WorldWideScience

Sample records for left atrial receptors

  1. Left atrial appendage occlusion

    Directory of Open Access Journals (Sweden)

    Ahmad Mirdamadi

    2013-01-01

    Full Text Available Left atrial appendage (LAA occlusion is a treatment strategy to prevent blood clot formation in atrial appendage. Although, LAA occlusion usually was done by catheter-based techniques, especially percutaneous trans-luminal mitral commissurotomy (PTMC, it can be done during closed and open mitral valve commissurotomy (CMVC, OMVC and mitral valve replacement (MVR too. Nowadays, PTMC is performed as an optimal management of severe mitral stenosis (MS and many patients currently are treated by PTMC instead of previous surgical methods. One of the most important contraindications of PTMC is presence of clot in LAA. So, each patient who suffers of severe MS is evaluated by Trans-Esophageal Echocardiogram to rule out thrombus in LAA before PTMC. At open heart surgery, replacement of the mitral valve was performed for 49-year-old woman. Also, left atrial appendage occlusion was done during surgery. Immediately after surgery, echocardiography demonstrates an echo imitated the presence of a thrombus in left atrial appendage area, although there was not any evidence of thrombus in pre-pump TEE. We can conclude from this case report that when we suspect of thrombus of left atrial, we should obtain exact history of previous surgery of mitral valve to avoid misdiagnosis clotted LAA, instead of obliterated LAA. Consequently, it can prevent additional evaluations and treatments such as oral anticoagulation and exclusion or postponing surgeries including PTMC.

  2. Occlusion of left atrial appendage in patients with atrial fibrillation

    Directory of Open Access Journals (Sweden)

    О. Н. Ганеева

    2015-10-01

    Full Text Available The article reviews a new method of prophylaxis of thromboembolitic complications, specifically occlusion of left atrial appendage, in patients with atrial fibrillation. Indications and contraindications for the procedure, as well as a step-by-step process of the intervention itself are described. Special emphasis is placed on the up-to-date evidence and the review of clinical trials.

  3. Left Atrial Decompression by Percutaneous Left Atrial Venting Cannula Insertion during Venoarterial Extracorporeal Membrane Oxygenation Support

    Directory of Open Access Journals (Sweden)

    Ha Eun Kim

    2016-06-01

    Full Text Available Patients with venoarterial extracorporeal membrane oxygenation (ECMO frequently suffer from pulmonary edema due to left ventricular dysfunction that accompanies left heart dilatation, which is caused by left atrial hypertension. The problem can be resolved by left atrium (LA decompression. We performed a successful percutaneous LA decompression with an atrial septostomy and placement of an LA venting cannula in a 38-month-old child treated with venoarterial ECMO for acute myocarditis.

  4. Echocardiographic study of left atrial myxoma

    Directory of Open Access Journals (Sweden)

    Dalal J

    1979-01-01

    Full Text Available Four cases of left atrial myxoma were diagnosed pre-operatively by echocardiography. All cases showed characteristic echocardio-graphic features of variegated shadows behind the mitral valve in diastole and within the left atrium in systole. In two cases the my-xomas were surgically removed and confirmed on histology. In one case the post-operative echocardiogram showed complete dis-appearance of the abnormal shadows. Echocardiography is the most reliable method today for the diagnosis of a myxoma.

  5. [Left versus bi-atrial radiofrequency ablation in the treatment of atrial fibrillation].

    Science.gov (United States)

    Wang, Jian-Gang; Meng, Xu; Li, Hui

    2008-11-25

    To evaluate the effectiveness of radiofrequency modified maze operation for the treatment of atrial fibrillation (AF) and compare the results of the left versus bi-atrial procedures. 305 patients of organic heart disease combined with AF, 117 males and 188 females, aged (53 +/- 10), that underwent cardiac valve operation (n = 293) and/or coronary artery bypass graft surgery (n = 14), received concomitant atrial fibrillation, bi-atrial (n = 160) or left atrial (n = 145) with a mean duration of (36 +/- 43) months. Follow-up was conducted for (28 +/- 5) (3 - 42) months. Thirteen patients (4.3%) died postoperatively: 7 died of multisystem and organ failure, 3 of low cardiac output, 1 of rupture of left ventricle, 1 of arrhythmia, and 1 of sudden death. During the follow-up, 1 patient died of heart failure, 1 of encephalorrhagia and 1 of unknown reason in the bi-atrial group. At the end of the procedure 223 patients (73.1%) had sinus rhythm, with a sinus rhythm rate of 66.9% (107/160) in the bi-atrial group, significant lower than that in the left atrial group (80.0%, 116/145, P bi-atrial group was 80.0%, not significantly different from that of the left atrial group (81.9%, P > 0.05). The Kaplan-Meier survival analysis showed there was no significant difference in the AF rhythm rate between these 2 groups (P = 0.33). Logistic regression analysis showed that the left atrial diameter of >/= 80 mm was an independent predictor of AF recurrence. Both the left and bi-atrial procedures are successful in terms of restoring sinus rhythm. Left atrial ablation in severe cases and where the incision of right atrium is not needed is a reasonable choice.

  6. Left Atrial 4D Blood Flow Dynamics and Hemostasis following Electrical Cardioversion of Atrial Fibrillation

    Directory of Open Access Journals (Sweden)

    Merih Cibis

    2017-12-01

    Full Text Available Background: Electrical cardioversion in patients with atrial fibrillation is followed by a transiently impaired atrial mechanical function, termed atrial stunning. During atrial stunning, a retained risk of left atrial thrombus formation exists, which may be attributed to abnormal left atrial blood flow patterns. 4D Flow cardiovascular magnetic resonance (CMR enables blood flow assessment from the entire three-dimensional atrial volume throughout the cardiac cycle. We sought to investigate left atrial 4D blood flow patterns and hemostasis during left atrial stunning and after left atrial mechanical function was restored.Methods: 4D Flow and morphological CMR data as well as blood samples were collected in fourteen patients at two time-points: 2–3 h (Time-1 and 4 weeks (Time-2 following cardioversion. The volume of blood stasis and duration of blood stasis were calculated. In addition, hemostasis markers were analyzed.Results: From Time-1 to Time-2: Heart rate decreased (61 ± 7 vs. 56 ± 8 bpm, p = 0.01; Maximum change in left atrial volume increased (8 ± 4 vs. 22 ± 15%, p = 0.009; The duration of stasis (68 ± 11 vs. 57 ± 8%, p = 0.002 and the volume of stasis (14 ± 9 vs. 9 ± 7%, p = 0.04 decreased; Thrombin-antithrombin complex (TAT decreased (5.2 ± 3.3 vs. 3.3 ± 2.2 μg/L, p = 0.008. A significant correlation was found between TAT and the volume of stasis (r2 = 0.69, p < 0.001 at Time-1 and between TAT and the duration of stasis (r2 = 0.34, p = 0.04 at Time-2.Conclusion: In this longitudinal study, left atrial multidimensional blood flow was altered and blood stasis was elevated during left atrial stunning compared to the restored left atrial mechanical function. The coagulability of blood was also elevated during atrial stunning. The association between blood stasis and hypercoagulability proposes that assessment of left atrial 4D flow can add to the pathophysiological understanding of thrombus formation during atrial fibrillation

  7. Left Atrial 4D Blood Flow Dynamics and Hemostasis following Electrical Cardioversion of Atrial Fibrillation

    Science.gov (United States)

    Cibis, Merih; Lindahl, Tomas L.; Ebbers, Tino; Karlsson, Lars O.; Carlhäll, Carl-Johan

    2017-01-01

    Background: Electrical cardioversion in patients with atrial fibrillation is followed by a transiently impaired atrial mechanical function, termed atrial stunning. During atrial stunning, a retained risk of left atrial thrombus formation exists, which may be attributed to abnormal left atrial blood flow patterns. 4D Flow cardiovascular magnetic resonance (CMR) enables blood flow assessment from the entire three-dimensional atrial volume throughout the cardiac cycle. We sought to investigate left atrial 4D blood flow patterns and hemostasis during left atrial stunning and after left atrial mechanical function was restored. Methods: 4D Flow and morphological CMR data as well as blood samples were collected in fourteen patients at two time-points: 2–3 h (Time-1) and 4 weeks (Time-2) following cardioversion. The volume of blood stasis and duration of blood stasis were calculated. In addition, hemostasis markers were analyzed. Results: From Time-1 to Time-2: Heart rate decreased (61 ± 7 vs. 56 ± 8 bpm, p = 0.01); Maximum change in left atrial volume increased (8 ± 4 vs. 22 ± 15%, p = 0.009); The duration of stasis (68 ± 11 vs. 57 ± 8%, p = 0.002) and the volume of stasis (14 ± 9 vs. 9 ± 7%, p = 0.04) decreased; Thrombin-antithrombin complex (TAT) decreased (5.2 ± 3.3 vs. 3.3 ± 2.2 μg/L, p = 0.008). A significant correlation was found between TAT and the volume of stasis (r2 = 0.69, p < 0.001) at Time-1 and between TAT and the duration of stasis (r2 = 0.34, p = 0.04) at Time-2. Conclusion: In this longitudinal study, left atrial multidimensional blood flow was altered and blood stasis was elevated during left atrial stunning compared to the restored left atrial mechanical function. The coagulability of blood was also elevated during atrial stunning. The association between blood stasis and hypercoagulability proposes that assessment of left atrial 4D flow can add to the pathophysiological understanding of thrombus formation during atrial fibrillation related

  8. Left atrial systolic force in hypertensive patients with left ventricular hypertrophy: the LIFE study

    DEFF Research Database (Denmark)

    Chinali, M.; Simone, G. de; Wachtell, K.

    2008-01-01

    In hypertensive patients without prevalent cardiovascular disease, enhanced left atrial systolic force is associated with left ventricular hypertrophy and increased preload. It also predicts cardiovascular events in a population with high prevalence of obesity. Relations between left atrial...... systolic force and left ventricular geometry and function have not been investigated in high-risk hypertrophic hypertensive patients. Participants in the Losartan Intervention For Endpoint reduction in hypertension echocardiography substudy without prevalent cardiovascular disease or atrial fibrillation (n...... = 567) underwent standard Doppler echocardiography. Left atrial systolic force was obtained from the mitral orifice area and Doppler mitral peak A velocity. Patients were divided into groups with normal or increased left atrial systolic force (>14.33 kdyn). Left atrial systolic force was high in 297...

  9. Effect of left ventricular diastolic dysfunction on left atrial appendage function and thrombotic potential in nonvalvular atrial fibrillation.

    Science.gov (United States)

    Demirçelik, Muhammed Bora; Çetin, Mustafa; Çiçekcioğlu, Hülya; Uçar, Özgül; Duran, Mustafa

    2014-05-01

    We aimed to investigate effects of left ventricular diastolic dysfunction on left atrial appendage functions, spontaneous echo contrast and thrombus formation in patients with nonvalvular atrial fibrillation. In 58 patients with chronic nonvalvular atrial fibrilation and preserved left ventricular systolic function, left atrial appendage functions, left atrial spontaneous echo contrast grading and left ventricular diastolic functions were evaluated using transthoracic and transoesophageal echocardiogram. Patients divided in two groups: Group D (n=30): Patients with diastolic dysfunction, Group N (n=28): Patients without diastolic dysfunction. Categorical variables in two groups were evaluated with Pearson's chi-square or Fisher's exact test. The significance of the lineer correlation between the degree of spontaneous echo contrast (SEC) and clinical measurements was evaluated with Spearman's correlation analysis. Peak pulmonary vein D velocity of the Group D was significantly higher than the Group N (p=0.006). However, left atrial appendage emptying velocity, left atrial appendage lateral wall velocity, peak pulmonary vein S, pulmonary vein S/D ratio were found to be significantly lower in Group D (p=0.028, patrial appendage emptying, filling, pulmonary vein S/D levels and lateral wall velocities respectively (r=-0.438, r=-0.328, r=-0.233, r=-0.447). Left atrial appendage emptying, filling, pulmonary vein S/D levels and lateral wall velocities were significantly lower in SEC 2-3-4 than SEC 1 (p=0.003, p=0.029, patrial fibrillation and preserved left ventricular ejection fraction, left atrial appendage functions are decreased in patients with left ventricular diastolic dysfunction. Left ventricular diastolic dysfunction may constitute a potential risk for formation of thrombus and stroke.

  10. Incisional left atrial isolation for ablation of atrial fibrillation in mitral valve surgery.

    Science.gov (United States)

    Graffigna, Angelo; Branzoli, Stefano; Sinelli, Stefano; Vigano, Mario

    2009-01-01

    The renewed interest in surgical techniques for atrial fibrillation (AF) limited to the left atrium has risen the importance of the original technique of left atrial isolation by means of surgical incision. Transmurality of lesions and cost containment are strong elements to be appreciated in this technique.

  11. Left ventricular filling under elevated left atrial pressure

    Science.gov (United States)

    Gaddam, Manikantam; Samaee, Milad; Santhanakrishnan, Arvind

    2017-11-01

    Left atrial pressure (LAP) is elevated in diastolic dysfunction, where left ventricular (LV) filling is impaired due to increase in ventricular stiffness. The impact of increasing LAP and LV stiffness on intraventricular filling hemodynamics remains unclear. We conducted particle image velocimetry and hemodynamics measurements in a left heart simulator (LHS) under increasing LAP and LV stiffness at a heart rate of 70 bpm. The LHS consisted of a flexible-walled LV physical model fitted within a fluid-filled chamber. LV wall motion was generated by a piston pump that imparted pressure fluctuations in the chamber. Resistance and compliance elements in the flow loop were adjusted to obtain bulk physiological hemodynamics in the least stiff LV model. Two LV models of increasing stiffness were subsequently tested under unchanged loop settings. LAP was varied between 5-20 mm Hg for each LV model, by adjusting fluid level in a reservoir upstream of the LV. For constant LV stiffness, increasing LAP lowered cardiac output (CO), while ejection fraction (EF) and E/A ratio were increased. For constant LAP, increasing LV stiffness lowered CO and EF, and increased E/A ratio. The implications of these altered hemodynamics on intraventricular filling vortex characteristics will be presented.

  12. Percutaneous left atrial appendage closure for stroke prevention

    DEFF Research Database (Denmark)

    De Backer, Ole; Loupis, Anastasia M; Ihlemann, Nikolaj

    2014-01-01

    INTRODUCTION: In atrial fibrillation (AF) patients with an increased stroke risk, oral anticoagulation (OAC) is the standard treatment for stroke prevention. However, this therapy carries a high risk of major bleeding. Percutaneous closure of the left atrial appendage (LAA) is suggested as an alt...

  13. Atorvastatin can ameliorate left atrial stunning induced by radiofrequency ablation for atrial fibrillation.

    Science.gov (United States)

    Xie, Ruiqin; Yang, Yingtao; Cui, Wei; Yin, Hongning; Zheng, Hongmei; Zhang, Jidong; You, Ling

    2017-09-01

    The objective of this study was to study the functional changes of the left atrium after radiofrequency ablation treatment for atrial fibrillation and the therapeutic effect of atorvastatin. Fifty-eight patients undergoing radiofrequency ablation for atrial fibrillation were randomly divided into non-atorvastatin group and atorvastatin group. Patients in the atorvastatin group were treated with atorvastatin 20 mg p.o. per night in addition to the conventional treatment of atrial fibrillation; patients in the non-atorvastatin group received conventional treatment of atrial fibrillation only. Echocardiography was performed before radiofrequency ablation operation and 1 week, 2 weeks, 3 weeks, and 4 weeks after operation. Two-dimensional ultrasound speckle tracking imaging system was used to measure the structural indexes of the left atrium. Results indicated that there was no significant change for indexes representing the structural status of the left atrium within a month after radiofrequency ablation (P > 0.05); however, there were significant changes for indexes representing the functional status of the left atrium. There were also significant changes in indexes reflecting left atrial strain status: the S and SRs of atorvastatin group were higher than those of non-atorvastatin group (P atorvastatin could improve left atrial function and shorten the duration of atrial stunning after radiofrequency ablation of atrial fibrillation.

  14. Assessment of left atrial volume and function

    DEFF Research Database (Denmark)

    Kühl, J Tobias; Lønborg, Jacob; Fuchs, Andreas

    2012-01-01

    dynamic LA volume changes. Conversely, cardiac magnetic resonance imaging (CMR) and multi-slice computed tomography (MSCT) appears more appropriate for such measures. We sought to determine the relationship between LA size assessed with TTE and LA size and function assessed with CMR and MSCT. Fifty......-four patients were examined 3 months post myocardial infarction with echocardiography, CMR and MSCT. Left atrial volumes and LA reservoir function were assessed by TTE. LA time-volume curves were determined and LA reservoir function (cyclic change and fractional change), passive emptying function (reservoir...... between CMR and MSCT, with a small to moderate bias in LA(max) (4.9 ± 10.4 ml), CC (3.1 ± 9.1 ml) and reservoir volume (3.4 ± 9.1 ml). TTE underestimates LA(max) with up to 32% compared with CMR and MSCT (P ...

  15. Left atrial size and function as predictors of new-onset of atrial fibrillation in patients with asymptomatic aortic stenosis

    DEFF Research Database (Denmark)

    Bang, Casper Niels Furbo; Dalsgaard, Morten; Greve, Anders

    2013-01-01

    Left atrial (LA) size and function change with chronically increased left ventricular (LV) filling pressures. It remains unclear whether these variations in LA parameters can predict new-onset atrial fibrillation (AF) in asymptomatic patients with aortic stenosis (AS).......Left atrial (LA) size and function change with chronically increased left ventricular (LV) filling pressures. It remains unclear whether these variations in LA parameters can predict new-onset atrial fibrillation (AF) in asymptomatic patients with aortic stenosis (AS)....

  16. The left atrium, atrial fibrillation, and the risk of stroke in hypertensive patients with left ventricular hypertrophy

    DEFF Research Database (Denmark)

    Wachtell, K.; Devereux, R.B.; Lyle, P.A.

    2008-01-01

    was superior to atenolol-based treatment for reducing new-onset AF and complications, especially stroke, associated with new-onset or pre-existing AF. Potential mechanisms of AF prevention by angiotensin receptor blockade supported by LIFE results include greater reduction in left atrial size and LV......The Losartan Intervention For Endpoint reduction in hypertension (LIFE) study provided extensive data on predisposing factors, consequences, and prevention of atrial fibrillation (AF) in patients with hypertension and left ventricular (LV) hypertrophy. Randomized losartan-based treatment...... hypertrophy. Differential effects of antihypertensive treatment on the left atrium and left ventricle may help prevent AF and reduce risk of stroke associated with hypertensive heart disease Udgivelsesdato: 2008/12...

  17. Mapping of the left-sided phrenic nerve course in patients undergoing left atrial catheter ablations.

    Science.gov (United States)

    Huemer, Martin; Wutzler, Alexander; Parwani, Abdul S; Attanasio, Philipp; Haverkamp, Wilhelm; Boldt, Leif-Hendrik

    2014-09-01

    Catheter ablation of atrial fibrillation has been associated with left-sided phrenic nerve palsy. Knowledge of the individual left phrenic nerve course therefore is essential to prevent nerve injury. The aim of this study was to test the feasibility of an intraprocedural pace mapping and reconstruction of the left phrenic nerve course and to characterize which anatomical areas are affected. In patients undergoing left atrial catheter ablation, a three-dimensional map of the left atrial anatomical structures was created. The left-sided phrenic nerve course was determined by high-output pace mapping and reconstructed in the map. In this study, 40 patients with atrial fibrillation or atrial tachycardias were included. Left phrenic nerve capture was observed in 23 (57.5%) patients. Phrenic nerve was captured in 22 (55%) patients inside the left atrial appendage, in 22 (55%) in distal parts, in 21 (53%) in medial parts, and in two (5%) in ostial parts of the appendage. In three (7.5%) patients, capture was found in the distal coronary sinus and in one (2.5%) patient in the left atrium near the left atrial appendage ostium. Ablation target was changed due to direct spatial relationship to the phrenic nerve in three (7.5%) patients. No phrenic nerve palsy was observed. Left-sided phrenic nerve capture was found inside and around the left atrial appendage in the majority of patients and additionally in the distal coronary sinus. Phrenic nerve mapping and reconstruction can easily be performed and should be considered prior catheter ablations in potential affected areas. ©2014 Wiley Periodicals, Inc.

  18. Transient left atrial dysfunction is a feature of Takotsubo syndrome

    DEFF Research Database (Denmark)

    Stiermaier, Thomas; Graf, Tobias; Möller, Christian

    2017-01-01

    BACKGROUND: Takotsubo syndrome (TTS) is characterized by a transient left and/or right ventricular dysfunction as a consequence of a distinctive pattern of regional wall motion abnormalities. However, a systematic evaluation of the left atrial (LA) function in patients with TTS is lacking. The ai...

  19. Anatomic relationship between left coronary artery and left atrium in patients undergoing atrial fibrillation ablation.

    Science.gov (United States)

    Anselmino, Matteo; Torri, Federica; Ferraris, Federico; Calò, Leonardo; Castagno, Davide; Gili, Sebastiano; Rovera, Chiara; Giustetto, Carla; Gaita, Fiorenzo

    2017-07-01

    Atrial fibrillation transcatheter ablation (TCA) is, within available atrial fibrillation rhythm control strategies, one of the most effective. To potentially improve ablation outcome in case of recurrent atrial fibrillation after a first procedure or in presence of structural myocardial disease, isolation of the pulmonary veins may be associated with extensive lesions within the left atrium. To avoid rare, but potentially life-threatening, complications, thorough knowledge and assessment of left atrium anatomy and its relation to structures in close proximity are, therefore, mandatory. Aim of the present study is to describe, by cardiac computed tomography, the anatomic relationship between aortic root, left coronary artery and left atrium in patients undergoing atrial fibrillation TCA. The cardiac computed tomography scan of 21 patients affected by atrial fibrillation was elaborated to segment left atrium, aortic root and left coronary artery from the surrounding structures and the following distances measured: left atrium and aortic root; left atrium roof and aortic root; left main coronary artery and left atrium; circumflex artery and left atrium appendage; and circumflex artery and mitral valve annulus. Above all, the median distance between left atrium and aortic root (1.9, 1.5-2.1 mm), and between circumflex artery and left atrium appendage ostium (3.0, 2.1-3.4 mm) were minimal (≤3 mm). None of measured distances significantly varied between patients presenting paroxysmal versus persistent atrial fibrillation. The anatomic relationship between left atrium and coronary arteries is extremely relevant when performing atrial fibrillation TCA by extensive lesions. Therefore, at least in the latter case, preablation imaging should be recommended to avoid rare, but potentially life-threatening, complications with the aim of an as well tolerated as possible procedure.

  20. Left atrial size in patients with cryptogenic stroke as a predictor of occurrence of atrial fibrillation

    Directory of Open Access Journals (Sweden)

    Antonio Cruz Culebras

    2017-04-01

    Full Text Available Objective: To determine whether the left atrial size can predict the development of atrial fibrillation (AF in patients with embolic stroke of undetermined source (ESUS. Methods: Patients with ischemic stroke were included prospectively (January 2015-July 2015 when ESUS was suspected. Clinical and cardiac imaging data were recorded. Patients with cardiac failure were excluded. Results: a total of 55 patients were included. Medium age was 71 years. The proportion of patients who developed AF during the follow-up (1 year was 23, 63%. 10 % of patients did not have any vascular risk factor. Basal ECG was normal in 98% of cases. The left atrial size volume was 36, 08 ml in patients who developed AF and 27, 14 ml in patients who did not. Conclusions: In patients with ESUS, left atrial size dimensions do not predict the occurrence of AF.

  1. Left atrial isolation associated with mitral valve operations.

    Science.gov (United States)

    Graffigna, A; Pagani, F; Minzioni, G; Salerno, J; Viganò, M

    1992-12-01

    Surgical isolation of the left atrium was performed for the treatment of chronic atrial fibrillation secondary to valvular disease in 100 patients who underwent mitral valve operations. From May 1989 to September 1991, 62 patients underwent mitral valve operations (group I); 19, mitral valve operations and DeVega tricuspid annuloplasty (group II); 15, mitral and aortic operations (group III); and 4, mitral and aortic operations and DeVega tricuspid annuloplasty (group IV). Left atrial isolation was performed, prolonging the usual left paraseptal atriotomy toward the left fibrous trigone anteriorly and the posteromedial commissure posteriorly. The incision was conducted a few millimeters apart from the mitral valve annulus, and cryolesions were placed at the edges to ensure complete electrophysiological isolation of the left atrium. Operative mortality accounted for 3 patients (3%). In 79 patients (81.4%) sinus rhythm recovered and persisted until discharge from the hospital. No differences were found between the groups (group I, 80.7%; group II, 68.5%; group III, 86.7%; group IV, 75%; p = not significant). Three late deaths (3.1%) were registered. Long-term results show persistence of sinus rhythm in 71% of group I, 61.2% of group II, 85.8% of group III, and 100% of group IV. The unique risk factor for late recurrence of atrial fibrillation was found to be preoperative atrial fibrillation longer than 6 months. Due to the satisfactory success rate in recovering sinus rhythm, we suggest performing left atrial isolation in patients with chronic atrial fibrillation undergoing valvular operations.

  2. Left Atrial Linear Ablation of Paroxysmal Atrial Fibrillation Guided by Three-dimensional Electroanatomical System

    DEFF Research Database (Denmark)

    Zhang, Dai-Fu; Li, Ying; Qi, Wei-Gang

    2005-01-01

    Objective To investigate the safety and efficacy of Left atrial linear ablation of paroxysmal atrial fibrillation guided by three-dimensional electroanatomical system. Methods 29 patients with paroxysmal atrial fibrillation in this study. A nonfluoroscopic mapping system was used to generate a 3D...... electroanatomic LA mapping, and all pulmonary vein ostia were marked under the help of pulmonary veins angiography on the 3D map. Radiofrequency (RF) energy was delivered to create continuous linear lesions encircling the pulmonary veins, it was delivered with a target temperature of 43¿, a maximal power limit...

  3. Left atrial appendage occlusion for stroke prevention in atrial fibrillation in Europe

    DEFF Research Database (Denmark)

    Lip, Gregory Y.H.; Dagres, Nikolaos; Proclemer, Alessandro

    2013-01-01

    The purpose of this EP wire survey was to assess clinical practice in relation to the use of left atrial appendage occlusion (LAAO) devices for stroke prevention in atrial fibrillation (AF) among members of the European Heart Rhythm Association research network. The average number of performed LA...... are most often performed by interventional cardiologists. Experience varied widely, and this was reflected in the wide range of thromboembolic and procedural (tamponade, bleeding) complications reported by the respondents to this EP wire survey....

  4. Impact of Atrial Fibrillation Ablation on Left Ventricular Filling Pressure and Left Atrial Remodeling

    Directory of Open Access Journals (Sweden)

    Simone Nascimento dos Santos

    2014-12-01

    Full Text Available Background: Left ventricular (LV diastolic dysfunction is associated with new-onset atrial fibrillation (AF, and the estimation of elevated LV filling pressures by E/e' ratio is related to worse outcomes in patients with AF. However, it is unknown if restoring sinus rhythm reverses this process. Objective: To evaluate the impact of AF ablation on estimated LV filling pressure. Methods: A total of 141 patients underwent radiofrequency (RF ablation to treat drug-refractory AF. Transthoracic echocardiography was performed 30 days before and 12 months after ablation. LV functional parameters, left atrial volume index (LAVind, and transmitral pulsed and mitral annulus tissue Doppler (e' and E/e' were assessed. Paroxysmal AF was present in 18 patients, persistent AF was present in 102 patients, and long-standing persistent AF in 21 patients. Follow-up included electrocardiographic examination and 24-h Holter monitoring at 3, 6, and 12 months after ablation. Results: One hundred seventeen patients (82.9% were free of AF during the follow-up (average, 18 ± 5 months. LAVind reduced in the successful group (30.2 mL/m2 ± 10.6 mL/m2 to 22.6 mL/m2 ± 1.1 mL/m2, p < 0.001 compared to the non-successful group (37.7 mL/m2 ± 14.3 mL/m2 to 37.5 mL/m2 ± 14.5 mL/m2, p = ns. Improvement of LV filling pressure assessed by a reduction in the E/e' ratio was observed only after successful ablation (11.5 ± 4.5 vs. 7.1 ± 3.7, p < 0.001 but not in patients with recurrent AF (12.7 ± 4.4 vs. 12 ± 3.3, p = ns. The success rate was lower in the long-standing persistent AF patient group (57% vs. 87%, p = 0.001. Conclusion: Successful AF ablation is associated with LA reverse remodeling and an improvement in LV filling pressure.

  5. Impact of Atrial Fibrillation Ablation on Left Ventricular Filling Pressure and Left Atrial Remodeling

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Simone Nascimento dos, E-mail: simonens@cardiol.br [Instituto Brasília de Arritmia- Universidade de Brasília, DF (Brazil); Faculdade de Medicina (UnB), Brasília, DF (Brazil); Henz, Benhur Davi; Zanatta, André Rodrigues; Barreto, José Roberto; Loureiro, Kelly Bianca; Novakoski, Clarissa; Santos, Marcus Vinícius Nascimento dos; Giuseppin, Fabio F.; Oliveira, Edna Maria; Leite, Luiz Roberto [Instituto Brasília de Arritmia- Universidade de Brasília, DF (Brazil)

    2014-12-15

    Left ventricular (LV) diastolic dysfunction is associated with new-onset atrial fibrillation (AF), and the estimation of elevated LV filling pressures by E/e' ratio is related to worse outcomes in patients with AF. However, it is unknown if restoring sinus rhythm reverses this process. To evaluate the impact of AF ablation on estimated LV filling pressure. A total of 141 patients underwent radiofrequency (RF) ablation to treat drug-refractory AF. Transthoracic echocardiography was performed 30 days before and 12 months after ablation. LV functional parameters, left atrial volume index (LAVind), and transmitral pulsed and mitral annulus tissue Doppler (e' and E/e') were assessed. Paroxysmal AF was present in 18 patients, persistent AF was present in 102 patients, and long-standing persistent AF in 21 patients. Follow-up included electrocardiographic examination and 24-h Holter monitoring at 3, 6, and 12 months after ablation. One hundred seventeen patients (82.9%) were free of AF during the follow-up (average, 18 ± 5 months). LAVind reduced in the successful group (30.2 mL/m{sup 2} ± 10.6 mL/m{sup 2} to 22.6 mL/m{sup 2} ± 1.1 mL/m{sup 2}, p < 0.001) compared to the non-successful group (37.7 mL/m{sup 2} ± 14.3 mL/m{sup 2} to 37.5 mL/m{sup 2} ± 14.5 mL/m{sup 2}, p = ns). Improvement of LV filling pressure assessed by a reduction in the E/e' ratio was observed only after successful ablation (11.5 ± 4.5 vs. 7.1 ± 3.7, p < 0.001) but not in patients with recurrent AF (12.7 ± 4.4 vs. 12 ± 3.3, p = ns). The success rate was lower in the long-standing persistent AF patient group (57% vs. 87%, p = 0.001). Successful AF ablation is associated with LA reverse remodeling and an improvement in LV filling pressure.

  6. Impact of Atrial Fibrillation Ablation on Left Ventricular Filling Pressure and Left Atrial Remodeling

    International Nuclear Information System (INIS)

    Santos, Simone Nascimento dos; Henz, Benhur Davi; Zanatta, André Rodrigues; Barreto, José Roberto; Loureiro, Kelly Bianca; Novakoski, Clarissa; Santos, Marcus Vinícius Nascimento dos; Giuseppin, Fabio F.; Oliveira, Edna Maria; Leite, Luiz Roberto

    2014-01-01

    Left ventricular (LV) diastolic dysfunction is associated with new-onset atrial fibrillation (AF), and the estimation of elevated LV filling pressures by E/e' ratio is related to worse outcomes in patients with AF. However, it is unknown if restoring sinus rhythm reverses this process. To evaluate the impact of AF ablation on estimated LV filling pressure. A total of 141 patients underwent radiofrequency (RF) ablation to treat drug-refractory AF. Transthoracic echocardiography was performed 30 days before and 12 months after ablation. LV functional parameters, left atrial volume index (LAVind), and transmitral pulsed and mitral annulus tissue Doppler (e' and E/e') were assessed. Paroxysmal AF was present in 18 patients, persistent AF was present in 102 patients, and long-standing persistent AF in 21 patients. Follow-up included electrocardiographic examination and 24-h Holter monitoring at 3, 6, and 12 months after ablation. One hundred seventeen patients (82.9%) were free of AF during the follow-up (average, 18 ± 5 months). LAVind reduced in the successful group (30.2 mL/m 2 ± 10.6 mL/m 2 to 22.6 mL/m 2 ± 1.1 mL/m 2 , p < 0.001) compared to the non-successful group (37.7 mL/m 2 ± 14.3 mL/m 2 to 37.5 mL/m 2 ± 14.5 mL/m 2 , p = ns). Improvement of LV filling pressure assessed by a reduction in the E/e' ratio was observed only after successful ablation (11.5 ± 4.5 vs. 7.1 ± 3.7, p < 0.001) but not in patients with recurrent AF (12.7 ± 4.4 vs. 12 ± 3.3, p = ns). The success rate was lower in the long-standing persistent AF patient group (57% vs. 87%, p = 0.001). Successful AF ablation is associated with LA reverse remodeling and an improvement in LV filling pressure

  7. Left atrial thrombus following bilobectomy: a case report

    Directory of Open Access Journals (Sweden)

    Kaya Ugur

    2010-02-01

    Full Text Available Abstract Introduction Left atrial free floating ball thrombus is a relatively rare event, especially without mitral valve disease. Case presentation A 61-year-old Turkish man was admitted to our hospital with a thrombus mass in his left atrium. Five months earlier, he had undergone right bilobectomy and superior bronchoplasty due to squamous cell carcinoma in the lung. The patient had no evidence of cardiac disease except atrial fibrillation and there were no defined embolizations. The thrombus mass was surgically removed. The patient was discharged from hospital on the sixth postoperative day. Conclusion Surgery with cardiopulmonary bypass is a safe method for treatment. The patient should be medicated with warfarin, especially in the presence of atrial fibrillation.

  8. The left atrial catheter: its uses and complications.

    Science.gov (United States)

    Leitman, B S; Naidich, D P; McGuinness, G; McCauley, D I

    1992-11-01

    The authors describe the radiographic appearance of the left atrial catheter, a widely used postsurgical intracardiac device. Recognition of the characteristic appearance of this catheter should be of value in detection of potential complications, including line fracture with resultant retention and/or embolization, infection, prosthetic valve dysfunction, and even cardiac tamponade.

  9. Speckle tracking analysis: a new tool for left atrial function analysis in systemic hypertension: an overview.

    Science.gov (United States)

    Cameli, Matteo; Ciccone, Marco M; Maiello, Maria; Modesti, Pietro A; Muiesan, Maria L; Scicchitano, Pietro; Novo, Salvatore; Palmiero, Pasquale; Saba, Pier S; Pedrinelli, Roberto

    2016-05-01

    Speckle tracking echocardiography (STE) is an imaging technique applied to the analysis of left atrial function. STE provides a non-Doppler, angle-independent and objective quantification of left atrial myocardial deformation. Data regarding feasibility, accuracy and clinical applications of left atrial strain are rapidly gathering. This review describes the fundamental concepts of left atrial STE, illustrates its pathophysiological background and discusses its emerging role in systemic arterial hypertension.

  10. [Left atrial electric isolation in the treatment of atrial fibrillation secondary to rheumatic valvular disease].

    Science.gov (United States)

    Graffigna, A; Pagani, F; Minzioni, G; Salerno, J; Viganò, M

    1992-08-01

    Surgical isolation of the left atrium was performed for the treatment of chronic atrial fibrillation secondary to valvular disease in 100 patients who underwent valve surgery. From May 1989 to September 1991, 62 patients underwent mitral valve surgery (Group I), 19 underwent mitral valve surgery and DeVega tricuspid annuloplasty (Group II), 15 underwent mitral and aortic surgery (Group III), and 4 patients underwent mitral and aortic surgery and DeVega tricuspid annuloplasty (Group IV). Left atrial isolation was performed prolonging the usual left paraseptal atriotomy towards the left fibrous trigone anteriorly, and the postero-medial commissure posteriorly. The incision was conducted a few millimeters apart from the mitral valve annulus, and cryolesion were placed at the edges to ensure complete electrophysiological isolation of the left atrium. Operative mortality accounted for 3 cases (3%). In 79 patients (81.4%) sinus rhythm recovered and persisted until discharge from the hospital. No differences were found between the groups (Group I: 80.7%; Group II: 68.5%; Group III 86.7%, Group IV 75% - p = N.S.). Three cases of late mortality (3.1%) were registered. long-term results showed persistence of SR in 71% of Group I, 61.2% of Group II, 85.8% of Group III, and 100% of Group IV. The unique risk factor for late recurrency of atrial fibrillation was found to be a duration of preoperative AF longer than 6 months. Due to the high success rate in recovering the sinus rhythm, we suggest left atrial isolation in patients with chronic atrial fibrillation undergoing valvular surgery.

  11. Left Atrial Sphericity Index Predicts Early Recurrence of Atrial Fibrillation After Direct-Current Cardioversion

    DEFF Research Database (Denmark)

    Osmanagic, Armin; Möller, Sören; Osmanagic, Azra

    2016-01-01

    BACKGROUND: Attempts to achieve rhythm control using direct-current cardioversion (DCC) are common in those with persistent atrial fibrillation (AF). Although often successful, AF recurs within 1 month in as many as 57% of patients. The aim of this study was to assess whether a baseline left atri...

  12. LEFT ATRIAL FUNCTION: MODERN ASSESSMENT METHODS AND CLINICAL SIGNIFICANCE

    Directory of Open Access Journals (Sweden)

    E. N. Pavlyukova

    2017-01-01

    Full Text Available Assessment of the left atrial (LA function is important aspect of comprehensive cardiovascular system estimation. Many cardiac diseases make an impact to LA work either by direct affect on myocardium or hemodynamic condition changing. It is considered, LA and left ventricle diastolic pressure is interrelated, thus without mitral valve disease LA expanding is a sign of LV filling pressure augmentation. Examination of LA size and function by analysis of atrial reservoir, conduit, and booster pump can predict cardiovascular outcomes in patients with cardiomyopathy, ischemic heart disease and valvular heart disease. The last two decades gave new technologies to accurate and comprehensive LA mechanics estimation, in the first place related to tissue Doppler imaging. Atrial strain and strain rate obtained using two-dimensional speckle-tracking echocardiography have proved to be feasible and reproducible techniques to evaluate LA mechanics.In physiological settings, LA is a highly expandable chamber with relatively low pressures. However in the presence of acute and chronic injury, LA wall stretches. LA stretching is a hallmark of structure changing with myocardial fibrosis and has influence on LA strain and strain rate. LA strain estimation could be useful in the prediction of sinus rhythm restoration and maintenance after cardioversion and catheter ablation. Low values of global longitudinal LA strain indicate irreversible LA remodeling and are related to the atrial fibrillation progression from paroxysmal to permanent forms. The most interesting in these circumstances is the potential contribution of echocardiography to thromboembolic risk stratification in atrial fibrillation and invasive procedures such as atrial ablation. Therefore, at present, the main task is to understand the ways of clinical application of data  obtained during the LA study.

  13. Case of right atrial myxoma with right to left shunt

    Energy Technology Data Exchange (ETDEWEB)

    Nakai, Kenji; Suzuki, Tomoyuki; Ohzeki, Tetsuro (Iwate Medical Coll., Morioka (Japan). School of Medicine)

    1982-12-01

    A case of 49-year-old woman with right atrial myxoma resulting to right to left shunt, diagnosed by cardiac pool isotope image, was reported. She was admitted to our clinic because of progressive shortness of breath. At admission lip cyanosis was noted. Laboratory data included polycythemia, low O/sub 2/ saturation (89%) and high erythrocyte sedimentation rate (65 mm/1 h). Chest x-p showed slight right atrial enlargement, but no pulmonary congestion. The electrocardiogram showed sinus regular rhythm with biphasic p wave in leads II, III, aVf. Although 1st heart sound at the apex was splited, no heart murmur was heard. In usual echocardiographic approach, no abnormal echogram was obtained in the right ventricular region. Lung perfusion scintiscan with Tc-99 m-MAA showed visualization of thyroid gland and kidney, which suggested intracardiac right-to-left shunt. Cardiac pool image with Tc-99m-HSA revealed large photo-deficient area in the right atrium and early visualization of aortic arch. Computor tomography showed large round low density region 8 x 7 cm in size. Based on their findings, this patient was diagnosed as right atrial tumor. At operation a large tumor (diameter 8 x 7 x 7 cm, weight 160g) filled the lower part of the right atrium and was adherent to the anterolateral wall in the right atrium. As a cause of R-L shunt, streched foramen ovale (5 x 10 mm) was found. Tumor histology was typical of atrial myxoma. Post-operative gated cardiac isotope image showed no evidence of residual atrial tumor. Cardiac blood pool isotope imaging was a method for the noninvasive detection and assessment of right atrial myxoma.

  14. Management of left atrial myxomas at civil hospital, Karachi

    International Nuclear Information System (INIS)

    Iqbal, M.I.; Khan, A.B.; Aftab, S.; Mahmood, S.A.

    2008-01-01

    To study the outcome of the management of left atrial myxoma. The diagnosis was made according to clinical presentation and echocardiographic examinations. Tumour excised under cardiopulmonary bypass using aortic and bicaval cannulation and moderate hypothermia. Variables noted were surgical approach, pathological findings and complications after surgery. Of the 12 cases, six were male and six female, with a mean age of 33.67+-6.05 years. Fatigue and fever were the most common general symptoms, and dyspnoea the most common cardiologic symptom. The pedunculated atrial tumours were excised by trans-septal approach; tumour size ranged between 1.5x1x0.7 cms to 9x8x6 cms and weight 3-140 gms. Histopathology confirmed the tumours as atrial myxomas. One patient died of cerebrovascular accident on the 3rd postoperative day. So far, there has been no recurrence of the tumours. Surgical treatment with wide excision of left atrial myxomas by trans-septal approach is a suitable approach with negligible chances of recurrence. (author)

  15. Plain chest PA evaluation of left atrial thrombosis in mitral valvular disease

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Yeon Myung; Park, Jae Hyung; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1984-09-15

    Conventional posteroanterior chest radiographs of 73 patients with mitral valve disease who had had surgery were analyzed, and particular attention was directed to the absence of the convexity of the left lower mid cardiac border (left atrial segment) and to the relation with duration of illness, atrial fibrillation, pulmonary capillary wedge pressure (PCWP) as well as surgical findings. The results obtained are as follows: 1. The flatness or concavity of this segment, despite other evidence of left atrial enlargement, was observed in eleven (64.7%) of 17 patients who had left atrial thrombosis and in six (10.7%) of 56 patients who did not have thrombosis (false positive diagnosis). Six (35.5%) of the 17 patients who had left atrial thrombosis did not this findings on radiographs (false positive diagnosis). Six (35.3%) of the 17 patients who had left atrial thrombosis did not show this finding on radiographs (false positive diagnosis). Therefore, the accuracy in the diagnosis of thrombosis of left atrium wa 64.7% (eleven of seventeen) for patients who had thrombosis of left atrium. 2. The atrial fibrillation was observed in sixteen (94.1%)of 17 patients who had left atrial thrombosis. So, correlation between the presence of left atrial thrombosis and atrial fibrillation wa evident. But there was no correlation between the duration of illness of the PCWP of patients and the presence of left atrial thrombosis.

  16. Plain chest PA evaluation of left atrial thrombosis in mitral valvular disease

    International Nuclear Information System (INIS)

    Choo, Yeon Myung; Park, Jae Hyung; Han, Man Chung

    1984-01-01

    Conventional posteroanterior chest radiographs of 73 patients with mitral valve disease who had had surgery were analyzed, and particular attention was directed to the absence of the convexity of the left lower mid cardiac border (left atrial segment) and to the relation with duration of illness, atrial fibrillation, pulmonary capillary wedge pressure (PCWP) as well as surgical findings. The results obtained are as follows: 1. The flatness or concavity of this segment, despite other evidence of left atrial enlargement, was observed in eleven (64.7%) of 17 patients who had left atrial thrombosis and in six (10.7%) of 56 patients who did not have thrombosis (false positive diagnosis). Six (35.5%) of the 17 patients who had left atrial thrombosis did not this findings on radiographs (false positive diagnosis). Six (35.3%) of the 17 patients who had left atrial thrombosis did not show this finding on radiographs (false positive diagnosis). Therefore, the accuracy in the diagnosis of thrombosis of left atrium wa 64.7% (eleven of seventeen) for patients who had thrombosis of left atrium. 2. The atrial fibrillation was observed in sixteen (94.1%)of 17 patients who had left atrial thrombosis. So, correlation between the presence of left atrial thrombosis and atrial fibrillation wa evident. But there was no correlation between the duration of illness of the PCWP of patients and the presence of left atrial thrombosis.

  17. Association Between Left Atrial Compression And Atrial Fibrillation: A Case Presentation And A Short Review Of Literature.

    Science.gov (United States)

    Ahmed, Niloy; Carlos, Morales-Mangual; Moshe, Gunsburg; Yitzhak, Rosen

    2016-01-01

    This case report describes a patient who developed palpitations and chest pain and was found to be in atrial fibrillation, which was likely due to the presence of an extra-cardiac mass. This was compressing the left atrium. The mass was related to small cell carcinoma, which decreased significantly in size after chemotherapy. Resolution of the atrial fibrillation correlated temporally with reduction in the size of the mass and alleviation of the left atrial compression.

  18. Left atrial low-voltage areas predict atrial fibrillation recurrence after catheter ablation in patients with paroxysmal atrial fibrillation.

    Science.gov (United States)

    Masuda, Masaharu; Fujita, Masashi; Iida, Osamu; Okamoto, Shin; Ishihara, Takayuki; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Matsuda, Yasuhiro; Okuno, Shota; Ohashi, Takuya; Tsuji, Aki; Mano, Toshiaki

    2018-04-15

    Association between the presence of left atrial low-voltage areas and atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI) has been shown mainly in persistent AF patients. We sought to compare the AF recurrence rate in paroxysmal AF patients with and without left atrial low-voltage areas. This prospective observational study included 147 consecutive patients undergoing initial ablation for paroxysmal AF. Voltage mapping was performed after PVI during sinus rhythm, and low-voltage areas were defined as regions where bipolar peak-to-peak voltage was low-voltage areas after PVI were observed in 22 (15%) patients. Patients with low-voltage areas were significantly older (72±6 vs. 66±10, plow-voltage areas than without (36% vs. 6%, pLow-voltage areas were independently associated with AF recurrence even after adjustment for the other related factors (Hazard ratio, 5.89; 95% confidence interval, 2.16 to 16.0, p=0.001). The presence of left atrial low-voltage areas after PVI predicts AF recurrence in patients with paroxysmal AF as well as in patients with persistent AF. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. [Left atrial function and left atrial appendage flow velocity in hypertrophic cardiomyopathy: comparison of patients with and without paroxysmal atrial fibrillation].

    Science.gov (United States)

    Akasaka, K; Kawashima, E; Shiokoshi, T; Ishii, Y; Hasebe, N; Kikuchi, K

    1998-07-01

    The involvement of left atrial (LA) appendage flow velocity in reduced left atrial function was investigated in 24 patients with hypertrophic cardiomyopathy, who retained sinus rhythm at the examination. Patients were divided into 11 with a history of paroxysmal atrial fibrillation [PAf(+)] and 13 without such history [PAf(-)]. Transthoracic echocardiography was performed to evaluate LA fractional shortening (LA%FS) and mean velocity of circumferential LA fiber shortening (LAmVcf), as contractile functions of the left atrium at the phase of active atrial contraction. Transesophageal echocardiographic Doppler examination was performed in all patients to measure the LA appendage velocity. In all patients, significant positive correlations were observed between the LA appendage velocity and LA%FS (r = 0.50, p fibrillation were significantly lower than in those without (0.84 +/- 0.15 vs 1.28 +/- 0.37 circ/sec, 44 +/- 12 vs 65 +/- 20 cm/sec, both p fibrillation. These results indicate that there is a close relationship between LA appendage velocity and LA contractile function in patients with hypertrophic cardiomyopathy with paroxysmal atrial fibrilation, and these patients have potential risk of cerebral infarction.

  20. Left atrial function in heart failure with impaired and preserved ejection fraction.

    Science.gov (United States)

    Fang, Fang; Lee, Alex Pui-Wai; Yu, Cheuk-Man

    2014-09-01

    Left atrial structural and functional changes in heart failure are relatively ignored parts of cardiac assessment. This review illustrates the pathophysiological and functional changes in left atrium in heart failure as well as their prognostic value. Heart failure can be divided into those with systolic dysfunction and heart failure with preserved ejection fraction (HFPEF). Left atrial enlargement and dysfunction commonly occur in systolic heart failure, in particular, in idiopathic dilated cardiomyopathy. Atrial enlargement and dysfunction also carry important prognostic value in systolic heart failure, independently of known parameters such as left ventricular ejection fraction. In HFPEF, there is evidence of left atrial enlargement, impaired atrial compliance, and reduction of atrial pump function. This occurs not only at rest but also during exercise, indicating significant impairment of atrial contractile reserve. Furthermore, atrial dyssynchrony is common in HFPEF. These factors further contribute to the development of new onset or progression of atrial arrhythmias, in particular, atrial fibrillation. Left atrial function is an integral part of cardiac function and its structural and functional changes in heart failure are common. As changes of left atrial structure and function have different clinical implications in systolic heart failure and HFPEF, routine assessment is warranted.

  1. Relationship of left atrial enlargement to persistence or development of ECG left ventricular hypertrophy in hypertensive patients: implications for the development of new atrial fibrillation

    DEFF Research Database (Denmark)

    Okin, Peter M; Gerdts, Eva; Wachtell, Kristian

    2010-01-01

    Persistence and development of ECG left ventricular hypertrophy (LVH) by Cornell product criteria are associated with an increased risk of atrial fibrillation compared with regression or continued absence of LVH. We postulated that this association might be in part mediated via greater left atrial...... enlargement (LAE) in patients with new and persistent ECG LVH....

  2. ABO blood groups: A risk factor for left atrial and left atrial appendage thrombogenic milieu in patients with non-valvular atrial fibrillation.

    Science.gov (United States)

    Fu, Yuan; Li, Kuibao; Yang, Xinchun

    2017-08-01

    Previous studies have identified ABO blood groups as predictors of thromboembolic diseases. In patients with atrial fibrillation (AF), however, potential association between ABO blood groups and the risk of left atrial (LA) and/or left atrial appendage (LAA) thrombogenic milieu (TM) has not been established. This is a retrospective case-control study that included 125 consecutive patients with non-valvular atrial fibrillation (NVAF) plus TM, as evidenced by transesophageal echocardiography (TEE) during a period from1 January 2010 to 31 December 2016. The controls were selected randomly from 1072 NVAF without TM at a 1:2 ratio. Potential association between ABO blood groups and TM was analyzed using multivariate logistic regression analysis. The risk of TM was higher in patients with blood group A (33.6% vs. 20.2% in non-A blood groups, P=0.005). After adjusting for age, sex, oral anticoagulant use, AF type and duration, and relevant functional measures (e.g., NT-pro BNP level, left atrium diameter, and left ventricular ejection fraction), blood group A remained associated with an increased risk of TM (OR=2.99, 95% CI 1.4-6.388, P=0.005). Blood group A is an independent risk factor for TM in NVAF patients. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Combined percutaneous balloon mitral valvuloplasty and left atrial appendage occlusion device implantation for rheumatic mitral stenosis and atrial fibrillation

    International Nuclear Information System (INIS)

    Murdoch, Dale; McAulay, Laura; Walters, Darren L.

    2014-01-01

    Rheumatic heart disease is a common cause of cardiovascular morbidity and mortality worldwide, mostly in developing countries. Mitral stenosis and atrial fibrillation often coexist, related to both structural and inflammatory changes of the mitral valve and left atrium. Both predispose to left atrial thrombus formation, commonly involving the left atrial appendage. Thromboembolism can occur, with devastating consequences. We report the case of a 62 year old woman with rheumatic heart disease resulting in mitral stenosis and atrial fibrillation. Previous treatment with warfarin resulted in life-threatening gastrointestinal bleeding and she refused further anticoagulant therapy. A combined procedure was performed, including percutaneous balloon mitral valvuloplasty and left atrial appendage occlusion device implantation with the Atritech® Watchman® device. No thromboembolic or bleeding complications were encountered at one year follow-up. Long-term follow-up in a cohort of patients will be required to evaluate the safety and efficacy of this strategy

  4. Combined percutaneous balloon mitral valvuloplasty and left atrial appendage occlusion device implantation for rheumatic mitral stenosis and atrial fibrillation

    Energy Technology Data Exchange (ETDEWEB)

    Murdoch, Dale, E-mail: dale_murdoch@health.qld.gov.au [The Prince Charles Hospital, Brisbane (Australia); The University of Queensland, Brisbane (Australia); McAulay, Laura [The Prince Charles Hospital, Brisbane (Australia); Walters, Darren L. [The Prince Charles Hospital, Brisbane (Australia); The University of Queensland, Brisbane (Australia)

    2014-11-15

    Rheumatic heart disease is a common cause of cardiovascular morbidity and mortality worldwide, mostly in developing countries. Mitral stenosis and atrial fibrillation often coexist, related to both structural and inflammatory changes of the mitral valve and left atrium. Both predispose to left atrial thrombus formation, commonly involving the left atrial appendage. Thromboembolism can occur, with devastating consequences. We report the case of a 62 year old woman with rheumatic heart disease resulting in mitral stenosis and atrial fibrillation. Previous treatment with warfarin resulted in life-threatening gastrointestinal bleeding and she refused further anticoagulant therapy. A combined procedure was performed, including percutaneous balloon mitral valvuloplasty and left atrial appendage occlusion device implantation with the Atritech® Watchman® device. No thromboembolic or bleeding complications were encountered at one year follow-up. Long-term follow-up in a cohort of patients will be required to evaluate the safety and efficacy of this strategy.

  5. Assessment of left atrial volume and function in patients with permanent atrial fibrillation

    DEFF Research Database (Denmark)

    Agner, Bue F Ross; Kühl, Jørgen Tobias; Linde, Jesper James

    2014-01-01

    Atrial fibrillation (AF) is a common cardiac arrhythmia that is associated with substantial morbidity and mortality. AF is associated with enlargement of the left atrium (LA), and the LA volume has important prognostic implications for the disease. The objective of the study was to determine how...... measurements of LA volume and function obtained by transthoracic echocardiography (TTE), cardiac magnetic resonance (CMR), and 320-slice multi-detector computed tomography (MDCT) correlate in patients with permanent AF....

  6. Early changes in left atrial volume after acute myocardial infarction

    DEFF Research Database (Denmark)

    Bakkestrom, R.; Andersen, Mads J; Ersboll, M.

    2016-01-01

    . The objective was to assess changes in LA volume early after MI in patients with diastolic dysfunction and the relation to invasive hemodynamics and natriuretic peptides. Methods: 62 patients with left ventricle ejection fraction (LVEF) >= 45%, diastolic E/e' > 8 and LA volume index >34 ml/m(2) within 48 h......Background: Dilatation of left atrium (LA) reflects chronic LA pressure or volume overload that possesses considerable prognostic information. Little is known regarding the interaction between LA remodeling after acute myocardial infarction (MI) and left atrial pressure at rest and during exercise...... of MI were enrolled. After 1 and 4 months blood sampling, echocardiography and right heart catheterization were performed during exercise test. Results: LA remodeling was considered in patients with a change from mild (35-41 ml/m(2)), to severe (>48ml/m(2)) dilatation after 4 months (Found in 22...

  7. Hemostasis of Left Atrial Appendage Bleed With Lariat Device

    Directory of Open Access Journals (Sweden)

    Amena Hussain, MD

    2014-09-01

    Full Text Available New devices designed for minimally invasive closure of the left atrial appendage (LAA may be a viable alternative for patients in whom anticoagulation is considered high risk. The Lariat (Sentreheart, Redwood City, CA, which is currently FDA-approved for percutaneous closure of tissue, requires both trans-septal puncture and epicardial access. However it requires no anticoagulation after the procedure. Here we describe a case of effusion and tamponade during a Lariat procedure with successful completion of the case and resolution of the effusion.

  8. Atrial conduction times and left atrial mechanical functions and their relation with diastolic function in prediabetic patients.

    Science.gov (United States)

    Gudul, Naile Eris; Karabag, Turgut; Sayin, Muhammet Rasit; Bayraktaroglu, Taner; Aydin, Mustafa

    2017-03-01

    The aim of this study was to investigate atrial conduction times and left atrial mechanical functions, the noninvasive predictors of atrial fibrillation, in prediabetic patients with impaired fasting glucose (IFG) and impaired glucose tolerance (IGT). Study included 59 patients (23 males, 36 females; mean age 52.5 ± 10.6 years) diagnosed with IFG or IGT by the American Diabetes Association criteria, and 43 healthy adults (22 males, 21 females; mean age 48.5 ± 12.1 years). Conventional and tissue Doppler echocardiography were performed. The electromechanical delay parameters were measured from the onset of the P wave on the surface electrocardiogram to the onset of the atrial systolic wave on tissue Doppler imaging from septum, lateral, and right ventricular annuli. The left atrial volumes were calculated by the disk method. Left atrial mechanical functions were calculated. The mitral E/A and E'/A' ratios measured from the lateral and septal annuli were significantly lower in the prediabetics compared to the controls. The interatrial and left atrial electromechanical delay were significantly longer in prediabetic group compared to the controls. Left atrial active emptying volume (LAAEV) and fraction (LAAEF) were significantly higher in the prediabetics than the controls. LAAEV and LAAEF were significantly correlated with E/A, lateral and septal E'/A'. In the prediabetic patients, the atrial conduction times and P wave dispersion on surface electrocardiographic were longer before the development of overt diabetes. In addition, the left atrial mechanical functions were impaired secondary to a deterioration in the diastolic functions in the prediabetic patients.

  9. Pulmonary artery-to-left atrial fistula discovered after the closure of atrial septal defect: A rare clinical scenario

    Directory of Open Access Journals (Sweden)

    Akshay Chauhan

    2018-01-01

    Full Text Available A case of the right pulmonary artery-to- left atrial fistula with atrial septal defect (ASD is presented. The fistula was detected after the patient developed desaturation following surgical closure of the ASD. It was managed with a transcatheter (trans-RPA route closure of the fistula using a 12-mm Amplatzer ventricular septal defect closure device.

  10. Does Left Atrial Volume and Pulmonary Venous Anatomy Predict the Outcome of Catheter Ablation of Atrial Fibrillation ?

    NARCIS (Netherlands)

    Hof, Irene; Chilukuri, Karuna; Arbab-Zadeh, Armin; Scherr, Daniel; Dalal, Darshan; Nazarian, Saman; Henrikson, Charles; Spragg, David; Berger, Ronald; Marine, Joseph; Calkins, Hugh

    Introduction: Preprocedural factors may be helpful in selecting patients with atrial fibrillation (AF) for treatment with catheter ablation and in making an assumption regarding their prognosis. The aims of this study were to investigate whether left atrial (LA) volume and pulmonary venous (PV)

  11. Left atrial appendage thrombosis during therapy with rivaroxaban in elective cardioversion for permanent atrial fibrillation

    Directory of Open Access Journals (Sweden)

    Walter Serra

    2015-09-01

    Full Text Available Electric external cardioversion (EEC for permanent atrial fibrillation (AF carries a risk of thromboembolic events (TE. The use of transesophageal echocardiography (TEE to guide the management of atrial fibrillation may be considered a clinically effective alternative strategy to conventional therapy for patients in whom elective cardioversion is planned. Therapeutic anticoagulation with novel oral anticoagulants (NOAC is recommended for 3 to 4 weeks before and an anticoagulation life-long therapy is recommended after EEC to reduce TE, in patients with high CHA2DS2-VASc score; however, only few data are currently available about safety of shortterm anticoagulation with NOAC in the setting of EEC. Patients with increased risk of thromboembolism have not been adequately studied and the monitoring of anticoagulant effects can also have important benefits in case of drug interactions. We report a case of a 68-year old man with AF from September 2014. Moderate depression of global left ventricular systolic function was detected by echocardiographic exam. On the basis of a high thromboembolic risk, an anticoagulant therapy with rivaroxaban, at the dose of 20 mg/day, was started. TEE showed a thrombus in the left atrial appendage. This case demonstrates the utility of performing TEE prior than EEC in patients with hypokinetic cardiomyopathy other than AF in therapy with NOAC. We underline the presence of significant pharmacodynamic interference of rivaroxaban with other drugs such as oxcarbazepine.

  12. Left Atrial Appendage Closure in Atrial Fibrillation: A World without Anticoagulation?

    Directory of Open Access Journals (Sweden)

    Tahmeed Contractor

    2011-01-01

    Full Text Available Atrial Fibrillation (AF is a common arrhythmia with an incidence that is as high as 10% in the elderly population. Given the large proportion of strokes caused by AF as well as the associated morbidity and mortality, reducing stroke burden is the most important part of AF management. While warfarin significantly reduces the risk of AF-related stroke, perceived bleeding risks and compliance limit its widespread use in the high-risk AF population. The left atrial appendage is believed to be the “culprit” for thrombogenesis in nonvalvular AF and is a new therapeutic target for stroke prevention. The purpose of this review is to explore the evolving field of percutaneous LAA occlusion. After briefly highlighting the risk of stroke with AF, problems with warfarin, and the role of the LAA in clot formation, this article discusses the feasibility and efficacy of various devices which have been developed for percutaneous LAA occlusion.

  13. Left atrial spindle cell sarcoma – Case report

    Directory of Open Access Journals (Sweden)

    Nihar Mehta

    2012-07-01

    Full Text Available Primary spindle cell sarcoma of the left atrium is an extremely rare tumour. Surgical excision is the mainstay of treatment since it responds poorly to chemotherapy or radiotherapy. In spite of all the treatment, the prognosis remains poor due to inadvertent delay in diagnosis, few therapeutic options and propensity to metastasize. We present a 47-year-old male who underwent a surgical excision of a left atrial mass in February 2010. It was proved to be a high-grade spindle cell sarcoma on histopathology. He presented again in October 2010 with recurrence of the tumour for which he was re-operated. However, the tumour recurred again within one month, to which the patient succumbed.

  14. Left Atrial Systolic Force in Asymptomatic Aortic Stenosis

    DEFF Research Database (Denmark)

    Cioffi, Giovanni; Cramariuc, Dana; Dalsgaard, Morten

    2011-01-01

    LASF in the total study population was 21 ± 14 kdynes/cm(2) . The determinants of LASF were higher age, heart rate, body mass index, systolic blood pressure, left ventricular (LV) mass, mitral peak early velocity, maximal LA volume, and longer mitral deceleration time (multiple R(2) = 0.37, P ...Background: There is a limited knowledge about left atrial (LA) systolic force (LASF) and its key determinants in patients with asymptomatic mild-moderate aortic stenosis (AS). Methods: We used baseline clinic and echocardiographic data from 1,566 patients recruited in the simvastatin ezetimibe...... in aortic stenosis study evaluating the effect of placebo-controlled combined simvastatin and ezetimibe treatment in asymptomatic AS. The LASF was calculated by Manning's method. Low and high LASF were defined as 95th percentile of the distribution within the study population, respectively. Results: Mean...

  15. Spatial Relation Between Left Atrial Anatomical Contact Areas and Circular Activation in Persistent Atrial Fibrillation.

    Science.gov (United States)

    Nakahara, Shiro; Yamaguchi, Takanori; Hori, Yuichi; Anjo, Naofumi; Hayashi, Akiko; Kobayashi, Sayuki; Komatsu, Takaaki; Sakai, Yoshihiko; Fukui, Akira; Tsuchiya, Takeshi; Taguchi, Isao

    2016-05-01

    Atrial low-voltage zones (LVZs) may be related to maintenance of atrial fibrillation (AF). The influence of left atrial (LA) contact areas (CoAs) on reentrant or rotor-like sources maintaining AF has not been investigated. Forty patients with persistent AF (PsAF) were analyzed. Three representative CoA regions in the LA (ascending aorta: anterior wall; descending aorta: left inferior pulmonary vein; and vertebrae: posterior wall) were visualized by enhanced CT. Using circular catheters, the LVZs (80% of the mean AF cycle length. A pivot was defined as the core of the localized circular activation. Anterior (39/40 patients, 98%), left pulmonary vein antrum (27/40, 68%), and posterior (19/40, 48%) CoAs were identified, and 80% (68/85) of those sites were overlapped by or close (<3 mm) to LVZs. Thirty-six (90%) patients demonstrated circular activation (3.1±1.7 sites/patients) along with significantly higher organized dominant frequencies (6.3 ± 0.5 Hz, regularity-index: 0.26 [0.23-0.41]) within the LA, and the average electrogram amplitude of those pivots was 0.30 mV (0.18-0.52). Of those sites, 55% (66/120) were located at or close to CoA regions. Catheter ablation including of LVZs neighboring CoAs terminated AF in 9 (23%) patients. External anatomical structures contacting the LA may be related to unique conduction properties in diseased myocardium necessary for PsAF maintenance. © 2016 Wiley Periodicals, Inc.

  16. Left atrial appendage obliteration in atrial fibrillation patients undergoing bioprosthetic mitral valve replacement.

    Science.gov (United States)

    Min, X P; Zhu, T Y; Han, J; Li, Y; Meng, X

    2016-02-01

    Left atrial appendage (LAA) obliteration is a proven stroke-preventive measure for patients with nonvalvular atrial fibrillation (AF). However, the efficacy of LAA obliteration for patients with AF after bioprosthetic mitral valve replacement (MVR) remains unclear. This study aimed to estimate the efficacy of LAA obliteration in preventing embolism and to investigate the predictors of thromboembolism after bioprosthetic MVR. We retrospectively studied 173 AF subjects with bioprosthetic MVR; among them, 81 subjects underwent LAA obliteration using an endocardial running suture method. The main outcome measure was the occurrence of thrombosis events (TEs). The mean follow-up time was 40 ± 17 months. AF rhythm was observed in 136 patients postoperatively. The incidence rate of TEs was 13.97 % for postoperative AF subjects; a dilated left atrium (LA; > 49.5 mm) was identified as an independent risk factor of TEs (OR = 10.619, 95 % CI = 2.754-40.94, p = 0.001). For postoperative AF patients with or without LAA, the incidence rate of TEs was 15.8 % (9/57) and 12.7 % (10/79; p = 0.603), respectively. The incidence rate of TEs was 2.7 % (1/36) and 4.2 % (2/48) for the subgroup patients with a left atrial diameter of  49.5 mm (p = 0.346). Surgical LAA obliteration in patients with valvular AF undergoing bioprosthetic MVR did not reduce TEs, even when the CHA2DS2-VASc score (a score for estimating the risk of stroke in AF) was ≥ 2 points.

  17. The Prognostic Value of Left Atrial Peak Reservoir Strain in Acute Myocardial Infarction Is Dependent on Left Ventricular Longitudinal Function and Left Atrial Size

    DEFF Research Database (Denmark)

    Ersbøll, Mads; Andersen, Mads J; Valeur, Nana

    2013-01-01

    of PALS and left ventricular longitudinal strain (global longitudinal strain) in large-scale populations in regard to prognosis. METHODS AND RESULTS: We prospectively included 843 patients (mean age 62.1+/-11.8; 74% male) with acute myocardial infarction and measured global longitudinal strain, left......BACKGROUND: Peak atrial longitudinal strain (PALS) during the reservoir phase has been proposed as a measure of left atrium function in a range of cardiac conditions, with the potential for added pathophysiological insight and prognostic value. However, no studies have assessed the interrelation...

  18. Correlation of right atrial appendage velocity with left atrial appendage velocity and brain natriuretic Peptide.

    Science.gov (United States)

    Kim, Bu-Kyung; Heo, Jung-Ho; Lee, Jae-Woo; Kim, Hyun-Soo; Choi, Byung-Joo; Cha, Tae-Joon

    2012-03-01

    Left atrial appendage (LAA) anatomy and function have been well characterized both in healthy and diseased people, whereas relatively little attention has been focused on the right atrial appendage (RAA). We sought to evaluate RAA flow velocity and to compare these parameters with LAA indices and with a study of biomarkers, such as brain natriuretic peptide, among patients with sinus rhythm (SR) and atrial fibrillation (AF). In a series of 79 consecutive patients referred for transesophageal echocardiography, 43 patients (23 with AF and 20 controls) were evaluated. AF was associated with a decrease in flow velocity for both LAA and RAA [LAA velocity-SR vs. AF: 61 ± 22 vs. 29 ± 18 m/sec (p vs. AF: 46 ± 20 vs. 19 ± 8 m/sec (p brain natriuretic peptide (BNP). AF was associated with decreased RAA and LAA flow velocities. RAA velocity was found to be positively correlated with LAA velocity and negatively correlated with BNP. The plasma BNP concentration may serve as a determinant of LAA and RAA functions.

  19. Left atrial accessory appendages, diverticula, and left-sided septal pouch in multi-slice computed tomography. Association with atrial fibrillation and cerebrovascular accidents.

    Science.gov (United States)

    Hołda, Mateusz K; Koziej, Mateusz; Wszołek, Karolina; Pawlik, Wiesław; Krawczyk-Ożóg, Agata; Sorysz, Danuta; Łoboda, Piotr; Kuźma, Katarzyna; Kuniewicz, Marcin; Lelakowski, Jacek; Dudek, Dariusz; Klimek-Piotrowska, Wiesława

    2017-10-01

    The aim of this study is to provide a morphometric description of the left-sided septal pouch (LSSP), left atrial accessory appendages, and diverticula using cardiac multi-slice computed tomography (MSCT) and to compare results between patient subgroups. Two hundred and ninety four patients (42.9% females) with a mean of 69.4±13.1years of age were investigated using MSCT. The presence of the LSSP, left atrial accessory appendages, and diverticula was evaluated. Multiple logistic regression analysis was performed to check whether the presence of additional left atrial structures is associated with increased risk of atrial fibrillation and cerebrovascular accidents. At least one additional left atrial structure was present in 51.7% of patients. A single LSSP, left atrial diverticulum, and accessory appendage were present in 35.7%, 16.0%, and 4.1% of patients, respectively. After adjusting for other risk factors via multiple logistic regression, patients with LSSP are more likely to have atrial fibrillation (OR=2.00, 95% CI=1.14-3.48, p=0.01). The presence of a LSSP was found to be associated with an increased risk of transient ischemic attack using multiple logistic regression analysis after adjustment for other risk factors (OR=3.88, 95% CI=1.10-13.69, p=0.03). In conclusion LSSPs, accessory appendages, and diverticula are highly prevalent anatomic structures within the left atrium, which could be easily identified by MSCT. The presence of LSSP is associated with increased risk for atrial fibrillation and transient ischemic attack. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Effect of mitral regurgitation on cerebrovascular accidents in patients with atrial fibrillation and left atrial thrombus.

    Science.gov (United States)

    Nair, Chandra K; Aronow, Wilbert S; Shen, Xuedong; Anand, Kishlay; Holmberg, Mark J; Esterbrooks, Dennis J

    2009-11-01

    The effect of mitral regurgitation (MR) on the incidence of new cerebrovascular accidents (CVA) and mortality in patients with atrial fibrillation (AF) and left atrial thrombus (LAT) is unknown. To investigate the effect of MR in patients with AF and LAT on new CVA and mortality. Eighty nine consecutive patients, mean age 71 years, with AF and LAT documented by transesophageal echocardiography were investigated to determine the prevalence and severity of MR and the association of the severity of MR with new cerebrovascular accidents (CVA) and mortality at 34-mo follow-up. Of 89 patients, 1 + MR was present in 23 patients (26%), 2 + MR in 44 patients (50%), 3 + MR in 17 patients (19%), and 4 + MR in 3 patients (4%). Mean follow-up was 34 +/- 28 mo. The Cox proportional hazards model showed that the severity of increased MR did not significantly increase new CVA or mortality at 34-mo follow-up. The only variable predictive of mortality was left ventricular ejection fraction (LVEF), and with every unit increase in LVEF, the risk decreased by 3%. MR occurred in 87 of 89 patients (98%) with AF and LAT. There was no association between the severity of MR and the incidence of CVA or mortality.

  1. Multimodality Cardiac Imaging for the Assessment of Left Atrial Function and the Association With Atrial Arrhythmias

    DEFF Research Database (Denmark)

    Olsen, Flemming Javier; Bertelsen, Litten; de Knegt, Martina Chantal

    2016-01-01

    Several cardiac imaging modalities are able to visualize the left atrium (LA) and, therefore, allow for quantification of both structural and functional properties of this cardiac chamber. In echocardiography, only the maximal LA volume is included in the assessment of diastolic function at the c......Several cardiac imaging modalities are able to visualize the left atrium (LA) and, therefore, allow for quantification of both structural and functional properties of this cardiac chamber. In echocardiography, only the maximal LA volume is included in the assessment of diastolic function...... atrial fibrillation, which will be a point of focus in this review. Pivotal cardiac magnetic resonance imaging studies have revealed high correlation between LA fibrosis and risk of atrial fibrillation recurrence after catheter ablation, and subsequent multimodality imaging studies have uncovered...... an inverse relationship between LA reservoir function and degree of LA fibrosis. This has sparked an increased interest into the application of advanced imaging modalities, including both speckle tracking echocardiography and tissue tracking by cardiac magnetic resonance imaging. Even though increasing...

  2. Left Atrial Mechanical Function and Global Strain in Hypertrophic Cardiomyopathy.

    Directory of Open Access Journals (Sweden)

    Kyung-Jin Kim

    Full Text Available Atrial fibrillation is the most common arrhythmia and is associated with adverse outcomes in hypertrophic cardiomyopathy (HCM. Although left atrial (LA remodeling and dysfunction are known to associate with the development of atrial fibrillation in HCM, the changes of the LA in HCM patients remain unclear. This study aimed to evaluate the changes in LA size and mechanical function in HCM patients compared to control subjects and to determine the characteristics of HCM associated with LA remodeling and dysfunction.Seventy-nine HCM patients (mean age, 54 ± 11 years; 76% were men were compared to 79 age- and sex-matched controls (mean age, 54 ± 11 years; 76% were men and 20 young healthy controls (mean age, 33 ± 5 years; 45% were men. The LA diameter, volume, and mechanical function, including global strain (ε, were evaluated by 2D-speckle tracking echocardiography. The phenotype of HCM, maximal left ventricular (LV wall thickness, LV mass, and presence and extent of late gadolinium enhancement (LGE were evaluated with cardiac magnetic resonance imaging.HCM patients showed increased LA volume index, impaired reservoir function, and decreased LA ε compared to the control subjects. When we divided the HCM group according to a maximal LA volume index (LAVImax of 38.7 ml/m2 or LA ε of 21%, no significant differences in the HCM phenotype and maximal LV wall thickness were observed for patients with LAVImax >38.7 ml/m2 or LA ε ≤21%. Conversely, the LV mass index was significantly higher both in patients with maximal LA volume index >38.7 ml/m2 and with LA ε ≤21% and was independently associated with LAVImax and LA ε. Although the LGE extent was increased in patients with LA ε ≤21%, it was not independently associated with either LAVImax or LA ε.HCM patients showed progressed LA remodeling and dysfunction; the determinant of LA remodeling and dysfunction was LV mass index rather than LV myocardial fibrosis by LGE-magnetic resonance

  3. Thickening of the left atrial wall shortly after radiofrequency ablation predicts early recurrence of atrial fibrillation

    International Nuclear Information System (INIS)

    Yokokawa, Miki; Koyama, Keiko; Ino, Toshihiko; Naito, Shigeto; Oshima, Shigeru; Taniguchi, Koichi; Tada, Hiroshi

    2010-01-01

    Inflammatory responses following atrial fibrillation (AF) ablation may aggravate arrhythmogenic activity and cause an early recurrence of AF (ERAF). In 56 patients who underwent circumferential pulmonary vein ablation (CPVA) for paroxysmal AF, cardiovascular magnetic resonance imaging (CMRI) was evaluated in 5 subdivided left atrial (LA) regions before the CPVA and at 1 day and 1 month after. At a mean of 7±10 days after the CPVA, 23 patients (41%) developed 1 or more episodes of AF (ERAF group), while 33 patients (59%) remained free from AF during the first month of follow up (no-ERAF group). LA wall thickness increased 1 day after the CPVA in both groups, as demonstrated by high T2-weighted signal. The LA roof thickness and its increase, however, were greater in the ERAF group than in the no-ERAF group (P<0.05). Regions of delayed enhancement (DE) were also frequently detected in both groups, but the total number of DE regions did not differ between the 2 groups. The thickening of the LA wall associated with a high T2-weighted signal resolved within 1 month. No significant difference between the 2 groups was found in any of the CMRI parameters before or 1 month after CPVA. Thickening of the LA roof shortly after CPVA may predict an ERAF. (author)

  4. Left atrial appendage closure: a new technique for clinical practice.

    Science.gov (United States)

    John Camm, A; Colombo, Antonio; Corbucci, Giorgio; Padeletti, Luigi

    2014-03-01

    Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia. It is associated with increased risk for stroke mainly due to cardiac embolism from the left atrial appendage (LAA). Occlusion of the LAA by means of a device represents a valid alternative to oral anticoagulation, mainly in patients who cannot tolerate this therapy because of a high bleeding risk. Recent data on the endocardial device WATCHMAN show encouraging results for this patient population in terms of stroke risk reduction compared to the expected rate as well as in terms of implant success. This article reviews all relevant publications related to the main surgical and transcatheter devices used for LAA closure (LAAC). PROTECT-AF, the first prospective randomized trial conducted on this technique, showed that LAA occlusion using the WATCHMAN was noninferior to warfarin for a combined end-point in patients with nonvalvular AF. There is a lack of large-scale randomized trials on long-term stroke risk in patients submitted to LAAC. Most studies are relatively small and focus on the comparison of different surgical techniques with regard to complete/incomplete closure success. More recently, PROTECT-AF long-term results (4-year follow-up) demonstrated that LAAC was statistically superior to warfarin in terms of efficacy. This review concludes that it is now appropriate to consider these techniques for patients with AF who are at high risk for stroke for whom effective conventional or novel anticoagulant therapy is not available or who present problems in managing drug treatment. Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  5. Catheter Ablation of Ectopic Atrial Tachycardia Originating from the Left Atrial Appendage using CARTOMERGE® System

    Directory of Open Access Journals (Sweden)

    Masahiko Goya, MD

    2008-01-01

    Full Text Available A 70-year-old woman was referred because of drug resistant and daily incessant palpitation attack. She had undergone two previous unsuccessful radiofrequency catheter ablations at another hospital. The physical examination, chest X-ray, and echocardiogram were all normal. The 12-lead ECG during tachycardia showed narrow QRS, short PR tachycardia and negative polarity of the P wave in leads I and aVL (Fig. 1A. The ECG monitor showed incessant tachycardia with warming-up phenomenon. Three dimensional electroanatomical map integrated with CT imaging (CARTOMERGE®, Biosense Webster Inc. clearly revealed the radial activation pattern originating from the basalo-postero-inferior aspect of the left atrial appendage. Radiofrequency energy application at this site eliminated tachycardia permanently.

  6. Left atrial myxoma, ruptured chordae tendinae causing mitral regurgitation and coronary artery disease

    Directory of Open Access Journals (Sweden)

    Bhupesh Kumar

    2014-01-01

    Full Text Available Mitral regurgitation is uncommon with left atrial myxoma. The echocardiographic assessment of presence of mitral regurgitation and its severity are impaired by the presence of left atrial myxoma. We describe an uncommon association of left atrial myxoma with coronary artery disease and mitral regurgitation. MR was reported as mild on pre-operative transthoracic echocardiography but found to be severe due to ruptured chordae tendinae during intra-operative transesophageal echocardiography, which lead to change in the surgical plan to mitral valve replacement in addition to excision of myxoma.

  7. [Quantitative Measurements on the Blood Flow Fields of Left Atrial Appendage using Vector Flow Mapping in Patients with Nonvalvular Atrial Fibrillation].

    Science.gov (United States)

    Cai, Yu-Yan; Wei, Xin; Zhang, Xiao-Ling; Liu, Gu-Yue; Li, Xi; Tang, Hong

    2018-01-01

    To quantify the hemodynamic characteristics of patients with nonvalvular atrial fibrillation. Twenty patients with paroxysmal atrial fibrillation and 15 patients with persistent atrial fibrillation enrolled in this study,while 12 patients with sinus rhythms served as controls. The hemodynamic characteristics of the patients in left atrial appendage were measured by transesophageal echocardiography (TEE) and vector flow mapping (VFM) using indicators such as vectors,vortex and energy loss (EL). ① Significant differences appeared between the patients with atrial fibrillation and the controls in heart rate,size of left atrium,size of left atrial appendage (LAA),and velocities of LAA filling and emptying. ② Regular vectors in LAA in early systole and late diastole were found in the patients with paroxysmal atrial fibrillation and the controls; whereas,irregular vectors with direction alternating were visualized in the whole cardiac cycle in the patients with persistent atrial fibrillation. ③ Small vortexes were observed at the opening of the left atrial appendage in late diastole in the patients with paroxysmal atrial fibrillation and the controls. ④ Peak EL values occurred in early systole and late diastole in the patients with paroxysmal atrial fibrillation and the controls. But the patients with persistent atrial fibrillation had increased EL values over the whole cardiac cycle. VFM can visualize and quantify the hemodynamics of LAA in patients with different heart rhythms. It may provide a new method for assessing atrial fibrillation. CopyrightCopyright© by Editorial Board of Journal of Sichuan University (Medical Science Edition).

  8. Etiologic significance of enlargement of the left atrial appendage in adults

    International Nuclear Information System (INIS)

    Green, C.E.; Kelley, M.J.; Higgins, C.B.

    1982-01-01

    Fifty-one patients were divided into two groups: 20 patients with proven rheumatic mitral valve disease (RMVD) and 31 patients with left atrial enlargement (LAE) of a nonrheumatic etiology. The latter group included patients with ischemic papillary muscle dysfunction, mitral valve prolapse, and congestive cardiomyopathy. Radiographic studies showed that enlargement of the left atrial appendage (LAAE) was present in 18 of 20 rheumatics but in only one of 31 nonrheumatics. There was no direct relationship between enlargement of the LAA and radiographic or echocardiographic left atrial size, degree of pulmonary venous hypertension (PVH), or presence of atrial fibrillation. It is postulated that rheumatic influammation of the LAA allows it to dilate out of proportion to the body of the left atrium. In the adult patient with radiographic findings of PVH, LAAE is a valuable and specific radiographic sign of rheumatic mitral valve disease

  9. The Relationship between Left Atrial Mechanical Function and Functional Capacity in Mitral Stenosis

    Directory of Open Access Journals (Sweden)

    Mücahit Yetim

    2013-11-01

    Full Text Available Aim: In this study, left atrial functions of patients with rheumatic mitral stenosis and sinus rhythm, which was determined by transthorasic echocardiography, was compared with those of healhty subjects and the association of left atrial functions with functional capacity was investigated in subgroup analyses.   Material and methods: 32 patients with isolated rheumatic mitral stenosis (median age was 39.1±11  (group 1 and 20 patients in the control group ( median age was 37±8,2 (group 2 were enrolled to study. The average mitral valve area of patients was 1.1±0,3 cm2. When patients were divided according to New York Heart Association (NYHA classification ; 16 patients were NYHA 2 (Grup A and 16 patients were NYHA 3 (Grup B. There were not any asymptomatic patients and no patients were NYHA 4. Left atrium diameters, left atrium volume, left atrium fractional area change and left atrium ejection fractions  of patients in these groups were calculated.   Results: The demographic characteristics of patients is shown in table 1. Left atrium ejection fraction (LAEF and left atrium fractional area change (LAFAC that were determined echocardiographycally were significantly lower in patients with mitral stenosis (32 ± 5, 44 ± 3; p<0.001- 25 ± 11, 32 ± 6; p< 0.02.  When patients were divided according to New York Heart Association (NYHA classification ; 16 patients were NYHA 2 (Grup A and 16 patients were NYHA 3 (Grup B. There were not any asymptomatic patients and no patients were NYHA 4. The clinical and echocardiographic data of patients are shown in table 2. Despite of similar mitral valve area and average mitral gradient ,systolic pulmonary artery pressure was found to be higher in symptomatic group. But there was no difference between left atrial functions of the two groups.   Discussion: In this study we have shown that left atrial functions determined echocardiographically  can decline in patients with mitral stenosis but the

  10. Left Atrial Size and Function in a Canine Model of Chronic Atrial Fibrillation and Heart Failure

    Science.gov (United States)

    Goldberg, Adam; Kusunose, Kenya; Qamruddin, Salima; Rodriguez, L. Leonardo; Mazgalev, Todor N.; Griffin, Brian P.; Van Wagoner, David R.; Zhang, Youhua; Popović, Zoran B.

    2016-01-01

    Background Our aim was to assess how atrial fibrillation (AF) induction, chronicity, and RR interval irregularity affect left atrial (LA) function and size in the setting of underlying heart failure (HF), and to determine whether AF effects can be mitigated by vagal nerve stimulation (VNS). Methods HF was induced by 4-weeks of rapid ventricular pacing in 24 dogs. Subsequently, AF was induced and maintained by atrial pacing at 600 bpm. Dogs were randomized into control (n = 9) and VNS (n = 15) groups. In the VNS group, atrioventricular node fat pad stimulation (310 μs, 20 Hz, 3–7 mA) was delivered continuously for 6 months. LA volume and LA strain data were calculated from bi-weekly echocardiograms. Results RR intervals decreased with HF in both groups (p = 0.001), and decreased further during AF in control group (p = 0.014), with a non-significant increase in the VNS group during AF. LA size increased with HF (p<0.0001), with no additional increase during AF. LA strain decreased with HF (p = 0.025) and further decreased after induction of AF (p = 0.0001). LA strain decreased less (p = 0.001) in the VNS than in the control group. Beat-by-beat analysis showed a curvilinear increase of LA strain with longer preceding RR interval, (r = 0.45, p <0.0001) with LA strain 1.1% higher (p = 0.02) in the VNS-treated animals, independent of preceding RR interval duration. The curvilinear relationship between ratio of preceding and pre-preceding RR intervals, and subsequent LA strain was weaker, (r = 0.28, p = 0.001). However, VNS-treated animals again had higher LA strain (by 2.2%, p = 0.002) independently of the ratio of preceding and pre-preceding RR intervals. Conclusions In the underlying presence of pacing-induced HF, AF decreased LA strain, with little impact on LA size. LA strain depends on the preceding RR interval duration. PMID:26771573

  11. Left atrial appendage: morphology and function in patients with paroxysmal and persistent atrial fibrillation.

    Science.gov (United States)

    Park, Hwan-Cheol; Shin, Jinho; Ban, Ji-Eun; Choi, Jong-Il; Park, Sang-Weon; Kim, Young-Hoon

    2013-04-01

    The anatomical and functional characteristics of the left atrial appendage (LAA) and its relationships with anatomical remodeling and ischemic stroke in patients with atrial fibrillation (AF) have not been clearly established. The purpose of this study was to determine whether functional and morphological features of the LAA independently predict clinical outcome and stroke in patients with AF who underwent catheter ablation (CA). Two hundred sixty-four patients with AF, including 176 with paroxysmal AF (PAF, 54.0 ± 11.4 years old, M:F = 138:38) and 88 with persistent AF (PeAF, 56.4 ± 9.6 years old, M:F = 74:14) were studied. Of these patients, 31 (11.7 %) had a history of stroke/TIA (transient ischemic attack). The LA and LAA volumes were 124.0 ± 42.4 and 24.9 ± 4.3 ml in PeAF, these values were greater than those in PAF (81.2 ± 24.8 ml and 21.2 ± 5.1 ml, P stroke, stroke patients had larger LA volume (106.9 ± 23.0 vs. 94.0 ± 38.9 ml, P = 0.004) and had lower LAA EF (50.0 ± 11.0 vs. 65.7 ± 13.4 %, P stroke were age (P = 0.002) and LAA EF (P stroke/TIA and recurrence of AF after CA in paroxysmal AF patients. Further large scaled prospective study is required for validation.

  12. Left atrial appendage morphology in patients with suspected cardiogenic stroke without known atrial fibrillation.

    Directory of Open Access Journals (Sweden)

    Miika Korhonen

    Full Text Available The left atrial appendage (LAA is the typical origin for intracardiac thrombus formation. Whether LAA morphology is associated with increased stroke/TIA risk is controversial and, if it does, which morphological type most predisposes to thrombus formation. We assessed LAA morphology in stroke patients with cryptogenic or suspected cardiogenic etiology and in age- and gender-matched healthy controls. LAA morphology and volume were analyzed by cardiac computed tomography in 111 patients (74 males; mean age 60 ± 11 years with acute ischemic stroke of cryptogenic or suspected cardiogenic etiology other than known atrial fibrillation (AF. A subgroup of 40 patients was compared to an age- and gender-matched control group of 40 healthy individuals (21 males in each; mean age 54 ± 9 years. LAA was classified into four morphology types (Cactus, ChickenWing, WindSock, CauliFlower modified with a quantitative qualifier. The proportions of LAA morphology types in the main stroke group, matched stroke subgroup, and control group were as follows: Cactus (9.0%, 5.0%, 20.0%, ChickenWing (23.4%, 37.5%, 10.0%, WindSock (47.7%, 35.0%, 67.5%, and CauliFlower (19.8%, 22.5%, 2.5%. The distribution of morphology types differed significantly (P<0.001 between the matched stroke subgroup and control group. The proportion of single-lobed LAA was significantly higher (P<0.001 in the matched stroke subgroup (55% than the control group (6%. LAA volumes were significantly larger (P<0.001 in both stroke study groups compared to controls patients. To conclude, LAA morphology differed significantly between stroke patients and controls, and single-lobed LAAs were overrepresented and LAA volume was larger in patients with acute ischemic stroke of cryptogenic or suspected cardiogenic etiology.

  13. Detection and evaluation of left atrial myxoma by gated radionuclide imaging

    International Nuclear Information System (INIS)

    Sugihara, Hiroki; Adachi, Haruhiko; Nakagawa, Hiroaki

    1985-01-01

    Radionuclide imaging plays an important role in diagnosising left atrial myxoma (LAM). We discussed diagnostic value of Fourier analysis with phase image and evaluated left ventricular filling function using indices such as 1/3 Filling Fraction, Rapid Filling Fraction and Peak Filling Rate derived from left ventricular volume curve. Equillibrium radionuclide angiocardiography was performed in 6 LAM patients. Phase delay in the basal portion of the left ventricle was shown in 5 of 6 LAM patients, and standard deviation of left ventricular phase was larger than these of controls. Left ventricular filling disturbance was suggested in 5 of 6 LAM patients. After surgical remove of myxoma phase delay was disappeared and standard deviation was normalized. And left ventricular filling was improved. We concluded that the phase image of Fourier analysis revealed a left atrial mass prolapsing in the left ventricule during the diastole, and that diastolic indices were useful for left ventricular filling disturbance due to LAM. (author)

  14. Plasmacytoid lymphoma within a left atrial myxoma: a rare coincidental dual pathology.

    Science.gov (United States)

    White, Ralph W; Hirst, Natalie A; Edward, Sara; Nair, Unnikrishnan R

    2010-01-01

    Primary malignant cardiac neoplasms are extremely rare. The occurrence of a malignant lymphoid tumour within a left atrial myxoma is highly atypical, with only one such case previously reported. Here, we describe a patient who presented with symptoms and signs of a left atrial myxoma. Subsequent specimen histology demonstrated the presence of lymphoma within the myxoma. We discuss the importance of histological diagnosis in order to best direct treatment and prognosis of such cases.

  15. Assessment of blood stasis in left-atrial appendage with electron-beam CT: filling delay in atrial fibrillation

    Energy Technology Data Exchange (ETDEWEB)

    Nakanishi, Tadashi [Dept. of Radiology, National Cardiovascular Center, Suita, Osaka (Japan); Hamada, Seiki [Dept. of Radiology, National Cardiovascular Center, Suita, Osaka (Japan); Takamiya, Makoto [Dept. of Radiology, National Cardiovascular Center, Suita, Osaka (Japan); Kuribayashi, Sachio [Dept. of Radiology, National Cardiovascular Center, Suita, Osaka (Japan); Naito, Hiroaki [Biomedical Research Center, Osaka Univ. School of Medicine, Suita (Japan)

    1994-10-01

    The left-atrial appendage (LAA) is the most frequent site of thrombus formation. The most probable reason is its anatomical structure and blood stasis. We hypothesized that peak time delay should occur in the LAA with stagnant blood flow. We measured peak time delay in LAA against left atrium with the flow-mode study of electron-beam CT for 49 patients (including 23 patients with atrial fibrillation [AF]). Volume-mode scannings were also performed to detect intracardiac thrombi. Patients with atrial fibrillation showed a larger value than those with sinus rhythm. Some AF patients with no filling of contrast media into the LAA and/or thrombus showed a larger value than the others. The value obtained by the flow-mode study might have the potential by the flow-mode study might have the potential to assess blood stasis and to predict the jeopardized state in the LAA. (orig.)

  16. Assessment of blood stasis in left-atrial appendage with electron-beam CT: filling delay in atrial fibrillation

    International Nuclear Information System (INIS)

    Nakanishi, Tadashi; Hamada, Seiki; Takamiya, Makoto; Kuribayashi, Sachio; Naito, Hiroaki

    1994-01-01

    The left-atrial appendage (LAA) is the most frequent site of thrombus formation. The most probable reason is its anatomical structure and blood stasis. We hypothesized that peak time delay should occur in the LAA with stagnant blood flow. We measured peak time delay in LAA against left atrium with the flow-mode study of electron-beam CT for 49 patients (including 23 patients with atrial fibrillation [AF]). Volume-mode scannings were also performed to detect intracardiac thrombi. Patients with atrial fibrillation showed a larger value than those with sinus rhythm. Some AF patients with no filling of contrast media into the LAA and/or thrombus showed a larger value than the others. The value obtained by the flow-mode study might have the potential by the flow-mode study might have the potential to assess blood stasis and to predict the jeopardized state in the LAA. (orig.)

  17. Left atrial strain: a new parameter for assessment of left ventricular filling pressure.

    Science.gov (United States)

    Cameli, Matteo; Mandoli, Giulia Elena; Loiacono, Ferdinando; Dini, Frank Lloyd; Henein, Michael; Mondillo, Sergio

    2016-01-01

    In order to obtain accurate diagnosis, treatment and prognostication in many cardiac conditions, there is a need for assessment of left ventricular (LV) filling pressure. While systole depends on ejection function of LV, diastole and its disturbances influence filling function and pressures. The commonest condition that represents the latter is heart failure with preserved ejection fraction in which LV ejection is maintained, but diastole is disturbed and hence filling pressures are raised. Significant diastolic dysfunction results in raised LV end-diastolic pressure, mean left atrial (LA) pressure and pulmonary capillary wedge pressure, all referred to as LV filling pressures. Left and right heart catheterization has traditionally been used as the gold standard investigation for assessing these pressures. More recently, Doppler echocardiography has taken over such application because of its noninvasive nature and for being patient friendly. A number of indices are used to achieve accurate assessment of filling pressures including: LV pulsed-wave filling velocities (E/A ratio, E wave deceleration time), pulmonary venous flow (S wave and D wave), tissue Doppler imaging (E' wave and E/E' ratio) and LA volume index. LA longitudinal strain derived from speckle tracking echocardiography (STE) is also sensitive in estimating intracavitary pressures. It is angle-independent, thus overcomes Doppler limitations and provides highly reproducible measures of LA deformation. This review examines the application of various Doppler echocardiographic techniques in assessing LV filling pressures, in particular the emerging role of STE in assessing LA pressures in various conditions, e.g., HF, arterial hypertension and atrial fibrillation.

  18. Effects of sedation on echocardiographic variables of left atrial and left ventricular function in healthy cats.

    Science.gov (United States)

    Ward, Jessica L; Schober, Karsten E; Fuentes, Virginia Luis; Bonagura, John D

    2012-10-01

    Although sedation is frequently used to facilitate patient compliance in feline echocardiography, the effects of sedative drugs on echocardiographic variables have been poorly documented. This study investigated the effects of two sedation protocols on echocardiographic indices in healthy cats, with special emphasis on the assessment of left atrial size and function, as well as left ventricular diastolic performance. Seven cats underwent echocardiography (transthoracic two-dimensional, spectral Doppler, color flow Doppler and tissue Doppler imaging) before and after sedation with both acepromazine (0.1 mg/kg IM) and butorphanol (0.25 mg/kg IM), or acepromazine (0.1 mg/kg IM), butorphanol (0.25 mg/kg IM) and ketamine (1.5 mg/kg IV). Heart rate increased significantly following acepromazine/butorphanol/ketamine (mean±SD of increase, 40±26 beats/min) and non-invasive systolic blood pressure decreased significantly following acepromazine/butorphanol (mean±SD of decrease, 12±19 mmHg). The majority of echocardiographic variables were not significantly different after sedation compared with baseline values. Both sedation protocols resulted in mildly decreased left ventricular end-diastolic dimension and mildly increased left ventricular end-diastolic wall thickness. This study therefore failed to demonstrate clinically meaningful effects of these sedation protocols on echocardiographic measurements, suggesting that sedation with acepromazine, butorphanol and/or ketamine can be used to facilitate echocardiography in healthy cats.

  19. Psoriasis is associated with subsequent atrial fibrillation in hypertensive patients with left ventricular hypertrophy

    DEFF Research Database (Denmark)

    Bang, Casper N; Okin, Peter M; Køber, Lars

    2014-01-01

    BACKGROUND: Inflammation contributes to the pathogenesis of psoriasis as well as atrial fibrillation. The impact of psoriasis and its association with new-onset atrial fibrillation was assessed in hypertensive patients with left ventricular hypertrophy (LVH). METHODS: The predictive value...... or developed psoriasis and new-onset atrial fibrillation occurred in 506 patients (7.1%) during a mean follow-up of 4.7 ± 1.1 years. At baseline, the psoriasis patients were younger (65 ± 7 vs. 67 ± 7 years) and had less left ventricle hypertrophy by ECG Sokolow-Lyon voltage (27.6 ± 9.7 vs. 30.1 ± 10.4 mm...... of baseline or incident psoriasis for new-onset atrial fibrillation was evaluated in 7099 hypertensive patients with electrocardiographic LVH with no history of atrial fibrillation or other cardiovascular disease, in sinus rhythm on their baseline electrocardiogram. RESULTS: A total of 154 patients (2.2%) had...

  20. Inadvertent puncture of the aortic noncoronary cusp during postoperative left atrial tachycardia ablation

    Directory of Open Access Journals (Sweden)

    Dursun Aras, MD

    2015-08-01

    Full Text Available Transseptal catheterization has become part of the interventional electrophysiologist׳s technical armamentarium since the development of left atrial catheter ablation and percutaneous technologies for treating mitral and aortic valve disease. Although frequently performed, the procedure׳s most feared complication is aortic root penetration. Focal atrial tachycardia has been described as the most common late sequela of surgical valve replacements. We present a complicated case involving the inadvertent delivery of an 8 French sheath across the noncoronary cusp during radiofrequency catheter ablation for left atrial tachycardia originating from the mitral annulus in a patient with prior mitral valve replacement.

  1. Clinical impact of quantitative left atrial vortex flow analysis in patients with atrial fibrillation: a comparison with invasive left atrial voltage mapping.

    Science.gov (United States)

    Lee, Jung Myung; Hong, Geu-Ru; Pak, Hui-Nam; Shim, Chi Young; Houle, Helene; Vannan, Mani A; Kim, Minji; Chung, Namsik

    2015-08-01

    Recently, left atrial (LA) vortex flow analysis using contrast transesophageal echocardiography (TEE) has been shown to be feasible and has demonstrated significant differences in vortex flow morphology and pulsatility between normal subjects and patients with atrial fibrillation (AF). However, the relationship between LA vortex flow and electrophysiological properties and the clinical significance of LA vortex flow are unknown. The aims of this study were (1) to compare LA vortex flow parameters with LA voltage and (2) to assess the predictive value of LA vortex flow parameters for the recurrence of AF after radiofrequency catheter ablation (RFCA). Thirty-nine patients with symptomatic non-valvular AF underwent contrast TEE before undergoing RFCA for AF. Quantitative LA vortex flow parameters were analyzed by Omega flow (Siemens Medical Solution, Mountain View, CA, USA). The morphology and pulsatility of LA vortex flow were compared with electrophysiologic parameters that were measured invasively. Hemodynamic, electrophysiological, and vortex flow parameters were compared between patients with and without early recurrence of AF after RFCA. Morphologic parameters, including LA vortex depth, length, width, and sphericity index were not associated with LA voltage or hemodynamic parameters. The relative strength (RS), which represents the pulsatility power of LA, was positively correlated with LA voltage (R = 0.53, p = 0.01) and LA appendage flow velocity (R = 0.73, p vortex flow analysis, especially RS, correlated well with LA voltage. Decreased pulsatility strength in the LA was associated with recurrent AF. LA vortex may have incremental value in predicting the recurrence of AF.

  2. Left atrial appendage function in prediction of paroxysmal atrial fibrilation in patients with untreated hypertension.

    Science.gov (United States)

    Tenekecioglu, Erhan; Agca, Fahriye Vatansever; Karaagac, Kemal; Ozluk, Ozlem Arican; Peker, Tezcan; Kuzeytemiz, Mustafa; Senturk, Muhammed; Yılmaz, Mustafa

    2014-01-01

    Abstract The onset of AF results in a significant increase in mortality rates and morbidity in hypertensive patients and this rhythm disorder exposes patients to a significantly increased risk of cerebral or peripheral embolisms. Tissue Doppler imaging was found to be useful in early detection of myocardial dysfunction in several diseases. It was shown that tissue Doppler analysis of the walls of the left atrial appendage (LAA) can give accurate information about the function of the LAA in hypertensive patients. In this study, we aimed to investigate and identify the specific predictive parameters for the onset of AF in patients with hypertension with tissue Doppler imaging of LAA. We studied age and sex matched 57 untreated hypertensive patients with paroxysmal atrial fibrillation (PAF) and 27 untreated hypertensive subjects without PAF. With transthoracic echocardiography, diastolic mitral A-velocity and LA maximal volume index which reflects reservoir function of left atrium was measured, with transesophageal echocardiography, LAA emptying velocity (LAA-PW D2) and tissue Doppler contracting velocity of LAA (LAA-TDI-D2) were measured. LA maximal volume index of the groups (22.28 ± 3.59 mL/m(2) in Group 1 versus 20.37 ± 3.97 mL/m(2) in Group 2, p = 0.07) and diastolic mitral A-velocity [0.93 (0.59-1.84) m/s in patients with PAF versus 0.90 (0.62-1.76) m/s in patients without PAF, p = 0.26] was not significantly different between study groups, during TEE, LAA-PW D2 (0.31 ± 0.04 m/s in Group 1 versus 0.33 ± 0.03 m/s in Group 2, p = 0.034) and LAA-TDI-D2 (0.18 ± 0.04 m/s in Group 1 versus 0.21 ± 0.05 m/s in Group 2, p = 0.014) were significantly decreased in Group 1. In this study, we found that in hypertensive PAF patients despite normal global LA functions, LAA contracting function was deteriorated. Tissue Doppler analysis of LAA is clinically usefull approach to detect the risk of developing PAF in

  3. Changes in left atrial deformation in hypertrophic cardiomyopathy: Evaluation by vector velocity imaging

    Directory of Open Access Journals (Sweden)

    Hala Mahfouz Badran

    2012-12-01

    Full Text Available Objectives: Hypertrophic cardiomyopathy (HCM represents a generalized myopathic process affecting both ventricular and atrial myocardium. We assessed the global and regional left atrial (LA function and its relation to left ventricular (LV mechanics and clinical status in patients with HCM using Vector Velocity Imaging (VVI. Methods: VVI of the LA and LV was acquired from apical four- and two-chamber views of 108 HCM patients (age 40±19years, 56.5% men and 33 healthy subjects, all had normal LV systolic function. The LA subendocardium was traced to obtain atrial volumes, ejection fraction, velocities, and strain (ɛ/strain rate (SR measurements. Results: Left atrial reservoir (ɛsys,SRsys and conduit (early diastolic SRe function were significantly reduced in HCM compared to controls (P-1.8s-1 was 81% sensitive and 30% specific, SRa>-1.5s-1 was 73% sensitive and 40% specific. By multivariate analysis global LVɛsys and LV septal thickness are independent predictors for LAɛsys, while end systolic diameter is the only independent predictor for SRsys, P<.001. Conclusion: Left atrial reservoir and conduit function as measured by VVI were significantly impaired while contractile function was preserved among HCM patients. Left atrial deformation was greatly influenced by LV mechanics and correlated to severity of phenotype.

  4. Changes in left atrial deformation in hypertrophic cardiomyopathy: Evaluation by vector velocity imaging

    Science.gov (United States)

    Badran, Hala Mahfouz; Soltan, Ghada; Hassan, Hesham; Nazmy, Ahmed; Faheem, Naglaa; Saadan, Haythem; Yacoub, Magdi H.

    2012-01-01

    Abstract: Objectives: Hypertrophic cardiomyopathy (HCM) represents a generalized myopathic process affecting both ventricular and atrial myocardium. We assessed the global and regional left atrial (LA) function and its relation to left ventricular (LV) mechanics and clinical status in patients with HCM using Vector Velocity Imaging (VVI). Methods: VVI of the LA and LV was acquired from apical four- and two-chamber views of 108 HCM patients (age 40 ± 19years, 56.5% men) and 33 healthy subjects, all had normal LV systolic function. The LA subendocardium was traced to obtain atrial volumes, ejection fraction, velocities, and strain (ϵ)/strain rate (SR) measurements. Results: Left atrial reservoir (ϵsys,SRsys) and conduit (early diastolic SRe) function were significantly reduced in HCM compared to controls (P  − 1.8s− 1 was 81% sensitive and 30% specific, SRa> − 1.5s− 1 was 73% sensitive and 40% specific. By multivariate analysis global LVϵsys and LV septal thickness are independent predictors for LAϵsys, while end systolic diameter is the only independent predictor for SRsys, P < .001. Conclusion: Left atrial reservoir and conduit function as measured by VVI were significantly impaired while contractile function was preserved among HCM patients. Left atrial deformation was greatly influenced by LV mechanics and correlated to severity of phenotype. PMID:24688992

  5. Early Heparin Administration Reduces Risk for Left Atrial Thrombus Formation during Atrial Fibrillation Ablation Procedures

    Directory of Open Access Journals (Sweden)

    Stefan Asbach

    2011-01-01

    Full Text Available Objective. Despite the use of anticoagulation during left atrial (LA ablation procedures, ischemic cerebrovascular accidents (CVAs are recognized as a serious complication. Heparin is usually given after safe transseptal access has been obtained, resulting in a short unprotected dwell time of catheters within the LA, which may account for CVAs. We investigated the frequency of CVAs and LA thrombus formation as detected by intracardiac ultrasound (ICE depending on the timing of heparin administration. Methods and Results. Sixty LA ablation procedures with the use of ICE were performed in 55 patients. Patients were grouped by heparin administration after (Group I, =13 and before (Group II, =47 transseptal access. Group I patients were younger (56.6±13.7 versus 65.9±9.9 years, =.01; other clinical and echocardiographic characteristics did not differ between groups. Early thrombus formation was observed in 2 (15.4% of group I patients as compared to 0% of group II patients (=.04. One CVA (2.1% occurred in one group II patient without prior thrombus detection, and none occurred in group I patients (=ns. Conclusion. Early administration of heparin reduces the risk of early intracardiac thrombus formation during LA ablation procedures. This did not result in reduced rate of CVAs.

  6. Left atrial ejection force predicts the outcome after catheter ablation for paroxysmal atrial fibrillation.

    Science.gov (United States)

    Kishima, Hideyuki; Mine, Takanao; Takahashi, Satoshi; Ashida, Kenki; Ishihara, Masaharu; Masuyama, Tohru

    2018-02-01

    Left atrium (LA) systolic dysfunction is observed in the early stages of atrial fibrillation (AF) prior to LA anatomical change. We investigated whether LA systolic dysfunction predicts recurrent AF after catheter ablation (CA) in patients with paroxysmal AF. We studied 106 patients who underwent CA for paroxysmal AF. LA systolic function was assessed with the LA emptying volume = Maximum LA volume (LAV max ) - Minimum LA volume (LAV min ), LA emptying fraction = [(LAV max - LAV min )/LAV max ] × 100, and LA ejection force calculated with Manning's method [LA ejection force = (0.5 × ρ × mitral valve area × A 2 )], where ρ is the blood density and A is the late-diastolic mitral inflow velocity. Recurrent AF was detected in 35/106 (33%) during 14.6 ± 9.1 months. Univariate analysis revealed reduced LA ejection force, decreased LA emptying fraction, larger LA diameter, and elevated brain natriuretic peptide as significant variables. On multivariate analysis, reduced LA ejection force and larger LA diameter were independently associated with recurrent AF. Moreover, patients with reduced LA ejection force and larger LA diameter had a higher risk of recurrent AF than preserved LA ejection force (log-rank P = 0.0004). Reduced LA ejection force and larger LA diameter were associated with poor outcome after CA for paroxysmal AF, and could be a new index to predict recurrent AF. © 2017 Wiley Periodicals, Inc.

  7. The effect of percutaneous transcatheter occlusion of left atrial appendage on left atrium and adjacent anatomic structure in canine

    International Nuclear Information System (INIS)

    Yang Zhihong; Wu Hong; Qin Yongwen; Hu Jianqiang; Ding Zhongru; Liu Zongjun; Liu Biao; Zheng Xing

    2009-01-01

    Objective: To observe the effect of percutaneous transcatheter occlusion of left atrial appendage (LAA) with a new self-manufactured LAA occluder on left atrium and adjacent anatomic structure in canine. Methods: A new self-manufactured LAA occluder was implanted into the LAA through a transseptal catheter in 20 dogs. Before and after the procedure, the experimental dogs were anaesthetized and examined by transthoracic echocardiography (TTE) to measure the diameter and the volume of the left atrium, the left superior pulmonary vein flow velocity and the left atrioventricular valve flow velocity separately. The contrast radiography of the LAA and the left coronary arteriography were performed. Results: The new LAA occluder was implanted successfully in 14 dogs. No obvious changes in the diameter and the volume of the left atrium, in left superior pulmonary vein flow velocity and in left atrioventricular valve flow velocity were found. On arteriography, left circumflex artery was normally displayed after the procedure. No migration of the occluder was seen on TTE and angiography after procedure. Conclusion: Percutaneous transcatheter occlusion of left atrial appendage with a new self-manufactured LAA occluder has no obvious effect on left atrium and adjacent anatomic structure in experimental canine, which indicates that the new-type device is a safe and feasible occluder for LAA. (authors)

  8. Effect of Left Ventricular Outflow Tract Obstruction on Left Atrial Mechanics in Hypertrophic Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Lynne K. Williams

    2015-01-01

    Full Text Available Left atrial (LA volumes are known to be increased in hypertrophic cardiomyopathy (HCM and are a predictor of adverse outcome. In addition, LA function is impaired and is presumed to be due to left ventricular (LV diastolic dysfunction as a result of hypertrophy and myocardial fibrosis. In the current study, we assess the incremental effect of outflow tract obstruction (and concomitant mitral regurgitation on LA function as assessed by LA strain. Patients with HCM (50 obstructive, 50 nonobstructive were compared to 50 normal controls. A subset of obstructive patients who had undergone septal myectomy was also studied. Utilising feature-tracking software applied to cardiovascular magnetic resonance images, LA volumes and functional parameters were calculated. LA volumes were significantly elevated and LA ejection fraction and strain were significantly reduced in patients with HCM compared with controls and were significantly more affected in patients with obstruction. LA volumes and function were significantly improved after septal myectomy. LVOT obstruction and mitral regurgitation appear to further impair LA mechanics. Septal myectomy results in a significant reduction in LA volumes, paralleled by an improvement in function.

  9. Left-to-Right Atrial Inward Rectifier Potassium Current Gradients in Patients With Paroxysmal Versus Chronic Atrial Fibrillation

    Science.gov (United States)

    Voigt, Niels; Trausch, Anne; Knaut, Michael; Matschke, Klaus; Varró, András; Van Wagoner, David R.; Nattel, Stanley; Ravens, Ursula; Dobrev, Dobromir

    2018-01-01

    Background Recent evidence suggests that atrial fibrillation (AF) is maintained by high-frequency reentrant sources with a left-to-right–dominant frequency gradient, particularly in patients with paroxysmal AF (pAF). Unequal left-to-right distribution of inward rectifier K+ currents has been suggested to underlie this dominant frequency gradient, but this hypothesis has never been tested in humans. Methods and Results Currents were measured with whole-cell voltage-clamp in cardiomyocytes from right atrial (RA) and left (LA) atrial appendages of patients in sinus rhythm (SR) and patients with AF undergoing cardiac surgery. Western blot was used to quantify protein expression of IK1 (Kir2.1 and Kir2.3) and IK,ACh (Kir3.1 and Kir3.4) subunits. Basal current was ≈2-fold larger in chronic AF (cAF) versus SR patients, without RA-LA differences. In pAF, basal current was ≈2-fold larger in LA versus RA, indicating a left-to-right atrial gradient. In both atria, Kir2.1 expression was ≈2-fold greater in cAF but comparable in pAF versus SR. Kir2.3 levels were unchanged in cAF and RA-pAF but showed a 51% decrease in LA-pAF. In SR, carbachol-activated (2 μmol/L) IK,ACh was 70% larger in RA versus LA. This right-to-left atrial gradient was decreased in pAF and cAF caused by reduced IK,ACh in RA only. Similarly, in SR, Kir3.1 and Kir3.4 proteins were greater in RA versus LA and decreased in RA of pAF and cAF. Kir3.1 and Kir3.4 expression was unchanged in LA of pAF and cAF. Conclusions Our results support the hypothesis that a left-to-right gradient in inward rectifier background current contributes to high-frequency sources in LA that maintain pAF. These findings have potentially important implications for development of atrial-selective therapeutic approaches. PMID:20657029

  10. Percutaneous closure of the left atrial appendage in patients with diabetes mellitus.

    Science.gov (United States)

    Azizy, Obayda; Rammos, Christos; Lehmann, Nils; Rassaf, Tienush; Kälsch, Hagen

    2017-09-01

    Left atrial appendage closure is a preventive treatment of atrial fibrillation-related thrombo-embolism. Patients with diabetes mellitus have increased risk for a negative outcome in percutaneous cardiac interventions. We assessed whether percutaneous left atrial appendage closure is safe and effective in patients with diabetes mellitus. We included 78 patients (mean age of 74.4 ± 8.3 years) with indication for left atrial appendage closure in an open-label observational single-centre study. Patients with diabetes mellitus ( n = 31) were at higher thrombo-embolic and bleeding risk (CHA 2 DS 2 -VASc: 4.5 ± 0.9, HAS-BLED: 4.7 ± 0.7) compared to patients without diabetes mellitus ( n = 47, CHA 2 DS 2 -VASc: 3.5 ± 1.0, HAS-BLED: 4.1 ± 0.8; p diabetes mellitus (Euro II-Score: 6.6 ± 3.7 vs 3.9 ± 1.9, p diabetes mellitus had no events ( p = 0.672). Follow-up of 6 months revealed no bleeding complication in both groups. No stroke occurred in follow-up, and left atrial appendage flow velocity reduction (55.6 ± 38.6 vs 51.4 ± 19.1 cm/s, p = 0.474) and rate of postinterventional leakage in the left atrial appendage were comparable (0% vs 2.1%, p = 0.672). Despite patients with diabetes mellitus are high-risk patients, the outcome of percutaneous left atrial appendage closure is similar to patients without diabetes mellitus.

  11. A Case of Atrial Tachycardia Circulating around a Left Atrial Roof Scar with Diabetes Mellitus and Renal Failure on Hemodialysis

    Directory of Open Access Journals (Sweden)

    Naoko Hijioka

    2016-01-01

    Full Text Available Introduction. Little is known about the effects of volume change by hemodialysis (HD and mechanical stress caused by an anatomical structure being in contact with the left atrium on the progression of atrial remodeling. We experienced a case of atrial tachycardia (AT in a patient who had left atrial (LA scarring at the LA roof and a low-voltage area with slow conduction around the LA scar as components of AT circuit. Here, we present the conceivable hypothesis of the LA scar and the low-voltage area formation. Our concept can be useful in developing a strategy for ablation in a patient with chronic renal failure (CRF on HD. Case Report. A 65-year-old man with CRF on HD was referred for AT ablation. Three-dimensional electroanatomical mapping revealed that the AT conducted around an LA scar in a counterclockwise fashion. There was a slow conduction area at the superior side of the LA scar, where the AT was terminated during the ablation. Computed tomography indicated a close relationship between the LA and the anatomical structures (ascending aorta and pulmonary artery. Conclusion. Volume change by HD and close contact of anatomical structures to the LA can promote atrial remodeling, resulting in AT occurrence.

  12. Brain ischemia as initial sign of a left atrial myxoma Report of one case

    International Nuclear Information System (INIS)

    Osio, Luis F; Velasquez, Jorge E; Tobon, Gabriel J; Posada, Gloria; Contreras, Eduardo; Sanchez, Jairo; Gutierrez, Javier

    2008-01-01

    Primary heart tumors are rare; 75% of them are benign and almost half of the benign ones are myxomas that in most cases are located in the left cavities. Clinical manifestations of myxomas depend on its localization site. Nevertheless, it is accepted that brain ischemia is the initial clinical manifestation in a third of atrial myxomas. The case of a 65 years ald male patient in whom the first clinical manifestation of an atrial myxoma was an ischemic cerebrovascular event, is presented

  13. The imaging features of neurologic complications of left atrial myxomas

    International Nuclear Information System (INIS)

    Liao, Wei-Hua; Ramkalawan, Divya; Liu, Jian-Ling; Shi, Wei; Zee, Chi-Shing; Yang, Xiao-Su; Li, Guo-Liang; Li, Jing; Wang, Xiao-Yi

    2015-01-01

    Background: Neurologic complications may be the first symptoms of atrial myxomas. Understanding the imaging features of neurologic complications of atrial myxomas can be helpful for the prompt diagnosis. Objective: To identify neuroimaging features for patients with neurologic complications attributed to atrial myxoma. Methods: We retrospectively reviewed the medical records of 103 patients with pathologically confirmed atrial myxoma at Xiangya Hospital from January 2009 to January 2014. The neuroimaging data for patients with neurologic complications were analyzed. Results: Eight patients with atrial myxomas (7.77%) presented with neurologic manifestations, which constituted the initial symptoms for seven patients (87.5%). Neuroimaging showed five cases of cerebral infarctions and three cases of aneurysms. The main patterns of the infarctions were multiplicity (100.0%) and involvement of the middle cerebral artery territory (80.0%). The aneurysms were fusiform in shape, multiple in number (100.0%) and located in the distal middle cerebral artery (100.0%). More specifically, high-density in the vicinity of the aneurysms was observed on CT for two patients (66.7%), and homogenous enhancement surrounding the aneurysms was detected in the enhanced imaging for two patients (66.7%). Conclusion: Neurologic complications secondary to atrial myxoma consist of cerebral infarctions and aneurysms, which show certain characteristic features in neuroimaging. Echocardiography should be performed in patients with multiple cerebral infarctions, and multiple aneurysms, especially when aneurysms are distal in location. More importantly, greater attention should be paid to the imaging changes surrounding the aneurysms when myxomatous aneurysms are suspected and these are going to be the relevant features in our article

  14. The imaging features of neurologic complications of left atrial myxomas

    Energy Technology Data Exchange (ETDEWEB)

    Liao, Wei-Hua; Ramkalawan, Divya; Liu, Jian-Ling; Shi, Wei [Department of Radiology, Xiangya Hospital, Central South University, Changsha 410008, Hunan (China); Zee, Chi-Shing [Department of Radiology, Keck School of Medicine, University of Southern California, Los Angeles, CA 90033 (United States); Yang, Xiao-Su; Li, Guo-Liang; Li, Jing [Department of Neurology, Xiangya Hospital, Central South University, Changsha 410008, Hunan (China); Wang, Xiao-Yi, E-mail: cjr.wangxiaoyi@vip.163.com [Department of Radiology, Xiangya Hospital, Central South University, Changsha 410008, Hunan (China)

    2015-05-15

    Background: Neurologic complications may be the first symptoms of atrial myxomas. Understanding the imaging features of neurologic complications of atrial myxomas can be helpful for the prompt diagnosis. Objective: To identify neuroimaging features for patients with neurologic complications attributed to atrial myxoma. Methods: We retrospectively reviewed the medical records of 103 patients with pathologically confirmed atrial myxoma at Xiangya Hospital from January 2009 to January 2014. The neuroimaging data for patients with neurologic complications were analyzed. Results: Eight patients with atrial myxomas (7.77%) presented with neurologic manifestations, which constituted the initial symptoms for seven patients (87.5%). Neuroimaging showed five cases of cerebral infarctions and three cases of aneurysms. The main patterns of the infarctions were multiplicity (100.0%) and involvement of the middle cerebral artery territory (80.0%). The aneurysms were fusiform in shape, multiple in number (100.0%) and located in the distal middle cerebral artery (100.0%). More specifically, high-density in the vicinity of the aneurysms was observed on CT for two patients (66.7%), and homogenous enhancement surrounding the aneurysms was detected in the enhanced imaging for two patients (66.7%). Conclusion: Neurologic complications secondary to atrial myxoma consist of cerebral infarctions and aneurysms, which show certain characteristic features in neuroimaging. Echocardiography should be performed in patients with multiple cerebral infarctions, and multiple aneurysms, especially when aneurysms are distal in location. More importantly, greater attention should be paid to the imaging changes surrounding the aneurysms when myxomatous aneurysms are suspected and these are going to be the relevant features in our article.

  15. Echocardiographic reference ranges for normal left atrial function parameters: results from the EACVI NORRE study.

    Science.gov (United States)

    Sugimoto, Tadafumi; Robinet, Sébastien; Dulgheru, Raluca; Bernard, Anne; Ilardi, Federica; Contu, Laura; Addetia, Karima; Caballero, Luis; Kacharava, George; Athanassopoulos, George D; Barone, Daniele; Baroni, Monica; Cardim, Nuno; Hagendorff, Andreas; Hristova, Krasimira; Lopez, Teresa; de la Morena, Gonzalo; Popescu, Bogdan A; Penicka, Martin; Ozyigit, Tolga; Rodrigo Carbonero, Jose David; van de Veire, Nico; Von Bardeleben, Ralph Stephan; Vinereanu, Dragos; Zamorano, Jose Luis; Go, Yun Yun; Marchetta, Stella; Nchimi, Alain; Rosca, Monica; Calin, Andreea; Moonen, Marie; Cimino, Sara; Magne, Julien; Cosyns, Bernard; Galli, Elena; Donal, Erwan; Habib, Gilbert; Esposito, Roberta; Galderisi, Maurizio; Badano, Luigi P; Lang, Roberto M; Lancellotti, Patrizio

    2018-02-23

    To obtain the normal ranges for echocardiographic measurements of left atrial (LA) function from a large group of healthy volunteers accounting for age and gender. A total of 371 (median age 45 years) healthy subjects were enrolled at 22 collaborating institutions collaborating in the Normal Reference Ranges for Echocardiography (NORRE) study of the European Association of Cardiovascular Imaging (EACVI). Left atrial data sets were analysed with a vendor-independent software (VIS) package allowing homogeneous measurements irrespective of the echocardiographic equipment used to acquire data sets. The lowest expected values of LA function were 26.1%, 48.7%, and 41.4% for left atrial strain (LAS), 2D left atrial emptying fraction (LAEF), and 3D LAEF (reservoir function); 7.7%, 24.2%, and -0.53/s for LAS-active, LAEF-active, and LA strain rate during LA contraction (SRa) (pump function) and 12.0% and 21.6% for LAS-passive and LAEF-passive (conduit function). Left atrial reservoir and conduit function were decreased with age while pump function was increased. All indices of reservoir function and all LA strains had no difference in both gender and vendor. However, inter-vendor differences were observed in LA SRa despite the use of VIS. The NORRE study provides contemporary, applicable echocardiographic reference ranges for LA function. Our data highlight the importance of age-specific reference values for LA functions.

  16. Paroxysmal postprandial atrial fibrilation suppressed by laparoscopic repair of a giant paraesophageal hernia compressing the left atrium.

    Science.gov (United States)

    Cristian, Daniel A; Constantin, Alin S; Barbu, Mariana; Spătaru, Dan; Burcoș, Traean; Grama, Florin A

    2015-03-01

    We present the case of a patient with a giant paraesophageal hernia associated with paroxysmal postprandial atrial fibrillation that was suppressed after surgery. The imaging investigations showed the intrathoracic displacement of a large part of the stomach, which pushed the left atrial wall causing atrial fibrillation. The laparoscopic surgical repair acted as sole treatment for this condition.

  17. Validation of Left Atrial Volume Estimation by Left Atrial Diameter from the Parasternal Long-Axis View.

    Science.gov (United States)

    Canciello, Grazia; de Simone, Giovanni; Izzo, Raffaele; Giamundo, Alessandra; Pacelli, Filomena; Mancusi, Costantino; Galderisi, Maurizio; Trimarco, Bruno; Losi, Maria-Angela

    2017-03-01

    Measurement of left atrial (LA) volume (LAV) is recommended for quantification of LA size. Only LA anteroposterior diameter (LAd) is available in a number of large cohorts, trials, or registries. The aim of this study was to evaluate whether LAV may be reasonably estimated from LAd. One hundred forty consecutive patients referred to our outpatient clinics were prospectively enrolled to measure LAd from the long-axis view on two-dimensional echocardiography. LA orthogonal dimensions were also taken from apical four- and two-chamber views. LAV was measured using the Simpson, area-length, and ellipsoid (LAV e ) methods. The first 70 patients were the learning series and the last 70 the testing series (TeS). In the learning series, best-fitting regression analysis of LAV-LAd was run using all LAV methods, and the highest values of F were chosen among the regression equations. In the TeS, the best-fitting regressions were used to estimate LAV from LAd. In the learning series, the best-fitting regression was linear for the Spearman method (r 2  = 0.62, F = 111.85, P = .0001) and area-length method (r 2  = 0.62, F = 112.24, P = .0001) and powered for the LAV e method (r 2  = 0.81, F = 288.41, P = .0001). In the TeS, the r 2 value for LAV prediction was substantially better using the LAV e method (r 2  = 0.89) than the Simpson (r 2  = 0.72) or area-length (r 2  = 0.70) method, as was the intraclass correlation (ρ = 0.96 vs ρ = 0.89 and ρ = 0.89, respectively). In the TeS, the sensitivity and specificity of LA dilatation by the estimated LAV e method were 87% and 90%, respectively. LAV can be estimated from LAd using a nonlinear equation with an elliptical model. The proposed method may be used in retrospective analysis of existing data sets in which determination of LAV was not programmed. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  18. Clinical application of percutaneous balloon mitral valvuloplasty in patients with rheumatic mitral stenosis and left atrial thrombi

    International Nuclear Information System (INIS)

    Chen Junzhu; Zhang Furong; Tao Qianmin; Cheng Guanchang; Zheng Liangrong; Zhu Jianhua

    2002-01-01

    Objective: To evaluate safety and effect of percutaneous balloon mitral valvuloplasty (PBMV) for patients with rheumatic mitral stenosis and left atrial thrombi. Methods: PBMV was performed in 27 patients with rheumatic mitral stenosis and left atrial thrombi. 19 cases of left atrial fresh thrombi revealed by trans-esophageal echocardiography (TEE) received warfarin orally for 3-6 months before PBMV. Results: PBMV was successful in all cases of mitral stenosis and left atrial thrombi. Left atrial fresh thrombi was completely resolved in 9 cases and became smaller chronic organized thrombi in 10 cases after warfarin anticoagulation treatment among 19 cases of left atrial fresh thrombi revealed by TEE. In 5 cases of left atrial chronic organized thrombi shown only transthoracic echocardiography and without anticoagulation treatment, one case had cerebral embolism. No complication occurred in other cases. Conclusions: The study showed that patients with rheumatic mitral stenosis and atrial fibrillation should have routine TEE. PBMV for rheumatic mitral stenosis with left atrial thrombi after anticoagulation treatment is safe and effective

  19. Rare Chronic Gastric Volvulus Associated with Left Atrial and Mediastinal Compression

    OpenAIRE

    Shriki, Jabi E.; Nguyen, Khanh; Rozo, Juan Carlos; Reul, George J.; Mortazavi, Ali

    2002-01-01

    We report a case of chronic gastric volvulus associated with left atrial compression in a 75-year-old woman who presented with chest pain, shortness of breath, and hypotension after elective hemiarthroplasty of the left hip. The patient's medical history included a paraesophageal hernia and gastric volvulus diagnosed in 1997 but left untreated. The present diagnosis of gastric volvulus was made on the basis of a chest radiograph and subsequent computed tomography. Echocardiography showed the ...

  20. Obese Hypertensive Men Have Lower Circulating Proatrial Natriuretic Peptide Concentrations Despite Greater Left Atrial Size

    DEFF Research Database (Denmark)

    Asferg, Camilla L; Andersen, Ulrik B; Linneberg, Allan

    2018-01-01

    BACKGROUND: Obese persons have lower circulating natriuretic peptide (NP) concentrations. It has been proposed that this natriuretic handicap plays a role in obesity-related hypertension. In contrast, hypertensive patients with left atrial enlargement have higher circulating NP concentrations....... On this background, we investigated whether obese hypertensive men could have lower circulating NP concentrations despite evidence of pressure-induced greater left atrial size. METHODS: We examined 98 obese men (body mass index [BMI] ≥ 30.0 kg/m2) and 27 lean normotensive men (BMI 20.0-24.9 kg/m2). All men were...... using echocardiography, and we measured fasting serum concentrations of midregional proatrial NP (MR-proANP). RESULTS: Of the 98 obese men, 62 had hypertension and 36 were normotensive. The obese hypertensive men had greater left atrial size (mean ± SD: 28.7 ± 6.0 ml/m2) compared with the lean...

  1. Left Atrial Enlargement in Young High-Level Endurance Athletes – Another Sign of Athlete’s Heart?

    Directory of Open Access Journals (Sweden)

    Król Wojciech

    2016-12-01

    Full Text Available Enlargement of the left atrium is perceived as a part of athlete’s heart syndrome, despite the lack of evidence. So far, left atrial size has not been assessed in the context of exercise capacity. The hypothesis of the present study was that LA enlargement in athletes was physiological and fitness-related condition. In addition, we tried to assess the feasibility and normal values of left atrial strain parameters and their relationship with other signs of athlete’s heart. The study group consisted of 114 international-level rowers (17.5 ± 1.5 years old; 46.5% women. All participants underwent a cardio-pulmonary exercise test and resting transthoracic echocardiography. Beside standard echocardiographic measurements, two dimensional speckle tracking echocardiography was used to assess average peak atrial longitudinal strain, peak atrial contraction strain and early left atrial diastolic longitudinal strain. Mild, moderate and severe left atrial enlargement was present in 27.2°%, 11.4% and 4.4% athletes, respectively. There were no significant differences between subgroups with different range of left atrial enlargement in any of echocardiographic parameters of the left ventricle diastolic function, filling pressure or hypertrophy. A significant correlation was found between the left atrial volume index and maximal aerobic capacity (R > 0.3; p < 0.001. Left atrial strain parameters were independent of atrial size, left ventricle hypertrophy and left ventricle filling pressure. Decreased peak atrial longitudinal strain was observed in 4 individuals (3.5%. We concluded that LA enlargement was common in healthy, young athletes participating in endurance sport disciplines with a high level of static exertion and was strictly correlated with exercise capacity, therefore, could be perceived as another sign of athlete’s heart.

  2. LEFT ATRIAL FIBROSIS IN PATIENTS WITH ATRIAL FIBRILLATION ACCORDING TO MAGNETIC RESONANCE IMAGING WITH LATE GADOLINIUM ENHANCEMENT

    Directory of Open Access Journals (Sweden)

    O. V. Stukalova

    2015-01-01

    Full Text Available Rationale: Atrial fibrillation (AF is the most common type of arrhythmia. Left atrial abnormalities in AF require further investigation.Aim: To evaluate characteristics of myocardial structure of the left atrium by magnetic resonance imaging (MRI with delayed contrast enhancement in patients with AF associated with essential hypertension (EH, in those without any cardiovascular disorders, and in patients with AF after cryoablation of the pulmonary artery orifice.Materials and methods: The study enrolled 53 patients with AF (mean age 56 years. Twenty eight of them had AF without any associated cardiovascular disorders (lone AF, or LAF group, 25 patients had AF related to EH (AF + EH group. Three patients had undergone anti-arrhythmic intervention. Cardiac MRI was performed in all patients with high resolution late gadolinium enhancement (LGE at 15–20 min after i.v. gadoversetamide (0.15 mmol/kg. For LGE MRI, we used a novel high resolution inversion recovery (inversion times 290–340 ms magnetic resonance pulse sequence with isotropic voxel (size 1.25 . 1.25 .2.5 mm and fat saturation. Left atrium walls were segmented semi-automatically on the LGE images. Left atrium fibrosis quantification was performed with the original software LGE Heart Analyzer, developed in Russian Cardiology Research and Production Complex (Moscow.Results: Left atrium fibrosis (mean, 9 [1.7; 18] % was found both in patients with AF + EH and with lone AF. There was a trend towards more significant left atrial fibrosis in the group of AF + EH, compared to that in the lone AF group (10.972 [6.98; 19.366] % vs 4.37 [0.893; 18.575] %, respectively, p = 0.1. The extent of left atrium fibrosis correlated with left atrium dilatation (r = 0.37, p < 0.001 and with the decreased ejection fraction (r = -0.4, р < 0.001. The patients who had undergone an antiarrhythmic intervention, demonstrated formation of intensive LGE zones in the ablation areas.Conclusion: Quantification of

  3. Magnetic resonance imaging and angiography of the brain in embolic left atrial myxoma

    International Nuclear Information System (INIS)

    Marazuela, M.; Yebra, M.; Diego, J.; Durantez, A.; Garcia-Merino, A.; Brasa, J.M.

    1989-01-01

    A case of left atrial myxoma presenting exclusively with neurological symptoms, studies with magnetic resonance imaging (MRI) combined with cerebral angiography and computed tomography (CT) is reported. Typical angiographic findings suggested the diagnosis of myxoma. MRI showed multiple ischemic lesions disseminated throughout the entire brain, some of which had been clinically asymptomatic. Because of its sensitivity in identifying small cerebral infarcts, MRI should prove in the future to be a first-choice technique in the evaluation of the presence of an extent of cerebral involvement in embolic left atrial myxoma. (orig.)

  4. Impact of congestive heart failure and left ventricular systolic function on the prognostic significance of atrial fibrillation and atrial flutter following acute myocardial infarction

    DEFF Research Database (Denmark)

    Pedersen, Ole Dyg; Bagger, Henning; Køber, Lars

    2005-01-01

    fibrillation in acute myocardial infarction patients that might explain previous discrepancies. METHODS: The study population was 6676 patients consecutively admitted to hospital with acute myocardial infarction. Information on the presence of atrial fibrillation/flutter, left ventricular systolic function......BACKGROUND: Reports on the prognostic importance of atrial fibrillation following myocardial infarction have provided considerable variation in results. Thus, this study examined the impact of left ventricular systolic function and congestive heart failure on the prognostic importance of atrial...... and congestive heart failure were prospectively collected. Mortality was followed for 5 years. RESULTS: In patients with left ventricular ejection fraction

  5. LEFT ATRIAL APPENDAGE CLOSURE AS AN ALTERNATIVE TO WARFARIN FOR STROKE PREVENTION IN ATRIAL FIBRILLATION: A PATIENT¬LEVEL META¬ANALYSIS

    Directory of Open Access Journals (Sweden)

    2015-01-01

    Full Text Available Holmes D.R. Jr, Doshi S.K., Kar S., et al. Left Atrial Appendage Closure as an Alternative to Warfarin for Stroke Prevention in Atrial Fibrillation: A Patient­Level Meta­Analysis // J. Am. Coll. Cardiol. – 2015. – Vol. 65. – P. 2614–2623.

  6. Ticagrelor, but not clopidogrel active metabolite, displays antithrombotic properties in the left atrial endocardium.

    Science.gov (United States)

    Reiner, Martin F; Breitenstein, Alexander; Holy, Erik W; Glanzmann, Martina; Amstalden, Heidi; Stämpfli, Simon F; Bonetti, Nicole R; Falk, Volkmar; Keller, Stephan; Savarese, Gianluigi; Benussi, Stefano; Maisano, Francesco; Lüscher, Thomas F; Beer, Jürg H; Steffel, Jan; Camici, Giovanni G

    2017-03-21

    Oral anticoagulation is considered standard therapy for stroke prevention in atrial fibrillation (AF). Endocardial activation triggers expression of pro-thrombotic mediators including tissue factor (TF) and plasminogen activator inhibitor-1 (PAI-1), and contributes to thrombus formation in the left atrial appendage (LAA) of AF patients. Recently, pleiotropic effects of specific P2Y12 receptor antagonists were demonstrated; however, whether these drugs possess antithrombotic effects on LAA endocardial cells currently remains unknown. LAA were obtained from 14 patients with known AF undergoing elective cardiac surgery including LAA removal at the University Hospital Zurich. LAA endocardial cells were isolated and pre-incubated with ticagrelor (10-7, 10-6, 10-5M) or clopidogrel active metabolite (CAM) (1.5 × 10-8, 1.5 × 10-7, 1.5 × 10-6 M) before stimulation with tumour necrosis factor-alpha (TNF-α) (10 ng/mL). Finally, TF and PAI-1 expression and activity were analysed. Ticagrelor, unlike CAM, concentration dependently decreased TNF-α-induced TF expression and TF activity in LAA endocardial cells. Further, ticagrelor, but not CAM reduced PAI-1 expression and enzyme activity in TNF-α-stimulated LAA endocardial cells. In contrast, TF pathway inhibitor (TFPI) remained unaffected by both dugs. Ticagrelor, but not CAM, reduces expression and activity of TF and PAI-1 in LAA endocardial cells isolated from patients with AF, indicating possible local antithrombotic effects. Such pleiotropic properties of ticagrelor may contribute to a reduction in thromboembolic complications in patients with AF. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  7. Assessments of pulmonary vein and left atrial anatomical variants in atrial fibrillation patients for catheter ablation with cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Jing; Yang, Zhi-Gang; Xu, Hua-Yan; Shi, Ke; Long, Qi-Hua [Sichuan University, Department of Radiology, West China Hospital, Chengdu, Sichuan (China); Guo, Ying-Kun [Sichuan University, Department of Radiology, West China Second University Hospital, Chengdu (China)

    2017-02-15

    To provide a road map of pulmonary vein (PV) and left atrial (LA) variants in patients with atrial fibrillation (AF) before catheter ablation procedure using cardiac CT. Cardiac CT was performed in 1420 subjects for accurate anatomical information, including 710 patients with AF and 710 matched controls without AF. PV variants, PV ostia and spatial orientation, LA enlargement, and left atrial diverticulum (LAD) were measured, respectively. Differences between these two groups were also respectively compared. Some risk factors for the occurrence of LAD were analyzed. In total, PV variants were observed in 202 (28.5 %) patients with AF patients and 206 (29.0 %) controls without AF (p = 0.8153). The ostial sizes of all accessory veins were generally smaller than those of the typical four PVs (p = 0.0153 to 0.3958). There was a significant difference of LA enlargement between the AF and control groups (36.3 % vs. 12.5 %, p < 0.0001), while the prevalence of LAD was similar in these two groups (43.2 % vs. 41.9 %, p = 0.6293). PV variants are common. Detailed knowledge of PVs and LA variants are helpful for providing anatomical road map to determine ablation strategy. (orig.)

  8. Assessments of pulmonary vein and left atrial anatomical variants in atrial fibrillation patients for catheter ablation with cardiac CT

    International Nuclear Information System (INIS)

    Chen, Jing; Yang, Zhi-Gang; Xu, Hua-Yan; Shi, Ke; Long, Qi-Hua; Guo, Ying-Kun

    2017-01-01

    To provide a road map of pulmonary vein (PV) and left atrial (LA) variants in patients with atrial fibrillation (AF) before catheter ablation procedure using cardiac CT. Cardiac CT was performed in 1420 subjects for accurate anatomical information, including 710 patients with AF and 710 matched controls without AF. PV variants, PV ostia and spatial orientation, LA enlargement, and left atrial diverticulum (LAD) were measured, respectively. Differences between these two groups were also respectively compared. Some risk factors for the occurrence of LAD were analyzed. In total, PV variants were observed in 202 (28.5 %) patients with AF patients and 206 (29.0 %) controls without AF (p = 0.8153). The ostial sizes of all accessory veins were generally smaller than those of the typical four PVs (p = 0.0153 to 0.3958). There was a significant difference of LA enlargement between the AF and control groups (36.3 % vs. 12.5 %, p < 0.0001), while the prevalence of LAD was similar in these two groups (43.2 % vs. 41.9 %, p = 0.6293). PV variants are common. Detailed knowledge of PVs and LA variants are helpful for providing anatomical road map to determine ablation strategy. (orig.)

  9. The left atrio-vertebral ratio. A new simple means for assessing left atrial enlargement on computed tomography

    International Nuclear Information System (INIS)

    Montillet, Marie; Tasu, Jean-Pierre; Baque-Juston, Marie; Bertrand, Sandra; Berthier, Frederic; Zarqane, Naima; Brunner, Philippe

    2018-01-01

    The purpose of this study is to describe a new method to quickly estimate left atrial enlargement (LAE) on Computed Tomography. Left atrial (LA) volume was assessed with a 3D-threshold Hounsfield unit detection technique, including left atrial appendage and excluding pulmonary venous confluence, in 201 patients with ECG-gated 128-slice dual-source CT and indexed to body surface area. LA and vertebral axial diameter and area were measured at the bottom level of the right inferior pulmonary vein ostium. Ratio of LA diameter and surface on vertebra (LAVD and LAVA) were compared to LA volume. In accordance with the literature, a cutoff value of 78 ml/m 2 was chosen for maximal normal LA volume. 18% of LA was enlarged. The best cutoff values for LAE assessment were 2.5 for LAVD (AUC: 0.65; 95% CI: 0.58-0.73; sensitivity: 57%; specificity: 71%), and 3 for LAVA (AUC: 0.78; 95% CI: 0.72-0.84; sensitivity: 67%; specificity: 79%), with higher accuracy for LAVA (P=0.015). Inter-observer and intra-observer variability were either good or excellent for LAVD and LAVA (respective intraclass coefficients: 0.792 and 0.910; 0.912 and 0.937). A left atrium area superior to three times the vertebral area indicates LAE with high specificity. (orig.)

  10. The left atrio-vertebral ratio. A new simple means for assessing left atrial enlargement on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Montillet, Marie; Tasu, Jean-Pierre [Centre Hospitalier Universitaire de Poitiers, Poitiers (France); Baque-Juston, Marie; Bertrand, Sandra; Berthier, Frederic; Zarqane, Naima; Brunner, Philippe [Hopital Princesse Grace, Monaco (Monaco)

    2018-03-15

    The purpose of this study is to describe a new method to quickly estimate left atrial enlargement (LAE) on Computed Tomography. Left atrial (LA) volume was assessed with a 3D-threshold Hounsfield unit detection technique, including left atrial appendage and excluding pulmonary venous confluence, in 201 patients with ECG-gated 128-slice dual-source CT and indexed to body surface area. LA and vertebral axial diameter and area were measured at the bottom level of the right inferior pulmonary vein ostium. Ratio of LA diameter and surface on vertebra (LAVD and LAVA) were compared to LA volume. In accordance with the literature, a cutoff value of 78 ml/m{sup 2} was chosen for maximal normal LA volume. 18% of LA was enlarged. The best cutoff values for LAE assessment were 2.5 for LAVD (AUC: 0.65; 95% CI: 0.58-0.73; sensitivity: 57%; specificity: 71%), and 3 for LAVA (AUC: 0.78; 95% CI: 0.72-0.84; sensitivity: 67%; specificity: 79%), with higher accuracy for LAVA (P=0.015). Inter-observer and intra-observer variability were either good or excellent for LAVD and LAVA (respective intraclass coefficients: 0.792 and 0.910; 0.912 and 0.937). A left atrium area superior to three times the vertebral area indicates LAE with high specificity. (orig.)

  11. Left atrial function to identify patients with atrial fibrillation at high risk of stroke: new insights from a large registry.

    Science.gov (United States)

    Leung, Melissa; van Rosendael, Philippe J; Abou, Rachid; Ajmone Marsan, Nina; Leung, Dominic Y; Delgado, Victoria; Bax, Jeroen J

    2018-04-21

    Atrial fibrillation (AF) is an independent risk factor for ischaemic stroke. The CHA2DS2-VASc is the most widely used risk stratification model; however, echocardiographic refinement may be useful, particularly in low risk AF patients. The present study examined the association between advanced echocardiographic parameters and ischaemic stroke, independent of CHA2DS2-VASc score. One thousand, three hundred and sixty-one patients (mean age 65±12 years, 74% males) with first diagnosis of AF and baseline transthoracic echocardiogram were followed by chart review for the occurrence of stroke over a mean of 7.9 years. Left atrial (LA) volumes, LA reservoir strain, P-wave to A' duration on tissue Doppler imaging (PA-TDI, reflecting total atrial conduction time), and left ventricular (LV) global longitudinal strain (GLS) were evaluated in patients with and without stroke. The independent association of these echocardiographic parameters with the occurrence of ischaemic stroke was evaluated with Cox proportional hazard models. One-hundred patients (7%) developed an ischaemic stroke, representing an annualized stroke rate of 0.9%. The incident stroke rate in the year following the first diagnosis of AF was 2.6% in the entire population and higher than the remainder of the follow-up period. Left atrial reservoir (14.5% vs. 18.9%, P = 0.005) and conduit strains were reduced (10.5% vs. 13.5%, P = 0.013), and PA-TDI lengthened (166 ms vs. 141 ms, P Left atrial reservoir strain and PA-TDI were independently associated with risk of stroke in a model including CHA2DS2-VASc score, age, and anticoagulant use. The assessment of LA reservoir strain and PA-TDI on echocardiography after initial CHA2DS2-VASc scoring provides additional risk stratification for stroke and may be useful to guide decisions regarding anticoagulation for patients upon first diagnosis of AF.

  12. Percutaneous left atrial appendage occlusion for stroke prevention in atrial fibrillation

    DEFF Research Database (Denmark)

    De Backer, O; Arnous, S; Ihlemann, N

    2014-01-01

    Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia encountered in clinical practice. One of its most devastating complications is the development of thromboembolism leading to fatal or disabling stroke. Oral anticoagulation (OAC, warfarin) is the standard treatment for strok...

  13. Use of computed tomography to identify atrial fibrillation associated differences in left atrial wall thickness and density.

    Science.gov (United States)

    Dewland, Thomas A; Wintermark, Max; Vaysman, Anna; Smith, Lisa M; Tong, Elizabeth; Vittinghoff, Eric; Marcus, Gregory M

    2013-01-01

    Left atrial (LA) tissue characteristics may play an important role in atrial fibrillation (AF) induction and perpetuation. Although frequently used in clinical practice, computed tomography (CT) has not been employed to describe differences in LA wall properties between AF patients and controls. We sought to noninvasively characterize AF-associated differences in LA tissue using CT. CT images of the LA were obtained in 98 consecutive patients undergoing AF ablation and in 89 controls. A custom software algorithm was used to measure wall thickness and density in four prespecified regions of the LA. On average, LA walls were thinner (-15.5%, 95% confidence interval [CI] -23.2 to -7.8%, P identified significant thinning of the LA wall and regional alterations in tissue density in patients with a history of AF. These findings suggest differences in LA tissue composition can be noninvasively identified and quantified using CT. ©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.

  14. Left atrial appendage thrombus with resulting stroke post-RF ablation for atrial fibrillation in a patient on dabigatran.

    LENUS (Irish Health Repository)

    Lobo, R

    2015-11-01

    Dabigatran etexilate is licensed for use in prevention of deep venous thromboembolism and in prevention of stroke and systemic embolism in nonvalvular atrial fibrillation (AF). It has also been used in patients for other indications as a substitute for warfarin therapy because it requires no monitoring; one group being patients undergoing radiofrequency (RF), ablation for AF, although there have been no consensus guidelines with regards to dosage and timing of dose. We report the case of a patient with documentary evidence of left atrial appendage (LAA) thrombus formation and neurological sequelae post-RF ablation despite being on dabigatran. This case highlights the concern that periprocedural dabigatran may not provide adequate protection from development of LAA thrombus and that a standardised protocol will need to be developed and undergo large multicentre trials before dabigatran can be safely used for patients undergoing RF-ablation.

  15. Cost-effectiveness analysis of left atrial appendage occlusion compared with pharmacological strategies for stroke prevention in atrial fibrillation.

    Science.gov (United States)

    Lee, Vivian Wing-Yan; Tsai, Ronald Bing-Ching; Chow, Ines Hang-Iao; Yan, Bryan Ping-Yen; Kaya, Mehmet Gungor; Park, Jai-Wun; Lam, Yat-Yin

    2016-08-31

    Transcatheter left atrial appendage occlusion (LAAO) is a promising therapy for stroke prophylaxis in non-valvular atrial fibrillation (NVAF) but its cost-effectiveness remains understudied. This study evaluated the cost-effectiveness of LAAO for stroke prophylaxis in NVAF. A Markov decision analytic model was used to compare the cost-effectiveness of LAAO with 7 pharmacological strategies: aspirin alone, clopidogrel plus aspirin, warfarin, dabigatran 110 mg, dabigatran 150 mg, apixaban, and rivaroxaban. Outcome measures included quality-adjusted life years (QALYs), lifetime costs and incremental cost-effectiveness ratios (ICERs). Base-case data were derived from ACTIVE, RE-LY, ARISTOTLE, ROCKET-AF, PROTECT-AF and PREVAIL trials. One-way sensitivity analysis varied by CHADS2 score, HAS-BLED score, time horizons, and LAAO costs; and probabilistic sensitivity analysis using 10,000 Monte Carlo simulations was conducted to assess parameter uncertainty. LAAO was considered cost-effective compared with aspirin, clopidogrel plus aspirin, and warfarin, with ICER of US$5,115, $2,447, and $6,298 per QALY gained, respectively. LAAO was dominant (i.e. less costly but more effective) compared to other strategies. Sensitivity analysis demonstrated favorable ICERs of LAAO against other strategies in varied CHADS2 score, HAS-BLED score, time horizons (5 to 15 years) and LAAO costs. LAAO was cost-effective in 86.24 % of 10,000 simulations using a threshold of US$50,000/QALY. Transcatheter LAAO is cost-effective for prevention of stroke in NVAF compared with 7 pharmacological strategies. The transcatheter left atrial appendage occlusion (LAAO) is considered cost-effective against the standard 7 oral pharmacological strategies including acetylsalicylic acid (ASA) alone, clopidogrel plus ASA, warfarin, dabigatran 110 mg, dabigatran 150 mg, apixaban, and rivaroxaban for stroke prophylaxis in non-valvular atrial fibrillation management.

  16. LEFT-VENTRICULAR BEAT-TO-BEAT PERFORMANCE IN ATRIAL-FIBRILLATION - CONTRIBUTION OF FRANK-STARLING MECHANISM AFTER SHORT RATHER THAN LONG RR INTERVALS

    NARCIS (Netherlands)

    GOSSELINK, ATM; BLANKSMA, PK; CRIJNS, HJGM; VANGELDER, IC; DEKAM, PJ; HILLEGE, HL; NIEMEIJER, MG; LIE, KI; MEIJLER, FL

    1995-01-01

    Objectives. This study sought to evaluate control mechanisms of the varying left ventricular performance in atrial fibrillation. Background. Atrial fibrillation is characterized by a randomly irregular ventricular response, resulting in continuous variation in left ventricular beat-to-beat

  17. Left ventricular beat-to-beat performance in atrial fibrillation: Contribution of Frank-Starling mechanism after short rather than long intervals

    NARCIS (Netherlands)

    Gosselink, A.T.M.; Blanksma, P.K.; Crijns, H.J.G.M.; Gelder, I.C. van; Kam, P.J. de; Hillege, H.L.; Niemeijer, M.G.; Lie, K.I.; Meijler, F.L.

    1995-01-01

    This study sought to evaluate control mechanisms of the varying left ventricular performance in atrial fibrillation. Atrial fibrillation is characterized by a randomly irregular ventricular response, resulting in continuous variation in left ventricular beat-to-beat mechanical behavior and

  18. Epidemiological study of dilated cardiomyopathy from eastern India with special reference to left atrial size

    Directory of Open Access Journals (Sweden)

    Rudrajit Paul, Saumen Nandi, Pradip K Sinha

    2014-07-01

    Full Text Available Dilated cardiomyopathy (DCM is a common cause of emergency visit in our country. The disease is often misdiagnosed and mistreated. There are very few studies on DCM from India. We undertook a small study on DCM patients from Eastern India to find the demographic and echocardiographic characteristics. Patients and methods: We under took this study in a tertiary care Medical College of Eastern India. All patients coming to the emergency with dyspnea were evaluated for cardiac dysfunction. Emergency echocardiography was done to diagnose dilated cardiomyopathy. Patients with DCM were then evaluated as per protocol. After stabilization, echocardiography was repeated to note the study parameters like left atrial diameter. Standard statistical tests were used. Results: we had a total of 70 patients in our study with a male: female ratio of 43:27. Most patients were aged over 40 years. Patients with COPD, history of radiation, malignancy or drug abuse were excluded. Most patients (47% were on NYHA stage 3 at the time of presentation. In our patient cohort, 24% were alcoholic and 46% were smokers. Atrial fibrillation was present in 15.7% of the patients and right and left bundle branch block had been present in 8 and 15 patients respectively. In echocardiography, increased left atrial (LA size (>40 mm was found in 45 patients. Many patients had valvular regurgitation, mitral, aortic or tricuspid. LA size was positively correlated with left ventricular systolic diameter (r=0.403 and negatively correlated with ejection fraction (r= -0.23. Analysis and conclusion: different ECG abnormalities like bundle branch block and arrhythmias like atrial fibrillation are quite common in DCM. In echocardiography, left atrial size is an important prognostic marker and correlates with left ventricular function.

  19. Cine MR imaging in mitral valve prolapse; Study on mitral regurgitation and left atrial volume

    Energy Technology Data Exchange (ETDEWEB)

    Kumai, Toshihiko [Chiba Univ. (Japan). School of Medicine

    1993-02-01

    This study was undertaken to assess the ability of cine MR imaging to evaluate the direction, timing, and severity of mitral regurgitation in patients with mitral valve prolapse (MVP). The population of this study was 33 patients with MVP diagnosed by two-dimensional echocardiography and 10 patients with rheumatic mitral valve disease (MSR) for comparison. 7 patients with MVP and 5 with MSR had atrial fibrillation and/or history of congestive heart failure as complications. Mitral regurgitation was graded for severity by color Doppler flow imaging in all patients. Direction and size of systolic flow void in the left atrium were analyzed by contiguous multilevel cine MR images and the maximum volumes of flow void and left atrium were measured. Although flow void was found at the center of the left atrium in most of MSR, it was often directed along the postero-caudal atrial wall in anterior leaflet prolapse and along the anterocranial atrial wall in posterior leaflet prolapse. In MVP, the maximum volume of flow void was often seen in late systole. The maximum volume of flow void and that of left atrium were significantly larger in patients with atrial fibrillation and/or history of congestive heart failure. The length and volume of flow void were increased with clinical severity and degree of regurgitation determined by color Doppler flow imaging. Thus cine MR imaging provides a useful means for detection and semiquantitative evaluation of mitral regurgitation in subjects with MVP. (author).

  20. Predictors and prognostic value of left atrial remodelling after acute myocardial infarction

    DEFF Research Database (Denmark)

    Kyhl, Kasper; Vejlstrup, Niels; Lønborg, Jacob

    2015-01-01

    PURPOSE: Left atrial (LA) volume is a strong prognostic predictor in patients following ST-segment elevation myocardial infarction (STEMI). However, the change in LA volume over time (LA remodelling) following STEMI has been scarcely studied. We sought to identify predictors for LA remodelling an...

  1. Left atrial and left ventricular diastolic function after the maze procedure for atrial fibrillation in mitral valve disease: degenerative versus rheumatic.

    Science.gov (United States)

    Kim, Hwan Wook; Moon, Mi Hyoung; Jo, Keon Hyun; Song, Hyun; Lee, Jae Won

    2015-02-01

    The present study was aimed to compare the left atrial and left ventricular diastolic functions amongst the rheumatic and degenerative mitral valve disease patients in atrial fibrillation who reverted to normal sinus rhythm following Cox-maze procedure. We prospectively investigated the left atrial and left ventricular function with Doppler echocardiography, by dividing into the rheumatic (N = 105) and the degenerative group (N = 47). Over the follow-up period (mean: 4.4 ± 1.2 years in the rheumatic group, 4.8 ± 1.3 years in the degenerative group), the rheumatic group showed statistically significant decrease in A' velocity and E' velocity, on contrary to degenerative group (A' velocity: mean decrease of 0.43 ± 0.13 cm/s in the rheumatic group, mean increase of 0.57 ± 0.11 cm/s in the degenerative group, p = 0.029, E' velocity: mean decrease of 0.23 ± 0.17 cm/s in the rheumatic group, mean increase of 0.21 ± 0.15 cm/s in the degenerative group, p = 0.031). In addition, the rheumatic group showed statistically significant increase in E/E' ratio than the degenerative group (mean increase of 4.49 ± 1.98 in the rheumatic group, mean increase of 1.74 ± 1.52 in the degenerative group, p = 0.047). Despite successful sinus rhythm restoration, the progressive loss of LA function as well as LV diastolic function is more prominent in the rheumatic group than the degenerative group. Therefore, differentiated strategies for postoperative surveillance are needed according to the pathology of mitral valve disease.

  2. Characteristics of complex fractionated atrial electrogram in the electroanatomically remodeled left atrium of patients with atrial fibrillation

    International Nuclear Information System (INIS)

    Park, Jae-Hyung; Kim, Jong-Youn; Park, Sang-Weon

    2010-01-01

    Complex fractionated atrial electrogram (CFAE) guided ablation is effective in some patients with persistent atrial fibrillation (PeAF), but the pattern of CFAE may be different in the remodeled left atrium (LA). In 100 AF patients (83 males, 55.0±10.6 years old) with AF (51 paroxysmal AF (PAF), 49 PeAF) who underwent catheter ablation, CFAE cycle length (CL) and distribution (NavX 3D map) were compared according to the LA volume (3D-CT) and endocardial voltage (during high right atrial pacing 500-ms (Vol PACE ) and AF (Vol AF ; NavX). The mean CFAE-CL was longer (P=0.003) and the % area CFAE was smaller (P=0.006) in patients with LA ≥125 ml than those with PACE AF PACE <1.7 mV than those with ≥1.7 mV (P=0.006). The incidence of septal CFAE was consistently high, regardless of the degree of LA remodeling. In the AF patients with an electroanatomically remodeled LA, the % area of CFAE was smaller and mean CFAE-CL was longer than in those with a less remodeled LA. However, the majority of CFAE are consistently positioned on the septum in the remodeled LA. (author)

  3. A case of anemia with left atrial myxoma suspected as late effect of an atomic bomb

    International Nuclear Information System (INIS)

    Sugahara, Hiroko; Aosaki, Noboru; Kurita, Akira

    1980-01-01

    A 43 years old housewife with a history of exposure to an atomic bomb at 8 years old, recently developed anemia and palpitation. The laboratory data showed accelerated ESR, anemia (Hb 10.0 g/dl), and hyper γ-globulinemia. Despite the suspicion of late effect of atomic radiation, further examinations confirmed the diagnosis of left atrial myxoma. The echocardiographic studies revealed the decrease of diastolic descent rate, and multiple echos reflected from the tumor within the mitral orifice during diastole. Cardiac catheterization demonstrated remarkably high value of PCWP (V-wave 38 mmHg) and space filling defect moving from left atrium to left ventricle by cineangiography. Phonecardiographic studies were similar to mitral stenosis. After left atrial myxoma was removed, her symptoms and laboratory data including all noninvasive findings were improved. Therefore we suspected that her symptoms was related with left atrial myxoma rather than the late effect of atomic bomb exposure. We have discussed its significance and usefulness of noninvasive diagnostic approaches as well as whole body computed tomography in heart tumor. (author)

  4. Ventricular, but not atrial, M2-muscarinic receptors increase in the canine pacing-overdrive model of heart failure.

    Science.gov (United States)

    Wilkinson, M; Giles, A; Armour, J A; Cardinal, R

    1996-01-01

    To investigate the effects of heart failure induced by chronic rapid ventricular pacing (six weeks) on canine atrial and ventricular muscarinic receptors. Dogs (n = 4) were fitted with a bipolar pacing electrode connected to a Medtronic pacemaker set at 240 stimuli/min. Pacing was maintained for six weeks. Tissue samples obtained from the left atrium and ventral wall of the left ventricle were frozen at -70 degrees C. Control tissue was obtained from normal dogs (n = 6) following anesthesia and thoracotomy. M2-muscarinic receptors were characterized and quantified in tissue micropunches using the hydrophilic ligand [3H] N-methyl-scopolamine (NMS). Cardiac tissue bound [3H] NMS with the specificity of an M2 subtype. Tachycardia-induced heart failure did not affect atrial muscarinic receptors but signify left ventricular myocytes (control 160.0 +/- 10.0 fmol/mg protein versus heart failure 245.0 +/- 25.0 fmol/mg protein; P failure was accompanied by an increase (+ 53%) in ventricular, but not atrial, M2 receptors compared with normal dogs.

  5. The incidence and characteristics of supraventricular tachycardia in left atrial isomerism: a high incidence of atrial fibrillation in young patients.

    Science.gov (United States)

    Miyazaki, Aya; Sakaguchi, Heima; Ohuchi, Hideo; Yamamoto, Tetsuya; Igarashi, Takehiro; Negishi, Jun; Toyota, Naoki; Kagisaki, Koji; Yagihara, Toshikatsu; Yamada, Osamu

    2013-06-20

    In left atrial isomerism (LAI), both atria show left atrial morphology. Although bradyarrhythmias are frequent and highly complex in LAI patients, previous studies have reported a low incidence of supraventricular tachycardia (SVT). To evaluate the incidence and characteristics of SVT in LAI, we retrospectively evaluated the clinical characteristics of SVTs in 83 patients with LAI (age at last follow-up, 15.3±10.5 years). There were 27 SVTs in 19 patients (23%), including nine episodes of atrial fibrillation (AF) and eight non-reentrant SVTs. Sixteen of the 19 patients with SVT had histories of atriotomy, but the three patients with AF or non-reentrant tachycardia had no history of atriotomy. The rates of freedom from SVT were 66% and 59% at ages of 20 and 30 years, respectively; the corresponding rates for freedom from AF were 89% and 74%. In multivariate analysis, the predictors of SVT were age (OR, 1.14; 95% CI, 1.06-1.26; p=0.003) and sinus node dysfunction (SND) (OR, 3.88; 95% CI, 1.57-13.34; p=0.01). In patients with LAI, SVTs are common, and AF and non-reentrant SVTs are the major type of SVTs. The incidence of AF was high in young patients with LAI. The lack of anatomical barriers in the atria that allow the formation of macro-reentrant circuits may account for the higher incidence of AF and non-reentrant SVT than macro-reentrant tachycardia. Moreover, the increasing prevalence of SND with age should contribute to a higher incidence of SVT. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  6. Evaluation of left atrial function by multidetector computed tomography before left atrial radiofrequency-catheter ablation: Comparison of a manual and automated 3D volume segmentation method

    International Nuclear Information System (INIS)

    Wolf, Florian; Ourednicek, Petr; Loewe, Christian; Richter, Bernhard; Goessinger, Heinz David; Gwechenberger, Marianne; Plank, Christina; Schernthaner, Ruediger Egbert; Toepker, Michael; Lammer, Johannes; Feuchtner, Gudrun M.

    2010-01-01

    Introduction: The purpose of this study was to compare a manual and automated 3D volume segmentation tool for evaluation of left atrial (LA) function by 64-slice multidetector-CT (MDCT). Methods and materials: In 33 patients with paroxysmal atrial fibrillation a MDCT scan was performed before radiofrequency-catheter ablation. Atrial function (minimal volume (LAmin), maximal volume (LAmax), stroke volume (SV), ejection fraction (EF)) was evaluated by two readers using a manual and an automatic tool and measurement time was evaluated. Results: Automated LA volume segmentation failed in one patient due to low LA enhancement (103HU). Mean LAmax, LAmin, SV and EF were 127.7 ml, 93 ml, 34.7 ml, 27.1% by the automated, and 122.7 ml, 89.9 ml, 32.8 ml, 26.3% by the manual method with no significant difference (p > 0.05) and high Pearsons correlation coefficients (r = 0.94, r = 0.94, r = 0.82 and r = 0.85, p < 0.0001), respectively. The automated method was significantly faster (p < 0.001). Interobserver variability was low for both methods with Pearson's correlation coefficients between 0.98 and 0.99 (p < 0.0001). Conclusions: Evaluation of LA volume and function with 64-slice MDCT is feasible with a very low interobserver variability. The automatic method is as accurate as the manual method but significantly less time consuming permitting a routine use in clinical practice before RF-catheter ablation.

  7. In-treatment reduced left atrial diameter during antihypertensive treatment is associated with reduced new-onset atrial fibrillation in hypertensive patients with left ventricular hypertrophy: The LIFE Study

    DEFF Research Database (Denmark)

    Wachtell, Kristian; Gerdts, Eva; Aurigemma, Gerard P

    2010-01-01

    It is unclear whether improvement of left atrial (LA) and ventricular (LV) structure results in reduction in new-onset atrial fibrillation (AF). The aim of the present study was to examine whether changes in-treatment LA diameter were related to changes in risk of new-onset AF....

  8. Prevention of Cerebral Embolism Progression by Emergency Surgery of the Left Atrial Myxoma

    Directory of Open Access Journals (Sweden)

    Syuichi Tetsuka

    2015-01-01

    Full Text Available A 21-year-old woman developed left hemiparesis during work and was hospitalized. Her National Institutes of Health Stroke Scale score was 4. Hyperintense areas in the left basal ganglia, corona radiata, and cortex of the temporal lobe were found by brain diffusion-weighted magnetic resonance imaging, indicating acute cerebral infarction. Echocardiography showed a giant mass of diameter 7 × 4 cm in the left atrium. Therefore, she was diagnosed with cerebral embolism due to a left atrial myxoma. Currently, thrombolytic therapy may continue to be effective because the embolic source may be composed of tumor tissue itself. In case of atrial myxoma, we considered that the use of tPA as emergency treatment in all patients with infarction by atrial myxoma may be questioned. Thus, cardiac tumor extraction was performed the next day after hospitalization without thrombolytic therapy. The excised myxoma measured 7 × 6 × 4 cm. The patient recovered and her neurological symptoms also improved. Furthermore, her National Institutes of Health Stroke Scale score improved to 0. Thirteen days after admission, the patient was discharged from our hospital. Cardiac myxoma is often associated with a high risk of embolic episodes, which emphasizes the need for prompt surgical excision as soon as the diagnosis is confirmed.

  9. Right and Left Ventricular Volumes in Atrial Septal Defect Studied by Radiocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Ivancevic, D. [Radioisotope Department, Internal Clinic, Rebro, Zagreb, Yugoslavia (Croatia); Vernejoul, P. de; Kellershohn, C. [CEA, Service Hospitalier Frederic Joliot, Departement de Biologie, Orsay (France)

    1971-02-15

    Radiocardiography with radioiodinated ({sup 131}I) human serum albumin and barium ({sup 137m}Ba) solution injected into the right subclavian vein has been performed in a group of 43 patients with atrial septal defect and left-to-right shunt. Data on the output and ejection index of each ventricle are essential for the estimation of the diastolic and residual volumes of the right and left ventricle. The systemic flow was therefore calculated according to Veall's formula and the pulmonary flow and the shunt How were determined using the method of de Vernejoul and co-workers. The formulas for the calculation of ventricular volumes were modified. The results show that many cases of atrial septal defect have an enlarged right ventricle whereas the left ventricle remains normal or is diminished. These changes correlate well with the amount of the shunt flow. In both ventricles the ventricular volumes show a good correlation with the stroke volumes. For the regulation of the pulmonary blood volume the right ventricle seems to be more important than the left ventricle. The operative closure of atrial septal defect (in 14 patients) has normalized the size of ventricular volumes. (author)

  10. Late thrombosis of a mitral bioprosthetic valve with associated massive left atrial thrombus

    Directory of Open Access Journals (Sweden)

    Preetham R Muskula

    2017-04-01

    Full Text Available An 84-year-old man presented 5 years after bioprosthetic mitral valve replacement with three months of worsening dyspnea on exertion. A new mitral stenosis murmur was noted on physical examination, and an electrocardiogram revealed newly recognized atrial fibrillation. Severe mitral stenosis (mean gradient = 13 mmHg was confirmed by transthoracic echocardiography. Transesophageal echocardiography revealed markedly thickened mitral bioprosthetic leaflets with limited mobility, and a massive left atrial thrombus (>4 cm in diameter (Fig. 1A, B, C, D and Videos 1, 2, 3 and 4. Intravenous heparin was initiated, and 5 days later, he was taken to the operating room for planned redo mitral valve replacement and left atrial thrombus extraction. Intraoperative transesophageal echocardiography revealed near-complete resolution of the bioprosthetic leaflet thickening, and a mean mitral gradient of only 3 mmHg (Fig. 2A, B, C and Videos 5, 6 and 7. The patient underwent resection of the massive left atrial thrombus (Fig. 2D but did not require redo mitral valve replacement. He was initiated on heparin (and transitioned to warfarin early in the post-operative period, with complete resolution of dyspnea on exertion at 3-month follow-up. Bioprosthetic valve thrombosis is increasingly recognized as a cause of early prosthetic valve dysfunction (1, 2. This case illustrates that bioprosthetic valve thrombosis may occur years after valve replacement; therefore, any deterioration in a patient’s clinical status (new-onset dyspnea, heart failure or atrial fibrillation warrants a thorough evaluation of the bioprosthetic valve with transesophageal echocardiography. In this case, initiation of anticoagulation obviated the need for redo mitral valve replacement.

  11. Left atrial leiomyosarcoma as cause of heart failure

    International Nuclear Information System (INIS)

    Valdes Martin, Alexander

    2012-01-01

    The case of a 26 year-old patient with diagnosis of heart failure and presence of a mobile echogenic mass without calcification attached to the posterolateral area of the left atrium was reported. She underwent surgery and tissue examination evidenced a high-grade heart leiomyosarcoma. Postoperative course was satisfactory and her clinical state was rigorously monitored by oncology and heart specialists in the institution

  12. Association Between Local Bipolar Voltage and Conduction Gap Along the Left Atrial Linear Ablation Lesion in Patients With Atrial Fibrillation.

    Science.gov (United States)

    Masuda, Masaharu; Fujita, Masashi; Iida, Osamu; Okamoto, Shin; Ishihara, Takayuki; Nanto, Kiyonori; Kanda, Takashi; Sunaga, Akihiro; Tsujimura, Takuya; Matsuda, Yasuhiro; Mano, Toshiaki

    2017-08-01

    A bipolar voltage reflects a thick musculature where formation of a transmural lesion may be hard to achieve. The purpose of this study was to explore the association between local bipolar voltage and conduction gap in patients with persistent atrial fibrillation (AF) who underwent atrial roof or septal linear ablation. This prospective observational study included 42 and 36 consecutive patients with persistent AF who underwent roof or septal linear ablations, respectively. After pulmonary vein isolation, left atrial linear ablations were performed, and conduction gap sites were identified and ablated after first-touch radiofrequency application. Conduction gap(s) after the first-touch roof and septal linear ablation were observed in 13 (32%) and 19 patients (53%), respectively. Roof and septal area voltages were higher in patients with conduction gap(s) than in those without (roof, 1.23 ± 0.77 vs 0.73 ± 0.42 mV, p = 0.010; septal, 0.96 ± 0.43 vs 0.54 ± 0.18 mV, p = 0.001). Trisected regional analyses revealed that the voltage was higher at the region with a conduction gap than at the region without. Complete conduction block across the roof and septal lines was not achieved in 3 (7%) and 6 patients (17%), respectively. Patients in whom a linear conduction block could not be achieved demonstrated higher ablation area voltage than those with a successful conduction block (roof, 1.91 ± 0.74 vs 0.81 ± 0.51 mV, p = 0.001; septal, 1.15 ± 0.56 vs 0.69 ± 0.31 mV, p = 0.006). In conclusion, a high regional bipolar voltage predicts failure to achieve conduction block after left atrial roof or septal linear ablation. In addition, the conduction gap was located at the preserved voltage area. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. The effect of activation rate on left atrial bipolar voltage in patients with paroxysmal atrial fibrillation.

    Science.gov (United States)

    Williams, Steven E; Linton, Nick; O'Neill, Louisa; Harrison, James; Whitaker, John; Mukherjee, Rahul; Rinaldi, Christopher A; Gill, Jaswinder; Niederer, Steven; Wright, Matthew; O'Neill, Mark

    2017-09-01

    Bipolar voltage is used during electroanatomic mapping to define abnormal myocardium, but the effect of activation rate on bipolar voltage is not known. We hypothesized that bipolar voltage may change in response to activation rate. By examining corresponding unipolar signals we sought to determine the mechanisms of such changes. LA extrastimulus mapping was performed during CS pacing in 10 patients undergoing first time paroxysmal atrial fibrillation ablation. Bipolar and unipolar electrograms were recorded using a PentaRay catheter (4-4-4 spacing) and indifferent IVC electrode, respectively. An S1S2 pacing protocol was delivered with extrastimulus coupling interval reducing from 350 to 200 milliseconds. At each recording site (119 ± 37 per LA), bipolar peak-to-peak voltage, unipolar peak to peak voltage and activation delay between unipole pairs was measured. Four patterns of bipolar voltage/extrastimulus coupling interval curves were seen: voltage attenuation with plateau voltage >1 mV (48 ± 15%) or voltage unaffected by coupling interval with plateau voltage >1 mV (17 ± 10%) or voltage attenuation were associated with significantly greater unipolar voltage attenuation at low (25 ± 28 mV/s vs. 9 ± 11 mV/s) and high (23 ± 29 mV/s vs. 6 ± 12 mV/s) plateau voltage sites (P voltage attenuation (P = 0.026). Bipolar electrogram voltage is dependent on activation rate at a significant proportion of sites. Changes in unipolar voltage and timing underlie these effects. These observations have important implications for use of voltage mapping to delineate abnormal atrial substrate. © 2017 The Authors. Journal of Cardiovascular Electrophysiology published by Wiley Periodicals, Inc.

  14. Simulation of left atrial function using a multi-scale model of the cardiovascular system.

    Directory of Open Access Journals (Sweden)

    Antoine Pironet

    Full Text Available During a full cardiac cycle, the left atrium successively behaves as a reservoir, a conduit and a pump. This complex behavior makes it unrealistic to apply the time-varying elastance theory to characterize the left atrium, first, because this theory has known limitations, and second, because it is still uncertain whether the load independence hypothesis holds. In this study, we aim to bypass this uncertainty by relying on another kind of mathematical model of the cardiac chambers. In the present work, we describe both the left atrium and the left ventricle with a multi-scale model. The multi-scale property of this model comes from the fact that pressure inside a cardiac chamber is derived from a model of the sarcomere behavior. Macroscopic model parameters are identified from reference dog hemodynamic data. The multi-scale model of the cardiovascular system including the left atrium is then simulated to show that the physiological roles of the left atrium are correctly reproduced. This include a biphasic pressure wave and an eight-shaped pressure-volume loop. We also test the validity of our model in non basal conditions by reproducing a preload reduction experiment by inferior vena cava occlusion with the model. We compute the variation of eight indices before and after this experiment and obtain the same variation as experimentally observed for seven out of the eight indices. In summary, the multi-scale mathematical model presented in this work is able to correctly account for the three roles of the left atrium and also exhibits a realistic left atrial pressure-volume loop. Furthermore, the model has been previously presented and validated for the left ventricle. This makes it a proper alternative to the time-varying elastance theory if the focus is set on precisely representing the left atrial and left ventricular behaviors.

  15. Percutaneous Occlusion of the Left Atrial Appendage with the Watchman Device in an Active Duty Sailor with Atrial Fibrillation and Recurrent Thromboembolism Despite Appropriate Use of Oral Anticoagulation.

    Science.gov (United States)

    Cox, Justin M; Choi, Anthony J; Oakley, Luke S; Francisco, Gregory M; Nayak, Keshav R

    2018-05-23

    Atrial fibrillation is the most common significant cardiac arrhythmia and is associated with a five-fold increased risk of stroke from thromboembolism. Over 94% of these emboli arise from the left atrial appendage. Systemic embolic phenomena are rare, accounting for less than 1 out of 10 of all embolic events, but have a similar prevention strategy. Anticoagulation significantly reduces the risk of these events, and thus forms the cornerstone of therapy for most patients with atrial fibrillation. Left atrial appendage occlusion with the Watchman device is a recently approved alternative for stroke prevention in selected patients. We present a case of an active duty U.S. Navy sailor at low risk for thromboembolism who nonetheless suffered recurrent thromboembolic events despite appropriate anticoagulation, and thus underwent Watchman implantation. The therapy in this case will ideally provide a lifetime of protection from recurrent systemic embolization while allowing the patient to continue his active duty military career without restriction due to oral anticoagulation.

  16. The clot thickens: an incompletely ligated left  atrial appendage

    Directory of Open Access Journals (Sweden)

    Merrill Thomas

    2018-05-01

    Full Text Available Our patient presented with known mechanical mitral valve endocarditis documented by 2D transesophageal echocardiogram (TOE from a recent hospitalization at an outside facility. On admission to our center, there was no prior knowledge of an incompletely ligated left atrial appendage (LAA according to patient- or family-reported history, review of outside records or the outside facility’s 2D TOE report. A 3D TOE performed at our center to assess her pathology, since a month had passed from her prior hospitalization, revealed a LAA ligation with evidence of communication to the left atrium and with clot present in the appendage. This case report highlights the common finding of incomplete closure of the LAA following surgical ligation, thus making it inadequate for stroke prevention in patients with atrial fibrillation, and that 3D TOE plays a valuable role in assessing the durability of LAA ligation.

  17. Unusual case of left atrial myxoma with gastroesophageal junction adenocarcinoma.

    Science.gov (United States)

    Singh, Narinder Pal; Nagpal, Swapan Deep Singh; Goel, Arun Kumar; Dhingra, Bhupendra Kr

    2018-02-01

    Cardiac myxomas are rare tumors. Esophageal adenocarcinomas are common tumors of the gastrointestinal tract. Simultaneous occurrence of these tumors has not been reported. A 52-year-old gentleman presented to our hospital with dysphagia and was diagnosed with esophageal adenocarcinoma. Routine echocardiography discovered a cardiac tumor in the left atrium. The cardiac tumor was surgically removed and biopsy confirmed a myxoma. We removed the cardiac tumor as the first step and then initiated neoadjuvant chemotherapy. It is ideal to constitute a multidisciplinary team to decide on the course of treatment in such cases.

  18. Percutaneous closure of the left atrial appendage with Watchman device: An option for patients with atrial fibrilation and high risk of bleeding with anticoagulation

    Directory of Open Access Journals (Sweden)

    Sénior, Juan

    2015-07-01

    Full Text Available Atrial fibrillation is the most common arrhythmia found in clinical practice, with a population prevalence of 1% to 2%. Anticoagulation remains a fundamental part of treatment for the prevention of cerebrovascular events (stroke, but it is contraindicated in approximately 20% of patients. We report a case of non-valvular atrial fibrillation with high-risk score for stroke, a history of intracerebral bleeding, and very high risk of bleeding with long-term anticoagulation. Percutaneous closure of the left atrial appendage with the Watchman device was performed successfully without complications.

  19. Rotational Angiography Based Three-Dimensional Left Atrial Reconstruction: A New Approach for Transseptal Puncture.

    Science.gov (United States)

    Koektuerk, Buelent; Yorgun, Hikmet; Koektuerk, Oezlem; Turan, Cem H; Gorr, Eduard; Horlitz, Marc; Turan, Ramazan G

    2016-02-01

    Rotational angiography is a well-known method for the three-dimensional (3-D) reconstruction of left atrium and pulmonary veins during left-sided atrial arrhythmia ablation procedures. In our study, we aimed to review our experience in transseptal puncture (TSP) using 3-D rotational angiography. We included a total of 271 patients who underwent atrial fibrillation ablation using cryoballoon. Rotational angiography was performed to get the three-dimensional left atrial and pulmonary vein reconstructions using cardiac C-arm computed tomography. The image reconstruction was made using the DynaCT Cardiac software (Siemens, Erlangen, Germany). The mean age of the study population was 61 ± 10 years. The indications for left atrial arrhythmia ablation were paroxysmal AF in 140 patients (52%) and persistent AF patients in 131 (48%) patients. The success rate of TSP using only rotational guidance was (264/271 patients, 97.4%). In the remaining seven patients, transesophageal guidance was used after the initial attempt due to thick interatrial septum in five patients and difficult TSP due to abnormal anatomy and mild pericardial effusion in the remaining two patients. Mean fluoroscopy dosage of the rotational angiography was 4896.4 ± 825.3 μGym(2). The mean time beginning from femoral vein puncture to TSP was 12.3 ± 5.5 min. TSP guided by rotational angiography is a safe and effective method. Our results indicate that integration of rotational angiographic images into the real-time fluoroscopy can guide the TSP during the procedure. © 2015 John Wiley & Sons Ltd.

  20. Left atrial dysfunction in patients with patent foramen ovale and atrial septal aneurysm: an alternative concurrent mechanism for arterial embolism?

    Science.gov (United States)

    Rigatelli, Gianluca; Aggio, Silvio; Cardaioli, Paolo; Braggion, Gabriele; Giordan, Massimo; Dell'avvocata, Fabio; Chinaglia, Mauro; Rigatelli, Giorgio; Roncon, Loris; Chen, Jack P

    2009-07-01

    We postulate that, in patients with large patent foramen ovales (PFO) and atrial septal aneurysms (ASA), left atrial (LA) dysfunction simulating "atrial fibrillation (AF)-like" pathophysiology might represent an alternate mechanism in the promotion of arterial embolism. Despite prior reports concerning paradoxical embolism through a PFO, the magnitude of this phenomenon as a risk factor for stroke remains undefined, because deep venous thrombosis is infrequently detected in such patients. To test our hypothesis, we prospectively enrolled 98 consecutive patients with previous stroke (mean age 37 +/- 12.5 years, 58 women) referred to our center for catheter-based PFO closure. Baseline values of LA passive and active emptying, LA conduit function, LA ejection fraction, and spontaneous echocontrast (SEC) in the LA and LA appendage were compared with those of 50 AF patients as well as a sex/age/cardiac risk-matched population of 70 healthy control subjects. Pre-closure PFO subjects demonstrated significantly greater reservoir function as well as passive and active emptying, with significantly reduced conduit function and LA ejection fraction, when compared with AF and control patients. Furthermore, in PFO patients, 66.3% (65 of 98) had moderate-to-severe ASA and basal shunt; SEC was observed in 52% of PFO plus ASA patients before closure. Multivariate stepwise logistic regression revealed moderate-to-severe ASA (odds ratio: 9.4, 95% confidence interval: 7.0 to 23.2, p < 0.001) as the most powerful predictor of LA dysfunction. After closure, all LA parameters normalized to the levels of control subjects: no SEC, device-related thrombosis, or aortic erosion were observed on follow-up echocardiography. This study suggests that moderate-to-severe ASA might be associated with LA dysfunction in patients with PFO. The resultant similarities to the pathophysiology of AF might represent an additional contributing mechanism for arterial embolism in such patients.

  1. Comparison of biatrial and left atrial radiofrequency ablation in patients with heart valves diseases

    Directory of Open Access Journals (Sweden)

    А. В. Богачев-прокофьев

    2015-10-01

    Full Text Available We analysed results of left atrial and biatrial anatomic scheme of radiofrequency (RF ablation of the atria in patients with valvular heart. From 2007 to 2011, RF ablation procedure performed 283 patients with atrial fibrillation and heart valve disease. Patients were divided into two groups - group I performed a complete circuit biatrial procedure (procedure maze IV - 131 patients, in group II only ablation of the left atrium -152 patients. Most of the patients had long-term persistent AF. The main problem of early postoperative period is dysfunction of pacemaker complex, which observed in 64.9% and 50.7% patients for group I and II, respectively (p = 0.031. Permanent dysfunction of pacemaker complex required implantation of permanent pacemaker (9.2% and 4.6% of cases for group I and II, respectively, p = 0,023. Predictors of dysfunction of the pacemaker complex were biatrial execution method and duration of AF. Freedom from AF and AT during 36 months after surgery was 80.4% for patients in group I and 78.5% for patients in group II, with no statistically significant difference (log-rank test, p = 0.621. Atrial transport function has not revealed that the active fraction of the right atrium was 29.8% higher than in group II in the early postoperative phase and by 17.9% in the long term, with no difference between groups for the left atrium has been received.

  2. Angiotensin converting enzyme 2 activity and human atrial fibrillation: increased plasma angiotensin converting enzyme 2 activity is associated with atrial fibrillation and more advanced left atrial structural remodelling.

    Science.gov (United States)

    Walters, Tomos E; Kalman, Jonathan M; Patel, Sheila K; Mearns, Megan; Velkoska, Elena; Burrell, Louise M

    2017-08-01

    Angiotensin converting enzyme 2 (ACE2) is an integral membrane protein whose main action is to degrade angiotensin II. Plasma ACE2 activity is increased in various cardiovascular diseases. We aimed to determine the relationship between plasma ACE2 activity and human atrial fibrillation (AF), and in particular its relationship to left atrial (LA) structural remodelling. One hundred and three participants from a tertiary arrhythmia centre, including 58 with paroxysmal AF (PAF), 20 with persistent AF (PersAF), and 25 controls, underwent clinical evaluation, echocardiographic analysis, and measurement of plasma ACE2 activity. A subgroup of 20 participants underwent invasive LA electroanatomic mapping. Plasma ACE2 activity levels were increased in AF [control 13.3 (9.5-22.3) pmol/min/mL; PAF 16.9 (9.7-27.3) pmol/min/mL; PersAF 22.8 (13.7-33.4) pmol/min/mL, P = 0.006]. Elevated plasma ACE2 was associated with older age, male gender, hypertension and vascular disease, elevated left ventricular (LV) mass, impaired LV diastolic function and advanced atrial disease (P < 0.05 for all). Independent predictors of elevated plasma ACE2 activity were AF (P = 0.04) and vascular disease (P < 0.01). There was a significant relationship between elevated ACE2 activity and low mean LA bipolar voltage (adjusted R2 = 0.22, P = 0.03), a high proportion of complex fractionated electrograms (R2 = 0.32, P = 0.009) and a long LA activation time (R2 = 0.20, P = 0.04). Plasma ACE2 activity is elevated in human AF. Both AF and vascular disease predict elevated plasma ACE2 activity, and elevated plasma ACE2 is significantly associated with more advanced LA structural remodelling. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  3. [New technology for prevention of embolic events in atrial fibrillation: a systematic review on percutaneous endovascular left atrial appendage closure].

    Science.gov (United States)

    Danna, Paolo; Sagone, Antonio; Proietti, Riccardo; Arensi, Andrea; Viecca, Maurizio; Santangeli, Pasquale; Di Biase, Luigi; Natale, Andrea

    2012-09-01

    Atrial fibrillation (AF) is the most common cardiac arrhythmia. The mortality rate of patients with AF is doubled as compared to non-fibrillating controls. The most relevant complication of AF is a major increase in the risk of stroke. The gold standard in reducing cerebrovascular events in AF is warfarin therapy, which is not free from contraindications and limitations. The left atrial appendage (LAA) is the main source of emboli causing stroke in AF. LAA closure is a seducing approach to stroke risk reduction in AF without anticoagulation. Since 1949, heart surgeons have performed LAA closure or amputation in patients with AF. Percutaneous endovascular LAA closure is a new, less invasive, technique to reach the goal. Several devices have been used to perform this intervention, and the results of published trials are encouraging in terms of effectiveness and relative safety of this attractive technique. In this review we examine the published trials and data on percutaneous LAA closure, with particular attention to the risks and benefits of this procedure.

  4. Percutaneous left atrial appendage occlusion in atrial fibrillation patients with a contraindication to oral anticoagulation: a focused review.

    Science.gov (United States)

    Nishimura, Marin; Sab, Shiv; Reeves, Ryan R; Hsu, Jonathan C

    2017-12-08

    Stroke is the most feared complication of atrial fibrillation (AF). Although oral anticoagulation with non-vitamin K antagonist and non-vitamin K antagonist oral anticoagulants (NOACs) have been established to significantly reduce risk of stroke, real-world use of these agents are often suboptimal due to concerns for adverse events including bleeding from both patients and clinicians. Particularly in patients with previous serious bleeding, oral anticoagulation may be contraindicated. Left atrial appendage occlusion (LAAO), mechanically targeting the source of most of the thrombi in AF, holds an immense potential as an alternative to OAC in management of stroke prophylaxis. In this focused review, we describe the available evidence of various LAAO devices, detailing data regarding their use in patients with a contraindication for oral anticoagulation. Although some questions of safety and appropriate use of these new devices in patients who cannot tolerate anticoagulation remain, LAAO devices offer a significant step forward in the management of patients with AF, including those patients who may not be able to be prescribed OAC at all. Future studies involving patients fully contraindicated to OAC are warranted in the era of LAAO devices for stroke risk reduction. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  5. Left atrial appendage closure: Six reasons why I wouldn't choose a percutaneous closure for my appendage.

    Science.gov (United States)

    Ferlini, Marco; Rossini, Roberta

    2018-01-15

    Left atrial appendage has been shown as a primary source of thrombi in patients with non-valvular atrial fibrillation (AF). Non vitamin k oral anticoagulants (NOAC) have been shown to be safe and effective in the prevention of embolic complications. Current guidelines on AF state that percutaneous left atrial appendage closure (LAAC) might be considered in patients with contraindication to long term oral anticoagulant therapy (OAC). An overview of the main trials on NOAC and LAAC is provided. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Evaluation of left atrial function by multidetector computed tomography before left atrial radiofrequency-catheter ablation: Comparison of a manual and automated 3D volume segmentation method

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, Florian, E-mail: florian.wolf@meduniwien.ac.a [Department of Radiology, Medical University of Vienna, Vienna (Austria); Ourednicek, Petr [Philips Medical Systems, Prague (Czech Republic); Loewe, Christian [Department of Radiology, Medical University of Vienna, Vienna (Austria); Richter, Bernhard; Goessinger, Heinz David; Gwechenberger, Marianne [Department of Cardiology, Medical University of Vienna, Vienna (Austria); Plank, Christina; Schernthaner, Ruediger Egbert; Toepker, Michael; Lammer, Johannes [Department of Radiology, Medical University of Vienna, Vienna (Austria); Feuchtner, Gudrun M. [Department of Radiology, Innsbruck Medical University, Innsbruck (Austria); Institute of Diagnostic Radiology, University Hospital Zurich (Switzerland)

    2010-08-15

    Introduction: The purpose of this study was to compare a manual and automated 3D volume segmentation tool for evaluation of left atrial (LA) function by 64-slice multidetector-CT (MDCT). Methods and materials: In 33 patients with paroxysmal atrial fibrillation a MDCT scan was performed before radiofrequency-catheter ablation. Atrial function (minimal volume (LAmin), maximal volume (LAmax), stroke volume (SV), ejection fraction (EF)) was evaluated by two readers using a manual and an automatic tool and measurement time was evaluated. Results: Automated LA volume segmentation failed in one patient due to low LA enhancement (103HU). Mean LAmax, LAmin, SV and EF were 127.7 ml, 93 ml, 34.7 ml, 27.1% by the automated, and 122.7 ml, 89.9 ml, 32.8 ml, 26.3% by the manual method with no significant difference (p > 0.05) and high Pearsons correlation coefficients (r = 0.94, r = 0.94, r = 0.82 and r = 0.85, p < 0.0001), respectively. The automated method was significantly faster (p < 0.001). Interobserver variability was low for both methods with Pearson's correlation coefficients between 0.98 and 0.99 (p < 0.0001). Conclusions: Evaluation of LA volume and function with 64-slice MDCT is feasible with a very low interobserver variability. The automatic method is as accurate as the manual method but significantly less time consuming permitting a routine use in clinical practice before RF-catheter ablation.

  7. Assessment of the effect of left atrial cryoablation enhanced by ganglionated plexi ablation in the treatment of atrial fibrillation in patients undergoing open heart surgery.

    Science.gov (United States)

    Bárta, Jiří; Brát, Radim

    2017-08-17

    The aim of our study was to investigate, whether enhancement of left atrial cryoablation by ablation of the autonomic nervous system of left atrium leads to influencing the outcomes of surgical treatment of atrial fibrillation in patients with structural heart disease undergoing open-heart surgery. The observed patient file consisted of 100 patients, who have undergone a combined open-heart surgery at our department between July 2012 and December 2014. The patients were indicated for the surgical procedure due to structural heart disease, and suffered from paroxysmal, persistent, or long-standing persistent atrial fibrillation. In all cases, left atrial cryoablation was performed in the extent of isolation of pulmonary veins, box lesion, connecting lesion with mitral annulus, amputation of the left atrial appendage and connecting lesion of the appendage base with left pulmonary veins. Furthermore, 35 of the patients underwent mapping and radiofrequency ablation of ganglionated plexi, together with discision and ablation of the ligament of Marshall (Group GP). A control group was consisted of 65 patients without ganglionated plexi intervention (Group LA). The main primary outcome was establishment and duration of sinus rhythm in the course of one-year follow-up. Evaluation of the number of patients with a normal sinus rhythm in per cent has shown comparable values in both groups (Group GP - 93.75%, Group LA - 86.67%, p = 0.485); comparable results were also observed in patients with normal sinus rhythm without anti-arrhythmic treatment in the 12th month (Group GP - 50%, Group LA - 47%, p = 0.306). We have not observed any relation between the recurrence of atrial fibrillation and the presence of a mitral valve surgery, or between the presence of a mitral and tricuspid valves surgery and between the left atrial diameter > 50 mm. Enhancement of left atrial cryoablation by gangionated plexi ablation did not influence the outcomes of surgical ablation due to

  8. Small atrial septal defect associated with heart failure in an infant with a marginal left ventricle

    Directory of Open Access Journals (Sweden)

    Sandra D.K. Kingma

    2012-07-01

    Full Text Available Atrial septal defect (ASD is usually asymptomatic in infancy, unless pulmonary hypertension or severe co-morbidity is present. We report a case of a 4-week-old infant with moderate- sized ASD, small patent ductus arteriosus (PDA, and a borderline sized left ventricle that developed heart failure. Despite the relatively small diameter of the ASD, this defect influenced the mechanism of heart failure significantly. After surgical closure of both PDA and ASD, the signs of pulmonary hypertension resolved and the patient developed a normal sized left ventricle. This report illustrates that the presence of a small ASD in combination with a marginal left ventricle may result in inadequate left ventricular filling, pulmonary hypertension and heart failure.

  9. Left atrial leiomyosarcoma as cause of heart failure; Leiomiosarcoma atrial izquierdo como causa de insuficiencia cardiaca

    Energy Technology Data Exchange (ETDEWEB)

    Valdes Martin, Alexander [Instituto de Cardiologia y Cirugia Cardiovascular, La Habana (Cuba)

    2012-07-01

    The case of a 26 year-old patient with diagnosis of heart failure and presence of a mobile echogenic mass without calcification attached to the posterolateral area of the left atrium was reported. She underwent surgery and tissue examination evidenced a high-grade heart leiomyosarcoma. Postoperative course was satisfactory and her clinical state was rigorously monitored by oncology and heart specialists in the institution.

  10. Significant correlation of P-wave parameters with left atrial volume index and left ventricular diastolic function.

    Science.gov (United States)

    Tsai, Wei-Chung; Lee, Kun-Tai; Wu, Ming-Tsang; Chu, Chih-Sheng; Lin, Tsung-Hsien; Hsu, Po-Chao; Su, Ho-Ming; Voon, Wen-Chol; Lai, Wen-Ter; Sheu, Sheng-Hsiung

    2013-07-01

    The 12-lead electrocardiogram (ECG) is a commonly used tool to access left atrial enlargement, which is a marker of left ventricular diastolic dysfunction (LVDD). The aim of this study was to evaluate any association of the P-wave measurements in ECG with left atrial volume (LAV) index and LVDD. This study enrolled 270 patients. In this study, 4 ECG P-wave parameters corrected by heart rate, that is, corrected P-wave maximum duration (PWdurMaxC), corrected P-wave dispersion (PWdisperC), corrected P-wave area (PWareaC) and corrected mean P-wave duration (meanPWdurC), were measured. LAV and left ventricular diastolic parameters were measured from echocardiography. LVDD was defined as a pseudonormal or restrictive mitral inflow pattern. The 4 P-wave parameters were significantly correlated with the LAV index after adjusting for age, sex, diabetes, hypertension, coronary artery disease, body mass index and diastolic blood pressure in multivariate analysis. The standardized β coefficients of PWdurMaxC, PWdisperC, meanPWdurC and PWareaC were 0.338, 0.298, 0.215 and 0.296, respectively. The 4 P-wave parameters were also significantly correlated with LVDD after multivariate logistic regression analysis. The odds ratios (95% confidence intervals) of PWdurMaxC, PWdisperC, meanPWdurC and PWareaC were 1.03 (1.01-1.04), 1.02 (1.04-1.04), 1.04 (1.02-1.07) and 1.01 (1.00-1.02), respectively. This study demonstrated that PWdurMaxC, PWdisperC, meanPWdurC and PWareaC were important determinants of the LAV index and LVDD. Therefore, screening patients by means of the 12-lead ECG may be helpful in identifying a high-risk group of increased LAV index and LVDD.

  11. [Comparison of ablation of left-sided accessory pathway by atrial septal and retrograde arterial approach].

    Science.gov (United States)

    Zhu, J G; Bao, Z Y; Gu, X

    2017-03-07

    Objective: To compare the advantages and disadvantages of radiofrequency ablation of left-sided accessory pathways by via atrial septal approach with retrograde through aortic approach. Methods: A total of 184 patients of left-side accessory pathways were treated in Taizhou People's Hospital and the Subei People's Hospital from March 2012 to August 2015.A total of 103 cases were treated by aortic retrograde approach as through arterial group, 81 cases were treated by punctured atrial septal to left atrial for mapping and ablation as through atrial septal group.Comparison of ablation procedure time, total and pathways of different parts(subgroup) at instant success and relapse rates, safety (serious complications), and statistics other complications in operation and postoperative. Results: Through arterial group and through atrial septal group were no significant difference ( P >0.05) in the ablation procedure time((25±18 ) vs (22±15)min ), instant success(98.1% vs 97.5%) and relapse rates(1.0% vs 1.2%), security(1 vs 0 case). There was no statistical difference in septal part subgroups (all P >0.05) in the ablation procedure time((22±18)vs (25±19)min), instant success(91.7% vs 89.9 %) and relapse rates(0 vs 11.1%); posterior wall subgroup had no statistical difference in the ablation procedure time((18±15)vs (16±12)min), instant success(100% vs 100 %) and relapse rates(0 vs 0)(all P >0.05); side wall subgroup had no statistical difference in the ablation procedure time((29±20)vs (21±18) min), instant success (98.3% vs 98.1%)and relapse rates(1.7% vs 0%)(all P >0.05). Conclusion: Ablation of left-sided accessory pathways by transseptal approach and transaortic approach has no statistical difference in the procedure time, instant success and relapse rates, security.In a particular case, there is a certain complementarity between the two methods.

  12. 5-Year Outcomes After Left Atrial Appendage Closure: From the PREVAIL and PROTECT AF Trials.

    Science.gov (United States)

    Reddy, Vivek Y; Doshi, Shephal K; Kar, Saibal; Gibson, Douglas N; Price, Matthew J; Huber, Kenneth; Horton, Rodney P; Buchbinder, Maurice; Neuzil, Petr; Gordon, Nicole T; Holmes, David R

    2017-12-19

    The PROTECT AF (WATCHMAN Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation) trial demonstrated that left atrial appendage closure (LAAC) with the Watchman device (Boston Scientific, St. Paul, Minnesota) was equivalent to warfarin for preventing stroke in atrial fibrillation, but had a high rate of complications. In a second randomized trial, PREVAIL (Evaluation of the WATCHMAN LAA Closure Device in Patients With Atrial Fibrillation Versus Long Term Warfarin Therapy), the complication rate was low. The warfarin cohort experienced an unexpectedly low ischemic stroke rate, rendering the efficacy endpoints inconclusive. However, these outcomes were based on relatively few patients followed for a relatively short time. The final results of the PREVAIL trial, both alone and as part of a patient-level meta-analysis with the PROTECT AF trial, are reported with patients in both trials followed for 5 years. PREVAIL and PROTECT AF are prospective randomized clinical trials with patients randomized 2:1 to LAAC or warfarin; together, they enrolled 1,114 patients for 4,343 patient-years. Analyses are by intention-to-treat, and rates are events per 100 patient-years. For the PREVAIL trial, the first composite coprimary endpoint of stroke, systemic embolism (SE), or cardiovascular/unexplained death did not achieve noninferiority (posterior probability for noninferiority = 88.4%), whereas the second coprimary endpoint of post-procedure ischemic stroke/SE did achieve noninferiority (posterior probability for noninferiority = 97.5%); the warfarin arm maintained an unusually low ischemic stroke rate (0.73%). In the meta-analysis, the composite endpoint was similar between groups (hazard ratio [HR]: 0.820; p = 0.27), as were all-stroke/SE (HR: 0.961; p = 0.87). The ischemic stroke/SE rate was numerically higher with LAAC, but this difference did not reach statistical significance (HR: 1.71; p = 0.080). However, differences in

  13. Left atrial remodelling in patients with myocardial infarction complicated by heart failure, left ventricular dysfunction, or both: the VALIANT Echo study

    DEFF Research Database (Denmark)

    Meris, Alessandra; Amigoni, Maria; Uno, Hajime

    2009-01-01

    AIMS: To assess the relationship between left atrial (LA) size and outcome after high-risk myocardial infarction (MI) and to study dynamic changes in LA size during long-term follow-up. METHODS AND RESULTS: The VALIANT Echocardiography study prospectively enrolled 610 patients with left ventricul...

  14. Long-term survival of quiescent left atrial myxoma in an elderly patient.

    Science.gov (United States)

    Kay, Jay F L; Chow, Wing Hing

    2002-01-01

    Left atrial myxoma, if left untreated, is inexorably progressive and usually fatal. The classical management of this disease is prompt surgical removal. However, there may be exceptions to this traditional dogma. The authors report an 85-year-old man who presented with features of chronic obstructive airway disease and congestive heart failure 15 years previously. Auscultation of the heart showed a pansystolic murmur. Two-dimensional echocardiography revealed a nonobstructive, calcified, and well circumscribed mass in the left atrium, with a pedicle attached to the interatrial septum. Because the patient refused high-risk cardiac surgery related to his comorbidity, he was managed medically with a bronchodilator, diuretics, and digoxin. There have been no features of embolism or intracardiac obstruction, and serial echocardiography demonstrates no disease progression over this long period of time. This case illustrates that calcified left atrial myxoma may exhibit a quiescent phase. Tumor calcification, slow growth potential, and the absence of intracardiac obstruction may correlate with a better outcome in the elderly patient. (c)2002 CVRR, Inc.

  15. Infective Endocarditis of the Left Main to Right Atrial Coronary Cameral Fistula

    Science.gov (United States)

    Mishra, Ramesh Chandra; Barik, Ramachandra; Patnaik, Amar Narayana

    2016-01-01

    A 7-year-old female child presented with pyrexia of unknown origin. She had received an empirical regimen of antibiotic for possible endocarditis. Evaluation included multiple imaging supports and blood culture. She had left main coronary artery to right atrium coronary cameral fistula, restricted patent ductus arteriosus, vegetation at the right atrial exit of fistula and negative blood culture. Ongoing fever more than 2 weeks, oscillating vegetation in the echo and histopathological evidence of healing vegetation suggested definite diagnosis of infective endocarditis. She was treated successfully by surgical closure of fistula from the right atrial approach. Device closure in this case would have resulted in a large residual cul-de-sac with or without tiny residual high-velocity jets, either being a threat for future enlargement, rupture of the residual aneurysmal sac, thromboembolism, prolonged anticoagulation, and infective endocarditis. PMID:28465978

  16. The importance of integrated left atrial evaluation: From hypertension to heart failure with preserved ejection fraction.

    Science.gov (United States)

    Beltrami, Matteo; Palazzuoli, Alberto; Padeletti, Luigi; Cerbai, Elisabetta; Coiro, Stefano; Emdin, Michele; Marcucci, Rossella; Morrone, Doralisa; Cameli, Matteo; Savino, Ketty; Pedrinelli, Roberto; Ambrosio, Giuseppe

    2018-02-01

    Functional analysis and measurement of left atrium are an integral part of cardiac evaluation, and they represent a key element during non-invasive analysis of diastolic function in patients with hypertension (HT) and/or heart failure with preserved ejection fraction (HFpEF). However, diastolic dysfunction remains quite elusive regarding classification, and atrial size and function are two key factors for left ventricular (LV) filling evaluation. Chronic left atrial (LA) remodelling is the final step of chronic intra-cavitary pressure overload, and it accompanies increased neurohormonal, proarrhythmic and prothrombotic activities. In this systematic review, we aim to purpose a multi-modality approach for LA geometry and function analysis, which integrates diastolic flow with LA characteristics and remodelling through application of both traditional and new diagnostic tools. The most important studies published in the literature on LA size, function and diastolic dysfunction in patients with HFpEF, HT and/or atrial fibrillation (AF) are considered and discussed. In HFpEF and HT, pulsed and tissue Doppler assessments are useful tools to estimate LV filling pressure, atrio-ventricular coupling and LV relaxation but they need to be enriched with LA evaluation in terms of morphology and function. An integrated evaluation should be also applied to patients with a high arrhythmic risk, in whom eccentric LA remodelling and higher LA stiffness are associated with a greater AF risk. Evaluation of LA size, volume, function and structure are mandatory in the management of patients with HT, HFpEF and AF. A multi-modality approach could provide additional information, identifying subjects with more severe LA remodelling. Left atrium assessment deserves an accurate study inside the cardiac imaging approach and optimised measurement with established cut-offs need to be better recognised through multicenter studies. © 2017 John Wiley & Sons Ltd.

  17. Left atrial appendage segmentation and quantitative assisted diagnosis of atrial fibrillation based on fusion of temporal-spatial information.

    Science.gov (United States)

    Jin, Cheng; Feng, Jianjiang; Wang, Lei; Yu, Heng; Liu, Jiang; Lu, Jiwen; Zhou, Jie

    2018-05-01

    In this paper, we present an approach for left atrial appendage (LAA) multi-phase fast segmentation and quantitative assisted diagnosis of atrial fibrillation (AF) based on 4D-CT data. We take full advantage of the temporal dimension information to segment the living, flailed LAA based on a parametric max-flow method and graph-cut approach to build 3-D model of each phase. To assist the diagnosis of AF, we calculate the volumes of 3-D models, and then generate a "volume-phase" curve to calculate the important dynamic metrics: ejection fraction, filling flux, and emptying flux of the LAA's blood by volume. This approach demonstrates more precise results than the conventional approaches that calculate metrics by area, and allows for the quick analysis of LAA-volume pattern changes of in a cardiac cycle. It may also provide insight into the individual differences in the lesions of the LAA. Furthermore, we apply support vector machines (SVMs) to achieve a quantitative auto-diagnosis of the AF by exploiting seven features from volume change ratios of the LAA, and perform multivariate logistic regression analysis for the risk of LAA thrombosis. The 100 cases utilized in this research were taken from the Philips 256-iCT. The experimental results demonstrate that our approach can construct the 3-D LAA geometries robustly compared to manual annotations, and reasonably infer that the LAA undergoes filling, emptying and re-filling, re-emptying in a cardiac cycle. This research provides a potential for exploring various physiological functions of the LAA and quantitatively estimating the risk of stroke in patients with AF. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Total and interatrial epicardial adipose tissues are independently associated with left atrial remodeling in patients with atrial fibrillation.

    Science.gov (United States)

    Shin, Seung Yong; Yong, Hwan Seok; Lim, Hong Euy; Na, Jin Oh; Choi, Cheol Ung; Choi, Jong Il; Kim, Seong Hwan; Kim, Jin Won; Kim, Eung Ju; Park, Sang Weon; Rha, Seung-Woon; Park, Chang Gyu; Seo, Hong Seog; Oh, Dong Joo; Kim, Young-Hoon

    2011-06-01

    As epicardial adipose tissue (EAT) is a metabolically active visceral fat, potential interaction between EAT and myocardium is strongly suggested. The aims of this study were to determine whether the amount and regional distribution of EAT are related to the chronicity of atrial fibrillation (AF) and left atrial (LA) remodeling. This study consisted of 40 subjects with paroxysmal AF (PAF) and 40 with persistent AF (PeAF). Eighty subjects with no history of AF were enrolled as controls. Total volume of EAT (EAT(total)), regional thickness of EAT, and LA volume (LAV) were measured by multislice computed tomography. In the AF group, blood samples were drawn from coronary sinus for analysis of inflammatory cytokines including adiponectin. Compared with controls, AF subjects had larger LAV, EAT(total), and the thicknesses of periatrial EAT including interatrial septum (IAS). However, the thicknesses of periventricular EAT were not different between the groups. The PeAF subjects had larger LAV, EAT(total), and periatrial EAT thicknesses, higher levels of inflammatory cytokines, and lower level of adiponectin than did the PAF subjects. Adiponection level was significantly associated with EAT(total) and IAS thickness. Multivariate analysis revealed that EAT(total) (P = 0.004) and IAS thickness (P = 0.016) were independently associated with LAV. EAT(total) and thickness of periatrial EAT were significantly larger in AF subjects compared to those of the matched controls and were closely related to the chronicity of AF. Moreover, EAT(total) and IAS thickness were independently associated with LAV in subjects with AF. © 2011 Wiley Periodicals, Inc.

  19. Left atrial appendage myxofibrosarcoma: A rare masquerader of myxoma and thrombus-"all that glitters is not gold".

    Science.gov (United States)

    Khan, Muhammad Shoaib; Reddy, Sahadev; Lombardi, Richard; Isabel, Pitti; Mcgregor, Walter E; Tang, Bang; Gabriel, George; Biederman, Robert W

    2018-02-01

    Left atrial appendage mass can occasionally pose a serious challenge to physicians to identify the nature of the mass with the aid of imaging techniques. We present a case of 67-year-old man, who was evaluated for suspected left atria myxoma. Transesophageal echocardiography revealed a heterogeneous density originating from left atrial appendage, thought to be most consistent with a myxoma. Cardiac magnetic resonance imaging, uncharacteristically, gave an equivocal picture, suggesting the mass to be a myxoma on initial imaging and a thrombus with evidence of liquefaction necrosis following postcontrast enhancement. Surprisingly, histopathology of the mass following its surgical excision yielded a rare diagnosis of myxofibrosarcoma. © 2017, Wiley Periodicals, Inc.

  20. Clinical study on left atrial thrombi. Comparative study between echocardiography and CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Shimada, E; Asano, H; Kurasawa, T; Mitsumoto, K; Yamane, Y [Tokyo Kosei-Nenkin Hospital (Japan)

    1981-09-01

    We studied left atrial thrombi (LAT) by both echocardiography and computed tomography (CT) and compared the features of the 2 methods. A total of 15 patients with mitral stenosis complicated by atrial fibrillation were selected as the subjects. LAT were noted on the M-mode echocardiograms in 2 patients including a questionably positive one, on the two-dimensional echocardiograms in 5, and on the CT scans in 6 of 15. The history of thromboembolism was rather frequent and was found in 7 of 15 patients. However, LAT was found in only 3 of these on the CT scans. A shaggy or fuzzy pattern on the M-mode echocardiogram cannot be regarded as representing thrombi, while a laminar pattern undoubtedly represented thrombi. Two-dimensional echocardiography has considerably contributed to the improved detection rate of LAT. For the characteristic properties of ultrasound beams, however, it was impossible to investigate the entire left atrium. The detection of the thrombi in the appendage was especially difficult. However, computed tomography, permitting transverse cross-sectional tomography, was capable of sectioning the heart even in the presence of air and bones. The measurement of CT values was suggestive of the properties of the substance or substances involved, and also allowed the presumption as to whether the thrombus has been fibrosed. Furthermore, it was possible to estimate more accurately as well as 3-dimensionally the location, shape and dimensions of the thrombi by the reconstruction of the heart according to the CT values. It was concluded that echocardiography and computed tomography are the mutual aid to further improvement in the detection rate of left atrial thrombi.

  1. Outcomes following the Kawashima procedure for single-ventricle palliation in left atrial isomerism.

    Science.gov (United States)

    Vollebregt, Anne; Pushparajah, Kuberan; Rizvi, Maleeha; Hoschtitzky, Andreas; Anderson, David; Austin, Conal; Tibby, Shane M; Simpson, John

    2012-03-01

    Patients with left atrial isomerism and interrupted inferior vena cava palliated with a superior cavopulmonary connection or Kawashima procedure (KP) have a high incidence of developing pulmonary arteriovenous malformations. The necessity for hepatic vein redirection (HVR) and its timing remains a controversy. We aimed to assess the clinical outcome of patients with left atrial isomerism following a KP. The main end points were death, requirement for HVR and the impact of HVR on oxygen saturation. Retrospective review of 21 patients with a diagnosis of left atrial isomerism, interruption of the inferior vena cava and single-ventricle physiology managed with a KP at a single centre between January 1990 and March 2010. Twenty-one patients had a KP, with 12 subsequently undergoing HVR. There was relatively a constant monthly decrement in the proportion of patients who were free from death or HVR up until 60 months following the KP, with a dramatic increase in the hazard after this time. The Cox proportional hazards regression model demonstrated a reduced early risk for HVR or death in patients who underwent pulmonary artery banding versus arterial shunt as the primary procedure (hazard ratio: 0.10; P = 0.01), and an increased risk with bilateral superior vena cavas (SVCs) (hazard ratio: 3.4; P = 0.04) and age at KP (hazard ratio: 1.02 per month increase in age at KP; P = 0.02). HVR mortality was relatively high with 3 of 12 patients dying in the early postoperative period with profound cyanosis. The timing of HVR after the KP did not influence the postoperative rate of increase in oxygen saturation. These findings confirm that the majority of patients who undergo a KP will require HVR. Patients who are older at the time of the KP or having an initial arterial shunt or bilateral SVCs are at higher risk of HVR or death. The relatively high mortality at HVR was characterized by severe postoperative cyanosis.

  2. Evaluation of single right atrial volume and function with magnetic resonance imaging in children with hypoplastic left heart

    Energy Technology Data Exchange (ETDEWEB)

    Vijarnsorn, Chodchanok [University of Alberta, Faculty of Medicine and Dentistry, Stollery Children' s Hospital, Edmonton, AB (Canada); Mahidol University, Siriraj Hospital, Bangkok (Thailand); Myers, Kimberley; Patton, David J. [Alberta Children' s Hospital, Section of Pediatric Cardiology, Department of Pediatrics, Department of Pediatrics, Calgary, AB (Canada); Noga, Michelle; Crawley, Cinzia; Tham, Edythe [University of Alberta, Faculty of Medicine and Dentistry, Stollery Children' s Hospital, Edmonton, AB (Canada)

    2016-06-15

    Standardized methods to evaluate atrial properties in single ventricles are lacking. To determine the feasibility of quantifying right atrial volumes and function in hypoplastic left heart using MRI. We studied 15 infants with hypoplastic left heart prior to Glenn surgery (mean age 4.2 months [standard deviation 0.3]) who underwent cardiac MRI with evaluation of atrial volumes and emptying fraction using monoplane two-chamber, monoplane four-chamber, and biplane methods, all of which were compared to the atrial short-axial oblique stack method. We compared atrial end-diastolic volume, end-systolic volume and emptying fraction among these methods. We analyzed reproducibility of the methods using Bland-Altman plots. Both four-chamber and biplane methods showed high correlations for atrial end-diastolic volume (r = 0.7 and r = 0.8, respectively; P < 0.01) and end-systolic volume (r = 0.8 and r = 0.9, respectively; P < 0.01) with small mean differences (-0.2 ± 2.9 standard deviation [SD] ml and -0.8 ± 1.6 ml, respectively, for atrial end-diastolic volume and -0.8 ± 1.5 ml and -0.9 ± 0.9 ml, respectively, for atrial end-systolic volume). The short-axial oblique method was the most reproducible, followed by the four-chamber method. MRI assessment of atrial volume and function is feasible in hypoplastic left heart and might provide further insight into single-ventricle mechanics. (orig.)

  3. Left atrial mass 16 years after radiation therapy for mediastinal neuroblastoma

    International Nuclear Information System (INIS)

    Ensing, G.J.; Driscoll, D.J.; Smithson, W.A.

    1987-01-01

    Tumors involving the heart during childhood are rare. However, neuroblastoma, a common pediatric malignancy, has been described to involve the cardiovascular system in 3%-12% of patients dying with this tumor. Rarely is such involvement diagnosed ante mortem and never, to our knowledge, has a benign cardiac tumor been reported to present in childhood after successful eradication of neuroblastoma. We describe the identification and surgical resection of a nodular, hypertrophied, calcified, pedunculated left atrial mass in a 16-year-old boy who was complaining of exercise-associated presyncope and headaches 16 years after irradiation and chemotherapy for mediastinal neuroblastoma

  4. Case Report of a Left Atrial Myxoma Associated with Carney%u2019s Syndrome

    Directory of Open Access Journals (Sweden)

    Anil Ozen

    2016-05-01

    Full Text Available Primary cardiac neoplasms are very rare as compared to metastatic tumors. 70% to 80% of them are benign myxomas. Complications of myxomas include cyst and microabscess formation, embolization, syncope and sudden death. Rarely, cardiac myxomas are associated with primary nodular adrenal cortical disease, mammary fibroadenomas, testicular tumors or pitiutary adenomas with gigantism or acromegaly known as Carney%u2019s syndrome. We present a patient with a left atrial myxoma who underwent reoperation associated with Carney%u2019s syndrome.

  5. Diagnosing Paroxysmal Atrial Fibrillation in Patients With Ischemic Strokes and Transient Ischemic Attacks Using Echocardiographic Measurements of Left Atrium Function

    DEFF Research Database (Denmark)

    Skaarup, Kristoffer Grundtvig; Christensen, Hanne Krarup; Høst, Nis

    2016-01-01

    Twenty-five to 35 percentage of stroke cases are cryptogenic, and it has been demonstrated that paroxysmal atrial fibrillation (AF) is the causal agent in up to 25% of these incidents. The purpose of this study was to investigate if left atrial (LA) parameters have value for diagnosing paroxysmal...... with paroxysmal AF. However, the atrial measurements evaluating LA function (min LA volume and LA emptying fraction) were significantly different (LA emptying fraction: 45% ± 10% vs 50% ± 10%, p = 0.004; minimal LA volume: 30.2 ml ± 17.3 ml vs 24 ml ± 10 ml, p = 0.035 in patients with paroxysmal AF, even after...

  6. Accessory left atrial diverticulae: contractile properties depicted with 64-slice cine-cardiac CT.

    LENUS (Irish Health Repository)

    Killeen, Ronan P

    2012-02-01

    To assess the contractility of accessory left atrial appendages (LAAs) using multiphasic cardiac CT. We retrospectively analyzed the presence, location, size and contractile properties of accessory LAAs using multiphasic cardiac 64-slice CT in 102 consecutive patients (63 males, 39 females, mean age 57). Multiplanar reformats were used to create image planes in axial oblique, sagittal oblique and coronal oblique planes. For all appendages with an orifice diameter >or= 10 mm, axial and sagittal diameters and appendage volumes were recorded in atrial diastole and systole. Regression analysis was performed to assess which imaging appearances best predicted accessory appendage contractility. Twenty-three (23%) patients demonstrated an accessory LAA, all identified along the anterior LA wall. Dimensions for axial oblique (AOD) and sagittal oblique (SOD) diameters and sagittal oblique length (SOL) were 6.3-19, 3.4-20 and 5-21 mm, respectively. All appendages (>or=10 mm) demonstrated significant contraction during atrial systole (greatest diameter reduction was AOD [3.8 mm, 27%]). Significant correlations were noted between AOD-contraction and AOD (R = 0.57, P < 0.05) and SOD-contraction and AOD, SOD and SOL (R = 0.6, P < 0.05). Mean diverticulum volume in atrial diastole was 468.4 +\\/- 493 mm(3) and in systole was 171.2 +\\/- 122 mm(3), indicating a mean change in volume of 297.2 +\\/- 390 mm(3), P < 0.0001. Stepwise multiple regression analysis revealed SOL to be the strongest independent predictor of appendage contractility (R(2) = 0.86, P < 0.0001) followed by SOD (R(2) = 0.91, P < 0.0001). Accessory LAAs show significant contractile properties on cardiac CT. Those accessory LAAs with a large sagittal height or depth should be evaluated for contractile properties, and if present should be examined for ectopic activity during electrophysiological studies.

  7. Beat-to-beat left ventricular performance in atrial fibrillation: radionuclide assessment with the computerized nuclear probe

    International Nuclear Information System (INIS)

    Schneider, J.; Berger, H.J.; Sands, M.J.; Lachman, A.B.; Zaret, B.L.

    1983-01-01

    There is wide beat-to-beat variability in cycle length and left ventricular performance in patients with atrial fibrillation. In this study, left ventricular ejection fraction and relative left ventricular volumes were evaluated on a beat-to-beat basis with the computerized nuclear probe, an instrument with sufficiently high sensitivity to allow continuous evaluation of the radionuclide time-activity curve. Of 18 patients with atrial fibrillation, 5 had mitral stenosis, 6 had mitral regurgitation, and 7 had coronary artery disease. Fifty consecutive beats were analyzed in each patient. The mean left ventricular ejection fraction ranged from 17 to 51%. There was substantial beat-to-beat variation in cycle length and left ventricular ejection fraction in all patients, including those with marked left ventricular dysfunction. In 14 patients who also underwent multiple gated cardiac blood pool imaging, there was an excellent correlation between mean ejection fraction derived from the nuclear probe and gated ejection fraction obtained by gamma camera imaging (r . 0.90). Based on beat-to-beat analysis, left ventricular function was dependent on relative end-diastolic volume and multiple preceding cycle lengths, but not preceding end-systolic volumes. This study demonstrates that a single value for left ventricular ejection fraction does not adequately characterize left ventricular function in patients with atrial fibrillation. Furthermore, both the mean beat-to-beat and the gated ejection fraction may underestimate left ventricular performance at rest in such patients

  8. Left atrial passive emptying function is preserved in patients with permanent atrial fibrillation--a 320-slice multidetector computed tomography study

    DEFF Research Database (Denmark)

    Agner, Bue Fridolin Ross; Kühl, Jørgen Tobias; Kofoed, Klaus Fuglsang

    2014-01-01

    OBJECTIVE: Left atrial (LA) mechanical function is thought to be virtually inexistent in patients with permanent atrial fibrillation (AF). Due to recent advances in multidetector computed tomography (MDCT) technology, it is now possible to acquire images of the entire heart in a single heartbeat....... The objective of this study was to compare individual components of LA function assessed by MDCT in patients with permanent AF and patients in sinus rhythm (SR). METHODS: 320-slice MDCT was performed in 30 patients with permanent AF. Measurements of LA volumes during the cardiac cycle were compared to 30......; 71 vs. 30 ml/m(2), p permanent AF have significantly increased LA volumes throughout the cardiac...

  9. Excessive interatrial adiposity is associated with left atrial remodeling, augmented contractile performance in asymptomatic population

    Directory of Open Access Journals (Sweden)

    Yau-Huei Lai

    2016-05-01

    Full Text Available Purpose: Pericardial adipose tissue had been shown to exert local effects on adjacent cardiac structures. Data regarding the mechanistic link between such measures and left atrial (LA structural/functional remodeling, a clinical hallmark of early stage heart failure (HF and atrial fibrillation (AF incidence, in asymptomatic population remain largely unexplored. Methods: This retrospective analysis includes 356 subjects free from significant valvular disorders, atrial fibrillation, or clinical HF. Regional adipose tissue including pericardial and periaortic fat volumes, interatrial septal (IAS, and left atrioventricular groove (AVG fat thickness were all measured by multidetector computed tomography (MDCT (Aquarius 3D Workstation, TeraRecon, San Mateo, CA, USA. We measured LA volumes, booster performance, reservoir capacity as well as conduit function, and analyzed their association with adiposity measures. Results: All four adiposity measures were positively associated with greater LA volumes (all P < 0.05, while IAS and AVG fat were also related to larger LA kinetic energy and worse reservoir capacity (both P < 0.01. In multivariate models, IAS fat thickness remained independently associated with larger LA volumes, increased LA kinetic energy and ejection force (β-coef: 0.17 & 0.15, both P < 0.05, and impaired LA reservoir and conduit function (β-coef: −0.20 & −0.12, both P < 0.05 after adjusting for clinical variables. Conclusion: Accumulated visceral adiposity, especially interatrial fat depots, was associated with certain LA structural/functional remodeling characterized by impaired LA reservoir and conduit function though augmented kinetic energy and ejection performance. Our data suggested that interatrial fat burden may be associated with certain detrimental LA functions with compensatory LA adaptation in an asymptomatic population.

  10. Beat-to-beat assessment of left ventricular ejection in atrial fibrillation

    Energy Technology Data Exchange (ETDEWEB)

    Benjelloun, H; Brochier, M; Itti, R; Philippe, L; Lorgeron, J M

    1983-05-01

    Beat-to-beat left ventricular ejection was evaluated in a group of 20 patients with chronic atrial fibrillation using a computerized single probe detector. The reference group consisted of 10 patients with sinus rhythm. For each patient 30 successive cardiac cycles were analyzed and the relative variations of four parameters were assessed: R-R interval, diastolic and systolic time intervals, and ejection amplitude, corresponding to the left ventricular stroke volume. The mean variations were respectively 3.4%, 10.4%, 8.4%, and 11.8% in patients with sinus rhythm, and 21.9%, 37.9%, 10.6% and 30.5% in patients with artrial fibrillation. This demonstrates that changes in ejection are mainly related to the duration of the filling phase, with nearly constant systolic times. Correlations between R-R intervals and systolic ejection amplitudes were highly significant (P<0.001) in patients with atrial fibrillation in 85% of cases. This information complements the average ejection fraction obtained from multiple cycle superimposition.

  11. Left atrial appendages from adult hearts contain a reservoir of diverse cardiac progenitor cells.

    Directory of Open Access Journals (Sweden)

    Jussi V Leinonen

    Full Text Available There is strong evidence supporting the claim that endogenous cardiac progenitor cells (CPCs are key players in cardiac regeneration, but the anatomic source and phenotype of the master cardiac progenitors remains uncertain. Our aim was to investigate the different cardiac stem cell populations in the left atrial appendage (LAA and their fates.We investigated the CPC content and profile of adult murine LAAs using immunohistochemistry and flow cytometry. We demonstrate that the LAA contains a large number of CPCs relative to other areas of the heart, representing over 20% of the total cell number. We grew two distinct CPC populations from the LAA by varying the degree of proteolysis. These differed by their histological location, surface marker profiles and growth dynamics. Specifically, CD45(pos cells grew with milder proteolysis, while CD45(neg cells grew mainly with more intense proteolysis. Both cell types could be induced to differentiate into cells with cardiomyocyte markers and organelles, albeit by different protocols. Many CD45(pos cells expressed CD45 initially and rapidly lost its expression while differentiating.Our results demonstrate that the left atrial appendage plays a role as a reservoir of multiple types of progenitor cells in murine adult hearts. Two different types of CPCs were isolated, differing in their epicardial-myocardial localization. Considering studies demonstrating layer-specific origins of different cardiac progenitor cells, our findings may shed light on possible pathways to study and utilize the diversity of endogenous progenitor cells in the adult heart.

  12. Beat-to-beat assessment of left ventricular ejection in atrial fibrillation

    International Nuclear Information System (INIS)

    Benjelloun, H.; Brochier, M.; Itti, R.; Philippe, L.; Lorgeron, J.M.

    1983-01-01

    Beat-to-beat left ventricular ejection was evaluated in a group of 20 patients with chronic atrial fibrillation using a computerized single probe detector. The reference group consisted of 10 patients with sinus rhythm. For each patient 30 successive cardiac cycles were analyzed and the relative variations of four parameters were assessed: R-R interval, diastolic and systolic time intervals, and ejection amplitude, corresponding to the left ventricular stroke volume. The mean variations were respectively 3.4%, 10.4%, 8.4%, and 11.8% in patients with sinus rhythm, and 21.9%, 37.9%, 10.6% and 30.5% in patients with artrial fibrillation. This demonstrates that changes in ejection are mainly related to the duration of the filling phase, with nearly constant systolic times. Correlations between R-R intervals and systolic ejection amplitudes were highly significant (P<0.001) in patients with atrial fibrillation in 85% of cases. This information complements the average ejection fraction obtained from multiple cycle superimposition. (orig.)

  13. Rationale and Design of the Reduce Elevated Left Atrial Pressure in Patients With Heart Failure (Reduce LAP-HF) Trial

    DEFF Research Database (Denmark)

    Hasenfuss, Gerd; Gustafsson, Finn; Kaye, David

    2015-01-01

    OBJECTIVE: Heart failure with preserved ejection fraction (HFpEF) is characterized by elevated left atrial pressure during rest and/or exercise. The Reduce LAP-HF (Reduce Elevated Left Atrial Pressure in Patients With Heart Failure) trial will evaluate the safety and performance of the Interatrial...... Shunt Device (IASD) System II, designed to directly reduce elevated left atrial pressure, in patients with HFpEF. METHODS: The Reduce LAP-HF Trial is a prospective, nonrandomized, open-label trial to evaluate a novel device that creates a small permanent shunt at the level of the atria. A minimum of 60...... patients with ejection fraction ≥40% and New York Heart Association functional class III or IV heart failure with a pulmonary capillary wedge pressure (PCWP) ≥15 mm Hg at rest or ≥25 mm Hg during supine bike exercise will be implanted with an IASD System II, and followed for 6 months to assess the primary...

  14. Left atrial enlargement increases the risk of major adverse cardiac events independent of coronary vasodilator capacity

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Angela S. [Brigham and Women' s Hospital, Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Boston, MA (United States); National Heart Centre Singapore, Singapore (Singapore); Murthy, Venkatesh L.; Sitek, Arkadiusz; Gayed, Peter; Bruyere, John; Di Carli, Marcelo F. [Brigham and Women' s Hospital, Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Boston, MA (United States); Wu, Justina [Brigham and Women' s Hospital, Division of Cardiology, Department of Medicine, and the Noninvasive Cardiovascular Imaging Program, Departments of Medicine (Cardiology) and Radiology, Boston, MA (United States); Dorbala, Sharmila [Brigham and Women' s Hospital, Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Boston, MA (United States); Brigham and Women' s Hospital, Department of Radiology and the Division of Cardiology, Noninvasive Cardiovascular Imaging Section, Boston, MA (United States)

    2015-09-15

    Longstanding uncontrolled atherogenic risk factors may contribute to left atrial (LA) hypertension, LA enlargement (LAE) and coronary vascular dysfunction. Together they may better identify risk of major adverse cardiac events (MACE). The aim of this study was to test the hypothesis that chronic LA hypertension as assessed by LAE modifies the relationship between coronary vascular function and MACE. In 508 unselected subjects with a normal clinical {sup 82}Rb PET/CT, ejection fraction ≥40 %, no prior coronary artery disease, valve disease or atrial fibrillation, LAE was determined based on LA volumes estimated from the hybrid perfusion and CT transmission scan images and indexed to body surface area. Absolute myocardial blood flow and global coronary flow reserve (CFR) were calculated. Subjects were systematically followed-up for the primary end-point - MACE - a composite of all-cause death, myocardial infarction, hospitalization for heart failure, stroke, coronary artery disease progression or revascularization. During a median follow-up of 862 days, 65 of the subjects experienced a composite event. Compared with subjects with normal LA size, subjects with LAE showed significantly lower CFR (2.25 ± 0.83 vs. 1.95 ± 0.80, p = 0.01). LAE independently and incrementally predicted MACE even after accounting for clinical risk factors, medication use, stress left ventricular ejection fraction, stress left ventricular end-diastolic volume index and CFR (chi-squared statistic increased from 30.9 to 48.3; p = 0.001). Among subjects with normal CFR, those with LAE had significantly worse event-free survival (risk adjusted HR 5.4, 95 % CI 2.3 - 12.8, p < 0.0001). LAE and reduced CFR are related but distinct cardiovascular adaptations to atherogenic risk factors. LAE is a risk marker for MACE independent of clinical factors and left ventricular volumes; individuals with LAE may be at risk of MACE despite normal coronary vascular function. (orig.)

  15. Atrial Fibrillation associated chromosome 4q25 variants are not associated with PITX2c expression in human adult left atrial appendages.

    Directory of Open Access Journals (Sweden)

    Shamone R Gore-Panter

    Full Text Available Atrial Fibrillation (AF, the most common sustained arrhythmia, has a strong genetic component, but the mechanism by which common genetic variants lead to increased AF susceptibility is unknown. Genome-wide association studies (GWAS have identified that the single nucleotide polymorphisms (SNPs most strongly associated with AF are located on chromosome 4q25 in an intergenic region distal to the PITX2 gene. Our objective was to determine whether the AF-associated SNPs on chromosome 4q25 were associated with PITX2c expression in adult human left atrial appendages. Analysis of a lone AF GWAS identified four independent AF risk SNPs at chromosome 4q25. Human adult left atrial appendage tissue was obtained from 239 subjects of European Ancestry and used for SNP analysis of genomic DNA and determination of PITX2c RNA expression levels by quantitative PCR. Subjects were divided into three groups based on their history of AF and pre-operative rhythm. AF rhythm subjects had higher PITX2c expression than those with history of AF but in sinus rhythm. PITX2c expression was not associated with the AF risk SNPs in human adult left atrial appendages in all subjects combined or in each of the three subgroups. However, we identified seven SNPs modestly associated with PITX2c expression located in the introns of the ENPEP gene, ∼54 kb proximal to PITX2. PITX2c expression in human adult left atrial appendages is not associated with the chromosome 4q25 AF risk SNPs; thus, the mechanism by which these SNPs are associated with AF remains enigmatic.

  16. Left Atrial Appendage Closure Device With Delivery System: A Health Technology Assessment

    Science.gov (United States)

    Nevis, Immaculate; Falk, Lindsey; Wells, David; Higgins, Caroline

    2017-01-01

    Background Atrial fibrillation is a common cardiac arrhythmia, and 15% to 20% of those who have experienced stroke have atrial fibrillation. Treatment options to prevent stroke in people with atrial fibrillation include pharmacological agents such as novel oral anticoagulants or nonpharmacological devices such as the left atrial appendage closure device with delivery system (LAAC device). The objectives of this health technology assessment were to assess the clinical effectiveness and cost-effectiveness of the LAAC device versus novel oral anticoagulants in patients without contraindications to oral anticoagulants and versus antiplatelet agents in patients with contraindications to oral anticoagulants. Methods We performed a systematic review and network meta-analysis. We also conducted an economic literature review, economic evaluation, and budget impact analysis to assess the cost-effectiveness and budget impact of the LAAC device compared with novel oral anticoagulants and oral antiplatelet agents (e.g., aspirin). We also spoke with patients to better understand their preferences, perspectives, and values. Results Seven randomized controlled studies met the inclusion criteria for indirect comparison. Five studies assessed the effectiveness of novel oral anticoagulants versus warfarin, and two studies compared the LAAC device with warfarin. No studies were identified that compared the LAAC device with aspirin in patients in whom oral anticoagulants were contraindicated. Using the random effects model, we found that the LAAC device was comparable to novel oral anticoagulants in reducing stroke (odds ratio [OR] 0.85; credible interval [Cr.I] 0.63–1.05). Similarly, the reduction in the risk of all-cause mortality was comparable between the LAAC device and novel oral anticoagulants (OR 0.71; Cr.I 0.49–1.22). The LAAC device was found to be superior to novel oral anticoagulants in preventing hemorrhagic stroke (OR 0.45; Cr.I 0.29–0.79), whereas novel oral

  17. The influence of right ventricular apical pacing on left atrial volume in patients with normal left ventricular function

    Directory of Open Access Journals (Sweden)

    AR Moaref1

    2008-03-01

    Full Text Available Background: Right ventricular apical (RVA pacing has been reported to induce several deleterious effects particularly in the presence of structural heart disease but can also involve patients with normal left ventricular (LV function. Left atrial (LA enlargement is one of these effects, but the majority of studies have measured LA dimension rather than volume.Objective: The present prospective study was designed to assess the effect of RVA pacing on LA volume in patients with normal LV function.Patients and Methods: The study comprised 41 consecutive patients with LV ejection fraction ≥ 45% and LV end diastolic dimension ≤ 56 mm who underwent single-or dual- chamber pacemaker implantation in RVA and followed for LA volume measurement and pacemaker analysis at least during the ensuing 4.2 months. Results: In all, 21 patients were excluded from the study due to five spontaneous wide QRS complex (≥120msec, one recent acute coronary syndrome,one significant valvular heart disease, three pacing frequency <90%, eight death or losing follow up in three cases. In remaining 20 patients, LA volume ragned from 21 to 54 mm3 with mean of 37.3±9.7 mm3 prior to pacemaker implantation that increased to 31 to 103 mm3 (54.3±17.0 during follow-up (P<0.001.Conclusion: RVA pacing might lead to an increase in LA volume even in patients with normal LV function.

  18. Brain Abscess Associated with Isolated Left Superior Vena Cava Draining into the Left Atrium in the Absence of Coronary Sinus and Atrial Septal Defect

    International Nuclear Information System (INIS)

    Erol, Ilknur; Cetin, I. Ilker; Alehan, Fuesun; Varan, Birguel; Ozkan, Sueleyman; Agildere, A. Muhtesem; Tokel, Kursad

    2006-01-01

    A previously healthy 12-year-old girl presented with severe headache for 2 weeks. On physical examination, there was finger clubbing without apparent cyanosis. Neurological examination revealed only papiledema without focal neurologic signs. Cerebral magnetic resonance imaging showed the characteristic features of brain abscess in the left frontal lobe. Cardiologic workup to exclude a right-to-left shunt showed an abnormality of the systemic venous drainage: presence of isolated left superior vena cava draining into the left atrium in the absence of coronary sinus and atrial septal defect. This anomaly is rare, because only a few other cases have been reported

  19. Computational fluid dynamics modelling of left valvular heart diseases during atrial fibrillation

    Directory of Open Access Journals (Sweden)

    Stefania Scarsoglio

    2016-07-01

    Full Text Available Background: Although atrial fibrillation (AF, a common arrhythmia, frequently presents in patients with underlying valvular disease, its hemodynamic contributions are not fully understood. The present work aimed to computationally study how physical conditions imposed by pathologic valvular anatomy act on AF hemodynamics. Methods: We simulated AF with different severity grades of left-sided valvular diseases and compared the cardiovascular effects that they exert during AF, compared to lone AF. The fluid dynamics model used here has been recently validated for lone AF and relies on a lumped parameterization of the four heart chambers, together with the systemic and pulmonary circulation. The AF modelling involves: (i irregular, uncorrelated and faster heart rate; (ii atrial contractility dysfunction. Three different grades of severity (mild, moderate, severe were analyzed for each of the four valvulopathies (AS, aortic stenosis, MS, mitral stenosis, AR, aortic regurgitation, MR, mitral regurgitation, by varying–through the valve opening angle–the valve area. Results: Regurgitation was hemodynamically more relevant than stenosis, as the latter led to inefficient cardiac flow, while the former introduced more drastic fluid dynamics variation. Moreover, mitral valvulopathies were more significant than aortic ones. In case of aortic valve diseases, proper mitral functioning damps out changes at atrial and pulmonary levels. In the case of mitral valvulopathy, the mitral valve lost its regulating capability, thus hemodynamic variations almost equally affected regions upstream and downstream of the valve. In particular, the present study revealed that both mitral and aortic regurgitation strongly affect hemodynamics, followed by mitral stenosis, while aortic stenosis has the least impact among the analyzed valvular diseases. Discussion: The proposed approach can provide new mechanistic insights as to which valvular pathologies merit more aggressive

  20. Computational Fluid Dynamic Analysis of the Left Atrial Appendage to Predict Thrombosis Risk

    Directory of Open Access Journals (Sweden)

    Giorgia Maria Bosi

    2018-04-01

    Full Text Available During Atrial Fibrillation (AF more than 90% of the left atrial thrombi responsible for thromboembolic events originate in the left atrial appendage (LAA, a complex small sac protruding from the left atrium (LA. Current available treatments to prevent thromboembolic events are oral anticoagulation, surgical LAA exclusion, or percutaneous LAA occlusion. However, the mechanism behind thrombus formation in the LAA is poorly understood. The aim of this work is to analyse the hemodynamic behaviour in four typical LAA morphologies - “Chicken wing”, “Cactus”, “Windsock” and “Cauliflower” - to identify potential relationships between the different shapes and the risk of thrombotic events. Computerised tomography (CT images from four patients with no LA pathology were segmented to derive the 3D anatomical shape of LAA and LA. Computational Fluid Dynamic (CFD analyses based on the patient-specific anatomies were carried out imposing both healthy and AF flow conditions. Velocity and shear strain rate (SSR were analysed for all cases. Residence time in the different LAA regions was estimated with a virtual contrast agent washing out. CFD results indicate that both velocity and SSR decrease along the LAA, from the ostium to the tip, at each instant in the cardiac cycle, thus making the LAA tip more prone to fluid stagnation, and therefore to thrombus formation. Velocity and SSR also decrease from normal to AF conditions. After four cardiac cycles, the lowest washout of contrast agent was observed for the Cauliflower morphology (3.27% of residual contrast in AF, and the highest for the Windsock (0.56% of residual contrast in AF. This suggests that the former is expected to be associated with a higher risk of thrombosis, in agreement with clinical reports in the literature. The presented computational models highlight the major role played by the LAA morphology on the hemodynamics, both in normal and AF conditions, revealing the potential

  1. Electron-beam computed tomography findings of left atrial appendage in patients with cardiogenic cerebral embolism

    Energy Technology Data Exchange (ETDEWEB)

    Okamoto, Makiko; Takahashi, Satoshi; Yonezawa, Hisashi [Iwate Medical Univ., Morioka (Japan). School of Medicine

    2002-04-01

    We studied electron-beam computed tomography (EBCT) findings in the left atrial appendage of 72 patients with cerebral embolism [27 in the acute phase (<48 hours) and 45 in the chronic phase], 9 cases with nonvalvular atrial fibrillation (NVAF) but without stroke, and 13 controls. EBCT was performed in the early (during injection of contrast medium), late-1 (5 min after injection), and-2 (10 min after injection) phases. In the acute phase patients, 41% showed filling defect (FD) in the early phase alone (FDE), 15% showed FD until late phase-1 (FDL-1), and 15% showed FD until late phase-2 (FDL-2). The chronic phase patients showed FDE in 33% of cases, FDL-1 in 8% and FDL-2 11%. Only FDE was observed in 44% in NVAF cases without stroke. No FDs were observed in controls. Flow velocity in the appendage measured by transesophageal echocardiography was 23{+-}10 cm/sec in 21 FDE cases, 14{+-}3 cm/sec in 3 FDL-1 cases, 29{+-}23 cm/sec in 4 FDL-2 cases, significantly lower in comparison with 58{+-}25 cm/s in the 23 cases with no FD. FDL-1 and -2 suggested severe stasis or presence of thrombus in the appendage, which indicated high risk of embolism slower the movement of MES through the sample volume. (author)

  2. Electron-beam computed tomography findings of left atrial appendage in patients with cardiogenic cerebral embolism

    International Nuclear Information System (INIS)

    Okamoto, Makiko; Takahashi, Satoshi; Yonezawa, Hisashi

    2002-01-01

    We studied electron-beam computed tomography (EBCT) findings in the left atrial appendage of 72 patients with cerebral embolism [27 in the acute phase (<48 hours) and 45 in the chronic phase], 9 cases with nonvalvular atrial fibrillation (NVAF) but without stroke, and 13 controls. EBCT was performed in the early (during injection of contrast medium), late-1 (5 min after injection), and-2 (10 min after injection) phases. In the acute phase patients, 41% showed filling defect (FD) in the early phase alone (FDE), 15% showed FD until late phase-1 (FDL-1), and 15% showed FD until late phase-2 (FDL-2). The chronic phase patients showed FDE in 33% of cases, FDL-1 in 8% and FDL-2 11%. Only FDE was observed in 44% in NVAF cases without stroke. No FDs were observed in controls. Flow velocity in the appendage measured by transesophageal echocardiography was 23±10 cm/sec in 21 FDE cases, 14±3 cm/sec in 3 FDL-1 cases, 29±23 cm/sec in 4 FDL-2 cases, significantly lower in comparison with 58±25 cm/s in the 23 cases with no FD. FDL-1 and -2 suggested severe stasis or presence of thrombus in the appendage, which indicated high risk of embolism slower the movement of MES through the sample volume. (author)

  3. ST-segment elevation and ventricular fibrillation shortly after transseptal puncture for left atrial catheter ablation

    Directory of Open Access Journals (Sweden)

    Daisuke Ishigaki, MD

    2013-10-01

    Full Text Available A 47-year-old man with drug-resistant paroxysmal atrial fibrillation underwent left atrial (LA catheter ablation. After sheaths were inserted into the LA using the Brockenbrough method, he complained of angina and developed ST-segment elevation in the II, III, aVF, V5, and V6 leads. Ventricular fibrillation (VF occurred followed by ventricular tachycardia. The VF was successfully treated with direct current shock. Coronary angiography with isosorbide dinitrate showed neither spasm nor embolism in the coronary artery. The chest pain disappeared after 6 min with resolution of the ST-segment elevation. A summarized review of ST-segment elevation associated with transseptal puncture disclosed that ST-segment elevation is often found in inferior leads (87.5%, while concomitant bradyarrhythmia has been reported in 43.8% of patients. Our patient is the first recorded case with potentially lethal tachyarrhythmia. Although ST-segment elevation and VF is a rare complication associated with transseptal puncture, awareness of this complication is important.

  4. A novel device for the occlusion of left atrial appendage: an experimental study in canine models

    International Nuclear Information System (INIS)

    Yang Zhihong; Qin Yongwen; Wu Hong; Hu Jianqiang; Wang Shengqiang; Ding Zhongru; Liu Zongjun

    2011-01-01

    Objective: To evaluate the feasibility, safety and biocompatibility of a novel device designed by the authors for the occlusion of left atrial appendage (LAA) in canine models. Methods: The occlusion of LAA was performed in 20 experimental dogs by using a novel LAA occluder, which was delivered to the LAA through a transseptal catheter. During the period of 2 weeks to 6 months after the procedure, the dogs were kept under observation for the device healing, migration, perforation and the formation of thrombus. Both scanning electron microscope (SEM) and transmission electron microscope (TEM) were used to examine the endothelial growth on the surface of the occluder and the structure of the endothelial cells. Results: Of the total 20 dogs, the novel device was successfully implanted in 14. The LAA was occluded completely in 13 dogs. No mobile thrombi caused by the implantation procedure were observed. Endothelialization of the atrium-facing surface was observed at one month after the procedure, and the surface was completely covered with endothelial cells at 3 months after the treatment, which was confirmed by gross, histological and SEM examinations. TEM examination showed that the structure of endothelial cells, the mitochondrion and sarcomere of atrial cardiocyte were all normal. Gross and light microscopic examination of the kidney, lung spleen and liver showed that there was no evidence of embolism or infarction. Conclusion: The novel device is safe and feasible for the occlusion of the LAA in experimental dogs. Further study is needed to observe its long-term safety. (authors)

  5. Velocity encoded cardiovascular magnetic resonance to assess left atrial appendage emptying

    Directory of Open Access Journals (Sweden)

    Muellerleile Kai

    2012-06-01

    Full Text Available Abstract Background The presence of impaired left atrial appendage (LAA function identifies patients who are prone to thrombus formation in the LAA and therefore being at high risk for subsequent cardioembolic stroke. LAA function is typically assessed by measurements of LAA emptying velocities using transesophageal echocardiography (TEE in clinical routine. This study aimed at evaluating the feasibility of assessing LAA emptying by velocity encoded (VENC cardiovascular magnetic resonance (CMR. Methods This study included 30 patients with sinus rhythm (n = 18 or atrial fibrillation (n = 12. VENC-CMR velocity measurements were performed perpendicular to the orifice of the LAA. Peak velocities were measured of passive diastolic LAA emptying (e-wave in all patients. Peak velocities of active, late-diastolic LAA emptying (a-wave were assessed in patients with sinus rhythm. Correlation and agreement was analyzed between VENC-CMR and TEE measurements of e- and a-wave peak velocities. Results A significant correlation and good agreement was found between VENC-CMR and TEE measurements of maximal e-wave velocities (r = 0.61, P  Conclusions The assessment of active and passive LAA emptying by VENC-CMR is feasible. Further evaluation is required of potential future clinical applications such as risk stratification for cardioembolic stroke.

  6. Left atrial volume and function in dogs with naturally occurring myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Höllmer, M.; Willesen, J. L.; Tolver, A.

    2017-01-01

    stroke volume increased, whereas LA reservoir and contractile function decreased with increasing disease severity. A maximal LA volume heart failure in dogs with chronic MMVD with a sensitivity of 96% and a specificity of 100......%. An active LA emptying fraction heart failure in dogs with chronic MMVD with a sensitivity of 77% and a specificity of 89% and a sensitivity of 82% and a specificity of 82%, respectively. CONCLUSION: Dogs with MMVD appear to have larger LA...... of cardiac compensation. Left atrial function in dogs with naturally occurring MMVD remains largely unexplored. The objective of this study was to evaluate LA volume and function in dogs with naturally occurring MMVD. ANIMALS: This prospective study included 205 client-owned dogs of different breeds, 114...

  7. Left Ventricular Systolic Function Assessed by Global Longitudinal Strain is Impaired in Atrial Fibrillation Compared to Sinus Rhythm

    DEFF Research Database (Denmark)

    Agner, Bue Fridolin Ross; Katz, Michael G; Williams, Zachary R

    2018-01-01

    Background: Atrial fibrillation (AF) is the most common aberrant cardiac arrhythmia. Many AF patients present with symptoms of dyspnea and fatigue, but have normal left ventricular ejection fraction (LVEF). Purpose: To determine the reproducibility of measurements of global longitudinal strain (GLS...

  8. Increased pulse pressure is associated with left atrial enlargement in resistant hypertensive patients.

    Science.gov (United States)

    Armario, Pedro; Oliveras, Anna; Hernández-Del-Rey, Raquel; Suárez, Carmen; Martell, Nieves; Ruilope, Luis M; De La Sierra, Alejandro

    2013-02-01

    Resistant hypertension (RH) is frequently associated with a high prevalence of target organ damage, which impairs the prognosis of these patients. Considering cardiac alterations in RH, most attention has been devoted to left ventricular hypertrophy (LVH), but data concerning left atrial enlargement (LAE) is less known. This cross-sectional study assessed the factors associated with LAE, with special focus on blood pressure (BP) estimates obtained by ambulatory blood pressure monitoring (ABPM), in 250 patients with RH, aged 64 ± 11 years. LAE and LVH were observed in 10.0% (95% CI 6.3-13.7) and 57.1% (95% CI 50.8-63.5) of patients, respectively. Compared with patients with normal atrium size, those exhibiting LAE were older, more frequently women, had elevated pulse pressure (PP) measured both at the office and by ABPM, and showed higher prevalence of LVH (83% vs 54%; p = 0.016). In a logistic regression analysis, adjusting for age, gender, body mass index, left ventricular mass index and BP pressure estimates, night-time PP was independently associated with LAE (OR for 5 mmHg = 1.28, 95% CI 1.24-1.32; p = 0.001). In conclusion, besides classical determinants of LAE, such as age and LVH, an elevated night-time PP was independently associated with LAE in patients with RH.

  9. Relationship of carotid arterial functional and structural changes to left atrial volume in untreated hypertension.

    Science.gov (United States)

    Jaroch, Joanna; Rzyczkowska, Barbara; Bociąga, Zbigniew; Vriz, Olga; Driussi, Caterina; Loboz-Rudnicka, Maria; Dudek, Krzysztof; Łoboz-Grudzień, Krystyna

    2016-04-01

    The contribution of arterial functional and structural changes to left ventricular (LV) diastolic dysfunction has been the area of recent research. There are some studies on the relationship between arterial stiffness (a.s.) and left atrial (LA) remodelling as a marker of diastolic burden. Little is known about the association of arterial structural changes and LA remodelling in hypertension (H). The aim of this study was to examine the relationship between carotid a.s. and intima-media thickness (IMT) and LA volume in subjects with H. The study included 245 previously untreated hypertensives (166 women and 79 men, mean age 53.7 ± 11.8 years). Each patient was subjected to echocardiography with measurement of LA volume, evaluation of left ventricular hypertrophy (LVH) and LV systolic/diastolic function indices, integrated assessment of carotid IMT and echo-tracking of a.s. and wave reflection parameters. Univariate regression analysis revealed significant correlations between indexed LA volume and selected clinical characteristics, echocardiographic indices of LVH and LV diastolic/systolic function and a.s./wave reflection parameters. The following parameters were identified as independent determinants of indexed LA volume on multivariate regression analysis: diastolic blood pressure (beta = -0.229, P arterial stiffness but not intima-media thickness and LA volume in patients with untreated hypertension.

  10. Left atrial volume assessment in atrial fibrillation using multimodality imaging: a comparison of echocardiography, invasive three-dimensional CARTO and cardiac magnetic resonance imaging.

    Science.gov (United States)

    Rabbat, Mark G; Wilber, David; Thomas, Kevin; Malick, Owais; Bashir, Atif; Agrawal, Anoop; Biswas, Santanu; Sanagala, Thriveni; Syed, Mushabbar A

    2015-06-01

    Left atrial size in atrial fibrillation is a strong predictor of successful ablation and cardiovascular events. Cardiac magnetic resonance multislice method (CMR-MSM) is the current gold standard for left atrial volume (LAV) assessment but is time consuming. We investigated whether LAV with more rapid area-length method by echocardiography (Echo-AL) or cardiac magnetic resonance (CMR-AL) and invasive measurement by 3D-CARTO mapping during ablation correlate with the CMR-MSM. We studied 250 consecutive patients prior to atrial fibrillation ablation. CMR images were acquired on 3T scanner to measure LAV by MSM and biplane area-length method. Standard echocardiography views were used to calculate LAV by biplane area-length method. LAV during ablation was measured by 3D-CARTO mapping. LAV was compared using intra-class correlation (ICC), Pearson's correlation and Bland-Altman plots. CMR-MSM was used as the reference standard. Mean LAV using CMR-MSM was 112.7 ± 36.7 ml. CMR-AL method overestimated LAV by 13.3 ± 21.8 ml (11.2%, p atrial fibrillation. CMR-AL and 3D-CARTO correlated and agreed well with CMR-MSM (r = 0.87 and 0.74, ICC = 0.80 and 0.77 respectively). However, Echo-AL had poor correlation and agreement with CMR-MSM (r = 0.66 and ICC = 0.48). Bland-Altman plots confirmed these findings. CMR-AL method may be used as an alternative to CMR-MSM, as it is non-invasive, rapid, and correlates well with CMR-MSM. LAV by different modalities should not be used interchangeably.

  11. Left atrial enlargement increases the risk of major adverse cardiac events independent of coronary vasodilator capacity.

    Science.gov (United States)

    Koh, Angela S; Murthy, Venkatesh L; Sitek, Arkadiusz; Gayed, Peter; Bruyere, John; Wu, Justina; Di Carli, Marcelo F; Dorbala, Sharmila

    2015-09-01

    Longstanding uncontrolled atherogenic risk factors may contribute to left atrial (LA) hypertension, LA enlargement (LAE) and coronary vascular dysfunction. Together they may better identify risk of major adverse cardiac events (MACE). The aim of this study was to test the hypothesis that chronic LA hypertension as assessed by LAE modifies the relationship between coronary vascular function and MACE. In 508 unselected subjects with a normal clinical (82)Rb PET/CT, ejection fraction ≥40 %, no prior coronary artery disease, valve disease or atrial fibrillation, LAE was determined based on LA volumes estimated from the hybrid perfusion and CT transmission scan images and indexed to body surface area. Absolute myocardial blood flow and global coronary flow reserve (CFR) were calculated. Subjects were systematically followed-up for the primary end-point - MACE - a composite of all-cause death, myocardial infarction, hospitalization for heart failure, stroke, coronary artery disease progression or revascularization. During a median follow-up of 862 days, 65 of the subjects experienced a composite event. Compared with subjects with normal LA size, subjects with LAE showed significantly lower CFR (2.25 ± 0.83 vs. 1.95 ± 0.80, p = 0.01). LAE independently and incrementally predicted MACE even after accounting for clinical risk factors, medication use, stress left ventricular ejection fraction, stress left ventricular end-diastolic volume index and CFR (chi-squared statistic increased from 30.9 to 48.3; p = 0.001). Among subjects with normal CFR, those with LAE had significantly worse event-free survival (risk adjusted HR 5.4, 95 % CI 2.3 - 12.8, p < 0.0001). LAE and reduced CFR are related but distinct cardiovascular adaptations to atherogenic risk factors. LAE is a risk marker for MACE independent of clinical factors and left ventricular volumes; individuals with LAE may be at risk of MACE despite normal coronary vascular function.

  12. Assessment of left atrial volume and function: a comparative study between echocardiography, magnetic resonance imaging and multi slice computed tomography.

    Science.gov (United States)

    Kühl, J Tobias; Lønborg, Jacob; Fuchs, Andreas; Andersen, Mads J; Vejlstrup, Niels; Kelbæk, Henning; Engstrøm, Thomas; Møller, Jacob E; Kofoed, Klaus F

    2012-06-01

    Measurement of left atrial (LA) maximal volume (LA(max)) using two-dimensional transthoracic echocardiography (TTE) provides prognostic information in several cardiac diseases. However, the relationship between LA(max) and LA function is poorly understood and TTE is less well suited for measuring dynamic LA volume changes. Conversely, cardiac magnetic resonance imaging (CMR) and multi-slice computed tomography (MSCT) appears more appropriate for such measures. We sought to determine the relationship between LA size assessed with TTE and LA size and function assessed with CMR and MSCT. Fifty-four patients were examined 3 months post myocardial infarction with echocardiography, CMR and MSCT. Left atrial volumes and LA reservoir function were assessed by TTE. LA time-volume curves were determined and LA reservoir function (cyclic change and fractional change), passive emptying function (reservoir volume) and pump function (left atrial ejection fraction-LAEF) were derived using CMR and MSCT. Left atrial fractional change and left atrial ejection fraction (LAEF) determined with CMR and MSCT were unrelated to LA(max) enlargement by echocardiography (P = NS). There was an overall good agreement between CMR and MSCT, with a small to moderate bias in LA(max) (4.9 ± 10.4 ml), CC (3.1 ± 9.1 ml) and reservoir volume (3.4 ± 9.1 ml). TTE underestimates LA(max) with up to 32% compared with CMR and MSCT (P fractional change and LAEF is not significantly related to LA(max) measured by TTE. TTE systematically underestimated LA volumes, whereas there are good agreements between MSCT and CMR for volumetric and functional properties.

  13. Left atrial appendage occlusion with Amplatzer Cardio Plug is an acceptable therapeutic option for prevention of stroke recurrence in patients with non-valvular atrial fibrillation and contraindication or failure of oral anticoagulation with acenocumarol

    OpenAIRE

    Hawkes, Maximiliano A.; Pertierra, Lucía; Rodriguez-Lucci, Federico; Pujol-Lereis, Virginia A.; Ameriso, Sebastián F.

    2016-01-01

    ABSTRACT Left atrial appendage occlusion (LAAO) appears as a therapeutic option for some atrial fibrillation patients not suitable for oral anticoagulation because an increased hemorrhagic risk or recurrent ischemic events despite anticoagulant treatment. Methods Report of consecutive atrial fibrillation patients treated with LAAO with Amplatzer Cardio Plug because contraindication or failure of oral anticoagulation with acenocumarol. CHA2DS2VASC, HAS-BLED, NIHSS, mRS, procedural complicati...

  14. Characteristics of Left Atrial Deformation Parameters and Their Prognostic Impact in Patients with Pathological Left Ventricular Hypertrophy: Analysis by Speckle Tracking Echocardiography.

    Science.gov (United States)

    Iio, Chiharuko; Inoue, Katsuji; Nishimura, Kazuhisa; Fujii, Akira; Nagai, Takayuki; Suzuki, Jun; Okura, Takafumi; Higaki, Jitsuo; Ogimoto, Akiyoshi

    2015-12-01

    The pathological process of left ventricular (LV) hypertrophy is associated with left atrial (LA) remodeling. This study was aimed to evaluate the prognostic value of LA strain parameters in patients with pathological LV hypertrophy. This study included 95 patients with hypertensive heart disease (HHD: n = 24), hypertrophic cardiomyopathy (HCM: n = 56), cardiac amyloidosis (CA: n = 15), and control subjects (n = 20). We used two-dimensional speckle tracking echocardiography (STE) to analyze LA global strain. LA electromechanical conduction time (EMT) at the septal (EMT-septal) and lateral wall (EMT-lateral), and their time difference (EMT-diff) were calculated. The incidence of cardiac death and heart failure hospitalization was defined as major cardiac events and that of atrial fibrillation as secondary outcome. Left atrial volume index was increased and LA booster strain was decreased in the HCM and CA groups compared with the HHD group. EMT-lateral was increased in the diseased groups compared with the control. EMT-diff was prolonged in the CA group compared with the HCM group. During the follow-up period (mean 3.4 years), major cardiac events and atrial fibrillation occurred in 17 and 13 patients, respectively. The occurrence of atrial fibrillation was associated with CA etiology, E/e', LA volume index, LAa, and EMT-lateral. The incidence of major cardiac events was independently correlated with LA volume index and EMT-diff in multivariate analysis. This study suggested that the EMT-diff could discriminate patients with a high risk of cardiac events among patients with pathological LV hypertrophy. © 2015, Wiley Periodicals, Inc.

  15. A Left Atrial Myxoma Case with a History of Stroke on whom a Coronary Bypass Surgery was Performed

    Directory of Open Access Journals (Sweden)

    Cihangir Kaymaz

    2009-12-01

    Full Text Available Cardiac myxomas are the most frequently encountered benign cardiac tumors in adult groups. Patients with myxoma may suffer from variety of clinical features. A patient who had suffered from stroke a yearago came to our hospital with a chest pain complaint. In the echocardiography of the patient suffering from acute coronary syndrome, left ventricular disfunction and left atrial mass was determined. In the coronary angiography, LAD and Cx critical stenosis, and an abnormal feeding artery which roots from Cxperformed was observed. LIMA-AD, Ao-RCA bypass and mass exision withleft atriotomy was made. Cardiac tumor embolism which makes up a rare cause of cerebral embolies should be considered especiallyin patients with sinus rhythm. In the coronary angiography the feeding artery of the myxoma was shown. A patient who has underwent coronary bypass operation and left atrial myxoma exision has beenpresented as a case.

  16. Evolution from electrophysiologic to hemodynamic monitoring: the story of left atrial and pulmonary artery pressure monitors

    Directory of Open Access Journals (Sweden)

    Deirdre M Mooney

    2015-10-01

    Full Text Available Heart failure (HF is a costly, challenging and highly prevalent medical condition. Hospitalization for acute decompensation is associated with high morbidity and mortality. Despite application of evidence-based medical therapies and technologies, HF remains a formidable challenge for virtually all healthcare systems. Repeat hospitalizations for acute decompensated HF (ADHF can have major financial impact on institutions and resources. Early and accurate identification of impending ADHF is of paramount importance yet there is limited high quality evidence or infrastructure to guide management in the outpatient setting. Historically, ADHF was identified by physical exam findings or invasive hemodynamic monitoring during a hospital admission; however, advances in medical microelectronics and the advent of device-based diagnostics have enabled long-term ambulatory monitoring of HF patients in the outpatient setting. These monitors have evolved from piggybacking on cardiac implantable electrophysiologic devices to standalone implantable hemodynamic monitors that transduce left atrial or pulmonary artery pressures as surrogate measures of left ventricular filling pressure. As technology evolves, devices will likely continue to miniaturize while their capabilities grow. An important, persistent challenge that remains is developing systems to translate the large volumes of real-time data, particularly data trends, into actionable information that leads to appropriate, safe and timely interventions without overwhelming outpatient cardiology and general medical practices. Future directions for implantable hemodynamic monitors beyond their utility in heart failure may include management of other major chronic diseases such as pulmonary hypertension, end stage renal disease and portal hypertension.

  17. Evolution from electrophysiologic to hemodynamic monitoring: the story of left atrial and pulmonary artery pressure monitors.

    Science.gov (United States)

    Mooney, Deirdre M; Fung, Erik; Doshi, Rahul N; Shavelle, David M

    2015-01-01

    Heart failure (HF) is a costly, challenging and highly prevalent medical condition. Hospitalization for acute decompensation is associated with high morbidity and mortality. Despite application of evidence-based medical therapies and technologies, HF remains a formidable challenge for virtually all healthcare systems. Repeat hospitalizations for acute decompensated HF (ADHF) can have major financial impact on institutions and resources. Early and accurate identification of impending ADHF is of paramount importance yet there is limited high quality evidence or infrastructure to guide management in the outpatient setting. Historically, ADHF was identified by physical exam findings or invasive hemodynamic monitoring during a hospital admission; however, advances in medical microelectronics and the advent of device-based diagnostics have enabled long-term ambulatory monitoring of HF patients in the outpatient setting. These monitors have evolved from piggybacking on cardiac implantable electrophysiologic devices to standalone implantable hemodynamic monitors that transduce left atrial or pulmonary artery pressures as surrogate measures of left ventricular filling pressure. As technology evolves, devices will likely continue to miniaturize while their capabilities grow. An important, persistent challenge that remains is developing systems to translate the large volumes of real-time data, particularly data trends, into actionable information that leads to appropriate, safe and timely interventions without overwhelming outpatient cardiology and general medical practices. Future directions for implantable hemodynamic monitors beyond their utility in heart failure may include management of other major chronic diseases such as pulmonary hypertension, end stage renal disease and portal hypertension.

  18. Relation of Left Atrial Size, Cardiac Morphology, and Clinical Outcome in Asymptomatic Aortic Stenosis

    DEFF Research Database (Denmark)

    Christensen, Nicolaj Lyhne; Dahl, Jordi; Carter-Storch, Rasmus

    2017-01-01

    characterized by higher LV mass index (73 ± 17 g/m² vs. 66 ± 16 g/m² , p=0.03), increased right ventricle (70 ± 14 ml/m² vs. 63 ± 12 ml/m², p=0.01) and LV end-diastolic volume index (84 ± 18 ml/m² vs. 77 ± 16 ml/m², p=0.05), and higher brain natriuretic peptide (BNP). No difference in late enhancement was seen......Left atrial (LA) dilatation in asymptomatic severe aortic stenosis (AS) may be an indicator of advanced disease. The aim was to investigate the association between LA volume index (LAVi) and left ventricular (LV) morphology assessed with cardiac magnetic resonance imaging (cMRI), and to assess...... underwent echocardiography, cMRI, exercise test, and patients were followed for the composite endpoint of death, readmission or aortic valve replacement. AVA index was similar (0.45 ± 0.08 cm² /m² vs. 0.45 ± 0.09 cm², p=0.85) in patients with a dilated and normal LA. On cMRI patients with dilated LA were...

  19. Prospective randomized evaluation of the watchman left atrial appendage closure device in patients with atrial fibrillation versus long-term warfarin therapy: The PREVAIL trial.

    Science.gov (United States)

    Belgaid, Djouhar Roufeida; Khan, Zara; Zaidi, Mariam; Hobbs, Adrian

    2016-09-15

    Assessing the safety and effectiveness of left atrial appendage (LAA) (pouch found in the upper chambers of the heart) occlusion, using the Watchman device compared to long term warfarin therapy (drug that reduces clot formation), in preventing the risk of stroke in patients with atrial fibrillation (most common type of irregular heart beat). 90% of strokes in atrial fibrillation arise from clots forming in this pouch. By mechanically blocking it using the device less clots are suggested to be formed. This is an alternative to taking warfarin especially in patients who cannot take it. 50 sites in the United States enrolled 407 participants. After being randomly allocated, the device group had 269 participants and warfarin group (comparator)had 138 participants. Patients with atrial fibrillation and at high risk of stroke were randomly allocated a group after they were deemed eligible. Patients in the device group had to take warfarin and aspirin for 45days till the complete closure of the LAA. The oral anticoagulant was followed by dual antiplatelet therapy until 6months and then ASA. Patients in the warfarin group have to take it for life and were continually monitored. The study ran for 26months. The trial assessed the rate of adverse events using three endpoints: The PREVAIL trial was not designed to show superiority, but non-inferiority. It met the safety endpoint and one efficacy endpoint for the watchman device compared to long term warfarin for overall efficacy of the device. The results established that LAA occlusion is not worse than warfarin intake for the prevention of stroke more than 1week after randomization. Compared to previous trials, the safety of the device has also improved. LAA occlusion is a reasonable alternative to chronic warfarin therapy in stroke prevention for patients with atrial fibrillation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. Cost-Effectiveness of Percutaneous Closure of the Left Atrial Appendage in Atrial Fibrillation Based on Results From PROTECT AF Versus PREVAIL.

    Science.gov (United States)

    Freeman, James V; Hutton, David W; Barnes, Geoffrey D; Zhu, Ruo P; Owens, Douglas K; Garber, Alan M; Go, Alan S; Hlatky, Mark A; Heidenreich, Paul A; Wang, Paul J; Al-Ahmad, Amin; Turakhia, Mintu P

    2016-06-01

    Randomized trials of left atrial appendage (LAA) closure with the Watchman device have shown varying results, and its cost effectiveness compared with anticoagulation has not been evaluated using all available contemporary trial data. We used a Markov decision model to estimate lifetime quality-adjusted survival, costs, and cost effectiveness of LAA closure with Watchman, compared directly with warfarin and indirectly with dabigatran, using data from the long-term (mean 3.8 year) follow-up of Percutaneous Closure of the Left Atrial Appendage Versus Warfarin Therapy for Prevention of Stroke in Patients With Atrial Fibrillation (PROTECT AF) and Prospective Randomized Evaluation of the Watchman LAA Closure Device in Patients With Atrial Fibrillation (PREVAIL) randomized trials. Using data from PROTECT AF, the incremental cost-effectiveness ratios compared with warfarin and dabigatran were $20 486 and $23 422 per quality-adjusted life year, respectively. Using data from PREVAIL, LAA closure was dominated by warfarin and dabigatran, meaning that it was less effective (8.44, 8.54, and 8.59 quality-adjusted life years, respectively) and more costly. At a willingness-to-pay threshold of $50 000 per quality-adjusted life year, LAA closure was cost effective 90% and 9% of the time under PROTECT AF and PREVAIL assumptions, respectively. These results were sensitive to the rates of ischemic stroke and intracranial hemorrhage for LAA closure and medical anticoagulation. Using data from the PROTECT AF trial, LAA closure with the Watchman device was cost effective; using PREVAIL trial data, Watchman was more costly and less effective than warfarin and dabigatran. PROTECT AF enrolled more patients and has substantially longer follow-up time, allowing greater statistical certainty with the cost-effectiveness results. However, longer-term trial results and postmarketing surveillance of major adverse events will be vital to determining the value of the Watchman in clinical

  1. Prognostic value of CT-derived left atrial and left ventricular measures in patients with acute chest pain

    Energy Technology Data Exchange (ETDEWEB)

    Takx, Richard A.P. [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, University Medical Center Utrecht (Netherlands); Vliegenthart, Rozemarijn [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); University of Groningen/University Medical Center Groningen, Center for Medical Imaging − North East Netherlands, Department of Radiology, Groningen (Netherlands); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States); Nance, John W. [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Bamberg, Fabian [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Diagnostic and Interventional Radiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Abro, Joseph A. [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Carr, Christine M. [Division of Emergency Medicine, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States); Litwin, Sheldon E. [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States); and others

    2017-01-15

    Highlights: • LV mass and LA diameter are independent prognostic factor for composite MACE. • LV mass and LA diameter were not significant prognostic factors for MACE in African Americans. • Assessment of LV mass by CT may have a role in the management of patients. - Abstract: Purpose: To determine which left atrial (LA) and left ventricular (LV) parameters are associated with future major adverse cardiac event (MACE) and whether these measurements have independent prognostic value beyond risk factors and computed tomography (CT)-derived coronary artery disease measures. Materials and methods: This retrospective analysis was performed under an IRB waiver and in HIPAA compliance. Subjects underwent coronary CT angiography (CCTA) using a dual-source CT system for acute chest pain evaluation. LV mass, LV ejection fraction (EF), LV end-systolic volume (ESV) and LV end-diastolic volume (EDV), LA ESV and LA diameter, septal wall thickness and cardiac chamber diameters were measured. MACE was defined as cardiac death, non-fatal myocardial infarction, unstable angina, or late revascularization. The association between cardiac CT measures and the occurrence of MACE was quantified using Cox proportional hazard analysis. Results: 225 subjects (age, 56.2 ± 11.2; 140 males) were analyzed, of whom 42 (18.7%) experienced a MACE during a median follow-up of 13 months. LA diameter (HR:1.07, 95%CI:1.01–1.13 per mm) and LV mass (HR:1.05, 95%CI:1.00–1.10 per g) remained significant prognostic factor of MACE after controlling for Framingham risk score. LA diameter and LV mass were also found to have prognostic value independent of each other. The other morphologic and functional cardiac measures were no significant prognostic factors for MACE. Conclusion: CT-derived LA diameter and LV mass are associated with future MACE in patients undergoing evaluation for chest pain, and portend independent prognostic value beyond traditional risk factors, coronary calcium score, and

  2. Radionuclide analysis of right and left ventricular response to exercise in patients with atrial and ventricular septal defects

    International Nuclear Information System (INIS)

    Peter, C.A.; Bowyer, K.; Jones, R.H.

    1983-01-01

    In patients with ventricular or atrial septal defect, the ventricle which is chronically volume overloaded might not appropriately respond to increased demand for an augmentation in output and thereby might limit total cardiac function. In this study we simultaneously measured right and left ventricular response to exercise in 10 normal individuals, 10 patients with ventricular septal defect (VSD), and 10 patients with atrial septal defect (ASD). The normal subjects increased both right and left ventricular ejection fraction, end-diastolic volume, and stroke volume to achieve a higher cardiac output during exercise. Patients with VSD failed to increase right ventricular ejection fraction, but increased right ventricular end-diastolic volume and stroke volume. Left ventricular end-diastolic volume did not increase in these patients but ejection fraction, stroke volume, and forward left ventricular output achieved during exercise were comparable to the response observed in healthy subjects. In the patients with ASD, no rest-to-exercise change occurred in either right ventricular ejection fraction, end-diastolic volume, or stroke volume. In addition, left ventricular end-diastolic volume failed to increase, and despite an increase in ejection fraction, left ventricular stroke volume remained unchanged from rest to exercise. Therefore, cardiac output was augmented only by the heart rate increase in these patients. Right ventricular function appeared to be the major determinant of total cardiac output during exercise in patients with cardiac septal defects and left-to-right shunt

  3. Superior transseptal approach to mitral valve is associated with a higher need for pacemaker implantation than the left atrial approach

    DEFF Research Database (Denmark)

    Lukac, Peter; Hjortdal, Vibeke E; Pedersen, Anders K

    2006-01-01

    retrospectively evaluated. The surgeons used either the superior transseptal (group A) or left atrial approach (group B). The risk of pacemaker implantation associated with the superior transseptal approach as compared with the left atrial approach was estimated using the multivariate Cox regression analysis...... to adjust for possible confounders. RESULTS: We included 577 patients, 150 in group A and 427 in group B. Forty-four patients had a pacemaker implanted after the surgery; 17 in group A and 27 in group B (p = 0.010). The superior transseptal approach was an independent risk factor of pacemaker implantation...... in multivariate analysis (hazard ratio 2.2 [1.2 to 4.1], p = 0.014). Nineteen patients had a pacemaker implanted because of sinus node dysfunction; 9 in group A and 10 in group B (p = 0.017). Group A was an independent predictor of pacemaker implantation because of sinus node dysfunction in bivariate analyses...

  4. Pulmonary venous flows reflect changes in left atrial hemodynamics during mitral balloon valvotomy.

    Science.gov (United States)

    Yalçin, Fatih; El-Amrousy, Mahmoud; Müderrisoğlu, Haldun; Korkmaz, Mehmet; Flachskampf, Frank; Tuzcu, Murat; Garcia, Mario G; Thomas, James D

    2002-01-01

    Patients with mitral stenosis have usually blunted pulmonary venous (PV) flow, because of decreased mitral valve area and diastolic dysfunction. The authors compared changes in Doppler PV velocities by using transesophageal echocardiography (TEE) against hemodynamics parameters before and after mitral balloon valvotomy to observe relevance of PV velocities and endsystolic left atrial (LA) pressure-volume relationship. In 25 patients (aged 35 +/- 17 years) with mitral stenosis in sinus rhythm, changes in LA pressure and volumes were compared with PV velocities before and after valvotomy. Mitral valve area, mitral gradients, and deceleration time were obtained. Mitral valve area and mitral gradients changed from 1 +/- 0.2 cm2 and 14.6 +/- 5.4 mmHg to 1.9 +/- 0.3 cm2 and 6.3 +/- 1.7 mmHg, respectively (pLA pressure were correlated with changes in S/D (r=0.57, pLA pressure-volume relationship were also correlated with changes in S/D (r=0.52, pLA pressure-volume relationship decreased after mitral balloon valvotomy, as a result of a large decrease in pressure. PV systolic/diastolic (S/D) waves ratio reflects endsystolic LA pressure-volume relationship and may be used as another indicator of successful valvotomy.

  5. Exchanging Catheters Over a Single Transseptal Sheath During Left Atrial Ablation is Associated with a Higher Risk for Silent Cerebral Events

    Directory of Open Access Journals (Sweden)

    Thomas Deneke, MD

    2014-09-01

    Conclusions: Exchanging catheters over a single transseptal access to perform left atrial ablation is associated with a significantly higher incidence of SCE compared to an ablation technique using different transseptal accesses for therapeutic and diagnostic catheters.

  6. Epicardial fat thickness correlates with P-wave duration, left atrial size and decreased left ventricular systolic function in morbid obesity.

    Science.gov (United States)

    Fernandes-Cardoso, A; Santos-Furtado, M; Grindler, J; Ferreira, L A; Andrade, J L; Santo, M A

    2017-08-01

    Epicardial fat (EF) is increased in obesity and has important interactions with atrial and ventricular myocardium. Most of the evidence in this scenario can be confused by the presence of comorbidities such as hypertension, diabetes and dyslipidemia, which are very common in this population. The influence of EF on atrial remodeling and cardiac function demands further investigation on morbidly obese without these comorbidities. We prospectively recruited 20 metabolically healthy morbidly obese and 20 normo-weights controls. The maximum P-wave duration (PWD) was analyzed by 12-lead electrocardiogram. Left atrial diameter (LAD), left ventricular ejection fraction (LVEF) and EF thickness (EFT) were evaluated by two-dimensional echocardiography. The mean of maximum PWD and LAD were significantly larger in the obese group as compared to the control group: 109.55 ± 11.52 ms × 89.38 ± 11.19 ms and 36.12 ± 3.46 mm × 31.45 ± 2.64 mm, (p function. Copyright © 2017 The Italian Society of Diabetology, the Italian Society for the Study of Atherosclerosis, the Italian Society of Human Nutrition, and the Department of Clinical Medicine and Surgery, Federico II University. Published by Elsevier B.V. All rights reserved.

  7. Computed tomography measurement of the left atrial appendage for optimal sizing of the Watchman device.

    Science.gov (United States)

    Xu, Bo; Betancor, Jorge; Sato, Kimi; Harb, Serge; Abdur Rehman, Karim; Patel, Kunal; Kumar, Arnav; Cremer, Paul C; Jaber, Wael; Rodriguez, L Leonardo; Schoenhagen, Paul; Wazni, Oussama

    Percutaneous left atrial appendage (LAA) occlusion is an emerging treatment option for patients with non-valvular atrial fibrillation who cannot tolerate oral anticoagulation. The Watchman device (Boston Scientific Corporation, Natick, MA, USA) is deployed at the ostium of the LAA, and an appropriately sized device is critical for successful occlusion. However, standardized imaging protocols for device sizing have not been established. We investigated the clinical utility of a standardized imaging protocol, with pre-procedural multi-detector cardiac computed tomography (MDCT), and intra-procedural transesophageal echocardiography (TEE), for Watchman device sizing. Patients who underwent Watchman device implantation between 2010 and 2016 at our center, and who had pre-procedural MDCT and intra-procedural TEE were included. MDCT measurements (CTmax, CTmin, CTmean), and TEE measurement (TEEmax) of the LAA ostium were determined for each case, and correlated with the final size of the Watchman device implanted. Demographic data and clinical outcomes were collected. The study included 80 patients (mean age: 75 ± 9.6 years; male: 68%; mean CHA2DS2-VASc score: 4.5 ± 1.4). CTmax of the LAA ostium correlated strongly with the final deployed Watchman device size (Spearman's rho: 0.81, p < 0.001), while TEEmax of the LAA ostium showed only moderate correlation with the final deployed Watchman device size (Spearman's rho: 0.61, p < 0.001). Implantation success rate was 100%. At a mean duration of follow-up of 197 days, there were no device-related complications (device embolization, cardiac perforation and pericardial tamponade). At follow-up, the vast majority of patients (76 patients; 95%) had either no or trivial (≤3 mm) residual peri-device leak on TEE. A standardized imaging protocol for assessment of Watchman device implantation incorporating pre-procedural MDCT and intra-procedural TEE, was associated with excellent procedural outcomes at a mean duration

  8. Left and right atrial feature tracking in acute myocarditis: A feasibility study

    International Nuclear Information System (INIS)

    Dick, Anastasia; Schmidt, Björn; Michels, Guido; Bunck, Alexander C.; Maintz, David; Baeßler, Bettina

    2017-01-01

    Purpose: The present study aims at evaluating the feasibility and reproducibility of cardiac magnetic resonance (CMR) feature tracking (FT) derived strain and strain rate (SR) parameters of the left and right atrium (LA, RA) in patients with acute myocarditis as well as their potential to detect diastolic dysfunction. In addition, the diagnostic value of LA and RA strain parameters in the setting of acute myocarditis is investigated. Methods: CMR cine data of 30 patients with CMR-positive acute myocarditis were retrospectively analyzed. 25 age- and gender-matched healthy individuals served as a control. Analysis of longitudinal strain and SR of both atria was performed in two long-axis views using a dedicated FT-software. LA and RA deformation was analyzed including reservoir function (total strain [ε s ], peak positive SR [SR s ]), conduit function (passive strain [ε e ], peak early negative SR [SR e ]) and booster pump function (active strain [ε a ], peak late negative SR [SR a ]). Intra- and inter-observer reproducibility was assessed for all strain and SR parameters using Bland-Altman analyses, intra-class correlation coefficients (ICCs) and coefficients of variation (CV). Results: FT analyses of both atria were feasible in all patients and controls. Reproducibility was good for reservoir and conduit function parameters and moderate for booster pump function parameters. Myocarditis patients demonstrated an impaired LA reservoir and conduit function when compared to healthy controls (LA ε s : 32 ± 17 vs. 46 ± 13, p = 0.019; LA SR s : 1.5 ± 0.5 vs. 1.8 ± 0.5, p = 0.117; LA SR e : −1.3 ± 0.5 vs. −1.9 ± 0.5, p < 0.001), while LA booster pump function was preserved. In logistic regression and ROC-analyses, LA SR e proved to be the best independent predictor of acute myocarditis (AUC 0.80), and using LA SR e with a cut-off of −1.6 s −1 resulted in a diagnostic sensitivity of 83% and a specificity of 80%. Changes in RA phasic function parameters

  9. Diastolic dysfunction predicts new-onset atrial fibrillation and cardiovascular events in patients with acute myocardial infarction and depressed left ventricular systolic function: a CARISMA substudy

    DEFF Research Database (Denmark)

    Jons, Christian; Joergensen, Rikke Moerch; Hassager, Christian

    2010-01-01

    The aim of this study was to investigate the association between diastolic dysfunction and long-term occurrence of new-onset atrial fibrillation (AF) and cardiac events in patients with acute myocardial infarction (AMI) and left ventricular (LV) systolic dysfunction.......The aim of this study was to investigate the association between diastolic dysfunction and long-term occurrence of new-onset atrial fibrillation (AF) and cardiac events in patients with acute myocardial infarction (AMI) and left ventricular (LV) systolic dysfunction....

  10. Effect of preload reduction by hemodialysis on left atrial volume and echocardiographic Doppler parameters in patients with end-stage renal disease.

    Science.gov (United States)

    Barberato, Silvio H; Mantilla, Diego E V; Misocami, M Arcio; Gonçalves, Simone M; Bignelli, Alexandre T; Riella, Miguel C; Pecoits-Filho, Roberto

    2004-11-01

    Left atrial (LA) volume has been proposed as a less preload-dependent parameter of diastolic function than Doppler mitral inflow. We hypothesize that in the absence of mitral regurgitation and atrial fibrilation, LA enlargement could be a more practical (and relatively preload-independent) method for the evaluation of left ventricular diastolic function. The aim of the present study was to determine the effects of preload reduction by hemodialysis on LA volume.

  11. Left ventricular outflow tract to left atrial communication secondary to rupture of mitral-aortic intervalvular fibrosa in infective endocarditis: diagnosis by transesophageal echocardiography and color flow imaging.

    Science.gov (United States)

    Bansal, R C; Graham, B M; Jutzy, K R; Shakudo, M; Shah, P M

    1990-02-01

    Infection of the mitral-aortic intervalvular fibrosa occurs most commonly in association with infective endocarditis of the aortic valve. Infection of the aortic valve results in a regurgitant jet that presumably strikes this subaortic interannular zone of fibrous tissue and produces a secondary site of infection. Infection of this interannular zone then leads to the formation of subaortic abscess or pseudoaneurysm of the left ventricular outflow tract. This infected zone of mitral-aortic intervalvular fibrosa or subaortic aneurysm can subsequently rupture into the left atrium with systolic ejection of blood from the left ventricular outflow tract to the left atrium. This report describes the echocardiographic findings in three patients with pathologically proved left ventricular outflow tract to left atrial communication. Precise preoperative diagnosis is important, and this lesion should be differentiated from ruptured aneurysm of the sinus of Valsalva and perforation of the anterior mitral leaflet. Transthoracic echocardiography using color flow imaging and conventional Doppler techniques may show an eccentric mitral regurgitation type of signal in the left atrium originating from the region of the left ventricular outflow tract. However, transesophageal echocardiography provides an accurate preoperative diagnosis and should be used intraoperatively during repair of such lesions.

  12. Noninvasive assessment of left atrial maximum dP/dt by a combination of transmitral and pulmonary venous flow.

    Science.gov (United States)

    Nakatani, S; Garcia, M J; Firstenberg, M S; Rodriguez, L; Grimm, R A; Greenberg, N L; McCarthy, P M; Vandervoort, P M; Thomas, J D

    1999-09-01

    The study assessed whether hemodynamic parameters of left atrial (LA) systolic function could be estimated noninvasively using Doppler echocardiography. Left atrial systolic function is an important aspect of cardiac function. Doppler echocardiography can measure changes in LA volume, but has not been shown to relate to hemodynamic parameters such as the maximal value of the first derivative of the pressure (LA dP/dt(max)). Eighteen patients in sinus rhythm were studied immediately before and after open heart surgery using simultaneous LA pressure measurements and intraoperative transesophageal echocardiography. Left atrial pressure was measured with a micromanometer catheter, and LA dP/dt(max) during atrial contraction was obtained. Transmitral and pulmonary venous flow were recorded by pulsed Doppler echocardiography. Peak velocity, and mean acceleration and deceleration, and the time-velocity integral of each flow during atrial contraction was measured. The initial eight patients served as the study group to derive a multilinear regression equation to estimate LA dP/dt(max) from Doppler parameters, and the latter 10 patients served as the test group to validate the equation. A previously validated numeric model was used to confirm these results. In the study group, LA dP/dt(max) showed a linear relation with LA pressure before atrial contraction (r = 0.80, p LA. Among transmitral flow parameters, mean acceleration showed the strongest correlation with LA dP/dt(max) (r = 0.78, p LA dP/dt(max) with an r2 > 0.30. By stepwise and multiple linear regression analysis, LA dP/dt(max) was best described as follows: LA dP/dt(max) = 0.1 M-AC +/- 1.8 P-V - 4.1; r = 0.88, p LA dP/dt(max) correlated well (r = 0.90, p LA dP/dt(max) predicted by the above equation with r = 0.94. A combination of transmitral and pulmonary venous flow parameters can provide a hemodynamic assessment of LA systolic function.

  13. Thyrotropin modulates receptor-mediated processing of the atrial natriuretic peptide receptor in cultured thyroid cells

    International Nuclear Information System (INIS)

    Tseng, Y.L.; Burman, K.D.; Lahiri, S.; Abdelrahim, M.M.; D'Avis, J.C.; Wartofsky, L.

    1991-01-01

    In a prior study of atrial natriuretic peptide (ANP) binding to cultured thyroid cells, we reported that at 4 C, more than 95% of bound ANP is recovered on cell membranes, with negligible ANP internalization observed. Since ANP binding was inhibited by TSH, we have further studied TSH effects on postbinding ANP processing to determine whether this phenomenon reflects enhanced endocytosis of the ANP-receptor complex. An ANP chase study was initiated by binding [125I] ANP to thyroid cells at 4 C for 2 h, followed by incubation at 37 C. ANP processing was then traced by following 125I activity at various time intervals in three fractions: cell surface membranes, incubation medium, and inside the cells. Radioactivity released into medium represented processed ANP rather than ANP dissociated from surface membranes, since prebound [125I]ANP could not be competitively dissociated by a high concentration of ANP (1 mumol/L) at 37 C. Chase study results showed that prebound ANP quickly disappeared from cell membranes down to 34% by 30 min. Internalized ANP peaked at 10 min, with 21% of initial prebound ANP found inside the cells. At the same time, radioactivity recovered in incubation medium sharply increased between 10-30 min from 8% to 52%. Preincubation of cells with chloroquine (which blocks degradation of the ANP-receptor complex by inhibiting lysosomal hydrolase) caused a 146% increase in internalized [125I]ANP by 30 min (39% compared to 15% control), while medium radioactivity decreased from 52% to 16%, suggesting that processing of the receptor complex is mediated via lysosomal enzymes. In chase studies employing cells pretreated with chloroquine, TSH stimulated the internalization rate of ANP-receptor complex. By 30 min, TSH significantly reduced the membrane-bound ANP, and the decrease was inversely correlated to the increase in internalized radioactivity

  14. Prognostic value of left atrial size and function in adults with tetralogy of Fallot.

    Science.gov (United States)

    Baggen, Vivan J M; Schut, Anne-Rose W; Cuypers, Judith A A E; Witsenburg, Maarten; Boersma, Eric; van den Bosch, Annemien E; Roos-Hesselink, Jolien W

    2017-06-01

    Left atrial (LA) size predicts cardiovascular outcome in chronic heart failure. Its prognostic value in adults with repaired tetralogy of Fallot (ToF) is unknown. This study therefore investigated the association of LA size and function with cardiovascular events in adults with ToF. Clinically stable adults with ToF who visited the outpatient clinic between 2011 and 2013 underwent echocardiography and were prospectively followed for the occurrence of death, heart failure, hospitalizations, arrhythmia, thromboembolic events, and re-interventions. LA maximal, minimal and pre-A wave volume, area and length were measured on the apical four-chamber view. Total, passive and active emptying fractions were calculated. In total, 134 patients were included (median age 35 [IQR 29-45] years, 65% male, 91% NYHA I). Median follow-up was 40 [IQR 32-47] months. Patients with a dilated LA (≥34mL/m 2 , 43%) were at higher risk of cardiovascular events (n=33, adjusted HR 2.48 [1.09-5.62], P=0.030). Analysis of LA volumes as continuous variables yielded similar conclusions. In addition, LA length (adjusted HR 2.49 [1.51-4.09], P<0.001), total emptying fraction (adjusted HR 0.96 [0.93-0.99], P=0.008), and active emptying fraction (adjusted HR 0.92 [0.87-0.96], P=0.001) were significantly associated with cardiovascular events. Standardized HRs indicated that LA length was the strongest prognostic marker. In addition, none of the patients with a normally sized LA died or developed heart failure. LA size and function can provide relevant prognostic information in clinically stable adults with repaired ToF. Especially LA length may be a valuable additional tool in the risk stratification of these patients. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Evaluation of Left Atrial Volumes Using Multidetector Computed Tomography: Comparison with Echocardiography

    International Nuclear Information System (INIS)

    Gweon, Hye Mi; Kim, Sang Jin; Kim, Tae Hoon; Lee, Sang Min; Hong, Yoo Jin; Rim, Se Joong

    2010-01-01

    To prospectively assess the relationship between the two different measurement methods for the evaluation of left atrial (LA) volume using cardiac multidetector computed tomography (MDCT) and to compare the results between cardiac MDCT and echocardiography. Thirty-five patients (20 men, 15 women; mean age, 60 years) underwent cardiac MDCT angiography for coronary artery disease. The LA volumes were measured using two different methods: the two dimensional (2D) length-based (LB) method measured along the three-orthogonal planes of the LA and the 3D volumetric threshold-based (VTB) method measured according to the threshold 3D segmentation of the LA. The results obtained by cardiac MDCT were compared with those obtained by echocardiography. The LA end-systolic and end-diastolic volumes (LAESV and LAEDV) measured by the 2D-LB method correlated well with those measured by the 3DVTB method using cardiac MDCT (r = 0.763, r = 0.786, p = 0.001). However, there was a significant difference in the LAESVs between the two measurement methods using cardiac MDCT (p < 0.05). The LAESV measured by cardiac MDCT correlated well with measurements by echocardiography (r = 0.864, p = 0.001), however with a significant difference (p < 0.01) in their volumes. The cardiac MDCT overestimated the LAESV by 22% compared to measurements by echocardiography. A significant correlation was found between the two different measurement methods for evaluating LA volumes by cardiac MDCT. Further, cardiac MDCT correlates well with echocardiography in evaluating the LA volume. However, there are significant differences in the LAESV between the two measurement methods using cardiac MDCT and between cardiac MDCT and echocardiography

  16. Preoperative atrial fibrillation increases risk of thromboembolic events after left ventricular assist device implantation.

    Science.gov (United States)

    Stulak, John M; Deo, Salil; Schirger, John; Aaronson, Keith D; Park, Soon J; Joyce, Lyle D; Daly, Richard C; Pagani, Francis D

    2013-12-01

    Because no series has specifically analyzed the impact of preoperative atrial fibrillation (AF) on patients already at higher risk of thromboembolism after implantation of a left ventricular assist device (LVAD), we review our experience with these patients. Between July 2003 and September 2011, 389 patients (308 male) underwent implantation of a continuous flow LVAD at University of Michigan Hospital and Mayo Clinic. Median age at implant was 60 years (range, 18 to 79 years). Preoperative AF was present in 120 patients (31%). Outcomes were analyzed for the association of preoperative AF and postoperative thromboembolic (TE) events defined as stroke, transient ischemic attack, hemolysis, or pump thrombosis. Thromboembolic events occurring within the first 30 days were not counted. One hundred thirty-eight TEs events occurred in 97/389 patients (25%) for an event rate of 0.31 TE events/patient-years of support. Freedom from a TE event in patients with preoperative AF was 62% at 1 year and 46% at 2 years compared with 79% and 72% at 1 and 2 years, respectively, in patients without preoperative AF (p < 0.001). Median survival was 10 months (maximum 7.2 years, total 439 patient-years). Preoperative AF did not decrease late survival at 1 and 2 years after LVAD implant (preop AF: 85% and 70% versus no preop AF: 82% and 70%, respectively; p = 0.55). Patients with preoperative AF have a lower freedom from TE events after LVAD implant. While overall late survival was not significantly reduced in these patients, refinement in anticoagulation strategies after VAD implant may be required. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Left Atrial Volume Index and Prediction of Events in Acute Coronary Syndrome: Solar Registry

    Directory of Open Access Journals (Sweden)

    Jose Alves Secundo Junior

    2014-10-01

    Full Text Available Background: According to some international studies, patients with acute coronary syndrome (ACS and increased left atrial volume index (LAVI have worse long-term prognosis. However, national Brazilian studies confirming this prediction are still lacking. Objective: To evaluate LAVI as a predictor of major cardiovascular events (MCE in patients with ACS during a 365-day follow-up. Methods: Prospective cohort of 171 patients diagnosed with ACS whose LAVI was calculated within 48 hours after hospital admission. According to LAVI, two groups were categorized: normal LAVI (≤ 32 mL/m2 and increased LAVI (> 32 mL/m2. Both groups were compared regarding clinical and echocardiographic characteristics, in- and out-of-hospital outcomes, and occurrence of ECM in up to 365 days. Results: Increased LAVI was observed in 78 patients (45%, and was associated with older age, higher body mass index, hypertension, history of myocardial infarction and previous angioplasty, and lower creatinine clearance and ejection fraction. During hospitalization, acute pulmonary edema was more frequent in patients with increased LAVI (14.1% vs. 4.3%, p = 0.024. After discharge, the occurrence of combined outcome for MCE was higher (p = 0.001 in the group with increased LAVI (26% as compared to the normal LAVI group (7% [RR (95% CI = 3.46 (1.54-7.73 vs. 0.80 (0.69-0.92]. After Cox regression, increased LAVI increased the probability of MCE (HR = 3.08, 95% CI = 1.28-7.40, p = 0.012. Conclusion: Increased LAVI is an important predictor of MCE in a one-year follow-up.

  18. Occult left atrial ball-like thrombus in a patient referred for surgical removal of suspected cerebellum tumor

    International Nuclear Information System (INIS)

    Możeńska, Olga; Kalińska, Irena; Brodowski, Karol; Walecki, Jerzy; Kosior, Dariusz A.

    2014-01-01

    Atrial fibrillation and related cardio-embolic cerebrovascular accidents are two well-defined major healthcare problems worldwide. It has been approximated that 2.2 million people in America and 4.5 million in European Union have paroxysmal or persistent atrial fibrillation. And atrial fibrillation itself is an independent long-term risk factor of stroke. We present a case of patient referred to our center for surgical removal of suspected cerebellum tumor, a case that had a rather unexpected ending. A 58-year-old male patient with a history of atrial fibrillation, congestive heart failure (NYHA II/III), stable coronary artery disease, diabetes type 2 and hyperlipidemia presented with vertigo, headaches, mainly during physical activity and increased tiredness. Performed computer tomography revealed two lesions in the cerebellum and in the left lateral chamber. The diagnosis of a proliferative disease of the cerebellum was established and patient was referred to the Neurosurgical Department. Fortunately, before the operation the echocardiography was performed, which revealed two lesions in left atrium. The decision of the Heart Team was to refer the patient for an open-heart surgery, in which two thrombi were removed. Neurosurgeons decided to withdraw from further surgery and proceed with head MRI and conservative treatment, deciding that the lesion in the cerebellum was most likely an ischemic area. Looking at the brain lesion should always be done from the whole patient’s perspective. And using mutlimodality imaging may lead to appropriate diagnosis, correct course of therapeutic action and unexpected ending of a rather non-extraordinary case

  19. Left and right atrial feature tracking in acute myocarditis: A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Dick, Anastasia, E-mail: anastasia-dick@web.de [Department of Radiology, University Hospital of Cologne, Kerpener Str. 62, 50937 Cologne (Germany); Schmidt, Björn, E-mail: bjoernschmidt1989@gmx.de [Department of Radiology, University Hospital of Cologne, Kerpener Str. 62, 50937 Cologne (Germany); Michels, Guido, E-mail: guido.michels@uk-koeln.de [Department III of Internal Medicine, Heart Centre, University Hospital of Cologne, Kerpener Str. 62, 50937 Cologne (Germany); Bunck, Alexander C., E-mail: alexander.bunck@uk-koeln.de [Department of Radiology, University Hospital of Cologne, Kerpener Str. 62, 50937 Cologne (Germany); Maintz, David, E-mail: david.maintz@uk-koeln.de [Department of Radiology, University Hospital of Cologne, Kerpener Str. 62, 50937 Cologne (Germany); Baeßler, Bettina, E-mail: bettina.baessler@uk-koeln.de [Department of Radiology, University Hospital of Cologne, Kerpener Str. 62, 50937 Cologne (Germany)

    2017-04-15

    Purpose: The present study aims at evaluating the feasibility and reproducibility of cardiac magnetic resonance (CMR) feature tracking (FT) derived strain and strain rate (SR) parameters of the left and right atrium (LA, RA) in patients with acute myocarditis as well as their potential to detect diastolic dysfunction. In addition, the diagnostic value of LA and RA strain parameters in the setting of acute myocarditis is investigated. Methods: CMR cine data of 30 patients with CMR-positive acute myocarditis were retrospectively analyzed. 25 age- and gender-matched healthy individuals served as a control. Analysis of longitudinal strain and SR of both atria was performed in two long-axis views using a dedicated FT-software. LA and RA deformation was analyzed including reservoir function (total strain [ε{sub s}], peak positive SR [SR{sub s}]), conduit function (passive strain [ε{sub e}], peak early negative SR [SR{sub e}]) and booster pump function (active strain [ε{sub a}], peak late negative SR [SR{sub a}]). Intra- and inter-observer reproducibility was assessed for all strain and SR parameters using Bland-Altman analyses, intra-class correlation coefficients (ICCs) and coefficients of variation (CV). Results: FT analyses of both atria were feasible in all patients and controls. Reproducibility was good for reservoir and conduit function parameters and moderate for booster pump function parameters. Myocarditis patients demonstrated an impaired LA reservoir and conduit function when compared to healthy controls (LA ε{sub s}: 32 ± 17 vs. 46 ± 13, p = 0.019; LA SR{sub s}: 1.5 ± 0.5 vs. 1.8 ± 0.5, p = 0.117; LA SR{sub e}: −1.3 ± 0.5 vs. −1.9 ± 0.5, p < 0.001), while LA booster pump function was preserved. In logistic regression and ROC-analyses, LA SR{sub e} proved to be the best independent predictor of acute myocarditis (AUC 0.80), and using LA SR{sub e} with a cut-off of −1.6 s{sup −1} resulted in a diagnostic sensitivity of 83% and a specificity of

  20. Detection of left atrial thrombus in patients with mitral stenosis and atrial fibrillation: retrospective comparison of two-phase computed tomography, transoesophageal echocardiography and surgical findings

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Bo Hwa; Ko, Sung Min [Konkuk University Medical Center, Konkuk University School of Medicine, Department of Radiology, Research Institute of Medical Science, Seoul (Korea, Republic of); Hwang, Hweung Kon [Konkuk University Medical Center, Konkuk University School of Medicine, Department of Cardiology, Seoul (Korea, Republic of); Song, Meong Gun; Shin, Je Kyoun [Konkuk University Medical Center, Konkuk University School of Medicine, Department of Thoracic surgery, Seoul (Korea, Republic of); Kang, Woon Seok; Kim, Tae-Yop [Konkuk University Medical Center, Konkuk University School of Medicine, Department of Anesthesiology, Seoul (Korea, Republic of)

    2013-11-15

    This retrospective study aims to assess the accuracy of two-phase computed tomography (CT) and transoesophageal echocardiography (TEE) for the detection of left atrial (LA) thrombus in patients with mitral stenosis (MS) and atrial fibrillation (AF), by using intraoperative findings as the reference standard. Preoperative two-phase CT and intraoperative TEE were performed in 106 patients with MS and AF. The ratio (LAA/AA{sub L}) of Hounsfield units (HU) in the LA appendage (LAA) to the ascending aorta (AA) was calculated on the late-phase CT image. LA echodense masses on TEE and LA filling defects on two-phase CT were observed in 29 and 39 patients, respectively. Thirty-five LA thrombi were identified at surgery in 27 patients. Compared with the intraoperative findings, per-patient sensitivity, specificity, positive and negative predictive values of two-phase CT were 100 %, 85 %, 69 % and 100 %, and those by using TEE were 93 %, 95 %, 86 % and 97 % in detecting LAA thrombus. After adopting the cut-off value of 0.5 for the LAA/AA{sub L} HU ratio, the specificity and positive predictive value of two-phase CT were increased to 96 % and 90 %, respectively. Two-phase CT with a cut-off value of LAA/AA{sub L} HU ratio of 0.5 provides high performance for the detection of LAA thrombus. (orig.)

  1. Motion of left atrial appendage as a determinant of thrombus formation in patients with a low CHADS2 score receiving warfarin for persistent nonvalvular atrial fibrillation

    Directory of Open Access Journals (Sweden)

    Ono Koji

    2012-12-01

    Full Text Available Abstract Background The aim of this study was to define the independent determinants of left atrial appendage (LAA thrombus among various echocardiographic parameters measured by Velocity Vector Imaging (VVI in patients with nonvalvular atrial fibrillation (AF receiving warfarin, particularly in patients with a low CHADS2 score. Methods LAA emptying fraction (EF and LAA peak longitudinal strain were measured by VVI using transesophageal echocardiography in 260 consecutive patients with nonvalvular persistent AF receiving warfarin. The patients were divided into two groups according to the presence (n=43 or absence (n=217 of LAA thrombus. Moreover, the patients within each group were further divided into subgroups according to a CHADS2 score ≤1. Results Multivariate logistic regression analysis showed that LAAEF was an independent determinant of LAA thrombus in the subgroup of 140 with a low CHADS2 score. Receiver operating characteristics curve analysis showed that an LAAEF of 21% was the optimal cutoff value for predicting LAA thrombus. Conclusions LAA thrombus formation depended on LAA contractility. AF patients with reduced LAA contractile fraction (LAAEF ≤21% require strong anticoagulant therapy to avoid thromboembolic events regardless of a low CHADS2 score (≤1.

  2. New-Onset Atrial Fibrillation After PCI or CABG for Left Main Disease: The EXCEL Trial.

    Science.gov (United States)

    Kosmidou, Ioanna; Chen, Shmuel; Kappetein, A Pieter; Serruys, Patrick W; Gersh, Bernard J; Puskas, John D; Kandzari, David E; Taggart, David P; Morice, Marie-Claude; Buszman, Paweł E; Bochenek, Andrzej; Schampaert, Erick; Pagé, Pierre; Sabik, Joseph F; McAndrew, Thomas; Redfors, Björn; Ben-Yehuda, Ori; Stone, Gregg W

    2018-02-20

    There is limited information on the incidence and prognostic impact of new-onset atrial fibrillation (NOAF) following percutaneous coronary intervention (PCI) and coronary artery bypass grafting (CABG) for left main coronary artery disease (LMCAD). This study sought to determine the incidence of NOAF following PCI and CABG for LMCAD and its effect on 3-year cardiovascular outcomes. In the EXCEL (Evaluation of XIENCE Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization) trial, 1,905 patients with LMCAD and low or intermediate SYNTAX scores were randomized to PCI with everolimus-eluting stents versus CABG. Outcomes were analyzed according to the development of NOAF during the initial hospitalization following revascularization. Among 1,812 patients without atrial fibrillation on presentation, NOAF developed at a mean of 2.7 ± 2.5 days after revascularization in 162 patients (8.9%), including 161 of 893 (18.0%) CABG-treated patients and 1 of 919 (0.1%) PCI-treated patients (p EXCEL trial, NOAF was common after CABG but extremely rare after PCI. The development of NOAF was strongly associated with subsequent death and stroke in CABG-treated patients. Further studies are warranted to determine whether prophylactic strategies to prevent or treat atrial fibrillation may improve prognosis in patients with LMCAD who are undergoing CABG. (Evaluation of XIENCE Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization [EXCEL]; NCT01205776). Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  3. Percutaneous left atrial appendage occlusion: Effect of device positioning on outcome.

    Science.gov (United States)

    Wolfrum, Mathias; Attinger-Toller, Adrian; Shakir, Samera; Gloekler, Steffen; Seifert, Burkhardt; Moschovitis, Aris; Khattab, Ahmed; Maisano, Francesco; Meier, Bernhard; Nietlispach, Fabian

    2016-10-01

    The study in patients with percutaneous left atrial appendage (LAA) occlusion investigates clinical outcomes according to the position of the Amplatzer Cardiac Plug (ACP) disc. The ACP consists of a disc and an anchoring lobe. The disc is meant to cover the ostium of the LAA, but frequently retracts partially or completely into the neck of the LAA. It is not known whether a retracted disc affects outcome. Outcomes of 169 consecutive patients (age 73.1 ± 10.4 years; 76% male) with successful LAA closure were analyzed according to the position of the ACP disc: group A had complete coverage of the LAA ostium; in group B the disc prolapsed partially or completely into the LAA-neck. Transesophageal echocardiography was performed 1-6 months after ACP implantation. The safety endpoint was the composite of clinically significant pericardial effusion, device embolization, procedure-related stroke/transient ischemic attack (TIA), major bleeding, or device thrombus. The efficacy endpoint was the composite of death, neurological events (ischemic and hemorrhagic stroke, TIA), or systemic embolism during follow-up. Group A comprised 76 patients (age 73.0 ± 9.9 years; 74% male) and group B 93 patients (age 73.3 ± 10.9 years; 79% male). Mean CHA 2 DS 2 -Vasc score and HASBLED score were 4.2 ± 1.7 (group A 4.3 ± 1.6; group B 4.2 ± 1.8) and 2.9 ± 1.1 (group A 2.9 ± 1.0; group B 3.0 ± 1.2), respectively. Mean follow-up of the study population was 13.0 ± 10.4 months. Overall, the composite safety and efficacy endpoints occurred in 20 (12%) and 6 patients (4%), respectively. There was no significant difference between groups A and B in the occurrence of the safety endpoint (13% vs. 11%, P = 0.64), or the efficacy endpoint (4% vs. 3%, P = 1.0). No evidence for a difference in the occurrence of the safety and efficacy endpoint was found between patients with complete vs. incomplete ACP disc coverage of the LAA ostium. The risk of

  4. Prevalence and predictors of low voltage zones in the left atrium in patients with atrial fibrillation.

    Science.gov (United States)

    Huo, Yan; Gaspar, Thomas; Pohl, Matthias; Sitzy, Judith; Richter, Utz; Neudeck, Sebastian; Mayer, Julia; Kronborg, Mads Brix; Piorkowski, Christopher

    2017-06-10

    To describe the extent and distribution of low voltage zones (LVZ) in a large cohort of patients undergoing ablation for paroxysmal and persistent atrial fibrillation (AF), and to explore baseline predictors of LVZ in these patients. Consecutive patients who underwent a bipolar voltage map guided AF ablation, were enrolled. Voltage maps were conducted for each patient using 3-dimensional electroanatomical mapping system and LVZ were defined as areas of bipolar voltage voltage zones was present in 58 out of 292 patients with paroxysmal and 134 out of 247 persistent AF (P < 0.001). The area of LVZ was larger in patients with persistent as compare to paroxysmal AF, 5 cm2 (IQR 3-18.6) vs. 12.1 cm2 (IQR 3.6-28.5), P = 0.026, respectively. In the multivariate analysis age (OR 1.07, 95%CI 1.05-1.10, P < 0.001), female gender (OR 2.18, 95%CI 1.38-3.43, P = 0.001), sinoatrial node dysfunction (OR 3.90, 95%CI 1.24-12.21, P = 0.020), larger surface area of left atrium pr. cm2 (OR 1.01, 95%CI 1.00-1.02, P = 0.016), and persistent AF (OR 5.03, 95%CI 3.20-7.90, P<0.001) were associated with presence of LVZ. In a large cohort of patients undergoing ablation for AF, the prevalence of LVZ was higher and LVZ areas larger in patients with persistent as compared with paroxysmal AF. The most frequent localization of LVZ was anterior wall, septum and posterior wall. Presence of LVZ was associated with higher age, female gender, larger LA surface area, and sinoatrial node dysfunction. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  5. Trandolapril reduces the incidence of atrial fibrillation after acute myocardial infarction in patients with left ventricular dysfunction

    DEFF Research Database (Denmark)

    Pedersen, O D; Bagger, H; Køber, Lars Valeur

    1999-01-01

    in patients with reduced left ventricular function secondary to acute myocardial infarction. The patients in this study were those who qualified for inclusion into the TRAndolapril Cardiac Evaluation (TRACE) study, a randomized double-blind placebo-controlled study and who had sinus rhythm on the ECG obtained...... at randomization. Patients who fulfilled the criteria for inclusion were randomized to treatment with the ACE inhibitor trandolapril or placebo and were followed up for 2 to 4 years. Development and time to occurrence of atrial fibrillation in one 12-lead ECG recorded at the outpatient visits was the primary end...

  6. Quantification of left to right shunts in adults with atrial septal defects of secundum type, using radionuclide technique

    International Nuclear Information System (INIS)

    Sire, S.; Rootwelt, K.; Mangschau, A.

    1991-01-01

    Quantification of left to right shunt was carried out in 15 adult patients with a suspected ostium secundum atrial septal defect (ASD II). Radionuclide shunt quantitation correlated well with the results of righ heart catheterization. The radionuclide technique failed in two patients for technical reasons, but revealed no false negative or false positive results when technically satisfactory. The diagnosis was confirmed at operation. It is concluded that the radionuclide technique is a useful and reliable method which can also be used at follow-up after surgery in patients with artrial septal defects of secundum type. 20 refs., 3 figs., 1 tab

  7. Creation of a restrictive atrial communication in heart failure with preserved and mid-range ejection fraction: effective palliation of left atrial hypertension and pulmonary congestion.

    Science.gov (United States)

    Bauer, Anna; Khalil, Markus; Lüdemann, Monika; Bauer, Jürgen; Esmaeili, Anoosh; De-Rosa, Roberta; Voelkel, Norbert F; Akintuerk, Hakan; Schranz, Dietmar

    2018-04-16

    Left atrial decompression is considered in patients with symptomatic heart failure with preserved ejection fraction (HFpEF). We aimed to evaluate the feasibility and efficacy of transcatheter generation of a restrictive atrial septum communication to manage HFpEF from infancy to adulthood with cardiomyopathy and congenital heart defect. From June 2009 to December 2016, 24 patients (50% with an age less than 16 years) with HFpEF were palliated; NYHA-/Ross class IV (n = 10); median systemic ventricular ejection fraction 64 (range 35-78) %. Cardiomyopathy was classified as a restrictive (n = 4) or hypertrophic (n = 2). (75% related to congenital heart defects) Three patients had a systemic right ventricle; in the majority of patients, HFpEF was associated to complex congenital heart defects (n = 18). Mean pulmonary arterial pressures (PAP systolic/diastolic) were 56/28 (± 24/13), left atrial pressures (LAP, v-, a-wave, mean) 26/25/20 (± 7/10/6). Trans-septal puncture was used in 22 patients; foramen ovale dilatation in 2 patients. Median balloon size was 12 (range 6-18) mm; procedure time including diagnostic measures 125 (83-221) min. No procedural death or complications were observed. Mean LA-pressures decreased significantly to 19/19/15 ± 6/8/5 mmHg (p = 0.05); median brain natriuretic peptide (BNP) decreased from 392 (range 93-4401) pg/ml median BNP to 314 (range 61-1544) pg/ml (p = 0.05). Three patients died; one patient received orthotopic heart and one patient a heart-lung transplantation. No patient required so far an assist device. Clinical improvement occurred in all patients, in some after additional surgical or interventional approach. Transcatheter LA decompression is an age-independent, effective palliation treating patients with HFpEF.

  8. The β3 Adrenergic Receptor Agonist BRL37344 Exacerbates Atrial Structural Remodeling Through iNOS Uncoupling in Canine Models of Atrial Fibrillation.

    Science.gov (United States)

    Wang, Xiaobing; Wang, Ruifeng; Liu, Guangzhong; Dong, Jingmei; Zhao, Guanqi; Tian, Jingpu; Sun, Jiayu; Jia, Xiuyue; Wei, Lin; Wang, Yuping; Li, Weimin

    2016-01-01

    The role of the β3-adrenergic receptor (β3-AR) agonist BRL37344 in atrial fibrillation (AF) structural remodeling and the underlying mechanisms as a therapeutic target were investigated. Four groups of dogs were evaluated: sham, pacing, β3-AR agonist BRL37344 (β3-AGO), and β3-AR antagonist L748337 (β3-ANT) groups. Dogs in the pacing, β3-AGO and β3-ANT groups were subjected to rapid atrial pacing for four weeks. Atrial structure and function, AF inducibility and duration, atrial myocyte apoptosis and interstitial fibrosis were assessed. Atrial superoxide anions were evaluated by fluorescence microscopy and colorimetric assays. Cardiac nitrate+nitrite levels were used to assess nitric oxide (NO) production. Protein and mRNA expression of β3-AR, neuronal NO synthase (nNOS), inducible NO synthase (iNOS), endothelial NO synthase (eNOS) and guanosine triphosphate cyclohydrolase-1 (GCH-1) as well as tetrahydrobiopterin (BH4) levels were measured. β3-AR was up-regulated in AF. Stimulation of β3-AR significantly increased atrial myocyte apoptosis, fibrosis and atrial dilatation, resulting in increased AF induction and prolonged duration. These effects were attenuated by β3-ANT. Moreover, β3-AGO reduced BH4 and NO production and increased superoxide production, which was inhibited by the specific iNOS inhibitor, 1400w β3-AGO also increased iNOS but decreased eNOS and had no effect on nNOS expression in AF. β3-AR stimulation resulted in atrial structural remodeling by increasing iNOS uncoupling and related oxidative stress. β3-AR up-regulation and iNOS uncoupling might be underlying AF therapeutic targets. © 2016 The Author(s) Published by S. Karger AG, Basel.

  9. Oclusão percutânea do apêndice atrial esquerdo com o Amplatzer Cardiac PlugTM na fibrilação atrial Percutaneous occlusion of left atrial appendage with the Amplatzer Cardiac PlugTM in atrial fibrillation

    Directory of Open Access Journals (Sweden)

    Márcio José Montenegro

    2012-02-01

    , anticoagulation has several limitations and has been widely underutilized. Over 90% of thrombi identified in patients with atrial fibrillation without valvular disease originate in the left atrial appendage, whose occlusion is investigated as an alternative to anticoagulation. Objective: To determine the feasibility of percutaneous occlusion of the left atrial appendage in patients at high risk of embolic events and limitations to the use of anticoagulation. Methods: We report our initial experience with Amplatzer Cardiac PlugTM (St. Jude Medical Inc., Saint Paul, Estados Unidos in patients with nonvalvular atrial fibrillation. We selected patients at high risk of thromboembolism, major bleeding, contraindications to the use or major instability in response to the anticoagulant. The procedures were performed percutaneously under general anesthesia and transesophageal echocardiography. The primary outcome was the presence of periprocedural complications and follow-up program included clinical and echocardiographic review within 30 days and by telephone contact after nine months. Results: In five selected patients it was possible to occlude the left atrial appendage without periprocedural complications. There were no clinical events in follow-up. Conclusion: Controlled clinical trials are needed before percutaneous closure of the left atrial appendage should be considered an alternative to anticoagulation in nonvalvular atrial fibrillation. But the device has shown to be promissory in patients at high risk of embolism and restrictions on the use of anticoagulants.

  10. Fully automatic segmentation of left atrium and pulmonary veins in late gadolinium-enhanced MRI: Towards objective atrial scar assessment.

    Science.gov (United States)

    Tao, Qian; Ipek, Esra Gucuk; Shahzad, Rahil; Berendsen, Floris F; Nazarian, Saman; van der Geest, Rob J

    2016-08-01

    To realize objective atrial scar assessment, this study aimed to develop a fully automatic method to segment the left atrium (LA) and pulmonary veins (PV) from late gadolinium-enhanced (LGE) magnetic resonance imaging (MRI). The extent and distribution of atrial scar, visualized by LGE-MRI, provides important information for clinical treatment of atrial fibrillation (AF) patients. Forty-six AF patients (age 62 ± 8, 14 female) who underwent cardiac MRI prior to RF ablation were included. A contrast-enhanced MR angiography (MRA) sequence was acquired for anatomy assessment followed by an LGE sequence for LA scar assessment. A fully automatic segmentation method was proposed consisting of two stages: 1) global segmentation by multiatlas registration; and 2) local refinement by 3D level-set. These automatic segmentation results were compared with manual segmentation. The LA and PVs were automatically segmented in all subjects. Compared with manual segmentation, the method yielded a surface-to-surface distance of 1.49 ± 0.65 mm in the LA region when using both MRA and LGE, and 1.80 ± 0.93 mm when using LGE alone (P automatic and manual segmentation was comparable to the interobserver difference (P = 0.8 in LA region and P = 0.7 in PV region). We developed a fully automatic method for LA and PV segmentation from LGE-MRI, with comparable performance to a human observer. Inclusion of an MRA sequence further improves the segmentation accuracy. The method leads to automatic generation of a patient-specific model, and potentially enables objective atrial scar assessment for AF patients. J. Magn. Reson. Imaging 2016;44:346-354. © 2016 Wiley Periodicals, Inc.

  11. Heart-specific overexpression of (pro)renin receptor induces atrial fibrillation in mice.

    Science.gov (United States)

    Lian, Hong; Wang, Xiaojian; Wang, Juan; Liu, Ning; Zhang, Li; Lu, Yingdong; Yang, Yanmin; Zhang, Lianfeng

    2015-04-01

    Atrial fibrillation (AF) is the most common cardiac arrhythmia, causing substantial cardiovascular morbidity and mortality. The renin-angiotensin system (RAS) has been shown to be involved in the pathophysiology of AF. The (pro)renin receptor [(p)RR] is the last identified member of RAS. However, the role of (p)RR in AF is still unknown. Circulating levels of (p)RR were determined using an immunosorbent assay in 22 patients with AF (paroxysmal or persistent) and 22 healthy individuals. The plasma levels of (p)RR increased 3.6-fold in AF patients (Patrial flutter since 2 months, then spontaneously converted to atrial fibrillation by 10 months. The atria of the transgenic mice demonstrated significant dilation and fibrosis, and exhibited a high incidence of sudden death. Additionally, the genes of SERCA and HCN4, which are involved in the electrophysiology of AF, were significantly down-regulated and up-regulated respectively in transgenic mice atria. The phosphorylation of Erk1/2 significantly increased in the atria of the transgenic mice, and the activated Erk1/2 was found predominantly in cardiac fibroblasts, suggesting that the transgenic (p)RR gene may induce atrial fibrillation by activation of Erk1/2 in the cardiac fibroblasts of the atria. (p)RR promotes atrial structural and electrical remodeling in vivo, which indicates that (p)RR plays an important role in the pathological development of AF. Copyright © 2015. Published by Elsevier Ireland Ltd.

  12. Usefulness of left ventricular speckle tracking echocardiography and novel measures of left atrial structure and function in diagnosing paroxysmal atrial fibrillation in ischemic stroke and transient ischemic attack patients.

    Science.gov (United States)

    Skaarup, Kristoffer Grundtvig; Christensen, Hanne; Høst, Nis; Mahmoud, Masti Mahdy; Ovesen, Christian; Olsen, Flemming Javier; Jensen, Jan Skov; Biering-Sørensen, Tor

    2017-12-01

    Asymptomatic paroxysmal atrial fibrillation (PAF) is often assumed to be the cause of cryptogenic ischemic strokes (IS) and transient ischemic attacks (TIA). We examined the usefulness of measures obtained by 2D speckle tracking echocardiography and novel left atrial measurements, in the diagnosis of PAF in patients with IS and TIA. We retrospectively included 205 patients who after acute IS or TIA underwent an echocardiogram in sinus rhythm. Patients were designated as PAF-patients if they had one or more reported incidents of AF before or after their echocardiographic examination. None of the conventional echocardiographic parameters were significantly associated with PAF. Of the speckle tracking measurements, only early diastolic strain rate (0.7±0.2 s -1 vs. 0.8±0.3 s -1 , p = 0.048) and global longitudinal displacement (GLD) (3.15 ± 1.40 mm vs. 3.87 ± 1.56 mm, p = 0.007) proved significantly different. Of the left atrial parameters both minimal and maximal left atrium volume divided by left ventricular length (min LAV/LVL and max LAV/LVL, respectively) were significantly impaired (min LAV/LVL: 3.7 ± 2.1 cm 2 vs. 2.8 ± 1.11 cm 2 , p = 0.012; max LAV/LVL: 6.6 ± 3.1 cm 2 vs. 5.6 ± 1.7 cm 2 , p = 0.012). GLD, min max LAV/LVL proved significant after adjustment for age, gender, CHA 2 DS 2 -VASc and NIHSS. By combining information regarding age, GLD, min and max LAV/LVL the diagnostic accuracy of PAF improved, resulting in a significantly increased area under the curve (p = 0.037). In patients with IS and TIA GLD, min and max LAV/LVL were independently associated with the presence of PAF.

  13. Association of pulse pressure with new-onset atrial fibrillation in patients with hypertension and left ventricular hypertrophy

    DEFF Research Database (Denmark)

    Larstorp, Anne Cecilie K; Ariansen, Inger; Gjesdal, Knut

    2012-01-01

    , and mean arterial pressure. When evaluated in the same model, the predictive effect of systolic and diastolic blood pressures together was similar to that of PP. In this population of patients with hypertension and left ventricular hypertrophy, PP was the strongest single blood pressure predictor of new......Previous studies have found pulse pressure (PP), a marker of arterial stiffness, to be an independent predictor of atrial fibrillation (AF) in general and hypertensive populations. We examined whether PP predicted new-onset AF in comparison with other blood pressure components in the Losartan...... Intervention For Endpoint reduction in hypertension study, a double-blind, randomized (losartan versus atenolol), parallel-group study, including 9193 patients with hypertension and electrocardiographic left ventricular hypertrophy. In 8810 patients with neither a history of AF nor AF at baseline, Minnesota...

  14. Isolated persistent left-sided superior vena cava, giant coronary sinus, atrial tachycardia and heart failure in a child

    Directory of Open Access Journals (Sweden)

    Nagaraja Moorthy

    2013-09-01

    Full Text Available Persistence of a left-sided superior vena cava (PLSVC with absent right superior vena cava (isolated PLSVC is a very rare venous malformation and commonly associated with congenital heart disease or alterations of the cardiac situs. We describe an unusual case of a young boy presenting with persistent atrial tachycardia and congestive heart failure. He was detected to have unexplained grossly dilated right atrium, right ventricle with systolic dysfunction and a giant coronary sinus (CS. The dilated CS closely mimicked a pseudo cor-triatriatum on echocardiography. Contrast echocardiography from both arms revealed opacification of the CS before the right atrium. Bilateral upper limb venography confirmed the presence of absent right SVC and isolated persistent left SVC draining into the giant coronary sinus.

  15. Left atrial volume index is an independent predictor of hypertensive response to exercise in patients with hypertension.

    Science.gov (United States)

    Lee, Sang-Eun; Youn, Jong-Chan; Lee, Hye Sun; Park, Sungha; Lee, Sang-Hak; Cho, In-Jeong; Shim, Chi Young; Hong, Geu-Ru; Choi, Donghoon; Kang, Seok-Min

    2015-02-01

    A hypertensive response to exercise (HRE) is known to be associated with higher risk of heart failure and future cardiovascular events in patients with hypertension. Left atrial volume index (LAVI) is associated with the diastolic dysfunction, indicating exercise intolerance. Therefore, we investigated whether LAVI is relevant to HRE during cardiopulmonary exercise test (CPET). We studied 118 consecutive hypertensive patients (61 men, 57±11 years) and 45 normotensive control subjects (16 men, 54±8 years). Clinical characteristics, CPET, echocardiographic and laboratory findings were assessed at the time of enrollment. HRE was defined as maximum systolic blood pressure (SBP)⩾210 mm Hg in men and ⩾190 mm Hg in women. HRE was more prevalent in hypertensive patients compared with normotensive control subjects (50.8% vs. 20.0%, PHRE in normotensive control subjects, as were baseline SBP and LAVI in hypertensive group. In multivariate analysis, LAVI was found to be an independent predictor of HRE in hypertensive patients (P=0.020) but not in normotensive control subjects (P=0.936) when controlled for age, sex, body mass index and peak oxygen consumption. Higher LAVI, reflecting the duration and severity of increased left atrial pressure is independently associated with HRE in hypertensive patients, but not in normotensive control subjects.

  16. Adding left atrial appendage closure to open heart surgery provides protection from ischemic brain injury six years after surgery independently of atrial fibrillation history: the LAACS randomized study.

    Science.gov (United States)

    Park-Hansen, Jesper; Holme, Susanne J V; Irmukhamedov, Akhmadjon; Carranza, Christian L; Greve, Anders M; Al-Farra, Gina; Riis, Robert G C; Nilsson, Brian; Clausen, Johan S R; Nørskov, Anne S; Kruuse, Christina R; Rostrup, Egill; Dominguez, Helena

    2018-05-23

    Open heart surgery is associated with high occurrence of atrial fibrillation (AF), subsequently increasing the risk of post-operative ischemic stroke. Concomitant with open heart surgery, a cardiac ablation procedure is commonly performed in patients with known AF, often followed by left atrial appendage closure with surgery (LAACS). However, the protective effect of LAACS on the risk of cerebral ischemia following cardiac surgery remains controversial. We have studied whether LAACS in addition to open heart surgery protects against post-operative ischemic brain injury regardless of a previous AF diagnosis. One hundred eighty-seven patients scheduled for open heart surgery were enrolled in a prospective, open-label clinical trial and randomized to concomitant LAACS vs. standard care. Randomization was stratified by usage of oral anticoagulation (OAC) planned to last at least 3 months after surgery. The primary endpoint was a composite of post-operative symptomatic ischemic stroke, transient ischemic attack or imaging findings of silent cerebral ischemic (SCI) lesions. During a mean follow-up of 3.7 years, 14 (16%) primary events occurred among patients receiving standard surgery vs. 5 (5%) in the group randomized to additional LAACS (hazard ratio 0.3; 95% CI: 0.1-0.8, p = 0.02). In per protocol analysis (n = 141), 14 (18%) primary events occurred in the control group vs. 4 (6%) in the LAACS group (hazard ratio 0.3; 95% CI: 0.1-1.0, p = 0.05). In a real-world setting, LAACS in addition to elective open-heart surgery was associated with lower risk of post-operative ischemic brain injury. The protective effect was not conditional on AF/OAC status at baseline. LAACS study, clinicaltrials.gov NCT02378116 , March 4th 2015, retrospectively registered.

  17. Low Left Atrial Compliance Contributes to the Clinical Recurrence of Atrial Fibrillation after Catheter Ablation in Patients with Structurally and Functionally Normal Heart.

    Science.gov (United States)

    Park, Junbeom; Yang, Pil-sung; Kim, Tae-Hoon; Uhm, Jae-Sun; Kim, Joung-Youn; Joung, Boyoung; Lee, Moon-Hyoung; Hwang, Chun; Pak, Hui-Nam

    2015-01-01

    Stiff left atrial (LA) syndrome was initially reported in post-cardiac surgery patients and known to be associated with low LA compliance. We investigated the physiological and clinical implications of LA compliance by estimating LA pulse pressure (LApp) among patients with atrial fibrillation (AF) and structurally and functionally normal heart. Among 1038 consecutive patients with LA pressure measurements before AF ablation, we included 334 patients with structurally and functionally normal heart (81.7% male, 54.1±10.6 years, 77.0% paroxysmal AF) after excluding those with hypertension, diabetes, and previous ablation or cardiac surgery. We measured LApp (peak-nadir LA pressure) at the beginning of the ablation procedure and compared the values with clinical parameters and the AF recurrence rate. AF patients with normal heart were younger and more frequently male and had paroxysmal AF, a lower body mass index, and a lower LApp compared to others (all p<0.05). Based on the median value, the low LA compliance group (LApp≥13 mmHg) had a smaller LA volume index and lower LA voltage (all p<0.05) compared to the high LA compliance group. During a mean follow-up of 16.7±11.8 months, low LA compliance was independently associated with two fold-higher risk of clinical AF recurrence (HR:2.202; 95%CI:1.077-4.503; p = 0.031). Low LA compliance, as determined by an elevated LApp, was associated with a smaller LA volume index and lower LA voltage and independently associated with higher clinical recurrence after catheter ablation in AF patients with structurally and functionally normal heart.

  18. Left atrial appendage occlusion for stroke prevention in patients with atrial fibrillation: a systematic review and network meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Hanif, Hasib; Belley-Cote, Emilie P; Alotaibi, Abdullah; Dvirnik, Nazari; Neupane, Binod; Beyene, Joseph; Eikelboom, John W; Holmes, David; Whitlock, Richard P

    2018-02-01

    Atrial fibrillation (AF) is one of the leading causes of stroke. Risks associated with oral anticoagulation (OAC) limit adherence to recommended therapy. Left atrial appendage (LAA) occlusion is a treatment alternative in patients with AF. We performed a network meta-analysis (NMA) of randomized trials evaluating the efficacy of LAA occlusion compared with oral anticoagulant, antiplatelet, and placebo for stroke prevention. We also assessed the impact of LAA occlusion on mortality, major bleeding, and operative time. We searched MEDLINE, EMBASE, PubMed, and Cochrane Library for randomized trials comparing percutaneous or surgical LAA occlusion with standard of care in AF patients. Conventional meta-analysis found no difference between groups for stroke (5 trials, 1285 patients;RR 0.78, 95% CI 0.47-1.29), and a significant reduction in mortality (5 trials, 1285 patients; RR 0.71, 95% CI 0.51-0.99) favouring LAA occlusion. NMA demonstrated a trend towards reduction in stroke (OR 0.84, 95% CrI 0.47-1.55) and mortality (OR 0.69, 95% CrI 0.44-1.10) for LAA occlusion versus warfarin, but no statistically significant effect. Statistical ranking curves placed LAA occlusion as the most efficacious treatment on the outcomes of stroke and mortality when compared to warfarin, aspirin, or placebo. No significant differences between groups were seen in major bleeding or operative time for surgical trials. The overall quality of the evidence was low as assessed by GRADE. LAA occlusion appears to preserve the benefits of OAC therapy for stroke prevention in patients with AF, but the current evidence is of low quality.

  19. Oclusão do apêndice atrial esquerdo com o Amplatzer Cardiac Plug em pacientes com fibrilação atrial Left atrial appendage closure with the Amplatzer Cardiac Plug in patients with atrial fibrillation

    Directory of Open Access Journals (Sweden)

    Ênio Eduardo Guérios

    2012-06-01

    Full Text Available FUNDAMENTO: A oclusão percutânea do apêndice atrial esquerdo (OAAE surgiu como alternativa à anticoagulação oral (AO para prevenção do acidente vascular cerebral (AVC em pacientes com fibrilação atrial não-valvular (FANV. OBJETIVO: Relatar os resultados imediatos e o seguimento clínico de pacientes submetidos a OAAE com o Amplatzer Cardiac Plug (ACP em um único centro de referência. MÉTODOS: Oitenta e seis pacientes consecutivos com FANV, contra-indicação à AO e escore CHADS2= 2,6±1,2 foram submetidos a OAAE com implante de ACP. Realizou-se seguimento clínico e ecocardiográfico no mínimo 4 meses após o implante. RESULTADOS: Todos os implantes foram guiados apenas por angiografia. O sucesso do procedimento foi de 99% (1 insucesso por tamponamento cardíaco e consequente suspensão da OAAE. Houve 4 complicações maiores (o tamponamento já referido, 2 AVCs transitórios e uma embolização com retirada percutânea da prótese e duas menores (um derrame pericárdico sem tamponamento e uma pequena comunicação interatrial evidenciada no seguimento. Houve 1 óbito hospitalar após 6 dias, não relacionado à intervenção. Todos os outros pacientes receberam alta sem AO. Após seguimento de 25,9 pacientes-ano (69 pacientes não houve AVCs nem embolizações tardias de próteses. O AAE estava completamente ocluído em 97% dos casos. Seis pacientes apresentaram evidência de trombo sobre a prótese, que desapareceram após reinstituição de AO por 3 meses. CONCLUSÃO: OAAE se associa a um alto índice de sucesso, um índice aceitável de complicações e resultados promissores a médio prazo, podendo ser considerada uma alternativa válida à OA na prevenção do AVC em pacientes com FANV.BACKGROUND: Percutaneous left atrial appendage closure (LAAC has emerged as an alternative to oral anticoagulation (OA for prevention of thromboembolic stroke in patients with non-valvular atrial fibrillation (NVAF. OBJECTIVE: To describe the

  20. Efficiency evaluation of treatment of atrial rhythm disorders on the left ventricular function

    International Nuclear Information System (INIS)

    Alberini, J.L.; Mansour, H.; Victor, F.; De Place, C.; Carre, F.; Daubert, J.C.; Borguet, P.

    1997-01-01

    The goal of this prospective study was to evaluate the development and evolution of the LV function after treatment of atrial arrhythmias, evolving for at least three months, associated to an alteration of the LV function. Twelve patients (61.3 ± 13.9 years) were divided into two groups: Gr1 - treatment by cardio-version or radiofrequency; Gr2 - pharmacological treatment or ablation of atrial-ventricular junction and implantation of a cardiac pacemaker. An examination including ECG, Holter, test-to-effort, echocardiography, cavitary angio-scintigraphy was effectuated 48 h and 6 weeks after reduction. A net clinic amelioration was observed in the evolution, confirmed by results of the echocardiographic and angio-scintigraphic examinations (with a correlation coefficient of 0.87). In exchange, between the two examinations, there is no significant difference for the test-to-effort with medium or maximal cardiac frequencies and the diameters or tele-diastolic and tele-systolic volumes for echography. After the multi-variable analysis the initial angio-scintigraphic measurement of the LV function is a good predictive factor in ameliorating the LV function in patients maintained in sinusal rhythm. In conclusion, the angio-scintigraphy permits predicting the treatment efficiency of the atrial arrhythmias on the LV function

  1. Left ventricular dysfunction in repaired tetralogy of Fallot: incidence and impact on atrial arrhythmias at long term-follow up.

    Science.gov (United States)

    Ait Ali, Lamia; Trocchio, GianLuca; Crepaz, Roberto; Stuefer, Josef; Stagnaro, Nicola; Siciliano, Valeria; Molinaro, Sabrina; Sicari, Rosa; Festa, Pierluigi

    2016-09-01

    Left ventricle (LV) systolic dysfunction in repaired tetralogy of Fallot (TOF) has been identified as a risk factor for functional status and adverse outcome. The aims of this cross-sectional followed by a prospective study were: (1) to evaluate the prevalence of LV systolic dysfunction in a large cohort of adults with repaired tetralogy of Fallot, (2) to test the relationship between LV systolic dysfunction and other known risk factors and (3) to evaluate the impact of LV systolic dysfunction on adverse cardiac events. In a multicenter study, 237 adults repaired TOF (58 % males, age 30 ± 10 years) were evaluated by cardiac magnetic resonance (CMR). Demographics, surgical history, ECG, Echo-Color Doppler and follow-up data were recorded. LV was dilated (Z value >2) in 16 patients (6 %), however 56 patients (23.6 %) had a reduced LV systolic function left ventricle ejection fraction (LVEF) (Z value <-2). Patients with LV systolic dysfunction were mainly males (82 %), had reduced right ventricle ejection fraction (RVEF), and higher right and left Late Gadolinium Enhanced scores. In a multivariate regression analysis male gender and RVEF resulted to be independent factors associated to LV systolic dysfunction. Atrial arrhythmias were the main adverse cardiac event at the follow-up and were associated to higher biventricular volumes and lower biventricular ejection fraction (EF); however multivariable analysis identified age, right ventricle end-diastolic volume (RVEDVi) and tricuspid regurgitation as independents factors associated to atrial arrhythmias. At long term follow-up at least ¼ of repaired TOF has LV dysfunction. Lower LVEF is associated to male gender and lower RVEF.

  2. Associations of electrocardiographic P-wave characteristics with left atrial function, and diffuse left ventricular fibrosis defined by cardiac magnetic resonance: The PRIMERI Study.

    Science.gov (United States)

    Tiffany Win, Theingi; Ambale Venkatesh, Bharath; Volpe, Gustavo J; Mewton, Nathan; Rizzi, Patricia; Sharma, Ravi K; Strauss, David G; Lima, Joao A; Tereshchenko, Larisa G

    2015-01-01

    Abnormal P-terminal force in lead V1 (PTFV1) is associated with an increased risk of heart failure, stroke, atrial fibrillation, and death. Our goal was to explore associations of left ventricular (LV) diffuse fibrosis with left atrial (LA) function and electrocardiographic (ECG) measures of LA electrical activity. Patients without atrial fibrillation (n = 91; mean age 59.5 years; 61.5% men; 65.9% white) with structural heart disease (spatial QRS-T angle ≥105° and/or Selvester QRS score ≥5 on ECG) but LV ejection fraction >35% underwent clinical evaluation, cardiac magnetic resonance, and resting ECG. LA function indices were obtained by multimodality tissue tracking using 2- and 4-chamber long-axis images. T1 mapping and late gadolinium enhancement were used to assess diffuse LV fibrosis and presence of scar. P-prime in V1 amplitude (PPaV1) and duration (PPdV1), averaged P-wave-duration, PR interval, and P-wave axis were automatically measured using 12 SLTM algorithm. PTFV1 was calculated as a product of PPaV1 and PPdV1. In linear regression after adjustment for demographic characteristics, body mass index, maximum LA volume index, presence of scar, and LV mass index, each decile increase in LV interstitial fibrosis was associated with 0.76 mV*ms increase in negative abnormal PTFV1 (95% confidence interval [CI] -1.42 to -0.09; P = .025), 15.3 ms prolongation of PPdV1 (95% CI 6.9 to 23.8; P = .001) and 5.4 ms prolongation of averaged P-duration (95% CI 0.9-10.0; P = .020). LV fibrosis did not affect LA function. PPaV1 and PTFV1 were associated with an increase in LA volumes and decrease in LA emptying fraction and LA reservoir function. LV interstitial fibrosis is associated with abnormal PTFV1, prolonged PPdV1, and P-duration, but does not affect LA function. Copyright © 2015 Heart Rhythm Society. All rights reserved.

  3. [Stroke. are there any difference between patients with or without patent foramen ovale in left atrial appendage systolic function?].

    Science.gov (United States)

    Contreras, Alejandro E; Perrote, Federico; Concari, Ignacio; Brenna, Eduardo J; Lucero, Cecilia

    2012-01-01

    The aim of this study was to evaluate the systolic function of the left atrial appendage (LAA) in a group with and without patent foramen ovale (PFO) who suffered ischemic cerebrovascular events. Between September 2010 and October 2011, 17 patients were referred for transesophageal echocardiography (TEE) after suffering a stroke. PFO was defined as the passage of at least one bubble through atrial septum with bubble test. We compared systolic velocity in the appendage between patients with and without PFO and a control group. Were 8 women and 9 men, mean age 54.1 ± 19.5 years and 8 patients were under 55 years of age. All patients had suffered a ischemic cerebrovascular events, 41.2% had stroke, 52.9% transient ischemic attack and amaurosis fugax 5.9%. In the assessment of TEE, 11.8% had atrial septal aneurysm and 35.3% PFO. Mean LAA systolic velocity was 66.3 ± 20.3 cm / sec. There was no difference in systolic velocity of the LAA between patients with and without PFO (67.5 ± 11.8 cm / sec vs 65.7 ± 24.3 cm / sec respectively, p = 0.87). The control group of 8 patients, 5 women and 3 men, mean age 39.5 ± 18 years, had a LAA systolic velocity of 77.6 ± 28.9 cm / sec, no significant differences with ischemic patients. There were no differences in systolic function of the LAA between patients with and without PFO with ischemic cerebrovascular event.

  4. Epicardial clip occlusion of the left atrial appendage during cardiac surgery provides optimal surgical results and long-term stability.

    Science.gov (United States)

    Kurfirst, Vojtech; Mokrácek, Aleš; Canádyová, Júlia; Frána, Radim; Zeman, Petr

    2017-07-01

    Occlusion of the left atrial appendage (LAA) has become an integral and important part of the surgical treatment of atrial fibrillation. Different methods of surgical occlusion of the LAA have been associated with varying levels of short- and long-term success for closure. The purpose of this study was to evaluate long-term results of epicardial placement and endocardial occlusion in patients undergoing cardiac operative procedures. A total of 101 patients (average age 65.7 years) undergoing cardiac operative procedures with the epicardial AtriClip Exclusion System of the LAA were enrolled in the study. The AtriClip was placed via a sternotomy or a thoracotomy or from a thoracoscopic approach. Postoperative variables, such as thromboembolic events, clip stability and endocardial leakage around the device, were examined by transoesophageal echocardiography (TEE) and/or computed tomography. Perioperative clip implantation was achieved in 98% of patients. TEE and/or computed tomography conducted during the follow-up period, comprising 1873 patient-months with a mean duration of 18 ± 11 months, revealed no clip migration, no leakage around the device and no clot formation near the remnant cul-de-sac. During the follow-up period, 4 of the cardiac patients experienced transitory ischaemic attacks, whereas no patient experienced a cerebrovascular attack. The Epicardial AtriClip Exclusion System of the LAA appears to be a feasable and safe operative method with a high success rate. Long-term follow-up confirmed clip stability, complete occlussion of the LAA and absence of any atrial fibrilation-related thromboembolic events. These results need to be confirmed by a larger, multicentre study. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  5. A stochastic approach for automatic registration and fusion of left atrial electroanatomic maps with 3D CT anatomical images

    International Nuclear Information System (INIS)

    Cristoforetti, Alessandro; Mase, Michela; Faes, Luca; Centonze, Maurizio; Greco, Maurizio Del; Antolini, Renzo; Nollo, Giandomenico; Ravelli, Flavia

    2007-01-01

    The integration of electroanatomic maps with highly resolved computed tomography cardiac images plays an important role in the successful planning of the ablation procedure of arrhythmias. In this paper, we present and validate a fully-automated strategy for the registration and fusion of sparse, atrial endocardial electroanatomic maps (CARTO maps) with detailed left atrial (LA) anatomical reconstructions segmented from a pre-procedural MDCT scan. Registration is accomplished by a parameterized geometric transformation of the CARTO points and by a stochastic search of the best parameter set which minimizes the misalignment between transformed CARTO points and the LA surface. The subsequent fusion of electrophysiological information on the registered CT atrium is obtained through radial basis function interpolation. The algorithm is validated by simulation and by real data from 14 patients referred to CT imaging prior to the ablation procedure. Results are presented, which show the validity of the algorithmic scheme as well as the accuracy and reproducibility of the integration process. The obtained results encourage the application of the integration method in post-intervention ablation assessment and basic AF research and suggest the development for real-time applications in catheter guiding during ablation intervention

  6. Transcatheter treatment of heart failure with preserved or mildly reduced ejection fraction using a novel interatrial implant to lower left atrial pressure

    DEFF Research Database (Denmark)

    Søndergaard, Lars; Reddy, Vivek; Kaye, David

    2014-01-01

    BACKGROUND: Heart failure with preserved or mildly reduced ejection fraction (HFpEF) is common and, to date, therapeutic options are limited. Increased left atrial pressure is a key contributor to the symptoms associated with HFpEF, particularly during physical activity. We report the 30-day...... outcome of patients treated with a novel device intended to lower left atrial pressure by creating an 8 mm permanent shunt in the atrial septum. METHODS AND RESULTS: Eleven patients were enrolled in the pilot trial. Key inclusion criteria were: EF >45%; baseline PCWP ≥15 mmHg (rest), or ≥ 25 mm...... patients, one class in five patients, and worsened by one class in one patient. No patient developed pulmonary hypertension. Two serious adverse events occurred; heart failure re-hospitalization, and implant malposition successfully treated with a new device. CONCLUSION: Contemporary management of HFp...

  7. Incidence of atrial fibrillation in patients with either heart failure or acute myocardial infarction and left ventricular dysfunction: a cohort study

    DEFF Research Database (Denmark)

    Schmiegelow, Michelle D; Pedersen, Ole D; Køber, Lars

    2011-01-01

    We examined the incidence of new-onset atrial fibrillation in patients with left ventricular dysfunction. Patients either had a recent myocardial infarction (with or without clinical heart failure) or symptomatic heart failure (without a recent MI). Patients were with and without treatment...

  8. Autonomic dysfunction and new-onset atrial fibrillation in patients with left ventricular systolic dysfunction after acute myocardial infarction: a CARISMA substudy

    DEFF Research Database (Denmark)

    Jøns, Christian; Raatikainen, Pekka; Gang, Uffe J

    2010-01-01

    Atrial fibrillation (AF) increases morbidity and mortality in patients with previous myocardial infarction and left ventricular systolic dysfunction. The purpose of this study was to identify patients with a high risk for new-onset AF in this population using invasive and noninvasive...

  9. Previously known and newly diagnosed atrial fibrillation: a major risk indicator after a myocardial infarction complicated by heart failure or left ventricular dysfunction

    DEFF Research Database (Denmark)

    Køber, Lars; Swedberg, Karl; McMurray, John J V

    2006-01-01

    AIMS: To characterize the relationship between known and newly diagnosed atrial fibrillation (AF) and the risk of death and major cardiovascular (CV) events in patients with acute myocardial infarction (MI) complicated by heart failure (HF) and/or left ventricular systolic dysfunction (LVSD). MET...

  10. The Impact of Atrial Left-to-Right Shunt on Pulmonary Hypertension in Preterm Infants with Moderate or Severe Bronchopulmonary Dysplasia

    Directory of Open Access Journals (Sweden)

    Eui Kyung Choi

    2015-10-01

    Conclusion: The presence of an atrial left-to-right shunt was associated with PH in preterm infants with moderate or severe BPD. Close follow up is needed for infants with interatrial shunts, and a more tailored prognostic evaluation and treatment are recommended.

  11. Predicting Peri-Device Leakage of Left Atrial Appendage Device Closure Using Novel Three-Dimensional Geometric CT Analysis.

    Science.gov (United States)

    Chung, Hyemoon; Jeon, Byunghwan; Chang, Hyuk-Jae; Han, Dongjin; Shim, Hackjoon; Cho, In Jeong; Shim, Chi Young; Hong, Geu-Ru; Kim, Jung-Sun; Jang, Yangsoo; Chung, Namsik

    2015-12-01

    After left atrial appendage (LAA) device closure, peri-device leakage into the LAA persists due to incomplete occlusion. We hypothesized that pre-procedural three-dimensional (3D) geometric analysis of the interatrial septum (IAS) and LAA orifice can predict this leakage. We investigated the predictive parameters of LAA device closure obtained from baseline cardiac computerized tomography (CT) using a novel 3D analysis system. We conducted a retrospective study of 22 patients who underwent LAA device closure. We defined peri-device leakage as the presence of a Doppler signal inside the LAA after device deployment (group 2, n = 5) compared with patients without peri-device leakage (group 1, n = 17). Conventional parameters were measured by cardiac CT. Angles θ and φ were defined between the IAS plane and the line, linking the LAA orifice center and foramen ovale. Group 2 exhibited significantly better left atrial (LA) function than group 1 (p = 0.031). Pre-procedural θ was also larger in this group (41.9° vs. 52.3°, p = 0.019). The LAA cauliflower-type morphology was more common in group 2. Overall, the patients' LA reserve significantly decreased after the procedure (21.7 mm(3) vs. 17.8 mm(3), p = 0.035). However, we observed no significant interval changes in pre- and post-procedural values of θ and φ in either group (all p > 0.05). Angles between the IAS and LAA orifice might be a novel anatomical parameter for predicting peri-device leakage after LAA device closure. In addition, 3D CT analysis of the LA and LAA orifice could be used to identify clinically favorable candidates for LAA device closure.

  12. Evaluation of left ventricular function in patients with atrial fibrillation by ECG gated blood pool scintigraphy. Analysis of left ventricular filling and function curve

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Suetsugu; Adachi, Haruhiko; Sugihara, Hiroki

    1985-12-01

    ECG gated blood pool scintigraphy (EGBP) is not always valid for the patients with atrial fibrillation (AF), since they have wide variability in cardiac cycle length (CL). To evaluate the left ventricular (LV) function during AF by EGBP, we devised a new processing algorithm to construct multiple gated images discriminated by preceding R-R interval (PRR) from the data acquired in list mode. 18 patients with AF were studied as to; 1) How affect the PRR on cardiac indices such as EF, TES, PER or TPER, 2) Comparison with conventional method getting all CL data, 3) LV filling curves derived by plotting EDV against PRR, 4) The slope and position of LV function curves (LVFC) derived by plotting SV against EDV. In most cases, EF, PER and TES were increased with longer PRR, and those by conventional method nearly corresponded to the average values obtained by our new method. Impairment of ventricular filling was demonstrated in the cases of mitral stenosis and constrictive pericarditis. LVFC of CHF group was situated at right and downward to controls, and left and upward shift was observed after treatment. The slope of LVFC was reduced in relation to the progression of NYHA's functional class. In conclusion, this new algorithm processing irregular CL enables LV filling and function curves to draw, which are useful in the evaluation of cardiac performance in the subjects with AF.

  13. Left ventricular ejection fraction and left atrium diameter related to new-onset atrial fibrillation following acute myocardial infarction: a systematic review and meta-analysis.

    Science.gov (United States)

    Zeng, Rui-Xiang; Chen, Mao-Sheng; Lian, Bao-Tao; Liao, Peng-Da; Zhang, Min-Zhou

    2017-10-06

    New-onset atrial fibrillation (NOAF) occurs frequently in patients with acute myocardial infarction (AMI), and is associated with increased subsequent cardiovascular mortality. However, only a few studies directly evaluated the relationship of left ventricular ejection fraction (LVEF) or left atrium diameter (LAD) and NOAF following AMI. MEDLINE ® , EMBASE ® and the Cochrane Library were carried out to find studies until January 2017. Pooled mean difference (MD) and 95% confidence interval (CI) were calculated to evaluate the value of LVEF and LAD in the prediction of NOAF after AMI. We performed sensitivity analyses to explore the potential sources of heterogeneity. Statistical analyses were carried out using the Revman 5.3. We included 10 qualifying studies comprising a total of 708 patients with NOAF and 6785 controls. Overall, decreased LVEF and increased LAD levels had a significant positive association with NOAF in patients with AMI. The MD in the LVEF levels between the patients with and those without NOAF was -4.91 units (95% Cl: -5.70 to -4.12), test for overall effect z-score = 12.18 ( p < 0.00001, I 2 = 35%). Moreover, in a subgroup analysis, the MD for LAD and NOAF was 2.55 units (95% Cl: 1.91 to 3.19), test for overall effect z-score = 7.80 ( p < 0.00001, I 2 = 57%). Our meta-analysis demonstrated that both decreased LVEF and increased LAD levels were associated with greater risk of NOAF following AMI.

  14. Relationship of CHA2DS2-VASc and CHADS2 score to left atrial remodeling detected by velocity vector imaging in patients with atrial fibrillation.

    Directory of Open Access Journals (Sweden)

    Yihui Li

    Full Text Available BACKGROUND: The CHADS2/CHA2DS2-VASc scores are used to predict thrombo-embolic/stroke in patients with nonvalvular atrial fibrillation (AF. Nevertheless, limited data are available regarding the association between these risk stratification for stroke and left atrial (LA remodeling status of AF patients. The purpose of this study was to explore the association between these scores and LA remodeling status assessed quantificationally by echocardiography in AF patients. METHODS: One hundred AF patients were divided into 3 groups based on the CHA2DS2-VASc/CHADS2 score: the score of 0 (low stroke risk, the score of 1 (moderate stroke risk and the score of ≥2 (high stroke risk. All patients were performed through conventional and velocity vector imaging echocardiography. Echocardiographic parameters: maximum LA volume index (LAVImax, LA total emptying fraction (LAEFt and LA mean strain were obtained to assess quantificationally LA remodeling status. RESULTS: On categorizing with CHA2DS2-VASc, the score of 1 group showed augment in LAVImax and attenuation in LA mean strain derived from VVI, compared with the score of 0 group (LAVImax: 40.27±21.91 vs. 26.79±7.87, p=0.002; LA mean strain: 15.18±6.36 vs. 22±8.54, p=0.001. On categorizing with the CHADS2 score, similar trends were seen between the score of ≥2 and 1 groups (LAVImax: 43.72±13.77 vs. 31.41±9.50, p<0.001; LA mean strain: 11.01±5.31 vs. 18.63±7.00, p<0.001. With multivariate logistic regression, LAVImax (odds ratio: 0.92 , 95% C=I: 0.85 to 0.98, p= 0.01 and LA mean strain reflecting LA remodeling (odds ratio: 1.10, 95% CI: 1.02 to 1.19, p=0.01 were strongly predictive of the CHA2DS2-VASc score of 0. CONCLUSIONS: The superiority of the CHADS2 score may lay in identifying LA remodeling of AF patients with high stroke risk. Whereas, the CHA2DS2-VASc score was better than the CHADS2 score at identifying LA remodeling of AF patients presenting low stroke risk.

  15. The application and value of 64 multislice spiral CT of left atrium and pulmonary vein in radio-frequency ablation of atrial fibrillation

    International Nuclear Information System (INIS)

    Guo Xi; Lv Biao; Zhang Zhaoqi; Zhao Yike; Jiang Hong; Ma Changsheng; Yu Ronghui; Wang Xue; Cao Hainian

    2008-01-01

    Objective: Analyzing the left atrium and pulmonary vein morphologically by 64 multislice spiral CT (MSCT) scan to guide the catheter ablation of Atrial fibrillation. Methods: Two hundred and thirty-two patients (146 cases in atrial fibrillation group and 86 cases in control group) received 64 MSCT examination of the left atrium and pulmonary vein. The incidence of anatomical variation of pulmonary vein was compared between atrial fibrillation group and control group. For each group, the anatomical morphology of every pulmonary vein and the auricle of left atrium was analyzed, the diameter of the orifice of each pulmonary vein and the size of left atrium were measured. Results: Sixty-four MSCT of left atrium and pulmonary vein could demonstrate detailed connecting type between left atrium and pulmonary veins and the possible anatomical variation. Anatomical variation of pulmonary vein in this study accounted for 16.8% (39/232) of total sample. For both groups, orifices of pulmonary veins appeared oval and their superoinferior diameters were larger than their anteroposterior diameters. There was significant difference in the inner diameter of left atrium between atrial fibrillation group and control group [atrial fibrillation group: (39.47 ± 8.98) mm, control group: (36.94±5.49) mm, P=0.02], while there was no difference in the diameters of orifices of pulmonary veins between two groups [superoinferior diameters of pulmonary veins in atrial fibrillation group: left-up (18.15±1.35) mm, left-down (16.96±1.18) mm, right-up (17.50±1.12) mm, fight-down (17.65±0.94) mm, superoinferior diameters of pulmonary veins in control group: left-up (18.07±0.94) mm, left-down (17.50±0.57) mm, right-up (18.03±1.02) mm, fight-down (17.94±0.76) mm, the corresponding P>0.05, respectively, anteroposterior diameters of pulmonary veins in atrial fibrillation group: left-up (12.26±1.89) mm, left-down (11.96±0.61) mm, right-up (12.32± 1.08) mm, fight-down (12.39±0.95) mm

  16. The Value of 3D Printing Models of Left Atrial Appendage Using Real-Time 3D Transesophageal Echocardiographic Data in Left Atrial Appendage Occlusion: Applications toward an Era of Truly Personalized Medicine.

    Science.gov (United States)

    Liu, Peng; Liu, Rijing; Zhang, Yan; Liu, Yingfeng; Tang, Xiaoming; Cheng, Yanzhen

    The objective of this study was to assess the clinical feasibility of generating 3D printing models of left atrial appendage (LAA) using real-time 3D transesophageal echocardiogram (TEE) data for preoperative reference of LAA occlusion. Percutaneous LAA occlusion can effectively prevent patients with atrial fibrillation from stroke. However, the anatomical structure of LAA is so complicated that adequate information of its structure is essential for successful LAA occlusion. Emerging 3D printing technology has the demonstrated potential to structure more accurately than conventional imaging modalities by creating tangible patient-specific models. Typically, 3D printing data sets are acquired from CT and MRI, which may involve intravenous contrast, sedation, and ionizing radiation. It has been reported that 3D models of LAA were successfully created by the data acquired from CT. However, 3D printing of the LAA using real-time 3D TEE data has not yet been explored. Acquisition of 3D transesophageal echocardiographic data from 8 patients with atrial fibrillation was performed using the Philips EPIQ7 ultrasound system. Raw echocardiographic image data were opened in Philips QLAB and converted to 'Cartesian DICOM' format and imported into Mimics® software to create 3D models of LAA, which were printed using a rubber-like material. The printed 3D models were then used for preoperative reference and procedural simulation in LAA occlusion. We successfully printed LAAs of 8 patients. Each LAA costs approximately CNY 800-1,000 and the total process takes 16-17 h. Seven of the 8 Watchman devices predicted by preprocedural 2D TEE images were of the same sizes as those placed in the real operation. Interestingly, 3D printing models were highly reflective of the shape and size of LAAs, and all device sizes predicted by the 3D printing model were fully consistent with those placed in the real operation. Also, the 3D printed model could predict operating difficulty and the

  17. Measurement of left atrial volume by 2D and 3D non-contrast computed tomography compared with cardiac magnetic resonance imaging

    DEFF Research Database (Denmark)

    Fredgart, Maise Høigaard; Carter-Storch, Rasmus; Møller, Jacob Eifer

    2018-01-01

    Background: Cardiac magnetic resonance imaging (MRI) is considered the gold standard for assessment of left atrial (LA) volume. We assessed the feasibility of evaluating LA volume using 3D non-contrast computed tomography (NCCT). Furthermore, since manual tracing of LA volume is time consuming, we...... evaluated the accuracy of the LA area using 2D NCCT imaging for LA volume assessment. Methods: MRI and NCCT imaging were performed in 69 patients before and one year after aortic valve replacement. In 3D MRI and 3D NCCT, each slice was manually traced, excluding the pulmonary veins and atrial appendage...

  18. MDCT Evaluation of Left Atrium and Pulmonary Vein in the Patients with Atrial Fibrillation: Comparison with the Non-Atrial Fibrillation Group

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Won Jung; Choi, Eun Jeong; Ham, Soo Yeon; Oh, Yu Whan; Kim, Young Hoon [Anam Hospital, Korea University College of Medicine, Seoul (Korea, Republic of); Yong, Hwan Seok [Korea University Guro Hospital, Seoul (Korea, Republic of); Yang, Kyung Sook [Korea University, Seoul (Korea, Republic of)

    2011-02-15

    The anatomy of the left atrium (LA) and the pulmonary veins (PVs) is important in planning and performing successful electrophysiologic ablation (EPA) for atrial fibrillation (Afib) patients. The authors estimated the findings of LA and PVs of Afib patients by MDCT, and compared these with the findings of LA and PVs of the non- Afib group using coronary CT angiography (CCTA). From September, 2009 to February, 2010, 91 Afib patients underwent PVCT (male: female = 72:19, mean age = 55.0-years-old) before EPA. At same time, 90 patients underwent CCTA (male: female = 73:17, mean age = 59.1- years-old). Two radiologists reviewed and analyzed all axial and 3D images of LA and PVs retrospectively with consensus. The average LA volumes of the Afib group(100.49 mm3) was larger than that of the non-Afib group (78.38 mm3) (p<0.05). The average lengths of the LA right wall in the Afib group (40.25 mm) was longer than that of the non-Afib group (37.3 mm) (p<0.05). The average distances between the PV ostium and first segmental bifurcation of the Lt superior PV (LSPV) and the RSPV were shorter in the Afib group (LSPV, 19.38 mm: RSPV, 11.49 mm) than in the non-Afib group (LSPV, 23.23 mm: RSPV, 14.25 mm) (p<0.05). There were higher incidences of anomalous branches such as ostial, accessory branches, or common ostia in the Afib group versus the non-Afib group (p<0.05). In Afib group, variable parameters of LA and PVs were obtained and estimated by MDCT, and there was statistically significant difference in the parameters of LA and PVs between Afib and non-Afib groups

  19. MDCT Evaluation of Left Atrium and Pulmonary Vein in the Patients with Atrial Fibrillation: Comparison with the Non-Atrial Fibrillation Group

    International Nuclear Information System (INIS)

    Kim, Won Jung; Choi, Eun Jeong; Ham, Soo Yeon; Oh, Yu Whan; Kim, Young Hoon; Yong, Hwan Seok; Yang, Kyung Sook

    2011-01-01

    The anatomy of the left atrium (LA) and the pulmonary veins (PVs) is important in planning and performing successful electrophysiologic ablation (EPA) for atrial fibrillation (Afib) patients. The authors estimated the findings of LA and PVs of Afib patients by MDCT, and compared these with the findings of LA and PVs of the non- Afib group using coronary CT angiography (CCTA). From September, 2009 to February, 2010, 91 Afib patients underwent PVCT (male: female = 72:19, mean age = 55.0-years-old) before EPA. At same time, 90 patients underwent CCTA (male: female = 73:17, mean age = 59.1- years-old). Two radiologists reviewed and analyzed all axial and 3D images of LA and PVs retrospectively with consensus. The average LA volumes of the Afib group(100.49 mm3) was larger than that of the non-Afib group (78.38 mm3) (p<0.05). The average lengths of the LA right wall in the Afib group (40.25 mm) was longer than that of the non-Afib group (37.3 mm) (p<0.05). The average distances between the PV ostium and first segmental bifurcation of the Lt superior PV (LSPV) and the RSPV were shorter in the Afib group (LSPV, 19.38 mm: RSPV, 11.49 mm) than in the non-Afib group (LSPV, 23.23 mm: RSPV, 14.25 mm) (p<0.05). There were higher incidences of anomalous branches such as ostial, accessory branches, or common ostia in the Afib group versus the non-Afib group (p<0.05). In Afib group, variable parameters of LA and PVs were obtained and estimated by MDCT, and there was statistically significant difference in the parameters of LA and PVs between Afib and non-Afib groups

  20. Cost-Effectiveness of Percutaneous Closure of the Left Atrial Appendage in Atrial Fibrillation Based on Results from PROTECT AF vs. PREVAIL

    Science.gov (United States)

    Freeman, James V.; Hutton, David W.; Barnes, Geoffrey D.; Zhu, Ruo P.; Owens, Douglas K.; Garber, Alan M.; Go, Alan S.; Hlatky, Mark A.; Heidenreich, Paul A.; Wang, Paul J.; Al-Ahmad, Amin; Turakhia, Mintu P.

    2016-01-01

    Background Randomized trials of left atrial appendage (LAA) closure with the Watchman device have shown varying results, and its cost-effectiveness compared to anticoagulation has not been evaluated using all available contemporary trial data. Methods and Results We used a Markov decision model to estimate lifetime quality-adjusted survival, costs, and cost-effectiveness of LAA closure with Watchman, compared directly with warfarin and indirectly with dabigatran, using data from the long-term (mean 3.8 year) follow-up of PROTECT AF and PREVAIL randomized trials. Using data from PROTECT AF, the incremental cost-effectiveness ratios (ICER) compared to warfarin and dabigatran were $20,486 and $23,422 per quality adjusted life year (QALY), respectively. Using data from PREVAIL, LAA closure was dominated by warfarin and dabigatran, meaning that it was less effective (8.44, 8.54, and 8.59 QALYs, respectively) and more costly. At a willingness-to-pay-threshold of $50,000 per QALY, LAA closure was cost-effective 90% and 9% of the time under PROTECT AF and PREVAIL assumptions, respectively. These results were sensitive to the rates of ischemic stroke and intracranial hemorrhage for LAA closure and medical anticoagulation. Conclusions Using data from the PROTECT AF trial, LAA closure with the Watchman device was cost-effective; using PREVAIL trial data, Watchman was more costly and less effective than warfarin and dabigatran. PROTECT AF enrolled more patients and has substantially longer follow-up time, allowing greater statistical certainty with the cost-effectiveness results. However, longer term trial results and post-marketing surveillance of major adverse events will be vital to determining the value of the Watchman in clinical practice. PMID:27307517

  1. Effect of the Size of the Left Atrium on Sustained Sinus Rhythm in Patients Undergoing Mitral Valve Surgery and Concomitant Bipolar Radiofrequency Ablation for Atrial Fibrillation.

    Science.gov (United States)

    Avdagić, Harun; Sijerčić Avdagić, Selma; Pirić Avdagić, Melika; Antonič, Miha

    2017-12-01

    Atrial fibrillation is associated with systemic embolization and complications due to anticoagulant therapy. Radiofrequency ablation has been established as an effective and safe method for the treatment of atrial fibrillation. The aim of this study was to evaluate the effect of the size of the left atrium on the outcome of surgical radiofrequency ablation. Forty patients scheduled for elective mitral valve surgery and radiofrequency ablation were enrolled in the study. Group 1 consisted of patients with a left atrium diameter ≤5 cm and group 2 of patients with left atrium diameter >5 cm. The primary endpoint of the study was stable sinus rhythm 6 months postoperatively. At 6 months postoperatively, sinus rhythm was present in significantly more group 1 patients as compared with group 2 patients, i.e. 15 (75%) vs. 8 (40%), p=0.025. Multivariate analysis proved the size of the left atrium to be an independent predictor of the radiofrequency ablation outcome. Accordingly, the size of the left atrium was demonstrated to be an important predictor of the outcome of radiofrequency ablation for atrial fibrillation. A lower cut-off value of surgical reduction of the atria than previously reported should be considered in order to improve the radiofrequency ablation outcome.

  2. Mechanical dyssynchrony of the left atrium during sinus rhythm is associated with history of stroke in patients with atrial fibrillation.

    Science.gov (United States)

    Ciuffo, Luisa; Inoue, Yuko Y; Tao, Susumu; Gucuk Ipek, Esra; Balouch, Muhammad; Lima, Joao A C; Nazarian, Saman; Spragg, David D; Marine, Joseph E; Berger, Ronald D; Calkins, Hugh; Ashikaga, Hiroshi

    2018-04-01

    We sought to evaluate the relationship between left atrial (LA) mechanical dyssynchrony and history of stroke or transient ischaemic attack (TIA) in patients with atrial fibrillation (AF). We hypothesized that mechanical dyssynchrony of the LA is associated with history of stroke/TIA independent of LA function and Cardiac failure, Hypertension, Age, Diabetes, Stroke/transient ischaemic attack (TIA), VAscular disease, and Sex category (CHA2DS2-VASc) score in patients with AF. We conducted a cross-sectional study of 246 patients with a history of AF (59 ± 10 years, 29% female, 26% non-paroxysmal AF) referred for catheter ablation to treat drug-refractory AF who underwent preablation cardiac magnetic resonance (CMR) in sinus rhythm. Using tissue-tracking CMR, we measured the LA longitudinal strain and strain rate in each of 12 equal-length segments in two- and four-chamber views. We defined indices of LA mechanical dyssynchrony, including the standard deviation of the time to the peak longitudinal strain (SD-TPS). Patients with a prior history of stroke or TIA (n = 23) had significantly higher SD-TPS than those without (n = 223) (39.9 vs. 23.4 ms, P stroke/TIA after adjusting for the CHA2DS2-VASc score, LA minimum index volume, and the peak LA longitudinal strain (P stroke/TIA more accurately than CHA2DS2-VASc score alone (c-statistics: 0.82 vs. 0.75, P stroke/TIA in patients with AF.

  3. Assessment of left ventricular function in patients with atrial fibrillation by left ventricular filling and function curves determined by ECG gated blood pool scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Suetsugu

    1986-06-01

    Accurate cardiac function in patients with atrial fibrillation (Af) is difficult to assess, since a wide fluctuation of cardiac cycle makes the ventricular hemodynamics variable. Although ECG gated blood pool scintigraphy (EGBPS) is useful to evaluate left ventricular (LV) function, a conventional EGBPS might have a problem in applying to Af. Therefore, a new processing algorithm was devised to make multiple gated images discriminated by preceding R-R intervals (PRR), and LV filling and function curves were obtained in 62 patients with Af to evaluate LV function. LV filling curve, obtained by plotting end-diastolic volume (EDV) againt PRR, demonstrated that the blood filling was impaired in mitral stenosis and constrictive pericarditis, but recovered after mitral commissurotomy. LV function curve, by plotting stroke volume (SV) againt EDV, was quantitatively analysed by the indices such as Slope and Position. Both indices reduced significantly in heart failure. When compared among underlying diseases individually, the indices decreased in the following order; lone Af, hyperthyroidism, senile Af, hypertension, mitral valve disease, ischemic heart disease, dilated cardiomyopathy and aortic regurgitation. After the treatment with digitalis and/or diuretics, left and upward shift of function curve was observed. The rise in heart rate by atropine infusion made Slope and Position unchanged, and which implied that function curve was little influenced by heart rate per se. The rise in systolic blood pressure by angiotensin-II infusion caused shifts in function curve to rightward and downward. Downward shift, mostly seen in patients with gentler slope in control state, may imply afterload mismatch due to a decrease in preload reserve. (J.P.N.).

  4. Assessment of ventriculo-vascular properties in repaired coarctation using cardiac magnetic resonance-derived aortic, left atrial and left ventricular strain

    Energy Technology Data Exchange (ETDEWEB)

    Shang, Quanliang [University of Nebraska College of Medicine and Children' s Hospital and Medical Center, Division of Pediatric Cardiology, Omaha, NE (United States); Central South University, Department of Radiology, Second Xiangya Hospital, Changsha, Hunan Province (China); Sarikouch, Samir; Beerbaum, Philipp [Hannover Medical School, Hannover (Germany); Patel, Shivani; Danford, David A.; Kutty, Shelby [University of Nebraska College of Medicine and Children' s Hospital and Medical Center, Division of Pediatric Cardiology, Omaha, NE (United States); Schuster, Andreas [Department of Cardiology and Pneumonology, Georg-August-University and German Center for Cardiovascular Research (DZHK, Partner Site), Goettingen (Germany); Steinmetz, Michael [Department of Pediatric Cardiology, Georg-August-University and German Center for Cardiovascular Research (DZHK, Partner Site), Goettingen (Germany); Ou, Phalla [University Paris Diderot, Department of Radiology, Hospital Bichat, APHP, Paris (France)

    2017-01-15

    In patients with repaired coarctation of aorta (CoA), we assessed ventriculo-vascular characteristics using CMR-derived aortic area strain (AAS), left atrial (LA) and left ventricular (LV) longitudinal and circumferential strain (LS, CS). Seventy-five subjects including 50 with repaired CoA divided into hypertensive (n = 25), normotensive (n = 25) and 25 controls were studied. AAS was measured at 3 levels: ascending aorta, proximal descending and descending aorta. LA and LV LS were measured using CMR-feature tracking. LA and LV end-diastolic volumes, ejection fraction (EF) and mass were measured. Mean patient age was 19.7 ± 6.7 and controls 23 ± 15 (years). All strains (LA, LV, ascending and descending aortic) were lower in CoA subgroups compared to controls except the AAS at diaphragm, which was not different. Comparisons between hypertensive and normotensive CoA showed no differences in LV mass, LV volumetric indices, and LA and LV strain indices; however, ascending AAS was lower in hypertensive subgroup (p = 0.02). Ascending AAS was correlated with LV mass (r = -0.4, p = 0.005), LVEF (r = -0.4, p = 0.004), systolic blood pressure (r = -0.5, p = 0.0001) and LVLS (r = 0.5, p = 0.001). Ascending AAS correlated with LV mass, EF and LVLS. In hypertensive CoA, ascending AAS was reduced compared to normotensive CoA and controls, indicating vascular remodelling differences influenced by ongoing hypertension. (orig.)

  5. Left atrial volume index as a predictor for persistent left ventricular dysfunction after aortic valve surgery in patients with chronic aortic regurgitation: the role of early postoperative echocardiography.

    Science.gov (United States)

    Cho, In-Jeong; Chang, Hyuk-Jae; Hong, Geu-Ru; Heo, Ran; Sung, Ji Min; Lee, Sang-Eun; Chang, Byung-Chul; Shim, Chi Young; Ha, Jong-Won; Chung, Namsik

    2015-06-01

    This study aimed to explore whether echocardiographic measurements during the early postoperative period can predict persistent left ventricular systolic dysfunction (LVSD) after aortic valve surgery in patients with chronic aortic regurgitation (AR). We prospectively recruited 54 patients (59 ± 12 years) with isolated chronic severe AR who subsequently underwent aortic valve surgery. Standard transthoracic echocardiography was performed before the operation, during the early postoperative period (≤2 weeks), and then 1 year after the surgery. Twelve patients with preoperative LVSD demonstrated LVSD at early after the surgery. Of the 42 patients without LVSD at preoperative echocardiography, 15 patients (36%) developed early postoperative LVSD after surgical correction. All 27 patients without LVSD at early postoperative echocardiography maintained LV function at 1 year after surgery. In the other 27 patients with postoperative LVSD, 17 patients recovered from LVSD and 10 patients did not at 1 year after surgery. Multiple logistic analysis demonstrated that postoperative left atrial volume index (LAVI) was the only independent predictor for persistent LVSD at 1 year after surgery in patients with postoperative LVSD (OR 1.180, 95% CI, 1.003-1.390, P = 0.046). The optimal LAVI cutoff value (>34.9 mL/m(2) ) had a sensitivity of 80% and a specificity of 88% for the prediction of persistent LVSD. Prevalence of early postoperative LVSD was relatively high, even in the patients without LVSD at preoperative echocardiography. Postoperative LAVI could be useful to predict persistent LVSD after aortic valve surgery in patients with early postoperative LVSD. © 2014, Wiley Periodicals, Inc.

  6. Anatomical analysis of incidental left atrial diverticula in patients with suspected coronary artery disease using 64-channel multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Shin, S.Y. [Department of Radiology, College of Medicine, Kyung Hee University, Seoul (Korea, Republic of); Kwon, S.H., E-mail: Kwon98@khu.ac.kr [Department of Radiology, College of Medicine, Kyung Hee University, Seoul (Korea, Republic of); Oh, J.H. [Department of Radiology, College of Medicine, Kyung Hee University, Seoul (Korea, Republic of)

    2011-10-15

    Aim: To describe and evaluate anatomical characterizations of incidental left atrial (LA) diverticula in patients with suspected coronary artery disease using 64-channel multidetector computed tomography (MDCT). Materials and methods: From October 2008 to June 2009, 2059 patients with suspected coronary artery disease underwent electrocardiogram-gated 64-channel MDCT. Five hundred and thirty-two LA diverticula were identified in 377 patients (18.3%, male to female ratio: 216:161, mean age 59 {+-} 10.89 years, range from 20 to 91 years). Two radiologists retrospectively analysed the number (single or multiple), size (diameter and length), shape (cystiform or tubiform), surface (smooth or irregular), and location (right or mid or left/upper or lower/lateral or posterior). If the length/diameter was <1.5, the diverticular shape was considered to be cystiform. Results: Among 532 LA diverticula, single (270/532, 51.1%), cystiform (411/532, 77.3%), and smooth (332/532, 62.4%) diverticula were found. The right upper region (255/532, 47.9%) was the most common location, followed by the left lateral area (172/532, 32.3%). The average diameter was 4.7 {+-} 2 mm (range from 1-19 mm), and the average length was 4.7 {+-} 2.1 mm (range 1-13 mm). The average ratio of length to diameter was 1.15 (range 0.25-1.45). The average number of diverticula was 2 {+-} 1.06 (range 1-5). Conclusion: Incidental LA diverticulum is not an uncommon finding in patients with suspected coronary artery disease. MDCT can provide anatomical details of LA diverticula. However, further studies are needed to determine their clinical significance.

  7. Prognostic value of left atrial function in systemic light-chain amyloidosis: a cardiac magnetic resonance study.

    Science.gov (United States)

    Mohty, Dania; Boulogne, Cyrille; Magne, Julien; Varroud-Vial, Nicolas; Martin, Sylvain; Ettaif, Hind; Fadel, Bahaa M; Bridoux, Frank; Aboyans, Victor; Damy, Thibaud; Jaccard, Arnaud

    2016-09-01

    Cardiac involvement in systemic light-chain amyloidosis (AL) imparts an adverse impact on outcome. The left atrium (LA), by virtue of its anatomical location and muscular wall, is commonly affected by the amyloid process. Although LA infiltration by amyloid fibrils leads to a reduction in its pump function, the infiltration of the left ventricular (LV) myocardium results in diastolic dysfunction with subsequent increase in filling pressures and LA enlargement. Even though left atrial volume (LAV) is an independent prognostic marker in many cardiomyopathies, its value in amyloid heart disease remains to be determined. In addition, few data are available as to the prognostic value of LA function in systemic AL. Using cardiac magnetic resonance (CMR), the current study aims to assess the prognostic significance of the maximal LAV and total LA emptying fraction (LAEF) in patients with AL. Fifty-four consecutive patients (age 66 ± 10 years, 59% males) with confirmed systemic AL and mean LV ejection fraction of 60 ± 12% underwent CMR. As compared with patients with no or minimal cardiac involvement (Mayo Clinic [MC] stage I), those at moderate and high risk (MC stages II and III) had significantly larger indexed maximal LAV (36 ± 15 vs. 46 ± 13 vs. 52 ± 19 mL/m(2), P = 0.03) and indexed minimal LAV (20 ± 6 vs. 34 ± 11 vs. 44 ± 17 mL/m(2), P 16% (37 ± 11 vs. 94 ± 4%, P = 0.001). In multivariate analysis, lower LAEF remained independently associated with a higher risk of 2-year mortality (HR = 1.08 per 1% decrease, 95% CI: 1.02-1.15, P = 0.003). In patients with systemic AL, LAEF as assessed by CMR is associated with NYHA functional class, MC stage, myocardial LGE and 2-year mortality. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  8. “Anomalous right pulmonary artery left atrial fistula”: Growth in vain

    Directory of Open Access Journals (Sweden)

    Vishal Kumar Jain

    2015-12-01

    Full Text Available We report a case of direct communication between the right pulmonary artery and the left atrium; a rare cause of central cyanosis in 10 year old boy, emphasizing the role of multislice computed tomography scanner in delineating the complex vascular abnormality over more invasive conventional angiography.

  9. 3D patient-specific models for left atrium characterization to support ablation in atrial fibrillation patients.

    Science.gov (United States)

    Valinoti, Maddalena; Fabbri, Claudio; Turco, Dario; Mantovan, Roberto; Pasini, Antonio; Corsi, Cristiana

    2018-01-01

    Radiofrequency ablation (RFA) is an important and promising therapy for atrial fibrillation (AF) patients. Optimization of patient selection and the availability of an accurate anatomical guide could improve RFA success rate. In this study we propose a unified, fully automated approach to build a 3D patient-specific left atrium (LA) model including pulmonary veins (PVs) in order to provide an accurate anatomical guide during RFA and without PVs in order to characterize LA volumetry and support patient selection for AF ablation. Magnetic resonance data from twenty-six patients referred for AF RFA were processed applying an edge-based level set approach guided by a phase-based edge detector to obtain the 3D LA model with PVs. An automated technique based on the shape diameter function was designed and applied to remove PVs and compute LA volume. 3D LA models were qualitatively compared with 3D LA surfaces acquired during the ablation procedure. An expert radiologist manually traced the LA on MR images twice. LA surfaces from the automatic approach and manual tracing were compared by mean surface-to-surface distance. In addition, LA volumes were compared with volumes from manual segmentation by linear and Bland-Altman analyses. Qualitative comparison of 3D LA models showed several inaccuracies, in particular PVs reconstruction was not accurate and left atrial appendage was missing in the model obtained during RFA procedure. LA surfaces were very similar (mean surface-to-surface distance: 2.3±0.7mm). LA volumes were in excellent agreement (y=1.03x-1.4, r=0.99, bias=-1.37ml (-1.43%) SD=2.16ml (2.3%), mean percentage difference=1.3%±2.1%). Results showed the proposed 3D patient-specific LA model with PVs is able to better describe LA anatomy compared to models derived from the navigation system, thus potentially improving electrograms and voltage information location and reducing fluoroscopic time during RFA. Quantitative assessment of LA volume derived from our 3D LA

  10. Echocardiographic predictors of early in-hospital heart failure during first ST-elevation acute myocardial infarction: does myocardial performance index and left atrial volume improve diagnosis over conventional parameters of left ventricular function?

    Directory of Open Access Journals (Sweden)

    Machado Cristiano V

    2011-06-01

    Full Text Available Abstract Background Left ventricular ejection fraction (LVEF has been considered a major determinant of early outcome in acute myocardial infarction (AMI. Myocardial performance index (MPI has been associated to early evolution in AMI in a heterogeneous population, including non ST-elevation or previous AMI. Left atrial volume has been related with late evolution after AMI. We evaluated the independent role of clinical and echocardiographic variables including LVEF, MPI and left atrial volume in predicting early in-hospital congestive heart failure (CHF specifically in patients with a first isolated ST-elevation AMI. Methods Echocardiography was performed within 30 hours of chest pain in 95 patients with a first ST-elevation AMI followed during the first week of hospitalization. Several clinical and echocardiographic variables were analyzed. CHF was defined as Killip class ≥ II. Multivariate regression analysis was used to select independent predictor of in-hospital CHF. Results Early in-hospital CHF occurred in 29 (31% of patients. LVEF ≤ 0.45 was the single independent and highly significant predictor of early CHF among other clinical and echocardiographic variables (odds ratio 17.0; [95% CI 4.1 - 70.8]; p Conclusion For patients with first, isolated ST-elevation AMI, LVEF assessed by echocardiography still constitutes a strong and accurate independent predictor of early in-hospital CHF, superior to isolated MPI and left atrial volume in this particular subset of patients.

  11. Isquemia cerebral como manifestación inicial de un mixoma atrial izquierdo: Reporte de un caso Brain ischemia as initial sign of a left atrial myxoma: Report of one case

    Directory of Open Access Journals (Sweden)

    Luis F Osio

    2008-04-01

    Full Text Available Los tumores primarios del corazón son raros; 75% de éstos son benignos y cerca de la mitad de los benignos son mixomas que, en la mayoría de los casos, se encuentran en las cavidades izquierdas. Las manifestaciones clínicas de los mixomas dependen del sitio de localización del tumor. Sin embargo, se afirma que la isquemia cerebral es la manifestación clínica inicial en un tercio de los mixomas atriales. Se presenta el caso de un paciente de género masculino, de 65 años de edad, en quien la primera manifestación clínica de mixoma atrial fue un evento cerebral vascular isquémico.Primary heart tumors are rare; 75% of them are benign and almost half of the benign ones are mixomas that in most cases are located in the left cavities. Clinical manifestations of myxomas depend on its localization site. Nevertheless, it is accepted that brain ischemia is the initial clinical manifestation in a third of atrial myxomas. The case of a 65 years old male patient in whom the first clinical manifestation of an atrial myxoma was an ischemic cerebrovascular event, is presented.

  12. Evaluation of left atrial linear ablation using contiguous and optimized radiofrequency lesions: the ALINE study.

    Science.gov (United States)

    Wolf, Michael; El Haddad, Milad; Fedida, Joël; Taghji, Philippe; Van Beeumen, Katarina; Strisciuglio, Teresa; De Pooter, Jan; Lepièce, Caroline; Vandekerckhove, Yves; Tavernier, René; Duytschaever, Mattias; Knecht, Sébastien

    2018-01-08

    Achieving block across linear lesions is challenging. We prospectively evaluated radiofrequency (RF) linear ablation at the roof and mitral isthmus (MI) using point-by-point contiguous and optimized RF lesions. Forty-one consecutive patients with symptomatic persistent AF underwent stepwise contact force (CF)-guided catheter ablation during ongoing AF. A single linear set of RF lesions was delivered at the roof and posterior MI according to the 'Atrial LINEar' (ALINE) criteria, i.e. point-by-point RF delivery (up to 35 W) respecting strict criteria of contiguity (inter-lesion distance ≤ 6 mm) and indirect lesion depth assessment (ablation index ≥550). We assessed the incidence of bidirectional block across both lines only after restoration of sinus rhythm. After a median RF time of 7 min [interquartile range (IQR) 5-9], first-pass block across roof lines was observed in 38 of 41 (93%) patients. Final bidirectional roof block was achieved in 40 of 41 (98%) patients. First-pass block was observed in 8 of 35 (23%) MI lines, after a median RF time of 8 min (IQR 7-12). Additional endo- and epicardial (54% of patients) RF applications resulted in final bidirectional MI block in 28 of 35 (80%) patients. During a median follow-up of 396 (IQR 310-442) days, 12 patients underwent repeat procedures, with conduction recovery in 4 of 12 and 5 of 10 previously blocked roof lines and MI lines, respectively. No complications occurred. Anatomical linear ablation using contiguous and optimized RF lesions results in a high rate of first-pass block at the roof but not at the MI. Due to its complex 3D architecture, the MI frequently requires additional endo- and epicardial RF lesions to be blocked. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author(s) 2018. For permissions, please email: journals.permissions@oup.com.

  13. Assessment of normal left atrial appendage anatomy and function over gender and ages by dynamic cardiac CT

    International Nuclear Information System (INIS)

    Boucebci, Samy; Velasco, Stephane; Duboe, Pier-Olivier; Tasu, Jean-Pierre; Pambrun, Thomas; Ingrand, Pierre

    2016-01-01

    The aim of this study was to evaluate variations in anatomy and function according to age and gender using cardiac computed tomography (CT) in a large prospective cohort of healthy patients. The left atrial appendage (LAA) is considered the most frequent site of intracardiac thrombus formation. However, variations in normal in vivo anatomy and function according to age and gender remain largely unknown. Three-dimensional (3D) cardiac reconstructions of the LAA were performed from CT scans of 193 consecutive patients. Parameters measured included LAA number of lobes, anatomical position of the LAA tip, angulation measured between the proximal and distal portions, minimum (iVol min ) and maximum (iVol max ) volumes indexed to body surface area (BSA), and ejection fraction (LAAEF). Relationship with age was assessed for each parameter. We found that men had longer and wider LAAs. The iVol min and iVol max increased by 0.23 and 0.19 ml per decade, respectively, while LAAEF decreased by 2 % per decade in both sexes. Although LAA volumes increase, LAAEF decreases with age in both sexes. (orig.)

  14. Assessment of normal left atrial appendage anatomy and function over gender and ages by dynamic cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Boucebci, Samy; Velasco, Stephane; Duboe, Pier-Olivier; Tasu, Jean-Pierre [University of Poitiers, University Hospital, Department of Radiology, Poitiers (France); Pambrun, Thomas [University of Poitiers, University Hospital, Department of Cardiology, Poitiers (France); Ingrand, Pierre [University of Poitiers, University Institute of Public Health, Poitiers (France)

    2016-05-15

    The aim of this study was to evaluate variations in anatomy and function according to age and gender using cardiac computed tomography (CT) in a large prospective cohort of healthy patients. The left atrial appendage (LAA) is considered the most frequent site of intracardiac thrombus formation. However, variations in normal in vivo anatomy and function according to age and gender remain largely unknown. Three-dimensional (3D) cardiac reconstructions of the LAA were performed from CT scans of 193 consecutive patients. Parameters measured included LAA number of lobes, anatomical position of the LAA tip, angulation measured between the proximal and distal portions, minimum (iVol{sub min}) and maximum (iVol{sub max}) volumes indexed to body surface area (BSA), and ejection fraction (LAAEF). Relationship with age was assessed for each parameter. We found that men had longer and wider LAAs. The iVol{sub min} and iVol{sub max} increased by 0.23 and 0.19 ml per decade, respectively, while LAAEF decreased by 2 % per decade in both sexes. Although LAA volumes increase, LAAEF decreases with age in both sexes. (orig.)

  15. Thallium pulmonary scintigraphy. Relationship to pulmonary fluid volumes during left atrial hypertension and the acute release of pressure

    International Nuclear Information System (INIS)

    Slutsky, R.A.

    1984-01-01

    To evaluate the relationship between thallium-201 lung activity and pulmonary fluid volumes, we compared thallium pulmonary scintigrams with measures of intravascular (PBV), extravascular (EVLW) and total lung water (TLW) during gradual left atrial (LA) hypertension and then serially after the acute release of pressure. The study group was composed of nine mongrel dogs who were each studied at seven levels of elevated LA pressure, and then every 15 minutes for 2 hours after the acute release of pressure. During LA pressure (congestion phase) elevation, lung counts (normalized for myocardial activity), correlated best with TLW (r . .91), rather than PBV (r . .84) or EVLW (r . .81). After the release of pressure (recovery phase), lung counts correlated well with EVLW (r . .92) and TLW (r . .82), but not with PBV (r . .28). Postmortem lung counts from 197 separate lung sections correlated well with the corresponding wet weight/dry weight ratio from that section (r . .81). Thus, we conclude that changes in pulmonary thallium emissions during cardiogenic pulmonary edema relate to corresponding changes in pulmonary fluid volumes. During congestion, the confounding effects of nonlinear increases in EVLW and PBV make thallium emissions more a marker of TLW than either the intravascular or extravascular pulmonary fluid compartment. After pressure release, PBV immediately returns to normal, at which time EVLW and pulmonary emissions correlate closely. These latter data, more applicable to postexercise stress thallium data, lend support to the hypothesis that elevated pulmonary emissions during postexercise thallium scintigrams reflect elevations in EVLW that develop during exercise

  16. Contrast-enhanced CMR in patients after percutaneous closure of the left atrial appendage: A pilot study

    Directory of Open Access Journals (Sweden)

    Petersen Steffen E

    2011-07-01

    Full Text Available Abstract Background To evaluate the feasibility and value of first-pass contrast-enhanced dynamic and post-contrast 3D CMR in patients after transcatheter occlusion of left atrial appendage (LAA to identify incorrect placement and persistent leaks. Methods 7 patients with different occluder systems (n = 4 PLAATO; n = 2 Watchman; n = 1 ACP underwent 2 contrast-enhanced (Gd-DOTA CMR sequences (2D TrueFISP first-pass perfusion and 3D-TurboFLASH to assess localization, artifact size and potential leaks of the devices. Perfusion CMR was analyzed visually and semi-quantitatively to identify potential leaks. Results All occluders were positioned within the LAA. The ACP occluder presented the most extensive artifact size. Visual assessment revealed a residual perfusion of the LAA apex in 4 cases using first-pass perfusion and 3D-TurboFLASH indicating a suboptimal LAA occlusion. By assessing signal-to-time-curves the cases with a visually detected leak showed a 9-fold higher signal-peak in the LAA apex (567 ± 120% increase from baseline signal than those without a leak (61 ± 22%; p Conclusion This CMR pilot study provides valuable non-invasive information in patients after transcatheter occlusion of the LAA to identify correct placement and potential leaks. We recommend incorporating CMR in future clinical studies to evaluate new device types.

  17. Comparative effects of amlodipine and benazepril on left atrial pressure in dogs with experimentally-induced mitral valve regurgitation.

    Science.gov (United States)

    Suzuki, Shuji; Fukushima, Ryuji; Ishikawa, Taisuke; Yamamoto, Yuta; Hamabe, Lina; Kim, Soomin; Yoshiyuki, Rieko; Machida, Noboru; Tanaka, Ryou

    2012-09-18

    One of the purposes of treatment for dogs with mitral regurgitation (MR) is lowering left atrial pressure (LAP). There has been few study of the amlodipine in dogs with MR and amlodipine's effect on LAP has not been fully evaluated in a quantitative manner because of difficulties in directly measuring LAP. The objective of our study was to compare the short-term effects of amlodipine (0.2 mg/kg PO q12h) vs benazepril (0.5 mg/kg PO q12h), on LAP and echocardiographic parameters in five beagle dogs with experimentally-induced MR. LAP of eight dogs that has own control were measured using radiotelemetry system at baseline and again on days 1, 2, 3, 4, 5, 6, 7 of the drug administration. Mean LAP decreased significantly after amlodipine (11.20 ± 4.19 mmHg vs 14.61 ± 3.81 mmHg at baseline, p benazepril treatment (13.19 ± 3.47 mmHg, p > .05). LAP was lower after 7 days of amlodipine treatment than after 7 days of benazepril treatment. Significant reduction was seen for the first time 4 days after the administration amlodipine. The rate of the maximal area of the regurgitant jet signals to the left atrium area (ARJ/LAA) of the amlodipine treatment was significantly lower (p benazepril treatment. Although this study did not focus on adverse effects, amlodipine may be an effective drug for helping the patients with acute onset of severe MR, such as rupture of chordae tendinae or end stage patients were the LAP is likely to be elevated. Additional studies in clinical patients with degenerative mitral valve disease and acute chordal rupture are warranted because the blood-pressure lowering effects of amlodipine can decrease renal perfusion and this can further activate the RAAS.

  18. Left atrial dysfunction in type 2 diabetes mellitus: insights from cardiac MRI

    Energy Technology Data Exchange (ETDEWEB)

    Graca, Bruno; Donato, Paulo; Caseiro-Alves, Filipe [University of Coimbra, Faculty of Medicine, Coimbra (Portugal); Coimbra' s Hospital Centre and University, Medical Imaging Department, Coimbra (Portugal); Joao Ferreira, Maria [University of Coimbra, Faculty of Medicine, Coimbra (Portugal); Coimbra' s Hospital Centre and University, Cardiology Department, Coimbra (Portugal); Gomes, Leonor [University of Coimbra, Faculty of Medicine, Coimbra (Portugal); Coimbra' s Hospital Centre and University, Endocrinology Department, Coimbra (Portugal); Castelo-Branco, Miguel [University of Coimbra, Faculty of Medicine, Coimbra (Portugal)

    2014-11-15

    The left atrium (LA) modulates left ventricular filling through reservoir, conduit and booster pump functions. Only limited data exist on LA involvement in type 2 diabetes mellitus (DM2). This study sought to assess LA function in asymptomatic DM2 with cardiac MRI. We hypothesized that cardiac MRI can detect LA dysfunction in asymptomatic DM2. Forty-five patients with asymptomatic DM2 and 24 normoglycaemic controls were studied. MRI cine imaging was performed to measure LA maximal and minimal volumes. A flow-sensitive phase-contrast gradient-echo sequence was used for flow measurements perpendicular to the orifice of the mitral valve, to quantify active LA stroke volume. LA total, passive and active emptying volumes and fractions were calculated. LA reservoir function, namely LA total ejection fraction, was significantly greater in controls compared to patients with DM2 (62.2 ± 5.2 vs 57.0 ± 7.6 %, P = 0.004). LA passive ejection fraction was also greater in the controls (26.2 ± 9.5 vs 16.1 ± 11.0 %, P < 0.001). Regarding parameters of LA booster pump function, LA active ejection fraction was not significantly different between groups. DM2 was demonstrated to be an independent determinant of LA function. Cardiac MRI enables the detection of LA dysfunction in asymptomatic DM2, characterized by a reduction in LA reservoir and conduit functions. (orig.)

  19. Left septal atrial tachycardia after open-heart surgery: relevance to surgical approach, anatomical and electrophysiological characteristics associated with catheter ablation, and procedural outcomes.

    Science.gov (United States)

    Adachi, Toru; Yoshida, Kentaro; Takeyasu, Noriyuki; Masuda, Keita; Sekiguchi, Yukio; Sato, Akira; Tada, Hiroshi; Nogami, Akihiko; Aonuma, Kazutaka

    2015-02-01

    Septal atrial tachycardia (AT) can occur in patients without structural heart disease and in patients with previous catheter ablation of atrial fibrillation. We aimed to assess septal AT that occurs after open-heart surgery. This study comprised 20 consecutive patients undergoing catheter ablation of macroreentrant AT after open-heart surgery. Relevance to surgical approach, mechanisms, anatomic and electrophysiological characteristics, and outcomes were assessed. Septal AT was identified in 7 patients who had all undergone mitral valve surgery. All septal ATs were localized in the left atrial septum, whereas 10 of 13 nonseptal ATs originated from the right atrium. Patients with left septal AT had a thicker fossa ovalis (median, 4.0; 25th-75th percentile, 3.6-4.2 versus 2.3; 1.6-2.6 mm; P=0.006) and broader area of low voltage (open-heart surgery was characterized by a thicker septum, more scar burden in the septum, and repeated prolongations of the tachycardia cycle length during ablation. Such an arrhythmogenic substrate may interfere with transmural lesion formation by ablation and may account for higher likelihood of recurrence of left septal AT. © 2014 American Heart Association, Inc.

  20. Diagnostic accuracy of electrocardiographic P wave related parameters in the assessment of left atrial size in dogs with degenerative mitral valve disease.

    Science.gov (United States)

    Soto-Bustos, Ángel; Caro-Vadillo, Alicia; Martínez-DE-Merlo, Elena; Alonso-Alegre, Elisa González

    2017-10-07

    The purpose of this research was to compare the accuracy of newly described P wave-related parameters (P wave area, Macruz index and mean electrical axis) with classical P wave-related parameters (voltage and duration of P wave) for the assessment of left atrial (LA) size in dogs with degenerative mitral valve disease. One hundred forty-six dogs (37 healthy control dogs and 109 dogs with degenerative mitral valve disease) were prospectively studied. Two-dimensional echocardiography examinations and a 6-lead ECG were performed prospectively in all dogs. Echocardiography parameters, including determination of the ratios LA diameter/aortic root diameter and LA area/aortic root area, were compared to P wave-related parameters: P wave area, Macruz index, mean electrical axis voltage and duration of P wave. The results showed that P wave-related parameters (classical and newly described) had low sensitivity (range=52.3 to 77%; median=60%) and low to moderate specificity (range=47.2 to 82.5%; median 56.3%) for the prediction of left atrial enlargement. The areas under the curve of P wave-related parameters were moderate to low due to poor sensitivity. In conclusion, newly P wave-related parameters do not increase the diagnostic capacity of ECG as a predictor of left atrial enlargement in dogs with degenerative mitral valve disease.

  1. Adding left atrial appendage closure to open heart surgery provides protection from ischemic brain injury six years after surgery independently of atrial fibrillation history

    DEFF Research Database (Denmark)

    Park-Hansen, Jesper; Holme, Susanne J V; Irmukhamedov, Akhmadjon

    2018-01-01

    BACKGROUND: Open heart surgery is associated with high occurrence of atrial fibrillation (AF), subsequently increasing the risk of post-operative ischemic stroke. Concomitant with open heart surgery, a cardiac ablation procedure is commonly performed in patients with known AF, often followed by l...

  2. Characterization and distribution of receptors for the atrial natriuretic peptides in mammalian brain

    International Nuclear Information System (INIS)

    Quirion, R.; Dalpe, M.; Dam, T.V.

    1986-01-01

    Both rat 125 I-labeled atrial natriuretic polypeptide [ 125 I-ANP or atrial natriuretic factor fragment ANF-(99-126)] and human 125 I-α-ANP or human ANF-(99-126)] bind with high specificity and affinity to an apparent single class of sites in guinea pig brain. Similar results have been reported in peripheral tissues, which indicate that central and peripheral ANP binding sites have fairly similar structural requirements. In vitro receptor autoradiography shows that in the guinea pig brain, 125 I-ANP binding sites are highly concentrated in the external plexiform layer of the olfactory bulb, subfornical organ, various thalamic nuclei, medial geniculate nucleus, and cerebellum. Lower densities are found in the central nucleus of the amygdala, dentate gyrus, hippocampus, and area postrema. Most remaining regions contain much lower densities of sites. In rat brain 125 I-ANP binding sites are differentially distributed, with high densities in the subfornical organ, area postrema, and linings of ventricles but low densities in the thalamus and cerebellum. In monkey brain, 125 I-ANP binding sites are concentrated in the cerebellum. The presence of high densities of 125 I-ANP binding sites in various brain regions strongly suggests the existence of a family of brain-heart peptides, in analogy to the well-known brain-gut peptides. Moreover, the extensive distribution of 125 I-ANP binding sites in mammalian brain suggests that the possible roles of ANP/ANF-like peptides in brain are not restricted to the central regulation of cardiovascular parameters

  3. Atrial natriuretic peptide receptor heterogeneity and effects on cyclic GMP accumulation

    International Nuclear Information System (INIS)

    Leitman, D.C.

    1988-01-01

    The effects of atrial natriuretic peptide (ANP), oxytocin (OT) and vasopressin (AVP) on guanylate cyclase activity and cyclic GMP accumulation were examined, since these hormones appear to be intimately associated with blood pressure and intravascular volume homeostasis. ANP was found to increase cyclic GMP accumulation in ten cell culture systems, which were derived from blood vessels, adrenal cortex, kidney, lung, testes and mammary gland. ANP receptors were characterized in intact cultured cells using 125 I-ANP 8-33 . Specific 125 I-ANP binding was saturable and of high affinity. Scratchard analysis of the binding data for all cell types exhibited a straight line, indicating that these cells possessed a single class of binding sites. Despite the presence of linear Scatchard plots, these studies demonstrated that cultured cells possess two functionally and physically distinct ANP-binding sites. Most of the ANP-binding sites in cultured cells have a molecular size of 66,000 daltons under reducing conditions. The identification of cultured cell types in which hormones (ANP and oxytocin) regulate guanylate cyclase activity and increase cyclic GMP synthesis will provide valuable systems to determine the mechanisms of hormone-receptor coupling to guanylate cyclase and the cellular processes regulated by cyclic GMP

  4. Decreases in left atrial compliance during early-stage exercise are related to exercise intolerance in asymptomatic significant mitral stenosis.

    Science.gov (United States)

    Jung, Mi-Hyang; Jung, Hae Ok; Lee, Jung-Won; Youn, Ho-Joong

    2017-11-01

    Doppler-driven net atrioventricular compliance (C n ), which represents left atrial (LA) compliance, is an important determinant of pulmonary hypertension in mitral stenosis (MS). We hypothesized that decreases in C n during early-stage exercise underlie exercise intolerance in patients with MS. Thirty-three asymptomatic patients with significant MS (valve area 1.24 ± 0.16 cm 2 ) underwent resting and bicycle exercise echocardiography. LA compliance and conventional parameters were assessed at each workload. The patients were classified into two groups based on whether they developed dyspnea during exercise: an exercise-intolerance group (n = 22) and an exercise-tolerance group (n = 11). Moreover, "50 W" was defined as an early exercise stage. Although the groups had similar resting characteristics, there were striking differences in their echocardiographic parameters from the early stages of exercise. The relative C n decrease at 50 W (expressed as a percentage of the resting C n ) was significantly greater in the exercise-intolerance group (70.3 ± 15.4% vs 49.7 ± 9.7%, P intolerance group (P = .0005). Furthermore, differences in the trends in this parameter were observed between the two groups (P intolerance (adjusted OR 1.105, 95% CI 1.030-1.184) after adjustment for other conventional parameters. Decreases in C n during early-stage exercise are an important mechanism underlying exercise intolerance in MS. © 2017, Wiley Periodicals, Inc.

  5. Optimal Analysis of Left Atrial Strain by Speckle Tracking Echocardiography: P-wave versus R-wave Trigger.

    Science.gov (United States)

    Hayashi, Shuji; Yamada, Hirotsugu; Bando, Mika; Saijo, Yoshihito; Nishio, Susumu; Hirata, Yukina; Klein, Allan L; Sata, Masataka

    2015-08-01

    Left atrial (LA) strain analysis using speckle tracking echocardiography is useful for assessing LA function. However, there is no established procedure for this method. Most investigators have determined the electrocardiographic R-wave peak as the starting point for LA strain analysis. To test our hypothesis that P-wave onset should be used as the starting point, we measured LA strain using 2 different starting points and compared the strain values with the corresponding LA volume indices obtained by three-dimensional (3D) echocardiography. We enrolled 78 subjects (61 ± 17 years, 25 males) with and without various cardiac diseases in this study and assessed global longitudinal LA strain by two-dimensional speckle tracking strain echocardiography using EchoPac software. We used either R-wave peak or P-wave onset as the starting point for determining LA strains during the reservoir (Rres, Pres), conduit (Rcon, Pcon), and booster pump (Rpump, Ppump) phases. We determined the maximum, minimum, and preatrial contraction LA volumes, and calculated the LA total, passive, and active emptying fractions using 3D echocardiography. The correlation between Pres and LA total emptying fraction was better than the correlation between Rres and LA total emptying fraction (r = 0.458 vs. 0.308, P = 0.026). Pcon and Ppump exhibited better correlation with the corresponding 3D echocardiographic parameters than Rcon (r = 0.560 vs. 0.479, P = 0.133) and Rpump (r = 0.577 vs. 0.345, P = 0.003), respectively. LA strain in any phase should be analyzed using P-wave onset as the starting point rather than R-wave peak. © 2014, Wiley Periodicals, Inc.

  6. Quantitative modeling of the accuracy in registering preoperative patient-specific anatomic models into left atrial cardiac ablation procedures

    Energy Technology Data Exchange (ETDEWEB)

    Rettmann, Maryam E., E-mail: rettmann.maryam@mayo.edu; Holmes, David R.; Camp, Jon J.; Cameron, Bruce M.; Robb, Richard A. [Biomedical Imaging Resource, Mayo Clinic College of Medicine, Rochester, Minnesota 55905 (United States); Kwartowitz, David M. [Department of Bioengineering, Clemson University, Clemson, South Carolina 29634 (United States); Gunawan, Mia [Department of Biochemistry and Molecular and Cellular Biology, Georgetown University, Washington D.C. 20057 (United States); Johnson, Susan B.; Packer, Douglas L. [Division of Cardiovascular Diseases, Mayo Clinic, Rochester, Minnesota 55905 (United States); Dalegrave, Charles [Clinical Cardiac Electrophysiology, Cardiology Division Hospital Sao Paulo, Federal University of Sao Paulo, 04024-002 Brazil (Brazil); Kolasa, Mark W. [David Grant Medical Center, Fairfield, California 94535 (United States)

    2014-02-15

    Purpose: In cardiac ablation therapy, accurate anatomic guidance is necessary to create effective tissue lesions for elimination of left atrial fibrillation. While fluoroscopy, ultrasound, and electroanatomic maps are important guidance tools, they lack information regarding detailed patient anatomy which can be obtained from high resolution imaging techniques. For this reason, there has been significant effort in incorporating detailed, patient-specific models generated from preoperative imaging datasets into the procedure. Both clinical and animal studies have investigated registration and targeting accuracy when using preoperative models; however, the effect of various error sources on registration accuracy has not been quantitatively evaluated. Methods: Data from phantom, canine, and patient studies are used to model and evaluate registration accuracy. In the phantom studies, data are collected using a magnetically tracked catheter on a static phantom model. Monte Carlo simulation studies were run to evaluate both baseline errors as well as the effect of different sources of error that would be present in a dynamicin vivo setting. Error is simulated by varying the variance parameters on the landmark fiducial, physical target, and surface point locations in the phantom simulation studies. In vivo validation studies were undertaken in six canines in which metal clips were placed in the left atrium to serve as ground truth points. A small clinical evaluation was completed in three patients. Landmark-based and combined landmark and surface-based registration algorithms were evaluated in all studies. In the phantom and canine studies, both target registration error and point-to-surface error are used to assess accuracy. In the patient studies, no ground truth is available and registration accuracy is quantified using point-to-surface error only. Results: The phantom simulation studies demonstrated that combined landmark and surface-based registration improved

  7. Comparative effects of amlodipine and benazepril on Left Atrial Pressure in Dogs with experimentally-induced Mitral Valve Regurgitation

    Directory of Open Access Journals (Sweden)

    Suzuki Shuji

    2012-09-01

    Full Text Available Abstract Background One of the purposes of treatment for dogs with mitral regurgitation (MR is lowering left atrial pressure (LAP. There has been few study of the amlodipine in dogs with MR and amlodipine’s effect on LAP has not been fully evaluated in a quantitative manner because of difficulties in directly measuring LAP. The objective of our study was to compare the short-term effects of amlodipine (0.2 mg/kg PO q12h vs benazepril (0.5 mg/kg PO q12h, on LAP and echocardiographic parameters in five beagle dogs with experimentally-induced MR. LAP of eight dogs that has own control were measured using radiotelemetry system at baseline and again on days 1, 2, 3, 4, 5, 6, 7 of the drug administration. Results Mean LAP decreased significantly after amlodipine (11.20 ± 4.19 mmHg vs 14.61 ± 3.81 mmHg at baseline, p  .05. LAP was lower after 7 days of amlodipine treatment than after 7 days of benazepril treatment. Significant reduction was seen for the first time 4 days after the administration amlodipine. The rate of the maximal area of the regurgitant jet signals to the left atrium area (ARJ/LAA of the amlodipine treatment was significantly lower (p  Conclusions LAP was significantly decreased after amlodipine treatment in dogs with surgically-induced MR but not after benazepril treatment. Although this study did not focus on adverse effects, amlodipine may be an effective drug for helping the patients with acute onset of severe MR, such as rupture of chordae tendinae or end stage patients were the LAP is likely to be elevated. Additional studies in clinical patients with degenerative mitral valve disease and acute chordal rupture are warranted because the blood-pressure lowering effects of amlodipine can decrease renal perfusion and this can further activate the RAAS.

  8. Three-dimensional speckle tracking echocardiography allows detailed evaluation of left atrial function in hypertrophic cardiomyopathy--insights from the MAGYAR-Path Study.

    Science.gov (United States)

    Domsik, Péter; Kalapos, Anita; Chadaide, Számi; Sepp, Róbert; Hausinger, Péter; Forster, Tamás; Nemes, Attila

    2014-11-01

    Hypertrophic cardiomyopathy (HCM) represents a generalized myopathic process affecting both ventricular and atrial myocardium. Reduced left atrial (LA) function was demonstrated in HCM by different methods. Three-dimensional (3D) speckle tracking echocardiography (STE) has just been introduced for the evaluation of LA. This study was designed to compare 3DSTE-derived LA volumetric and strain parameters in HCM with healthy controls. The study comprised 23 consecutive HCM patients (mean age: 48.5 ± 15.1 years, 14 men). Their results were compared to 23 age- and gender-matched healthy controls. Complete two-dimensional Doppler echocardiography and 3DSTE have been performed in all cases. Calculated LA maximum (66.4 ± 20.4 mL vs. 36.0 ± 6.1 mL, P echocardiography allows detailed evaluation of LA (dys) function in HCM by volumetric and strain measurements. © 2014, Wiley Periodicals, Inc.

  9. Presence of left atrial diverticula, accessory appendages, and normal variant pulmonary venous anatomy diagnosed using MDCT and adverse outcomes following radiofrequency catheter ablation therapy in patients with drug-refractory atrial fibrillation: An exploratory study

    International Nuclear Information System (INIS)

    Patel, S.N.; French, A.; Mathias, H.; Lyen, S.; Hamilton, M.C.K.; Manghat, N.E.

    2013-01-01

    Aim: To determine the frequency of normal variation left atrial anatomy (NVLAA) (diverticula, accessory appendages) and normal variation pulmonary venous anatomy (NVPVA) in patients with atrial fibrillation (AF), and to determine whether the presence of these entities is associated with an increased recurrence of atrial arrhythmias following radiofrequency catheter ablation (RFCA). Materials and methods: All cardiac MDCT images performed prior to RFCA between November 2009 and May 2011 in patients with drug-refractory AF were retrospectively evaluated. The presence, type, and location of NVLAA and NVPVA, and outcome of RFCA were recorded. Success was defined as restoration of sinus rhythm. Results: Forty-six consecutive patients with a mean age of 59.8 (±9.7) years (76.1% male) underwent cardiac MDCT for anatomical planning prior to RFCA procedures. Fourteen (30.4%) patients had NVLAA, 35% of patients had NVPVA. Thirty (65%) patients had successful RFCA: 57% of these had a NVLAA, 67% had NVPVA. Sixteen (35%) patients had unsuccessful RFCA: 63% of these had a NVLAA, 56% had NVPVA. There was no significant association between the presence of NVLAA (p = 0.699), NVPVA (p = 0.197), or “NVLAA in the presence of normal pulmonary venous anatomy” (p = 0.589) and the outcome of RFCA. Conclusion: The presence of NVLAA and NVPVA appears unrelated to adverse outcome in patients undergoing RFCA for the treatment of drug-refractory AF

  10. Percutaneous closure of the left atrial appendage for prevention of thromboembolism in atrial fibrillation for patients with contraindication to or failure of oral anticoagulation: a single-center experience.

    Science.gov (United States)

    Faustino, Ana; Paiva, Luís; Providência, Rui; Trigo, Joana; Botelho, Ana; Costa, Marco; Leitão-Marques, António

    2013-06-01

    In non-valvular atrial fibrillation 90% of thrombi originate in the left atrial appendage (LAA). Percutaneous LAA closure has been shown to be non-inferior to warfarin for prevention of thromboembolism. To evaluate the initial experience of a single center in percutaneous LAA closure in patients with high thromboembolic risk and in whom oral anticoagulation was impractical or contraindicated or had failed. Patients with non-valvular atrial fibrillation and CHADS2 score ≥2 in whom oral anticoagulation was impractical or contraindicated or had failed underwent percutaneous LAA closure according to the standard technique. After the procedure, dual antiplatelet therapy was maintained for one month, followed by single antiplatelet therapy indefinitely. Patients were followed by clinical assessment and transthoracic and transesophageal echocardiography. The procedure was performed in 22 of the 23 selected patients (95.7%), mean age 70±9 years, CHADS2 score 3.2±0.9 and CHA2DS2-VASC score 4.7±1.4. Intraprocedural device replacement was necessary only in the first patient, due to oversizing. The following periprocedural complications were observed: one femoral pseudoaneurysm, three femoral hematomas and two minor oropharyngeal bleeds, resolved by local hemostatic measures. During a 12±8 month follow-up a mild peri-device flow and a thrombus adhering to the device, resolved under with enoxaparin therapy, were identified. The rate of transient ischemic attack (TIA)/stroke was lower than expected according to the CHADS2 score (0 vs. 6.7±2.2%). In our initial experience, this procedure proved to be a feasible, safe and effective alternative for atrial fibrillation patients in whom oral anticoagulation is not an option. Only relatively minor complications were observed, with a lower than expected TIA/stroke rate. Copyright © 2012 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  11. Increased expression of mineralocorticoid receptor and 11beta-hydroxysteroid dehydrogenase type 2 in human atria during atrial fibrillation.

    Science.gov (United States)

    De-An, Pei; Li, Li; Zhi-Yun, Xu; Jin-Yu, Huang; Zheng-Ming, Xu; Min, Wang; Qiang, Yao; Shi-Eng, Huang

    2010-01-01

    Atrialfibrillation (AF) is associated with the activation of the renin-angiotensin-aldosterone system in the atria. It is not clear whether the expression of a mineralocorticoid receptor (MR), or 11beta-hydroxysteroid dehydrogenase type 2 (11betaHSD2), conferring aldosterone specificity to the MR, in patients with AF is altered. Patients with AF may be associated with increased expression of MR and 11betaHSD2 in the atria. Atrial tissue samples of 25 patients with rheumatic heart valve disease undergoing a valve replacement operation were examined. A total of 13 patients had chronic persistent AF (>6 mo) and 12 patients had no history of AF. The MR and 11betaHSD2 expression were analyzed at the mRNA and protein level. The localization of MR and 11betaHSD2 in atrial tissue was performed using specific immunohistochemistry staining. The results of real-time quantitative polymerase chain reaction (PCR) showed that AF groups, in comparison with sinus rhythm, had a higher mRNA expression level of MR or 11betaHSD2 (all P atrial tissue were also significantly increased in patients with AF compared with patients with sinus rhythm (P atrial interstitial fibrosis in patients with AF. These findings may have an important impact on the treatment of AF with aldosterone antagonists. Copyright 2010 Wiley Periodicals, Inc.

  12. The New 3D Printed Left Atrial Appendage Closure with a Novel Holdfast Device: A Pre-Clinical Feasibility Animal Study.

    Directory of Open Access Journals (Sweden)

    M Brzeziński

    Full Text Available Many patients undergoing cardiac surgery have risk factors for both atrial fibrillation (AF and stroke. The left atrial appendage (LAA is the primary site for thrombi formation. The most severe complication of emboli derived from LAA is stroke, which is associated with a 12-month mortality rate of 38% and a 12-month recurrence rate of 17%. The most common form of treatment for atrial fibrillation and stroke prevention is the pharmacological therapy with anticoagulants. Nonetheless this form of therapy is associated with high risk of major bleeding. Therefore LAA occlusion devices should be tested for their ability to reduce future cerebral ischemic events in patients with high-risk of haemorrhage.The aim of this study was to evaluate the safety and feasibility of a novel left atrial appendage exclusion device with a minimally invasive introducer in a swine model.A completely novel LAA device, which is composed of two tubes connected together using a specially created bail, was designed using finite element modelling (FEM to obtain an optimal support force of 36 N at the closure line. The monolithic form of the occluder was obtained by using additive manufacturing of granular PA2200 powder with the technology of selective laser sintering (SLS. Fifteen swine were included in the feasibility tests, with 10 animals undergoing fourteen days of follow-up and 5 animals undergoing long-term observation of 3 months. For one animal, the follow-up was further prolonged to 6 months. The device was placed via minithoracotomy. After the observation period, all of the animals were euthanized, and their hearts were tested for LAA closure and local inflammatory and tissue response.After the defined observation period, all fifteen hearts were explanted. In all cases the full closure of the LAA was achieved. The macroscopic and microscopic evaluation of the explanted hearts showed that all devices were securely integrated in the surrounding tissues. No

  13. Limb ischemia, an alarm signal to a thromboembolic cascade - renal infarction and nephrectomy followed by surgical suppression of the left atrial appendage.

    Science.gov (United States)

    Caraşca, Cosmin; Borda, Angela; Incze, Alexandru; Caraşca, Emilian; Frigy, Attila; Suciu, HoraŢiu

    2016-01-01

    We present the case of a 55-year-old male with mild hypertension and brief episodes of paroxysmal self-limiting atrial fibrillation (AF) since 2010. Despite a small cardioembolic risk score, CHA2DS2-Vasc=1 (Congestive heart failure, Hypertension, Age=75, Diabetes melitus, prior Stroke), the patient is effectively anticoagulated using acenocumarol. In December 2014, he showed signs of plantar transitory ischemia, for which he did not address the doctor. In early January 2015, he urgently presented at the hospital with left renal pain, caused by a renal infarction, diagnosed by computed tomography (CT) angiography. Left nephrectomy was performed with pathological confirmation. He was discharged with effective anticoagulation treatment. Within the next two weeks, he suffered a transitory ischemic event and a stroke, associated with right sided hemiparesis. On admission, AF was found and converted to sinus rhythm with effective anticoagulation - international normalized ratio (INR) of 2.12. Transthoracic echocardiography detected no pathological findings. Transesophageal echocardiography showed an expended left atrial appendage (LAA) with a slow blood flow (0.2 m÷s) and spontaneous echocontrast. Considering these clinical circumstances, surgical LAA suppression was decided on as a last therapeutic resort. Postoperative evolution was favorable; the patient is still free of ischemic events, one year post-intervention. Some morphological and hemodynamic characteristics of LAA may add additional thromboembolic risk factors, not included in scores. Removing them by surgical LAA suppression may decrease the risk of cardioembolic events. Intraoperative presence of thrombus makes it an indisputable proof.

  14. 111In-labeled platelet scintigraphy and two-dimensional echocardiography for detection of left atrial appendage thrombi. Studies in a new canine model

    International Nuclear Information System (INIS)

    Vandenberg, B.F.; Seabold, J.E.; Conrad, G.R.; Kieso, R.; Johnson, J.; Fox-Eastham, K.; Ponto, J.; Bruch, P.; Kerber, R.E.

    1988-01-01

    111In-labeled platelet scintigraphy and two-dimensional echocardiography were performed in 40 dogs to determine the ability of the two techniques to detect left atrial appendage thrombi. Thrombi were induced in 33 dogs that were classified into two groups, acute or chronic, according to the time of labeled-platelet injection after thrombus induction. In the acute group (17 dogs), platelets were injected 24 hours after thrombus induction. In the chronic group (16 dogs), platelets were injected 4-8 days after thrombus induction. Sham thoracotomies were performed on seven additional control dogs who did not receive thrombin injections. Analog and blood pool-corrected 111In-labeled platelet scintigraphy images were obtained 4-72 hours later. Closed-chest two-dimensional echocardiography was performed before thoracotomy and repeated at the time of scintigraphy. The location and size of each thrombus were verified at autopsy. Two-dimensional echocardiography detected three of 17 acute (mean volume, 1.2 +/- 1.0 cc) and three of 10 chronic (mean volume, 0.4 +/- 0.3 cc; p less than 0.025) left atrial appendage thrombi. 111In-labeled platelet scintigraphy detected all 17 acute thrombi but only two of 10 chronic thrombi. The measured radioactivity levels of the excised thrombi were 1,949 +/- 1,665 cpm/clot/dose in group 1 and 228 +/- 213 cpm/clot/dose in group 2 (p less than 0.005). In this model, 111In-labeled platelet scintigraphy was able to detect acute left atrial appendage thrombi that could not be identified by two-dimensional echocardiography. Both techniques showed poor sensitivity for detection of chronic thrombi. The decline in sensitivity of 111In-labeled platelet scintigraphy for detection of older thrombi is probably due to diminished labeled-platelet incorporation

  15. Prevention of adenosine A2A receptor activation diminishes beat-to-beat alternation in human atrial myocytes.

    Science.gov (United States)

    Molina, Cristina E; Llach, Anna; Herraiz-Martínez, Adela; Tarifa, Carmen; Barriga, Montserrat; Wiegerinck, Rob F; Fernandes, Jacqueline; Cabello, Nuria; Vallmitjana, Alex; Benitéz, Raúl; Montiel, José; Cinca, Juan; Hove-Madsen, Leif

    2016-01-01

    Atrial fibrillation (AF) has been associated with increased spontaneous calcium release from the sarcoplasmic reticulum and linked to increased adenosine A2A receptor (A2AR) expression and activation. Here we tested whether this may favor atrial arrhythmogenesis by promoting beat-to-beat alternation and irregularity. Patch-clamp and confocal calcium imaging was used to measure the beat-to-beat response of the calcium current and transient in human atrial myocytes. Responses were classified as uniform, alternating or irregular and stimulation of Gs-protein coupled receptors decreased the frequency where a uniform response could be maintained from 1.0 ± 0.1 to 0.6 ± 0.1 Hz; p < 0.01 for beta-adrenergic receptors and from 1.4 ± 0.1 to 0.5 ± 0.1 Hz; p < 0.05 for A2ARs. The latter was linked to increased spontaneous calcium release and after-depolarizations. Moreover, A2AR activation increased the fraction of non-uniformly responding cells in HL-1 myocyte cultures from 19 ± 3 to 51 ± 9 %; p < 0.02, and electrical mapping in perfused porcine atria revealed that adenosine induced electrical alternans at longer cycle lengths, doubled the fraction of electrodes showing alternation, and increased the amplitude of alternations. Importantly, protein kinase A inhibition increased the highest frequency where uniform responses could be maintained from 0.84 ± 0.12 to 1.86 ± 0.11 Hz; p < 0.001 and prevention of A2AR-activation with exogenous adenosine deaminase selectively increased the threshold from 0.8 ± 0.1 to 1.2 ± 0.1 Hz; p = 0.001 in myocytes from patients with AF. In conclusion, A2AR-activation promotes beat-to-beat irregularities in the calcium transient in human atrial myocytes, and prevention of A2AR activation may be a novel means to maintain uniform beat-to-beat responses at higher beating frequencies in patients with atrial fibrillation.

  16. Effect of renin-angiotensin -aldosterone system blockers on myocardial remodeling processes and risk for atrial fibrillation in patients with arterial hypertension

    Directory of Open Access Journals (Sweden)

    O. M. Drapkina

    2014-07-01

    Full Text Available The given review considers the mechanisms underlying the development and maintenance of atrial fibrillations (AF. It is noted that the processes of atrial fibrosis, ion channel remodeling, inflammation, apoptosis, impaired intercellular interactions, and myocardiocyte hypertrophy may give rise to atrial structural and functional changes in AF. The efficacy of angiotensinonverting enzyme inhibitors and angiotensin receptor antagonists is justified in patients with left ventricular systolic dysfunction.

  17. Long-term follow-up of patients with paroxysmal atrial fibrillation and severe left atrial scarring: comparison between pulmonary vein antrum isolation only or pulmonary vein isolation combined with either scar homogenization or trigger ablation.

    Science.gov (United States)

    Mohanty, Sanghamitra; Mohanty, Prasant; Di Biase, Luigi; Trivedi, Chintan; Morris, Eli Hamilton; Gianni, Carola; Santangeli, Pasquale; Bai, Rong; Sanchez, Javier E; Hranitzky, Patrick; Gallinghouse, G Joseph; Al-Ahmad, Amin; Horton, Rodney P; Hongo, Richard; Beheiry, Salwa; Elayi, Claude S; Lakkireddy, Dhanunjaya; Madhu Reddy, Yaruva; Viles Gonzalez, Juan F; Burkhardt, J David; Natale, Andrea

    2017-11-01

    Left atrial (LA) scarring, a consequence of cardiac fibrosis is a powerful predictor of procedure-outcome in atrial fibrillation (AF) patients undergoing catheter ablation. We sought to compare the long-term outcome in patients with paroxysmal AF (PAF) and severe LA scarring identified by 3D mapping, undergoing pulmonary vein isolation (PVAI) only or PVAI and the entire scar areas (scar homogenization) or PVAI+ ablation of the non-PV triggers. Totally, 177 consecutive patients with PAF and severe LA scarring were included. Patients underwent PVAI only (n = 45, Group 1), PVAI+ scar homogenization (n = 66, Group 2) or PVAI+ ablation of non-PV triggers (n = 66, Group 3) based on operator's choice. Baseline characteristics were similar across the groups. After first procedure, all patients were followed-up for a minimum of 2 years. The success rate at the end of the follow-up was 18% (8 pts), 21% (14 pts), and 61% (40 pts) in Groups 1, 2, and 3, respectively. Cumulative probability of AF-free survival was significantly higher in Group 3 (overall log-rank P homogenization. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For Permissions, please email: journals.permissions@oup.com.

  18. Left Atrial Deformation Analysis in Patients with Corrected Tetralogy of Fallot by 3D Speckle-Tracking Echocardiography (from the MAGYAR-Path Study

    Directory of Open Access Journals (Sweden)

    Kálmán Havasi

    Full Text Available Abstract Background: Three-dimensional (3D echocardiography coupled with speckle-tracking echocardiographic (STE capability is a novel methodology which has been demontrated to be useful for the assessment of left atrial (LA volumes and functional properties. There is increased scientific interest on myocardial deformation analysis in adult patients with corrected tetralogy of Fallot (cTOF. Objectives: To compare LA volumes, volume-based functional properties and strain parameters between cTOF patients and age- and gender-matched healthy controls. Methods: The study population consisted of 19 consecutive adult patients with cTOF in sinus rhythm nursing at the University of Szeged, Hungary (mean age: 37.9 ± 11.3 years, 8 men, who had repair at the age of 4.1 ± 2.5 years. They all had undergone standard transthoracic two-dimensional Doppler echocardiographic study extended with 3DSTE. Their results were compared to 23 age- and gender-matched healthy controls (mean age: 39.2 ± 10.6 years, 14 men. Results: Increased LA volumes and reduced LA emptying fractions respecting cardiac cycle could be demonstrated in cTOF patients compared to controls. LA stroke volumes featuring all LA functions showed no differences between the 2 groups examined. LA global and mean segmental uni- and multidirectional peak strains featuring LA reservoir function were found to be diminished in adult patients with cTOF as compared to controls. Similarly to peak strains reduced global and mean segmental LA strains at atrial contraction characterizing atrial booster pump function could be demonstrated in cTOF patients as compared to controls. Conclusions: Significant deterioration of all LA functions could be demonstrated in adult patients with cTOF late after repair.

  19. Left Atrial Deformation Analysis in Patients with Corrected Tetralogy of Fallot by 3D Speckle-Tracking Echocardiography (from the MAGYAR-Path Study)

    Science.gov (United States)

    Havasi, Kálmán; Domsik, Péter; Kalapos, Anita; McGhie, Jackie S.; Roos-Hesselink, Jolien W.; Forster, Tamás; Nemes, Attila

    2017-01-01

    Background Three-dimensional (3D) echocardiography coupled with speckle-tracking echocardiographic (STE) capability is a novel methodology which has been demontrated to be useful for the assessment of left atrial (LA) volumes and functional properties. There is increased scientific interest on myocardial deformation analysis in adult patients with corrected tetralogy of Fallot (cTOF). Objectives To compare LA volumes, volume-based functional properties and strain parameters between cTOF patients and age- and gender-matched healthy controls. Methods The study population consisted of 19 consecutive adult patients with cTOF in sinus rhythm nursing at the University of Szeged, Hungary (mean age: 37.9 ± 11.3 years, 8 men, who had repair at the age of 4.1 ± 2.5 years). They all had undergone standard transthoracic two-dimensional Doppler echocardiographic study extended with 3DSTE. Their results were compared to 23 age- and gender-matched healthy controls (mean age: 39.2 ± 10.6 years, 14 men). Results Increased LA volumes and reduced LA emptying fractions respecting cardiac cycle could be demonstrated in cTOF patients compared to controls. LA stroke volumes featuring all LA functions showed no differences between the 2 groups examined. LA global and mean segmental uni- and multidirectional peak strains featuring LA reservoir function were found to be diminished in adult patients with cTOF as compared to controls. Similarly to peak strains reduced global and mean segmental LA strains at atrial contraction characterizing atrial booster pump function could be demonstrated in cTOF patients as compared to controls. Conclusions Significant deterioration of all LA functions could be demonstrated in adult patients with cTOF late after repair. PMID:28327874

  20. Comparison of determinations of left atrial volume by the biplane area-length and Simpson's methods using 64-slice computed tomography

    International Nuclear Information System (INIS)

    Takagi, Yasuhiro; Ehara, Shoichi; Okuyama, Takuhiro

    2009-01-01

    There is increasing evidence that left atrial (LA) size is an important predictor of adverse cardiovascular outcomes such as atrial fibrillation, stroke, and congestive heart failure. The aim of this study was to determine whether there is a difference in results of quantification of LA volume by the area-length and Simpson's methods using multislice computed tomography (MSCT). The study population consisted of 51 patients with sinus rhythm (sinus group) and 20 patients with atrial fibrillation (af group) clinically indicated for MSCT angiography for evaluation of coronary arteries. Maximum LA volume, obtained at end-systole from the phase immediately preceding mitral valve opening, was measured using the area-length and Simpson's methods. In the sinus group, the mean LA volumes, indexed to body surface area, were 48.4±17.9 ml/m 2 with the area-length method and 48.3±17.0 ml/m 2 with the Simpson's method. In the af group, the mean indexed LA volumes with the area-length method and the Simposon's method were 91.5±47.5 ml/m 2 and 90.3±45.9 ml/m 2 , respectively. LA volumes calculated by the area-length method exhibited a strong linear relationship and agreement with those calculated using Simpson's method in both the groups (sinus group: r=0.99, P<0.0001, af group: r=0.99, P<0.0001). The area-length method is a simple and reproducible means of assessment of LA volume. Standardization of LA volume assessment using MSCT is important for serial follow-up and meaningful communication of results of testing among institutions and physicians. (author)

  1. TRIF promotes angiotensin II-induced cross-talk between fibroblasts and macrophages in atrial fibrosis

    International Nuclear Information System (INIS)

    Chen, Xiao-Qing; Zhang, Dao-Liang; Zhang, Ming-Jian; Guo, Meng; Zhan, Yang-Yang; Liu, Fang; Jiang, Wei-Feng; Zhou, Li; Zhao, Liang; Wang, Quan-Xing; Liu, Xu

    2015-01-01

    Aims: Atrial fibroblasts and macrophages have long been thought to participate in atrial fibrillation (AF). However, which specific mediator may regulate the interaction between them remains unclear. Methods and results: We provided the evidence for the involvement of Toll/IL-1 receptor domain-containing adaptor inducing IFN-β (TRIF), an important inflammation-related molecule, in the pathophysiology of AF. Patients with AF showed higher levels of angiotensin II (AngII) and TRIF expression and larger number of macrophages infiltration in left atria appendage than individuals with sinus rhythm (SR). In the cell study, AngII induced chemokines expressions in mouse atrial fibroblasts and AngII-stimulated atrial fibroblasts induced the chemotaxis of macrophages, which were reduced by losartan and TRIF siRNA. Meanwhile, AngII-stimulated atrial fibroblasts proliferation was enhanced by macrophages. Conclusions: Our data demonstrated that TRIF may be a crucial factor promoting the interaction between atrial fibroblasts and macrophages, leading to atrial fibrosis. - Highlights: • Compared with SR, AF showed higher TRIF expression in left atrial appendage. • TRIF siRNA reversed macrophage chemotaxis induced by AngII-treated fibroblast. • TRIF siRNA reversed chemokines expressions induced by AngII in fibroblast. • AngII-stimulated atrial fibroblast proliferation was enhanced by macrophage

  2. TRIF promotes angiotensin II-induced cross-talk between fibroblasts and macrophages in atrial fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Xiao-Qing; Zhang, Dao-Liang [Department of Cardiology, Shanghai Chest Hospital, Shanghai Jiaotong University, Shanghai (China); Zhang, Ming-Jian; Guo, Meng; Zhan, Yang-Yang; Liu, Fang [National Key Laboratory of Medical Immunology, Second Military Medical University, Shanghai (China); Jiang, Wei-Feng; Zhou, Li [Department of Cardiology, Shanghai Chest Hospital, Shanghai Jiaotong University, Shanghai (China); Zhao, Liang, E-mail: zhaol_zg@163.com [Department of Cardiology, Shanghai Chest Hospital, Shanghai Jiaotong University, Shanghai (China); Wang, Quan-Xing, E-mail: wqxejd@126.com [National Key Laboratory of Medical Immunology, Second Military Medical University, Shanghai (China); Liu, Xu, E-mail: liuxu_xk@163.com [Department of Cardiology, Shanghai Chest Hospital, Shanghai Jiaotong University, Shanghai (China)

    2015-08-14

    Aims: Atrial fibroblasts and macrophages have long been thought to participate in atrial fibrillation (AF). However, which specific mediator may regulate the interaction between them remains unclear. Methods and results: We provided the evidence for the involvement of Toll/IL-1 receptor domain-containing adaptor inducing IFN-β (TRIF), an important inflammation-related molecule, in the pathophysiology of AF. Patients with AF showed higher levels of angiotensin II (AngII) and TRIF expression and larger number of macrophages infiltration in left atria appendage than individuals with sinus rhythm (SR). In the cell study, AngII induced chemokines expressions in mouse atrial fibroblasts and AngII-stimulated atrial fibroblasts induced the chemotaxis of macrophages, which were reduced by losartan and TRIF siRNA. Meanwhile, AngII-stimulated atrial fibroblasts proliferation was enhanced by macrophages. Conclusions: Our data demonstrated that TRIF may be a crucial factor promoting the interaction between atrial fibroblasts and macrophages, leading to atrial fibrosis. - Highlights: • Compared with SR, AF showed higher TRIF expression in left atrial appendage. • TRIF siRNA reversed macrophage chemotaxis induced by AngII-treated fibroblast. • TRIF siRNA reversed chemokines expressions induced by AngII in fibroblast. • AngII-stimulated atrial fibroblast proliferation was enhanced by macrophage.

  3. Surgery for atrial fibrillation.

    Science.gov (United States)

    Viganò, M; Graffigna, A; Ressia, L; Minzioni, G; Pagani, F; Aiello, M; Gazzoli, F

    1996-01-01

    The mechanisms of atrial fibrillation arc multiple reentry circuits spinning around the atrial surface, and these baffle any attempt to direct surgical interruption. The purpose of this article is to report the surgical experience in the treatment of isolated and concomitant atrial fibrillation at the Cardiac Surgical Institute of the University of Pavia. In cases of atrial fibrillation secondary to mitral/valve disease, surgical isolation of the left atrium at the time of mitral valve surgery can prevent atrial fibrillation from involving the right atrium, which can exert its diastolic pump function on the right ventricle. Left atrial isolation was performed on 205 patients at the time of mitral valve surgery. Atrial partitioning ("maze operation") creates straight and blind atrial alleys so that non-recentry circuits can take place. Five patients underwent this procedure. In eight-cases of atrial fibrillation secondary to atrial septal defect, the adult patients with atrial septal defect and chronic or paroxysmal atrial fibrillation underwent surgical isolation of the right atrium associated which surgical correction of the defect, in order to let sinus rhythm govern the left atrium and the ventricles. "Lone" atrial fibrillation occurs in hearts with no detectable organic disease. Bi-atrial isolation with creation of an atrial septal internodal "corridor" was performed on 14 patients. In cases of atrial fibrillation secondary to mitral valve disease, left atrial isolation was performed on 205 patients at the time of mitral valve surgery with an overall sinus rhythm recovery of 44%. In the same period, sinus rhythm was recovered and persisted in only 19% of 252 patients who underwent mitral valve replacement along (P < 0.001). Sinus rhythm was less likely to recover in patients with right atriomegaly requiring tricuspid valve annuloplasty: 59% vs 84% (P < 0.001). Restoration of the right atrial function raised the cardiac index from 2.25 +/- 0.55 1/min per m2

  4. Coronary artery disease, left ventricular hypertrophy and diastolic dysfunction are associated with stroke in patients affected by persistent non-valvular atrial fibrillation: a case-control study

    Directory of Open Access Journals (Sweden)

    Andrea Passantino

    2009-04-01

    Full Text Available Persistent non-valvular atrial fibrillation (NVAF is associated with an increased risk of cardiovascular events such as stroke, and its rate is expected to rise because of the ageing population. The absolute rate of stroke depends on age and comorbidity. Risk stratification for stroke in patients with NVAF derives from populations enrolled in randomized clinical trials. However, participants in clinical trials are often not representative of the general population. Many stroke risk stratification scores have been used, but they do not include transthoracic echocardiogram (TTE, pulsate wave Doppler (PWD and tissue Doppler imaging (TDI, simple and non-invasive diagnostic tools. The role of TTE, PWD and TDI findings has not been previously determined. Our study goal was to determine the association between TTE and PWD findings and stroke prevalence in a population of NVAF prone outpatients. Patients were divided into two groups: P for stroke prone and F for stroke free. There were no statistically significant differences between the two groups concerning cardiovascular risk factors, age (p=0.2, sex (p=0.2, smoking (p=0.3, diabetes (p=0.1 and hypercholesterolemia (p=0.2; hypertension was statistically significant (p less than 0.001. There were statistically significant differences concerning coronary artery disease, previous acute myocardial infarction (AMI (p less than 0.05 and non- AMI coronaropathy (p less than 0.04, a higher rate being in the P group. Concerning echo-Doppler findings, a higher statistically significant rate of left ventricular hypertrophy (LVH (p less than  0.05 and left ventricular diastolic dysfunction (p less than 0.001 was found in the P group and dilated left atrium (p Higher levels of serum fibrin-monomer reflect hypercoagulable state and thrombus formation in the left atrial appendage in patients with acute ischemic stroke.

    Science.gov (United States)

    Okuyama, Hidenobu; Hirono, Osamu; Liu, Ling; Takeishi, Yasuchika; Kayama, Takamasa; Kubota, Isao

    2006-08-01

    It is sometimes difficult to make a diagnosis of cardioembolic stroke in the stroke care unit, because of the splashing and vanishing of the intracardiac source of the emboli on transesophageal echocardiography. Serum fibrin-monomer (FM) is a new marker for coagulation activity that is useful for identifying older individuals at increased risk of ischemic stroke. Two hundred and four patients with acute ischemic stroke were examined for serum coagulation and fibrinolytic activity on admission, and underwent transesophageal echocardiography within 7 days of onset. Serum levels of FM was significantly higher in patients with left atrial appendage (LAA) thrombus formation (n=24) than in those with no thrombus (88+/-52 vs 14+/-9 microg/ml, pvs 8+/-5 microg/ml, pstroke.

  5. [Echocardiographic diagnosis of atrial thrombosis].

    Science.gov (United States)

    Pinto Tortolero, R; Vargas Barrón, J; Rodas, M A; Díaz de la Vega, V; Horwitz, S

    1982-01-01

    Seventy patients with rheumatic mitral disease were studied by M-Mode and 2D echocardiography in order to detect left atrial thrombosis before surgery. Thrombosis were suspected by the observation of abnormal echoes in the left atrium. During surgery 17 (24%) patients had atrial thrombosis. It had been suspected by echocardiography in 12 (sensitivity 70%). In 53 patients thrombosis were not found during surgery; in 46 the echo had been also negative (specificity 86%). There was a false positive detection of thrombosis by echo in 7 patients (14%) and false negativity in 5 (30%). Patients with atrial thrombosis had atrial fibrilation in 91% of cases; and the most frequent valvular disease was mitral stenosis. There was not a direct relationship among existence of left atrial thrombosis and the anteroposterior diameter of the left atrium as measured by echo. We conclude that echocardiography has good specificity to rule out atrial thrombosis and moderate sensitivity to detect it in rheumatic mitral disease.

  6. Multimodal Examination of Atrial Fibrillation Substrate: Correlation of Left Atrial Bipolar Voltage Using Multi-Electrode Fast Automated Mapping, Point-by-Point Mapping, and Magnetic Resonance Image Intensity Ratio.

    Science.gov (United States)

    Zghaib, Tarek; Keramati, Ali; Chrispin, Jonathan; Huang, Dong; Balouch, Muhammad A; Ciuffo, Luisa; Berger, Ronald D; Marine, Joseph E; Ashikaga, Hiroshi; Calkins, Hugh; Nazarian, Saman; Spragg, David D

    2018-01-01

    Bipolar voltage mapping, as part of atrial fibrillation (AF) ablation, is traditionally performed in a point-by-point (PBP) approach using single-tip ablation catheters. Alternative techniques for fibrosis-delineation include fast-anatomical mapping (FAM) with multi-electrode circular catheters, and late gadolinium-enhanced magnetic-resonance imaging (LGE-MRI). The correlation between PBP, FAM, and LGE-MRI fibrosis assessment is unknown. In this study, we examined AF substrate using different modalities (PBP, FAM, and LGE-MRI mapping) in patients presenting for an AF ablation. LGE-MRI was performed pre-ablation in 26 patients (73% males, age 63±8years). Local image-intensity ratio (IIR) was used to normalize myocardial intensities. PBP- and FAM-voltage maps were acquired, in sinus rhythm, prior to ablation and co-registered to LGE-MRI. Mean bipolar voltage for all 19,087 FAM voltage points was 0.88±1.27mV and average IIR was 1.08±0.18. In an adjusted mixed-effects model, each unit increase in local IIR was associated with 57% decrease in bipolar voltage (p0.74 corresponded to bipolar voltage voltage was significantly associated with log-PBP bipolar voltage (ß=0.36, pvoltages, FAM-mapping distribution was shifted to the left compared to PBP-mapping; at intermediate voltages, FAM and PBP voltages were overlapping; and at high voltages, FAM exceeded PBP-voltages. LGE-MRI, FAM and PBP-mapping show good correlation in delineating electro-anatomical AF substrate. Each approach has fundamental technical characteristics, the awareness of which allows proper assessment of atrial fibrosis.

  7. Left atrial volume and function in patients following ST elevation myocardial infarction and the association with clinical outcome

    DEFF Research Database (Denmark)

    Lønborg, Jacob Thomsen; Engstrøm, Thomas; Møller, Jacob Eifer

    2013-01-01

    The left atrium (LA) transfers blood to the left ventricle in a complex manner. LA function is characterized by passive emptying (LA passive fraction), active emptying (LA ejection fraction), and total emptying (LA fractional change). Despite this complexity, the clinical relevance of the LA is b...... function in patients following ST elevation myocardial infarction (STEMI)....

  8. Atrial natriuretic factor receptor guanylate cyclase, ANF-RGC, transduces two independent signals, ANF and Ca2+

    Directory of Open Access Journals (Sweden)

    Teresa eDuda

    2014-03-01

    Full Text Available Atrial natriuretic factor receptor guanylate cyclase, ANF-RGC, was the first discovered member of the mammalian membrane guanylate cyclase family. The hallmark feature of the family is that a single protein contains both the site for recognition of the regulatory signal and the ability to transduce it into the production of the second messenger, cyclic GMP. For over two decades, the family has been classified into two subfamilies, the hormone receptor subfamily with ANF-RGC being its paramount member, and the Ca2+ modulated subfamily, which includes the rod outer segment guanylate cyclases, ROS-GC1 and 2, and the olfactory neuroepithelial guanylate cyclase, ONE-GC. ANF-RGC is the receptor and the signal transducer of the most hypotensive hormones, atrial natriuretic factor (ANF and B-type natriuretic peptide (BNP. After binding these hormones at the extracellular domain it, at its intracellular domain, signals activation of the C-terminal catalytic module and accelerates the production of cyclic GMP. Cyclic GMP then serves the second messenger role in biological responses of ANF and BNP such as natriuresis, diuresis, vasorelaxation and anti-proliferation. Very recently another modus operandi for ANF-RGC was revealed. Its crux is that ANF-RGC activity is also regulated by Ca2+. The Ca2+ sensor neurocalcin  mediates this signaling mechanism. Strikingly, the Ca2+ and ANF signaling mechanisms employ separate structural motifs of ANF-RGC in modulating its core catalytic domain in accelerating the production of cyclic GMP. In this review the biochemistry and physiology of these mechanisms with emphasis on cardiovascular regulation will be discussed.

  9. Changes in Serum NT-Pro BNP and Left Atrial BNP Levels after Percutaneous Transvenous Mitral Commissurotomy in Sinus Rhythm Versus Atrial Firilation

    Directory of Open Access Journals (Sweden)

    Leili Pourafkari

    2014-10-01

    Full Text Available Introduction: Natriuretic peptides are secreted from the heart in response to increased wall stress. Their levels are expected to be increased in patients with mitral stenosis (MS due tohigh left atrium (LA pressure and pulmonary artery pressure (PAP. Percutaneous transvenousmitral commissurotomy (PTMC if successful is pursued by a rapid decrease in LA pressure andsubsequent decrease in pulmonary artery pressure. The concurrent changes in natriuretic peptidelevels could be affected with heart rhythm.Methods: Forty five patients with severe rheumatic MS undergoing PTMC were enrolled. Weevaluated the serum NT-Pro BNP levels before and 24 hours after PTMC. BNP levels were alsomeasured from the blood samples obtained from LA before and 20 minutes after the procedure.Changes in biomarkers were assessed based on heart rhythm and success of the procedure.Results: While serum NT-Pro BNP levels showed significant decrease 24 hours after theprocedure (P= 0.04, BNP levels taken 20 minutes after PTMC from LA were similar to theirbaseline concentrations (P= 0.26. NT-Pro BNP levels decreased 51.7±182.86 pg/ml for SR and123.4±520 pg/ml for AF (P= 0.68.Conclusion: Immediate changes in BNP levels did not predict the success of procedure probablydue to the additional balloon inflation attempts in LA in several patients and half-life of BNP. BNPlevels obtained later may be of more value considering the half-life of this marker. Heart rhythmwas not found to influence the changes in biomarker levels. BNP and NT-pro BNP changes werenot found to predict success of the procedure.

  10. The role of Multidetector CT in the evaluation of the left atrium and pulmonary veins anatomy before and after radio-frequency catheter ablation for atrial fibrillation. Preliminary results and work in progress.Technical note

    International Nuclear Information System (INIS)

    Centoze, Maurizio; Della Sala, Sabino Walter; Dalla Palma, Francesco; Del Greco, Maurizio; Marini, Massimiliano; Nollo, Giandomenico; Ravelli, Flavia

    2005-01-01

    Radio-frequency catheter ablation (RFCA) of the distal pulmonary veins is increasingly being used to treat recurrent or refractory atrial fibrillation that doesn't respond to pharmacologic therapy or cardioversion. Successful RFCA of atrial al fibrillation depends on the pre-procedural understanding of the complex anatomy of the distal pulmonary veins and the left atrium. Aim of this parer is to describe the technical main features that characterise the multidetector helical computed tomography in the evaluation of this anatomic region before and after RFCA procedure. The 3D post-processing techniques useful for pre-RFCA planning are straightforward [it

  11. Traumatic tricuspid regurgitation and right-to-left intra-atrial shunt--an unusual complication of a horse-kick.

    LENUS (Irish Health Repository)

    Byrne, R A

    2010-02-01

    A 63-year-old male presented with sudden onset chest pain and dyspnoea following a kick to the praecordium while gelding a horse. Transthoracic echocardiography showed evidence of flail tricuspid valve leaflets, severe tricuspid regurgitation and a widely patent foramen ovale with a right-to-left shunt. Due to progressive severe systemic hypoxemia the patient underwent emergent surgical intervention. Operative findings confirmed rupture of the anterior and septal tricuspid valve papillary muscles. Successful papillary muscle reattachment was performed in association with tricuspid annuloplasty and suture closure of his patent foramen ovale. Disruption of the tricuspid valve is well described as consequence of blunt trauma to the chest wall and is often well tolerated, coming to light many years post injury. Valve disruption due to rupture at the papillary muscle level, however, typically results in greater severity of tricuspid regurgitation and the abrupt rise in right intra-atrial pressure may lead to a right-to-left shunt across a patent foramen ovale. Where hemodynamic compromise ensues, prompt surgical intervention is mandated.

  12. Assessment of left atrial appendage function by transthoracic pulsed Doppler echocardiography: Comparing against transesophageal interrogation and predicting echocardiographic risk factors for stroke.

    Science.gov (United States)

    Wai, Shin Hnin; Kyu, Kyu; Galupo, Mary Joyce; Songco, Geronica G; Kong, William K F; Lee, Chi Hang; Yeo, Tiong Cheng; Poh, Kian Keong

    2017-10-01

    Transesophageal echocardiographic (TEE) findings of left atrial appendage (LAA) thrombus, spontaneous echo contrast (SEC), and LAA dysfunction are established risk factors of cardioembolic stroke. The semi-invasive nature of TEE limits its utility as a routine risk stratification tool. We aim to correlate TEE and transthoracic echocardiography (TTE) pulsed Doppler measurements of LAA flow velocities and use TTE measurements to predict TEE findings. We prospectively measured pulsed Doppler LAA flow velocities in 103 consecutive patients on TEE and TTE. There was a strong correlation between TEE and TTE LAA emptying velocity (LAA E) (r = .88, P < .001) and a moderate correlation between LAA filling velocities (r = .50, P < .001). TTE LAA E predicted the presence of thrombus or SEC independent of atrial fibrillation (AF). To predict the presence of thrombus or SEC, the optimal TTE LAA E cutoff was ≤30 cm/s in all patients (75% sensitive, 90% specific) and ≤31 cm/s in AF patients (80% sensitive, 79% specific). To predict LAA dysfunction (TEE E ≤ 20 cm/s), the optimal TTE LAA E cutoff was ≤27 cm/s (100% sensitive, 89% specific in all patients and 100% sensitive, 74% specific in AF patients). TTE assessment of LAA function is feasible and correlates well with the more invasive TEE method. It predicts the presence of thrombus, SEC, and LAA dysfunction on TEE. TTE LAA assessment has incremental value in thromboembolic risk stratification and should be utilized more frequently. © 2017, Wiley Periodicals, Inc.

  13. Frequency of left atrial thrombus detected by transesophageal echocardiography in patients of tight mitral stenosis having negative trans-thoracic echocardiography at gulab devi cardiac complex

    International Nuclear Information System (INIS)

    Fayyaz, A.; Iqbal, M.W.

    2014-01-01

    Introduction: Patients with mitral stenosis (MS) having atrial fibrillation (AF) are more prone to develop left atrial (LA) thrombus. Systemic embolism, related to LA thrombus is a well-known risk of Percutaneous Mitral Balloon Valvotomy (PMBV) of the mitral valve. Therefore presence of LA thrombus is a contraindication to PMBV. Objective: Objective of this study was to detect the frequency of LA thrombus by transesophageal echocardiography (TEE) in patients of tight MS in whom transthoracic echocardiography (TTE) could not detect any LA thrombus. Patients and Methods: In this cross sectional study, we took 100 indoor patients with tight MS on non-probability consecutive sampling. Data was collected after meeting inclusion criteria. Patients were taken in this study after acquiring written informed consent. Symptoms were inquired from all patients and functional status was assessed by New York Heart Association class. Unstable patients were medically managed before the procedure. TEE was done on the same day before undergoing PMBV to look for clot in LA. Results: The mean age of the patients was 32.20 years and SD was 11.3 years. There were 36(36%) male patients and 64(64%) female patients. LA thrombus was present in 40% of patients on TEE out of which 19 were male patients (52.77%) and 21 were female patients (32.81%). Conclusion: Patients with mitral stenosis having AF are more prone to develop LA thrombus. In this study, the frequency of LA thrombus was 40% recorded, which is high. Due to the potential risk of embolization, it is strongly recommended to perform TEE in patients with normal TTE study before undergoing PMBV. The presence of a LA thrombus should be considered a contraindication to the PMBV of the mitral valve. (author)

  14. Cirurgia cardíaca de emergência para ressecção de mixoma atrial esquerdo Cardiac surgery of emergency for resection of left atrial myxoma

    Directory of Open Access Journals (Sweden)

    Antônio Augusto Ramalho Motta

    2008-06-01

    Full Text Available É descrito caso de paciente do sexo feminino que apresentava manifestações pulmonares e sistêmicas inespecíficas há vários meses, as quais resultaram em várias internações hospitalares com a hipótese diagnóstica de fibrose pulmonar. Estudo ecocardiográfico evidenciou a presença de grande mixoma pediculado no átrio esquerdo, que prolapsava, através da valva mitral, para o ventrículo esquerdo. Em condições clínicas bastante desfavoráveis, a paciente foi encaminhada ao nosso Serviço para tratamento cirúrgico, evoluindo durante o preparo pré-operatório com edema agudo pulmonar e instabilidade hemodinâmica, sendo submetida a cirurgia de emergência, com sucesso, para ressecção da tumoração. A paciente encontra-se assintomática.We report case of a female patient who during months presented pulmonary manifestation associated with nonspecific systemic symptoms resulting in several hospitalizations with the diagnostic hypothesis of pulmonary fibrosis. The echocardiographic study showed a great pedunculated left atrial myxoma prolapsing through the mitral valve for the left ventricle. In quite unfavorable clinical conditions the patient was sent to our Service for surgical treatment, evolving during the preparation for surgery with acute pulmonary edema and hemodinamic instability being submitted to a successfully surgery of emergency for resection of the tumor. The patient is asymptomatic.

  15. The impact of the CartoSound® image directly acquired from the left atrium for integration in atrial fibrillation ablation.

    Science.gov (United States)

    Kaseno, Kenichi; Hisazaki, Kaori; Nakamura, Kohki; Ikeda, Etsuko; Hasegawa, Kanae; Aoyama, Daisetsu; Shiomi, Yuichiro; Ikeda, Hiroyuki; Morishita, Tetsuji; Ishida, Kentaro; Amaya, Naoki; Uzui, Hiroyasu; Tada, Hiroshi

    2018-04-14

    Intracardiac echocardiographic (ICE) imaging might be useful for integrating three-dimensional computed tomographic (CT) images for left atrial (LA) catheter navigation during atrial fibrillation (AF) ablation. However, the optimal CT image integration method using ICE has not been established. This study included 52 AF patients who underwent successful circumferential pulmonary vein isolation (CPVI). In all patients, CT image integration was performed after the CPVI with the following two methods: (1) using ICE images of the LA derived from the right atrium and right ventricular outflow tract (RA-merge) and (2) using ICE images of the LA directly derived from the LA added to the image for the RA-merge (LA-merge). The accuracy of these two methods was assessed by the distances between the integrated CT image and ICE image (ICE-to-CT distance), and between the CT image and actual ablated sites for the CPVI (CT-to-ABL distance). The mean ICE-to-CT distance was comparable between the two methods (RA-merge = 1.6 ± 0.5 mm, LA-merge = 1.7 ± 0.4 mm; p = 0.33). However, the mean CT-to-ABL distance was shorter for the LA-merge (2.1 ± 0.6 mm) than RA-merge (2.5 ± 0.8 mm; p imaging, and whereas the greatest CT-to-ABL distance was observed at the roof portion of the left superior PV (3.7 ± 2.8 mm) after the RA-merge, it improved to 2.6 ± 1.9 mm after the LA-merge (p images of the LA directly acquired from the LA might lead to a greater accuracy of the CT image integration for the CVPI.

  16. Atrial Fibrillation and Hyperthyroidism

    Directory of Open Access Journals (Sweden)

    Jayaprasad N

    2005-10-01

    Full Text Available Atrial fibrillation occurs in 10 – 15% of patients with hyperthyroidism. Low serum thyrotropin concentration is an independent risk factor for atrial fibrillation. Thyroid hormone contributes to arrythmogenic activity by altering the electrophysiological characteristics of atrial myocytes by shortening the action potential duration, enhancing automaticity and triggered activity in the pulmonary vein cardio myocytes. Hyperthyroidism results in excess mortality from increased incidence of circulatory diseases and dysrhythmias. Incidence of cerebral embolism is more in hyperthyroid patients with atrial fibrillation, especially in the elderly and anti-coagulation is indicated in them. Treatment of hyperthyroidism results in conversion to sinus rhythm in up to two-third of patients. Beta-blockers reduce left ventricular hypertrophy and atrial and ventricular arrhythmias in patients with hyperthyroidism. Treatment of sub clinical hyperthyroidism is controversial. Optimizing dose of thyroxine treatment in those with replacement therapy and beta-blockers is useful in exogenous subclinical hyperthyroidism.

  17. Long-term fate of left atrial thrombi and incidence of cerebral embolism under continuous anticoagulation therapy; MR-tomographische Evaluation der Inzidenz zerebraler Embolien bei Patienten mit Vorhofflimmern und linksatrialen Thromben

    Energy Technology Data Exchange (ETDEWEB)

    Strach, K.; Meyer, C.; Hackenbroch, M.; Schild, H.; Sommer, T. [Radiologische Universitaetsklinik Bonn (Germany); Tiemann, K. [Medizinische Universitaetsklinik und Poliklinik II, Bonn (Germany); Haase, J. [Klinik Rotes Kreuz, Frankfurt/Main (Germany); Pizulli, L. [Petruskrankenhaus, Bonn (Germany); Omran, H. [St. Marien-Hospital, Bonn (Germany)

    2005-12-15

    Purpose: Patients (pts.) with atrial fibrillation (AF) and atrial thrombi are known to have an increased risk for cerebral embolism. However, little is known about the clinical course of atrial thrombi and the incidence of cerebral embolism in those patients during anticoagulation therapy. The high sensitivity of MR imaging (MRI) including diffusion-weighted imaging (DWI) suggests that this technique could provide an improved estimate of cerebral embolism associated with the presence of left atrial thrombi. The aims of this prospective study were to evaluate (1) the prevalence of clinically silent and apparent cerebral embolism in pts. with newly diagnosed AF and atrial thrombi using MRI/DWI, (2) the long-term fate of atrial thrombi under continued anticoagulation therapy and (3) the incidence of cerebral embolism during a follow-up period of 12 months with continuous anticoagulation therapy. Materials and methods: The study group consisted of 32 pts. with (1) newly diagnosed AF and evidence of left atrial (LA) thrombi detected by TEE and (2) a new start of anticoagulation therapy [International Normalized Ratio (INR) 2.0-3.0]. 19 pts. with (1) newly diagnosed AF and no evidence of atrial thrombi and (2) an equivalent anticoagulation regimen served as the control group. In both groups (a) MRI/DWI studies of the brain (weeks 0, 4, 8, 12, 20, 28, 36, 44, and 52), (b) transesophageal echocardiographic studies (TEE) for assessment of LA-Thrombi (weeks 0 and 52) and (c) clinical neurological assessments (weeks 0, 20 and 52) were performed. Results: In the study group (AF and LA-Thrombi) 11 out of 32 pts. (34%) displayed signs of acute (n=8) or chronic (n=3) cerebral embolism in the initial MRI studies. In 4 out of 32 pts.(13%), MRI/DWI depicted new or additional cerebral emboli (n=12) during the follow-up period despite continuous anticoagulation therapy. 2 (n=2/4; 50%) of these patients had clinically apparent neurological deficits. In the control group 1 out of 19 pts

  18. Increased atrial natriuretic factor receptor density in cultured vascular smooth muscle cells of the spontaneously hypertensive rat

    International Nuclear Information System (INIS)

    Khalil, F.; Fine, B.; Kuriyama, S.; Hatori, N.; Nakamura, A.; Nakamura, M.; Aviv, A.

    1987-01-01

    To explore the role of the atrial natriuretic factor (ANF) system in the pathophysiology of hypertension we examined the binding kinetics of synthetic ANF to cultured vascular smooth muscle cells (VSMCs) derived from the spontaneously hypertensive rat (SHR) and two normotensive controls-the Wistar Kyoto (WKY) and American Wistar (W). The number of maximal binding sites (Bmax) per cell (mean +/- SEM; X10(3] were: SHR = 278.0 +/- 33.0, WKY = 28.3 +/- 7.1 and W = 26.6 +/- 4.2. The differences between the SHR and normotensive strains were significant at p less than 0.001. The equilibrium dissociation constant (Kd; X 10(-9)M) was higher in SHR VSMCs (0.94 +/- 0.14) than in WKY (0.22 +/- 0.09; p less than 0.01) and W (0.39 +/- 0.14; p less than 0.02) cells. The plasma levels of the immunoreactive ANF were higher in SHR than the normotensive controls. We suggest that the relatively greater ANF receptor density in cultured VSMCs of the SHR represents a response to the in vitro environment which is relatively more deficient in ANF for VSMCs of the SHR as compared with the normotensive rats. Thus, the capacity of the SHR VSMC to regulate ANF receptor density appears to be independent of the blood pressure level

  19. Evaluation of left ventricular function in patients with atrial fibrillation by ECG gated blood pool scintigraphy. Using frame count normalization method

    Energy Technology Data Exchange (ETDEWEB)

    Akanabe, Hiroshi; Oshima, Motoo; Sakuma, Sadayuki

    1988-07-01

    The assumption necessary to perform ECG gated blood pool scintigraphy (EGBPS) are seemingly not valid for patients with atrial fibrillation (af), since they have wide variability in cardiac cycle length. The data were acquired in frame mode within the limits of mean heart rate of fix the first diastolic volume, and were calculated by frame count normalization (FCN) method to correct total counts in each frame. EGBPS were performed twelve patients with af, who were operated against valvular disease. The data acquired within mean heart rate +-10 % in frame mode were divided to 32 frames, and calculated total frame counts. With FCN method total frame counts from at 22nd to 32nd frame were multiplied to be equal to the average of total frame counts. FCN method could correct total frame counts at the latter frames. And there was good correlation between left ventricular ejection fraction calculated from scintigraphy and that from contrast cineangiography. Thus EGBPS with FCN method may be allow estimation of cardiac function even in subjects with af.

  1. [Density of beta-adrenergic receptors and left ventricular mass in patients with primary essential hypertension].

    Science.gov (United States)

    Gajek, J; Zyśko, D; Spring, A

    2000-08-01

    Left ventricular hypertrophy (LVH) is one of the more important risk factors for sudden death. There are multiple factors for development of LVH in patients with hypertension. Sympathetic nervous system may play a key role causing afterload increase and neurohumoral mechanisms activation. The aim of the study was to determine beta-adrenergic receptors density and its relations to left ventricular mass in hypertensive subjects. The study was carried out in 63 patients (23 women and 40 men), mean age 43.3 +/- 11.6 yrs with primary hypertension: stage I--42 pts and stage II--21 pts. The control group consisted of 26 healthy persons matched for age and sex. We evaluated the density of beta-adrenergic receptors using 125I-cyanopindolol radioligand labeling method. Left ventricular dimensions were assessed by echocardiography (Hewlett-Packard 77010 CF) and left ventricular mass index (LVMI) was calculated. Systolic and diastolic blood pressure and LVMI was significantly higher in hypertension group 156.7 +/- 12.5 vs. 119.8 +/- 8.8 mmHg, p < 0.0001, 95.9/5.5 vs. 78.8 +/- 6.5 mmHg, p < 0.0001, 126.5 +/- 41.9 vs. 93.1 +/- 19.9 g/m2, p < 0.001 respectively. Beta-adrenergic receptors density was 40.7 +/- 29.9 fmol/ml in the hypertensive vs. 37.2 +/- 17.8 fmol/ml in control group (p = NS). There was no correlation between beta-adrenergic receptors density and LVMI. There was a statistically significant positive correlation between LVMI and systolic and diastolic blood pressure (r = 0.44, p < 0.05; r = 0.60, p < 0.01 respectively). 1. Beta-adrenergic receptors density was unchanged in patients with hypertension and did not correlate with LVMI. 2. A high positive correlation between blood pressure values and LVMI, but only in stage II hypertension was revealed.

  2. Adverse effects of permanent atrial fibrillation on heart failure in patients with preserved left ventricular function and chronic right apical pacing for complete heart block.

    Science.gov (United States)

    Lampe, Brigitte; Hammerstingl, Christoph; Schwab, Jörg Otto; Mellert, Fritz; Stoffel-Wagner, Birgit; Grigull, Andreas; Fimmers, Rolf; Maisch, Bernhard; Nickenig, Georg; Lewalter, Thorsten; Yang, Alexander

    2012-10-01

    The impact of atrial fibrillation (AF) on heart failure (HF) was evaluated in patients with preserved left ventricular (LV) function and long-term right ventricular (RV) pacing for complete heart block. Clinical, echocardiographic, and laboratory parameters of HF were assessed in 35 patients with established AF who had undergone ablation of the atrioventricular node and pacemaker implantation (Group A) and 31 patients who received dual-chamber pacing for spontaneous complete heart block (Group B). During a follow-up period of 12.7 ± 7.5 years, New York Heart Association (NYHA) functional class increased from 1.3 ± 0.5 to 2.1 ± 0.6 (p Left ventricular ejection fraction (LVEF) decreased from 59.7 ± 5.1 to 53.0 ± 8.2 (p function were moderately depressed in Group A compared with those in Group B: NYHA class 2.1 ± 0.6 versus 1.6 ± 0.7, p = 0.001; LVEF 53.0 ± 8.2 versus 56.9 ± 7.0 %, p brain natriuretic peptide (NT-proBNP) 1116.8 ± 883.9 versus 622.9 ± 1059.4 pg/ml, p 10 %, increasing NYHA class ≥1, and NT-proBNP levels >1,000 pg/ml. Permanent AF was associated with adverse effects on LV function and symptoms of HF in patients with long-term RV pacing for complete heart block, and appears to play an important role in the development of HF in this specific patient cohort.

  3. The incidence and prognostic significance of new-onset atrial fibrillation in patients with acute myocardial infarction and left ventricular systolic dysfunction: a CARISMA substudy

    DEFF Research Database (Denmark)

    Jons, Christian; Jacobsen, Uffe G; Joergensen, Rikke Moerch

    2011-01-01

    The incidence and risk associated with new-onset atrial fibrillation (AF) occurring after discharge in patients with acute myocardial infarction (MI) remains unknown.......The incidence and risk associated with new-onset atrial fibrillation (AF) occurring after discharge in patients with acute myocardial infarction (MI) remains unknown....

  4. Pharmacological Treatment for Atrial Fibrillation

    Directory of Open Access Journals (Sweden)

    Kaoru Sugi, MD PhD

    2005-01-01

    Full Text Available Pharmacological treatment for atrial fibrillation has a variety of purposes, such as pharmacological defibrillation, maintenance of sinus rhythm, heart rate control to prevent congestive heart failure and prevention of both cerebral infarction and atrial remodeling. Sodium channel blockers are superior to potassium channel blockers for atrial defibrillation, while both sodium and potassium channel blockers are effective in the maintenance of sinus rhythm. In general, digitalis or Ca antagonists are used to control heart rate during atrial fibrillation to prevent congestive heart failure, while amiodarone or bepridil also reduce heart rates during atrial fibrillation. Anticoagulant therapy with warfarin is recommended to prevent cerebral infarction and angiotensin converting enzyme antagonists or angiotensin II receptor blockers are also used to prevent atrial remodeling. One should select appropriate drugs for treatment of atrial fibrillation according to the patient's condition.

  5. Organized Atrial Tachycardias after Atrial Fibrillation Ablation

    Science.gov (United States)

    Castrejón-Castrejón, Sergio; Ortega, Marta; Pérez-Silva, Armando; Doiny, David; Estrada, Alejandro; Filgueiras, David; López-Sendón, José L.; Merino, José L.

    2011-01-01

    The efficacy of catheter-based ablation techniques to treat atrial fibrillation is limited not only by recurrences of this arrhythmia but also, and not less importantly, by new-onset organized atrial tachycardias. The incidence of such tachycardias depends on the type and duration of the baseline atrial fibrillation and specially on the ablation technique which was used during the index procedure. It has been repeatedly reported that the more extensive the left atrial surface ablated, the higher the incidence of organized atrial tachycardias. The exact origin of the pathologic substrate of these trachycardias is not fully understood and may result from the interaction between preexistent regions with abnormal electrical properties and the new ones resultant from radiofrequency delivery. From a clinical point of view these atrial tachycardias tend to remit after a variable time but in some cases are responsible for significant symptoms. A precise knowledge of the most frequent types of these arrhythmias, of their mechanisms and components is necessary for a thorough electrophysiologic characterization if a new ablation procedure is required. PMID:21941669

  6. Effect of exercise on circulating atrial natriuretic peptide and left ventricular ejection fraction in healthy persons and patients with coronary artery disease

    International Nuclear Information System (INIS)

    Nakamura, Tetsuya; Ichikawa, Shuichi; Sakamaki, Tetsuo; Suzuki, Tadashi; Iizuka, Toshio; Yagi, Atsuko; Kurashina, Toshiaki; Kumakura, Hisao; Murata, Kazuhiko

    1988-01-01

    Radionuclide angiographic measurements of left ventricular ejection fraction were performed at rest and during exercise in 10 normal persons and 11 patients with coronary artery disease. Exercise was continued on a supine bicycle exercise table up to a symptom-limited maximum. Plasma levels of atrial natriuretic peptide (ANP) were also determined at rest and during exercise. Ejection fraction in the normal volunteers was 59±3% (mean±SEM) at rest and increased significantly (p<0.01) to 69±3% during exercise. Ejection fraction in the patients was 47±5% at rest and did not change significantly during exercise (51±7%). Plasma ANP in the normals rose significantly (p<0.01) from 62±16 pg/ml at rest to 454±94 pg/ml during exercise. Plasma ANP in the patients also rose significantly (p<0.01) from 231±102 pg/ml to 794±170 pg/ml. The response of plasma ANP to exercise was enhanced significantly (p<0.05) in the patients as compared with the normals in relation to ejection fraction by analysis of covariance. In both the normals and the patients, plasma ANP was inversely and significantly correlated with ejection fraction during exercise (r=0.46, p<0.05, n=21), however, not at rest. Because it has been reported that plasma ANP is correlated positively with pulmonary artery wedge pressure, the estimation of plasma ANP during an exercise stress test might be used for the evaluation of cardiac reserve in coronary artery disease. (author)

  7. - LAA Occluder View for post-implantation Evaluation (LOVE) - standardized imaging proposal evaluating implanted left atrial appendage occlusion devices by cardiac computed tomography

    International Nuclear Information System (INIS)

    Behnes, Michael; Akin, Ibrahim; Sartorius, Benjamin; Fastner, Christian; El-Battrawy, Ibrahim; Borggrefe, Martin; Haubenreisser, Holger; Meyer, Mathias; Schoenberg, Stefan O.; Henzler, Thomas

    2016-01-01

    A standardized imaging proposal evaluating implanted left atrial appendage (LAA) occlusion devices by cardiac computed tomography angiography (cCTA) has never been investigated. cCTA datasets were acquired on a 3 rd generation dual-source CT system and reconstructed with a slice thickness of 0.5 mm. An interdisciplinary evaluation was performed by two interventional cardiologists and one radiologist on a 3D multi-planar workstation. A standardized multi-planar reconstruction algorithm was developed in order to assess relevant clinical aspects of implanted LAA occlusion devices being outlined within a pictorial essay. The following clinical aspects of implanted LAA occlusion devices were evaluated within the most appropriate cCTA multi-planar reconstruction: (1) topography to neighboring structures, (2) peri-device leaks, (3) coverage of LAA lobes, (4) indirect signs of neo-endothelialization. These are illustrated within concise CT imaging examples emphasizing the potential value of the proposed cCTA imaging algorithm: Starting from anatomical cCTA planes and stepwise angulation planes perpendicular to the base of the LAA devices generates an optimal LAA Occluder View for post-implantation Evaluation (LOVE). Aligned true axial, sagittal and coronal LOVE planes offer a standardized and detailed evaluation of LAA occlusion devices after percutaneous implantation. This pictorial essay presents a standardized imaging proposal by cCTA using multi-planar reconstructions that enables systematical follow-up and comparison of patients after LAA occlusion device implantation. The online version of this article (doi:10.1186/s12880-016-0127-y) contains supplementary material, which is available to authorized users

  8. Study of correlation between polymorphism of angiotensin II-1 receptor gene A1166 genotype and complications in atrial fibrillation

    International Nuclear Information System (INIS)

    Wang Yueping; Gong Wuxing; Shi Li

    2010-01-01

    Objective: To investigate the effect of genetic polymorphism on atrial fibrillation. Methods: Polymerase chain reaction-restrictive fragment length polymorphism(PCR-RFLP) was used to identify and compare the genotype of the location of AT1R gene 1166, and color echo-ultrasound was performed with logistic regression used to analyse the independent risk of various genotypes for atrial fibrillation in 121 patients with atrial fibrillation and 100 controls. Results: (1) Frequency of genotype AC + CC, iso-gene C in atrial fibrillation group was higher than that in control group (P=0.017, 0.013), the risk ratio in patients with genotype AC + CC to develop atrial fibrillation was 3.657 compared with genotype AA (95% CI:1.181∼11.322), and genotype difference as well as systolic pressure were involved in occurrence of overall atrial fibrillation. The OR to develop atrial fibrillation in patients with genotype AC + CC was 4.132 compared with genotype AA (95% CI:1.263∼13.513). (2) There were no significant differences of clinical manifestation (heart failure, cerebral embolism) or ultrasonic parameters among patients with different genotypes (AA vs AC + CC)(P>0.05). Conclusion: People carrying iso-gene C in AT1R gene 1166 were more liable to develop atrial fibrillation, but there were no correlationship with development of complications. (authors)

  9. Interaction of cadmium with atrial natriuretic factor receptors: Ligand binding and cellular processing

    International Nuclear Information System (INIS)

    Giridhar, J.; Rathinavelu, A.; Isom, G.E.

    1990-01-01

    ANF is a peptide hormone secreted by the heart and produces potent diuresis and vascular smooth muscle relaxation. It is well known that Cd produces cardiovascular toxicity and is implicated in the pathogenesis of hypertension. Hence the effects of Cd on ANF receptor dynamics and ligand binding were studied in PC12 cells. Receptor internalization using 125 I-ANF as the ligand at 37 degree C displayed a decrease in endocytic rate constants (ERC) when either preincubated with Cd (500 μM for 30 min, ERC = 0.183/min) or coincubated with Cd (500 μM, ERC = 0.196) when compared to control value (ERC = 0.259/min). Ligand binding ( 125 I-ANF) was changed by Cd as reflected by a decrease in the number of binding sites/cell in both Cd preincubated (Kd = 3.81 x 10 -10 M, B max = 1 x 10 -10 M, binding sites/cell = 9333) and coincubated cells (Kd = 1.76 x 10 -10 M, B max = 3.92 x 10 -11 M, binding sites/cell = 5960) from control (Kd = 3.87 x 10 -10 M, B max = 9.58 x 10 -11 M, binding sites/cell = 12141). Photoaffinity labelling with 125 I-ANF as the ligand was used to measure receptor subtype binding. Coincubation of cells with Cd (500 μM) and ligand decreased both high and low mol. wt. receptor binding, whereas preincubation with Cd (500μM) for 60 min produced a slight decrease in binding of both receptor subtypes. These results indicate that the cardiovascular toxicity of Cd may be partially mediated by altered ANF receptor function

  10. Comparative efficacy of amiodarone with ivabradin combination or amiodarone with bisoprolol combination in the prevention of atrial fibrillation recurrence in pa- tients with left ventricular diastolic dysfunction

    Directory of Open Access Journals (Sweden)

    K. G. Adamyan

    2015-01-01

    Full Text Available Aim. To study the efficacy of use of amiodarone with ivabradine combination or amiodarone with bisoprolol combination in the prevention of atrial fibrillation (AF recurrence in patients (pts with left ventricular diastolic dysfunction (LVDD after conversion to sinus rhythm. Material and methods. 65 patients (40 males, 25 females aged 53±8 years with persistent AF and LVDD were included into the study and randomized into 3 groups to receive ivabradine and amiodarone (22 pts, bisoprolol and amiodarone (22 pts or amiodarone alone (21 pts. Left atrium (LA volume indices, LA longitudinal strain rate (LASR in systole, LV mass index, mean heart rate (HR, 24-hour HR variability and the incidence of AF by 96 h ECG monitoring were measured after the titration period, and after 3 and 6 months of follow-up. Results. After 6 months of follow-up group 1 revealed significantly lower maximum LA volume index (21.3±2.4 vs 25.2±3.0 and 28.7±3.6 ml/m2 in the 2nd and control groups, respectively, P-wave LA volume index (15.3±3.5 versus 18.1±3.8 and 20.4±4.0 ml/m2 in the 2nd and control groups, respectively, and LA systolic volume index (7.3±1.2 versus 9.4±1.6 and 9.6±1.7 ml/m2 in 2nd and control groups, respectively. The incidence of side effects in group 1 was significantly less than that in group 2 and was not different compared with control group. Conclusion. Ivabradine and amiodarone combination provides better prevention of AF recurrence and less side-effects in pts with LVDD and persistent AF after sinus rhythm restoration as compared with bisoprolol and amiodarone combination, it also reduces LA maximum, conduit and systolic volumes, and increases LASR.

  11. Impaired atrial electromechanical function and atrial fibrillation promotion in alloxan-induced diabetic rabbits.

    Science.gov (United States)

    Fu, Huaying; Liu, Changle; Li, Jian; Zhou, Changyu; Cheng, Lijun; Liu, Tong; Li, Guangping

    2013-01-01

    Diabetes mellitus (DM) is an independent risk factor for atrial fibrillation (AF). However, the underlying mechanisms are still not clearly elucidated. The aim of this study was to evaluate the atrial electromechanical function, atrial electrophysiological changes and AF inducibility in alloxan-induced diabetic rabbits. In 8 alloxan-induced diabetic rabbits and 8 controls, we evaluated atrial electromechanical function by tissue Doppler imaging. Isolated Langendorff-perfused rabbit hearts were prepared to measure atrial refractory effective period (AERP) and its dispersion (AERPD), interatrial conduction time (IACT) and vulnerability to AF. Atrial interstitial fibrosis was evaluated by Sirius-Red staining. Compared with controls, left atrial lateral wall Pa'-start interval (Pastart) and right atrial wall Pastart were increased in diabetic rabbits. AERPD was increased and IACT was prolonged in diabetic rabbits. Inducibility of AF in diabetic group was significant higher than controls (6/8 vs. 1/8, p TEMA); left atrial lateral wall Papeak and TEMA, left atrial posterior wall TEMA, and IACT were correlated with atrial areas of fibrosis. Atrial electromechanical function is impaired in diabetic rabbits, and is associated with atrial fibrosis and interatrial electrical conduction delay.

  12. Atrial natriuretic peptide (ANP)-granules: ultrastructure ...

    African Journals Online (AJOL)

    AJB SERVER

    2006-12-29

    Dec 29, 2006 ... morphometry and function. Eliane Florencio ... granules is greatest in the right atrium followed by the left atrium and left auricle and right auricle, in this order. ... family: Atrial natriuretic peptide (ANP), Urodilatin, Brain natriuretic ...

  13. Effects of Prolonged Spaceflight on Atrial Size, Atrial Electrophysiology, and Risk of Atrial Fibrillation.

    Science.gov (United States)

    Khine, Htet W; Steding-Ehrenborg, Katarina; Hastings, Jeffrey L; Kowal, Jamie; Daniels, James D; Page, Richard L; Goldberger, Jeffery J; Ng, Jason; Adams-Huet, Beverley; Bungo, Michael W; Levine, Benjamin D

    2018-05-01

    The prevalence of atrial fibrillation (AF) in active astronauts is ≈5%, similar to the general population but at a younger age. Risk factors for AF include left atrial enlargement, increased number of premature atrial complexes, and certain parameters on signal-averaged electrocardiography, such as P-wave duration, root mean square voltage for the terminal 20 ms of the signal-averaged P wave, and P-wave amplitude. We aimed to evaluate changes in atrial structure, supraventricular beats, and atrial electrophysiology to determine whether spaceflight could increase the risk of AF. Thirteen astronauts underwent cardiac magnetic resonance imaging to assess atrial structure and function before and after 6 months in space and high-resolution Holter monitoring for multiple 48-hour time periods before flight, during flight, and on landing day. Left atrial volume transiently increased after 6 months in space (12±18 mL; P =0.03) without changing atrial function. Right atrial size remained unchanged. No changes in supraventricular beats were noted. One astronaut had a large increase in supraventricular ectopic beats but none developed AF. Filtered P-wave duration did not change over time, but root mean square voltage for the terminal 20 ms decreased on all fight days except landing day. No changes in P-wave amplitude were seen in leads II or V 1 except landing day for lead V 1 . Six months of spaceflight may be sufficient to cause transient changes in left atrial structure and atrial electrophysiology that increase the risk of AF. However, there was no definite evidence of increased supraventricular arrhythmias and no identified episodes of AF. © 2018 American Heart Association, Inc.

  14. Size and receptor density of glutamatergic synapses: a viewpoint from left-right asymmetry of CA3-CA1 connections

    Directory of Open Access Journals (Sweden)

    Yoshiaki Shinohara

    2009-07-01

    Full Text Available Synaptic plasticity is considered to be the main mechanism for learning and memory. Excitatory synapses in the cerebral cortex and hippocampus undergo plastic changes during development and in response to electric stimulation. It is widely accepted that this process is mediated by insertion and elimination of various glutamate receptors. In a series of recent investigations on left-right asymmetry of hippocampal CA3-CA1 synapses, glutamate receptor subunits have been found to have distinctive expression patterns that depend on the postsynaptic density (PSD area. Particularly notable are the GluR1 AMPA receptor subunit and NR2B NMDA receptor subunit, where receptor density has either a supra-linear (GluR1 AMPA or inverse (NR2B NMDAR relationship to the PSD area. We review current understanding of structural and physiological synaptic plasticity and propose a scheme to classify receptor subtypes by their expression pattern with respect to PSD area.

  15. CT based 3D printing is superior to transesophageal echocardiography for pre-procedure planning in left atrial appendage device closure.

    Science.gov (United States)

    Obasare, Edinrin; Mainigi, Sumeet K; Morris, D Lynn; Slipczuk, Leandro; Goykhman, Igor; Friend, Evan; Ziccardi, Mary Rodriguez; Pressman, Gregg S

    2018-05-01

    Accurate assessment of the left atrial appendage (LAA) is important for pre-procedure planning when utilizing device closure for stroke reduction. Sizing is traditionally done with transesophageal echocardiography (TEE) but this is not always precise. Three-dimensional (3D) printing of the LAA may be more accurate. 24 patients underwent Watchman device (WD) implantation (71 ± 11 years, 42% female). All had complete 2-dimensional TEE. Fourteen also had cardiac computed tomography (CCT) with 3D printing to produce a latex model of the LAA for pre-procedure planning. Device implantation was unsuccessful in 2 cases (one with and one without a 3D model). The model correlated perfectly with implanted device size (R 2  = 1; p < 0.001), while TEE-predicted size showed inferior correlation (R 2  = 0.34; 95% CI 0.23-0.98, p = 0.03). Fisher's exact test showed the model better predicted final WD size than TEE (100 vs. 60%, p = 0.02). Use of the model was associated with reduced procedure time (70 ± 20 vs. 107 ± 53 min, p = 0.03), anesthesia time (134 ± 31 vs. 182 ± 61 min, p = 0.03), and fluoroscopy time (11 ± 4 vs. 20 ± 13 min, p = 0.02). Absence of peri-device leak was also more likely when the model was used (92 vs. 56%, p = 0.04). There were trends towards reduced trans-septal puncture to catheter removal time (50 ± 20 vs. 73 ± 36 min, p = 0.07), number of device deployments (1.3 ± 0.5 vs. 2.0 ± 1.2, p = 0.08), and number of devices used (1.3 ± 0.5 vs. 1.9 ± 0.9, p = 0.07). Patient specific models of the LAA improve precision in closure device sizing. Use of the printed model allowed rapid and intuitive location of the best landing zone for the device.

  16. Vasorelaxant potencies and receptor binding affinities of atrial natriuretic hormone (ANH) analogues

    International Nuclear Information System (INIS)

    Bush, E.N.; Green, E.M.; Artman, L.D.; Devine, E.M.; Sarin, V.; Rockway, T.W.; Connolly, P.J.; Kiso, Y.; Holleman, W.H.

    1986-01-01

    ANH (1-28) (α-rat ANP) produces hypotensive effects in vivo, presumably via interaction with specific receptors. Vasorelaxant potencies (pD 2 ) and intrinsic activities of ANH analogues were measured in histamine constricted rabbit aorta rings. Binding affinities (K/sub I/) of the compounds were studied in rabbit aorta renal cortex and adrenal, using the radio-ligand 125 I-Tyr 28 -ANH (1-28). Significant correlations (r 2 s in aorta, and the log D/sub I/s in each of the three tissues were observed for the following cyclic compounds, listed in order of potency: ANH (1-28) greater than or equal to ANH (6-28) greater than or equal to Met 12 -ANH (1-28) (α-human ANP) greater than or equal to cyclohexyl-Ala (Cha) 8 -ANH (5-28) > Lys 11 -ANH (5-28) = ANH (5-28) (atriopeptin III) = ANH (5-27) (atriopeptin II) = Cha 21 -ANH (5-28) greater than or equal to ANH (7-28) > Cha 15 -ANH (5-28) = Pro 10 -ANH (5-28) = ANH (5-25) (atriopeptin I) = Asn 13 -ANH (5-28) = Tyr 9 -ANH (5-28) > des-Gly 9 -ANH (5-28) > ANH (7-23) = Pro 10 -ANH (7-23) greater than or equal to (D)Ala 9 -ANH (7-23) > Pro 9 -ANH (7-13). In summary, the affinities of several ANH analogues for both vascular and nonvascular receptors agree with their vasorelaxant potencies

  17. Impact of alcohol habits and smoking on the risk of new-onset atrial fibrillation in hypertensive patients with ECG left ventricular hypertrophy

    DEFF Research Database (Denmark)

    Ariansen, Inger; Reims, Henrik M; Gjesdal, Knut

    2012-01-01

    The incidence of new-onset atrial fibrillation (AF) is increased by uncontrolled hypertension, and antihypertensive treatment reduces new-onset AF. However, it is unclear whether alcohol intake and smoking influence the risk of new-onset AF during antihypertensive treatment....

  18. Radionuclide assessment of left ventricular diastolic function in patients with mitral stenosis before and after percutaneous transvenous mitral commissurotomy; Use of list mode method in patients with atrial fibrillation

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Seishi; Iwasaka, Toshiji; Kimura, Yutaka; Ohkubo, Naohiko; Matsuura, Takashi; Inada, Mitsuo; Shiraishi, Tomokuni [Kansai Medical School, Moriguchi, Osaka (Japan)

    1991-07-01

    To evaluate the effect of percutaneous transvenous mitral commissurotomy (PTMC), equilibrium radionuclide angiocardiography was performed in eight patients with mitral stenosis who had atrial fibrillation. Accurate cardiac function in patients with atrial fibrillation is difficult to assess, since the wide fluctation of cardiac cycle makes the ventricular hemodynamics variable. A new processing algorhythm was devised to make multiple gated images discriminated from a heart rate distribution histogram. We obtained about 1,000 beats data by list mode acquisition, and processed a heart rate distribution histogram. The data in the area {+-}5% of the most frequent heart rate were converted into frame mode and a representative time activity curve was derived. Mitral valve area calculated by echocardiography increased from 1.3{+-}0.5 to 2.0{+-}0.6 (cm{sup 2}) significantly (p<0.01). The mean transmitral pressure gradient measured by catheterization decreased from 12.4{+-}5.9 to 4.9{+-}3.7 (mmHg) significantly (p<0.01) and the clinical symptoms improved in all patients. The change in left ventricular ejection fraction from 43{+-}9 to 48{+-}13 (%) was not statistically significant, but peak filling rate (PFR) derived from the time activity curve increased from 1.5{+-}0.3 to 2.0{+-}0.4 (EDV/sec) significantly (p<0.01). Thus PFR is a noninvasive parameter that can evaluate the effect of PTMC. (author).

  19. Three-dimensional rotational angiography of the left atrium and the oesophagus: the short-term mobility of the oesophagus and the stability of the fused three-dimensional model of the left atrium and the oesophagus during catheter ablation for atrial fibrillation.

    Science.gov (United States)

    Starek, Zdenek; Lehar, Frantisek; Jez, Jiri; Scurek, Martin; Wolf, Jiri; Kulik, Tomas; Zbankova, Alena; Novak, Miroslav

    2017-08-01

    The objective of this study was to evaluate the mobility of the oesophagus and the stability of the three-dimensional (3D) model of the oesophagus using 3D rotational angiography (3DRA) of the left atrium (LA) and the oesophagus, fused with live fluoroscopy during catheter ablation for atrial fibrillation. From March 2015 to September 2015, 3DRA of the LA and the oesophagus was performed in 33 patients before catheter ablation for atrial fibrillation. Control contrast oesophagography was performed every 30 min. The positions of the oesophagograms and the 3D model of the LA and the oesophagus were repeatedly measured and compared with the spine. The average shift of the oesophagus ranged from 2.7 ± 2.2 to 5.0 ± 3.5 mm. The average real-time oesophageal shift ranged from 2.7 ± 2.2 to 3.8 ± 3.4 mm. No significant shift was detected until the 90th minute of the procedure. The average shift of the 3D model of the LA and the oesophagus ranged from 1.4 ± 1.8 to 3.3 ± 3.0 mm (right-left direction) and from 0.9 ± 1.2 to 2.2 ± 1.3 mm (craniocaudal direction). During the 2 h procedure, there were no significant shifts of the model. During catheter ablation for atrial fibrillation, there is no significant change in the position of the oesophagus until the 90th minute of the procedure and no significant shift in the 3D model of the LA and the oesophagus. The 3D model of the oesophagus reliably depicts the position of the oesophagus during the entire procedure. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  20. Influence of heart rhythm, breathing and arm position during computed tomography scanning on the registration accuracy of electro anatomical map (EAM) images, left atrium three-dimensional computed tomography angiography images, and fluoroscopy time during ablation to treat atrial fibrillation

    International Nuclear Information System (INIS)

    Chono, Taiki; Shimoshige, Shinya; Yoshikawa, Kenta; Mizonobe, Kazuhusa; Ogura, Keishi

    2013-01-01

    In CARTOMERGE for treatment of atrial fibrillation (AF) by ablation, by integrating electro anatomical map (EAM) and left atrium three-dimensional computed tomography angiography (3D-CTA) images, identification of the ablation points is simplified and the procedure can be made carried out more rapidly. However, the influence that heart rhythm, breathing and arm position during CT scanning have on registration accuracy and fluoroscopy time is not clear. To clarify the influence on registration accuracy and fluoroscopy time of heart rhythm, breathing and arm position during CT scanning. The patients were CT-scanned during both sinus rhythm (SR) and AF in each study subject. We evaluated the registration accuracy of images reconstructed between the cardiac cycle and assessed the registration accuracy and fluoroscopy time of images obtained during inspiratory breath-hold, expiratory breath-hold and up and down position of the arm. Although the registration accuracy of the EAM image and left atrium 3D-CTA image showed a significant difference during SR, no significant difference was seen during AF. Expiratory breath-hold and down position of the arm resulted in the highest registration accuracy and the shortest fluoroscopy time. However, arm position had no significant effect on registration accuracy. Heart rhythm and breathing during CT scanning have a significant effect on the registration accuracy of EAM images, left atrium 3D-CTA images, and fluoroscopy time. (author)

  1. Norepinephrine-Induced Adrenergic Activation Strikingly Increased the Atrial Fibrillation Duration through β1- and α1-Adrenergic Receptor-Mediated Signaling in Mice.

    Directory of Open Access Journals (Sweden)

    Kenji Suita

    Full Text Available Atrial fibrillation (AF is the most common arrhythmias among old people. It causes serious long-term health problems affecting the quality of life. It has been suggested that the autonomic nervous system is involved in the onset and maintenance of AF in human. However, investigation of its pathogenesis and potential treatment has been hampered by the lack of suitable AF models in experimental animals.Our aim was to establish a long-lasting AF model in mice. We also investigated the role of adrenergic receptor (AR subtypes, which may be involved in the onset and duration of AF.Trans-esophageal atrial burst pacing in mice could induce AF, as previously shown, but with only a short duration (29.0 ± 8.1 sec. We found that adrenergic activation by intraperitoneal norepinephrine (NE injection strikingly increased the AF duration. It increased the duration to more than 10 minutes, i.e., by more than 20-fold (656.2 ± 104.8 sec; P<0.001. In this model, a prior injection of a specific β1-AR blocker metoprolol and an α1-AR blocker prazosin both significantly attenuated NE-induced elongation of AF. To further explore the mechanisms underlying these receptors' effects on AF, we assessed the SR Ca(2+ leak, a major trigger of AF, and consequent spontaneous SR Ca(2+ release (SCR in atrial myocytes. Consistent with the results of our in-vivo experiments, both metoprolol and prazosin significantly inhibited the NE-induced SR Ca(2+ leak and SCR. These findings suggest that both β1-AR and α1-AR may play important roles in the development of AF.We have established a long-lasting AF model in mice induced by adrenergic activation, which will be valuable in future AF study using experimental animals, such as transgenic mice. We also revealed the important role of β1- and α1-AR-mediated signaling in the development of AF through in-vivo and in-vitro experiments.

  2. Atrial Fibrillation

    DEFF Research Database (Denmark)

    Staerk, Laila; Sherer, Jason A; Ko, Darae

    2017-01-01

    The past 3 decades have been characterized by an exponential growth in knowledge and advances in the clinical treatment of atrial fibrillation (AF). It is now known that AF genesis requires a vulnerable atrial substrate and that the formation and composition of this substrate may vary depending...... on comorbid conditions, genetics, sex, and other factors. Population-based studies have identified numerous factors that modify the atrial substrate and increase AF susceptibility. To date, genetic studies have reported 17 independent signals for AF at 14 genomic regions. Studies have established...

  3. Evaluating the Atrial Myopathy Underlying Atrial Fibrillation: Identifying the Arrhythmogenic and Thrombogenic Substrate

    Science.gov (United States)

    Goldberger, Jeffrey J.; Arora, Rishi; Green, David; Greenland, Philip; Lee, Daniel C.; Lloyd-Jones, Donald M.; Markl, Michael; Ng, Jason; Shah, Sanjiv J.

    2015-01-01

    Atrial disease or myopathy forms the substrate for atrial fibrillation (AF) and underlies the potential for atrial thrombus formation and subsequent stroke. Current diagnostic approaches in patients with AF focus on identifying clinical predictors with evaluation of left atrial size by echocardiography serving as the sole measure specifically evaluating the atrium. Although the atrial substrate underlying AF is likely developing for years prior to the onset of AF, there is no current evaluation to identify the pre-clinical atrial myopathy. Atrial fibrosis is one component of the atrial substrate that has garnered recent attention based on newer MRI techniques that have been applied to visualize atrial fibrosis in humans with prognostic implications regarding success of treatment. Advanced ECG signal processing, echocardiographic techniques, and MRI imaging of fibrosis and flow provide up-to-date approaches to evaluate the atrial myopathy underlying AF. While thromboembolic risk is currently defined by clinical scores, their predictive value is mediocre. Evaluation of stasis via imaging and biomarkers associated with thrombogenesis may provide enhanced approaches to assess risk for stroke in patients with AF. Better delineation of the atrial myopathy that serves as the substrate for AF and thromboembolic complications might improve treatment outcomes. Furthermore, better delineation of the pathophysiologic mechanisms underlying the development of the atrial substrate for AF, particularly in its earlier stages, could help identify blood and imaging biomarkers that could be useful to assess risk for developing new onset AF and suggest specific pathways that could be targeted for prevention. PMID:26216085

  4. Atrial and ventricular function after cardioversion of atrial fibrillation.

    Science.gov (United States)

    Xiong, C.; Sonnhag, C.; Nylander, E.; Wranne, B.

    1995-01-01

    OBJECTIVE--Previous studies on atrial recovery after cardioversion of atrial fibrillation have not taken into account new knowledge about the pathophysiology of transmitral and transtricuspid flow velocity patterns. It is possible to shed further light on this problem if atrioventricular inflow velocity, venous filling pattern, and atrioventricular annulus motion are recorded and interpreted together. DESIGN--Prospective examinations of mitral and tricuspid transvalvar flow velocities, superior caval and pulmonary venous filling, and mitral and tricuspid annulus motion were recorded using Doppler echocardiography. Examinations were performed before and 24 hours, 1 month, and 20 months after cardioversion. SETTING--Tertiary referral centre for cardiac disease with facilities for invasive and non-invasive investigation. PATIENTS--16 patients undergoing cardioversion of atrial fibrillation in whom sinus rhythm had persisted for 24 hours or more. RESULTS--Before conversion there was no identifiable A wave in transvalvar flow recordings. The total motion of the tricuspid and mitral annulus was subnormal and there was no identifiable atrial component. Venous flow patterns in general showed a low systolic velocity. After conversion, A waves and atrial components were seen in all patients and increased significantly (P atrial components, an increased systolic component of venous inflow, an increased A wave velocity, and a decreased E/A ratio of the transvalvar velocity curves. The ventricular component of annulus motion was unchanged. Changes in general occurred earlier on the right side than the left. CONCLUSIONS--This study indicates that, in addition to the previously known electromechanical dissociation of atrial recovery that exists after cardioversion of atrial fibrillation, there may also be a transient deterioration of ventricular function modulating the transvalvar inflow velocity recordings. Function on the right side generally becomes normal earlier than on the

  5. Atrial Fibrillation: Diagnosis

    Science.gov (United States)

    ... of this page please turn JavaScript on. Feature: Atrial Fibrillation Atrial Fibrillation: Diagnosis Past Issues / Winter 2015 Table of Contents ... of your body's cells and organs. Read More "Atrial Fibrillation" Articles Atrial Fibrillation / Who Is at Risk for ...

  6. ATRIAL FLUTTER*

    African Journals Online (AJOL)

    1971-01-02

    Jan 2, 1971 ... Athero- sclerotic cardiovascular disease was present in 23 patients, of whom 3 had ... primum defect, atrial flutter was precipitated by cardiac catheterization. ..... Heart J., 70, 505. UNDERSTANDING REACTIVE DEPRESSION*

  7. Atrial fibrillation

    African Journals Online (AJOL)

    ABEOLUGBENGAS

    Mean blood pressures were 126.03± ... optimal. Keywords: Atrial fibrillation, thrombosis, CHADS2 Score, stroke risk, hypertensive heart disease, ... general population and the average age group ... Appendix 1) to stratify the stroke risk and we.

  8. Cardiac resynchronization therapy with His bundle pacing as a method of treatment of chronic heart failure in patients with permanent atrial fibrillation and left bundle branch block.

    Science.gov (United States)

    Boczar, Krzysztof; Sławuta, Agnieszka; Ząbek, Andrzej; Dębski, Maciej; Gajek, Jacek; Lelakowski, Jacek; Małecka, Barbara

    CRT is a therapeutic option for patients with heart failure, sinus rhythm, prolonged QRS complex duration and reduced ejection fraction. We present a case of 71-year-old woman with dilated cardiomyopathy, NYHA functional class III and AF. We implanted CRT combined with direct His-bundle pacing. The indication for such a therapy was a left bundle branch block with a QRS complex of 178ms and a left ventricular EF of 15%, left ventricular end-diastolic diameter (LVEDD) of 75mm. After 8months of follow-up the LVEDD was 60mm with EF 35-40%. Copyright © 2017. Published by Elsevier Inc.

  9. Defeito do anel fibroso mitral posterior com aneurisma de átrio esquerdo e insuficiência mitral: tratamento cirúrgico com sucesso Defect of the posterior mitral fibrous ring with left atrial aneurysm and mitral insufficiency: successful surgical treatment

    Directory of Open Access Journals (Sweden)

    Ronaldo Machado BUENO

    1999-10-01

    Full Text Available Aneurismas em átrio esquerdo são pouco comuns, podendo ocorrer na aurícula ou na parede do átrio esquerdo. Freqüentemente, são assintomáticos, podendo ocorrer arritmias, fenômenos tromboembólicos ou insuficiência cardíaca como complicação da sua evolução. Apresentamos paciente de 39 anos, do sexo feminino, com defeito do anel posterior da valva mitral levando a grande dilatação aneurismática da parede posterior do átrio esquerdo com insuficiência mitral. O diagnóstico foi feito pela radiografia de tórax (abaulamento de silhueta cardíaca esquerda e ecocardiograma (grande aneurisma do átrio esquerdo posteriormente à parede posterior do ventrículo esquerdo com insuficiência mitral. O estudo hemodinâmico sugeriu pseudo-aneurisma de ventrículo esquerdo. Submetida a tratamento cirúrgico com auxílio da circulação extracorpórea, realizou-se anuloplastia mitral e exclusão do aneurisma com reconstrução do assoalho do átrio esquerdo com retalho de pericárdio bovino. A paciente apresentou boa evolução pós-operatória, recebendo alta hospitalar no oitavo dia em boas condições clínicas.Atrial aneurysm is a rare condition and can be found on the atrial appendage or on the atrial wall. Most patients are asymptomatic, but arrhythmias, thromboembolism, and heart failure are common complications. We present a 39 years old female patient with posterior mitral ring defect causing a great aneurysm of the left posterior atrial wall with mitral insufficiency. The diagnosis was achieved by chest roentgenogram (marked prominence of the upper left heart border and echocardiography (great left atrial aneurysm behind the left posterior ventricular wall with mitral insufficiency. Left ventricular cineangiogram suggested the presence of a false aneurysm of the left ventricle. The patient subsequently underwent surgical treatment with cardiopulmonary bypass. Posterior mitral valve annuloplasty was performed with aneurysm exclusion

  10. Value of Combining Left Atrial Diameter and Amino-terminal Pro-brain Natriuretic Peptide to the CHA2DS2-VASc Score for Predicting Stroke and Death in Patients with Sick Sinus Syndrome after Pacemaker Implantation.

    Science.gov (United States)

    Mo, Bin-Feng; Lu, Qiu-Fen; Lu, Shang-Biao; Xie, Yu-Quan; Feng, Xiang-Fei; Li, Yi-Gang

    2017-08-20

    The CHA2DS2-VASc score is used clinically for stroke risk stratification in patients with atrial fibrillation (AF). We sought to investigate whether the CHA2DS2-VASc score predicts stroke and death in Chinese patients with sick sinus syndrome (SSS) after pacemaker implantation and to evaluate whether the predictive power of the CHA2DS2-VASc score could be improved by combining it with left atrial diameter (LAD) and amino-terminal pro-brain natriuretic peptide (NT-proBNP). A total of 481 consecutive patients with SSS who underwent pacemaker implantation from January 2004 to December 2014 in our department were included. The CHA2DS2-VASc scores were retrospectively calculated according to the hospital medical records before pacemaker implantation. The outcome data (stroke and death) were collected by pacemaker follow-up visits and telephonic follow-up until December 31, 2015. During 2151 person-years of follow-up, 46 patients (9.6%) suffered stroke and 52 (10.8%) died. The CHA2DS2-VASc score showed a significant association with the development of stroke (hazard ratio [HR] 1.45, 95% confidence interval [CI] 1.20-1.75, Ppacemaker implantation. The addition of LAD and NT-proBNP to the CHA2DS2-VASc score improved its predictive power for stroke and death, respectively, in this patient cohort. Future prospective studies are warranted to validate the benefit of adding LAD and NT-proBNP to the CHA2DS2-VASc score for predicting stroke and death risk in non-AF populations.

  11. Functional β2-adrenoceptors in rat left atria: effect of foot-shock stress.

    Science.gov (United States)

    Moura, André Luiz de; Hyslop, Stephen; Grassi-Kassisse, Dora M; Spadari, Regina C

    2017-09-01

    Altered sensitivity to the chronotropic effect of catecholamines and a reduction in the β 1 /β 2 -adrenoceptor ratio have previously been reported in right atria of stressed rats, human failing heart, and aging. In this report, we investigated whether left atrial inotropism was affected by foot-shock stress. Male rats were submitted to 3 foot-shock sessions and the left atrial inotropic response, adenylyl cyclase activity, and β-adrenoceptor expression were investigated. Left atria of stressed rats were supersensitive to isoprenaline when compared with control rats and this effect was abolished by ICI118,551, a selective β 2 -receptor antagonist. Schild plot slopes for the antagonism between CGP20712A (a selective β 1 -receptor antagonist) and isoprenaline differed from unity in atria of stressed but not control rats. Atrial sensitivity to norepinephrine, as well as basal and forskolin- or isoprenaline-stimulated adenylyl cyclase activities were not altered by stress. The effect of isoprenaline on adenylyl cyclase stimulation was partially blocked by ICI118,551 in atrial membranes of stressed rats. These findings indicate that foot-shock stress equally affects inotropism and chronotropism and that β 2 -adrenoceptor upregulation contributes to the enhanced inotropic response to isoprenaline.

  12. Pitx2 expression defines a left cardiac lineage of cells: evidence for atrial and ventricular molecular isomerism in the iv/iv mice

    NARCIS (Netherlands)

    Campione, M.; Ros, M. A.; Icardo, J. M.; Piedra, E.; Christoffels, V. M.; Schweickert, A.; Blum, M.; Franco, D.; Moorman, A. F.

    2001-01-01

    The homeobox gene Pitx2 has been characterized as a mediator of left-right signaling in heart, gut, and lung morphogenesis. However, the relationship between the developmental role of Pitx2 and its expression pattern at the organ level has not been explored. In this study we focus on the role of

  13. Role of atrial endothelial cells in the development of atrial fibrosis and fibrillation in response to pressure overload.

    Science.gov (United States)

    Kume, Osamu; Teshima, Yasushi; Abe, Ichitaro; Ikebe, Yuki; Oniki, Takahiro; Kondo, Hidekazu; Saito, Shotaro; Fukui, Akira; Yufu, Kunio; Miura, Masahiro; Shimada, Tatsuo; Takahashi, Naohiko

    Monocyte chemoattractant protein-1 (MCP-1)-mediated inflammatory mechanisms have been shown to play a crucial role in atrial fibrosis induced by pressure overload. In the present study, we investigated whether left atrial endothelial cells would quickly respond structurally and functionally to pressure overload to trigger atrial fibrosis and fibrillation. Six-week-old male Sprague-Dawley rats underwent suprarenal abdominal aortic constriction (AAC) or a sham operation. By day 3 after surgery, macrophages were observed to infiltrate into the endocardium. The expression of MCP-1 and E-selectin in atrial endothelium and the expression of intercellular adhesion molecule-1, vascular cell adhesion molecule-1, and ED1 in left atrial tissue were enhanced. Atrial endothelial cells were irregularly hypertrophied with the disarrangement of lines of cells by scanning electron microscopy. Various-sized gap formations appeared along the border in atrial endothelial cells, and several macrophages were located just in the endothelial gap. Along with the development of heterogeneous interstitial fibrosis, interatrial conduction time was prolonged and the inducibility of atrial fibrillation by programmed extrastimuli was increased in the AAC rats compared to the sham-operated rats. Atrial endothelium responds rapidly to pressure overload by expressing adhesion molecules and MCP-1, which induce macrophage infiltration into the atrial tissues. These processes could be an initial step in the development of atrial remodeling for atrial fibrillation. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Alpha1A-adrenergic receptor-directed autoimmunity induces left ventricular damage and diastolic dysfunction in rats.

    Directory of Open Access Journals (Sweden)

    Katrin Wenzel

    Full Text Available BACKGROUND: Agonistic autoantibodies to the alpha(1-adrenergic receptor occur in nearly half of patients with refractory hypertension; however, their relevance is uncertain. METHODS/PRINCIPAL FINDINGS: We immunized Lewis rats with the second extracellular-loop peptides of the human alpha(1A-adrenergic receptor and maintained them for one year. Alpha(1A-adrenergic antibodies (alpha(1A-AR-AB were monitored with a neonatal cardiomyocyte contraction assay by ELISA, and by ERK1/2 phosphorylation in human alpha(1A-adrenergic receptor transfected Chinese hamster ovary cells. The rats were followed with radiotelemetric blood pressure measurements and echocardiography. At 12 months, the left ventricles of immunized rats had greater wall thickness than control rats. The fractional shortening and dp/dt(max demonstrated preserved systolic function. A decreased E/A ratio in immunized rats indicated a diastolic dysfunction. Invasive hemodynamics revealed increased left ventricular end-diastolic pressures and decreased dp/dt(min. Mean diameter of cardiomyocytes showed hypertrophy in immunized rats. Long-term blood pressure values and heart rates were not different. Genes encoding sarcomeric proteins, collagens, extracellular matrix proteins, calcium regulating proteins, and proteins of energy metabolism in immunized rat hearts were upregulated, compared to controls. Furthermore, fibrosis was present in immunized hearts, but not in control hearts. A subset of immunized and control rats was infused with angiotensin (Ang II. The stressor raised blood pressure to a greater degree and led to more cardiac fibrosis in immunized, than in control rats. CONCLUSIONS/SIGNIFICANCE: We show that alpha(1A-AR-AB cause diastolic dysfunction independent of hypertension, and can increase the sensitivity to Ang II. We suggest that alpha(1A-AR-AB could contribute to cardiovascular endorgan damage.

  15. Characterization of the adenosine receptor in cultured embryonic chick atrial myocytes: Coupling to modulation of contractility and adenylate cyclase activity and identification by direct radioligand binding

    International Nuclear Information System (INIS)

    Liang, B.T.

    1989-01-01

    Adenosine receptors in a spontaneously contracting atrial myocyte culture from 14-day chick embryos were characterized by radioligand binding studies and by examining the involvement of G-protein in coupling these receptors to a high-affinity state and to the adenylate cyclase and the myocyte contractility. Binding of the antagonist radioligand [3H]-8-cyclopentyl-1,3-diproylxanthine ([3H]CPX) was rapid, reversible and saturable and was to a homogeneous population of sites with a Kd value of 2.1 +/- 0.2 nM and an apparent maximum binding of 26.2 +/- 3 fmol/mg of protein (n = 10, +/- S.E.). Guanyl-5-yl-(beta, gamma-imido)diphosphate had no effect on either the Kd or the maximum binding and CPX reversed the N6-R-phenyl-2-propyladenosine-induced inhibition of adenylate cyclase activity and contractility, indicating that [3H] CPX is an antagonist radioligand. Competition curves for [3H] CPX binding by a series of reference adenosine agonists were consistent with labeling of an A1 adenosine receptor and were better fit by a two-site model than by a one-site model. ADP-ribosylation of the G-protein by the endogenous NAD+ in the presence of pertussis toxin shifted the competition curves from bi to monophasic with Ki values similar to those of the KL observed in the absence of prior pertussis intoxication. The adenosine agonists were capable of inhibiting both the adenylate cyclase activity and myocyte contractility in either the absence or the presence of isoproterenol. The A1 adenosine receptor-selective antagonist CPX reversed these agonist effects. The order of ability of the reference adenosine receptor agonists in causing these inhibitory effects was similar to the order of potency of the same agonists in inhibiting the specific [3H]CPX binding (N6-R-phenyl-2-propyladenosine greater than N6-S-phenyl-2-propyladenosine or N-ethyladenosine-5'-uronic acid)

  16. Effect of piboserod, a 5-HT4 serotonin receptor antagonist, on left ventricular function in patients with symptomatic heart failure

    DEFF Research Database (Denmark)

    Kjekshus, John K; Torp-Pedersen, Christian; Gullestad, Lars

    2009-01-01

    weeks up titration. The primary endpoint was LVEF measured by cardiac magnetic resonance imaging (MRI). Secondary endpoints were LV volumes, N-terminal pro-brain natriuretic peptide, norepinephrine, quality of life, and 6 min walk test. Piboserod significantly increased LVEF by 1.7% vs. placebo (CI 0.......3, 3.2, P = 0.020), primarily through reduced end-systolic volume from 165 to 158 mL (P = 0.060). There was a trend for greater increase in LVEF (2.7%, CI -1.1, 6.6, P = 0.15) in a small subset of patients not on chronic beta-blocker therapy. There was no significant effect on neurohormones, quality......AIMS: Myocardial 5-HT(4) serotonin (5-HT) receptors are increased and activated in heart failure (HF). Blockade of 5-HT(4) receptors reduced left ventricular (LV) remodelling in HF rats. We evaluated the effect of piboserod, a potent, selective, 5-HT(4) serotonin receptor antagonist, on LV function...

  17. Importance of Pulmonary Vein Preferential Fibrosis for Atrial Fibrillation Promotion in Hypertensive Rat Hearts.

    Science.gov (United States)

    Iwasaki, Yu-Ki; Yamashita, Takeshi; Sekiguchi, Akiko; Hayami, Noriyuki; Shimizu, Wataru

    2016-06-01

    Hypertension is one of the independent risk factors for atrial fibrillation (AF). Pulmonary veins (PVs) play an important role as the substrate for AF and triggers of AF. The purpose of this study was to determine the structural remodelling of the PVs and its effect on promoting AF in hypertensive (HT) rat hearts. Eighteen-week-old Dahl salt-sensitive HT rats and their controls were used for histological and immunohistological analyses, and electrophysiological studies were performed in Langendorff perfused hearts. Masson-trichrome staining revealed that hypertension significantly increased the fibrosis in the PVs, particularly in subendocardial and perivascular areas, compared with that in control rats, however, at this early stage of hypertension, left atrial fibrosis was not prominent. In the HT rat hearts with PVs, electrical stimulation significantly increased the number of repetitive atrial firing and atrial tachycardia inducibility, which significantly diminished after the excision of the PVs. An immunofluorescent analysis revealed that HT rats had PV specific endocardial smooth muscle actin (αSMA)-positive cells with remarkable proliferation of platelet-derived growth factor (PDGF)-C and vascular endothelial growth factor (VEGF), which was lacking in the left atrial structures of the control and the HT rats. Pretreatment with imatinib, a PDGF receptor activity blocker, in HT rats reduced the αSMA-positive cell proliferation and fibrosis in the PVs and also induced a significant reduction in VEGF expression. Also, the drug pretreatment effectively prevented repetitive atrial firing promotion without affecting the blood pressure. PV preferential fibrosis might play an important role in the arrhythmogenic substrate of AF in HT rat hearts. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  18. Atrial fibrillation

    DEFF Research Database (Denmark)

    Olesen, Morten S; Nielsen, Morten W; Haunsø, Stig

    2014-01-01

    Atrial fibrillation (AF) is the most common cardiac arrhythmia affecting 1-2% of the general population. A number of studies have demonstrated that AF, and in particular lone AF, has a substantial genetic component. Monogenic mutations in lone and familial AF, although rare, have been recognized...

  19. [Atrial fibrillation].

    Science.gov (United States)

    Spinar, J; Vítovec, J

    2003-09-01

    Atrial fibrilation is the most frequent arrhythmia, the occurrence increasing with age and associated diseases. The incidence at the age below 60 years is markedly lower than one per cent, whereas in persons above 80 years of age it exceeds six per cent. The occurrence in patients with heart failure is from 10% (NYHA II) up to 50% (NYHA IV). Atrial fibrillation is classified into that observed for the first time and permanent, respectively, while transient forms include paroxyzmal and persistent atrial fibrillation. The diagnosis is based on ECG recording, while echocardiography is most significant. The therapy includes two basic questions--anticoagulant or anti-aggregation treatment and the control of rhythm or frequency. The anticoagulant therapy should be introduced in all patients, where contraindications are not present, being necessary before every cardioversion, provided atrial fibrillation lasts more than two days. In patients without any heart disease and with a physiological echocardiogram it is possible to administer only anti-aggregation treatment. Cardioversion (the control of rhythm) is recommended to all symptomatic patients, in other cases and especially in older persons the control of frequency is safer and of more advantage. Electrical cardioversion is more effective that a pharmacological treatment, the sinus rhythm is preferably controlled by dofetilid, ibutilid, propafenon and amiodaron. For the control of heart rate beta-blockers, diltiazem, verapamil and digitalis are recommended.

  20. Solubilization and molecular size of atrial natriuretic hormone (ANH) receptors from rabbit aorta, renal cortex and adrenal

    International Nuclear Information System (INIS)

    Budzik, G.P.; Bush, E.N.; Holleman, W.H.

    1986-01-01

    ANH(1-28) is presumed to regulate blood pressure and fluid balance via membrane receptors coupled to particulate guanylate cyclase. ANH receptors were solubilized from rabbit aorta, renal cortex and adrenal, primary ANH targets. Plasma membranes extracted with 3-[(3-cholamidopropyl)dimethylammonio]-1-propane sulfonate(CHAPS) yield solubilized receptors with high affinity binding of 125 I-Tyr 28 -ANH. Degradation of hormone was minimized with a broad spectrum of protease inhibitors. 125 I-ANH binding reached maximum by 1 hr at 0 0 C and was stable for at least an additional 2 hrs. Bound was separated from free ligand by HPLC gel filtration on TSK-3000SW in PBS/CHAPS. Bound hormone eluted at a MW of ∼ 200KD in each tissue preparation and was displaced by unlabelled ANH. The concentration of solubilized binding sites was proportional to densities in intact plasma membranes, i.e., adrenal > renal > aorta. Following separation of free hormone, 125 I-ANH-receptors complexes were coupled using bifunctional crosslinking reagents. SDS-PAGE analysis and autoradiography indicated a major labelled band at ∼ 150KD in each tissue preparation. The mobility of this labelled band was not sensitive to reduction before SDS-PAGE. Although these results suggest that solubilized ANH receptors from primary target tissues are very similar, microheterogeneity affecting binding affinity or signal transduction cannot as yet be excluded

  1. Pulmonary edema following transcatheter closure of atrial septal defect

    Directory of Open Access Journals (Sweden)

    Keerthi Chigurupati

    2015-01-01

    Full Text Available We describe an incident of development of acute pulmonary edema after the device closure of a secundum atrial septal defect in a 52-year-old lady, which was treated with inotropes, diuretics and artificial ventilation. Possibility of acute left ventricular dysfunction should be considered after the defect closure in the middle-aged patients as the left ventricular compliance may be reduced due to increased elastic stiffness and diastolic dysfunction. Baseline left atrial pressure may be > 10 mmHg in these patients. Associated risk factors for the left ventricular dysfunction are a large Qp:Qs ratio, systemic hypertension, severe pulmonary hypertension and paroxysmal atrial fibrillation.

  2. Migration of a Central Venous Catheter in a Hemodialysis Patient Resulted in Left Atrial Perforation and Thrombus Formation Requiring Open Heart Surgery.

    Science.gov (United States)

    Wong, Kevin; Marks, Barry A; Qureshi, Anwer; Stemm, Joseph J

    2016-07-01

    Central venous catheterization is widely used in patients on hemodialysis. A rare complication associated with the clinical use of central venous catheters is perforation of the heart or major vessels. We report a case of inadvertent perforation of the left atrium and thrombosis after the placement of a hemodialysis catheter in the right internal jugular vein. In such cases, surgical removal of the central venous catheter from perforation sites in the heart and vessel walls poses anesthetic challenges because of the high risk of pneumothorax, hemorrhage, arrhythmias, thrombosis, and death.

  3. Right heart function in impaired left ventricular diastolic function: 2D speckle tracking echocardiography-based and Doppler tissue imaging-based analysis of right atrial and ventricular function.

    Science.gov (United States)

    Brand, Anna; Bathe, Marny; Oertelt-Prigione, Sabine; Seeland, Ute; Rücke, Mirjam; Regitz-Zagrosek, Vera; Stangl, Karl; Knebel, Fabian; Stangl, Verena; Dreger, Henryk

    2018-01-01

    The aim of our study was to describe right atrial (RA) and right ventricular (RV) function, assessed by Doppler tissue imaging and 2D speckle tracking echocardiography (2DSTE), in women with signs of early impaired left ventricular diastolic function (DD). In a cross-sectional trial, standard parameters of diastolic and right heart function were investigated in 438 women of the Berlin Female Risk Evaluation (BEFRI) study. In a subset of women, average peak systolic RA strain (RAS), as well as the average peak systolic RV strain of the free wall (RVS free wall) and of all RV segments (average RV strain; RVS Avg), was analyzed using 2DSTE. Compared to women with normal diastolic function (DD0), RAS, RVS free wall and RVS Avg were significantly reduced in DD (43.1% ± 11.9%, -26.7% ± 5.6%, and -23.3% ± 3.5% in DD0; vs 35.1% ± 10.4%, -23.9% ± 5.5%, and -20.6% ± 3.8% in DD; P right heart function is significantly altered in DD. DTI as well as 2DSTE constitute sensitive echocardiographic tools that enable the diagnosis of impaired right heart mechanics in early-staged DD. © 2017 Wiley Periodicals, Inc.

  4. Inhibitory effects of psychotropic drugs on the acetylcholine receptor-operated potassium current (IK.ACh) in guinea-pig atrial myocytes.

    Science.gov (United States)

    Okada, Muneyoshi; Watanabe, Shinya; Matada, Takashi; Asao, Yoko; Hamatani, Ramu; Yamawaki, Hideyuki; Hara, Yukio

    2013-01-01

    Influences of psychotropic drugs, six antipsychotics and three antidepressants, on acetylcholine receptor-operated potassium current (IK.ACh) were examined by a whole-cell patch clamp method in freshly isolated guinea-pig atrial myocyte. IK.ACh was induced by a superfusion of carbachol (CCh) or by an intracellular application of guanosine 5'-[thio] triphosphate (GTPγS). To elucidate mechanism for anticholinergic action, IC50 ratio, the ratio of IC50 for GTPγS-activated IK.ACh to CCh-induced IK.ACh, was calculated. Antipsychotics and antidepressants inhibited CCh-induced IK.ACh in a concentration-dependent manner. The IC50 values were as follows; chlorpromazine 0.53 μM, clozapine 0.06 μM, fluphenazine 2.69 μM, haloperidol 2.66 μM, sulpiride 42.3 μM, thioridazine 0.07 μM, amitriptyline 0.03 μM, imipramine 0.22 μM and maprotiline 1.81 μM. The drugs, except for sulpiride, inhibited GTPγS-activated IK.ACh with following IC50 values; chlorpromazine 1.71 μM, clozapine 14.9 μM, fluphenazine 3.55 μM, haloperidol 2.73 μM, thioridazine 1.90 μM, amitriptyline 7.55 μM, imipramine 7.09 μM and maprotiline 5.93 μM. The IC50 ratio for fluphenazine and haloperidol was close to unity. The IC50 ratio for chlorpromazine, clozapine, thioridazine, amitriptyline, imipramine and maprotiline was much higher than unity. The present findings suggest that the psychotropics studied suppress IK.ACh. Chlorpromazine, clozapine, thioridazine, amitriptyline, imipramine, maprotiline and sulpiride are preferentially acting on muscarinic receptor. Fluphenazine and haloperidol may act on G protein and/or potassium channel.

  5. Relation of osteoprotegerin in severe aortic valve stenosis to postoperative outcome and left ventricular function

    DEFF Research Database (Denmark)

    Dahl, Jordi S; Videbæk, Lars; Poulsen, Mikael K

    2013-01-01

    Osteoprotegerin (OPG) is a member of the tumor necrosis factor receptor superfamily and is known to be among the mediators of the calcification process that has been shown to increase in patients with aortic stenosis (AS). The aim of this study was to characterize the association of OPG with left......, 41 patients died of a presumed cardiovascular cause or remained in New York Heart Association functional class III or IV. The risk of a poor postoperative outcome after AVR increased with increasing OPG tertiles (15% vs 33% vs 51%, p = 0.002). In a multivariate model containing age, ejection fraction......, N-terminal pro-brain natriuretic peptide and left atrial volume index, OPG was still significantly associated with postoperative outcome. In addition, OPG levels associated with cardiovascular mortality during follow-up. In conclusion, OPG is associated with LV and left atrial remodeling in patients...

  6. Atrial Fibrillation: Treatment

    Science.gov (United States)

    ... of this page please turn JavaScript on. Feature: Atrial Fibrillation Atrial Fibrillation: Treatment Past Issues / Winter 2015 Table of Contents Treatment for atrial fibrillation depends on how often you have symptoms, how ...

  7. 17β-Estradiol-induced interaction of estrogen receptor α and human atrial essential myosin light chain modulates cardiac contractile function.

    Science.gov (United States)

    Duft, Karolin; Schanz, Miriam; Pham, Hang; Abdelwahab, Ahmed; Schriever, Cindy; Kararigas, Georgios; Dworatzek, Elke; Davidson, Mercy M; Regitz-Zagrosek, Vera; Morano, Ingo; Mahmoodzadeh, Shokoufeh

    2017-01-01

    Chronic increased workload of the human heart causes ventricular hypertrophy, re-expression of the atrial essential myosin light chain (hALC-1), and improved contractile function. Although hALC-1 is an important positive inotropic regulator of the human heart, little is known about its regulation. Therefore, we investigated the role of the sex hormone 17β-estradiol (E2) on hALC-1 gene expression, the underlying molecular mechanisms, and the impact of this regulatory process on cardiac contractile function. We showed that E2 attenuated hALC-1 expression in human atrial tissues of both sexes and in human ventricular AC16 cells. E2 induced the nuclear translocation of estrogen receptor alpha (ERα) and hALC-1 in AC16 cells, where they cooperatively regulate the transcriptional activity of hALC-1 gene promoter. E2-activated ERα required the estrogen response element (ERE) motif within the hALC-1 gene promoter to reduce its transcriptional activity (vehicle: 15.55 ± 4.80 vs. E2: 6.51 ± 3.69; ~2 fold). This inhibitory effect was potentiated in the presence of hALC-1 (vehicle: 11.13 ± 3.66 vs. E2: 2.18 ± 1.10; ~5 fold), and thus, hALC-1 acts as a co-repressor of ERα-mediated transcription. Yeast two-hybrid screening of a human heart cDNA library revealed that ERα interacts physically with hALC-1 in the presence of E2. This interaction was confirmed by Co-Immunoprecipitation and immunofluorescence in human atrium. As a further novel effect, we showed that chronic E2-treatment of adult mouse cardiomyocytes overexpressing hALC-1 resulted in reduced cell-shortening amplitude and twitching kinetics of these cells independent of Ca 2+ activation levels. Together, our data showed that the expression of hALC-1 gene is, at least partly, regulated by E2/ERα, while hALC-1 acts as a co-repressor. The inotropic effect of hALC-1 overexpression in cardiomyocytes can be significantly repressed by E2.

  8. The role of Multidetector CT in the evaluation of the left atrium and pulmonary veins anatomy before and after radio-frequency catheter ablation for atrial fibrillation. Preliminary results and work in progress.Technical note; Il ruolo della TC Multidetettore nella valutazione anatomica dell'atrio sinistro e delle vene polmonari prima e dopo ablazione percutanea con radiofrequenza della fibrillazione atriale. Risultati preliminari e work in progress

    Energy Technology Data Exchange (ETDEWEB)

    Centoze, Maurizio; Della Sala, Sabino Walter; Dalla Palma, Francesco [Azienda Provinciale per i servizi sanitari, Trento (Italy). Dipartimento di radiodiagnostica; Del Greco, Maurizio; Marini, Massimiliano [Ospedale S. Chiara, Trento (Italy). U.O. di cardiologia; Nollo, Giandomenico; Ravelli, Flavia [Trento Univ., Trento (Italy). Dipartimento di fisica

    2005-07-15

    Radio-frequency catheter ablation (RFCA) of the distal pulmonary veins is increasingly being used to treat recurrent or refractory atrial fibrillation that doesn't respond to pharmacologic therapy or cardioversion. Successful RFCA of atrial al fibrillation depends on the pre-procedural understanding of the complex anatomy of the distal pulmonary veins and the left atrium. Aim of this parer is to describe the technical main features that characterise the multidetector helical computed tomography in the evaluation of this anatomic region before and after RFCA procedure. The 3D post-processing techniques useful for pre-RFCA planning are straightforward. [Italian] La ablazione percutanea con radiofrequenza (RFCA) del tratto distale delle vene polmonari nella fibrillazione atriale, che non risponde al trattamento farmacologico e alla cardioversione elettrica, e una procedura in grande sviluppo. Il successo del trattamento dipende dalla comprensione della complessa anatomia delle vene polmonari e dell'atrio sinistro. Lo scopo di questo articolo e illustrare gli aspetti tecnici fondamentali che caratterizzano lo studio di questa regione anatomica con TC spirale multidetettore prima e dopo RFCA. Particolare risalto e stato rivolto alle tecniche di post-processing 3D estremamente utili nella pianificazione della procedura di ablazione.

  9. No upregulation of digitalis glycoside receptor (Na,K-ATPase) concentration in human heart left ventricle samples obtained at necropsy after long term digitalisation.

    Science.gov (United States)

    Schmidt, T A; Holm-Nielsen, P; Kjeldsen, K

    1991-08-01

    The aim was to evaluate the hypothesis that digitalis glycosides increase the concentration of their specific receptor (Na,K-ATPase) in human myocardial tissue, thereby possibly reducing the inotropic effect of long term digitalis treatment. Intact samples of left ventricle were obtained at necropsy from patients who had been on long term treatment with digoxin and from patients not previously given digoxin. Digitalis glycoside receptors were quantified using vanadate facilitated 3H-ouabain binding before and after washing samples in buffer containing excess digoxin antibody fragments for 16 h at 30 degrees C. This washing procedure has previously been shown to reduce prior specific digoxin binding in human left ventricle by 95% and to allow subsequent vanadate facilitated complete quantification of 3H-ouabain binding sites. In this context it was performed to reduce occupancy of digitalis glycoside receptors by digoxin, caused by digitalisation before 3H-ouabain binding. 11 patients who had been on long term treatment with digoxin and eight who had not previously been given digoxin were studied. Left ventricle samples were obtained at necropsy at around 15 h after death. Standard 3H-ouabain binding was 39% less in samples from digitalised than from undigitalised subjects (p less than 0.001). Washing samples in buffer containing excess digoxin antibody fragments induced an increase in 3H-ouabain binding from 174(SEM 10) to 265(20) pmol.g-1 wet weight (n = 11, p less than 0.001) in samples from digitalised patients. After washing, the digitalis glycoside receptor concentration in left ventricle samples showed a tendency to a lower value (14%, p greater than 0.10) in patients exposed to digoxin compared to left ventricle samples from individuals unexposed to digitalis glycoside treatment. Calculating 3H-ouabain binding relative to dry ventricular muscle weight confirmed the results obtained using wet weight as reference. The results suggest that digoxin treatment in

  10. Noninvasive quantification of left-to-right shunt by phase contrast magnetic resonance imaging in secundum atrial septal defect: the effects of breath holding and comparison with invasive oximetry.

    Science.gov (United States)

    Yamasaki, Yuzo; Kawanami, Satoshi; Kamitani, Takeshi; Sagiyama, Koji; Sakamoto, Ichiro; Hiasa, Ken-Ichi; Yabuuchi, Hidetake; Nagao, Michinobu; Honda, Hiroshi

    2018-01-16

    To investigate the effect of breath-holding on left-to-right shunts in patients with a secundum atrial septal defect (ASD). Thirty-five consecutive patients with secundum ASDs underwent right heart catheterization and invasive oximetry. Phase-contrast magnetic resonance imaging (MRI) was performed for the main pulmonary artery and ascending aorta. All measurements were obtained during free breathing (FB) (quiet breathing; no breath-hold), expiratory breath-hold (EBH), and inspiratory breath-hold (IBH). Pulmonary circulation flow (Qp) and systemic circulation flow (Qs) were calculated by multiplying the heart rate by the stroke volume. Measurements during FB, EBH, and IBH were compared, and the differences compared to invasive oximetry were evaluated. There were significant differences among the measurements during FB, EBH, and IBH for Qp (FB, 7.70 ± 2.68; EBH, 7.18 ± 2.34; IBH, 6.88 ± 2.51 l/min); however, no significant difference was found for Qs (FB, 3.44 ± 0.74; EBH, 3.40 ± 0.83; IBH, 3.40 ± 0.86 l/min). There were significant differences among the measurements during FB, EBH, and IBH for Qp/Qs (FB, 2.38 ± 1.12; EBH, 2.24 ± 0.95; IBH, 2.14 ± 0.97). Qp/Qs during FB and EBH correlated better with Qp/Qs measured by invasive oximetry than did IBH. The limit of agreement was smaller for EBH than for FB and IBH. In patients with secundum ASDs, Qp/Qs significantly decreased with breath-holding. The accuracy of the Qp/Qs measurement by MRI compared with invasive oximetry during EBH was higher than during FB and IBH.

  11. Simplified single plane echocardiography is comparable to conventional biplane two-dimensional echocardiography in the evaluation of left atrial volume: a study validated by three-dimensional echocardiography in 143 individuals.

    Science.gov (United States)

    Vieira-Filho, Normando G; Mancuso, Frederico J N; Oliveira, Wercules A A; Gil, Manuel A; Fischer, Cláudio H; Moises, Valdir A; Campos, Orlando

    2014-03-01

    The left atrial volume index (LAVI) is a biomarker of diastolic dysfunction and a predictor of cardiovascular events. Three-dimensional echocardiography (3DE) is highly accurate for LAVI measurements but is not widely available. Furthermore, biplane two-dimensional echocardiography (B2DE) may occasionally not be feasible due to a suboptimal two-chamber apical view. Simplified single plane two-dimensional echocardiography (S2DE) could overcome these limitations. We aimed to compare the reliability of S2DE with other validated echocardiographic methods in the measurement of the LAVI. We examined 143 individuals (54 ± 13 years old; 112 with heart disease and 31 healthy volunteers; all with sinus rhythm, with a wide range of LAVI). The results for all the individuals were compared with B2DE-derived LAVIs and validated using 3DE. The LAVIs, as determined using S2DE (32.7 ± 13.1 mL/m(2)), B2DE (31.9 ± 12.7 mL/m(2)), and 3DE (33.1 ± 13.4 mL/m(2)), were not significantly different from each other (P = 0.85). The S2DE-derived LAVIs correlated significantly with those obtained using both B2DE (r = 0.98; P < 0.001) and 3DE (r = 0.93; P < 0.001). The mean difference between the S2DE and B2DE measurements was <1.0 mL/m(2). Using the American Society of Echocardiography criteria for grading LAVI enlargement (normal, mild, moderate, severe), we observed an excellent agreement between the S2DE- and B2DE-derived classifications (κ = 0.89; P < 0.001). S2DE is a simple, rapid, and reliable method for LAVI measurement that may expand the use of this important biomarker in routine echocardiographic practice. © 2013, Wiley Periodicals, Inc.

  12. Efficacy and safety of left atrial appendage closure with WATCHMAN in patients with or without contraindication to oral anticoagulation: 1-Year follow-up outcome data of the EWOLUTION trial.

    Science.gov (United States)

    Boersma, Lucas V; Ince, Hueseyin; Kische, Stephan; Pokushalov, Evgeny; Schmitz, Thomas; Schmidt, Boris; Gori, Tommaso; Meincke, Felix; Protopopov, Alexey Vladimir; Betts, Timothy; Foley, David; Sievert, Horst; Mazzone, Patrizio; De Potter, Tom; Vireca, Elisa; Stein, Kenneth; Bergmann, Martin W

    2017-09-01

    Left atrial appendage (LAA) occlusion with WATCHMAN has emerged as viable alternative to vitamin K antagonists in randomized controlled trials. EWOLUTION was designed to provide data in routine practice from a prospective multicenter registry. A total of 1025 patients scheduled for a WATCHMAN implant were prospectively and sequentially enrolled at 47 centers. Indication for LAA closure was based on European Society of Cardiology guidelines. Follow-up and transesophageal echocardiography (TEE) were performed per local practice. The baseline CHA 2 DS 2 -VASc score was 4.5 ± 1.6; the mean age was 73.4 ± 9 years; previous transient ischemic attack/ischemic stroke was present in 312 (30.5%), 155 (15.1%) had previous hemorrhagic stroke, and 320 (31.3%) had a history of major bleeding; and 750 (73%) were deemed unsuitable for oral anticoagulation therapy. WATCHMAN implant succeeded in 1005 (98.5%) of patients, without leaks >5 mm in 1002 (99.7%) with at least 1 TEE follow-up in 875 patients (87%). Antiplatelet therapy was used in 784 (83%), while vitamin K antagonists were used in only 75 (8%). At 1 year, mortality was 98 (9.8%), reflecting the advanced age and comorbidities in this population. Device thrombus was observed in 28 patients at routine TEE (3.7%) and was not correlated with the drug regimen (P = .14). Ischemic stroke rate was 1.1% (relative risk 84% vs estimated historical data); the major bleeding rate was 2.6% and was predominantly (2.3%) nonprocedure/device related. LAA closure with the WATCHMAN device has a high implant and sealing success. This method of stroke risk reduction appears to be safe and effective with an ischemic stroke rate as low as 1.1%, even though 73% of patients had a contraindication to and were not using oral anticoagulation. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  13. Atrial Septal Aneurysm Presenting as Clubbing without Clinically Apparent Cyanosis.

    Science.gov (United States)

    Goyal, Laxmi Kant; Banerjee, S; Yadav, R N; Singh, Gajraj; Ganguli, Sujata; Isran, Rohit

    2015-09-01

    Atrial septal aneurysm (ASA) is a localised "saccular" deformity which protrudes to the right or the left atrium or on both sides. It is a rare, but well recognised cardiac abnormality. It is usually an incidental finding or may presents as atrial arrhythmias or arterial embolism. Though it is an acyanotic congenital heart disease but it may result in significant right to left shunt and cyanosis. We describe a patient of ASA with atrial septal defect who presented with clubbing and right to left shunt without clinically apparent cyanosis. © Journal of the Association of Physicians of India 2011.

  14. The predictive value of transthoracic echocardiographic variables for sinus rhythm maintenance after electrical cardioversion of atrial fibrillation. Results from the CAPRAF study, a prospective, randomized, placebo-controlled study.

    Science.gov (United States)

    Grundvold, Irene; Tveit, Arnljot; Smith, Pål; Seljeflot, Ingebjørg; Abdelnoor, Michael; Arnesen, Harald

    2008-01-01

    The recurrence rate of atrial fibrillation after electrical cardioversion is disappointingly high. The aim of the present study was to prospectively investigate if standard echocardiographic variables at the day of cardioversion could predict sinus rhythm maintenance. Transthoracic echocardiographic examination was performed within 4 h after cardioversion for all the patients in the CAPRAF (Candesartan in the Prevention of Relapsing Atrial Fibrillation) study. Cardioversion was successful for 137 patients not given specific antiarrhythmic therapy, and only 41 (30%) maintained sinus rhythm at 6-month follow-up. There were significant (p = 0.05) lower transmitral A wave velocities in the group with relapsing atrial fibrillation compared with the group with sinus rhythm at 6-month follow-up. All patients with the lowest A wave velocities had an early recurrence of atrial fibrillation. There were no differences between the groups regarding atrial dimensions or left ventricular function. The use of the angiotensin II receptor antagonist candesartan had no influence on the echocardiographic variables, nor on the recurrence rate of atrial fibrillation after cardioversion. Transthoracic echocardiographic examination performed a short time after electrical cardioversion of atrial fibrillation showed that only A wave peak velocities were significantly predictive of sinus rhythm maintenance 6 months after the procedure. (c) 2008 S. Karger AG, Basel.

  15. Applying non-linear dynamics to atrial appendage flow data to understand and characterize atrial arrhythmia

    International Nuclear Information System (INIS)

    Chandra, S.; Grimm, R.A.; Katz, R.; Thomas, J.D.

    1996-01-01

    The aim of this study was to better understand and characterize left atrial appendage flow in atrial fibrillation. Atrial fibrillation and flutter are the most common cardiac arrhythmias affecting 15% of the older population. The pulsed Doppler velocity profile data was recorded from the left atrial appendage of patients using transesophageal echocardiography. The data was analyzed using Fourier analysis and nonlinear dynamical tools. Fourier analysis showed that appendage mechanical frequency (f f ) for patients in sinus rhythm was always lower (around1 Hz) than that in atrial fibrillation (5-8 Hz). Among patients with atrial fibrillation spectral power below f f was significantly different suggesting variability within this group of patients. Results that suggested the presence of nonlinear dynamics were: a) the existence of two arbitrary peak frequencies f 1 , f 2 , and other peak frequencies as linear combinations thereof (mf 1 ±nf 2 ), and b) the similarity between the spectrum of patient data and that obtained using the Lorenz equation. Nonlinear analysis tools, including Phase plots and differential radial plots, were also generated from the velocity data using a delay of 10. In the phase plots, some patients displayed a torus-like structure, while others had a more random-like pattern. In the differential radial plots, the first set of patients (with torus-like phase plots) showed fewer values crossing an arbitrary threshold of 10 than did the second set (8 vs. 27 in one typical example). The outcome of cardioversion was different for these two set of patients. Fourier analysis helped to: differentiate between sinus rhythm and atrial fibrillation, understand the characteristics of the wide range of atrial fibrillation patients, and provide hints that atrial fibrillation could be a nonlinear process. Nonlinear dynamical tools helped to further characterize and sub-classify atrial fibrillation

  16. An elusive persistent left superior vena cava draining into left atrium

    NARCIS (Netherlands)

    A. Soward; F.J. ten Cate (Folkert); P.M. Fioretti (Paolo); P.W.J.C. Serruys (Patrick); J.R.T.C. Roelandt (Jos)

    1986-01-01

    textabstractA case report of a persistent left superior vena cava draining into left atrium with a fibromuscular left ventricular outflow tract obstruction and a small atrial septal defect. The anomalous vessel escaped detection during two right and left heart catheterizations from the right arm and

  17. Entropy measurements in paroxysmal and persistent atrial fibrillation

    International Nuclear Information System (INIS)

    Cervigón, R; Moreno, J; Pérez-Villacastín, J; Reilly, R B; Millet, J; Castells, F

    2010-01-01

    Recent studies on atrial fibrillation (AF) have identified different activation patterns in paroxysmal and persistent AF. In this study, bipolar intra-atrial registers from 28 patients (14 paroxysmal AF and 14 persistent AF) were analyzed in order to find out regional differences in the organization in both types of arrhythmias. The organization of atrial electrical activity was assessed in terms of nonlinear parameters, such as entropy measurements. Results showed differences between the atrial chambers with a higher disorganization in the left atrium in paroxysmal AF patients and a more homogenous behavior along the atria in persistent AF patients

  18. Digoxin for atrial fibrillation and atrial flutter

    DEFF Research Database (Denmark)

    Sethi, Naqash J; Nielsen, Emil E; Safi, Sanam

    2018-01-01

    BACKGROUND: During recent years, systematic reviews of observational studies have compared digoxin to no digoxin in patients with atrial fibrillation or atrial flutter, and the results of these reviews suggested that digoxin seems to increase the risk of all-cause mortality regardless...... of concomitant heart failure. Our objective was to assess the benefits and harms of digoxin for atrial fibrillation and atrial flutter based on randomized clinical trials. METHODS: We searched CENTRAL, MEDLINE, Embase, LILACS, SCI-Expanded, BIOSIS for eligible trials comparing digoxin versus placebo......, no intervention, or other medical interventions in patients with atrial fibrillation or atrial flutter in October 2016. Our primary outcomes were all-cause mortality, serious adverse events, and quality of life. Our secondary outcomes were heart failure, stroke, heart rate control, and conversion to sinus rhythm...

  19. Atrial fibrillation or flutter

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/000184.htm Atrial fibrillation or flutter To use the sharing features on this page, please enable JavaScript. Atrial fibrillation or flutter is a common type of abnormal ...

  20. Atrial fibrillation - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000237.htm Atrial fibrillation - discharge To use the sharing features on this ... have been in the hospital because you have atrial fibrillation . This condition occurs when your heart beats faster ...

  1. Atrial Fibrillation - Multiple Languages

    Science.gov (United States)

    ... Are Here: Home → Multiple Languages → All Health Topics → Atrial Fibrillation URL of this page: https://medlineplus.gov/languages/ ... V W XYZ List of All Topics All Atrial Fibrillation - Multiple Languages To use the sharing features on ...

  2. Atrial Fibrillation: Complications

    Science.gov (United States)

    ... of this page please turn JavaScript on. Feature: Atrial Fibrillation Atrial Fibrillation: Complications Past Issues / Winter 2015 Table of Contents ... has two major complications—stroke and heart failure. Atrial Fibrillation and Stroke Click to enlarge image This illustration ...

  3. Recurrence of pulmonary vein conduction and atrial fibrillation after pulmonary vein isolation for atrial fibrillation

    DEFF Research Database (Denmark)

    Nilsson, Brian; Chen, Xu; Pehrson, Steen

    2006-01-01

    BACKGROUND: Both segmental ostial and circumferential extraostial pulmonary vein (PV) isolation have been proven effective in the treatment of atrial fibrillation (AF). However, the recurrence of AF and PV conduction after the 2 ablation strategies has never been compared in a randomized study...... isolation. Extraostial PV isolation was performed by encircling the paired left and right PVs, respectively, guided by an electroanatomic mapping system. RESULTS: A total of 84% of the patients had recurrent AF after the first PV isolation procedure, showing 72% with AF and 12% with organized left atrial...

  4. Effect of atrial systole on canine and porcine coronary blood flow.

    Science.gov (United States)

    Bellamy, R F

    1981-09-01

    A feature of phasic coronary flow patterns recorded in conscious chronically instrumented dogs is the atrial cove--a transient depression of arterial flow that occurs during atrial systole. The association between the hemodynamic effects of atrial systole and the atrial cove was studied in anesthetized dogs and pigs with complete heart block. Many atrial coves are available for study in these preparations because atrial activity continues unabated during the diastolic ventricular arrest that follows cessation of electrical pacing. The effect of atrial systole is to translate the pressure-flow relation found during diastole to a higher intercept pressure without change in slope. The increase in the intercept pressure equals the increase in intramyocardial pressure measured with microtransducers embedded in the left ventricular wall. The decrement in flow during the atrial cove is a direct function of the change in intramyocardial pressure and an inverse function of coronary vascular resistance. Each atrial systole is associated with a forward flow transient in the coronary veins, the peak of which occurs at the same instant as does the nadir of atrial flow. These data suggest that the coronary vessels are acting as collapsible tubes and that the waterfall model of the coronary circulation is applicable. The following sequence is proposed to account for the atrial cove. Atrial systole ejects a bolus of blood into the left ventricle increasing both ventricular cavity and intramyocardial pressures. The increase in intramyocardial pressure raises the back pressure opposing coronary flow, reducing the arterial perfusion pressure gradient and causing flow to fall.

  5. Atrial antitachycardia pacing and atrial remodeling: A substudy of the international, randomized MINERVA trial.

    Science.gov (United States)

    Boriani, Giuseppe; Tukkie, Raymond; Biffi, Mauro; Mont, Lluis; Ricci, Renato; Pürerfellner, Helmut; Botto, Giovanni Luca; Manolis, Antonis S; Landolina, Maurizio; Gulizia, Michele; Hudnall, J Harrison; Mangoni, Lorenza; Grammatico, Andrea; Padeletti, Luigi

    2017-10-01

    Atrial tachycardia (AT) and atrial fibrillation (AF) are common in pacemaker patients and are associated with bad prognoses. The purpose of this study was to evaluate atrial antitachycardia pacing impact on AT/AF-induced atrial remodeling, measured by early recurrence of AT/AF (ERAF) and by change in left atrial diameter (LAD), and to evaluate the impact of AT/AF duration on ERAF incidence. Pacemaker patients were randomized to dual-chamber pacing (Control DDDR: 385 patients), managed ventricular pacing (MVP: 398 patients), or atrial antitachycardia pacing plus MVP (DDDRP+MVP: 383 patients). LAD change, estimated by echocardiography, was considered significant if the relative difference between baseline and 24-month measurements was >10%. At median follow-up of 34 months, ERAF incidence was significantly lower in the DDDRP+MVP arm for all AT/AF durations, in particular, ERAF followed AT/AF longer than 3 hours in 53% cases in Control DDDR, in 51% cases in MVP, and in 39% cases in DDDRP+MVP (P MVP, and 70% in DDDRP+MVP (P MVP, DDDRP+MVP reduces ERAF and favors LAD reduction, suggesting that atrial antitachycardia pacing may reverse electrical and mechanical remodeling. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  6. Possible role of rivaroxaban in attenuating pressure-overload-induced atrial fibrosis and fibrillation.

    Science.gov (United States)

    Kondo, Hidekazu; Abe, Ichitaro; Fukui, Akira; Saito, Shotaro; Miyoshi, Miho; Aoki, Kohei; Shinohara, Tetsuji; Teshima, Yasushi; Yufu, Kunio; Takahashi, Naohiko

    2018-03-01

    Coagulation factor Xa (FXa) promotes thrombus formation and exacerbates inflammation via activation of protease-activated receptor (PAR)-2. We tested the hypothesis of whether administration of direct oral anticoagulant, rivaroxaban, would attenuate transverse aortic constriction (TAC)-induced atrial inflammatory fibrosis and vulnerability to atrial fibrillation (AF) in mice. Ten-week-old male CL57/B6 mice were divided into a sham-operation (CNT) group and TAC-surgery group. These two groups were then subdivided into vehicle (VEH) and rivaroxaban (RVX) treatment (30μg/g/day) groups. We assessed PAR-2 expression in response to TAC-related stimulation using rat cultured cells. TAC-induced left atrial thrombus formation was not observed in the TAC-RVX group. Cardiac PAR-2 upregulation was observed in both TAC groups. In the quantitative analysis of mRNA levels, cardiac PAR-2 upregulation was attenuated in the TAC-RVX group compared to TAC-VEH group. In histological evaluation, the TAC-VEH group showed cardiac inhomogeneous interstitial fibrosis and abundant infiltration of macrophages, which were attenuated by RVX administration. Electrophysiological examination revealed that AF duration in the TAC group was shortened by RVX administration. TAC-induced protein overexpression of monocyte chemoattractant protein-1, and mRNA overexpression of tumor necrosis factor-α, interleukin (IL)-1β and IL-6 in the left atrium was suppressed by RVX treatment. In cardiac fibroblasts, persistent intermittent stretch upregulated PAR-2, which was suppressed by RVX pre-incubation. These observations demonstrate that coagulation FXa inhibitor probably has a cardioprotective effect against pressure-overload-induced atrial remodeling. Copyright © 2017 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  7. Voltage sensitivity of M2 muscarinic receptors underlies the delayed rectifier-like activation of ACh-gated K(+) current by choline in feline atrial myocytes.

    Science.gov (United States)

    Navarro-Polanco, Ricardo A; Aréchiga-Figueroa, Iván A; Salazar-Fajardo, Pedro D; Benavides-Haro, Dora E; Rodríguez-Elías, Julio C; Sachse, Frank B; Tristani-Firouzi, Martin; Sánchez-Chapula, José A; Moreno-Galindo, Eloy G

    2013-09-01

    Choline (Ch) is a precursor and metabolite of the neurotransmitter acetylcholine (ACh). In canine and guinea pig atrial myocytes, Ch was shown to activate an outward K(+) current in a delayed rectifier fashion. This current has been suggested to modulate cardiac electrical activity and to play a role in atrial fibrillation pathophysiology. However, the exact nature and identity of this current has not been convincingly established. We recently described the unique ligand- and voltage-dependent properties of muscarinic activation of ACh-activated K(+) current (IKACh) and showed that, in contrast to ACh, pilocarpine induces a current with delayed rectifier-like properties with membrane depolarization. Here, we tested the hypothesis that Ch activates IKACh in feline atrial myocytes in a voltage-dependent manner similar to pilocarpine. Single-channel recordings, biophysical profiles, specific pharmacological inhibition and computational data indicate that the current activated by Ch is IKACh. Moreover, we show that membrane depolarization increases the potency and efficacy of IKACh activation by Ch and thus gives the appearance of a delayed rectifier activating K(+) current at depolarized potentials. Our findings support the emerging concept that IKACh modulation is both voltage- and ligand-specific and reinforce the importance of these properties in understanding cardiac physiology.

  8. Atrial and ventricular septal defect with pulmonary and tricuspid valvular anomalies in a dog

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, Y. [Azabu Univ., Sagamihara, Kanagawa (Japan); Wakao, Y.; Watanabe, T.; Minami, T.; Muto, M.; Suzuki, T.; Takahashi, M.; Une, Y.; Nomura, Y.; Ichioka, N.

    1989-12-15

    A 15-month-old male boxer dog weighing 22 kg was referred to Azabu University Animal Hospital for evaluation of the syncopal attack. There was no cardiac murmur, but electrocardiograms revealed an atrial fibrillation. Thoracic radiograph revealed enlargement of the right and left atrial regions. The medical treatment with digitalis and captopril was made for conversion from the atrial fibrillation to the sinus rhythm. By cardiac catheterization, atrial and ventricular septal defect with pulmonary stenosis was demonstrated. The patient died at 20 months from the first medical examination. At autopsy, there were severe enlargement of both atria, atrial defect, and pulmonary and tricuspid valvular anomalies. (author)

  9. Atrial and ventricular septal defect with pulmonary and tricuspid valvular anomalies in a dog

    International Nuclear Information System (INIS)

    Ishikawa, Y.; Wakao, Y.; Watanabe, T.; Minami, T.; Muto, M.; Suzuki, T.; Takahashi, M.; Une, Y.; Nomura, Y.; Ichioka, N.

    1989-01-01

    A 15-month-old male boxer dog weighing 22 kg was referred to Azabu University Animal Hospital for evaluation of the syncopal attack. There was no cardiac murmur, but electrocardiograms revealed an atrial fibrillation. Thoracic radiograph revealed enlargement of the right and left atrial regions. The medical treatment with digitalis and captopril was made for conversion from the atrial fibrillation to the sinus rhythm. By cardiac catheterization, atrial and ventricular septal defect with pulmonary stenosis was demonstrated. The patient died at 20 months from the first medical examination. At autopsy, there were severe enlargement of both atria, atrial defect, and pulmonary and tricuspid valvular anomalies. (author)

  10. Extreme variation in the atrial septation of caecilians (Amphibia: Gymnophiona)

    Science.gov (United States)

    de Bakker, Desiderius M; Wilkinson, Mark; Jensen, Bjarke

    2015-01-01

    Caecilians (order Gymnophiona) are elongate, limbless, snake-like amphibians that are the sister-group (closest relatives) of all other recent amphibians (frogs and salamanders). Little is known of their cardiovascular anatomy and physiology, but one nearly century old study suggests that Hypogeophis (family Indotyphlidae), commonly relied upon as a representative caecilian species, has atrial septation in the frontal plane and more than one septum. In contrast, in other vertebrates there generally is one atrial septum in the sagittal plane. We studied the adult heart of Idiocranium (also Indotyphlidae) using immunohistochemistry and confirm that the interatrial septum is close to the frontal plane. Additionally, a parallel right atrial septum divides three-fourths of the right atrial cavity of this species. Idiocranium embryos in the Hill collection reveal that atrial septation initiates in the sagittal plane as in other tetrapods. Late developmental stages, however, see a left-ward shift of visceral organs and a concordant rotation of the atria that reorients the atrial septa towards the frontal plane. The gross anatomies of species from six other caecilian families reveal that (i) the right atrial septum developed early in caecilian evolution (only absent in Rhinatrematidae) and that (ii) rotation of the atria evolved later and its degree varies between families. In most vertebrates a prominent atrial trabeculation associates with the sinuatrial valve, the so-called septum spurium, and the right atrial septum seems homologous to this trabeculation but much more developed. The right atrial septum does not appear to be a consequence of body elongation because it is absent in some caecilians and in snakes. The interatrial septum of caecilians shares multiple characters with the atrial septum of lungfishes, salamanders and the embryonic septum primum of amniotes. In conclusion, atrial septation in caecilians is based on evolutionarily conserved structures but

  11. A variant of fibroblast growth factor receptor 2 (Fgfr2 regulates left-right asymmetry in zebrafish.

    Directory of Open Access Journals (Sweden)

    Da-Wei Liu

    Full Text Available Many organs in vertebrates are left-right asymmetrical located. For example, liver is at the right side and stomach is at the left side in human. Fibroblast growth factor (Fgf signaling is important for left-right asymmetry. To investigate the roles of Fgfr2 signaling in zebrafish left-right asymmetry, we used splicing blocking morpholinos to specifically block the splicing of fgfr2b and fgfr2c variants, respectively. We found that the relative position of the liver and the pancreas were disrupted in fgfr2c morphants. Furthermore, the left-right asymmetry of the heart became random. Expression pattern of the laterality controlling genes, spaw and pitx2c, also became random in the morphants. Furthermore, lefty1 was not expressed in the posterior notochord, indicating that the molecular midline barrier had been disrupted. It was also not expressed in the brain diencephalon. Kupffer's vesicle (KV size became smaller in fgfr2c morphants. Furthermore, KV cilia were shorter in fgfr2c morphants. We conclude that the fgfr2c isoform plays an important role in the left-right asymmetry during zebrafish development.

  12. A variant of fibroblast growth factor receptor 2 (Fgfr2) regulates left-right asymmetry in zebrafish.

    Science.gov (United States)

    Liu, Da-Wei; Hsu, Chia-Hao; Tsai, Su-Mei; Hsiao, Chung-Der; Wang, Wen-Pin

    2011-01-01

    Many organs in vertebrates are left-right asymmetrical located. For example, liver is at the right side and stomach is at the left side in human. Fibroblast growth factor (Fgf) signaling is important for left-right asymmetry. To investigate the roles of Fgfr2 signaling in zebrafish left-right asymmetry, we used splicing blocking morpholinos to specifically block the splicing of fgfr2b and fgfr2c variants, respectively. We found that the relative position of the liver and the pancreas were disrupted in fgfr2c morphants. Furthermore, the left-right asymmetry of the heart became random. Expression pattern of the laterality controlling genes, spaw and pitx2c, also became random in the morphants. Furthermore, lefty1 was not expressed in the posterior notochord, indicating that the molecular midline barrier had been disrupted. It was also not expressed in the brain diencephalon. Kupffer's vesicle (KV) size became smaller in fgfr2c morphants. Furthermore, KV cilia were shorter in fgfr2c morphants. We conclude that the fgfr2c isoform plays an important role in the left-right asymmetry during zebrafish development.

  13. Atrial fibrillation.

    Science.gov (United States)

    Bang, Casper N

    2013-10-01

    Atrial fibrillation (AF) is a common complication after myocardial infarction (MI) and new-onset AF has been demonstrated to be associated with adverse outcome and a large excess risk of death in both MI and aortic stenosis (AS) patients. Prevention of new-onset AF is therefore a potential therapeutic target in AS and MI patients. Lipid-lowering drugs, particularly statins, have anti-inflammatory and antioxidant properties that may prevent AF. Accordingly, statins are recommended as a class IIa recommendation for prevention of new-onset AF after coronary artery bypass grafting (CABG). However, this preventive effect has not been investigated on new-onset AF in asymptomatic patients with AS or a large scale first-time MI patient sample and data in patients not undergoing invasive cardiac interventions are limited. This PhD thesis was conducted at the Heart Centre, Rigshospitalet, Denmark, with the aim to investigate the three aforementioned questions and to add to the existing evidence of AF prevention with statins. This was done using three different settings: 1) a randomized patients sample of 1,873 from the Simvastatin and Ezetimibe in Aortic Stenosis (SEAS) study, 2) a register patient sample of 97,499 with first-time MI, and 3) all published studies until beginning of June 2011 examining statin treatment on new-onset and recurrent AF in patients not undergoing cardiac surgery. This thesis revealed that statins did not lower the incidence or the time to new-onset AF in patients with asymptomatic AS. However, statin treatment showed an independently preventive effect on new-onset AF, including type-dependent effect and a trend to dosage-dependent effect. In addition, this thesis showed that good compliance to statin treatment was important to prevent new-onset AF. Finally, the meta-analysis in this PhD thesis showed a preventive effect in the observational studies although this effect was absent in the randomized controlled trials. Based on this PhD thesis

  14. Inhibition of cAMP-Dependent PKA Activates β2-Adrenergic Receptor Stimulation of Cytosolic Phospholipase A2 via Raf-1/MEK/ERK and IP3-Dependent Ca2+ Signaling in Atrial Myocytes.

    Science.gov (United States)

    Pabbidi, M R; Ji, X; Maxwell, J T; Mignery, G A; Samarel, A M; Lipsius, S L

    2016-01-01

    We previously reported in atrial myocytes that inhibition of cAMP-dependent protein kinase (PKA) by laminin (LMN)-integrin signaling activates β2-adrenergic receptor (β2-AR) stimulation of cytosolic phospholipase A2 (cPLA2). The present study sought to determine the signaling mechanisms by which inhibition of PKA activates β2-AR stimulation of cPLA2. We therefore determined the effects of zinterol (0.1 μM; zint-β2-AR) to stimulate ICa,L in atrial myocytes in the absence (+PKA) and presence (-PKA) of the PKA inhibitor (1 μM) KT5720 and compared these results with atrial myocytes attached to laminin (+LMN). Inhibition of Raf-1 (10 μM GW5074), phospholipase C (PLC; 0.5 μM edelfosine), PKC (4 μM chelerythrine) or IP3 receptor (IP3R) signaling (2 μM 2-APB) significantly inhibited zint-β2-AR stimulation of ICa,L in-PKA but not +PKA myocytes. Western blots showed that zint-β2-AR stimulation increased ERK1/2 phosphorylation in-PKA compared to +PKA myocytes. Adenoviral (Adv) expression of dominant negative (dn) -PKCα, dn-Raf-1 or an IP3 affinity trap, each inhibited zint-β2-AR stimulation of ICa,L in + LMN myocytes compared to control +LMN myocytes infected with Adv-βgal. In +LMN myocytes, zint-β2-AR stimulation of ICa,L was enhanced by adenoviral overexpression of wild-type cPLA2 and inhibited by double dn-cPLA2S505A/S515A mutant compared to control +LMN myocytes infected with Adv-βgal. In-PKA myocytes depletion of intracellular Ca2+ stores by 5 μM thapsigargin failed to inhibit zint-β2-AR stimulation of ICa,L via cPLA2. However, disruption of caveolae formation by 10 mM methyl-β-cyclodextrin inhibited zint-β2-AR stimulation of ICa,L in-PKA myocytes significantly more than in +PKA myocytes. We conclude that inhibition of PKA removes inhibition of Raf-1 and thereby allows β2-AR stimulation to act via PKCα/Raf-1/MEK/ERK1/2 and IP3-mediated Ca2+ signaling to stimulate cPLA2 signaling within caveolae. These findings may be relevant to the remodeling of

  15. Mid-Term Results of Surgical Treatment of Atrial Fibrillation in Valvular Heart Disease Assesed by Speckle Tracking Echocardiography.

    Science.gov (United States)

    Lorenzo, Natalia; Mendez, Irene; Taibo, Mikel; Martinis, Gianfranco; Badia, Sara; Reyes, Guillermo; Aguilar, Rio

    2018-03-19

    Atrial fibrillation frequently affects patients with valvular heart disease. Ablation of atrial fibrillation during valvular surgery is an alternative for restoring sinus rhythm. This study aimed to evaluate mid-term results of successful atrial fibrillation surgical ablation during valvular heart disease surgery, to explore left atrium post-ablation mechanics and to identify predictors of recurrence. Fifty-three consecutive candidates were included. Eligibility criteria for ablation included persistent atrial fibrillation valvular heart disease surgery.

  16. Observation of the efficacy of radiofrequency catheter ablation on patients with different forms of atrial fibrillation.

    Science.gov (United States)

    Zhao, R-C; Han, W; Han, J; Yu, J; Guo, J; Fu, J-L; Li, Z; Zhao, R-Z

    2016-10-01

    To study the efficacy and safety of radiofrequency catheter ablation (RFCA) in patients with different forms of atrial fibrillation. By retrospective analysis, we summarize 720 cases, where patients diagnosed with atrial fibrillation in our hospital were treated with RFCA from February 2010 to October 2014. Among the cases, 425 were diagnosed with paroxysmal atrial fibrillation and 295 with non-paroxysmal atrial fibrillation (including persistent atrial fibrillation and permanent atrial fibrillation). All patients were followed up until June 2015 to compare and analyze the differences in operation success rates, complications and recurrence rates. 395 cases (92.9%) of paroxysmal atrial fibrillation and 253 cases (85.8%) with non-paroxysmal atrial fibrillation were subject to surgery and followed up. The age of onset, disease course, underlying diseases, left atrial diameter and combined anti-arrhythmics of patients with paroxysmal atrial fibrillation were lower than those of patients with non-paroxysmal atrial fibrillation, and the differences were statistically significant (p success rate of the first ablation was higher than that of non-paroxysmal atrial fibrillation. Procedure time, procedure method, complications and recurrence rate of patients with paroxysmal atrial fibrillation were lower than those of non-paroxysmal atrial fibrillation group, and the differences were statistically significant (p failure caused by atrial fibrillation in the two groups, the difference was not statistically significant (Apoplexy: p = 0.186; Heart failure: p = 0.170). The individual ablation success rate was higher for paroxysmal atrial fibrillation, and long-term follow-up showed that the occurrence of apoplexy and heart failure was not different from the non-paroxysmal atrial fibrillation group.

  17. Ventricular rhythm in atrial fibrillation under anaesthetic infusion with propofol

    International Nuclear Information System (INIS)

    Cervigón, R; Moreno, J; Pérez-Villacastín, J; Reilly, R B; Castells, F

    2009-01-01

    Changes in patients' autonomic tone and specific pharmacologic interventions may modify the ventricular response (actual heart rate) during atrial fibrillation (AF). Hypnotic agents such as propofol may modify autonomic balance as they promote a sedative state. It has been shown that propofol slightly slows atrial fibrillatory activity, but the net global effect on the ventricular response remains unknown. We aimed to evaluate in patients in AF the effect of a propofol bolus on the ventricular rate and regularity at ECG. We analysed the possible relation with local atrial fibrillatory activities, as ratios between atrial and ventricular rates (AVRs), analysing atrial activity from intracardiac electrograms at the free wall of the right and left atria and at the interatrial septum. We compared data at the baseline and after complete hypnosis. Propofol was associated with a more homogeneous ventricular response and lower AVR values at the interatrial septum

  18. The atrial fibrillation ablation pilot study

    DEFF Research Database (Denmark)

    Arbelo, Elena; Brugada, Josep; Hindricks, Gerhard

    2014-01-01

    AIMS: The Atrial Fibrillation Ablation Pilot Study is a prospective registry designed to describe the clinical epidemiology of patients undergoing an atrial fibrillation (AFib) ablation, and the diagnostic/therapeutic processes applied across Europe. The aims of the 1-year follow-up were to analyse...... was achieved in 40.7% of patients (43.7% in paroxysmal AF; 30.2% in persistent AF; 36.7% in long-lasting persistent AF). A second ablation was required in 18% of the cases and 43.4% were under antiarrhythmic treatment. Thirty-three patients (2.5%) suffered an adverse event, 272 (21%) experienced a left atrial...... tachycardia, and 4 patients died (1 haemorrhagic stroke, 1 ventricular fibrillation in a patient with ischaemic heart disease, 1 cancer, and 1 of unknown cause). CONCLUSION: The AFib Ablation Pilot Study provided crucial information on the epidemiology, management, and outcomes of catheter ablation of AFib...

  19. Symptomatic paroxysmal atrial fibrillation in a patient with unilateral pulmonary vein atresia

    Directory of Open Access Journals (Sweden)

    Sharmila Sehli

    2015-01-01

    Full Text Available A 52-year-old man with symptomatic paroxysmal atrial fibrillation was offered an atrial fibrillation (AF ablation procedure. His echocardiogram indicated that he had no structural heart disease. A cardiac computed tomographic (CT scan showed enlargement of the right pulmonary veins, absence of the left pulmonary veins, a prominent left atrial appendage, and a hypoplastic left lung. Cardiac CT with an electroanatomic mapping system confirmed a prominent left atrial appendage and the absence of the left pulmonary veins. Due to the limited number of patients with this condition, information about ablation remains very limited, and his ablation was deferred. Unilateral pulmonary vein atresia is a rare condition in adults which results from failure of incorporation of the common pulmonary vein into the left atrium. This case demonstrates the clinical importance of preprocedural imaging prior to AF ablation.

  20. Right atrial isolation associated with atrial septal closure in patients with atrial septal defect and chronic atrial fibrillation.

    Science.gov (United States)

    Minzioni, G; Graffigna, A; Pagani, F; Vigano, M

    1993-12-01

    To restore sinus rhythm in the remaining heart chambers of six adult patients with atrial septal defect and chronic or paroxysmal atrial fibrillation, electrical, right atrial isolation associated with surgical correction of the defect was performed. All but one patient was free from atrial fibrillation without medication 2-25 months after operation. The isolated right atrial appendages showed intrinsic rhythmical activity in five patients and no electrical activity in one. Right atrial isolation is a safe and effective procedure that abolishes atrial fibrillation in patients with arrhythmia after surgical correction of atrial septal defect.

  1. Antihypertensive treatment and risk of atrial fibrillation

    DEFF Research Database (Denmark)

    Marott, Sarah C W; Nielsen, Sune F; Benn, Marianne

    2014-01-01

    AIMS: To examine the associations between antihypertensive treatment with angiotensin-converting enzyme inhibitors (ACEis) or angiotensin receptor blockers (ARBs), β-blockers, diuretics, or calcium-antagonists, and risk of atrial fibrillation. We examined these associations using the entire Danish...... population from 1995 through 2010. METHODS AND RESULTS: Excluding medication used in atrial fibrillation, we matched individuals on ACEi monotherapy 1:1 with individuals on β-blocker (n = 48 658), diuretic (n = 69 630), calcium-antagonist (n = 57 646), and ARB monotherapy (n = 20 158). Likewise, individuals...... on ARB monotherapy were matched 1:1 with individuals on β-blocker (n = 20 566), diuretic (n = 20 832), calcium-antagonist (n = 20 232), and ACEi monotherapy (n = 20 158). All were free of atrial fibrillation and of predisposing diseases like heart failure, ischaemic heart disease, diabetes mellitus...

  2. Late bacterial endocarditis of an Amplatzer atrial septal device

    Directory of Open Access Journals (Sweden)

    Bhavith Aruni

    2013-07-01

    Full Text Available A 59-year-old male with an secundum atrial septal defect status post repair with an Amplatzer occluder in 2001 was admitted with sepsis and MRSA bacteremia. Transesophageal Echocardiography (TEE showed presence of an overlying mobile echogenic structure on the left atrial surface of the device suggestive of a vegetation/infected thrombus. This is only the 3rd case description of late endocarditis involving the Amplatzer ASD closure device in an adult.

  3. Atrial arrhythmia in ageing spontaneously hypertensive rats: unraveling the substrate in hypertension and ageing.

    Directory of Open Access Journals (Sweden)

    Dennis H Lau

    Full Text Available BACKGROUND: Both ageing and hypertension are known risk factors for atrial fibrillation (AF although the pathophysiological contribution or interaction of the individual factors remains poorly understood. Here we aim to delineate the arrhythmogenic atrial substrate in mature spontaneously hypertensive rats (SHR. METHODS: SHR were studied at 12 and 15 months of age (n = 8 per group together with equal numbers of age-matched normotensive Wistar-Kyoto control rats (WKY. Electrophysiologic study was performed on superfused isolated right and left atrial preparations using a custom built high-density multiple-electrode array to determine effective refractory periods (ERP, atrial conduction and atrial arrhythmia inducibility. Tissue specimens were harvested for structural analysis. RESULTS: COMPARED TO WKY CONTROLS, THE SHR DEMONSTRATED: Higher systolic blood pressure (p<0.0001, bi-atrial enlargement (p<0.05, bi-ventricular hypertrophy (p<0.05, lower atrial ERP (p = 0.008, increased atrial conduction heterogeneity (p = 0.001 and increased atrial interstitial fibrosis (p = 0.006 & CD68-positive macrophages infiltration (p<0.0001. These changes resulted in higher atrial arrhythmia inducibility (p = 0.01 and longer induced AF episodes (p = 0.02 in 15-month old SHR. Ageing contributed to incremental bi-atrial hypertrophy (p<0.01 and atrial conduction heterogeneity (p<0.01 without affecting atrial ERP, fibrosis and arrhythmia inducibility. The limited effect of ageing on the atrial substrate may be secondary to the reduction in CD68-positive macrophages. CONCLUSIONS: Significant atrial electrical and structural remodeling is evident in the ageing spontaneously hypertensive rat atria. Concomitant hypertension appears to play a greater pathophysiological role than ageing despite their compounding effect on the atrial substrate. Inflammation is pathophysiologically linked to the pro-fibrotic changes in the hypertensive atria.

  4. VARIATION IN THE OPENINGS (OSTIA OF LEFT PULMONARY VEINS INTO THE LEFT ATRIUM: A CASE REPORT

    Directory of Open Access Journals (Sweden)

    Sesi

    2015-03-01

    Full Text Available During early embryonic development, absorption of pulmonary venous network by the left primitive atrial chamber results in opening of four pulmonary veins which drain independently into its chamber. The extent of absorption and hence, the number of pulmon ary veins which open into the left atrium, may vary. Here we report a variation in the opening of the Left upper (superior pulmonary vein into the Left atrium. A total of six openings observed

  5. Valsartan Reduced Atrial Fibrillation Susceptibility by Inhibiting Atrial Parasympathetic Remodeling through MAPKs/Neurturin Pathway

    Directory of Open Access Journals (Sweden)

    Lei Liu

    2015-07-01

    Full Text Available Background/Aims: Angiotensin II receptor blockers (ARBs have been proved to be effective in preventing atrial structural and electrical remodelinq in atrial fibrillation (AF. Previous studies have shown that parasympathetic remodeling plays an important role in AF. However, the effects of ARBs on atrial parasympathetic remodeling in AF and the underlying mechanisms are still unknown. Methods: Canines were divided into sham-operated, pacing and valsartan + pacing groups. Rats and HL-1 cardiomyocytes were divided into control, angiotensin II (Ang II and Ang II + valsartan groups, respectively. Atrial parasympathetic remodeling was quantified by immunocytochemical staining with anti-choline acetyltransferase (ChAT antibody. Western blot was used to analysis the protein expression of neurturin. Results: Both inducibility and duration were increased in chronic atrial rapid-pacing canine model, which was significantly inhibited by the treatment with valsartan. The density of ChAT-positive nerves and the protein level of neurturin in the atria of pacing canines were both increased than those in sham-operated canines. Ang II treatment not only induced atrial parasympathetic remodeling in rats, but also up-regulated the protein expression of neurturin. Valsartan significantly prevented atrial parasympathetic remodeling, and suppressed the protein expression of neurturin. Meanwhile, valsartan inhibited Ang II -induced up-regulation of neurturin and MAPKs in cultured cardiac myocytes. Inhibition of MAPKs dramatically attenuated neurturin up-regulation induced by Ang II. Conclusion: Parasympathetic remodeling was present in animals subjected to rapid pacing or Ang II infusion, which was mediated by MAPKs/neurturin pathway. Valsartan is able to prevent atrial parasympathetic remodeling and the occurrence of AF via inhibiting MAPKs/neurturin pathway.

  6. Valsartan Reduced Atrial Fibrillation Susceptibility by Inhibiting Atrial Parasympathetic Remodeling through MAPKs/Neurturin Pathway.

    Science.gov (United States)

    Liu, Lei; Geng, Jianqiang; Zhao, Hongwei; Yun, Fengxiang; Wang, Xiaoyu; Yan, Sen; Ding, Xue; Li, Wenpeng; Wang, Dingyu; Li, Jianqiang; Pan, Zhenwei; Gong, Yongtai; Tan, Xiangyang; Li, Yue

    2015-01-01

    Angiotensin II receptor blockers (ARBs) have been proved to be effective in preventing atrial structural and electrical remodelinq in atrial fibrillation (AF). Previous studies have shown that parasympathetic remodeling plays an important role in AF. However, the effects of ARBs on atrial parasympathetic remodeling in AF and the underlying mechanisms are still unknown. Canines were divided into sham-operated, pacing and valsartan + pacing groups. Rats and HL-1 cardiomyocytes were divided into control, angiotensin II (Ang II) and Ang II + valsartan groups, respectively. Atrial parasympathetic remodeling was quantified by immunocytochemical staining with anti-choline acetyltransferase (ChAT) antibody. Western blot was used to analysis the protein expression of neurturin. Both inducibility and duration were increased in chronic atrial rapid-pacing canine model, which was significantly inhibited by the treatment with valsartan. The density of ChAT-positive nerves and the protein level of neurturin in the atria of pacing canines were both increased than those in sham-operated canines. Ang II treatment not only induced atrial parasympathetic remodeling in rats, but also up-regulated the protein expression of neurturin. Valsartan significantly prevented atrial parasympathetic remodeling, and suppressed the protein expression of neurturin. Meanwhile, valsartan inhibited Ang II -induced up-regulation of neurturin and MAPKs in cultured cardiac myocytes. Inhibition of MAPKs dramatically attenuated neurturin up-regulation induced by Ang II. Parasympathetic remodeling was present in animals subjected to rapid pacing or Ang II infusion, which was mediated by MAPKs/neurturin pathway. Valsartan is able to prevent atrial parasympathetic remodeling and the occurrence of AF via inhibiting MAPKs/neurturin pathway. © 2015 S. Karger AG, Basel.

  7. Histopathologic analysis of atrial tissue in patients with atrial fibrillation: comparison between patients with atrial septal defect and patients with mitral valvular heart disease.

    Science.gov (United States)

    Kwak, Jae Gun; Seo, Jeong-Wook; Oh, Sam Se; Lee, Sang Yun; Ham, Eui Keun; Kim, Woong-Han; Kim, Soo-Jin; Bae, Eun Jung; Lim, Cheoung; Lee, Chang-Ha; Lee, Cheul

    2014-01-01

    Atrial fibrillation (AF) in adult patients with atrial septal defect (ASD) accompanies an enlarged right atrium (RA) with a less enlarged left atrium (LA), which is the opposite situation in patients with AF and mitral valvular disease. This study was to compare the histopathological change in the atrium of patients with AF of two different etiologies: ASD and mitral disease. Twenty-four patients were enrolled. Group 1 included patients with ASD (8), Group 2 included patients with ASD with AF (6), and Group 3 included patients with mitral disease with AF (10). Preoperative atrial volumes were measured. Atrial tissues were obtained during surgical procedures and stained with periodic acid-Schiff, smooth muscle actin, Sirius red, and Masson's trichrome to detect histopathologic changes compatible with AF. The severity of histopathological changes was represented with "positivity" and "strong positivity" after analyzing digitalized images of the staining. We investigated the relationship between the degree of atrial dilatation and severity of histopathological changes according to the groups and tissues. Group 2 and Group 3 patients showed a tendency toward an enlarged RA volume and enlarged LA volume, respectively, compared with each others. However, in the histopathologic analysis, "positivity" and "strong positivity" showed no significant positive correlations with the degree of atrial volume in special staining. A similar degree of histopathologic changes was observed in both atria in patients with AF (Group 2 and 3) regardless of the degree of dilatation of atrial volume and disease entities. Crown Copyright © 2014. Published by Elsevier Inc. All rights reserved.

  8. Structural and functional characteristics of myocard in patients with different forms of atrial fibrillation

    Directory of Open Access Journals (Sweden)

    L. I. Vasilyeva

    2015-02-01

    Full Text Available Aim. To study structural and functional characteristics of myocard in patients with different forms of atrial fibrillation. Atrial fibrillation is the most prevalent arrhythmia in clinical practice. Atrial fibrillation is a progressive disease: the duration of paroxysms increases over time and paroxysmal atrial fibrillation transforms to persistent, the last one becomes refractory to pharmacological and electrical cardioversion in time and transforms to permanent. So assessment of myocardial remodeling in patients with persistent and permanent atrial fibrillation is very actual. Methods and results. According to the aim of the study 133 patients with persistent atrial fibrillation and 100 patients with permanent atrial fibrillation were included into the study. Echocardiographic parameters of left and right atria function were studied. Conclusion. It was found that patients with persistent and permanent atrial fibrillation are characterized with both left and right atrias remodeling. Remodeling of the atrias is less pronounced in patients with permanent atrial fibrillation in comparison with persistent atrial fibrillation patients and arrhythmia recurrence.

  9. [Atrial fibrillation concomitant with valvular heart disease].

    Science.gov (United States)

    Ishii, Yosuke

    2013-01-01

    Patients with valvular heart disease frequently have atrial fibrillation(AF) due to elevated pressure and dilatation of the left and right atria and pulmonary veins. Guidelines for valvular heart disease and AF recommend that surgical treatment for the valvular heart disease should be performed concomitantly with AF surgery. The Full-Maze procedure has evolved into the gold standard of treatment for medically refractory AF. In addition to the pulmonary vein isolation, the right and left atrial incisions of the Full-Maze procedure are designed to block potential macroreentrant pathways. According to the mechanisms of AF with valvular heart disease, the Full-Maze procedure is more effective for the patients than the pulmonary vein isolation alone.

  10. Magnetic electroanatomical mapping for ablation of focal atrial tachycardias.

    Science.gov (United States)

    Marchlinski, F; Callans, D; Gottlieb, C; Rodriguez, E; Coyne, R; Kleinman, D

    1998-08-01

    Uniform success for ablation of focal atrial tachycardias has been difficult to achieve using standard catheter mapping and ablation techniques. In addition, our understanding of the complex relationship between atrial anatomy, electrophysiology, and surface ECG P wave morphology remains primitive. The magnetic electroanatomical mapping and display system (CARTO) offers an on-line display of electrical activation and/or signal amplitude related to the anatomical location of the recorded sites in the mapped chamber. A window of electrical interest is established based on signals timed from an electrical reference that usually represents a fixed electrogram recording from the coronary sinus or the atrial appendage. This window of electrical interest is established to include atrial activation prior to the onset of the P wave activity associated with the site of origin of a focal atrial tachycardia. Anatomical and electrical landmarks are defined with limited fluoroscopic imaging support and more detailed global chamber and more focal atrial mapping can be performed with minimal fluoroscopic guidance. A three-dimensional color map representing atrial activation or voltage amplitude at the magnetically defined anatomical sites is displayed with on-line data acquisition. This display can be manipulated to facilitate viewing from any angle. Altering the zoom control, triangle fill threshold, clipping plane, or color range can all enhance the display of a more focal area of interest. We documented the feasibility of using this single mapping catheter technique for localizing and ablating focal atrial tachycardias. In a consecutive series of 8 patients with 9 focal atrial tachycardias, the use of the single catheter CARTO mapping system was associated with ablation success in all but one patient who had a left atrial tachycardia localized to the medial aspect of the orifice of the left atrial appendage. Only low power energy delivery was used in this patient because of the

  11. Three-dimensional atrial wall thickness maps to inform catheter ablation procedures for atrial fibrillation.

    Science.gov (United States)

    Bishop, Martin; Rajani, Ronak; Plank, Gernot; Gaddum, Nicholas; Carr-White, Gerry; Wright, Matt; O'Neill, Mark; Niederer, Steven

    2016-03-01

    Transmural lesion formation is critical to success in atrial fibrillation ablation and is dependent on left atrial wall thickness (LAWT). Pre- and peri-procedural planning may benefit from LAWT measurements. To calculate the LAWT, the Laplace equation was solved over a finite element mesh of the left atrium derived from the segmented computed tomographic angiography (CTA) dataset. Local LAWT was then calculated from the length of field lines derived from the Laplace solution that spanned the wall from the endocardium or epicardium. The method was validated on an atrium phantom and retrospectively applied to 10 patients who underwent routine coronary CTA for standard clinical indications at our institute. The Laplace wall thickness algorithm was validated on the left atrium phantom. Wall thickness measurements had errors of atrial wall thickness measurements were performed on 10 patients. Successful comprehensive LAWT maps were generated in all patients from the coronary CTA images. Mean LAWT measurements ranged from 0.6 to 1.0 mm and showed significant inter and intra patient variability. Left atrial wall thickness can be measured robustly and efficiently across the whole left atrium using a solution of the Laplace equation over a finite element mesh of the left atrium. Further studies are indicated to determine whether the integration of LAWT maps into pre-existing 3D anatomical mapping systems may provide important anatomical information for guiding radiofrequency ablation. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  12. Long-term results of the corridor operation for atrial fibrillation

    NARCIS (Netherlands)

    van Hemel, N. M.; Defauw, J. J.; Kingma, J. H.; Jaarsma, W.; Vermeulen, F. E.; de Bakker, J. M.; Guiraudon, G. M.

    1994-01-01

    To investigate the long-term results of the corridor operation in the treatment of symptomatic atrial fibrillation refractory to drug treatment. The corridor operation is designed to isolate from the left and right atrium a conduit of atrial tissue connecting the sinus node area with the

  13. Atrial myxoma-related embolism resulting in acute limb ischaemia in ...

    African Journals Online (AJOL)

    Although atrial myxomas are uncommon, a thorough investigation of patients presenting with acute peripheral ischaemic .... reported.[9] Large left atrial tumours impairing intracardiac blood flow can ... In the case described here, obstruction of the mitral valve by the myxoma ... operation, preventing histological confirmation.

  14. Systolic and Diastolic Function by Tissue Doppler Imaging Predicts Mortality in Patients with Atrial Fibrillation

    DEFF Research Database (Denmark)

    Dons, Maria; BieringSørensen, Tor; Jensen, Jan Skov

    2015-01-01

    AIM: Tissue Doppler Imaging (TDI) detects early signs of left ventricular dysfunction. The prognostic potential of TDI in patients with atrial fibrillation (AF) has, however, not yet been clarified. This study evaluates the prognostic value of TDI in patients with atrial fibrillation. METHODS...

  15. Radiofrequency ablation of atrial tachyarrhythmias in adults with tetralogy of Fallot - predictors of success and outcome.

    Science.gov (United States)

    Ezzat, Vivienne A; Ryan, Matthew J; O'Leary, Justin; Ariti, Cono; Deanfield, John; Pandya, Bejal; Cullen, Shay; Walker, Fiona; Khan, Fakhar; Abrams, Dominic J; Lambiase, Pier D; Lowe, Martin D

    2017-03-01

    Adults with tetralogy of Fallot experience atrial tachyarrhythmias; however, there are a few data on the outcomes of radiofrequency ablation. We examined the characteristics, outcome, and predictors of recurrence of atrial tachyarrhythmias after radiofrequency ablation in tetralogy of Fallot patients. Methods/results Retrospective data were collected from 2004 to 2013. In total, 56 ablations were performed on 37 patients. We identified two matched controls per case: patients with tetralogy of Fallot but no radiofrequency ablation and not known to have atrial tachyarrhythmias. Acute success was 98%. Left atrial arrhythmias increased in frequency over time. The mean follow-up was 41 months; 78% were arrhythmia-free. Number of cardiac surgeries, age, and presence of atrial fibrillation were predictors of recurrence. Lone cavo-tricuspid isthmus-dependent flutter reduced the likelihood of atrial fibrillation. Right and left atria in patients with tetralogy of Fallot were larger in ablated cases than controls. NYHA class was worse in cases and improved after ablation; baseline status predicted death. Of matched non-ablated controls, a number of them had atrial fibrillation. These patients were excluded from the case-control study but analysed separately. Most of them had died during follow-up, whereas of the matched ablated cases all were alive and the majority in sinus rhythm. Patients with tetralogy of Fallot and atrial tachyarrhythmias have more dilated atria than those without atrial tachyarrhythmias. Radiofrequency ablation improves functional status. Left atrial ablation is more commonly required with repeat procedures. There is a high prevalence of atrial tachyarrhythmias, particularly atrial fibrillation, in patients with tetralogy of Fallot; early radiofrequency ablation may have a protective effect against this.

  16. Sex differences and left-right asymmetries in expression of insulin and insulin-like growth factor-1 receptors in developing rat hippocampus.

    Science.gov (United States)

    Hami, Javad; Sadr-Nabavi, Ariane; Sankian, Mojtaba; Haghir, Hossein

    2012-04-01

    Sex differences and laterality of rat hippocampus with respect to insulin-like growth factor-1 receptor (IGF-1R) and insulin receptor (InsR) expression as two important contributors to/regulators of developmental and cognitive functions were examined using real-time PCR and western blot analysis at P0, P7 and P14. Expression of the IGF-1R gene was lowest at P0 in all studied hippocampi. In males, we found the highest expression at P7 in the right hippocampus, and at P14 in the left one. In contrast, the peaked IGF-1R expression occurred at P7 in female hippocampi independent of laterality. Hippocampal InsR expression in males decreased significantly between P0 and P7, followed by a marked upregulation at P14. Conversely, the expression of InsR in females peaked at P7 and then decreased again significantly at P14. We found significant interhemispheric differences in IGF-1R mRNA levels in both male and female hippocampi at different time points. In contrast, we only found significant interhemispheric differences in InsR mRNA expression in P14 male rats, with higher values in the left hippocampus. Interestingly, changes in mRNA expression and in protein levels followed the same developmental pattern, indicating that IGF-1R and InsR transcription is not subject to modulatory effects during the first two weeks of development. These findings indicate that there are prominent interhemispheric and sex differences in IGF-1R and InsR expression in the developing rat hippocampus, suggesting a probable mechanism for the control of gender and laterality differences in development and function of the hippocampus.

  17. Analysis of immune cell populations in atrial myocardium of patients with atrial fibrillation or sinus rhythm.

    Directory of Open Access Journals (Sweden)

    Natalia Smorodinova

    Full Text Available Atrial fibrillation (AF is the most common arrhythmia and despite obvious clinical importance remains its pathogenesis only partially explained. A relation between inflammation and AF has been suggested by findings of increased inflammatory markers in AF patients.The goal of this study was to characterize morphologically and functionally CD45-positive inflammatory cell populations in atrial myocardium of patients with AF as compared to sinus rhythm (SR.We examined 46 subjects (19 with AF, and 27 in SR undergoing coronary bypass or valve surgery. Peroperative bioptic samples of the left and the right atrial tissue were examined using immunohistochemistry.The number of CD3+ T-lymphocytes and CD68-KP1+ cells were elevated in the left atrial myocardium of patients with AF compared to those in SR. Immune cell infiltration of LA was related to the rhythm, but not to age, body size, LA size, mitral regurgitation grade, type of surgery, systemic markers of inflammation or presence of diabetes or hypertension. Most of CD68-KP1+ cells corresponded to dendritic cell population based on their morphology and immunoreactivity for DC-SIGN. The numbers of mast cells and CD20+ B-lymphocytes did not differ between AF and SR patients. No foci of inflammation were detected in any sample.An immunohistochemical analysis of samples from patients undergoing open heart surgery showed moderate and site-specific increase of inflammatory cells in the atrial myocardium of patients with AF compared to those in SR, with prevailing population of monocyte-macrophage lineage. These cells and their cytokine products may play a role in atrial remodeling and AF persistence.

  18. Association of Atrial Fibrillation with Morphological and Electrophysiological Changes of the Atrial Myocardium.

    Science.gov (United States)

    Matějková, Adéla; Šteiner, Ivo

    Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia. For long time it was considered as pure functional disorder, but in recent years, there were identified atrial locations, which are involved in the initiation and maintenance of this arrhythmia. These structural changes, so called remodelation, start at electric level and later they affect contractility and morphology. In this study we attempted to find a possible relation between morphological (scarring, amyloidosis, left atrial (LA) enlargement) and electrophysiological (ECG features) changes in patients with AF. We examined grossly and histologically 100 hearts of necropsy patients - 54 with a history of AF and 46 without AF. Premortem ECGs were evaluated. The patients with AF had significantly heavier heart, larger LA, more severely scarred myocardium of the LA and atrial septum, and more severe amyloidosis in both atria. Severity of amyloidosis was higher in LAs vs. right atria (RAs). Distribution of both fibrosis and amyloidosis was irregular. The most affected area was in the LA anterior wall. Patients with a history of AF and with most severe amyloidosis have more often abnormally long P waves. Finding of long P wave may contribute to diagnosis of a hitherto undisclosed atrial fibrillation.

  19. Comunicação interatrial do tipo seio coronário, comunicação interventricular e ausência de veia cava superior esquerda Coronary sinus atrial septal defect and ventricular septal defect with no left superior vena cava

    Directory of Open Access Journals (Sweden)

    Fábio Alves Almeida

    1998-10-01

    Full Text Available Relatamos um caso raro de um paciente de 21 meses, portador de comunicação interatrial do tipo seio coronário, associada a comunicação interventricular perimembranosa, e ausência de veia cava superior esquerda. O diagnóstico foi realizado através da ecocardiografia e confirmado pela angiografia. O paciente foi operado sem intercorrências, ambos os defeitos foram fechados com patch de pericárdio bovino e o fluxo das veias coronárias ficou direcionado para o átrio esquerdo. Um ecocardiograma mostrou ausência de shunt residual através dos defeitos.We report a rare case of a 21 month old child with a coronary sinus atrial septal defect associated with perimembranous ventricular septal defect and no left superior vena cava. The diagnosis was made by transthoracic echocardiogram and confirmed by angiography. The patient was operated on uneventfully, both defects were closed with bovine pericardial patches and the flow from the coronary veins was directed towards the left atrium. An echocardiogram revealed complete closure of both defects.

  20. Demographic determinants and effect of pre-operative angiotensin converting enzyme inhibitors and angiotensin receptor blockers on the occurrence of atrial fibrillation after CABG surgery

    Directory of Open Access Journals (Sweden)

    Weiss Michael J

    2010-02-01

    Full Text Available Abstract Background Atrial fibrillation (AF occurs in about 27% to 40% of post cardiac surgery patients. AF following coronary artery bypass graft surgery (CABG is associated with a two-fold increase in morbidity and mortality. Various demographic risk factors and medications have been studied to predict the occurrence of this arrhythmia. The role of angiotensin related medications on the occurrence of AF in CABG patients is not determined. Methods Retrospective clinical and statistical analysis was made of all the patients who had undergone CABG surgery at Lehigh Valley Hospital during the years 2005 and 2006. Patients with chronic AF and those undergoing valvular surgery with CABG were excluded. Statistic analysis included chi-square test for categorical and student t-test for continuous variables. Results 757 patients (560 males and 197 females were studied. AF occurred in 19% of the patients. Age (70.5 vs. 65.1, p Conclusions Advanced age and presence of hypertension were independent predictors of post-CABG AF. Patients with post operative AF had significantly longer hospital stay. Neither ARBs nor ACE inhibitors were associated with reduction of post-surgical AF. Further studies are needed to better delineate the role of angiotensin related medications on reduction of post-surgical AF.

  1. Effects of a prostagrandin EP4-receptor agonist ONO-AE1-329 on the left ventricular pressure-volume relationship in the halothane-anesthetized dogs.

    Science.gov (United States)

    Honda, Atsushi; Nakamura, Yuji; Ohara, Hiroshi; Cao, Xin; Nomura, Hiroaki; Katagi, Jun; Wada, Takeshi; Izumi-Nakaseko, Hiroko; Ando, Kentaro; Sugiyama, Atsushi

    2016-03-15

    Cardiac effects of a prostagrandin EP4-receptor agonist ONO-AE1-329 were assessed in the halothane-anesthetized dogs under the monitoring of left ventricular pressure-volume relationship, which were compared with those of clinically recommended doses of dopamine, dobutamine and milrinone (n=4-5 for each treatment). ONO-AE1-329 was intravenously administered in doses of 0.3, 1 and 3 ng/kg/min for 10 min with a pause of 20 min. Dopamine in a dose of 3 µg/kg/min for 10 min, dobutamine in a dose of 1 µg/kg/min for 10 min and milrinone in a dose of 5 µg/kg/min for 10 min followed by 0.5 µg/kg/min for 10 min were intravenously administered. Low dose of ONO-AE1-329 increased the stroke volume. Middle dose of ONO-AE1-329 increased the cardiac output, left ventricular end-diastolic volume, ejection fraction, maximum upstroke/downstroke velocities of the left ventricular pressure and external work, but decreased the end-systolic pressure and internal work besides the change by the low dose. High dose of ONO-AE1-329 increased the heart rate and maximum elastance, but decreased the end-systolic volume besides the changes by the middle dose. Dopamine, dobutamine and milrinone exerted essentially similar cardiac effects to ONO-AE1-329, but they did not significantly change the end-diastolic volume, end-systolic volume, stroke volume, ejection fraction, end-systolic pressure, maximum elastance, external work or internal work. Thus, EP4-receptor stimulation by ONO-AE1-329 may have potential to better promote the passive ventricular filling than the conventional cardiotonic drugs, which could become a candidate of novel therapeutic strategy for the treatment of heart failure with preserved ejection fraction. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Antiarrhythmic properties of atrial pacing.

    Science.gov (United States)

    Kliś, Magdalena; Sławuta, Agnieszka; Gajek, Jacek

    2017-01-01

    Bradycardia, atrial stretch and dilatation, autonomic nervous system disorders, and the presence of triggers such as atrial premature contractions, are factors which predispose a person to paroxysmal AF. Atrial pacing not only eliminates bradycardia but also prevents atrial premature contractions and dispersion of refractoriness, which are a substrate for atrial fibrillation. As the prolonged duration of atrial activation during pacing, especially from locations changing the physiological pattern of this activation (right atrium lateral wall, right atrium appendage), negatively influences both a mechanical and an electrical function of the atria, the atrial pacing site affects an atrial arrhythmogenesis. A conventional atrial lead location in the right atrium appendage causes non-physiological activation propagation, resulting in a prolongation of the activation time of both atria. This location is optimal according to a passive fixation of the atrial lead but the available contemporary active fixation leads could potentially be located in any area of the atrium. There is growing evidence of the benefit of pacing, imitating the physiological propagation of impulses within the atria. It seems that the Bachmann's bundle pacing is the best pacing site within the atria, not only positively influencing the atrial mechanical function but also best fulfilling the so-called atrial resynchronization function, in particular in patients with interatrial conduction delay. It can be effectively achieved using only one atrial electrode, and the slight shortening of atrioventricular conduction provides an additional benefit of this atrial pacing site.

  3. What Is Atrial Fibrillation?

    Science.gov (United States)

    ANSWERS by heart Cardiovascular Conditions What Is Atrial Fibrillation? Your heart has a natural pacemaker, called the “sinus node,” that makes electrical signals. These signals cause the heart to contract and pump ...

  4. A new therapeutic strategy for electrical cardioversion of atrial fibrillation.

    Science.gov (United States)

    de Luca, I; Sorino, M; Del Salvatore, B; de Luca, L

    2001-11-01

    The conventional approach to cardioversion of atrial fibrillation includes a period of anticoagulation with oral anticoagulant therapy (OAT) extending from 3 weeks precardioversion to 4 weeks postcardioversion. The protocol of rapid anticoagulation (such as that of the ACUTE study) consists of a precardioversion transesophageal echocardiography (TEE) followed by OAT for 4 weeks. In the last few years low-molecular-weight heparins have established themselves as a safe and efficacious alternative to traditional antithrombotic therapies. The aim of this study was to demonstrate that the exclusion of thrombi by precardioversion TEE together with the exclusion of atrial stunning by a second TEE performed after 1 week, to date not suggested in the literature, could reduce to 7 days the period of pericardioversion anticoagulation. This therapy would be carried out using low-molecular-weight heparins with no need for biological monitoring and with the possibility of self-administration. We have studied 57 consecutive patients who had atrial fibrillation or flutter with a history of atrial fibrillation lasting > 48 hours. All patients received enoxaparin at a dosage of 100 IU antiXa/kg twice daily before undergoing multiplane TEE. Previous informed consent and ethical committee authorization had been obtained. Twenty-four hours following TEE, in the absence of thrombi and/or spontaneous moderate/severe echocontrast in the atrial chambers, the patients underwent electrical cardioversion and were discharged within 24 hours of sinus rhythm restoration. These patients were prescribed enoxaparin at the indicated dosage twice daily until TEE, performed in an outpatients setting 7 days following cardioversion. In the absence of thrombi and/or atrial and/or left atrial appendage stunning, OAT was terminated. Enoxaparin was associated with OAT for the following 3 weeks if any of the following signs of stunning were present: A wave inferior to the normal value for age at transmitral

  5. Atrial therapies reduce atrial arrhythmia burden in defibrillator patients.

    Science.gov (United States)

    Friedman, P A; Dijkman, B; Warman, E N; Xia, H A; Mehra, R; Stanton, M S; Hammill, S C

    2001-08-28

    Approximately 25% of patients who receive an implantable cardioverter-defibrillator (ICD) to treat ventricular tachyarrhythmias have documented atrial tachyarrhythmias before implantation. This study assessed the ability of device-based prevention and termination therapies to reduce the burden of spontaneous atrial tachyarrhythmias. Patients with a standard indication for the implantation of an ICD and 2 episodes of atrial tachyarrhythmias in the preceding year received a dual-chamber ICD (Medtronic 7250 Jewel AF) that uses pacing and shock therapies for prevention and/or termination of atrial tachyarrhythmias. In a multicenter trial, patients were randomized to 3-month periods with atrial therapies "on" or "off" and subsequently crossed over. Analysis was performed on the 52 of 269 patients who had episodes of atrial tachyarrhythmia and had >/=30 days of follow-up with atrial therapies on and off. The atrial therapies resulted in a reduction of atrial tachyarrhythmia burden from a mean of 58.5 to 7.8 h/mo. A paired analysis (Wilcoxon signed-rank test) showed that the median difference in burden (1.1 h/mo) was highly significant (P=0.007). When the subgroup of 41 patients treated only with atrial pacing therapies was analyzed, the reduction in burden persisted (P=0.01). In this study, patients with a standard ICD indication and atrial tachyarrhythmias had a significant reduction in atrial tachyarrhythmia burden with use of atrial pacing and shock therapies.

  6. PR Interval Associated Genes, Atrial Remodeling and Rhythm Outcome of Catheter Ablation of Atrial Fibrillation—A Gene-Based Analysis of GWAS Data

    Directory of Open Access Journals (Sweden)

    Daniela Husser

    2017-12-01

    Full Text Available Background: PR interval prolongation has recently been shown to associate with advanced left atrial remodeling and atrial fibrillation (AF recurrence after catheter ablation. While different genome-wide association studies (GWAS have implicated 13 loci to associate with the PR interval as an AF endophenotype their subsequent associations with AF remodeling and response to catheter ablation are unknown. Here, we perform a gene-based analysis of GWAS data to test the hypothesis that PR interval candidate genes also associate with left atrial remodeling and arrhythmia recurrence following AF catheter ablation.Methods and Results: Samples from 660 patients with paroxysmal (n = 370 or persistent AF (n = 290 undergoing AF catheter ablation were genotyped for ~1,000,000 SNPs. Gene-based association was investigated using VEGAS (versatile gene-based association study. Among the 13 candidate genes, SLC8A1, MEIS1, ITGA9, SCN5A, and SOX5 associated with the PR interval. Of those, ITGA9 and SOX5 were significantly associated with left atrial low voltage areas and left atrial diameter and subsequently with AF recurrence after radiofrequency catheter ablation.Conclusion: This study suggests contributions of ITGA9 and SOX5 to AF remodeling expressed as PR interval prolongation, low voltage areas and left atrial dilatation and subsequently to response to catheter ablation. Future and larger studies are necessary to replicate and apply these findings with the aim of designing AF pathophysiology-based multi-locus risk scores.

  7. Association of the beta-1 adrenergic receptor carboxyl terminal variants with left ventricular hypertrophy among diabetic and non-diabetic survivors of acute myocardial infarction

    Directory of Open Access Journals (Sweden)

    Hakalahti Anna E

    2010-08-01

    Full Text Available Abstract Background The beta-1 adrenergic receptor (β1AR plays a fundamental role in the regulation of cardiovascular functions. It carries a nonsynonymous single nucleotide polymorphism in its carboxyl terminal tail (Arg389Gly, which has been shown to associate with various echocardiographic parameters linked to left ventricular hypertrophy (LVH. Diabetes mellitus (DM, on the other hand, represents a risk factor for LVH. We investigated the possible association between the Arg389Gly polymorphism and LVH among non-diabetic and diabetic acute myocardial infarction (AMI survivors. Methods The study population consisted of 452 AMI survivors, 20.6% of whom had diagnosed DM. Left ventricular parameters were measured with two-dimensional guided M-mode echocardiography 2-7 days after AMI, and the Arg389Gly polymorphism was determined using a polymerase chain reaction-restriction fragment length polymorphism assay. Results The Arg389 homozygotes in the whole study population had a significantly increased left ventricular mass index (LVMI when compared to the Gly389 carriers (either Gly389 homozygotes or Arg389/Gly389 heterozygotes [62.7 vs. 58.4, respectively (p = 0.023]. In particular, the Arg389 homozygotes displayed thicker diastolic interventricular septal (IVSd measures when compared to the Gly389 carriers [13.2 vs. 12.3 mm, respectively (p = 0.004]. When the euglycemic and diabetic patients were analyzed separately, the latter had significantly increased LVMI and diastolic left ventricular posterior wall (LVPWd values compared to the euglycemic patients [LVMI = 69.1 vs. 58.8 (p = 0.001 and LVPWd = 14.2 vs. 12.3 mm (p Conclusions The data suggest an association between the β1AR Arg389Gly polymorphism and LVH, particularly the septal hypertrophy. The Arg389 variant appears to confer a higher risk of developing LVH than the corresponding Gly389 variant among patients who have suffered AMI. This association cannot be considered to be universal

  8. High incidence of echocardiographic abnormalities of the interatrial septum in patients undergoing ablation for atrial fibrillation.

    Science.gov (United States)

    Schernthaner, Christiana; Danmayr, Franz; Daburger, Apollonia; Eichinger, Jörg; Hammerer, Matthias; Strohmer, Bernhard

    2013-04-01

    Atrial fibrosis or fatty deposition is known to increase the propensity for the development of atrial fibrillation (AF). Apart from the pulmonic veins, the interatrial septum (IAS) might play a role in the maintenance of AF. In contrast to left atrial anatomy and adjacent veins, the IAS cannot be visualized in detail with computed tomography. Thus, preprocedural transesophageal echocardiography (TEE) may provide important morphologic information beyond exclusion from atrial thrombi. The study comprised 108 consecutive patients (mean age 60 ± 11 years; 98 men). AF was paroxysmal in 91 (84%) and persistent in 17 (16%) patients. We investigated the morphological characteristics of the IAS by TEE in patients who underwent radiofrequency ablation of AF. The IAS was structurally abnormal in 46 (43%) patients, showing the following echocardiograhic findings: atrial septal hypermobility or aneurysm (n = 27) associated with a patent foramen ovale (PFO) (n = 11) or with a small atrial septal defect (ASD) (n = 2), a septal flap associated with a PFO or an ASD (n = 8), and an abnormally thickened IAS (n = 12). A thrombus in the left atrial appendage was discovered in only 2 (2%) patients. A structurally abnormal IAS was diagnosed in nearly half of the patients undergoing ablation therapy for AF. The information obtained by TEE is mandatory to exclude left atrial thrombi prior the ablation procedure. Moreover, detailed knowledge of morphologic characteristics of the IAS facilitates an optimized and safe performance of the transseptal puncture using long sheaths with large diameters. © 2012, Wiley Periodicals, Inc.

  9. Cerebral Pulsatility Index Is Elevated in Patients with Elevated Right Atrial Pressure.

    Science.gov (United States)

    Lahiri, Shouri; Schlick, Konrad H; Padrick, Matthew M; Rinsky, Brenda; Gonzalez, Nestor; Jones, Heather; Mayer, Stephan A; Lyden, Patrick D

    2018-01-01

    Extracerebral venous congestion can precipitate intracranial hypertension due to obstruction of cerebral blood outflow. Conditions that increase right atrial pressure, such as hypervolemia, are thought to increase resistance to jugular venous outflow and contribute to cerebro-venous congestion. Cerebral pulsatility index (CPI) is considered a surrogate marker of distal cerebrovascular resistance and is elevated with intracranial hypertension. Thus, we sought to test the hypothesis that elevated right atrial pressure is associated with increased CPI compared to normal right atrial pressure. We retrospectively reviewed 61 consecutive patients with subarachnoid hemorrhage. We calculated CPI from transcranial Doppler studies and correlated these with echocardiographic measures of right atrial pressure. CPIs were compared from patients with elevated and normal right atrial pressure. There was a significant difference between CPI obtained from all patients with elevated right atrial pressure compared to those with normal right atrial pressure (P right and left hemispheric CPI from patients with both elevated and normal right atrial pressure. Patients with elevated right atrial pressure had significantly higher CPI compared to patients with normal right atrial pressure. These findings suggest that cerebro-venous congestion due to impaired jugular venous outflow may increase distal cerebrovascular resistance as measured by CPI. Since elevated CPI is associated with poor outcome in numerous neurological conditions, future studies are needed to elucidate the significance of these results in other populations. Copyright © 2017 by the American Society of Neuroimaging.

  10. The mechanisms of atrial fibrillation in hyperthyroidism

    Directory of Open Access Journals (Sweden)

    Bielecka-Dabrowa Agata

    2009-04-01

    Full Text Available Abstract Atrial fibrillation (AF is a complex condition with several possible contributing factors. The rapid and irregular heartbeat produced by AF increases the risk of blood clot formation inside the heart. These clots may eventually become dislodged, causing embolism, stroke and other disorders. AF occurs in up to 15% of patients with hyperthyroidism compared to 4% of people in the general population and is more common in men and in patients with triiodothyronine (T3 toxicosis. The incidence of AF increases with advancing age. Also, subclinical hyperthyroidism is a risk factor associated with a 3-fold increase in development of AF. Thyrotoxicosis exerts marked influences on electrical impulse generation (chronotropic effect and conduction (dromotropic effect. Several potential mechanisms could be invoked for the effect of thyroid hormones on AF risk, including elevation of left atrial pressure secondary to increased left ventricular mass and impaired ventricular relaxation, ischemia resulting from increased resting heart rate, and increased atrial eopic activity. Reentry has been postulated as one of the main mechanisms leading to AF. AF is more likely if effective refractory periods are short and conduction is slow. Hyperthyroidism is associated with shortening of action potential duration which may also contribute to AF.

  11. Can contrast-enhanced multi-detector computed tomography replace transesophageal echocardiography for the detection of thrombogenic milieu and thrombi in the left atrial appendage. A prospective study with 124 patients; Kann die kontrastmittelverstaerkte Mehrzeilen-Computertomografie die transoesophageale Echokardiografie bei der Detektion von thrombogenem Milieu und Vorhofohrthromben ersetzen? Eine prospektive Studie mit 124 Patienten

    Energy Technology Data Exchange (ETDEWEB)

    Homsi, R.; Luetkens, J.A.; Schild, H.H.; Naehle, C.P. [Bonn Univ. (Germany). Dept. of Radiology; Nath, B. [SHG-KLliniken Voelklingen (Germany). Dept. of Medicine I - Cardiology; Schwab, J.O. [Bonn Univ. (Germany). Dept. of Medicine I - Cardiology

    2016-01-15

    To assess the diagnostic value of contrast-enhanced multi-detector computed tomography (MD-CT) for identifying patients with left atrial appendage (LAA) thrombus or circulatory stasis. 124 patients with a history of atrial fibrillation and/or cerebral ischemia (83 men, mean age 58.6 ± 12.4 years) and with a clinical indication for MD-CT of the heart and for transesophageal echocardiography (TEE) were included in the study. LAA thrombus or thrombogenic milieu was visually identified in TEE and MD-CT. In addition, MD-CT was analyzed quantitatively measuring the Hounsfield units (HU) of the left atrium (LA), the LAA and the ascending aorta (AA), and calculating the HU ratios LAA/AA (HU [LAA/AA]) und LAA/LA (HU [LAA/LA]). Sensitivity, specificity, negative predictive value (NPV) and positive predictive value (PPV) were calculated. The prevalence of a thrombus or thrombogenic milieu as assessed by TEE was 21.8 %. The HU ratio was lower in patients with thrombus or thrombogenic milieu (HU [LAA/AA]: 0.590 ± 0.248 vs. 0.909 ± 0.141; p < 0.001 und HU [LAA/LA] 0.689 ± 0.366 vs. 1.082 ± 0.228; p < 0.001). For the diagnosis of thrombus or a thrombogenic milieu, visual analysis yielded a sensitivity of 81.5 %, a specificity of 96.9 %, a PPV of 87.5 % and a NPV of 95.2 %. By combining visual and quantitative analysis with one criterion being positive, the specificity decreased to 91.8 %, the sensitivity to 77.8 %, the PPV to 72.4 %, and the NPV to 94.9 %. Visual analysis of the LAA in the evaluation of thrombus or thrombogenic milieu yields a high NPV of 95.1 % and may especially be useful to rule out LAA thrombi in patients with contraindications for TEE. Additional calculation of HU ratios did not improve the diagnostic performance of MD-CT.

  12. Surgical Treatment of Atrial Fibrillation in Patients with Rheumatic Valve Disease

    Directory of Open Access Journals (Sweden)

    Ernesto Koehler Chavez

    Full Text Available Abstract Objective: To assess heart rhythm and predictive factors associated with sinus rhythm after one year in patients with rheumatic valve disease undergoing concomitant surgical treatment of atrial fibrillation. Operative mortality, survival and occurrence of stroke after one year were also evaluated. Methods: Retrospective longitudinal observational study of 103 patients undergoing rheumatic mitral valve surgery and ablation of atrial fibrillation using uni- or bipolar radiofrequency between January 2013 and December 2014. Age, gender, functional class (NYHA, type of atrial fibrillation, EuroSCORE, duration of atrial fibrillation, stroke, left atrial size, left ventricular ejection fraction, cardiopulmonary bypass time, myocardial ischemia time and type of radiofrequency were investigated. Results: After one year, 66.3% of patients were in sinus rhythm. Sinus rhythm at hospital discharge, lower left atrial size in the preoperative period and bipolar radiofrequency were associated with a greater chance of sinus rhythm after one year. Operative mortality was 7.7%. Survival rate after one year was 92.3% and occurrence of stroke was 1%. Conclusion: Atrial fibrillation ablation surgery with surgical approach of rheumatic mitral valve resulted in 63.1% patients in sinus rhythm after one year. Discharge from hospital in sinus rhythm was a predictor of maintenance of this rhythm. Increased left atrium and use of unipolar radiofrequency were associated with lower chance of sinus rhythm. Operative mortality rate of 7.7% and survival and stroke-free survival contribute to excellent care results for this approach.

  13. Left ventricular dysfunction with reduced functional cardiac reserve in diabetic and non-diabetic LDL-receptor deficient apolipoprotein B100-only mice

    Directory of Open Access Journals (Sweden)

    Bosch Fatima

    2011-06-01

    Full Text Available Abstract Background Lack of suitable mouse models has hindered the studying of diabetic macrovascular complications. We examined the effects of type 2 diabetes on coronary artery disease and cardiac function in hypercholesterolemic low-density lipoprotein receptor-deficient apolipoprotein B100-only mice (LDLR-/-ApoB100/100. Methods and results 18-month-old LDLR-/-ApoB100/100 (n = 12, diabetic LDLR-/-ApoB100/100 mice overexpressing insulin-like growth factor-II (IGF-II in pancreatic beta cells (IGF-II/LDLR-/-ApoB100/100, n = 14 and age-matched C57Bl/6 mice (n = 15 were studied after three months of high-fat Western diet. Compared to LDLR-/-ApoB100/100 mice, diabetic IGF-II/LDLR-/-ApoB100/100 mice demonstrated more calcified atherosclerotic lesions in aorta. However, compensatory vascular enlargement was similar in both diabetic and non-diabetic mice with equal atherosclerosis (cross-sectional lesion area ~60% and consequently the lumen area was preserved. In coronary arteries, both hypercholesterolemic models showed significant stenosis (~80% despite positive remodeling. Echocardiography revealed severe left ventricular systolic dysfunction and anteroapical akinesia in both LDLR-/-ApoB100/100 and IGF-II/LDLR-/-ApoB100/100 mice. Myocardial scarring was not detected, cardiac reserve after dobutamine challenge was preserved and ultrasructural changes revealed ischemic yet viable myocardium, which together with coronary artery stenosis and slightly impaired myocardial perfusion suggest myocardial hibernation resulting from chronic hypoperfusion. Conclusions LDLR-/-ApoB100/100 mice develop significant coronary atherosclerosis, severe left ventricular dysfunction with preserved but diminished cardiac reserve and signs of chronic myocardial hibernation. However, the cardiac outcome is not worsened by type 2 diabetes, despite more advanced aortic atherosclerosis in diabetic animals.

  14. Tempol improves lipid profile and prevents left ventricular hypertrophy in LDL receptor gene knockout (LDLr-/-) mice on a high-fat diet.

    Science.gov (United States)

    Viana Gonçalves, Igor Cândido; Cerdeira, Cláudio Daniel; Poletti Camara, Eduardo; Dias Garcia, José Antônio; Ribeiro Pereira Lima Brigagão, Maísa; Bessa Veloso Silva, Roberta; Bitencourt Dos Santos, Gérsika

    2017-09-01

    Dyslipidemia is associated with increased risk of cardiovascular disease and atherosclerosis, and hence with high morbidity and mortality. This study investigated the effects of the nitroxide 4-hydroxy-2,2,6,6-tetramethylpiperidine 1-oxyl (Tempol) on lipid profile and cardiac morphology in low-density lipoprotein (LDL) receptor gene knockout (LDLr-/-) mice. Male LDLr-/- mice (three months old, approximately 22 g weight) were divided into the following groups: controls, including (1) standard chow (SC, n=8) and (2) high-fat diet (HFD, n=8); and treatment, including (3) standard chow + Tempol (SC+T, n=8) (30 mg/kg administered by gavage, once daily) and (4) high-fat diet + Tempol (HFD+T, n=8) (30 mg/kg). After 30 days of the diet/treatment, whole blood was collected for analysis of biochemical parameters (total cholesterol, triglycerides [TG], high-density lipoprotein [HDL], LDL, and very low-density lipoprotein [VLDL]). The heart was removed through thoracotomy and histological analysis of the left ventricle was performed. A significant increase in TG, LDL, and VLDL and marked left ventricular hypertrophy (LVH) were demonstrated in the HFD group relative to the SC group (p<0.05), while Tempol treatment (HFD+T group) significantly (p<0.05) prevented increases in the levels of these lipid profile markers and attenuated LVH compared with the HFD group. In this study, Tempol showed potential for the prevention of events related to serious diseases of the cardiovascular system. Copyright © 2017 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Effect of atrial preference pacing on reducing long-term burden of atrial fibrillation:a clinical study

    International Nuclear Information System (INIS)

    Xu Jianfeng; Chen Yueguang; Su Yangang; Zhang Dadong

    2010-01-01

    Objective: To evaluate the clinical effect of atrial preference pacing (APP) on the prevention of paroxysmal atrial fibrillation. Methods: Based on the type of implanted pacemaker, 46 patients with sick sinus syndrome and paroxysmal atrial fibrillation were divided into two groups. Dual-chamber pacemaker equipped with APP function was implanted in patients of group APP (n=21), while conventional dual-chamber pacemaker was implanted in patients of control group (n=25). The patients were followed up for six months, the maximum P wave duration (Pmax), the P wave dispersion (Pd), the structure of heart chambers, the data of automatic mode switch (AMS) and the total burden of atrial fibrillation were estimated,and the results were statistically analyzed and compared between two groups. Results: The basic clinical characteristics of two groups were comparable. After six months pacing, the difference in Pmax between two groups was of no significance (115.0 ± 10.1 ms vs 122.0 ± 11.0 ms, P > 0.05), while the increase of Pd in control group was more obvious than that in group APP (32.7 ± 4.2 ms vs 20.1 ± 5.3 ms, P 0.05), and also no remarkable difference in the left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV) and left ventricular ejection fraction (LVEF) could be found (P > 0.05). Moreover, no significant difference existed between two groups (P > 0.05). After six months pacing,in group APP the frequencies of AMS decreased more sharply (145 ± 37 times vs 327 ± 13 times, P < 0.05), the duration of AMS shortened more apparently (73 ± 15 hours vs 139 ± 28 hours, P < 0.05) and the total burden of atrial fibrillation was alleviated more obviously (13 ± 5% vs 28 ± 6%, P < 0.05) when compared to those in control group. Conclusion: Atrial preference pacing can coordinate the anisotropy of double atrial depolarization, reduce the frequencies of long-term paroxysmal atrial fibrillation, shorten the duration of atrial fibrillation

  16. Clinical Differences between Subtypes of Atrial Fibrillation and Flutter: Cross-Sectional Registry of 407 Patients

    Directory of Open Access Journals (Sweden)

    Eduardo Dytz Almeida

    2015-01-01

    Full Text Available Introduction: Atrial fibrillation and atrial flutter account for one third of hospitalizations due to arrhythmias, determining great social and economic impacts. In Brazil, data on hospital care of these patients is scarce. Objective: To investigate the arrhythmia subtype of atrial fibrillation and flutter patients in the emergency setting and compare the clinical profile, thromboembolic risk and anticoagulants use. Methods: Cross-sectional retrospective study, with data collection from medical records of every patient treated for atrial fibrillation and flutter in the emergency department of Instituto de Cardiologia do Rio Grande do Sul during the first trimester of 2012. Results: We included 407 patients (356 had atrial fibrillation and 51 had flutter. Patients with paroxysmal atrial fibrillation were in average 5 years younger than those with persistent atrial fibrillation. Compared to paroxysmal atrial fibrillation patients, those with persistent atrial fibrillation and flutter had larger atrial diameter (48.6 ± 7.2 vs. 47.2 ± 6.2 vs. 42.3 ± 6.4; p < 0.01 and lower left ventricular ejection fraction (66.8 ± 11 vs. 53.9 ± 17 vs. 57.4 ± 16; p < 0.01. The prevalence of stroke and heart failure was higher in persistent atrial fibrillation and flutter patients. Those with paroxysmal atrial fibrillation and flutter had higher prevalence of CHADS2 score of zero when compared to those with persistent atrial fibrillation (27.8% vs. 18% vs. 4.9%; p < 0.01. The prevalence of anticoagulation in patients with CHA2DS2-Vasc ≤ 2 was 40%. Conclusions: The population in our registry was similar in its comorbidities and demographic profile to those of North American and European registries. Despite the high thromboembolic risk, the use of anticoagulants was low, revealing difficulties for incorporating guideline recommendations. Public health strategies should be adopted in order to improve these rates.

  17. Atrial Fibrillation in Lusaka – Pathoaetiology, Pathophysiology and ...

    African Journals Online (AJOL)

    RICHY

    functional A-V blocks (see Fuster V et al ). Haemodynamic ... valve disease and left ventricular dysfunction, causes atrial ... to guide management that could reduce or eliminate the occurrence of ..... electromechanical function in AF leads to blood stasis. This, in ..... Initiation After Cardioversion Circulation.;104:802-. 809. 24.

  18. Risk Factors for Atrial Fibrillation

    NARCIS (Netherlands)

    B.P. Krijthe (Bouwe)

    2013-01-01

    textabstractAtrial fibrillation is a common cardiac arrhythmia that is characterized by rapid disorganized atrial electrical activity resulting in absence of atrial contractions. It is diagnosed on the basis of typical findings on an electrocardiogram (ECG). The characteristic ECG findings are

  19. Surgical removal of atrial septal defect occlusion device and mitral valve replacement in a 39-year-old female patient with infective endocarditis

    Directory of Open Access Journals (Sweden)

    A S Zotov

    2018-02-01

    Full Text Available Atrial septal defects represent the second most frequent congenital heart disease after ventricular septal defects. Transcatheter closure of an atrial septal defect is usually performed following strict indications on patients with significant left-to-right shunt. Infective endocarditis after transcatheter implantation of atrial septal defect occluder is an extremely rare complication. We report a case of infective endocarditis of the mitral valve (with severe mitral valve insufficiency in a 39-year-old female patient 13 years after transcatheter closure of an atrial septal defect. Complex prophylactic antibiotic coverage was performed prior to surgical intervention. Surgical removal of atrial septal defect occluder, mitral valve replacement, atrial septal defect closure and left atrial appendage resection were performed. Postoperative course was uneventful.

  20. Automatic detection and classification of human epicardial atrial unipolar electrograms

    International Nuclear Information System (INIS)

    Dubé, B; Vinet, A; Xiong, F; Yin, Y; LeBlanc, A-R; Pagé, P

    2009-01-01

    This paper describes an unsupervised signal processing method applied to three-channel unipolar electrograms recorded from human atria. These were obtained by epicardial wires sutured on the right and left atria after coronary artery bypass surgery. Atrial (A) and ventricular (V) activations had to be detected and identified on each channel, and gathered across the channels when belonging to the same global event. The algorithm was developed and optimized on a training set of 19 recordings of 5 min. It was assessed on twenty-seven 2 h recordings taken just before the onset of a prolonged atrial fibrillation for a total of 1593697 activations that were validated and classified as normal atrial or ventricular activations (A, V) and premature atrial or ventricular activations (PAA, PVA). 99.93% of the activations were detected, and amongst these, 99.89% of the A and 99.75% of the V activations were correctly labelled. In the subset of the 39705 PAA, 99.83% were detected and 99.3% were correctly classified as A. The false positive rate was 0.37%. In conclusion, a reliable fully automatic detection and classification algorithm was developed that can detect and discriminate A and V activations from atrial recordings. It can provide the time series needed to develop a monitoring system aiming to identify dynamic predictors of forthcoming cardiac events such as postoperative atrial fibrillation

  1. Toll/Interleukin-1 receptor member ST2 exhibits higher soluble levels in type 2 diabetes, especially when accompanied with left ventricular diastolic dysfunction

    Directory of Open Access Journals (Sweden)

    Fousteris Evangelos

    2011-11-01

    Full Text Available Abstract Background Soluble ST2, a member of the of the Toll/IL-1 superfamily, is a novel biomarker with exceptional predictive value in heart failure and myocardial infarction- related mortality as well as in acute dyspneic states. Soluble ST2 is considered a decoy receptor of IL 33 that blocks the protective effects of the cytokine in atherosclerosis and cardiac remodeling. In the present study we investigated the differences in the levels of soluble ST2, BNP and hs-CRP between healthy controls and patients with type 2 diabetes with and without left ventricular diastolic dysfunction. A secondary aim was to investigate correlations between sST2 and other biomarkers of type 2 diabetes, such as HbA1c. Methods 158 volunteers were recruited and underwent a complete Doppler-echocardiographic evaluation of both systolic & diastolic cardiac function. All subjects with ejection fraction Results Patients with type 2 diabetes with (p Conclusions Patients with type 2 diabetes exhibit higher sST2 levels compared to healthy controls. The presence of LVDD in patients with type 2 diabetes is associated with even higher sST2 levels. A significant correlation between glycemic control and sST2 levels was also revealed.

  2. Recurrent atrial myxoma.

    Science.gov (United States)

    Macarie, C; Stoica, E; Chioncel, O; Carp, A; Gherghiceanu, D; Stiru, O; Zarma, L; Herlea, V

    2004-01-01

    We have chosen this case of sporadic atrial myxoma for our presentation because it had a particular evolution, with recurrence at 8 years after surgical excision (echocardiography was performed every year) and a particular diagnostic means - at echocardiographic follow-up, the patient being asymptomatic. This presentation, together with a review of literature included in the article, emphasizes the importance of a careful postoperative follow-up of the patients and the existence of some particular aspects of the evolution and symptomatology of recurrent atrial myxoma.

  3. Thyrotoxic atrial fibrillation.

    Science.gov (United States)

    Parmar, Malvinder S

    2005-01-04

    Atrial fibrillation is the most common cardiac complication of hyperthyroidism and occurs in 15% of patients with hyperthyroidism. It is associated with a higher risk of thromboembolism that often involves the central nervous system. Oral anticoagulation is important in the majority of these patients to prevent thromboembolic complications. These patients require adjustment in the dose of various rate-controlling agents because of increased clearance associated with hyperthyroidism and a decrease in warfarin dosage because of increased clearance of vitamin K-dependent clotting factors. The management of thyrotoxic atrial fibrillation is summarized in this clinical review.

  4. Atrial natriuretic peptide in patients with heart failure and chronic atrial fibrillation : Role of duration of at atrial fibrillation

    NARCIS (Netherlands)

    Van Den Berg, MP; Crijns, HJGM; Van Veldhuisen, DJ; Van Gelder, IC; De Kam, PJ; Lie, KI

    The purpose of this study was to analyze the determinants of atrial natriuretic peptide level in patients with congestive heart failure and atrial fibrillation. In particular, the duration of atrial fibrillation was analyzed because atrial fibrillation per se might have a specific effect on atrial

  5. [Recurrent right atrial thrombus in a patient with atrial fibrillation and heart failure].

    Science.gov (United States)

    Elikowski, Waldemar; Wróblewski, Dariusz; Małek-Elikowska, Małgorzata; Mazurek, Andrzej; Foremska-Iciek, Joanna; Łazowski, Stanisław

    2015-11-01

    Atrial fibrillation and heart failure are factors predisposing to locally formed intracardiac thrombosis, which is usually localized in left-sided chambers. A case report. The authors present a case of a 50-year-old male with permanent atrial fibrillation and dilated cardiomyopathy in whom recurrent right atrial thrombus was observed. Initially, the lesion was detected in echocardiography while he was hospitalized due to extensive right-sided pneumonia. The thrombus was successfully treated with heparin, followed by warfarin. Even though the patient continued warfarin use properly, there was recurrence of the thrombus two years later during a new episode of heart failure exacerbation. Because the thrombus was resistant to intensified anticoagulation, cardiac surgery was needed. A large (30 x 25 mm) pedunculated thrombus, as well as two smaller ones (each of 10 x 10 mm) attached closely to the atrial wall and previously not detected either by echocardiography or by magnetic resonance imaging, were excited. A partially organized pattern of the thrombi in histological examination can explain lack of anticoagulation effectiveness. © 2015 MEDPRESS.

  6. New Procedure for Treatment of Atrial Fibrillation in Patients with Valvular Heart Disease

    Directory of Open Access Journals (Sweden)

    Naser Safaie

    2010-10-01

    Full Text Available Patients with valvular heart disease suffer from atrial fibrillation for more than 12 months after valve surgery and have a low probability of remaining in sinus rhythm. We performed an intra-operative procedure similar to surgical maze ІІІ procedure for conversion of this arrhythmia to sinus rhythm. We did this study to evaluate the efficacy of this procedure to restore the sinus rhythm in patients with valvular heart disease. 28 patients with valvular heart disease and chronic persistent atrial fibrillation underwent different combinations of valve surgery and concomitant reduction of left and right atrial size and resection of both atrial auricles in Shahid Madani cardiothoracic center from September 2004 to October 2008. The procedure for atrial fibrillation treatment was performed with cardiopulmonary bypass and after mitral valve replacement. There was one in-hospital death postoperatively because of respiratory failure, but no other complication till 6 months after the operation. Out of 28 patients, 23 were in sinus rhythm one week after the operation, one patient had junctional rhythm after the operation that restored to sinus rhythm and 4 patients had persistent atrial fibrillation. During the 12-month follow up, atrial fibrillation was corrected in 82.14%. Doppler echocardiography in these patients with sinus rhythm demonstrated good atrial contractility. This procedure on both atria is effective and less invasive than the original maze procedure to eliminate the atrial fibrillation, and can be performed in patients with valvular heart disease without increasing the risk of operation.

  7. New Procedure for Treatment of Atrial Fibrillation in Patients with Valvular Heart Disease

    Directory of Open Access Journals (Sweden)

    Naser Safaie

    2010-09-01

    Full Text Available "nPatients with valvular heart disease suffer from atrial fibrillation for more than 12 months after valve surgery and have a low probability of remaining in sinus rhythm. We performed an intra-operative procedure similar to surgical maze ІІІ procedure for conversion of this arrhythmia to sinus rhythm. We did this study to evaluate the efficacy of this procedure to restore the sinus rhythm in patients with valvular heart disease. 28 patients with valvular heart disease and chronic persistent atrial fibrillation underwent different combinations of valve surgery and concomitant reduction of left and right atrial size and resection of both atrial auricles in Shahid Madani cardiothoracic center from September 2004 to October 2008. The procedure for atrial fibrillation treatment was performed with cardiopulmonary bypass and after mitral valve replacement. There was one in-hospital death postoperatively because of respiratory failure, but no other complication till 6 months after the operation. Out of 28 patients, 23 were in sinus rhythm one week after the operation, one patient had junctional rhythm after the operation that restored to sinus rhythm and 4 patients had persistent atrial fibrillation. During the 12-month follow up, atrial fibrillation was corrected in 82.14%. Doppler echocardiography in these patients with sinus rhythm demonstrated good atrial contractility. This procedure on both atria is effective and less invasive than the original maze procedure to eliminate the atrial fibrillation, and can be performed in patients with valvular heart disease without increasing the risk of operation.

  8. [Echocardiographic factors predictive of restoration and maintenance of sinus rhythm after reduction of atrial fibrillation].

    Science.gov (United States)

    Ben Khalfallah, A; Sanaa, I

    2007-09-01

    Atrial fibrillation (AF) is the most common cardiac arrhythmia. While the arrhythmia was initially thought to be little more than a nuisance, it is now clear that AF has a significant negative impact on quality of life and a corresponding increase in both morbidity and mortality. The aim of this study was to identify Doppler echographic patterns that allow prediction of atrial fibrillation reduction and maintenance of sinus rhythm within 12 months. One hundred and thirty patients having permanent atrial fibrillation, recent (51) or chronic (79) are included in the study, excepting those with valvular heart disease or thyroid dysfunction. The mean age was 63.5 +/- 11.3 years. Both transthoracic and transoesophageal echocardiography was performed using a Philips SONOS 5500 Echograph, before cardioversion. Were studied: end diastolic and systolic left ventricular diameters, left ventricular ejectionnal fraction, left atrial area (LAA), left atrial diameter, left atrial appendage area and peak emptying velocities of the left atrial appendage (PeV). Sinus rhythm was re-established in 102 patients (44 having recent and 58 chronic atrial fibrillation). Sinus rhythm was maintained for 12 months in 79 patients. Within the echographic parameters studied, the left atrial area (LAA) and peak emptying velocities of left atrial appendage (PeV) before cardioversion were the best predictors of restoration of sinus rhythm. On monovariate analysis, SOG is significantly lower and PicV is significantly higher in patients whose sinus rhythm had been restored in comparison with those with permanent atrial fibrillation. (Mean SOG: 27.7 +/- 7.62 vs. 34 +/- 7,6 cm2, ppredict on mono and multivariate analysis (p=0.05, OR=0.5, IC=0.36 à 3.56), re-establishing of sinus rhythm whereas in patients with chronic atrial fibrillation, peak emptying velocity of left atrial appendage predict better re-establishing of sinus rhythm (p=0.04, OR=1.29, IC=0.12 à 4.23). The threshold values of LAA and Pe

  9. Biomarkers of Atrial Cardiopathy and Atrial Fibrillation Detection on Mobile Outpatient Continuous Telemetry After Embolic Stroke of Undetermined Source.

    Science.gov (United States)

    Sebasigari, Denise; Merkler, Alexander; Guo, Yang; Gialdini, Gino; Kummer, Benjamin; Hemendinger, Morgan; Song, Christopher; Chu, Antony; Cutting, Shawna; Silver, Brian; Elkind, Mitchell S V; Kamel, Hooman; Furie, Karen L; Yaghi, Shadi

    2017-06-01

    Biomarkers of atrial dysfunction or "cardiopathy" are associated with embolic stroke risk. However, it is unclear if this risk is mediated by undiagnosed paroxysmal atrial fibrillation or flutter (AF). We aim to determine whether atrial cardiopathy biomarkers predict AF on continuous heart-rhythm monitoring after embolic stroke of undetermined source (ESUS). This was a single-center retrospective study including all patients with ESUS undergoing 30 days of ambulatory heart-rhythm monitoring to look for AF between January 1, 2013 and December 31, 2015. We reviewed medical records for clinical, radiographic, and cardiac variables. The primary outcome was a new diagnosis of AF detected during heart-rhythm monitoring. The primary predictors were atrial biomarkers: left atrial diameter on echocardiography, P-wave terminal force in electrocardiogram (ECG) lead V1, and P wave - R wave (PR) interval on ECG. A multiple logistic regression model was used to assess the relationship between atrial biomarkers and AF detection. Among 196 eligible patients, 23 (11.7%) were diagnosed with AF. In unadjusted analyses, patients with AF were older (72.4 years versus 61.4 years, P atrial diameter (39.2 mm versus 35.7 mm, P = .03). In a multivariable model, the only predictor of AF was age ≥ 60 years (odds ratio, 3.0; 95% CI, 1.06-8.5; P = .04). Atrial biomarkers were weakly associated with AF after ESUS. This suggests that previously reported associations between these markers and stroke may reflect independent cardiac pathways leading to stroke. Prospective studies are needed to investigate these mechanisms. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  10. Noninvasive evaluation of reverse atrial remodeling after catheter ablation of atrial fibrillation by P wave dispersion.

    Science.gov (United States)

    Fujimoto, Yuhi; Yodogawa, Kenji; Takahashi, Kenta; Tsuboi, Ippei; Hayashi, Hiroshi; Uetake, Shunsuke; Iwasaki, Yu-Ki; Hayashi, Meiso; Miyauchi, Yasushi; Shimizu, Wataru

    2017-11-01

    Atrial fibrillation (AF) itself creates structural and electrophysiological changes such as atrial enlargement, shortening of refractory period and decrease in conduction velocity, called "atrial remodeling", promoting its persistence. Although the remodeling process is considered to be reversible, it has not been elucidated in detail. The aim of this study was to assess the feasibility of P wave dispersion in the assessment of reverse atrial remodeling following catheter ablation of AF. Consecutive 126 patients (88 males, age 63.0 ± 10.4 years) who underwent catheter ablation for paroxysmal AF were investigated. P wave dispersion was calculated from the 12 lead ECG before, 1 day, 1 month, 3 months and 6 months after the procedure. Left atrial diameter (LAD), left atrial volume index (LAVI), left ventricular ejection fraction (LVEF), transmitral flow velocity waveform (E/A), and tissue Doppler (E/e') on echocardiography, plasma B-type natriuretic peptide (BNP) concentrations, serum creatinine, and estimated glomerular filtration rate (eGFR) were also measured. Of all patients, 103 subjects remained free of AF for 1 year follow-up. In these patients, P wave dispersion was not changed 1 day and 1 month after the procedure. However, it was significantly decreased at 3 and 6 months (50.1 ± 14.8 to 45.4 ± 14.4 ms, p < 0.05, 45.2 ± 9.9 ms, p < 0.05, respectively). Plasma BNP concentrations, LAD and LAVI were decreased (81.1 ± 103.8 to 44.8 ± 38.3 pg/mL, p < 0.05, 38.2 ± 5.7 to 35.9 ± 5.6 mm, p < 0.05, 33.3 ± 14.2 to 29.3 ± 12.3 mL/m 2 , p < 0.05) at 6 months after the procedure. There were no significant changes in LVEF, E/A, E/e', serum creatinine, and eGFR during the follow up period. P wave dispersion was decreased at 3 and 6 months after catheter ablation in patients without recurrence of AF. P wave dispersion is useful for assessment of reverse remodeling after catheter ablation of AF.

  11. Left ventricular systolic function in sickle cell anaemia: an ...

    African Journals Online (AJOL)

    42) and 24.17 ± 4.39 ... Aortic root diameter (Ao), left atrial dimension (LAD), left ventricu- ... Key: *Statistically significant, a= Chi-square, SCA= sickle cell anaemia, SD= standard deviation. ..... of fluctuations in response to changes in sympathetic.

  12. Increased amount of atrial fibrosis in patients with atrial fibrillation secondary to mitral valve disease

    NARCIS (Netherlands)

    Geuzebroek, Guillaume S. C.; van Amersfoorth, Shirley C. M.; Hoogendijk, Mark G.; Kelder, Johannes C.; van Hemel, Norbert M.; de Bakker, Jacques M. T.; Coronel, Ruben

    2012-01-01

    Objective: Atrial fibrosis is related to atrial fibrillation but may differ in patients with mitral valve disease or lone atrial fibrillation. Therefore, we studied atrial fibrosis in patients with atrial fibrillation + mitral