria near vacuoles formed by infection with wild type Legionella was not different from that found in dotA(- mutant-infected cells during the first 4 hours after infection. We then examined 4 parameters of mitochondrial motility in infected cells: velocity of movement, duty cycle of movement, directional persistence and net direction. In the 4 hours following infection, most of these measures were indistinguishable between wild type and dotA(-.infection. However, wild type Legionella did induce a modest shift in the velocity distribution toward faster movement compared dotA(- infection, and a small downward shift in the duty cycle distribution. In addition, wild type infection produced mitochondrial movement that was biased in the direction of the bacterial vacuole relative to dotA-, although not enough to cause a significant accumulation within 10 um of the vacuole. We conclude that in this host cell, mitochondria are not strongly recruited to the vacuole, nor is their motility

  9. Master manipulators: an update on Legionella pneumophila Icm/Dot translocated substrates and their host targets

    Science.gov (United States)

    Isaac, Dervla T; Isberg, Ralph

    2014-01-01

    Macrophages are the front line of immune defense against invading microbes. Microbes, however, have evolved numerous and diverse mechanisms to thwart these host immune defenses and thrive intracellularly. Legionella pneumophila, a Gram-negative pathogen of amoebal and mammalian phagocytes, is one such microbe. In humans, it causes a potentially fatal pneumonia referred to as Legionnaires' disease. Armed with the Icm/Dot type IV secretion system, which is required for virulence, and approximately 300 translocated proteins, Legionella is able to enter host cells, direct the biogenesis of its own vacuolar compartment, and establish a replicative niche, where it grows to high levels before lysing the host cell. Efforts to understand the pathogenesis of this bacterium have focused on characterizing the molecular activities of its many effectors. In this article, we highlight recent strides that have been made in understanding how Legionella effectors mediate host-pathogen interactions. PMID:24762308

  10. Distinct difference of flaA genotypes of Legionella pneumophila between isolates from bath water and cooling tower water.

    Science.gov (United States)

    Amemura-Maekawa, Junko; Kura, Fumiaki; Chang, Bin; Suzuki-Hashimoto, Atsuko; Ichinose, Masayuki; Endo, Takuro; Watanabe, Haruo

    2008-09-01

    To investigate the genetic difference of Legionella pneumophila in human-made environments, we collected isolates of L. pneumophila from bath water (n = 167) and cooling tower water (n = 128) primarily in the Kanto region in 2001 and 2005. The environmental isolates were serogrouped and sequenced for a target region of flaA. A total of 14 types of flaA genotypes were found: 10 from cooling tower water and nine from bath water. The flaA genotypes of isolates from cooling tower water were quite different from those of bath water.

  11. Comparison of pulsed corona plasma and pulsed electric fields for the decontamination of water containing Legionella pneumophila as model organism.

    Science.gov (United States)

    Banaschik, Robert; Burchhardt, Gerhard; Zocher, Katja; Hammerschmidt, Sven; Kolb, Juergen F; Weltmann, Klaus-Dieter

    2016-12-01

    Pulsed corona plasma and pulsed electric fields were assessed for their capacity to kill Legionella pneumophila in water. Electrical parameters such as in particular dissipated energy were equal for both treatments. This was accomplished by changing the polarity of the applied high voltage pulses in a coaxial electrode geometry resulting in the generation of corona plasma or an electric field. For corona plasma, generated by high voltage pulses with peak voltages of +80kV, Legionella were completely killed, corresponding to a log-reduction of 5.4 (CFU/ml) after a treatment time of 12.5min. For the application of pulsed electric fields from peak voltages of -80kV a survival of log 2.54 (CFU/ml) was still detectable after this treatment time. Scanning electron microscopy images of L. pneumophila showed rupture of cells after plasma treatment. In contrast, the morphology of bacteria seems to be intact after application of pulsed electric fields. The more efficient killing for the same energy input observed for pulsed corona plasma is likely due to induced chemical processes and the generation of reactive species as indicated by the evolution of hydrogen peroxide. This suggests that the higher efficacy and efficiency of pulsed corona plasma is primarily associated with the combined effect of the applied electric fields and the promoted reaction chemistry. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. New crystal forms of NTPDase1 from the bacterium Legionella pneumophila

    International Nuclear Information System (INIS)

    Zebisch, Matthias; Schäfer, Petra; Lauble, Peter; Sträter, Norbert

    2013-01-01

    The soluble NTPDase1 from L. pneumophila was crystallized in six crystal forms and the structure was solved using a sulfur SAD approach. Nucleoside triphosphate diphosphohydrolases (NTPDases) are a large class of nucleotidases that hydrolyze the (γ/β)- and (β/α)-anhydride bonds of nucleoside triphosphates and diphosphates, respectively. NTPDases are found throughout the eukaryotic domain. In addition, a very small number of members can be found in bacteria, most of which live as parasites of eukaryotic hosts. NTPDases of intracellular and extracellular parasites are emerging as important regulators for the survival of the parasite. To deepen the knowledge of the structure and function of this enzyme class, recombinant production of the NTPDase1 from the bacterium Legionella pneumophila has been established. The protein could be crystallized in six crystal forms, of which one has been described previously. The crystals diffracted to resolutions of between 1.4 and 2.5 Å. Experimental phases determined by a sulfur SAD experiment using an orthorhombic crystal form produced an interpretable electron-density map

  13. Deactivation of Legionella Pneumophila in municipal wastewater by ozone generated in arrays of microchannel plasmas

    Science.gov (United States)

    Dong, Shengkun; Li, Jun; Kim, Min-Hwan; Cho, Jinhoon; Park, Sung-Jin; Nguyen, Thanh H.; Eden, J. Gary

    2018-06-01

    A greater than four log10 reduction in the concentration of Legionella pneumophila in municipal wastewater has been achieved in 1 min with ozone produced by a microchannel plasma reactor. Requiring less than 22 W of electrical power, and ambient air as the feedstock gas, the microplasma ozone generator is robust and a promising alternative to conventional corona and dielectric barrier discharge (DBD) technologies. Contrary to previous studies, the Ct model for pathogen deactivation (i.e. rate proportional to the product of the available disinfectant concentration and the exposure duration) is found to be valid for L. pneumophila. Accordingly, wastewater-specific Ct equations have been developed to predict the deactivation of L. pneumophila in the secondary wastewater environment. Inactivation of this pathogen was found to be dependent on temperature only in the absence of wastewater organic matter (WOM). In the presence of WOM, pathogen deactivation is controlled by the disinfection contact time, initial ozone concentration (varied between 15 and 281 µg l‑1), and initial WOM loading. The data reported here will assist in the implementation of plasma ozone generators for L. pneumophila deactivation in cooling towers, point-of-use systems, and wastewater reclamation facilities.

  14. [Investigation of Legionella pneumophila seropositivity in the professional long distance drivers as a risky occupation].

    Science.gov (United States)

    Polat, Yusuf; Ergin, Cağri; Kaleli, Ilknur; Pinar, Ahmet

    2007-04-01

    Contaminated water sources, reservoirs and systems such as evaporative condensers of air-conditioners are known to be the main transmission routes of Legionella spp. which are ubiquitous aquatic bacteria. By virtue of this point the aim of this study was to investigate the rate of Legionella pneumophila seropositivity in a profession considered as risky due to the direct and prolonged exposure to air-conditioning and air-circulating systems. For this purpose, in the period of February-August 2004 a total of 79 male subjects (63 were bus drivers and 16 were driver assistants) who were continously travelling to two different route (South part as hot climate and Middle/North parts as cold climate of Turkey) from Denizli province coach station (a province located in internal Aegian where accepted as crossroads), were included to the study. The mean age and mean working duration of bus drivers were 43.0 +/- 1.1 years and 20.0 +/- 1.1 years, respectively, while these values were 22.5 +/- 0.9 years and 4.0 +/- 0.6 years, respectively, for the drivers' assistants. The serum samples collected from the subjects were screened by a commercial indirect immunofluorescence method (Euroimmun, Germany) using L. pneumophila serogrup 1-14 antigens for the presence of specific antibodies. Additionally, air-conditioners' moisture exhaust samples of the busses in which seropositive subjects travelling with have been examined by culture and 5S rRNA gene targeted polymerase chain reaction (PCR) methods, for the presence of Legionella spp. The overall L. pneumophila seropositivity rate was detected as 15.2% (12/79). This rate was 19% (12/63) for bus drivers while all of the drivers' assistants were found seronegative. The seropositivity rate was found statistically higher in the personnel who were travelling to the hot climates (10/36, 27.8%) than those who travel to cold climates (2/43, 4.6%), (p travel. Our data indicated that long distance bus drivers were chronically exposed to this

  15. Impact of Chlorine and Heat on the Survival of Hartmannella vermiformis and Subsequent Growth of Legionella pneumophila.

    Science.gov (United States)

    Kuchta, J M; Navratil, J S; Shepherd, M E; Wadowsky, R M; Dowling, J N; States, S J; Yee, R B

    1993-12-01

    Hartmannella vermiformis, a common amoebal inhabitant of potable-water systems, supports intracellular multiplication of Legionella pneumophila and is probably important in the transportation and amplification of legionellae within these systems. To provide a practical guide for decontamination of potable-water systems, we assessed the chlorine and heat resistance of H. vermiformis. H. vermiformis cysts and trophozoites were treated independently with chlorine at concentrations of 2.0 to 10.0 ppm for 30 min and then cocultured with L. pneumophila. Both cysts and trophozoites were sensitive to concentrations between 2.0 and 4.0 ppm and above (trophozoites somewhat more so than cysts), and 10.0 ppm was lethal to both forms. Hartmannellae treated with chlorine up to a concentration of 4.0 ppm supported the growth of legionellae. To determine whether heat would be an effective addendum to chlorine treatment of amoebae, hartmannellae were subjected to temperatures of 55 and 60 degrees C for 30 min and alternatively to 50 degrees C followed by treatment with chlorine at a concentration of 2 ppm. Fewer than 0.05% of the amoebae survived treatment at 55 degrees C, and there were no survivors at 60 degrees C. Pretreatment at 50 degrees C appeared to make hartmannella cysts more susceptible to chlorine but did not further reduce the concentration of trophozoites.

  16. Gezondheidsaspecten van Legionella in water

    NARCIS (Netherlands)

    Schets FM; Roda Husman AM de; MGB

    2004-01-01

    Legionella pneumophila is a cause of severe pneumonia in humans. Legionella bacteria are found in all freshwater environments. Particularly in artificial environments people may be exposed to Legionella containing aerosols. In this brief overview of the state of the art of Legionella research it

  17. Multiplex real-time PCR assay for Legionella species.

    Science.gov (United States)

    Kim, Seung Min; Jeong, Yoojung; Sohn, Jang Wook; Kim, Min Ja

    2015-12-01

    Legionella pneumophila serogroup 1 (sg1) accounts for the majority of infections in humans, but other Legionella species are also associated with human disease. In this study, a new SYBR Green I-based multiplex real-time PCR assay in a single reaction was developed to allow the rapid detection and differentiation of Legionella species by targeting specific gene sequences. Candidate target genes were selected, and primer sets were designed by referring to comparative genomic hybridization data of Legionella species. The Legionella species-specific groES primer set successfully detected all 30 Legionella strains tested. The xcpX and rfbA primers specifically detected L. pneumophila sg1-15 and L. pneumophila sg1, respectively. In addition, this assay was validated by testing clinical samples and isolates. In conclusion, this novel multiplex real-time PCR assay might be a useful diagnostic tool for the rapid detection and differentiation of Legionella species in both clinical and epidemiological studies. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Sequencing illustrates the transcriptional response of Legionella pneumophila during infection and identifies seventy novel small non-coding RNAs.

    LENUS (Irish Health Repository)

    Weissenmayer, Barbara A

    2011-01-01

    Second generation sequencing has prompted a number of groups to re-interrogate the transcriptomes of several bacterial and archaeal species. One of the central findings has been the identification of complex networks of small non-coding RNAs that play central roles in transcriptional regulation in all growth conditions and for the pathogen\\'s interaction with and survival within host cells. Legionella pneumophila is a gram-negative facultative intracellular human pathogen with a distinct biphasic lifestyle. One of its primary environmental hosts in the free-living amoeba Acanthamoeba castellanii and its infection by L. pneumophila mimics that seen in human macrophages. Here we present analysis of strand specific sequencing of the transcriptional response of L. pneumophila during exponential and post-exponential broth growth and during the replicative and transmissive phase of infection inside A. castellanii. We extend previous microarray based studies as well as uncovering evidence of a complex regulatory architecture underpinned by numerous non-coding RNAs. Over seventy new non-coding RNAs could be identified; many of them appear to be strain specific and in configurations not previously reported. We discover a family of non-coding RNAs preferentially expressed during infection conditions and identify a second copy of 6S RNA in L. pneumophila. We show that the newly discovered putative 6S RNA as well as a number of other non-coding RNAs show evidence for antisense transcription. The nature and extent of the non-coding RNAs and their expression patterns suggests that these may well play central roles in the regulation of Legionella spp. specific traits and offer clues as to how L. pneumophila adapts to its intracellular niche. The expression profiles outlined in the study have been deposited into Genbank\\'s Gene Expression Omnibus (GEO) database under the series accession GSE27232.

  19. Effect of temperature, pH, and oxygen level on the multiplication of naturally occurring Legionella pneumophila in potable water.

    Science.gov (United States)

    Wadowsky, R M; Wolford, R; McNamara, A M; Yee, R B

    1985-05-01

    A water culture containing naturally occurring Legionella pneumophila and associated microbiota was maintained in the laboratory by serially transferring the culture in tap water which had been sterilized by membrane filtration. Successful maintenance of the water culture depended upon transferring the culture when the growth of L. pneumophila was in the late-exponential to early-stationary phase. The water culture was used as a source of naturally occurring bacteria to determine some of the parameters which affect the multiplication of L. pneumophila in tap water. Naturally occurring L. pneumophila multiplied at a temperature between 25 and 37 degrees C, at pH levels of 5.5 to 9.2, and at concentrations of dissolved oxygen of 6.0 to 6.7 mg/liter. Multiplication did not occur in tap water which contained less than 2.2 mg of dissolved oxygen per liter. An association was observed between the multiplication of L. pneumophila and the non-Legionellaceae bacteria which were also present in the water culture. The method of preserving naturally occurring L. pneumophila and associated microbiota may facilitate studies on the symbiosis of L. pneumophila with other microorganisms.

  20. Legionella-protozoa-nematode interactions in aquatic biofilms and influence of Mip on Caenorhabditis elegans colonization.

    Science.gov (United States)

    Rasch, Janine; Krüger, Stefanie; Fontvieille, Dominique; Ünal, Can M; Michel, Rolf; Labrosse, Aurélie; Steinert, Michael

    2016-09-01

    Legionella pneumophila, the causative agent of Legionnaireś disease, is naturally found in aquatic habitats. The intracellular life cycle within protozoa pre-adapted the "accidental" human pathogen to also infect human professional phagocytes like alveolar macrophages. Previous studies employing the model organism Caenorhabditis elegans suggest that also nematodes might serve as a natural host for L. pneumophila. Here, we report for the first time from a natural co-habitation of L. pneumophila and environmental nematode species within biofilms of a warm water spring. In addition, we identified the protozoan species Oxytricha bifaria, Stylonychia mytilus, Ciliophrya sp. which have never been described as potential interaction partners of L. pneumophila before. Modeling and dissection of the Legionella-protozoa-nematode interaction revealed that C. elegans ruptures Legionella-infected amoebal cells and by this means incorporate the pathogen. Further infection studies revealed that the macrophage infectivity potentiator (Mip) protein of L. pneumophila, which is known to bind collagen IV during human lung infection, promotes the colonization of the intestinal tract of L4 larvae of C. elegans and negatively influences the life span of the worms. The Mip-negative L. pneumophila mutant exhibited a 32-fold reduced colonization rate of the nematodes after 48h when compared to the wild-type strain. Taken together, these studies suggest that nematodes may serve as natural hosts for L. pneumophila, promote their persistence and dissemination in the environment, and co-evolutionarily pre-adapt the pathogen for interactions with extracellular constituents of human lung tissue. Copyright © 2016 Elsevier GmbH. All rights reserved.

  1. Genome-scale identification of Legionella pneumophila effectors using a machine learning approach.

    Directory of Open Access Journals (Sweden)

    David Burstein

    2009-07-01

    Full Text Available A large number of highly pathogenic bacteria utilize secretion systems to translocate effector proteins into host cells. Using these effectors, the bacteria subvert host cell processes during infection. Legionella pneumophila translocates effectors via the Icm/Dot type-IV secretion system and to date, approximately 100 effectors have been identified by various experimental and computational techniques. Effector identification is a critical first step towards the understanding of the pathogenesis system in L. pneumophila as well as in other bacterial pathogens. Here, we formulate the task of effector identification as a classification problem: each L. pneumophila open reading frame (ORF was classified as either effector or not. We computationally defined a set of features that best distinguish effectors from non-effectors. These features cover a wide range of characteristics including taxonomical dispersion, regulatory data, genomic organization, similarity to eukaryotic proteomes and more. Machine learning algorithms utilizing these features were then applied to classify all the ORFs within the L. pneumophila genome. Using this approach we were able to predict and experimentally validate 40 new effectors, reaching a success rate of above 90%. Increasing the number of validated effectors to around 140, we were able to gain novel insights into their characteristics. Effectors were found to have low G+C content, supporting the hypothesis that a large number of effectors originate via horizontal gene transfer, probably from their protozoan host. In addition, effectors were found to cluster in specific genomic regions. Finally, we were able to provide a novel description of the C-terminal translocation signal required for effector translocation by the Icm/Dot secretion system. To conclude, we have discovered 40 novel L. pneumophila effectors, predicted over a hundred additional highly probable effectors, and shown the applicability of machine

  2. Gezondheidsaspecten van Legionella in water

    NARCIS (Netherlands)

    Schets FM; de Roda Husman AM; MGB

    2004-01-01

    Legionella pneumophila is een veroorzaker van ernstige longontsteking bij mensen. Legionella bacterien blijken overal in waterige milieus aanwezig te zijn. Met name in kunstmatige waterige milieus kunnen mensen blootgesteld worden aan aerosolen waarin Legionella aanwezig is. Dit beknopte

  3. Genetic Characterization of Legionella pneumophila Isolated from a Common Watershed in Comunidad Valenciana, Spain.

    Science.gov (United States)

    Sánchez-Busó, Leonor; Coscollá, Mireia; Pinto-Carbó, Marta; Catalán, Vicente; González-Candelas, Fernando

    2013-01-01

    Legionella pneumophila infects humans to produce legionellosis and Pontiac fever only from environmental sources. In order to establish control measures and study the sources of outbreaks it is essential to know extent and distribution of strain variants of this bacterium in the environment. Sporadic and outbreak-related cases of legionellosis have been historically frequent in the Comunidad Valenciana region (CV, Spain), with a high prevalence in its Southeastern-most part (BV). Environmental investigations for the detection of Legionella pneumophila are performed in this area routinely. We present a population genetics study of 87 L. pneumophila strains isolated in 13 different localities of the BV area irrigated from the same watershed and compare them to a dataset of 46 strains isolated in different points of the whole CV. Our goal was to compare environmental genetic variation at two different geographic scales, at county and regional levels. Genetic diversity, recombination and population structure were analyzed with Sequence-Based Typing data and three intergenic regions. The results obtained reveal a low, but detectable, level of genetic differentiation between both datasets, mainly, but not only, attributed to the occurrence of unusual variants of the neuA locus present in the BV populations. This differentiation is still detectable when the 10 loci considered are analyzed independently, despite the relatively high incidence of the most common genetic variant in this species, sequence type 1 (ST-1). However, when the genetic data are considered without their associated geographic information, four major groups could be inferred at the genetic level which did not show any correlation with sampling locations. The overall results indicate that the population structure of these environmental samples results from the joint action of a global, widespread ST-1 along with genetic differentiation at shorter geographic distances, which in this case are related to

  4. Roles of iron in the survival, growth, and pathogenesis of Legionella pneumophila

    International Nuclear Information System (INIS)

    Quinn, F.D.

    1985-01-01

    The essentially of iron for living cells has long been recognized, and the availability of host-iron has been proposed as a contributing factor to virulence in bacterial, fungal, and protozoan infections. The mechanism by which legionella pneumophila causes disease is unknown. Growth of fresh clinical or environmental isolates in pure culture requires 20 times more iron than is needed for most other bacteria. Thus, increased plasma iron levels may be needed for multiplication within human hosts. It was observed that: (1) this organism can be more readily deprived of iron by iron binding agents than all other bacteria studied, and this inhibition can be reversed by the addition of iron; (2) normal human blood serum kills L. pneumophila and the bactericidal action is decreased when complement is inactivated or enough iron to saturate serum transferrin is added to the system; (3) in assays with a radioactive isotope of iron ( 55 Fe), no specific iron sequestering system was detected; (4) in analysis of outer membrane proteins with 55 Fe, SDS-polyacrylamide gel electrophoresis, and autoradiography, no specific outer membrane proteins responsible for iron acquisition were observed; and (5) in assays for protease, iron does not stimulate production of extracellular proteases. These observations indicate that L. pneumophila has no specific iron uptake mechanism, but instead relies on passive diffusion and/or non-specific mechanisms to obtain its iron

  5. The many forms of a pleomorphic bacterial pathogen – The developmental network of Legionella pneumophila

    Directory of Open Access Journals (Sweden)

    Peter eRobertson

    2014-12-01

    Full Text Available Legionella pneumophila is a natural intracellular bacterial parasite of free-living freshwater protozoa and an accidental human pathogen that causes Legionnaires’ disease. L. pneumophila differentiates, and does it in style. Recent experimental data on L. pneumophila’s differentiation point at the existence of a complex network that involves many developmental forms. We intend readers to: (i understand the biological relevance of L. pneumophila’s forms found in freshwater and their potential to transmit Legionnaires’ disease, and (ii learn that the common depiction of L. pneumophila’s differentiation as a biphasic developmental cycle that alternates between a replicative and a transmissive form is but an oversimplification of the actual process. Our specific objectives are to provide updates on the molecular factors that regulate L. pneumophila’s differentiation (section 2, and describe the developmental network of L. pneumophila (section 3, which for clarity’s sake we have dissected into five separate developmental cycles. Finally, since each developmental form seems to contribute differently to the human pathogenic process and the transmission of Legionnaires’ disease, readers are presented with a challenge to develop novel methods to detect the various L. pneumophila forms present in water (section 4, as a means to improve our assessment of risk and more effectively prevent legionellosis outbreaks.

  6. Distribution of Legionella pneumophila bacteria and Naegleria and Hartmannella amoebae in thermal saline baths used in balneotherapy.

    Science.gov (United States)

    Zbikowska, Elżbieta; Walczak, Maciej; Krawiec, Arkadiusz

    2013-01-01

    The present study was aimed at investigating the coexistence and interactions between free living amoebae of Naegleria and Hartmannella genera and pathogenic Legionella pneumophila bacteria in thermal saline baths used in balneotherapy in central Poland. Water samples were collected from November 2010 to May 2011 at intervals longer than 1 month. The microorganisms were detected with the use of a very sensitive fluorescence in situ hybridisation method. In addition, the morphology of the amoebae was studied. Despite relatively high salinity level, ranging from 1.5 to 5.0 %, L. pneumophila were found in all investigated baths, although their number never exceeded 10(6) cells dm(-3). Hartmannella were not detected, while Naegleria fowleri were found in one bath. The observation that N. fowleri and L. pneumophila may coexist in thermal saline baths is the first observation emphasising potential threat from these microorganisms in balneotherapy.

  7. Inhibition of host cell translation elongation by Legionella pneumophila blocks the host cell unfolded protein response.

    Science.gov (United States)

    Hempstead, Andrew D; Isberg, Ralph R

    2015-12-08

    Cells of the innate immune system recognize bacterial pathogens by detecting common microbial patterns as well as pathogen-specific activities. One system that responds to these stimuli is the IRE1 branch of the unfolded protein response (UPR), a sensor of endoplasmic reticulum (ER) stress. Activation of IRE1, in the context of Toll-like receptor (TLR) signaling, induces strong proinflammatory cytokine induction. We show here that Legionella pneumophila, an intravacuolar pathogen that replicates in an ER-associated compartment, blocks activation of the IRE1 pathway despite presenting pathogen products that stimulate this response. L. pneumophila TLR ligands induced the splicing of mRNA encoding XBP1s, the main target of IRE1 activity. L. pneumophila was able to inhibit both chemical and bacterial induction of XBP1 splicing via bacterial translocated proteins that interfere with host protein translation. A strain lacking five translocated translation elongation inhibitors was unable to block XBP1 splicing, but this could be rescued by expression of a single such inhibitor, consistent with limitation of the response by translation elongation inhibitors. Chemical inhibition of translation elongation blocked pattern recognition receptor-mediated XBP1 splicing, mimicking the effects of the bacterial translation inhibitors. In contrast, host cell-promoted inhibition of translation initiation in response to the pathogen was ineffective in blocking XBP1 splicing, demonstrating the need for the elongation inhibitors for protection from the UPR. The inhibition of host translation elongation may be a common strategy used by pathogens to limit the innate immune response by interfering with signaling via the UPR.

  8. Gentamicin-Containing Peptone-Yeast Extract Medium for Cocultivation of Hartmannella vermiformis ATCC 50256 and Virulent Strains of Legionella pneumophila.

    Science.gov (United States)

    Wadowsky, R M; Wang, L; Laus, S; Dowling, J N; Kuchta, J M; States, S J; Yee, R B

    1995-12-01

    We evaluated the use of peptone-yeast extract (PY) medium, different strains of Hartmannella vermiformis, and gentamicin in a coculture system to improve the discrimination of virulent and avirulent strains of Legionella pneumophila. H. vermiformis ATCC 50256 was unique among four strains of H. vermiformis, in that it multiplied equally well in Medium 1034 and PY medium (Medium 1034 without fetal calf serum, folic acid, hemin, and yeast nucleic acid and with a 50% reduction of peptone). However, both a virulent strain of L. pneumophila and its avirulent derivative strain multiplied in cocultures when PY medium was used. The multiplication of this avirulent strain was greatly reduced by incorporating gentamicin (1 (mu)g/ml) into the cocultivation system. Five virulent-avirulent sets of L. pneumophila strains were then tested for multiplication in cocultures with H. vermiformis ATCC 50256 and the gentamicin-containing PY medium. Only the virulent strains multiplied. The modified cocultivation system can discriminate between virulent and avirulent strains of L. pneumophila.

  9. Crystallization and preliminary crystallographic analysis of an aminoglycoside kinase from Legionella pneumophila

    International Nuclear Information System (INIS)

    Lemke, Christopher T.; Hwang, Jiyoung; Xiong, Bing; Cianciotto, Nicholas P.; Berghuis, Albert M.

    2005-01-01

    Two crystal forms of the antibiotic resistance enzyme APH(9)-Ia from L. pneumophila are reported. 9-Aminoglycoside phosphotransferase type Ia [APH(9)-Ia] is a resistance factor in Legionella pneuemophila, the causative agent of legionnaires’ disease. It is responsible for providing intrinsic resistance to the antibiotic spectinomycin. APH(9)-Ia phosphorylates one of the hydroxyl moieties of spectinomycin in an ATP-dependent manner, abolishing the antibiotic properties of this drug. Here, the crystallization and preliminary X-ray studies of this enzyme in two crystal forms is reported. One of the these crystal forms provides diffraction data to a resolution of 1.7 Å

  10. Neutrophil and Alveolar Macrophage-Mediated Innate Immune Control of Legionella pneumophila Lung Infection via TNF and ROS.

    Directory of Open Access Journals (Sweden)

    Pascal Ziltener

    2016-04-01

    Full Text Available Legionella pneumophila is a facultative intracellular bacterium that lives in aquatic environments where it parasitizes amoeba. However, upon inhalation of contaminated aerosols it can infect and replicate in human alveolar macrophages, which can result in Legionnaires' disease, a severe form of pneumonia. Upon experimental airway infection of mice, L. pneumophila is rapidly controlled by innate immune mechanisms. Here we identified, on a cell-type specific level, the key innate effector functions responsible for rapid control of infection. In addition to the well-characterized NLRC4-NAIP5 flagellin recognition pathway, tumor necrosis factor (TNF and reactive oxygen species (ROS are also essential for effective innate immune control of L. pneumophila. While ROS are essential for the bactericidal activity of neutrophils, alveolar macrophages (AM rely on neutrophil and monocyte-derived TNF signaling via TNFR1 to restrict bacterial replication. This TNF-mediated antibacterial mechanism depends on the acidification of lysosomes and their fusion with L. pneumophila containing vacuoles (LCVs, as well as caspases with a minor contribution from cysteine-type cathepsins or calpains, and is independent of NLRC4, caspase-1, caspase-11 and NOX2. This study highlights the differential utilization of innate effector pathways to curtail intracellular bacterial replication in specific host cells upon L. pneumophila airway infection.

  11. Close genetic relationship between Legionella pneumophila serogroup 1 isolates from sputum specimens and puddles on roads, as determined by sequence-based typing.

    Science.gov (United States)

    Kanatani, Jun-ichi; Isobe, Junko; Kimata, Keiko; Shima, Tomoko; Shimizu, Miwako; Kura, Fumiaki; Sata, Tetsutaro; Watahiki, Masanori

    2013-07-01

    We investigated the prevalence of Legionella species isolated from puddles on asphalt roads. In addition, we carried out sequence-based typing (SBT) analysis on the genetic relationship between L. pneumophila serogroup 1 (SG 1) isolates from puddles and from stock strains previously obtained from sputum specimens and public baths. Sixty-nine water samples were collected from puddles on roads at 6 fixed locations. Legionella species were detected in 33 samples (47.8%) regardless of season. Among the 325 isolates from puddles, strains of L. pneumophila SG 1, a major causative agent of Legionnaires' disease, were the most frequently isolated (n = 62, 19.1%). Sixty-two isolates of L. pneumophila SG 1 from puddles were classified into 36 sequence types (STs) by SBT. ST120 and ST48 were identified as major STs. Environmental ST120 strains from puddles were found for the first time in this study. Among the 14 STs of the clinical isolates (n = 19), 4 STs (n = 6, 31.6%), including ST120, were also detected in isolates from puddles on roads, and the sources of infection in these cases remained unclear. The lag-1 gene, a tentative marker for clinical isolates, was prevalent in puddle isolates (61.3%). Our findings suggest that puddles on asphalt roads serve as potential reservoirs for L. pneumophila in the environment.

  12. A new oligonucleotide microarray for detection of pathogenic and non-pathogenic Legionella spp.

    Directory of Open Access Journals (Sweden)

    Boyang Cao

    Full Text Available Legionella pneumophila has been recognized as the major cause of legionellosis since the discovery of the deadly disease. Legionella spp. other than L. pneumophila were later found to be responsible to many non-pneumophila infections. The non-L. pneumophila infections are likely under-detected because of a lack of effective diagnosis. In this report, we have sequenced the 16S-23S rRNA gene internal transcribed spacer (ITS of 10 Legionella species and subspecies, including L. anisa, L. bozemanii, L. dumoffii, L. fairfieldensis, L. gormanii, L. jordanis, L. maceachernii, L. micdadei, L. pneumophila subspp. fraseri and L. pneumophila subspp. pasculleii, and developed a rapid oligonucleotide microarray detection technique accordingly to identify 12 most common Legionella spp., which consist of 11 pathogenic species of L. anisa, L. bozemanii, L. dumoffii, L. gormanii, L. jordanis, L. longbeachae, L. maceachernii, L. micdadei, and L. pneumophila (including subspp. pneumophila, subspp. fraseri, and subspp. pasculleii and one non-pathogenic species, L. fairfieldensis. Twenty-nine probes that reproducibly detected multiple Legionella species with high specificity were included in the array. A total of 52 strains, including 30 target pathogens and 22 non-target bacteria, were used to verify the oligonucleotide microarray assay. The sensitivity of the detection was at 1.0 ng with genomic DNA or 13 CFU/100 mL with Legionella cultures. The microarray detected seven samples of air conditioner-condensed water with 100% accuracy, validating the technique as a promising method for applications in basic microbiology, clinical diagnosis, food safety, and epidemiological surveillance. The phylogenetic study based on the ITS has also revealed that the non-pathogenic L. fairfieldensis is the closest to L. pneumophila than the nine other pathogenic Legionella spp.

  13. A New Oligonucleotide Microarray for Detection of Pathogenic and Non-Pathogenic Legionella spp.

    Science.gov (United States)

    Cao, Boyang; Liu, Xiangqian; Yu, Xiang; Chen, Min; Feng, Lu; Wang, Lei

    2014-01-01

    Legionella pneumophila has been recognized as the major cause of legionellosis since the discovery of the deadly disease. Legionella spp. other than L. pneumophila were later found to be responsible to many non-pneumophila infections. The non-L. pneumophila infections are likely under-detected because of a lack of effective diagnosis. In this report, we have sequenced the 16S-23S rRNA gene internal transcribed spacer (ITS) of 10 Legionella species and subspecies, including L. anisa, L. bozemanii, L. dumoffii, L. fairfieldensis, L. gormanii, L. jordanis, L. maceachernii, L. micdadei, L. pneumophila subspp. fraseri and L. pneumophila subspp. pasculleii, and developed a rapid oligonucleotide microarray detection technique accordingly to identify 12 most common Legionella spp., which consist of 11 pathogenic species of L. anisa, L. bozemanii, L. dumoffii, L. gormanii, L. jordanis, L. longbeachae, L. maceachernii, L. micdadei, and L. pneumophila (including subspp. pneumophila, subspp. fraseri, and subspp. pasculleii) and one non-pathogenic species, L. fairfieldensis. Twenty-nine probes that reproducibly detected multiple Legionella species with high specificity were included in the array. A total of 52 strains, including 30 target pathogens and 22 non-target bacteria, were used to verify the oligonucleotide microarray assay. The sensitivity of the detection was at 1.0 ng with genomic DNA or 13 CFU/100 mL with Legionella cultures. The microarray detected seven samples of air conditioner-condensed water with 100% accuracy, validating the technique as a promising method for applications in basic microbiology, clinical diagnosis, food safety, and epidemiological surveillance. The phylogenetic study based on the ITS has also revealed that the non-pathogenic L. fairfieldensis is the closest to L. pneumophila than the nine other pathogenic Legionella spp. PMID:25469776

  14. Brote epidémico de neumonías por Legionella pneumophila en niños cubanos

    Directory of Open Access Journals (Sweden)

    Roberto Razón Behar

    2002-09-01

    Full Text Available La Legionella pneumophila es uno de los patógenos responsable de neumonías atípicas, a través de la inhalación de aerosoles o aspiración de líquidos infectados. Se detectó un brote epidémico de neumonías por Legionella, originado por la aspiración de agua contaminada de una piscina en un grupo de niños cubanos. El agente causal se identificó en 5 de 9 pacientes, por la técnica de inmunofluorescencia indirecta en muestras de sueros pareados. Los síntomas y signos más frecuentes fueron malestar general, anorexia, astenia, fiebre persistente de 39 °C a 40 °C (103 °F a 105 °F, mialgias, cefaleas, náuseas, vómitos, dolor abdominal, diarreas, tos húmeda, dolor torácico y polipnea. Durante el desarrollo de la enfermedad, el tratamiento antibiótico fue empírico (incluyendo los macrólidos, por no tener confirmado el diagnóstico. Todos los pacientes evolucionaron satisfactoriamente. Se reportó un brote epidémico de neumonías por Legionella en niños por primera vez en Cuba, lo cual tiene importancia clínica y epidemiológica.The legionella pneumophila is one of the pathogens responsible for atypic pneumonias by the inhalation of aerosols or aspiration of infected liquids. An epidemic outbreak of pneumonias caused by Legionella was detected among a group of Cuban children. It was originated by the aspiration of contaminated water in a swimming pool. The causal agent was identified in 5 of 9 patients by using the indirect immunofluorescence technique in samples of matched sera. The most frequent symptoms and signs were malaise, anorexia, asthenia, persistent fever from 39°C to 40°C (103° F to 105° F, myalgias, headache, nauseas, vomits, abdominal pain, diarrheas, moist cough, thoracic pain and polypnoea. The antibiotic treatment was empiric (including the macrolides during the development of the disease, since the diagnosis was not confirmed. The patients’ evolution was satisfactory. An epidemic outbreak of pneumonias

  15. [Diversity of Legionella pneumophila in cooling towers: coculture kinetics and virulence studies].

    Science.gov (United States)

    Ragull, Sonia; García-Núñez, Marian; Pedro-Botet, María Luisa; Rey-Joly, Celestino; Sabria, Miquel

    2011-05-01

    Legionella pneumophila (L. pneumophila) was isolated from three cooling towers involved in three community outbreaks of Legionnaireś disease. Each cooling tower had two different chromosomal DNA subtypes. However, only one matched identically to the clinical strains. To try to understand why only one of the environmental strains caused clinical cases we investigated the intrinsic virulence of these strains. We selected six strains of L. pneumophila sg.1: two strains (A1 and B1) from cooling tower 1, two strains (A2 and B2) from tower 2 and two strains (A3 and B3) from tower 3. One of the two subtypes (A) exhibited the same chromosomal DNA subtype as the strains isolated from the patients in each outbreak and the other exhibited a different subtype. The replication within macrophages, the presence of lipopolysaccharide epitope recognized by MAb 3/1 and the growth kinetics in BCYE broth were investigated. Isolates were typed by pulsed field electrophoresis. The A strains did not have a higher virulence level, but were able to grow and survive better than strains B in BCYE broth. These results suggest that the strains better adapted to the environment will manage to displace the others and will be able to spread and infect humans. The adaptation to the environmental conditions could play an important role in the pathogenesis of the strains. Copyright © 2010 Elsevier España, S.L. All rights reserved.

  16. Transcriptional down-regulation and rRNA cleavage in Dictyostelium discoideum mitochondria during Legionella pneumophila infection.

    Directory of Open Access Journals (Sweden)

    Chenyu Zhang

    2009-05-01

    Full Text Available Bacterial pathogens employ a variety of survival strategies when they invade eukaryotic cells. The amoeba Dictyostelium discoideum is used as a model host to study the pathogenic mechanisms that Legionella pneumophila, the causative agent of Legionnaire's disease, uses to kill eukaryotic cells. Here we show that the infection of D. discoideum by L. pneumophila results in a decrease in mitochondrial messenger RNAs, beginning more than 8 hours prior to detectable host cell death. These changes can be mimicked by hydrogen peroxide treatment, but not by other cytotoxic agents. The mitochondrial large subunit ribosomal RNA (LSU rRNA is also cleaved at three specific sites during the course of infection. Two LSU rRNA fragments appear first, followed by smaller fragments produced by additional cleavage events. The initial LSU rRNA cleavage site is predicted to be on the surface of the large subunit of the mitochondrial ribosome, while two secondary sites map to the predicted interface with the small subunit. No LSU rRNA cleavage was observed after exposure of D. discoideum to hydrogen peroxide, or other cytotoxic chemicals that kill cells in a variety of ways. Functional L. pneumophila type II and type IV secretion systems are required for the cleavage, establishing a correlation between the pathogenesis of L. pneumophila and D. discoideum LSU rRNA destruction. LSU rRNA cleavage was not observed in L. pneumophila infections of Acanthamoeba castellanii or human U937 cells, suggesting that L. pneumophila uses distinct mechanisms to interrupt metabolism in different hosts. Thus, L. pneumophila infection of D. discoideum results in dramatic decrease of mitochondrial RNAs, and in the specific cleavage of mitochondrial rRNA. The predicted location of the cleavage sites on the mitochondrial ribosome suggests that rRNA destruction is initiated by a specific sequence of events. These findings suggest that L. pneumophila specifically disrupts mitochondrial

  17. DupA: a key regulator of the amoebal MAP kinase response to Legionella pneumophila

    Science.gov (United States)

    Li, Zhiru; Dugan, Aisling S.; Bloomfield, Gareth; Skelton, Jason; Ivens, Alasdair; Losick, Vicki; Isberg, Ralph R.

    2009-01-01

    SUMMARY The dupA gene, encoding a putative tyrosine kinase/dual specificity phosphatase (Dusp), was identified in a screen for Dictyostelium discoideum mutants altered in supporting Legionella pneumophila intracellular replication. The absence of dupA resulted in hyperphosphorylation of ERK1, consistent with the loss of a phosphatase activity, as well as degradation of ERK2. ERK1 hyperphosphorylation mimicked the response of this protein after bacterial challenge of wild type amoebae. Similar to Dusps in higher eukaryotic cells, the amoebal dupA gene was induced after bacterial contact, indicating a response of Dusps that is conserved from amoebae to mammals. A large set of genes was misregulated in the dupA− mutant that largely overlaps with genes responding to L. pneumophila infection. Some of the amoebal genes appear to be involved in a response similar to innate immunity in higher eukaryotes, indicating there was misregulation of a conserved response to bacteria. PMID:19748467

  18. Prevalence of Legionella strains in cooling towers and legionellosis cases in New Zealand.

    Science.gov (United States)

    Lau, Robert; Maqsood, Saadia; Harte, David; Caughley, Brian; Deacon, Rob

    2013-01-01

    Over 3,900 water samples from 688 cooling towers were tested for Legionella in 2008 in New Zealand. Of 80 (2.05% isolation rate) Legionella isolates, 10 (12.5%) were L. pneumophila serogroup 1; 10 (12.5%) were L. anisa; nine (11.2%) were L. pneumophila serogroup 8; and one (1.2%) was L. longbeachae serogroup 2. Forty-one (51.2%) Legionella isolates were L. pneumophila serogroups. Over 3,990 water samples from 606 cooling towers were tested for Legionella in 2009 in New Zealand. Of 51 (1.28% isolation rate) Legionella isolates, 18 (35.3%) were L. pneumophila serogroup 1, and 39 (76.4%) were other L. pneumophila serogroups. L. pneumophila serogroups were significantly associated with legionellosis cases in 2008 and 2009. L. longbeachae serogroups were equally significantly associated with legionellosis cases. This significant association of L. longbeachae with legionellosis particularly of L. longbeachae serogroup 1 is unique in that part of the world. The authors' study also showed that the aqueous environment of the cooling tower is not a natural habitat for pathogenic L. longbeachae. Regular monitoring and maintenance of cooling towers have prevented outbreaks of legionellosis.

  19. Contamination of Tap Water with Pseudomonas aeruginosa, Legionella pneumophila, and Escherichia coli in Guilan, Iran

    Directory of Open Access Journals (Sweden)

    Masoumeh Ahmadi Jalali Moghadam

    2016-12-01

    Full Text Available Background: River and underground waters are main sources of tap water in Guilan, Iran. Overlandwastes move into rivers during periods of heavy or extended rain that is very common in the area.Pseudomonas aeruginosa, Legionella pneumophila, and Escherichia coli are main human pathogenswith water source. This study is designed to determine the load of these bacteria in main water suppliesof the area.Methods: Samples were collected directly into sterile containers, concentrated by centrifuge,inoculated in enrichment medium and incubated for 3-4 days. DNA was extracted by using commercialkit. Several rounds of PCR was performed to search P. aeroginosa, integron I, Metallo-β-lactamasesgene, L. pneumophila, mip gene, and E. coli.Results: About 92.0% of the samples showed bacterial contamination as revealed by PCR with primersof 16S rRNAgene, 9.5% of the samples had L. pneumophila, and 11,1% had Pseudomonas aeruginosa,but Escherichia coli was not detected. We found the mip gene in 66.6% of the samples with L.pneumophila. Metallo-β-lactamasesgene was found in 11.1% of all samples. We also found Integrin 1in 28.5% of the samples with P. aeruginosa.Conclusion: This study indicates that in spite of chlorination, total bacterial contamination of potwaters in the area is high and contamination with L. pneumophila and P. aeroginosa is considerable. Itmight be related to the biofilm formation and the growth of water microflora. It seems that free residualchlorine is ineffective. We suggest a more effective decontamination procedure based on moderntechnology.

  20. Role of biofilm roughness and hydrodynamic conditions in Legionella pneumophila adhesion to and detachment from simulated drinking water biofilms.

    Science.gov (United States)

    Shen, Yun; Monroy, Guillermo L; Derlon, Nicolas; Janjaroen, Dao; Huang, Conghui; Morgenroth, Eberhard; Boppart, Stephen A; Ashbolt, Nicholas J; Liu, Wen-Tso; Nguyen, Thanh H

    2015-04-07

    Biofilms in drinking water distribution systems (DWDS) could exacerbate the persistence and associated risks of pathogenic Legionella pneumophila (L. pneumophila), thus raising human health concerns. However, mechanisms controlling adhesion and subsequent detachment of L. pneumophila associated with biofilms remain unclear. We determined the connection between L. pneumophila adhesion and subsequent detachment with biofilm physical structure characterization using optical coherence tomography (OCT) imaging technique. Analysis of the OCT images of multispecies biofilms grown under low nutrient condition up to 34 weeks revealed the lack of biofilm deformation even when these biofilms were exposed to flow velocity of 0.7 m/s, typical flow for DWDS. L. pneumophila adhesion on these biofilm under low flow velocity (0.007 m/s) positively correlated with biofilm roughness due to enlarged biofilm surface area and local flow conditions created by roughness asperities. The preadhered L. pneumophila on selected rough and smooth biofilms were found to detach when these biofilms were subjected to higher flow velocity. At the flow velocity of 0.1 and 0.3 m/s, the ratio of detached cell from the smooth biofilm surface was from 1.3 to 1.4 times higher than that from the rough biofilm surface, presumably because of the low shear stress zones near roughness asperities. This study determined that physical structure and local hydrodynamics control L. pneumophila adhesion to and detachment from simulated drinking water biofilm, thus it is the first step toward reducing the risk of L. pneumophila exposure and subsequent infections.

  1. Growth-supporting activity for Legionella pneumophila in tap water cultures and implication of hartmannellid amoebae as growth factors.

    Science.gov (United States)

    Wadowsky, R M; Butler, L J; Cook, M K; Verma, S M; Paul, M A; Fields, B S; Keleti, G; Sykora, J L; Yee, R B

    1988-11-01

    Photosynthetic cyanobacteria, heterotrophic bacteria, free-living amoebae, and ciliated protozoa may support growth of Legionella pneumophila. Studies were done with two tap water cultures (WS1 and WS2) containing L. pneumophila and associated microbiota to characterize growth-supporting activity and assess the relative importance of the microbiota in supporting multiplication of L. pneumophila. The water cultures were incubated in the dark at 35 degrees C. The growth-supporting factor(s) was separated from each culture by filtration through 1-micron-pore-size membrane filters. The retentate was then suspended in sterile tap water. Multiplication of L. pneumophila occurred when both the retentate suspension and the filtrate from either culture were inoculated into sterile tap water. L. pneumophila did not multiply in tap water inoculated with only the filtrate, even though filtration did not reduce the concentration of L. pneumophila or heterotrophic bacteria in either culture. Growth-supporting activity of the retentate suspension from WS1 was inactivated at 60 degrees C but unaffected at 0, 25, and 45 degrees C after 30-min incubations. Filtration experiments indicated that the growth-supporting factor(s) in WS1 was 2 to 5 micron in diameter. Ciliated protozoa were not detected in either culture. Hartmannellid amoebae were conclusively demonstrated in WS2 but not in WS1. L. pneumophila multiplied in tap water inoculated with the amoebae (10(3)/ml) and the 1-micron filtrate of WS2. No multiplication occurred in tap water inoculated with the filtrate only. Growth-supporting activity for L. pneumophila may be present in plumbing systems; hartmannellid amoebae appear to be important determinants of multiplication of L. pneumophila in some tap water cultures.

  2. Virulence factor rtx in Legionella pneumophila, evidence suggesting it is a modular multifunctional protein

    Directory of Open Access Journals (Sweden)

    Pelaz Carmen

    2008-01-01

    Full Text Available Abstract Background The repeats in toxin (Rtx are an important pathogenicity factor involved in host cells invasion of Legionella pneumophila and other pathogenic bacteria. Its role in escaping the host immune system and cytotoxic activity is well known. Its repeated motives and modularity make Rtx a multifunctional factor in pathogenicity. Results The comparative analysis of rtx gene among 6 strains of L. pneumophila showed modularity in their structures. Among compared genomes, the N-terminal region of the protein presents highly dissimilar repeats with functionally similar domains. On the contrary, the C-terminal region is maintained with a fashionable modular configuration, which gives support to its proposed role in adhesion and pore formation. Despite the variability of rtx among the considered strains, the flanking genes are maintained in synteny and similarity. Conclusion In contrast to the extracellular bacteria Vibrio cholerae, in which the rtx gene is highly conserved and flanking genes have lost synteny and similarity, the gene region coding for the Rtx toxin in the intracellular pathogen L. pneumophila shows a rapid evolution. Changes in the rtx could play a role in pathogenicity. The interplay of the Rtx toxin with host membranes might lead to the evolution of new variants that are able to escape host cell defences.

  3. Phenylalanine hydroxylase from Legionella pneumophila is a thermostable enzyme with a major functional role in pyomelanin synthesis.

    Directory of Open Access Journals (Sweden)

    Marte I Flydal

    Full Text Available Legionella pneumophila is a pathogenic bacterium that can cause Legionnaires' disease and other non-pneumonic infections in humans. This bacterium produces a pyomelanin pigment, a potential virulence factor with ferric reductase activity. In this work, we have investigated the role of phenylalanine hydroxylase from L. pneumophila (lpPAH, the product of the phhA gene, in the synthesis of the pyomelanin pigment and the growth of the bacterium in defined compositions.Comparative studies of wild-type and phhA mutant corroborate that lpPAH provides the excess tyrosine for pigment synthesis. phhA and letA (gacA appear transcriptionally linked when bacteria were grown in buffered yeast extract medium at 37°C. phhA is expressed in L. pneumophila growing in macrophages. We also cloned and characterized lpPAH, which showed many characteristics of other PAHs studied so far, including Fe(II requirement for activity. However, it also showed many particular properties such as dimerization, a high conformational thermal stability, with a midpoint denaturation temperature (T(m = 79 ± 0.5°C, a high specific activity at 37°C (10.2 ± 0.3 µmol L-Tyr/mg/min and low affinity for the substrate (K(m (L-Phe = 735 ± 50 µM.lpPAH has a major functional role in the synthesis of pyomelanin and promotes growth in low-tyrosine media. The high thermal stability of lpPAH might reflect the adaptation of the enzyme to withstand relatively high survival temperatures.

  4. Legionella contamination in hot water of Italian hotels.

    Science.gov (United States)

    Borella, Paola; Montagna, Maria Teresa; Stampi, Serena; Stancanelli, Giovanna; Romano-Spica, Vincenzo; Triassi, Maria; Marchesi, Isabella; Bargellini, Annalisa; Tatò, Daniela; Napoli, Christian; Zanetti, Franca; Leoni, Erica; Moro, Matteo; Scaltriti, Stefania; Ribera D'Alcalà, Gabriella; Santarpia, Rosalba; Boccia, Stefania

    2005-10-01

    A cross-sectional multicenter survey of Italian hotels was conducted to investigate Legionella spp. contamination of hot water. Chemical parameters (hardness, free chlorine concentration, and trace element concentrations), water systems, and building characteristics were evaluated to study risk factors for colonization. The hot water systems of Italian hotels were strongly colonized by Legionella; 75% of the buildings examined and 60% of the water samples were contaminated, mainly at levels of > or =10(3) CFU liter(-1), and Legionella pneumophila was the most frequently isolated species (87%). L. pneumophila serogroup 1 was isolated from 45.8% of the contaminated sites and from 32.5% of the hotels examined. When a multivariate logistic model was used, only hotel age was associated with contamination, but the risk factors differed depending on the contaminating species and serogroup. Soft water with higher chlorine levels and higher temperatures were associated with L. pneumophila serogroup 1 colonization, whereas the opposite was observed for serogroups 2 to 14. In conclusion, Italian hotels, particularly those located in old buildings, represent a major source of risk for Legionnaires' disease due to the high frequency of Legionella contamination, high germ concentration, and major L. pneumophila serogroup 1 colonization. The possible role of chlorine in favoring the survival of Legionella species is discussed.

  5. SPR based immunosensor for detection of Legionella pneumophila in water samples

    Science.gov (United States)

    Enrico, De Lorenzis; Manera, Maria G.; Montagna, Giovanni; Cimaglia, Fabio; Chiesa, Maurizio; Poltronieri, Palmiro; Santino, Angelo; Rella, Roberto

    2013-05-01

    Detection of legionellae by water sampling is an important factor in epidemiological investigations of Legionnaires' disease and its prevention. To avoid labor-intensive problems with conventional methods, an alternative, highly sensitive and simple method is proposed for detecting L. pneumophila in aqueous samples. A compact Surface Plasmon Resonance (SPR) instrumentation prototype, provided with proper microfluidics tools, is built. The developed immunosensor is capable of dynamically following the binding between antigens and the corresponding antibody molecules immobilized on the SPR sensor surface. A proper immobilization strategy is used in this work that makes use of an important efficient step aimed at the orientation of antibodies onto the sensor surface. The feasibility of the integration of SPR-based biosensing setups with microfluidic technologies, resulting in a low-cost and portable biosensor is demonstrated.

  6. Diverse mechanisms of metaeffector activity in an intracellular bacterial pathogen, Legionella pneumophila.

    Science.gov (United States)

    Urbanus, Malene L; Quaile, Andrew T; Stogios, Peter J; Morar, Mariya; Rao, Chitong; Di Leo, Rosa; Evdokimova, Elena; Lam, Mandy; Oatway, Christina; Cuff, Marianne E; Osipiuk, Jerzy; Michalska, Karolina; Nocek, Boguslaw P; Taipale, Mikko; Savchenko, Alexei; Ensminger, Alexander W

    2016-12-16

    Pathogens deliver complex arsenals of translocated effector proteins to host cells during infection, but the extent to which these proteins are regulated once inside the eukaryotic cell remains poorly defined. Among all bacterial pathogens, Legionella pneumophila maintains the largest known set of translocated substrates, delivering over 300 proteins to the host cell via its Type IVB, Icm/Dot translocation system. Backed by a few notable examples of effector-effector regulation in L. pneumophila, we sought to define the extent of this phenomenon through a systematic analysis of effector-effector functional interaction. We used Saccharomyces cerevisiae, an established proxy for the eukaryotic host, to query > 108,000 pairwise genetic interactions between two compatible expression libraries of ~330 L. pneumophila-translocated substrates. While capturing all known examples of effector-effector suppression, we identify fourteen novel translocated substrates that suppress the activity of other bacterial effectors and one pair with synergistic activities. In at least nine instances, this regulation is direct-a hallmark of an emerging class of proteins called metaeffectors, or "effectors of effectors". Through detailed structural and functional analysis, we show that metaeffector activity derives from a diverse range of mechanisms, shapes evolution, and can be used to reveal important aspects of each cognate effector's function. Metaeffectors, along with other, indirect, forms of effector-effector modulation, may be a common feature of many intracellular pathogens-with unrealized potential to inform our understanding of how pathogens regulate their interactions with the host cell. © 2016 The Authors. Published under the terms of the CC BY 4.0 license.

  7. Legionella risk assessment in cruise ships and ferries

    Directory of Open Access Journals (Sweden)

    Pasqualina Laganà

    2017-06-01

    Legionella pneumophila sg 1 was isolated from the samples of shower and tap water in 7 (70% of the 10 ferries examined, and in 3 (33% of the 6 cruise ships examined, and L. pneumophila sg 2–14 in 8 (80% and 1 (16.7% of these ships, respectively. No Legionella contamination was found in whirlpool baths, air and ice samples. In conclusion, the data obtained confirm higher levels of Legionella contamination in local ferries and cruise ships, underlining the need to adopt corrective actions more specific for these smaller vessels.

  8. Diverse protist grazers select for virulence-related traits in Legionella

    Science.gov (United States)

    Amaro, Francisco; Wang, Wen; Gilbert, Jack A; Roger Anderson, O; Shuman, Howard A

    2015-01-01

    It is generally accepted that selection for resistance to grazing by protists has contributed to the evolution of Legionella pneumophila as a pathogen. Grazing resistance is becoming more generally recognized as having an important role in the ecology and evolution of bacterial pathogenesis. However, selection for grazing resistance presupposes the existence of protist grazers that provide the selective pressure. To determine whether there are protists that graze on pathogenic Legionella species, we investigated the existence of such organisms in a variety of environmental samples. We isolated and characterized diverse protists that graze on L. pneumophila and determined the effects of adding L. pneumophila on the protist community structures in microcosms made from these environmental samples. Several unrelated organisms were able to graze efficiently on L. pneumophila. The community structures of all samples were markedly altered by the addition of L. pneumophila. Surprisingly, some of the Legionella grazers were closely related to species that are known hosts for L. pneumophila, indicating the presence of unknown specificity determinants for this interaction. These results provide the first direct support for the hypothesis that protist grazers exert selective pressure on Legionella to acquire and retain adaptations that contribute to survival, and that these properties are relevant to the ability of the bacteria to cause disease in people. We also report a novel mechanism of killing of amoebae by one Legionella species that requires an intact Type IV secretion system but does not involve intracellular replication. We refer to this phenomenon as ‘food poisoning'. PMID:25575308

  9. Distribution of sequence-based types of legionella pneumophila serogroup 1 strains isolated from cooling towers, hot springs, and potable water systems in China.

    Science.gov (United States)

    Qin, Tian; Zhou, Haijian; Ren, Hongyu; Guan, Hong; Li, Machao; Zhu, Bingqing; Shao, Zhujun

    2014-04-01

    Legionella pneumophila serogroup 1 causes Legionnaires' disease. Water systems contaminated with Legionella are the implicated sources of Legionnaires' disease. This study analyzed L. pneumophila serogroup 1 strains in China using sequence-based typing. Strains were isolated from cooling towers (n = 96), hot springs (n = 42), and potable water systems (n = 26). Isolates from cooling towers, hot springs, and potable water systems were divided into 25 sequence types (STs; index of discrimination [IOD], 0.711), 19 STs (IOD, 0.934), and 3 STs (IOD, 0.151), respectively. The genetic variation among the potable water isolates was lower than that among cooling tower and hot spring isolates. ST1 was the predominant type, accounting for 49.4% of analyzed strains (n = 81), followed by ST154. With the exception of two strains, all potable water isolates (92.3%) belonged to ST1. In contrast, 53.1% (51/96) and only 14.3% (6/42) of cooling tower and hot spring, respectively, isolates belonged to ST1. There were differences in the distributions of clone groups among the water sources. The comparisons among L. pneumophila strains isolated in China, Japan, and South Korea revealed that similar clones (ST1 complex and ST154 complex) exist in these countries. In conclusion, in China, STs had several unique allelic profiles, and ST1 was the most prevalent sequence type of environmental L. pneumophila serogroup 1 isolates, similar to its prevalence in Japan and South Korea.

  10. Atypical presentation of Legionella pneumonia among patients with underlying cancer: A fifteen-year review.

    Science.gov (United States)

    del Castillo, Maria; Lucca, Anabella; Plodkowski, Andrew; Huang, Yao-Ting; Kaplan, Janice; Gilhuley, Kathleen; Babady, N Esther; Seo, Susan K; Kamboj, Mini

    2016-01-01

    Immunocompromised patients, especially those receiving treatment with corticosteroids and cytotoxic chemotherapy are at increased risk for developing Legionella pneumonia. The aim of this study was to determine clinical and radiographic characteristics of pulmonary infection due to Legionella in persons undergoing treatment for cancer and stem cell transplant (SCT) recipients. Retrospective review of Legionella cases at MSKCC over a fifteen-year study period from January 1999 and December 2013. Cases were identified by review of microbiology records. During the study period, 40 cases of Legionella infection were identified; nine among these were due to non-pneumophila species. Most cases occurred during the summer. The majority [8/9, (89%)] of patients with non-pneumophila infection had underlying hematologic malignancy, compared to 18/31 (58%) with Legionella pneumophila infections. Radiographic findings were varied-nodular infiltrates mimicking invasive fungal infection were seen only among patients with hematologic malignancy and hematopoietic stem cell transplant (SCT) recipients and were frequently associated with non-pneumophila infections (50% vs 16%; P = 0.0594). All cases of nodular Legionella pneumonia were found incidentally or had an indolent clinical course. Legionella should be considered in the differential diagnosis of nodular lung lesions in immunocompromised patients, especially those with hematologic malignancy and SCT recipients. Most cases of nodular disease due to Legionella are associated with non-pneumophila infections. Copyright © 2015 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  11. Molecular diagnosis of Legionella infections--Clinical utility of front-line screening as part of a pneumonia diagnostic algorithm.

    Science.gov (United States)

    Gadsby, Naomi J; Helgason, Kristjan O; Dickson, Elizabeth M; Mills, Jonathan M; Lindsay, Diane S J; Edwards, Giles F; Hanson, Mary F; Templeton, Kate E

    2016-02-01

    Urinary antigen testing for Legionella pneumophila serogroup 1 is the leading rapid diagnostic test for Legionnaires' Disease (LD); however other Legionella species and serogroups can also cause LD. The aim was to determine the utility of front-line L. pneumophila and Legionella species PCR in a severe respiratory infection algorithm. L. pneumophila and Legionella species duplex real-time PCR was carried out on 1944 specimens from hospitalised patients over a 4 year period in Edinburgh, UK. L. pneumophila was detected by PCR in 49 (2.7%) specimens from 36 patients. During a LD outbreak, combined L. pneumophila respiratory PCR and urinary antigen testing had optimal sensitivity and specificity (92.6% and 98.3% respectively) for the detection of confirmed cases. Legionella species was detected by PCR in 16 (0.9%) specimens from 10 patients. The 5 confirmed and 1 probable cases of Legionella longbeachae LD were both PCR and antibody positive. Front-line L. pneumophila and Legionella species PCR is a valuable addition to urinary antigen testing as part of a well-defined algorithm. Cases of LD due to L. longbeachae might be considered laboratory-confirmed when there is a positive Legionella species PCR result and detection of L. longbeachae specific antibody response. Copyright © 2015 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  12. Evaluation of the Gen-Probe DNA probe for the detection of legionellae in culture

    International Nuclear Information System (INIS)

    Edelstein, P.H.

    1986-01-01

    A commercial DNA probe kit designed to detect rRNA from legionellae was evaluated for its ability to correctly discriminate between legionellae and non-legionellae taken from culture plates. The probe kit, made by the Gen-Probe Corp. (San Diego, Calif.), was radiolabeled with 125 I, and probe bacterial RNA hybridization, detected in a simple one-tube system hybridization assay, was quantitated with a gamma counter. A total of 156 Legionella sp. strains were tested, of which 125 were Legionella pneumophila and the remainder were strains from 21 other Legionella spp. A total of 106 gram-negative non-legionellae, isolated from human respiratory tract (81%) and other body site (19%) specimens, were also tested; 14 genera and 28 species were represented. The probe easily distinguished all of the legionellae from the non-legionellae. The average legionellae/non-legionellae hybridization ratio was 42:1, and the lowest ratio was 2:1; a minor modification in the procedure increased the lowest ratio to 5:1. In addition to correctly identifying all Legionella species, the probe was able to separate some of the various species of Legionella. L. pneumophila strains hybridized more completely to the probe than did the other Legionella spp.; L. wadsworthii and L. oakridgensis hybridized only about 25% of the probe relative to L. pneumophila. Some strains of phenotypically identified L. pneumophila had much lower hybridization to the probe than other members of the species and may represent a new Legionella species. The simplicity of the technique and specificity of the probe make it a good candidate for confirming the identity of legionellae in culture

  13. Removal of bacteria Legionella pneumophila, Escherichia coli, and Bacillus subtilis by (super)cavitation.

    Science.gov (United States)

    Šarc, Andrej; Kosel, Janez; Stopar, David; Oder, Martina; Dular, Matevž

    2018-04-01

    In sufficient concentrations, the pathogenic bacteria L. pneumophila can cause a respiratory illness that is known as the "Legionnaires" disease. Moreover, toxic Shiga strains of bacteria E. coli can cause life-threatening hemolytic-uremic syndrome. Because of the recent restrictions imposed on the usage of chlorine, outbreaks of these two bacterial species have become more common. In this study we have developed a novel rotation generator and its effectiveness against bacteria Legionella pneumophila and Escherichia coli was tested for various types of hydrodynamic cavitation (attached steady cavitation, developed unsteady cavitation and supercavitation). The results show that the supercavitation was the only effective form of cavitation. It enabled more than 3 logs reductions for both bacterial species and was also effective against a more persistent Gram positive bacteria, B. subtilis. The deactivation mechanism is at present unknown. It is proposed that when bacterial cells enter a supercavitation cavity, an immediate pressure drop occurs and this results in bursting of the cellular membrane. The new rotation generator that induced supercavitation proved to be economically and microbiologically far more effective than the classical Venturi section (super)cavitation. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Biofilm Composition and Threshold Concentration for Growth of Legionella pneumophila on Surfaces Exposed to Flowing Warm Tap Water without Disinfectant.

    Science.gov (United States)

    van der Kooij, Dick; Bakker, Geo L; Italiaander, Ronald; Veenendaal, Harm R; Wullings, Bart A

    2017-03-01

    Legionella pneumophila in potable water installations poses a potential health risk, but quantitative information about its replication in biofilms in relation to water quality is scarce. Therefore, biofilm formation on the surfaces of glass and chlorinated polyvinyl chloride (CPVC) in contact with tap water at 34 to 39°C was investigated under controlled hydraulic conditions in a model system inoculated with biofilm-grown L. pneumophila The biofilm on glass (average steady-state concentration, 23 ± 9 pg ATP cm -2 ) exposed to treated aerobic groundwater (0.3 mg C liter -1 ; 1 μg assimilable organic carbon [AOC] liter -1 ) did not support growth of the organism, which also disappeared from the biofilm on CPVC (49 ± 9 pg ATP cm -2 ) after initial growth. L. pneumophila attained a level of 4.3 log CFU cm -2 in the biofilms on glass (1,055 ± 225 pg ATP cm -2 ) and CPVC (2,755 ± 460 pg ATP cm -2 ) exposed to treated anaerobic groundwater (7.9 mg C liter -1 ; 10 μg AOC liter -1 ). An elevated biofilm concentration and growth of L. pneumophila were also observed with tap water from the laboratory. The Betaproteobacteria Piscinibacter and Methyloversatilis and amoeba-resisting Alphaproteobacteria predominated in the clones and isolates retrieved from the biofilms. In the biofilms, the Legionella colony count correlated significantly with the total cell count (TCC), heterotrophic plate count, ATP concentration, and presence of Vermamoeba vermiformis This amoeba was rarely detected at biofilm concentrations of water-associated disease outbreaks reported in the United States. The organism proliferates in biofilms on surfaces exposed to warm water in engineered freshwater installations. An investigation with a test system supplied with different types of warm drinking water without disinfectant under controlled hydraulic conditions showed that treated aerobic groundwater (0.3 mg liter -1 of organic carbon) induced a low biofilm concentration that supported no or very

  15. Interaction of legionella pneumophila and helicobacter pylori with bacterial species isolated from drinking water biofilms

    Directory of Open Access Journals (Sweden)

    Azevedo Nuno F

    2011-03-01

    Full Text Available Abstract Background It is well established that Legionella pneumophila is a waterborne pathogen; by contrast, the mode of Helicobacter pylori transmission remains unknown but water seems to play an important role. This work aims to study the influence of five microorganisms isolated from drinking water biofilms on the survival and integration of both of these pathogens into biofilms. Results Firstly, both pathogens were studied for auto- and co-aggregation with the species isolated from drinking water; subsequently the formation of mono and dual-species biofilms by L. pneumophila or H. pylori with the same microorganisms was investigated. Neither auto- nor co-aggregation was observed between the microorganisms tested. For biofilm studies, sessile cells were quantified in terms of total cells by SYTO 9 staining, viable L. pneumophila or H. pylori cells were quantified using 16 S rRNA-specific peptide nucleic acid (PNA probes and cultivable cells by standard culture techniques. Acidovorax sp. and Sphingomonas sp. appeared to have an antagonistic effect on L. pneumophila cultivability but not on the viability (as assessed by rRNA content using the PNA probe, possibly leading to the formation of viable but noncultivable (VBNC cells, whereas Mycobacterium chelonae increased the cultivability of this pathogen. The results obtained for H. pylori showed that M. chelonae and Sphingomonas sp. help this pathogen to maintain cultivability for at least 24 hours. Conclusions It appears that M. chelonae may have an important role in the survival of both pathogens in drinking water. This work also suggests that the presence of some microorganisms can decrease the cultivability of L. pneumophila but not the viability which indicates that the presence of autochthonous microorganisms can lead to misleading results when the safety of water is assessed by cultivable methods alone.

  16. A comparison of assays measuring the viability of Legionella ...

    Science.gov (United States)

    Background: The relatively high prevalence of Legionella pneumophila in premise plumbing systems has been widely reported. Published reports indicate Legionella has a comparatively high resistance to chlorine and moreover has the ability to grow in phagocytic amoeba which could provide additional protection in chlorinated drinking water distribution systems. Copper-Silver (Cu-Ag) ionization treatment systems are commercially available for use in large building water systems to help control the risks from Legionella bacteria. The objectives of this study were to develop and optimize Legionella viability assays and use them to investigate the viability of Legionella bacteria after exposure to water treated with coppper and silver ions. Methods: Log phase L. pneumophila cells were used in all experiments and were generated by incubation at 35C for 48 hours in buffered yeast extract broth. Viability assays used included plating on buffered charcoal yeast extract agar to determine the number of culturable cells and treating cells with propidium monoazide (PMA) or ethidium monoazide (EMA) followed by quantitative PCR targeting mip gene of L. pneumophila. The qPCR viability assays were optimized using L. pneumophila inactivated by heat treatment at 65C for 60 min. The effectiveness of Cu-Ag ionization treatment was studied by inoculating L. pneumonia at 105 CFU/mL in water collected directly from a building water system that employed this technology and incubat

  17. [Legionella pneumonia after the use of CPAP equipment].

    Science.gov (United States)

    Stolk, Jaap M; Russcher, Anne; van Elzakker, Erika P M; Schippers, Emile F

    2016-01-01

    Continuous positive airway pressure (CPAP) equipment can be colonised by Legionellae and might cause Legionella pneumonia in the user. However, there is no reported case of Legionella pneumonia related to CPAP equipment in which an identical Legionella was found in both the patient and the CPAP equipment. A 51-year-old man came to the Emergency Department with fever, confusion and dyspnoea that had been present for 3 days. His medical history included obstructive sleep apnoea, for which he had been using CPAP therapy at home for 10 weeks. The CPAP equipment showed signs of poor maintenance. Chest X-ray revealed a pulmonary consolidation. Laboratory investigation resulted in a positive urine antigen test for Legionella. Water from the CPAP equipment and sputum from the patient revealed Legionella pneumophila. Serotyping and sequence-based typing showed an identical L. pneumophila serotype 1 ST37. It is important to be aware that CPAP equipment can be colonised with Legionellae and might cause Legionella pneumonia. It is therefore necessary to ask about CPAP therapy in a patient with community-acquired pneumonia.

  18. Survey of Legionella spp. in Mud Spring Recreation Area

    Science.gov (United States)

    Hsu, B.-M.; Ma, P.-H.; Su, I.-Z.; Chen, N.-S.

    2009-04-01

    Legionella genera are parasites of FLA, and intracellular bacterial replication within the FLA plays a major role in the transmission of disease. At least 13 FLA species—including Acanthamoeba spp., Naegleria spp., and Hartmannella spp.—support intracellular bacterial replication. In the study, Legionellae were detected with microbial culture or by direct DNA extraction and analysis from concentrated water samples or cultured free-living amoebae, combined with molecular methods that allow the taxonomic identification of these pathogens. The water samples were taken from a mud spring recreation area located in a mud-rock-formation area in southern Taiwan. Legionella were detected in 15 of the 34 samples (44.1%). Four of the 34 samples analyzed by Legionella culture were positive for Legionella, five of 34 were positive for Legionella when analyzed by direct DNA extraction and analysis, and 11 of 34 were positive for amoebae-resistant Legionella when analyzed by FLA culture. Ten samples were shown to be positive for Legionella by one analysis method and five samples were shown to be positive by two analysis methods. However, Legionella was detected in no sample by all three analysis methods. This suggests that the three analysis methods should be used together to detect Legionella in aquatic environments. In this study, L. pneumophila serotype 6 coexisted with A. polyphaga, and two uncultured Legionella spp. coexisted with either H. vermiformis or N. australiensis. Of the unnamed Legionella genotypes detected in six FLA culture samples, three were closely related to L. waltersii and the other three were closely related to L. pneumophila serotype 6. Legionella pneumophila serotype 6, L. drancourtii, and L. waltersii are noted endosymbionts of FLA and are categorized as pathogenic bacteria. This is significant for human health because these Legionella exist within FLA and thus come into contact with typically immunocompromised people.

  19. May car washing represent a risk for Legionella infection?

    Science.gov (United States)

    Baldovin, T; Pierobon, A; Bertoncello, C; Destefani, E; Gennari, M; Stano, A; Baldo, V

    2018-01-01

    Legionella is a ubiquitous Gram-negative bacterium naturally found in aquatic environments. It can pose a health problem when it grows and spreads in man-made water systems. Legionella pneumophila is the most common cause of Legionnaires' disease nowadays, a community-acquired pneumonia with pulmonary symptoms and chest radiography no different from any other form of infectious pneumonia. Legionella monitoring is important for public health reasons, including the identification of unusual environmental sources of Legionella. We report two cases of Legionnaires' disease associated with two different car wash installations in the province of Vicenza, in the Veneto region, northeastern Italy. Patients were not employees of the car wash installations, but users of the service. In both cases, Legionella antigen was detected in urine using the Alere BinaxNOW® Legionella Urinary Antigen, and Legionella antibodies were detected in serum using SERION ELISA classic Legionella pneumophila 1-7 IgG and IgM. Water samples were also analyzed as part of the surveillance program for Legionella prevention and control in compliance with the Italian guidelines. Both patients had clinical symptoms and chest radiography compatible with pneumonia, and only one of them had diabetes as a risk factor. Legionella urinary antigen and serological test on serum samples were positive for Legionella in both patients, even if much slighter in the case A due to the retrospective serological investigation performed a year later the episode and after the second clinical case occurred in the same district. The environmental investigations highlighted two different car wash plants as potential source of infection. A certified company using shock hyperchlorination was asked to disinfect the two plants and, subsequently, control samples resulted negative for Legionella pneumophila. Any water source producing aerosols should be considered at risk for the transmission of Legionella bacteria, including car

  20. Legionella safety in cooling towers; Legionellaveiligheid in koeltorens

    Energy Technology Data Exchange (ETDEWEB)

    Kordes, B. [Kordes Advies, (Netherlands); De Bok, F. [KBBL Wijhe, (Netherlands); De Zeeuw, L. [Holland Environment Group, (Netherlands); Settels, P. [Safety, Health Services and Ergonomics, ING, (Netherlands); Oesterholt, F.; Wullings, B. [KWR Watercycle Research Institute, (Netherlands); Guiot, P. [Tevan, Gorinchem (Netherlands); Brands, R. [Cumulus Nederland, Cuijk (Netherlands); Nuijten, O. [Kennisinstituut ISSO, Rotterdam (Netherlands); Wijne, R. [Beer advocaten, Amsterdam (Netherlands)

    2010-04-15

    In 9 articles attention is paid to several aspects with regard to Legionella in cooling towers: representative sampling, the use of copper and silver ionization or hydrogen peroxide to prevent Legionella growth and biofilms, the use of a zero-tolerance model to control a cooling tower installation, detection of DNA of Legionella Pneumophila, legionella safety in air conditioners, the model Legionella risk analysis and control of cooling tower installations, legislation and regulations for the control of cooling tower installations with regard to the Dutch Occupational Health and Safety Act ('Arbo-wet'), and an article about a lawsuit for victims of a Legionella outbreak, caused by careless owners of a cooling tower in Amsterdam, Netherlands. [Dutch] In 9 artikelen wordt in deze aflevering aandacht besteed aan verschillende aspecten m.b.t. Legionella in koeltorens: representatieve monstername, de toepassing van koper en zilver-ionisatie of waterstofperoxide om de groei van Legionella en biofilms te voorkomen, het gebruik van een zero-tolerance model om een koeltoren installatie te controleren, detectie van DNA van Legionella Pneumophila, Legionella veiligheid in luchtbehandelingsinstallaties, het model Legionella risicoanalyse en beheersplan voor koeltoreninstallaties, de rol van de Arbo-wet, en een artikel over een rechtszaak voor slachtoffers van Legionella door onzorgvuldig beheer van een koeltoren in Amsterdam.

  1. Phylogenetic reconstruction of the Legionella pneumophila Philadelphia-1 laboratory strains through comparative genomics.

    Directory of Open Access Journals (Sweden)

    Chitong Rao

    Full Text Available Over 20 years ago, two groups independently domesticated Legionella pneumophila from a clinical isolate of bacteria collected during the first recognized outbreak of Legionnaires' disease (at the 1976 American Legion's convention in Philadelphia. These two laboratory strains, JR32 and Lp01, along with their derivatives, have been disseminated to a number of laboratories around the world and form the cornerstone of much of the research conducted on this important pathogen to date. Nevertheless, no exhaustive examination of the genetic distance between these strains and their clinical progenitor has been performed thus far. Such information is of paramount importance for making sense of several phenotypic differences observed between these strains. As environmental replication of L. pneumophila is thought to exclusively occur within natural protozoan hosts, retrospective analysis of the domestication and axenic culture of the Philadelphia-1 progenitor strain by two independent groups also provides an excellent opportunity to uncover evidence of adaptation to the laboratory environment. To reconstruct the phylogenetic relationships between the common laboratory strains of L. pneumophila Philadelphia-1 and their clinical ancestor, we performed whole-genome Illumina resequencing of the two founders of each laboratory lineage: JR32 and Lp01. As expected from earlier, targeted studies, Lp01 and JR32 contain large deletions in the lvh and tra regions, respectively. By sequencing additional strains derived from Lp01 (Lp02 and Lp03, we retraced the phylogeny of these strains relative to their reported ancestor, thereby reconstructing the evolutionary dynamics of each laboratory lineage from genomic data.

  2. Genomic investigation of a suspected outbreak of legionella pneumophila st82 reveals undetected heterogeneity by the present gold-standard methods, denmark, july to november 2014

    DEFF Research Database (Denmark)

    Schjørring, Susanne; Stegger, M.; Kjelsø, C.

    2017-01-01

    Between July and November 2014, 15 communityacquired cases of Legionnaires’ disease (LD), including four with Legionella pneumophila serogroup 1 sequence type (ST) 82, were diagnosed in Northern Zealand, Denmark. An outbreak was suspected. No ST82 isolates were found in environmental samples and ...

  3. Evaluation of an Optimal Epidemiological Typing Scheme for Legionella pneumophila with Whole-Genome Sequence Data Using Validation Guidelines.

    Science.gov (United States)

    David, Sophia; Mentasti, Massimo; Tewolde, Rediat; Aslett, Martin; Harris, Simon R; Afshar, Baharak; Underwood, Anthony; Fry, Norman K; Parkhill, Julian; Harrison, Timothy G

    2016-08-01

    Sequence-based typing (SBT), analogous to multilocus sequence typing (MLST), is the current "gold standard" typing method for investigation of legionellosis outbreaks caused by Legionella pneumophila However, as common sequence types (STs) cause many infections, some investigations remain unresolved. In this study, various whole-genome sequencing (WGS)-based methods were evaluated according to published guidelines, including (i) a single nucleotide polymorphism (SNP)-based method, (ii) extended MLST using different numbers of genes, (iii) determination of gene presence or absence, and (iv) a kmer-based method. L. pneumophila serogroup 1 isolates (n = 106) from the standard "typing panel," previously used by the European Society for Clinical Microbiology Study Group on Legionella Infections (ESGLI), were tested together with another 229 isolates. Over 98% of isolates were considered typeable using the SNP- and kmer-based methods. Percentages of isolates with complete extended MLST profiles ranged from 99.1% (50 genes) to 86.8% (1,455 genes), while only 41.5% produced a full profile with the gene presence/absence scheme. Replicates demonstrated that all methods offer 100% reproducibility. Indices of discrimination range from 0.972 (ribosomal MLST) to 0.999 (SNP based), and all values were higher than that achieved with SBT (0.940). Epidemiological concordance is generally inversely related to discriminatory power. We propose that an extended MLST scheme with ∼50 genes provides optimal epidemiological concordance while substantially improving the discrimination offered by SBT and can be used as part of a hierarchical typing scheme that should maintain backwards compatibility and increase discrimination where necessary. This analysis will be useful for the ESGLI to design a scheme that has the potential to become the new gold standard typing method for L. pneumophila. Copyright © 2016 David et al.

  4. α-Hydroxyketone Synthesis and Sensing by Legionella and Vibrio

    Directory of Open Access Journals (Sweden)

    Hubert Hilbi

    2012-03-01

    Full Text Available Bacteria synthesize and sense low molecular weight signaling molecules, termed autoinducers, to measure their population density and community complexity. One class of autoinducers, the α-hydroxyketones (AHKs, is produced and detected by the water-borne opportunistic pathogens Legionella pneumophila and Vibrio cholerae, which cause Legionnaires’ disease and cholera, respectively. The “Legionella quorum sensing” (lqs or “cholera quorum sensing” (cqs genes encode enzymes that produce and sense the AHK molecules “Legionella autoinducer-1” (LAI-1; 3-hydroxypentadecane-4-one or cholera autoinducer-1 (CAI-1; 3-hydroxytridecane-4-one. AHK signaling regulates the virulence of L. pneumophila and V. cholerae, pathogen-host cell interactions, formation of biofilms or extracellular filaments, expression of a genomic “fitness island” and competence. Here, we outline the processes, wherein AHK signaling plays a role, and review recent insights into the function of proteins encoded by the lqs and cqs gene clusters. To this end, we will focus on the autoinducer synthases catalysing the biosynthesis of AHKs, on the cognate trans-membrane sensor kinases detecting the signals, and on components of the down-stream phosphorelay cascade that promote the transmission and integration of signaling events regulating gene expression.

  5. Studio del comportamento di Acanthamoeba. polyphaga in presenza di Legionella pneumophila e di altri batteri ad habitat acquatico

    Directory of Open Access Journals (Sweden)

    M. Bondi

    2003-05-01

    Full Text Available Le amebe a vita libera sono state oggetto di diversi studi negli ultimi anni, non solo per le loro potenzialità patogene nei confronti dell’uomo, ma anche per l’importante ruolo che svolgono in natura, dove agiscono come predatori in grado di controllare le popolazioni batteriche. Alcuni degli organismi fagocitati però possono evitare la lisi fagosomiale e mantenere la loro condizione vitale a livello intracellulare, divenendo endosimbionti. Le amebe fungono così da riserva per questi batteri, proteggendoli da difficili condizioni extracellulari e provvedendo ad un ambiente consono alla loro replicazione. Tale tipo di interazione è particolarmente studiata in Legionella pneumophila, dal momento che l’ampia diffusione di questo germe, nonché la sua virulenza, pare siano fortemente influenzate dalla capacità di parassitare protozoi appartenenti ai generi Acanthamoeba, Naegleria e Balamuthia. Al fine di ottenere maggiori informazioni sui fattori favorenti o inibenti lo sviluppo di questi protozoi, è stato studiato il comportamento di un ceppo di Acanthamoeba polyphaga coltivato, in solido e in liquido, in associazione con L. pneumophila ed altri batteri ad habitat acquatico (Pseudomonas, Aeromonas, Achromobacter, Burkholderia. Su tappeti di cellule batteriche allestiti in Non Nutrient Agar (NNA, A.polyphaga si è mostrata in grado di moltiplicarsi utilizzando come nutrimento tutti i ceppi testati, nonostante alcuni, come Burkholderia cepacia SSV6 e Achromobacter xylox SS28, risultino più idonei al suo sviluppo. In piastre a pozzetti addizionate di acqua condottata autoclavata, il protozoo ha mostrato una buona capacità di sopravvivenza, non risultando inoltre influenzato dalla presenza di legionella o dei batteri acquatici testati. Dal momento che, fra i batteri descritti come capaci di vita intra-amebica, sono inclusi patogeni quali Chlamydia, Legionella, Listeria e Rickettsiae, risulta necessario riconsiderare la rilevanza clinica

  6. The TolC protein of Legionella pneumophila plays a major role in multi-drug resistance and the early steps of host invasion.

    Directory of Open Access Journals (Sweden)

    Mourad Ferhat

    Full Text Available Pneumonia associated with Iegionnaires's disease is initiated in humans after inhalation of contaminated aerosols. In the environment, Legionella pneumophila is thought to survive and multiply as an intracellular parasite within free-living amoeba. In the genome of L. pneumophila Lens, we identified a unique gene, tolC, encoding a protein that is highly homologous to the outer membrane protein TolC of Escherichia coli. Deletion of tolC by allelic exchange in L. pneumophila caused increased sensitivity to various drugs. The complementation of the tolC mutation in trans restored drug resistance, indicating that TolC is involved in multi-drug efflux machinery. In addition, deletion of tolC caused a significant attenuation of virulence towards both amoebae and macrophages. Thus, the TolC protein appears to play a crucial role in virulence which could be mediated by its involvement in efflux pump mechanisms. These findings will be helpful in unraveling the pathogenic mechanisms of L. pneumophila as well as in developing new therapeutic agents affecting the efflux of toxic compounds.

  7. Electrochemical Characterization of O2 Plasma Functionalized Multi-Walled Carbon Nanotube Electrode for Legionella pneumophila DNA Sensor

    Science.gov (United States)

    Park, Eun Jin; Lee, Jun-Yong; Hyup Kim, Jun; Kug Kim, Sun; Lee, Cheol Jin; Min, Nam Ki

    2010-08-01

    An electrochemical DNA sensor for Legionella pneumophila detection was constructed using O2 plasma functionalized multi-walled carbon nanotube (MWCNT) film as a working electrode (WE). The cyclic voltammetry (CV) results revealed that the electrocatalytic activity of plasma functionalized MWCNT (pf-MWCNT) significantly changed depending on O2 plasma treatment time due to some oxygen containing functional groups on the pf-MWCNT surface. Scanning electron microscope (SEM) images and X-ray photoelectron spectroscopy (XPS) spectra were also presented the changes of their surface morphologies and oxygen composition before and after plasma treatment. From a comparison study, it was found that the pf-MWCNT WEs had higher electrocatalytic activity and more capability of probe DNA immobilization: therefore, electrochemical signal changes by probe DNA immobilization and hybridization on pf-MWCNT WEs were larger than on Au WEs. The pf-MWCNT based DNA sensor was able to detect a concentration range of 10 pM-100 nM of target DNA to detect L. pneumophila.

  8. Reassessing the role of DotF in the Legionella pneumophila type IV secretion system.

    Directory of Open Access Journals (Sweden)

    Molly C Sutherland

    Full Text Available Legionella pneumophila, the causative agent of a severe pneumonia termed Legionnaires' Disease, survives and replicates within both protozoan hosts and human alveolar macrophages. Intracellular survival is dependent upon secretion of a plethora of protein effectors that function to form a replicative vacuole, evade the endocytic pathway and subvert host immune defenses. Export of these factors requires a type IV secretion system (T4SS called Dot/Icm that is composed of twenty-seven proteins. This report focuses on the DotF protein, which was previously postulated to have several different functions, one of which centered on binding Dot/Icm substrates. In this report, we examined if DotF functions as the T4SS inner membrane receptor for Dot/Icm substrates. Although we were able to recapitulate the previously published bacterial two-hybrid interaction between DotF and several substrates, the interaction was not dependent on the Dot/Icm substrates' signal sequences as predicted for a substrate:receptor interaction. In addition, binding did not require the cytoplasmic domain of DotF, which was anticipated to be involved in recognizing substrates in the cytoplasm. Finally, inactivation of dotF did not abolish intracellular growth of L. pneumophila or translocation of substrates, two phenotypes dependent on the T4SS receptor. These data strongly suggest that DotF does not act as the major receptor for Dot/Icm substrates and therefore likely performs an accessory function within the core-transmembrane subcomplex of the L. pneumophila Dot/Icm type IV secretion system.

  9. Distribution of Legionella and bacterial community composition among regionally diverse US cooling towers.

    Science.gov (United States)

    Llewellyn, Anna C; Lucas, Claressa E; Roberts, Sarah E; Brown, Ellen W; Nayak, Bina S; Raphael, Brian H; Winchell, Jonas M

    2017-01-01

    Cooling towers (CTs) are a leading source of outbreaks of Legionnaires' disease (LD), a severe form of pneumonia caused by inhalation of aerosols containing Legionella bacteria. Accordingly, proper maintenance of CTs is vital for the prevention of LD. The aim of this study was to determine the distribution of Legionella in a subset of regionally diverse US CTs and characterize the associated microbial communities. Between July and September of 2016, we obtained aliquots from water samples collected for routine Legionella testing from 196 CTs located in eight of the nine continental US climate regions. After screening for Legionella by PCR, positive samples were cultured and the resulting Legionella isolates were further characterized. Overall, 84% (164) were PCR-positive, including samples from every region studied. Of the PCR-positive samples, Legionella spp were isolated from 47% (78), L. pneumophila was isolated from 32% (53), and L. pneumophila serogroup 1 (Lp1) was isolated from 24% (40). Overall, 144 unique Legionella isolates were identified; 53% (76) of these were Legionella pneumophila. Of the 76 L. pneumophila isolates, 51% (39) were Lp1. Legionella were isolated from CTs in seven of the eight US regions examined. 16S rRNA amplicon sequencing was used to compare the bacterial communities of CT waters with and without detectable Legionella as well as the microbiomes of waters from different climate regions. Interestingly, the microbial communities were homogenous across climate regions. When a subset of seven CTs sampled in April and July were compared, there was no association with changes in corresponding CT microbiomes over time in the samples that became culture-positive for Legionella. Legionella species and Lp1 were detected frequently among the samples examined in this first large-scale study of Legionella in US CTs. Our findings highlight that, under the right conditions, there is the potential for CT-related LD outbreaks to occur throughout the US.

  10. The DotA protein from Legionella pneumophila is secreted by a novel process that requires the Dot/Icm transporter

    OpenAIRE

    Nagai, Hiroki; Roy, Craig R.

    2001-01-01

    Legionella pneumophila requires the dot/icm genes to create an organelle inside eukaryotic host cells that will support bacterial replication. The dot/icm genes are predicted to encode a type IV-related secretion apparatus. However, no proteins have been identified that require the dot/icm genes for secretion. In this study we show that the DotA protein, which was previously found to be a polytopic membrane protein, is secreted by the Dot/Icm transporter into culture supernatants. Secreted Do...

  11. Legionella-uitbraak in Amsterdam: koeltoren als bron

    NARCIS (Netherlands)

    Hoek, J A R van den; IJzerman, E P F; Coutinho, Roel A

    2006-01-01

    During the period 6-28 July 2006, 30 confirmed cases of Legionella infection were identified in Amsterdam, 2 of which were fatal. All had a positive urinary antigen test, by which Legionella pneumophila serogroup I could be demonstrated. Consultations between the parties involved in the control of

  12. Genetic variability in environmental isolates of Legionella pneumophila from Comunidad Valenciana (Spain).

    Science.gov (United States)

    Coscollá, Mireia; Gosalbes, María José; Catalán, Vicente; González-Candelas, Fernando

    2006-06-01

    Legionella pneumophila is associated to recurrent outbreaks in several Comunidad Valenciana (Spain) localities, especially in Alcoi, where social and climatic conditions seem to provide an excellent environment for bacterial growth. We have analysed the nucleotide sequences of three loci from 25 environmental isolates from Alcoi and nearby locations sampled over 3 years. The analysis of these isolates has revealed a substantial level of genetic variation, with consistent patterns of variability across loci, and comparable to that found in a large, European-wide sampling of clinical isolates. Among the tree loci studied, fliC showed the highest level of nucleotide diversity. The analysis of isolates sampled in different years revealed a clear differentiation, with samples from 2001 being significantly distinct from those obtained in 2002 and 2003. Furthermore, although linkage disequilibrium measures indicate a clonal nature for population structure in this sample, the presence of some recombination events cannot be ruled out.

  13. Differences in Virulence Between Legionella pneumophila Isolates From Human and Non-human Sources Determined in Galleria mellonella Infection Model

    Directory of Open Access Journals (Sweden)

    Patrícia S. Sousa

    2018-04-01

    Full Text Available Legionella pneumophila is a ubiquitous bacterium in freshwater environments and in many man-made water systems capable of inducing pneumonia in humans. Despite its ubiquitous character most studies on L. pneumophila virulence focused on clinical strains and isolates from man-made environments, so little is known about the nature and extent of virulence variation in strains isolated from natural environments. It has been established that clinical isolates are less diverse than man-made and natural environmental strains, suggesting that only a subset of environmental isolates is specially adapted to infect humans. In this work we intended to determine if unrelated L. pneumophila strains, isolated from different environments and with distinct virulence-related genetic backgrounds, displayed differences in virulence, using the Wax Moth Galleria mellonella infection model. We found that all tested strains were pathogenic in G. mellonella, regardless of their origin. Indeed, a panoply of virulence-related phenotypes was observed sustaining the existence of significant differences on the ability of L. pneumophila strains to induce disease. Taken together our results suggest that the occurrence of human infection is not related with the increased capability of some strains to induce disease since we also found a concentration threshold above which L. pneumophila strains are equally able to cause disease. In addition, no link could be established between the sequence-type (ST and L. pneumophila pathogenicity. We envision that in man-made water distribution systems environmental filtering selection and biotic competition acts structuring L. pneumophila populations by selecting more resilient and adapted strains that can rise to high concentration if no control measures are implemented. Therefore, public health strategies based on the sequence based typing (STB scheme analysis should take into account that the major disease-associated clones of L

  14. Efficacy of thermal treatment and copper-silver ionization for controlling Legionella pneumophila in high-volume hot water plumbing systems in hospitals.

    Science.gov (United States)

    Mietzner, S; Schwille, R C; Farley, A; Wald, E R; Ge, J H; States, S J; Libert, T; Wadowsky, R M; Miuetzner, S

    1997-12-01

    Thermal treatment and copper-silver ionization are often used for controlling Legionella pneumophila in high-volume hospital plumbing systems, although the comparative efficacies of these measures in high-volume systems are unknown. Thermal treatment of a hot water circuit was accomplished by flushing hot water (> 60 degrees C) through distal fixtures for 10 minutes. Copper-silver ionization was conducted in three circuits by installing units into return lines immediately upstream from hot water tanks. Recovery rates of L. pneumophila were monitored by culturing swab samples from faucets. Concentrations of copper and silver in water samples were determined by atomic absorption spectrophotometry. Four heat-flush treatments failed to provide long-term control of L. pneumophila. In contrast, ionization treatment reduced the rate of recovery of L. pneumophila from 108 faucets from 72% to 2% within 1 month and maintained effective control for at least 22 months. Only three samples (1.9%) of hot water from faucets exceeded Environmental Protection Agency standards for silver, and none exceeded the standards for copper. Of 24 samples obtained from hot water tanks, 42% and 50% exceeded the silver and copper standards, respectively. Copper-silver ionization effectively controls L. pneumophila in high-volume plumbing systems and is superior to thermal treatment; however, high concentrations of copper and silver can accumulate at the bottom of hot water tanks.

  15. Multiplication of Legionella spp. in tap water containing Hartmannella vermiformis.

    Science.gov (United States)

    Wadowsky, R M; Wilson, T M; Kapp, N J; West, A J; Kuchta, J M; States, S J; Dowling, J N; Yee, R B

    1991-07-01

    A model was developed to study the multiplication of various Legionella spp. in tap water containing Hartmannella vermiformis. Tap water cultures prepared with the following components were suitable for the multiplication studies: Legionella spp., 10(3) CFU/ml; H. vermiformis, 10(4.4) cysts per ml; and killed Pseudomonas paucimobilis, 10(9) cells per ml. Cocultures were incubated at 37 degrees C for at least 1 week. The following legionellae multiplied in tap water cocultures in each replicate experiment: L. bozemanii (WIGA strain), L. dumoffii (NY-23 and TX-KL strains), L. micdadei (two environmental strains), and L. pneumophila (six environmental strains and one clinical isolate). Growth yield values for these strains were 0.6 to 3.5 log CFU/ml. Legionellae which did not multiply in replicate cocultures included L. anisa (one strain), L. bozemanii (MI-15 strain), L. micdadei (a clinical isolate), L. longbeachae, (one strain), and L. pneumophila (Philadelphia 1 strain). L. gormanii and an environmental isolate of L. pneumophila multiplied in only one of three experiments. None of the legionellae multiplied in tap water containing only killed P. paucimobilis. The mean growth yield (+/- standard deviation) of H. vermiformis in the cocultures was 1.2 +/- 0.1 log units/ml. H. vermiformis supports multiplication of only particular strains of legionellae, some of which are from diverse origins.

  16. The presence of opportunistic pathogens, Legionella spp., L. pneumophila and Mycobacterium avium complex, in South Australian reuse water distribution pipelines.

    Science.gov (United States)

    Whiley, H; Keegan, A; Fallowfield, H; Bentham, R

    2015-06-01

    Water reuse has become increasingly important for sustainable water management. Currently, its application is primarily constrained by the potential health risks. Presently there is limited knowledge regarding the presence and fate of opportunistic pathogens along reuse water distribution pipelines. In this study opportunistic human pathogens Legionella spp., L. pneumophila and Mycobacterium avium complex were detected using real-time polymerase chain reaction along two South Australian reuse water distribution pipelines at maximum concentrations of 10⁵, 10³ and 10⁵ copies/mL, respectively. During the summer period of sampling the concentration of all three organisms significantly increased (P < 0.05) along the pipeline, suggesting multiplication and hence viability. No seasonality in the decrease in chlorine residual along the pipelines was observed. This suggests that the combination of reduced chlorine residual and increased water temperature promoted the presence of these opportunistic pathogens.

  17. Comparative assessment of chlorine, heat, ozone, and UV light for killing Legionella pneumophila within a model plumbing system

    International Nuclear Information System (INIS)

    Muraca, P.; Stout, J.E.; Yu, V.L.

    1987-01-01

    Nosocomial Legionnaires disease can be acquired by exposure to the organism from the hospital water distribution system. As a result, many hospitals have instituted eradication procedures, including hypercholorination and thermal eradication. We compared the efficacy of ozonation, UV light, hyperchlorination, and heat eradication using a model plumbing system constructed of copper piping, brass spigots, Plexiglas reservoir, electric hot water tank, and a pump. Legionella pneumophila was added to the system at 10(7) CFU/ml. Each method was tested under three conditions; (i) nonturbid water at 25 degrees C, (ii) turbid water at 25 degrees C, and (iii) nonturbid water at 43 degrees C. UV light and heat killed L. pneumophila most rapidly and required minimal maintenance. Both UV light and heat (60 degrees C) produced a 5 log kill in less than 1 h. In contrast, both chlorine and ozone required 5 h of exposure to produce a 5 log decrease. Neither turbidity nor the higher temperature of 43 degrees C impaired the efficacy of any of the disinfectant methods. Surprisingly, higher temperature enhanced the disinfecting efficacy of chlorine. However, higher temperature accelerated the decomposition of the chlorine residual such that an additional 120% volume of chlorine was required. All four methods proved efficacious in eradicating L. pneumophila from a model plumbing system

  18. Presence of Legionella and Free-Living Amoebae in Composts and Bioaerosols from Composting Facilities

    Science.gov (United States)

    Conza, Lisa; Pagani, Simona Casati; Gaia, Valeria

    2013-01-01

    Several species of Legionella cause Legionnaires’ disease (LD). Infection may occur through inhalation of Legionella or amoebal vesicles. The reservoirs of Legionella are water, soil, potting soil and compost. Some species of free-living amoebae (FLA) that are naturally present in water and soil were described as hosts for Legionella. This study aimed to understand whether or not the composting facilities could be sources of community-acquired Legionella infections after development of bioaerosols containing Legionella or FLA. We looked for the presence of Legionella (by co-culture) and FLA (by culture) in composts and bioaerosols collected at four composting facilities located in southern Switzerland. We investigated the association between the presence of Legionella and compost and air parameters and presence of FLA. Legionella spp. (including L. pneumophila) were detected in 69.3% (61/88) of the composts and FLA (mainly Acanthamoeba, Vermamoeba, Naegleria and Stenamoeba) in 92.0% (81/88). L. pneumophila and L. bozemanii were most frequently isolated. FLA as potential host for Legionella spp. were isolated from 40.9% (36/88) of the composts in all facilities. In Legionella-positive samples the temperature of compost was significantly lower (P = 0.012) than in Legionella-negative samples. Of 47 bioaerosol samples, 19.1% (9/47) were positive for FLA and 10.6% (5/47) for L. pneumophila. Composts (62.8%) were positive for Legionella and FLA contemporaneously, but both microorganisms were never detected simultaneously in bioaerosols. Compost can release bioaerosol containing FLA or Legionella and could represent a source of infection of community-acquired Legionella infections for workers and nearby residents. PMID:23844174

  19. Presence of Legionella and free-living Amoebae in composts and bioaerosols from composting facilities.

    Directory of Open Access Journals (Sweden)

    Lisa Conza

    Full Text Available Several species of Legionella cause Legionnaires' disease (LD. Infection may occur through inhalation of Legionella or amoebal vesicles. The reservoirs of Legionella are water, soil, potting soil and compost. Some species of free-living amoebae (FLA that are naturally present in water and soil were described as hosts for Legionella. This study aimed to understand whether or not the composting facilities could be sources of community-acquired Legionella infections after development of bioaerosols containing Legionella or FLA. We looked for the presence of Legionella (by co-culture and FLA (by culture in composts and bioaerosols collected at four composting facilities located in southern Switzerland. We investigated the association between the presence of Legionella and compost and air parameters and presence of FLA. Legionella spp. (including L. pneumophila were detected in 69.3% (61/88 of the composts and FLA (mainly Acanthamoeba, Vermamoeba, Naegleria and Stenamoeba in 92.0% (81/88. L. pneumophila and L. bozemanii were most frequently isolated. FLA as potential host for Legionella spp. were isolated from 40.9% (36/88 of the composts in all facilities. In Legionella-positive samples the temperature of compost was significantly lower (P = 0.012 than in Legionella-negative samples. Of 47 bioaerosol samples, 19.1% (9/47 were positive for FLA and 10.6% (5/47 for L. pneumophila. Composts (62.8% were positive for Legionella and FLA contemporaneously, but both microorganisms were never detected simultaneously in bioaerosols. Compost can release bioaerosol containing FLA or Legionella and could represent a source of infection of community-acquired Legionella infections for workers and nearby residents.

  20. Legionella Persistence in Manufactured Water Systems: Pasteurization Potentially Selecting for Thermal Tolerance

    Directory of Open Access Journals (Sweden)

    Harriet Whiley

    2017-07-01

    Full Text Available Legionella is an opportunistic waterborne pathogen of increasing public health significance. Pasteurization, otherwise known as super-heat and flush (increasing water temperature to above 70°C and flushing all outlets, has been identified as an important mechanism for the disinfection of Legionella in manufactured water systems. However, several studies have reported that this procedure was ineffective at remediating water distribution systems as Legionella was able to maintain long term persistent contamination. Up to 25% of L. pneumophila cells survived heat treatment of 70°C, but all of these were in a viable but non-culturable state. This demonstrates the limitations of the culture method of Legionella detection currently used to evaluate disinfection protocols. In addition, it has been demonstrated that pasteurization and nutrient starvation can select for thermal tolerant strains, where L. pneumophila was consistently identified as having greater thermal tolerance compared to other Legionella species. This review demonstrates that further research is needed to investigate the effectiveness of pasteurization as a disinfection method. In particular, it focuses on the potential for pasteurization to select for thermal tolerant L. pneumophila strains which, as the primary causative agent of Legionnaires disease, have greater public health significance compared to other Legionella species.

  1. Legionella detection and subgrouping in water air-conditioning cooling tower systems in Kuwait.

    Science.gov (United States)

    Al-Matawah, Qadreyah; Al-Zenki, Sameer; Al-Azmi, Ahmad; Al-Waalan, Tahani; Al-Salameen, Fadila; Hejji, Ahmad Ben

    2015-07-01

    The main aim of the study was to test for the presence of Legionnaires' disease-causing microorganisms in air-conditioned buildings in Kuwait using molecular technologies. For this purpose, 547 samples were collected from 38 cooling towers for the analysis of Legionella pneumophila. These samples included those from water (n = 178), air (n = 231), and swabs (n = 138). Out of the 547 samples, 226 (41%) samples were presumptive positive for L. pneumophila, with L. pneumophila viable counts in the positive water samples ranging from 1 to 88 CFU/ml. Of the Legionella culture-positive samples, 204 isolates were examined by latex agglutination. These isolates were predominately identified as L. pneumophila serogroup (sg) 2-14. Using the Dresden panel of monoclonal antibodies, 74 representatives isolates were further serogrouped. Results showed that 51% of the isolates belonged to serogroup 7 followed by 1 (18%) and 3 (18%). Serogroups 4 (4%) and 10 (7%) were isolated at a lower frequency, and two isolates could not be assigned to a serogroup. These results indicate the wide prevalence of L. pneumophila serogroup 7 as the predominant serogroup at the selected sampling sites. Furthermore, the 74 L. pneumophila (sg1 = 13; sg3 = 13; sg4 = 3; sg7 = 38; sg10 = 5; sgX = 2) isolates were genotyped using the seven gene protocol sequence-based typing (SBT) scheme developed by the European Working Group for Legionella Infections (EWGLI). The results show that Legionella isolates were discriminated into nine distinct sequence typing (ST) profiles, five of which were new to the SBT database of EWGLI. Additionally, all of the ST1 serogroup 1 isolates were of the OLDA/Oxford subgroup. These baseline data will form the basis for the development of a Legionella environmental surveillance program and used for future epidemiological investigations.

  2. Different distribution patterns of ten virulence genes in Legionella reference strains and strains isolated from environmental water and patients.

    Science.gov (United States)

    Zhan, Xiao-Yong; Hu, Chao-Hui; Zhu, Qing-Yi

    2016-04-01

    Virulence genes are distinct regions of DNA which are present in the genome of pathogenic bacteria and absent in nonpathogenic strains of the same or related species. Virulence genes are frequently associated with bacterial pathogenicity in genus Legionella. In the present study, an assay was performed to detect ten virulence genes, including iraA, iraB, lvrA, lvrB, lvhD, cpxR, cpxA, dotA, icmC and icmD in different pathogenicity islands of 47 Legionella reference strains, 235 environmental strains isolated from water, and 4 clinical strains isolated from the lung tissue of pneumonia patients. The distribution frequencies of these genes in reference or/and environmental L. pneumophila strains were much higher than those in reference non-L. pneumophila or/and environmental non-L. pneumophila strains, respectively. L. pneumophila clinical strains also maintained higher frequencies of these genes compared to four other types of Legionella strains. Distribution frequencies of these genes in reference L. pneumophila strains were similar to those in environmental L. pneumophila strains. In contrast, environmental non-L. pneumophila maintained higher frequencies of these genes compared to those found in reference non-L. pneumophila strains. This study illustrates the association of virulence genes with Legionella pathogenicity and reveals the possible virulence evolution of non-L. pneumophia strains isolated from environmental water.

  3. SULFAMETHOXAZOLE-TRIMETHOPRIM TREATMENT OF GUINEA PIGS INFECTED WITH 'LEGIONELLA PNEUMPOPHILA'

    Science.gov (United States)

    Legionnaires' disease is a bacterial pneumonia caused by Legionella pneumophila. Many antibiotics inhibit the growth of L. pneumophila in vitro, but only erythromycin and rifampin have been clinically effective. Parallel results have been observed in guinea pigs infected ip with ...

  4. Proteomic analysis of growth phase-dependent expression of Legionella pneumophila proteins which involves regulation of bacterial virulence traits.

    Directory of Open Access Journals (Sweden)

    Tsuyoshi Hayashi

    Full Text Available Legionella pneumophila, which is a causative pathogen of Legionnaires' disease, expresses its virulent traits in response to growth conditions. In particular, it is known to become virulent at a post-exponential phase in vitro culture. In this study, we performed a proteomic analysis of differences in expression between the exponential phase and post-exponential phase to identify candidates associated with L. pneumophila virulence using 2-Dimentional Fluorescence Difference Gel Electrophoresis (2D-DIGE combined with Matrix-Assisted Laser Desorption/Ionization-Mass Spectrometry (MALDI-TOF-MS. Of 68 identified proteins that significantly differed in expression between the two growth phases, 64 were up-regulated at a post-exponential phase. The up-regulated proteins included enzymes related to glycolysis, ketone body biogenesis and poly-3-hydroxybutyrate (PHB biogenesis, suggesting that L. pneumophila may utilize sugars and lipids as energy sources, when amino acids become scarce. Proteins related to motility (flagella components and twitching motility-associated proteins were also up-regulated, predicting that they enhance infectivity of the bacteria in host cells under certain conditions. Furthermore, 9 up-regulated proteins of unknown function were found. Two of them were identified as novel bacterial factors associated with hemolysis of sheep red blood cells (SRBCs. Another 2 were found to be translocated into macrophages via the Icm/Dot type IV secretion apparatus as effector candidates in a reporter assay with Bordetella pertussis adenylate cyclase. The study will be helpful for virulent analysis of L. pneumophila from the viewpoint of physiological or metabolic modulation dependent on growth phase.

  5. Identification of mip-like genes in the genus Legionella

    DEFF Research Database (Denmark)

    Cianciotto, N P; Bangsborg, Jette Marie; Eisenstein, B I

    1990-01-01

    The mip gene of Legionella pneumophila serogroup 1 strain AA100 encodes a 24-kilodalton surface protein (Mip) and enhances the abilities of L. pneumophila to parasitize human macrophages and to cause pneumonia in experimental animals. To determine whether this virulence factor is conserved in the...

  6. Cross-reactive Legionella antigens and the antibody response during infection

    DEFF Research Database (Denmark)

    Bangsborg, Jette Marie; Shand, G; Pearlman, E

    1991-01-01

    In order to define cross-reactive Legionella antigens suitable for diagnostic purposes, we investigated sonicate antigens from two Legionella species, including two serogroups of L. pneumophila. The antigens were reacted with heterologous and homologous rabbit antisera in Western blot. Sera from ...

  7. Real-time PCR to supplement gold-standard culture-based detection of Legionella in environmental samples.

    Science.gov (United States)

    Collins, S; Jorgensen, F; Willis, C; Walker, J

    2015-10-01

    Culture remains the gold-standard for the enumeration of environmental Legionella. However, it has several drawbacks including long incubation and poor sensitivity, causing delays in response times to outbreaks of Legionnaires' disease. This study aimed to validate real-time PCR assays to quantify Legionella species (ssrA gene), Legionella pneumophila (mip gene) and Leg. pneumophila serogroup-1 (wzm gene) to support culture-based detection in a frontline public health laboratory. Each qPCR assay had 100% specificity, excellent sensitivity (5 GU/reaction) and reproducibility. Comparison of the assays to culture-based enumeration of Legionella from 200 environmental samples showed that they had a negative predictive value of 100%. Thirty eight samples were positive for Legionella species by culture and qPCR. One hundred samples were negative by both methods, whereas 62 samples were negative by culture but positive by qPCR. The average log10 increase between culture and qPCR for Legionella spp. and Leg. pneumophila was 0·72 (P = 0·0002) and 0·51 (P = 0·006), respectively. The qPCR assays can be conducted on the same 1 l water sample as culture thus can be used as a supplementary technique to screen out negative samples and allow more rapid indication of positive samples. The assay could prove informative in public health investigations to identify or rule out sources of Legionella as well as to specifically identify Leg. pneumophila serogroup 1 in a timely manner not possible with culture. © 2015 The Society for Applied Microbiology.

  8. Essential roles and regulation of the Legionella pneumophila collagen-like adhesin during biofilm formation.

    Directory of Open Access Journals (Sweden)

    Julia Mallegol

    Full Text Available Legionellosis is mostly caused by Legionella pneumophila (Lp and is defined by a severe respiratory illness with a case fatality rate ranging from 5 to 80%. In a previous study, we showed that a glycosaminoglycan (GAG-binding adhesin of Lp, named Lcl, is produced during legionellosis and is unique to the L. pneumophila species. Importantly, a mutant depleted in Lcl (Δlpg2644 is impaired in adhesion to GAGs and epithelial cells and in biofilm formation. Here, we examine the molecular function(s of Lcl and the transcriptional regulation of its encoding gene during different stages of the biofilm development. We show that the collagen repeats and the C-terminal domains of Lcl are crucial for the production of biofilm. We present evidence that Lcl is involved in the early step of surface attachment but also in intercellular interactions. Furthermore, we address the relationship between Lcl gene regulation during biofilm formation and quorum sensing (QS. In a static biofilm assay, we show that Lcl is differentially regulated during growth phases and biofilm formation. Moreover, we show that the transcriptional regulation of lpg2644, mediated by a prototype of QS signaling homoserine lactone (3OC12-HSL, may play a role during the biofilm development. Thus, transcriptional down-regulation of lpg2644 may facilitate the dispersion of Lp to reinitiate biofilm colonization on a distal surface.

  9. Influenceof antimicrobial therapy on the sensitivity of legionella PCR - three case report

    Directory of Open Access Journals (Sweden)

    Renato Eržen

    2007-02-01

    Full Text Available Background: L. pneumophila is a possible causative agent of severe community and hospital acquired pneumonia. Available diagnostic tests have a lot of shortcomings. Detection of Legionella DNA with the PCR technique is a promissing new method allowing diagnosis within clinically useful time.Methods: Three cases of severe Legionella pneumonia were followed with the PCR technique, urinary antigen and serologic methods.Results: Diagnostic tests have different sensitivity and specificity and also different shortcomings. Serologic tests are unable to provide diagnosis within clinically useful time. Urinary antigen is specific just for L. pneumophila serotype 1. Antimicrobial treatment has impact on the sensitivity of Legionella PCR.Conclusions: Detection of L. pneumophila infection with the PCR technique in addition to urinary antigen testing is likely to be the best diagnostic tool for the detection of all species within a time frame that will affect clinical management.

  10. The use of heteroduplex analysis of polymerase chain reaction products to support the possible transmission of Legionella pneumophila from a malfunctioning automobile air conditioner.

    Science.gov (United States)

    Pinar, Ahmet; Ramirez, Julio A; Schindler, Laura L; Miller, Richard D; Summersgill, James T

    2002-03-01

    Air conditioner condensates have not been previously associated with cases of Legionnaires' disease. We report the possible transmission of Legionella pneumophila serogroup 1 from a malfunctioning automobile air conditioning system's leaking water onto the floorboard of a car driven for a long distance by the patient. Heteroduplex analysis of polymerase chain reaction products was used to help establish an epidemiologic link between the water specimen and the patient.

  11. A case of nosocomial Legionella pneumonia associated with a contaminated hospital cooling tower.

    Science.gov (United States)

    Osawa, Kayo; Shigemura, Katsumi; Abe, Yasuhisa; Jikimoto, Takumi; Yoshida, Hiroyuki; Fujisawa, Masato; Arakawa, Soichi

    2014-01-01

    We report the epidemiological investigation of a nosocomial pneumonia case due to Legionella pneumophila linked to a contaminated hospital cooling tower in an immune-compromised patient. A 73-year-old female patient was diagnosed with nosocomial Legionella pneumonia proven by a culture of L. pneumophila serogroup 1 from bronchoalveolar lavage fluid. Two strains isolated from the patient and two strains isolated from two cooling towers were found to be identical using repetitive-sequence-based-PCR with a 95% probability. This Legionella pneumonia case might be caused by aerosol from cooling towers on the roof of the hospital building which was contaminated by L. pneumophila. We increased up the temperature of hot water supply appropriately for prevention of Legionella breeding in an environment of patients' living. On the other hand, as the maintenance of cooling tower, we increased the frequency of Legionella culture tests from twice a year to three times a year. In addition, we introduced an automated disinfectants insertion machine and added one antiseptic reagent (BALSTER ST-40 N, Tohzai Chemical Industry Co., Ltd., Kawasaki, Japan) after this Legionella disease, and thereafter, we have no additional cases of Legionella disease or detection of Legionella spp. from the cooling tower or hot water supply. This case demonstrates the importance of detecting the infection source and carrying out environmental maintenance in cooperation with the infection control team. Copyright © 2013 Japanese Society of Chemotherapy and the Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  12. Exploring Anti-Bacterial Compounds against Intracellular Legionella

    Science.gov (United States)

    Harrison, Christopher F.; Kicka, Sébastien; Trofimov, Valentin; Berschl, Kathrin; Ouertatani-Sakouhi, Hajer; Ackermann, Nikolaus; Hedberg, Christian; Cosson, Pierre; Soldati, Thierry; Hilbi, Hubert

    2013-01-01

    Legionella pneumophila is a ubiquitous fresh-water bacterium which reproduces within its erstwhile predators, environmental amoeba, by subverting the normal pathway of phagocytosis and degradation. The molecular mechanisms which confer resistance to amoeba are apparently conserved and also allow replication within macrophages. Thus, L. pneumophila can act as an ‘accidental’ human pathogen and cause a severe pneumonia known as Legionnaires’ disease. The intracellular localisation of L. pneumophila protects it from some antibiotics, and this fact must be taken into account to develop new anti-bacterial compounds. In addition, the intracellular lifestyle of L. pneumophila may render the bacteria susceptible to compounds diminishing bacterial virulence and decreasing intracellular survival and replication of this pathogen. The development of a single infection cycle intracellular replication assay using GFP-producing L. pneumophila and Acanthamoeba castellanii amoeba is reported here. This fluorescence-based assay allows for continuous monitoring of intracellular replication rates, revealing the effect of bacterial gene deletions or drug treatment. To examine how perturbations of the host cell affect L. pneumophila replication, several known host-targeting compounds were tested, including modulators of cytoskeletal dynamics, vesicle scission and Ras GTPase localisation. Our results reveal a hitherto unrealized potential antibiotic property of the β-lactone-based Ras depalmitoylation inhibitor palmostatin M, but not the closely related inhibitor palmostatin B. Further characterisation indicated that this compound caused specific growth inhibition of Legionella and Mycobacterium species, suggesting that it may act on a common bacterial target. PMID:24058631

  13. Exploring anti-bacterial compounds against intracellular Legionella.

    Directory of Open Access Journals (Sweden)

    Christopher F Harrison

    Full Text Available Legionella pneumophila is a ubiquitous fresh-water bacterium which reproduces within its erstwhile predators, environmental amoeba, by subverting the normal pathway of phagocytosis and degradation. The molecular mechanisms which confer resistance to amoeba are apparently conserved and also allow replication within macrophages. Thus, L. pneumophila can act as an 'accidental' human pathogen and cause a severe pneumonia known as Legionnaires' disease. The intracellular localisation of L. pneumophila protects it from some antibiotics, and this fact must be taken into account to develop new anti-bacterial compounds. In addition, the intracellular lifestyle of L. pneumophila may render the bacteria susceptible to compounds diminishing bacterial virulence and decreasing intracellular survival and replication of this pathogen. The development of a single infection cycle intracellular replication assay using GFP-producing L. pneumophila and Acanthamoebacastellanii amoeba is reported here. This fluorescence-based assay allows for continuous monitoring of intracellular replication rates, revealing the effect of bacterial gene deletions or drug treatment. To examine how perturbations of the host cell affect L. pneumophila replication, several known host-targeting compounds were tested, including modulators of cytoskeletal dynamics, vesicle scission and Ras GTPase localisation. Our results reveal a hitherto unrealized potential antibiotic property of the β-lactone-based Ras depalmitoylation inhibitor palmostatin M, but not the closely related inhibitor palmostatin B. Further characterisation indicated that this compound caused specific growth inhibition of Legionella and Mycobacterium species, suggesting that it may act on a common bacterial target.

  14. Identification of Variable-Number Tandem-Repeat (VNTR) Sequences in Legionella pneumophila and Development of an Optimized Multiple-Locus VNTR Analysis Typing Scheme▿

    Science.gov (United States)

    Pourcel, Christine; Visca, Paolo; Afshar, Baharak; D'Arezzo, Silvia; Vergnaud, Gilles; Fry, Norman K.

    2007-01-01

    The utility of a genotypic typing assay for Legionella pneumophila was investigated. A multiple-locus variable number of tandem repeats (VNTR) analysis (MLVA) scheme using PCR and agarose gel electrophoresis is proposed based on eight minisatellite markers. Panels of well-characterized strains were examined in a multicenter analysis to validate the assay and to compare its performance to that of other genotyping assays. Excellent typeability, reproducibility, stability, and epidemiological concordance were observed. The MLVA type or profile is composed of a string of allele numbers, corresponding to the number of repeats at each VNTR locus, separated by commas, in a predetermined order. A database containing information from 99 L. pneumophila serogroup 1 strains and four strains of other serogroups and their MLVA profiles, which can be queried online, is available from http://bacterial-genotyping.igmors.u-psud.fr/. PMID:17251393

  15. Legionella clemsonensis sp. nov.: a green fluorescing Legionella strain from a patient with pneumonia.

    Science.gov (United States)

    Palmer, Allison; Painter, Joseph; Hassler, Hayley; Richards, Vincent P; Bruce, Terri; Morrison, Shatavia; Brown, Ellen; Kozak-Muiznieks, Natalia A; Lucas, Claressa; McNealy, Tamara L

    2016-10-01

    A novel Legionella species was identified based on sequencing, cellular fatty acid analysis, biochemical reactions, and biofilm characterization. Strain D5610 was originally isolated from the bronchial wash of a patient in Ohio, USA. The bacteria were gram-negative, rod-shaped, and exhibited green fluorescence under long wave UV light. Phylogenetic analysis and fatty acid composition revealed a distinct separation within the genus. The strain grows between 26-45°C and forms biofilms equivalent to L. pneumophila Philadelphia 1. These characteristics suggest that this isolate is a novel Legionella species, for which the name Legionella clemsonensis sp nov. is proposed. © 2016 The Societies and John Wiley & Sons Australia, Ltd.

  16. Automobile windshield washer fluid: A potential source of transmission for Legionella

    International Nuclear Information System (INIS)

    Schwake, David Otto; Alum, Absar; Abbaszadegan, Morteza

    2015-01-01

    Epidemiological evidence suggesting driving cars to be a risk factor for legionellosis has prompted public health studies to investigate vehicle windshield washer fluid as a novel transmission source of this disease. The goal of the current study was to investigate whether or not windshield washer fluid could serve as a potential source of transmission for Legionella. A wide variation in the survival of L. pneumophila was observed when incubated in different washer fluids at 25 and 37 °C, however, one brand tested supported Legionella survival similar to or greater than sterilized deionized water. In addition, 1 L of tap water contained in a washer fluid reservoir was able to support population growth and survival of Legionella for several months. In a field study examining the windshield washer fluid of 12 elementary school buses, Legionella were detected from 84% of samples at a high concentration of 8.1 × 10 4 CFU/mL. Culturable cells were also detected in aerosolized washer fluid during washer fluid spray. By demonstrating survival in certain windshield washer fluids, growth within washer fluid reservoirs, and the presence of viable cells in bus washer fluid spray, we have provided evidence suggesting the potential for a novel route of Legionella exposure. - Highlights: • L. pneumophila survival in one brand of washer fluid and sterilized deionized water were similar. • Legionella population was maintained in tap water for several months. • Culturable Legionella were detected in 10 of 12 school bus washer fluid reservoirs sampled. • Legionella concentrations up to 8.1 × 104 CFU/mL were detected in school bus washer fluid. • L. pneumophila was detected in washer fluid reservoirs and aerosolized washer fluid

  17. Automobile windshield washer fluid: A potential source of transmission for Legionella

    Energy Technology Data Exchange (ETDEWEB)

    Schwake, David Otto [School of Life Sciences, Arizona State University, P.O. Box 875306, Tempe, AZ 85287 (United States); Alum, Absar [School of Sustainable Engineering and the Built Environment, Arizona State University, P.O. Box 875306, Tempe, AZ 85287 (United States); Abbaszadegan, Morteza, E-mail: abbaszadegan@asu.edu [School of Sustainable Engineering and the Built Environment, Arizona State University, P.O. Box 875306, Tempe, AZ 85287 (United States)

    2015-09-01

    Epidemiological evidence suggesting driving cars to be a risk factor for legionellosis has prompted public health studies to investigate vehicle windshield washer fluid as a novel transmission source of this disease. The goal of the current study was to investigate whether or not windshield washer fluid could serve as a potential source of transmission for Legionella. A wide variation in the survival of L. pneumophila was observed when incubated in different washer fluids at 25 and 37 °C, however, one brand tested supported Legionella survival similar to or greater than sterilized deionized water. In addition, 1 L of tap water contained in a washer fluid reservoir was able to support population growth and survival of Legionella for several months. In a field study examining the windshield washer fluid of 12 elementary school buses, Legionella were detected from 84% of samples at a high concentration of 8.1 × 10{sup 4} CFU/mL. Culturable cells were also detected in aerosolized washer fluid during washer fluid spray. By demonstrating survival in certain windshield washer fluids, growth within washer fluid reservoirs, and the presence of viable cells in bus washer fluid spray, we have provided evidence suggesting the potential for a novel route of Legionella exposure. - Highlights: • L. pneumophila survival in one brand of washer fluid and sterilized deionized water were similar. • Legionella population was maintained in tap water for several months. • Culturable Legionella were detected in 10 of 12 school bus washer fluid reservoirs sampled. • Legionella concentrations up to 8.1 × 104 CFU/mL were detected in school bus washer fluid. • L. pneumophila was detected in washer fluid reservoirs and aerosolized washer fluid.

  18. Tracking Legionella in air generated from a biological treatment plant: a case study of the outbreak of legionellosis in Norway

    Science.gov (United States)

    Blatny, Janet M.; Olsen, Jaran S.; Andreassen, Øyvind; Waagen, Viggo; Reif, Bjørn Anders P.

    2011-05-01

    Two outbreaks of legionellosis occurred in the Sarpsborg/Fredrikstad region southeast of Norway in 2005 and 2008 where more than 60 exposed individuals were infected and 10 case patients died. The air scrubber at Borregaard, a wood-based chemical factory, was identified as the outbreak source. High concentration levels of Legionella species, including the etiological agent L. pneumophila SG1 was found in the aeration ponds, which belongs to Borregaard's biological treatment plant. Results showed that these ponds were able to generate Legionella-containing aerosols that were transported by the wind as such aerosols were measured up to 200 meters downwind of the pond. Our studies did not detect L. pneumophila SG1 isolates, only L. pneumophila SG4 during the air sampling measurement campaign. Furthermore, the operational conditions of the air scrubber proved to be harsh for Legionella growth as the outbreak L. pneumophila strains were not able to grow at 45ºC and pH8 (conditions during the outbreaks). These results, together, lead us to suggest that the aeration pond should be regarded as the primary amplifier and disseminator of Legionella and L. pneumophila and thereby most likely being the outbreak source.

  19. Legionella pneumophila infection presenting as headache, confusion and dysarthria in a human immunodeficiency virus-1 (HIV-1 positive patient: case report

    Directory of Open Access Journals (Sweden)

    Robbins Nathaniel M

    2012-09-01

    Full Text Available Abstract Background Legionella pneumophila is a common cause of community-acquired pneumonia. Central nervous system dysfunction is common, and diagnosis in the absence of pulmonary symptoms can be challenging. Here we describe an atypical clinical presentation of Legionella infection in a patient with HIV who was found to have an unusual neuroradiologic lesion that further served to obscure the diagnosis. This is the first such description in a patient with Legionellosis and HIV coinfection. Case presentation A 43 year-old HIV positive man presented to our hospital with dysarthria, fevers, headache, and altered mental status. Initial work-up revealed pneumonia and a lesion of the splenium of the corpus callosum on magnetic resonance imaging. He was subsequently diagnosed with Legionella pneumonia and treated with complete symptom resolution. Conclusions Neurologic abnormalities are frequent in Legionellosis, but the diagnosis may be difficult in the absence of overt respiratory symptoms and in the presence of HIV coinfection. A high index of suspicion and early initiation of empiric antibiotics is imperative since early treatment may help prevent long-term sequelae. Neuroimaging abnormalities, though rare, can help the physician narrow down the diagnosis and avoid unnecessary invasive testing. Future studies should aim to elucidate the as yet unknown role of neuroimaging in the diagnoses and prognostication of Legionellosis, as well as the interaction between Legionella infection and HIV.

  20. Synthese und Charakterisierung von potenziellen Inhibitoren des „Macrophage infectivity potentiator“ (Mip) Proteins von Legionella pneumophila - Ein neuer Ansatz in der Legionellose-Therapie

    OpenAIRE

    Juli, Christina

    2012-01-01

    Die vorliegende Arbeit beschäftigt sich mit der Synthese und Charakterisierung potenzieller Inhibitoren des Oberflächenproteins Mip von Legionella pneumophila. Der gramnegative Mikroorganismus ist der ursächliche Erreger der Legionellose. Die Erkrankung kann in zwei verschiedenen Formen auftreten, dem Pontiac-Fieber, einer Grippe-ähnlichen Atemwegserkrankung, und der Legionärskrankheit, einer schweren Lungenentzündung mit einer Mortalitätsrate von bis zu 30 %. Natürliche und künstlich geschaf...

  1. Comprehensive identification of protein substrates of the Dot/Icm type IV transporter of Legionella pneumophila.

    Directory of Open Access Journals (Sweden)

    Wenhan Zhu

    2011-03-01

    Full Text Available A large number of proteins transferred by the Legionella pneumophila Dot/Icm system have been identified by various strategies. With no exceptions, these strategies are based on one or more characteristics associated with the tested proteins. Given the high level of diversity exhibited by the identified proteins, it is possible that some substrates have been missed in these screenings. In this study, we took a systematic method to survey the L. pneumophila genome by testing hypothetical orfs larger than 300 base pairs for Dot/Icm-dependent translocation. 798 of the 832 analyzed orfs were successfully fused to the carboxyl end of β-lactamase. The transfer of the fusions into mammalian cells was determined using the β-lactamase reporter substrate CCF4-AM. These efforts led to the identification of 164 proteins positive in translocation. Among these, 70 proteins are novel substrates of the Dot/Icm system. These results brought the total number of experimentally confirmed Dot/Icm substrates to 275. Sequence analysis of the C-termini of these identified proteins revealed that Lpg2844, which contains few features known to be important for Dot/Icm-dependent protein transfer can be translocated at a high efficiency. Thus, our efforts have identified a large number of novel substrates of the Dot/Icm system and have revealed the diverse features recognizable by this protein transporter.

  2. Population structure of Legionella spp. from environmental samples in Gabon, 2013.

    Science.gov (United States)

    Ehrhardt, Jonas; Alabi, Abraham S; Kuczius, Thorsten; Tsombeng, Francis Foguim; Becker, Karsten; Kremsner, Peter G; Schaumburg, Frieder; Esen, Meral

    2015-07-01

    Aquatic environments are the most important source for Legionella spp. infections such as Legionnaires' disease and Pontiac fever. The reservoirs of Legionella spp. are mostly unclear in sub-Saharan Africa. The aim of this study, conducted in 2013, was to identify geographical areas of an increased risk for exposure to Legionella spp., and to describe the population structure of Legionella spp. from different water sources in a cross-sectional study in Gabon. Fresh water samples (n = 200) were cultured on Legionella selective agar; species were confirmed by MALDI-TOF, a Legionella pneumophila specific real-time PCR and 16S RNA gene sequencing. Serogroups were identified by agglutination test. The population structure was assessed by multilocus sequence typing (MLST). Legionella spp. isolates (n = 29) were frequently found in the hospital setting particularly in hot water systems. Open water bodies (i.e. rivers, lakes) were not contaminated with Legionella spp. Isolated L. pneumophila mainly belonged to serogroups 2-14 (n = 19) and MLST sequence type ST1, ST75 (and related STs) and ST1911. In conclusion, hospitalized patients might have an increased risk to become infected with Legionella spp. in the studied areas in Gabon, particularly if they have risk factors such as comorbidities. Both broadly extended (ST1, ST75) and local lineages (ST1911) were present in our setting. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Effect of temperature and colonization of Legionella pneumophila and Vermamoeba vermiformis on bacterial community composition of copper drinking water biofilms.

    Science.gov (United States)

    Buse, Helen Y; Ji, Pan; Gomez-Alvarez, Vicente; Pruden, Amy; Edwards, Marc A; Ashbolt, Nicholas J

    2017-07-01

    It is unclear how the water-based pathogen, Legionella pneumophila (Lp), and associated free-living amoeba (FLA) hosts change or are changed by the microbial composition of drinking water (DW) biofilm communities. Thus, this study characterized the bacterial community structure over a 7-month period within mature (> 600-day-old) copper DW biofilms in reactors simulating premise plumbing and assessed the impact of temperature and introduction of Lp and its FLA host, Vermamoeba vermiformis (Vv), co-cultures (LpVv). Sequence and quantitative PCR (qPCR) analyses indicated a correlation between LpVv introduction and increases in Legionella spp. levels at room temperature (RT), while at 37°C, Lp became the dominant Legionella spp. qPCR analysis suggested Vv presence may not be directly associated with Lp biofilm growth at RT and 37°C, but may contribute to or be associated with non-Lp legionellae persistence at RT. Two-way PERMANOVA and PCoA revealed that temperature was a major driver of microbiome diversity. Biofilm community composition also changed over the seven-month period and could be associated with significant shifts in dissolved oxygen, alkalinity and various metals in the influent DW. Hence, temperature, biofilm age, DW quality and transient intrusions/amplification of pathogens and FLA hosts may significantly impact biofilm microbiomes and modulate pathogen levels over extended periods. © 2016 The Authors. Microbial Biotechnology published by John Wiley & Sons Ltd and Society for Applied Microbiology.

  4. RavN is a member of a previously unrecognized group of Legionella pneumophila E3 ubiquitin ligases

    Science.gov (United States)

    Lin, Yi-Han; Evans, Timothy R.; Doms, Alexandra G.; Beauchene, Nicole A.; Hierro, Aitor

    2018-01-01

    The eukaryotic ubiquitylation machinery catalyzes the covalent attachment of the small protein modifier ubiquitin to cellular target proteins in order to alter their fate. Microbial pathogens exploit this post-translational modification process by encoding molecular mimics of E3 ubiquitin ligases, eukaryotic enzymes that catalyze the final step in the ubiquitylation cascade. Here, we show that the Legionella pneumophila effector protein RavN belongs to a growing class of bacterial proteins that mimic host cell E3 ligases to exploit the ubiquitylation pathway. The E3 ligase activity of RavN was located within its N-terminal region and was dependent upon interaction with a defined subset of E2 ubiquitin-conjugating enzymes. The crystal structure of the N-terminal region of RavN revealed a U-box-like motif that was only remotely similar to other U-box domains, indicating that RavN is an E3 ligase relic that has undergone significant evolutionary alteration. Substitution of residues within the predicted E2 binding interface rendered RavN inactive, indicating that, despite significant structural changes, the mode of E2 recognition has remained conserved. Using hidden Markov model-based secondary structure analyses, we identified and experimentally validated four additional L. pneumophila effectors that were not previously recognized to possess E3 ligase activity, including Lpg2452/SdcB, a new paralog of SidC. Our study provides strong evidence that L. pneumophila is dedicating a considerable fraction of its effector arsenal to the manipulation of the host ubiquitylation pathway. PMID:29415051

  5. Ecology of Legionella within water cooling circuits of nuclear power plants along the French Loire River

    International Nuclear Information System (INIS)

    Jakubek, Delphine

    2012-01-01

    The cooling circuits of nuclear power plants, by their mode of operating, can select thermophilic microorganisms including the pathogenic organism Legionella pneumophila. To control the development of this genus, a disinfection treatment of water cooling systems with monochloramine can be used. To participate in the management of health and environmental risks associated with the physico-chemical and microbiological modification of water collected from the river, EDF is committed to a process of increasing knowledge about the ecology of Legionella in cooling circuits and its links with its environment (physical, chemical and microbiological) supporting or not their proliferation. Thus, diversity and dynamics of culturable Legionella pneumophila were determined in the four nuclear power plants along the Loire for a year and their links with physico-chemical and microbiological parameters were studied. This study revealed a high diversity of Legionella pneumophila subpopulations and their dynamic seems to be related to the evolution of a small number of subpopulations. Legionella subpopulations seem to maintain strain-specific relationships with biotic parameters and present different sensitivities to physico-chemical variations. The design of cooling circuits could impact the Legionella community. The use of monochloramine severely disrupts the ecosystem but does not select biocide tolerant subpopulations. (author)

  6. Metabolism of the vacuolar pathogen Legionella and implications for virulence.

    Science.gov (United States)

    Manske, Christian; Hilbi, Hubert

    2014-01-01

    Legionella pneumophila is a ubiquitous environmental bacterium that thrives in fresh water habitats, either as planktonic form or as part of biofilms. The bacteria also grow intracellularly in free-living protozoa as well as in mammalian alveolar macrophages, thus triggering a potentially fatal pneumonia called "Legionnaires' disease." To establish its intracellular niche termed the "Legionella-containing vacuole" (LCV), L. pneumophila employs a type IV secretion system and translocates ~300 different "effector" proteins into host cells. The pathogen switches between two distinct forms to grow in its extra- or intracellular niches: transmissive bacteria are virulent for phagocytes, and replicative bacteria multiply within their hosts. The switch between these forms is regulated by different metabolic cues that signal conditions favorable for replication or transmission, respectively, causing a tight link between metabolism and virulence of the bacteria. Amino acids represent the prime carbon and energy source of extra- or intracellularly growing L. pneumophila. Yet, the genome sequences of several Legionella spp. as well as transcriptome and proteome data and metabolism studies indicate that the bacteria possess broad catabolic capacities and also utilize carbohydrates such as glucose. Accordingly, L. pneumophila mutant strains lacking catabolic genes show intracellular growth defects, and thus, intracellular metabolism and virulence of the pathogen are intimately connected. In this review we will summarize recent findings on the extra- and intracellular metabolism of L. pneumophila using genetic, biochemical and cellular microbial approaches. Recent progress in this field sheds light on the complex interplay between metabolism, differentiation and virulence of the pathogen.

  7. [Comparison and evaluation of the Binax EIA and Biotest EIA urinary antigen kits for detection of Legionella pneumophila antigen in urine samples].

    Science.gov (United States)

    Rastawicki, Waldemar; Rokosz, Natalia; Jagielski, Marek

    2011-01-01

    The Binax and the Biotest urinary antigen kits for detection of L. pneumophila antigen were compared by testing of selected 67 urine samples obtained from EWGLI as reference samples in External Quality Assessment Scheme. Thirty nine were positive with the Binax kit (100% of sensitivity), and 33 were positive with the Biotest (84.6% of sensitivity). The test specificities were 100% for the both kits. It was concluded that the Binax kit was more suitable for the routine diagnosis of Legionella infections than the Biotest kit.

  8. Recreational Vehicle Water Tanks as a Possible Source for Legionella Infections

    Directory of Open Access Journals (Sweden)

    Christine M. Litwin

    2013-01-01

    Full Text Available We investigated recreational vehicle (RV water reservoirs in response to a case of pneumonia in which Legionella pneumophila was cultured both from the patient and a RV reservoir in which he travelled. Water samples processed and cultured at the CDC according to standard protocol were positive for Legionella spp. in 4/17 (24% faucets, 1/11 (9% water tanks from 4/20 (20% RVs from three different campsites. Legionella spp. that were isolated included L. pneumophila (serogroups 1 and 6, L. anisa, L. feeleii, and L. quateriensis. Environmental controls from the potable water of the three campsites were culture-negative. A survey of maintenance practices by the RV users at the campsites revealed that chlorine disinfection of the water tanks was rarely performed. To prevent the possibility of Legionella infections, RV owners should implement regular chlorine disinfection of their water tanks and follow the recommended maintenance guidelines according to their owner's manuals.

  9. UV-A photocatalytic treatment of Legionella pneumophila bacteria contaminated airflows through three-dimensional solid foam structured photocatalytic reactors

    Energy Technology Data Exchange (ETDEWEB)

    Josset, Sebastien; Hajiesmaili, Shabnam; Begin, Dominique; Edouard, David; Pham-Huu, Cuong [Laboratoire des Materiaux, Surfaces et Procedes pour la Catalyse (LMSPC), European Laboratory for Catalysis and Surface Sciences (ELCASS), CNRS, Strasbourg University, 25 rue Becquerel 67087 Strasbourg (France); Lett, Marie-Claire [Laboratoire de Genetique Moleculaire, Genomique, Microbiologie, CNRS, Strasbourg University, 28, rue Goethe 67083 Strasbourg Cedex (France); Keller, Nicolas, E-mail: nkeller@chimie.u-strasbg.fr [Laboratoire des Materiaux, Surfaces et Procedes pour la Catalyse (LMSPC), European Laboratory for Catalysis and Surface Sciences (ELCASS), CNRS, Strasbourg University, 25 rue Becquerel 67087 Strasbourg (France); Keller, Valerie [Laboratoire des Materiaux, Surfaces et Procedes pour la Catalyse (LMSPC), European Laboratory for Catalysis and Surface Sciences (ELCASS), CNRS, Strasbourg University, 25 rue Becquerel 67087 Strasbourg (France)

    2010-03-15

    A 3D-structured photocatalytic media was designed for allowing a tubular reactor to work in a traversing-flow mode at low pressure drops with a strong increase in the surface area-to-volume ratio inside the reactor. A protective polysiloxane coating was performed for protecting a structured polyurethane foam and anchoring the active TiO{sub 2} particles. Filled with the 3D-structured solid foam supporting TiO{sub 2} photocatalyst, the reactor could thus take advantages from the static mixer effect and from the low pressure drop resulting from the reticulated foam support. Very efficient decontamination levels towards airborne Legionella pneumophila bacteria were reached in a single-pass test mode.

  10. Strategies for the reduction of Legionella in biological treatment systems.

    Science.gov (United States)

    Nogueira, R; Utecht, K-U; Exner, M; Verstraete, W; Rosenwinkel, K-H

    A community-wide outbreak of Legionnaire's disease occurred in Warstein, Germany, in August 2013. The epidemic strain, Legionella pneumophila Serogruppe 1, was isolated from an industrial wastewater stream entering the municipal wastewater treatment plant (WWTP) in Wartein, the WWTP itself, the river Wäster and air/water samples from an industrial cooling system 3 km downstream of the WWTP. The present study investigated the effect of physical-chemical disinfection methods on the reduction of the concentration of Legionella in the biological treatment and in the treated effluent entering the river Wäster. Additionally, to gain insight into the factors that promote the growth of Legionella in biological systems, growth experiments were made with different substrates and temperatures. The dosage rates of silver micro-particles, hydrogen peroxide, chlorine dioxide and ozone and pH stress to the activated sludge were not able to decrease the number of culturable Legionella spp. in the effluent. Nevertheless, the UV treatment of secondary treated effluent reduced Legionella spp. on average by 1.6-3.4 log units. Laboratory-scale experiments and full-scale measurements suggested that the aerobic treatment of warm wastewater (30-35 °C) rich in organic nitrogen (protein) is a possible source of Legionella infection.

  11. Legionella pneumophila Carbonic Anhydrases: Underexplored Antibacterial Drug Targets

    Directory of Open Access Journals (Sweden)

    Claudiu T. Supuran

    2016-06-01

    Full Text Available Carbonic anhydrases (CAs, EC 4.2.1.1 are metalloenzymes which catalyze the hydration of carbon dioxide to bicarbonate and protons. Many pathogenic bacteria encode such enzymes belonging to the α-, β-, and/or γ-CA families. In the last decade, enzymes from some of these pathogens, including Legionella pneumophila, have been cloned and characterized in detail. These enzymes were shown to be efficient catalysts for CO2 hydration, with kcat values in the range of (3.4–8.3 × 105 s−1 and kcat/KM values of (4.7–8.5 × 107 M−1·s−1. In vitro inhibition studies with various classes of inhibitors, such as anions, sulfonamides and sulfamates, were also reported for the two β-CAs from this pathogen, LpCA1 and LpCA2. Inorganic anions were millimolar inhibitors, whereas diethyldithiocarbamate, sulfamate, sulfamide, phenylboronic acid, and phenylarsonic acid were micromolar ones. The best LpCA1 inhibitors were aminobenzolamide and structurally similar sulfonylated aromatic sulfonamides, as well as acetazolamide and ethoxzolamide (KIs in the range of 40.3–90.5 nM. The best LpCA2 inhibitors belonged to the same class of sulfonylated sulfonamides, together with acetazolamide, methazolamide, and dichlorophenamide (KIs in the range of 25.2–88.5 nM. Considering such preliminary results, the two bacterial CAs from this pathogen represent promising yet underexplored targets for obtaining antibacterials devoid of the resistance problems common to most of the clinically used antibiotics, but further studies are needed to validate them in vivo as drug targets.

  12. Thermal disinfection of hotels, hospitals, and athletic venues hot water distribution systems contaminated by Legionella species.

    Science.gov (United States)

    Mouchtouri, Varvara; Velonakis, Emmanuel; Hadjichristodoulou, Christos

    2007-11-01

    Legionella spp. (> or = 500 cfu liter(-1)) were detected in 92 of 497 water distribution systems (WDS) examined. Thermal disinfection was applied at 33 WDS. After the first and second application of the disinfection procedure, 15 (45.4%) and 3 (9%) positive for remedial actions WDS were found, respectively. Legionella pneumophila was more resistant to thermal disinfection than Legionella non-pneumophila spp. (relative risk [RR]=5.4, 95% confidence intervals [CI]=1-35). WDS of hotels with oil heater were more easily disinfected than those with electrical or solar heater (RR=0.4 95% CI=0.2-0.8). Thermal disinfection seems not to be efficient enough to eliminate legionellae, unless repeatedly applied and in combination with extended heat flushing, and faucets chlorine disinfection.

  13. Legionella species and serogroups in Malaysian water cooling towers: identification by latex agglutination and PCR-DNA sequencing of isolates.

    Science.gov (United States)

    Yong, Stacey Foong Yee; Goh, Fen-Ning; Ngeow, Yun Fong

    2010-03-01

    In this study, we investigated the distribution of Legionella species in water cooling towers located in different parts of Malaysia to obtain information that may inform public health policies for the prevention of legionellosis. A total of 20 water samples were collected from 11 cooling towers located in three different states in east, west and south Malaysia. The samples were concentrated by filtration and treated with an acid buffer before plating on to BCYE agar. Legionella viable counts in these samples ranged from 100 to 2,000 CFU ml(-1); 28 isolates from the 24 samples were examined by latex agglutination as well as 16S rRNA and rpoB PCR-DNA sequencing. These isolates were identified as Legionella pneumophila serogroup 1 (35.7%), L. pneumophila serogroup 2-14 (39%), L. pneumophila non-groupable (10.7%), L. busanensis, L. gormanii, L. anisa and L. gresilensis. L. pneumophila was clearly the predominant species at all sampling sites. Repeat sampling from the same cooling tower and testing different colonies from the same water sample showed concurrent colonization by different serogroups and different species of Legionella in some of the cooling towers.

  14. Effect of UV irradiation (253.7 nm) on free Legionella and Legionella associated with its amoebae hosts.

    Science.gov (United States)

    Cervero-Aragó, Sílvia; Sommer, Regina; Araujo, Rosa M

    2014-12-15

    Water systems are the primary reservoir for Legionella spp., where the bacteria live in association with other microorganisms, such as free-living amoebae. A wide range of disinfection treatments have been studied to control and prevent Legionella colonization but few of them were performed considering its relation with protozoa. In this study, the effectiveness of UV irradiation (253.7 nm) using low-pressure lamps was investigated as a disinfection method for Legionella and amoebae under controlled laboratory conditions. UV treatments were applied to 5 strains of Legionella spp., 4 strains of free-living amoeba of the genera Acanthamoeba and Vermamoeba, treating separately trophozoites and cysts, and to two different co-cultures of Legionella pneumophila with the Acanthamoeba strains. No significant differences in the UV inactivation behavior were observed among Legionella strains tested which were 3 logs reduced for fluences around 45 J/m(2). UV irradiation was less effective against free-living amoebae; which in some cases required up to 990 J/m(2) to obtain the same population reduction. UV treatment was more effective against trophozoites compared to cysts; moreover, inactivation patterns were clearly different between the genus Acanthamoeba and Vermamoeba. For the first time data about Vermamoeba vermiformis UV inactivation has been reported in a study. Finally, the results showed that the association of L. pneumophila with free-living amoebae decreases the effectiveness of UV irradiation against the bacteria in a range of 1.5-2 fold. That fact demonstrates that the relations established between different microorganisms in the water systems can modify the effectiveness of the UV treatments applied. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Comparative and functional genomics of Legionella identified eukaryotic like proteins as key players in host-pathogen interactions

    Directory of Open Access Journals (Sweden)

    Laura eGomez-Valero

    2011-10-01

    Full Text Available Although best known for its ability to cause severe pneumonia in people whose immune defenses are weakened, Legionella pneumophila and Legionella longbeachae are two species of a large genus of bacteria that are ubiquitous in nature, where they parasitize protozoa. Adaptation to the host environment and exploitation of host cell functions are critical for the success of these intracellular pathogens. The establishment and publication of the complete genome sequences of L. pneumophila and L. longbeachae isolates paved the way for major breakthroughs in understanding the biology of these organisms. In this review we present the knowledge gained from the analyses and comparison of the complete genome sequences of different L. pneumophila and L. longbeachae strains. Emphasis is given on putative virulence and Legionella life cycle related functions, such as the identification of an extended array of eukaryotic-like proteins, many of which have been shown to modulate host cell functions to the pathogen's advantage. Surprisingly, many of the eukaryotic domain proteins identified in L. pneumophila as well as many substrates of the Dot/Icm type IV secretion system essential for intracellular replication are different between these two species, although they cause the same disease. Finally, evolutionary aspects regarding the eukaryotic like proteins in Legionella are discussed.

  16. Short-Term and Long-Term Survival and Virulence of Legionella pneumophila in the Defined Freshwater Medium Fraquil.

    Directory of Open Access Journals (Sweden)

    Nilmini Mendis

    Full Text Available Legionella pneumophila (Lp is the etiological agent responsible for Legionnaires' disease, a potentially fatal pulmonary infection. Lp lives and multiplies inside protozoa in a variety of natural and man-made water systems prior to human infection. Fraquil, a defined freshwater medium, was used as a highly reproducible medium to study the behaviour of Lp in water. Adopting a reductionist approach, Fraquil was used to study the impact of temperature, pH and trace metal levels on the survival and subsequent intracellular multiplication of Lp in Acanthamoeba castellanii, a freshwater protozoan and a natural host of Legionella. We show that temperature has a significant impact on the short- and long-term survival of Lp, but that the bacterium retains intracellular multiplication potential for over six months in Fraquil. Moreover, incubation in Fraquil at pH 4.0 resulted in a rapid decline in colony forming units, but was not detrimental to intracellular multiplication. In contrast, variations in trace metal concentrations had no impact on either survival or intracellular multiplication in amoeba. Our data show that Lp is a resilient bacterium in the water environment, remaining infectious to host cells after six months under the nutrient-deprived conditions of Fraquil.

  17. Comparison between standard culture and peptide nucleic acid 16S rRNA hybridization quantification to study the influence of physico-chemical parameters on Legionella pneumophila survival in drinking water biofilms.

    Science.gov (United States)

    Gião, M S; Wilks, S A; Azevedo, N F; Vieira, M J; Keevil, C W

    2009-01-01

    Legionella pneumophila is a waterborne pathogen that is mainly transmitted by the inhalation of contaminated aerosols. In this article, the influence of several physico-chemical parameters relating to the supply of potable water was studied using a L. pneumophila peptide nucleic acid (PNA) specific probe to quantify total L. pneumophila in addition to standard culture methods. A two-stage chemostat was used to form the heterotrophic biofilms, with biofilm generating vessels fed with naturally occurring L. pneumophila. The substratum was the commonly used potable water pipe material, uPVC. It proved impossible to recover cultivable L. pneumophila due to overgrowth by other microorganisms and/or the loss of cultivability of this pathogen. Nevertheless, results obtained for total L. pneumophila cells in biofilms using a specific PNA probe showed that for the two temperatures studied (15 and 20 degrees C), there were no significant differences when shear stress was increased. However, when a source of carbon was added there was a significant increase in numbers at 20 degrees C. A comparison of the two temperatures showed that at 15 degrees C, the total cell numbers for L. pneumophila were generally higher compared with the total microbial flora, suggesting that lower temperatures support the inclusion of L. pneumophila in drinking water biofilms. The work reported in this article suggests that standard culture methods are not accurate for the evaluation of water quality in terms of L. pneumophila. This raises public health concerns since culture methods are still considered to be the gold standard for assessing the presence of this opportunistic pathogen in water.

  18. Legionella risk assessment in cruise ships and ferries.

    Science.gov (United States)

    Laganà, Pasqualina; Gambuzza, Maria Elsa; Delia, Santi

    2017-06-12

    Introduction. The increasing development of marine traffic has led to a rise in the incidence of legionellosis among travellers. It occurs in similar environments, especially closed and crowded, and aboard ships Legionella survives and multiplies easily in water pipes, spreading into the environment through air conditioning systems and water distribution points. Although in recent years in the construction of cruise ships preventive measures aimed at curbing the proliferation of Legionella (design, materials, focus on the operation and maintenance of the water system), have been taken account, little or no attention has been paid to small ships which, in many cases, are old and not well maintained. Objective. The aim of the study was to evaluate the frequency and severity of Legionella contamination in ferries and cruise ships in order to adopt more specific control measures. Materials and method. A prevalence study was carried out on 10 ferries and 6 cruise ships docking or in transit across the port of Messina (Sicily, Italy). Water and air samples collected from many critical points were tested for qualitative and quantitative identification of Legionella. Results and conclusions. Legionella pneumophila sg 1 was isolated from the samples of shower and tap water in 7 (70%) of the 10 ferries examined, and in 3 (33%) of the 6 cruise ships examined, and L. pneumophila sg 2-14 in 8 (80%) and 1 (16.7%) of these ships, respectively. No Legionella contamination was found in whirlpool baths, air and ice samples. In conclusion, the data obtained confirm higher levels of Legionella contamination in local ferries and cruise ships, underlining the need to adopt corrective actions more specific for these smaller vessels.

  19. Legionella bacteria in combustion air humidifiers; Legionella i luftuppfuktare foer foerbraenningsluft

    Energy Technology Data Exchange (ETDEWEB)

    Jeppesen, Jessica; Hansson, Helen; Cederfeldt, Ola; Axby, Fredrik

    2007-10-15

    had positive test results for legionella, three of them contained Legionella pneumophila serogroup 1. In the second test round, two of the plants had positive test results but only one of them was verified to L. pneumophila sg 1. Both the fuel gas analyses showed negative results for legionella bacteria and the level of heterotrophic bacteria was low or nonexistent. In this report the occurrence of legionella bacteria in combustion air humidifiers has mainly been treated as a working environmental risk. A risk assessment for the plant with the highest amount of legionella bacteria shows that the growth of legionella primary should be minimized/eliminated. As a compliment, personal safety devices such as respiratory protection should be used during revision work in water tanks or while cleaning the water system, i.e. when the risk for water aerosols is greater than during normal operation of the plant. The employer is responsible to inform all personal who might become infected with legionella. There should also be routines for reporting as well as routines for both proactive and reactive measures. From the test results the conclusion that legionella bacteria occur in combustion air humidifiers can be drawn. In addition legionella bacteria can occur in all three studied types of air humidifiers; rotating-, lamella- and scrubber air humidifiers. It is difficult to predict how great a risk it is that legionella bacteria will occur in the different types of air humidifiers. The risk of legionella bacteria transferring from the water systems to outgoing fuel gas varies in the different types of air humidifiers. It is obvious that the risk of transferring legionella bacteria to the fuel gas is greater in rotating air humidifiers and in lamella air humidifiers where both fuel gas and air is washed with water from the same water system. There is also a risk of transferring legionella bacteria to fuel gas in scrubber air humidifiers where the air humidifier and the condenser

  20. Aminoacyl-tRNA-charged eukaryotic elongation factor 1A is a bona fide substrate for Legionelle pneumophila effector glucosyltransferases

    DEFF Research Database (Denmark)

    Tzivelekidis, Tina; Jank, Thomas; Pohl, Corinna

    2011-01-01

    Legionella pneumophila, which is the causative organism of Legionnaires disease, translocates numerous effector proteins into the host cell cytosol by a type IV secretion system during infection. Among the most potent effector proteins of Legionella are glucosyltransferases (Lgt’s), which...

  1. Detection of airborne Legionella while showering using liquid impingement and fluorescent in situ hybridization (FISH).

    Science.gov (United States)

    Deloge-Abarkan, Magali; Ha, Thi-Lan; Robine, Enric; Zmirou-Navier, Denis; Mathieu, Laurence

    2007-01-01

    Aerosols of water contaminated with Legionella bacteria constitute the only mode of exposure for humans. However, the prevention strategy against this pathogenic bacteria risk is managed through the survey of water contamination. No relationship linked the Legionella bacteria water concentration and their airborne abundance. Therefore, new approaches in the field of the metrological aspects of Legionella bioaerosols are required. This study was aimed at testing the main principles for bioaerosol collection (solid impaction, liquid impingement and filtration) and the in situ hybridization (FISH) method, both in laboratory and field assays, with the intention of applying such methodologies for airborne Legionella bacteria detection while showering. An aerosolization chamber was developed to generate controlled and reproducible L. pneumophila aerosols. This tool allowed the identification of the liquid impingement method as the most appropriate one for collecting airborne Legionella bacteria. The culturable fraction of airborne L. pneumophila recovered with the liquid impingement principle was 4 and 700 times higher compared to the impaction and filtration techniques, respectively. Moreover, the concentrations of airborne L. pneumophila in the impinger fluid were on average 7.0 x 10(5) FISH-cells m(-3) air with the fluorescent in situ hybridization (FISH) method versus 9.0 x 10(4) CFU m(-3) air with the culture method. These results, recorded under well-controlled conditions, were confirmed during the field experiments performed on aerosols generated by hot water showers in health institutions. This new approach may provide a more accurate characterization of aerobiocontamination by Legionella bacteria.

  2. The htpAB operon of Legionella pneumophila cannot be deleted in the presence of the groE chaperonin operon of Escherichia coli.

    Science.gov (United States)

    Nasrallah, Gheyath K; Gagnon, Elizabeth; Orton, Dennis J; Garduño, Rafael A

    2011-11-01

    HtpB, the chaperonin of the intracellular bacterial pathogen Legionella pneumophila , displays several virulence-related functions in vitro. To confirm HtpB's role in vivo, host infections with an htpB deletion mutant would be required. However, we previously reported that the htpAB operon (encoding co-chaperonin and chaperonin) is essential. We attempted here to delete htpAB in a L. pneumophila strain carrying the groE operon (encoding the Escherichia coli co-chaperonin and chaperonin). The groE operon was inserted into the chromosome of L. pneumophila Lp02, and then allelic replacement of htpAB with a gentamicin resistance cassette was attempted. Although numerous potential postallelic replacement transformants showed a correct selection phenotype, we still detected htpAB by PCR and full-size HtpB by immunoblot. Southern blot and PCR analysis indicated that the gentamicin resistance cassette had apparently integrated in a duplicated htpAB region. However, we showed by Southern blot that strain Lp02, and the Lp02 derivative carrying the groE operon, have only one copy of htpAB. These results confirmed that the htpAB operon cannot be deleted, not even in the presence of the groE operon, and suggested that attempts to delete htpAB under strong phenotypic selection result in aberrant genetic recombinations that could involve duplication of the htpAB locus.

  3. A new Legionella species, Legionella feeleii species nova, causes Pontiac fever in an automobile plant.

    Science.gov (United States)

    Herwaldt, L A; Gorman, G W; McGrath, T; Toma, S; Brake, B; Hightower, A W; Jones, J; Reingold, A L; Boxer, P A; Tang, P W

    1984-03-01

    From 15 to 21 August 1981, Pontiac fever affected 317 automobile assembly plant workers. Results of serologic tests were negative for Mycoplasma, Chlamydia, respiratory tract viruses, and previously described legionellae. A gram-negative, rod-shaped organism (WO-44C) that did not grow on blood agar, required L-cysteine for growth, and contained large amounts of branched-chain fatty acids was isolated from a water-based coolant. The organism did not react with antisera against other legionellae, and on DNA hybridization the organism was less than 10% related to other Legionella species. Geometric mean titers found by indirect fluorescent antibody testing to WO-44C were significantly higher in ill employees than in controls (p = 0.0001). Attack rates by department decreased linearly with the department's distance from the implicated coolant system. The etiologic agent apparently was a new Legionella species; we propose the name Legionella feeleii species nova (AATC 35072). This is the first outbreak of nonpneumonic legionellosis in which the etiologic agent is not L. pneumophila, serogroup 1.

  4. Rainfall is a risk factor for sporadic cases of Legionella pneumophila pneumonia.

    Directory of Open Access Journals (Sweden)

    Carolina Garcia-Vidal

    Full Text Available It is not known whether rainfall increases the risk of sporadic cases of Legionella pneumonia. We sought to test this hypothesis in a prospective observational cohort study of non-immunosuppressed adults hospitalized for community-acquired pneumonia (1995-2011. Cases with Legionella pneumonia were compared with those with non-Legionella pneumonia. Using daily rainfall data obtained from the regional meteorological service we examined patterns of rainfall over the days prior to admission in each study group. Of 4168 patients, 231 (5.5% had Legionella pneumonia. The diagnosis was based on one or more of the following: sputum (41 cases, antigenuria (206 and serology (98. Daily rainfall average was 0.556 liters/m(2 in the Legionella pneumonia group vs. 0.328 liters/m(2 for non-Legionella pneumonia cases (p = 0.04. A ROC curve was plotted to compare the incidence of Legionella pneumonia and the weighted median rainfall. The cut-off point was 0.42 (AUC 0.54. Patients who were admitted to hospital with a prior weighted median rainfall higher than 0.42 were more likely to have Legionella pneumonia (OR 1.35; 95% CI 1.02-1.78; p = .03. Spearman Rho correlations revealed a relationship between Legionella pneumonia and rainfall average during each two-week reporting period (0.14; p = 0.003. No relationship was found between rainfall average and non-Legionella pneumonia cases (-0.06; p = 0.24. As a conclusion, rainfall is a significant risk factor for sporadic Legionella pneumonia. Physicians should carefully consider Legionella pneumonia when selecting diagnostic tests and antimicrobial therapy for patients presenting with CAP after periods of rainfall.

  5. Multiple regression as a preventive tool for determining the risk of Legionella spp.

    Directory of Open Access Journals (Sweden)

    Enrique Gea-Izquierdo

    2012-04-01

    Full Text Available To determine the interrelationship between health & hygiene conditions for prevention of legionellosis, the compositionof materials used in water distribution systems, the water origin and Legionella pneumophila risk. Material and methods. Include adescriptive study and multiple regression analysis on a sample of golf course sprinkler irrigation systems (n=31 pertaining to hotelslocated on the Costa del Sol (Malaga, Spain. The study was carried out in 2009. Results. Presented a significant lineal relation, withall the independent variables contributing significantly (p<0.05 to the model’s fit. The relationship between water type and the risk ofLegionella, as well as the material composition and the latter, is lineal and positive. In contrast, the relationship between health-hygieneconditions and Legionella risk is lineal and negative. Conclusion. The characterization of Legionella pneumophila concentration, asdefined by the risk in water and through use of the predictive method, can contribute to the consideration of new influence variables inthe development of the agent, resulting in improved control and prevention of the disease.

  6. Viable Legionella pneumophila bacteria in natural soil and rainwater puddles

    NARCIS (Netherlands)

    van Heijnsbergen, E.; de Roda Husman, A. M.; Lodder, W. J.; Bouwknegt, M.; Docters van Leeuwen, A. E.; Bruin, J. P.; Euser, S. M.; den Boer, J. W.; Schalk, J. A C

    Aims: For the majority of sporadic Legionnaires' disease cases the source of infection remains unknown. Infection may possible result from exposure to Legionella bacteria in sources that are not yet considered in outbreak investigations. Therefore, potential sources of pathogenic Legionella

  7. Effects of metals on Legionella pneumophila growth in drinking water plumbing systems

    Energy Technology Data Exchange (ETDEWEB)

    States, S.J.; Conley, L.F.; Ceraso, M.; Stephenson, T.E.; Wolford, R.S.; Wadowsky, R.M.; McNamara, A.M.; Yee, R.B.

    1985-11-01

    Water samples were collected from hospital and institutional hot-water tanks known to have supported L. pneumophila and were analyzed for 23 chemical parameters. The chemical environment of these tanks was found to vary extensively, with the concentrations of certain metals reaching relatively high levels due to corrosion. The effect of various chemical conditions on L. pneumophila growth was then examined by observing its multiplication in a series of tap water samples artificially supplemented with various concentrations of metals. Additionally, growth of L. pneumophila was examined in a more natural setting by monitoring its multiplication in the chemically analyzed hot-water tank samples after sterilization and reinoculation with L. pneumophila. L. Pneumophila and associated microbiota used in these experiments were obtained from a hot-water tank. These strains were maintained in tap water and had never been passaged on agar. The results of the growth studies indicate that although elevated concentrations of a number of metals are toxic, lower levels of certain metals such as iron, zinc, and potassium enhance growth of naturally occurring L. pneumophila. Parallel observations on accompanying non-Legionellaceae bacteria failed to show the same relationship. These findings suggest that metal plumbing components and associated corrosion products are important factors in the survival and growth of L. pneumophila in plumbing systems and may also be important in related habitats such as cooling towers and air-conditioning systems. 1 figure, 2 tables.

  8. Presence of Legionella spp. in Hot Water Networks of Different Italian Residential Buildings: A Three-Year Survey.

    Science.gov (United States)

    Totaro, Michele; Valentini, Paola; Costa, Anna Laura; Frendo, Lorenzo; Cappello, Alessia; Casini, Beatrice; Miccoli, Mario; Privitera, Gaetano; Baggiani, Angelo

    2017-10-26

    Although the European reports highlight an increase in community-acquired Legionnaires' disease cases, the risk of Legionella spp. in private houses is underestimated. In Pisa (Italy) we performed a three-year survey on Legionella presence in 121 buildings with an independent hot water production (IB); 64 buildings with a central hot water production (CB); and 35 buildings with a solar thermal system for hot water production (TB). From all the 220 buildings Legionella spp. was researched in two hot water samples collected either at the recirculation point or on the first floor and on the last floor, while the potable water quality was analysed in three cold water samples collected at the inlet from the aqueduct network, at the exit from the autoclave, and at the most remote tap. Legionella pneumophila sg1, Legionella pneumophila sg2-16, and non- pneumophila Legionella species were detected in 26% of the hot water networks, mostly in CB and TB. In these buildings we detected correlations between the presence of Legionella and the total chlorine concentration decrease and/or the increase of the temperature. Cold water resulted free from microbiological hazards, with the exception of Serratia liquefaciens and Enterobacter cloacae isolated at the exit from two different autoclaves. We observed an increase in total microbial counts at 22 °C and 37 °C between the samples collected at the most remote taps compared to the ones collected at the inlet from the aqueduct. The study highlights a condition of potential risk for susceptible categories of population and supports the need for measures of risk assessment and control.

  9. Legionella species diversity and dynamics from surface reservoir to tap water: from cold adaptation to thermophily.

    Science.gov (United States)

    Lesnik, René; Brettar, Ingrid; Höfle, Manfred G

    2016-05-01

    Water samples of the Drinking Water Supply System (DWSS) of the city of Braunschweig were analysed for its Legionella species composition using genus-specific PCR amplicons and single-strand conformation polymorphism (SSCP) fingerprint analyses based on 16S rRNA genes. These analyses comprised the whole supply chain including raw water, treatment process and large-scale storage, and a seasonal study of finished drinking water sampled monthly from cold and hot tap water. Treatment of raw water had a major impact on Legionella species by reducing their diversity and abundances. The Legionella species composition of the tap water was highly distinct from that of both source waters. In cold water, 8-14 different phylotypes of Legionella (PTLs) were observed per sample with relative abundances ranging from >1% to 53%. In hot water, L. pneumophila was present during all seasons at high relative abundances (8-40%) accompanied by 5-14 other PTLs of which 6 PTLs were in common with cold water. This thermophilic Legionella community, including L. pneumophila, was able to grow in the hot water above 50 °C. Such thermophilic Legionella populations are of general relevance for drinking water management and public health, but also for the ecology and evolution of the genus Legionella.

  10. Nosocomial infection with Legionella pneumophila serogroup 1 and 8 in a neonate.

    Science.gov (United States)

    Aubert, G; Bornstein, N; Rayet, I; Pozzetto, B; Lenormand, P H

    1990-01-01

    A case of pneumonia related to 2 serogroups (1 and 8) of Legionella pneumophila (Lp) in a 10-day-old boy is described together with the epidemiological survey in the maternity ward which made it possible to establish its nosocomial origin. Rodshaped bacteria reacting with an Lp genus-specific monoclonal antibody and serogroup 1 and 8 polyclonal sera were detected in bronchoalveolar lavages (BAL) collected on day 13. Serogroups 1 and 8 were recovered from cultures of BAL collected on days 12 and 13. Fourfold or more antibody rises to serogroups 1, 5, 8 and 10 of Lp were observed in sequential serum specimens. Water samples collected from the tank and mixer of the maternity ward grew serogroups 1 and 8 of Lp. Serogroup 1 was detected in large amounts in water samples taken at several points of the hot water supply system and from the oxygen nebulizers and the feeding-bottle heater. Analysis of the Lp serogroup 1 strains isolated from the water by subgroup-specific monoclonal antibodies revealed the presence of 4 different subgroups, one of which was identical to the Lp 1 subgroup isolated from the neonate's BAL. This latter subgroup, reactive with McKinney monoclonal antibody Mab 2, has been described as highly virulent. No other case of legionellosis was recorded in the maternity ward.

  11. Evaluation of Legionella real-time PCR against traditional culture for routine and public health testing of water samples.

    Science.gov (United States)

    Collins, S; Stevenson, D; Walker, J; Bennett, A

    2017-06-01

    To evaluate the usefulness of Legionella qPCR alongside traditional culture for enumeration of Legionella from water samples as part of both routine and public health investigation testing. Routine water samples (n = 2002) and samples from public health investigations (n = 215) were analysed by culture and qPCR for Legionella spp., Legionella pneumophila and L. pneumophila sg-1. A negative qPCR result was highly predictive of a negative culture result for all water systems (negative predictive values, NPV from 97·4 to 100%). Positive predictive values (PPV) were lower (0-50%). Results for qPCR were generally larger than culture with average log 10 differences of 1·1 for Legionella spp. and 1·2 for L. pneumophila. Alert and action levels of 1000 and 10 000 GU per litre, respectively, are proposed for Legionella qPCR for hot and cold water systems (HCWS). The use of qPCR significantly reduced the time to results for public health investigations by rapidly identifying potential sources and ruling out others, thus enabling a more rapid and efficient response. The high NPV of qPCR supports its use to rapidly screen out negative samples without culture. Alert and action levels for Legionella qPCR for HCWS are proposed. Quantitative PCR will be a valuable tool for both routine and public health testing. This study generated comparative data of >2000 water samples by qPCR and culture. Action and alert levels have been recommended that could enable duty holders to interpret qPCR results to facilitate timely Legionella control and public health protection. © 2017 Crown copyright. Journal of Applied Microbiology © 2017 The Society for Applied Microbiology.

  12. Simultaneous detection of Legionella species and L. anisa, L. bozemanii, L. longbeachae and L. micdadei using conserved primers and multiple probes in a multiplex real-time PCR assay.

    Science.gov (United States)

    Cross, Kristen E; Mercante, Jeffrey W; Benitez, Alvaro J; Brown, Ellen W; Diaz, Maureen H; Winchell, Jonas M

    2016-07-01

    Legionnaires' disease is a severe respiratory disease that is estimated to cause between 8,000 and 18,000 hospitalizations each year, though the exact burden is unknown due to under-utilization of diagnostic testing. Although Legionella pneumophila is the most common species detected in clinical cases (80-90%), other species have also been reported to cause disease. However, little is known about Legionnaires' disease caused by these non-pneumophila species. We designed a multiplex real-time PCR assay for detection of all Legionella spp. and simultaneous specific identification of four clinically-relevant Legionella species, L. anisa, L. bozemanii, L. longbeachae, and L. micdadei, using 5'-hydrolysis probe real-time PCR. The analytical sensitivity for detection of nucleic acid from each target species was ≤50fg per reaction. We demonstrated the utility of this assay in spiked human sputum specimens. This assay could serve as a tool for understanding the scope and impact of non-pneumophila Legionella species in human disease. Published by Elsevier Inc.

  13. Legionella longbeachae detected in an industrial cooling tower linked to a legionellosis outbreak, New Zealand, 2015; possible waterborne transmission?

    Science.gov (United States)

    Thornley, C N; Harte, D J; Weir, R P; Allen, L J; Knightbridge, K J; Wood, P R T

    2017-08-01

    A legionellosis outbreak at an industrial site was investigated to identify and control the source. Cases were identified from disease notifications, workplace illness records, and from clinicians. Cases were interviewed for symptoms and risk factors and tested for legionellosis. Implicated environmental sources were sampled and tested for legionella. We identified six cases with Legionnaires' disease and seven with Pontiac fever; all had been exposed to aerosols from the cooling towers on the site. Nine cases had evidence of infection with either Legionella pneumophila serogroup (sg) 1 or Legionella longbeachae sg1; these organisms were also isolated from the cooling towers. There was 100% DNA sequence homology between cooling tower and clinical isolates of L. pneumophila sg1 using sequence-based typing analysis; no clinical L. longbeachae isolates were available to compare with environmental isolates. Routine monitoring of the towers prior to the outbreak failed to detect any legionella. Data from this outbreak indicate that L. pneumophila sg1 transmission occurred from the cooling towers; in addition, L. longbeachae transmission was suggested but remains unproven. L. longbeachae detection in cooling towers has not been previously reported in association with legionellosis outbreaks. Waterborne transmission should not be discounted in investigations for the source of L. longbeachae infection.

  14. Genome Analysis of Legionella pneumophila Strains Using a Mixed-Genome Microarray

    NARCIS (Netherlands)

    Euser, S.M.; Nagelkerke, N.J.; Schuren, F.; Jansen, R.; Boer, J.W. den

    2012-01-01

    Background: Legionella, the causative agent for Legionnaires' disease, is ubiquitous in both natural and man-made aquatic environments. The distribution of Legionella genotypes within clinical strains is significantly different from that found in environmental strains. Developing novel genotypic

  15. Occurrence and Control of Legionella in Recycled Water Systems

    Science.gov (United States)

    Jjemba, Patrick K.; Johnson, William; Bukhari, Zia; LeChevallier, Mark W.

    2015-01-01

    Legionella pneumophila is on the United States Environmental Protection Agency (USEPA) Candidate Contaminant list (CCL) as an important pathogen. It is commonly encountered in recycled water and is typically associated with amoeba, notably Naegleria fowleri (also on the CCL) and Acanthamoeba sp. No legionellosis outbreak has been linked to recycled water and it is important for the industry to proactively keep things that way. A review was conducted examine the occurrence of Legionella and its protozoa symbionts in recycled water with the aim of developing a risk management strategy. The review considered the intricate ecological relationships between Legionella and protozoa, methods for detecting both symbionts, and the efficacy of various disinfectants. PMID:26140674

  16. Survey of Legionella pneumophila among pneumonia patients at ...

    African Journals Online (AJOL)

    Objective: To determine the occurrence of L. pneumophila among pneumonia patients at Kenyatta National Hospital and any association with possible risk factors. Design: A cross- sectional descriptive study. Setting: The study was conducted from March to June 2007, at the medical ward of Kenyatta National Hospital.

  17. Legionella prevalence and risk of legionellosis in Japanese households.

    Science.gov (United States)

    Kuroki, T; Watanabe, Y; Teranishi, H; Izumiyama, S; Amemura-Maekawa, J; Kura, F

    2017-05-01

    This study determined the occurrence of legionellae in private houses for which there were no available data on aquatic environments other than the water supply system. From June 2013 to November 2014, we collected 138 water and 90 swab samples from aquatic environments in 19 houses. Legionella DNA was detected via a loop-mediated isothermal amplification assay in 66 (47·8%) water and 17 (18·9%) swab samples. High Legionella DNA detection rates were observed in water samples from washing machines and aquariums. Legionella spp. was isolated from 9 (6·5%) water and 3 (3·3%) swab samples. Legionella pneumophila SG 1 was detected from the outlet water of a bathtub spout and a bath sponge. Use of amoebic co-culture effectively increased legionellae and Legionella DNA detection rates from all sample types. A logistic regression analysis revealed that the heterotrophic plate count was significantly related to Legionella contamination. Our findings indicate that there is a risk of legionellosis from exposure to Legionella spp. in a variety of aquatic environments in residential houses. Control measures for legionellae in houses should include frequent cleaning and disinfecting to reduce heterotrophic bacteria in water and, where possible, preventing aerosolization from aquatic environments.

  18. Legionella prevalence and risk of legionellosis in Hungarian hospitals.

    Science.gov (United States)

    Barna, Zsófia; Kádár, Mihály; Kálmán, Emese; Róka, Eszter; Szax, Anita Sch; Vargha, Márta

    2015-12-01

    Nosocomial legionellosis is a growing concern worldwide. In Hungary, about 20% of the reported cases are health-care associated, but in the absence of legal regulation, environmental monitoring of Legionella is not routinely performed in hospitals. In the present study, 23 hospitals were investigated. The hot water distribution system was colonized by Legionella in over 90%; counts generally exceeded the public health limit value. Hot water temperature was critically low in all systems (Legionella prevalence (OR = 28.0, 27.3, 27.7, respectively). Risk management interventions (including thermal or chemical disinfection) were only efficient if the system operation was optimized. Though the risk factors were similar, in those hospitals where nosocomial legionellosis was reported, Legionella counts and the proportion of L. pneumophila sg 1 isolates were significantly higher. The results of environmental prevalence of legionellae in hospitals suggest that the incidence of nosocomial legionellosis is likely to be underreported. The observed colonization rates call for the introduction of a mandatory environmental monitoring scheme.

  19. Chest X-ray in Legionella pneumonia (Legionnaires' disease)

    Energy Technology Data Exchange (ETDEWEB)

    Meenhorst, P.L.; Mulder, J.D.

    1983-08-01

    The authors compared the radiological evolution and patterns of Legionella pneumophila pneumonia in 13 immunocompromised and 13 non-immunocompromised patients. Apart from the occurrence of cavitation and the longer time it took before consolidations cleared in immunocompromised patients no differences were found between the two groups of patients.

  20. The chest X-ray in Legionella pneumonia (Legionnaires' disease)

    International Nuclear Information System (INIS)

    Meenhorst, P.L.; Mulder, J.D.

    1983-01-01

    The authors compared the radiological evolution and patterns of Legionella pneumophila pneumonia in 13 immunocompromised and 13 non-immunocompromised patients. Apart from the occurrence of cavitation and the longer time it took before consolidations cleared in immunocompromised patients no differences were found between the two groups of patients. (orig.)

  1. Structural basis for Rab1 de-AMPylation by the Legionella pneumophila effector SidD.

    Directory of Open Access Journals (Sweden)

    Yang Chen

    Full Text Available The covalent attachment of adenosine monophosphate (AMP to proteins, a process called AMPylation (adenylylation, has recently emerged as a novel theme in microbial pathogenesis. Although several AMPylating enzymes have been characterized, the only known virulence protein with de-AMPylation activity is SidD from the human pathogen Legionella pneumophila. SidD de-AMPylates mammalian Rab1, a small GTPase involved in secretory vesicle transport, thereby targeting the host protein for inactivation. The molecular mechanisms underlying Rab1 recognition and de-AMPylation by SidD are unclear. Here, we report the crystal structure of the catalytic region of SidD at 1.6 Å resolution. The structure reveals a phosphatase-like fold with additional structural elements not present in generic PP2C-type phosphatases. The catalytic pocket contains a binuclear metal-binding site characteristic of hydrolytic metalloenzymes, with strong dependency on magnesium ions. Subsequent docking and molecular dynamics simulations between SidD and Rab1 revealed the interface contacts and the energetic contribution of key residues to the interaction. In conjunction with an extensive structure-based mutational analysis, we provide in vivo and in vitro evidence for a remarkable adaptation of SidD to its host cell target Rab1 which explains how this effector confers specificity to the reaction it catalyses.

  2. Surveillance of parasitic Legionella in surface waters by using immunomagnetic separation and amoebae enrichment.

    Science.gov (United States)

    Hsu, Tsui-Kang; Wu, Shu-Fen; Hsu, Bing-Mu; Kao, Po-Min; Tao, Chi-Wei; Shen, Shu-Min; Ji, Wen-Tsai; Huang, Wen-Chien; Fan, Cheng-Wei

    2015-01-01

    Free-living amoebae (FLA) are potential reservoirs of Legionella in aquatic environments. However, the parasitic relationship between various Legionella and amoebae remains unclear. In this study, surface water samples were gathered from two rivers for evaluating parasitic Legionella. Warmer water temperature is critical to the existence of Legionella. This result suggests that amoebae may be helpful in maintaining Legionella in natural environments because warmer temperatures could enhance parasitisation of Legionella in amoebae. We next used immunomagnetic separation (IMS) to identify extracellular Legionella and remove most free Legionella before detecting the parasitic ones in selectively enriched amoebae. Legionella pneumophila was detected in all the approaches, confirming that the pathogen is a facultative amoebae parasite. By contrast, two obligate amoebae parasites, Legionella-like amoebal pathogens (LLAPs) 8 and 9, were detected only in enriched amoebae. However, several uncultured Legionella were detected only in the extracellular samples. Because the presence of potential hosts, namely Vermamoeba vermiformis, Acanthamoeba spp. and Naegleria gruberi, was confirmed in the samples that contained intracellular Legionella, uncultured Legionella may survive independently of amoebae. Immunomagnetic separation and amoebae enrichment may have referential value for detecting parasitic Legionella in surface waters.

  3. Antibiotic susceptibility of Legionella strains isolated from public water sources in Macau and Guangzhou.

    Science.gov (United States)

    Xiong, Lina; Yan, He; Shi, Lei; Mo, Ziyao

    2016-12-01

    The purpose of this study was to investigate the susceptibility of waterborne strains of Legionella to eight antimicrobials commonly used in legionellosis therapy. The minimum inhibitory concentrations (MICs) of 66 environmental Legionella strains, isolated from fountains and cooling towers of public facilities (hotels, schools, and shopping malls) in Macau and Guangzhou, were tested using the microdilution method in buffered yeast extract broth. The MIC 50 /MIC 90 values for erythromycin, cefotaxime (CTX), doxycycline (DOC), minocycline (MIN), azithromycin, ciprofloxacin, levofloxacin (LEV), and moxifloxacin were 0.125/0.5 mg/L, 4/8 mg/L, 8/16 mg/L, 4/8 mg/L, 0.125/0.5 mg/L, 0.031/0.031 mg/L, 0.031/0.031 mg/L, and 0.031/0.062 mg/L, respectively. Legionella isolates were inhibited by either low concentrations of macrolides and fluoroquinolones, or high concentrations of CTX and tetracycline drugs. LEV was the most effective drug against different Legionella species and serogroups of L. pneumophila isolates. The latter were inhibited in decreasing order by MIN > CTX >DOC, while non-L. pneumophila isolates were inhibited by CTX> MIN >DOC. In this study, we evaluated drug resistance of pathogenic bacteria from the environment. This may help predict the emergence of drug resistance, improve patient outcomes, and reduce hospitalization costs.

  4. Surface display of a massively variable lipoprotein by a Legionella diversity-generating retroelement.

    Science.gov (United States)

    Arambula, Diego; Wong, Wenge; Medhekar, Bob A; Guo, Huatao; Gingery, Mari; Czornyj, Elizabeth; Liu, Minghsun; Dey, Sanghamitra; Ghosh, Partho; Miller, Jeff F

    2013-05-14

    Diversity-generating retroelements (DGRs) are a unique family of retroelements that confer selective advantages to their hosts by facilitating localized DNA sequence evolution through a specialized error-prone reverse transcription process. We characterized a DGR in Legionella pneumophila, an opportunistic human pathogen that causes Legionnaires disease. The L. pneumophila DGR is found within a horizontally acquired genomic island, and it can theoretically generate 10(26) unique nucleotide sequences in its target gene, legionella determinent target A (ldtA), creating a repertoire of 10(19) distinct proteins. Expression of the L. pneumophila DGR resulted in transfer of DNA sequence information from a template repeat to a variable repeat (VR) accompanied by adenine-specific mutagenesis of progeny VRs at the 3'end of ldtA. ldtA encodes a twin-arginine translocated lipoprotein that is anchored in the outer leaflet of the outer membrane, with its C-terminal variable region surface exposed. Related DGRs were identified in L. pneumophila clinical isolates that encode unique target proteins with homologous VRs, demonstrating the adaptability of DGR components. This work characterizes a DGR that diversifies a bacterial protein and confirms the hypothesis that DGR-mediated mutagenic homing occurs through a conserved mechanism. Comparative bioinformatics predicts that surface display of massively variable proteins is a defining feature of a subset of bacterial DGRs.

  5. Inactivation kinetics and efficiencies of UV-LEDs against Pseudomonas aeruginosa, Legionella pneumophila, and surrogate microorganisms.

    Science.gov (United States)

    Rattanakul, Surapong; Oguma, Kumiko

    2018-03-01

    To demonstrate the effectiveness of UV light-emitting diodes (UV-LEDs) to disinfect water, UV-LEDs at peak emission wavelengths of 265, 280, and 300 nm were adopted to inactivate pathogenic species, including Pseudomonas aeruginosa and Legionella pneumophila, and surrogate species, including Escherichia coli, Bacillus subtilis spores, and bacteriophage Qβ in water, compared to conventional low-pressure UV lamp emitting at 254 nm. The inactivation profiles of each species showed either a linear or sigmoidal survival curve, which both fit well with the Geeraerd's model. Based on the inactivation rate constant, the 265-nm UV-LED showed most effective fluence, except for with E. coli which showed similar inactivation rates at 265 and 254 nm. Electrical energy consumption required for 3-log 10 inactivation (E E,3 ) was lowest for the 280-nm UV-LED for all microbial species tested. Taken together, the findings of this study determined the inactivation profiles and kinetics of both pathogenic bacteria and surrogate species under UV-LED exposure at different wavelengths. We also demonstrated that not only inactivation rate constants, but also energy efficiency should be considered when selecting an emission wavelength for UV-LEDs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Occurrence of Legionella in UK household showers.

    Science.gov (United States)

    Collins, Samuel; Stevenson, David; Bennett, Allan; Walker, Jimmy

    2017-04-01

    Household water systems have been proposed as a source of sporadic, community acquired Legionnaires' disease. Showers represent a frequently used aerosol generating device in the domestic setting yet little is known about the occurrence of Legionella spp. in these systems. This study has investigated the prevalence of Legionella spp. by culture and qPCR in UK household showers. Ninety nine showers from 82 separate properties in the South of England were sampled. Clinically relevant Legionella spp. were isolated by culture in 8% of shower water samples representing 6% of households. Legionella pneumophila sg1 ST59 was isolated from two showers in one property and air sampling demonstrated its presence in the aerosol state. A further 31% of showers were positive by Legionella spp. qPCR. By multi-variable binomial regression modelling Legionella spp. qPCR positivity was associated with the age of the property (p=0.02), the age of the shower (p=0.01) and the frequency of use (p=0.09). The concentration of Legionella spp. detected by qPCR was shown to decrease with increased frequency of use (p=0.04) and more frequent showerhead cleaning (p=0.05). There was no association between Legionella spp. qPCR positivity and the cold water supply or the showerhead material (p=0.65 and p=0.71, respectively). Household showers may be important reservoirs of clinically significant Legionella and should be considered in source investigations. Simple public health advice may help to mitigate the risk of Legionella exposure in the domestic shower environment. Crown Copyright © 2016. Published by Elsevier GmbH. All rights reserved.

  7. Fatal pneumonia by Legionella in a farmer with hypersensitivity pneumonitis Neumonía por Legionella con desenlace fatal en un granjero con neumonitis por hipersensibilidad

    Directory of Open Access Journals (Sweden)

    Vega García López

    2009-12-01

    Full Text Available Background: The retrospective investigation of a fatal sporadic Legionnaires' disease identified an unknown case of occupational hypersensitivity pneumonitis in a swine breeder. Methods: Chest high-resolution computed tomography, bronchoalveolar lavage, lung biopsy, arterial gasometry, pulmonary function tests and autopsy were performed. It was studied the presence of Legionella by serology and risk water samples were analyzed to identify the Legionella's source. Results: HP and Legionella pneumophila pneumonia diagnostics were confirmed. Lung fibrosis, a restrictive functional pattern, decreased diffusion, hypoxemia and bronchoalveolar lavage lymphocytosis were evidenced. Legionella´s source was detected in a shower and a positive serology in the patient. Autopsy verified pulmonary fibrosis and the septic shock leaded to Legionella causing the death. Conclusions: Chronic cough and pulmonary infiltrates in a farmer should suspect the presence of hypersensitivity pneumonitis. Later diagnosis carries a worse prognosis, the offending antigens exposure can't be avoided and fibrotic stage enhanced opportunity infection disease.Introducción: La investigación retrospectiva sobre un fallecimiento aislado por Legionelosis, hizo aflorar un caso de neumonitis por hipersensibilidad en un granjero cuidador de cerdos. Métodos: Se realizaron las siguientes pruebas: tomografía axial computerizada de alta resolución, lavado broncoalveolar, biopsia pulmonar, gasometría arterial, pruebas de función respiratoria y autopsia. Se estudió la presencia de Legionella por serología y se analizaron las muestras de fuentes de riesgo para identificar el foco de Legionella. Resultados: El estudio confirmó los diagnósticos de neumonitis por hipersensibilidad y neumonía por Legionella pneumophila. Las pruebas realizadas objetivaron la fibrosis pulmonar, un patrón respiratorio funcional restrictivo, un descenso de la difusión pulmonar, hipoxemia y la presencia de

  8. Distribution of monoclonal antibody subgroups and sequence-based types among Legionella pneumophila serogroup 1 isolates derived from cooling tower water, bathwater, and soil in Japan.

    Science.gov (United States)

    Amemura-Maekawa, Junko; Kikukawa, Kiyomi; Helbig, Jürgen H; Kaneko, Satoko; Suzuki-Hashimoto, Atsuko; Furuhata, Katsunori; Chang, Bin; Murai, Miyo; Ichinose, Masayuki; Ohnishi, Makoto; Kura, Fumiaki

    2012-06-01

    Legionella pneumophila serogroup (SG) 1 is the most frequent cause of legionellosis. This study analyzed environmental isolates of L. pneumophila SG 1 in Japan using monoclonal antibody (MAb) typing and sequence-based typing (SBT). Samples were analyzed from bathwater (BW; n = 50), cooling tower water (CT; n = 50), and soil (SO; n = 35). The distribution of MAb types varied by source, with the most prevalent types being Bellingham (42%), Oxford (72%), and OLDA (51%) in BW, CT, and SO, respectively. The ratios of MAb 3/1 positive isolates were 26, 2, and 14% from BW, CT, and SO, respectively. The environmental isolates from BW, CT, and SO were divided into 34 sequence types (STs; index of discrimination [IOD] = 0.973), 8 STs (IOD = 0.448), and 11 STs (IOD = 0.879), respectively. Genetic variation among CT isolates was smaller than seen in BW and SO. ST1 accounted for 74% of the CT isolates. The only common STs between (i) BW and CT, (ii) BW and SO, and (iii) CT and SO were ST1, ST129, and ST48, respectively, suggesting that each environment constitutes an independent habitat.

  9. The Legionella pneumophila IcmSW complex interacts with multiple Dot/Icm effectors to facilitate type IV translocation.

    Directory of Open Access Journals (Sweden)

    Eric D Cambronne

    2007-12-01

    Full Text Available Many gram-negative pathogens use a type IV secretion system (T4SS to deliver effector proteins into eukaryotic host cells. The fidelity of protein translocation depends on the efficient recognition of effector proteins by the T4SS. Legionella pneumophila delivers a large number of effector proteins into eukaryotic cells using the Dot/Icm T4SS. How the Dot/Icm system is able to recognize and control the delivery of effectors is poorly understood. Recent studies suggest that the IcmS and IcmW proteins interact to form a stable complex that facilitates translocation of effector proteins by the Dot/Icm system by an unknown mechanism. Here we demonstrate that the IcmSW complex is necessary for the productive translocation of multiple Dot/Icm effector proteins. Effector proteins that were able to bind IcmSW in vitro required icmS and icmW for efficient translocation into eukaryotic cells during L. pneumophila infection. We identified regions in the effector protein SidG involved in icmSW-dependent translocation. Although the full-length SidG protein was translocated by an icmSW-dependent mechanism, deletion of amino terminal regions in the SidG protein resulted in icmSW-independent translocation, indicating that the IcmSW complex is not contributing directly to recognition of effector proteins by the Dot/Icm system. Biochemical and genetic studies showed that the IcmSW complex interacts with a central region of the SidG protein. The IcmSW interaction resulted in a conformational change in the SidG protein as determined by differences in protease sensitivity in vitro. These data suggest that IcmSW binding to effectors could enhance effector protein delivery by mediating a conformational change that facilitates T4SS recognition of a translocation domain located in the carboxyl region of the effector protein.

  10. Effect of Various Water Chemistry Factors on Legionella Proliferation and the Premise Plumbing Microbiome Composition

    OpenAIRE

    Proctor, Caitlin Rose

    2014-01-01

    Premise plumbing, the pipes and fixtures at the building level, present a unique challenge for maintaining drinking water quality. Of particular concern are opportunistic pathogens, including Legionella pneumophila which can regrow in premise plumbing and cause disease in immunocompromised populations. The goal of this work was to explore engineering methods for control of L. pneumophila and total regrowth. The first line of study involved a series of experiments with simulated glass water he...

  11. Molecular Typing of Legionella pneumophila Isolates in the Province of Quebec from 2005 to 2015.

    Directory of Open Access Journals (Sweden)

    Simon Lévesque

    Full Text Available Legionella is found in natural and man-made aquatic environments, such as cooling towers and hot water plumbing infrastructures. Legionella pneumophila serogroup 1 (Lp1 is the most common etiological agent causing waterborne disease in the United States and Canada. This study reports the molecular characterization of Lp strains during a 10 year period. We conducted sequence-based typing (SBT analysis on a large set of Lp isolates (n = 284 to investigate the province of Quebec sequence types (STs distribution in order to identify dominant clusters. From 2005 to 2015, 181 clinical Lp isolates were typed by SBT (141 sporadic cases and 40 outbreak related cases. From the same period of time, 103 environmental isolates were also typed. Amongst the 108 sporadic cases of Lp1 typed, ST-62 was the most frequent (16.6%, followed by ST-213 (10.2%, ST-1 (8.3% and ST-37 (8.3%. Amongst other serogroups (SG, ST-1327 (SG5 (27.3% and ST-378 (SG10 (12.2% were the most frequent. From the environmental isolates, ST-1 represent the more frequent SBT type (26.5%. Unweighted pair group method with arithmetic mean (UPGMA dendrogram from the 108 sporadic cases of SG1 contains 4 major clusters (A to D of related STs. Cluster B contains the majority of the strains (n = 61 and the three most frequent STs in our database (ST-62, ST-213 and ST-1. During the study period, we observed an important increase in the incidence rate in Quebec. All the community associated outbreaks, potentially or confirmed to be associated with a cooling tower were caused by Lp1 strains, by opposition to hospital associated outbreaks that were caused by serogroups of Lp other than SG1. The recent major Quebec City outbreak caused by ST-62, and the fact that this genotype is the most common in the province supports whole genome sequencing characterization of this particular sequence type in order to understand its evolution and associated virulence factors.

  12. High Prevalence, Genetic Diversity and Intracellular Growth Ability of Legionella in Hot Spring Environments

    Science.gov (United States)

    Zhou, Haijian; Wang, Huanxin; Xu, Ying; Zhao, Mingqiang; Guan, Hong; Li, Machao; Shao, Zhujun

    2013-01-01

    Background Legionella is the causative agent of Legionnaires' disease, and hot springs are a major source of outbreaks of this disease. It is important from a public health perspective to survey hot spring environments for the presence of Legionella. Methods Prospective surveillance of the extent of Legionella pollution was conducted at three hot spring recreational areas in Beijing, China in 2011. Pulsed-field gel electrophoresis (PFGE) and sequence-based typing (SBT) were used to describe the genetic polymorphism of isolates. The intracellular growth ability of the isolates was determined by interacting with J774 cells and plating the dilutions onto BCYE agar plates. Results Overall, 51.9% of spring water samples showed Legionella-positive, and their concentrations ranged from 1 CFU/liter to 2,218 CFU/liter. The positive rates of Legionella were significantly associated with a free chlorine concentration of ≥0.2 mg/L, urea concentration of ≥0.05 mg/L, total microbial counts of ≥400 CFU/ml and total coliform of ≥3 MPN/L (pLegionella concentrations were significantly associated with sample temperature, pH, total microbial counts and total coliform (pLegionella pneumophila was the most frequently isolated species (98.9%), and the isolated serogroups included serogroups 3 (25.3%), 6 (23.4%), 5 (19.2%), 1 (18.5%), 2 (10.2%), 8 (0.4%), 10 (0.8%), 9 (1.9%) and 12 (0.4%). Two hundred and twenty-eight isolates were analyzed by PFGE and 62 different patterns were obtained. Fifty-seven L. pneumophila isolates were selected for SBT analysis and divided into 35 different sequence types with 5 main clonal groups. All the 57 isolates had high intracellular growth ability. Conclusions Our results demonstrated high prevalence and genetic polymorphism of Legionella in springs in Beijing, China, and the SBT and intracellular growth assay results suggested that the Legionella isolates of hot spring environments were pathogenic. Improved control and prevention strategies are

  13. High prevalence, genetic diversity and intracellular growth ability of Legionella in hot spring environments.

    Directory of Open Access Journals (Sweden)

    Tian Qin

    Full Text Available BACKGROUND: Legionella is the causative agent of Legionnaires' disease, and hot springs are a major source of outbreaks of this disease. It is important from a public health perspective to survey hot spring environments for the presence of Legionella. METHODS: Prospective surveillance of the extent of Legionella pollution was conducted at three hot spring recreational areas in Beijing, China in 2011. Pulsed-field gel electrophoresis (PFGE and sequence-based typing (SBT were used to describe the genetic polymorphism of isolates. The intracellular growth ability of the isolates was determined by interacting with J774 cells and plating the dilutions onto BCYE agar plates. RESULTS: Overall, 51.9% of spring water samples showed Legionella-positive, and their concentrations ranged from 1 CFU/liter to 2,218 CFU/liter. The positive rates of Legionella were significantly associated with a free chlorine concentration of ≥0.2 mg/L, urea concentration of ≥0.05 mg/L, total microbial counts of ≥400 CFU/ml and total coliform of ≥3 MPN/L (p<0.01. The Legionella concentrations were significantly associated with sample temperature, pH, total microbial counts and total coliform (p<0.01. Legionella pneumophila was the most frequently isolated species (98.9%, and the isolated serogroups included serogroups 3 (25.3%, 6 (23.4%, 5 (19.2%, 1 (18.5%, 2 (10.2%, 8 (0.4%, 10 (0.8%, 9 (1.9% and 12 (0.4%. Two hundred and twenty-eight isolates were analyzed by PFGE and 62 different patterns were obtained. Fifty-seven L. pneumophila isolates were selected for SBT analysis and divided into 35 different sequence types with 5 main clonal groups. All the 57 isolates had high intracellular growth ability. CONCLUSIONS: Our results demonstrated high prevalence and genetic polymorphism of Legionella in springs in Beijing, China, and the SBT and intracellular growth assay results suggested that the Legionella isolates of hot spring environments were pathogenic. Improved control

  14. Occurrence and parameters of frequency of Legionella in warm water systems of hospitals and hotels in Lower Saxony.

    Science.gov (United States)

    Habicht, W; Müller, H E

    1988-03-01

    A total of 1241 water samples was investigated from 103 hospitals and 62 hotels in Lower Saxony 1985-87. 331 of 949 samples from hospitals and 26 of 292 samples from hotels were Legionella positive. All together 70% of the hospitals and 18% of the hotels investigated were Legionella positive, and 836 strains of Legionella were isolated (Table 1). As they could be diagnosed they belong to L. pneumophila SG1 306 strains, SG2 36 strains, SG3 127 strains, SG4 45 strain, SG5 29 strain, SG6 106 strains, SG9 13 strains and SG10 13 strains. Further 134 strains belonging to L. pneumophila but not to SG1-SG12 show cross reactions with serogroups 5, 8, and 10. Finally, 16 strains belong to L. dumoffii and 1 strain to L. anisa (Table 2). The following parameters of water samples were studied, too: temperature, pH value, conductivity, concentration of iron, of organic matter, of other bacteria, occurrence of amoebas, and the materials of water plumbing systems. Most samples contained concentrations of Legionella in the range of 10(1)-10(3) CFU/ml, highest concentrations were 10(5) CFU/ml (Fig. 1). Most frequently, Legionella were isolated within the range of temperature of 35-45 degrees C. However, a few of the water samples were positive for Legionella even up to 66 degrees C (Fig. 3). The conductivity has no and the pH value (Fig. 2) has only little influence on the occurrence of Legionella. There is a positive correlation between concentration of iron and frequency of Legionella (Fig. 4). Also organic matter (Fig. 6) and amoebas (Table 3) seem to enhance the occurrence of Legionella. Plumbing systems consisting of copper showed an inhibitory effect on Legionella during the first five years, whereas no effect could be detected in older systems (Fig. 5).

  15. Riesgos por Legionella, Prevención y Control

    OpenAIRE

    Martín Romero, Magdalena

    2014-01-01

    Para un buen control de riesgos por Legionella pneumophila, es importante conocer con detalle esta bacteria, los efectos que causa en el hombre, las principales fuentes de contagio y los medios para evitarlo. Este es el objetivo del presente trabajo. La legionelosis a pesar de ser percibida como una enfermedad infecciosa potencialmente erradicable, se puede controlar con medidas higiénico- sanitarias en las instalaciones implicadas.

  16. [Outbreak of hospital acquired Legionnaires' disease in patients of ophthalmic ward. Nosocomial Legionella infections for the first time observed in Poland].

    Science.gov (United States)

    Stypułkowska-Misiurewicz, Hanna; Pancer, Katarzyna; Krogulska, Bozena; Matuszewska, Renata

    2007-01-01

    The aim of the paper is to describe the criteria used for identification of first and so far the only one outbreak of hospital bacterial infections due to L. pneumophila. The infected persons were patients hospitalized at ophthalmic ward for more than 10 days. Four patients were found ill among 27 hospitalized (15%) at ophthalmic ward and 3 of them died (75%) in spite treatment in intensive care unit. The source of infection was found in the hospital hot water system. It was shown that L. pneumophila sg 1 and sg 2-14 were settled in the tanks and pipelines of hot water installations. The high number of L. pneumophila sg I and sg 2-14 colony forming units (> 10 000 cfu /100 ml) were found in the water specimens taken from the hospital water system, showing the high risk of Legionella infection for patients. Cleaning and disinfection of hot water system was repeated three times using composition every time modified as stronger mechanical, thermal and chemical methods. Complete elimination of Legionella from hot water system was achieved after cutting off deadlegs of water and replacement of both old hot water reservoirs with new ones. Collected experience served for preparation of guidelines for control and prevention of Legionella infections in hospital buildings, published on National Institute of Hygiene web site A month later Polish Ministry of Health published the Directives concerning the quality of drinking water to which the control of Legionella infection has been included.

  17. The Life Cycle of L. pneumophila: Cellular Differentiation Is Linked to Virulence and Metabolism

    Directory of Open Access Journals (Sweden)

    Giulia Oliva

    2018-01-01

    Full Text Available Legionella pneumophila is a gram-negative bacterium that inhabits freshwater ecosystems, where it is present in biofilm or as planktonic form. L. pneumophila is mainly found associated with protozoa, which serve as protection from hostile environments and as replication niche. If inhaled within aerosols, L. pneumophila is also able to infect and replicate in human alveolar macrophages, eventually causing the Legionnaires' disease. The transition between intracellular and extracellular environments triggers a differentiation program in which metabolic as well as morphogenetic changes occur. We here describe the current knowledge on how the different developmental states of this bacterium are regulated, with a particular emphasis on the stringent response activated during the transition from the replicative phase to the infectious phase and the metabolic features going in hand. We propose that the cellular differentiation of this intracellular pathogen is closely associated to key metabolic changes in the bacterium and the host cell, which together have a crucial role in the regulation of L. pneumophila virulence.

  18. Interactive Effects of Corrosion, Copper, and Chloramines on Legionella and Mycobacteria in Hot Water Plumbing.

    Science.gov (United States)

    Rhoads, William J; Pruden, Amy; Edwards, Marc A

    2017-06-20

    Complexities associated with drinking water plumbing systems can result in undesirable interactions among plumbing components that undermine engineering controls for opportunistic pathogens (OPs). In this study, we examine the effects of plumbing system materials and two commonly applied disinfectants, copper and chloramines, on water chemistry and the growth of Legionella and mycobacteria across a transect of bench- and pilot-scale hot water experiments carried out with the same municipal water supply. We discovered that copper released from corrosion of plumbing materials can initiate evolution of >1100 times more hydrogen (H 2 ) from water heater sacrificial anode rods than does presence of copper dosed as soluble cupric ions. H 2 is a favorable electron donor for autotrophs and causes fixation of organic carbon that could serve as a nutrient for OPs. Dosed cupric ions acted as a disinfectant in stratified stagnant pipes, inhibiting culturable Legionella and biofilm formation, but promoted Legionella growth in pipes subject to convective mixing. This difference was presumably due to continuous delivery of nutrients to biofilm on the pipes under convective mixing conditions. Chloramines eliminated culturable Legionella and prevented L. pneumophila from recolonizing biofilms, but M. avium gene numbers increased by 0.14-0.76 logs in the bulk water and were unaffected in the biofilm. This study provides practical confirmation of past discrepancies in the literature regarding the variable effects of copper on Legionella growth, and confirms prior reports of trade-offs between Legionella and mycobacteria if chloramines are applied as secondary disinfectant residual.

  19. Uncovering the Legionella genus effector repertoire - strength in diversity and numbers

    Science.gov (United States)

    Burstein, David; Amaro, Francisco; Zusman, Tal; Lifshitz, Ziv; Cohen, Ofir; Gilbert, Jack A; Pupko, Tal; Shuman, Howard A; Segal, Gil

    2016-01-01

    Infection by the human pathogen Legionella pneumophila relies on the translocation of ~300 virulence proteins, termed effectors, which manipulate host-cell processes. However, almost no information exists regarding effectors in other Legionella pathogens. Here we sequenced, assembled and characterized the genomes of 38 Legionella species, and predicted their effector repertoire using a previously validated machine-learning approach. This analysis revealed a treasure trove of 5,885 predicted effectors. The effector repertoire of different Legionella species was found to be largely non-overlapping, and only seven core-effectors were shared among all species studied. Species-specific effectors had atypically low GC content, suggesting exogenous acquisition, possibly from their natural protozoan hosts. Furthermore, we detected numerous novel conserved effector domains, and discovered new domain combinations, which allowed inferring yet undescribed effector functions. The effector collection and network of domain architectures described here can serve as a roadmap for future studies of effector function and evolution. PMID:26752266

  20. Analysis of the Legionella longbeachae genome and transcriptome uncovers unique strategies to cause Legionnaires' disease.

    Directory of Open Access Journals (Sweden)

    Christel Cazalet

    2010-02-01

    Full Text Available Legionella pneumophila and L. longbeachae are two species of a large genus of bacteria that are ubiquitous in nature. L. pneumophila is mainly found in natural and artificial water circuits while L. longbeachae is mainly present in soil. Under the appropriate conditions both species are human pathogens, capable of causing a severe form of pneumonia termed Legionnaires' disease. Here we report the sequencing and analysis of four L. longbeachae genomes, one complete genome sequence of L. longbeachae strain NSW150 serogroup (Sg 1, and three draft genome sequences another belonging to Sg1 and two to Sg2. The genome organization and gene content of the four L. longbeachae genomes are highly conserved, indicating strong pressure for niche adaptation. Analysis and comparison of L. longbeachae strain NSW150 with L. pneumophila revealed common but also unexpected features specific to this pathogen. The interaction with host cells shows distinct features from L. pneumophila, as L. longbeachae possesses a unique repertoire of putative Dot/Icm type IV secretion system substrates, eukaryotic-like and eukaryotic domain proteins, and encodes additional secretion systems. However, analysis of the ability of a dotA mutant of L. longbeachae NSW150 to replicate in the Acanthamoeba castellanii and in a mouse lung infection model showed that the Dot/Icm type IV secretion system is also essential for the virulence of L. longbeachae. In contrast to L. pneumophila, L. longbeachae does not encode flagella, thereby providing a possible explanation for differences in mouse susceptibility to infection between the two pathogens. Furthermore, transcriptome analysis revealed that L. longbeachae has a less pronounced biphasic life cycle as compared to L. pneumophila, and genome analysis and electron microscopy suggested that L. longbeachae is encapsulated. These species-specific differences may account for the different environmental niches and disease epidemiology of these

  1. Antibody-modified iron oxide nanoparticles for efficient magnetic isolation and flow cytometric determination of L. pneumophila

    International Nuclear Information System (INIS)

    Bloemen, Maarten; Verbiest, Thierry; Denis, Carla; Meester, Luc De; Peeters, Miet; Gils, Ann; Geukens, Nick

    2015-01-01

    We report on the design of superparamagnetic nanoparticles capable of selectively isolating targeted bacteria (Legionella pneumophila, serogroup 1) from aqueous solutions. The surface of magnetite nanoparticles (NP) was functionalized with a heterobifunctional poly(ethylene glycol) ligand containing reactive groups for covalent coupling of polyclonal antibodies against L. pneumophila. These bioconjugates were used to label and magnetically isolate L. pneumophila. Flow cytometry revealed high separation and efficiency in this regard. The strain specificity and efficiency of the magnetic NP was tested with recombinant strains of E. coli (expressing the red fluorescent protein) and L. pneumophila (expressing the green fluorescent protein). The detection limit of the method (by flow cytometry) is 10 4 cells∙mL -1 . The results indicate that the new multifunctional NPs are capable of selectively attracting pathogens from a complex mixture and with high efficiency. This, conceivably, paves the way to pre-concentration protocols for numerous other pathogens. (author)

  2. Legionella pneumonia associated with severe acute respiratory distress syndrome and diffuse alveolar hemorrhage - A rare association

    Directory of Open Access Journals (Sweden)

    Muhammad Kashif

    2017-01-01

    Full Text Available Legionella pneumophila is a common, usually underreported and undiagnosed cause of community acquired pneumonia which can lead to significant morbidity and mortality. Diffuse alveolar hemorrhage rarely have been associated with legionella infection. We present a 61-year-old man with hypertension, diabetes mellitus and obesity admitted with severe acute respiratory distress syndrome. He was found to have Legionella pneumonia with associated diffuse alveolar hemorrhage diagnosed with bronchoscopic sequential bronchoalveolar lavage. He was successfully managed with antibiotics, lung protective strategies and intravenous pulse dose steroids. This patient highlights the unusual association of Legionella infection and diffuse alveolar hemorrhage. Additionally, the case re-enforces the need for early and aggressive evaluation and management of patients presenting with pneumonia and progressive hypoxia despite adequate treatment.

  3. Approach to determine the diversity of Legionella species by nested PCR-DGGE in aquatic environments

    Science.gov (United States)

    Huang, Wen-Chien; Tsai, Hsin-Chi; Tao, Chi-Wei; Chen, Jung-Sheng; Shih, Yi-Jia; Kao, Po-Min; Huang, Tung-Yi; Hsu, Bing-Mu

    2017-01-01

    In this study, we describe a nested PCR-DGGE strategy to detect Legionella communities from river water samples. The nearly full-length 16S rRNA gene was amplified using bacterial primer in the first step. After, the amplicons were employed as DNA templates in the second PCR using Legionella specific primer. The third round of gene amplification was conducted to gain PCR fragments apposite for DGGE analysis. Then the total numbers of amplified genes were observed in DGGE bands of products gained with primers specific for the diversity of Legionella species. The DGGE patterns are thus potential for a high-throughput preliminary determination of aquatic environmental Legionella species before sequencing. Comparative DNA sequence analysis of excised DGGE unique band patterns showed the identity of the Legionella community members, including a reference profile with two pathogenic species of Legionella strains. In addition, only members of Legionella pneumophila and uncultured Legionella sp. were detected. Development of three step nested PCR-DGGE tactic is seen as a useful method for studying the diversity of Legionella community. The method is rapid and provided sequence information for phylogenetic analysis. PMID:28166249

  4. [Presence of Legionella spp. in household drinking water reservoirs in Resistencia, Chaco, Argentina. Preliminary report].

    Science.gov (United States)

    Lösch, Liliana S; Merino, Luis A

    Legionella spp. is an environmental bacterium that can survive in a wide range of physicochemical conditions and may colonize distribution systems of drinking water and storage tanks. Legionella pneumophila is the major waterborne pathogen that can cause 90% of Legionnaires' disease cases. The aim of this study was to detect the presence of Legionella spp. in household drinking water tanks in the city of Resistencia, Chaco. The detection of Legionella in water samples was performed by culture methods as set out in ISO 11731:1998. Thirty two water samples were analyzed and Legionella spp. was recovered in 12 (37.5%) of them. The monitoring of this microorganism in drinking water is the first step towards addressing the control of its spread to susceptible hosts. Copyright © 2016 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  5. Minimum inhibitory concentration distribution in environmental Legionella spp. isolates.

    Science.gov (United States)

    Sandalakis, Vassilios; Chochlakis, Dimosthenis; Goniotakis, Ioannis; Tselentis, Yannis; Psaroulaki, Anna

    2014-12-01

    In Greece standard tests are performed in the watering and cooling systems of hotels' units either as part of the surveillance scheme or following human infection. The purpose of this study was to establish the minimum inhibitory concentration (MIC) distributions of environmental Legionella isolates for six antimicrobials commonly used for the treatment of Legionella infections, by MIC-test methodology. Water samples were collected from 2004 to 2011 from 124 hotels from the four prefectures of Crete (Greece). Sixty-eight (68) Legionella isolates, comprising L. pneumophila serogroups 1, 2, 3, 5, 6, 8, 12, 13, 15, L. anisa, L. rubrilucens, L. maceachernii, L. quinlivanii, L. oakridgensis, and L. taurinensis, were included in the study. MIC-tests were performed on buffered charcoal yeast extract with α-ketoglutarate, L-cysteine, and ferric pyrophosphate. The MICs were read after 2 days of incubation at 36 ± 1 °C at 2.5% CO2. A large distribution in MICs was recorded for each species and each antibiotic tested. Rifampicin proved to be the most potent antibiotic regardless of the Legionella spp.; tetracycline appeared to have the least activity on our environmental isolates. The MIC-test approach is an easy, although not so cost-effective, way to determine MICs in Legionella spp. These data should be kept in mind especially since these Legionella species may cause human disease.

  6. Seasonal variation of Legionella in Taiwan's reservoir and its relationships with environmental factors.

    Science.gov (United States)

    Kao, Po-Min; Hsu, Bing-Mu; Chang, Tien-Yu; Hsu, Tsui-Kang; Tzeng, Kai-Jiun; Huang, Yu-Li

    2015-04-01

    In this study, the presence of Legionella in major water reservoirs of Taiwan was examined with respect to seasonal variation, geographical variation, and water quality parameters using TaqMan real-time qPCR. Water samples were collected quarterly at 19 reservoirs in Taiwan between November 2012 and August 2013. The detection rate for Legionella was 35.5% (27/76), and Legionella was detected in all seasons. The Legionella concentration was relatively high in spring and summer, reaching 3.86 × 10(8) and 7.35 × 10(8) cells/L, respectively. By sampling the area, Legionella was detected at a higher proportion in reservoirs in the northern and southern areas, and the difference was consistent in all seasons. Significant association was found between detection of Legionella and various water quality parameters, including conductivity, chlorophyll a, and dissolved oxygen (Mann-Whitney U test, P Legionella detection with pH (P = 0.030, R = -0.497) and dissolved oxygen (P = 0.007, R = -0.596) in fall and positive correlation with Carlson's trophic state index (P = 0.049, R = 0.457) in spring. The identified species included Legionella pneumophila and Legionella drancourtii. The detection of Legionella in reservoirs was indicative of a potential public health risk and should be further evaluated.

  7. Legionella pollution in cooling tower water of air-conditioning systems in Shanghai, China.

    Science.gov (United States)

    Lin, H; Xu, B; Chen, Y; Wang, W

    2009-02-01

    To determine Legionella pollution prevalence, describe the amount of Legionellae with respect to temperature in Shanghai cooling tower water (CTWs) in various types of public sites. Six urban districts were selected as the study fields, adopting multiple-phase sampling methods. Routine culture was used to identify Legionellae. Of the samples, 58.9% (189/321) were observed to be positive, 19.9% were isolated over 100 CFU ml(-1). Legionella pneumophila serogroup 1 was the most frequently isolated species (155/189, 82.0%), followed by Leg. micdadei that was at the second place (44/189, 23.3%). The mean CFU ml(-1) of Legionellae in CTWs reached its peak from July to September. Over all 15.4% of the samples exceeding 100 CFU ml(-1) were observed in a hospital setting. The prevalence of Legionella pollution in CTWs, especially in CTWs of subway stations and hospitals, is worrying, and the positive rate and CFU ml(-1) of Legionellae in CTWs have a close relationship with air temperature. The study demonstrates pollution prevalence rates in different types of sites and various seasons, and provides a proportion of different serogroups of Legionellae. It illuminates an urgent need for dealing with the potential risk of legionellosis in Shanghai, through improved control and prevention strategies.

  8. Molecular Survey of the Occurrence of Legionella spp., Mycobacterium spp., Pseudomonas aeruginosa, and Amoeba Hosts in Two Chloraminated Drinking Water Distribution Systems

    Science.gov (United States)

    Wang, Hong; Edwards, Marc; Falkinham, Joseph O.

    2012-01-01

    The spread of opportunistic pathogens via public water systems is of growing concern. The purpose of this study was to identify patterns of occurrence among three opportunistic pathogens (Legionella pneumophila, Mycobacterium avium, and Pseudomonas aeruginosa) relative to biotic and abiotic factors in two representative chloraminated drinking water distribution systems using culture-independent methods. Generally, a high occurrence of Legionella (≥69.0%) and mycobacteria (100%), lower occurrence of L. pneumophila (≤20%) and M. avium (≤33.3%), and rare detection of Pseudomonas aeruginosa (≤13.3%) were observed in both systems according to quantitative PCR. Also, Hartmanella vermiformis was more prevalent than Acanthamoeba, both of which are known hosts for opportunistic pathogen amplification, the latter itself containing pathogenic members. Three-minute flushing served to distinguish distribution system water from plumbing in buildings (i.e., premise plumbing water) and resulted in reduced numbers of copies of Legionella, mycobacteria, H. vermiformis, and 16S rRNA genes (P Legionella and H. vermiformis, were noted, emphasizing potential microbial ecological relationships. Overall, the results provide insight into factors that may aid in controlling opportunistic pathogen proliferation in real-world water systems. PMID:22752174

  9. Combined use of real-time PCR and nested sequence-based typing in survey of human Legionella infection.

    Science.gov (United States)

    Qin, T; Zhou, H; Ren, H; Shi, W; Jin, H; Jiang, X; Xu, Y; Zhou, M; Li, J; Wang, J; Shao, Z; Xu, X

    2016-07-01

    Legionnaires' disease (LD) is a globally distributed systemic infectious disease. The burden of LD in many regions is still unclear, especially in Asian countries including China. A survey of Legionella infection using real-time PCR and nested sequence-based typing (SBT) was performed in two hospitals in Shanghai, China. A total of 265 bronchoalveolar lavage fluid (BALF) specimens were collected from hospital A between January 2012 and December 2013, and 359 sputum specimens were collected from hospital B throughout 2012. A total of 71 specimens were positive for Legionella according to real-time PCR focusing on the 5S rRNA gene. Seventy of these specimens were identified as Legionella pneumophila as a result of real-time PCR amplification of the dotA gene. Results of nested SBT revealed high genetic polymorphism in these L. pneumophila and ST1 was the predominant sequence type. These data revealed that the burden of LD in China is much greater than that recognized previously, and real-time PCR may be a suitable monitoring technology for LD in large sample surveys in regions lacking the economic and technical resources to perform other methods, such as urinary antigen tests and culture methods.

  10. Acanthamoeba and Dictyostelium as Cellular Models for Legionella Infection

    Science.gov (United States)

    Swart, A. Leoni; Harrison, Christopher F.; Eichinger, Ludwig; Steinert, Michael; Hilbi, Hubert

    2018-01-01

    Environmental bacteria of the genus Legionella naturally parasitize free-living amoebae. Upon inhalation of bacteria-laden aerosols, the opportunistic pathogens grow intracellularly in alveolar macrophages and can cause a life-threatening pneumonia termed Legionnaires' disease. Intracellular replication in amoebae and macrophages takes place in a unique membrane-bound compartment, the Legionella-containing vacuole (LCV). LCV formation requires the bacterial Icm/Dot type IV secretion system, which translocates literally hundreds of “effector” proteins into host cells, where they modulate crucial cellular processes for the pathogen's benefit. The mechanism of LCV formation appears to be evolutionarily conserved, and therefore, amoebae are not only ecologically significant niches for Legionella spp., but also useful cellular models for eukaryotic phagocytes. In particular, Acanthamoeba castellanii and Dictyostelium discoideum emerged over the last years as versatile and powerful models. Using genetic, biochemical and cell biological approaches, molecular interactions between amoebae and Legionella pneumophila have recently been investigated in detail with a focus on the role of phosphoinositide lipids, small and large GTPases, autophagy components and the retromer complex, as well as on bacterial effectors targeting these host factors. PMID:29552544

  11. Acanthamoeba and Dictyostelium as Cellular Models for Legionella Infection

    Directory of Open Access Journals (Sweden)

    A. Leoni Swart

    2018-03-01

    Full Text Available Environmental bacteria of the genus Legionella naturally parasitize free-living amoebae. Upon inhalation of bacteria-laden aerosols, the opportunistic pathogens grow intracellularly in alveolar macrophages and can cause a life-threatening pneumonia termed Legionnaires' disease. Intracellular replication in amoebae and macrophages takes place in a unique membrane-bound compartment, the Legionella-containing vacuole (LCV. LCV formation requires the bacterial Icm/Dot type IV secretion system, which translocates literally hundreds of “effector” proteins into host cells, where they modulate crucial cellular processes for the pathogen's benefit. The mechanism of LCV formation appears to be evolutionarily conserved, and therefore, amoebae are not only ecologically significant niches for Legionella spp., but also useful cellular models for eukaryotic phagocytes. In particular, Acanthamoeba castellanii and Dictyostelium discoideum emerged over the last years as versatile and powerful models. Using genetic, biochemical and cell biological approaches, molecular interactions between amoebae and Legionella pneumophila have recently been investigated in detail with a focus on the role of phosphoinositide lipids, small and large GTPases, autophagy components and the retromer complex, as well as on bacterial effectors targeting these host factors.

  12. Effects of Disinfection on Legionella spp., Eukarya, and Biofilms in a Hot Water System

    Science.gov (United States)

    Moletta-Denat, Marina; Frère, Jacques; Onillon, Séverine; Trouilhé, Marie-Cécile; Robine, Enric

    2012-01-01

    Legionella species are frequently detected in hot water systems, attached to the surface as a biofilm. In this work, the dynamics of Legionella spp. and diverse bacteria and eukarya associated together in the biofilm, coming from a pilot scale 1 system simulating a real hot water system, were investigated throughout 6 months after two successive heat shock treatments followed by three successive chemical treatments. Community structure was assessed by a fingerprint technique, single-strand conformation polymorphism (SSCP). In addition, the diversity and dynamics of Legionella and eukarya were investigated by small-subunit (SSU) ribosomal cloning and sequencing. Our results showed that pathogenic Legionella species remained after the heat shock and chemical treatments (Legionella pneumophila and Legionella anisa, respectively). The biofilm was not removed, and the bacterial community structure was transitorily affected by the treatments. Moreover, several amoebae had been detected in the biofilm before treatments (Thecamoebae sp., Vannella sp., and Hartmanella vermiformis) and after the first heat shock treatment, but only H. vermiformis remained. However, another protozoan affiliated with Alveolata, which is known as a host cell for Legionella, dominated the eukaryal species after the second heat shock and chemical treatment tests. Therefore, effective Legionella disinfection may be dependent on the elimination of these important microbial components. We suggest that eradicating Legionella in hot water networks requires better study of bacterial and eukaryal species associated with Legionella in biofilms. PMID:22820326

  13. Legionella spp. in UK composts--a potential public health issue?

    Science.gov (United States)

    Currie, S L; Beattie, T K; Knapp, C W; Lindsay, D S J

    2014-04-01

    Over the past 5 years, a number of cases of legionellosis in Scotland have been associated with compost use; however, studies investigating sources of infection other than water systems remain limited. This study delivers the first comprehensive survey of composts commonly available in the UK for the presence of Legionella species. Twenty-two store-bought composts, one green-waste compost and one home-made compost were tested for Legionella by culture methods on BCYE-α medium, and the findings were confirmed by macrophage infectivity potentiator (mip) speciation. Twenty-two of the samples were retested after an enrichment period of 8 weeks. In total, 15 of 24 composts tested positive for Legionella species, a higher level of contamination than previously seen in Europe. Two isolates of Legionella pneumophila were identified, and Legionella longbeachae serogroup 1 was found to be one of the most commonly isolated species. L. longbeachae infection would not be detected by routine Legionella urinary antigen assay, so such testing should not be used as the sole diagnostic technique in atypical pneumonia cases, particularly where there is an association with compost use. The occurrence of Legionella in over half of the samples tested indicates that compost could pose a public health risk. The addition of general hygiene warnings to compost packages may be beneficial in protecting public health. © 2013 The Authors Clinical Microbiology and Infection © 2013 European Society of Clinical Microbiology and Infectious Diseases.

  14. Genome Dynamics in Legionella: The Basis of Versatility and Adaptation to Intracellular Replication

    Science.gov (United States)

    Gomez-Valero, Laura; Buchrieser, Carmen

    2013-01-01

    Legionella pneumophila is a bacterial pathogen present in aquatic environments that can cause a severe pneumonia called Legionnaires’ disease. Soon after its recognition, it was shown that Legionella replicates inside amoeba, suggesting that bacteria replicating in environmental protozoa are able to exploit conserved signaling pathways in human phagocytic cells. Comparative, evolutionary, and functional genomics suggests that the Legionella–amoeba interaction has shaped this pathogen more than previously thought. A complex evolutionary scenario involving mobile genetic elements, type IV secretion systems, and horizontal gene transfer among Legionella, amoeba, and other organisms seems to take place. This long-lasting coevolution led to the development of very sophisticated virulence strategies and a high level of temporal and spatial fine-tuning of bacteria host–cell interactions. We will discuss current knowledge of the evolution of virulence of Legionella from a genomics perspective and propose our vision of the emergence of this human pathogen from the environment. PMID:23732852

  15. Detection of Legionella spp. from Domestic Water in the Prefecture of Arta, Greece

    Directory of Open Access Journals (Sweden)

    Dimitra Dimitriadi

    2014-01-01

    Full Text Available The aim of this research was the isolation of Legionella spp. from domestic water supply networks in the Prefecture of Arta. A total of 100 water samples, from 25 houses, were collected. Half of the samples concerned the cold water and half the hot water supply. Purpose was to detect colonization of the water networks with Legionella spp. >500 cfu/L by using the method of filtration (ISO 11731. Out of 100 samples, 6 samples from 3 houses were positive for Legionella spp. Legionella pneumophila serogroup 2–14 was isolated in 5 of 6 samples, whereas in the sixth sample Legionella anisa was identified. Only three of the samples had residual chloride over 0.2 mg/L, rate which is necessary for potable water, according to the Greek hygienic practice. Concerning the temperature of hot water, the mean temperature of the negative for Legionella samples was higher compared to the mean temperature of the positive for Legionella samples (49.9°C versus 45.5°C. It is estimated that there is risk of infection through the use of showers. The low concentration of chloride and the temperature, which was found within the limits favorable to developing Legionella spp. (20–45°C, provide fertile ground for proliferation of the bacteria.

  16. Mistaken identity: Legionella micdadei appearing as acid-fast bacilli on lung biopsy of a hematopoietic stem cell transplant patient.

    Science.gov (United States)

    Waldron, P R; Martin, B A; Ho, D Y

    2015-02-01

    Legionella micdadei is a potential cause of invasive lung infections in immunocompromised hosts. On biopsy specimens, it can appear as an acid-fast bacillus (AFB) and can be mistaken for a member of genus Mycobacterium. As Legionella requires selective media to grow in culture, and the commonly used, commercially available urine antigen test for Legionella only detects Legionella pneumophila serogroup-1, but not L. micdadei, it is important to consider this organism in the differential diagnosis for AFB in immunocompromised hosts. We report a case of L. micdadei infection, which was initially treated empirically for non-tuberculous mycobacteria based on AFB staining of biopsy tissue before the final diagnosis was made. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Prevalence of Legionella spp. in water systems of hospitals and hotels in South Western Greece.

    Science.gov (United States)

    Fragou, K; Kokkinos, P; Gogos, C; Alamanos, Y; Vantarakis, A

    2012-01-01

    The aim of the present study was to determine the prevalence of Legionella spp. in water systems of hospitals and hotels located in South Western Greece, to study the molecular epidemiology of the isolated strains and their possible association with bacterial contamination (total count and Pseudomonas aeruginosa), the water pH, and temperature. A prevalence survey for Legionella spp. by culturing techniques in water distribution systems of eight hospitals and nine hotels occurred in South Western Greece. Water sampling and microbiological analysis were carried out following the ISO methods. Legionella pneumophila was detected in 33% and 36% of the distribution systems of hospitals and hotels, respectively. Our survey results suggest a frequent prevalence of elevated concentrations of Legionella spp. in water systems of hospitals and hotels. Our investigation has confirmed the need to regularly monitor the microbiological condition of water systems in hospitals and hotels.

  18. PCR method for the rapid detection and discrimination of Legionella spp. based on the amplification of pcs, pmtA, and 16S rRNA genes.

    Science.gov (United States)

    Janczarek, Monika; Palusińska-Szysz, Marta

    2016-05-01

    Legionella bacteria are organisms of public health interest due to their ability to cause pneumonia (Legionnaires' disease) in susceptible humans and their ubiquitous presence in water supply systems. Rapid diagnosis of Legionnaires' disease allows the use of therapy specific for the disease. L. pneumophila serogroup 1 is the most common cause of infection acquired in community and hospital environments. The non-L. pneumophila infections are likely under-detected because of a lack of effective diagnosis. In this work, simplex and duplex PCR assays with the use of new molecular markers pcs and pmtA involved in phosphatidylcholine synthesis were specified for rapid and cost-efficient identification and distinguishing Legionella species. The sets of primers developed were found to be sensitive and specific for reliable detection of Legionella belonging to the eight most clinically relevant species. Among these, four primer sets I, II, VI, and VII used for duplex-PCRs proved to have the highest identification power and reliability in the detection of the bacteria. Application of this PCR-based method should improve detection of Legionella spp. in both clinical and environmental settings and facilitate molecular typing of these organisms.

  19. Bacterial community dynamics in a cooling tower with emphasis on pathogenic bacteria and Legionella species using universal and genus-specific deep sequencing.

    Science.gov (United States)

    Pereira, Rui P A; Peplies, Jörg; Höfle, Manfred G; Brettar, Ingrid

    2017-10-01

    Cooling towers are the major source of outbreaks of legionellosis in Europe and worldwide. These outbreaks are mostly associated with Legionella species, primarily L. pneumophila, and its surveillance in cooling tower environments is of high relevance to public health. In this study, a combined NGS-based approach was used to study the whole bacterial community, specific waterborne and water-based bacterial pathogens, especially Legionella species, targeting the 16S rRNA gene. This approach was applied to water from a cooling tower obtained by monthly sampling during two years. The studied cooling tower was an open circuit cooling tower with lamellar cooling situated in Braunschweig, Germany. A highly diverse bacterial community was observed with 808 genera including 25 potentially pathogenic taxa using universal 16S rRNA primers. Sphingomonas and Legionella were the most abundant pathogenic genera. By applying genus-specific primers for Legionella, a diverse community with 85 phylotypes, and a representative core community with substantial temporal heterogeneity was observed. A high percentage of sequences (65%) could not be affiliated to an acknowledged species. L. pneumophila was part of the core community and the most abundant Legionella species reinforcing the importance of cooling towers as its environmental reservoir. Major temperature shifts (>10 °C) were the key environmental factor triggering the reduction or dominance of the Legionella species in the Legionella community dynamics. In addition, interventions by chlorine dioxide had a strong impact on the Legionella community composition but not on the whole bacterial community. Overall, the presented results demonstrated the value of a combined NGS approach for the molecular monitoring and surveillance of health related pathogens in man-made freshwater systems. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Colonization of Legionella species in Turkish baths in hotels in Alanya, Turkey.

    Science.gov (United States)

    Erdogan, Haluk; Arslan, Hande

    2015-05-01

    This study evaluated the prevalence of Legionella species in water samples collected from Turkish baths in hotels in Alanya, Turkey, from August 2003 to September 2013. Water samples were collected in 100-mL sterile containers and then concentrated by filtration. Heat treatment was used to eliminate other microorganisms from the samples, which were then spread on Legionella-selective-buffered charcoal yeast extract alpha (BCYE-α) agar and on BCYE-α agar supplemented with glycine, vancomycin, polymyxin, and cycloheximide. Cysteine-dependent colonies were identified by latex agglutination. In total, 135 samples from 52 hotels with Turkish baths were evaluated. Legionella species were identified in 11/52 (21.2%) hotels and 18/135 (13.3%) samples. The most frequently isolated species was Legionella pneumophila, with most isolates belonging to serogroups 6 (55.6%) and 1 (22.2%). The colony count was 1000 CFU mL(-1) in three samples. These findings suggest that the hot water systems of Turkish baths in hotels must be viewed as a possible source of travel-associated Legionnaires' disease, and preventative measures should be put in place.

  1. Legionella contamination in hot water systems of hospitals, nursing homes, hotels, factories and spas in Tuscany-Italy

    Directory of Open Access Journals (Sweden)

    Antonella Lo Nostro

    2011-03-01

    Full Text Available

    Abstract Following the report of many cases of Legionnaires’ disease associated with accommodation facilities such as hotels, spas, workplaces, hospitals and nursing homes, we verified if Legionella pneumophila and Legionella spp. were present in some of those structures in Tuscany, in order to estimate the species and serogroups in circulation. Legionella pneumophila serogroup 1 (30.9% was the most frequently isolated species along with serogroups 3 (16.1% and 6 (13.3%; these three serogroups are identified, in literature, as those most responsible for Legionnaires’ disease (LD. Studying all analyzed structures, we found some parts of the water system where Legionella concentration was higher than 103CFU/L, indicated, in Italy, as the maximum admitted concentration value above which a decontamination treatment is necessary when one or more cases of healthcare-acquired Legionnaires’ disease are observed. Moreover disinfection is recommended in any case when counts exceed 104CFU/L.
    Consequently, in order to prevent cases of Legionnaires’ disease, a continuous surveillance of the water
    systems of all accommodation facilities is necessary, with particular attention to hospitals and nursing
    homes where immunocompromised patients lodge, so as to promptly estimate the presence of the pathogen and consequently plan the most suitable intervention activities. We concluded that, in any structure, a continuous surveillance and disinfecting treatment of water systems is necessary. Moreover, after any disinfection treatment the temperature of the hot water flowing in the system must be necessarily maintained near 51°C in order to minimize the probability of recontamination from Legionella and limit the
    risk of LD in consumers.

  2. Functional Analysis of the Alternative Sigma-28 Factor FliA and Its Anti-Sigma Factor FlgM of the Nonflagellated Legionella Species L. oakridgensis.

    Science.gov (United States)

    Tlapák, Hana; Rydzewski, Kerstin; Schulz, Tino; Weschka, Dennis; Schunder, Eva; Heuner, Klaus

    2017-06-01

    Legionella oakridgensis causes Legionnaires' disease but is known to be less virulent than Legionella pneumophila L. oakridgensis is one of the Legionella species that is nonflagellated. The genes of the flagellar regulon are absent, except those encoding the alternative sigma-28 factor (FliA) and its anti-sigma-28 factor (FlgM). Similar to L. oakridgensis , Legionella adelaidensis and Legionella londiniensis , located in the same phylogenetic clade, have no flagellar regulon, although both are positive for fliA and flgM Here, we investigated the role and function of both genes to better understand the role of FliA, the positive regulator of flagellin expression, in nonflagellated strains. We demonstrated that the FliA gene of L. oakridgensis encodes a functional sigma-28 factor that enables the transcription start from the sigma-28-dependent promoter site. The investigations have shown that FliA is necessary for full fitness of L. oakridgensis Interestingly, expression of FliA-dependent genes depends on the growth phase and temperature, as already shown for L. pneumophila strains that are flagellated. In addition, we demonstrated that FlgM is a negative regulator of FliA-dependent gene expression. FlgM seems to be degraded in a growth-phase- and temperature-dependent manner, instead of being exported into the medium as reported for most bacteria. The degradation of FlgM leads to an increase of FliA activity. IMPORTANCE A less virulent Legionella species, L. oakridgensis , causes Legionnaires' disease and is known to not have flagella, even though L. oakridgensis has the regulator of flagellin expression (FliA). This protein has been shown to be involved in the expression of virulence factors. Thus, the strain was chosen for use in this investigation to search for FliA target genes and to identify putative virulence factors of L. oakridgensis One of the five major target genes of FliA identified here encodes the anti-FliA sigma factor FlgM. Interestingly, in

  3. Relationships between Free-Living Protozoa, Cultivable Legionella spp., and Water Quality Characteristics in Three Drinking Water Supplies in the Caribbean▿†

    OpenAIRE

    Valster, Rinske M.; Wullings, Bart A.; van den Berg, Riemsdijk; van der Kooij, Dick

    2011-01-01

    The study whose results are presented here aimed at identifying free-living protozoa (FLP) and conditions favoring the growth of these organisms and cultivable Legionella spp. in drinking water supplies in a tropical region. Treated and distributed water (±30°C) of the water supplies of three Caribbean islands were sampled and investigated with molecular techniques, based on the 18S rRNA gene. The protozoan host Hartmannella vermiformis and cultivable Legionella pneumophila were observed in a...

  4. High prevalence of Legionella in non-passenger merchant vessels.

    Science.gov (United States)

    Collins, S L; Stevenson, D; Mentasti, M; Shaw, A; Johnson, A; Crossley, L; Willis, C

    2017-03-01

    There is a paucity of information on the risk from potable water in non-passenger merchant vessels (NPMVs) particularly with regard to Legionella and other bacteria. This retrospective study examined water samples from 550 NPMVs docked in eight UK ports. A total of 1027 samples from 412 NPMVs were examined for total aerobic colony counts (ACC), coliforms, Escherichia coli and enterococci; 41% of samples yielded ACC above the action level (>1 × 103 c.f.u./ml) and 4·5% contained actionable levels (>1 c.f.u./100 ml) of faecal indicator bacteria. Eight hundred and three samples from 360 NPMVs were cultured specifically for Legionella and 58% of vessels proved positive for these organisms with 27% of samples showing levels greater than the UK upper action limit of 1 × 103 c.f.u./l. Cabin showers (49%) and hospital shower (45%) were frequently positive. A subset of 106 samples was analysed by quantitative polymerase chain reaction for Legionella and identified a further 11 Legionella-positive NPMVs, returning a negative predictive value of 100%. There was no correlation between NPMV age or size and any microbial parameters (P > 0·05). Legionella pneumophila serogroup 1 was isolated from 46% of NPMVs and sequence-based typing of 17 isolates revealed four sequence types (STs) previously associated with human disease. These data raise significant concerns regarding the management of microbial and Legionella risks on board NPMVs and suggest that better guidance and compliance are required to improve control.

  5. Rash, disseminated intravascular coagulation and legionella: Episode 10 and a rewind into the past

    Directory of Open Access Journals (Sweden)

    Prashanth M. Thalanayar

    2015-01-01

    Full Text Available Legionella pneumophila is the most common cause of legionellosis and is one of the organisms causing atypical pneumonia. We report the presentation of disseminated intravascular coagulation (DIC and skin rash in a single case of severe Legionella pneumonia. The unique clinical presentation of a diffuse rash diagnosed as purpura fulminans and the unpredictable variations encountered during the diagnostic work-up of the case make this write-up crucial. This article synthesizes all reported cases of L. pneumonia associated with cutaneous manifestations as well as cases presenting with DIC. Furthermore, this manuscript illustrates the correlation between cutaneous and coagulopathic manifestations, and morbidity and mortality from L. pneumonia.

  6. DIAGNOSTICO SEROLÓGICO DE NEUMONIA POR LEGIONELLA. INCIDENCIA EN UN PERIODO DE TRES AÑOS EN EL AREA SANITARIA OESTE DE VALLADOLID

    Directory of Open Access Journals (Sweden)

    M.A. Mazón

    2005-12-01

    Full Text Available ABSTRACT:Introduction: Legionella species are Gram-negative bacilli. There are described for the first time in 70's associated to the Legionnarie's disease. Presently, more than 34 species of Legionella have been identified, 20 of which have been found pathogenic for the man. The clinical manifestations of Legionella infections are primarily respiratory. The most common presentation is acute pneumonia, which varies in severity from mild illness that does not require hospitalization to fatal pneumonia.Material and Methods: The results corresponding to the determination of antibodies to L. pneumophila (Gull Laboratories by indirect inmunofluorescence (IFI have been analysed and reviewed. This conventional inmunofluorescent test measures antibodies versus a pool of 1, 2, 3, 4, 5, 6, 7 and 8 serogroups. During the 3 years of surveillance period 1249 determinations by IFI were performed in our Hospital. The determination of urinary antigen of Legionella for the qualitative detection of the antigen to L. pneumophila serogroup 1 was made in almost all studied samples by using a fast inmunochromatographical technique (Binax NOW.Results and Discussion: Of the 1249 cases of nosocomial pneumonia (diagnosed by a positive result of IFI Legionella test recorded during the period, 12 cases met the criteria for infection with L. pneumophila serogroup 1. Later, clinical histories were reviewed and it was observed that the ages of the confirmed cases oscillated between the 40 and 87 years, with an average of age of 40, of which 8 were men and 4 women. From the point of view of factors of risk, 6 patients were smokers. Clinically, the displayed symptoms were general malaise, fever high and pattern of pulmonary infiltration in all the cases, migraine in 3 cases, diarrhoea in 5 cases and arthralgias and muscle aches in 3 cases. The analytical parameters in common were high VSG and leukocytosis. Hyponatremia 1/1024, what it demonstrates a clear seroconversion. In

  7. Prevalence of Legionella in premise plumbing in Hungary.

    Science.gov (United States)

    Barna, Zsófia; Kádár, Mihály; Kálmán, Emese; Scheirich Szax, Anita; Vargha, Márta

    2016-03-01

    Legionella is one of the emerging concerns of water quality in built water environments. Premise plumbing systems are among the recognised sources of infection. In the present study, colonisation of hot water networks in health care facilities, schools, hotels, private residences, office and industrial buildings was investigated. Data was analysed in connection with building and premise plumbing characteristics. Over 60% of all buildings were colonised by Legionella; counts were over 1000 CFU/L in 49%. The most prevalent type was Legionella pneumophila serogroup 2-14, isolated from 75% of the positive samples. Centrally produced hot water was found to be a key risk factor (46% of the samples were positive vs. 16% in individual systems); within this group the type of the building was less relevant. Colonisation levels in schools were similar to hotels or hospitals, representing a previously underestimated risk setting. Systems supplied by water from deep groundwater sources were significantly less likely to be colonised than more vulnerable sources (bank-wall filtration, surface water abstraction or karstic water; 28% vs. 51% positive), regardless of the type of treatment applied, including the presence of disinfection. The aggravating effect of larger, more complex and older buildings on colonisation was also confirmed. The present study represents the first baseline analysis, pre-empting regulation or monitoring requirements for Legionella. The prevalence of legionellae and the identified risk factors are indicative for other settings lacking targeted interventions. The statistically confirmed risk factors can serve as indicators for preliminary risk assessment and the prioritisation of interventions. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Microbiological diagnosis and molecular typing of Legionella strains during an outbreak of legionellosis in Southern Germany.

    Science.gov (United States)

    Essig, Andreas; von Baum, Heike; Gonser, Theodor; Haerter, Georg; Lück, Christian

    2016-02-01

    An explosive outbreak of Legionnaires' disease with 64 reported cases occurred in Ulm/Neu-Ulm in the South of Germany in December 2009/January 2010 caused by Legionella (L.) pneumophila serogroup 1, monoclonal (mAb) subtype Knoxville, sequence type (ST) 62. Here we present the clinical microbiological results from 51 patients who were diagnosed at the University hospital of Ulm, the results of the environmental investigations and of molecular typing of patients and environmental strains. All 50 patients from whom urine specimens were available were positive for L. pneumophila antigen when an enzyme-linked immunosorbent assay (EIA) was used following concentration of those urine samples that tested initially negative. The sensitivity of the BinaxNow rapid immunographic assay (ICA), after 15 min reading and after 60 min reading were 70% and 84%, respectively. Direct typing confirmed the monoclonal subtype Knoxville in 5 out of 8 concentrated urine samples. Real time PCR testing of respiratory tract specimens for L. pneumophila was positive in 15 out of 25 (60%) patients. Direct nested sequence based typing (nSBT) in some of these samples allowed partial confirmation of ST62. L. pneumophila serogroup 1, monoclonal subtype Knoxville ST62, defined as the epidemic strain was isolated from 8 out of 31 outbreak patients (26%) and from one cooling tower confirming it as the most likely source of the outbreak. While rapid detection of Legionella antigenuria was crucial for the recognition and management of the outbreak, culture and molecular typing of the strains from patients and environmental specimens was the clue for the rapid identification of the source of infection. Copyright © 2016 Elsevier GmbH. All rights reserved.

  9. Prevalence and Molecular Characteristics of Waterborne Pathogen Legionella in Industrial Cooling Tower Environments.

    Science.gov (United States)

    Li, Lijie; Qin, Tian; Li, Yun; Zhou, Haijian; Song, Hongmei; Ren, Hongyu; Li, Liping; Li, Yongguang; Zhao, Dong

    2015-10-12

    Cooling towers are a source of Legionnaires' disease. It is important from a public health perspective to survey industrial cooling towers for the presence of Legionella. Prospective surveillance of the extent of Legionella pollution was conducted at factories in Shijiazhuang, China between March 2011 and September 2012. Overall, 35.7% of 255 industrial cooling tower water samples showed Legionella-positive, and their concentrations ranged from 100 Colony-Forming Units (CFU)/liter to 88,000 CFU/liter, with an average concentration of 9100 CFU/liter. A total of 121 isolates were obtained. All isolates were L. pneumophila, and the isolated serogroups included serogroups 1 (68 isolates, 56.2%), 6 (25, 20.7%), 5 (12, 9.9%), 8 (8, 6.6%), 3 (6, 5.0%) and 9 (2, 1.6%). All 121 isolates were analyzed by pulsed-field gel electrophoresis (PFGE) and 64 different patterns were obtained. All 121 isolates were analyzed sequence-based typing (SBT), a full 7-allele profile was obtained from 117 isolates. One hundred and seventeen isolates were divided into 49 sequence types. Two virulence genes, lvh and rtxA, are analyzed by polymerase chain reaction (PCR). 92.6% (112/121) and 98.3% (119/121) isolates carried lvh and rtxA respectively and 90.9% (110/121) of tested isolates carried both genes. Our results demonstrated high prevalence and genetic polymorphism of L. pneumophila in industrial cooling tower environments in Shijiazhang, China, and the SBT and virulence gene PCR results suggested that the isolates were pathogenic. Improved control and prevention strategies are urgently needed.

  10. Prevalence and Molecular Characteristics of Waterborne Pathogen Legionella in Industrial Cooling Tower Environments

    Directory of Open Access Journals (Sweden)

    Lijie Li

    2015-10-01

    Full Text Available Cooling towers are a source of Legionnaires’ disease. It is important from a public health perspective to survey industrial cooling towers for the presence of Legionella. Prospective surveillance of the extent of Legionella pollution was conducted at factories in Shijiazhuang, China between March 2011 and September 2012. Overall, 35.7% of 255 industrial cooling tower water samples showed Legionella-positive, and their concentrations ranged from 100 Colony-Forming Units (CFU/liter to 88,000 CFU/liter, with an average concentration of 9100 CFU/liter. A total of 121 isolates were obtained. All isolates were L. pneumophila, and the isolated serogroups included serogroups 1 (68 isolates, 56.2%, 6 (25, 20.7%, 5 (12, 9.9%, 8 (8, 6.6%, 3 (6, 5.0% and 9 (2, 1.6%. All 121 isolates were analyzed by pulsed-field gel electrophoresis (PFGE and 64 different patterns were obtained. All 121 isolates were analyzed sequence-based typing (SBT, a full 7-allele profile was obtained from 117 isolates. One hundred and seventeen isolates were divided into 49 sequence types. Two virulence genes, lvh and rtxA, are analyzed by polymerase chain reaction (PCR. 92.6% (112/121 and 98.3% (119/121 isolates carried lvh and rtxA respectively and 90.9% (110/121 of tested isolates carried both genes. Our results demonstrated high prevalence and genetic polymorphism of L. pneumophila in industrial cooling tower environments in Shijiazhang, China, and the SBT and virulence gene PCR results suggested that the isolates were pathogenic. Improved control and prevention strategies are urgently needed.

  11. Comparative analyses of Legionella species identifies genetic features of strains causing Legionnaires' disease.

    Science.gov (United States)

    Gomez-Valero, Laura; Rusniok, Christophe; Rolando, Monica; Neou, Mario; Dervins-Ravault, Delphine; Demirtas, Jasmin; Rouy, Zoe; Moore, Robert J; Chen, Honglei; Petty, Nicola K; Jarraud, Sophie; Etienne, Jerome; Steinert, Michael; Heuner, Klaus; Gribaldo, Simonetta; Médigue, Claudine; Glöckner, Gernot; Hartland, Elizabeth L; Buchrieser, Carmen

    2014-01-01

    The genus Legionella comprises over 60 species. However, L. pneumophila and L. longbeachae alone cause over 95% of Legionnaires’ disease. To identify the genetic bases underlying the different capacities to cause disease we sequenced and compared the genomes of L. micdadei, L. hackeliae and L. fallonii (LLAP10), which are all rarely isolated from humans. We show that these Legionella species possess different virulence capacities in amoeba and macrophages, correlating with their occurrence in humans. Our comparative analysis of 11 Legionella genomes belonging to five species reveals highly heterogeneous genome content with over 60% representing species-specific genes; these comprise a complete prophage in L. micdadei, the first ever identified in a Legionella genome. Mobile elements are abundant in Legionella genomes; many encode type IV secretion systems for conjugative transfer, pointing to their importance for adaptation of the genus. The Dot/Icm secretion system is conserved, although the core set of substrates is small, as only 24 out of over 300 described Dot/Icm effector genes are present in all Legionella species. We also identified new eukaryotic motifs including thaumatin, synaptobrevin or clathrin/coatomer adaptine like domains. Legionella genomes are highly dynamic due to a large mobilome mainly comprising type IV secretion systems, while a minority of core substrates is shared among the diverse species. Eukaryotic like proteins and motifs remain a hallmark of the genus Legionella. Key factors such as proteins involved in oxygen binding, iron storage, host membrane transport and certain Dot/Icm substrates are specific features of disease-related strains.

  12. Legionella spp. Risk Assessment in Recreational and Garden Areas of Hotels

    Directory of Open Access Journals (Sweden)

    Antonios Papadakis

    2018-03-01

    Full Text Available Several Travel-associated Legionnaires’ disease (TALD cases occur annually in Europe. Except from the most obvious sites (cooling towers and hot water systems, infections can also be associated with recreational, water feature, and garden areas of hotels. This argument is of great interest to better comprehend the colonization and to calculate the risk to human health of these sites. From July 2000–November 2017, the public health authorities of the Island of Crete (Greece inspected 119 hotels associated with TALD, as reported through the European Legionnaires’ Disease Surveillance Network. Five hundred and eighteen samples were collected from decorative fountain ponds, showers near pools and spas, swimming pools, spa pools, garden sprinklers, drip irrigation systems (reclaimed water and soil. Of those, 67 (12.93%, originating from 43 (35.83% hotels, tested positive for Legionella (Legionella pneumophila serogroups 1, 2, 3, 6, 7, 8, 13, 14, 15 and non-pneumophila species (L. anisa, L. erythra, L. taurinensis, L. birminghamensis, L. rubrilucens. A Relative Risk (R.R. > 1 (p < 0.0001 was calculated for chlorine concentrations of less than 0.2 mg/L (R.R.: 54.78, star classification (<4 (R.R.: 4.75 and absence of Water Safety Plan implementation (R.R.: 3.96. High risk (≥104 CFU/L was estimated for pool showers (16.42%, garden sprinklers (7.46% and pool water (5.97%.

  13. Legionella spp. Risk Assessment in Recreational and Garden Areas of Hotels.

    Science.gov (United States)

    Papadakis, Antonios; Chochlakis, Dimosthenis; Sandalakis, Vassilios; Keramarou, Maria; Tselentis, Yannis; Psaroulaki, Anna

    2018-03-26

    Several Travel-associated Legionnaires' disease (TALD) cases occur annually in Europe. Except from the most obvious sites (cooling towers and hot water systems), infections can also be associated with recreational, water feature, and garden areas of hotels. This argument is of great interest to better comprehend the colonization and to calculate the risk to human health of these sites. From July 2000-November 2017, the public health authorities of the Island of Crete (Greece) inspected 119 hotels associated with TALD, as reported through the European Legionnaires' Disease Surveillance Network. Five hundred and eighteen samples were collected from decorative fountain ponds, showers near pools and spas, swimming pools, spa pools, garden sprinklers, drip irrigation systems (reclaimed water) and soil. Of those, 67 (12.93%), originating from 43 (35.83%) hotels, tested positive for Legionella ( Legionella pneumophila serogroups 1, 2, 3, 6, 7, 8, 13, 14, 15 and non-pneumophila species ( L. anisa , L. erythra , L. taurinensis , L. birminghamensis , L. rubrilucens ). A Relative Risk (R.R.) > 1 ( p < 0.0001) was calculated for chlorine concentrations of less than 0.2 mg/L (R.R.: 54.78), star classification (<4) (R.R.: 4.75) and absence of Water Safety Plan implementation (R.R.: 3.96). High risk (≥10⁴ CFU/L) was estimated for pool showers (16.42%), garden sprinklers (7.46%) and pool water (5.97%).

  14. ASSESSMENT OF INSTALLATION WATER QUALITY IN AN EDUCATIONAL BUILDING ON THE BASIS OF LEGIONELLA Sp. CONCENTRATION

    Directory of Open Access Journals (Sweden)

    Amelia Beata Staszowska

    2017-06-01

    Full Text Available Legionella are known as one of the dangerous water-borne pathogens, causing severe respiratory tract infections. The aim of this study was to assess the installation water quality in an educational building located in Lublin on the basis of Legionella sp. concentration and physicochemical parameters of cold and hot installation water. Samples (n=60 of cold and hot water were collected for testing from the 10 tapping points during three surveys over a period of five months. The test samples were analyzed for the basic physicochemical parameters of the water quality such as pH, electrical conductivity, temperature, hardness, alkalinity, the total carbon content, the concentration of nitrates, chlorides and sulphates. Additionally, the concentration of calcium, magnesium, iron, manganese and zinc were examined. The presence of Legionella in water samples was measured according the standard methods. The quality of the analyzed water did not raise objections and met the criteria of the Ordinance of the Polish Ministry of Health (2015, pos.1989. The only parameter which did not comply with applicable regulations was the temperature of the supply water and return hot water - it was lower than required. Bacteria of the genus Legionella were detected only in the hot water samples from series 1 when the rate of colonization reached the level of 80%. Among the positive samples, 2 contained less than 1000 CFU/100 ml, 4 samples contained 1x103 to 1x104 CFU/100 ml, and 2 samples contained more than 1x104 CFU/100 ml. The maximum number of CFU in a sample was 1.8x104/100 ml. The most dangerous serogroup L. pneumophila sg 1 was not detected in any of the positive isolated samples. All Legionella - positive samples belonged to L. pneumophila sg 2-14. These findings necessitated a corrective action in the form of thermal disinfection system and its maintenance. Its effectiveness was confirmed by the results of the survey of 2 and 3.

  15. Industrial Cooling Tower Disinfection Treatment to Prevent Legionella spp.

    Directory of Open Access Journals (Sweden)

    Matteo Iervolino

    2017-09-01

    Full Text Available The contamination of industrial cooling towers has been identified as one cause of legionellosis, but the real risk has been underestimated. Two different disinfection treatments were tested on Legionella colonization in an industrial Cooling Tower System (CTS. Environmental monitoring of Legionella, P. aeruginosa, and a heterotrophic plate count (HPC at 36 °C was performed from June to October 2016. The disinfection procedures adopted were based on hydrogen peroxide (H2O2 and silver salts (Ag+, in addition to an anti-algal treatment, then using hyperclorination as a shock, and then continuous treatment by sodium hypochlorite (NaClO. L. pneumophila serogroup 8 was found at a concentration of 5.06 Log cfu/L after the CTS filling; a shock treatment performed by H2O2/Ag+ produced a rapid increase in contamination up to 6.14 Log cfu/L. The CTS activity was stopped and two subsequent shock treatments were performed using NaClO, followed by continuous hyperclorination. These procedures showed a significant decrease (p < 0.05 in Legionella concentration (1.77 Log cfu/L. The same trend was observed for P. aeruginosa (0.55 Log cfu/100 mL and HPC (1.95 Log cfu/mL at 36 °C. Environmental monitoring and the adoption of maintenance procedures, including anti-scale treatment, and physical, chemical, and microbiological control, ensure the good performance of a CTS, reducing the Legionella risk for public health.

  16. Industrial Cooling Tower Disinfection Treatment to Prevent Legionella spp.

    Science.gov (United States)

    Iervolino, Matteo; Mancini, Benedetta; Cristino, Sandra

    2017-09-26

    The contamination of industrial cooling towers has been identified as one cause of legionellosis, but the real risk has been underestimated. Two different disinfection treatments were tested on Legionella colonization in an industrial Cooling Tower System (CTS). Environmental monitoring of Legionella , P. aeruginosa , and a heterotrophic plate count (HPC) at 36 °C was performed from June to October 2016. The disinfection procedures adopted were based on hydrogen peroxide (H₂O₂) and silver salts (Ag⁺), in addition to an anti-algal treatment, then using hyperclorination as a shock, and then continuous treatment by sodium hypochlorite (NaClO). L . pneumophila serogroup 8 was found at a concentration of 5.06 Log cfu/L after the CTS filling; a shock treatment performed by H₂O₂/Ag⁺ produced a rapid increase in contamination up to 6.14 Log cfu/L. The CTS activity was stopped and two subsequent shock treatments were performed using NaClO, followed by continuous hyperclorination. These procedures showed a significant decrease ( p Legionella concentration (1.77 Log cfu/L). The same trend was observed for P . aeruginosa (0.55 Log cfu/100 mL) and HPC (1.95 Log cfu/mL) at 36 °C. Environmental monitoring and the adoption of maintenance procedures, including anti-scale treatment, and physical, chemical, and microbiological control, ensure the good performance of a CTS, reducing the Legionella risk for public health.

  17. Anti-Legionella dumoffii Activity of Galleria mellonella Defensin and Apolipophorin III

    Directory of Open Access Journals (Sweden)

    Małgorzata Cytryńska

    2012-12-01

    Full Text Available The gram-negative bacterium Legionella dumoffii is, beside Legionella pneumophila, an etiological agent of Legionnaires’ disease, an atypical form of pneumonia. The aim of this study was to determine the antimicrobial activity of Galleria mellonella defense polypeptides against L. dumoffii. The extract of immune hemolymph, containing a mixture of defense peptides and proteins, exhibited a dose-dependent bactericidal effect on L. dumoffii. The bacterium appeared sensitive to a main component of the hemolymph extract, apolipophorin III, as well as to a defense peptide, Galleria defensin, used at the concentrations 0.4 mg/mL and 40 μg/mL, respectively. L. dumoffii cells cultured in the presence of choline were more susceptible to both defense factors analyzed. A transmission electron microscopy study of bacterial cells demonstrated that Galleria defensin and apolipophorin III induced irreversible cell wall damage and strong intracellular alterations, i.e., increased vacuolization, cytoplasm condensation and the appearance of electron-white spaces in electron micrographs. Our findings suggest that insects, such as G. mellonella, with their great diversity of antimicrobial factors, can serve as a rich source of compounds for the testing of Legionella susceptibility to defense-related peptides and proteins.

  18. Legionella cardiaca sp. nov., isolated from a case of native valve endocarditis in a human heart

    Science.gov (United States)

    Pearce, Meghan M.; Theodoropoulos, Nicole; Mandel, Mark J.; Brown, Ellen; Reed, Kurt D.

    2012-01-01

    A Gram-negative, rod-shaped bacterium, designated H63T, was isolated from aortic valve tissue of a patient with native valve endocarditis. 16S rRNA gene sequencing revealed that H63T belongs to the genus Legionella, with its closest neighbours being the type strains of Legionella brunensis (98.8 % similarity), L. londiniensis (97.0 %), L. jordanis (96.8 %), L. erythra (96.2 %), L. dresdenensis (96.0 %) and L. rubrilucens, L. feeleii, L. pneumophila and L. birminghamensis (95.7 %). DNA–DNA hybridization studies yielded values of Legionella. H63T was distinguishable from its neighbours based on it being positive for hippurate hydrolysis. H63T was further differentiated by its inability to grow on BCYE agar at 17 °C, its poor growth on low-iron medium and the absence of sliding motility. Also, H63T did not react with antisera generated from type strains of Legionella species. H63T replicated within macrophages. It also grew in mouse lungs, inducing histopathological evidence of pneumonia and dissemination to the spleen. Together, these results confirm that H63T represents a novel, pathogenic Legionella species, for which the name Legionella cardiaca sp. nov. is proposed. The type strain is H63T ( = ATCC BAA-2315T  = DSM 25049T  = JCM 17854T). PMID:22286905

  19. A hospital outbreak of Legionella from a contaminated water supply.

    Science.gov (United States)

    Tercelj-Zorman, Marjeta; Seljak, Marija; Stare, Janez; Mencinger, Joze; Rakovec, Joze; Rylander, Ragnar; Strle, Franc

    2004-03-01

    The authors performed a cross-sectional epidemiological survey to investigate the source of a hospital Legionella outbreak originating in contaminated water. Water temperature and air humidity were measured around possible contamination sources. A dead-end pipe was found to contain Legionella pneumophila serogroup 1. All individuals who acquired legionellosis had spent at least 30 min within 2 m of the contamination source. Among staff, 41 of 71 were exposed, and 31 of these fell ill. All 7 patients exposed to the contaminated water acquired legionellosis. None of the 94 bed-ridden patients from the same units developed the disease. An aerosol with 60% relative air humidity was formed near the suspect water faucets, but the humidity fell rapidly farther from the water source, suggesting that desiccation decreased the risk of infection. The healthy personnel and patients closest to the source acquired legionellosis, suggesting that risk was related less to compromised patients than to exposure.

  20. Legionella species colonization in cooling towers: risk factors and assessment of control measures.

    Science.gov (United States)

    Mouchtouri, Varvara A; Goutziana, Georgia; Kremastinou, Jenny; Hadjichristodoulou, Christos

    2010-02-01

    Cooling towers can be colonized by Legionella spp, and inhalation of aerosols generated by their operation may cause Legionnaires' disease in susceptible hosts. Environmental investigations of Legionnaires' disease outbreaks linked with cooling towers have revealed poorly maintained systems, lack of control measures, and failure of system equipment. The purpose of this study was to identify Legionella-contaminated cooling towers, identify risk factors for contamination, and assess the effectiveness of control measures. A total of 96 cooling towers of public buildings were registered and inspected, and 130 samples were collected and microbiologically tested. Microbiological test results were associated with characteristics of cooling towers, water samples, inspection results, and maintenance practices. Of the total 96 cooling towers examined, 47 (48.9%) were colonized by Legionella spp, and 22 (22.9%) required remedial action. A total of 65 samples (50.0%) were positive (> or = 500 cfu L(-1)), and 30 (23%) were heavily contaminated (> or = 10(4) cfu L(-1)). Of the 69 isolates identified, 55 strains (79.7.%) were L pneumophila. Legionella colonization was positively associated with the absence of training on Legionella control (relative risk [RR] = 1.66; P = .02), absence of regular Legionella testing (RR = 2.07: P = .002), absence of sunlight protection (RR = 1.63: P = .02), with samples in which the free residual chlorine level in the water sample was cooling towers (median, 17 years; interquartile range [IQR] =5.0 to 26.0 years) compared with noncolonized cooling towers (median age, 6 years; IQR =1.0 to 13.5 years). After the 22 legionellae-positive cooling towers were disinfected with chlorine, 2 (9%) of them remained positive for Legionella spp with a concentration > or = 1000 cfu L(-1). Cooling towers can be heavily colonized by Legionella spp and thus present a potential risk for infection. This study demonstrates the importance of a risk assessment and

  1. [i]Legionella spp[/i]., amoebae and not-fermenting Gram negative bacteria in an Italian university hospital water system

    Directory of Open Access Journals (Sweden)

    Pasqualina Laganà

    2014-09-01

    Full Text Available [b]Introduction. [/b]In hospital and other health care facilities, contamination of water systems by potentially infectious microorganisms, such as bacteria, viruses and protozoa, is a source of nosocomial infections, which may originate fromcolonization of water pipes, cooling towers, spa pools, taps, showers and water supplies. [b]Objective. [/b]The study focuses on the occurrence of [i]Legionella spp.[/i], free-living amoebae and non-fermenting Gram-negative microorganisms in a University hospital water system located in the town of Messina (Sicily, Italy, which had never been examined previously. Materials and Methods. From January 2008 – March 2009, hot tap water samples were collected from 10 wards.[i] Legionella spp[/i]. recovered on selective culture medium were identified by microagglutination latex test; free-living amoebae were cultured using [i]Escherichia coli [/i]as a food source. Non-fermenting Gram negative microorganisms were identified by API 20 NE strips. [b]Results.[/b] [i]Legionella spp.[/i] were found in 33.33% of the samples. [i]L. pneumophila[/i] serogroup 1 was recovered from the Laboratory Diagnostic and Anaesthesia-Neurology Wards, with a peak of 3.5 × 10[sup]4[/sup] cfu/L in May 2008. [i]L. pneumophila[/i] serogroups 2–14 were found in the Othorhinolaryngology, Pathologic Anatomy, Paediatrics and Surgery Wards, and peaked (4 × 10[sup]4[/sup] cfu/L in April 2008. Pseudomonadaceae and Hyphomycetes were also detected. Legionella spp. were recovered from samples positive for non-pathogenic amoebae [i]Hartmannella spp[/i]. [b]Conclusion.[/b] This first study of a Messina hospital water system suggested potential health risks related to the detection of [i]Hartmannella spp[/i]., as reservoirs for[i] Legionella spp.[/i], and Pseudomonas aeruginosa, a Gram negative non-fermenting bacterium frequently causing nosocomial pneumonia. The urgent need for monitoring programmes and prevention measures to ensure hospital water

  2. Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study.

    Science.gov (United States)

    Montagna, Maria Teresa; De Giglio, Osvalda; Cristina, Maria Luisa; Napoli, Christian; Pacifico, Claudia; Agodi, Antonella; Baldovin, Tatjana; Casini, Beatrice; Coniglio, Maria Anna; D'Errico, Marcello Mario; Delia, Santi Antonino; Deriu, Maria Grazia; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Moro, Matteo; Mura, Ida; Pennino, Francesca; Privitera, Gaetano; Romano Spica, Vincenzo; Sembeni, Silvia; Spagnolo, Anna Maria; Tardivo, Stefano; Torre, Ida; Valeriani, Federica; Albertini, Roberto; Pasquarella, Cesira

    2017-06-22

    Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis ® μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis ® μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis ® μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis ® μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations.

  3. Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study

    Science.gov (United States)

    Montagna, Maria Teresa; De Giglio, Osvalda; Cristina, Maria Luisa; Napoli, Christian; Pacifico, Claudia; Agodi, Antonella; Baldovin, Tatjana; Casini, Beatrice; Coniglio, Maria Anna; D’Errico, Marcello Mario; Delia, Santi Antonino; Deriu, Maria Grazia; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Moro, Matteo; Mura, Ida; Pennino, Francesca; Privitera, Gaetano; Romano Spica, Vincenzo; Sembeni, Silvia; Spagnolo, Anna Maria; Tardivo, Stefano; Torre, Ida; Valeriani, Federica; Albertini, Roberto; Pasquarella, Cesira

    2017-01-01

    Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis®μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis®μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis®μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis®μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations. PMID:28640202

  4. Occurrence of Legionella in hot water systems of single-family residences in suburbs of two German cities with special reference to solar and district heating.

    Science.gov (United States)

    Mathys, Werner; Stanke, Juliane; Harmuth, Margarita; Junge-Mathys, Elisabeth

    2008-03-01

    A total of 452 samples from hot water systems of randomly selected single family residences in the suburbs of two German cities were analysed for the occurrence of Legionella. Technical data were documented using a standardized questionnaire to evaluate possible factors promoting the growth of the bacterium in these small plumbing systems. All houses were supplied with treated groundwater from public water works. Drinking water quality was within the limits specified in the German regulations for drinking water and the water was not chlorinated. The results showed that plumbing systems in private houses that provided hot water from instantaneous water heaters were free of Legionella compared with a prevalence of 12% in houses with storage tanks and recirculating hot water where maximum counts of Legionella reached 100,000 CFU/100ml. The presence of L. pneumophila accounted for 93.9% of all Legionella positive specimens of which 71.8% belonged to serogroup 1. The volume of the storage tank, interrupting circulation for several hours daily and intermittently raising hot water temperatures to >60 degrees C had no influence on Legionella counts. Plumbing systems with copper pipes were more frequently contaminated than those made of synthetic materials or galvanized steel. An inhibitory effect due to copper was not present. Newly constructed systems (water preparation had a marked influence. More than 50% of all houses using district heating systems were colonized by Legionella. Their significantly lower hot water temperature is thought to be the key factor leading to intensified growth of Legionella. Although hot water systems using solar energy to supplement conventional hot water supplies operate at temperatures 3 degrees C lower than conventional systems, this technique does not seem to promote proliferation of the bacterium. Our data show convincingly that the temperature of the hot water is probably the most important or perhaps the only determinant factor for

  5. Legionella Effector AnkX Disrupts Host Cell Endocytic Recycling in a Phosphocholination-Dependent Manner

    Directory of Open Access Journals (Sweden)

    Samual C. Allgood

    2017-09-01

    Full Text Available The facultative intracellular bacterium Legionella pneumophila proliferates within amoebae and human alveolar macrophages, and it is the causative agent of Legionnaires' disease, a life-threatening pneumonia. Within host cells, L. pneumophila establishes a replicative haven by delivering numerous effector proteins into the host cytosol, many of which target membrane trafficking by manipulating the function of Rab GTPases. The Legionella effector AnkX is a phosphocholine transferase that covalently modifies host Rab1 and Rab35. However, a detailed understanding of the biological consequence of Rab GTPase phosphocholination remains elusive. Here, we broaden the understanding of AnkX function by presenting three lines of evidence that it interferes with host endocytic recycling. First, using immunogold transmission electron microscopy, we determined that GFP-tagged AnkX ectopically produced in mammalian cells localizes at the plasma membrane and tubular membrane compartments, sites consistent with targeting the endocytic recycling pathway. Furthermore, the C-terminal region of AnkX was responsible for association with the plasma membrane, and we determined that this region was also able to bind the phosphoinositide lipids PI(3P and PI(4P in vitro. Second, we observed that mCherry-AnkX co-localized with Rab35, a regulator of recycling endocytosis and with major histocompatibility class I protein (MHC-I, a key immunoregulatory protein whose recycling from and back to the plasma membrane is Rab35-dependent. Third, we report that during infection of macrophages, AnkX is responsible for the disruption of endocytic recycling of transferrin, and AnkX's phosphocholination activity is critical for this function. These results support the hypothesis that AnkX targets endocytic recycling during host cell infection. Finally, we have demonstrated that the phosphocholination activity of AnkX is also critical for inhibiting fusion of the Legionella

  6. Peracetic acid in the disinfection of a hospital water system contaminated with Legionella species.

    Science.gov (United States)

    Ditommaso, Savina; Biasin, Cinzia; Giacomuzzi, Monica; Zotti, Carla Maria; Cavanna, Alberto; Ruggenini Moiraghi, Angela

    2005-05-01

    To assess the efficacy of an alternative disinfection method for hospital water distribution systems contaminated with Legionella. Disinfection with peracetic acid was performed in a small hospital contaminated with L. pneumophila serotype 1. The disinfectant was used at concentrations of 50 ppm (first three surveillance phases) and 1,000 ppm (fourth surveillance phase) for 30 minutes. Environmental monitoring revealed that disinfection was maintained 1 week after treatment; however, levels of recontamination surpassing baseline values were detected after approximately 1 month. Comparison of water temperatures measured at the distal outlets showed a statistically significant association between temperature and bacterial load. The circulating water temperature was found to be lower in the two wards farthest away from the hot water production plant than in other wards. It was thought that the lower water temperature in the two wards promoted the bacterial growth even after disinfection. Peracetic acid may be useful in emergency situations, but does not provide definitive protection even if used monthly.

  7. Comparison of the sensitivity of the Legionella urinary antigen EIA kits from Binax and Biotest with urine from patients with infections caused by less common serogroups and subgroups of Legionella.

    Science.gov (United States)

    Olsen, C W; Elverdal, P; Jørgensen, C S; Uldum, S A

    2009-07-01

    The detection of urinary antigen is the most widely used method to diagnose Legionnaires' disease (LD), so it is important that these assays have a high sensitivity for the disease. In this study, we compare two kits for their ability to detect urinary antigen in urine samples from patients infected with Legionella species and L. pneumophila sero- and subgroups not considered as the most common causes of LD. Urine samples (n = 33) from 30 culture-proven cases of L. pneumophila serogroup (sg) 1, subgroup non-Pontiac infection, and urine samples (n = 35) from 32 cases of non-L. pneumophila species or non-sg 1 infection were examined using the Binax EIA and Biotest EIA kits. For both groups, the overall diagnostic sensitivity of the Binax kit was significantly better than the sensitivity of the Biotest kits (P < 0.0001). For the non-Pontiac group, the sensitivity was 81.8 and 42.4%, respectively, and for the non-sg1 group, it was 51.4 and 28.6%, respectively. It was concluded that the Binax kit was more suitable for the general diagnosis of LD than the Biotest kit, but we still need urinary antigen detection methods with higher sensitivity for non-sg1 LD.

  8. Experimental human-like model to assess the part of viable Legionella reaching the thoracic region after nebulization.

    Directory of Open Access Journals (Sweden)

    Jérémie Pourchez

    Full Text Available The incidence of Legionnaires' disease (LD in European countries and the USA has been constantly increasing since 1998. Infection of humans occurs through aerosol inhalation. To bridge the existing gap between the concentration of Legionella in a water network and the deposition of bacteria within the thoracic region (assessment of the number of viable Legionella, we validated a model mimicking realistic exposure through the use of (i recent technology for aerosol generation and (ii a 3D replicate of the human upper respiratory tract. The model's sensitivity was determined by monitoring the deposition of (i aerosolized water and Tc99m radio-aerosol as controls, and (ii bioaerosols generated from both Escherichia coli and Legionella pneumophila sg 1 suspensions. The numbers of viable Legionella prior to and after nebulization were provided by culture, flow cytometry and qPCR. This study was designed to obtain more realistic data on aerosol inhalation (vs. animal experimentation and deposition at the thoracic region in the context of LD. Upon nebulization, 40% and 48% of the initial Legionella inoculum was made of cultivable and non-cultivable cells, respectively; 0.7% of both populations reached the filter holder mimicking the thoracic region in this setup. These results are in agreement with experimental data based on quantitative microbial risk assessment methods and bring new methods that may be useful for preventing LD.

  9. The Toolbox for Uncovering the Functions of Legionella Dot/Icm Type IVb Secretion System Effectors: Current State and Future Directions

    Directory of Open Access Journals (Sweden)

    Gunnar N. Schroeder

    2018-01-01

    Full Text Available The defective in organelle trafficking/intracellular multiplication (Dot/Icm Type IVb secretion system (T4SS is the essential virulence factor for the intracellular life style and pathogenicity of Legionella species. Screens demonstrated that an individual L. pneumophila strain can use the Dot/Icm T4SS to translocate an unprecedented number of more than 300 proteins into host cells, where these, so called Icm/Dot-translocated substrates (IDTS or effectors, manipulate host cell functions to the benefit of the bacteria. Bioinformatic analysis of the pan-genus genome predicts at least 608 orthologous groups of putative effectors. Deciphering the function of these effectors is key to understanding Legionella pathogenesis; however, the analysis is challenging. Substantial functional redundancy renders classical, phenotypic screening of single gene deletion mutants mostly ineffective. Here, I review experimental approaches that were successfully used to identify, validate and functionally characterize T4SS effectors and highlight new methods, which promise to facilitate unlocking the secrets of Legionella's extraordinary weapons arsenal.

  10. Applicability assessment of ceramic microbeads coated with hydroxyapatite-binding silver/titanium dioxide ceramic composite earthplus™ to the eradication of Legionella in rainwater storage tanks for household use.

    Science.gov (United States)

    Oana, Kozue; Kobayashi, Michiko; Yamaki, Dai; Sakurada, Tsukasa; Nagano, Noriyuki; Kawakami, Yoshiyuki

    2015-01-01

    Water environments appear to be the habitats of Legionella species. Legionellosis is considered as a preventable illness because bacterial reservoirs can be controlled and removed. Roof-harvested rainwater has attracted significant attention not only as a groundwater recharge but also as a potential alternative source of nonpotable water. We successfully developed ceramic microbeads coated with hydroxyapatite-binding silver/titanium dioxide ceramic composite earthplus™ using the thermal spraying method. The ceramic microbeads were demonstrated to have bactericidal activities against not only Legionella but also coliform and heterotrophic bacteria. Immersing the ceramic microbeads in household rainwater storage tanks was demonstrated to yield the favorable eradication of Legionella organisms. Not only rapid-acting but also long-lasting bactericidal activities of the ceramic microbead were exhibited against Legionella pneumophila. However, time-dependent attenuation of the bactericidal activities against Legionella were also noted in the sustainability appraisal experiment. Therefore, the problems to be overcome surely remain in constantly managing the Legionella-pollution by means of immersing the ceramic microbeads. The results of our investigation apparently indicate that the earthplus™-coated ceramic microbeads would become the favorable tool for Legionella measures in household rainwater storage tanks, which may become the natural reservoir for Legionella species. Our investigation would justify further research and data collection to obtain more reliable procedures to microbiologically regulate the Legionella in rainwater storage tanks.

  11. Applicability assessment of ceramic microbeads coated with hydroxyapatite-binding silver/titanium dioxide ceramic composite earthplus™ to the eradication of Legionella in rainwater storage tanks for household use

    Science.gov (United States)

    Oana, Kozue; Kobayashi, Michiko; Yamaki, Dai; Sakurada, Tsukasa; Nagano, Noriyuki; Kawakami, Yoshiyuki

    2015-01-01

    Water environments appear to be the habitats of Legionella species. Legionellosis is considered as a preventable illness because bacterial reservoirs can be controlled and removed. Roof-harvested rainwater has attracted significant attention not only as a groundwater recharge but also as a potential alternative source of nonpotable water. We successfully developed ceramic microbeads coated with hydroxyapatite-binding silver/titanium dioxide ceramic composite earthplus™ using the thermal spraying method. The ceramic microbeads were demonstrated to have bactericidal activities against not only Legionella but also coliform and heterotrophic bacteria. Immersing the ceramic microbeads in household rainwater storage tanks was demonstrated to yield the favorable eradication of Legionella organisms. Not only rapid-acting but also long-lasting bactericidal activities of the ceramic microbead were exhibited against Legionella pneumophila. However, time-dependent attenuation of the bactericidal activities against Legionella were also noted in the sustainability appraisal experiment. Therefore, the problems to be overcome surely remain in constantly managing the Legionella-pollution by means of immersing the ceramic microbeads. The results of our investigation apparently indicate that the earthplus™-coated ceramic microbeads would become the favorable tool for Legionella measures in household rainwater storage tanks, which may become the natural reservoir for Legionella species. Our investigation would justify further research and data collection to obtain more reliable procedures to microbiologically regulate the Legionella in rainwater storage tanks. PMID:26346201

  12. A Legionella Effector Disrupts Host Cytoskeletal Structure by Cleaving Actin.

    Directory of Open Access Journals (Sweden)

    Yao Liu

    2017-01-01

    Full Text Available Legionella pneumophila, the etiological agent of Legionnaires' disease, replicates intracellularly in protozoan and human hosts. Successful colonization and replication of this pathogen in host cells requires the Dot/Icm type IVB secretion system, which translocates approximately 300 effector proteins into the host cell to modulate various cellular processes. In this study, we identified RavK as a Dot/Icm substrate that targets the host cytoskeleton and reduces actin filament abundance in mammalian cells upon ectopic expression. RavK harbors an H95EXXH99 motif associated with diverse metalloproteases, which is essential for the inhibition of yeast growth and for the induction of cell rounding in HEK293T cells. We demonstrate that the actin protein itself is the cellular target of RavK and that this effector cleaves actin at a site between residues Thr351 and Phe352. Importantly, RavK-mediated actin cleavage also occurs during L. pneumophila infection. Cleavage by RavK abolishes the ability of actin to form polymers. Furthermore, an F352A mutation renders actin resistant to RavK-mediated cleavage; expression of the mutant in mammalian cells suppresses the cell rounding phenotype caused by RavK, further establishing that actin is the physiological substrate of RavK. Thus, L. pneumophila exploits components of the host cytoskeleton by multiple effectors with distinct mechanisms, highlighting the importance of modulating cellular processes governed by the actin cytoskeleton in the intracellular life cycle of this pathogen.

  13. [Genotypic variability and persistence of Legionella pulsed-field gel electrophoresis patterns in 16 cooling towers in Shanghai, China].

    Science.gov (United States)

    Chen, Ming-liang; Wang, Gang-yi; Chen, Min; Zhou, Hai-jian; Shao, Zhu-jun; Zhang, Xi; Wu, Fan

    2010-07-01

    To investigate the genotypic characteristics and persistence of Legionella pulsed-field gel electrophoresis (PFGE) patterns in 16 air-conditioner cooling towers in six different public sites of Shanghai. From May to October, continuous sampling was operated once per month in 2007. Legionella strains isolated from the 16 cooling towers were confirmed by serological and latex agglutination. PFGE was applied for the fingerprinting of the isolates, while the cluster results of PFGE were analyzed by BioNumerics software. 131 strains of Legionella were isolated, including L. pneumophila, L. bozemanae, L. micdadei and L. anisa. 52 distinguishable PFGE patterns were differentiated among the 16 cooling towers, with 37 patterns were owned by just one cooling tower, which was not shared with other cooling towers, while 15 patterns were shared by more than 2 cooling towers. All the cooling towers had ≥ 2 PFGE patterns, while in 13 cooling towers the same PFGE patterns were recovered during the six months. From June to October of 2007, 18 strains of Legionella belonging to the PFGE pattern of LPAs.SH0078 were isolated continuously from 6 cooling towers. This study demonstrated great genotypic diversity and complexity of Legionella in cooling towers. Persistence of the PFGE patterns was observed in 81.25% of the cooling towers. The PFGE pattern of LPAs. SH0078 was distributed widely, suggesting it might be the dominate strain in Shanghai.

  14. Prevalence and distribution of Legionella spp in potable water systems in Germany, risk factors associated with contamination, and effectiveness of thermal disinfection.

    Science.gov (United States)

    Kruse, Eva-Brigitta; Wehner, Arno; Wisplinghoff, Hilmar

    2016-04-01

    Worldwide, Legionella spp are a common cause of community-acquired pneumonia. Potable water systems are a main reservoir; however, exposure in the community is unknown. Water samples from 718 buildings in Germany were collected. Possible risk factors were prospectively recorded. All samples were tested for Legionella spp using cultural microbiologic methods. Samples were assigned to 1 of 5 levels of contamination. Statistical analysis was performed to determine the influence of risk factors for contamination and, in a subgroup of buildings, for unsuccessful thermal disinfection. In total, 4,482 water samples from 718 different water supply systems were analyzed. In 233 buildings (32.7%), Legionella spp were identified, 148 (63.5%) of which had a medium or higher level of contamination. The most common species was Legionella pneumophila (94%). Contamination was strongly associated with temperature in the circulation, but not with the size of the building, time of the year, or transport time to the laboratory. Thermal disinfection was successful in fewer than half of the buildings. There is relevant exposure to Legionella spp in the community. Water systems are not always up to current technical standards. Although microbiological risk assessment remains a challenge, there is a case for monitoring for Legionella spp outside of hospitals. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  15. Legionnaires' Disease Outbreak Caused by Endemic Strain of Legionella pneumophila, New York, New York, USA, 2015.

    Science.gov (United States)

    Lapierre, Pascal; Nazarian, Elizabeth; Zhu, Yan; Wroblewski, Danielle; Saylors, Amy; Passaretti, Teresa; Hughes, Scott; Tran, Anthony; Lin, Ying; Kornblum, John; Morrison, Shatavia S; Mercante, Jeffrey W; Fitzhenry, Robert; Weiss, Don; Raphael, Brian H; Varma, Jay K; Zucker, Howard A; Rakeman, Jennifer L; Musser, Kimberlee A

    2017-11-01

    During the summer of 2015, New York, New York, USA, had one of the largest and deadliest outbreaks of Legionnaires' disease in the history of the United States. A total of 138 cases and 16 deaths were linked to a single cooling tower in the South Bronx. Analysis of environmental samples and clinical isolates showed that sporadic cases of legionellosis before, during, and after the outbreak could be traced to a slowly evolving, single-ancestor strain. Detection of an ostensibly virulent Legionella strain endemic to the Bronx community suggests potential risk for future cases of legionellosis in the area. The genetic homogeneity of the Legionella population in this area might complicate investigations and interpretations of future outbreaks of Legionnaires' disease.

  16. Modelling characteristics to predict Legionella contamination risk - Surveillance of drinking water plumbing systems and identification of risk areas.

    Science.gov (United States)

    Völker, Sebastian; Schreiber, Christiane; Kistemann, Thomas

    2016-01-01

    For the surveillance of drinking water plumbing systems (DWPS) and the identification of risk factors, there is a need for an early estimation of the risk of Legionella contamination within a building, using efficient and assessable parameters to estimate hazards and to prioritize risks. The precision, accuracy and effectiveness of ways of estimating the risk of higher Legionella numbers (temperature, stagnation, pipe materials, etc.) have only rarely been empirically assessed in practice, although there is a broad consensus about the impact of these risk factors. We collected n = 807 drinking water samples from 9 buildings which had had Legionella spp. occurrences of >100 CFU/100mL within the last 12 months, and tested for Legionella spp., L. pneumophila, HPC 20°C and 36°C (culture-based). Each building was sampled for 6 months under standard operating conditions in the DWPS. We discovered high variability (up to 4 log(10) steps) in the presence of Legionella spp. (CFU/100 mL) within all buildings over a half year period as well as over the course of a day. Occurrences were significantly correlated with temperature, pipe length measures, and stagnation. Logistic regression modelling revealed three parameters (temperature after flushing until no significant changes in temperatures can be obtained, stagnation (low withdrawal, qualitatively assessed), pipe length proportion) to be the best predictors of Legionella contamination (>100 CFU/100 mL) at single outlets (precision = 66.7%; accuracy = 72.1%; F(0.5) score = 0.59). Copyright © 2015 Elsevier GmbH. All rights reserved.

  17. Investigation of Legionella Contamination in Bath Water Samples by Culture, Amoebic Co-Culture, and Real-Time Quantitative PCR Methods.

    Science.gov (United States)

    Edagawa, Akiko; Kimura, Akio; Kawabuchi-Kurata, Takako; Adachi, Shinichi; Furuhata, Katsunori; Miyamoto, Hiroshi

    2015-10-19

    We investigated Legionella contamination in bath water samples, collected from 68 bathing facilities in Japan, by culture, culture with amoebic co-culture, real-time quantitative PCR (qPCR), and real-time qPCR with amoebic co-culture. Using the conventional culture method, Legionella pneumophila was detected in 11 samples (11/68, 16.2%). Contrary to our expectation, the culture method with the amoebic co-culture technique did not increase the detection rate of Legionella (4/68, 5.9%). In contrast, a combination of the amoebic co-culture technique followed by qPCR successfully increased the detection rate (57/68, 83.8%) compared with real-time qPCR alone (46/68, 67.6%). Using real-time qPCR after culture with amoebic co-culture, more than 10-fold higher bacterial numbers were observed in 30 samples (30/68, 44.1%) compared with the same samples without co-culture. On the other hand, higher bacterial numbers were not observed after propagation by amoebae in 32 samples (32/68, 47.1%). Legionella was not detected in the remaining six samples (6/68, 8.8%), irrespective of the method. These results suggest that application of the amoebic co-culture technique prior to real-time qPCR may be useful for the sensitive detection of Legionella from bath water samples. Furthermore, a combination of amoebic co-culture and real-time qPCR might be useful to detect viable and virulent Legionella because their ability to invade and multiply within free-living amoebae is considered to correlate with their pathogenicity for humans. This is the first report evaluating the efficacy of the amoebic co-culture technique for detecting Legionella in bath water samples.

  18. Two Legionnaires' disease cases associated with industrial waste water treatment plants: a case report

    Directory of Open Access Journals (Sweden)

    Putus Tuula

    2010-12-01

    Full Text Available Abstract Background Finnish and Swedish waste water systems used by the forest industry were found to be exceptionally heavily contaminated with legionellae in 2005. Case presentation We report two cases of severe pneumonia in employees working at two separate mills in Finland in 2006. Legionella serological and urinary antigen tests were used to diagnose Legionnaires' disease in the symptomatic employees, who had worked at, or close to, waste water treatment plants. Since the findings indicated a Legionella infection, the waste water and home water systems were studied in more detail. The antibody response and Legionella urinary antigen finding of Case A indicated that the infection had been caused by Legionella pneumophila serogroup 1. Case A had been exposed to legionellae while installing a pump into a post-clarification basin at the waste water treatment plant of mill A. Both the water and sludge in the basin contained high concentrations of Legionella pneumophila serogroup 1, in addition to serogroups 3 and 13. Case B was working 200 meters downwind from a waste water treatment plant, which had an active sludge basin and cooling towers. The antibody response indicated that his disease was due to Legionella pneumophila serogroup 2. The cooling tower was the only site at the waste water treatment plant yielding that serogroup, though water in the active sludge basin yielded abundant growth of Legionella pneumophila serogroup 5 and Legionella rubrilucens. Both workers recovered from the disease. Conclusion These are the first reported cases of Legionnaires' disease in Finland associated with industrial waste water systems.

  19. Is Venice an ideal habitat for Legionella pneumophila?

    Science.gov (United States)

    Ziprani, C; Selle, V; Palazzi, B; Capretta, F; Ghio, L; Flora, M E; Baldo, V

    2012-09-01

    Legionella bacterium manifests itself in Legionnaire's disease and Pontiac fever, it is mainly found and transmitted by aerosol produced in cooling towers, water distribution plants and medical equipment, and it affects mainly elder persons in poor health. The population of Venice Local Health Unit was divided in two areas of study and the incidence of legionellosis in residents of Venice historical centre (Distretto Sanitario 1) and in residents of the mainland and coastal areas (Distretti Sanitari 2, 3, 4) was calculated. The cases were those notified to the Public Health Unit by law, and the population of residents was that of the eligible for health care in the archives of the Local Health Unit. Only cases of legionellosis in residents who had not travelled in the 10 days previous of the onset of disease, and not related to nosocomial clusters were considered. The standardized incidence ratio was then calculated and confidence interval were defined by Poisson distribution. Given the population of the two areas, 59801 in Distretto Sanitario 1 and 237555 in Distretti 2, 3, 4, the raw incidence of disease is respectively 87 per 100000 and 20 per 100000 in time 2002-2010. The standardized incidence ratio for the population of Distretto Sanitario 1 vs the remaining population is 4.3. The difference in risk of getting the disease in this two residential areas geographically very close, is probably related to the different buildings' characteristics, old and difficult to maintain in Venice historical centre.

  20. Legionnaires' disease in the renal transplant unit of "Hospital das Clinicas, FMUSP": during a five year period (1988-1993 Doença dos legionários na Unidade de Transplante Renal (UTR do Hospital das Clínicas FMUSP, no período de 1988 a 1993

    Directory of Open Access Journals (Sweden)

    Neusa Augusta de Oliveira Mazieri

    1994-06-01

    Full Text Available Several reports have related Legionella pneumophila with pneumonia in renal transplant patients, however this association has not been systematically documented in Brazil. Therefore this paper reports the incidence, by serologycal assays, of Legionella pneumophila serogroup 1 in these patients during a five year period. For this purpose sera from blood samples of 70 hospitalized patients with pneumonia from the Renal Transplant Unit of Hospital das Clinicas, FMUSP collected at the acute and convalescent phase of infection were submitted to indirect immunofluorescence assay (IFA to demonstrate anti-Legionella pneumophila serogroup 1 antibodies. Of these 70 patients studied during the period of 1988 to 1993,18 (25.71 % had significant rises in specific antibody titers for Legionella pneumophila serogroup 1. Incidence was interrupted following Hospital water decontamination procedures, with recurrence of infections after treatment interruption. In this study, the high susceptibility (25.71% of immunodepressed renal transplant patients to Legionella pneumophila serogroup 1 nosocomial infections is documented. The importance of the implementation and maintenance of water decontamination measures for prophylaxis of the infection is also clearly evident.Embora vários trabalhos tem mostrado a presença de Legionella pneumophila associado a pneumopatias infecciosas em transplantados renais, tal associação não fora antes realizado de maneira sistemática no Brasil. Os autores julgaram oportuno a determinação da incidência por comprovação sorológica da Legionella pneumophila sorogrupo 1 em transplantados renais num período de 5 anos. Para tanto amostras de soros de 70 pacientes com pneumopatia infecciosa internados na UTR do HC-FMUSP, colhidos na fase aguda e convalescente da infecção, foram submetidas à reação de imunofluo-rescência indireta para pesquisa de anticorpos anti-Legionella pneumophila sorogrupo 1. Dos 70 pacientes

  1. Life Stage-specific Proteomes of Legionella pneumophila Reveal a Highly Differential Abundance of Virulence-associated Dot/Icm effectors*

    Science.gov (United States)

    Aurass, Philipp; Gerlach, Thomas; Becher, Dörte; Voigt, Birgit; Karste, Susanne; Bernhardt, Jörg; Riedel, Katharina; Hecker, Michael; Flieger, Antje

    2016-01-01

    Major differences in the transcriptional program underlying the phenotypic switch between exponential and post-exponential growth of Legionella pneumophila were formerly described characterizing important alterations in infection capacity. Additionally, a third state is known where the bacteria transform in a viable but nonculturable state under stress, such as starvation. We here describe phase-related proteomic changes in exponential phase (E), postexponential phase (PE) bacteria, and unculturable microcosms (UNC) containing viable but nonculturable state cells, and identify phase-specific proteins. We present data on different bacterial subproteomes of E and PE, such as soluble whole cell proteins, outer membrane-associated proteins, and extracellular proteins. In total, 1368 different proteins were identified, 922 were quantified and 397 showed differential abundance in E/PE. The quantified subproteomes of soluble whole cell proteins, outer membrane-associated proteins, and extracellular proteins; 841, 55, and 77 proteins, respectively, were visualized in Voronoi treemaps. 95 proteins were quantified exclusively in E, such as cell division proteins MreC, FtsN, FtsA, and ZipA; 33 exclusively in PE, such as motility-related proteins of flagellum biogenesis FlgE, FlgK, and FliA; and 9 exclusively in unculturable microcosms soluble whole cell proteins, such as hypothetical, as well as transport/binding-, and metabolism-related proteins. A high frequency of differentially abundant or phase-exclusive proteins was observed among the 91 quantified effectors of the major virulence-associated protein secretion system Dot/Icm (> 60%). 24 were E-exclusive, such as LepA/B, YlfA, MavG, Lpg2271, and 13 were PE-exclusive, such as RalF, VipD, Lem10. The growth phase-related specific abundance of a subset of Dot/Icm virulence effectors was confirmed by means of Western blotting. We therefore conclude that many effectors are predominantly abundant at either E or PE which suggests

  2. Investigation of Legionella Contamination in Bath Water Samples by Culture, Amoebic Co-Culture, and Real-Time Quantitative PCR Methods

    Directory of Open Access Journals (Sweden)

    Akiko Edagawa

    2015-10-01

    Full Text Available We investigated Legionella contamination in bath water samples, collected from 68 bathing facilities in Japan, by culture, culture with amoebic co-culture, real-time quantitative PCR (qPCR, and real-time qPCR with amoebic co-culture. Using the conventional culture method, Legionella pneumophila was detected in 11 samples (11/68, 16.2%. Contrary to our expectation, the culture method with the amoebic co-culture technique did not increase the detection rate of Legionella (4/68, 5.9%. In contrast, a combination of the amoebic co-culture technique followed by qPCR successfully increased the detection rate (57/68, 83.8% compared with real-time qPCR alone (46/68, 67.6%. Using real-time qPCR after culture with amoebic co-culture, more than 10-fold higher bacterial numbers were observed in 30 samples (30/68, 44.1% compared with the same samples without co-culture. On the other hand, higher bacterial numbers were not observed after propagation by amoebae in 32 samples (32/68, 47.1%. Legionella was not detected in the remaining six samples (6/68, 8.8%, irrespective of the method. These results suggest that application of the amoebic co-culture technique prior to real-time qPCR may be useful for the sensitive detection of Legionella from bath water samples. Furthermore, a combination of amoebic co-culture and real-time qPCR might be useful to detect viable and virulent Legionella because their ability to invade and multiply within free-living amoebae is considered to correlate with their pathogenicity for humans. This is the first report evaluating the efficacy of the amoebic co-culture technique for detecting Legionella in bath water samples.

  3. CT features of legionella pneumonia, compared with streptococcal pneumonia. A collaborative study

    International Nuclear Information System (INIS)

    Tokuda, Hitoshi; Sakai, Fumikazu; Goto, Hajime

    2007-01-01

    Legionella pneumophila pneumonia (LPP) is of serious concern for chest physicians for its potential lethality and difficulty of diagnosis. In spite of widespread use of urine antigen detection method, it remains one of the most difficult-to-treat disease among community acquired pneumonia. We investigated CT images of 38 cases of LPP, comparing them with wide spread Streptococcus pneumoniae pneumonia (SPP). We find that sharply demarcated consolidation scattered in ground-glass opacity is the most striking and pathognomonic feature of LPP, which is rarely found in SPP. Bronchiolitis was not found in LPP, while it is a relatively common finding in SPP, which could be the second clue of differentiation of these two diseases. (author)

  4. Health risks from exposure to Legionella in reclaimed water aerosols: Toilet flushing, spray irrigation, and cooling towers.

    Science.gov (United States)

    Hamilton, Kerry A; Hamilton, Mark T; Johnson, William; Jjemba, Patrick; Bukhari, Zia; LeChevallier, Mark; Haas, Charles N

    2018-05-01

    The use of reclaimed water brings new challenges for the water industry in terms of maintaining water quality while increasing sustainability. Increased attention has been devoted to opportunistic pathogens, especially Legionella pneumophila, due to its growing importance as a portion of the waterborne disease burden in the United States. Infection occurs when a person inhales a mist containing Legionella bacteria. The top three uses for reclaimed water (cooling towers, spray irrigation, and toilet flushing) that generate aerosols were evaluated for Legionella health risks in reclaimed water using quantitative microbial risk assessment (QMRA). Risks are compared using data from nineteen United States reclaimed water utilities measured with culture-based methods, quantitative PCR (qPCR), and ethidium-monoazide-qPCR. Median toilet flushing annual infection risks exceeded 10 -4 considering multiple toilet types, while median clinical severity infection risks did not exceed this value. Sprinkler and cooling tower risks varied depending on meteorological conditions and operational characteristics such as drift eliminator performance. However, the greatest differences between risk scenarios were due to 1) the dose response model used (infection or clinical severity infection) 2) population at risk considered (residential or occupational) and 3) differences in laboratory analytical method. Theoretical setback distances necessary to achieve a median annual infection risk level of 10 -4 are proposed for spray irrigation and cooling towers. In both cooling tower and sprinkler cases, Legionella infection risks were non-trivial at potentially large setback distances, and indicate other simultaneous management practices could be needed to manage risks. The sensitivity analysis indicated that the most influential factors for variability in risks were the concentration of Legionella and aerosol partitioning and/or efficiency across all models, highlighting the importance of

  5. Current and Emerging Legionella Diagnostics for Laboratory and Outbreak Investigations

    Science.gov (United States)

    Mercante, Jeffrey W.

    2015-01-01

    SUMMARY Legionnaires' disease (LD) is an often severe and potentially fatal form of bacterial pneumonia caused by an extensive list of Legionella species. These ubiquitous freshwater and soil inhabitants cause human respiratory disease when amplified in man-made water or cooling systems and their aerosols expose a susceptible population. Treatment of sporadic cases and rapid control of LD outbreaks benefit from swift diagnosis in concert with discriminatory bacterial typing for immediate epidemiological responses. Traditional culture and serology were instrumental in describing disease incidence early in its history; currently, diagnosis of LD relies almost solely on the urinary antigen test, which captures only the dominant species and serogroup, Legionella pneumophila serogroup 1 (Lp1). This has created a diagnostic “blind spot” for LD caused by non-Lp1 strains. This review focuses on historic, current, and emerging technologies that hold promise for increasing LD diagnostic efficiency and detection rates as part of a coherent testing regimen. The importance of cooperation between epidemiologists and laboratorians for a rapid outbreak response is also illustrated in field investigations conducted by the CDC with state and local authorities. Finally, challenges facing health care professionals, building managers, and the public health community in combating LD are highlighted, and potential solutions are discussed. PMID:25567224

  6. Molecular Detection of Legionella spp. and their associations with Mycobacterium spp., Pseudomonas aeruginosa and amoeba hosts in a drinking water distribution system.

    Science.gov (United States)

    Lu, J; Struewing, I; Vereen, E; Kirby, A E; Levy, K; Moe, C; Ashbolt, N

    2016-02-01

    This study investigated waterborne opportunistic pathogens (OPs) including potential hosts, and evaluated the use of Legionella spp. for indicating microbial water quality for OPs within a full-scale operating drinking water distribution system (DWDS). To investigate the occurrence of specific microbial pathogens within a major city DWDS we examined large volume (90 l drinking water) ultrafiltration (UF) concentrates collected from six sites between February, 2012 and June, 2013. The detection frequency and concentration estimates by qPCR were: Legionella spp. (57%/85 cell equivalent, CE l(-1) ), Mycobacterium spp. (88%/324 CE l(-1) ), Pseudomonas aeruginosa (24%/2 CE l(-1) ), Vermamoeba vermiformis (24%/2 CE l(-1) ) and Acanthamoeba spp. (42%/5 cyst equivalent, CE l(-1) ). There was no detection of the following microorganisms: human faecal indicator Bacteroides (HF183), Salmonella enterica, Campylobacter spp., Escherichia coli O157:H7, Giardia intestinalis, Cryptosporidium spp. or Naegleria fowleri. There were significant correlations between the qPCR signals of Legionella spp. and Mycobacterium spp., and their potential hosts V. vermiformis and Acanthamoeba spp. Sequencing of Legionella spp. demonstrated limited diversity, with most sequences coming from two dominant groups, of which the larger dominant group was an unidentified species. Other known species including Legionella pneumophila were detected, but at low frequency. The densities of Legionella spp. and Mycobacterium spp. were generally higher (17 and 324 folds, respectively) for distal sites relative to the entry point to the DWDS. Legionella spp. occurred, had significant growth and were strongly associated with free-living amoebae (FLA) and Mycobacterium spp., suggesting that Legionella spp. could provide a useful DWDS monitoring role to indicate potential conditions for non-faecal OPs. The results provide insight into microbial pathogen detection that may aid in the monitoring of microbial water

  7. Pneumonia a Legionella – A propósito de um caso clínico

    Directory of Open Access Journals (Sweden)

    A.S. Marques

    2005-03-01

    Full Text Available Resumo: A Legionella como agente etiológico de pneumonia adquirida na comunidade (PAC é provavelmente subvalorizada, não só porque exige a utilização de métodos diagnósticos específicos como existem várias espécies e serogrupos que não são facilmente identificados pelos testes laboratoriais disponíveis. Em estudos europeus e norte-americanos, este agente é responsável por 2 a 15% de todos os casos de pneumonias adquiridas na comunidade que requerem hospitalização, figurando entre as quatro primeiras causas quando se utilizam métodos de cultura, sendo a segunda causa das que exigem tratamento em unidades de cuidados intensivos.Apresenta-se o caso clínico de um homem de 43 anos, fumador e sob corticoterapia por patologia ocular, que surge com uma pneumonia grave complicada de síndroma de dificuldade respiratória do adulto (ARDS. Necessitou de tratamento em unidade de cuidados intensivos, nomeadamente ventilação mecânica.A investigação etiológica permitiu identificar o agente responsável, a Legionella pneumophila tipo 1.Os autores fazem uma revisão desta patologia, discutindo a epidemiologia, o quadro clínico e as particularidades de diagnóstico e terapêutica.Rev Port Pneumol 2005; XI (2: 165-173 Abstract: Legionella, as a cause of community-acquired pneumonia, is probably under-recognized because the diagnosis relies on the use of specific tests as well the existence of an in-numerous species and serogroups not easily identify by the tests available.In studies from Europe and North America, it ranged from 2 to 15 percent of all community-acquired pneumonias that required hospitalisation, in the first four causes when culture methods were done and the second cause of those admitted in the intensive care units.We do a case report of 43 year-old man with history of cigarette smoking and corticosteroid therapy for a ocular disease, that presents with a

  8. High-throughput typing method to identify a non-outbreak-involved Legionella pneumophila strain colonizing the entire water supply system in the town of Rennes, France.

    Science.gov (United States)

    Sobral, D; Le Cann, P; Gerard, A; Jarraud, S; Lebeau, B; Loisy-Hamon, F; Vergnaud, G; Pourcel, C

    2011-10-01

    Two legionellosis outbreaks occurred in the city of Rennes, France, during the past decade, requiring in-depth monitoring of Legionella pneumophila in the water network and the cooling towers in the city. In order to characterize the resulting large collection of isolates, an automated low-cost typing method was developed. The multiplex capillary-based variable-number tandem repeat (VNTR) (multiple-locus VNTR analysis [MLVA]) assay requiring only one PCR amplification per isolate ensures a high level of discrimination and reduces hands-on and time requirements. In less than 2 days and using one 4-capillary apparatus, 217 environmental isolates collected between 2000 and 2009 and 5 clinical isolates obtained during outbreaks in 2000 and 2006 in Rennes were analyzed, and 15 different genotypes were identified. A large cluster of isolates with closely related genotypes and representing 77% of the population was composed exclusively of environmental isolates extracted from hot water supply systems. It was not responsible for the known Rennes epidemic cases, although strains showing a similar MLVA profile have regularly been involved in European outbreaks. The clinical isolates in Rennes had the same genotype as isolates contaminating a mall's cooling tower. This study further demonstrates that unknown environmental or genetic factors contribute to the pathogenicity of some strains. This work illustrates the potential of the high-throughput MLVA typing method to investigate the origin of legionellosis cases by allowing the systematic typing of any new isolate and inclusion of data in shared databases.

  9. Relationships between free-living protozoa, cultivable Legionella spp., and water quality characteristics in three drinking water supplies in the Caribbean.

    Science.gov (United States)

    Valster, Rinske M; Wullings, Bart A; van den Berg, Riemsdijk; van der Kooij, Dick

    2011-10-01

    The study whose results are presented here aimed at identifying free-living protozoa (FLP) and conditions favoring the growth of these organisms and cultivable Legionella spp. in drinking water supplies in a tropical region. Treated and distributed water (±30°C) of the water supplies of three Caribbean islands were sampled and investigated with molecular techniques, based on the 18S rRNA gene. The protozoan host Hartmannella vermiformis and cultivable Legionella pneumophila were observed in all three supplies. Operational taxonomic units (OTUs) with the highest similarity to the potential or candidate hosts Acanthamoeba spp., Echinamoeba exundans, E. thermarum, and an Neoparamoeba sp. were detected as well. In total, 59 OTUs of FLP were identified. The estimated protozoan richness did not differ significantly between the three supplies. In supply CA-1, the concentration of H. vermiformis correlated with the concentration of Legionella spp. and clones related to Amoebozoa predominated (82%) in the protozoan community. These observations, the low turbidity (water. The absence of H. vermiformis in most samples from supply CA-3 suggests that growth of this protozoan is limited at ATP concentrations of <1 ng liter(-1).

  10. Legionella under current legislation; Legionella onder de huidige wetgeving

    Energy Technology Data Exchange (ETDEWEB)

    Wolters, J. [Blygold Nederland Group, Houten (Netherlands)

    2010-12-15

    In 2011 the Dutch legislation concerning Legionella will be subject to change. The legislation aims to reduce the growth of the Legionella bacteria as much as possible. The alternative techniques to suppress and kill Legionella are categorised by the government in the so-called 'ladder of VROM'. New on this list is an apparatus that uses Advance Oxidation Technology, the AOT-Aqua{sup +}, which proves to be very effective and more environment-friendly. [Dutch] In 2011 wordt de Nederlandse wetgeving inzake Legionella verandert. De wetgeving is bedoeld om de groei van de Legionella bacterien zoveel mogelijk te verminderen. De alternatieve technieken waarmee Legionella kunnen worden onderdrukt of gedood zijn gecategoriseerd in de zogenaamde 'ladder van VROM'. Nieuw op deze lijst is een apparaat dat gebruik maakt van Advance Oxidatie Technology. De AOT-Aqua{sup +} blijkt zeer effectief en milieuvriendelijk te zijn.

  11. Presence of pathogenic microorganisms in power-plant cooling waters. Report for October 1, 1979-September 30, 1981

    Energy Technology Data Exchange (ETDEWEB)

    Tyndall, R.L.

    1982-10-01

    Cooling waters from eleven geographically disparate power plants were tested for the presence of Naegleria fowleri and Legionella pneumophila (LDB). Control source waters for each plant were also tested for these pathogens. Water from two of the eleven plants contained pathogenic Naegleria, and infectious Legionella were found in seven of the test sites. Pathogenic Naegleria were not found in control waters, but infectious Legionella were found in five of the eleven control source water sites. Concentrations of nitrite, sulfate, and total organic carbon correlated with the concentrations of LDB. A new species of Legionella was isolated from one of the test sites. In laboratory tests, both Acanthamoeba and Naegleria were capable of supporting the growth of Legionella pneumophila.

  12. Molecular survey of occurrence and quantity of Legionella spp., Mycobacterium spp., Pseudomonas aeruginosa and amoeba hosts in municipal drinking water storage tank sediments.

    Science.gov (United States)

    Lu, J; Struewing, I; Yelton, S; Ashbolt, N

    2015-07-01

    To examine the occurrence and quantity of potential pathogens and an indicator of microbial contamination in the sediments of municipal drinking water storage tanks (MDWSTs), given the absence of such data across the United States. Sediment samples (87 MDWST) from eighteen locations across ten states of the United States were collected and assayed by qPCR for a range of potential enteric and opportunistic microbial pathogens and a sewage-associated Bacteroides marker. Potential opportunistic pathogens dominated, with the highest detection of occurrence (per cent positive detection; average cell equivalence (CE)) being Mycobacterium spp. (88·9%; 6·7 ± 8·5 × 10(4) CE g(-1) ), followed by Legionella spp. (66·7%; 5·2 ± 5·9 × 10(3) CE g(-1) ), Pseudomonas aeruginosa (22·2%; 250 ± 880 CE g(-1) ) and Acanthamoeba spp. (38·9%; 53 ± 70 CE g(-1) ), with no detected Naegleria fowleri. Most enteric pathogens (Campylobacter jejuni, Escherichia coli 0157:H7, Salmonella enterica, Cryptosporidium parvum and Giardia duodenalis) were not detected, except for a trace signal for Campylobacter spp. There was significant correlation between the qPCR signals of Legionella spp. and Acanthamoeba spp. (R(2) = 0·61, n = 87, P = 0·0001). Diverse Legionella spp. including Leg. pneumophila, Leg. pneumophila sg1 and Leg. anisa were identified, each of which might cause legionellosis. These results imply that potential opportunistic pathogens are common within MDWST sediments and could act as a source of microbial contamination, but need downstream growth to be of potential concern. The results imply that opportunistic pathogen risks may need to be managed by regular tank cleaning or other management practices. 2015 The Society for Applied Microbiology.

  13. Relationships between Free-Living Protozoa, Cultivable Legionella spp., and Water Quality Characteristics in Three Drinking Water Supplies in the Caribbean▿†

    Science.gov (United States)

    Valster, Rinske M.; Wullings, Bart A.; van den Berg, Riemsdijk; van der Kooij, Dick

    2011-01-01

    The study whose results are presented here aimed at identifying free-living protozoa (FLP) and conditions favoring the growth of these organisms and cultivable Legionella spp. in drinking water supplies in a tropical region. Treated and distributed water (±30°C) of the water supplies of three Caribbean islands were sampled and investigated with molecular techniques, based on the 18S rRNA gene. The protozoan host Hartmannella vermiformis and cultivable Legionella pneumophila were observed in all three supplies. Operational taxonomic units (OTUs) with the highest similarity to the potential or candidate hosts Acanthamoeba spp., Echinamoeba exundans, E. thermarum, and an Neoparamoeba sp. were detected as well. In total, 59 OTUs of FLP were identified. The estimated protozoan richness did not differ significantly between the three supplies. In supply CA-1, the concentration of H. vermiformis correlated with the concentration of Legionella spp. and clones related to Amoebozoa predominated (82%) in the protozoan community. These observations, the low turbidity (water. The absence of H. vermiformis in most samples from supply CA-3 suggests that growth of this protozoan is limited at ATP concentrations of <1 ng liter−1. PMID:21873489

  14. Differential growth of Legionella pneumophila strains within a range of amoebae at various temperatures associated with in-premise plumbing

    Science.gov (United States)

    The potential effect of in-premise plumbing temperatures (24, 32, 37 and 41 °C) on the growth of five different L. pneumophila strains within free-living amoebae (Acanthamoeba polyphaga, Hartmannella vermiformis and Naegleria fowleri) was examined. Compared to controls only fed E...

  15. Multifaceted effects of synthetic TLR2 ligand and Legionella pneumophilia on Treg-mediated suppression of T cell activation

    Directory of Open Access Journals (Sweden)

    Sutmuller Roger PM

    2011-03-01

    Full Text Available Abstract Background Regulatory T cells (Treg play a crucial role in maintaining immune homeostasis and self-tolerance. The immune suppressive effects of Tregs should however be limited in case effective immunity is required against pathogens or cancer cells. We previously found that the Toll-like receptor 2 (TLR2 agonist, Pam3CysSK4, directly stimulated Tregs to expand and temporarily abrogate their suppressive capabilities. In this study, we evaluate the effect of Pam3CysSK4 and Legionella pneumophila, a natural TLR2 containing infectious agent, on effector T (Teff cells and dendritic cells (DCs individually and in co-cultures with Tregs. Results TLR2 agonists can directly provide a co-stimulatory signal inducing enhanced proliferation and cytokine production of naive CD4+ Teff cells. With respect to cytokine production, DCs appear to be most sensitive to low amounts of TLR agonists. Using wild type and TLR2-deficient cells in Treg suppression assays, we accordingly show that all cells (e.g. Treg, Teff cells and DCs contributed to overcome Treg-mediated suppression of Teff cell proliferation. Furthermore, while TLR2-stimulated Tregs readily lost their ability to suppress Teff cell proliferation, cytokine production by Teff cells was still suppressed. Similar results were obtained upon stimulation with TLR2 ligand containing bacteria, Legionella pneumophila. Conclusions These findings indicate that both synthetic and natural TLR2 agonists affect DCs, Teff cells and Treg directly, resulting in multi-modal modulation of Treg-mediated suppression of Teff cells. Moreover, Treg-mediated suppression of Teff cell proliferation is functionally distinct from suppression of cytokine secretion.

  16. Occurrence of Legionella in wastewater treatment plants linked to wastewater characteristics.

    Science.gov (United States)

    Caicedo, C; Beutel, S; Scheper, T; Rosenwinkel, K H; Nogueira, R

    2016-08-01

    In recent years, the occurrence of Legionella in wastewater treatment plants (WWTP) has often been reported. However, until now there is limited knowledge about the factors that promote Legionella's growth in such systems. The aim of this study was to investigate the chemical wastewater parameters that might be correlated to the concentration of Legionella spp. in WWTP receiving industrial effluents. For this purpose, samples were collected at different processes in three WWTP. In 100 % of the samples taken from the activated sludge tanks Legionella spp. were detected at varying concentrations (4.8 to 5.6 log GU/mL) by the quantitative real-time polymerase chain reaction method, but not by the culture method. Statistical analysis with various parameters yielded positive correlations of Legionella spp. concentration with particulate chemical oxygen demand, Kjeldahl nitrogen and protein concentration. Amino acids were quantified in wastewater and activated sludge samples at concentrations that may not support the growth of Legionella, suggesting that in activated sludge tanks this bacterium multiplied in protozoan hosts.

  17. Detection methods of Legionella in water; Detectiemethoden voor legionella in water

    Energy Technology Data Exchange (ETDEWEB)

    Schalk, J.A.C.; De Roda Husman, A.M. [Laboratorium voor zoonosen en omgevingsmicrobiologie, Rijksinstituut voor Volksgezondheid en Milieu RIVM, Bilthoven (Netherlands)

    2010-04-15

    The RIVM has compiled an overview of current and new methods for the detection of Legionella in water. The study was carried out by order of the VROM-Inspectorate with the aim of obtaining an insight into the characteristics and applications of current and newly developed methods. Legionella is omnipresent in the environment, but infection mainly results from the direct inhalation of bacteria that have multiplied in man-made water systems, such as whirlpools, cooling towers and tapwater systems. Regulations for the prevention of Legionella target the growth of Legionella in these water systems. The Waterleidingbesluit (Water Mains Decree) of 2004 requires that certain collective tapwater systems, such as those in hospitals, be checked regularly for the presence of Legionella using a standardized culture method, NEN 6265. However, the NEN 6265 method has been shown to have a number of limitations, among which are that the Legionella bacteria can be missed because they do not grow on the agar plates or are overgrown by other bacteria. New methods, including polymerase chain reaction (PCR), a Legionella-chip or amoebic-coculture, have a number of advantages over the NEN 6265 method, such as the ability to detect Legionella bacteria that are missed on the NEN 6265 agar plates. However, the new methods also have their own characteristic limitations. Some methods detect both living and dead bacterial cells, with the result that it cannot be determined if - following the eradication measure - the Legionella within an installation has actually been eliminated. Further research is required to determine if one of these new methods or a combination of methods will lead to improved detection of Legionella in tapwater systems. [Dutch] Het RIVM heeft een overzicht gemaakt van bestaande en nieuwe methoden om legionella in water aan te tonen. Dit is gemaakt in opdracht van de VROM Inspectie, die inzicht wil hebben in de kenmerken en toepassingsmogelijkheden van bestaande en nieuwe

  18. The Flagellar Regulon of Legionella—A Review

    Science.gov (United States)

    Appelt, Sandra; Heuner, Klaus

    2017-01-01

    The Legionella genus comprises more than 60 species. In particular, Legionella pneumophila is known to cause severe illnesses in humans. Legionellaceae are ubiquitous inhabitants of aquatic environments. Some Legionellaceae are motile and their motility is important to move around in habitats. Motility can be considered as a potential virulence factor as already shown for various human pathogens. The genes of the flagellar system, regulator and structural genes, are structured in hierarchical levels described as the flagellar regulon. Their expression is modulated by various environmental factors. For L. pneumophila it was shown that the expression of genes of the flagellar regulon is modulated by the actual growth phase and temperature. Especially, flagellated Legionella are known to express genes during the transmissive phase of growth that are involved in the expression of virulence traits. It has been demonstrated that the alternative sigma-28 factor is part of the link between virulence expression and motility. In the following review, the structure of the flagellar regulon of L. pneumophila is discussed and compared to other flagellar systems of different Legionella species. Recently, it has been described that Legionella micdadei and Legionella fallonii contain a second putative partial flagellar system. Hence, the report will focus on flagellated and non-flagellated Legionella strains, phylogenetic relationships, the role and function of the alternative sigma factor (FliA) and its anti-sigma-28 factor (FlgM). PMID:29104863

  19. Prevalence of Legionella pneumophila in water distribution systems in hospitals and public buildings of the Lublin region of eastern Poland

    Directory of Open Access Journals (Sweden)

    Agnieszka Sikora

    2015-05-01

    The water samples collected form the hot water supply system of hospitals and public buildings showed exceeded counts of L. pneumophila, indicating the risk of infection. The constant monitoring of water distribution systems is an important element of the control of infections caused by these organisms.

  20. Caspase-1 but Not Caspase-11 Is Required for NLRC4-Mediated Pyroptosis and Restriction of Infection by Flagellated Legionella Species in Mouse Macrophages and In Vivo.

    Science.gov (United States)

    Cerqueira, Daiane M; Pereira, Marcelo S F; Silva, Alexandre L N; Cunha, Larissa D; Zamboni, Dario S

    2015-09-01

    Gram-negative bacteria from the Legionella genus are intracellular pathogens that cause a severe form of pneumonia called Legionnaires' disease. The bacteria replicate intracellularly in macrophages, and the restriction of bacterial replication by these cells is critical for host resistance. The activation of the NAIP5/NLRC4 inflammasome, which is readily triggered in response to bacterial flagellin, is essential for the restriction of bacterial replication in murine macrophages. Once activated, this inflammasome induces pore formation and pyroptosis and facilitates the restriction of bacterial replication in macrophages. Because investigations related to the NLRC4-mediated restriction of Legionella replication were performed using mice double deficient for caspase-1 and caspase-11, we assessed the participation of caspase-1 and caspase-11 in the functions of the NLRC4 inflammasome and the restriction of Legionella replication in macrophages and in vivo. By using several species of Legionella and mice singly deficient for caspase-1 or caspase-11, we demonstrated that caspase-1 but not caspase-11 was required for pore formation, pyroptosis, and restriction of Legionella replication in macrophages and in vivo. By generating F1 mice in a mixed 129 × C57BL/6 background deficient (129 × Casp-11(-/-) ) or sufficient (129 × C57BL/6) for caspase-11 expression, we found that caspase-11 was dispensable for the restriction of Legionella pneumophila replication in macrophages and in vivo. Thus, although caspase-11 participates in flagellin-independent noncanonical activation of the NLRP3 inflammasome, it is dispensable for the activities of the NLRC4 inflammasome. In contrast, functional caspase-1 is necessary and sufficient to trigger flagellin/NLRC4-mediated restriction of Legionella spp. infection in macrophages and in vivo. Copyright © 2015 by The American Association of Immunologists, Inc.

  1. Use of Multiplex PCR for Diagnosis of Bacterial Infection Respiratory Mixed

    Directory of Open Access Journals (Sweden)

    Al-ssum, R. M.

    2010-01-01

    Full Text Available Atypical bacteria grow very slowly in culture or they do not grow at all leading to delays in detection and diagnosis. PCR multiplex was performed on template DNAs extracted from seventy three collected specimens. Thirty seven showed positive indication for the presence of bacterial infection. The incidence of Mycoplasma pneumoniae, Chlamydia pneumonia and Legionella pneumophila as a single infecting agent was 31.5%, 27.5% and 20 % respectively. Dual agent infection caused by Mycoplasma + Chlamydia, Mycoplasma + Legionella and Legionella + Chlamydia was 24%, 20% and 15% respectively. Triple agent infection caused by Legionella + Mycoplasma + Chlamydia was 17.5%. The etiology of the infection was M. pneumoniae, L. pneumophila or C. pneumoniae as a single etiology or in combination of two or three organisms.

  2. Recirculation, stagnation and ventilation: The 2014 legionella episode

    Science.gov (United States)

    Russo, Ana; Soares, Pedro M. M.; Gouveia, Célia M.; Cardoso, Rita M.; Trigo, Ricardo M.

    2017-04-01

    Legionella transmission through the atmosphere is unusual, but not unprecedented. A scientific paper published in 2006 reports a surge in Pas-de-Calais, France, in which 86 people have been infected by bacteria released by a cooling tower more than 6 km away [3]. Similarly, in Norway, in 2005, there was another case where contamination spread beyond 10 km, although more concentrated within a radius of 1 km from an industrial unit [2]. An unprecedented large Legionella outbreak occurred in November 2014 nearby Lisbon, Portugal. As of 7 November 2014, 375 individuals become hill and 12 died infected by the Legionella pneumophila bacteria, contracted by inhalation of steam droplets of contaminated water (aerosols). These droplets are so small that can carry the bacteria directly to the lungs, depositing it in the alveoli. One way of studying the propagation of legionella episodes is through the use of aerosol dispersion models. However, such approaches often require detailed 3D high resolution wind data over the region, which isn't often available for long periods. The likely impact of wind on legionella transmission can also be understood based on the analysis of special types of flow conditions such as stagnation, recirculation and ventilation [1, 4]. The Allwine and Whiteman (AW) approach constitutes a straightforward method to assess the assimilative and dispersal capacities of different airsheds [1,4], as it only requires hourly wind components. Thus, it has the advantage of not needing surface and upper air meteorological observations and a previous knowledge of the atmospheric transport and dispersion conditions. The objective of this study is to analyze if the legionella outbreak event which took place in November 2014 had extreme potential recirculation and/or stagnation characteristics. In order to accomplish the proposed objective, the AW approach was applied for a hindcast time-series covering the affected area (1989-2007) and then for an independent

  3. Active and adaptive Legionella CRISPR-Cas reveals a recurrent challenge to the pathogen.

    Science.gov (United States)

    Rao, Chitong; Guyard, Cyril; Pelaz, Carmen; Wasserscheid, Jessica; Bondy-Denomy, Joseph; Dewar, Ken; Ensminger, Alexander W

    2016-10-01

    Clustered regularly interspaced short palindromic repeats with CRISPR-associated gene (CRISPR-Cas) systems are widely recognized as critical genome defense systems that protect microbes from external threats such as bacteriophage infection. Several isolates of the intracellular pathogen Legionella pneumophila possess multiple CRISPR-Cas systems (type I-C, type I-F and type II-B), yet the targets of these systems remain unknown. With the recent observation that at least one of these systems (II-B) plays a non-canonical role in supporting intracellular replication, the possibility remained that these systems are vestigial genome defense systems co-opted for other purposes. Our data indicate that this is not the case. Using an established plasmid transformation assay, we demonstrate that type I-C, I-F and II-B CRISPR-Cas provide protection against spacer targets. We observe efficient laboratory acquisition of new spacers under 'priming' conditions, in which initially incomplete target elimination leads to the generation of new spacers and ultimate loss of the invasive DNA. Critically, we identify the first known target of L. pneumophila CRISPR-Cas: a 30 kb episome of unknown function whose interbacterial transfer is guarded against by CRISPR-Cas. We provide evidence that the element can subvert CRISPR-Cas by mutating its targeted sequences - but that primed spacer acquisition may limit this mechanism of escape. Rather than generally impinging on bacterial fitness, this element drives a host specialization event - with improved fitness in Acanthamoeba but a reduced ability to replicate in other hosts and conditions. These observations add to a growing body of evidence that host range restriction can serve as an existential threat to L. pneumophila in the wild. © 2016 The Authors Cellular Microbiology Published by John Wiley & Sons Ltd.

  4. Whole-genome sequencing for identification of the source in hospital-acquired Legionnaires' disease

    DEFF Research Database (Denmark)

    Rosendahl Madsen, A M; Holm, A; Jensen, T G

    2017-01-01

    Acquisition of Legionnaires' disease is a serious complication of hospitalization. Rapid determination of whether or not the infection is caused by strains of Legionella pneumophila in the hospital environment is crucial to avoid further cases. This study investigated the use of whole-genome sequ......Acquisition of Legionnaires' disease is a serious complication of hospitalization. Rapid determination of whether or not the infection is caused by strains of Legionella pneumophila in the hospital environment is crucial to avoid further cases. This study investigated the use of whole...

  5. Legionella in habitations

    DEFF Research Database (Denmark)

    Krøjgaard, Louise Hjelmar

    . Other have shown that more permanent, long-term water treatments, such as copper-silver ionisation, addition of chlorine dioxide or monochloramine to the portable water can be effective against Legionella colonisation, though none of the methods completely eradicated Legionella in all treatet water...

  6. [Evaluation of a Legionella outbreak emerged in a recently opening hotel].

    Science.gov (United States)

    Erdoğan, Haluk; Arslan, Hande

    2013-04-01

    samples could not be obtained from the cases, the diagnosis were not confirmed by culture but by urinary antigen test. Besides high antibody titer in single serum sample was accepted as a diagnostic marker. Additionally 26 cases who accommodated in the same hotel and presented with high fever without pneumonia were treated in the outpatient clinics of our hospital. Urinary antigen test was performed in 11 of those patients to confirm the prediagnosis of pontiac fever, however all were found negative. Likewise convalescent phase sera for the confirmation of the diagnosis by seroconversion could not be obtained since they all were foreign tourists. Investigation of water sources of the hotel revealed that the municipal drinking water network had not been connected yet and the hotel supplied water from groundwater sources. The analysis of multiple samples from multiple sites of hotel's water system indicated that the water temperature was between 35-45°C and the iron level was beyond the acceptable limits (245 µg/L) recommended for drinking water in the regulation guides. These properties were considered as the factors that enhanced the growth and survival of Legionella species. Water samples were cultivated on BCYE-_ (Buffered Charcoal Yeast Extract a-Ketoglutarate) and GVPC (Glycine-Vancomycin-Polymyxin-Cycloheximide) agar plates and 11 out of a total 13 samples yielded Legionella spp. growth. All isolates were identified as L.pneumophila serogroup 1 by specific antisera. Legionella decontamination of hotel's water system was managed by implementation of hyperchlorination method as well as superheating (> 60°C) of water. The hotel was not closed during the outbreak and cultures of water samples obtained for one year later did not yield any Legionella spp. growth. This outbreak emphasized that hotel residents are at risk for acquiring LD in the presence of a colonized water system, even in a newly constructed building. In conclusion, effective control and decontamination

  7. Technologies for Legionella Control

    Science.gov (United States)

    Presentation includes a review of new Office of Water document entitled "Technologies for Legionella Control in Premise Plumbing Systems", and discussion on ORD research projects involving Legionella and disinfection.

  8. Crystal structure of a copper-transporting PIB-type ATPase

    DEFF Research Database (Denmark)

    Gourdon, Pontus Emanuel; Liu, Xiang-Yu; Skjørringe, Tina

    2011-01-01

    Heavy-metal homeostasis and detoxification is crucial for cell viability. P-type ATPases of the class IB (PIB) are essential in these processes, actively extruding heavy metals from the cytoplasm of cells. Here we present the structure of a PIB-ATPase, a Legionella pneumophila CopA Cu(+)-ATPase, ......Heavy-metal homeostasis and detoxification is crucial for cell viability. P-type ATPases of the class IB (PIB) are essential in these processes, actively extruding heavy metals from the cytoplasm of cells. Here we present the structure of a PIB-ATPase, a Legionella pneumophila CopA Cu...

  9. Prevention of legionella. Special issue; Legionellapreventie. Themanummer

    Energy Technology Data Exchange (ETDEWEB)

    Van Wolferen, H. [TNO, Apeldoorn (Netherlands); Eland, A.; Meijer, J. [Procas, Rotterdam (Netherlands); Van den Brink, J. [Econosto Nederland, Capelle aan den IJssel (Netherlands); Tiedink, H. [Wilo Nederland, Beverwijk (Netherlands); Nuijten, O.W.W. [ISSO, Rotterdam (Netherlands); Brands, R. [Cumulus Nederland, Cuijk (Netherlands); Reijman, D.

    2008-09-15

    In seven articles attention is paid to several aspects with regard to the prevention of legionella in water heating systems: (1) an interview with an expert in this field (Will Scheffer); (2) regulations for alternative techniques; (3) experiences with collective water heaters; (4) the effect of pressure on legionella risk; (5) the prevention of legionella in cooling towers; (6) legionella safe adiabatic humidification of ambient air; (7) reducing the risk of legionella by maintenance and control. [Dutch] In 7 artikelen wordt aandacht besteed aan verschillende aspecten m.b.t. de voorkoming van legionella in verwarmingssystemen: (1) een interview met een expert op dit gebied (Will Scheffer); (2) beoordelingsrichtlijnen voor alternatieve technieken; (3) praktijkervaringen met collectieve leidingwaterinstallaties; (4) de invloed van drukverhoging op het risico van legionella; (5) legionellapreventie in koeltorens; (6) legionellaveilige adiabatische luchtbevochtiging; en (7) het beperken van het risico op legionella door onderhoud en beheer.

  10. Legionella longbeachae and legionellosis

    Directory of Open Access Journals (Sweden)

    Gea–Izquierdo Enrique

    2012-08-01

    Full Text Available La Legionella sp. es una bacteria patógena causante de la enfermedad denominada legionelosis. Ésta presenta una mortalidad mundial relevante. El medio principal del agente biológico es el agua y la transmisión a través de agua aerosolizada. Sin embargo, el género también ha sido identificado en abonos vegetales, mezclas para tiestos y derivados; con especial atención a la especie Legionella longbeachae. Esta bacteria ha sido aislada en compost y suelos (Kubota et al 2007, Pravinkumar et al 2010, Lindsay et al 2012 así como en el medio acuoso (Wang et al 2011. Lo cierto es que Legionella longbeachae es la responsable de un aumento mundial en el número de casos registrados de legionelosis, así como de brotes esporádicos en personas que han manipulado compost o tierra para jardinería (Whiley & Bentham 2011; adquiriendo importancia en determinados países (Amodeo et al 2010. En el estudio de legionellae algunos autores (Travis et al 2012 han descrito la particularidad de la presencia en suelo húmedo de multitud de especies de Legionella y no, como cabría esperar, Legionella longbeachae. Esto merece una reflexión en la estimación de un nuevo hábitat para las especies de Legionella (Velonakis et al 2010 y su implicación en el campo de la Salud Pública, sin olvidar la consideración de las limitaciones inherentes a los trabajos. De hecho, la etiología específica del agente propone una visión particular en su estudio, así como el posible planteamiento de una vía diferente en la transmisión de la bacteria.

  11. 'Gatekeeper' unit defeats legionella.

    Science.gov (United States)

    Wolters, Jo

    2007-03-01

    Legionella presents an ongoing cause for concern in any sector where duty of care responsibilities prevail. Jo Wolters, microbiologist and sector head of TA-Aqua+ at Tour & Andersson, describes a recently developed method of legionella prevention and control.

  12. [Outbreak of Legionnaires' disease in a restaurant in the Community of Madrid, Spain].

    Science.gov (United States)

    Abad Sanz, Isabel; Velasco Rodríguez, Manuel José; Marín Riaño, María Eugenia; Pérez Alonso, Jesús; Muñoz Guadalajara, María Del Carmen; Jodra Trillo, Enrique

    2014-10-01

    on June 27, 2012, 46 cases of community- acquired Legionnaires'disease were detected in the Public Health Service area 8 of the Community of Madrid. All of them had been in the same restaurant of the city of Móstoles within the incubation period of the disease. this is a descriptive study. Variables studied in the patients were: demographic data, medical history, symptoms, clinical course and diagnostic tests. For qualitative variables, frequencies and percentages were calculated. For quantitative variables, mínimum, máximum and average of values were calculated. In water samples taken on risk devices, we studied chlorine concentration, pH, temperatura and presence of Legionella. Legionella pneumophila Serogrupo 1, Subgrupo Pontiac Allentown/France was isolated from the water culture from the sand filter of the outside fountain's treatment plant; this result coincided with the strain isolated from respiratory samples of 4 patients. On the other hand, in biofilm samples obtained from the champagne bucket it was detected by PCR the presence of Legionella pneumophila whose gene sequencing was identical to that found in a respiratory sample of one patient. Legionella pneumophila serogroup 1 subgroup Pontiac Allentown/France serotype 448 was isolated in water samples, and this Legionella coincided with the one isolated from respiratory samples of some patients. So, we could show the link between environmental risk factor and the disease. This link was also confirmed by genetic sequencing with PCR.

  13. Structural analyses of Legionella LepB reveal a new GAP fold that catalytically mimics eukaryotic RasGAP.

    Science.gov (United States)

    Yu, Qin; Hu, Liyan; Yao, Qing; Zhu, Yongqun; Dong, Na; Wang, Da-Cheng; Shao, Feng

    2013-06-01

    Rab GTPases are emerging targets of diverse bacterial pathogens. Here, we perform biochemical and structural analyses of LepB, a Rab GTPase-activating protein (GAP) effector from Legionella pneumophila. We map LepB GAP domain to residues 313-618 and show that the GAP domain is Rab1 specific with a catalytic activity higher than the canonical eukaryotic TBC GAP and the newly identified VirA/EspG family of bacterial RabGAP effectors. Exhaustive mutation analyses identify Arg444 as the arginine finger, but no catalytically essential glutamine residues. Crystal structures of LepB313-618 alone and the GAP domain of Legionella drancourtii LepB in complex with Rab1-GDP-AlF3 support the catalytic role of Arg444, and also further reveal a 3D architecture and a GTPase-binding mode distinct from all known GAPs. Glu449, structurally equivalent to TBC RabGAP glutamine finger in apo-LepB, undergoes a drastic movement upon Rab1 binding, which induces Rab1 Gln70 side-chain flipping towards GDP-AlF3 through a strong ionic interaction. This conformationally rearranged Gln70 acts as the catalytic cis-glutamine, therefore uncovering an unexpected RasGAP-like catalytic mechanism for LepB. Our studies highlight an extraordinary structural and catalytic diversity of RabGAPs, particularly those from bacterial pathogens.

  14. Comparative analysis of virulence traits between a Legionella feeleii strain implicated in Pontiac fever and a strain that caused Legionnaires' disease.

    Science.gov (United States)

    Wang, Changle; Saito, Mitsumasa; Tanaka, Tamami; Amako, Kazunobu; Yoshida, Shin-ichi

    2015-12-01

    Legionella strains of the same species and serogroup are known to cause Legionnaires' disease (a potentially fatal atypical pneumonia) or Pontiac fever (a mild, flu-like disease), but the bacterial factors that define these dramatic differences in pathology have not been elucidated. To gain a better understanding of these factors, we compared the characteristics of Legionella feeleii strains that were isolated from either a sample of freshwater implicated in an outbreak of Pontiac fever (ATCC 35072, serogroup 1, LfPF), or a patient with Legionnaires' disease (ATCC 38549, serogroup 2, LfLD). Growth of LfPF and LfLD in BYE broth was slower than the positive control, Legionella pneumophila strain JR32. However, LfLD grew faster than LfPF at 42 °C. After in vitro infection to J774 murine or U937 human macrophage cell lines and A549 human lung epithelial cell line, LfLD showed a higher cell infection rate, stronger internalization by host cells, and greater cytotoxicity than that of LfPF. Large amounts of IL-6 and IL-8 were secreted by human host cells after infection with LfLD, but not with LfPF. LfLD possessed mono-polar flagellum while LfPF was unflagellated. When LfLD was cultured at 25, 30 and 37 °C, the bacteria had higher motility rate at lower temperatures. Based on our results, this is the first study that showed distinct characteristics between LfPF and LfLD, which may give important leads in elucidating differences in their virulence. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Combined pericarditis and pneumonia caused by Legionella infection

    DEFF Research Database (Denmark)

    Svendsen, Jesper Hastrup; Jønsson, V; Niebuhr, U

    1987-01-01

    During a one year period acute pericarditis was diagnosed in 16 consecutive patients without acute infarction or malignancy. In two of these patients with both pericarditis and pneumonia Legionella infection was present. One case was caused by Legionella longbeachae and the other by both Legionella...... longbeachae and Legionella jordanis. When pericarditis is associated with pneumonia Legionella infection should be sought so that effective treatment with erythromycin may be started early....

  16. A case of Legionella pneumophila evaluated with CT and ultrasound.

    Science.gov (United States)

    D'Angelo, Alessio; De Simone, Chiara; Pagnottella, Marco; Rossi, Stefano; Pepe, Raffaele; Ruggieri, Giacomo; Cocco, Giulio; Schiavone, Cosima

    2017-09-01

    A 36-year-old man was admitted to the emergency department of "SS Annunziata" hospital in Chieti complaining of a sharp chest pain arisen some hours before admission. On examination, the patient looked sweaty; his vital signs showed tachycardia and augmented breath rate; sinus tachycardia and normal ventricular repolarization were observed on ECG, and no abnormalities were observed in the echoscan of the hearth. According to the clinical and electrocardiographic findings, and to previous episode of DVT in anamnesis, a thorax CT scan was performed in order to rule out pulmonary embolism. It showed an "area of parenchymal consolidation involving almost all the left lower lobe with patent bronchial structures"; given the patient's CURB 65 score, he was then admitted to the pneumology ward where empiric treatment with levofloxacin (750 mg PO once daily) was initiated. Thoracic ultrasound was performed using a multifrequency convex transducer, and the posterior left area was examined through intercostal approach, placing the patient in a sitting position. A subpleural patchy hypoechoic lesion with irregular boundaries was detected; the maximum diameter was 11 cm, and the multiple hyperechoic spots inside it (elsewhere defined as "air bronchogram") showed no Doppler signal. Given the positive result of the Legionella urinary antigen test, antibiotic treatment was switched to Levofloxacin 1000 mg PO once daily and Claritromicin 500 mg PO twice daily. After 3 days, his clinical conditions improved dramatically. Ultrasound performed after 5 days from the diagnosis showed decreased dimensions of the lesion previously identified (maximum diameter 8.25 cm) and a marked reduction of the hyperechoic spots in it. The patient was discharged in good clinical conditions, and both thorax CT scan obtained after 1 and 4 months from the diagnosis showed radiological resolution of the parenchymal consolidation. The key to ultrasound visualization of pneumonia is its contact with

  17. High Prevalence and Genetic Polymorphisms of Legionella in Natural and Man-Made Aquatic Environments in Wenzhou, China

    Directory of Open Access Journals (Sweden)

    Leyi Zhang

    2017-02-01

    Full Text Available Natural and engineered water systems are the main sources of Legionnaires’ disease. It is essential from a public health perspective to survey water environments for the existence of Legionella. To analyze the main serogroups, genotypes and pathogenicity of the pathogen, a stratified sampling method was adopted to collect water samples randomly from shower water, cooling tower water, and local public hot springs in Wenzhou, China. Suspected strains were isolated from concentrated water samples. Serum agglutination assay and real-time PCR (Polymerase chain reaction were used to identify L. pneumophila. Sequence-based typing (SBT and pulsed-field gel electrophoresis (PFGE were used to elucidate the genetic polymorphisms in the collected isolates. The intracellular growth ability of the isolates was determined through their interaction with J774 cells and plating them onto BCYE (Buffered Charcoal Yeast Extract agar plates. Overall, 25.56% (46/180 of water samples were Legionella-positive; fifty-two strains were isolated and two kinds of serogroups were co-detected from six water samples from 2015 to 2016. Bacterial concentrations ranged from 20 CFU/100 mL to 10,720 CFU/100 mL. In detail, the Legionella-positive rates of shower water, cooling tower water and hot springs water were 15.45%, 13.33%, and 62.5%, respectively. The main serogroups were LP1 (30.69% and LP3 (28.85% and all strains carried the dot gene. Among them, 52 isolates and another 10 former isolates were analyzed by PFGE. Nineteen distinct patterns were observed in 52 strains isolated from 2015 to 2016 with three patterns being observed in 10 strains isolated from 2009 to 2014. Seventy-three strains containing 52 from this study and 21 former isolates were selected for SBT analysis and divided into 25 different sequence types in 4 main clonal groups belonging to 4 homomorphic types. Ten strains were chosen to show their abilities to grow and multiply in J744 cells. Taken together

  18. Legionella confirmation in cooling tower water

    Science.gov (United States)

    Farhat, Maha; Shaheed, Raja A.; Al-Ali, Haidar H.; Al-Ghamdi, Abdullah S.; Al-Hamaqi, Ghadeer M.; Maan, Hawraa S.; Al-Mahfoodh, Zainab A.; Al-Seba, Hussain Z.

    2018-01-01

    Objectives: To investigate the presence of Legionella spp in cooling tower water. Legionella proliferation in cooling tower water has serious public health implications as it can be transmitted to humans via aerosols and cause Legionnaires’ disease. Methods: Samples of cooling tower water were collected from King Fahd Hospital of the University (KFHU) (Imam Abdulrahman Bin Faisal University, 2015/2016). The water samples were analyzed by a standard Legionella culture method, real-time polymerase chain reaction (RT-PCR), and 16S rRNA next-generation sequencing. In addition, the bacterial community composition was evaluated. Results: All samples were negative by conventional Legionella culture. In contrast, all water samples yielded positive results by real-time PCR (105 to 106 GU/L). The results of 16S rRNA next generation sequencing showed high similarity and reproducibility among the water samples. The majority of sequences were Alpha-, Beta-, and Gamma-proteobacteria, and Legionella was the predominant genus. The hydrogen-oxidizing gram-negative bacterium Hydrogenophaga was present at high abundance, indicating high metabolic activity. Sphingopyxis, which is known for its resistance to antimicrobials and as a pioneer in biofilm formation, was also detected. Conclusion: Our findings indicate that monitoring of Legionella in cooling tower water would be enhanced by use of both conventional culturing and molecular methods. PMID:29436561

  19. Characterization of Legionella Species from Watersheds in British Columbia, Canada

    Science.gov (United States)

    Peabody, Michael A.; Caravas, Jason A.; Morrison, Shatavia S.; Mercante, Jeffrey W.; Prystajecky, Natalie A.; Raphael, Brian H.

    2017-01-01

    ABSTRACT Legionella spp. present in some human-made water systems can cause Legionnaires’ disease in susceptible individuals. Although legionellae have been isolated from the natural environment, variations in the organism’s abundance over time and its relationship to aquatic microbiota are poorly understood. Here, we investigated the presence and diversity of legionellae through 16S rRNA gene amplicon and metagenomic sequencing of DNA from isolates collected from seven sites in three watersheds with varied land uses over a period of 1 year. Legionella spp. were found in all watersheds and sampling sites, comprising up to 2.1% of the bacterial community composition. The relative abundance of Legionella tended to be higher in pristine sites than in sites affected by agricultural activity. The relative abundance levels of Amoebozoa, some of which are natural hosts of legionellae, were similarly higher in pristine sites. Compared to other bacterial genera detected, Legionella had both the highest richness and highest alpha diversity. Our findings indicate that a highly diverse population of legionellae may be found in a variety of natural aquatic sources. Further characterization of these diverse natural populations of Legionella will help inform prevention and control efforts aimed at reducing the risk of Legionella colonization of built environments, which could ultimately decrease the risk of human disease. IMPORTANCE Many species of Legionella can cause Legionnaires’ disease, a significant cause of bacterial pneumonia. Legionella in human-made water systems such as cooling towers and building plumbing systems are the primary sources of Legionnaires’ disease outbreaks. In this temporal study of natural aquatic environments, Legionella relative abundance was shown to vary in watersheds associated with different land uses. Analysis of the Legionella sequences detected at these sites revealed highly diverse populations that included potentially novel

  20. [The clinical value of urinary antigen detection of Legionella pneumonia].

    Science.gov (United States)

    Jiang, Luxi; Chen, Yu; Xia, Shuyue; Ma, Jiangwei; Zhao, Hongwen; Lu, Ye; Tao, Sixu; Zhao, Li

    2015-01-01

    To investigate the clinical value of urinary antigen detection of Legionella, and to describe the clinical characteristics of Legionella pneumonia. Patients with suspected Legionella pneumonia were enrolled from the Respiratory departments of 3 tertiary hospitals in Shenyang during May 2011 to November 2013. Urinary Legionella antigen was detected for all the enrolled patients. Bacterial culture, polymerase chain reaction (PCR) for Legionella, and double Legionella antibody detection in sera were performed for each patient whose urinary antigen was positive. Patients confirmed to have Legionella pneumonia were pooled and analyzed. Totally 13 cases presenting with pneumonia were positive for Legionella by the urinary antigen method, and in one of them Legionella strain was isolated from the secretion of lower respiratory tract. PCR detection was performed in 8 patients, and 4 of them were positive. Legionella antibody detection was performed in 12 patients, and 7 of them were positive. Nine patients had a history of exposure to Legionella high-risk environments. The characteristics of the cases with Legionella pneumonia were as follows: characteristic orange sputum in 4 patients, digestive symptoms in 6, neurologic disorders in 8, hyponatremia in 10, hypoxia with oxygenation index 130) in 8 patients . Chest CT scan showed bilateral involvement in 6, ground-glass opacity combined with consolidation in 11, and moderate pleural effusion in 11 patients. Cavity and reversed halo sign were found in one case, respectively. All of the patients received fluoroquinolone treatment, and 11 patients recovered completely while 2 died of multiple organ dysfunction syndrome, one of them was complicated with secondary infection. Detection of urinary antigen of Legionella is very useful in the diagnosis of Legionella pneumonia. Attention should be paid to exposure history to the high-risk environments and multiple organ impairment when Legionella infection is suspected. Orange sputum

  1. Legionella spp. and legionellosis in southeastern Italy: disease epidemiology and environmental surveillance in community and health care facilities

    Directory of Open Access Journals (Sweden)

    Barbuti Giovanna

    2010-11-01

    Full Text Available Abstract Background Following the publication of the Italian Guidelines for the control and prevention of legionellosis an environmental and clinical surveillance has been carried out in Southeastern Italy. The aim of the study is to identify the risk factors for the disease, so allowing better programming of the necessary prevention measures. Methods During the period January 2000 - December 2009 the environmental surveillance was carried out by water sampling of 129 health care facilities (73 public and 56 private hospitals and 533 buildings within the community (63 private apartments, 305 hotels, 19 offices, 4 churches, 116 gyms, 3 swimming pools and 23 schools. Water sampling and microbiological analysis were carried out following the Italian Guidelines. From January 2005, all facilities were subject to risk analysis through the use of a standardized report; the results were classified as good (G, medium (M and bad (B. As well, all the clinical surveillance forms for legionellosis, which must be compiled by physicians and sent to the Regional Centre for Epidemiology (OER, were analyzed. Results Legionella spp. was found in 102 (79.1% health care facilities and in 238 (44.7% community buildings. The percentages for the contamination levels 10,000 cfu/L were respectively 33.1%, 53.4% and 13.5% for samples from health care facilities and 33.5%, 43.3% and 23.2% for samples from the community. Both in hospital and community environments, Legionella pneumophila serogroup (L. pn sg 2-14 was the most frequently isolate (respectively 54.8% and 40.8% of positive samples, followed by L. pn sg 1 (respectively 31.3% and 33%. The study showed a significant association between M or B score at the risk analysis and Legionella spp. positive microbiological test results (p Conclusions Our experience suggests that risk analysis and environmental microbiological surveillance should be carried out more frequently to control the environmental spread of Legionella

  2. Detectiemethoden voor legionella in water

    NARCIS (Netherlands)

    Schalk M; de Roda Husman AM; LZO; cib

    2011-01-01

    Het RIVM heeft een overzicht gemaakt van bestaande en nieuwe methoden om legionella in water aan te tonen. Dit is gemaakt in opdracht van de VROM Inspectie, die inzicht wil hebben in de kenmerken en toepassingsmogelijkheden van bestaande en nieuwe methoden.
    Legionella komt overal in het milieu

  3. Aerobiology of the built environment: Synergy between Legionella and fungi.

    Science.gov (United States)

    Alum, Absar; Isaacs, Galahad Zachariah

    2016-09-02

    The modern built environment (BE) design creates unique ecological niches ideal for the survival and mutual interaction of microbial communities. This investigation focused on the synergistic relations between Legionella and the fungal species commonly found in BEs and the impact of these synergistic relationships on the survival and transmission of Legionella. A field study was conducted to identify the types and concentrations of fungi in BEs. The fungal isolates purified from BEs were cocultured with Legionella to study their synergistic association. Cocultured Legionella cells were aerosolized in an air-tight chamber to evaluate the efficacy of ultraviolet (UV) to inactivate these cells. Aspergillus, Alternaria, and Cladosporium were the most common fungi detected in samples that tested positive for Legionella. After coculturing, Legionella cells were detected inside fungal hyphae. The microscopic observations of Legionella internalization in fungal hyphae were confirmed by molecular analyses. UV disinfection of the aerosolized Legionella cells that were cocultured with fungi indicated that fungal spores and propagules act as a shield against UV radiation. The shield effect of fungal spores on Legionella cells was quantified at >2.5 log10. This study provides the first evidence, to our knowledge, of Legionella cell presence inside fungi detected in an indoor environment. This symbiotic relationship with fungi results in longer survival of Legionella under ambient conditions and provides protection against UV rays. Copyright © 2016. Published by Elsevier Inc.

  4. Legionella (Legionnaires' Disease and Pontiac Fever): Causes and Transmission

    Science.gov (United States)

    ... are not a risk for Legionella growth. How Legionella Affects Building Water Systems and People Learn four key steps that can lead to Legionella growing in building water systems and spreading to ...

  5. Structural basis for the recruitment and activation of the Legionella phospholipase VipD by the host GTPase Rab5

    Science.gov (United States)

    Lucas, María; Gaspar, Andrew H.; Pallara, Chiara; Rojas, Adriana Lucely; Fernández-Recio, Juan; Machner, Matthias P.; Hierro, Aitor

    2014-01-01

    A challenge for microbial pathogens is to assure that their translocated effector proteins target only the correct host cell compartment during infection. The Legionella pneumophila effector vacuolar protein sorting inhibitor protein D (VipD) localizes to early endosomal membranes and alters their lipid and protein composition, thereby protecting the pathogen from endosomal fusion. This process requires the phospholipase A1 (PLA1) activity of VipD that is triggered specifically on VipD binding to the host cell GTPase Rab5, a key regulator of endosomes. Here, we present the crystal structure of VipD in complex with constitutively active Rab5 and reveal the molecular mechanism underlying PLA1 activation. An active site-obstructing loop that originates from the C-terminal domain of VipD is repositioned on Rab5 binding, thereby exposing the catalytic pocket within the N-terminal PLA1 domain. Substitution of amino acid residues located within the VipD–Rab5 interface prevented Rab5 binding and PLA1 activation and caused a failure of VipD mutant proteins to target to Rab5-enriched endosomal structures within cells. Experimental and computational analyses confirmed an extended VipD-binding interface on Rab5, explaining why this L. pneumophila effector can compete with cellular ligands for Rab5 binding. Together, our data explain how the catalytic activity of a microbial effector can be precisely linked to its subcellular localization. PMID:25114243

  6. Counting Legionella cells within single amoeba host cells

    Science.gov (United States)

    Here we present the first attempt to quantify L. pneumophila cell numbers within individual amoebae hosts that may be released into engineered water systems. The maximum numbers of culturable L. pneumophila cells grown within Acanthamoeba polyphaga and Naegleria fowleri were 134...

  7. A Culture-Proven Case of Community-Acquired Legionella Pneumonia Apparently Classified as Nosocomial: Diagnostic and Public Health Implications

    Directory of Open Access Journals (Sweden)

    Annalisa Bargellini

    2013-01-01

    Full Text Available We report a case of Legionella pneumonia in a 78-year-old patient affected by cerebellar haemangioblastoma continuously hospitalised for 24 days prior to the onset of overt symptoms. According to the established case definition, this woman should have been definitely classified as a nosocomial case (patient spending all of the ten days in hospital before onset of symptoms. Water samples from the oncology ward were negative, notably the patient’s room and the oxygen bubbler, and the revision of the case history induced us to verify possible contamination in water samples collected at home. We found that the clinical strain had identical rep-PCR fingerprint of L. pneumophila serogroup 1 isolated at home. The description of this culture-proven case of Legionnaires’ disease has major clinical, legal, and public health consequences as the complexity of hospitalised patients poses limitations to the rule-of-thumb surveillance definition of nosocomial pneumonia based on 2–10-day incubation period.

  8. The Legionella Kinase LegK2 Targets the ARP2/3 Complex To Inhibit Actin Nucleation on Phagosomes and Allow Bacterial Evasion of the Late Endocytic Pathway

    Science.gov (United States)

    Michard, Céline; Sperandio, Daniel; Baïlo, Nathalie; Pizarro-Cerdá, Javier; LeClaire, Lawrence; Chadeau-Argaud, Elise; Pombo-Grégoire, Isabel; Hervet, Eva; Vianney, Anne; Gilbert, Christophe; Faure, Mathias; Cossart, Pascale

    2015-01-01

    ABSTRACT Legionella pneumophila, the etiological agent of legionellosis, replicates within phagocytic cells. Crucial to biogenesis of the replicative vacuole is the Dot/Icm type 4 secretion system, which translocates a large number of effectors into the host cell cytosol. Among them is LegK2, a protein kinase that plays a key role in Legionella infection. Here, we identified the actin nucleator ARP2/3 complex as a target of LegK2. LegK2 phosphorylates the ARPC1B and ARP3 subunits of the ARP2/3 complex. LegK2-dependent ARP2/3 phosphorylation triggers global actin cytoskeleton remodeling in cells, and it impairs actin tail formation by Listeria monocytogenes, a well-known ARP2/3-dependent process. During infection, LegK2 is addressed to the Legionella-containing vacuole surface and inhibits actin polymerization on the phagosome, as revealed by legK2 gene inactivation. Consequently, LegK2 prevents late endosome/lysosome association with the phagosome and finally contributes to remodeling of the bacterium-containing phagosome into a replicative niche. The inhibition of actin polymerization by LegK2 and its effect on endosome trafficking are ARP2/3 dependent since it can be phenocopied by a specific chemical inhibitor of the ARP2/3 complex. Thus, LegK2-ARP2/3 interplay highlights an original mechanism of bacterial virulence with an unexpected role in local actin remodeling that allows bacteria to control vesicle trafficking in order to escape host defenses. PMID:25944859

  9. Legionella (Legionnaires' Disease and Pontiac Fever): Diagnosis

    Science.gov (United States)

    ... Search Form Controls Cancel Submit Search The CDC Legionella (Legionnaires' Disease and Pontiac Fever) Note: Javascript is ... message, please visit this page: About CDC.gov . Legionella Home About the Disease Causes, How it Spreads, & ...

  10. Trend of Legionella colonization in hospital water supply.

    Science.gov (United States)

    D'Alessandro, D; Fabiani, M; Cerquetani, F; Orsi, G B

    2015-01-01

    In many nosocomial Legionella outbreaks water distribution systems are the most frequent source of infection. Considering the hospital waterline old age, an investigation on colonization by Legionella spp was carried out in order to evaluate the pipeline system weaknesses and to implement environmental preventive measures. From 2004 to 2010, overall 97 samples from the water line were collected. The samples were analyzed according to the italian Legionella spp standard methods; water temperature, pH and residual free chlorine were determined at the time of collection. X2 test, exact-test and t-test were used to compare proportions and means. Overall 28 samples (23.7%) were positive for Legionella spp, and five of them (17.9%) exceeded the threshold level >104 cfu/L. The number of positive samples varied along the years, showing a significant increasing trend (X2 for trend = 11.5; pLegionella spp by comparison to negative ones showed a lower free chlorine concentration (0.08 mg/L vs 0.15 mg/L) and a higher water temperature (46.1° vs 42.7°). Actually the percentage of positive samples decreased significantly with the increasing in free chlorine in the water (X2 for trend = 8.53; pLegionella. All hospital buildings were colonized by Legionella spp, although 80% of samples >104 cfu/L occurred in the C-building. No cases of nosocomial legionellosis were reported during the study period. Hospital water system showed a diffuse colonization by Legionella spp, although the degree of contamination reached the threshold level (>104 cfu/L) only in a small percentage of samples, showing a substantial effectiveness of the control measures applied.

  11. Legionella spp. in dental unit waterlines.

    Science.gov (United States)

    Sedlata Juraskova, E; Sedlackova, H; Janska, J; Holy, O; Lalova, I; Matouskova, I

    2017-01-01

    To determine the current presence of Legionella spp. in the output water of dental unit waterlines (DUWLs) and examine its mitigation by disinfection at the Institute of Dentistry and Oral Sciences, Faculty of Medicine and Dentistry, Palacky University Olomouc and University Hospital Olomouc. The first stage of our survey involved collecting samples of DUWL output water from 50 dental chair units (DCUs), and 2 samples of the incoming potable water. In October 2015, a one-time disinfection (1 % Stabimed) of DUWLs was conducted. This was followed by collecting 10 control samples (survey stage 2). From the total of 50 samples (survey stage 1), 18 samples (36.0 %) tested positive for Legionella spp. Following the disinfection, nine of the ten samples no longer showed any presence of Legionella. Based on culture results, the one-time disinfection (1 % Stabimed) was effective. We are unable to comment on the duration of positive effect of disinfection on the occurrence of Legionella spp. in the outlet water. It was a one-time survey (Tab. 2, Ref. 32).

  12. Vectorial role of Acanthamoeba in Legionella propagation in water for human use.

    Science.gov (United States)

    Magnet, A; Peralta, R H S; Gomes, T S; Izquierdo, F; Fernandez-Vadillo, C; Galvan, A L; Pozuelo, M J; Pelaz, C; Fenoy, S; Del Águila, C

    2015-02-01

    Legionella spp. is the causative agent of Legionnaires' disease and is transmitted through aerosols emanating from man-made water systems. Legionella resistance to water treatments has been related to its association with environmental amoebae such as Acanthamoeba. Due to the high presence of this protozoon in Spain and the high rate of notification of Legionnaires' disease of this country, the aims of this work were to study the coexistence of these bacteria and protozoa in water as well as their interaction. The usefulness of Acanthamoeba co-culture for the isolation of environmental Legionella was also studied. For this purpose, 70 water samples were collected in 2011 from three Drinking Water Treatment Plants, three Wastewater Treatment Plants and five Natural Pools in Spain. Acanthamoeba was found by PCR in 87.1% (61/70) samples and, by culture in 85.7% (60/70) samples. Legionella was detected by PCR in 58.6% (41/70) of water samples, in 5.7% (4/70) by agar culture and 75.7% (53/70) by Acanthamoeba co-culture. From the 54 Acanthamoeba water isolates, Legionella was detected in 43 of them independently of Acanthamoeba's genotype (T3, T4 and T11). Legionella feeleii, Legionella birminghamiensis, Legionella gresilensis/berliardensis, Legionella fairfieldensis, Legionella drozanski and Legionella falloni were identified. In conclusion, our results showed that environmental Acanthamoeba is infected by Legionella to a high percentage, and due to its ubiquity, high resistance and its pathogenic potential per se, new methods for its elimination should be studied. Also, the high effectivity of Acanthamoeba co-culture for Legionella detection has been shown. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. The Legionella micdadei flagellin

    DEFF Research Database (Denmark)

    Bangsborg, Jette Marie; Hindersson, P; Shand, G

    1995-01-01

    To study the structure and function of the Legionella flagellum, we screened a genomic L. micdadei library in Escherichia coli for expression of the flagellin (Fla) subunit. One recombinant clone, JM105 (pHI5588), producing a truncated Fla protein of 40.5 kDa was identified. The plasmid pHI5588...... shared a high degree of homology with other flagellin genes in the amino- and carboxy termini, whereas the central region was found to be nonconserved. The fla sequence will facilitate the cloning of Fla proteins from other Legionella species and the study of flagella in the pathogenesis of Legionnaires...

  14. An unusual case of Legionellosis.

    LENUS (Irish Health Repository)

    Prior, A R

    2011-03-01

    Legionella species is a common cause of community-acquired pneumonia. However disease due to L. pneumophila serogroup 13 is rare and has not previously been reported in Ireland. It may not be detected by routine Legionella antigen and antibody kits. Due to these limitations, early culture should be considered when legionellosis is suspected. The potential therapeutic benefit of quinolones in the management of this disease is also illustrated.

  15. Confirmed and Potential Sources of Legionella Reviewed

    NARCIS (Netherlands)

    van Heijnsbergen, Eri; Schalk, Johanna A C; Euser, Sjoerd M; Brandsema, Petra S; den Boer, Jeroen W; de Roda Husman, Ana Maria|info:eu-repo/dai/nl/139498281

    2015-01-01

    Legionella bacteria are ubiquitous in natural matrices and man-made systems. However, it is not always clear if these reservoirs can act as source of infection resulting in cases of Legionnaires' disease. This review provides an overview of reservoirs of Legionella reported in the literature, other

  16. Eliminating Legionella by inhibiting BCL-XL to induce macrophage apoptosis.

    Science.gov (United States)

    Speir, Mary; Lawlor, Kate E; Glaser, Stefan P; Abraham, Gilu; Chow, Seong; Vogrin, Adam; Schulze, Keith E; Schuelein, Ralf; O'Reilly, Lorraine A; Mason, Kylie; Hartland, Elizabeth L; Lithgow, Trevor; Strasser, Andreas; Lessene, Guillaume; Huang, David C S; Vince, James E; Naderer, Thomas

    2016-02-24

    Human pathogenic Legionella replicate in alveolar macrophages and cause a potentially lethal form of pneumonia known as Legionnaires' disease(1). Here, we have identified a host-directed therapeutic approach to eliminate intracellular Legionella infections. We demonstrate that the genetic deletion, or pharmacological inhibition, of the host cell pro-survival protein BCL-XL induces intrinsic apoptosis of macrophages infected with virulent Legionella strains, thereby abrogating Legionella replication. BCL-XL is essential for the survival of Legionella-infected macrophages due to bacterial inhibition of host-cell protein synthesis, resulting in reduced levels of the short-lived, related BCL-2 pro-survival family member, MCL-1. Consequently, a single dose of a BCL-XL-targeted BH3-mimetic therapy, or myeloid cell-restricted deletion of BCL-XL, limits Legionella replication and prevents lethal lung infections in mice. These results indicate that repurposing BH3-mimetic compounds, originally developed to induce cancer cell apoptosis, may have efficacy in treating Legionnaires' and other diseases caused by intracellular microbes.

  17. Legionella (Legionnaires' Disease and Pontiac Fever): Fast Facts

    Science.gov (United States)

    ... Search Form Controls Cancel Submit Search The CDC Legionella (Legionnaires' Disease and Pontiac Fever) Note: Javascript is ... message, please visit this page: About CDC.gov . Legionella Home About the Disease Causes, How it Spreads, & ...

  18. Survey of Legionella Species Found in Thai Soil

    Directory of Open Access Journals (Sweden)

    Tatiana C. Travis

    2012-01-01

    Full Text Available Members of the Gram-negative genus Legionella are typically found in freshwater environments, with the exception of L. longbeachae, which is present in composts and potting mixes. When contaminated aerosols are inhaled, legionellosis may result, typically as either the more serious pneumonia Legionnaires’ disease or the less severe flu-like illness Pontiac fever. It is presumed that all species of the genus Legionella are capable of causing disease in humans. As a followup to a prior clinical study of legionellosis in rural Thailand, indigenous soil samples were collected proximal to cases’ homes and workplaces and tested for the presence of legionellae by culture. We obtained 115 isolates from 22/39 soil samples and used sequence-based methods to identify 12 known species of Legionella represented by 87 isolates.

  19. Hydrodynamic cavitation to prevent legionella and scaling; Hydrodynamische cavitatie voorkomt legionella en kalk

    Energy Technology Data Exchange (ETDEWEB)

    Van Baarle, D. (ed.)

    2006-03-15

    To prevent biofouling, legionella, scaling and corrosion in heat exchangers or cooling systems chemicals are added to the process and the cooling water. An alternative is the use of so-called hydrodynamic cavitation. [Dutch] Om biofouling, kalkaanslag en corrosie tegen te gaan, worden chemicalien aan proces en koelwater toegevoegd. Er is nu ook een chemicalienvrij mechanisch alternatief om legionellavorming, corrosie en kalkafzet tegen te gaan: hydrodynamische cavitatie. Door water in een vortex-stroom te leiden ontstaan er cavitatiekrachten die (legionella)bacterieen doden en CaCO{sub 3} omvormen tot filtreerbare colloiden. Doordat het in het water aanwezige kalk niet neerslaat, verbeter de prestatie van de warmtewisselaars.

  20. Estudo comparativo da apresentação clínica da pneumonia a Legionella e outras pneumonias adquiridas na comuuidade

    Directory of Open Access Journals (Sweden)

    Nieves Sopena

    1998-11-01

    Full Text Available RESUMO: A Legionella pneumophila (LP é considerada em muitos estudos como uma das três causas mais comuns de pneumonia adquirida na comunidade (2,4 e a segunda causa em termos de gravidade.O principal objectivo do presente estudo realizado no Hospital da Universidade Autónoma de Barcelona, foi comparar os diferentes aspectos clínicos, biológicos e radiológicos da Pneumonia a Legionella pneumophilla e das outras Pneumonias adquiridas oa comunidade (PAC, de modo a auxiliar o diagnóstico precoce da pneumonia a LP.Foi realizado um estudo prospectivo de 392 doentes com PAC. Procedeu-se à análise comparativa dos aspectos epidemiológicos (hospitalizações ou viagens recentes, residência próximo de escavações ou trabalhos de constrção, contacto com animais, aves, demográficos (idade e sexo, clinicos (febre, tosse, expectoração, toracalgia, dispneia, cefaleias, confusão mental, dor aboominal, náuseas, vómitos, diarreia, artromialgias, dias de evolução, antibioterapia prévia, patologiaassociada, analiticos (leucocitose, natrémia­Na, creatina Kinase-CK, aspartato aminotransferase­AST e radiológicos. Estes aspectos foram estudados em 48 doentes com PAC por LP e 125 doentes com PAC de outra etiologia (68 por Streptococcus pneumoniae, 41 por Clamydia pneumoniae, 5 por Mycoplasma pneumoniae, 4 por Coxiella burnetii, 3 por Pseudomonas aeruginosa, 2 por Haemophilus injluenzae e 2 por Nocardia.A análise unifactorial mostrou que a PAC por LP foi mais frequente hos doentes de meia idade, do sexo masculino, em saúde aparente, mas com hábitos alcoó1icos acentuados, relativamente aos doentes com PAC de outra etioçogia. Também a auseocia de resposta aos fármacos beta-lactamicos prévios, cefaleias, diarreia, hiponatrémia grave e a elevação dos níveis de creatina Kinase sérica (CK foram mais frequentes na PAC por LP, enquanto que a tosse, expectoração e a toracalgia., foram mais frequeotes na pneumonia bacteriana de outra

  1. Glycine-containing selective medium for isolation of Legionellaceae from environmental specimens.

    OpenAIRE

    Wadowsky, R M; Yee, R B

    1981-01-01

    Glycine, at a final concentration of 0.3%, has been shown to be an excellent selective agent for the isolation of Legionellaceae. Stock cultures of Legionella pneumophila were not inhibited on buffered charcoal-yeast extract agar containing the amino acid. Among the other Legionellaceae tested, only one of two strains of L. dumoffii and two of six strains of L. micdadei were appreciably inhibited. This medium permitted the isolation of L. pneumophila from environmental specimens with marked i...

  2. Clinical predictors for Legionella in patients presenting with community-acquired pneumonia to the emergency department

    Directory of Open Access Journals (Sweden)

    Frei Reno

    2009-01-01

    Full Text Available Abstract Background Legionella species cause severe forms of pneumonia with high mortality and complication rates. Accurate clinical predictors to assess the likelihood of Legionella community-acquired pneumonia (CAP in patients presenting to the emergency department are lacking. Methods We retrospectively compared clinical and laboratory data of 82 consecutive patients with Legionella CAP with 368 consecutive patients with non-Legionella CAP included in two studies at the same institution. Results In multivariate logistic regression analysis we identified six parameters, namely high body temperature (OR 1.67, p Legionella CAP. Using optimal cut off values of these six parameters, we calculated a diagnostic score for Legionella CAP. The median score was significantly higher in Legionella CAP as compared to patients without Legionella (4 (IQR 3–4 vs 2 (IQR 1–2, p Legionella pneumonia. Conversely, of the 73 patients (16% with ≥4 points, 66% of patients had Legionella CAP. Conclusion Six clinical and laboratory parameters embedded in a simple diagnostic score accurately identified patients with Legionella CAP. If validated in future studies, this score might aid in the management of suspected Legionella CAP.

  3. Legionella (Legionnaires' Disease and Pontiac Fever): Signs and Symptoms

    Science.gov (United States)

    ... Search Form Controls Cancel Submit Search The CDC Legionella (Legionnaires' Disease and Pontiac Fever) Note: Javascript is ... message, please visit this page: About CDC.gov . Legionella Home About the Disease Causes, How it Spreads, & ...

  4. BROTE DE LEGIONELOSIS EN UN RESTAURANTE DE LA COMUNIDAD DE MADRID

    Directory of Open Access Journals (Sweden)

    Isabel Abad Sanz

    2014-01-01

    Full Text Available Fundamentos: el 27 de Junio de 2012 se detectó en el Servicio de Salud Pública del Área 8 de la Comunidad de Madrid un brote de legio- nelosis con 46 personas afectadas. Todas habían estado en el mismo restaurante del municipio de Móstoles dentro del periodo de incubación de la enfermedad. El objetivo de este trabajo es describir la evolución del brote y las medidas sanitarias adoptadas durante el mismo. Métodos: se trata de un estudio descriptivo. Se estudiaron las variables demográficas de los enfermos , antecedentes patológicos, síntomas, evolución clínica y pruebas diagnósticas. Para las variables cualitativas se calcularon frecuencias y porcentajes. Para las variables cuantitativas la media, el valor mínimo y máximo. En las muestras de agua tomadas en las instalaciones de riesgo se estudió concentración de cloro, pH, temperatura y presencia de Legionella. Resultados: en el cultivo del agua del filtro de arena de la depuradora de la fuente exterior creció Legionella pneumophila Serogrupo 1, Sub-grupo Pontiac Allentown/France. Este resultado coincidió con la cepa aislada en las muestras respiratorias de 4 pacientes. Por otro lado, en las muestras de biopelícula obtenidas en la champanera se detectó por PCR la presencia de Legionella pneumophila cuya secuenciación de genes fue idéntica a la encontrada en la muestra respiratoria de un paciente. Conclusiones: se consiguió aislar Legionella pneumophila serogrupo 1 Subgrupo Pontiac Allentown/France serotipo 448 en muestras ambientales, coincidente con la Legionella aislada en muestras respiratorias de algunos pacientes, por lo que se pudo demostrar la vinculación entre el factor de riesgo ambiental y la enfermedad. Este vínculo se confirmó además por secuenciación genética realizada por PCR.

  5. Factors Stimulating Propagation of Legionellae in Cooling Tower Water

    OpenAIRE

    Yamamoto, Hiroyuki; Sugiura, Minoru; Kusunoki, Shinji; Ezaki, Takayuki; Ikedo, Masanari; Yabuuchi, Eiko

    1992-01-01

    Our survey of cooling tower water demonstrated that the highest density of legionellae, ≥104 CFU/100 ml, appeared in water containing protozoa, ≥102 MPN/100 ml, and heterotrophic bacteria, ≥106 CFU/100 ml, at water temperatures between 25 and 35°C. Viable counts of legionellae were detected even in the winter samples, and propagation, up to 105 CFU/100 ml, occurs in summer. The counts of legionellae correlated positively with increases in water temperature, pH, and protozoan counts, but not w...

  6. RARE OCCURRENCE OF HETEROTROPHIC BACTERIA WITH PATHOGENIC POTENTIAL IN POTABLE WATER

    Science.gov (United States)

    Since the discovery of Legionella pneumophila, an opportunistic pathogen that is indigenous to water, microbiologists have speculated that there may be other opportunistic pathogens among the numerous heterotrophic bacteria found in potable water. The USEPA developed a series of...

  7. Performance of four different indirect enzyme-linked immunosorbent assays (ELISAs) to detect specific IgG, IgA, and IgM in Legionnaires' disease

    DEFF Research Database (Denmark)

    Bangsborg, Jette Marie; Shand, G H; Hansen, K

    1994-01-01

    Currently recommended methods in Legionnaires' disease serology are based upon crude whole-cell antigenic preparations. To investigate whether purified antigens would perform better in a given diagnostic test for antibodies against Legionella pneumophila, we compared the performance of three...

  8. Free-living protozoa in two unchlorinated drinking water supplies identified by phylogenic analysis of 18S rRNA gene sequences

    NARCIS (Netherlands)

    Valster, R.M.; Wullings, B.A.; Bakker, G.; Smidt, H.; Kooij, van der D.

    2009-01-01

    Free-living protozoan communities in water supplies may include hosts for Legionella pneumophila and other undesired bacteria and also pathogens. This study aimed at identifying free-living protozoa in two unchlorinated groundwater supplies using cultivation-independent molecular approaches. For

  9. Annual Progress Report - Fiscal Year 1982

    Science.gov (United States)

    1982-10-01

    ien7-week old female 4ce from each strain were inoculated by the intraperitoneal (i.p.) route with 10’ GPIPID5 0 of the Nine- Mile strain of C...I.P. INOCULATION WITH 106.5 GPIPIDo OF THE 9- MILE STRAIN OF C. BURNETII, PHASE I OVERT ILLNESS AVERAGE RANGE, DEAD/ IFAa STRAIN PERCENT DURATION, DAYS...1095. 12. Mikesell, P., J. Ezzell , and G. i. Knudson. 1981. Plasmids isolated in * Legionella pneumophila and Legionella-like organisms. Infect

  10. Restriction fragment length polymorphism of rRNA genes for molecular typing of members of the family Legionellaceae

    DEFF Research Database (Denmark)

    Bangsborg, J M; Gerner-Smidt, P; Colding, H

    1995-01-01

    Typing of Legionella pneumophila remains important in the investigation of outbreaks of Legionnaires' disease and in the control of organisms contaminating hospital water. We found that the discriminatory power of a nonradioactive ribotyping method could be improved by combining results obtained ...

  11. Existence and control of Legionella bacteria in building water systems: A review.

    Science.gov (United States)

    Springston, John P; Yocavitch, Liana

    2017-02-01

    Legionellae are waterborne bacteria which are capable of causing potentially fatal Legionnaires' disease (LD), as well as Pontiac Fever. Public concern about Legionella exploded following the 1976 outbreak at the American Legion conference in Philadelphia, where 221 attendees contracted pneumonia and 34 died. Since that time, a variety of different control methods and strategies have been developed and implemented in an effort to eradicate Legionella from building water systems. Despite these efforts, the incidence of LD has been steadily increasing in the U.S. for more than a decade. Public health and occupational hygiene professionals have maintained an active debate regarding best practices for management and control of Legionella. Professional opinion remains divided with respect to the relative merits of performing routine sampling for Legionella, vs. the passive, reactive approach that has been largely embraced by public health officials and facility owners. Given the potential risks and ramifications associated with waiting to assess systems for Legionella until after disease has been identified and confirmed, a proactive approach of periodic testing for Legionella, along with proper water treatment, is the best approach to avoiding large-scale disease outbreaks.

  12. Be prepared should Legionella strike.

    Science.gov (United States)

    Steel, Andrew

    2013-03-01

    When measures to prevent Legionella fail, and a positive result is returned from the laboratory, there is an imperative to act fast to stamp infection out, but taking the right action requires a rigorous approach. So says Andrew Steel, managing director of Airmec, a provider of essential air and water services solutions. Here he explains the legal and other obligations of health estates managers in taking all possible steps to prevent a Legionella outbreak, and, when they do face one, sets out the key remedial steps, and outlines what regulators or HSE personnel will expect to see as 'evidence' that sufficient 'duty of care' has been taken.

  13. Microbiology and Epidemiology of Legionnaire's Disease.

    Science.gov (United States)

    Burillo, Almudena; Pedro-Botet, María Luisa; Bouza, Emilio

    2017-03-01

    Legionnaire's disease (LD) is the pneumonic form of legionellosis caused by aerobic gram-negative bacilli of the genus Legionella. Individuals become infected when they inhale aerosolized water droplets contaminated with Legionella species. Forty years after the identification of Legionella pneumophila as the cause of the 1976 pneumonia outbreak in a hotel in Philadelphia, we have non-culture-based diagnostic tests, effective antibiotics, and preventive measures to handle LD. With a mortality rate still around 10%, underreporting, and sporadic outbreaks, there is still much work to be done. In this article, the authors review the microbiology, laboratory diagnosis, and epidemiology of LD. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Legionella detection by culture and qPCR: Comparing apples and oranges.

    Science.gov (United States)

    Whiley, Harriet; Taylor, Michael

    2016-01-01

    Legionella spp. are the causative agent of Legionnaire's disease and an opportunistic pathogen of significant public health concern. Identification and quantification from environmental sources is crucial for identifying outbreak origins and providing sufficient information for risk assessment and disease prevention. Currently there are a range of methods for Legionella spp. quantification from environmental sources, but the two most widely used and accepted are culture and real-time polymerase chain reaction (qPCR). This paper provides a review of these two methods and outlines their advantages and limitations. Studies from the last 10 years which have concurrently used culture and qPCR to quantify Legionella spp. from environmental sources have been compiled. 26/28 studies detected Legionella at a higher rate using qPCR compared to culture, whilst only one study detected equivalent levels of Legionella spp. using both qPCR and culture. Aggregating the environmental samples from all 28 studies, 2856/3967 (72%) tested positive for the presence of Legionella spp. using qPCR and 1331/3967 (34%) using culture. The lack of correlation between methods highlights the need to develop an acceptable standardized method for quantification that is sufficient for risk assessment and management of this human pathogen.

  15. Dicty_cDB: Contig-U16281-1 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available |pid:none) Legionella pneumophila subsp. p... 59 7e-07 EF077650_1( EF077650 |pid:none) Israel...7484_1( EF177484 |pid:none) Israeli tick typhus rickettsia str... 59 7e-07 ( P20902 ) RecName: Full=Citrate

  16. ORF Alignment: NC_002942 [GENIUS II[Archive

    Lifescience Database Archive (English)

    Full Text Available NC_002942 gi|52842820 >1p3dA 3 461 10 467 e-125 ... ref|YP_096619.1| UDP-N-acetylmuramate:L-alanine ligase Mur...28672.1| ... UDP-N-acetylmuramate:L-alanine ligase MurC [Legionella ... pneumophila subsp. pne

  17. Atypical pathogens and challenges in community-acquired pneumonia

    African Journals Online (AJOL)

    Atypical organisms such as Mycoplasma pneumoniae, Chlamydia pneumoniae, and Legionella pneumophila are implicated in up to 40 percent of cases of community-acquired pneumonia. Antibiotic treatment is empiric and includes coverage for both typical and atypical organisms. Doxycycline, a fluoroquinolone with ...

  18. In vitro antimycobacterial and antilegionella activity of licochalcone A from Chinese licorice roots

    DEFF Research Database (Denmark)

    Friis-Møller, Alice; Chen, Ming; Fuursted, Kurt

    2002-01-01

    Licochalcone A, extracted and purified from Chinese licorice roots, showed in vitro inhibitory effect on human pathogenic Mycobacteria species and Legionella species. M. tuberculosis, M. bovis and BCG were inhibited by ... resistant to > 20 mg/l Legionella pneumophila (serogroups 1 - 7) and L. bozemanii, L. dumoffii, L. feelei, L. longbeacheae and L. wadsworthii were inhibited by licochalcone A 1 - 4 mg/l, whereas L. gormanii and L. micdadei were inhibited by licochalcone A 500 - 1000 mg/l. These data indicate...

  19. Legionella (Legionnaires' Disease and Pontiac Fever): History and Disease Patterns

    Science.gov (United States)

    ... Search Form Controls Cancel Submit Search The CDC Legionella (Legionnaires' Disease and Pontiac Fever) Note: Javascript is ... message, please visit this page: About CDC.gov . Legionella Home About the Disease Causes, How it Spreads, & ...

  20. Legionnaires' Disease acquired within the homes of two patients: link to the home water supply

    International Nuclear Information System (INIS)

    Stout, J.E.; Yu, V.L.; Muraca, P.

    1987-01-01

    Two patients with sporadic community-acquired legionnaires' disease are described. Legionella pneumophila was isolated from sputum specimens, and seroconversion of antibody titers was demonstrated for both patients. Legionella pneumophila was also recovered from the residential water supply of both patients. In each case, the serogroup of the environmental organism matched that of the infecting organism. In one patient, serogroup 3 was isolated - a rare cause of legionnaires' disease, and in the second case, monoclonal antibody testing confirmed that the serogroup 1 organisms isolated from sputum and residential water supply samples were identical. The incubation period of legionnaires' disease is presumed to be up to two weeks. Because of medical problems, both patients had been confined to their homes for the entire two weeks before the onset of symptoms. This is the first report that links acquisition of community-acquired legionnaires' disease to contaminated water supplies within the homes of susceptible patients

  1. Legionella Antibodies in a Danish Hospital Staff with Known Occupational Exposure

    International Nuclear Information System (INIS)

    Rudbeck, M.; Uldum, S.A.; Rudbeck, M.; Viskum, S.; Molbak, K.

    2010-01-01

    Although legionnaires' disease frequently is acquired in health care institutions, little is known about the occupational risk of Legionella infection among health care workers. The aim of the present cross-sectional study was to analyse antibody levels among exposed hospital workers and to determine the correlation between antibodies to Legionella and self-reported symptoms. The study included 258 hospital employees and a reference group of 708 healthy blood donors. Hospital workers had a higher prevalence of Legionella antibody titres (=1 : 128) than blood donors (odds ratio 3.4; 95% CI 2.4-4.8). Antibody levels were not higher among staff members at risk of frequent aerosol exposure than among less exposed employees. There was no consistent association between a history of influenza-like symptom complex and the presence of antibodies. The results indicate that hospital workers have a higher risk of Legionella infections than the general population. However, since no excess morbidity was associated with sero positivity, most Legionella infections may be asymptomatic.

  2. 'Atypical' bacteria are a common cause of community-acquired ...

    African Journals Online (AJOL)

    A prospective serological study was carried out on consecutive adult pneumonia patients from July 1987 to July 1988. Acute and convalescent sera were tested in batches for antibodies against Legionella pneumophila serogroup 1, C. pneumoniae, Chlamydia psittaci, Coxiella burnetii (phase-2 antigen) and Mycoplasma ...

  3. An in-premise model for Legionella exposure during showering events

    Science.gov (United States)

    An exposure model was constructed to predict the critical Legionella densities in an engineered water system that might result in infection from inhalation of aerosols containing the pathogen while showering. The model predicted the Legionella densities in the shower air, water ...

  4. Legionellosis: a Walk-through to Identification of the Source of Infection.

    Science.gov (United States)

    Chochlakis, Dimosthenis; Sandalakis, Vassilios; Keramarou, Maria; Tselentis, Yannis; Psaroulaki, Anna

    2017-09-01

    Although a number of human Legionnaires' disease in tourists are recorded annually in Europe, there are few cases where a direct link can be made between the infected person and the source of infection (hotel or other accommodation). We present a scheme followed in order to track down and identify the source of infection in a tourist suffering from L. pneumophila sg 5 infection, who was accommodated in seven different hotels during his holidays in the island of Crete, and we comment on various difficulties and draw-backs of the process. Water samples were collected from the seven hotels where the patient had resided and analyzed at the regional public health laboratory using cultivation and molecular tests. Of 103 water samples analyzed, 19 (18.4%) were positive for Legionella non-pneumophila and 8 (7.8%) were positive for L. pneumophila. A successful L. pneumophila sg 5 match was found between the clinical and environmental sample, which led us to the final identification of the liable hotel. Timely notification of the case, within the the European Legionnaires' Disease Surveillance Network (ELDSNet) of the partners involved, is crucial during a course of travel associated with Legionella case investigation. Moreover, the urinary antigen test alone cannot provide sufficient information for the source identification. However, acquiring clinical as well as environmental isolates for serogroup and SBT identification is highly important for the successful matching. Copyright© by the National Institute of Public Health, Prague 2017

  5. Legionella in industrial cooling towers: monitoring and control strategies.

    Science.gov (United States)

    Carducci, A; Verani, M; Battistini, R

    2010-01-01

    Legionella contamination of industrial cooling towers has been identified as the cause of sporadic cases and outbreaks of legionellosis among people living nearby. To evaluate and control Legionella contamination in industrial cooling tower water, microbiological monitoring was carried out to determine the effectiveness of the following different disinfection treatments: (i) continuous chlorine concentration of 0.01 ppm and monthly chlorine shock dosing (5 ppm) on a single cooling tower; (ii) continuous chlorine concentration of 0.4 ppm and monthly shock of biocide P3 FERROCID 8580 (BKG Water Solution) on seven towers. Legionella spp. and total bacterial count (TBC) were determined 3 days before and after each shock dose. Both strategies demonstrated that when chlorine was maintained at low levels, the Legionella count grew to levels above 10(4) CFU l(-1) while TBC still remained above 10(8 )CFU l(-1). Chlorine shock dosing was able to eliminate bacterial contamination, but only for 10-15 days. Biocide shock dosing was also insufficient to control the problem when the disinfectant concentration was administered at only one point in the plant and at the concentration of 30 ppm. On the other hand, when at a biocide concentration of 30 or 50 ppm was distributed throughout a number of points, depending on the plant hydrodynamics, Legionella counts decreased significantly and often remained below the warning limit. Moreover, the contamination of water entering the plant and the presence of sediment were also important factors for Legionella growth. For effective decontamination of outdoor industrial cooling towers, disinfectants should be distributed in a targeted way, taking into account the possible sources of contamination. The data of the research permitted to modify the procedure of disinfection for better reduce the water and aerosol contamination and consequently the exposure risk.

  6. Storage Tank Legionella and Community

    Data.gov (United States)

    U.S. Environmental Protection Agency — Storage Tank Legionella and Community. This dataset is associated with the following publication: Qin, K., I. Struewing, J. Santodomingo, D. Lytle, and J. Lu....

  7. Screening-level assays for potentially human-infectious environmental Legionella spp.

    Science.gov (United States)

    In spite of the fact that Legionella species can be isolated from nonclinical settings, there is no standard method to determine whether environmental legionellae may be infectious to humans. In this study, an in vivo murine model of pneumonia and three in vitro proliferation as...

  8. Legionella saoudiensis sp. nov., isolated from a sewage water sample.

    Science.gov (United States)

    Bajrai, Leena Hussein; Azhar, Esam Ibraheem; Yasir, Muhammad; Jardot, Priscilla; Barrassi, Lina; Raoult, Didier; La Scola, Bernard; Pagnier, Isabelle

    2016-11-01

    A Gram-stain-negative, bacilli-shaped bacterial strain, LS-1T, was isolated from a sewage water sample collected in Jeddah, Saudi Arabia. The taxonomic position of strain LS-1T was investigated using a polyphasic taxonomic approach. Phylogenetic analysis based on 16S rRNA gene sequences and those of four other genes indicated that strain LS-1T belongs to the genus Legionella in the family Legionellaceae. Regarding the 16S rRNA gene, the most closely related species are Legionella rowbothamii LLAP-6T (98.6 %) and Legionella lytica L2T (98.5 %). The mip gene sequence of strain LS-1T showed 94 % sequence similarity with that of L. lytica L2T and 93 % similarity with that of L. rowbothamii LLAP-6T. Strain LS-1T grew optimally at a temperature of 32 °C on a buffered charcoal yeast extract (BCYE) agar plate in a 5 % CO2 atmosphere and had a flagellum. The combined phylogenetic, phenotypic and genomic sequence data suggest that strain LS-1T represents a novel species of the genus Legionella, for which the name Legionella saoudiensis sp. nov. is proposed. The type strain is LS-1T (=DSM 101682T=CSUR P2101T).

  9. Structural and Functional Studies of Fatty Acyl Adenylate Ligases from E. coli and L. pneumophila

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Z.; Swaminathan, S.; Zhou, R.; Sauder, J. M.; Tonge, P. J.; Burley, S. K.

    2011-02-18

    Fatty acyl-AMP ligase (FAAL) is a new member of a family of adenylate-forming enzymes that were recently discovered in Mycobacterium tuberculosis. They are similar in sequence to fatty acyl-coenzyme A (CoA) ligases (FACLs). However, while FACLs perform a two-step catalytic reaction, AMP ligation followed by CoA ligation using ATP and CoA as cofactors, FAALs produce only the acyl adenylate and are unable to perform the second step. We report X-ray crystal structures of full-length FAAL from Escherichia coli (EcFAAL) and FAAL from Legionella pneumophila (LpFAAL) bound to acyl adenylate, determined at resolution limits of 3.0 and 1.85 {angstrom}, respectively. The structures share a larger N-terminal domain and a smaller C-terminal domain, which together resemble the previously determined structures of FAAL and FACL proteins. Our two structures occur in quite different conformations. EcFAAL adopts the adenylate-forming conformation typical of FACLs, whereas LpFAAL exhibits a unique intermediate conformation. Both EcFAAL and LpFAAL have insertion motifs that distinguish them from the FACLs. Structures of EcFAAL and LpFAAL reveal detailed interactions between this insertion motif and the interdomain hinge region and with the C-terminal domain. We suggest that the insertion motifs support sufficient interdomain motions to allow substrate binding and product release during acyl adenylate formation, but they preclude CoA binding, thereby preventing CoA ligation.

  10. Enabling fiber optic serotyping of pathogenic bacteria through improved anti-fouling functional surfaces

    International Nuclear Information System (INIS)

    Janssen, K P F; Knez, K; Spasic, D; Lammertyn, J; Vanysacker, L; Schrooten, J

    2012-01-01

    Significant research efforts are continually being directed towards the development of sensitive and accurate surface plasmon resonance biosensors for sequence specific DNA detection. These sensors hold great potential for applications in healthcare and diagnostics. However, the performance of these sensors in practical usage scenarios is often limited due to interference from the sample matrix. This work shows how the co-immobilization of glycol (PEG) diluents or ‘back filling’ of the DNA sensing layer can successfully address these problems. A novel SPR based melting assay is used for the analysis of a synthetic oligomer target as well as PCR amplified genomic DNA extracted from Legionella pneumophila. The benefits of sensing layer back filling on the assay performance are first demonstrated through melting analysis of the oligomer target and it is shown how back filling enables accurate discrimination of Legionella pneumophila serogroups directly from the PCR reaction product with complete suppression of sensor fouling. (paper)

  11. Cloning and expression of the Legionella micdadei "common antigen" in Escherichia coli

    DEFF Research Database (Denmark)

    Bangsborg, Jette Marie; Collins, M T; Høiby, N

    1989-01-01

    To study individual Legionella antigens, a Legionella micdadei genomic library in Escherichia coli SC181 was established. Partially Sau3A digested L. micdadei DNA fragments (15-25 kilobase pairs (kb] were cloned into the tetracycline resistance gene of the cosmid vector pHC79. Four thousand...... ampicillin resistant recombinants were obtained; seven hundred were screened for expression of Legionella antigens in Western blot analysis with a polyspecific E. coli-absorbed anti-L. micdadei rabbit antibody. One of the positive clones expressed a 60 kilodalton (K) antigen, which reacted strongly...... will provide important information with respect to genetic vs. antigenic relatedness among Legionellae and other Gram-negative species, as well as to CA structure and possible function....

  12. Cluster of Legionnaires' disease in a newly built block of flats, Denmark, December 2008-January 2009

    DEFF Research Database (Denmark)

    Krøjgaard, Louise Hjelmar; Krogfelt, K. A.; Albrechtsen, Hans-Jørgen

    2011-01-01

    During December 2008 to January 2009, two persons contracted Legionnaires' disease in a newly built block of flats in a suburb of Copenhagen in Denmark. Polymerase chain reaction and culture was used to diagnose Legionnaires' disease in this cluster. Isolates from both patients tested positive...... for Legionella pneumophila serogroup 1 subgroup Philadelphia sequence type 1 and the same strain was detected in hot water samples taken from the residential area indicating that the hot water supply system was the most likely source of infection. Legionella was not detected in the cold water. Two interventions...

  13. Impact of a risk management plan on Legionella contamination of dental unit water.

    Science.gov (United States)

    Leoni, Erica; Dallolio, Laura; Stagni, Francesca; Sanna, Tiziana; D'Alessandro, Giovanni; Piana, Gabriela

    2015-02-23

    The study aimed to assess the prevalence of Legionella spp. in dental unit waterlines of a dental clinic and to verify whether the microbiological parameters used as indicators of water quality were correlated with Legionella contamination. A risk management plan was subsequently implemented in the dental health care setting, in order to verify whether the adopted disinfection protocols were effective in preventing Legionella colonization. The water delivered from syringes and turbines of 63 dental units operating in a dental clinic, was monitored for counts of the heterotrophic bacteria P. aeruginosa and Legionella spp. (22 °C and 37 °C). At baseline, output water from dental units continuously treated with disinfection products was more compliant with the recommended standards than untreated and periodically treated water. However, continuous disinfection was still not able to prevent contamination by Legionella and P. aeruginosa. Legionella was isolated from 36.4%, 24.3% and 53.3% of samples from untreated, periodically and continuously treated waterlines, respectively. The standard microbiological parameters used as indicators of water quality proved to be unreliable as predictors of the presence of Legionella, whose source was identified as the tap water used to supply the dental units. The adoption of control measures, including the use of deionized water in supplying the dental unit waterlines and the application of a combined protocol of continuous and periodic disinfection, with different active products for the different devices, resulted in good control of Legionella contamination. The efficacy of the measures adopted was mainly linked to the strict adherence to the planned protocols, which placed particular stress on staff training and ongoing environmental monitoring.

  14. Frequency of legionella contamination in conditional & water distribution systems of Tehran hospitals

    Directory of Open Access Journals (Sweden)

    Davod Esmaieli

    2008-09-01

    Full Text Available Background: Legionella species are ubiquitous in natural aquatic environments, capable of existing in waters with varied temperatures, PH levels, and nutrient and oxygen contents. Of 49 known legionella species, 20 species have been linked to pneumonia in humans. Contamination by legionella has occurred in the distribution systems of many hospitals. Aerosol-generating systems such as faucets, showerheads, cooling towers, and nebulizers are responsible for their transmission from water to air. Methods: A total of 113 water samples were gathered from different wards of 32 hospitals in different geographical regions of Tehran city. These samples were concentrated by filtration, treated with the acid and temperature buffers, and isolated on a BCYE agar culture medium. Results: A total of 22 hospitals out of 33 (26.5% were contaminated by legionella species, and 30 samples (26.5% out of 113 were positive. Chlorine concentration and pH level of the water samples were 0.18-2.2 mg/l and 6.6-7.6, respectively. Conclusion: The high rate of waste water contamination in Tehran hospitals with Legionella indicates the resistance of this microorganism to chlorine and other disinfectants, or inadequate disinfection process, representing the insufficiency of the current decontamination of hospital water distribution system. Thus identifying legionella species and their controlling in water distribution system of hospitals is of great importance.

  15. El hospital ante un brote prolongado de legionelosis The hospital faced with a prolonged Legionella outbreak

    Directory of Open Access Journals (Sweden)

    Juan Antonio Fernández

    2004-08-01

    Full Text Available Objetivo: Describir los recursos asistenciales utilizados en pacientes hospitalizados por neumonía por Legionella durante un brote ocurrido en Alcoy y compararlos con los empleados en otras neumonías. Métodos y resultados: Mediante un protocolo, se analiza y compara a 177 pacientes con neumonía por Legionella con 180 pacientes ingresados por otras neumonías, y se describe su tratamiento y los recursos empleados. La claritromicina fue el antibiótico más utilizado en ambos grupos. La estancia hospitalaria fue similar, pero los requerimientos de ventilación mecánica y cuidados intensivos fueron superiores para Legionella. La hospitalización domiciliaria se utilizó con éxito en un 15,6% de los pacientes con Legionella y en un 11,3% de los demás. El uso de oxigenoterapia domiciliaria al alta fue menor para Legionella (7,8% que para el resto de neumonías (16,7%. Conclusiones: Se destaca la mayor necesidad de ventilación mecánica en la neumonía por Legionella y los buenos resultados de la hospitalización domiciliaria dentro de los nuevos sistemas de gestión.Objective: To describe the health resources used in patients hospitalized with Legionella pneumonia during an outbreak of Legionnaire's disease in Alcoy (Spain, and to compare them with those used in other forms of pneumonia. Methods and results: Using a clinical protocol, 177 Legionella pneumonia patients were compared with 180 patients hospitalized for other types of pneumonia. Data on therapy and the resources used were collected. The most common antibiotic treatment in both groups was clarithromycin, but intensive care and mechanical ventilation requirements were greater in Legionella pneumonia. Home-based hospital care was successfully used in 15.6% of patients with Legionella pneumonia and in 11.3% of those with other types of pneumonia. Home oxygen therapy after discharge was less frequent in the Legionella pneumonia group (7.8% than in the group with non-Legionella

  16. Conventional and Alternative Disinfection Methods of Legionella in Water Distribution Systems – Review

    Directory of Open Access Journals (Sweden)

    Pūle Daina

    2016-12-01

    Full Text Available Prevalence of Legionella in drinking water distribution systems is a widespread problem. Outbreaks of Legionella caused diseases occur despite various disinfectants are used in order to control Legionella. Conventional methods like thermal disinfection, silver/copper ionization, ultraviolet irradiation or chlorine-based disinfection have not been effective in the long term for control of biofilm bacteria. Therefore, research to develop more effective disinfection methods is still necessary.

  17. Legionella shows a diverse secondary metabolism dependent on a broad spectrum Sfp-type phosphopantetheinyl transferase

    Directory of Open Access Journals (Sweden)

    Nicholas J. Tobias

    2016-11-01

    Full Text Available Several members of the genus Legionella cause Legionnaires’ disease, a potentially debilitating form of pneumonia. Studies frequently focus on the abundant number of virulence factors present in this genus. However, what is often overlooked is the role of secondary metabolites from Legionella. Following whole genome sequencing, we assembled and annotated the Legionella parisiensis DSM 19216 genome. Together with 14 other members of the Legionella, we performed comparative genomics and analysed the secondary metabolite potential of each strain. We found that Legionella contains a huge variety of biosynthetic gene clusters (BGCs that are potentially making a significant number of novel natural products with undefined function. Surprisingly, only a single Sfp-like phosphopantetheinyl transferase is found in all Legionella strains analyzed that might be responsible for the activation of all carrier proteins in primary (fatty acid biosynthesis and secondary metabolism (polyketide and non-ribosomal peptide synthesis. Using conserved active site motifs, we predict some novel compounds that are probably involved in cell-cell communication, differing to known communication systems. We identify several gene clusters, which may represent novel signaling mechanisms and demonstrate the natural product potential of Legionella.

  18. Legionella jamestowniensis fatal pneumonia in an immunosuppressed man.

    Science.gov (United States)

    Edelstein, Paul H

    2017-01-01

    A fatal case of Legionnaires' disease caused by Legionella jamestowniensis is reported in a severely immunocompromised patient with metastatic hepatocellular carcinoma, and liver and kidney transplants. L. jamestowniensis was cultured from two separate respiratory tract specimens and a PCR test for Legionella species was also positive from the same specimens. This is apparently the first reported case of human infection caused by L. jamestowniensis. Copyright © 2016 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  19. Seeing red; the development of pON.mCherry, a broad-host range constitutive expression plasmid for Gram-negative bacteria.

    Directory of Open Access Journals (Sweden)

    Michael J Gebhardt

    Full Text Available The development of plasmid-mediated gene expression control in bacteria revolutionized the field of bacteriology. Many of these expression control systems rely on the addition of small molecules, generally metabolites or non-metabolized analogs thereof, to the growth medium to induce expression of the genes of interest. The paradigmatic example of an expression control system is the lac system from Escherichia coli, which typically relies on the Ptac promoter and the Lac repressor, LacI. In many cases, however, constitutive gene expression is desired, and other experimental approaches require the coordinated control of multiple genes. While multiple systems have been developed for use in E. coli and its close relatives, the utility and/or functionality of these tools does not always translate to other species. For example, for the Gram-negative pathogen, Legionella pneumophila, a causative agent of Legionnaires' Disease, the aforementioned Ptac system represents the only well-established expression control system. In order to enhance the tools available to study bacterial gene expression in L. pneumophila, we developed a plasmid, pON.mCherry, which confers constitutive gene expression from a mutagenized LacI binding site. We demonstrate that pON.mCherry neither interferes with other plasmids harboring an intact LacI-Ptac expression system nor alters the growth of Legionella species during intracellular growth. Furthermore, the broad-host range plasmid backbone of pON.mCherry allows constitutive gene expression in a wide variety of Gram-negative bacterial species, making pON.mCherry a useful tool for the greater research community.

  20. Dicty_cDB: Contig-U15144-1 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available 46 CR628337_2246( CR628337 |pid:none) Legionella pneumophila str. Len... 176 2e-46 AY692351_1( AY692351 |pid:none) Uncultured soil...103 4e-21 AY692350_1( AY692350 |pid:none) Uncultured soil bacterium clone RC... 103 4e-21 AY077581_1( AY0775

  1. A cluster of cases of nosocomial legionnaires disease linked to a contaminated hospital decorative water fountain.

    Science.gov (United States)

    Palmore, Tara N; Stock, Frida; White, Margaret; Bordner, MaryAnn; Michelin, Angela; Bennett, John E; Murray, Patrick R; Henderson, David K

    2009-08-01

    Nosocomial outbreaks of Legionnaires disease have been linked to contaminated water in hospitals. Immunocompromised patients are particularly vulnerable and, when infected, have a high mortality rate. We report the investigation of a cluster of cases of nosocomial pneumonia attributable to Legionella pneumophila serogroup 1 that occurred among patients on our stem cell transplantation unit. We conducted a record review to identify common points of potential exposure, followed by environmental and water sampling for Legionella species from those sources. We used an air sampler to in an attempt to detect aerosolized Legionella and pulsed-field gel electrophoresis to compare clinical and environmental isolates. The most likely sources identified were the water supply in the patients' rooms and a decorative fountain in the radiation oncology suite. Samples from the patients' rooms did not grow Legionella species. Cultures of the fountain, which had been restarted 4 months earlier after being shut off for 5 months, yielded L. pneumophila serogroup 1. The isolates from both patients and the fountain were identical by pulsed-field gel electrophoresis. Both patients developed pneumonia within 10 days of completing radiation therapy, and each reported having observed the fountain at close range. Both patients' infections were identified early and treated promptly, and both recovered. This cluster was caused by contamination of a decorative fountain despite its being equipped with a filter and ozone generator. Fountains are a potential source of nosocomial Legionnaires disease despite standard maintenance and sanitizing measures. In our opinion, fountains present unacceptable risk in hospitals serving immunocompromised patients.

  2. Comparing methods of determining Legionella spp. in complex water matrices.

    Science.gov (United States)

    Díaz-Flores, Álvaro; Montero, Juan Carlos; Castro, Francisco Javier; Alejandres, Eva María; Bayón, Carmen; Solís, Inmaculada; Fernández-Lafuente, Roberto; Rodríguez, Guillermo

    2015-04-29

    Legionella testing conducted at environmental laboratories plays an essential role in assessing the risk of disease transmission associated with water systems. However, drawbacks of culture-based methodology used for Legionella enumeration can have great impact on the results and interpretation which together can lead to underestimation of the actual risk. Up to 20% of the samples analysed by these laboratories produced inconclusive results, making effective risk management impossible. Overgrowth of competing microbiota was reported as an important factor for culture failure. For quantitative polymerase chain reaction (qPCR), the interpretation of the results from the environmental samples still remains a challenge. Inhibitors may cause up to 10% of inconclusive results. This study compared a quantitative method based on immunomagnetic separation (IMS method) with culture and qPCR, as a new approach to routine monitoring of Legionella. First, pilot studies evaluated the recovery and detectability of Legionella spp using an IMS method, in the presence of microbiota and biocides. The IMS method results were not affected by microbiota while culture counts were significantly reduced (1.4 log) or negative in the same samples. Damage by biocides of viable Legionella was detected by the IMS method. Secondly, a total of 65 water samples were assayed by all three techniques (culture, qPCR and the IMS method). Of these, 27 (41.5%) were recorded as positive by at least one test. Legionella spp was detected by culture in 7 (25.9%) of the 27 samples. Eighteen (66.7%) of the 27 samples were positive by the IMS method, thirteen of them reporting counts below 10(3) colony forming units per liter (CFU l(-1)), six presented interfering microbiota and three presented PCR inhibition. Of the 65 water samples, 24 presented interfering microbiota by culture and 8 presented partial or complete inhibition of the PCR reaction. So the rate of inconclusive results of culture and PCR was 36

  3. Improving the Diagnosis of Legionella Pneumonia within a Healthcare System through a Systematic Consultation and Testing Program.

    Science.gov (United States)

    Decker, Brooke K; Harris, Patricia L; Muder, Robert R; Hong, Jae H; Singh, Nina; Sonel, Ali F; Clancy, Cornelius J

    2016-08-01

    Legionella testing is not recommended for all patients with pneumonia, but rather for particular patient subgroups. As a result, the overall incidence of Legionella pneumonia may be underestimated. To determine the incidence of Legionella pneumonia in a veteran population in an endemic area after introduction of a systematic infectious diseases consultation and testing program. In response to a 2011-2012 outbreak, the VA Pittsburgh Healthcare System mandated infectious diseases consultations and testing for Legionella by urine antigen and sputum culture in all patients with pneumonia. Between January 2013 and December 2015, 1,579 cases of pneumonia were identified. The incidence of pneumonia was 788/100,000 veterans per year, including 352/100,000 veterans per year and 436/100,000 veterans per year with community-associated pneumonia (CAP) and health care-associated pneumonia, respectively. Ninety-eight percent of patients with suspected pneumonia were tested for Legionella by at least one method. Legionella accounted for 1% of pneumonia cases (n = 16), including 1.7% (12/706) and 0.6% (4/873) of CAP and health care-associated pneumonia, respectively. The yearly incidences of Legionella pneumonia and Legionella CAP were 7.99 and 5.99/100,000 veterans, respectively. The sensitivities of urine antigen and sputum culture were 81% and 60%, respectively; the specificity of urine antigen was >99.97%. Urine antigen testing and Legionella cultures increased by 65% and 330%, respectively, after introduction of our program. Systematic testing of veterans in an endemic area revealed a higher incidence of Legionella pneumonia and CAP than previously reported. Widespread urine antigen testing was not limited by false positivity.

  4. Moxifloxacin pharmacokinetic profile and efficacy evaluation in empiric treatment of community-acquired pneumonia

    DEFF Research Database (Denmark)

    Öbrink-Hansen, Kristina; Hardlei, Tore Forsingdal; Brock, Birgitte

    2015-01-01

    for each patient were evaluated against epidemiological cutoff MIC values for Streptococcus pneumoniae, Haemophilus influenzae, and Legionella pneumophila. PK-PD targets adopted were a Cmax/MIC of ≥12.2 for all pathogens, an fAUC0-24/MIC of >34 for S. pneumoniae, and an fAUC0-24/MIC of >75 for H...

  5. Pneumonia Atipikal

    OpenAIRE

    Budastra I Nyoman; Siadi Purniti Putu; Subanada Ida Bagus

    2016-01-01

    Pneumonia atipikal adalah pneumonia yang disebabkan oleh mikroorganisme yang tidak dapat diidentifikasi dengan teknik diagnostik standar pneumonia pada umumnya dan tidak menunjukkan respon terhadap antibiotik b-laktam. Mikroorganisme patogen penyebab pneumonia atipikal pada umumnya adalah Mycoplasma pneumoniae, Chlamydia pneumoniae, dan Legionella pneumophila. Manifestasi klinik, pemeriksaan laboratorium dan radiologis pneumonia atipikal menunjukkan gambaran tidak spesifik. Man...

  6. Legionella feeleii: an unusual organism associated with cutaneous infection in an immunocompromised patient.

    Science.gov (United States)

    Verykiou, S; Goodhead, C; Parry, G; Meggitt, S

    2018-04-01

    We report a 23-year-old immunocompromised woman who, following cardiac transplantation, presented with an unusual cutaneous eruption. She developed a widespread pustular rash, systemic symptoms and a high temperature with raised inflammatory markers. The diagnosis was reached when a skin biopsy was cultured onto Legionella agar (buffered charcoal yeast extract) and Legionella feeleii was isolated. The patient was treated with 6 weeks of moxifloxacin and her cutaneous lesions gradually resolved. Cutaneous Legionella infections are uncommon and usually affect immunocompromised patients. © 2017 British Association of Dermatologists.

  7. Domestically Acquired Legionnaires’ Disease: Two Case Reports and a Review of the Pertinent Literature

    Directory of Open Access Journals (Sweden)

    Haluk Erdoğan

    2016-06-01

    Full Text Available Background: Legionella species may colonize in home water systems and cause Legionnaires’ disease (LD. We herein report two cases of sporadic LD associated with the solar energy-heated hot water systems of the patients’ houses. Case Report: A 60-year-old woman with chronic bronchitis and diabetes mellitus presented with a high fever, abdominal pain, and diarrhea. Physical examination revealed rales, and her chest radiograph showed a homogeneous density in the left lung. The Legionella urinary antigen test was positive, and an indirect fluorescent antibody test revealed a serum antibody titer of 1/520 for L. pneumophila serogroup 1. In the second case, a 66-year-old man with diabetes mellitus was treated for pneumonia at another hospital. After the patient’s general condition worsened and he required mechanical ventilation, he was referred to our hospital. The Legionella urinary antigen test was positive. Neither of the patients had been hospitalized or travelled within the previous month. Both patients used hot water storage tanks heated by solar energy; both also used an electrical device in the bathroom to heat the water when solar energy alone was insufficient. The hot water samples from the residences of both patients were positive for L. pneumophila serogroup 1. Conclusion: These cases show that domestic hot water systems heated by solar energy must be considered a possible source of community-acquired LD.

  8. Fast label-free detection of Legionella spp. in biofilms by applying immunomagnetic beads and Raman spectroscopy.

    Science.gov (United States)

    Kusić, Dragana; Rösch, Petra; Popp, Jürgen

    2016-03-01

    Legionellae colonize biofilms, can form a biofilm by itself and multiply intracellularly within the protozoa commonly found in water distribution systems. Approximately half of the known species are pathogenic and have been connected to severe multisystem Legionnaires' disease. The detection methods for Legionella spp. in water samples are still based on cultivation, which is time consuming due to the slow growth of this bacterium. Here, we developed a cultivation-independent, label-free and fast detection method for legionellae in a biofilm matrix based on the Raman spectroscopic analysis of isolated single cells via immunomagnetic separation (IMS). A database comprising the Raman spectra of single bacterial cells captured and separated from the biofilms formed by each species was used to build the identification method based on a support vector machine (SVM) discriminative classifier. The complete method allows the detection of Legionella spp. in 100 min. Cross-reactivity of Legionella spp. specific immunomagnetic beads to the other studied genera was tested, where only small cell amounts of Pseudomonas aeruginosa, Klebsiella pneumoniae and Escherichia coli compared to the initial number of cells were isolated by the immunobeads. Nevertheless, the Raman spectra collected from isolated non-targeted bacteria were well-discriminated from the Raman spectra collected from isolated Legionella cells, whereby the Raman spectra of the independent dataset of Legionella strains were assigned with an accuracy of 98.6%. In addition, Raman spectroscopy was also used to differentiate between isolated Legionella species. Copyright © 2016 Elsevier GmbH. All rights reserved.

  9. Humidifier prevents corrosion and legionella and saves water and energy; Bevochtigingssysteem voorkomt corrosie en legionella en bespaart water en energie

    Energy Technology Data Exchange (ETDEWEB)

    Huizinga, H.T. [Heat Transfer Holland, Zuidwolde (Netherlands)

    2009-04-15

    The renewal of the central water humidifier in the laboratory of DSM-Resins (chemical industry) in Zwolle, Netherlands, leads to a better air conditioning system and prevents corrosion and legionella. At the same time, water and energy consumption are substantially reduced. This renewal fits perfectly within DSM's company policy to decrease the annual energy consumption by 2 %. [Dutch] Het vernieuwen van het centrale waterbevochtigingssysteem in het laboratorium van DSM-Resins te Zwolle verbetert het luchtbehandelingssysteem en voorkomt corrosie en legionella. Tevens vindt er een besparing plaats in water en energiegebruik. Deze vernieuwing past in de beleidsdoelstelling van DSM om iedere jaar 2% minder energie te gebruiken.

  10. Legionellosis and Lung Abscesses: Contribution of Legionella Quantitative Real-Time PCR to an Adapted Followup

    Directory of Open Access Journals (Sweden)

    G. Descours

    2013-01-01

    Full Text Available We report a case of severe Legionnaires' disease (LD complicated by a lung abscess in an immunocompetent patient who required ECMO therapy and thoracic surgery. The results of repeated Legionella quantitative real-time PCR performed on both sera and respiratory samples correlated with the LD severity and the poor clinical outcome. Moreover, the PCR allowed for the detection of Legionella DNA in the lung abscess specimen, which was negative when cultured for Legionella. This case report provides a logical basis for further investigations to examine whether the Legionella quantitative PCR could improve the assessment of LD severity and constitute a prognostic marker.

  11. The role of biofilms and protozoa in Legionella pathogenesis: implications for drinking water

    Science.gov (United States)

    Current models to study Legionella pathogenesis include the use of primary macrophages and monocyte cell lines, various free-living protozoan species and murine models of pneumonia. However, there are very few studies of Legionella spp. pathogenesis aimed at associating the role ...

  12. Legionella Risk Management and Control in Potable Water Systems: Argument for the Abolishment of Routine Testing.

    Science.gov (United States)

    Whiley, Harriet

    2016-12-24

    Legionella is an opportunistic pathogen of public health significance. One of the main sources of Legionella is potable water systems. As a consequence of aging populations there is an increasing demographic considered at high risk for Legionellosis and, as such, a review of the guidelines is required. Worldwide, Legionella has been detected from many potable water sources, suggesting it is ubiquitous in this environment. Previous studies have identified the limitations of the current standard method for Legionella detection and the high possibility of it returning both false negative and false positive results. There is also huge variability in Legionella test results for the same water sample when conducted at different laboratories. However, many guidelines still recommend the testing of water systems. This commentary argues for the removal of routine Legionella monitoring from all water distribution guidelines. This procedure is financially consuming and false negatives may result in managers being over-confident with a system or a control mechanism. Instead, the presence of the pathogen should be assumed and focus spent on managing appropriate control measures and protecting high-risk population groups.

  13. Influence of climate and geography on the occurrence of Legionella and amoebae in composting facilities.

    Science.gov (United States)

    Conza, Lisa; Casati Pagani, Simona; Gaia, Valeria

    2014-11-24

    The incidence of Legionnaires' disease (LD) in southern Switzerland is three times higher than in northern Switzerland. Climatic and geographic factors may be potential causes for this difference.We studied the prevalence of Legionella and free-living amoebae (FLA) in compost and bioaerosol in two Swiss regions to understand the role of climate and geography in the transmission of LD. We also tried to investigate whether or not compost storage duration would influence the composition of Legionella and FLA communities. A larger proportion of compost heaps in facilities from southern Switzerland harbor more diverse Legionella compared to the north (P=0.0146). FLA were isolated from composts in northern facilities at slightly higher rates (88.2% vs. 69.2%) and at lower rates from bioaerosols (6.3% vs. 13%) than in southern Switzerland. The diversity of FLA was higher in northern than in southern Switzerland (80% vs. 65%). A general decrease in the presence and variety of species was observed with decreasing compost storage time length. A discriminant model showed that values of vapour pressure, relative humidity and temperature distinguish the two regions, which were also characterised by different contamination rates by FLA and Legionella. The duration of outdoor storage may favour contamination of the compost by Legionella, and may increase the number and isolation of Legionella naturally occurring in compost. The climate in the south seems to favour higher Legionella contamination of compost heaps: this could explain the higher incidence of LD in southern Switzerland.

  14. Two nursing home outbreaks of respiratory infection with Legionella sainthelensi.

    Science.gov (United States)

    Loeb, M; Simor, A E; Mandell, L; Krueger, P; McArthur, M; James, M; Walter, S; Richardson, E; Lingley, M; Stout, J; Stronach, D; McGeer, A

    1999-05-01

    To describe outbreaks of infection caused by Legionella sainthelensi occurring in older residents of two nursing homes and to determine risk factors for the development of infection. Descriptive epidemiology and a case-control study. Two nursing homes (140 beds and 254 beds in nursing homes A and B, respectively) located in southern Ontario, Canada, experiencing outbreaks of respiratory tract infection in July and August 1994. Case-residents of the two nursing homes who met clinical and laboratory criteria for Legionella infection. Control-residents were defined as those who were in the homes during the outbreaks and were asymptomatic. Active surveillance was conducted in both nursing homes to identify symptomatic residents. Residents with fever or respiratory tract symptoms had nasopharyngeal swabs taken for viral antigen detection and culture, urine for Legionella antigen detection, and acute and convalescent serology for viruses, Mycoplasma pneumoniae, Chlamydia pneumoniae, and Legionella. Chest X-rays were performed, and an attempt was made to obtain blood and sputum cultures. Water samples from shower heads, faucets, and air conditioning units were collected for Legionella culture and polymerase chain reaction (PCR) assay. A case-control study was done to assess possible risk factors for legionellosis. Twenty-nine cases -- 17 in nursing home A; 12 in nursing home B - were identified. Four (14%) case-residents had documented pneumonia and four case-residents died. Univariate analysis revealed that a history of stroke (odds ratio (OR) 2.3 (95% CI, 1.0-5.3)), eating pureed food (OR 4.6 (95% CI, 1.6-12.7)), and having fluids administered with medication (OR 2.5 (95% CI, 1.0-5.9)) were significant risk factors. Cases were less likely to wear dentures (OR .4 (95% CI, .2-.9)) or to eat solid food (OR .3, (95% CI, .1-.6)). Only eating pureed food remained significant in a multivariable analysis (OR 4.6 (95% CI, 1.6-13.0, P = .01)). This report describes outbreaks of

  15. Environmental Legionella spp. collected in urban test sites of South East Queensland, Australia, are virulent to human macrophages in vitro.

    Science.gov (United States)

    Lawrence, Amba; Eglezos, Sofroni; Huston, Wilhelmina

    2016-01-01

    Legionellae are frequent contaminants of potable water supplies, resulting in sporadic infections and occasional outbreaks. Isolates of Legionella were collected from urban test sites within South East Queensland and evaluated for their virulence potential in vitro. Two strains (from the species Legionella londiniensis and Legionella quinlivanii) were demonstrated to have the ability to infect human macrophages, while a strain from the species Legionella anisa did not maintain an infection over the same time course. This suggests that the spectrum of urban environmentally associated Legionella with potential to cause human disease might be greater than currently considered. Copyright © 2015 Institut Pasteur. Published by Elsevier Masson SAS. All rights reserved.

  16. Prevention of legionella in dwellings and buildings; Legionellapreventie in woningen en gebouwen

    Energy Technology Data Exchange (ETDEWEB)

    Van Mil, R.; Van der Kooij, D.; Kolner, W.P.P.; Wessels, R.; Offinga, M.; Scheffer, W.; Van Wolferen, H.; Doldersum, R.; Van der Lugt, W.; Bertrand, F.; Nijlant, E.

    2011-04-15

    In 10 articles and 1 interview attention is paid to several aspects of Legionella in water heaters, mains, and sanitary installations in dwellings and other buildings. [Dutch] In 10 artikelen en 1 interview wordt aandacht besteed aan verschillende aspecten met betrekking tot legionella in sanitaire installaties, waterverwarmingsinstallaties, en waterleidingen in woningen en andere gebouwen.

  17. [Legionella spp. contamination in indoor air: preliminary results of an Italian multicenter study].

    Science.gov (United States)

    Montagna, Maria Teresa; De Giglio, Osvalda; Napoli, Christian; Cannova, Lucia; Cristina, Maria Luisa; Deriu, Maria Grazia; Delia, Santi Antonino; Giuliano, Ada; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Mura, Ida; Pennino, Francesca; Rossini, Angelo; Tardivo, Stefano; Torre, Ida; Torregrossa, Maria Valeria; Villafrate, Maria Rosaria; Albertini, Roberto; Pasquarella, Cesira

    2014-01-01

    To propose a standardized protocol for the evaluation of Legionella contamination in air. A bathroom having a Legionella contamination in water >1,000 cfu/l was selected in 10 different healthcare facilities. Air contamination was assessed by active (Surface Air System, SAS) and passive (Index of Microbial Air, IMA) sampling for 8 hours, about 1 m away from the floor and 50 cm from the tap water. Two hundred liters of air were sampled by SAS every 12 min, after flushing water for 2 min. The IMA value was calculated as the mean value of colony forming units/16 plates exposed during sampling (2 plates/hour). Water contamination was evaluated at T0, after 4 and 8 hours, according to the standard methods. Air contamination by Legionella was found in three healthcare facilities (one with active and two with passive sampling), showing a concomitant tap water contamination (median=40,000; range 1,100-43,000 cfu/l). The remaining seven hospitals isolated Legionella spp. exclusively from water samples (median=8,000; range 1,200-70,000 cfu/l). Our data suggest that environmental Legionella contamination cannot be assessed only through the air sampling, even in the presence of an important water contamination.

  18. Legionellosis Outbreak Associated With a Hotel Fountain

    Science.gov (United States)

    Smith, Shamika S.; Ritger, Kathy; Samala, Usha; Black, Stephanie R.; Okodua, Margaret; Miller, Loretta; Kozak-Muiznieks, Natalia A.; Hicks, Lauri A.; Steinheimer, Craig; Ewaidah, Saadeh; Presser, Lance; Siston, Alicia M.

    2015-01-01

    Background. In August 2012, the Chicago Department of Public Health (CDPH) was notified of acute respiratory illness, including 1 fatality, among a group of meeting attendees who stayed at a Chicago hotel during July 30–August 3, 2012. Suspecting Legionnaires' disease (LD), CDPH advised the hotel to close their swimming pool, spa, and decorative lobby fountain and began an investigation. Methods. Case finding included notification of individuals potentially exposed during July 16–August 15, 2012. Individuals were interviewed using a standardized questionnaire. An environmental assessment was performed. Results. One hundred fourteen cases were identified: 11 confirmed LD, 29 suspect LD, and 74 Pontiac fever cases. Illness onsets occurred July 21–August 22, 2012. Median age was 48 years (range, 22–82 years), 64% were male, 59% sought medical care (15 hospitalizations), and 3 died. Relative risks for hotel exposures revealed that persons who spent time near the decorative fountain or bar, both located in the lobby were respectively 2.13 (95%, 1.64–2.77) and 1.25 (95% CI, 1.09–1.44) times more likely to become ill than those who did not. Legionella pneumophila serogroup 1 was isolated from samples collected from the fountain, spa, and women's locker room fixtures. Legionella pneumophila serogroup 1 environmental isolates and a clinical isolate had matching sequence-based types. Hotel maintenance records lacked a record of regular cleaning and disinfection of the fountain. Conclusions. Environmental testing identified Legionella in the hotel's potable water system. Epidemiologic and laboratory data indicated the decorative fountain as the source. Poor fountain maintenance likely created favorable conditions for Legionella overgrowth. PMID:26716104

  19. Legionellosis Outbreak Associated With a Hotel Fountain.

    Science.gov (United States)

    Smith, Shamika S; Ritger, Kathy; Samala, Usha; Black, Stephanie R; Okodua, Margaret; Miller, Loretta; Kozak-Muiznieks, Natalia A; Hicks, Lauri A; Steinheimer, Craig; Ewaidah, Saadeh; Presser, Lance; Siston, Alicia M

    2015-12-01

    Background.  In August 2012, the Chicago Department of Public Health (CDPH) was notified of acute respiratory illness, including 1 fatality, among a group of meeting attendees who stayed at a Chicago hotel during July 30-August 3, 2012. Suspecting Legionnaires' disease (LD), CDPH advised the hotel to close their swimming pool, spa, and decorative lobby fountain and began an investigation. Methods.  Case finding included notification of individuals potentially exposed during July 16-August 15, 2012. Individuals were interviewed using a standardized questionnaire. An environmental assessment was performed. Results.  One hundred fourteen cases were identified: 11 confirmed LD, 29 suspect LD, and 74 Pontiac fever cases. Illness onsets occurred July 21-August 22, 2012. Median age was 48 years (range, 22-82 years), 64% were male, 59% sought medical care (15 hospitalizations), and 3 died. Relative risks for hotel exposures revealed that persons who spent time near the decorative fountain or bar, both located in the lobby were respectively 2.13 (95%, 1.64-2.77) and 1.25 (95% CI, 1.09-1.44) times more likely to become ill than those who did not. Legionella pneumophila serogroup 1 was isolated from samples collected from the fountain, spa, and women's locker room fixtures. Legionella pneumophila serogroup 1 environmental isolates and a clinical isolate had matching sequence-based types. Hotel maintenance records lacked a record of regular cleaning and disinfection of the fountain. Conclusions.  Environmental testing identified Legionella in the hotel's potable water system. Epidemiologic and laboratory data indicated the decorative fountain as the source. Poor fountain maintenance likely created favorable conditions for Legionella overgrowth.

  20. A rapid detection method using flow cytometry to monitor the risk of Legionella in bath water.

    Science.gov (United States)

    Taguri, Toshitsugu; Oda, Yasunori; Sugiyama, Kanji; Nishikawa, Toru; Endo, Takuro; Izumiyama, Shinji; Yamazaki, Masayuki; Kura, Fumiaki

    2011-07-01

    Legionella species are the causative agents of human legionellosis, and bathing facilities have been identified as the sources of infection in several outbreaks in Japan. Researchers in Japan have recently reported evidence of significant associations between bacterial counts and the occurrence of Legionella in bathing facilities and in a hot tub model. A convenient and quantitative bacterial enumeration method is therefore required as an indicator of Legionella contamination or disinfection to replace existing methods such as time-consuming Legionella culture and expensive Legionella-DNA amplification. In this study, we developed a rapid detection method (RDM) to monitor the risk of Legionella using an automated microbial analyzing device based on flow cytometry techniques to measure the total number of bacteria in water samples within two minutes, by detecting typical patterns of scattered light and fluorescence. We first compared the results of our RDM with plate counting results for five filtered hot spring water samples spiked with three species of bacteria, including Legionella. Inactivation of these samples by chlorine was also assessed by the RDM, a live/dead bacterial fluorescence assay and plate counting. Using the RDM, the lower limit of quantitative bacterial counts in the spiked samples was determined as 3.0×10(3)(3.48log)counts mL(-1). We then used a laboratory model of a hot tub and found that the RDM could monitor the growth curve of naturally occurring heterotrophic bacteria with 1 and 2 days' delayed growth of amoeba and Legionella, respectively, and could also determine the killing curve of these bacteria by chlorination. Finally, samples with ≥3.48 or bacterial counts mL(-1) were tested using the RDM from 149 different hot tubs, and were found to be significantly associated with the positive or negative detection of Legionella with 95% sensitivity and 84% specificity. These findings indicated that the RDM can be used for Legionella control at

  1. [Pulmonary Legionella infection with CNS manifestations].

    Science.gov (United States)

    Pedersen, S W; Kollerup, I

    1998-01-12

    A 39 year-old woman with Legionella pneumonia and severe neurological signs is presented. The patient displayed severe gait disturbance, ataxia and anartria. No substantial remission in symptoms was found at a six month follow up. The case and the relevant literature are reviewed.

  2. Legionella thermalis sp. nov., isolated from hot spring water in Tokyo, Japan.

    Science.gov (United States)

    Ishizaki, Naoto; Sogawa, Kazuyuki; Inoue, Hiroaki; Agata, Kunio; Edagawa, Akiko; Miyamoto, Hiroshi; Fukuyama, Masafumi; Furuhata, Katsunori

    2016-03-01

    Strain L-47(T) of a novel bacterial species belonging to the genus Legionella was isolated from a sample of hot spring water from Tokyo, Japan. The 16S rRNA gene sequences (1477 bp) of this strain (accession number AB899895) had less than 95.0% identity with other Legionella species. The dominant fatty acids of strain L-47(T) were a15:0 (29.6%) and the major ubiquinone was Q-12 (71.1%). It had a guanine-plus-cytosine content of 41.5 mol%. The taxonomic description of Legionella thermalis sp. nov. is proposed to be type strain L-47(T) (JCM 30970(T)  = KCTC 42799(T)). © 2016 The Societies and John Wiley & Sons Australia, Ltd.

  3. Tunge- og stemmebåndsparese efter endotrakeal intubation for Legionella-pneumoni

    DEFF Research Database (Denmark)

    Sønnichsen, Rikke; Lauritsen, Anne Oberg

    2013-01-01

    Extracranial involvement of the hypoglossal nerve and recurrent laryngeal branch of the vagal nerve can be a complication of anaesthetic airway management (Tapia's syndrome) or focal involvement due to Legionella infection. We present a patient with bilateral hypoglossal and unilateral recurrent...... laryngeal nerves palsy after a complicated intubation and a Legionella infection. Clarithromycin therapy was started. Within months, tongue mobility and swallowing gradually improved. Two months after discharge persisting unilateral recurrent nerve palsy was observed....

  4. Criterios microbiológicos y de muestreo establecidos en la legislación vigente para el control de Legionella Microbiological and sampling criteria established in the present Spanish legislation for the control of Legionella

    Directory of Open Access Journals (Sweden)

    Isabel Inza Rojas

    2006-12-01

    Full Text Available Se ha investigado retrospectivamente la relación existente entre las bacterias aerobias totales (BAT y la presencia de Legionella en un total de 576 muestras de agua procedentes de torres de refrigeración industriales. Los resultados revelan un menor porcentaje de muestras positivas para Legionella (19,8% por encima del nivel de 104 UFC/ml BAT establecido como límite de acción, que por debajo de este (80,2%, lo que indica que este limite no cumple su función en las instalaciones investigadas. Niveles de BAT superiores 100 y 1000 UFC/ml parecen ser más útiles para predecir la presencia de Legionella. Hemos observado una concentración de BAT significativamente más elevada en las muestras positivas para Legionella que en las negativas. Esto indica que las BAT son una buena herramienta para la validación de la eficacia del Plan de Autocontol (PA establecido en estas instalaciones. Estos resultados apoyan la importancia de seguir manteniendo el control de las BAT (a 36 ± 1 oC como un indicador de riego de presencia de Legionella y evidencian la necesidad de introducir un límite de acción más bajo para las BAT. Por otra parte se discuten algunos aspectos vinculados a la toma de muestras y a su transporte, y algunos tópicos vinculados al periodo de incubación de la enfermedad y a los métodos de tipado epidemiológico.We have retrospectively investigated the relationship between the presence of total aerobic bacteria (TAB and the presence of Legionella sp. in 576 water samples from industrial cooling towers. A lower percentage of positive samples for Legionella sp. (19.8% was encountered when the concentration of TAB was above 104 CFU/ml than below this concentration (80.2%. The concentration of 104 CFU/ml TAB is established in Spanish legislation as the action limit, above which a higher risk of Legionella positive samples is expected. Despite that, our results indicate that levels of TAB above 100 or 1000 CFU/ml seem more useful for

  5. Legionella confirmation in cooling tower water. Comparison of culture, real-time PCR and next generation sequencing.

    Science.gov (United States)

    Farhat, Maha; Shaheed, Raja A; Al-Ali, Haider H; Al-Ghamdi, Abdullah S; Al-Hamaqi, Ghadeer M; Maan, Hawraa S; Al-Mahfoodh, Zainab A; Al-Seba, Hussain Z

    2018-02-01

    To investigate the presence of Legionella spp in cooling tower water. Legionella proliferation in cooling tower water has serious public health implications as it can be transmitted to humans via aerosols and cause Legionnaires' disease. Samples of cooling tower water were collected from King Fahd Hospital of the University (KFHU) (Imam Abdulrahman Bin Faisal University, 2015/2016). The water samples were analyzed by a standard Legionella culture method, real-time polymerase chain reaction (RT-PCR), and 16S rRNA next-generation sequencing. In addition, the bacterial community composition was evaluated. All samples were negative by conventional Legionella culture. In contrast, all water samples yielded positive results by real-time PCR (105 to 106 GU/L). The results of 16S rRNA next generation sequencing showed high similarity and reproducibility among the water samples. The majority of sequences were Alpha-, Beta-, and Gamma-proteobacteria, and Legionella was the predominant genus. The hydrogen-oxidizing gram-negative bacterium Hydrogenophaga was present at high abundance, indicating high metabolic activity. Sphingopyxis, which is known for its resistance to antimicrobials and as a pioneer in biofilm formation, was also detected. Our findings indicate that monitoring of Legionella in cooling tower water would be enhanced by use of both conventional culturing and molecular methods.

  6. Legionella oakridgensis: laboratory diagnosis of a human infection.

    OpenAIRE

    Tang, P W; Toma, S; MacMillan, L G

    1985-01-01

    We report the laboratory diagnosis of a case of pneumonia caused by Legionella oakridgensis. L. oakridgensis, originally isolated from industrial cooling towers, has not previously been associated with human disease.

  7. Legionellae in water heating systems. Legionellen in Warmwasserbereitungsanlagen

    Energy Technology Data Exchange (ETDEWEB)

    1991-10-01

    A Public Health Office inquiry submitted to the Building Surveyor's Office about prophylactic measures taken to protect the health of bathers at the Vonderort saltwater pools was followed by a detailed inquiry among AMEV members. It was found that most of the persons interviewed did not have sufficient experience in using water heating methods which completely ban legionellae. However, several administrative authorities considered a 60deg C thermal tap water disinfection a necessary protective measure. A circular regulation was subsequently issued by the Northrhine-Westphalian Ministry for Building Construction and Housing to improve legionella protection. Details are also given about the protective measures and maintenance schemes issued by the Public Health Office for drinking water and space HVAC systems. (BWI).

  8. The E. coli immunosorbent as used in serodiagnosis of Legionella infections studied by crossed immunoelectrophoresis

    DEFF Research Database (Denmark)

    Bangsborg, Jette Marie; Friis-Møller, A; Rechnitzer, C

    1988-01-01

    In this study we investigated an immunosorbent, E. coli blocking fluid (BF), proposed for use in the Legionella Indirect Fluorescent Antibody Test (IFA). With crossed immunoelectrophoresis (CIE) of clinically relevant Legionella species, only one heat-stable antigen (no. 1) cross...

  9. Survival of Legionella in earthquake-induced soil disturbance (liquefaction) in residential areas, Christchurch, New Zealand: implications for disease.

    Science.gov (United States)

    Graham, Frances F; Harte, David Jg

    2017-05-12

    To investigate a possible link between liquefaction dust exposure and the noticeable increase in legionellosis cases in response to major earthquakes in 2010 and 2011 that resulted in widespread soil disturbance (liquefaction) in parts of Christchurch, New Zealand. We culture tested liquefaction-affected soil for Legionella spp. in the six months following the first earthquake in 2010. Thirty silt samples were collected randomly from locations within Christchurch's metropolitan area that were affected by liquefaction. The samples were tested to determine the presence of Legionella using qualitative and quantitative methods. Liquefaction-affected soil samples from three sites were further subjected to particle size distribution analysis and determination of major oxides. A controlled field study was established using six silt samples and one control (commercial compost), seeded with a wild-type strain of Legionella bozemanae serogroup (sg) 1 and persistence monitored over a 60-day period by culturing for the presence of Legionella. Dry matter determinations were undertaken so that total Legionella could be calculated on a dry weight basis. Legionella bacteria were undetectable after day one in the silt samples. However, L. bozemanae sg1 was detected in the control sample for the entire study period. This study showed that the liquefaction-affected soil could not contribute directly to the observed increase in legionellosis cases after the earthquakes due to its inability to support growth and survival of the Legionella bacteria.

  10. Systemic Character of Legionnaires’ Disease – A Murine Model

    Directory of Open Access Journals (Sweden)

    Marina Šantić

    2003-01-01

    Full Text Available In contrast to lung infection caused by Legionella pneumophila, little is known about the pathogenesis of this disease in other organs. In this study, we analyzed the number of colony forming units (CFU of legionellae not only in lungs but also in EDTA plasma, liver, spleen and kidneys. The number of CFU was determined 2, 24, 48, 72 and 168 h after intratracheal inoculation. Results showed that the inflammatory response was mostly pronounced in lungs. Legionellae, however, were also found in EDTA plasma and all the other investigated organs. The duration of infection was most protracted in lungs, with persistence for at least 168 h. In the remaining organs, legionellae were found for a maximum of 72 h after inoculation. Besides the culture methods used for detection of CFU we also used LightCycler (LC PCR to confirm the presence of bacteria in the blood of intratracheally infected mice. By this method the bacterial DNA could be detected during the first two days of post infection.

  11. Legionella pneumonia presenting with bilateral flank pain, hyponatraemia and acute renal failure

    OpenAIRE

    Birkin, Celia; Biyani, Chandra Shekhar; Browning, Anthony J.

    2011-01-01

    Legionnaires’ disease (LD) is an often overlooked but a possible cause of sporadic community acquired pneumonia. High fever, cough and gastrointestinal symptoms are non-specific symptoms. Hyponatremia is more common in LD than pneumonia linked with other causes. A definitive diagnosis is usually confirmed by culture, urinary antigen testing for Legionella species. Macolide or quinolone antibiotic is the treatment of choice. We describe a case of Legionella pneumonia presenting with high fever...

  12. NEUMONÍA POR AGENTES ATÍPICOS EN NIÑOS

    OpenAIRE

    Inostroza, Erika; Pinto, Ricardo

    2017-01-01

    La neumonía adquirida en la comunidad es una enfermedad frecuente en todas las edades. Los agentes “atípicos” Mycoplasma pneumoniae, Chlamydophila pneumoniae y Legionella pneumophila constituyen un grupo de bacterias con características microbiológicas y clínicas particulares que se deben conocer para lograr un diagnóstico oportuno y un tratamiento antibiótico adecuado.

  13. Chlamydia trachomatis Mip-like protein

    DEFF Research Database (Denmark)

    Lundemose, AG; Rousch, DA; Birkelund, Svend

    1992-01-01

    A 27 kDa Chlamydia trachomatis Mip-like protein with homology of a 175-amino-acid C-terminal fragment to the surface-exposed Legionella pneumophila mip-gene product has previously been described. In this paper the entire chlamydia Mip-like sequence of C. trachomatis serovar L2 (lymphogranuloma...... venereum (LGV) biovar) is presented. The sequence shows high similarity to the legionella Mip protein and its C-terminal region, like that of the legionella Mip, has high amino acid similarity to eukaryotic and prokaryotic FK506-binding proteins. The chlamydial mip-like gene was detected by polymerase...... chain reaction (PCR) in other C. trachomatis serovars and by sequencing of the mip-like genes of serovars B and E (trachoma biovar) was shown to be highly conserved within the two major biovars of C. trachomatis. Monoclonal and polyclonal antibodies raised against the recombinant Mip-like protein failed...

  14. Detection of Legionella species in environmental water by the quantitative PCR method in combination with ethidium monoazide treatment.

    Science.gov (United States)

    Inoue, Hiroaki; Takama, Tomoko; Yoshizaki, Miwa; Agata, Kunio

    2015-01-01

    We detected Legionella species in 111 bath water samples and 95 cooling tower water samples by using a combination of conventional plate culture, quantitative polymerase chain reaction (qPCR) and qPCR combined with ethidium monoazide treatment (EMA-qPCR) methods. In the case of bath water samples, Legionella spp. were detected in 30 samples by plate culture, in 85 samples by qPCR, and in 49 samples by EMA-qPCR. Of 81 samples determined to be Legionella-negative by plate culture, 56 and 23 samples were positive by qPCR and EMA-qPCR, respectively. Therefore, EMA treatment decreased the number of Legionella-positive bath water samples detected by qPCR. In contrast, EMA treatment had no effect on cooling tower water samples. We therefore expect that EMA-qPCR is a useful method for the rapid detection of viable Legionella spp. from bath water samples.

  15. Filamoeba sp. Isolated from Hot-water Piping System, a Host of Legionella Closely Related to Legionella micdadei

    Czech Academy of Sciences Publication Activity Database

    Dyková, Iva; Hrubá, L.; Kostka, Martin; Pecková, Hana

    2009-01-01

    Roč. 48, č. 4 (2009), s. 321-327 ISSN 0065-1583 R&D Projects: GA ČR GA524/09/0137; GA MŠk LC522 Institutional research plan: CEZ:AV0Z60220518 Keywords : Filamoeba sp. * intracellular * Legionella sp. Subject RIV: GJ - Animal Vermins ; Diseases, Veterinary Medicine Impact factor: 0.775, year: 2009

  16. Molecular characterization of viable Legionella spp. in cooling tower water samples by combined use of ethidium monoazide and PCR.

    Science.gov (United States)

    Inoue, Hiroaki; Fujimura, Reiko; Agata, Kunio; Ohta, Hiroyuki

    2015-01-01

    Viable Legionella spp. in environmental water samples were characterized phylogenetically by a clone library analysis combining the use of ethidium monoazide and quantitative PCR. To examine the diversity of Legionella spp., six cooling tower water samples and three bath water samples were collected and analyzed. A total of 617 clones were analyzed for their 16S rRNA gene sequences and classified into 99 operational taxonomic units (OTUs). The majority of OTUs were not clustered with currently described Legionella spp., suggesting the wide diversity of not-yet-cultured Legionella groups harbored in cooling tower water environments.

  17. The presence and growth of Legionella species in thermostatic shower mixer taps: an exploratory field study

    NARCIS (Netherlands)

    Joost van Hoof; P.W.J.J. van der Wielen; E. van der Blom; O.W.W. Nuijten; L. Hornstra

    2014-01-01

    Legislation in the Netherlands requires routine analysis of drinking water samples for cultivable Legionella species from high-priority installations. A field study was conducted to investigate the presence of Legionella species in thermostatic shower mixer taps. Water samples and the interior of

  18. Efficacy of SCH27899 in an Animal Model of Legionnaires' Disease Using Immunocompromised A/J Mice

    Science.gov (United States)

    Brieland, Joan K.; Loebenberg, David; Menzel, Fred; Hare, Roberta S.

    2000-01-01

    The efficacy of SCH27899, a new everninomicin antibiotic, against replicative Legionella pneumophila lung infections in an immunocompromised host was evaluated using a murine model of Legionnaires' disease. A/J mice were immunocompromised with cortisone acetate and inoculated intratracheally with L. pneumophila serogroup 1 (105 CFU per mouse). At 24 h postinoculation, mice were administered either SCH27899 (6 to 60 mg/kg [MPK] intravenously) or a placebo once daily for 5 days, and mortality and intrapulmonary growth of L. pneumophila were assessed. In the absence of SCH27899, there was 100% mortality in L. pneumophila-infected mice, with exponential intrapulmonary growth of the bacteria. In contrast, administration of SCH27899 at a dose of ≥30 MPK resulted in ≥90% survival of infected mice, which was associated with inhibition of intrapulmonary growth of L. pneumophila. In subsequent studies, the efficacy of SCH27899 was compared to ofloxacin (OFX) and azithromycin (AZI). Administration of SCH27899, OFX, or AZI at a dose of ≥30 MPK once daily for 5 days resulted in ≥85% survival of infected mice and inhibition of intrapulmonary growth of the bacteria. However, L. pneumophila CFU were recovered in lung homogenates following cessation of therapy with all three antibiotics. These studies demonstrate that SCH27899 effectively prevents fatal replicative L. pneumophila lung infection in immunocompromised A/J mice by inhibition of intrapulmonary growth of the bacteria. However, in this murine model of pulmonary legionellosis, SCH27899, like OFX and AZI, was bacteriostatic. PMID:10770771

  19. Genetic relatedness of Legionella longbeachae isolates from human and environmental sources in Australia

    International Nuclear Information System (INIS)

    Lanser, J.A.; Doyle, R.; Sangster, N.; Steele, T.W.; Adams, M.

    1990-01-01

    The genetic relatedness of Legionella longbeachae isolated in Australia since 1987 was investigated by restriction fragment length polymorphism (RFLP) analysis and allozyme electrophoresis. Three radiolabeled probes were used in Southern hybridizations for the RFLP studies. They were Escherichia coli 16S and 23S rRNA and cloned fragments of L. longbeachae selected empirically from genomal banks in lambda and a cosmid. The legionellae included in the study comprised 11 Legionella longbeachae serogroup 1 organisms isolated form humans, 28 L. longbeachae serogroup 1 isolates from environmental sources, 3 L. longbeachae serogroup 2 environmental isolates. These were compared with the American Type Culture Collection reference strains of both serogroups and some other related Legionella species. Results of allozyme and RFLP analysis showed that all the isolates from humans and all but three of the environmental L. longbeachae serogroup 1 isolates were closely related. They were also closely related to L. longbeachae serogroup 1 ATCC 33462. There was wider variation among the three L. longbeachae serogroup 2 environmental isolates. One of these was closely related to L. longbeachae serogroup 2 ATCC 33484. RFLP studies with the rRNA probe provided the most discrimination among isolates but did not distinguish between the two serogroups

  20. Hospital-acquired Legionella infections: an update on the procedures for controlling environmental contamination.

    Science.gov (United States)

    Borella, P; Bargellini, A; Marchegiano, P; Vecchi, E; Marchesi, I

    2016-01-01

    The waterborne healthcare-associated infections are mainly sustained by Legionella and Pseudomonas spp. Various water factors and plumbing characteristics, and the interaction with other water microorganisms are considered to be predictive of Legionella contamination. It is therefore mandatory to organize plans of surveillance, prevention and control in order to avoid disease appearance in immunosuppressed patients, with higher risk of death. Guidelines for the prevention of Legionnaires' disease have been published, benefiting those who face this problem, but definitive standardized solutions do not exist yet. Here we describe fifteen years of activity, during which our study group gathered interesting data on the control of Legionella contamination. Water disinfection is not generally sufficient to control the risk of infection, but a complex water safety plan should be developed, including system maintenance, training of staff and implementation of a clinical surveillance system aimed at early detection of cases. Concerning the control measures, we evaluated the effectiveness of different treatments suggested to reduce Legionella spp contamination, comparing our results with the current literature data. The performance ranking was highest for the filter, followed by boilers at high temperature, monochloramine and, at a lower level, chlorine dioxide; the effectiveness of hyperchlorination was limited, and thermal shock was even more ineffective.