WorldWideScience

Sample records for left axis deviation

  1. Clinical and Financial Impact of Ordering an Echocardiogram in Children with Left Axis Deviation on Their Electrocardiogram.

    Science.gov (United States)

    Ravi, Prasad; Ashwath, Ravi; Strainic, James; Li, Hong; Steinberg, Jon; Snyder, Christopher

    2016-01-01

    Left axis deviation (LAD) on the electrocardiogram (ECG) is associated with congenital heart disease (CHD), prompting the clinician to order further testing when evaluating a patient with this finding. The purpose is to (1) compare the physical examination (PE) by a pediatric cardiologist to echocardiogram (ECHO) findings in patients with LAD on resting ECG and (2) assess cost of performing ECHO on all patients with LAD on ECG. An IRB approved, retrospective cohort study was performed on patients with LAD (QRS axis ≥0° to -90°) on ECG between 01/02 and 12/12. age >0.25 and <18 years, non-postoperative, and PE and ECHO by pediatric cardiologist. A decision tree model analyzed cost of ECHO in patients with LAD and normal/abnormal PE. Cost of complete ECHO ($239.00) was obtained from 2014 Medicare reimbursement rates. A total of 146 patients met inclusion criteria with 46.5% (68) having normal PE and ECHO, 1.4% (2) having normal PE and abnormal ECHO, 47.3% (69) having abnormal PE and ECHO, and 4.8% (7) having an abnormal PE and normal ECHO. Sensitivity and specificity of PE for detecting abnormalities in this population was 97% and 90%. Positive and negative predictive value of PE was 91% and 97.5%. In patients with normal PE, the cost to identify an ECHO abnormality was $8365, and $263 for those with abnormal PE. In presence of LAD on ECG, the sensitivity, specificity, and positive and negative predictive values of PE by a pediatric cardiologist are excellent at identifying CHD. Performing an ECHO on patients with LAD on ECG is only cost effective in the presence of an abnormal PE. In the presence of normal PE, there is a possibility of missing incidental structural cardiac disease in approximately 2% if an ECHO is not performed. © 2015 Wiley Periodicals, Inc.

  2. Left-Deviating Prism Adaptation in Left Neglect Patient: Reflexions on a Negative Result

    Directory of Open Access Journals (Sweden)

    Jacques Luauté

    2012-01-01

    Full Text Available Adaptation to right-deviating prisms is a promising intervention for the rehabilitation of patients with left spatial neglect. In order to test the lateral specificity of prism adaptation on left neglect, the present study evaluated the effect of left-deviating prism on straight-ahead pointing movements and on several classical neuropsychological tests in a group of five right brain-damaged patients with left spatial neglect. A group of healthy subjects was also included for comparison purposes. After a single session of exposing simple manual pointing to left-deviating prisms, contrary to healthy controls, none of the patients showed a reliable change of the straight-ahead pointing movement in the dark. No significant modification of attentional paper-and-pencil tasks was either observed immediately or 2 hours after prism adaptation. These results suggest that the therapeutic effect of prism adaptation on left spatial neglect relies on a specific lateralized mechanism. Evidence for a directional effect for prism adaptation both in terms of the side of the visuomanual adaptation and therefore possibly in terms of the side of brain affected by the stimulation is discussed.

  3. Automatic short axis orientation of the left ventricle in 3D ultrasound recordings

    Science.gov (United States)

    Pedrosa, João.; Heyde, Brecht; Heeren, Laurens; Engvall, Jan; Zamorano, Jose; Papachristidis, Alexandros; Edvardsen, Thor; Claus, Piet; D'hooge, Jan

    2016-04-01

    The recent advent of three-dimensional echocardiography has led to an increased interest from the scientific community in left ventricle segmentation frameworks for cardiac volume and function assessment. An automatic orientation of the segmented left ventricular mesh is an important step to obtain a point-to-point correspondence between the mesh and the cardiac anatomy. Furthermore, this would allow for an automatic division of the left ventricle into the standard 17 segments and, thus, fully automatic per-segment analysis, e.g. regional strain assessment. In this work, a method for fully automatic short axis orientation of the segmented left ventricle is presented. The proposed framework aims at detecting the inferior right ventricular insertion point. 211 three-dimensional echocardiographic images were used to validate this framework by comparison to manual annotation of the inferior right ventricular insertion point. A mean unsigned error of 8, 05° +/- 18, 50° was found, whereas the mean signed error was 1, 09°. Large deviations between the manual and automatic annotations (> 30°) only occurred in 3, 79% of cases. The average computation time was 666ms in a non-optimized MATLAB environment, which potentiates real-time application. In conclusion, a successful automatic real-time method for orientation of the segmented left ventricle is proposed.

  4. Earlier Right Ventricular Pacing in Cardiac Resynchronization Therapy for a Patient with Right Axis Deviation.

    Science.gov (United States)

    Hattori, Yusuke; Ishibashi, Kohei; Noda, Takashi; Okamura, Hideo; Kanzaki, Hideaki; Anzai, Toshihisa; Yasuda, Satoshi; Kusano, Kengo

    2017-09-01

    We describe the case of a 37-year-old woman who presented with complete right bundle branch block and right axis deviation. She was admitted to our hospital due to severe heart failure and was dependent on inotropic agents. Cardiac resynchronization therapy was initiated but did not improve her condition. After the optimization of the pacing timing, we performed earlier right ventricular pacing, which led to an improvement of her heart failure. Earlier right ventricular pacing should be considered in patients with complete right bundle branch block and right axis deviation when cardiac resynchronization therapy is not effective.

  5. Left ventricular aneurysm in short axis: a comparison of magnetic resonance, ultrasound and thallium-201 SPECT images

    International Nuclear Information System (INIS)

    Ahmad, M.; Johnson, R.F. Jr.; Fawcett, H.D.; Schreiber, M.H.

    1987-01-01

    Short axis magnetic resonance images of a left ventricular aneurysm were compared to similar views obtained by echocardiography and by thallium-201 single photon emission computed tomography. Images of the dyskinetic left ventricular apex and the contractile left ventricular base were analyzed and compared. Unlike the previously reported orthogonal plane magnetic resonance images, short axis imaging provided representative and quantitative information in views comparable to those obtained by standard noninvasive imaging techniques. These data indicate that short axis magnetic resonance imaging is capable of identifying and sizing the aneurysmal and the residual segments of the left ventricle. The findings may be of prognostic value in patients with left ventricular aneurysm

  6. Measurement and analysis of the thoracic patient setup deviations in routine radiotherapy

    International Nuclear Information System (INIS)

    Jia Mingxuan; Zou Huawei; Wu Rong; Sun Jian; Dong Xiaoqi

    2003-01-01

    Objective: To determine the magnitude of the setup deviations of the thoracic patients in routine radiotherapy. Methods: Altogether 408 films for 21 thoracic patients were recorded using the electronic portal imaging device (EPID), and comparison with reference CT simulator digitally-reconstructed radiograph (DRR) for anterior-posterior fields was performed. The deviation of setup for 21 patients in the left-right (RL), superior-inferior (SI) directions and rotation about the anterior-posterior (AP) axis were measured and analyzed. Results: Without immobilization device, the mean translational and rotational setup deviations were (0.7±3.1) mm and (1.5±4.1) mm in the RL and SI directions, respectively, and (0.3±2.4) degree about AP axis. With immobilization device, the mean translational and rotational setup deviations were (0.5±2.4) mm and (0.8±2.7) mm in the RL and SI directions respectively, and (0.2±1.6) degree about AP axis. Conclusion: The setup deviations in thoracic patients irradiation may be reduced with the use of the immobilization device. The setup deviation in the SI direction is greater than that in the RL direction. The setup deviations are mainly random errors

  7. Shaping the zebrafish heart: from left-right axis specification to epithelial tissue morphogenesis.

    NARCIS (Netherlands)

    Bakkers, J.; Verhoeven, M.C.; Abdelilah-Seyfried, S.

    2009-01-01

    Although vertebrates appear bilaterally symmetric on the outside, various internal organs, including the heart, are asymmetric with respect to their position and/or their orientation based on the left/right (L/R) axis. The L/R axis is determined during embryo development. Determination of the L/R

  8. Phase image characterization of ventricular contraction in left anterior hemiblock

    International Nuclear Information System (INIS)

    Ono, Akifumi; Mizuno, Haruyoshi; Tahara, Yorio; Ishikawa, Kyozo

    1991-01-01

    We investigated whether or not left anterior hemiblock is present in patients with left axis deviation using first-harmonic Fourier analysis of gated blood-pool images. Gated blood-pool images were taken in 50 patients without contraction abnormality. They included 14 normal subjects, 8 patients with right bundle branch block (RBBB), 20 with left axis deviation (LAD) and 8 with both RBBB and LAD (RBBB+LAD). ECG gated blood-pool scans were acquired in the anterior and 'best septal' left anterior oblique projections. First, the phase images were displayed cinematically as a continuous-loop movie. Next, for quantitative analysis of the phase image, the whole left ventricular and left ventricular high lateral regions of interest were drawn. The 'regional phase shift' (RPS) was then defined as {RPS=A-a} where 'A' is the mean value of the whole left ventricular phase angles and 'a' is that of phase angles in the high lateral region. The left ventricular phase changes and the RPSs in the RBBB and LAD groups were similar to those in the normal group. In the RBBB+LAD group, the latest phase changes occurred in the high anterolateral region. The RPSs of this group were significantly lower than those in the other 3 groups (p<0.01). These data suggest that left anterior hemiblock might coexist with RBBB in patients with RBBB+LAD, whereas left anterior hemiblock might not exist in the majority of patients with LAD alone. (author)

  9. Deviating colostomy construction versus stent placement as bridge to surgery for malignant left-sided colonic obstruction

    NARCIS (Netherlands)

    Amelung, F.J.; Borg, F. ter; Consten, E.C.; Siersema, P.D.; Draaisma, W.A.

    2016-01-01

    BACKGROUND: Acute colonic decompression using a deviating colostomy (DC) or a self-expandable metal stent (SEMS) has been shown to lead to fewer complications and permanent stomas compared to acute resection in elderly patients with malignant left-sided colonic obstruction (LSCO). However, no

  10. Development of automatic extraction method of left ventricular contours on long axis view MR cine images

    International Nuclear Information System (INIS)

    Utsunomiya, Shinichi; Iijima, Naoto; Yamasaki, Kazunari; Fujita, Akinori

    1995-01-01

    In the MRI cardiac function analysis, left ventricular volume curves and diagnosis parameters are obtained by extracting the left ventricular cavities as regions of interest (ROI) from long axis view MR cine images. The ROI extractions had to be done by manual operations, because automatization of the extraction is difficult. A long axis view left ventricular contour consists of a cardiac wall part and an aortic valve part. The above mentioned difficulty is due to the decline of contrast on the cardiac wall part, and the disappearance of edge on the aortic valve part. In this paper, we report a new automatic extraction method for long axis view MR cine images, which needs only 3 manually indicated points on the 1st image to extract all the contours from the total sequence of images. At first, candidate points of a contour are detected by edge detection. Then, selecting the best matched combination of candidate points by Dynamic Programming, the cardiac wall part is automatically extracted. The aortic valve part is manually extracted for the 1st image by indicating both the end points, and is automatically extracted for the rest of the images, by utilizing the aortic valve motion characteristics throughout a cardiac cycle. (author)

  11. Automatic localization of the left ventricular blood pool centroid in short axis cardiac cine MR images.

    Science.gov (United States)

    Tan, Li Kuo; Liew, Yih Miin; Lim, Einly; Abdul Aziz, Yang Faridah; Chee, Kok Han; McLaughlin, Robert A

    2018-06-01

    In this paper, we develop and validate an open source, fully automatic algorithm to localize the left ventricular (LV) blood pool centroid in short axis cardiac cine MR images, enabling follow-on automated LV segmentation algorithms. The algorithm comprises four steps: (i) quantify motion to determine an initial region of interest surrounding the heart, (ii) identify potential 2D objects of interest using an intensity-based segmentation, (iii) assess contraction/expansion, circularity, and proximity to lung tissue to score all objects of interest in terms of their likelihood of constituting part of the LV, and (iv) aggregate the objects into connected groups and construct the final LV blood pool volume and centroid. This algorithm was tested against 1140 datasets from the Kaggle Second Annual Data Science Bowl, as well as 45 datasets from the STACOM 2009 Cardiac MR Left Ventricle Segmentation Challenge. Correct LV localization was confirmed in 97.3% of the datasets. The mean absolute error between the gold standard and localization centroids was 2.8 to 4.7 mm, or 12 to 22% of the average endocardial radius. Graphical abstract Fully automated localization of the left ventricular blood pool in short axis cardiac cine MR images.

  12. An Overview of Techniques for Cardiac Left Ventricle Segmentation on Short-Axis MRI

    Directory of Open Access Journals (Sweden)

    Krasnobaev Arseny

    2016-01-01

    Full Text Available Nowadays, heart diseases are the leading cause of death. Left ventricle segmentation of a human heart in magnetic resonance images (MRI is a crucial step in both cardiac diseases diagnostics and heart internal structure reconstruction. It allows estimating such important parameters as ejection faction, left ventricle myocardium mass, stroke volume, etc. In addition, left ventricle segmentation helps to construct the personalized heart computational models in order to conduct the numerical simulations. At present, the fully automated cardiac segmentation methods still do not meet the accuracy requirements. We present an overview of left ventricle segmentation algorithms on short-axis MRI. A wide variety of completely different approaches are used for cardiac segmentation, including machine learning, graph-based methods, deformable models, and low-level heuristics. The current state-of-the-art technique is a combination of deformable models with advanced machine learning methods, such as deep learning or Markov random fields. We expect that approaches based on deep belief networks are the most promising ones because the main training process of networks with this architecture can be performed on the unlabelled data. In order to improve the quality of left ventricle segmentation algorithms, we need more datasets with labelled cardiac MRI data in open access.

  13. Congenital axis dysmorphism in a medieval skeleton : …secunda a vertendo epistropheus….

    Science.gov (United States)

    Travan, Luciana; Saccheri, Paola; Toso, Francesco; Crivellato, Enrico

    2013-05-01

    We describe here the axis dysmorphism that we observed in the skeletal remains of a human child dug up from a fifteenth century cemetery located in north-eastern Italy. This bone defect is discussed in the light of pertinent literature. We performed macroscopical examination and CT scan analysis of the axis. Axis structure was remarkably asymmetric. Whilst the left half exhibited normal morphology, the right one was smaller than normal, and its lateral articular surface showed horizontal orientation. In addition, the odontoid process appeared leftward deviated and displayed a supplementary articular-like facet situated on the right side of its surface. These findings suggest a diagnosis of unilateral irregular segmentation of atlas and axis, a rare dysmorphism dependent upon disturbances of notochordal development in early embryonic life. Likewise other malformations of the craniovertebral junction, this axis defect may alter the delicate mechanisms of upper neck movements and cause a complex series of clinical symptoms. This is an emblematic case whereby human skeletal remains may provide valuable information on the anatomical defects of craniovertebral junction.

  14. Evaluation of left ventricular ejection fraction from radial long-axis tomography. A new reconstruction algorithm for ECG-gated technetium-99m Sestamibi SPECT

    International Nuclear Information System (INIS)

    Tsujimura, Eiichiro; Kusuoka, Hideo; Uehara, Toshiisa

    1997-01-01

    Radial long-axis tomography can provide views similar to contrast left ventriculography (LVG) including the basal and apical areas of the left ventricle, not possible in routine short-axis tomography. We applied this method to ECG-gated Tc-99m Sestamibi (MIBI) myocardial SPECT images to estimate the left ventricular ejection fraction (LVEF). ECG-gated Tc-99m MIBI SPECT was performed with a temporal resolution of 10 frames per R-R interval. LVEF was calculated on the basis of left ventricular volume estimates at end diastole (ED) and end systole (ES) with using an ellipsoid body model. To validate this method, LVEF's derived from ECG-gated Tc-99m MIBI SPECT were compared with those from LVG in 11 patients with coronary artery disease. There was a close linear correlation between LVEF values calculated from Tc-99m MIBI SPECT and those from LVG (r=0.89, p<0.001), although the gated SPECT underestimated LVEF compared to LVG. The technique showed excellent reproducibility (intra-observer variability, r=0.96, p<0.001; inter-observer variability, r=0.71, p<0.005). The radial long-axis tomography technique gives a good estimate of LVEF, in agreement with estimates based on LVG. ECG-gated Tc-99m MIBI SPECT can, therefore, be applicable to assess myocardial perfusion and ventricular function at the same time. (author)

  15. Evaluation of left ventricular ejection fraction from radial long-axis tomography. A new reconstruction algorithm for ECG-gated technetium-99m Sestamibi SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Tsujimura, Eiichiro; Kusuoka, Hideo; Uehara, Toshiisa [Osaka Univ. (Japan). Faculty of Medicine] [and others

    1997-08-01

    Radial long-axis tomography can provide views similar to contrast left ventriculography (LVG) including the basal and apical areas of the left ventricle, not possible in routine short-axis tomography. We applied this method to ECG-gated Tc-99m Sestamibi (MIBI) myocardial SPECT images to estimate the left ventricular ejection fraction (LVEF). ECG-gated Tc-99m MIBI SPECT was performed with a temporal resolution of 10 frames per R-R interval. LVEF was calculated on the basis of left ventricular volume estimates at end diastole (ED) and end systole (ES) with using an ellipsoid body model. To validate this method, LVEF`s derived from ECG-gated Tc-99m MIBI SPECT were compared with those from LVG in 11 patients with coronary artery disease. There was a close linear correlation between LVEF values calculated from Tc-99m MIBI SPECT and those from LVG (r=0.89, p<0.001), although the gated SPECT underestimated LVEF compared to LVG. The technique showed excellent reproducibility (intra-observer variability, r=0.96, p<0.001; inter-observer variability, r=0.71, p<0.005). The radial long-axis tomography technique gives a good estimate of LVEF, in agreement with estimates based on LVG. ECG-gated Tc-99m MIBI SPECT can, therefore, be applicable to assess myocardial perfusion and ventricular function at the same time. (author)

  16. Vertical force and wrist deviation angle when using a walker to stand up and sit down.

    Science.gov (United States)

    Leung, Cherng-Yee; Yeh, Po-Chan

    2011-08-01

    Research investigating walkers suggests that safety and assistance for the elderly with weak lower limbs were important. However, the relationship between the use of a walker and the upper limbs has received little investigation. Standing up and sitting down are important daily activities. Therefore, the aim of this study was to explore wrist deviation and vertical force among elderly individuals using a walker for assistance to stand up and sit down. In total, 64 elderly volunteers (M age = 80.22, SD = 9.36) were enrolled. Data were obtained from four load cells and a twin-axis wrist goniometer. Wrist deviation and vertical force were examined when participants used a walker with horizontal handles to assist in standing up and sitting down. Significant wrist angle deviation occurred with the use of a walker, with dorsiflexion of the right hand greater than that of the left. Males exerted significantly greater vertical force. In the sitting position, greater ulnar deviation was seen among experienced walker users, whereas during standing, experienced users exhibited greater dorsiflexion. The horizontal handles of most marketed walkers may cause user wrist deviations, suggesting researchers should pursue improvements in walker design.

  17. Thoughts on the so-called 'radius-capitellum axis'

    International Nuclear Information System (INIS)

    Schild, H.; Mueller, H.A.; Wagner, H.; Baetz, W.; Mainz Univ.

    1982-01-01

    We have studied 438 patients radiologically in order to observe the so-called 'radius-capitellum axis'. In about a quarter of people with normal elbows the axis passes lateral to the middle portion of the capitellum, so that even when there is marked deviation, there is no certainty that the humero-radial joint is abnormal. Deviation of the axis can be caused by changes in the shape of the capitellum or of the radius, or by distension of the capsule of the elbow joint, or by various changes in muscular pull. (orig.) [de

  18. Thoughts on the so-called radius-capitellum axis

    Energy Technology Data Exchange (ETDEWEB)

    Schild, H; Mueller, H A; Wagner, H; Baetz, W

    1982-02-01

    We have studied 438 patients radiologically in order to observe the so-called 'radius-capitellum axis'. In about a quarter of people with normal elbows the axis passes lateral to the middle portion of the capitellum, so that even when there is marked deviation, there is no certainty that the humero-radial joint is abnormal. Deviation of the axis can be caused by changes in the shape of the capitellum or of the radius, or by distension of the capsule of the elbow joint, or by various changes in muscular pull.

  19. The phonatory deviation diagram: a novel objective measurement of vocal function.

    Science.gov (United States)

    Madazio, Glaucya; Leão, Sylvia; Behlau, Mara

    2011-01-01

    To identify the discriminative characteristics of the phonatory deviation diagram (PDD) in rough, breathy and tense voices. One hundred and ninety-six samples of normal and dysphonic voices from adults were submitted to perceptual auditory evaluation, focusing on the predominant vocal quality and the degree of deviation. Acoustic analysis was performed with the VoxMetria (CTS Informatica). Significant differences were observed between the dysphonic and normal groups (p < 0.001), and also between the breathy and rough samples (p = 0.044) and the breathy and tense samples (p < 0.001). All normal voices were positioned in the inferior left quadrant, 45% of the rough voices in the inferior right quadrant, 52.6% of the breathy voices in the superior right quadrant and 54.3% of the tense voices in the inferior left quadrant of the PDD. In the inferior left quadrant, 93.8% of voices with no deviation were located and 72.7% of voices with mild deviation; voices with moderate deviation were distributed in the inferior and superior right quadrants, the latter ones containing the most deviant voices and 80% of voices with severe deviation. The PDD was able to discriminate normal from dysphonic voices, and the distribution was related to the type and degree of voice alteration. Copyright © 2011 S. Karger AG, Basel.

  20. Left ventricular long axis function assessed during cine-cardiovascular magnetic resonance is an independent predictor of adverse cardiac events.

    Science.gov (United States)

    Rangarajan, Vibhav; Chacko, Satish Jacob; Romano, Simone; Jue, Jennifer; Jariwala, Nikhil; Chung, Jaehoon; Farzaneh-Far, Afshin

    2016-06-07

    Left ventricular pump function requires a complex interplay involving myocardial fibers orientated in the longitudinal, oblique and circumferential directions. Long axis dysfunction appears to be an early marker for a number of pathological states. We hypothesized that mitral annular plane systolic excursion (MAPSE) measured during cine-cardiovascular magnetic resonance (CMR) reflects changes in long axis function and may be an early marker for adverse cardiovascular outcomes. The aims of this study were therefore: 1) To assess the feasibility and reproducibility of MAPSE measurements during routine cine-CMR; and 2) To assess whether MAPSE, as a surrogate for long axis function, is a predictor of major adverse cardiovascular events (MACE). Four hundred consecutive patients undergoing CMR were prospectively enrolled. MAPSE was measured in the 4-chamber cine view. Patients were prospectively followed for major adverse cardiac events (MACE) - death, non-fatal myocardial infarction, hospitalization for heart failure or unstable angina, and late revascularization. Cox proportional hazards regression modeling was used to identify factors independently associated with MACE. Net reclassification improvement (NRI) was calculated to assess whether addition of MAPSE resulted in improved risk reclassification of MACE. Seventy-two MACE occurred during a median follow-up of 14.5 months. By Kaplan-Meier analysis, patients with lateral MAPSE cine-CMR is an independent predictor of MACE.

  1. Convolutional neural network regression for short-axis left ventricle segmentation in cardiac cine MR sequences.

    Science.gov (United States)

    Tan, Li Kuo; Liew, Yih Miin; Lim, Einly; McLaughlin, Robert A

    2017-07-01

    Automated left ventricular (LV) segmentation is crucial for efficient quantification of cardiac function and morphology to aid subsequent management of cardiac pathologies. In this paper, we parameterize the complete (all short axis slices and phases) LV segmentation task in terms of the radial distances between the LV centerpoint and the endo- and epicardial contours in polar space. We then utilize convolutional neural network regression to infer these parameters. Utilizing parameter regression, as opposed to conventional pixel classification, allows the network to inherently reflect domain-specific physical constraints. We have benchmarked our approach primarily against the publicly-available left ventricle segmentation challenge (LVSC) dataset, which consists of 100 training and 100 validation cardiac MRI cases representing a heterogeneous mix of cardiac pathologies and imaging parameters across multiple centers. Our approach attained a .77 Jaccard index, which is the highest published overall result in comparison to other automated algorithms. To test general applicability, we also evaluated against the Kaggle Second Annual Data Science Bowl, where the evaluation metric was the indirect clinical measures of LV volume rather than direct myocardial contours. Our approach attained a Continuous Ranked Probability Score (CRPS) of .0124, which would have ranked tenth in the original challenge. With this we demonstrate the effectiveness of convolutional neural network regression paired with domain-specific features in clinical segmentation. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Current status of ultrafast CT to evaluate the left ventricle

    International Nuclear Information System (INIS)

    MacMillan, R.M.; Rees, M.R.; Maranhao, V.

    1987-01-01

    Contrast-enhanced ultrafast CT with the cine mode can enable reliable assessment of left ventricular mass and function. Two oblique planar views, the long axis and short axis, are required. Right and left ventricular end-diastolic volumes, end-systolic volumes, stroke volume and ejection fraction, left ventricular segmental wall motion, and left ventricular mass can be measured. This exhibit emphasizes the methods and pitfalls in acquiring this information. Results from the authors' studies thus far to validate these measurements against reference standards are reviewed

  3. Tooth axis and skeletal structures in mandibular molar vertical sections in jaw deformity with facial asymmetry using MPR images

    International Nuclear Information System (INIS)

    Nojima, Kunihiko; Yokose, Taishi; Ishii, Takenobu; Kobayashi, Makoto; Nishii, Yasushi

    2007-01-01

    The objective of the present study was to investigate frontal morphological asymmetry in the mandibular molar region in terms of tooth axis and skeletal structures using vertical MPR sections in jaw deformity accompanied by facial asymmetry. Subjects consisted of 15 patients with jaw deformity accompanied by facial asymmetry aged 17.4 years to 37.8 years. There were four men and eleven women. Based on X-ray computed tomography (CT) scans, Digital Imaging and Communications in Medicine (DICOM) viewer software was used to prepare multiplanar reconstruction (MPR) sections. The mandible was then positioned on a reference plane based on the menton and left and right gonions, and a vertical MPR section passing through the mesial root of the first mandibular molar was prepared. The following measurements were made on both the shifted and non-shifted sides: maximum buccolingual width of the mandibular body; height of the mandibular body; inclination angle of the mandibular body; degree of buccal protrusion of the mandibular body; and inclination angle of the buccolingual tooth axis of the first molar. Furthermore, degree of median deviation in the menton was measured using frontal cephalograms. Differences in morphological parameters between the shifted and non-shifted sides were assessed. Furthermore, the relationship between median deviation and asymmetry were statistically analyzed. There was no significant asymmetry in the maximum buccolingual width of the mandibular body, the height of the mandibular body or the degree of buccal protrusion of the mandibular body. However, when compared to the shifted side, the inclination angle of the buccolingual tooth axis of the first molar for the non-shifted side was significantly greater. There was a relatively strong correlation between median deviation and inclination angle of the mandibular body. The above findings clarified that, in orthognathic surgery for jaw deformity accompanied by facial asymmetry, actively improving

  4. Pure Left Neglect for Arabic Numerals

    Science.gov (United States)

    Priftis, Konstantinos; Albanese, Silvia; Meneghello, Francesca; Pitteri, Marco

    2013-01-01

    Arabic numerals are diffused and language-free representations of number magnitude. To be effectively processed, the digits composing Arabic numerals must be spatially arranged along a left-to-right axis. We studied one patient (AK) to show that left neglect, after right hemisphere damage, can selectively impair the computation of the spatial…

  5. Left Right Patterning, Evolution and Cardiac Development

    Science.gov (United States)

    Dykes, Iain M.

    2018-01-01

    Many aspects of heart development are determined by the left right axis and as a result several congenital diseases have their origins in aberrant left-right patterning. Establishment of this axis occurs early in embryogenesis before formation of the linear heart tube yet impacts upon much later morphogenetic events. In this review I discuss the differing mechanisms by which left-right polarity is achieved in the mouse and chick embryos and comment on the evolution of this system. I then discus three major classes of cardiovascular defect associated with aberrant left-right patterning seen in mouse mutants and human disease. I describe phenotypes associated with the determination of atrial identity and venous connections, looping morphogenesis of the heart tube and finally the asymmetric remodelling of the embryonic branchial arch arterial system to form the leftward looped arch of aorta and associated great arteries. Where appropriate, I consider left right patterning defects from an evolutionary perspective, demonstrating how developmental processes have been modified in species over time and illustrating how comparative embryology can aide in our understanding of congenital heart disease. PMID:29755990

  6. On the generation of short-axis and radial long-axis slices in thallium-201 myocardial perfusion single-photon emission tomography

    International Nuclear Information System (INIS)

    Hastenberg, R.P.J.M. van; Eindhoven Univ. of Technology; Kemernik, G.J.; Hasman, A.

    1996-01-01

    We tried to develop fully automatic reorientation algorithms in thallium-201 myocardial perfusion single-photon emission tomography, and tested a method to evaluate the quality of reorientation. The left ventricle was automatically segmented using count density information, contours generated with Laplacian operators in both transaxial and sagittal slices, and morphological and positional characteristics of the contours. Reorientation was automatically performed based on knowledge of the long axis of a second degree surface fitted to the myocardial wall. We tried to achieve improvement in reorientation without relying on any functional description of left ventricular shape. Quality of reorientation was evaluated and improved using interactive tools in combination with radial long-axis slices. Two groups of 50 patients, after stress and rest, were analysed using the traditional manual and the fully automatic procedures. Automatic segmentation was successful in 98 out of 100 cases, and automatic reorientation was of reasonable quality. Reorientation obtained with the radial long-axis slices tool was better than after traditional manual or automatic reorientation. Automatic reorientation based on second degree surface fitting was in our hands less successful than reported in the literature. The tool using radial long-axis slices provides a better standard for testing reorientation algorithms than the traditional manual method. (orig.)

  7. The Role of Cerl2 in the Establishment of Left-Right Asymmetries during Axis Formation and Heart Development

    Directory of Open Access Journals (Sweden)

    José A. Belo

    2017-12-01

    Full Text Available The formation of the asymmetric left-right (LR body axis is one of the fundamental aspects of vertebrate embryonic development, and one still raising passionate discussions among scientists. Although the conserved role of nodal is unquestionable in this process, several of the details around this signaling cascade are still unanswered. To further understand this mechanism, we have been studying Cerberus-like 2 (Cerl2, an inhibitor of Nodal, and its role in the generation of asymmetries in the early vertebrate embryo. The absence of Cerl2 results in a wide spectrum of malformations commonly known as heterotaxia, which comprises defects in either global organ position (e.g., situs inversus totalis, reversed orientation of at least one organ (e.g., situs ambiguus, and mirror images of usually asymmetric paired organs (e.g., left or right isomerisms of the lungs. Moreover, these laterality defects are frequently associated with congenital heart diseases (e.g., transposition of the great arteries, or atrioventricular septal defects. Here, reviewing the knowledge on the establishment of LR asymmetry in mouse embryos, the emerging conclusion is that as necessary as is the activation of the Nodal signaling cascade, the tight control that Cerl2-mediates on Nodal signaling is equally important, and that generates a further regionalized LR genetic program in the proper time and space.

  8. Vertebrate Left-Right Asymmetry: What Can Nodal Cascade Gene Expression Patterns Tell Us?

    Science.gov (United States)

    Schweickert, Axel; Ott, Tim; Kurz, Sabrina; Tingler, Melanie; Maerker, Markus; Fuhl, Franziska; Blum, Martin

    2017-12-29

    Laterality of inner organs is a wide-spread characteristic of vertebrates and beyond. It is ultimately controlled by the left-asymmetric activation of the Nodal signaling cascade in the lateral plate mesoderm of the neurula stage embryo, which results from a cilia-driven leftward flow of extracellular fluids at the left-right organizer. This scenario is widely accepted for laterality determination in wildtype specimens. Deviations from this norm come in different flavors. At the level of organ morphogenesis, laterality may be inverted (situs inversus) or non-concordant with respect to the main body axis (situs ambiguus or heterotaxia). At the level of Nodal cascade gene activation, expression may be inverted, bilaterally induced, or absent. In a given genetic situation, patterns may be randomized or predominantly lacking laterality (absence or bilateral activation). We propose that the distributions of patterns observed may be indicative of the underlying molecular defects, with randomizations being primarily caused by defects in the flow-generating ciliary set-up, and symmetrical patterns being the result of impaired flow sensing, on the left, the right, or both sides. This prediction, the reasoning of which is detailed in this review, pinpoints functions of genes whose role in laterality determination have remained obscure.

  9. Detection and evaluation of left atrial myxoma by gated radionuclide imaging

    International Nuclear Information System (INIS)

    Sugihara, Hiroki; Adachi, Haruhiko; Nakagawa, Hiroaki

    1985-01-01

    Radionuclide imaging plays an important role in diagnosising left atrial myxoma (LAM). We discussed diagnostic value of Fourier analysis with phase image and evaluated left ventricular filling function using indices such as 1/3 Filling Fraction, Rapid Filling Fraction and Peak Filling Rate derived from left ventricular volume curve. Equillibrium radionuclide angiocardiography was performed in 6 LAM patients. Phase delay in the basal portion of the left ventricle was shown in 5 of 6 LAM patients, and standard deviation of left ventricular phase was larger than these of controls. Left ventricular filling disturbance was suggested in 5 of 6 LAM patients. After surgical remove of myxoma phase delay was disappeared and standard deviation was normalized. And left ventricular filling was improved. We concluded that the phase image of Fourier analysis revealed a left atrial mass prolapsing in the left ventricule during the diastole, and that diastolic indices were useful for left ventricular filling disturbance due to LAM. (author)

  10. Normal left ventricular wall motion measured with two-dimensional myocardial tagging

    DEFF Research Database (Denmark)

    Qi, P; Thomsen, C; Ståhlberg, F

    1993-01-01

    contraction towards the center of the left ventricle, a motion of the base of the heart towards the apex, and a rotation of the left ventricle around its long axis. The direction of left ventricular rotation changed from early systole to late systole. The base and middle levels of the left ventricle rotated...

  11. Validation of Left Atrial Volume Estimation by Left Atrial Diameter from the Parasternal Long-Axis View.

    Science.gov (United States)

    Canciello, Grazia; de Simone, Giovanni; Izzo, Raffaele; Giamundo, Alessandra; Pacelli, Filomena; Mancusi, Costantino; Galderisi, Maurizio; Trimarco, Bruno; Losi, Maria-Angela

    2017-03-01

    Measurement of left atrial (LA) volume (LAV) is recommended for quantification of LA size. Only LA anteroposterior diameter (LAd) is available in a number of large cohorts, trials, or registries. The aim of this study was to evaluate whether LAV may be reasonably estimated from LAd. One hundred forty consecutive patients referred to our outpatient clinics were prospectively enrolled to measure LAd from the long-axis view on two-dimensional echocardiography. LA orthogonal dimensions were also taken from apical four- and two-chamber views. LAV was measured using the Simpson, area-length, and ellipsoid (LAV e ) methods. The first 70 patients were the learning series and the last 70 the testing series (TeS). In the learning series, best-fitting regression analysis of LAV-LAd was run using all LAV methods, and the highest values of F were chosen among the regression equations. In the TeS, the best-fitting regressions were used to estimate LAV from LAd. In the learning series, the best-fitting regression was linear for the Spearman method (r 2  = 0.62, F = 111.85, P = .0001) and area-length method (r 2  = 0.62, F = 112.24, P = .0001) and powered for the LAV e method (r 2  = 0.81, F = 288.41, P = .0001). In the TeS, the r 2 value for LAV prediction was substantially better using the LAV e method (r 2  = 0.89) than the Simpson (r 2  = 0.72) or area-length (r 2  = 0.70) method, as was the intraclass correlation (ρ = 0.96 vs ρ = 0.89 and ρ = 0.89, respectively). In the TeS, the sensitivity and specificity of LA dilatation by the estimated LAV e method were 87% and 90%, respectively. LAV can be estimated from LAd using a nonlinear equation with an elliptical model. The proposed method may be used in retrospective analysis of existing data sets in which determination of LAV was not programmed. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  12. Radiofrequency Catheter Ablation of Coexistent Idiopathic Left Ventricular Tachycardia and Atrioventricular Nodal Reentrant Tachycardia

    Directory of Open Access Journals (Sweden)

    Ken-Pen Weng

    2005-10-01

    Full Text Available A healthy 15-year-old male patient presented with a 6-month history of recurrent attacks of palpitations. On multiple emergency room visits, a sustained wide QRS complex tachycardia with a right bundle branch block and northwest axis deviation was documented. The tachycardia was not terminated by intravenous adenosine, but was suppressed with intravenous verapamil. There was no evidence of structural heart disease, myocarditis, long QT syndrome, or electrolyte imbalance after a series of standard examinations. Idiopathic left ventricular tachycardia (ILVT was suspected. Electrophysiologic studies revealed 2 inducible tachycardias, which were shown to represent atrioventricular nodal reentrant tachycardia (AVNRT and ILVT. Transformation from AVNRT to ILVT occurred spontaneously following atrial pacing. Successful ablation of ILVT and the slow atrioventricular nodal pathway resulted in cure of the double tachycardia.

  13. Optic axis-driven new horizons for hyperbolic metamaterials

    Directory of Open Access Journals (Sweden)

    Boardman Allan D.

    2015-01-01

    Full Text Available The broad assertion here is that the current hyperbolic metamaterial world is only partially served by investigations that incorporate only some limited version of anisotropy. Even modest deviations of the optic axis from the main propagation axis lead to new phase shifts, which not only compete with those created by absorption but end up dominating them. Some progress has been attempted in the literature by introducing the terms “asymmetric hyperbolic media”, but it appears that this kind of asymmetry only involves an optic axis at an angle to the interface of a uniaxial crystal. From a device point of view, many new prospects should appear and the outcomes of the investigations presented here yield a new general theory. It is emphasised that the orientation of the optic axis is a significant determinant in the resulting optical properties. Whereas for conventional anisotropic waveguides homogeneous propagating waves occur over a limited range of angular dispositions of the optic axis it is shown that for a hyperbolic guide a critical angular setting exists, above which the guided waves are always homogeneous. This has significant implications for metawaveguide designs. The resulting structures are more tolerant to optic axis misalignment.

  14. Left ventricular systolic function in sickle cell anaemia: an ...

    African Journals Online (AJOL)

    42) and 24.17 ± 4.39 ... Aortic root diameter (Ao), left atrial dimension (LAD), left ventricu- ... Key: *Statistically significant, a= Chi-square, SCA= sickle cell anaemia, SD= standard deviation. ..... of fluctuations in response to changes in sympathetic.

  15. An Asymptomatic Case of Wolff-Parkinson-White Syndrome with Right-sided Free-wall Accessory Pathway and Left Ventricular Dysfunction

    Directory of Open Access Journals (Sweden)

    Takanao Mine, MD

    2011-01-01

    Full Text Available A 16-year-old girl with a known history of asymptomatic Wolff-Parkinson-White syndrome exhibited signs of left ventricular (LV septal akinesia and LV dysfunction during routine follow-up. A 12-lead surface ECG showed pre-excitation, a predominantly negative delta wave in V1 and left axis deviation, which was consistent with the presence of a right free-wall accessory pathway. Radiofrequency ablation of the anterolateral right atrium around the local shortest atrium-to-ventricle interval created the accessory pathway block. An echocardiogram taken one month after the procedure revealed that LV septal wall motion had normalized and that LV ejection fraction had improved from 50% before the ablation to 64% after the ablation. Most previous reports of asymptomatic patients of WPW with LV septal dyskinesia and dysfunction have described right septal or posteroseptal accessory pathways. This patient reported here represents a rare case with right free-wall accessory pathway and LV dysfunction without tachycardia.

  16. Perception of midline deviations in smile esthetics by laypersons.

    Science.gov (United States)

    Ferreira, Jamille Barros; Silva, Licínio Esmeraldo da; Caetano, Márcia Tereza de Oliveira; Motta, Andrea Fonseca Jardim da; Cury-Saramago, Adriana de Alcantara; Mucha, José Nelson

    2016-01-01

    To evaluate the esthetic perception of upper dental midline deviation by laypersons and if adjacent structures influence their judgment. An album with 12 randomly distributed frontal view photographs of the smile of a woman with the midline digitally deviated was evaluated by 95 laypersons. The frontal view smiling photograph was modified to create from 1 mm to 5 mm deviations in the upper midline to the left side. The photographs were cropped in two different manners and divided into two groups of six photographs each: group LCN included the lips, chin, and two-thirds of the nose, and group L included the lips only. The laypersons performed the rate of each smile using a visual analog scale (VAS). Wilcoxon test, Student's t-test and Mann-Whitney test were applied, adopting a 5% level of significance. Laypersons were able to perceive midline deviations starting at 1 mm. Statistically significant results (p< 0.05) were found for all multiple comparisons of the values in photographs of group LCN and for almost all comparisons in photographs of group L. Comparisons between the photographs of groups LCN and L showed statistically significant values (p< 0.05) when the deviation was 1 mm. Laypersons were able to perceive the upper dental midline deviations of 1 mm, and above when the adjacent structures of the smiles were included. Deviations of 2 mm and above when the lips only were included. The visualization of structures adjacent to the smile demonstrated influence on the perception of midline deviation.

  17. An augmented reality C-arm for intraoperative assessment of the mechanical axis: a preclinical study.

    Science.gov (United States)

    Fallavollita, Pascal; Brand, Alexander; Wang, Lejing; Euler, Ekkehard; Thaller, Peter; Navab, Nassir; Weidert, Simon

    2016-11-01

    Determination of lower limb alignment is a prerequisite for successful orthopedic surgical treatment. Traditional methods include the electrocautery cord, alignment rod, or axis board which rely solely on C-arm fluoroscopy navigation and are radiation intensive. To assess a new augmented reality technology in determining lower limb alignment. A camera-augmented mobile C-arm (CamC) technology was used to create a panorama image consisting of hip, knee, and ankle X-rays. Twenty-five human cadaver legs were used for validation with random varus or valgus deformations. Five clinicians performed experiments that consisted in achieving acceptable mechanical axis deviation. The applicability of the CamC technology was assessed with direct comparison to ground-truth CT. A t test, Pearson's correlation, and ANOVA were used to determine statistical significance. The value of Pearson's correlation coefficient R was 0.979 which demonstrates a strong positive correlation between the CamC and ground-truth CT data. The analysis of variance produced a p value equal to 0.911 signifying that clinician expertise differences were not significant with regard to the type of system used to assess mechanical axis deviation. All described measurements demonstrated valid measurement of lower limb alignment. With minimal effort, clinicians required only 3 X-ray image acquisitions using the augmented reality technology to achieve reliable mechanical axis deviation.

  18. [A new kinematics method of determing elbow rotation axis and evaluation of its feasibility].

    Science.gov (United States)

    Han, W; Song, J; Wang, G Z; Ding, H; Li, G S; Gong, M Q; Jiang, X Y; Wang, M Y

    2016-04-18

    To study a new positioning method of elbow external fixation rotation axis, and to evaluate its feasibility. Four normal adult volunteers and six Sawbone elbow models were brought into this experiment. The kinematic data of five elbow flexion were collected respectively by optical positioning system. The rotation axes of the elbow joints were fitted by the least square method. The kinematic data and fitting results were visually displayed. According to the fitting results, the average moving planes and rotation axes were calculated. Thus, the rotation axes of new kinematic methods were obtained. By using standard clinical methods, the entrance and exit points of rotation axes of six Sawbone elbow models were located under X-ray. And The kirschner wires were placed as the representatives of rotation axes using traditional positioning methods. Then, the entrance point deviation, the exit point deviation and the angle deviation of two kinds of located rotation axes were compared. As to the four volunteers, the indicators represented circular degree and coplanarity of elbow flexion movement trajectory of each volunteer were both about 1 mm. All the distance deviations of the moving axes to the average moving rotation axes of the five volunteers were less than 3 mm. All the angle deviations of the moving axes to the average moving rotation axes of the five volunteers were less than 5°. As to the six Sawbone models, the average entrance point deviations, the average exit point deviations and the average angle deviations of two different rotation axes determined by two kinds of located methods were respectively 1.697 2 mm, 1.838 3 mm and 1.321 7°. All the deviations were very small. They were all in an acceptable range of clinical practice. The values that represent circular degree and coplanarity of volunteer's elbow single curvature movement trajectory are very small. The result shows that the elbow single curvature movement can be regarded as the approximate fixed

  19. Lazer-Leach Type Conditions on Periodic Solutions of Liénard Equation with a Deviating Argument at Resonance

    OpenAIRE

    Wang, Zaihong

    2013-01-01

    We study the existence of periodic solutions of Liénard equation with a deviating argument $x\\mathrm{\\prime \\prime }+f\\left(x\\right)x\\mathrm{\\text{'}}+{n}^{\\mathrm{2}}x+g\\left(x\\left(t-\\tau \\right)\\right)=p\\left(t\\right),$ where $f,g,p:\\mathrm{R}\\to \\mathrm{R}$ are continuous and $p$ is $\\mathrm{2}\\pi $ -periodic, $\\mathrm{0}\\le \\tau

  20. Three-Axis Ground Reaction Force Distribution during Straight Walking.

    Science.gov (United States)

    Hori, Masataka; Nakai, Akihito; Shimoyama, Isao

    2017-10-24

    We measured the three-axis ground reaction force (GRF) distribution during straight walking. Small three-axis force sensors composed of rubber and sensor chips were fabricated and calibrated. After sensor calibration, 16 force sensors were attached to the left shoe. The three-axis force distribution during straight walking was measured, and the local features of the three-axis force under the sole of the shoe were analyzed. The heel area played a role in receiving the braking force, the base area of the fourth and fifth toes applied little vertical or shear force, the base area of the second and third toes generated a portion of the propulsive force and received a large vertical force, and the base area of the big toe helped move the body's center of mass to the other foot. The results demonstrate that measuring the three-axis GRF distribution is useful for a detailed analysis of bipedal locomotion.

  1. Large deviations

    CERN Document Server

    Varadhan, S R S

    2016-01-01

    The theory of large deviations deals with rates at which probabilities of certain events decay as a natural parameter in the problem varies. This book, which is based on a graduate course on large deviations at the Courant Institute, focuses on three concrete sets of examples: (i) diffusions with small noise and the exit problem, (ii) large time behavior of Markov processes and their connection to the Feynman-Kac formula and the related large deviation behavior of the number of distinct sites visited by a random walk, and (iii) interacting particle systems, their scaling limits, and large deviations from their expected limits. For the most part the examples are worked out in detail, and in the process the subject of large deviations is developed. The book will give the reader a flavor of how large deviation theory can help in problems that are not posed directly in terms of large deviations. The reader is assumed to have some familiarity with probability, Markov processes, and interacting particle systems.

  2. Usefulness of Non-coplanar Helical Tomotherapy Using Variable Axis Baseplate

    International Nuclear Information System (INIS)

    Ha, Jin Sook; Chung, Yoon Sun; Lee, Ik Jae; Shin, Dong Bong; Kim, Jong Dae; Kim, Sei Joon; Jeon, Mi Jin; Chok, Yoon Jin; Kim, Ki Kwang; Lee, Seul Bee

    2011-01-01

    who did not use, but the mean of Y-axis movement was lower by at least 64%, and the mean of Z-axis was lower by at least 67%, and the mean of Z-axis was lower by at least 67%, and the vector was lower by at least 59% with the use of a mouthpiece. Among these 8 patients, one patient whose tumor was located on left frontal lobe and left basal ganglia received reduced radiation dose of 38% in right eye, 23% in left eye, 30% in optic chiasm, 27% in brain stem, and 8% in normal brain with non-coplanar method. Tomotherapy only allows coplanar delivery of IMRT treatment. To complement this shortcoming, Tomotherapy can be used with non-coplanar method by artificially tilting the patient's head and using an oral immobilization instrument to minimize the movement of patient, when intracranial tumor locates near critical organs or has to be treated with high dose radiation.

  3. The roles of the Q (q) wave in lead I and QRS frontal axis for diagnosing loss of left ventricular capture during cardiac resynchronization therapy.

    Science.gov (United States)

    Cao, Yuan-Yuan; Su, Yan-Gang; Bai, Jin; Wang, Wei; Wang, Jing-Feng; Qin, Sheng-Mei; Ge, Jun-Bo

    2015-01-01

    Loss of left ventricular (LV) capture may lead to deterioration of heart failure in patients with cardiac resynchronization therapy (CRT). Recognition of loss of LV capture in time is important in clinical practice. A total of 422 electrocardiograms were acquired and analyzed from 53 CRT patients at 8 different pacing settings (LV only, right ventricle [RV] only, biventricular [BV] pacing with LV preactivation of 60, 40, 20, and 0 milliseconds and RV preactivation of 20 and 40 milliseconds). A modified Ammann algorithm by adding a third step-presence of Q (q, or QS) wave-to the original 2-step Ammann algorithm and a QRS axis shift method were devised to identify the loss of LV capture. The accuracy of modified Ammann algorithm was significantly higher than that of Ammann algorithm (78.9% vs. 69.1%, P capture. The LV preactivation, or simultaneous BV activation and LV lead positioned in nonposterior or noninferior wall can increase the diagnostic power of the modified Ammann algorithm and QRS axis shift method. © 2014 Wiley Periodicals, Inc.

  4. Optical performance of inclined south-north single-axis tracked solar panels

    International Nuclear Information System (INIS)

    Li, Zhimin; Liu, Xinyue; Tang, Runsheng

    2010-01-01

    To investigate optical performance of the inclined south-north single-axis (ISN-axis, in short) tracked solar panels, a mathematical procedure to estimate the annual collectible radiation on fixed and tracked panels was suggested based on solar geometry and monthly horizontal radiation. For solar panels tracking about ISN-axis, the yearly optimal tilt-angle of ISN-axis for maximizing annual solar gain was about 3 o deviating from the site latitude in most of China except in areas with poor solar resources, and the maximum annual collectible radiation on ISN-axis tracked panels was about 97-98% of that on dual-axis tracked panels; whereas for ISN-axis tracked panels with the tilt-angle of ISN-axis being adjusted four times in a year at three fixed tilt-angles, the annual collectible radiation was almost close to that on dual-axis tracked panels, the optimum date of tilt-angle adjustment of ISN-axis was 23 days from the equinoxes, and the optimum tilt-angle adjustment value for each adjustment was about 22 o . Compared to fixed south-facing solar panels inclined at an optimal tilt-angle, the increase in the annual solar gain due to using ISN-axis sun tracking was above 30% in the areas with abundant solar resources and less than 20% in the areas with poor solar resources.

  5. Pre-maxillary complex morphology in bilateral cleft and hypothesis on laterality of deviated pre-maxilla

    Directory of Open Access Journals (Sweden)

    Jyotsna Murthy

    2016-01-01

    Full Text Available Introduction: Pre-maxillary complex (pre-maxilla [PMX] + vomer morphology in bilateral complete cleft of primary and secondary palate (BCLCP is very complex and less reviewed in literature. Materials and Methods: In this retrospective cross-sectional study, 200 consecutive BCLCP patients were selected. Their pre-operative clinical photographs and dental casts were evaluated by a single investigator at two different points of time, to study the morphology of PMX and vomer with special emphasis on deviation of vomer and rotation of PMX. Results: It is found that in above 70% of patients, PMX and vomer both displaced or deviated towards left side in horizontal plane and PMX rotated anticlockwise at PMX vomerine suture (PVS. In 10% of cases, both PMX and vomer are displaced towards the right side, PMX rotated clockwise at PVS. In 11% of cases, vomer is displaced towards the left side, but PMX rotated clockwise at PVS. In 5% of cases, vomer is displaced towards the right side, but PMX rotated anticlockwise at PVS. Both PMX and vomer are in midline in 4% of cases. Conclusion: Specific morphological deviation of vomer and PMX has been studied. We put forward the probable hypothesis to explain the deviation and rotation of PMX.

  6. Pattern of ECG abnormalities in Nigerian hypertensive patients seen ...

    African Journals Online (AJOL)

    1%, left axis deviation(LAD) in 30.3%, sinus tachycardia 25.0%,left atrial enlargement(LAE) in 21.2%, atrial fibrillation(AF) in 3.8%, right bundle branch block (RBBB) in 1.5% and left anterior hemi block (LAH) in 0.8%. There were no cases of ...

  7. On the Horizontal Deviation of a Spinning Projectile Penetrating into Granular Systems

    Directory of Open Access Journals (Sweden)

    Waseem Ghazi Alshanti

    2017-01-01

    Full Text Available The absence of a general theory that describes the dynamical behavior of the particulate materials makes the numerical simulations the most current powerful tool that can grasp many mechanical problems relevant to the granular materials. In this paper, based on a two-dimensional soft particle discrete element method (DEM, a numerical approach is developed to investigate the consequence of the orthogonal impact into various granular beds of projectile rotating in both clockwise (CW and counterclockwise (CCW directions. Our results reveal that, depending on the rotation direction, there is a significant deviation of the x-coordinate of the final stopping point of a spinning projectile from that of its original impact point. For CW rotations, a deviation to the right occurs while a left deviation has been recorded for CCW rotation case.

  8. Laterality of a second player position affects lateral deviation of basketball shooting.

    Science.gov (United States)

    Viggiano, Andrea; Chieffi, Sergio; Tafuri, Domenico; Messina, Giovanni; Monda, Marcellino; De Luca, Bruno

    2014-01-01

    Asymmetrically placed visual distractors are known to cause a lateral bias in the execution of a movement directed toward a target. The aim of the present experiment was to verify if the trajectory of the ball and the trajectory of the jump for a basket-shot can be affected by the sole position of a second player, who stays in front of the shooting player in one of three possible positions (centre, left or right) but too far to physically interfere with the shot. Young basketball players were asked to perform 60 shots at 6.25 m from a regular basket, with or without a second player staying in front of them in, alternately, a centre, left or right position. A computerised system measured the angular deviation of the jump direction from the vertical direction and the lateral deviation of the ball trajectory from the midline. The results showed that both the jump direction and the entry position of the ball deviated toward the opposite side from the second player's side; however, these effects were too small to significantly affect the mean goal percentage. This result confirms that some placements of the players can have an effect as visual distractors. Further studies are necessary to find what game conditions can make such distractors harmful for the athletic performance.

  9. Long-axis fractional shortening and mitral annulus motion in dogs

    Directory of Open Access Journals (Sweden)

    Marlos Gonçalves Sousa

    2016-10-01

    Full Text Available Ventricular systolic dynamics involves the contraction of transverse and longitudinal myocardial fibers. Unfortunately, only the activity of the transverse myocardial fibers is foreseen by the standard systolic echocardiographic parameters. Although strain and strain rate have been used to assess the radial, circumferential and longitudinal planes of cardiac contraction, such analysis requires advanced equipment which is not always available in veterinary medicine. On the contrary, some unusual parameters may be recorded via standard methodology, allowing for the specific evaluation of left ventricular longitudinal contractility. In this study, the longitudinal contractile activity was evaluated using the long-axis fractional shortening and the mitral annulus motion, which were compared with several standard echocardiographic parameters in 14 beagles, including seven with asymptomatic mitral valve disease. The long-axis fractional shortening was positively correlated with both the mitral annulus motion and the end-diastolic left-ventricular diameter. Also, a significant correlation was found to exist between the mitral annulus motion and the left-ventricular end-diastolic diameter, which is likely supportive of its preload dependency. Even though no difference was documented in either mitral annulus motion or long-axis fractional shortening between healthy dogs and dogs with mitral valve disease, the latter only included animals with minimal cardiac remodeling, with no overt compromise of systolic function. Since it is possible to obtain these two parameters with any echocardiographic equipment, their inclusion in the routine exam would probably add information regarding the activity of the longitudinal myocardial fibers, whose functional deterioration supposedly occurs prior to the impairment of transverse fibers.

  10. Evaluation of left ventricular volume by MRI using modified Simpson's rule method

    International Nuclear Information System (INIS)

    Okamura, Masahiro; Kondo, Takeshi; Anno, Naoko

    1990-01-01

    The conventional contrast left ventriculogrpahy (LVG) has been the gold standard for estimating left ventricular volume (LVV), but it is an invasive technique, and volume overload must be caused by contrast medium. the true left ventricular (LV) long axis may not be obtained by LVG in routine right anterior oblique (RAO) projection. MRI, on the other hand, is noninvasive, does not require contrast medium, and permits to obtain the true LV long axis sections. Thus, MRI seems the ideal technique for estimating LVV. To estimate LVV, we have developed the on-line programs for calculating LVV by single-plane (SMS) or biplane modified Simpson's rule method (BMS), and have applied these programs to the water in the bottle with the elliptic short axis plane, normal volunteer and patients with various heart diseases. In the water phantom, the water volume calculated by the BMS was more accurate than the SMS. In nine normal volunteers, multiple LV short axis sections in each end-systole and end-diastole were obtained by ECG-gated spin echo MRI, LVV as standard was calculated by true Simpson's rule method (TS) on these images. Then both vertical and horizontal LV long axis sections were also obtained by ECG-gated field echo (FE) rephasing cine MRI, LVV was calculated by the BMS or SMS on these images. The BMS or SMS significantly correlated (r=0.974, r=0.927, 0.947) with TS for estimating LVV, respectively. In 20 patients with various heart diseases, both vertical and horizontal LV long axis sections were obtained by FE cine MRI. LVV (r=0.907 and r=0.901) and EF (r=0.822 and r=0.938) calculated by the SMS on the vertical or horizontal LV long axis sections significantly correlated with the conventional RAO-LVG, respectively. In conclusion, the MRI using our on-line programs would be clinically useful for estimating LVV and EF. (author)

  11. A morphological study of the masseter muscle using magnetic resonance imaging in patients with jaw deformities. Cases demonstrating mandibular deviation

    International Nuclear Information System (INIS)

    Higashi, Katsuhiko; Goto, Tazuko K.; Kanda, Shigenobu; Shiratsuchi, Yuji; Nakashima, Akihiko; Horinouchi, Yasufumi

    2006-01-01

    Numerous studies on the cross-sectional area of masticatory muscles, which are correlated to the facial shape, have been reported for normal subjects in previous articles. However to date, there have been no such studies on masseter muscles at jaw-closing and jaw-opening in patients with jaw deformities involving mandibular deviation. The MRI data sets of the masseter muscles at jaw-closing and jaw-opening in 14 female patients with mandibular deviation, who demonstrated a more than 3-mm deviation in the median line in the lower first incisors in comparison to the upper ones, were utilized. The cross-sectional areas from the origin to the insertion at jaw-closing and jaw-opening which were reconstructed perpendicular to the three-dimensional long axis of each masseter muscle, each maximum cross-sectional area (MCSA) and the ratio of the change in MCSA after jaw-opening were analyzed. As a result, a significant difference was observed between the MCSA at jaw-closing and jaw-opening on the same side. However, no difference in MCSA was seen between the deviated and non-deviated side of the mandible. The line chart patterns of the masseter muscles from the origin to the insertion could be classified into four types. Our results suggest that it is important to analyze cross-sectional areas of the masseter muscles in each subject while considering the three-dimensional axis of each muscle. (author)

  12. A correlational study of scoliosis and trunk balance in adult patients with mandibular deviation.

    Directory of Open Access Journals (Sweden)

    Shuncheng Zhou

    Full Text Available Previous studies have confirmed that patients with mandibular deviation often have abnormal morphology of their cervical vertebrae. However, the relationship between mandibular deviation, scoliosis, and trunk balance has not been studied. Currently, mandibular deviation is usually treated as a single pathology, which leads to poor clinical efficiency. We investigated the relationship of spine coronal morphology and trunk balance in adult patients with mandibular deviation, and compared the finding to those in healthy volunteers. 35 adult patients with skeletal mandibular deviation and 10 healthy volunteers underwent anterior X-ray films of the head and posteroanterior X-ray films of the spine. Landmarks and lines were drawn and measured on these films. The axis distance method was used to measure the degree of scoliosis and the balance angle method was used to measure trunk balance. The relationship of mandibular deviation, spine coronal morphology and trunk balance was evaluated with the Pearson correlation method. The spine coronal morphology of patients with mandibular deviation demonstrated an "S" type curve, while a straight line parallel with the gravity line was found in the control group (significant difference, p1°, while the control group had a normal trunk balance (imbalance angle <1°. There was a significant difference between the two groups (p<0.01. The degree of scoliosis and shoulder imbalance correlated with the degree of mandibular deviation, and presented a linear trend. The direction of mandibular deviation was the same as that of the lateral bending of thoracolumbar vertebrae, which was opposite to the direction of lateral bending of cervical vertebrae. Our study shows the degree of mandibular deviation has a high correlation with the degree of scoliosis and trunk imbalance, all the three deformities should be clinically evaluated in the management of mandibular deviation.

  13. Automatic extraction of left ventricle in SPECT myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Liu Li; Zhao Shujun; Yao Zhiming; Wang Daoyu

    1999-01-01

    An automatic method of extracting left ventricle from SPECT myocardial perfusion data was introduced. This method was based on the least square analysis of the positions of all short-axis slices pixels from the half sphere-cylinder myocardial model, and used a iterative reconstruction technique to automatically cut off the non-left ventricular tissue from the perfusion images. Thereby, this technique provided the bases for further quantitative analysis

  14. Left ventricular systolic and diastolic function in hyperthyroidism

    International Nuclear Information System (INIS)

    Friedman, M.J.; Okada, R.D.; Ewy, G.A.; Hellman, D.J.

    1982-01-01

    In order to assess the effect of hyperthyroidism on systolic and diastolic function of the left ventricle, M-mode echocardiograms and systolic time intervals were obtained in 13 patients while they were clinically hyperthyroid and again when they were euthyroid following radioactive iodine therapy. Echocardiographic tracings of the septum and left ventricular posterior wall were digitized and analyzed to provide the maximum velocity of shortening and maximum velocity of lengthening. These velocities were normalized for left ventricular diastolic dimension. The left ventricular minor axis fractional shortening and the normalized maximum velocity of shortening were both increased during the hyperthyroid state. The normalized maximum velocity of lengthening, a measure of diastolic left ventricular function, was also increased during the hyperthyroid state when compared to the euthyroid state. The preejection period index and the preejection period/left ventricular ejection time ratio were lower when the patients were hyperthyroid than when they were euthyroid. These data confirm the increased inotropic state and demonstrated increased diastolic relaxation velocities of the hyperthyroid left ventricle

  15. Roll-Axis Hydrofluidic Stability Augmentation System Development

    Science.gov (United States)

    1975-09-01

    lifi .1035 SW 30 left for znro time delay - r Ight for other. 17 Preceding page Hank Recordings of the simulated aircraft performance to...DESIGN The analytical effort defined the gains and shaping networks required for the roll-axis damper system for the OH-58A helicopter, and the...Shaping Networks Usually a combination of resistors and capacitors (bellows) is designed to provide the following functions: a) b) 3.1.4 1 Lag

  16. Relation between the left ventricular mass and the left coronary artery dimensions as determined by 16-channel multidetector CT: comparison between the normotensive group and the hypertensive group

    International Nuclear Information System (INIS)

    Kang, Doo Kyung; Park, Kyung Joo; Tahk, Seung Jea; Kim, Sun Yong

    2006-01-01

    The purpose of this study is to determine the left ventricular mass (LVM) and the left coronary artery dimension and to investigate the relationship between the two values in the normotensive group and hypertensive group with using 16-channel multidetector CT (MDCT). Among the patients who underwent a CT coronary angiogram procedure using 16-channel MDCT at Ajou University Hospital from October 2004 to February 2005, 33 patient became the subjects of this study. These 33 patients showed normal findings without calcification or stenosis of the coronary arteries. The total volume of the left ventricular wall was calculated using work-in-progress cardiac CT reconstruction software. The LVM could then be directly calculated by multiplying the left ventricular muscle volume by the myocardial tissue density, which was assumed to be 1.05 g/cm 3 . The coronary diameter was measured by a fixed threshold method from the transverse reformation images obtained along the long-axis of each coronary artery. We calculated the cross-sectional area (CSA) of the coronary arteries from the equation of π D2/4 (D = diameter). Regression analysis was performed for the relationship between LVM and the left coronary artery dimensions with using a linear least-squares method. Comparison between the normotensive group and the hypertensive group was done using the Student test. The average LVM was 127.9 ± 36.2 g (mean ± standard deviation) and the average left ventricular mass index (LVMI) was 74.7 ± 15.5 g in this study population. The average diameter of the coronary arteries was 4.38 ± 0.69 mm for the left coronary artery. In all the subjects (n = 33, r = 0.67, ρ = 0.000) and the normotensive group (n = 21, r = 0.68, ρ = 0.000), the LVM was significantly correlated with the CSA of the left coronary artery, but not in the hypertensive group (n= 12, r = 0.57, ρ = 0.062). In the hypertensive group, the CSA of the left coronary arteries per 100 g of muscle mass tended to decrease as

  17. Assessment of left ventricular mechanical dyssynchrony in left bundle branch block canine model: Comparison between cine and tagged MRI.

    Science.gov (United States)

    Saporito, Salvatore; van Assen, Hans C; Houthuizen, Patrick; Aben, Jean-Paul M M; Strik, Marc; van Middendorp, Lars B; Prinzen, Frits W; Mischi, Massimo

    2016-10-01

    To compare cine and tagged magnetic resonance imaging (MRI) for left ventricular dyssynchrony assessment in left bundle branch block (LBBB), using the time-to-peak contraction timing, and a novel approach based on cross-correlation. We evaluated a canine model dataset (n = 10) before (pre-LBBB) and after induction of isolated LBBB (post-LBBB). Multislice short-axis tagged and cine MRI images were acquired using a 1.5 T scanner. We computed contraction time maps by cross-correlation, based on the timing of radial wall motion and of circumferential strain. Finally, we estimated dyssynchrony as the standard deviation of the contraction time over the different regions of the myocardium. Induction of LBBB resulted in a significant increase in dyssynchrony (cine: 13.0 ± 3.9 msec for pre-LBBB, and 26.4 ± 5.0 msec for post-LBBB, P = 0.005; tagged: 17.1 ± 5.0 msec at for pre-LBBB, and 27.9 ± 9.8 msec for post-LBBB, P = 0.007). Dyssynchrony assessed by cine and tagged MRI were in agreement (r = 0.73, P = 0.0003); differences were in the order of time difference between successive frames of 20 msec (bias: -2.9 msec; limit of agreement: 10.1 msec). Contraction time maps were derived; agreement was found in the contraction patterns derived from cine and tagged MRI (mean difference in contraction time per segment: 3.6 ± 13.7 msec). This study shows that the proposed method is able to quantify dyssynchrony after induced LBBB in an animal model. Cine-assessed dyssynchrony agreed with tagged-derived dyssynchrony, in terms of magnitude and spatial direction. J. MAGN. RESON. IMAGING 2016;44:956-963. © 2016 International Society for Magnetic Resonance in Medicine.

  18. Does Side Make a Difference? Anatomical Differences Between the Left and Right Ureter.

    Science.gov (United States)

    Odegard, Stephen E; Abernethy, Melinda G; Mueller, Elizabeth R

    2015-01-01

    Seventy to eighty percent of iatrogenic ureteral injuries involve the left ureter. We sought to evaluate potential anatomical differences between the left and right ureters that may contribute to this discrepancy. A retrospective image review was undertaken of women who underwent computed tomography urograms between 2012 and 2013. The distance to the ureters from the midline was measured at the level of the sacral promontory (S1) and the cervix. Cervical deviation from the midline was measured, and distance between the cervix and ureters was calculated. The anterior-posterior distance between ureters was also measured. Ninety-five computed tomography urograms were analyzed. The mean age was 56 years (range, 23-92 years). Mean cervical deviation was 2.9 mm left of the midline (P = 0.028). The left ureter was 4.2 mm more lateral than the right at S1 and 2.7 mm more lateral at the cervix (P = 0.000 and 0.001). There was no significant difference when accounting for cervical deviation (P = 0.220). The left ureter was 1.9 mm more anterior than the right at the cervix (P = 0.012). Age, body mass index, and ethnicity did not affect the ureteral position. Based on midline measurements, the left ureter courses 2 to 4 mm more lateral and anterior than does the right ureter. The cervix is also positioned 2 to 4 mm to the left side, and as a result, the ureters are actually symmetric to the cervix. Although seemingly small, 2 to 4 mm is the width range of a Heaney clamp. These anatomic differences may be a contributing factor to the increase in ureteral injuries on the left side compared with the right.

  19. Deviating colostomy construction versus stent placement as bridge to surgery for malignant left-sided colonic obstruction.

    Science.gov (United States)

    Amelung, Femke J; Ter Borg, Frank; Consten, Esther C J; Siersema, Peter D; Draaisma, Werner A

    2016-12-01

    Acute colonic decompression using a deviating colostomy (DC) or a self-expandable metal stent (SEMS) has been shown to lead to fewer complications and permanent stomas compared to acute resection in elderly patients with malignant left-sided colonic obstruction (LSCO). However, no consensus exists on which decompression method is superior, especially in patients treated with curative intend. This retrospective study therefore aimed to compare both decompression methods in potentially curable LSCO patients. All LSCO patients treated with curative intent between 2004 and 2013 in two teaching hospitals were retrospectively identified. In one institution, a DC was the standard of care, whereas in the other all patients were treated with SEMS. In total, 88 eligible LSCO patients with limited disease and curative treatment options were included; 51 patients had a SEMS placed and 37 patients a DC constructed. All patients eventually underwent a subsequent elective resection. In sum, 235 patients were excluded due to benign or inoperable disease. No significant differences were found for hospital stay, morbidity, disease-free and overall survival and mortality. Major complications were seen in 13/51 (25.5 %) patients in the SEMS group and were mostly due to stent dysfunction (n = 7). Also, one stent-related perforation occurred. Major complications occurred in 4/37 (10.8 %) patients in the DC group, including abdominal sepsis (n = 3) and wound dehiscence (n = 1). Long-term complication rate was significantly higher in the DC group (29.7 vs. 9.8 %, p = 0.01), mainly due to a high incisional hernia rate. Fewer patients had a temporary colostomy following elective resection after SEMS placement (62.2 vs. 17.6 %, p colostomy rate was not significantly different. SEMS and DC are both effective decompression methods for curable LSCO patients with comparable short- and long-term oncological outcomes; however, more surgical procedures are performed after DC due to an

  20. Left-right symmetry breaking in mice by left-right dynein may occur via a biased chromatid segregation mechanism, without directly involving the Nodal gene

    Energy Technology Data Exchange (ETDEWEB)

    Sauer, Stephan; Klar, Amar J. S., E-mail: sauers@mail.nih.gov, E-mail: klara@mail.nih.gov [Gene Regulation and Chromosome Biology Laboratory, Frederick National Laboratory for Cancer Research, Frederick, MD (United States)

    2012-11-16

    Ever since cloning the classic iv (inversedviscerum) mutation identified the “left-right dynein” (lrd) gene in mice, most research on body laterality determination has focused on its function in motile cilia at the node embryonic organizer. This model is attractive, as it links chirality of cilia architecture to asymmetry development. However, lrd is also expressed in blastocysts and embryonic stem cells, where it was shown to bias the segregation of recombined sister chromatids away from each other in mitosis. These data suggested that lrd is part of a cellular mechanism that recognizes and selectively segregates sister chromatids based on their replication history: old “Watson” versus old “Crick” strands. We previously proposed that the mouse left-right axis is established via an asymmetric cell division prior to/or during gastrulation. In this model, left-right dynein selectively segregates epigenetically differentiated sister chromatids harboring a hypothetical “left-right axis development 1” (“lra1”) gene during the left-right axis establishing cell division. Here, asymmetry development would be ultimately governed by the chirality of the cytoskeleton and the DNA molecule. Our model predicts that randomization of chromatid segregation in lrd mutants should produce embryos with 25% situs solitus, 25% situs inversus, and 50% embryonic death due to heterotaxia and isomerism. Here we confirmed this prediction by using two distinct lrd mutant alleles. Other than lrd, thus far Nodal gene is the most upstream function implicated in visceral organs laterality determination. We next tested whether the Nodal gene constitutes the lra1 gene hypothesized in the model by testing mutant’s effect on 50% embryonic lethality observed in lrd mutants. Since Nodal mutation did not suppress lethality, we conclude that Nodal is not equivalent to the lra1 gene. In summary, we describe the origin of 50% lethality in lrd mutant mice not yet explained by any other

  1. Left-right symmetry breaking in mice by left-right dynein may occur via a biased chromatid segregation mechanism, without directly involving the Nodal gene

    International Nuclear Information System (INIS)

    Sauer, Stephan; Klar, Amar J. S.

    2012-01-01

    Ever since cloning the classic iv (inversedviscerum) mutation identified the “left-right dynein” (lrd) gene in mice, most research on body laterality determination has focused on its function in motile cilia at the node embryonic organizer. This model is attractive, as it links chirality of cilia architecture to asymmetry development. However, lrd is also expressed in blastocysts and embryonic stem cells, where it was shown to bias the segregation of recombined sister chromatids away from each other in mitosis. These data suggested that lrd is part of a cellular mechanism that recognizes and selectively segregates sister chromatids based on their replication history: old “Watson” versus old “Crick” strands. We previously proposed that the mouse left-right axis is established via an asymmetric cell division prior to/or during gastrulation. In this model, left-right dynein selectively segregates epigenetically differentiated sister chromatids harboring a hypothetical “left-right axis development 1” (“lra1”) gene during the left-right axis establishing cell division. Here, asymmetry development would be ultimately governed by the chirality of the cytoskeleton and the DNA molecule. Our model predicts that randomization of chromatid segregation in lrd mutants should produce embryos with 25% situs solitus, 25% situs inversus, and 50% embryonic death due to heterotaxia and isomerism. Here we confirmed this prediction by using two distinct lrd mutant alleles. Other than lrd, thus far Nodal gene is the most upstream function implicated in visceral organs laterality determination. We next tested whether the Nodal gene constitutes the lra1 gene hypothesized in the model by testing mutant’s effect on 50% embryonic lethality observed in lrd mutants. Since Nodal mutation did not suppress lethality, we conclude that Nodal is not equivalent to the lra1 gene. In summary, we describe the origin of 50% lethality in lrd mutant mice not yet explained by any other

  2. Left-right symmetry breaking in mice by left-right dynein may occur via a biased chromatid segregation mechanism, without directly involving the Nodal gene

    Directory of Open Access Journals (Sweden)

    Stephan eSauer

    2012-11-01

    Full Text Available Ever since cloning the classic iv mutation identified the ‘left-right dynein’ (lrd gene in mice, most research on body laterality determination has focused on its function in motile cilia at the node embryonic organizer. This model is attractive, as it links chirality of cilia architecture to asymmetry development. However, lrd is also expressed in blastocysts and embryonic stem cells, where it was shown to bias the segregation of recombined sister chromatids away from each other in mitosis. These data suggested that lrd is part of a cellular mechanism that recognizes and selectively segregates sister chromatids based on their replication history: old ‘Watson’ vs. old ‘Crick’ strands. We previously proposed that the mouse left-right axis is established via an asymmetric cell division prior to/or during gastrulation. In this model, left-right dynein selectively segregates epigenetically differentiated sister chromatids harboring a hypothetical ‘left-right axis development 1’ (‘lra1’ gene during the left-right axis establishing cell division. Here, asymmetry development would be ultimately governed by the chirality of the cytoskeleton and the DNA molecule. Our model predicts that randomization of chromatid segregation in lrd mutants should produce embryos with 25% situs solitus, 25% situs inversus, and 50% embryonic death due to heterotaxia and isomerism. Here we confirmed this prediction by using two distinct lrd mutant alleles. Other than lrd, thus far Nodal gene is the most upstream function implicated in visceral organs laterality determination. We next tested whether the Nodal gene constitutes the lra1 gene hypothesized in the model by testing mutant’s effect on 50% embryonic lethality observed in lrd mutants. Since Nodal mutation did not suppress lethality, we conclude that Nodal is not equivalent to the lra1 gene. In summary, we describe the origin of 50% lethality in lrd mutant mice not yet explained by any other

  3. Antihysteresis of perceived longitudinal body axis during continuous quasi-static whole-body rotation in the earth-vertical roll plane.

    Science.gov (United States)

    Tatalias, M; Bockisch, C J; Bertolini, G; Straumann, D; Palla, A

    2011-03-01

    Estimation of subjective whole-body tilt in stationary roll positions after rapid rotations shows hysteresis. We asked whether this phenomenon is also present during continuous quasi-static whole-body rotation and whether gravitational cues are a major contributing factor. Using a motorized turntable, 8 healthy subjects were rotated continuously about the earth-horizontal naso-occipital axis (earth-vertical roll plane) and the earth-vertical naso-occipital axis (earth-horizontal roll plane). In both planes, three full constant velocity rotations (2°/s) were completed in clockwise and counterclockwise directions (acceleration = 0.05°/s(2), velocity plateau reached after 40 s). Subjects adjusted a visual line along the perceived longitudinal body axis (pLBA) every 2 s. pLBA deviation from the longitudinal body axis was plotted as a function of whole-body roll position, and a sine function was fitted. At identical whole-body earth-vertical roll plane positions, pLBA differed depending on whether the position was reached by a rotation from upright or by passing through upside down. After the first 360° rotation, pLBA at upright whole-body position deviated significantly in the direction of rotation relative to pLBA prior to rotation initiation. This deviation remained unchanged after subsequent full rotations. In contrast, earth-horizontal roll plane rotations resulted in similar pLBA before and after each rotation cycle. We conclude that the deviation of pLBA in the direction of rotation during quasi-static earth-vertical roll plane rotations reflects static antihysteresis and might be a consequence of the known static hysteresis of ocular counterroll: a visual line that is perceived that earth-vertical is expected to be antihysteretic, if ocular torsion is hysteretic.

  4. Extremes of 2d Coulomb gas: universal intermediate deviation regime

    Science.gov (United States)

    Lacroix-A-Chez-Toine, Bertrand; Grabsch, Aurélien; Majumdar, Satya N.; Schehr, Grégory

    2018-01-01

    In this paper, we study the extreme statistics in the complex Ginibre ensemble of N × N random matrices with complex Gaussian entries, but with no other symmetries. All the N eigenvalues are complex random variables and their joint distribution can be interpreted as a 2d Coulomb gas with a logarithmic repulsion between any pair of particles and in presence of a confining harmonic potential v(r) \\propto r2 . We study the statistics of the eigenvalue with the largest modulus r\\max in the complex plane. The typical and large fluctuations of r\\max around its mean had been studied before, and they match smoothly to the right of the mean. However, it remained a puzzle to understand why the large and typical fluctuations to the left of the mean did not match. In this paper, we show that there is indeed an intermediate fluctuation regime that interpolates smoothly between the large and the typical fluctuations to the left of the mean. Moreover, we compute explicitly this ‘intermediate deviation function’ (IDF) and show that it is universal, i.e. independent of the confining potential v(r) as long as it is spherically symmetric and increases faster than \\ln r2 for large r with an unbounded support. If the confining potential v(r) has a finite support, i.e. becomes infinite beyond a finite radius, we show via explicit computation that the corresponding IDF is different. Interestingly, in the borderline case where the confining potential grows very slowly as v(r) ∼ \\ln r2 for r \\gg 1 with an unbounded support, the intermediate regime disappears and there is a smooth matching between the central part and the left large deviation regime.

  5. Accuracy of right and left ventricular functional assessment by short-axis vs axial cine steady-state free-precession magnetic resonance imaging: intrapatient correlation with main pulmonary artery and ascending aorta phase-contrast flow measurements.

    Science.gov (United States)

    James, Susan H; Wald, Rachel; Wintersperger, Bernd J; Jimenez-Juan, Laura; Deva, Djeven; Crean, Andrew M; Nguyen, Elsie; Paul, Narinder S; Ley, Sebastian

    2013-08-01

    The left ventricle (LV) is routinely assessed with cardiac magnetic resonance imaging (MRI) by using short-axis orientation; it remains unclear whether the right ventricle (RV) can also be adequately assessed in this orientation or whether dedicated axial orientation is required. We used phase-contrast (PC) flow measurements in the main pulmonary artery (MPA) and the ascending aorta (Aorta) as nonvolumetric standard of reference and compared RV and LV volumes in short-axis and axial orientations. A retrospective analysis identified 30 patients with cardiac MRI data sets. Patients underwent MRI (1.5 T or 3 T), with retrospectively gated cine steady-state free-precession in axial and short-axis orientations. PC flow analyses of MPA and Aorta were used as the reference measure of RV and LV output. There was a high linear correlation between MPA-PC flow and RV-stroke volume (SV) short axis (r = 0.9) and RV-SV axial (r = 0.9). Bland-Altman analysis revealed a mean offset of 1.4 mL for RV axial and -2.3 mL for RV-short-axis vs MPA-PC flow. There was a high linear correlation between Aorta-PC flow and LV-SV short-axis (r = 0.9) and LV-SV axial (r = 0.9). Bland-Altman analysis revealed a mean offset of 4.8 m for LV short axis and 7.0 mL for LV axial vs Aorta-PC flow. There was no significant difference (P = .6) between short-axis-LV SV and short-axis-RV SV. No significant impact of the slice acquisition orientation for determination of RV and LV stroke volumes was found. Therefore, cardiac magnetic resonance workflow does not need to be extended by an axial data set for patients without complex cardiac disease for assessment of biventricular function and volumes. Copyright © 2013 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  6. Global and Regional Left Ventricular Contractile Impairment In Patients With Wolff-Parkinson-White Syndrome

    Directory of Open Access Journals (Sweden)

    Sony Jacob

    2009-07-01

    Full Text Available Background: To assess regional systolic function and global contractile function in patients with WPW Syndrome.Method: Eleven cases with manifest Wolff-Parkinson-White (WPW syndrome in sinus rhythm were compared to 11 age matched controls. 2D strain analysis was performed and peak segmental radial strain (pRS values obtained from basal ventricular parasternal short-axis images (70 ± 5 frames/sec using a dedicated software package. Heterogeneity of radial strain pattern in six circumferential basal left ventricular segments was measured in terms of standard deviations of peak RS (SDpRS or range (difference between maximum and minimum peak RS i.e. RangepRS. Spectral Doppler (continuous wave measurements were acquired through the left ventricular outflow tract to determine Pre Ejection Period (PEP, Left Ventricular Ejection Time (LVET and measures of left ventricular systolic performance. Results: LV segmental radial strain was profoundly heterogeneous in WPW cases in contrast to fairly homogenous strain pattern in normal subjects. Wide SDpRS values 17.5 ± 8.9 vs 3.3 ± 1.4, p<0.001 and RangepRS 42.7 ± 20.8 vs.8.5 ± 3.6 , p<0.001 were observed among WPW and healthy subjects respectively. PEP (132.4 ± 14.7 vs 4.7 ± 0.5ms, p<0.001 and corrected PEP (76.1 ± 8.0 vs 2.7 ± 0.4ms, p<0.001 were significantly longer in WPW patients compared to controls. The PEP/LVET ratio was also significantly greater in WPW cohort (0.49 ± 0.04 vs. 0.28 ± 0.05, p <0.001 suggesting global systolic dysfunction. Conclusion: Patients with manifest preexcitation (predominantly those with right-sided pathways have regional and global contractile dysfunction resulting from aberrant impulse propagation inherent to the preexcited state.

  7. A four-axis hand controller for helicopter flight control

    Science.gov (United States)

    Demaio, Joe

    1993-01-01

    A proof-of-concept hand controller for controlling lateral and longitudinal cyclic pitch, collective pitch and tail rotor thrust was developed. The purpose of the work was to address problems of operator fatigue, poor proprioceptive feedback and cross-coupling of axes associated with many four-axis controller designs. The present design is an attempt to reduce cross-coupling to a level that can be controlled with breakout force, rather than to eliminate it entirely. The cascaded design placed lateral and longitudinal cyclic in their normal configuration. Tail rotor thrust was placed atop the cyclic controller. A left/right twisting motion with the wrist made the control input. The axis of rotation was canted outboard (clockwise) to minimize cross-coupling with the cyclic pitch axis. The collective control was a twist grip, like a motorcycle throttle. Measurement of the amount of cross-coupling involved in pure, single-axis inputs showed cross coupling under 10 percent of full deflection for all axes. This small amount of cross-coupling could be further reduced with better damping and force gradient control. Fatigue was not found to be a problem, and proprioceptive feedback was adequate for all flight tasks executed.

  8. Propagation of light in the lithium niobate crystal along directions close to an optical axis

    International Nuclear Information System (INIS)

    Volkov, V.V.; Egorova, G.A.; Lonskij, Eh.S.; Potapov, E.V.; Rakov, A.V.

    1978-01-01

    Theoretical and experimental results are given of studying some characteristics of electrooptical modulator from lithium niobate when propagating in it linear-polarized light in directions close to the optical axis, the electric field being applied along the X axis. It has been shown that an increase in an angle of deviation from the optical axis of a light beam passing in the crystal changes the value of the controlling voltage. This is accompanied by the rotation of the polarization plane and the change in the intensity of the light being passed. The methods have been proposed of increasing the modulator aperture, determining the main refraction indices and some electrooptical coefficients fo the lithium niobate crystal

  9. Optical properties of the c-axis oriented LiNbO3 thin film

    International Nuclear Information System (INIS)

    Shandilya, Swati; Sharma, Anjali; Tomar, Monika; Gupta, Vinay

    2012-01-01

    C-axis oriented Lithium Niobate (LiNbO 3 ) thin films have been deposited onto epitaxially matched (001) sapphire substrate using pulsed laser deposition technique. Structural and optical properties of the thin films have been studied using the X-ray diffraction (XRD) and UV–Visible spectroscopy respectively. Raman spectroscopy has been used to study the optical phonon modes and defects in the c-axis oriented LiNbO 3 thin films. XRD analysis indicates the presence of stress in the as-grown LiNbO 3 thin films and is attributed to the small lattice mismatch between LiNbO 3 and sapphire. Refractive index (n = 2.13 at 640 nm) of the (006) LiNbO 3 thin films was found to be slightly lower from the corresponding bulk value (n = 2.28). Various factors responsible for the deviation in the refractive index of (006) LiNbO 3 thin films from the corresponding bulk value are discussed and the deviation is mainly attributed to the lattice contraction due to the presence of stress in deposited film.

  10. Normal left ventricular mechanics by two-dimensional speckle-tracking echocardiography. Reference values in healthy adults.

    Science.gov (United States)

    Kocabay, Gonenc; Muraru, Denisa; Peluso, Diletta; Cucchini, Umberto; Mihaila, Sorina; Padayattil-Jose, Seena; Gentian, Denas; Iliceto, Sabino; Vinereanu, Dragos; Badano, Luigi P

    2014-08-01

    Two-dimensional speckle-tracking echocardiography is a novel tool to assess myocardial function. The purpose of this study was to evaluate left ventricular myocardial strain and rotation parameters by two-dimensional speckle-tracking echocardiography in a large group of healthy adults across a wide age range to establish their reference values and to assess the influence of age, sex, and hemodynamic factors. Transthoracic echocardiograms were acquired in 247 healthy volunteers (139 women, 44 years [standard deviation, 16 years old] (range, 18-80 years). We measured longitudinal, circumferential, and radial peak systolic strain values, and left ventricular rotation and twist. Average values of global longitudinal, radial, and circumferential strain were -21.5% (standard deviation, 2.0%), 40.1% (standard deviation, 11.8%) and -22.2% (standard deviation, 3.4%), respectively. Longitudinal strain was significantly more negative in women, whereas radial and circumferential strain and rotational parameters were similar in both sexes. Accordingly, lower limits of normality for the strain components were -16.9% in men and -18.5% in women for longitudinal strain, and -15.4% for circumferential and 24.6% for radial strain, irrespective of sex. Longitudinal strain values were more negative at the base than at apical segments. Mean rotational values were -6.9° (standard deviation, 3.5°) for the base, 13.0° (standard deviation, 6.5°) for apical rotation, and 20.0° (standard deviation, 7.3°) for net twist. We report the comprehensive assessment of normal myocardial deformation and rotational mechanics in a large cohort of healthy volunteers. We found that women have more negative longitudinal strain, accounting for their higher left ventricular ejection fraction. Availability of reference values for these parameters may foster their implementation in the clinical routine. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  11. The Distance Standard Deviation

    OpenAIRE

    Edelmann, Dominic; Richards, Donald; Vogel, Daniel

    2017-01-01

    The distance standard deviation, which arises in distance correlation analysis of multivariate data, is studied as a measure of spread. New representations for the distance standard deviation are obtained in terms of Gini's mean difference and in terms of the moments of spacings of order statistics. Inequalities for the distance variance are derived, proving that the distance standard deviation is bounded above by the classical standard deviation and by Gini's mean difference. Further, it is ...

  12. Comparison with Tilted Axis Cranking and particle rotor model for triaxial nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Ohtsubo, Shin-ichi; Shimizu, Yoshifumi R [Kyushu Univ., Fukuoka (Japan). Dept. of Physics

    1998-03-01

    An extension of the cranking model in such a way to allow a rotation axis to deviate from the principal axes of the deformed mean-field is a promising tool for the spectroscopic study of rapidly rotating nuclei. We have applied such a `Tilted Axis Cranking` (TAC) method to a simple system of one-quasiparticle coupled to a triaxial rotor and compared it with a particle-rotor coupling calculation in order to check whether the spin-orientation degrees of freedom can be well described within the mean-field approximation. The result shows that the TAC method gives a good approximation to observable quantities and it is a suitable method to understand the dynamical interplay between the collective and single-particle angular momenta. (author)

  13. Segmentation Using Symmetry Deviation

    DEFF Research Database (Denmark)

    Hollensen, Christian; Højgaard, L.; Specht, L.

    2011-01-01

    of the CT-scans into a single atlas. Afterwards the standard deviation of anatomical symmetry for the 20 normal patients was evaluated using non-rigid registration and registered onto the atlas to create an atlas for normal anatomical symmetry deviation. The same non-rigid registration was used on the 10...... hypopharyngeal cancer patients to find anatomical symmetry and evaluate it against the standard deviation of the normal patients to locate pathologic volumes. Combining the information with an absolute PET threshold of 3 Standard uptake value (SUV) a volume was automatically delineated. The overlap of automated....... The standard deviation of the anatomical symmetry, seen in figure for one patient along CT and PET, was extracted for normal patients and compared with the deviation from cancer patients giving a new way of determining cancer pathology location. Using the novel method an overlap concordance index...

  14. Large deviations and idempotent probability

    CERN Document Server

    Puhalskii, Anatolii

    2001-01-01

    In the view of many probabilists, author Anatolii Puhalskii''s research results stand among the most significant achievements in the modern theory of large deviations. In fact, his work marked a turning point in the depth of our understanding of the connections between the large deviation principle (LDP) and well-known methods for establishing weak convergence results.Large Deviations and Idempotent Probability expounds upon the recent methodology of building large deviation theory along the lines of weak convergence theory. The author develops an idempotent (or maxitive) probability theory, introduces idempotent analogues of martingales (maxingales), Wiener and Poisson processes, and Ito differential equations, and studies their properties. The large deviation principle for stochastic processes is formulated as a certain type of convergence of stochastic processes to idempotent processes. The author calls this large deviation convergence.The approach to establishing large deviation convergence uses novel com...

  15. When the Right (Drug) Should Be Left : Prenatal Drug Exposure and Heterotaxy Syndrome

    NARCIS (Netherlands)

    van Veenendaal, Nicole R.; Kusters, Cynthia D. J.; Oostra, Roelof-Jan; Bergman, Jorieke E. H.; Cobben, Jan-Maarten

    Background: Recent studies reported an association between prenatal propylthiouracil exposure and birth defects, including abnormal arrangement across the left-right body axis, suggesting an association with heterotaxy syndrome. Methods: This case-control and case-finding study used data from 1981

  16. Research on Relationship Among Internet-Addiction, Personality Traits and Mental Health of Urban Left-Behind Children

    Science.gov (United States)

    Ge, Ying; Se, Jun; Zhang, Jingfu

    2015-01-01

    Aim: In this research, we attempted at exploring the relationships among urban left-behind children’s internet-addiction, personality traits and mental health. Methods: In the form of three relevant questionnaires (Adolescent Pathological Internet Use Scale, Eysenck Personality Questionnaire, Children’s Edition in Chinese and Mental Health Test), 796 urban left-behind children in China were investigated, concerning internet-addiction, personality traits and mental health. Results: (1) The internet-addiction rate of urban left-behind children in China reached10.8%—a relatively high figure, with the rate among males higher than that among females. In terms of internet-addition salience, the figure of urban left-behind children was obviously higher than that of non-left-behind children. (2) In China, the personality deviation rate of the overall left-behind children was 15.36%; while the personality deviation rate of the internet-addicted urban left-behind children was 38.88%, a figure prominently higher than that of the non-addicted urban left-behind children group, with the rate among females higher than that among males. (3) The mental health problem rate of the overall urban left-behind children in China was 8.43%; while the rate of the internet-addicted urban left-behind children was 27.77%, a figure significantly higher than that of the non-addicted urban left-behind children. (4) There were significant relationships among internet-addiction, personality traits and mental health. The total score of internet-addiction and its related dimensions can serve as indicators of personality neuroticism, psychoticism and the total scores of mental health. PMID:25946911

  17. Deviation from Trajectory Detection in Vision based Robotic Navigation using SURF and Subsequent Restoration by Dynamic Auto Correction Algorithm

    Directory of Open Access Journals (Sweden)

    Ray Debraj

    2015-01-01

    Full Text Available Speeded Up Robust Feature (SURF is used to position a robot with respect to an environment and aid in vision-based robotic navigation. During the course of navigation irregularities in the terrain, especially in an outdoor environment may deviate a robot from the track. Another reason for deviation can be unequal speed of the left and right robot wheels. Hence it is essential to detect such deviations and perform corrective operations to bring the robot back to the track. In this paper we propose a novel algorithm that uses image matching using SURF to detect deviation of a robot from the trajectory and subsequent restoration by corrective operations. This algorithm is executed in parallel to positioning and navigation algorithms by distributing tasks among different CPU cores using Open Multi-Processing (OpenMP API.

  18. Regional ejection fraction: a quantitative radionuclide index of regional left ventricular performance

    International Nuclear Information System (INIS)

    Maddox, D.E.; Wynne, J.; Uren, R.; Parker, J.A.; Idoine, J.; Siegel, L.C.; Neill, J.M.; Cohn, P.F.; Holman, B.L.

    1979-01-01

    Left ventricular regional ejection fractions were derived from background-corrected, time-activity curves in 43 patients assessed by both gated equilibrium radionuclide angiocardiography and left ventricular contrast angiography. From a single, modified left anterior oblique projection, the regional change in background corrected counts was determined in each of three anatomic regions. The normal range for regional radionuclide ejection fraction was determined in 10 patients with normal contrast ventriculograms and without obstructive coronary artery disease at coronary arteriography. Regional ejection fraction was compared with percent segmental axis shortening and extent of akinetic segments in corresponding regions of the contrast ventriculogram. Radionuclide and roentgenographic methods were in agreement as to the presence or absence of abnormal wall motion in 83 of 99 left ventricular regions (84%) in 33 patients evaluated prospectively. Comparison of regional ejection fraction demonstrated significant differences between regions with roentgenographically determined normokinesis hypokinesis, and akinesis. We conclude that the left ventricular regional ejection fraction provides a reliable quantitative assessment of regional left ventricular performance

  19. SAMPLE STANDARD DEVIATION(s) CHART UNDER THE ASSUMPTION OF MODERATENESS AND ITS PERFORMANCE ANALYSIS

    OpenAIRE

    Kalpesh S. Tailor

    2017-01-01

    Moderate distribution proposed by Naik V.D and Desai J.M., is a sound alternative of normal distribution, which has mean and mean deviation as pivotal parameters and which has properties similar to normal distribution. Mean deviation (δ) is a very good alternative of standard deviation (σ) as mean deviation is considered to be the most intuitively and rationally defined measure of dispersion. This fact can be very useful in the field of quality control to construct the control limits of the c...

  20. Left ventricular twist and circumferential strain in dogs with myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Zois, Nora Elisabeth; Olsen, N. T.; Moesgaard, S. G.

    2013-01-01

    During the cardiac cycle, the ventricle undergoes a twisting motion because of the oblique orientation of the left ventricular (LV) myofibers. This can be quantified by speckle-tracking echocardiography (STE). In mitral regurgitation (MR) in humans, the short axis deformation has been suggested...

  1. Optical properties of the c-axis oriented LiNbO{sub 3} thin film

    Energy Technology Data Exchange (ETDEWEB)

    Shandilya, Swati; Sharma, Anjali [Department of Physics and Astrophysics, University of Delhi, Delhi-110007 (India); Tomar, Monika [Miranda House, University of Delhi, Delhi 110007 (India); Gupta, Vinay, E-mail: drguptavinay@gmail.com [Department of Physics and Astrophysics, University of Delhi, Delhi-110007 (India)

    2012-01-01

    C-axis oriented Lithium Niobate (LiNbO{sub 3}) thin films have been deposited onto epitaxially matched (001) sapphire substrate using pulsed laser deposition technique. Structural and optical properties of the thin films have been studied using the X-ray diffraction (XRD) and UV-Visible spectroscopy respectively. Raman spectroscopy has been used to study the optical phonon modes and defects in the c-axis oriented LiNbO{sub 3} thin films. XRD analysis indicates the presence of stress in the as-grown LiNbO{sub 3} thin films and is attributed to the small lattice mismatch between LiNbO{sub 3} and sapphire. Refractive index (n = 2.13 at 640 nm) of the (006) LiNbO{sub 3} thin films was found to be slightly lower from the corresponding bulk value (n = 2.28). Various factors responsible for the deviation in the refractive index of (006) LiNbO{sub 3} thin films from the corresponding bulk value are discussed and the deviation is mainly attributed to the lattice contraction due to the presence of stress in deposited film.

  2. 48 CFR 2001.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Individual deviations. 2001... Individual deviations. In individual cases, deviations from either the FAR or the NRCAR will be authorized... deviations clearly in the best interest of the Government. Individual deviations must be authorized in...

  3. 48 CFR 801.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Individual deviations. 801... Individual deviations. (a) Authority to authorize individual deviations from the FAR and VAAR is delegated to... nature of the deviation. (d) The DSPE may authorize individual deviations from the FAR and VAAR when an...

  4. Tl scintiscanning hemodynamics and left ventricular kinetics in patients to be suspected of myocardial sarcoidosis

    International Nuclear Information System (INIS)

    Schaedel, H.; Kirsten, D.; Strauss, H.J.; Haenselt, V.; Schmidt, H.; Gottschild, D.; Zinner, G.

    1985-01-01

    The cardiological examination of 22 patients to be suspected of heart sarcoidosis (histologically established sarcoidosis, heart rhythm disturbances, cardiomegaly) has revealed thallium scan defects in 20 patients at rest and during exercise. In 19 patients pathologic left heart wall motions established by levocardiography applying the half axis method were found. The number of pathologic half axis shortenings correlated with ejection fraction, but not with left ventricular enddiastolic pressure and volume index, resp. Coronary heart disease could not be found by coronarography in any case. Myocardial biopsy did not show myocarditis. Cardiomyopathies, other specific heart muscle diseases or rheumatic myocarditis could not be excluded as causes of the results mentioned above. The follow-up examinations of the patients will give more detailed information on the etiology of the pathologic cardiac findings. (author)

  5. Influence of slice thickness on the determination of left ventricular wall thickness and dimension by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ohnishi, Shusaku; Fukui, Sugao; Atsumi, Chisato and others

    1989-02-01

    Wall thickness of the ventricular septum and left ventricle, and left ventricular cavity dimension were determined on magnetic resonance (MR) images with slices 5 mm and 10 mm in thickness. Subjects were 3 healthy volunteers and 7 patients with hypertension (4), hypertrophic cardiomyopathy (one) or valvular heart disease (2). In visualizing the cardiac structures such as left ventricular papillary muscle and right and left ventricles, 5 mm-thick images were better than 10 mm-thick images. Edges of ventricular septum and left ventricular wall were more clearly visualized on 5 mm-thick images than 10 mm-thick images. Two mm-thick MR images obtained from 2 patients yielded the most excellent visualization in end-systole, but failed to reveal cardiac structures in detail in end-diastole. Phantom studies revealed no significant differences in image quality of 10 mm and 5 mm in thickness in the axial view 80 degree to the long axis. In the axial view 45 degree to the long axis, 10 mm-thick images were inferior to 5 mm-thick images in detecting the edge of the septum and the left ventricular wall. These results indicate that the selection of slice thickness is one of the most important determinant factors in the measurement of left ventricular wall thickness and cavity dimension. (Namekawa, K).

  6. Influence of slice thickness on the determination of left ventricular wall thickness and dimension by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Ohnishi, Shusaku; Fukui, Sugao; Atsumi, Chisato

    1989-01-01

    Wall thickness of the ventricular septum and left ventricle, and left ventricular cavity dimension were determined on magnetic resonance (MR) images with slices 5 mm and 10 mm in thickness. Subjects were 3 healthy volunteers and 7 patients with hypertension (4), hypertrophic cardiomyopathy (one) or valvular heart disease (2). In visualizing the cardiac structures such as left ventricular papillary muscle and right and left ventricles, 5 mm-thick images were better than 10 mm-thick images. Edges of ventricular septum and left ventricular wall were more clearly visualized on 5 mm-thick images than 10 mm-thick images. Two mm-thick MR images obtained from 2 patients yielded the most excellent visualization in end-systole, but failed to reveal cardiac structures in detail in end-diastole. Phantom studies revealed no significant differences in image quality of 10 mm and 5 mm in thickness in the axial view 80 degree to the long axis. In the axial view 45 degree to the long axis, 10 mm-thick images were inferior to 5 mm-thick images in detecting the edge of the septum and the left ventricular wall. These results indicate that the selection of slice thickness is one of the most important determinant factors in the measurement of left ventricular wall thickness and cavity dimension. (Namekawa, K)

  7. Detecting deviating behaviors without models

    NARCIS (Netherlands)

    Lu, X.; Fahland, D.; van den Biggelaar, F.J.H.M.; van der Aalst, W.M.P.; Reichert, M.; Reijers, H.A.

    2016-01-01

    Deviation detection is a set of techniques that identify deviations from normative processes in real process executions. These diagnostics are used to derive recommendations for improving business processes. Existing detection techniques identify deviations either only on the process instance level

  8. Preliminary study of left ventricular cavity-to-myocardial count ratio. A new parameter for left ventricular function

    International Nuclear Information System (INIS)

    Zhou Ying; Qu Wanying; Zhu Ming; Gao Wenping; Zhao Hongshan

    1995-01-01

    A new simple quantitative parameter, left ventricular cavity-to-myocardial count ratio (C/M ratio) was suggested and compared with LVEF to assess its reliability and clinical value. Of 220 patients in the study, 102 had both exercise 99m Tc-MIBI myocardial SPECT imaging and resting radionuclide ventriculography, another 118 patients had both rest 99m Tc-MIBI myocardial SPECT imaging and rest radionuclide ventriculography, 740 MBq of 99m Tc-MIBI was injected intravenously. Both the exercise and rest C/M ratio were determined on short-axis tomograms and LVEF were calculated from radionuclide ventriculography. The correlation between LVEF and the C/M (exercise and rest) was analyzed. There was a positive linear correlation between LVEF measured by ventriculography and both C/M exercise ratio (r = 0.6964) and C/M rest ratio (r = 0.6995). The sensitivity of C/M exercise and rest ratio for detecting patients with left ventricular dysfunction is 71.9%, 68.6%; the specificity is 92.9%, 97.0%; the accuracy is 86.3%, 84.7% respectively. C/M ratio can accurately identify patients with CAD who have resting left ventricular dysfunction. It was highly reproducible, reliable and useful in clinical diagnosis

  9. Characterization of cardiac quiescence from retrospective cardiac computed tomography using a correlation-based phase-to-phase deviation measure

    Energy Technology Data Exchange (ETDEWEB)

    Wick, Carson A.; McClellan, James H. [School of Electrical and Computer Engineering, Georgia Institute of Technology, 777 Atlantic Drive Northwest, Atlanta, Georgia 30332 (United States); Arepalli, Chesnal D. [Department of Radiology, University of British Columbia, 3350-950 West 10th Avenue, Vancouver, British Columbia V5Z 4E3 (Canada); Auffermann, William F.; Henry, Travis S. [Department of Radiology and Imaging Sciences, Emory University, Division of Cardiothoracic Imaging, 1364 Clifton Road Northeast, Suite 309, Atlanta, Georgia 30322 (United States); Khosa, Faisal [Department of Radiology and Imaging Sciences, Emory University, Division of Emergency Radiology, 550 Peachtree Street Northeast, Atlanta, Georgia 30308 (United States); Coy, Adam M. [School of Medicine, Emory University, 100 Woodruff Circle, Atlanta, Georgia 30322 (United States); Tridandapani, Srini, E-mail: stridan@emory.edu [Department of Radiology and Imaging Sciences, Emory University, Winship Cancer Institute, 1701 Uppergate Drive Northeast, Suite 5018, Atlanta, Georgia 30322 and School of Electrical and Computer Engineering, Georgia Institute of Technology, 777 Atlantic Drive Northwest, Atlanta, Georgia 30332 (United States)

    2015-02-15

    Purpose: Accurate knowledge of cardiac quiescence is crucial to the performance of many cardiac imaging modalities, including computed tomography coronary angiography (CTCA). To accurately quantify quiescence, a method for detecting the quiescent periods of the heart from retrospective cardiac computed tomography (CT) using a correlation-based, phase-to-phase deviation measure was developed. Methods: Retrospective cardiac CT data were obtained from 20 patients (11 male, 9 female, 33–74 yr) and the left main, left anterior descending, left circumflex, right coronary artery (RCA), and interventricular septum (IVS) were segmented for each phase using a semiautomated technique. Cardiac motion of individual coronary vessels as well as the IVS was calculated using phase-to-phase deviation. As an easily identifiable feature, the IVS was analyzed to assess how well it predicts vessel quiescence. Finally, the diagnostic quality of the reconstructed volumes from the quiescent phases determined using the deviation measure from the vessels in aggregate and the IVS was compared to that from quiescent phases calculated by the CT scanner. Three board-certified radiologists, fellowship-trained in cardiothoracic imaging, graded the diagnostic quality of the reconstructions using a Likert response format: 1 = excellent, 2 = good, 3 = adequate, 4 = nondiagnostic. Results: Systolic and diastolic quiescent periods were identified for each subject from the vessel motion calculated using the phase-to-phase deviation measure. The motion of the IVS was found to be similar to the aggregate vessel (AGG) motion. The diagnostic quality of the coronary vessels for the quiescent phases calculated from the aggregate vessel (P{sub AGG}) and IVS (P{sub IV} {sub S}) deviation signal using the proposed methods was comparable to the quiescent phases calculated by the CT scanner (P{sub CT}). The one exception was the RCA, which improved for P{sub AGG} for 18 of the 20 subjects when compared to P

  10. Low-mass right-handed gauge bosons, manifest left-right symmetry, and the K/sub L/-K/sub s/ mass difference

    International Nuclear Information System (INIS)

    Datta, A.; Raychaudhuri, A.

    1983-01-01

    We calculate the K/sub L/-K/sub S/ mass difference in left-right-symmetric models with four quarks. It is found that a low right-handed mass scale requires strong deviations from manifest left-right symmetry

  11. The A/P axis in echinoderm ontogeny and evolution: evidence from fossils and molecules

    Science.gov (United States)

    Peterson, K. J.; Arenas-Mena, C.; Davidson, E. H.

    2000-01-01

    Even though echinoderms are members of the Bilateria, the location of their anterior/posterior axis has remained enigmatic. Here we propose a novel solution to the problem employing three lines of evidence: the expression of a posterior class Hox gene in the coeloms of the nascent adult body plan within the larva; the anatomy of certain early fossil echinoderms; and finally the relation between endoskeletal plate morphology and the associated coelomic tissues. All three lines of evidence converge on the same answer, namely that the location of the adult mouth is anterior, and the anterior/posterior axis runs from the mouth through the adult coelomic compartments. This axis then orients the animal such that there is but a single plane of symmetry dividing the animal into left and right halves. We tentatively hypothesize that this plane of symmetry is positioned along the dorsal/ventral axis. These axis identifications lead to the conclusion that the five ambulacra are not primary body axes, but instead are outgrowths from the central anterior/posterior axis. These identifications also shed insight into several other evolutionary mysteries of various echinoderm clades such as the independent evolution of bilateral symmetry in irregular echinoids, but do not elucidate the underlying mechanisms of the adult coelomic architecture.

  12. Laterotopic representation of left-right information onto the dorso-ventral axis of a zebrafish midbrain target nucleus.

    Science.gov (United States)

    Aizawa, Hidenori; Bianco, Isaac H; Hamaoka, Takanori; Miyashita, Toshio; Uemura, Osamu; Concha, Miguel L; Russell, Claire; Wilson, Stephen W; Okamoto, Hitoshi

    2005-02-08

    The habenulae are part of an evolutionarily highly conserved limbic-system conduction pathway that connects telencephalic nuclei to the interpeduncular nucleus (IPN) of the midbrain . In zebrafish, unilateral activation of the Nodal signaling pathway in the left brain specifies the laterality of the asymmetry of habenular size . We show "laterotopy" in the habenulo-interpeduncular projection in zebrafish, i.e., the stereotypic, topographic projection of left-sided habenular axons to the dorsal region of the IPN and of right-sided habenular axons to the ventral IPN. This asymmetric projection is accounted for by a prominent left-right (LR) difference in the size ratio of the medial and lateral habenular sub-nuclei, each of which specifically projects either to ventral or dorsal IPN targets. Asymmetric Nodal signaling directs the orientation of laterotopy but is dispensable for the establishment of laterotopy itself. Our results reveal a mechanism by which information distributed between left and right sides of the brain can be transmitted bilaterally without loss of LR coding, which may play a crucial role in functional lateralization of the vertebrate brain .

  13. 48 CFR 1501.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Individual deviations. 1501.403 Section 1501.403 Federal Acquisition Regulations System ENVIRONMENTAL PROTECTION AGENCY GENERAL GENERAL Deviations 1501.403 Individual deviations. Requests for individual deviations from the FAR and the...

  14. Quantitative evaluations of left ventricular function obtained by electrocardiographically-gated magnetic resonance imaging

    International Nuclear Information System (INIS)

    Takeda, Tohru; Iida, Kaname; Sugishita, Yasuro; Anno, Izumi; Akisada, Masayoshi; Matsuda, Mitsuo; Akatsuka, Takao; Koseki, Susumu.

    1989-01-01

    Using electrocardiographically-gated magnetic resonance imaging, regional cardiac function was evaluated in 12 normal volunteers and in 10 cases of old myocardial infarction. The optimal short axis of the left ventricle was selected at the chordae tendineae level. The left ventricle was divided into 12 segments using a computer-aided system, and percentile shortening fraction (%SF) and percentile wall thickening (%WT) were calculated in each segment by the fixed coordinate method. In the normal volunteers, heterogeneity of both %FS and %WT was observed, ranging from 25±13% and 37±13%, respectively in the septal segment, to 49±13% and 60±21%, respectively in the posterior segment. In the cases of myocardial infarction, decreased %FS and %WT were detected at the affected regions. The abnormal regions revealed by %WT tended to be narrower than those revealed by %FS. Thus the MR technique at the optimal axis may be useful for quantitative evaluations of regional cardiac function. (author)

  15. 48 CFR 2401.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Individual deviations. 2401... DEVELOPMENT GENERAL FEDERAL ACQUISITION REGULATION SYSTEM Deviations 2401.403 Individual deviations. In individual cases, proposed deviations from the FAR or HUDAR shall be submitted to the Senior Procurement...

  16. INDICATIVE MODEL OF DEVIATIONS IN PROJECT

    Directory of Open Access Journals (Sweden)

    Олена Борисівна ДАНЧЕНКО

    2016-02-01

    Full Text Available The article shows the process of constructing the project deviations indicator model. It based on a conceptual model of project deviations integrated management (PDIM. During the project different causes (such as risks, changes, problems, crises, conflicts, stress lead to deviations of integrated project indicators - time, cost, quality, and content. For a more detailed definition of where in the project deviations occur and how they are dangerous for the whole project, it needs to develop an indicative model of project deviations. It allows identifying the most dangerous deviations that require PDIM. As a basis for evaluation of project's success has been taken famous model IPMA Delta. During the evaluation, IPMA Delta estimated project management competence of organization in three modules: I-Module ("Individuals" - a self-assessment personnel, P-module ("Projects" - self-assessment of projects and/or programs, and O-module ("Organization" - used to conduct interviews with selected people during auditing company. In the process of building an indicative model of deviations in the project, the first step is the assessment of project management in the organization by IPMA Delta. In the future, built cognitive map and matrix of system interconnections of the project, which conducted simulations and built a scale of deviations for the selected project. They determined a size and place of deviations. To identify the detailed causes of deviations in the project management has been proposed to use the extended system of indicators, which is based on indicators of project management model Project Excellence. The proposed indicative model of deviations in projects allows to estimate the size of variation and more accurately identify the place of negative deviations in the project and provides the project manager information for operational decision making for the management of deviations in the implementation of the project

  17. 48 CFR 1301.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Individual deviations... DEPARTMENT OF COMMERCE ACQUISITION REGULATIONS SYSTEM Deviations From the FAR 1301.403 Individual deviations. The designee authorized to approve individual deviations from the FAR is set forth in CAM 1301.70. ...

  18. 48 CFR 301.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Individual deviations. 301... ACQUISITION REGULATION SYSTEM Deviations From the FAR 301.403 Individual deviations. Contracting activities shall prepare requests for individual deviations to either the FAR or HHSAR in accordance with 301.470. ...

  19. 48 CFR 1201.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Individual deviations... FEDERAL ACQUISITION REGULATIONS SYSTEM 70-Deviations From the FAR and TAR 1201.403 Individual deviations... Executive Service (SES) official or that of a Flag Officer, may authorize individual deviations (unless (FAR...

  20. A New, Adaptable, Optical High-Resolution 3-Axis Sensor

    Directory of Open Access Journals (Sweden)

    Niels Buchhold

    2017-01-01

    Full Text Available This article presents a new optical, multi-functional, high-resolution 3-axis sensor which serves to navigate and can, for example, replace standard joysticks in medical devices such as electric wheelchairs, surgical robots or medical diagnosis devices. A light source, e.g., a laser diode, is affixed to a movable axis and projects a random geometric shape on an image sensor (CMOS or CCD. The downstream microcontroller’s software identifies the geometric shape’s center, distortion and size, and then calculates x, y, and z coordinates, which can be processed in attached devices. Depending on the image sensor in use (e.g., 6.41 megapixels, the 3-axis sensor features a resolution of 1544 digits from right to left and 1038 digits up and down. Through interpolation, these values rise by a factor of 100. A unique feature is the exact reproducibility (deflection to coordinates and its precise ability to return to its neutral position. Moreover, optical signal processing provides a high level of protection against electromagnetic and radio frequency interference. The sensor is adaptive and adjustable to fit a user’s range of motion (stroke and force. This recommendation aims to optimize sensor systems such as joysticks in medical devices in terms of safety, ease of use, and adaptability.

  1. Association analyses of depression and genes in the hypothalamus-pituitary-adrenal axis

    DEFF Research Database (Denmark)

    Buttenschøn, Henriette Nørmølle; Krogh, Jesper; Nielsen, Marit Nyholm

    2017-01-01

    OBJECTIVE: Dysregulation of the hypothalamic-pituitary-adrenal (HPA) axis has been reported in depression. The aim was to investigate the potential association between depression and seven genes regulating or interfering with the HPA axis, including the gene encoding angiotensin converting enzyme......) was investigated. RESULTS: After quality control, 68 genetic variants were left for analyses. Four of nine variants within ACE were nominally associated with depression and a gene-wise association was likewise observed. However, none of the SNPs located within AVP, CRH, CRHR1, CRHR2, FKBP5 or NC3C1 were associated...... with depression. One nominally significant interaction, most likely due to chance, was identified. CONCLUSION: The results indicate that ACE could be a potential candidate gene for depression....

  2. 48 CFR 501.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Individual deviations. 501... Individual deviations. (a) An individual deviation affects only one contract action. (1) The Head of the Contracting Activity (HCA) must approve an individual deviation to the FAR. The authority to grant an...

  3. 48 CFR 401.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Individual deviations. 401... AGRICULTURE ACQUISITION REGULATION SYSTEM Deviations From the FAR and AGAR 401.403 Individual deviations. In individual cases, deviations from either the FAR or the AGAR will be authorized only when essential to effect...

  4. 48 CFR 2801.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Individual deviations. 2801... OF JUSTICE ACQUISITION REGULATIONS SYSTEM Deviations From the FAR and JAR 2801.403 Individual deviations. Individual deviations from the FAR or the JAR shall be approved by the head of the contracting...

  5. Visualizing the Sample Standard Deviation

    Science.gov (United States)

    Sarkar, Jyotirmoy; Rashid, Mamunur

    2017-01-01

    The standard deviation (SD) of a random sample is defined as the square-root of the sample variance, which is the "mean" squared deviation of the sample observations from the sample mean. Here, we interpret the sample SD as the square-root of twice the mean square of all pairwise half deviations between any two sample observations. This…

  6. Comparison of five-axis milling and rapid prototyping for implant surgical templates.

    Science.gov (United States)

    Park, Ji-Man; Yi, Tae-Kyoung; Koak, Jai-Young; Kim, Seong-Kyoon; Park, Eun-Jin; Heo, Seong-Joo

    2014-01-01

    This study aims to compare and evaluate the accuracy of surgical templates fabricated using coordinate synchronization processing with five-axis milling and design-related processing with rapid prototyping (RP). Master phantoms with 10 embedded gutta-percha cylinders hidden under artificial gingiva were fabricated and imaged using cone beam computed tomography. Vectors of the hidden cylinders were extracted and transferred to those of the planned implants through reverse engineering using virtual planning software. An RP-produced template was fabricated by stereolithography in photopolymer at the RP center according to planned data. Metal sleeves were bonded after holes were bored (group RP). For the milled template, milling coordinates were synchronized using the conversion process for the coordinate synchronization platform located on the model's bottom. Metal bushings were set on holes milled on the five-axis milling machine, on which the model was fixed through the coordinate synchronization plate, and the framework was constructed on the model using orthodontic resin (group CS). A computed tomography image was taken with templates firmly fixed on models using anchor pins (RP) or anchor screws (CS). The accuracy was analyzed via reverse engineering. Differences between the two groups were compared by repeated measures two-factor analysis. From the reverse-engineered image of the template on the experimental model, RP-produced templates showed significantly larger deviations than did milled surgical guides. Maximum deviations of the group RP were 1.58 mm (horizontal), 1.68 mm (vertical), and 8.51 degrees (angular); those of the group CS were 0.68 mm (horizontal), 0.41 mm (vertical), and 3.23 degrees (angular). A comparison of milling and RP template production methods showed that a vector-milled surgical guide had significantly smaller deviations than did an RP-produced template. The accuracy of computer-guided milled surgical templates was within the safety

  7. Left-right subtraction of brain CT

    International Nuclear Information System (INIS)

    Ishiguchi, Tsuneo; Sakuma, Sadayuki

    1986-01-01

    A new image-processing method to obtain a left-right subtraction image of CT was designed for the automated detection of abnormalities in brain CT. An original CT image was divided in two by a centerline. Then the right half of the image was subtracted from the left half by calculating the absorption value of the pixels on the symmetrical positions against the centerline. The mean and the standard deviation of the absorption value of the pixels in the subtraction image were used as parameters for analysis, and the detectability of abnormal CT findings was evaluated in 100 cases - 50 cases each with normal and abnormal CT. The presence of abnormalities could be diagnosed with a sensitivity of 86 %, a specificity of 90 %, and an overall accuracy of 88 % when the borderline of these parameters between normal and abnormal CT was set at the mean + 2SD in the normal group. As a further analysis, the CT image was subdivided into several areas from a functional or anatomical viewpoint, such as cerebral vascular territories, and the left-right subtraction image of each area was obtained. The possibilities of diagnosing the location of an abnormality and of detecting smaller lesions with this method were shown. Left-right subtraction was considered to be a useful method for the detection of asymmetric abnormalities in the automated diagnosis of brain CT. (author)

  8. Determination of left ventricular volume using gated blood pool tomography comparison with contrast ventriculography

    International Nuclear Information System (INIS)

    Lu Ping; Mo Lijun; Liu Xiujie

    1992-01-01

    48 patients with cardiac disease were studied with gated blood pool tomography to determine left ventricular volume at end diastole, end-systole and ejection fraction. The volumes were calculated from serial short-axis tomograms by multiplying the number of pixels and the known volume of each pixel. Excellent correlation was found between blood pool tomography and contrast ventriculographic volume. At end-diastole, r = 0.91 (P < 0.01); at end-systole, r = 0.95 (P < 0.01); for left ventricular ejection fraction, r 0.90 (P < 0.01). The results suggest that gated blood pool tomography is a promising noninvasive and direct method for measuring left ventricular volume

  9. Of Atkins and men: deviations from clinical definitions of mental retardation in death penalty cases.

    Science.gov (United States)

    Blume, John H; Johnson, Sheri Lynn; Seeds, Christopher

    2009-01-01

    Under Atkins v. Virginia, the Eighth Amendment exempts from execution individuals who meet the clinical definitions of mental retardation set forth by the American Association on Intellectual and Developmental Disabilities and the American Psychiatric Association. Both define mental retardation as significantly subaverage intellectual functioning accompanied by significant limitations in adaptive functioning, originating before the age of 18. Since Atkins, most jurisdictions have adopted definitions of mental retardation that conform to those definitions. But some states, looking often to stereotypes of persons with mental retardation, apply exclusion criteria that deviate from and are more restrictive than the accepted scientific and clinical definitions. These state deviations have the effect of excluding from Atkins's reach some individuals who plainly fall within the class it protects. This article focuses on the cases of Roger Cherry, Jeffrey Williams, Michael Stallings, and others, who represent an ever-growing number of individuals inappropriately excluded from Atkins. Left unaddressed, the state deviations discussed herein permit what Atkins does not: the death-sentencing and execution of some capital defendants who have mental retardation.

  10. Cortical motor representation of the rectus femoris does not differ between the left and right hemisphere.

    Science.gov (United States)

    Ward, Sarah; Bryant, Adam L; Pietrosimone, Brian; Bennell, Kim L; Clark, Ross; Pearce, Alan J

    2016-06-01

    Transcranial magnetic stimulation (TMS) involves non-invasive magnetic stimulation of the brain, and can be used to explore the corticomotor excitability and motor representations of skeletal muscles. However there is a lack of motor mapping studies in the lower limb and few conducted in healthy cohorts. The cortical motor representations of muscles can vary between individuals in terms of center position and area despite having a general localized region within the motor cortex. It is important to characterize the normal range for these variables in healthy cohorts to be able to evaluate changes in clinical populations. TMS was used in this cross-sectional study to assess the active motor threshold (AMT) and cortical representation area for rectus femoris in 15 healthy individuals (11M/4F 27.3±5.9years). No differences were found between hemispheres (Left vs. Right P=0.130) for AMT. In terms of y-axis center position no differences were found between hemispheres (Left vs. Right P=0.539), or for the x-axis center position (Left vs. Right P=0.076). Similarly, no differences in calculated area of the motor representation were found (Left vs. Right P=0.699) indicating symmetry between hemispheres. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. From Bench to Bedside: Translating the Prolactin/Vasoinhibin Axis

    Directory of Open Access Journals (Sweden)

    Jakob Triebel

    2017-12-01

    Full Text Available The prolactin/vasoinhibin axis defines an endocrine system, in which prolactin (PRL and vasoinhibins regulate blood vessel growth and function, the secretion of other hormones, inflammatory and immune processes, coagulation, and behavior. The core element of the PRL/vasoinhibin axis is the generation of vasoinhibins, which consists in the proteolytic cleavage of their precursor molecule PRL. Vasoinhibins can interact with multiple different partners to mediate their effects in various tissues and anatomical compartments, indicating their pleiotropic nature. Based on accumulating knowledge about the PRL/vasoinhibin axis, two clinical trials were initiated, in which vasoinhibin levels are the target of therapeutic interventions. One trial investigates the effect of levosulpiride, a selective dopamine D2-receptor antagonist, on retinal alterations in patients with diabetic macular edema and retinopathy. The rationale of this trial is that the levosulpiride-induced hyperprolactinemia resulting in increased retinal vasoinhibins could lead to beneficiary outcomes in terms of a vasoinhibin-mediated antagonization of diabetes-induced retinal alterations. Another trial investigated the effect of bromocriptine, a dopamine D2-receptor agonist, for the treatment of peripartum cardiomyopathy. The rationale of treatment with bromocriptine is the inhibition of vasoinhibin generation by substrate depletion to prevent detrimental effects on the myocardial microvascularization. The trial demonstrated that bromocriptine treatment was associated with a high rate of left ventricular recovery and low morbidity and mortality. Therapeutic interventions into the PRL/vasoinhibin axis bear the risk of side effects in the areas of blood coagulation, blood pressure, and alterations of the mental state.

  12. Assessment and validation of CT scanogram to compare per-operative and post-operative mechanical axis after navigated total knee replacement

    Science.gov (United States)

    Jain, Sunil

    2008-01-01

    Our objective was to assess and validate low-dose computed tomography (CT) scanogram as a post-operative imaging modality to measure the mechanical axis after navigated total knee replacement. A prospective study was performed to compare intra-operative and post-operative mechanical axis after navigated total knee replacements. All consecutive patients who underwent navigated total knee replacement between May and December 2006 were included. The intra-operative final axis was recorded, and post-operatively a CT scanogram of lower limbs was performed. The mechanical axis was measured and compared against the intra-operative measurement. There were 15 patients ranging in age from 57 to 80 (average 70) years. The average final intra-operative axis was 0.56° varus (4° varus to 1.5° valgus) and post-operative CT scanogram axis was 0.52° varus (3.1° varus to 1.8° valgus). The average deviation from final axes to CT scanogram axes was 0.12° valgus with a correlation coefficient of 0.9. Our study suggests that CT scanogram is an imaging modality with reasonable accuracy for measuring mechanical axis despite significantly low radiation. It also confirms a high level of correlation between intra-operative and post-operative mechanical axis after navigated total knee replacement. PMID:18696064

  13. Patterns of left ventricular remodeling among patients with essential and secondary hypertension.

    Science.gov (United States)

    Radulescu, Dan; Stoicescu, Laurentiu; Buzdugan, Elena; Donca, Valer

    2013-12-01

    High blood pressure causes left ventricular hypertrophy, which is a negative prognostic factor among hypertensive patients. To assess left ventricular geometric remodeling patterns in patients with essential hypertension or with hypertension secondary to parenchymal renal disease. We analyzed data from echocardiograms performed in 250 patients with essential hypertension (150 females) and 100 patients with secondary hypertension (60 females). The interventricular septum and the left ventricular posterior wall thickness were measured in the parasternal long-axis. Left ventricular mass was calculated using the Devereaux formula. The most common remodeling type in females and males with essential hypertension were eccentric and concentric left ventricular hypertrophy (cLVH), respectively. Among patients with secondary arterial hypertension, cLVH was most commonly observed in both genders. The prevalence of left ventricular hypertrophy was higher among patients with secondary hypertension. The left ventricular mass index and the relative left ventricular wall thickness were higher in males and also in the secondary hypertension group. Age, blood pressure values and the duration of hypertension, influenced remodeling patterns. We documented a higher prevalence of LVH among patients with secondary hypertension. The type of ventricular remodeling depends on gender, age, type of hypertension, blood pressure values and the duration of hypertension.

  14. Permanent Lateral Deviation and Stenosis of the Cervix in an Infertile Jennet.

    Science.gov (United States)

    Quartuccio, M; Marino, G; Mannarino, C; Cristarella, S

    2016-04-01

    Congenital abnormalities of the uterus and the cervix are rare in horses, often associated with infertility, despite normal ovarian activity and sexual behaviour. An abnormality of the cervix in a 5-year-old jennet with a history of infertility was described. Clinical and ultrasound examination of the genital tract showed a normal development of the uterus with regular cyclic activity in both the ovaries. Vaginoscopy revealed a normal development of the vagina and a cervix deviated on the left side of the vagina by a thick dorsoventral fold. The lateral deviation was permanent in any stage of oestrus cycle. Furthermore, the cervical os was narrow and digital penetration was not realizable. Using a 5-mm catheter, the full penetration was not possible even during oestrus; moreover, the inoculation of fluid could be revealed in uterus by ultrasound (fluid was not present before inoculation), demonstrating a minimal patency. An abnormal and permanent lateral displacement of a stenotic cervix was suspected as the primary cause of infertility in the jennet. © 2015 Blackwell Verlag GmbH.

  15. The reinterpretation of standard deviation concept

    OpenAIRE

    Ye, Xiaoming

    2017-01-01

    Existing mathematical theory interprets the concept of standard deviation as the dispersion degree. Therefore, in measurement theory, both uncertainty concept and precision concept, which are expressed with standard deviation or times standard deviation, are also defined as the dispersion of measurement result, so that the concept logic is tangled. Through comparative analysis of the standard deviation concept and re-interpreting the measurement error evaluation principle, this paper points o...

  16. Tbx6 regulates left/right patterning in mouse embryos through effects on nodal cilia and perinodal signaling.

    Directory of Open Access Journals (Sweden)

    Anna-Katerina Hadjantonakis

    Full Text Available BACKGROUND: The determination of left/right body axis during early embryogenesis sets up a developmental cascade that coordinates the development of the viscera and is essential to the correct placement and alignment of organ systems and vasculature. Defective left-right patterning can lead to congenital cardiac malformations, vascular anomalies and other serious health problems. Here we describe a novel role for the T-box transcription factor gene Tbx6 in left/right body axis determination in the mouse. RESULTS: Embryos lacking Tbx6 show randomized embryo turning and heart looping. Our results point to multiple mechanisms for this effect. First, Dll1, a direct target of Tbx6, is down regulated around the node in Tbx6 mutants and there is a subsequent decrease in nodal signaling, which is required for laterality determination. Secondly, in spite of a lack of expression of Tbx6 in the node, we document a profound effect of the Tbx6 mutation on the morphology and motility of nodal cilia. This results in the loss of asymmetric calcium signaling at the periphery of the node, suggesting that unidirectional nodal flow is disrupted. To carry out these studies, we devised a novel method for direct labeling and live imaging cilia in vivo using a genetically-encoded fluorescent protein fusion that labels tubulin, combined with laser point scanning confocal microscopy for direct visualization of cilia movement. CONCLUSIONS: We conclude that the transcription factor gene Tbx6 is essential for correct left/right axis determination in the mouse and acts through effects on notch signaling around the node as well as through an effect on the morphology and motility of the nodal cilia.

  17. Recognition of emotion in hemifaces presented to the left and right visual fields.

    Science.gov (United States)

    Wedding, D; Cyrus, P

    1986-09-01

    Thirty-two right-handed subjects (16 males and 16 females) participated in a choice reaction time experiment replicating two previous studies which demonstrated the superiority of the left hemisphere in rapidly identifying facial emotion as either positive or negative. Slides of hemifaces split along the vertical axis, showing either positive (happiness, surprise) or negative (anger, disgust, or sadness) affect were presented tachistoscopically to either the left or right visual field. A 2 X 2 X 2 mixed ANOVA revealed main effects for visual field and type of affect. In contrast to earlier studies which presented full face stimuli, presentation of hemifaces produced a strong left visual field advantage and, as expected, positive faces produced faster reaction times than negative faces.

  18. 48 CFR 3401.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Individual deviations. 3401.403 Section 3401.403 Federal Acquisition Regulations System DEPARTMENT OF EDUCATION ACQUISITION REGULATION GENERAL ED ACQUISITION REGULATION SYSTEM Deviations 3401.403 Individual deviations. An individual...

  19. 48 CFR 1.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Individual deviations. 1.403 Section 1.403 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Deviations from the FAR 1.403 Individual deviations. Individual...

  20. 48 CFR 2501.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Individual deviations. 2501.403 Section 2501.403 Federal Acquisition Regulations System NATIONAL SCIENCE FOUNDATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Deviations From the FAR 2501.403 Individual deviations. Individual...

  1. Fidelity deviation in quantum teleportation

    OpenAIRE

    Bang, Jeongho; Ryu, Junghee; Kaszlikowski, Dagomir

    2018-01-01

    We analyze the performance of quantum teleportation in terms of average fidelity and fidelity deviation. The average fidelity is defined as the average value of the fidelities over all possible input states and the fidelity deviation is their standard deviation, which is referred to as a concept of fluctuation or universality. In the analysis, we find the condition to optimize both measures under a noisy quantum channel---we here consider the so-called Werner channel. To characterize our resu...

  2. 48 CFR 601.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Individual deviations. 601.403 Section 601.403 Federal Acquisition Regulations System DEPARTMENT OF STATE GENERAL DEPARTMENT OF STATE ACQUISITION REGULATIONS SYSTEM Deviations from the FAR 601.403 Individual deviations. The...

  3. 48 CFR 201.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Individual deviations. 201.403 Section 201.403 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM... Individual deviations. (1) Individual deviations, except those described in 201.402(1) and paragraph (2) of...

  4. Assessment of ejection fraction of the right and left ventricles in patients with acute myocardial infarction by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Zhang, Youyi; Imai, Kamon; Araki, Yasushi; Nishino, Yukari; Saito, Satoshi; Ozawa, Yukio; Yasugi, Tadao

    1993-01-01

    Right and left ventricular function in acute myocardial infarction (AMI) was assessed by ECG-gated magnetic resonance imaging (MRI) in 64 patients and 8 volunteers. Five short axis images for intrinsic cardiac long-axis of the left ventricle were obtained at 9 msec and 309 msec after the R wave as end-diastole and end-systole. Right and left ventricular volumes were measured by Simpson's rule. The intraobserver variabilities in right and left ventricular ejection fraction (RVEF: r=0.94, LVEF: 0.89) were excellent. The interobserver variabilities in RVEF (r=0.61) and LVEF (r=0.77) were fair. LVEF, but not RVEF, was significantly reduced in patients with AMI. Among left ventricular dysfunction (LVEF≤40%) patients, 50% exhibited right ventricular dysfunction (RVEF≤40%). Among patients without left ventricular dysfunction, only 12% exhibited right ventricular dysfunction. In left ventricular and biventricular dysfunction compared with control, the left ventricular end-diastolic volume index increased (65±10 ml/m 2 , 68±12 ml/m 2 vs 54±8 ml/m 2 ), the end-systolic volume index increased (40±16 ml/m 2 , 43±7 ml/m 2 vs 18±1 ml/m 2 ), and the right ventricular end-diastolic volume index decreased (52±13 ml/m 2 , 53±20 ml/m 2 vs 65±8 ml/m 2 ). MRI can thus be used to assess ventricular systolic function. Since patients with left ventricular dysfunction revealed a high incidence of right ventricular dysfunction, an interaction between the left and right ventricles may occur in ventricular dysfunction. (author)

  5. MR image analysis: Longitudinal cardiac motion influences left ventricular measurements

    International Nuclear Information System (INIS)

    Berkovic, Patrick; Hemmink, Maarten; Parizel, Paul M.; Vrints, Christiaan J.; Paelinck, Bernard P.

    2010-01-01

    Background: Software for the analysis of left ventricular (LV) volumes and mass using border detection in short-axis images only, is hampered by through-plane cardiac motion. Therefore we aimed to evaluate software that involves longitudinal cardiac motion. Methods: Twenty-three consecutive patients underwent 1.5-Tesla cine magnetic resonance (MR) imaging of the entire heart in the long-axis and short-axis orientation with breath-hold steady-state free precession imaging. Offline analysis was performed using software that uses short-axis images (Medis MASS) and software that includes two-chamber and four-chamber images to involve longitudinal LV expansion and shortening (CAAS-MRV). Intraobserver and interobserver reproducibility was assessed by using Bland-Altman analysis. Results: Compared with MASS software, CAAS-MRV resulted in significantly smaller end-diastolic (156 ± 48 ml versus 167 ± 52 ml, p = 0.001) and end-systolic LV volumes (79 ± 48 ml versus 94 ± 52 ml, p < 0.001). In addition, CAAS-MRV resulted in higher LV ejection fraction (52 ± 14% versus 46 ± 13%, p < 0.001) and calculated LV mass (154 ± 52 g versus 142 ± 52 g, p = 0.004). Intraobserver and interobserver limits of agreement were similar for both methods. Conclusion: MR analysis of LV volumes and mass involving long-axis LV motion is a highly reproducible method, resulting in smaller LV volumes, higher ejection fraction and calculated LV mass.

  6. Deviations from excitation equilibrium in optically thick mercury arc plasmas

    International Nuclear Information System (INIS)

    Karabourniotis, D.; Couris, S.; Damelincourt, J.J.

    1989-01-01

    Up to date mercury arcs at pressure greater than 1 atm have been investigated as plasma systems in local thermodynamic equilibrium (LTE) state. These studies have been motivated by the applications of mercury arcs, e.g., in the lighting industry. The LTE-assumption simplifies the use of spectroscopic diagnostics and the performance of species-concentration calculations. A high pressure mercury arc of about 1 atm had been considered in two possibilities: excitation and gas temperatures are the same, the electron temperature is higher and excitation and electron temperatures are the same, the gas temperature is lower. Recent measurements in mercury arcs reveal the existence of severe departures from thermal equilibrium and suggest the absence of excitation equilibrium in the axis and in the periphery in such an arc. The deviation from equilibrium leads to complicated distributions, such that the system cannot be described correctly by any single temperature. This becomes quite complicated when plasma inhomogeneity and strong reabsorption of the radiation are present

  7. 48 CFR 3001.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Individual deviations... from the FAR and HSAR 3001.403 Individual deviations. Unless precluded by law, executive order, or other regulation, the HCA is authorized to approve individual deviation (except with respect to (FAR) 48...

  8. 48 CFR 1901.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Individual deviations. 1901.403 Section 1901.403 Federal Acquisition Regulations System BROADCASTING BOARD OF GOVERNORS GENERAL... Individual deviations. Deviations from the IAAR or the FAR in individual cases shall be authorized by the...

  9. Deviating From the Benchmarks

    DEFF Research Database (Denmark)

    Rocha, Vera; Van Praag, Mirjam; Carneiro, Anabela

    This paper studies three related questions: To what extent otherwise similar startups employ different quantities and qualities of human capital at the moment of entry? How persistent are initial human capital choices over time? And how does deviating from human capital benchmarks influence firm......, founders human capital, and the ownership structure of startups (solo entrepreneurs versus entrepreneurial teams). We then study the survival implications of exogenous deviations from these benchmarks, based on spline models for survival data. Our results indicate that (especially negative) deviations from...... the benchmark can be substantial, are persistent over time, and hinder the survival of firms. The implications may, however, vary according to the sector and the ownership structure at entry. Given the stickiness of initial choices, wrong human capital decisions at entry turn out to be a close to irreversible...

  10. Opposing nodal and BMP signals regulate left-right asymmetry in the sea urchin larva.

    Directory of Open Access Journals (Sweden)

    Yi-Jyun Luo

    Full Text Available Nodal and BMP signals are important for establishing left-right (LR asymmetry in vertebrates. In sea urchins, Nodal signaling prevents the formation of the rudiment on the right side. However, the opposing pathway to Nodal signaling during LR axis establishment is not clear. Here, we revealed that BMP signaling is activated in the left coelomic pouch, specifically in the veg2 lineage, but not in the small micromeres. By perturbing BMP activities, we demonstrated that BMP signaling is required for activating the expression of the left-sided genes and the formation of the left-sided structures. On the other hand, Nodal signals on the right side inhibit BMP signaling and control LR asymmetric separation and apoptosis of the small micromeres. Our findings show that BMP signaling is the positive signal for left-sided development in sea urchins, suggesting that the opposing roles of Nodal and BMP signals in establishing LR asymmetry are conserved in deuterostomes.

  11. Computer generation of random deviates

    International Nuclear Information System (INIS)

    Cormack, John

    1991-01-01

    The need for random deviates arises in many scientific applications. In medical physics, Monte Carlo simulations have been used in radiology, radiation therapy and nuclear medicine. Specific instances include the modelling of x-ray scattering processes and the addition of random noise to images or curves in order to assess the effects of various processing procedures. Reliable sources of random deviates with statistical properties indistinguishable from true random deviates are a fundamental necessity for such tasks. This paper provides a review of computer algorithms which can be used to generate uniform random deviates and other distributions of interest to medical physicists, along with a few caveats relating to various problems and pitfalls which can occur. Source code listings for the generators discussed (in FORTRAN, Turbo-PASCAL and Data General ASSEMBLER) are available on request from the authors. 27 refs., 3 tabs., 5 figs

  12. Method used to test the imaging consistency of binocular camera's left-right optical system

    Science.gov (United States)

    Liu, Meiying; Wang, Hu; Liu, Jie; Xue, Yaoke; Yang, Shaodong; Zhao, Hui

    2016-09-01

    To binocular camera, the consistency of optical parameters of the left and the right optical system is an important factor that will influence the overall imaging consistency. In conventional testing procedure of optical system, there lacks specifications suitable for evaluating imaging consistency. In this paper, considering the special requirements of binocular optical imaging system, a method used to measure the imaging consistency of binocular camera is presented. Based on this method, a measurement system which is composed of an integrating sphere, a rotary table and a CMOS camera has been established. First, let the left and the right optical system capture images in normal exposure time under the same condition. Second, a contour image is obtained based on the multiple threshold segmentation result and the boundary is determined using the slope of contour lines near the pseudo-contour line. Third, the constraint of gray level based on the corresponding coordinates of left-right images is established and the imaging consistency could be evaluated through standard deviation σ of the imaging grayscale difference D (x, y) between the left and right optical system. The experiments demonstrate that the method is suitable for carrying out the imaging consistency testing for binocular camera. When the standard deviation 3σ distribution of imaging gray difference D (x, y) between the left and right optical system of the binocular camera does not exceed 5%, it is believed that the design requirements have been achieved. This method could be used effectively and paves the way for the imaging consistency testing of the binocular camera.

  13. Global left ventricular function in cardiac CT. Evaluation of an automated 3D region-growing segmentation algorithm

    International Nuclear Information System (INIS)

    Muehlenbruch, Georg; Das, Marco; Hohl, Christian; Wildberger, Joachim E.; Guenther, Rolf W.; Mahnken, Andreas H.; Rinck, Daniel; Flohr, Thomas G.; Koos, Ralf; Knackstedt, Christian

    2006-01-01

    The purpose was to evaluate a new semi-automated 3D region-growing segmentation algorithm for functional analysis of the left ventricle in multislice CT (MSCT) of the heart. Twenty patients underwent contrast-enhanced MSCT of the heart (collimation 16 x 0.75 mm; 120 kV; 550 mAseff). Multiphase image reconstructions with 1-mm axial slices and 8-mm short-axis slices were performed. Left ventricular volume measurements (end-diastolic volume, end-systolic volume, ejection fraction and stroke volume) from manually drawn endocardial contours in the short axis slices were compared to semi-automated region-growing segmentation of the left ventricle from the 1-mm axial slices. The post-processing-time for both methods was recorded. Applying the new region-growing algorithm in 13/20 patients (65%), proper segmentation of the left ventricle was feasible. In these patients, the signal-to-noise ratio was higher than in the remaining patients (3.2±1.0 vs. 2.6±0.6). Volume measurements of both segmentation algorithms showed an excellent correlation (all P≤0.0001); the limits of agreement for the ejection fraction were 2.3±8.3 ml. In the patients with proper segmentation the mean post-processing time using the region-growing algorithm was diminished by 44.2%. On the basis of a good contrast-enhanced data set, a left ventricular volume analysis using the new semi-automated region-growing segmentation algorithm is technically feasible, accurate and more time-effective. (orig.)

  14. Investigation of the on-axis atom number density in the supersonic gas jet under high gas backing pressure by simulation

    Directory of Open Access Journals (Sweden)

    Guanglong Chen

    2015-10-01

    Full Text Available The supersonic gas jets from conical nozzles are simulated using 2D model. The on-axis atom number density in gas jet is investigated in detail by comparing the simulated densities with the idealized densities of straight streamline model in scaling laws. It is found that the density is generally lower than the idealized one and the deviation between them is mainly dependent on the opening angle of conical nozzle, the nozzle length and the gas backing pressure. The density deviation is then used to discuss the deviation of the equivalent diameter of a conical nozzle from the idealized deq in scaling laws. The investigation on the lateral expansion of gas jet indicates the lateral expansion could be responsible for the behavior of the density deviation. These results could be useful for the estimation of cluster size and the understanding of experimental results in laser-cluster interaction experiments.

  15. Zygotic LvBMP5-8 is required for skeletal patterning and for left-right but not dorsal-ventral specification in the sea urchin embryo.

    Science.gov (United States)

    Piacentino, Michael L; Chung, Oliver; Ramachandran, Janani; Zuch, Daniel T; Yu, Jia; Conaway, Evan A; Reyna, Arlene E; Bradham, Cynthia A

    2016-04-01

    Skeletal patterning in the sea urchin embryo requires coordinated signaling between the pattern-dictating ectoderm and the skeletogenic primary mesenchyme cells (PMCs); recent studies have begun to uncover the molecular basis for this process. Using an unbiased RNA-Seq-based screen, we have previously identified the TGF-ß superfamily ligand, LvBMP5-8, as a skeletal patterning gene in Lytechinus variegatus embryos. This result is surprising, since both BMP5-8 and BMP2/4 ligands have been implicated in sea urchin dorsal-ventral (DV) and left-right (LR) axis specification. Here, we demonstrate that zygotic LvBMP5-8 is required for normal skeletal patterning on the left side, as well as for normal PMC positioning during gastrulation. Zygotic LvBMP5-8 is required for expression of the left-side marker soxE, suggesting that LvBMP5-8 is required for left-side specification. Interestingly, we also find that LvBMP5-8 knockdown suppresses serotonergic neurogenesis on the left side. While LvBMP5-8 overexpression is sufficient to dorsalize embryos, we find that zygotic LvBMP5-8 is not required for normal DV specification or development. In addition, ectopic LvBMP5-8 does not dorsalize LvBMP2/4 morphant embryos, indicating that, in the absence of BMP2/4, BMP5-8 is insufficient to specify dorsal. Taken together, our data demonstrate that zygotic LvBMP5-8 signaling is essential for left-side specification, and for normal left-side skeletal and neural patterning, but not for DV specification. Thus, while both BMP2/4 and BMP5-8 regulate LR axis specification, BMP2/4 but not zygotic BMP5-8 regulates DV axis specification in sea urchin embryos. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Surgical Success Rates for Horizontal Concomitant Deviations According to the Type and Degree of Deviation

    Directory of Open Access Journals (Sweden)

    İhsan Çaça

    2004-01-01

    Full Text Available We evaluated the correlation with success rates and deviation type and degree inhorizontal concomitant deviations. 104 horizontal concomitan strabismus cases whowere operated in our clinic between January 1994 – December 2000 were included in thestudy. 56 cases undergone recession-resection procedure in the same eye 19 cases twomuscle recession and one muscle resection, 20 cases two muscle recession, 9 cases onlyone muscle recession. 10 ± prism diopter deviation in postoperative sixth monthexamination was accepted as surgical success.Surgical success rate was 90% and 89.3% in the cases with deviation angle of 15-30and 31-50 prism diopter respectively. Success rate was 78.9% if the angle was more than50 prism diopter. According to strabismus type when surgical success rate examined; inalternan esotropia 88.33%, in alternan exotropia 84.6%, in monocular esotropia 88%and in monocular exotropia 83.3% success was fixed. Statistically significant differencewas not found between strabismus type and surgical success rate. The binocular visiongaining rate was found as 51.8% after the treatment of cases.In strabismus surgery, preoperative deviation angle was found to be an effectivefactor on the success rate.

  17. VOLUMETRIC ERROR COMPENSATION IN FIVE-AXIS CNC MACHINING CENTER THROUGH KINEMATICS MODELING OF GEOMETRIC ERROR

    Directory of Open Access Journals (Sweden)

    Pooyan Vahidi Pashsaki

    2016-06-01

    Full Text Available Accuracy of a five-axis CNC machine tool is affected by a vast number of error sources. This paper investigates volumetric error modeling and its compensation to the basis for creation of new tool path for improvement of work pieces accuracy. The volumetric error model of a five-axis machine tool with the configuration RTTTR (tilting head B-axis and rotary table in work piece side A΄ was set up taking into consideration rigid body kinematics and homogeneous transformation matrix, in which 43 error components are included. Volumetric error comprises 43 error components that can separately reduce geometrical and dimensional accuracy of work pieces. The machining accuracy of work piece is guaranteed due to the position of the cutting tool center point (TCP relative to the work piece. The cutting tool is deviated from its ideal position relative to the work piece and machining error is experienced. For compensation process detection of the present tool path and analysis of the RTTTR five-axis CNC machine tools geometrical error, translating current position of component to compensated positions using the Kinematics error model, converting newly created component to new tool paths using the compensation algorithms and finally editing old G-codes using G-code generator algorithm have been employed.

  18. 14 CFR 21.609 - Approval for deviation.

    Science.gov (United States)

    2010-01-01

    ... deviation. (a) Each manufacturer who requests approval to deviate from any performance standard of a TSO shall show that the standards from which a deviation is requested are compensated for by factors or... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Approval for deviation. 21.609 Section 21...

  19. Entanglement transitions induced by large deviations

    Science.gov (United States)

    Bhosale, Udaysinh T.

    2017-12-01

    The probability of large deviations of the smallest Schmidt eigenvalue for random pure states of bipartite systems, denoted as A and B , is computed analytically using a Coulomb gas method. It is shown that this probability, for large N , goes as exp[-β N2Φ (ζ ) ] , where the parameter β is the Dyson index of the ensemble, ζ is the large deviation parameter, while the rate function Φ (ζ ) is calculated exactly. Corresponding equilibrium Coulomb charge density is derived for its large deviations. Effects of the large deviations of the extreme (largest and smallest) Schmidt eigenvalues on the bipartite entanglement are studied using the von Neumann entropy. Effect of these deviations is also studied on the entanglement between subsystems 1 and 2, obtained by further partitioning the subsystem A , using the properties of the density matrix's partial transpose ρ12Γ. The density of states of ρ12Γ is found to be close to the Wigner's semicircle law with these large deviations. The entanglement properties are captured very well by a simple random matrix model for the partial transpose. The model predicts the entanglement transition across a critical large deviation parameter ζ . Log negativity is used to quantify the entanglement between subsystems 1 and 2. Analytical formulas for it are derived using the simple model. Numerical simulations are in excellent agreement with the analytical results.

  20. A patient with mandibular deviation and 3 mandibular incisors treated with asymmetrically bent improved superelastic nickel-titanium alloy wires.

    Science.gov (United States)

    Ikeda, Yuhei; Kokai, Satoshi; Ono, Takashi

    2018-01-01

    Skeletal and dental discrepancies cause asymmetric malocclusions in orthodontic patients. It is difficult to achieve adequate functional occlusion and guidance in patients with congenital absence of a mandibular incisor due to the tooth-size discrepancy. Here, we describe the orthodontic treatment of a 22-year-old woman with an asymmetric Angle Class II malocclusion, mandibular deviation to the left, and 3 mandibular incisors. The anterior teeth and maxillary canines were crowded. We used an improved superelastic nickel-titanium alloy wire (Tomy International, Tokyo, Japan) to compensate for the asymmetric mandibular arch and an asymmetrically bent archwire to move the maxillary molars distally. A skeletal anchorage system provided traction for intermaxillary elastics, and extractions were not needed. We alleviated the crowding and created an ideal occlusion with proper overjet, overbite, and anterior guidance with Class I canine and molar relationships. This method of treatment with an asymmetrically bent nickel-titanium alloy wire provided proper Class I occlusion and anterior guidance despite the mandibular deviation to the left and 3 mandibular incisors, without the need for extractions. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  1. Magnetic resonance tissue phase mapping demonstrates altered left ventricular diastolic function in children with chronic kidney disease

    International Nuclear Information System (INIS)

    Gimpel, Charlotte; Pohl, Martin; Jung, Bernd A.; Jung, Sabine; Brado, Johannes; Odening, Katja E.; Schwendinger, Daniel; Burkhardt, Barbara; Geiger, Julia; Arnold, Raoul

    2017-01-01

    Echocardiographic examinations have revealed functional cardiac abnormalities in children with chronic kidney disease. To assess the feasibility of MRI tissue phase mapping in children and to assess regional left ventricular wall movements in children with chronic kidney disease. Twenty pediatric patients with chronic kidney disease (before or after renal transplantation) and 12 healthy controls underwent tissue phase mapping (TPM) to quantify regional left ventricular function through myocardial long (Vz) and short-axis (Vr) velocities at all 3 levels of the left ventricle. Patients and controls (age: 8 years - 20 years) were matched for age, height, weight, gender and heart rate. Patients had higher systolic blood pressure. No patient had left ventricular hypertrophy on MRI or diastolic dysfunction on echocardiography. Fifteen patients underwent tissue Doppler echocardiography, with normal z-scores for mitral early diastolic (V E ), late diastolic (V A ) and peak systolic (V S ) velocities. Throughout all left ventricular levels, peak diastolic Vz and Vr (cm/s) were reduced in patients: Vz base -10.6 ± 1.9 vs. -13.4 ± 2.0 (P < 0.0003), Vz mid -7.8 ± 1.6 vs. -11 ± 1.5 (P < 0.0001), Vz apex -3.8 ± 1.6 vs. -5.3 ± 1.6 (P = 0.01), Vr base -4.2 ± 0.8 vs. -4.9 ± 0.7 (P = 0.01), Vr mid -4.7 ± 0.7 vs. -5.4 ± 0.7 (P = 0.01), Vr apex -4.7 ± 1.4 vs. -5.6 ± 1.1 (P = 0.05). Tissue phase mapping is feasible in children and adolescents. Children with chronic kidney disease show significantly reduced peak diastolic long- and short-axis left ventricular wall velocities, reflecting impaired early diastolic filling. Thus, tissue phase mapping detects chronic kidney disease-related functional myocardial changes before overt left ventricular hypertrophy or echocardiographic diastolic dysfunction occurs. (orig.)

  2. Study of the Ultimate Error of the Axis Tolerance Feature and Its Pose Decoupling Based on an Area Coordinate System

    Directory of Open Access Journals (Sweden)

    Qungui Du

    2018-03-01

    Full Text Available Manufacturing error and assembly error should be taken into consideration during evaluation and analysis of accurate product performance in the design phase. Traditional tolerance analysis methods establish error propagation model based on dimension chains with tolerance values being regarded as error boundaries, and obtain the limit of target feature error through optimization methods or conducting statistical analysis with the tolerance domain being the boundary. As deviations of the tolerance feature (TF on degrees of freedom (DOF have coupling relations, accurate deviations on all DOF may not be obtained, even though these deviations constitute the basis for product performance analysis. Therefore, taking the widely used shaft-hole fit as an example, a pose decoupling model of the axis TF was proposed based on an area coordinate system. This model realized decoupling analysis of any pose of the axis TF within the tolerance domain. As proposed by the authors, by combining a tolerance analysis model based on tracking local coordinate systems, ultimate pose analysis of the closed-loop system, namely the target feature, as well as statistical analysis could be further implemented. This method contributed to analysis of true product performance with arbitrary error in the product design phase from the angle of tolerance, therefore, shortening the product research and development cycle. This method is demonstrated through applying it to a real-life example.

  3. Virtual machining considering dimensional, geometrical and tool deflection errors in three-axis CNC milling machines

    OpenAIRE

    Soori, Mohsen; Arezoo, Behrooz; Habibi, Mohsen

    2014-01-01

    Virtual manufacturing systems can provide useful means for products to be manufactured without the need of physical testing on the shop floor. As a result, the time and cost of part production can be decreased. There are different error sources in machine tools such as tool deflection, geometrical deviations of moving axis and thermal distortions of machine tool structures. Some of these errors can be decreased by controlling the machining process and environmental parameters. However other e...

  4. Virtual machining considering dimensional, geometrical and tool deflection errors in three-axis CNC milling machines

    OpenAIRE

    Soori, Mohsen; Arezoo, Behrooz; Habibi, Mohsen

    2016-01-01

    Virtual manufacturing systems can provide useful means for products to be manufactured without the need of physical testing on the shop floor. As a result, the time and cost of part production can be decreased. There are different error sources in machine tools such as tool deflection, geometrical deviations of moving axis and thermal distortions of machine tool structures. Some of these errors can be decreased by controlling the machining process and environmental parameters. However other e...

  5. 22 CFR 226.4 - Deviations.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Deviations. 226.4 Section 226.4 Foreign Relations AGENCY FOR INTERNATIONAL DEVELOPMENT ADMINISTRATION OF ASSISTANCE AWARDS TO U.S. NON-GOVERNMENTAL ORGANIZATIONS General § 226.4 Deviations. The Office of Management and Budget (OMB) may grant exceptions for...

  6. Direct generation of linearly polarized single photons with a deterministic axis in quantum dots

    Directory of Open Access Journals (Sweden)

    Wang Tong

    2017-07-01

    Full Text Available We report the direct generation of linearly polarized single photons with a deterministic polarization axis in self-assembled quantum dots (QDs, achieved by the use of non-polar InGaN without complex device geometry engineering. Here, we present a comprehensive investigation of the polarization properties of these QDs and their origin with statistically significant experimental data and rigorous k·p modeling. The experimental study of 180 individual QDs allows us to compute an average polarization degree of 0.90, with a standard deviation of only 0.08. When coupled with theoretical insights, we show that these QDs are highly insensitive to size differences, shape anisotropies, and material content variations. Furthermore, 91% of the studied QDs exhibit a polarization axis along the crystal [1–100] axis, with the other 9% polarized orthogonal to this direction. These features give non-polar InGaN QDs unique advantages in polarization control over other materials, such as conventional polar nitride, InAs, or CdSe QDs. Hence, the ability to generate single photons with polarization control makes non-polar InGaN QDs highly attractive for quantum cryptography protocols.

  7. Direct generation of linearly polarized single photons with a deterministic axis in quantum dots

    Science.gov (United States)

    Wang, Tong; Puchtler, Tim J.; Patra, Saroj K.; Zhu, Tongtong; Ali, Muhammad; Badcock, Tom J.; Ding, Tao; Oliver, Rachel A.; Schulz, Stefan; Taylor, Robert A.

    2017-07-01

    We report the direct generation of linearly polarized single photons with a deterministic polarization axis in self-assembled quantum dots (QDs), achieved by the use of non-polar InGaN without complex device geometry engineering. Here, we present a comprehensive investigation of the polarization properties of these QDs and their origin with statistically significant experimental data and rigorous k·p modeling. The experimental study of 180 individual QDs allows us to compute an average polarization degree of 0.90, with a standard deviation of only 0.08. When coupled with theoretical insights, we show that these QDs are highly insensitive to size differences, shape anisotropies, and material content variations. Furthermore, 91% of the studied QDs exhibit a polarization axis along the crystal [1-100] axis, with the other 9% polarized orthogonal to this direction. These features give non-polar InGaN QDs unique advantages in polarization control over other materials, such as conventional polar nitride, InAs, or CdSe QDs. Hence, the ability to generate single photons with polarization control makes non-polar InGaN QDs highly attractive for quantum cryptography protocols.

  8. The Standard Deviation of Launch Vehicle Environments

    Science.gov (United States)

    Yunis, Isam

    2005-01-01

    Statistical analysis is used in the development of the launch vehicle environments of acoustics, vibrations, and shock. The standard deviation of these environments is critical to accurate statistical extrema. However, often very little data exists to define the standard deviation and it is better to use a typical standard deviation than one derived from a few measurements. This paper uses Space Shuttle and expendable launch vehicle flight data to define a typical standard deviation for acoustics and vibrations. The results suggest that 3dB is a conservative and reasonable standard deviation for the source environment and the payload environment.

  9. Parametric study of single-axis acoustic levitation

    Energy Technology Data Exchange (ETDEWEB)

    Xie, W. J.; Wei, B.

    2001-08-06

    Remarkable enhancement of the single-axis acoustic levitation force is achieved by properly curving the surface and enlarging the section of the reflector so as to levitate high density material like tungsten ({rho}{sub s}=18.92g/cm{sup 3}). A two-cylinder model incorporating the boundary element method simulations is presented for systematic study of the relationship between levitation capabilities and geometric parameters. The model proves to be successful in predicting resonant modes and explaining deviation of the levitated samples near the reflector and driver. The dependence of levitation force on resonant mode, reflector section radius R{sub b} and curvature radius R is revealed and summarized, which agrees with the experiment in principle and suggests that a reflector with large R{sub b} and small R (when R{sub b}/{lambda}{>=}0.982) working under mode 1 assures better levitation capabilities. {copyright} 2001 American Institute of Physics.

  10. Parametric study of single-axis acoustic levitation

    International Nuclear Information System (INIS)

    Xie, W. J.; Wei, B.

    2001-01-01

    Remarkable enhancement of the single-axis acoustic levitation force is achieved by properly curving the surface and enlarging the section of the reflector so as to levitate high density material like tungsten (ρ s =18.92g/cm 3 ). A two-cylinder model incorporating the boundary element method simulations is presented for systematic study of the relationship between levitation capabilities and geometric parameters. The model proves to be successful in predicting resonant modes and explaining deviation of the levitated samples near the reflector and driver. The dependence of levitation force on resonant mode, reflector section radius R b and curvature radius R is revealed and summarized, which agrees with the experiment in principle and suggests that a reflector with large R b and small R (when R b /λ≥0.982) working under mode 1 assures better levitation capabilities. Copyright 2001 American Institute of Physics

  11. Unusual congenital pulmonary anomaly with presumed left lung hypoplasia in a young dog.

    Science.gov (United States)

    Lee, C M; Kim, J H; Kang, M H; Eom, K D; Park, H M

    2014-05-01

    A seven-month-old, entire, male miniature schnauzer dog was referred with acute vomiting, inappetence and depression primarily as a result of a gastric foreign body (pine cones). During investigations, thoracic radiographs revealed increased volume of the right lung lobes, deviated cardiomediastinal structures and elevation of the heart from the sternum. Thoracic computed tomography revealed left cranial lung lobe hypoplasia and extension of the right cranial lung parenchyma across the midline to the left hemithorax. Branches of the right pulmonary vessels and bronchi also crossed the midline and extended to the left caudal lung lobe. These findings suggested that the right and left lungs were fused. In humans this finding is consistent with horseshoe lung, which is an uncommon congenital malformation. To the authors' knowledge, this case represents the first report of such a pulmonary anomaly in a dog. © 2014 British Small Animal Veterinary Association.

  12. Deviations from thermal equilibrium in plasmas

    International Nuclear Information System (INIS)

    Burm, K.T.A.L.

    2004-01-01

    A plasma system in local thermal equilibrium can usually be described with only two parameters. To describe deviations from equilibrium two extra parameters are needed. However, it will be shown that deviations from temperature equilibrium and deviations from Saha equilibrium depend on one another. As a result, non-equilibrium plasmas can be described with three parameters. This reduction in parameter space will ease the plasma describing effort enormously

  13. Deviating measurements in radiation protection. Legal assessment of deviations in radiation protection measurements

    International Nuclear Information System (INIS)

    Hoegl, A.

    1996-01-01

    This study investigates how, from a legal point of view, deviations in radiation protection measurements should be treated in comparisons between measured results and limits stipulated by nuclear legislation or goods transport regulations. A case-by-case distinction is proposed which is based on the legal concequences of the respective measurement. Commentaries on nuclear law contain no references to the legal assessment of deviating measurements in radiation protection. The examples quoted in legal commentaries on civil and criminal proceedings of the way in which errors made in measurements for speed control and determinations of the alcohol content in the blood are to be taken into account, and a commentary on ozone legislation, are examined for analogies with radiation protection measurements. Leading cases in the nuclear field are evaluated in the light of the requirements applying in case of deviations in measurements. The final section summarizes the most important findings and conclusions. (orig.) [de

  14. Left ventricular function in chronic aortic regurgitation

    International Nuclear Information System (INIS)

    Iskandrian, A.S.; Hakki, A.H.; Manno, B.; Amenta, A.; Kane, S.A.

    1983-01-01

    Left ventricular performance was determined in 42 patients with moderate or severe aortic regurgitation during upright exercise by measuring left ventricular ejection fraction and volume with radionuclide ventriculography. Classification of the patients according to exercise tolerance showed that patients with normal exercise tolerance (greater than or equal to 7.0 minutes) had a significantly higher ejection fraction at rest (probability [p] . 0.02) and during exercise (p . 0.0002), higher cardiac index at exercise (p . 0.0008) and lower exercise end-systolic volume (p . 0.01) than did patients with limited exercise tolerance. Similar significant differences were noted in younger patients compared with older patients in ejection fraction at rest and exercise (both p . 0.001) and cardiac index at rest (p . 0.03) and exercise (p . 0.0005). The end-diastolic volume decreased during exercise in 60% of the patients. The patients with a decrease in volume were significantly younger and had better exercise tolerance and a larger end-diastolic volume at rest than did patients who showed an increase in volume. The mean corrected left ventricular end-diastolic radius/wall thickness ratio was significantly greater in patients with abnormal than in those with normal exercise reserve (mean +/- standard deviation 476 +/- 146 versus 377 +/- 92 mm Hg, p less than 0.05). Thus, in patients with chronic aortic regurgitation: 1) left ventricular systolic function during exercise was related to age, exercise tolerance and corrected left ventricular end-diastolic radius/wall thickness ratio, and 2) the end-diastolic volume decreased during exercise, especially in younger patients and patients with normal exercise tolerance or a large volume at rest

  15. Effects of Early-Life Adversity on Hippocampal Structures and Associated HPA Axis Functions.

    Science.gov (United States)

    Dahmen, Brigitte; Puetz, Vanessa B; Scharke, Wolfgang; von Polier, Georg G; Herpertz-Dahlmann, Beate; Konrad, Kerstin

    2018-01-01

    Early-life adversity (ELA) is one of the major risk factors for serious mental and physical health risks later in life. ELA has been associated with dysfunctional neurodevelopment, especially in brain structures such as the hippocampus, and with dysfunction of the stress system, including the hypothalamic-pituitary-adrenal (HPA) axis. Children who have experienced ELA are also more likely to suffer from mental health disorders such as depression later in life. The exact interplay of aberrant neurodevelopment and HPA axis dysfunction as risks for psychopathology is not yet clear. We investigated volume differences in the bilateral hippocampus and in stress-sensitive hippocampal subfields, behavior problems, and diurnal cortisol activity in 24 children who had experienced documented ELA (including out-of-home placement) in a circumscribed duration of adversity only in their first 3 years of life in comparison to data on 25 control children raised by their biological parents. Hippocampal volumes and stress-sensitive hippocampal subfields (Cornu ammonis [CA]1, CA3, and the granule-cell layer of the dentate gyrus [GCL-DG]) were significantly smaller in children who had experienced ELA, taking psychiatric diagnoses and dimensional psychopathological symptoms into account. ELA moderated the relationship between left hippocampal volume and cortisol: in the control group, hippocampal volumes were not related to diurnal cortisol, while in ELA children, a positive linear relationship between left hippocampal volume and diurnal cortisol was present. Our findings show that ELA is associated with altered development of the hippocampus, and an altered relationship between hippocampal volume and HPA axis activity in youth in care, even after they have lived in stable and caring foster family environments for years. Altered hippocampal development after ELA could thus be associated with a risk phenotype for the development of psychiatric disorders later in life. © 2017 S. Karger

  16. A Kirschner wire as a transverse-axis guide to improve acetabular cup positioning.

    Science.gov (United States)

    Ishidou, Y; Hirotsu, M; Setoguchi, T; Nagano, S; Kakoi, H; Yokouchi, M; Yamamoto, T; Komiya, S

    2016-04-01

    To compare cup-positioning accuracy in total hip arthroplasty (THA) with or without use of a Kirschner wire as a transverse-axis guide for pelvic alignment. Records of 18 men and 73 women (mean age, 60 years) who underwent primary THA with (n=49) or without (n=42) use of a Kirschner wire as a transverse-axis guide for pelvic alignment were reviewed. A 2.4-mm Kirschner wire as a transversea-xis guide was inserted to the anterior superior iliac spine and was parallel to a line linking the left and right anterior superior iliac spine. The safe zone for cup positioning was defined as 30º to 50° abduction and 10º to 30º anteversion. Of the 5 operative surgeons, 2 were classified as experienced (total surgical volume >300) and 3 as inexperienced (total surgical volume of cup in the safe zone was compared in patients with or without use of the transverse-axis guide and in experienced and inexperienced surgeons. For inexperienced surgeons, the use of the transverse-axis guide significantly improved the proportion of patients with the cup in the safe zone from 90% to 100% for abduction, from 50% to 82.4% for anteversion, and from 40% to 82.4% for both. Patients with the cup inside or outside the safe zone were comparable in terms of body height, weight, BMI, subcutaneous fat thickness, incision length, and acetabular cup size. The use of the transverse-axis guide improved the accuracy of cup positioning by inexperienced surgeons.

  17. Pre-operative Tei Index does not predict left ventricular function immediately after mitral valve repair

    Directory of Open Access Journals (Sweden)

    Chirojit Mukherjee

    2012-01-01

    Full Text Available Echocardiographic assessment of systolic left ventricular (LV function in patients with severe mitral regurgitation (MR undergoing mitral valve (MV repair can be challenging because the measurement of ejection fraction (EF or fractional area change (FAC in pathological states is of questionable value. The aim of our study was to evaluate the usefulness of the pre-operative Tei Index in predicting left ventricular EF or FAC immediately after MV repair. One hundred and thirty patients undergoing MV repair with sinus rhythm pre- and post-operatively were enrolled in this prospective study. Twenty-six patients were excluded due to absence of sinus rhythm post-operatively. Standard transesophageal examination(IE 33,Philips,Netherlands was performed before and after cardiopulmonary bypass according to the guidelines of the ASE/SCA. FAC was determined in the transgastric midpapillary short-axis view. LV EF was measured in the midesophageal four- and two-chamber view. For calculation of the Tei Index, the deep transgastric and the midesophageal four-chamber view were used. Statistical analysis was performed with SPSS 17.0. values are expressed as mean with standard deviation. LV FAC and EF decreased significantly after MV repair (FAC: 56±12% vs. 50±14%, P<0.001; EF: 58±11 vs. 50±12Έ P<0.001. The Tei Index decreased from 0.66±0.23 before MV repair to 0.41±0.19 afterwards (P<0.001. No relationship between pre-operative Tei Index and post-operative FAC or post-operative EF were found (FAC: r=−0.061, P=0.554; EF: r=−0.29, P=0.771. Conclusion: Pre-operative Tei Index is not a good predictor for post-operative FAC and EF in patients undergoing MV repair.

  18. Evaluation of the performance of three tenodesis techniques for the treatment of scapholunate instability: flexion-extension and radial-ulnar deviation.

    Science.gov (United States)

    Alonso-Rasgado, Teresa; Zhang, Qing-Hang; Jimenez-Cruz, David; Bailey, Colin; Pinder, Elizabeth; Mandaleson, Avanthi; Talwalkar, Sumedh

    2017-11-25

    Chronic scapholunate ligament (SL) injuries are difficult to treat and can lead to wrist dysfunction. Whilst several tendon reconstruction techniques have been employed in the management of SL instability, SL gap reappearance after surgery has been reported. Using a finite element model and cadaveric study data, we investigated the performance of the Corella, scapholunate axis (SLAM) and modified Brunelli tenodesis (MBT) techniques. Scapholunate dorsal and volar gap and angle were obtained following virtual surgery undertaken using each of the three reconstruction methods with the wrist positioned in flexion, extension, ulnar deviation and radial deviation, in addition to the ulnar-deviated clenched fist and neutral positions. From the study, it was found that, following simulated scapholunate interosseous ligament rupture, the Corella technique was better able to restore the SL gap and angle close to the intact ligament for all wrist positions investigated, followed by SLAM and MBT. The results suggest that for the tendon reconstruction techniques, the use of multiple junction points between scaphoid and lunate may be of benefit. Graphical abstract The use of multiple junction points between scaphoid and lunate may be of benefit for tendon reconstruction techniques.

  19. Size of Atlas and Axis in Adults with Hyphofosphatemic Rickets – a Comparative Study

    DEFF Research Database (Denmark)

    Gjørup, Hans; Sonnesen, Ane Liselotte; Beck-Nielsen, Signe

    were performed by linear regression analyses adjusting for age and gender. Results The comparison between HR-patients and controls showed significant (p≤0.05) differences in the following outcome variables (mean HR-patients (SD), mean controls (SD)): a) height of the anterior tubercle of atlas 12.85 (1......Title Size of atlas and axis in adults with hyphofosphatemic rickets – a comparative study. Introduction. Deviations from normal anatomy of the cervical column are frequent in some pathologic conditions (cleft-patients, OSA-patients) and in severe malocclusions. Hypophosphatemic rickets (HR...

  20. 9 CFR 318.308 - Deviations in processing.

    Science.gov (United States)

    2010-01-01

    ...) Deviations in processing (or process deviations) must be handled according to: (1)(i) A HACCP plan for canned...) of this section. (c) [Reserved] (d) Procedures for handling process deviations where the HACCP plan... accordance with the following procedures: (a) Emergency stops. (1) When retort jams or breakdowns occur...

  1. Utilization of the bicipital groove axis for confirming alignment of the humerus with transepicondylar and ulnar shaft axes during intramedullary nailing.

    Science.gov (United States)

    Meriç, Gökhan; Zeybek, Gülşah; Kıray, Amaç; Atik, Aziz; Budeyri, Aydın; Koşay, Can

    2015-01-01

    Intramedullary nailing is the preferred surgical treatment of humerus shaft fractures. The purpose of this study was to investigate the relationship between the bicipital groove and specific anatomical landmarks in achieving correct alignment of the humerus during intramedullary nailing, and to describe these anatomical landmarks. Thirty (15 right; 15 left) total upper cadaver extremities were used in this study. After the anatomical landmarks were identified and marked, humeral head axis, transepicondylar axis, ulnar shaft axis, bicipital groove axis, and angular measurements of these were obtained. The mean angle between the bicipital groove axis and transepicondylar axis was 48.17°±12.35º (range: 20.10º to 74.6º). The mean angle between the bicipital groove axis and ulna diaphysis axis was 41.82º±11.56 º (range: 17.91º to 68.27º). The mean angle between the humeral head axis and bicipital groove axis was 20.53°±3.90º (range: 11.85º to 31.81º). The mean retroversion angle between the humeral head axis and transepicondylar axis was 27.52±11.37º (range: 4.26º to 49.36º). The mean angle between the humeral head axis and ulna diaphysis axis was 61.73º±12.08º (range: 33.97º to 86.37º). The mean torsion angle was 62.58º±11.28 º (range: 40.74º to 85.74º). Measurement and utilization of the relationship between the bicipital groove, ulna diaphysis and transepicondylar axes may be used for restoring humeral rotation.

  2. Variations in the origin of inferior phrenic arteries and their relationship to celiac axis variations on CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Aslaner, Ramazan; Pekcevik, Yeliz; Sahin, Hilal [Dept. of Radiology, Tepecik Training and Research Hospital, Izmir (Turkmenistan); Toka, Onur [Dept. of Statistics, Hacettepe University, Ankara (Turkmenistan)

    2017-04-15

    Knowing the origin of the inferior phrenic artery (IPA) is important prior to surgical interventions and interventional radiological procedures related to IPA. We aimed to identify variations in the origin of IPA and to investigate the relationship between the origin of IPA and celiac axis variations using computed tomography angiography (CTA). The CTA images of 1000 patients (737 male and 263 female, the mean age 60, range 18–94 years) were reviewed in an analysis of IPA and celiac axis variations. The origin of IPA was divided into two groups, those originating as a common trunk and those originating independently without a truncus. The relationship between the origin of IPA and celiac axis variation was analyzed using Pearson's chi-square test. Both IPAs originated from a common trunk in 295 (29.5%) patients. From which the majority of the common trunk originated from the aorta. Contrastingly, the inferior phrenic arteries originated from different origins in 705 (70.5%) patients. The majority of the right inferior phrenic artery (RIPA) and the left inferior phrenic artery (LIPA) originated independently from the celiac axis. Variation in the celiac axis were detected in 110 (11%) patients. The origin of IPA was found to be significantly different in the presence of celiac axis variation. The majority of IPA originated from the aorta in patients with a common IPA trunk, while the majority of RIPA and LIPA originating from the celiac axis in patients without a common IPA trunk. Thus, the origin of IPA may widely differ in the presence of celiac axis variation.

  3. Variations in the origin of inferior phrenic arteries and their relationship to celiac axis variations on CT angiography

    International Nuclear Information System (INIS)

    Aslaner, Ramazan; Pekcevik, Yeliz; Sahin, Hilal; Toka, Onur

    2017-01-01

    Knowing the origin of the inferior phrenic artery (IPA) is important prior to surgical interventions and interventional radiological procedures related to IPA. We aimed to identify variations in the origin of IPA and to investigate the relationship between the origin of IPA and celiac axis variations using computed tomography angiography (CTA). The CTA images of 1000 patients (737 male and 263 female, the mean age 60, range 18–94 years) were reviewed in an analysis of IPA and celiac axis variations. The origin of IPA was divided into two groups, those originating as a common trunk and those originating independently without a truncus. The relationship between the origin of IPA and celiac axis variation was analyzed using Pearson's chi-square test. Both IPAs originated from a common trunk in 295 (29.5%) patients. From which the majority of the common trunk originated from the aorta. Contrastingly, the inferior phrenic arteries originated from different origins in 705 (70.5%) patients. The majority of the right inferior phrenic artery (RIPA) and the left inferior phrenic artery (LIPA) originated independently from the celiac axis. Variation in the celiac axis were detected in 110 (11%) patients. The origin of IPA was found to be significantly different in the presence of celiac axis variation. The majority of IPA originated from the aorta in patients with a common IPA trunk, while the majority of RIPA and LIPA originating from the celiac axis in patients without a common IPA trunk. Thus, the origin of IPA may widely differ in the presence of celiac axis variation

  4. Variations in the Origin of Inferior Phrenic Arteries and Their Relationship to Celiac Axis Variations on CT Angiography.

    Science.gov (United States)

    Aslaner, Ramazan; Pekcevik, Yeliz; Sahin, Hilal; Toka, Onur

    2017-01-01

    Knowing the origin of the inferior phrenic artery (IPA) is important prior to surgical interventions and interventional radiological procedures related to IPA. We aimed to identify variations in the origin of IPA and to investigate the relationship between the origin of IPA and celiac axis variations using computed tomography angiography (CTA). The CTA images of 1000 patients (737 male and 263 female, the mean age 60, range 18-94 years) were reviewed in an analysis of IPA and celiac axis variations. The origin of IPA was divided into two groups, those originating as a common trunk and those originating independently without a truncus. The relationship between the origin of IPA and celiac axis variation was analyzed using Pearson's chi-square test. Both IPAs originated from a common trunk in 295 (29.5%) patients. From which the majority of the common trunk originated from the aorta. Contrastingly, the inferior phrenic arteries originated from different origins in 705 (70.5%) patients. The majority of the right inferior phrenic artery (RIPA) and the left inferior phrenic artery (LIPA) originated independently from the celiac axis. Variation in the celiac axis were detected in 110 (11%) patients. The origin of IPA was found to be significantly different in the presence of celiac axis variation. The majority of IPA originated from the aorta in patients with a common IPA trunk, while the majority of RIPA and LIPA originating from the celiac axis in patients without a common IPA trunk. Thus, the origin of IPA may widely differ in the presence of celiac axis variation.

  5. Introducing the Mean Absolute Deviation "Effect" Size

    Science.gov (United States)

    Gorard, Stephen

    2015-01-01

    This paper revisits the use of effect sizes in the analysis of experimental and similar results, and reminds readers of the relative advantages of the mean absolute deviation as a measure of variation, as opposed to the more complex standard deviation. The mean absolute deviation is easier to use and understand, and more tolerant of extreme…

  6. Differences among doses for neuro-axis radiotherapy planning in the gonadal region

    International Nuclear Information System (INIS)

    Lima, F.F de; Vilela, E.C.; Oliveira, F.L.; Filho, J.A.

    2015-01-01

    Radiotherapy can disrupt the functioning of the hypothalamic-pituitary axis, directly causing ovarian deficiencies, such as the decrease in fertility or damage that renders the uterus incapable of accommodating the growth of a fetus. However, these issues have become increasingly important to a growing number of pediatric and adolescent cancer survivors. The whole-body, cranial-spinal axis, as well as abdomen and pelvic region irradiations may expose the ovaries to radiation and may cause premature ovarian failure, whereas doses above 35 Gy cranial can affect the hypothalamic-pituitary functions. This study performed a comparison of four doses of radiotherapy planning techniques for the neural axis. For this analysis, technical simulations were performed for the treatment of medulloblastoma in four different planning, applied in a RANDO anthropomorphic phantom and dosimeters (TLD-100). The radiation fields in the 1”st and 2”nd planning were 40 x 5 cm”2 and 17 x 5 cm”2 with 4.0 cm depth, in which doses were 0.03 and 0.05 Gy / day and 0.11 and 0.09 Gy / days, on the right and left sides, respectively. The 3”rd and 4”th measured planning 32 x 7 cm”2 and 18 x 7 cm”2, with a 2 cm gap and a 4.0 and 5.0 cm depth, in which doses were 1.08 and 0.2 Gy/day and 1.14 and 0.14 Gy/day, on the left and right sides, respectively. It could be observed that the doses in the ovaries in the 3”rd and 4”th schedules proved to be larger than the doses in the 1 s t and 2 n d planning. This is caused by the spinal field width and the depth of the second spinal field, which is 1.0 cm more than the field of the 1”st and 2”nd planning. These differences should be observed in image planning, as incorrect measures can cause damage in the treatment finish. (authors)

  7. Magnetic resonance tissue phase mapping demonstrates altered left ventricular diastolic function in children with chronic kidney disease

    Energy Technology Data Exchange (ETDEWEB)

    Gimpel, Charlotte; Pohl, Martin [Medical Center - University of Freiburg, Department of General Pediatrics, Adolescent Medicine and Neonatology, Center for Pediatrics, Freiburg (Germany); Jung, Bernd A. [Inselspital Bern, Institute of Diagnostic, Interventional and Pediatric Radiology, Bern (Switzerland); Jung, Sabine [Medical Center - University of Freiburg, Department of Nuclear Medicine, Freiburg (Germany); Brado, Johannes; Odening, Katja E. [University Heart Center Freiburg, Department of Cardiology and Angiology I, Freiburg (Germany); Schwendinger, Daniel [University Children' s Hospital Zurich, Zurich (Switzerland); Burkhardt, Barbara [University Children' s Hospital Zurich, Pediatric Heart Center, Zurich (Switzerland); Geiger, Julia [University Children' s Hospital Zurich, Department of Radiology, Zurich (Switzerland); Northwestern University, Department of Radiology, Chicago, IL (United States); Arnold, Raoul [University Hospital Heidelberg, Department of Pediatric and Congenital Cardiology, Heidelberg (Germany)

    2017-02-15

    Echocardiographic examinations have revealed functional cardiac abnormalities in children with chronic kidney disease. To assess the feasibility of MRI tissue phase mapping in children and to assess regional left ventricular wall movements in children with chronic kidney disease. Twenty pediatric patients with chronic kidney disease (before or after renal transplantation) and 12 healthy controls underwent tissue phase mapping (TPM) to quantify regional left ventricular function through myocardial long (Vz) and short-axis (Vr) velocities at all 3 levels of the left ventricle. Patients and controls (age: 8 years - 20 years) were matched for age, height, weight, gender and heart rate. Patients had higher systolic blood pressure. No patient had left ventricular hypertrophy on MRI or diastolic dysfunction on echocardiography. Fifteen patients underwent tissue Doppler echocardiography, with normal z-scores for mitral early diastolic (V{sub E}), late diastolic (V{sub A}) and peak systolic (V{sub S}) velocities. Throughout all left ventricular levels, peak diastolic Vz and Vr (cm/s) were reduced in patients: Vz{sub base} -10.6 ± 1.9 vs. -13.4 ± 2.0 (P < 0.0003), Vz{sub mid} -7.8 ± 1.6 vs. -11 ± 1.5 (P < 0.0001), Vz{sub apex} -3.8 ± 1.6 vs. -5.3 ± 1.6 (P = 0.01), Vr{sub base} -4.2 ± 0.8 vs. -4.9 ± 0.7 (P = 0.01), Vr{sub mid} -4.7 ± 0.7 vs. -5.4 ± 0.7 (P = 0.01), Vr{sub apex} -4.7 ± 1.4 vs. -5.6 ± 1.1 (P = 0.05). Tissue phase mapping is feasible in children and adolescents. Children with chronic kidney disease show significantly reduced peak diastolic long- and short-axis left ventricular wall velocities, reflecting impaired early diastolic filling. Thus, tissue phase mapping detects chronic kidney disease-related functional myocardial changes before overt left ventricular hypertrophy or echocardiographic diastolic dysfunction occurs. (orig.)

  8. Fidelity deviation in quantum teleportation

    Science.gov (United States)

    Bang, Jeongho; Ryu, Junghee; Kaszlikowski, Dagomir

    2018-04-01

    We analyze the performance of quantum teleportation in terms of average fidelity and fidelity deviation. The average fidelity is defined as the average value of the fidelities over all possible input states and the fidelity deviation is their standard deviation, which is referred to as a concept of fluctuation or universality. In the analysis, we find the condition to optimize both measures under a noisy quantum channel—we here consider the so-called Werner channel. To characterize our results, we introduce a 2D space defined by the aforementioned measures, in which the performance of the teleportation is represented as a point with the channel noise parameter. Through further analysis, we specify some regions drawn for different channel conditions, establishing the connection to the dissimilar contributions of the entanglement to the teleportation and the Bell inequality violation.

  9. Right Ventricular Outflow Tract Tachycardia with Structural Abnormalities of the Right Ventricle and Left Ventricular Diverticulum

    Directory of Open Access Journals (Sweden)

    Bortolo Martini

    2015-01-01

    Full Text Available A 43-year-old woman presented to the emergency room with a sustained ventricular tachycardia (VT. ECG showed a QRS in left bundle branch block morphology with inferior axis. Echocardiography, ventricular angiography, and cardiac magnetic resonance imaging (CMRI revealed a normal right ventricle and a left ventricular diverticulum. Electrophysiology studies with epicardial voltage mapping identified a large fibrotic area in the inferolateral layer of the right ventricular wall and a small area of fibrotic tissue at the anterior right ventricular outflow tract. VT ablation was successfully performed with combined epicardial and endocardial approaches.

  10. Large deviations for noninteracting infinite-particle systems

    International Nuclear Information System (INIS)

    Donsker, M.D.; Varadhan, S.R.S.

    1987-01-01

    A large deviation property is established for noninteracting infinite particle systems. Previous large deviation results obtained by the authors involved a single I-function because the cases treated always involved a unique invariant measure for the process. In the context of this paper there is an infinite family of invariant measures and a corresponding infinite family of I-functions governing the large deviations

  11. Development of 6-axis portable manipulator which traces over 3-dimensional curved surface for ultrasonic inspection

    International Nuclear Information System (INIS)

    Hayashi, Tetsuji; Tsuzuki, Satoshi; Tsunewaki, Hiroshi.

    1993-01-01

    A 6-axis portable manipulator, weighing 120 N (12.3 kg) which traces over a 3-dimensional curved surface for ultrasonic testing has been developed. The manipulator body is made of carbon-fiber-reinforced plastic and magnesium alloy. A feature of the system is that deviation of the manipulator from its nominal path caused by arm bending due to its own weight can be corrected. The deviation is calculated by premeasuring spring coefficients and hysteresis characteristics of the arm structure. In a mock-up calibration performance test the accuracy was shown to be as high as that of a human inspector. The manipulator can be installed within 3 minutes by a single person. Joint angles are calculated with a direct memory access (DMA) handler using a poling method. Signals are transmitted to servo-controllers through an optical fiber of 2.5 Mbps. (author)

  12. Left Ventricular Myocardial Deformation Parameters Are Affected by Coronary Slow Flow Phenomenon: A Study of Speckle Tracking Echocardiography.

    Science.gov (United States)

    Gulel, Okan; Akcay, Murat; Soylu, Korhan; Aksan, Gokhan; Yuksel, Serkan; Zengin, Halit; Meric, Murat; Sahin, Mahmut

    2016-05-01

    The coronary slow flow phenomenon (CSFP) is defined as a delayed distal vessel contrast opacification in the absence of obstructive epicardial coronary artery disease during coronary angiography. There is conflicting data in medical literature regarding the effects of CSFP on the left ventricular functions assessed by conventional echocardiography or tissue Doppler imaging. Therefore, we aimed to evaluate whether there is any abnormality in the myocardial deformation parameters (strain, strain rate (SR), rotation, twist) of the left ventricle obtained by speckle tracking echocardiography (STE) in patients with CSFP. Twenty patients with CSFP were included prospectively in the study. Another 20 patients with similar demographics and cardiovascular risk factors as well as normal coronary angiography were used as the control group. Two-dimensional echocardiographic images of the left ventricle from the apical long-axis, two-chamber, four-chamber, and parasternal short-axis views were used for STE analysis. The analysis of left ventricular circumferential deformation parameters showed that the averaged peak systolic strain, systolic SR, and early diastolic SR values were significantly lower in patients with CSFP (P = 0.009, P = 0.02, and P = 0.02, respectively). Among the left ventricular rotation and twist values, apical rotation was significantly lower in patients with CSFP (P = 0.02). Further, the mean thrombolysis in myocardial infarction frame count value was found to be negatively correlated with the averaged peak circumferential early diastolic SR (r = -0.35, P = 0.03). It was positively correlated with the averaged peak circumferential systolic strain (r = 0.47, P = 0.003) and circumferential systolic SR (r = 0.46, P = 0.005). Coronary slow flow phenomenon leads to significant alterations in the myocardial deformation parameters of the left ventricle as assessed by STE. Specifically, circumferential deformation parameters are affected in CSFP patients. © 2015

  13. 48 CFR 1401.403 - Individual deviations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Individual deviations. 1401.403 Section 1401.403 Federal Acquisition Regulations System DEPARTMENT OF THE INTERIOR GENERAL DEPARTMENT OF THE INTERIOR ACQUISITION REGULATION SYSTEM Deviations from the FAR and DIAR 1401.403 Individual...

  14. TERMINOLOGY MANAGEMENT FRAMEWORK DEVIATIONS IN PROJECTS

    Directory of Open Access Journals (Sweden)

    Олена Борисівна ДАНЧЕНКО

    2015-05-01

    Full Text Available The article reviews new approaches to managing projects deviations (risks, changes, problems. By offering integrated control these parameters of the project and by analogy with medical terminological systems building a new system for managing terminological variations in the projects. With an improved method of triads system definitions are analyzed medical terms that make up terminological basis. Using the method of analogy proposed new definitions for managing deviations in projects. By using triad integrity built a new system triad in project management, which will subsequently also analogous to develop a new methodology of deviations in projects.

  15. Gut Microbiota-brain Axis

    Institute of Scientific and Technical Information of China (English)

    Hong-Xing Wang; Yu-Ping Wang

    2016-01-01

    Objective:To systematically review the updated information about the gut microbiota-brain axis.Data Sources:All articles about gut microbiota-brain axis published up to July 18,2016,were identified through a literature search on PubMed,ScienceDirect,and Web of Science,with the keywords of"gut microbiota","gut-brain axis",and "neuroscience".Study Selection:All relevant articles on gut microbiota and gut-brain axis were included and carefully reviewed,with no limitation of study design.Results:It is well-recognized that gut microbiota affects the brain's physiological,behavioral,and cognitive functions although its precise mechanism has not yet been fully understood.Gut microbiota-brain axis may include gut microbiota and their metabolic products,enteric nervous system,sympathetic and parasympathetic branches within the autonomic nervous system,neural-immune system,neuroendocrine system,and central nervous system.Moreover,there may be five communication routes between gut microbiota and brain,including the gut-brain's neural network,neuroendocrine-hypothalamic-pituitary-adrenal axis,gut immune system,some neurotransmitters and neural regulators synthesized by gut bacteria,and barrier paths including intestinal mucosal barrier and blood-brain barrier.The microbiome is used to define the composition and functional characteristics of gut microbiota,and metagenomics is an appropriate technique to characterize gut microbiota.Conclusions:Gut microbiota-brain axis refers to a bidirectional information network between the gut microbiota and the brain,which may provide a new way to protect the brain in the near future.

  16. 41 CFR 115-1.110 - Deviations.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Deviations. 115-1.110 Section 115-1.110 Public Contracts and Property Management Federal Property Management Regulations System (Continued) ENVIRONMENTAL PROTECTION AGENCY 1-INTRODUCTION 1.1-Regulation System § 115-1.110 Deviations...

  17. Minimally invasive radical pancreatectomy for left-sided pancreatic cancer: Current status and future perspectives

    Science.gov (United States)

    Kang, Chang Moo; Lee, Sung Hwan; Lee, Woo Jung

    2014-01-01

    Minimally invasive distal pancreatectomy with splenectomy has been regarded as a safe and effective treatment for benign and borderline malignant pancreatic lesions. However, its application for left-sided pancreatic cancer is still being debated. The clinical evidence for radical antegrade modular pancreatosplenectomy (RAMPS)-based minimally invasive approaches for left-sided pancreatic cancer was reviewed. Potential indications and surgical concepts for minimally invasive RAMPS were suggested. Despite the limited clinical evidence for minimally invasive distal pancreatectomy in left-sided pancreatic cancer, the currently available clinical evidence supports the use of laparoscopic distal pancreatectomy under oncologic principles in well-selected left sided pancreatic cancers. A pancreas-confined tumor with an intact fascia layer between the pancreas and left adrenal gland/kidney positioned more than 1 or 2 cm away from the celiac axis is thought to constitute a good condition for the use of margin-negative minimally invasive RAMPS. The use of minimally invasive (laparoscopic or robotic) anterior RAMPS is feasible and safe for margin-negative resection in well-selected left-sided pancreatic cancer. The oncologic feasibility of the procedure remains to be determined; however, the currently available interim results indicate that even oncologic outcomes will not be inferior to those of open radical distal pancreatosplenectomy. PMID:24605031

  18. Quantitative cine-left ventriculography - Superiority of 45 .deg. RAO view to straight AB view -

    International Nuclear Information System (INIS)

    Lim, Tae Hwan; Han, Man Chung

    1981-01-01

    The volumetry by cineangiocardiography is known to have the most diagnostic and prognostic value in the evaluation of various valvular heart diseases and ischemic heart diseases. Although many authors favor the area-length method for the volumetry of left ventricle, 45 .deg. RAO projection seems to be more simple, inexpensive and accurate technique, considering the positional relationship of cardiac valves and obliquity of the long axis of left ventricle within the chest cage. Authors present the anatomical, geometrical and radiological basis for the superiority of 45 .deg. RAO protection by analyzing 20 normal heart specimen and 115 cineangiocardiograms of valvular heart diseases, and the results as follows: 1. Blood flow and motility of the mitral and aortic valves can be more clearly demonstrated by 45 .deg. RAO projection than by AP view. 2. The long diameter of left ventricular silhouette made 45 .deg. RAO projection reflects 90% or more of real diameter. 3. In RAO 45 .deg. position, patient's left nipple is optimal and convenient level for the ruler offering accurate magnification coefficient of left ventricle. 4. Ejection fraction after the extrasystole is exaggerated regardless of the left ventricular function, so it is desirable to exclude the 2 or 3 beats after extrasystole

  19. The coiled-coil domain containing protein CCDC40 is essential for motile cilia function and left-right axis formation

    DEFF Research Database (Denmark)

    Becker-Heck, Anita; Zohn, Irene E; Okabe, Noriko

    2011-01-01

    Primary ciliary dyskinesia (PCD) is a genetically heterogeneous autosomal recessive disorder characterized by recurrent infections of the respiratory tract associated with the abnormal function of motile cilia. Approximately half of individuals with PCD also have alterations in the left-right...... organization of their internal organ positioning, including situs inversus and situs ambiguous (Kartagener's syndrome). Here, we identify an uncharacterized coiled-coil domain containing a protein, CCDC40, essential for correct left-right patterning in mouse, zebrafish and human. In mouse and zebrafish, Ccdc40...

  20. 41 CFR 105-1.110 - Deviation.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Deviation. 105-1.110 Section 105-1.110 Public Contracts and Property Management Federal Property Management Regulations System (Continued) GENERAL SERVICES ADMINISTRATION 1-INTRODUCTION 1.1-Regulations System § 105-1.110 Deviation. (a...

  1. 41 CFR 101-1.110 - Deviation.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 2 2010-07-01 2010-07-01 true Deviation. 101-1.110 Section 101-1.110 Public Contracts and Property Management Federal Property Management Regulations System FEDERAL PROPERTY MANAGEMENT REGULATIONS GENERAL 1-INTRODUCTION 1.1-Regulation System § 101-1.110 Deviation...

  2. [Application of tibial mechanical axis locator in tibial extra-articular deformity in total knee arthroplasty].

    Science.gov (United States)

    Li, Guoliang; Han, Guangpu; Zhang, Jinxiu; Ma, Shiqiang; Guo, Donghui; Yuan, Fulu; Qi, Bingbing; Shen, Runbin

    2013-07-01

    To explore the application value of self-made tibial mechanical axis locator in tibial extra-articular deformity in total knee arthroplasty (TKA) for improving the lower extremity force line. Between January and August 2012, 13 cases (21 knees) of osteoarthritis with tibial extra-articular deformity were treated, including 5 males (8 knees) and 8 females (13 knees) with an average age of 66.5 years (range, 58-78 years). The disease duration was 2-5 years (mean, 3.5 years). The knee society score (KSS) was 45.5 +/- 15.5. Extra-articular deformities included 1 case of knee valgus (2 knees) and 12 cases of knee varus (19 knees). Preoperative full-length X-ray films of lower extremities showed 10-21 degrees valgus or varus deformity of tibial extra joint. Self-made tibial mechanical axis locator was used to determine and mark coronal tibial mechanical axis under X-ray before TKA, and then osteotomy was performed with extramedullary positioning device according to the mechanical axis marker.' All incisions healed by first intention, without related complications of infection and joint instability. All patients were followed up 5-12 months (mean, 8.3 months). The X-ray examination showed case of 2.9 degrees knee deviation angle at 3 days after operation, and the accurate rate was 95.2%. No loosening or instability of prosthesis occurred during follow-up. KSS score was 85.5 +/- 15.0 at last follow-up, showing significant difference when compared with preoperative score (t=12.82, P=0.00). The seft-made tibial mechanical axis locator can improve the accurate rate of the lower extremity force line in TKA for tibia extra-articular deformity.

  3. Mechanical impedance of the sitting human body in single-axis compared to multi-axis whole-body vibration exposure.

    Science.gov (United States)

    Holmlund, P; Lundström, R

    2001-01-01

    The study was aimed to investigate the mechanical impedance of the sitting human body and to compare data obtained in laboratory single-axis investigations with multi-axis data from in vehicle measurements. The experiments were performed in a laboratory for single-axis measurements. The multi-axis exposure was generated with an eight-seat minibus where the rear seats had been replaced with a rigid one. The subjects in the multi-axis experiment all participated in the single-axis experiments. There are quite a few investigations in the literature describing the human response to single-axis exposure. The response from the human body can be expected to be affected by multi-axis input in a different way than from a single-axis exposure. The present knowledge of the effect of multiple axis exposure is very limited. The measurements were performed using a specially designed force and accelerometer plate. This plate was placed between the subject and the hard seat. Outcome shows a clear difference between mechanical impedance for multi-axis exposure compared to single-axis. This is especially clear in the x-direction where the difference is very large. The conclusion is that it seems unlikely that single-axis mechanical impedance data can be directly transferred to a multi-axis environment. This is due to the force cross-talk between different directions.

  4. Environmental stressors and epigenetic control of the hypothalamic-pituitary-adrenal-axis (HPA-axis)

    OpenAIRE

    Lee, Richard; Sawa, Akira

    2014-01-01

    In this review, we provide a brief summary of several key studies that broaden our understanding of stress and its epigenetic control of the hypothalamic-pituitary-adrenal axis (HPA)-axis function and behavior. Clinical and animal studies suggest a link among exposure to stress, dysregulation of the HPA-axis, and susceptibility to neuropsychiatric illnesses. Recent studies have supported the notion that exposure to glucocorticoids and stress in various forms, duration, and intensity during di...

  5. Comparing Standard Deviation Effects across Contexts

    Science.gov (United States)

    Ost, Ben; Gangopadhyaya, Anuj; Schiman, Jeffrey C.

    2017-01-01

    Studies using tests scores as the dependent variable often report point estimates in student standard deviation units. We note that a standard deviation is not a standard unit of measurement since the distribution of test scores can vary across contexts. As such, researchers should be cautious when interpreting differences in the numerical size of…

  6. Transport Coefficients from Large Deviation Functions

    Directory of Open Access Journals (Sweden)

    Chloe Ya Gao

    2017-10-01

    Full Text Available We describe a method for computing transport coefficients from the direct evaluation of large deviation functions. This method is general, relying on only equilibrium fluctuations, and is statistically efficient, employing trajectory based importance sampling. Equilibrium fluctuations of molecular currents are characterized by their large deviation functions, which are scaled cumulant generating functions analogous to the free energies. A diffusion Monte Carlo algorithm is used to evaluate the large deviation functions, from which arbitrary transport coefficients are derivable. We find significant statistical improvement over traditional Green–Kubo based calculations. The systematic and statistical errors of this method are analyzed in the context of specific transport coefficient calculations, including the shear viscosity, interfacial friction coefficient, and thermal conductivity.

  7. Transport Coefficients from Large Deviation Functions

    Science.gov (United States)

    Gao, Chloe; Limmer, David

    2017-10-01

    We describe a method for computing transport coefficients from the direct evaluation of large deviation function. This method is general, relying on only equilibrium fluctuations, and is statistically efficient, employing trajectory based importance sampling. Equilibrium fluctuations of molecular currents are characterized by their large deviation functions, which is a scaled cumulant generating function analogous to the free energy. A diffusion Monte Carlo algorithm is used to evaluate the large deviation functions, from which arbitrary transport coefficients are derivable. We find significant statistical improvement over traditional Green-Kubo based calculations. The systematic and statistical errors of this method are analyzed in the context of specific transport coefficient calculations, including the shear viscosity, interfacial friction coefficient, and thermal conductivity.

  8. Electrocardiographic features of patients with earthquake related posttraumatic stress disorder

    Science.gov (United States)

    İlhan, Erkan; Kaplan, Abdullah; Güvenç, Tolga Sinan; Biteker, Murat; Karabulut, Evindar; Işıklı, Serhan

    2013-01-01

    AIM: To analyze electrocardiographic features of patients diagnosed with posttraumatic stress disorder (PTSD) after the Van-Erciş earthquake, with a shock measuring 7.2 on the Richter scale that took place in Turkey in October 2011. METHODS: Surface electrocardiograms of 12 patients with PTSD admitted to Van Erciş State Hospital (Van, Turkey) from February 2012 to May 2012 were examined. Psychiatric interviews of the sex and age matched control subjects, who had experienced the earthquake, confirmed the absence of any known diagnosable psychiatric conditions in the control group. RESULTS: A wide range of electrocardiogram (ECG) parameters, such as P-wave dispersion, QT dispersion, QT interval, Tpeak to Tend interval, intrinsicoid deflection durations and other traditional parameters were similar in both groups. There was no one with an abnormal P wave axis, short or long PR interval, long or short QT interval, negative T wave in lateral leads, abnormal T wave axis, abnormal left or right intrinsicoid deflection duration, low voltage, left bundle branch block, right bundle branch block, left posterior hemiblock, left or right axis deviation, left ventricular hypertrophy, right or left atrial enlargement and pathological q(Q) wave in either group. CONCLUSION: The study showed no direct effect of earthquake related PTSD on surface ECG in young patients. So, we propose that PTSD has no direct effect on surface ECG but may cause electrocardiographic changes indirectly by triggering atherosclerosis and/or contributing to the ongoing atherosclerotic process. PMID:23538549

  9. 41 CFR 109-1.110-50 - Deviation procedures.

    Science.gov (United States)

    2010-07-01

    ... best interest of the Government; (3) If applicable, the name of the contractor and identification of... background information which will contribute to a full understanding of the desired deviation. (b)(1... authorized to grant deviations to the DOE-PMR. (d) Requests for deviations from the FPMR will be coordinated...

  10. Experimental Study on the Axis Line Deflection of Ti6A14V Titanium Alloy in Gun-Drilling Process

    Science.gov (United States)

    Li, Liang; Xue, Hu; Wu, Peng

    2018-01-01

    Titanium alloy is widely used in aerospace industry, but it is also a typical difficult-to-cut material. During Deep hole drilling of the shaft parts of a certain large aircraft, there are problems of bad surface roughness, chip control and axis deviation, so experiments on gun-drilling of Ti6A14V titanium alloy were carried out to measure the axis line deflection, diameter error and surface integrity, and the reasons of these errors were analyzed. Then, the optimized process parameter was obtained during gun-drilling of Ti6A14V titanium alloy with deep hole diameter of 17mm. Finally, we finished the deep hole drilling of 860mm while the comprehensive error is smaller than 0.2mm and the surface roughness is less than 1.6μm.

  11. Assessment of left ventricular performance by ECG-gated SPECT. Comparison with magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Tadamura, Eiji; Inubushi, Masayuki; Kubo, Shigeto; Matsumoto, Keiichi; Yokoyama, Hiroshi; Fujita, Toru; Konishi, Junji [Kyoto Univ. (Japan). Faculty of Medicine

    1999-10-01

    In the measurement of a left ventricular volume, MIBI-QGS was compared with MRI. Because it became clear by the experiment using phantom that a volume calculated with QGS was smaller than the actual volume, data of clinical study were corrected. Subjects were 20 patients with coronary artery disease. Fourteen patients had anamnesis of myocardial infarct. ECG-gated SPECT was performed one hour after intravenous injection of MIBI (600 MBq) in rest. End diastolic volume (EDV), end systolic volume (ESV) and ejection fraction (EF) were calculated using QGS. Cine-MR image was obtained by using MR system of 1.5 Tesla within 1 week after SPECT. A condition was as follows; segmented k-space gradient echo with view sharing, TR=11 ms, TE=1.4 ms, flip angle 20 degree, field of view 32 cm, matrix 256 x 196, 8 lines per segment. LVEF, ESV and EF were analysed by Bland-Altman method, and the difference between MIBI-gated-SPECT and MRI was no problem. Horizontal dislocation image and vertical major axis dislocation image were provided. Minor axis crossing images of 10-12 slice were also filmed in order to cover all left ventricles. As a result, availability of MIBI-QGS became clear. Some factors which produces the measurement error are examined. (K.H.)

  12. Planar cell polarity enables posterior localization of nodal cilia and left-right axis determination during mouse and Xenopus embryogenesis.

    Directory of Open Access Journals (Sweden)

    Dragana Antic

    2010-02-01

    Full Text Available Left-right asymmetry in vertebrates is initiated in an early embryonic structure called the ventral node in human and mouse, and the gastrocoel roof plate (GRP in the frog. Within these structures, each epithelial cell bears a single motile cilium, and the concerted beating of these cilia produces a leftward fluid flow that is required to initiate left-right asymmetric gene expression. The leftward fluid flow is thought to result from the posterior tilt of the cilia, which protrude from near the posterior portion of each cell's apical surface. The cells, therefore, display a morphological planar polarization. Planar cell polarity (PCP is manifested as the coordinated, polarized orientation of cells within epithelial sheets, or as directional cell migration and intercalation during convergent extension. A set of evolutionarily conserved proteins regulates PCP. Here, we provide evidence that vertebrate PCP proteins regulate planar polarity in the mouse ventral node and in the Xenopus gastrocoel roof plate. Asymmetric anterior localization of VANGL1 and PRICKLE2 (PK2 in mouse ventral node cells indicates that these cells are planar polarized by a conserved molecular mechanism. A weakly penetrant Vangl1 mutant phenotype suggests that compromised Vangl1 function may be associated with left-right laterality defects. Stronger functional evidence comes from the Xenopus GRP, where we show that perturbation of VANGL2 protein function disrupts the posterior localization of motile cilia that is required for leftward fluid flow, and causes aberrant expression of the left side-specific gene Nodal. The observation of anterior-posterior PCP in the mouse and in Xenopus embryonic organizers reflects a strong evolutionary conservation of this mechanism that is important for body plan determination.

  13. Tuning the DARHT Axis-II linear induction accelerator focusing

    Energy Technology Data Exchange (ETDEWEB)

    Ekdahl, Carl A. [Los Alamos National Laboratory

    2012-04-24

    accelerator cell to replace a failed solenoid in March of 2012. We took advantage of this opportunity to improve the design of the focusing tune with better models of the remaining partially failed solenoids, better estimates of beam initial conditions, and better values for pulsed-power voltages. As with all previous tunes for Axis-II, this one incorporates measures to mitigate beam-breakup (BBU) instability, image displacement instability (IDI), corkscrew (sweep), and emittance growth. Section II covers the general approach to of design of focusing solenoid tunes for the DARHT Axis-2 LIA. Section III explains the specific requirements and simulations needed to design the tune for the injector, which includes the thermionic electron source, diode, and six induction cells. Section IV explains the requirements and simulations for tuning the main accelerator, which consists of 68 induction cells. Finally, Section V explores sensitivity of the tune to deviations of parameters from nominal, random variations, and uncertainties in values. Four appendices list solenoid settings for this new tune, discuss comparisons of different simulation codes, show halo formation in mismatched beams, and present a brief discussion of the beam envelope equation, which is the heart of the method used to design LIA solenoid tunes.

  14. Klf8 regulates left-right asymmetric patterning through modulation of Kupffer's vesicle morphogenesis and spaw expression.

    Science.gov (United States)

    Lin, Che-Yi; Tsai, Ming-Yuan; Liu, Yu-Hsiu; Lu, Yu-Fen; Chen, Yi-Chung; Lai, Yun-Ren; Liao, Hsin-Chi; Lien, Huang-Wei; Yang, Chung-Hsiang; Huang, Chang-Jen; Hwang, Sheng-Ping L

    2017-07-17

    Although vertebrates are bilaterally symmetric organisms, their internal organs are distributed asymmetrically along a left-right axis. Disruption of left-right axis asymmetric patterning often occurs in human genetic disorders. In zebrafish embryos, Kupffer's vesicle, like the mouse node, breaks symmetry by inducing asymmetric expression of the Nodal-related gene, spaw, in the left lateral plate mesoderm (LPM). Spaw then stimulates transcription of itself and downstream genes, including lft1, lft2, and pitx2, specifically in the left side of the diencephalon, heart and LPM. This developmental step is essential to establish subsequent asymmetric organ positioning. In this study, we evaluated the role of krüppel-like factor 8 (klf8) in regulating left-right asymmetric patterning in zebrafish embryos. Zebrafish klf8 expression was disrupted by both morpholino antisense oligomer-mediated knockdown and a CRISPR-Cas9 system. Whole-mount in situ hybridization was conducted to evaluate gene expression patterns of Nodal signalling components and the positions of heart and visceral organs. Dorsal forerunner cell number was evaluated in Tg(sox17:gfp) embryos and the length and number of cilia in Kupffer's vesicle were analyzed by immunocytochemistry using an acetylated tubulin antibody. Heart jogging, looping and visceral organ positioning were all defective in zebrafish klf8 morphants. At the 18-22 s stages, klf8 morphants showed reduced expression of genes encoding Nodal signalling components (spaw, lft1, lft2, and pitx2) in the left LPM, diencephalon, and heart. Co-injection of klf8 mRNA with klf8 morpholino partially rescued spaw expression. Furthermore, klf8 but not klf8△zf overexpressing embryos showed dysregulated bilateral expression of Nodal signalling components at late somite stages. At the 10s stage, klf8 morphants exhibited reductions in length and number of cilia in Kupffer's vesicle, while at 75% epiboly, fewer dorsal forerunner cells were observed

  15. The large deviation approach to statistical mechanics

    International Nuclear Information System (INIS)

    Touchette, Hugo

    2009-01-01

    The theory of large deviations is concerned with the exponential decay of probabilities of large fluctuations in random systems. These probabilities are important in many fields of study, including statistics, finance, and engineering, as they often yield valuable information about the large fluctuations of a random system around its most probable state or trajectory. In the context of equilibrium statistical mechanics, the theory of large deviations provides exponential-order estimates of probabilities that refine and generalize Einstein's theory of fluctuations. This review explores this and other connections between large deviation theory and statistical mechanics, in an effort to show that the mathematical language of statistical mechanics is the language of large deviation theory. The first part of the review presents the basics of large deviation theory, and works out many of its classical applications related to sums of random variables and Markov processes. The second part goes through many problems and results of statistical mechanics, and shows how these can be formulated and derived within the context of large deviation theory. The problems and results treated cover a wide range of physical systems, including equilibrium many-particle systems, noise-perturbed dynamics, nonequilibrium systems, as well as multifractals, disordered systems, and chaotic systems. This review also covers many fundamental aspects of statistical mechanics, such as the derivation of variational principles characterizing equilibrium and nonequilibrium states, the breaking of the Legendre transform for nonconcave entropies, and the characterization of nonequilibrium fluctuations through fluctuation relations.

  16. The large deviation approach to statistical mechanics

    Science.gov (United States)

    Touchette, Hugo

    2009-07-01

    The theory of large deviations is concerned with the exponential decay of probabilities of large fluctuations in random systems. These probabilities are important in many fields of study, including statistics, finance, and engineering, as they often yield valuable information about the large fluctuations of a random system around its most probable state or trajectory. In the context of equilibrium statistical mechanics, the theory of large deviations provides exponential-order estimates of probabilities that refine and generalize Einstein’s theory of fluctuations. This review explores this and other connections between large deviation theory and statistical mechanics, in an effort to show that the mathematical language of statistical mechanics is the language of large deviation theory. The first part of the review presents the basics of large deviation theory, and works out many of its classical applications related to sums of random variables and Markov processes. The second part goes through many problems and results of statistical mechanics, and shows how these can be formulated and derived within the context of large deviation theory. The problems and results treated cover a wide range of physical systems, including equilibrium many-particle systems, noise-perturbed dynamics, nonequilibrium systems, as well as multifractals, disordered systems, and chaotic systems. This review also covers many fundamental aspects of statistical mechanics, such as the derivation of variational principles characterizing equilibrium and nonequilibrium states, the breaking of the Legendre transform for nonconcave entropies, and the characterization of nonequilibrium fluctuations through fluctuation relations.

  17. Measurement of left ventricular volume by biplane cine magnetic resonance imaging in children

    Energy Technology Data Exchange (ETDEWEB)

    Ichida, Fukiko; Hamamichi, Yuuji; Hashimoto, Ikuo; Tsubata, Shinichi; Miyazaki, Ayumi; Okada, Toshio; Murakami, Arata; Futatsuya, Ryuusuke (Toyama Medical and Pharmaceutical Univ. (Japan))

    1993-09-01

    To determine the ability of cine magnetic resonance imaging (MRI) to assess left ventricular (LV) volumes, we studied 20 children (age 4 months to 10 years) with various heart disease, validated by comparison with biplane LV angiography. Previous MRI studies to assess LV volumes have used multiple axial planes, which are compromised by partial volume effects and are time consuming to acquire and analyze. Accordingly, an imaging approach using biplane cine MRI and planes aligned with the true cardiac axes (the intrinsic long and short axis) of the LV was developed in views comparable with biplane LV angiography. In all patients, LV volumes were calculated by a Simpson's rule algorithm, both in MRI and LV angiography. MRI determined LV volumes were slightly underestimated but correlated reasonably well with angiographic values (LVEDV: Y=0.88X + 1.58, R=0.98, LVESV: Y=0.72X + 1.02, R=0.98). Especially, even in the patients who have abnormal left ventricular geometry such as Tetralogy of Fallot, MRI determined LV volumes correlated well with angiographic values. It is concluded that biplane cine MRI, using the intrinsic LV long and short axis planes, permits noninvasive assessment of LV volumes in views comparable to standard angiographic projections and appears practical for clinical use in childhood heart disease, because the scan and analysis time are relatively short. (author).

  18. Measurement of left ventricular volume by biplane cine magnetic resonance imaging in children

    Energy Technology Data Exchange (ETDEWEB)

    Ichida, Fukiko; Hamamichi, Yuuji; Hashimoto, Ikuo; Tsubata, Shinichi; Miyazaki, Ayumi; Okada, Toshio; Murakami, Arata; Futatsuya, Ryuusuke [Toyama Medical and Pharmaceutical Univ. (Japan)

    1993-09-01

    To determine the ability of cine magnetic resonance imaging (MRI) to assess left ventricular (LV) volumes, we studied 20 children (age 4 months to 10 years) with various heart disease, validated by comparison with biplane LV angiography. Previous MRI studies to assess LV volumes have used multiple axial planes, which are compromised by partial volume effects and are time consuming to acquire and analyze. Accordingly, an imaging approach using biplane cine MRI and planes aligned with the true cardiac axes (the intrinsic long and short axis) of the LV was developed in views comparable with biplane LV angiography. In all patients, LV volumes were calculated by a Simpson's rule algorithm, both in MRI and LV angiography. MRI determined LV volumes were slightly underestimated but correlated reasonably well with angiographic values (LVEDV: Y=0.88X + 1.58, R=0.98, LVESV: Y=0.72X + 1.02, R=0.98). Especially, even in the patients who have abnormal left ventricular geometry such as Tetralogy of Fallot, MRI determined LV volumes correlated well with angiographic values. It is concluded that biplane cine MRI, using the intrinsic LV long and short axis planes, permits noninvasive assessment of LV volumes in views comparable to standard angiographic projections and appears practical for clinical use in childhood heart disease, because the scan and analysis time are relatively short. (author).

  19. Measurement of left ventricular volume by biplane cine magnetic resonance imaging in children

    International Nuclear Information System (INIS)

    Ichida, Fukiko; Hamamichi, Yuuji; Hashimoto, Ikuo; Tsubata, Shinichi; Miyazaki, Ayumi; Okada, Toshio; Murakami, Arata; Futatsuya, Ryuusuke

    1993-01-01

    To determine the ability of cine magnetic resonance imaging (MRI) to assess left ventricular (LV) volumes, we studied 20 children (age 4 months to 10 years) with various heart disease, validated by comparison with biplane LV angiography. Previous MRI studies to assess LV volumes have used multiple axial planes, which are compromised by partial volume effects and are time consuming to acquire and analyze. Accordingly, an imaging approach using biplane cine MRI and planes aligned with the true cardiac axes (the intrinsic long and short axis) of the LV was developed in views comparable with biplane LV angiography. In all patients, LV volumes were calculated by a Simpson's rule algorithm, both in MRI and LV angiography. MRI determined LV volumes were slightly underestimated but correlated reasonably well with angiographic values (LVEDV: Y=0.88X + 1.58, R=0.98, LVESV: Y=0.72X + 1.02, R=0.98). Especially, even in the patients who have abnormal left ventricular geometry such as Tetralogy of Fallot, MRI determined LV volumes correlated well with angiographic values. It is concluded that biplane cine MRI, using the intrinsic LV long and short axis planes, permits noninvasive assessment of LV volumes in views comparable to standard angiographic projections and appears practical for clinical use in childhood heart disease, because the scan and analysis time are relatively short. (author)

  20. Transport Coefficients from Large Deviation Functions

    OpenAIRE

    Gao, Chloe Ya; Limmer, David T.

    2017-01-01

    We describe a method for computing transport coefficients from the direct evaluation of large deviation functions. This method is general, relying on only equilibrium fluctuations, and is statistically efficient, employing trajectory based importance sampling. Equilibrium fluctuations of molecular currents are characterized by their large deviation functions, which are scaled cumulant generating functions analogous to the free energies. A diffusion Monte Carlo algorithm is used to evaluate th...

  1. Binge-pattern alcohol exposure during puberty induces long-term changes in HPA axis reactivity.

    Directory of Open Access Journals (Sweden)

    Magdalena M Przybycien-Szymanska

    2011-04-01

    Full Text Available Adolescence is a dynamic and important period of brain development however, little is known about the long-term neurobiological consequences of alcohol consumption during puberty. Our previous studies showed that binge-pattern ethanol (EtOH treatment during pubertal development negatively dysregulated the responsiveness of the hypothalamo-pituitary-adrenal (HPA axis, as manifested by alterations in corticotrophin-releasing hormone (CRH, arginine vasopressin (AVP, and corticosterone (CORT during this time period. Thus, the primary goal of this study was to determine whether these observed changes in important central regulators of the stress response were permanent or transient. In this study, juvenile male Wistar rats were treated with a binge-pattern EtOH treatment paradigm or saline alone for 8 days. The animals were left undisturbed until adulthood when they received a second round of treatments consisting of saline alone, a single dose of EtOH, or a second binge-pattern treatment paradigm. The results showed that pubertal binge-pattern EtOH exposure induced striking long-lasting alterations of many HPA axis parameters. Overall, our data provide strong evidence that binge-pattern EtOH exposure during pubertal maturation has long-term detrimental effects for the healthy development of the HPA axis.

  2. Anatomical variation of celiac axis, superior mesenteric artery, and hepatic artery: Evaluation with multidetector computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Maryam Farghadani

    2016-01-01

    Full Text Available Background: The celiac axis, superior mesenteric artery (SMA, and hepatic artery are the most important branches of abdominal aorta due to their vascularization field. The aim of our study was to evaluate the prevalence of different anatomical variation of celiac axis, SMA, hepatic artery, and its branches with multidetector computed tomography (MDCT angiography of upper abdomen arteries. Materials and Methods: MDCT of 607 kidney donor and traumatic patients that referred to MDCT unit at Al Zahra Hospital in Isfahan from 2012 to 2015 were retrospectively evaluated. We excluded patients with history of abdominal vascular surgery and hepatic or pancreatic surgery. Computed tomography images of the patient were obtained with 64-row MDCT scanner and anatomical variations were analyzed. Results: Three hundred and eighty-eight (63.9% of the 607 patients had classic arterial anatomy and 219 (36.1% patients had variant types. The most common type of variation was the origin of the right hepatic artery (RHA from SMA (9.6%, and the next common variation was the origin of the left hepatic artery (LHA from the left gastric artery (6.9%. Variations in the origin of the common hepatic artery (CHA were seen in 16 (2.6% patients. Buhler arc was identified in two patients. The RHA originated from the celiac axis in 11 (1.8% patients and from the aorta in 8 (1.3% patients. Trifurcation of CHA into gastroduodenal artery, RHA, and LHA was detected in 11 (1.8% patients. Conclusion: The results of the present study showed that anatomical variation occurs in a high percentage of patients. Detection of these variations can guide surgical and radiological interventional planning.

  3. Tail-constraining stochastic linear–quadratic control: a large deviation and statistical physics approach

    International Nuclear Information System (INIS)

    Chertkov, Michael; Kolokolov, Igor; Lebedev, Vladimir

    2012-01-01

    The standard definition of the stochastic risk-sensitive linear–quadratic (RS-LQ) control depends on the risk parameter, which is normally left to be set exogenously. We reconsider the classical approach and suggest two alternatives, resolving the spurious freedom naturally. One approach consists in seeking for the minimum of the tail of the probability distribution function (PDF) of the cost functional at some large fixed value. Another option suggests minimizing the expectation value of the cost functional under a constraint on the value of the PDF tail. Under the assumption of resulting control stability, both problems are reduced to static optimizations over a stationary control matrix. The solutions are illustrated using the examples of scalar and 1D chain (string) systems. The large deviation self-similar asymptotic of the cost functional PDF is analyzed. (paper)

  4. left-angle 100 right-angle Burgers vector in single phase γ' material verified by image simulation

    International Nuclear Information System (INIS)

    Link, T.; Knobloch, C.; Glatzel, U.

    1998-01-01

    The deformation mechanisms of Ni 3 Al, an ordered L1 2 or γ' phase, is under intense research since Westbrook showed the increase of its hardness with temperature in 1957. The super dislocations of this ordered phase normally have Burgers vectors rvec b = a left-angle 110 right-angle, disassociated in either two a/2 left-angle 110 right-angle or two rvec b = a/3 left-angle 112 right-angle, depending on deformation temperature and rate. Recent observations in [111] oriented γ' specimens suggest that additional dislocations with the shorter Burgers vector rvec b = a left-angle 100 right-angle might be active. Dislocations with rvec b = a left-angle 110 right-angle on cube glide planes have a Schmidt factor of 0.47 and on octahedral planes of 0.27. Dislocations with rvec b = a left-angle 100 right-angle have a Schmidt factor of 0.47 for {110} glide planes and 0.33 for cube glide planes. The a left-angle 100 right-angle Burgers vector is the shortest of all complete dislocations of the L1 2 structure and creates no planar fault like antiphase boundaries or stacking faults. Due to the [111] oriented stress axis, which is used in this contribution, plastic deformation by a left-angle 100 right-angle dislocations as well as cube glide planes for left-angle 110 right-angle dislocations is encouraged. These dislocations could be reaction products, but will soon after contribute to deformation

  5. Towards a large deviation theory for strongly correlated systems

    International Nuclear Information System (INIS)

    Ruiz, Guiomar; Tsallis, Constantino

    2012-01-01

    A large-deviation connection of statistical mechanics is provided by N independent binary variables, the (N→∞) limit yielding Gaussian distributions. The probability of n≠N/2 out of N throws is governed by e −Nr , r related to the entropy. Large deviations for a strong correlated model characterized by indices (Q,γ) are studied, the (N→∞) limit yielding Q-Gaussians (Q→1 recovers a Gaussian). Its large deviations are governed by e q −Nr q (∝1/N 1/(q−1) , q>1), q=(Q−1)/(γ[3−Q])+1. This illustration opens the door towards a large-deviation foundation of nonextensive statistical mechanics. -- Highlights: ► We introduce the formalism of relative entropy for a single random binary variable and its q-generalization. ► We study a model of N strongly correlated binary random variables and their large-deviation probabilities. ► Large-deviation probability of strongly correlated model exhibits a q-exponential decay whose argument is proportional to N, as extensivity requires. ► Our results point to a q-generalized large deviation theory and suggest a large-deviation foundation of nonextensive statistical mechanics.

  6. FINDING STANDARD DEVIATION OF A FUZZY NUMBER

    OpenAIRE

    Fokrul Alom Mazarbhuiya

    2017-01-01

    Two probability laws can be root of a possibility law. Considering two probability densities over two disjoint ranges, we can define the fuzzy standard deviation of a fuzzy variable with the help of the standard deviation two random variables in two disjoint spaces.

  7. The error analysis of field size variation in pelvis region by using immobilization device

    International Nuclear Information System (INIS)

    Kim, Ki Hwan; Kang, No Hyun; Kim, Dong Wuk; Kim, Jun Sang; Jang, Ji Young; Kim, Jae Sung; Kim, Yong Eun; Cho, Moon June

    2000-01-01

    In radiotherapy, it may happen to radiate surrounding normal tissue because of inconsistent field size by changing patient position during treatment. We are going to analyze errors reduced by using immobilization device with Electronic Portal Imaging Device(EPID) in this study. We had treated the twenty-one patients in pelvic region with 10 MV X-ray from Aug. 1998 to Aug. 1999 at chungnam National University Hospital. All patients were treated at supine position during treatment. They were separated to two groups, 11 patients without device and 10 patients with immobilization device. We used styrofoam for immobilization device and measured the error of anterior direction for x, y axis and lateral direction for z, y axis from simulation film to EPID image using matching technique. For no immobilization device group, the mean deviation values of x axis and y axis are 0.19 mm. 0.48 mm, respectively and the standard deviations of systematic deviation are 2.38 mm, 2.19 mm, respectively and of random deviation for x axis and y axis are 1.92 mm. 1.29 mm, respectively. The mean deviation values of z axis and y axis are -3.61 mm. 2.07 mm, respectively and the standard deviations of systematic deviation are 3.20 mm, 2.29 mm, respectively and of random deviation for z axis and y axis are 2.73 mm. 1.62 mm, respectively. For immobilization device group, the mean deviation values of x axis and y axis are 0.71 mm. -1.07 mm, respectively and the standard deviations of systematic deviation are 1.80 mm, 2.26 mm, respectively and the standard deviations of systematic deviation are 1.80 mm, 2.26 mm, respectively of random deviation for x axis and y axis are 1.56 mm. 1.27 mm, respectively. The mean deviation values of z axis and y axis are -1.76 mm. 1.08 mm, respectively and the standard deviations of systematic deviation are 1.87 mm, 2.83 mm, respectively and of random deviation for x axis and y axis are 1.68 mm, 1.65 mm, respectively. Because of reducing random and systematic error

  8. Assessment of left ventricular hemodynamics by Gd-DTPA enhanced high speed cine MRI

    International Nuclear Information System (INIS)

    Matsumura, Kentaro; Nakase, Emiko; Kawai, Ichiro

    1992-01-01

    To assess the validity of Gd-DTPA enhanced high speed cine MRI in left ventricular (LV) volumes and ejection fraction (EF), high speed cine MRI was compared with intra-venous digital subtraction left ventriculography (IV-DSA) in 14 patients. All patients underwent conventional cine MRI and Gd-DTPA enhanced high speed MRI, simultaneously. The pulse sequences of high speed MRI were TR 8 ms (TR 6 ms plus rewind pulse 2 ms), TE 3.2 ms, matrix 128, phase encode 8 or 6 and NEX 1. Comparison with LV-volume showed a high correlation (y = 0.854x + 1,699, r = 0.985) between high speed cine MRI and VI-DSA. To make left ventricular volume curve by area-length method in cine MRI, manual tracing of LV-cavity was more difficult in conventional cine MRI-method than enhanced high speed cine MRI-method. In conclusion, first pass-Gd-DTPA enhanced high speed cine MRI, using the horizontal long axis approach and the multiphase study, is a highly, accurate reproducible method of evaluating LV-volumetry. (author)

  9. Regional left ventricular myocardial contraction abnormalities and asynchrony in patients with hypertrophic cardiomyopathy evaluated by magnetic resonance spatial modulation of magnetization myocardial tagging

    International Nuclear Information System (INIS)

    Mishiro, Yuichiro; Oki, Takashi; Iuchi, Arata

    1999-01-01

    Global left ventricular (LV) pump function is generally preserved in patients with hypertrophic cardiomyopathy (HCM). However, it is unknown whether regional myocardial contractility is impaired, especially in nonhypertrophied regions. The purpose of this study was to evaluate regional LV myocardial contraction in patients with HCM using magnetic resonance (MR) spatial modulation of magnetization (SPAMM) myocardial tagging. The study group comprised 20 patients with asymmetric septal hypertrophy (HCM group) and 16 age-matched normal patients (control group), and data were collected using transthoracic M-mode and 2-dimensional echocardiography, and MR SPAMM myocardial tagging. The systolic strain ratio, maximum systolic strain velocity, and time from end-diastole to maximum systolic strain (ΔT) in the anterior, ventricular septal, inferior and lateral regions for 2 LV short-axis sections at the levels of the chordae tendineae and papillary muscles were measured at 50-ms intervals by MR myocardial tagging. The end-diastolic anterior and ventricular septal wall thicknesses and LV mass index were significantly different between the HCM and control groups. The systolic strain ratio for all 4 walls, particularly the anterior and ventricular septal regions, was significantly lower in the HCM group. In the HCM group, the maximum systolic strain velocity was significantly lower and ΔT was significantly shorter for all 4 walls, particularly the anterior and ventricular septal regions. The standard deviation for the ΔT, calculated from the ΔT for the 8 regions of the 2 LV short-axis sections, was significantly greater in the HCM group. In conclusion, regional LV myocardial contraction is impaired in both hypertrophied and nonhypertrophied regions, and systolic LV wall asynchrony occurs in patients with HCM. (author)

  10. Prevalence of the different Axis I clinical subtypes in a sample of patients with orofacial pain and temporomandibular disorders in the Andalusian Healthcare Service

    Science.gov (United States)

    Blanco-Aguilera, Antonio; Blanco-Aguilera, Elena; Serrano-del-Rosal, Rafael; Biedma-Velázquez, Lourdes; Rodríguez-Torronteras, Alejandro; Segura-Saint-Gerons, Rafael

    2016-01-01

    Background The main objective of this paper is to analyze the prevalence of each of the different clinical subtypes of temporomandibular disorders (TMD) in a sample of patients with this pathology. In addition, a second objective was to analyze their distribution according to gender. Material and Methods To this end, the results of 1603 patients who went to the Unit of Temporomandibular Disorders in the Córdoba Healthcare District because they suffered from this pathology were analyzed. In order to diagnose them, the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) were applied, analyzing the different Axis I subtypes (myopathy, discopathy and arthropathy) and obtaining the combined Axis I for each patient and the relation of all these variables according to gender. The null-hypothesis test confirmed the lack of connection between the gender variable and the different subtypes in the clinical analysis, and between the former and the combined Axis I of the RDC/TMD. Results The prevalence was high for the muscle disorders subtype in general, showing an 88.7% prevalence, while the presence of discopathies or arthropathies was much lower. Among discopathies, the most frequent ones were disc displacements with reduction, with 39.7% and 42.8% for the left and right temporomandibular joints (TMJ), respectively, while the prevalence of arthropathies was 26.3% for the right TMJ and 32.9% for the left TMJ. The bivariate analysis on the connection with gender reveals a p≥ 0.05 value for the muscle and arthralgia subtypes. Conclusions The patients seen at the TMD Unit where mostly middle-aged women whose main clinical axis subtype was the muscle disorder subtype. For their part, both discopathies and arthropathies, although present, are much less prevalent. Key words:RDCTMD, axis I, orofacial pain, temporomandibular disorders, gender. PMID:26615508

  11. The large deviations theorem and ergodicity

    International Nuclear Information System (INIS)

    Gu Rongbao

    2007-01-01

    In this paper, some relationships between stochastic and topological properties of dynamical systems are studied. For a continuous map f from a compact metric space X into itself, we show that if f satisfies the large deviations theorem then it is topologically ergodic. Moreover, we introduce the topologically strong ergodicity, and prove that if f is a topologically strongly ergodic map satisfying the large deviations theorem then it is sensitively dependent on initial conditions

  12. Large deviations

    CERN Document Server

    Deuschel, Jean-Dominique; Deuschel, Jean-Dominique

    2001-01-01

    This is the second printing of the book first published in 1988. The first four chapters of the volume are based on lectures given by Stroock at MIT in 1987. They form an introduction to the basic ideas of the theory of large deviations and make a suitable package on which to base a semester-length course for advanced graduate students with a strong background in analysis and some probability theory. A large selection of exercises presents important material and many applications. The last two chapters present various non-uniform results (Chapter 5) and outline the analytic approach that allow

  13. Large deviations of the maximum eigenvalue in Wishart random matrices

    International Nuclear Information System (INIS)

    Vivo, Pierpaolo; Majumdar, Satya N; Bohigas, Oriol

    2007-01-01

    We analytically compute the probability of large fluctuations to the left of the mean of the largest eigenvalue in the Wishart (Laguerre) ensemble of positive definite random matrices. We show that the probability that all the eigenvalues of a (N x N) Wishart matrix W = X T X (where X is a rectangular M x N matrix with independent Gaussian entries) are smaller than the mean value (λ) = N/c decreases for large N as ∼exp[-β/2 N 2 Φ - (2√c + 1: c)], where β = 1, 2 corresponds respectively to real and complex Wishart matrices, c = N/M ≤ 1 and Φ - (x; c) is a rate (sometimes also called large deviation) function that we compute explicitly. The result for the anti-Wishart case (M < N) simply follows by exchanging M and N. We also analytically determine the average spectral density of an ensemble of Wishart matrices whose eigenvalues are constrained to be smaller than a fixed barrier. Numerical simulations are in excellent agreement with the analytical predictions

  14. Large deviations of the maximum eigenvalue in Wishart random matrices

    Energy Technology Data Exchange (ETDEWEB)

    Vivo, Pierpaolo [School of Information Systems, Computing and Mathematics, Brunel University, Uxbridge, Middlesex, UB8 3PH (United Kingdom) ; Majumdar, Satya N [Laboratoire de Physique Theorique et Modeles Statistiques (UMR 8626 du CNRS), Universite Paris-Sud, Batiment 100, 91405 Orsay Cedex (France); Bohigas, Oriol [Laboratoire de Physique Theorique et Modeles Statistiques (UMR 8626 du CNRS), Universite Paris-Sud, Batiment 100, 91405 Orsay Cedex (France)

    2007-04-20

    We analytically compute the probability of large fluctuations to the left of the mean of the largest eigenvalue in the Wishart (Laguerre) ensemble of positive definite random matrices. We show that the probability that all the eigenvalues of a (N x N) Wishart matrix W = X{sup T}X (where X is a rectangular M x N matrix with independent Gaussian entries) are smaller than the mean value ({lambda}) = N/c decreases for large N as {approx}exp[-{beta}/2 N{sup 2}{phi}{sub -} (2{radical}c + 1: c)], where {beta} = 1, 2 corresponds respectively to real and complex Wishart matrices, c = N/M {<=} 1 and {phi}{sub -}(x; c) is a rate (sometimes also called large deviation) function that we compute explicitly. The result for the anti-Wishart case (M < N) simply follows by exchanging M and N. We also analytically determine the average spectral density of an ensemble of Wishart matrices whose eigenvalues are constrained to be smaller than a fixed barrier. Numerical simulations are in excellent agreement with the analytical predictions.

  15. PoDMan: Policy Deviation Management

    Directory of Open Access Journals (Sweden)

    Aishwarya Bakshi

    2017-07-01

    Full Text Available Whenever an unexpected or exceptional situation occurs, complying with the existing policies may not be possible. The main objective of this work is to assist individuals and organizations to decide in the process of deviating from policies and performing a non-complying action. The paper proposes utilizing software agents as supportive tools to provide the best non-complying action while deviating from policies. The article also introduces a process in which the decision on the choice of non-complying action can be made. The work is motivated by a real scenario observed in a hospital in Norway and demonstrated through the same settings.

  16. Non-compact left ventricle/hypertrabeculated left ventricle

    International Nuclear Information System (INIS)

    Restrepo, Gustavo; Castano, Rafael; Marmol, Alejandro

    2005-01-01

    Non-compact left ventricle/hypertrabeculated left ventricle is a myocardiopatie produced by an arrest of the normal left ventricular compaction process during the early embryogenesis. It is associated to cardiac anomalies (congenital cardiopaties) as well as to extracardial conditions (neurological, facial, hematologic, cutaneous, skeletal and endocrinological anomalies). This entity is frequently unnoticed, being diagnosed only in centers with great experience in the diagnosis and treatment of myocardiopathies. Many cases of non-compact left ventricle have been initially misdiagnosed as hypertrophic myocardiopatie, endocardial fibroelastosis, dilated cardiomyopatie, restrictive cardiomyopathy and endocardial fibrosis. It is reported the case of a 74 years old man with a history of chronic arterial hypertension and diabetes mellitus, prechordial chest pain and mild dyspnoea. An echocardiogram showed signs of non-compact left ventricle with prominent trabeculations and deep inter-trabecular recesses involving left ventricular apical segment and extending to the lateral and inferior walls. Literature on this topic is reviewed

  17. Quantum uncertainty relation based on the mean deviation

    OpenAIRE

    Sharma, Gautam; Mukhopadhyay, Chiranjib; Sazim, Sk; Pati, Arun Kumar

    2018-01-01

    Traditional forms of quantum uncertainty relations are invariably based on the standard deviation. This can be understood in the historical context of simultaneous development of quantum theory and mathematical statistics. Here, we present alternative forms of uncertainty relations, in both state dependent and state independent forms, based on the mean deviation. We illustrate the robustness of this formulation in situations where the standard deviation based uncertainty relation is inapplica...

  18. Exploring Students' Conceptions of the Standard Deviation

    Science.gov (United States)

    delMas, Robert; Liu, Yan

    2005-01-01

    This study investigated introductory statistics students' conceptual understanding of the standard deviation. A computer environment was designed to promote students' ability to coordinate characteristics of variation of values about the mean with the size of the standard deviation as a measure of that variation. Twelve students participated in an…

  19. Automatic segmentation of the left ventricle in a cardiac MR short axis image using blind morphological operation

    Science.gov (United States)

    Irshad, Mehreen; Muhammad, Nazeer; Sharif, Muhammad; Yasmeen, Mussarat

    2018-04-01

    Conventionally, cardiac MR image analysis is done manually. Automatic examination for analyzing images can replace the monotonous tasks of massive amounts of data to analyze the global and regional functions of the cardiac left ventricle (LV). This task is performed using MR images to calculate the analytic cardiac parameter like end-systolic volume, end-diastolic volume, ejection fraction, and myocardial mass, respectively. These analytic parameters depend upon genuine delineation of epicardial, endocardial, papillary muscle, and trabeculations contours. In this paper, we propose an automatic segmentation method using the sum of absolute differences technique to localize the left ventricle. Blind morphological operations are proposed to segment and detect the LV contours of the epicardium and endocardium, automatically. We test the benchmark Sunny Brook dataset for evaluation of the proposed work. Contours of epicardium and endocardium are compared quantitatively to determine contour's accuracy and observe high matching values. Similarity or overlapping of an automatic examination to the given ground truth analysis by an expert are observed with high accuracy as with an index value of 91.30% . The proposed method for automatic segmentation gives better performance relative to existing techniques in terms of accuracy.

  20. Aeroelastically coupled blades for vertical axis wind turbines

    Science.gov (United States)

    Paquette, Joshua; Barone, Matthew F.

    2016-02-23

    Various technologies described herein pertain to a vertical axis wind turbine blade configured to rotate about a rotation axis. The vertical axis wind turbine blade includes at least an attachment segment, a rear swept segment, and optionally, a forward swept segment. The attachment segment is contiguous with the forward swept segment, and the forward swept segment is contiguous with the rear swept segment. The attachment segment includes a first portion of a centroid axis, the forward swept segment includes a second portion of the centroid axis, and the rear swept segment includes a third portion of the centroid axis. The second portion of the centroid axis is angularly displaced ahead of the first portion of the centroid axis and the third portion of the centroid axis is angularly displaced behind the first portion of the centroid axis in the direction of rotation about the rotation axis.

  1. Two examples of non strictly convex large deviations

    OpenAIRE

    De Marco, Stefano; Jacquier, Antoine; Roome, Patrick

    2016-01-01

    We present two examples of a large deviations principle where the rate function is not strictly convex. This is motivated by a model used in mathematical finance (the Heston model), and adds a new item to the zoology of non strictly convex large deviations. For one of these examples, we show that the rate function of the Cramer-type of large deviations coincides with that of the Freidlin-Wentzell when contraction principles are applied.

  2. A Visual Model for the Variance and Standard Deviation

    Science.gov (United States)

    Orris, J. B.

    2011-01-01

    This paper shows how the variance and standard deviation can be represented graphically by looking at each squared deviation as a graphical object--in particular, as a square. A series of displays show how the standard deviation is the size of the average square.

  3. Design Of Single-Axis And Dual-Axis Solar Tracking Systems Protected Against High Wind Speeds

    Directory of Open Access Journals (Sweden)

    Mai Salaheldin Elsherbiny

    2017-09-01

    Full Text Available Solar energy is rapidly gaining ground as an important mean of expanding renewable energy use. Solar tracking is employed in order to maximize collected solar radiation by a photovoltaic panel. In this paper we present a prototype for Automatic solar tracker that is designed using Arduino UNO with Wind sensor to Cease Wind effect on panels if wind speed exceeds certain threshold. The Proposed solar tracker tracks the location of the sun anywhere in any time by calculating the position of the sun. For producing the maximum amount of solar energy a solar panel must always be perpendicular to the source of light. Because the sun motion plane varies daily and during the day it moves from east to west one needs two axis tracking to follow the suns position. Maximum possible power is collected when two axis tracking is done. However two axis tracking is relatively costly and complex. A compromise between maximum power collection and system simplicity is obtained by single axis tracking where the plane North south axis is fixed while the east west motion is accomplished. This work deals with the design of both single and two axis tracking systems. Automatic trackers is also compared to Fixed one in terms of Energy generated Efficiency Cost and System reliability.

  4. Left regular bands of groups of left quotients

    International Nuclear Information System (INIS)

    El-Qallali, A.

    1988-10-01

    A semigroup S which has a left regular band of groups as a semigroup of left quotients is shown to be the semigroup which is a left regular band of right reversible cancellative semigroups. An alternative characterization is provided by using spinned products. These results are applied to the case where S is a superabundant whose set of idempotents forms a left normal band. (author). 13 refs

  5. 7 CFR 400.204 - Notification of deviation from standards.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Notification of deviation from standards. 400.204... Contract-Standards for Approval § 400.204 Notification of deviation from standards. A Contractor shall advise the Corporation immediately if the Contractor deviates from the requirements of these standards...

  6. Detection of defects in formed sheet metal using medial axis transformation

    Science.gov (United States)

    Murmu, Naresh C.; Velgan, Roman

    2003-05-01

    In the metal forming processes, the sheet metals are often prone to various defects such as thinning, dents, wrinkles etc. In the present manufacturing environments with ever increasing demand of higher quality, detecting the defects of formed sheet metal using an effective and objective inspection system is the foremost norm to remain competitive in market. The defect detection using optical techniques aspire to satisfy its needs to be non-contact and fast. However, the main difficulties to achieve this goal remain essentially on the development of efficient evaluation technique and accurate interpretation of extracted data. The defect like thinning is detected by evaluating the deviations of the thickness in the formed sheet metal against its nominal value. The present evaluation procedure for determination of thickness applied on the measurements data is not without deficiency. To improve this procedure, a new evaluation approach based on medial axis transformation is proposed here. The formed sheet metals are digitized using fringe projection systems in different orientations, and afterwards registered into one coordinate frame. The medial axis transformation (MAT) is applied on the point clouds, generating the point clouds of MAT. This data is further processed and medial surface is determined. The thinning defect is detected by evaluating local wall thickness and other defects like wrinkles are determined using the shape recognition on the medial surface. The applied algorithm is simple, fast and robust.

  7. Theoretical tool movement required to diamond turn an off-axis paraboloid on axis

    International Nuclear Information System (INIS)

    Thompson, D.C.

    1976-01-01

    Current techniques for manufacturing off-axis paraboloids are both expensive and insufficiently accurate. An alternative method, turning the workpiece about its axis on a diamond-turning machine, is presented, and the equations describing the necessary tool movement are derived. A discussion of a particular case suggests that the proposed technique is feasible

  8. 21 CFR 330.11 - NDA deviations from applicable monograph.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false NDA deviations from applicable monograph. 330.11... EFFECTIVE AND NOT MISBRANDED Administrative Procedures § 330.11 NDA deviations from applicable monograph. A new drug application requesting approval of an OTC drug deviating in any respect from a monograph that...

  9. Value of transient dilation of the left ventricular cavity on stress thallium scintigraphy

    International Nuclear Information System (INIS)

    Sugihara, Hiroki; Shiga, Kouji; Umamoto, Ikuo

    1991-01-01

    This study was undertaken to evaluate the value of transient dilation of the left ventricular cavity on stress thallium scintigraphy in 80 patients with ischemic heart disease (IHD) and 50 with hypertrophic cardiomyopathy (HCM). Twenty persons without either coronary artery stenosis or heart disease were served as controls. Areas surrounded by maximum count points on the line of each 10deg on the short axis slice through the mid-cavity of the left ventricle were obtained at 10 minutes and at 3 hours after exercise. Transient dilation index (TDI) was obtained by dividing the area on early image by that on delayed image. TDI was significantly higher in patients with two or three vessel disease in the IHD group than the control group. High TDI was observed in 8% for one vessel disease, 40% for two vessel disease, and 80% for three vessel disease, contributing to the detection of multivessel IHD. In the HCM group of 80 patients, 24 (48%) had high TDI which was frequently associated with a history of chest pain and positive ECG findings at exercise. When these 24 HCM patients underwent exercise blood pool scintiscanning, left ventricular enddiastolic volume was similar before and at 10 minutes after exercise. These findings suggest that transient dilation of the left ventricular cavity after exercise may reflect subendocardial ischemia in both IHD and HCM. TDI would become a useful indicator for transient dilation of the left ventricular cavity. (N.K.)

  10. Sensitivity Analysis of Deviation Source for Fast Assembly Precision Optimization

    Directory of Open Access Journals (Sweden)

    Jianjun Tang

    2014-01-01

    Full Text Available Assembly precision optimization of complex product has a huge benefit in improving the quality of our products. Due to the impact of a variety of deviation source coupling phenomena, the goal of assembly precision optimization is difficult to be confirmed accurately. In order to achieve optimization of assembly precision accurately and rapidly, sensitivity analysis of deviation source is proposed. First, deviation source sensitivity is defined as the ratio of assembly dimension variation and deviation source dimension variation. Second, according to assembly constraint relations, assembly sequences and locating, deviation transmission paths are established by locating the joints between the adjacent parts, and establishing each part’s datum reference frame. Third, assembly multidimensional vector loops are created using deviation transmission paths, and the corresponding scalar equations of each dimension are established. Then, assembly deviation source sensitivity is calculated by using a first-order Taylor expansion and matrix transformation method. Finally, taking assembly precision optimization of wing flap rocker as an example, the effectiveness and efficiency of the deviation source sensitivity analysis method are verified.

  11. Theoretical tool movement required to diamond turn an off-axis paraboloid on axis

    International Nuclear Information System (INIS)

    Thompson, D.C.

    1975-01-01

    High-quality, off-axis parabolic reflectors, required by the CTR and laser-fusion programs at Lawrence Livermore Laboratory (LLL) and other ERDA laboratories, are currently manufactured by hand. There are several drawbacks to this method, including lead times of up to a year, costs in excess of dollars 75,000 for a small reflector, and unsatisfactory limits to the tolerances obtainable. This situation has led to a search for cheaper and more accurate methods of manufacturing off-axis paraboloids. An alternative method, turning the workpiece about its axis on a diamond-turning machine, is presented, and the equations describing the necessary tool movement are derived. A discussion of a particular case suggests that the proposed technique is feasible

  12. Diagnostic value of transient dilatation of the left ventricle in negative dipyridamole-thallium imaging

    International Nuclear Information System (INIS)

    Seo, Hiromi; Doi, Y.L.; Yonezawa, Yoshihiro; Chikamori, Taishiro; Yamada, Mitsutoshi; Ozawa, Toshio

    1994-01-01

    To evaluate the diagnostic value of a transient dilatation of the left ventricle during dipyridamole-thallium imaging (DTI) for detecting significant coronary artery disease (CAD) in patients with negative DTI results, 81 consecutive patients were studied. Twenty one patients (26%) had CAD and 60 patients had normal coronary anatomy (NCA). The initial/delayed ratio of the left ventricular dimension, which was measured as the distance between the 2 peaks of a count profile curve on a 45deg left anterior oblique planar image, was defined as the dilatation ratio (DR) of the left ventricle. Patients with CAD had a higher incidence of chest pain after dipyridamole infusion (35 vs 13%; p 1.03) when it was greater than the mean +2 standard deviations of the DR in NCA patients. Seventy-six percent of CAD patients had an abnormal DR. A stepwise discriminant analysis revealed that an abnormal DR alone had the same ability to predict CAD (sensitivity 76%, specificity 98%, chi-square 80.9, p 1.03) is a highly specific marker for detecting CAD, even in patients with negative dipyridamole-thallium imaging. (author)

  13. The use of two-axis high precision inclination sensors in determining headframe deflection

    Directory of Open Access Journals (Sweden)

    Jaśkowski Wojciech

    2018-01-01

    Full Text Available Reliability of transport equipment in the shaft depends, among other things, on the accuracy of the vertical foundation of the headframe together with elements of the hoisting equipment over the shaft. Any deviations beyond the installation and movement tolerances may cause incorrect or even dangerous operation of the hoisting equipment in the shaft. Therefore the headframe is subjected to periodic inventory measurements, which prevent the movement in the shaft and the smooth operation of the whole underground mine. The Wieliczka Salt Mine developed a project for the installation of precision Nivel 220 two-axis inclinometers on Kinga and Daniłowicz headframes. The paper summarizes the initial conclusions resulting from the first year of the system operation and indicates the directions of its development.

  14. UMAPRM: Uniformly sampling the medial axis

    KAUST Repository

    Yeh, Hsin-Yi Cindy

    2014-05-01

    © 2014 IEEE. Maintaining clearance, or distance from obstacles, is a vital component of successful motion planning algorithms. Maintaining high clearance often creates safer paths for robots. Contemporary sampling-based planning algorithms That utilize The medial axis, or The set of all points equidistant To Two or more obstacles, produce higher clearance paths. However, They are biased heavily Toward certain portions of The medial axis, sometimes ignoring parts critical To planning, e.g., specific Types of narrow passages. We introduce Uniform Medial Axis Probabilistic RoadMap (UMAPRM), a novel planning variant That generates samples uniformly on The medial axis of The free portion of Cspace. We Theoretically analyze The distribution generated by UMAPRM and show its uniformity. Our results show That UMAPRM\\'s distribution of samples along The medial axis is not only uniform but also preferable To other medial axis samplers in certain planning problems. We demonstrate That UMAPRM has negligible computational overhead over other sampling Techniques and can solve problems The others could not, e.g., a bug Trap. Finally, we demonstrate UMAPRM successfully generates higher clearance paths in The examples.

  15. Na(3p left-arrow 3s) excitation by impact of slow multiply charged ions

    International Nuclear Information System (INIS)

    Horvath, G.; Schweinzer, J.; Winter, H.; Aumayr, F.

    1996-01-01

    We present a systematic experimental and theoretical study of Na(3p left-arrow 3s) excitation by slow (v NaI with projectile ion charge state q is investigated. Due to the dominance of the competing electron capture channels at low collision energies E, the excitation cross sections deviate significantly from a commonly applied σ/q=f(E/q) cross-section scaling relation. copyright 1996 The American Physical Society

  16. Effect of nasal deviation on quality of life.

    Science.gov (United States)

    de Lima Ramos, Sueli; Hochman, Bernardo; Gomes, Heitor Carvalho; Abla, Luiz Eduardo Felipe; Veiga, Daniela Francescato; Juliano, Yara; Dini, Gal Moreira; Ferreira, Lydia Masako

    2011-07-01

    Nasal deviation is a common complaint in otorhinolaryngology and plastic surgery. This condition not only causes impairment of nasal function but also affects quality of life, leading to psychological distress. The subjective assessment of quality of life, as an important aspect of outcomes research, has received increasing attention in recent decades. Quality of life is measured using standardized questionnaires that have been tested for reliability, validity, and sensitivity. The aim of this study was to evaluate health-related quality of life, self-esteem, and depression in patients with nasal deviation. Sixty patients were selected for the study. Patients with nasal deviation (n = 32) were assigned to the study group, and patients without nasal deviation (n = 28) were assigned to the control group. The diagnosis of nasal deviation was made by digital photogrammetry. Quality of life was assessed using the Medical Outcomes Study 36-Item Short Form Health Survey questionnaire; the Rosenberg Self-Esteem/Federal University of São Paulo, Escola Paulista de Medicina Scale; and the 20-item Self-Report Questionnaire. There were significant differences between groups in the physical functioning and general health subscales of the Medical Outcomes Study 36-Item Short Form Health Survey (p < 0.05). Depression was detected in 11 patients (34.4 percent) in the study group and in two patients in the control group, with a significant difference between groups (p < 0.05). Nasal deviation is an aspect of rhinoplasty of which the surgeon should be aware so that proper psychological diagnosis can be made and suitable treatment can be planned because psychologically the patients with nasal deviation have significantly worse quality of life and are more prone to depression. Risk, II.(Figure is included in full-text article.).

  17. Association between septal deviation and sinonasal papilloma.

    Science.gov (United States)

    Nomura, Kazuhiro; Ogawa, Takenori; Sugawara, Mitsuru; Honkura, Yohei; Oshima, Hidetoshi; Arakawa, Kazuya; Oshima, Takeshi; Katori, Yukio

    2013-12-01

    Sinonasal papilloma is a common benign epithelial tumor of the sinonasal tract and accounts for 0.5% to 4% of all nasal tumors. The etiology of sinonasal papilloma remains unclear, although human papilloma virus has been proposed as a major risk factor. Other etiological factors, such as anatomical variations of the nasal cavity, may be related to the pathogenesis of sinonasal papilloma, because deviated nasal septum is seen in patients with chronic rhinosinusitis. We, therefore, investigated the involvement of deviated nasal septum in the development of sinonasal papilloma. Preoperative computed tomography or magnetic resonance imaging findings of 83 patients with sinonasal papilloma were evaluated retrospectively. The side of papilloma and the direction of septal deviation showed a significant correlation. Septum deviated to the intact side in 51 of 83 patients (61.4%) and to the affected side in 18 of 83 patients (21.7%). Straight or S-shaped septum was observed in 14 of 83 patients (16.9%). Even after excluding 27 patients who underwent revision surgery and 15 patients in whom the papilloma touched the concave portion of the nasal septum, the concave side of septal deviation was associated with the development of sinonasal papilloma (p = 0.040). The high incidence of sinonasal papilloma in the concave side may reflect the consequences of the traumatic effects caused by wall shear stress of the high-velocity airflow and the increased chance of inhaling viruses and pollutants. The present study supports the causative role of human papilloma virus and toxic chemicals in the occurrence of sinonasal papilloma.

  18. Hearing protector performance and standard deviation.

    Science.gov (United States)

    Williams, W; Dillon, H

    2005-01-01

    The attenuation performance of a hearing protector is used to estimate the protected exposure level of the user. The aim is to reduce the exposed level to an acceptable value. Users should expect the attenuation to fall within a reasonable range of values around a norm. However, an analysis of extensive test data indicates that there is a negative relationship between attenuation performance and the standard deviation. This result is deduced using a variation in the method of calculating a single number rating of attenuation that is more amenable to drawing statistical inferences. As performance is typically specified as a function of the mean attenuation minus one or two standard deviations from the mean to ensure that greater than 50% of the wearer population are well protected, the implication of increasing standard deviation with decreasing attenuation found in this study means that a significant number of users are, in fact, experiencing over-protection. These users may be disinclined to use their hearing protectors because of an increased feeling of acoustic isolation. This problem is exacerbated in areas with lower noise levels.

  19. Top Yukawa deviation in extra dimension

    International Nuclear Information System (INIS)

    Haba, Naoyuki; Oda, Kin-ya; Takahashi, Ryo

    2009-01-01

    We suggest a simple one-Higgs-doublet model living in the bulk of five-dimensional spacetime compactified on S 1 /Z 2 , in which the top Yukawa coupling can be smaller than the naive standard-model expectation, i.e. the top quark mass divided by the Higgs vacuum expectation value. If we find only single Higgs particle at the LHC and also observe the top Yukawa deviation, our scenario becomes a realistic candidate beyond the standard model. The Yukawa deviation comes from the fact that the wave function profile of the free physical Higgs field can become different from that of the vacuum expectation value, due to the presence of the brane-localized Higgs potentials. In the Brane-Localized Fermion scenario, we find sizable top Yukawa deviation, which could be checked at the LHC experiment, with a dominant Higgs production channel being the WW fusion. We also study the Bulk Fermion scenario with brane-localized Higgs potential, which resembles the Universal Extra Dimension model with a stable dark matter candidate. We show that both scenarios are consistent with the current electroweak precision measurements.

  20. Serotonin signaling is a very early step in patterning of the left-right axis in chick and frog embryos

    NARCIS (Netherlands)

    Fukumoto, T; Kema, IP; Levin, M

    2005-01-01

    Background: Consistent left-right (LR) asymmetry is a fascinating problem in developmental and evolutionary biology. Conservation of early LR patterning steps among vertebrates as well as involvement of nonprotein small-molecule messengers are very poorly understood. Serotonin (5-HT) is a key

  1. A Wnt5 Activity Asymmetry and Intercellular Signaling via PCP Proteins Polarize Node Cells for Left-Right Symmetry Breaking.

    Science.gov (United States)

    Minegishi, Katsura; Hashimoto, Masakazu; Ajima, Rieko; Takaoka, Katsuyoshi; Shinohara, Kyosuke; Ikawa, Yayoi; Nishimura, Hiromi; McMahon, Andrew P; Willert, Karl; Okada, Yasushi; Sasaki, Hiroshi; Shi, Dongbo; Fujimori, Toshihiko; Ohtsuka, Toshihisa; Igarashi, Yasunobu; Yamaguchi, Terry P; Shimono, Akihiko; Shiratori, Hidetaka; Hamada, Hiroshi

    2017-03-13

    Polarization of node cells along the anterior-posterior axis of mouse embryos is responsible for left-right symmetry breaking. How node cells become polarized has remained unknown, however. Wnt5a and Wnt5b are expressed posteriorly relative to the node, whereas genes for Sfrp inhibitors of Wnt signaling are expressed anteriorly. Here we show that polarization of node cells is impaired in Wnt5a -/- Wnt5b -/- and Sfrp mutant embryos, and also in the presence of a uniform distribution of Wnt5a or Sfrp1, suggesting that Wnt5 and Sfrp proteins act as instructive signals in this process. The absence of planar cell polarity (PCP) core proteins Prickle1 and Prickle2 in individual cells or local forced expression of Wnt5a perturbed polarization of neighboring wild-type cells. Our results suggest that opposing gradients of Wnt5a and Wnt5b and of their Sfrp inhibitors, together with intercellular signaling via PCP proteins, polarize node cells along the anterior-posterior axis for breaking of left-right symmetry. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Accuracy of various impression materials and methods for two implant systems: An effect size study.

    Science.gov (United States)

    Schmidt, Alexander; Häussling, Teresa; Rehmann, Peter; Schaaf, Heidrun; Wöstmann, Bernd

    2018-04-01

    An accurate impression is required for implant treatment. The aim of this in-vitro study was to determine the effect size of the impression material/method, implant system and implant angulation on impression transfer precision. An upper jaw model with three BEGO and three Straumann implants (angulations 0°, 15°, 20°) in the left and right maxilla was used as a reference model. One polyether (Impregum Penta) and two polyvinyl siloxanes (Flexitime Monophase/Aquasil Ultra Monophase) were examined with two impression techniques (open and closed tray). A total of 60 impressions were made. A coordinate measurement machine was used to measure the target variables for 3D-shift, implant axis inclination and implant axis rotation. All the data were subjected to a four-way ANOVA. The effect size (partial eta-squared [η 2 P ]) was reported. The impression material had a significant influence on the 3D shift and the implant axis inclination deviation (p-values=.000), and both factors had very large effect sizes (3D-shift [η 2 P ]=.599; implant axis inclination [η 2 P ]=.298). Impressions made with polyvinyl siloxane exhibited the highest transfer precision. When the angulation of the implants was larger, more deviations occurred for the implant axis rotational deviation. The implant systems and impression methods showed partially significant variations (p-values=.001-.639) but only very small effect sizes (η 2 P =.001-.031). The impression material had the greatest effect size on accuracy in terms of the 3D shift and the implant axis inclination. For multiunit restorations with disparallel implants, polyvinyl siloxane materials should be considered. In addition, the effect size of a multivariate investigation should be reported. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  3. ECG-Based Detection of Early Myocardial Ischemia in a Computational Model: Impact of Additional Electrodes, Optimal Placement, and a New Feature for ST Deviation.

    Science.gov (United States)

    Loewe, Axel; Schulze, Walther H W; Jiang, Yuan; Wilhelms, Mathias; Luik, Armin; Dössel, Olaf; Seemann, Gunnar

    2015-01-01

    In case of chest pain, immediate diagnosis of myocardial ischemia is required to respond with an appropriate treatment. The diagnostic capability of the electrocardiogram (ECG), however, is strongly limited for ischemic events that do not lead to ST elevation. This computational study investigates the potential of different electrode setups in detecting early ischemia at 10 minutes after onset: standard 3-channel and 12-lead ECG as well as body surface potential maps (BSPMs). Further, it was assessed if an additional ECG electrode with optimized position or the right-sided Wilson leads can improve sensitivity of the standard 12-lead ECG. To this end, a simulation study was performed for 765 different locations and sizes of ischemia in the left ventricle. Improvements by adding a single, subject specifically optimized electrode were similar to those of the BSPM: 2-11% increased detection rate depending on the desired specificity. Adding right-sided Wilson leads had negligible effect. Absence of ST deviation could not be related to specific locations of the ischemic region or its transmurality. As alternative to the ST time integral as a feature of ST deviation, the K point deviation was introduced: the baseline deviation at the minimum of the ST-segment envelope signal, which increased 12-lead detection rate by 7% for a reasonable threshold.

  4. Quasi-Rayleigh waves in transversely isotropic half-space with inclined axis of symmetry

    International Nuclear Information System (INIS)

    Yanovskaya, T.B.; Savina, L.S.

    2003-09-01

    A method for determination of characteristics of quasi-Rayleigh (qR) wave in a transversely isotropic homogeneous half-space with inclined axis of symmetry is outlined. The solution is obtained as a superposition of qP, qSV and qSH waves, and surface wave velocity is determined from the boundary conditions at the free surface and at infinity, as in the case of Rayleigh wave in isotropic half-space. Though the theory is simple enough, a numerical procedure for the calculation of surface wave velocity presents some difficulties. The difficulty is conditioned by necessity to calculate complex roots of a non-linear equation, which in turn contains functions determined as roots of nonlinear equations with complex coefficients. Numerical analysis shows that roots of the equation corresponding to the boundary conditions do not exist in the whole domain of azimuths and inclinations of the symmetry axis. The domain of existence of qR wave depends on the ratio of the elastic parameters: for some strongly anisotropic models the wave cannot exist at all. For some angles of inclination qR wave velocities deviate from those calculated on the basis of the perturbation method valid for weak anisotropy, though they have the same tendency of variation with azimuth. The phase of qR wave varies with depth unlike Rayleigh wave in isotropic half-space. Unlike Rayleigh wave in isotropic half-space, qR wave has three components - vertical, radial and transverse. Particle motion in horizontal plane is elliptic. Direction of the major axis of the ellipsis coincide with the direction of propagation only in azimuths 0 deg. (180 deg.) and 90 deg. (270 deg.). (author)

  5. Prosthodontic management of mandibular deviation using palatal ramp appliance

    Directory of Open Access Journals (Sweden)

    Prince Kumar

    2012-08-01

    Full Text Available Segmental resection of the mandible generally results in deviation of the mandible to the defective side. This loss of continuity of the mandible destroys the balance of the lower face and leads to decreased mandibular function by deviation of the residual segment toward the surgical site. Prosthetic methods advocated to reduce or eliminate mandibular deviation include intermaxillary fixation, removable mandibular guide flange, palatal ramp, implant-supported prosthesis and palatal guidance restorations which may be useful in reducing mandibular deviation and improving masticatory performance and efficiency. These methods and restorations would be combined with a well organized mandibular exercise regimen. This clinical report describes the rehabilitation following segmental mandibulectomy using palatal ramp prosthesis.

  6. Feasibility of free-breathing, GRAPPA-based, real-time cardiac cine assessment of left-ventricular function in cardiovascular patients at 3 T

    International Nuclear Information System (INIS)

    Zhu, Xiaomei; Schwab, Felix; Marcus, Roy; Hetterich, Holger; Theisen, Daniel; Kramer, Harald; Notohamiprodjo, Mike; Schlett, Christopher L.; Nikolaou, Konstantin; Reiser, Maximilian F.

    2015-01-01

    Highlights: • Grappa-based real time cine cardiac MRI is feasible for assessment of left ventricular function. • Significant underestimation of systolic function, peak ejection and filling rates needs to be considered. • Heart rate is the only positive predictor of the deviation of obtained parameters. - Abstract: Objectives: To determine the feasibility of free-breathing, GRAPPA-based, real-time (RT) cine 3 T cardiac magnetic resonance imaging (MRI) with high acceleration factors for the assessment of left-ventricular function in a cohort of patients as compared to conventional segmented cine imaging. Materials and methods: In this prospective cohort study, subjects with various cardiac conditions underwent MRI involving two RT cine sequences (high resolution and low resolution) and standard segmented cine imaging. Standard qualitative and quantitative parameters of left-ventricular function were quantified. Results: Among 25 subjects, 24 were included in the analysis (mean age: 50.5 ± 21 years, 67% male, 25% with cardiomyopathy). RT cine derived quantitative parameters of volumes and left ventricular mass were strongly correlated with segmented cine imaging (intraclass correlation coefficient [ICC]: >0.72 for both RT cines) but correlation for peak ejection and filling rates were moderate to poor for both RT cines (ICC < 0.40). Similarly, RT cines significantly underestimated peak ejection and filling rates (>103.2 ± 178 ml/s). Among patient-related factors, heart rate was strongly predictive for deviation of measurements (p < 0.05). Conclusions: RT cine MRI at 3 T is feasible for qualitative and quantitative assessment of left ventricular function for low and high-resolution sequences but results in significant underestimation of systolic function, peak ejection and filling rates

  7. Scaphoid and lunate movement in different ranges of carpal radioulnar deviation.

    Science.gov (United States)

    Tang, Jin Bo; Xu, Jing; Xie, Ren Guo

    2011-01-01

    We aimed to investigate scaphoid and lunate movement in radial deviation and in slight and moderate ulnar deviation ranges in vivo. We obtained computed tomography scans of the right wrists from 20° radial deviation to 40° ulnar deviation in 20° increments in 6 volunteers. The 3-dimensional bony structures of the wrist, including the distal radius and ulna, were reconstructed with customized software. The changes in position of the scaphoid and lunate along flexion-extension motion (FEM), radioulnar deviation (RUD), and supination-pronation axes in 3 parts--radial deviation and slight and moderate ulnar deviation--of the carpal RUD were calculated and analyzed. During carpal RUD, scaphoid and lunate motion along 3 axes--FEM, RUD, and supination-pronation--were the greatest in the middle third of the measured RUD (from neutral position to 20° ulnar deviation) and the smallest in radial deviation. Scaphoid motion along the FEM, RUD, and supination-pronation axes in the middle third was about half that in the entire motion range. In the middle motion range, lunate movement along the FEM and RUD axes was also the greatest. During carpal RUD, the greatest scaphoid and lunate movement occurs in the middle of the arc--slight ulnar deviation--which the wrist frequently adopts to accomplish major hand actions. At radial deviation, scaphoid and lunate motion is the smallest. Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  8. An absolute deviation approach to assessing correlation.

    OpenAIRE

    Gorard, S.

    2015-01-01

    This paper describes two possible alternatives to the more traditional Pearson’s R correlation coefficient, both based on using the mean absolute deviation, rather than the standard deviation, as a measure of dispersion. Pearson’s R is well-established and has many advantages. However, these newer variants also have several advantages, including greater simplicity and ease of computation, and perhaps greater tolerance of underlying assumptions (such as the need for linearity). The first alter...

  9. 38 CFR 36.4304 - Deviations; changes of identity.

    Science.gov (United States)

    2010-07-01

    ... identity. 36.4304 Section 36.4304 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS... Deviations; changes of identity. A deviation of more than 5 percent between the estimates upon which a... change in the identity of the property upon which the original appraisal was based, will invalidate the...

  10. Moderate deviations principles for the kernel estimator of ...

    African Journals Online (AJOL)

    Abstract. The aim of this paper is to provide pointwise and uniform moderate deviations principles for the kernel estimator of a nonrandom regression function. Moreover, we give an application of these moderate deviations principles to the construction of condence regions for the regression function. Resume. L'objectif de ...

  11. 48 CFR 1352.219-71 - Notification to delay performance (Deviation).

    Science.gov (United States)

    2010-10-01

    ... performance (Deviation). 1352.219-71 Section 1352.219-71 Federal Acquisition Regulations System DEPARTMENT OF....219-71 Notification to delay performance (Deviation). As prescribed in 48 CFR 1319.811-3(b), insert the following clause: Notification To Delay Performance (Deviation) (APR 2010) The contractor shall...

  12. 7 CFR 400.174 - Notification of deviation from financial standards.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Notification of deviation from financial standards... Agreement-Standards for Approval; Regulations for the 1997 and Subsequent Reinsurance Years § 400.174 Notification of deviation from financial standards. An insurer must immediately advise FCIC if it deviates from...

  13. The resting electrocardiogram of t. cruzi-infected rats

    Directory of Open Access Journals (Sweden)

    Reinaldo B. Bestetti

    1987-08-01

    Full Text Available A total of 125 rats were infected with the Colômbia strain of T. cruzi (2000 parasites/g shortly after weaning. Of these, 58 survived the acute phase and were used in the present experiment. Twenty eight similar but not infected rats served as controls. All rats were submitted to the resting ECG When they were 6 months old. Classic and 3 precordial leads were employed in order to record the ECG as completely as possible. Electrocardiographic changes similar to those found in human chronic Chagas' heart disease and not previously described in this model were found in 44% of the T. cruzi-infected rats: left axis deviation (22%, right axis deviation (7%, lengthened and bizarre QRS complex (14% and abnormal J point elevation (3%. On the basis of these results, we believe that the resting ECG constitutes a valuable tool for studying experimental chronic Chagas' heart disease in rats.

  14. Clinical usefulness of cine MRI for evaluation of left ventricular volume and diagnosis of heart and great vessel diseases

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, Takeshi; Anno, Hirofumi; Uritani, Tomizo [Fujita-Gakuen Health Univ., Toyoake, Aichi (Japan); and others

    1990-01-01

    ECG-gated cine mode magnetic resonance (MR) imaging was performed in 20 patients with various heart deseases. Left ventricular volume (LVV) and left ventricular ejection fraction (LVEF) were calculated on MR images obtained in left ventricular vertical and horizontal long axis views. The findings were compared with those obtained from left ventriculography. There was a significant positive correlation between MR imaging and ventriculography for both LVV and LVEF (p<0.001). In Marfan syndrome after surgery for dissecting aneurysm of the aorta, MR imaging was capable of visualizing not only the whole aorta in a single plane but also enlargement of the aortic root. It also depicted asynergy and thinned wall of the infarcted myocardium for myocardial infarction; an enlarged left auricle, the thickened septum, and constricted outflow tract for idiopathic hypertrophic subaortic stenosis; shunt flow for ventricular septum defect; and an enlarged aortic root for aortitis syndrome. Using ventriculography as the standard, cine MR imaging was frequently false positive for the detection of mitral regurgitation. There was, however, good concordance between MR imaging and ventriculography in detecting aortic regurgitation. In addition, MR imaging was equivalent to color Doppler technique for detecting valvular regurgitation. (N.K.).

  15. Clinical usefulness of cine MRI for evaluation of left ventricular volume and diagnosis of heart and great vessel diseases

    International Nuclear Information System (INIS)

    Kondo, Takeshi; Anno, Hirofumi; Uritani, Tomizo

    1990-01-01

    ECG-gated cine mode magnetic resonance (MR) imaging was performed in 20 patients with various heart deseases. Left ventricular volume (LVV) and left ventricular ejection fraction (LVEF) were calculated on MR images obtained in left ventricular vertical and horizontal long axis views. The findings were compared with those obtained from left ventriculography. There was a significant positive correlation between MR imaging and ventriculography for both LVV and LVEF (p<0.001). In Marfan syndrome after surgery for dissecting aneurysm of the aorta, MR imaging was capable of visualizing not only the whole aorta in a single plane but also enlargement of the aortic root. It also depicted asynergy and thinned wall of the infarcted myocardium for myocardial infarction; an enlarged left auricle, the thickened septum, and constricted outflow tract for idiopathic hypertrophic subaortic stenosis; shunt flow for ventricular septum defect; and an enlarged aortic root for aortitis syndrome. Using ventriculography as the standard, cine MR imaging was frequently false positive for the detection of mitral regurgitation. There was, however, good concordance between MR imaging and ventriculography in detecting aortic regurgitation. In addition, MR imaging was equivalent to color Doppler technique for detecting valvular regurgitation. (N.K.)

  16. Mirror-image duplication of the primary axis and heart in Xenopus embryos by the overexpression of Msx-1 gene.

    Science.gov (United States)

    Chen, Y; Solursh, M

    1995-10-01

    The Msx-1 gene (formerly known as Hox-7) is a member of a discrete subclass of homeobox-containing genes. Examination of the expression pattern of Msx-1 in murine and avian embryos suggests that this gene may be involved in the regionalization of the medio-lateral axis during earlier development. We have examined the possible functions of Xenopus Msx-1 during early Xenopus embryonic development by overexpression of the Msx-1 gene. Overexpression of Msx-1 causes a left-right mirror-image duplication of primary axial structures, including notochord, neural tube, somites, suckers, and foregut. The embryonic developing heart is also mirror-image duplicated, including looping directions and polarity. These results indicate that Msx-1 may be involved in the mesoderm formation as well as left-right patterning in the early Xenopus embryonic development.

  17. Heterodyne Angle Deviation Interferometry in Vibration and Bubble Measurements

    OpenAIRE

    Ming-Hung Chiu; Jia-Ze Shen; Jian-Ming Huang

    2016-01-01

    We proposed heterodyne angle deviation interferometry (HADI) for angle deviation measurements. The phase shift of an angular sensor (which can be a metal film or a surface plasmon resonance (SPR) prism) is proportional to the deviation angle of the test beam. The method has been demonstrated in bubble and speaker’s vibration measurements in this paper. In the speaker’s vibration measurement, the voltage from the phase channel of a lock-in amplifier includes the vibration level and frequency. ...

  18. Diagnostic accuracy of electrocardiographic P wave related parameters in the assessment of left atrial size in dogs with degenerative mitral valve disease.

    Science.gov (United States)

    Soto-Bustos, Ángel; Caro-Vadillo, Alicia; Martínez-DE-Merlo, Elena; Alonso-Alegre, Elisa González

    2017-10-07

    The purpose of this research was to compare the accuracy of newly described P wave-related parameters (P wave area, Macruz index and mean electrical axis) with classical P wave-related parameters (voltage and duration of P wave) for the assessment of left atrial (LA) size in dogs with degenerative mitral valve disease. One hundred forty-six dogs (37 healthy control dogs and 109 dogs with degenerative mitral valve disease) were prospectively studied. Two-dimensional echocardiography examinations and a 6-lead ECG were performed prospectively in all dogs. Echocardiography parameters, including determination of the ratios LA diameter/aortic root diameter and LA area/aortic root area, were compared to P wave-related parameters: P wave area, Macruz index, mean electrical axis voltage and duration of P wave. The results showed that P wave-related parameters (classical and newly described) had low sensitivity (range=52.3 to 77%; median=60%) and low to moderate specificity (range=47.2 to 82.5%; median 56.3%) for the prediction of left atrial enlargement. The areas under the curve of P wave-related parameters were moderate to low due to poor sensitivity. In conclusion, newly P wave-related parameters do not increase the diagnostic capacity of ECG as a predictor of left atrial enlargement in dogs with degenerative mitral valve disease.

  19. Associations of electrocardiographic P-wave characteristics with left atrial function, and diffuse left ventricular fibrosis defined by cardiac magnetic resonance: The PRIMERI Study.

    Science.gov (United States)

    Tiffany Win, Theingi; Ambale Venkatesh, Bharath; Volpe, Gustavo J; Mewton, Nathan; Rizzi, Patricia; Sharma, Ravi K; Strauss, David G; Lima, Joao A; Tereshchenko, Larisa G

    2015-01-01

    Abnormal P-terminal force in lead V1 (PTFV1) is associated with an increased risk of heart failure, stroke, atrial fibrillation, and death. Our goal was to explore associations of left ventricular (LV) diffuse fibrosis with left atrial (LA) function and electrocardiographic (ECG) measures of LA electrical activity. Patients without atrial fibrillation (n = 91; mean age 59.5 years; 61.5% men; 65.9% white) with structural heart disease (spatial QRS-T angle ≥105° and/or Selvester QRS score ≥5 on ECG) but LV ejection fraction >35% underwent clinical evaluation, cardiac magnetic resonance, and resting ECG. LA function indices were obtained by multimodality tissue tracking using 2- and 4-chamber long-axis images. T1 mapping and late gadolinium enhancement were used to assess diffuse LV fibrosis and presence of scar. P-prime in V1 amplitude (PPaV1) and duration (PPdV1), averaged P-wave-duration, PR interval, and P-wave axis were automatically measured using 12 SLTM algorithm. PTFV1 was calculated as a product of PPaV1 and PPdV1. In linear regression after adjustment for demographic characteristics, body mass index, maximum LA volume index, presence of scar, and LV mass index, each decile increase in LV interstitial fibrosis was associated with 0.76 mV*ms increase in negative abnormal PTFV1 (95% confidence interval [CI] -1.42 to -0.09; P = .025), 15.3 ms prolongation of PPdV1 (95% CI 6.9 to 23.8; P = .001) and 5.4 ms prolongation of averaged P-duration (95% CI 0.9-10.0; P = .020). LV fibrosis did not affect LA function. PPaV1 and PTFV1 were associated with an increase in LA volumes and decrease in LA emptying fraction and LA reservoir function. LV interstitial fibrosis is associated with abnormal PTFV1, prolonged PPdV1, and P-duration, but does not affect LA function. Copyright © 2015 Heart Rhythm Society. All rights reserved.

  20. Evaluation of single right atrial volume and function with magnetic resonance imaging in children with hypoplastic left heart

    Energy Technology Data Exchange (ETDEWEB)

    Vijarnsorn, Chodchanok [University of Alberta, Faculty of Medicine and Dentistry, Stollery Children' s Hospital, Edmonton, AB (Canada); Mahidol University, Siriraj Hospital, Bangkok (Thailand); Myers, Kimberley; Patton, David J. [Alberta Children' s Hospital, Section of Pediatric Cardiology, Department of Pediatrics, Department of Pediatrics, Calgary, AB (Canada); Noga, Michelle; Crawley, Cinzia; Tham, Edythe [University of Alberta, Faculty of Medicine and Dentistry, Stollery Children' s Hospital, Edmonton, AB (Canada)

    2016-06-15

    Standardized methods to evaluate atrial properties in single ventricles are lacking. To determine the feasibility of quantifying right atrial volumes and function in hypoplastic left heart using MRI. We studied 15 infants with hypoplastic left heart prior to Glenn surgery (mean age 4.2 months [standard deviation 0.3]) who underwent cardiac MRI with evaluation of atrial volumes and emptying fraction using monoplane two-chamber, monoplane four-chamber, and biplane methods, all of which were compared to the atrial short-axial oblique stack method. We compared atrial end-diastolic volume, end-systolic volume and emptying fraction among these methods. We analyzed reproducibility of the methods using Bland-Altman plots. Both four-chamber and biplane methods showed high correlations for atrial end-diastolic volume (r = 0.7 and r = 0.8, respectively; P < 0.01) and end-systolic volume (r = 0.8 and r = 0.9, respectively; P < 0.01) with small mean differences (-0.2 ± 2.9 standard deviation [SD] ml and -0.8 ± 1.6 ml, respectively, for atrial end-diastolic volume and -0.8 ± 1.5 ml and -0.9 ± 0.9 ml, respectively, for atrial end-systolic volume). The short-axial oblique method was the most reproducible, followed by the four-chamber method. MRI assessment of atrial volume and function is feasible in hypoplastic left heart and might provide further insight into single-ventricle mechanics. (orig.)

  1. Right ventricular dysfunction following continuous flow left ventriccular assist device placement in 51 patients: predicators and outcomes

    Directory of Open Access Journals (Sweden)

    Neragi-Miandoab Siyamek

    2012-06-01

    Full Text Available Abstract Background Right ventricular (RV dysfunction following implantation of a left ventricular assist device (LVAD is a serious condition and is associated with increased mortality. Methods The aim of the study is to investigate the significance of pre-existing RV dysfunction, tricuspid valve (TV insufficiency, and the severity of septal deviation following LVAD implantation on RV dysfunction, as well as the outcome and short-term complications in 51 patients from June 2006 to August 2010. Student t test was used to compare the data and estimate the p value. Results Mean age was 55.1 ± 13, with a male to female ratio of 3.25. The 30-day mortality was 13.7% (7/51 patients, and the overall mortality was 23.5% (12/51 patients. Meanwhile, 21 patients (21/51; 41.2% have undergone orthotopic heart transplantation. The mean time of support was 314.5±235 days with a median of 240 days at the time of closing this study. Echocardiographic evaluation of RV function pre- and post-implantation of an LVAD demonstrated septal deviation towards the left ventricle in immediate postoperative phase, which correlated with acute RV dysfunction (p = 0.002. Preoperative RV dysfunction was a significant predictor of postoperative right heart dysfunction following implantation of an LVAD (p = 0.001. Conclusion Preoperative RV dysfunction is a predictor of RV failure in LVAD patients. The adjustment of septal deviation through gradual increase of the LVAD flow can prevent the acute RV dysfunction following LVAD placement.

  2. The effect of postoperative medical treatment on left ventricular mass regression after aortic valve replacement.

    Science.gov (United States)

    Helder, Meghana R K; Ugur, Murat; Bavaria, Joseph E; Kshettry, Vibhu R; Groh, Mark A; Petracek, Michael R; Jones, Kent W; Suri, Rakesh M; Schaff, Hartzell V

    2015-03-01

    The study objective was to analyze factors associated with left ventricular mass regression in patients undergoing aortic valve replacement with a newer bioprosthesis, the Trifecta valve pericardial bioprosthesis (St Jude Medical Inc, St Paul, Minn). A total of 444 patients underwent aortic valve replacement with the Trifecta bioprosthesis from 2007 to 2009 at 6 US institutions. The clinical and echocardiographic data of 200 of these patients who had left ventricular hypertrophy and follow-up studies 1 year postoperatively were reviewed and compared to analyze factors affecting left ventricular mass regression. Mean (standard deviation) age of the 200 study patients was 73 (9) years, 66% were men, and 92% had pure or predominant aortic valve stenosis. Complete left ventricular mass regression was observed in 102 patients (51%) by 1 year postoperatively. In univariate analysis, male sex, implantation of larger valves, larger left ventricular end-diastolic volume, and beta-blocker or calcium-channel blocker treatment at dismissal were significantly associated with complete mass regression. In the multivariate model, odds ratios (95% confidence intervals) indicated that male sex (3.38 [1.39-8.26]) and beta-blocker or calcium-channel blocker treatment at dismissal (3.41 [1.40-8.34]) were associated with increased probability of complete left ventricular mass regression. Patients with higher preoperative systolic blood pressure were less likely to have complete left ventricular mass regression (0.98 [0.97-0.99]). Among patients with left ventricular hypertrophy, postoperative treatment with beta-blockers or calcium-channel blockers may enhance mass regression. This highlights the need for close medical follow-up after operation. Labeled valve size was not predictive of left ventricular mass regression. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  3. [The crooked nose: correction of dorsal and caudal septal deviations].

    Science.gov (United States)

    Foda, H M T

    2010-09-01

    The deviated nose represents a complex cosmetic and functional problem. Septal surgery plays a central role in the successful management of the externally deviated nose. This study included 800 patients seeking rhinoplasty to correct external nasal deviations; 71% of these suffered from variable degrees of nasal obstruction. Septal surgery was necessary in 736 (92%) patients, not only to improve breathing, but also to achieve a straight, symmetric external nose. A graduated surgical approach was adopted to allow correction of the dorsal and caudal deviations of the nasal septum without weakening its structural support to the nasal dorsum or nasal tip. The approach depended on full mobilization of deviated cartilage, followed by straightening of the cartilage and its fixation in the corrected position by using bony splinting grafts through an external rhinoplasty approach.

  4. Vertical axis wind turbine airfoil

    Science.gov (United States)

    Krivcov, Vladimir; Krivospitski, Vladimir; Maksimov, Vasili; Halstead, Richard; Grahov, Jurij Vasiljevich

    2012-12-18

    A vertical axis wind turbine airfoil is described. The wind turbine airfoil can include a leading edge, a trailing edge, an upper curved surface, a lower curved surface, and a centerline running between the upper surface and the lower surface and from the leading edge to the trailing edge. The airfoil can be configured so that the distance between the centerline and the upper surface is the same as the distance between the centerline and the lower surface at all points along the length of the airfoil. A plurality of such airfoils can be included in a vertical axis wind turbine. These airfoils can be vertically disposed and can rotate about a vertical axis.

  5. Comparison of exercise radionuclide angiography with thallium SPECT imaging for detection of significant narrowing of the left circumflex coronary artery

    International Nuclear Information System (INIS)

    Dilsizian, V.; Perrone-Filardi, P.; Cannon, R.O. III; Freedman, N.M.; Bacharach, S.L.; Bonow, R.O.

    1991-01-01

    Although quantitation of exercise thallium tomograms has enhanced the noninvasive diagnosis and localization of coronary artery disease, the detection of stenosis of the left circumflex coronary artery remains suboptimal. Because posterolateral regional wall motion during exercise is well assessed by radionuclide angiography, this study determined whether regional dysfunction of the posterolateral wall during exercise radionuclide angiography is more sensitive in identifying left circumflex disease than thallium perfusion abnormalities assessed by single-photon emission computed tomography (SPECT). One hundred ten consecutive patients with CAD were studied, of whom 70 had a significant stenosis of the left circumflex coronary artery or a major obtuse marginal branch. Both regional function and segmental thallium activity of the posterolateral wall were assessed using visual and quantitative analysis. Left ventricular regional function was assessed objectively by dividing the left ventricular region of interest into 20 sectors; the 8 sectors corresponding to the posterolateral free wall were used to assess function in the left circumflex artery distribution. Similarly, using circumferential profile analysis of short-axis thallium tomograms, left ventricular myocardial activity was subdivided into 64 sectors; the 16 sectors corresponding to the posterolateral region were used to assess thallium perfusion abnormalities in the left circumflex artery territory. Qualitative posterolateral wall motion analysis detected 76% of patients with left circumflex coronary artery stenosis, with a specificity of 83%, compared with only 44% by qualitative thallium tomography (p less than 0.001) and a specificity of 92%

  6. Distortion definition and correction in off-axis systems

    Science.gov (United States)

    Da Deppo, Vania; Simioni, Emanuele; Naletto, Giampiero; Cremonese, Gabriele

    2015-09-01

    Off-axis optical configurations are becoming more and more used in a variety of applications, in particular they are the most preferred solution for cameras devoted to Solar System planets and small bodies (i.e. asteroids and comets) study. Off-axis designs, being devoid of central obstruction, are able to guarantee better PSF and MTF performance, and thus higher contrast imaging capabilities with respect to classical on-axis designs. In particular they are suitable for observing extended targets with intrinsic low contrast features, or scenes where a high dynamical signal range is present. Classical distortion theory is able to well describe the performance of the on-axis systems, but it has to be adapted for the off-axis case. A proper way to deal with off-axis distortion definition is thus needed together with dedicated techniques to accurately measure and hence remove the distortion effects present in the acquired images. In this paper, a review of the distortion definition for off-axis systems will be given. In particular the method adopted by the authors to deal with the distortion related issues (definition, measure, removal) in some off-axis instruments will be described in detail.

  7. Consistent left-right asymmetry cannot be established by late organizers in Xenopus unless the late organizer is a conjoined twin.

    Science.gov (United States)

    Vandenberg, Laura N; Levin, Michael

    2010-04-01

    How embryos consistently orient asymmetries of the left-right (LR) axis is an intriguing question, as no macroscopic environmental cues reliably distinguish left from right. Especially unclear are the events coordinating LR patterning with the establishment of the dorsoventral (DV) axes and midline determination in early embryos. In frog embryos, consistent physiological and molecular asymmetries manifest by the second cell cleavage; however, models based on extracellular fluid flow at the node predict correct de novo asymmetry orientation during neurulation. We addressed these issues in Xenopus embryos by manipulating the timing and location of dorsal organizer induction: the primary dorsal organizer was ablated by UV irradiation, and a new organizer was induced at various locations, either early, by mechanical rotation, or late, by injection of lithium chloride (at 32 cells) or of the transcription factor XSiamois (which functions after mid-blastula transition). These embryos were then analyzed for the position of three asymmetric organs. Whereas organizers rescued before cleavage properly oriented the LR axis 90% of the time, organizers induced in any position at any time after the 32-cell stage exhibited randomized laterality. Late organizers were unable to correctly orient the LR axis even when placed back in their endogenous location. Strikingly, conjoined twins produced by late induction of ectopic organizers did have normal asymmetry. These data reveal that although correct LR orientation must occur no later than early cleavage stages in singleton embryos, a novel instructive influence from an early organizer can impose normal asymmetry upon late organizers in the same cell field.

  8. Complexity analysis based on generalized deviation for financial markets

    Science.gov (United States)

    Li, Chao; Shang, Pengjian

    2018-03-01

    In this paper, a new modified method is proposed as a measure to investigate the correlation between past price and future volatility for financial time series, known as the complexity analysis based on generalized deviation. In comparison with the former retarded volatility model, the new approach is both simple and computationally efficient. The method based on the generalized deviation function presents us an exhaustive way showing the quantization of the financial market rules. Robustness of this method is verified by numerical experiments with both artificial and financial time series. Results show that the generalized deviation complexity analysis method not only identifies the volatility of financial time series, but provides a comprehensive way distinguishing the different characteristics between stock indices and individual stocks. Exponential functions can be used to successfully fit the volatility curves and quantify the changes of complexity for stock market data. Then we study the influence for negative domain of deviation coefficient and differences during the volatile periods and calm periods. after the data analysis of the experimental model, we found that the generalized deviation model has definite advantages in exploring the relationship between the historical returns and future volatility.

  9. Actuator assembly including a single axis of rotation locking member

    Science.gov (United States)

    Quitmeyer, James N.; Benson, Dwayne M.; Geck, Kellan P.

    2009-12-08

    An actuator assembly including an actuator housing assembly and a single axis of rotation locking member fixedly attached to a portion of the actuator housing assembly and an external mounting structure. The single axis of rotation locking member restricting rotational movement of the actuator housing assembly about at least one axis. The single axis of rotation locking member is coupled at a first end to the actuator housing assembly about a Y axis and at a 90.degree. angle to an X and Z axis providing rotation of the actuator housing assembly about the Y axis. The single axis of rotation locking member is coupled at a second end to a mounting structure, and more particularly a mounting pin, about an X axis and at a 90.degree. angle to a Y and Z axis providing rotation of the actuator housing assembly about the X axis. The actuator assembly is thereby restricted from rotation about the Z axis.

  10. Normal nonuniformity of left ventricular contraction. Assessment by cine MR imaging with presaturation myocardial tagging

    International Nuclear Information System (INIS)

    Naito, H.; Arisawa, J.; Harada, K.; Yamagami, H.; Kozuka, T.; Tamura, S.

    1996-01-01

    Purpose: To identify the normal performance of left ventricular (LV) regional contraction using cine MR imaging with presaturation myocardial tagging. Material and Methods: Sixteen normal volunteers were examined on a 1.5 T MR system with tagging cine sequences. Tags were applied at end-diastole as 2 parallel black lines on short-axis and 4-chamber sections, and the fractional shortenings were calculated at 7 LV locations. Results: The following results were obtained with significance: A transmural gradient of contractility in the short-axis section; prolonged late-systolic endocardial shortening and epicardial early termination in the free wall; initial delay of shortening in the anterior wall; apical predominance of contractility; predominance of circumferential shortening in the free wall and of meridional shortening in the septum. These findings could be associated with myocardial fiber architecture, presumed wall stress and temporal asynergy of excitation. Conclusion: Cine MR imaging with myocardial tagging proved to be useful in assessing the nonuniformity of LV contraction. (orig.)

  11. Output energy of a photovoltaic module mounted on a single-axis tracking system

    International Nuclear Information System (INIS)

    Chang, Tian Pau

    2009-01-01

    In this study, the electric energy from a photovoltaic module was calculated theoretically at different azimuths and tilt angles in Taiwan. The gain of the module mounted on a single-axis tracking panel relative to a traditional fixed panel was analyzed. To simulate different operation environments, both types of radiation will be considered in addition to observed radiation, i.e. the extraterrestrial radiation and the global radiation predicted by an empirical model. The results show that the optimal tilt angle obtained from the observed data is flatter than those from other two radiation types and becomes flatter while the panel deviates from due south. The yearly gains obtained from the extraterrestrial, predicted and observed radiations are 51.4%, 28.5% and 18.7%, respectively, if a single-axis tracked panel is installed with the yearly optimal tilt angle; the similar gains are 45.3%, 25.9% and 17.5%, respectively, while the panel is adjusted to its monthly optimal angle each month. The amount of yearly energy in due west (or east) is less than its maximum in due south by about 11%, 10% and 5% for the extraterrestrial, predicted and observed radiation respectively. The yearly conversion efficiency of a fixed module is 10.2%, 9.2% and 8.3% for the extraterrestrial, predicted and observed radiation, respectively.

  12. An elusive persistent left superior vena cava draining into left atrium

    NARCIS (Netherlands)

    A. Soward; F.J. ten Cate (Folkert); P.M. Fioretti (Paolo); P.W.J.C. Serruys (Patrick); J.R.T.C. Roelandt (Jos)

    1986-01-01

    textabstractA case report of a persistent left superior vena cava draining into left atrium with a fibromuscular left ventricular outflow tract obstruction and a small atrial septal defect. The anomalous vessel escaped detection during two right and left heart catheterizations from the right arm and

  13. Deviation equation in spaces with affine connection. Pts. 3 and 4

    International Nuclear Information System (INIS)

    Iliev, B.Z.

    1987-01-01

    The concept of a parallel transport is used to define a class of displacement vectors in spaces with affine connection. The nonlocal deviation equation in such spaces is introduced using a definition of the deviation vector based on the displacement vector. It turns out to be a special of the generalized deviation equation, but having an appropriate physical interpretation. The equation of geodesic deviation is presented as an example

  14. Is the basic trunk control recovery different between stroke patients with right and left hemiparesis?

    Science.gov (United States)

    Pappalardo, A; Ciancio, M R; Patti, F

    2014-01-01

    Basic trunk movement control is often impaired after stroke and its recovery is a "miliary stone" in rehabilitation. In this prospective, observational, parallel-group study, we investigated whether there are differences in terms of post-stroke recovery of basic trunk control between patients with left or with right hemiparesis. We recruited 94 patients with loss of postural trunk control due to stroke. Patients were divided into Group A (48 patients with left hemiparesis) and Group B (46 patients with right hemiparesis). We administered the Trunk Control Test (TCT) and the 13 motor items included on the Functional Independence Measure. Evaluation was performed at admission (To) and discharge (T1). TCT increased respectively from 46.7 ± 23.3 to 62.6 ± 19.5 (mean ± standard deviation-SD, p hemiparesis could affect the degree of recovery of basic trunk control after stroke. Patients with right hemiparesis benefit more than those with left hemiparesis. Improvement of basic trunk control was not responsible for an advantage on functional independence.

  15. Effect of Relative Marker Movement on the Calculation of the Foot Torsion Axis Using a Combined Cardan Angle and Helical Axis Approach

    Science.gov (United States)

    Graf, Eveline S.; Wright, Ian C.; Stefanyshyn, Darren J.

    2012-01-01

    The two main movements occurring between the forefoot and rearfoot segment of a human foot are flexion at the metatarsophalangeal joints and torsion in the midfoot. The location of the torsion axis within the foot is currently unknown. The purpose of this study was to develop a method based on Cardan angles and the finite helical axis approach to calculate the torsion axis without the effect of flexion. As the finite helical axis method is susceptible to error due to noise with small helical rotations, a minimal amount of rotation was defined in order to accurately determine the torsion axis location. Using simulation, the location of the axis based on data containing noise was compared to the axis location of data without noise with a one-sample t-test and Fisher's combined probability score. When using only data with helical rotation of seven degrees or more, the location of the torsion axis based on the data with noise was within 0.2 mm of the reference location. Therefore, the proposed method allowed an accurate calculation of the foot torsion axis location. PMID:22666303

  16. Effect of Relative Marker Movement on the Calculation of the Foot Torsion Axis Using a Combined Cardan Angle and Helical Axis Approach

    Directory of Open Access Journals (Sweden)

    Eveline S. Graf

    2012-01-01

    Full Text Available The two main movements occurring between the forefoot and rearfoot segment of a human foot are flexion at the metatarsophalangeal joints and torsion in the midfoot. The location of the torsion axis within the foot is currently unknown. The purpose of this study was to develop a method based on Cardan angles and the finite helical axis approach to calculate the torsion axis without the effect of flexion. As the finite helical axis method is susceptible to error due to noise with small helical rotations, a minimal amount of rotation was defined in order to accurately determine the torsion axis location. Using simulation, the location of the axis based on data containing noise was compared to the axis location of data without noise with a one-sample t-test and Fisher's combined probability score. When using only data with helical rotation of seven degrees or more, the location of the torsion axis based on the data with noise was within 0.2 mm of the reference location. Therefore, the proposed method allowed an accurate calculation of the foot torsion axis location.

  17. Can the recovery of lower limb fractures be achieved by use of 3D printing mirror model?

    Science.gov (United States)

    Zhang, Wenxi; Ji, Yueping; Wang, Xinming; Liu, Jie; Li, Dong

    2017-11-01

    The mirror imaging 3D printing model can be used a as a reference for anatomical reduction in unilateral lower limb fractures. However, the premise of using mirror technology is that the bilateral lower limb bones are similar enough. Because one side had a fracture, it was impossible to compare this directly to the other side. Usually, surgeons think that the bilateral bones are symmetrical and use mirror technology without judging their symmetry. In patients with a unilateral lower limb bone fracture, we measured the long axis and short axis of the three selected transverse sections of the bilateral long bone for comparison to judge the symmetry of the bilateral long bones on CT images. Then, we printed a life-size normal mirror image of the long bone that is similar to the affected side. The model was used as a reference for the anatomical reduction of fractures and preoperative practice. Seventy-eight patients with lower limb bone fracture were included in this study. 24 groups of data were generated according to the same level and same axis. There were significant differences between the short axis of the left and right femoral condyle 5cm from the intercondylar keel (p=0.011), and the short axis of the distal tibia 15cm from the ankle dome (p=0.026). There was no significant difference between the left and right sides in the other 22 groups. Of all of the patients in our research, 3 patients decided to forego the surgical treatment and the operation was performed on the model instead, and the lengths of 2 patients showed deviation in actual operations, preventing anatomical reduction. The remaining 73 patients used the pre-bended plates and screws from preoperative practice in the actual operations, and postoperative X-ray examinations showed that the length of the deviation was within the permissible range. The "Comparison of long axis and short axis of three equidistant transverse sections" method makes it easy to judge the symmetry of the bilateral long

  18. Influence of asymmetrical drawing radius deviation in micro deep drawing

    Science.gov (United States)

    Heinrich, L.; Kobayashi, H.; Shimizu, T.; Yang, M.; Vollertsen, F.

    2017-09-01

    Nowadays, an increasing demand for small metal parts in electronic and automotive industries can be observed. Deep drawing is a well-suited technology for the production of such parts due to its excellent qualities for mass production. However, the downscaling of the forming process leads to new challenges in tooling and process design, such as high relative deviation of tool geometry or blank displacement compared to the macro scale. FEM simulation has been a widely-used tool to investigate the influence of symmetrical process deviations as for instance a global variance of the drawing radius. This study shows a different approach that allows to determine the impact of asymmetrical process deviations on micro deep drawing. In this particular case the impact of an asymmetrical drawing radius deviation and blank displacement on cup geometry deviation was investigated for different drawing ratios by experiments and FEM simulation. It was found that both variations result in an increasing cup height deviation. Nevertheless, with increasing drawing ratio a constant drawing radius deviation has an increasing impact, while blank displacement results in a decreasing offset of the cups geometry. This is explained by different mechanisms that result in an uneven cup geometry. While blank displacement leads to material surplus on one side of the cup, an unsymmetrical radius deviation on the other hand generates uneven stretching of the cups wall. This is intensified for higher drawing ratios. It can be concluded that the effect of uneven radius geometry proves to be of major importance for the production of accurately shaped micro cups and cannot be compensated by intentional blank displacement.

  19. Usefulness of tomographic phase image in ventricular conduction abnormalities

    International Nuclear Information System (INIS)

    Sakurai, Mitsuru; Watanabe, Yoshihiko; Kondo, Takeshi

    1985-01-01

    In order to evaluate three-dimensional phase changes in ventricular conduction abnormalities, tomographic phase images were constructed in 7 normal subjects, 12 patients with ventricular pacing, 21 patients with bundle branch block and 12 patients with Wolff-Parkinson-White syndrome. Eight to 12 slices of the short-axis ventricular tomographic phase image (TPI) were derived using a 7-pinhole collimator, and compared with planar phase images (PPIs) in left anterior oblique (LAO) and right anterior oblique (RAO) projections. TPIs were excellent for observing biventricular phase changes in the long-axis direction. In 6 cases of complete right bundle branch block with left axis deviation (beyond -30 0 ), the phase delay in the left ventricular anterior wall was recognized in 5 cases by TPI, although it was difficult to be detected by PPIs. The site of the pacing electrode was identified by TPI in 11 out of 12 cases, compared to 8 cases by PPIs in LAO and RAO projections. The site of the accessory pathway in Wolff-Parkinson-White syndrome was detected in the basal slice of TPIs in 10 out of 12 cases, compared to 8 cases by PPI in the LAO projection. Therefore, it is obvious that TPIs offer more valid information than PPIs. In conclusion, TPI is useful for investigation of ventricular conduction abnormalities. (author)

  20. Limiting values of large deviation probabilities of quadratic statistics

    NARCIS (Netherlands)

    Jeurnink, Gerardus A.M.; Kallenberg, W.C.M.

    1990-01-01

    Application of exact Bahadur efficiencies in testing theory or exact inaccuracy rates in estimation theory needs evaluation of large deviation probabilities. Because of the complexity of the expressions, frequently a local limit of the nonlocal measure is considered. Local limits of large deviation

  1. Refraction in Terms of the Deviation of the Light.

    Science.gov (United States)

    Goldberg, Fred M.

    1985-01-01

    Discusses refraction in terms of the deviation of light. Points out that in physics courses where very little mathematics is used, it might be more suitable to describe refraction entirely in terms of the deviation, rather than by introducing Snell's law. (DH)

  2. Concept of a Programmable Fixture for 3-Axis CNC

    Directory of Open Access Journals (Sweden)

    Ahmad Dalloul

    2017-09-01

    Full Text Available CNC machine is the one of the major reasons for industrial advancement in recent decades for its ability of producing accurate parts. The most commen CNC machines are of 3-axis and adopted widely in the industrial sector. However, for producing more complicated parts 5-axis CNC machines are required. Although the introduction of the 5-axis machine came after the 3-axis CNC machine has established itself and many manufacturers did not make the move toward the newer model and its high pricing compared to the 3-axis model did not help either. In this time the development of a fixture or a platform to help transfer the 3-axis to a 5-axis to some degree. This paper discusses the concept of a programmable fixture that gives 3-axis CNC machine the freedom to act in similar manner as the 5-axis. The paper describes the mechanism with some initial results of the testing. Result showed that the platform moves in translation manner with an average error of 5.58 % and 7.303% average error for rotation movement.

  3. HEART ELECTRICAL AXIS Α ANGLE VALUES DISTRIBUTION IN PATIENTS, UNDERGOING PERMANENT PACEMAKER IMPLANTATION

    Directory of Open Access Journals (Sweden)

    O. S. Voronenko

    2016-06-01

    Full Text Available 52 patients (24 male and 28 female aged 71 ± 8 years, underwent permanent pacemaker implantation were included in the study. Analysis of heart electrical axis (HEA α angle values distribution was carried out in three dimensions in patience before and after pacemaker (PM implantation. The data processed in Microsoft Excel with calculation of the average and it’s standard deviation. Significance of differences in data before and after PM implantation was assessed using Friedman ANOVA test and Kendall concordance coefficient. It was found, that α angle values distribution in patients with implanted PM is transformed from a unimodal to bimodal on the permanent cardiac pacing background. It’s assumed, that α angle changes resulting due to right ventricular electrode positioning options during PM implantation. Clarification of the nature of this change requires a special study.

  4. Mean-deviation analysis in the theory of choice.

    Science.gov (United States)

    Grechuk, Bogdan; Molyboha, Anton; Zabarankin, Michael

    2012-08-01

    Mean-deviation analysis, along with the existing theories of coherent risk measures and dual utility, is examined in the context of the theory of choice under uncertainty, which studies rational preference relations for random outcomes based on different sets of axioms such as transitivity, monotonicity, continuity, etc. An axiomatic foundation of the theory of coherent risk measures is obtained as a relaxation of the axioms of the dual utility theory, and a further relaxation of the axioms are shown to lead to the mean-deviation analysis. Paradoxes arising from the sets of axioms corresponding to these theories and their possible resolutions are discussed, and application of the mean-deviation analysis to optimal risk sharing and portfolio selection in the context of rational choice is considered. © 2012 Society for Risk Analysis.

  5. Illusory shadow person causing paradoxical gaze deviations during temporal lobe seizures

    NARCIS (Netherlands)

    Zijlmans, M.; van Eijsden, P.; Ferrier, C. H.; Kho, K. H.; van Rijen, P. C.; Leijten, F. S. S.

    Generally, activation of the frontal eye field during seizures can cause versive (forced) gaze deviation, while non-versive head deviation is hypothesised to result from ictal neglect after inactivation of the ipsilateral temporoparietal area. Almost all non-versive head deviations occurring during

  6. Deviations from Newton's law in supersymmetric large extra dimensions

    International Nuclear Information System (INIS)

    Callin, P.; Burgess, C.P.

    2006-01-01

    Deviations from Newton's inverse-squared law at the micron length scale are smoking-gun signals for models containing supersymmetric large extra dimensions (SLEDs), which have been proposed as approaches for resolving the cosmological constant problem. Just like their non-supersymmetric counterparts, SLED models predict gravity to deviate from the inverse-square law because of the advent of new dimensions at sub-millimeter scales. However SLED models differ from their non-supersymmetric counterparts in three important ways: (i) the size of the extra dimensions is fixed by the observed value of the dark energy density, making it impossible to shorten the range over which new deviations from Newton's law must be seen; (ii) supersymmetry predicts there to be more fields in the extra dimensions than just gravity, implying different types of couplings to matter and the possibility of repulsive as well as attractive interactions; and (iii) the same mechanism which is purported to keep the cosmological constant naturally small also keeps the extra-dimensional moduli effectively massless, leading to deviations from general relativity in the far infrared of the scalar-tensor form. We here explore the deviations from Newton's law which are predicted over micron distances, and show the ways in which they differ and resemble those in the non-supersymmetric case

  7. Performance of Phonatory Deviation Diagrams in Synthesized Voice Analysis.

    Science.gov (United States)

    Lopes, Leonardo Wanderley; da Silva, Karoline Evangelista; da Silva Evangelista, Deyverson; Almeida, Anna Alice; Silva, Priscila Oliveira Costa; Lucero, Jorge; Behlau, Mara

    2018-05-02

    To analyze the performance of a phonatory deviation diagram (PDD) in discriminating the presence and severity of voice deviation and the predominant voice quality of synthesized voices. A speech-language pathologist performed the auditory-perceptual analysis of the synthesized voice (n = 871). The PDD distribution of voice signals was analyzed according to area, quadrant, shape, and density. Differences in signal distribution regarding the PDD area and quadrant were detected when differentiating the signals with and without voice deviation and with different predominant voice quality. Differences in signal distribution were found in all PDD parameters as a function of the severity of voice disorder. The PDD area and quadrant can differentiate normal voices from deviant synthesized voices. There are differences in signal distribution in PDD area and quadrant as a function of the severity of voice disorder and the predominant voice quality. However, the PDD area and quadrant do not differentiate the signals as a function of severity of voice disorder and differentiated only the breathy and rough voices from the normal and strained voices. PDD density is able to differentiate only signals with moderate and severe deviation. PDD shape shows differences between signals with different severities of voice deviation. © 2018 S. Karger AG, Basel.

  8. Generation of deviation parameters for amino acid singlets, doublets ...

    Indian Academy of Sciences (India)

    We present a new method, secondary structure prediction by deviation parameter (SSPDP) for predicting the secondary structure of proteins from amino acid sequence. Deviation parameters (DP) for amino acid singlets, doublets and triplets were computed with respect to secondary structural elements of proteins based on ...

  9. Accuracy of ECG indices for diagnosis of left ventricular hypertrophy in people >65 years: results from the ActiFE study.

    Science.gov (United States)

    Laszlo, Roman; Kunz, Katia; Dallmeier, Dhayana; Klenk, Jochen; Denkinger, Michael; Koenig, Wolfgang; Rothenbacher, Dietrich; Steinacker, Juergen Michael

    2017-10-01

    The detection of left ventricular hypertrophy (LVH) is still a common objective of electrocardiography (ECG) in clinical practice. The aim of our study was to evaluate the accuracy of LVH ECG indices in people older than 65 recruited from a population-based cohort (ActiFE-Ulm study). In 432 subjects (mean age 76.2 ± 5.5 years, 51% male), left ventricular mass was echocardiographically determined (Devereux formula) and indexed (LVMI) to body surface area. Several LVH ECG indices (Lewis voltage, Gubner-Ungerleider voltage, Sokolow-Lyon voltage/product, Cornell voltage/product) were calculated with the help of resting ECG data and compared with the echocardiographic assessment. Despite echocardiographic signs of LVH [LVMI > 115 (♂) or >95 g/m 2 (♀)] in 47.5% of all subjects, diagnostic performance of all ECG indices was generally low. Magnitude of all LVH-indices was mainly predicted by frontal QRS axis in multivariate linear regression analysis. In comparison with the literature data from younger subjects, average frontal QRS axis turned counterclockwise. Most probably, age-related counterclockwise turn of frontal QRS axis is mainly explanatory for the decreased magnitude of LVH ECG indices and consecutive worse diagnostic performance of these indices in the elderly. ECG indices for detection of LVH have insufficient predictive values in geriatric subjects and should therefore not be used clinically for this purpose. Nevertheless, due to its established relevancy in cardiac risk stratification in this age group, usage of some established ECG indices might keep its significance even in the age of modern cardiac imaging.

  10. VAR Portfolio Optimal: Perbandingan Antara Metode Markowitz dan Mean Absolute Deviation

    Directory of Open Access Journals (Sweden)

    R. Agus Sartono

    2009-05-01

    Full Text Available Portfolio selection method which have been introduced by Harry Markowitz (1952 used variance or deviation standard as a measure of risk. Kanno and Yamazaki (1991 introduced another method and used mean absolute deviation as a measure of risk instead of variance. The Value-at Risk (VaR is a relatively new method to capitalized risk that been used by financial institutions. The aim of this research is compare between mean variance and mean absolute deviation of two portfolios. Next, we attempt to assess the VaR of two portfolios using delta normal method and historical simulation. We use the secondary data from the Jakarta Stock Exchange – LQ45 during 2003. We find that there is a weak-positive correlation between deviation standard and return in both portfolios. The VaR nolmal delta based on mean absolute deviation method eventually is higher than the VaR normal delta based on mean variance method. However, based on the historical simulation the VaR of two methods is statistically insignificant. Thus, the deviation standard is sufficient measures of portfolio risk.Keywords: optimalisasi portofolio, mean-variance, mean-absolute deviation, value-at-risk, metode delta normal, metode simulasi historis

  11. Importance sampling large deviations in nonequilibrium steady states. I

    Science.gov (United States)

    Ray, Ushnish; Chan, Garnet Kin-Lic; Limmer, David T.

    2018-03-01

    Large deviation functions contain information on the stability and response of systems driven into nonequilibrium steady states and in such a way are similar to free energies for systems at equilibrium. As with equilibrium free energies, evaluating large deviation functions numerically for all but the simplest systems is difficult because by construction they depend on exponentially rare events. In this first paper of a series, we evaluate different trajectory-based sampling methods capable of computing large deviation functions of time integrated observables within nonequilibrium steady states. We illustrate some convergence criteria and best practices using a number of different models, including a biased Brownian walker, a driven lattice gas, and a model of self-assembly. We show how two popular methods for sampling trajectory ensembles, transition path sampling and diffusion Monte Carlo, suffer from exponentially diverging correlations in trajectory space as a function of the bias parameter when estimating large deviation functions. Improving the efficiencies of these algorithms requires introducing guiding functions for the trajectories.

  12. Importance sampling large deviations in nonequilibrium steady states. I.

    Science.gov (United States)

    Ray, Ushnish; Chan, Garnet Kin-Lic; Limmer, David T

    2018-03-28

    Large deviation functions contain information on the stability and response of systems driven into nonequilibrium steady states and in such a way are similar to free energies for systems at equilibrium. As with equilibrium free energies, evaluating large deviation functions numerically for all but the simplest systems is difficult because by construction they depend on exponentially rare events. In this first paper of a series, we evaluate different trajectory-based sampling methods capable of computing large deviation functions of time integrated observables within nonequilibrium steady states. We illustrate some convergence criteria and best practices using a number of different models, including a biased Brownian walker, a driven lattice gas, and a model of self-assembly. We show how two popular methods for sampling trajectory ensembles, transition path sampling and diffusion Monte Carlo, suffer from exponentially diverging correlations in trajectory space as a function of the bias parameter when estimating large deviation functions. Improving the efficiencies of these algorithms requires introducing guiding functions for the trajectories.

  13. Standard Deviation for Small Samples

    Science.gov (United States)

    Joarder, Anwar H.; Latif, Raja M.

    2006-01-01

    Neater representations for variance are given for small sample sizes, especially for 3 and 4. With these representations, variance can be calculated without a calculator if sample sizes are small and observations are integers, and an upper bound for the standard deviation is immediate. Accessible proofs of lower and upper bounds are presented for…

  14. Accuracy of Outcome Anticipation, But Not Gaze Behavior, Differs Against Left- and Right-Handed Penalties in Team-Handball Goalkeeping.

    Science.gov (United States)

    Loffing, Florian; Sölter, Florian; Hagemann, Norbert; Strauss, Bernd

    2015-01-01

    Low perceptual familiarity with relatively rarer left-handed as opposed to more common right-handed individuals may result in athletes' poorer ability to anticipate the former's action intentions. Part of such left-right asymmetry in visual anticipation could be due to an inefficient gaze strategy during confrontation with left-handed individuals. To exemplify, observers may not mirror their gaze when viewing left- vs. right-handed actions but preferentially fixate on an opponent's right body side, irrespective of an opponent's handedness, owing to the predominant exposure to right-handed actions. So far empirical verification of such assumption, however, is lacking. Here we report on an experiment where team-handball goalkeepers' and non-goalkeepers' gaze behavior was recorded while they predicted throw direction of left- and right-handed 7-m penalties shown as videos on a computer monitor. As expected, goalkeepers were considerably more accurate than non-goalkeepers and prediction was better against right- than left-handed penalties. However, there was no indication of differences in gaze measures (i.e., number of fixations, overall and final fixation duration, time-course of horizontal or vertical fixation deviation) as a function of skill group or the penalty-takers' handedness. Findings suggest that inferior anticipation of left-handed compared to right-handed individuals' action intentions may not be associated with misalignment in gaze behavior. Rather, albeit looking similarly, accuracy differences could be due to observers' differential ability of picking up and interpreting the visual information provided by left- vs. right-handed movements.

  15. CT Assessment of the axial deviation of the femoral and tibial prosthetic components in total knee arthroplasty

    International Nuclear Information System (INIS)

    Rimondi, E.; Molinari, M.; Moio, A.; Busacca, M.; Trentani, F.; Trentani, P.; Tigani, D.; Nigrosoli, M.

    2000-01-01

    CT assessment of the axial deviation of the femoral and tibial prosthetic components in total knee arthroplasty. From January to July 1999, 17 patients, 10 males and 7 females, mean age 66 years (standard deviation plus or minus 4) were examined after total knee arthroplasty. Exclusion criteriawere prosthesis loosening and severe (equal or superior to 7'' varus o valgus deviation. All patients were examined with knee radiography in the standing position completed by axial projection of patella and by CT scanning. It was used a modification of Berger technique and carried out comparative CT scans extended lower limbs and acquisitions perpendicular to the mechanical axis of the knee, from the femoral supracondylar region down to the plane crossing the distal end of the tibial prosthetic component. Reference lines were then drawn electronically on given scanning planes to reckon the axial deviation of the femoral and tibial prosthetic components. Six patients, one female and 5 males with normal rotational values of femoral and tibial prosthetic components presented no clinical symptoms. Eight patients, 4 females and 4 males, with abnormal values presented the following clinical symptoms: medial impingement, (incomplete) dislocation patella, and lateral instability. One female patient with a normal rotational value of femoral prosthetic component and an altered value of tibial prosthetic component presented medial impingement. Finally two patients, one female and one male, were absolutely asymptomatic although the rotational values of the two prosthetic components were beyond the normal range. Total knee arthroplasty is presently a standard treatment for many conditions involving this joint. There are several possible postoperative complications, namely fractures, dislocations (a)septic losening and femoropatellar instability. The latter condition is the most frequent complication among implant failures and is caused by bad orientation of the femoral and tibial

  16. Serotonin has early, cilia-independent roles in Xenopus left-right patterning

    Directory of Open Access Journals (Sweden)

    Laura N. Vandenberg

    2013-01-01

    Consistent left-right (LR patterning of the heart and viscera is a crucial part of normal embryogenesis. Because errors of laterality form a common class of birth defects, it is important to understand the molecular mechanisms and stage at which LR asymmetry is initiated. Frog embryos are a system uniquely suited to analysis of the mechanisms involved in orientation of the LR axis because of the many genetic and pharmacological tools available for use and the fate-map and accessibility of early blastomeres. Two major models exist for the origin of LR asymmetry and both implicate pre-nervous serotonergic signaling. In the first, the charged serotonin molecule is instructive for LR patterning; it is redistributed asymmetrically along the LR axis and signals intracellularly on the right side at cleavage stages. A second model suggests that serotonin is a permissive factor required to specify the dorsal region of the embryo containing chiral cilia that generate asymmetric fluid flow during neurulation, a much later process. We performed theory-neutral experiments designed to distinguish between these models. The results uniformly support a role for serotonin in the cleavage-stage embryo, long before the appearance of cilia, in ventral right blastomeres that do not contribute to the ciliated organ.

  17. Linear versus non-linear measures of temporal variability in finger tapping and their relation to performance on open- versus closed-loop motor tasks: comparing standard deviations to Lyapunov exponents.

    Science.gov (United States)

    Christman, Stephen D; Weaver, Ryan

    2008-05-01

    The nature of temporal variability during speeded finger tapping was examined using linear (standard deviation) and non-linear (Lyapunov exponent) measures. Experiment 1 found that right hand tapping was characterised by lower amounts of both linear and non-linear measures of variability than left hand tapping, and that linear and non-linear measures of variability were often negatively correlated with one another. Experiment 2 found that increased non-linear variability was associated with relatively enhanced performance on a closed-loop motor task (mirror tracing) and relatively impaired performance on an open-loop motor task (pointing in a dark room), especially for left hand performance. The potential uses and significance of measures of non-linear variability are discussed.

  18. Radionuclide stroke count ratios for assessment of right and left ventricular volume overload in children

    International Nuclear Information System (INIS)

    Parrish, M.D.; Graham, T.P. Jr.; Born, M.L.; Jones, J.P.; Boucek, R.J. Jr.; Artman, M.; Partain, C.L.

    1983-01-01

    The ratio of left ventricular to right ventricular stroke counts measured by radionuclide angiography has been used in adults to estimate the severity of left-sided valvular regurgitation. The validation of this technique in children for assessment of right and left ventricular volume overload is reported herein. Radionuclide stroke count ratios in 60 children aged 0.5 to 19 years (mean 11) were determined. Based on their diagnoses, the patients were divided into 3 groups: (1) normal--40 patients with no shunts or valvular regurgitation, (2) left ventricular volume overload--13 patients with mitral or aortic regurgitation, or both, and (3) right ventricular volume overload--7 patients, 2 with severe tricuspid regurgitation, 3 with atrial septal defects, and 2 with total anomalous pulmonary venous drainage. The radionuclide stroke count ratio clearly differentiated these groups (p less than 0.05): normal patients had a stroke count ratio of 1.04 +/- 0.17 (mean +/- 1 standard deviation), the left ventricular volume overload group had a stroke count ratio of 2.43 +/- 0.86, and the right ventricular volume overload group had a stroke count ratio of 0.44 +/- 0.17. In 22 of our 60 patients, radionuclide stroke count ratios were compared with cineangiographic stroke volume ratios, resulting in a correlation coefficient of 0.88. It is concluded that radionuclide ventriculography is an excellent tool for qualitative and quantitative assessment of valvular regurgitation in children

  19. The deviation matrix of a continuous-time Markov chain

    NARCIS (Netherlands)

    Coolen-Schrijner, P.; van Doorn, E.A.

    2001-01-01

    The deviation matrix of an ergodic, continuous-time Markov chain with transition probability matrix $P(.)$ and ergodic matrix $\\Pi$ is the matrix $D \\equiv \\int_0^{\\infty} (P(t)-\\Pi)dt$. We give conditions for $D$ to exist and discuss properties and a representation of $D$. The deviation matrix of a

  20. The deviation matrix of a continuous-time Markov chain

    NARCIS (Netherlands)

    Coolen-Schrijner, Pauline; van Doorn, Erik A.

    2002-01-01

    he deviation matrix of an ergodic, continuous-time Markov chain with transition probability matrix $P(.)$ and ergodic matrix $\\Pi$ is the matrix $D \\equiv \\int_0^{\\infty} (P(t)-\\Pi)dt$. We give conditions for $D$ to exist and discuss properties and a representation of $D$. The deviation matrix of a

  1. Statute of Limitations in Uruguay and the ethical-political essence of the left

    Directory of Open Access Journals (Sweden)

    Ana Buriano

    2011-07-01

    Full Text Available This paper compares parties and citizen behavior in the referendum and plebiscite of 1989 and 2009 in Uruguay, concerning the derogation or repeal of articles of the amnesty law, as well as the unfinished epilogue of this process. This will allow us to observe a change in the axis-force that drives citizens' initiatives in the matter. While in 1989 the Frente Amplio (FA assumed and promoted the derogatory referendum, in 2009 the social organizations won the centrality of the scene. In that last year the negative position and subsequent support for the plebiscite campaign by the partisan left. Its virtual absence from the coalition generates doubts about the management of the demands concerning human rights and the ethical-doctrinal nature of the partisan left. Although in 2010 the FA tried to resume leadership, it was weakened by an internal dispute that resulted in contempt towards the legislative debate to neutralize the effects of the act. The civic, identity and perhaps political configuration of the XXI century Uruguay will depend on the resolution of this gap.

  2. Suicidal behavior on Axis VI: clinical data supporting a sixth Axis for DSM-V.

    Science.gov (United States)

    Van Orden, Kimberly A; Witte, Tracy K; Holm-Denoma, Jill; Gordon, Kathryn H; Joiner, Thomas E

    2011-01-01

    Oquendo and colleagues (Oquendo, Baca-García, Mann, & Giner, 2008; Oquendo & Currier, 2009) recommend that DSM-V emphasize suicide risk assessment on a sixth axis, thereby increasing regularity of suicide risk assessments. We propose that evidence of nonredundancy with Axis V - Global Assessment of Functioning (GAF) is one piece of data that can serve as a starting point for a line of research establishing incremental predictive utility for a separate suicide risk assessment in the DSM framework. A standardized suicide risk assessment protocol, measures of depressive, anxious, and eating disordered symptomatology, as well as an index of comorbidity were administered to a sample of 412 adult outpatients. Our data indicate that data from standardized suicide risk assessments are associated with indices of symptomatology severity as well as comorbidity, controlling for GAF. These results support the nonredundancy of the assessments and suggest the utility of longitudinal investigations of the predictive utility of a sixth DSM axis in the assessment of suicide risk.

  3. 45 CFR 63.19 - Budget revisions and minor deviations.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Budget revisions and minor deviations. 63.19 Section 63.19 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION GRANT PROGRAMS... Budget revisions and minor deviations. Pursuant to § 74.102(d) of this title, paragraphs (b)(3) and (b)(4...

  4. Measurements of isocenter path characteristics of the gantry rotation axis with a smartphone application

    International Nuclear Information System (INIS)

    Schiefer, H.; Peters, S.; Plasswilm, L.; Ingulfsen, N.; Kluckert, J.

    2015-01-01

    Purpose: For stereotactic radiosurgery, the AAPM Report No. 54 [AAPM Task Group 42 (AAPM, 1995)] requires the overall stability of the isocenter (couch, gantry, and collimator) to be within a 1 mm radius. In reality, a rotating system has no rigid axis and thus no isocenter point which is fixed in space. As a consequence, the isocenter concept is reviewed here. It is the aim to develop a measurement method following the revised definitions. Methods: The mechanical isocenter is defined here by the point which rotates on the shortest path in the room coordinate system. The path is labeled as “isocenter path.” Its center of gravity is assumed to be the mechanical isocenter. Following this definition, an image-based and radiation-free measurement method was developed. Multiple marker pairs in a plane perpendicular to the assumed gantry rotation axis of a linear accelerator are imaged with a smartphone application from several rotation angles. Each marker pair represents an independent measuring system. The room coordinates of the isocenter path and the mechanical isocenter are calculated based on the marker coordinates. The presented measurement method is by this means strictly focused on the mechanical isocenter. Results: The measurement result is available virtually immediately following completion of measurement. When 12 independent measurement systems are evaluated, the standard deviations of the isocenter path points and mechanical isocenter coordinates are 0.02 and 0.002 mm, respectively. Conclusions: The measurement is highly accurate, time efficient, and simple to adapt. It is therefore suitable for regular checks of the mechanical isocenter characteristics of the gantry and collimator rotation axis. When the isocenter path is reproducible and its extent is in the range of the needed geometrical accuracy, it should be taken into account in the planning process. This is especially true for stereotactic treatments and radiosurgery

  5. Measurements of isocenter path characteristics of the gantry rotation axis with a smartphone application

    Energy Technology Data Exchange (ETDEWEB)

    Schiefer, H., E-mail: johann.schiefer@kssg.ch; Peters, S.; Plasswilm, L. [Klinik für Radio-Onkologie, Kantonsspital St.Gallen, Rorschacherstrasse 107, St.Gallen CH-9007 (Switzerland); Ingulfsen, N.; Kluckert, J. [Kantonsschule am Burggraben St.Gallen, Burggraben 21, St.Gallen CH-9000 (Switzerland)

    2015-03-15

    Purpose: For stereotactic radiosurgery, the AAPM Report No. 54 [AAPM Task Group 42 (AAPM, 1995)] requires the overall stability of the isocenter (couch, gantry, and collimator) to be within a 1 mm radius. In reality, a rotating system has no rigid axis and thus no isocenter point which is fixed in space. As a consequence, the isocenter concept is reviewed here. It is the aim to develop a measurement method following the revised definitions. Methods: The mechanical isocenter is defined here by the point which rotates on the shortest path in the room coordinate system. The path is labeled as “isocenter path.” Its center of gravity is assumed to be the mechanical isocenter. Following this definition, an image-based and radiation-free measurement method was developed. Multiple marker pairs in a plane perpendicular to the assumed gantry rotation axis of a linear accelerator are imaged with a smartphone application from several rotation angles. Each marker pair represents an independent measuring system. The room coordinates of the isocenter path and the mechanical isocenter are calculated based on the marker coordinates. The presented measurement method is by this means strictly focused on the mechanical isocenter. Results: The measurement result is available virtually immediately following completion of measurement. When 12 independent measurement systems are evaluated, the standard deviations of the isocenter path points and mechanical isocenter coordinates are 0.02 and 0.002 mm, respectively. Conclusions: The measurement is highly accurate, time efficient, and simple to adapt. It is therefore suitable for regular checks of the mechanical isocenter characteristics of the gantry and collimator rotation axis. When the isocenter path is reproducible and its extent is in the range of the needed geometrical accuracy, it should be taken into account in the planning process. This is especially true for stereotactic treatments and radiosurgery.

  6. The role of septal surgery in management of the deviated nose.

    Science.gov (United States)

    Foda, Hossam M T

    2005-02-01

    The deviated nose represents a complex cosmetic and functional problem. Septal surgery plays a central role in the successful management of the externally deviated nose. This study included 260 patients seeking rhinoplasty to correct external nasal deviations; 75 percent of them had various degrees of nasal obstruction. Septal surgery was necessary in 232 patients (89 percent), not only to improve breathing but also to achieve a straight, symmetrical, external nose as well. A graduated surgical approach was adopted to allow correction of the dorsal and caudal deviations of the nasal septum without weakening its structural support to the dorsum or nasal tip. The approach depended on full mobilization of deviated cartilage, followed by straightening of the cartilage and its fixation in the corrected position by using bony splinting grafts through an external rhinoplasty approach.

  7. Note onset deviations as musical piece signatures.

    Science.gov (United States)

    Serrà, Joan; Özaslan, Tan Hakan; Arcos, Josep Lluis

    2013-01-01

    A competent interpretation of a musical composition presents several non-explicit departures from the written score. Timing variations are perhaps the most important ones: they are fundamental for expressive performance and a key ingredient for conferring a human-like quality to machine-based music renditions. However, the nature of such variations is still an open research question, with diverse theories that indicate a multi-dimensional phenomenon. In the present study, we consider event-shift timing variations and show that sequences of note onset deviations are robust and reliable predictors of the musical piece being played, irrespective of the performer. In fact, our results suggest that only a few consecutive onset deviations are already enough to identify a musical composition with statistically significant accuracy. We consider a mid-size collection of commercial recordings of classical guitar pieces and follow a quantitative approach based on the combination of standard statistical tools and machine learning techniques with the semi-automatic estimation of onset deviations. Besides the reported results, we believe that the considered materials and the methodology followed widen the testing ground for studying musical timing and could open new perspectives in related research fields.

  8. Note onset deviations as musical piece signatures.

    Directory of Open Access Journals (Sweden)

    Joan Serrà

    Full Text Available A competent interpretation of a musical composition presents several non-explicit departures from the written score. Timing variations are perhaps the most important ones: they are fundamental for expressive performance and a key ingredient for conferring a human-like quality to machine-based music renditions. However, the nature of such variations is still an open research question, with diverse theories that indicate a multi-dimensional phenomenon. In the present study, we consider event-shift timing variations and show that sequences of note onset deviations are robust and reliable predictors of the musical piece being played, irrespective of the performer. In fact, our results suggest that only a few consecutive onset deviations are already enough to identify a musical composition with statistically significant accuracy. We consider a mid-size collection of commercial recordings of classical guitar pieces and follow a quantitative approach based on the combination of standard statistical tools and machine learning techniques with the semi-automatic estimation of onset deviations. Besides the reported results, we believe that the considered materials and the methodology followed widen the testing ground for studying musical timing and could open new perspectives in related research fields.

  9. An Analysis of the Linguistic Deviation in Chapter X of Oliver Twist

    Institute of Scientific and Technical Information of China (English)

    刘聪

    2013-01-01

    Charles Dickens is one of the greatest critical realist writers of the Victorian Age. In language, he is often compared with William Shakespeare for his adeptness with the vernacular and large vocabulary. Charles Dickens achieved a recognizable place among English writers through the use of the stylistic features in his fictional language. Oliver Twist is the best representative of Charles Dickens’style, which makes it the most appropriate choice for the present stylistic study on Charles Dickens. No one who has ever read the dehumanizing workhouse scenes of Oliver Twist and the dark, criminal underworld life can forget them. This thesis attempts to investigate Oliver Twist through the approach of modern stylistics, particularly the theory of linguistic devia-tion. This thesis consists of an introduction, the main body and a conclusion. The introduction offers a brief summary of the com-ments on Charles Dickens and Chapter X of Oliver Twist, introduces the newly rising linguistic deviation theories, and brings about the theories on which this thesis settles. The main body explores the deviation effects produced from four aspects: lexical deviation, grammatical deviation, graphological deviation, and semantic deviation. It endeavors to show Dickens ’manipulating language and the effects achieved through this manipulation. The conclusion mainly sums up the previous analysis, and reveals the theme of the novel, positive effect of linguistic deviation and significance of deviation application.

  10. Cobalt-60 total body irradiation dosimetry at 220 cm source-axis distance

    International Nuclear Information System (INIS)

    Glasgow, G.P.; Mill, W.B.

    1980-01-01

    Adults with acute leukemia are treated with cyclophosphamide and total body irradiation (TBI) followed by autologous marrow transplants. For TBI, patients seated in a stand angled 45 0 above the floor are treated for about 2 hours at 220 cm source-axis distance (SAD) with sequential right and left lateral 87 cm x 87 cm fields to a 900 rad mid-pelvic dose at about 8 rad/min using a 5000 Ci cobalt unit. Maximum (lateral) to minimum (mid-plane) dose ratios are: hips--1.15, shoulders--1.30, and head--1.05, which is shielded by a compensator filter. Organ doses are small intestine, liver and kidneys--1100 rad, lung--1100 to 1200 rad, and heart--1300 rad. Verification dosimetry reveals the prescribed dose is delivered to within +-5%. Details of the dosimetry of this treatment are presented

  11. Quantification of Global Left Ventricular Function: Comparison of Multidetector Computed Tomography and Magnetic Resonance Imaging. A Meta-analysis and Review of the Current Literature

    International Nuclear Information System (INIS)

    Vleuten, P.A. van der; Willems, T.P.; Goette, M.J.; Tio, R.A.; Greuter, M.J.; Zijlstra, F.; Oudkerk, M.

    2006-01-01

    Cardiac morbidity and mortality are closely related to cardiac volumes and global left ventricular (LV) function, expressed as left ventricular ejection fraction. Accurate assessment of these parameters is required for the prediction of prognosis in individual patients as well as in entire cohorts. The current standard of reference for left ventricular function is analysis by short-axis magnetic resonance imaging. In recent years, major extensive technological improvements have been achieved in computed tomography. The most marked development has been the introduction of the multidetector CT (MDCT), which has significantly improved temporal and spatial resolutions. In order to assess the current status of MDCT for analysis of LV function, the current available literature on this subject was reviewed. The data presented in this review indicate that the global left ventricular functional parameters measured by contemporary multi-detector row systems combined with adequate reconstruction algorithms and post-processing tools show a narrow diagnostic window and are interchangeable with those obtained by MRI

  12. Decreasing the amplitude deviation of Guassian filter in surface roughness measurements

    Science.gov (United States)

    Liu, Bo; Wang, Yu

    2008-12-01

    A new approach for decreasing the amplitude characteristic deviation of Guassian filter in surface roughness measurements is presented in this paper. According to Central Limit Theorem, many different Guassian approximation filters could be constructed. By using first-order Butterworth filter and moving average filter to approximate Guassian filter, their directions of amplitude deviation are opposite, and their locations of extreme value are close. So the linear combination of them could reduce the amplitude deviation greatly. The maximum amplitude deviation is only about 0.11% through paralleling them. The algorithm of this new method is simple and its efficiency is high.

  13. Major and minor axis kinematics of 22 ellipticals

    International Nuclear Information System (INIS)

    Franx, M.; Illingworth, G.; Heckman, T.

    1989-01-01

    Rotation curves and velocity dispersion profiles have been determined for the major and the minor axes of 22 elliptical galaxies. Rotation was detected in all but one galaxy, even though the sample was biased toward round ellipticals. Minor axis rotation larger than major axis rotation was measured in two galaxies, NGC 4406 and NGC 7507. Roughly 10 percent of ellipticals may show large minor axis velocities relative to those on the major axis. A simple model is used to derive a rotational axis from the observed minor and major axis velocities to a typical accuracy of 6 deg. The rotational and photometric minor axes aligned to better than 10 deg for 60 percent of the sample, implying that the direction of the angular momentum is related to the orientation of the figure of the galaxy. IC 1459 has a kinematically distinct core with its angular momentum opposite to the angular momentum of the outer parts, and NGC 4406 has a core with its angular momentum perpendicular to that of the outer parts. 46 refs

  14. Left passage probability of Schramm-Loewner Evolution

    Science.gov (United States)

    Najafi, M. N.

    2013-06-01

    SLE(κ,ρ⃗) is a variant of Schramm-Loewner Evolution (SLE) which describes the curves which are not conformal invariant, but are self-similar due to the presence of some other preferred points on the boundary. In this paper we study the left passage probability (LPP) of SLE(κ,ρ⃗) through field theoretical framework and find the differential equation governing this probability. This equation is numerically solved for the special case κ=2 and hρ=0 in which hρ is the conformal weight of the boundary changing (bcc) operator. It may be referred to loop erased random walk (LERW) and Abelian sandpile model (ASM) with a sink on its boundary. For the curve which starts from ξ0 and conditioned by a change of boundary conditions at x0, we find that this probability depends significantly on the factor x0-ξ0. We also present the perturbative general solution for large x0. As a prototype, we apply this formalism to SLE(κ,κ-6) which governs the curves that start from and end on the real axis.

  15. Effective shunt impedance comparison between s-band standing wave accelerators with on-axis and off-axis couplers

    International Nuclear Information System (INIS)

    Schriber, S.O.; Funk, L.W.; Hutcheon, R.M.

    1976-01-01

    The effective shunt impedances of a side-coupled S-band standing wave accelerating structure and a structure employing on-axis couplers have been compared by measuring the energy of accelerated electrons. Criteria for choosing an on-axis coupled structure compared to side-coupled and ''disk and washer'' accelerating structures are given. (author)

  16. Assessment of left ventricular torsion and untwisting in patients suffering from dilated cardiomyopathy by velocity vector imaging

    Directory of Open Access Journals (Sweden)

    Xiao-juan ZHANG

    2015-10-01

    Full Text Available Objective To evaluate the characteristics of left ventricular twisting (LVtw and untwisting (LVuntw in patients with dilated cardiomyopathy (DCM. Methods Nineteen DCM patients (aged 18-82 years, mean 50.52±17.52 years, 2 females and 21 normal controls (aged 18-80 years, mean 49.05±16.94 years, 5 females were enrolled in present study. Basal and apical short axis view of two-dimensional images of left ventricle were obtained to analyze LV rotation, and the LV rotation velocity was detected by velocity vector imaging (VVI. LVtw, LVtw velocity, untwisting velocity and untwisting rate (untwR were calculated. Results The rotated degree and velocity of the basal and apical parts of LV myocardium were irregularly changed along with the cardiac cycle in the DCM group. The rotation degree and rotation velocity at the basal and apex axis decreased in DCM group compared with that in normal group, while the peak of twisting (Ptw [(6.49±1.82°] and the peak of twisting velocity (PTV [(67.84±15.60°/s] decreased significantly in DCM group. The untwR and peak of untwisting velocity (PUV were also decreased significantly in DCM patients. Conclusion The Ptw, PTV and PUV decrease significantly, and the LV untwR, impacted by the preload, is also decreased significantly in DCM patients. DOI: 10.11855/j.issn.0577-7402.2015.09.13

  17. ECG-gated blood pool tomography in the determination of left ventricular volume, ejection fraction, and wall motion

    International Nuclear Information System (INIS)

    Underwood, S.R.; Ell, P.J.; Jarritt, P.H.; Emanuel, R.W.; Swanton, R.H.

    1984-01-01

    ECG-gated blood pool tomography promises to provide a ''gold standard'' for noninvasive measurement of left ventricular volume, ejection fraction, and wall motion. This study compares these measurements with those from planar radionuclide imaging and contrast ventriculography. End diastolic and end systolic blood pool images were acquired tomographically using an IGE400A rotating gamma camera and Star computer, and slices were reconstructed orthogonal to the long axis of the heart. Left ventricular volume was determined by summing the areas of the slices, and wall motion was determined by comparison of end diastolic and end systolic contours. In phantom experiments this provided an accurate measurement of volume (r=0.98). In 32 subjects who were either normal or who had coronary artery disease left ventricular volume (r=0.83) and ejection fraction (r=0.89) correlated well with those using a counts based planar technique. In 16 of 18 subjects who underwent right anterior oblique X-ray contrast ventriculography, tomographic wall motion agreed for anterior, apical, and inferior walls, but abnormal septal motion which was not apparent by contrast ventriculography, was seen in 12 subjects tomographically. All 12 had disease of the left anterior descending coronary artery and might have been expected to have abnormal septal motion. ECG-gated blood pool tomography can thus determine left ventricular volume and ejection fraction accurately, and provides a global description of wall motion in a way that is not possible from any single planar image

  18. Minimizing Hexapod Robot Foot Deviations Using Multilayer Perceptron

    Directory of Open Access Journals (Sweden)

    Vytautas Valaitis

    2015-12-01

    Full Text Available Rough-terrain traversability is one of the most valuable characteristics of walking robots. Even despite their slower speeds and more complex control algorithms, walking robots have far wider usability than wheeled or tracked robots. However, efficient movement over irregular surfaces can only be achieved by eliminating all possible difficulties, which in many cases are caused by a high number of degrees of freedom, feet slippage, frictions and inertias between different robot parts or even badly developed inverse kinematics (IK. In this paper we address the hexapod robot-foot deviation problem. We compare the foot-positioning accuracy of unconfigured inverse kinematics and Multilayer Perceptron-based (MLP methods via theory, computer modelling and experiments on a physical robot. Using MLP-based methods, we were able to significantly decrease deviations while reaching desired positions with the hexapod's foot. Furthermore, this method is able to compensate for deviations of the robot arising from any possible reason.

  19. Systolic left ventricular function according to left ventricular concentricity and dilatation in hypertensive patients

    DEFF Research Database (Denmark)

    Bang, Casper; Gerdts, Eva; Aurigemma, Gerard P

    2013-01-01

    Left ventricular hypertrophy [LVH, high left ventricular mass (LVM)] is traditionally classified as concentric or eccentric based on left ventricular relative wall thickness. We evaluated left ventricular systolic function in a new four-group LVH classification based on left ventricular dilatation...... [high left ventricular end-diastolic volume (EDV) index and concentricity (LVM/EDV)] in hypertensive patients....

  20. The Impact of Advanced Technologies on Treatment Deviations in Radiation Treatment Delivery

    International Nuclear Information System (INIS)

    Marks, Lawrence B.; Light, Kim L.; Hubbs, Jessica L.; Georgas, Debra L.; Jones, Ellen L.; Wright, Melanie C.; Willett, Christopher G.; Yin Fangfang

    2007-01-01

    Purpose: To assess the impact of new technologies on deviation rates in radiation therapy (RT). Methods and Materials: Treatment delivery deviations in RT were prospectively monitored during a time of technology upgrade. In January 2003, our department had three accelerators, none with 'modern' technologies (e.g., without multileaf collimators [MLC]). In 2003 to 2004, we upgraded to five new accelerators, four with MLC, and associated advanced capabilities. The deviation rates among patients treated on 'high-technology' versus 'low-technology' machines (defined as those with vs. without MLC) were compared over time using the two-tailed Fisher's exact test. Results: In 2003, there was no significant difference between the deviation rate in the 'high-technology' versus 'low-technology' groups (0.16% vs. 0.11%, p = 0.45). In 2005 to 2006, the deviation rate for the 'high-technology' groups was lower than the 'low-technology' (0.083% vs. 0.21%, p = 0.009). This difference was caused by a decline in deviations on the 'high-technology' machines over time (p = 0.053), as well as an unexpected trend toward an increase in deviations over time on the 'low-technology' machines (p = 0.15). Conclusions: Advances in RT delivery systems appear to reduce the rate of treatment deviations. Deviation rates on 'high-technology' machines with MLC decline over time, suggesting a learning curve after the introduction of new technologies. Associated with the adoption of 'high-technology' was an unexpected increase in the deviation rate with 'low-technology' approaches, which may reflect an over-reliance on tools inherent to 'high-technology' machines. With the introduction of new technologies, continued diligence is needed to ensure that staff remain proficient with 'low-technology' approaches

  1. Advanced Age Attenuates Left Ventricular Filling Efficiency Quantified Using Vortex Formation Time: A Study of Octogenarians With Normal Left Ventricular Systolic Function Undergoing Coronary Artery Surgery.

    Science.gov (United States)

    Pagel, Paul S; Dye, Lonnie; Boettcher, Brent T; Freed, Julie K

    2018-03-07

    Blood flow across the mitral valve during early left ventricular (LV) filling produces a 3-dimensional rotational fluid body, known as a vortex ring, that enhances LV filling efficiency. Diastolic dysfunction is common in elderly patients, but the influence of advanced age on vortex formation is unknown. The authors tested the hypothesis that advanced age is associated with a reduction in LV filling efficiency quantified using vortex formation time (VFT) in octogenarians undergoing coronary artery bypass graft (CABG) surgery. Observational study. Veterans Affairs medical center. After institutional review board approval, octogenarians (n = 7; 82 ± 2 year [mean ± standard deviation]; ejection fraction 56% ± 7%) without valve disease or atrial arrhythmias undergoing CABG were compared with a younger cohort (n = 7; 55 ± 6 year; ejection fraction 57% ± 7%) who were undergoing coronary revascularization. None. All patients were monitored using radial and pulmonary arterial catheters and transesophageal echocardiography. Peak early LV filling (E) and atrial systole (A) blood flow velocities and their corresponding velocity-time integrals were obtained using pulse-wave Doppler echocardiography to determine E/A, atrial filling fraction (β), and E wave deceleration time. Pulse-wave Doppler also was used to measure pulmonary venous blood flow during systole and diastole. Mitral valve diameter (D) was calculated as the average of major and minor axis lengths obtained in the midesophageal LV bicommissural and long-axis transesophageal echocardiography imaging planes, respectively. VFT was calculated as 4 × (1 - β) × SV/(πD 3 ), where SV is the stroke volume measured using thermodilution. Systemic and pulmonary hemodynamics, LV diastolic function, and VFT were determined during steady-state conditions 30 minutes before cardiopulmonary bypass. A delayed relaxation pattern of LV filling (E/A 0.81 ± 0.16 v 1.29 ± 0.19, p = 0.00015; β 0.44 ± 0.05 v 0.35 ± 0.03, p = 0

  2. Nitric oxide in the stress axis.

    Science.gov (United States)

    López-Figueroa, M O; Day, H E; Akil, H; Watson, S J

    1998-10-01

    In recent years nitric oxide (NO) has emerged as a unique biological messenger. NO is a highly diffusible gas, synthesized from L-arginine by the enzyme nitric oxide synthase (NOS). Three unique subtypes of NOS have been described, each with a specific distribution profile in the brain and periphery. NOS subtype I is present, among other areas, in the hippocampus, hypothalamus, pituitary and adrenal gland. Together these structures form the limbic-hypothalamic-pituitary-adrenal (LHPA) or stress axis, activation of which is one of the defining features of a stress response. Evidence suggests that NO may modulate the release of the stress hormones ACTH and corticosterone, and NOS activity and transcription is increased in the LHPA axis following various stressful stimuli. Furthermore, following activation of the stress axis, glucocorticoids are thought to down-regulate the transcription and activity of NOS via a feedback mechanism. Taken together, current data indicate a role for NO in the regulation of the LHPA axis, although at present this role is not well defined. It has been suggested that NO may act as a cellular communicator in plasticity and development, to facilitate the activation or the release of other neurotransmitters, to mediate immune responses, and/or as a vasodilator in the regulation of blood flow. In the following review we summarize some of the latest insights into the function of NO, with special attention to its relationship with the LHPA axis.

  3. Neutral axis as damage sensitive feature

    International Nuclear Information System (INIS)

    Sigurdardottir, D H; Glisic, B

    2013-01-01

    Structural health monitoring (SHM) is the process of continuously or periodically measuring structural parameters and the transformation of the collected data into information on real structural conditions. The centroid of stiffness is a universal parameter and its position in a cross-section can be evaluated for any load-carrying beam structure as the position of the neutral axis under conveniently chosen loads. Thus, a change in the position of the neutral axis within a cross-section can indicate a change in the position of the centroid of stiffness, i.e., unusual structural behaviors. This paper proposes a novel monitoring method based on deterministic and probabilistic determination of the position of the neutral axis under conveniently chosen conditions. Therefore, the method proposed in this paper is potentially applicable to a large variety of beam-like structures. Data from two existing structures were used to validate the method and assess its performance: Streicker Bridge at Princeton University and the US202/NJ23 highway overpass in Wayne, NJ. The results show that the neutral axis location is varying even when damage is not present. Reasons for this variation are determined and the accuracy in the evaluation assessed. This paper concludes that the position of the neutral axis can be evaluated with sufficient accuracy using static and dynamic strain measurements performed on appropriate time-scales and indicates its potential to be used as a damage sensitive feature. (paper)

  4. Neutral axis as damage sensitive feature

    Science.gov (United States)

    Sigurdardottir, D. H.; Glisic, B.

    2013-07-01

    Structural health monitoring (SHM) is the process of continuously or periodically measuring structural parameters and the transformation of the collected data into information on real structural conditions. The centroid of stiffness is a universal parameter and its position in a cross-section can be evaluated for any load-carrying beam structure as the position of the neutral axis under conveniently chosen loads. Thus, a change in the position of the neutral axis within a cross-section can indicate a change in the position of the centroid of stiffness, i.e., unusual structural behaviors. This paper proposes a novel monitoring method based on deterministic and probabilistic determination of the position of the neutral axis under conveniently chosen conditions. Therefore, the method proposed in this paper is potentially applicable to a large variety of beam-like structures. Data from two existing structures were used to validate the method and assess its performance: Streicker Bridge at Princeton University and the US202/NJ23 highway overpass in Wayne, NJ. The results show that the neutral axis location is varying even when damage is not present. Reasons for this variation are determined and the accuracy in the evaluation assessed. This paper concludes that the position of the neutral axis can be evaluated with sufficient accuracy using static and dynamic strain measurements performed on appropriate time-scales and indicates its potential to be used as a damage sensitive feature.

  5. Large-Deviation Results for Discriminant Statistics of Gaussian Locally Stationary Processes

    Directory of Open Access Journals (Sweden)

    Junichi Hirukawa

    2012-01-01

    Full Text Available This paper discusses the large-deviation principle of discriminant statistics for Gaussian locally stationary processes. First, large-deviation theorems for quadratic forms and the log-likelihood ratio for a Gaussian locally stationary process with a mean function are proved. Their asymptotics are described by the large deviation rate functions. Second, we consider the situations where processes are misspecified to be stationary. In these misspecified cases, we formally make the log-likelihood ratio discriminant statistics and derive the large deviation theorems of them. Since they are complicated, they are evaluated and illustrated by numerical examples. We realize the misspecification of the process to be stationary seriously affecting our discrimination.

  6. Accuracy of outcome anticipation, but not gaze behavior, differs against left- and right-handed penalties in team-handball goalkeeping

    Directory of Open Access Journals (Sweden)

    Florian eLoffing

    2015-12-01

    Full Text Available Low perceptual familiarity with relatively rarer left-handed as opposed to more common right-handed individuals may result in athletes’ poorer ability to anticipate the former’s action intentions. Part of such left-right asymmetry in visual anticipation could be due to an inefficient gaze strategy during confrontation with left-handed individuals. To exemplify, observers may not mirror their gaze when viewing left- vs. right-handed actions but preferentially fixate on an opponent’s right body side, irrespective of an opponent’s handedness, owing to the predominant exposure to right-handed actions. So far empirical verification of such assumption, however, is lacking. Here we report on an experiment where team-handball goalkeepers’ and non-goalkeepers’ gaze behavior was recorded while they predicted throw direction of left- and right-handed seven-meter penalties shown as videos on a computer monitor. As expected, goalkeepers were considerably more accurate than non-goalkeepers and prediction was better against right- than left-handed penalties. However, there was no indication of differences in gaze measures (i.e., number of fixations, overall and final fixation duration, time-course of horizontal or vertical fixation deviation as a function of skill group or the penalty-takers’ handedness. Findings suggest that inferior anticipation of left-handed compared to right-handed individuals’ action intentions may not be associated with misalignment in gaze behavior. Rather, albeit looking similarly, accuracy differences could be due to observers’ differential ability of picking up and interpreting the visual information provided by left- vs. right-handed movements.

  7. Accuracy of Outcome Anticipation, But Not Gaze Behavior, Differs Against Left- and Right-Handed Penalties in Team-Handball Goalkeeping

    Science.gov (United States)

    Loffing, Florian; Sölter, Florian; Hagemann, Norbert; Strauss, Bernd

    2015-01-01

    Low perceptual familiarity with relatively rarer left-handed as opposed to more common right-handed individuals may result in athletes' poorer ability to anticipate the former's action intentions. Part of such left-right asymmetry in visual anticipation could be due to an inefficient gaze strategy during confrontation with left-handed individuals. To exemplify, observers may not mirror their gaze when viewing left- vs. right-handed actions but preferentially fixate on an opponent's right body side, irrespective of an opponent's handedness, owing to the predominant exposure to right-handed actions. So far empirical verification of such assumption, however, is lacking. Here we report on an experiment where team-handball goalkeepers' and non-goalkeepers' gaze behavior was recorded while they predicted throw direction of left- and right-handed 7-m penalties shown as videos on a computer monitor. As expected, goalkeepers were considerably more accurate than non-goalkeepers and prediction was better against right- than left-handed penalties. However, there was no indication of differences in gaze measures (i.e., number of fixations, overall and final fixation duration, time-course of horizontal or vertical fixation deviation) as a function of skill group or the penalty-takers' handedness. Findings suggest that inferior anticipation of left-handed compared to right-handed individuals' action intentions may not be associated with misalignment in gaze behavior. Rather, albeit looking similarly, accuracy differences could be due to observers' differential ability of picking up and interpreting the visual information provided by left- vs. right-handed movements. PMID:26648887

  8. A robust standard deviation control chart

    NARCIS (Netherlands)

    Schoonhoven, M.; Does, R.J.M.M.

    2012-01-01

    This article studies the robustness of Phase I estimators for the standard deviation control chart. A Phase I estimator should be efficient in the absence of contaminations and resistant to disturbances. Most of the robust estimators proposed in the literature are robust against either diffuse

  9. Analysis of laryngoscopic features in patients with unilateral vocal fold paresis.

    Science.gov (United States)

    Woo, Peak; Parasher, Arjun K; Isseroff, Tova; Richards, Amanda; Sivak, Mark

    2016-08-01

    The diagnosis of paresis in patients with vocal fold motion impairment remains a challenge. More than 27 clinical parameters have been cited that may signify paresis. We hypothesize that some features are more significant than others. Prospective case series. Two laryngologists rated laryngoscopy findings in 19 patients suspected of paresis. The diagnosis was confirmed with laryngeal electromyography. A standard set of 27 ratings was used for each examination that included movement, laryngeal configuration, and stroboscopy signs. A Fisher exact test was completed for each measure. A kappa coefficient was calculated for effectiveness in predicting the laterality of paresis. Left-sided vocal fold paresis (n = 13) was significantly associated with ipsilateral axis deviation, thinner vocal fold, bowing, reduced movement, reduced kinesis, and phase lag (P vocal fold paresis (n = 6) was significantly associated with ipsilateral shorter vocal fold, axis deviation, reduced movement, and reduced kinesis (P vocal fold, vocal fold bowing, reduced movement, reduced kinesis, and phase lag were more likely to be associated with vocal fold paresis. 4 Laryngoscope, 126:1831-1836, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  10. A Bayesian Approach for Summarizing and Modeling Time-Series Exposure Data with Left Censoring.

    Science.gov (United States)

    Houseman, E Andres; Virji, M Abbas

    2017-08-01

    Direct reading instruments are valuable tools for measuring exposure as they provide real-time measurements for rapid decision making. However, their use is limited to general survey applications in part due to issues related to their performance. Moreover, statistical analysis of real-time data is complicated by autocorrelation among successive measurements, non-stationary time series, and the presence of left-censoring due to limit-of-detection (LOD). A Bayesian framework is proposed that accounts for non-stationary autocorrelation and LOD issues in exposure time-series data in order to model workplace factors that affect exposure and estimate summary statistics for tasks or other covariates of interest. A spline-based approach is used to model non-stationary autocorrelation with relatively few assumptions about autocorrelation structure. Left-censoring is addressed by integrating over the left tail of the distribution. The model is fit using Markov-Chain Monte Carlo within a Bayesian paradigm. The method can flexibly account for hierarchical relationships, random effects and fixed effects of covariates. The method is implemented using the rjags package in R, and is illustrated by applying it to real-time exposure data. Estimates for task means and covariates from the Bayesian model are compared to those from conventional frequentist models including linear regression, mixed-effects, and time-series models with different autocorrelation structures. Simulations studies are also conducted to evaluate method performance. Simulation studies with percent of measurements below the LOD ranging from 0 to 50% showed lowest root mean squared errors for task means and the least biased standard deviations from the Bayesian model compared to the frequentist models across all levels of LOD. In the application, task means from the Bayesian model were similar to means from the frequentist models, while the standard deviations were different. Parameter estimates for covariates

  11. Deviation from Covered Interest Rate Parity in Korea

    Directory of Open Access Journals (Sweden)

    Seungho Lee

    2003-06-01

    Full Text Available This paper tested the factors which cause deviation from covered interest rate parity (CIRP in Korea, using regression and VAR models. The empirical evidence indicates that the difference between the swap rate and interest rate differential exists and is greatly affected by variables which represent the currency liquidity situation of foreign exchange banks. In other words, the deviation from CIRP can easily occur due to the lack of foreign exchange liquidity of banks in a thin market, despite few capital constraints, small transaction costs, and trivial default risk in Korea.

  12. The Assessment of Left Ventricular Time-Varying Radius Using Tissue Doppler Imaging

    Directory of Open Access Journals (Sweden)

    Fardin Mirbolouk

    2012-03-01

    Full Text Available Background: Left ventricular twist/torsion is believed to be a sensitive indicator of systolic and diastolic performance. To obtain circumferential rotation using tissue Doppler imaging, we need to estimate the time-varying radius of the left ventricle throughout the cardiac cycle to convert the tangential velocity into angular velocity. Objectives: The aim of this study was to investigate accuracy of measured LV radius using tissue Doppler imaging throughout the cardiac cycle compared to two-dimensional (2D imaging. Methods: A total of 35 subjects (47±12 years old underwent transthoracic echocardiographic standard examinations. Left ventricular radius during complete cardiac cycle measured using tissue Doppler and 2D-imaging at basal and apical short axis levels. For this reason, the 2D-images and velocity-time data derived and transferred to a personal computer for off-line analysis. 2D image frames analyzed via a program written in the MATLAB software. Velocity-time data from anteroseptal at basal level (or anterior wall at apical level and posterior walls transferred to a spreadsheet Excel program for the radius calculations. Linear correlation and Bland-Altman analysis were calculated to assess the relationships and agreements between the tissue Doppler and 2D-measured radii throughout the cardiac cycle. Results: There was significant correlation between tissue Doppler and 2D-measured radii and the Pearson correlation coefficients were 0.84 to 0.97 (P<0.05. Bland-Altman analysis by constructing the 95% limits of agreement showed that the good agreements existed between the two methods. Conclusion: It can be concluded from our experience that the tissue Doppler imaging can reasonably estimate radius of the left ventricle throughout the cardiac cycle.

  13. Statistics as Unbiased Estimators: Exploring the Teaching of Standard Deviation

    Science.gov (United States)

    Wasserman, Nicholas H.; Casey, Stephanie; Champion, Joe; Huey, Maryann

    2017-01-01

    This manuscript presents findings from a study about the knowledge for and planned teaching of standard deviation. We investigate how understanding variance as an unbiased (inferential) estimator--not just a descriptive statistic for the variation (spread) in data--is related to teachers' instruction regarding standard deviation, particularly…

  14. A better norm-referenced grading using the standard deviation criterion.

    Science.gov (United States)

    Chan, Wing-shing

    2014-01-01

    The commonly used norm-referenced grading assigns grades to rank-ordered students in fixed percentiles. It has the disadvantage of ignoring the actual distance of scores among students. A simple norm-referenced grading via standard deviation is suggested for routine educational grading. The number of standard deviation of a student's score from the class mean was used as the common yardstick to measure achievement level. Cumulative probability of a normal distribution was referenced to help decide the amount of students included within a grade. RESULTS of the foremost 12 students from a medical examination were used for illustrating this grading method. Grading by standard deviation seemed to produce better cutoffs in allocating an appropriate grade to students more according to their differential achievements and had less chance in creating arbitrary cutoffs in between two similarly scored students than grading by fixed percentile. Grading by standard deviation has more advantages and is more flexible than grading by fixed percentile for norm-referenced grading.

  15. Left-handedness and health

    Directory of Open Access Journals (Sweden)

    Milenković Sanja

    2010-01-01

    Full Text Available Hand dominance is defined as a proneness to use one hand rather than another in performing the majority of activities and this is the most obvious example of cerebral lateralization and an exclusive human characteristic. Left-handed people comprise 6-14% of the total population, while in Serbia, this percentage is 5-10%, moving from undeveloped to developed environments, where a socio-cultural pressure is less present. There is no agreement between investigators who in fact may be considered a left-handed person, about the percentage of left-handers in the population and about the etiology of left-handedness. In the scientific literature left-handedness has been related to health disorders (spine deformities, immunological disorders, migraine, neurosis, depressive psychosis, schizophrenia, insomnia, homosexuality, diabetes mellitus, arterial hypertension, sleep apnea, enuresis nocturna and Down Syndrome, developmental disorders (autism, dislexia and sttutering and traumatism. The most reliable scientific evidences have been published about the relationship between left-handedness and spinal deformities in school children in puberty and with traumatism in general population. The controversy of other results in up-to-now investigations of health aspects of left-handedness may partly be explained by a scientific disagreement whether writing with the left hand is a sufficient criterium for left-handedness, or is it necessary to investigate other parameters for laterality assessment. Explanation of health aspects of left-handedness is dominantly based on Geschwind-Galaburda model about 'anomalous' cerebral domination, as a consequence of hormonal disbalance. .

  16. [Left-handedness and health].

    Science.gov (United States)

    Milenković, Sanja; Belojević, Goran; Kocijancić, Radojka

    2010-01-01

    Hand dominance is defined as a proneness to use one hand rather than another in performing the majority of activities and this is the most obvious example of cerebral lateralization and an exclusive human characteristic. Left-handed people comprise 6-14% of the total population, while in Serbia, this percentage is 5-10%, moving from undeveloped to developed environments, where a socio-cultural pressure is less present. There is no agreement between investigators who in fact may be considered a left-handed person, about the percentage of left-handers in the population and about the etiology of left-handedness. In the scientific literature left-handedness has been related to health disorders (spine deformities, immunological disorders, migraine, neurosis, depressive psychosis, schizophrenia, insomnia, homosexuality, diabetes mellitus, arterial hypertension, sleep apnea, enuresis nocturna and Down Syndrome), developmental disorders (autism, dislexia and sttutering) and traumatism. The most reliable scientific evidences have been published about the relationship between left-handedness and spinal deformities in school children in puberty and with traumatism in general population. The controversy of other results in up-to-now investigations of health aspects of left-handedness may partly be explained by a scientific disagreement whether writing with the left hand is a sufficient criterium for left-handedness, or is it necessary to investigate other parameters for laterality assessment. Explanation of health aspects of left-handedness is dominantly based on Geschwind-Galaburda model about "anomalous" cerebral domination, as a consequence of hormonal disbalance.

  17. Particle orbit analysis for LHD helical axis configurations

    International Nuclear Information System (INIS)

    Guasp, J.; Yamazaki, K.; Motojima, O.

    1993-04-01

    Fast ion orbits for helical magnetic axis configurations in LHD (Large Helical Device) are analyzed and compared with the standard circular axis case. Boundaries between passing and helically trapped particle regions show clear differences: in the non-planar axis case the helically trapped region spreads, near the magnetic axis, over a much wider band across the 90deg pitch angle value and shows a very marked asymmetry. The locally trapped particle region is also wider than in the standard case. The differences in the loss cone boundaries of the two cases are rather small, however, the effects of re-entering criteria are very important in both cases. On the contrary, effects of finite coil size are not significant. (author)

  18. Impact of age, sex, and indexation method on MR left ventricular reference values in the Framingham Heart Study offspring cohort.

    Science.gov (United States)

    Yeon, Susan B; Salton, Carol J; Gona, Philimon; Chuang, Michael L; Blease, Susan J; Han, Yuchi; Tsao, Connie W; Danias, Peter G; Levy, Daniel; O'Donnell, Christopher J; Manning, Warren J

    2015-04-01

    To determine normative values for left ventricular (LV) volumes, mass, concentricity, and ejection fraction (EF) and investigate associations between sex, age, and body size with LV parameters in community-dwelling adults. In all, 1794 Framingham Heart Study Offspring cohort members underwent LV short-axis oriented, contiguous multislice cine steady-state free precession MR of the left ventricle; from these a healthy referent group (n = 852, 61 ± 9 years, 40% men) free of clinical cardiac disease and hypertension (SBP 65 years); LV parameters were indexed to measures of body size. Men have greater LV volumes and mass than women both before and after indexation to height, powers of height, and body surface area (P J. Magn. Reson. Imaging 2015;41:1038-1045. © 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.

  19. Dynamic Modeling of Starting Aerodynamics and Stage Matching in an Axi-Centrifugal Compressor

    Science.gov (United States)

    Wilkes, Kevin; OBrien, Walter F.; Owen, A. Karl

    1996-01-01

    A DYNamic Turbine Engine Compressor Code (DYNTECC) has been modified to model speed transients from 0-100% of compressor design speed. The impetus for this enhancement was to investigate stage matching and stalling behavior during a start sequence as compared to rotating stall events above ground idle. The model can simulate speed and throttle excursions simultaneously as well as time varying bleed flow schedules. Results of a start simulation are presented and compared to experimental data obtained from an axi-centrifugal turboshaft engine and companion compressor rig. Stage by stage comparisons reveal the front stages to be operating in or near rotating stall through most of the start sequence. The model matches the starting operating line quite well in the forward stages with deviations appearing in the rearward stages near the start bleed. Overall, the performance of the model is very promising and adds significantly to the dynamic simulation capabilities of DYNTECC.

  20. Energy Efficient Hybrid Dual Axis Solar Tracking System

    Directory of Open Access Journals (Sweden)

    Rashid Ahammed Ferdaus

    2014-01-01

    Full Text Available This paper describes the design and implementation of an energy efficient solar tracking system from a normal mechanical single axis to a hybrid dual axis. For optimizing the solar tracking mechanism electromechanical systems were evolved through implementation of different evolutional algorithms and methodologies. To present the tracker, a hybrid dual-axis solar tracking system is designed, built, and tested based on both the solar map and light sensor based continuous tracking mechanism. These light sensors also compare the darkness and cloudy and sunny conditions assisting daily tracking. The designed tracker can track sun’s apparent position at different months and seasons; thereby the electrical controlling device requires a real time clock device for guiding the tracking system in seeking solar position for the seasonal motion. So the combination of both of these tracking mechanisms made the designed tracker a hybrid one. The power gain and system power consumption are compared with a static and continuous dual axis solar tracking system. It is found that power gain of hybrid dual axis solar tracking system is almost equal to continuous dual axis solar tracking system, whereas the power saved in system operation by the hybrid tracker is 44.44% compared to the continuous tracking system.

  1. Triple axis spectrometers

    International Nuclear Information System (INIS)

    Clausen, K.N.

    1997-01-01

    Conventional triple-axis neutron spectroscopy was developed by Brockhouse over thirty years ago' and remains today a versatile and powerful tool for probing the dynamics of condensed matter. The original design of the triple axis spectrometer is technically simple and probes momentum and energy space on a point-by-point basis. This ability to systematically probe the scattering function in a way which only requires a few angles to be moved under computer control and where the observed data in general can be analysed using a pencil and graph paper or a simple fitting routine, has been essential for the success of the method. These constraints were quite reasonable at the time the technique was developed. Advances in computer based data acquisition, neutron beam optics, and position sensitive area detectors have been gradually implemented on many triple axis spectrometer spectrometers, but the full potential of this has not been fully exploited yet. Further improvement in terms of efficiency (beyond point by point inspection) and increased sensitivity (use of focusing optics whenever the problem allows it) could easily be up to a factor of 10-20 over present instruments for many problems at a cost which is negligible compared to that of increasing the flux of the source. The real cost will be in complexity - finding the optimal set-up for a given scan and interpreting the data as the they are taken. On-line transformation of the data for an appropriate display in Q, ω space and analysis tools will be equally important for this task, and the success of these new ideas will crucially depend on how well we solve these problems. (author)

  2. Automatic segmentation of left ventricle in cardiac cine MRI images based on deep learning

    Science.gov (United States)

    Zhou, Tian; Icke, Ilknur; Dogdas, Belma; Parimal, Sarayu; Sampath, Smita; Forbes, Joseph; Bagchi, Ansuman; Chin, Chih-Liang; Chen, Antong

    2017-02-01

    In developing treatment of cardiovascular diseases, short axis cine MRI has been used as a standard technique for understanding the global structural and functional characteristics of the heart, e.g. ventricle dimensions, stroke volume and ejection fraction. To conduct an accurate assessment, heart structures need to be segmented from the cine MRI images with high precision, which could be a laborious task when performed manually. Herein a fully automatic framework is proposed for the segmentation of the left ventricle from the slices of short axis cine MRI scans of porcine subjects using a deep learning approach. For training the deep learning models, which generally requires a large set of data, a public database of human cine MRI scans is used. Experiments on the 3150 cine slices of 7 porcine subjects have shown that when comparing the automatic and manual segmentations the mean slice-wise Dice coefficient is about 0.930, the point-to-curve error is 1.07 mm, and the mean slice-wise Hausdorff distance is around 3.70 mm, which demonstrates the accuracy and robustness of the proposed inter-species translational approach.

  3. Sea Surface Height Deviation, Aviso, 0.25 degrees, Global, Science Quality

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Aviso Sea Surface Height Deviation is the deviation from the mean geoid as measured from 1993 - 1995. This is Science Quality data.

  4. 48 CFR 201.404 - Class deviations.

    Science.gov (United States)

    2010-10-01

    ..., and the Defense Logistics Agency, may approve any class deviation, other than those described in 201...) Diminish any preference given small business concerns by the FAR or DFARS; or (D) Extend to requirements imposed by statute or by regulations of other agencies such as the Small Business Administration and the...

  5. Microbiota-Brain-Gut Axis and Neurodegenerative Diseases.

    Science.gov (United States)

    Quigley, Eamonn M M

    2017-10-17

    The purposes of this review were as follows: first, to provide an overview of the gut microbiota and its interactions with the gut and the central nervous system (the microbiota-gut-brain axis) in health, second, to review the relevance of this axis to the pathogenesis of neurodegenerative diseases, such as Parkinson's disease, and, finally, to assess the potential for microbiota-targeted therapies. Work on animal models has established the microbiota-gut-brain axis as a real phenomenon; to date, the evidence for its operation in man has been limited and has been confronted by considerable logistical challenges. Animal and translational models have incriminated a disturbed gut microbiota in a number of CNS disorders, including Parkinson's disease; data from human studies is scanty. While a theoretical basis can be developed for the use of microbiota-directed therapies in neurodegenerative disorders, support is yet to come from high-quality clinical trials. In theory, a role for the microbiota-gut-brain axis is highly plausible; clinical confirmation is awaited.

  6. Large deviations in the presence of cooperativity and slow dynamics

    Science.gov (United States)

    Whitelam, Stephen

    2018-06-01

    We study simple models of intermittency, involving switching between two states, within the dynamical large-deviation formalism. Singularities appear in the formalism when switching is cooperative or when its basic time scale diverges. In the first case the unbiased trajectory distribution undergoes a symmetry breaking, leading to a change in shape of the large-deviation rate function for a particular dynamical observable. In the second case the symmetry of the unbiased trajectory distribution remains unbroken. Comparison of these models suggests that singularities of the dynamical large-deviation formalism can signal the dynamical equivalent of an equilibrium phase transition but do not necessarily do so.

  7. Nonparaxial propagation of Lorentz-Gauss beams in uniaxial crystal orthogonal to the optical axis.

    Science.gov (United States)

    Wang, Xun; Liu, Zhirong; Zhao, Daomu

    2014-04-01

    Analytical expressions for the three components of nonparaxial propagation of a polarized Lorentz-Gauss beam in uniaxial crystal orthogonal to the optical axis are derived and used to investigate its propagation properties in uniaxial crystal. The influences of the initial beam parameters and the parameters of the uniaxial crystal on the evolution of the beam-intensity distribution in the uniaxial crystal are examined in detail. Results show that the statistical properties of a nonparaxial Lorentz-Gauss beam in a uniaxial crystal orthogonal to the optical axis are closely determined by the initial beam's parameters and the parameters of the crystal: the beam waist sizes-w(0), w(0x), and w(0y)-not only affect the size and shape of the beam profile in uniaxial crystal but also determine the nonparaxial effect of a Lorentz-Gauss beam; the beam profile of a Lorentz-Gauss beam in uniaxial crystal is elongated in the x or y direction, which is determined by the ratio of the extraordinary refractive index to the ordinary refractive index; with increasing deviation of the ratio from unity, the extension of the beam profile augments. The results indicate that uniaxial crystal provides an effective and convenient method for modulating the Lorentz-Gauss beams. Our results may be valuable in some fields, such as optical trapping and nonlinear optics, where a light beam with a special profile and polarization is required.

  8. A psychology of the human brain-gut-microbiome axis.

    Science.gov (United States)

    Allen, Andrew P; Dinan, Timothy G; Clarke, Gerard; Cryan, John F

    2017-04-01

    In recent years, we have seen increasing research within neuroscience and biopsychology on the interactions between the brain, the gastrointestinal tract, the bacteria within the gastrointestinal tract, and the bidirectional relationship between these systems: the brain-gut-microbiome axis. Although research has demonstrated that the gut microbiota can impact upon cognition and a variety of stress-related behaviours, including those relevant to anxiety and depression, we still do not know how this occurs. A deeper understanding of how psychological development as well as social and cultural factors impact upon the brain-gut-microbiome axis will contextualise the role of the axis in humans and inform psychological interventions that improve health within the brain-gut-microbiome axis. Interventions ostensibly aimed at ameliorating disorders in one part of the brain-gut-microbiome axis (e.g., psychotherapy for depression) may nonetheless impact upon other parts of the axis (e.g., microbiome composition and function), and functional gastrointestinal disorders such as irritable bowel syndrome represent a disorder of the axis, rather than an isolated problem either of psychology or of gastrointestinal function. The discipline of psychology needs to be cognisant of these interactions and can help to inform the future research agenda in this emerging field of research. In this review, we outline the role psychology has to play in understanding the brain-gut-microbiome axis, with a focus on human psychology and the use of research in laboratory animals to model human psychology.

  9. A psychology of the human brain–gut–microbiome axis

    Science.gov (United States)

    Allen, Andrew P.; Dinan, Timothy G.; Clarke, Gerard

    2017-01-01

    Abstract In recent years, we have seen increasing research within neuroscience and biopsychology on the interactions between the brain, the gastrointestinal tract, the bacteria within the gastrointestinal tract, and the bidirectional relationship between these systems: the brain–gut–microbiome axis. Although research has demonstrated that the gut microbiota can impact upon cognition and a variety of stress‐related behaviours, including those relevant to anxiety and depression, we still do not know how this occurs. A deeper understanding of how psychological development as well as social and cultural factors impact upon the brain–gut–microbiome axis will contextualise the role of the axis in humans and inform psychological interventions that improve health within the brain–gut–microbiome axis. Interventions ostensibly aimed at ameliorating disorders in one part of the brain–gut–microbiome axis (e.g., psychotherapy for depression) may nonetheless impact upon other parts of the axis (e.g., microbiome composition and function), and functional gastrointestinal disorders such as irritable bowel syndrome represent a disorder of the axis, rather than an isolated problem either of psychology or of gastrointestinal function. The discipline of psychology needs to be cognisant of these interactions and can help to inform the future research agenda in this emerging field of research. In this review, we outline the role psychology has to play in understanding the brain–gut–microbiome axis, with a focus on human psychology and the use of research in laboratory animals to model human psychology. PMID:28804508

  10. New strict left bundle branch block criteria reflect left ventricular activation differences

    DEFF Research Database (Denmark)

    Emerek, Kasper Janus Grønn; Risum, Niels; Hjortshøj, Søren Pihlkjær

    2015-01-01

    AIMS: Pacing lead electrical delays and strict left bundle branch block (LBBB) criteria were assessed against cardiac resynchronization therapy (CRT) outcome. METHODS: Forty-nine patients with LBBB and QRS duration >130 milliseconds underwent CRT-implantation. Sensed right ventricular to left ven....... CONCLUSION: Interventricular electrical delay predicts left ventricular remodeling after CRT and new, strict ECG criteria of LBBB are superior in predicting remodeling.......AIMS: Pacing lead electrical delays and strict left bundle branch block (LBBB) criteria were assessed against cardiac resynchronization therapy (CRT) outcome. METHODS: Forty-nine patients with LBBB and QRS duration >130 milliseconds underwent CRT-implantation. Sensed right ventricular to left...... ventricular electrical delay (RV-LV-IED) was measured. Response to CRT was defined as ≥15% decrease in left ventricular end-systolic volume. RESULTS: Eighteen of 20 (90%) patients with non-ischemic dilated cardiomyopathy (DCM) and 18 of 29 (62%) with ischemic heart disease (IHD) responded to CRT, p

  11. Effects of an Off-Axis Pivoting Elliptical Training Program on Gait Function in Persons With Spastic Cerebral Palsy: A Preliminary Study.

    Science.gov (United States)

    Tsai, Liang-Ching; Ren, Yupeng; Gaebler-Spira, Deborah J; Revivo, Gadi A; Zhang, Li-Qun

    2017-07-01

    This preliminary study examined the effects of off-axis elliptical training on reducing transverse-plane gait deviations and improving gait function in 8 individuals with cerebral palsy (CP) (15.5 ± 4.1 years) who completed an training program using a custom-made elliptical trainer that allows transverse-plane pivoting of the footplates during exercise. Lower-extremity off-axis control during elliptical exercise was evaluated by quantifying the root-mean-square and maximal angular displacement of the footplate pivoting angle. Lower-extremity pivoting strength was assessed. Gait function and balance were evaluated using 10-m walk test, 6-minute-walk test, and Pediatric Balance Scale. Toe-in angles during gait were quantified. Participants with CP demonstrated a significant decrease in the pivoting angle (root mean square and maximal angular displacement; effect size, 1.00-2.00) and increase in the lower-extremity pivoting strength (effect size = 0.91-1.09) after training. Reduced 10-m walk test time (11.9 ± 3.7 seconds vs. 10.8 ± 3.0 seconds; P = 0.004; effect size = 1.46), increased Pediatric Balance Scale score (43.6 ± 12.9 vs. 45.6 ± 10.8; P = 0.042; effect size = 0.79), and decreased toe-in angle (3.7 ± 10.5 degrees vs. 0.7 ± 11.7 degrees; P = 0.011; effect size = 1.22) were observed after training. We present an intervention to challenge lower-extremity off-axis control during a weight-bearing and functional activity for individuals with CP. Our preliminary findings suggest that this intervention was effective in enhancing off-axis control, gait function, and balance and reducing in-toeing gait in persons with CP.

  12. Statistical properties of the deviations of f 0 F 2 from monthly medians

    Directory of Open Access Journals (Sweden)

    Y. Tulunay

    2002-06-01

    Full Text Available The deviations of hourly f 0 F 2 from monthly medians for 20 stations in Europe during the period 1958-1998 are studied. Spectral analysis is used to show that, both for original data (for each hour and for the deviations from monthly medians, the deterministic components are the harmonics of 11 years (solar cycle, 1 year and its harmonics, 27 days and 12 h 50.49 m (2nd harmonic of lunar rotation period L 2 periodicities. Using histograms for one year samples, it is shown that the deviations from monthly medians are nearly zero mean (mean < 0.5 and approximately Gaussian (relative difference range between %10 to %20 and their standard deviations are larger for daylight hours (in the range 5-7. It is shown that the amplitude distribution of the positive and negative deviations is nearly symmetrical at night hours, but asymmetrical for day hours. The positive and negative deviations are then studied separately and it is observed that the positive deviations are nearly independent of R12 except for high latitudes, but negative deviations are modulated by R12 . The 90% confidence interval for negative deviations for each station and each hour is computed as a linear model in terms of R12. After correction for local time, it is shown that for all hours the confidence intervals increase with latitude but decrease above 60N. Long-term trend analysis showed that there is an increase in the amplitude of positive deviations from monthly means irrespective of the solar conditions. Using spectral analysis it is also shown that the seasonal dependency of negative deviations is more accentuated than the seasonal dependency of positive deviations especially at low latitudes. In certain stations, it is also observed that the 4th harmonic of 1 year corresponding to a periodicity of 3 months, which is missing in f 0 F 2 data, appears in the spectra of negative variations.

  13. Assessment of dedicated low-dose cardiac micro-CT reconstruction algorithms using the left ventricular volume of small rodents as a performance measure

    Energy Technology Data Exchange (ETDEWEB)

    Maier, Joscha, E-mail: joscha.maier@dkfz.de [Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Sawall, Stefan; Kachelrieß, Marc [Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany and Institute of Medical Physics, University of Erlangen–Nürnberg, 91052 Erlangen (Germany)

    2014-05-15

    HDTV algorithm shows the best performance. At 50 mGy, the deviation from the reference obtained at 500 mGy were less than 4%. Also the LDPC algorithm provides reasonable results with deviation less than 10% at 50 mGy while PCF and MKB reconstruction show larger deviations even at higher dose levels. Conclusions: LDPC and HDTV increase CNR and allow for quantitative evaluations even at dose levels as low as 50 mGy. The left ventricular volumes exemplarily illustrate that cardiac parameters can be accurately estimated at lowest dose levels if sophisticated algorithms are used. This allows to reduce dose by a factor of 10 compared to today's gold standard and opens new options for longitudinal studies of the heart.

  14. Assessment of dedicated low-dose cardiac micro-CT reconstruction algorithms using the left ventricular volume of small rodents as a performance measure

    International Nuclear Information System (INIS)

    Maier, Joscha; Sawall, Stefan; Kachelrieß, Marc

    2014-01-01

    HDTV algorithm shows the best performance. At 50 mGy, the deviation from the reference obtained at 500 mGy were less than 4%. Also the LDPC algorithm provides reasonable results with deviation less than 10% at 50 mGy while PCF and MKB reconstruction show larger deviations even at higher dose levels. Conclusions: LDPC and HDTV increase CNR and allow for quantitative evaluations even at dose levels as low as 50 mGy. The left ventricular volumes exemplarily illustrate that cardiac parameters can be accurately estimated at lowest dose levels if sophisticated algorithms are used. This allows to reduce dose by a factor of 10 compared to today's gold standard and opens new options for longitudinal studies of the heart

  15. Assessment of dedicated low-dose cardiac micro-CT reconstruction algorithms using the left ventricular volume of small rodents as a performance measure.

    Science.gov (United States)

    Maier, Joscha; Sawall, Stefan; Kachelrieß, Marc

    2014-05-01

    best performance. At 50 mGy, the deviation from the reference obtained at 500 mGy were less than 4%. Also the LDPC algorithm provides reasonable results with deviation less than 10% at 50 mGy while PCF and MKB reconstruction show larger deviations even at higher dose levels. LDPC and HDTV increase CNR and allow for quantitative evaluations even at dose levels as low as 50 mGy. The left ventricular volumes exemplarily illustrate that cardiac parameters can be accurately estimated at lowest dose levels if sophisticated algorithms are used. This allows to reduce dose by a factor of 10 compared to today's gold standard and opens new options for longitudinal studies of the heart.

  16. VAR Portfolio Optimal: Perbandingan Antara Metode Markowitz Dan Mean Absolute Deviation

    OpenAIRE

    Sartono, R. Agus; Setiawan, Arie Andika

    2006-01-01

    Portfolio selection method which have been introduced by Harry Markowitz (1952) used variance or deviation standard as a measure of risk. Kanno and Yamazaki (1991) introduced another method and used mean absolute deviation as a measure of risk instead of variance. The Value-at Risk (VaR) is a relatively new method to capitalized risk that been used by financial institutions. The aim of this research is compare between mean variance and mean absolute deviation of two portfolios. Next, we attem...

  17. Helical axis stellarator equilibrium model

    International Nuclear Information System (INIS)

    Koniges, A.E.; Johnson, J.L.

    1985-02-01

    An asymptotic model is developed to study MHD equilibria in toroidal systems with a helical magnetic axis. Using a characteristic coordinate system based on the vacuum field lines, the equilibrium problem is reduced to a two-dimensional generalized partial differential equation of the Grad-Shafranov type. A stellarator-expansion free-boundary equilibrium code is modified to solve the helical-axis equations. The expansion model is used to predict the equilibrium properties of Asperators NP-3 and NP-4. Numerically determined flux surfaces, magnetic well, transform, and shear are presented. The equilibria show a toroidal Shafranov shift

  18. The hypothalamo-pituitary-adrenal axis in major affective disorder

    DEFF Research Database (Denmark)

    Christensen, M V; Kessing, L V

    2001-01-01

    disorder. The HPA axis is a complex neuroendocrine network with multiple integrated levels of control, and it is likely that the dysregulation involves abnormalities at several sites within the axis. At present, it is not clear whether the abnormalities are related to the affective episodes only......This paper reviews studies of the hypothalamo-pituitary-adrenal (HPA)-axis activity in patients with affective disorders. It is concluded that, despite methodological drawbacks in most studies, dysregulation of the HPA axis seems to be a consistent finding in a proportion of patients with affective...... or to the disorder itself. There is a need for prospective studies of larger samples of patients to be followed during successive affective episodes with a combination of measurements of the HPA-axis activity and brain imaging....

  19. Left atrial systolic force in hypertensive patients with left ventricular hypertrophy: the LIFE study

    DEFF Research Database (Denmark)

    Chinali, M.; Simone, G. de; Wachtell, K.

    2008-01-01

    In hypertensive patients without prevalent cardiovascular disease, enhanced left atrial systolic force is associated with left ventricular hypertrophy and increased preload. It also predicts cardiovascular events in a population with high prevalence of obesity. Relations between left atrial...... systolic force and left ventricular geometry and function have not been investigated in high-risk hypertrophic hypertensive patients. Participants in the Losartan Intervention For Endpoint reduction in hypertension echocardiography substudy without prevalent cardiovascular disease or atrial fibrillation (n...... = 567) underwent standard Doppler echocardiography. Left atrial systolic force was obtained from the mitral orifice area and Doppler mitral peak A velocity. Patients were divided into groups with normal or increased left atrial systolic force (>14.33 kdyn). Left atrial systolic force was high in 297...

  20. Large deviation function for a driven underdamped particle in a periodic potential

    Science.gov (United States)

    Fischer, Lukas P.; Pietzonka, Patrick; Seifert, Udo

    2018-02-01

    Employing large deviation theory, we explore current fluctuations of underdamped Brownian motion for the paradigmatic example of a single particle in a one-dimensional periodic potential. Two different approaches to the large deviation function of the particle current are presented. First, we derive an explicit expression for the large deviation functional of the empirical phase space density, which replaces the level 2.5 functional used for overdamped dynamics. Using this approach, we obtain several bounds on the large deviation function of the particle current. We compare these to bounds for overdamped dynamics that have recently been derived, motivated by the thermodynamic uncertainty relation. Second, we provide a method to calculate the large deviation function via the cumulant generating function. We use this method to assess the tightness of the bounds in a numerical case study for a cosine potential.

  1. Automated Slicing for a Multi-Axis Metal Deposition System (Preprint)

    Science.gov (United States)

    2006-09-01

    experimented with different materials like H13 tool steel to build the part. Following the same slicing and scanning toolpath result, there is a geometric...and analysis tool -centroidal axis. Similar to medial axis, it contains geometry and topological information but is significantly computationally...geometry reasoning and analysis tool -centroidal axis. Similar to medial axis, it contains geometry and topological information but is significantly

  2. Proper time axis of a closed relativistic system

    International Nuclear Information System (INIS)

    Chernikov, N.A.; Fadeev, N.G.; Shavokhina, N.S.

    1997-01-01

    The definition of a proper time axis of a closed relativistic system of colliding particles is given. The solution of the proper time axis problem is presented. If the light velocity c equals the imaginary unit i, then in the case of a plane motion of the system the problem about the proper time axis turns out to be equivalent to the known in engineering mechanics problem about the reduction of any system of forces, applied to a rigid body, to the dynamic screw. In the general case, when c=i, the problem about the proper time axis turns out to be equivalent to the problem about the reduction to the dynamic screw of a system of forces, applied to a rigid body in a four-dimensional Euclidean space

  3. Multi-slice CT (MSCT) in cardiac function imaging: threshold-value-supported 3D volume reconstructions to determine the left ventricular ejection fraction in comparison to MRI

    International Nuclear Information System (INIS)

    Ehrhard, K.; Oberholzer, K.; Gast, K.; Mildenberger, P.; Kreitner, K.F.; Thelen, M.

    2002-01-01

    Purpose: To assess MSCT of the heart to determining left ventricular ejection fraction (EF) based on threshold-value-supported 3D volume reconstructions compared to MRI. Methods: Cardiac MSCT was performed in 7 patients. Images were reconstructed during end-systolic and end-diastolic phases of the cardiac cycle and transformed to 3D volumes to determine end-systolic (ESV) and end-diastolic volume (EDV) by using different lower threshold values: besides fixed lower threshold values, identical for each image sequence, individual lower threshold values dependent on contrast enhancement of the left ventricle were applied. The latter represent the mean value calculated by combining the average CT-density of the myocardium and the contrast-enhanced blood in the left ventricle. The EF derived from ESV and EDV. Results: The best correlation with MR imaging was obtained for ESV and EDV by using the individual lower threshold values for the respective sequence. The correlation coefficient for ESV was 0.95 and for EDV it was 0.93. On average, the ESV was overestimated by 3.72 ml, while the ESD was underestimated by 2.85 ml. The respective standard deviation for the ESV was 14,87 ml, for the EDV it was 26.83 ml. On average, the EF was underestimated by 3.57% with a standard deviation of 9.43% and a correlation coefficient of 0.83 in comparison to MRI. Conclusion: The threshold-value-supported 3D volume reconstruction of the left ventricle represents a good method to determine the left ventricular function parameters. Due to the differences in the contrast enhancement, the use of an individual lower threshold value for every image sequence is of particular importance. (orig.) [de

  4. Is Kantian ethics left defenseless in the face of evil?

    Directory of Open Access Journals (Sweden)

    Matthew Stapleton

    2002-01-01

    Full Text Available Within this essay the question of whether Kantian ethics is left defenseless in the face of evil is unfolded. Some thinkers claim that it is not advisable to rigorously adhere to the categorical imperative. That is to say, it is prudent only to follow the categorical imperative, acting in such a way that you may will that the maxim of your actions becomes a universal law, when one is dealing with other ethical beings. However, when dealing with evil, it is claimed that we should develop other special principles that allow for consequences favorable to the ethical party. This essay takes exception with this claim, demonstrating that for Kant such a problem would not have even appeared. Furthermore, this essay argues that to deviate from the moral principle does damage to the truth and humanity as a whole.

  5. Evolutionary implications of genetic code deviations

    International Nuclear Information System (INIS)

    Chela Flores, J.

    1986-07-01

    By extending the standard genetic code into a temperature dependent regime, we propose a train of molecular events leading to alternative coding. The first few examples of these deviations have already been reported in some ciliated protozoans and Gram positive bacteria. A possible range of further alternative coding, still within the context of universality, is pointed out. (author)

  6. Observations of super early left ventricular remodeling experimental myocardial infarction

    International Nuclear Information System (INIS)

    Zhang, C.G.; Jin, J.H.; Zhao, X.B.; Kang, C.S.; Liang, F.Y.; Yin, Z.M.; Liu, G.F.; Li, S.J.; Li, X.F.; Hu, G.; Qin, D.Z.; Song, L.Z.

    2004-01-01

    , the animals were euthanized and their hearts were examined for pathology. SPECT reconstruction parameters: Filter; Butterworth; cutoff 0.35 and order 5: filtered backprojection. Images: short axis, horizontal and vertical long axis. Data analysis: Quantitative analysis: Quantitative Gated SPECT (QGS) software was used for calculating the end diastolic volume (EDV), end systolic volume (ESV) and ejection fraction (EF) Data from 16 animals was used. Qualitative analysis was used to assess shape, size of entire left ventricle, and wall motion which data was from 15 dogs. Echocardiography: HP5500 color Doppler ultrasonography diagnosis system with 12 MHz was used for echocardiography. EDV, ESV and EF were calculated by Simpson's method. Statistics analysis: SPSS statistics software was used for all quantitative data analysis. Results: A typical defect with complete absence of wall motion was found at the apex in all dogs (GA and GB) after LAD ligation, beginning with the first acquisition. Post-operatively, EDV and ESV significantly increased compared with pre-operation values. EF significantly decreased post-operatively. The table below shows quantitative data obtained at the earliest time after ligation. EDV and ESV continued to increase during the 6 hours post-operatively, while EF was just the opposite, decreasing with time. Using continuous gated myocardial imaging, reperfusion was found in 10 dogs (62.5%) on the apex area at 1-3 hours after the defect was originally visualized, when a thinning wall could be seen on the apex defect area. By visual analysis we found structural characteristics of left ventricular remodeling, including infarct expansion with thinning (14/15 animals), lengthening (15/15), regional enlargement (9/15) and distortion (11/15). We also found remodeling of non-infarcted myocardium, including thickening (12/15) and lengthening (13/15) as well as global distortion of shape (15/15) and global ventricular dilatation (14/15). Statistical analysis

  7. Innovative approach to computer-aided design of horizontal axis wind turbine blades

    Directory of Open Access Journals (Sweden)

    Seyed Farhad Hosseini

    2017-04-01

    Full Text Available The design of horizontal axis wind turbine (HAWT blades involves several geometric complexities. As a result, the modeling of these blades by commercial computer-aided design (CAD software is not easily accomplished. In the present paper, the HAWT blade is divided into structural and aerodynamic surfaces with a G1 continuity imposed on their connecting region. The widely used method of skinning is employed throughout the current work for surface approximation. In addition, to ensure the compatibility of section curves, a novel approach is developed based on the redistribution of input airfoil points. In order to evaluate deviation errors, the Hausdorff metric is used. The fairness of surfaces is quantitatively assessed using the standard strain energy method. The above-mentioned algorithms are successfully integrated into a MATLAB program so as to enhance further optimization applications. The final surfaces created by the procedure developed during the present study can be exported using the IGES standard file format and directly interpreted by commercial CAD and FE software.

  8. FAMILY HISTORY STUDY OF THE FAMILIAL COAGGREGATION OF BORDERLINE PERSONALITY DISORDER WITH AXIS I AND NON-BORDERLINE DRAMATIC CLUSTER AXIS II DISORDERS

    OpenAIRE

    Zanarini, Mary C.; Barison, Leah K.; Frankenburg, Frances R.; Reich, D. Bradford; Hudson, James I.

    2009-01-01

    The purpose of this study was to assess the familial coaggregation of borderline personality disorder (BPD) with a full array of axis I disorders and four axis II disorders (antisocial personality disorder, histrionic personality disorder, narcissistic personality disorder, and sadistic personality disorder) in the first-degree relatives of borderline probands and axis II comparison subjects. Four hundred and forty-five inpatients were interviewed about familial psychopathology using the Revi...

  9. The History of Left Septal Fascicular Block: Chronological Considerations of a Reality Yet to be Universally Accepted

    Directory of Open Access Journals (Sweden)

    Andres Ricardo Perez Riera

    2008-04-01

    Full Text Available There are several papers in literature that prove in a conclusive and incontestable way, that the left branch of the His bundle, in most instances (85% of the cases splits into three fascicles of variable morphological pattern, and not into two: left anterior fascicle (LAF, left posterior fascicle (LPF, and left septal fascicle (LSF. The abovementioned papers have anatomical, histological, anatomo-pathological, electrocardiographic, and vectocardiographic, body surface potential mapping or ECG potential mapping and electrophysiological foundation. Additionally, the mentioned papers have been performed both in animal models (dogs and in the human heart. Several clinical papers have shown that the left septal fascicular block (LSFB may occur intermittently or transitorily as a consequence of a temporary dromotropic alteration, constituting an aberrant ventricular conduction, rate-dependent or by the application of atrial extra-stimuli, or naturally during the acute phase of infarction when this involves the anterior descending artery, before the septal perforating artery that supplies the central portion of the septum, where the mentioned LSF runs. The ECG/VCG manifestation of LSFB consists in anterior shift of electromotive forces, known as Prominent Anterior Forces (PAF, which can hardly be diagnosed in the clinical absence of other causes capable of causing PAF, such as the normal variant by counterclockwise rotation of the heart on its longitudinal axis, in right ventricular enlargement, in the dorsal or lateral infarction of the new nomenclature, in type-A WPW, in CRBBB, and others. In this historical manuscript, we review in a sequential fashion, the main findings that confirmed the unequivocal existence of this unjustifiably "forgotten" dromotropic disorder. In the developed countries, its most important cause is coronary insufficiency, particularly the proximal involvement of the left anterior descending coronary artery, and in Latin

  10. Evaluation of early systolic flow pattern in left ventricle by tagging cine MRI in normal volunteers

    International Nuclear Information System (INIS)

    Sakakura, Kazuyoshi; Anno, Naoko; Kondo, Takeshi

    1992-01-01

    The tagging method is a new technique, which permits to apply discretionary lines (tags) on MR images. To evaluate intra left ventricular (LV) flow pattern, we performed ECG-gated gradient field echo cine MRI using tagging method in five normal male volunteers, aged 22-42 years. The horizontal long axis view of LV was imaged by multiphasic field echo pulse sequence. The three parallel tags (basal, middle and apical portion) were established on the horizontal long axis view of LV just after the triggered QRS waves. And the initial two images (70 ms and 120 ms after the triggered QRS waves) were analyzed. On the two tags (middle and apical portion) of these three tags, we measured the distance of displacement of the tags on three points (the near site of IVS, middle portion and the near site of free wall) respectively. At 70 ms after the trigger point, the only tagged blood at the near site of free wall flowed toward the apex. At 120 ms after the trigger point, all the tagged blood flowed toward the outflow tract of LV. And the maximum blood flow velocity was observed at the near site of IVS on middle portion of LV (166.0 mm/s). These results coincided with earlier studies by Doppler echocardiography. But we could not observe intra LV blood flow patterns throughout one cardiac cycle in this pulse sequence, because the tags had flowed out from LV and had become unclear due to spin relaxation and mixing. We concluded that the tagging method was useful to evaluate intra left ventricular blood flow patterns in early systolic phase. (author)

  11. Repair of aorto-left ventricular tunnel arising from the left sinus of valsalva.

    Science.gov (United States)

    Nezafati, Mohammad Hassan; Maleki, Mahmood Hosseinzadeh; Javan, Hadi; Zirak, Nahid

    2010-05-01

    Aortico-left ventricular tunnel (ALVT) is a rare congenital cardiac defect that bypasses the aortic valve via a para-valvular connection from the left ventricle to the aorta. In most cases, the tunnel arises from the right aortic sinus. In this case report, we are presenting a case of ALVT, of which the aortic orifice arose from the left aortic sinus, requiring special attention to avoid the left coronary artery injury at the time of surgical repair.

  12. Ankle-foot orthosis bending axis influences running mechanics.

    Science.gov (United States)

    Russell Esposito, Elizabeth; Ranz, Ellyn C; Schmidtbauer, Kelly A; Neptune, Richard R; Wilken, Jason M

    2017-07-01

    Passive-dynamic ankle-foot orthoses (AFOs) are commonly prescribed to improve locomotion for people with lower limb musculoskeletal weakness. The clinical prescription and design process are typically qualitative and based on observational assessment and experience. Prior work examining the effect of AFO design characteristics generally excludes higher impact activities such as running, providing clinicians and researchers limited information to guide the development of objective prescription guidelines. The proximal location of the bending axis may directly influence energy storage and return and resulting running mechanics. The purpose of this study was to determine if the location of an AFO's bending axis influences running mechanics. Marker and force data were recorded as 12 participants with lower extremity weakness ran overground while wearing a passive-dynamic AFO with posterior struts manufactured with central (middle) and off-centered (high and low) bending axes. Lower extremity joint angles, moments, powers, and ground reaction forces were calculated and compared between limbs and across bending axis conditions. Bending axis produced relatively small but significant changes. Ankle range of motion increased as the bending axis shifted distally (pbenefits during running, although individual preference and physical ability should also be considered. Published by Elsevier B.V.

  13. Self-starting aerodynamics analysis of vertical axis wind turbine

    Directory of Open Access Journals (Sweden)

    Jianyang Zhu

    2015-12-01

    Full Text Available Vertical axis wind turbine is a special type of wind-force electric generator which is capable of working in the complicated wind environment. The self-starting aerodynamics is one of the most important considerations for this kind of turbine. This article aims at providing a systematic synthesis on the self-starting aerodynamic characteristics of vertical axis wind turbine based on the numerical analysis approach. First, the physical model of vertical axis wind turbine and its parameter definitions are presented. Secondary, the interaction model between the vertical axis wind turbine and fluid is developed by using the weak coupling approach; the numerical data of this model are then compared with the wind tunnel experimental data to show its feasibility. Third, the effects of solidity and fixed pitch angle on the self-starting aerodynamic characteristics of the vertical axis wind turbine are analyzed systematically. Finally, the quantification effects of the solidity and fixed pitch angle on the self-starting performance of the turbine can be obtained. The analysis in this study will provide straightforward physical insight into the self-starting aerodynamic characteristics of vertical axis wind turbine.

  14. Design and optimize of 3-axis filament winding machine

    Science.gov (United States)

    Quanjin, Ma; Rejab, M. R. M.; Idris, M. S.; Bachtiar, B.; Siregar, J. P.; Harith, M. N.

    2017-10-01

    Filament winding technique is developed as the primary process for composite cylindrical structures fabrication at low cost. Fibres are wound on a rotating mandrel by a filament winding machine where resin impregnated fibres pass through a pay-out eye. This paper aims to develop and optimize a 3-axis, lightweight, practical, efficient, portable filament winding machine to satisfy the customer demand, which can fabricate pipes and round shape cylinders with resins. There are 3 main units on the 3-axis filament winding machine, which are the rotary unit, the delivery unit and control system unit. Comparison with previous existing filament winding machines in the factory, it has 3 degrees of freedom and can fabricate more complex shape specimens based on the mandrel shape and particular control system. The machine has been designed and fabricated on 3 axes movements with control system. The x-axis is for movement of the carriage, the y-axis is the rotation of mandrel and the z-axis is the movement of the pay-out eye. Cylindrical specimens with different dimensions and winding angles were produced. 3-axis automated filament winding machine has been successfully designed with simple control system.

  15. Shot H3837: Darht's First Dual-Axis Explosive Experiment

    Science.gov (United States)

    Mendez, Jacob; McNeil, Wendy Vogan; Harsh, James; Hull, Lawrence

    2011-06-01

    Test H3837 was the first explosive shot performed in front of both flash x-ray axes at the Los Alamos Dual Axis Radiographic HydroTest (DARHT) facility. Executed in November 2009, the shot was an explosively-driven metal flyer plate in a series of experiments designed to explore equation-of-state properties of shocked materials. Imaging the initial shock wave traveling through the flyer plate, DARHT Axis II captured the range of motion from the shock front emergence in the flyer to breakout at the free surface; the Axis I pulse provided a perpendicular perspective of the shot at a time coinciding with the third pulse of Axis II. Since the days of the Manhattan Project, penetrating radiography with multiple frames from different viewing angles has remained a high-profile goal at the Laboratory. H3837 is merely the beginning of a bright future for two-axis penetrating radiography.

  16. Off-axis vortex breakdown in a shallow whirlpool.

    Science.gov (United States)

    Herrada, Miguel A; Shtern, Vladimir N; López-Herrera, José María

    2013-06-01

    The off-axis emergence of vortex breakdown (VB) is revealed. The steady axisymmetric flow in a vertical sealed cylinder, which is partially filled with water and the rest is filled with air, is driven by the rotating bottom disk. The numerical simulations show that VB can emerge away from the rotation axis, interface, and walls. As the rotation intensifies, VB first develops in the water region. If the water height is less (larger) than nearly one half of the cylinder radius, VB emerges off (on) the axis. As the rotation further increases, the off-axis VB ring touches the interface and then a thin countercirculation layer develops in the air flow above the water VB domain. This two-fluid VB ring shrinks (it even disappears in a very shallow whirlpool) as the interface approaches the bottom disk.

  17. Rhythmic and melodic deviations in musical sequences recruit different cortical areas for mismatch detection.

    Science.gov (United States)

    Lappe, Claudia; Steinsträter, Olaf; Pantev, Christo

    2013-01-01

    The mismatch negativity (MMN), an event-related potential (ERP) representing the violation of an acoustic regularity, is considered as a pre-attentive change detection mechanism at the sensory level on the one hand and as a prediction error signal on the other hand, suggesting that bottom-up as well as top-down processes are involved in its generation. Rhythmic and melodic deviations within a musical sequence elicit a MMN in musically trained subjects, indicating that acquired musical expertise leads to better discrimination accuracy of musical material and better predictions about upcoming musical events. Expectation violations to musical material could therefore recruit neural generators that reflect top-down processes that are based on musical knowledge. We describe the neural generators of the musical MMN for rhythmic and melodic material after a short-term sensorimotor-auditory (SA) training. We compare the localization of musical MMN data from two previous MEG studies by applying beamformer analysis. One study focused on the melodic harmonic progression whereas the other study focused on rhythmic progression. The MMN to melodic deviations revealed significant right hemispheric neural activation in the superior temporal gyrus (STG), inferior frontal cortex (IFC), and the superior frontal (SFG) and orbitofrontal (OFG) gyri. IFC and SFG activation was also observed in the left hemisphere. In contrast, beamformer analysis of the data from the rhythm study revealed bilateral activation within the vicinity of auditory cortices and in the inferior parietal lobule (IPL), an area that has recently been implied in temporal processing. We conclude that different cortical networks are activated in the analysis of the temporal and the melodic content of musical material, and discuss these networks in the context of the dual-pathway model of auditory processing.

  18. Rhythmic and melodic deviations in musical sequences recruit different cortical areas for mismatch detection

    Directory of Open Access Journals (Sweden)

    Claudia eLappe

    2013-06-01

    Full Text Available The mismatch negativity (MMN, an event-related potential (ERP representing the violation of an acoustic regularity, is considered as a pre-attentive change detection mechanism at the sensory level on the one hand and as a prediction error signal on the other hand, suggesting that bottom-up as well as top-down processes are involved in its generation. Rhythmic and melodic deviations within a musical sequence elicit a mismatch negativity in musically trained subjects, indicating that acquired musical expertise leads to better discrimination accuracy of musical material and better predictions about upcoming musical events. Expectation violations to musical material could therefore recruit neural generators that reflect top-down processes that are based on musical knowledge.We describe the neural generators of the musical MMN for rhythmic and melodic material after a short-term sensorimotor-auditory training. We compare the localization of musical MMN data from two previous MEG studies by applying beamformer analysis. One study focused on the melodic harmonic progression whereas the other study focused on rhythmic progression. The MMN to melodic deviations revealed significant right hemispheric neural activation in the superior temporal gyrus (STG, inferior frontal cortex (IFC, and the superior frontal (SFG and orbitofrontal (OFG gyri. IFC and SFG activation was also observed in the left hemisphere. In contrast, beamformer analysis of the data from the rhythm study revealed bilatral activation within the vicinity of auditory cortices and in the inferior parietal lobule, an area that has recently been implied in temporal processing. We conclude that different cortical networks are activated in the analysis of the temporal and the melodic content of musical material, and discuss these networks in the context of the the dual-pathway model of auditory processing.

  19. What's Left of the Left-Right Dimension? Why the Economic Policy Positions of Europeans Do Not Fit the Left-Right Dimension.

    Science.gov (United States)

    Otjes, Simon

    2018-01-01

    In political science the economic left-right dimension plays a central role. A growing body of evidence shows that the economic policy preferences of a large segment of citizens do not scale sufficiently. Using Mokken scale analysis, this study determines the causes of this phenomenon. Differences in the extent to which the economic policy preferences of citizens fit the left-right dimension can be explained in terms of the interaction between individual level and political system-level variables: citizens who spend more attention to politicians with views that conform to the left-right dimension, have views that conform to the left-right dimension. There is also a role for the legacy of communist dictatorship: citizens who were socialised in democratic countries have views that fit the left-right dimension better than those socialised during communism.

  20. Full-field transmission-type angle-deviation optical microscope with reflectivity-height transformation.

    Science.gov (United States)

    Chiu, Ming-Hung; Tan, Chen-Tai; Tsai, Ming-Hung; Yang, Ya-Hsin

    2015-10-01

    This full-field transmission-type three-dimensional (3D) optical microscope is constructed based on the angle deviation method (ADM) and the algorithm of reflectivity-height transformation (RHT). The surface height is proportional to the deviation angle of light passing through the object. The angle deviation and surface height can be measured based on the reflectivity closed to the critical angle using a parallelogram prism and two CCDs.

  1. A course on large deviations with an introduction to Gibbs measures

    CERN Document Server

    Rassoul-Agha, Firas

    2015-01-01

    This is an introductory course on the methods of computing asymptotics of probabilities of rare events: the theory of large deviations. The book combines large deviation theory with basic statistical mechanics, namely Gibbs measures with their variational characterization and the phase transition of the Ising model, in a text intended for a one semester or quarter course. The book begins with a straightforward approach to the key ideas and results of large deviation theory in the context of independent identically distributed random variables. This includes Cramér's theorem, relative entropy, Sanov's theorem, process level large deviations, convex duality, and change of measure arguments. Dependence is introduced through the interactions potentials of equilibrium statistical mechanics. The phase transition of the Ising model is proved in two different ways: first in the classical way with the Peierls argument, Dobrushin's uniqueness condition, and correlation inequalities and then a second time through the ...

  2. Analysis on detection accuracy of binocular photoelectric instrument optical axis parallelism digital calibration instrument

    Science.gov (United States)

    Ying, Jia-ju; Yin, Jian-ling; Wu, Dong-sheng; Liu, Jie; Chen, Yu-dan

    2017-11-01

    Low-light level night vision device and thermal infrared imaging binocular photoelectric instrument are used widely. The maladjustment of binocular instrument ocular axises parallelism will cause the observer the symptom such as dizziness, nausea, when use for a long time. Binocular photoelectric equipment digital calibration instrument is developed for detecting ocular axises parallelism. And the quantitative value of optical axis deviation can be quantitatively measured. As a testing instrument, the precision must be much higher than the standard of test instrument. Analyzes the factors that influence the accuracy of detection. Factors exist in each testing process link which affect the precision of the detecting instrument. They can be divided into two categories, one category is factors which directly affect the position of reticle image, the other category is factors which affect the calculation the center of reticle image. And the Synthesize error is calculated out. And further distribute the errors reasonably to ensure the accuracy of calibration instruments.

  3. Anatomic relationship between left coronary artery and left atrium in patients undergoing atrial fibrillation ablation.

    Science.gov (United States)

    Anselmino, Matteo; Torri, Federica; Ferraris, Federico; Calò, Leonardo; Castagno, Davide; Gili, Sebastiano; Rovera, Chiara; Giustetto, Carla; Gaita, Fiorenzo

    2017-07-01

    Atrial fibrillation transcatheter ablation (TCA) is, within available atrial fibrillation rhythm control strategies, one of the most effective. To potentially improve ablation outcome in case of recurrent atrial fibrillation after a first procedure or in presence of structural myocardial disease, isolation of the pulmonary veins may be associated with extensive lesions within the left atrium. To avoid rare, but potentially life-threatening, complications, thorough knowledge and assessment of left atrium anatomy and its relation to structures in close proximity are, therefore, mandatory. Aim of the present study is to describe, by cardiac computed tomography, the anatomic relationship between aortic root, left coronary artery and left atrium in patients undergoing atrial fibrillation TCA. The cardiac computed tomography scan of 21 patients affected by atrial fibrillation was elaborated to segment left atrium, aortic root and left coronary artery from the surrounding structures and the following distances measured: left atrium and aortic root; left atrium roof and aortic root; left main coronary artery and left atrium; circumflex artery and left atrium appendage; and circumflex artery and mitral valve annulus. Above all, the median distance between left atrium and aortic root (1.9, 1.5-2.1 mm), and between circumflex artery and left atrium appendage ostium (3.0, 2.1-3.4 mm) were minimal (≤3 mm). None of measured distances significantly varied between patients presenting paroxysmal versus persistent atrial fibrillation. The anatomic relationship between left atrium and coronary arteries is extremely relevant when performing atrial fibrillation TCA by extensive lesions. Therefore, at least in the latter case, preablation imaging should be recommended to avoid rare, but potentially life-threatening, complications with the aim of an as well tolerated as possible procedure.

  4. Automated Assessment of Left Ventricular Function and Mass Using Heart Deformation Analysis: Initial Experience in 160 Older Adults.

    Science.gov (United States)

    Lin, Kai; Collins, Jeremy D; Lloyd-Jones, Donald M; Jolly, Marie-Pierre; Li, Debiao; Markl, Michael; Carr, James C

    2016-03-01

    To assess the performance of automated quantification of left ventricular function and mass based on heart deformation analysis (HDA) in asymptomatic older adults. This study complied with Health Insurance Portability and Accountability Act regulations. Following the approval of the institutional review board, 160 asymptomatic older participants were recruited for cardiac magnetic resonance imaging including two-dimensional cine images covering the entire left ventricle in short-axis view. Data analysis included the calculation of left ventricular ejection fraction (LVEF), left ventricular mass (LVM), and cardiac output (CO) using HDA and standard global cardiac function analysis (delineation of end-systolic and end-diastolic left ventricle epi- and endocardial borders). The agreement between methods was evaluated using intraclass correlation coefficient (ICC) and coefficient of variation (CoV). HDA had a shorter processing time than the standard method (1.5 ± 0.3 min/case vs. 5.8 ± 1.4 min/case, P HDA. There was a systemic bias toward lower LVEF (62.8% ± 8.3% vs. 69.3% ± 6.7%, P HDA compared to the standard technique. Conversely, HDA overestimated LVM (114.8 ± 30.1 g vs. 100.2 ± 29.0 g, P HDA has the potential to measure LVEF, CO, and LVM without the need for user interaction based on standard cardiac two-dimensional cine images. Copyright © 2015 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  5. Cell chirality: its origin and roles in left-right asymmetric development.

    Science.gov (United States)

    Inaki, Mikiko; Liu, Jingyang; Matsuno, Kenji

    2016-12-19

    An item is chiral if it cannot be superimposed on its mirror image. Most biological molecules are chiral. The homochirality of amino acids ensures that proteins are chiral, which is essential for their functions. Chirality also occurs at the whole-cell level, which was first studied mostly in ciliates, single-celled protozoans. Ciliates show chirality in their cortical structures, which is not determined by genetics, but by 'cortical inheritance'. These studies suggested that molecular chirality directs whole-cell chirality. Intriguingly, chirality in cellular structures and functions is also found in metazoans. In Drosophila, intrinsic cell chirality is observed in various left-right (LR) asymmetric tissues, and appears to be responsible for their LR asymmetric morphogenesis. In other invertebrates, such as snails and Caenorhabditis elegans, blastomere chirality is responsible for subsequent LR asymmetric development. Various cultured cells of vertebrates also show intrinsic chirality in their cellular behaviours and intracellular structural dynamics. Thus, cell chirality may be a general property of eukaryotic cells. In Drosophila, cell chirality drives the LR asymmetric development of individual organs, without establishing the LR axis of the whole embryo. Considering that organ-intrinsic LR asymmetry is also reported in vertebrates, this mechanism may contribute to LR asymmetric development across phyla.This article is part of the themed issue 'Provocative questions in left-right asymmetry'. © 2016 The Authors.

  6. Analytical linear energy transfer model including secondary particles: calculations along the central axis of the proton pencil beam

    International Nuclear Information System (INIS)

    Marsolat, F; De Marzi, L; Mazal, A; Pouzoulet, F

    2016-01-01

    In proton therapy, the relative biological effectiveness (RBE) depends on various types of parameters such as linear energy transfer (LET). An analytical model for LET calculation exists (Wilkens’ model), but secondary particles are not included in this model. In the present study, we propose a correction factor, L sec , for Wilkens’ model in order to take into account the LET contributions of certain secondary particles. This study includes secondary protons and deuterons, since the effects of these two types of particles can be described by the same RBE-LET relationship. L sec was evaluated by Monte Carlo (MC) simulations using the GATE/GEANT4 platform and was defined by the ratio of the LET d distributions of all protons and deuterons and only primary protons. This method was applied to the innovative Pencil Beam Scanning (PBS) delivery systems and L sec was evaluated along the beam axis. This correction factor indicates the high contribution of secondary particles in the entrance region, with L sec values higher than 1.6 for a 220 MeV clinical pencil beam. MC simulations showed the impact of pencil beam parameters, such as mean initial energy, spot size, and depth in water, on L sec . The variation of L sec with these different parameters was integrated in a polynomial function of the L sec factor in order to obtain a model universally applicable to all PBS delivery systems. The validity of this correction factor applied to Wilkens’ model was verified along the beam axis of various pencil beams in comparison with MC simulations. A good agreement was obtained between the corrected analytical model and the MC calculations, with mean-LET deviations along the beam axis less than 0.05 keV μm −1 . These results demonstrate the efficacy of our new correction of the existing LET model in order to take into account secondary protons and deuterons along the pencil beam axis. (paper)

  7. Analysis of form deviation in non-isothermal glass molding

    Science.gov (United States)

    Kreilkamp, H.; Grunwald, T.; Dambon, O.; Klocke, F.

    2018-02-01

    Especially in the market of sensors, LED lighting and medical technologies, there is a growing demand for precise yet low-cost glass optics. This demand poses a major challenge for glass manufacturers who are confronted with the challenge arising from the trend towards ever-higher levels of precision combined with immense pressure on market prices. Since current manufacturing technologies especially grinding and polishing as well as Precision Glass Molding (PGM) are not able to achieve the desired production costs, glass manufacturers are looking for alternative technologies. Non-isothermal Glass Molding (NGM) has been shown to have a big potential for low-cost mass manufacturing of complex glass optics. However, the biggest drawback of this technology at the moment is the limited accuracy of the manufactured glass optics. This research is addressing the specific challenges of non-isothermal glass molding with respect to form deviation of molded glass optics. Based on empirical models, the influencing factors on form deviation in particular form accuracy, waviness and surface roughness will be discussed. A comparison with traditional isothermal glass molding processes (PGM) will point out the specific challenges of non-isothermal process conditions. Furthermore, the underlying physical principle leading to the formation of form deviations will be analyzed in detail with the help of numerical simulation. In this way, this research contributes to a better understanding of form deviations in non-isothermal glass molding and is an important step towards new applications demanding precise yet low-cost glass optics.

  8. New Urban Vertical Axis Wind Turbine Design

    Directory of Open Access Journals (Sweden)

    Alexandru-Mihai CISMILIANU

    2015-12-01

    Full Text Available This paper develops a different approach for enhancing the performance of Vertical Axis Wind Turbines for the use in the urban or rural environment and remote isolated residential areas. Recently the vertical axis wind turbines (VAWT have become more attractive due to the major advantages of this type of turbines in comparison to the horizontal axis wind turbines. We aim to enhance the overall performance of the VAWT by adding a second set of blades (3 x 2=6 blades following the rules of biplane airplanes. The model has been made to operate at a maximum power in the range of the TSR between 2 to 2.5. The performances of the VAWT were investigated numerically and experimentally and justify the new proposed design.

  9. Congenital left paraduodenal hernia causing chronic abdominal pain and abdominal catastrophe.

    Science.gov (United States)

    Shi, Yan; Felsted, Amy E; Masand, Prakash M; Mothner, Brent A; Nuchtern, Jed G; Rodriguez, J Ruben; Vasudevan, Sanjeev A

    2015-04-01

    Paraduodenal hernias are the most common type of congenital internal hernia. Because of its overall rare incidence, this entity is often overlooked during initial assessment of the patient. Lack of specific diagnostic criteria also makes diagnosis exceedingly difficult, and the resulting diagnostic delays can lead to tragic outcomes for patients. Despite these perceived barriers to timely diagnosis, there may be specific radiographic findings that, when combined with the appropriate constellation of clinical symptoms, would aid in diagnosis. This patient first presented at 8 years of age with vague symptoms of postprandial emesis, chronic abdominal pain, nausea, and syncope. Over the span of 6 years he was evaluated 2 to 3 times a year with similar complaints, all of which quickly resolved spontaneously. He underwent multiple laboratory, imaging, and endoscopic studies, which were nondiagnostic. It was not until he developed signs of a high-grade obstruction and extremis that he was found to have a large left paraduodenal hernia that had volvulized around the superior mesenteric axis. This resulted in the loss of the entire superior mesenteric axis distribution of the small and large intestine and necrosis of the duodenum. In cases of chronic intermittent obstruction without clear etiology, careful attention and consideration should be given to the constellation of symptoms, imaging studies, and potential use of diagnostic laparoscopy. Increased vigilance by primary care and consulting physicians is necessary to detect this rare but readily correctable condition. Copyright © 2015 by the American Academy of Pediatrics.

  10. Incorporating assumption deviation risk in quantitative risk assessments: A semi-quantitative approach

    International Nuclear Information System (INIS)

    Khorsandi, Jahon; Aven, Terje

    2017-01-01

    Quantitative risk assessments (QRAs) of complex engineering systems are based on numerous assumptions and expert judgments, as there is limited information available for supporting the analysis. In addition to sensitivity analyses, the concept of assumption deviation risk has been suggested as a means for explicitly considering the risk related to inaccuracies and deviations in the assumptions, which can significantly impact the results of the QRAs. However, challenges remain for its practical implementation, considering the number of assumptions and magnitude of deviations to be considered. This paper presents an approach for integrating an assumption deviation risk analysis as part of QRAs. The approach begins with identifying the safety objectives for which the QRA aims to support, and then identifies critical assumptions with respect to ensuring the objectives are met. Key issues addressed include the deviations required to violate the safety objectives, the uncertainties related to the occurrence of such events, and the strength of knowledge supporting the assessments. Three levels of assumptions are considered, which include assumptions related to the system's structural and operational characteristics, the effectiveness of the established barriers, as well as the consequence analysis process. The approach is illustrated for the case of an offshore installation. - Highlights: • An approach for assessing the risk of deviations in QRA assumptions is presented. • Critical deviations and uncertainties related to their occurrence are addressed. • The analysis promotes critical thinking about the foundation and results of QRAs. • The approach is illustrated for the case of an offshore installation.

  11. Mapping of the left-sided phrenic nerve course in patients undergoing left atrial catheter ablations.

    Science.gov (United States)

    Huemer, Martin; Wutzler, Alexander; Parwani, Abdul S; Attanasio, Philipp; Haverkamp, Wilhelm; Boldt, Leif-Hendrik

    2014-09-01

    Catheter ablation of atrial fibrillation has been associated with left-sided phrenic nerve palsy. Knowledge of the individual left phrenic nerve course therefore is essential to prevent nerve injury. The aim of this study was to test the feasibility of an intraprocedural pace mapping and reconstruction of the left phrenic nerve course and to characterize which anatomical areas are affected. In patients undergoing left atrial catheter ablation, a three-dimensional map of the left atrial anatomical structures was created. The left-sided phrenic nerve course was determined by high-output pace mapping and reconstructed in the map. In this study, 40 patients with atrial fibrillation or atrial tachycardias were included. Left phrenic nerve capture was observed in 23 (57.5%) patients. Phrenic nerve was captured in 22 (55%) patients inside the left atrial appendage, in 22 (55%) in distal parts, in 21 (53%) in medial parts, and in two (5%) in ostial parts of the appendage. In three (7.5%) patients, capture was found in the distal coronary sinus and in one (2.5%) patient in the left atrium near the left atrial appendage ostium. Ablation target was changed due to direct spatial relationship to the phrenic nerve in three (7.5%) patients. No phrenic nerve palsy was observed. Left-sided phrenic nerve capture was found inside and around the left atrial appendage in the majority of patients and additionally in the distal coronary sinus. Phrenic nerve mapping and reconstruction can easily be performed and should be considered prior catheter ablations in potential affected areas. ©2014 Wiley Periodicals, Inc.

  12. Does standard deviation matter? Using "standard deviation" to quantify security of multistage testing.

    Science.gov (United States)

    Wang, Chun; Zheng, Yi; Chang, Hua-Hua

    2014-01-01

    With the advent of web-based technology, online testing is becoming a mainstream mode in large-scale educational assessments. Most online tests are administered continuously in a testing window, which may post test security problems because examinees who take the test earlier may share information with those who take the test later. Researchers have proposed various statistical indices to assess the test security, and one most often used index is the average test-overlap rate, which was further generalized to the item pooling index (Chang & Zhang, 2002, 2003). These indices, however, are all defined as the means (that is, the expected proportion of common items among examinees) and they were originally proposed for computerized adaptive testing (CAT). Recently, multistage testing (MST) has become a popular alternative to CAT. The unique features of MST make it important to report not only the mean, but also the standard deviation (SD) of test overlap rate, as we advocate in this paper. The standard deviation of test overlap rate adds important information to the test security profile, because for the same mean, a large SD reflects that certain groups of examinees share more common items than other groups. In this study, we analytically derived the lower bounds of the SD under MST, with the results under CAT as a benchmark. It is shown that when the mean overlap rate is the same between MST and CAT, the SD of test overlap tends to be larger in MST. A simulation study was conducted to provide empirical evidence. We also compared the security of MST under the single-pool versus the multiple-pool designs; both analytical and simulation studies show that the non-overlapping multiple-pool design will slightly increase the security risk.

  13. Precision analysis for standard deviation measurements of immobile single fluorescent molecule images.

    Science.gov (United States)

    DeSantis, Michael C; DeCenzo, Shawn H; Li, Je-Luen; Wang, Y M

    2010-03-29

    Standard deviation measurements of intensity profiles of stationary single fluorescent molecules are useful for studying axial localization, molecular orientation, and a fluorescence imaging system's spatial resolution. Here we report on the analysis of the precision of standard deviation measurements of intensity profiles of single fluorescent molecules imaged using an EMCCD camera.We have developed an analytical expression for the standard deviation measurement error of a single image which is a function of the total number of detected photons, the background photon noise, and the camera pixel size. The theoretical results agree well with the experimental, simulation, and numerical integration results. Using this expression, we show that single-molecule standard deviation measurements offer nanometer precision for a large range of experimental parameters.

  14. Linear maps preserving maximal deviation and the Jordan structure of quantum systems

    International Nuclear Information System (INIS)

    Hamhalter, Jan

    2012-01-01

    In the algebraic approach to quantum theory, a quantum observable is given by an element of a Jordan algebra and a state of the system is modelled by a normalized positive functional on the underlying algebra. Maximal deviation of a quantum observable is the largest statistical deviation one can obtain in a particular state of the system. The main result of the paper shows that each linear bijective transformation between JBW algebras preserving maximal deviations is formed by a Jordan isomorphism or a minus Jordan isomorphism perturbed by a linear functional multiple of an identity. It shows that only one numerical statistical characteristic has the power to determine the Jordan algebraic structure completely. As a consequence, we obtain that only very special maps can preserve the diameter of the spectra of elements. Nonlinear maps preserving the pseudometric given by maximal deviation are also described. The results generalize hitherto known theorems on preservers of maximal deviation in the case of self-adjoint parts of von Neumann algebras proved by Molnár.

  15. Deviations in human gut microbiota

    DEFF Research Database (Denmark)

    Casén, C; Vebø, H C; Sekelja, M

    2015-01-01

    microbiome profiling. AIM: To develop and validate a novel diagnostic test using faecal samples to profile the intestinal microbiota and identify and characterise dysbiosis. METHODS: Fifty-four DNA probes targeting ≥300 bacteria on different taxonomic levels were selected based on ability to distinguish......, and potential clinically relevant deviation in the microbiome from normobiosis. This model was tested in different samples from healthy volunteers and IBS and IBD patients (n = 330) to determine the ability to detect dysbiosis. RESULTS: Validation confirms dysbiosis was detected in 73% of IBS patients, 70...

  16. 9 CFR 381.308 - Deviations in processing.

    Science.gov (United States)

    2010-01-01

    ...) must be handled according to: (1)(i) A HACCP plan for canned product that addresses hazards associated... (d) of this section. (c) [Reserved] (d) Procedures for handling process deviations where the HACCP... accordance with the following procedures: (a) Emergency stops. (1) When retort jams or breakdowns occur...

  17. À esquerda da tradição / To the left of tradition

    Directory of Open Access Journals (Sweden)

    Wellington Teodoro da Silva

    2010-01-01

    Full Text Available O movimento conhecido como esquerda católica organizou-se ao entorno de três eixos: 1 a consciência histórica e a consciência da história; 2 a revolução cristã e 3 a fidelidade à grande tradição. Este artigo trata deste último eixo que constitui o empenho desse movimento em mostrar-se como o fiel intérprete da longuíssima tradição do catolicismoromano. / The movement known as Catholic Left is organized around three axes: 1 the historical consciousness and the awareness of history, 2 the Christian revolution and 3 the loyalty to the great tradition. This article deals with this last axis, which constitutes the commitment of this movement to show itself as the faithful interpreter of the very longtradition of Roman Catholicism.

  18. Deviations from LTE in a stellar atmosphere

    International Nuclear Information System (INIS)

    Kalkofen, W.; Klein, R.I.; Stein, R.F.

    1979-01-01

    Deviations from LTE are investigated in an atmosphere of hydrogen atoms with one bound level, satisfying the equations of radiative, hydrostatic, and statistical equilibrium. The departure coefficient and the kinetic temperature as functions of the frequency dependence of the radiative cross section are studied analytically and numerically. Near the outer boundary of the atmosphere, the departure coefficient b is smaller than unity when the radiative cross section αsub(ν) grows with frequency ν faster than ν 2 ; b exceeds unity otherwise. Far from the boundary the departure coefficient tends to exceed unity for any frequency dependence of αsub(ν). Overpopulation (b > 1) always implies that the kinetic temperature in the statistical equilibrium atmosphere is higher than the temperature in the corresponding LTE atmosphere. Upper and lower bounds on the kinetic temperature are given for an atmosphere with deviations from LTE only in the optically shallow layers when the emergent intensity can be described by a radiation temperature. (author)

  19. Deviations from LTE in a stellar atmosphere

    Science.gov (United States)

    Kalkofen, W.; Klein, R. I.; Stein, R. F.

    1979-01-01

    Deviations for LTE are investigated in an atmosphere of hydrogen atoms with one bound level, satisfying the equations of radiative, hydrostatic, and statistical equilibrium. The departure coefficient and the kinetic temperature as functions of the frequency dependence of the radiative cross section are studied analytically and numerically. Near the outer boundary of the atmosphere, the departure coefficient is smaller than unity when the radiative cross section grows with frequency faster than with the square of frequency; it exceeds unity otherwise. Far from the boundary the departure coefficient tends to exceed unity for any frequency dependence of the radiative cross section. Overpopulation always implies that the kinetic temperature in the statistical-equilibrium atmosphere is higher than the temperature in the corresponding LTE atmosphere. Upper and lower bounds on the kinetic temperature are given for an atmosphere with deviations from LTE only in the optically shallow layers when the emergent intensity can be described by a radiation temperature.

  20. [Kennedy V Axis assessment in an Italian outpatient and inpatient population].

    Science.gov (United States)

    Mundo, Emanuela; Bonalume, Laura; Del Corno, Franco; Madeddu, Fabio; Lang, Margherita

    2010-01-01

    Kennedy Axis V or K Axis acts is an alternative tool to the DSM-IVTR Global Assessment of Functioning (GAF) Scale, that many researchers describe as a scale with poor inter-rater reliability and clinical utility. Unlike the GAF scale, K Axis provides a multidimensional and multiaxial approach to measure personal, social and interpersonal functioning in psychiatric outpatients and inpatients. In this study, we examined K Axis's inter-raters reliability by using it with an Italian clinical population. Clinicians used Kennedy Axis V to assess global functioning among 180 inpatients, in 9 psychiatric services in Lombardia and Piemonte. Patients were divided into 4 different diagnostic groups, according to the DSM-IV-TR criteria. Intraclass correlations between two independent raters's scores reveal high level of interrater reliability for all K Axis scales (0,633 < ICC < 0,813). Highly significant results in the Kruskal-Wallis test demonstrate that the patient diagnosis influence all the scales scores. Significant differences in patients functioning profiles in all K Axis scales, apart from Violence one, were noted between different diagnosis groups. In this study high level of raters agreement was noted, even if K Axis scales were used in different mental health services from different clinicians. K Axis scales provide a useful profile of patient global functioning, in line with the specific pathology.

  1. Process Measurement Deviation Analysis for Flow Rate due to Miscalibration

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Eunsuk; Kim, Byung Rae; Jeong, Seog Hwan; Choi, Ji Hye; Shin, Yong Chul; Yun, Jae Hee [KEPCO Engineering and Construction Co., Deajeon (Korea, Republic of)

    2016-10-15

    An analysis was initiated to identify the root cause, and the exemption of high static line pressure correction to differential pressure (DP) transmitters was one of the major deviation factors. Also the miscalibrated DP transmitter range was identified as another major deviation factor. This paper presents considerations to be incorporated in the process flow measurement instrumentation calibration and the analysis results identified that the DP flow transmitter electrical output decreased by 3%. Thereafter, flow rate indication decreased by 1.9% resulting from the high static line pressure correction exemption and measurement range miscalibration. After re-calibration, the flow rate indication increased by 1.9%, which is consistent with the analysis result. This paper presents the brief calibration procedures for Rosemount DP flow transmitter, and analyzes possible three cases of measurement deviation including error and cause. Generally, the DP transmitter is required to be calibrated with precise process input range according to the calibration procedure provided for specific DP transmitter. Especially, in case of the DP transmitter installed in high static line pressure, it is important to correct the high static line pressure effect to avoid the inherent systematic error for Rosemount DP transmitter. Otherwise, failure to notice the correction may lead to indicating deviation from actual value.

  2. Family history study of the familial coaggregation of borderline personality disorder with axis I and nonborderline dramatic cluster axis II disorders.

    Science.gov (United States)

    Zanarini, Mary C; Barison, Leah K; Frankenburg, Frances R; Reich, D Bradford; Hudson, James I

    2009-08-01

    The purpose of this study was to assess the familial coaggregation of borderline personality disorder (BPD) with a full array of axis I disorders and four axis II disorders (antisocial personality disorder, histrionic personality disorder, narcissistic personality disorder, and sadistic personality disorder) in the first-degree relatives of borderline probands and axis II comparison subjects. Four hundred and forty-five inpatients were interviewed about familial psychopathology using the Revised Family History Questionnaire-a semistructured interview of demonstrated reliability. Of these 445 subjects, 341 met both DIB-R and DSM-III-R criteria for BPD and 104 met DSM-III-R criteria for another type of personality disorder (and neither criteria set for BPD). The psychopathology of 1,580 first-degree relatives of borderline probands and 472 relatives of axis II comparison subjects was assessed. Using structural models for familial coaggregation, it was found that BPD coaggregates with major depression, dysthymic disorder, bipolar I disorder, alcohol abuse/dependence, drug abuse/dependence, panic disorder, social phobia, obsessive-compulsive disorder, generalized anxiety disorder, posttraumatic stress disorder, somatoform pain disorder, and all four axis II disorders studied. Taken together, the results of this study suggest that common familial factors, particularly in the areas of affective disturbance and impulsivity, contribute to borderline personality disorder.

  3. Analysis and design of a vertical axis wind turbine

    OpenAIRE

    Goyena Iriso, Joseba

    2011-01-01

    The main objective of this project is to design a new vertical axis wind turbine, specifically one Giromill wind turbine. The project development requires performing a previous study of the vertical axis wind turbines currently development. This study has to be performed before starting to design the wind turbine. Other very important aim is the development of a new vertical axis wind turbine. The after analyses that will result in the final design of the wind turbine will b...

  4. Self-starting aerodynamics analysis of vertical axis wind turbine

    OpenAIRE

    Jianyang Zhu; Hailin Huang; Hao Shen

    2015-01-01

    Vertical axis wind turbine is a special type of wind-force electric generator which is capable of working in the complicated wind environment. The self-starting aerodynamics is one of the most important considerations for this kind of turbine. This article aims at providing a systematic synthesis on the self-starting aerodynamic characteristics of vertical axis wind turbine based on the numerical analysis approach. First, the physical model of vertical axis wind turbine and its parameter defi...

  5. Wave refraction and backward magnon-plasmon polaritons in left-handed antiferromagnet/semiconductor superlattices

    International Nuclear Information System (INIS)

    Tarkhanyan, R.H.; Niarchos, D.G.

    2007-01-01

    Characteristics of the bulk electromagnetic waves in teraHertz frequency region are examined in a left-handed superlattice (SL) which consists of alternating layers of nonmagnetic semiconductor and nonconducting antiferromagnetic materials. General problem on the sign of the refractive index for anisotropic media is considered. It is shown that the phase refraction index is always positive while the group refractive index can be negative when some general conditions are fulfilled. Effective permittivity and permeability tensors of the SL are derived for perpendicular and parallel orientation of the magnetic anisotropy axis with respect to the plane of the layers. Problem of anomalous refraction for transverse electric and transverse magnetic-type polarized waves is examined in such media. Analytical expressions for both the phase and group refractive indices are obtained for various propagated modes. It is shown that, in general, three different types of the refracted waves with different relative orientation of the phase and group velocity vectors are possible in left-handed media. Unusual peculiarities of the backward modes corresponding to the coupled magnon-plasmon polaritons are considered. It is shown, in particular, that the number of the backward modes depends on the free charge carrier's density in semiconductor layers, variation of which allows to create different frequency regions for the wave propagation

  6. Advantages of heavy metal collars in directional drilling and deviation control

    International Nuclear Information System (INIS)

    Bradley, W.B.; Murphey, C.E.; McLamore, R.T.; Dickson, L.L.

    1976-01-01

    A heavy, stiff-bottom drill collar can substantially improve deviation performance, theoretically increasing penetration rates by 50 to 100 percent in deviation-prone areas. This paper presents the underlying theory, practical charts on performance characteristics, and Shell Development Co.'s experience in fabricating and field testing two depleted-uranium alloy, heavy metal collars

  7. The Analysis of a Deviation of Investment and Corporate Governance

    OpenAIRE

    Shoichi Hisa

    2008-01-01

    Investment of firms is affected by not only fundamentals factors, but liquidity constraint, ownership or corporate structure. Information structure between manager and owner is a significant factor to decide the level of investment, and deviation of investment from optimal condition. The reputation model between manager and owner suggest that the separate of ownership and management may induce the deviation of investment, and indicate that governance structure is important to reduce it. In th...

  8. Sample-path large deviations in credit risk

    NARCIS (Netherlands)

    Leijdekker, V.J.G.; Mandjes, M.R.H.; Spreij, P.J.C.

    2011-01-01

    The event of large losses plays an important role in credit risk. As these large losses are typically rare, and portfolios usually consist of a large number of positions, large deviation theory is the natural tool to analyze the tail asymptotics of the probabilities involved. We first derive a

  9. Effects of the APC materials on c-axis correlated pinning effects in a-axis oriented Y123/2D APC multilayer films

    International Nuclear Information System (INIS)

    Takamura, M.; Mukaida, M.; Horii, S.; Ichinose, A.; Kita, R.; Namba, M.; Awaji, S.; Watanabe, K.; Matsumoto, K.; Yoshida, Y.; Teranishi, R.; Yamada, K.; Mori, N.

    2009-01-01

    For a-axis oriented and c-axis in-plane aligned YBa 2 Cu 3 O 7-δ /artificial pinning center (Y123/APC) alternately-layered thin films, effects of the APC materials on the multilayer structures are discussed. Pr123, (Y 1-x Pr x )123 and Gd 2 CuO 4 (Gd214) were used as APCs. The multilayer structure was observed for Y123/Pr123 films and Y123/Gd214 films. However, some grains are also grown in the Y123/Gd214 film. For the Y123/Pr123 multilayer film, each Pr123 layer act as two-dimensional APCs (2D APCs) in the magnetic field angular dependences of the critical current density. The growth mechanism of the multilayer structure in the Y123/2D APC films is discussed by a transmission electron microscopy and an atomic force microscope. It is found that two conditions are needed to obtain the c-axis correlated pinning effects by 2D APC in the a-axis oriented and c-axis in-plane aligned Y123/APC multilayer films: the same structure as Y123; Y-free APC materials.

  10. Off-axis and inline electron holography: Experimental comparison

    International Nuclear Information System (INIS)

    Latychevskaia, Tatiana; Formanek, Petr; Koch, C.T.; Lubk, Axel

    2010-01-01

    Electron holography is a very powerful technique for mapping static electric and magnetic potentials down to atomic resolution. While electron holography is commonly considered synonymous with its off-axis variant in the high energy electron microscopy community, inline electron holography is widely applied in low-energy electron microscopy, where the realization of the off-axis setup is still an experimental challenge. This paper demonstrates that both inline and off-axis holography may be used to recover amplitude and phase shift of the very same object, in our example latex spheres of 90 and 200 nm in diameter, producing very similar results, provided the object does not charge under the electron beam.

  11. Experimental hyperthyroidism and central mediators of stress axis and thyroid axis activity in common carp (Cyprinus carpio L.).

    Science.gov (United States)

    Geven, Edwin J W; Verkaar, Folkert; Flik, Gert; Klaren, Peter H M

    2006-12-01

    The effect of experimental hyperthyroidism, realized by T(4) injection, on central mediators of the hypothalamo-pituitary-interrenal axis (HPI-axis) in common carp (Cyprinus carpio L.) was studied. Our results show that hyperthyroidism evokes a marked 3.2-fold reduction in basal plasma cortisol levels. Corticotropin-releasing hormone-binding protein (CRH-BP) mRNA levels in the hypothalamus, measured by real-time quantitative PCR, were significantly elevated by 40%, but CRH, urotensin-I, prepro-TRH, prohormone convertase-1 (PC1), and POMC mRNA levels were unchanged. In the pituitary pars distalis, PC1, CRH receptor-1, and POMC mRNA levels were unaffected, as was ACTH content. Plasma alpha-MSH concentrations were significantly elevated by 30% in hyperthyroid fish, and this was reflected in PC1 and POMC mRNA levels in pituitary pars intermedia that were increased 1.5- and 2.4-fold respectively. The alpha-MSH content of the pars intermedia was unchanged. Hyperthyroidism has profound effects on the basal levels of a central mediator, i.e., CRH-BP, of HPI-axis function in unstressed carp in vivo, and we conclude that HPI- and hypothalamo-pituitary-thyroid-axis functions are strongly interrelated. We suggest that the changes in plasma cortisol, thyroid hormone, and alpha-MSH levels reflect their concerted actions on energy metabolism.

  12. Bodily Deviations and Body Image in Adolescence

    Science.gov (United States)

    Vilhjalmsson, Runar; Kristjansdottir, Gudrun; Ward, Dianne S.

    2012-01-01

    Adolescents with unusually sized or shaped bodies may experience ridicule, rejection, or exclusion based on their negatively valued bodily characteristics. Such experiences can have negative consequences for a person's image and evaluation of self. This study focuses on the relationship between bodily deviations and body image and is based on a…

  13. Analyzing Menton Deviation in Posteroanterior Cephalogram in Early Detection of Temporomandibular Disorder

    Directory of Open Access Journals (Sweden)

    Trelia Boel

    2017-01-01

    Full Text Available Introduction. Some clinicians believed that mandibular deviation leads to facial asymmetry and it also had a correlation with temporomandibular disorders (TMDs. Posteroanterior (PA cephalogram was widely reported as a regular record in treating facial asymmetry and craniofacial anomalies. The objective of this study was to analyze the relationship of menton deviation in PA cephalogram with temporomandibular disorders (TMDs symptoms. Materials and Methods. TMJ function was initially screened based on TMD-DI questionnaire. PA cephalogram of volunteer subjects with TMDs (n=37 and without TMDs (n=33 with mean age of 21.61±2.08 years was taken. The menton deviation was measured by the distance (mm from menton point to midsagittal reference (MSR horizontally, using software digitized measurement, and categorized as asymmetric if the value is greater than 3 mm. The prevalence and difference of menton deviation in both groups were evaluated by unpaired t-test. Result. The prevalence of symmetry group showed that 65.9% had no TMDs with mean of 1,815 ± 0,71 mm; in contrast, the prevalence of asymmetry group showed that 95.5% reported TMDs with mean of 3,159 ± 1,053 mm. There was a significant difference of menton deviation to TMDs (p=0.000 in subjects with and without TMDs. Conclusion. There was a significant relationship of menton deviation in PA cephalogram with TMDs based on TMD-DI index.

  14. Why do lesser toes deviate laterally in hallux valgus? A radiographic study.

    Science.gov (United States)

    Roan, Li-Yi; Tanaka, Yasuhito; Taniguchi, Akira; Tomiwa, Kiyonori; Kumai, Tsukasa; Cheng, Yuh-Min

    2015-06-01

    Hallux valgus foot with laterally deviated lesser toes is a complex condition to treat. Ignoring the laterally deviated lesser toes in hallux valgus might result in unsatisfactory foot shape. Without lateral support of the lesser toes, it might increase the risk of recurrence of hallux valgus. We sought to identify associated radiographic findings in patients where lesser toes follow the great toe in hallux valgus and deviate laterally. The weight-bearing, anteroposterior foot radiographs of 24 female hallux valgus feet with laterally deviated lesser toes (group L), 34 female hallux valgus feet with normal lesser toes (group H), and 43 normal female feet (group N) were selected for the study. A 2-dimensional coordinated system was used to analyze the shapes and angles of these feet by converting each dot made on the radiographs onto X and Y coordinates. Diagrams of the feet in each group were drawn for comparison. The hallux valgus angle, lateral deviation angle of the second toe, intermetatarsal angles, toe length, metatarsal length, and metatarsus adductus were calculated according to the coordinates of the corresponding points. The mapping showed the bases of the second, third, and fourth toe in group L shifted laterally away from their corresponding metatarsal head (P hallux valgus angles (P hallux valgus angle, more adducted first metatarsal, and divergent lateral splaying of the lesser metatarsals were associated with lateral deviation of the lesser toes in hallux valgus. Level III, comparative study. © The Author(s) 2015.

  15. Large deviations and portfolio optimization

    Science.gov (United States)

    Sornette, Didier

    Risk control and optimal diversification constitute a major focus in the finance and insurance industries as well as, more or less consciously, in our everyday life. We present a discussion of the characterization of risks and of the optimization of portfolios that starts from a simple illustrative model and ends by a general functional integral formulation. A major item is that risk, usually thought of as one-dimensional in the conventional mean-variance approach, has to be addressed by the full distribution of losses. Furthermore, the time-horizon of the investment is shown to play a major role. We show the importance of accounting for large fluctuations and use the theory of Cramér for large deviations in this context. We first treat a simple model with a single risky asset that exemplifies the distinction between the average return and the typical return and the role of large deviations in multiplicative processes, and the different optimal strategies for the investors depending on their size. We then analyze the case of assets whose price variations are distributed according to exponential laws, a situation that is found to describe daily price variations reasonably well. Several portfolio optimization strategies are presented that aim at controlling large risks. We end by extending the standard mean-variance portfolio optimization theory, first within the quasi-Gaussian approximation and then using a general formulation for non-Gaussian correlated assets in terms of the formalism of functional integrals developed in the field theory of critical phenomena.

  16. A study on the deviation aspects of the poem “The Eightieth Stage”

    Directory of Open Access Journals (Sweden)

    Soghra Salmaninejad Mehrabadi

    2016-02-01

    Full Text Available Abstract  One of the methods of literature review is addressing the literary forms that deeply attracted formalists’ attention. Formalists emphasizes certain shapes and forms and methods of literary language. In their view, the task of literature and art is not making known but representing the elements in the realm of art. So, for creating an outstanding work, novelty is not just important, but modes of expression can show a new dimension of the world to audience.   Shklovsky raised for the first time the term “de familiarization”. In his opinion, art renews sensory perception and transforms the familiar rules and seemingly enduring structures of reality. He believes defamiliarization is seeing things out of their natural context. According to Leach, the two usual methods to distinguish the general language from the language of arts are rule-increasing and rule-decreasing.   In deviation occurs a resurrection of words and the author creates a double pleasure through language games in contact with the audience. Imagery, music and syntax can produce a kind of defamiliarization.   Akhavan in the poem “The Eightieth Stag e ” has used a variety of deviations. The first is in the name of poetry. In this paper, the norms of lexical, semantic and stylistic in the poem “Eightieth Stage” is checked.   Lexical deviation Sartre says the poet does not use the words, but sometimes words would use the new syntax. Akhavan in the words sometimes making terms such as “mardestan (masculinity, faramoshzar (plains of oblivion, gandomand (Robust, golazin (inflorescence, parhib (deception and ...” and sometimes new compounds alters magically the effect of poetry. His compounds like talaei makhmal avayan (golden voices and velvet, pak ayin (clean rituals, malmalin dastar (silver turban, marde mardestan (men of masculinity, rakhshe rakhshande (the brilliant horse and…" makes illustration that in some of synergistic base has helped to the poet

  17. OBSERVABLE DEVIATIONS FROM HOMOGENEITY IN AN INHOMOGENEOUS UNIVERSE

    Energy Technology Data Exchange (ETDEWEB)

    Giblin, John T. Jr. [Department of Physics, Kenyon College, 201 N College Road Gambier, OH 43022 (United States); Mertens, James B.; Starkman, Glenn D. [CERCA/ISO, Department of Physics, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, OH 44106 (United States)

    2016-12-20

    How does inhomogeneity affect our interpretation of cosmological observations? It has long been wondered to what extent the observable properties of an inhomogeneous universe differ from those of a corresponding Friedmann–Lemaître–Robertson–Walker (FLRW) model, and how the inhomogeneities affect that correspondence. Here, we use numerical relativity to study the behavior of light beams traversing an inhomogeneous universe, and construct the resulting Hubble diagrams. The universe that emerges exhibits an average FLRW behavior, but inhomogeneous structures contribute to deviations in observables across the observer’s sky. We also investigate the relationship between angular diameter distance and the angular extent of a source, finding deviations that grow with source redshift. These departures from FLRW are important path-dependent effects, with implications for using real observables in an inhomogeneous universe such as our own.

  18. OBSERVABLE DEVIATIONS FROM HOMOGENEITY IN AN INHOMOGENEOUS UNIVERSE

    International Nuclear Information System (INIS)

    Giblin, John T. Jr.; Mertens, James B.; Starkman, Glenn D.

    2016-01-01

    How does inhomogeneity affect our interpretation of cosmological observations? It has long been wondered to what extent the observable properties of an inhomogeneous universe differ from those of a corresponding Friedmann–Lemaître–Robertson–Walker (FLRW) model, and how the inhomogeneities affect that correspondence. Here, we use numerical relativity to study the behavior of light beams traversing an inhomogeneous universe, and construct the resulting Hubble diagrams. The universe that emerges exhibits an average FLRW behavior, but inhomogeneous structures contribute to deviations in observables across the observer’s sky. We also investigate the relationship between angular diameter distance and the angular extent of a source, finding deviations that grow with source redshift. These departures from FLRW are important path-dependent effects, with implications for using real observables in an inhomogeneous universe such as our own.

  19. Angular momentum projection of tilted axis rotating states

    Energy Technology Data Exchange (ETDEWEB)

    Oi, M; Onishi, N; Tajima, N [Tokyo Univ. (Japan); Horibata, T

    1998-03-01

    We applied an exact angular momentum projection to three dimensional cranked HFB (3d-CHFB) states. Tilted axis rotating states (TAR) and principal axis rotating states (PAR) are compared. It is shown that TAR is more adequate than PAR for description of the back bending phenomena driven by tilted rotation or wobbling motion. (author)

  20. UARS PEM Level 2 AXIS 2 V001 (UARPE2AXIS2) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — The UARS Particle Environment Monitor (PEM) level 2 Atmosphere X-Ray Imaging Spectrometer (AXIS) unit 2 daily product contains the X-ray high-resolution spectral...

  1. UARS PEM Level 2 AXIS 1 V001 (UARPE2AXIS1) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — The UARS Particle Environment Monitor (PEM) level 2 Atmosphere X-Ray Imaging Spectrometer (AXIS) unit 1 daily product contains the X-ray high-resolution spectral...

  2. TMS over the Left Angular Gyrus Impairs the Ability to Discriminate Left from Right

    Science.gov (United States)

    Hirnstein, Marco; Bayer, Ulrike; Ellison, Amanda; Hausmann, Markus

    2011-01-01

    The underlying cognitive and neural mechanisms of the ability to discriminate left from right are hardly explored. Clinical studies from patients with impairments of left-right discrimination (LRD) and neuroimaging data suggest that the left angular gyrus is particularly involved in LRD. Moreover, it is argued that the often reported sex…

  3. Phytochemicals for taming agitated immune-endocrine-neural axis.

    Science.gov (United States)

    Patel, Seema

    2017-07-01

    Homeostasis of immune-endocrine-neural axis is paramount for human health. If this axis gets agitated due to age, genetic variations, environmental exposures or lifestyle assaults, a cascade of adverse reactions occurs in human body. Cytokines, hormones and neurotransmitters, the effector molecules of this axis behave erratically, leading to a gamut of neural, endocrine, autoimmune, and metabolic diseases. Current panel of drugs can tackle some of them but not in a sustainable, benign way as a myriad of side effects, causal of them have been documented. In this context, phytochemicals, the secondary metabolites of plants seem beneficial. These bioactive constituents encompassing polyphenols, alkaloids, flavonoids, terpenoids, tannins, lignans, stilbenoids (resveratrol), saponins, polysaccharides, glycosides, and lectins etc. have been proven to exert antioxidant, anti-inflammatory, hypolipidemic, hypotensive, antidiabetic, anticancer, immunomodulatory, anti-allergic, analgesic, hepatoprotective, neuroprotective, dermatoprotective, and antimicrobial properties, among a litany of other biological effects. This review presents a holistic perspective of common afflictions resultant of immune-endocrine-neural axis disruption, and the phytochemicals capable of restoring their normalcy and mitigating the ailments. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  4. Modal Parameter Identification of New Design of Vertical Axis Wind Turbine

    DEFF Research Database (Denmark)

    Chougule, Prasad; Nielsen, Søren R.K.

    2013-01-01

    Vertical axis wind turbines have lower power efficiency than the horizontal axis wind turbines. However vertical axis wind turbines are proven to be economical and noise free on smaller scale. A new design of three bladed vertical axis wind turbine by using two airfoils in construction of each...... blade has been proposed to improve power efficiency. The purpose of two airfoils in blade design of vertical axis wind turbine is to create high lift which in turns gives higher power output. In such case the structural parameter identification is important to understand the system behavior due to its...... first kind of design before experimental analysis. Therefore a study is carried out to determine the natural frequency to avoid unstable state of the system due to rotational frequency of rotor. The present paper outlines a conceptual design of vertical axis wind turbine and a modal analysis by using...

  5. Subquadratic medial-axis approximation in $\\mathbb{R}^3$

    Directory of Open Access Journals (Sweden)

    Christian Scheffer

    2015-09-01

    Full Text Available We present an algorithm that approximates the medial axis of a smooth manifold in $\\mathbb{R}^3$ which is given by a sufficiently dense point sample. The resulting, non-discrete approximation is shown to converge to the medial axis as the sampling density approaches infinity. While all previous algorithms guaranteeing convergence have a running time quadratic in the size $n$ of the point sample, we achieve a running time of at most $\\mathcal{O}(n\\log^3 n$. While there is no subquadratic upper bound on the output complexity of previous algorithms for non-discrete medial axis approximation, the output of our algorithm is guaranteed to be of linear size.

  6. Postnatal development of the atlas and axis: CT study

    International Nuclear Information System (INIS)

    Byun, Sung Su; Kim, Hyung Jin; Lim, Myung Kwan; Kim, Won Hong; Jeon, Yong Sun; Kim, Jeong Ho; Kim, Sung Tae

    2003-01-01

    To evaluate normal postnatal development of the atlas and axis by means of CT scanning. We prospectively analyzed CT scans of the developing atlas and axis of 200 normal children aged less than 14, investigating the CT appearance of these regions with particular attenuation to two synchondroses related to the atlas and four synchondroses and one ossification center related to the axis. Fusion varying was categorized as either low (grade1-5) or high (grade4-5), according to the varying degrees of fusion at each synchondrosis of ossification center. Neurocentral synchondrosis of the atlas was low grade in all children less than five, and high grade in all aged nine or more, while posterior synchondrosis of the atlas was low grade in 97% of children less than three and high grade in 99% aged three or more. As for the axis, neurocentral synchondrosis was low grade in all children less than three, and high grade in 97% of children aged five or more. PS of the axis was low grade in both children less than 6 months, and high grade in all aged two years or more. Dentocentral synchondrosis of the axis was low grade in 93% of children less than three and high grade in 96% of those aged at least five. Intradental axial synchondrosis was high grade in all children. Fusion of the terminal ossicle with the remainder of the dens was low in all children less than five and high in 97% of those aged nine of more. CT can help determine the parameters of normal postnatal development of the atlas and axis. A knowledge of normal ossification patterns of these regions may help provide an understanding of developmental anomalies and also help prevent confusion with fractures

  7. 1 CFR 21.14 - Deviations from standard organization of the Code of Federal Regulations.

    Science.gov (United States)

    2010-01-01

    ... 1 General Provisions 1 2010-01-01 2010-01-01 false Deviations from standard organization of the... CODIFICATION General Numbering § 21.14 Deviations from standard organization of the Code of Federal Regulations. (a) Any deviation from standard Code of Federal Regulations designations must be approved in advance...

  8. A deviation display method for visualising data in mobile gamma-ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Kock, Peder, E-mail: Peder.Kock@med.lu.s [Department of Medical Radiation Physics, Clinical Sciences, Lund University, University Hospital, SE-221 85 Lund (Sweden); Finck, Robert R. [Swedish Radiation Protection Authority, SE-171 16 Stockholm (Sweden); Nilsson, Jonas M.C.; Ostlund, Karl; Samuelsson, Christer [Department of Medical Radiation Physics, Clinical Sciences, Lund University, University Hospital, SE-221 85 Lund (Sweden)

    2010-09-15

    A real time visualisation method, to be used in mobile gamma-spectrometric search operations using standard detector systems is presented. The new method, called deviation display, uses a modified waterfall display to present relative changes in spectral data over energy and time. Using unshielded {sup 137}Cs and {sup 241}Am point sources and different natural background environments, the behaviour of the deviation displays is demonstrated and analysed for two standard detector types (NaI(Tl) and HPGe). The deviation display enhances positive significant changes while suppressing the natural background fluctuations. After an initialisation time of about 10 min this technique leads to a homogeneous display dominated by the background colour, where even small changes in spectral data are easy to discover. As this paper shows, the deviation display method works well for all tested gamma energies and natural background radiation levels and with both tested detector systems.

  9. A deviation display method for visualising data in mobile gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Kock, Peder; Finck, Robert R.; Nilsson, Jonas M.C.; Ostlund, Karl; Samuelsson, Christer

    2010-01-01

    A real time visualisation method, to be used in mobile gamma-spectrometric search operations using standard detector systems is presented. The new method, called deviation display, uses a modified waterfall display to present relative changes in spectral data over energy and time. Using unshielded 137 Cs and 241 Am point sources and different natural background environments, the behaviour of the deviation displays is demonstrated and analysed for two standard detector types (NaI(Tl) and HPGe). The deviation display enhances positive significant changes while suppressing the natural background fluctuations. After an initialisation time of about 10 min this technique leads to a homogeneous display dominated by the background colour, where even small changes in spectral data are easy to discover. As this paper shows, the deviation display method works well for all tested gamma energies and natural background radiation levels and with both tested detector systems.

  10. Adversity-driven changes in hypothalamic-pituitary-adrenal axis functioning during adolescence

    NARCIS (Netherlands)

    Laceulle, O.M.; Nederhof, Esther; van Aken, M.A.G.; Ormel, Johan

    2017-01-01

    The hypothalamic-pituitary-adrenal (HPA) axis has been proposed to be a key mechanism underlying the link between adversity and mental health, but longitudinal studies on adversity and HPA-axis functioning are scarce. Here, we studied adversity-driven changes in HPA-axis functioning during

  11. The development of a decision analytic model of changes in mean deviation in people with glaucoma: the COA model.

    Science.gov (United States)

    Kymes, Steven M; Lambert, Dennis L; Lee, Paul P; Musch, David C; Siegfried, Carla J; Kotak, Sameer V; Stwalley, Dustin L; Fain, Joel; Johnson, Chris; Gordon, Mae O

    2012-07-01

    To create and validate a statistical model predicting progression of primary open-angle glaucoma (POAG) assessed by loss of visual field as measured in mean deviation (MD) using 3 landmark studies of glaucoma progression and treatment. A Markov decision analytic model using patient level data described longitudinal MD changes over 7 years. Patient-level data from the Collaborative Initial Glaucoma Treatment Study (n = 607), the Ocular Hypertension Treatment Study (OHTS; n = 148; only those who developed POAG in the first 5 years of OHTS) and Advanced Glaucoma Intervention Study (n = 591), the COA model. We developed a Markov model with transition matrices stratified by current MD, age, race, and intraocular pressure categories and used a microsimulation approach to estimate change in MD over 7 years. Internal validation compared model prediction for 7 years to actual MD for COA participants. External validation used a cohort of glaucoma patients drawn from university clinical practices. Change in visual field as measured in MD in decibels (dB). Regressing the actual MD against the predicted produced an R(2) of 0.68 for the right eye and 0.63 for the left. The model predicted ending MD for right eyes of 65% of participants and for 63% of left eyes within 3 dB of actual results at 7 years. In external validation the model had an R(2) of 0.79 in the right eye and 0.77 in the left at 5 years. The COA model is a validated tool for clinicians, patients, and health policy makers seeking to understand longitudinal changes in MD in people with glaucoma. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  12. Deviations from Vegard’s law in ternary III-V alloys

    KAUST Repository

    Murphy, S. T.

    2010-08-03

    Vegard’s law states that, at a constant temperature, the volume of an alloy can be determined from a linear interpolation of its constituent’s volumes. Deviations from this description occur such that volumes are both greater and smaller than the linear relationship would predict. Here we use special quasirandom structures and density functional theory to investigate such deviations for MxN1−xAs ternary alloys, where M and N are group III species (B, Al, Ga, and In). Our simulations predict a tendency, with the exception of AlxGa1−xAs, for the volume of the ternary alloys to be smaller than that determined from the linear interpolation of the volumes of the MAs and BAs binary alloys. Importantly, we establish a simple relationship linking the relative size of the group III atoms in the alloy and the predicted magnitude of the deviation from Vegard’s law.

  13. Low frequency vibrations disrupt left-right patterning in the Xenopus embryo.

    Directory of Open Access Journals (Sweden)

    Laura N Vandenberg

    Full Text Available The development of consistent left-right (LR asymmetry across phyla is a fascinating question in biology. While many pharmacological and molecular approaches have been used to explore molecular mechanisms, it has proven difficult to exert precise temporal control over functional perturbations. Here, we took advantage of acoustical vibration to disrupt LR patterning in Xenopus embryos during tightly-circumscribed periods of development. Exposure to several low frequencies induced specific randomization of three internal organs (heterotaxia. Investigating one frequency (7 Hz, we found two discrete periods of sensitivity to vibration; during the first period, vibration affected the same LR pathway as nocodazole, while during the second period, vibration affected the integrity of the epithelial barrier; both are required for normal LR patterning. Our results indicate that low frequency vibrations disrupt two steps in the early LR pathway: the orientation of the LR axis with the other two axes, and the amplification/restriction of downstream LR signals to asymmetric organs.

  14. Allan deviation analysis of financial return series

    Science.gov (United States)

    Hernández-Pérez, R.

    2012-05-01

    We perform a scaling analysis for the return series of different financial assets applying the Allan deviation (ADEV), which is used in the time and frequency metrology to characterize quantitatively the stability of frequency standards since it has demonstrated to be a robust quantity to analyze fluctuations of non-stationary time series for different observation intervals. The data used are opening price daily series for assets from different markets during a time span of around ten years. We found that the ADEV results for the return series at short scales resemble those expected for an uncorrelated series, consistent with the efficient market hypothesis. On the other hand, the ADEV results for absolute return series for short scales (first one or two decades) decrease following approximately a scaling relation up to a point that is different for almost each asset, after which the ADEV deviates from scaling, which suggests that the presence of clustering, long-range dependence and non-stationarity signatures in the series drive the results for large observation intervals.

  15. Solar radiation pressure and deviations from Keplerian orbits

    Energy Technology Data Exchange (ETDEWEB)

    Kezerashvili, Roman Ya. [Physics Department, New York City College of Technology, the City University of New York, Brooklyn, NY 11201 (United States); Vazquez-Poritz, Justin F. [Physics Department, New York City College of Technology, City University of New York, Brooklyn, NY 11201 (United States)], E-mail: jporitz@gmail.com

    2009-05-04

    Newtonian gravity and general relativity give exactly the same expression for the period of an object in circular orbit around a static central mass. However, when the effects of the curvature of spacetime and solar radiation pressure are considered simultaneously for a solar sail propelled satellite, there is a deviation from Kepler's third law. It is shown that solar radiation pressure affects the period of this satellite in two ways: by effectively decreasing the solar mass, thereby increasing the period, and by enhancing the effects of other phenomena, potentially rendering some of them detectable. In particular, we consider deviations from Keplerian orbits due to spacetime curvature, frame dragging from the rotation of the sun, the oblateness of the sun, a possible net electric charge of the sun, and a very small positive cosmological constant.

  16. Differential processing of melodic, rhythmic and simple tone deviations in musicians--an MEG study.

    Science.gov (United States)

    Lappe, Claudia; Lappe, Markus; Pantev, Christo

    2016-01-01

    Rhythm and melody are two basic characteristics of music. Performing musicians have to pay attention to both, and avoid errors in either aspect of their performance. To investigate the neural processes involved in detecting melodic and rhythmic errors from auditory input we tested musicians on both kinds of deviations in a mismatch negativity (MMN) design. We found that MMN responses to a rhythmic deviation occurred at shorter latencies than MMN responses to a melodic deviation. Beamformer source analysis showed that the melodic deviation activated superior temporal, inferior frontal and superior frontal areas whereas the activation pattern of the rhythmic deviation focused more strongly on inferior and superior parietal areas, in addition to superior temporal cortex. Activation in the supplementary motor area occurred for both types of deviations. We also recorded responses to similar pitch and tempo deviations in a simple, non-musical repetitive tone pattern. In this case, there was no latency difference between the MMNs and cortical activation was smaller and mostly limited to auditory cortex. The results suggest that prediction and error detection of musical stimuli in trained musicians involve a broad cortical network and that rhythmic and melodic errors are processed in partially different cortical streams. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Effect of density deviations of concrete on its attenuation efficiency

    International Nuclear Information System (INIS)

    Szymendera, L.; Wincel, K.; Blociszewski, S.; Kordyasz, D.; Sobolewska, I.

    In the work, the influence of concrete density deviation on shield thickness and total dose ratio outside the reactor shield, has--on the basis of numerical analysis--been considered. It has been noticed the possibility of introducing flexible corrections--without additional shielding calculation--to the design thickness of the shield. It has been also found that in common cases of shield design, where any necessity of minimizing the shield thickness does not exist, the tendency to minimize the value of this deviation is hardly substantiable

  18. Improved iterative oscillation tests for first-order deviating differential equations

    Directory of Open Access Journals (Sweden)

    George E. Chatzarakis

    2018-01-01

    Full Text Available In this paper, improved oscillation conditions are established for the oscillation of all solutions of differential equations with non-monotone deviating arguments and nonnegative coefficients. They lead to a procedure that checks for oscillations by iteratively computing \\(\\lim \\sup\\ and \\(\\lim \\inf\\ on terms recursively defined on the equation's coefficients and deviating argument. This procedure significantly improves all known oscillation criteria. The results and the improvement achieved over the other known conditions are illustrated by two examples, numerically solved in MATLAB.

  19. HIT'91 (prospective, co-operative study for the treatment of malignant brain tumors in childhood): accuracy and acute toxicity of the irradiation of the craniospinal axis

    International Nuclear Information System (INIS)

    Kortmann, R.D.; Timmermann, B.; Bamberg, M.; Kuehl, J.; Willich, N.; Flentje, M.; Meisner, C.

    1999-01-01

    Background: It was the aim of the quality control program of the randomized trial HIT '91 (intensive chemotherapy before irradiation versus maintenance chemotherapy after irradiation) to assess prospectively the quality of neuroaxis irradiation with respect to the protocol guidelines and to evaluate acute toxicity with respect to treatment arm. Patients, Materials and Methods: Data of 134 patients undergoing irradiation of the craniospinal axis were available. Positioning aids, shielding techniques, treatment machines, choice of energy, total dose and fractionation were evaluated. A total of 651 simulation and verification films were analyzed to assess the coverage of the clinical target volume (whole brain, posterior fossa, sacral nerve roots) and deviations of field alignment between simulation and verification of first treatment. Field matching between whole brain and adjacent cranial spinal fields was analyzed with respect to site and width of junction. Acute maximal side effects were evaluated according to a modified WHO score for neurotoxicity, infections, skin, mucosa and myelotoxicity. Results: In 91.3% of patients contemporary positioning aids and individualized shielding techniques were used to assure a reproducible treatment. In 98 patients (73.1%) linear accelerators and in 36 patients (26.8%) 60 Cobalt machines were used. Single and total dose were administered according to the protocol guidelines in more than 90% of patients. In 20.2% of patients the cribriform plate, in 1.4% the middle cranial fossa and in 21.1% the posterior fossa and in 4.5% the 2nd sacral segment were incompletely encompassed by the treatment portals. Ninety-five percent of deviations of field alignment were less than 13.0 mm (whole brain) and 12 mm (cranial spinal field) with a random error between 4.9 and 7.6 mm (whole brain) and 6.9 mm and 9.9 mm (spinal canal), respectively. In 77.5% of patients the junctions between whole brain and cranial spinal fields were placed without a

  20. Single axis controlled hybrid magnetic bearing for left ventricular assist device: hybrid core and closed magnetic circuit.

    Science.gov (United States)

    da Silva, Isaias; Horikawa, Oswaldo; Cardoso, Jose R; Camargo, Fernando A; Andrade, Aron J P; Bock, Eduardo G P

    2011-05-01

    In previous studies, we presented main strategies for suspending the rotor of a mixed-flow type (centrifugal and axial) ventricular assist device (VAD), originally presented by the Institute Dante Pazzanese of Cardiology (IDPC), Brazil. Magnetic suspension is achieved by the use of a magnetic bearing architecture in which the active control is executed in only one degree of freedom, in the axial direction of the rotor. Remaining degrees of freedom, excepting the rotation, are restricted only by the attraction force between pairs of permanent magnets. This study is part of a joint project in development by IDPC and Escola Politecnica of São Paulo University, Brazil. This article shows advances in that project, presenting two promising solutions for magnetic bearings. One solution uses hybrid cores as electromagnetic actuators, that is, cores that combine iron and permanent magnets. The other solution uses actuators, also of hybrid type, but with the magnetic circuit closed by an iron core. After preliminary analysis, a pump prototype has been developed for each solution and has been tested. For each prototype, a brushless DC motor has been developed as the rotor driver. Each solution was evaluated by in vitro experiments and guidelines are extracted for future improvements. Tests have shown good results and demonstrated that one solution is not isolated from the other. One complements the other for the development of a single-axis-controlled, hybrid-type magnetic bearing for a mixed-flow type VAD. © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  1. On the value of geometry-based models for left ventricular volumetry in magnetic resonance imaging and electron beam tomography: a Bland-Altman analysis

    International Nuclear Information System (INIS)

    Reiter, Gert; Reiter, Ursula; Rienmueller, Rainer; Gagarina, Nina; Ryabikin, Alexander

    2004-01-01

    Objective: Methodological comparison of ellipsoid model-based approaches and Simpson method to evaluate left ventricular volumetric parameters by magnetic resonance (MR) and electron beam tomography (EBT) and analysis of the origin of possible discrepancies. Methods and material: 100 subjects (87 patients, 13 healthy volunteers) were studied in MR in various cardiac views and EBT long axis view to determine left ventricular volumes and masses by applying (rotational) ellipsoid and Simpson model. Observer variation and method agreement was quantified by means of variance component and Bland-Altman analysis. Results: Simpson approach showed smaller observer variability than all ellipsoid approaches. All geometry-based models gave smaller left ventricular volumes than Simpson approach, the bias in mass determination was minimal. Whereas high correlation coefficients (typically 0.85-0.95) for left ventricular volume and mass measurements indicated satisfying correspondence between methods, large 95% limits of agreement made a transfer of results for single subjects between Simpson and ellipsoid approaches difficult and between different geometry-based models almost impossible. Because 95% limits of agreement and observer variability of geometry-based approaches were of equal order, the latter could be identified as main limiting factor of methodological agreement. Conclusion: MR Simpson approach is superior to all ellipsoid model-based approaches, because observer variability is smaller

  2. Design and analysis of control charts for standard deviation with estimated parameters

    NARCIS (Netherlands)

    Schoonhoven, M.; Riaz, M.; Does, R.J.M.M.

    2011-01-01

    This paper concerns the design and analysis of the standard deviation control chart with estimated limits. We consider an extensive range of statistics to estimate the in-control standard deviation (Phase I) and design the control chart for real-time process monitoring (Phase II) by determining the

  3. [Roaming through methodology. XXXVIII. Common misconceptions involving standard deviation and standard error

    NARCIS (Netherlands)

    Mokkink, H.G.A.

    2002-01-01

    Standard deviation and standard error have a clear mutual relationship, but at the same time they differ strongly in the type of information they supply. This can lead to confusion and misunderstandings. Standard deviation describes the variability in a sample of measures of a variable, for instance

  4. 14 CFR 121.360 - Ground proximity warning-glide slope deviation alerting system.

    Science.gov (United States)

    2010-01-01

    ... deviation alerting system. 121.360 Section 121.360 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... Equipment Requirements § 121.360 Ground proximity warning-glide slope deviation alerting system. (a) No... system that meets the performance and environmental standards of TSO-C92 (available from the FAA, 800...

  5. Dyscalculia, Dysgraphia, and Left-Right Confusion from a Left Posterior Peri-Insular Infarct

    Directory of Open Access Journals (Sweden)

    S. Bhattacharyya

    2014-01-01

    Full Text Available The Gerstmann syndrome of dyscalculia, dysgraphia, left-right confusion, and finger agnosia is generally attributed to lesions near the angular gyrus of the dominant hemisphere. A 68-year-old right-handed woman presented with sudden difficulty completing a Sudoku grid and was found to have dyscalculia, dysgraphia, and left-right confusion. Magnetic resonance imaging (MRI showed a focus of abnormal reduced diffusivity in the left posterior insula and temporoparietal operculum consistent with acute infarct. Gerstmann syndrome from an insular or peri-insular lesion has not been described in the literature previously. Pathological and functional imaging studies show connections between left posterior insular region and inferior parietal lobe. We postulate that the insula and operculum lesion disrupted key functional networks resulting in a pseudoparietal presentation.

  6. Dyscalculia, dysgraphia, and left-right confusion from a left posterior peri-insular infarct.

    Science.gov (United States)

    Bhattacharyya, S; Cai, X; Klein, J P

    2014-01-01

    The Gerstmann syndrome of dyscalculia, dysgraphia, left-right confusion, and finger agnosia is generally attributed to lesions near the angular gyrus of the dominant hemisphere. A 68-year-old right-handed woman presented with sudden difficulty completing a Sudoku grid and was found to have dyscalculia, dysgraphia, and left-right confusion. Magnetic resonance imaging (MRI) showed a focus of abnormal reduced diffusivity in the left posterior insula and temporoparietal operculum consistent with acute infarct. Gerstmann syndrome from an insular or peri-insular lesion has not been described in the literature previously. Pathological and functional imaging studies show connections between left posterior insular region and inferior parietal lobe. We postulate that the insula and operculum lesion disrupted key functional networks resulting in a pseudoparietal presentation.

  7. Apraxia in left-handers.

    Science.gov (United States)

    Goldenberg, Georg

    2013-08-01

    In typical right-handed patients both apraxia and aphasia are caused by damage to the left hemisphere, which also controls the dominant right hand. In left-handed subjects the lateralities of language and of control of the dominant hand can dissociate. This permits disentangling the association of apraxia with aphasia from that with handedness. Pantomime of tool use, actual tool use and imitation of meaningless hand and finger postures were examined in 50 consecutive left-handed subjects with unilateral hemisphere lesions. There were three aphasic patients with pervasive apraxia caused by left-sided lesions. As the dominant hand is controlled by the right hemisphere, they constitute dissociations of apraxia from handedness. Conversely there were also three patients with pervasive apraxia caused by right brain lesions without aphasia. They constitute dissociations of apraxia from aphasia. Across the whole group of patients dissociations from handedness and from aphasia were observed for all manifestations of apraxia, but their frequency depended on the type of apraxia. Defective pantomime and defective tool use occurred rarely without aphasia, whereas defective imitation of hand, but not finger, postures was more frequent after right than left brain damage. The higher incidence of defective imitation of hand postures in right brain damage was mainly due to patients who had also hemi-neglect. This interaction alerts to the possibility that the association of right hemisphere damage with apraxia has to do with spatial aptitudes of the right hemisphere rather than with its control of the dominant left hand. Comparison with data from right-handed patients showed no differences between the severity of apraxia for imitation of hand or finger postures, but impairment on pantomime of tool use was milder in apraxic left-handers than in apraxic right-handers. This alleviation of the severity of apraxia corresponded with a similar alleviation of the severity of aphasia as

  8. RITA: The reinvented triple axis spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Mason, T.E. [Toronto Univ., ON (Canada). Dept. of Physics; Clausen, K.N.; Aeppli, G.; McMorrow, D.R.; Kjems, J.K. [Risoe National Lab., Roskilde (Denmark)

    1995-11-01

    Risoe National Laboratory was reported to be in the process of developing a new spectrometer design, RITA, based on the triple axis design. The spectrometer will attempt to incorporate more recent innovations such as multilayer supermirrors and microstrip proportional counters into a rethinking of the triple-axis spectrometer. By optimizing the beam optics, using supermirrors and extending the analyser to map regions of (Q, {omega}) space using an array of independently controllable pyrolytic graphite crystals focussed on an area detector, it was hoped that the efficiency of single-crystal inelastic experiments could be increased by as much as a factor of 20. 7 figs., 20 refs.

  9. Equilibrium studies of helical axis stellarators

    International Nuclear Information System (INIS)

    Hender, T.C.; Carreras, B.A.; Garcia, L.; Harris, J.H.; Rome, J.A.; Cantrell, J.L.; Lynch, V.E.

    1984-01-01

    The equilibrium properties of helical axis stellarators are studied with a 3-D equilibrium code and with an average method (2-D). The helical axis ATF is shown to have a toroidally dominated equilibrium shift and good equilibria up to at least 10% peak beta. Low aspect ratio heliacs, with relatively large toroidal shifts, are shown to have low equilibrium beta limits (approx. 5%). Increasing the aspect ratio and number of field periods proportionally is found to improve the equilibrium beta limit. Alternatively, increasing the number of field periods at fixed aspect ratio which raises and lowers the toroidal shift improves the equilibrium beta limit

  10. Geometry of river networks. I. Scaling, fluctuations, and deviations

    International Nuclear Information System (INIS)

    Dodds, Peter Sheridan; Rothman, Daniel H.

    2001-01-01

    This paper is the first in a series of three papers investigating the detailed geometry of river networks. Branching networks are a universal structure employed in the distribution and collection of material. Large-scale river networks mark an important class of two-dimensional branching networks, being not only of intrinsic interest but also a pervasive natural phenomenon. In the description of river network structure, scaling laws are uniformly observed. Reported values of scaling exponents vary, suggesting that no unique set of scaling exponents exists. To improve this current understanding of scaling in river networks and to provide a fuller description of branching network structure, here we report a theoretical and empirical study of fluctuations about and deviations from scaling. We examine data for continent-scale river networks such as the Mississippi and the Amazon and draw inspiration from a simple model of directed, random networks. We center our investigations on the scaling of the length of a subbasin's dominant stream with its area, a characterization of basin shape known as Hack's law. We generalize this relationship to a joint probability density, and provide observations and explanations of deviations from scaling. We show that fluctuations about scaling are substantial, and grow with system size. We find strong deviations from scaling at small scales which can be explained by the existence of a linear network structure. At intermediate scales, we find slow drifts in exponent values, indicating that scaling is only approximately obeyed and that universality remains indeterminate. At large scales, we observe a breakdown in scaling due to decreasing sample space and correlations with overall basin shape. The extent of approximate scaling is significantly restricted by these deviations, and will not be improved by increases in network resolution

  11. Vertical axis wind turbines: a survey and bibliography

    Energy Technology Data Exchange (ETDEWEB)

    Abramovich, H

    1987-01-01

    The stimulus for the development of modern, big wind turbines has been the world-wide oil crisis during the seventies. Although the horizontal axis wind turbines (HAWT) was the most popular type of wind turbine the Darrieus vertical axis wind turbine (VAWT) has been recognized as a machine with competitive economic potential. The state of the art of the VAWT is reviewed. The wind turbine carrying the name of Darrieus was first proposed by the French inventor in 1925. His original patent covered a range of vertical-axis configurations but the term 'Darrieus' is now generally associated with the curved-blade geometry. In 1966 two researchers at the Canadian NRC again raised the idea of both the straight and curved-blade versions of the Darrieus VAWT.

  12. A Note on Standard Deviation and Standard Error

    Science.gov (United States)

    Hassani, Hossein; Ghodsi, Mansoureh; Howell, Gareth

    2010-01-01

    Many students confuse the standard deviation and standard error of the mean and are unsure which, if either, to use in presenting data. In this article, we endeavour to address these questions and cover some related ambiguities about these quantities.

  13. THE LIMITED EFFECT OF COINCIDENT ORIENTATION ON THE CHOICE OF INTRINSIC AXIS (.).

    Science.gov (United States)

    Li, Jing; Su, Wei

    2015-06-01

    The allocentric system computes and represents general object-to-object spatial relationships to provide a spatial frame of reference other than the egocentric system. The intrinsic frame-of-reference system theory, which suggests people learn the locations of objects based upon an intrinsic axis, is important in research about the allocentric system. The purpose of the current study was to determine whether the effect of coincident orientation on the choice of intrinsic axis was limited. Two groups of participants (24 men, 24 women; M age = 24 yr., SD = 2) encoded different spatial layouts in which the objects shared the coincident orientation of 315° and 225° separately at learning perspective (0°). The response pattern of partial-scene-recognition task following learning reflected different strategies for choosing the intrinsic axis under different conditions. Under the 315° object-orientation condition, the objects' coincident orientation was as important as the symmetric axis in the choice of the intrinsic axis. However, participants were more likely to choose the symmetric axis as the intrinsic axis under the 225° object-orientation condition. The results suggest the effect of coincident orientation on the choice of intrinsic axis is limited.

  14. Relationship and significance of gait deviations associated with limb length discrepancy: A systematic review.

    Science.gov (United States)

    Khamis, Sam; Carmeli, Eli

    2017-09-01

    Controversy still exists as to the clinical significance of leg length discrepancy (LLD) in spite of the fact that further evidence has been emerging regarding the relationship between several clinical conditions and LLD. The objectives of our study were to review the available research with regard to LLD as a cause of clinically significant gait deviations, to determine if there is a relationship between the magnitude of LLD and the presence of gait deviations and to identify the most common gait deviations associated with LLD. In line with the PRISMA guidelines, a literature search was carried out throughout the Medline, CINAHL and EMBASE databases. Twelve articles met the predetermined inclusion criteria and were included in the review. Quality assessment using the Methodological Index for Non-Randomized Studies (MINORS) scale was completed for all included studies. Two main methodologies were found in 4 studies evaluating gait asymmetry in patients or healthy participants with anatomic LLD and 8 studies evaluating gait deviations while simulating LLD by employing artificial lifts of 1-5cm on healthy subjects. A significant relationship was found between anatomic LLD and gait deviation. Evidence suggests that gait deviations may occur with discrepancies of >1cm, with greater impact seen as the discrepancy increases. Compensatory strategies were found to occur in both the shorter and longer limb, throughout the lower limb. As the discrepancy increases, more compensatory strategies occur. Sagittal plane deviations seem to be the most effective deviations, although, frontal plane compensations also occur in the pelvis, hip and foot. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. 40 CFR 60.2780 - What must I include in the deviation report?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false What must I include in the deviation... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and... the deviation report? In each report required under § 60.2775, for any pollutant or parameter that...

  16. 40 CFR 60.2958 - What must I include in the deviation report?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false What must I include in the deviation... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Operator Training and Qualification Recordkeeping and Reporting § 60.2958 What must I include in the deviation report? In each report...

  17. Aerodynamic Optimization of Airfoil Profiles for Small Horizontal Axis Wind Turbines

    Directory of Open Access Journals (Sweden)

    Ali Cemal Benim

    2018-04-01

    Full Text Available The purpose of this study is the development of an automated two-dimensional airfoil shape optimization procedure for small horizontal axis wind turbines (HAWT, with an emphasis on high thrust and aerodynamically stable performance. The procedure combines the Computational Fluid Dynamics (CFD analysis with the Response Surface Methodology (RSM, the Biobjective Mesh Adaptive Direct Search (BiMADS optimization algorithm and an automatic geometry and mesh generation tool. In CFD analysis, a Reynolds Averaged Numerical Simulation (RANS is applied in combination with a two-equation turbulence model. For describing the system behaviour under alternating wind conditions, a number of CFD 2D-RANS-Simulations with varying Reynolds numbers and wind angles are performed. The number of cases is reduced by the use of RSM. In the analysis, an emphasis is placed upon the role of the blade-to-blade interaction. The average and the standard deviation of the thrust are optimized by a derivative-free optimization algorithm to define a Pareto optimal set, using the BiMADS algorithm. The results show that improvements in the performance can be achieved by modifications of the blade shape and the present procedure can be used as an effective tool for blade shape optimization.

  18. FEMORAL NECK FRACTURES GARDEN I AND II: EVALUATION OF THE DEVIATION IN LATERAL VIEW.

    Science.gov (United States)

    Leonhardt, Natália Zalc; Melo, Lucas da Ponte; Nordon, David Gonçalves; Silva, Fernando Brandão de Andrade E; Kojima, Kodi Edson; Silva, Jorge Santos

    2017-01-01

    To evaluate the rate of deviation in the lateral radiographic incidence in patients with femoral neck fracture classified as non-diverted in the anteroposterior view (Garden I and II). Nineteen selected patients with femoral neck fractures classified as Garden I and II were retrospectively evaluated, estimating the degree of deviation in the lateral view. Fifteen cases (79%) presented deviations in lateral view, with a mean of 18.6 degrees (±15.5). Most fractures of the femoral neck classified as Garden I and II present some degree of posterior deviation in the X-ray lateral view. Level of Evidence III, Retrospective Comparative Study.

  19. Measurement Axis Searching Model for Terrestrial Laser Scans Registration

    Directory of Open Access Journals (Sweden)

    Shaoxing Hu

    2016-01-01

    Full Text Available Nowadays, terrestrial Lidar scans can cover rather a large area; the point densities are strongly varied because of the line-of-sight measurement principle in potential overlaps with scans taken from different viewpoints. Most of the traditional methods focus on registration algorithm and ignore searching model. Sometimes the traditional methods are directly used to align two point clouds; a large critically unsolved problem of the large biases will be created in areas distant from the overlaps while the local overlaps are often aligned well. So a novel measurement axis searching model (MASM has been proposed in this paper. The method includes four steps: (1 the principal axis fitting, (2 the measurement axis generation, (3 low-high-precision search, and (4 result generation. The principal axis gives an orientation to the point cloud; the search scope is limited by the measurement axis. The point cloud orientation can be adjusted gradually until the achievement of the global optimum using low- and high-precision search. We perform some experiments with simulated point clouds and real terrestrial laser scans. The results of simulated point clouds have shown the processing steps of our method, and the results of real terrestrial laser scans have shown the sensitivity of the approach with respect to the indoor and outdoor scenes.

  20. Method for solving fully fuzzy linear programming problems using deviation degree measure

    Institute of Scientific and Technical Information of China (English)

    Haifang Cheng; Weilai Huang; Jianhu Cai

    2013-01-01

    A new ful y fuzzy linear programming (FFLP) prob-lem with fuzzy equality constraints is discussed. Using deviation degree measures, the FFLP problem is transformed into a crispδ-parametric linear programming (LP) problem. Giving the value of deviation degree in each constraint, the δ-fuzzy optimal so-lution of the FFLP problem can be obtained by solving this LP problem. An algorithm is also proposed to find a balance-fuzzy optimal solution between two goals in conflict: to improve the va-lues of the objective function and to decrease the values of the deviation degrees. A numerical example is solved to il ustrate the proposed method.

  1. Left ventricular filling under elevated left atrial pressure

    Science.gov (United States)

    Gaddam, Manikantam; Samaee, Milad; Santhanakrishnan, Arvind

    2017-11-01

    Left atrial pressure (LAP) is elevated in diastolic dysfunction, where left ventricular (LV) filling is impaired due to increase in ventricular stiffness. The impact of increasing LAP and LV stiffness on intraventricular filling hemodynamics remains unclear. We conducted particle image velocimetry and hemodynamics measurements in a left heart simulator (LHS) under increasing LAP and LV stiffness at a heart rate of 70 bpm. The LHS consisted of a flexible-walled LV physical model fitted within a fluid-filled chamber. LV wall motion was generated by a piston pump that imparted pressure fluctuations in the chamber. Resistance and compliance elements in the flow loop were adjusted to obtain bulk physiological hemodynamics in the least stiff LV model. Two LV models of increasing stiffness were subsequently tested under unchanged loop settings. LAP was varied between 5-20 mm Hg for each LV model, by adjusting fluid level in a reservoir upstream of the LV. For constant LV stiffness, increasing LAP lowered cardiac output (CO), while ejection fraction (EF) and E/A ratio were increased. For constant LAP, increasing LV stiffness lowered CO and EF, and increased E/A ratio. The implications of these altered hemodynamics on intraventricular filling vortex characteristics will be presented.

  2. 40 CFR 60.2220 - What must I include in the deviation report?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false What must I include in the deviation... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for... Recordkeeping and Reporting § 60.2220 What must I include in the deviation report? In each report required under...

  3. 40 CFR 60.3053 - What must I include in the deviation report?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false What must I include in the deviation... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emission Guidelines and Compliance... Model Rule-Recordkeeping and Reporting § 60.3053 What must I include in the deviation report? In each...

  4. The manufacturing and metrology of off-axis mirrors

    Science.gov (United States)

    Penzkofer, Karlheinz; Rascher, Rolf; Küpper, Lutz; Liebl, Johannes

    2015-10-01

    Especially in the area of the large mirror manufacturing only a few manufacturers are capable to produce optical surfaces of high quality. Therefore a deterministic process should be developed in the project IFasO. In the field of telescope optics off-axis optical systems are becoming increasingly important. These systems try to avoid an obstructing of the incoming light by moving the secondary mirror out of the primary mirror's optical axis. This advantage leads to an increasing market for this type of optical surface. Until now off-axis mirrors were difficult or almost impossible to produce. With the processes developed in IFasO, high quality mirrors become possible. For this reason, this paper describes the manufacturing of off-axis surfaces and its problems. The mirror production used in the project IFasO is based on the specific design of the CNC center developed by the company Optotech. This center UPG2000 is capable of grinding, polishing, sagitta measurement and interferometric measurement in one mounting of the specimen. Usually a large optics has to be transported during their manufacturing after every individual process step. There is always a risk of damage of the specimen. The exact orientation of the surface relatively to the tool position is also required. This takes a huge amount of time and makes up most of the production time. In this presentation the use of UPG2000 and the next steps within the process development are described. In the current status the manufacturing of large off-axis elements with a PV < λ/10 rms is reproducible.

  5. Characterization of a multi-axis ion chamber array.

    Science.gov (United States)

    Simon, Thomas A; Kozelka, Jakub; Simon, William E; Kahler, Darren; Li, Jonathan; Liu, Chihray

    2010-11-01

    The aim of this work was to characterize a multi-axis ion chamber array (IC PROFILER; Sun Nuclear Corporation, Melbourne, FL, USA) that has the potential to simplify the acquisition of LINAC beam data. The IC PROFILER (or panel) measurement response was characterized with respect to radiation beam properties, including dose, dose per pulse, pulse rate frequency (PRF), and energy. Panel properties were also studied, including detector-calibration stability, power-on time, backscatter dependence, and the panel's agreement with water tank measurements [profiles, fractional depth dose (FDD), and output factors]. The panel's relative deviation was typically within (+/-) 1% of an independent (or nominal) response for all properties that were tested. Notable results were (a) a detectable relative field shape change of approximately 1% with linear accelerator PRF changes; (b) a large range in backscatter thickness had a minimal effect on the measured dose distribution (typically less than 1%); (c) the error spread in profile comparison between the panel and scanning water tank (Blue Phantom, CC13; IBA Schwarzenbruck, DE) was approximately (+/-) 0.75%. The ability of the panel to accurately reproduce water tank profiles, FDDs, and output factors is an indication of its abilities as a dosimetry system. The benefits of using the panel versus a scanning water tank are less setup time and less error susceptibility. The same measurements (including device setup and breakdown) for both systems took 180 min with the water tank versus 30 min with the panel. The time-savings increase as the measurement load is increased.

  6. Design and implementation of five-axis transformation function in CNC system

    Directory of Open Access Journals (Sweden)

    Wang Feng

    2014-04-01

    Full Text Available To implement five-axis functions in CNC system, based on domestic system Lan Tian series, an improved design method for the system software structure is proposed in this paper. The numerical control kernel of CNC system is divided into the task layer and the motion layer. A five-axis transformation unit is integrated into the motion layer. After classifying five-axis machines into different types and analyzing their geometry information, the five-axis kinematic library is designed according to the abstract factory pattern. Furthermore, by taking CA spindle-tilting machine as an example, the forward and the inverse kinematic transformations are deduced. Based on the new software architecture and the five-axis kinematic library, algorithms of RTCP (rotation tool center point control and 3D radius compensation for end-milling are designed and realized. The milling results show that, with five-axis functions based on such software structure, the instructions with respect to the cutter’s position and orientation can be directly carried out in the CNC system.

  7. Comparison of changes in the transverse dental axis between patients with skeletal Class III malocclusion and facial asymmetry treated by orthognathic surgery with and without presurgical orthodontic treatment.

    Science.gov (United States)

    Song, Han-Sol; Choi, Sung-Hwan; Cha, Jung-Yul; Lee, Kee-Joon; Yu, Hyung-Seog

    2017-07-01

    To evaluate transverse skeletal and dental changes, including those in the buccolingual dental axis, between patients with skeletal Class III malocclusion and facial asymmetry after bilateral intraoral vertical ramus osteotomy with and without presurgical orthodontic treatment. This retrospective study included 29 patients with skeletal Class III malocclusion and facial asymmetry including menton deviation > 4 mm from the midsagittal plane. To evaluate changes in transverse skeletal and dental variables (i.e., buccolingual inclination of the upper and lower canines and first molars), the data for 16 patients who underwent conventional orthognathic surgery (CS) were compared with those for 13 patients who underwent preorthodontic orthognathic surgery (POGS), using three-dimensional computed tomography at initial examination, 1 month before surgery, and at 7 days and 1 year after surgery. The 1-year postsurgical examination revealed no significant changes in the postoperative transverse dental axis in the CS group. In the POGS group, the upper first molar inclined lingually on both sides (deviated side, -1.8° ± 2.8°, p = 0.044; nondeviated side, -3.7° ± 3.3°, p = 0.001) and the lower canine inclined lingually on the nondeviated side (4.0° ± 5.4°, p = 0.022) during postsurgical orthodontic treatment. There were no significant differences in the skeletal and dental variables between the two groups at 1 year after surgery. POGS may be a clinically acceptable alternative to CS as a treatment to achieve stable transverse axes of the dentition in both arches in patients with skeletal Class III malocclusion and facial asymmetry.

  8. Hazards and preventive measures of well deviation in well construction of in-situ leaching

    International Nuclear Information System (INIS)

    Zou Wenjie; Chen Shihe

    2006-01-01

    Whether the in-situ leaching method is successful depends on the quality of borehole engineering to a great extent. There are lots of factors that affect the quality, and the well deviation is one of notable problems. The hazards and causes of the well deviation are analyzed. The preventive measures and the methods of rectifying the deviation are put forward. (authors)

  9. Impact of inter- and intrafraction deviations and residual set-up errors on PTV margins. Different alignment techniques in 3D conformal prostate cancer radiotherapy

    International Nuclear Information System (INIS)

    Langsenlehner, T.; Doeller, C.; Winkler, P.; Kapp, K.S.; Galle, G.

    2013-01-01

    The aim of this work was to analyze interfraction and intrafraction deviations and residual set-up errors (RSE) after online repositioning to determine PTV margins for 3 different alignment techniques in prostate cancer radiotherapy. The present prospective study included 44 prostate cancer patients with implanted fiducials treated with three-dimensional (3D) conformal radiotherapy. Daily localization was based on skin marks followed by marker detection using kilovoltage (kV) imaging and subsequent patient repositioning. Additionally, in-treatment megavoltage (MV) images were obtained for each treatment field. In an off-line analysis of 7,273 images, interfraction prostate motion, RSE after marker-based prostate localization, prostate position during each treatment session, and the effect of treatment time on intrafraction deviations were analyzed to evaluate PTV margins. Margins accounting for interfraction deviation, RSE and intrafraction motion were 14.1, 12.9, and 15.1 mm in anterior-posterior (AP), superior-inferior (SI), and left-right (LR) direction for skin mark alignment and 9.6, 8.7, and 2.6 mm for bony structure alignment, respectively. Alignment to implanted markers required margins of 4.6, 2.8, and 2.5 mm. As margins to account for intrafraction motion increased with treatment prolongation PTV margins could be reduced to 3.9, 2.6, and 2.4 mm if treatment time was ≤ 4 min. With daily online correction and repositioning based on implanted fiducials, a significant reduction of PTV margins can be achieved. The use of an optimized workflow with faster treatment techniques such as volumetric modulated arc techniques (VMAT) could allow for a further decrease. (orig.)

  10. Standard deviation index for stimulated Brillouin scattering suppression with different homogeneities.

    Science.gov (United States)

    Ran, Yang; Su, Rongtao; Ma, Pengfei; Wang, Xiaolin; Zhou, Pu; Si, Lei

    2016-05-10

    We present a new quantitative index of standard deviation to measure the homogeneity of spectral lines in a fiber amplifier system so as to find the relation between the stimulated Brillouin scattering (SBS) threshold and the homogeneity of the corresponding spectral lines. A theoretical model is built and a simulation framework has been established to estimate the SBS threshold when input spectra with different homogeneities are set. In our experiment, by setting the phase modulation voltage to a constant value and the modulation frequency to different values, spectral lines with different homogeneities can be obtained. The experimental results show that the SBS threshold increases negatively with the standard deviation of the modulated spectrum, which is in good agreement with the theoretical results. When the phase modulation voltage is confined to 10 V and the modulation frequency is set to 80 MHz, the standard deviation of the modulated spectrum equals 0.0051, which is the lowest value in our experiment. Thus, at this time, the highest SBS threshold has been achieved. This standard deviation can be a good quantitative index in evaluating the power scaling potential in a fiber amplifier system, which is also a design guideline in suppressing the SBS to a better degree.

  11. Effects of age, sex and arm on the precision of arm position sense-left-arm superiority in healthy right-handers.

    Science.gov (United States)

    Schmidt, Lena; Depper, Lena; Kerkhoff, Georg

    2013-01-01

    Position sense is an important proprioceptive ability. Disorders of arm position sense (APS) often occur after unilateral stroke, and are associated with a negative functional outcome. In the present study we assessed horizontal APS by measuring angular deviations from a visually defined target separately for each arm in a large group of healthy subjects. We analyzed the accuracy and instability of horizontal APS as a function of age, sex and arm. Subjects were required to specify verbally the position of their unseen arm on a 0-90° circuit by comparing the current position with the target position indicated by a LED lamp, while the arm was passively moved by the examiner. Eighty-seven healthy subjects participated in the study, ranging from 20 to 77 years, subdivided into three age groups. The results revealed that APS was not a function of age or sex, but was significantly better in the non-dominant (left) arm in absolute errors (AE) but not in constant errors (CE) across all age groups of right-handed healthy subjects. This indicates a right-hemisphere superiority for left APS in right-handers and neatly fits to the more frequent and more severe left-sided body-related deficits in patients with unilateral stroke (i.e. impaired APS in left spatial neglect, somatoparaphrenia) or in individuals with abnormalities of the right cerebral hemisphere. These clinical issues will be discussed.

  12. Wavelength selection method with standard deviation: application to pulse oximetry.

    Science.gov (United States)

    Vazquez-Jaccaud, Camille; Paez, Gonzalo; Strojnik, Marija

    2011-07-01

    Near-infrared spectroscopy provides useful biological information after the radiation has penetrated through the tissue, within the therapeutic window. One of the significant shortcomings of the current applications of spectroscopic techniques to a live subject is that the subject may be uncooperative and the sample undergoes significant temporal variations, due to his health status that, from radiometric point of view, introduce measurement noise. We describe a novel wavelength selection method for monitoring, based on a standard deviation map, that allows low-noise sensitivity. It may be used with spectral transillumination, transmission, or reflection signals, including those corrupted by noise and unavoidable temporal effects. We apply it to the selection of two wavelengths for the case of pulse oximetry. Using spectroscopic data, we generate a map of standard deviation that we propose as a figure-of-merit in the presence of the noise introduced by the living subject. Even in the presence of diverse sources of noise, we identify four wavelength domains with standard deviation, minimally sensitive to temporal noise, and two wavelengths domains with low sensitivity to temporal noise.

  13. Theory of coherent c-axis Josephson tunneling between layered superconductors

    International Nuclear Information System (INIS)

    Arnold, G. B.; Klemm, R. A.

    2000-01-01

    We calculate exactly the Josephson current for c-axis coherent tunneling between two layered superconductors, each with internal coherent tight-binding intra- and interlayer quasiparticle dispersions. Our results also apply when one or both of the superconductors is a bulk material, and include the usually neglected effects of surface states. For weak tunneling, our results reduce to our previous results derived using the tunneling Hamiltonian. Our results are also correct for strong tunneling. However, the c-axis tunneling expressions of Tanaka and Kashiwaya are shown to be incorrect in any limit. In addition, we consider the c-axis coherent critical current between two identical layered superconductors twisted an angle φ 0 about the c axis with respect to each other. Regardless of the order-parameter symmetry, our coherent tunneling results using a tight-binding intralayer quasiparticle dispersion are inconsistent with the recent c-axis twist bicrystal Bi 2 Sr 2 CaCu 2 O 8+δ twist junction experiments of Li et al. [Li et al., Phys. Rev. Lett. 83, 4160 (1999)]. (c) 2000 The American Physical Society

  14. Axis-switching of a micro-jet

    Science.gov (United States)

    Cabaleiro, Juan Martin; Aider, Jean-Luc

    2014-03-01

    In this study, it is shown that free microjets can undergo complex transitions similar to large-scale free jets despite relatively low Reynolds numbers. Using an original experimental method allowing for the 3D reconstruction of the instantaneous spatial organization of the microjet, the axis-switching of a micro-jet is observed for the first time. This is the first experimental evidence of such complex phenomena for free micro-jets. Combining these experimental results with Direct Numerical Simulations it is shown that the mechanism responsible for the axis-switching is the deformation of a micro-vortex ring due to induction by the corner vortices, as it occurs in large scale non-circular jets.

  15. Calibration of three-axis magnetometers with differential evolution algorithm

    International Nuclear Information System (INIS)

    Pang, Hongfeng; Zhang, Qi; Wang, Wei; Wang, Junya; Li, Ji; Luo, Shitu; Wan, Chengbiao; Chen, Dixiang; Pan, Mengchun; Luo, Feilu

    2013-01-01

    The accuracy of three-axis magnetometers is influenced by different scale and bias of each axis and nonorthogonality between axes. One limitation of traditional iteration methods is that initial parameters influence the calibration, thus leading to the local optimal or wrong results. In this paper, a new method is proposed to calibrate three-axis magnetometers. To employ this method, a nonmagnetic rotation platform, a proton magnetometer, a DM-050 three-axis magnetometer and the differential evolution (DE) algorithm are used. The performance of this calibration method is analyzed with simulation and experiment. In simulation, the calibration results of DE, unscented Kalman filter (UKF), recursive least squares (RLS) and genetic algorithm (GA) are compared. RMS error using DE is least, which is reduced from 81.233 nT to 1.567 nT. Experimental results show that comparing with UKF, RLS and GA, the DE algorithm has not only the least calibration error but also the best robustness. After calibration, RMS error is reduced from 68.914 nT to 2.919 nT. In addition, the DE algorithm is not sensitive to initial parameters, which is an important advantage compared with traditional iteration algorithms. The proposed algorithm can avoid the troublesome procedure to select suitable initial parameters, thus it can improve the calibration performance of three-axis magnetometers. - Highlights: • The calibration results and robustness of UKF, GA, RLS and DE algorithm are analyzed. • Calibration error of DE is the least in simulation and experiment. • Comparing with traditional calibration algorithms, DE is not sensitive to initial parameters. • It can improve the calibration performance of three-axis magnetometers

  16. Computation of standard deviations in eigenvalue calculations

    International Nuclear Information System (INIS)

    Gelbard, E.M.; Prael, R.

    1990-01-01

    In Brissenden and Garlick (1985), the authors propose a modified Monte Carlo method for eigenvalue calculations, designed to decrease particle transport biases in the flux and eigenvalue estimates, and in corresponding estimates of standard deviations. Apparently a very similar method has been used by Soviet Monte Carlo specialists. The proposed method is based on the generation of ''superhistories'', chains of histories run in sequence without intervening renormalization of the fission source. This method appears to have some disadvantages, discussed elsewhere. Earlier numerical experiments suggest that biases in fluxes and eigenvalues are negligibly small, even for very small numbers of histories per generation. Now more recent experiments, run on the CRAY-XMP, tend to confirm these earlier conclusions. The new experiments, discussed in this paper, involve the solution of one-group 1D diffusion theory eigenvalue problems, in difference form, via Monte Carlo. Experiments covered a range of dominance ratios from ∼0.75 to ∼0.985. In all cases flux and eigenvalue biases were substantially smaller than one standard deviation. The conclusion that, in practice, the eigenvalue bias is negligible has strong theoretical support. (author)

  17. Dynamic transitions in a model of the hypothalamic-pituitary-adrenal axis

    Science.gov (United States)

    Čupić, Željko; Marković, Vladimir M.; Maćešić, Stevan; Stanojević, Ana; Damjanović, Svetozar; Vukojević, Vladana; Kolar-Anić, Ljiljana

    2016-03-01

    Dynamic properties of a nonlinear five-dimensional stoichiometric model of the hypothalamic-pituitary-adrenal (HPA) axis were systematically investigated. Conditions under which qualitative transitions between dynamic states occur are determined by independently varying the rate constants of all reactions that constitute the model. Bifurcation types were further characterized using continuation algorithms and scale factor methods. Regions of bistability and transitions through supercritical Andronov-Hopf and saddle loop bifurcations were identified. Dynamic state analysis predicts that the HPA axis operates under basal (healthy) physiological conditions close to an Andronov-Hopf bifurcation. Dynamic properties of the stress-control axis have not been characterized experimentally, but modelling suggests that the proximity to a supercritical Andronov-Hopf bifurcation can give the HPA axis both, flexibility to respond to external stimuli and adjust to new conditions and stability, i.e., the capacity to return to the original dynamic state afterwards, which is essential for maintaining homeostasis. The analysis presented here reflects the properties of a low-dimensional model that succinctly describes neurochemical transformations underlying the HPA axis. However, the model accounts correctly for a number of experimentally observed properties of the stress-response axis. We therefore regard that the presented analysis is meaningful, showing how in silico investigations can be used to guide the experimentalists in understanding how the HPA axis activity changes under chronic disease and/or specific pharmacological manipulations.

  18. Topography of the accessory left gastric artery (ALGA) analyzed by CT angiography from the left hepatic artery

    International Nuclear Information System (INIS)

    Shioyama, Yasukazu; Takasaka, Isao; Onaya, Hiroaki

    2003-01-01

    To avoid gastric complications when we perform transcatheter treatment via left hepatic artery, we analyzed the topography of ALGA (accessory left gastric artery) by left hepatic arteriography and CT angiography from left hepatic artery. Six hundred seventy eight cases of CT angiography were performed between 1995 and 2000. Among them, selective left hepatic arteriography was done in 85 cases. We analyzed the frequency and the course of ALGA on the hepatic angiogram and CT angiogram. ALGA were identified in eighteen (21.2 %) of the 85 cases. We classified them into eleven cases of the proximal type and six cases of the distal type. When ALGA bifurcated from the left hepatic artery very close to the bifurcation of A2 (dorsolateral branch) and A3 (ventrolateral branch), we classified them as the distal type on hepatic angiogram. On the other hand, when ALGA bifurcated from the left hepatic artery apart from the bifurcation of A2 and A3 they were classified as the proximal type. In one rare case ALGA originated from the dorsolateral branch of the left hepatic artery. ALGA were classified as the distal and proximal types. Distal type of ALGA often overlapped dorsolateral branch of the left hepatic artery, and it was sometimes difficult to notice the existence of them. We should check the existence of ALGA on the arterial phase of dynamic CT before we plan to make a transcatheter treatment from the left hepatic artery. Then we can avoid gastric complications caused by a transcatheter treatment from the left hepatic artery. (author)

  19. Analysis of some fuel characteristics deviations and their influence over WWER-440 fuel cycle design

    International Nuclear Information System (INIS)

    Stoyanova, I.; Kamenov, K.

    2001-01-01

    The aim of this study is to estimate the influence of some deviations in WWER-440 fuel assemblies (FA) characteristics upon fuel core design. A large number of different fresh fuel assemblies with enrichment of 3.5 t % are examined related to the enrichment, mass of initial metal Uranium and assembly shroud thickness. Infinite multiplication factor (Kinf) in fuel assembly has been calculated by HELIOS spectral code for basic assembly and for different FA with deviation of a single parameter. The effects from single parameter deviation (enrichment) and from two parameter deviations (enrichment and wall thickness) on the neutron-physics characteristics of the core are estimated for different fuel assemblies. Relatively week burnup dependence on Kinf is observed as result of deviation in the enrichment of the fuel and in the wall thickness of the assembly. An assessment of a FA single and two parameter deviations effects on design fuel cycle duration and relative power peaking factor is also considers in the paper. As a final conclusion can be settled that the maximum relative shortness of fuel cycle can be observed in the case of two FA parameters deviations

  20. Left Atrial Decompression by Percutaneous Left Atrial Venting Cannula Insertion during Venoarterial Extracorporeal Membrane Oxygenation Support

    Directory of Open Access Journals (Sweden)

    Ha Eun Kim

    2016-06-01

    Full Text Available Patients with venoarterial extracorporeal membrane oxygenation (ECMO frequently suffer from pulmonary edema due to left ventricular dysfunction that accompanies left heart dilatation, which is caused by left atrial hypertension. The problem can be resolved by left atrium (LA decompression. We performed a successful percutaneous LA decompression with an atrial septostomy and placement of an LA venting cannula in a 38-month-old child treated with venoarterial ECMO for acute myocarditis.

  1. The Molecular Differentiation of Anatomically Paired Left and Right Mantles of the Pacific Oyster Crassostrea gigas.

    Science.gov (United States)

    Wei, Lei; Xu, Fei; Wang, Yuzhi; Cai, Zhongqiang; Yu, Wenchao; He, Cheng; Jiang, Qiuyun; Xu, Xiqiang; Guo, Wen; Wang, Xiaotong

    2018-03-28

    Left-right (L-R) asymmetry is controlled by gene regulation pathways for the L-R axis, and in vertebrates, the gene Pitx2 in TGF-β signaling pathway plays important roles in the asymmetrical formation of organs. However, less is known about the asymmetries of anatomically identical paired organs, as well as the transcriptional regulation mechanism of the gene Pitx in invertebrates. Here, we report the molecular biological differences between the left and right mantles of an invertebrate, the Pacific oyster Crassostrea gigas, and propose one possible mechanism underlying those differences. RNA sequencing (RNA-seq) analysis indicated that the paired organs showed different gene expression patterns, suggesting possible functional differences in shell formation, pheromone signaling, nerve conduction, the stress response, and other physiological processes. RNA-seq and real-time qPCR analysis indicated high right-side expression of the Pitx homolog (cgPitx) in oyster mantle, supporting a conserved role for Pitx in controlling asymmetry. Methylation-dependent restriction-site associated DNA sequencing (MethylRAD) identified a methylation site in the promoter region of cgPitx and showed significantly different methylation levels between the left and right mantles. This is the first report, to our knowledge, of such a difference in methylation in spiralians, and it was further confirmed in 18 other individuals by using a pyrosequencing assay. The miRNome analysis and the TGF-β receptor/Smad inhibition experiment further supported that several genes in TGF-β signaling pathway may be related with the L/R asymmetry of oyster mantles. These results suggested that the molecular differentiation of the oyster's paired left and right mantles is significant, TGF-β signaling pathway could be involved in establishing or maintaining the asymmetry, and the cgPitx gene as one of genes in this pathway; the different methylation levels in its promoter regions between L/R mantles was

  2. Social aspects of left-handedness

    Directory of Open Access Journals (Sweden)

    Belojević Goran

    2010-01-01

    Full Text Available Throughout human history left-handedness has been considered as sinful. It has been associated with the devil, weakness, female gender, unhealthiness, evil, something that has to be turned to a “good” - right side by force. Left-handedness is being more and more acceptable at rational level, but in everyday life it is still considered to be unusual if someone writes with the left hand. Lessening of the number of lefthanders is associated with ageing. There are about 13% lefthanders among people in twenties and less than 1% lefthanders among those in eighties. This finding may be explaned with more pronounced socio-cultural pressure on left-handed people in the past, compared to nowadays. On the other hand, this may also support the hypothesis about a reduced life span of lefthanded people. With cross-exercising of left-handedness, certain typical characteristics and behavioral patterns appear in these people. This was a sort of provoked behavior and an attack on the integrity of an emotional attitude toward oneself. Stuttering may also appear as a consequence of unsuccessful cross-exercising of left-handedness. The hypothesis about left-handedness as an advantage is supported with the reports about relatively more lefthanders in some specific groups such as: mathematicians, sculptors, architects, painters, musicians, actors, tennis players, as well as famous army commanders and rulers.

  3. Transmission-type angle deviation microscopy

    International Nuclear Information System (INIS)

    Chiu, M.-H.; Lai, C.-W.; Tan, C.-T.; Lai, C.-F.

    2008-01-01

    We present a new microscopy technique that we call transmission angle deviation microscopy (TADM). It is based on common-path heterodyne interferometry and geometrical optics. An ultrahigh sensitivity surface plasmon resonance (SPR) angular sensor is used to expand dynamic measurement ranges and to improve the axial resolution in three-dimensional optical microscopy. When transmitted light is incident upon a specimen, the beam converges or diverges because of refractive and/or surface height variations. Advantages include high axial resolution (∼32 nm), nondestructive and noncontact measurement, and larger measurement ranges (± 80 μm) for a numerical aperture of 0.21in a transparent measurement medium. The technique can be used without conductivity and pretreatment

  4. On asymptotically efficient simulation of large deviation probabilities.

    NARCIS (Netherlands)

    Dieker, A.B.; Mandjes, M.R.H.

    2005-01-01

    ABSTRACT: Consider a family of probabilities for which the decay is governed by a large deviation principle. To find an estimate for a fixed member of this family, one is often forced to use simulation techniques. Direct Monte Carlo simulation, however, is often impractical, particularly if the

  5. International asset pricing under segmentation and PPP deviations

    NARCIS (Netherlands)

    Chaieb, I.; Errunza, V.

    2007-01-01

    We analyze the impact of both purchasing power parity (PPP) deviations and market segmentation on asset pricing and investor's portfolio holdings. The freely traded securities command a world market risk premium and an inflation risk premium. The securities that can be held by only a subset of

  6. The standard deviation method: data analysis by classical means and by neural networks

    International Nuclear Information System (INIS)

    Bugmann, G.; Stockar, U. von; Lister, J.B.

    1989-08-01

    The Standard Deviation Method is a method for determining particle size which can be used, for instance, to determine air-bubble sizes in a fermentation bio-reactor. The transmission coefficient of an ultrasound beam through a gassy liquid is measured repetitively. Due to the displacements and random positions of the bubbles, the measurements show a scatter whose standard deviation is dependent on the bubble-size. The precise relationship between the measured standard deviation, the transmission and the particle size has been obtained from a set of computer-simulated data. (author) 9 figs., 5 refs

  7. Left ventricular assist device implantation via left thoracotomy: alternative to repeat sternotomy.

    Science.gov (United States)

    Pierson, Richard N; Howser, Renee; Donaldson, Terri; Merrill, Walter H; Dignan, Rebecca J; Drinkwater, Davis C; Christian, Karla G; Butler, Javed; Chomsky, Don; Wilson, John R; Clark, Rick; Davis, Stacy F

    2002-03-01

    Repeat sternotomy for left ventricular assist device insertion may result in injury to the right heart or patent coronary grafts, complicating intraoperative and postoperative management. In 4 critically ill patients, left thoracotomy was used as an alternative to repeat sternotomy. Anastomosis of the outflow conduit to the descending thoracic aorta provided satisfactory hemodynamic support.

  8. Impact of age and sex on normal left heart structure and function.

    Science.gov (United States)

    Hagström, Linn; Henein, Michael Y; Karp, Kjell; Waldenström, Anders; Lindqvist, Per

    2017-11-01

    Accurate age- and sex-related normal reference values of ventricular structure and function are important to determine the level of dysfunction in patients. The aim of this study therefore was to document normal age range sex-related measurements of LV structural and functional measurements to serve such purpose. We evaluated left ventricular structure and function in 293 healthy subjects between 20 and 90 years with equally distributed gender. Doppler echocardiography was used including measure of both systolic and diastolic functions. Due to systolic LV function, only long axis function correlated with age (r = 0·55, P<0·01) and the correlation was stronger in females. Concerning diastolic function, there was a strong age correlation in all parameters used (r = 0·40-0·74, P<0·001). Due to LV structural changes over age, females showed a larger reduction in end-diastolic volumes, but no or trivial difference in wall thickness after the age of 60 years. Age is associated with significant normal changes in left ventricular structure and function, which should be considered when deciding on normality. These changes are related to systemic arterial changes as well as body stature, thus reflecting overall body ageing process. Furthermore, normal cardiac ageing in females might partly explain the higher prevalence of heart failure with preserved ejection in females. © 2016 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  9. DARHT Axis-I Diode Simulations II: Geometrical Scaling

    Energy Technology Data Exchange (ETDEWEB)

    Ekdahl, Carl A. Jr. [Los Alamos National Laboratory

    2012-06-14

    Flash radiography of large hydrodynamic experiments driven by high explosives is a venerable diagnostic technique in use at many laboratories. Many of the largest hydrodynamic experiments study mockups of nuclear weapons, and are often called hydrotests for short. The dual-axis radiography for hydrodynamic testing (DARHT) facility uses two electron linear-induction accelerators (LIA) to produce the radiographic source spots for perpendicular views of a hydrotest. The first of these LIAs produces a single pulse, with a fixed {approx}60-ns pulsewidth. The second axis LIA produces as many as four pulses within 1.6-{micro}s, with variable pulsewidths and separation. There are a wide variety of hydrotest geometries, each with a unique radiographic requirement, so there is a need to adjust the radiographic dose for the best images. This can be accomplished on the second axis by simply adjusting the pulsewidths, but is more problematic on the first axis. Changing the beam energy or introducing radiation attenuation also changes the spectrum, which is undesirable. Moreover, using radiation attenuation introduces significant blur, increasing the effective spot size. The dose can also be adjusted by changing the beam kinetic energy. This is a very sensitive method, because the dose scales as the {approx}2.8 power of the energy, but it would require retuning the accelerator. This leaves manipulating the beam current as the best means for adjusting the dose, and one way to do this is to change the size of the cathode. This method has been proposed, and is being tested. This article describes simulations undertaken to develop scaling laws for use as design tools in changing the Axis-1 beam current by changing the cathode size.

  10. Velocity measurement of model vertical axis wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, D.A.; McWilliam, M. [Waterloo Univ., ON (Canada). Dept. of Mechanical Engineering

    2006-07-01

    An increasingly popular solution to future energy demand is wind energy. Wind turbine designs can be grouped according to their axis of rotation, either horizontal or vertical. Horizontal axis wind turbines have higher power output in a good wind regime than vertical axis turbines and are used in most commercial class designs. Vertical axis Savonius-based wind turbine designs are still widely used in some applications because of their simplistic design and low wind speed performance. There are many design variables that must be considered in order to optimize the power output in a given wind regime in a typical wind turbine design. Using particle image velocimetry, a study of the air flow around five different model vertical axis wind turbines was conducted in a closed loop wind tunnel. A standard Savonius design with two semi-circular blades overlapping, and two variations of this design, a deep blade and a shallow blade design were among the turbine models included in this study. It also evaluated alternate designs that attempt to increase the performance of the standard design by allowing compound blade curvature. Measurements were collected at a constant phase angle and also at random rotor orientations. It was found that evaluation of the flow patterns and measured velocities revealed consistent and stable flow patterns at any given phase angle. Large scale flow structures are evident in all designs such as vortices shed from blade surfaces. An important performance parameter was considered to be the ability of the flow to remain attached to the forward blade and redirect and reorient the flow to the following blade. 6 refs., 18 figs.

  11. Management of Contract Waivers and Deviations for Defense Systems

    National Research Council Canada - National Science Library

    1998-01-01

    This report is the fourth and final in a series of reports resulting from our audit of management of contract waivers and deviations for Defense systems and summarizes our overall evaluation. Report...

  12. Imaging performance of annular apertures. VI - Limitations by optical surface deviations

    Science.gov (United States)

    Tschunko, Hubert F. A.

    1987-01-01

    The performance of optical systems is limited by imperfect optical surfaces that degrade the images below the level set by wave theoretical limits. The central irradiance functions are derived for slit and circular apertures with five distributions of wavefront errors and for a range of maximal wavefront deviations. For practical frequency of occurrence distributions of wavefront deviations, the point spread and the image energy integral functions are determined. Practical performances of optical systems are derived and performance limits discussed.

  13. VARIATION IN THE OPENINGS (OSTIA OF LEFT PULMONARY VEINS INTO THE LEFT ATRIUM: A CASE REPORT

    Directory of Open Access Journals (Sweden)

    Sesi

    2015-03-01

    Full Text Available During early embryonic development, absorption of pulmonary venous network by the left primitive atrial chamber results in opening of four pulmonary veins which drain independently into its chamber. The extent of absorption and hence, the number of pulmon ary veins which open into the left atrium, may vary. Here we report a variation in the opening of the Left upper (superior pulmonary vein into the Left atrium. A total of six openings observed

  14. [Study on physical deviation factors on laser induced breakdown spectroscopy measurement].

    Science.gov (United States)

    Wan, Xiong; Wang, Peng; Wang, Qi; Zhang, Qing; Zhang, Zhi-Min; Zhang, Hua-Ming

    2013-10-01

    In order to eliminate the deviation between the measured LIBS spectral line and the standard LIBS spectral line, and improve the accuracy of elements measurement, a research of physical deviation factors in laser induced breakdown spectroscopy technology was proposed. Under the same experimental conditions, the relationship of ablated hole effect and spectral wavelength was tested, the Stark broadening data of Mg plasma laser induced breakdown spectroscopy with sampling time-delay from 1.00 to 3.00 micros was also studied, thus the physical deviation influences such as ablated hole effect and Stark broadening could be obtained while collecting the spectrum. The results and the method of the research and analysis can also be applied to other laser induced breakdown spectroscopy experiment system, which is of great significance to improve the accuracy of LIBS elements measuring and is also important to the research on the optimum sampling time-delay of LIBS.

  15. Large deviations for solutions to stochastic recurrence equations under Kesten's condition

    DEFF Research Database (Denmark)

    Buraczewski, Dariusz; Damek, Ewa; Mikosch, Thomas Valentin

    2013-01-01

    In this paper we prove large deviations results for partial sums constructed from the solution to a stochastic recurrence equation. We assume Kesten’s condition [17] under which the solution of the stochastic recurrence equation has a marginal distribution with power law tails, while the noise...... sequence of the equations can have light tails. The results of the paper are analogs of those obtained by A.V. and S.V. Nagaev [21, 22] in the case of partial sums of iid random variables. In the latter case, the large deviation probabilities of the partial sums are essentially determined by the largest...... step size of the partial sum. For the solution to a stochastic recurrence equation, the magnitude of the large deviation probabilities is again given by the tail of the maximum summand, but the exact asymptotic tail behavior is also influenced by clusters of extreme values, due to dependencies...

  16. Effect of left ventricular diastolic dysfunction on left atrial appendage function and thrombotic potential in nonvalvular atrial fibrillation.

    Science.gov (United States)

    Demirçelik, Muhammed Bora; Çetin, Mustafa; Çiçekcioğlu, Hülya; Uçar, Özgül; Duran, Mustafa

    2014-05-01

    We aimed to investigate effects of left ventricular diastolic dysfunction on left atrial appendage functions, spontaneous echo contrast and thrombus formation in patients with nonvalvular atrial fibrillation. In 58 patients with chronic nonvalvular atrial fibrilation and preserved left ventricular systolic function, left atrial appendage functions, left atrial spontaneous echo contrast grading and left ventricular diastolic functions were evaluated using transthoracic and transoesophageal echocardiogram. Patients divided in two groups: Group D (n=30): Patients with diastolic dysfunction, Group N (n=28): Patients without diastolic dysfunction. Categorical variables in two groups were evaluated with Pearson's chi-square or Fisher's exact test. The significance of the lineer correlation between the degree of spontaneous echo contrast (SEC) and clinical measurements was evaluated with Spearman's correlation analysis. Peak pulmonary vein D velocity of the Group D was significantly higher than the Group N (p=0.006). However, left atrial appendage emptying velocity, left atrial appendage lateral wall velocity, peak pulmonary vein S, pulmonary vein S/D ratio were found to be significantly lower in Group D (p=0.028, patrial appendage emptying, filling, pulmonary vein S/D levels and lateral wall velocities respectively (r=-0.438, r=-0.328, r=-0.233, r=-0.447). Left atrial appendage emptying, filling, pulmonary vein S/D levels and lateral wall velocities were significantly lower in SEC 2-3-4 than SEC 1 (p=0.003, p=0.029, patrial fibrillation and preserved left ventricular ejection fraction, left atrial appendage functions are decreased in patients with left ventricular diastolic dysfunction. Left ventricular diastolic dysfunction may constitute a potential risk for formation of thrombus and stroke.

  17. Assessment of left ventricular mass in sequential studies with cine MR imaging

    International Nuclear Information System (INIS)

    Tomei, E.; Semelka, R.; Wagner, S.; Mayo, J.; Chatterjee, K.; Parmley, W.W.; O'Sullivan, M.; Wolfe, C.L.; Caputo, G.; Higgins, C.B.

    1989-01-01

    The aim of this study was to measure left ventricular (LV) mass in 11 healthy volunteers, 10 patients with dilated cardiomyopathy, and eight patients with LV hypertrophy (LVH), using two sequential studies to compare the characteristics of LV mass in the same subject and in different clinical situations. All subjects underwent short- axis cine MR imaging at 1.5 T. Each subject had two separate studies: the healthy volunteers within 6 months and those with cardiac disease within 1 week. Measurements (both end- systolic and end-diastolic) included LV mass, LV mass index, and wall thickness. LV mass was substantially increased in both DCM and LVH. The interstudy variability for end- systolic and end-diastolic mass was 5.2% and 3.8%, respectively, for healthy volunteers, 5.2% and 4.0% for LVH, and 3.8% and 6.1% for DCM. The low variability indicates the reproducibility of this technique in sequential studies when no change is expected

  18. [Localization and registration of the hinge axis in black Africans].

    Science.gov (United States)

    Assi, K D; N'Guessan, K S; N'Dindin, C; Bamba, A

    2003-06-01

    The study of the cinematic method using "SAM" and "Quick Axis of FAG" added to mandibular condyle palpation for the hinge axis limited points, show that the Black Africans mandibular condyle rotation axis position is higher (3.5 mm) and backer (2 mm) than the Caucasians. The axial points are located to between 11 and 12 mm in front of the tragus and between 7 and 8 mm below on the perpendicular line to the furrow defining the tragus superior side to the Ectocanthus.

  19. Right colon cancer: Left behind.

    Science.gov (United States)

    Gervaz, P; Usel, M; Rapiti, E; Chappuis, P; Neyroud-Kaspar, I; Bouchardy, C

    2016-09-01

    Prognosis of colon cancer (CC) has steadily improved during the past three decades. This trend, however, may vary according to proximal (right) or distal (left) tumor location. We studied if improvement in survival was greater for left than for right CC. We included all CC recorded at the Geneva population-based registry between 1980 and 2006. We compared patients, tumor and treatment characteristics between left and right CC by logistic regression and compared CC specific survival by Cox models taking into account putative confounders. We also compared changes in survival between CC location in early and late years of observation. Among the 3396 CC patients, 1334 (39%) had right-sided and 2062 (61%) left-sided tumors. In the early 1980s, 5-year specific survival was identical for right and left CCs (49% vs. 48%). During the study period, a dramatic improvement in survival was observed for patients with left-sided cancers (Hazard ratio [HR]: 0.42, 95% confidence interval [CI]: 0.29-0.62, p colon cancer patients, those with right-sided lesions have by far the worse prognosis. Change of strategic management in this subgroup is warranted. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Usefulness of Epicardial Area in the Short Axis to Identify Elevated Left Ventricular Mass in Men.

    Science.gov (United States)

    Fitzpatrick, Jesse K; Cohen, Beth E; Rosenblatt, Andrew; Shaw, Richard E; Schiller, Nelson B

    2018-06-15

    Left ventricular (LV) hypertrophy is strongly associated with increased cardiovascular morbidity and mortality. The 2-dimensional LV mass algorithms suffer from measurement variability that can lead to misclassification of patients with LV hypertrophy as normal, or vice versa. Among the 4 echocardiographic measurements required by the 2-dimensional LV mass algorithms, epicardial and endocardial area have the lowest interobserver variation and could be used to corroborate LV mass calculations. We sought cut-off values that are able to discriminate between elevated and normal LV mass based on endocardial or epicardial area alone. Using data from 664 men enrolled in the Mind Your Heart Study, we calculated the correlation of LV mass index with epicardial area and endocardial area. We then used receiver operator characteristic curves to identify epicardial and endocardial area cut-points that could discriminate subjects with normal LV mass and LV hypertrophy. LV mass index was more strongly correlated with epicardial area compared with endocardial area, r = 0.70 versus r = 0.27, respectively. Epicardial area had a significantly higher area under the receiver operator characteristic curve (p versus 0.63 (95% confidence interval 0.57 to 0.71). An epicardial area cut-point of ≥38.0 cm 2 corresponded to a sensitivity of 95.0% and specificity of 54.4% for detecting LV hypertrophy. In conclusion, epicardial area showed promise as a method of rapid screening for LV hypertrophy and could be used to validate formal LV mass calculations. Copyright © 2018 Elsevier Inc. All rights reserved.