WorldWideScience

Sample records for left ventricular volumes

  1. Studies of left ventricular volume estimation from single photon emission computed tomography

    International Nuclear Information System (INIS)

    Hiraki, Yoshio; Shimizu, Mitsuharu; Joja, Ikuo; Aono, Kaname; Yanagi, Hidekiyo; Indo, Haruaki; Seno, Yoshimasa; Teramoto, Shigeru; Nagaya, Isao.

    1988-01-01

    We studied the comparative accuracy of 99m Tc cardiac blood pool Single Photon Emission Computed Tomography (SPECT) for the measurement of left ventricular volume in 20 patients undergoing SPECT and single plane contrast left ventriculography (LVG). Left ventricular volume was calculated based on the total number of voxels in left ventricle. End-diastolic left ventricular volume (EDV) and end-systolic left ventricular volume (ESV) calculated from SPECT were compared with those from LVG. SPECT volume values showed a high degree of correlation with those by LVG (r = 0.923 for EDV, r = 0.903 for ESV). We appreciated the usefulness and accuracy of SPECT in measuring left ventricular volume because of its three-dimensional information. (author)

  2. Significance of left ventricular volume measurement after heart transplantation using radionuclide techniques

    International Nuclear Information System (INIS)

    Novitzky, D.; Cooper, D.; Boniaszczuk, J.

    1985-01-01

    Multigated equilibrium blood pool scanning using Technetium 99m labeled red blood cells was used to measure left ventricular volumes in three heterotopic and one orthotopic heart transplant recipient(s). Simultaneously, an endomyocardial biopsy was performed and the degree of acute rejection was assessed by a histological scoring system. The scores were correlated to changes in ejection fraction and heart rate. Technetium 99m scanning data were pooled according to the endomyocardial biopsy score: no rejection; mild rejection; moderate rejection, and severe rejection. In each group, the median of the left ventricular volume parameters was calculated and correlated with the endomyocardial biopsy score, using a non-parametric one-way analysis of variance. A decrease in stroke volume correlated best with the endomyocardial biopsy score during acute rejection. A decrease in end-diastolic left ventricular volumes did not correlate as well. Changes in the end-systolic left ventricular volumes were not statistically significant, but using a simple correlation between end-systolic left ventricular volumes and endomyocardial biopsy the correlation reached significance. Changes in left ventricular volumes measured by Technetium 99m scanning may be useful to confirm the presence or absence of acute rejection in patients with heart grafts

  3. Comparison of the accuracy of three angiographic methods for calculating left ventricular volume measurement

    International Nuclear Information System (INIS)

    Hu Lin; Cui Wei; Shi Hanwen; Tian Yingping; Wang Weigang; Feng Yanguang; Huang Xueyan; Liu Zhisheng

    2003-01-01

    Objective: To compare the relative accuracy of three methods measuring left ventricular volume by X-ray ventriculography: single plane area-length method, biplane area-length method, and single-plane Simpson's method. Methods: Left ventricular casts were obtained within 24 hours after death from 12 persons who died from non-cardiac causes. The true left ventricular cast volume was measured by water displacement. The calculated volume of the casts was obtained with 3 angiographic methods, i.e., single-plane area-length method, biplane area-length method, and single-plane Simpson's method. Results: The actual average volume of left ventricular casts was (61.17±26.49) ml. The left ventricular volume was averagely (97.50±35.56) ml with single plane area-length method, (90.51±36.33) ml with biplane area-length method, and (65.00± 23.63) ml with single-plane Simpson's method. The left ventricular volumes calculated with single-plane and biplane area-length method were significantly larger than that the actual volumes (P 0.05). The left ventricular volumes calculated with single-plane and biplane area-length method were significantly larger than those calculated with single-plane Simpson's method (P 0.05). The over-estimation of left ventricular volume by single plane area-length method (36.34±17.98) ml and biplane area-length method (29.34±15.59) ml was more obvious than that calculated by single-plane Simpson's method (3.83±8.48) ml. Linear regression analysis showed that there was close correlations between left ventricular volumes calculated with single plane area-length method, biplane area-length method, Simpson's method and the true volume (all r>0.98). Conclusion: Single-plane Simpson's method is more accurate than single plane area-length method and biplane area-length method for left ventricular volume measurement; however, both the single-plane and biplane area-length methods could be used in clinical practice, especially in those imaging modality

  4. Evaluation of left ventricular volumes measured by magnetic resonance imaging

    DEFF Research Database (Denmark)

    Møgelvang, J; Thomsen, C; Mehlsen, J

    1986-01-01

    Left ventricular end-diastolic and end-systolic volumes were determined in 17 patients with different levels of left ventricular function by magnetic resonance imaging (MRI). A 1.5 Tesla Magnet was used obtaining ECG triggered single and multiple slices. Calculated cardiac outputs were compared...

  5. Left ventricular pressure and volume data acquisition and analysis using LabVIEW.

    Science.gov (United States)

    Cassidy, S C; Teitel, D F

    1997-03-01

    To automate analysis of left ventricular pressure-volume data, we used LabVIEW to create applications that digitize and display data recorded from conductance and manometric catheters. Applications separate data into cardiac cycles, calculate parallel conductance, and calculate indices of left ventricular function, including end-systolic elastance, preload-recruitable stroke work, stroke volume, ejection fraction, stroke work, maximum and minimum derivative of ventricular pressure, heart rate, indices of relaxation, peak filling rate, and ventricular chamber stiffness. Pressure-volume loops can be graphically displayed. These analyses are exported to a text-file. These applications have simplified and automated the process of evaluating ventricular function.

  6. Systolic left ventricular function according to left ventricular concentricity and dilatation in hypertensive patients

    DEFF Research Database (Denmark)

    Bang, Casper; Gerdts, Eva; Aurigemma, Gerard P

    2013-01-01

    Left ventricular hypertrophy [LVH, high left ventricular mass (LVM)] is traditionally classified as concentric or eccentric based on left ventricular relative wall thickness. We evaluated left ventricular systolic function in a new four-group LVH classification based on left ventricular dilatation...... [high left ventricular end-diastolic volume (EDV) index and concentricity (LVM/EDV)] in hypertensive patients....

  7. Effect of Hemodialysis on Left and Right Ventricular Volume and Function

    International Nuclear Information System (INIS)

    Han, Jin Suk; Koh, Chang Soon

    1985-01-01

    With the improvement of hemodialysis, the course of thc discase in patient with endstage renal disease has been clearly improved. Nevertheless, among several shortcomings to our present mode of renal replacement therapy, cardiovascular complications have been the leading cause of morbidity and mortality. Several factors such as anemia, arteriovenous shunting of blood, intermittent extracorporeal circulation and hypertension may be contributing. But little is known about the quantitative cardiac hemodynamic characteristics occurred during hemodialysis. The purpose of this study is to observe the sequential hemodynamic changes before, during and after the hemodialysis and to investigate: reliable parameters in the detection of ventricular dysfunction. In the present study, equilibrium radionuclide cardiac angiography was performed and left and right ventricular volume indices, ejection phase indices of both ventricular, performance were measured in the 16 stable patients with chronic renal failure treated with maintenance hemodialysis sequentially i.e. before, during (carly and late phase) and after the hemodialysis. The results obtained were as follows; 1) The indices of the left ventricular function were not changed during the hemodialysis but increased after the hemodialysis. 2) The indices of the right ventricular function(EF, SVI) were significantly decreased in the early phase (15, 30 minutes after starting extracorporeal circulation) but recovered after the hemodialysis, 3) The ratio of right ventricular to left ventricular ejection fraction was significantly decreased in the early phase and the lung volume indices were significantly increased at the same phase. As a conclusion, hemodialysis improves left ventricular function maybe du to increased contractility, and effects on the right ventricular function maybe due to the increased lung volume in the early phase of hemodialysis.

  8. Effect of Hemodialysis on Left and Right Ventricular Volume and Function

    Energy Technology Data Exchange (ETDEWEB)

    Han, Jin Suk; Koh, Chang Soon [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1985-09-15

    With the improvement of hemodialysis, the course of thc discase in patient with endstage renal disease has been clearly improved. Nevertheless, among several shortcomings to our present mode of renal replacement therapy, cardiovascular complications have been the leading cause of morbidity and mortality. Several factors such as anemia, arteriovenous shunting of blood, intermittent extracorporeal circulation and hypertension may be contributing. But little is known about the quantitative cardiac hemodynamic characteristics occurred during hemodialysis. The purpose of this study is to observe the sequential hemodynamic changes before, during and after the hemodialysis and to investigate: reliable parameters in the detection of ventricular dysfunction. In the present study, equilibrium radionuclide cardiac angiography was performed and left and right ventricular volume indices, ejection phase indices of both ventricular, performance were measured in the 16 stable patients with chronic renal failure treated with maintenance hemodialysis sequentially i.e. before, during (carly and late phase) and after the hemodialysis. The results obtained were as follows; 1) The indices of the left ventricular function were not changed during the hemodialysis but increased after the hemodialysis. 2) The indices of the right ventricular function(EF, SVI) were significantly decreased in the early phase (15, 30 minutes after starting extracorporeal circulation) but recovered after the hemodialysis, 3) The ratio of right ventricular to left ventricular ejection fraction was significantly decreased in the early phase and the lung volume indices were significantly increased at the same phase. As a conclusion, hemodialysis improves left ventricular function maybe du to increased contractility, and effects on the right ventricular function maybe due to the increased lung volume in the early phase of hemodialysis.

  9. Determination of left ventricular volume using gated blood pool tomography comparison with contrast ventriculography

    International Nuclear Information System (INIS)

    Lu Ping; Mo Lijun; Liu Xiujie

    1992-01-01

    48 patients with cardiac disease were studied with gated blood pool tomography to determine left ventricular volume at end diastole, end-systole and ejection fraction. The volumes were calculated from serial short-axis tomograms by multiplying the number of pixels and the known volume of each pixel. Excellent correlation was found between blood pool tomography and contrast ventriculographic volume. At end-diastole, r = 0.91 (P < 0.01); at end-systole, r = 0.95 (P < 0.01); for left ventricular ejection fraction, r 0.90 (P < 0.01). The results suggest that gated blood pool tomography is a promising noninvasive and direct method for measuring left ventricular volume

  10. Right and Left Ventricular Volumes in Atrial Septal Defect Studied by Radiocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Ivancevic, D. [Radioisotope Department, Internal Clinic, Rebro, Zagreb, Yugoslavia (Croatia); Vernejoul, P. de; Kellershohn, C. [CEA, Service Hospitalier Frederic Joliot, Departement de Biologie, Orsay (France)

    1971-02-15

    Radiocardiography with radioiodinated ({sup 131}I) human serum albumin and barium ({sup 137m}Ba) solution injected into the right subclavian vein has been performed in a group of 43 patients with atrial septal defect and left-to-right shunt. Data on the output and ejection index of each ventricle are essential for the estimation of the diastolic and residual volumes of the right and left ventricle. The systemic flow was therefore calculated according to Veall's formula and the pulmonary flow and the shunt How were determined using the method of de Vernejoul and co-workers. The formulas for the calculation of ventricular volumes were modified. The results show that many cases of atrial septal defect have an enlarged right ventricle whereas the left ventricle remains normal or is diminished. These changes correlate well with the amount of the shunt flow. In both ventricles the ventricular volumes show a good correlation with the stroke volumes. For the regulation of the pulmonary blood volume the right ventricle seems to be more important than the left ventricle. The operative closure of atrial septal defect (in 14 patients) has normalized the size of ventricular volumes. (author)

  11. Measurement of absolute left ventricular volume by radionuclide angiography: a technical review

    International Nuclear Information System (INIS)

    Al-Khawaja, I.M.; Lahiri, Avijit; Raftery, E.B.; Medical Research Council, Harrow

    1988-01-01

    Absolute left ventricular volumes have important clinical implications in the evaluation of cardiac performance. Several invasive and noninvasive techniques have been reported, none of which can be considered ideal for this purpose. Contrast angiography, echocardiography and radionuclide ventriculography are open to criticism. Different radioisotopic approaches are described with emphasis on the importance of accurate separation of left ventricular activity, the selection of background activity, and the correction for photon attenuation by body tissues. Improper use of statistics and validation techniques have obscured the value of these techniques. In the absence of a 'gold standard' there should be a 'radioisotopic' left ventricular volume with established independent characteristics, repeatability and reproducibility by which new approaches can be judged. (author)

  12. Radionuclide stroke count ratios for assessment of right and left ventricular volume overload in children

    International Nuclear Information System (INIS)

    Parrish, M.D.; Graham, T.P. Jr.; Born, M.L.; Jones, J.P.; Boucek, R.J. Jr.; Artman, M.; Partain, C.L.

    1983-01-01

    The ratio of left ventricular to right ventricular stroke counts measured by radionuclide angiography has been used in adults to estimate the severity of left-sided valvular regurgitation. The validation of this technique in children for assessment of right and left ventricular volume overload is reported herein. Radionuclide stroke count ratios in 60 children aged 0.5 to 19 years (mean 11) were determined. Based on their diagnoses, the patients were divided into 3 groups: (1) normal--40 patients with no shunts or valvular regurgitation, (2) left ventricular volume overload--13 patients with mitral or aortic regurgitation, or both, and (3) right ventricular volume overload--7 patients, 2 with severe tricuspid regurgitation, 3 with atrial septal defects, and 2 with total anomalous pulmonary venous drainage. The radionuclide stroke count ratio clearly differentiated these groups (p less than 0.05): normal patients had a stroke count ratio of 1.04 +/- 0.17 (mean +/- 1 standard deviation), the left ventricular volume overload group had a stroke count ratio of 2.43 +/- 0.86, and the right ventricular volume overload group had a stroke count ratio of 0.44 +/- 0.17. In 22 of our 60 patients, radionuclide stroke count ratios were compared with cineangiographic stroke volume ratios, resulting in a correlation coefficient of 0.88. It is concluded that radionuclide ventriculography is an excellent tool for qualitative and quantitative assessment of valvular regurgitation in children

  13. Beneficial effects of elevating cardiac preload on left-ventricular diastolic function and volume during heat stress

    DEFF Research Database (Denmark)

    Brothers, R M; Pecini, Redi; Dalsgaard, Morten

    2014-01-01

    via volume loading while heat stressed would 1) increase indices of left ventricular diastolic function, and 2) preserve left ventricular end-diastolic volume (LVEDV) during a subsequent simulated hemorrhagic challenge induced by lower-body negative pressure (LBNP). Indices of left ventricular......Volume loading normalizes tolerance to a simulated hemorrhagic challenge in heat-stressed individuals, relative to when these individuals are thermoneutral. The mechanism(s) by which this occurs is unknown. This project tested two unique hypotheses; that is, the elevation of central blood volume...... diastolic function were evaluated in nine subjects during the following conditions: thermoneutral, heat stress, and heat stress after acute volume loading sufficient to return ventricular filling pressures toward thermoneutral levels. LVEDV was also measured in these subjects during the aforementioned...

  14. Left ventricular volume determination from single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Bunker, S.R.; Hartshorne, M.F.; Schmidt, W.P.; Cawthon, M.A.; Karl, R.D. Jr.; Bauman, J.M.; Howard, W.H. III; Rubal, B.J.

    1985-01-01

    To compare the accuracy of single-photon emission computed tomography (SPECT) with that of contrast cineangiography in measuring left ventricular end-diastolic volume, 25 consecutive patients undergoing catheterizaiton for coronary artery or valvular heart disease were first evaluated scintigraphically. SPECT volume values showed a high degree of correlation with those determined by angiography with a standard error of the estimate of 23 ml. SPECT offers a highly accurate and essentially noninvasive method for measuring chamber volumes that is independent of geometric assumptions about ventricular configuration and chest wall attenuation and does not require blood sample counting

  15. Left ventricular volume determination from single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Bunker, S.R.; Hartshorne, M.F.; Schmidt, W.P.; Cawthon, M.A.; Karl, R.D. Jr.; Bauman, J.M.; Howard, W.H. III; Rubal, B.J.

    1985-02-01

    To compare the accuracy of single-photon emission computed tomography (SPECT) with that of contrast cineangiography in measuring left ventricular end-diastolic volume, 25 consecutive patients undergoing catheterizaiton for coronary artery or valvular heart disease were first evaluated scintigraphically. SPECT volume values showed a high degree of correlation with those determined by angiography with a standard error of the estimate of 23 ml. SPECT offers a highly accurate and essentially noninvasive method for measuring chamber volumes that is independent of geometric assumptions about ventricular configuration and chest wall attenuation and does not require blood sample counting.

  16. Value of radionuclide angiocardiography for determination of left ventricular volume in patients with valvular heart disease

    International Nuclear Information System (INIS)

    Konieczna, S.; Madeja, G.; Gosiewska-Marcinkowska, E.; Szumilak, B.; Brodzki, L.M.; Leszek, P.

    1992-01-01

    The aim of this study was to investigate usability of the Massardo method in calculating the left ventricular volume in patients with valvular defect. The group consisted of 21 patients with mitral defect. Left ventricular volumes obtained by contrast ventriculography were used for reference. The correlation coefficient between these two methods was 0.94, SEE=29 ml, V nucl =0.94 V c.vent +11. The end-systolic and end-diastolic outlines were marked manually. We concluded that the Massardo methods is an effective method of calculating the left ventricular volume also in group of patients with mitral defect. (author). 11 refs, 4 tabs

  17. Diastolic compliance and exercise-induced left ventricular diastolic volume changes in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Choi, W.; Varma, V.; Wasserman, A.; Katz, R.; Reba, R.; Ross, A.

    1983-01-01

    This study consists of 46 consecutive patients who had supine resting and exercise multigated (MUGA) blood pool studies. All patients had angio-graphically important coronary stenosis in at least one major vessel. Thirty-five out of 46 patients with coronary artery disease increased left ventricular end diastolic volume with a supine exercise. The remaining eleven patients dit not dilate the left ventricle. Those patients, who were able to increase their end diastolic volume during exercise, had better compliance of the left ventricle manifested by lower end diastolic pressures, whereas, patients with poor left ventricular compliance were unable to volume expand during supine exercise

  18. Usefulness of acoustic quantification method in left ventricular volume and ejection fraction. Compared with ventriculography and scintigraphy

    International Nuclear Information System (INIS)

    Shibata, Takahiro; Honda, Youichi; Kashiwagi, Hidehiko

    1996-01-01

    Acoustic quantification method (AQ: on-line automated boundary detection system) has proved to have a good correlation with left ventriculography (LVG) and scintigraphy (SG) in patients with normal left ventricular (LV) function. The aim of this study is to determine whether AQ is also useful in patients with abnormal LV function. We examined 54 patients with LV asynergy. End-diastolic volumes with AQ, LVG and SG were 77, 135, 118 ml. A good correlation was found between AQ and LVG and SG (LVG; r=0.81, SG; r=0.68). End-systolic volumes with AQ, LVG and SG were 38, 64 and 57 ml. Left ventricular volumes obtained from AQ had a good correlation with LVG and SG, but were underestimated. LV ejection fraction obtained from AQ had good correlation with those with LVG and SG (LVG; r=0.84. SG; r=0.77). On-line AQ appears to be a useful noninvasive method for evaluation of the left ventricular ejection fraction, but care must be exercised when estimations of left ventricular volumes are made. (author)

  19. Epicardial left ventricular lead placement for cardiac resynchronization therapy: optimal pace site selection with pressure-volume loops.

    Science.gov (United States)

    Dekker, A L A J; Phelps, B; Dijkman, B; van der Nagel, T; van der Veen, F H; Geskes, G G; Maessen, J G

    2004-06-01

    Patients in heart failure with left bundle branch block benefit from cardiac resynchronization therapy. Usually the left ventricular pacing lead is placed by coronary sinus catheterization; however, this procedure is not always successful, and patients may be referred for surgical epicardial lead placement. The objective of this study was to develop a method to guide epicardial lead placement in cardiac resynchronization therapy. Eleven patients in heart failure who were eligible for cardiac resynchronization therapy were referred for surgery because of failed coronary sinus left ventricular lead implantation. Minithoracotomy or thoracoscopy was performed, and a temporary epicardial electrode was used for biventricular pacing at various sites on the left ventricle. Pressure-volume loops with the conductance catheter were used to select the best site for each individual patient. Relative to the baseline situation, biventricular pacing with an optimal left ventricular lead position significantly increased stroke volume (+39%, P =.01), maximal left ventricular pressure derivative (+20%, P =.02), ejection fraction (+30%, P =.007), and stroke work (+66%, P =.006) and reduced end-systolic volume (-6%, P =.04). In contrast, biventricular pacing at a suboptimal site did not significantly change left ventricular function and even worsened it in some cases. To optimize cardiac resynchronization therapy with epicardial leads, mapping to determine the best pace site is a prerequisite. Pressure-volume loops offer real-time guidance for targeting epicardial lead placement during minimal invasive surgery.

  20. The influence of right ventricular apical pacing on left atrial volume in patients with normal left ventricular function

    Directory of Open Access Journals (Sweden)

    AR Moaref1

    2008-03-01

    Full Text Available Background: Right ventricular apical (RVA pacing has been reported to induce several deleterious effects particularly in the presence of structural heart disease but can also involve patients with normal left ventricular (LV function. Left atrial (LA enlargement is one of these effects, but the majority of studies have measured LA dimension rather than volume.Objective: The present prospective study was designed to assess the effect of RVA pacing on LA volume in patients with normal LV function.Patients and Methods: The study comprised 41 consecutive patients with LV ejection fraction ≥ 45% and LV end diastolic dimension ≤ 56 mm who underwent single-or dual- chamber pacemaker implantation in RVA and followed for LA volume measurement and pacemaker analysis at least during the ensuing 4.2 months. Results: In all, 21 patients were excluded from the study due to five spontaneous wide QRS complex (≥120msec, one recent acute coronary syndrome,one significant valvular heart disease, three pacing frequency <90%, eight death or losing follow up in three cases. In remaining 20 patients, LA volume ragned from 21 to 54 mm3 with mean of 37.3±9.7 mm3 prior to pacemaker implantation that increased to 31 to 103 mm3 (54.3±17.0 during follow-up (P<0.001.Conclusion: RVA pacing might lead to an increase in LA volume even in patients with normal LV function.

  1. Radionuclide analysis of right and left ventricular response to exercise in patients with atrial and ventricular septal defects

    International Nuclear Information System (INIS)

    Peter, C.A.; Bowyer, K.; Jones, R.H.

    1983-01-01

    In patients with ventricular or atrial septal defect, the ventricle which is chronically volume overloaded might not appropriately respond to increased demand for an augmentation in output and thereby might limit total cardiac function. In this study we simultaneously measured right and left ventricular response to exercise in 10 normal individuals, 10 patients with ventricular septal defect (VSD), and 10 patients with atrial septal defect (ASD). The normal subjects increased both right and left ventricular ejection fraction, end-diastolic volume, and stroke volume to achieve a higher cardiac output during exercise. Patients with VSD failed to increase right ventricular ejection fraction, but increased right ventricular end-diastolic volume and stroke volume. Left ventricular end-diastolic volume did not increase in these patients but ejection fraction, stroke volume, and forward left ventricular output achieved during exercise were comparable to the response observed in healthy subjects. In the patients with ASD, no rest-to-exercise change occurred in either right ventricular ejection fraction, end-diastolic volume, or stroke volume. In addition, left ventricular end-diastolic volume failed to increase, and despite an increase in ejection fraction, left ventricular stroke volume remained unchanged from rest to exercise. Therefore, cardiac output was augmented only by the heart rate increase in these patients. Right ventricular function appeared to be the major determinant of total cardiac output during exercise in patients with cardiac septal defects and left-to-right shunt

  2. Depressed left ventricular performance. Response to volume infusion in patients with sepsis and septic shock

    International Nuclear Information System (INIS)

    Ognibene, F.P.; Parker, M.M.; Natanson, C.; Shelhamer, J.H.; Parrillo, J.E.

    1988-01-01

    Volume infusion, to increase preload and to enhance ventricular performance, is accepted as initial management of septic shock. Recent evidence has demonstrated depressed myocardial function in human septic shock. We analyzed left ventricular performance during volume infusion using serial data from simultaneously obtained pulmonary artery catheter hemodynamic measurements and radionuclide cineangiography. Critically ill control subjects (n = 14), patients with sepsis but without shock (n = 21), and patients with septic shock (n = 21) had prevolume infusion hemodynamic measurements determined and received statistically similar volumes of fluid resulting in similar increases in pulmonary capillary wedge pressure. There was a strong trend (p = 0.004) toward less of a change in left ventricular stroke work index (LVSWI) after volume infusion in patients with sepsis and septic shock compared with control subjects. The LVSWI response after volume infusion was significantly less in patients with septic shock when compared with critically ill control subjects (p less than 0.05). These data demonstrate significantly altered ventricular performance, as measured by LVSWI, in response to volume infusion in patients with septic shock

  3. Errors during MRT measurements of the left ventricular volume using a multi-slice technique

    International Nuclear Information System (INIS)

    Pitton, M.B.; Just, M.; Grebe, P.; Kreitner, K.F.; Erbel, R.; Thelen, M.

    1992-01-01

    A multi-slice technique for MRT measurements of the left ventricular volume is much faster than the use of single-slice methods and is therefore better tolerated, leaving time for additional measurements. The end-diastolic left ventricular volume can be reliably measured by this method (123.3±13.5 ml vs. 124.1±ml). The end-systolic volume is consistently overestimated by 23.7±18,3% compared with the reference value obtained by single slice measurements (47.9±8.9 ml vs 39.1±7.9 ml). Correspondingly, stroke volume and ejection fraction is underestimated on average by 10.6±9.7% and 10.6±7.6% respectively). (orig.) [de

  4. The repeatability of left ventricular volume assessment by a new ambulatory radionuclide monitoring system during head-up tilt

    International Nuclear Information System (INIS)

    Takase, Bonpei; Hosaka, Haruhiko; Kitamura, Katsuhiro

    2001-01-01

    The precise measurement of changes in left ventricular volume is important to elucidate the mechanisms of neurally mediated syncope. This study was conducted to determine whether or not a brand-new ambulatory radionuclide monitoring system (C-VEST system) can be clinically used to easily and precisely measure left ventricular volume and function in tilt testing. To assess the repeatability of the C-VEST system, 12 healthy volunteers (mean age 24±4 years old) underwent 20 minute head-up tilt testing and we measured the temporal changes in left ventricular volume and ejection fraction twice a day (first and second studies). To investigate the changes in the C-VEST measurements and the detector position in the first and second studies, tilt testing was performed with an 80-degree passive tilt, which is the same as the standard procedure used in diagnosing neurally mediated syncope. The coefficient of repeatability for both the C-VEST and detector position was well within the clinical range (coefficient of repeatability in left ventricular volume ranged from 1.7 to 2.8; coefficient of repeatability in the detector position ranged from 2.3 to 3.1). Precise evaluation of the left ventricular volume can be achieved by an ambulatory radionuclide monitoring system in tilt testing. (author)

  5. Evaluation of left ventricular function and volume with multidetector-row computed tomography. Comparison with electrocardiogram-gated single photon emission computed tomography

    International Nuclear Information System (INIS)

    Suzuki, Takeya; Yamashina, Shohei; Nanjou, Shuji; Yamazaki, Junichi

    2007-01-01

    This study compared left ventricular systolic function and volume determined by multidetector-row computed tomography (MDCT) and electrocardiogram-gated single photon emission computed tomography (G-SPECT) Thirty-seven patients with coronary artery disease and non-cardiovascular disease underwent MDCT. In this study, left ventricular ejection fraction (EF), left ventricular end-diastolic volume (EDV) and left ventricular end-systolic volume (ESV) were calculated using only two-phase imaging with MDCT. Left ventricular function and volume were compared using measurements from G-SPECT. We conducted MDCT and G-SPECT virtually simultaneously. Both the EF and ESV evaluated by MDCT closely correlated with G-SPECT (r=0.763, P 65 bpm) during MDCT significantly influenced the difference in EF calculated from MDCT and G-SPECT (P<0.05). Left ventricular function can be measured with MDCT as well as G-SPECT. However, a heart rate over 65 bpm during MDCT negatively affects the EF correlation between MDCT and G-SPECT. (author)

  6. Radionuclide determination of right and left ventricular stroke volumes

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Wei Feng; Roubin, G S; Choong, C Y.P.; Harris, P J; Flether, P J; Kelly, D T; Uren, R F; Hutton, B F

    1985-03-01

    The relationship between radionuclide and thermodilution measurement of stroke volumes (SV) was investigated in 30 patients without valvular regurgitation or intracardiac shunt (group A) at rest and during exercise. Both attenuated radionuclide right ventricular (RV) and left ventricular (LV) SV measurements correlated well with the SV determined by the thermodilution method (r = 0.87 and r = 0.93, all P < 0.001). The reliability of the radionuclide method to estimate SV was evaluated prospectively in two additional groups of patients. In 11 patients without valvular regurgitation or intracardiac shunt (group B) the radionuclide RVSV and LVSV closely approximated to thermodilution SV at rest and during exercise. In 15 patients with aortic regurgitation (group C) the radionuclide stroke volume ratio correlated well with the angiographic regurgitant fraction. Thus, both RVSV and LVSV and the severity of aortic regurgitation can be reliably measured with gated radionuclide ventriculography.

  7. Non-invasive measurement of stroke volume and left ventricular ejection fraction. Radionuclide cardiography compared with left ventricular cardioangiography

    DEFF Research Database (Denmark)

    Kelbaek, H; Svendsen, J H; Aldershvile, J

    1988-01-01

    The stroke volume (SV) was determined by first passage radionuclide cardiography and the left ventricular ejection fraction (LVEF) by multigated radionuclide cardiography in 20 patients with ischemic heart disease. The results were evaluated against those obtained by the invasive dye dilution or ...... are reliable. The discrepancy between the non-invasive and invasive LVEF values raises the question, whether LVEF is overestimated by cardioangiography or underestimated by radionuclide cardiography....

  8. Left ventricular function in chronic aortic regurgitation

    International Nuclear Information System (INIS)

    Iskandrian, A.S.; Hakki, A.H.; Manno, B.; Amenta, A.; Kane, S.A.

    1983-01-01

    Left ventricular performance was determined in 42 patients with moderate or severe aortic regurgitation during upright exercise by measuring left ventricular ejection fraction and volume with radionuclide ventriculography. Classification of the patients according to exercise tolerance showed that patients with normal exercise tolerance (greater than or equal to 7.0 minutes) had a significantly higher ejection fraction at rest (probability [p] . 0.02) and during exercise (p . 0.0002), higher cardiac index at exercise (p . 0.0008) and lower exercise end-systolic volume (p . 0.01) than did patients with limited exercise tolerance. Similar significant differences were noted in younger patients compared with older patients in ejection fraction at rest and exercise (both p . 0.001) and cardiac index at rest (p . 0.03) and exercise (p . 0.0005). The end-diastolic volume decreased during exercise in 60% of the patients. The patients with a decrease in volume were significantly younger and had better exercise tolerance and a larger end-diastolic volume at rest than did patients who showed an increase in volume. The mean corrected left ventricular end-diastolic radius/wall thickness ratio was significantly greater in patients with abnormal than in those with normal exercise reserve (mean +/- standard deviation 476 +/- 146 versus 377 +/- 92 mm Hg, p less than 0.05). Thus, in patients with chronic aortic regurgitation: 1) left ventricular systolic function during exercise was related to age, exercise tolerance and corrected left ventricular end-diastolic radius/wall thickness ratio, and 2) the end-diastolic volume decreased during exercise, especially in younger patients and patients with normal exercise tolerance or a large volume at rest

  9. Videodensitometric assessment of right and left ventricular functions by digital subtraction angiography

    International Nuclear Information System (INIS)

    Ikeda, Hisao; Yoshiga, Osamu; Shibao, Keigo

    1987-01-01

    Intravenous digital subtraction (DS) ventriculography was performed in a series of 50 patients with heart diseases to determine right and left ventricular volumes and systolic indices. Right ventricular volume and right ventricular ejection fraction obtained by DS ventriculography were well correlated with those by geometric methods. In 43 patients with left ventricular ejection fraction of 55 % or greater, end-diastolic volume, stroke volume, and ejection fraction in the right ventricle did not differ from those in the left ventricle ; however, both the 1/3 ejection fraction and the peak ejection rate of the right ventricle were significantly lower than those of the left ventricle, suggesting the different modes of left and right ventricular contraction. In the other seven patients with chronic left ventricular failure, right ventricular systolic function may be preserved, even when left ventricular function is severely impaired. Digital subtraction ventriculography has proved to be a simple, useful method in the quanlitative and quantitative assessments of the right and left ventricles. (Namekawa, K.)

  10. ECG-gated blood pool tomography in the determination of left ventricular volume, ejection fraction, and wall motion

    International Nuclear Information System (INIS)

    Underwood, S.R.; Ell, P.J.; Jarritt, P.H.; Emanuel, R.W.; Swanton, R.H.

    1984-01-01

    ECG-gated blood pool tomography promises to provide a ''gold standard'' for noninvasive measurement of left ventricular volume, ejection fraction, and wall motion. This study compares these measurements with those from planar radionuclide imaging and contrast ventriculography. End diastolic and end systolic blood pool images were acquired tomographically using an IGE400A rotating gamma camera and Star computer, and slices were reconstructed orthogonal to the long axis of the heart. Left ventricular volume was determined by summing the areas of the slices, and wall motion was determined by comparison of end diastolic and end systolic contours. In phantom experiments this provided an accurate measurement of volume (r=0.98). In 32 subjects who were either normal or who had coronary artery disease left ventricular volume (r=0.83) and ejection fraction (r=0.89) correlated well with those using a counts based planar technique. In 16 of 18 subjects who underwent right anterior oblique X-ray contrast ventriculography, tomographic wall motion agreed for anterior, apical, and inferior walls, but abnormal septal motion which was not apparent by contrast ventriculography, was seen in 12 subjects tomographically. All 12 had disease of the left anterior descending coronary artery and might have been expected to have abnormal septal motion. ECG-gated blood pool tomography can thus determine left ventricular volume and ejection fraction accurately, and provides a global description of wall motion in a way that is not possible from any single planar image

  11. Evaluation of right ventricular volumes measured by magnetic resonance imaging

    DEFF Research Database (Denmark)

    Møgelvang, J; Stubgaard, M; Thomsen, C

    1988-01-01

    stroke volume was calculated as the difference between end-diastolic and end-systolic volume and compared to left ventricular stroke volume and to stroke volume determined simultaneously by a classical indicator dilution technique. There was good agreement between right ventricular stroke volume......Right ventricular volumes were determined in 12 patients with different levels of right and left ventricular function by magnetic resonance imaging (MRI) using an ECG gated multisection technique in planes perpendicular to the diastolic position of the interventricular septum. Right ventricular...... determined by MRI and by the indicator dilution method and between right and left ventricular stroke volume determined by MRI. Thus, MRI gives reliable values not only for left ventricular volumes, but also for right ventricular volumes. By MRI it is possible to obtain volumes from both ventricles...

  12. Pressure-volume Relationship in the Stress-echocardiography Laboratory: Does (Left Ventricular End-diastolic) Size Matter?

    Science.gov (United States)

    Bombardini, Tonino; Mulieri, Louis A; Salvadori, Stefano; Costantino, Marco Fabio; Scali, Maria Chiara; Marzilli, Mario; Picano, Eugenio

    2017-02-01

    The variation between rest and peak stress end-systolic pressure-volume relation is an afterload-independent index of left ventricular contractility. Whether and to what extent it depends on end-diastolic volume remains unclear. The aim of this study was to assess the dependence of the delta rest-stress end-systolic pressure-volume relation on end-diastolic volume in patients with negative stress echo and all ranges of resting left ventricular function. We analyzed interpretable data obtained in 891 patients (593 men, age 63 ± 12 years) with ejection fraction 47% ± 12%: 338 were normal or near-normal or hypertensive; 229 patients had coronary artery disease; and 324 patients had ischemic or nonischemic dilated cardiomyopathy. They were studied with exercise (n = 172), dipyridamole (n = 482) or dobutamine (n = 237) stress echocardiography. The end-systolic pressure-volume relation was evaluated at rest and peak stress from raw measurement of systolic arterial pressure by cuff sphygmomanometer and end-systolic volume by biplane Simpson rule 2-dimensional echocardiography. Absolute values of delta rest-stress end-systolic pressure-volume relation were higher for exercise and dobutamine than for dipyridamole. In the overall population, an inverse relationship between end-systolic pressure-volume relation and end-diastolic volume was present at rest (r 2 = 0.69, P stress (r 2 = 0.56, P stress end-systolic pressure-volume relation was considered (r 2 = 0.13). Left ventricular end-diastolic volume does not affect the rest-stress changes in end-systolic pressure-volume relation in either normal or abnormal left ventricles during physical or pharmacological stress. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  13. Count-based left ventricular volume determination utilizing a left posterior oblique view for attenuation correction

    International Nuclear Information System (INIS)

    Rabinovitch, M.A.; Kalff, V.; Koral, K.

    1984-01-01

    This study aimed to determine the inherent error of the left ventricular volume measurement from the gated equilibrium blood pool scintigram utilizing the count-based technique. The study population consisted of 26 patients who had undergone biplane contrast ventriculography. The patients were imaged with a parallel-hole collimator in the left anterior oblique position showing the septum to best advantage. A reference blood sample was counted and radionuclide volumes calculated without correction for attenuation. Attenuation corrected volumes were derived with the factor 1/e/sup -/+d/, where d = distance from skin marker to center of the left ventricle in the orthogonal left posterior oblique view and μ = linear attenuation coefficient. A series of μ values from 0.08 to 0.15 cm -1 was evaluated. The tightest 95% confidence limits achieved for an end-diastolic 150-ml ventricle were +/- 44ml, and for an end-systolic 75-ml ventricle +/- 32 ml. In view of the magnitude of inherent error, the count-based volume measurement may be more suitable for group analyses and in cases in which an individual patient serves as his own control

  14. Independence of intrapericardial right and left ventricular performance in septic pulmonary hypertension

    International Nuclear Information System (INIS)

    Boeck, J.C.; Eichstaedt, H.; Barker, B.C.; Lewis, F.R.; Lim, A.D.; Pollycove, M.

    1990-01-01

    To study the effect of septic pulmonary hypertension on right/left ventricular intrapericardial interactions thirteen trauma patients, seven septic and six nonseptic controls, were compared. Ventricular volumes were derived from firstpass or gated equilibrium radionuclide angiocardiography, and related to body surface area. Systemic and pulmonary pressures were measured invasively. Pulmonary arterial pressure was significantly increased in the sepsis group. Although right ventricular end-diastolic volumes were higher in sepsis, left ventricular end-diastolic volumes were not decreased. In terms of intrapericardial right/left ventricular interactions these results indicate that the right and left ventricles operate independently in septic pulmonary hypertension. (orig.) [de

  15. Relation Between Pressure and Volume Unloading During Ramp Testing in Patients Supported with a Continuous-Flow Left Ventricular Assist Device

    DEFF Research Database (Denmark)

    Jung, Mette H; Hassager, Christian; Balling, Louise

    2015-01-01

    Pulmonary capillary wedge pressure (PCWP) is the key to describing left ventricular (LV) unloading, however, the relation between pressure and the echocardiography-derived surrogate of LV volume (left ventricular end-diastolic diameter (LVEDD)) as a function of pump speed (RPM) in continuous......-flow left ventricular assist device (CF-LVAD) patients is unknown. In this study the pressure-volume relationship as a function of RPM during ramp testing was investigated by simultaneously measuring PCWP by Swan-Ganz catheter and LVEDD by echocardiography. The ramp protocol started at usual pump setting...

  16. Evaluation of left ventricular function by cardiac CT

    International Nuclear Information System (INIS)

    Naito, Hiroaki; Kozuka, Takahiro

    1982-01-01

    Left ventricular function was evaluated by CT, which was compared with the data of left ventriculography for various cardiac diseases. The end diastolic volume of the left ventricle can be readily computed from CT, with a satisfactory correlation with that of left ventriculography (r = 0.95). The left ventricular ejection fraction, calculated from the areal ratio of the left ventricular lumen in end-diastolic imaging to that in end-sytolic imaging, also roughly reflects left ventricular contractile function, but shows correlation with left ventriculography by only r = 0.79. Although the cardiac output is not sensitive for functional evaluation, it can be directly calculated by means of dynamic scanning and shows a satisfactory correlation with the ear piece pigment dilution (r = 0.85). Evaluation of left ventricular function by CT shows a high precision in comparison with left ventriculography, but still lacks temporal resolving power. (Chiba, N.)

  17. Effects of verapamil on left ventricular systolic and diastolic function in patients with hypertrophic cardiomyopathy: pressure-volume analysis with a nonimaging scintillation probe.

    Science.gov (United States)

    Bonow, R O; Ostrow, H G; Rosing, D R; Cannon, R O; Lipson, L C; Maron, B J; Kent, K M; Bacharach, S L; Green, M V

    1983-11-01

    To investigate the effects of verapamil on left ventricular systolic and diastolic function in patients with hypertrophic cardiomyopathy, we studied 14 patients at catheterization with a nonimaging scintillation probe before and after serial intravenous infusions of low-, medium-, and high-dose verapamil (total dose 0.17 to 0.72 mg/kg). Percent change in radionuclide stroke counts after verapamil correlated well with percent change in thermodilution stroke volume (r = .87), and changes in diastolic and systolic counts were used to assess relative changes in left ventricular volumes after verapamil. Verapamil produced dose-related increases in end-diastolic counts (19 +/- 9% increase; p less than .001), end-systolic counts (91 +/- 54% increase; p less than .001), and stroke counts (7 +/- 10% increase; p less than .02). This was associated with a decrease in ejection fraction (83 +/- 8% control, 73 +/- 10% verapamil; p less than .001) and, in the 10 patients with left ventricular outflow tract gradients, a reduction in gradient (62 +/- 27 mm Hg control, 32 +/- 35 mm Hg verapamil; p less than .01). The end-systolic pressure-volume relation was shifted downward and rightward in all patients, suggesting a negative inotropic effect. In 10 patients, left ventricular pressure-volume loops were constructed with simultaneous micromanometer pressure recordings and the radionuclide time-activity curve. In five patients, verapamil shifted the diastolic pressure-volume curve downward and rightward, demonstrating improved pressure-volume relations despite the negative inotropic effect, and also increased the peak rate of rapid diastolic filling. In the other five patients, the diastolic pressure-volume relation was unaltered by verapamil, and increased end-diastolic volumes occurred at higher end-diastolic pressures; in these patients, the peak rate of left ventricular diastolic filling was not changed by verapamil. The negative inotropic effects of intravenous verapamil are

  18. Pre-chemotherapy values for left and right ventricular volumes and ejection fraction by gated tomographic radionuclide angiography using a cadmium-zinc-telluride detector gamma camera

    DEFF Research Database (Denmark)

    Haarmark, Christian; Haase, Christine; Jensen, Maria Maj

    2016-01-01

    age and both left and right ventricular volumes in women (r = -0.4, P right end systolic ventricular volume in men (r = -0.3, P = .001). CONCLUSION: A set of reference values for cardiac evaluation prior to chemotherapy in cancer patients without other known cardiopulmonary......BACKGROUND: Estimation of left ventricular ejection fraction (LVEF) using equilibrium radionuclide angiography is an established method for assessment of left ventricular function. The purpose of this study was to establish normative data on left and right ventricular volumes and ejection fraction......, using cadmium-zinc-telluride SPECT camera. METHODS AND RESULTS: From routine assessments of left ventricular function in 1172 patients, we included 463 subjects (194 men and 269 women) without diabetes, previous potentially cardiotoxic chemotherapy, known cardiovascular or pulmonary disease. The lower...

  19. New strict left bundle branch block criteria reflect left ventricular activation differences

    DEFF Research Database (Denmark)

    Emerek, Kasper Janus Grønn; Risum, Niels; Hjortshøj, Søren Pihlkjær

    2015-01-01

    AIMS: Pacing lead electrical delays and strict left bundle branch block (LBBB) criteria were assessed against cardiac resynchronization therapy (CRT) outcome. METHODS: Forty-nine patients with LBBB and QRS duration >130 milliseconds underwent CRT-implantation. Sensed right ventricular to left ven....... CONCLUSION: Interventricular electrical delay predicts left ventricular remodeling after CRT and new, strict ECG criteria of LBBB are superior in predicting remodeling.......AIMS: Pacing lead electrical delays and strict left bundle branch block (LBBB) criteria were assessed against cardiac resynchronization therapy (CRT) outcome. METHODS: Forty-nine patients with LBBB and QRS duration >130 milliseconds underwent CRT-implantation. Sensed right ventricular to left...... ventricular electrical delay (RV-LV-IED) was measured. Response to CRT was defined as ≥15% decrease in left ventricular end-systolic volume. RESULTS: Eighteen of 20 (90%) patients with non-ischemic dilated cardiomyopathy (DCM) and 18 of 29 (62%) with ischemic heart disease (IHD) responded to CRT, p

  20. Quantitation of right and left ventricular volume with MR imaging in patients with primary pulmonary hypertension

    International Nuclear Information System (INIS)

    Boxt, L.M.; Katz, J.; Kolb, T.; Czegledy, F.P.; Barst, R.J.

    1990-01-01

    This paper tests the utility of MR imaging in quantitating changes in ventricular volume and function in patients with primary pulmonary hypertension (PPH). Right ventricular (RV) and left ventricular (LV) end-diastolic (ED) and end-systolic (ES) volumes were determined in six patients with PPH and in eight controls. Short-axis images were obtained from the cardiac apex to the base at ED and ES, and the ventricular cavities were planimetered. Volumes were computed by summing the areas of the cavities times the thickness of the sections (12-14 mm). The intersection gap (1-3 mm) was averaged between adjacent sections. Results were indexed to the subject's body surface area. This technique was verified by comparison of results obtained by this method with the water displacement volumes of ventricular casts of eight excised bovine hearts and six water-filled balloons. Linear regression and the unpaired Students t test were used to test significance

  1. Measurement of left ventricular volume by biplane cine magnetic resonance imaging in children

    Energy Technology Data Exchange (ETDEWEB)

    Ichida, Fukiko; Hamamichi, Yuuji; Hashimoto, Ikuo; Tsubata, Shinichi; Miyazaki, Ayumi; Okada, Toshio; Murakami, Arata; Futatsuya, Ryuusuke (Toyama Medical and Pharmaceutical Univ. (Japan))

    1993-09-01

    To determine the ability of cine magnetic resonance imaging (MRI) to assess left ventricular (LV) volumes, we studied 20 children (age 4 months to 10 years) with various heart disease, validated by comparison with biplane LV angiography. Previous MRI studies to assess LV volumes have used multiple axial planes, which are compromised by partial volume effects and are time consuming to acquire and analyze. Accordingly, an imaging approach using biplane cine MRI and planes aligned with the true cardiac axes (the intrinsic long and short axis) of the LV was developed in views comparable with biplane LV angiography. In all patients, LV volumes were calculated by a Simpson's rule algorithm, both in MRI and LV angiography. MRI determined LV volumes were slightly underestimated but correlated reasonably well with angiographic values (LVEDV: Y=0.88X + 1.58, R=0.98, LVESV: Y=0.72X + 1.02, R=0.98). Especially, even in the patients who have abnormal left ventricular geometry such as Tetralogy of Fallot, MRI determined LV volumes correlated well with angiographic values. It is concluded that biplane cine MRI, using the intrinsic LV long and short axis planes, permits noninvasive assessment of LV volumes in views comparable to standard angiographic projections and appears practical for clinical use in childhood heart disease, because the scan and analysis time are relatively short. (author).

  2. Measurement of left ventricular volume by biplane cine magnetic resonance imaging in children

    Energy Technology Data Exchange (ETDEWEB)

    Ichida, Fukiko; Hamamichi, Yuuji; Hashimoto, Ikuo; Tsubata, Shinichi; Miyazaki, Ayumi; Okada, Toshio; Murakami, Arata; Futatsuya, Ryuusuke [Toyama Medical and Pharmaceutical Univ. (Japan)

    1993-09-01

    To determine the ability of cine magnetic resonance imaging (MRI) to assess left ventricular (LV) volumes, we studied 20 children (age 4 months to 10 years) with various heart disease, validated by comparison with biplane LV angiography. Previous MRI studies to assess LV volumes have used multiple axial planes, which are compromised by partial volume effects and are time consuming to acquire and analyze. Accordingly, an imaging approach using biplane cine MRI and planes aligned with the true cardiac axes (the intrinsic long and short axis) of the LV was developed in views comparable with biplane LV angiography. In all patients, LV volumes were calculated by a Simpson's rule algorithm, both in MRI and LV angiography. MRI determined LV volumes were slightly underestimated but correlated reasonably well with angiographic values (LVEDV: Y=0.88X + 1.58, R=0.98, LVESV: Y=0.72X + 1.02, R=0.98). Especially, even in the patients who have abnormal left ventricular geometry such as Tetralogy of Fallot, MRI determined LV volumes correlated well with angiographic values. It is concluded that biplane cine MRI, using the intrinsic LV long and short axis planes, permits noninvasive assessment of LV volumes in views comparable to standard angiographic projections and appears practical for clinical use in childhood heart disease, because the scan and analysis time are relatively short. (author).

  3. Measurement of left ventricular volume by biplane cine magnetic resonance imaging in children

    International Nuclear Information System (INIS)

    Ichida, Fukiko; Hamamichi, Yuuji; Hashimoto, Ikuo; Tsubata, Shinichi; Miyazaki, Ayumi; Okada, Toshio; Murakami, Arata; Futatsuya, Ryuusuke

    1993-01-01

    To determine the ability of cine magnetic resonance imaging (MRI) to assess left ventricular (LV) volumes, we studied 20 children (age 4 months to 10 years) with various heart disease, validated by comparison with biplane LV angiography. Previous MRI studies to assess LV volumes have used multiple axial planes, which are compromised by partial volume effects and are time consuming to acquire and analyze. Accordingly, an imaging approach using biplane cine MRI and planes aligned with the true cardiac axes (the intrinsic long and short axis) of the LV was developed in views comparable with biplane LV angiography. In all patients, LV volumes were calculated by a Simpson's rule algorithm, both in MRI and LV angiography. MRI determined LV volumes were slightly underestimated but correlated reasonably well with angiographic values (LVEDV: Y=0.88X + 1.58, R=0.98, LVESV: Y=0.72X + 1.02, R=0.98). Especially, even in the patients who have abnormal left ventricular geometry such as Tetralogy of Fallot, MRI determined LV volumes correlated well with angiographic values. It is concluded that biplane cine MRI, using the intrinsic LV long and short axis planes, permits noninvasive assessment of LV volumes in views comparable to standard angiographic projections and appears practical for clinical use in childhood heart disease, because the scan and analysis time are relatively short. (author)

  4. Normalised radionuclide measures of left ventricular diastolic function

    International Nuclear Information System (INIS)

    Lee, K.J.; Southee, A.E.; Bautovich, G.J.; Freedman, B.; McLaughlin, A.F.; Rossleigh, M.A.; Hutton, B.F.; Morris, J.G.; Royal Prince Alfred Hospital, Sydney

    1989-01-01

    Abnormal left ventricular diastolic function is being increasingly recognised in patients with clinical heart failure and normal systolic function. A simple routine radionuclide measure of diastolic function would therefore be useful. To establish, the relationship of peak diastolic filling rate (normalized for either end diastolic volume, stroke volume, or peak systolic emptying rate), and heart rate, age, and left ventricular ejection fraction was studied in 64 subjects with normal cardiovascular systems using routine gated heart pool studies. The peak filling rate when normalized to end diastolic volume correlated significantly with heart rate, age and left ventricular ejection fraction, whereas normalization to stroke volume correlated significantly to heart rate and age but not to left ventricular ejection fraction. Peak filling rate normalized for peak systolic emptying rate correlated with age only. Multiple regression equations were determined for each of the normalized peak filling rates in order to establish normal ranges for each parameter. When using peak filling rate normalized for end diastolic volume or stroke volume, appropriate allowance must be made for heart rate, age and ejection fraction. Peak filling rate normalized to peak ejection rate is a heart rate independent parameter which allows the performance of the patient's ventricle in diastole to be compared with its systolic function. It may be used in patients with normal systolic function to serially follow diastolic function, or if age corrected to screen for diastolic dysfunction. (orig.)

  5. Evaluation of left ventricular volumes in patients with congenital heart disease and abnormal left ventricular geometry. Comparison of MRI and transthoracic 3-dimensional echocardiography

    International Nuclear Information System (INIS)

    Gutberlet, M.; Grothoff, M.; Roettgen, R.; Lange, P.; Felix, R.; Abdul-Khaliq, H.; Schroeter, J.; Schmitt, B.; Vogel, M.

    2003-01-01

    Purpose: To assess the new method of 3-dimensional echocardiography in comparison to the 'gold standard' MRI as to its ability to calculate left ventricular volumes in patients with congenital heart disease. Materials and methods: Eighteen patients between the ages of 3.9 to 37.3 years (mean: 12.8±9.7) with a geometrically abnormal left ventricle were examined using a 1.5 T scanner with a fast gradient-echo sequence (TR=14 ms, TE=2.6-2.9 ms, FOV=300-400 mm, flip angle=20 , matrix=128:256, slice thickness=5 mm, retrospective gating) in multislice-multiphase technique. Transthoracic 3D-echocardiography was performed with a 3.5 MHz transducer and a Tomtec trademark (Munich, Germany) system for 3D reconstruction. Results: Volume calculation was possible in all patients with 3D-echocardiography, but the muscle mass calculation only succeeded in 11 to 18 patients (61%) due to inadequate visualization of the entire myocardium. Comparing MRI and 3D-echocardiography, the correlation was r=0.97 for the end-systolic volumes, r=0.98 for the end-diastolic volumes, r=0.79 for the end-systolic muscle mass and r=0.77 for the end-diastolic muscle mass. The agreement between both methods was considered good for the calculated end-diastolic volumes and sufficient for the calculated end-systolic volumes. The muscle mass calculations showed larger differences especially for the end-systolic mass. Mean intraobserver variability was 18.6% for end-systolic and 8.3% for end-diastolic volumes. Conclusion: In patients with an abnormal left ventricular configuration due to congenital heart disease, the new method of 3D-echocardiography is sufficient for volume calculations in preselected patients. The high intraobserver variability is still a limitation of transthoracic 3D-echocardiography in comparison to MRI. (orig.) [de

  6. Feasibility of the left ventricular volume measurement by acoustic quantification method. Comparison with ultrafast computed tomography

    International Nuclear Information System (INIS)

    Tomimoto, Shigehiro; Nakatani, Satoshi; Tanaka, Norio; Uematsu, Masaaki; Beppu, Shintaro; Nagata, Seiki; Hamada, Seiki; Takamiya, Makoto; Miyatake, Kunio

    1995-01-01

    Acoustic quantification (AQ: the real-time automated boundary detection system) allows instantaneous measurement of cardiac chamber volumes. The feasibility of this method was evaluated by comparing the left ventricular (LV) volumes obtained with AQ to those derived from ultrafast computed tomography (UFCT), which enables accurate measurements of LV volumes even in the presence of LV asynergy, in 23 patients (8 with ischemic heart disease, 5 with cardiomyopathy, 3 with valvular heart disease). Both LV end-diastolic and end-systolic volumes obtained with the AQ method were in good agreement with those obtained with UFCT (y=1.04χ-16.9, r=0.95; y=0.87χ+15.7, r=0.91; respectively). AQ was reliable even in the presence of LV asynergy. Interobserver variability for the AQ measurement was 10.2%. AQ provides a new, clinically useful method for real-time accurate estimation of the left ventricular volume. (author)

  7. Feasibility of the left ventricular volume measurement by acoustic quantification method. Comparison with ultrafast computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tomimoto, Shigehiro; Nakatani, Satoshi; Tanaka, Norio; Uematsu, Masaaki; Beppu, Shintaro; Nagata, Seiki; Hamada, Seiki; Takamiya, Makoto; Miyatake, Kunio [National Cardiovascular Center, Suita, Osaka (Japan)

    1995-01-01

    Acoustic quantification (AQ: the real-time automated boundary detection system) allows instantaneous measurement of cardiac chamber volumes. The feasibility of this method was evaluated by comparing the left ventricular (LV) volumes obtained with AQ to those derived from ultrafast computed tomography (UFCT), which enables accurate measurements of LV volumes even in the presence of LV asynergy, in 23 patients (8 with ischemic heart disease, 5 with cardiomyopathy, 3 with valvular heart disease). Both LV end-diastolic and end-systolic volumes obtained with the AQ method were in good agreement with those obtained with UFCT (y=1.04{chi}-16.9, r=0.95; y=0.87{chi}+15.7, r=0.91; respectively). AQ was reliable even in the presence of LV asynergy. Interobserver variability for the AQ measurement was 10.2%. AQ provides a new, clinically useful method for real-time accurate estimation of the left ventricular volume. (author).

  8. The study of alteration in left ventricular volume and pressure to volume ratio during exercise in patients with coronary heart disease

    International Nuclear Information System (INIS)

    Liu Zhonglin; Pei Zhuguo; Zang Bin

    1994-01-01

    The alterations induced by exercise in left ventricular end diastolic volume index (EDVI), end systolic volume index (ESVI) and systolic blood pressure to end systolic volume ratio (P/ESV) were studied in 15 normal subjects and 42 patients with coronary heart disease using a non-geometric count-based method and supine bicycle exercise test. Normal subjects had an increase in EDVI and a decrease in ESVI, but coronary heart disease patients had an increase in both EDVI and ESVI. The extent of increase induced by exercise in EDVI was greater in angina patients than that in normal and old myocardial infarction subjects. The P/ESV can be used to evaluate left ventricular systolic pressure-volume relationship. For the P/ESV exercise response, the sensitivity, specificity and accuracy for coronary heart disease were 95%, 93% and 95%, respectively

  9. Evaluation of the accuracy of ventricular volume measurement by ultrafast CT

    International Nuclear Information System (INIS)

    Cui Wei; Dai Ruping; Guo Yuyin

    1997-01-01

    The authors evaluated the accuracy of ventricular volume measured by ultrafast CT (UFCT); and (2) compared the value of ventricular volume derived from long- and short-axis view. Fourteen human left ventricular casts and 15 right ventricular casts were scanned by Imatron C-150 scanner along both the long- and short-axis. The scan protocol was similar to that used in vivo. Eight 7 mm-thick slices were obtained from each cast for both long- and short-axis views. Ventricular volume was determined by the modified Simpson's rule provided by Inamtron Inc. The actual volumes of the ventricular casts were determined by the amount of water displacement by the cast. The actual volumes for left and right ventricles were 55.57 +- 28.91 ml and 64.23 +- 24.51 ml, respectively, the left and right ventricular volumes determined by UFCT were 66.50 +- 33.04 ml and 76.47 +-28.70 ml from long-axis view, and 60.36 +- 29.90 ml and 75.36 +- 28.73 ml from short-axis view, respectively. The measurements by UFCT were significantly greater than the actual volumes of the casts, both for the left and right ventricles (P 0.990). Both left and right ventricular volumes can be determined by UFCT with identical accuracy for both long- and short-axis views in calculating ventricular volume; however, overestimation of ventricular volume by UFCT should be noted

  10. Assessment of vasodilator therapy in patients with severe congestive heart failure: limitations of measurements of left ventricular ejection fraction and volumes

    International Nuclear Information System (INIS)

    Firth, B.G.; Dehmer, G.J.; Markham, R.V. Jr.; Willerson, J.T.; Hillis, L.D.

    1982-01-01

    Although noninvasive techniques are often used to assess the effect of vasodilator therapy in patients with congestive heart failure, it is unknown whether changes in noninvasively determined left ventricular ejection fraction, volume, or dimension reliably reflect alterations in intracardiac pressure and flow. Accordingly, we compared the acute effect of sodium nitroprusside on left ventricular volume and ejection fraction (determined scintigraphically) with its effect on intracardiac pressure and forward cardiac index (determined by thermodilution) in 12 patients with severe, chronic congestive heart failure and a markedly dilated left ventricle. Nitroprusside (infused at 1.3 +/- 1.1 [mean +/- standard deviation] microgram/kg/min) caused a decrease in mean systemic arterial, mean pulmonary arterial, and mean pulmonary capillary wedge pressure as well as a concomitant increase in forward cardiac index. Simultaneously, left ventricular end-diastolic and end-systolic volume indexes decreased, but the scintigraphically determined cardiac index did not change significantly. Left ventricular ejection fraction averaged 0.19 +/- 0.05 before nitroprusside administration and increased by less than 0.05 units in response to nitroprusside in 11 of 12 patients. The only significant correlation between scintigraphically and invasively determined variables was that between the percent change in end-diastolic volume index and the percent change in pulmonary capillary wedge pressure (r . 0.68, p . 0.01). Although nitroprusside produced changes in scintigraphically determined left ventricular ejection fraction, end-systolic volume index, and cardiac index, these alterations bore no predictable relation to changes in intracardiac pressure, forward cardiac index, or vascular resistance. Furthermore, nitroprusside produced a considerably greater percent change in the invasively measured variables than in the scintigraphically determined ones

  11. Relation of left ventricular function, mass, and volume to NT-proBNP in type 1 diabetic patients

    DEFF Research Database (Denmark)

    Astrup, A.S.; Kim, W.Y.; Tarnow, L.

    2008-01-01

    OBJECTIVES: To measure left ventricular mass (LVM), left ventricular volumes, and left ventricular function (LVF) in a cohort of type 1 diabetic patients and to correlate measures of imaging to NH(2)-terminal pro-brain natriuretic peptide (NT-proBNP). RESEARCH DESIGN AND METHODS: In a cross......-sectional study, all patients with type 1 diabetes underwent cardiovascular magnetic resonance imaging. We included 63 patients with diabetic nephropathy and 73 patients with normoalbuminuria. RESULTS: All patients had normal global LVF. LVM was increased in patients with diabetic nephropathy compared...... is identified in asymptomatic type 1 diabetic patients with nephropathy compared with normoalbuminuric patients. Elevated levels of NT-proBNP were associated with increased LVM, which are both markers of increased cardiovascular risk Udgivelsesdato: 2008/5...

  12. Applications of magnetic resonance imaging in the assessment of left ventricular dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Beacock, David John

    2002-07-01

    This thesis has described the use of Magnetic Resonance Imaging (MRI) in the investigation of left ventricular dimensions and systolic function. This has been performed in conditions of left ventricular dysfunction, in congestive cardiac failure and following anterior myocardial infarction. The reproducibility of measurements of left ventricular dimensions using MRI has been presented. Such measurements were shown to be reproducible between different MRI studies of normal volunteers and patients with congestive heart failure. Furthermore, measurements from different MRI studies obtained from two commercially different systems were reproducible for the same subject groups. Ventricular dimensions and systolic function was evaluated in adult normal volunteers of different ages. Although left ventricular volumes and mass remained unchanged, detailed studies of the systolic images revealed significant differences between the two age groups. Differences in left ventricular cavity volumes and mass between patients with congestive heart failure and age-matched normal volunteers were also investigated. Left ventricular volumes and myocardial mass were assessed in a group of patients following anterior myocardial infarction. End-systolic volume was significantly increased compared to age-matched volunteers, but no changes in end-diastolic volume or myocardial mass was observed. Serial re-evaluation of these patients revealed no other changes over the subsequent six months. All these patients were treated with optimal medical therapy (thrombolysis, aspirin, beta-blockade and angiotensin converting enzyme inhibition). Thus, the use of this therapy may attenuate the process of left ventricular remodelling. Regional wall thickness was measured in the post-infarct patients. Wall thickening was significantly reduced both in the infarcted regions and in myocardium remote to the infarction. In contrast to previous echocardiographic studies, no 'hypercontractility' was

  13. Prediction of acute cardiac rejection by changes in left ventricular volumes

    International Nuclear Information System (INIS)

    Novitzky, D.; Cooper, D.K.; Boniaszczuk, J.

    1988-01-01

    Sixteen patients underwent heart transplantation (11 orthotopic, five heterotopic). Monitoring for acute rejection was by both endomyocardial biopsy (EMB) and multigated equilibrium blood pool scanning with technetium 99m-labelled red blood cells. From the scans information was obtained on left ventricular volumes (stroke, end-diastolic, and end-systolic), ejection fraction, and heart rate. Studies (208) were made in the 16 patients. There was a highly significant correlation between the reduction in stroke volume and end-diastolic volume (and a less significant correlation in end-systolic volume) and increasing acute rejection seen on EMB. Heart rate and ejection fraction did not correlate with the development of acute rejection. Correlation of a combination of changes in stroke volume and end-diastolic volume with EMB showed a sensitivity of 85% and a specificity of 96%. Radionuclide scanning is therefore a useful noninvasive tool for monitoring acute rejection

  14. Influence of age on left ventricular performance during exercise in normal Japanese subject

    International Nuclear Information System (INIS)

    Konishi, Tokuji; Koyama, Takao; Aoki, Toshikazu; Makino, Katsutoshi; Yamamuro, Masashi; Nakai, Kyudayu; Nakamura, Masayuki; Nakano, Takeshi.

    1990-01-01

    To assess the effects of age on left ventricular performance, multistage supine ergometer exercise radionuclide ventriculography (RNV) was performed in 92 normal subjects. The subjects ranged in age from 24 to 86 years and were free of cardiopulmonary disease and diabetes. Age-related changes in exercise duration, left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV), cardiac output (CO) left ventricular ejection fraction (LVEF), left ventricular dv/dt, systolic and diastolic time indexes of dv/dt, and peak systolic pressure/left ventricular end-systolic volume (PSP/LVESV) were analyzed at rest and during the peak exercise stage. Age-related decrease in LVEDV and peak diastolic dv/dt were significant at rest. The time indexes of ECG R to peak systolic dv/dt and time of end-systole to peak diastolic dv/dt also were prolonged with age. Both maximum heart rate and exercise duration were shown to decline with age. No age-related difference was observed in LVESV, LVEF or PSP/LVESV either at rest or during exercise. However, the change of LVEF and LVESV during exercise was less in subjects aged 60 or more. These results indicate decreased left ventricular function during exercise in elderly subjects. (author)

  15. Myocardial perfusion SPECT for assessment of left ventricular function and volume- comparison with echocardiography

    International Nuclear Information System (INIS)

    Cheng Xu; Huang Gang

    2004-01-01

    Objective: The purpose of this study was to evaluate left ventricular volume and function by gated SPECT and comparison of the results with echocardiography. Methods: 65 Consecutive patients (49 male, 16 female; mean age 61+11 years) who underwent both gated 99m Tc-MIBI myocardial perfusion SPECT and echocardiography within a 15 days period were included in the study. Exclusion criteria were any change in clinical status between acquisition of the gated SPECT and echocardiography studies, acute myocardial infarction occurring less than 7 days before study, and surgical procedures occurring within 30 days of the study. The clinical diagnosis of each patient was not considered, as this was not relevant to the purpose of the study. The diagnoses were as follows: coronary artery disease (n=46), hypertensive heart disease (n=8), old myocardial infarction (n=5), myocarditis (n=2), and routine medical examination(n=4). A dose of 740 MBq of 99 Tc m -sestamibi was administered in resting condition. Gated SPECT images were obtained with ADAC Vertex MCD-AC SPECT system. The raw projection images were reconstructed with filtered back-projection (ramp filter), without attenuation correction. The data, including left ventricular ejection fraction (LVEF), end-diastolic volume (EDV), end-systolic volume (ESV) were obtained using AUTOQUANT software (ADAC corporation). The echocardiography study used its standard techniques. Two nuclear medicine physicians processed the raw images respectively to evaluate internal reproducibility of gated SPECT. In order to compare the results of gated SPECT with echocardiography on different left ventricular volumes, all patients were divided into two groups (EDV 90 ml, n=34) based by EDV measurements in echocardiography. Results: The correlation coefficient of LVEF, EDV, ESV between SPECT and echocardiography were 0.77, 0.86 and 0.90 respectively. P 0.07). The reproducibility of gated SPECT was excellent. There were no significant differences in

  16. Radionuclide evaluation of left ventricular function with nonimaging probes.

    Science.gov (United States)

    Wexler, J P; Blaufox, M D

    1979-10-01

    Portable nonimaging probes have been developed that can evaluate left ventricular function using radionuclide techniques. Two modes of data acquisition are possible with these probe systems, first-pass and gated. Precordial radiocardiograms obtained after a bolus injection can be used to determine cardiac output, pulmonary transit time, pulmonary blood volume, left ventricle ejection fraction, and left-to-right shunts. Gated techniques can be used to determine left ventricular ejection fraction and sytolic time intervals. Probe-determined indices of left ventricular function agree excellently with comparable measurements determined by conventional camera-computer methods as well as by invasive techniques. These have begun to be used in a preliminary manner in a variety of clinical problems associated with left ventricular dysfunction. This review discusses the types of probe systems available, the methods used in positioning them, and details the specifics of their data acquisition and processing capacity. The major criticisms of probe methods are that they are nonimaging and that they measure global rather than regional left ventricular function. In spite of these criticisms, probe systems, because of their portability, high sensitivity, and relatively low cost are useful supplements to conventional camera-computer systems for the measurement of parameters of left ventricular performance using radionuclide techniques.

  17. Continuous monitoring of left ventricular function by VEST

    International Nuclear Information System (INIS)

    Ohtake, Tohru; Watanabe, Toshiaki; Kosaka, Noboru

    1988-01-01

    Using an ambulatory ventricular function monitor (VEST), left ventricular function (LVF) was examined in one healthy volunteer, 3 with ischemic heart disease, and one with dilated myocardiopathy (DMCP) under various conditions, such as treadmill exercise, standing, and sitting. It was also examined when two DCMP patients with associated left ventricular failure were given a nitrite (ISDM) and cardiotonic agent (E 1020). End-diastolic volume (EDV) decreased in the standing position, and increased in exercise, suggesting the involvement of venous blood pool in the legs. Ejection fraction (EF) decreased in the case of widespread ischemia during exercise. Drug tolerance test revealed decrease in EDV and end-systolic volume (ESV), no change in stroke volume (SV), and slight increase in EF on ISDM; and decrease in EDV and ESV, increase in SV, and marked increase in EF on E 1020. For EF, the VEST data were relatively well correlated with gamma camera data. (Namekawa, K.)

  18. Left ventricular performance during psychological stress

    International Nuclear Information System (INIS)

    Young, D.Z.; Massachusetts General Hospital, Boston; Dimsdale, J.E.; Moore, R.H.; Barlai-Kovach, M.; Newell, J.B.; McKusick, K.A.; Boucher, C.A.; Fifer, M.A.; Strauss, H.W.

    1989-01-01

    Left ventricular ejection fraction, systolic blood pressure and plasma norepinephrine were measured in six normotensive and six mildly hypertensive subjects during rest and psychological stress. Compared with rest, 8 of the 12 subjects developed significant changes in ejection fraction (increase in 6, decrease in 2); 10 of 12 subjects developed significant elevations of plasma norepinephrine; and all developed significant increases in systolic blood pressure. When the stress effects were examined for the total group, as opposed to within subjects, there were significant increases in plasma norepinephrine and systolic blood pressure but, interestingly, mean ejection fraction and stroke volume remained unchanged, implying stress led to increased left ventricular contractility. (orig.)

  19. Exploratory assessment of left ventricular strain–volume loops in severe aortic valve diseases

    Science.gov (United States)

    Hulshof, Hugo G.; van Dijk, Arie P.; George, Keith P.; Hopman, Maria T. E.; Thijssen, Dick H. J.

    2017-01-01

    Key points Severe aortic valve diseases are common cardiac abnormalities that are associated with poor long‐term survival.Before any reduction in left ventricular (LV) function, the left ventricle undergoes structural remodelling under the influence of changing haemodynamic conditions.In this study, we combined temporal changes in LV structure (volume) with alterations in LV functional characteristics (strain, ԑ) into a ԑ–volume loop, in order to provide novel insight into the haemodynamic cardiac consequences of aortic valve diseases in those with preserved LV ejection fraction.We showed that our novel ԑ–volume loop and the specific loop characteristics provide additional insight into the functional and mechanical haemodynamic consequences of severe aortic valve diseases (with preserved LV ejection fraction).Finally, we showed that the ԑ–volume loop characteristics provide discriminative capacity compared with conventional measures of LV function. Abstract The purpose of this study was to examine left ventricular (LV) strain (ԑ)–volume loops to provide novel insight into the haemodynamic cardiac consequences of aortic valve stenosis (AS) and aortic valve regurgitation (AR). Twenty‐seven participants were retrospectively recruited: AR (n = 7), AS (n = 10) and control subjects (n = 10). Standard transthoracic echocardiography was used to obtain apical four‐chamber images to construct ԑ–volume relationships, which were assessed using the following parameters: early systolic ԑ (ԑ_ES); slope of ԑ–volume relationship during systole (Sslope); end‐systolic peak ԑ (peak ԑ); and diastolic uncoupling (systolic ԑ–diastolic ԑ at same volume) during early diastole (UNCOUP_ED) and late diastole (UNCOUP_LD). Receiver operating characteristic curves were used to determine the ability to detect impaired LV function. Although LV ejection fraction was comparable between groups, longitudinal peak ԑ was reduced compared with control subjects

  20. Exploratory assessment of left ventricular strain-volume loops in severe aortic valve diseases.

    Science.gov (United States)

    Hulshof, Hugo G; van Dijk, Arie P; George, Keith P; Hopman, Maria T E; Thijssen, Dick H J; Oxborough, David L

    2017-06-15

    Severe aortic valve diseases are common cardiac abnormalities that are associated with poor long-term survival. Before any reduction in left ventricular (LV) function, the left ventricle undergoes structural remodelling under the influence of changing haemodynamic conditions. In this study, we combined temporal changes in LV structure (volume) with alterations in LV functional characteristics (strain, ԑ) into a ԑ-volume loop, in order to provide novel insight into the haemodynamic cardiac consequences of aortic valve diseases in those with preserved LV ejection fraction. We showed that our novel ԑ-volume loop and the specific loop characteristics provide additional insight into the functional and mechanical haemodynamic consequences of severe aortic valve diseases (with preserved LV ejection fraction). Finally, we showed that the ԑ-volume loop characteristics provide discriminative capacity compared with conventional measures of LV function. The purpose of this study was to examine left ventricular (LV) strain (ԑ)-volume loops to provide novel insight into the haemodynamic cardiac consequences of aortic valve stenosis (AS) and aortic valve regurgitation (AR). Twenty-seven participants were retrospectively recruited: AR (n = 7), AS (n = 10) and control subjects (n = 10). Standard transthoracic echocardiography was used to obtain apical four-chamber images to construct ԑ-volume relationships, which were assessed using the following parameters: early systolic ԑ (ԑ_ES); slope of ԑ-volume relationship during systole (Sslope); end-systolic peak ԑ (peak ԑ); and diastolic uncoupling (systolic ԑ-diastolic ԑ at same volume) during early diastole (UNCOUP_ED) and late diastole (UNCOUP_LD). Receiver operating characteristic curves were used to determine the ability to detect impaired LV function. Although LV ejection fraction was comparable between groups, longitudinal peak ԑ was reduced compared with control subjects. In contrast, ԑ_ES and Sslope were

  1. Diagnostic electrocardiographic dyad criteria of emphysema in left ventricular hypertrophy.

    Science.gov (United States)

    Lanjewar, Swapnil S; Chhabra, Lovely; Chaubey, Vinod K; Joshi, Saurabh; Kulkarni, Ganesh; Kothagundla, Chandrasekhar; Kaul, Sudesh; Spodick, David H

    2013-01-01

    The electrocardiographic diagnostic dyad of emphysema, namely a combination of the frontal vertical P-vector and a narrow QRS duration, can serve as a quasidiagnostic marker for emphysema, with specificity close to 100%. We postulated that the presence of left ventricular hypertrophy in emphysema may affect the sensitivity of this electrocardiographic criterion given that left ventricular hypertrophy generates prominent left ventricular forces and may increase the QRS duration. We reviewed the electrocardiograms and echocardiograms for 73 patients with emphysema. The patients were divided into two groups based on the presence or absence of echocardiographic evidence of left ventricular hypertrophy. The P-vector, QRS duration, and forced expiratory volume in one second (FEV1) were computed and compared between the two subgroups. There was no statistically significant difference in qualitative lung function (FEV1) between the subgroups. There was no statistically significant difference in mean P-vector between the subgroups. The mean QRS duration was significantly longer in patients with left ventricular hypertrophy as compared with those without left ventricular hypertrophy. The presence of left ventricular hypertrophy may not affect the sensitivity of the P-vector verticalization when used as a lone criterion for diagnosing emphysema. However, the presence of left ventricular hypertrophy may significantly reduce the sensitivity of the electrocardiographic diagnostic dyad in emphysema, as it causes a widening of the QRS duration.

  2. Left ventricular volume during supine exercise: importance of myocardial scar in patients with coronary heart disease

    International Nuclear Information System (INIS)

    Mann, D.L.; Scharf, J.; Ahnve, S.; Gilpin, E.

    1987-01-01

    Existing studies suggest that exercise-induced ischemia produces an increase in left ventricular end-diastolic volume; however, all of these studies have included patients with previous myocardial infarction. To test whether the end-diastolic volume response to exercise is related to the extent of myocardial scar, the results of gated radionuclide supine exercise tests performed on 130 subjects were reviewed. The patient group comprised 130 subjects were reviewed. The patient group comprised 130 men aged 35 to 65 years (mean +/- SD 52 +/- 5) with documented coronary heart disease. The extent of myocardial ischemia and scar formation was assessed by stress electrocardiography and thallium-201 scintigraphy. Patients were classified into three groups on the basis of left ventricular end-diastolic volume response at peak exercise: group 1 (n = 72) had an increase of end-diastolic volume greater than 10%, group 2 (n = 41) had a change in end-diastolic volume less than 10% and group 3 (n = 17) had a decrease in end-diastolic volume greater than 10% (n = 17). At rest there was no significant difference among groups in heart rate, systolic blood pressure, end-diastolic (EDVrest) or end-systolic volumes or ejection fraction (p greater than 0.05); however, at peak exercise the end-systolic volume response was significantly greater for group 1 (p less than 0.002)

  3. Evaluation of left ventricular function using digital subtraction ventriculography

    International Nuclear Information System (INIS)

    Yiannikas, J.; Detrano, R.

    1986-01-01

    Digital subtraction ventriculography following injections of contrast via peripheral veins provides excellent images to assess left ventricular function. The images are essentially identical to those following DCV, but allow more uniform mixing of contrast in the left ventricular chamber. Furthermore, few, if any, cardiac arrhythmias occur, hence obviating difficulties that arise from DCV. The spatial resolution of the method is such that regional wall motion assessment of ventricular function is more accurate than that of other noninvasive imaging methods. The use of video-densitometry allows accurate assessment of left ventricular function even when the left ventricular cavity is nonsymmetrically deformed and aneurysmal. In the setting of the cardiac catheterization laboratory, digital ventriculography may provide a safer means of assessing left ventricular function when critical coronary or myocardial disease is present and allows multiple assessments of ventricular function during the same study. Although excellent correlations with standard ventriculography have been noted by all workers, significant discrepancies still exist in individual patients, particularly in the calculations of end diastolic volumes. In the authors experience and in those of most workers, the largest discrepancies existed in patients in whom suboptimal studies are included for analysis. The most frequent reason for the occasional suboptimal study as with all digital subtraction work is the misregistration that results from motion

  4. Effect of fluid loading on left ventricular volume and stroke volume variability in patients with end-stage renal disease: a pilot study

    Science.gov (United States)

    Kanda, Hirotsugu; Hirasaki, Yuji; Iida, Takafumi; Kanao-Kanda, Megumi; Toyama, Yuki; Kunisawa, Takayuki; Iwasaki, Hiroshi

    2015-01-01

    Purpose The aim of this study was to investigate fluid loading-induced changes in left ventricular end-diastolic volume (LVEDV) and stroke volume variability (SVV) in patients with end-stage renal disease (ESRD) using real-time three-dimensional transesophageal echocardiography and the Vigileo-FloTrac system. Patients and methods After obtaining ethics committee approval and informed consent, 28 patients undergoing peripheral vascular procedures were studied. Fourteen patients with ESRD on hemodialysis (HD) were assigned to the HD group and 14 patients without ESRD were assigned to the control group. Institutional standardized general anesthesia was provided in both groups. SVV was measured using the Vigileo-FloTrac system. Simultaneously, a full-volume three-dimensional transesophageal echocardiography dataset was acquired to measure LVEDV, left ventricular end-systolic volume, and left ventricular ejection fraction. Measurements were obtained before and after loading 500 mL hydroxyethyl starch over 30 minutes in both groups. Results In the control group, intravenous colloid infusion was associated with a significant decrease in SVV (13.8%±2.6% to 6.5%±2.6%, P<0.001) and a significant increase in LVEDV (83.6±23.4 mL to 96.1±28.8 mL, P<0.001). While SVV significantly decreased after infusion in the HD group (16.2%±6.0% to 6.2%±2.8%, P<0.001), there was no significant change in LVEDV. Conclusion Our preliminary data suggest that fluid responsiveness can be assessed not by LVEDV but also by SVV due to underlying cardiovascular pathophysiology in patients with ESRD. PMID:26527879

  5. Beat-to-beat left ventricular performance in atrial fibrillation: radionuclide assessment with the computerized nuclear probe

    International Nuclear Information System (INIS)

    Schneider, J.; Berger, H.J.; Sands, M.J.; Lachman, A.B.; Zaret, B.L.

    1983-01-01

    There is wide beat-to-beat variability in cycle length and left ventricular performance in patients with atrial fibrillation. In this study, left ventricular ejection fraction and relative left ventricular volumes were evaluated on a beat-to-beat basis with the computerized nuclear probe, an instrument with sufficiently high sensitivity to allow continuous evaluation of the radionuclide time-activity curve. Of 18 patients with atrial fibrillation, 5 had mitral stenosis, 6 had mitral regurgitation, and 7 had coronary artery disease. Fifty consecutive beats were analyzed in each patient. The mean left ventricular ejection fraction ranged from 17 to 51%. There was substantial beat-to-beat variation in cycle length and left ventricular ejection fraction in all patients, including those with marked left ventricular dysfunction. In 14 patients who also underwent multiple gated cardiac blood pool imaging, there was an excellent correlation between mean ejection fraction derived from the nuclear probe and gated ejection fraction obtained by gamma camera imaging (r . 0.90). Based on beat-to-beat analysis, left ventricular function was dependent on relative end-diastolic volume and multiple preceding cycle lengths, but not preceding end-systolic volumes. This study demonstrates that a single value for left ventricular ejection fraction does not adequately characterize left ventricular function in patients with atrial fibrillation. Furthermore, both the mean beat-to-beat and the gated ejection fraction may underestimate left ventricular performance at rest in such patients

  6. Assessment of left ventricular function by thallium-201 quantitative gated cardiac SPECT

    International Nuclear Information System (INIS)

    Baba, Akira; Hano, Takuzo; Ohmori, Hisashi; Ibata, Masayo; Kawabe, Tetsuya; Kubo, Takashi; Kimura, Keizo; Nishio, Ichiro

    2002-01-01

    Present study was designed to evaluate the accuracy of the measurement of left ventricular volume by quantitative gated SPECT (QGS) software using 201 Tl and the effect of cutoff frequency of Butterworth prereconstruction filter on the calculation of volume. The RH-2 type cardiac phantom and 20 patients with ischemic heart disease were studied. Left ventricular end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were calculated by the QGS software using the various frequency of Butterworth filter. These parameters were evaluated by Simpson's method using left ventriculography (LVG). The volume of the phantom calculated by QGS was under-estimated by 14%. In the clinical study, EDV and ESV measured by QGS were smaller than those obtained from LVG by 10%. When the cutoff frequency of Butterworth filter was 0.43 cycles/cm, the values measured by QGS were best correlated with those by LVG (EDV: r=0.80, p 201 Tl quantitative gated cardiac SPECT can estimate myocardial ischemia and left ventricular function simultaneously. (author)

  7. Clinical usefulness of cine MRI for evaluation of left ventricular volume and diagnosis of heart and great vessel diseases

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, Takeshi; Anno, Hirofumi; Uritani, Tomizo [Fujita-Gakuen Health Univ., Toyoake, Aichi (Japan); and others

    1990-01-01

    ECG-gated cine mode magnetic resonance (MR) imaging was performed in 20 patients with various heart deseases. Left ventricular volume (LVV) and left ventricular ejection fraction (LVEF) were calculated on MR images obtained in left ventricular vertical and horizontal long axis views. The findings were compared with those obtained from left ventriculography. There was a significant positive correlation between MR imaging and ventriculography for both LVV and LVEF (p<0.001). In Marfan syndrome after surgery for dissecting aneurysm of the aorta, MR imaging was capable of visualizing not only the whole aorta in a single plane but also enlargement of the aortic root. It also depicted asynergy and thinned wall of the infarcted myocardium for myocardial infarction; an enlarged left auricle, the thickened septum, and constricted outflow tract for idiopathic hypertrophic subaortic stenosis; shunt flow for ventricular septum defect; and an enlarged aortic root for aortitis syndrome. Using ventriculography as the standard, cine MR imaging was frequently false positive for the detection of mitral regurgitation. There was, however, good concordance between MR imaging and ventriculography in detecting aortic regurgitation. In addition, MR imaging was equivalent to color Doppler technique for detecting valvular regurgitation. (N.K.).

  8. Clinical usefulness of cine MRI for evaluation of left ventricular volume and diagnosis of heart and great vessel diseases

    International Nuclear Information System (INIS)

    Kondo, Takeshi; Anno, Hirofumi; Uritani, Tomizo

    1990-01-01

    ECG-gated cine mode magnetic resonance (MR) imaging was performed in 20 patients with various heart deseases. Left ventricular volume (LVV) and left ventricular ejection fraction (LVEF) were calculated on MR images obtained in left ventricular vertical and horizontal long axis views. The findings were compared with those obtained from left ventriculography. There was a significant positive correlation between MR imaging and ventriculography for both LVV and LVEF (p<0.001). In Marfan syndrome after surgery for dissecting aneurysm of the aorta, MR imaging was capable of visualizing not only the whole aorta in a single plane but also enlargement of the aortic root. It also depicted asynergy and thinned wall of the infarcted myocardium for myocardial infarction; an enlarged left auricle, the thickened septum, and constricted outflow tract for idiopathic hypertrophic subaortic stenosis; shunt flow for ventricular septum defect; and an enlarged aortic root for aortitis syndrome. Using ventriculography as the standard, cine MR imaging was frequently false positive for the detection of mitral regurgitation. There was, however, good concordance between MR imaging and ventriculography in detecting aortic regurgitation. In addition, MR imaging was equivalent to color Doppler technique for detecting valvular regurgitation. (N.K.)

  9. Evaluation of left ventricular volume by MRI using modified Simpson's rule method

    International Nuclear Information System (INIS)

    Okamura, Masahiro; Kondo, Takeshi; Anno, Naoko

    1990-01-01

    The conventional contrast left ventriculogrpahy (LVG) has been the gold standard for estimating left ventricular volume (LVV), but it is an invasive technique, and volume overload must be caused by contrast medium. the true left ventricular (LV) long axis may not be obtained by LVG in routine right anterior oblique (RAO) projection. MRI, on the other hand, is noninvasive, does not require contrast medium, and permits to obtain the true LV long axis sections. Thus, MRI seems the ideal technique for estimating LVV. To estimate LVV, we have developed the on-line programs for calculating LVV by single-plane (SMS) or biplane modified Simpson's rule method (BMS), and have applied these programs to the water in the bottle with the elliptic short axis plane, normal volunteer and patients with various heart diseases. In the water phantom, the water volume calculated by the BMS was more accurate than the SMS. In nine normal volunteers, multiple LV short axis sections in each end-systole and end-diastole were obtained by ECG-gated spin echo MRI, LVV as standard was calculated by true Simpson's rule method (TS) on these images. Then both vertical and horizontal LV long axis sections were also obtained by ECG-gated field echo (FE) rephasing cine MRI, LVV was calculated by the BMS or SMS on these images. The BMS or SMS significantly correlated (r=0.974, r=0.927, 0.947) with TS for estimating LVV, respectively. In 20 patients with various heart diseases, both vertical and horizontal LV long axis sections were obtained by FE cine MRI. LVV (r=0.907 and r=0.901) and EF (r=0.822 and r=0.938) calculated by the SMS on the vertical or horizontal LV long axis sections significantly correlated with the conventional RAO-LVG, respectively. In conclusion, the MRI using our on-line programs would be clinically useful for estimating LVV and EF. (author)

  10. Evaluation of left ventricular function in maintained hemodialysis patients using real-time three-dimensional echocardiography

    International Nuclear Information System (INIS)

    Wang Ling; Wang Jing; Zheng Min; Zhang Chunmei; Li Chan

    2010-01-01

    Objective: Using magnetic resonance imaging (MRI) technique as control standard, to explore the feasibility and accuracy of true real-time three-dimensional volume quantitative techniques (RT-3DE) in evaluation of the left ventricular volume (LVV) and left ventricular ejection fraction (LVEF) of the maintained hemodialysis (MHD) patients. Methods: 48 MHD patients were enrolled in this study. RT-3DE was used to detect the LVV and LVEF, while Simpson's method and M-Teichholz method were used at the same time. The results of the three methods were compared with the data measured by MRI. Results: (1)The data measured by RT-3DE method showed a highly positive correlation with the LVV detected by MRI (r=0.90, P 0.05). (2)When heart cavity deformed, the results of left ventricular end-diastolic volume (LVEDV) and left ventricular end-systolic volume (LVESV) measured by M-Teichholz method and Simpson's method were higher or lower than the data measured by RT-3DE method, and the differences were statistically significant (all P<0.05). Conclusion: RT-3DE can accurately measure the volume of normal cardiac chambers and the left ventricular cavity deformation volume. The result of RT-3DE has higher accuracy compared with Simpson's method and M-Teichholz method. (authors)

  11. Value of the regurgitant volume to end diastolic volume ratio to predict the regression of left ventricular dimensions after valve replacement in aortic insufficiency

    NARCIS (Netherlands)

    P.M. Fioretti (Paolo); C. Tirtaman; E. Bos (Egbert); P.W.J.C. Serruys (Patrick); J.R.T.C. Roelandt (Jos)

    1987-01-01

    textabstractThe aim of this study was to assess the value of regurgitant stroke volume (RSV) to end-diastolic volume (EDV) ratio to predict the regression of left ventricular (LV) dimensions after uncomplicated valve replacement in 34 patients with severe pure aortic insufficiency. The RSV/EDV ratio

  12. Allowable variance set on left ventricular function parameter

    International Nuclear Information System (INIS)

    Zhou Li'na; Qi Zhongzhi; Zeng Yu; Ou Xiaohong; Li Lin

    2010-01-01

    Purpose: To evaluate the influence of allowable Variance settings on left ventricular function parameter of the arrhythmia patients during gated myocardial perfusion imaging. Method: 42 patients with evident arrhythmia underwent myocardial perfusion SPECT, 3 different allowable variance with 20%, 60%, 100% would be set before acquisition for every patients,and they will be acquired simultaneously. After reconstruction by Astonish, end-diastole volume(EDV) and end-systolic volume (ESV) and left ventricular ejection fraction (LVEF) would be computed with Quantitative Gated SPECT(QGS). Using SPSS software EDV, ESV, EF values of analysis of variance. Result: there is no statistical difference between three groups. Conclusion: arrhythmia patients undergo Gated myocardial perfusion imaging, Allowable Variance settings on EDV, ESV, EF value does not have a statistical meaning. (authors)

  13. Differing responses in right and left ventricular filling, loading and volumes during positive end-expiratory pressure

    International Nuclear Information System (INIS)

    Schulman, D.S.; Biondi, J.W.; Matthay, R.A.; Zaret, B.L.; Soufer, R.

    1989-01-01

    Using a combined hemodynamic and radionuclide technique, 20 patients with varied ventricular function were evaluated during positive end-expiratory pressure (PEEP) application. Left ventricular (LV) and right ventricular (RV) ejection fractions and cardiac output were measured, and ventricular volumes were derived. Seven patients (group 1) who had an increase in LV end-diastolic volume with PEEP and 13 patients (group 2) who had the more typical response, a decrease in LV end-diastolic volume with PEEP, were identified. Compared with group 2, group 1 patients had a higher incidence of coronary artery disease (5 of 7 vs 1 of 13, p less than 0.005) and lower cardiac output (3.9 +/- 1.6 vs 9.1 +/- 3.2 liters/min, p less than 0.005), LV ejection fraction (27 +/- 13 vs 51 +/- 21%, p less than 0.05), RV ejection fraction (15 +/- 6 vs 32 +/- 8%, p less than 0.005) and peak filling rate (1.32 +/- 0.43 vs 3.51 +/- 1.70 end-diastolic volumes/s, p less than 0.05). LV and RV volumes increased and peak filling rate decreased with PEEP in group 1, whereas in group 2 LV volume decreased and RV volume and peak filling rate remained unchanged. Using stepwise regression analysis, the change in LV volume with PEEP was related directly to baseline systemic vascular resistance and inversely to baseline blood pressure. Similarly, the change in peak filling rate with PEEP was inversely related to the change in RV end-diastolic volume. Thus, the hemodynamic response to PEEP is heterogeneous and may be related to LV ischemia

  14. Assessment of left ventricular function by thallium-201 quantitative gated cardiac SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Baba, Akira; Hano, Takuzo; Ohmori, Hisashi; Ibata, Masayo; Kawabe, Tetsuya; Kubo, Takashi; Kimura, Keizo; Nishio, Ichiro [Wakayama Medical Coll. (Japan)

    2002-02-01

    Present study was designed to evaluate the accuracy of the measurement of left ventricular volume by quantitative gated SPECT (QGS) software using {sup 201}Tl and the effect of cutoff frequency of Butterworth prereconstruction filter on the calculation of volume. The RH-2 type cardiac phantom and 20 patients with ischemic heart disease were studied. Left ventricular end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were calculated by the QGS software using the various frequency of Butterworth filter. These parameters were evaluated by Simpson's method using left ventriculography (LVG). The volume of the phantom calculated by QGS was under-estimated by 14%. In the clinical study, EDV and ESV measured by QGS were smaller than those obtained from LVG by 10%. When the cutoff frequency of Butterworth filter was 0.43 cycles/cm, the values measured by QGS were best correlated with those by LVG (EDV: r=0.80, p<0.001; ESV: r=0.86, p<0.001; EF: r=0.80, p<0.001). These data suggest that {sup 201}Tl quantitative gated cardiac SPECT can estimate myocardial ischemia and left ventricular function simultaneously. (author)

  15. Use of gated N-13-NH3 micro-PET to examine left ventricular function in rats

    NARCIS (Netherlands)

    Szymanski, Mariusz K.; Kruizinga, Silvana; Tio, Rene A.; Willemsen, Antoon T. M.; Schaefers, Michael A.; Stegger, Lars; Dierckx, Rudi A.; Hillege, Hans L.; Slart, Riemer H. J. A.

    Introduction: Myocardial perfusion gating techniques offer the possibility of measurement of left ventricular end-systolic (ESV) and end-diastolic volume (EDV) and left ventricular ejection fraction (LVEF) in clinical and preclinical trials. The aim of this study was to evaluate left ventricular

  16. Evaluation of global and regional left ventricular function obtained by quantitative gated SPECT using {sup 99m}Tc-tetrofosmin for left ventricular dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Ban, Kazunobu; Nakajima, Tohru; Iseki, Harukazu; Abe, Sumihisa; Handa, Shunnosuke; Suzuki, Yutaka [Tokai Univ., Isehara, Kanagawa (Japan). School of Medicine

    2000-08-01

    The quantitative gated SPECT (QGS) software is able to calculate LV volumes and visualize LV wall motion and perfusion throughout the cardiac cycle using an automatic edge detection algorithm of the left ventricle. We evaluated the reliability of global and regional LV function assessment derived from QGS by comparing it with the results from left ventriculo-cineangiography (LVG). In 20 patients with left ventricular dysfunction who underwent ECG gated {sup 99m}Tc-tetrofosmin SPECT, the end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (LVEF) were calculated. The QGS-assessed regional wall motion was determined using the cinematic display. QGS-derived EDV, ESV and LVEF correlated well with those by LVG (p<0.001 for each). There was a good correlation between wall motion score (WMS) derived from the QGS and the LVG (r=0.40, p<0.05). In some patients with extensive myocardial infarction, there was a discrepancy in the regional wall motion results between QGS and LVG. The ECG-gated SPECT using QGS is useful to evaluate global and regional LV functions in left ventricular dysfunction. (author)

  17. Diagnostic electrocardiographic dyad criteria of emphysema in left ventricular hypertrophy

    Directory of Open Access Journals (Sweden)

    Lanjewar SS

    2013-11-01

    Full Text Available Swapnil S Lanjewar,1 Lovely Chhabra,1 Vinod K Chaubey,1 Saurabh Joshi,1 Ganesh Kulkarni,1 Chandrasekhar Kothagundla,1 Sudesh Kaul,1 David H Spodick21Department of Internal Medicine, 2Department of Cardiovascular Medicine, Saint Vincent Hospital, University of Massachusetts Medical School, Worcester, MA, USABackground: The electrocardiographic diagnostic dyad of emphysema, namely a combination of the frontal vertical P-vector and a narrow QRS duration, can serve as a quasidiagnostic marker for emphysema, with specificity close to 100%. We postulated that the presence of left ventricular hypertrophy in emphysema may affect the sensitivity of this electrocardiographic criterion given that left ventricular hypertrophy generates prominent left ventricular forces and may increase the QRS duration.Methods: We reviewed the electrocardiograms and echocardiograms for 73 patients with emphysema. The patients were divided into two groups based on the presence or absence of echocardiographic evidence of left ventricular hypertrophy. The P-vector, QRS duration, and forced expiratory volume in one second (FEV1 were computed and compared between the two subgroups.Results: There was no statistically significant difference in qualitative lung function (FEV1 between the subgroups. There was no statistically significant difference in mean P-vector between the subgroups. The mean QRS duration was significantly longer in patients with left ventricular hypertrophy as compared with those without left ventricular hypertrophy.Conclusion: The presence of left ventricular hypertrophy may not affect the sensitivity of the P-vector verticalization when used as a lone criterion for diagnosing emphysema. However, the presence of left ventricular hypertrophy may significantly reduce the sensitivity of the electrocardiographic diagnostic dyad in emphysema, as it causes a widening of the QRS duration.Keywords: emphysema, electrocardiogram, left ventricular hypertrophy, chronic

  18. Hemodynamic and radionuclide effects of acute captopril therapy for heart failure: changes in left and right ventricular volumes and function at rest and during exercise

    International Nuclear Information System (INIS)

    Massie, B.; Kramer, B.L.; Topic, N.; Henderson, S.G.

    1982-01-01

    Although the resting hemodynamic effects of captopril in congestive heart failure are known, little information is available about the hemodynamic response to captopril during exercise or about changes in noninvasive measurements of the size and function of both ventricles. In this study, 14 stable New York Heart Association class III patients were given 25 mg of oral captopril. Rest and exercise hemodynamic measurements and blood pool scintigrams were performed simultaneously before and 90 minutes after captopril. The radionuclide studies were analyzed for left and right ventricular end-diastolic volumes, end-systolic volumes, ejection fractions and pulmonary blood volume. The primary beneficial responses at rest were decreases in left and right ventricular end-diastolic volumes from 388 +/- 81 to 350 +/- 77 ml and from 52 +/- 26 to 43 +/- 20 volume units, respectively, and in their corresponding filling pressures, from 24 +/- 10 to 17 +/- 9 mm Hg and 10 +/- 5 to 6 +/- 5 mm Hg. Although stroke volume did not increase significantly, both left and right ventricular ejection fractions increased slightly, from 19 +/- 6% to 22+/- 5% and from 25 +/- 9% to 29 +/- 11%, respectively. During exercise, similar changes were noted in both hemodynamic and radionuclide indexes. This, in patients with moderate symptomatic limitation from chronic heart failure, captopril predominantly reduces ventricular volume and filling pressure, with a less significant effect on cardiac output. These effects persist during exercise, when systemic vascular resistance is already very low. Radionuclide techniques are valuable in assessing the drug effect in these subjects, particularly when ventricular volumes are also measured

  19. Assessment of left ventricular function and volumes by myocardial perfusion scintigraphy - comparison of two algorithms

    International Nuclear Information System (INIS)

    Zajic, T.; Fischer, R.; Brink, I.; Moser, E.; Krause, T.; Saurbier, B.

    2001-01-01

    Aim: Left ventricular volume and function can be computed from gated SPECT myocardial perfusion imaging using emory cardiac toolbox (ECT) or gated SPECT quantification (GS-Quant). The aim of this study was to compare both programs with respect to their practical application, stability and precision on heart-models as well as in clinical use. Methods: The volumes of five cardiac models were calculated by ECT and GS-Quant. 48 patients (13 female, 35 male) underwent a one day stress-rest protocol and gated SPECT. From these 96 gated SPECT images, left ventricular ejection fraction (LVEF), end-diastolic volume (EDV) and end-systolic volume (ESV) were estimated by ECT and GS-Quant. For 42 patients LVEF was also determined by echocardiography. Results: For the cardiac models the computed volumes showed high correlation with the model-volumes as well as high correlation between ECT and GS-Quant (r ≥0.99). Both programs underestimated the volume by approximately 20-30% independent of the ventricle-size. Calculating LVEF, EDV and ESV, GS-Quant and ECT correlated well to each other and to the LVEF estimated by echocardiography (r ≥0.86). LVEF values determined with ECT were about 10% higher than values determined with GS-Quant or echocardiography. The incorrect surfaces calculated by the automatic algorithm of GS-Quant for three examinations could not be corrected manually. 34 of the ECT studies were optimized by the operator. Conclusion: GS-Quant and ECT are two reliable programs in estimating LVEF. Both seem to underestimate the cardiac volume. In practical application GS-Quant was faster and easier to use. ECT allows the user to define the contour of the ventricle and thus is less susceptible to artifacts. (orig.) [de

  20. Significant correlation of P-wave parameters with left atrial volume index and left ventricular diastolic function.

    Science.gov (United States)

    Tsai, Wei-Chung; Lee, Kun-Tai; Wu, Ming-Tsang; Chu, Chih-Sheng; Lin, Tsung-Hsien; Hsu, Po-Chao; Su, Ho-Ming; Voon, Wen-Chol; Lai, Wen-Ter; Sheu, Sheng-Hsiung

    2013-07-01

    The 12-lead electrocardiogram (ECG) is a commonly used tool to access left atrial enlargement, which is a marker of left ventricular diastolic dysfunction (LVDD). The aim of this study was to evaluate any association of the P-wave measurements in ECG with left atrial volume (LAV) index and LVDD. This study enrolled 270 patients. In this study, 4 ECG P-wave parameters corrected by heart rate, that is, corrected P-wave maximum duration (PWdurMaxC), corrected P-wave dispersion (PWdisperC), corrected P-wave area (PWareaC) and corrected mean P-wave duration (meanPWdurC), were measured. LAV and left ventricular diastolic parameters were measured from echocardiography. LVDD was defined as a pseudonormal or restrictive mitral inflow pattern. The 4 P-wave parameters were significantly correlated with the LAV index after adjusting for age, sex, diabetes, hypertension, coronary artery disease, body mass index and diastolic blood pressure in multivariate analysis. The standardized β coefficients of PWdurMaxC, PWdisperC, meanPWdurC and PWareaC were 0.338, 0.298, 0.215 and 0.296, respectively. The 4 P-wave parameters were also significantly correlated with LVDD after multivariate logistic regression analysis. The odds ratios (95% confidence intervals) of PWdurMaxC, PWdisperC, meanPWdurC and PWareaC were 1.03 (1.01-1.04), 1.02 (1.04-1.04), 1.04 (1.02-1.07) and 1.01 (1.00-1.02), respectively. This study demonstrated that PWdurMaxC, PWdisperC, meanPWdurC and PWareaC were important determinants of the LAV index and LVDD. Therefore, screening patients by means of the 12-lead ECG may be helpful in identifying a high-risk group of increased LAV index and LVDD.

  1. Usefulness of left ventricular wall thickness-to-diameter ratio in thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Manno, B.; Hakki, A.H.; Kane, S.A.; Iskandrian, A.S.

    1983-01-01

    The ratio of left ventricular wall thickness to the cavity dimension, as seen on thallium-201 images, was used in this study to predict left ventricular ejection fraction and volume. We obtained rest thallium-201 images in 50 patients with symptomatic coronary artery disease. The thickness of a normal-appearing segment of the left ventricular wall and the transverse diameter of the cavity were measured in the left anterior oblique projection. The left ventricular ejection fraction and volume in these patients were determined by radionuclide ventriculography. There was a good correlation between thickness-to-diameter ratio and ejection fraction and end-systolic volume. In 18 patients with a thickness-to-diameter ratio less than 0.70, the ejection fraction was lower than in the 16 patients with thickness-to-diameter ratio greater than or equal to 1.0. Similarly, in patients with a thickness-to-diameter ratio less than 0.70, the end-diastolic and end-systolic volume were higher than in the remaining patients with higher thickness-to-diameter ratios. All 18 patients with a thickness-to-diameter ratio less than 0.70 had ejection fractions less than 40%; 14 of 15 patients with a thickness-to-diameter ratio greater than or equal to 1.0 had an ejection fraction greater than 40%. The remaining 16 patients with a thickness-to-diameter ratio of 0.7-0.99 had intermediate ejection fractions and volumes.(ABSTRACT TRUNCATED AT 250 WORDS)

  2. Estudo da função ventricular na técnica de plicatura da parede livre do ventrículo esquerdo em cães Left ventricular function after plication of the left ventricular free wall in dogs

    Directory of Open Access Journals (Sweden)

    James Newton Bizetto Meira de Andrade

    2004-06-01

    Full Text Available OBJETIVO: Avaliar os efeitos da técnica na função ventricular esquerda em cães hígidos e com cardiomiopatia dilatada induzida pela doxorrubicina. MÉTODO: De 13 cães, oito receberam doxorrubicina até que a fração de encurtamento (FE fosse menor que 20%. Destes, quatro animais e os cinco não induzidos foram submetidos à plicatura da parede livre do ventrículo esquerdo (PPLVE. Os demais cães não foram operados. Foram avaliados débito cardíaco (DC, pressão arterial, exame físico, eletrocardiografia, sistema "Holter" e ecocardiografia, por 180 dias. RESULTADOS: Houve redução do volume ventricular esquerdo. Os cães induzidos melhoraram após a operação e a fração de ejeção (FEj retornou aos valores normais para a espécie. O DC e a FE aumentaram após a operação. Um cão foi a óbito. Nos cães não operados, a FE diminuiu e foram a óbito em torno de 40 dias após a indução; nos cães não induzidos, esta não se alterou. Houve extra-sístoles ventriculares, que se resolveram espontaneamente. CONCLUSÕES: A PPLVE sem circulação extracorpórea reduz o volume ventricular esquerdo e melhora a função cardíaca dos cães com cardiomiopatia dilatada induzida pela doxorrubicina, demonstrando baixa morbidade e mortalidade tardia.OBJECTIVE: We tested a new surgical technique, the plication of the left ventricular free wall, to reduce left ventricular area and volume and improve left ventricular systolic function, without using a cardiopulmonary bypass. METHODS: Dilated cardiomyopathy was induced in eight dogs by the injection of doxorubicin. Plication of the left ventricular free wall was performed in four dogs with induced cardiomyopathy and in five control dogs. Two dogs not submitted to surgery. The other two dogs died during the induction phase. Cardiac output, 2-dimensional and M-mode echocardiography, arterial blood pressure and electrocardiography were recorded over a 180 days period. Ambulatory electrocardiography

  3. Reduced left ventricular filling following blood volume extraction does not result in compensatory augmentation of cardiac mechanics.

    Science.gov (United States)

    Lord, Rachel; MacLeod, David; George, Keith; Oxborough, David; Shave, Rob; Stembridge, Mike

    2018-04-01

    What is the central question of this study? A reduction in left ventricular (LV) filling, and concomitant increase in heart rate, augments LV mechanics to maintain stroke volume (SV); however, the impact of reduced LV filling in isolation on SV and LV mechanics is currently unknown. What is the main finding and its importance? An isolated decrease in LV filling did not provoke a compensatory increase in mechanics to maintain SV; in contrast, LV mechanics and SV were reduced. These data indicate that when LV filling is reduced without changes in heart rate, LV mechanics do not compensate to maintain SV. An acute non-invasive reduction in preload has been shown to augment cardiac mechanics to maintain stroke volume and cardiac output. Such interventions induce concomitant changes in heart rate, whereas blood volume extraction reduces preload without changes in heart rate. Therefore, the purpose of this study was to determine whether a preload reduction in isolation resulted in augmented stroke volume achieved via enhanced cardiac mechanics. Nine healthy volunteers (four female, age 29 ± 11 years) underwent echocardiography for the assessment of left ventricular (LV) volumes and mechanics in a supine position at baseline and end extraction after the controlled removal of 25% of total blood volume (1062 ± 342 ml). Arterial blood pressure was monitored continuously by a pressure transducer attached to an indwelling radial artery catheter. Heart rate and total peripheral resistance were unchanged from baseline to end extraction, but systolic blood pressure was reduced (from 148 to 127 mmHg). From baseline to end extraction there were significant reductions in left ventricular end-diastolic volume (from 89 to 71 ml) and stroke volume (from 56 to 37 ml); however, there was no change in LV twist, basal or apical rotation. In contrast, LV longitudinal strain (from -20 to -17%) and basal circumferential strain (from -22 to -19%) were significantly reduced from

  4. Evaluation of left ventricular hypertrophy using thallium-201 myocardial scintigraphy, echocardiography and vectorcardiography

    International Nuclear Information System (INIS)

    Tsukahara, Yasunori; Owada, Kenji; Suzuki, Shigebumi

    1983-01-01

    Thallium-201 ( 201 Tl) myocardial scintigraphy was performed in 40 patients with left ventricular hypertrophy(LVH). Twelve out of 40 patients had pressure overloading (Aortic stenosis: 5, Hypertension: 7), 14 patients had volume overloading (Aortic regurgitation: 9, Mitral regurgitation: 5) and 14 had idiopathic cardiomyopathy (Hypertrophic type (HCM): 8, Congestive type (CCM): 6), respectively. LV area, LV uptake index and Wall uptake ratio were calculated from left anterior oblique view of 201 Tl myocardial images. These three indices of both pressure overloading and volume overloading were significantly higher than those of controls. The degree of LVH was indicated by both LV area and LV uptake index. LV area was significantly larger in volume overloading than in pressure overloading. In idiopathic cardiomyopathy, these three indices of HCM and LV area and LV uptake index of CCM were significantly increased compared with those of controls. LV area of CCM was significantly larger than that of HCM, while Wall uptake ratio of HCM was significantly higher than that of CCM. LV uptake index and Wall uptake ratio of HCM became higher according as left ventricular cavity became smaller. LV area of CCM became larger in proportion as left ventricular cavity became larger and as left ventricular wall thickness became thinner. (author)

  5. Value of radionuclide angiocardiography for determination of left ventricular volume in patients with valvular heart disease; Wartosc angiokardiografii radioizotopowej dla oznaczania objetosci lewej komory u chorych z zastawkowymi wadami serca

    Energy Technology Data Exchange (ETDEWEB)

    Konieczna, S.; Madeja, G.; Gosiewska-Marcinkowska, E.; Szumilak, B.; Brodzki, L.M.; Leszek, P. [Instytut Kardiologii, Warsaw (Poland)

    1992-12-31

    The aim of this study was to investigate usability of the Massardo method in calculating the left ventricular volume in patients with valvular defect. The group consisted of 21 patients with mitral defect. Left ventricular volumes obtained by contrast ventriculography were used for reference. The correlation coefficient between these two methods was 0.94, SEE=29 ml, V{sub nucl}=0.94 V{sub c.vent}+11. The end-systolic and end-diastolic outlines were marked manually. We concluded that the Massardo methods is an effective method of calculating the left ventricular volume also in group of patients with mitral defect. (author). 11 refs, 4 tabs.

  6. Quantitation of left ventricular dimensions and function by digital video subtraction angiography

    International Nuclear Information System (INIS)

    Higgins, C.B.; Norris, S.L.; Gerber, K.H.; Slutsky, R.A.; Ashburn, W.L.; Baily, N.

    1982-01-01

    Digital video subtraction angiography (DVSA) after central intravenous administration of contrast media was used in experimental animals and in patients with suspected coronary artery disease to quantitate left ventricular dimensions and regional and global contractile function. In animals, measurements of left ventricular (LV) volumes, wall thickness, ejection fraction, segmental contraction, and cardiac output correlated closely with sonocardiometry or thermodilution measurements. In patients, volumes and ejection fractions calculated from mask mode digital images correlated closely with direct left ventriculography. Global and segmental contractile function was displayed in patients by ejection shell images, stroke volume images, and time interval difference images. Central cardiovascular function was also quantitated by measurement of pulmonary transit time and calculation of pulmonary blood volume from digital fluoroscopic images. DVSA was shown to be useful and accurate in the quantitation of central cardiovascular physiology

  7. Longitudinal Assessment of Left Ventricular Mass in Autosomal Dominant Polycystic Kidney Disease

    Directory of Open Access Journals (Sweden)

    Taimur Dad

    2018-05-01

    Full Text Available Introduction: The high burden of cardiovascular morbidity and mortality in autosomal dominant polycystic kidney disease (ADPKD is related to development of hypertension and left ventricular hypertrophy. Blood pressure reduction has been shown to reduce left ventricular mass in ADPKD; however, moderators and predictors of response to lower blood pressure are unknown. Methods: This was a post hoc cohort analysis of HALT PKD study A, a randomized placebo controlled trial examining the effect of low blood pressure and single versus dual renin−angiotensin blockade in early ADPKD. Participants were hypertensive ADPKD patients 15 to 49 years of age with estimated glomerular filtration rate (eGFR > 60 ml/min per 1.73 m2 across 7 centers in the United States. Predictors included age, sex, baseline eGFR, systolic blood pressure, total kidney volume, serum potassium, and urine sodium, potassium, albumin, and aldosterone. Outcome was left ventricular mass index (LVMI measured using 1.5-T magnetic resonance imaging at months 0, 24, 48, and 60. Results: Reduction in LVMI was associated with higher baseline systolic blood pressure and larger kidney volume regardless of blood pressure control group assignment (P < 0.001 for both. Male sex and baseline eGFR were associated with a positive annual slope in LVMI (P < 0.001 and P = 0.07, respectively. Conclusion: Characteristics associated with higher risk of progression in ADPKD, including higher systolic blood pressure, larger kidney volume, and lower eGFR are associated with improvement in LVMI with intensive blood pressure control, whereas male sex is associated with a smaller slope of reduction in LVMI. Keywords: autosomal dominant polycystic kidney disease, hypertension, left ventricular hypertrophy, left ventricular mass index

  8. Comparison of left and right ventricular volume measurement using the Simpson's method and the area length method

    International Nuclear Information System (INIS)

    Hergan, Klaus; Schuster, Antonius; Fruehwald, Julia; Mair, Michael; Burger, Ralph; Toepker, Michael

    2008-01-01

    Purpose: To compare ventricular volume measurement using a volumetric approach in the three standard cardiac planes and ventricular volume estimation by a geometrical model, the Area-Length method (ALM). Materials and methods: Fifty-six healthy volunteers were examined (27 males, 29 females) on a 1.5 T MR-unit with ECG-triggered steady state free precision (SSFP) Cine-MR sequences and parallel image acquisition. Multiple slices in standardized planes including the short-axis view (sa), 4-chamber view (4ch), left and right 2-chamber views (2ch) were used to cover the whole heart. End-systolic and end-diastolic ventricular volumes (EDV, ESV), stroke volume (SV), and ejection fraction (EF) were calculated with Simpson's rule in all planes and with ALM in the 2ch and 4ch planes. Global function parameters measured in the sa plane were compared with those obtained in the other imaging planes. Results: A very good correlation is observed when comparing functional parameters calculated with Simpson's rule in all imaging planes: for instance, the mean EDV/ESV of the left and right ventricle of the female population group measured in sa, 4ch, and 2ch: left ventricle EDV/ESV 114.3/44.4, 120.9/46.5, and 117.7/45.3 ml; right ventricle EDV/ESV 106.6/46.0, 101.2/41.1, and 103.5/43.0 ml. Functional parameters of the left ventricle calculated with ALM in 2ch and 4ch correlate to parameters obtained in sa with Simpson's rule in the range of 5-10%: for instance, the EDV/ESV of the left ventricle of the male population group measured in the sa, 4ch, and 2ch: 160.3/63.5, 163.1/59.0, and 167.0/65.7 ml. Functional parameters of the right ventricle measured with ALM in 4ch are 40-50% lower and calculated in 2ch almost double as high as compared with the parameters obtained in sa with Simpson's rule: for instance, male right ventricular EDV/ESV measured in sa, 4ch, and 2ch: 153.4/68.1, 97.5/34.5, and 280.2/123.2 ml. The EF correlates for all imaging planes measured with the Simpson's rule

  9. CMR reference values for left ventricular volumes, mass, and ejection fraction using computer-aided analysis : The Framingham Heart Study

    NARCIS (Netherlands)

    Chuang, Michael L.; Gona, Philimon; Hautvast, Gilion L.T.F.; Salton, Carol J.; Breeuwer, Marcel; O'Donnell, Christopher J.; Manning, Warren J.

    Purpose To determine sex-specific reference values for left ventricular (LV) volumes, mass, and ejection fraction (EF) in healthy adults using computer-aided analysis and to examine the effect of age on LV parameters. Materials and Methods We examined data from 1494 members of the Framingham Heart

  10. Independent effects of both right and left ventricular function on plasma brain natriuretic peptide

    DEFF Research Database (Denmark)

    Vogelsang, Thomas Wiis; Jensen, Ruben J; Monrad, Astrid L

    2007-01-01

    BACKGROUND: Brain natriuretic peptide (BNP) is increased in heart failure; however, the relative contribution of the right and left ventricles is largely unknown. AIM: To investigate if right ventricular function has an independent influence on plasma BNP concentration. METHODS: Right (RVEF), left......, which is a strong prognostic marker in heart failure, independently depends on both left and right ventricular systolic function. This might, at least in part, explain why BNP holds stronger prognostic value than LVEF alone....... ventricular ejection fraction (LVEF), and left ventricular end-diastolic volume index (LVEDVI) were determined in 105 consecutive patients by first-pass radionuclide ventriculography (FP-RNV) and multiple ECG-gated equilibrium radionuclide ventriculography (ERNV), respectively. BNP was analyzed by immunoassay...

  11. Independent effects of both right and left ventricular function on plasma brain natriuretic peptide.

    Science.gov (United States)

    Vogelsang, Thomas Wiis; Jensen, Ruben J; Monrad, Astrid L; Russ, Kaspar; Olesen, Uffe H; Hesse, Birger; Kjaer, Andreas

    2007-09-01

    Brain natriuretic peptide (BNP) is increased in heart failure; however, the relative contribution of the right and left ventricles is largely unknown. To investigate if right ventricular function has an independent influence on plasma BNP concentration. Right (RVEF), left ventricular ejection fraction (LVEF), and left ventricular end-diastolic volume index (LVEDVI) were determined in 105 consecutive patients by first-pass radionuclide ventriculography (FP-RNV) and multiple ECG-gated equilibrium radionuclide ventriculography (ERNV), respectively. BNP was analyzed by immunoassay. Mean LVEF was 0.51 (range 0.10-0.83) with 36% having a reduced LVEF (left and right ventricular systolic function. This might, at least in part, explain why BNP holds stronger prognostic value than LVEF alone.

  12. Evaluation of left ventricular function by invasive and noninvasive methods

    Energy Technology Data Exchange (ETDEWEB)

    Kusukawa, R [Yamaguchi Univ., Ube (Japan). School of Medicine

    1982-06-01

    Noninvasive methods in cardiology have progressed very rapidly in recent years. Cardiac catheterization and angiocardiography are the standard methods for evaluating of cardiac performance, however, they need expensive apparatus and are time-consuming, arduous procedures which do not permit to repeat frequently, and sometimes risky. In this article, the indices of pump and muscle function of the heart obtained by invasive methods were compared to those indices obtained by noninvasive methods, and correlation between two groups and usefulness and limitation were discussed. Systolic time intervals are convenient and repeatable measures of left ventricular performance in clinical cardiology. There are significant correlations of PEP/LVET with stroke volume, ejection fraction and mean circumferential shortening velocity. Although some limitations are present in application of this method to certain diseases, these measures are useful in the evaluation of left ventricular performance. Echocardiography has made an era of the noninvasive cardiology. Left ventricular volume, ejection fraction, mean circumferential shortening velocity and PSP/ESVI are accurately calculated by echocardiographic measurement. Nuclear cardiology is also accurate noninvasive method in evaluation of cardiac performance. With this tremendous growth in this field, it will make next era of noninvasive cardiology.

  13. Value of radionuclide angiocardiography for determination of left ventricular volume in patients with valvular heart diseases (preliminary report)

    International Nuclear Information System (INIS)

    Madeja, G.; Konieczna, S.; Gosiewska-Marcinkowska, E.; Leszek, P.

    1991-01-01

    In 15 patients with mitral valve defect and 10 patients with aortic valve defect, left ventricular end-diastolic and end-systolic volumes were determined by gated radionuclide angiography. The results were compared with contrast ventriculography. The correlation coefficient between the two methods was much lower in cases of mitral valve diseases. (author). 1 tab

  14. Improved determination of left ventricular volume with myocardial tagging

    International Nuclear Information System (INIS)

    Peshock, R.M.; Takai, H.; Baker, K.V.; Clarke, G.D.; McDonald, G.G.; Parkey, R.W.

    1991-01-01

    Cine MR imaging can be used to determine ventricular volume and ejection fraction. However, definition of the endocardial surface can be difficult, leading some investigators to suggest that black-blood studies are preferable. Grid tagging with use of spatial modulation of magnetization has been used to improve assessments of wall motion. The purpose of this paper, is to determine if grid tagging would also facilitate definition of the endocardial border for volume and ejection fraction calculations. Grid tagging based on spatial modulation of magnetization was implemented on a Toshiba 0.5-T MR imaging device. Standard RAO images were obtained in 10 normal volunteers with use of standard cine MR imaging sequences (33/22) with and without grid tagging. Images were analyzed to determine ventricular volume, cardiac output and wall motion. Images obtained without tagging generally showed good contrast at end diastole, but definition of the endocardial border was frequently more difficult in middle to late systole. Images with tagging provided significantly better definition of endocardial borders, particularly during systole

  15. Detection of left ventricular thrombi by computerised tomography

    International Nuclear Information System (INIS)

    Nair, C.K.; Sketch, M.H.; Mahoney, P.D.; Lynch, J.D.; Mooss, A.N.; Kenney, N.P.

    1981-01-01

    Sixteen patients suspected of having left ventricular mural thrombi were studied. All had suffered transmural myocardial infarction. Fifteen patients had a ventricular aneurysm. One had had systemic emboli. The mean length of time between the myocardial infarction and the study was 14.8 months, with a range of one month to 79 months. All patients underwent computerised tomography of the heart, M-mode echocardiography (M-mode), and two-dimensional echocardiography (2-D). Eight patients underwent left ventricular cineangiography. Five patients had surgical confirmation. Computerised tomography, two-dimensional, and M-mode echocardiography predicted left ventricular mural thrombi in 10, eight, and one of the 16 patients, respectively. Left ventricular cineangiography predicted left ventricular mural thrombi in four out of eight patients. Computerised tomography and left ventricular cineangiography correctly predicted the presence or absence of left ventricular thrombi in all five patients who underwent operation. In the same group, however, two-dimensional and M-mode echocardiography failed to predict the presence of thrombi in one and three patients, respectively. Among the 11 patients without surgical confirmation, one, in whom no left ventricular thrombi were shown by M-mode and two-dimensional echocardiography, was found to have thrombi on computerised tomography. In another, two-dimensional echocardiography was positive but this finding was not confirmed either by computerised tomography or by left ventricular angiography. (author)

  16. Effects of a prostagrandin EP4-receptor agonist ONO-AE1-329 on the left ventricular pressure-volume relationship in the halothane-anesthetized dogs.

    Science.gov (United States)

    Honda, Atsushi; Nakamura, Yuji; Ohara, Hiroshi; Cao, Xin; Nomura, Hiroaki; Katagi, Jun; Wada, Takeshi; Izumi-Nakaseko, Hiroko; Ando, Kentaro; Sugiyama, Atsushi

    2016-03-15

    Cardiac effects of a prostagrandin EP4-receptor agonist ONO-AE1-329 were assessed in the halothane-anesthetized dogs under the monitoring of left ventricular pressure-volume relationship, which were compared with those of clinically recommended doses of dopamine, dobutamine and milrinone (n=4-5 for each treatment). ONO-AE1-329 was intravenously administered in doses of 0.3, 1 and 3 ng/kg/min for 10 min with a pause of 20 min. Dopamine in a dose of 3 µg/kg/min for 10 min, dobutamine in a dose of 1 µg/kg/min for 10 min and milrinone in a dose of 5 µg/kg/min for 10 min followed by 0.5 µg/kg/min for 10 min were intravenously administered. Low dose of ONO-AE1-329 increased the stroke volume. Middle dose of ONO-AE1-329 increased the cardiac output, left ventricular end-diastolic volume, ejection fraction, maximum upstroke/downstroke velocities of the left ventricular pressure and external work, but decreased the end-systolic pressure and internal work besides the change by the low dose. High dose of ONO-AE1-329 increased the heart rate and maximum elastance, but decreased the end-systolic volume besides the changes by the middle dose. Dopamine, dobutamine and milrinone exerted essentially similar cardiac effects to ONO-AE1-329, but they did not significantly change the end-diastolic volume, end-systolic volume, stroke volume, ejection fraction, end-systolic pressure, maximum elastance, external work or internal work. Thus, EP4-receptor stimulation by ONO-AE1-329 may have potential to better promote the passive ventricular filling than the conventional cardiotonic drugs, which could become a candidate of novel therapeutic strategy for the treatment of heart failure with preserved ejection fraction. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Left ventricular function in right ventricular overload

    International Nuclear Information System (INIS)

    Iwanaga, Shiro; Handa, Shunnosuke; Abe, Sumihisa; Onishi, Shohei; Nakamura, Yoshiro; Kunieda, Etsuo; Ogawa, Koichi; Kubo, Atsushi

    1989-01-01

    This study clarified regional and global functions of the distorted left ventricle due to right ventricular overload by gated radionuclide ventriculography (RNV). Cardiac catheterization and RNV were performed in 13 cases of atrial septal defect (ASD), 13 of pure mitral stenosis (MS), 10 of primary pulmonary hypertension (PPH), and 10 of normal subjects (NL). Right ventricular systolic pressure (RVSP) was 32.9±13.9, 45.0±12.2, 88.3±17.1, and 21.2±4.5 mmHg, respectively. The end-systolic LAO view of the left ventricle was halved into septal and free-wall sides. The end-diastolic halves were determined in the same plane. Ejection fractions of the global left ventricle (LVEF), global right ventricle (RVEF), the septal half of the left ventricle (SEPEF), and the free-wall half of the left ventricle (FWEF) were obtained. LVEF was 56.8±9.8% in NL, 52.8±10.5% in ASD, and 49.5±12.9% in PPH. In MS, LVEF (47.0±13.0%) was smaller than those in the other groups. RVEF was 37.0±5.2% in NL, 43.7±15.5% in ASD, and 32.8±11.5% in MS. In PPH, RVEF (25.0±10.6%) was smaller than those in the other groups. SEPEF was smaller in ASD (42.5±13.2%), MS (40.4±13.1%), PPH (40.5±12.5%) than in NL (53.5±8.5%). Systolic function of the septal half of the left ventricle was disturbed by right ventricular overload. RVEF (r=-0.35, p<0.05) and SEPEF (r=-0.51, p<0.01) had negative correlations with RVSP. As RVSP rose, systolic function of the septal half of the left ventricle was more severely disturbed. FWEF was the same among the four groups; NL (57.0±12.6%), ASD (48.6±15.2%), MS (50.5±12.0%), and PPH (51.1±12.3%). There was a good correlation between SEPEF and LVEF in NL (r=0.81), although in PPH this correlation was poor (r=0.64). These data showed that the distorted left ventricular due to right ventricular overload maintains its global function with preserved function of the free-wall side. (J.P.N.)

  18. Functional reserve of the ischemic left ventricle with ventricular aneurysm to afterload stress

    International Nuclear Information System (INIS)

    Tsuiki, Kai; Kobayashi, Tadashi; Hayasaka, Makio

    1985-01-01

    The response of left ventricular function to afterload stress was assessed using DSA for eight patients with old anterior myocardial infarction and ventricular aneurysm including that of the anterior wall. After initial DSA in the basal state, methoxamine was infused intravenously (1 to 2 mg/min). When aortic systolic blood pressure increased by 30 to 50 mmHg, a second DSA was performed for each patient. Left ventricular volumes and ejection fractions were calculated by the area-length method, and regional wall motion was assessed by the visual method according to the AHA classification and the curvature radius of the apical ventricular aneurysm was calculated. Methoxamine induced neither acute heart failure nor angina pectoris in the present series. The heart rates decreased, and there were a significant increase in end-systolic volumes (p ES ). However, ΔESV and ΔR ES did not correlate; ΔR ES was much greater in two patients, who were relatively old. Their aneurysms were circumscribed within the left ventricular anterior wall, their ejection fractions were relatively increased; and their onsets of acute myocardial infarction were relatively recent. (J.P.N.)

  19. High baseline left ventricular and systolic volume may identify patients at risk of chemotherapy-induced cardiotoxicity

    International Nuclear Information System (INIS)

    Atiar Rahman; Alex Gedevanishvili; Seham Ali; Elma G Briscoe; Vani Vijaykumar

    2004-01-01

    Introduction and Methods: Use of chemotherapeutic drugs in the treatment of cancer may lead to serious cardiotoxicity and to post-treatment heart failure. Various strategies have been developed to minimize the risk of cardiotoxicity including avoiding the total dosage given to each patient above a certain 'threshold' value; and monitoring the patient's cardiac function by means of the 'Multiple Gated Acquisition' (MUGA) scan using Technetium 99m . However, even with all these precautions some patients still develop cardiotoxicity and it is not well known which factors predict deterioration of cardiac functions in patients with optimized chemotherapeutic dosages. In this retrospective study we sought to evaluate the predictive value of seven variables (age, sex, baseline LV ejection fraction, LV end diastolic [LDEDV] and end systolic volumes [LVESV], peak diastolic filling rate, preexisting malignancies requiring chemotherapy) in 172 patients (n=Breast Carcinoma 86, lymphoma 62, Leukemias and others 24) undergoing chemotherapy from 1995 until 2000. There was no cut off for left ventricular ejection fraction prior to chemotherapy. However, patients were excluded from analysis if they had significant cardiac arrhythmias or received doses higher than considered safe for cardiotoxicity at the beginning of the study. Significant cardiotoxicity was defined as a drop in post chemotherapy LVEF by >15%. Results: Logistic regression models were used to predict the probability of developing cardiotoxicity as a function of the seven prognostic covariates. The mean age of all patients was 51+13 years. Significant Cardiac toxicity was noted in 10 percent of patients. The overall risk estimate for subsequent heart failure after chemotherapy, however, climbed to 18 percent in patients with a presenting LVESD >50 mL. Using multivariate logistic regression model, older age was noted to be a weak risk factors for cardiac toxicity (confidence interval 0.8-1.2; p 50 mL) appeared to

  20. Assessment of dedicated low-dose cardiac micro-CT reconstruction algorithms using the left ventricular volume of small rodents as a performance measure

    Energy Technology Data Exchange (ETDEWEB)

    Maier, Joscha, E-mail: joscha.maier@dkfz.de [Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Sawall, Stefan; Kachelrieß, Marc [Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany and Institute of Medical Physics, University of Erlangen–Nürnberg, 91052 Erlangen (Germany)

    2014-05-15

    Purpose: Phase-correlated microcomputed tomography (micro-CT) imaging plays an important role in the assessment of mouse models of cardiovascular diseases and the determination of functional parameters as the left ventricular volume. As the current gold standard, the phase-correlated Feldkamp reconstruction (PCF), shows poor performance in case of low dose scans, more sophisticated reconstruction algorithms have been proposed to enable low-dose imaging. In this study, the authors focus on the McKinnon-Bates (MKB) algorithm, the low dose phase-correlated (LDPC) reconstruction, and the high-dimensional total variation minimization reconstruction (HDTV) and investigate their potential to accurately determine the left ventricular volume at different dose levels from 50 to 500 mGy. The results were verified in phantom studies of a five-dimensional (5D) mathematical mouse phantom. Methods: Micro-CT data of eight mice, each administered with an x-ray dose of 500 mGy, were acquired, retrospectively gated for cardiac and respiratory motion and reconstructed using PCF, MKB, LDPC, and HDTV. Dose levels down to 50 mGy were simulated by using only a fraction of the projections. Contrast-to-noise ratio (CNR) was evaluated as a measure of image quality. Left ventricular volume was determined using different segmentation algorithms (Otsu, level sets, region growing). Forward projections of the 5D mouse phantom were performed to simulate a micro-CT scan. The simulated data were processed the same way as the real mouse data sets. Results: Compared to the conventional PCF reconstruction, the MKB, LDPC, and HDTV algorithm yield images of increased quality in terms of CNR. While the MKB reconstruction only provides small improvements, a significant increase of the CNR is observed in LDPC and HDTV reconstructions. The phantom studies demonstrate that left ventricular volumes can be determined accurately at 500 mGy. For lower dose levels which were simulated for real mouse data sets, the

  1. Assessment of dedicated low-dose cardiac micro-CT reconstruction algorithms using the left ventricular volume of small rodents as a performance measure

    International Nuclear Information System (INIS)

    Maier, Joscha; Sawall, Stefan; Kachelrieß, Marc

    2014-01-01

    Purpose: Phase-correlated microcomputed tomography (micro-CT) imaging plays an important role in the assessment of mouse models of cardiovascular diseases and the determination of functional parameters as the left ventricular volume. As the current gold standard, the phase-correlated Feldkamp reconstruction (PCF), shows poor performance in case of low dose scans, more sophisticated reconstruction algorithms have been proposed to enable low-dose imaging. In this study, the authors focus on the McKinnon-Bates (MKB) algorithm, the low dose phase-correlated (LDPC) reconstruction, and the high-dimensional total variation minimization reconstruction (HDTV) and investigate their potential to accurately determine the left ventricular volume at different dose levels from 50 to 500 mGy. The results were verified in phantom studies of a five-dimensional (5D) mathematical mouse phantom. Methods: Micro-CT data of eight mice, each administered with an x-ray dose of 500 mGy, were acquired, retrospectively gated for cardiac and respiratory motion and reconstructed using PCF, MKB, LDPC, and HDTV. Dose levels down to 50 mGy were simulated by using only a fraction of the projections. Contrast-to-noise ratio (CNR) was evaluated as a measure of image quality. Left ventricular volume was determined using different segmentation algorithms (Otsu, level sets, region growing). Forward projections of the 5D mouse phantom were performed to simulate a micro-CT scan. The simulated data were processed the same way as the real mouse data sets. Results: Compared to the conventional PCF reconstruction, the MKB, LDPC, and HDTV algorithm yield images of increased quality in terms of CNR. While the MKB reconstruction only provides small improvements, a significant increase of the CNR is observed in LDPC and HDTV reconstructions. The phantom studies demonstrate that left ventricular volumes can be determined accurately at 500 mGy. For lower dose levels which were simulated for real mouse data sets, the

  2. Assessment of dedicated low-dose cardiac micro-CT reconstruction algorithms using the left ventricular volume of small rodents as a performance measure.

    Science.gov (United States)

    Maier, Joscha; Sawall, Stefan; Kachelrieß, Marc

    2014-05-01

    Phase-correlated microcomputed tomography (micro-CT) imaging plays an important role in the assessment of mouse models of cardiovascular diseases and the determination of functional parameters as the left ventricular volume. As the current gold standard, the phase-correlated Feldkamp reconstruction (PCF), shows poor performance in case of low dose scans, more sophisticated reconstruction algorithms have been proposed to enable low-dose imaging. In this study, the authors focus on the McKinnon-Bates (MKB) algorithm, the low dose phase-correlated (LDPC) reconstruction, and the high-dimensional total variation minimization reconstruction (HDTV) and investigate their potential to accurately determine the left ventricular volume at different dose levels from 50 to 500 mGy. The results were verified in phantom studies of a five-dimensional (5D) mathematical mouse phantom. Micro-CT data of eight mice, each administered with an x-ray dose of 500 mGy, were acquired, retrospectively gated for cardiac and respiratory motion and reconstructed using PCF, MKB, LDPC, and HDTV. Dose levels down to 50 mGy were simulated by using only a fraction of the projections. Contrast-to-noise ratio (CNR) was evaluated as a measure of image quality. Left ventricular volume was determined using different segmentation algorithms (Otsu, level sets, region growing). Forward projections of the 5D mouse phantom were performed to simulate a micro-CT scan. The simulated data were processed the same way as the real mouse data sets. Compared to the conventional PCF reconstruction, the MKB, LDPC, and HDTV algorithm yield images of increased quality in terms of CNR. While the MKB reconstruction only provides small improvements, a significant increase of the CNR is observed in LDPC and HDTV reconstructions. The phantom studies demonstrate that left ventricular volumes can be determined accurately at 500 mGy. For lower dose levels which were simulated for real mouse data sets, the HDTV algorithm shows the

  3. Left Ventricular Function Improves after Pulmonary Valve Replacement in Patients with Previous Right Ventricular Outflow Tract Reconstruction and Biventricular Dysfunction

    Science.gov (United States)

    Kane, Colin; Kogon, Brian; Pernetz, Maria; McConnell, Michael; Kirshbom, Paul; Rodby, Katherine; Book, Wendy M.

    2011-01-01

    Congenital heart defects that have a component of right ventricular outflow tract obstruction, such as tetralogy of Fallot, are frequently palliated in childhood by disruption of the pulmonary valve. Although this can provide an initial improvement in quality of life, these patients are often left with severe pulmonary valve insufficiency. Over time, this insufficiency can lead to enlargement of the right ventricle and to the deterioration of right ventricular systolic and diastolic function. Pulmonary valve replacement in these patients decreases right ventricular volume overload and improves right ventricular performance. To date, few studies have examined the effects of pulmonary valve replacement on left ventricular function in patients with biventricular dysfunction. We sought to perform such an evaluation. Records of adult patients who had undergone pulmonary valve replacement from January 2003 through November 2006 were analyzed retrospectively. We reviewed preoperative and postoperative echocardiograms and calculated left ventricular function in 38 patients. In the entire cohort, the mean left ventricular ejection fraction increased by a mean of 0.07 after pulmonary valve replacement, which was a statistically significant change (P < 0.01). In patients with preoperative ejection fractions of less than 0.50, mean ejection fractions increased by 0.10. We conclude that pulmonary valve replacement in patients with biventricular dysfunction arising from severe pulmonary insufficiency and right ventricular enlargement can improve left ventricular function. Prospective studies are needed to verify this finding. PMID:21720459

  4. Left Ventricular Assist Devices

    Directory of Open Access Journals (Sweden)

    Khuansiri Narajeenron

    2017-04-01

    Full Text Available Audience: The audience for this classic team-based learning (cTBL session is emergency medicine residents, faculty, and students; although this topic is applicable to internal medicine and family medicine residents. Introduction: A left ventricular assist device (LVAD is a mechanical circulatory support device that can be placed in critically-ill patients who have poor left ventricular function. After LVAD implantation, patients have improved quality of life.1 The number of LVAD patients worldwide continues to rise. Left-ventricular assist device patients may present to the emergency department (ED with severe, life-threatening conditions. It is essential that emergency physicians have a good understanding of LVADs and their complications. Objectives: Upon completion of this cTBL module, the learner will be able to: 1 Properly assess LVAD patients’ circulatory status; 2 appropriately resuscitate LVAD patients; 3 identify common LVAD complications; 4 evaluate and appropriately manage patients with LVAD malfunctions. Method: The method for this didactic session is cTBL.

  5. Preoperative left ventricular ejection fraction and left atrium reverse remodeling after mitral regurgitation surgery.

    Science.gov (United States)

    Machado, Lucia R; Meneghelo, Zilda M; Le Bihan, David C S; Barretto, Rodrigo B M; Carvalho, Antonio C; Moises, Valdir A

    2014-11-06

    Left atrium enlargement has been associated with cardiac events in patients with mitral regurgitation (MR). Left atrium reverse remodeling (LARR) occur after surgical correction of MR, but the preoperative predictors of this phenomenon are not well known. It is therefore important to identify preoperative predictors for postoperative LARR. We enrolled 62 patients with chronic severe MR (prolapse or flail leaflet) who underwent successful mitral valve surgery (repair or replacement); all with pre- and postoperative echocardiography. LARR was defined as a reduction in left atrium volume index (LAVI) of ≥ 25%. Stepwise multiple regression analysis was used to identify independent predictors of LARR. LARR occurred in 46 patients (74.2%), with the mean LAVI decreasing from 85.5 mL/m2 to 49.7 mL/m2 (p <0.001). These patients had a smaller preoperative left ventricular systolic volume (p =0.022) and a higher left ventricular ejection fraction (LVEF) (p =0.034). LVEF was identified as the only preoperative variable significantly associated with LARR (odds ratio, 1.086; 95% confidence interval, 1.002-1.178). A LVEF cutoff value of 63.5% identified patients with LARR of ≥ 25% with a sensitivity of 71.7% and a specificity of 56.3%. LARR occurs frequently after mitral valve surgery and is associated with preoperative LVEF higher than 63.5%.

  6. Quantitative gated SPECT: the effect of reconstruction filter on calculated left ventricular ejection fractions and volumes

    International Nuclear Information System (INIS)

    Wright, Graham A.; McDade, Mark; Martin, William; Hutton, William

    2002-01-01

    Gated SPECT (GSPECT) offers the possibility of obtaining additional functional information from perfusion studies, including calculation of left ventricular ejection fraction (LVEF). The calculation of LVEF relies upon the identification of the endocardial surface, which will be affected by the spatial resolution and statistical noise in the reconstructed images. The aim of this study was to compare LVEFs and ventricular volumes calculated from GSPECT using six reconstruction filters. GSPECT and radionuclide ventriculography (RNVG) were performed on 40 patients; filtered back projection was used to reconstruct the datasets with each filter. LVEFs and volumes were calculated using the Cedars-Sinai QGS package. The correlation coefficient between RNVG and GSPECT ranged from 0.81 to 0.86 with higher correlations for smoother filters. The narrowest prediction interval was 11±2%. There was a trend towards higher LVEF values with smoother filters, the ramp filter yielding LVEFs 2.55±3.10% (p<0.001) lower than the Hann filter. There was an overall fall in ventricular volumes with smoother filters with a mean difference of 13.98±10.15 ml (p<0.001) in EDV between the Butterworth-0.5 and Butterworth-0.3 filters. In conclusion, smoother reconstruction filters lead to lower volumes and higher ejection fractions with the QGS algorithm, with the Butterworth-0.4 filter giving the highest correlation with LVEFs from RNVG. Even if the optimal filter is chosen the uncertainty in the measured ejection fractions is still too great to be clinically acceptable. (author)

  7. Right and Left Ventricular Function and Mass in Male Elite Master Athletes: A Controlled Contrast-Enhanced Cardiovascular Magnetic Resonance Study.

    Science.gov (United States)

    Bohm, Philipp; Schneider, Günther; Linneweber, Lutz; Rentzsch, Axel; Krämer, Nadine; Abdul-Khaliq, Hashim; Kindermann, Wilfried; Meyer, Tim; Scharhag, Jürgen

    2016-05-17

    It is under debate whether the cumulative effects of intensive endurance exercise induce chronic cardiac damage, mainly involving the right heart. The aim of this study was to examine the cardiac structure and function in long-term elite master endurance athletes with special focus on the right ventricle by contrast-enhanced cardiovascular magnetic resonance. Thirty-three healthy white competitive elite male master endurance athletes (age range, 30-60 years) with a training history of 29±8 years, and 33 white control subjects pair-matched for age, height, and weight underwent cardiopulmonary exercise testing, echocardiography including tissue-Doppler imaging and speckle tracking, and cardiovascular magnetic resonance. Indexed left ventricular mass and right ventricular mass (left ventricular mass/body surface area, 96±13 and 62±10 g/m(2); Pright ventricular mass/body surface area, 36±7 and 24±5 g/m(2); Pleft ventricular end-diastolic volume and right ventricular end-diastolic volume (left ventricular end-diastolic volume/body surface area, 104±13 and 69±18 mL/m(2); Pright ventricular end-diastolic volume/body surface area, 110±22 and 66±16 mL/m(2); PRight ventricular ejection fraction did not differ between athletes and control subjects (52±8 and 54±6%; P=0.26). Pathological late enhancement was detected in 1 athlete. No correlations were found for left ventricular and right ventricular volumes and ejection fraction with N-terminal pro-brain natriuretic peptide, and high-sensitive troponin was negative in all subjects. Based on our results, chronic right ventricular damage in elite endurance master athletes with lifelong high training volumes seems to be unlikely. Thus, the hypothesis of an exercise-induced arrhythmogenic right ventricular cardiomyopathy has to be questioned. © 2016 American Heart Association, Inc.

  8. Left ventricular apical ballooning syndrome

    International Nuclear Information System (INIS)

    Rahman, N.; Tai, J.; Soofi, A.

    2007-01-01

    The transient left ventricular apical ballooning syndrome, also known as Takotsubo cardiomyopathy, is characterized by transient left ventricular dysfunction in the absence of obstructive epicardial coronary disease. Although the syndrome has been reported in Japan since 1990, it is rare in other regions. Rapid recognition of the syndrome can modify the diagnostic and therapeutic attitude i.e. avoiding thrombolysis and performing catheterization in the acute phase. (author)

  9. Predictors of the left ventricular dysfunction induced by ventricular arrhythmia

    Directory of Open Access Journals (Sweden)

    А. І. Vytryhovskiy

    2016-08-01

    Full Text Available The most powerful predictor of life-threatening arrhythmia risk is a combination of low heart rate variability with low ejection fraction (EF of the left ventricle. Aim. To identify predictors of left ventricle dysfunction which is induced by ventricular arrhythmia. Materials and methods. To diagnose structural changes of left ventricular functional capacity and reserves in patients with previous myocardial infarction and patients with high and very high cardiovascular risk by SCORE scale and for establishment the relationship between morphological heart changes and pathological phenomenon of heart turbulence echocardiography and study of heart rate turbulence variability were performed. 603 patients were selected for the research. All patients were divided into groups: group 1 – patients with coronary heart disease, but without associated risk factors, such as smoking, obesity, metabolic syndrome; group 2 – patients who smoke tobacco more than 2 years (very high cardiovascular risk by scale SCORE; group 3 – patients with metabolic syndrome without coronary heart disease or arterial hypertension (very high cardiovascular risk by scale SCORE. The control group consisted of 149 persons. Results. The feature of structural changes in patients with myocardial infarction and in patients with a high cardiovascular risk by SCORE with heart rate turbulence compared with cases without НRT is considerably thickening of the left interventricular septum in systole. Based on this, it can be argued that the emergence of ventricular arrhythmia and accordingly phenomenon of heart rate turbulence in patients with existing cardiovascular diseases and risk factors has both morphological and functional character. Significant difference of echocardioscopy parameters in patients with postinfarction cardiosclerosis and risk factors by the SCORE system was established by index of intraventricular septum thickness in systole, and in persons with high risk – in

  10. Evaluation of left ventricular function by nuclear stethoscope

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko

    1981-01-01

    The Nuclear Stethoscope (N.S.) is a unique cardiac probe system that provides a precise, rapid, noninvasive method to directly quantify ventricular functions at the bedside or actual beat-to-beat or composite beat basis. The accuracy and validity of N.S. were studied in 42 patients with cardiac diseases in comparison with camera-computer EF. The N.S. EF was well correlated with camera-computer EF (r = 0.82). In this study, clinical application of N.S. was as follows. 1. Beat-to-beat left ventricular volume response for evaluation of arrythmia (atrial fibrillation, premature ventricular conduction, bigemy et al.) 2. exercise study by handgrip and ergometer. EF is an extremely sensitive indicator to discriminate coronary arteries diseases from normal subjects. (author)

  11. Evaluation of left ventricular function by nuclear stethoscope

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, T [National Cardiovascular Center, Suita, Osaka (Japan)

    1981-03-01

    The Nuclear Stethoscope (N.S.) is a unique cardiac probe system that provides a precise, rapid, noninvasive method to directly quantify ventricular functions at the bedside or actual beat-to-beat or composite beat basis. The accuracy and validity of N.S. were studied in 42 patients with cardiac diseases in comparison with camera-computer EF. The N.S. EF was well correlated with camera-computer EF (r = 0.82). In this study, clinical application of N.S. was as follows. 1. Beat-to-beat left ventricular volume response for evaluation of arrythmia (atrial fibrillation, premature ventricular conduction, bigemy et al.) 2. exercise study by handgrip and ergometer. EF is an extremely sensitive indicator to discriminate coronary arteries diseases from normal subjects.

  12. Relationship of left ventricular systolic function to persistence or development of electrocardiographic left ventricular hypertrophy in hypertensive patients

    DEFF Research Database (Denmark)

    Okin, Peter M; Wachtell, Kristian; Gerdts, Eva

    2014-01-01

    left ventricular systolic function in patients with new or persistent ECG LVH. METHODS: Baseline and year-3 ECG LVH and left ventricular midwall shortening (MWS) were examined in 725 hypertensive patients in the Losartan Intervention For Endpoint reduction in hypertension (LIFE) echocardiographic...... 1.03-3.50, P = 0.040) at year 3. CONCLUSION: Persistence or development of new ECG LVH during antihypertensive therapy is associated with an increased risk of left ventricular systolic dysfunction after 3 years' follow-up. These findings provide insight into a possible mechanism by which changes......BACKGROUND: Persistence or development of ECG left ventricular hypertrophy (LVH) by Cornell product criteria is associated with an increased risk of developing heart failure compared with regression or continued absence of LVH. We postulated that this association might be in part mediated via worse...

  13. Precision of gated equilibrium radioventriculography in measuring left ventricular stroke volume

    International Nuclear Information System (INIS)

    Bourguignon, M.H.; Wise, R.A.; Ehrlich, W.E.; Douglas, K.H.; Camargo, E.E.; Harrison, K.E.; Wagner, H.N. Jr.

    1983-01-01

    We have demonstrated that relative changes of small amplitude in ventricular stroke volume can be measured accurately in dogs when a fully automated technique for delineation of end diastolic and end systolic region of interest (ROI) is used. Consequently, we expect such a technique to be very sensitive in measuring relative changes of any ventricular quantitative parameter from gated equilibrium radio ventriculography in humans

  14. Quantification of left ventricular function by gated myocardial perfusion SPECT using multidimTM

    International Nuclear Information System (INIS)

    Huang Jin; Song Wenzhong; Chen Mingxi

    2004-01-01

    Objective: To evaluate the accuracy of left ventricular function by gated SPECT using the software Multidim TM . Methods: Rest gated SPECT was performed on 42 cases involved 26 normal subjects and 16 patients with myocardial infarct (MI). All cases underwent rest equilibrium radionuclide angiocardiography (ERNA) within 1 w. Results: (1)End diastolic volume (EDV), end systolic volume (ESV) and left ventricular ejection fraction(LVEF)were calculated using the software MultidimtMand ERNA. The correlation coefficient between the two Methods was 0.90,0.89,0.92 respectively(P TM , but the EDV and ESV value measured by this software maybe high with small heart. (authors)

  15. Remote Zone Extracellular Volume and Left Ventricular Remodeling in Survivors of ST-Elevation Myocardial Infarction

    Science.gov (United States)

    Carberry, Jaclyn; Carrick, David; Haig, Caroline; Rauhalammi, Samuli M.; Ahmed, Nadeem; Mordi, Ify; McEntegart, Margaret; Petrie, Mark C.; Eteiba, Hany; Hood, Stuart; Watkins, Stuart; Lindsay, Mitchell; Davie, Andrew; Mahrous, Ahmed; Ford, Ian; Sattar, Naveed; Welsh, Paul; Radjenovic, Aleksandra; Oldroyd, Keith G.

    2016-01-01

    The natural history and pathophysiological significance of tissue remodeling in the myocardial remote zone after acute ST-elevation myocardial infarction (STEMI) is incompletely understood. Extracellular volume (ECV) in myocardial regions of interest can now be measured with cardiac magnetic resonance imaging. Patients who sustained an acute STEMI were enrolled in a cohort study (BHF MR-MI [British Heart Foundation Magnetic Resonance Imaging in Acute ST-Segment Elevation Myocardial Infarction study]). Cardiac magnetic resonance was performed at 1.5 Tesla at 2 days and 6 months post STEMI. T1 modified Look-Locker inversion recovery mapping was performed before and 15 minutes after contrast (0.15 mmol/kg gadoterate meglumine) in 140 patients at 2 days post STEMI (mean age: 59 years, 76% male) and in 131 patients at 6 months post STEMI. Remote zone ECV was lower than infarct zone ECV (25.6±2.8% versus 51.4±8.9%; Premote zone ECV (Premote zone ECV (P=0.010). No ST-segment resolution (P=0.034) and extent of ischemic area at risk (Premote zone ECV at 6 months (ΔECV). ΔECV was a multivariable associate of the change in left ventricular end-diastolic volume at 6 months (regression coefficient [95% confidence interval]: 1.43 (0.10–2.76); P=0.036). ΔECV is implicated in the pathophysiology of left ventricular remodeling post STEMI, but because the effect size is small, ΔECV has limited use as a clinical biomarker of remodeling. Clinical Trial Registration— URL: https://www.clinicaltrials.gov. Unique identifier: NCT02072850. PMID:27354423

  16. Effect of age on left ventricular function during exercise in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Hakki, A.H.; DePace, N.L.; Iskandrian, A.S.

    1983-01-01

    The purpose of this study was to assess the effect of age on left ventricular performance during exercise in 79 patients with coronary artery disease (greater than or equal to 50% narrowing of one or more major coronary arteries). Fifty patients under the age of 60 years (group I) and 29 patients 60 years or older (group II) were studied. Radionuclide angiograms were obtained at rest and during symptom-limited upright bicycle exercise. The history of hypertension, angina or Q wave myocardial infarction was similar in both groups. Multivessel coronary artery disease was present in 30 patients (60%) in group I and in 19 patients (66%) in group II (p . not significant). There were no significant differences between the two groups in the hemodynamic variables (at rest or during exercise) of left ventricular ejection fraction, end-diastolic volume, end-systolic volume and cardiac index. Exercise tolerance was higher in group I than in group II (7.8 +/- 0.4 versus 5.7 +/- 0.4 minutes, p . 0.009), although the exercise heart rate and rate-pressure product were not significantly different between the groups. There was poor correlation between age and ejection fraction, end-diastolic volume and end-systolic volume at rest and during exercise. Abnormal left ventricular function at rest or an abnormal response to exercise was noted in 42 patients (84%) in group I and in 25 patients (86%) in group II (p . not significant). Thus, in patients with coronary artery disease, age does not influence left ventricular function at rest or response to exercise. Older patients with coronary artery disease show changes in left ventricular function similar to those in younger patients with corresponding severity of coronary artery disease

  17. Cardiac magnetic resonance imaging for evaluation of non-compaction cardiomyopathy in patients with or without left ventricular systolic dysfunction

    International Nuclear Information System (INIS)

    Deviggiano, A.; Deschle, H.; Lewkowicz, J.M.; Tajer, C.D.; Carrascosa, P.; Capunay, C.; Vallejos, J.; Stewart Harris, A.

    2011-01-01

    Background: Non-compaction cardiomyopathy (NCC) is a genetic disorder characterized by deep trabeculations in the ventricular wall, which define recesses communicating with the main ventricular chamber. The prevalence of NCC is greater in symptomatic populations with left ventricular dysfunction; yet, it may also be detected in asymptomatic patients with normal left ventricular function using novel diagnostic tools. However, this condition is under-diagnosed due to a low index of clinical suspicion and to the use of echocardiography classifications based on different diagnostic criteria. The use of cardiac magnetic resonance imaging (CMRI) has established two diagnostic criteria that clearly recognize this disease. Objective: To evaluate the clinical and morphological characteristics of patients with NCC with and without systolic dysfunction undergoing cardiac magnetic resonance imaging (CMRI). Material and Methods: A total of 20 patients with NCC were retrospectively included. The following parameters were determined: left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV); left ventricular end-diastolic diameter (LVEDD); left ventricular end-systolic diameter (LVESD); cardiac mass and left ventricular trabeculations. The distribution of NC myocardium was evaluated according to the model of 17 myocardial segments. Results: Mean myocardial thickness was 13.1 ± 3.3 mm and 3.6 ± 0.6 mm in NC versus normal myocardium, respectively. Patients with left ventricular dysfunction presented increased LVEDD, LVEDV, total cardiac mass, and LV non-compaction and trabeculations. We found a positive correlation and a linear relationship between LVEDD and TLVM (g/m 2 ): r=0.76; r 2 =0.59; p [es

  18. Cardiovascular effects of contrast materials on left ventricular angiography in rabbits

    International Nuclear Information System (INIS)

    Yeon, Kyung Mo; Han, Man Chung; Kim, Chu Wan

    1985-01-01

    The precise pathologic anatomy in complex congenital heart disease requires multiple injections of iodinated contrast materials into the cardiac chambers and/or great vessels. In the presence of intracardial shunts, more large volumes of contrast material is often required. In neonates and infants the total volume of contrast material during single angiographic procedure is limited up to 3-4ml/kg. This limitation results from the deleterious effects of systemic hyperosmolarity caused by the contrast materials and may be intensified in the neonate because of the relative immaturity of infants kidneys and delayed excretion of contrast materials. We therefore tried to compare the EKG and left ventricular pressure change with those of high osmolar and low osmolar contrast agent in experimental model. The purpose of the study is to determine and compare the effects of contrast materials on left ventricular hemodynamics

  19. Real-time scintillation probe measurement of left ventricular function

    International Nuclear Information System (INIS)

    Green, M.V.; Ostrow, H.G.; Bacharach, S.L.; Allen, S.I.; Bonow, R.O.; Johnston, G.S.

    1981-01-01

    The micro-processor based system described in this report was designed for maximum flexibility and utility. While the principle function of the system is to acquire, create, analyze and display (in real-time) left ventricular time activity (or volume) curves, provision is also made to acquire additional physiologic signals (e.g., ECG, flowmeter, etc.) and to calculate and display relationships between these various data. The system was designed for interactive use so that the system user can alter the course of a series of measurements based on previous results. These general capabilities are illustrated with several examples. In the first, LV function was measured continuously in a subject from (supine) rest through exercise and recovery. The second example illustrates the use of the system in acquiring (LV) pressure-volume loops. Several technical problems, such as correction for LV background radiation, appear at present to limit the probes applicability. Even now, however, probe systems are demonstrably useful in the study of global left ventricular function when this function is changing rapidly with time in response to various interventions. (orig.) [de

  20. Assessment of cardiac blood pool imaging in patients with left ventricular outflow tract stenosis

    International Nuclear Information System (INIS)

    Nakamura, Yutaka; Ono, Yasuo; Kohata, Tohru; Tsubata, Shinichi; Kamiya, Tetsuroh.

    1993-01-01

    We performed cardiac blood pool imagings with Tc-99m at rest and during supine ergometer exercise to evaluate left ventricular performance in 14 patients with left ventricular outflow tract stenosis. All catheterized patients were divided into two subgroups: 8 patients with peak systolic left ventricular to descending aortic pressure gradients of less than 50 mmHg (LPG group) and 6 patients with peak systolic gradients of more than 50 mmHg (HPG group). Control group included 10 patients without stenotic coronary lesions after Kawasaki disease. Left ventricular ejection fraction (LVEF) was obtained as systolic index; both filling fraction during the first third of diastole (1/3FF) and mean filling rate during the first third of diastole (1/3FR mean) were obtained as diastolic indices. None of the patients had abnormal findings on 201 Tl imaging. LVEF at rest in HPG group was significantly higher than those in control group, but LVEF in HPG group did not increase after exercise. It increased significantly in control group and LPG group. 1/3 FF in HPG group was significantly lower not only at rest but also during exercise. 1/3 FR mean at rest was not different significantly among the 3 groups. However, 1/3FR mean during exercise in LPG group was significantly lower; and 1/3 FR mean during exercise was significantly lower in HPG group than LPG group. The ratio of left ventricular muscular mass to left ventricular end-diastolic volume (M/V) calculated from left ventricular cineangiograms was different significantly among the 3 groups. The M/V ratio showed a correlation with LVEF and 1/3 FF both at rest and during exercise. These results would indicate that systolic function was impaired on exercise in severe left ventricular outflow tract stenosis and diastolic function was impaired on exercise in mild and severe left ventricular outflow tract stenosis. This may correlate with left ventricular hypertrophy and interaction of systolic function. (author)

  1. A newly developed maneuver, field change conversion (FCC), improved evaluation of the left ventricular volume more accurately on quantitative gated SPECT (QGS) analysis

    International Nuclear Information System (INIS)

    Tajima, Osamu; Shibasaki, Masaki; Hoshi, Toshiko; Imai, Kamon

    2002-01-01

    The purpose of this study was to investigate whether a newly developed maneuver that reduces the reconstruction area by a half more accurately evaluates left ventricular (LV) volume on quantitative gated SPECT (QGS) analysis. The subjects were 38 patients who underwent left ventricular angiography (LVG) followed by G-SPECT within 2 weeks. Acquisition was performed with a general purpose collimator and a 64 x 64 matrix. On QGS analysis, the field magnification was 34 cm in original image (Original: ORI), and furthermore it was changed from 34 cm to 17 cm to enlarge the re-constructed image (Field Change Conversion: FCC). End-diastolic volume (EDV) and end-systolic volume (ESV) of the left ventricle were also obtained using LVG. EDV was 71±19 ml, 83±20 ml and 98±23 ml for ORI, FCC and LVG, respectively (p<0.001: ORI versus LVG, p<0.001: ORI versus FCC, p<0.001: FCC versus LVG). ESV was 28±12 ml, 34±13 ml and 41±14 ml for ORI, FCC and LVG, respectively (p<0.001: ORI versus LVG, p<0.001: ORI versus FCC, p<0.001: FCC versus LVG). FCC was better than ORI for calculating LV volume in clinical cases. Furthermore, FCC is a useful method for accurately measuring the LV volume on QGS analysis. (author)

  2. Left ventricular systolic and diastolic function in hyperthyroidism

    International Nuclear Information System (INIS)

    Friedman, M.J.; Okada, R.D.; Ewy, G.A.; Hellman, D.J.

    1982-01-01

    In order to assess the effect of hyperthyroidism on systolic and diastolic function of the left ventricle, M-mode echocardiograms and systolic time intervals were obtained in 13 patients while they were clinically hyperthyroid and again when they were euthyroid following radioactive iodine therapy. Echocardiographic tracings of the septum and left ventricular posterior wall were digitized and analyzed to provide the maximum velocity of shortening and maximum velocity of lengthening. These velocities were normalized for left ventricular diastolic dimension. The left ventricular minor axis fractional shortening and the normalized maximum velocity of shortening were both increased during the hyperthyroid state. The normalized maximum velocity of lengthening, a measure of diastolic left ventricular function, was also increased during the hyperthyroid state when compared to the euthyroid state. The preejection period index and the preejection period/left ventricular ejection time ratio were lower when the patients were hyperthyroid than when they were euthyroid. These data confirm the increased inotropic state and demonstrated increased diastolic relaxation velocities of the hyperthyroid left ventricle

  3. Factors of Formation of Various Types of Left Ventricular Diastolic Filling in Adolescents with Myocardium Pathology

    Directory of Open Access Journals (Sweden)

    L.F. Bogmat

    2016-08-01

    of general peripheral vascular resistance and cardiac output, and geometric one includes left atrial diameter and the left ventricular end-diastolic size. Formation of left ventricular diastolic dysfunction type 3 is influenced by such components of the neurohormonal system, as renin and angiotensin-II, then the process subsequently includes peripheral vascular tone and a geometric factor in the form of left atrial diameter and left ventricular end-diastolic size. Thus, in the initial stages of left ventricular diastolic dysfunction in adolescents with myocardial pathology, a significant role is played by the sympathoadrenal system, peripheral vascular tone and left atrial function, and then sequentially the renin-angiotensin system is being involved, which causes an increase in myocardial stiffness and, as a result, the inclusion in the pathological process not only of the left atrium, but also the structure (end-diastolic volume and function of the left ventricle (stroke volume.

  4. Left-ventricular reduction surgery: pre- and postoperative evaluation by cine magnetic resonance imaging

    International Nuclear Information System (INIS)

    Kivelitz, D.E.; Enzweiler, C.N.H.; Wiese, T.H.; Lembcke, A.; Hamm, B.; Hotz, H.; Konertz, W.; Borges, A.C.; Baumann, G.

    2001-01-01

    Aim: To evaluate the role of cine magnetic resonance imaging (MRI) in the preoperative assessment and postoperative follow-up of patients undergoing left ventricular (LV) reduction surgery. Patients and Methods: 6 patients with cardiomegaly were examined on a 1.5 T MR imager before and after LV reduction surgery. The heart was imaged along the short and long axes using a breath-hold ECG-triggered cine gradient-echo sequence for assessing ventricular and valvular morphology and function and performing volumetry (end-diastolic and end-systolic volumes, ejection fraction). Results: Postoperatively, the mean ejection fraction increased from 21.7% to 33.4% and the enddiastolic and end-systolic left ventricular volumes decreased in all patients (304.0 and 252.5 ml before to 205.0 and 141.9 ml after surgery). Mean myocardial mass decreased slightly from 283.8 g to 242.7 g. Differences were significant for all parameters (p [de

  5. Measurement and comparison of left ventricular ejection fraction utilizing first transit and gated scintiangiography

    International Nuclear Information System (INIS)

    Fletcher, J.W.; Herbig, F.K.; Daly, J.L.; Walter, K.E.

    1975-01-01

    Paired serial radionuclide scans were used for determinations of left ventricular ejection fraction (LVEF) in open chest dogs with constant cardiac output and varying ventricular rates following the left atrial injection of 99m-Tc human serum albumin. Values of LVEF obtained by first transit (high frequency) data analysis and ECG-gated scintiphotography were obtained over a wide range of ventricular rate and stroke volume. The results of this study show no significant difference in LVEF as determined by both of these methods of data acquisition and analysis and demonstrate the feasibility of rapid serial determination of LVEF by radioisotope techniques

  6. Left ventricular mass in male adolescent athletes and non-athletes

    Directory of Open Access Journals (Sweden)

    Erling David Kaunang

    2014-10-01

    Full Text Available Background Systematic exercise leads to increased left ventricular mass, which may be misleading in a differential diagnosis of heart disease in athletes (physiologic hypertrophy versus pathologic hypertrophy. T he cause of left ventricular hypertrophy is an important risk factor in the morbidity and mortality of cardiovascular diseases. Objective To compare left ventricular mass and left ventricular hypertrophy in male adolescent athletes and non-athletes. Methods We conducted a cross-sectional, analytic study, from September to December 2012 in male adolescents aged 15-18 years. The case group included athletes from the Bina Taruna Football Club Manado, while the control group included non-athlete adolescents. All subjects underwent history-taking, physical examinations and further supporting examinations. Left ventricular mass was measured by cardiovascular echocardiography (Esaote Mylab 4.0 and calculated based on a formula. Left ventricular hypertrophy was defined as left ventricular mass of > 134 g/m2 body surface area. Results Subjects' mean left ventricular masses were 359.69 (SD 188.4; 95%CI 283.58 to 435.81 grams in the athlete group and 173.04 (SD 50.69; 95%CI 152.56 to 103.51 grams in the non· athlete group, a statistically significant difference (P=0.0001. Ventricular hypertrophy was found 76.9% compared to 11.5% in  the non-athlete group (P= 0.0001. Conclusion Left ventricular mass in athletes is bigger than in non-athletes. In addition, left ventricular hypertrophy is more cornmon in male adolescent athletes than in non-athletes.

  7. The effect of postoperative medical treatment on left ventricular mass regression after aortic valve replacement.

    Science.gov (United States)

    Helder, Meghana R K; Ugur, Murat; Bavaria, Joseph E; Kshettry, Vibhu R; Groh, Mark A; Petracek, Michael R; Jones, Kent W; Suri, Rakesh M; Schaff, Hartzell V

    2015-03-01

    The study objective was to analyze factors associated with left ventricular mass regression in patients undergoing aortic valve replacement with a newer bioprosthesis, the Trifecta valve pericardial bioprosthesis (St Jude Medical Inc, St Paul, Minn). A total of 444 patients underwent aortic valve replacement with the Trifecta bioprosthesis from 2007 to 2009 at 6 US institutions. The clinical and echocardiographic data of 200 of these patients who had left ventricular hypertrophy and follow-up studies 1 year postoperatively were reviewed and compared to analyze factors affecting left ventricular mass regression. Mean (standard deviation) age of the 200 study patients was 73 (9) years, 66% were men, and 92% had pure or predominant aortic valve stenosis. Complete left ventricular mass regression was observed in 102 patients (51%) by 1 year postoperatively. In univariate analysis, male sex, implantation of larger valves, larger left ventricular end-diastolic volume, and beta-blocker or calcium-channel blocker treatment at dismissal were significantly associated with complete mass regression. In the multivariate model, odds ratios (95% confidence intervals) indicated that male sex (3.38 [1.39-8.26]) and beta-blocker or calcium-channel blocker treatment at dismissal (3.41 [1.40-8.34]) were associated with increased probability of complete left ventricular mass regression. Patients with higher preoperative systolic blood pressure were less likely to have complete left ventricular mass regression (0.98 [0.97-0.99]). Among patients with left ventricular hypertrophy, postoperative treatment with beta-blockers or calcium-channel blockers may enhance mass regression. This highlights the need for close medical follow-up after operation. Labeled valve size was not predictive of left ventricular mass regression. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  8. Determination of left and right ventricular ejection and filling by fast cine MR imaging in the breath-hold technique in healthy subjects

    International Nuclear Information System (INIS)

    Rominger, M.B.; Bachmann, G.F.; Geuer, M.; Puzik, M.; Rau, W.S.; Pabst, W.

    1999-01-01

    Purpose: Evaluation and comparison of localized and global left and right ventricular ejection and filling with fast cine MR imaging in the breath-hold technique. Materials and Methods: 10 healthy volunteers were examined with a 1.5 Tesla unit and phased-array-coil using a segmented FLASH-2D sequence in breath-hold technique. Peak ejection and peak filling rates [PER, PFR enddiastolic volume (EDV)/s], time to PER and PFR [TPER, TPFR ms] and time of endsystole [TSYS in % RR-intervall] of all slices (complete-slice-evaluation) were evaluated and compared to three left ventricular and one right ventricular slices (reduced three-slice-evaluation). Results: There were significant regional left ventricular differences of PER (p=0.002) and PFR (p=0.007), but not of TPER and TPFR. Ejection and filling indices of the left ventricular middle slice were closest to the overall evaluation of all sections. In the left-/right-side comparison the right ventricular PFR was higher than the left ventricular (5.1 and 4.2 EDV/s) and the right ventricular TPFR was earlier than the left (92.2 and 123.5 ms). Conclusions: With fast cine techniques, regional and global left and right ventricular ejection and filling indices can be evaluated in addition to the global heart volume indices. The three-slice-evaluation represents a comprehensive, clear and time-saving method for daily routine. (orig.) [de

  9. Evaluation of left ventricular function using digital subtraction angiography

    International Nuclear Information System (INIS)

    Kozuka, Takahiro; Ohta, Mitsushige

    1985-01-01

    To evaluate function of the left ventricle and myocardial perfusion images, digital subtraction angiography (DSA) was performed in 45 patients with ischemic heart disease. Validity of the technique was compared with data obtained from cine left ventriculogram in all patients and 201 T1 myocardial images in 20 patients. End-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) calculated from DSA were correlated closely with those from cine left ventriculogram (r = 0.92, r = 0.94 and r = 0.86, respectively). Regional contractility at the antero-lateral wall of the left ventricle, assessed by DSA, was also correlated well with cine left ventriculogram (r = 0.75). Evaluation of the inferior wall motion showed less correlation in both procedures (r = 0.68). Phase and amplitude analysis with the same technique with radionuclide cardiac angiography was successfully applied in left ventriculogram obtained by DSA. The procedure seems to be helpful for objective evaluation of the left ventricular wall motion. Myocardial perfusion image, obtained with modified Radtke's technique, showed good coincidence with 201 T1 images. Thus, DSA is applicable for evaluation of function of the left ventricle and myocardial perfusion in patients with ischemic heart disease. (author)

  10. Annular subvalvular left ventricular aneurysm in Bahia, Brazil.

    Science.gov (United States)

    Guimarães, A C; Filho, A S; Esteves, J P; Abreu, W N; Vinhaes, L A; de Almeida Souza, J A; Machado, A

    1976-10-01

    Two cases of left ventricular aneurysm, a 16-year-old black boy and a 23-year-old white girl, from Bahia, Brazil, are presented. In both patients there was enlargement of the cardiac silhouette and a prominent bulge of the left inferior border. On the right oblique view a ring of calcium at the ventricular opening of the aneurysms was visualized. A left ventriculogram showed a huge aneurysm in the first case and a bulge on the lateral wall of the left ventricle in the other. Cardiac catheterization showed a rise in left and right ventricular end-diastolic pressures and in the mean pulmonary artery pressure. In the first case the contour of the right ventricular pressure curve showed a restrictive pattern. The similarities of these aneurysms with the annular submitral type described in young black Africans are stressed.

  11. Assessment of left ventricular hemodynamics by Gd-DTPA enhanced high speed cine MRI

    International Nuclear Information System (INIS)

    Matsumura, Kentaro; Nakase, Emiko; Kawai, Ichiro

    1992-01-01

    To assess the validity of Gd-DTPA enhanced high speed cine MRI in left ventricular (LV) volumes and ejection fraction (EF), high speed cine MRI was compared with intra-venous digital subtraction left ventriculography (IV-DSA) in 14 patients. All patients underwent conventional cine MRI and Gd-DTPA enhanced high speed MRI, simultaneously. The pulse sequences of high speed MRI were TR 8 ms (TR 6 ms plus rewind pulse 2 ms), TE 3.2 ms, matrix 128, phase encode 8 or 6 and NEX 1. Comparison with LV-volume showed a high correlation (y = 0.854x + 1,699, r = 0.985) between high speed cine MRI and VI-DSA. To make left ventricular volume curve by area-length method in cine MRI, manual tracing of LV-cavity was more difficult in conventional cine MRI-method than enhanced high speed cine MRI-method. In conclusion, first pass-Gd-DTPA enhanced high speed cine MRI, using the horizontal long axis approach and the multiphase study, is a highly, accurate reproducible method of evaluating LV-volumetry. (author)

  12. The ratio of right ventricular volume to left ventricular volume reflects the impact of pulmonary regurgitation independently of the method of pulmonary regurgitation quantification

    International Nuclear Information System (INIS)

    Śpiewak, Mateusz; Małek, Łukasz A.; Petryka, Joanna; Mazurkiewicz, Łukasz; Miłosz, Barbara; Biernacka, Elżbieta K.; Kowalski, Mirosław; Hoffman, Piotr; Demkow, Marcin; Miśko, Jolanta; Rużyłło, Witold

    2012-01-01

    Background: Previous studies have advocated quantifying pulmonary regurgitation (PR) by using PR volume (PRV) instead of commonly used PR fraction (PRF). However, physicians are not familiar with the use of PRV in clinical practice. The ratio of right ventricle (RV) volume to left ventricle volume (RV/LV) may better reflect the impact of PR on the heart than RV end-diastolic volume (RVEDV) alone. We aimed to compare the impact of PRV and PRF on RV size expressed as either the RV/LV ratio or RVEDV (mL/m 2 ). Methods: Consecutive patients with repaired tetralogy of Fallot were included (n = 53). PRV, PRF and ventricular volumes were measured with the use of cardiac magnetic resonance. Results: RVEDV was more closely correlated with PRV when compared with PRF (r = 0.686, p 2.0 [area under the curve (AUC) PRV = 0.770 vs AUC PRF = 0.777, p = 0.86]. Conversely, with the use of the RVEDV-based criterion (>170 mL/m 2 ), PRV proved to be superior over PRF (AUC PRV = 0.770 vs AUC PRF = 0.656, p = 0.0028]. Conclusions: PRV and PRF have similar significance as measures of PR when the RV/LV ratio is used instead of RVEDV. The RV/LV ratio is a universal marker of RV dilatation independent of the method of PR quantification applied (PRF vs PRV)

  13. Left ventricular remodelling in chronic primary mitral regurgitation: implications for medical therapy.

    Science.gov (United States)

    McCutcheon, Keir; Manga, Pravin

    Surgical repair or replacement of the mitral valve is currently the only recommended therapy for severe primary mitral regurgitation. The chronic elevation of wall stress caused by the resulting volume overload leads to structural remodelling of the muscular, vascular and extracellular matrix components of the myocardium. These changes are initially compensatory but in the long term have detrimental effects, which ultimately result in heart failure. Understanding the changes that occur in the myocardium due to volume overload at the molecular and cellular level may lead to medical interventions, which potentially could delay or prevent the adverse left ventricular remodelling associated with primary mitral regurgitation. The pathophysiological changes involved in left ventricular remodelling in response to chronic primary mitral regurgitation and the evidence for potential medical therapy, in particular beta-adrenergic blockers, are the focus of this review.

  14. Effects of perfusion detect on the measurement of left ventricular mass, ventricular volume and post-stress left ventricular ejection fraction in gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Ahn, Byeong Cheol; Bae, Sun Keun; Lee, Sang Woo; Jeong, Sin Young; Lee, Jae Tae; Lee, Kyu Bo

    2002-01-01

    The presence of perfusion defect may influence the left ventricular mass (LVM) measurement by quantitative gated myocardial perfusion SPECT (QGS), and ischemic myocardium, usually showing perfusion defect may produce post-stress LV dysfunction. This study was aimed to evaluated the effects of extent and reversibility of perfusion defect on the automatic measurement of LVM by QGS and to investigate the effect of reversibility of perfusion defect on post-stress LV dysfunction. Forty-six patients (male/female=34:12, mean age=64 years) with perfusion defect on myocardial perfusion SPECT underwent rest and post-stress QGS. Forty patients (87%) showed reversible defect. End-diastolic volume (EDV), end-systolic volume (ESV), LV ejection fraction (EF), and LV myocardial volume were obtained from QGS by autoquant program, and LVM was calculated by multiplying the LV myocardial volume by the specific gravity of myocardium. LVMs measured at rest and post-stress QGS showed good correlation, and higher correlation was founded in the subjects with fixed perfusion defect and with small defect (smaller than 20%). There were no significant differences in EDVs, ESVs and EFs between obtained by rest and post-stress QGS in patients with fixed myocardial defect. Whereas, EF obtained by post-stress QGS was lower than that by rest QGS in patients with reversible defect and 10 (25%) of them showed decreases in EF more than 5% in post-stress QGS, as compared to that of rest QGS. Excellent correlations of EDVs, ESVs, EFs between rest and post-stress QGS were noted. Patients with fixed defect had higher correlation between defect can affect LVM measurement by QGS and patients with reversible defect shows post-stress LV dysfunction more frequently than patients with fixed perfusion defect

  15. Effect of eight weeks of endurance exercise training on right and left ventricular volume and mass in untrained obese subjects: a longitudinal MRI study

    DEFF Research Database (Denmark)

    Vogelsang, T W; Hanel, B; Kristoffersen, U S

    2008-01-01

    The aim of the present investigation was to examine how 8 weeks of intense endurance training influenced right and left ventricular volumes and mass in obese untrained subjects. Ten overweight subjects (19-47 years; body mass index of 34+/-5 kg/m(2)) underwent intensive endurance training (rowing......) and ventricular mass (VM) were measured by Magnetic resonance imaging (MRI). Submaximal heart rate decreased from 126+/-5 to 113+/-3 b.p.m. (10%; P...

  16. Evaluation of left ventricular function by digital subtraction angiography

    International Nuclear Information System (INIS)

    Kuribayashi, Sachio; Ootaki, Makoto; Matsuyama, Seiya; Kanemoto, Nariaki; Furuya, Hideo

    1985-01-01

    Effects of contrast medium doses on left ventriculographic images using intravenous digital subtraction angiography (IVDSA-LVG) were assessed. The validity of IVDSA-LVG in evaluating ejection fraction (FF) and left ventricular regional wall motion was determined by comparison with conventional left ventriculography using direct injection (direct LVG). The advantages of left ventriculography using intraarterial subtraction angiography (IADSA-LVG) performed by injecting small doses of contrast media directly into the left ventricle were stressed. 1. To assess the effects of doses of contrast media on IVDSA-LVG, 10, 20, and 30 ml Urografin-76 were injected into the superior vena cava in 16 patients, and the resulting images were compared in each patient. With only 10 ml contrast medium, left ventricular opacification was fairly good, and regional wall motion was evaluated in many cases, but 30 ml were needed to calculate ventricular volume and EF. 2. To determine the validity of IVDSA-LVG in evaluating EF and regional wall motion, we compared IVDSA-LVG using 30 ml of contrast medium with direct LVG in 18 patients. There was a good correlation between the two methods in determining EF (r = 0.877), and 90 % of the interpretations of regional wall motion were in agreement by the two methods. IVDSA-LVG was useful and accurate in evaluating EF and regional wall motion of the left ventricle. 3. IADSA-LVG was performed for five patients, and good quality images were obtained in many cases, even with relatively small doses (10 ml) of contrast media. These results suggested that this method may be used in cases with impaired LV function, to avoid hemodynamic derangement induced by conventional direct LVG using large doses of contrast medium. (author)

  17. Influence of left ventricular hypertrophy on infarct size and left ventricular ejection fraction in ST-elevation myocardial infarction

    International Nuclear Information System (INIS)

    Małek, Łukasz A.; Śpiewak, Mateusz; Kłopotowski, Mariusz; Petryka, Joanna; Mazurkiewicz, Łukasz; Kruk, Mariusz; Kępka, Cezary; Miśko, Jolanta; Rużyłło, Witold; Witkowski, Adam

    2012-01-01

    Background: Left ventricular hypertrophy (LVH) predisposes to larger infarct size, which may be underestimated by the left ventricular ejection fraction (LVEF) due to supranormal systolic performance often present in patients with LVH. The aim of the study was to compare infarct size and LVEF in patients with ST-segment elevation myocardial infarction (STEMI) and increased left ventricular mass on cardiac magnetic resonance (CMR). Methods: The study included unselected group of 52 patients (61 ± 11 years, 69% male) with first STEMI who had CMR after median 5 days from the onset of the event. Left ventricular hypertrophy (LVH) was defined as left ventricular mass index exceeding 95th percentile of references values for age and gender. Infarct size was assessed with means of late gadolinium enhancement (LGE). Results: LVH was found in 16 patients (31%). In comparison to the rest of the group, patients with LVH had higher absolute and relative infarct mass (p = 0.002 and p = 0.02, respectively). LVH was related to higher prevalence of microvascular obstruction and myocardial haemorrhage and higher number of LV segments with transmural necrosis (p = 0.02, p = 0.01 and p = 0.01, respectively). Despite marked difference in the infarct size between both studied subgroups there was no difference in LVEF and mean number of dysfunctional LV segments. Conclusions: Patients with LVH undergoing STEMI have larger infarct size underestimated by the LV systolic performance in comparison to patients without LVH.

  18. Left ventricular function during acute high-altitude exposure in a large group of healthy young Chinese men.

    Directory of Open Access Journals (Sweden)

    Mingyue Rao

    Full Text Available The purpose of this study was to observe left ventricular function during acute high-altitude exposure in a large group of healthy young males.A prospective trial was conducted in Szechwan and Tibet from June to August, 2012. By Doppler echocardiography, left ventricular function was examined in 139 healthy young Chinese men at sea level; within 24 hours after arrival in Lhasa, Tibet, at 3700 m; and on day 7 following an ascent to Yangbajing at 4400 m after 7 days of acclimatization at 3700 m. The resting oxygen saturation (SaO2, heart rate (HR and blood pressure (BP were also measured at the above mentioned three time points.Within 24 hours of arrival at 3700 m, the HR, ejection fraction (EF, fractional shortening (FS, stroke volume (SV, cardiac output (CO, and left ventricular (LV Tei index were significantly increased, but the LV end-systolic dimension (ESD, end-systolic volume (ESV, SaO2, E/A ratio, and ejection time (ET were significantly decreased compared to the baseline levels in all subjects. On day 7 at 4400 m, the SV and CO were significantly decreased; the EF and FS Tei were not decreased compared with the values at 3700 m; the HR was further elevated; and the SaO2, ESV, ESD, and ET were further reduced. Additionally, the E/A ratio was significantly increased on day 7 but was still lower than it was at low altitude.Upon acute high-altitude exposure, left ventricular systolic function was elevated with increased stroke volume, but diastolic function was decreased in healthy young males. With higher altitude exposure and prolonged acclimatization, the left ventricular systolic function was preserved with reduced stroke volume and improved diastolic function.

  19. Left ventricular mass in borderline hypertension assessed by echo cardiography

    International Nuclear Information System (INIS)

    Mezzasalma, L.; Ghione, S.; Palonebo, C.

    1989-01-01

    The relationship between clinical measurement of blood pressure (BP) and left ventricular hypertrophy in arterial hypertension appears to be weak in most studies. On the contrary, stronger correlations with target organ damage in general, and left ventricular hypertrophy in particular, have been reported for blood pressure measurements obtained by ambulatory monitoring; this finding may indicate a possible role for blood pressure response to naturally occurring stresses in determining left ventricular hypertrophy. Aim of this study was to investigate, in 18 patients with borderline arterial hypertension, the relationships between echocardiographically assessed left ventricular mass and, respectively, casual BP and BP responses to some standardized stress tests. Only three patients had a diastolic wall thickness of the interventricular septum and of the posterior wall ≥1.2 cm and none had a pathologically increased left ventricular mass index. The following statistically significant correlations were found: casual diastolic BP vs. left ventricular mass index (r=0.53, p<0.02), systolic BP response to bicycle exercise test vs. left ventricular mass index (r=0.55, p<0.05). Multiple regression analysis showed that almost fifty percent of the variability of left ventricular mass index could be predicted by these two BP measurements. These findings suggest that besides the chronically increased afterload, also the transient hypertensive responses to naturally occuring physical stresses may have a role in determining the extent of cardiac structural changes in borderline hypertensive patients. In addition, they indicate a direct relation between left ventricular mass and blood pressure levels also in borderline hypertension, as previously shown for established hypertension, despite the fact that left ventricular hypertrophy represents only an occasional finding in early stages of hypertension

  20. Evaluation of left ventricular ejection fraction by first pass radionuclide cardioangiography

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, T; Imai, Y; Kagawa, M; Hayashi, M; Kozuka, T [National Cardiovascular Center, Suita, Osaka (Japan)

    1980-02-01

    The left ventricular ejection fraction can be assessed by recording the passage of peripherally administered radioactive bolus through the heart which is first pass method. In this study, the accuracy and validity of first pass method were examined in the patients with cardiac catheterization. After sup(99m)Tc-HSA as a bolus was injected intravenouslly, the time-activity curve was recorded with a scintillation camera and online minicomputer system. The ejection fraction was calculated by the average of three cardiac cycles which corresponded to the left ventricular volume changes during each cardiac cycles. The results correlated well with those obtained by biplane cineangiography in the twenty patients without arrythmias (r = 0.89) and moreover, this technique was applied to the fifteen patients with atrial fibrillation such as mitral valvular diseases, congestive cardiomyopathy, Good correlation of the ejection fraction (r = 0.84) was obtained. The findings, however, demonstrated that the time-activity curve must be generated from the region of interest which fits the left ventricular blood pool precisely and must be corrected for the contribution arizing from noncardiac background structures (two matrix method). In conclusion, this noninvasive method appears particularly useful for serial evaluation of the patients with cardiac dysfunctions and would be available for the routine examination of ventricular functions.

  1. Left Ventricular Geometry In Nigerians With Type II Diabetes Mellitus ...

    African Journals Online (AJOL)

    Background: Left ventricular hypertrophy is independently associated with increased incidence of cardiovascular disease, cardiovascular and all cause mortality. In a relatively healthy hypertensive adult population, type II diabetes is associated with higher left ventricular mass, concentric left ventricular geometry and lower ...

  2. The overloaded right heart and ventricular interdependence.

    Science.gov (United States)

    Naeije, Robert; Badagliacca, Roberto

    2017-10-01

    The right and the left ventricle are interdependent as both structures are nested within the pericardium, have the septum in common and are encircled with common myocardial fibres. Therefore, right ventricular volume or pressure overloading affects left ventricular function, and this in turn may affect the right ventricle. In normal subjects at rest, right ventricular function has negligible interaction with left ventricular function. However, the right ventricle contributes significantly to the normal cardiac output response to exercise. In patients with right ventricular volume overload without pulmonary hypertension, left ventricular diastolic compliance is decreased and ejection fraction depressed but without intrinsic alteration in contractility. In patients with right ventricular pressure overload, left ventricular compliance is decreased with initial preservation of left ventricular ejection fraction, but with eventual left ventricular atrophic remodelling and altered systolic function. Breathing affects ventricular interdependence, in healthy subjects during exercise and in patients with lung diseases and altered respiratory system mechanics. Inspiration increases right ventricular volumes and decreases left ventricular volumes. Expiration decreases both right and left ventricular volumes. The presence of an intact pericardium enhances ventricular diastolic interdependence but has negligible effect on ventricular systolic interdependence. On the other hand, systolic interdependence is enhanced by a stiff right ventricular free wall, and decreased by a stiff septum. Recent imaging studies have shown that both diastolic and systolic ventricular interactions are negatively affected by right ventricular regional inhomogeneity and prolongation of contraction, which occur along with an increase in pulmonary artery pressure. The clinical relevance of these observations is being explored. Published on behalf of the European Society of Cardiology. All rights

  3. Left ventricular remodeling in preclinical experimental mitral regurgitation of dogs.

    Science.gov (United States)

    Dillon, A Ray; Dell'Italia, Louis J; Tillson, Michael; Killingsworth, Cheryl; Denney, Thomas; Hathcock, John; Botzman, Logan

    2012-03-01

    Dogs with experimental mitral regurgitation (MR) provide insights into the left ventricular remodeling in preclinical MR. The early preclinical left ventricular (LV) changes after mitral regurgitation represent progressive dysfunctional remodeling, in that no compensatory response returns the functional stroke volume (SV) to normal even as total SV increases. The gradual disease progression leads to mitral annulus stretch and enlargement of the regurgitant orifice, further increasing the regurgitant volume. Remodeling with loss of collagen weave and extracellular matrix (ECM) is accompanied by stretching and hypertrophy of the cross-sectional area and length of the cardiomyocyte. Isolated ventricular cardiomyocytes demonstrate dysfunction based on decreased cell shortening and reduced intracellular calcium transients before chamber enlargement or decreases in contractility in the whole heart can be clinically appreciated. The genetic response to increased end-diastolic pressure is down-regulation of genes associated with support of the collagen and ECM and up-regulation of genes associated with matrix remodeling. Experiments have not demonstrated any beneficial effects on remodeling from treatments that decrease afterload via blocking the renin-angiotensin system (RAS). Beta-1 receptor blockade and chymase inhibition have altered the progression of the LV remodeling and have supported cardiomyocyte function. The geometry of the LV during the remodeling provides insight into the importance of regional differences in responses to wall stress. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Detecting abnormalities in left ventricular function during exercise by respiratory measurement

    International Nuclear Information System (INIS)

    Koike, A.; Itoh, H.; Taniguchi, K.; Hiroe, M.

    1989-01-01

    The degree of exercise-induced cardiac dysfunction and its relation to the anaerobic threshold were evaluated in 23 patients with chronic heart disease. A symptom-limited exercise test was performed with a cycle ergometer with work rate increased by 1 W every 6 seconds. Left ventricular function, as reflected by ejection fraction, was continuously monitored with a computerized cadmium telluride detector after the intravenous injection of technetium-labeled red blood cells. The anaerobic threshold (mean, 727 ± 166 ml/min) was determined by the noninvasive measurement of respiratory gas exchange. As work rate rose, the left ventricular ejection fraction increased but reached a peak value at the anaerobic threshold and then fell below resting levels. Ejection fraction at rest, anaerobic threshold, and peak exercise were 41.4 ± 11.3%, 46.5 ± 12.0%, and 37.2 ± 11.0%, respectively. Stroke volume also increased from rest (54.6 ± 17.0 ml/beat) to the point of the anaerobic threshold (65.0 ± 21.2 ml/beat) and then decreased at peak exercise (52.4 ± 18.7 ml/beat). The slope of the plot of cardiac output versus work rate decreased above the anaerobic threshold. The anaerobic threshold occurred at the work rate above which left ventricular function decreased during exercise. Accurate determination of the anaerobic threshold provides an objective, noninvasive measure of the oxygen uptake above which exercise-induced deterioration in left ventricular function occurs in patients with chronic heart disease

  5. Echocardiographic left ventricular masses in distance runners and weight lifters

    Science.gov (United States)

    Longhurst, J. C.; Gonyea, W. J.; Mitchell, J. H.; Kelly, A. R.

    1980-01-01

    The relationships of different forms of exercise training to left ventricular mass and body mass are investigated by echocardiographic studies of weight lifters, long-distance runners, and comparatively sized untrained control subjects. Left ventricular mass determinations by the Penn convention reveal increased absolute left ventricular masses in long-distance runners and competitive weight lifters with respect to controls matched for age, body weight, and body surface area, and a significant correlation between ventricular mass and lean body mass. When normalized to lean body mass, the ventricular masses of distance runners are found to be significantly higher than those of the other groups, suggesting that dynamic training elevates left ventricular mass compared to static training and no training, while static training increases ventricular mass only to the extent that lean body mass is increased.

  6. Angiographic determination of the left-ventricular myocardial volume with the help of digital image processing

    International Nuclear Information System (INIS)

    Radtke, W.

    1981-01-01

    In this paper, digital image processing could for the first time be introduced as a new method to screen the myocardium in the left-ventricular angiocardiography. The method makes a reliable quantitative determination of the muscle mass of the left ventricle possible. (orig./MG) [de

  7. Comparison of Gated SPECT Myocardial Perfusion Imaging with Echocardiography for the Measurement of Left Ventricular Volumes and Ejection Fraction in Patients With Severe Heart Failure

    Science.gov (United States)

    Shojaeifard, Maryam; Ghaedian, Tahereh; Yaghoobi, Nahid; Malek, Hadi; Firoozabadi, Hasan; Bitarafan-Rajabi, Ahmad; Haghjoo, Majid; Amin, Ahmad; Azizian, Nasrin; Rastgou, Feridoon

    2015-01-01

    Background: Gated single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) is known as a feasible tool for the measurement of left ventricular ejection fraction (EF) and volumes, which are of great importance in the management and follow-up of patients with coronary artery diseases. However, considering the technical shortcomings of SPECT in the presence of perfusion defect, the accuracy of this method in heart failure patients is still controversial. Objectives: The aim of the present study was to compare the results from gated SPECT MPI with those from echocardiography in heart failure patients to compare echocardiographically-derived left ventricular dimension and function data to those from gated SPECT MPI in heart failure patients. Patients and Methods: Forty-one patients with severely reduced left ventricular systolic function (EF ≤ 35%) who were referred for gated SPECT MPI were prospectively enrolled. Quantification of EF, end-diastolic volume (EDV), and end-systolic volume (ESV) was performed by using quantitative gated spect (QGS) (QGS, version 0.4, May 2009) and emory cardiac toolbox (ECTb) (ECTb, revision 1.0, copyright 2007) software packages. EF, EDV, and ESV were also measured with two-dimensional echocardiography within 3 days after MPI. Results: A good correlation was found between echocardiographically-derived EF, EDV, and ESV and the values derived using QGS (r = 0.67, r = 0.78, and r = 0.80 for EF, EDV, and ESV, respectively; P echocardiography. ECTb-derived EDV was also significantly higher than the EDV measured with echocardiography and QGS. The highest correlation between echocardiography and gated SPECT MPI was found for mean values of ESV different. Conclusions: Gated SPECT MPI has a good correlation with echocardiography for the measurement of left ventricular EF, EDV, and ESV in patients with severe heart failure. However, the absolute values of these functional parameters from echocardiography and gated

  8. Left ventricular function in patients with ventricular arrhythmias and aortic valve disease

    International Nuclear Information System (INIS)

    Santinga, J.T.; Kirsh, M.M.; Brady, T.J.; Thrall, J.; Pitt, B.

    1983-01-01

    Forty patients having aortic valve replacement were evaluated preoperatively for ventricular arrhythmia and left ventricular ejection fraction. Arrhythmias were classified as complex or simple using the Lown criteria on the 24-hour ambulatory electrocardiogram; ejection fractions were determined by radionuclide gated blood pool analysis and contrast angiography. The ejection fractions determined by radionuclide angiography were 59.1 +/- 13.1% for 26 patients with simple or no ventricular arrhythmias, and 43.9 +/- 20.3% for 14 patients with complex ventricular arrhythmias (p less than 0.01). Ejection fractions determined by angiography, available for 31 patients, were also lower in patients with complex ventricular arrhythmias (61.1 +/- 16.3% versus 51.4 +/- 13.4%; p less than 0.05). Seven of 9 patients showing conduction abnormalities on the electrocardiogram had complex ventricular arrhythmias. Eight of 20 patients with aortic stenosis had complex ventricular arrhythmias, while 2 of 13 patients with aortic insufficiency had such arrhythmias. It is concluded that decreased left ventricular ejection fraction, intraventricular conduction abnormalities, and aortic stenosis are associated with an increased frequency of complex ventricular arrhythmias in patients with aortic valve disease

  9. Lung volumes, ventricular function and pulmonary arterial flow in children operated on for left-sided congenital diaphragmatic hernia: long-term results

    International Nuclear Information System (INIS)

    Abolmaali, Nasreddin; Koch, Arne; Goetzelt, Knut; Vogelberg, Christian; Hahn, Gabriele; Fitze, Guido

    2010-01-01

    To compare MRI-based functional pulmonary and cardiac measurements in the long-term follow-up of children operated on for left-sided congenital diaphragmatic hernia (CDH) with age- and body size-matched healthy controls. Twelve children who received immediate postnatal surgery for closure of isolated left-sided CDH were included and received basic medical examinations, pulmonary function testing and echocardiography. MRI included measurement of lung volume, ventricular function assessment and velocity-encoded imaging of the pulmonary arteries and was compared with the data for 12 healthy children matched for age and body size. While patients' clinical test results were not suspicious, comparison between the MRI data for patients and those for healthy controls revealed significant differences. In patients, the volumes of the left lungs were increased and the tidal volume was larger on the right side. While the stroke volumes of both ventricles were reduced, heart rate and ejection fraction were increased. Flow, acceleration time and cross-sectional area of the left pulmonary artery were reduced. Functional MRI detected pulmonary and cardiac findings in the late follow-up of CDH children which may be missed by standard clinical methods and might be relevant for decisions regarding late outcome and treatment. (orig.)

  10. Lung volumes, ventricular function and pulmonary arterial flow in children operated on for left-sided congenital diaphragmatic hernia: long-term results

    Energy Technology Data Exchange (ETDEWEB)

    Abolmaali, Nasreddin; Koch, Arne [Dresden University of Technology, OncoRay - Molecular and Biological Imaging, Medical Faculty Carl Gustav Carus, Dresden (Germany); Goetzelt, Knut; Vogelberg, Christian [University Clinics Carl Gustav Carus, Dresden University of Technology, Clinic and Policlinic for Pediatrics - Pediatric Pulmonology, Dresden (Germany); Hahn, Gabriele [University Clinics Carl Gustav Carus, Dresden University of Technology, Institute and Policlinic for Radiology - Pediatric Radiology, Dresden (Germany); Fitze, Guido [University Clinics Carl Gustav Carus, Dresden University of Technology, Clinic and Policlinic for Pediatric Surgery, Dresden (Germany)

    2010-07-15

    To compare MRI-based functional pulmonary and cardiac measurements in the long-term follow-up of children operated on for left-sided congenital diaphragmatic hernia (CDH) with age- and body size-matched healthy controls. Twelve children who received immediate postnatal surgery for closure of isolated left-sided CDH were included and received basic medical examinations, pulmonary function testing and echocardiography. MRI included measurement of lung volume, ventricular function assessment and velocity-encoded imaging of the pulmonary arteries and was compared with the data for 12 healthy children matched for age and body size. While patients' clinical test results were not suspicious, comparison between the MRI data for patients and those for healthy controls revealed significant differences. In patients, the volumes of the left lungs were increased and the tidal volume was larger on the right side. While the stroke volumes of both ventricles were reduced, heart rate and ejection fraction were increased. Flow, acceleration time and cross-sectional area of the left pulmonary artery were reduced. Functional MRI detected pulmonary and cardiac findings in the late follow-up of CDH children which may be missed by standard clinical methods and might be relevant for decisions regarding late outcome and treatment. (orig.)

  11. Lung volumes, ventricular function and pulmonary arterial flow in children operated on for left-sided congenital diaphragmatic hernia: long-term results.

    Science.gov (United States)

    Abolmaali, Nasreddin; Koch, Arne; Götzelt, Knut; Hahn, Gabriele; Fitze, Guido; Vogelberg, Christian

    2010-07-01

    To compare MRI-based functional pulmonary and cardiac measurements in the long-term follow-up of children operated on for left-sided congenital diaphragmatic hernia (CDH) with age- and body size-matched healthy controls. Twelve children who received immediate postnatal surgery for closure of isolated left-sided CDH were included and received basic medical examinations, pulmonary function testing and echocardiography. MRI included measurement of lung volume, ventricular function assessment and velocity-encoded imaging of the pulmonary arteries and was compared with the data for 12 healthy children matched for age and body size. While patients' clinical test results were not suspicious, comparison between the MRI data for patients and those for healthy controls revealed significant differences. In patients, the volumes of the left lungs were increased and the tidal volume was larger on the right side. While the stroke volumes of both ventricles were reduced, heart rate and ejection fraction were increased. Flow, acceleration time and cross-sectional area of the left pulmonary artery were reduced. Functional MRI detected pulmonary and cardiac findings in the late follow-up of CDH children which may be missed by standard clinical methods and might be relevant for decisions regarding late outcome and treatment.

  12. Central-Approach Surgical Repair of Coarctation of the Aorta with a Back-up Left Ventricular Assist Device for an Infant Presenting with Severe Left Ventricular Dysfunction

    Directory of Open Access Journals (Sweden)

    Tae Hoon Kim

    2015-12-01

    Full Text Available A two-month-old infant presented with coarctation of the aorta, severe left ventricular dysfunction, and moderate to severe mitral regurgitation. Through median sternotomy, the aortic arch was repaired under cardiopulmonary bypass and regional cerebral perfusion. The patient was postoperatively supported with a left ventricular assist device for five days. Left ventricular function gradually improved, eventually recovering with the concomitant regression of mitral regurgitation. Prompt surgical repair of coarctation of the aorta is indicated for patients with severe left ventricular dysfunction. A central approach for surgical repair with a back-up left ventricular assist device is a safe and effective treatment strategy for these patients.

  13. Central-Approach Surgical Repair of Coarctation of the Aorta with a Back-up Left Ventricular Assist Device for an Infant Presenting with Severe Left Ventricular Dysfunction.

    Science.gov (United States)

    Kim, Tae Hoon; Shin, Yu Rim; Kim, Young Sam; Kim, Do Jung; Kim, Hyohyun; Shin, Hong Ju; Htut, Aung Thein; Park, Han Ki

    2015-12-01

    A two-month-old infant presented with coarctation of the aorta, severe left ventricular dysfunction, and moderate to severe mitral regurgitation. Through median sternotomy, the aortic arch was repaired under cardiopulmonary bypass and regional cerebral perfusion. The patient was postoperatively supported with a left ventricular assist device for five days. Left ventricular function gradually improved, eventually recovering with the concomitant regression of mitral regurgitation. Prompt surgical repair of coarctation of the aorta is indicated for patients with severe left ventricular dysfunction. A central approach for surgical repair with a back-up left ventricular assist device is a safe and effective treatment strategy for these patients.

  14. Low tidal volume ventilation ameliorates left ventricular dysfunction in mechanically ventilated rats following LPS-induced lung injury.

    Science.gov (United States)

    Cherpanath, Thomas G V; Smeding, Lonneke; Hirsch, Alexander; Lagrand, Wim K; Schultz, Marcus J; Groeneveld, A B Johan

    2015-10-07

    High tidal volume ventilation has shown to cause ventilator-induced lung injury (VILI), possibly contributing to concomitant extrapulmonary organ dysfunction. The present study examined whether left ventricular (LV) function is dependent on tidal volume size and whether this effect is augmented during lipopolysaccharide(LPS)-induced lung injury. Twenty male Wistar rats were sedated, paralyzed and then randomized in four groups receiving mechanical ventilation with tidal volumes of 6 ml/kg or 19 ml/kg with or without intrapulmonary administration of LPS. A conductance catheter was placed in the left ventricle to generate pressure-volume loops, which were also obtained within a few seconds of vena cava occlusion to obtain relatively load-independent LV systolic and diastolic function parameters. The end-systolic elastance / effective arterial elastance (Ees/Ea) ratio was used as the primary parameter of LV systolic function with the end-diastolic elastance (Eed) as primary LV diastolic function. Ees/Ea decreased over time in rats receiving LPS (p = 0.045) and high tidal volume ventilation (p = 0.007), with a lower Ees/Ea in the rats with high tidal volume ventilation plus LPS compared to the other groups (p tidal volume ventilation without LPS (p = 0.223). A significant interaction (p tidal ventilation and LPS for Ees/Ea and Eed, and all rats receiving high tidal volume ventilation plus LPS died before the end of the experiment. Low tidal volume ventilation ameliorated LV systolic and diastolic dysfunction while preventing death following LPS-induced lung injury in mechanically ventilated rats. Our data advocates the use of low tidal volumes, not only to avoid VILI, but to avert ventilator-induced myocardial dysfunction as well.

  15. Calculation of left ventricular volumes and ejection fraction from dynamic cardiac-gated 15O-water PET/CT: 5D-PET

    OpenAIRE

    Jonny Nordström; Tanja Kero; Hendrik Johannes Harms; Charles Widström; Frank A. Flachskampf; Jens Sörensen; Mark Lubberink

    2017-01-01

    BACKGROUND: Quantitative measurement of myocardial blood flow (MBF) is of increasing interest in the clinical assessment of patients with suspected coronary artery disease (CAD). (15)O-water positron emission tomography (PET) is considered the gold standard for non-invasive MBF measurements. However, calculation of left ventricular (LV) volumes and ejection fraction (EF) is not possible from standard (15)O-water uptake images. The purpose of the present work was to investigate the possibility...

  16. ECG-gated scintillation probe measurement of left ventricular function

    International Nuclear Information System (INIS)

    Bacharach, S.L.; Green, M.V.; Borer, J.S.; Ostrow, H.G.; Redwood, D.R.; Johnston, G.S.

    1977-01-01

    A nonimaging, ECG-gated scintillation-probe system is described that permits real-time quantification, at high temporal resolution, of the time variation of left ventricular (LV) volume over a complete, average cardiac cycle. Linearity between counting rate and volume, probe positioning, and background correction were investigated for both cylindrically collimated (CC) and parallel-hole-collimated (PC) detectors. In 53 patient studies, results obtained with these probes were compared with results obtained from an ECG-gated gamma camera system (CS) with high temporal resolution. Time-activity curves obtained by all three devices were essentially identical in shape (for CC against CS, r = 0.93; for PC against CS, r = 0.98) and in intracycle timing. Left-ventricular ejection fractions obtained with the probes showed workable agreement with the camera: for CC against CS, r = 0.85 (N = 31); for PC against CS, r = 0.90 (N = 21). When LV background is removed as a source of error, the correlation between (PC) probe and camera is improved (r = 0.95, N = 21). This suggests that the portable probe system be used in circumstances where exact knowledge of LV background is minimally important--e.g., continuous bedside monitoring of changes in LV function

  17. LEFT VENTRICULAR ROTATION, TWIST AND UNTWIST: PHYSIOLOGICAL ROLE AND CLINICAL RELEVANCE

    Directory of Open Access Journals (Sweden)

    E. N. Pavlyukova

    2015-09-01

    Full Text Available The helical ventricular myocardial band of Torrent-Guasp is a new concept, which provides strong grounds for reconciliation of some important aspects in cardiovascular medicine. Oblique fiber orientation provides left ventricular rotation, which in addition to radial thickening and longitudinal shortening, is predicted as an essential component of the effective left ventricular pumping. Left ventricular rotation can be measured in clinical practice noninvasively using echocardiography and this provides new opportunities for the assessment of different aspects of left ventricular mechanical function.

  18. Associations of Blood Pressure Dipping Patterns With Left Ventricular Mass and Left Ventricular Hypertrophy in Blacks: The Jackson Heart Study.

    Science.gov (United States)

    Abdalla, Marwah; Caughey, Melissa C; Tanner, Rikki M; Booth, John N; Diaz, Keith M; Anstey, D Edmund; Sims, Mario; Ravenell, Joseph; Muntner, Paul; Viera, Anthony J; Shimbo, Daichi

    2017-04-05

    Abnormal diurnal blood pressure (BP), including nondipping patterns, assessed using ambulatory BP monitoring, have been associated with increased cardiovascular risk among white and Asian adults. We examined the associations of BP dipping patterns (dipping, nondipping, and reverse dipping) with cardiovascular target organ damage (left ventricular mass index and left ventricular hypertrophy), among participants from the Jackson Heart Study, an exclusively black population-based cohort. Analyses included 1015 participants who completed ambulatory BP monitoring and had echocardiography data from the baseline visit. Participants were categorized based on the nighttime to daytime systolic BP ratio into 3 patterns: dipping pattern (≤0.90), nondipping pattern (>0.90 to ≤1.00), and reverse dipping pattern (>1.00). The prevalence of dipping, nondipping, and reverse dipping patterns was 33.6%, 48.2%, and 18.2%, respectively. In a fully adjusted model, which included antihypertensive medication use and clinic and daytime systolic BP, the mean differences in left ventricular mass index between reverse dipping pattern versus dipping pattern was 8.3±2.1 g/m 2 ( P pattern versus dipping pattern was -1.0±1.6 g/m 2 ( P =0.536). Compared with participants with a dipping pattern, the prevalence ratio for having left ventricular hypertrophy was 1.65 (95% CI, 1.05-2.58) and 0.96 (95% CI, 0.63-1.97) for those with a reverse dipping pattern and nondipping pattern, respectively. In this population-based study of blacks, a reverse dipping pattern was associated with increased left ventricular mass index and a higher prevalence of left ventricular hypertrophy. Identification of a reverse dipping pattern on ambulatory BP monitoring may help identify black at increased risk for cardiovascular target organ damage. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  19. Left ventricular hypertrophy: virtuous intentions, malign consequences.

    Science.gov (United States)

    Pokharel, Saraswati; Sharma, Umesh C; Pinto, Yigal M

    2003-06-01

    Left ventricular hypertrophy (LVH) is currently the focus of intense cardiovascular research, with the resultant rapid evolution of novel concepts relating to its exceedingly complex pathophysiology. In addition to the alterations in signal transduction and disturbances in Ca(2+) homeostasis, there are structural changes in myofilaments, disorganization of the cytoskeletal framework and increased collagen synthesis. LVH is associated with progressive left ventricular remodeling that culminates to heart failure. The modern treatment of left ventricular hypertrophy is now largely based on the hypothesis that neuroendocrine activation is important in the progression of the disease and inhibition of neurohormones is likely to have long-term benefit with regard to morbidity and mortality. Drugs specifically designed to unload the left ventricle, such as diuretics and vasodilators, appears to be less effective in reducing LV mass and improving prognosis. Thus, the evolution of treatment for LVH itself has provided much enlightenment for our understanding of the fundamental biology of the disorder.

  20. Effect of Left Ventricular Outflow Tract Obstruction on Left Atrial Mechanics in Hypertrophic Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Lynne K. Williams

    2015-01-01

    Full Text Available Left atrial (LA volumes are known to be increased in hypertrophic cardiomyopathy (HCM and are a predictor of adverse outcome. In addition, LA function is impaired and is presumed to be due to left ventricular (LV diastolic dysfunction as a result of hypertrophy and myocardial fibrosis. In the current study, we assess the incremental effect of outflow tract obstruction (and concomitant mitral regurgitation on LA function as assessed by LA strain. Patients with HCM (50 obstructive, 50 nonobstructive were compared to 50 normal controls. A subset of obstructive patients who had undergone septal myectomy was also studied. Utilising feature-tracking software applied to cardiovascular magnetic resonance images, LA volumes and functional parameters were calculated. LA volumes were significantly elevated and LA ejection fraction and strain were significantly reduced in patients with HCM compared with controls and were significantly more affected in patients with obstruction. LA volumes and function were significantly improved after septal myectomy. LVOT obstruction and mitral regurgitation appear to further impair LA mechanics. Septal myectomy results in a significant reduction in LA volumes, paralleled by an improvement in function.

  1. Effects of Thyroid Hormone on Left Ventricular Volume and Function in Hyperthyroidism

    International Nuclear Information System (INIS)

    Lee, Myung Chul; Koh, Chang Soon

    1983-01-01

    The purpose of this study is to investigate the effects of thyroid hormone on the left ventricular (LV) volume and function in man with untreated hyperthyroidism and to determine the effects of successful therapy for thyrotoxicosis on the ventricular pathophysiology. In the present study, equilibrium ralhianuclide cardiac angiography was performed and LV volume index, ejection phase indexes of LV performance, serum thyroid hormone levels and other hemodynamic parameters were measured in 28 normal subjects and 39 patients with hyperthyroidism before treatment and again every 4 weeks for the first 2 months after the initiation of effective therapy. The result obtained were as follows; 1) In the untreated hyperthyroid state heart rate, blood volume, cardiac index and stroke volume index (97±14 beats/min, 73.5±11.8 ml/kg, 6.9±1.4 l/min/m2 and 77.6±13.8 ml/m2, respectively) were increased significantly compared to those in normal control (74±12 beats/min, 65.6±14.8 ml/kg, 3.8±1.2 l/min/m2 and 56.6±13.2 ml/m2 respectively). (Mean±SD). 2) There was a significant increase in LV end-diastolic volume index in patients with hyperthyroidism (30.5±7.5 for hyperthyroid group compared to a normal control of 22.2±6.5; P<0.001), whereas end-systolic volume index remained unchanged 9.6±3.6 and 8.8±3.3 respectively. 3) In patients with hyperthyroidism, LV ejection fraction was 70.0±5.6%, fractional shortening 32.9±5.1%, mean velocity of circumferential fiber shortening (mean Vcf) 1.34±0.31 circ/sec and maximum ejection rate 3.47±0.80. All the ejection phase indexes were significantly greater than those in normal control (65.2±5.7%, 28.8±3.2%, 0.88±0.37 circ/sec and 2.27±0.50, respectively; p<0.001). 4) Effective therapy produced significant decrease in all the values of serum thyroid hormone concenrations (p<0.001), hemodynamic parameters (p<0.001), end-diastolic volume index (p<0.01) and ejection phase indexes of LV contractility in patients with hyperthyroidism

  2. Left ventricular volume analysis as a basic tool to describe cardiac function.

    Science.gov (United States)

    Kerkhof, Peter L M; Kuznetsova, Tatiana; Ali, Rania; Handly, Neal

    2018-03-01

    The heart is often regarded as a compression pump. Therefore, determination of pressure and volume is essential for cardiac function analysis. Traditionally, ventricular performance was described in terms of the Starling curve, i.e., output related to input. This view is based on two variables (namely, stroke volume and end-diastolic volume), often studied in the isolated (i.e., denervated) heart, and has dominated the interpretation of cardiac mechanics over the last century. The ratio of the prevailing coordinates within that paradigm is termed ejection fraction (EF), which is the popular metric routinely used in the clinic. Here we present an insightful alternative approach while describing volume regulation by relating end-systolic volume (ESV) to end-diastolic volume. This route obviates the undesired use of metrics derived from differences or ratios, as employed in previous models. We illustrate basic principles concerning ventricular volume regulation by data obtained from intact animal experiments and collected in healthy humans. Special attention is given to sex-specific differences. The method can be applied to the dynamics of a single heart and to an ensemble of individuals. Group analysis allows for stratification regarding sex, age, medication, and additional clinically relevant covariates. A straightforward procedure derives the relationship between EF and ESV and describes myocardial oxygen consumption in terms of ESV. This representation enhances insight and reduces the impact of the metric EF, in favor of the end-systolic elastance concept advanced 4 decades ago.

  3. Determination of left ventricular function parameters and myocardial mass: comparison of MRI and EBT

    International Nuclear Information System (INIS)

    Kivelitz, D.E.; Enzweiler, C.N.H.; Wiese, T.H.; Lembcke, A.; Taupitz, M.; Hamm, B.; Borges, A.; Zytowski, M.

    2000-01-01

    Purpose: Comparative volumetric assessment of the left ventricle by magnetic resonance imaging (MRI) and electron beam tomography (EBT) in patients with ischemic and dilated cardiac disease. Methods: Thirty-two patients underwent cine MRI and EBT in the multislice mode. All studies were triggered to the ECG. Left ventricular ejection fraction (EF), enddiastolic (EDV) and endsystolic volume (ESV), and myocardial mass (MM) were determined by 3D-volumetry by MRI and EBT and results were compared. Results: The correlation between MRI and EBT for EF, EDV, ESV, and MM were r=0.86, r=0.95, r=0.95, and r=0.93, respectively. Conclusions: There is an excellent correlation between MRI and EBT in determining left-ventricular parameters. Both methods are suitable for volumetric assessment of the left ventricie. (orig.) [de

  4. Neuromodulation therapy does not influence blood flow distribution or left-ventricular dynamics during acute myocardial ischemia.

    Science.gov (United States)

    Kingma, J G; Linderoth, B; Ardell, J L; Armour, J A; DeJongste, M J; Foreman, R D

    2001-08-13

    Electrical stimulation of the dorsal aspect of the upper thoracic spinal cord is used increasingly to treat patients with angina pectoris refractory to conventional therapeutic strategies. The purpose of this study was to determine whether spinal cord stimulation (SCS) in dogs affects regional myocardial blood flow and left-ventricular (LV) function before and during transient obstruction of the left anterior descending coronary artery (LAD). In anesthetized dogs, regional myocardial blood flow distribution was determined using radiolabeled microspheres and left-ventricular function was measured by impedance-derived pressure-volume loops. SCS was accomplished by stimulating the dorsal T1-T2 segments of the spinal cord using epidural bipolar electrodes at 90% of motor threshold (MT) (50 Hz, 0.2-ms duration). Effects of 5-min SCS were assessed under basal conditions and during 4-min occlusion of the LAD. SCS alone evoked no change in regional myocardial blood flow or cardiovascular indices. Transient LAD occlusion significantly diminished blood flow within ischemic, but not in non-ischemic myocardial tissue. Left ventricular pressure-volume loops were shifted rightward during LAD occlusion. Cardiac indices were altered similarly during LAD occlusion and concurrent SCS. SCS does not influence the distribution of blood flow within the non-ischemic or ischemic myocardium. Nor does it modify LV pressure-volume dynamics in the anesthetized experimental preparation.

  5. Comparison of 16-frame and 8-frame gated SPET imaging for determination of left ventricular volumes and ejection fraction

    International Nuclear Information System (INIS)

    Navare, Sachin M.; Liu, Yi-Hwa; Wackers, Frans J.T.

    2003-01-01

    Electrocardiographic (ECG) gated single-photon emission tomography (SPET) allows for simultaneous assessment of myocardial perfusion and left ventricular (LV) function. Presently 8-frame per cardiac cycle ECG gating of SPET images is standard. The aim of this study was to compare the effect of 8-frame and 16-frame gated SPET on measurements of LV volumes and to evaluate the effects of the presence of myocardial perfusion defects and of radiotracer dose administered on the calculation of LV volumes. A total of 86 patients underwent technetium-99m SPET myocardial perfusion imaging using 16-frame per cardiac cycle acquisition. Eight-frame gated SPET images were generated by summation of contiguous frames. Left ventricular end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were calculated from the 16-frame and 8-frame data sets. The patients were divided into groups according to the administered dose of the radiotracer and the size of the perfusion defect. Results. Sixteen frame per cardiac cycle acquisition resulted in significantly larger EDV (122±72 ml vs 115±68 ml, P<0.0001), smaller ESV (64±58.6 ml vs 67.6±59.5 ml, P<0.0001), and higher LVEF (55.3%±18% vs 49%±17.4%, P<0.0001) as compared to 8-frame SPET imaging. This effect was seen regardless of whether a high or a low dose was administered and whether or not significant perfusion defects were present. This study shows that EDV, ESV and LVEF determined by 16-frame gated SPET are significantly different from those determined by 8-frame gated SPET. The radiotracer dose and perfusion defects do not affect estimation of LV parameters by 16-frame gated SPET. (orig.)

  6. Reference absolute and indexed values for left and right ventricular volume, function and mass from cardiac computed tomography

    International Nuclear Information System (INIS)

    Stojanovska, Jadranka; Prasitdumrong, Hutsaya; Patel, Smita; Sundaram, Baskaran; Gross, Barry H.; Yilmaz, Zeynep N.; Kazerooni, Ella A.

    2014-01-01

    Left ventricular (LV) and right ventricular (RV) volumetric and functional parameters are important biomarkers for morbidity and mortality in patients with heart failure. To retrospectively determine reference mean values of LV and RV volume, function and mass normalised by age, gender and body surface area (BSA) from retrospectively electrocardiographically gated 64-slice cardiac computed tomography (CCT) by using automated analysis software in healthy adults. The study was approved by the institutional review board with a waiver of informed consent. Seventy-four healthy subjects (49% female, mean age 49.6±11) free of hypertension and hypercholesterolaemia with a normal CCT formed the study population. Analyses of LV and RV volume (end-diastolic, end-systolic and stroke volumes), function (ejection fraction), LV mass and inter-rater reproducibility were performed with commercially available analysis software capable of automated contour detection. General linear model analysis was performed to assess statistical significance by age group after adjustment for gender and BSA. Bland–Altman analysis assessed the inter-rater agreement. The reference range for LV and RV volume, function, and LV mass was normalised to age, gender and BSA. Statistically significant differences were noted between genders in both LV mass and RV volume (P-value<0.0001). Age, in concert with gender, was associated with significant differences in RV end-diastolic volume and LV ejection fraction (P-values 0.027 and 0.03). Bland–Altman analysis showed acceptable limits of agreement (±1.5% for ejection fraction) without systematic error. LV and RV volume, function and mass normalised to age, gender and BSA can be reported from CCT datasets, providing additional information important for patient management.

  7. A servo-controlled canine model of stable severe ischemic left ventricular failure.

    Science.gov (United States)

    Wagner, Richard L; Hood, William B; Howland, Peter A

    2009-12-01

    Reversible left ventricular failure was produced in conscious dogs by compromise of the coronary circulation. In animals with prior left anterior descending coronary artery occlusion, mean left atrial pressure (LAP) was incorporated into an automatic feedback control system used to inflate a balloon cuff on the circumflex (Cfx) coronary artery. The system could produce stable increases in LAP to 15-20 mm Hg. The dominating system transfer function was the ratio of LAP to balloon volume (BV), which was characterized by a fixed delay (5 s), with LAP/BV = (8e(-jomegatau ))/(0.02 + jomega). The system was stabilized by a phase lead network to reduce oscillations of LAP. A total of seven experiments were conducted in three dogs, and testing of inotropic agents was possible in three experiments under stable conditions with the pump off after an hour or more of operation. Problems encountered were 0.003-0.008 Hz oscillations in LAP in three experiments, which could usually be controlled by reducing the system gain. Late stage ventricular fibrillation occurred in all three animals, but defibrillation was easily accomplished after deflating the Cfx balloon. This system produces reversible left ventricular failure solely due to ischemia, thus closely simulating clinical heart failure due to coronary insufficiency.

  8. Evaluation of diastolic phase by left ventricular volume curve using s2-gated equilibrium method among radioisotope angiography

    International Nuclear Information System (INIS)

    Watanabe, Yoshirou; Sakai, Akira; Inada, Mitsuo; Shiraishi, Tomokuni; Kobayashi, Akitoshi

    1982-01-01

    S2-gated (the second heart sound) method was designed by authors. In 6 normal subjects and 16 patients (old myocardial infarction 12 cases, hypertension 2 cases and aortic regurgitation 2 cases), radioisotope (RI) angiography using S2-gated equilibrium method was performed. In RI angiography, sup(99m)Tc-human serum albumin (HSA) 555MBq (15mCi) as tracer, PDP11/34 as minicomputer and PCG/ECG symchromizer (Metro Inst.) were used. Then left ventricular (LV) volume curve by S2-gated and electrocardiogram (ECG) R wave-gated method were obtained. Using LV volume curve, left ventricular ejection fraction (EF), mean ejection rate (mER, s -1 ), mean filling rate (mFR, -1 ) and rapid filling fraction (RFF) were calculated. mFR indicated mean filling rate during rapid filling phase. RFF was defined as the filling fraction during rapid filling phase among stroke volume. S2-gated method was reliable in evaluation of early diastolic phase, compared with ECG-gated method. There was the difference between RFF in normal group and myocardial infarction (MI) group (p < 0.005). RFF in 2 groups were correlated with EF (r = 0.82, p < 0.01). RFF was useful in evaluating MI cases who had normal EF values. The comparison with mER by ECG-gated and mFR by S2-gated was useful in evaluating MI cases who had normal mER values. mFR was remarkably lower than mER in MI group, but was equal to mER in normal group approximately. In conclusion, the evaluation using RFF and mFR by S2-gated method was useful in MI cases who had normal systolic phase indices. (author)

  9. Quantification of left ventricular volumes from cardiac cine MRI using active contour model combined with gradient vector flow

    International Nuclear Information System (INIS)

    Tanki, Nobuyoshi; Murase, Kenya; Kumashiro, Masayuki; Momoi, Risa; Yang, Xiaomei; Tabuchi, Takashi; Nagayama, Masako; Watanabe, Yuji

    2005-01-01

    We investigated the feasibility of combining the active contour model with gradient vector flow (Snakes-GVF) to estimate left ventricular (LV) volumes from cardiac cine magnetic resonance imaging (MRI). MRI data were acquired from 27 patients, including 14 adults (9 men, 5 women, 55.0±23.3 years) and 13 children (10 boys, 3 girls, 2.7±2.1 years) using Gyroscan Intera (1.5 Tesla, Philips Medical Systems). LV volumes were calculated by adding the areas surrounded by the contour extracted by Snakes-GVF and compared with volumes estimated by manual tracing. Those estimated by Snakes-GVF [y (mL)] correlated well with those estimated by manual tracing [x (mL)]. In adult cases, the regression equation and correlation coefficient were y=1.008x-0.517 and 0.996, respectively. In pediatric cases, they were y=1.174x-2.542 and 0.992, respectively. In conclusion, Snakes-GVF is a powerful and useful tool for quantifying LV volumes using cardiac MRI. (author)

  10. Assessment of cardiac performance with quantitative radionuclide angiocardiography: sequential left ventricular ejection fraction, normalized left ventricular ejection rate, and regional wall motion

    International Nuclear Information System (INIS)

    Marshall, R.C.; Berger, H.J.; Costin, J.C.; Freedman, G.S.; Wolberg, J.; Cohen, L.S.; Gotischalk, A.; Zaret, B.L.

    1977-01-01

    Sequential quantitative first pass radionuclide angiocardiograms (RA) were used to measure left ventricular ejection fraction (LVEF) and left ventricular ejection rate (LVER), and to assess regional wall motion (RWM) in the anterior (ANT) and left anterior oblique (LAO) positions. Studies were obtained with a computerized multicrystal scintillation camera suitable for acquiring high count-rate data. Background was determined in a new fashion by selecting frames temporally from the left ventricular region of interest time-activity curve. A ''representative'' cardiac cycle was formed by summing together counts over three to six cardiac cycles. From this background corrected, high count-rate ''representative''cardiac cycle, LVEF, LVER, and RWM were determined. In 22 patients with normal sinus rhythm in the absence of significant valvular regurgitation, RA LVEF correlated well with that measured by contrast angiography (r = 0.95). LVER correlated well with LVEF measured at contrast angiography (r = 0.90) and allowed complete separation of those with normal (LVER = 3.4 +- 0.17 sec -1 ) and abnormal (LVER = 1.22 +- 0.11 sec -1 ) (P < 0.001) left ventricular performance. This separation was independent of background. Isoproterenol infusion in five normal subjects caused LVER to increase by 81 +- 17% while LVEF increased by 10 +- 2.0%. RWM was correctly defined in 21/22 patients and 89% of left ventricular segments with abnormal wall motion

  11. Value of transient dilation of the left ventricular cavity on stress thallium scintigraphy

    International Nuclear Information System (INIS)

    Sugihara, Hiroki; Shiga, Kouji; Umamoto, Ikuo

    1991-01-01

    This study was undertaken to evaluate the value of transient dilation of the left ventricular cavity on stress thallium scintigraphy in 80 patients with ischemic heart disease (IHD) and 50 with hypertrophic cardiomyopathy (HCM). Twenty persons without either coronary artery stenosis or heart disease were served as controls. Areas surrounded by maximum count points on the line of each 10deg on the short axis slice through the mid-cavity of the left ventricle were obtained at 10 minutes and at 3 hours after exercise. Transient dilation index (TDI) was obtained by dividing the area on early image by that on delayed image. TDI was significantly higher in patients with two or three vessel disease in the IHD group than the control group. High TDI was observed in 8% for one vessel disease, 40% for two vessel disease, and 80% for three vessel disease, contributing to the detection of multivessel IHD. In the HCM group of 80 patients, 24 (48%) had high TDI which was frequently associated with a history of chest pain and positive ECG findings at exercise. When these 24 HCM patients underwent exercise blood pool scintiscanning, left ventricular enddiastolic volume was similar before and at 10 minutes after exercise. These findings suggest that transient dilation of the left ventricular cavity after exercise may reflect subendocardial ischemia in both IHD and HCM. TDI would become a useful indicator for transient dilation of the left ventricular cavity. (N.K.)

  12. Evaluation of left ventricular function and volume in patients with dilated cardiomyopathy: Gated myocardial single-photon emission tomography (SPECT) versus echocardiography

    International Nuclear Information System (INIS)

    Berk, Fatma; Isgoren, S.; Demir, H.; Kozdag, G.; Ural, D.; Komsuoglu, B.

    2005-01-01

    Left ventricular function, volumes and regional wall motion provide valuable diagnostic information and are of long-term prognostic importance in patients with dilated cardiomyopathy (DCM). This study was designed to compare the effectiveness of 2D-echocardiography and gated single-photon emission tomography (SPECT) for evaluation of these parameters in patients with DCM. Gated SPECT and 2D-echocardiography were performed in 33 patients having DCM. Gated SPECT data, including left ventricular ejection fraction (LVEF), were processed using an automated algorithm. Standard technique was used for 2D-echocardiography. Regional wall motion was evaluated using both modalities and was scored by two independent observers using a 16-sement model with a 5-point scoring system. The overall agreement between the two imaging modalities for the assessment of regional wall motion was 56% (298/528 segments). With gated SPECT, LEVF, end-diastolic volume (EDV), and end-diastolic volume (EDV), and end-systolic volume (ESV) were 27+-9%, 217+-73mL, respectively, and 30.8%, 195+-58mL and, 137+-48 mL with echocardiography. The correlation between gated SPECT and 2-D-echocardiography was good (r=0.76, P<0.01) for the assessment of LVEF. The correlation for EDV and ESV were also good, but with wider limits of agreement (r=0.72, P<0.01 and r=0.73, P<0.01, respectively) and significantly higher values were obtained with gated SPECT (P<0.01). Gated SPECT and 2D-echocardiography correlate well for the assessment of LV function and LV volumes. Like 2D-echocardiography, gated SPECT provides reliable information about LV function and dimension with the additional advantage of perfusion data. (author)

  13. Analysis of the relationship between myocardial viability and regional left ventricular wall motion

    International Nuclear Information System (INIS)

    Furutani, Yuhji; Ozaki, Masaharu; Yamamoto, Takeshi; Sato, Shinichi; Saiki, Atsushi; Kusukawa, Reizo

    1993-01-01

    Myocardial viability was determined by using postsystolic shortening (PSS) as an index, as obtained by cardiac blood pool scintigraphy with Tc-99m HSA. The findings were compared with those of thallium-201 myocardial SPECT. The study population was comparised of 41 patients with single blood vessel disease in the left anterior descending artery (34 with old myocardial infarction and 7 with effort angina pectoris). Left ventricular area was divided into 6 segments, and global and regional left ventricular blood volume curves were obtained. Delayed end-systole was the most common in the apex (41%), followed by the upper septum (37%) and lower septum (10%). PSS resulting from delayed end-systole was seen in 36 areas. PSS/end-diastolic volume (EDV) and PSS/systolic volume (SV) were obtained by adjusting end-diastolic and stroke counts, respectively. Thallium-201 myocardial SPECT images were divided into 5 segments to obtain defect score (DS) for visual Tl uptake. Both PSS/EDV and PSS/SV were greater in association with more delayed end-systole, greater DS, and lower reginal ejection fraction. Areas showing greater PSS were associated with less myocardial viability, as observed on Tl myocardial SPECT images. Thus, PSS seemed to reflect the degree of myocardial necrosis within the region of interest. (N.K.)

  14. Patterns of left ventricular remodeling among patients with essential and secondary hypertension.

    Science.gov (United States)

    Radulescu, Dan; Stoicescu, Laurentiu; Buzdugan, Elena; Donca, Valer

    2013-12-01

    High blood pressure causes left ventricular hypertrophy, which is a negative prognostic factor among hypertensive patients. To assess left ventricular geometric remodeling patterns in patients with essential hypertension or with hypertension secondary to parenchymal renal disease. We analyzed data from echocardiograms performed in 250 patients with essential hypertension (150 females) and 100 patients with secondary hypertension (60 females). The interventricular septum and the left ventricular posterior wall thickness were measured in the parasternal long-axis. Left ventricular mass was calculated using the Devereaux formula. The most common remodeling type in females and males with essential hypertension were eccentric and concentric left ventricular hypertrophy (cLVH), respectively. Among patients with secondary arterial hypertension, cLVH was most commonly observed in both genders. The prevalence of left ventricular hypertrophy was higher among patients with secondary hypertension. The left ventricular mass index and the relative left ventricular wall thickness were higher in males and also in the secondary hypertension group. Age, blood pressure values and the duration of hypertension, influenced remodeling patterns. We documented a higher prevalence of LVH among patients with secondary hypertension. The type of ventricular remodeling depends on gender, age, type of hypertension, blood pressure values and the duration of hypertension.

  15. Impact of aortic prosthesis-patient mismatch on left ventricular mass regression.

    Science.gov (United States)

    Alassal, Mohamed A; Ibrahim, Bedir M; Elsadeck, Nabil

    2014-06-01

    Prostheses used for aortic valve replacement may be small in relation to body size, causing prosthesis-patient mismatch and delaying left ventricular mass regression. This study examined the effect of prosthesis-patient mismatch on regression of left ventricular mass after aortic valve replacement. We prospectively studied 96 patients undergoing aortic valve replacement between 2007 and 2012. Mean and peak gradients and indexed effective orifice area were measured by transthoracic echocardiography at 3 and 6 months postoperatively. Patient-prosthesis mismatch was defined as indexed effective orifice area ≤0.85 cm(2)·m(-2). Moderate prosthesis-patient mismatch was present in 25% of patients. There were no significant differences in demographic and operative data between patients with and without prosthesis-patient mismatch. Left ventricular dimensions, posterior wall thickness, transvalvular gradients, and left ventricular mass decreased significantly after aortic valve replacement in both groups. The interventricular septal diameter and left ventricular mass index regression, and left ventricular ejection fraction were better in patients without prosthesis-patient mismatch. There was a significant positive correlation between the postoperative indexed effective orifice area of each valve prosthesis and the rate of left ventricular mass regression. Prosthesis-patient mismatch leads to higher transprosthetic gradients and impaired left ventricular mass regression. A small-sized valve prosthesis does not necessarily result in prosthesis-patient mismatch, and may be perfectly adequate in patient with small body size. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  16. Left ventricular diastolic dysfunction in chronic renal failure patients on chronic hemodialysis in Dr. Cipto-Mangunkusumo Hospital : the association with left ventricular mass

    Directory of Open Access Journals (Sweden)

    Idrus Alwi

    2006-06-01

    Full Text Available Fourty three patients with chronic renal failure undergoing chronic hemodialysis in Division of Nephrology and Hypertension, Faculty of Medicine, University of Indonesia/Cipto-Mangunkusumo Hospital, Jakarta, since October 2003 until February 2004, were examined for echocardiography (2-D, M-mode, Doppler imaging.Diastolic dysfunction was found in 58.1 % of chronic renal failure patients on hemodialysis. There was no significant difference between left ventricular mass in the group with or without left ventricular diastolic dysfunction. (Med J Indones 2006; 15:105-8Keywords: Left ventricular mass, diastolic function, chronic renal failure, hemodyalisis

  17. Skin Sodium Concentration Correlates with Left Ventricular Hypertrophy in CKD.

    Science.gov (United States)

    Schneider, Markus P; Raff, Ulrike; Kopp, Christoph; Scheppach, Johannes B; Toncar, Sebastian; Wanner, Christoph; Schlieper, Georg; Saritas, Turgay; Floege, Jürgen; Schmid, Matthias; Birukov, Anna; Dahlmann, Anke; Linz, Peter; Janka, Rolf; Uder, Michael; Schmieder, Roland E; Titze, Jens M; Eckardt, Kai-Uwe

    2017-06-01

    The pathogenesis of left ventricular hypertrophy in patients with CKD is incompletely understood. Sodium intake, which is usually assessed by measuring urinary sodium excretion, has been inconsistently linked with left ventricular hypertrophy. However, tissues such as skin and muscle may store sodium. Using 23 sodium-magnetic resonance imaging, a technique recently developed for the assessment of tissue sodium content in humans, we determined skin sodium content at the level of the calf in 99 patients with mild to moderate CKD (42 women; median [range] age, 65 [23-78] years). We also assessed total body overhydration (bioimpedance spectroscopy), 24-hour BP, and left ventricular mass (cardiac magnetic resonance imaging). Skin sodium content, but not total body overhydration, correlated with systolic BP ( r =0.33, P =0.002). Moreover, skin sodium content correlated more strongly than total body overhydration did with left ventricular mass ( r =0.56, P skin sodium content is a strong explanatory variable for left ventricular mass, unaffected by BP and total body overhydration. In conclusion, we found skin sodium content to be closely linked to left ventricular mass in patients with CKD. Interventions that reduce skin sodium content might improve cardiovascular outcomes in these patients. Copyright © 2017 by the American Society of Nephrology.

  18. Cardiothoracic ratio may be misleading in the assessment of right- and left-ventricular size in patients with repaired tetralogy of Fallot

    International Nuclear Information System (INIS)

    Śpiewak, M.; Małek, Ł.A.; Biernacka, E.K.; Kowalski, M.; Michałowska, I.; Hoffman, P.; Miśko, J.; Demkow, M.; Rużyłło, W.; Marczak, M.

    2014-01-01

    Aim: To assess the relationship between cardiothoracic ratio (CTR) and ventricular and atrial volumes in patients with repaired tetralogy of Fallot (TOF). Materials and methods: Patients with repaired TOF undergoing cardiac magnetic resonance (CMR) and chest radiography within 1 day were included (n = 82; median age: 24.7 years, interquartile range: 21.5–35.9). The CTR was obtained from upright posteroanterior chest roentgenograms. Analyses of CMR images and radiographs were performed in a blinded fashion. Results: There were 35.1% (13/37) of patients with normal CTR (<0.5) who had severe right ventricular (RV) dilatation. There were six patients (13.3%, 6/45) with high CTR with both normal RV and left-ventricular (LV) volumes. CTR did not correlate with either RV or LV volumes but showed a weak correlation with right- and left-atrial volumes (r = 0.43, p = 0.0001; r = 0.27, p = 0.01, respectively). CTR ≥0.5 showed poor ability in the identification of severe RV dilatation (sensitivity: 61.8%, specificity: 50%). The combination of CTR and signs of RV enlargement on lateral radiographs did not improve the diagnostic accuracy of any of those parameters alone. Conclusion: CTR in patients with repaired TOF reflected atrial rather than ventricular dilatation. The use of CTR or lateral radiographs in patients with repaired TOF may lead to false conclusions concerning ventricular size. - Highlights: • Cardiothoracic ratio did not correlate with either right- or left-ventricular volumes. • Cardiothoracic ratio reflected atrial rather than ventricular dilatation. • Normal cardiothoracic ratio did not exclude severe right ventricular dilatation. • Neither RVEF nor LVEF showed correlation with cardiothoracic ratio

  19. Longitudinal strain predicts left ventricular mass regression after aortic valve replacement for severe aortic stenosis and preserved left ventricular function.

    Science.gov (United States)

    Gelsomino, Sandro; Lucà, Fabiana; Parise, Orlando; Lorusso, Roberto; Rao, Carmelo Massimiliano; Vizzardi, Enrico; Gensini, Gian Franco; Maessen, Jos G

    2013-11-01

    We explored the influence of global longitudinal strain (GLS) measured with two-dimensional speckle-tracking echocardiography on left ventricular mass regression (LVMR) in patients with pure aortic stenosis (AS) and normal left ventricular function undergoing aortic valve replacement (AVR). The study population included 83 patients with severe AS (aortic valve area regression (all P regression in patients with pure AS undergoing AVR. Our findings must be confirmed by further larger studies.

  20. Paradox image: a noninvasive index of regional left-ventricular dyskinesis

    International Nuclear Information System (INIS)

    Holman, B.L.; Wynne, J.; Idoine, J.; Zielonka, J.; Neill, J.

    1979-01-01

    The paradox image, a functional image of regional dyskinesis derived from the equilibrium (gated) radionuclide ventriculogram, was constructed by subtracting the background-corrected end-diastolic frame from the background-corrected end-systolic frame. In 11 patients showing dyskinesis by contrast ventriculography, the percentage of left-ventricular picture elements containing paradox ranged from 3.6 to 55.6% (21.44% +- 4.45 s.e.m.). In 11 patients with normokinesis and in eight patients with hypookinesis by contrast ventriculography, the left-ventricular picture elements demonstrating paradox were less than 1.1% in all cases. In nine patients with akinesis, the percentage of left-ventricular picture elements containing paradox was 2.05% +- 0.96 s.e.m. and was less than 2% in seven patients. There was also an excellent agreement between the location of dyskinesis on the paradox image and that by contrast ventriculography. The paradox image is a sensitive indicator of left-ventricular dyskinesis and should be useful in the evaluation of patients with suspected left-ventricular asynergy

  1. Validity of automated measurement of left ventricular ejection fraction and volume using the Philips EPIQ system.

    Science.gov (United States)

    Hovnanians, Ninel; Win, Theresa; Makkiya, Mohammed; Zheng, Qi; Taub, Cynthia

    2017-11-01

    To assess the efficiency and reproducibility of automated measurements of left ventricular (LV) volumes and LV ejection fraction (LVEF) in comparison to manually traced biplane Simpson's method. This is a single-center prospective study. Apical four- and two-chamber views were acquired in patients in sinus rhythm. Two operators independently measured LV volumes and LVEF using biplane Simpson's method. In addition, the image analysis software a2DQ on the Philips EPIQ system was applied to automatically assess the LV volumes and LVEF. Time spent on each analysis, using both methods, was documented. Concordance of echocardiographic measures was evaluated using intraclass correlation (ICC) and Bland-Altman analysis. Manual tracing and automated measurement of LV volumes and LVEF were performed in 184 patients with a mean age of 67.3 ± 17.3 years and BMI 28.0 ± 6.8 kg/m 2 . ICC and Bland-Altman analysis showed good agreements between manual and automated methods measuring LVEF, end-systolic, and end-diastolic volumes. The average analysis time was significantly less using the automated method than manual tracing (116 vs 217 seconds/patient, P Automated measurement using the novel image analysis software a2DQ on the Philips EPIQ system produced accurate, efficient, and reproducible assessment of LV volumes and LVEF compared with manual measurement. © 2017, Wiley Periodicals, Inc.

  2. Left ventricular dysfunction after closure of large patent ductus arteriosus.

    Science.gov (United States)

    Galal, M Omar; Amin, Mohamed; Hussein, Arif; Kouatli, Amjad; Al-Ata, Jameel; Jamjoom, Ahmed

    2005-03-01

    Changes in left ventricular dimensions and performance were studied in 43 patients after transcatheter occlusion or surgical ligation of patent ductus arteriosus. The patients were assigned to 2 groups based on their ductal diameter: >/= 3.1 mm to group A (n = 27) and ventricular end-diastolic diameter than group B, while all patients had normal shortening fraction and ejection fraction. Within 1 month after intervention, left ventricular end-diastolic diameter showed a trend towards regression while shortening fraction and ejection fraction decreased significantly in group A. There were no significant changes in these parameters in group B. Between 1 and 6 months after intervention, left ventricular performance improved in most of the group A patients who were followed up. We conclude that closure of large ductus arteriosus in children leads to significant immediate deterioration of left ventricular performance, which appears to recover within a few months. Echocardiographic study before hospital discharge is recommended in these patients. Serious deterioration of ventricular performance after closure may warrant the use of angiotensin converting enzyme inhibitors.

  3. Problems in clinical assessment of left ventricular peak filling rate with radionuclide ventriculography

    Energy Technology Data Exchange (ETDEWEB)

    Ishida, Yoshio; Kim, Bong-Ha; Tsuneoka, Yutaka

    1987-02-01

    With an increased clinical application of early peak diastolic filling rate (PFR) using radionuclide ventriculography, problems of its clinical significance have emerged. The study was designed to answer the following questions: 1) accuracy of PFR measurement, 2) normalization of PFR, and 3) whether PFR may reflect left ventricular relaxation rate (LVRR). In measuring PFR, an elevated framing rate was required, and the optimal rate was 20 msec/F. Second sound heart gating technique proved to be complementary to conventional ECG R wave gating technique in the evaluation of left ventricular diastolic volume curves and mean filling rate associated with changes in the range of R-R interval. PFR which was normalized with end-diastolic volume (EDV) did not necessarily reflect measured PFR because of individual differences of EDV. An experiment on the relationship of mitral valve pressure to blood flow in dogs revealed that PFR was influenced by not only LVRR but also left atrial pressure. These results may raise a question of the rationale for using the measurement of PFR, as well as its technical problems, in the objective evaluation of LVRR. (Namekawa, K.).

  4. Preliminary study of left ventricular cavity-to-myocardial count ratio. A new parameter for left ventricular function

    International Nuclear Information System (INIS)

    Zhou Ying; Qu Wanying; Zhu Ming; Gao Wenping; Zhao Hongshan

    1995-01-01

    A new simple quantitative parameter, left ventricular cavity-to-myocardial count ratio (C/M ratio) was suggested and compared with LVEF to assess its reliability and clinical value. Of 220 patients in the study, 102 had both exercise 99m Tc-MIBI myocardial SPECT imaging and resting radionuclide ventriculography, another 118 patients had both rest 99m Tc-MIBI myocardial SPECT imaging and rest radionuclide ventriculography, 740 MBq of 99m Tc-MIBI was injected intravenously. Both the exercise and rest C/M ratio were determined on short-axis tomograms and LVEF were calculated from radionuclide ventriculography. The correlation between LVEF and the C/M (exercise and rest) was analyzed. There was a positive linear correlation between LVEF measured by ventriculography and both C/M exercise ratio (r = 0.6964) and C/M rest ratio (r = 0.6995). The sensitivity of C/M exercise and rest ratio for detecting patients with left ventricular dysfunction is 71.9%, 68.6%; the specificity is 92.9%, 97.0%; the accuracy is 86.3%, 84.7% respectively. C/M ratio can accurately identify patients with CAD who have resting left ventricular dysfunction. It was highly reproducible, reliable and useful in clinical diagnosis

  5. Global left ventricular function in cardiac CT. Evaluation of an automated 3D region-growing segmentation algorithm

    International Nuclear Information System (INIS)

    Muehlenbruch, Georg; Das, Marco; Hohl, Christian; Wildberger, Joachim E.; Guenther, Rolf W.; Mahnken, Andreas H.; Rinck, Daniel; Flohr, Thomas G.; Koos, Ralf; Knackstedt, Christian

    2006-01-01

    The purpose was to evaluate a new semi-automated 3D region-growing segmentation algorithm for functional analysis of the left ventricle in multislice CT (MSCT) of the heart. Twenty patients underwent contrast-enhanced MSCT of the heart (collimation 16 x 0.75 mm; 120 kV; 550 mAseff). Multiphase image reconstructions with 1-mm axial slices and 8-mm short-axis slices were performed. Left ventricular volume measurements (end-diastolic volume, end-systolic volume, ejection fraction and stroke volume) from manually drawn endocardial contours in the short axis slices were compared to semi-automated region-growing segmentation of the left ventricle from the 1-mm axial slices. The post-processing-time for both methods was recorded. Applying the new region-growing algorithm in 13/20 patients (65%), proper segmentation of the left ventricle was feasible. In these patients, the signal-to-noise ratio was higher than in the remaining patients (3.2±1.0 vs. 2.6±0.6). Volume measurements of both segmentation algorithms showed an excellent correlation (all P≤0.0001); the limits of agreement for the ejection fraction were 2.3±8.3 ml. In the patients with proper segmentation the mean post-processing time using the region-growing algorithm was diminished by 44.2%. On the basis of a good contrast-enhanced data set, a left ventricular volume analysis using the new semi-automated region-growing segmentation algorithm is technically feasible, accurate and more time-effective. (orig.)

  6. Agreement of left ventricular ejection fraction and volumes between adenosine stress TL-201 gated SPECT and echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Pai, M. S. [College of Medicine, Univ. of Ewha, Seoul (Korea, Republic of); Moon, D. H.; Kim, H. M.; Yang, Y. J.; Kang, D. H. [Asan Medical Center, Seoul (Korea, Republic of)

    2003-07-01

    Electrocardiogram-gated TI-201 SPECT measurements of left ventricular ejection fraction (EF), end-diastolic volume (EDV), and end-systolic volume (ESV) have shown high correlation with conventional methods. However, how much these parameters measured by TI-201 gated SPECT differ from those by echocardiography has not been assessed. Adenosine stress (Ad-G) and redistribution TI-201 gated SPECT (Re-G) and resting echocardiography were conducted in 337 patients (184 male, 153 female). EDV, ESV and LVEF measured by QGS software were compared with the results by echocardiography. Patients with arrhythmia (atrial fibrillation or frequent premature contractions) or evidence of fixed or reversible perfusion defects on TI-201 SPECT were excluded. EF, EDV and ESV measured by Ad-G (63.3{+-}9.8,73.8{+-}30.2,29.1{+-}20.1) and Re-G (65.2{+-}11.6,69.1{+-}30.1,26.5{+-}20.3) correlated well with those by Echo (61.4{+-}7.9,78.3{+-}2.7, 30.7{+-} 17.5 ; r of Ad-G=0.547, 0.850, 0.827, p<0.001 ; r of Re-G=0.585, 0.838, 0.819, p<0.001). However the difference (mean, SD, SEE of Echo - gated SPECT) was statistically significant (EF: Ad-G=1.71, 8.92, 0.48, Re-G=3.59, 10.39, 0.56, p<0.001 ; EDV: Ad-G=4.75, 16.21, 0.88, Re-G=9.53, 16.77, 0.91, p<0.001 ; ESV: Ad-G=1.75, 11.35, 0.61, p<0.05, Re-G=4.29, 11.7, 0.63, p<0.001). Bland-Altman plots showed that the difference of EDV and ESV did not vary in any systematic way over the range of measurement, whereas the difference of EF increased with increasing average EF by Echo and gated-SPECT. The difference of EF, EDV, and ESV between Ad-G and Echo was significantly smaller than those between Re-G and Echo (p<0.001). Gated TI-201 SPECT underestimates EDV and ESV over a wide range of volume. As a result, EF by gated TI-201 SPECT is overestimated especially in patients with small LV volume. Ad-G is preferable to Re-G in assessing left ventricular ejection fraction and volume in place of Echo because of smaller bias.

  7. Right Ventricular Outflow Tract Tachycardia with Structural Abnormalities of the Right Ventricle and Left Ventricular Diverticulum

    Directory of Open Access Journals (Sweden)

    Bortolo Martini

    2015-01-01

    Full Text Available A 43-year-old woman presented to the emergency room with a sustained ventricular tachycardia (VT. ECG showed a QRS in left bundle branch block morphology with inferior axis. Echocardiography, ventricular angiography, and cardiac magnetic resonance imaging (CMRI revealed a normal right ventricle and a left ventricular diverticulum. Electrophysiology studies with epicardial voltage mapping identified a large fibrotic area in the inferolateral layer of the right ventricular wall and a small area of fibrotic tissue at the anterior right ventricular outflow tract. VT ablation was successfully performed with combined epicardial and endocardial approaches.

  8. Normal left ventricular emptying in coronary artery disease at rest: analysis by radiographic and equilibrium radionuclide ventriculography

    International Nuclear Information System (INIS)

    Denenberg, B.S.; Makler, P.T.; Bove, A.A.; Spann, J.F.

    1981-01-01

    The volume ejected early in systole has been proposed as an indicator of abnormal left ventricular function that is present at rest in patients with coronary artery disease with a normal ejection fraction and normal wall motion. The volume ejected in systole was examined by calculating the percent change in ventricular volume using both computer-assisted analysis of biplane radiographic ventriculograms at 60 frames/s and equilibrium gated radionuclide ventriculograms. Ventricular emptying was examined with radiographic ventriculography in 33 normal patients and 23 patients with coronary artery disease and normal ejection fraction. Eight normal subjects and six patients with coronary artery disease had both radiographic ventriculography and equilibrium gated radionuclide ventriculography. In all patients, there was excellent correlation between the radiographic and radionuclide ventricular emptying curves (r . 0.971). There were no difference in the ventricular emptying curves of normal subjects and patients with coronary artery disease whether volumes were measured by radiographic or equilibrium gated radionuclide ventriculography. It is concluded that the resting ventricular emptying curves are identical in normal subjects and patients with coronary artery disease who have a normal ejection fraction and normal wall motion

  9. Multi-slice CT (MSCT) in cardiac function imaging: threshold-value-supported 3D volume reconstructions to determine the left ventricular ejection fraction in comparison to MRI

    International Nuclear Information System (INIS)

    Ehrhard, K.; Oberholzer, K.; Gast, K.; Mildenberger, P.; Kreitner, K.F.; Thelen, M.

    2002-01-01

    Purpose: To assess MSCT of the heart to determining left ventricular ejection fraction (EF) based on threshold-value-supported 3D volume reconstructions compared to MRI. Methods: Cardiac MSCT was performed in 7 patients. Images were reconstructed during end-systolic and end-diastolic phases of the cardiac cycle and transformed to 3D volumes to determine end-systolic (ESV) and end-diastolic volume (EDV) by using different lower threshold values: besides fixed lower threshold values, identical for each image sequence, individual lower threshold values dependent on contrast enhancement of the left ventricle were applied. The latter represent the mean value calculated by combining the average CT-density of the myocardium and the contrast-enhanced blood in the left ventricle. The EF derived from ESV and EDV. Results: The best correlation with MR imaging was obtained for ESV and EDV by using the individual lower threshold values for the respective sequence. The correlation coefficient for ESV was 0.95 and for EDV it was 0.93. On average, the ESV was overestimated by 3.72 ml, while the ESD was underestimated by 2.85 ml. The respective standard deviation for the ESV was 14,87 ml, for the EDV it was 26.83 ml. On average, the EF was underestimated by 3.57% with a standard deviation of 9.43% and a correlation coefficient of 0.83 in comparison to MRI. Conclusion: The threshold-value-supported 3D volume reconstruction of the left ventricle represents a good method to determine the left ventricular function parameters. Due to the differences in the contrast enhancement, the use of an individual lower threshold value for every image sequence is of particular importance. (orig.) [de

  10. Left atrial systolic force in hypertensive patients with left ventricular hypertrophy: the LIFE study

    DEFF Research Database (Denmark)

    Chinali, M.; Simone, G. de; Wachtell, K.

    2008-01-01

    In hypertensive patients without prevalent cardiovascular disease, enhanced left atrial systolic force is associated with left ventricular hypertrophy and increased preload. It also predicts cardiovascular events in a population with high prevalence of obesity. Relations between left atrial...... systolic force and left ventricular geometry and function have not been investigated in high-risk hypertrophic hypertensive patients. Participants in the Losartan Intervention For Endpoint reduction in hypertension echocardiography substudy without prevalent cardiovascular disease or atrial fibrillation (n...... = 567) underwent standard Doppler echocardiography. Left atrial systolic force was obtained from the mitral orifice area and Doppler mitral peak A velocity. Patients were divided into groups with normal or increased left atrial systolic force (>14.33 kdyn). Left atrial systolic force was high in 297...

  11. Association between left ventricular global longitudinal strain and natriuretic peptides in outpatients with chronic systolic heart failure

    DEFF Research Database (Denmark)

    Gaborit, F; Bosselmann, H; Tønder, N

    2015-01-01

    BACKGROUND: Both impaired left ventricular (LV) global longitudinal strain (GLS) and increased plasma concentrations of natriuretic peptides(NP) are associated with a poor outcome in heart failure (HF). Increased levels of NP reflect increased wall stress of the LV. However, little is known about.......28-8.30, P = 0.013) and linear regression (NT-proBNP: βGLS: 1.19, 95 %-CI: 0.62-1.76, P renal function) and left atrial volume index....... CONCLUSION: Impaired LV GLS is associated with increased plasma concentrations of NP and our data suggest that left ventricular myocardial mechanics estimated by LV GLS reflects myocardial wall stress in chronic systolic HF....

  12. Relation of N-Terminal Pro-B-Type Natriuretic Peptide and Left Ventricular Diastolic Function to Exercise Tolerance in Patients With Significant Valvular Heart Disease and Normal Left Ventricular Systolic Function.

    Science.gov (United States)

    Hwang, Ji-Won; Park, Sung-Ji; Cho, Eun Jeong; Kim, Eun Kyoung; Lee, Ga Yeon; Chang, Sung-A; Choi, Jin-Oh; Lee, Sang-Chol; Park, Seung Woo

    2017-06-01

    An association between N-terminal prohormone brain natriuretic peptide (NT-proBNP) and exercise tolerance in patients with valvular heart disease (VHD) has been suggested; however, there are few data available regarding this relation. The aim of this study is to evaluate the correlation between exercise tolerance and NT-proBNP in patients with asymptomatic or mildly symptomatic significant VHD and normal left ventricular ejection fraction (LV EF). A total of 96 patients with asymptomatic or mildly symptomatic VHD and normal LV EF (≥50%) underwent cardiopulmonary exercise echocardiography. NT-proBNP levels were determined at baseline and after exercise in 3 hours. Patients were divided in 2 groups based on lower (left atrial volume index before exercise, right ventricular systolic pressure before exercise, E velocity after exercise, and E/e' ratio after exercise varied significantly. In addition, peak VO 2 was inversely related to NT-proBNP before (r = -0.352, p left atrial volume index, E/e' ratio, and right ventricular systolic pressure before and after exercise. NT-proBNP after exercise was also directly related to the same parameters. NT-proBNP levels both before and after exercise were higher in the group with lower exercise tolerance. In conclusion, through the correlation among exercise tolerance, NT-proBNP, and parameters of diastolic dysfunction, we demonstrated that diastolic dysfunction and NT-proBNP could predict exercise tolerance in patients with significant VHD and normal LV EF. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Benefits of lifelong exercise training on left ventricular function after myocardial infarction.

    Science.gov (United States)

    Maessen, Martijn Fh; Eijsvogels, Thijs Mh; Stevens, Guus; van Dijk, Arie Pj; Hopman, Maria Te

    2017-11-01

    Background Endurance exercise training induces cardio-protective effects, but athletes are not exempted from a myocardial infarction. Evidence from animal studies suggests that exercise training attenuates pathological left ventricular remodelling following myocardial infarction. We tested the hypothesis that lifelong exercise training is related to attenuated pathological left ventricular remodelling after myocardial infarction as evidenced by better left ventricular systolic function in veteran athletes compared to sedentary peers. Design This was a cross-sectional study. Methods Sixty-five males (60 ± 6 years) were included and allocated to four groups based on lifelong exercise training volumes: (a) athletes ( n = 18), (b) post-myocardial infarction athletes (athletes + myocardial infarction, n = 20), (c) sedentary controls ( n = 13), and (d) post-myocardial infarction controls (sedentary controls + myocardial infarction, n = 14). Athletes were lifelong (≥20 years) highly physically active (≥30 metabolic equivalent of task (MET)-h/week), whereas sedentary controls did not meet the exercise guidelines (creatine-kinase, creatinine, aspartate transaminase and lactate dehydrogenase) following myocardial infarction and infarct location did not differ between athletes + myocardial infarction and sedentary controls + myocardial infarction. Left ventricular ejection fraction was significantly higher in athletes (61% ± 4), athletes + myocardial infarction (58% ± 4) and sedentary controls (57% ± 6) compared to sedentary controls + myocardial infarction (51% ± 7; p athletes (-19% (-21% to -17%), athletes + myocardial infarction (-16% (-20% to -12%)), and sedentary controls (-15% (-18% to -14%) compared to sedentary controls + myocardial infarction (-13% (-15% to -8%), p athletes.

  14. Improved accuracy in estimation of left ventricular function parameters from QGS software with Tc-99m tetrofosmin gated-SPECT. A multivariate analysis

    International Nuclear Information System (INIS)

    Okizaki, Atsutaka; Shuke, Noriyuki; Sato, Junichi; Ishikawa, Yukio; Yamamoto, Wakako; Kikuchi, Kenjiro; Aburano, Tamio

    2003-01-01

    The purpose of this study was to verify whether the accuracy of left ventricular parameters related to left ventricular function from gated-SPECT improved or not, using multivariate analysis. Ninety-six patients with cardiovascular diseases were studied. Gated-SPECT with the quantitative gated SPECT (QGS) software and left ventriculography (LVG) were performed to obtain left ventricular ejection fraction (LVEF), end-diastolic volume (EDV) and end-systolic volume (ESV). Then, multivariate analyses were performed to determine empirical formulas for predicting these parameters. The calculated values of left ventricular parameters were compared with those obtained directly from the QGS software and LVG. Multivariate analyses were able to improve accuracy in estimation of LVEF, EDV and ESV. Statistically significant improvement was seen in LVEF (from r=0.6965 to r=0.8093, p<0.05). Although not statistically significant, improvements in correlation coefficients were seen in EDV (from r=0.7199 to r=0.7595, p=0.2750) and ESV (from r=0.5694 to r=0.5871, p=0.4281). The empirical equations with multivariate analysis improved the accuracy in estimating LVEF from gated-SPECT with the QGS software. (author)

  15. The ratio of right ventricular volume to left ventricular volume reflects the impact of pulmonary regurgitation independently of the method of pulmonary regurgitation quantification

    Energy Technology Data Exchange (ETDEWEB)

    Śpiewak, Mateusz, E-mail: mspiewak@ikard.pl [Department of Coronary Artery Disease and Structural Heart Diseases, Institute of Cardiology, Warsaw (Poland); Cardiac Magnetic Resonance Unit, Institute of Cardiology, Warsaw (Poland); Małek, Łukasz A., E-mail: lmalek@ikard.pl [Cardiac Magnetic Resonance Unit, Institute of Cardiology, Warsaw (Poland); Department of Interventional Cardiology and Angiology, Institute of Cardiology, Warsaw (Poland); Petryka, Joanna, E-mail: joannapetryka@hotmail.com [Department of Coronary Artery Disease and Structural Heart Diseases, Institute of Cardiology, Warsaw (Poland); Cardiac Magnetic Resonance Unit, Institute of Cardiology, Warsaw (Poland); Mazurkiewicz, Łukasz, E-mail: lmazurkiewicz@ikard.pl [Cardiac Magnetic Resonance Unit, Institute of Cardiology, Warsaw (Poland); Department of Cardiomyopathy, Institute of Cardiology, Warsaw (Poland); Miłosz, Barbara, E-mail: barbara-milosz@o2.pl [Cardiac Magnetic Resonance Unit, Institute of Cardiology, Warsaw (Poland); Department of Radiology, Institute of Cardiology, Warsaw (Poland); Biernacka, Elżbieta K., E-mail: kbiernacka@ikard.pl [Department of Congenital Heart Diseases, Institute of Cardiology, Warsaw (Poland); Kowalski, Mirosław, E-mail: mkowalski@ikard.pl [Department of Congenital Heart Diseases, Institute of Cardiology, Warsaw (Poland); Hoffman, Piotr, E-mail: phoffman@ikard.pl [Department of Congenital Heart Diseases, Institute of Cardiology, Warsaw (Poland); Demkow, Marcin, E-mail: mdemkow@ikard.pl [Department of Coronary Artery Disease and Structural Heart Diseases, Institute of Cardiology, Warsaw (Poland); Miśko, Jolanta, E-mail: jmisko@wp.pl [Cardiac Magnetic Resonance Unit, Institute of Cardiology, Warsaw (Poland); Department of Radiology, Institute of Cardiology, Warsaw (Poland); Rużyłło, Witold, E-mail: wruzyllo@ikard.pl [Institute of Cardiology, Warsaw (Poland)

    2012-10-15

    Background: Previous studies have advocated quantifying pulmonary regurgitation (PR) by using PR volume (PRV) instead of commonly used PR fraction (PRF). However, physicians are not familiar with the use of PRV in clinical practice. The ratio of right ventricle (RV) volume to left ventricle volume (RV/LV) may better reflect the impact of PR on the heart than RV end-diastolic volume (RVEDV) alone. We aimed to compare the impact of PRV and PRF on RV size expressed as either the RV/LV ratio or RVEDV (mL/m{sup 2}). Methods: Consecutive patients with repaired tetralogy of Fallot were included (n = 53). PRV, PRF and ventricular volumes were measured with the use of cardiac magnetic resonance. Results: RVEDV was more closely correlated with PRV when compared with PRF (r = 0.686, p < 0.0001, and r = 0.430, p = 0.0014, respectively). On the other hand, both PRV and PRF showed a good correlation with the RV/LV ratio (r = 0.691, p < 0.0001, and r = 0.685, p < 0.0001, respectively). Receiver operating characteristic analysis showed that both measures of PR had similar ability to predict severe RV dilatation when the RV/LV ratio-based criterion was used, namely the RV/LV ratio > 2.0 [area under the curve (AUC){sub PRV} = 0.770 vs AUC{sub PRF} = 0.777, p = 0.86]. Conversely, with the use of the RVEDV-based criterion (>170 mL/m{sup 2}), PRV proved to be superior over PRF (AUC{sub PRV} = 0.770 vs AUC{sub PRF} = 0.656, p = 0.0028]. Conclusions: PRV and PRF have similar significance as measures of PR when the RV/LV ratio is used instead of RVEDV. The RV/LV ratio is a universal marker of RV dilatation independent of the method of PR quantification applied (PRF vs PRV)

  16. Beat-to-beat assessment of left ventricular ejection in atrial fibrillation

    International Nuclear Information System (INIS)

    Benjelloun, H.; Brochier, M.; Itti, R.; Philippe, L.; Lorgeron, J.M.

    1983-01-01

    Beat-to-beat left ventricular ejection was evaluated in a group of 20 patients with chronic atrial fibrillation using a computerized single probe detector. The reference group consisted of 10 patients with sinus rhythm. For each patient 30 successive cardiac cycles were analyzed and the relative variations of four parameters were assessed: R-R interval, diastolic and systolic time intervals, and ejection amplitude, corresponding to the left ventricular stroke volume. The mean variations were respectively 3.4%, 10.4%, 8.4%, and 11.8% in patients with sinus rhythm, and 21.9%, 37.9%, 10.6% and 30.5% in patients with artrial fibrillation. This demonstrates that changes in ejection are mainly related to the duration of the filling phase, with nearly constant systolic times. Correlations between R-R intervals and systolic ejection amplitudes were highly significant (P<0.001) in patients with atrial fibrillation in 85% of cases. This information complements the average ejection fraction obtained from multiple cycle superimposition. (orig.)

  17. Beat-to-beat assessment of left ventricular ejection in atrial fibrillation

    Energy Technology Data Exchange (ETDEWEB)

    Benjelloun, H; Brochier, M; Itti, R; Philippe, L; Lorgeron, J M

    1983-05-01

    Beat-to-beat left ventricular ejection was evaluated in a group of 20 patients with chronic atrial fibrillation using a computerized single probe detector. The reference group consisted of 10 patients with sinus rhythm. For each patient 30 successive cardiac cycles were analyzed and the relative variations of four parameters were assessed: R-R interval, diastolic and systolic time intervals, and ejection amplitude, corresponding to the left ventricular stroke volume. The mean variations were respectively 3.4%, 10.4%, 8.4%, and 11.8% in patients with sinus rhythm, and 21.9%, 37.9%, 10.6% and 30.5% in patients with artrial fibrillation. This demonstrates that changes in ejection are mainly related to the duration of the filling phase, with nearly constant systolic times. Correlations between R-R intervals and systolic ejection amplitudes were highly significant (P<0.001) in patients with atrial fibrillation in 85% of cases. This information complements the average ejection fraction obtained from multiple cycle superimposition.

  18. The impact of preload reduction with head-up tilt testing on longitudinal and transverse left ventricular mechanics: a study utilizing deformation volume analysis.

    Science.gov (United States)

    Schneider, Caroline; Forsythe, Lynsey; Somauroo, John; George, Keith; Oxborough, David

    2018-03-01

    Left ventricular (LV) function is dependent on load, intrinsic contractility and relaxation with a variable impact on specific mechanics. Strain (ε) imaging allows the assessment of cardiac function; however, the direct relationship between volume and strain is currently unknown. The aim of this study was to establish the impact of preload reduction through head-up tilt (HUT) testing on simultaneous left ventricular (LV) longitudinal and transverse function and their respective contribution to volume change. A focused transthoracic echocardiogram was performed on 10 healthy male participants (23 ± 3 years) in the supine position and following 1 min and 5 min of HUT testing. Raw temporal longitudinal ε (Ls) and transverse ε (Ts) values were exported and divided into 5% increments across the cardiac cycle and corresponding LV volumes were traced at each 5% increment. This provided simultaneous LV longitudinal and transverse ε and volume loops (deformation volume analysis - DVA). There was a leftward shift of the ε-volume loop from supine to 1 min and 5 min of HUT ( P  transverse thickening from supine to 1 min, which was further augmented at 5 min ( P  = 0.018). Preload reduction occurs within 1 min of HUT but does not further reduce at 5 min. This decline is associated with a decrease in longitudinal ε and concomitant increase in transverse ε. Consequently, augmented transverse relaxation appears to be an important factor in the maintenance of LV filling in the setting of reduced preload. DVA provides information on the relative contribution of mechanics to a change in LV volume and may have a role in the assessment of clinical populations. © 2018 The authors.

  19. Does left ventricular function improve with L-carnitine after acute myocardial infarction?

    Directory of Open Access Journals (Sweden)

    Iyer R

    1999-04-01

    Full Text Available A double blind randomized placebo controlled clinical trial was carried out to assess the efficacy and safety of L-carnitine in patients suffering from acute anterior wall myocardial infarction with respect to left ventricular function. Sixty patients (34 men, 26 women, mean age 56+11 yr. with acute anterior wall myocardial infarction were randomized to placebo and L-carnitine. All the patients were given intravenous L-carnitine / placebo in the dose of 6gm/day for the first seven days followed by oral L-carnitine / placebo 3 gm/day in three divided doses for a period of three months. Echocardiography was performed for regional wall motion abnormality, left ventricular end systolic volume (ESV, end diastolic volume (EDV and ejection fraction (EF on admission, after seven days and after three months of the infarction. Forty-four patients completed the study. There were three deaths, two in the placebo and one in the L-carnitine group (p>0.05. Thirteen patients were lost to follow up. Echo parameters in both groups were comparable (p>0.05. The duration of chest pain prior to initiation of the I.V. L-carnitine was 7.5 + 5.2 hrs in the L-carnitine group and 7 + 4 hrs in the placebo group (p>0.05. There was no statistical difference in the EF, ESV and EDV on admission, at discharge and after three months in the L-carnitine and the placebo groups (p>0.05. No significant adverse effects were noted. L-carnitine, though a safe drug, does not affect the left ventricular function in patients with myocardial infarction.

  20. Left ventricular filling under elevated left atrial pressure

    Science.gov (United States)

    Gaddam, Manikantam; Samaee, Milad; Santhanakrishnan, Arvind

    2017-11-01

    Left atrial pressure (LAP) is elevated in diastolic dysfunction, where left ventricular (LV) filling is impaired due to increase in ventricular stiffness. The impact of increasing LAP and LV stiffness on intraventricular filling hemodynamics remains unclear. We conducted particle image velocimetry and hemodynamics measurements in a left heart simulator (LHS) under increasing LAP and LV stiffness at a heart rate of 70 bpm. The LHS consisted of a flexible-walled LV physical model fitted within a fluid-filled chamber. LV wall motion was generated by a piston pump that imparted pressure fluctuations in the chamber. Resistance and compliance elements in the flow loop were adjusted to obtain bulk physiological hemodynamics in the least stiff LV model. Two LV models of increasing stiffness were subsequently tested under unchanged loop settings. LAP was varied between 5-20 mm Hg for each LV model, by adjusting fluid level in a reservoir upstream of the LV. For constant LV stiffness, increasing LAP lowered cardiac output (CO), while ejection fraction (EF) and E/A ratio were increased. For constant LAP, increasing LV stiffness lowered CO and EF, and increased E/A ratio. The implications of these altered hemodynamics on intraventricular filling vortex characteristics will be presented.

  1. Right heart ejection fraction, ventricular volumes, and left to right cardiac shunt measurements with a conventional Anger camera in congenital heart disease

    International Nuclear Information System (INIS)

    Cook, S.A.; Go, R.T.; MacIntyre, W.J.; Moodie, D.S.; Houser, T.S.; Ceimo, J.; Underwood, D.; Yiannikas, J.

    1982-01-01

    The object of this investigation was to demonstrate that a conventional Anger camera can be used for measurement of right heart ejection fraction, ventricular volumes and left to right shunts in routine clinical determinations. The automatic selection of chamber and lung regions, the recirculation subtraction of recirculation, and the filtering of the right heart ejection fraction dilution curves are all done entirely without operator intervention. Thus, this entire evaluation has been incorporated into the routine procedures of patient care

  2. Effect of left ventricular diastolic dysfunction on left atrial appendage function and thrombotic potential in nonvalvular atrial fibrillation.

    Science.gov (United States)

    Demirçelik, Muhammed Bora; Çetin, Mustafa; Çiçekcioğlu, Hülya; Uçar, Özgül; Duran, Mustafa

    2014-05-01

    We aimed to investigate effects of left ventricular diastolic dysfunction on left atrial appendage functions, spontaneous echo contrast and thrombus formation in patients with nonvalvular atrial fibrillation. In 58 patients with chronic nonvalvular atrial fibrilation and preserved left ventricular systolic function, left atrial appendage functions, left atrial spontaneous echo contrast grading and left ventricular diastolic functions were evaluated using transthoracic and transoesophageal echocardiogram. Patients divided in two groups: Group D (n=30): Patients with diastolic dysfunction, Group N (n=28): Patients without diastolic dysfunction. Categorical variables in two groups were evaluated with Pearson's chi-square or Fisher's exact test. The significance of the lineer correlation between the degree of spontaneous echo contrast (SEC) and clinical measurements was evaluated with Spearman's correlation analysis. Peak pulmonary vein D velocity of the Group D was significantly higher than the Group N (p=0.006). However, left atrial appendage emptying velocity, left atrial appendage lateral wall velocity, peak pulmonary vein S, pulmonary vein S/D ratio were found to be significantly lower in Group D (p=0.028, patrial appendage emptying, filling, pulmonary vein S/D levels and lateral wall velocities respectively (r=-0.438, r=-0.328, r=-0.233, r=-0.447). Left atrial appendage emptying, filling, pulmonary vein S/D levels and lateral wall velocities were significantly lower in SEC 2-3-4 than SEC 1 (p=0.003, p=0.029, patrial fibrillation and preserved left ventricular ejection fraction, left atrial appendage functions are decreased in patients with left ventricular diastolic dysfunction. Left ventricular diastolic dysfunction may constitute a potential risk for formation of thrombus and stroke.

  3. Association between circulating fibroblast growth factor 23, α-Klotho, and the left ventricular ejection fraction and left ventricular mass in cardiology inpatients.

    Directory of Open Access Journals (Sweden)

    Kensaku Shibata

    Full Text Available BACKGROUND: Fibroblast growth factor 23 (FGF23, with its co-receptor Klotho, plays a crucial role in phosphate metabolism. Several recent studies suggested that circulating FGF23 and α-Klotho concentrations might be related to cardiovascular abnormalities in patients with advanced renal failure. PURPOSE: Using data from 100 cardiology inpatients who were not undergoing chronic hemodialysis, the association of circulating levels of FGF23, α-Klotho, and other calcium-phosphate metabolism-related parameters with the left ventricular ejection fraction (LVEF and left ventricular mass (LVM was analyzed. METHODS AND RESULTS: LVEF was measured using the modified Simpson method for apical 4-chamber LV images and the LVM index (LVMI was calculated by dividing the LVM by body surface area. Univariate analysis showed that log transformed FGF23, but not that of α-Klotho, was significantly associated with LVEF and LVMI with a standardized beta of -0.35 (P<0.001 and 0.26 (P<0.05, respectively. After adjusting for age, sex, estimated glomerular filtration rate, and serum concentrations of intact parathyroid hormone, and 25-hydroxyvitamin D as covariates into the statistical model, log-transformed FGF23 was found to be a statistically positive predictor for decreased left ventricular function and left ventricular hypertrophy. CONCLUSIONS: In cardiology department inpatients, circulating FGF23 concentrations were found to be associated with the left ventricular mass and LVEF independent of renal function and other calcium-phosphate metabolism-related parameters. Whether modulation of circulating FGF23 levels would improve cardiac outcome in such a high risk population awaits further investigation.

  4. Right ventricular failure after implantation of a continuous-flow left ventricular assist device

    DEFF Research Database (Denmark)

    Cordtz, Johan Joakim; Nilsson, Jens C; Hansen, Peter B

    2014-01-01

    Right ventricular failure (RVF) is a significant complication after implantation of a left ventricular assist device. We aimed to identify haemodynamic changes in the early postoperative phase that predicted subsequent development of RVF in a cohort of HeartMate II (HMII) implanted patients....

  5. Effect of sex on wasted left ventricular effort following maximal exercise.

    Science.gov (United States)

    Lane, A D; Ranadive, S M; Yan, H; Kappus, R M; Cook, M D; Sun, P; Woods, J A; Wilund, K; Fernhall, B

    2013-09-01

    Wasted left ventricular effort (∆Ew) refers to work required of the left ventricle to eject blood that does not result in increased stroke volume and is related to left ventricular hypertrophy. Literature shows that men and women have differing ventricular and vascular responses to and following exercise. Our purpose was to determine how ∆Ew changes post-exercise in men and women and examine potential mechanisms. We hypothesized a reduction in ∆Ew that would be greater in men and that central pulse wave velocity and wave intensity (WIA) would be related to ∆Ew. Blood pressures, central pulse wave velocity (cPWV), and WIA were obtained at rest, 15 and 30 min after maximal exercise. Both sexes reduced ∆Ew post-maximal exercise (p>0.05 for interaction), but women had higher ∆Ew at each time point (p<0.05). The first peak of WIA increased 15 min post-exercise only in women (p<0.05). cPWV was attenuated (p<0.05) in women at 15 min and men at 30 min (p<0.05) post-exercise with a significant time by sex interaction (p<0.05). WIA (1st peak) was correlated (p<0.05) to ∆Ew in both sexes before and 15 min post-exercise, but cPWV was only associated with ∆Ew in men at 30 min post-exercise. We conclude that both sexes decrease ∆Ew after maximal exercise, but vascular and ventricular changes associated with the attenuation of ∆Ew are not uniform between sexes. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Gender differences in left ventricular function in patients with isolated aortic stenosis.

    Science.gov (United States)

    Favero, Luca; Giordan, Massimo; Tarantini, Giuseppe; Ramondo, Angelo Bruno; Cardaioli, Paolo; Isabella, Giambattista; Chioin, Raffaello; Lupia, Mario; Razzolini, Renato

    2003-05-01

    Hypertrophic response of the left ventricle to systolic overload in aortic stenosis appears to be gender-dependent. To examine gender-related differences in left ventricular (LV) function in patients with isolated severe aortic stenosis, 145 patients (65 women, 80 men; mean age 66 +/- 8 years; range: 50 to 89 years) with aortic valve area 199 mmHg, the mass:volume ratio was increased in men compared with women; of note, the mass:volume ratio in women was not increased in this subgroup compared with the general population. LV pump function in this subgroup was normal and did not differ between men and women. Although no clear-cut difference in hemodynamic parameters was seen, there was a trend towards a less compensatory increase in LV mass in females.

  7. Isolated left ventricular non-compaction cardiomyopathy associated with polymorphous ventricular tachycardia mimicking torsades de pointes

    Directory of Open Access Journals (Sweden)

    Oana Dickinson

    2013-02-01

    Full Text Available Left ventricular non-compaction (LVNC cardiomyopathy is a rare congenital disorder, classified by the American Heart Association as a primary genetic cardiomyopathy and characterized by multiple trabeculations within the left ventricle. LVNC cardiomyopathy has been associated with 3 major clinical manifestations: heart failure, atrial and ventricular arrhythmias and thromboembolic events, including stroke. In this case report, we describe a female patient with apparently isolated LVNC in whom pause-dependent polymorphic ventricular tachycardia suggesting torsades de pointes occurred in the presence of a normal QT interval.

  8. Regional ejection fraction: a quantitative radionuclide index of regional left ventricular performance

    International Nuclear Information System (INIS)

    Maddox, D.E.; Wynne, J.; Uren, R.; Parker, J.A.; Idoine, J.; Siegel, L.C.; Neill, J.M.; Cohn, P.F.; Holman, B.L.

    1979-01-01

    Left ventricular regional ejection fractions were derived from background-corrected, time-activity curves in 43 patients assessed by both gated equilibrium radionuclide angiocardiography and left ventricular contrast angiography. From a single, modified left anterior oblique projection, the regional change in background corrected counts was determined in each of three anatomic regions. The normal range for regional radionuclide ejection fraction was determined in 10 patients with normal contrast ventriculograms and without obstructive coronary artery disease at coronary arteriography. Regional ejection fraction was compared with percent segmental axis shortening and extent of akinetic segments in corresponding regions of the contrast ventriculogram. Radionuclide and roentgenographic methods were in agreement as to the presence or absence of abnormal wall motion in 83 of 99 left ventricular regions (84%) in 33 patients evaluated prospectively. Comparison of regional ejection fraction demonstrated significant differences between regions with roentgenographically determined normokinesis hypokinesis, and akinesis. We conclude that the left ventricular regional ejection fraction provides a reliable quantitative assessment of regional left ventricular performance

  9. Surgical myocardial revascularization in patients with reduced systolic left ventricular function.

    Science.gov (United States)

    Bruno, Piergiorgio; Iafrancesco, Mauro; Massetti, Massimo

    2018-04-20

    Surgical myocardial revascularization in patients with reduced left ventricular function has been a matter of debate for decades. Recently published 10-years extension follow-up of the STICH trial have conclusively demonstrated benefit of surgical myocardial revascularization in patients with significant coronary artery disease and low left ventricular ejection fraction. However, selection of patients for surgery remains challenging as well as decision to perform percutaneous rather than surgical revascularization in this class of patients. New evidence helped to clarify the role of preoperative patients' characteristics as risk factors for surgery and to identify those patients who may benefit the most from surgery. Focus of this review is to review epidemiology, aetiology and pathophysiology of coronary artery disease in patients with reduced left ventricular function, role of viability and results of observational and investigational studies on revascularization in patients with reduced left ventricular function with a particular emphasis on relative indication of coronary artery bypass grafting and percutaneous coronary intervention and the surgical implications of development of ischemic mitral regurgitation or ischemic left ventricular aneurysm.

  10. Phase image characterization of ventricular contraction in left anterior hemiblock

    International Nuclear Information System (INIS)

    Ono, Akifumi; Mizuno, Haruyoshi; Tahara, Yorio; Ishikawa, Kyozo

    1991-01-01

    We investigated whether or not left anterior hemiblock is present in patients with left axis deviation using first-harmonic Fourier analysis of gated blood-pool images. Gated blood-pool images were taken in 50 patients without contraction abnormality. They included 14 normal subjects, 8 patients with right bundle branch block (RBBB), 20 with left axis deviation (LAD) and 8 with both RBBB and LAD (RBBB+LAD). ECG gated blood-pool scans were acquired in the anterior and 'best septal' left anterior oblique projections. First, the phase images were displayed cinematically as a continuous-loop movie. Next, for quantitative analysis of the phase image, the whole left ventricular and left ventricular high lateral regions of interest were drawn. The 'regional phase shift' (RPS) was then defined as {RPS=A-a} where 'A' is the mean value of the whole left ventricular phase angles and 'a' is that of phase angles in the high lateral region. The left ventricular phase changes and the RPSs in the RBBB and LAD groups were similar to those in the normal group. In the RBBB+LAD group, the latest phase changes occurred in the high anterolateral region. The RPSs of this group were significantly lower than those in the other 3 groups (p<0.01). These data suggest that left anterior hemiblock might coexist with RBBB in patients with RBBB+LAD, whereas left anterior hemiblock might not exist in the majority of patients with LAD alone. (author)

  11. Increased left ventricular myocardial extracellular volume is associated with longer cardiopulmonary bypass times, biventricular enlargement and reduced exercise tolerance in children after repair of Tetralogy of Fallot.

    Science.gov (United States)

    Riesenkampff, Eugénie; Luining, Wietske; Seed, Mike; Chungsomprasong, Paweena; Manlhiot, Cedric; Elders, Bernadette; McCrindle, Brian W; Yoo, Shi-Joon; Grosse-Wortmann, Lars

    2016-10-26

    Unfavorable left ventricular (LV) remodelling may be associated with adverse outcomes after Tetralogy of Fallot (TOF) repair. We sought to assess T1 cardiovascular magnetic resonance (CMR) markers of diffuse LV myocardial fibrosis in children after TOF repair, and associated factors. In this prospective, cross-sectional study, native (=non-contrast) T1 times and extracellular volume fraction (ECV) were quantified in the LV myocardium using CMR. Results were related to ventricular volumes and function, degree of pulmonary regurgitation, as well as surgical characteristics, and exercise capacity. There was no difference in native T1 times or ECV between 31 TOF patients (age at CMR 13.9 ± 2.4 years, 19 male) and 15 controls (age at CMR 13.4 ± 2.6 years, 7 male). Female TOF patients had higher ECVs than males (25.2 ± 2.9 % versus 22.7 ± 3.3 %, p < 0.05). In the patient group, higher native T1 and ECV correlated with higher Z-Scores of right and left ventricular end-diastolic volumes, but not with reduced left and right ventricular ejection fraction or higher pulmonary regurgitation fraction. Longer cardiopulmonary bypass and aortic cross clamp times at surgery correlated with increased native T1 times and ECVs (r = 0.48, p < 0.05 and r = 0.65, p < 0.01, respectively). Maximum workload (percent of predicted for normal) correlated inversely with ECV (r = -0.62, p < 0.05). Higher native T1 times correlated with worse LV longitudinal (r = 0.50, p < 0.05) and mid short axis circumferential strain (r = 0.38, p < 0.05). As compared to controls, TOF patients did not express higher markers of diffuse fibrosis. Longer cardiopulmonary bypass and aortic cross clamp times at surgery as well as biventricular enlargement and reduced exercise tolerance are associated with markers of diffuse myocardial fibrosis after TOF repair. Female patients have higher markers of diffuse myocardial fibrosis than males.

  12. Haemodynamic effects of dual-chamber pacing versus ventricular pacing during a walk test in patients with depressed or normal left ventricular function

    Energy Technology Data Exchange (ETDEWEB)

    Ferro, Adele; Salvatore, Marco; Cuocolo, Alberto [University Federico II, Department of Biomorphological and Functional Sciences, Institute of Biostructure and Bioimages of the National Council of Research, Naples (Italy); Duilio, Carlo; Santomauro, Maurizio [University Federico II, Department of Clinical Medicine, Cardiovascular and Immunological Sciences, Naples (Italy)

    2005-09-01

    Dual-chamber rate-modulated pacing provides haemodynamic benefits compared with ventricular pacing at rest, but it is unclear whether this also holds true during physical exercise in patients with heart failure. This study assessed the haemodynamic response to a walk test during dual-chamber pacing and ventricular pacing in patients with depressed or normal left ventricular (LV) function. Twelve patients with an LV ejection fraction <50% and 11 patients with an LV ejection fraction {>=}50% underwent two randomised 6-min walk tests under dual-chamber rate-modulated pacing and ventricular pacing at a fixed rate of 70 beats/min. All patients had a dual-chamber pacemaker implanted for complete heart block. LV function was monitored by a radionuclide ambulatory system. In patients with depressed LV function, the change from dual-chamber pacing to ventricular pacing induced a decrease in end-systolic volume at the peak of the walk test (P<0.05), with no difference in end-diastolic volume. As a consequence, higher increases in LV ejection fraction (P<0.0001) and stroke volume (P<0.01) were observed during ventricular pacing. No difference in cardiac output was found between the two pacing modes. In patients with normal LV function, the change from dual-chamber pacing to ventricular pacing induced a significant decrease in cardiac output (P<0.005 at rest and P<0.05 at the peak of the walk test). Compared with dual-chamber rate-modulated pacing, ventricular pacing improves cardiac function and does not affect cardiac output during physical activity in patients with depressed LV function, whereas it impairs cardiac output in those with normal function. (orig.)

  13. Haemodynamic effects of dual-chamber pacing versus ventricular pacing during a walk test in patients with depressed or normal left ventricular function

    International Nuclear Information System (INIS)

    Ferro, Adele; Salvatore, Marco; Cuocolo, Alberto; Duilio, Carlo; Santomauro, Maurizio

    2005-01-01

    Dual-chamber rate-modulated pacing provides haemodynamic benefits compared with ventricular pacing at rest, but it is unclear whether this also holds true during physical exercise in patients with heart failure. This study assessed the haemodynamic response to a walk test during dual-chamber pacing and ventricular pacing in patients with depressed or normal left ventricular (LV) function. Twelve patients with an LV ejection fraction <50% and 11 patients with an LV ejection fraction ≥50% underwent two randomised 6-min walk tests under dual-chamber rate-modulated pacing and ventricular pacing at a fixed rate of 70 beats/min. All patients had a dual-chamber pacemaker implanted for complete heart block. LV function was monitored by a radionuclide ambulatory system. In patients with depressed LV function, the change from dual-chamber pacing to ventricular pacing induced a decrease in end-systolic volume at the peak of the walk test (P<0.05), with no difference in end-diastolic volume. As a consequence, higher increases in LV ejection fraction (P<0.0001) and stroke volume (P<0.01) were observed during ventricular pacing. No difference in cardiac output was found between the two pacing modes. In patients with normal LV function, the change from dual-chamber pacing to ventricular pacing induced a significant decrease in cardiac output (P<0.005 at rest and P<0.05 at the peak of the walk test). Compared with dual-chamber rate-modulated pacing, ventricular pacing improves cardiac function and does not affect cardiac output during physical activity in patients with depressed LV function, whereas it impairs cardiac output in those with normal function. (orig.)

  14. Evaluation of right and left ventricular function in the patients with myocardial infarction using quantitative radionuclide cardioangiography

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Uehara, Toshiisa; Hayashida, Kohei; Ohmine, Hiromi; Kozuka, Takahiro

    1984-01-01

    We evaluated right and left ventricular function in the case of myocardial infarction (MI) by radionuclide cardioangiography. The right and left ventricular ejection fraction (RVEF, LVEF) and ventricular volume (RVEDV, LVEDV) were calculated. And, phase and amplitude images were also obtained from gated blood pool scan. There were 60 cases of MI (35 anterior MI, 17 inferior MI and 8 right ventricular MI) and 10 normal cases. The LVEF was depressed in anterior MI (36 +- 14%) and RVEF was depressed in right ventricular MI (37 +- 5%). In addition, LVEDV was increased in anterior MI (163 +- 47 ml) and RVEDV increased in right ventricular MI (208 +- 33 ml), respectively. The amplitude of infarcted area was decreased. And the phase angle of LV was delayed in anterior MI and that of RV was delayed in right ventricular MI. Therefore, in the case of right ventricular MI, the depression of LVEF and RVEF was caused by the biventricular myocardial damage. And the cross talk phenomenon of biventricle was rarely observed, since the lung acts as the buffer between RV and LV. In conclusion, these noninvasive, methods provide useful information on the biventricular function in the case of myocardial infarction. (author)

  15. On the value of geometry-based models for left ventricular volumetry in magnetic resonance imaging and electron beam tomography: a Bland-Altman analysis

    International Nuclear Information System (INIS)

    Reiter, Gert; Reiter, Ursula; Rienmueller, Rainer; Gagarina, Nina; Ryabikin, Alexander

    2004-01-01

    Objective: Methodological comparison of ellipsoid model-based approaches and Simpson method to evaluate left ventricular volumetric parameters by magnetic resonance (MR) and electron beam tomography (EBT) and analysis of the origin of possible discrepancies. Methods and material: 100 subjects (87 patients, 13 healthy volunteers) were studied in MR in various cardiac views and EBT long axis view to determine left ventricular volumes and masses by applying (rotational) ellipsoid and Simpson model. Observer variation and method agreement was quantified by means of variance component and Bland-Altman analysis. Results: Simpson approach showed smaller observer variability than all ellipsoid approaches. All geometry-based models gave smaller left ventricular volumes than Simpson approach, the bias in mass determination was minimal. Whereas high correlation coefficients (typically 0.85-0.95) for left ventricular volume and mass measurements indicated satisfying correspondence between methods, large 95% limits of agreement made a transfer of results for single subjects between Simpson and ellipsoid approaches difficult and between different geometry-based models almost impossible. Because 95% limits of agreement and observer variability of geometry-based approaches were of equal order, the latter could be identified as main limiting factor of methodological agreement. Conclusion: MR Simpson approach is superior to all ellipsoid model-based approaches, because observer variability is smaller

  16. Response of left ventricular volume to exercise in man assessed by radionuclide equilibrium angiography

    International Nuclear Information System (INIS)

    Slutsky, R.; Karliner, J.; Ricci, D.; Schuler, G.; Pfisterer, M.; Peterson, K.; Ashburn, W.

    1979-01-01

    To assess the effects of exercise on left ventricular volumes we studied 10 normal men, 15 patients with coronary disease who developed angina pectoris during exercise, and 10 patients with known coronary disease who did not develop angina during exercise. Each subject performed supine bicycle exercise under a mobile, single-crystal scintillation camera until angina or fatigue occurred. Technetium-99m bound to human serum albumin was the imaging agent. Data were collected at rest and during the last 2 minutes of each 3-minute stage of exercise and for 10 minutes after exercise. Volumes were calculated by a new radionuclide technique that correlated well with cineangiography and is expressed in nondimensional units. In normal subjects, the end-diastolic volume (EDV) at rest was not different from that a peak exercise. The end-systolic volume (ESV) decreased at peak exercise. ESV decreased progressively in all but two of 30 exercise periods. Angina patients had a larger EDV at rest and during chest pain than normals. Angina patients increased their ESV during chest pain resulting in a decreased ejection fraction (EF). All angina patients had a higher ESV during chest pain than during the exercise stage before chest pain. As a group, patients who did not develop angina had a lower EDV at rest and peak exercise than those who did develop angina. We conclude: that the EF increases during exercise due to a decrease in ESV; that the EF in patients with angina decreases because of an increase in ESV; and that the EF in coronary disease patients without angina shows no change because there is no significant change in the ESV. Radionuclide equilibrium angiography may prove useful for assessing EF and volume changes in patients with coronary artery disease

  17. Passive and active ventricular elastances of the left ventricle

    Directory of Open Access Journals (Sweden)

    Ng Eddie YK

    2005-02-01

    Full Text Available Abstract Background Description of the heart as a pump has been dominated by models based on elastance and compliance. Here, we are presenting a somewhat new concept of time-varying passive and active elastance. The mathematical basis of time-varying elastance of the ventricle is presented. We have defined elastance in terms of the relationship between ventricular pressure and volume, as: dP = EdV + VdE, where E includes passive (Ep and active (Ea elastance. By incorporating this concept in left ventricular (LV models to simulate filling and systolic phases, we have obtained the time-varying expression for Ea and the LV-volume dependent expression for Ep. Methods and Results Using the patient's catheterization-ventriculogram data, the values of passive and active elastance are computed. Ea is expressed as: ; Epis represented as: . Ea is deemed to represent a measure of LV contractility. Hence, Peak dP/dt and ejection fraction (EF are computed from the monitored data and used as the traditional measures of LV contractility. When our computed peak active elastance (Ea,max is compared against these traditional indices by linear regression, a high degree of correlation is obtained. As regards Ep, it constitutes a volume-dependent stiffness property of the LV, and is deemed to represent resistance-to-filling. Conclusions Passive and active ventricular elastance formulae can be evaluated from a single-beat P-V data by means of a simple-to-apply LV model. The active elastance (Ea can be used to characterize the ventricle's contractile state, while passive elastance (Ep can represent a measure of resistance-to-filling.

  18. The Correlation between Left and Right Ventricular Ejection Fractions in Patients with Ischemic Heart Disease, Documented by Cardiac Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Ali Eshraghi

    2016-03-01

    Full Text Available Introduction: The correlation between right and left ventricular ejection fractions (RVEF and LVEF, respectively has been studied in only a small number of patients with a marked decrease in RVEF and LVEF. The aim of the present study was to compare LVEF and RVEF in patients with ischemic heart disease. RVEF and LVEF were measured by Cardiovascular Magnetic Resonance (CMR imaging. Materials and Methods: This observational study was done in Ghaem general hospital in 2014.  LVEF and RVEF were measured in a series of 33 patients with ischemic heart disease, undergoing CMR for the evaluation of myocardial viability. The correlation between RVEF and LVEF in patients with ischemic heart disease was studied, using Pearson product-moment correlation coefficient analysis.   This study was done in Ghaem general hospital in 2014 with simple sapling. Results: Right ventricular end diastolic volume (186.33±58.90 and left ventricular end diastolic volume (121.72±61.64 were significantly correlated (r=0.223, P=0.005. Moreover, there was a significant correlation between right ventricular end systolic volume (88.18±40.90 and left ventricular end systolic volume (140.96±35.33 (r=0.329, P=0.000. The most significant association was observed between RVEF and LVEF (r=0.913, P=0.000. Conclusion: Based on the findings, RVEF and LVEF were significantly correlated in patients with ischemic heart disease, although this association was not always present in all cardiac patients. The cause of this discrepancy is still unknown.

  19. Observations of super early left ventricular remodeling experimental myocardial infarction

    International Nuclear Information System (INIS)

    Zhang, C.G.; Jin, J.H.; Zhao, X.B.; Kang, C.S.; Liang, F.Y.; Yin, Z.M.; Liu, G.F.; Li, S.J.; Li, X.F.; Hu, G.; Qin, D.Z.; Song, L.Z.

    2004-01-01

    , the animals were euthanized and their hearts were examined for pathology. SPECT reconstruction parameters: Filter; Butterworth; cutoff 0.35 and order 5: filtered backprojection. Images: short axis, horizontal and vertical long axis. Data analysis: Quantitative analysis: Quantitative Gated SPECT (QGS) software was used for calculating the end diastolic volume (EDV), end systolic volume (ESV) and ejection fraction (EF) Data from 16 animals was used. Qualitative analysis was used to assess shape, size of entire left ventricle, and wall motion which data was from 15 dogs. Echocardiography: HP5500 color Doppler ultrasonography diagnosis system with 12 MHz was used for echocardiography. EDV, ESV and EF were calculated by Simpson's method. Statistics analysis: SPSS statistics software was used for all quantitative data analysis. Results: A typical defect with complete absence of wall motion was found at the apex in all dogs (GA and GB) after LAD ligation, beginning with the first acquisition. Post-operatively, EDV and ESV significantly increased compared with pre-operation values. EF significantly decreased post-operatively. The table below shows quantitative data obtained at the earliest time after ligation. EDV and ESV continued to increase during the 6 hours post-operatively, while EF was just the opposite, decreasing with time. Using continuous gated myocardial imaging, reperfusion was found in 10 dogs (62.5%) on the apex area at 1-3 hours after the defect was originally visualized, when a thinning wall could be seen on the apex defect area. By visual analysis we found structural characteristics of left ventricular remodeling, including infarct expansion with thinning (14/15 animals), lengthening (15/15), regional enlargement (9/15) and distortion (11/15). We also found remodeling of non-infarcted myocardium, including thickening (12/15) and lengthening (13/15) as well as global distortion of shape (15/15) and global ventricular dilatation (14/15). Statistical analysis

  20. Left ventricular time volume curve analysis in the detection of limited ischaemic heart disease

    International Nuclear Information System (INIS)

    Liechtenstein, M.; Blanchett, W.; Andrews, J.; Hunt, D.

    1982-01-01

    The aim of the study was to determine whether limited coronary artery disease (CAD) could be accurately detected using the Cardiac Gated Blood Pool (CGBP) scan with exercise. Regional left ventricular time volume curves (RLTVD) were generated from 52 studies (46 patients: 22 normals, 24 abnormals). The parameters assessed both globally and regionally and at rest (R) and exercise (Ex) were: (1) the ejection fraction (EF) (2) the change in ejection fraction from R to Ex (δEF) (3) an early contraction index (ECI) (4) a maximal emptying index (DR) and (5) a maximal refilling index (AR). After careful analysis of these parameters it was decided that our diagnostic criteria would rely on the following: (1) the EF at R and Ex (2) the δ EF (3) the ECI at Ex (4) the AR at Ex This study showed that both the sensitivity and the specificity of the CGBP scan can be improved considerably with the inclusion of RLTVC from the levels obtained when the EF parameters alone are considered. It is possible with this technique to accurately diagnose limited CAD. (Author)

  1. Relation between the left ventricular mass and the left coronary artery dimensions as determined by 16-channel multidetector CT: comparison between the normotensive group and the hypertensive group

    International Nuclear Information System (INIS)

    Kang, Doo Kyung; Park, Kyung Joo; Tahk, Seung Jea; Kim, Sun Yong

    2006-01-01

    The purpose of this study is to determine the left ventricular mass (LVM) and the left coronary artery dimension and to investigate the relationship between the two values in the normotensive group and hypertensive group with using 16-channel multidetector CT (MDCT). Among the patients who underwent a CT coronary angiogram procedure using 16-channel MDCT at Ajou University Hospital from October 2004 to February 2005, 33 patient became the subjects of this study. These 33 patients showed normal findings without calcification or stenosis of the coronary arteries. The total volume of the left ventricular wall was calculated using work-in-progress cardiac CT reconstruction software. The LVM could then be directly calculated by multiplying the left ventricular muscle volume by the myocardial tissue density, which was assumed to be 1.05 g/cm 3 . The coronary diameter was measured by a fixed threshold method from the transverse reformation images obtained along the long-axis of each coronary artery. We calculated the cross-sectional area (CSA) of the coronary arteries from the equation of π D2/4 (D = diameter). Regression analysis was performed for the relationship between LVM and the left coronary artery dimensions with using a linear least-squares method. Comparison between the normotensive group and the hypertensive group was done using the Student test. The average LVM was 127.9 ± 36.2 g (mean ± standard deviation) and the average left ventricular mass index (LVMI) was 74.7 ± 15.5 g in this study population. The average diameter of the coronary arteries was 4.38 ± 0.69 mm for the left coronary artery. In all the subjects (n = 33, r = 0.67, ρ = 0.000) and the normotensive group (n = 21, r = 0.68, ρ = 0.000), the LVM was significantly correlated with the CSA of the left coronary artery, but not in the hypertensive group (n= 12, r = 0.57, ρ = 0.062). In the hypertensive group, the CSA of the left coronary arteries per 100 g of muscle mass tended to decrease as

  2. Changes of left ventricular function at exercise after lung resection

    International Nuclear Information System (INIS)

    Fujisaki, Takashi; Gomibuchi, Makoto; Shoji, Tasuku

    1992-01-01

    To determine the effect of lung resection on left ventricular function, 29 surgical patients were examined by using a nuclear stethoscope as a non-invasive means for measuring ventricular function at exercise. Pre- and post-operative parameters were obtained at rest and exercise. At rest, postoperative stroke volume (SV), end-diastolic volume (EDV), ejection fraction (EF), and ejection rate (ER) were significantly decreased; heart rate (HR) was significantly increased; and both filling rate (FR) and cardiac output (CO) remained unchanged. At maximum exercise, postoperative EDV, SV, ER and FR were significantly decreased; and there was no significant difference in either HR or EF, resulting in a significantly decreased CO. A ratio of CO and FR at maximum exercise to at rest was significantly decreased after surgery, as compared with that before surgery. According to the number of lobe resection, similar findings for all parameters, except for EF, were observed in the group of two lobe or more resection (n=13); and only two parameters, ER and FR, had the same tendency as those mentioned above in the group of a single lobe resection (n=16). The age group of 60 years or less (n=14) had similar findings for all parameters. In the group of 65 years or more (n=10), resting HR after surgery was not different from that before surgery; and postoperative CO was significantly decreased at rest, but not different from preoperative value at maximum exercise. In conclusion, left ventricular function associated with lung resection is reflected by decreased EDV and SV resulting from reduced pre-load. These changes may be corrected at rest, but not corrected at maximum exercise, resulting in decreased CO. More noticeable decrease in EDV and SV seems to be associated with larger lung resection. In older patients, HR is not corrected well, resulting in a decrease in CO at rest. (N.K.)

  3. Assessment of left ventricular global function

    International Nuclear Information System (INIS)

    Breuel, H.-P.; Baehre, M.

    1985-01-01

    Radionuclide ventriculography (RNV), i.e. noninvasive evaluation of left venticular performance following the application of radionuclides has had a major impact on many aspects of cardiology and has proven its clinical value and reliability in the last few years. This article deals mainly with the changes in global left ventricular function. The clinical applications of RNV for coronary artery diseases and valvular heart diseases are described. (Auth.)

  4. Serial changes in anatomy and ventricular function on dual-source cardiac computed tomography after the Norwood procedure for hypoplastic left heart syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea, Republic of)

    2017-12-15

    Accurate evaluation of anatomy and ventricular function after the Norwood procedure in hypoplastic left heart syndrome is important for treatment planning and prognostication, but echocardiography and cardiac MRI have limitations. To assess serial changes in anatomy and ventricular function on dual-source cardiac CT after the Norwood procedure for hypoplastic left heart syndrome. In 14 consecutive patients with hypoplastic left heart syndrome, end-systolic and end-diastolic phase cardiac dual-source CT was performed before and early (average: 1 month) after the Norwood procedure, and repeated late (median: 4.5 months) after the Norwood procedure in six patients. Ventricular functional parameters and indexed morphological measurements including pulmonary artery size, right ventricular free wall thickness, and ascending aorta size on cardiac CT were compared between different time points. Moreover, morphological features including ventricular septal defect, endocardial fibroelastosis and coronary ventricular communication were evaluated on cardiac CT. Right ventricular function and volumes remained unchanged (indexed end-systolic and end-diastolic volumes: 38.9±14.0 vs. 41.1±21.5 ml/m{sup 2}, P=0.7 and 99.5±30.5 vs. 105.1±33.0 ml/m{sup 2}, P=0.6; ejection fraction: 60.1±7.3 vs. 63.8±7.0%, P=0.1, and indexed stroke volume: 60.7±18.0 vs. 64.0±15.6 ml/m{sup 2}, P=0.5) early after the Norwood procedure, but function was decreased (ejection fraction: 64.2±2.6 vs. 58.1±7.1%, P=0.01) and volume was increased (indexed end-systolic and end-diastolic volumes: 39.2±14.9 vs. 68.9±20.6 ml/m{sup 2}, P<0.003 and 107.8±36.5 vs. 162.9±36.2 ml/m{sup 2}, P<0.006, and indexed stroke volume: 68.6±21.7 vs. 94.0±21.3 ml/m{sup 2}, P=0.02) later. Branch pulmonary artery size showed a gradual decrease without asymmetry after the Norwood procedure. Right and left pulmonary artery stenoses were identified in 21.4% (3/14) of the patients. Indexed right ventricular free wall

  5. Rest and exercise ventricular function in adults with congenital ventricular septal defects

    International Nuclear Information System (INIS)

    Jablonsky, G.; Hilton, J.D.; Liu, P.P.; Morch, J.E.; Druck, M.N.; Bar-Shlomo, B.Z.; McLaughlin, P.R.

    1983-01-01

    Rest and exercise right and left ventricular function were compared using equilibrium gated radionuclide angiography in 19 normal sedentary control subjects and 34 patients with hemodynamically documented congenital ventricular septal defect (VSD). Gated radionuclide angiography was performed at rest and during each level of graded supine bicycle exercise to fatigue. Heart rate, blood pressure, maximal work load achieved, and right and left ventricular ejection fractions were assessed. The control subjects demonstrated an increase in both the left and right ventricular ejection fractions with exercise. All study groups failed to demonstrate an increase in ejection fraction in either ventricle with exercise. Furthermore, resting left ventricular ejection fraction in Groups 2 and 3 was lower than that in the control subjects and resting right ventricular ejection fraction was lower in Group 3 versus control subjects. Thus left and right ventricular function on exercise were abnormal in patients with residual VSD as compared with control subjects; rest and exercise left ventricular ejection fractions remained abnormal despite surgical closure of VSD in the remote past; resting left and right ventricular function was abnormal in patients with Eisenmenger's complex; lifelong volume overload may be detrimental to myocardial function

  6. Restoration of optimal ellipsoid left ventricular geometry: lessons learnt from in silico surgical modelling.

    Science.gov (United States)

    Adhyapak, Srilakshmi M; Menon, Prahlad G; Rao Parachuri, V

    2014-02-01

    Several issues that are inherent in the surgical techniques of surgical ventricular restoration (SVR) need specialized devices or techniques to overcome them, which may not always result in optimal outcomes. We used a non-invasive novel in silico modelling technique to study left ventricular (LV) morphology and function before and after SVR. The cardiac magnetic resonance imaging derived actual pre- and postoperative endocardial morphology and function was compared with the in silico analysis of the same. Cardiac magnetic resonance steady state free precession (SSFP) cine images were employed to segment endocardial surface contours over the cardiac cycle. Using the principle of Hausdorff distance to examine phase-to-phase regional endocardial displacement, dyskinetic/akinetic areas were identified at the instant of peak basal contraction velocity. Using a three-dimensional (3D) surface clipping tool, the maximally scarred, dyskinetic or akinetic LV antero-apical areas were virtually resected and a new apex was created. A virtual rectangular patch was created upon the clipped surface LV model by 3D Delaunay triangulation. Presurgical endocardial mechanical function quantified from cine cardiac magnetic resonance, using a technique of spherical harmonics (SPHARM) surface parameterization, was applied onto the virtually clipped and patched LV surface model. Finally, the in silico model of post-SVR LV shape was analysed for quantification of regional left ventricular volumes (RLVVs) and function. This was tested in 2 patients with post-myocardial infarction antero-apical LV aneuryms. Left ventricular mechanical dysynchrony was evaluated by RLVV analysis of pre-SVR, in silico post-SVR and actual post-SVR LV endocardial surface data. Following exclusion of the scarred areas, the virtual resected LV model demonstrated significantly lesser areas of akinesia. The decreases in regional LV volumes in the in silico modelling were significant and comparable with the actual

  7. Nonlinear isochrones in murine left ventricular pressure-volume loops: how well does the time-varying elastance concept hold?

    Science.gov (United States)

    Claessens, T E; Georgakopoulos, D; Afanasyeva, M; Vermeersch, S J; Millar, H D; Stergiopulos, N; Westerhof, N; Verdonck, P R; Segers, P

    2006-04-01

    The linear time-varying elastance theory is frequently used to describe the change in ventricular stiffness during the cardiac cycle. The concept assumes that all isochrones (i.e., curves that connect pressure-volume data occurring at the same time) are linear and have a common volume intercept. Of specific interest is the steepest isochrone, the end-systolic pressure-volume relationship (ESPVR), of which the slope serves as an index for cardiac contractile function. Pressure-volume measurements, achieved with a combined pressure-conductance catheter in the left ventricle of 13 open-chest anesthetized mice, showed a marked curvilinearity of the isochrones. We therefore analyzed the shape of the isochrones by using six regression algorithms (two linear, two quadratic, and two logarithmic, each with a fixed or time-varying intercept) and discussed the consequences for the elastance concept. Our main observations were 1) the volume intercept varies considerably with time; 2) isochrones are equally well described by using quadratic or logarithmic regression; 3) linear regression with a fixed intercept shows poor correlation (R(2) volume intercept of the ESPVR. In conclusion, the linear time-varying elastance fails to provide a sufficiently robust model to account for changes in pressure and volume during the cardiac cycle in the mouse ventricle. A new framework accounting for the nonlinear shape of the isochrones needs to be developed.

  8. Simultaneous determination of left ventricular perfusion and function

    International Nuclear Information System (INIS)

    Gremillet, E.; Champailler, A.; Esquerre, J.P.; Ouhayoun, E.; Coca, F.; Furber, A.; Le Jeune, J.J.

    1997-01-01

    Myocardial perfusion scintigraphy is a very useful tool for the diagnosis and prognosis of coronary artery disease. The evaluation of left ventricular function during stress testing in also very useful to determine the prognosis of coronary artery disease. This chapter highlights three different imaging methods to assess left ventricular function and myocardial perfusion/ The first one consists of sequential dual isotope myocardial SPECT with ECG-gating. The second concerns magnetic resonance imaging and the third explores first pass exercise ventriculography and myocardial perfusion scintigraphy simultaneously evaluated by means of 99m Tc-sestamibi. (authors)

  9. Right ventricular volume determination by two-dimensional echocardiography and radiography in model hearts using a subtraction method

    International Nuclear Information System (INIS)

    Krebs, W.; Erbel, R.; Schweizer, P.; Richter, H.A.; Massberg, I.; Meyer, J.; Effert, S.; Henn, G.

    1982-01-01

    The irregularity and complexity of the right ventricle is the reason why no accurate method for right ventricular volume determination exists. A new method for right ventricular volume determination particularly for two-dimensional echocardiography was developed - it is called subtraction method - and was compared with the pyramid and Simpson's methods. The partial volume of the left ventricle and septum was subtracted from total volume of right and left ventricle including interventricular septum. Thus right ventricular volume resulted. Total and partial volume were computer-assisted calculated by use of biplane methods, preferably Simpson's rule. The method was proved with thinwall silicon-rubber model hearts of the left and right ventricle. Two orthogonal planes in the long-axis were filmed by radiography or scanned in a water bath by two-dimensional echocardiography equivalent to RAO and LAO-projections of cineangiocardiograms or to four- and two-chamber views of apical two-dimensional echocardiograms. For calculation of the major axes of the elliptical sections, summed up by Simpson's rule, they were derived from the LAO-projection and the four-chamber view, respectively, the minor axis approximated from the RAO-projection and the two-chamber view. For comparison of direct-measured volume and two-dimensional echocardiographically determined volume, regression equation was given by y = 1.01 x - 3.2, correlation-coefficient, r = 0.977, and standard error of estimate (SEE) +-10.5 ml. For radiography, regression equation was y = 0.909 x + 13.3, r = 0.983, SEE = +-8.0 ml. For pyramid method and Simpson's rule, higher standard errors and lower correlation coefficients were found. Between radiography and two-dimensional echocardiography a mean difference of 4.3 +- 13.2 ml, using subtraction method, and -10.2 +- 22.9 ml, using pyramid method, as well as -0.6 +- 18.5 ml, using Simpson's rule, were calculated for right ventricular volume measurements. (orig./APR) [de

  10. The left ventricle as a mechanical engine: from Leonardo da Vinci to the echocardiographic assessment of peak power output-to-left ventricular mass.

    Science.gov (United States)

    Dini, Frank L; Guarini, Giacinta; Ballo, Piercarlo; Carluccio, Erberto; Maiello, Maria; Capozza, Paola; Innelli, Pasquale; Rosa, Gian M; Palmiero, Pasquale; Galderisi, Maurizio; Razzolini, Renato; Nodari, Savina

    2013-03-01

    The interpretation of the heart as a mechanical engine dates back to the teachings of Leonardo da Vinci, who was the first to apply the laws of mechanics to the function of the heart. Similar to any mechanical engine, whose performance is proportional to the power generated with respect to weight, the left ventricle can be viewed as a power generator whose performance can be related to left ventricular mass. Stress echocardiography may provide valuable information on the relationship between cardiac performance and recruited left ventricular mass that may be used in distinguishing between adaptive and maladaptive left ventricular remodeling. Peak power output-to-mass, obtained during exercise or pharmacological stress echocardiography, is a measure that reflects the number of watts that are developed by 100 g of left ventricular mass under maximal stimulation. Power output-to-mass may be calculated as left ventricular power output per 100 g of left ventricular mass: 100× left ventricular power output divided by left ventricular mass (W/100 g). A simplified formula to calculate power output-to-mass is as follows: 0.222 × cardiac output (l/min) × mean blood pressure (mmHg)/left ventricular mass (g). When the integrity of myocardial structure is compromised, a mismatch becomes apparent between maximal cardiac power output and left ventricular mass; when this occurs, a reduction of the peak power output-to-mass index is observed.

  11. Reversible left ventricular dysfunction - important clinical problem of contemporary cardiology

    International Nuclear Information System (INIS)

    Witkowski, A.

    1994-01-01

    An important clinical issue there is determination whether left ventricular damages are reversible or not single photon emission computed tomography and positron computed tomography techniques are shown to provide valuable data in this problem. Article describes basic syndromes connected with left ventricular dysfunction, namely: hibernating myocardium, stunned myocardium and ischemic myocardium preconditioning. (author). 18 refs

  12. Ethical challenges with the left ventricular assist device as a destination therapy

    Directory of Open Access Journals (Sweden)

    Rady Mohamed Y

    2008-08-01

    Full Text Available Abstract The left ventricular assist device was originally designed to be surgically implanted as a bridge to transplantation for patients with chronic end-stage heart failure. On the basis of the REMATCH trial, the US Food and Drug Administration and the US Centers for Medicare & Medicaid Services approved permanent implantation of the left ventricular assist device as a destination therapy in Medicare beneficiaries who are not candidates for heart transplantation. The use of the left ventricular assist device as a destination therapy raises certain ethical challenges. Left ventricular assist devices can prolong the survival of average recipients compared with optimal medical management of chronic end-stage heart failure. However, the overall quality of life can be adversely affected in some recipients because of serious infections, neurologic complications, and device malfunction. Left ventricular assist devices alter end-of-life trajectories. The caregivers of recipients may experience significant burden (e.g., poor physical health, depression, anxiety, and posttraumatic stress disorder from destination therapy with left ventricular assist devices. There are also social and financial ramifications for recipients and their families. We advocate early utilization of a palliative care approach and outline prerequisite conditions so that consenting for the use of a left ventricular assist device as a destination therapy is a well informed process. These conditions include: (1 direct participation of a multidisciplinary care team, including palliative care specialists, (2 a concise plan of care for anticipated device-related complications, (3 careful surveillance and counseling for caregiver burden, (4 advance-care planning for anticipated end-of-life trajectories and timing of device deactivation, and (5 a plan to address the long-term financial burden on patients, families, and caregivers. Short-term mechanical circulatory devices (e

  13. Relationship between obesity and left ventricular hypertrophy in children

    Directory of Open Access Journals (Sweden)

    Johnny Rompis

    2016-10-01

    Full Text Available Background Obesity is a chronic metabolic disorder associated with cardiovascular disease (CVD increasing morbidity-mortality rates. It is apparent that a variety of adaptations/alterations in cardiac structure and function occurs as excessive adipose tissue accumulates. This leads to a decrease in diastolic compliance, eventually resulting in an increase in left ventricular filling pressure and left ventricular enlargement. Objective To evaluate left ventricular hypertrophy (LVH among  obese using electrocardiographic (ECG criteria. Methods A cross-sectional study was conducted on 74 children aged 10-15 years from February 2009 to October 2009. The subjects were divided into obese and control groups. Physical examination and standard 12 lead electrocardiography (ECG were done in both groups. Results Of 37 obese children, LVH were featured in 3 subjects, while in control group, only 1 child had LVH (P= 0.304. We found that mean RV6 in obese and control group were 9.8446 (SD 3.5854 and 11.9662 (SD 3.2857, respectively (P=0.005. As an additional findings, we found that birth weight was related to obesity in children. Conclusion There is no relation between obesity and left ventricular using ECG criteria in obese children aged 10-15 years.

  14. Clinical value of regression of electrocardiographic left ventricular hypertrophy after aortic valve replacement.

    Science.gov (United States)

    Yamabe, Sayuri; Dohi, Yoshihiro; Higashi, Akifumi; Kinoshita, Hiroki; Sada, Yoshiharu; Hidaka, Takayuki; Kurisu, Satoshi; Shiode, Nobuo; Kihara, Yasuki

    2016-09-01

    Electrocardiographic left ventricular hypertrophy (ECG-LVH) gradually regressed after aortic valve replacement (AVR) in patients with severe aortic stenosis. Sokolow-Lyon voltage (SV1 + RV5/6) is possibly the most widely used criterion for ECG-LVH. The aim of this study was to determine whether decrease in Sokolow-Lyon voltage reflects left ventricular reverse remodeling detected by echocardiography after AVR. Of 129 consecutive patients who underwent AVR for severe aortic stenosis, 38 patients with preoperative ECG-LVH, defined by SV1 + RV5/6 of ≥3.5 mV, were enrolled in this study. Electrocardiography and echocardiography were performed preoperatively and 1 year postoperatively. The patients were divided into ECG-LVH regression group (n = 19) and non-regression group (n = 19) according to the median value of the absolute regression in SV1 + RV5/6. Multivariate logistic regression analysis was performed to assess determinants of ECG-LVH regression among echocardiographic indices. ECG-LVH regression group showed significantly greater decrease in left ventricular mass index and left ventricular dimensions than Non-regression group. ECG-LVH regression was independently determined by decrease in the left ventricular mass index [odds ratio (OR) 1.28, 95 % confidence interval (CI) 1.03-1.69, p = 0.048], left ventricular end-diastolic dimension (OR 1.18, 95 % CI 1.03-1.41, p = 0.014), and left ventricular end-systolic dimension (OR 1.24, 95 % CI 1.06-1.52, p = 0.0047). ECG-LVH regression could be a marker of the effect of AVR on both reducing the left ventricular mass index and left ventricular dimensions. The effect of AVR on reverse remodeling can be estimated, at least in part, by regression of ECG-LVH.

  15. Evaluation of changes in left ventricular structure and function in hypertensive patients with coronary artery disease after PCI using real-time three-dimensional echocardiography.

    Science.gov (United States)

    Meng, Yanhong; Zong, Ling; Zhang, Ziteng; Han, Youdong; Wang, Yanhui

    2018-02-01

    We aimed to evaluate the changes in left ventricular structure and function in hypertensive patients with coronary artery disease before and after percutaneous coronary intervention (PCI) using real-time three-dimensional echocardiography. Two hundred and eighty hypertensive patients with coronary artery disease undergoing PCI and 120 cases who did not receive PCI in our hospital were selected as the subjects of our study. All patients were administered with routine antiplatelet, anticoagulant, lipid-lowering, antihypertensive, dilating coronary artery and other medications. The left ventricular systolic function and systolic synchrony index changes before and after subjects were treated by PCI were analyzed using three-dimensional echocardiography. At 2 days before surgery, there were no significant differences in the left ventricular end-diastolic volume, left ventricular end-systolic volume (LVESV) and ejection fraction (EF) between the two patient groups (P>0.05). At 3 months and 9 months, the two key time points after PCI, the LVESV level in the PCI group was distinctly decreased, while EF was significantly increased (P0.05); however, the parameters of time from the corresponding segment of the myocardium to the minimal systolic volume in patients in the PCI group were significantly reduced at 3 and 9 months after surgery (PPCI accurately and in real-time, which may play a significant role.

  16. Left ventricular function abnormalities as a manifestation of silent myocardial ischemia.

    Science.gov (United States)

    Lambert, C R; Conti, C R; Pepine, C J

    1986-11-01

    A large body of evidence exists indicating that left ventricular dysfunction is a common occurrence in patients with severe coronary artery disease and represents silent or asymptomatic myocardial ischemia. Such dysfunction probably occurs early in the time course of every ischemic episode in patients with coronary artery disease whether symptoms are eventually manifested or not. The pathophysiology of silent versus symptomatic left ventricular dysfunction due to ischemia appears to be identical. Silent ischemia-related left ventricular dysfunction can be documented during spontaneous or stress-induced perturbations in the myocardial oxygen supply/demand ratio. It also may be detected by nitroglycerin-induced improvement in ventricular function or by salutary changes in wall motion following revascularization. Silent left ventricular dysfunction is a very early occurrence during ischemia and precedes electrocardiographic abnormalities. In this light, its existence should always be kept in mind when dealing with patients with ischemic heart disease. It can be hypothesized that because silent ischemia appears to be identical to ischemia with symptoms in a pathophysiologic sense, prognosis and treatment in both cases should be the same.

  17. Pulmonary thallium uptake: Correlation with systolic and diastolic left ventricular function at rest and during exercise

    International Nuclear Information System (INIS)

    Mannting, F.

    1990-01-01

    Quantified pulmonary 201-thallium uptake, assessed as pulmonary/myocardial ratios (PM) and body surface area-corrected absolute pulmonary uptake (Pc), was determined from single photon emission computed tomography studies in 22 normal subjects and 46 consecutive patients with coronary artery disease (CAD). By means of equilibrium radionuclide angiography (ERNA), ejection fraction (EF), peak ejection rate (PER) in end-diastolic volume (EDV/sec) and peak filling rate (PFR) in EDV/sec and stroke volume (SV/sec) units, PFR/PER ratio, and time to peak filling rate (TPFR) in milliseconds were computed at rest and during exercise (n = 35). Left ventricular response to exercise was assessed as delta EF, relative delta EF, delta EDV, and delta ESV. In normal subjects the PM ratios showed significant inverse correlation with PER at rest and with EF, PER, and PFRedv during exercise. For the left ventricular response to exercise, delta ESV showed significant correlation with the PM ratios. The body surface area-corrected pulmonary uptake values showed no correlation with any of the variables. In patients with CAD the PM ratios and Pc uptake showed significant inverse correlation with EF, PER, PFRedv and to exercise EF, exercise PER, and exercise PFRedv. For the left ventricular response to exercise, delta EF showed significant inverse correlation with the PM ratios but not with the Pc uptake. Neither in normal subjects nor in patients with CAD did any of the independent diastolic variables show significant correlation with the PM ratios or Pc values. Thus pulmonary thallium uptake is correlated with systolic left ventricular function at rest and during exercise in normal subjects and in patients with CAD but not with diastolic function. In normal subjects delta ESV and in patients with CAD, delta EF showed correlation with pulmonary thallium uptake

  18. Non-gated computed tomography of left ventricular hypertrophy

    International Nuclear Information System (INIS)

    Harada, Junta

    1983-01-01

    Non-ECG gated computed tomography (CT) of the heart was carried out in 19 cases with cardiovascular diseases; 4 with mitral stenosis, 3 with aortic valve disease, 2 with combined valve disease, 8 with hypertrophic cardiomyopathy and one myocardial infarction and one aortic aneurysm. All cardiac diseases were studied by echocardiography and 13 of them further investigated by intracadiac catheterization. The interventricular septum and the apical and posterolateral wall of the left ventricle were segmentally evaluated as to relative wall thickness of myocardium on CT. The wall thickness was directly measured on left ventricular cine angiograms in 13 cases. O-G vector calculated by CT was compatible with the palne of vectorcardiography in evaluating left ventricular hypertorphy. Conclusion were as follows: 1) The degree and site of myocardial hypertrophy were detected by CT with satisfaction. 2) The area of ventricular myocardium increased in aortic valve disease and hypertrophic cardiomyopathy. 3) The direction and magnitude of O-G vector calculated by CT were well correlated to the half area of QRS loop in horizontal plane of vectorcardiography. (author)

  19. Prediction of 6 months left ventricular dilatation after myocardial infarction in relation to cardiac morbidity and mortality - Application of a new dilatation model to GISSI-3 data

    NARCIS (Netherlands)

    de Kam, PJ; Nicolosi, GL; Voors, AA; van den Berg, MP; Brouwer, J; van Veldhuisen, DJ; Barlera, S; Maggioni, AP; Giannuzzi, P; Temporelli, PL; Latini, R; van Gilst, WH

    Aims To predict the long-term left ventricular volume index early after myocardial infarction and to investigate the relationship between long-term left ventricular dilatation risk and clinical outcome. Methods and Results By applying a previously developed dilatation model, we predicted the 6-month

  20. The influence of type 2 diabetes and gender on ventricular repolarization dispersion in patients with sub-clinic left ventricular diastolic dysfunction.

    Science.gov (United States)

    Jani, Ylber; Kamberi, Ahmet; Xhunga, Sotir; Pocesta, Bekim; Ferati, Fatmir; Lala, Dali; Zeqiri, Agim; Rexhepi, Atila

    2015-01-01

    To assess the influence of type 2 DM and gender, on the QT dispersion, Tpeak-Tend dispersion of ventricular repolarization, in patients with sub-clinic left ventricular diastolic dysfunction of the heart. QT dispersion, that reflects spatial inhomogeneity in ventricular repolarization, Tpeak-Tend dispersion, this on the other hand reflects transmural inhomogeneity in ventricular repolarization, that is increased in an early stage of cardiomyopathy, and in patients with left ventricular diastolic dysfunction, as well. The left ventricular diastolic dysfunction, a basic characteristic of diabetic heart disease (diabetic cardiomyopathy), that developes earlier than systolic dysfunction, suggests that diastolic markers might be sensitive for early cardiac injury. It is also demonstrated that gender has complex influence on indices of myocardial repolarization abnormalities such as QT interval and QT dispersion. We performed an observational study including 300 diabetic patients with similar epidemiological-demographic characteristics recruited in our institution from May 2009 to July 2014, divided into two groups. Demographic and laboratory echocardiographic data were obtained, twelve lead resting electrocardiography, QT, QTc, Tpeak-Tend-intervals and dispersion, were determined manually, and were compared between various groups. For statistical analysis a t-test, X(2) test, and logistic regression are used according to the type of variables. A p value <0.05 was considered statistically significant for a confidence interval of 95%. QTc max. interval, QTc dispersion and Tpeak-Tend dispersion, were significantly higher in diabetic group with subclinical LV (left ventricular) diastolic dysfunction, than in diabetic group with normal left ventricular diastolic function (445.24±14.7 ms vs. 433.55±14.4 ms, P<0.000; 44.98±18.78 ms vs. 32.05±17.9 ms, P<0.000; 32.60±1.6 ms vs. 17.46±2.0 ms, P<0.02. Prolonged QTc max. interval was found in 33% of patients, indiabetic group

  1. [Surgical treatment of congenital obstruction of the left ventricular outflow tract].

    Science.gov (United States)

    Biocina, B; Sutlić, Z; Husedinović, I; Letica, D; Sokolić, J

    1993-01-01

    This report presents the classification and all types of left ventricular outflow tract obstructions. The possibilities of operative therapies are surveyed as well. Results of surgical treatment in 34 patients with obstruction to left ventricular outflow are shown. The majority of patients underwent operation under extracorporeal circulation (84.4%), while the rest were operated by means of the inflow occlusion technique (14.7%). The obtained results were compared with those from the literature. The importance of echocardiographic evaluation of location of the left ventricular outflow tract obstruction and the appropriate choice of a surgical technique according to the patient's age are emphasized.

  2. Left ventricular hypertrophy in children, adolescents and young adults with sickle cell anemia

    Directory of Open Access Journals (Sweden)

    Gustavo Baptista de Almeida Faro

    2015-10-01

    Full Text Available OBJECTIVE: The aims of this study were to estimate the frequency of left ventricular hypertrophy and to identify variables associated with this condition in under 25-year-old patients with sickle cell anemia.METHODS: A cross-sectional study was performed of children, adolescents and young adults with sickle cell anemia submitted to a transthoracic Doppler echocardiography. The mass of the left ventricle was determined by the formula of Devereux et al. with correction for height, and the percentile curves of gender and age were applied. Individuals with rheumatic and congenital heart disease were excluded. The patients were divided into two groups according to the presence or absence of left ventricular hypertrophy and compared according to clinical, echocardiographic and laboratory variables.RESULTS: A total of 37.6% of the patients had left ventricular hypertrophy in this sample. There was no difference between the groups of patients with and without hypertrophy according to pathological history or clinical characteristics, except possibly for the use of hydroxyurea, more often used in the group without left ventricular hypertrophy. Patients with left ventricular hypertrophy presented larger left atria and lower hemoglobin and hematocrit levels, reticulocyte index and a higher albumin:creatinine ratio in urine.CONCLUSION: Left ventricular hypertrophy was observed in more than one-third of the young patients with sickle cell anemia with this finding being inversely correlated to the hemoglobin and hematocrit levels, and reticulocyte index and directly associated to a higher albumin/creatinine ratio. It is possible that hydroxyurea had had a protective effect on the development of left ventricular hypertrophy.

  3. Effect of food intake on left ventricular wall stress

    OpenAIRE

    Gårdinger, Ylva; Hlebowicz, Joanna; Björgell, Ola; Dencker, Magnus

    2014-01-01

    Objective: Left ventricular wall stress has been investigated in a variety of populations, but the effect of food intake has not been evaluated. We assessed whether left ventricular wall stress is affected by food intake in healthy subjects. Methods: Twenty-three healthy subjects aged 25.6 +/- 4.5 years were investigated. Meridional end-systolic wall stress (ESS) and circumferential end-systolic wall stress (cESS) were measured before, 30 minutes after, and 110 minutes after a standardised me...

  4. Calculation of cardiac pressures using left ventricular ejection fraction (LVEF) derived from radionuclide angiography

    International Nuclear Information System (INIS)

    Hommer, E.

    1981-01-01

    An attempt has been made to develop formulas to determine cardiac pressures in an undisturbed flow in patients without valvular or shunt diseases. These are based entirely on the results of left ventricular ejection fraction rates, permitting pressure analysis of several compartments at the same tine. According to BORER et al. they also enable determination of left ventricular 'Functional Reserve' after bycycle exercise as well as left ventricular 'Relaxation Reserve'. They support the views of NYHA in determining the grades of cardiac insufficiency proving the system- and low-pressure participation. A single formula for pulmonary flow can determine the pulmonary arterial pressure. The left ventricular enddiastolic pressure can also be exclusively calculated by values of left ventricular functions, thus both formulas may be used in disorders of the mitral valves. The possibility to calculate pressures of all the compartments of the heart from left ventricular ejection rate shows, that in undisturbed flow global heart function depends on left ventricular function. Therefore the mutual dependence of these formulas presents an intercompartimental pressure regulation of the heart through pulmonary flow and pulmonary vascular pressure, which leaves an aspect of autonomous cardiac regulation open to discussion. (orig.) [de

  5. Correlation between left ventricular diastolic function before and after valve replacement surgery and myocardial ultrastructural changes in patients with left ventricular volume-overloaded valvular heart diseases

    International Nuclear Information System (INIS)

    Okada, Tomiro

    1993-01-01

    Left ventricular (LV) diastolic functions in 23 patients with aortic regurgitation (AR) and 22 patients with mitral regurgitation (MR) were evaluated by gated blood pool scintigraphy. LV myocardial biopsy was performed during open heart surgery, and LV myocardial ultrastructural changes were evaluated by electron microscope. Correlation between LV diastolic function and myocardial ultrastructural changes was examined. It was suggested that preoperative LV diastolic dysfunction occurred earlier than LV systolic dysfunction in patients with AR and MR. LV early diastolic dysfunction was especially significant in patients with AR. LV systolic function was significantly improved postoperatively compared with LV diastolic function in patients with AR and MR. It was suggested that LV interstitial fibrosis caused LV diastolic dysfunction in patients with AR and MR, and insufficiency of myocardial thickening as compensation in patients with MR. It was presumed that LV diastolic dysfunction was irreversible in patients with AR and MR in the distant postoperative period due to persistence of the preoperative myocardial ultrastructural change, e.g., interstitial fibrosis. These LV diastolic indices measured by gated pool scintigraphy were useful in predicting LV ultrastructural changes and postoperative LV dysfunction in patients with LV volume-overloaded valvular heart disease. (author)

  6. Value of the radiological study of the thorax for diagnosing left ventricular dysfunction in Chagas' disease

    Directory of Open Access Journals (Sweden)

    Perez Amanda Arantes

    2003-01-01

    Full Text Available OBJECTIVE: To determine the value of the radiological study of the thorax for diagnosing left ventricular dilation and left ventricular systolic dysfunction in patients with Chagas' disease. METHODS: A cross-sectional study of 166 consecutive patients with Chagas' disease and no other associated diseases. The patients underwent cardiac assessment with chest radiography and Doppler echocardiography. Sensitivity, specificity, and positive and negative predictive values of chest radiography were calculated to detect left ventricular dysfunction and the accuracy of the cardiothoracic ratio in the diagnosis of left ventricular dysfunction with the area below the ROC curve. The cardiothoracic ratio was correlated with the left ventricular ejection fraction and the left ventricular diastolic diameter. RESULTS: The abnormal chest radiogram had a sensitivity of 50%, specificity of 80.5%, and positive and negative predictive values of 51.2% and 79.8%, respectively, in the diagnosis of left ventricular dysfunction. The cardiothoracic ratio showed a weak correlation with left ventricular ejection fraction (r=-0.23 and left ventricular diastolic diameter (r=0.30. The area calculated under the ROC curve was 0.734. CONCLUSION: The radiological study of the thorax is not an accurate indicator of left ventricular dysfunction; its use as a screening method to initially approach the patient with Chagas' disease should be reevaluated.

  7. Percutaneous Repair of Postoperative Mitral Regurgitation After Left Ventricular Assist Device Implant.

    Science.gov (United States)

    Cork, David P; Adamson, Robert; Gollapudi, Raghava; Dembitsky, Walter; Jaski, Brian

    2018-02-01

    Mitral regurgitation commonly improves after implantation of a left ventricular assist device without concomitant valvular repair owing to the mechanical unloading of the left ventricle. However, the development (or persistence) of significant mitral regurgitation after implantation of a left ventricular assist device is associated with adverse clinical events. We present a case of a left ventricular assist device patient who successfully underwent a percutaneous MitraClip procedure for repair of persistent late postoperative mitral insufficiency with demonstrable clinical and hemodynamic improvement. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Current status of ultrafast CT to evaluate the left ventricle

    International Nuclear Information System (INIS)

    MacMillan, R.M.; Rees, M.R.; Maranhao, V.

    1987-01-01

    Contrast-enhanced ultrafast CT with the cine mode can enable reliable assessment of left ventricular mass and function. Two oblique planar views, the long axis and short axis, are required. Right and left ventricular end-diastolic volumes, end-systolic volumes, stroke volume and ejection fraction, left ventricular segmental wall motion, and left ventricular mass can be measured. This exhibit emphasizes the methods and pitfalls in acquiring this information. Results from the authors' studies thus far to validate these measurements against reference standards are reviewed

  9. The effect of acute mechanical left ventricular unloading on ovine tricuspid annular size and geometry.

    Science.gov (United States)

    Malinowski, Marcin; Wilton, Penny; Khaghani, Asghar; Brown, Michael; Langholz, David; Hooker, Victoria; Eberhart, Lenora; Hooker, Robert L; Timek, Tomasz A

    2016-09-01

    Left ventricular assist device (LVAD) implantation may alter right ventricular shape and function and lead to tricuspid regurgitation. This in turn has been reported to be a determinant of right ventricular (RV) failure after LVAD implantation, but the effect of mechanical left ventricular (LV) unloading on the tricuspid annulus is unknown. The aim of the study was to provide insight into the effect of LVAD support on tricuspid annular geometry and dynamics that may help to optimize LV unloading with the least deleterious effect on the right-sided geometry. In seven open-chest anaesthetized sheep, nine sonomicrometry crystals were implanted on the right ventricle. Additional nine crystals were implanted around the tricuspid annulus, with one crystal at each commissure defining three separate annular regions: anterior, posterior and septal. Left ventricular unloading was achieved by connecting a cannula in the left atrium and the aorta to a continuous-flow pump. The pump was used for 15 min at a full flow of 3.8 ± 0.3 l/min. Epicardial echocardiography was used to assess the degree of tricuspid insufficiency. Haemodynamic, echocardiographic and sonomicrometry data were collected before and during full unloading. Tricuspid annular area, and the regional and total perimeter were calculated from crystal coordinates, while 3D annular geometry was expressed as the orthogonal distance of each annular crystal to the least squares plane of all annular crystals. There was no significant tricuspid regurgitation observed either before or during LV unloading. Right ventricular free wall to septum diameter increased significantly at end-diastole during unloading from 23.6 ± 5.8 to 26.3 ± 6.5 mm (P = 0.009), but the right ventricular volume, tricuspid annular area and total perimeter did not change from baseline. However, the septal part of the annulus significantly decreased its maximal length (38.6 ± 8.1 to 37.9 ± 8.2 mm, P = 0.03). Annular contraction was not altered. The

  10. Hypertension and left ventricular hypertrophy in liquidators of consequences of the Chernobyl nuclear accident

    International Nuclear Information System (INIS)

    Shal'nova, S.A.; Smolenskij, A.V.; Shamarin, V.M.; Ehktova, T.V.; Berzak, N.V.; Zemtsova, N.A.; Timofeeva, S.G.; Zhavoronkova, E.A.; Muromtseva, G.A.; Arkad'eva, M.A.; Deev, A.D.

    1998-01-01

    Echocardiography was used for the study of prevalence of left ventricular hypertrophy in 839 liquidators of consequences of the Chernobyl accident. Prevalence of left ventricular hypertrophy (left ventricular myocardial mass 134 g/m 2 ) was 10.3, 13.4 and 22.5 % in liquidators with normal blood pressure, borderline hypertension and hypertension, respectively. Liquidators with normal blood pressure had significantly greater left ventricular myocardial mass than normotensive men from general population while liquidators and non liquidators with hypertension had equal values of this parameter [ru

  11. Evaluation of ECG-gated [(11)C]acetate PET for measuring left ventricular volumes, mass, and myocardial external efficiency.

    Science.gov (United States)

    Hansson, Nils Henrik; Tolbod, Lars; Harms, Johannes; Wiggers, Henrik; Kim, Won Yong; Hansen, Esben; Zaremba, Tomas; Frøkiær, Jørgen; Jakobsen, Steen; Sørensen, Jens

    2016-08-01

    Noninvasive estimation of myocardial external efficiency (MEE) requires measurements of left ventricular (LV) oxygen consumption with [(11)C]acetate PET in addition to LV stroke volume and mass with cardiovascular magnetic resonance (CMR). Measuring LV geometry directly from ECG-gated [(11)C]acetate PET might enable MEE evaluation from a single PET scan. Therefore, we sought to establish the accuracy of measuring LV volumes, mass, and MEE directly from ECG-gated [(11)C]acetate PET. Thirty-five subjects with aortic valve stenosis underwent ECG-gated [(11)C]acetate PET and CMR. List mode PET data were rebinned into 16-bin ECG-gated uptake images before measuring LV volumes and mass using commercial software and compared to CMR. Dynamic datasets were used for calculation of mean LV oxygen consumption and MEE. LV mass, volumes, and ejection fraction measured by CMR and PET correlated strongly (r = 0.86-0.92, P PET (P PET-based MEE, corrected for bias, correlated fairly with PET/CMR-based MEE (r = 0.60, P PET-based MEE bias was strongly associated with LV wall thickness. Although analysis-related improvements in accuracy are recommended, LV geometry estimated from ECG-gated [(11)C]acetate PET correlate excellently with CMR and can indeed be used to evaluate MEE.

  12. Pattern of left ventricular geometry in hypertension: a study of a ...

    African Journals Online (AJOL)

    Background: Hypertension is a leading cause of cardioxasular morbidity and mortality in Nigeria. The main aim of this study was to deterine the prevalence of left ventricular hypertrophy and left ventricular geometric patterns among hypertensives in Kano, Nigeria. Methods: The study was cross-sectional in design, and ...

  13. Four cases of right ventricular dysplasia

    International Nuclear Information System (INIS)

    Takamura, Ichiro; Ando, Joji; Miyamoto, Atsushi; Kobayashi, Takeshi; Sakamoto, Sanya; Yasuda, Hisakazu

    1985-01-01

    Finding of 81 Kr right ventriculography and 201 Tl myocardial perfusion imaging in 4 patients with right ventricular dysplasia (RVD) were compared with those in 28 patients with dilated cardiomyopathy. Remarkably dilated right ventricle was detected on 201 Tl myocardial perfusion imaging in the RVD group. In a patient with RVD who died suddenly, perfusion defect of the left ventricular myocardium, a decreased right ventricular ejection fraction, and an increased right ventricular end diastolic volume were seen. Perfusion defect of the left ventricular myocardium was seen in 10 of the 28 patients with dilated cardiomyopathy, 4 of whom died suddenly. In these 4 patients, a decreased left ventricular ejection fraction and an increased right ventricular end diastolic volume were seen. These findings obtained by the radionuclide techniques suggested that there are differences in cardiac dysfunction of the both ventricles between the groups with RVD and dilated cardiomyopathy. (Namekawa, K.)

  14. Left ventricular assist device implantation via left thoracotomy: alternative to repeat sternotomy.

    Science.gov (United States)

    Pierson, Richard N; Howser, Renee; Donaldson, Terri; Merrill, Walter H; Dignan, Rebecca J; Drinkwater, Davis C; Christian, Karla G; Butler, Javed; Chomsky, Don; Wilson, John R; Clark, Rick; Davis, Stacy F

    2002-03-01

    Repeat sternotomy for left ventricular assist device insertion may result in injury to the right heart or patent coronary grafts, complicating intraoperative and postoperative management. In 4 critically ill patients, left thoracotomy was used as an alternative to repeat sternotomy. Anastomosis of the outflow conduit to the descending thoracic aorta provided satisfactory hemodynamic support.

  15. Echocardiographic predictors of early in-hospital heart failure during first ST-elevation acute myocardial infarction: does myocardial performance index and left atrial volume improve diagnosis over conventional parameters of left ventricular function?

    Directory of Open Access Journals (Sweden)

    Machado Cristiano V

    2011-06-01

    Full Text Available Abstract Background Left ventricular ejection fraction (LVEF has been considered a major determinant of early outcome in acute myocardial infarction (AMI. Myocardial performance index (MPI has been associated to early evolution in AMI in a heterogeneous population, including non ST-elevation or previous AMI. Left atrial volume has been related with late evolution after AMI. We evaluated the independent role of clinical and echocardiographic variables including LVEF, MPI and left atrial volume in predicting early in-hospital congestive heart failure (CHF specifically in patients with a first isolated ST-elevation AMI. Methods Echocardiography was performed within 30 hours of chest pain in 95 patients with a first ST-elevation AMI followed during the first week of hospitalization. Several clinical and echocardiographic variables were analyzed. CHF was defined as Killip class ≥ II. Multivariate regression analysis was used to select independent predictor of in-hospital CHF. Results Early in-hospital CHF occurred in 29 (31% of patients. LVEF ≤ 0.45 was the single independent and highly significant predictor of early CHF among other clinical and echocardiographic variables (odds ratio 17.0; [95% CI 4.1 - 70.8]; p Conclusion For patients with first, isolated ST-elevation AMI, LVEF assessed by echocardiography still constitutes a strong and accurate independent predictor of early in-hospital CHF, superior to isolated MPI and left atrial volume in this particular subset of patients.

  16. Echocardiographic assessment of fetal left ventricular function in hypertensive disorder of pregnancy

    International Nuclear Information System (INIS)

    Liu Xiaozhen; Liu Shaozhong

    2011-01-01

    Objective: To investigate fetal left ventricular function in hypertensive disorder of pregnancy (HDP). Methods: Fetuses of hypertensive (84) and normotensive (147) mothers were enrolled in this study. The fetal left ventricular ejection fractions, E/A ratios of mitral valves, left atrial shortening fractions and Tei indexes of the two groups were measured on fetal echocardiography. Results: The left ventricular ejection fractions (P=0.040), E/A ratios of the mitral valves (P=0.042) and the left atrial shortening fractions (P=0.036) in fetuses of HDP were significantly smaller than those of the normal group whereas the Tei indexes (P=0.030) were significantly larger than those of the normal group. Conclusion: The hypertensive disorder of pregnancy may cause decreased systolic, diastolic and global function of the fetal left ventricle. (authors)

  17. Left ventricular heart failure and pulmonary hypertension†

    Science.gov (United States)

    Rosenkranz, Stephan; Gibbs, J. Simon R.; Wachter, Rolf; De Marco, Teresa; Vonk-Noordegraaf, Anton; Vachiéry, Jean-Luc

    2016-01-01

    Abstract In patients with left ventricular heart failure (HF), the development of pulmonary hypertension (PH) and right ventricular (RV) dysfunction are frequent and have important impact on disease progression, morbidity, and mortality, and therefore warrant clinical attention. Pulmonary hypertension related to left heart disease (LHD) by far represents the most common form of PH, accounting for 65–80% of cases. The proper distinction between pulmonary arterial hypertension and PH-LHD may be challenging, yet it has direct therapeutic consequences. Despite recent advances in the pathophysiological understanding and clinical assessment, and adjustments in the haemodynamic definitions and classification of PH-LHD, the haemodynamic interrelations in combined post- and pre-capillary PH are complex, definitions and prognostic significance of haemodynamic variables characterizing the degree of pre-capillary PH in LHD remain suboptimal, and there are currently no evidence-based recommendations for the management of PH-LHD. Here, we highlight the prevalence and significance of PH and RV dysfunction in patients with both HF with reduced ejection fraction (HFrEF) and HF with preserved ejection fraction (HFpEF), and provide insights into the complex pathophysiology of cardiopulmonary interaction in LHD, which may lead to the evolution from a ‘left ventricular phenotype’ to a ‘right ventricular phenotype’ across the natural history of HF. Furthermore, we propose to better define the individual phenotype of PH by integrating the clinical context, non-invasive assessment, and invasive haemodynamic variables in a structured diagnostic work-up. Finally, we challenge current definitions and diagnostic short falls, and discuss gaps in evidence, therapeutic options and the necessity for future developments in this context. PMID:26508169

  18. Impact of Aortic Valve Replacement on Left Ventricular Remodeling in Patients with Severe Aortic Stenosis and Severe Left Ventricular Dysfunction

    Directory of Open Access Journals (Sweden)

    Abderrahmane Bakkali

    2016-12-01

    Full Text Available Objective: The aim of this study was to evaluate the effect of aortic valve replacement on left ventricular function and remodeling among patients with severe aortic stenosis and severe left ventricular dysfunction. Methods: In this retrospective bicentric study extended over a 15-year period, 61 consecutive patients underwent isolated AVR for severe AS associated to reduced LV function. The mean age was 58.21 ± 12.50 years and 83.60 % were men. 70.50% of patients were in class III or IV NYHA. The mean left ventricular ejection fraction (LVEF was 32.9 ± 5.6.The mean LVEDD and LVESD were respectively 63.6 ± 9.2 and 50.2 ± 8.8 mm. The mean calculated logistic EuroScore was 12.2 ±4.5. Results: The hospital mortality was 11.5%. Morbidity was marked mainly by low output syndrome in 40.8% of cases. After a median follow-up of 38 months we have recorded 3 deaths. Almost all survivors were in class I and II of NYHA. The mean LV end-diastolic and end-systolic diameters decreased significantly at late postoperative stage. The mean LV ejection fraction increased significantly from 32.9 ± 5.6 to 38.2 ± 9.3 and to 50.3 ± 9.6 in early and late postoperative stages, respectively. Multivariate linear regression analysis found that increased early postoperative LVEF (β= 0.44, 95% CI [0.14; 0.75], p=0.006 and low mean transprosthesis gradient (β=-0.72, 95% CI [-1.42; -0.02], p= 0.04 were the independent predictors of left ventricular systolic function recovery. Conclusion: Patients with aortic valve stenosis and impaired LV systolic function benefited from AVR as regard improvement of LV function parameters and regression of the LV diameters .This improvement depends mainly on early postoperative LVEF and mean transprosthesis gradient.

  19. Clustering Of Left Ventricular Wall Motion Patterns

    Science.gov (United States)

    Bjelogrlic, Z.; Jakopin, J.; Gyergyek, L.

    1982-11-01

    A method for detection of wall regions with similar motion was presented. A model based on local direction information was used to measure the left ventricular wall motion from cineangiographic sequence. Three time functions were used to define segmental motion patterns: distance of a ventricular contour segment from the mean contour, the velocity of a segment and its acceleration. Motion patterns were clustered by the UPGMA algorithm and by an algorithm based on K-nearest neighboor classification rule.

  20. The influence of type 2 diabetes and gender on ventricular repolarization dispersion in patients with sub-clinic left ventricular diastolic dysfunction

    Science.gov (United States)

    Jani, Ylber; Kamberi, Ahmet; Xhunga, Sotir; Pocesta, Bekim; Ferati, Fatmir; Lala, Dali; Zeqiri, Agim; Rexhepi, Atila

    2015-01-01

    Objective: To assess the influence of type 2 DM and gender, on the QT dispersion, Tpeak-Tend dispersion of ventricular repolarization, in patients with sub-clinic left ventricular diastolic dysfunction of the heart. Background: QT dispersion, that reflects spatial inhomogeneity in ventricular repolarization, Tpeak-Tend dispersion, this on the other hand reflects transmural inhomogeneity in ventricular repolarization, that is increased in an early stage of cardiomyopathy, and in patients with left ventricular diastolic dysfunction, as well. The left ventricular diastolic dysfunction, a basic characteristic of diabetic heart disease (diabetic cardiomyopathy), that developes earlier than systolic dysfunction, suggests that diastolic markers might be sensitive for early cardiac injury. It is also demonstrated that gender has complex influence on indices of myocardial repolarization abnormalities such as QT interval and QT dispersion. Material and methods: We performed an observational study including 300 diabetic patients with similar epidemiological-demographic characteristics recruited in our institution from May 2009 to July 2014, divided into two groups. Demographic and laboratory echocardiographic data were obtained, twelve lead resting electrocardiography, QT, QTc, Tpeak-Tend-intervals and dispersion, were determined manually, and were compared between various groups. For statistical analysis a t-test, X2 test, and logistic regression are used according to the type of variables. A p value <0.05 was considered statistically significant for a confidence interval of 95%. Results: QTc max. interval, QTc dispersion and Tpeak-Tend dispersion, were significantly higher in diabetic group with subclinical LV (left ventricular) diastolic dysfunction, than in diabetic group with normal left ventricular diastolic function (445.24±14.7 ms vs. 433.55±14.4 ms, P<0.000; 44.98±18.78 ms vs. 32.05±17.9 ms, P<0.000; 32.60±1.6 ms vs. 17.46±2.0 ms, P<0.02. Prolonged QTc max

  1. Usefulness of {sup 201}Tl myocardial perfusion SPECT in prediction of left ventricular remodeling following an acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Seok Nam; Park, C. H.; Hwang, Kyung Hoon [Ajou Univ. College of Medicine, Suwon (Korea, Republic of)

    2000-02-01

    We investigated the role of myocardial perfusion SPECT in prediction of ventricular dilatation and the role of revascularization including thrombolytic therapy and PTCA in prevention of ventricular dilatation after an acute myocardial linfarction (AMI). We performed dipyridamole stress, 4 hour redistribution, and 24 hour reinjection Tl-201 SPECT in 6 patients with AMI two to nine days after attack. Perfusion and wall motion abnormalities were quantified by perfusion index(PI) and wall motion index (WMI). Left ventricular ejection fraction (LVEF), WMI and ventricular volume were measured within 1 week of AMI and after average of 6 months. According to serial changes of left ventricular end-diastolic volume (LVEDV), patients were divided into two groups. We compared WMI, PI and LVEF between the two groups. Relationships among degree of volume, stress-rest PI, WMI, CKMB,Q wave, LVEF and revascularization were analysed using multivariate analysis. Only initial rest perfusion index was significantly different between the two groups (p<0.05). While initial LVEF, stress PI, CKMB, trial of revascularization procedure, presence of Q wave and WMI were not significantly different between the two groups. Eight of 16 patients (50%) showed LV dilatation on follow-up echocardiography. Three of 3 patients (100%) who did not undergo revascualrization procedure documented LV dilatation. And only 5 (38%) of the remaining 13 patients who underwent revascularization revealed LV dilatation. There was no difference in infarct location between the two groups. By multivariate linear regression analysis in patients only undergoing revascularization, rest perfusion index was the only significant factor. Myocardial perfusion SPECT performed prior to revascularization was useful in prediction of LV dilatation after an AMI. Rest perfusion index on myocardial perfusion plays as a significant predictor of left ventricular dilatation after AMI. And revascularization appears to be a valuable

  2. Contrast media for left ventricular angiography. A comparison between Cardio-Conray and iopamidol.

    OpenAIRE

    Gwilt, D J; Nagle, R E

    1984-01-01

    Forty consecutive patients with coronary artery disease undergoing left ventricular angiography took part in a randomised double blind trial comparing a conventional contrast medium sodium meglumine iothalamate (Cardio-Conray) with the low osmolar agent iopamidol. Iopamidol produced a smaller rise in heart rate and a smaller fall in left ventricular systolic pressure, but the changes in left ventricular and diastolic pressure and maximum rate of change of pressure (dP/dt max) were not differe...

  3. Interaction of Left Ventricular Remodeling and Regional Dyssynchrony on Long-Term Prognosis after Cardiac Resynchronization Therapy

    DEFF Research Database (Denmark)

    Tayal, Bhupendar; Sogaard, Peter; Delgado-Montero, Antonia

    2017-01-01

    BACKGROUND: Left ventricular (LV) remodeling in heart failure (HF) manifested by chamber dilatation is associated with worse clinical outcomes. However, the impact of LV dilatation on the association of measures of dyssynchrony with long-term prognosis and resynchronization potential after cardiac...... resynchronization therapy (CRT) remains unclear. METHODS: Two hundred sixty CRT patients in New York Heart Association classes II to IV, with ejection fractions ≤ 35% and QRS intervals ≥ 120 msec, were prospectively studied. Quantitative echocardiographic assessment of LV volumes and mechanical dyssynchrony...... of the baseline indexed LV end-diastolic volume (EDVI). Patients with less dilated left ventricles (EDVI left ventricles (EDVI ≥ 90 mL/m(2)) for both primary (adjusted hazard ratio [HR], 2.20; 95% CI, 1.44-3.38; P

  4. Interaction of Left Ventricular Size and Sex on Outcome of Cardiac Resynchronization Therapy Among Patients With a Narrow QRS Duration in the EchoCRT Trial

    DEFF Research Database (Denmark)

    Varma, Niraj; Sogaard, Peter; Bax, Jeroen J

    2018-01-01

    BACKGROUND: Longer QRS duration (QRSd) improves, but increased left ventricular (LV) end-diastolic volume (LVEDV) reduces, efficacy of cardiac resynchronization therapy (CRT). QRSd/LVEDV ratios differ between sexes. We hypothesized that in the EchoCRT (Echocardiography Guided Cardiac Resynchroniz......BACKGROUND: Longer QRS duration (QRSd) improves, but increased left ventricular (LV) end-diastolic volume (LVEDV) reduces, efficacy of cardiac resynchronization therapy (CRT). QRSd/LVEDV ratios differ between sexes. We hypothesized that in the EchoCRT (Echocardiography Guided Cardiac...... Resynchronization Therapy) trial enrolling patients with heart failure with QRSd New York Heart Association class III, QRSd

  5. Assessment of left ventricular function in patients with atrial fibrillation by left ventricular filling and function curves determined by ECG gated blood pool scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Suetsugu

    1986-06-01

    Accurate cardiac function in patients with atrial fibrillation (Af) is difficult to assess, since a wide fluctuation of cardiac cycle makes the ventricular hemodynamics variable. Although ECG gated blood pool scintigraphy (EGBPS) is useful to evaluate left ventricular (LV) function, a conventional EGBPS might have a problem in applying to Af. Therefore, a new processing algorithm was devised to make multiple gated images discriminated by preceding R-R intervals (PRR), and LV filling and function curves were obtained in 62 patients with Af to evaluate LV function. LV filling curve, obtained by plotting end-diastolic volume (EDV) againt PRR, demonstrated that the blood filling was impaired in mitral stenosis and constrictive pericarditis, but recovered after mitral commissurotomy. LV function curve, by plotting stroke volume (SV) againt EDV, was quantitatively analysed by the indices such as Slope and Position. Both indices reduced significantly in heart failure. When compared among underlying diseases individually, the indices decreased in the following order; lone Af, hyperthyroidism, senile Af, hypertension, mitral valve disease, ischemic heart disease, dilated cardiomyopathy and aortic regurgitation. After the treatment with digitalis and/or diuretics, left and upward shift of function curve was observed. The rise in heart rate by atropine infusion made Slope and Position unchanged, and which implied that function curve was little influenced by heart rate per se. The rise in systolic blood pressure by angiotensin-II infusion caused shifts in function curve to rightward and downward. Downward shift, mostly seen in patients with gentler slope in control state, may imply afterload mismatch due to a decrease in preload reserve. (J.P.N.).

  6. Repair of aorto-left ventricular tunnel arising from the left sinus of valsalva.

    Science.gov (United States)

    Nezafati, Mohammad Hassan; Maleki, Mahmood Hosseinzadeh; Javan, Hadi; Zirak, Nahid

    2010-05-01

    Aortico-left ventricular tunnel (ALVT) is a rare congenital cardiac defect that bypasses the aortic valve via a para-valvular connection from the left ventricle to the aorta. In most cases, the tunnel arises from the right aortic sinus. In this case report, we are presenting a case of ALVT, of which the aortic orifice arose from the left aortic sinus, requiring special attention to avoid the left coronary artery injury at the time of surgical repair.

  7. Depressed left and right ventricular cardiac output in fetuses of diabetic mothers

    Directory of Open Access Journals (Sweden)

    Jennifer Winter MD

    2018-01-01

    Full Text Available Introduction: We compared right and left ventricular cardiac output (RVCO and LVCO in fetuses of diabetic mothers (FDM with a large normal cohort. Methods: We prospectively enrolled 264 normal fetuses and 30 FDM. Fetal CO parameters such as semilunar valve velocity time integrals (AVVTI, PVVTI, ventricular outflow diameters (LVOTD, RVOTD and stroke volumes (AVSV, PVSV were measured, and LVCO and RVCO were calculated. These were normalized using non-linear regression to estimated fetal weight (EFW to provide means and standard deviations. Among FDMs, mean Z scores and 95% confidence limits (CL were calculated and compared to zero. Results: LVCO, RVCO and parameters they were calculated from, increased predictably and non-linearly with increasing EFW. In FDM, LVCO was depressed (mean Z −1.679, 95% CL −2.404, −0.955, P < 0.001, and AVVTI, LVOTD and AVSV were significantly lower than normal. Similarly, RVCO (mean Z = −1.119, CL −1.839, −0.400, P = 0.003, RVOTD (mean −2.085, CL −3.077, −1.093, P < 0.001 and PVSV (mean −1.184, CL −1.921, −0.446, P = 0.003 were lower than normal, however, PVVTI was not different (mean Z 0.078, CL −0.552, +0.707, P = 0.803. Conclusion: Normal biventricular stroke volumes and outputs follow a non-linear regression with EFW. FDM have significantly lower right and left heart stroke volumes and outputs for weight than do normal fetuses.

  8. Relationship of central and peripheral blood pressure to left ventricular mass in hypertensive patients.

    Science.gov (United States)

    Pérez-Lahiguera, Francisco J; Rodilla, Enrique; Costa, Jose A; Gonzalez, Carmen; Martín, Joaquin; Pascual, Jose M

    2012-12-01

    The purpose of the present study was to assess the relationship of central and peripheral blood pressure to left ventricular mass. Cross-sectional study that included 392 never treated hypertensive individuals. Measurement of office, 24-h ambulatory, and central blood pressure (obtained using applanation tonometry) and determination of left ventricular mass by echocardiography were performed in all patients. In a multiple regression analysis, with adjustment for age, gender and metabolic syndrome, 24-h blood pressure was more closely related to ventricular mass than the respective office and central blood pressures. Systolic blood pressures always exhibited a higher correlation than diastolic blood pressures in all 3 determinations. The correlation between left ventricular mass index and 24-h systolic blood pressure was higher than that of office (P<.002) or central systolic blood pressures (P<.002). Changes in 24-h systolic blood pressure caused the greatest variations in left ventricular mass index (P<.001). In our population of untreated middle-aged hypertensive patients, left ventricular mass index is more closely related to 24-h ambulatory blood pressure than to office or central blood pressure. Central blood pressure does not enable us to better identify patients with left ventricular hypertrophy. Copyright © 2012 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  9. Image processing of x-ray left ventricular cineangiocardiograms and displays of cardiac functions

    International Nuclear Information System (INIS)

    Eiho, Shigeru; Yamada, Shigeru; Kuwahara, Michiyoshi

    1980-01-01

    Cineangiocardiography has been often used as one of the highly helpful techniques to examine the cardiac function. This paper deals with the method of tracing automatically the boundaries of the left ventricle on cineangiocardiograms, the method to evaluate and display various cardiac functions, the method to reconstruct the left ventricular cavity from biplane cineangiocardiograms and the method to display a 3-dimensional shape of the left ventricle reconstructed. Our algorithm of boundary tracing is based on a heuristic search for a local maximum of the changing rate in the gray level of cineangiocardiogram. The boundaries of endocardial margins of the left ventricle on 80 to 120 consecutive frames are automatically traced by our method. By using the detected boundaries of the left ventricle, a lot of quantitative information may be established on the cardiac function. The volume change, the wall motions and the %-shortening are displayed graphically. The motion of the boundary of the left ventricle is displayed on a CRT as a moving picture. The left ventricular cavity is reconstructed from the detected boundaries of the left ventricle on biplane cineangiocardiograms. A reconstructed image can be shown as superimposed lines or halftone planes to produce a 3-dimensional perspective. The %-shortening which shows the contractility of the regional myocardium is displayed on a silhouette of the left ventricle. We can easily recognize the abnormal area of contraction and the level and spread of abnormality from this displayed image. With the use of the system described in this paper, we can grasp the movement of the left ventricle exactly and evaluate the cardiac function quantitatively. (author)

  10. Pseudonormal and restrictive filling patterns predict left ventricular dilation and cardiac death after a first myocardial infarction

    DEFF Research Database (Denmark)

    Møller, J E; Søndergaard, E; Poulsen, S H

    2000-01-01

    OBJECTIVES: We sought to assess the prognostic value of left ventricular (LV) filling patterns, as determined by mitral E-wave deceleration time (DT) and color M-mode flow propagation velocity (Vp), on cardiac death and serial changes in LV volumes after a first myocardial infarction (MI). BACKGR...

  11. Cardiac arrhythmias and left ventricular hypertrophy in systemic hypertension

    International Nuclear Information System (INIS)

    Sultana, R.; Sultana, N.; Rashid, A.; Rasheed, S.Z.; Ahmed, M.; Ishaq, M.; Samad, A.

    2010-01-01

    Background: Hypertensive left ventricular hypertrophy (LVH) is associated with increased risk of arrhythmias and mortality. Objective was to investigate the prevalence of cardiac arrhythmias and LVH in systemic hypertension. Methods: In all subjects blood pressure was measured, electrocardiography and echocardiography was done. Holter monitoring and exercise test perform in certain cases. There were 500 hypertensive patients, 156 (31.2%) men and 344 (69%) women >30 years of age in the study. Among them 177 (35.4%) were diabetic, 224 (45%) were dyslipidemia, 188 (37.6%) were smokers, and 14 (3%) had homocysteinemia. Mean systolic BP (SBP) was 180 +- 20 mm Hg and diastolic BP (DBP) was 95 +- 12 in male and female patients. Left ventricular mass index (LVMI) was 119.2 +- 30 2 2gm/m in male while 103 +- 22 gm/m in female patients. Palpitation was seen in 126 (25%) male and 299 (59.8%) female patients. Atrial fibrillation was noted in 108 (21.6%) male and 125 (25%) female patients, 30 (6%) male and 82 (16.4%) female patients had atrial flutter. Ventricular tachycardia was noted in 37 (7.4%) male and 59 (11.8%) female patients. Holter monitoring showed significant premature ventricular contractions (PVC'S) in 109 (21.8%) male and 128 (25.69%) female patients while Holter showed atrial arrhythmias (APC'S) in 89 (17.8%) males and 119 (23.8%) females. Angiography findings diagnosed coronary artery disease in 119 (23.8%) with CAD male and 225 (45%) without CAD while 47 (9.4%) females presented with CAD and 109 (21.8%) without CAD. Conclusion: A significant association has been demonstrated between hypertension and arrhythmias. Diastolic dysfunction of the left ventricle, left atrial size and function, as well as LVH have been suggested as the underlying risk factors for supraventricular, ventricular arrhythmias and sudden death in hypertensives with LVH. (author)

  12. Cardiac arrhythmias and left ventricular hypertrophy in systemic hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Sultana, R; Sultana, N; Rashid, A; Rasheed, S Z; Ahmed, M; Ishaq, M; Samad, A [Karachi Institute of Heart Diseases, Karachi (Pakistan)

    2010-10-15

    Background: Hypertensive left ventricular hypertrophy (LVH) is associated with increased risk of arrhythmias and mortality. Objective was to investigate the prevalence of cardiac arrhythmias and LVH in systemic hypertension. Methods: In all subjects blood pressure was measured, electrocardiography and echocardiography was done. Holter monitoring and exercise test perform in certain cases. There were 500 hypertensive patients, 156 (31.2%) men and 344 (69%) women >30 years of age in the study. Among them 177 (35.4%) were diabetic, 224 (45%) were dyslipidemia, 188 (37.6%) were smokers, and 14 (3%) had homocysteinemia. Mean systolic BP (SBP) was 180 +- 20 mm Hg and diastolic BP (DBP) was 95 +- 12 in male and female patients. Left ventricular mass index (LVMI) was 119.2 +- 30 2 2gm/m in male while 103 +- 22 gm/m in female patients. Palpitation was seen in 126 (25%) male and 299 (59.8%) female patients. Atrial fibrillation was noted in 108 (21.6%) male and 125 (25%) female patients, 30 (6%) male and 82 (16.4%) female patients had atrial flutter. Ventricular tachycardia was noted in 37 (7.4%) male and 59 (11.8%) female patients. Holter monitoring showed significant premature ventricular contractions (PVC'S) in 109 (21.8%) male and 128 (25.69%) female patients while Holter showed atrial arrhythmias (APC'S) in 89 (17.8%) males and 119 (23.8%) females. Angiography findings diagnosed coronary artery disease in 119 (23.8%) with CAD male and 225 (45%) without CAD while 47 (9.4%) females presented with CAD and 109 (21.8%) without CAD. Conclusion: A significant association has been demonstrated between hypertension and arrhythmias. Diastolic dysfunction of the left ventricle, left atrial size and function, as well as LVH have been suggested as the underlying risk factors for supraventricular, ventricular arrhythmias and sudden death in hypertensives with LVH. (author)

  13. Normal left ventricular function does not protect against propafenone ...

    African Journals Online (AJOL)

    Normal left ventricular function does not protect against propafenone-induced incessant ventricular tachycardia. R. N. Scott Millar, J. B. Lawrenson, D.A. Milne. Abstract. Propafenone is a class Ic anti-arrhythmic agent with mild B-blocking properties which has recently become available in South Africa. We have used the ...

  14. Left ventricular volume measurements with free breathing respiratory self-gated 3-dimensional golden angle radial whole-heart cine imaging - Feasibility and reproducibility.

    Science.gov (United States)

    Holst, Karen; Ugander, Martin; Sigfridsson, Andreas

    2017-11-01

    To develop and evaluate a free breathing respiratory self-gated isotropic resolution technique for left ventricular (LV) volume measurements. A 3D radial trajectory with double golden-angle ordering was used for free-running data acquisition during free breathing in 9 healthy volunteers. A respiratory self-gating signal was extracted from the center of k-space and used with the electrocardiogram to bin all data into 3 respiratory and 25 cardiac phases. 3D image volumes were reconstructed and the LV endocardial border was segmented. LV volume measurements and reproducibility from 3D free breathing cine were compared to conventional 2D breath-held cine. No difference was found between 3D free breathing cine and 2D breath-held cine with regards to LV ejection fraction, stroke volume, end-systolic volume and end-diastolic volume (Pcine and 2D breath-held cine (Pcine and conventional 2D breath-held cine showed similar values and test-retest repeatability for LV volumes in healthy volunteers. 3D free breathing cine enabled retrospective sorting and arbitrary angulation of isotropic data, and could correctly measure LV volumes during free breathing acquisition. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Screening for Fabry Disease in Left Ventricular Hypertrophy: Documentation of a Novel Mutation

    Energy Technology Data Exchange (ETDEWEB)

    Baptista, Ana, E-mail: baptista-ana@hotmail.com; Magalhães, Pedro; Leão, Sílvia; Carvalho, Sofia; Mateus, Pedro; Moreira, Ilídio [Centro Hospitalar de Trás-os-Montes e Alto Douro, Unidade de Vila Real (Portugal)

    2015-08-15

    Fabry disease is a lysosomal storage disease caused by enzyme α-galactosidase A deficiency as a result of mutations in the GLA gene. Cardiac involvement is characterized by progressive left ventricular hypertrophy. To estimate the prevalence of Fabry disease in a population with left ventricular hypertrophy. The patients were assessed for the presence of left ventricular hypertrophy defined as a left ventricular mass index ≥ 96 g/m{sup 2} for women or ≥ 116 g/m{sup 2} for men. Severe aortic stenosis and arterial hypertension with mild left ventricular hypertrophy were exclusion criteria. All patients included were assessed for enzyme α-galactosidase A activity using dry spot testing. Genetic study was performed whenever the enzyme activity was decreased. A total of 47 patients with a mean left ventricular mass index of 141.1 g/m{sup 2} (± 28.5; 99.2 to 228.5 g/m{sup 2}] were included. Most of the patients were females (51.1%). Nine (19.1%) showed decreased α-galactosidase A activity, but only one positive genetic test − [GLA] c.785G>T; p.W262L (exon 5), a mutation not previously described in the literature. This clinical investigation was able to establish the association between the mutation and the clinical presentation. In a population of patients with left ventricular hypertrophy, we documented a Fabry disease prevalence of 2.1%. This novel case was defined in the sequence of a mutation of unknown meaning in the GLA gene with further pathogenicity study. Thus, this study permitted the definition of a novel causal mutation for Fabry disease - [GLA] c.785G>T; p.W262L (exon 5)

  16. Screening for Fabry Disease in Left Ventricular Hypertrophy: Documentation of a Novel Mutation

    International Nuclear Information System (INIS)

    Baptista, Ana; Magalhães, Pedro; Leão, Sílvia; Carvalho, Sofia; Mateus, Pedro; Moreira, Ilídio

    2015-01-01

    Fabry disease is a lysosomal storage disease caused by enzyme α-galactosidase A deficiency as a result of mutations in the GLA gene. Cardiac involvement is characterized by progressive left ventricular hypertrophy. To estimate the prevalence of Fabry disease in a population with left ventricular hypertrophy. The patients were assessed for the presence of left ventricular hypertrophy defined as a left ventricular mass index ≥ 96 g/m 2 for women or ≥ 116 g/m 2 for men. Severe aortic stenosis and arterial hypertension with mild left ventricular hypertrophy were exclusion criteria. All patients included were assessed for enzyme α-galactosidase A activity using dry spot testing. Genetic study was performed whenever the enzyme activity was decreased. A total of 47 patients with a mean left ventricular mass index of 141.1 g/m 2 (± 28.5; 99.2 to 228.5 g/m 2 ] were included. Most of the patients were females (51.1%). Nine (19.1%) showed decreased α-galactosidase A activity, but only one positive genetic test − [GLA] c.785G>T; p.W262L (exon 5), a mutation not previously described in the literature. This clinical investigation was able to establish the association between the mutation and the clinical presentation. In a population of patients with left ventricular hypertrophy, we documented a Fabry disease prevalence of 2.1%. This novel case was defined in the sequence of a mutation of unknown meaning in the GLA gene with further pathogenicity study. Thus, this study permitted the definition of a novel causal mutation for Fabry disease - [GLA] c.785G>T; p.W262L (exon 5)

  17. Evaluation of left ventricular mass in vitro and in vivo with MR imaging

    International Nuclear Information System (INIS)

    Mogelvang, J.; Thomsen, C.; Mehisen, J.; Henriksen, O.; Horn, T.

    1986-01-01

    The left ventricular (LV) mass was determined by MR multisection imaging in ten unopened postmortem human hearts and compared with the true weight of the isolated LV. In addition, the LV mass in 14 patients was determined by MR imaging. LV myocardial volume determined from acquisitions at end diastole were compared with the volume determined from acquisitions at end systole. The LV masses as determined on MR imaging showed excellent correlation with reference values (r = .99, P < .001). There was fine correlation between myocardial volume (mass) estimated in vivo in diastole and systole (r = .95, P < .0001). These results suggest that MR imaging is accurate for the determination of LV mass in vivo

  18. Silent left ventricular dysfunction during routine activity after thrombolytic therapy for acute myocardial infarction

    International Nuclear Information System (INIS)

    Kayden, D.S.; Wackers, F.J.; Zaret, B.L.

    1990-01-01

    To investigate prospectively the occurrence and significance of postinfarction transient left ventricular dysfunction, 33 ambulatory patients who underwent thrombolytic therapy after myocardial infarction were monitored continuously for 187 +/- 56 min during normal activity with a radionuclide left ventricular function detector at the time of hospital discharge. Twelve patients demonstrated 19 episodes of transient left ventricular dysfunction (greater than 0.05 decrease in ejection fraction, lasting greater than or equal to 1 min), with no change in heart rate. Only two episodes in one patient were associated with chest pain and electrocardiographic changes. The baseline ejection fraction was 0.52 +/- 0.12 in patients with transient left ventricular dysfunction and 0.51 +/- 0.13 in patients without dysfunction (p = NS). At follow-up study (19.2 +/- 5.4 months), cardiac events (unstable angina, myocardial infarction or death) occurred in 8 of 12 patients with but in only 3 of 21 patients without transient left ventricular dysfunction (p less than 0.01). During submaximal supine bicycle exercise, only two patients demonstrated a decrease in ejection fraction greater than or equal to 0.05 at peak exercise; neither had a subsequent cardiac event. These data suggest that transient episodes of silent left ventricular dysfunction at hospital discharge in patients treated with thrombolysis after myocardial infarction are common and associated with a poor outcome. Continuous left ventricular function monitoring during normal activity may provide prognostic information not available from submaximal exercise test results

  19. Impairment of left ventricular function during coronary angioplastic occlusion evaluated with a nonimaging scintillation probe.

    Science.gov (United States)

    Hartmann, A; Maul, F D; Zimny, M; Klepzig, H; Vallbracht, C; Kneissl, H G; Schräder, R; Hör, G; Kaltenbach, M

    1991-09-01

    Impairment of left ventricular function during controlled myocardial ischemia induced by coronary angioplasty has been reported from angiographic and echocardiographic studies. Ejection fraction, peak ejection, peak filling rates, and end-systolic and end-diastolic volumes were investigated before, during and after coronary occlusion on-line with a nonimaging scintillation probe. The study consisted of 18 patients (mean age 59 +/- 10 years) with coronary artery stenosis of greater than 70%. During balloon inflation of 60 seconds' duration, coronary occlusion pressure was 31.6 +/- 12 mm Hg. There was no significant change in heart rate. Delay between first and second dilatation was 109 +/- 63 seconds. Ejection fraction decreased from 53 +/- 16 to 40 +/- 12% (first dilatation, p less than 0.01) and to 39 +/- 14% (second dilatation, p less than 0.01) and recovered to 51 +/- 16% 5 minutes after the second dilatation. Peak ejection rate was significantly reduced during the first and second balloon inflations. Peak filling rate decreased from 2.5 +/- 0.8 to 2.0 +/- 0.7 end-diastolic volume.s-1 (first dilatation, p less than 0.01) and to 1.8 +/- 0.7 end-diastolic volume.s-1 (second dilatation, p less than 0.01) and remained reduced at 2.2 +/- 0.7 end-diastolic volume.s-1 (p = not significant) at 5 minutes after the second dilatation. End-systolic and end-diastolic volumes increased significantly during the first and second dilatations and returned to normal after dilatation. It is concluded that short, controlled myocardial ischemia during coronary angioplasty leads to a decrease in systolic and diastolic left ventricular function. Sequential dilatations do not further decrease function if a sufficient interval is kept.

  20. Left anterior descending coronary artery dissection during ventricular tachycardia ablation – case report

    Directory of Open Access Journals (Sweden)

    Kordic Kresimir

    2018-03-01

    Full Text Available Fascicular left ventricular tachycardia (VT is the second most frequent idiopathic left VT in the setting of a structurally normal heart. Catheter ablation is curative in most patients with low complication rates. We report a case of ostial left anterior descending coronary artery (LAD occlusion during fascicular ventricular tachycardia ablation.

  1. Large right ventricular sinusoids in an infant with aorta-left ventricular tunnel and proximal right coronary artery atresia.

    Science.gov (United States)

    Chen, Peter C; Spinner, Joseph A; Heinle, Jeffrey S

    2018-07-01

    We report a 1-month-old infant diagnosed with an aorta-left ventricular tunnel, ventricular septal defect, and right coronary atresia with right ventricular sinusoids. The patient's anatomy and physiology did not indicate right-ventricular-dependent coronary circulation, and therefore right ventricular decompression could be performed without compromising coronary perfusion during surgical correction. A detailed understanding of the coronary anatomy is critical in managing this defect when coronary anomalies are present.

  2. Left ventricular hypertrophy : virtuous intentions, malign consequences

    NARCIS (Netherlands)

    Pokharel, S; Sharma, UC; Pinto, YM

    Left ventricular hypertrophy (LVH) is currently the focus of intense cardiovascular research, with the resultant rapid evolution of novel concepts relating to its exceedingly complex pathophysiology. In addition to the alterations in signal transduction and disturbances in Ca2+ homeostasis, there

  3. Left ventricular hypertrophy: virtuous intentions, malign consequences

    NARCIS (Netherlands)

    Pokharel, Saraswati; Sharma, Umesh C.; Pinto, Yigal M.

    2003-01-01

    Left ventricular hypertrophy (LVH) is currently the focus of intense cardiovascular research, with the resultant rapid evolution of novel concepts relating to its exceedingly complex pathophysiology. In addition to the alterations in signal transduction and disturbances in Ca(2+) homeostasis, there

  4. Receiver operating characteristics of diagnostic efficacy of resting left ventricular performance (evaluating with a non-imaging ECG gated scintillation detector - nuclear stethoscope)

    International Nuclear Information System (INIS)

    Kotlyarov, E.V.; Reba, R.C.; Lindsay, J.

    1983-01-01

    Receiver operating characteristic (ROC) analysis of left ventricular performance at rest was applied to evaluate diagnostic utility of non-imaging nuclear detector (''Nuclear Stethoscope''), for screening patients with coronary artery disease (CAD). Thirty-one patients without CAD and normal rest and stress radionuclide ventriculography (MUGA) were used as a control group. Another 62 patients with abnormal left ventricular reserve and segmental wall motion abnormalities at rest were also studied. All 93 patients were studied with the Nuclear Stethoscope (30 minutes after conventional MUGA testing) both in beat-to-beat and gated equilibrium modes. ROC analysis showed that along with ejection fraction, stroke and end-diastolic volumes, evaluation of the left ventricular filling phase has a great potential for the identification of patients with a segmental wall motion abnormality and, therefore, significant CAD

  5. Effect of food intake on left ventricular wall stress.

    Science.gov (United States)

    Gårdinger, Ylva; Hlebowicz, Joanna; Björgell, Ola; Dencker, Magnus

    2014-01-28

    Left ventricular wall stress has been investigated in a variety of populations, but the effect of food intake has not been evaluated. We assessed whether left ventricular wall stress is affected by food intake in healthy subjects. Twenty-three healthy subjects aged 25.6 ± 4.5 years were investigated. Meridional end-systolic wall stress (ESS) and circumferential end-systolic wall stress (cESS) were measured before, 30 minutes after, and 110 minutes after a standardised meal. Both ESS and cESS decreased significantly (P stress is affected by food intake in healthy subjects.

  6. Relationship of carotid arterial functional and structural changes to left atrial volume in untreated hypertension.

    Science.gov (United States)

    Jaroch, Joanna; Rzyczkowska, Barbara; Bociąga, Zbigniew; Vriz, Olga; Driussi, Caterina; Loboz-Rudnicka, Maria; Dudek, Krzysztof; Łoboz-Grudzień, Krystyna

    2016-04-01

    The contribution of arterial functional and structural changes to left ventricular (LV) diastolic dysfunction has been the area of recent research. There are some studies on the relationship between arterial stiffness (a.s.) and left atrial (LA) remodelling as a marker of diastolic burden. Little is known about the association of arterial structural changes and LA remodelling in hypertension (H). The aim of this study was to examine the relationship between carotid a.s. and intima-media thickness (IMT) and LA volume in subjects with H. The study included 245 previously untreated hypertensives (166 women and 79 men, mean age 53.7 ± 11.8 years). Each patient was subjected to echocardiography with measurement of LA volume, evaluation of left ventricular hypertrophy (LVH) and LV systolic/diastolic function indices, integrated assessment of carotid IMT and echo-tracking of a.s. and wave reflection parameters. Univariate regression analysis revealed significant correlations between indexed LA volume and selected clinical characteristics, echocardiographic indices of LVH and LV diastolic/systolic function and a.s./wave reflection parameters. The following parameters were identified as independent determinants of indexed LA volume on multivariate regression analysis: diastolic blood pressure (beta = -0.229, P arterial stiffness but not intima-media thickness and LA volume in patients with untreated hypertension.

  7. Equilibrium radionuclide assessment of left ventricular ejection and filling. Comparison of list mode-and multigated frame-mode measurements

    Energy Technology Data Exchange (ETDEWEB)

    Sugrue, D.D.; McKenna, W.J.; Dickie, S.; Oakley, C.M.; Myers, M.J.; Lavender, J.P. (Royal Postgraduate Medical School, London (UK))

    1983-10-01

    The relationship as studied between radionuclide indices of left ventricular systolic and diastolic function acquired in conventional multigated frame-mode compared to list-mode in patients with sinus rhythm. The study showed that frame-mode and list-mode measurements of ejection and filling indices are not significantly different in these patients but that backward reformatting of data acquired in list-mode is necessary to measure the atrial contribution to LV stroke counts. It was concluded that valid measurements of left ventricular systolic ejection and diastolic filling can be made in patients in sinus rhythm using frame-mode acquisition with the exception of measurements of the contribution from atrial systole to stroke volume.

  8. Screening for Fabry Disease in Left Ventricular Hypertrophy: Documentation of a Novel Mutation

    Directory of Open Access Journals (Sweden)

    Ana Baptista

    2015-01-01

    Full Text Available Abstract Background: Fabry disease is a lysosomal storage disease caused by enzyme α-galactosidase A deficiency as a result of mutations in the GLA gene. Cardiac involvement is characterized by progressive left ventricular hypertrophy. Objective: To estimate the prevalence of Fabry disease in a population with left ventricular hypertrophy. Methods: The patients were assessed for the presence of left ventricular hypertrophy defined as a left ventricular mass index ≥ 96 g/m2 for women or ≥ 116 g/m2 for men. Severe aortic stenosis and arterial hypertension with mild left ventricular hypertrophy were exclusion criteria. All patients included were assessed for enzyme α-galactosidase A activity using dry spot testing. Genetic study was performed whenever the enzyme activity was decreased. Results: A total of 47 patients with a mean left ventricular mass index of 141.1 g/m2 (± 28.5; 99.2 to 228.5 g/m2] were included. Most of the patients were females (51.1%. Nine (19.1% showed decreased α-galactosidase A activity, but only one positive genetic test − [GLA] c.785G>T; p.W262L (exon 5, a mutation not previously described in the literature. This clinical investigation was able to establish the association between the mutation and the clinical presentation. Conclusion: In a population of patients with left ventricular hypertrophy, we documented a Fabry disease prevalence of 2.1%. This novel case was defined in the sequence of a mutation of unknown meaning in the GLA gene with further pathogenicity study. Thus, this study permitted the definition of a novel causal mutation for Fabry disease - [GLA] c.785G>T; p.W262L (exon 5.

  9. Is 16-frame really superior to 8-frame gated SPECT for the assessment of left ventricular volumes and ejection fraction? Comparison of two simultaneously acquired gated SPECT studies

    International Nuclear Information System (INIS)

    Montelatici, Giulia; Sciagra, Roberto; Passeri, Alessandro; Dona, Manjola; Pupi, Alberto

    2008-01-01

    Conflicting data exist about the difference between 8- and 16-frame gated single-photon emission computed tomography (SPECT) left ventricular volumes and ejection fraction (EF); moreover, the influence of framing on detection of stress-induced functional changes is unknown. In 133 patients, two separate gated SPECT studies, one with 8 and one with 16 frames, were simultaneously acquired during a single gantry orbit using dedicated software. In 33 of 133 patients, two additional studies (with 8 and 16 frames, respectively) were acquired using arrhythmia rejection. Left ventricular EF and volumes were calculated using the QGS software. Stress-induced ischemia was identified on summed perfusion images. Arrhythmia-rejection did not influence volumes and EF independently of framing rate. Using data without arrhythmia-rejection, there was a significant difference in volumes and EF between 8 and 16 frames both in resting and post-stress gated SPECT. However, the difference was small: 2.6% for resting and 2.8% for post-stress EF. Both using 8 and 16 frames, there were significantly larger volumes and lower EF in patients with than without stress-induced ischemia. A stress-induced decrease >5 EF units was observed in 26 of 133 patients using 8 and in 23 of 133 using 16 frames, respectively, with finding agreement in 19 patients. Comparing two simultaneously acquired studies, the use of 16 instead of 8 frames has minor and predictable influence on functional data. Furthermore, there are no differences in the detection of stress-induced functional changes. The advantage of 16 over 8 frames in the daily clinical practice appears questionable. (orig.)

  10. Recovery of right and left ventricular function after acute pulmonary embolism

    Energy Technology Data Exchange (ETDEWEB)

    Klok, F.A., E-mail: f.a.klok@lumc.nl [Section of Vascular Medicine, Department of General Internal Medicine-Endocrinology, Leiden University Medical Center, Leiden (Netherlands); Romeih, S. [Department of Cardiology, Leiden University Medical Center, Leiden (Netherlands); Kroft, L.J.M.; Westenberg, J.J.M. [Department of Radiology, Leiden University Medical Center, Leiden (Netherlands); Huisman, M.V. [Section of Vascular Medicine, Department of General Internal Medicine-Endocrinology, Leiden University Medical Center, Leiden (Netherlands); Roos, A. de [Department of Radiology, Leiden University Medical Center, Leiden (Netherlands)

    2011-12-15

    Aim: To evaluate recovery of cardiac function after acute pulmonary embolism (PE). Materials and methods: Routine breath-held computed tomography (CT)-pulmonary angiography was performed in patients with suspected PE to confirm or exclude the diagnosis of PE at initial presentation. Electrocardiogram (ECG)-triggered cardiac CT was performed to assess biventricular function. After 6 months, cardiac magnetic resonance imaging (MRI) was performed. In total, 15 consecutive patients with PE and 10 without were studied. A significant change in ventricular volume was defined as a >15% change in end-diastolic or -systolic volumes (EDV, ESV), and significant ventricular function improvement as a >5% increase in ejection fraction (EF) as based on reported cut-off values. Results: Right and left ventricular (RV and LV) EDV and ESV changed non-significantly (<1.3%) in the patients without PE, indicating good comparability of those values measured by CT and MRI. PE patients with baseline normal RV function (RVEF {>=}47%) revealed a >5% improvement in the RVEF (+5.4 {+-} 3.1%) due to a decrease in the RVESV. Patients with baseline abnormal RV function showed a >5% improvement in the RVEF (+14 {+-} 15%) due to decreases in both the RVESV and RVEDV. Furthermore, the LVEDV increased in this latter patient group. Conclusions: The present study demonstrated an improvement in RV function in the majority of patients with PE, independent of baseline RV function. The degree of RV and LV recovery was dependent on the severity of baseline RV dysfunction.

  11. Gender specific pattern of left ventricular cardiac adaptation to ...

    African Journals Online (AJOL)

    Background: Cardiac adaptation to hypertension and obesity may be related to many factors such as race, gender and haemodynamic status. Some gender specific associations with left ventricular structure and function have been described among Caucasians. Objectives: To describe the sex specific pattern of left ...

  12. Quantification of Global Left Ventricular Function: Comparison of Multidetector Computed Tomography and Magnetic Resonance Imaging. A Meta-analysis and Review of the Current Literature

    International Nuclear Information System (INIS)

    Vleuten, P.A. van der; Willems, T.P.; Goette, M.J.; Tio, R.A.; Greuter, M.J.; Zijlstra, F.; Oudkerk, M.

    2006-01-01

    Cardiac morbidity and mortality are closely related to cardiac volumes and global left ventricular (LV) function, expressed as left ventricular ejection fraction. Accurate assessment of these parameters is required for the prediction of prognosis in individual patients as well as in entire cohorts. The current standard of reference for left ventricular function is analysis by short-axis magnetic resonance imaging. In recent years, major extensive technological improvements have been achieved in computed tomography. The most marked development has been the introduction of the multidetector CT (MDCT), which has significantly improved temporal and spatial resolutions. In order to assess the current status of MDCT for analysis of LV function, the current available literature on this subject was reviewed. The data presented in this review indicate that the global left ventricular functional parameters measured by contemporary multi-detector row systems combined with adequate reconstruction algorithms and post-processing tools show a narrow diagnostic window and are interchangeable with those obtained by MRI

  13. Ethical considerations of transparency, informed consent, and nudging in a patient with paediatric aortic stenosis and symptomatic left ventricular endocardial fibroelastosis.

    Science.gov (United States)

    Mavroudis, Constantine D; Cook, Thomas; Jacobs, Jeffrey P; Mavroudis, Constantine

    2016-12-01

    A 9-year-old boy who was born with bicuspid aortic stenosis underwent two unsuccessful aortic valvuloplasty interventions, and by 2 years of age he developed restrictive cardiomyopathy caused by left ventricular endocardial fibroelastosis and diastolic dysfunction. The attending cardiologist referred the patient to a high-volume, high-profile congenital cardiac surgical programme 1000 miles away that has a team with considerable experience with left ventricular endocardial fibroelastosis resection and a reputation of achieving good results. Owing to problems with insurance coverage, the parents sought other options for the care of their child in their home state. Dr George Miller is a well-respected local congenital and paediatric cardiac surgeon with considerable experience with the Ross operation as well as with right ventricular endocardial fibroelastosis resection. When talking with Dr Miller, he implied that there is little difference between right ventricular endocardial fibroelastosis and left ventricular endocardial fibroelastosis resection, and stated that he would perform the operation with low mortality based on his overall experience. Dr Miller stated that the local institution could provide an equivalent surgical procedure with comparable outcomes, without the patient and family having to travel out of state. A fundamental dilemma that often arises in clinical surgical practice concerns the conduct of assessing and performing new procedures, especially in rare cases, for which the collective global experience is scant. Although Dr Miller has performed right ventricular endocardial fibroelastosis resection, this procedure differs from left ventricular endocardial fibroelastosis resection, and he cannot be sure that he will indeed be able to perform the procedure better than the high-volume surgeon. This ethical situation is best understood in terms of the principles of respect for patient autonomy, beneficence, non-maleficence, and justice. The tension

  14. Impact of hypertension on left ventricular structure in patients with asymptomatic aortic valve stenosis (a SEAS substudy)

    DEFF Research Database (Denmark)

    Rieck, Ashild E; Cramariuc, Dana; Staal, Eva M

    2010-01-01

    Both hypertension and aortic valve stenosis induce left ventricular hypertrophy. However, less is known about the influence of concomitant hypertension on left ventricular structure in patients with aortic valve stenosis.......Both hypertension and aortic valve stenosis induce left ventricular hypertrophy. However, less is known about the influence of concomitant hypertension on left ventricular structure in patients with aortic valve stenosis....

  15. Left ventricular dysfunction and blood glycohemoglobin levels in young diabetics

    Energy Technology Data Exchange (ETDEWEB)

    Aydiner, A.; Oto, A.; Oram, E.; Oram, A.; Ugurlu, S.; Karamehmetoglu, A. (Hacettepe Univ., Ankara (Turkey). Dept. of Cardiology); Aras, T.; Bekdik, C.F. (Hacettepe Univ., Ankara (Turkey). Dept. of Nuclear Medicine); Gedik, O. (Hacettepe Univ., Ankara (Turkey). Dept. of Endocrinology)

    1991-10-01

    Left ventricular function including regional wall motion (RWM) was evaluated by {sup 99m}Tc first-pass and equilibrium gated blood pool ventriculography and glycohemoglobin (HbA1c) blood levels determined by a quantitative column technique in 25 young patients with insulin-dependent diabetes mellitus without clinical evidence of heart diesease, and in healthy controls matched for age and sex. Phase analysis revealed abnormal RWM in 19 of 21 diabetic patients. The mean left ventricular global ejection fraction, the mean regional ejection fraction and the mean 1/3 filling fraction were lower and the time to peak ejection, the time to peak filling and the time to peak ejection/cardiac cycle were longer in diabetics than in controls. We found high HbA1c levels in all diabetics. There was no significant difference between patients with and without retinopathy and with and without peripheral neuropathy in terms of left ventricular function and HbA1c levels. (orig.).

  16. Left ventricular dysfunction and blood glycohemoglobin levels in young diabetics

    International Nuclear Information System (INIS)

    Aydiner, A.; Oto, A.; Oram, E.; Oram, A.; Ugurlu, S.; Karamehmetoglu, A.; Aras, T.; Bekdik, C.F.; Gedik, O.

    1991-01-01

    Left ventricular function including regional wall motion (RWM) was evaluated by 99m Tc first-pass and equilibrium gated blood pool ventriculography and glycohemoglobin (HbA1c) blood levels determined by a quantitative column technique in 25 young patients with insulin-dependent diabetes mellitus without clinical evidence of heart diesease, and in healthy controls matched for age and sex. Phase analysis revealed abnormal RWM in 19 of 21 diabetic patients. The mean left ventricular global ejection fraction, the mean regional ejection fraction and the mean 1/3 filling fraction were lower and the time to peak ejection, the time to peak filling and the time to peak ejection/cardiac cycle were longer in diabetics than in controls. We found high HbA1c levels in all diabetics. There was no significant difference between patients with and without retinopathy and with and without peripheral neuropathy in terms of left ventricular function and HbA1c levels. (orig.) [de

  17. Estimation of left ventricular operating stiffness from Doppler early filling deceleration time in humans.

    Science.gov (United States)

    Garcia, M J; Firstenberg, M S; Greenberg, N L; Smedira, N; Rodriguez, L; Prior, D; Thomas, J D

    2001-02-01

    Shortened early transmitral deceleration times (E(DT)) have been qualitatively associated with increased filling pressure and reduced survival in patients with cardiac disease and increased left ventricular operating stiffness (K(LV)). An equation relating K(LV) quantitatively to E(DT) has previously been described in a canine model but not in humans. During several varying hemodynamic conditions, we studied 18 patients undergoing open-heart surgery. Transesophageal echocardiographic two-dimensional volumes and Doppler flows were combined with high-fidelity left atrial (LA) and left ventricular (LV) pressures to determine K(LV). From digitized Doppler recordings, E(DT) was measured and compared against changes in LV and LA diastolic volumes and pressures. E(DT) (180 +/- 39 ms) was inversely associated with LV end-diastolic pressures (r = -0.56, P = 0.004) and net atrioventricular stiffness (r = -0.55, P = 0.006) but had its strongest association with K(LV) (r = -0.81, P < 0.001). K(LV) was predicted assuming a nonrestrictive orifice (K(nonrest)) from E(DT) as K(nonrest) = (0.07/E(DT))(2) with K(LV) = 1.01 K(nonrest) - 0.02; r = 0.86, P < 0.001, DeltaK (K(nonrest) - K(LV)) = 0.02 +/- 0.06 mm Hg/ml. In adults with cardiac disease, E(DT) provides an accurate estimate of LV operating stiffness and supports its application as a practical noninvasive index in the evaluation of diastolic function.

  18. Right and left ventricular ejection fraction at rest and during exercise assessed with radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Dahlstroem, J.A.

    1982-01-01

    Right (RVEF) and left ventricular ejection fraction (LVEF) assessed with radionuclide angiocardiography were compared to simultaneously obtained catheterization results at rest and during exercise in patients with pulmonary hypertension and ischemic heart disease. Blood pool imaging was performed with red blood cells (RBC) labelled with 99 Tcsup(m) in vivo as this method gave more stable 99 Tcsup(m) levels in blood compared to 99 Tcsup(m)-labelled human serum albumin and because it was more convenient than labelling RBC in vitro. RVEF measured with first pass (FP) technique and equilibrium (EQ) technique correlated well at rest, r = 0.86, and during exercise, r = 0.91. The FP technique had the best reproducibility and reference values at rest were 49+-5 per cent increasing with exercise. When 99 Tcsup(m) and 133 Xe were compared to assess RVEF with FP technique, the correlation was good, r = 0.88. LVEF assessed with EQ technique and a fixed end-diastolic region of interest was very reproducible at rest and during exercise; reference values at rest were 56+-8 per cent increasing with exercise. In 10 patients with pulmonary hypertension significant negative correlations were found between RVEF assessed with FP technique and pressures in pulmonary artery and right atrium. Abnormal RVEF was found in all patients with right ventricular disfunction. In 22 patients with recent myocardial infarction measurements of LVEF detected left ventricular disfunction better than did measurement of pulmonary artery diastolic pressure. During effort angina in another 10 patients all had abnormal LVEF and abnormal hemodynamics. By combining ejection fraction and stroke volume, ventricular volumes were calculated at rest and during exercise. (author)

  19. Evolutionary changes in left and right ventricular function in acute myocardial infarction

    International Nuclear Information System (INIS)

    Ohsuzu, Fumitaka; Yasuda, Tsunehiro; Gold, H.K.; Leinbach, R.C.; Rosenthal, S.V.; Alpert, N.M.; Boucher, C.A.; McKusick, K.A.; Strauss, H.W.

    1987-01-01

    To determine the evolutionary changes in right and left ventricular function in acute myocardial infarction, 3 serial gated blood pool scans were performed in 76 patients within 24 hours (24 H), at 10 days (10 D) and 3 months (3 M) following the onset of myocardial infarction. The patients were divided into 3 groups: ANT (anterior MI), INF (inferior MI without right ventricular dysfunction) and RVF (inferior MI with right ventricular dysfunction). LVEF in ANT was significantly lower than that of INF and RVF at 24 H, 10 D and 3 M. The ratio of right ventricular volume to LV volume (RVV/LVV) was compared among 3 groups. The mean values of RVV/LVV in RVF were 1.3 through 24 H and 3 M and they were significantly higher than the other two groups. The RVV/LVV in ANT and INF were around 1.0. LVEDVI in RVF was rather smaller than that of ANT and INF. LVESVI in ANT at 24 H was significantly larger than that of INF and RVF and the mean value of LVESVI in ANT were around 60 ml/M 2 from 24 H to 3 M. LVEF in ANT, RVF and INF did not increase significantly during peak exercise at 3 M. However, quantitative regional wall motion analysis revealed that regional wall motion of R2 (posterolateral wall motion) in ANT and R5 (septal wall motion) in INF decreased significantly during peak exercise. These impairments in regional wall motion might be due to the exacerbation of ischemia of non-infarcted area. (author)

  20. Evolutionary changes in left and right ventricular function in acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Ohsuzu, Fumitaka; Yasuda, Tsunehiro; Gold, H K; Leinbach, R C; Rosenthal, S V; Alpert, N M; Boucher, C A; McKusick, K A; Strauss, H W

    1987-09-01

    To determine the evolutionary changes in right and left ventricular function in acute myocardial infarction, 3 serial gated blood pool scans were performed in 76 patients within 24 hours (24 H), at 10 days (10 D) and 3 months (3 M) following the onset of myocardial infarction. The patients were divided into 3 groups: ANT (anterior MI), INF (inferior MI without right ventricular dysfunction) and RVF (inferior MI with right ventricular dysfunction). LVEF in ANT was significantly lower than that of INF and RVF at 24 H, 10 D and 3 M. The ratio of right ventricular volume to LV volume (RVVLVV) was compared among 3 groups. The mean values of RVVLVV in RVF were 1.3 through 24 H and 3 M and they were significantly higher than the other two groups. The RVVLVV in ANT and INF were around 1.0. LVEDVI in RVF was rather smaller than that of ANT and INF. LVESVI in ANT at 24 H was significantly larger than that of INF and RVF and the mean value of LVESVI in ANT were around 60 mlM/sup 2/ from 24 H to 3 M. LVEF in ANT, RVF and INF did not increase significantly during peak exercise at 3 M. However, quantitative regional wall motion analysis revealed that regional wall motion of R2 (posterolateral wall motion) in ANT and R5 (septal wall motion) in INF decreased significantly during peak exercise. These impairments in regional wall motion might be due to the exacerbation of ischemia of non-infarcted area

  1. Changes with age in left ventricular function and volumes at rest and postexercise in postmenopausal women

    International Nuclear Information System (INIS)

    Yamada, Kiyoyasu; Isobe, Satoshi; Hirai, Makoto

    2006-01-01

    In postmenopausal women, it has been reported that the plasma estrogen levels diminish immediately after menopause, and that this phenomenon affects left ventricular (LV) function and volumes. However, the effects of age on LV function and volumes for a relatively short period in the postmenopausal women remain to be established. Electrocardiographically gated-myocardial single-photon emission computed tomography (SPECT) has recently provided accurate estimations of perfusion, cardiac systolic and diastolic functions. We investigated the age-related changes in LV function and volumes in postmenopausal women using electrocardiographically gated-myocardial scintigraphy. Twenty-two consecutive healthy postmenopausal women (mean age of 63.8±9.4 years, from 42 to 77 years) without cardiac disease underwent stress/rest technetium-99m tetrofosmin gated-myocardial SPECT with 16 frames per cardiac cycle at baseline and follow-up (1.0±0.3 years later). LV ejection fraction (LVEF) and LV volumes were calculated by quantitative gated SPECT (QGS) software. Fourier series were retained for the analysis of the volume curve. From this volume curve, we derived the following diastolic indices: peak filling rate (PFR) and time to PFR (TPFR). End-systolic volume index (ESVI) significantly decreased at postexercise (p=0.02) and tended to decrease at rest (p=0.06) from the baseline to the follow-up study. LVEF significantly increased at both postexercise (p=0.01) and rest (p=0.03) from the baseline to the follow-up study. The TPFR at rest tended to be prolonged from the baseline to the follow-up study (p=0.07). The absolute increase in LVEF at postexercise tended to decrease with age [4.8% (50s) vs. 3.4% (60s) vs. 1.2% (70s)]. An age-related change in cardiac performance is apparent at an approximately 1 year follow-up in postmenopausal women. In particular, the increase in LV systolic function tends to show the greatest value in the 50s subjects among the 3 generations. (author)

  2. Metabolic volume performs better than SUVmax in the detection of left ventricular assist device driveline infection

    Energy Technology Data Exchange (ETDEWEB)

    Avramovic, Nemanja; Weckesser, Matthias; Milankovic, Danka; Vrachimis, Alexis; Wenning, Christian [University Hospital Muenster, Department of Nuclear Medicine, Muenster (Germany); Dell' Aquila, Angelo Maria; Sindermann, Juergen R. [University Hospital Muenster, Department of Cardiac Surgery, Muenster (Germany)

    2017-10-15

    A continuous-flow left ventricular assist device (LVAD) is a new and highly promising therapy in supporting end-stage heart failure patients, either bridging them to heart transplantation or as a destination therapy. Infection is one of the major complications associated with LVAD implants. {sup 18}F-FDG PET/CT has already been shown to be useful in the detection of LVAD infection. The goal of this study was to compare the diagnostic accuracy of different PET analysis techniques (visual grading versus SUVmax and metabolic volume). We retrospectively analyzed 48 patients with implanted LVAD who underwent an {sup 18}F-FDG PET/CT that were either suspected to have a driveline or device infection or inflammation of unknown origin. PET/CT was analyzed qualitatively (visual grading) and quantitatively (SUVmax and metabolic volume) and matched to the final clinical diagnosis concerning driveline infection. The final diagnosis (standard of reference) was made at the end of clinically recorded follow-up or transplantation and included microbiological cultures of the driveline exit site and/or surgical samples, and clinical signs of infection despite negative cultures as well as recurrence of symptoms. Sensitivity, specificity, positive and negative predictive value were 87.5%, 79%, 81% and 86% for visual score, 87.5%, 87.5%, 87.5% and 87.5% for SUVmax and 96%, 87.5%, 88.5%, 95.5% for metabolic volume, respectively. ROC analysis revealed an AUC of.929 for SUVmax and.969 for metabolic volume. Both SUVmax and metabolic volume had a high detection rate of patients with driveline infection (21/24 = 91.5% true positive vs. 23/26 = 88.5% true positive, respectively). However, metabolic volume detected more patients without any infection correctly (1/22 = 4.5% false negative vs. 3/24 = 12.5% false negative). {sup 18}F-FDG PET/CT is a valuable tool for the diagnosis of LVAD driveline infection with high diagnostic accuracy. Particularly the use of the metabolic volume yields very

  3. NT-pro-BNP levels in patients with acute pulmonary embolism are correlated to right but not left ventricular volume and function.

    Science.gov (United States)

    Pasha, Sharif M; Klok, Frederikus A; van der Bijl, Noortje; de Roos, Albert; Kroft, Lucia J M; Huisman, Menno V

    2012-08-01

    N-terminal pro-Brain Natriuretic Peptide (NT-pro-BNP) is primarily secreted by left ventricular (LV) stretch and wall tension. Notably, NT-pro-BNP is a prognostic marker in acute pulmonary embolism (PE), which primarily stresses the right ventricle (RV). We sought to evaluate the relative contribution of the RV to NT-pro-BNP levels during PE. A post-hoc analysis of an observational prospective outcome study in 113 consecutive patients with computed tomography (CT)-proven PE and 226 patients in whom PE was clinically suspected but ruled out by CT. In all patients RV and LV function was established by assessing ECG-triggered-CT measured ventricular end-diastolic-volumes and ejection fraction (EF). NT-pro-BNP was assessed in all patients. The correlation between RV and LV end-diastolic-volumes and systolic function was evaluated by multiple linear regression corrected for known confounders. In the PE cohort increased RVEF (β-coefficient (95% confidence interval [CI]) -0.044 (± -0.011); p<0.001) and higher RV end-diastolic-volume (β-coefficient 0.005 (± 0.001); p<0.001) were significantly correlated to NT-pro-BNP, while no correlation was found with LVEF (β-coefficient 0.005 (± 0.010); p=0.587) and LV end-diastolic-volume (β-coefficient -0.003 (± 0.002); p=0.074). In control patients without PE we found a strong correlation between NT-pro-BNP levels and LVEF (β-coefficient -0.027 (± -0.006); p<0.001) although not LV end-diastolic-volume (β-coefficient 0.001 (± 0.001); p=0.418). RVEF (β-coefficient -0.002 (± -0.006); p=0.802) and RV end-diastolic-volume (β-coefficient <0.001 (± 0.001); p=0.730) were not correlated in patients without PE. In PE patients, lower RVEF and higher RV end-diastolic-volume were significantly correlated to NT-pro-BNP levels as compared to control patients without PE. These observations provide pathophysiological ground for the well-known prognostic value of NT-pro-BNP in acute PE.

  4. Routine measurements of left and right ventricular output by gated blood pool emission tomography in comparison with thermodilution measurements: a preliminary study

    International Nuclear Information System (INIS)

    Mariano-Goulart, D.; Boudousq, V.; Comte, F.; Eberle, M.C.; Zanca, M.; Kotzki, P.O.; Rossi, M.; Piot, C.; Raczka, F.; Davy, J.M.

    2001-01-01

    The aim of this preliminary study was to evaluate the accuracy of left and right ventricular output computed from a semi-automatic processing of tomographic radionuclide ventriculography data (TRVG) in comparison with the conventional thermodilution method. Twenty patients with various heart diseases were prospectively included in the study. Thermodilution and TRVG acquisitions were carried out on the same day for all patients. Analysis of gated blood pool slices was performed using a watershed-based segmentation algorithm. Right and left ventricular output measured by TRVG correlated well with the measurements obtained with thermodilution (r=0.94 and 0.91 with SEE=0.38 and 0.46 l/min, respectively, P<0.001). The limits of agreement for TRVG and thermodilution measurements were -0.78-1.20 l/min for the left ventricle and -0.34-1.16 l/min for the right ventricle. No significant difference was found between the results of TRVG and thermodilution with respect to left ventricular output (P=0.09). A small but significant difference was found between right ventricular output measured by TRVG and both left ventricular output measured by TRVG (mean difference=0.17 l/min, P=0.04) and thermodilution-derived cardiac output (mean difference=0.41 l/min, P=0.0001). It is concluded that the watershed-based semi-automatic segmentation of TRVG slices provides non-invasive measurements of right and left ventricular output and stroke volumes at equilibrium, in routine clinical settings. Further studies are necessary to check whether the accuracy of these measurements is good enough to permit correct assessment of intracardiac shunts. (orig.)

  5. Second statement of the working group on electrocardiographic diagnosis of left ventricular hypertrophy

    DEFF Research Database (Denmark)

    Bacharova, Ljuba; Estes, E Harvey; Bang, Lia E

    2011-01-01

    The Working Group on Electrocardiographic Diagnosis of Left Ventricular Hypertrophy, appointed by the Editor of the Journal of Electrocardiology, presents the alternative conceptual model for the ECG diagnosis of left ventricular hypertrophy (LVH). It is stressed that ECG is a record of electrica...

  6. Comparison of exercise capacity with resting left ventricular function evaluated by various non-invasive methods in patients with old myocardial infarction

    International Nuclear Information System (INIS)

    Yamabe, Hiroshi; Kobayashi, Katsuya; Tajiri, Eiichi; Hayakawa, Masanori; Minamiji, Katsumi

    1982-01-01

    The relationship between exercise capacity and resting left ventricular function assessed by several non-invasive methods in patients with old myocardial infarction was investigated. Subjects were 25 male patients whose endpoint was either dyspnea or general fatigue at the symptom-limited maximal graded treadmill exercise test according to Bruce protocol. The indices obtained by non-invasive cardiac examinations included left ventricular fractional shortening (% FS), scintigraphic infact size (% SIS) by 201 Tl myocardial scintigraphy and PEP/ET. A significant correlation of exercise duration with % FS (r = 0.67, p < 0.001) or with % SIS (r = -0.55, p < 0.02) indicated that the more impaired resting left ventricular function, the more was decreased exercise capacity. Also, a significant correlation of systolic blood pressure at the endpoint in exercise test with % FS (r = 0.58, p < 0.005) or with % SIS (r = 0.69, p < 0.001) indicated that inadequate blood pressure response might be partially attributed to impaired left ventricular function during exercise. The response of heart rate at the Bruce protocol stage I correlated with % FS (r = -0.67, p < 0.001) and with % SIS (r = 0.53, p < 0.02), respectively. These findings may be interpreted as chronotropic compensatory mechanism for limited stroke volume during exercise in patients with impaired left ventricular function. Thus, it was concluded that resting left ventricular function assessed by non-invasive cardiac examinations may predict exercise capacity prior to the test to some extent. These informations can be utilized for the decision of the planning at cardiac rehabilitation and also for the guidance in daily activities. (J.P.N.)

  7. Assessment of left ventricular wall motion and function by cross-sectional echocardiography

    International Nuclear Information System (INIS)

    Ono, Akifumi; Hirata, Shunkichi; Ishikawa, Kyozo

    1982-01-01

    The clinical efficacy of cross-sectional echocardiography (CSE) was evaluated with M-mode echocardiography and radionuclide cardioangiography (RCG) in 50 cases including 30 patients with myocardial infarction. Segmental wall motion by CSE was highly correlated with segmental wall motion and left ventricular ejection fraction by RCG (r = 0.89 in the former, r = -0.84 in the latter). On the other hand, the left ventricular ejection fraction by M-mode echocardiography revealed a fairly well correlation with that by RCG ( r = 0.68). These results suggest that, as compared with RCG, CSE is quite useful in an evaluation of left ventricular function and in a detection of segmental wall motion abnormalities. (author)

  8. Ventricular distension and diastolic coronary blood flow in the anaesthetized dog.

    Science.gov (United States)

    Gattullo, D; Linden, R J; Losano, G; Pagliaro, P; Westerhof, N

    1993-01-01

    There appears to be no agreement as to whether or not an increase in diastolic left ventricular pressure and/or volume can cause a decrease in diastolic coronary blood flow. We investigated the problem in the anaesthetized dog using a flaccid freely distensible latex balloon inserted into the left ventricle with the animal on extracorporeal circulation and the coronary perfusion pressure constant at about 45 mm Hg. Maximal vasodilatation and suppression of autoregulation in coronary vasculature was obtained by the intracoronary infusion of dipyridamole (10-40 mg/h). Ventricular volume was changed in steps of 10 ml from 10 to 70 ml and back to 10 ml, whilst recording coronary blood flow and left ventricular pressure in the left circumflex coronary artery. Over a range of ventricular volumes from 20 to 50 ml and a concomitant rise in diastolic ventricular pressure to about 20 mm Hg there was no change in the diastolic coronary flow. Only when the ventricular volume was more than two times the control value (i.e. exceeded 50 ml) and left ventricular pressure was more than 20 mm Hg, was there a decrease in coronary flow. During the return of the volume to the control level there was a fall in diastolic flow and ventricular contractility with respect to the values obtained when the volume was increased; these two effects were transient lasting less than 10 min. It was not considered that any of the three models of the coronary circulation, waterfall, intramyocardial pump or varying elastance model could explain our results.(ABSTRACT TRUNCATED AT 250 WORDS)

  9. Development of automatic extraction method of left ventricular contours on long axis view MR cine images

    International Nuclear Information System (INIS)

    Utsunomiya, Shinichi; Iijima, Naoto; Yamasaki, Kazunari; Fujita, Akinori

    1995-01-01

    In the MRI cardiac function analysis, left ventricular volume curves and diagnosis parameters are obtained by extracting the left ventricular cavities as regions of interest (ROI) from long axis view MR cine images. The ROI extractions had to be done by manual operations, because automatization of the extraction is difficult. A long axis view left ventricular contour consists of a cardiac wall part and an aortic valve part. The above mentioned difficulty is due to the decline of contrast on the cardiac wall part, and the disappearance of edge on the aortic valve part. In this paper, we report a new automatic extraction method for long axis view MR cine images, which needs only 3 manually indicated points on the 1st image to extract all the contours from the total sequence of images. At first, candidate points of a contour are detected by edge detection. Then, selecting the best matched combination of candidate points by Dynamic Programming, the cardiac wall part is automatically extracted. The aortic valve part is manually extracted for the 1st image by indicating both the end points, and is automatically extracted for the rest of the images, by utilizing the aortic valve motion characteristics throughout a cardiac cycle. (author)

  10. Impact of endothelial dysfunction on left ventricular remodeling after successful primary coronary angioplasty for acute myocardial infarction. Analysis by quantitative ECG-gated SPECT

    International Nuclear Information System (INIS)

    Matsuo, Shinro; Nakae, Ichiro; Matsumoto, Tetsuya; Horie, Minoru

    2006-01-01

    We hypothesized that endothelial cell integrity in the risk area would influence left ventricular remodeling after acute myocardial infarction. Twenty patients (61±8 y.o.) with acute myocardial infarction underwent 99m Tc-tetrofosmin imaging in the sub-acute phase and three months after successful primary angioplasty due to myocardial infarction. All patients were administered angiotensin-converting enzyme inhibitor after revascularization. Cardiac scintigraphies with quantitative gated SPECT were performed at the sub-acute stage and again 3 months after revascularization to evaluate left ventricular (LV) remodeling. The left ventricular ejection fraction (EF) and end-systolic and end-diastolic volume (ESV, EDV) were determined using a quantitative gated SPECT (QGS) program. Three months after myocardial infarction, all patients underwent cardiac catheterization examination with coronary endothelial function testing. Bradykinin (BK) (0.2, 0.6, 2.0 μg/min) was administered via the left coronary artery in a stepwise manner. Coronary blood flow was evaluated by Doppler flow velocity measurement. Patients were divided into two groups by BK-response: a preserved endothelial function group (n=10) and endothelial dysfunction group (n=10). At baseline, both global function and LV systolic and diastolic volumes were similar in both groups. However, LV ejection fraction was significantly improved in the preserved-endothelial function group, compared with that in the endothelial dysfunction group (42±10% to 48±9%, versus 41±4% to 42±13%, p<0.05). LV volumes progressively increased in the endothelial dysfunction group compared to the preserved-endothelial function group (123±45 ml to 128±43 ml, versus 111±47 ml to 109±49 ml, p<0.05). In re-perfused acute myocardial infarction, endothelial function within the risk area plays an important role with left ventricular remodeling after myocardial infarction. (author)

  11. Right ventricular longitudinal strain and right ventricular stroke work index in patients with severe heart failure: left ventricular assist device suitability for transplant candidates.

    Science.gov (United States)

    Cameli, M; Bernazzali, S; Lisi, M; Tsioulpas, C; Croccia, M G; Lisi, G; Maccherini, M; Mondillo, S

    2012-09-01

    Right ventricular (RV) systolic function has a critical role in determining the clinical outcome and the success of using left ventricular assist devices in patients with refractory heart failure. RV deformation analysis by speckle tracking echocardiography (STE) has recently allowed the analysis of RV longitudinal function. Using cardiac catheterization as the reference standard, this study aimed to explore the correlation between RV longitudinal function by STE and RV stroke work index (RVSWI) among patients referred for cardiac transplantation. Right heart catheterization and transthoracic echo-Doppler were simultaneously performed in 47 patients referred for cardiac transplant assessment due to refractory heart failure (ejection fraction 25.1 ± 4.5%). Thermodilution RV stroke volume and invasive pulmonary pressures were used to obtain RVSWI. RV longitudinal strain (RVLS) by STE was assessed averaging RV free-wall segments (free-wall RVLS). We also calculated. Tricuspid S' and tricuspid annular plane systolic excursion (TAPSE). No significant correlation was observed for TAPSE on tricuspid S' with RV stroke volume (r = 0.14 and r = 0.06, respectively). A close negative correlation between free-wall RVLS and RVSWI was found (r = -0.82; P rights reserved.

  12. Late deterioration of left ventricular function after right ventricular pacemaker implantation.

    Science.gov (United States)

    Bellmann, Barbara; Muntean, Bogdan G; Lin, Tina; Gemein, Christopher; Schmitz, Kathrin; Schauerte, Patrick

    2016-09-01

    Right ventricular (RV) pacing induces a left bundle branch block pattern on ECG and may promote heart failure. Patients with dual chamber pacemakers (DCPs) who present with progressive reduction in left ventricular ejection fraction (LVEF) secondary to RV pacing are candidates for cardiac resynchronization therapy (CRT). This study analyzes whether upgrading DCP to CRT with the additional implantation of a left ventricular (LV) lead improves LV function in patients with reduced LVEF following DCP implantation. Twenty-two patients (13 males) implanted with DCPs and a high RV pacing percentage (>90%) were evaluated in term of new-onset heart failure symptoms. The patients were enrolled in this retrospective single-center study after obvious causes for a reduced LVEF were excluded with echocardiography and coronary angiography. In all patients, DCPs were then upgraded to biventricular devices. LVEF was analyzed with a two-sided t-test. QRS duration and brain natriuretic peptide (BNP) levels were analyzed with the unpaired t-test. LVEF declined after DCP implantation from 54±10% to 31±7%, and the mean QRS duration was 161±20 ms during RV pacing. NT-pro BNP levels were elevated (3365±11436 pmol/L). After upgrading to a biventricular device, a biventricular pacing percentage of 98.1±2% was achieved. QRS duration decreased to 108±16 ms and 106±20 ms after 1 and 6 months, respectively. There was a significant increase in LVEF to 38±8% and 41±11% and a decrease in NT-pro BNP levels to 3088±2326 pmol/L and 1860±1838 pmol/L at 1 and 6 months, respectively. Upgrading to CRT may be beneficial in patients with DCPs and heart failure induced by a high RV pacing percentage.

  13. Gene Polymorphism and Left Ventricular Geometry and Function in Hypertensive Subjects

    Directory of Open Access Journals (Sweden)

    Rosario Scaglione

    2010-01-01

    Full Text Available The distribution of the T29C TGFβ1 gene polymorphism was analyzed in 198 hypertensives with left ventricular hypertrophy (LVH and in 235 hypertensives without LVH. Circulating TGFβ1 levels, procollagen type III levels, microalbuminuria, and left ventricular geometry and function were evaluated in all the hypertensives with LVH subgrouped according to T29C TGFβ1 gene polymorphism. Circulating TGFβ1 was evaluated by ELISA technique, procollagen type III by a specific radioimmunoassay, microalbuminuria by radioimmunoassay, and left ventricular geometry and function by echocardiography. All groups were comparable for gender, age, and sex. Regarding T29C TGFβ1 gene polymorphism, prevalence of TC or CC genotypes was significantly (P<.05 higher in hypertensives with LVH than hypertensives without LVH TC and CC LVH hypertensives were characterized by a higher prevalence of subjects with microalbuminuria (P<.05 TC and CC versus TT, by increased levels of TGFβ1, procollagen type III, urinary albumin excretion, LVM, LVM/h2.7, and lower values of left ventricular ejection fraction (P<.05 TC and CC versus TT. Our data suggest that T29C TGFβ1 gene polymorphism was associated with clinical characteristics adequate to recognize a subset of LVH hypertensives with a higher severity of hypertension.

  14. Blood pressure and left ventricular hypertrophy during American-style football participation.

    Science.gov (United States)

    Weiner, Rory B; Wang, Francis; Isaacs, Stephanie K; Malhotra, Rajeev; Berkstresser, Brant; Kim, Jonathan H; Hutter, Adolph M; Picard, Michael H; Wang, Thomas J; Baggish, Aaron L

    2013-07-30

    Hypertension, a strong determinant of cardiovascular disease risk, has been documented among elite, professional American-style football (ASF) players. The risk of increased blood pressure (BP) and early adulthood hypertension among the substantially larger population of collegiate ASF athletes is not known. We conducted a prospective, longitudinal study to examine BP, the incidence of hypertension, and left ventricular remodeling among collegiate ASF athletes. Resting BP and left ventricular structure were assessed before and after a single season of competitive ASF participation in 6 consecutive groups of first-year university athletes (n=113). ASF participation was associated with significant increases in systolic BP (116±8 versus 125±13 mm Hg; Phistory of hypertension were the strongest independent predictors of postseason BP. Among linemen, there was a significant increase in the prevalence of concentric left ventricular hypertrophy (2 of 64 [3%] versus 20 of 64 [31%]; P<0.001) and change in left ventricular mass correlated with intraseason change in systolic BP (R=0.46, P<0.001). Collegiate ASF athletes may be at risk for clinically relevant increases in BP and the development of hypertension. Enhanced surveillance and carefully selected interventions may represent important opportunities to improve later-life cardiovascular health outcomes in this population.

  15. Calculation of left ventricular volumes and ejection fraction from dynamic cardiac-gated 15O-water PET/CT: 5D-PET.

    Science.gov (United States)

    Nordström, Jonny; Kero, Tanja; Harms, Hendrik Johannes; Widström, Charles; Flachskampf, Frank A; Sörensen, Jens; Lubberink, Mark

    2017-11-14

    Quantitative measurement of myocardial blood flow (MBF) is of increasing interest in the clinical assessment of patients with suspected coronary artery disease (CAD). 15 O-water positron emission tomography (PET) is considered the gold standard for non-invasive MBF measurements. However, calculation of left ventricular (LV) volumes and ejection fraction (EF) is not possible from standard 15 O-water uptake images. The purpose of the present work was to investigate the possibility of calculating LV volumes and LVEF from cardiac-gated parametric blood volume (V B ) 15 O-water images and from first pass (FP) images. Sixteen patients with mitral or aortic regurgitation underwent an eight-gate dynamic cardiac-gated 15 O-water PET/CT scan and cardiac MRI. V B and FP images were generated for each gate. Calculations of end-systolic volume (ESV), end-diastolic volume (EDV), stroke volume (SV) and LVEF were performed with automatic segmentation of V B and FP images, using commercially available software. LV volumes and LVEF were calculated with surface-, count-, and volume-based methods, and the results were compared with gold standard MRI. Using V B images, high correlations between PET and MRI ESV (r = 0.89, p  0.86, p dynamic 15 O-water PET is feasible and shows good correlation with MRI. However, the analysis method is laborious, and future work is needed for more automation to make the method more easily applicable in a clinical setting.

  16. Left Ventricular Hypertrophy: An allometric comparative analysis of different ECG markers

    International Nuclear Information System (INIS)

    Bonomini, MP; Valentinuzzi, M E; Arini, P D; Ingallina, F; Barone, V

    2011-01-01

    Allometry, in general biology, measures the relative growth of a part in relation to the whole living organism. Left ventricular hypertrophy (LVH) is the heart adaptation to excessive load (systolic or diastolic). The increase in left ventricular mass leads to an increase in the electrocardiographic voltages. Based on clinical data, we compared the allometric behavior of three different ECG markers of LVH. To do this, the allometric fit AECG δ + β (VM) relating left ventricular mass (estimated from ecocardiographic data) and ECG amplitudes (expressed as the Cornell-Voltage, Sokolow and the ECG overall voltage indexes) were compared. Besides, sensitivity and specificity for each index were analyzed. The more sensitive the ECG criteria, the better the allometric fit. In conclusion: The allometric paradigm should be regarded as the way to design new and more sensitive ECG-based LVH markers.

  17. Echocardiographic assessment of the different left ventricular geometric patterns in hypertensive patients

    Directory of Open Access Journals (Sweden)

    Delma Maria Cunha

    2001-01-01

    Full Text Available OBJECTIVE: To identiy left ventricular geometric patterns in hypertensive patients on echocardiography, and to correlate those patterns with casual blood pressure measurements and with the parameters obtained on a 24-hour ambulatory blood pressure monitoring. METHODS: We studied sixty hypertensive patients, grouped according to the Joint National Committee stages of hypertension.. Using the single- and two-dimensional Doppler Echocardiography, we analyzed the left ventricular mass and the geometric patterns through the correlation of left ventricular mass index and relative wall thickness. On ambulatory blood pressure monitoring we assessed the means and pressure loads in the different geometric patterns detected on echocardiography RESULTS: We identified three left ventricular geometric patterns: 1 concentric hypertrophy, in 25% of the patients; 2 concentric remodeling, in 25%; and 3 normal geometry, in 50%. Casual systolic blood pressure was higher in the group with concentric hypertrophy than in the other groups (p=0.001. Mean systolic pressure in the 24h, daytime and nighttime periods was also higher in patients with concentric hypertrophy, as compared to the other groups (p=0.003, p=0.004 and p=0.007. Daytime systolic load and nighttime diastolic load were higher in patients with concentric hypertrophy ( p=0.004 and p=0.01, respectively. CONCLUSIONS: Left ventricular geometric patterns show significant correlation with casual systolic blood pressure, and with means and pressure loads on ambulatory blood pressure monitoring.

  18. Structural and functional changes in the heart and clinical features of heart failure with preserved left ventricular ejection fraction in patients after myocardial infarction, comorbided with arterial hypertension

    Directory of Open Access Journals (Sweden)

    V. D. Syvolap

    2013-12-01

    class I, 32% - NYHA class II, 48% - NYHA class III and 10% have NYHA class IV. In the first group revealed a significant increase of left ventricular end diastolic volume (13,8%, p <0,05, left ventricular end systolic volume (14,9%, p <0,05 and left atrial volume index (35%, p <0,05 compared with patients from the second group. Patients from the second group had a significant increase of left ventricular mass index (15,2%, p <0,05, left ventricular posterior wall ( 12,8%, p <0,05 and interventricular septum (10%, p <0,05 compared with patients from the third group. Patients from the first group had a higher E/E ' ratio (26%, p <0,05 compared with patients from the second group. In patients from the second group revealed decreased E/A (30,8%, p <0,05, E '(35,7%, p <0,05 and increased E/E' (13, 3%, p <0,05 compared with patients from the third group. Patients after myocardial infarction with arterial hypertension and diastolic heart failure had diastolic dysfunction mainly on the type of violation of relaxation (74%. 22% of these patients had pseudonormal type of diastolic dysfunction and 4% had restrictive LV filling type. Conclusion: In patients with post-infarction cardiosclerosis and diastolic heart failure with arterial hypertension severity of clinical manifestations of heart failure correlates with left atrial volume index and markers of diastolic dysfunction such as E' and E/E'. In patients with post-infarction cardiosclerosis and arterial hypertension with diastolic heart failure had predominantly concentric hypertrophy with increased left atrial volume index and moderate left ventricular dilatation and mild diastolic dysfunction. In patients after myocardial infarction with arterial hypertension and asymptomatic diastolic dysfunction observed structural and functional changes in the type of concentric hypertrophy with thickened walls and increased left ventricular mass index.

  19. N-terminal pro B-type natriuretic peptide predicts mortality in patients with left ventricular hypertrophy.

    Science.gov (United States)

    Garcia, Santiago; Akbar, Muhammad S; Ali, Syed S; Kamdar, Forum; Tsai, Michael Y; Duprez, Daniel A

    2010-09-03

    Left ventricular hypertrophy adversely affects outcomes in patients with hypertension. Whether N-terminal pro B-type natriuretic peptide (NT-proBNP) adds incremental prognostic information in patients with hypertension and left ventricular hypertrophy (LVH) is not well established. We aimed to study the prognostic value of NT-proBNP in hypertensive patients with LVH. Echocardiography was performed in 232 patients (mean age 61±15, 102 males, 130 females) for the diagnosis of left ventricular hypertrophy. Left ventricular mass was measured according to The American Society of Echocardiography guidelines. A blood sample was taken for NT-proBNP determination. NT-proBNP levels were analyzed in quartiles after log transformation. Long term survival was established by review of electronic medical records. Arterial hypertension was present in 130 patients (56%) and left ventricular hypertrophy was present in 105 patients (45%). In patients with left ventricular hypertrophy, NT-proBNP levels predicted long term survival (Chi-square=10, p=0.01). After adjusting by age, presence of coronary artery disease, ejection fraction, diabetes status, and hypertension; patients in highest NT pro-BNP quartile were twice as likely to die when compared to patients in the lowest NT-ptoBNP quartile (OR=2.2, 95% CI=1.0-4.6, p=0.03). NT-proBNP is an independent predictor of survival in patients with hypertension and increased left ventricular mass. Copyright © 2009 Elsevier B.V. All rights reserved.

  20. Right and left ventricular performance by nuclear stethoscope

    International Nuclear Information System (INIS)

    Nishimura, T.; Uehara, T.; Hayashida, K.; Kozuka, T.

    1983-01-01

    Right and left ventricular performance by Nuclear Stethoscope using Kr-81m and Tc-99m-RBC were performed. And physiological and pharmacological interventions were also investigated for the evaluation of coronary artery diseases (CAD)

  1. An angiographic study of left- and right-ventricular function in patients with alcoholic heart and dilatation cardiomyopathy

    International Nuclear Information System (INIS)

    Savchenko, A.P.; Samko, A.N.; Smetnev, A.S.; Grudtsyn, G.V.

    1986-01-01

    An angiographic study of left- and right-ventricular function in 57 patients with alcoholic heart and dilatation cardiomyopathy demonstrated preclinical disorders of left-ventricular myocardial contractility and more marked right-ventricular changes in patients with second-stage chronic alcoholism. In cases of dilatation cardiomyopathy, left-ventricular dysfunction was predominant, while right-venricular changes were less pronouced

  2. Evaluation of right and left ventricular function during adult respiratory distress syndrom using radionuclide angiocardiography conventional and tomographic approaches

    International Nuclear Information System (INIS)

    Devaux, J.Y.; Dhainaut, J.F.; Roucayrol, J.C.; Brunol, J.

    1982-01-01

    Despite numerous experimental and clinical studies, the cardiovascular effects of mechanical ventilation with positive-end-expiratory pressure (PEEP) are unclear. Specially, the constant fall in cardiac output is not well undestood. The purpose of this study was to investigate the effects of PEEP on right and left ventricular systolic and diastolic performance before and after volume expansion using angioscintigraphy with red blood cells, in vitro labelled with 99m Tc, a reliable, non invasive method to assess right and left ventricular dimensions and global and segmental contractility. First results in patients with adult respiratory distress syndrom (ARDS) confirm the capabilities of such a method for evaluation of regional wall motion in both ventricles

  3. Assessment of global and regional left ventricular function using 64-slice multislice computed tomography and 2D echocardiography: A comparison with cardiac magnetic resonance

    International Nuclear Information System (INIS)

    Annuar, Bin Rapaee; Liew, Chee Khoon; Chin, Sze Piaw; Ong, Tiong Kiam; Seyfarth, M. Tobias; Chan, Wei Ling; Fong, Yean Yip; Ang, Choon Kiat; Lin, Naing; Liew, Houng Bang; Sim, Kui Hian

    2008-01-01

    Objectives: To compare the assessment of global and regional left ventricular (LV) function using 64-slice multislice computed tomography (MSCT), 2D echocardiography (2DE) and cardiac magnetic resonance (CMR). Methods: Thirty-two consecutive patients (mean age, 56.5 ± 9.7 years) referred for evaluation of coronary artery using 64-slice MSCT also underwent 2DE and CMR within 48 h. The global left ventricular function which include left ventricular ejection fraction (LVEF), left ventricular end diastolic volume (LVdV) and left ventricular end systolic volume (LVsV) were determine using the three modalities. Regional wall motion (RWM) was assessed visually in all three modalities. The CMR served as the gold standard for the comparison between 64-slice MSCT with CMR and 2DE with CMR. Statistical analysis included Pearson correlation coefficient, Bland-Altman plots and κ-statistics. Results: The 64-slice MSCT agreed well with CMR for assessment of LVEF (r = 0.92; p < 0.0001), LVdV (r = 0.98; p < 0.0001) and LVsV (r = 0.98; p < 0.0001). In comparison with 64-slice MSCT, 2DE showed moderate correlation with CMR for the assessment of LVEF (r = 0.84; p < 0.0001), LVdV (r = 0.83; p < 0.0001) and LVsV (r = 0.80; p < 0.0001). However in RWM analysis, 2DE showed better accuracy than 64-slice MSCT (94.3% versus 82.4%) and closer agreement (κ = 0.89 versus 0.63) with CMR. Conclusion: 64-Slice MSCT correlates strongly with CMR in global LV function however in regional LV function 2DE showed better agreement with CMR than 64-slice MSCT

  4. Assessment of global and regional left ventricular function using 64-slice multislice computed tomography and 2D echocardiography: A comparison with cardiac magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Annuar, Bin Rapaee [Faculty of Medicine, University Malaysia Sarawak (Malaysia); Department of Cardiology, Sarawak General Hospital (Malaysia)], E-mail: rannuar@fmhs.unimas.my; Liew, Chee Khoon; Chin, Sze Piaw; Ong, Tiong Kiam [Department of Cardiology, Sarawak General Hospital (Malaysia); Seyfarth, M. Tobias [Sieman Medical Solution (Germany); Chan, Wei Ling; Fong, Yean Yip; Ang, Choon Kiat [Department of Cardiology, Sarawak General Hospital (Malaysia); Lin, Naing [Universiti Sains Malaysia (Malaysia); Liew, Houng Bang; Sim, Kui Hian [Department of Cardiology, Sarawak General Hospital (Malaysia)

    2008-01-15

    Objectives: To compare the assessment of global and regional left ventricular (LV) function using 64-slice multislice computed tomography (MSCT), 2D echocardiography (2DE) and cardiac magnetic resonance (CMR). Methods: Thirty-two consecutive patients (mean age, 56.5 {+-} 9.7 years) referred for evaluation of coronary artery using 64-slice MSCT also underwent 2DE and CMR within 48 h. The global left ventricular function which include left ventricular ejection fraction (LVEF), left ventricular end diastolic volume (LVdV) and left ventricular end systolic volume (LVsV) were determine using the three modalities. Regional wall motion (RWM) was assessed visually in all three modalities. The CMR served as the gold standard for the comparison between 64-slice MSCT with CMR and 2DE with CMR. Statistical analysis included Pearson correlation coefficient, Bland-Altman plots and {kappa}-statistics. Results: The 64-slice MSCT agreed well with CMR for assessment of LVEF (r = 0.92; p < 0.0001), LVdV (r = 0.98; p < 0.0001) and LVsV (r = 0.98; p < 0.0001). In comparison with 64-slice MSCT, 2DE showed moderate correlation with CMR for the assessment of LVEF (r = 0.84; p < 0.0001), LVdV (r = 0.83; p < 0.0001) and LVsV (r = 0.80; p < 0.0001). However in RWM analysis, 2DE showed better accuracy than 64-slice MSCT (94.3% versus 82.4%) and closer agreement ({kappa} = 0.89 versus 0.63) with CMR. Conclusion: 64-Slice MSCT correlates strongly with CMR in global LV function however in regional LV function 2DE showed better agreement with CMR than 64-slice MSCT.

  5. Assessment of global and regional left ventricular function using 64-slice multislice computed tomography and 2D echocardiography: a comparison with cardiac magnetic resonance.

    Science.gov (United States)

    Annuar, Bin Rapaee; Liew, Chee Khoon; Chin, Sze Piaw; Ong, Tiong Kiam; Seyfarth, M Tobias; Chan, Wei Ling; Fong, Yean Yip; Ang, Choon Kiat; Lin, Naing; Liew, Houng Bang; Sim, Kui Hian

    2008-01-01

    To compare the assessment of global and regional left ventricular (LV) function using 64-slice multislice computed tomography (MSCT), 2D echocardiography (2DE) and cardiac magnetic resonance (CMR). Thirty-two consecutive patients (mean age, 56.5+/-9.7 years) referred for evaluation of coronary artery using 64-slice MSCT also underwent 2DE and CMR within 48h. The global left ventricular function which include left ventricular ejection fraction (LVEF), left ventricular end diastolic volume (LVdV) and left ventricular end systolic volume (LVsV) were determine using the three modalities. Regional wall motion (RWM) was assessed visually in all three modalities. The CMR served as the gold standard for the comparison between 64-slice MSCT with CMR and 2DE with CMR. Statistical analysis included Pearson correlation coefficient, Bland-Altman plots and kappa-statistics. The 64-slice MSCT agreed well with CMR for assessment of LVEF (r=0.92; p<0.0001), LVdV (r=0.98; p<0.0001) and LVsV (r=0.98; p<0.0001). In comparison with 64-slice MSCT, 2DE showed moderate correlation with CMR for the assessment of LVEF (r=0.84; p<0.0001), LVdV (r=0.83; p<0.0001) and LVsV (r=0.80; p<0.0001). However in RWM analysis, 2DE showed better accuracy than 64-slice MSCT (94.3% versus 82.4%) and closer agreement (kappa=0.89 versus 0.63) with CMR. 64-Slice MSCT correlates strongly with CMR in global LV function however in regional LV function 2DE showed better agreement with CMR than 64-slice MSCT.

  6. Effect of hydration status on atrial and ventricular volumes and function in healthy adult volunteers

    Energy Technology Data Exchange (ETDEWEB)

    Schantz, Daryl I. [The Hospital for Sick Children, The Labatt Family Heart Centre in the Department of Paediatrics, Toronto, ON (Canada); University of Manitoba, Variety Children' s Heart Centre, Winnipeg, MB (Canada); Dragulescu, Andreea [The Hospital for Sick Children, The Labatt Family Heart Centre in the Department of Paediatrics, Toronto, ON (Canada); Memauri, Brett [University of Manitoba, Department of Radiology, St. Boniface General Hospital, Winnipeg, MB (Canada); Grotenhuis, Heynric B. [The Hospital for Sick Children, The Labatt Family Heart Centre in the Department of Paediatrics, Toronto, ON (Canada); Wilhelmina Children' s Hospital, Utrecht (Netherlands); Seed, Mike; Grosse-Wortmann, Lars [The Hospital for Sick Children, The Labatt Family Heart Centre in the Department of Paediatrics, Toronto, ON (Canada); The Hospital for Sick Children, Department of Diagnostic Imaging, Toronto, ON (Canada)

    2016-10-15

    Assessment of cardiac chamber volumes is a fundamental part of cardiac magnetic resonance (CMR) imaging. While the effects of inter- and intraobserver variability have been studied and have a recognized effect on the comparability of serial cardiac MR imaging studies, the effect of differences in hydration status has not been evaluated. To evaluate the effects of volume administration on cardiac chamber volumes. Thirteen healthy adults underwent a baseline cardiac MR to evaluate cardiac chamber volumes after an overnight fast. They were then given two saline boluses of 10 ml/kg of body weight and the cardiac MR was repeated immediately after each bolus. From the baseline scan to the final scan there was a significant increase in all four cardiac chamber end-diastolic volumes. Right atrial volumes increased 8.0%, from 61.1 to 66.0 ml/m2 (P<0.001), and left atrial volumes increased 10.0%, from 50.0 to 55.0 ml/m2 (P<0.001). Right ventricular volumes increased 6.0%, from 91.1 to 96.5 ml/m2 (P<0.001), and left ventricular volumes increased 3.2%, from 87.0 to 89.8 ml/m2 (P<0.001). Hydration status has a significant effect on the end-diastolic volumes of all cardiac chambers assessed by cardiac MR. Thus, hydration represents a ''variable'' that should be taken into account when assessing cardiac chamber volumes, especially when performing serial imaging studies in a patient. (orig.)

  7. Effect of hydration status on atrial and ventricular volumes and function in healthy adult volunteers

    International Nuclear Information System (INIS)

    Schantz, Daryl I.; Dragulescu, Andreea; Memauri, Brett; Grotenhuis, Heynric B.; Seed, Mike; Grosse-Wortmann, Lars

    2016-01-01

    Assessment of cardiac chamber volumes is a fundamental part of cardiac magnetic resonance (CMR) imaging. While the effects of inter- and intraobserver variability have been studied and have a recognized effect on the comparability of serial cardiac MR imaging studies, the effect of differences in hydration status has not been evaluated. To evaluate the effects of volume administration on cardiac chamber volumes. Thirteen healthy adults underwent a baseline cardiac MR to evaluate cardiac chamber volumes after an overnight fast. They were then given two saline boluses of 10 ml/kg of body weight and the cardiac MR was repeated immediately after each bolus. From the baseline scan to the final scan there was a significant increase in all four cardiac chamber end-diastolic volumes. Right atrial volumes increased 8.0%, from 61.1 to 66.0 ml/m2 (P<0.001), and left atrial volumes increased 10.0%, from 50.0 to 55.0 ml/m2 (P<0.001). Right ventricular volumes increased 6.0%, from 91.1 to 96.5 ml/m2 (P<0.001), and left ventricular volumes increased 3.2%, from 87.0 to 89.8 ml/m2 (P<0.001). Hydration status has a significant effect on the end-diastolic volumes of all cardiac chambers assessed by cardiac MR. Thus, hydration represents a ''variable'' that should be taken into account when assessing cardiac chamber volumes, especially when performing serial imaging studies in a patient. (orig.)

  8. Quantitative assessment of left ventricular systolic wall thickening using multidetector computed tomography

    DEFF Research Database (Denmark)

    Kristensen, Thomas S; Kofoed, Klaus F; Møller, Daniel V

    2009-01-01

    BACKGROUND: Multidetector computed tomography (MDCT) of the heart provides both anatomical and functional information. The objective of this study was to evaluate the accuracy of quantitative assessment of left ventricular contractile function in relation to two-dimensional transthoracic echocard......BACKGROUND: Multidetector computed tomography (MDCT) of the heart provides both anatomical and functional information. The objective of this study was to evaluate the accuracy of quantitative assessment of left ventricular contractile function in relation to two-dimensional transthoracic...... echocardiography (TTE). MATERIALS AND METHODS: Sixty-four patients with known or suspected coronary artery disease underwent ECG-gated 64-slice MDCT and TTE. Regional left ventricular contractile function was measured by percent systolic wall thickening (SWT) in 16 myocardial segments using MDCT, and compared...

  9. Influence of White-Coat Hypertension on Left Ventricular Deformation 2- and 3-Dimensional Speckle Tracking Study.

    Science.gov (United States)

    Tadic, Marijana; Cuspidi, Cesare; Ivanovic, Branislava; Ilic, Irena; Celic, Vera; Kocijancic, Vesna

    2016-03-01

    We sought to compare left ventricular deformation in subjects with white-coat hypertension to normotensive and sustained hypertensive patients. This cross-sectional study included 139 untreated subjects who underwent 24-hour ambulatory blood pressure monitoring and completed 2- and 3-dimensional examination. Two-dimensional left ventricular multilayer strain analysis was also performed. White-coat hypertension was diagnosed if clinical blood pressure was elevated and 24-hour blood pressure was normal. Our results showed that left ventricular longitudinal and circumferential strains gradually decreased from normotensive controls across subjects with white-coat hypertension to sustained hypertensive group. Two- and 3-dimensional left ventricular radial strain, as well as 3-dimensional area strain, was not different between groups. Two-dimensional left ventricular longitudinal and circumferential strains of subendocardial and mid-myocardial layers gradually decreased from normotensive control to sustained hypertensive group. Longitudinal and circumferential strains of subepicardial layer did not differ between the observed groups. We concluded that white-coat hypertension significantly affects left ventricular deformation assessed by 2-dimensional traditional strain, multilayer strain, and 3-dimensional strain. © 2016 American Heart Association, Inc.

  10. Characterization of the Left-Sided Substrate in Arrhythmogenic Right Ventricular Cardiomyopathy.

    Science.gov (United States)

    Berte, Benjamin; Denis, Arnaud; Amraoui, Sana; Yamashita, Seigo; Komatsu, Yuki; Pillois, Xavier; Sacher, Frédéric; Mahida, Saagar; Wielandts, Jean-Yves; Sellal, Jean-Marc; Frontera, Antonio; Al Jefairi, Nora; Derval, Nicolas; Montaudon, Michel; Laurent, François; Hocini, Mélèze; Haïssaguerre, Michel; Jaïs, Pierre; Cochet, Hubert

    2015-12-01

    The correlates of left ventricular (LV) substrate in arrhythmogenic right ventricular (RV) cardiomyopathy are largely unknown. Thirty-two patients with arrhythmogenic RV cardiomyopathy (47±14 years; 6 women) were included. RV and LV dysplasia were defined from multidetector computed tomography and cardiac magnetic resonance imaging. Arrhythmias were characterized as right-sided or left-sided on 12-lead ECG recordings at baseline and during isoproterenol testing. In 14 patients, the imaging substrate was compared with voltage mapping and local abnormal ventricular activity. Imaging abnormalities were found in 32 (100%) and 21 (66%) patients on the RV and LV, respectively, intramyocardial fat on multidetector computed tomography being the most sensitive feature. LV involvement related to none of the Task Force criteria. Right-sided arrhythmias were more frequent than left-sided arrhythmias (P=0.003) although the latter were more frequent in case of LV involvement (P=0.02). The agreement between low voltage and fat on multidetector computed tomography was high on the RV when using either endocardial unipolar or epicardial bipolar data (κ=0.82 and κ=0.78, respectively) but lower on the LV (κ=0.54 for epicardial bipolar). LV local abnormal ventricular activity was found in all patients with LV involvement, and none of the others. The density of local abnormal ventricular activity within fat areas was similar between the RV and LV (P=0.57). LV substrate is frequent in arrhythmogenic RV cardiomyopathy, but poorly identified by current diagnostic strategies. Left-sided arrhythmias are more frequent in case of LV involvement. LV fat hosts the same density of local abnormal ventricular activity as RV fat, but is less efficiently detected by voltage mapping. These results support the need for alternative diagnostic strategies to identify LV dysplasia. © 2015 American Heart Association, Inc.

  11. Calculation of left ventricular volumes and ejection fraction from dynamic cardiac-gated 15O-water PET/CT: 5D-PET

    Directory of Open Access Journals (Sweden)

    Jonny Nordström

    2017-11-01

    Full Text Available Abstract Background Quantitative measurement of myocardial blood flow (MBF is of increasing interest in the clinical assessment of patients with suspected coronary artery disease (CAD. 15O-water positron emission tomography (PET is considered the gold standard for non-invasive MBF measurements. However, calculation of left ventricular (LV volumes and ejection fraction (EF is not possible from standard 15O-water uptake images. The purpose of the present work was to investigate the possibility of calculating LV volumes and LVEF from cardiac-gated parametric blood volume (V B 15O-water images and from first pass (FP images. Sixteen patients with mitral or aortic regurgitation underwent an eight-gate dynamic cardiac-gated 15O-water PET/CT scan and cardiac MRI. V B and FP images were generated for each gate. Calculations of end-systolic volume (ESV, end-diastolic volume (EDV, stroke volume (SV and LVEF were performed with automatic segmentation of V B and FP images, using commercially available software. LV volumes and LVEF were calculated with surface-, count-, and volume-based methods, and the results were compared with gold standard MRI. Results Using V B images, high correlations between PET and MRI ESV (r = 0.89, p  0.86, p < 0.001. Conclusion Calculation of LV volumes and LVEF from dynamic 15O-water PET is feasible and shows good correlation with MRI. However, the analysis method is laborious, and future work is needed for more automation to make the method more easily applicable in a clinical setting.

  12. Comparison of left and right ventricular ejection and filling parameters by fast cine MR imaging in breath-hold technique: clinical study of 42 patients with cardiomyopathy and coronary heart disease

    International Nuclear Information System (INIS)

    Rominger, M.B.; Bachmann, G.F.; Geuer, M.; Puzik, M.; Rau, W.S.; Ricken, W.W.

    1999-01-01

    Purpose: Quantification of left and right ventricular filling and ejection of localized and diffuse heart diseases with fast cine MR imaging in breath-hold technique. Methods: 42 patients (14 idiopathic dilated cardiomyopathies (DCM), 13 hypertrophic cardiomyopathies (HCM) and 15 coronary artery diseases (CAD)) and 10 healthy volunteers were examined. Time-volume-curves of three left ventricular and one right ventricular slices were evaluated and peak ejection and filling rates (PER, PFR end-diastolic volume (EDV)/s) time to PER and PFR (TPER, TPFR ms) and time of end-systole (TSYS in % RR-intervall) were calculated. Results: There were significant regional and left-/right-sided differences of the filling and ejection of both ventricles within and between the different groups. In DCM the left ventricular PFR was reduced (DCM 3.1 EDV/s; volunteers 4.9 EDV/s) and Z-SYS prolonged (DCM 50.1%; volunteers 35.4%). In CAD there were localized decreased filling rates in comparison to the normal volunteer group (left ventricle: basal: 2.9 and 6.3 EDV/s, apical: 4.4 and 6.3 EDV/s; right ventricle: 3.6 and 5.7 EDV/s). HCM typically showed an isovolumetric lengthening of the endsystole. Conclusions: Cardiac MR imaging in breath-hold technique is suitable for measuring contraction and relaxation disturbances of localized and diffuse heart diseases by means of ejection and filling volume indices. (orig.) [de

  13. Left ventricular structural and functional characteristics in Cushing's syndrome.

    Science.gov (United States)

    Muiesan, Maria Lorenza; Lupia, Mario; Salvetti, Massimo; Grigoletto, Consuelo; Sonino, Nicoletta; Boscaro, Marco; Rosei, Enrico Agabiti; Mantero, Franco; Fallo, Francesco

    2003-06-18

    This study was designed to evaluate left ventricular (LV) anatomy and function in patients with Cushing's syndrome. A high prevalence of LV hypertrophy and concentric remodeling has been reported in Cushing's syndrome, although no data have been reported on LV systolic and diastolic function. Forty-two consecutive patients with Cushing's syndrome and 42 control subjects, matched for age, gender, and blood pressure, were studied. Left ventricular mass index (LVMI) and relative wall thickness (RWT) were measured by echocardiography, endocardial and midwall fractional shortening (FS) were assessed, and diastolic filling was measured by Doppler transmitral flow. The RWT was significantly greater in Cushing patients than in controls. Left ventricular hypertrophy and concentric remodeling were observed in 10 and 26 patients with Cushing's syndrome, respectively. In Cushing patients, midwall FS was significantly reduced compared with controls (16.2 +/- 3% vs. 21 +/- 4.5%, p = 0.01). The ratio of transmitral E and A flow velocities was reduced and E deceleration time was prolonged in Cushing patients compared with controls (p = 0.03 and p < 0.001, respectively). In patients with Cushing's syndrome, cardiac structural changes are associated with reduced midwall systolic performance and with diastolic dysfunction that may contribute to the high risk of cardiovascular events observed in these patients.

  14. On the calculation of principle curvatures of the left-ventricular surfaces.

    Science.gov (United States)

    Claus, Piet; Choi, Hon Fai; D'hooge, Jan; Rademakers, Frank E

    2008-01-01

    A local description of the shape of the left ventricle is relevant in assessing the process of adverse ventricular remodeling, associated with most cardiac pathologies, and in monitoring reverse remodeling by therapy. To quantify local shape of the left ventricle, one can calculate the curvature of its epicardial or endocardial surface. The 3D geometry of the heart and especially the ventricles, can typically be described using finite element meshes. From a mathematical point of view these meshes provide a local parametrization of the surface in the 3-dimensional space. We discuss the analytic derivation of the principle curvatures of the left-ventricular surfaces given their smooth finite-element meshes and apply this derivation to assess the regional shape of the normal porcine left ventricle.

  15. Effects of Propranolol on the Left Ventricular Volume of Normal Subjects During CT Coronary Angiography

    International Nuclear Information System (INIS)

    Mo, Yuan Heng; Jaw, Fu Shan; Wang, Yung Cheng; Jeng, Chin Ming; Peng, Shinn Forng

    2011-01-01

    The purpose of this study is to determine the effects of propranolol on the left ventricular (LV) volume during CT coronary angiography. The LV volume of 252 normal Chinese subjects (126 subjects with propranolol medication and 126 age- and gender-matched Chinese subjects without medication) was estimated using 64 slices multi-detector CT (MDCT). The heart rate difference was analyzed by the logistic linear regression model with variables that included gender, age, body height, body weight, systolic blood pressure (SBP), diastolic blood pressure (DBP) and the dosage of propranolol. The following global LV functional parameters were calculated: the real-end diastolic volume (EDV), the real-end systolic volume (ESV) and the real-ejection fraction (EF). The female subjects had a greater decrease of heart rate after taking propranolol. The difference of heart rate was negatively correlated with the dosage of propranolol. The real-EDV, the real-ESV and the real-EF ranged from 48.1 to 109 mL/m2, 6.1 to 57.1 mL/m2 and 41% to 88%, respectively. There was no significant difference in the SBP and DBP between the groups without and with propranolol medication (123 ± 17 and 80 ± 10 mmHg; 120 ± 14 and 80 ± 11 mmHg, respectively). The real-EDV showed no significant difference between these two groups, but the real-ESV and real-EF showed significant differences between these two groups (69.4 ± 9.3 and 70.6 ± 8.9 mL/m2; 23.5 ± 5.7 and 25.6 ± 3.7 mL/m2, 66.5 ± 5.1% and 63.5 ± 4.6%, respectively). The difference of heart rate is significantly influenced by gender and the dosage of propranolol. Propranolol will also increase the ESV, which contributes to a decreased EF, while the SBP, DBP and EDV are not statistically changed.

  16. Patterns of left ventricular remodeling among patients with essential and secondary hypertension

    OpenAIRE

    Radulescu,Dan; Stoicescu,Laurentiu; Buzdugan,Elena; Donca,Valer

    2013-01-01

    Background: High blood pressure causes left ventricular hypertrophy, which is a negative prognostic factor among hypertensive patients. Aim: To assess left ventricular geometric remodeling patterns in patients with essential hypertension or with hypertension secondary to parenchymal renal disease. Material and Methods: We analyzed data from echocardiograms performed in 250patients with essential hypertension (150 females) and 100 patients with secondary hypertension (60 females). The interven...

  17. Normal left ventricular wall motion measured with two-dimensional myocardial tagging

    DEFF Research Database (Denmark)

    Qi, P; Thomsen, C; Ståhlberg, F

    1993-01-01

    contraction towards the center of the left ventricle, a motion of the base of the heart towards the apex, and a rotation of the left ventricle around its long axis. The direction of left ventricular rotation changed from early systole to late systole. The base and middle levels of the left ventricle rotated...

  18. Estimation of left ventricular blood flow parameters: clinical application of patient-specific CFD simulations from 4D echocardiography

    Science.gov (United States)

    Larsson, David; Spühler, Jeannette H.; Günyeli, Elif; Weinkauf, Tino; Hoffman, Johan; Colarieti-Tosti, Massimiliano; Winter, Reidar; Larsson, Matilda

    2017-03-01

    Echocardiography is the most commonly used image modality in cardiology, assessing several aspects of cardiac viability. The importance of cardiac hemodynamics and 4D blood flow motion has recently been highlighted, however such assessment is still difficult using routine echo-imaging. Instead, combining imaging with computational fluid dynamics (CFD)-simulations has proven valuable, but only a few models have been applied clinically. In the following, patient-specific CFD-simulations from transthoracic dobutamin stress echocardiography have been used to analyze the left ventricular 4D blood flow in three subjects: two with normal and one with reduced left ventricular function. At each stress level, 4D-images were acquired using a GE Vivid E9 (4VD, 1.7MHz/3.3MHz) and velocity fields simulated using a presented pathway involving endocardial segmentation, valve position identification, and solution of the incompressible Navier-Stokes equation. Flow components defined as direct flow, delayed ejection flow, retained inflow, and residual volume were calculated by particle tracing using 4th-order Runge-Kutta integration. Additionally, systolic and diastolic average velocity fields were generated. Results indicated no major changes in average velocity fields for any of the subjects. For the two subjects with normal left ventricular function, increased direct flow, decreased delayed ejection flow, constant retained inflow, and a considerable drop in residual volume was seen at increasing stress. Contrary, for the subject with reduced left ventricular function, the delayed ejection flow increased whilst the retained inflow decreased at increasing stress levels. This feasibility study represents one of the first clinical applications of an echo-based patient-specific CFD-model at elevated stress levels, and highlights the potential of using echo-based models to capture highly transient flow events, as well as the ability of using simulation tools to study clinically complex

  19. Comparing impedance cardiography and echocardiography in the assessment of reduced left ventricular systolic function

    DEFF Research Database (Denmark)

    Kaszuba, Elzbieta; Scheel, Sergej; Odeberg, Håkan

    2013-01-01

    An early and accurate diagnosis of chronic heart failure is a big challenge for a general practitioner. Assessment of left ventricular function is essential for the diagnosis of heart failure and the prognosis. A gold standard for identifying left ventricular function is echocardiography...

  20. Measurement of effective left ventricular ejection fraction by radiocardiography associated with cardiac chamber scanning

    Energy Technology Data Exchange (ETDEWEB)

    de Vernejoul, P; Fauchet, M; Rimbert, J -N; Gambini, D; Agnely, J [Hopital Necker-Enfants-Malades, 75 - Paris (France)

    1976-03-01

    Left ventricular ejection fraction is usually measured by cineangiocardiography. When radiocardiography and cardiac chamber scanning are associated, it allows an effective left ventricular ejection fraction assessment. Ejection fractions calculated by both methods are the same in normal subjects. They are different in the case of left valvular heart disease with insufficiency. The whole regurgitation fraction can be calculated from this difference.

  1. Measurement of effective left ventricular ejection fraction by radiocardiography associated with cardiac chamber scanning

    International Nuclear Information System (INIS)

    Vernejoul, Pierre de; Fauchet, Michel; Rimbert, J.-N.; Gambini, Denis; Agnely, Jacqueline

    1976-01-01

    Left ventricular ejection fraction is usually measured by cineangiocardiography. When radiocardiography and cardiac chamber scanning are associated, it allows an effective left ventricular ejection fraction assessment. Ejection fractions calculated by both methods are the same in normal subjects. They are different in the case of left valvular heart disease with insufficiency. The whole regurgitation fraction can be calculated from this difference [fr

  2. Left ventricular dimensions, systolic functions, and mass in term neonates with symmetric and asymmetric intrauterine growth restriction.

    Science.gov (United States)

    Cinar, Bahar; Sert, Ahmet; Gokmen, Zeynel; Aypar, Ebru; Aslan, Eyup; Odabas, Dursun

    2015-02-01

    Previous studies have demonstrated structural changes in the heart and cardiac dysfunction in foetuses with intrauterine growth restriction. There are no available data that evaluated left ventricular dimensions and mass in neonates with symmetric and asymmetric intrauterine growth restriction. Therefore, we aimed to evaluate left ventricular dimensions, systolic functions, and mass in neonates with symmetric and asymmetric intrauterine growth restriction. We also assessed associated maternal risk factors, and compared results with healthy appropriate for gestational age neonates. In all, 62 asymmetric intrauterine growth restriction neonates, 39 symmetric intrauterine growth restriction neonates, and 50 healthy appropriate for gestational age neonates were evaluated by transthoracic echocardiography. The asymmetric intrauterine growth restriction group had significantly lower left ventricular end-systolic and end-diastolic diameters and posterior wall diameter in systole and diastole than the control group. The symmetric intrauterine growth restriction group had significantly lower left ventricular end-diastolic diameter than the control group. All left ventricular dimensions were lower in the asymmetric intrauterine growth restriction neonates compared with symmetric intrauterine growth restriction neonates (p>0.05), but not statistically significant except left ventricular posterior wall diameter in diastole (3.08±0.83 mm versus 3.54 ±0.72 mm) (pintrauterine growth restriction groups had significantly lower relative posterior wall thickness (0.54±0.19 versus 0.48±0.13 versus 0.8±0.12), left ventricular mass (9.8±4.3 g versus 8.9±3.4 g versus 22.2±5.7 g), and left ventricular mass index (63.6±29.1 g/m2 versus 54.5±24.4 g/m2 versus 109±28.8 g/m2) when compared with the control group. Our study has demonstrated that although neonates with both symmetric and asymmetric intrauterine growth restriction had lower left ventricular dimensions, relative

  3. Association of heart failure hospitalizations with combined electrocardiography and echocardiography criteria for left ventricular hypertrophy

    DEFF Research Database (Denmark)

    Gerdts, Eva; Okin, Peter M; Boman, Kurt

    2012-01-01

    The value of performing echocardiography in hypertensive patients with electrocardiographic left ventricular hypertrophy (LVH) is uncertain.......The value of performing echocardiography in hypertensive patients with electrocardiographic left ventricular hypertrophy (LVH) is uncertain....

  4. Implantation of a HeartMate II left ventricular assist device via left thoracotomy.

    Science.gov (United States)

    Cho, Yang Hyun; Deo, Salil V; Schirger, John A; Pereira, Naveen L; Stulak, John M; Park, Soon J

    2012-11-01

    Left thoracotomy was used as an approach for the implantation of pulsatile ventricular assist devices. Avoiding the standard approach of median sternotomy is attractive in patients undergoing complicated redo cardiac surgery, especially with prior mediastinal radiation. We report a case of the use of left thoracotomy for the implantation of the HeartMate II axial-flow pump. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Accuracy of gated equilibrium radioventriculography in measuring left ventricular function in dogs

    International Nuclear Information System (INIS)

    Valette, H.; Bourguignon, M.H.; Apoil, E.; Syrota, A.; Moyse, D.; Wise, R.A.; Buchanan, J.W.; Wagner, H.N. Jr.

    1988-01-01

    To assess the precision of gated equilibrium radioventriculography in measuring changes in left ventricular stroke volume (LVSV), we studied five dogs each with a chronically implanted electromagnetic flowmeter on the ascending aorta. Per cent changes in left ventricular stroke counts (LVSC) were compared to those in LVSV following acute changes induced by positive end respiratory pressure. We have compared LVSCs calculated in five different ways: (1) Manual outlining of LV region of interest (LVROI), either single fixed enddiastolic (ED) ROI or ED and end-systolic (ES) ROIs with the aid of functional images (first harmonic of Fourier analysis); (2-5) automatic outlining of LV ROI (the algorithm generated 30 profiles on which the maximum of second derivative delineated the LV edges) was performed either on ED image or both ED and ES images. For these four methods a crescent-shaped ROI for background correction was manually drawn at the border of the LV ROI. The fifth method used an automatically drawn single fixed LVED ROI with interpolative background substraction (IBS) between LV and RV edges. LVSC changes, calculated with the IBS method, correlated better with LVSV changes than the other four methods. Thus assessment of small LVSC changes is highly processing-dependent. (author)

  6. Clinical application of a right ventricular pressure-volume loop determined by gated blood-pool imaging and simultaneously measured right ventricular pressure

    International Nuclear Information System (INIS)

    Yasue, Takao; Watanabe, Sachiro; Sugishita, Nobuyoshi; Tanaka, Tsutomu; Yokoyama, Hideo

    1983-01-01

    The data obtained by ECG-gated radionuclide angiography were collected simultaneously with right ventricular pressure and thermal cardiac output (CO) obtained by a Swan-Ganz catheter in Scintipac 1200 (Shimazu Co) in order to create a right ventricular pressure-volume (RV P-V) loop. Subjects consisted of 15 patients with old myocardial infarction (MI group), seven with angina pectoris (AP group), six with congestive cardiomyopathy (CCM group) and five with neurocirculatory asthenia (NCA group). Right ventricular end-diastolic volume (RVEDV) was calculated as RVEDV = CO/(EF x HR) (CO = cardiac output; HR = heart rate). Systolic work (W sub(S)), diastolic work (W sub(D)) and net work (W sub(N)) were calculated from a RV P-V loop by Simpson's method. The measurements were performed before and 5 min after sublingual administration of nitroglycerin (NG) (0.3 mg). The results were as follows: 1. RV P-V loops shifted towards the left lower part of the P-V plane after sublingual administration of nitroglycerin, indicating the reduction of pressure and volume of the right ventricle. 2. Right ventricular ejection fraction (RVEF) in the MI, AP and CCM groups showed smaller values than that of the NCA group. 3. Right ventricular end-diastolic volume index (RVEDVI) showed a converse relation with RVEF. 4. Cardiac index in all groups decreased after NG and a statistical significance was seen in the MI, AP and NCA groups (p<0.05). 5. RV W sub(S), RV W sub(D) and RV W sub(N) showed no difference among each groups in the control state, and significantly decreased after NG. We conclude that the present method using RV P-V loop might be useful as a noninvasive bedside monitoring and permits the evaluation of RV function in a clinical setting

  7. Left ventricular hypertrophy in renal failure review | Arodiwe ...

    African Journals Online (AJOL)

    Renal failure is becoming increasingly common in our enironment. Advances in management like availability of dialysis and transplantation is prolonging the live of patients. As a consequence complication are increasingly being encountered. Cardiovascular complication is one of the commonest; and left ventricular ...

  8. Left ventricular pseudoaneurysm versus aneurysm a diagnosis dilemma

    Directory of Open Access Journals (Sweden)

    Samarjit Bisoyi

    2016-01-01

    Full Text Available Free wall rupture of the left ventricle (LV is a rare but life-threatening complication of acute myocardial infaction. Very rarely such rupture may be contained by the adhering pericardium creating a pseudoaneurysm. This condition warrants for an emergency surgery. Left ventricular aneurysm is the discrete thinning of the ventricular wall (<5 mm with akinetic or dyskinetic wall motion causing an out-pouching of the ventricle. Given the propensity for pseudoaneurysms to rupture leading to cardiac tamponade, shock, and death, compared with a more benign natural history for true aneurysms, accurate diagnosis of these conditions is important. True aneurysm, usually, calls for an elective surgery. Clinically differentiating the two conditions remains a challenge. We report the case of a patient with LV pseudoaneurysm, initially diagnosed as true aneurysm at our institution. We have attempted to review the existing literature and discussed the characteristic findings of each entity.

  9. Left ventricular aneurysm in short axis: a comparison of magnetic resonance, ultrasound and thallium-201 SPECT images

    International Nuclear Information System (INIS)

    Ahmad, M.; Johnson, R.F. Jr.; Fawcett, H.D.; Schreiber, M.H.

    1987-01-01

    Short axis magnetic resonance images of a left ventricular aneurysm were compared to similar views obtained by echocardiography and by thallium-201 single photon emission computed tomography. Images of the dyskinetic left ventricular apex and the contractile left ventricular base were analyzed and compared. Unlike the previously reported orthogonal plane magnetic resonance images, short axis imaging provided representative and quantitative information in views comparable to those obtained by standard noninvasive imaging techniques. These data indicate that short axis magnetic resonance imaging is capable of identifying and sizing the aneurysmal and the residual segments of the left ventricle. The findings may be of prognostic value in patients with left ventricular aneurysm

  10. Longitudinal strain bull's eye plot patterns in patients with cardiomyopathy and concentric left ventricular hypertrophy.

    Science.gov (United States)

    Liu, Dan; Hu, Kai; Nordbeck, Peter; Ertl, Georg; Störk, Stefan; Weidemann, Frank

    2016-05-10

    Despite substantial advances in the imaging techniques and pathophysiological understanding over the last decades, identification of the underlying causes of left ventricular hypertrophy by means of echocardiographic examination remains a challenge in current clinical practice. The longitudinal strain bull's eye plot derived from 2D speckle tracking imaging offers an intuitive visual overview of the global and regional left ventricular myocardial function in a single diagram. The bull's eye mapping is clinically feasible and the plot patterns could provide clues to the etiology of cardiomyopathies. The present review summarizes the longitudinal strain, bull's eye plot features in patients with various cardiomyopathies and concentric left ventricular hypertrophy and the bull's eye plot features might serve as one of the cardiac workup steps on evaluating patients with left ventricular hypertrophy.

  11. The application of phase analysis of gated myocardial perfusion imaging to assess left ventricular mechanical dyssynchrony in cardiovascular disease

    International Nuclear Information System (INIS)

    Wang Jianfeng; Wang Yuetao

    2013-01-01

    Left ventricular mechanical dyssynchrony is closely related to the severity of cardiovascular disease, it is essential to assess left ventricular mechanical dyssynchrony accurately for early prediction of adverse cardiac events and prognosis assessment of the cardiac resynchronization therapy. As a new technology to assess left ventricular mechanical dyssynchrony, the phase analysis of gated myocardial perfusion imaging (GMPI) can get both quantitative indicators of regional myocardial perfusion, evaluation of regional myocardial viability and scar tissue, as well as quantitative analysis of left ventricular function and left ventricular mechanical synchrony, it has broad application prospects in cardiovascular disease to assess left ventricular mechanical dyssynchrony and prognosis assessment. This review mainly described the applications of GMPI phase analysis in the cardiovascular disease. (authors)

  12. Ventricular fibrillation in an ambulatory patient supported by a left ventricular assist device: highlighting the ICD controversy.

    Science.gov (United States)

    Boilson, Barry A; Durham, Lucian A; Park, Soon J

    2012-01-01

    Left ventricular assist devices (LVADs) provide an effective means of managing advanced pump failure as a means of bridging to cardiac transplantation or as permanent therapy. Although ventricular arrhythmias remain common post-LVAD implantation, such therapy may allow malignant arrhythmias to be tolerated hemodynamically. This report describes the clinical findings in a patient who had likely been in a ventricular tachyarrhythmia for several days and presented in ventricular fibrillation, ambulatory, and mentating normally. This report, with previous similar reports, is additive to the body of evidence that LVADs alter the physiologic impact of ventricular arrhythmias in advanced heart failure and highlights the need for thoughtful programming of implantable cardioverter defibrillator therapies in these patients.

  13. Assessment of the left ventricular function with the nuclear stethoscope

    Energy Technology Data Exchange (ETDEWEB)

    Tarkowska, A.; Adam, W.E.; Bitter, F.

    1980-08-01

    The evaluation of the left ventricular function with the Nuclear Stethoscope was performed on 27 patients with heart diseases. The reproducibility of the measurements was good. Repetitions of EF, ER and EDV estimations yielded errors of 2.63%, 1.45% and 0.31%. The comparison with the results of camera ventriculography showed a good agreement of EF, contraction velocity parameters and relaxation velocity parameters, with a cor. coeff. of greater or equal to 0.750. A particularly high correlation was found between the NS EF and NS ER (r = 0.968). It was concluded that the Nuclear Stethoscope provides a reliable evaluation of left ventricular function.

  14. Assessment of the left ventricular function with the nuclear stethoscope

    International Nuclear Information System (INIS)

    Tarkowska, A.; Adam, W.E.; Bitter, F.

    1980-01-01

    The evaluation of the left ventricular function with the Nuclear Stethoscope was performed on 27 patients with heart diseases. The reproducibility of the measurements was good. Repetitions of EF, ER and EDV estimations yielded errors of 2.63%, 1.45% and 0.31%. The comparison with the results of camera ventriculography showed a good agreement of EF, contraction velocity parameters and relaxation velocity parameters, with a cor. coeff. of greater or equal to 0.750. A particularly high correlation was found between the NS EF and NS ER (r = 0.968). It was concluded that the Nuclear Stethoscope provides a reliable evaluation of left ventricular function. (orig.) [de

  15. The effect of heart failure and left ventricular assist device treatment on right ventricular mechanics: a computational study.

    Science.gov (United States)

    Park, Jun I K; Heikhmakhtiar, Aulia Khamas; Kim, Chang Hyun; Kim, Yoo Seok; Choi, Seong Wook; Song, Kwang Soup; Lim, Ki Moo

    2018-05-22

    Although it is important to analyze the hemodynamic factors related to the right ventricle (RV) after left ventricular assist device (LVAD) implantation, previous studies have focused only on the alteration of the ventricular shape and lack quantitative analysis of the various hemodynamic parameters. Therefore, we quantitatively analyzed various hemodynamic parameters related to the RV under normal, heart failure (HF), and HF incorporated with continuous flow LVAD therapy by using a computational model. In this study, we combined a three-dimensional finite element electromechanical model of ventricles, which is based on human ventricular morphology captured by magnetic resonance imaging (MRI) with a lumped model of the circulatory system and continuous flow LVAD function in order to construct an integrated model of an LVAD implanted-cardiovascular system. To induce systolic dysfunction, the magnitude of the calcium transient function under HF condition was reduced to 70% of the normal value, and the time constant was reduced by 30% of the normal value. Under the HF condition, the left ventricular end systolic pressure decreased, the left ventricular end diastolic pressure increased, and the pressure in the right atrium (RA), RV, and pulmonary artery (PA) increased compared with the normal condition. The LVAD therapy decreased the end-systolic pressure of the LV by 41%, RA by 29%, RV by 53%, and PA by 71%, but increased the right ventricular ejection fraction by 52% and cardiac output by 40%, while the stroke work was reduced by 67% compared with the HF condition without LVAD. The end-systolic ventricular tension and strain decreased with the LVAD treatment. LVAD enhances CO and mechanical unloading of the LV as well as those of the RV and prevents pulmonary hypertension which can be induced by HF.

  16. Impact of obstructive sleep apnea and snoring on left ventricular ...

    African Journals Online (AJOL)

    Background: Systemic hypertension (HTN) and obstructive sleep apnea (OSA) are individually associated with left ventricular structural and functional adaptations. However, little is known about the impact of OSA on the left ventricle in Africans with HTN. Aim: The aim of this study is to determine the association between ...

  17. Generalised left ventricular dysfunction after traumatic right coronary ...

    African Journals Online (AJOL)

    A patient with traumatic right coronary artery to right atrial fistula, which was repaired by direct closure and aortocoronary saphenous vein bypass grafting, is described. Cardiac catheterisation and selective cine angiocardiography were performed pre- and postoperatively, and left ventricular (LV) function was studied in ...

  18. A modified Glenn shunt reduces right ventricular stroke work during left ventricular assist device therapy.

    Science.gov (United States)

    Schiller, Petter; Vikholm, Per; Hellgren, Laila

    2016-03-01

    Right ventricular (RV) failure is a major cause of morbidity and mortality after left ventricular assist device (LVAD) placement and remains hard to predict. We hypothesized that partial surgical exclusion of the RV with a modified Glenn shunt during LVAD treatment would reduce RV stroke work. An LVAD was implanted in eight pigs and a modified Glenn shunt was constructed. A conductance pressure-volume catheter was placed in the right ventricle through the apex. Haemodynamic data and pressure-volume loops were obtained at the following time periods: (i) baseline, (ii) open shunt, (iii) LVAD with closed shunt and (iii) LVAD and open shunt. During LVAD therapy, the right atrial (RA) pressure increased from 9 mmHg (9-9) to 15 mmHg (12-15), P = 0.01. RV stroke volume increased from 30 ml (29-40) to 51 ml (42-53), P work increased to 708 mmHg ml (654-1193) from 535 mmHg ml (424-717), P = 0.04, compared with baseline. During LVAD therapy in combination with a Glenn shunt, the RA pressure decreased from 15 mmHg (12-15) to 10 mmHg (7-11) when compared with LVAD therapy only, P = 0.01. A decrease in RV stroke work from 708 mmHg ml (654-1193) to 465 mmHg ml (366-711), P = 0.04, was seen when the LVAD was combined with a shunt, not significantly different from the baseline value (535 mmHg ml). The developed pressure in the right ventricle decreased from 29 mmHg (26-32) to 21 mmHg (20-24), P work during the use of the shunt with LVAD treatment. A modified Glenn shunt reduced RV volumes, RV stroke work and RA pressure during LVAD therapy in an experimental model of heart failure in pigs. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  19. Effects of sedation on echocardiographic variables of left atrial and left ventricular function in healthy cats.

    Science.gov (United States)

    Ward, Jessica L; Schober, Karsten E; Fuentes, Virginia Luis; Bonagura, John D

    2012-10-01

    Although sedation is frequently used to facilitate patient compliance in feline echocardiography, the effects of sedative drugs on echocardiographic variables have been poorly documented. This study investigated the effects of two sedation protocols on echocardiographic indices in healthy cats, with special emphasis on the assessment of left atrial size and function, as well as left ventricular diastolic performance. Seven cats underwent echocardiography (transthoracic two-dimensional, spectral Doppler, color flow Doppler and tissue Doppler imaging) before and after sedation with both acepromazine (0.1 mg/kg IM) and butorphanol (0.25 mg/kg IM), or acepromazine (0.1 mg/kg IM), butorphanol (0.25 mg/kg IM) and ketamine (1.5 mg/kg IV). Heart rate increased significantly following acepromazine/butorphanol/ketamine (mean±SD of increase, 40±26 beats/min) and non-invasive systolic blood pressure decreased significantly following acepromazine/butorphanol (mean±SD of decrease, 12±19 mmHg). The majority of echocardiographic variables were not significantly different after sedation compared with baseline values. Both sedation protocols resulted in mildly decreased left ventricular end-diastolic dimension and mildly increased left ventricular end-diastolic wall thickness. This study therefore failed to demonstrate clinically meaningful effects of these sedation protocols on echocardiographic measurements, suggesting that sedation with acepromazine, butorphanol and/or ketamine can be used to facilitate echocardiography in healthy cats.

  20. The impact of preload reduction with head-up tilt testing on longitudinal and transverse left ventricular mechanics.

    Science.gov (United States)

    Schneider, Caroline; Forsythe, Lynsey; Somauroo, John; George, Keith; Oxborough, David

    2018-01-03

    Left ventricular (LV) function is dependent on load, intrinsic contractility and relaxation with a variable impact on specific mechanics. Strain (ε) imaging allows the assessment of cardiac function however the direct relationship between volume and strain is currently unknown. The aim of this study was to establish the impact of preload reduction through head-up tilt (HUT) testing on simultaneous left ventricular (LV) longitudinal and transverse function and their respective contribution to volume change. A focused transthoracic echocardiogram was performed on 10 healthy male participants (23 ± 3 years,) in the supine position and following 1 min and 5 min of HUT testing. Raw temporal longitudinal ε (Ls) and transverse ε (Ts) values were exported and divided into 5% increments across the cardiac cycle and corresponding LV volumes were traced at each 5% increment. This provided simultaneous LV longitudinal and transverse ε and volume-loops (deformation-volume analysis - DVA). There was a leftward- shift of the ε -volume loop from supine to 1 min and 5 min of HUT, ptransverse thickening from supine to 1min, which was further augmented at 5min (p=0.018). Preload reduction occurs within 1 minute of HUT but does not further reduce at 5 minutes. This decline is associated with a decrease in longitudinal ε and concomitant increase in transverse ε. Consequently, augmented transverse relaxation appears to be an important factor in the maintenance of LV filling in the setting of reduced preload. DVA provides information on the relative contribution of mechanics to a change in LV volume and may have a role in the assessment of clinical populations. © 2018 The authors.

  1. Durability of central aortic valve closure in patients with continuous flow left ventricular assist devices.

    Science.gov (United States)

    McKellar, Stephen H; Deo, Salil; Daly, Richard C; Durham, Lucian A; Joyce, Lyle D; Stulak, John M; Park, Soon J

    2014-01-01

    A competent aortic valve is essential to providing effective left ventricular assist device support. We have adopted a practice of central aortic valve closure by placing a simple coaptation stitch at left ventricular assist device implantation in patients with significant aortic insufficiency. We conducted a follow-up study to evaluate the efficacy and durability of this procedure. The study included patients who had undergone continuous flow left ventricular assist device implantation. The patients were divided into 2 groups, those who did not require any aortic procedure because the valve was competent and those who underwent central aortic valve closure for mild or greater aortic regurgitation. The clinical endpoints were mortality, progression or recurrence of aortic insufficiency, and reoperation for aortic valve pathologic features. Aortic insufficiency was measured qualitatively from mild to severe on a scale of 0 to 5. A total of 123 patients received continuous flow left ventricular assist devices from February 2007 to August 2011. Of those, 18 (15%) underwent central aortic valve closure at left ventricular assist device implantation because of significant aortic insufficiency (1.8 ± 1.4) and 105 who did not (competent aortic valve, 0.15 ± 0.43; P assist device-supported patients, with follow-up extending into 2 years. Although aortic insufficiency progressed over time in those with minimal native valve regurgitation initially, no such progression was noted in those with central aortic valve closure. Additional investigation is needed to evaluate whether prophylactic central aortic valve closure should be performed at left ventricular assist device implantation to avoid problematic aortic regurgitation developing over time, in particular in patients undergoing left ventricular assist device implantation for life-long (destination therapy) support. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights

  2. The thick left ventricular wall of the giraffe heart normalises wall tension, but limits stroke volume and cardiac output

    DEFF Research Database (Denmark)

    Smerup, Morten Holdgaard; Damkjær, Mads; Brøndum, Emil

    2016-01-01

    Giraffes - the tallest extant animals on Earth - are renowned for their high central arterial blood pressure, which is necessary to secure brain perfusion. The pressure which may exceed 300 mmHg has historically been attributed to an exceptionally large heart. Recently, this has been refuted...... by several studies demonstrating that the mass of giraffe heart is similar to that of other mammals when expressed relative to body mass. It remains enigmatic, however, how the normal-sized giraffe heart generates such massive arterial pressures.We hypothesized that giraffe hearts have a small...... intraventricular cavity and a relatively thick ventricular wall, allowing for generation of high arterial pressures at normal left ventricular wall tension. In nine anaesthetized giraffes (495±38 kg), we determined in vivo ventricular dimensions using echocardiography along with intraventricular and aortic...

  3. Congenital bicuspid stenosis with left ventricular hypoplasia in a kitten.

    Science.gov (United States)

    van Nie, C J; van Messel, M A; Straatman, T J

    1980-01-15

    Congenital bicuspid stenosis with left ventricular hypoplasia was diagnosed in a kitten. Clinical weakness, dyspnoea and marked cardiomegaly (X rays) were related to postmortem findings. The cardiomegaly had resulted from an enlargement of the left auricular appendage. It is supposed the cardiomegaly developed after the closing of the foramen ovale.

  4. Assessment of left ventricular performance by ECG-gated SPECT. Comparison with magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Tadamura, Eiji; Inubushi, Masayuki; Kubo, Shigeto; Matsumoto, Keiichi; Yokoyama, Hiroshi; Fujita, Toru; Konishi, Junji [Kyoto Univ. (Japan). Faculty of Medicine

    1999-10-01

    In the measurement of a left ventricular volume, MIBI-QGS was compared with MRI. Because it became clear by the experiment using phantom that a volume calculated with QGS was smaller than the actual volume, data of clinical study were corrected. Subjects were 20 patients with coronary artery disease. Fourteen patients had anamnesis of myocardial infarct. ECG-gated SPECT was performed one hour after intravenous injection of MIBI (600 MBq) in rest. End diastolic volume (EDV), end systolic volume (ESV) and ejection fraction (EF) were calculated using QGS. Cine-MR image was obtained by using MR system of 1.5 Tesla within 1 week after SPECT. A condition was as follows; segmented k-space gradient echo with view sharing, TR=11 ms, TE=1.4 ms, flip angle 20 degree, field of view 32 cm, matrix 256 x 196, 8 lines per segment. LVEF, ESV and EF were analysed by Bland-Altman method, and the difference between MIBI-gated-SPECT and MRI was no problem. Horizontal dislocation image and vertical major axis dislocation image were provided. Minor axis crossing images of 10-12 slice were also filmed in order to cover all left ventricles. As a result, availability of MIBI-QGS became clear. Some factors which produces the measurement error are examined. (K.H.)

  5. The effects of stress on left ventricular ejection fraction

    International Nuclear Information System (INIS)

    Kiess, M.C.; Dimsdale, J.E.; Moore, R.H.; Liu, P.; Newell, J.; Barlai-Kovach, M.; Boucher, C.A.; Strauss, H.W.; Massachusetts General Hospital, Boston; Massachusetts General Hospital, Boston

    1988-01-01

    The left ventricular ejection fraction (EF) was studied in 17 healthy volunteers with a new ambulatory left ventricular function monitor. Heart rate, EF, and blood pressure measurements were made during rest, a psychiatric stress interview, cold exposure, exercise, and eating. An increase in EF was seen during emotional stress (from 0.45±0.09 to 0.51±0.13, P<0.001). This increase was comparable to that observed during exercise (0.52±0.14) and eating (0.52±0.10, P<0.001). In contrast, cold exposure caused a decrease in EF (0.43±0.13, P<0.05). These observations demonstrate the powerful hemodynamic consequences of common behaviors as well as the utility and feasability of studying such behavioral factors in ambulatory subjects. (orig.)

  6. Feasibility of free-breathing, GRAPPA-based, real-time cardiac cine assessment of left-ventricular function in cardiovascular patients at 3T.

    Science.gov (United States)

    Zhu, Xiaomei; Schwab, Felix; Marcus, Roy; Hetterich, Holger; Theisen, Daniel; Kramer, Harald; Notohamiprodjo, Mike; Schlett, Christopher L; Nikolaou, Konstantin; Reiser, Maximilian F; Bamberg, Fabian

    2015-05-01

    To determine the feasibility of free-breathing, GRAPPA-based, real-time (RT) cine 3T cardiac magnetic resonance imaging (MRI) with high acceleration factors for the assessment of left-ventricular function in a cohort of patients as compared to conventional segmented cine imaging. In this prospective cohort study, subjects with various cardiac conditions underwent MRI involving two RT cine sequences (high resolution and low resolution) and standard segmented cine imaging. Standard qualitative and quantitative parameters of left-ventricular function were quantified. Among 25 subjects, 24 were included in the analysis (mean age: 50.5±21 years, 67% male, 25% with cardiomyopathy). RT cine derived quantitative parameters of volumes and left ventricular mass were strongly correlated with segmented cine imaging (intraclass correlation coefficient [ICC]: >0.72 for both RT cines) but correlation for peak ejection and filling rates were moderate to poor for both RT cines (ICCcines significantly underestimated peak ejection and filling rates (>103.2±178 ml/s). Among patient-related factors, heart rate was strongly predictive for deviation of measurements (pcine MRI at 3T is feasible for qualitative and quantitative assessment of left ventricular function for low and high-resolution sequences but results in significant underestimation of systolic function, peak ejection and filling rates. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  7. Accuracy of diagnosis of coronary artery disease by radionuclide management of left ventricular function during rest and exercise

    International Nuclear Information System (INIS)

    Jones, R.H.; McEwan, P.; Newman, G.E.; Port, S.; Rerych, S.K.; Scholz, P.M.; Upton, M.T.; Peter, C.A.; Austin, E.H.; Leong, K.H.; Gibbons, R.J.; Cobb, F.R.; Coleman, R.E.; Sabiston, D.C. Jr.

    1981-01-01

    Rest and exercise radionuclide angiocardiographic measurements of left ventricular function were obtained in 496 patients who underwent cardiac catheterization for chest pain. Two hundred forty-eight of these patients also had an exercise treadmill test. An ejection fraction less than 50% was the abnormality of resting left ventricular function that provided the greatest diagnostic information. In patients with normal resting left ventricular function, exercise abnormalities that were optimal for diagnosis of coronary artery disease were an injection fraction at least 6% less than predicted, an increase greater than 20 ml in end-systolic volume and the appearance of an exercise-induced wall motion abnormality. The sensitivity and specificity of the test were lower in patients who were taking propranolol at the time of study and in patients who failed to achieve an adequate exercise end point. In the 387 patients with an optimal study, the test had a sensitivity of 90% and a specificity of 58%. Radionuclide angiocardiography was more sensitive and less specific than the exercise treadmill test. The high degree of sensitivity of the radionuclide test suggests that it is most appropriately applied to patient groups with a high prevalence of disease, including those considered for cardiac catheterization

  8. Cardiothoracic ratio for prediction of left ventricular dilation: a systematic review and pooled analysis.

    Science.gov (United States)

    Loomba, Rohit S; Shah, Parinda H; Nijhawan, Karan; Aggarwal, Saurabh; Arora, Rohit

    2015-03-01

    Increased cardiothoracic ratio noted on chest radiographs often prompts concern and further evaluation with additional imaging. This study pools available data assessing the utility of cardiothoracic ratio in predicting left ventricular dilation. A systematic review of the literature was conducted to identify studies comparing cardiothoracic ratio by chest x-ray to left ventricular dilation by echocardiography. Electronic databases were used to identify studies which were then assessed for quality and bias, with those with adequate quality and minimal bias ultimately being included in the pooled analysis. The pooled data were used to determine the sensitivity, specificity, positive predictive value and negative predictive value of cardiomegaly in predicting left ventricular dilation. A total of six studies consisting of 466 patients were included in this analysis. Cardiothoracic ratio had 83.3% sensitivity, 45.4% specificity, 43.5% positive predictive value and 82.7% negative predictive value. When a secondary analysis was conducted with a pediatric study excluded, a total of five studies consisting of 371 patients were included. Cardiothoracic ratio had 86.2% sensitivity, 25.2% specificity, 42.5% positive predictive value and 74.0% negative predictive value. Cardiothoracic ratio as determined by chest radiograph is sensitive but not specific for identifying left ventricular dilation. Cardiothoracic ratio also has a strong negative predictive value for identifying left ventricular dilation.

  9. Feasibility of free-breathing, GRAPPA-based, real-time cardiac cine assessment of left-ventricular function in cardiovascular patients at 3 T

    International Nuclear Information System (INIS)

    Zhu, Xiaomei; Schwab, Felix; Marcus, Roy; Hetterich, Holger; Theisen, Daniel; Kramer, Harald; Notohamiprodjo, Mike; Schlett, Christopher L.; Nikolaou, Konstantin; Reiser, Maximilian F.

    2015-01-01

    Highlights: • Grappa-based real time cine cardiac MRI is feasible for assessment of left ventricular function. • Significant underestimation of systolic function, peak ejection and filling rates needs to be considered. • Heart rate is the only positive predictor of the deviation of obtained parameters. - Abstract: Objectives: To determine the feasibility of free-breathing, GRAPPA-based, real-time (RT) cine 3 T cardiac magnetic resonance imaging (MRI) with high acceleration factors for the assessment of left-ventricular function in a cohort of patients as compared to conventional segmented cine imaging. Materials and methods: In this prospective cohort study, subjects with various cardiac conditions underwent MRI involving two RT cine sequences (high resolution and low resolution) and standard segmented cine imaging. Standard qualitative and quantitative parameters of left-ventricular function were quantified. Results: Among 25 subjects, 24 were included in the analysis (mean age: 50.5 ± 21 years, 67% male, 25% with cardiomyopathy). RT cine derived quantitative parameters of volumes and left ventricular mass were strongly correlated with segmented cine imaging (intraclass correlation coefficient [ICC]: >0.72 for both RT cines) but correlation for peak ejection and filling rates were moderate to poor for both RT cines (ICC < 0.40). Similarly, RT cines significantly underestimated peak ejection and filling rates (>103.2 ± 178 ml/s). Among patient-related factors, heart rate was strongly predictive for deviation of measurements (p < 0.05). Conclusions: RT cine MRI at 3 T is feasible for qualitative and quantitative assessment of left ventricular function for low and high-resolution sequences but results in significant underestimation of systolic function, peak ejection and filling rates

  10. Perioperative management of calves undergoing implantation of a left ventricular assist device.

    Science.gov (United States)

    Wilson, D V; Kantrowitz, A; Pacholewicz, J; Salat, O; Paules, B R; Zhou, Y; Dawe, E J

    2000-01-01

    To describe perioperative management of calves that underwent left lateral thoracotomy, aortic cross-clamping, partial left heart bypass and implantation of a left ventricular assist device. A total of 43 healthy castrated male calves, weighing 121 +/- 24 kg. Diazepam (mean +/- SD, 0.26 +/- 0.07 mg/kg), ketamine (5.9 +/- 2.17 mg/kg) and isoflurane were used in the anesthetic management of calves undergoing implantation of a left ventricular assist device in the descending thoracic aorta. Other adjunctive agents administered were fentanyl (11 +/- 5.4 microg/kg), lidocaine (4.9 +/- 3.19 mg/kg), bupivacaine (0.75%) and butorphanol (0.49 +/- 0.13 mg/kg). None of the calves regurgitated at induction or during intubation. A tube was used to drain the rumen and prevent bloat during the procedure. Partial left heart bypass was used to perfuse the caudal half of the body during the period of aortic cross clamp and device implantation. Initial mean systemic blood pressure was 96 +/- 25 mm Hg, and pressures measured in the auricular artery increased during aortic cross-clamping and bypass. Vasoconstrictor therapy was required to treat caudal arterial hypotension during the procedure in 9 calves. Mean systemic arterial pressures returned to baseline values by the end of the anesthetic period. Initial mean pulmonary arterial pressures (PAP) were 22 +/- 3 mm Hg. A significant but transient increase in pulmonary arterial pressure occurred after both heparin and protamine administration. The described anesthetic protocol was effective for thoracotomy and implantation of an intra-aortic left ventricular assist device in normal calves. Partial left ventricular bypass was a useful adjunct during the period of aortic cross clamp. The doses of heparin and protamine administered were effective. Responsibility to monitor oxygenation of the cranial half of the animal continues during the bypass period as hypoxemia due to pulmonary dysfunction will not be detected by the perfusionist.

  11. Evaluation of the influence of change in heart rate on left ventricular diastolic function indices

    International Nuclear Information System (INIS)

    Kimura, Motomasa; Yamagishi, Hiroaki; Seino, Yasuyuki; Odano, Ikuo; Sakai, Kunio; Yamamoto, Tomohiko; Tsuda, Takashi

    1988-01-01

    In order to assess the influence of change in heart rate on left ventricular diastolic function indices, ECG gated cardiac pool study was performed in 6 patients with implanted programmable AAI pacemakers. Heart rate was changed by atrial pacing from 50 to 120 beats/min, every 10 beats/min. The filling fraction during first third of diastole (1/3FF), the peak filling rate (PFR), mean first third filling rate (1/3FR-mean) and early filling volume ratio (%EFV), being used as the indices of left ventricular diastolic performance, were assessed. In accordance with increase in heart rate, 1/3FF decreased significantly. PFR were fairly stable from 50 to 80 beats/min, but increased significantly from 90 to 120 beats/min. 1/3FR-mean and %EFV did not change significantly, but 1/3FR-mean showed decreasing tendency and %EFV showed increasing tendency as the heart rate was increased. %EFV was more changeable index than other indices among clinical cases. These results indicate that PFR and 1/3FR-mean were appropriate diastolic phase indices at rest. (author)

  12. Automatic localization of the left ventricular blood pool centroid in short axis cardiac cine MR images.

    Science.gov (United States)

    Tan, Li Kuo; Liew, Yih Miin; Lim, Einly; Abdul Aziz, Yang Faridah; Chee, Kok Han; McLaughlin, Robert A

    2018-06-01

    In this paper, we develop and validate an open source, fully automatic algorithm to localize the left ventricular (LV) blood pool centroid in short axis cardiac cine MR images, enabling follow-on automated LV segmentation algorithms. The algorithm comprises four steps: (i) quantify motion to determine an initial region of interest surrounding the heart, (ii) identify potential 2D objects of interest using an intensity-based segmentation, (iii) assess contraction/expansion, circularity, and proximity to lung tissue to score all objects of interest in terms of their likelihood of constituting part of the LV, and (iv) aggregate the objects into connected groups and construct the final LV blood pool volume and centroid. This algorithm was tested against 1140 datasets from the Kaggle Second Annual Data Science Bowl, as well as 45 datasets from the STACOM 2009 Cardiac MR Left Ventricle Segmentation Challenge. Correct LV localization was confirmed in 97.3% of the datasets. The mean absolute error between the gold standard and localization centroids was 2.8 to 4.7 mm, or 12 to 22% of the average endocardial radius. Graphical abstract Fully automated localization of the left ventricular blood pool in short axis cardiac cine MR images.

  13. Left ventricular twist is load-dependent as shown in a large animal model with controlled cardiac load

    Directory of Open Access Journals (Sweden)

    A’roch Roman

    2012-06-01

    Full Text Available Abstract Background Left ventricular rotation and twist can be assessed noninvasively by speckle tracking echocardiography. We sought to characterize the effects of acute load change and change in inotropic state on rotation parameters as a measure of left ventricular (LV contractility. Methods Seven anesthetised juvenile pigs were studied, using direct measurement of left ventricular pressure and volume and simultaneous transthoracic echocardiography. Transient inflation of an inferior vena cava balloon (IVCB catheter produced controlled load reduction. First and last beats in the sequence of eight were analysed with speckle tracking (STE during the load alteration and analysed for change in rotation/twist during controlled load alteration at same contractile status. Two pharmacological inotropic interventions were also included to examine the same hypothesis in additionally conditions of increased and decreased myocardial contractility in each animal. Paired comparisons were made for different load states using the Wilcoxon’s Signed Rank test. Results The inferior vena cava balloon occlusion (IVCBO load change compared for first to last beat resulted in LV twist increase (11.67° ±2.65° vs. 16.17° ±3.56° respectively, p  Conclusions Peak systolic LV twist and peak early diastolic untwisting rate are load dependent. Differences in LV load should be included in the interpretation when serial measures of twist are compared.

  14. Quantitative Assessment of Left Ventricular Function and Myocardial Mass: A Comparison of Coronary CT Angiography with Cardiac MRI and Echocardiography

    International Nuclear Information System (INIS)

    Kara, Bedia; Nayman, Alaaddin; Guler, Ibrahim; Gul, Enes Elvin; Koplay, Mustafa; Paksoy, Yahya

    2016-01-01

    The purpose of this study was to compare the left ventricular parameters obtained from multi-detector row computed tomography (MDCT) studies with two-dimensional echocardiography (2DE), and magnetic resonance imaging (MRI), which is accepted as the gold standard in the evaluation of left ventricular functions. The study also aimed to evaluate whether or not there is a relationship between the MR-Argus and CMR tools software programs which are used in post-process calculations of data obtained by MRI. Forty patients with an average age of 51.4±14.9 years who had been scanned with cardiac MDCT were evaluated with cardiac MRI and 2DE. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), cardiac output (CO), and myocardial mass values calculated by MDCT, MRI, and 2DE were compared with each other. Two different MR software programs were used to compare left ventricular functions. The CMR tools LV tutorials method is accepted as the gold standard because it can be used in three-dimensional functional evaluation. The Pearson Correlation and Bland-Altman analysis were performed to compare the results from the two MR methods (MR-Argus and CMR tools) and the results from both the MDCT and the 2DE with the CMR tools results. Strong positive correlations for EF values were found between the MDCT and CMR tools (r=0.702 p<0.001), and between the MR-Argus and CMR tools (r=0.746 p<0.001). The correlation between the 2DE and CMR tools (r=0.449 p<0.004), however, was only moderate. Similar results were obtained for the other parameters. The strongest correlation for ESV, EDV, and EF was between the two MR software programs. The correlation coefficient between the MDCT and CMR tools is close to the correlation coefficient between the two software programs. While the correlation between 2DE and CMR tools was satisfactory for ESV, EDV, and CO values, it was at a moderate level for the other parameters. Left ventricular functional analysis

  15. Ebstein’s Anomaly, Left Ventricular Noncompaction, and Sudden Cardiac Death

    Directory of Open Access Journals (Sweden)

    Michael McGee

    2015-01-01

    Full Text Available Ebstein’s anomaly is a congenital disorder characterized by apical displacement of the septal leaflet of the tricuspid valve. Ebstein’s anomaly may be seen in association with other cardiac conditions, including patent foramen ovale, atrial septal defect, and left ventricular noncompaction (LVNC. LVNC is characterized by increased trabeculation within the left ventricular apex. Echocardiography is often used to diagnose LVNC; however, magnetic resonance (MR imaging offers superior characterization of the myocardium. We report a case of sudden cardiac death in a patient with Ebstein’s anomaly with unrecognized LVNC noted on post mortem examination with screening documenting the presence of LVNC in one of the patient’s twin sons.

  16. Left ventricular hypertrophy among chronic kidney disease patients ...

    African Journals Online (AJOL)

    Introduction: The presence of left ventricular hypertrophy (LVH) in patients with Chronic Kidney Disease (CKD) is associated with worsening cardiovascular outcomes. There is a dearth of data on LVH in Ghanaian CKD patients. Methods: This was a cross sectional study carried out at the Komfo Anokye Teaching Hospital ...

  17. Systolic and Diastolic Left Ventricular Mechanics during and after Resistance Exercise.

    Science.gov (United States)

    Stöhr, Eric J; Stembridge, Mike; Shave, Rob; Samuel, T Jake; Stone, Keeron; Esformes, Joseph I

    2017-10-01

    To improve the current understanding of the impact of resistance exercise on the heart, by examining the acute responses of left ventricular (LV) strain, twist, and untwisting rate ("LV mechanics"). LV echocardiographic images were recorded in systole and diastole before, during and immediately after (7-12 s) double-leg press exercise at two intensities (30% and 60% of maximum strength, one-repetition maximum). Speckle tracking analysis generated LV strain, twist, and untwisting rate data. Additionally, beat-by-beat blood pressure was recorded and systemic vascular resistance (SVR) and LV wall stress were calculated. Responses in both exercise trials were statistically similar (P > 0.05). During effort, stroke volume decreased, whereas SVR and LV wall stress increased (P mechanics (P 0.05). Immediately after exercise, systolic LV mechanics returned to baseline levels (P mechanics, but increases diastolic mechanics after exercise, suggesting that resistance exercise has a differential impact on systolic and diastolic heart muscle function. The findings may explain why acute resistance exercise has been associated with reduced stroke volume but chronic exercise training may result in increased LV volumes.

  18. Left ventricular mechanical adaptation to chronic aortic regurgitation in intact dogs

    International Nuclear Information System (INIS)

    Florenzano, F.; Glantz, S.A.

    1987-01-01

    Increased and end-diastolic wall stress has been hypothesized to stimulate left ventricular (LV) hypertrophy following volume overload. The authors instrumented intact-chest dogs with radiopaque markers in both ventricles and created volume overload by puncturing one aortic valve cusp. An x-ray system with biplane fluoroscopic and cineradiographic capabilities was used. End-diastolic stress increased immediately, then fell over 3 mo as the heart hypertrophied. End-systolic stress did not change significantly. Chamber contractility, quantified as E/sub max/, the end-systolic pressure-volume line slope, increased. E/sub max/ normalized by multiplying by LV mass increased following the lesion before but not after β-blockade with propranolol and did not change significantly over time, suggesting that chamber contractility changed because of increased mass and sympathetic tone rather than changed intrinsic muscle function. LV mass did not initially correlate with lesion size, but steady-state mass did. Over the range of lesions the authors produced, increased end-diastolic wall stress appears to stimulate hypertrophy at a fixed rate, which stops when end-diastolic wall stress has been reduced to an acceptable level

  19. Sudden death in patients with myocardial infarction and left ventricular dysfunction, heart failure, or both

    DEFF Research Database (Denmark)

    Solomon, Scott D; Zelenkofske, Steve; McMurray, John J V

    2005-01-01

    BACKGROUND: The risk of sudden death from cardiac causes is increased among survivors of acute myocardial infarction with reduced left ventricular systolic function. We assessed the risk and time course of sudden death in high-risk patients after myocardial infarction. METHODS: We studied 14......,609 patients with left ventricular dysfunction, heart failure, or both after myocardial infarction to assess the incidence and timing of sudden unexpected death or cardiac arrest with resuscitation in relation to the left ventricular ejection fraction. RESULTS: Of 14,609 patients, 1067 (7 percent) had an event...... percent confidence interval, 0.11 to 0.18 percent) after 2 years. Patients with a left ventricular ejection fraction of 30 percent or less were at highest risk in this early period (rate, 2.3 percent per month; 95 percent confidence interval, 1.8 to 2.8 percent). Nineteen percent of all sudden deaths...

  20. Importance of Non-invasive Right and Left Ventricular Variables on Exercise Capacity in Patients with Tetralogy of Fallot Hemodynamics.

    Science.gov (United States)

    Meierhofer, Christian; Tavakkoli, Timon; Kühn, Andreas; Ulm, Kurt; Hager, Alfred; Müller, Jan; Martinoff, Stefan; Ewert, Peter; Stern, Heiko

    2017-12-01

    Good quality of life correlates with a good exercise capacity in daily life in patients with tetralogy of Fallot (ToF). Patients after correction of ToF usually develop residual defects such as pulmonary regurgitation or stenosis of variable severity. However, the importance of different hemodynamic parameters and their impact on exercise capacity is unclear. We investigated several hemodynamic parameters measured by cardiovascular magnetic resonance (CMR) and echocardiography and evaluated which parameter has the most pronounced effect on maximal exercise capacity determined by cardiopulmonary exercise testing (CPET). 132 patients with ToF-like hemodynamics were tested during routine follow-up with CMR, echocardiography and CPET. Right and left ventricular volume data, ventricular ejection fraction and pulmonary regurgitation were evaluated by CMR. Echocardiographic pressure gradients in the right ventricular outflow tract and through the tricuspid valve were measured. All data were classified and correlated with the results of CPET evaluations of these patients. The analysis was performed using the Random Forest model. In this way, we calculated the importance of the different hemodynamic variables related to the maximal oxygen uptake in CPET (VO 2 %predicted). Right ventricular pressure showed the most important influence on maximal oxygen uptake, whereas pulmonary regurgitation and right ventricular enddiastolic volume were not important hemodynamic variables to predict maximal oxygen uptake in CPET. Maximal exercise capacity was only very weakly influenced by right ventricular enddiastolic volume and not at all by pulmonary regurgitation in patients with ToF. The variable with the most pronounced influence was the right ventricular pressure.

  1. Desmin loss and mitochondrial damage precede left ventricular systolic failure in volume overload heart failure.

    Science.gov (United States)

    Guichard, Jason L; Rogowski, Michael; Agnetti, Giulio; Fu, Lianwu; Powell, Pamela; Wei, Chih-Chang; Collawn, James; Dell'Italia, Louis J

    2017-07-01

    Heart failure due to chronic volume overload (VO) in rats and humans is characterized by disorganization of the cardiomyocyte desmin/mitochondrial network. Here, we tested the hypothesis that desmin breakdown is an early and continuous process throughout VO. Male Sprague-Dawley rats had aortocaval fistula (ACF) or sham surgery and were examined 24 h and 4 and 12 wk later. Desmin/mitochondrial ultrastructure was examined by transmission electron microscopy (TEM) and immunohistochemistry (IHC). Protein and kinome analysis were performed in isolated cardiomyocytes, and desmin cleavage was assessed by mass spectrometry in left ventricular (LV) tissue. Echocardiography demonstrated a 40% decrease in the LV mass-to-volume ratio with spherical remodeling at 4 wk with ACF and LV systolic dysfunction at 12 wk. Starting at 24 h and continuing to 4 and 12 wk, with ACF there is TEM evidence of extensive mitochondrial clustering, IHC evidence of disorganization associated with desmin breakdown, and desmin protein cleavage verified by Western blot analysis and mass spectrometry. IHC results revealed that ACF cardiomyocytes at 4 and 12 wk had perinuclear translocation of αB-crystallin from the Z disk with increased α, β-unsaturated aldehyde 4-hydroxynonelal. Use of protein markers with verification by TUNEL staining and kinome analysis revealed an absence of cardiomyocyte apoptosis at 4 and 12 wk of ACF. Significant increases in protein indicators of mitophagy were countered by a sixfold increase in p62/sequestosome-1, which is indicative of an inability to complete autophagy. An early and continuous disruption of the desmin/mitochondrial architecture, accompanied by oxidative stress and inhibition of apoptosis and mitophagy, suggests its causal role in LV dilatation and systolic dysfunction in VO. NEW & NOTEWORTHY This study provides new evidence of early onset (24 h) and continuous (4-12 wk) desmin misarrangement and disruption of the normal sarcomeric and mitochondrial

  2. Risk factors and predictors of Torsade de pointes ventricular tachycardia in patients with left ventricular systolic dysfunction receiving Dofetilide

    DEFF Research Database (Denmark)

    Pedersen, Henriette Sloth; Elming, Hanne; Seibaek, Marie

    2007-01-01

    The purpose of this study was to identify risk factors of Torsade de pointes (TdP) ventricular tachycardia in patients medicated with a class III antiarrhythmic drug (dofetilide) and left ventricular systolic dysfunction with heart failure (HF) or recent myocardial infarction (MI). The 2 Danish...

  3. Regression in left ventricular mass after aortic valve replacement for chronic aortic regurgitation is unrelated to prosthetic valve size.

    Science.gov (United States)

    Brown, Morgan L; Schaff, Hartzell V; Suri, Rakesh M; Li, Zhuo; Sundt, Thoralf M; Dearani, Joseph A; Enriquez-Sarano, Maurice

    2011-08-01

    We examined the role of prosthesis-patient mismatch on left ventricular mass regression after aortic valve replacement for chronic aortic valve regurgitation. We selected patients who had complete preoperative and follow-up echocardiograms with measurement of left ventricular mass. Patients were excluded who had moderate or greater aortic valve stenosis, concomitant coronary artery bypass grafting, or mitral valve procedures. Patients' mean age was 55 ± 17 years; 21% were female. The mean preoperative indexed left ventricular mass was 150 ± 45 g/m(2). Patients with mildly (n = 44; mean indexed mass, 126 ± 15 g/m(2)), moderately (n = 31; mean indexed mass, 168 ± 11 g/m(2)), or severely (n = 15; mean indexed mass, 241 ± 34 g/m(2)) increased preoperative indexed left ventricular mass, were similar, except for lower ejection fractions, larger end-diastolic dimensions, and larger ventricular wall thicknesses in the severely enlarged group (P regression was unrelated to labeled valve size, prosthesis-patient mismatch, or measured indexed effective aortic valve area. A greater preoperative indexed left ventricular mass (P regression. Despite having greater left ventricular mass regression, patients with severe preoperative indexed left ventricular mass did not return to normal values (mean, 142 ± 25 g/m(2)). Left ventricular mass regression after aortic valve replacement for chronic aortic regurgitation is unrelated to indexed prosthetic valve area. Although incomplete, regression is greatest in patients with the largest preoperative indexed left ventricular mass. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  4.  Effect of Thrombolytic Therapy on the Incidence of Early Left Ventricular Infarct Expansion in Acute Anterior Myocardial Infarction

    Directory of Open Access Journals (Sweden)

    Namir Ghanim Al-Tawil

    2011-11-01

    Full Text Available  Objectives: To determine the incidence of early left ventricular infarct expansion within five days after first anterior ST-segment elevation myocardial infarction and the effect of early thrombolytic therapy on the incidence of early infarct expansion compared with late thrombolytic therapy.Methods: In a prospective study of 101 patients (75males and 26 females, with the first attack of acute anterior myocardial infarction, their ages ranged from 40-80 years (mean age: 61.07±10.78 who had been admitted to the Coronary Care Unit of Hawler Teaching Hospital for the period from July 2007 through to September 2009. Those who received alteplase ≤3 hours of acute myocardial infarction were labelled as group-I (49 patients and those who received alteplase >3-12 hours were labelled as group-II (52 patients.Results: The incidence of early left ventricular infarct expansion was diagnosed by 2D-echocardiography and was found to be 17.8�20Group I patients had a lower incidence of early left ventricular infarct expansion (8.16�20compared with group-II (26.92�20 p=0.014. Patients with early left ventricular infarct expansion had a higher frequency rate of left ventricular systolic dysfunction (94.44�20compared to patients without early left ventricular infarct expansion (8.43�20p<0.001. There was a significant difference in the incidence of in-hospital mortality between the patients who developed early left ventricular infarct expansion (11.1�20compared with patients without early left ventricular infarct expansion (1.2�20p=0.025.Conclusion: Early reperfusion therapy in acute anterior myocardial infarction can decrease the incidence of early left ventricular infarct expansion, preserve left ventricular systolic function and decrease in-hospital mortality.

  5. Management of severe ischemic cardiomyopathy: left ventricular assist device as destination therapy versus conventional bypass and mitral valve surgery.

    Science.gov (United States)

    Maltais, Simon; Tchantchaleishvili, Vahtang; Schaff, Hartzell V; Daly, Richard C; Suri, Rakesh M; Dearani, Joseph A; Topilsky, Yan; Stulak, John M; Joyce, Lyle D; Park, Soon J

    2014-04-01

    Patients with severe ischemic cardiomyopathy (left ventricular ejection fraction assist device as destination therapy is reserved for patients who are too high risk for conventional surgery. We evaluated our outcomes with conventional surgery within this population and the comparative effectiveness of these 2 therapies. We identified patients who underwent conventional surgery or left ventricular assist device as destination therapy for severe ischemic cardiomyopathy (left ventricular ejection fraction assist device as destination therapy. We compared baseline patient characteristics and outcomes in terms of end-organ function and survival. A total of 88 patients were identified; 55 patients underwent conventional surgery (63%), and 33 patients (37%) received a left ventricular assist device as destination therapy. Patients who received left ventricular assist device as destination therapy had the increased prevalence of renal failure, inotrope dependency, and intra-aortic balloon support. Patients undergoing conventional surgery required longer ventilatory support, and patients receiving a left ventricular assist device required more reoperation for bleeding. Mortality rates were similar between the 2 groups at 30 days (7% in the conventional surgery group vs 3% in the left ventricular assist device as destination therapy group, P = .65) and at 1 year (22% in the conventional surgery group vs 15% in the left ventricular assist device as destination therapy group, P = .58). There was a trend toward improved survival in patients receiving a left ventricular assist device compared with the propensity-matched groups at 1 year (94% vs 71%, P = .171). The operative mortality and early survival after conventional surgery seem to be acceptable. For inoperable or prohibitive-risk patients, left ventricular assist device as destination therapy can be offered with similar outcomes. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby

  6. Apical ballooning syndrome complicated by acute severe mitral regurgitation with left ventricular outflow obstruction – Case report

    Directory of Open Access Journals (Sweden)

    Celermajer David S

    2007-02-01

    Full Text Available Abstract Background Apical ballooning syndrome (or Takotsubo cardiomyopathy is a syndrome of transient left ventricular apical ballooning. Although first described in Japanese patients, it is now well reported in the Caucasian population. The syndrome mimicks an acute myocardial infarction but is characterised by the absence of obstructive coronary disease. We describe a serious and poorly understood complication of Takotsubo cardiomyopathy. Case Presentation We present the case of a 65 year-old lady referred to us from a rural hospital where she was treated with thrombolytic therapy for a presumed acute anterior myocardial infarction. Four hours after thrombolysis she developed acute pulmonary oedema and a new systolic murmur. It was presumed she had acute mitral regurgitation secondary to a ruptured papillary muscle, ischaemic dysfunction or an acute ventricular septal defect. Echocardiogram revealed severe mitral regurgitation, left ventricular apical ballooning, and systolic anterior motion of the mitral valve with significant left ventricular outflow tract gradient (60–70 mmHg. Coronary angiography revealed no obstructive coronary lesions. She had an intra-aortic balloon pump inserted with no improvement in her parlous haemodynamic state. We elected to replace her mitral valve to correct the outflow tract gradient and mitral regurgitation. Intra-operatively the mitral valve was mildly myxomatous but there were no structural abnormalities. She had a mechanical mitral valve replacement with a 29 mm St Jude valve. Post-operatively, her left ventricular outflow obstruction resolved and ventricular function returned to normal over the subsequent 10 days. She recovered well. Conclusion This case represents a serious and poorly understood association of Takotsubo cardiomyopathy with acute pulmonary oedema, severe mitral regurgitaton and systolic anterior motion of the mitral valve with significant left ventricular outflow tract obstruction. The

  7. Left ventricular diastolic filling in patients with systemic hypertension

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa; Honda, Minoru; Kanao, Keisuke

    1985-01-01

    To study the prevalence and significance of left ventricular (LV) diastolic dysfunction in mild to moderate systemic hypertension (HT), cardiac blood pool imagings with Tc-99 m were obtained in 10 normal subjects and 27 patients with HT. The patients with HT did not show any evidence of coronary heart disease, renal insufficiency, cerebrovascular accident or diabetes mellitus. They were divided into 3 groups; (1) HT-1 (n=10): without evidence of echocardiographic (UCG) and electrocardiographic (ECG) left ventricular hypertrophy (LVH), (2) HT-2 (n=8): with evidence of ECG-LVH without UCG-LVH, (3) HT-3 (n=9): with evidence of UCG-LVH. UCG-LVH was defined when posterior or interventricular septal tall thickness exceeded 13 mm at end-diastole. From UCG findings LV mass was calculated and from UCG findings and auscultating brachial systolic pressure LV peak-systolic wall stress (WS) was obtained. Cardiac blood pool imagings were performed at modified LAO at rest and during exercise stress. Indices of LV systolic function (rest ejection fraction, mean ejection rate during the first third of ejection and exercise ejection fraction response) were essentially similar in normal subjects and all HT groups. In contrast, LV diastolic filling rate during the first third of diastole (1/3 FR mean) decreased significantly in any group of HT, and it was prominent in HT-3. In patients with HT, 1/3 FR mean did not correlate with blood pressure, LV peak-systolic WS, LV systolic functions and LV end-diastolic volume. But it correlated inversely with LV mass (r=-0.84). These results suggest that impairment of early diastolic LV filling can be detected before systolic cardiac impairment and LVH develop, and it is, at least in part, relate to the LV mass. (author)

  8. Race differences in ventricular remodeling and function among college football players.

    Science.gov (United States)

    Haddad, Francois; Peter, Shanon; Hulme, Olivia; Liang, David; Schnittger, Ingela; Puryear, Josephine; Gomari, Fatemeh A; Finocchiaro, Gherardo; Myers, Jonathan; Froelicher, Victor; Garza, Daniel; Ashley, Euan A

    2013-07-01

    Athletic training is associated with increases in ventricular mass and volume. Recent studies have shown that left ventricular mass increases proportionally in white athletes with a mass/volume ratio approaching unity. The objective of this study was to compare the proportionality in ventricular remodeling and ventricular function in black versus white National Collegiate Athletic Association Division I football players. From 2008 to 2011, football players at Stanford University underwent cardiovascular screening with a 12-point history and physical examination, electrocardiography, and focused echocardiography. Compared with white players, black players had on average higher left ventricular mass indexes (77 ± 11 vs 71 ± 11 g/m(2), p = 0.009), higher mass/volume ratios (1.18 ± 0.16 vs 1.06 ± 0.09 g/ml, p 1.2. Mass/volume ratio was inversely related to early diastolic tissue Doppler velocity e' (r = -0.50, p football players exhibit more concentric ventricular remodeling, lower early diastolic annular velocities, and increased ventricular voltage compared with white players. Ventricular mass increases proportionally to volume in white players but not in black players. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. Left atrial strain: a new parameter for assessment of left ventricular filling pressure.

    Science.gov (United States)

    Cameli, Matteo; Mandoli, Giulia Elena; Loiacono, Ferdinando; Dini, Frank Lloyd; Henein, Michael; Mondillo, Sergio

    2016-01-01

    In order to obtain accurate diagnosis, treatment and prognostication in many cardiac conditions, there is a need for assessment of left ventricular (LV) filling pressure. While systole depends on ejection function of LV, diastole and its disturbances influence filling function and pressures. The commonest condition that represents the latter is heart failure with preserved ejection fraction in which LV ejection is maintained, but diastole is disturbed and hence filling pressures are raised. Significant diastolic dysfunction results in raised LV end-diastolic pressure, mean left atrial (LA) pressure and pulmonary capillary wedge pressure, all referred to as LV filling pressures. Left and right heart catheterization has traditionally been used as the gold standard investigation for assessing these pressures. More recently, Doppler echocardiography has taken over such application because of its noninvasive nature and for being patient friendly. A number of indices are used to achieve accurate assessment of filling pressures including: LV pulsed-wave filling velocities (E/A ratio, E wave deceleration time), pulmonary venous flow (S wave and D wave), tissue Doppler imaging (E' wave and E/E' ratio) and LA volume index. LA longitudinal strain derived from speckle tracking echocardiography (STE) is also sensitive in estimating intracavitary pressures. It is angle-independent, thus overcomes Doppler limitations and provides highly reproducible measures of LA deformation. This review examines the application of various Doppler echocardiographic techniques in assessing LV filling pressures, in particular the emerging role of STE in assessing LA pressures in various conditions, e.g., HF, arterial hypertension and atrial fibrillation.

  10. Population-specific left ventricular hypertrophy in three groups from the northeastern region of India.

    Science.gov (United States)

    Borah, P K; Hazarika, N C; Biswas, D; Kalita, H C; Mahanta, J

    2010-01-01

    People living in the hills are continuously exposed to strenuous physical activity for their day-to-day work. Besides hypertension, left ventricular hypertrophy in different populations may be related to continuous physical activity. Electrocardiogram, blood pressure and sociodemographic information of 12 252 subjects > or = 30 years of age from three different population groups living in Mizoram (hilly) and Assam (plain) were recorded. Of them, 8058 were from Mizoram and 3180 and 1014 were Indigenous Assamese and tea garden workers of Assam. Among the subjects from Mizoram the percentage of smokers (41.9%), mean (SD) BMI (21.9 [3.8]) and waist-hip ratio (0.87 [0.02]) were significantly higher than in those from other groups. Tea garden workers had a higher mean systolic blood pressure (145.2 [25.7]) and diastolic blood pressure (87.6 [13.6]). The prevalence of left ventricular hypertrophy was highest among tea garden workers (16.5%) followed by people from Mizoram (3.7%) and the indigenous Assamese (2%) people. In spite of a significantly higher prevalence of hypertension among the indigenous Assamese community than among those from Mizoram, left ventricular hypertrophy was found to be lower in the former. High prevalence of left ventricular hypertrophy among tea garden workers was possibly related to a higher prevalence of hypertension but the higher prevalence of left ventricular hypertrophy among people from Mizoram might be related to more physical activity.

  11. New digital measurement methods for left ventricular volume using real-time three-dimensional echocardiography: comparison with electromagnetic flow method and magnetic resonance imaging

    Science.gov (United States)

    Qin, J. J.; Jones, M.; Shiota, T.; Greenberg, N. L.; Firstenberg, M. S.; Tsujino, H.; Zetts, A. D.; Sun, J. P.; Cardon, L. A.; Odabashian, J. A.; hide

    2000-01-01

    AIM: The aim of this study was to investigate the feasibility and accuracy of using symmetrically rotated apical long axis planes for the determination of left ventricular (LV) volumes with real-time three-dimensional echocardiography (3DE). METHODS AND RESULTS: Real-time 3DE was performed in six sheep during 24 haemodynamic conditions with electromagnetic flow measurements (EM), and in 29 patients with magnetic resonance imaging measurements (MRI). LV volumes were calculated by Simpson's rule with five 3DE methods (i.e. apical biplane, four-plane, six-plane, nine-plane (in which the angle between each long axis plane was 90 degrees, 45 degrees, 30 degrees or 20 degrees, respectively) and standard short axis views (SAX)). Real-time 3DE correlated well with EM for LV stroke volumes in animals (r=0.68-0.95) and with MRI for absolute volumes in patients (r-values=0.93-0.98). However, agreement between MRI and apical nine-plane, six-plane, and SAX methods in patients was better than those with apical four-plane and bi-plane methods (mean difference = -15, -18, -13, vs. -31 and -48 ml for end-diastolic volume, respectively, Pmethods of real-time 3DE correlated well with reference standards for calculating LV volumes. Balancing accuracy and required time for these LV volume measurements, the apical six-plane method is recommended for clinical use.

  12. Measurement of global and regional left ventricular performance with isotope technique in coronary heart disease

    International Nuclear Information System (INIS)

    Bostroem, P.-A.; Svensson, M.; Lilja, B.

    1988-01-01

    To evaluate left ventricular function in coronary artery disease, radionuclide measurements of global and regional ejection fraction (EF), regional wall motion and phase analyses of left ventricular contraction were performed by equilibrium technique, using sup(99m)Tc. One group of patients with angina pectoris and one group with myocardial infarction were compared with a control group. All above-mentioned parameters significantly separated the infarction group from the reference group both at rest and during work, while the group of patients with angina pectoris showed disturbances mainly during work, such as impaired ability to increase global and regional ejection fraction and regional wall motion. Adding regional analysis and phase analysis to the global EF determination increases the possibility of studying the left ventricular function. However, this addition has a limited value in detecting impaired left ventricular function compared to the determination of just global EF in patients with angina pectoris and in patients with myocardial infarction. (author)

  13. COST-EFFECTIVENESS OF CONTINUOUS-FLOW LEFT VENTRICULAR ASSIST DEVICES

    NARCIS (Netherlands)

    Neyt, Mattias; Van den Bruel, Ann; Smit, Yolba; De Jonge, Nicolaas; Erasmus, Michiel; Van Dijk, Diederik; Vlayen, Joan

    Objectives: Mechanical circulatory support through left ventricular assist devices (LVADs) improves survival and quality of life for patients with end-stage heart failure who are ineligible for cardiac transplantation. Our aim was to calculate the cost-effectiveness of continuous-flow LVADs.

  14. Three-dimensional echocardiography: assessment of inter- and intra-operator variability and accuracy in the measurement of left ventricular cavity volume and myocardial mass

    International Nuclear Information System (INIS)

    Nadkarni, S.K.; Drangova, M.; Boughner, D.R.; Fenster, A.; Department of Medical Biophysics, Medical Sciences Building, University of Western Ontario, London, Ontario N6A 5C1

    2000-01-01

    Accurate left ventricular (LV) volume and mass estimation is a strong predictor of cardiovascular morbidity and mortality. We propose that our technique of 3D echocardiography provides an accurate quantification of LV volume and mass by the reconstruction of 2D images into 3D volumes, thus avoiding the need for geometric assumptions. We compared the accuracy and variability in LV volume and mass measurement using 3D echocardiography with 2D echocardiography, using in vitro studies. Six operators measured the LV volume and mass of seven porcine hearts, using both 3D and 2D techniques. Regression analysis was used to test the accuracy of results and an ANOVA test was used to compute variability in measurement. LV volume measurement accuracy was 9.8% (3D) and 18.4% (2D); LV mass measurement accuracy was 5% (3D) and 9.2% (2D). Variability in LV volume quantification with 3D echocardiography was %SEM inter = 13.5%, %SEM intra = 11.4%, and for 2D echocardiography was %SEM inter = 21.5%, %SEM intra = 19.1%. We derived an equation to predict uncertainty in measurement of LV volume and mass using 3D echocardiography, the results of which agreed with our experimental results to within 13%. 3D echocardiography provided twice the accuracy for LV volume and mass measurement and half the variability for LV volume measurement as compared with 2D echocardiography. (author)

  15. Assessment of left ventricular function using 201Tl electrocardiogram-gated myocardial single photon emission computed tomography

    International Nuclear Information System (INIS)

    Nishikubo, Naotsugu; Tamai, Hiroyuki

    2013-01-01

    Advances in computed tomography (CT) technology make it possible to obtain left ventricular wall motion using 3D reconstruction. In this study, we compared the images obtained from CT and 201 Tl electrocardiogram (ECG) gated single photon emission computed tomography (SPECT). In 20 patients with ischemic heart disease, we performed 201 Tl ECG gated SPECT (GE Healthcare Millennium VG) and ECG gated CT (Philips Medical Systems Brilliance iCT) to evaluate of left ventricular wall motion during the resting phase. In SPECT, left ventricular images were reconstructed using quantitative gated SPECT (QGS) software. In CT, the images were reconstructed using Virtual Place (AZE Software). The left ventricle was classified into five regions (anterior, lateral, inferior, septal, and apical). The amplitude of the wall motion was classified into five grades according to AHA classification. The values of the wall motion were separately checked by two radiographers. Assessment of left ventricular function myocardial wall movement using the three-dimensional movie display with ECG gated myocardial SPECT data was in agreement with the evaluation by cardiac CT inspection, and corresponded with wall motion in 88 of all 100 segments. SPECT analysis has the same quantity as that of obtained from CT for evaluation of left ventricular wall motion. (author)

  16. Adeno-associated Virus Serotype 9 - Driven Expression of BAG3 Improves Left Ventricular Function in Murine Hearts with Left Ventricular Dysfunction Secondary to a Myocardial Infarction.

    Science.gov (United States)

    Knezevic, Tijana; Myers, Valerie D; Su, Feifei; Wang, JuFang; Song, Jianliang; Zhang, Xue-Qian; Gao, Erhe; Gao, Guofeng; Muniswamy, Madesh; Gupta, Manish K; Gordon, Jennifer; Weiner, Kristen N; Rabinowitz, Joseph; Ramsey, Frederick V; Tilley, Douglas G; Khalili, Kamel; Cheung, Joseph Y; Feldman, Arthur M

    2016-12-01

    The present study was undertaken to test the hypothesis that gene delivery of BCL2-Associated Athanogene 3 (BAG3) to the heart of mice with left ventricular dysfunction secondary to a myocardial infarction could enhance cardiac performance. BAG3 is a 575 amino acid protein that has pleotropic functions in the cell including pro-autophagy and anti-apoptosis. Mutations in BAG3 have been associated with both skeletal muscle dysfunction and familial dilated cardiomyopathy and BAG3 levels are diminished in non-familial heart failure. Eight-week-old C57/BL6 mice underwent ligation of the left coronary artery (MI) or sham surgery (Sham). Eight weeks later, mice in both groups were randomly assigned to receive either a retro-orbital injection of rAAV9-BAG3 (MI-BAG3 or Sham-BAG3) or rAAV9-GFP (MI-GFP or Sham GFP). Mice were sacrificed at 3 weeks post-injection and myocytes were isolated from the left ventricle. MI-BAG3 mice demonstrated a significantly (p BAG3 injection with further improvement in LVEF, fractional shortening and stroke volume at 3 weeks post-injection without changes in LV mass or LV volume. Injection of rAAV9-BAG3 had no effect on LVEF in Sham mice. The salutary benefits of rAAV9-BAG3 were also observed in myocytes isolated from MI hearts including improved cell shortening (pBAG3 gene therapy may provide a novel therapeutic option for the treatment of heart failure.

  17. Neurohormones as markers of right- and left-sided cardiac dimensions and function in patients with untreated chronic heart failure

    DEFF Research Database (Denmark)

    Kjaer, Andreas; Hildebrandt, Per; Appel, Jon

    2005-01-01

    and that neuroendocrine profiling could be of value. In order to study this, we investigated the relationship between hormones and cardiac dimensions and function of both the right and left ventricle. METHODS: Twenty-three patients with newly diagnosed, untreated CHF were included. Right (RVEF) and left ventricular...... was normal in all subjects as well as right ventricular volumes. Likewise, on average, the lung transit time (LTT) was normal. Brain natriuretic peptide (BNP) significantly correlated with LVEF, left ventricular end-diastolic volume index (LVEDVI) and left ventricular end-systolic volume index (LVESVI...... ejection fractions (LVEF) and volumes were measured by means of first-pass and equilibrium radionuclide ventriculography. RESULTS: LVEF was 0.29 (range: 0.11-0.55). Two-thirds of the patients had dilated left ventricles with volumes above upper reference limit. Right ventricular ejection fraction...

  18. The influence of type 2 diabetes and gender on ventricular repolarization dispersion in patients with sub-clinic left ventricular diastolic dysfunction

    OpenAIRE

    Jani, Ylber; Kamberi, Ahmet; Xhunga, Sotir; Pocesta, Bekim; Ferati, Fatmir; Lala, Dali; Zeqiri, Agim; Rexhepi, Atila

    2015-01-01

    Objective: To assess the influence of type 2 DM and gender, on the QT dispersion, Tpeak-Tend dispersion of ventricular repolarization, in patients with sub-clinic left ventricular diastolic dysfunction of the heart. Background: QT dispersion, that reflects spatial inhomogeneity in ventricular repolarization, Tpeak-Tend dispersion, this on the other hand reflects transmural inhomogeneity in ventricular repolarization, that is increased in an early stage of cardiomyopathy, and in patients with ...

  19. Influence of slice thickness on the determination of left ventricular wall thickness and dimension by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ohnishi, Shusaku; Fukui, Sugao; Atsumi, Chisato and others

    1989-02-01

    Wall thickness of the ventricular septum and left ventricle, and left ventricular cavity dimension were determined on magnetic resonance (MR) images with slices 5 mm and 10 mm in thickness. Subjects were 3 healthy volunteers and 7 patients with hypertension (4), hypertrophic cardiomyopathy (one) or valvular heart disease (2). In visualizing the cardiac structures such as left ventricular papillary muscle and right and left ventricles, 5 mm-thick images were better than 10 mm-thick images. Edges of ventricular septum and left ventricular wall were more clearly visualized on 5 mm-thick images than 10 mm-thick images. Two mm-thick MR images obtained from 2 patients yielded the most excellent visualization in end-systole, but failed to reveal cardiac structures in detail in end-diastole. Phantom studies revealed no significant differences in image quality of 10 mm and 5 mm in thickness in the axial view 80 degree to the long axis. In the axial view 45 degree to the long axis, 10 mm-thick images were inferior to 5 mm-thick images in detecting the edge of the septum and the left ventricular wall. These results indicate that the selection of slice thickness is one of the most important determinant factors in the measurement of left ventricular wall thickness and cavity dimension. (Namekawa, K).

  20. Influence of slice thickness on the determination of left ventricular wall thickness and dimension by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Ohnishi, Shusaku; Fukui, Sugao; Atsumi, Chisato

    1989-01-01

    Wall thickness of the ventricular septum and left ventricle, and left ventricular cavity dimension were determined on magnetic resonance (MR) images with slices 5 mm and 10 mm in thickness. Subjects were 3 healthy volunteers and 7 patients with hypertension (4), hypertrophic cardiomyopathy (one) or valvular heart disease (2). In visualizing the cardiac structures such as left ventricular papillary muscle and right and left ventricles, 5 mm-thick images were better than 10 mm-thick images. Edges of ventricular septum and left ventricular wall were more clearly visualized on 5 mm-thick images than 10 mm-thick images. Two mm-thick MR images obtained from 2 patients yielded the most excellent visualization in end-systole, but failed to reveal cardiac structures in detail in end-diastole. Phantom studies revealed no significant differences in image quality of 10 mm and 5 mm in thickness in the axial view 80 degree to the long axis. In the axial view 45 degree to the long axis, 10 mm-thick images were inferior to 5 mm-thick images in detecting the edge of the septum and the left ventricular wall. These results indicate that the selection of slice thickness is one of the most important determinant factors in the measurement of left ventricular wall thickness and cavity dimension. (Namekawa, K)

  1. Volume ventricular esquerdo crítico na estenose aórtica no primeiro ano de vida: sua importância na seleção de pacientes candidatos à correção univentricular pós-valvotomia Critical left ventricular volume in aortic stenosis in first year of life: its importance in patients selection candidates to univentricular surgical correction pos-valvotomy

    Directory of Open Access Journals (Sweden)

    Marco Aurélio Santos

    2005-09-01

    Full Text Available OBJETIVO: Análise do volume diastólico final ventricular esquerdo crítico, definido como o menor volume aceitável para a manutenção do débito cardíaco, na seleção de pacientes com estenose aórtica pós-valvotomia, candidatos à correção univentricular. MÉTODOS: Estudo retrospectivo em 21 pacientes com estenose aórtica, durante o primeiro ano de vida, e 232 compilados da literatura. Arbitraram-se como normais os valores do volume diastólico final (VDF de 20 a 60 ml/m2. Foi comparado o VDF dos grupos que foram ao óbito com aqueles que sobreviveram. Procurou-se, também, estabelecer uma correlação da idade e volume ventricular, na época da valvotomia, entre os grupos. Por fim, determinou-se o VDF esquerdo crítico, obtido através de uma relação teórica entre o VDF esquerdo e freqüência cardíaca para diferentes frações de ejeção e determinados índices cardíacos (IC: 2.000 e 2.500 ml/min/m2. RESULTADOS: Para valores do VDF 60 ml/m2, houve significância estatística entre os mortos e os sobreviventes (pOBJECTIVE: Analysis of critical end diastolic left ventricular volume (EDLVV, defined as the lowest acceptable volume to keep cardiac output, in the selection of patients with post-valvotomy aortic stenosis, candidates to univentricular correction. METHODS: A retrospective study in 21 patients with aortic stenosis, during the first year of life, and 232 patients compiled from literature. Values of end diastolic volume (EDLVV, from 20 to 60 ml/m2 were determined as normal. The EDLVV of deceased patients was compared to that from survival patients. A correlation between the age and EDLVV was carried out at the time of valvotomy, between the groups. Finally, the critical EDLVV through the theoretical relationship between the EDLVV and heart rate for different ejection fractions and designated cardiac indexes (CI: 2,000 and 2,500 20-60 ml/min/m2 was determined. RESULTS: For EDLVV values 60 ml/m2, there was statistical

  2. Changes in Left Ventricular Diastolic Function During Hemodialysis Sessions

    NARCIS (Netherlands)

    Assa, Solmaz; Hummel, Yoran M.; Voors, Adriaan A.; Kuipers, Johanna; Groen, Henk; de Jong, Paul E.; Westerhuis, Ralf; Franssen, Casper F. M.

    Background: Left ventricular diastolic dysfunction is common in hemodialysis patients and is associated with worse outcome. Previous studies have shown that diastolic function worsens from pre- to post-dialysis session, but this has not been studied during hemodialysis. We studied the evolution of

  3. Changes of left ventricular function at exercise after lung resection; Study with a nuclear stethoscope

    Energy Technology Data Exchange (ETDEWEB)

    Fujisaki, Takashi; Gomibuchi, Makoto; Shoji, Tasuku (Nippon Medical School, Tokyo (Japan))

    1992-09-01

    To determine the effect of lung resection on left ventricular function, 29 surgical patients were examined by using a nuclear stethoscope as a non-invasive means for measuring ventricular function at exercise. Pre- and post-operative parameters were obtained at rest and exercise. At rest, postoperative stroke volume (SV), end-diastolic volume (EDV), ejection fraction (EF), and ejection rate (ER) were significantly decreased; heart rate (HR) was significantly increased; and both filling rate (FR) and cardiac output (CO) remained unchanged. At maximum exercise, postoperative EDV, SV, ER and FR were significantly decreased; and there was no significant difference in either HR or EF, resulting in a significantly decreased CO. A ratio of CO and FR at maximum exercise to at rest was significantly decreased after surgery, as compared with that before surgery. According to the number of lobe resection, similar findings for all parameters, except for EF, were observed in the group of two lobe or more resection (n=13); and only two parameters, ER and FR, had the same tendency as those mentioned above in the group of a single lobe resection (n=16). The age group of 60 years or less (n=14) had similar findings for all parameters. In the group of 65 years or more (n=10), resting HR after surgery was not different from that before surgery; and postoperative CO was significantly decreased at rest, but not different from preoperative value at maximum exercise. In conclusion, left ventricular function associated with lung resection is reflected by decreased EDV and SV resulting from reduced pre-load. These changes may be corrected at rest, but not corrected at maximum exercise, resulting in decreased CO. More noticeable decrease in EDV and SV seems to be associated with larger lung resection. In older patients, HR is not corrected well, resulting in a decrease in CO at rest. (N.K.).

  4. Age-related left ventricular remodeling and associated risk for cardiovascular outcomes: the Multi-Ethnic Study of Atherosclerosis.

    Science.gov (United States)

    Cheng, Susan; Fernandes, Verônica R S; Bluemke, David A; McClelland, Robyn L; Kronmal, Richard A; Lima, João A C

    2009-05-01

    Age-related alterations of left ventricular (LV) structure and function that may predispose to cardiovascular events are not well understood. We used cardiac MRI to examine age-related differences in LV structure and function in 5004 participants without overt cardiovascular disease when enrolled in the Multi-Ethnic Study of Atherosclerosis; 1099 participants received additional strain analyses by MRI tagging. We also assessed the relation of age-associated remodeling with cardiovascular outcomes using Cox proportional hazard models adjusting for cardiovascular risk factors. Although LV mass decreased with age (-0.3 g per year), the mass-to-volume ratio markedly increased (+5 mg/mL per year, Pfall in stroke volume (-0.4 mL per year, P or =65 years; hazard ratio, 1.68 [CI 0.77 to 3.68]) individuals with the highest compared to lowest mass-to-volume ratio quintile (P(interaction)=0.013). Age is associated with a phenotype of LV remodeling marked by increased mass-to-volume ratio and accompanied by systolic as well as diastolic myocardial dysfunction that is not reflected by preserved ejection fraction. This pattern of ventricular remodeling confers significant cardiovascular risk, particularly when present earlier in life.

  5. Evaluation of Accordance of Magnetic Resonance Volumetric and Flow Measurements in Determining Ventricular Stroke Volume in Cardiac Patients

    International Nuclear Information System (INIS)

    Jeltsch, M.; Ranft, S.; Klass, O.; Aschoff, A.J.; Hoffmann, M.H.K.

    2008-01-01

    Background: Cardiovascular magnetic resonance imaging (CMR) has become an established noninvasive method for evaluating ventricular function utilizing three-dimensional volumetry. Postprocessing of volumetric measurements is still tedious and time consuming. Stroke volumes obtained by flow quantification across the aortic root or pulmonary trunk could be utilized to increase both speed of workflow and accuracy. Purpose: To assess accuracy of stroke volume quantification using MR volumetric imaging compared to flow quantification in patients with various cardiac diseases. Strategies for the augmentation of accuracy in clinical routine were deduced. Material and Methods: 78 patients with various cardiac diseases -excluding intra- or extracardiac shunts, regurgitant valvular defects, or heart rhythm disturbance -underwent cardiac function analysis with flow measurements across the aortic root and cine imaging of the left ventricle. Forty-six patients additionally underwent flow measurements in the pulmonary trunk and cine imaging of the right ventricle. Results: Left ventricular stroke volume (LVSV) and stroke volume of the aortic root (SVAo) correlated with r=0.97, and Bland-Altman analysis showed a mean difference of 0.11 ml and a standard error of estimation (SEE) of 4.31 ml. Ninety-two percent of the data were within the 95% limits of agreement. Right ventricular stroke volume (RVSV) and stroke volume of the pulmonary trunk (SVP) correlated with a factor of r=0.86, and mean difference in the Bland-Altman analysis was fixed at -2.62 ml (SEE 8.47 ml). For RVSV and SVP, we calculated r=0.82, and Bland-Altman analysis revealed a mean difference of 1.27 ml (SEE 9.89 ml). LVSV and RVSV correlated closely, with r=0.91 and a mean difference of 2.79 ml (SEE 7.17 ml). SVAo and SVP correlated with r=0.95 and a mean difference of 0.50 ml (SEE 5.56 ml). Conclusion: Flow quantification can be used as a guidance tool, providing accurate and reproducible stroke volumes of both

  6. Rupture of Sinus of Valsalva Aneurysm Associated with Left Ventricular Noncompaction and Mitral Valve Prolapse

    Directory of Open Access Journals (Sweden)

    Sinan Aydoğdu

    2011-08-01

    Full Text Available We report a 27-year-old patient with ruptured sinus Valsalva aneurysm (SVA, left ventricular noncompaction and mitral valve prolapse. Whether the coexistence of ruptured SVA, left ventricular noncompaction and mitral valve prolapse is coincidental or due to a defect in a common developmental pathway requires further research.

  7. The accuracy of ventricular volume measurement and the optimal slice thickness by using multislice helical computed tomography

    International Nuclear Information System (INIS)

    Cui Wei; Guo Yuyin

    2005-01-01

    Objective: To determine the optimal slice thickness for ventricular volume measurement by tomographic multislice Simpson's method and to evaluate the accuracy of ventricular volume measured by multislice helical computed tomography (MSCT) in human ventricular casts. Methods: Fourteen human left ventricular (LV) and 15 right ventricular (RV) casts were scanned with MSCT scanner by using a scanning protocol similar to clinical practice. A series of LV and RV short-axis images were reconstructed with slice thickness of 2 mm, 3.5 mm, 5 mm, 7 mm, and 10 mm, respectively. Multislice Simpson's method was used to calculate LV and RV volumes and true cast volume was determined by water displacement. Results: The true LV and RV volumes were (55.57 ± 28.91) ml, and (64.23 ± 24.51) ml, respectively. The calculated volumes from different slice thickness ranged from (58.78 ± 28.93) ml to (68.15 ± 32.57) ml for LV casts, and (74.45 ± 27.81) ml to (88.14 ± 32.91) ml for RV casts, respectively. Both the calculated LV and RV volumes correlated closely with the corresponding true volumes (all r > 0.95, P<0.001), but overestimated the corresponding true volume by (3.21 ± 5.95) to (12.58 ± 8.56) ml for LV and (10.22 ± 8.45) to (23.91 ± 12.24) ml for RV (all P<0.01). There was a close correlation between the overestimation and the selected slice thickness for both LV and RV volume measurements (r=0.998 and 0.996, P<0.001). However, when slice thickness was reduced to 5.0 mm, the overestimation became nonsignificant for slice thickness through 2.0 mm to 5.0 mm, and also for both LV and RV volume measurements. Conclusion: Both LV and RV volumes can be accurately calculated with MSCT. A 5 mm slice thickness is enough and most efficient for accurate measurement of LV and RV volume. (authors)

  8. Alteration of left ventricular endocardial function by intracavitary high-power ultrasound interacts with volume, inotropic state, and alpha 1-adrenergic stimulation

    NARCIS (Netherlands)

    de Hert, S. G.; Gillebert, T. C.; Brutsaert, D. L.

    1993-01-01

    BACKGROUND: High-power intracavitary ultrasound abbreviates left ventricular (LV) ejection duration, thereby decreasing mechanical LV performance, presumably by selective impairment of endocardial endothelial function. METHODS AND RESULTS: Effects of ultrasound were evaluated in the ejecting LV of

  9. Assessment of ejection fraction of the right and left ventricles in patients with acute myocardial infarction by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Zhang, Youyi; Imai, Kamon; Araki, Yasushi; Nishino, Yukari; Saito, Satoshi; Ozawa, Yukio; Yasugi, Tadao

    1993-01-01

    Right and left ventricular function in acute myocardial infarction (AMI) was assessed by ECG-gated magnetic resonance imaging (MRI) in 64 patients and 8 volunteers. Five short axis images for intrinsic cardiac long-axis of the left ventricle were obtained at 9 msec and 309 msec after the R wave as end-diastole and end-systole. Right and left ventricular volumes were measured by Simpson's rule. The intraobserver variabilities in right and left ventricular ejection fraction (RVEF: r=0.94, LVEF: 0.89) were excellent. The interobserver variabilities in RVEF (r=0.61) and LVEF (r=0.77) were fair. LVEF, but not RVEF, was significantly reduced in patients with AMI. Among left ventricular dysfunction (LVEF≤40%) patients, 50% exhibited right ventricular dysfunction (RVEF≤40%). Among patients without left ventricular dysfunction, only 12% exhibited right ventricular dysfunction. In left ventricular and biventricular dysfunction compared with control, the left ventricular end-diastolic volume index increased (65±10 ml/m 2 , 68±12 ml/m 2 vs 54±8 ml/m 2 ), the end-systolic volume index increased (40±16 ml/m 2 , 43±7 ml/m 2 vs 18±1 ml/m 2 ), and the right ventricular end-diastolic volume index decreased (52±13 ml/m 2 , 53±20 ml/m 2 vs 65±8 ml/m 2 ). MRI can thus be used to assess ventricular systolic function. Since patients with left ventricular dysfunction revealed a high incidence of right ventricular dysfunction, an interaction between the left and right ventricles may occur in ventricular dysfunction. (author)

  10. The effect of heart rate and contractility on the measurement of left ventricular mass by 201Tl SPECT

    International Nuclear Information System (INIS)

    Machac, J.; Vaquer, R.; Levin, H.; Horowitz, S.F.; Mount Sinai Medical Center, New York

    1987-01-01

    Left ventricular myocardial mass can be measured by 201 Tl SPECT, but the effects of changes in heart rate and contractility have not been determined. We constructed a dynamic computer model simulating the contracting left ventricle. Thirty two summed static views at each of 3 heart rates and 3 ejection fractions were manufactured to simulate a 180 0 acquisition. Each image set underwent tomographic reconstruction. Left ventricular mass was measured at a fixed percent threshold in each slice. The results show that left ventricular mass varied little with heart rate (4%) and only slightly more (8%) with ejection fraction. Thus, in the normal clinical setting, left ventricular mass measurements by SPECT are minimally affected by the dynamic state of the heart. (orig.)

  11. Increased left ventricular mass in normotensive type 1 diabetic patients with diabetic nephropathy

    DEFF Research Database (Denmark)

    Sato, A; Tarnow, L; Parving, H H

    1998-01-01

    in normotensive type 1 diabetic patients with and without nephropathy. RESEARCH DESIGN AND METHODS: M-mode and Doppler echocardiography was performed in 17 type 1 diabetic patients with nephropathy (albuminuria [median (range)], 345 (135-2,846) mg/24 h) and compared with 34 normotensive, normoalbuminuric (10 [3......-30] mg/24 h) type 1 diabetic patients matched for arterial blood pressure (mean +/- SD) ([134/77] +/- [13/7] vs. [129/78] +/- [12/7] mmHg), age (40 +/- 11 vs. 42 +/- 10 years), duration of diabetes (28 +/- 7 vs. 28 +/- 6 years), and BMI (24.2 +/- 4.2 vs. 24.6 +/- 2.4 kg/m2). RESULTS: Left ventricular......OBJECTIVE: Diabetic nephropathy increases the risk of premature cardiovascular disease and sudden death, particularly in type 1 diabetic patients. One possible mechanism for this risk may be left ventricular hypertrophy. In our study, we aimed to evaluate left ventricular structure and function...

  12. His-Purkinje system-related incessant ventricular tachycardia arising from the left coronary cusp

    Directory of Open Access Journals (Sweden)

    Eiji Sato, MD

    2014-08-01

    Full Text Available We describe the case of a 23-year-old woman who had His-Purkinje system-related incessant ventricular tachycardia with a narrow QRS configuration. The ventricular tachycardia was ablated successfully in the left coronary cusp where the earliest endocardial activation had been recorded. We hypothesize that a remnant of the subaortic conducting tissue was the source of the ventricular arrhythmias.

  13. [Rare cause of heart failure in an elderly woman in Djibouti: left ventricular non compaction].

    Science.gov (United States)

    Massoure, P L; Lamblin, G; Bertani, A; Eve, O; Kaiser, E

    2011-10-01

    The purpose of this report is to describe the first case of left ventricular non compaction diagnosed in Djibouti. The patient was a 74-year-old Djiboutian woman with symptomatic heart failure. Echocardiography is the key tool for assessment of left ventricular non compaction. This rare cardiomyopathy is probably underdiagnosed in Africa.

  14. Prevalence, clinical significance, and natural history of left ventricular apical aneurysms in hypertrophic cardiomyopathy.

    Science.gov (United States)

    Maron, Martin S; Finley, John J; Bos, J Martijn; Hauser, Thomas H; Manning, Warren J; Haas, Tammy S; Lesser, John R; Udelson, James E; Ackerman, Michael J; Maron, Barry J

    2008-10-07

    Hypertrophic cardiomyopathy (HCM) is the most common genetic heart disease characterized by a diverse clinical and phenotypic spectrum. This study reports the prevalence, morphology, clinical course, and management of an underrecognized subgroup of HCM patients with left ventricular apical aneurysms. Of 1299 HCM patients, 28 (2%) were identified with left ventricular apical aneurysms, including a pair of identical twins. Aneurysms were recognized at a wide age range (26 to 83 years), including 12 patients (43%) who were rims, and were associated with transmural (and often more extensive) myocardial scarring identified by late gadolinium enhancement cardiovascular magnetic resonance. Apical aneurysms were recognized by echocardiography in only 16 of 28 patients (57%) but by cardiovascular magnetic resonance in the 12 patients undetected by echocardiography. Left ventricular chamber morphology varied; however, 19 patients (68%) showed an "hourglass" contour, with midventricular hypertrophy producing muscular narrowing and intracavitary gradients in 9 patients (74+/-42 mm Hg). Sarcomeric protein missense mutations known to cause other phenotypic expressions of HCM were present in 3 patients. Over 4.1+/-3.7 years of follow-up, 12 patients (43%) with left ventricular apical aneurysms experienced adverse disease complications (event rate, 10.5%/y), including sudden death, appropriate implantable cardioverter-defibrillator discharges, nonfatal thromboembolic stroke, and progressive heart failure and death. Patients with left ventricular apical aneurysms represent an underappreciated subset in the heterogeneous HCM disease spectrum with important clinical implications, often requiring a high index of suspicion and cardiovascular magnetic resonance for identification. Apical aneurysms in HCM are associated with substantial cardiovascular morbidity and mortality and raise novel treatment considerations.

  15. Pressure-independent relationship of aortic characteristic impedance with left ventricular mass and geometry in untreated hypertension.

    Science.gov (United States)

    Pucci, Giacomo; Hametner, Bernhard; Battista, Francesca; Wassertheurer, Siegfried; Schillaci, Giuseppe

    2015-01-01

    We investigated whether aortic characteristic impedance (Zc), that is, the ratio between the pulsatile change in pressure and flow in the proximal aorta, is related to left ventricular hypertrophy and geometry independently of blood pressure (BP). A total of 438 never-treated hypertensive individuals (men 62%, age 48 ± 11 years, BP 147/90 ± 16/10  mm Hg) underwent echocardiography and 24 h BP monitoring. Aortic pressure waveform was obtained from radial tonometry with a generalized transfer function (SphygmoCor). Using a validated aortic blood flow model based on higher order Windkessel theory (ARCSolver), aortic Zc, forward (Pf) and backward (Pb) wave amplitudes and their ratio (Pb/Pf = reflection magnitude) were calculated from central waveform. After adjusting for age, BMI, and 24-h SBP, aortic Zc was higher in individuals with left ventricular hypertrophy (0.230 ± 0.09 vs. 0.205 ± 0.07 arbitrary units, P = 0.04 in women; 0.232 ± 0.07 vs. 0.214 ± 0.06 arbitrary units, P < 0.05 in men). Women with left ventricular concentric remodeling had higher adjusted Zc (0.225 ± 0.08 vs. 0.203 ± 0.07 arbitrary units, P = 0.04), whereas men did not differ (0.218 ± 0.07 vs. 0.218 ± 0.07 arbitrary units, P = 0.64). After controlling for age, BMI, 24 h SBP, and other relevant variables, aortic Zc independently predicted left ventricular mass (β = 0.14, P < 0.05) and relative wall thickness (β = 0.21, P < 0.01) in women, and left ventricular mass in men (β = 0.11, P < 0.05), whereas other arterial function parameters had no independent relation with left ventricular mass or geometry. Aortic Zc has a significant association with left ventricular mass and a sex-specific one with left ventricular concentric geometry in hypertension. These effects are independent from, and additional to, those of 24 h SBP.

  16. Effect of preload reduction by hemodialysis on left atrial volume and echocardiographic Doppler parameters in patients with end-stage renal disease.

    Science.gov (United States)

    Barberato, Silvio H; Mantilla, Diego E V; Misocami, M Arcio; Gonçalves, Simone M; Bignelli, Alexandre T; Riella, Miguel C; Pecoits-Filho, Roberto

    2004-11-01

    Left atrial (LA) volume has been proposed as a less preload-dependent parameter of diastolic function than Doppler mitral inflow. We hypothesize that in the absence of mitral regurgitation and atrial fibrilation, LA enlargement could be a more practical (and relatively preload-independent) method for the evaluation of left ventricular diastolic function. The aim of the present study was to determine the effects of preload reduction by hemodialysis on LA volume.

  17. Gender specific pattern of left ventricular cardiac adaptation to ...

    African Journals Online (AJOL)

    EB

    2013-09-03

    Sep 3, 2013 ... Some gender specific associations with left ventricular structure and function have been described ... used for analysis. ... risk due to LVH and that cardiac adaptation to ... had history taking, physical examination and ..... between the gender specific differences in cardiac ... A metaanalysis of individual.

  18. Rapid estimation of left ventricular ejection fraction in acute myocardial infarction by echocardiographic wall motion analysis

    DEFF Research Database (Denmark)

    Berning, J; Rokkedal Nielsen, J; Launbjerg, J

    1992-01-01

    Echocardiographic estimates of left ventricular ejection fraction (ECHO-LVEF) in acute myocardial infarction (AMI) were obtained by a new approach, using visual analysis of left ventricular wall motion in a nine-segment model. The method was validated in 41 patients using radionuclide...

  19. Left ventricular structure and function in black normotensive type 2 ...

    African Journals Online (AJOL)

    Keywords: Black normotensive patients, left ventricular function, type 2 DM. Résumé ... sickle cell disease and structural heart disease were excluded ... Pulmonary venous flow (PVF) velocity ... had abnormal ECG pattern compared with 30%.

  20. Effects of milrinone on left ventricular cardiac function during cooling in an intact animal model.

    Science.gov (United States)

    Tveita, Torkjel; Sieck, Gary C

    2012-08-01

    Due to adverse effects of β-receptor agonists reported when applied during hypothermia, left ventricular (LV) cardiac effects of milrinone, a PDE3 inhibitor which mode of action is deprived the sarcolemmal β-receptor-G protein-PKA system, was tested during cooling to 15 °C. Sprague Dawley rats were instrumented to measure left ventricular (LV) pressure-volume changes using a Millar pressure-volume conductance catheter. Core temperature was reduced from 37 to 15 °C (60 min) using internal and external heat exchangers. Milrinone, or saline placebo, was given as continuous i.v. infusions for 30 min at 37 °C and during cooling. In normothermic controls continuous milrinone infusion for 90 min elevated cardiac output (CO) and stroke volume (SV) significantly. Significant differences in cardiac functional variables between the milrinone group and the saline control group during cooling to 15 °C were found: Compared to saline treated animals throughout cooling from 33 to 15 °CSV was significantly elevated in milrinone animals, the index of LV isovolumic relaxation, Tau, was significantly better preserved, and both HR and CO were significantly higher from 33 to 24 °C. Likewise, during cooling between 33 and 28 °C also LVdP/dt(max) was significantly higher in the milrinone group. Milrinone preserved LV systolic and diastolic function at a significantly higher level than in saline controls during cooling to 15 °C. In essential contrast to our previous results when using β-receptor agonists during hypothermia, the present experiment demonstrates the positive inotropic effects of milrinone on LV cardiac function during cooling to 15 °C. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. Improved detection of anterior left ventricular aneurysm with multiharmonic fourier analysis

    International Nuclear Information System (INIS)

    Valette, H.B.; Bourguignon, M.H.; Merlet, P.; Gregoire, M.C.; Le Guludec, D.; Pascal, O.; Briandet, P.; Syrota, A.

    1990-01-01

    Single and multiharmonic Fourier analysis of LAO 30-45 degrees gated blood-pool studies were performed in a selected group of 30 patients with a left ventricular anterior aneurysm proven by contrast angiography. The sensitivity of the first harmonic phase image for the diagnosis of ventricular aneurysm was 80%. The clear phase shift (greater than 110 degrees) between the normal and the aneurysmal areas was missing in six patients. Peak acceleration images (negative maximum of the second derivative of the Fourier series) were calculated for each pixel with the analytical Fourier formula using two or three harmonics. A clear phase shift (greater than 126 degrees) than appeared in all the patients. This improvement was related to the increased weight of the second and third harmonics in the aneurysmal area when compared to control patients or to patients with dilative cardiomyopathy. Multiharmonic Fourier analysis clearly improved the sensitivity of the diagnosis of anterior left ventricular aneurysm on LAO 30 degrees-45 degrees gated blood-pool images

  2. Left ventricular functional, structural and energetic effects of normal aging: Comparison with hypertension.

    Directory of Open Access Journals (Sweden)

    Jehill D Parikh

    Full Text Available Both aging and hypertension are significant risk factors for heart failure in the elderly. The purpose of this study was to determine how aging, with and without hypertension, affects left ventricular function.Cross-sectional study of magnetic resonance imaging and 31P spectroscopy-based measurements of left ventricular structure, global function, strains, pulse wave velocity, high energy phosphate metabolism in 48 normal subjects and 40 treated hypertensive patients (though no other cardiovascular disease or diabetes stratified into 3 age deciles from 50-79 years.Normal aging was associated with significant increases in systolic blood pressure, vascular stiffness, torsion, and impaired diastolic function (all P<0.05. Age-matched hypertension exacerbated the effects of aging on systolic pressure, and diastolic function. Hypertension alone, and not aging, was associated with increased left ventricular mass index, reduced energetic reserve, reduced longitudinal shortening and increased endocardial circumferential shortening (all P<0.05. Multiple linear regression analysis showed that these unique hypertensive features were significantly related to systolic blood pressure (P<0.05.1 Hypertension adds to the age-related changes in systolic blood pressure and diastolic function; 2 hypertension is uniquely associated with changes in several aspects of left ventricular structure, function, systolic strains, and energetics; and 3 these uniquely hypertensive-associated parameters are related to the level of systolic blood pressure and so are potentially modifiable.

  3. Quantitative assessment of left ventricular systolic function using 3-dimensional echocardiography

    Directory of Open Access Journals (Sweden)

    Rahul Mehrotra

    2013-09-01

    Full Text Available Assessment of left ventricular systolic function is the commonest and one of the most important indications for performance of echocardiography. It is important for prognostication, determination of treatment plan, for decisions related to expensive device therapies and for assessing response to treatment. The current methods based on two-dimensional echocardiography are not reliable, have high degree of inter-observer and intra-observer variability and are based on presumptions about the geometry of left ventricle (LV. Real-time three-dimensional echocardiography (RT3DE on the other hand is fast, easy, accurate, relatively operator independent and is not based on any assumptions related to the shape of LV. Owing to these advantages, it is the Echocardiographic modality of choice for assessment of systolic function of the LV. We describe here a step by step approach to evaluation of LV volumes, ejection fraction, regional systolic function and Dyssynchrony analysis based on RT3DE. It has been well validated in clinical studies and is rapidly being incorporated in routine clinical practice.

  4. Correlation of radiological assessment of congestive heart failure with left ventricular end-diastolic pressure

    International Nuclear Information System (INIS)

    Herman, P.G.; Kahn, A.; Kallman, C.E.; Rojas, K.A.; Bodenheimer, M.M.

    1988-01-01

    Left ventricular end-diastolic pressure (LVEDP) has been considered a reliable indicator of left ventricular function. The purpose of this study was to correlate the radiologic assessment of congestive heart failure with LVEDP. The population of the study consisted of 85 consecutive cases in four ranges of LVEDP ( 24). The PA chest radiographs obtained 1 day prior to cardiac catherization were assessed for radiological evidence of congestive heart failure and were graded from normal to abnormal (0-3). The results will be summarized in the authors' presentation. The discordance of radiological assessment of congestive heart failure in patients with elevated LVEDP will be discussed in light of recent advances in pathophysiologic understanding of left ventricular function and the impact of new classes of drugs in the management of these patients

  5. Evaluation of training nurses to perform semi-automated three-dimensional left ventricular ejection fraction using a customised workstation-based training protocol.

    Science.gov (United States)

    Guppy-Coles, Kristyan B; Prasad, Sandhir B; Smith, Kym C; Hillier, Samuel; Lo, Ada; Atherton, John J

    2015-06-01

    We aimed to determine the feasibility of training cardiac nurses to evaluate left ventricular function utilising a semi-automated, workstation-based protocol on three dimensional echocardiography images. Assessment of left ventricular function by nurses is an attractive concept. Recent developments in three dimensional echocardiography coupled with border detection assistance have reduced inter- and intra-observer variability and analysis time. This could allow abbreviated training of nurses to assess cardiac function. A comparative, diagnostic accuracy study evaluating left ventricular ejection fraction assessment utilising a semi-automated, workstation-based protocol performed by echocardiography-naïve nurses on previously acquired three dimensional echocardiography images. Nine cardiac nurses underwent two brief lectures about cardiac anatomy, physiology and three dimensional left ventricular ejection fraction assessment, before a hands-on demonstration in 20 cases. We then selected 50 cases from our three dimensional echocardiography library based on optimal image quality with a broad range of left ventricular ejection fractions, which was quantified by two experienced sonographers and the average used as the comparator for the nurses. Nurses independently measured three dimensional left ventricular ejection fraction using the Auto lvq package with semi-automated border detection. The left ventricular ejection fraction range was 25-72% (70% with a left ventricular ejection fraction nurses showed excellent agreement with the sonographers. Minimal intra-observer variability was noted on both short-term (same day) and long-term (>2 weeks later) retest. It is feasible to train nurses to measure left ventricular ejection fraction utilising a semi-automated, workstation-based protocol on previously acquired three dimensional echocardiography images. Further study is needed to determine the feasibility of training nurses to acquire three dimensional echocardiography

  6. The management of patients with aortic regurgitation and severe left ventricular dysfunction: a systematic review.

    Science.gov (United States)

    Badar, Athar A; Brunton, Alan P T; Mahmood, Ammad H; Dobbin, Stephen; Pozzi, Andrea; McMinn, Jenna F; Sinclair, Andrew J E; Gardner, Roy S; Petrie, Mark C; Curry, Phil A; Al-Attar, Nawwar H K; Pettit, Stephen J

    2015-01-01

    A systematic search of Medline, EMBASE and CINAHL electronic databases was performed. Original research articles reporting all-cause mortality following surgery in patients with aortic regurgitation and severe left ventricular systolic dysfunction (LVSD) were identified. Nine of the 10 eligible studies were observational, single-center, retrospective analyses. Survival ranged from 86 to 100% at 30 days; 81 to 100% at 1 year and 68 to 84% at 5 years. Three studies described an improvement in mean left ventricular ejection fraction (LVEF) following aortic valve replacement (AVR) of 5-14%; a fourth study reported an increase in mean left ventricular ejection fraction (LVEF) of 9% in patients undergoing isolated AVR but not when AVR was combined with coronary artery bypass graft and/or mitral valve surgery. Three studies demonstrated improvements in functional New York Heart Association (NYHA) class following AVR. Additional studies are needed to clarify the benefits of AVR in patients with more extreme degrees of left ventricular systolic dysfunction (LVSD) and the potential roles of cardiac transplantation and transaortic valve implantation.

  7. Adeno-associated Virus Serotype 9 – Driven Expression of BAG3 Improves Left Ventricular Function in Murine Hearts with Left Ventricular Dysfunction Secondary to a Myocardial Infarction

    Science.gov (United States)

    Knezevic, Tijana; Myers, Valerie D.; Su, Feifei; Wang, JuFang; Song, Jianliang; Zhang, Xue-Qian; Gao, Erhe; Gao, Guofeng; Muniswamy, Madesh; Gupta, Manish K.; Gordon, Jennifer; Weiner, Kristen N.; Rabinowitz, Joseph; Ramsey, Frederick V.; Tilley, Douglas G.; Khalili, Kamel; Cheung, Joseph Y.; Feldman, Arthur M.

    2016-01-01

    Objectives The present study was undertaken to test the hypothesis that gene delivery of BCL2-Associated Athanogene 3 (BAG3) to the heart of mice with left ventricular dysfunction secondary to a myocardial infarction could enhance cardiac performance. Background BAG3 is a 575 amino acid protein that has pleotropic functions in the cell including pro-autophagy and anti-apoptosis. Mutations in BAG3 have been associated with both skeletal muscle dysfunction and familial dilated cardiomyopathy and BAG3 levels are diminished in non-familial heart failure. Methods Eight-week-old C57/BL6 mice underwent ligation of the left coronary artery (MI) or sham surgery (Sham). Eight weeks later, mice in both groups were randomly assigned to receive either a retro-orbital injection of rAAV9-BAG3 (MI-BAG3 or Sham-BAG3) or rAAV9-GFP (MI-GFP or Sham GFP). Mice were sacrificed at 3 weeks post-injection and myocytes were isolated from the left ventricle. Results MI-BAG3 mice demonstrated a significantly (p BAG3 injection with further improvement in LVEF, fractional shortening and stroke volume at 3 weeks post-injection without changes in LV mass or LV volume. Injection of rAAV9-BAG3 had no effect on LVEF in Sham mice. The salutary benefits of rAAV9-BAG3 were also observed in myocytes isolated from MI hearts including improved cell shortening (pBAG3 gene therapy may provide a novel therapeutic option for the treatment of heart failure. PMID:28164169

  8. Influence of microalbuminuria on left ventricular geometry and function in hypertensive patients with type 2 diabetes mellitus.

    Science.gov (United States)

    Picca, Maurizio; Agozzino, Francesco; Pelosi, Giancarlo

    2003-01-01

    An increased urinary albumin excretion (UAE) is associated with an augmented risk of cardiovascular disease in diabetic patients and in non-diabetic subjects. Left ventricular hypertrophy has been demonstrated to be a powerful predictor of cardiovascular morbidity and mortality in arterial hypertension and when the ventricular geometry is concentric the relation is even stronger. This echocardiographic and Doppler study was designed to evaluate the influence of microalbuminuria on the left ventricular geometry and function in hypertensive patients with type 2 diabetes melitus. Forty-two patients (16 males, 26 females, mean age 59.6 +/- 6.7 years) with mild-to-moderate essential hypertension and type 2 diabetes mellitus were enrolled in the study. Twenty-one patients had an elevated UAE (group 1) and 21 a normal UAE (group 2). M-mode (under two-dimensional control) and Doppler echocardiography were performed after a 4-week washout period off antihypertensive therapy. The left ventricular mass index was found to be greater than the partition value of 51 g/m2.7 in both groups but was significantly higher (p diabetes mellitus, an elevated UAE is associated with an increased left ventricular mass index, a higher prevalence of a concentric left ventricular hypertrophy pattern, a depressed midwall systolic performance and a markedly impaired diastolic function...

  9. Primary cardiac tumor presenting as left ventricular outflow tract obstruction and complex arrhythmia.

    Science.gov (United States)

    Fries, R; Achen, S; O'Brien, M T; Jackson, N D; Gordon, S

    2017-10-01

    An adult female mixed breed dog presented for recurrent collapsing episodes over several weeks. Holter evaluation revealed periods of sinus arrest and echocardiography identified a soft tissue mass with subsequent severe dynamic obstruction of the left ventricular outflow tract. The patient was euthanized five days after presentation for severe dyspnea. Necropsy revealed an irregular mass circumferentially lining the left ventricular outflow tract as well as multiple myocardial metastases. The final diagnosis was an undifferentiated pleomorphic endocardial sarcoma. Published by Elsevier B.V.

  10. Extraction and analysis of left ventricular contours in cardiac radionuclide angiographies

    International Nuclear Information System (INIS)

    Jouan, A.

    1991-01-01

    The analysis of cardiac scintigraphic sequences is commonly realized with the help of functional or parametric images. The decomposition of the original sequence into a linear combination of the main temporal behaviors yields, after orthogonalization, a set of parametric images representing the pure temporal behaviors present in the original data. The properties of these images are used to extract automatically the left ventricular boundary. The Fourier Descriptors method is then used to get a quantified analysis of the shape of the ventricle. Because of their property of invariance by change of scale, the Fourier descriptors method applied on a sequence of left ventricular contours yields a quantified assessment of the cardiac contraction

  11. Guiding automated left ventricular chamber segmentation in cardiac imaging using the concept of conserved myocardial volume.

    Science.gov (United States)

    Garson, Christopher D; Li, Bing; Acton, Scott T; Hossack, John A

    2008-06-01

    The active surface technique using gradient vector flow allows semi-automated segmentation of ventricular borders. The accuracy of the algorithm depends on the optimal selection of several key parameters. We investigated the use of conservation of myocardial volume for quantitative assessment of each of these parameters using synthetic and in vivo data. We predicted that for a given set of model parameters, strong conservation of volume would correlate with accurate segmentation. The metric was most useful when applied to the gradient vector field weighting and temporal step-size parameters, but less effective in guiding an optimal choice of the active surface tension and rigidity parameters.

  12. Evaluation with equilibrium radionuclide angiography of left ventricular systolic and diastolic function in pulmonary hypertension secondary to chronic pulmonary diseases

    International Nuclear Information System (INIS)

    Inoue, Kazuya; Sera, Kazuaki; Fukuzaki, Hisashi.

    1989-01-01

    To evaluate left ventricular systolic and diastolic function in patients with pulmonary hypertension secondary to chronic pulmonary diseases, 86 patients were studied using equilibrium radionuclide angiography with forward and reverse gating from the R wave. At rest left ventricular function, both in systolic and diastolic properties, in patients with pulmonary hypertension was significantly lower than in normal subjects (LVEF; P<0.05, PER; P<0.05, PFR; P<0.025, FF; P<0.025). During exercise left ventricular systolic function did not increase as much as in normals (LVEF; N.S., PER; N.S.). Left ventricular diastolic function during exercise was significantly lower than at rest (PFR; P<0.05, FF; P<0.001). The indices of left ventricular function obtained from radionuclide angiography had no close correlation with pulmonary hemodynamics or with blood gases. These results demonstrated that left ventricular dysfunction in patients with pulmonary hypertension was observed both at rest and during exercise, and might play an important role in reduced exercise tolerance. (author)

  13. Evaluation with equilibrium radionuclide angiography of left ventricular systolic and diastolic function in pulmonary hypertension secondary to chronic pulmonary diseases

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Kazuya; Sera, Kazuaki [National Akashi Hospital, Hyogo (Japan); Fukuzaki, Hisashi

    1989-08-01

    To evaluate left ventricular systolic and diastolic function in patients with pulmonary hypertension secondary to chronic pulmonary diseases, 86 patients were studied using equilibrium radionuclide angiography with forward and reverse gating from the R wave. At rest left ventricular function, both in systolic and diastolic properties, in patients with pulmonary hypertension was significantly lower than in normal subjects (LVEF; P<0.05, PER; P<0.05, PFR; P<0.025, FF; P<0.025). During exercise left ventricular systolic function did not increase as much as in normals (LVEF; N.S., PER; N.S.). Left ventricular diastolic function during exercise was significantly lower than at rest (PFR; P<0.05, FF; P<0.001). The indices of left ventricular function obtained from radionuclide angiography had no close correlation with pulmonary hemodynamics or with blood gases. These results demonstrated that left ventricular dysfunction in patients with pulmonary hypertension was observed both at rest and during exercise, and might play an important role in reduced exercise tolerance. (author).

  14. Relation of the Number of Parity to Left Ventricular Diastolic Function in Pregnancy.

    Science.gov (United States)

    Keskin, Muhammed; Avşar, Şahin; Hayıroğlu, Mert İlker; Keskin, Taha; Börklü, Edibe Betül; Kaya, Adnan; Uzun, Ahmet Okan; Akyol, Burcu; Güvenç, Tolga Sinan; Kozan, Ömer

    2017-07-01

    Left ventricular diastolic dysfunction (LVDD) has been relatively less studied than other cardiac changes during pregnancy. Previous studies revealed a mild diastolic deterioration during pregnancy. However, these studies did not evaluate the long-term effect of parity on left ventricular diastolic function. A comprehensive study evaluating the long-term effect of parity on diastolic function is required. A total of 710 women with various number of parity were evaluated through echocardiography to reveal the status of diastolic function. Echocardiographic parameters were compared among the women by parity number and categorized accordingly: none, 0 to 4 and 4 4 parity and that had 21 and 5.8 times higher than nulliparous group, respectively. In conclusion, according to the present study, grand multiparity but not multiparity, severely deteriorates left ventricular diastolic function. Further studies are warranted to evaluate the risk of gradual diastolic dysfunction after each pregnancy. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Systemic Embolization from an Unusual Intracardiac Mass in the Left Ventricular Outflow Tract

    Directory of Open Access Journals (Sweden)

    Kelechukwu U. Okoro

    2017-01-01

    Full Text Available Endocarditis can affect any endocardial surface; in the vast majority of cases, the cardiac valves are involved. It is exceedingly rare to develop infective endocarditis on the endocardium of the left ventricular outflow tract due to the high velocity of blood that traverses this area. Herein, we present a rare case of left ventricular outflow tract endocarditis that likely occurred secondary to damage to the aortic valve leaflets (from healed prior aortic valve endocarditis causing a high velocity aortic valve regurgitant jet that impinged upon the interventricular septum which damaged the endocardium and resulted in a fibrotic “jet lesion.” This fibrous jet lesion served as a nidus for bacterial proliferation and vegetation formation. The high shear stress (due to high blood flow velocity through the left ventricular outflow tract likely promoted the multiple embolic events observed in this case. Our patient was successfully treated with aortic valve replacement, vegetation resection, and antibiotics.

  16. Assessment of left ventricular function and mass in dual-source computed tomography coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, Christoph J., E-mail: c.jensen@contilia.d [Department of Cardiology and Angiology, Elisabeth Hospital, Essen (Germany); Jochims, Markus [Department of Cardiology and Angiology, Elisabeth Hospital, Essen (Germany); Hunold, Peter; Forsting, Michael; Barkhausen, Joerg [Department of Diagnostic and Interventional Radiology and Neuroradiology, University of Essen (Germany); Sabin, Georg V.; Bruder, Oliver [Department of Cardiology and Angiology, Elisabeth Hospital, Essen (Germany); Schlosser, Thomas [Department of Diagnostic and Interventional Radiology and Neuroradiology, University of Essen (Germany)

    2010-06-15

    Purpose: To quantify left ventricular (LV) function and mass (LVM) derived from dual-source computed tomography (DSCT) and the influence of beta-blocker administration compared to cardiac magnetic resonance imaging (CMR). Methods: Thirty-two patients undergoing cardiac DSCT and CMR were included, where of fifteen received metoprolol intravenously before DSCT. LV parameters were calculated by the disc-summation method (DSM) and by a segmented region-growing algorithm (RGA). All data sets were analyzed by two blinded observers. Interobserver agreement was tested by the intraclass correlation coefficient. Results.: 1. Using DSM LV parameters were not statistically different between DSCT and CMR in all patients (DSCT vs. CMR: EF 63 {+-} 8% vs. 64 {+-} 8%, p = 0.47; EDV 136 {+-} 36 ml vs. 138 {+-} 35 ml, p = 0.66; ESV 52 {+-} 21 ml vs. 52 {+-} 22 ml, p = 0.61; SV 83 {+-} 22 ml vs. 87 {+-} 19 ml, p = 0.22; CO 5.4 {+-} 0.9 l/min vs. 5.7 {+-} 1.2 l/min, p = 0.09, LVM 132 {+-} 33 g vs. 132 {+-} 33 g, p = 0.99). 2. In a subgroup of 15 patients beta-blockade prior to DSCT resulted in a lower ejection fraction (EF), stroke volume (SV), cardiac output (CO) and increase in end systolic volume (ESV) in DSCT (EF 59 {+-} 8% vs. 62 {+-} 9%; SV 73 {+-} 17 ml vs. 81 {+-} 15 ml; CO 5.7 {+-} 1.2 l/min vs. 5.0 {+-} 0.8 l/min; ESV 52 {+-} 27 ml vs. 57 {+-} 24 ml, all p < 0.05). 3. Analyzing the RGA parameters LV volumes were not significantly different compared to DSM, whereas LVM was higher using RGA (177 {+-} 31 g vs. 132 {+-} 33 g, p < 0.05). Interobserver agreement was excellent comparing DSM values with best agreement between RGA calculations. Conclusion: Left ventricular volumes and mass can reliably be assessed by DSCT compared to CMR. However, beta-blocker administration leads to statistically significant reduced EF, SV and CO, whereas ESV significantly increases. DSCT RGA reliably analyzes LV function, whereas LVM is overestimated compared to DSM.

  17. Adeno-Associated Virus Serotype 9–Driven Expression of BAG3 Improves Left Ventricular Function in Murine Hearts With Left Ventricular Dysfunction Secondary to a Myocardial Infarction

    Directory of Open Access Journals (Sweden)

    Tijana Knezevic, PhD

    2016-12-01

    Full Text Available Mutations in Bcl-2–associated athanogene 3 (BAG3 were associated with skeletal muscle dysfunction and dilated cardiomyopathy. Retro-orbital injection of an adeno-associated virus serotype 9 expressing BAG3 (rAAV9-BAG3 significantly (p < 0.0001 improved left ventricular ejection fraction, fractional shortening, and stroke volume 9 days post-injection in mice with cardiac dysfunction secondary to a myocardial infarction. Furthermore, myocytes isolated from mice 3 weeks after injection showed improved cell shortening, enhanced systolic [Ca2+]i and increased [Ca2+]i transient amplitudes, and increased maximal L-type Ca2+ current amplitude. These results suggest that BAG3 gene therapy may provide a novel therapeutic option for the treatment of heart failure.

  18. Synthetic Marijuana Induced Acute Nonischemic Left Ventricular Dysfunction.

    Science.gov (United States)

    Elsheshtawy, Moustafa; Sriganesh, Priatharsini; Virparia, Vasudev; Patel, Falgun; Khanna, Ashok

    2016-01-01

    Synthetic marijuana is an uptrending designer drug currently widely spread in the US. We report a case of acute deterioration of nonischemic left ventricular dysfunction after exposure to synthetic marijuana. This case illustrates the importance of history taking in cardiac patients and identifies a negative cardiovascular effect of synthetic marijuana known as K2, not yet well detected by urine toxicology screening tools.

  19. Synthetic Marijuana Induced Acute Nonischemic Left Ventricular Dysfunction

    OpenAIRE

    Moustafa Elsheshtawy; Priatharsini Sriganesh; Vasudev Virparia; Falgun Patel; Ashok Khanna

    2016-01-01

    Synthetic marijuana is an uptrending designer drug currently widely spread in the US. We report a case of acute deterioration of nonischemic left ventricular dysfunction after exposure to synthetic marijuana. This case illustrates the importance of history taking in cardiac patients and identifies a negative cardiovascular effect of synthetic marijuana known as K2, not yet well detected by urine toxicology screening tools.

  20. Short-term assessment of left ventricular function, coronary hemodynamics, and catecholamine balance in severe congestive heart failure after a single oral dose of milrinone

    NARCIS (Netherlands)

    F. Piscione; B.E. Jaski; P.W.J.C. Serruys (Patrick)

    1988-01-01

    textabstractSystemic and coronary hemodynamics were measured before and every 10 min after oral milrinone (10 mg) administration for 50 min, together with the drug plasma level in 14 patients with congestive heart failure. Left ventricular pressure (tip manometry), volume (angiography), and derived

  1. Contemporary Assessment of Left Ventricular Diastolic Function in Older Adults

    DEFF Research Database (Denmark)

    Shah, Amil M.; Claggett, Brian; Kitzman, Dalane

    2017-01-01

    Background: Although age-Associated changes in left ventricular diastolic function are well recognized, limited data exist characterizing measures of diastolic function in older adults, including both reference ranges reflecting the older adult population and prognostically relevant values...

  2. Left ventricular systolic function in sickle cell anaemia: an ...

    African Journals Online (AJOL)

    Keywords: Left ventricular systolic function, sickle cell anaemia, echocardiographic evaluation, adult Nigerian patients. ..... Quadratic .505. -0.390. 12.231. 8.587 .001*. Cubic .510. -0.180. 8.264. 8.619 .001*. This relationship was further evaluated by means of scat- ter plots and subsequently by regression analysis. The.

  3. Relationship Between 24-Hour Ambulatory Central Systolic Blood Pressure and Left Ventricular Mass: A Prospective Multicenter Study.

    Science.gov (United States)

    Weber, Thomas; Wassertheurer, Siegfried; Schmidt-Trucksäss, Arno; Rodilla, Enrique; Ablasser, Cornelia; Jankowski, Piotr; Lorenza Muiesan, Maria; Giannattasio, Cristina; Mang, Claudia; Wilkinson, Ian; Kellermair, Jörg; Hametner, Bernhard; Pascual, Jose Maria; Zweiker, Robert; Czarnecka, Danuta; Paini, Anna; Salvetti, Massimo; Maloberti, Alessandro; McEniery, Carmel

    2017-12-01

    We investigated the relationship between left ventricular mass and brachial office as well as brachial and central ambulatory systolic blood pressure in 7 European centers. Central systolic pressure was measured with a validated oscillometric device, using a transfer function, and mean/diastolic pressure calibration. M-mode images were obtained by echocardiography, and left ventricular mass was determined by one single reader blinded to blood pressure. We studied 289 participants (137 women) free from antihypertensive drugs (mean age: 50.8 years). Mean office blood pressure was 145/88 mm Hg and mean brachial and central ambulatory systolic pressures were 127 and 128 mm Hg, respectively. Mean left ventricular mass was 93.3 kg/m 2 , and 25.6% had left ventricular hypertrophy. The correlation coefficient between left ventricular mass and brachial office, brachial ambulatory, and central ambulatory systolic pressure was 0.29, 0.41, and 0.47, respectively ( P =0.003 for comparison between brachial office and central ambulatory systolic pressure and 0.32 for comparison between brachial and central ambulatory systolic pressure). The results were consistent for men and women, and young and old participants. The areas under the curve for prediction of left ventricular hypertrophy were 0.618, 0.635, and 0.666 for brachial office, brachial, and central ambulatory systolic pressure, respectively ( P =0.03 for comparison between brachial and central ambulatory systolic pressure). In younger participants, central ambulatory systolic pressure was superior to both other measurements. Central ambulatory systolic pressure, measured with an oscillometric cuff, shows a strong trend toward a closer association with left ventricular mass and hypertrophy than brachial office/ambulatory systolic pressure. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01278732. © 2017 American Heart Association, Inc.

  4. Nuclear medical determination of left ventricular diastolic function in coronary heart disease

    International Nuclear Information System (INIS)

    Brugger, P.; Laesser, W.K.; Kullich, W.; Stoiberer, I.; Klein, G.

    1985-01-01

    In 64 patients with coronary heart disease, the left ventricular diastolic function was determined by means of a new nuclear medical method (nuclear stethoscope). The investigations revealed an abnormal diastolic filling in 85.9% of the cases on the basis of the parameters peak filling rate and time to peak filling rate as manifestation of a disturbed ventricular function

  5. Left ventricular function in hypertrophic cardiomyopathy

    International Nuclear Information System (INIS)

    Takahashi, Hiromi; Yamaguchi, Ryutaro; Ifuku, Masayasu

    1985-01-01

    The present study was to investigate of left ventricular (LV) function during exercise in 26 patients with hypertrophic cardiomyopathy(HCM) usingTc-99m equilibrium angiocardiography, and to elucidate the mechanism of impaired functional reserve during exercise. In patients with HCM, LV ejection fraction decreased from 65 ± 8 (mean ± SD) % at rest to 59 ± 18 % at peak exercise, in contrast to an increase among controls (from 56 ± 9 % to 64 ± 9 %). As compared with resting values, cardiac output increased to 168 ± 24 % at peak exercise in HCM, but the increase was significantly less than that in controls (215 ± 47 %). Stroke volume decreased gradually to 83 ± 16 % during exercise in HCM, while it increased to 114 ± 10 % at an exercise level of half intensity, and it decreased slightly to 106 ± 16 % at peak exercise. LV end-systolic volume decreased among controls to 78 ± 27 % at peak exercise, but remained unchanged in HCM (118 ± 58 %). An increase in peak ejection rate at peak exercise was less in HCM than in controls (143 ± 26 % vs 170 ± 42 %). No significant differences were observed between the two groups concerning changes in indices of LV diastolic function including LV end-diastolic volume, peak filling rate or 1/3 filling rate during exercise. In the analysis of LV function curves, pulmonary arterial diastolic pressure increased to a greater extent in HCM than in controls (19 ± 6 mmHg vs 11 ± 6 mmHg); whereas, an increase in the stroke work index was less in HCM (80 ± 26 g.m/m 2 /beat vs 121 ± 21 g.m/m 2 /beat) at peak exercise. Thus, the LV function curve shifted downward and to the right in patients with HCM. The above findings indicate that LV functional reserve during exercise is impaired, especially as to systolic function in patients with HCM, while deterioration of diastolic function may be partly compromised by elevated filling pressure. (J.P.N.)

  6. Quantitation of global and regional left ventricular function by MRI

    NARCIS (Netherlands)

    van der Geest, RJ; Reiber, JHC; Reiber, JHC; VanDerWall, EE

    1998-01-01

    Magnetic resonance imaging (MRI) provides several imaging strategies for assessing left ventricular function. As a three-dimensional imaging technique, all measurements can be performed without relying on geometrical assumptions. Global and regional function parameters can be derived from

  7. Noninvasive evaluation of global and regional left ventricular function using computed tomography and magnetic resonance imaging: a meta-analysis

    International Nuclear Information System (INIS)

    Kaniewska, Malwina; Schuetz, Georg M.; Willun, Steffen; Dewey, Marc; Schlattmann, Peter

    2017-01-01

    To compare the diagnostic accuracy of computed tomography (CT) in the assessment of global and regional left ventricular (LV) function with magnetic resonance imaging (MRI). MEDLINE, EMBASE and ISI Web of Science were systematically reviewed. Evaluation included: ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and left ventricular mass (LVM). Differences between modalities were analysed using limits of agreement (LoA). Publication bias was measured by Egger's regression test. Heterogeneity was evaluated using Cochran's Q test and Higgins I"2 statistic. In the presence of heterogeneity the DerSimonian-Laird method was used for estimation of heterogeneity variance. Fifty-three studies including 1,814 patients were identified. The mean difference between CT and MRI was -0.56 % (LoA, -11.6-10.5 %) for EF, 2.62 ml (-34.1-39.3 ml) for EDV and 1.61 ml (-22.4-25.7 ml) for ESV, 3.21 ml (-21.8-28.3 ml) for SV and 0.13 g (-28.2-28.4 g) for LVM. CT detected wall motion abnormalities on a per-segment basis with 90 % sensitivity and 97 % specificity. CT is accurate for assessing global LV function parameters but the limits of agreement versus MRI are moderately wide, while wall motion deficits are detected with high accuracy. (orig.)

  8. Noninvasive evaluation of global and regional left ventricular function using computed tomography and magnetic resonance imaging: a meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kaniewska, Malwina; Schuetz, Georg M.; Willun, Steffen; Dewey, Marc [Charite - Universitaetsmedizin Berlin, Department of Radiology, Berlin (Germany); Schlattmann, Peter [Jena University Hospital, Department of Medical Statistics, Informatics and Documentation, Jena (Germany)

    2017-04-15

    To compare the diagnostic accuracy of computed tomography (CT) in the assessment of global and regional left ventricular (LV) function with magnetic resonance imaging (MRI). MEDLINE, EMBASE and ISI Web of Science were systematically reviewed. Evaluation included: ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and left ventricular mass (LVM). Differences between modalities were analysed using limits of agreement (LoA). Publication bias was measured by Egger's regression test. Heterogeneity was evaluated using Cochran's Q test and Higgins I{sup 2} statistic. In the presence of heterogeneity the DerSimonian-Laird method was used for estimation of heterogeneity variance. Fifty-three studies including 1,814 patients were identified. The mean difference between CT and MRI was -0.56 % (LoA, -11.6-10.5 %) for EF, 2.62 ml (-34.1-39.3 ml) for EDV and 1.61 ml (-22.4-25.7 ml) for ESV, 3.21 ml (-21.8-28.3 ml) for SV and 0.13 g (-28.2-28.4 g) for LVM. CT detected wall motion abnormalities on a per-segment basis with 90 % sensitivity and 97 % specificity. CT is accurate for assessing global LV function parameters but the limits of agreement versus MRI are moderately wide, while wall motion deficits are detected with high accuracy. (orig.)

  9. Left ventricular function assessment using a fast 3D gradient echo pulse sequence: comparison to standard multi-breath hold 2D steady state free precession imaging and accounting for papillary muscles and trabeculations.

    Science.gov (United States)

    Sievers, Burkhard; Schrader, Sebastian; Rehwald, Wolfgang; Hunold, Peter; Barkhausen, Joerg; Erbel, Raimund

    2011-06-01

    Papillary muscles and trabeculae for ventricular function analysis are known to significantly contribute to accurate volume and mass measurements. Fast imaging techniques such as three-dimensional steady-state free precession (3D SSFP) are increasingly being used to speed up imaging time, but sacrifice spatial resolution. It is unknown whether 3D SSFP, despite its reduced spatial resolution, allows for exact delineation of papillary muscles and trabeculations. We therefore compared 3D SSFP ventricular function measurements to those measured from standard multi-breath hold two-dimensional steady-state free precession cine images (standard 2D SSFP). 14 healthy subjects and 14 patients with impaired left ventricularfunction underwent 1.5 Tesla cine imaging. A stack of short axis images covering the left ventricle was acquired with 2D SSFP and 3D SSFP. Left ventricular volumes, ejection fraction, and mass were determined. Analysis was performed by substracting papillary muscles and trabeculae from left ventricular volumes. In addition, reproducibility was assessed. EDV, ESV, EF, and mass were not significantly different between 2D SSFP and 3D SSFP (mean difference healthy subjects: -0.06 +/- 3.2 ml, 0.54 +/- 2.2 ml, -0.45 +/- 1.8%, and 1.13 +/- 0.8 g, respectively; patients: 1.36 +/- 2.8 ml, -0.15 3.5 ml, 0.86 +/- 2.5%, and 0.91 +/- 0.9 g, respectively; P > or = 0.095). Intra- and interobserver variability was not different for 2D SSFP (P > or = 0.64 and P > or = 0.397) and 3D SSFP (P > or = 0.53 and P > or = 0.47). Differences in volumes, EF, and mass measurements between 3D SSFP and standard 2D SSFP are very small, and not statistically significant. 3D SSFP may be used for accurate ventricular function assessment when papillary muscles and trabeculations are to be taken into account.

  10. Three dimensional endo-cardiovascular volume-rendered cine computed tomography of isolated left ventricular apical hypoplasia; A case report and literature review

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Sun Hwa; Kim, Yang Min; Lee, Hyun Jong [Sejong General Hospital, Bucheon (Korea, Republic of)

    2016-02-15

    We report multidetector computed tomography (MDCT) and cardiac magnetic resonance (CMR) findings of a 34-year-old female with isolated left ventricular apical hypoplasia. The MDCT and CMR scans displayed a spherical left ventricle (LV) with extensive fatty infiltration within the myocardium at the apex, interventricular septum and inferior wall, anteroapical origin of the papillary muscle, right ventricle wrapping around the deficient LV apex, and impaired systolic function. MDCT visualized morphologic and also functional findings of this unique cardiomyopathy.

  11. Left Ventricular Diastolic Function and Characteristics in Fetal Aortic Stenosis

    Science.gov (United States)

    Friedman, Kevin G.; Schidlow, David; Freud, Lindsay; Escobar-Diaz, Maria; Tworetzky, Wayne

    2014-01-01

    Fetal aortic valvuloplasty (FAV) has shown promise in averting progression of mid-gestation aortic stenosis (AS) to hypoplastic left heart syndrome in a subset of patients. Patients who achieve biventricular circulation after FAV frequently have left ventricular (LV) diastolic dysfunction (DD). This study evaluates DD in fetuses with AS by comparing echocardiographic indices of LV diastolic function in fetuses undergoing FAV (n=20) to controls (n=40) and evaluates for LV factors associated with DD in FAV patients. We also compared pre- and post-FAV DD variables (n=16). Median gestational age (24 weeks, range 18–29 weeks) and fetal heart rate were similar between FAV and controls. Compared to controls, FAV patients had universally abnormal LV diastolic parameters including fused mitral inflow E and A waves (p=0.008), higher E velocity(p<0.001), shorter mitral inflow time (p=0.001), lower LV lateral annulus E′ (p<0.001), septal E′ (p=0.003) and higher E/E′ (p<0.001) than controls. FAV patients had abnormal right ventricular mechanics with higher tricuspid inflow E velocity (p<0.001), and shorter tricuspid inflow time (p=0.03). Worse LV diastolic function (lower LV E′) was associated with higher endocardial fibroelastosis (EFE) grade (r=0.74, p<0.001), large LV volume (r=0.55, p=0.013) and sphericity (r=0.58, P=0.009) and with lower LV pressure by mitral regurgitation jet (r=−0.68, p<0.001). Post-FAV, fewer patients had fused mitral inflow E and A than pre-FAV (p=0.05) and septal E′ was higher (=0.04). In conclusion, fetuses with mid-gestation AS have evidence of marked DD. Worse DD is associated with larger, more spherical LV, with more extensive EFE and lower LV pressure. PMID:24819899

  12. Detection and evaluation of left atrial myxoma by gated radionuclide imaging

    International Nuclear Information System (INIS)

    Sugihara, Hiroki; Adachi, Haruhiko; Nakagawa, Hiroaki

    1985-01-01

    Radionuclide imaging plays an important role in diagnosising left atrial myxoma (LAM). We discussed diagnostic value of Fourier analysis with phase image and evaluated left ventricular filling function using indices such as 1/3 Filling Fraction, Rapid Filling Fraction and Peak Filling Rate derived from left ventricular volume curve. Equillibrium radionuclide angiocardiography was performed in 6 LAM patients. Phase delay in the basal portion of the left ventricle was shown in 5 of 6 LAM patients, and standard deviation of left ventricular phase was larger than these of controls. Left ventricular filling disturbance was suggested in 5 of 6 LAM patients. After surgical remove of myxoma phase delay was disappeared and standard deviation was normalized. And left ventricular filling was improved. We concluded that the phase image of Fourier analysis revealed a left atrial mass prolapsing in the left ventricule during the diastole, and that diastolic indices were useful for left ventricular filling disturbance due to LAM. (author)

  13. Right ventricular function after acute myocardial infarction: dependence upon infarct related coronary artery

    International Nuclear Information System (INIS)

    Cho, Ihn Ho; Chun, Kyung A; Won, Kyu Chang; Lee, Hyung Woo; Hong, Geu Ru; Park, Jong Seon; Shin, Dong Gu; Kim, Young Jo; Shim, Bong Sub

    2004-01-01

    We studied to know the relation between right ventricular function and infarct-related artery after acute myocardial infarction. The right and left ventricular function after a first myocardial infarction was assessed ECG-gated blood pool single photon emission computed tomography (GBPS) algorithms (Cedars-Sinai Medical Center, Los Angels, Calif) (12 after LAD related infarction (group 1) and 15 after RCA related infarction (group 2)). The left ventricular ejection fraction, end-diastolic volume and end-systolic volume did not differ significantly between two groups( group 1 vs 2 :LVEF 50.8% vs 55.1%. LVEDV=73.2 vs 79.7 ml, LVESV=38 vs 44 ml : P>0.05), but right ventricular ejection fraction, end-diastolic volume and end-systolic volume were significantly different after anterior myocardial infarction between two groups( group 1 vs 2 : RVEF=57.3% vs 46.3%. RVEDV=56.4 vs 95.1 ml, RVESV=25.6 vs 54.6ml : P<0.05). There was evidence of right ventricular dilatation in the group with RCA related infarction. Six with inferior infarction had abnormal right ventricular ejection fractions (< 40%). The relation between right and left ventricular ejection fractions was markedly different in the two groups. In the group with RCA related infarction there was a significant linear relation between right and left ventricular ejection fraction(R=0.5). Whereas in the group with LAD related infarction there was not (R=-0.3). Thus right ventricular dysfunction commonly occurs after RCA related infarction. Right ventricular impairment is related after RCA related infarction, but are independent after LAD related infarction. Finally, the different effects of LAD and RCA related infarction on right ventricular function may be explained by site of the myocardial wall involvement after infarction

  14. Left ventricular wall motion abnormalities evaluated by factor analysis as compared with Fourier analysis

    International Nuclear Information System (INIS)

    Hirota, Kazuyoshi; Ikuno, Yoshiyasu; Nishikimi, Toshio

    1986-01-01

    Factor analysis was applied to multigated cardiac pool scintigraphy to evaluate its ability to detect left ventricular wall motion abnormalities in 35 patients with old myocardial infarction (MI), and in 12 control cases with normal left ventriculography. All cases were also evaluated by conventional Fourier analysis. In most cases with normal left ventriculography, the ventricular and atrial factors were extracted by factor analysis. In cases with MI, the third factor was obtained in the left ventricle corresponding to wall motion abnormality. Each case was scored according to the coincidence of findings of ventriculography and those of factor analysis or Fourier analysis. Scores were recorded for three items; the existence, location, and degree of asynergy. In cases of MI, the detection rate of asynergy was 94 % by factor analysis, 83 % by Fourier analysis, and the agreement in respect to location was 71 % and 66 %, respectively. Factor analysis had higher scores than Fourier analysis, but this was not significant. The interobserver error of factor analysis was less than that of Fourier analysis. Factor analysis can display locations and dynamic motion curves of asynergy, and it is regarded as a useful method for detecting and evaluating left ventricular wall motion abnormalities. (author)

  15. Measurement of four chambers' volumes and ventricular masses by cardiac CT examination

    International Nuclear Information System (INIS)

    Kimura, Motomasa; Naito, Hiroaki; Ohta, Mitsushige; Kozuka, Takahiro; Kito, Yoshitsugu

    1983-01-01

    Using cardiac computed tomography (CT), the ''mean'' volume of each cardiac chamber and both ventricular masses were calculated from summation of a sliced volume by ungated scans obtained using rapid sequential scanning covering the whole heart. 1. Estimation of a normal value of each chamber's volume was attempted in 20 patients with ischemic heart disease and with normal heart function. The ''mean'' volume of the right atrium (RAMV), right ventricle (RVMV), and left atrium (LAMV) was 22.3 +- 6.5, 40.3 +- 6.5 and 28.7 +- 8.2ml/m 2 , respectively. 2. In 54 patients with valvular heart diseases, each chamber's volume obrained by CT was compared with the grade of tricuspid regurgitation (TR) estimated by ultrasonic Doppler technique or the grade of mitral regurgitation (MR) by left ventriculography (LVG). The RAMV (234 +- 119 ml/m 2 ) and the RVMV (101 +- 39 ml/m 2 ) were markedly increased in patients with severe TR (grade 3 to 4) (p 2 ) was also increased in patients with severe mitral regurgitation (grade 3 to 4) (p<0.01). 3. In 46 patients with valvular heart diseases, the LVMV by CT was well correlated with end-diastolic volume (EDV) obtained by LVG (r=0.92), and the LVEDVs by ECG gated CT and by LVG showed a fairly good correlation (r=0.95). 4. CT examination was performed before and after surgery in 17 patients with MR or TR for evaluation of the change of chamber volumes. The mean reduction ratio (MRR) of the RAMV after tricuspid annuloplasty, the LVMV after mitral valve plasty, and the LAMV after left atrial plication was 44%, 41%, and 60%, respectively. (author)

  16. Effect of chronic right ventricular apical pacing on left ventricular function.

    Science.gov (United States)

    O'Keefe, James H; Abuissa, Hussam; Jones, Philip G; Thompson, Randall C; Bateman, Timothy M; McGhie, A Iain; Ramza, Brian M; Steinhaus, David M

    2005-03-15

    The determinants of change in left ventricular (LV) ejection fraction (EF) over time in patients with impaired LV function at baseline have not been clearly established. Using a nuclear database to assess changes in LV function over time, we included patients with a baseline LVEF of 25% to 40% on a gated single-photon emission computed tomographic study at rest and only if second-gated photon emission computed tomography performed approximately 18 months after the initial study showed an improvement in LVEF at rest of > or =10 points or a decrease in LVEF at rest of > or =7 points. In all, 148 patients qualified for the EF increase group and 59 patients for the EF decrease group. LVEF on average increased from 33 +/- 4% to 51 +/- 8% in the EF increase group and decreased from 35 +/- 4% to 25 +/- 5% in the EF decrease group. The strongest multivariable predictor of improvement of LVEF was beta-blocker therapy (odds ratio 3.9, p = 0.002). The strongest independent predictor of LVEF decrease was the presence of a permanent right ventricular apical pacemaker (odds ratio 6.6, p = 0.002). Thus, this study identified beta-blocker therapy as the major independent predictor for improvement in LVEF of > or =10 points, whereas a permanent pacemaker (right ventricular apical pacing) was the strongest predictor of a LVEF decrease of > or =7 points.

  17. Left ventricular outflow tract to left atrial communication secondary to rupture of mitral-aortic intervalvular fibrosa in infective endocarditis: diagnosis by transesophageal echocardiography and color flow imaging.

    Science.gov (United States)

    Bansal, R C; Graham, B M; Jutzy, K R; Shakudo, M; Shah, P M

    1990-02-01

    Infection of the mitral-aortic intervalvular fibrosa occurs most commonly in association with infective endocarditis of the aortic valve. Infection of the aortic valve results in a regurgitant jet that presumably strikes this subaortic interannular zone of fibrous tissue and produces a secondary site of infection. Infection of this interannular zone then leads to the formation of subaortic abscess or pseudoaneurysm of the left ventricular outflow tract. This infected zone of mitral-aortic intervalvular fibrosa or subaortic aneurysm can subsequently rupture into the left atrium with systolic ejection of blood from the left ventricular outflow tract to the left atrium. This report describes the echocardiographic findings in three patients with pathologically proved left ventricular outflow tract to left atrial communication. Precise preoperative diagnosis is important, and this lesion should be differentiated from ruptured aneurysm of the sinus of Valsalva and perforation of the anterior mitral leaflet. Transthoracic echocardiography using color flow imaging and conventional Doppler techniques may show an eccentric mitral regurgitation type of signal in the left atrium originating from the region of the left ventricular outflow tract. However, transesophageal echocardiography provides an accurate preoperative diagnosis and should be used intraoperatively during repair of such lesions.

  18. Association of HeartMate II left ventricular assist device flow estimate with thermodilution cardiac output.

    Science.gov (United States)

    Hasin, Tal; Huebner, Marianne; Li, Zhuo; Brown, Daniel; Stulak, John M; Boilson, Barry A; Joyce, Lyle; Pereira, Naveen L; Kushwaha, Sudhir S; Park, Soon J

    2014-01-01

    Cardiac output (CO) assessment is important in treating patients with heart failure. Durable left ventricular assist devices (LVADs) provide essentially all CO. In currently used LVADs, estimated device flow is generated by a computerized algorithm. However, LVAD flow estimate may be inaccurate in tracking true CO. We correlated LVAD (HeartMate II) flow with thermodilution CO during postoperative care (day 2-10 after implant) in 81 patients (5,616 paired measurements). Left ventricular assist device flow and CO correlated with a low correlation coefficient (r = 0.42). Left ventricular assist device readings were lower than CO measurements by approximately 0.36 L/min, trending for larger difference with higher values. Left ventricular assist device flow measurements showed less temporal variability compared with CO. Grouping for simultaneous measured blood pressure (BP device flow generally trends with measured CO, but large variability exists, hence flow measures should not be assumed to equal with CO. Clinicians should take into account variables such as high CO, BP, and opening of the aortic valve when interpreting LVAD flow readout. Direct flow sensors incorporated in the LVAD system may allow for better estimation.

  19. Synthetic Marijuana Induced Acute Nonischemic Left Ventricular Dysfunction

    Directory of Open Access Journals (Sweden)

    Moustafa Elsheshtawy

    2016-01-01

    Full Text Available Synthetic marijuana is an uptrending designer drug currently widely spread in the US. We report a case of acute deterioration of nonischemic left ventricular dysfunction after exposure to synthetic marijuana. This case illustrates the importance of history taking in cardiac patients and identifies a negative cardiovascular effect of synthetic marijuana known as K2, not yet well detected by urine toxicology screening tools.

  20. Age and gender specific normal values of left ventricular mass, volume and function for gradient echo magnetic resonance imaging: a cross sectional study

    Directory of Open Access Journals (Sweden)

    Allansdotter-Johnsson Ase

    2009-01-01

    Full Text Available Abstract Background Knowledge about age-specific normal values for left ventricular mass (LVM, end-diastolic volume (EDV, end-systolic volume (ESV, stroke volume (SV and ejection fraction (EF by cardiac magnetic resonance imaging (CMR is of importance to differentiate between health and disease and to assess the severity of disease. The aims of the study were to determine age and gender specific normal reference values and to explore the normal physiological variation of these parameters from adolescence to late adulthood, in a cross sectional study. Methods Gradient echo CMR was performed at 1.5 T in 96 healthy volunteers (11–81 years, 50 male. Gender-specific analysis of parameters was undertaken in both absolute values and adjusted for body surface area (BSA. Results Age and gender specific normal ranges for LV volumes, mass and function are presented from the second through the eighth decade of life. LVM, ESV and EDV rose during adolescence and declined in adulthood. SV and EF decreased with age. Compared to adult females, adult males had higher BSA-adjusted values of EDV (p = 0.006 and ESV (p Conclusion LV volumes, mass and function vary over a broad age range in healthy individuals. LV volumes and mass both rise in adolescence and decline with age. EF showed a rapid decline in adolescence compared to changes throughout adulthood. These findings demonstrate the need for age and gender specific normal ranges for clinical use.

  1. Tl scintiscanning hemodynamics and left ventricular kinetics in patients to be suspected of myocardial sarcoidosis

    International Nuclear Information System (INIS)

    Schaedel, H.; Kirsten, D.; Strauss, H.J.; Haenselt, V.; Schmidt, H.; Gottschild, D.; Zinner, G.

    1985-01-01

    The cardiological examination of 22 patients to be suspected of heart sarcoidosis (histologically established sarcoidosis, heart rhythm disturbances, cardiomegaly) has revealed thallium scan defects in 20 patients at rest and during exercise. In 19 patients pathologic left heart wall motions established by levocardiography applying the half axis method were found. The number of pathologic half axis shortenings correlated with ejection fraction, but not with left ventricular enddiastolic pressure and volume index, resp. Coronary heart disease could not be found by coronarography in any case. Myocardial biopsy did not show myocarditis. Cardiomyopathies, other specific heart muscle diseases or rheumatic myocarditis could not be excluded as causes of the results mentioned above. The follow-up examinations of the patients will give more detailed information on the etiology of the pathologic cardiac findings. (author)

  2. The influence of adrenergic stimulation on sex differences in left ventricular twist mechanics.

    Science.gov (United States)

    Williams, Alexandra M; Shave, Rob E; Cheyne, William S; Eves, Neil D

    2017-06-15

    Sex differences in left ventricular (LV) mechanics occur during acute physiological challenges; however, it is unknown whether sex differences in LV mechanics are fundamentally regulated by differences in adrenergic control. Using two-dimensional echocardiography and speckle tracking analysis, this study compared LV mechanics in males and females matched for LV length during post-exercise ischaemia (PEI) and β 1 -adrenergic receptor blockade. Our data demonstrate that while basal rotation was increased in males, LV twist was not significantly different between the sexes during PEI. In contrast, during β 1 -adrenergic receptor blockade, LV apical rotation, twist and untwisting velocity were reduced in males compared to females. Significant relationships were observed between LV twist and LV internal diameter and sphericity index in females, but not males. These findings suggest that LV twist mechanics may be more sensitive to alterations in adrenergic stimulation in males, but more highly influenced by ventricular structure and geometry in females. Sex differences in left ventricular (LV) mechanics exist at rest and during acute physiological stress. Differences in cardiac autonomic and adrenergic control may contribute to sex differences in LV mechanics and LV haemodynamics. Accordingly, this study aimed to investigate sex differences in LV mechanics with altered adrenergic stimulation achieved through post-handgrip-exercise ischaemia (PEI) and β 1 -adrenergic receptor (AR) blockade. Twenty males (23 ± 5 years) and 20 females (22 ± 3 years) were specifically matched for LV length (males: 8.5 ± 0.5 cm, females: 8.2 ± 0.6 cm, P = 0.163), and two-dimensional speckle-tracking echocardiography was used to assess LV structure and function at baseline, during PEI and following administration of 5 mg bisoprolol (β 1 -AR antagonist). During PEI, LV end-diastolic volume and stroke volume were increased in both groups (P adrenergic stimulation

  3. Comparison of indium-111 platelet scintigraphy and two-dimensional echocardiography in the diagnosis of left ventricular thrombi

    International Nuclear Information System (INIS)

    Ezekowitz, M.D.; Wilson, D.A.; Smith, E.O.; Burow, R.D.; Harrison, L.H. Jr.; Parker, D.E.; Elkins, R.C.; Peyton, M.; Taylor, F.B.

    1982-01-01

    In a study comparing indium-111 platelet scintigraphy and two-dimensional echocardiography as methods of identifying left ventricular thrombi, the results obtained with both techniques were verified at surgery or autopsy in 53 patients-34 with left ventricular aneurysms, and 19 with mitral-valve disease. Left ventricular thrombi were found at surgery or autopsy in 14 of the patients with aneurysms and in none of those with mitral-valve disease. Thirteen of 53 echocardiograms (25%) were technically inadequate and excluded from the analysis. In the group with aneurysms, the sensitivity of scintigraphy in detecting thrombi was 71%, and that of echocardiography was 77%. The specificity of scintigraphy was 100%, and that of echocardiography was 93%. We conclude that indium-111 platelet scintigraphy and two-dimensional echocardiography have useful and complementary roles in the detection of left ventricular thrombi. Both these noninvasive techniques can be used to monitor therapy

  4. Three-dimensional Speckle Tracking Echocardiography in Light Chain Cardiac Amyloidosis: Examination of Left and Right Ventricular Myocardial Mechanics Parameters.

    Science.gov (United States)

    Urbano-Moral, Jose Angel; Gangadharamurthy, Dakshin; Comenzo, Raymond L; Pandian, Natesa G; Patel, Ayan R

    2015-08-01

    The study of myocardial mechanics has a potential role in the detection of cardiac involvement in patients with amyloidosis. This study aimed to characterize 3-dimensional-speckle tracking echocardiography-derived left and right ventricular myocardial mechanics in light chain amyloidosis and examine their relationship with brain natriuretic peptide. In patients with light chain amyloidosis, left ventricular longitudinal and circumferential strain (n=40), and right ventricular longitudinal strain and radial displacement (n=26) were obtained by 3-dimensional-speckle tracking echocardiography. Brain natriuretic peptide levels were determined. All myocardial mechanics measurements showed differences when compared by brain natriuretic peptide level tertiles. Left and right ventricular longitudinal strain were highly correlated (r=0.95, P<.001). Left ventricular longitudinal and circumferential strain were reduced in patients with cardiac involvement (-9±4 vs -16±2; P<.001, and -24±6 vs -29±4; P=.01, respectively), with the most prominent impairment at the basal segments. Right ventricular longitudinal strain and radial displacement were diminished in patients with cardiac involvement (-9±3 vs -17±3; P<.001, and 2.7±0.8 vs 3.8±0.3; P=.002). On multivariate analysis, left ventricular longitudinal strain was associated with the presence of cardiac involvement (odds ratio = 1.6; 95% confidence interval, 1.04 to 2.37; P=.03) independent of the presence of brain natriuretic peptide and troponin I criteria for cardiac amyloidosis. Three-dimensional-speckle tracking echocardiography-derived left and right ventricular myocardial mechanics are increasingly altered as brain natriuretic peptide increases in light chain amyloidosis. There appears to be a strong association between left ventricular longitudinal strain and cardiac involvement, beyond biomarkers such as brain natriuretic peptide and troponin I. Copyright © 2015 Sociedad Española de Cardiología. Published by

  5. Factors influencing left ventricular hypertrophy in children and adolescents with or without family history of premature myocardial infarction

    Directory of Open Access Journals (Sweden)

    Seyyed Mohsen Hosseini

    2014-01-01

    Result : The results showed that among the studied variables, gender, age, body mass index, and blood pressure were associated with the left ventricular hypertrophy. Conclusion: Considering the results and previous studies in this field, it was observed that left ventricular hypertrophy exists at early ages, which is very dangerous and can lead to heart diseases at early ages. Factors such as being overweight, having high blood pressure, and being male cause left ventricular hypertrophy and lead to undiagnosable heart diseases.

  6. Measurement of right ventricular volumes using 131I-MAA

    International Nuclear Information System (INIS)

    Sekimoto, T.; Grover, R.F.

    1975-01-01

    A method is presented for determining the right ventricular residual ratio, that is, the ratio of the end-systolic volume to the end-diastolic volume during each cardiac cycle. 131 I-MAA was injected as a bolus into the right ventricle, and the ratio of isotope remaining in the chamber during the succeeding cardiac cycles was determined with a collimated scintillation counter placed over the right ventricle. Since the counter detected the radioactivity from the entire right ventricular cavity, potential errors from incomplete mixing were minimized. The washout curve from the ventricle was distorted somewhat by the accumulation of isotope in intervening lung tissue. This distortion was eliminated by subtracting the build-up curve of radioactivity in the lung recorded simultaneously with a second scintillation counter positioned over the lateral chest wall. In 14 dogs anesthetized with chloralose, the right ventricular residual ratio was relatively constant at 40.4 +- 3.1 per cent. Duplicate measurements differed by less than 3 percent indicating the good reproducibility of the method. Right ventricular stroke volume was determined from cardiac output (dye dilution) and heart rate. With this and the simultaneously determined residual ratio ( 131 I-MAA), end-diastolic volume could be calculated. Stroke volume and stroke work were highly correlated with end-diastolic volume, in keeping with the Frank-Starling mechanism. (U.S.)

  7. Clinical impact of ' in-treatment' wall motion abnormalities in hypertensive patients with left ventricular hypertrophy: the LIFE study

    DEFF Research Database (Denmark)

    Cicala, S.; Simone, G. de; Wachtell, K.

    2008-01-01

    Objectives Left ventricular systolic wall motion abnormalities have prognostic value. Whether wall motion detected by serial echocardiographic examinations predicts prognosis in hypertensive patients with left ventricular hypertrophy ( LVH) without clinically recognized atherosclerotic disease ha...

  8. Left Ventricular Function and Physiological Performance in Female Ironman Athletes and Female Police Officers.

    Science.gov (United States)

    Leischik, Roman; Foshag, Peter; Strauss, Markus; Spelsberg, Norman

    2016-06-01

    Data about physiological performance of female ironman triathletes are rare. However, some studies have reported this endurance sport may cause damage to the right or left ventricles, even in females. The goal of this study was to assess prospectively the right/left ventricular function and physiological performance in female athletes (middle- and long ironman distance) and to compare the findings to female federal police officers. A total of 33 female triathletes and 37 female police officers were examined using spiro-ergometry and echocardiography. Female triathletes achieved VO2max 52.8 ± 5.7 ml/kg(-1)·min(-1), and police officers 35.3 ± 6.5 ml/kg(-1)·min(-1) In athletes, left ventricular end-diastolic diameter was 4.4 ± 0.3 cm and in police officers 4.5 ± 0.4 cm, and the left ventricular muscle mass index was 85.8 g/m(2 )± 18.7 in athletes and in police officers 72.0 g/m(2 )± 9.1. Right ventricular area change among athletes was 49.4 ± 8.5%, and in police officers 46.0 ± 6.9%. The performance date of female triathletes can be used as training prescription for leisure female triathletes, when middle or long distances in triathlon competitions are planned. No right or left ventricular dysfunction was found despite long training and finishing of long distance competitions: non-elite athletes, 5.4 ± 2.8 years of triathlon competitions; elite athletes, 7.6 ± 5.8 years. © The Author(s) 2016.

  9. Fluid loading and norepinephrine infusion mask the left ventricular preload decrease induced by pleural effusion.

    Science.gov (United States)

    Wemmelund, Kristian Borup; Ringgård, Viktor Kromann; Vistisen, Simon Tilma; Hyldebrandt, Janus Adler; Sloth, Erik; Juhl-Olsen, Peter

    2017-09-11

    Pleural effusion (PLE) may lead to low blood pressure and reduced cardiac output. Low blood pressure and reduced cardiac output are often treated with fluid loading and vasopressors. This study aimed to determine the impact of fluid loading and norepinephrine infusion on physiologic determinants of cardiac function obtained by ultrasonography during PLE. In this randomised, blinded, controlled laboratory study, 30 piglets (21.9 ± 1.3 kg) had bilateral PLE (75 mL/kg) induced. Subsequently, the piglets were randomised to intervention as follows: fluid loading (80 mL/kg/h for 1.5 h, n = 12), norepinephrine infusion (0.01, 0.03, 0.05, 0.1, 0.2 and 0.3 μg/kg/min (15 min each, n = 12)) or control (n = 6). Main outcome was left ventricular preload measured as left ventricular end-diastolic area. Secondary endpoints included contractility and afterload as well as global measures of circulation. All endpoints were assessed with echocardiography and invasive pressure-flow measurements. PLE decreased left ventricular end-diastolic area, mean arterial pressure and cardiac output (p values  0.05) to baseline. Left ventricular contractility increased with norepinephrine infusion (p = 0.002), but was not affected by fluid loading (p = 0.903). Afterload increased in both active groups (p values > 0.001). Overall, inferior vena cava distensibility remained unchanged during intervention (p values ≥ 0.085). Evacuation of PLE caused numerical increases in left ventricular end-diastolic area, but only significantly so in controls (p = 0.006). PLE significantly reduced left ventricular preload. Both fluid and norepinephrine treatment reverted this effect and normalised global haemodynamic parameters. Inferior vena cava distensibility remained unchanged. The haemodynamic significance of PLE may be underestimated during fluid or norepinephrine administration, potentially masking the presence of PLE.

  10. A microcomputerized system of nuclear probe for left ventricular function evaluation

    International Nuclear Information System (INIS)

    Piva, R.M.V.

    1987-01-01

    In this work, it is presented the development of a system, consisting in a nuclear probe and a 16 bits microcomputer, for left ventricular function (LVF) monitoring and analysis. Previously used in renal and thyroid studies, the nuclear probe, 2''x2''NaI(Tl) crystal, was adapted for its new application. The alterations include the design and construction of appropriate colimators and unterfacing to a strip-chart register and a magnetic tape recorder. After a single injection of Tc-99m labelling red blood cells, the probe is placed over the patient's chest on a convenient left anterior oblique position and a left ventricle time activity curve is obtained. This curve and the patient's eletrocardiogram (ECG) are recorded for posterior processing. The software, in PASCAL language, transfers the data from the magnetic tape to the microcomputer and provides the LVF and ECG curves to be displayed on beat-to-beat mode or as mean curves. From these curves one can extract ventricular parameter such as: ejection fraction, ejection rate, systolic and diastolic intervals and heart rate, by manually positioning three cursors on the points of interest. A critical evaluation of this method is performed and its advantages as well as its limitations are discussed. This approach provides an easy to operate and a low cost device that can be useful in many clinical situations, for example, the continuous monitoring in ICUs, the screening in out-patient departments. The assessment of drugs effects on left ventricular function is also possible. (author) [pt

  11. Quantitative right and left ventricular functional analysis during gated whole-chest MDCT: A feasibility study comparing automatic segmentation to semi-manual contouring

    International Nuclear Information System (INIS)

    Coche, Emmanuel; Walker, Matthew J.; Zech, Francis; Crombrugghe, Rodolphe de; Vlassenbroek, Alain

    2010-01-01

    Purpose: To evaluate the feasibility of an automatic, whole-heart segmentation algorithm for measuring global heart function from gated, whole-chest MDCT images. Material and methods: 15 patients with suspicion of PE underwent whole-chest contrast-enhanced MDCT with retrospective ECG synchronization. Two observers computed right and left ventricular functional indices using a semi-manual and an automatic whole-heart segmentation algorithm. The two techniques were compared using Bland-Altman analysis and paired Student's t-test. Measurement reproducibility was calculated using intraclass correlation coefficient. Results: Ventricular analysis with automatic segmentation was successful in 13/15 (86%) and in 15/15 (100%) patients for the right ventricle and left ventricle, respectively. Reproducibility of measurements for both ventricles was perfect (ICC: 1.00) and very good for automatic and semi-manual measurements, respectively. Ventricular volumes and functional indices except right ventricular ejection fraction obtained from the automatic method were significantly higher for the RV compared to the semi-manual methods. Conclusions: The automatic, whole-heart segmentation algorithm enabled highly reproducible global heart function to be rapidly obtained in patients undergoing gated whole-chest MDCT for assessment of acute chest pain with suspicion of pulmonary embolism.

  12. Impact of intracoronary injection of mononuclear bone marrow cells in acute myocardial infarction on left ventricular perfusion and function: a 6-month follow-up gated 99mTc-MIBI single-photon emission computed tomography study

    International Nuclear Information System (INIS)

    Lipiec, Piotr; Krzeminska-Pakula, Maria; Plewka, Michal; Kasprzak, Jaroslaw D.; Kusmierek, Jacek; Plachcinska, Anna; Szuminski, Remigiusz; Robak, Tadeusz; Korycka, Anna

    2009-01-01

    We investigated the impact of intracoronary injection of autologous mononuclear bone marrow cells (BMC) in patients with acute ST elevation myocardial infarction (STEMI) on left ventricular volumes, global and regional systolic function and myocardial perfusion. The study included 39 patients with first anterior STEMI treated successfully with primary percutaneous coronary intervention. They were randomly assigned to the treatment group or the control group in a 2:1 ratio. The patients underwent baseline gated single-photon emission computed tomography (G-SPECT) 3-10 days after STEMI with quantitative and qualitative analysis of left ventricular perfusion and systolic function. On the following day, patients from the BMC treatment group were subjected to bone marrow aspiration, mononuclear BMC isolation and intracoronary injection. No placebo procedure was performed in the control group. G-SPECT was repeated 6 months after STEMI. Baseline and follow-up G-SPECT studies were available for 36 patients. At 6 months in the BMC group we observed a significantly enhanced improvement in the mean extent of the perfusion defect, the left ventricular perfusion score index, the infarct area perfusion score and the infarct area wall motion score index compared to the control group (p=0.01-0.04). However, the changes in left ventricular volume, ejection fraction and the left ventricular wall motion score index as well as the relative changes in the infarct area wall motion score index did not differ significantly between the groups. Intracoronary injection of autologous mononuclear BMC in patients with STEMI improves myocardial perfusion at 6 months. The benefit in infarct area systolic function is less pronounced and there is no apparent improvement of global left ventricular systolic function. (orig.)

  13. MR image analysis: Longitudinal cardiac motion influences left ventricular measurements

    International Nuclear Information System (INIS)

    Berkovic, Patrick; Hemmink, Maarten; Parizel, Paul M.; Vrints, Christiaan J.; Paelinck, Bernard P.

    2010-01-01

    Background: Software for the analysis of left ventricular (LV) volumes and mass using border detection in short-axis images only, is hampered by through-plane cardiac motion. Therefore we aimed to evaluate software that involves longitudinal cardiac motion. Methods: Twenty-three consecutive patients underwent 1.5-Tesla cine magnetic resonance (MR) imaging of the entire heart in the long-axis and short-axis orientation with breath-hold steady-state free precession imaging. Offline analysis was performed using software that uses short-axis images (Medis MASS) and software that includes two-chamber and four-chamber images to involve longitudinal LV expansion and shortening (CAAS-MRV). Intraobserver and interobserver reproducibility was assessed by using Bland-Altman analysis. Results: Compared with MASS software, CAAS-MRV resulted in significantly smaller end-diastolic (156 ± 48 ml versus 167 ± 52 ml, p = 0.001) and end-systolic LV volumes (79 ± 48 ml versus 94 ± 52 ml, p < 0.001). In addition, CAAS-MRV resulted in higher LV ejection fraction (52 ± 14% versus 46 ± 13%, p < 0.001) and calculated LV mass (154 ± 52 g versus 142 ± 52 g, p = 0.004). Intraobserver and interobserver limits of agreement were similar for both methods. Conclusion: MR analysis of LV volumes and mass involving long-axis LV motion is a highly reproducible method, resulting in smaller LV volumes, higher ejection fraction and calculated LV mass.

  14. Beat-to-beat evaluation of left ventricular ejection in cardiac arrhythmias

    International Nuclear Information System (INIS)

    Itti, R.; Philippe, L.; Lorgeron, J.M.

    1982-01-01

    Conventional multi-gated cardiac blood pool studies suffer from two kinds of superimpositions: the spatial overlapping of various heart chambers and the temporal superimposition of a large number of cardiac cycles. The first problem can be partially solved by first pass techniques or by emission tomography. For the second one, which is specially critical arrhythmias, the single probe device (''nuclear stethoscope'') represents an original solution. Patients with normal cardiac rythm and patients presenting various kinds of cardiac rythm alterations were examined using a commercial ''nuclear stethoscope''. Some characteristic results achieved in these cases, were presented. For blood pool labeling, 20 mCi of 99mTc albumin was injected. The single probe detector was then positioned over the left ventricular area. The beat-to-beat left ventricular activity curve was then recorded for several minutes on paper in the same time as the E.C.G. signal. In cases with irregular cardiac rythm, the multigated techniques yield an average value of left ventricular ejection. Due to the relatively constant duration of systole, the superimposition of cycles may be valid during contration: differences mainly appear during diastole. But, as it could be demonstrated using the ''nuclear stethoscope'', individual cycles can show a large variability of ejection and average ejection fraction is only a very partial aspect of the real cardiac function

  15. Potential of right to left ventricular volume ratio measured on chest CT for the prediction of pulmonary hypertension: correlation with pulmonary arterial systolic pressure estimated by echocardiography

    International Nuclear Information System (INIS)

    Lee, Heon; Kim, Seok Yeon; Lee, Soo Jeong; Kim, Jae Kyun; Reddy, Ryan P.; Schoepf, U.J.

    2012-01-01

    To investigate the correlation of right ventricular (RV) to left ventricular (LV) volume ratio measured by chest CT with pulmonary arterial systolic pressure (PASP) estimated by echocardiography. 104 patients (72.47 ± 13.64 years; 39 male) who had undergone chest CT and echocardiography were divided into two groups (hypertensive and normotensive) based upon an echocardiography-derived PASP of 25 mmHg. RV to LV volume ratios (RV V /LV V ) were calculated. RV V /LV V was then correlated with PASP using regression analysis. The Area Under the Curve (AUC) for predicting pulmonary hypertension on chest CT was calculated. In the hypertensive group, the mean PASP was 46.29 ± 14.42 mmHg (29-98 mmHg) and there was strong correlation between the RV V /LV V and PASP (R = 0.82, p V /LV V were 0.990 and 0.892. RV V /LV V was 1.01 ± 0.44 (0.51-2.77) in the hypertensive and 0.72 ± 0.14 (0.52-1.11) in the normotensive group (P V /LV V , sensitivity and specificity for predicting pulmonary hypertension over 40 mmHg were 79.5 % and 90 %, respectively. The AUC for predicting pulmonary hypertension was 0.87 RV/LV volume ratios on chest CT correlate well with PASP estimated by echocardiography and can be used to predict pulmonary hypertension over 40 mmHg with high sensitivity and specificity. (orig.)

  16. Left ventricular beat-to-beat performance in atrial fibrillation: Contribution of Frank-Starling mechanism after short rather than long intervals

    NARCIS (Netherlands)

    Gosselink, A.T.M.; Blanksma, P.K.; Crijns, H.J.G.M.; Gelder, I.C. van; Kam, P.J. de; Hillege, H.L.; Niemeijer, M.G.; Lie, K.I.; Meijler, F.L.

    1995-01-01

    This study sought to evaluate control mechanisms of the varying left ventricular performance in atrial fibrillation. Atrial fibrillation is characterized by a randomly irregular ventricular response, resulting in continuous variation in left ventricular beat-to-beat mechanical behavior and

  17. ST depression and left ventricular haemodynamics during exercise in patients with angina pectoris.

    Science.gov (United States)

    Carlens, P; Holmgren, A; Jonasson, R; Landou, C; Orinius, E

    1983-01-01

    The mechanism of ischaemic ST depression and the cause of its low sensitivity to coronary artery stenosis are not well understood. Of 30 patients with severe stable effort angina, 19 (63%) showed ischaemic ST depressions after exercise (the STAE group) and 11 did not. The highest load during the symptom-limited exercise test and the heart rate on that load did not differ between the two groups. The clinical characteristics and angiographic findings were also similar, but the findings at heart catheterization differed during exercise (in supine). Although the load was similar, the stroke index was significantly lower (38 vs. 53 ml/m2 BSA) and the left ventricular end-diastolic pressure rose to a significantly higher value in the STAE group (40 vs. 32 mmHg). When STAE occurred, they were exclusively or concomitantly present in chest lead 5. These findings suggest that ischaemic STAE may not reflect regional ischaemia but the consequent left ventricular dysfunction. The mechanism may, for example, be that a sufficiently elevated left ventricular diastolic pressure causes a global subendocardial ischaemia.

  18. Improved left ventricular function and perfusion at rest after successful transluminal coronary angioplasty

    International Nuclear Information System (INIS)

    Klepzig, H.; Kaltenbach, M.; Standke, R.; Maul, F.D.; Hoer, G.

    1991-01-01

    The purpose of this study was to evaluate left ventricular function and perfusion at rest before and after percutaneous transluminal coronary angioplasty. In consecutive 69 patients in whom coronary stenoses were dilated, the radionuclide left ventricular ejection fraction at rest increased significantly. In 26 of these patients, the ejection fraction increased by at least 4%. In these patients, exercise-induced ischemic ST depression had been more pronounced than in the others. 36 other patients underwent 201 Tl myocardial scintigraphy before and after angioplasty. Twelve patients in whom pre-PTCA images had revealed regions with irreversible 201 Tl uptake defects, showed normal 201 Tl distribution patterns on post-PTCA scintigrams. Post-exercise 201 Tl uptake (representing myocardial perfusion and metabolic activity) during pre-PTCA exercise stress tests was significantly lower in these cases. It is concluded that PTCA can improve left ventricular function and perfusion at rest. This improvement is most obvious in patients with pronounced exercise-induced myocardial ischemia as diagnosed by typical ST segment depression and reduced thallium uptake. (orig.) [de

  19. [Long-term effects of hydroxychloroquine on metabolism of serum lipids and left ventricular structure and function in patients of systemic lupus erythematosus].

    Science.gov (United States)

    Meng, Juan; Lu, Yuewu; Dong, Xin; Liu, Hongyan

    2014-04-08

    To observe the long-term effects of hydroxychloroquine treatment on blood lipids and left ventricular function of systemic lupus erythematosus (SLE) patients. A total of 72 SLE patients were randomly divided into 2 groups of hydroxychloroquine treatment (n = 36) and non-hydroxychloroquine (n = 36). The serum level of lipids, left ventricular end-diastolic diameter (LVEDD), left ventricular end-systolic diameter (LVESD), interventricular septum thickness (IVST), left ventricular posterior wall thickness (LVPWT), fractional shortening rate (FS), left ventricular ejection fraction (LVEF) and E/A ratio were measured before, 6 month, 12 month and 2 years after treatment. After long-term use of hydroxychloroquine, there were statistically differences in the levels of total cholesterol (TC), triglyceride (TG), low-density lipoprotein (LDL) and high-density lipoprotein (HDL). And LVEDD, LVWPT and E/A were statistically different (P lipid metabolism and left ventricular function in SLE patients.

  20. Left ventricular systolic dysfunction after transcatheter closure of a large patent ductus arteriosus.

    Science.gov (United States)

    Galal, Mohammed Omar; Arfi, Muhammed Amin; Nicole, Sekarski; Payot, Maurice; Hussain, Arif; Qureshi, Shakeel

    2005-11-01

    A 12-year-old boy reported in outpatient department with history of shortness of breath and dyspnoea on moderate exertion. Physical examination was significant for bounding pulses and for a continuous murmur III/VI, best heard at the left upper sternal border. Echocardiography confirmed a large patent arterial duct with shortening fraction of 33%. He underwent successful transcatheter closure of the patent arterial, using Amplatzer duct occluder 12/10. Few hours later echocardiography revealed an unexpected, yet important depression of left ventricular systolic function with shortening fraction decreasing to 24% and then two weeks later decreasing further to 20%. At a follow-up after four months, he had improved clinically but left ventricular dysfunction still persisted with shortening fraction of 24%.

  1. Evaluation of ECG criteria for left ventricular hypertrophy before and after aortic valve replacement using magnetic resonance Imaging

    NARCIS (Netherlands)

    Beyerbacht, Hugo P.; Bax, Jeroen J.; Lamb, Hildo J.; van der Laarse, Arnoud; Vliegen, Hubert W.; de Roos, Albert; Zwinderman, Aeilko H.; van der Wall, Ernst E.

    2003-01-01

    PURPOSE: Evaluation of different electrocardiographic criteria for left ventricular hypertrophy (ECG-LVH criteria) using left ventricular mass index (LVMI) determined by magnetic resonance imaging (MRI). In addition, the relation between LVMI regression after aortic valve replacement and

  2. Novel nonsurgical left ventricular assist device and system.

    Science.gov (United States)

    Misiri, Juna; DeSimone, Christopher V; Park, Soon J; Kushwaha, Sudhir S; Friedman, Paul A; Bruce, Charles J; Asirvatham, Samuel J

    2013-01-01

    Treatment options for advanced stages of congestive heart failure remain limited. Left ventricular assist devices (LVADs) have emerged as a means to support failing circulation. However, these devices are not without significant risk such as major open chest surgery. We utilized a novel approach for device placement at the aorto-left atria continuity as a site to create a conduit capable of accommodating a percutaneous LVAD system. We designed and developed an expandable nitinol based device for placement at this site to create a shunt between the LA and aorta. Our experiments support this anatomic location as an accessible and feasible site for accommodation of an entirely percutaneous LVAD. The novelty of this approach would bypass the left ventricle, and thereby minimize complications and morbidities associated with current LVAD placement. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Left Ventricular Myocardial Function in Children With Pulmonary Hypertension: Relation to Right Ventricular Performance and Hemodynamics.

    Science.gov (United States)

    Burkett, Dale A; Slorach, Cameron; Patel, Sonali S; Redington, Andrew N; Ivy, D Dunbar; Mertens, Luc; Younoszai, Adel K; Friedberg, Mark K

    2015-08-01

    Through ventricular interdependence, pulmonary hypertension (PH) induces left ventricular (LV) dysfunction. We hypothesized that LV strain/strain rate, surrogate measures of myocardial contractility, are reduced in pediatric PH and relate to invasive hemodynamics, right ventricular strain, and functional measures of PH. At 2 institutions, echocardiography was prospectively performed in 54 pediatric PH patients during cardiac catheterization, and in 54 matched controls. Patients with PH had reduced LV global longitudinal strain (LS; -18.8 [-17.3 to -20.4]% versus -20.2 [-19.0 to -20.9]%; P=0.0046) predominantly because of reduced basal (-12.9 [-10.8 to -16.3]% versus -17.9 [-14.5 to -20.7]%; Pright ventricular free-wall LS (r=0.64; PBrain natriuretic peptide levels correlated moderately with septal LS (r=0.48; P=0.0038). PH functional class correlated moderately with LV free-wall LS (r=-0.48; P=0.0051). The septum, shared between ventricles and affected by septal shift, was the most affected LV region in PH. Pediatric PH patients demonstrate reduced LV strain/strain rate, predominantly within the septum, with relationships to invasive hemodynamics, right ventricular strain, and functional PH measures. © 2015 American Heart Association, Inc.

  4. Left ventricular synchrony assessed by phase analysis of gated myocardial perfusion SPECT imaging in healthy subjects

    International Nuclear Information System (INIS)

    Wang Yuetao; Wang Jianfeng; Yang Minfu; Niu Rong

    2013-01-01

    Objective: To investigate the value of Cedars-Sinai quantitative gated SPECT (QGS) phase analysis for left ventricular synchrony assessment in healthy subjects. Methods: Seventy-four healthy subjects (41 males, 33 females,average age: (60±13) years) underwent both rest and exercise 99 Tc m -MIBI G-MPI. QGS software was used to analyze the reconstructed rest gated SPECT images automatically, and then the parameters of left ventricular synchrony including phase bandwidth (BW) and phase standard deviation (SD) were obtained. The influences of gender and age (age<60 years, n=36; age ≥ 60 years, n=38) on left ventricular systolic synchronicity were analyzed. The phase angle for original segmental contraction was measured to determine the onset of the ventricular contraction using 17-segment model. Forty healthy subjects were selected by simple random sampling method to evaluate the intra-observer and interobserver repeatability of QGS phase analysis software. Two-sample t test and linear correlation analysis were used to analyze the data. Results: The BW and SD of left ventricular in healthy subjects were (37.22 ±11.71)°, (11.84±5.39)° respectively. Comparisons between male and female for BW and SD yielded no statistical significance (BW: (36.00±9.70)°, (38.73±13.84)°; SD: (11.88±5.56)°, (11.79±5.26)°; t=0.96 and-0.07, both P>0.05); whereas the older subjects (age≥60 years) had larger BW than the others (age<60 years ; (39.95± 12.65)°, (34.33± 10.00)°; t=-2.11, P<0.05) and no statistical significance was shown for SD between the two age groups ((11.18±4.31)°, (12.54±6.33)°; t=1.08, P>0.05). Of the 74 subjects, the mechanical activation started from the ventricular base to apex in 54 subjects (73%), and from apex to base in only 20 subjects (27%). High repeatability of phase analysis was observed for both intra-observer and inter-observer (r=0.867-0.906, all P<0.001). Conclusions: Good left ventricular segmental synchrony is shown in healthy

  5. Quantitative assessment of regional left ventricular motion using endocardial landmarks

    NARCIS (Netherlands)

    C.J. Slager (Cornelis); T.E.H. Hooghoudt (Ton); P.W.J.C. Serruys (Patrick); J.C.H. Schuurbiers (Johan); J.H.C. Reiber (Johan); G.T. Meester (Geert); P.D. Verdouw (Pieter); P.G. Hugenholtz (Paul)

    1986-01-01

    textabstractIn this study the hypothesis is tested that the motion pattern of small anatomic landmarks, recognizable at the left ventricular endocardial border in the contrast angiocardiogram, reflects the motion of the endocardial wall. To verify this, minute metal markers were inserted in the

  6. The effect of right ventricular pacing on myocardial oxidative metabolism and efficiency: relation with left ventricular dyssynchrony

    Energy Technology Data Exchange (ETDEWEB)

    Ukkonen, Heikki; Saraste, Antti; Koistinen, Juhani [Turku University Hospital, Department of Medicine, P.O. Box 52, Turku (Finland); Tops, Laurens; Bax, Jeroen [Leiden University Medical Center, Leiden (Netherlands); Naum, Alexander [University of Turku, Turku PET Centre, Turku (Finland); Knuuti, Juhani [University of Turku, Turku PET Centre, Turku (Finland); Turku University Hospital, Turku PET Centre, P.O. Box 52, Turku (Finland)

    2009-12-15

    Right ventricular (RV) apical pacing induces dyssynchrony by a left bundle branch block type electrical activation sequence in the heart and may impair left ventricular (LV) function. Whether these functional changes are accompanied by changes in myocardial perfusion, oxidative metabolism and efficiency, and the relation with the induction of LV dyssynchrony are unknown. Our study was designed to investigate the acute effects of RV pacing on these parameters. Ten patients with normal LV ejection fraction and VVI/DDD pacemaker were studied during AAI pacing/sinus rhythm without RV pacing (pacing-OFF) and with RV pacing (pacing-ON) at the same heart rate. Dynamic [{sup 15}O]water and [{sup 11}C]acetate positron emission tomography was used to measure perfusion and oxidative metabolism (k{sub mono}) of the LV. An echocardiographic examination was used to assess LV stroke volume (SV) and LV dyssynchrony. Myocardial efficiency of forward work was calculated as systolic blood pressure x cardiac output/LV mass/k{sub mono}. RV pacing decreased SV in all subjects (mean decrease 13%, from 76 {+-} 7 to 66 {+-} 7 ml, p = 0.004), but global perfusion and k{sub mono} were unchanged. The efficiency tended to be lower with pacing-ON (70 {+-} 20 vs 81 {+-} 21 mmHg l/g, p = 0.066). In patients with dyssynchrony during pacing (n = 6) efficiency decreased by 23% (from 78 {+-} 25 to 60 {+-} 14 mmHg l/g, p = 0.02), but in patients without dyssynchrony no change in efficiency was detected. Accordingly, heterogeneity in myocardial perfusion and oxidative metabolism was detected during pacing in patients with dyssynchrony but not in those without dyssynchrony. RV pacing resulted in a significant decrease in SV. However, deleterious effects on LV oxidative metabolism and efficiency were observed only in patients with dyssynchrony during RV pacing. (orig.)

  7. Magnetic resonance tissue phase mapping demonstrates altered left ventricular diastolic function in children with chronic kidney disease

    International Nuclear Information System (INIS)

    Gimpel, Charlotte; Pohl, Martin; Jung, Bernd A.; Jung, Sabine; Brado, Johannes; Odening, Katja E.; Schwendinger, Daniel; Burkhardt, Barbara; Geiger, Julia; Arnold, Raoul

    2017-01-01

    Echocardiographic examinations have revealed functional cardiac abnormalities in children with chronic kidney disease. To assess the feasibility of MRI tissue phase mapping in children and to assess regional left ventricular wall movements in children with chronic kidney disease. Twenty pediatric patients with chronic kidney disease (before or after renal transplantation) and 12 healthy controls underwent tissue phase mapping (TPM) to quantify regional left ventricular function through myocardial long (Vz) and short-axis (Vr) velocities at all 3 levels of the left ventricle. Patients and controls (age: 8 years - 20 years) were matched for age, height, weight, gender and heart rate. Patients had higher systolic blood pressure. No patient had left ventricular hypertrophy on MRI or diastolic dysfunction on echocardiography. Fifteen patients underwent tissue Doppler echocardiography, with normal z-scores for mitral early diastolic (V E ), late diastolic (V A ) and peak systolic (V S ) velocities. Throughout all left ventricular levels, peak diastolic Vz and Vr (cm/s) were reduced in patients: Vz base -10.6 ± 1.9 vs. -13.4 ± 2.0 (P < 0.0003), Vz mid -7.8 ± 1.6 vs. -11 ± 1.5 (P < 0.0001), Vz apex -3.8 ± 1.6 vs. -5.3 ± 1.6 (P = 0.01), Vr base -4.2 ± 0.8 vs. -4.9 ± 0.7 (P = 0.01), Vr mid -4.7 ± 0.7 vs. -5.4 ± 0.7 (P = 0.01), Vr apex -4.7 ± 1.4 vs. -5.6 ± 1.1 (P = 0.05). Tissue phase mapping is feasible in children and adolescents. Children with chronic kidney disease show significantly reduced peak diastolic long- and short-axis left ventricular wall velocities, reflecting impaired early diastolic filling. Thus, tissue phase mapping detects chronic kidney disease-related functional myocardial changes before overt left ventricular hypertrophy or echocardiographic diastolic dysfunction occurs. (orig.)

  8. Magnetic resonance imaging of athlete's heart: myocardial mass, left ventricular function, and cross-sectional area of the coronary arteries

    International Nuclear Information System (INIS)

    Zandrino, F.; Sardanelli, F.; Molinari, G.; Masperone, M.A.; Smeraldi, A.; Odaglia, G.

    2000-01-01

    To evaluate left ventricular myocardial mass and function as well as ostial coronary artery cross-sectional area in endurance athletes, an athlete group of 12 highly trained rowers and a control group of 12 sedentary healthy subjects underwent MR examination. An ECG-gated breath-hold cine gradient-echo sequence was used to calculate myocardial mass, end-diastolic and end-systolic volumes, stroke volume, and cardiac output, all related to body surface area, as well as ejection fraction. A 3D fat-saturated ECG- and respiratory-triggered navigator echo sequence was used to evaluate coronary arteries: left main (LM), left anterior descending (LAD), left circumflex (LCx), and right coronary artery (RCA). Cross-sectional area was calculated and divided for body surface area. Myocardial mass was found significantly larger in athlete group than in control group (p = 0.0078), the same being for end-diastolic volume (p = 0.0078), stroke volume (p = 0.0055), LM (p = 0.0066) and LAD (p = 0.0129). No significant difference was found for all the remaining parameters. Significant correlation with myocardial mass was found for LM (p < 0.001) and LAD (p = 0.0340), not for LCx and RCA. Magnetic resonance imaging is a useful tool in evaluating the myocardial hypertrophy and function of athlete's heart. Magnetic resonance angiography is a valuable noninvasive method to visualize the correlated cross-sectional area increase of the left coronary artery system. (orig.)

  9. Left ventricular remodeling and change of systolic function after closure of patent ductus arteriosus in adults: device and surgical closure.

    Science.gov (United States)

    Jeong, Young-Hoon; Yun, Tae-Jin; Song, Jong-Min; Park, Jung-Jun; Seo, Dong-Man; Koh, Jae-Kon; Lee, Se-Whan; Kim, Mi-Jeong; Kang, Duk-Hyun; Song, Jae-Kwan

    2007-09-01

    Left ventricular (LV) remodeling and predictors of LV systolic function late after closure of patent ductus arteriosus (PDA) in adults remain to be clearly demonstrated. In 45 patients with PDA, including 28 patients who received successful occlusion using the Amplatzer device (AD group) (AGA, Golden Valley, MN) and 17 patients who received surgical closure (OP group), echocardiography studies were performed before closure and 1 day (AD group) or within 7 days (OP group) after closure, and then were repeated at > or = 6 months (17 +/- 13 months). In both groups, LV ejection fraction (EF) and end-diastolic volume index were significantly decreased immediately after closure, whereas end-systolic volume index did not change. During the long-term follow-up period, end-systolic as well as end-diastolic volume indices decreased significantly in both groups and LV EF recovered compared to the immediate postclosure state. However, LV EF remained low compared to the preclosure state. Five patients (11.1%) including 3 patients in the AD group and 2 patients in the OP group showed persistent late LV systolic dysfunction (EF or = 62% had a sensitivity of 72% and a specificity of 83% for predicting late normal LV EF after closure. Left ventricular EF remains low late after PDA closure compared with preclosure state in adults. Preclosure LV EF is the best index to predict late postclosure LV EF.

  10. Is right ventricular mid-septal pacing superior to apical pacing in patients with high degree atrio-ventricular block and moderately depressed left ventricular function?

    Science.gov (United States)

    Chen, Kang; Mao, Ye; Liu, Shao-hua; Wu, Qiong; Luo, Qing-zhi; Pan, Wen-qi; Jin, Qi; Zhang, Ning; Ling, Tian-you; Chen, Ying; Gu, Gang; Shen, Wei-feng; Wu, Li-qun

    2014-06-01

    We are aimed to investigate whether right ventricular mid-septal pacing (RVMSP) is superior to conventional right ventricular apical pacing (RVAP) in improving clinical functional capacity and left ventricular ejection fraction (LVEF) for patients with high-degree atrio-ventricular block and moderately depressed left ventricle (LV) function. Ninety-two patients with high-degree atrio-ventricular block and moderately reduced LVEF (ranging from 35% to 50%) were randomly allocated to RVMSP (n=45) and RVAP (n=47). New York Heart Association (NYHA) functional class, echocardiographic LVEF, and distance during a 6-min walk test (6MWT) were determined at 18 months after pacemaker implantation. Serum levels of N-terminal pro-brain natriuretic peptide (NT-proBNP) were measured using an enzyme-linked immunosorbent assay (ELISA) kit. Compared with baseline, NYHA functional class remained unchanged at 18 months, distance during 6MWT (485 m vs. 517 m) and LVEF (36.7% vs. 41.8%) were increased, but BNP levels were reduced (2352 pg/ml vs. 710 pg/ml) in the RVMSP group compared with those in the RVAP group, especially in patients with LVEF 35%-40% (for all comparisons, Pfunction capacity and LV function measurements were not significantly changed in patients with RVAP, despite the pacing measurements being similar in both groups, such as R-wave amplitude and capture threshold. RVMSP provides a better clinical utility, compared with RVAP, in patients with high-degree atrioventricular block and moderately depressed LV function whose LVEF levels ranged from 35% to 40%.

  11. Assessment of left ventricular function: comparison between radionuclide angiography and semiquantitative two-dimensional echocardiographic analysis

    International Nuclear Information System (INIS)

    Gottsauner-Wolf, M.; Schedlmayer-Duit, J.; Porenta, G.; Gwechenberger, M.; Huber, K.; Glogar, D.; Probst, P.; Sochor, H.

    1996-01-01

    Measurement of global left ventricular function is important in the follow-up of cardiac patients and is a good prognostic indicator in acute cardiac situations. We compared quantitative measurements of global left ventricular function made with radionuclide angiography (RNA) and contrast cardiac ventriculography (CVG) to visual semiquantitative estimates from two-dimensional echocardiographic images (2D-echo). Three hundred and thirty-nine consecutive patients who underwent RNA were assessed with 2D-echo within 3 months. In addition, 92 of these patients also underwent CVG (correlation of ejection fraction between CVG and RNA: r=0.82; P<0.0001). The RNA mean ejection fractions in the four 2D-echo groups (0=normal, 1=slightly, 2=moderate, or 3=severe reduced left ventricular function) differed markedly (P<0.0001); however, there was overlapping among the groups (2D-echo score/RNA ejection fraction: 0=57.3%±12.8%; 1=46.0%±12.9%; 2=29.6%± 12.2%; and 3=24.6%±11.5%) and the difference between 2D-echo scores 2 and 3 was not significant. 2D-echo showed a good concordance in RNA classes (0=≥505; 1=35%-49%; 2=21%-34%; and 3=≤20% ejection fraction) 0 (133/166; 80%) and 3 (18/30; 60%) but low concordance in classes 1 (27/82; 33%) and 2 (21/61; 34%). For accurate assessment of global left ventricular ejection fraction, visual semiquantitative judgement of a 2D echocardiographic image is limited in comparison to CVG or RNA, especially in patients with a slight or moderate reduction in left ventricular ejection fraction. (orig.). With 2 figs., 2 tabs

  12. Cardiac MRI in children and adolescents who have undergone surgical repair of right-sided congenital heart disease. Automated left ventricular volumes and function analysis and effects of different manual adjustments

    Energy Technology Data Exchange (ETDEWEB)

    Rompel, O.; Janka, R.; May, M.S.; Lell, M.M.; Uder, M.; Hammon, M. [University Hospital Erlangen (Germany). Dept. of Radiology; Gloeckler, M.; Dittrich, S. [University Hospital Erlangen (Germany). Dept. of Pediatric Cardiology; Cesnjevar, R. [University Hospital Erlangen (Germany). Dept. of Pediatric Cardiac Surgery

    2015-12-15

    To evaluate automated segmentation and the effects of different manual adjustments regarding left ventricular parameter quantification in cardiac magnetic resonance (MR) data on children and adolescents who have undergone surgical repair of right-sided congenital heart disease (CHD). Dedicated software (syngo.via, Siemens AG) was used to automatically segment and/or manually adjust the end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), myocardial mass (MM) and ejection fraction (EF) before/after manual apex/base adjustment (ADJ-step 1) and after manual apex/base/myocardial contour adjustment (ADJ-step 2; reference standard). MR data of 40 patients (13.1 ± 3.1y, 4-17y) with repaired CHD with decreased pulmonary blood flow (CHD-DPBF) were evaluated. Intra- and inter-rater reliability was determined for 10 randomly selected patients. The software correctly detected the left ventricle in 38/40 (95 %) patients. EDV after automated segmentation: 119.1 ± 44.0ml; after ADJ-step 1: 115.8 ± 39.5 ml; after ADJ-step 2: 116.2 ± 39.4 ml. The corresponding results for ESV were 52.0 ± 18.5/49.6 ± 16.9/49.7 ± 16.4 ml; for SV 67.1 ± 28.5/66.2 ± 25.4/66.5 ± 25.5 ml; for EF 55.5 ± 7.3/56.7 ± 6.6/56.7 ± 6.3%; for MM 83.7 ± 35.9/76.2 ± 28.3/74.6 ± 27.2 g. Significant differences were found for ESV/MM/EF comparing the automated segmentation results with these after ADJ-step 1 and ADJ-step 2. No significant differences were found when comparing all results of ADJ-step 1 and ADJ-step 2 or when comparing EDV/SV results. Intra- and inter-rater reliability was excellent. The mean time effort was 63.4 ± 6.9 s for the automated segmentation, 74.2 ± 8.9 s for ADJ-step 1 and 269.5 ± 39.4 s for ADJ-step 2. Automated left ventricular volumes and function analysis in children and adolescents with surgically treated CHD proved to be feasible with excellent intra- and inter-rater reliability. Automated segmentation with manual apex/base adjustment provided

  13. Cardiac MRI in children and adolescents who have undergone surgical repair of right-sided congenital heart disease. Automated left ventricular volumes and function analysis and effects of different manual adjustments

    International Nuclear Information System (INIS)

    Rompel, O.; Janka, R.; May, M.S.; Lell, M.M.; Uder, M.; Hammon, M.; Gloeckler, M.; Dittrich, S.; Cesnjevar, R.

    2015-01-01

    To evaluate automated segmentation and the effects of different manual adjustments regarding left ventricular parameter quantification in cardiac magnetic resonance (MR) data on children and adolescents who have undergone surgical repair of right-sided congenital heart disease (CHD). Dedicated software (syngo.via, Siemens AG) was used to automatically segment and/or manually adjust the end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), myocardial mass (MM) and ejection fraction (EF) before/after manual apex/base adjustment (ADJ-step 1) and after manual apex/base/myocardial contour adjustment (ADJ-step 2; reference standard). MR data of 40 patients (13.1 ± 3.1y, 4-17y) with repaired CHD with decreased pulmonary blood flow (CHD-DPBF) were evaluated. Intra- and inter-rater reliability was determined for 10 randomly selected patients. The software correctly detected the left ventricle in 38/40 (95 %) patients. EDV after automated segmentation: 119.1 ± 44.0ml; after ADJ-step 1: 115.8 ± 39.5 ml; after ADJ-step 2: 116.2 ± 39.4 ml. The corresponding results for ESV were 52.0 ± 18.5/49.6 ± 16.9/49.7 ± 16.4 ml; for SV 67.1 ± 28.5/66.2 ± 25.4/66.5 ± 25.5 ml; for EF 55.5 ± 7.3/56.7 ± 6.6/56.7 ± 6.3%; for MM 83.7 ± 35.9/76.2 ± 28.3/74.6 ± 27.2 g. Significant differences were found for ESV/MM/EF comparing the automated segmentation results with these after ADJ-step 1 and ADJ-step 2. No significant differences were found when comparing all results of ADJ-step 1 and ADJ-step 2 or when comparing EDV/SV results. Intra- and inter-rater reliability was excellent. The mean time effort was 63.4 ± 6.9 s for the automated segmentation, 74.2 ± 8.9 s for ADJ-step 1 and 269.5 ± 39.4 s for ADJ-step 2. Automated left ventricular volumes and function analysis in children and adolescents with surgically treated CHD proved to be feasible with excellent intra- and inter-rater reliability. Automated segmentation with manual apex/base adjustment provided

  14. Tissue doppler echocardiography for evaluating left ventricular functions in obese

    Directory of Open Access Journals (Sweden)

    Mecnun Çetin

    2013-03-01

    Full Text Available Objective: The aim of this study was to investigate theimpact of childhood obesity on ventricular functions usingtissue Doppler echocardiography.Materials and methods: The mitral tissue Doppler signalswere recorded in the apical four-chamber view, with thesample volume placed at the lateral walls of mitral annulus.The mitral flow was examined with the sample Pulse Dopplerpositioned parallely to flow just at the orifice of the mitralleaflets. Twenty obese (mean age, 161.5±25.8 monthsand 20 healthy children (mean age, 151.2±33.5 monthswere included to this study.Results: Body mass index (BMI was significantly higherin obese group (30.92±6.87. Isovolumic relaxation time(IVRT which is one of the left ventricular (LV diastolicfunction parameters was 66.10±7.30 ms in obese group,and 58.70±9.06 ms in the control group. IVRT was significantlyhigher in the obese group (p=0.007. In obesegroup, the mitral annulus tissue Doppler E velocity wasdecreased, flow velocity was increased and decrement inEm/Am ratio was significant. We found significant negativecorrelation between BMI and LV Em/Am ratio. Myocardialperformance index (MPI in obese group and control groupwas 0.50±0.07 and 0.41±0.04, respectively (p<0.001.Between MPI and LV Em/Am ratio there was a significantnegative correlation while MPI showed positive correlationwith BMI. In obese group septal and LV posterior wall thicknesswas shown to be significantly increased compared tothe control group (p<0.001.Conclusion: Our findings, may be important for determinationof the relationship between obesity and cardiovascularrisk factors in children. Tissue Doppler echocardiographicimaging may be useful in revealing this relationship.Key words: obesity, doppler echocardiography, ventricular dysfunction

  15. Left ventricular cardiac myxoma and sudden death in a dog

    NARCIS (Netherlands)

    de Nijs, M.I.; Vink, Aryan; Bergmann, W.; Szatmári, V.

    2016-01-01

    Background: Myxoma is a very rare benign cardiac tumor in dogs. This is the first description of a cardiac myxoma originating from the left ventricular outflow tract, presumably causing sudden death. Case presentation: A previously healthy 12-year-old male West Highland white terrier was found dead

  16. Left ventricular cardiac myxoma and sudden death in a dog

    NARCIS (Netherlands)

    de Nijs, Maria Irene; Vink, Aryan; Bergmann, Wilhelmina; Szatmári, Viktor

    2016-01-01

    BACKGROUND: Myxoma is a very rare benign cardiac tumor in dogs. This is the first description of a cardiac myxoma originating from the left ventricular outflow tract, presumably causing sudden death. CASE PRESENTATION: A previously healthy 12-year-old male West Highland white terrier was found dead

  17. Do diabetes mellitus and systemic hypertension predispose to left ventricular free wall rupture in acute myocardial infarction?

    DEFF Research Database (Denmark)

    Melchior, T; Hildebrant, P; Køber, L

    1997-01-01

    Diabetes and systemic hypertension had no influence on left ventricular free wall rupture complicating acute myocardial infarction. Age <65 years and a history of coronary artery disease offers some protection from protection.......Diabetes and systemic hypertension had no influence on left ventricular free wall rupture complicating acute myocardial infarction. Age

  18. The survival of patients with heart failure with preserved or reduced left ventricular ejection fraction

    DEFF Research Database (Denmark)

    Boesgaard, Søren

    2012-01-01

    A substantial proportion of patients with heart failure have preserved left ventricular ejection fraction (HF-PEF). Previous studies have reported mixed results whether survival is similar to those patients with heart failure and reduced EF (HF-REF).......A substantial proportion of patients with heart failure have preserved left ventricular ejection fraction (HF-PEF). Previous studies have reported mixed results whether survival is similar to those patients with heart failure and reduced EF (HF-REF)....

  19. Calculation of the ALMA Risk of Right Ventricular Failure After Left Ventricular Assist Device Implantation.

    Science.gov (United States)

    Loforte, Antonio; Montalto, Andrea; Musumeci, Francesco; Amarelli, Cristiano; Mariani, Carlo; Polizzi, Vincenzo; Lilla Della Monica, Paola; Grigioni, Francesco; Di Bartolomeo, Roberto; Marinelli, Giuseppe

    2018-05-08

    Right ventricular failure after continuous-flow left ventricular assist device (LVAD) implantation is still an unsolved issue and remains a life-threatening event for patients. We undertook this study to determine predictors of the patients who are candidates for isolated LVAD therapy as opposed to biventricular support (BVAD). We reviewed demographic, echocardiographic, hemodynamic, and laboratory variables for 258 patients who underwent both isolated LVAD implantation and unplanned BVAD because of early right ventricular failure after LVAD insertion, between 2006 and 2017 (LVAD = 170 and BVAD = 88). The final study patients were randomly divided into derivation (79.8%, n = 206) and validation (20.1%, n = 52) cohorts. Fifty-seven preoperative risk factors were compared between patients who were successfully managed with an LVAD and those who required a BVAD. Nineteen variables demonstrated statistical significance on univariable analysis. Multivariable logistic regression analysis identified destination therapy (odds ratio [OR] 2.0 [1.7-3.9], p = 0.003), a pulmonary artery pulsatility index right ventricle/left ventricle end-diastolic diameter ratio >0.75 (OR 2.7 [1.5-5.5], p = 0.001), an right ventricle stroke work index 17 (OR 3.5 [1.9-6.9], p the major predictors of the need for BVAD. Using these data, we propose a simple risk calculator to determine the suitability of patients for isolated LVAD support in the era of continuous-flow mechanical circulatory support devices.

  20. Relationship of left ventricular, elastic and muscular arteries remodeling in patients with uncontrolled arterial hypertension

    Directory of Open Access Journals (Sweden)

    S. Ya. Dotsenko

    2013-04-01

    Full Text Available Introduction. Uncontrolled hypertension is observed in 65-92% of hypertensive patients. It plays an important role in the development of adverse cardiovascular events and survival, which depend on subclinical target organ damage. There are reports on the relationship between ineffective hypertension control and left ventricular (LV hypertrophy or large arteries stiffness. However, the nature of the remodeling in uncontrolled hypertension remains poorly understood. Objective: to study the character and relationship of left ventricular and arterial remodeling depending on effectiveness of hypertension control. Design and method. We performed a study of 363 hypertensive patients (160 men and 203 women aged 50,8 ± 1,2 years without comorbidities, which were divided into 3 groups according to the effectiveness of blood pressure (BP control: 160 patients with controlled hypertension, 142 patients with uncontrolled hypertension and 61 patients with resistant hypertension. Uncontrolled BP based on measured systolic BP≥140 mmHg and diastolic BP≥90 mmHg. Remodeling indexes of left ventricular, elastic (common carotid and muscular (brachial artery were evaluated by the ultrasonic method. The severity and character of diastolic dysfunction, hypertrophy, types of remodeling and stiffness were assessed. Statistical processing of the results was performed using Student's t criterion and Pearson correlation analysis. Results and discussion. According to the results of the study, uncontrolled hypertension affected the development of subclinical cardiovascular lesions negatively. Thus, LV hypertrophy was detected more frequently in the third group (91,8% in resistant hypertension versus 46,8% in controlled hypertension, p<0,05. Differences in LV geometry with increasing of concentric remodeling types were also observed more frequently in the third group, where concentric remodeling and concentric hypertrophy types were founded in 14,8% and 59