  1. Green roofs and the LEED green building rating system

    Energy Technology Data Exchange (ETDEWEB)

    Kula, R. [Sustainable Solutions Inc., Wagoner, OK (United States)

    2005-07-01

    The sustainable building industry is becoming increasingly aware of the host of public and private benefits that green roofs can provide in built environments. In dense urban environments, green roofs function to reduce stormwater runoff, urban heat island effects, and particulate matter (PM) pollution. The emerging green roof industry is now poised to support the efforts of green building networks in North America. This paper discussed the general benefits of green roofs, and their recognition within the Leadership in Energy and Environmental Design (LEED) Green Building Rating System. A case study of Mountain Equipment Co-op's Winnipeg site was presented. The building's green roof was directly responsible for earning 5 credits and contributing to the achievement of an additional 2 credits under the LEEDS certification process. Credits were earned for reduced site disturbance; landscape design to reduce heat islands; and water efficiency. The green roof at the site provided the vast majority of the building's cooling needs through an evaporative cooling trough. A photovoltaic pump was used to feed the building's irrigation system, as well as to pump ground water through cooling valances. It was concluded that the rise of sustainable building practices and the LEED Green Building Rating System will revolutionize the way new buildings are constructed.

  2. Critical review of LEED system for rating sustainability of architecture of commercial interiors

    Directory of Open Access Journals (Sweden)

    Stevanović Sanja

    2010-01-01

    Full Text Available The LEED rating system for sustainability of architecture has gained large marketing potential in USA and became one of main ways American builders are attacking ecological challenges. In this paper the LEED rating system for commercial interiors is critically reviewed, pointing out its positive - focus on integrated design process - and negative impacts - low thresholds for highest ratings and tendency to gain LEED rating with projects that hardly pass the thresholds, largely neglecting the principles of energy efficiency. Based on a few prominent LEED platinum examples, the beginnings of a LEED style of designing interiors in historical landmark buildings are pointed out as well.

  3. Impact of different LEED versions for green building certification and energy efficiency rating system: A Multifamily Midrise case study

    International Nuclear Information System (INIS)

    Rastogi, Ankush; Choi, Jun-Ki; Hong, Taehoon; Lee, Minhyun

    2017-01-01

    Highlights: •Energy consumption change from applying different LEED versions were investigated. •Four analysis scenarios were compared using different versions of ASHRAE Standard. •A case study of a mid-rise multi-family building was conducted using energy simulation. •Residential buildings could benefit from LEED v4 due to the low prerequisite. •Renovation buildings are highly incentivized regardless of LEED version used. -- Abstract: Various versions of the Leadership in Energy and Environmental Design (LEED ® ) have been introduced with the addition of more stringent sustainability parameters and credit scoring schemes over the past decade. Such changes in LEED versions strongly affect the energy performance and LEED scores of the target building in the LEED certification process. Therefore, to validate and improve the current LEED version, it is crucial to investigate and compare the impact of different LEED versions on the building energy performance and scoring scheme. However, researches comparing the sustainability metrics for mid-rise multi-family buildings are rare. Therefore, this paper investigates the potential changes in the energy performance resulted from applying different LEED versions (i.e., LEED v3 and v4) for the Energy and Atmosphere (EA) category. Towards this end, a case study was carried out with energy modeling and simulation using TRACE 700 to compare the changes in the energy performance of four analysis scenarios applied to an existing mid-rise multi-family building located in Ohio. Results showed notable changes in LEED points when different versions of LEED using different ASHRAE Standards (i.e., ASHRAE Standards 90.1-2007 and 90.1-2010) are applied for the building energy analysis. In particular, mid-rise multi-family buildings could benefit from LEED v4 in terms of LEED credits as the prerequisite for the minimum energy performance improvement in EA category became significantly lenient compared to LEED v3. On the

  4. Assessing and Developing the Application of LEED Green Building Rating System as a Sustainable Project Management and Market Tool in the Italian Context

    Directory of Open Access Journals (Sweden)

    Walaa S. E. Ismaee

    2016-07-01

    Full Text Available The paper discusses the recent introduction of the LEED system to the Italian context in order to assess its role to promote sustainable building process in the Italian context, pointing out its potentials on one hand as well as their gaps and limitations on the other hand, and suggests means for its future development. The study discusses the application of LEED as a ‘Sustainable Project management tool’ to guide sustainable building performance. This requires investigating the following: its structure, tools, assessment criteria along with its benchmarks and references. It also discusses the application of LEED as a ‘Sustainable building Certification and market tool’. This investigates the role and value of the LEED certification in the Italian Green market. The research method is comprised of three parts. The first part is a comparative analysis of LEED categories against Italian national initiatives for sustainability. The comparison showed that most LEED categories are already mandated by national norms and directives but they may differ in their stringency creating some areas of precedence of LEED system or drawbacks. This streamlines the adaptation process of LEED system to the Italian context. The second part investigates LEED projects’ market analysis. The result showed that the shift towards a sustainable building process is occurring slowly and on a vertical scale focusing on some building sectors rather than others. Its market diffusion in the Italian context faces challenges regarding the insufficient availability of green materials and products satisfying its requirements, as well as high soft cost of sustainability tests and expertise required. The Third part presents a practical review-citing the methodology and results of a survey conducted by the researchers in mid-2012. It is composed of a web-based questionnaire and interviews among a sample of LEED professionals in Italy. The result shows that LEED systems needs

  5. Introducing comparative analysis to the LEED system: A case forrational and regional application

    Energy Technology Data Exchange (ETDEWEB)

    Eijadi, David; Vaidya, Prausad; Reinertsen, James; Kumar, Satish

    2002-06-01

    The LEED(TM) system awards points for prescriptive andperformance based environmental strategies; rightly giving more weight todecisions affecting building operations, since environmental impacts overthe life of a building exceed the one-time environmental impacts affectedby the building s construction. The environmental benefits of LEED(TM)strategies are considered implicit and the point system is not a metricof environmental performance. Thus, guideline strategies that achieve thesame points may not have analogous environmental performance. This paperdraws from our LEED(TM) project experience as certified consultants to anumber of design teams. We applied analysis to those experiences andargue that -The relative environmental value of the same LEED(TM)strategy may vary by geographical region and by building type. -Scoringsuccessive LEED(TM) points beyond a 'standard practice design'significantly increases design effort and capital costs for construction.-Without comparative analysis of the costs of alternate LEED(TM)strategies and their corresponding environmental benefit, designers willnot necessarily invest capital in strategies that most profoundlyminimize the environmental impacts of a building. -For design teams andowners interested in the least expensive LEED(TM) certification, gamingthe point system could drive investment away from sound environmentalperformance strategies such as energy efficiency. Using these arguments,this paper makes a case to enhance the LEED(TM) system by -CategorizingLEED(TM) strategies by their direct or indirect value towardsEnvironmental Benefit, Healthy Buildings (Places), and Profitability.-Reformulating prescriptive requirements into performance basedrequirements wherever possible. -Customizing LEED(TM) guidelines byregion.

  6. The association between the geography of fast food outlets and childhood obesity rates in Leeds, UK.

    Science.gov (United States)

    Fraser, Lorna K; Edwards, Kimberley L

    2010-11-01

    To analyse the association between childhood overweight and obesity and the density and proximity of fast food outlets in relation to the child's residential postcode. This was an observational study using individual level height/weight data and geographic information systems methodology. Leeds in West Yorkshire, UK. This area consists of 476 lower super-output areas. Children aged 3-14 years who lived within the Leeds metropolitan boundaries (n=33,594). The number of fast food outlets per area and the distance to the nearest fast food outlet from the child's home address. The weight status of the child: overweight, obese or neither. 27.1% of the children were overweight or obese with 12.6% classified as obese. There is a significant positive correlation (pfood outlets and higher deprivation. A higher density of fast food outlets was significantly associated (p=0.02) with the child being obese (or overweight/obese) in the generalised estimating equation model which also included sex, age and deprivation. No significant association between distance to the nearest fast food outlet and overweight or obese status was found. There is a positive relationship between the density of fast food outlets per area and the obesity status of children in Leeds. There is also a significant association between fast food outlet density and areas of higher deprivation. Copyright © 2010 Elsevier Ltd. All rights reserved.

  7. Federal Participation in LEED in 2005

    Energy Technology Data Exchange (ETDEWEB)

    Payne, Christopher; Dyer, Beverly

    2005-11-01

    The federal government is an active participant in promotingsustainable design, construction and operations and in the use of USGBC'sLeadership in Energy and Environmental Design (LEED) Green BuildingRating System. This paper presents an overview of sustainableconstruction activities in the federal sector in 2005.

  8. Mining Association Rules Between Credits in the Leadership in Energy and Environmental Design for New Construction (LEED-NC) Green Building Assessment System

    National Research Council Canada - National Science Library

    Thomas, Benjamin J

    2008-01-01

    The Leadership in Energy and Environmental Design (LEED) Building Assessment System is a performance-based tool for determining the environmental impact of a facility from the whole-building perspective...

  9. The use of Leeds Test Objects in the assessment of the performance of radiological imaging systems: an introduction

    International Nuclear Information System (INIS)

    Cowen, A.R.

    1986-01-01

    Over the preceding decade the Leeds Radiological Imaging Group have developed a range of test objects with which to assess the performance of radiological imaging systems. The types of imaging equipment which can be assessed include X-ray image intensifier television systems, small-format 100mm/105mm fluorography systems and radiographic screen-film combinations. We have recently extended our interest to the evaluation of digital radiological imaging equipment including digital subtraction fluorography and digital (greyscale) radiographic imaging systems. These test objects were initially developed for the purpose of evaluating imaging performance under laboratory conditions but they have also proved useful under field (clinical) conditions. (author)

  10. LEED (Low Energy Electron Diffraction)

    International Nuclear Information System (INIS)

    Aberdam, M.

    1973-01-01

    The various types of systems studied by LEED, and for which the geometry of diffraction patterns is exploited, are reviewed, intensity profiles being another source of information. Two representative approaches of the scattering phenomenon are examined; the band structure theory and the T matrix approach [fr

  11. University Leadership in Energy and Environmental Design: How Postsecondary Institutions Use the LEEDRTM Green Building Rating System

    Science.gov (United States)

    Chance, Shannon Massie

    2010-01-01

    This descriptive, exploratory study focused on how institutions of higher education have used the United States Green Building Council's (USGBC) Leadership in Energy and Environmental Design (LEED[R]) Green Building Rating system. It employed statistical methods to assess which types of universities have used LEED, what ratings they earned, and…

  12. The data acquisition system for the Leeds Infirmary MWPC X-ray imaging detector

    International Nuclear Information System (INIS)

    Quinton, S.; Gibbings, D.; Jones, D.; Norton, H.

    1979-10-01

    An electronic system is described which is designed to acquire and process data from a MWPC X-ray imaging detector. Two dimensional information from the chamber is obtained by using cathode plane delay-line readout. A single crate CAMAC assembly is used as the chamber-computer interface. The use of control source units for the delay line scalers and TV display driver functions together with an intermediate memory in the crate allows input data rates up to 1MHz and TV display facilities without constant computer refreshing. (author)

  13. Test objects for evaluating the performance of radiological imaging systems. Leeds radiological test objects

    International Nuclear Information System (INIS)

    Cowen, A.R.; Clarke, O.F.; Haywood, J.M.; Parker, R.P.

    1985-01-01

    A range of test objects has been developed to assess the imaging performance of conventional and digital radiological imaging systems. These test objects have arisen as a result of involvement in both the laboratory evaluation of radiological imaging systems and the routine maintenance of such equipment in a large diagnostic radiology department. The philosophy behind the design and application of the test objects is briefly described. Particular attention is paid to the advantages of using the threshold-contrast detail-detectability technique to assess overall imaging performance. The great importance of ensuring optimum imaging performance prior to clinical acceptance is stressed. A strategy for implementing the test objects in a clinical department is present. The diagnostic information content of the clinical images which result measures the success of the quality control procedure adopted. (author)

  14. Mining Association Rules Between Credits in the Leadership in Energy and Environmental Design for New Construction (LEED-NC) Green Building Assessment System

    National Research Council Canada - National Science Library

    Thomas, Benjamin J

    2008-01-01

    .... Taking this vision into account, the individual credits that comprise LEED are designed to reward design teams for employing sustainable design strategies that reduce the total environmental impact...

  15. Regional Variations of Credits Obtained by LEED 2009 Certified Green Buildings—A Country Level Analysis

    Directory of Open Access Journals (Sweden)

    Peng Wu

    2017-12-01

    Full Text Available Leadership in Energy and Environmental Design (LEED is one of the most widely recognized green building rating systems. With more than 20% of the projects certified in non-United States (US countries, LEED’s global impact has been increasing and it is critically important for developers and regulatory authorities to understand LEED’s performance at the country level to facilitate global implementation. This study therefore aims to investigate the credit achievement pattern of LEED 2009, which is one of the well-developed versions of LEED, by using 4021 certified projects in the US, China, Turkey, and Brazil. The results show that significant differences can be identified on most rating categories, including sustainable sites, water efficiency, energy and atmosphere, indoor environmental quality, and innovation in design. Using a post hoc analysis, country-specific credit allocation patterns are also identified to help developers to understand existing country-specific green building practices. In addition, it is also found that there is unbalanced achievement of regional priority credits. The study offers a useful reference and benchmark for international developers and contractors to understand the regional variations of LEED 2009 and for regulatory authorities, such as the U.S. Green Building Council, to improve the rating system, especially on designing regional priority credits.

  16. Leeds under a cloud

    International Nuclear Information System (INIS)

    1988-01-01

    Before 26 April 1986 few people in the west had heard of Chernobyl. Then Chernobyl experienced the world's worst nuclear power station accident. In the wake of the disaster radioactivity fell on Britain and much of Europe. There was confusion and rumour on the television, in the papers and amongst ordinary people. What would the effect of the Chernobyl accident be? Was it safe to go out of doors? Was it safe to eat fresh vegetables? What was a safe level of radiation? What was a becquerel, a milliSievert or any of the other scientific terms with which we were bombarded by scientists and other experts? This booklet sets out to help answer these questions by looking at a hypothetical disaster at the nuclear power station at Heysham, near Morecambe in Lancashire. Using this scenario it shows what the worst consequences of a nuclear accident might be for the citizens of Leeds. It also explains in a straightforward way the meaning of many technical terms which will help you to understand the advice and comments of experts and to make your own judgement of what they say. (author)

  17. Reliability of contemporary data-acquisition techniques for LEED analysis

    International Nuclear Information System (INIS)

    Noonan, J.R.; Davis, H.L.

    1980-10-01

    It is becoming clear that one of the principal limitations in LEED structure analysis is the quality of the experimental I-V profiles. This limitation is discussed, and data acquisition procedures described, which for simple systems, seem to enhance the quality of agreement between the results of theoretical model calculations and experimental LEED spectra. By employing such procedures to obtain data from Cu(100), excellent agreement between computed and measured profiles has been achieved. 7 figures

  18. A study of the effects of computer animation on college students’ learning of Leadership in Energy and Environmental Design - LEED

    Directory of Open Access Journals (Sweden)

    Razieh Nilforooshan

    2013-10-01

    Full Text Available This paper presents ongoing research aimed at investigating the efficacy of computer animations in improving college students’ learning of building sustainability concepts and practices. The use of animations in educational contexts is not new, however scientific evidence that supports their effectiveness as educational materials is still limited. This paper reports an experiment that explored the impact of an educational digital animation, called “LEED-ERS”, on college students’ learning of Leadership in Energy and Environmental Design (LEED rating system. Specifically, the animation focused on the LEED category of Sustainable Site. Results of a study with 68 students show that viewing the animation led to an increase in subjects’ declarative knowledge by 15%. Compared to traditional learning methods (e.g. reading assignments with static images, viewing the animation led to significantly higher declarative knowledge gains.

  19. Designing healthy communities: A walkability analysis of LEED-ND

    Directory of Open Access Journals (Sweden)

    Adriana A. Zuniga-Teran

    2016-12-01

    Full Text Available Prevailing city design in many countries has created sedentary societies that depend on automobile use. Consequently, architects, urban designers, and land planners have developed new urban design theories, which have been incorporated into the Leadership in Energy and Environmental Design for Neighborhood Development (LEED-ND certification system. The LEED-ND includes design elements that improve human well-being by facilitating walking and biking, a concept known as walkability. Despite these positive developments, relevant research findings from other fields of study have not been fully integrated into the LEED-ND. According to Zuniga-Teran (2015, relevant walkability research findings from multiple disciplines were organized into a walkability framework (WF that organizes design elements related to physical activity into nine categories, namely, connectivity, land use, density, traffic safety, surveillance, parking, experience, greenspace, and community. In this study, we analyze walkability in the LEED-ND through the lens of the nine WF categories. Through quantitative and qualitative analyses, we identify gaps and strengths in the LEED-ND and propose potential enhancements to this certification system that reflects what is known about enhancing walkability more comprehensively through neighborhood design analysis. This work seeks to facilitate the translation of research into practice, which can ultimately lead to more active and healthier societies.

  20. Application of a LEED apparatus provided with a lens to the study of vicinal surfaces

    International Nuclear Information System (INIS)

    Laydevant, Louis; Dupuy, J.C.

    1979-01-01

    Steps presence on vicinal surfaces changes the low energy electron difraction (LEED) pattern: a system of regulary spaced steps is causing some spots to be splitted. Using a high voltage LEED apparatus allows an easy explanation of the patterns: the spot position does not depend about energy and so some cristallographic parameters can be easily measured [fr

  1. Advances on surface structural determination by LEED

    International Nuclear Information System (INIS)

    Soares, Edmar A; De Carvalho, Vagner E; De Castilho, Caio M C

    2011-01-01

    In the last 40 years, low energy electron diffraction (LEED) has proved to be the most reliable quantitative technique for surface structural determination. In this review, recent developments related to the theory that gives support to LEED structural determination are discussed under a critical analysis of the main theoretical approximation-the muffin-tin calculation. The search methodologies aimed at identifying the best matches between theoretical and experimental intensity versus voltage curves are also considered, with the most recent procedures being reviewed in detail. (topical review)

  2. Assessing Sustainability in Developing Country Contexts: The Applicability of Green Building Rating Systems to Building Design and Construction in Madagascar and Tanzania

    OpenAIRE

    Ozolins, Peter Charles

    2010-01-01

    Buildings have significant and complex impacts both in their construction and in their use. Green building rating systems have been developed and promoted in more economically-advanced countries to offer guidelines to reduce negative impacts and to promote sustainable practices of building construction and operations. The green building rating system called Leadership in Energy and Environmental Design (LEED), established in 1995 by the U.S. Green Building Council, is increasingly accepted as...

  3. Healthy Buildings and Green Building Rating Systems; Gezond bouwen en duurzaamheidslabels

    Energy Technology Data Exchange (ETDEWEB)

    Bergs, J.; Renes, S. [BenR Adviseurs voor duurzaamheid, Amersfoort (Netherlands)

    2010-11-15

    The awareness of health issues related to buildings has heightened past decades. Indoor Environmental Quality (IEQ) has been addressed in most Green Building Rating Systems nowadays. This article analyses the scope of IEQ (Indoor Environmental Quality) within Rating Systems GPR Gebouw, BREEAM-NL (Dutch version of Building Research Establishment's Environmental Assessment Method) and LEED (Leadership in Energy and Environmental Design). Each Rating System allocates health aspects. However, none of these Rating Systems addresses a complete set of relevant aspects. High ratings do not guarantee healthy buildings. It is concluded that, in general, credits for energy efficiency do not interfere with credits for enhanced indoor environmental quality. [Dutch] Gezondheidsaspecten van gebouwen hebben afgelopen decennia steeds meer en integraler aandacht gekregen. In de instrumenten GPR Gebouw, BREEAM-NL (Nederlandse versien van 'Building Research Establishment's Environmental Assessment Method') en LEED (Leadership in Energy and Environmental Design) is gezondheid 1 van de duurzaamheidsthema's, in dit artikel wordt geconcludeerd dat deze instrumenten veel gezondheidsaspecten dekken maar dat geen enkel instrument echt volledig is. De 1 legt meer accent op gezondheid, de ander meer op comfort. Een hoog label biedt geen garantie voor een gezond gebouw. De instrumenten bevatten weinig potentieel strijdige aspecten. Gezond en energiezuinig bouwen gaan volgens deze instrumenten goed samen.

  4. Residents’ Support in Major Local Events: Leeds Pride.

    OpenAIRE

    Pappas, Nikolaos

    2016-01-01

    This article examines the extent to which community participation and perceived impacts have an influence on residents' support of major events, more specifically, the Leeds Pride celebration. The research examines the perspectives of 400 Leeds permanent residents. The study tests a structural equation model, which has its theoretical basis in social exchange theory. It examines the constructs of community participation, perceived positive and negative impacts, and community support, includin...

  5. Cost analysis of LEED certified United States navy buildings

    OpenAIRE

    Kirar, Carl V.

    2011-01-01

    CIVINS (Civilian Institutions) Thesis document A study was completed at UW-Madison in 2010 that reviewed the energy consumption of US Navy buildings which earned Leadership in Energy and Environmental Design (LEED) certification by the United States Green Building Council (USGBC). The research compared LEED certified buildings to a commercial counterpart within the US Navy inventory against Executive Order (EO) 13423. The EO mandated that all federal agencies meet a 30 percent reduction of...

  6. LEED crystallography studies of the structure of clean and adsorbate-covered Ir, Pt and Rh crystal surfaces

    International Nuclear Information System (INIS)

    Koestner, R.J.

    1982-08-01

    There have only been a few Low Energy Electron Diffraction (LEED) intensity analyses carried out to determine the structure of molecules adsorbed on metal surfaces; most surface crystallography studies concentrated on the structure of clean unreconstructed or atomic adsorbate-covered transition metal faces. The few molecular adsorption systems already investigated by dynamical LEED are CO on Ni(100), Cu(100) and Pd(100) as well as C 2 H 2 and C 2 H 4 adsorbed on Pt(111). The emphasis of this thesis research has been to extend the applicability of LEED crystallography to the more complicated unit cells found in molecular overlayers on transition metals or in there constructed surfaces of clean transition metals

  7. LEED crystallography studies of the structure of clean and adsorbate-covered Ir, Pt and Rh crystal surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Koestner, R.J.

    1982-08-01

    There have only been a few Low Energy Electron Diffraction (LEED) intensity analyses carried out to determine the structure of molecules adsorbed on metal surfaces; most surface crystallography studies concentrated on the structure of clean unreconstructed or atomic adsorbate-covered transition metal faces. The few molecular adsorption systems already investigated by dynamical LEED are CO on Ni(100), Cu(100) and Pd(100) as well as C/sub 2/H/sub 2/ and C/sub 2/H/sub 4/ adsorbed on Pt(111). The emphasis of this thesis research has been to extend the applicability of LEED crystallography to the more complicated unit cells found in molecular overlayers on transition metals or in there constructed surfaces of clean transition metals.

  8. Assessment of Energy Credits in LEED-Certified Buildings Based on Certification Levels and Project Ownership

    Directory of Open Access Journals (Sweden)

    Asli Pelin Gurgun

    2018-02-01

    Full Text Available Compared to other categories, the Energy and Atmosphere category contributes the most to the maximum obtainable points in the Leadership in Energy and Environmental Design (LEED certification system. The objective of the study was to identify the extent to which project teams take advantage of the credits in the Energy and Atmosphere category of LEED. This study analyzes the performance of practitioners in achieving points in the Energy and Atmosphere credits of LEED-New Construction (NC 2009 for 1500 buildings that received LEED certification in the US. For a better understanding of the credit patterns, the differences in the performance of practitioners are investigated relative to certification levels and project ownership. Achievement in credits is calculated in terms of percent of maximum points (PMP, since the maximum achievable points differ for each credit. Practitioners’ achievements in the credits were ranked as follows: (1 enhanced commissioning, (2 optimized energy performance, (3 enhanced refrigerant management, (4 green power, (5 measurement and verification, and (6 on-site renewable energy. The largest achievement differences were observed in the on-site renewable energy credit. Concerning building ownership, investors were found to optimize mostly energy efficiency and on-site renewable energy, but to mostly skip enhanced refrigerant management. Performance in the measurement and verification credit was similar for all owner types, whereas investors performed differently from corporations, and government agencies in the enhanced commissioning credit. Practitioners who recognize these priorities and differences are expected to be better positioned to make sustainability-related decisions in building design and construction.

  9. LEED conformity inside and outside. Headquarters of the Deutsche Boerse in LEED {sup registered} Platin; Aussen und innen LEED-konform. Zentrale der Deutschen Boerse in LEED {sup registered} Platin

    Energy Technology Data Exchange (ETDEWEB)

    Bloedorn, Heike

    2011-07-01

    Due to the sustainable design of building, the new corporate headquarters of the group German Stock Exchange in Frankfurt (Federal Republic of Germany) with an investment of nearly 230 million Euro has been distinguished as the first skyscraper in Germany with the LEED platinum certification (as the highest category of the U.S. Green Building Council). The design of the 21-story building was by the architects KSP Engel Juergen Architekten GmbH (Frankfurt, Federal Republic of Germany). The project was developed by Gross Partner and Grundstuecksentwicklungsgesellschaft mbH (Frankfurt, Federal Republic of Germany) and Lang and Cie. Real Estate (Frankfurt, Federal Republic of Germany). The innovative energy concept was realized by Lenz Weber Ingenieure (Frankfurt, Federal Republic of Germany) in cooperation with EB-Partner GmbH and Co. KG (Frankfurt/Nuernberg, Federal Republic) and TP Electrical Plan (Gaggenau, Federal Republic of Germany). The stringent sustainability criteria in the interior construction were accomplished by feco wood materials in the form of displaceable system partition walls and sound absorbing doors.

  10. Performance or marketing benefits? The case of LEED certification.

    Science.gov (United States)

    Matisoff, Daniel C; Noonan, Douglas S; Mazzolini, Anna M

    2014-01-01

    Green building adoption is driven by both performance-based benefits and marketing based benefits. Performance based benefits are those that improve performance or lower operating costs of the building or of building users. Marketing benefits stem from the consumer response to green certification. This study illustrates the relative importance of the marketing based benefits that accrue to Leadership in Energy and Environmental Design (LEED) buildings due to green signaling mechanisms, specifically related to the certification itself are identified. Of course, all participants in the LEED certification scheme seek marketing benefits. But even among LEED participants, the interest in green signaling is pronounced. The green signaling mechanism that occurs at the certification thresholds shifts building patterns from just below to just above the threshold level, and motivates builders to cluster buildings just above each threshold. Results are consistent across subsamples, though nonprofit organizations appear to build greener buildings and engage in more green signaling than for-profit entities. Using nonparametric regression discontinuity, signaling across different building types is observed. Marketing benefits due to LEED certification drives organizations to build "greener" buildings by upgrading buildings at the thresholds to reach certification levels.

  11. Extending the range of low energy electron diffraction (LEED) surface structure determination: Co-adsorbed molecules, incommensurate overlayers and alloy surface order studied by new video and electron counting LEED techniques

    International Nuclear Information System (INIS)

    Ogletree, D.F.

    1986-11-01

    LEED multiple scattering theory is briefly summarized, and aspects of electron scattering with particular significance to experimental measurements such as electron beam coherence, instrument response and phonon scattering are analyzed. Diffuse LEED experiments are discussed. New techniques that enhance the power of LEED are described, including a real-time video image digitizer applied to LEED intensity measurements, along with computer programs to generate I-V curves. The first electron counting LEED detector using a ''wedge and strip'' position sensitive anode and digital electronics is described. This instrument uses picoampere incident beam currents, and its sensitivity is limited only by statistics and counting times. Structural results on new classes of surface systems are presented. The structure of the c(4 x 2) phase of carbon monoxide adsorbed on Pt(111) has been determined, showing that carbon monoxide molecules adsorb in both top and bridge sites, 1.85 +- 0.10 A and 1.55 +- 0.10 A above the metal surface, respectively. The structure of an incommensurate graphite overlayer on Pt(111) is analyzed. The graphite layer is 3.70 +- 0.05 A above the metal surface, with intercalated carbon atoms located 1.25 +- 0.10 A above hollow sites supporting it. The (2√3 x 4)-rectangular phase of benzene and carbon monoxide coadsorbed on Pt(111) is analyzed. Benzene molecules adsorb in bridge sites parallel to and 2.10 +- 0.10 A above the surface. The carbon ring is expanded, with an average C-C bond length of 1.72 +- 0.15 A. The carbon monoxide molecules also adsorb in bridge sites. The structure of the (√3 x √3) reconstruction on the (111) face of the α-CuAl alloy has been determined

  12. Extending the range of low energy electron diffraction (LEED) surface structure determination: Co-adsorbed molecules, incommensurate overlayers and alloy surface order studied by new video and electron counting LEED techniques

    Energy Technology Data Exchange (ETDEWEB)

    Ogletree, D.F.

    1986-11-01

    LEED multiple scattering theory is briefly summarized, and aspects of electron scattering with particular significance to experimental measurements such as electron beam coherence, instrument response and phonon scattering are analyzed. Diffuse LEED experiments are discussed. New techniques that enhance the power of LEED are described, including a real-time video image digitizer applied to LEED intensity measurements, along with computer programs to generate I-V curves. The first electron counting LEED detector using a ''wedge and strip'' position sensitive anode and digital electronics is described. This instrument uses picoampere incident beam currents, and its sensitivity is limited only by statistics and counting times. Structural results on new classes of surface systems are presented. The structure of the c(4 x 2) phase of carbon monoxide adsorbed on Pt(111) has been determined, showing that carbon monoxide molecules adsorb in both top and bridge sites, 1.85 +- 0.10 A and 1.55 +- 0.10 A above the metal surface, respectively. The structure of an incommensurate graphite overlayer on Pt(111) is analyzed. The graphite layer is 3.70 +- 0.05 A above the metal surface, with intercalated carbon atoms located 1.25 +- 0.10 A above hollow sites supporting it. The (2..sqrt..3 x 4)-rectangular phase of benzene and carbon monoxide coadsorbed on Pt(111) is analyzed. Benzene molecules adsorb in bridge sites parallel to and 2.10 +- 0.10 A above the surface. The carbon ring is expanded, with an average C-C bond length of 1.72 +- 0.15 A. The carbon monoxide molecules also adsorb in bridge sites. The structure of the (..sqrt..3 x ..sqrt..3) reconstruction on the (111) face of the ..cap alpha..-CuAl alloy has been determined.

  13. ENERGY STAR and Green Buildings--Using ENERGY STAR Resources for Green Building Rating Systems: LEED[R], Green Globes[R] and CHPS

    Science.gov (United States)

    Utebay, Kudret

    2011-01-01

    Every building, from the smallest school to the tallest skyscraper, uses energy. This energy is most often generated by burning fossil fuels, which releases greenhouse gases into the atmosphere and contributes to climate change. Existing commercial buildings offer a significant opportunity for low-cost, immediate emissions and energy cost…

  14. Assessment of energy credits for the enhancement of the Egyptian Green Pyramid Rating System

    International Nuclear Information System (INIS)

    Abdel Aleem, Shady H.E.; Zobaa, Ahmed F.; Abdel Mageed, Hala M.

    2015-01-01

    Energy is one of the most important categories in the Green Building Rating Systems all over the world. Green Building is a building that meets the energy requirements of the present with low energy consumption and investment costs without infringing on the rights of forthcoming generations to find their own needs. Despite having more than a qualified rating system, it is clear that each system has different priorities and needs on the other. Accordingly, this paper proposes a methodology using the Analytic Hierarchy Process (AHP) for assessment of the energy credits through studying and comparing four of the common global rating systems, the British Building Research Establishment Environmental Assessment Method (BREEAM), the American Leadership in Energy and Environmental Design (LEED), the Australian Green Stars (GS), and the PEARL assessment system of the United Arab Emirates, in order to contribute to the enhancement of the Egyptian Green Pyramid Rating System (GPRS). The results show the mandatory and optional energy credits that should be considered with their proposed weights according to the present and future needs of green Egypt. The results are compared to data gathered through desk studies and results extracted from recent questionnaires. - Highlights: • The Egyptian rating system is underway but not on track. • The main objective is the enhancement of the Egyptian rating system. • We propose a methodology for assessment of the energy credits. • The results show the optional energy credits with their optimal weights. • The results show the mandatory energy credits that should be considered.

  15. Achieving LEED credit for ergonomics: Laying the foundation.

    Science.gov (United States)

    Lynch, Mallory

    2014-01-01

    Despite guidance from the United States Green Building Council (USGBC) on the requirements for earning a Leadership in Energy and Environmental Design (LEED) ergonomics credit in the Innovation in Design and Innovation in Operations category, few projects have received the credit. The University of California, Berkeley ergonomics program, Ergonomics@Work, has aligned the ergonomics strategy to those of the USGBC and LEED to achieve the ergonomics credit in several new buildings. This article describes the steps needed to obtain the credit and highlights the opportunities it creates to partner with the project team to promote ergonomics. As a profession it is up to ergonomists to create the road map that incorporates ergonomics into the green building design.

  16. Sustainability assessment, rating systems and historical buildings Case study: Rehabilitated construction in a university site

    Directory of Open Access Journals (Sweden)

    Sadrykia Somayeh

    2016-01-01

    Full Text Available This paper explores the relationship between the indicators and different factors that “rating systems for green projects” concentrates on, and principles and factors considered in the rehabilitation of historical buildings. In recent years, different methods and systems concerned and improved for assessing environmental sustainability. LEED (Leadership in Energy and Environmental Design and BREEAM (Building Research Establishment (BRE Environmental Assessment Method are two most commonly used rating systems, established in U.S and UK. These systems comprise some categories and different factors to achieve environmentally responsible design. Firstly, this study focuses on the list of rating systems indicators and criteria. Secondly this paper investigates a historical rehabilitated building in the site of Tabriz Art University, as a case study and has tried to compile its green design elements. Finally, this work intends to compare mentioned elements with indicators and factors of building rating systems. Findings of the study revealed that “Materials and Resources”, “indoor environmental quality” and also “Sustainable Sites” ,the most significant indicator of rating systems, had major and important role in the rehabilitation of the building. Beyond this materials’ life cycle was considerable in construction.

  17. An Analysis of the Most Adopted Rating Systems for Assessing the Environmental Impact of Buildings

    Directory of Open Access Journals (Sweden)

    Elena Bernardi

    2017-07-01

    Full Text Available Rating systems for assessing the environmental impact of buildings are technical instruments that aim to evaluate the environmental impact of buildings and construction projects. In some cases, these rating systems can also cover urban-scale projects, community projects, and infrastructures. These schemes are designed to assist project management in making the projects more sustainable by providing frameworks with precise criteria for assessing the various aspects of a building’s environmental impact. Given the growing interest in sustainable development worldwide, many rating systems for assessing the environmental impact of buildings have been established in recent years, each one with its peculiarities and fields of applicability. The present work is motivated by an interest in emphasizing such differences to better understand these rating systems and extract the main implications to building design. It also attempts to summarize in a user-friendly form the vast and fragmented assortment of information that is available today. The analysis focuses on the six main rating systems: the Building Research Establishment Environmental Assessment Methodology (BREEAM, the Comprehensive Assessment System for Built Environment Efficiency (CASBEE, the Deutsche Gesellschaft für Nachhaltiges Bauen (DGNB, the Haute Qualité Environnementale (HQETM, the Leadership in Energy and Environmental Design (LEED, and the Sustainable Building Tool (SBTool.

  18. Rate Adaptive OFDMA Communication Systems

    International Nuclear Information System (INIS)

    Abdelhakim, M.M.M.

    2009-01-01

    Due to the varying nature of the wireless channels, adapting the transmission parameters, such as code rate, modulation order and power, in response to the channel variations provides a significant improvement in the system performance. In the OFDM systems, Per-Frame adaptation (PFA) can be employed where the transmission variables are fixed over a given frame and may change from one frame to the other. Subband (tile) loading offers more degrees of adaptation such that each group of carriers (subband) uses the same transmission parameters and different subbands may use different parameters. Changing the code rate for each tile in the same frame, results in transmitting multiple codewords (MCWs) for a single frame. In this thesis a scheme is proposed for adaptively changing the code rate of coded OFDMA systems via changing the puncturing rate within a single codeword (SCW). In the proposed structure, the data is encoded with the lowest available code rate then it is divided among the different tiles where it is punctured adaptively based on some measure of the channel quality for each tile. The proposed scheme is compared against using multiple codewords (MCWs) where the different code rates for the tiles are obtained using separate encoding processes. For bit interleaved coded modulation architecture two novel interleaving methods are proposed, namely the puncturing dependant interleaver (PDI) and interleaved puncturing (IntP), which provide larger interleaving depth. In the PDI method the coded bits with the same rate over different tiles are grouped for interleaving. In IntP structure the interleaving is performed prior to puncturing. The performance of the adaptive puncturing technique is investigated under constant bit rate constraint and variable bit rate. Two different adaptive modulation and coding (AMC) selection methods are examined for variable bit rate adaptive system. The first is a recursive scheme that operates directly on the SNR whereas the second

  19. True mean rate measuring system

    International Nuclear Information System (INIS)

    Eichenlaub, D.P.

    1980-01-01

    A digital radiation-monitoring system for nuclear power plants uses digital and microprocessor circuitry to enable rapid processing of pulse information from remote radiation monitors. The pulse rates are analyzed to determine whether new pulse-rate information is statisticaly the same as that previously received and to determine the best possible averaging time, which can be changed so that the statistical error remains below a specified level while the system response time remains short. Several data modules each process the pulse-rate information from several remote radiation monitors. Each data module accepts pulse data from each radiation monitor and measures the true average or mean pulse rate of events occurring with a Poisson distribution to determine the radiation level. They then develop digital output signals which indciate the respective radiation levels and which can be transmitted via multiplexer circuits for additional processing and display. The data modules can accept signals from remote control stations or computer stations via the multiplexer circuit to change operating thresholds and alarm levels in their memories. A check module scans the various data modules to determine whether the output signals are valid. It also acts as a redundant data module and will automatically replace an inoperative unit. (DN)

  20. Uno strumento per la creazione di valore nella realizzazione di edifici sostenibili: la certificazione LEED

    Directory of Open Access Journals (Sweden)

    S. Rick Fedrizzi

    2014-06-01

    Full Text Available Il presente lavoro ha l’obiettivo di delineare gli aspetti chiave della sostenibilità in ambito edilizio focalizzando l’attenzione sul sistema di certificazione LEED® quale strumento “universale” di supporto per la realizzazione, gestione e valutazione di edifici sostenibili. Nella prima parte del lavoro si descrive la rapida diffusione della certificazione LEED nel recente passato quale diretta conseguenza della capacità di questo strumento di rating di adattarsi sia alle specifiche tipologie di edifici, sia alle diversità climatiche e morfologiche dei siti. Nella seconda parte si procede invece a presentare ed analizzare gli aspetti economico-finanziari degli edifici sostenibili con riferimento sia alle metodologie valutative applicabili, sia ai dati della letteratura. Partendo dalle esperienze internazionali in tema di sostenibilità, si procede successivamente a descrivere la situazione italiana, evidenziando la percezione del mercato e le opportunità di sviluppo future.

  1. Radiofrequency electromagnetic fields in the Cookridge area of Leeds

    CERN Document Server

    Fuller, K; Judd, P M; Lowe, A J; Shaw, J

    2002-01-01

    On the 8 and 9 May 2002 representatives of the National Radiological Protection Board (NRPB) performed a radiofrequency electromagnetic field survey in the Cookridge area of Leeds in order to assess exposure to radio signals from transmitters mounted on a water tower/a lattice tower and a radio station tower. Guidelines on limiting exposure to radio signals have been published by NRPB and the International Commission on Non-Ionizing Radiation Protection (ICNIRP). These guidelines are designed to prevent established adverse effects on human health. During this survey, the total exposures due to all radio signals from 30 MHz to 18000 MHz (18 GHz) were measured. This frequency range was chosen as it includes mobile phone base station transmissions, which are at around 900 and 1800 MHz and super high frequency (SHF) transmissions from most of the large microwave dish antennas mounted on the towers. In addition, other major sources of radiofrequency electromagnetic fields in the environment such as broadcast radio...

  2. Sokol Blosser Barrel Aging Cellar : green roofs and LEED{sup TM} buildings in the rural context

    Energy Technology Data Exchange (ETDEWEB)

    Cravens, L.L. [Sera Architects Inc., Portland, OR (United States)

    2004-07-01

    An earth covered structure that stores 900 barrels of wine at the Sokol Blosser Winery located in Yamhill Valley, southeast of Portland, Oregon was presented. The owner's decision to build as sustainably as possible when constructing the barrel aging cellar was reinforced by their involvement in the Oregon Natural Step Network, a non-profit organization that promotes sustainability principles in any endeavor. The sustainable project design solution led by SERA Architects met the winery's requirements for an underground structure capable of storing 900 barrels of wine in three chambers; natural daylight throughout; control over the temperature and humidity; natural ventilation; the use of sustainable materials, and minimal materials; use of local products; preserving the maximum existing open area; and, minimizing construction demolition and waste. The Leadership in Energy and Environmental Design (LEED) criteria for the green building rating system was used to measure the green construction practices. The many benefits of burying the building were identified, namely the cooling system was eliminated, which reduced the cost of the mechanical system, reduced the major draw for energy, and eliminated any use of ozone depleting refrigerants. The roof's waterproofing system was provided by Tremco. Combined with a non-engineered earth cover the manufacturer provided a warranty of 20 years but predicted a 60 year life for the roof. The Roof sandwich structure from top down was described in detail and illustrations were presented. The final calculations indicate a $750 annual energy savings above a traditional space. 6 figs.

  3. Universidad de Leeds - Gran Bretaña

    Directory of Open Access Journals (Sweden)

    Chamberlin, -

    1977-11-01

    Full Text Available Located 1,500 m from the center of the city, the Leeds University complex actively participates in city life. Designed in the 60's and built later on, this architectonic complex is outstanding because it offers an «ideal» city, perfectly integrated in the «real» city and conditioned to its own needs, to a great extent. In the beginning, this challenge of converting this university complex with a capacity for 10,000 students, in an architectonically attractive urban center met with difficulties referring to traffic and parking problems corresponding to a city as large as the one projected; this obstacle was overcome by adequate organization of underground and overhead traffic arteries which reserved large garden areas exclusively for pedestrians, freeing them from the traffic congestion and offering the pleasant and relaxed atmosphere required. The large «campus» ¡s sub-divided into different garden areas, connected one to the other and In the center of each one we have a varied and complementary architecture, which breaks with the conventional monolithic style.Situado a 1.500 m del centro de la ciudad, el conjunto universitario de Leeds participa activamente de la misma. Concebido en la década de los 60, y construido posteriormente, este complejo arquitectónico se destaca por encerrar una propuesta de ciudad «ideal», perfectamente integrada en la ciudad «real» y sujeta en buena medida a sus mismas necesidades. La alternativa de convertir a este conjunto universitario, con capacidad para 10.000 estudiantes, en un núcleo urbano arquitectónicamente atractivo, tropezó inicialmente con los condicionamientos surgidos del tráfico, circulación y estacionamiento de vehículos, correspondientes a la magnitud de la ciudad proyectada; impedimento que fue resuelto de forma adecuada mediante la organización de una red subterránea y superficial de circulación vehicular, que reserva grandes espacios verdes para la circulaci

  4. Situating CASBEE, a Japanese-made unique building rating and certification system, within a broader context

    Directory of Open Access Journals (Sweden)

    Raymond J. Cole

    2014-06-01

    Full Text Available An underlying premise of the voluntary assessments and certifications offered by existing major building performance assessment systems is that if the market is provided with improved information and mechanisms, a discerning client group can and will provide leadership in environmental responsibility, and that others will follow suit to remain competitive. Building environmental ratings have provided building owners with a credible and objective means to communicate to prospective tenants the environmental qualities of the building they are leasing and, by emphasizing more demanding performance goals and the benefits over typical practice, have begun to reframe expectations. Over the past twenty plus years, building environmental assessment has matured into a legitimate area of research and study. Assessment tools in use worldwide generally fall into two general categories: 1 Those developed by an organization within a country that maintains and manages it and provides the associated educational support and operational infrastructure. All the major recognized systems – BREEAM, LEED, CASBEE, Green Star in Australia, etc., – fall into this category. 2 Those developed by academics either for research purposes or in hopes that they could become a certification system but to date have yet to gain widespread adoption in their respective countries.

  5. Study of the local structure of binary surfaces by electron diffraction (XPS, LEED)

    OpenAIRE

    Gereová, Katarína

    2006-01-01

    Study of local structure of binary surface with usage of ultra-thin film of cerium deposited on a Pd (111) single-crystal surface is presented. X-ray photoelectron spectroscopy and diffraction (XPS, XPD), angle resolved UV photoemission spectroscopy (ARUPS) and low energy electron diffraction (LEED) was used for our investigations. LEED and X-ray excited photoemission intensities results represent a surface-geometrical structure. As well, mapping of ultra-violet photoelectron intensities as a...

  6. 76 FR 48159 - Integrated System Power Rates

    Science.gov (United States)

    2011-08-08

    ... DEPARTMENT OF ENERGY Southwestern Power Administration Integrated System Power Rates AGENCY... American Electric Reliability Corporation and to cover increased investments and replacements in..., prepared a Current Power Repayment Study using existing system rates. The Study indicates that Southwestern...

  7. Laser Pyro System Standardization and Man Rating

    Science.gov (United States)

    Brown, Christopher W.

    2004-01-01

    This viewgraph presentation reviews an X-38 laser pyro system standardization system designed for a new manned rated program. The plans to approve this laser initiation system and preliminary ideas for this system are also provided.

  8. Radiofrequency electromagnetic fields in the Cookridge area of Leeds

    International Nuclear Information System (INIS)

    Fuller, K.; Gulson, A.D.; Judd, P.M.; Lowe, A.J.; Shaw, J.

    2002-01-01

    On the 8 and 9 May 2002 representatives of the National Radiological Protection Board (NRPB) performed a radiofrequency electromagnetic field survey in the Cookridge area of Leeds in order to assess exposure to radio signals from transmitters mounted on a water tower/a lattice tower and a radio station tower. Guidelines on limiting exposure to radio signals have been published by NRPB and the International Commission on Non-Ionizing Radiation Protection (ICNIRP). These guidelines are designed to prevent established adverse effects on human health. During this survey, the total exposures due to all radio signals from 30 MHz to 18000 MHz (18 GHz) were measured. This frequency range was chosen as it includes mobile phone base station transmissions, which are at around 900 and 1800 MHz and super high frequency (SHF) transmissions from most of the large microwave dish antennas mounted on the towers. In addition, other major sources of radiofrequency electromagnetic fields in the environment such as broadcast radio and television transmissions are included in this range. Measurements of power density were made at eight locations in the vicinity of the transmitter sites. Comparison of the measurements with the guidelines showed that the total exposure from radio signals measured between 30 MHz and 18 GHz ranged from 0.26 millionths (0.000026%) to 190 millionths (0.019%) of the NRPB investigation level and from 1.6 millionths (0.00016%) to 1400 millionths (0.14%) of the ICNIRP reference level for exposure of the general public. All the measured exposures are therefore many times below guideline levels and are not considered hazardous. (author)

  9. 77 FR 36536 - Examination Rating System

    Science.gov (United States)

    2012-06-19

    ... operations of the Bank System's Office of Finance, ratings were assigned only to the areas of Corporate... FEDERAL HOUSING FINANCE AGENCY [No. 2012-N-06] Examination Rating System AGENCY: Federal Housing Finance Agency. ACTION: Notice with request for comments. SUMMARY: The Federal Housing Finance Agency...

  10. The Optimal Interest Rates and the Current Interest Rate System

    Directory of Open Access Journals (Sweden)

    Ioannis N. Kallianiotis

    2014-12-01

    Full Text Available The paper discusses the current target interest rate, which is closed to zero with the new experiment of quantitative easing since 2009 and has reduced the rate of return and the income and has made the real savings rate negative. This target rate has not reduced unemployment and has not improved growth (it is not optimal, but has increased the debt of individuals and the low taxes on businesses have magnified the budget deficits and the national debt. People were borrowing the present value of their uncertain future wealth and their high debt and low income raise the risk and this high risk premium heighten the interest rate on loans, especially on credit cards. The current monetary system needs to be changed and an interest rate floor on deposits (savings and an interest rate ceiling on individuals‟ loans (borrowings is necessary to improve social welfare, fairness, and justice in our society and not to support only disintermediation (financial markets. The middle class cannot work only to pay taxes and interest on its debt (redistribution of their wealth to government and banks or worse to be in chronic unemployment. Many home owners defaulted on their loans payments and their homes are foreclosed. They will end up without property (real assets. The unconcern towards the middle class will affect negatively the entire socio-economic structure of the nation and after losing its productive power, it will start declining, as history has shown to us with so many empires that do not exist anymore. We hope the leaders (the democratic governments to improve public policies, to regulate the financial market and institutions, and to satisfy their policy ultimate objective, which is citizens‟ perfection and the nation‟s highest point of prosperity.

  11. Five-Star Quality Rating System

    Data.gov (United States)

    U.S. Department of Health & Human Services — CMS created the Five-Star Quality Rating System to help consumers, their families, and caregivers compare nursing homes more easily and to help identify areas about...

  12. Integrating Building Information Modeling and Green Building Certification: The BIM-LEED Application Model Development

    Science.gov (United States)

    Wu, Wei

    2010-01-01

    Building information modeling (BIM) and green building are currently two major trends in the architecture, engineering and construction (AEC) industry. This research recognizes the market demand for better solutions to achieve green building certification such as LEED in the United States. It proposes a new strategy based on the integration of BIM…

  13. Evaluation of the Work-Place Cooperative Project in Geography Degrees at the University of Leeds.

    Science.gov (United States)

    Hogg, James

    1998-01-01

    Describes the context and objective of a Work-Place Cooperative Project (WPCP) established in the School of Geography at the University of Leeds in 1995. The project presents students with business, commerce, industry, and environmental research issues that have geographical dimensions. Includes a number of examples from the WPCP. (MJP)

  14. System for increasing laser pulse rate

    International Nuclear Information System (INIS)

    1980-01-01

    A technique of static elements is disclosed for combining a plurality of laser beams having time sequenced, pulsed radiation to achieve an augmented pulse rate. The technique may also be applied in a system for combining both time sequenced pulses and frequency distinct pulses for use in a system for isotope enrichment. (author)

  15. Allbutt of Leeds and Duchenne de Boulogne: Newly discovered insights on Duchenne by a British neuropsychiatrist.

    Science.gov (United States)

    Reynolds, E H; Broussolle, E

    2018-02-01

    It is well-established that Guillaume-Benjamin-Amand Duchenne de Boulogne (1806-1875), and Jean-Martin Charcot (1825-1893) were the founding fathers of Parisian and French neurology during the second half of the 19th century, although much more is known about Charcot than about his "master" Duchenne. In Britain, Thomas Clifford Allbutt (1836-1925) was Leeds' most distinguished physician of the 19th century, eventually becoming Regius Professor of Physic at Cambridge. Allbutt's 1860-1861 year of postgraduate study in Paris and his friendship with Duchenne profoundly influenced his own contributions to nervous system and mental diseases, partly in collaboration with his colleague James Crichton-Browne (1840-1938) at the nearby West Riding Lunatic Asylum in Wakefield, Yorkshire. The present report briefly recalls the careers of Duchenne and Allbutt, and also presents a unique account by Allbutt of Duchenne in action at the height of his powers, investigating and defining the previously uncharted field of neuromuscular diseases with the aid of his localized electrization techniques. This account is discussed in relation to: Duchenne's personality and pioneering neurological achievements; the origins of French neurology; and the development of Anglo-French neurological relationships during the 19th century. Interestingly, both Duchenne and Crichton-Browne separately made important and much-appreciated contributions to the third major book by Charles Darwin (1809-1882), The Expression of the Emotions in Man and Animals, published in 1872. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  16. Delta count-rate monitoring system

    International Nuclear Information System (INIS)

    Van Etten, D.; Olsen, W.A.

    1985-01-01

    A need for a more effective way to rapidly search for gamma-ray contamination over large areas led to the design and construction of a very sensitive gamma detection system. The delta count-rate monitoring system was installed in a four-wheel-drive van instrumented for environmental surveillance and accident response. The system consists of four main sections: (1) two scintillation detectors, (2) high-voltage power supply amplifier and single-channel analyzer, (3) delta count-rate monitor, and (4) count-rate meter and recorder. The van's 6.5-kW generator powers the standard nuclear instrument modular design system. The two detectors are mounted in the rear corners of the van and can be run singly or jointly. A solid-state bar-graph count-rate meter mounted on the dashboard can be read easily by both the driver and passenger. A solid-state strip chart recorder shows trends and provides a permanent record of the data. An audible alarm is sounded at the delta monitor and at the dashboard count-rate meter if a detected radiation level exceeds the set background level by a predetermined amount

  17. FPGA Implementation of Heart Rate Monitoring System.

    Science.gov (United States)

    Panigrahy, D; Rakshit, M; Sahu, P K

    2016-03-01

    This paper describes a field programmable gate array (FPGA) implementation of a system that calculates the heart rate from Electrocardiogram (ECG) signal. After heart rate calculation, tachycardia, bradycardia or normal heart rate can easily be detected. ECG is a diagnosis tool routinely used to access the electrical activities and muscular function of the heart. Heart rate is calculated by detecting the R peaks from the ECG signal. To provide a portable and the continuous heart rate monitoring system for patients using ECG, needs a dedicated hardware. FPGA provides easy testability, allows faster implementation and verification option for implementing a new design. We have proposed a five-stage based methodology by using basic VHDL blocks like addition, multiplication and data conversion (real to the fixed point and vice-versa). Our proposed heart rate calculation (R-peak detection) method has been validated, using 48 first channel ECG records of the MIT-BIH arrhythmia database. It shows an accuracy of 99.84%, the sensitivity of 99.94% and the positive predictive value of 99.89%. Our proposed method outperforms other well-known methods in case of pathological ECG signals and successfully implemented in FPGA.

  18. 77 FR 67644 - Examination Rating System

    Science.gov (United States)

    2012-11-13

    ... condition, performance, and risk management. Under the new rating system, each Bank and Enterprise, as well... Home Loan Bank's or Enterprise's capital, asset quality, management, earnings, liquidity, sensitivity... performance from business fluctuations and adverse changes in the economic environment. Risk management...

  19. Apparent exchange rate imaging in anisotropic systems

    DEFF Research Database (Denmark)

    Sønderby, Casper Kaae; Lundell, Henrik M; Søgaard, Lise V

    2014-01-01

    Double-wave diffusion experiments offer the possibility of probing correlation between molecular diffusion at multiple time points. It has recently been shown that this technique is capable of measuring the exchange of water across cellular membranes. The aim of this study was to investigate...... the effect of macroscopic tissue anisotropy on the measurement of the apparent exchange rate (AXR) in multicompartment systems....

  20. Corrosion Rate Monitoring in District Heating Systems

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel; Nielsen, Lars Vendelbo; Andersen, A.

    2005-01-01

    be applicable, and if on-line monitoring could improve the quality control. Water quality monitoring was applied as well as corrosion rate monitoring with linear polarization resistance (LPR), electrochemical impedance spectroscopy (EIS), electrical resistance (ER) technique, mass loss and a crevice corrosion......Quality control in district heating systems to keep uniform corrosion rates low and localized corrosion minimal is based on water quality control. Side-stream units equipped with carbon steel probes for online monitoring were mounted in district heating plants to investigate which techniques would...... cell for localized corrosion risk estimation. Important variations in corrosion rate due to changes in make-up water quality were detected with the continuous monitoring provided by ER and crevice cell, while LPR gave unreliable corrosion rates. The acquisition time of two-three days for EIS...

  1. The power of joint application of LEED and DFT in quantitative surface structure determination

    International Nuclear Information System (INIS)

    Heinz, K; Hammer, L; Mueller, S

    2008-01-01

    It is demonstrated for several cases that the joint application of low-energy electron diffraction (LEED) and structural calculations using density functional theory (DFT) can retrieve the correct surface structure even though single application of both methods fails. On the experimental side (LEED) the failure can be due to the simultaneous presence of weak and very strong scatterers or to an insufficient data base leaving different structures with the same quality of fit between experimental data and calculated model intensities. On the theory side (DFT) it can be difficult to predict the coverage of an adsorbate or two different structures may own almost the same total energy, but only one of the structures is assumed in experiment due to formation kinetics. It is demonstrated how in the different cases the joint application of both methods-which yield about the same structural precision-offers a way out of the dilemma

  2. Indoor environmental quality differences between office types in LEED-certified buildings in the US

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young S. [School of Planning, Design, and Construction, Michigan State University, East Lansing, MI 48823 (United States); Guerin, Denise A. [College of Design, University of Minnesota, Twin Cities, MN 55108 (United States)

    2010-05-15

    The study compared IAQ, thermal quality, and lighting quality between 5 different office types in LEED-certified buildings in relation to employees' environmental satisfaction and their job performance. This was to provide workplaces where workers in each specific office environment could be provided with appropriate office settings regarding these IEQ criteria when organizations comply with LEED standards. The five types of office included private enclosed, private shared, open-plan with high cubicle over 5', open-plan with low cubicle lower than 5', and open-plan with no partitions (bullpen) offices. The study found IAQ enhanced workers' job performance in enclosed private offices more than both high cubicles and low cubicles. All four office types had higher satisfaction with the amount of light and visual comfort of light as well as more enhancement with job performance due to lighting quality than high cubicles. There was no difference in thermal quality between the five office types. IAQ and lighting quality were not different between enclosed private, enclosed shared, and bullpen office types, either. The study findings suggest a careful workplace design considering the height of partitions in LEED-certified buildings to improve employee's environmental satisfaction and job performance. (author)

  3. Investigation of reordered (001) Au surfaces by positive ion channeling spectroscopy, LEED and AES

    International Nuclear Information System (INIS)

    Appleton, B.R.; Noggle, T.S.; Miller, J.W.; Schow, O.E. III; Zehner, D.M.; Jenkins, L.H.; Barrett, J.H.

    1974-01-01

    As a consequence of the channeling phenomenon of positive ions in single crystals, the yield of ions Rutherford scattered from an oriented single crystal surface is dependent on the density of surface atoms exposed to the incident ion beam. Thus, the positive ion channeling spectroscopy (PICS) technique should provide a useful tool for studying reordered surfaces. This possibility was explored by examining the surfaces of epitaxially grown thin Au single crystals with the combined techniques of LEED-AES and PICS. The LEED and AES investigations showed that when the (001) surface was sputter cleaned in ultra-high vacuum, the normal (1 x 1) symmetry of the (001) surfaces reordered into a structure which gave a complex (5 x 20) LEED pattern. The yield and energy distributions of 1 MeV He ions scattered from the Au surfaces were used to determine the number of effective monolayers contributing to the normal and reordered surfaces. These combined measurements were used to characterize the nature of the reordered surface. The general applicability of the PICS technique for investigations of surface and near surface regions is discussed

  4. Reactor core flow rate control system

    International Nuclear Information System (INIS)

    Sakuma, Hitoshi; Tanikawa, Naoshi; Takahashi, Toshiyuki; Miyakawa, Tetsuya.

    1996-01-01

    When an internal pump is started by a variable frequency power source device, if magnetic fields of an AC generator are introduced after the rated speed is reached, neutron flux high scram occurs by abrupt increase of a reactor core flow rate. Then, in the present invention, magnetic fields for the AC generator are introduced at a speed previously set at which the fluctuation range of the reactor core flow rate (neutron flux) by the start up of the internal pump is within an allowable value. Since increase of the speed of the internal pump upon its start up is suppressed to determine the change of the reactor core flow rate within an allowable range, increase of neutron fluxes is suppressed to enable stable start up. Then, since transition boiling of fuels caused by abrupt decrease of the reactor core flow rate upon occurrence of abnormality in an external electric power system is prevented, and the magnetic fields for the AC generator are introduced in such a manner to put the speed increase fluctuation range of the internal pump upon start up within an allowable value, neutron flux high scram is not caused to enable stable start-up. (N.H.)

  5. FFTF integrated leak rate computer system

    International Nuclear Information System (INIS)

    Hubbard, J.A.

    1987-01-01

    The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled test reactor located on the Hanford site. The FFTF is the only reactor of this type designed and operated to meet the licensing requirements of the Nuclear Regulatory Commission. Unique characteristics of the FFTF that present special challenges related to leak rate testing include thin wall containment vessel construction, cover gas systems that penetrate containment, and a low-pressure design basis accident. The successful completion of the third FFTF integrated leak rate test 5 days ahead of schedule and 10% under budget was a major achievement for the Westinghouse Hanford Company. The success of this operational safety test was due in large part to a special network (LAN) of three IBM PC/XT computers, which monitored the sensor data, calculated the containment vessel leak rate, and displayed test results. The equipment configuration allowed continuous monitoring of the progress of the test independent of the data acquisition and analysis functions, and it also provided overall improved system reliability by permitting immediate switching to backup computers in the event of equipment failure

  6. Walkable new urban LEED_Neighborhood-Development (LEED-ND community design and children's physical activity: selection, environmental, or catalyst effects?

    Directory of Open Access Journals (Sweden)

    Stevens, Robert B

    2011-12-01

    Full Text Available Abstract Background Interest is growing in physical activity-friendly community designs, but few tests exist of communities explicitly designed to be walkable. We test whether students living in a new urbanist community that is also a pilot LEED_ND (Leadership in Energy and Environmental Design-Neighborhood Development community have greater accelerometer-measured moderate-to-vigorous physical activity (MVPA across particular time periods compared to students from other communities. We test various time/place periods to see if the data best conform to one of three explanations for MVPA. Environmental effects suggest that MVPA occurs when individuals are exposed to activity-friendly settings; selection effects suggest that walkable community residents prefer MVPA, which leads to both their choice of a walkable community and their high levels of MVPA; catalyst effects occur when walking to school creates more MVPA, beyond the school commute, on schooldays but not weekends. Methods Fifth graders (n = 187 were sampled from two schools representing three communities: (1 a walkable community, Daybreak, designed with new urbanist and LEED-ND pilot design standards; (2 a mixed community (where students lived in a less walkable community but attended the walkable school so that part of the route to school was walkable, and (3 a less walkable community. Selection threats were addressed through controlling for parental preferences for their child to walk to school as well as comparing in-school MVPA for the walkable and mixed groups. Results Minutes of MVPA were tested with 3 × 2 (Community by Gender analyses of covariance (ANCOVAs. Community walkability related to more MVPA during the half hour before and after school and, among boys only, more MVPA after school. Boys were more active than girls, except during the half hour after school. Students from the mixed and walkable communities--who attended the same school--had similar in-school MVPA levels, and

  7. Walkable new urban LEED_Neighborhood-Development (LEED-ND) community design and children's physical activity: selection, environmental, or catalyst effects?

    Science.gov (United States)

    2011-01-01

    Background Interest is growing in physical activity-friendly community designs, but few tests exist of communities explicitly designed to be walkable. We test whether students living in a new urbanist community that is also a pilot LEED_ND (Leadership in Energy and Environmental Design-Neighborhood Development) community have greater accelerometer-measured moderate-to-vigorous physical activity (MVPA) across particular time periods compared to students from other communities. We test various time/place periods to see if the data best conform to one of three explanations for MVPA. Environmental effects suggest that MVPA occurs when individuals are exposed to activity-friendly settings; selection effects suggest that walkable community residents prefer MVPA, which leads to both their choice of a walkable community and their high levels of MVPA; catalyst effects occur when walking to school creates more MVPA, beyond the school commute, on schooldays but not weekends. Methods Fifth graders (n = 187) were sampled from two schools representing three communities: (1) a walkable community, Daybreak, designed with new urbanist and LEED-ND pilot design standards; (2) a mixed community (where students lived in a less walkable community but attended the walkable school so that part of the route to school was walkable), and (3) a less walkable community. Selection threats were addressed through controlling for parental preferences for their child to walk to school as well as comparing in-school MVPA for the walkable and mixed groups. Results Minutes of MVPA were tested with 3 × 2 (Community by Gender) analyses of covariance (ANCOVAs). Community walkability related to more MVPA during the half hour before and after school and, among boys only, more MVPA after school. Boys were more active than girls, except during the half hour after school. Students from the mixed and walkable communities--who attended the same school--had similar in-school MVPA levels, and community groups

  8. Bretton Woods Fixed Exchange Rate System versus Floating Exchange Rate System

    OpenAIRE

    Geza, Paula; Giurca Vasilescu, Laura

    2011-01-01

    One of the most important issues of monetary policy is to find out whether the state should intervene among the exchange rates, taking into account the fact that changes in the exchange rates represent a significant transmission channel of the effects generated by the monetary policy. Taking into consideration the failure of fixed exchange rate regimes and the recent improvement of financial markets, the return in the near future to such a regime – as for example the Bretton Woods system –...

  9. Leak rate measurements and detection systems

    International Nuclear Information System (INIS)

    Kupperman, D.; Shack, W.J.; Claytor, T.

    1983-10-01

    A research program is under way to evaluate and develop improve leak detection systems. The primary focus of the work has been on acoustic emission detection of leaks. Leaks from artificial flaws, laboratory-generated IGSCCs and thermal fatigue cracks, and field-induced intergranular stress corrosion cracks (IGSCCs) from reactor piping have been examined. The effects of pressure, temperature, and leak rate and geometry on the acoustic signature are under study. The use of cross-correlation techniques for leak location and pattern recognition and autocorrelation for source discrimination is also being considered

  10. Exergy Rate Profile of Multicomponent Distillation System

    Directory of Open Access Journals (Sweden)

    Kehinde Adewale Adesina

    2016-07-01

    Full Text Available Exergy rate profiles, exergetic efficiency and irreversibility were used to examine the driving forces in multicomponent distillation system with the view to identifying feasible and efficient operating parameters. The mixture used comprised of 5% propane, 15% iso-butane, 25% nbutane, 20% iso-pentane and 35% n-pentane. Operating variables were feed temperature (-30 oC and -80 oC, pressure (800 kPa and 1200 kPa, and reflux-ratio (2 and 6. Stage-by-stage system exergy analysis was estimated. Column profiles of base case -30 oC, -80 oC, -30 oC-reflus ratio 6, -80 oC reflux ratio 6 and base case reflux ratio 6 did not crossed thus are thermodynamically feasible. Base case -30 oC-reflux ratio 2, -80 oC-reflux ratio 2, and base case-reflux ratio 2 were crossed and constricted and are infeasible. Base case results gave efficiency of 81.7% at depropanizer and 65.2% at debutanizer. Base cases sensitivity results with -30 oC, -80 oC and reflux ratio 6, efficiency range 57.40 – 70% and 65.20% - 54.90% for depropanizer and debutanizer respectively. Spitted cases gave 81.7% and 62.20% with more scatter profiles. Splitted feed base case -30 oC design gave the lowest overall system exergy loss rate of 1.12E+6 and efficiency of 95.70%. Design feasible parameters, system efficiency and irreversibility which form basis

  11. Cold Climate Structural Fire Danger Rating System?

    Directory of Open Access Journals (Sweden)

    Maria-Monika Metallinou

    2018-03-01

    Full Text Available Worldwide, fires kill 300,000 people every year. The fire season is usually recognized to be in the warmer periods of the year. Recent research has, however, demonstrated that the colder season also has major challenges regarding severe fires, especially in inhabited (heated wood-based structures in cold-climate areas. Knowledge about the effect of dry cellulose-based materials on fire development, indoor and outdoor, is a motivation for monitoring possible changes in potential fire behavior and associated fire risk. The effect of wind in spreading fires to neighboring structures points towards using weather forecasts as information on potential fire spread behavior. As modern weather forecasts include temperature and relative humidity predictions, there may already be sufficient information available to develop a structural fire danger rating system. Such a system may include the following steps: (1 Record weather forecasts and actual temperature and relative humidity inside and outside selected structures; (2 Develop a meteorology-data-based model to predict indoor relative humidity levels; (3 Perform controlled drying chamber experiments involving typical hygroscopic fire fuel; (4 Compare the results to the recorded values in selected structures; and (5 Develop the risk model involving the results from drying chamber experiments, weather forecasts, and separation between structures. Knowledge about the structures at risk and their use is also important. The benefits of an automated fire danger rating system would be that the society can better plan for potentially severe cold-climate fires and thereby limit the negative impacts of such fires.

  12. The Leeds Evaluation of Efficacy of Detoxification Study (LEEDS project: An open-label pragmatic randomised control trial comparing the efficacy of differing therapeutic agents for primary care detoxification from either street heroin or methadone [ISRCTN07752728

    Directory of Open Access Journals (Sweden)

    Sheard Laura

    2004-04-01

    Full Text Available Abstract Background Heroin is a synthetic opioid with an extensive illicit market leading to large numbers of people becoming addicted. Heroin users often present to community treatment services requesting detoxification and in the UK various agents are used to control symptoms of withdrawal. Dissatisfaction with methadone detoxification 8 has lead to the use of clonidine, lofexidine, buprenorphine and dihydrocodeine; however, there remains limited evaluative research. In Leeds, a city of 700,000 people in the North of England, dihydrocodeine is the detoxification agent of choice. Sublingual buprenorphine, however, is being introduced. The comparative value of these two drugs for helping people successfully and comfortably withdraw from heroin has never been compared in a randomised trial. Additionally, there is a paucity of research evaluating interventions among drug users in the primary care setting. This study seeks to address this by randomising drug users presenting in primary care to receive either dihydrocodeine or buprenorphine. Methods/design The Leeds Evaluation of Efficacy of Detoxification Study (LEEDS project is a pragmatic randomised trial which will compare the open use of buprenorphine with dihydrocodeine for illicit opiate detoxification, in the UK primary care setting. The LEEDS project will involve consenting adults and will be run in specialist general practice surgeries throughout Leeds. The primary outcome will be the results of a urine opiate screening at the end of the detoxification regimen. Adverse effects and limited data to three and six months will be acquired.

  13. Supplier Performance Evaluation and Rating System (SPEARS)

    International Nuclear Information System (INIS)

    Oged, M.; Warner, D.; Gurbuz, E.

    1993-03-01

    The SSCL Magnet Quality Assurance Department has implemented a Supplier Performance Evaluation and Rating System (SPEARS) to assess supplier performance throughout the development and production stages of the SSCL program. The main objectives of SPEARS are to promote teamwork and recognize performance. This paper examines the current implementation of SPEARS. MSD QA supports the development and production of SSCsuperconducting magnets while implementing the requirements of DOE Order 5700.6C. The MSD QA program is based on the concept of continuous improvement in quality and productivity. The QA program requires that procurement of items and services be controlled to assure conformance to specification. SPEARS has been implemented to meet DOE requirements and to enhance overall confidence in supplier performance. Key elements of SPEARS include supplier evaluation and selection as well as evaluation of furnished quality through source inspection, audit, and receipt inspection. These elements are described in this paper

  14. Supplier Performance Evaluation and Rating System (SPEARS)

    International Nuclear Information System (INIS)

    Oged, M.; Warner, D.G.; Gurbuz, E.

    1994-01-01

    The SSCL Magnet Quality Assurance Department has implemented a Supplier Performance Evaluation and Rating System (SPEARS) to assess supplier performance throughout the development and production stages of the SSCL program. The main objectives of SPEARS are to promote teamwork and recognize performance. This paper examines the current implementation of SPEARS. MSD QA supports the development and production of SSC superconducting magnets while implementing the requirements of DOE Order 5700.6C. The MSD QA program is based on the concept of continuous improvement in quality and productivity. The QA program requires that procurement of items and services be controlled to assure conformance to specification. SPEARS has been implemented to meet DOE requirements and to enhance overall confidence in supplier performance. Key elements of SPEARS include supplier evaluation and selection as well as evaluation of furnished quality through source inspection, audit, and receipt inspection. These elements are described in this paper

  15. Building Green: The Adoption Process of LEED- and Energy Star-Rated Office Buildings

    Science.gov (United States)

    Malkani, Arvin P.

    2012-01-01

    There are opportunities for green building technology in office buildings to produce energy savings and cost efficiencies that can produce a positive economic and environmental impact. In order for these opportunities to be realized, however, decision makers must appreciate the value of green building technology. The objective of this research is…

  16. Darning, doylies and dancing: the work of the Leeds Association of Girls' Clubs (1904-1913).

    Science.gov (United States)

    Jones, Helen M F

    2011-01-01

    The Leeds Association of Girls' Clubs (LAGC) was set up by a group of women, including Hilda Hargrove, Dr Lucy Buckley and Mary and Margaret Harvey, to promote collaboration between the city's girls' clubs. The organisation epitomised women working in partnership whilst reflecting their differing philanthropic and political interests. However LAGC's collaborative approach resulted in liberal consensus which downplayed the significance of girls' working conditions. Throughout the decade LAGC's focus was its annual competitions. These featured utilitarian and decorative handicrafts (darning and doylies) enshrining both frugality and aspiration, alongside dance and drill which channelled girls' vigour. Nevertheless, LAGC's resilience resulted in an organisation which is still in existence.

  17. Liability aspects of home energy-rating systems

    Energy Technology Data Exchange (ETDEWEB)

    Hendrickson, P.L.

    1983-10-01

    Liability aspects of home energy rating systems are discussed. An introduction to the rating system concept, including types of rating systems, implementation efforts to date, and possible groups to conduct ratings, is also included. The home energy rating system concept involves the periodic rating of the energy efficiency of residential buildings. The rating can provide a relative indication of a home's energy efficiency and also a quantitative estimate of consumption, fuel cost, or both. Primary attention is given to liability issues associated with developing and performing ratings. Secondary attention is given to possible liability associated with misuse of a rating once it has been performed.

  18. LEED AND THE DESIGN/BUILD EXPERIENCE: A SHELTER FOR HOMELESS FAMILIES RETURNING TO POST-KATRINA NEW ORLEANS.

    Directory of Open Access Journals (Sweden)

    Stephen Verderber

    2011-03-01

    Full Text Available Hurricane Katrina displaced nearly one million citizens from the New Orleans metro region in 2005. Five years after the catastrophe, in August of 2010, more than 150,000 citizens remained scattered across the United States. Katrina was the largest Diaspora in the nation’s history. The number of homes damaged or destroyed by Katrina’s devastation numbered more than 125,000. An award-winning case study is presented of a unique partnership forged between academia, a local social service agency, professional architectural and engineering firms, and a national humanitarian aid organization whose mission is to provide affordable housing for homeless persons in transition. This collaboration resulted in a sustainable design/build project that originated in a research-based university design studio. The facility is a 38-bed family shelter for homeless mothers and their children seeking to rebuild their lives in post-Katrina New Orleans. The site for this 4,400 facility did not flood when the city’s federally built levee system failed in 2005. This case study is presented from its inception, to programming and design, construction, occupancy, and the postoccupancy assessment of the completed building. This facility is the first LEED certified (Silver building in New Orleans. Project limitations, lessons learned, and recommendations for future initiatives of this type are discussed, particularly in the context of any inner urban community coping with the aftermath of an urban disaster.

  19. Characterization of Si(112) and In/Si(112) studied by SPA-LEED

    Energy Technology Data Exchange (ETDEWEB)

    Hoecker, Jan; Speckmann, Moritz; Schmidt, Thomas; Falta, Jens [Institute of Solid State Physics, University of Bremen, 28359 Bremen (Germany)

    2010-07-01

    High index surfaces are of strong interest in todays research because of the possibility to grow low dimensional structures. It has for instance already been shown that the adsorption of Ga can induce the formation of 1D metal chains on Si(112) (cf. Snijders et al., PRB 72, 2005). In this work we investigated the clean Si(112) surface and the adsorption of In on Si(112) to establish an analogy to Ga/Si(112) using spot profile analyzing low energy electron diffraction (SPA-LEED). By means of reciprocal space mapping we determined the bare Si(112) surface to be decomposed into alternating (5512) and (111) facets in [1 anti 10] direction with (2 x 1) and (7 x 7) reconstruction, respectively (cf. Baski et al., Surf. Sci. 392, 1997). With SPA-LEED we were able to observe the decreasing intensity of the facet spots in-situ while depositing In on Si(112) and thus reveal the smoothening of the surface due to the deposition of In. At saturation coverage we found a (3.x1) reconstruction, where x is dependent on the deposition temperature and changes from x=7 at 400 C to x=5 at 500 C. This leads us to the assumption that the reconstruction is not incommensurate but a mixture of (3 x 1) and (4 x 1) building blocks, which is very similar to the super structure of Ga on Si(112).

  20. Towards The Adaptation of Green Building Material Systems to the Egyptian Environment

    OpenAIRE

    Sherif Mohamed Sabry Elattar; Eman Badawy Ahmed

    2014-01-01

    This research briefly reviews the definition and the principles of green architecture, making a comparison between the global green building rating systems in respect to materials only. These systems are the [1, 2]Green Pyramid, BREEAM (Building Research Establishment Environment Assessment Method), [3] LEED (Leadership in Energy and Environmental Design) and the [4] Green Star in the form of Credits %, importance and its Requirements.The research Aims to evaluate the green building material ...

  1. 78 FR 18252 - Prevailing Rate Systems; North American Industry Classification System Based Federal Wage System...

    Science.gov (United States)

    2013-03-26

    ...-AM78 Prevailing Rate Systems; North American Industry Classification System Based Federal Wage System... applicable sections. The Federal Prevailing Rate Advisory Committee, the national labor- management committee... proposing to amend 5 CFR part 532 as follows: PART 532--PREVAILING RATE SYSTEMS 0 1. The authority citation...

  2. Mutation Rates of STR Systems in Danes

    DEFF Research Database (Denmark)

    Andersen, Kim Emil; Bøttcher, Susanne Gammelgaard; Christensen, Susanne

    Danish paternity cases in the period 1999 to 2005 were investigated regarding mutation rates in STR loci. STR-typing was performed by the Applied Biosystems AmplfStr Profiler Plus kit in the period 1999 to early 2005, hereafter named the PP9, and by Applied Biosystems AmplfStr Identifier kit for ...... and kits. Sex and STR locus specific mutation rates were estimated with 95% confidence limits by the method of Clopper and Pearson (1934)....

  3. The two-glass-building in Ratingen. LEED platin for the Coca-Cola headquarter; Das Zwei-Scheiben-Haus in Ratingen. LEED-Platin fuer die Coca-Cola-Zentrale

    Energy Technology Data Exchange (ETDEWEB)

    Zerres, Eberhard

    2011-07-01

    In order to receive the eco-labeled LEED platinum category, a good planning is essential. In the construction of a new administration building in Ratingen (Federal Republic of Germany), many details have been considered up to the use of ecologically unquestionable building materials. Thus, these details were very purposeful.

  4. 13 CFR 120.1015 - Risk Rating System.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Risk Rating System. 120.1015 Section 120.1015 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Risk-Based Lender Oversight Supervision § 120.1015 Risk Rating System. (a) Risk Rating. SBA may assign a Risk Rating...

  5. 78 FR 62616 - Integrated System Power Rates

    Science.gov (United States)

    2013-10-22

    .... James K. McDonald, Vice President for Corporate Operations/Chief Operating Office, Southwestern Power...) 595-6690, jim.mcdonald@swpa.gov . SUPPLEMENTARY INFORMATION: Rate Order No. SWPA-66, which has been... final approval by the Federal Energy Regulatory Commission. Available: In the marketing area of...

  6. 75 FR 1363 - Integrated System Power Rates

    Science.gov (United States)

    2010-01-11

    ... increased. Those customers taking transformation service will be affected by an increase in that rate... Regulation Purchased. With factors defined as follows: RPA = The Customer's specific monthly dollar amount of... formulas provided in Customers' contracts indicate an overrun on Hydro Peaking Power, and investigation...

  7. [Design of Oxygen Saturation, Heart Rate, Respiration Rate Detection System Based on Smartphone of Android Operating System].

    Science.gov (United States)

    Zhu, Mingshan; Zeng, Bixin

    2015-03-01

    In this paper, we designed an oxygen saturation, heart rate, respiration rate monitoring system based on smartphone of android operating system, physiological signal acquired by MSP430 microcontroller and transmitted by Bluetooth module.

  8. “THE LEEDS IDEA”: AN HISTORICAL ACCOUNT OF THE SPONDARTHRITIS CONCEPT

    Directory of Open Access Journals (Sweden)

    J.M.H. Moll

    2011-09-01

    Full Text Available SUMMARY In the 1960s, Professor Verna Wright became increasingly interested in possible relationships between certain seronegative “variants of rheumatoid arthritis”, as they were then generally known. At the Rheumatism Research Unit, a department within the division of medicine at Leeds University, he gathered around him a succession of research workers, whom he inspired to study aspects of these relationships. The focus was on family studies, as it was thought that genetic factors could be important. The striking association previously noted between sacroiliitis or full-blown ankylosing spondylitis and several of these disorders to be studied - e.g., psoriatic arthritis, ulcerative colitis, and the arthritis associated with Crohn’s disease - was to be central for each of these studies. As a provisional collective name for these possibly related conditions, the term “Spondarthritides” was chosen. These were the days before HLA B27, and so the research tools were simply clinical, radiological (for sacroiliitis and serological (for rheumatoid factor. The research programme confirmed not only links between the primary disorders with ankylosing spondylitis, but also links between the disorders themselves. Over subsequent years, the spondarthritis concept (dubbed by some “The Leeds Idea” has gained further strength from HLA studies internationally. And membership of the group of conditions fulfilling spondarthritis criteria has grown substantially. It is hoped that this now consolidated framework of spondylitis-related entities will pave the way for further research, with exciting prospects of gene-based prevention and/or cure through the increasing sophistication of molecular biology. Key words: Seronegative spondarthritides, psoriatic arthritis, ankylosing spndylitis

  9. A fire danger rating system for Hawaii

    Science.gov (United States)

    Robert E. Burgan; Francis M. Fujioka; George H. Hirata

    1974-01-01

    Extremes in rainfall on the Hawaiian Islands make it difficult to judge forest fire danger conditions. The use of an automatic data collection and computer processing system helps to monitor the problem.

  10. AIR TICKETS RATES MONITORING: INFORMATION SYSTEM DEVELOPMENT

    Directory of Open Access Journals (Sweden)

    Oleg Smirnov

    2015-05-01

    Full Text Available In the article conduct analysis of preconditions of air tickets fares dynamics. Monitoring informational system formation in aim of public regulation of air transport on base of an assessment of the current state and development prospects of Russian civil aviation, and formed the conceptual basis for information system architecture at the levels of the presentation layer, business-logic and data access layer.

  11. High Repetition Rate Thermometry System And Method

    KAUST Repository

    Chrystie, Robin

    2015-05-14

    A system and method for rapid thermometry using intrapulse spectroscopy can include a laser for propagating pulses of electromagnetic radiation to a region. Each of the pulses can be chirped. The pulses from the region can be detected. An intrapulse absorbance spectrum can be determined from the pulses. An instantaneous temperature of the region based on the intrapulse absorbance spectrum can be determined.

  12. High Repetition Rate Thermometry System And Method

    KAUST Repository

    Chrystie, Robin; Farooq, Aamir

    2015-01-01

    A system and method for rapid thermometry using intrapulse spectroscopy can include a laser for propagating pulses of electromagnetic radiation to a region. Each of the pulses can be chirped. The pulses from the region can be detected. An intrapulse absorbance spectrum can be determined from the pulses. An instantaneous temperature of the region based on the intrapulse absorbance spectrum can be determined.

  13. Constraints on relaxation rates for N-level quantum systems

    International Nuclear Information System (INIS)

    Schirmer, S.G.; Solomon, A.I.

    2004-01-01

    We study the constraints imposed on the population and phase relaxation rates by the physical requirement of completely positive evolution for open N-level systems. The Lindblad operators that govern the evolution of the system are expressed in terms of observable relaxation rates, explicit formulas for the decoherence rates due to population relaxation are derived, and it is shown that there are additional, nontrivial constraints on the pure dephasing rates for N>2. Explicit, experimentally testable inequality constraints for the decoherence rates are derived for three- and four-level systems, and the implications of the results are discussed for generic ladder, Λ, and V systems and transitions between degenerate energy levels

  14. Rate My Information Systems Professor: Exploring the Factors That Influence Student Ratings

    Science.gov (United States)

    Sena, Mark; Crable, Elaine

    2017-01-01

    Based on 820 entries on Ratemyprofessors.com, we explore whether information systems course ratings differ from those in marketing or management courses, whether lower level course ratings differ from those in senior or graduate level courses, whether course ratings differ between genders, and whether perceived course difficulty impacts course…

  15. Conservative interacting particles system with anomalous rate of ergodicity

    OpenAIRE

    Brzeźniak, Zdzislaw; Flandoli, Franco; Neklyudov, Misha; Zegarliński, Boguslaw

    2010-01-01

    We analyze certain conservative interacting particle system and establish ergodicity of the system for a family of invariant measures. Furthermore, we show that convergence rate to equilibrium is exponential. This result is of interest because it presents counterexample to the standard assumption of physicists that conservative system implies polynomial rate of convergence.

  16. Two-Stage Variable Sample-Rate Conversion System

    Science.gov (United States)

    Tkacenko, Andre

    2009-01-01

    A two-stage variable sample-rate conversion (SRC) system has been pro posed as part of a digital signal-processing system in a digital com munication radio receiver that utilizes a variety of data rates. The proposed system would be used as an interface between (1) an analog- todigital converter used in the front end of the receiver to sample an intermediatefrequency signal at a fixed input rate and (2) digita lly implemented tracking loops in subsequent stages that operate at v arious sample rates that are generally lower than the input sample r ate. This Two-Stage System would be capable of converting from an input sample rate to a desired lower output sample rate that could be var iable and not necessarily a rational fraction of the input rate.

  17. Introduction to State Estimation of High-Rate System Dynamics.

    Science.gov (United States)

    Hong, Jonathan; Laflamme, Simon; Dodson, Jacob; Joyce, Bryan

    2018-01-13

    Engineering systems experiencing high-rate dynamic events, including airbags, debris detection, and active blast protection systems, could benefit from real-time observability for enhanced performance. However, the task of high-rate state estimation is challenging, in particular for real-time applications where the rate of the observer's convergence needs to be in the microsecond range. This paper identifies the challenges of state estimation of high-rate systems and discusses the fundamental characteristics of high-rate systems. A survey of applications and methods for estimators that have the potential to produce accurate estimations for a complex system experiencing highly dynamic events is presented. It is argued that adaptive observers are important to this research. In particular, adaptive data-driven observers are advantageous due to their adaptability and lack of dependence on the system model.

  18. Hazard rate for a two-channel protective system subject to a high demand rate

    International Nuclear Information System (INIS)

    Oliveira, L.F.; Youngblood, R.; Melo, P.F.F.

    1989-01-01

    A basic figure of merit associated with a protective system for an industrial plant is the number of accidents expected to occur in the plant within a given period of time, with the system installed. By definition, in a plant equipped with a protective system, an accident can only happen if an initiating event (a demand) occurs while the protective system is unavailable, that is, while it is in one of its possible failed states. This means that the hazard rate or accident frequency depends on the demand rate and on the unavailability of the protective systems. It has long been recognized that the demand rate influences the unavailability of the protective system, and practical expressions incorporating that effect have been developed for single-channel (Lees, 1982) and multi-channel (Kumamoto and Henley 1978) protective systems. The effect has also been incorporated into a Markovian treatment of a plant protection system (Papazoglou and Cho, 1985). In a previous paper (Oliveira and Netto, 1987) a Markovian approach was used to derive analytical expressions for the evaluation of the plant hazard rate for a single-channel protective system, properly accounting for the effects of the demand and the repair rates. In this paper the authors present an extension of that model to the case of a plant equipped with a two-channel protective system

  19. The order and volume fill rates in inventory control systems

    DEFF Research Database (Denmark)

    Thorstenson, Anders; Larsen, Christian

    2011-01-01

    This paper differentiates between an order (line) fill rate and a volume fill rate and specifies their performance for different inventory control systems. When the focus is on filling complete customer orders rather than total quantities the order fill rate would be the preferred service level m...

  20. Rate-distortion in Closed-Loop LTI Systems

    DEFF Research Database (Denmark)

    Silva, Eduardo; Derpich, Milan; Østergaard, Jan

    2013-01-01

    We consider a networked LTI system subject to an average data-rate constraint in the feedback path.We provide upper bounds to the minimal source coding rate required to achieve mean square stability and a desired level of performance. In the quadratic Gaussian case, an almost complete rate...

  1. PLEASE: The Python Low-energy Electron Analysis SuitE – Enabling Rapid Analysis of LEEM and LEED Data

    Directory of Open Access Journals (Sweden)

    Maxwell Grady

    2018-02-01

    Full Text Available PLEASE, the Python Low-energy Electron Analysis SuitE, provides an open source and cross-platform graphical user interface (GUI for rapid analysis and visualization of low energy electron microscopy (LEEM data sets. LEEM and the associated technique, selected area micro-spot low energy electron diffraction (μ-LEED, are powerful tools for analysis of the surface structure for many novel materials. Specifically, these tools are uniquely suited for the characterization of two-dimensional materials. PLEASE offers a user-friendly point-and-click method for extracting intensity-voltage curves from LEEM and LEED data sets. Analysis of these curves provides insight into the atomic structure of the target material surface with unparalleled resolution.

  2. In the spotlight. Interview with Kenneth Lee, Health Economist, University of Leeds, U.K.. Interview by Johannes Stoelwinder.

    Science.gov (United States)

    Lee, K

    1984-01-01

    Ken Lee appointed to the staff of the Nuffield Centre, University of Leeds, as Lecturer in Health Economics in 1970. He is now Senior Lecturer and Director of the Master's Programme in Health Service Studies. His main teaching interests are in health planning and health economics, and he has carried out research and written extensively on approaches to health economics, health planning and management, care of the elderly, primary health care, health financing, and emergency health services.

  3. Translating research into practice in Leeds and Bradford (TRiPLaB: a protocol for a programme of research

    Directory of Open Access Journals (Sweden)

    Bibby John

    2010-05-01

    Full Text Available Abstract Background The National Institute for Health Research (NIHR has funded nine Collaborations for Leadership in Applied Health Research and Care (CLAHRCs. Each CLAHRC is a partnership between higher education institutions (HEIs and the NHS in nine UK regional health economies. The CLAHRC for Leeds, York, and Bradford comprises two 'research themes' and three 'implementation themes.' One of these implementation themes is Translating Research into Practice in Leeds and Bradford (TRiPLaB. TRiPLaB aims to develop, implement, and evaluate methods for inducing and sustaining the uptake of research knowledge into practice in order to improve the quality of health services for the people of Leeds and Bradford. Methods TRiPLaB is built around a three-stage, sequential, approach using separate, longitudinal case studies conducted with collaborating NHS organisations, TRiPLaB will select robust innovations to implement, conduct a theory-informed exploration of the local context using a variety of data collection and analytic methods, and synthesise the information collected to identify the key factors influencing the uptake and adoption of targeted innovations. This synthesis will inform the development of tailored, multifaceted, interventions designed to increase the translation of research findings into practice. Mixed research methods, including time series analysis, quasi-experimental comparison, and qualitative process evaluation, will be used to evaluate the impact of the implementation strategies deployed. Conclusion TRiPLaB is a theory-informed, systematic, mixed methods approach to developing and evaluating tailored implementation strategies aimed at increasing the translation of research-based findings into practice in one UK health economy. Through active collaboration with its local NHS, TRiPLaB aims to improve the quality of health services for the people of Leeds and Bradford and to contribute to research knowledge regarding the

  4. Proceedings of the International Workshop on Computational Electronics Held at Leeds University (United Kingdom) on August 11-13 1993

    Science.gov (United States)

    1993-08-01

    Drury , Sponsored by UK SERC and MIA-COM (USA). Apart from any fair dealing for the purposes of research or private study, or criticism or review, as...field effect 128 transistors R Drury , R E Miles and C M Snowden, University of Leeds Poster Session II Determination of diffusion coefficients and...V V V y V V V Device simulation by means of a direct solution of the coupled Poisson/Boltzmann Transport enuations Conor J. Donnelly and Colin Lyden

  5. Position paper -- Tank ventilation system design air flow rates

    International Nuclear Information System (INIS)

    Goolsby, G.K.

    1995-01-01

    The purpose of this paper is to document a project position on required ventilation system design air flow rates for the waste storage tanks currently being designed by project W-236A, the Multi-Function Waste Tank Facility (MWTF). The Title 1 design primary tank heat removal system consists of two systems: a primary tank vapor space ventilation system; and an annulus ventilation system. At the conclusion of Title 1 design, air flow rates for the primary and annulus ventilation systems were 960 scfm and 4,400 scfm, respectively, per tank. These design flow rates were capable of removing 1,250,000 Btu/hr from each tank. However, recently completed and ongoing studies have resulted in a design change to reduce the extreme case heat load to 700,000 Btu/hr. This revision of the extreme case heat load, coupled with results of scale model evaporative testing performed by WHC Thermal Hydraulics, allow for a reduction of the design air flow rates for both primary and annulus ventilation systems. Based on the preceding discussion, ICF Kaiser Hanford Co. concludes that the design should incorporate the following design air flow rates: Primary ventilation system--500 scfm maximum and Annulus ventilation system--1,100 scfm maximum. In addition, the minimum air flow rates in the primary and annulus ventilation systems will be investigated during Title 2 design. The results of the Title 2 investigation will determine the range of available temperature control using variable air flows to both ventilation systems

  6. Analysis of secondary electron emission for conducting materials using 4-grid LEED/AES optics

    International Nuclear Information System (INIS)

    Patino, M I; Wirz, R E; Raitses, Y; Koel, B E

    2015-01-01

    A facility utilizing 4-grid optics for LEED/AES (low energy electron diffraction/Auger electron spectroscopy) was developed to measure the total secondary electron yield and secondary electron energy distribution function for conducting materials. The facility and experimental procedure were validated with measurements of 50–500 eV primary electrons impacting graphite. The total yield was calculated from measurements of the secondary electron current (i) from the sample and (ii) from the collection assembly, by biasing each surface. Secondary electron yield results from both methods agreed well with each other and were within the spread of previous results for the total yield from graphite. Additionally, measurements of the energy distribution function of secondary electrons from graphite are provided for a wider range of incident electron energies. These results can be used in modeling plasma-wall interactions in plasmas bounded by graphite walls, such as are found in plasma thrusters, and divertors and limiters of magnetic fusion devices. (paper)

  7. Office layout affecting privacy, interaction, and acoustic quality in LEED-certified buildings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young S. [School of Planning, Design, and Construction, Michigan State University, East Lansing, MI 48823 (United States)

    2010-07-15

    The study investigated differences in worker satisfaction and perceived job performance regarding privacy, interaction, and acoustic quality issues in personal workspaces between five office types in LEED-certified buildings. It finds that people in high cubicles showed significantly lower satisfaction and job performance in relation to visual privacy and interaction with co-workers than both enclosed private and enclosed shared office types. They also showed significantly lower satisfaction with noise level and sound privacy and lower job performance perceived by acoustic quality than enclosed private, enclosed shared, and bullpen types. The bullpen type, open-plan office without partitions, presented significantly higher satisfaction with noise level and higher performance perceived by acoustic quality than both high and low cubicles. Considering the bullpen type also showed higher satisfaction with sound privacy than the high cubicle type, high partitions don't seem to contribute to creating workspaces where people can have a secure conversation. The bullpen type didn't show any difference from the enclosed shared type in all privacy, interaction, and acoustic quality questions, indicating it may be a good option for a small office space instead of the enclosed shared type. (author)

  8. Validation study of the Leeds Dyspepsia Questionnaire in a multi-ethnic Asian population.

    Science.gov (United States)

    Mahadeva, Sanjiv; Chan, Wah-Kheong; Mohazmi, Mohammed; Sujarita, Ramanujam; Goh, Khean-Lee

    2011-11-01

    Outcome measures for clinical trials in dyspepsia require an assessment of symptom response. There is a lack of validated instruments assessing dyspepsia symptoms in the Asian region. We aimed to translate and validate the Leeds Dyspepsia Questionnaire (LDQ) in a multi-ethnic Asian population. A Malay and culturally adapted English version of the LDQ were developed according to established protocols. Psychometric evaluation was performed by assessing the validity, internal consistency, test-retest reliability and responsiveness of the instruments in both primary and secondary care patients. Between April and September 2010, both Malay (n=166) and Malaysian English (n=154) versions were assessed in primary and secondary care patients. Both language versions were found to be reliable (internal consistency was 0.80 and 0.74 (Cronbach's α) for Malay and English, respectively; spearman's correlation coefficient for test-retest reliability was 0.98 for both versions), valid (area under receiver operating curve for accuracy of diagnosing dyspepsia was 0.71 and 0.77 for Malay and English versions, respectively), discriminative (median LDQ score discriminated between primary and secondary care patients in Malay (11.0 vs 20.0, PAsian population with dyspepsia. © 2011 Journal of Gastroenterology and Hepatology Foundation and Blackwell Publishing Asia Pty Ltd.

  9. LEED, Its Efficacy and Fallacy in a Regional Context—An Urban Heat Island Case in California

    Directory of Open Access Journals (Sweden)

    Min Ho Shin

    2017-09-01

    Full Text Available The use of energy in the building sector has increased rapidly over the past two decades. Accordingly, various building assessment methods have developed in green building practices. However, the questions still remain in regard to how positively green buildings affect regional surroundings. This study investigates the possible relationship between LEED-certified buildings and urban heat island effect. Using GIS with spatial regression, the study found that constructing an LEED building in a 30-m boundary could possibly lower the temperature of the surrounding environment by 0.35 °C. Also, having a higher certification level, such as Gold or Platinum, increased the lowering effect by 0.48 °C, while a lower certification level, such as Certified or Silver, had a lowering effect of 0.26 °C. Although LEED has gained a substantial amount of interest and skepticism at the same time, the study results could be a potential sign that the Sustainable Sites Credits or energy-efficient materials play a positive role in lowering the temperature.

  10. Beneficios económicos de la certificación LEED. Edificio centro Ático: caso de estudio

    Directory of Open Access Journals (Sweden)

    Óscar Ribero

    Full Text Available En el presente artículo se estudian los beneficios económicos de la aplicación del programa de certificación de construcciones sostenibles LEED, en el Edificio Centro Ático situado en Bogotá - Colombia. Inicialmente, se determinan los consumos de agua y energía eléctrica, y los costos de construcción y operación del edificio bajo su diseño original (construido sin tener en cuenta los parámetros establecidos por LEED. Seguido a esto se plantean estrategias para lograr que el edificio Centro Ático alcance la certificación LEED GOLD New Construction V3 2009 y se calculan los incrementos económicos asociados a éstas. Así mismo, se calculan los nuevos consumos de agua y energía eléctrica bajo la aplicación de dichas estrategias (diseño modificado y sus correspondientes costos de operación. Finalmente, se determinan los indicadores de bondad económica de la inversión mediante un análisis de flujo de caja.

  11. The order and volume fill rates in inventory control systems

    DEFF Research Database (Denmark)

    Thorstenson, Anders; Larsen, Christian

    2011-01-01

    This paper differentiates between an order (line) fill rate and a volume fill rate and specifies their performance for different inventory control systems. When the focus is on filling complete customer orders rather than total quantities the order fill rate would be the preferred service level...... measure. The main result shows how the order and volume fill rates are related in magnitude. Earlier results derived for a single-item, single-stage, continuous review inventory system with backordering and constant lead times controlled by a base-stock policy are extended in different directions...

  12. Fill Rates of Single-Stage and Multistage Supply Systems

    OpenAIRE

    Matthew J. Sobel

    2004-01-01

    A supply system's fill rate is the fraction of demand that is met from on-hand inventory. This paper presents formulas for the fill rate of periodic review supply systems that use base-stock-level policies. The first part of the paper contains fill-rate formulas for a single-stage system and general distributions of demand. When demand is normally distributed, an exact expression uses only the standard normal distribution and density functions, and a good approximation uses only the standard ...

  13. Reduction of Large Dynamical Systems by Minimization of Evolution Rate

    Science.gov (United States)

    Girimaji, Sharath S.

    1999-01-01

    Reduction of a large system of equations to a lower-dimensional system of similar dynamics is investigated. For dynamical systems with disparate timescales, a criterion for determining redundant dimensions and a general reduction method based on the minimization of evolution rate are proposed.

  14. State estimation for networked control systems using fixed data rates

    Science.gov (United States)

    Liu, Qing-Quan; Jin, Fang

    2017-07-01

    This paper investigates state estimation for linear time-invariant systems where sensors and controllers are geographically separated and connected via a bandwidth-limited and errorless communication channel with the fixed data rate. All plant states are quantised, coded and converted together into a codeword in our quantisation and coding scheme. We present necessary and sufficient conditions on the fixed data rate for observability of such systems, and further develop the data-rate theorem. It is shown in our results that there exists a quantisation and coding scheme to ensure observability of the system if the fixed data rate is larger than the lower bound given, which is less conservative than the one in the literature. Furthermore, we also examine the role that the disturbances have on the state estimation problem in the case with data-rate limitations. Illustrative examples are given to demonstrate the effectiveness of the proposed method.

  15. 76 FR 50726 - Integrated System Power Rates: Correction

    Science.gov (United States)

    2011-08-16

    ... DEPARTMENT OF ENERGY Southwestern Power Administration Integrated System Power Rates: Correction AGENCY: Southwestern Power Administration, DOE. ACTION: Notice of public review and comment; Correction... date listed for the combined Public Information and Comment Forum (Forum) was erroneously listed in the...

  16. Quality Rating and Improvement System State Evaluations and Research

    Science.gov (United States)

    Ferguson, Daniel

    2016-01-01

    A quality rating and improvement system (QRIS) is a method used by states and local jurisdictions to assess the level of quality of child care and early education programs, improve quality, and convey quality ratings to parents and other consumers. A typical QRIS incorporates the following components: quality standards for participating providers;…

  17. Performance evaluation of a center pivot variable rate irrigation system

    Science.gov (United States)

    Variable Rate Irrigation (VRI) for center pivots offers potential to match specific application rates to non-uniform soil conditions along the length of the lateral. The benefit of such systems is influenced by the areal extent of these variations and the smallest scale to which the irrigation syste...

  18. Labeling and Rating Systems: Greater Access or Censorship?

    Science.gov (United States)

    Martin, Ann M.

    2015-01-01

    This article asks the question: How well versed are school librarians on issues related to labeling and rating systems? As school librarians continue to design and implement resource location schemes to assist patrons, they must recognize the difference between using labels to create interest in books or implementing labeling and rating systems…

  19. Carbon Footprint of Housing in the Leeds City Region - A Best Practice Scenario Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, John; Dawkins, Elena (Stockholm Environment Inst. (Sweden))|(Univ. of York, Heslington, York YO10 5DD (United Kingdom))

    2008-06-15

    The Stockholm Environment Institute (SEI) was commissioned by the Environment Agency to carry out a carbon footprint analysis of the housing sector, using the Leeds City Region (LCR) as an example. The aim was to determine our ability to meet the 80 per cent by 2050 challenge of energy efficiency in the housing sector. The study relates specifically to LCR but its findings will help any planning and development teams make the right decisions and gain the resources necessary to meet carbon budgets at regional and local levels. With a growing population and an additional 263,000 housing units to be built within LCR by 2026, the housing sector would need to reduce its expected total carbon dioxide emissions by 38 million tonnes between 2010 and 2026 to be on track for 80 per cent savings in 2050. The report outlines the most detailed analysis to date of the required measures to deliver a growth-based regional housing strategy, alongside reducing carbon emissions. If the city region's new and existing housing is to attain the levels of energy efficiency necessary to deliver these carbon savings, big changes will be required in the way we build, maintain and run our homes over the next 20 years. There are pockets of good practice already in the region and the study shows that by combining innovative measures on construction standards, improvements to existing housing, low and zero carbon technologies and changing behaviour of householders, LCR can achieve the necessary savings to meet its carbon budget

  20. Social determinants of male health: a case study of Leeds, UK.

    Science.gov (United States)

    White, Alan; Seims, Amanda; Cameron, Ian; Taylor, Tim

    2018-01-19

    The social determinants of health have a disproportionate impact on mortality in men. A study into the state of health of the male population in Leeds was undertaken to guide public health commissioning decisions. This paper reports on the data relating to the social lives of men. A cross-sectional study was undertaken, comprising descriptive analysis of data relating to educational attainment, housing, employment (including benefit claimants), marital status and relationships. Data was considered for the whole city and localised at the Middle Super Output Area (MSOA) level and mapped against the Index of Deprivation. Boys' educational attainment was found to be lagging behind girls' from their earliest assessments (Early Years Foundation Stage Profile, 46% vs. 60%, P = 0.00) to GCSEs (53% vs. 63%, P = 0.00), leaving many men with no qualifications. There were 68% more men than women identified as being unemployed, with more men claiming benefits. Men living in social housing are more likely to be housed in high-rise flats. Almost 50% of men aged 16-64 are single, with 2254 lone fathers. There appears to be a lack of sex/gender analysis of current cross city data. In areas of deprivation a complex picture of multiple social problems emerges, with marked gender differences in the social determinants of health, with males seeming to be more negatively affected. There is a need for more focused planning for reaching out and targeting boys and men in the most deprived inner city areas, so that greater efficiency in service delivery can be obtained.

  1. Strategic energy planning within local authorities in the UK: A study of the city of Leeds

    International Nuclear Information System (INIS)

    Bale, Catherine S.E.; Foxon, Timothy J.; Hannon, Matthew J.; Gale, William F.

    2012-01-01

    This paper considers the development of a strategic energy body in a local authority in the UK and looks at the perceived need for, and possible roles of, such a body. Historically, energy provision and management has not usually been a strategic priority for UK local authorities. Yet energy considerations are implicit in key local authority responsibilities such as transport, waste management, planning, and the provision of housing services. In addition, recent UK central government policies support the move to localism and provide incentives for low-carbon energy generation. A study was undertaken to assess the potential (including both the perceived benefits and actual capacity to deliver) for Leeds City Council to develop a strategic body to execute delivery of city-level energy decision-making. We examine the perceived benefits to a range of main stakeholders, using data drawn from interviews with managers responsible for low-carbon and renewable energy projects across the city. Through participant observation we explore the capacity of a local authority to deliver a strategic energy body, and we briefly examine the possible forms of delivery. We conclude with recommendations for national policy that would enable the development of strategic energy bodies across local governments in the UK. - Highlights: ► Strategic energy planning is currently not a priority for UK local authorities. ► We present an empirical study of strategic energy planning in local authorities. ► Results from stakeholder interviews suggest support for a strategic energy body. ► We identify the capacity barriers to implementing a strategic energy body. ► We make recommendations for ways forward and support needed from national policy.

  2. Environmental Assessment Methodologies for Commercial Buildings: An Elicitation Study of U.S. Building Professionals’ Beliefs on Leadership in Energy and Environmental Design (LEED

    Directory of Open Access Journals (Sweden)

    Jasmin Kientzel

    2011-12-01

    Full Text Available Voluntary environmental programs (VEPs have become increasingly popular around the world to address energy efficiency issues that mandatory building codes have not been able to tackle. Even though the utility of voluntary schemes is widely debated, they have become a de facto reality for many professionals in the building and construction sector. One topic that is neglected, however, in both academic and policy discussions, relates to how professionals (architects, engineers, real estate developers, etc. perceive the rise of voluntary rating schemes. In order to fill this gap in the literature, the present study investigates beliefs underlying adoption behavior regarding one of the most prominent voluntary assessment and certification programs in the U.S. building industry, the Leadership in Energy and Environmental Design (LEED scheme. In this paper, an elicitation study, based on 14 semi-structured interviews with building professionals in the North East of the United States, was conducted to analyze this question. Building on the Reasoned Action Approach, this paper shows that, in addition to more conventional factors such as financial calculations and marketing aspects, the understanding of beliefs held by building professionals offers important insights into their decisions to work with Voluntary Environmental Assessment and Rating Programs.

  3. Determination of cost effective waste management system receipt rates

    International Nuclear Information System (INIS)

    McKee, R.W.; Huber, H.D.

    1991-01-01

    A comprehensive logistics and cost analysis has been carried out to determine if there are potential benefits to the high-level waste management system for receipt rates other than the current 3,000 MTU/yr design-basis receipt rate. The scope of the analysis includes both a Repository-Only System and a Storage-Only or Basic MRS System. To allow for current uncertainties in facility startup scheduling, cases considering repository startup dates of 2010 and 2015 and MRS startup dates of 1998 and three years prior to the repository have been evaluated. Receipt rates ranging from 1,500 to 6,000 MTU/yr have been considered for both the MRS and the repository. Higher receipt rates appear to be economically justified for both the repository and an MRS. For a repository-only system, minimum costs are found at a repository receipt rate of 6,000 MTU/yr. When a storage-only MRS is included in the system, minimum system costs are also achieved at a repository receipt rate of 6,000 MTU/yr. However, the MRS receipt rate for minimum system costs depends on the MRS startup date and ranges from 3,500 to 6,000 MTU/yr. With a 1998 MRS and a 2010 repository, the added cost of providing the MRS is offset by at-reactor storage cost reductions and the total system cost of $10.0 billion is virtually the same as for the repository-only system

  4. Determination of cost effective waste management system receipt rates

    International Nuclear Information System (INIS)

    McKee, R.W.; Huber, H.D.

    1991-01-01

    A comprehensive logistics and cost analysis has been carried out to determine if there are potential benefits to the high-level waste management system for receipt rates other than the current 3000 MTU/yr design-basis. The analysis includes both a Repository-Only System and a Storage-Only System. Repository startup dates of 2010 and 2015 and MRS startup dates of 1988 and three years prior to the repository have been evaluated. Receipt rates ranging from 1,500 to 6, 000 MTU/yr have been considered. Higher receipt rates appear to be economically justified, for either system, minimum costs are found at a repository receipt rate of 6000 MTU/yr. However, the MRS receipt rate for minimum system costs depends on the MRS startup date. With a 1988 MRS and a 2010 repository, the added cost of providing the MRS is offset by at-reactor storage cost reductions and the total system cost of $10.0 billion is virtually the same as for the repository- only system. 9 refs., 8 figs., 3 tabs

  5. A zero-sum monetary system, interest rates, and implications

    OpenAIRE

    Hanley, Brian P.

    2015-01-01

    To the knowledge of the author, this is the first time it has been shown that interest rates that are extremely high by modern standards (100% and higher) are necessary within a zero-sum monetary system, and not just driven by greed. Extreme interest rates that appeared in various places and times reinforce the idea that hard money may have contributed to high rates of interest. Here a model is presented that examines the interest rate required to succeed as an investor in a zero-sum fixed qu...

  6. The order and volume fill rates in inventory control systems

    DEFF Research Database (Denmark)

    Thorstenson, Anders; Larsen, Christian

    2014-01-01

    This paper differentiates between an order (line) fill rate and a volume fill rate and specifies their performance for different inventory control systems. When the focus is on filling complete customer orders rather than total demanded quantity the order fill rate would be the preferred service...... level measure. The main result shows how the order and volume fill rates are related in magnitude. Earlier results derived for a single-item, single-stage, continuous review inventory system with backordering and constant lead times controlled by a base-stock policy are extended in different directions...... extensions consider more general inventory control review policies with backordering, as well as some relations between service measures. A particularly important result in the paper concerns an alternative service measure, the customer order fill rate, and shows how this measure always exceeds the other two...

  7. A system approach to high quality picture-rate conversion

    NARCIS (Netherlands)

    Bartels, C.L.L.; Cordes, C.N.; Riemens, B.; Haan, de G.

    2010-01-01

    Various techniques have been implemented to improve the motion portrayal of flat-panel displays, of which the widespread introduction of motion-compensated picture-rate conversion systems is an essential part. However, a careful design of such systems is critical as they have the potential to

  8. Positron imaging system with improved count rate and tomographic capability

    International Nuclear Information System (INIS)

    1979-01-01

    A system with improved count rate capability for detecting the radioactive distribution of positron events within an organ of interest in a living subject is described. Objects of the invention include improving the scintillation crystal and pulse processing electronics, avoiding the limitations of collimators and provide an Arger camera positron imaging system that avoids the use of collimators. (U.K.)

  9. Sustainable systems rating program: Marketing ``Green`` Building in Austin, Texas

    Energy Technology Data Exchange (ETDEWEB)

    1991-12-01

    Four major resource issues for home construction were identified: water, energy, materials, and waste. A systems flow model was then developed that tracked the resource issues through interactive matrices in the areas of sourcing, processing, using, and disposing or recycling. This model served as the basis for a rating system used in an educational and marketing tool called the Eco-Home Guide.

  10. Asymptotic failure rate of a continuously monitored system

    International Nuclear Information System (INIS)

    Grall, A.; Dieulle, L.; Berenguer, C.; Roussignol, M.

    2006-01-01

    This paper deals with a perfectly continuously monitored system which gradually and stochastically deteriorates. The system is renewed by a delayed maintenance operation, which is triggered when the measured deterioration level exceeds an alarm threshold. A mathematical model is developed to study the asymptotic behavior of the reliability function. A procedure is proposed which allows us to identify the asymptotic failure rate of the maintained system. Numerical experiments illustrate the efficiency of the proposed procedure and emphasize the relevance of the asymptotic failure rate as an interesting indicator for the evaluation of the control-limit preventive replacement policy

  11. Asymptotic failure rate of a continuously monitored system

    Energy Technology Data Exchange (ETDEWEB)

    Grall, A. [Institut des Sciences et Technologies de l' Information de Troyes (CNRS-FRE 2732), Equipe de Modelisation et de Surete des Systemes, Universite de Technologie de Troyes, 12 rue Marie Curie, BP 2060, 10010 Troyes Cedex (France)]. E-mail: antoine.grall@utt.fr; Dieulle, L. [Institut des Sciences et Technologies de l' Information de Troyes (CNRS-FRE 2732), Equipe de Modelisation et de Surete des Systemes, Universite de Technologie de Troyes, 12 rue Marie Curie, BP 2060, 10010 Troyes Cedex (France)]. E-mail: laurence.dieulle@utt.fr; Berenguer, C. [Institut des Sciences et Technologies de l' Information de Troyes (CNRS-FRE 2732), Equipe de Modelisation et de Surete des Systemes, Universite de Technologie de Troyes, 12 rue Marie Curie, BP 2060, 10010 Troyes Cedex (France)]. E-mail: christophe.berenguer@utt.fr; Roussignol, M. [Laboratoire d' Analyse et de Mathematiques Appliquees, Universite de Marne la Vallee, 5 bd Descartes, Champs sur Marne, 77454 Marne la Vallee, Cedex 2 (France)]. E-mail: michel.roussignol@univ-mlv.fr

    2006-02-01

    This paper deals with a perfectly continuously monitored system which gradually and stochastically deteriorates. The system is renewed by a delayed maintenance operation, which is triggered when the measured deterioration level exceeds an alarm threshold. A mathematical model is developed to study the asymptotic behavior of the reliability function. A procedure is proposed which allows us to identify the asymptotic failure rate of the maintained system. Numerical experiments illustrate the efficiency of the proposed procedure and emphasize the relevance of the asymptotic failure rate as an interesting indicator for the evaluation of the control-limit preventive replacement policy.

  12. Installation and commissioning of instantaneous dose rate monitoring system

    CERN Document Server

    Iaydjiev, Plamen

    2018-01-01

    INRNE-Sofia was working on the installation and commissioning of new instantaneous dose rate monitoring system for the GIF++ facility at CERN. The final device, containing an 8-channels readout board was designed and tested at the CERN facility during November 2017, in an irradiation campaign supported by the AIDA-2020 TA program. The system is designed to be fully integrated in the GIF++ control system and the data measured are available to the users.

  13. A study of the National Physical Laboratory microdosimetry research programme in collaboration with the University of Leeds

    International Nuclear Information System (INIS)

    Menzel, H.G.

    1987-11-01

    A study of the present programme of work carried out by the National Physical Laboratory and the University of Leeds, has been carried out. The study is based on the use of the tissue-equivalent proportional counter in microdosimetic techniques in radiation protection for monoenergetic neutrons or reference radionuclide neutron sources. This report comments on the programme as a whole and provides recommendations for future research work, taking into account the research programmes carried out at other institutions. It also attempts to summarise the present state of knowledge and experience associated with the application of this technique to radiation fields met in routine radiation protection. (author)

  14. MANAGED FLOAT EXCHANGE RATE SYSTEM: THE SINGAPORE EXPERIENCE

    OpenAIRE

    HOE EE KHOR; JASON LEE; EDWARD ROBINSON; SAKTIANDI SUPAAT

    2007-01-01

    This paper examines the key characteristics of Singapore's exchange rate-centered monetary policy; in particular, its managed float regime which incorporates key features of the basket, band and crawl system popularized by Williamson (1998, 1999). We assess how the flexibility accorded by this framework has been advantageous in facilitating adjustment to various shocks to the economy. A characterization of the countercyclical nature of Singapore's exchange rate policy is also offered, with re...

  15. Development of Wireless System for Containment Integrated Leakage Rate Test

    International Nuclear Information System (INIS)

    Lee, Kwang-Dae; Oh, Eung-Se; Yang, Seung-Ok

    2006-01-01

    The containment system leakage rate should be estimated periodically with reliable test equipment. In light-water reactor nuclear power plants, ANSI/ANS- 56.8 is a basis for determining leakage rates. Two types of data acquisition system, centralized type and networked type, has been used. In centralized type, all sensors are connected directly from sensors in the containment to the measuring equipment outside the building. The other hand, the networked type has several branch chains which connect one group of the network-sensors together. To test leakage rate, more than 20 temperature sensors and 6 humidity sensors, which are different for each plant, should be installed on a specific level in the containment. A wireless technology gives the benefits such as reducing installation efforts, making pretest easy, so it is widely used more and more in the plant monitoring. As the containment system has many kinds of complex barriers to the radio frequency, the radio power and frequency band for better transmission rate as well as the interference by the radio frequency should be considered. The overview of the wireless sensor system for the containment leakage rate test is described here and the test results on Yonggwang unit 4 PWR plant is presented

  16. A new high rate positron lifetime measurement system

    International Nuclear Information System (INIS)

    Bedwell, M.O.; Paulus, T.J.

    1979-01-01

    Positron lifetime measuring system, a technique to perform non-destructive studies on the internal structure of materials, has many components common to those used for nuclear time spectroscopy systems. In each case, a timing coincidence curve is measured for the energy range of interest, and this is accomplished in a typical timing coincidence system. The paper first describes the conventional timing coincidence system, then a new fast timing system is introduced. Comparing to the conventional fast/slow timing system, the fast timing technique offers reduced complexity, lower system cost, and improved high data rate capability. Experimental results show that the FWHM timing resolution ranges from 190 ps for a 1.1 : 1 dynamic range to 337 ps for a 100 : 1 dynamic range of signals with 60 Co. As for the timing resolution as a function of energy, the FWHM resolution for each channel ranges from 124 ps at 1 MeV to 400 ps at 100 keV. Since the excellent timing performance is maintained even at very high input rate, the experimenters can use much more active sources to increase the true coincidence rate and reduce data accumulation time. This method has the added advantage of minimizing long term drift effects since the experiments can be conducted in less time. (Wakatsuki, Y.)

  17. Flexible proportional-rate scheduling for OFDMA system

    KAUST Repository

    Leith, Alex

    2013-10-01

    In this paper, we study the sum-rate maximization algorithms for downlink and uplink orthogonal frequency division multiple access (OFDMA) systems under proportional-rate constraint (PRC) and minimum-rate constraint. We develop a low-complexity weighted channel signal-to-noise ratio (w-SNR)-based ranking scheme for user selection on each subchannel in OFDMA combined with waterfilling (WF) power allocation. Both offline and online optimization algorithms are developed to optimize the SNR weight vector to maximize the sum rate while satisfying several constraints, such as PRC. The offline weight optimization technique relies on the analytical throughput results developed in this paper, and the online weight adaptation method tracks the user rates and meets the PRC using a subgradient search. Furthermore, we introduce a novel SNR operating region test to enhance the multiuser diversity gain and the sum rate. The proposed schemes have a low complexity, which is linear to the numbers of users and subchannels. Simulation results verify the accuracy of the developed analytical rates and fairness formulas, and show that the proposed w-SNR schemes can achieve higher sum rates than several benchmark schemes that provide the PRC with either short-term or long-term fairness. © 2013 IEEE. © 2013 ESO.

  18. Flexible proportional-rate scheduling for OFDMA system

    KAUST Repository

    Leith, Alex; Alouini, Mohamed-Slim; Kim, Dongin; (Sherman) Shen X., Xuemin; Wu, Zhiqiang

    2013-01-01

    In this paper, we study the sum-rate maximization algorithms for downlink and uplink orthogonal frequency division multiple access (OFDMA) systems under proportional-rate constraint (PRC) and minimum-rate constraint. We develop a low-complexity weighted channel signal-to-noise ratio (w-SNR)-based ranking scheme for user selection on each subchannel in OFDMA combined with waterfilling (WF) power allocation. Both offline and online optimization algorithms are developed to optimize the SNR weight vector to maximize the sum rate while satisfying several constraints, such as PRC. The offline weight optimization technique relies on the analytical throughput results developed in this paper, and the online weight adaptation method tracks the user rates and meets the PRC using a subgradient search. Furthermore, we introduce a novel SNR operating region test to enhance the multiuser diversity gain and the sum rate. The proposed schemes have a low complexity, which is linear to the numbers of users and subchannels. Simulation results verify the accuracy of the developed analytical rates and fairness formulas, and show that the proposed w-SNR schemes can achieve higher sum rates than several benchmark schemes that provide the PRC with either short-term or long-term fairness. © 2013 IEEE. © 2013 ESO.

  19. Eliminating the Effect of Rating Bias on Reputation Systems

    Directory of Open Access Journals (Sweden)

    Leilei Wu

    2018-01-01

    Full Text Available The ongoing rapid development of the e-commercial and interest-base websites makes it more pressing to evaluate objects’ accurate quality before recommendation. The objects’ quality is often calculated based on their historical information, such as selected records or rating scores. Usually high quality products obtain higher average ratings than low quality products regardless of rating biases or errors. However, many empirical cases demonstrate that consumers may be misled by rating scores added by unreliable users or deliberate tampering. In this case, users’ reputation, that is, the ability to rate trustily and precisely, makes a big difference during the evaluation process. Thus, one of the main challenges in designing reputation systems is eliminating the effects of users’ rating bias. To give an objective evaluation of each user’s reputation and uncover an object’s intrinsic quality, we propose an iterative balance (IB method to correct users’ rating biases. Experiments on two datasets show that the IB method is a highly self-consistent and robust algorithm and it can accurately quantify movies’ actual quality and users’ stability of rating. Compared with existing methods, the IB method has higher ability to find the “dark horses,” that is, not so popular yet good movies, in the Academy Awards.

  20. Development of dose rate estimation system for FBR maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Iizawa, Katsuyuki [Japan Nuclear Cycle Development Inst., Tsuruga Head Office, International Cooperation and Technology Development Center, Tsuruga, Fukui (Japan); Takeuchi, Jun; Yoshikawa, Satoru [Hitachi Engineering Company, Ltd., Hitachi, Ibaraki (Japan); Urushihara, Hiroshi [Ibaraki Hitachi Information Service Co., Ltd., Omika, Ibaraki (Japan)

    2001-09-01

    During maintenance activities on the primary sodium cooling system by an FBR Personnel radiation exposure arises mainly from the presence of radioactive corrosion products (CP). A CP behavior analysis code, PSYCHE, and a radiation shielding calculation code, QAD-CG, have been developed and applied to investigate the possible reduction of radiation exposure of workers. In order to make these evaluation methods more accessible to plant engineers, the user interface of the codes has been improved and an integrated system, including visualization of the calculated gamma-ray radiation dose-rate map, has been developed. The system has been verified by evaluating the distribution of the radiation dose-rate within the Monju primary heat transport system cells from the estimated saturated CP deposition and distribution which would be present following about 20 cycles of full power operation. (author)

  1. Development of dose rate estimation system for FBR maintenance

    International Nuclear Information System (INIS)

    Iizawa, Katsuyuki; Takeuchi, Jun; Yoshikawa, Satoru; Urushihara, Hiroshi

    2001-01-01

    During maintenance activities on the primary sodium cooling system by an FBR Personnel radiation exposure arises mainly from the presence of radioactive corrosion products (CP). A CP behavior analysis code, PSYCHE, and a radiation shielding calculation code, QAD-CG, have been developed and applied to investigate the possible reduction of radiation exposure of workers. In order to make these evaluation methods more accessible to plant engineers, the user interface of the codes has been improved and an integrated system, including visualization of the calculated gamma-ray radiation dose-rate map, has been developed. The system has been verified by evaluating the distribution of the radiation dose-rate within the Monju primary heat transport system cells from the estimated saturated CP deposition and distribution which would be present following about 20 cycles of full power operation. (author)

  2. On the Achievable Rate of Hardware-Impaired Transceiver Systems

    KAUST Repository

    Javed, Sidrah; Amin, Osama; Ikki, Salama S.; Alouini, Mohamed-Slim

    2018-01-01

    In this paper, we accurately model the transceiver hardware impairments (HWIs) of multiple-input multiple-output (MIMO) systems considering different HWI stages at transmitter and receiver. The proposed novel statistical model shows that transceiver HWIs transform the transmitted symmetric signal to asymmetric one. Moreover, it shows that the aggregate self-interference has asymmetric characteristics. Therefore, we propose improper Gaussian signaling (IGS) for transmission in order to improve the achievable rate performance. IGS is considered as a general signaling scheme which includes the proper Gaussian signaling (PGS) as a special case. Thus, IGS has additional design parameters which enable it to mitigate the HWI self-interference. As a case study, we analyze the achievable rate performance of single-input multiple-output systems with linear and selection combiner. Furthermore, we optimize the IGS statistical characteristics for interference alignment. This improves the achievable rate performance as compared to the PGS, which is validated through numerical results.

  3. On the Achievable Rate of Hardware-Impaired Transceiver Systems

    KAUST Repository

    Javed, Sidrah

    2018-01-15

    In this paper, we accurately model the transceiver hardware impairments (HWIs) of multiple-input multiple-output (MIMO) systems considering different HWI stages at transmitter and receiver. The proposed novel statistical model shows that transceiver HWIs transform the transmitted symmetric signal to asymmetric one. Moreover, it shows that the aggregate self-interference has asymmetric characteristics. Therefore, we propose improper Gaussian signaling (IGS) for transmission in order to improve the achievable rate performance. IGS is considered as a general signaling scheme which includes the proper Gaussian signaling (PGS) as a special case. Thus, IGS has additional design parameters which enable it to mitigate the HWI self-interference. As a case study, we analyze the achievable rate performance of single-input multiple-output systems with linear and selection combiner. Furthermore, we optimize the IGS statistical characteristics for interference alignment. This improves the achievable rate performance as compared to the PGS, which is validated through numerical results.

  4. The European debate on rate systems in the interwar period

    International Nuclear Information System (INIS)

    Madureira, Nuno Luis

    2010-01-01

    This article describes a particular branch that evolved in the diffusion of electrical rate systems in twentieth-century Europe and the debate that ensued between the competitive, promotional and cost based approaches. Three major questions are addressed: What factors and historical circumstances favoured the emergence of more or less efficient pricing schemes? Why did some enterprises opt for promotional rates while others defended the cost based alternative? What is the historical origin of marginal cost pricing? It is shown how the volatility of the costs that characterize hydro-electric production made this particular technology very sensitive to a cost approach towards pricing and to a seasonal and time-of-day perspective on rate systems. (author)

  5. Schedule for Rating Disabilities; the Endocrine System. Final rule.

    Science.gov (United States)

    2017-11-02

    This document amends the Department of Veterans Affairs (VA) Schedule for Rating Disabilities (VASRD) by revising the portion of the Schedule that addresses endocrine conditions and disorders of the endocrine system. The effect of this action is to ensure that the VASRD uses current medical terminology and to provide detailed and updated criteria for evaluation of endocrine disorders.

  6. 75 FR 13145 - SBA Lender Risk Rating System

    Science.gov (United States)

    2010-03-18

    ... SMALL BUSINESS ADMINISTRATION [Docket No. SBA-2010-0004] SBA Lender Risk Rating System AGENCY: Small Business Administration. ACTION: Notice; extension of comment period and correction. SUMMARY: On... of Credit Risk Management, U.S. Small Business Administration, 409 Third Street, SW., 8th Floor...

  7. The 1978 National Fire-Danger Rating System: technical documentation

    Science.gov (United States)

    Larry S. Bradshaw; John E. Deeming; Robert E. Burgan; Jack D. Cohen

    1984-01-01

    The National Fire-Danger Rating System (NFDRS), implemented in 1972, has been revised and reissued as the 1978 NFDRS. This report describes the full developmental history of the NFDRS, including purpose, technical foundation, and structure. Includes an extensive bibliography and appendixes.

  8. Rating PV Power and Energy: Cell, Module, and System Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Emery, Keith

    2016-06-02

    A summary of key points related to research-level measurements of current vs. voltage measurement theory including basic PV operation, equivalent circuit, and concept of spectral error; PV power performance including PV irradiance sensors, simulators and commercial and generic I-V systems; PV measurement artifacts, intercomparisons, and alternative rating methods.

  9. Quality Rating and Improvement Systems and Children's Cognitive Development

    Science.gov (United States)

    Jeon, Lieny; Buettner, Cynthia K.

    2015-01-01

    Background: Providing enriched learning environments is important to stimulating children's development in early childhood. Early child-care policymakers in many states in the US have adopted Quality Rating and Improvement Systems (QRIS) as a way to verify quality of child care and to support children's school readiness. Objective: The purpose of…

  10. Failure rate of piping in hydrogen sulphide systems

    International Nuclear Information System (INIS)

    Hare, M.G.

    1993-08-01

    The objective of this study is to provide information about piping failures in hydrogen sulphide service that could be used to establish failures rates for piping in 'sour service'. Information obtained from the open literature, various petrochemical industries and the Bruce Heavy Water Plant (BHWP) was used to quantify the failure analysis data. On the basis of this background information, conclusions from the study and recommendations for measures that could reduce the frequency of failures for piping systems at heavy water plants are presented. In general, BHWP staff should continue carrying out their present integrity and leak detection programmes. The failure rate used in the safety studies for the BHWP appears to be based on the rupture statistics for pipelines carrying sweet natural gas. The failure rate should be based on the rupture rate for sour gas lines, adjusted for the unique conditions at Bruce

  11. Radiation dosemeters and ambient dose rate measuring systems

    International Nuclear Information System (INIS)

    Maushart, R.

    1985-01-01

    The manufacturers have got the feeling that the PTB only reluctantly accepts complex dosimetric systems or systems with modern digital and microprocessor technology. Especially the fact that the PTB demands a restriction to a defined system configuration which must not be changed after design approval is felt to be a severe handicap. The rigid frame of design qualification forces manufacturers to adopt a two-tier development line, at least for ambient dose rate measuring systems, and frequently it is not necessarily the 'nature' system, i.e. equipment with modern technology, that is sent in to the PTB for testing. The way of solving the problem could be that PTB more readily accepts less familiar technologies, for instance by more frequently approving equipment at least preliminarily or for a restricted period of time, in order to collect experience. Another way could be to grant licence for system components, especially detectors. (orig./HP) [de

  12. ADOÇÃO DA CERTIFICAÇÃO LEED EM MEIOS DE HOSPEDAGEM: ESVERDEANDO A HOTELARIA?

    Directory of Open Access Journals (Sweden)

    Mirna de Lima Medeiros

    2012-03-01

    Full Text Available The research intended to analyze the adoption process of the green certification “Leadership in Energy and Environmental Design” (LEED from the hotel sector establishments that has already adopted it. For its concretization it was proceeded a bibliographical research, secondary fact-gathering in journals, institutional sites and documentaries, and primary fact-gathering by means of semi structured interviews carried out with responsible people of the certified hotels and of the responsible entity of the certification in Brazil (Green Building Council Brazil. There were 21 interviewee, being 02 of the GBC Brazil and 19 of means of lodging (31% of the certified. For data analysis, it was utilized content analysis technique with the aid of ATLAS.ti software. The results permitted to identify the chronology of the processes of certification and the profile of the hotel categories that adopt the LEED program. Beyond that, the interviews enabled the discussion of the initial motivations for seeking the certification, as well the advantages and the obstacles perceived regarding its adoption.

  13. Comparing replacement rates under private and federal retirement systems.

    Science.gov (United States)

    Martin, Patricia P

    One measure of the adequacy of retirement income is replacement rate - the percentage of pre-retirement salary that is available to a worker in retirement. This article compares salary replacement rates for private-sector employees of medium and large private establishments with those for federal employees under the Civil Service Retirement System and the Federal Employees Retirement System. Because there is no standard benefit formula to represent the variety of formulas available in the private sector, a composite defined benefit formula was developed using the characteristics of plans summarized in the Bureau of Labor Statistics Medium and Large Employer Plan Survey. The resulting "typical" private-sector defined benefit plan, with an accompanying defined contribution plan, was then compared with the two federal systems. The Civil Service Retirement System (CSRS) is a stand-alone defined benefit plan whose participants are not covered by Social Security. Until passage of the 1983 Amendments to Social Security Act, it was the only retirement plan for most federal civilian employees. Provisions of the 1983 Amendments were designed to restore long-term financial stability to the Social Security trust funds. One provision created the Federal Employees Retirement System (FERS), which covers federal employees hired after 1983. It was one of the provisions designed to restore long-term financial stability to the Social Security trust funds. FERS employees contribute to and are covered by Social Security. FERS, which is a defined benefit plan, also includes a basic benefit and a 401(k)-type plan known as the Thrift Savings Plan (TSP). To compare how retirees would fare under the three different retirement systems, benefits of employees retiring at age 65 with 35 years of service were calculated using hypothetical workers with steady earnings. Workers were classified according to a percentage of the average wage in the economy: low earners (45 percent), average earners

  14. High rate tests of the LHCb RICH Upgrade system

    CERN Multimedia

    Blago, Michele Piero

    2016-01-01

    One of the biggest challenges for the upgrade of the LHCb RICH detectors from 2020 is to readout the photon detectors at the full 40 MHz rate of the LHC proton-proton collisions. A test facility has been setup at CERN with the purpose to investigate the behaviour of the Multi Anode PMTs, which have been proposed for the upgrade, and their readout electronics at high trigger rates. The MaPMTs are illuminated with a monochromatic laser that can be triggered independently of the readout electronics. A first series of tests, including threshold scans, is performed at low trigger rates (20 kHz) for both the readout and the laser with the purpose to characterise the behaviour of the system under test. Then the trigger rate is increased in two separate steps. First the MaPMTs are exposed to high illumination by triggering the pulsed laser at a high (20 MHz) repetition rate while the DAQ is readout at the same low rate as before. In this way the performance of the MaPMTs and the attached electronics can be evaluated ...

  15. Variation in Payment Rates under Medicare's Inpatient Prospective Payment System.

    Science.gov (United States)

    Krinsky, Sam; Ryan, Andrew M; Mijanovich, Tod; Blustein, Jan

    2017-04-01

    To measure variation in payment rates under Medicare's Inpatient Prospective Payment System (IPPS) and identify the main payment adjustments that drive variation. Medicare cost reports for all Medicare-certified hospitals, 1987-2013, and Dartmouth Atlas geographic files. We measure the Medicare payment rate as a hospital's total acute inpatient Medicare Part A payment, divided by the standard IPPS payment for its geographic area. We assess variation using several measures, both within local markets and nationally. We perform a factor decomposition to identify the share of variation attributable to specific adjustments. We also describe the characteristics of hospitals receiving different payment rates and evaluate changes in the magnitude of the main adjustments over time. Data downloaded from the Centers for Medicare and Medicaid Services, the National Bureau of Economic Research, and the Dartmouth Atlas. In 2013, Medicare paid for acute inpatient discharges at a rate 31 percent above the IPPS base. For the top 10 percent of discharges, the mean rate was double the IPPS base. Variations were driven by adjustments for medical education and care to low-income populations. The magnitude of variation has increased over time. Adjustments are a large and growing share of Medicare hospital payments, and they create significant variation in payment rates. © Health Research and Educational Trust.

  16. Performance of slow rate systems for treatment of domestic wastewater.

    Science.gov (United States)

    Tzanakakis, V E; Paranychianakis, N V; Angelakis, A N

    2007-01-01

    The performance of slow rate (SR) systems in terms of treatment efficiency, environmental and health risks, and land sustainability was investigated over a three-year period in a rural community close to Iraklio, Greece. Four plant species (Acacia cyanophylla, Eucalyptus camandulensis, Populus nigra and Arundo donax) were used in order to investigate the role of vegetation in the treatment of wastewater and in biomass production. Wastewater effluent was pre-treated in a septic tank before its application to land. Applied hydraulic loading rates were based on crop water requirements which were determined separately for each plant species. The evaluation of treatment performance was accomplished by measuring COD, TKN, NH3-N, NO3-N, total and reactive P, TC and FC in soil solution samples taken at different depths (15, 30 and 60 cm). SR systems showed great potential for COD, TKN and NH4-N removal which reached 89, 90 and 94%, respectively at a depth of 15 cm. An outstanding removal was also observed for TC and FC which reached 99.99%. The concentration of both P and NO3-N in soil solution increased with the passage of time, but it was lower in winter. Despite the differences in the application rates among the SR systems planted with different plant species, the treatment efficiency was not affected. Moreover, increasing the soil depth from 15 to 60 cm had no effect on the treatment efficiency of the SR systems.

  17. Rated power factor and excitation system of large turbine generator

    International Nuclear Information System (INIS)

    Tokumitsu, Iwao; Watanabe, Takashi; Banjou, Minoru.

    1979-01-01

    As for the rated power factor of turbine generators for thermal power stations, 90% has been adopted since around 1960. On the other hand, power transmission system has entered 500 kV age, and 1,000 kV transmission is expected in the near future. As for the supply of reactive power from thermal and nuclear turbine generators, the necessity of supplying leading reactive power has rather increased. Now, the operating power factor of thermal and nuclear generators becomes 96 to 100% actually. As for the excess stability of turbine generators owing to the strengthening of transmission system and the adoption of super-high voltage, the demand of strict conditions can be dealt with by the adoption of super-fast response excitation system of thyristor shunt winding self exciting type. The adoption of the turbine generators with 90 to 95% power factor and the adoption of the thyristor shunt winding self exciting system were examined and evaluated. The rated power factor of generators, excitation system and economy of adopting these systems are explained. When the power factor of generators is increased from 0.9 to 0.95, about 6% of saving can be obtained in the installation cost. When the thyristor shunt winding self excitation is adopted, it is about 10% more economical than AC excitation. (Kako, I.)

  18. High rate 4π β-γ coincidence counting system

    International Nuclear Information System (INIS)

    Johnson, L.O.; Gehrke, R.J.

    1978-01-01

    A high count rate 4π β-γ coincidence counting system for the determination of absolute disintegration rates of short half-life radionuclides is described. With this system the dead time per pulse is minimized by not stretching any pulses beyond the width necessary to satisfy overlap coincidence requirements. The equations used to correct for the β, γ, and coincidence channel dead times and for accidental coincidences are presented but not rigorously developed. Experimental results are presented for a decaying source of 56 Mn initially at 2 x 10 6 d/s and a set of 60 Co sources of accurately known source strengths varying from 10 3 to 2 x 10 6 d/s. A check of the accidental coincidence equation for the case of two independent sources with varying source strengths is presented

  19. Comodulation masking release in bit-rate reduction systems

    DEFF Research Database (Denmark)

    Vestergaard, Martin David; Rasmussen, Karsten Bo; Poulsen, Torben

    1999-01-01

    It has been suggested that the level dependence of the upper masking slope be utilized in perceptual models in bit-rate reduction systems. However, comodulation masking release (CMR) phenomena lead to a reduction of the masking effect when a masker and a probe signal are amplitude modulated...... with the same frequency. In bit-rate reduction systems the masker would be the audio signal and the probe signal would represent the quantization noise. Masking curves have been determined for sinusoids and 1-Bark-wide noise maskers in order to investigate the risk of CMR, when quantizing depths are fixed...... in accordance with psycho-acoustical principles. Masker frequencies of 500 Hz, 1 kHz, and 2 kHz have been investigated, and the masking of pure tone probes has been determined in the first four 1/3 octaves above the masker. Modulation frequencies between 6 and 20 Hz were used with a modulation depth of 0...

  20. Secondary standard dosimetry system with automatic dose/rate calculation

    International Nuclear Information System (INIS)

    Duftschmid, K.E.; Bernhart, J.; Stehno, G.; Klosch, W.

    1980-01-01

    A versatile and automated secondary standard instrument has been designed for quick and accurate dose/rate measurement in a wide range of radiation intensity and quality (between 1 μR and 100 kR; 0.2 nC/kg - 20C/kg) for protection and therapy level dosimetry. The system is based on a series of secondary standard ionization chambers connected to a precision digital current integrator with microprocessor circuitry for data evaluation and control. Input of measurement parameters and calibration factors stored in an exchangeable memory chip provide computation of dose/rate values in the desired units. The ionization chambers provide excellent long-term stability and energy response and can be used with internal check sources to test validity of calibration. The system is a useful tool particularly for daily measurements in a secondary standard dosimetry laboratory or radiation therapy center. (H.K.)

  1. Estimating marginal CO2 emissions rates for national electricity systems

    International Nuclear Information System (INIS)

    Hawkes, A.D.

    2010-01-01

    The carbon dioxide (CO 2 ) emissions reduction afforded by a demand-side intervention in the electricity system is typically assessed by means of an assumed grid emissions rate, which measures the CO 2 intensity of electricity not used as a result of the intervention. This emissions rate is called the 'marginal emissions factor' (MEF). Accurate estimation of MEFs is crucial for performance assessment because their application leads to decisions regarding the relative merits of CO 2 reduction strategies. This article contributes to formulating the principles by which MEFs are estimated, highlighting the strengths and weaknesses in existing approaches, and presenting an alternative based on the observed behaviour of power stations. The case of Great Britain is considered, demonstrating an MEF of 0.69 kgCO 2 /kW h for 2002-2009, with error bars at +/-10%. This value could reduce to 0.6 kgCO 2 /kW h over the next decade under planned changes to the underlying generation mix, and could further reduce to approximately 0.51 kgCO 2 /kW h before 2025 if all power stations commissioned pre-1970 are replaced by their modern counterparts. Given that these rates are higher than commonly applied system-average or assumed 'long term marginal' emissions rates, it is concluded that maintenance of an improved understanding of MEFs is valuable to better inform policy decisions.

  2. Positron imaging system with improved count rate and tomographic capability

    International Nuclear Information System (INIS)

    Muehllehner, G.; Buchin, M.P.

    1980-01-01

    Improvements to a positron camera imaging system are described. A pair of Angear-type scintillation cameras serve as the detectors, each camera being positioned on opposite sides of the organ of interest. Pulse shaping circuits reduce the pulse duration below 900 nanoseconds and the integration time below 500 noneseconds, improving the count rate capability and the counting statistics of the system and thus the image quality and processing speed. The invention also provides means for rotating the opposed camera heads about an axis which passes through the organ of interest. The cameras do not use collimators, and are capable of accepting radiation travelling in planes not perpendicular to the scintillation crystals. (LL)

  3. Drift chamber system for use in a high rate environment

    International Nuclear Information System (INIS)

    Etkin, A.

    1978-01-01

    A system of short drift distance (0.125'') drift chambers is described. This system is being built for use in the Brookhaven National Laboratory Multiparticle Spectrometer. These chambers will be able to handle beam rates of several million/pulse and give a spatial resolution of the order of 150 μm. Cathode readout will provide unique 3-dimensional points for each crack. The readout will utilize three custom built integrated circuits, a four channel amplifier-shaper, a four channel discriminator and a four channel shift register delay and time digitizer. A summary of test results on a prototype is also given

  4. Asymmetric Effects on Escape Rates of Bistable System

    International Nuclear Information System (INIS)

    Wang Canjun; Mei Dongcheng; Dai Zucheng

    2011-01-01

    The asymmetric effects on the escape rates from the stable states x ± in the bistable system are analyzed. The results indicate that the multiplicative noise and the additive noise always enhance the particle escape from stable states x ± of bistable. However, the asymmetric parameter r enhances the particle escape from stable state x + , and holds back the particle escape from stable state x - . (general)

  5. Fabrication and evaluation of variable rate fertilizer system

    Directory of Open Access Journals (Sweden)

    A Damirchi

    2015-09-01

    Full Text Available Introduction: In conventional farming, the soil and crop are considered uniform in different locations of the farm and the fertilizers are applied according to the average of soil needs with an additional percentage for safety (Loghavi, 2003. Non-essential chemical fertilizers in the field have harmful effects and social, economic and environmental concerns will increase. Many fertilizers go into the surface waters and ground waters and cause poisoning and environmental pollution without being absorbed by the plants. In variable rate technology, the soil fertilizer needs a map of all parts of the farm which is prepared with the GIS system. This map is uploaded on the computer before variable rate fertilizer machine starts. The computer continually controls the fertilizing rate for each part of the farm using a fertilizing map and global positioning system. The purpose of this study is to construct and evaluate a map-based variable rate fertilizer system that can be installed on a common fertilizer in Iran to be used as a variable rate system. Materials and methods: In common variable rate fertilizers, the rotational speed change of the distributor shaft is used to apply fertilizers. In this way, a DC motor is assembled on the main shaft of all distributors, which reduces the fertilizing accuracy. The reason for this is that there is no separation for units along the width of the fertilizer. Therefore, we used one DC motor for each distributor and another motor to rotate the agitator in the tank. System Set up: To design and select a suitable engine, the required torque for the rotation distributor shaft was measured by a torque meter and the amount of 2.1 Nm was acquired for that. With regard to the maximum rate of nitrogen fertilizer for land and tractor speed at the time of fertilizing, the order of 350 kg per hectare and 8 km per hour, the maximum distributor shaft speed and power required to rotate distributor shaft were calculated to be 55

  6. Effects of Contract Delivery Method on the LEED(trademark) Score of U.S. Navy Military Construction Projects (Fiscal Years 2004-2006) (CD-ROM)

    National Research Council Canada - National Science Library

    Carpenter, Deanna S

    2005-01-01

    ...: 1 CD-ROM; 4 3/4 in.; 484 KB. ABSTRACT: This research study focused on determining the effects that the two major contract delivery methods had on the LEED score of projects over the design and construction time horizon...

  7. Surface structure and electronic states of epitaxial β-FeSi.sub.2./sub.(100)/Si(001) thin films: Combined quantitative LEED, ab initio DFT, and STM study

    Czech Academy of Sciences Publication Activity Database

    Romanyuk, Olexandr; Hattori, K.; Someta, M.; Daimon, H.

    2014-01-01

    Roč. 90, č. 15 (2014), "155305-1"-"155305-9" ISSN 1098-0121 Grant - others:AVČR(CZ) M100101201; Murata Science Foundation(JP) Project n. 00295 Institutional support: RVO:68378271 Keywords : iron silicide * LEED I-V * DFT * STM * surface reconstruction * surface states Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 3.736, year: 2014

  8. Comparability of the Social Skills Improvement System to the Social Skills Rating System: A Norwegian Study

    Science.gov (United States)

    Gamst-Klaussen, Thor; Rasmussen, Lene-Mari P.; Svartdal, Frode; Strømgren, Børge

    2016-01-01

    The Social Skills Improvement System-Rating Scales (SSIS-RS) is a multi-informant instrument assessing social skills and problem behavior in children and adolescents. It is a revised version of the Social Skills Rating System (SSRS). A Norwegian translation of the SSRS has been validated, but this has not yet been done for the Norwegian…

  9. Producing 'internal suspect bodies': divisive effects of UK counter-terrorism measures on Muslim communities in Leeds and Bradford.

    Science.gov (United States)

    Abbas, Madeline-Sophie

    2018-04-06

    Research on UK government counter-terrorism measures has claimed that Muslims are treated as a 'suspect community'. However, there is limited research exploring the divisive effects that membership of a 'suspect community' has on relations within Muslim communities. Drawing from interviews with British Muslims living in Leeds or Bradford, I address this gap by explicating how co-option of Muslim community members to counter extremism fractures relations within Muslim communities. I reveal how community members internalize fears of state targeting which precipitates internal disciplinary measures. I contribute the category of 'internal suspect body' which is materialized through two intersecting conditions within preventative counter-terrorism: the suspected extremist for Muslims to look out for and suspected informer who might report fellow Muslims. I argue that the suspect community operates through a network of relations by which terrors of counter-terrorism are reproduced within Muslim communities with divisive effects. © London School of Economics and Political Science 2018.

  10. Challenging Racist Violence and Racist Hostility in 'Post-Racial' Times: Research and Action in Leeds, UK, 2006–2012

    Directory of Open Access Journals (Sweden)

    Ian Law

    2013-04-01

    Full Text Available Despite increasing understanding of, information about and official commitment to challenge these patterns, racist hostility and violence continue to have an enduring presence in urban and rural life in the UK. This indicates the paradoxical nature of this racial crisis and challenges for antiracism as a political project. This paper charts how these issues play out at the local level through an examination of a five year process from problem identification through to research, response, action and aftermath from 2006 to 2012 in the city of Leeds, UK, with a focus on two predominantly white working class social housing estates in the city. We explore how embedded tensions and antagonisms can begin to be challenged, while examining how the contemporary climate of austerity and cuts in services, together with prevailing post-racial thinking, make the likelihood of such concerted action in the UK increasingly remote.

  11. Energy Provisions of the ICC-700, LEED for Homes, and ENERGY STAR Mapped to the 2009 IECC

    Energy Technology Data Exchange (ETDEWEB)

    Britt, Michelle L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sullivan, Robin S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kora, Angela R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Makela, Eric J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Makela, Erin [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2011-05-01

    This document provides the results of a comparison of building energy efficient elements of the ICC-700 National Green Building Standard, LEED for Homes, and ENERGY STAR versions 2, 2.5, and 3.0 to the 2009 International Energy Conservation Code (2009 IECC). This comparison will provide a tool for states and local municipalities as they consider adoption of these programs. The comparison is presented in a series of appendices. The first appendix provides a summary chart that visually represents the comprehensive comparison of the programs to the 2009 IECC topic areas. Next there are a series of individual tables (one appendix for each program) that include the specific program mapping to the 2009 IECC elements with comments that briefly discuss how well the elements mapped. Finally, a comprehensive table is included that shows all five of the programs mapped to the 2009 IECC elements to allow a detailed comparison.

  12. Life Cycle Assessment and Optimization-Based Decision Analysis of Construction Waste Recycling for a LEED-Certified University Building

    Directory of Open Access Journals (Sweden)

    Murat Kucukvar

    2016-01-01

    Full Text Available The current waste management literature lacks a comprehensive LCA of the recycling of construction materials that considers both process and supply chain-related impacts as a whole. Furthermore, an optimization-based decision support framework has not been also addressed in any work, which provides a quantifiable understanding about the potential savings and implications associated with recycling of construction materials from a life cycle perspective. The aim of this research is to present a multi-criteria optimization model, which is developed to propose economically-sound and environmentally-benign construction waste management strategies for a LEED-certified university building. First, an economic input-output-based hybrid life cycle assessment model is built to quantify the total environmental impacts of various waste management options: recycling, conventional landfilling and incineration. After quantifying the net environmental pressures associated with these waste treatment alternatives, a compromise programming model is utilized to determine the optimal recycling strategy considering environmental and economic impacts, simultaneously. The analysis results show that recycling of ferrous and non-ferrous metals significantly contributed to reductions in the total carbon footprint of waste management. On the other hand, recycling of asphalt and concrete increased the overall carbon footprint due to high fuel consumption and emissions during the crushing process. Based on the multi-criteria optimization results, 100% recycling of ferrous and non-ferrous metals, cardboard, plastic and glass is suggested to maximize the environmental and economic savings, simultaneously. We believe that the results of this research will facilitate better decision making in treating construction and debris waste for LEED-certified green buildings by combining the results of environmental LCA with multi-objective optimization modeling.

  13. Validity and reliability of the Spanish-language version of the self-administered Leeds Assessment of Neuropathic Symptoms and Signs (S-LANSS) pain scale.

    Science.gov (United States)

    López-de-Uralde-Villanueva, I; Gil-Martínez, A; Candelas-Fernández, P; de Andrés-Ares, J; Beltrán-Alacreu, H; La Touche, R

    2016-12-08

    The self-administered Leeds Assessment of Neuropathic Symptoms and Signs (S-LANSS) scale is a tool designed to identify patients with pain with neuropathic features. To assess the validity and reliability of the Spanish-language version of the S-LANSS scale. Our study included a total of 182 patients with chronic pain to assess the convergent and discriminant validity of the S-LANSS; the sample was increased to 321 patients to evaluate construct validity and reliability. The validated Spanish-language version of the ID-Pain questionnaire was used as the criterion variable. All participants completed the ID-Pain, the S-LANSS, and the Numerical Rating Scale for pain. Discriminant validity was evaluated by analysing sensitivity, specificity, and the area under the receiver operating characteristic curve (AUC). Construct validity was assessed with factor analysis and by comparing the odds ratio of each S-LANSS item to the total score. Convergent validity and reliability were evaluated with Pearson's r and Cronbach's alpha, respectively. The optimal cut-off point for S-LANSS was ≥12 points (AUC=.89; sensitivity=88.7; specificity=76.6). Factor analysis yielded one factor; furthermore, all items contributed significantly to the positive total score on the S-LANSS (P<.05). The S-LANSS showed a significant correlation with ID-Pain (r=.734, α=.71). The Spanish-language version of the S-LANSS is valid and reliable for identifying patients with chronic pain with neuropathic features. Copyright © 2016 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Pilot Study of a Plug Load Management System: Preparing for Sustainability Base

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA Ames Research Center’s Sustainability Base is a new 50,000 sq. ft. high-performance office building targeting a LEED Platinum rating. Plug loads are expected to...

  15. Safety handling manual for high dose rate remote afterloading system

    International Nuclear Information System (INIS)

    1999-01-01

    This manual is mainly for safety handling of 192 Ir-RALS (remote afterloading system) of high dose rate and followings were presented: Procedure and document format for the RALS therapy and for handling of its radiation source with the purpose of prevention of human errors and unexpected accidents, Procedure for preventing errors occurring in the treatment schedule and operation, and Procedure and format necessary for newly introducing the system into a facility. Consistency was intended in the description with the quality assurance guideline for therapy with small sealed radiation sources made by JASTRO (Japan Society for Therapeutic Radiology and Oncology). Use of the old type 60 Co-RALS was pointed out to be a serious problem remained and its safety handling procedure was also presented. (K.H.)

  16. Sum-Rate Maximization of Coordinated Direct and Relay Systems

    DEFF Research Database (Denmark)

    Sun, Fan; Popovski, Petar; Thai, Chan

    2012-01-01

    Joint processing of multiple communication flows in wireless systems has given rise to a number of novel transmission techniques, notably the two-way relaying based on wireless network coding. Recently, a related set of techniques has emerged, termed coordinated direct and relay (CDR) transmissions......, where the constellation of traffic flows is more general than the two-way. Regardless of the actual traffic flows, in a CDR scheme the relay has a central role in managing the interference and boosting the overall system performance. In this paper we investigate the novel transmission modes, based...... on amplify-and-forward, that arise when the relay is equipped with multiple antennas and can use beamforming. We focus on one representative traffic type, with one uplink and one downlink users and consider the achievable sum-rate maximization relay beamforming. The beamforming criterion leads to a non...

  17. 75 FR 9257 - SBA Lender Risk Rating System

    Science.gov (United States)

    2010-03-01

    ... Liquidation Rate; 3. Gross Delinquency Rate; 4. Gross Past-Due Rate; 5. Six (6) Month Net Flow Indicator; 6.... The statistical analysis performed showed that incorporating the Portfolio Size/Age component improved...) Month Delinquency Rate; 3. Gross Delinquency Rate; 4. Gross Past-Due Rate; 5. Average Small Business...

  18. A review on leakage rate tests for containment isolation systems

    International Nuclear Information System (INIS)

    Kim, In Goo; Kim, Hho Jung

    1992-01-01

    Wide experiences in operating containment isolation systems have been accumulated in Korea since 1978. Hence, it becomes necessary to review the operating data in order to confirm the integrity of containments with about 50 reactor-years of experience and to establish the future direction to the containment test program. The objectives of present work are to collect, consolidate and assess the leakage rate data, and then to find out dominant leakage paths and factors affecting integrated leakage rate test. General trends of overall leakage show that more careful surveillance during pre-operational test can reduce the containment leakage. Dominant leakage paths are found to be through air locks and large-sized valves, such as butterfly valves of purge lines, so that weighted surveillance and inspection on these dominant leakage paths can considerably reduce the containment leakage. The atmosphere stabilization are found to be the most important to obtain the reliable result. In order to get well stabilized atmosphere, temperature and flow rate of compressed air should be kept constant and it is preferable not to operate fan cooler during pressurizing the containment for test

  19. A rating system for post pulse data validation

    International Nuclear Information System (INIS)

    Buceti, G.; Centioli, Cristina; Iannone, F.; Panella, M.; Rizzo, A.; Vitale, V.

    2003-01-01

    The aim of an automatic data validation system in a fusion experiment is to account--after every shot--for any occurrence of faulty sensors and unreliable measurements, thus preventing the proliferation of poor pulse data. In the past years a prototype has been successfully developed at Frascati Tokamak Upgrade (FTU) on a small set of density measurements. The results have shown that the model can be further extended to plant and diagnostic data, and that the same system can be used to assign to raw data a quality factor, to be stored in the archive and to be used in the post-shot elaboration phase as a selection criterion. In this way, a data validation system can also provide data analysts with an useful tool to be used as a key--together with other significant parameters, like plasma current, or magnetic field--to search the archive for quality data. This paper will describe how, using soft computing techniques, both these functions have been implemented on FTU, providing the users with a simple interface for fault detection developed in an open source environment (PHP-MySQL), to be finalised into the realisation of an overall rating system for FTU data

  20. A rating system for post pulse data validation

    Energy Technology Data Exchange (ETDEWEB)

    Buceti, G.; Centioli, Cristina E-mail: centioli@frascati.enea.it; Iannone, F.; Panella, M.; Rizzo, A.; Vitale, V

    2003-09-01

    The aim of an automatic data validation system in a fusion experiment is to account--after every shot--for any occurrence of faulty sensors and unreliable measurements, thus preventing the proliferation of poor pulse data. In the past years a prototype has been successfully developed at Frascati Tokamak Upgrade (FTU) on a small set of density measurements. The results have shown that the model can be further extended to plant and diagnostic data, and that the same system can be used to assign to raw data a quality factor, to be stored in the archive and to be used in the post-shot elaboration phase as a selection criterion. In this way, a data validation system can also provide data analysts with an useful tool to be used as a key--together with other significant parameters, like plasma current, or magnetic field--to search the archive for quality data. This paper will describe how, using soft computing techniques, both these functions have been implemented on FTU, providing the users with a simple interface for fault detection developed in an open source environment (PHP-MySQL), to be finalised into the realisation of an overall rating system for FTU data.

  1. A high rate clarifier for load levelling in sewerage systems.

    Science.gov (United States)

    Jago, R A; Davey, A; Li, H

    2003-01-01

    The combining of chemically assisted clarification with a proprietary physical separation technology has led to a high rate process for clarifying flocculated sewage and other waste streams. This hybrid physico-chemical system, known as the CDS Fine Solids Separation (FSS) System, was developed over a two year period within a sewage treatment plant environment. This paper summarises the results of a recent field trial of the system with a Victorian water authority which experiences heavy loading of sewers in a coastal town during holiday periods. The trial sought to evaluate the FSS as a tool for smoothing the load on the 11 km long sewer to the sewage treatment plant (STP). The FSS system could possibly enable the costly augmentation of the sewer to be deferred, particularly as the capacity of the existing sewer pipe is satisfactory for most of the year. Water quality parameters were determined for a range of flowrates and operational conditions over a two month period. Large reductions were achieved in TSS, TP, FC, turbidity and BOD5, with only minimal reductions in NH3 and TON. These results showed that the FSS could meet the authority's objectives for load levelling and would provide a 20-25% increase in effective sewer capacity. The data are also discussed in terms of possible use of the effluent from the FSS for water reuse applications.

  2. The mechanics of granitoid systems and maximum entropy production rates.

    Science.gov (United States)

    Hobbs, Bruce E; Ord, Alison

    2010-01-13

    A model for the formation of granitoid systems is developed involving melt production spatially below a rising isotherm that defines melt initiation. Production of the melt volumes necessary to form granitoid complexes within 10(4)-10(7) years demands control of the isotherm velocity by melt advection. This velocity is one control on the melt flux generated spatially just above the melt isotherm, which is the control valve for the behaviour of the complete granitoid system. Melt transport occurs in conduits initiated as sheets or tubes comprising melt inclusions arising from Gurson-Tvergaard constitutive behaviour. Such conduits appear as leucosomes parallel to lineations and foliations, and ductile and brittle dykes. The melt flux generated at the melt isotherm controls the position of the melt solidus isotherm and hence the physical height of the Transport/Emplacement Zone. A conduit width-selection process, driven by changes in melt viscosity and constitutive behaviour, operates within the Transport Zone to progressively increase the width of apertures upwards. Melt can also be driven horizontally by gradients in topography; these horizontal fluxes can be similar in magnitude to vertical fluxes. Fluxes induced by deformation can compete with both buoyancy and topographic-driven flow over all length scales and results locally in transient 'ponds' of melt. Pluton emplacement is controlled by the transition in constitutive behaviour of the melt/magma from elastic-viscous at high temperatures to elastic-plastic-viscous approaching the melt solidus enabling finite thickness plutons to develop. The system involves coupled feedback processes that grow at the expense of heat supplied to the system and compete with melt advection. The result is that limits are placed on the size and time scale of the system. Optimal characteristics of the system coincide with a state of maximum entropy production rate. This journal is © 2010 The Royal Society

  3. An Auto Telematics System For Insurance Premium Rating amp Pricing.

    Directory of Open Access Journals (Sweden)

    Irode Philip Luvuga

    2017-12-01

    Full Text Available Insurance telematics is a new technology that has been poised to transform and change the way we buy and underwrite insurance by 2030. Insurance Premium Rate is a major variable that determines if a client will buy or take up a policy cover or not. With the current stiff competition being felt in the Industry the local insurance industry continues to suffer big losses due to unhealthy business practice of competitor undercutting among the insurers to attract more clients but exposing the underwriting companies to potential high risks. This in most cases means that the product is totally underpriced to the extent that it would be uneconomical and unsustainable in the long run for the insurance firms. This research outlines a technology defined model that should be used to determine the ideal premium rate payable in the Motor Insurance industry taking into account all the variables and the risk exposure of the policy holder. The system model is able to determine the insurable risk based on the drivers attributes and profile location of the vehicle in relation to risk geo-locations map monitoring the driving parameters of the vehicle by the driver and the driving style. This enable the insurance company determines costs associated with the risk cover based on factual facts which are scientifically determined by the real risks.

  4. The evaluation system of city's smart growth success rates

    Science.gov (United States)

    Huang, Yifan

    2018-04-01

    "Smart growth" is to pursue the best integrated perform+-ance of the Economically prosperous, socially Equitable, and Environmentally Sustainable(3E). Firstly, we establish the smart growth evaluation system(SGI) and the sustainable development evaluation system(SDI). Based on the ten principles and the definition of three E's of sustainability. B y using the Z-score method and the principal component analysis method, we evaluate and quantify indexes synthetically. Then we define the success of smart growth as the ratio of the SDI to the SGI composite score growth rate (SSG). After that we select two cities — Canberra and Durres as the objects of our model in view of the model. Based on the development plans and key data of these two cities, we can figure out the success of smart growth. And according to our model, we adjust some of the growth indicators for both cities. Then observe the results before and after adjustment, and finally verify the accuracy of the model.

  5. A Distributed Flow Rate Control Algorithm for Networked Agent System with Multiple Coding Rates to Optimize Multimedia Data Transmission

    Directory of Open Access Journals (Sweden)

    Shuai Zeng

    2013-01-01

    Full Text Available With the development of wireless technologies, mobile communication applies more and more extensively in the various walks of life. The social network of both fixed and mobile users can be seen as networked agent system. At present, kinds of devices and access network technology are widely used. Different users in this networked agent system may need different coding rates multimedia data due to their heterogeneous demand. This paper proposes a distributed flow rate control algorithm to optimize multimedia data transmission of the networked agent system with the coexisting various coding rates. In this proposed algorithm, transmission path and upload bandwidth of different coding rate data between source node, fixed and mobile nodes are appropriately arranged and controlled. On the one hand, this algorithm can provide user nodes with differentiated coding rate data and corresponding flow rate. On the other hand, it makes the different coding rate data and user nodes networked, which realizes the sharing of upload bandwidth of user nodes which require different coding rate data. The study conducts mathematical modeling on the proposed algorithm and compares the system that adopts the proposed algorithm with the existing system based on the simulation experiment and mathematical analysis. The results show that the system that adopts the proposed algorithm achieves higher upload bandwidth utilization of user nodes and lower upload bandwidth consumption of source node.

  6. Managing Clutter in a High Pulse Rate Echolocation System

    Directory of Open Access Journals (Sweden)

    Jacob Isbell

    2018-03-01

    Full Text Available The use of echolocation for navigating in dense, cluttered environments is a challenge due to the need for rapid sampling of nearby objects in the face of delayed echoes from distant objects. In the wild, echolocating bats frequently encounter this situation when leaving the roost or while hunting. If long-delay echoes from a distant object are received after the next pulse is sent out, these “aliased” echoes appear as close-range phantom objects. Little is known about how bats cope with these situations. In this work, we demonstrate a novel strategy to manage aliasing in cases where a single target is actively being tracked at close range. This paper presents three reactive strategies for a high pulse-rate sonar system to combat aliased echoes: (1 changing the interpulse interval to move the aliased echoes away in time from the tracked target, (2 changing positions to create a geometry without aliasing, and (3 a phase-based, transmission beam-shaping strategy to illuminate the target and not the aliasing object.

  7. Smart integrated containment leakage rate test system using wireless communication

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Hwan; Lee, Sang Yong; Kim, Jung Sun; Kim, Gun Soo; Kim, Jong Myeong; Ahn, Jong Han [Research and Development Center, Ulsan (Korea, Republic of)

    2012-10-15

    Integrated Leakage Rate Test (ILRT) is the important test the confidentiality and integrity of the containment building, which is the last barrier when Design basis accidents (DBA) of Nuclear Power plant occur. Since the result of this test is the basis to guarantee the safety of nuclear power plants, the test process, test procedure, and the test equipment are required to have high reliability. The test devices previously used have been products of VOLUMERTRICS and GRAFTEL of USA. These devices have been inconvenient to calibrate and use. Thus improved devices needed to be developed to remove the inconveniences, to verify the safety of Korean nuclear power plants with Korea's own technology, and to secure core technology. A new leak test system was developed by domestic technology for that purpose and needed to be verified. In this paper, technical details of the newly developed easy to use and highly reliable measuring test device, which is in operation at the nuclear power plant sites, will be introduced. State of art technology was applied to the device to address the shortcomings of previous US made devices and the difficulties to use on site.

  8. Mixing rates of particle systems with energy exchange

    International Nuclear Information System (INIS)

    Grigo, A; Khanin, K; Szász, D

    2012-01-01

    A fundamental problem of non-equilibrium statistical mechanics is the derivation of macroscopic transport equations in the hydrodynamic limit. The rigorous study of such limits requires detailed information about rates of convergence to equilibrium for finite sized systems. In this paper, we consider the finite lattice {1, 2, …, N}, with an energy x i ∈ (0, ∞) associated with each site. The energies evolve according to a Markov jump process with nearest neighbour interaction such that the total energy is preserved. We prove that for an entire class of such models the spectral gap of the generator of the Markov process scales as O(N -2 ). Furthermore, we provide a complete classification of reversible stationary distributions of product type. We demonstrate that our results apply to models similar to the billiard lattice model considered in Gaspard and Gilbert (2009 J. Stat. Mech.: Theory Exp. 2009 24), and hence provide a first step in the derivation of a macroscopic heat equation for a microscopic stochastic evolution of mechanical origin. (paper)

  9. Automatic Strain-Rate Controller,

    Science.gov (United States)

    1976-12-01

    D—AO37 9~e2 ROME AIR DEVELOPMENT CENTER GRIFFISS AFB N 1’ FIG 13/ 6AUTOMATIC STRAIN—RATE CONTROLLER, (U) DEC 76 R L HUNTSINGER. J A ADAMSK I...goes to zero. CONTROLLER, Leeds and Northrup Series 80 CAT with proportional band , rate , reset, and approach controls . Input from deviation output...8) through ( 16) . (8) Move the set-point slowl y up to 3 or 4. (9) If the recorder po inter hunts , adjust the func t ion controls on tine Ser

  10. ANALYSIS OF MEASURES FOR INCREASING THE RATING OF UNIVERSITY IN INTERNATIONAL RATING SYSTEM

    Directory of Open Access Journals (Sweden)

    В.П. Харченко

    2011-02-01

    Full Text Available The principles of forming the world's most popular international Internet-ranking of universities are considered. The principles of forming the international rating of electronic resources known as Webometrics, which results are defined by summing four values based on quantity of unique external links to the site page and by the quantity of “valuable” files placed on website are represented.  Мost Internet ratings make slope on the  Web activity of the university and its researchers, therefore the participation of entire staff at university is required

  11. Large Scale System Safety Integration for Human Rated Space Vehicles

    Science.gov (United States)

    Massie, Michael J.

    2005-12-01

    concurrence on these non-compliant conditionsAnother area of challenge lies in determining the credibility of a proposed hazard. For example, NASA's definition of a credible hazard is accurate but does not provide specific guidance about contractors declaring a hazard "not credible" and ceasing working on that item.Unfortunately, this has the side effect of taking valuable resources from high-risk areas and using them to investigate whether these extremely low risk items have the potential to become worse than they appear.In order to deal with these types of issues, there must exist the concept of a "Safe State" and it must be used as a building block to help address many of the technical and social challenges in working safety and risk management. This "Safe State" must serve as the foundation for building the cultural modifications needed to assure that safety issues are properly identified, heard, and dispositioned by our space program management.As the space program and the countries involved in it move forward in development of human rated spacecraft, they must learn from the recent Columbia accident and establish new/modified basis for safety risk decisions. Those involved must also become more cognizant of the diversity in safety approaches and agree on how to deal with them. Most of all, those involved must never forget that while the System Safety duty maybe difficult, their efforts help to preserve the lives of space crews and their families.

  12. A generalized window energy rating system for typical office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Cheng; Chen, Tingyao; Yang, Hongxing; Chung, Tse-ming [Research Center for Building Environmental Engineering, Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong (China)

    2010-07-15

    Detailed computer simulation programs require lengthy inputs, and cannot directly provide an insight to relationship between the window energy performance and the key window design parameters. Hence, several window energy rating systems (WERS) for residential houses and small buildings have been developed in different countries. Many studies showed that utilization of daylight through elaborate design and operation of windows leads to significant energy savings in both cooling and lighting in office buildings. However, the current WERSs do not consider daylighting effect, while most of daylighting analyses do not take into account the influence of convective and infiltration heat gains. Therefore, a generalized WERS for typical office buildings has been presented, which takes all primary influence factors into account. The model includes embodied and operation energy uses and savings by a window to fully reflect interactions among the influence parameters. Reference locations selected for artificial lighting and glare control in the current common simulation practice may cause uncompromised conflicts, which could result in over- or under-estimated energy performance. Widely used computer programs, DOE2 and ADELINE, for hourly daylighting and cooling simulations have their own weaknesses, which may result in unrealistic or inaccurate results. An approach is also presented for taking the advantages of the both programs and avoiding their weaknesses. The model and approach have been applied to a typical office building of Hong Kong as an example to demonstrate how a WERS in a particular location can be established and how well the model can work. The energy effect of window properties, window-to-wall ratio (WWR), building orientation and lighting control strategies have been analyzed, and can be indicated by the localized WERS. An application example also demonstrates that the algebraic WERS derived from simulation results can be easily used for the optimal design of

  13. Design of mass flow rate measurement system for SST-1 superconducting magnet system

    Energy Technology Data Exchange (ETDEWEB)

    Varmora, P., E-mail: pvamora@ipr.res.in; Sharma, A.N.; Khristi, Y.; Prasad, U.; Patel, D.; Doshi, K.; Pradhan, S.

    2016-11-15

    Highlights: • Design of Venturi meter for SST-1 magnet system. • Details of Helium mass flow measurement system used in SST-1. • Instruments and measurement techniques for flow measurement. • VME based data acquisition system details and flow calculation and results from SST-1 campaigns. - Abstract: Superconducting Magnet System (SCMS) of Steady State Superconducting Tokamak – 1 (SST-1) is forced-flow cooled by a closed cycle 1.3 kW (at 4.5 K) class Helium Refrigerator cum Liquefier (HRL) system. An accurate measurement of helium mass flow rate in different coils is required to ensure the uniform cooling of the cold mass in the entire range of operating temperature (300 K to 4.5 K) and pressure (0.9–0.4 MPa). To meet this requirement, indigenously designed and fabricated venturi meters are installed on 27 different coils of SST-1 SCMS. A VME based Data Acquisition System (DAS) has been developed and used to acquire the flow measurement data from different flowmeters. The details of the design of venturi meter, its different measurement and signal conditioning components, the data acquisition system and the mass flow rate calculation method are described in this paper. The mass flow rate measurement data from cryogenic acceptance and SST-1 magnet commissioning experiments are also presented and discussed in this paper.

  14. Design of mass flow rate measurement system for SST-1 superconducting magnet system

    International Nuclear Information System (INIS)

    Varmora, P.; Sharma, A.N.; Khristi, Y.; Prasad, U.; Patel, D.; Doshi, K.; Pradhan, S.

    2016-01-01

    Highlights: • Design of Venturi meter for SST-1 magnet system. • Details of Helium mass flow measurement system used in SST-1. • Instruments and measurement techniques for flow measurement. • VME based data acquisition system details and flow calculation and results from SST-1 campaigns. - Abstract: Superconducting Magnet System (SCMS) of Steady State Superconducting Tokamak – 1 (SST-1) is forced-flow cooled by a closed cycle 1.3 kW (at 4.5 K) class Helium Refrigerator cum Liquefier (HRL) system. An accurate measurement of helium mass flow rate in different coils is required to ensure the uniform cooling of the cold mass in the entire range of operating temperature (300 K to 4.5 K) and pressure (0.9–0.4 MPa). To meet this requirement, indigenously designed and fabricated venturi meters are installed on 27 different coils of SST-1 SCMS. A VME based Data Acquisition System (DAS) has been developed and used to acquire the flow measurement data from different flowmeters. The details of the design of venturi meter, its different measurement and signal conditioning components, the data acquisition system and the mass flow rate calculation method are described in this paper. The mass flow rate measurement data from cryogenic acceptance and SST-1 magnet commissioning experiments are also presented and discussed in this paper.

  15. Achievable Performance of Zero-Delay Variable-Rate Coding in Rate-Constrained Networked Control Systems with Channel Delay

    DEFF Research Database (Denmark)

    Barforooshan, Mohsen; Østergaard, Jan; Stavrou, Fotios

    2017-01-01

    This paper presents an upper bound on the minimum data rate required to achieve a prescribed closed-loop performance level in networked control systems (NCSs). The considered feedback loop includes a linear time-invariant (LTI) plant with single measurement output and single control input. Moreover......, in this NCS, a causal but otherwise unconstrained feedback system carries out zero-delay variable-rate coding, and control. Between the encoder and decoder, data is exchanged over a rate-limited noiseless digital channel with a known constant time delay. Here we propose a linear source-coding scheme...

  16. Correlation of the Rock Mass Rating (RMR) System with the Unified Soil Classification System (USCS): Introduction of the Weak Rock Mass Rating System (W-RMR)

    Science.gov (United States)

    Warren, Sean N.; Kallu, Raj R.; Barnard, Chase K.

    2016-11-01

    Underground gold mines in Nevada are exploiting increasingly deeper ore bodies comprised of weak to very weak rock masses. The Rock Mass Rating (RMR) classification system is widely used at underground gold mines in Nevada and is applicable in fair to good-quality rock masses, but is difficult to apply and loses reliability in very weak rock mass to soil-like material. Because very weak rock masses are transition materials that border engineering rock mass and soil classification systems, soil classification may sometimes be easier and more appropriate to provide insight into material behavior and properties. The Unified Soil Classification System (USCS) is the most likely choice for the classification of very weak rock mass to soil-like material because of its accepted use in tunnel engineering projects and its ability to predict soil-like material behavior underground. A correlation between the RMR and USCS systems was developed by comparing underground geotechnical RMR mapping to laboratory testing of bulk samples from the same locations, thereby assigning a numeric RMR value to the USCS classification that can be used in spreadsheet calculations and geostatistical analyses. The geotechnical classification system presented in this paper including a USCS-RMR correlation, RMR rating equations, and the Geo-Pick Strike Index is collectively introduced as the Weak Rock Mass Rating System (W-RMR). It is the authors' hope that this system will aid in the classification of weak rock masses and more usable design tools based on the RMR system. More broadly, the RMR-USCS correlation and the W-RMR system help define the transition between engineering soil and rock mass classification systems and may provide insight for geotechnical design in very weak rock masses.

  17. Safety Characteristics in System Application Software for Human Rated Exploration

    Science.gov (United States)

    Mango, E. J.

    2016-01-01

    NASA and its industry and international partners are embarking on a bold and inspiring development effort to design and build an exploration class space system. The space system is made up of the Orion system, the Space Launch System (SLS) and the Ground Systems Development and Operations (GSDO) system. All are highly coupled together and dependent on each other for the combined safety of the space system. A key area of system safety focus needs to be in the ground and flight application software system (GFAS). In the development, certification and operations of GFAS, there are a series of safety characteristics that define the approach to ensure mission success. This paper will explore and examine the safety characteristics of the GFAS development.

  18. A packet-based dual-rate PID control strategy for a slow-rate sensing Networked Control System.

    Science.gov (United States)

    Cuenca, A; Alcaina, J; Salt, J; Casanova, V; Pizá, R

    2018-05-01

    This paper introduces a packet-based dual-rate control strategy to face time-varying network-induced delays, packet dropouts and packet disorder in a Networked Control System. Slow-rate sensing enables to achieve energy saving and to avoid packet disorder. Fast-rate actuation makes reaching the desired control performance possible. The dual-rate PID controller is split into two parts: a slow-rate PI controller located at the remote side (with no permanent communication to the plant) and a fast-rate PD controller located at the local side. The remote side also includes a prediction stage in order to generate the packet of future, estimated slow-rate control actions. These actions are sent to the local side and converted to fast-rate ones to be used when a packet does not arrive at this side due to the network-induced delay or due to occurring dropouts. The proposed control solution is able to approximately reach the nominal (no-delay, no-dropout) performance despite the existence of time-varying delays and packet dropouts. Control system stability is ensured in terms of probabilistic Linear Matrix Inequalities (LMIs). Via real-time control for a Cartesian robot, results clearly reveal the superiority of the control solution compared to a previous proposal by authors. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.

  19. Overview of gynecomastia in the modern era and the Leeds Gynaecomastia Investigation algorithm.

    Science.gov (United States)

    Rahmani, Samir; Turton, Philip; Shaaban, Abeer; Dall, Barbara

    2011-01-01

    Gynecomastia is a benign enlargement of male breast glandular tissue. At least a third of males are affected at some time during their lifetime. Idiopathic causes exceed other etiologies and relate to an imbalance in the ratio of estrogen to androgen tissue levels or end-organ responsiveness to these hormones. Assessment must include a thorough history and clinical examination, specific blood investigations and usually tissue sampling and/or breast imaging. Management consists of a combination of measures that may include simple reassurance, pharmacological manipulation, medical treatment or surgery. Hormone therapy may help to abort the acute proliferative phase of gynecomastia with a 30% response rate but should not be considered in chronic established cases. Surgical treatment may comprise simple liposuction for a predominant fatty component or direct excision when glandular tissue is predominant. The main aim is to control the patient's symptoms and to exclude other etiological factors. © 2011 Wiley Periodicals, Inc.

  20. 78 FR 58153 - Prevailing Rate Systems; North American Industry Classification System Based Federal Wage System...

    Science.gov (United States)

    2013-09-23

    ... American Industry Classification System Based Federal Wage System Wage Surveys AGENCY: U.S. Office of... in Federal Wage System wage survey industry regulations with the 2012 NAICS revisions published by.... Applicability date: This rule applies for local wage surveys beginning on or after February 21, 2014. FOR...

  1. Effectiveness of daylighting design and occupant visual satisfaction in a LEED gold laboratory building

    Energy Technology Data Exchange (ETDEWEB)

    Hua, Ying; Oswald, Anne [Department of Design and Environmental Analysis, Cornell University, Ithaca, NY 14853 (United States); Yang, Xiaodi [School of Architecture, Carnegie Mellon University, Pittsburgh, PA 15213 (United States)

    2011-01-15

    Using daylight as primary light source has been widely recognized as an important strategy to reduce building energy demand and enhance indoor environment quality. However, to design and operate a building to make full use of daylight, which is a dynamic light source, to meet diverse occupant needs remains a challenge. This paper reports a post-occupancy study of the visual environment in a laboratory building on a university campus, and puts a spotlight on the building occupants as it examines the effectiveness of the daylighting design and systems integration in creating a visual environment to support occupant comfort and satisfaction while reducing artificial lighting demand. Results show generally high satisfaction with daylit work environment and positive effect of the horizontal shading strategy. Issues about the integration between daylighting and electric lighting systems and level of occupant control are identified and discussed for improving the effectiveness of daylighting and enhancing the quality of the visual environment in the building of study. A multiple-tool methodology is developed and tested, which included occupant surveys, interviews, illuminance measurements, continuous data loggers, fisheye-lens camera and glare-identifying software, and documentation of spatial settings, systems features, and user behavior. (author)

  2. System reliability evaluation of a touch panel manufacturing system with defect rate and reworking

    International Nuclear Information System (INIS)

    Lin, Yi-Kuei; Huang, Cheng-Fu; Chang, Ping-Chen

    2013-01-01

    In recent years, portable consumer electronic products, such as cell phone, GPS, digital camera, tablet PC, and notebook are using touch panel as interface. With the demand of touch panel increases, performance assessment is essential for touch panel production. This paper develops a method to evaluate system reliability of a touch panel manufacturing system (TPMS) with defect rate of each workstation and takes reworking actions into account. The system reliability which evaluates the possibility of demand satisfaction can provide to managers with an understanding of the system capability and can indicate possible improvements. First, we construct a capacitated manufacturing network (CMN) for a TPMS. Second, a decomposition technique is developed to determine the input flow of each workstation based on the CMN. Finally, we generate the minimal capacity vectors that should be provided to satisfy the demand. The system reliability is subsequently evaluated in terms of the minimal capacity vectors. A further decision making issue is discussed to decide a reliable production strategy. -- Graphical abstract: The proposed procedure to evaluate system reliability of the touch panel manufacturing system (TPMS). Highlights: • The system reliability of a touch panel manufacturing system (TPMS) is evaluated. • The reworking actions are taken into account in the TPMS. • A capacitated manufacturing network is constructed for the TPMS. • A procedure is proposed to evaluate system reliability of TPMS

  3. Flow rate control systems for coolants for BWR type reactors

    International Nuclear Information System (INIS)

    Igarashi, Yoko; Kato, Naoyoshi.

    1981-01-01

    Purpose: To increase spontaneous recycling flow rate of coolants in BWR type reactors when the water level in the reactor decreases, by communicating a downcomer with a lower plenum. Constitution: An opening is provided to the back plate disposed at the lower end of a reactor core shroud for communicating a downcomer with a lower plenum, and an ON-OFF valve actuated by an operation rod is provided to the opening. When abnormal water level or pressure in the reactor is detected by a level metal or pressure meter, the operation rod is driven to open the ON-OFF valve, whereby coolants fed from a jet pump partially flows through the opening to increase the spontaneous recycling flow rate of the coolants. This can increase the spontaneous recycling flow rate of the coolants upon spontaneous recycling operation, thereby maintaining the reactor safety and the fuel soundness. (Moriyama, K.)

  4. 38 CFR 4.104 - Schedule of ratings-cardiovascular system.

    Science.gov (United States)

    2010-07-01

    ...-cardiovascular system. 4.104 Section 4.104 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS SCHEDULE FOR RATING DISABILITIES Disability Ratings The Cardiovascular System § 4.104 Schedule of ratings—cardiovascular system. Diseases of the Heart Rating Note (1): Evaluate cor pulmonale, which is a form of...

  5. 38 CFR 4.97 - Schedule of ratings-respiratory system.

    Science.gov (United States)

    2010-07-01

    ...-respiratory system. 4.97 Section 4.97 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS SCHEDULE FOR RATING DISABILITIES Disability Ratings The Respiratory System § 4.97 Schedule of ratings—respiratory system. Rating DISEASES OF THE NOSE AND THROAT 6502Septum, nasal, deviation of: Traumatic only...

  6. Capital Controls and Foreign Investor Subsidies Implicit in South Africa's Dual Exchange Rate System

    NARCIS (Netherlands)

    Huizinga, H.P.; Schaling, E.; van der Windt, P.C.

    2007-01-01

    Both in theory and practice, capital controls and dual exchange rate systems can be part of a country's optimal tax policy. We first show how a dual exchange rate system can be interpreted as a tax (or subsidy) on international capital income. We show that a dual exchange rate system, with separate

  7. 75 FR 81138 - Medicare Program; Home Health Prospective Payment System Rate Update for Calendar Year 2011...

    Science.gov (United States)

    2010-12-27

    ... [CMS-1510-CN2] RIN 0938-AP88 Medicare Program; Home Health Prospective Payment System Rate Update for... ``Medicare Program; Home Health Prospective Payment System Rate Update for Calendar Year 2011; Changes in... Prospective Payment System Rate Update for Calendar Year 2011; Changes in Certification Requirements for Home...

  8. 76 FR 68525 - Medicare Program; Home Health Prospective Payment System Rate Update for Calendar Year 2012

    Science.gov (United States)

    2011-11-04

    ... Prospective Payment System Rate Update for Calendar Year 2012; Final Rule #0;#0;Federal Register / Vol. 76, No... 0938-AQ30 Medicare Program; Home Health Prospective Payment System Rate Update for Calendar Year 2012... sets forth updates to the home health prospective payment system (HH PPS) rates, including: the...

  9. 75 FR 76293 - Medicare Program; Home Health Prospective Payment System Rate Update for Calendar Year 2011...

    Science.gov (United States)

    2010-12-08

    ... [CMS-1510-CN] RIN 0938-AP88 Medicare Program; Home Health Prospective Payment System Rate Update for... Health Prospective Payment System Rate Update for Calendar Year 2011; Changes in Certification... effective as if they had been included in the Medicare Program; Home Health Prospective Payment System Rate...

  10. 38 CFR 4.119 - Schedule of ratings-endocrine system.

    Science.gov (United States)

    2010-07-01

    ... minute), eye involvement, muscular weakness, loss of weight, and sympathetic nervous system...-endocrine system. 4.119 Section 4.119 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS SCHEDULE FOR RATING DISABILITIES Disability Ratings The Endocrine System § 4.119 Schedule of ratings...

  11. Expert System Constant False Alarm Rate (CFAR) Processor

    National Research Council Canada - National Science Library

    Wicks, Michael C

    2006-01-01

    An artificial intelligence system improves radar signal processor performance by increasing target probability of detection and reducing probability of false alarm in a severe radar clutter environment...

  12. On the equivalence between the minimum entropy generation rate and the maximum conversion rate for a reactive system

    International Nuclear Information System (INIS)

    Bispo, Heleno; Silva, Nilton; Brito, Romildo; Manzi, João

    2013-01-01

    Highlights: • Minimum entropy generation (MEG) principle improved the reaction performance. • MEG rate and the maximum conversion equivalence have been analyzed. • Temperature and residence time are used to the domain establishment of MEG. • Satisfying the temperature and residence time relationship results a optimal performance. - Abstract: The analysis of the equivalence between the minimum entropy generation (MEG) rate and the maximum conversion rate for a reactive system is the main purpose of this paper. While being used as a strategy of optimization, the minimum entropy production was applied to the production of propylene glycol in a Continuous Stirred-Tank Reactor (CSTR) with a view to determining the best operating conditions, and under such conditions, a high conversion rate was found. The effects of the key variables and restrictions on the validity domain of MEG were investigated, which raises issues that are included within a broad discussion. The results from simulations indicate that from the chemical reaction standpoint a maximum conversion rate can be considered as equivalent to MEG. Such a result can be clearly explained by examining the classical Maxwell–Boltzmann distribution, where the molecules of the reactive system under the condition of the MEG rate present a distribution of energy with reduced dispersion resulting in a better quality of collision between molecules with a higher conversion rate

  13. 76 FR 39159 - Schedule for Rating Disabilities; The Digestive System

    Science.gov (United States)

    2011-07-05

    ... of this change is to incorporate medical advances that have occurred since the last review, insert current medical terminology, and provide clear criteria. DATES: Comments must be received by VA on or... the rating schedule, and implement current medical criteria and terminology that reflect recent...

  14. A new system for rating impact sound insulation

    NARCIS (Netherlands)

    Gerretsen, E.

    1976-01-01

    The rating of impact sound insulation on the basis of tapping machine measurements with the ISO reference values has proved to be unsatisfactory in practice. This is mainly due to the differences in spectrum shape of tapping machine noise and real life impact noises, such as walking. The problem can

  15. Survival rates in bankruptcy systems : overlooking the evidence

    NARCIS (Netherlands)

    Couwenberg, Oscar

    2001-01-01

    Extensive research on bankruptcy still has not made it possible to end the efficiency discussion concerning the need for a reorganization provision in bankruptcy laws. In this paper, I discuss the pervasiveness of asset sales in bankruptcy procedures and the effect it has on survival rates. Without

  16. System Identification of a Non-Uniformly Sampled Multi-Rate System in Aluminium Electrolysis Cells

    Directory of Open Access Journals (Sweden)

    Håkon Viumdal

    2014-07-01

    Full Text Available Standard system identification algorithms are usually designed to generate mathematical models with equidistant sampling instants, that are equal for both input variables and output variables. Unfortunately, real industrial data sets are often disrupted by missing samples, variations of sampling rates in the different variables (also known as multi-rate systems, and intermittent measurements. In industries with varying events based maintenance or manual operational measures, intermittent measurements are performed leading to uneven sampling rates. Such is the case with aluminium smelters, where in addition the materials fed into the cell create even more irregularity in sampling. Both measurements and feeding are mostly manually controlled. A simplified simulation of the metal level in an aluminium electrolysis cell is performed based on mass balance considerations. System identification methods based on Prediction Error Methods (PEM such as Ordinary Least Squares (OLS, and the sub-space method combined Deterministic and Stochastic system identification and Realization (DSR, and its variants are applied to the model of a single electrolysis cell as found in the aluminium smelters. Aliasing phenomena due to large sampling intervals can be crucial in avoiding unsuitable models, but with knowledge about the system dynamics, it is easier to optimize the sampling performance, and hence achieve successful models. The results based on the simulation studies of molten aluminium height in the cells using the various algorithms give results which tally well with the synthetic data sets used. System identification on a smaller data set from a real plant is also implemented in this work. Finally, some concrete suggestions are made for using these models in the smelters.

  17. Exchange rate system and policy in the present world

    OpenAIRE

    Grubišić Zoran

    2005-01-01

    The choice of exchange rate regime is important, not only in terms of its effect on trade flows, but also with respect to inflation expectations. Countries facing disinflation may find that pegs regimes are more appropriate solution. But where the trade balance account is significantly deteriorated and growth has been sluggish, a more flexible regime might be called for. The natural classification in eighties and early nineties suggests that intermediate regimes may provide important advantag...

  18. Exchange rate system and policy in the present world

    Directory of Open Access Journals (Sweden)

    Grubišić Zoran

    2005-01-01

    Full Text Available The choice of exchange rate regime is important, not only in terms of its effect on trade flows, but also with respect to inflation expectations. Countries facing disinflation may find that pegs regimes are more appropriate solution. But where the trade balance account is significantly deteriorated and growth has been sluggish, a more flexible regime might be called for. The natural classification in eighties and early nineties suggests that intermediate regimes may provide important advantages – to capture some of the benefits of both extremes while avoiding many of the costs. However today many experts predicted that exchange rate regimes would move in a "bipolar" manner to the extremes of "hard" pegs or free floats. An increasing number of countries did announce their intent to allow greater exchange rate flexibility. But, in practice, countries had a "fear of floating ". Distinction is made among advanced, emerging and other developing countries. Emerging markets have stronger links to international capital markets than do other developing economies. Thus, while non-emerging market developing economies may gain credibility through pegging their exchange rates, emerging markets find it harder to do so and could benefit from investing in "learning to float". More advanced economies with their access to international capital market are best positioned to enjoy the benefits of flexibility. It is found that the proportion of countries adopting intermediate regimes has indeed been shrinking in favor of greater flexibility or greater fixity, especially for countries more integrated with international markets. But, there is no final conclusion on the idea that intermediate regimes will dissapear.

  19. An expert system for the esthetic rating of bridges.

    Science.gov (United States)

    1990-01-01

    The expert system presented should facilitate the in-depth analysis of bridge esthetics and encourage high standards for the appearance of bridges. The procedure described systematically evaluates features of a target bridge in relation to a similar ...

  20. Executive Information System Modelling to Monitor Indonesian Criminal Rate

    Directory of Open Access Journals (Sweden)

    Josef Bernadi

    2016-05-01

    Full Text Available Similar to any other governments, Indonesia government has the role of protecting the security of its citizens via the established police unit. However, the executive unit is often unable to provide response in timely manner due to the huge data size. For the reason, an executive information system (EIS is established in order to provide necessary information to leverage the decision making process. This work intends to establish and evaluate the executive information system and its support to facilitate the efforts to fight crimes in Indonesia territory. The EIS prototype is established and is evaluated on the basis of the six information system success factors where the required data are collected by means of questionnaire. The results suggest that the factors of system quality, information quality, easy-of-use, user satisfaction, and individual and organization impacts are very significant.

  1. High rate amplifier-digitizer system for liquid argon calorimeters

    International Nuclear Information System (INIS)

    Droege, T.F.; Lobkowicz, F.; Fukushima, Y.

    1978-01-01

    A low-cost charge amplifier for a liquid argon photon detector and a new method for pulse height analysis are described. This scheme is suitable for high-energy photon detection with high counting rate. Samples of preamplifer output are taken just before and just after the arrival of the charge from the detector. The difference of these samples provides a stable pedestal and rejects low frequency noise. Short two-pulse resolving time (approximately equal to 200ns) is achieved. 6 refs

  2. Calculating Outcrossing Rates used in Decision Support Systems for Ships

    DEFF Research Database (Denmark)

    Nielsen, Ulrik Dam

    2008-01-01

    Onboard decision support systems (DSS) are used to increase the operational safety of ships. Ideally, DSS can estimate - in the statistical sense - future ship responses on a time scale of the order of 1-3 hours taking into account speed and course changes. The calculations depend on both...... analysis, and the paper derives and describes the main ideas. The concept is illustrated by an example, where the limit state of a non-linear ship response is considered. The results from the parallel system analysis are in agreement with corresponding Monte Carlo simulations. However, the computational...

  3. Secret-key rates and privacy leakage in biometric systems

    NARCIS (Netherlands)

    Ignatenko, T.

    2009-01-01

    In this thesis both the generation of secret keys from biometric data and the binding of secret keys to biometric data are investigated. These secret keys can be used to regulate access to sensitive data, services, and environments. In a biometric secrecy system a secret key is generated or chosen

  4. 78 FR 60182 - Prevailing Rate Systems; Definition of Broward County, Florida, to a Nonappropriated Fund Federal...

    Science.gov (United States)

    2013-10-01

    ... OFFICE OF PERSONNEL MANAGEMENT 5 CFR Part 532 RIN 3206-AM83 Prevailing Rate Systems; Definition of... wage area. The Federal Prevailing Rate Advisory Committee, the national labor-management committee... follows: PART 532--PREVAILING RATE SYSTEMS 0 1. The authority citation for part 532 continues to read as...

  5. 78 FR 29658 - Prevailing Rate Systems; Definition of Broward County, Florida, to a Nonappropriated Fund Federal...

    Science.gov (United States)

    2013-05-21

    ... OFFICE OF PERSONNEL MANAGEMENT 5 CFR Part 532 RIN 3206-AM83 Prevailing Rate Systems; Definition of... and Palm Beach Counties, FL. The Federal Prevailing Rate Advisory Committee, the national labor... 532--PREVAILING RATE SYSTEMS 0 1. The authority citation for part 532 continues to read as follows...

  6. 77 FR 9226 - Physical Systems Integration, LLC; Supplemental Notice That Initial Market-Based Rate Filing...

    Science.gov (United States)

    2012-02-16

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. ER12-1013-000] Physical Systems Integration, LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes Request for... Physical Systems Integration, LLC's application for market-based rate authority, with an accompanying rate...

  7. Adaptive discrete rate and power transmission for spectrum sharing systems

    KAUST Repository

    Abdallah, Mohamed M.

    2012-04-01

    In this paper we develop a framework for optimizing the performance of the secondary link in terms of the average spectral efficiency assuming quantized channel state information (CSI) of the secondary and the secondary-to-primary interference channels available at the secondary transmitter. We consider the problem under the constraints of maximum average interference power levels at the primary receiver. We develop a sub-optimal computationally efficient iterative algorithm for finding the optimal CSI quantizers as well as the discrete power and rate employed at the cognitive transmitter for each quantized CSI level so as to maximize the average spectral efficiency. We show via analysis and simulations that the proposed algorithm converges for Rayleigh fading channels. Our numerical results give the number of bits required to sufficiently represent the CSI to achieve almost the maximum average spectral efficiency attained using full knowledge of the CSI. © 2012 IEEE.

  8. A cross sectional study investigating the association between exposure to food outlets and childhood obesity in Leeds, UK.

    Science.gov (United States)

    Griffiths, Claire; Frearson, Anna; Taylor, Adam; Radley, Duncan; Cooke, Carlton

    2014-12-06

    Current UK policy in relation to the influence of the 'food environment' on childhood obesity appears to be driven largely on assumptions or speculations because empirical evidence is lacking and findings from studies are inconsistent. The aim of this study was to investigate the number of food outlets and the proximity of food outlets in the same sample of children, without solely focusing on fast food. Cross sectional study over 3 years (n = 13,291 data aggregated). Body mass index (BMI) was calculated for each participant, overweight and obesity were defined as having a BMI >85(th) (sBMI 1.04) and 95(th) (sBMI 1.64) percentiles respectively (UK90 growth charts). Home and school neighbourhoods were defined as circular buffers with a 2 km Euclidean radius, centred on these locations. Commuting routes were calculated using the shortest straight line distance, with a 2 km buffer to capture varying routes. Data on food outlet locations was sourced from Leeds City Council covering the study area and mapped against postcode. Food outlets were categorised into three groups, supermarkets, takeaway and retail. Proximity to the nearest food outlet in the home and school environmental domain was also investigated. Age, gender, ethnicity and deprivation (IDACI) were included as covariates in all models. There is no evidence of an association between the number of food outlets and childhood obesity in any of these environments; Home Q4 vs. Q1 OR = 1.11 (95% CI = 0.95-1.30); School Q4 vs. Q1 OR = 1.00 (95% CI 0.87 - 1.16); commute Q4 vs. Q1 OR = 0.1.00 (95% CI 0.83 - 1.20). Similarly there is no evidence of an association between the proximity to the nearest food outlet and childhood obesity in the home (OR = 0.77 [95% CI = 0.61 - 0.98]) or the school (OR = 1.01 [95% CI 0.84 - 1.23]) environment. This study provides little support for the notion that exposure to food outlets in the home, school and commuting neighbourhoods increase the risk of obesity

  9. A good complaints system

    African Journals Online (AJOL)

    system for handling complaints. While complaints often provide invaluable feedback on an individual's performance, they also offer dissatisfied patients an opportunity to air their views. Even if a complaint .... Communications Manager, Medical. Protection Society, Victoria House,. 2 Victoria Place, Leeds, UK. Pieter Carstens.

  10. Predicting prey population dynamics from kill rate, predation rate and predator-prey ratios in three wolf-ungulate systems.

    Science.gov (United States)

    Vucetich, John A; Hebblewhite, Mark; Smith, Douglas W; Peterson, Rolf O

    2011-11-01

    1. Predation rate (PR) and kill rate are both fundamental statistics for understanding predation. However, relatively little is known about how these statistics relate to one another and how they relate to prey population dynamics. We assess these relationships across three systems where wolf-prey dynamics have been observed for 41 years (Isle Royale), 19 years (Banff) and 12 years (Yellowstone). 2. To provide context for this empirical assessment, we developed theoretical predictions of the relationship between kill rate and PR under a broad range of predator-prey models including predator-dependent, ratio-dependent and Lotka-Volterra dynamics. 3. The theoretical predictions indicate that kill rate can be related to PR in a variety of diverse ways (e.g. positive, negative, unrelated) that depend on the nature of predator-prey dynamics (e.g. structure of the functional response). These simulations also suggested that the ratio of predator-to-prey is a good predictor of prey growth rate. That result motivated us to assess the empirical relationship between the ratio and prey growth rate for each of the three study sites. 4. The empirical relationships indicate that PR is not well predicted by kill rate, but is better predicted by the ratio of predator-to-prey. Kill rate is also a poor predictor of prey growth rate. However, PR and ratio of predator-to-prey each explained significant portions of variation in prey growth rate for two of the three study sites. 5. Our analyses offer two general insights. First, Isle Royale, Banff and Yellowstone are similar insomuch as they all include wolves preying on large ungulates. However, they also differ in species diversity of predator and prey communities, exploitation by humans and the role of dispersal. Even with the benefit of our analysis, it remains difficult to judge whether to be more impressed by the similarities or differences. This difficulty nicely illustrates a fundamental property of ecological

  11. 78 FR 29657 - Prevailing Rate Systems; Definition of Vanderburgh County, Indiana, to a Nonappropriated Fund...

    Science.gov (United States)

    2013-05-21

    ...-AM82 Prevailing Rate Systems; Definition of Vanderburgh County, Indiana, to a Nonappropriated Fund... County, IN; and Jefferson and Pulaski Counties, MO. The Federal Prevailing Rate Advisory Committee, the... as follows: [[Page 29658

  12. Bit Error Rate Minimizing Channel Shortening Equalizers for Single Carrier Cyclic Prefixed Systems

    National Research Council Canada - National Science Library

    Martin, Richard K; Vanbleu, Koen; Ysebaert, Geert

    2007-01-01

    .... Previous work on channel shortening has largely been in the context of digital subscriber lines, a wireline system that allows bit allocation, thus it has focused on maximizing the bit rate for a given bit error rate (BER...

  13. 76 FR 9502 - Medicare Program; Home Health Prospective Payment System Rate Update for Calendar Year 2011...

    Science.gov (United States)

    2011-02-18

    ... [CMS-1510-F2] RIN 0938-AP88 Medicare Program; Home Health Prospective Payment System Rate Update for... set forth an update to the Home Health Prospective Payment System (HH PPS) rates, including: The... the Medicare prospective payment system for HHAs. This correcting amendment corrects a technical error...

  14. A Text Steganographic System Based on Word Length Entropy Rate

    Directory of Open Access Journals (Sweden)

    Francis Xavier Kofi Akotoye

    2017-10-01

    Full Text Available The widespread adoption of electronic distribution of material is accompanied by illicit copying and distribution. This is why individuals, businesses and governments have come to think of how to protect their work, prevent such illicit activities and trace the distribution of a document. It is in this context that a lot of attention is being focused on steganography. Implementing steganography in text document is not an easy undertaking considering the fact that text document has very few places in which to embed hidden data. Any minute change introduced to text objects can easily be noticed thus attracting attention from possible hackers. This study investigates the possibility of embedding data in text document by employing the entropy rate of the constituent characters of words not less than four characters long. The scheme was used to embed bits in text according to the alphabetic structure of the words, the respective characters were compared with their neighbouring characters and if the first character was alphabetically lower than the succeeding character according to their ASCII codes, a zero bit was embedded otherwise 1 was embedded after the characters had been transposed. Before embedding, the secret message was encrypted with a secret key to add a layer of security to the secret message to be embedded, and then a pseudorandom number was generated from the word counts of the text which was used to paint the starting point of the embedding process. The embedding capacity of the scheme was relatively high compared with the space encoding and semantic method.

  15. Fuzzy production planning models for an unreliable production system with fuzzy production rate and stochastic/fuzzy demand rate

    Directory of Open Access Journals (Sweden)

    K. A. Halim

    2011-01-01

    Full Text Available In this article, we consider a single-unit unreliable production system which produces a single item. During a production run, the production process may shift from the in-control state to the out-of-control state at any random time when it produces some defective items. The defective item production rate is assumed to be imprecise and is characterized by a trapezoidal fuzzy number. The production rate is proportional to the demand rate where the proportionality constant is taken to be a fuzzy number. Two production planning models are developed on the basis of fuzzy and stochastic demand patterns. The expected cost per unit time in the fuzzy sense is derived in each model and defuzzified by using the graded mean integration representation method. Numerical examples are provided to illustrate the optimal results of the proposed fuzzy models.

  16. Silicon Detector System for High Rate EXAFS Applications.

    Science.gov (United States)

    Pullia, A; Kraner, H W; Siddons, D P; Furenlid, L R; Bertuccio, G

    1995-08-01

    A multichannel silicon pad detector for EXAFS (Extended X-ray Absorption Fine Structure) applications has been designed and built. The X-ray spectroscopic measurements demonstrate that an adequate energy resolution of 230 eV FWHM (corresponding to 27 rms electrons in silicon) can be achieved reliably at -35 °C. A resolution of 190 eV FWHM (corresponding to 22 rms electrons) has been obtained from individual pads at -35 °C. At room temperature (25 °C) an average energy resolution of 380 eV FWHM is achieved and a resolution of 350 eV FWHM (41 rms electrons) is the best performance. A simple cooling system constituted of Peltier cells is sufficient to reduce the reverse currents of the pads and their related shot noise contribution, in order to achieve resolutions better than 300 eV FWHM which is adequate for the EXAFS applications.

  17. ''House in park'' gold plated. Subsequent certification for the new office building; ''Haus im Park'' vergoldet. Nachtraegliche LEED-Zertifizierung fuer neues Buerogebaeude

    Energy Technology Data Exchange (ETDEWEB)

    Herzog, Kati; Wildhack, Alice [Bilfinger Berger AG, Mannheim (Germany). Abt. Nachhaltigkeit/Energieeffizienz

    2011-07-01

    In March 2011, the ''house in park'' received the signet LEED {sup registered} of the U.S. Green Building Council (Washington, North Carolina, U.S.A.) in ''gold''. In general, it is the second German project that was awarded with ''gold'' in the certification version ''New Construction, version 2009''. The special challenge: In the planning phase, no aspects relevant to planning and execution with regard to LEED were implemented. In total there are 15 LEED-certified buildings actually in Germany (worldwide: 7,894). 115 Projects are registered (worldwide: 23,238). The trend is increasing, both nationally as well as internationally.

  18. Choice of optimal exchange rate system For the Republic of Croatia

    OpenAIRE

    Dražen Koški

    2008-01-01

    The aim of research whose results are presented in this article was to choose the optimal system of exchange rate for the Republic of Croatia, of course before its accession to EU. The analyzed exchange rate systems here range from free-floating exchange rate to system without domestic currency in circulation. Naturally, the classification of International Monetary Fond is included in it. After that, the comparison of basic economic advantages and disadvantages of the fixed exchan...

  19. Realities of and perspectives for languages in the globalised world: Can language teaching survive the inadequacies of policies implemented today at Leeds Beckett University?

    Directory of Open Access Journals (Sweden)

    Saadia Gamir

    2017-06-01

    Full Text Available Various newspaper articles report that British ministers, university representatives, exam chiefs and business bodies agree that foreign languages skills in primary, secondary and tertiary UK education are in crisis. Lower funding and policy changes have caused language skills deficiencies felt gravely in the business sectors. Funding and support initiatives pledged by policy makers appear to be election-driven, barely outliving newly elected governments. Others blame secondary school language curriculum for failing to inspire students to take up a language when they reach 13 or 14. Others still argue that severe A-level examinations marking deters students from taking up a foreign language at 6th form level, producing fewer prospective language learners for university departments. Community languages are also undervalued as small-entry languages could soon be axed from GCSE and A-level examinations. In a world increasingly interconnected, it is essential the importance of language learning be reinstated in all our educational institutions. This paper reviews two decades of the conditions of language provision in the UK in general, with an emphasis on Leeds Beckett University. It also attempts to answer two questions emerging form the author’s personal teaching experience and reflections: What are the realities and challenges language teaching faces at Leeds Beckett University? And, how may we support language learners in fulfilling their ambition to acquire the required skills to communicate effectively in this globalised world?

  20. Establishing daily quality control (QC) in screen-film mammography using leeds tor (max) phantom at the breast imaging unit of USTH-Benavides Cancer Institute

    Science.gov (United States)

    Acaba, K. J. C.; Cinco, L. D.; Melchor, J. N.

    2016-03-01

    Daily QC tests performed on screen film mammography (SFM) equipment are essential to ensure that both SFM unit and film processor are working in a consistent manner. The Breast Imaging Unit of USTH-Benavides Cancer Institute has been conducting QC following the test protocols in the IAEA Human Health Series No.2 manual. However, the availability of Leeds breast phantom (CRP E13039) in the facility made the task easier. Instead of carrying out separate tests on AEC constancy and light sensitometry, only one exposure of the phantom is done to accomplish the two tests. It was observed that measurements made on mAs output and optical densities (ODs) using the Leeds TOR (MAX) phantom are comparable with that obtained from the usual conduct of tests, taking into account the attenuation characteristic of the phantom. Image quality parameters such as low contrast and high contrast details were also evaluated from the phantom image. The authors recognize the usefulness of the phantom in determining technical factors that will help improve detection of smallest pathological details on breast images. The phantom is also convenient for daily QC monitoring and economical since less number of films is expended.

  1. Nonequilibrium Contribution to the Rate of Reaction. III. Isothermal Multicomponent Systems

    Science.gov (United States)

    Shizgal, B.; Karplus, M.

    1970-10-01

    The nonequilibrium contribution to the reaction rate of an isothermal multicomponent system is obtained by solution of the appropriate Chapman-Enskog equation; the system is composed of reactive species in contact with a heat bath of inert atoms M.

  2. Confidence Intervals Verification for Simulated Error Rate Performance of Wireless Communication System

    KAUST Repository

    Smadi, Mahmoud A.; Ghaeb, Jasim A.; Jazzar, Saleh; Saraereh, Omar A.

    2012-01-01

    In this paper, we derived an efficient simulation method to evaluate the error rate of wireless communication system. Coherent binary phase-shift keying system is considered with imperfect channel phase recovery. The results presented demonstrate

  3. 76 FR 9694 - Prevailing Rate Systems; Redefinition of the Northeastern Arizona and Colorado Appropriated Fund...

    Science.gov (United States)

    2011-02-22

    ... 3206-AM33 Prevailing Rate Systems; Redefinition of the Northeastern Arizona and Colorado Appropriated... changes are based on recent consensus recommendations of the Federal Prevailing Rate Advisory Committee to... Northeastern Arizona wage area. The Federal Prevailing Rate Advisory Committee (FPRAC), the national labor...

  4. 76 FR 70321 - Prevailing Rate Systems; Redefinition of the Northern Mississippi and Memphis, TN, Appropriated...

    Science.gov (United States)

    2011-11-14

    ... OFFICE OF PERSONNEL MANAGEMENT 5 CFR Part 532 RIN 3206-AM37 Prevailing Rate Systems; Redefinition... on a consensus recommendation of the Federal Prevailing Rate Advisory Committee (FPRAC) to best match... which OPM received no comments. The Federal Prevailing Rate Advisory Committee (FPRAC), the national...

  5. 75 FR 58339 - Prevailing Rate Systems; Redefinition of the Shreveport, LA; Texarkana, TX; Milwaukee, WI; and...

    Science.gov (United States)

    2010-09-24

    ... 3206-AM28 Prevailing Rate Systems; Redefinition of the Shreveport, LA; Texarkana, TX; Milwaukee, WI... area. These changes are based on recent consensus recommendations of the Federal Prevailing Rate... below. The Federal Prevailing Rate Advisory Committee (FPRAC), the national labor-management committee...

  6. 76 FR 31885 - Prevailing Rate Systems; Redefinition of the Northern Mississippi and Memphis, TN, Appropriated...

    Science.gov (United States)

    2011-06-02

    ... OFFICE OF PERSONNEL MANAGEMENT 5 CFR Part 532 RIN 3206-AM37 Prevailing Rate Systems; Redefinition... Prevailing Rate Advisory Committee (FPRAC) to best match the county proposed for redefinition to a nearby FWS... Memphis wage area. The Federal Prevailing Rate Advisory Committee (FPRAC), the national labor-management...

  7. ATLAS trigger operations: Monitoring with “Xmon” rate prediction system

    CERN Document Server

    Aukerman, Andrew Todd; The ATLAS collaboration

    2017-01-01

    We present the operations and online monitoring with the “Xmon” rate prediction system for the trigger system at the ATLAS Experiment. A two-level trigger system reduces the LHC’s bunch-crossing rate, 40 MHz at design capacity, to an average recording rate of about 1 kHz, while maintaining a high efficiency of selecting events of interest. The Xmon system uses the luminosity value to predict trigger rates that are, in turn, compared with incoming rates. The predictions rely on past runs to parameterize the luminosity dependency of the event rate for a trigger algorithm. Some examples are given to illustrate the performance of the tool during recent operations.

  8. Window Energy Rating System and Calculation of Energy Performance of Windows

    DEFF Research Database (Denmark)

    Laustsen, Jacob Birck; Svendsen, Svend

    The goal of reducing the energy consumption in buildings is the background for the introduction of an energy rating system of fenestration products in Denmark. The energy rating system requires that producers declare, among other things, the heat loss coefficient, U, and the total solar energy...... development, e.g. when the resulting effects of a reduced frame area are evaluated....

  9. 78 FR 60181 - Prevailing Rate Systems; Redefinition of the Clayton-Cobb-Fulton, Georgia, Nonappropriated Fund...

    Science.gov (United States)

    2013-10-01

    ... OFFICE OF PERSONNEL MANAGEMENT 5 CFR Part 532 RIN 3206-AM84 Prevailing Rate Systems; Redefinition of the Clayton-Cobb-Fulton, Georgia, Nonappropriated Fund Federal Wage System Wage Area AGENCY: U.S... Counties). The Federal Prevailing Rate Advisory Committee, the national labor-management committee...

  10. The sustainability of the pay-as-you-go system with falling birth rates

    NARCIS (Netherlands)

    van Praag, B.M.S.; Cardoso, P.

    2002-01-01

    A model is presented that explains the mix between funded and unfunded pension systems. It turns out that total pension and the relative shares of the two systems may be explained and are determined by the population growth rate, technological growth, the time-preference discount rate, the relative

  11. 76 FR 32085 - Medicare Program; Inpatient Psychiatric Facilities Prospective Payment System-Update for Rate...

    Science.gov (United States)

    2011-06-03

    ..., ``Inpatient Psychiatric Facilities Prospective Payment System--Update for Rate Year Beginning July 1, 2011 (RY... [CMS-1346-CN] RIN 0938-AQ23 Medicare Program; Inpatient Psychiatric Facilities Prospective Payment System--Update for Rate Year Beginning July 1, 2011 (RY 2012); Correction AGENCY: Centers for Medicare...

  12. Choice of optimal exchange rate system For the Republic of Croatia

    Directory of Open Access Journals (Sweden)

    Dražen Koški

    2008-12-01

    Full Text Available The aim of research whose results are presented in this article was to choose the optimal system of exchange rate for the Republic of Croatia, of course before its accession to EU. The analyzed exchange rate systems here range from free-floating exchange rate to system without domestic currency in circulation. Naturally, the classification of International Monetary Fond is included in it. After that, the comparison of basic economic advantages and disadvantages of the fixed exchange rate in relation to floating exchange rate were carried out. Although the question is about the extreme systems, disregarding the system without domestic currency in circulation, their comparison makes possible completely satisfactory basis for the right conclusions on the choice of optimal exchange rate system for the Republic of Croatia. Considering its economic particularities, the system of managed-floating exchange rate without proclaimed exchange direction in advance is certainly optimal for the Republic of Croatia. Namely, within the framework of this system the limited floating exchange rates decrease the foreign exchange risk allowing to monetary authorities, at least partly, the independent monetary policy

  13. User Participation and Honesty in Online Rating Systems: What a Social Network Can Do

    OpenAIRE

    Davoust, Alan; Esfandiari, Babak

    2016-01-01

    An important problem with online communities in general, and online rating systems in particular, is uncooperative behavior: lack of user participation, dishonest contributions. This may be due to an incentive structure akin to a Prisoners' Dilemma (PD). We show that introducing an explicit social network to PD games fosters cooperative behavior, and use this insight to design a new aggregation technique for online rating systems. Using a dataset of ratings from Yelp, we show that our aggrega...

  14. STAF: A Powerful and Sophisticated CAI System.

    Science.gov (United States)

    Loach, Ken

    1982-01-01

    Describes the STAF (Science Teacher's Authoring Facility) computer-assisted instruction system developed at Leeds University (England), focusing on STAF language and major program features. Although programs for the system emphasize physical chemistry and organic spectroscopy, the system and language are general purpose and can be used in any…

  15. Effect of Room Ventilation Rates in Rodent Rooms with Direct-Exhaust IVC Systems.

    Science.gov (United States)

    Geertsema, Roger S; Lindsell, Claire E

    2015-09-01

    When IVC are directly exhausted from a rodent housing room, the air quality of the room can become independent of the intracage air quality and may reduce the need for high room ventilation rates. This study assessed the effect of decreasing the ventilation rate in rodent rooms using direct-exhaust IVC systems. The study was conducted over 16 wk and compared conditions in 8 rodent rooms that had ventilation rates of 5 to 6 air changes per hour (ACH) with those in rooms at 10 to 12 ACH. At the low ventilation rate, rooms had higher CO₂ concentrations, higher dew point temperature, and lower particulate levels and spent a greater percentage of time above the temperature set point than did rooms at the high rate. The levels of allergens and endotoxins in room air were the same regardless of the ventilation rate. Differences seen in parameters within cages at the 2 ventilation rates were operationally irrelevant. We detected no total volatile organic compounds in the room that were attributable to ammonia, regardless of the ventilation rate. Clearing the air of ethanol after a spill took longer at the low compared with high rate. However, ethanol clearance was faster at the low rate when the demand-control system was activated than at the high ventilation rate alone. Air quality in the room and in the cages were acceptable with room ventilation rates of 5 to 6 ACH in rodent rooms that use direct-exhaust IVC systems.

  16. Heart rate variability in patients with systemic lupus erythematosus: a systematic review and methodological considerations.

    Science.gov (United States)

    Matusik, P S; Matusik, P T; Stein, P K

    2018-07-01

    Aim The aim of this review was to summarize current knowledge about the scientific findings and potential clinical utility of heart rate variability measures in patients with systemic lupus erythematosus. Methods PubMed, Embase and Scopus databases were searched for the terms associated with systemic lupus erythematosus and heart rate variability, including controlled vocabulary, when appropriate. Articles published in English and available in full text were considered. Finally, 11 publications were selected, according to the systematic review protocol and were analyzed. Results In general, heart rate variability, measured in the time and frequency domains, was reported to be decreased in patients with systemic lupus erythematosus compared with controls. In some systemic lupus erythematosus studies, heart rate variability was found to correlate with inflammatory markers and albumin levels. A novel heart rate variability measure, heart rate turbulence onset, was shown to be increased, while heart rate turbulence slope was decreased in systemic lupus erythematosus patients. Reports of associations of changes in heart rate variability parameters with increasing systemic lupus erythematosus activity were inconsistent, showing decreasing heart rate variability or no relationship. However, the low/high frequency ratio was, in some studies, reported to increase with increasing disease activity or to be inversely correlated with albumin levels. Conclusions Patients with systemic lupus erythematosus have abnormal heart rate variability, which reflects cardiac autonomic dysfunction and may be related to inflammatory cytokines but not necessarily to disease activity. Thus measurement of heart rate variability could be a useful clinical tool for monitoring autonomic dysfunction in systemic lupus erythematosus, and may potentially provide prognostic information.

  17. A Compound Detection System Based on Ultrasonic Flow Rate and Concentration

    Directory of Open Access Journals (Sweden)

    Qing-Hui WANG

    2014-02-01

    Full Text Available This paper proposes a new detection system for monitoring gas concentration and flow rate. Velocity difference of ultrasonic wave in bi-directional propagation in measured gas is recorded and utilized for computing the online gas concentration and flow rate. Meanwhile, the temperature compensation, return signal processing and error analysis algorithms are applied to improve the accuracy. The experimental results show that, compared with the single sensor measurement of gas flow rate or concentration, the proposed detection system with lower cost and higher accuracy can be applied in the occasion which needs simultaneous monitoring of gas concentration and flow rate.

  18. Development of linear flow rate control system for eccentric butter-fly valve

    International Nuclear Information System (INIS)

    Kwak, K. K.; Cho, S. W.; Park, J. S.; Cho, J. H.; Song, I. T.; Kim, J. G.; Kwon, S. J.; Kim, I. J.; Park, W. K.

    1999-12-01

    Butter-fly valves are advantageous over gate, globe, plug, and ball valves in a variety of installations, particularly in the large sizes. The purpose of this project development of linear flow rate control system for eccentric butter-fly valve (intelligent butter-fly valve system). The intelligent butter-fly valve system consist of a valve body, micro controller. The micro controller consist of torque control system, pressure censor, worm and worm gear and communication line etc. The characteristics of intelligent butter-fly valve system as follows: Linear flow rate control function. Digital remote control function. guard function. Self-checking function. (author)

  19. Embodied energy of building materials and green building rating systems : a case study for industrial halls

    NARCIS (Netherlands)

    Lee, B.; Trcka, M.; Hensen, J.L.M.

    2011-01-01

    Green building rating (GBR) systems are developed to provide independent assessment standards that evaluate in a few categories about the performance and sustainability of buildings. However, same category might weight differently in each of the GBR systems. A particular system might favor certain

  20. 78 FR 71036 - Pipeline Safety: Random Drug Testing Rate; Contractor Management Information System Reporting...

    Science.gov (United States)

    2013-11-27

    ... PHMSA-2013-0248] Pipeline Safety: Random Drug Testing Rate; Contractor Management Information System Reporting; and Obtaining Drug and Alcohol Management Information System Sign-In Information AGENCY: Pipeline... Management Information System (MIS) Data; and New Method for Operators to Obtain User Name and Password for...

  1. Interplay between spontaneous decay rates and Lamb shifts in open photonic systems

    Science.gov (United States)

    Lassalle, Emmanuel; Bonod, Nicolas; Durt, Thomas; Stout, Brian

    2018-05-01

    In this letter, we describe the modified decay rate and photonic Lamb (frequency) shift of quantum emitters in terms of the resonant states of a neighboring photonic resonator. This description illustrates a fundamental distinction in the behaviors of closed (conservative) and open (dissipative) systems: the Lamb shift is bounded by the emission linewidth in closed systems while it overcomes this limit in open systems.

  2. A system for rating the stability and strength of medical evidence

    Directory of Open Access Journals (Sweden)

    Reston James T

    2006-10-01

    Full Text Available Abstract Background Methods for describing one's confidence in the available evidence are useful for end-users of evidence reviews. Analysts inevitably make judgments about the quality, quantity consistency, robustness, and magnitude of effects observed in the studies identified. The subjectivity of these judgments in several areas underscores the need for transparency in judgments. Discussion This paper introduces a new system for rating medical evidence. The system requires explicit judgments and provides explicit rules for balancing these judgments. Unlike other systems for rating the strength of evidence, our system draws a distinction between two types of conclusions: quantitative and qualitative. A quantitative conclusion addresses the question, "How well does it work?", whereas a qualitative conclusion addresses the question, "Does it work?" In our system, quantitative conclusions are tied to stability ratings, and qualitative conclusions are tied to strength ratings. Our system emphasizes extensive a priori criteria for judgments to reduce the potential for bias. Further, the system makes explicit the impact of heterogeneity testing, meta-analysis, and sensitivity analyses on evidence ratings. This article provides details of our system, including graphical depictions of how the numerous judgments that an analyst makes can be combined. We also describe two worked examples of how the system can be applied to both interventional and diagnostic technologies. Summary Although explicit judgments and formal combination rules are two important steps on the path to a comprehensive system for rating medical evidence, many additional steps must also be taken. Foremost among these are the distinction between quantitative and qualitative conclusions, an extensive set of a priori criteria for making judgments, and the direct impact of analytic results on evidence ratings. These attributes form the basis for a logically consistent system that can

  3. On the hazard rate process for imperfectly monitored multi-unit systems

    International Nuclear Information System (INIS)

    Barros, A.; Berenguer, C.; Grall, A.

    2005-01-01

    The aim of this paper is to present a stochastic model to characterize the failure distribution of multi-unit systems when the current units state is imperfectly monitored. The definition of the hazard rate process existing with perfect monitoring is extended to the realistic case where the units failure time are not always detected (non-detection events). The so defined observed hazard rate process gives a better representation of the system behavior than the classical failure rate calculated without any information on the units state and than the hazard rate process based on perfect monitoring information. The quality of this representation is, however, conditioned by the monotony property of the process. This problem is mainly discussed and illustrated on a practical example (two parallel units). The results obtained motivate the use of the observed hazard rate process to characterize the stochastic behavior of the multi-unit systems and to optimize for example preventive maintenance policies

  4. On the hazard rate process for imperfectly monitored multi-unit systems

    Energy Technology Data Exchange (ETDEWEB)

    Barros, A. [Institut des Sciences et Techonologies de l' Information de Troyes (ISTIT-CNRS), Equipe de Modelisation et Surete des Systemes, Universite de Technologie de Troyes (UTT), 12, rue Marie Curie, BP2060, 10010 Troyes cedex (France)]. E-mail: anne.barros@utt.fr; Berenguer, C. [Institut des Sciences et Techonologies de l' Information de Troyes (ISTIT-CNRS), Equipe de Modelisation et Surete des Systemes, Universite de Technologie de Troyes (UTT), 12, rue Marie Curie, BP2060, 10010 Troyes cedex (France); Grall, A. [Institut des Sciences et Techonologies de l' Information de Troyes (ISTIT-CNRS), Equipe de Modelisation et Surete des Systemes, Universite de Technologie de Troyes (UTT), 12, rue Marie Curie, BP2060, 10010 Troyes cedex (France)

    2005-12-01

    The aim of this paper is to present a stochastic model to characterize the failure distribution of multi-unit systems when the current units state is imperfectly monitored. The definition of the hazard rate process existing with perfect monitoring is extended to the realistic case where the units failure time are not always detected (non-detection events). The so defined observed hazard rate process gives a better representation of the system behavior than the classical failure rate calculated without any information on the units state and than the hazard rate process based on perfect monitoring information. The quality of this representation is, however, conditioned by the monotony property of the process. This problem is mainly discussed and illustrated on a practical example (two parallel units). The results obtained motivate the use of the observed hazard rate process to characterize the stochastic behavior of the multi-unit systems and to optimize for example preventive maintenance policies.

  5. A Compound Detection System Based on Ultrasonic Flow Rate and Concentration

    OpenAIRE

    Qing-Hui WANG; Fang MU; Li-Feng WEI

    2014-01-01

    This paper proposes a new detection system for monitoring gas concentration and flow rate. Velocity difference of ultrasonic wave in bi-directional propagation in measured gas is recorded and utilized for computing the online gas concentration and flow rate. Meanwhile, the temperature compensation, return signal processing and error analysis algorithms are applied to improve the accuracy. The experimental results show that, compared with the single sensor measurement of gas flow rate or conce...

  6. AUTOMATED SYSTEM OF DATA PROCESSING WITH THE IMPLEMENTATION OF RATING TECHNOLOGY OF TEACHING

    Directory of Open Access Journals (Sweden)

    О. И. Дзювина

    2014-01-01

    Full Text Available Rating technology of teaching enables independent and individual work of students, increase their motivation.Purpose: to increase the efficiency of data processing with the implementation of rating technology of teaching.Method: analysis, synthesis,experiment.Results. Developed an automated data processing system for the implementation of rating technology of teaching.Practical implication. Education.Purchase on Elibrary.ru > Buy now

  7. The Impact of Retail Rate Structures on the Economics of Commercial Photovoltaic Systems in California

    OpenAIRE

    Mills, Andrew

    2009-01-01

    This article examines the impact of retail electricity rate design on the economic value of grid-connected photovoltaic (PV) systems, focusing on commercial customers in California. Using 15-min interval building load and PV production data from a sample of 24 actual commercial PV installations, we compare the value of the bill savings across 20 commercial-customer retail electricity rates currently offered in the state. Across all combinations of customers and rates, we find that the annual ...

  8. RCSLK9: reactor coolant system leak rate determination for PWRs. User's guide

    International Nuclear Information System (INIS)

    Kirkpatrick, D.C.; Woodruff, R.W.; Holland, R.A.

    1984-12-01

    RCSLK9 is a computer program that was developed to analyze the leak tightness of the primary cooling system for any pressurized water reactor. From system conditions, water levels in tanks, and certain system design parameters, RCSLK9 calculates the loss of water from the cooling system and the increase of water in the leakage collection system during an arbitrary time interval. The program determines the system leak rates and displays or prints a report of the results. For initial application of the program at a reactor, RCSLK9 creates a file of system parameters and stores it for future use. RCSLK9 is written for use on the IBM PC

  9. Regulation and drive system for high rep-rate magnetic-pulse compressors

    International Nuclear Information System (INIS)

    Birx, D.L.; Cook, E.G.; Hawkins, S.; Meyers, A.; Reginato, L.L.; Schmidt, J.A.; Smith, M.W.

    1982-01-01

    The essentially unlimited rep-rate capability of non-linear magnetic systems has imposed strict requirements on the drive system which initiates the pulse compression. An order of magnitude increase in the rep-rates achieved by the Advanced Test Accelerator (ATA) gas blown system is not difficult to achieve in the magnetic compressor. The added requirement of having a high degree of regulation at the higher rep-rates places strict requirements on the triggerable switch for charging and de-Queing. A novel feedback technique which applies the proper bias to a magnetic core by comparing a reference voltage to the charging voltage eases considerably the regulation required to achieve low jitter in magnetic compression. The performance of the high rep-rate charging and regulation systems will be described in the following pages

  10. Do illness rating systems predict discharge location, length of stay, and cost after total hip arthroplasty?

    Directory of Open Access Journals (Sweden)

    Sarah E. Rudasill, BA

    2018-06-01

    Conclusions: These findings suggest that although ASA classifications predict discharge location and SOI scores predict length of stay and total costs, other factors beyond illness rating systems remain stronger predictors of discharge for THA patients.

  11. Results on stabilization of nonlinear systems under finite data-rate constraints

    NARCIS (Netherlands)

    Persis, Claudio De

    2004-01-01

    We discuss in this paper a result concerning the stabilization problem of nonlinear systems under data-rate constraints using output feedback. To put the result in a broader context, we shall first review a number of recent contributions on the stabilization problem under data-rate constraints when

  12. Electronic circuit SG-6 type for electric differential manometer in the flow rate measuring system

    Energy Technology Data Exchange (ETDEWEB)

    Glowacki, S W; Pytel, K; Beldzikowski, W

    1978-01-01

    A system measuring the flow rate of a liquid or gas employing a ruft and a differential manometer needs the square rooting circuit providing the linearity of the output signal to the measured flow rate ratio. The paper describes the electronic circuit developed for this purpose.

  13. Initial Progress Rates as Related to Performance in a Personalized System of Instruction

    Science.gov (United States)

    Henneberry, John K.

    1976-01-01

    Discusses research which explored the hypothesis that students who are fast starters in a personalized system of instruction psychology course would perform better and maintain faster course progress rates than slow starters. Findings indicate that students' starting pace is predictive of course performance and subsequent progress rates.…

  14. Measurement of semiochemical release rates with a dedicated environmental control system

    Science.gov (United States)

    Heping Zhu; Harold W. Thistle; Christopher M. Ranger; Hongping Zhou; Brian L. Strom

    2015-01-01

    Insect semiochemical dispensers are commonly deployed under variable environmental conditions over a specified period. Predictions of their longevity are hampered by a lack of methods to accurately monitor and predict how primary variables affect semiochemical release rate. A system was constructed to precisely determine semiochemical release rates under...

  15. iHeartrate: a heart rate controlled in-flight music recommendation system

    NARCIS (Netherlands)

    Liu, H.; Hu, J.; Rauterberg, G.W.M.; Spink, A.J.; Grieco, O.E.; Krips, L.W.S.; Loijens, L.P.J.J.; Noldus, xx; Zimmerman, P.H.

    2010-01-01

    Travel by air, especially long distance, the enclosed environment of the aircraft cabin causes discomfort and even stress to flight passengers. In this paper, we present a new heart rate controlled music recommendation system. Heart rate is used as a stress indicator. If the user is stressed and

  16. 47 CFR 76.1504 - Rates, terms and conditions for carriage on open video systems.

    Science.gov (United States)

    2010-10-01

    ....1504 Rates, terms and conditions for carriage on open video systems. (a) Reasonable rate principle. An... operator will bear the burden of proof to demonstrate, using the principles set forth below, that the...; (2) Packaging, including marketing and other fees; (3) Talent fees; and (4) A reasonable overhead...

  17. Learning by Heart: Students Use Heart Rate Patterns To Identify Nervous System Imbalances.

    Science.gov (United States)

    Ackerly, Spafford C.

    2001-01-01

    Introduces a science unit on heart rate variability (HVR) patterns. Uses spectral analysis to determine the effects of environmental stimulants such as music and emotional stress on heart rate. Observes relaxation techniques and their effects on the autonomous nervous system. (Contains 12 references.) (YDS)

  18. Media rating systems: do they work? Shop floor compliance with age restrictions in the Netherlands

    NARCIS (Netherlands)

    Gosselt, Jordi Franciscus; van Hoof, Joris Jasper; de Jong, Menno D.T.

    2012-01-01

    Media rating systems have been introduced in many countries to protect minors from being exposed to harmful media content. This study examines whether retailers comply with the guidelines of media ratings in the Netherlands. In a mystery shopping study, minors tried to buy or rent media products for

  19. The principle of an NRF rating system for the humanities and social ...

    African Journals Online (AJOL)

    The National Research Foundation (NRF) is proposing to introduce a ratings system for the humanities and social sciences comparable to that which pertains in the natural sciences. The article welcomes this development, and argues for full and open consultation with the research community regarding appropriate ratings ...

  20. Library Automation Alternatives in 1996 and User Satisfaction Ratings of Library Users by Operating System.

    Science.gov (United States)

    Cibbarelli, Pamela

    1996-01-01

    Examines library automation product introductions and conversions to new operating systems. Compares user satisfaction ratings of the following library software packages: DOS/Windows, UNIX, Macintosh, and DEC VAX/VMS. Software is rated according to documentation, service/support, training, product reliability, product capabilities, ease of use,…

  1. Demo : an embedded vision system for high frame rate visual servoing

    NARCIS (Netherlands)

    Ye, Z.; He, Y.; Pieters, R.S.; Mesman, B.; Corporaal, H.; Jonker, P.P.

    2011-01-01

    The frame rate of commercial off-the-shelf industrial cameras is breaking the threshold of 1000 frames-per-second, the sample rate required in high performance motion control systems. On the one hand, it enables computer vision as a cost-effective feedback source; On the other hand, it imposes

  2. Nursing home 5-star rating system exacerbates disparities in quality, by payer source.

    Science.gov (United States)

    Konetzka, R Tamara; Grabowski, David C; Perraillon, Marcelo Coca; Werner, Rachel M

    2015-05-01

    Market-based reforms in health care, such as public reporting of quality, may inadvertently exacerbate disparities. We examined how the Centers for Medicare and Medicare Services' five-star rating system for nursing homes has affected residents who are dually enrolled in Medicare and Medicaid ("dual eligibles"), a particularly vulnerable and disadvantaged population. Specifically, we assessed the extent to which dual eligibles and non-dual eligibles avoided the lowest-rated nursing homes and chose the highest-rated homes once the five-star rating system began, in late 2008. We found that both populations resided in better-quality homes over time but that by 2010 the increased likelihood of choosing the highest-rated homes was substantially smaller for dual eligibles than for non-dual eligibles. Thus, the gap in quality, as measured by a nursing home's star rating, grew over time. Furthermore, we found that the benefit of the five-star system to dual eligibles was largely due to providers' improving their ratings, not to consumers' choosing different providers. We present evidence suggesting that supply constraints play a role in limiting dual eligibles' responses to quality ratings, since high-quality providers tend to be located close to relatively affluent areas. Increases in Medicaid payment rates for nursing home services may be the only long-term solution. Project HOPE—The People-to-People Health Foundation, Inc.

  3. Increasing the bit rate in OCDMA systems using pulse position modulation techniques.

    Science.gov (United States)

    Arbab, Vahid R; Saghari, Poorya; Haghi, Mahta; Ebrahimi, Paniz; Willner, Alan E

    2007-09-17

    We have experimentally demonstrated two novel pulse position modulation techniques, namely Double Pulse Position Modulation (2-PPM) and Differential Pulse Position Modulation (DPPM) in Time-Wavelength OCDMA systems that will operate at a higher bit rate compared to traditional OOK-OCDMA systems with the same bandwidth. With 2-PPM technique, the number of active users will be more than DPPM while their bit rate is almost the same. Both techniques provide variable quality of service in OCDMA networks.

  4. Fair premium rate of the deposit insurance system based on banks' creditworthiness

    OpenAIRE

    Yoshino, Naoyuki; Taghizadeh-Hesary, Farhad; Nili, Farhad

    2017-01-01

    Purpose: Deposit insurance is a key element in modern banking, as it guarantees the financial safety of deposits at depository financial institutions. It is necessary to have at least a dual fair premium rate system based on the creditworthiness of financial institutions, as considering a singular premium system for all banks will have a moral hazard. In this paper, we develop a theoretical as well as an empirical model for calculating dual fair premium rates. Design/methodology/approach: Our...

  5. Experience with Floating Interbank Exchange Rate Systems in Five Developing Economies

    OpenAIRE

    Vicente Galbis

    1993-01-01

    This paper reviews the experience with floating interbank exchange rate systems in five developing countries--The Gambia, Guyana, Jamaica, Nigeria and Sri Lanka--and draws some conclusions about the stability and efficiency of these systems. The experience of these countries illustrates both the difficulties and the advantages of interbank exchange rate markets. The main conclusion is that these markets can operate relatively well with a minimum banking infrastructure, provided that the autho...

  6. Financial Prospect to The Application of High Rate Water Treatment Plant System

    Directory of Open Access Journals (Sweden)

    Mohajit Mohajit

    2015-10-01

    Full Text Available The High Rate Water Treatment Plant (HR-WTP system, which is inexpensive, effective and efficient, has been developed to reduce the common operational problems, and also as an alternative for the development of water treatment plant systems capacity in Indonesia.Implementation of HR-WTP system in up-rating of the Dekeng-WTP system at PDAM Kota Bogor proved successful in increasing the plant capacity from its original of 500 Lps to more than 1200 Lps. The performance of the WTP system was also significantly improved from poor performance to very good performance.The investment cost for up-rating proved competitive when compared to alternatively constructing a new WTP system with an equivalent capacity and performance. Application of HR-WTP systems for the development of WTP system in Indonesia, i.e. rehabilitation, up-grading, and up-rating, as well as construction of a new WTP system, is expected to bring technical, financial, and economic benefits. This new approach might be an innovative solution to the challenge of Millennium Development Goals in Water Supply Sector in Indonesia, where an additional capacity of ca 150,000 Lps should be developed within a 15 years period with an estimated budget of US $1.5 billions. This budget might be reduced to less than 50% through the application of the HR-WTP system.

  7. Photovoltaic systems for Malaysian islands: Effects of interest rates, diesel prices and load sizes

    International Nuclear Information System (INIS)

    Lau, K.Y.; Tan, C.W.; Yatim, A.H.M.

    2015-01-01

    Standalone diesel systems have been widely used on Malaysian islands due to the isolated locations of the islands. Nevertheless, the high diesel prices and the high cost of transporting diesel to islands cause the use of standalone diesel systems to be uneconomical. This study analyzes the feasibility of implementing PV (photovoltaic) systems as alternatives to standalone diesel systems by considering the effects of annual real interest rates, diesel prices and load sizes, using the HOMER (hybrid optimization of multiple energy resources) software. The results indicate that, at the ordinary diesel price of $ 0.61/L, low interest rates (0–3%) are desirable for the implementation of hybrid PV/diesel with battery systems over standalone diesel systems, regardless of the load sizes. Although different load sizes may affect the decisions on the implementation of PV systems at higher interest rates (6–9%), these effects become less pronounced as the price of diesel increases to $ 1.22/L or higher. Also, under high diesel prices, the choice of optimal system configurations obtained for small load sizes should be applicable for larger load sizes, albeit with different component ratings. Although the current study is intended for Malaysian islands, the findings can be generalized for other places with similar solar radiation levels. - Highlights: • Photovoltaic systems for Malaysian islands have been analyzed using HOMER. • Interest rates, diesel prices and load sizes affect optimal system configurations. • Effects of interest rates and load sizes reduce with increasing diesel prices. • Photovoltaic systems' implementation is feasible at high diesel prices. • The findings can be generalized for places with similar solar radiation levels

  8. Development of a new energy efficiency rating system for existing residential buildings

    International Nuclear Information System (INIS)

    Koo, Choongwan; Hong, Taehoon; Lee, Minhyun; Seon Park, Hyo

    2014-01-01

    Building energy efficiency rating systems have been established worldwide to systematically manage the energy consumption of existing buildings. This study aimed to develop a new energy efficiency rating system for existing residential buildings from two perspectives: (i) establishment of reasonable and fair criteria for the building energy efficiency rating system; and (ii) establishment of comparative incentive and penalty programs to encourage the voluntary participation of all residents in the energy saving campaign. Based on the analysis of the conventional energy efficiency rating system for existing residential buildings, this study was conducted in five steps: (i) data collection and analysis; (ii) correlation analysis between the household size and the CO 2 emission density (i.e., CO 2 emission per unit area); (iii) cluster formation based on results of the correlation analysis using a decision tree; (iv) establishment of a new energy efficiency rating system for existing buildings; and (v) establishment of incentive and penalty programs using advanced case-based reasoning. The proposed system can allow a policymaker to establish a reasonable and fair energy efficiency rating system for existing residential buildings and can encourage the voluntary participation of all residents in the energy saving campaign. - Highlights: • A new energy efficiency rating system for the residential building was developed. • The incentive and penalty programs were established using an advanced CBR model. • The new system was established using reasonable and fair standards. • It allows all residents to voluntarily participate in the energy saving campaign. • It can be applied to any country or sector in the global environment

  9. Development of ultra high speed photographic system using high repetition rate visible laser

    International Nuclear Information System (INIS)

    Lee, Jong Min; Cha, Byung Hun; Kim, Sung Ho; Kim, Jung Bog; Lim, Chang Hwan; Cha, Hyung Ki; Song, Kyu Seok; Lee, Byung Deok; Rhi, Jong Hoon; Baik, Dae Hyun; Han, Jae Min; Rho, Si Pyo; Lee, Byung Cheol; Jeong, Do Yung; Choi, An Seong; Jeong, Chan Ik; Park, Dae Ung; Jeong, Sung Min; Lee, Sang Kil; Kim, Heon Jun; Jang, Rae gak; Jo, Do Hun; Park, Min Young

    1992-12-01

    The goal of this project is to develop and commercialize a high speed photographic system equipped with a high repetition rate visible laser. The developed system provides the characteristics of high time resolution and large number of frames. The system consists of 10 W air cooled CVL or a 30 W water cooled CVL, a rotating drum-type high speed camera with the framing rate of 35,000 fps, and a automatic control device. The system has the performance of 10 nsec time resolution, 35,000 fps framing rate, and 250 picture frames. The high speed photographic systems are widely applied to the fields such as high-efficient engine development, high-speed vibration analysis, shock wave propagation study, flow visualization analysis, weapon development, etc. (Author)

  10. A model for the coupling of failure rates in a redundant system

    International Nuclear Information System (INIS)

    Kleppmann, W.G.; Wutschig, R.

    1986-01-01

    A model is developed which takes into acount the coupling between failure rates or identical components in different redundancies of a safety system, i.e., the fact that the failure rates of identical components subjected to the same operating conditions will scatter less than the failure rates of any two components of the same type. It is shown that with increasing coupling the expectation value and the variance of the distribution of the failure probability of the redundant system increases. A consistent way to incorporate operating experience in a Bayesian framework is developed and the reults are presented. (orig.)

  11. A statistical modeling approach to build expert credit risk rating systems

    DEFF Research Database (Denmark)

    Waagepetersen, Rasmus

    2010-01-01

    This paper presents an efficient method for extracting expert knowledge when building a credit risk rating system. Experts are asked to rate a sample of counterparty cases according to creditworthiness. Next, a statistical model is used to capture the relation between the characteristics...... of a counterparty and the expert rating. For any counterparty the model can identify the rating, which would be agreed upon by the majority of experts. Furthermore, the model can quantify the concurrence among experts. The approach is illustrated by a case study regarding the construction of an application score...

  12. System and method for determining an ammonia generation rate in a three-way catalyst

    Science.gov (United States)

    Sun, Min; Perry, Kevin L; Kim, Chang H

    2014-12-30

    A system according to the principles of the present disclosure includes a rate determination module, a storage level determination module, and an air/fuel ratio control module. The rate determination module determines an ammonia generation rate in a three-way catalyst based on a reaction efficiency and a reactant level. The storage level determination module determines an ammonia storage level in a selective catalytic reduction (SCR) catalyst positioned downstream from the three-way catalyst based on the ammonia generation rate. The air/fuel ratio control module controls an air/fuel ratio of an engine based on the ammonia storage level.

  13. Method and system of simulating nuclear power plant count rate for training purposes

    International Nuclear Information System (INIS)

    Alliston, W.H.; Koenig, R.H.

    1975-01-01

    A method and system are described for the real-time simulation of the dynamic operation of a nuclear power plant in which nuclear flux rate counters are provided for monitoring the rate of nuclear fission of the reactor. The system utilizes apparatus that includes digital computer means for calculating data relating to the rate of nuclear fission of a simulated reactor model, which rate is controlled in accordance with the operation of control panel devices. A digital number from the computer corresponding to the flux rate controls an oscillator driven counter means to produce a pulse after a predetermined count. This pulse controls an oscillator driven polynomial counter to count a random number that controls a third counter in accordance with pulse from the first counter to produce a random fission count for operating the meters. (U.S.)

  14. Nocturnal variations in peripheral blood flow, systemic blood pressure, and heart rate in humans

    DEFF Research Database (Denmark)

    Sindrup, J H; Kastrup, J; Christensen, H

    1991-01-01

    Subcutaneous adipose tissue blood flow rate, together with systemic arterial blood pressure and heart rate under ambulatory conditions, was measured in the lower legs of 15 normal human subjects for 12-20 h. The 133Xe-washout technique, portable CdTe(Cl) detectors, and a portable data storage uni.......0001). The synchronism of the nocturnal subcutaneous hyperemia and the decrease in systemic mean arterial blood pressure point to a common, possibly central nervous or humoral, eliciting mechanism.......Subcutaneous adipose tissue blood flow rate, together with systemic arterial blood pressure and heart rate under ambulatory conditions, was measured in the lower legs of 15 normal human subjects for 12-20 h. The 133Xe-washout technique, portable CdTe(Cl) detectors, and a portable data storage unit...

  15. Tracking Controller for Intrinsic Output Saturated Systems in Presence of Amplitude and Rate Input Saturations

    DEFF Research Database (Denmark)

    Chater, E.; Giri, F.; Guerrero, Josep M.

    2014-01-01

    We consider the problem of controlling plants that are subject to multiple saturation constraints. Especially, we are interested in linear systems whose input is subject to amplitude and rate constraints of saturation type. Furthermore, the considered systems output is also subject to an intrinsi...

  16. Embodied energy of building materials and green building rating systems : a case study for industrial halls

    NARCIS (Netherlands)

    Lee, B.; Trcka, M.; Hensen, J.L.M.

    2010-01-01

    Green Building Rating (GBR) systems are developed to provide independent assessment standards that evaluate in a few categories about the performance and sustainability of buildings. However, same category might weight differently in each of the GBR systems, which are different in objectives. A

  17. A Framework for Control System Design Subject to Average Data-Rate Constraints

    DEFF Research Database (Denmark)

    Silva, Eduardo; Derpich, Milan; Østergaard, Jan

    2011-01-01

    This paper studies discrete-time control systems subject to average data-rate limits. We focus on a situation where a noisy linear system has been designed assuming transparent feedback and, due to implementation constraints, a source-coding scheme (with unity signal transfer function) has to be ...

  18. An OFDM System Using Polyphase Filter and DFT Architecture for Very High Data Rate Applications

    Science.gov (United States)

    Kifle, Muli; Andro, Monty; Vanderaar, Mark J.

    2001-01-01

    This paper presents a conceptual architectural design of a four-channel Orthogonal Frequency Division Multiplexing (OFDM) system with an aggregate information throughput of 622 megabits per second (Mbps). Primary emphasis is placed on the generation and detection of the composite waveform using polyphase filter and Discrete Fourier Transform (DFT) approaches to digitally stack and bandlimit the individual carriers. The four-channel approach enables the implementation of a system that can be both power and bandwidth efficient, yet enough parallelism exists to meet higher data rate goals. It also enables a DC power efficient transmitter that is suitable for on-board satellite systems, and a moderately complex receiver that is suitable for low-cost ground terminals. The major advantage of the system as compared to a single channel system is lower complexity and DC power consumption. This is because the highest sample rate is half that of the single channel system and synchronization can occur at most, depending on the synchronization technique, a quarter of the rate of a single channel system. The major disadvantage is the increased peak-to-average power ratio over the single channel system. Simulation results in a form of bit-error-rate (BER) curves are presented in this paper.

  19. Sustainable systems rating program: Marketing Green'' Building in Austin, Texas

    Energy Technology Data Exchange (ETDEWEB)

    1991-12-01

    Four major resource issues for home construction were identified: water, energy, materials, and waste. A systems flow model was then developed that tracked the resource issues through interactive matrices in the areas of sourcing, processing, using, and disposing or recycling. This model served as the basis for a rating system used in an educational and marketing tool called the Eco-Home Guide.

  20. Experimental investigation on preconditioned rate induced tipping in a thermoacoustic system.

    Science.gov (United States)

    Tony, J; Subarna, S; Syamkumar, K S; Sudha, G; Akshay, S; Gopalakrishnan, E A; Surovyatkina, E; Sujith, R I

    2017-07-14

    Many systems found in nature are susceptible to tipping, where they can shift from one stable dynamical state to another. This shift in dynamics can be unfavorable in systems found in various fields ranging from ecology to finance. Hence, it is important to identify the factors that can lead to tipping in a physical system. Tipping can mainly be brought about by a change in parameter or due to the influence of external fluctuations. Further, the rate at which the parameter is varied also determines the final state that the system attains. Here, we show preconditioned rate induced tipping in experiments and in a theoretical model of a thermoacoustic system. We provide a specific initial condition (preconditioning) and vary the parameter at a rate higher than a critical rate to observe tipping. We find that the critical rate is a function of the initial condition. Our study is highly relevant because the parameters that dictate the asymptotic behavior of many physical systems are temporally dynamic.

  1. Comparing Cultural Differences in Two Quality Measures in Chinese Kindergartens: The Early Childhood Environment Rating Scale-Revised and the Kindergarten Quality Rating System

    Science.gov (United States)

    Hu, Bi Ying

    2015-01-01

    This study examined the degrees of congruence between two early childhood evaluation systems on various quality concepts: the Early Childhood Environment Rating Scale-Revised (ECERS-R) and Zhejiang's Kindergarten Quality Rating System (KQRS). Analysis of variance and post hoc least significant difference tests were employed to show the extent to…

  2. Prediction on corrosion rate of pipe in nuclear power system based on optimized grey theory

    International Nuclear Information System (INIS)

    Chen Yonghong; Zhang Dafa; Chen Dengke; Jiang Wei

    2007-01-01

    For the prediction of corrosion rate of pipe in nuclear power system, the pre- diction error from the grey theory is greater, so a new method, optimized grey theory was presented in the paper. A comparison among predicted results from present and other methods was carried out, and it is seem that optimized grey theory is correct and effective for the prediction of corrosion rate of pipe in nuclear power system, and it provides a fundamental basis for the maintenance of pipe in nuclear power system. (authors)

  3. Human-rating Automated and Robotic Systems - (How HAL Can Work Safely with Astronauts)

    Science.gov (United States)

    Baroff, Lynn; Dischinger, Charlie; Fitts, David

    2009-01-01

    Long duration human space missions, as planned in the Vision for Space Exploration, will not be possible without applying unprecedented levels of automation to support the human endeavors. The automated and robotic systems must carry the load of routine housekeeping for the new generation of explorers, as well as assist their exploration science and engineering work with new precision. Fortunately, the state of automated and robotic systems is sophisticated and sturdy enough to do this work - but the systems themselves have never been human-rated as all other NASA physical systems used in human space flight have. Our intent in this paper is to provide perspective on requirements and architecture for the interfaces and interactions between human beings and the astonishing array of automated systems; and the approach we believe necessary to create human-rated systems and implement them in the space program. We will explain our proposed standard structure for automation and robotic systems, and the process by which we will develop and implement that standard as an addition to NASA s Human Rating requirements. Our work here is based on real experience with both human system and robotic system designs; for surface operations as well as for in-flight monitoring and control; and on the necessities we have discovered for human-systems integration in NASA's Constellation program. We hope this will be an invitation to dialog and to consideration of a new issue facing new generations of explorers and their outfitters.

  4. The impact of retail rate structures on the economics of commercial photovoltaic systems in California

    International Nuclear Information System (INIS)

    Mills, Andrew; Wiser, Ryan; Barbose, Galen; Golove, William

    2008-01-01

    This article examines the impact of retail electricity rate design on the economic value of grid-connected photovoltaic (PV) systems, focusing on commercial customers in California. Using 15-min interval building load and PV production data from a sample of 24 actual commercial PV installations, we compare the value of the bill savings across 20 commercial-customer retail electricity rates currently offered in the state. Across all combinations of customers and rates, we find that the annual bill savings from PV, per kWh generated, ranges from 0.05 to 0.24/kWh. This sizable range in rate-reduction value reflects differences in rate structures, revenue requirements, the size of the PV system relative to building load, and customer load shape. The most significant rate design issue for the value of commercial PV is found to be the percentage of total utility bills recovered through demand charges, though a variety of other factors are also found to be of importance. The value of net metering is found to be substantial, but only when energy from commercial PV systems represents a sizable portion of annual customer load. Though the analysis presented here is specific to California, our general results demonstrate the fundamental importance of retail rate design for the customer-economics of grid-connected, customer-sited PV. (author)

  5. Shilling attack detection for recommender systems based on credibility of group users and rating time series.

    Science.gov (United States)

    Zhou, Wei; Wen, Junhao; Qu, Qiang; Zeng, Jun; Cheng, Tian

    2018-01-01

    Recommender systems are vulnerable to shilling attacks. Forged user-generated content data, such as user ratings and reviews, are used by attackers to manipulate recommendation rankings. Shilling attack detection in recommender systems is of great significance to maintain the fairness and sustainability of recommender systems. The current studies have problems in terms of the poor universality of algorithms, difficulty in selection of user profile attributes, and lack of an optimization mechanism. In this paper, a shilling behaviour detection structure based on abnormal group user findings and rating time series analysis is proposed. This paper adds to the current understanding in the field by studying the credibility evaluation model in-depth based on the rating prediction model to derive proximity-based predictions. A method for detecting suspicious ratings based on suspicious time windows and target item analysis is proposed. Suspicious rating time segments are determined by constructing a time series, and data streams of the rating items are examined and suspicious rating segments are checked. To analyse features of shilling attacks by a group user's credibility, an abnormal group user discovery method based on time series and time window is proposed. Standard testing datasets are used to verify the effect of the proposed method.

  6. Factors influencing the recycling rate under the volume-based waste fee system in South Korea.

    Science.gov (United States)

    Park, Seejeen

    2018-04-01

    Since the early 2000s, the Republic of Korea (South Korea) has maintained its top-rank status for its municipal solid waste (MSW) recycling rate among OECD (Organization for Economic Cooperation and Development) member countries. The volume-based waste fee system (VWF) has been considered to be the major factor contributing to the high recycling performance, and extant research has verified the positive relationship between VWF adoption and the MSW recycling rate. Nevertheless, there exists a gap in the literature, as past research has focused more on testing the positive effects of VWF rather than on investigating the determinants of recycling rates after the adoption of VWF. The current study seeks to address this gap by investigating the various factors that affect recycling rates under the VWF system. More specifically, using data from 16 regions in South Korea over a period of 11 years, this study empirically tests the effects of VWF pricing, the citizen cost burden ratio for the VWF system, and pro-environmental behavior related to VWF on the recycling rate. The findings indicate that economic incentives such as cost savings on VWF plastic bag purchases and reduced burden from paying VWF expenses result in higher recycling rates. The findings also demonstrate that pro-environmental behavior in the VWF context positively affects the recycling rate. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Bit rate maximization for multicast LP-OFDM systems in PLC context

    OpenAIRE

    Maiga , Ali; Baudais , Jean-Yves; Hélard , Jean-François

    2009-01-01

    ISBN: 978-88-900984-8-2.; International audience; In this paper, we propose a new resource allocation algorithm based on linear precoding technique for multicast OFDM systems. Linear precoding technique applied to OFDM systems has already proved its ability to significantly increase the system throughput in a powerline communication (PLC) context. Simulations through PLC channels show that this algorithm outperforms the classical multicast method (up to 7.3% bit rate gain) and gives better pe...

  8. Forage mass and stocking rate of elephant grass pastures managed under agroecological and conventional systems

    OpenAIRE

    Clair Jorge Olivo; Carlos Alberto Agnolin; Priscila Flôres Aguirre; Cláudia Marques de Bem; Tiago Luís da Ros de Araújo; Michelle Schalemberg Diehl; Gilmar Roberto Meinerz

    2014-01-01

    The objective was to evaluate elephant grass (Pennisetum purpureum Schum.) pastures, under the agroecological and conventional systems, as forage mass and stocking rate. In the agroecological system, the elephant grass was established in rows spaced by 3.0 m from each other. During the cool season ryegrass (Lolium multiflorum Lam.) was established between these rows, which allowed the development of spontaneous growth species during the warm season. In the conventional system the elephant gra...

  9. The effect of inflation rate on the cost of medical waste management system

    Science.gov (United States)

    Jolanta Walery, Maria

    2017-11-01

    This paper describes the optimization study aimed to analyse the impact of the parameter describing the inflation rate on the cost of the system and its structure. The study was conducted on the example of the analysis of medical waste management system in north-eastern Poland, in the Podlaskie Province. The scope of operational research carried out under the optimization study was divided into two stages of optimization calculations with assumed technical and economic parameters of the system. In the first stage, the lowest cost of functioning of the analysed system was generated, whereas in the second one the influence of the input parameter of the system, i.e. the inflation rate on the economic efficiency index (E) and the spatial structure of the system was determined. With the assumed inflation rate in the range of 1.00 to 1.12, the highest cost of the system was achieved at the level of PLN 2022.20/t (increase of economic efficiency index E by ca. 27% in comparison with run 1, with inflation rate = 1.12).

  10. Comparing Occupational Health and Safety Management System Programming with Injury Rates in Poultry Production.

    Science.gov (United States)

    Autenrieth, Daniel A; Brazile, William J; Douphrate, David I; Román-Muñiz, Ivette N; Reynolds, Stephen J

    2016-01-01

    Effective methods to reduce work-related injuries and illnesses in animal production agriculture are sorely needed. One approach that may be helpful for agriculture producers is the adoption of occupational health and safety management systems. In this replication study, the authors compared the injury rates on 32 poultry growing operations with the level of occupational health and safety management system programming at each farm. Overall correlations between injury rates and programming level were determined, as were correlations between individual management system subcomponents to ascertain which parts might be the most useful for poultry producers. It was found that, in general, higher levels of occupational health and safety management system programming were associated with lower rates of workplace injuries and illnesses, and that Management Leadership was the system subcomponent with the strongest correlation. The strength and significance of the observed associations were greater on poultry farms with more complete management system assessments. These findings are similar to those from a previous study of the dairy production industry, suggesting that occupational health and safety management systems may hold promise as a comprehensive way for producers to improve occupational health and safety performance. Further research is needed to determine the effectiveness of such systems to reduce farm work injuries and illnesses. These results are timely given the increasing focus on occupational safety and health management systems.

  11. Forage mass and stocking rate of elephant grass pastures managed under agroecological and conventional systems

    Directory of Open Access Journals (Sweden)

    Clair Jorge Olivo

    2014-06-01

    Full Text Available The objective was to evaluate elephant grass (Pennisetum purpureum Schum. pastures, under the agroecological and conventional systems, as forage mass and stocking rate. In the agroecological system, the elephant grass was established in rows spaced by 3.0 m from each other. During the cool season ryegrass (Lolium multiflorum Lam. was established between these rows, which allowed the development of spontaneous growth species during the warm season. In the conventional system the elephant grass was established singularly in rows spaced 1.4 m from each other. Organic and chemical fertilizers were applied at 150 kg of N/ha/year with in the pastures under agroecological and conventional systems, respectively. Lactating Holstein cows which received 5.0 kg/day supplementary concentrate feed were used for evaluation. The experimental design was completely randomized, with two treatments (agroecological and conventional systems two replications (paddocks and independent evaluations (grazing cycles. The pastures were used during the whole year for the agroecological system and for 195 days in the conventional year. The average values of forage mass were 3.5 and 4.2 t/ha and the stocking rates were 2.08 and 3.23 AU/ha for the respective systems. The results suggest that the use of the elephant grass under the agroecological system allows for best distribution of forage and stocking rate to be more uniform throughout the year than the use of elephant grass in conventional system.

  12. Clinical rating systems in elbow research-a systematic review exploring trends and distributions of use.

    Science.gov (United States)

    Evans, Jonathan P; Smith, Chris D; Fine, Nicola F; Porter, Ian; Gangannagaripalli, Jaheeda; Goodwin, Victoria A; Valderas, Jose M

    2018-04-01

    Clinical rating systems are used as outcome measures in clinical trials and attempt to gauge the patient's view of his or her own health. The choice of clinical rating system should be supported by its performance against established quality standards. A search strategy was developed to identify all studies that reported the use of clinical rating systems in the elbow literature. The strategy was run from inception in Medline Embase and CINHAL. Data extraction identified the date of publication, country of data collection, pathology assessed, and the outcome measure used. We identified 980 studies that reported clinical rating system use. Seventy-two separate rating systems were identified. Forty-one percent of studies used ≥2 separate measures. Overall, 54% of studies used the Mayo Elbow Performance Score (MEPS). For arthroplasty, 82% used MEPS, 17% used Disabilities of Arm, Shoulder and Hand (DASH), and 7% used QuickDASH. For trauma, 66.7% used MEPS, 32% used DASH, and 23% used the Morrey Score. For tendinopathy, 31% used DASH, 23% used Patient-Rated Tennis Elbow Evaluation (PRTEE), and 13% used MEPS. Over time, there was an increased proportional use of the MEPS, DASH, QuickDASH, PRTEE, and the Oxford Elbow Score. This study identified a wide choice and usage of clinical rating systems in the elbow literature. Numerous studies reported measures without a history of either a specific pathology or cross-cultural validation. Interpretability and comparison of outcomes is dependent on the unification of outcome measure choice. This was not demonstrated currently. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  13. High-Rate Data-Capture for an Airborne Lidar System

    Science.gov (United States)

    Valett, Susan; Hicks, Edward; Dabney, Philip; Harding, David

    2012-01-01

    A high-rate data system was required to capture the data for an airborne lidar system. A data system was developed that achieved up to 22 million (64-bit) events per second sustained data rate (1408 million bits per second), as well as short bursts (less than 4 s) at higher rates. All hardware used for the system was off the shelf, but carefully selected to achieve these rates. The system was used to capture laser fire, single-photon detection, and GPS data for the Slope Imaging Multi-polarization Photo-counting Lidar (SIMPL). However, the system has applications for other laser altimeter systems (waveform-recording), mass spectroscopy, xray radiometry imaging, high-background- rate ranging lidar, and other similar areas where very high-speed data capture is needed. The data capture software was used for the SIMPL instrument that employs a micropulse, single-photon ranging measurement approach and has 16 data channels. The detected single photons are from two sources those reflected from the target and solar background photons. The instrument is non-gated, so background photons are acquired for a range window of 13 km and can comprise many times the number of target photons. The highest background rate occurs when the atmosphere is clear, the Sun is high, and the target is a highly reflective surface such as snow. Under these conditions, the total data rate for the 16 channels combined is expected to be approximately 22 million events per second. For each photon detection event, the data capture software reads the relative time of receipt, with respect to a one-per-second absolute time pulse from a GPS receiver, from an event timer card with 0.1-ns precision, and records that information to a RAID (Redundant Array of Independent Disks) storage device. The relative time of laser pulse firings must also be read and recorded with the same precision. Each of the four event timer cards handles the throughput from four of the channels. For each detection event, a flag is

  14. Anomalous dependence of population growth on the birth rate in the plant-herbivore system

    International Nuclear Information System (INIS)

    Cui, Xue M.; Han, Seung K.; Chung, Jean S.

    2010-01-01

    We performed a simulation of the two-species plant-herbivore system by using the agent-based NetLogo program and constructed a dynamic model of populations consistent with the simulation results. The dynamic model is a three-dimensional system including the mean energy of the herbivore in addition to two variables denoting the populations of plants and herbivores. A steady-state analysis of the dynamic model shows that the dependence of the herbivore population on the birth and the death rates observed from the agent model is consistent with the prediction of the dynamic model. Especially, the anomalous dependence of the herbivore population on the birth rate, where the population decreases with the birth rate for small death rate, is consistently explained by a phase plane analysis of the dynamic model.

  15. A Low-Cost Time-Hopping Impulse Radio System for High Data Rate Transmission

    Directory of Open Access Journals (Sweden)

    Jinyun Zhang

    2005-03-01

    Full Text Available We present an efficient, low-cost implementation of time-hopping impulse radio that fulfills the spectral mask mandated by the FCC and is suitable for high-data-rate, short-range communications. Key features are (i all-baseband implementation that obviates the need for passband components, (ii symbol-rate (not chip rate sampling, A/D conversion, and digital signal processing, (iii fast acquisition due to novel search algorithms, and (iv spectral shaping that can be adapted to accommodate different spectrum regulations and interference environments. Computer simulations show that this system can provide 110 Mbps at 7–10 m distance, as well as higher data rates at shorter distances under FCC emissions limits. Due to the spreading concept of time-hopping impulse radio, the system can sustain multiple simultaneous users, and can suppress narrowband interference effectively.

  16. THIDA: code system for calculation of the exposure dose rate around a fusion device

    International Nuclear Information System (INIS)

    Iida, Hiromasa; Igarashi, Masahito.

    1978-12-01

    A code system THIDA has been developed for calculation of the exposure dose rates around a fusion device. It consists of the following: one- and two-dimensional discrete ordinate transport codes; induced activity calculation code; activation chain, activation cross section, radionuclide gamma-ray energy/intensity and gamma-ray group constant files; and gamma ray flux to exposure dose rate conversion coefficients. (author)

  17. System and Method for Determining Rate of Rotation Using Brushless DC Motor

    Science.gov (United States)

    Howard, David E. (Inventor); Smith, Dennis A. (Inventor)

    2000-01-01

    A system and method are provided for measuring rate of rotation. A brushless DC motor is rotated and produces a back electromagnetic force (emf) on each winding thereof. Each winding's back-emf is squared. The squared outputs associated with each winding are combined, with the square root being taken of such combination, to produce a DC output proportional only to the rate of rotation of the motor's shaft.

  18. The software and hardware design of a 16 channel online dose rate monitoring system

    International Nuclear Information System (INIS)

    Tang Wenjuan; Yan Yonghong; Yang Shiming; Li Xiaonan; Min Jian

    2011-01-01

    The software and hardware design of a 16 channel online dose rate monitoring system is presented. After being amplified and A/D converted, the output signal of the sensors was sent to a microprocessor through an FPGA, where the low-frequency filter, calculation, temperature compensation and pedestal deduction were accomplished. Such steps corrected the variation of dark current dependent on temperature fluctuations in a effective way, and finally the instantaneous dose rate results with enough precise were obtained. (authors)

  19. Corporate Taxation and Investment: The Case of the Split Rate Corporate Tax System in Macedonia

    Directory of Open Access Journals (Sweden)

    Ilija Gruevski

    2018-12-01

    Full Text Available The majority of experts agree that taxes are distortionary in nature. This is relatively true for all of the different groups of taxes, but for the corporate taxes is exceptionallyobvious. The existence of the corporate tax system can affect the company’s behavior in number of ways and one of the most criticized is the ability for distortion of the choice of the sources of finance. In the following article, we explore the effects from corporate taxation on investment, through the methodological frame of the effective marginal tax rates. The objective is to analyze the investment decision in the case of isolated implementation of corporate taxes which means that the effects from the so-called “double taxation”, induced by the personal taxes are not taken in consideration. We hope to prove that these conditions generate “uneven” distribution of the burden across the projects covered with different sources of finance. Also, we intend to test and explore the properties of some alternative corporate tax systems which are widely known as neutral, such as: the comprehensive business income tax system (CBIT, the imputation corporate tax system (ICT, the full imputation corporate tax system (FICT, the allowance for corporate equity tax system (ACE and the split rate corporate tax system (SRCT. In addition, we support our findings with a practical example: the case study from the implementation of the split rate corporate tax system in Macedonia.

  20. Engineering analysis of mass flow rate for turbine system control and design

    International Nuclear Information System (INIS)

    Yoo, Yong H.; Suh, Kune Y.

    2011-01-01

    Highlights: → A computer code is written to predict the steam mass flow rate through valves. → A test device is built to study the steam flow characteristics in the control valve. → Mass flow based methodology eases the programming and experimental procedures. → The methodology helps express the characteristics of each device of a turbine system. → The results can commercially be used for design and operation of the turbine system. - Abstract: The mass flow rate is determined in the steam turbine system by the area formed between the stem disk and the seat of the control valve. For precise control the steam mass flow rate should be known given the stem lift. However, since the thermal hydraulic characteristics of steam coming from the generator or boiler are changed going through each device, it is hard to accurately predict the steam mass flow rate. Thus, to precisely determine the steam mass flow rate, a methodology and theory are developed in designing the turbine system manufactured for the nuclear and fossil power plants. From the steam generator or boiler to the first bunch of turbine blades, the steam passes by a stop valve, a control valve and the first nozzle, each of which is connected with piping. The corresponding steam mass flow rate can ultimately be computed if the thermal and hydraulic conditions are defined at the stop valve, control valve and pipes. The steam properties at the inlet of each device are changed at its outlet due to geometry. The Compressed Adiabatic Massflow Analysis (CAMA) computer code is written to predict the steam mass flow rate through valves. The Valve Engineered Layout Operation (VELO) test device is built to experimentally study the flow characteristics of steam flowing inside the control valve with the CAMA input data. The Widows' Creek type control valve was selected as reference. CAMA is expected to be commercially utilized to accurately design and operate the turbine system for fossil as well as nuclear power

  1. Design and Development of High-Repetition-Rate Satellite Laser Ranging System

    Science.gov (United States)

    Choi, Eun-Jung; Bang, Seong-Cheol; Sung, Ki-Pyoung; Lim, Hyung-Chul; Jung, Chan-Gyu; Kim, In-Yeung; Choi, Jae-Seung

    2015-09-01

    The Accurate Ranging System for Geodetic Observation ? Mobile (ARGO-M) was successfully developed as the first Korean mobile Satellite Laser Ranging (SLR) system in 2012, and has joined in the International Laser Ranging Service (ILRS) tracking network, DAEdeoK (DAEK) station. The DAEK SLR station was approved as a validated station in April 2014, through the ILRS station ¡°data validation¡± process. The ARGO-M system is designed to enable 2 kHz laser ranging with millimeter-level precision for geodetic, remote sensing, navigation, and experimental satellites equipped with Laser Retroreflector Arrays (LRAs). In this paper, we present the design and development of a next generation high-repetition-rate SLR system for ARGO-M. The laser ranging rate up to 10 kHz is becoming an important issue in the SLR community to improve ranging precision. To implement high-repetition-rate SLR system, the High-repetition-rate SLR operation system (HSLR-10) was designed and developed using ARGO-M Range Gate Generator (A-RGG), so as to enable laser ranging from 50 Hz to 10 kHz. HSLR-10 includes both hardware controlling software and data post-processing software. This paper shows the design and development of key technologies of high-repetition-rate SLR system. The developed system was tested successfully at DAEK station and then moved to Sejong station, a new Korean SLR station, on July 1, 2015. HSLR-10 will begin normal operations at Sejong station in the near future.

  2. The rate coefficients of unimolecular reactions in the systems with power-law distributions

    Science.gov (United States)

    Yin, Cangtao; Guo, Ran; Du, Jiulin

    2014-08-01

    The rate coefficient formulae of unimolecular reactions are generalized to the systems with the power-law distributions based on nonextensive statistics, and the power-law rate coefficients are derived in the high and low pressure limits, respectively. The numerical analyses are made of the rate coefficients as functions of the ν-parameter, the threshold energy, the temperature and the number of degrees of freedom. We show that the new rate coefficients depend strongly on the ν-parameter different from one (thus from a Boltzmann-Gibbs distribution). Two unimolecular reactions, CH3CO→CH3+CO and CH3NC→CH3CN, are taken as application examples to calculate their power-law rate coefficients, which obtained with the ν-parameters slightly different from one can be exactly in agreement with all the experimental studies on these two reactions in the given temperature ranges.

  3. Infrared Tomography: Data Distribution System for Real-time Mass Flow Rate Measurement

    Directory of Open Access Journals (Sweden)

    Ruzairi Abdul Rahim

    2007-06-01

    Full Text Available The system developed in this research has the objective of measuring mass flow rate in an online mode. If a single computer is used as data processing unit, a longer time is needed to produce a measurement result. In the research carried out by previous researcher shows about 11.2 seconds is needed to obtain one mass flow rate result in the offline mode (using offline data. This insufficient real-time result will cause problems in a feedback control process when applying the system on industrial plants. To increase the refreshing rate of the measurement result, an investigation on a data distribution system is performed to replace the existing data processing unit.

  4. System for evaluation of the true average input-pulse rate

    International Nuclear Information System (INIS)

    Eichenlaub, D.P.; Garrett, P.

    1977-01-01

    The description is given of a digital radiation monitoring system making use of current digital circuit and microprocessor for rapidly processing the pulse data coming from remote radiation controllers. This system analyses the pulse rates in order to determine if a new datum is statistically the same as that previously received. Hence it determines the best possible average time for itself. So long as the true average pulse rate stays constant, the time required to establish an average can increase until the statistical error is under the desired level, i.e. 1%. When the digital processing of the pulse data indicates a change in the true average pulse rate, the time required to establish an average can be reduced so as to improve the response time of the system at the statistical error. This concept includes a fixed compromise between the statistical error and the response time [fr

  5. Renin-angiotensin system antagonists, glomerular filtration rate and blood pressure

    Directory of Open Access Journals (Sweden)

    D.D. Ivanov

    2018-02-01

    Full Text Available The article deals with the mModern data on the influence of renin-angiotensin system blockers on the glomerular filtration rate, the level of arterial pressure and the outcome of chronic kidney disease. The strategy of  rennin-angiotensine blockade is offered to be changed depending on the criteria va­lues of glomerular filtration rate: a combination of inhibitors of angiotensin-converting enzyme + angiotensin receptors blo­ckers, monotherapy and drug withdrawal in glomerular filtration rate under 15–30 ml/min/m2. The formula BRIMONEL for treatment of chronic kidney disease is given.

  6. The influence of nonbilinear system-bath coupling on quantum-mechanical activated rate processes

    International Nuclear Information System (INIS)

    Navrotskaya, Irina; Geva, Eitan

    2006-01-01

    The dependence of quantum-mechanical activated rate processes on the system-bath coupling strength was investigated in the case of a double-well nonbilinearly coupled to a harmonic bath, where the system-bath coupling is linear in the bath coordinates and nonlinear in the reaction coordinate. Such nonbilinear coupling is known to give rise to a classical friction kernel which is explicitly dependent on the reaction coordinate. We show that it can also lead to quantum-mechanical barrier-crossing rates, whose dependence on the system-bath coupling strength is qualitatively different from that observed in the quantum-mechanical bilinear case and classical nonbilinear case. More specifically, it is shown that the quantum-mechanical barrier-crossing rate may monotonically increase as a function of the system-bath coupling strength, in cases where the classical barrier-crossing rate goes through a turnover, and that the rate of quantum-mechanical barrier-crossing can be lower than that of classical barrier-crossing. We show that those purely quantum-mechanical effects are of a thermodynamical, rather than dynamical, nature, and that they originate from the difference in friction between the barrier top and the reactant and product wells. Our conclusions are supported by results obtained via the CMD method, which were also found to be in very good agreement with numerically exact calculations based on the QUAPI method

  7. Universal design of a microcontroller and IoT system to detect the heart rate

    Science.gov (United States)

    Uwamahoro, Raphael; Mushikiwabeza, Alexie; Minani, Gerard; Mohan Murari, Bhaskar

    2017-11-01

    Heart rate analysis provides vital information of the present condition of the human body. It helps medical professionals in diagnosis of various malfunctions of the body. The limitation of vision impaired and blind people to access medical devices cause a considerable loss of life. In this paper, we intended to develop a heart rate detection system that is usable for people with normal and abnormal vision. The system is based on a non-invasive method of measuring the variation of the tissue blood flow rate by means of a photo transmitter and detector through fingertip known as photoplethysmography (PPG). The signal detected is firstly passed through active low pass filter and then amplified by a two stages high gain amplifier. The amplified signal is feed into the microcontroller to calculate the heart rate and displays the heart beat via sound systems and Liquid Crystal Display (LCD). To distinguish arrhythmia, normal heart rate and abnormal working conditions of the system, recognition is provided in different sounds, LCD readings and Light Emitting Diodes (LED).

  8. Validation of a new control system for Elekta accelerators facilitating continuously variable dose rate

    DEFF Research Database (Denmark)

    Bertelsen, Anders; Lorenzen, Ebbe L; Brink, Carsten

    2011-01-01

    ) as well as BVDR. Using CVDR opposed to BVDR for VMAT has the potential of reducing the treatment time but may lead to lower dosimetric accuracy due to faster moving accelerator parts. Using D7 and a test version of Integrity, differences in ability to control the accelerator, treatment efficiency......Elekta accelerators controlled by the current clinically used accelerator control system, Desktop 7.01 (D7), uses binned variable dose rate (BVDR) for volumetric modulated arc therapy (VMAT). The next version of the treatment control system (Integrity) supports continuously variable dose rate (CVDR...

  9. Consumer perceptions of the Nutrition Facts table and front-of-pack nutrition rating systems.

    Science.gov (United States)

    Emrich, Teri E; Qi, Ying; Mendoza, Julio E; Lou, Wendy; Cohen, Joanna E; L'abbé, Mary R

    2014-04-01

    Preferences for, and consumer friendliness of, front-of-pack (FOP) nutrition rating systems have not been studied in a Canadian population, and studies comparing systems that are accompanied by mandatory labelling, such as Canada's Nutrition Facts table (NFt), are lacking. The purpose of this study was to evaluate 4 FOP systems relative to the NFt with respect to consumer friendliness and their influence on perceptions of the healthiness and nutrient content of food. Canadian consumers (n = 3029) participating in an online survey were randomized to score the consumer friendliness of 1 of 5 FOP conditions with or without an NFt and to score the healthiness and nutrient content of 2 foods using the provided label(s). The mean differences in scores were evaluated with analysis of covariance (ANCOVA) controlling for age, gender, and education, with Tukey-Kramer adjustments for multiple comparisons. The NFt received the highest scores of consumer friendliness with respect to liking, helpfulness, credibility, and influence on purchase decisions (p consumers still supported the implementation of a single, standardized FOP system, with the nutrient-specific systems (a "Traffic Light" and a Nutrition Facts FOP system) being preferred and scored as more consumer friendly than the summary indicator systems. Without the NFt, consumer ratings of the healthiness and calorie and nutrient content differed by FOP system. With the NFt present, consumers rated the healthiness and calorie and nutrient content similarly, except for those who saw the Traffic Light; their ratings were influenced by the Traffic Light's colours. The introduction of a single, standard, nutrient-specific FOP system to supplement the mandatory NFt should be considered by Canadian policy makers.

  10. Effect of vadose zone on the steady-state leakage rates from landfill barrier systems

    International Nuclear Information System (INIS)

    Celik, B.; Rowe, R.K.; Unlue, K.

    2009-01-01

    Leakage rates are evaluated for a landfill barrier system having a compacted clay liner (CCL) underlain by a vadose zone of variable thickness. A numerical unsaturated flow model SEEP/W is used to simulate the moisture flow regime and steady-state leakage rates for the cases of unsaturated zones with different soil types and thicknesses. The results of the simulations demonstrate that harmonic mean hydraulic conductivity of coarse textured vadose zones is 3-4 orders of magnitude less than saturated hydraulic conductivity; whereas, the difference is only one order of magnitude for fine textured vadose zones. For both coarse and fine textured vadose zones, the effective hydraulic conductivity of the barrier system and the leakage rate to an underlying aquifer increases with increasing thickness of the vadose zone and ultimately reaches an asymptotic value for a coarse textured vadose zone thickness of about 10 m and a fine textured vadose zone thickness of about 5 m. Therefore, the fine and coarse textured vadose zones thicker than about 5 m and 10 m, respectively, act as an effective part of the barrier systems examined. Although the thickness of vadose zone affects the effective hydraulic conductivity of the overall barrier system, the results demonstrated that the hydraulic conductivity of the CCL is the dominant factor controlling the steady-state leakage rates through barrier systems having single low permeability clay layers

  11. Electrical Rating of Concentrated Photovoltaic (CPV) Systems: Long-Term Performance Analysis and Comparison to Conventional PV Systems

    KAUST Repository

    Burhan, Muhammad

    2016-02-29

    The dynamic nature of meteorological data and the commercial availability of diverse photovoltaic systems, ranging from single-junction silicon-based PV panels to concentrated photovoltaic (CPV) systems utilizing multi-junction solar cells and a two-axis solar tracker, demand a simple but accurate methodology for energy planners and PV system designers to understand the economic feasibility of photovoltaic or renewable energy systems. In this paper, an electrical rating methodology is proposed that provides a common playing field for planners, consumers and PV manufacturers to evaluate the long-term performance of photovoltaic systems, as long-term electricity rating is deemed to be a quick and accurate method to evaluate economic viability and determine plant sizes and photovoltaic system power production. A long-term performance analysis based on monthly and electrical ratings (in kWh/m2/year) of two developed CPV prototypes, the Cassegrain mini dish and Fresnel lens CPVs with triple-junction solar cells operating under the meteorological conditions of Singapore, is presented in this paper. Performances are compared to other conventional photovoltaic systems.

  12. Stability Assessment of a System Comprising a Single Machine and Inverter with Scalable Ratings

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Brian B [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Lin, Yashen [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Gevorgian, Vahan [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Purba, Victor [University of Minnesota; Dhople, Sairaj [University of Minnesota

    2017-09-28

    From the inception of power systems, synchronous machines have acted as the foundation of large-scale electrical infrastructures and their physical properties have formed the cornerstone of system operations. However, power electronics interfaces are playing a growing role as they are the primary interface for several types of renewable energy sources and storage technologies. As the role of power electronics in systems continues to grow, it is crucial to investigate the properties of bulk power systems in low inertia settings. In this paper, we assess the properties of coupled machine-inverter systems by studying an elementary system comprised of a synchronous generator, three-phase inverter, and a load. Furthermore, the inverter model is formulated such that its power rating can be scaled continuously across power levels while preserving its closed-loop response. Accordingly, the properties of the machine-inverter system can be assessed for varying ratios of machine-to-inverter power ratings and, hence, differing levels of inertia. After linearizing the model and assessing its eigenvalues, we show that system stability is highly dependent on the interaction between the inverter current controller and machine exciter, thus uncovering a key concern with mixed machine-inverter systems and motivating the need for next-generation grid-stabilizing inverter controls.

  13. 42 CFR 413.220 - Methodology for calculating the per-treatment base rate under the ESRD prospective payment system...

    Science.gov (United States)

    2010-10-01

    ... rate under the ESRD prospective payment system effective January 1, 2011. 413.220 Section 413.220...-treatment base rate under the ESRD prospective payment system effective January 1, 2011. (a) Data sources. The methodology for determining the per treatment base rate under the ESRD prospective payment system...

  14. A "typodont" study of rate of orthodontic space closure: self-ligating systems vs. conventional systems.

    Science.gov (United States)

    Saporito, I; Butti, A C; Salvato, A; Biagi, R

    2011-01-01

    The aim of this study was to compare the effectiveness of space closure of two bracket systems, self-ligating and conventional ones, considering two systems with the same design and prescription. The experimental model of this study aims to identify in general if one type of system is more suitable for planning the extractive therapy, without considering the clinical aspect necessary for an adequate orthodontic approach. A resin maxilla without the first premolars was used to test the self-ligating and conventional brackets system. Space closure was achieved on 0.016x0.022" in stainless steel wires with nickel-titanium coil springs 150 grams in strength and 10 mm in length. Two experiment settings have been prepared. The first setting was made bonding conventional bracket on the right side and self-ligating on the left; the last one was made bonding self-ligating bracket on the right side and conventional on the left. All measurements (runs) have been repeated seven times for both settings. During the closing phase of extraction spaces both systems are equable since there are no significant statistical differences (P=0.70). Our typodont model showed no significant difference in the efficiency of space closure between the self-ligating bracket and conventional bracket tied with stainless steel ligatures.

  15. Free Energy Rate Density and Self-organization in Complex Systems

    OpenAIRE

    Georgiev, Georgi Yordanov; Gombos, Erin; Bates, Timothy; Henry, Kaitlin; Casey, Alexander; Daly, Michael

    2015-01-01

    One of the most important tasks in science is to understand the self-organization's arrow of time. To attempt this we utilize the connection between self-organization and non-equilibrium thermodynamics. Eric Chaisson calculated an exponential increase of Free Energy Rate Density (FERD) in Cosmic Evolution, from the Big Bang until now, paralleling the increase of system's structure. We term these studies "Devology". We connect FERD to the principle of least action for complex systems, driving ...

  16. A new rate-dependent model for high-frequency tracking performance enhancement of piezoactuator system

    Science.gov (United States)

    Tian, Lizhi; Xiong, Zhenhua; Wu, Jianhua; Ding, Han

    2017-05-01

    Feedforward-feedback control is widely used in motion control of piezoactuator systems. Due to the phase lag caused by incomplete dynamics compensation, the performance of the composite controller is greatly limited at high frequency. This paper proposes a new rate-dependent model to improve the high-frequency tracking performance by reducing dynamics compensation error. The rate-dependent model is designed as a function of the input and input variation rate to describe the input-output relationship of the residual system dynamics which mainly performs as phase lag in a wide frequency band. Then the direct inversion of the proposed rate-dependent model is used to compensate the residual system dynamics. Using the proposed rate-dependent model as feedforward term, the open loop performance can be improved significantly at medium-high frequency. Then, combining the with feedback controller, the composite controller can provide enhanced close loop performance from low frequency to high frequency. At the frequency of 1 Hz, the proposed controller presents the same performance as previous methods. However, at the frequency of 900 Hz, the tracking error is reduced to be 30.7% of the decoupled approach.

  17. Uncertainties and quantification of common cause failure rates and probabilities for system analyses

    International Nuclear Information System (INIS)

    Vaurio, Jussi K.

    2005-01-01

    Simultaneous failures of multiple components due to common causes at random times are modelled by constant multiple-failure rates. A procedure is described for quantification of common cause failure (CCF) basic event probabilities for system models using plant-specific and multiple-plant failure-event data. Methodology is presented for estimating CCF-rates from event data contaminated with assessment uncertainties. Generalised impact vectors determine the moments for the rates of individual systems or plants. These moments determine the effective numbers of events and observation times to be input to a Bayesian formalism to obtain plant-specific posterior CCF-rates. The rates are used to determine plant-specific common cause event probabilities for the basic events of explicit fault tree models depending on test intervals, test schedules and repair policies. Three methods are presented to determine these probabilities such that the correct time-average system unavailability can be obtained with single fault tree quantification. Recommended numerical values are given and examples illustrate different aspects of the methodology

  18. The Corrosion Inhibition Characteristics of Sodium Nitrite Using an On-line Corrosion Rate Measurement System

    International Nuclear Information System (INIS)

    Park, Mal-Yong; Kang, Dae-Jin; Moon, Jeon-Soo

    2015-01-01

    An on-line corrosion rate measurement system was developed using a personal computer, a data acquisition board and program, and a 2-electrode corrosion probe. Reliability of the developed system was confirmed with through comparison test. With this system, the effect of sodium nitrite (NaNO 2 ) as a corrosion inhibitor were studied on iron and aluminum brass that were immersed in sodium chloride (NaCl) solution. Corrosion rate was measured based on the linear polarization resistance method. The corrosion rates of aluminum brass and iron in 1% NaCl solutions were measured to be 0.290 mm per year (mmpy) and 0.2134 mmpy, respectively. With the addition of 200 ppm of NO 2 - , the corrosion rates decreased to 0.0470 mmpy and 0.0254 mmpy. The addition of NO 2 - caused a decrease in corrosion rates of both aluminum brass and iron, yet the NO 2 - acted as a more effective corrosion inhibitor for iron. than aluminum brass

  19. The effect of using an audience response system on learning, motivation and information retention in the orthodontic teaching of undergraduate dental students: a cross-over trial.

    Science.gov (United States)

    Dhaliwal, Harmeet Kaur; Allen, Mark; Kang, Jing; Bates, Claire; Hodge, Trevor

    2015-06-01

    New methods of teaching and learning are constantly being sought in the adult learning environment. Audience Response Systems (ARS) have been used in many different learning environments, especially in the field of medical education. The objective of this investigation was to ascertain the effect of ARS use in undergraduate teaching in a UK dental school. A cross-over clustered randomized educational trial. Leeds Dental Institute. Year 4 undergraduate dental students in orthodontics. Students at Leeds Dental Institute were taught two different topics within the curriculum to test the use of ARS in a cross-over trial. A questionnaire was delivered to the test (ARS) and control (non-ARS) groups. The response rate to the questionnaires was 89·5% (test group) and 82·9% (control group). The ARS enabled students to perform better as shown by knowledge retention (P = 0·013). Students found the seminar more interesting (P = 0·013), easier to concentrate (P = 0·025) and easier to participate in (P = 0·020) when ARS was used. When ARS was used, students were more able to answer questions (P<0·0001), were more likely to prepare for the seminar (P<0·0001) and significantly preferred using ARS (P<0·0001). ARS was found to significantly improve student concentration and participation in small group seminar teaching and significantly improved knowledge retention. ARS may be useful in facilitating orthodontic teaching in the future.

  20. Data base of system-average dose rates at nuclear power plants: Final report

    International Nuclear Information System (INIS)

    Beal, S.K.; Britz, W.L.; Cohen, S.C.; Goldin, A.S.; Goldin, D.J.

    1987-10-01

    In this work, a data base is derived of area dose rates for systems and components listed in the Energy Economic Data Base (EEDB). The data base is derived from area surveys obtained during outages at four boiling water reactors (BWRs) at three stations and eight pressurized water reactors (PWRs) at four stations. Separate tables are given for BWRs and PWRs. These tables may be combined with estimates of labor hours to provide order-of-magnitude estimates of exposure for purposes of regulatory analysis. They are only valid for work involving entire systems or components. The estimates of labor hours used in conjunction with the dose rates to estimate exposure must be adjusted to account for in-field time. Finally, the dose rates given in the data base do not reflect ALARA considerations. 11 refs., 2 figs., 3 tabs

  1. The principle and data analysis of online monitoring system of containment leak rate

    International Nuclear Information System (INIS)

    Zhang Chunwei; Yang Yongdeng; Qiao Yu; Liang Bo

    2014-01-01

    The use of online monitoring system of containment leak rate (EPP) in Qinshan 2nd nuclear power plant is introduced. When the containment leak rate reaches the operational limit, the system will automatically alarm and inform the unit operator to take the necessary action. But it is found that the EPP will give a mendacious alarm of 'Containment leak rate abnormity' once in a while during use. The mendacious alarm has an effect on the normal operation of the unit. The reason of the mendacious alarm is analyzed. The data monitored by the EPP are relative hysteretic and the veracity of the flow of compressed air into the containment has a significant influence on the data monitored by the EPP. (authors)

  2. MAGIK: a Monte Carlo system for computing induced residual activation dose rates

    International Nuclear Information System (INIS)

    Barish, J.; Gabriel, T.A.; Alsmiller, R.G. Jr.

    1979-08-01

    The photon dose rate from the induced activity produced by sustained bombardment of materials by neutrons and charged particles may present a significant radiation hazard. To minimize this hazard, the material configuration must be so designed that the photon dose rate decays to an acceptable level soon after the source beam is turned off. MAGIK calculates the time-independent photon dose rates that result from activities produced by nucleon-nucleus and meson-nucleus collisions over a wide range of energies. The system has been used both for high-energy accelerator studies and for fusion reactor studies. In the MAGIK system the lengthy photon transport calculations are carried out independent of time, and the time dependence is introduced in the final program, thereby permitting study of various operating scenarios with a minimum computing cost

  3. Quality control of system of imaging for rectal ultrasound for implants seed prostate low rate

    International Nuclear Information System (INIS)

    Luquero Llopis, N.; Ferrer Gracia, C.; Huertas Martinez, C.; Huerga Cabrerizo, C.; Corredoira Silva, E.; Serrada Hierro, A.

    2013-01-01

    In this work, the objective is the evaluation of the image system used in implants of prostate of low rate held at our hospital, for maximum control on the placement of the seeds in the patient and therefore carried out dosimetry. (Author)

  4. Urinary albumin and beta 2-microglobulin excretion rates in patients with systemic lupus erythematosus

    DEFF Research Database (Denmark)

    Parving, H H; Sørensen, S F; Mogensen, C E

    1980-01-01

    The daily urinary albumin and beta 2-microglobulin excretion rates were measured with sensitive radioimmunoassays in 14 patients with systemic lupus erythematosus (SLE). The duration of SLE ranged from 0.5 to 18 years, mean 10 years. The mean age was 37 years. All patients except 5 received...

  5. Reaction rate estimation of controlled-release antifouling paint binders: Rosin-based systems

    DEFF Research Database (Denmark)

    Meseguer Yebra, Diego; Kiil, Søren; Dam-Johansen, Kim

    2005-01-01

    Biofouling on ship hulls is prevented by the use of antifouling (A/F) paints. Typically, sea water soluble rosin or rosin-derivatives are used as the primary means of adjusting the polishing rate of the current chemically active self-polishing paint systems to a suitable value. Previous studies h...

  6. FIRES: Fire Information Retrieval and Evaluation System - A program for fire danger rating analysis

    Science.gov (United States)

    Patricia L. Andrews; Larry S. Bradshaw

    1997-01-01

    A computer program, FIRES: Fire Information Retrieval and Evaluation System, provides methods for evaluating the performance of fire danger rating indexes. The relationship between fire danger indexes and historical fire occurrence and size is examined through logistic regression and percentiles. Historical seasonal trends of fire danger and fire occurrence can be...

  7. Synergy between building rating systems and design methodology for intellingent and green buildings

    NARCIS (Netherlands)

    Zeiler, W.; Boxem, G.; Plesser, S.

    2008-01-01

    There is a strong need for more efficient and more sustainable buildings. At present it is difficult to define the performance of buildings in an objective way to efficiency and sustainability. Goal of this project is to examine and to understand differences between different building rating systems

  8. 78 FR 64930 - Open Forum on College Value and Affordability and College Ratings System

    Science.gov (United States)

    2013-10-30

    ...-437-0833), or email us at: [email protected] . Or write to: U.S. Department of Education... DEPARTMENT OF EDUCATION Open Forum on College Value and Affordability and College Ratings System AGENCY: Office of the Under Secretary, Department of Education. ACTION: Notice. SUMMARY: In August 2013...

  9. 76 FR 9640 - Prevailing Rate Systems: Santa Clara, CA, Tulsa County, OK, and Angelina County, TX

    Science.gov (United States)

    2011-02-22

    ... OFFICE OF PERSONNEL MANAGEMENT 5 CFR Part 532 RIN 3206-AM22 Prevailing Rate Systems: Santa Clara... County, Texas, as an area of application to the Dallas, TX, NAF FWS wage area. The Federal Prevailing.... Accordingly, the U.S. Office of Personnel Management amends 5 CFR part 532 as follows: PART 532--PREVAILING...

  10. Classroom Quality Rating Systems: How Do Teachers Prepare and What Do They Think about the Process?

    Science.gov (United States)

    Scott-Little, Catherine; Brown, E. Glyn; Hooks, Laura McDonald; Marshall, Betty Jo

    2008-01-01

    Working with the South Carolina Department of Education, the authors surveyed prekindergarten and kindergarten teachers whose schools participated in a quality rating system to see what they did to get ready for the observation and what they thought of the evaluation process. The authors also asked them what they thought about the quality of their…

  11. Higher contamination rate than usual. Treatment and disinfection of water in hot whirlpool systems

    Energy Technology Data Exchange (ETDEWEB)

    Herschman, W

    1985-10-01

    Hot whirlpools must meet the hygienic standards set in the Federal Law Concerning Prevention of Epidemics of 18 Dec 1979. The low water volume of whirlpool systems and the extraordinary contamination rate in uninterrupted operation require a specific water treatment and disinfestation technology to make up for the poor buffer capacity of the low water volume. (orig./BWI).

  12. An expert system for estimating production rates and costs for hardwood group-selection harvests

    Science.gov (United States)

    Chris B. LeDoux; B. Gopalakrishnan; R. S. Pabba

    2003-01-01

    As forest managers shift their focus from stands to entire ecosystems alternative harvesting methods such as group selection are being used increasingly. Results of several field time and motion studies and simulation runs were incorporated into an expert system for estimating production rates and costs associated with harvests of group-selection units of various size...

  13. Analysis of Autonomic Nervous System Functional Age and Heart Rate Variability in Mine Workers

    Directory of Open Access Journals (Sweden)

    Vasicko T

    2016-04-01

    Full Text Available Introduction: Heavy working conditions and many unpropitious factors influencing workers health participate in development of various health disorders, among other autonomic cardiovascular regulation malfunction. The aim of this study is to draw a comparison of autonomic nervous system functional age and heart rate variability changes between workers with and without mining occupational exposure.

  14. Information rates of next-generation long-haul optical fiber systems using coded modulation

    NARCIS (Netherlands)

    Liga, G.; Alvarado, A.; Agrell, E.; Bayvel, P.

    2017-01-01

    A comprehensive study of the coded performance of long-haul spectrally-efficient WDM optical fiber transmission systems with different coded modulation decoding structures is presented. Achievable information rates are derived for three different square QAM formats and the optimal format is

  15. NFDRSPC: The National Fire-Danger Rating System on a Personal Computer

    Science.gov (United States)

    Bryan G. Donaldson; James T. Paul

    1990-01-01

    This user's guide is an introductory manual for using the 1988 version (Burgan 1988) of the National Fire-Danger Rating System on an IBM PC or compatible computer. NFDRSPC is a window-oriented, interactive computer program that processes observed and forecast weather with fuels data to produce NFDRS indices. Other program features include user-designed display...

  16. RF imperfections in high-rate wireless systems : impact and digital compensation

    NARCIS (Netherlands)

    Schenk, T.C.W.

    2008-01-01

    Wireless communication systems are persistently applying wider bandwidths, larger signal dynamics and higher carrier frequencies to fulfil the demand for higher data rates. This results in an ever increasing demand on the performance of low-cost and power-efficient radio frequency (RF) front-ends.

  17. Sum-rate performance of large centralized and distributed MU-MIMO systems in indoor WLAN

    NARCIS (Netherlands)

    Wang, Q.; Debbarma, D.; Lo, A.; Niemegeers, I.; Heemstra, Sonia

    2015-01-01

    Large MIMO systems are recognized as an effective technique for increasing the spectral and energy efficiency of wireless networks. The attractiveness of this technique for WLAN is that it can be an alternative approach to cell densification for providing high data rate wireless access. Here we

  18. Low energy electron diffraction (LEED) and sum frequency generation (SFG) vibrational spectroscopy studies of solid-vacuum, solid-air and solid-liquid interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Hoffer, Saskia [Univ. of California, Berkeley, CA (United States)

    2002-01-01

    Electron based surface probing techniques can provide detailed information about surface structure or chemical composition in vacuum environments. The development of new surface techniques has made possible in situ molecular level studies of solid-gas interfaces and more recently, solid-liquid interfaces. The aim of this dissertation is two-fold. First, by using novel sample preparation, Low Energy Electron Diffraction (LEED) and other traditional ultra high vacuum (UHV) techniques are shown to provide new information on the insulator/vacuum interface. The surface structure of the classic insulator NaCl has been determined using these methods. Second, using sum frequency generation (SFG) surface specific vibrational spectroscopy studies were performed on both the biopolymer/air and electrode/electrolyte interfaces. The surface structure and composition of polyetherurethane-silicone copolymers were determined in air using SFG, atomic force microscopy (AFM), and X-ray photoelectron spectroscopy (XPS). SFG studies of the electrode (platinum, gold and copper)/electrolyte interface were performed as a function of applied potential in an electrochemical cell.

  19. Cross-cultural Adaptation and Linguistic Validation of the Korean Version of the Leeds Assessment of Neuropathic Symptoms and Signs Pain Scale

    Science.gov (United States)

    Park, Cholhee; Lee, Youn-Woo; Yoon, Duck Mi; Kim, Do Wan; Nam, Da Jeong

    2015-01-01

    Distinction between neuropathic pain and nociceptive pain helps facilitate appropriate management of pain; however, diagnosis of neuropathic pain remains a challenge. The aim of this study was to develop a Korean version of the Leeds Assessment of Neuropathic Symptoms and Signs (LANSS) pain scale and assess its reliability and validity. The translation and cross-cultural adaptation of the original LANSS pain scale into Korean was established according to the published guidelines. The Korean version of the LANSS pain scale was applied to a total of 213 patients who were expertly diagnosed with neuropathic (n = 113) or nociceptive pain (n = 100). The Korean version of the scale had good reliability (Cronbach's α coefficient = 0.815, Guttman split-half coefficient = 0.800). The area under the receiver operating characteristic curve was 0.928 with a 95% confidence interval of 0.885-0.959 (P < 0.001), suggesting good discriminate value. With a cut-off score ≥ 12, sensitivity was 72.6%, specificity was 98.0%, and the positive and negative predictive values were 98% and 76%, respectively. The Korean version of the LANSS pain scale is a useful, reliable, and valid instrument for screening neuropathic pain from nociceptive pain. PMID:26339176

  20. Cross-Cultural Psychometric Assessment of the Leeds Assessment of Neuropathic Symptoms and Signs (LANSS) Pain Scale in the Portuguese Population.

    Science.gov (United States)

    Barbosa, Margarida; Bennett, Michael I; Verissimo, Ramiro; Carvalho, Davide

    2014-09-01

    Chronic pain is a well-known phenomenon. The differential diagnosis between neuropathic and nociceptive pain syndromes is a challenge. Consequently, assessment instruments that can distinguish between these conditions in a standardized way are of the utmost importance. The Leeds Assessment of Neuropathic Symptoms and Signs (LANSS) is a screening tool developed to identify chronic neuropathic pain. The aim of this study was the Portuguese language translation, linguistic adaptation of the LANSS pain scale, its semantic validation, internal consistency, temporal stability, as well its validity and discriminative power. LANSS Portuguese version scale was applied to 165 consecutive patients attending the pain clinic: 103 fulfilled the clinical criteria for the diagnosis of pain of neuropathic origin and the remaining 62 fulfilled the criteria for nociceptive pain. The scale proved to be an internally consistent (Cronbach's alpha = 0.78) and reliable instrument with good test-retest stability (r = 0.7; P cross-cultural version is a reliable and valid instrument for the differentiation of this type of pain. Its usage is recommended. © 2013 World Institute of Pain.

  1. LEED-IV study of the rutile TiO2(110)-1x2 surface with a Ti-interstitial added-row reconstruction

    International Nuclear Information System (INIS)

    Blanco-Rey, M.; Mendez, J.; Lopez, M. F.; Roman, E.; Martin-Gago, J. A.; Andres, P. L. de; Abad, J.; Rogero, C.

    2007-01-01

    Upon sputtering and annealing in UHV at ∼1000 K, the rutile TiO 2 (110) surface undergoes a 1x1→1x2 phase transition. The resulting 1x2 surface is Ti rich, formed by strands of double Ti rows as seen on scanning tunneling microscopic images, but its detailed structure and composition have been subject to debate in the literature for years. Recently, Park et al. [Phys. Rev. Lett. 96, 226105 (2006)] have proposed a model where Ti atoms are located on interstitial sites with Ti 2 O stoichiometry. This model, when it is analyzed using LEED-IV data [Phys. Rev. Lett. 96, 0055502 (2006)], does not yield an agreement between theory and experiment as good as the previous best fit for Onishi and Iwasawa's model for the long-range 1x2 reconstruction. Therefore, the Ti 2 O 3 added row is the preferred one from the point of view low-energy electron diffraction

  2. The evolutionary synchronization of the exchange rate system in ASEAN+6

    Science.gov (United States)

    Feng, Xiaobing; Hu, Haibo; Wang, Xiaofan

    2010-12-01

    Although there are extensive researches on the behavior of the world currency network, the complexity of the Asian regional currency system is not well understood regardless of its importance. Using daily exchange rates this paper examines exchange rate co-movements in the region before and after the China exchange rate reform. It was found that the correlation between Asian currencies and the US Dollar, the previous regional key currency has become weaker and intra-Asia interactions have increased. Cross sample entropy and cross entropy approaches are also applied to examine the synchrony behavior among the Asian currencies. The study also shows that the Asian exchange rate markets featured are neither stochastic nor efficient. These findings may shed some light on the in-depth understanding of collective behaviors in a regional currency network; they will also lay a theoretical foundation for further policy formulation in Asian currency integration.

  3. Effects of data sampling rate on image quality in fan-beam-CT system

    International Nuclear Information System (INIS)

    Iwata, Akira; Yamagishi, Nobutoshi; Suzumura, Nobuo; Horiba, Isao.

    1984-01-01

    Investigation was made into the relationship between spatial resolution or artifacts and data sampling rate in order to pursue the causes of the degradation of CT image quality by computer simulation. First the generation of projection data and reconstruction calculating process are described, and then the results are shown about the relation between angular sampling interval and spatical resolution or artifacts, and about the relation between projection data sampling interval and spatial resolution or artifacts. It was clarified that the formulation of the relationship between spatial resolution and data sampling rate performed so far for parallel X-ray beam was able to be applied to fan beam. As a conclusion, when other reconstruction parameters are the same in fan beam CT systems, spatial resolution can be determined by projection data sampling rate rather than angular sampling rate. The mechanism of artifact generation due to the insufficient number of angular samples was made clear. It was also made clear that there was a definite relationship among measuring region, angular sampling rate and projection data sampling rate, and the amount of artifacts depending upon projection data sampling rate was proportional to the amount of spatial frequency components (Aliasing components) of a test object above the Nyquist frequency of projection data. (Wakatsuki, Y.)

  4. Lessons Learned From The 200 West Pump And Treatment Facility Construction Project At The US DOE Hanford Site - A Leadership For Energy And Environmental Design (LEED) Gold-Certified Facility

    International Nuclear Information System (INIS)

    Dorr, Kent A.; Ostrom, Michael J.; Freeman-Pollard, Jhivaun R.

    2012-01-01

    CH2M Hill Plateau Remediation Company (CHPRC) designed, constructed, commissioned, and began operation of the largest groundwater pump and treatment facility in the U.S. Department of Energy's (DOE) nationwide complex. This one-of-a-kind groundwater pump and treatment facility, located at the Hanford Nuclear Reservation Site (Hanford Site) in Washington State, was built in an accelerated manner with American Recovery and Reinvestment Act (ARRA) funds and has attained Leadership in Energy and Environmental Design (LEED) GOLD certification, which makes it the first non-administrative building in the DOE Office of Environmental Management complex to earn such an award. There were many contractual, technical, configuration management, quality, safety, and LEED challenges associated with the design, procurement, construction, and commissioning of this $95 million, 52,000 ft groundwater pump and treatment facility. This paper will present the Project and LEED accomplishments, as well as Lessons Learned by CHPRC when additional ARRA funds were used to accelerate design, procurement, construction, and commissioning of the 200 West Groundwater Pump and Treatment (2W PandT) Facility to meet DOE's mission of treating contaminated groundwater at the Hanford Site with a new facility by June 28, 2012

  5. Lessons Learned From The 200 West Pump And Treatment Facility Construction Project At The US DOE Hanford Site - A Leadership For Energy And Environmental Design (LEED) Gold-Certified Facility

    Energy Technology Data Exchange (ETDEWEB)

    Dorr, Kent A. [CH2M HILL Plateau Remediation Company, Richland, WA (United States); Ostrom, Michael J. [CH2M HILL Plateau Remediation Company, Richland, WA (United States); Freeman-Pollard, Jhivaun R. [CH2M HILL Plateau Remediation Company, Richland, WA (United States)

    2012-11-14

    CH2M Hill Plateau Remediation Company (CHPRC) designed, constructed, commissioned, and began operation of the largest groundwater pump and treatment facility in the U.S. Department of Energy's (DOE) nationwide complex. This one-of-a-kind groundwater pump and treatment facility, located at the Hanford Nuclear Reservation Site (Hanford Site) in Washington State, was built in an accelerated manner with American Recovery and Reinvestment Act (ARRA) funds and has attained Leadership in Energy and Environmental Design (LEED) GOLD certification, which makes it the first non-administrative building in the DOE Office of Environmental Management complex to earn such an award. There were many contractual, technical, configuration management, quality, safety, and LEED challenges associated with the design, procurement, construction, and commissioning of this $95 million, 52,000 ft groundwater pump and treatment facility. This paper will present the Project and LEED accomplishments, as well as Lessons Learned by CHPRC when additional ARRA funds were used to accelerate design, procurement, construction, and commissioning of the 200 West Groundwater Pump and Treatment (2W P&T) Facility to meet DOE's mission of treating contaminated groundwater at the Hanford Site with a new facility by June 28, 2012.

  6. Prototype Systems for Measuring Outdoor Air Intake Rates in Rooftop Air Handlers

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Chan, Wanyu R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hotchi, Toshifumi [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-01-01

    The widespread absence of systems for real-time measurement and feedback control, of minimum outdoor air intake rates in HVAC systems contributes to the poor control of ventilation rates in commercial buildings. Ventilation rates affect building energy consumption and influence occupant health. The project designed fabricated and tested four prototypes of systems for measuring rates of outdoor air intake into roof top air handlers. All prototypes met the ±20% accuracy target at low wind speeds, with all prototypes accurate within approximately ±10% after application of calibration equations. One prototype met the accuracy target without a calibration. With two of four prototype measurement systems, there was no evidence that wind speed or direction affected accuracy; however, winds speeds were generally below usually 3.5 m s-1 (12.6 km h-1) and further testing is desirable. The airflow resistance of the prototypes was generally less than 35 Pa at maximum RTU air flow rates. A pressure drop of this magnitude will increase fan energy consumption by approximately 4%. The project did not have resources necessary to estimate costs of mass produced systems. The retail cost of components and materials used to construct prototypes ranged from approximately $1,200 to $1,700. The test data indicate that the basic designs developed in this project, particularly the designs of two of the prototypes, have considerable merit. Further design refinement, testing, and cost analysis would be necessary to fully assess commercial potential. The designs and test results will be communicated to the HVAC manufacturing community.

  7. Efficiency analysis in the application of indicators LEED-ND, the arid zone of the north of Mexico, case of study: Parajes del Sur, Ciudad Juarez, Chihuahua; Analisis de la eficiencia en la aplicacion de indicadores LEED-ND, en la zona arida del norte de Mexico, caso de estudio: parajes del sur, Ciudad Juarez, Chihuahua

    Energy Technology Data Exchange (ETDEWEB)

    Pena Barrera, Leticia [Universidad Autonoma de Ciudad Juarez, Chihuahua (Mexico)

    2009-01-15

    This article presents the analysis realized to the urban design of a colony applying the indicators of The Leadership in Energy (LEED-ND). The advantages that represent as far as impact are established and also the limits are pointed out, evaluating their efficiency in the application of indicators to improve performance and energy saving. Based on the analysis applied to the colony under study, some right solutions in the urban design are obtained that should be established as a part of the in force standardization. Nevertheless, the follow up to this same company in other developments, reflects that the proposals are not determined as a strategy of self planning but only to fulfill the asked requirements, obtaining a result with smaller impact and as an index that allows offering residential alternatives in the city tending to the sustained development. [Spanish] Este articulo presenta el analisis realizado al diseno urbano de un fraccionamiento aplicando los indicadores de The Leadership in Energy (LEED-ND). Se establecen las ventajas que presenta en cuanto a impacto y tambien se senalan las limitantes, evaluando su eficiencia en la aplicacion de indicadores para mejorar desempeno y ahorro energetico. Con base en el analisis aplicado al fraccionamiento en estudio, se tienen algunas soluciones acertadas en el diseno urbano que debieran establecerse como parte de la normatividad vigente, sin embargo, el seguimiento a esta misma empresa en otros desarrollos, refleja que las propuestas no estan determinadas como una estrategia de planeacion propia sino unicamente para cumplir con los requerimientos solicitados, obteniendo un resultado con menor impacto y como indice que permitan ofrecer alternativas habitacionales en la ciudad tendientes al desarrollo sostenido.

  8. A pilot rating scale for evaluating failure transients in electronic flight control systems

    Science.gov (United States)

    Hindson, William S.; Schroeder, Jeffery A.; Eshow, Michelle M.

    1990-01-01

    A pilot rating scale was developed to describe the effects of transients in helicopter flight-control systems on safety-of-flight and on pilot recovery action. The scale was applied to the evaluation of hardovers that could potentially occur in the digital flight-control system being designed for a variable-stability UH-60A research helicopter. Tests were conducted in a large moving-base simulator and in flight. The results of the investigation were combined with existing airworthiness criteria to determine quantitative reliability design goals for the control system.

  9. Coordinated Secondary Control for Balanced Discharge Rate of Energy Storage System in Islanded AC Microgrids

    DEFF Research Database (Denmark)

    Guan, Yajuan; Quintero, Juan Carlos Vasquez; Guerrero, Josep M.

    2016-01-01

    A coordinated secondary control approach based on an autonomous current-sharing control strategy for balancing the discharge rates of energy storage systems (ESSs) in islanded AC microgrids is proposed in this paper. The coordinated secondary controller can regulate the power outputs of distributed...... incidents and unintentional outages in DG units, but also aims to provide a fast transient response and an accurate output-current-sharing performance. A complete root locus analysis is given in order to achieve system stability and parameter sensitivity. Experimental results are presented to show...... the performance of the whole system and to verify the effectiveness of the proposed controller....

  10. A minimum bit error-rate detector for amplify and forward relaying systems

    KAUST Repository

    Ahmed, Qasim Zeeshan; Alouini, Mohamed-Slim; Aissa, Sonia

    2012-01-01

    In this paper, a new detector is being proposed for amplify-and-forward (AF) relaying system when communicating with the assistance of L number of relays. The major goal of this detector is to improve the bit error rate (BER) performance of the system. The complexity of the system is further reduced by implementing this detector adaptively. The proposed detector is free from channel estimation. Our results demonstrate that the proposed detector is capable of achieving a gain of more than 1-dB at a BER of 10 -5 as compared to the conventional minimum mean square error detector when communicating over a correlated Rayleigh fading channel. © 2012 IEEE.

  11. A minimum bit error-rate detector for amplify and forward relaying systems

    KAUST Repository

    Ahmed, Qasim Zeeshan

    2012-05-01

    In this paper, a new detector is being proposed for amplify-and-forward (AF) relaying system when communicating with the assistance of L number of relays. The major goal of this detector is to improve the bit error rate (BER) performance of the system. The complexity of the system is further reduced by implementing this detector adaptively. The proposed detector is free from channel estimation. Our results demonstrate that the proposed detector is capable of achieving a gain of more than 1-dB at a BER of 10 -5 as compared to the conventional minimum mean square error detector when communicating over a correlated Rayleigh fading channel. © 2012 IEEE.

  12. Vision-based system for the control and measurement of wastewater flow rate in sewer systems.

    Science.gov (United States)

    Nguyen, L S; Schaeli, B; Sage, D; Kayal, S; Jeanbourquin, D; Barry, D A; Rossi, L

    2009-01-01

    Combined sewer overflows and stormwater discharges represent an important source of contamination to the environment. However, the harsh environment inside sewers and particular hydraulic conditions during rain events reduce the reliability of traditional flow measurement probes. In the following, we present and evaluate an in situ system for the monitoring of water flow in sewers based on video images. This paper focuses on the measurement of the water level based on image-processing techniques. The developed image-based water level algorithms identify the wall/water interface from sewer images and measure its position with respect to real world coordinates. A web-based user interface and a 3-tier system architecture enable the remote configuration of the cameras and the image-processing algorithms. Images acquired and processed by our system were found to reliably measure water levels and thereby to provide crucial information leading to better understand particular hydraulic behaviors. In terms of robustness and accuracy, the water level algorithm provided equal or better results compared to traditional water level probes in three different in situ configurations.

  13. Efficient Data Transfer Rate and Speed of Secured Ethernet Interface System

    Science.gov (United States)

    Ghanti, Shaila

    2016-01-01

    Embedded systems are extensively used in home automation systems, small office systems, vehicle communication systems, and health service systems. The services provided by these systems are available on the Internet and these services need to be protected. Security features like IP filtering, UDP protection, or TCP protection need to be implemented depending on the specific application used by the device. Every device on the Internet must have network interface. This paper proposes the design of the embedded Secured Ethernet Interface System to protect the service available on the Internet against the SYN flood attack. In this experimental study, Secured Ethernet Interface System is customized to protect the web service against the SYN flood attack. Secured Ethernet Interface System is implemented on ALTERA Stratix IV FPGA as a system on chip and uses the modified SYN flood attack protection method. The experimental results using Secured Ethernet Interface System indicate increase in number of genuine clients getting service from the server, considerable improvement in the data transfer rate, and better response time during the SYN flood attack. PMID:28116350

  14. Efficient Data Transfer Rate and Speed of Secured Ethernet Interface System.

    Science.gov (United States)

    Ghanti, Shaila; Naik, G M

    2016-01-01

    Embedded systems are extensively used in home automation systems, small office systems, vehicle communication systems, and health service systems. The services provided by these systems are available on the Internet and these services need to be protected. Security features like IP filtering, UDP protection, or TCP protection need to be implemented depending on the specific application used by the device. Every device on the Internet must have network interface. This paper proposes the design of the embedded Secured Ethernet Interface System to protect the service available on the Internet against the SYN flood attack. In this experimental study, Secured Ethernet Interface System is customized to protect the web service against the SYN flood attack. Secured Ethernet Interface System is implemented on ALTERA Stratix IV FPGA as a system on chip and uses the modified SYN flood attack protection method. The experimental results using Secured Ethernet Interface System indicate increase in number of genuine clients getting service from the server, considerable improvement in the data transfer rate, and better response time during the SYN flood attack.

  15. Effectiveness of a Novel Specimen Collection System in Reducing Blood Culture Contamination Rates.

    Science.gov (United States)

    Bell, Mary; Bogar, Catherine; Plante, Jessica; Rasmussen, Kristen; Winters, Sharon

    2018-04-20

    False-positive blood-culture results due to skin contamination of samples remain a persistent problem for health care providers. Our health system recognized that our rates of contamination across the 4 emergency department campuses were above the national average. A unique specimen collection system was implemented throughout the 4 emergency departments and became the mandatory way to collect adult blood cultures. The microbiology laboratory reported contamination rates weekly to manage potential problems; 7 months of data are presented here. There was an 82.8% reduction in false positives with the unique specimen collection system compared with the standard method (chi-squared test with Yates correction, 2-tailed, P = 0.0001). Based on the historical 3.52% rate of blood-culture contamination for our health facilities, 2.92 false positives were prevented for every 100 blood cultures drawn, resulting from adoption of the unique specimen collection system as the standard of care. This unique collection system can reduce the risk of blood culture contamination significantly and is designed to augment, rather than replace, the standard phlebotomy protocol already in use in most health care settings. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Fuzzy Based Decision Support System for Condition Assessment and Rating of Bridges

    Science.gov (United States)

    Srinivas, Voggu; Sasmal, Saptarshi; Karusala, Ramanjaneyulu

    2016-09-01

    In this work, a knowledge based decision support system has been developed to efficiently handle the issues such as distress diagnosis, assessment of damages and condition rating of existing bridges towards developing an exclusive and robust Bridge Management System (BMS) for sustainable bridges. The Knowledge Based Expert System (KBES) diagnoses the distresses and finds the cause of distress in the bridge by processing the data which are heuristic and combined with site inspection results, laboratory test results etc. The coupling of symbolic and numeric type of data has been successfully implemented in the expert system to strengthen its decision making process. Finally, the condition rating of the bridge is carried out using the assessment results obtained from the KBES and the information received from the bridge inspector. A systematic procedure has been developed using fuzzy mathematics for condition rating of bridges by combining the fuzzy weighted average and resolution identity technique. The proposed methodologies and the decision support system will facilitate in developing a robust and exclusive BMS for a network of bridges across the country and allow the bridge engineers and decision makers to carry out maintenance of bridges in a rational and systematic way.

  17. Using field feedback to estimate failure rates of safety-related systems

    International Nuclear Information System (INIS)

    Brissaud, Florent

    2017-01-01

    The IEC 61508 and IEC 61511 functional safety standards encourage the use of field feedback to estimate the failure rates of safety-related systems, which is preferred than generic data. In some cases (if “Route 2_H” is adopted for the 'hardware safety integrity constraints”), this is even a requirement. This paper presents how to estimate the failure rates from field feedback with confidence intervals, depending if the failures are detected on-line (called 'detected failures', e.g. by automatic diagnostic tests) or only revealed by proof tests (called 'undetected failures'). Examples show that for the same duration and number of failures observed, the estimated failure rates are basically higher for “undetected failures” because, in this case, the duration observed includes intervals of time where it is unknown that the elements have failed. This points out the need of using a proper approach for failure rates estimation, especially for failures that are not detected on-line. Then, this paper proposes an approach to use the estimated failure rates, with their uncertainties, for PFDavg and PFH assessment with upper confidence bounds, in accordance with IEC 61508 and IEC 61511 requirements. Examples finally show that the highest SIL that can be claimed for a safety function can be limited by the 90% upper confidence bound of PFDavg or PFH. The requirements of the IEC 61508 and IEC 61511 relating to the data collection and analysis should therefore be properly considered for the study of all safety-related systems. - Highlights: • This paper deals with requirements of the IEC 61508 and IEC 61511 for using field feedback to estimate failure rates of safety-related systems. • This paper presents how to estimate the failure rates from field feedback with confidence intervals for failures that are detected on-line. • This paper presents how to estimate the failure rates from field feedback with confidence intervals for failures that are only revealed by

  18. Confidence Intervals Verification for Simulated Error Rate Performance of Wireless Communication System

    KAUST Repository

    Smadi, Mahmoud A.

    2012-12-06

    In this paper, we derived an efficient simulation method to evaluate the error rate of wireless communication system. Coherent binary phase-shift keying system is considered with imperfect channel phase recovery. The results presented demonstrate the system performance under very realistic Nakagami-m fading and additive white Gaussian noise channel. On the other hand, the accuracy of the obtained results is verified through running the simulation under a good confidence interval reliability of 95 %. We see that as the number of simulation runs N increases, the simulated error rate becomes closer to the actual one and the confidence interval difference reduces. Hence our results are expected to be of significant practical use for such scenarios. © 2012 Springer Science+Business Media New York.

  19. Estimation of daily flow rate of photovoltaic water pumping systems using solar radiation data

    Directory of Open Access Journals (Sweden)

    M. Benghanem

    2018-03-01

    Full Text Available This paper presents a simple model which allows us to contribute in the studies of photovoltaic (PV water pumping systems sizing. The nonlinear relation between water flow rate and solar power has been obtained experimentally in a first step and then used for performance prediction. The model proposed enables us to simulate the water flow rate using solar radiation data for different heads (50 m, 60 m, 70 m and 80 m and for 8S × 3P PV array configuration. The experimental data are obtained with our pumping test facility located at Madinah site (Saudi Arabia. The performances are calculated using the measured solar radiation data of different locations in Saudi Arabia. Knowing the solar radiation data, we have estimated with a good precision the water flow rate Q in five locations (Al-Jouf, Solar Village, AL-Ahsa, Madinah and Gizan in Saudi Arabia. The flow rate Q increases with the increase of pump power for different heads following the nonlinear model proposed. Keywords: Photovoltaic water pumping system, Solar radiation data, Simulation, Flow rate

  20. Ammonia and nitrite removal rates in a closed recirculating-water system, under three load rates of rainbow trout Oncorhynchus mykiss

    OpenAIRE

    Arredondo-Figueroa, J. L.; Ingle de la Mora, G; Guerrero-Legarreta, I; Ponce-Palafox, J. T.; Barriga-Sosa, I. de los A.

    2007-01-01

    Nitrification and denitrification rates of inorganic nitrogen were studied in a closed recirculating-water system, comparing three load rates of rainbow trout Oncorhynchus mykiss (89, 156 and 194 kg in each tank with two repetitions). Six self-cleaning water circular fish tanks with a volume of 4.3 m³ were used, maintaining a 3.94 m³/day of average flow rate and constant aeration. A total of 371 rainbow trout, 524 ± 8 g initial wet weight were introduced in the system and fed with a commercia...

  1. An expert system for the quantification of fault rates in construction fall accidents.

    Science.gov (United States)

    Talat Birgonul, M; Dikmen, Irem; Budayan, Cenk; Demirel, Tuncay

    2016-01-01

    Expert witness reports, prepared with the aim of quantifying fault rates among parties, play an important role in a court's final decision. However, conflicting fault rates assigned by different expert witness boards lead to iterative objections raised by the related parties. This unfavorable situation mainly originates due to the subjectivity of expert judgments and unavailability of objective information about the causes of accidents. As a solution to this shortcoming, an expert system based on a rule-based system was developed for the quantification of fault rates in construction fall accidents. The aim of developing DsSafe is decreasing the subjectivity inherent in expert witness reports. Eighty-four inspection reports prepared by the official and authorized inspectors were examined and root causes of construction fall accidents in Turkey were identified. Using this information, an evaluation form was designed and submitted to the experts. Experts were asked to evaluate the importance level of the factors that govern fall accidents and determine the fault rates under different scenarios. Based on expert judgments, a rule-based expert system was developed. The accuracy and reliability of DsSafe were tested with real data as obtained from finalized court cases. DsSafe gives satisfactory results.

  2. Does the Australasian "Health Star Rating" Front of Pack Nutritional Label System Work?

    Science.gov (United States)

    Hamlin, Robert; McNeill, Lisa

    2016-06-01

    This article describes an experiment to measure the impact of the Australasian "Health Star Rating" front of pack nutritional label system on consumer choice behaviour. This system presents a one-half to five star rating of nutritional quality via the front facings of food product packages. While this system has been recently rolled out across Australasia, no test of its impact on food choice has been conducted. A sample of 1200 consumers was recruited on exit from supermarkets in New Zealand. A 2 × 2 factorial design was used with two levels of cold cereal product nutritional status (high, five star/low, two star) and two levels of the Health Star Rating label (present/absent). The dependent variable was revealed choice behaviour. The results indicated that the presence of the label had a significant depressive effect on consumer preference, but that this impact was not moderated in any way by the nutritional status expressed by the label. The result represents a significant functional failure of the Health Star Rating label in this research environment. The nature of the failure is consistent with the consumers processing the label in much the same way as the nominal brand cues that dominate the retail food packaging.

  3. Effect of recirculation rate on methane production and SEBAR system performance using active stage digester.

    Science.gov (United States)

    Tubtong, Cheevanuch; Towprayoon, Sirintornthep; Connor, Michael Anthony; Chaiprasert, Pawinee; Nopharatana, Annop

    2010-09-01

    A project was undertaken to examine the feasibility of treating organic wastes from Thai fruit and vegetable markets using the sequential batch anaerobic digester (SEBAR) approach. A key feature of the SEBAR system is the regular interchanging, or recirculation, of portions of leachate between each freshly filled digester and a support digester to which it is coupled until it is ready to operate independently. Leachate transfer from this support digester to the fresh waste digester provides additional alkalinity to help counteract the effects of early high acid release rates; it also helps build a balanced microbial population in the fresh waste digester. To optimize the leachate recirculation process, the effect of varying the quantities of leachate interchanged between freshly filled waste digesters and the still highly active support digesters to which they were coupled was studied. It was found that increasing the recirculation rate accelerated the onset of both waste degradation and methane production. The increasing of recirculation rate from 10% to 20% and 10% to 30% could reduce the SEBAR cycle period by approximately 7% and 22% without significant reduction in the amount of methane obtained from the systems. The methane yields were 0.0063, 0.0068 and 0.0077 l g(-1) VS added in the NEW digester per day using leachate recirculation rates of 10%, 20% and 30%, respectively. This finding has potentially important practical and economic implications for those using the SEBAR system to add value to market waste.

  4. Direct Load Control (DLC) Considering Nodal Interrupted Energy Assessment Rate (NIEAR) in Restructured Power Systems

    DEFF Research Database (Denmark)

    Wu, Qiuwei; Wang, Peng; Goel, Lalit

    2010-01-01

    is used as the bids from the ACL customers, is utilized to determine the direct monetary compensation to the ACL customers. The proposed scheme was investigated for the PoolCo electricity market. The optimal DLC scheme is determined based on the minimum system operating cost which is comprised......A direct load control (DLC) scheme of air conditioning loads (ACL) considering direct monetary compensation to ACL customers for the service interruption caused by the DLC program is proposed in this paper for restructured power systems. The nodal interrupted energy assessment rate (NIEAR), which...... of the system energy cost, the system spinning reserve cost and the compensation cost to the ACL customers. Dynamic programming (DP) was used to obtain the optimal DLC scheme. The IEEE reliability test system (RTS) was studied to illustrate the proposed DLC scheme....

  5. Pilot States Program report: Home energy ratings systems and energy-efficient mortgages

    Energy Technology Data Exchange (ETDEWEB)

    Farhar, B.

    2000-04-04

    This report covers the accomplishments of the home energy ratings systems/energy-efficient mortgages (HERS/EEMs) pilot states from 1993 through 1998, including such indicators as funding, ratings and EEMs achieved, active raters, and training and marketing activities. A brief description of each HERS program's evolution is included, as well as their directors' views of the programs' future prospects. Finally, an analysis is provided of successful HERS program characteristics and factors that appear to contribute to HERS program success.

  6. Description of the local dose rate measuring system for the Angra 2 nuclear power plant

    International Nuclear Information System (INIS)

    Costa, Lilian Rose Sobral da; Souza Mendes, Jorge Eduardo de

    1995-01-01

    The equipment used and the measured value processing involved in the Local Dose Rate Measuring System is described including the installation points for the measuring equipment in the reactor building, the auxiliary building and at the main gate of Angra 2 Nuclear Power Plant. Under normal operating conditions protecting of the personnel is ensured by measuring the local dose rate at those points which are generally accessible. In some cases , fixed sensors are not suitable so that mobile equipment is used. (author). 2 refs., 1 fig

  7. Urinary albumin and beta 2-microglobulin excretion rates in patients with systemic lupus erythematosus

    DEFF Research Database (Denmark)

    Parving, H H; Sørensen, S F; Mogensen, C E

    1980-01-01

    The daily urinary albumin and beta 2-microglobulin excretion rates were measured with sensitive radioimmunoassays in 14 patients with systemic lupus erythematosus (SLE). The duration of SLE ranged from 0.5 to 18 years, mean 10 years. The mean age was 37 years. All patients except 5 received...... prednisone, 5-20 mg/day. None of the patients had proteinuria as judged by the "Albustix" test, and all had normal serum creatinine. The daily urinary albumin and beta 2-microglobulin excretion rates were nearly the same as those previously found by us in 27 adult control subjects with a mean age of 44 years...

  8. Splitting of the rate matrix as a definition of time reversal in master equation systems

    International Nuclear Information System (INIS)

    Liu Fei; Le, Hong

    2012-01-01

    Motivated by recent progress in nonequilibrium fluctuation relations, we present a generalized time reversal for stochastic master equation systems with discrete states, which is defined as a splitting of the rate matrix into irreversible and reversible parts. An immediate advantage of this definition is that a variety of fluctuation relations can be attributed to different matrix splittings. Additionally, we find that the accustomed total entropy production formula and conditions of the detailed balance must be modified appropriately to account for the reversible rate part, which was previously ignored. (paper)

  9. Achievable Rates of UAV-Relayed Cooperative Cognitive Radio MIMO Systems

    KAUST Repository

    Sboui, Lokman; Ghazzai, Hakim; Rezki, Zouheir; Alouini, Mohamed-Slim

    2017-01-01

    We study the achievable rate of an uplink MIMO cognitive radio system where the primary user (PU) and the secondary user (SU) aim to communicate to the closest primary base station (BS) via a multi-access channel through the same unmanned aerial vehicle (UAV) relay. The SU message is then forwarded from the primary BS to the secondary network with a certain incentive reward as a part of the cooperation protocol between both networks. A special linear precoding scheme is proposed to enable the SU to exploit the PU free eigenmodes. We analyze two scenarios in which the UAV relay gain matrix is either fixed or optimized. We derive the optimal power allocation that maximizes the achievable rate of the SU respecting power budget, interference, and relay power constraints. Numerical results highlight the cognitive rate gain of our proposed scheme with respect to various problem parameters. We also highlight the effect of UAV altitude on the SU and PU rates. Finally, when the relay matrix is optimized, we show that the PU rate is remarkably enhanced and that the SU rate is only improved at high power regime.

  10. Achievable Rates of UAV-Relayed Cooperative Cognitive Radio MIMO Systems

    KAUST Repository

    Sboui, Lokman

    2017-04-19

    We study the achievable rate of an uplink MIMO cognitive radio system where the primary user (PU) and the secondary user (SU) aim to communicate to the closest primary base station (BS) via a multi-access channel through the same unmanned aerial vehicle (UAV) relay. The SU message is then forwarded from the primary BS to the secondary network with a certain incentive reward as a part of the cooperation protocol between both networks. A special linear precoding scheme is proposed to enable the SU to exploit the PU free eigenmodes. We analyze two scenarios in which the UAV relay gain matrix is either fixed or optimized. We derive the optimal power allocation that maximizes the achievable rate of the SU respecting power budget, interference, and relay power constraints. Numerical results highlight the cognitive rate gain of our proposed scheme with respect to various problem parameters. We also highlight the effect of UAV altitude on the SU and PU rates. Finally, when the relay matrix is optimized, we show that the PU rate is remarkably enhanced and that the SU rate is only improved at high power regime.

  11. Mini-review: high rate algal ponds, flexible systems for sustainable wastewater treatment.

    Science.gov (United States)

    Young, P; Taylor, M; Fallowfield, H J

    2017-06-01

    Over the last 20 years, there has been a growing requirement by governments around the world for organisations to adopt more sustainable practices. Wastewater treatment is no exception, with many currently used systems requiring large capital investment, land area and power consumption. High rate algal ponds offer a sustainable, efficient and lower cost option to the systems currently in use. They are shallow, mixed lagoon based systems, which aim to maximise wastewater treatment by creating optimal conditions for algal growth and oxygen production-the key processes which remove nitrogen and organic waste in HRAP systems. This design means they can treat wastewater to an acceptable quality within a fifth of time of other lagoon systems while using 50% less surface area. This smaller land requirement decreases both the construction costs and evaporative water losses, making larger volumes of treated water available for beneficial reuse. They are ideal for rural, peri-urban and remote communities as they require minimum power and little on-site management. This review will address the history of and current trends in high rate algal pond development and application; a comparison of their performance with other systems when treating various wastewaters; and discuss their potential for production of added-value products. Finally, the review will consider areas requiring further research.

  12. Predicting Precession Rates from Secular Dynamics for Extra-solar Multi-planet Systems

    Science.gov (United States)

    Van Laerhoven, Christa

    2015-12-01

    Considering the secular dynamics of multi-planet systems provides substantial insight into the interactions between planets in those systems. Secular interactions are those that don't involve knowing where a planet is along its orbit, and they dominate when planets are not involved in mean motion resonances. These interactions exchange angular momentum among the planets, evolving their eccentricities and inclinations. To second order in the planets' eccentricities and inclinations, the eccentricity and inclination perturbations are decoupled. Given the right variable choice, the relevant differential equations are linear and thus the eccentricity and inclination behaviors can be described as a sum of eigenmodes. Since the underlying structure of the secular eigenmodes can be calculated using only the planets' masses and semi-major axes, one can elucidate the eccentricity and inclination behavior of planets in exoplanet systems even without knowing the planets' current eccentricities and inclinations. I have calculated both the eccentricity and inclination secular eigenmodes for the population of known multi-planet systems whose planets have well determined masses and periods and have used this to predict what range of pericenter precession (and nodal regression) rates the planets may have. One might have assumed that in any given system the planets with shorter periods would have faster precession rates, but I show that this is not necessarily the case. Planets that are 'loners' have narrow ranges of possible precession rates, while planets that are 'groupies' can have a wider range of possible precession rates. Several planets are expected to undergo significant precession on few-year timescales and many planets (though not the majority of planets) will undergo significant precession on decade timescales.

  13. The system for automatic dose rate measurements by mobile groups in field

    International Nuclear Information System (INIS)

    Drabova, D.; Filgas, R.; Cespirova, I.; Ejemova, M.

    1998-01-01

    The comparison of characteristics between a pressurized ionization chamber, plastic scintillator and proportional counter is given. Based on requirements and comparison of properties of various probes, the system for automatic dose rate measurement and integration of geographic co-ordinates in field was designed and tested.The system consists of proportional counter. This is so-called intelligent probe can be easily connected to a personal computer. The probe measures in the energy range 30 keV - 1.3 MeV with reasonable energy and angular response, it can measure the dose rate in the range 50 nSv/h - 1 Sv/h with the typical efficiency 9.5 imp/s/μSv/h. The probe is fixed in the holder placed on the front mask of a car. For the simultaneous determination of geographical co-ordinates the personal GPS navigator Garmin 95 is used. Both devices are controlled by a notebook via two serial ports. The second serial port that is not quite common in notebook can be easily realised by a PCMCIA card. The notebook is used in the field by a mobile group can be transmitted to the assessment centre by the cellular GSM phone. The system Nokia 2110 connected to notebook by PCMCIA card is used. The whole system is powered up from the car battery. The system is controlled by specially developed software. The software was developed in the FoxPro 2.5 environment and works under MS-DOS 6.22. It has no problems to work in Windows 95 DOS window. The results of dose rate measurements obtained during route monitoring are stored in files. They can be displayed on a graphic screen, presenting the geographical distribution of the dose rate values colour coded on a map and the time sequence of the measured data. (authors)

  14. The impact of a supermarket nutrition rating system on purchases of nutritious and less nutritious foods.

    Science.gov (United States)

    Cawley, John; Sweeney, Matthew J; Sobal, Jeffery; Just, David R; Kaiser, Harry M; Schulze, William D; Wethington, Elaine; Wansink, Brian

    2015-01-01

    The current study examines the impact of a nutrition rating system on consumers' food purchases in supermarkets. Aggregate sales data for 102 categories of food (over 60 000 brands) on a weekly basis for 2005-2007 from a supermarket chain of over 150 stores are analysed. Change in weekly sales of nutritious and less nutritious foods, after the introduction of a nutrition rating system on store shelves, is calculated, controlling for seasonality and time trends in sales. One hundred and sixty-eight supermarket stores in the north-east USA, from January 2005 to December 2007. Consumers purchasing goods at the supermarket chain during the study period. After the introduction of the nutrition ratings, overall weekly food sales declined by an average of 3637 units per category (95 % CI -5961, -1313; P<0·01). Sales of less nutritious foods fell by 8·31 % (95 % CI -13·50, -2·80 %; P=0·004), while sales of nutritious foods did not change significantly (P=0·21); as a result, the percentage of food purchases rated as nutritious rose by 1·39 % (95 % CI 0·58, 2·20 %; P<0·01). The decrease in sales of less nutritious foods was greatest in the categories of canned meat and fish, soda pop, bakery and canned vegetables. The introduction of the nutrition ratings led shoppers to buy a more nutritious mix of products. Interestingly, it did so by reducing purchases of less nutritious foods rather than by increasing purchases of nutritious foods. In evaluating nutrition information systems, researchers should focus on the entire market basket, not just sales of nutritious foods.

  15. On the rates of type Ia supernovae originating from white dwarf collisions in quadruple star systems

    Science.gov (United States)

    Hamers, Adrian S.

    2018-04-01

    We consider the evolution of stellar hierarchical quadruple systems in the 2+2 (two binaries orbiting each other's barycentre) and 3+1 (triple orbited by a fourth star) configurations. In our simulations, we take into account the effects of secular dynamical evolution, stellar evolution, tidal evolution and encounters with passing stars. We focus on type Ia supernovae (SNe Ia) driven by collisions of carbon-oxygen (CO) white dwarfs (WDs). Such collisions can arise from several channels: (1) collisions due to extremely high eccentricities induced by secular evolution, (2) collisions following a dynamical instability of the system, and (3) collisions driven by semisecular evolution. The systems considered here have initially wide inner orbits, with initial semilatus recti larger than 12 {au}, implying no interaction if the orbits were isolated. However, taking into account dynamical evolution, we find that ≈0.4 (≈0.6) of 2+2 (3+1) systems interact. In particular, Roche Lobe overflow can be triggered possibly in highly eccentric orbits, dynamical instability can ensue due to mass-loss-driven orbital expansion or secular evolution, or a semisecular regime can be entered. We compute the delay-time distributions (DTDs) of collision-induced SNe Ia, and find that they are flatter compared to the observed DTD. Moreover, our combined SNe Ia rates are (3.7± 0.7) × 10^{-6} M_⊙^{-1} and (1.3± 0.2) × 10^{-6} M_⊙^{-1} for 2+2 and 3+1 systems, respectively, three orders of magnitude lower compared to the observed rate, of order 10^{-3} M_⊙^{-1}. The low rates can be ascribed to interactions before the stars evolve to CO WDs. However, our results are lower limits given that we considered a subset of quadruple systems.

  16. Adaptive sampling rate control for networked systems based on statistical characteristics of packet disordering.

    Science.gov (United States)

    Li, Jin-Na; Er, Meng-Joo; Tan, Yen-Kheng; Yu, Hai-Bin; Zeng, Peng

    2015-09-01

    This paper investigates an adaptive sampling rate control scheme for networked control systems (NCSs) subject to packet disordering. The main objectives of the proposed scheme are (a) to avoid heavy packet disordering existing in communication networks and (b) to stabilize NCSs with packet disordering, transmission delay and packet loss. First, a novel sampling rate control algorithm based on statistical characteristics of disordering entropy is proposed; secondly, an augmented closed-loop NCS that consists of a plant, a sampler and a state-feedback controller is transformed into an uncertain and stochastic system, which facilitates the controller design. Then, a sufficient condition for stochastic stability in terms of Linear Matrix Inequalities (LMIs) is given. Moreover, an adaptive tracking controller is designed such that the sampling period tracks a desired sampling period, which represents a significant contribution. Finally, experimental results are given to illustrate the effectiveness and advantages of the proposed scheme. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  17. Exploiting Rating Abstention Intervals for Addressing Concept Drift in Social Network Recommender Systems

    Directory of Open Access Journals (Sweden)

    Dionisis Margaris

    2018-04-01

    Full Text Available One of the major problems that social networks face is the continuous production of successful, user-targeted information in the form of recommendations, which are produced exploiting technology from the field of recommender systems. Recommender systems are based on information about users’ past behavior to formulate recommendations about their future actions. However, as time goes by, social network users may change preferences and likings: they may like different types of clothes, listen to different singers or even different genres of music and so on. This phenomenon has been termed as concept drift. In this paper: (1 we establish that when a social network user abstains from rating submission for a long time, it is a strong indication that concept drift has occurred and (2 we present a technique that exploits the abstention interval concept, to drop from the database ratings that do not reflect the current social network user’s interests, thus improving prediction quality.

  18. Measurement of infiltration rates in urban sewer systems by use of oxygen isotopes.

    Science.gov (United States)

    De Bénédittis, J; Bertrand-Krajewski, J L

    2005-01-01

    The paper presents the principle of a method to measure infiltration rates in sewer systems based on the use of oxygen isotopes and its application in Lyon (France). In the urban area of Lyon, significant differences in delta 18O that can reach 3 per thousand are observed between the oxygen isotopic compositions of groundwater originating from Rhone, Saone and from their associated alluvial aquifers. Drinking water supplying Lyon results mainly from pumping in the Rhone alluvial aquifer. Therefore, in some areas, the difference of isotopic composition between wastewater resulting from the consumption of drinking water and local groundwater can be used to measure infiltration in sewer systems. The application in the catchment of Ecully shows that the infiltration flow rate presents strong fluctuations at an hourly scale: it varies between 15 and 40 m3/h. This variability could be explained by non-constant discharges of pumping and by variations of the water level in the sewer.

  19. Recursive Estimation for Dynamical Systems with Different Delay Rates Sensor Network and Autocorrelated Process Noises

    Directory of Open Access Journals (Sweden)

    Jianxin Feng

    2014-01-01

    Full Text Available The recursive estimation problem is studied for a class of uncertain dynamical systems with different delay rates sensor network and autocorrelated process noises. The process noises are assumed to be autocorrelated across time and the autocorrelation property is described by the covariances between different time instants. The system model under consideration is subject to multiplicative noises or stochastic uncertainties. The sensor delay phenomenon occurs in a random way and each sensor in the sensor network has an individual delay rate which is characterized by a binary switching sequence obeying a conditional probability distribution. By using the orthogonal projection theorem and an innovation analysis approach, the desired recursive robust estimators including recursive robust filter, predictor, and smoother are obtained. Simulation results are provided to demonstrate the effectiveness of the proposed approaches.

  20. Design and optimization of a large flow rate booster pump in SWRO energy recovery system

    International Nuclear Information System (INIS)

    Lai, Z N; Wu, P; Wu, D Z; Wang, L Q

    2013-01-01

    Seawater reverse osmosis (SWRO) is a high energy-consumption industry, so energy efficiency is an important issue. Energy recovery systems, which contain a pressure exchanger and a booster pump, are widely used in SWRO plants. As a key part of energy recovery system, the difficulty of designing booster pumps lies in high inlet pressure, high medium causticity and large flow rate. High inlet pressure adds difficulties to seal design, and large flow rate and high efficiency requirement bring high demand for hydraulic design. In this paper, a 625 m 3 /h booster pump is designed and optimized according to the CFD (Computational Fluid Dynamics) simulation results. The impeller and volute is well designed, a new type of high pressure mechanical seal is applied and axial force is well balanced. After optimization based on blade redesign, the efficiency of the pump was improved. The best efficiency reaches more than 85% at design point according to the CFD simulation result

  1. Design and optimization of a large flow rate booster pump in SWRO energy recovery system

    Science.gov (United States)

    Lai, Z. N.; Wu, P.; Wu, D. Z.; Wang, L. Q.

    2013-12-01

    Seawater reverse osmosis (SWRO) is a high energy-consumption industry, so energy efficiency is an important issue. Energy recovery systems, which contain a pressure exchanger and a booster pump, are widely used in SWRO plants. As a key part of energy recovery system, the difficulty of designing booster pumps lies in high inlet pressure, high medium causticity and large flow rate. High inlet pressure adds difficulties to seal design, and large flow rate and high efficiency requirement bring high demand for hydraulic design. In this paper, a 625 m3/h booster pump is designed and optimized according to the CFD (Computational Fluid Dynamics) simulation results. The impeller and volute is well designed, a new type of high pressure mechanical seal is applied and axial force is well balanced. After optimization based on blade redesign, the efficiency of the pump was improved. The best efficiency reaches more than 85% at design point according to the CFD simulation result.

  2. Transmission Characteristics of an OFDM signal for Power Line Communication System with High Bit Rate

    Science.gov (United States)

    Mori, Akira; Watanabe, Yosuke; Tokuda, Masamitsu; Kawamoto, Koji

    In this paper, we measured what influence the sinusoidal transmission characteristics of the electric power line with various forms gave to the transmission characteristic of OFDM (Orthogonal Frequency Division Multiplexing) signal through PLC (power line communication system) modem. We classified the electric power line transmission line with various forms in a real environment into two basic elements, which are an outlet type branch and a switch type branch. Next, PHY rate (Physical rate) is measured for each basic element connected with the PLC modem. At this time, the transmission characteristics of the electric power line are simulated from measured data. OFDM sending and receiving systems are composed on the computer, and the PHY rate is simulated. By comparing with measured and calculated values, it is revealed that PHY rate of PLC modem is most affected in the case of the power line transmission characteristics having broad band and high level attenuation and group delay variation, and is not affected in the case of that having narrow band attenuation and group delay variation.

  3. A study on the achievable data rate in massive MIMO system

    Science.gov (United States)

    Salh, Adeeb; Audah, Lukman; Shah, Nor Shahida M.; Hamzah, Shipun A.

    2017-09-01

    The achievable high data rates depend on the ability of massive multi-input-multi-output (MIMO) for the fifth-generation (5G) cellular networks, where the massive MIMO systems can support very high energy and spectral efficiencies. A major challenge in mobile broadband networks is how to support the throughput in the future 5G, where the highlight of 5G expected to provide high speed internet for every user. The performance massive MIMO system increase with linear minimum mean square error (MMSE), zero forcing (ZF) and maximum ratio transmission (MRT) when the number of antennas increases to infinity, by deriving the closed-form approximation for achievable data rate expressions. Meanwhile, the high signal-to-noise ratio (SNR) can be mitigated by using MMSE, ZF and MRT, which are used to suppress the inter-cell interference signals between neighboring cells. The achievable sum rate for MMSE is improved based on the distributed users inside cell, mitigated the inter-cell interference caused when send the same signal by other cells. By contrast, MMSE is better than ZF in perfect channel state information (CSI) for approximately 20% of the achievable sum rate.

  4. Linking mortgage finance incentives to a voluntary home energy rating system: Insight into consensus building

    International Nuclear Information System (INIS)

    Jenior, M.-M.

    1994-01-01

    A collaborative consensus process was created to implement a program linking voluntary home energy rating systems (HERS) to mortgage incentives. The participants involved many of the stakeholders or interest groups who have a role in implementing and who will be affected by energy efficiency mortgate incentive programs linked to HERS. The participants included representatives from the primary and secondary mortgage market; real estate, home building, and remodeling industries; utilities; state, local, consumer, and environmental organizations; and home energy rating providers. The participants defined the actions required to implement as well as the technical requirements of a program linking home energy ratings and mortgage finance. Building on the recommendations of the collaborative process, members of the collaborative continue to take initiatives to put a Home Energy Rating Systems Council into place, in planning pilot programs for developing and testing ways to link HERS and mortgage programs, and in making home buyers and owners aware of existing mortgage incentives. At the same time, mortgage providers are working to develop uniformity among mortgage incentive programs and with the US Department of Energy to develop procedures to verify the relative accuracy of HERS calculation tools and their application, and with the emerging HERS Council to develop the guidelines for voluntary HERS required under the Energy Policy Act of 1992

  5. Evaluation of mean time between forced outage for reactor protection system using RBD and failure rate

    International Nuclear Information System (INIS)

    Lee, D. Y.; Park, J. H.; Hwang, I. K.; Cha, K. H.; Choi, J. K.; Lee, K. Y.; Park, J. K.

    2001-01-01

    The design life of nuclear power plants (NPPs) under recent construction is about fifty to sixty years. However, the duration that equipments of control systems operate without failures is at most five to ten years. Design for diversity and adequate maintenance strategy are required for NPP protection system in order to use the control equipment which has shorter life time than the design life of NPP. Fault Tree Analysis (FTA) technique, which has been applied to Probabilistics Safety Analysis (PSA), has been introduced to quantitatively evaluate the reliability of NPP I and C systems. The FTA, however, cannot properly consider the effect of maintenance. In this work, we have reviewed quantitative reliability evaluation techniques using the reliability block diagram and failure rates and applied it to the evaluation of mean time between forced outage for reactor protection system

  6. Contact dose rates and relevant radioactive inventory in ITER TBM systems

    International Nuclear Information System (INIS)

    Zucchetti, M.; Guerrini, L.; Poitevin, Y.; Ricapito, I.; Zmitko, M.

    2011-01-01

    The determination of the radioactive inventory and of the contact dose rates in the different ITER Test Blanket Modules systems is carried out, both for Helium-Cooled Lithium-Lead (HCLL) concept and the Helium-Cooled Pebble-Bed (HCPB) concept. The evaluations have been carried out by means of the MICROSHIELD code, starting from the data on the neutron-induced radioactivity in the blanket materials, already available for both the blanket modules. The possible sources of radioactive material in all the systems have been individuated and their contributes estimated.

  7. Contact dose rates and relevant radioactive inventory in ITER TBM systems

    Energy Technology Data Exchange (ETDEWEB)

    Zucchetti, M., E-mail: massimo.zucchetti@polito.it [EURATOM/ENEA Fusion Association Politecnico di Torino, Torino (Italy); Guerrini, L., E-mail: Laurent.Guerrini@f4e.europa.eu [Fusion for Energy, ITER Department, Test Blanket Modules Group, Barcelona (Spain); Poitevin, Y.; Ricapito, I.; Zmitko, M. [Fusion for Energy, ITER Department, Test Blanket Modules Group, Barcelona (Spain)

    2011-10-15

    The determination of the radioactive inventory and of the contact dose rates in the different ITER Test Blanket Modules systems is carried out, both for Helium-Cooled Lithium-Lead (HCLL) concept and the Helium-Cooled Pebble-Bed (HCPB) concept. The evaluations have been carried out by means of the MICROSHIELD code, starting from the data on the neutron-induced radioactivity in the blanket materials, already available for both the blanket modules. The possible sources of radioactive material in all the systems have been individuated and their contributes estimated.

  8. Preliminary Calculations of Shutdown Dose Rate for the CTS Diagnostics System

    DEFF Research Database (Denmark)

    Klinkby, Esben Bryndt; Nonbøl, Erik; Lauritzen, Bent

    2015-01-01

    DTU and IST 2 are partners in the design of a collective Thomson Scattering (CTS) diagnostics for ITER through a contract with F4E. The CTS diagnostic utilizes probing radiation of ~60 GHz emitted into the plasma and, using a mirror, collects the scattered radiation by an array of receivers. Having...... on supplying input which affect the system design. Examples include: - Heatloads on plasma facing mirrors and preliminary stress and thermal analysis - Port plug cooling requirements and it's dependence on system design (in particular blanket cut-out) - Shutdown dose-rate calculations (relative analysis...

  9. A Longitudinal Study and Color Rating System of Acquisition Cost Growth

    Science.gov (United States)

    2017-03-23

    cost growth analysis. Ways in which this research can be carried forward include: • Collect more SAR data to further populate our research database... Growth Cory N. D’Amico Follow this and additional works at: https://scholar.afit.edu/etd Part of the Finance and Financial Management Commons This...and Color Rating System of Acquisition Cost Growth " (2017). Theses and Dissertations. 781. https://scholar.afit.edu/etd/781 A Longitudinal

  10. Rates and patterns of deforestation in the Philippines: application of geographic information system analysis

    Science.gov (United States)

    Dawning S. Lui; Louis R. Iverson; Sandra Brown

    1993-01-01

    Land-use maps for 1934 and 1988, and a 1941 road map of the Philippines were digitized into a geographic information system. These maps were then analyzed to determine the rates of deforestation and their relationship with factors such as the distance of forests to roads and forest fragmentation (measured by perimeter-to-area ratio (P/A ratio) of forest patches) for...

  11. PBODL : Parallel Bayesian Online Deep Learning for Click-Through Rate Prediction in Tencent Advertising System

    OpenAIRE

    Liu, Xun; Xue, Wei; Xiao, Lei; Zhang, Bo

    2017-01-01

    We describe a parallel bayesian online deep learning framework (PBODL) for click-through rate (CTR) prediction within today's Tencent advertising system, which provides quick and accurate learning of user preferences. We first explain the framework with a deep probit regression model, which is trained with probabilistic back-propagation in the mode of assumed Gaussian density filtering. Then we extend the model family to a variety of bayesian online models with increasing feature embedding ca...

  12. Reliability prediction system based on the failure rate model for electronic components

    International Nuclear Information System (INIS)

    Lee, Seung Woo; Lee, Hwa Ki

    2008-01-01

    Although many methodologies for predicting the reliability of electronic components have been developed, their reliability might be subjective according to a particular set of circumstances, and therefore it is not easy to quantify their reliability. Among the reliability prediction methods are the statistical analysis based method, the similarity analysis method based on an external failure rate database, and the method based on the physics-of-failure model. In this study, we developed a system by which the reliability of electronic components can be predicted by creating a system for the statistical analysis method of predicting reliability most easily. The failure rate models that were applied are MILHDBK- 217F N2, PRISM, and Telcordia (Bellcore), and these were compared with the general purpose system in order to validate the effectiveness of the developed system. Being able to predict the reliability of electronic components from the stage of design, the system that we have developed is expected to contribute to enhancing the reliability of electronic components

  13. Are US utility standby rates inhibiting diffusion of customer-owned generating systems?

    International Nuclear Information System (INIS)

    Jackson, Jerry

    2007-01-01

    New, small-scale electric generation technologies permit utility customers to generate some of their own electric power and to utilize waste heat for space heating and other applications at the building site. This combined heat and power (CHP) characteristic can provide significant energy-cost savings. However, most current US utility regulations leave CHP standby rate specification largely to utility discretion resulting in claims by CHP advocates that excessive standby rates are significantly reducing CHP-related savings and inhibiting CHP diffusion. The impacts of standby rates on the adoption of CHP are difficult to determine; however, because of the characteristically slow nature of new technology diffusion. This study develops an agent-based microsimulation model of CHP technology choice using cellular automata to represent new technology information dispersion and knowledge acquisition. Applying the model as an n-factorial experiment quantifies the impacts of standby rates on CHP technologies under alternative diffusion paths. Analysis of a sample utility indicates that, regardless of the likely diffusion process, reducing standby rates to reflect the cost of serving a large number of small, spatially clustered CHP systems significantly increases the adoption of these technologies

  14. A study on the optimal hydraulic loading rate and plant ratios in recirculation aquaponic system.

    Science.gov (United States)

    Endut, Azizah; Jusoh, A; Ali, N; Wan Nik, W B; Hassan, A

    2010-03-01

    The growths of the African catfish (Clarias gariepinus) and water spinach (Ipomoea aquatica) were evaluated in recirculation aquaponic system (RAS). Fish production performance, plant growth and nutrient removal were measured and their dependence on hydraulic loading rate (HLR) was assessed. Fish production did not differ significantly between hydraulic loading rates. In contrast to the fish production, the water spinach yield was significantly higher in the lower hydraulic loading rate. Fish production, plant growth and percentage nutrient removal were highest at hydraulic loading rate of 1.28 m/day. The ratio of fish to plant production has been calculated to balance nutrient generation from fish with nutrient removal by plants and the optimum ratio was 15-42 gram of fish feed/m(2) of plant growing area. Each unit in RAS was evaluated in terms of oxygen demand. Using specified feeding regime, mass balance equations were applied to quantify the waste discharges from rearing tanks and treatment units. The waste discharged was found to be strongly dependent on hydraulic loading rate. 2009 Elsevier Ltd. All rights reserved.

  15. Optimizing contaminant desorption and bioavailability in dense slurry systems. 2. PAH bioavailability and rates of degradation.

    Science.gov (United States)

    Kim, Han S; Weber, Walter J

    2005-04-01

    The effects of mechanical mixing on rates of polycyclic aromatic hydrocarbon (PAH) biodegradation in dense geosorbent slurry (67% solids content, w/w) systems were evaluated using laboratory-scale intermittently mixed batch bioreactors. A PAH-contaminated soil and a phenanthrene-sorbed mineral sorbent (alpha-Al2O3) were respectively employed as slurry solids in aerobic and anaerobic biodegradation studies. Both slurries exhibited a characteristic behavior of pseudoplastic non-Newtonian fluids, and the impeller revolution rate and its diameter had dramatic impacts on power and torque requirements in their laminar flow mixing. Rates of phenanthrene biodegradation were markedly enhanced by relatively low-level auger mixing under both aerobic and anaerobic (denitrifying) conditions. Parameters for empirical models correlating biodegradation rate coefficient (k(b)) values to the degree of mixing were similar to those for correlations between mass transfer (desorption) rate coefficient (k(r)) values for rapidly desorbing fractions of soil organic matter and degree of mixing reported in a companion study, supporting a conclusion that performance-efficient and cost-effective enhancements of PAH mass transfer (desorption) and its biodegradation processes can be achieved by the introduction of optimal levels of reactor-scale mechanical mixing.

  16. Achievable rate of spectrum sharing cognitive radio systems over fading channels at low-power regime

    KAUST Repository

    Sboui, Lokman

    2014-11-01

    We study the achievable rate of cognitive radio (CR) spectrum sharing systems at the low-power regime for general fading channels and then for Nakagami fading. We formally define the low-power regime and present the corresponding closed-form expressions of the achievable rate lower bound under various types of interference and/or power constraints, depending on the available channel state information of the cross link (CL) between the secondary-user transmitter and the primary-user receiver. We explicitly characterize two regimes where either the interference constraint or the power constraint dictates the optimal power profile. Our framework also highlights the effects of different fading parameters on the secondary link (SL) ergodic achievable rate. We also study more realistic scenarios when there is either 1-bit quantized channel feedback from the CL alone or 2-bit feedback from both the CL and the SL and propose simple power control schemes and show that these schemes achieve the previously achieved rate at the low-power regime. Interestingly, we show that the low-power regime analysis provides a specific insight into the maximum achievable rate behavior of CR that has not been reported by previous studies.

  17. Systems and rates of aerial application of fungicides in irrigated rice

    Directory of Open Access Journals (Sweden)

    Tânia Bayer

    Full Text Available ABSTRACT The present research studied the performance of flat-fan and hollow-cone nozzles, with application rates of 20 and 30 L ha-1, and rotary disc atomizer with application rates of 10 and 15 L ha-1. The test was conducted with a fungicide spray tank composed of Azoxystrobin + Difenoconazole, in which the density and penetration of droplets into the canopy were evaluated using a water-sensitive paper and the distribution of the active ingredients in the plant was evaluated through the chromatographic analysis. Higher application rates resulted in higher droplet density in the upper stratum of plants. In all treatments, the penetration of the droplets was 26% into the middle stratum and 23% into the lower stratum, in relation to the top of the crop, resulting in an average 25% penetration of droplets into the leaf canopy. The active ingredients were distributed in greater quantity in the upper stratum of the plant. For the same weight, the upper part of the ‘Puitá Inta CL’ rice cultivar has a leaf area 6.4 times larger than the lower part. It was concluded that higher application rate leads to higher droplet density in the upper stratum of the leaf canopy and that all systems and application rates promoted similar penetration of droplets into the canopy.

  18. Study (Prediction of Main Pipes Break Rates in Water Distribution Systems Using Intelligent and Regression Methods

    Directory of Open Access Journals (Sweden)

    Massoud Tabesh

    2011-07-01

    Full Text Available Optimum operation of water distribution networks is one of the priorities of sustainable development of water resources, considering the issues of increasing efficiency and decreasing the water losses. One of the key subjects in optimum operational management of water distribution systems is preparing rehabilitation and replacement schemes, prediction of pipes break rate and evaluation of their reliability. Several approaches have been presented in recent years regarding prediction of pipe failure rates which each one requires especial data sets. Deterministic models based on age and deterministic multi variables and stochastic group modeling are examples of the solutions which relate pipe break rates to parameters like age, material and diameters. In this paper besides the mentioned parameters, more factors such as pipe depth and hydraulic pressures are considered as well. Then using multi variable regression method, intelligent approaches (Artificial neural network and neuro fuzzy models and Evolutionary polynomial Regression method (EPR pipe burst rate are predicted. To evaluate the results of different approaches, a case study is carried out in a part ofMashhadwater distribution network. The results show the capability and advantages of ANN and EPR methods to predict pipe break rates, in comparison with neuro fuzzy and multi-variable regression methods.

  19. A Flow Rate Control Approach on Off-Design Analysis of an Organic Rankine Cycle System

    Directory of Open Access Journals (Sweden)

    Ben-Ran Fu

    2016-09-01

    Full Text Available This study explored effects of off-design heat source temperature (TW,in or flow rate (mW on heat transfer characteristics and performance of an organic Rankine cycle system by controlling the flow rate of working fluid R245fa (i.e., the operation flow rate of R245fa was controlled to ensure that R245fa reached saturation liquid and vapor states at the outlets of the preheater and evaporator, respectively. The results showed that the operation flow rate of R245fa increased with TW,in or mW; higher TW,in or mW yielded better heat transfer performance of the designed preheater and required higher heat capacity of the evaporator; heat transfer characteristics of preheater and evaporator differed for off-design TW,in and mW; and net power output increased with TW,in or mW. The results further indicated that the control strategy should be different for various off-design conditions. Regarding maximum net power output, the flow rate control approach is optimal when TW,in or mW exceeds the design point, but the pressure control approach is better when TW,in or mW is lower than the design point.

  20. Development of computerized dose planning system and applicator for high dose rate remote afterloading irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, T. J. [Keimyung Univ., Taegu (Korea); Kim, S. W. [Fatima Hospital, Taegu (Korea); Kim, O. B.; Lee, H. J.; Won, C. H. [Keimyung Univ., Taegu (Korea); Yoon, S. M. [Dong-a Univ., Pusan (Korea)

    2000-04-01

    To design and fabricate of the high dose rate source and applicators which are tandem, ovoids and colpostat for OB/Gyn brachytherapy includes the computerized dose planning system. Designed the high dose rate Ir-192 source with nuclide atomic power irradiation and investigated the dose characteristics of fabricated brachysource. We performed the effect of self-absorption and determining the gamma constant and output factor and determined the apparent activity of designed source. he automated computer planning system provided the 2D distribution and 3D includes analysis programs. Created the high dose rate source Ir-192, 10 Ci(370GBq). The effective attenuation factor from the self-absorption and source wall was examined to 0.55 of the activity of bare source and this factor is useful for determination of the apparent activity and gamma constant 4.69 Rcm{sup 2}/mCi-hr. Fabricated the colpostat was investigated the dose distributions of frontal, axial and sagittal plane in intra-cavitary radiation therapy for cervical cancer. The reduce dose at bladder and rectum area was found about 20 % of original dose. The computerized brachytherapy planning system provides the 2-dimensional isodose and 3-D include the dose-volume histogram(DVH) with graphic-user-interface mode. emoted afterloading device was built for experiment of created Ir-192 source with film dosimetry within {+-}1 mm discrepancy. 34 refs., 25 figs., 11 tabs. (Author)

  1. Quantitative measurement and visualization of biofilm O 2 consumption rates in membrane filtration systems

    KAUST Repository

    Prest, Emmanuelle I E C

    2012-03-01

    There is a strong need for techniques enabling direct assessment of biological activity of biofouling in membrane filtration systems. Here we present a new quantitative and non-destructive method for mapping O 2 dynamics in biofilms during biofouling studies in membrane fouling simulators (MFS). Transparent planar O 2 optodes in combination with a luminescence lifetime imaging system were used to map the two-dimensional distribution of O 2 concentrations and consumption rates inside the MFS. The O 2 distribution was indicative for biofilm development. Biofilm activity was characterized by imaging of O 2 consumption rates, where low and high activity areas could be clearly distinguished. The spatial development of O 2 consumption rates, flow channels and stagnant areas could be determined. This can be used for studies on concentration polarization, i.e. salt accumulation at the membrane surface resulting in increased salt passage and reduced water flux. The new optode-based O 2 imaging technique applied to MFS allows non-destructive and spatially resolved quantitative biological activity measurements (BAM) for on-site biofouling diagnosis and laboratory studies. The following set of complementary tools is now available to study development and control of biofouling in membrane systems: (i) MFS, (ii) sensitive pressure drop measurement, (iii) magnetic resonance imaging, (iv) numerical modelling, and (v) biological activity measurement based on O 2 imaging methodology. © 2011 Elsevier B.V.

  2. Morbidity rate of nervous system among medical personnel occupationally exposed to chronic low dose irradiation

    International Nuclear Information System (INIS)

    Jonkova, A.

    1987-01-01

    The morbidity rate of the nervous system among 1190 subjects, medical personnel, working with sources and environment of ionizing radiation was studied by the personal analysis of the diseases, written down in the personal out-patient department cards as well as of a control group of 870 medical workers of various other specialities. The morbidity rate of the nervous system among the medical personnel, exposed to chronic occupational radiation effect, was established not to be higher than that of the other medical workers - 38.0 and 40.3% respectively. Neuroses and peripheral nervous diseases have the greatest relative share in the structure of morbidity rate of the nervous system in both groups examined, with no statistical significance in the differences of the indices. The significantly higher incidence of autonome dystonias, established among the personnel from the X-ray departments and consulting rooms could be discussed in connection with the great relative share of the subjects from that group with a length of service over 15 years and had received the possible maximum cumulative equivalent doses. 3 tabs., 21 refs

  3. Development of X-ray CCD camera system with high readout rate using ASIC

    International Nuclear Information System (INIS)

    Nakajima, Hiroshi; Matsuura, Daisuke; Anabuki, Naohisa; Miyata, Emi; Tsunemi, Hiroshi; Doty, John P.; Ikeda, Hirokazu; Katayama, Haruyoshi

    2009-01-01

    We report on the development of an X-ray charge-coupled device (CCD) camera system with high readout rate using application-specific integrated circuit (ASIC) and Camera Link standard. The distinctive ΔΣ type analog-to-digital converter is introduced into the chip to achieve effective noise shaping and to obtain a high resolution with relatively simple circuits. The unit test proved moderately low equivalent input noise of 70μV with a high readout pixel rate of 625 kHz, while the entire chip consumes only 100 mW. The Camera Link standard was applied for the connectivity between the camera system and frame grabbers. In the initial test of the whole system, we adopted a P-channel CCD with a thick depletion layer developed for X-ray CCD camera onboard the next Japanese X-ray astronomical satellite. The characteristic X-rays from 109 Cd were successfully read out resulting in the energy resolution of 379(±7)eV (FWHM) at 22.1 keV, that is, ΔE/E=1.7% with a readout rate of 44 kHz.

  4. Development of the Japanese Version of the Leeds Assessment of the Neuropathic Symptoms and Signs Pain Scale: Diagnostic Utility in a Clinical Setting.

    Science.gov (United States)

    Isomura, Tatsuya; Sumitani, Masahiko; Matsudaira, Ko; Kawaguchi, Mika; Inoue, Reo; Hozumi, Jun; Tanaka, Takeyuki; Oshima, Hirofumi; Mori, Kanto; Taketomi, Shuji; Inui, Hiroshi; Tahara, Keitaro; Yamagami, Ryota; Hayakawa, Kazuhiro

    2017-07-01

    We aimed to assess the diagnostic utility of the linguistically validated Japanese version of the Leeds Assessment of Neuropathic Symptoms and Signs Pain Scale (LANSS-J) as a screening tool for neuropathic pain in the clinical setting. Patients with neuropathic pain or nociceptive pain who were 20 to 85 years of age were included. Sensitivity and specificity using the original cutoff value of 12 were assessed to evaluate the diagnostic utility of the LANSS-J. Sensitivity and specificity with possible cutoff values were calculated, along with area under the receiver operating characteristic curve. We then evaluated agreement regarding assessment of the LANSS-J by two investigators. We used the intraclass correlation coefficient (ICC) for the total score and Cohen's kappa coefficient for each item. Data for patients with neuropathic pain (n = 30) and those with nociceptive pain (n = 29) were analyzed. With a cutoff of 12, the sensitivity was 63.3% (19/30) and the specificity 93.1% (27/29). Sensitivity improved substantially with a cutoff of ≤ 11 (≥ 83.3%, 25/30). High specificity (93.1%, 27/29) was sustained with a cutoff of 9 to 12. The ICC for the total score was 0.85, indicating sufficient agreement. Kappa coefficients ranged from 0.68 to 0.84. The LANSS-J is a valid screening tool for detecting neuropathic pain. Our results suggest that employing the original cutoff value provides high specificity, although a lower cutoff value of 10 or 11 (with its high specificity maintained) may be more beneficial when pain attributed to neuropathic mechanisms is suspected in Japanese patients. © 2016 World Institute of Pain.

  5. Validation of the Malayalam version of Leeds assessment of neuropathic symptoms and signs pain scale in cancer patients in the Regional Cancer Centre, Thiruvananthapuram, Kerala, India

    Directory of Open Access Journals (Sweden)

    Shoukkathali Anzar

    2017-01-01

    Full Text Available Objective: The Self-administered Leeds Assessment of Neuropathic Symptoms and Signs (S-LANSS is a 7-item self-report scale developed to identify pain which is of predominantly neuropathic origin. The aim of this study was to develop a Malayalam version of the LANSS and to test its validity and reliability in chronic pain patients. Methodology: We enrolled 101 Malayalam-speaking chronic pain patients who visited the Division of Palliative Medicine, Regional Cancer Centre, Thiruvananthapuram, Kerala, India. The translated version of S- LANSS was constructed by standard means. Fifty-one neuropathic pain and fifty nociceptive pain patients were identified by an independent pain physician and were subjected to the new pain scale by a palliative care nurse who was blinded to the diagnosis. The “gold standard diagnosis” is what the physician makes after clinical examination. Its validation, sensitivity, specificity, and positive and negative predictive values were determined. Results: Fifty-one neuropathic pain and fifty nociceptive pain patients were subjected to the Malayalam version of S-LANSS pain scale for validity testing. The agreement by Cohen's Kappa 0.743, Chi-square test P < 0.001, sensitivity 89.58, specificity 84.91, positive predictive value 84.31, negative predictive value 90.00, accuracy by 87.13, and likelihood ratio 5.94. Conclusion: The Malayalam version of S-LANSS pain scale is a validated screening tool for identifying neuropathic pain in chronic pain patients in Malayalam-speaking regions.

  6. Nature of rate-limiting steps in a compartmentalized enzyme system. Quantitation of dopamine transport and hydroxylation rates in resealed chromaffin granule ghosts

    International Nuclear Information System (INIS)

    Ahn, N.G.; Klinman, J.P.

    1989-01-01

    Using isolated chromaffin granule ghosts from bovine adrenal medullae, we have studied the kinetics of dopamine beta-monooxygenase (D beta M) activity as it is linked to dopamine transport. Measurements of the initial rates of transport and of transport-linked norepinephrine formation suggested that enzyme activity may be partially rate-limiting in the coupled carrier/enzyme system. This was confirmed by (i) measurements of initial rates of norepinephrine formation using deuterated substrate, which gave isotope effects greater than 2.0, and (ii) kinetic measurements using ghosts pulsed with varying concentrations of labeled dopamine, which indicated substantial substrate accumulation in the vesicle interior as a function of time. Initial rates of product formation, when combined with approximations of internal substrate concentrations, allowed estimates of Kcat and Km for intravesicular D beta M. Activation by external reductant was apparent in both initial rate parameters and the measurements of transients. Under conditions of optimal D beta M activity, the enzyme rate parameters (kcat = 0.31 nmol/s.mg and Km = 2 mM) indicated partial rate limitation compared to dopamine transport (kcat = 0.38 nmol/s.mg and Km = 32 microM). Compartmental analysis of the time curves, performed using numerical nonlinear least squares methods, gave least squares estimates of rate constants for a simple carrier mechanism and kcat values for D beta M which were consistent with estimates from initial rates

  7. 46 CFR 108.437 - Pipe sizes and discharge rates for enclosed ventilation systems for rotating electrical equipment.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Pipe sizes and discharge rates for enclosed ventilation systems for rotating electrical equipment. 108.437 Section 108.437 Shipping COAST GUARD, DEPARTMENT OF... Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.437 Pipe sizes and discharge rates for...

  8. Development of master slave system for interventional radiology with force-rate control

    International Nuclear Information System (INIS)

    Ide, Masaru; Zobel, P.B.; Claudio, P.D.; Mohri, Makoto; Komeda, Takashi

    2010-01-01

    The objective of this study is to develop a master-slave system for a catheter-guided operation, which is performed by using radiology, through the vascular system. When the master-slave system is used, the surgeon is not exposed to x-rays during the operation. The master tool is managed by an operator away from the slave tool, which is near the patient. The system must provide a realistic picture to the surgeon, particularly in term of force information because this operation is performed by observing three-dimensional fields on a two-dimensional monitor. In this paper, we describe the development of a master slave system that involves the use of force-rate control for guiding the catheter without using force sensors. The master tool has a force-display function. This system can be controlled by force and velocity controlling; hence, this system realized an innovative mechanism and algorism. Finally, the preliminary experiment indicated that the new control method was effective. Further, the force display was stable and achieved fast response. (author)

  9. Determination of photoformation rates and scavenging rate constants of hydroxyl radicals in natural waters using an automatic light irradiation and injection system

    International Nuclear Information System (INIS)

    Nakatani, Nobutake; Hashimoto, Norichika; Shindo, Hirotaka; Yamamoto, Masatoshi; Kikkawa, Megumi; Sakugawa, Hiroshi

    2007-01-01

    Photoformation rates and scavenging rate constants of hydroxyl radicals (·OH) in natural water samples were determined by an automatic determination system. After addition of benzene as a chemical probe to a water sample in a reaction cell, light irradiation and injection of irradiated water samples into an HPLC as a function of time were performed automatically. Phenol produced by the reaction between ·OH and the benzene added to the water sample was determined to quantify the ·OH formation rate. The rate constants of ·OH formation from the photolysis of nitrate ions, nitrite ions and hydrogen peroxide were comparable with those obtained in previous studies. The percent of expected ·OH photoformation rate from added nitrate ion were high in drinking water (97.4%) and river water (99.3%). On the other hand, the low percent (65.0%) was observed in seawater due to the reaction of ·OH with the high concentrations of chloride and bromide ions. For the automatic system, the coefficient of variance for the determination of the ·OH formation rate was less than 5.0%, which is smaller than that in the previous report. When the complete time sequence of analytical cycle was 40 min for one sample, the detection limit of the photoformation rate and the sample throughput were 8 x 10 -13 M s -1 and 20 samples per day, respectively. The automatic system successfully determined the photoformation rates and scavenging rate constants of ·OH in commercial drinking water and the major source and sink of ·OH were identified as nitrate and bicarbonate ions, respectively

  10. An Analytic Model for the Success Rate of a Robotic Actuator System in Hitting Random Targets.

    Science.gov (United States)

    Bradley, Stuart

    2015-11-20

    Autonomous robotic systems are increasingly being used in a wide range of applications such as precision agriculture, medicine, and the military. These systems have common features which often includes an action by an "actuator" interacting with a target. While simulations and measurements exist for the success rate of hitting targets by some systems, there is a dearth of analytic models which can give insight into, and guidance on optimization, of new robotic systems. The present paper develops a simple model for estimation of the success rate for hitting random targets from a moving platform. The model has two main dimensionless parameters: the ratio of actuator spacing to target diameter; and the ratio of platform distance moved (between actuator "firings") to the target diameter. It is found that regions of parameter space having specified high success are described by simple equations, providing guidance on design. The role of a "cost function" is introduced which, when minimized, provides optimization of design, operating, and risk mitigation costs.

  11. Non-Markovian dynamics of quantum systems: decay rate, capture and pure states

    International Nuclear Information System (INIS)

    Kanokov, Z.; Palchikov, Yu.V.; Antonenko, N.V.; Adamian, G.G.; Kanokov, Z.; Adamian, G.G.; Scheid, W.

    2004-01-01

    Full text: With the exact numerical solution of the equation for the reduced density matrix we found a minor role of the time dependence of the friction and diffusion coefficients in the escape rate from a potential well [1]. Since the used friction and diffusion coefficients were self- consistently under certain approximations derived, they preserve the positivity of the density matrix at any time. The mixed diffusion coefficient leads to a decrease of the escape rate. Since the used value of quantum diffusion coefficient in momentum is larger than the one following from a 'classic' treatment, the obtained escape rate is close to the rate calculated with the 'classic' set of diffusion coefficients. If the regime of motion is close to the under damped case or the temperature is small, the quasi-stationary escape rate can increase with friction. This is explained by the larger role of the increasing diffusion in the decay process. The agreement of the escape rate obtained with the analytical expressions in comparison to numerically calculated data depends on the characteristics of the considered system. The agreement is better in the overdamped regime. However, for any regime the deviations are not larger than in the case of the classical Kramers formula. Therefore, the analytical expressions can be applied in a large range of parameters for the potential and diffusion coefficients. We demonstrated that the uncertainty function is related to the linear entropy. The diffusion coefficients supplying the purity of states were elaborated for the non-Markovian dynamics. The obtained dependences of the capture probability on the friction proves that the quantum nature of this process should be taken into consideration when one calculates the capture cross section in nucleus-nucleus collisions

  12. Spin-exchange and spin-destruction rates for the 3He-Na system

    International Nuclear Information System (INIS)

    Borel, P.I.; Soegaard, L.V.; Svendsen, W.E.; Andersen, N.

    2003-01-01

    Optically pumped Na is used as a spin-exchange partner to polarize 3 He. Polarizations around 20% have routinely been achieved in sealed spherical glass cells containing 3 He, N 2 , and a few droplets of Na. An optical technique has been developed to determine the Na- 3 He spin-exchange rate coefficient. By monitoring the Na spin relaxation ''in the dark,'' the average Na-Na spin-destruction cross section at 330 degree sign C is estimated to be around 5x10 -19 cm 2 . This value is 2-5 (15-30) times smaller than the previously reported values for the K-K (Rb-Rb) spin-relaxation cross section. In the temperature range 310-355 degree sign C the spin-exchange rate coefficient is found to be (6.1±0.6)x10 -20 cm 3 /s with no detectable temperature dependence. This value is in good agreement with a previous theoretical estimate reported by Walker and it is only slightly lower than the corresponding Rb- 3 He spin-exchange rate coefficient. The total Na- 3 He spin-destruction rate coefficient is, within errors, found to be the same as the Na- 3 He spin-exchange rate coefficient, thereby indicating that the maximum possible photon efficiency may approach unity for the Na- 3 He system. A technique, in which a charge-coupled device camera is used to take images of faint unquenched fluorescence light, has been utilized to allow for an instantaneous determination of the sodium number densities during the rate coefficient measurements

  13. Serious Infection Rates Among Children With Systemic Lupus Erythematosus Enrolled in Medicaid.

    Science.gov (United States)

    Hiraki, Linda T; Feldman, Candace H; Marty, Francisco M; Winkelmayer, Wolfgang C; Guan, Hongshu; Costenbader, Karen H

    2017-11-01

    To investigate the nationwide prevalence and incidence of serious infections among children with systemic lupus erythematosus (SLE) enrolled in Medicaid, the US health insurance program for low-income patients. From Medicaid claims (2000-2006) we identified children ages 5 to 30 days apart) and lupus nephritis (LN; ≥2 ICD-9 codes for kidney disease on/after SLE codes). From hospital discharge diagnoses, we identified infection subtypes (bacterial, fungal, and viral). We calculated incidence rates (IRs) per 100 person-years, mortality rates, and hazard ratios adjusted for sociodemographic factors, medications, and preventive care. Among 3,500 children with identified SLE, 1,053 serious infections occurred over 10,108 person-years; the IR was 10.42 per 100 person-years (95% confidence interval [95% CI] 9.80-11.07) among all those with SLE and 17.65 per 100 person-years (95% CI 16.29-19.09) among those with LN. Bacterial infections were most common (87%, of which 39% were bacterial pneumonias). In adjusted models, African Americans and American Indians had higher rates of infections compared with white children, and those with comorbidities or receiving corticosteroids had higher infection rates than those without. Males had lower rates of serious infections compared to females. The 30-day postdischarge mortality rate was 4.4%. Overall, hospitalized infections were very common in children with SLE, with bacterial pneumonia being the most common infection. Highest infection risks were among African American and American Indian children, those with LN, comorbidities, and those taking corticosteroids. © 2017, American College of Rheumatology.

  14. BIM-Based Decision Support System for Material Selection Based on Supplier Rating

    Directory of Open Access Journals (Sweden)

    Abiola Akanmu

    2015-12-01

    Full Text Available Material selection is a delicate process, typically hinged on a number of factors which can be either cost or environmental related. This process becomes more complicated when designers are faced with several material options of building elements and each option can be supplied by different suppliers whose selection criteria may affect the budgetary and environmental requirements of the project. This paper presents the development of a decision support system based on the integration of building information models, a modified harmony search algorithm and supplier performance rating. The system is capable of producing the cost and environmental implications of different material combinations or building designs. A case study is presented to illustrate the functionality of the developed system.

  15. Coordinated Secondary Control for Balanced Discharge Rate of Energy Storage System in Islanded Microgrids

    DEFF Research Database (Denmark)

    Guan, Yajuan; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2015-01-01

    current and unintentional outage of DGs. Thus, the stability and reliability of islanded MG can be improved. The eigenvalues and root locus with the proposed controller are presented to design the parameters as well as analyzing the system stability. Simulation results based on Matlab......A coordinated secondary control based on a novel autonomous currents sharing control strategy for balanced discharge rate of energy storage systems in islanded microgrid (MG) is proposed in this paper. The coordinated secondary controller is able to regulate the output power of distributed...... generating (DG) systems according to their state-of-charge by adjusting the virtual resistances of their voltage controlled inverters. This controller can not only provide the faster response and accurate output current sharing control, but also avoid the potential operation failure resulting from the over...

  16. Performance analysis for the bit-error rate of SAC-OCDMA systems

    Science.gov (United States)

    Feng, Gang; Cheng, Wenqing; Chen, Fujun

    2015-09-01

    Under low power, Gaussian statistics by invoking the central limit theorem is feasible to predict the upper bound in the spectral-amplitude-coding optical code division multiple access (SAC-OCDMA) system. However, this case severely underestimates the bit-error rate (BER) performance of the system under high power assumption. Fortunately, the exact negative binomial (NB) model is a perfect replacement for the Gaussian model in the prediction and evaluation. Based on NB statistics, a more accurate closed-form expression is analyzed and derived for the SAC-OCDMA system. The experiment shows that the obtained expression provides a more precise prediction of the BER performance under the low and high power assumptions.

  17. Free Floating Exchange Rate System Dan Penerapannya Pada Kebijaksanaan Ekonomi Di Negara Yang Berperekonomian Kecil Dan Terbuka

    OpenAIRE

    Atmadja, Adwin Surya

    2001-01-01

    Since the Bretton Wood sistem collapsed in early 1970s, the free floating exchange rate system has been being applied in many countries around the world. The exchange rate system choice is based on some economic advantages that will be obtained from it, considering some economic disadvantages that might be occurred. The valuation toward the advantages and disadvantages of the exchange rate system implementation exactly depends on the national economy it self, because such economy will give so...

  18. FREE FLOATING EXCHANGE RATE SYSTEM DAN PENERAPANNYA PADA KEBIJAKSANAAN EKONOMI DI NEGARA YANG BERPEREKONOMIAN KECIL DAN TERBUKA

    OpenAIRE

    Adwin Surya Atmadja

    2001-01-01

    Since the Bretton Wood sistem collapsed in early 1970s, the free floating exchange rate system has been being applied in many countries around the world. The exchange rate system choice is based on some economic advantages that will be obtained from it, considering some economic disadvantages that might be occurred. The valuation toward the advantages and disadvantages of the exchange rate system implementation exactly depends on the national economy it self, because such economy will give so...

  19. Dosimetric systems of high dose, dose rate and dose uniformity in food and medical products

    International Nuclear Information System (INIS)

    Vargas, J.; Vivanco, M.; Castro, E.

    2014-08-01

    In the Instituto Peruano de Energia Nuclear (IPEN) we use the chemical dosimetry Astm-E-1026 Fricke as a standard dosimetric system of reference and different routine dosimetric systems of high doses, according to the applied doses to obtain the desired effects in the treated products and the doses range determined for each type of dosimeter. Fricke dosimetry is a chemical dosimeter in aqueous solution indicating the absorbed dose by means an increase in absorbance at a specific wavelength. A calibrated spectrophotometer with controlled temperature is used to measure absorbance. The adsorbed dose range should cover from 20 to 400 Gy, the Fricke solution is extremely sensitive to organic impurities, to traces of metal ions, in preparing chemical products of reactive grade must be used and the water purity is very important. Using the referential standard dosimetric system Fricke, was determined to March 5, 2013, using the referential standard dosimetric system Astm-1026 Fricke, were irradiated in triplicate Fricke dosimeters, to 5 irradiation times (20; 30; 40; 50 and 60 seconds) and by linear regression, the dose rate of 5.400648 kGy /h was determined in the central point of the irradiation chamber (irradiator Gamma cell 220 Excel), applying the decay formula, was compared with the obtained results by manufacturers by means the same dosimetric system in the year of its manufacture, being this to the date 5.44691 kGy /h, with an error rate of 0.85. After considering that the dosimetric solution responds to the results, we proceeded to the irradiation of a sample of 200 g of cereal instant food, 2 dosimeters were placed at the lateral ends of the central position to maximum dose and 2 dosimeters in upper and lower ends as minimum dose, they were applied same irradiation times; for statistical analysis, the maximum dose rate was 6.1006 kGy /h and the minimum dose rate of 5.2185 kGy /h; with a dose uniformity of 1.16. In medical material of micro pulverized bone for

  20. Student laboratory experiments exploring optical fibre communication systems, eye diagrams, and bit error rates

    Science.gov (United States)

    Walsh, Douglas; Moodie, David; Mauchline, Iain; Conner, Steve; Johnstone, Walter; Culshaw, Brian

    2005-06-01

    Optical fibre communications has proved to be one of the key application areas, which created, and ultimately propelled the global growth of the photonics industry over the last twenty years. Consequently the teaching of the principles of optical fibre communications has become integral to many university courses covering photonics technology. However to reinforce the fundamental principles and key technical issues students examine in their lecture courses and to develop their experimental skills, it is critical that the students also obtain hands-on practical experience of photonics components, instruments and systems in an associated teaching laboratory. In recognition of this need OptoSci, in collaboration with university academics, commercially developed a fibre optic communications based educational package (ED-COM). This educator kit enables students to; investigate the characteristics of the individual communications system components (sources, transmitters, fibre, receiver), examine and interpret the overall system performance limitations imposed by attenuation and dispersion, conduct system design and performance analysis. To further enhance the experimental programme examined in the fibre optic communications kit, an extension module to ED-COM has recently been introduced examining one of the most significant performance parameters of digital communications systems, the bit error rate (BER). This add-on module, BER(COM), enables students to generate, evaluate and investigate signal quality trends by examining eye patterns, and explore the bit-rate limitations imposed on communication systems by noise, attenuation and dispersion. This paper will examine the educational objectives, background theory, and typical results for these educator kits, with particular emphasis on BER(COM).

  1. Conditions for testing the corrosion rates of ceramics in coal gasification systems

    Energy Technology Data Exchange (ETDEWEB)

    Hurley, J.P.; Nowok, J.W. [Univ. of North Dakota, Grand Forks, ND (United States)

    1996-08-01

    Coal gasifier operating conditions and gas and ash compositions affect the corrosion rates of ceramics used for construction in three ways: (1) through direct corrosion of the materials, (2) by affecting the concentration and chemical form of the primary corrodents, and (3) by affecting the mass transport rate of the primary corrodents. To perform an accurate corrosion test on a system material, the researcher must include all relevant corrodents and simulate conditions in the gasifier as closely as possible. In this paper, the authors present suggestions for conditions to be used in such corrosion tests. Two main types of corrosion conditions are discussed: those existing in hot-gas cleanup systems where vapor and dry ash may contribute to corrosion and those experienced by high-temperature heat exchangers and refractories where the main corrodent will be coal ash slag. Only the fluidized-bed gasification systems such as the Sierra Pacific Power Company Pinon Pine Power Project system are proposing the use of ceramic filters for particulate cleanup. The gasifier is an air-blown 102-MWe unit employing a Westinghouse{trademark} ceramic particle filter system operating at as high as 1100{degrees}F at 300 psia. Expected gas compositions in the filter will be approximately 25% CO, 15% H{sub 2}, 5% CO{sub 2}, 5% H{sub 2}O, and 50% N{sub 2}. Vapor-phase sodium chloride concentrations are expected to be 10 to 100 times the levels in combustion systems at similar temperatures, but in general the concentrations of the minor primary and secondary corrodents are not well understood. Slag corrosiveness will depend on its composition as well as viscosity. For a laboratory test, the slag must be in a thermodynamically stable form before the beginning of the corrosion test to assure that no inappropriate reactions are allowed to occur. Ideally, the slag would be flowing, and the appropriate atmosphere must be used to assure realistic slag viscosity.

  2. Pregnancy risk assessment monitoring system in Ireland: methods and response rates

    LENUS (Irish Health Repository)

    O’Keeffe, Linda M.

    2014-06-01

    To describe response rates and characteristics associated with response to the Pregnancy Risk Assessment Monitoring System study in Ireland (PRAMS Ireland). Using hospital discharge records of live births at a large, urban, obstetric hospital, a sampling frame of approximately 2,400 mother-infant pairs were used to alternately sample 1,200 women. Mothers’ information including name, address, parity, age and infant characteristics such as sex and gestational age at delivery were extracted from records. Modes of contact included an invitation letter with option to opt out of the study, three mail surveys, a reminder letter and text message reminder for remaining non-respondents. Sixty-one per cent of women responded to the PRAMS Ireland survey over a 133 day response period. Women aged <30, single women, multiparous women and women with a preterm delivery were less likely to respond. Women participating in PRAMS Ireland were similar to the national birth profile in 2011 which had a mean age of 32, were 40 % primiparous, 33 % single or never married and had a 28 % caesarean section rate. Survey and protocol changes are required to increase response rates above recommended Centers for Disease Control and Prevention (CDC) thresholds of 65 % within the recommended 90 day data collection cycle. Additional efforts such as stratification and over-sampling are required to increase representativeness among hard to reach groups such as younger, single and multiparous women before expanding the project to an ongoing, national surveillance system in Ireland.

  3. Research on the optoacoustic communication system for speech transmission by variable laser-pulse repetition rates

    Science.gov (United States)

    Jiang, Hongyan; Qiu, Hongbing; He, Ning; Liao, Xin

    2018-06-01

    For the optoacoustic communication from in-air platforms to submerged apparatus, a method based on speech recognition and variable laser-pulse repetition rates is proposed, which realizes character encoding and transmission for speech. Firstly, the theories and spectrum characteristics of the laser-generated underwater sound are analyzed; and moreover character conversion and encoding for speech as well as the pattern of codes for laser modulation is studied; lastly experiments to verify the system design are carried out. Results show that the optoacoustic system, where laser modulation is controlled by speech-to-character baseband codes, is beneficial to improve flexibility in receiving location for underwater targets as well as real-time performance in information transmission. In the overwater transmitter, a pulse laser is controlled to radiate by speech signals with several repetition rates randomly selected in the range of one to fifty Hz, and then in the underwater receiver laser pulse repetition rate and data can be acquired by the preamble and information codes of the corresponding laser-generated sound. When the energy of the laser pulse is appropriate, real-time transmission for speaker-independent speech can be realized in that way, which solves the problem of underwater bandwidth resource and provides a technical approach for the air-sea communication.

  4. A new method to determine reflex latency induced by high rate stimulation of the nervous system

    Directory of Open Access Journals (Sweden)

    Ilhan eKaracan

    2014-07-01

    Full Text Available High rate stimulations of the neuromuscular system, such as continuous whole body vibration, tonic vibration reflex and high frequency electrical stimulation, are used in the physiological research with an increasing interest. In these studies, the neuronal circuitries underlying the reflex responses remain unclear due to the problem of determining the exact reflex latencies. We present a novel cumulated average method to determine the reflex latency during high rate stimulation of the nervous system which was proven to be significantly more accurate than the classical method. The classical method, cumulant density analysis, reveals the relationship between the two synchronously recorded signals as a function of the lag between the signals. The comparison of new method with the classical technique and their relative accuracy was tested using a computer simulation. In the simulated signals the EMG response latency was constructed to be exactly 40 ms. The new method accurately indicated the value of the simulated reflex latency (40 ms. However, the classical method showed that the lag time between the simulated triggers and the simulated signals was 49 ms. Simulation results illustrated that the cumulated average method is a reliable and more accurate method compared with the classical method. We therefore suggest that the new cumulated average method is able to determine the high rate stimulation induced reflex latencies more accurately than the classical method.

  5. Influence of Production System, Sex and Litter Size on Growth Rates in Turcana Lambs

    Directory of Open Access Journals (Sweden)

    Dinu Gavojdian

    2013-10-01

    Full Text Available Lamb meat production has become the main source of income in the Romanian sheep farming industry, representing over 66% of the total returns. Turcana breed represents over 70% of the national flock, and 92% of the sheep bred in western Romania. However, meat production potential and growth rates of the breed are low, and thus strategies to improve performance of the Turcana lambs need to be identified. Aim of the current research was to evaluate the effects that sex and litter size have on the growth rates of lambs from Turcana breed under extensive and semi-intensive production systems. Weaning weight was significantly (p≤0.001 influenced by the production system, with lambs reared extensively registering a average body weights of 18.23±0.094 kg at the age of 90 days, while the semi-intensively reared lambs registered an average weight of 20.19±0.082 kg. It was concluded that all three factors taken into study significantly influence growth rates in Turcana lambs and that weight of the lamb(s at the age of 28 days should be included as a selection trait within the Turcana breed genetic improvement plan.

  6. Success rates of a skeletal anchorage system in orthodontics: A retrospective analysis.

    Science.gov (United States)

    Lam, Raymond; Goonewardene, Mithran S; Allan, Brent P; Sugawara, Junji

    2018-01-01

    To evaluate the premise that skeletal anchorage with SAS miniplates are highly successful and predictable for a range of complex orthodontic movements. This retrospective cross-sectional analysis consisted of 421 bone plates placed by one clinician in 163 patients (95 female, 68 male, mean age 29.4 years ± 12.02). Simple descriptive statistics were performed for a wide range of malocclusions and desired movements to obtain success, complication, and failure rates. The success rate of skeletal anchorage system miniplates was 98.6%, where approximately 40% of cases experienced mild complications. The most common complication was soft tissue inflammation, which was amenable to focused oral hygiene and antiseptic rinses. Infection occurred in approximately 15% of patients where there was a statistically significant correlation with poor oral hygiene. The most common movements were distalization and intrusion of teeth. More than a third of the cases involved complex movements in more than one plane of space. The success rate of skeletal anchorage system miniplates is high and predictable for a wide range of complex orthodontic movements.

  7. High rate gamma spectroscopy system for activation analysis of short-lived isomeric transitions

    Energy Technology Data Exchange (ETDEWEB)

    Westphall, G P [Atominstitut der Oesterreichischen Hochschulen, Vienna

    1976-07-15

    A high rate spectroscopy system specially suited for measurement of short-lived isomeric transitions is described, which, as part of a fast activation analysis facility at the TRIGA Mark II reactor, provides for automatic recording and immediate evaluation of gamma spectra taken from nuclides activated at stationary or pulsed reactor power. The system consists of a commercial de-coupled Ge(Li)-detector of 70 cm/sup 3/ modified for recycling operation for input rates in excess of 500000 c/s /sup 60/Co, a time variant trapezoidal shaping section and a fast constant dead-time ADC coupled to a programmed multichannel analyzer. Novel circuits for efficient pile-up rejection and time variant base line restoration extend the concept of gated integration up to count rates of more than 200000 c/s /sup 60/Co. Time-sequenced recording of spectra is performed by a minicomputer operated as a front-end processor of a larger laboratory computer, where final data processing takes place. New concepts for very simple and cost-effective implementation of multichannel analyzers by means of general purpose small computers are described.

  8. REVIEW ARTICLE: How do biomolecular systems speed up and regulate rates?

    Science.gov (United States)

    Zhou, Huan-Xiang

    2005-09-01

    The viability of a biological system depends upon careful regulation of the rates of various processes. These rates have limits imposed by intrinsic chemical or physical steps (e.g., diffusion). These limits can be expanded by interactions and dynamics of the biomolecules. For example, (a) a chemical reaction is catalyzed when its transition state is preferentially bound to an enzyme; (b) the folding of a protein molecule is speeded up by specific interactions within the transition-state ensemble and may be assisted by molecular chaperones; (c) the rate of specific binding of a protein molecule to a cellular target can be enhanced by mechanisms such as long-range electrostatic interactions, nonspecific binding and folding upon binding; (d) directional movement of motor proteins is generated by capturing favorable Brownian motion through intermolecular binding energy; and (e) conduction and selectivity of ions through membrane channels are controlled by interactions and the dynamics of channel proteins. Simple physical models are presented here to illustrate these processes and provide a unifying framework for understanding speed attainment and regulation in biomolecular systems.

  9. A high rate gamma spectroscopy system for activation analysis of short lived isomeric transitions

    Energy Technology Data Exchange (ETDEWEB)

    Westphal, G P [Atominstitut, Vienna (Austria)

    1976-07-01

    A high rate spectroscopy system specially suited for measurement of short-lived isomeric transitions is described, which, as part of a fast activation analysis facility at the TRIGA Mark II reactor, provides for automatic recording and immediate evaluation of gamma spectra taken from nuclides activated at stationary or pulsed reactor power. The system consists of a commercial DC-coupled Ge(Li)-detector of 70 cm{sup 3} modified for recycling operation for input rates in excess of 500,000 c/s Co-60, a time variant trapezoidal shaping section and a fast constant dead-time ADC coupled to a programmed multi-channel analyzer. Novel circuits for efficient pile-up rejection and time variant base line restoration extend the concept of gated integration up to count rates of more than 300,000 c/s Co-60. Time-sequenced recording of spectra is performed by a mini computer operated as a front-end processor of a larger laboratory computer, where final data processing takes place. New concepts for very simple and cost-effective implementation of multi-channel analyzers by means of general purpose small computers are described. (author)

  10. Critical heat flux and exit film flow rate in a flow boiling system

    International Nuclear Information System (INIS)

    Ueda, Tatsuhiro; Isayama, Yasushi

    1981-01-01

    The critical heat flux in a flowing boiling system is an important problem in the evaporating tubes with high thermal load such as nuclear reactors and boilers, and gives the practical design limit. When the heat flux in uniformly heated evaporating tubes is gradually raised, the tube exit quality increases, and soon, the critical heat flux condition arises, and the wall temperature near tube exit rises rapidly. In the region of low exit quality, the critical heat flux condition is caused by the transition from nucleating boiling, and in the region of high exit quality, it is caused by dry-out. But the demarcation of both regions is not clear. In this study, for the purpose of obtaining the knowledge concerning the critical heat flux condition in a flowing boiling system, the relation between the critical heat flux and exit liquid film flow rate was examined. For the experiment, a uniformly heated vertical tube supplying R 113 liquid was used, and the measurement in the range of higher heating flux and mass velocity than the experiment by Ueda and Kin was carried out. The experimental setup and experimental method, the critical heat flux and exit quality, the liquid film flow rate at heating zone exit, and the relation between the critical heat flux and the liquid film flow rate at exit are described. (Kako, I.)

  11. Estimation of daily flow rate of photovoltaic water pumping systems using solar radiation data

    Science.gov (United States)

    Benghanem, M.; Daffallah, K. O.; Almohammedi, A.

    2018-03-01

    This paper presents a simple model which allows us to contribute in the studies of photovoltaic (PV) water pumping systems sizing. The nonlinear relation between water flow rate and solar power has been obtained experimentally in a first step and then used for performance prediction. The model proposed enables us to simulate the water flow rate using solar radiation data for different heads (50 m, 60 m, 70 m and 80 m) and for 8S × 3P PV array configuration. The experimental data are obtained with our pumping test facility located at Madinah site (Saudi Arabia). The performances are calculated using the measured solar radiation data of different locations in Saudi Arabia. Knowing the solar radiation data, we have estimated with a good precision the water flow rate Q in five locations (Al-Jouf, Solar Village, AL-Ahsa, Madinah and Gizan) in Saudi Arabia. The flow rate Q increases with the increase of pump power for different heads following the nonlinear model proposed.

  12. Experimental investigation on the high chip rate of 2D incoherent optical CDMA system

    Science.gov (United States)

    Su, Guorui; Wang, Rong; Pu, Tao; Fang, Tao; Zheng, Jilin; Zhu, Huatao; Wu, Weijiang

    2015-08-01

    An innovative approach to realise high chip rate in OCDMA transmission system is proposed and experimentally investigation, the high chip rate is achieved through a 2-D wavelength-hopping time-spreading en/decoder based on the supercontinuum light source. The source used in the experiment is generated by high nonlinear optical fiber (HNLF), Erbium-doped fiber amplifier (EDFA) which output power is 26 dBm, and distributed feed-back laser diode which works in the gain switch state. The span and the flatness of the light source are 20 nm and 3 dB, respectively, after equalization of wavelength selective switch (WSS). The wavelength-hopping time-spreading coder can be changed 20 nm in the wavelength and 400 ps in the time, is consist of WSS and delay lines. Therefore, the experimental results show that the chip rate can achieve 500 Gchip/s, in the case of 2.5 Gbit/s, while keeping a bit error rate below forward error correction limit after 40 km transmission.

  13. Relationships between stocking rate, livestock production systems and Alpine grasslands management

    Directory of Open Access Journals (Sweden)

    Enrico Sturaro

    2010-01-01

    Full Text Available This study was conducted in order to identify the relationships between stocking rate, management system, topographic conditions and weed encroachment of summer pastures in “Lessinia”, a pre-Alpine area in the Veneto region (North-Eastern Italy. Using the data from a field survey on 46 summer pastures (30 with dairy cows and 16 with other bovine categories, various ANOVA/ANCOVA models were used to test the effects on stocking rate of livestock category, supplementary concentrate feeding, and pasture weed encroachment, slope and elevation. Stocking rate was higher in summer pastures with dairy cows than in those with other bovine categories, and in pastures with moderate slopes than in those with higher ones, but was unaffected by supplementary concentrate feeding, altitude and weed encroachment. This indicates that in the considered areas stocking rate is not constrained by pasture productivity and is kept at sub-optimal levels. Future research is needed to make more clear the effects that the present management status may have on the evolution of pastures productivity and biodiversity value.

  14. [A Quality Assurance (QA) System with a Web Camera for High-dose-rate Brachytherapy].

    Science.gov (United States)

    Hirose, Asako; Ueda, Yoshihiro; Oohira, Shingo; Isono, Masaru; Tsujii, Katsutomo; Inui, Shouki; Masaoka, Akira; Taniguchi, Makoto; Miyazaki, Masayoshi; Teshima, Teruki

    2016-03-01

    The quality assurance (QA) system that simultaneously quantifies the position and duration of an (192)Ir source (dwell position and time) was developed and the performance of this system was evaluated in high-dose-rate brachytherapy. This QA system has two functions to verify and quantify dwell position and time by using a web camera. The web camera records 30 images per second in a range from 1,425 mm to 1,505 mm. A user verifies the source position from the web camera at real time. The source position and duration were quantified with the movie using in-house software which was applied with a template-matching technique. This QA system allowed verification of the absolute position in real time and quantification of dwell position and time simultaneously. It was evident from the verification of the system that the mean of step size errors was 0.31±0.1 mm and that of dwell time errors 0.1±0.0 s. Absolute position errors can be determined with an accuracy of 1.0 mm at all dwell points in three step sizes and dwell time errors with an accuracy of 0.1% in more than 10.0 s of the planned time. This system is to provide quick verification and quantification of the dwell position and time with high accuracy at various dwell positions without depending on the step size.

  15. A quality assurance (QA) system with a web camera for high-dose-rate brachytherapy

    International Nuclear Information System (INIS)

    Hirose, Asako; Ueda, Yoshihiro; Ohira, Shingo

    2016-01-01

    The quality assurance (QA) system that simultaneously quantifies the position and duration of an 192 Ir source (dwell position and time) was developed and the performance of this system was evaluated in high-dose-rate brachytherapy. This QA system has two functions to verify and quantify dwell position and time by using a web camera. The web camera records 30 images per second in a range from 1,425 mm to 1,505 mm. A user verifies the source position from the web camera at real time. The source position and duration were quantified with the movie using in-house software which was applied with a template-matching technique. This QA system allowed verification of the absolute position in real time and quantification of dwell position and time simultaneously. It was evident from the verification of the system that the mean of step size errors was 0.3±0.1 mm and that of dwell time errors 0.1 ± 0.0 s. Absolute position errors can be determined with an accuracy of 1.0 mm at all dwell points in three step sizes and dwell time errors with an accuracy of 0.1% in more than 10.0 s of the planned time. This system is to provide quick verification and quantification of the dwell position and time with high accuracy at various dwell positions without depending on the step size. (author)

  16. Postoperative groin pain and success rates following transobturator midurethral sling placement: TVT ABBREVO® system versus TVT™ obturator system.

    Science.gov (United States)

    Canel, Virginie; Thubert, Thibault; Wigniolle, Ingrid; Fernandez, Hervé; Deffieux, Xavier

    2015-10-01

    Placement of a transobturator midurethral sling (MUS) is the standard surgical treatment for stress urinary incontinence. Most recent MUS procedures have been poorly evaluated. We compared the results using a "new" device expected to reduce postoperative pain, the TVT ABBREVO® system (TVT-Abb), with those using the TVT™ obturator system (TVT-O). This was a retrospective study comparing the use of the TVT-Abb (in 50 patients) and the TVT-O (in 50 patients). The main outcomes were the amount of postoperative pain, the success rate (no reported urinary leakage and negative cough test) with both MUS procedures, and the prevalence of complications. The mean follow-up time was 12 months. The preoperative characteristics of the two groups were comparable. There was less postoperative pain (VAS, 0 to 100) in the TVT-Abb group than in the TVT-O group (12.2 vs. 24.4, p TVT-Abb group and the TVT-O group (8 % vs. 12 %, p = 0.74). The prevalences of perioperative and postoperative complications (bladder/urethral injury, haemorrhage) in the two groups were equal. The success rates were similar at 12 months after surgery (88 % vs. 78 %, p = 0.29). The success rates with TVT-Abb and TVT-O were equal at 12 months after surgery, but there was less immediate postoperative pain with TVT-Abb.

  17. ELS-LEED-study of low-dimensional plasmons in DySi2 layers and nanowires

    International Nuclear Information System (INIS)

    Rugeramigabo, Eddy Patrick

    2007-01-01

    Low-dimensional dysprosium silicide metal systems grown on Si have been characterized by means of energy loss spectroscopy of low energy electron diffraction. The several silicide phases depending on the growth conditions have been observed. Moreover collective charge excitations were clearly detected and identified as low-dimensional plasmons which have a different dispersion compared to the well known bulk and surface plasmons. Dy-silicide has been grown on Si(111) by means of molecular beam epitaxy. Due to its small lattice mismatch (-0.3%) to Si(111), Dy-silicide grows in epitaxial high quality crystalline layers. In the submonolayer regime, many silicide phases coexist until the silicide coverage approaches 1ML, and shows the characteristic 1 x 1 diffraction pattern with the stoichiometry DySi 2 . With further increasing of the coverage, the silicide turns to the multilayer phase. The collective electronic excitations in the monolayer structure have been found to have a 2D-character. Accordingly the plasmon dispersion reaches zero in the long-wavelength limit (at vanishing wave number q) and shows a √(q) behaviour until it entered the domain of strong damping. When grown on Si (001) the Dy-silicide formed an array of parallel nanowires, in the direction normal to the dimer row direction and their length was limited by the crossing of another nanowire. A structure dependent energy loss was observed: the energy loss were only sufficiently intense when the 7 x 2 reconstruction has formed. An possibility of creating vast area with only parallel nanowires in one direction was performed on vicinal Si(001) with four degree miscut. At the same coverage where the 7 x 2 reconstruction occurs on flat Si(001), it was surprising that, besides the 7 x 2 periodicity, the diffraction pattern revealed a mixture of phases, with periodicities ranging from the 10 x 2 to that of the 7 x 2, which was observed as the limit of shifting reflex positions. We were able to confirm the

  18. New system for higher recovery rate of water borne Cryptosporidium oocysts and Giardia cysts

    DEFF Research Database (Denmark)

    Al-Sabi, Mohammad Nafi Solaiman; Gad, Jens; Klinting, Mette

    2012-01-01

    Background: The two most common water borne pathogenic protozoa, Cryptosporidium and Giardia, cause diarrhea worldwide. Detecting these parasites in water samples depends on effective parasite recovery from the water matrix. The reported low recovery rates of the currently used filter methods...... motivate the development of systems with higher recovery rates. Materials and methods: Five replicates of IMS purified Cryptosporidium oocysts and Giardia cysts (N=2x103) were injected into a specially coated filter unit with a carefully chosen pore size. Following filtration, sonication was performed...... were 85% were recorded when the filter was sonicated. Sonication usually affects parasite viability but could be tuned into a useful tool for enhanced backwash collection of parasites using a specially constructed filter unit and a sonication protocol. The filtration...

  19. Quenching rate for a nonlocal problem arising in the micro-electro mechanical system

    Science.gov (United States)

    Guo, Jong-Shenq; Hu, Bei

    2018-03-01

    In this paper, we study the quenching rate of the solution for a nonlocal parabolic problem which arises in the study of the micro-electro mechanical system. This question is equivalent to the stabilization of the solution to the transformed problem in self-similar variables. First, some a priori estimates are provided. In order to construct a Lyapunov function, due to the lack of time monotonicity property, we then derive some very useful and challenging estimates by a delicate analysis. Finally, with this Lyapunov function, we prove that the quenching rate is self-similar which is the same as the problem without the nonlocal term, except the constant limit depends on the solution itself.

  20. Experimental constraints on heating and cooling rates of refractory inclusions in the early solar system

    International Nuclear Information System (INIS)

    Boynton, W.V.

    1987-01-01

    The refractory inclusions in carbonaceous chondrites were the subject of considerable interest since their discovery. These inclusions contain minerals that are predicted to be some of the earliest condensates from the solar nebula, and contain a plethora of isotopic anomalies of unknown origin. Of particular interest are those coarse-grained inclusions that contain refractory metal particles (Fe, Ni, Pt, Ru, Os Ir). Experimental studies of these inclusions in terrestrial laboratories are, however, complicated because the dense particles tend to settle out of a molten or partially molten silicate material. Heating experiments in the Space Station technology and microgravity in order to observe the effects of metal nuggets (which may act as heterogeneous nucleation sites) on nucleation rates in silicate systems and to measure simultaneously the relative volatilization rate of siderophile and lithophile species. Neither experiment is possible in the terrestrial environment

  1. Free energy correlation of rate constants for electron transfer between organic systems in aqueous solutions

    Energy Technology Data Exchange (ETDEWEB)

    Meisel, D

    1975-07-15

    Recent experimental data concerning the rate constants for electron transfer reactions of organic systems in aqueous solutions and their equilibrium constants is examined for possible correlation. The data is correlated quite well by the Marcus theory, if a reorganization parameter, lambda, of 18 kcal/mole is used. Assuming that the only contribution to lambda is the free energy of rearrangement of the water molecules, an effective radius of 5 A for the reacting entities is estimated. For the zero free energy change reaction, i.e., electron exchange between a radical ion and its parent molecule, a rate constant of about 5 X 10/sup 7/ M/sup -1/ s/sup -1/ is predicted. (auth)

  2. On Bandwidth Efficient Modulation for High-Data-Rate Wireless LAN Systems

    Directory of Open Access Journals (Sweden)

    Stolpman Victor

    2002-01-01

    Full Text Available We address the problem of high-data-rate orthogonal frequency division multiplexed (OFDM systems under restrictive bandwidth constraints. Based on recent theoretic results, multiple-input multiple-output (MIMO configurations are best suited for this problem. In this paper, we examine several MIMO configurations suitable for high rate transmission. In all scenarios considered, perfect channel state information (CSI is assumed at the receiver. In constrast, availability of CSI at the transmitter is addressed separately. We show that powerful space-time codes can be developed by combining some simple well-known techniques. In fact, we show that for certain configurations, these space-time MIMO configurations are near optimum in terms of outage capacity as compared to previously published codes. Performance evaluation of these techniques is demonstrated within the IEEE 802.11a framework via Monte Carlo simulations.

  3. Dynamics and profiles of a diffusive host-pathogen system with distinct dispersal rates

    Science.gov (United States)

    Wu, Yixiang; Zou, Xingfu

    2018-04-01

    In this paper, we investigate a diffusive host-pathogen model with heterogeneous parameters and distinct dispersal rates for the susceptible and infected hosts. We first prove that the solution of the model exists globally and the model system possesses a global attractor. We then identify the basic reproduction number R0 for the model and prove its threshold role: if R0 ≤ 1, the disease free equilibrium is globally asymptotically stable; if R0 > 1, the solution of the model is uniformly persistent and there exists a positive (pathogen persistent) steady state. Finally, we study the asymptotic profiles of the positive steady state as the dispersal rate of the susceptible or infected hosts approaches zero. Our result suggests that the infected hosts concentrate at certain points which can be characterized as the pathogen's most favoured sites when the mobility of the infected host is limited.

  4. Two 175 ton geothermal chiller heat pumps for leed platinum building technology demonstration project. Operation data, data collection and marketing

    Energy Technology Data Exchange (ETDEWEB)

    Kolo, Daniel [Johnson Controls, Inc., Glendale, WI (United States)

    2016-08-15

    The activities funded by this grant helped educate and inform approximately six thousand individuals who participated in guided tours of the geothermal chiller plant at Johnson Controls Corporate Headquarters in Glendale, Wisconsin over the three year term of the project. In addition to those who took the formal tour, thousands more were exposed to hands-on learning at the self-service video kiosks located in the headquarters building and augmented reality tablet app that allowed for self-guided tours. The tours, video, and app focused on the advantages of geothermal heat pump chillers, including energy savings and environmental impact. The overall tour and collateral also demonstrated the practical application of this technology and how it can be designed into a system that includes many other sustainable technologies without sacrificing comfort or health of building occupants Among tour participants were nearly 1,000 individuals, representing 130 organizations identified as potential purchasers of geothermal heat pump chillers. In addition to these commercial clients, tours were well attended by engineering, facilities, and business trade groups. This has also been a popular tour for groups from Universities around the Midwest and K-12 schools from Wisconsin and Northern Illinois A sequence of operations was put into place to control the chillers and they have been tuned and maintained to optimize the benefit from the geothermal water loop. Data on incoming and outgoing water temperature and flow from the geothermal field was logged and sent to DOE monthly during the grant period to demonstrate energy savings.

  5. Photolithography and Fluorescence Correlation Spectroscopy used to examine the rates of exchange in reverse micelle systems

    Science.gov (United States)

    Norris, Zach; Mawson, Cara; Johnson, Kyron; Kessler, Sarah; Rebecca, Anne; Wolf, Nathan; Lim, Michael; Nucci, Nathaniel

    Reverse micelles are molecular complexes that encapsulate a nanoscale pool of water in a surfactant shell dissolved in non-polar solvent. These complexes have a wide range of applications, and in all cases, the degree to which reverse micelles (RM) exchange their contents is relevant for their use. Despite its importance, this aspect of RM behavior is poorly understood. Photolithography is employed here to create micro and nano scale fluidic systems in which mixing rates can be precisely measured using fluorescence correlation spectroscopy (FCS). Micro-channel patterns are etched using reactive ion etching process into a layer of silicon dioxide on crystalline silicon substrates. Solutions containing mixtures of reverse micelles, proteins, and fluorophores are placed into reservoirs in the patterns, while diffusion and exchange between RMs is monitored using a FCS system built from a modified confocal Raman spectrometer. Using this approach, the diffusion and exchange rates for RM systems are measured as a function of the components of the RM mixture. Funding provided by Rowan University.

  6. The Impact of an Electronic Ordering System on Blood Bank Specimen Rejection Rates.

    Science.gov (United States)

    Forest, Stefanie K; Shirazi, Maryam; Wu-Gall, Charlotte; Stotler, Brie A

    2017-01-01

    To evaluate the impact that an electronic ordering system has on the rate of rejection of blood type and screen testing samples and the impact on the number of ABO blood-type discrepancies over a 4-year period. An electronic ordering system was implemented in May 2011. Rejection rates along with reasons for rejection were tracked between January 2010 and December 2013. A total of 40,104 blood samples were received during this period, of which 706 (1.8%) were rejected for the following reasons: 382 (54.0%) unsigned samples, 235 (33.0%) mislabeled samples, 57 (8.0%) unsigned requisitions, 18 (2.5%) incorrect tubes, and 14 (1.9%) ABO discrepancies. Of the samples, 2.5% were rejected in the year prior to implementing the electronic ordering system compared with 1.2% in the year following implementation ( P  blood sample rejection. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  7. Development of a Behavioural Marker System for Rating Cadet’s Non-Technical Skills

    Directory of Open Access Journals (Sweden)

    Victor Fernando PlÁcido da ConceiçÌo

    2017-06-01

    Full Text Available Despite the adoption of crew resource management training for bridge teams over the last decades, the training is still heavily focussed on technical achievements. In an educational context, the situation is more problematical, since with requirement of developing the technical skills, there is a need to build and evaluate the non-technical skills of cadets with little experience in bridge team management. In parallel with the application of team leadership models, the Portuguese Naval Academy conducted a research to improve the development and assessment of non-technical skills in bridge simulators. This paper describes the method used to identify the key non-technical skills required for naval cadets and to develop a behavioural marker system for their measurement. A literature review of behavioural marker systems was supplemented with an analysis of interviews conducted with students and simulator instructors. Additionally, further analysis of Portuguese Navy accidents reports was made, applying the HFACS framework to identify the relevant non-technical skills involved in the accidents. The resulting rating system covers five skill categories (leadership, situational awareness, communication, team work and decision making, each one with three rating elements. The framework is currently under evaluation tests in bridge simulators sessions, within an educational context.

  8. Structure and grain coarsening during the processing of engineering ceramics. Ph.D. Thesis - Leeds Univ., United Kingdom

    Science.gov (United States)

    Shaw, Nancy J.

    1987-01-01

    Studies have been made of three ceramic systems (Al2O3, Y2O3/MgO, and SiC/C/B), both to explore a surface area/density diagram approach to examining the coarsening processes during sintering and to explore an alternative coarsening parameter, i.e., the grain boundary surface area (raising it at a given value of the density) and not the pore surface area; therefore, pinning of the grain boundaries by solid-solution drag is the only function evidenced by these results. The importance of such pinning even at densities as low as 75% of theoretical is linked to the existence of microstructural inhomogeneities. The early stages of sintering of Y2O3 powder have been examined using two techniques, BET surface area analysis and transmission electron microscopy. Each has given some insight into the process occurring and, used together, have provided some indication of the effect of MgO on coarsening during sintering. Attempts to further elucidate effects of MgO on the coarsening behavior of Y2O3 by the surface area/density diagram approach were unsuccessful due to masking effects of contaminating reactions during sintering and/or thermal etching. The behavior of the undoped SiC which only coarsens can be clearly distinguished by the surface area/density diagram from that of SiC/C/B which also concurrently densifies. Little additional information was obtainable by this method due to unfavorable sample etching characteristics. The advantages, disadvantages, and difficulties of application of these techniques to the study of coarsening during sintering are discussed.

  9. Rating the Efficiency of Regional Health Systems and Compulsory Health Insurance

    Directory of Open Access Journals (Sweden)

    Tatyana Nikolayevna Russkikh

    2015-12-01

    Full Text Available In the face of increasing of the regional differentiation of the health systems and compulsory health insurance, the comparative analysis and efficiency assessment of their performance in the context of the subjects of the Russian Federation becomes particularly relevant. Therefore, the research is focused on the regional health systems and compulsory health insurance (CHI, and the subject matter of the study is the analysis of the system performance. In the article, the comparative analysis of the authors’ approaches to the formation of efficiency criteria of the performance of regional health systems and CHI, as well as to the development of a typology of the constituent entities of the Russian Federation based on these criteria is conducted. The authors propose a system of indicators to measure the economic, medical and social efficiency of the systems under consideration. Moreover, a set of indicators of economic efficiency forms two groups of indicators. The first group of indicators reflects the financial performance, and the second — the structural efficiency. A methodological approach to the formation of the rating for subjects of the Russian Federation according to the levels of efficiency, based on the procedures of cluster analysis and fuzzy mathematics are developed. A feature of the proposed approach to the construction of a typology of the subjects in terms of efficiency is the introduction of a reference subject with the national average performance indicators system that allows to qualitatively assess the effectiveness of regional health systems and CHI by comparing them with the «reference subject». The results of the empirical research have indicated a high differentiation of the subjects of the Russian Federation in terms of economic efficiency, have allowed to identify the subjects-outsiders. The theoretical and practical results can be used for the rational choice of priorities of the state policy in the field of the

  10. Dispensing error rate after implementation of an automated pharmacy carousel system.

    Science.gov (United States)

    Oswald, Scott; Caldwell, Richard

    2007-07-01

    A study was conducted to determine filling and dispensing error rates before and after the implementation of an automated pharmacy carousel system (APCS). The study was conducted in a 613-bed acute and tertiary care university hospital. Before the implementation of the APCS, filling and dispensing rates were recorded during October through November 2004 and January 2005. Postimplementation data were collected during May through June 2006. Errors were recorded in three areas of pharmacy operations: first-dose or missing medication fill, automated dispensing cabinet fill, and interdepartmental request fill. A filling error was defined as an error caught by a pharmacist during the verification step. A dispensing error was defined as an error caught by a pharmacist observer after verification by the pharmacist. Before implementation of the APCS, 422 first-dose or missing medication orders were observed between October 2004 and January 2005. Independent data collected in December 2005, approximately six weeks after the introduction of the APCS, found that filling and error rates had increased. The filling rate for automated dispensing cabinets was associated with the largest decrease in errors. Filling and dispensing error rates had decreased by December 2005. In terms of interdepartmental request fill, no dispensing errors were noted in 123 clinic orders dispensed before the implementation of the APCS. One dispensing error out of 85 clinic orders was identified after implementation of the APCS. The implementation of an APCS at a university hospital decreased medication filling errors related to automated cabinets only and did not affect other filling and dispensing errors.

  11. Lyapunov Exponent and Out-of-Time-Ordered Correlator's Growth Rate in a Chaotic System.

    Science.gov (United States)

    Rozenbaum, Efim B; Ganeshan, Sriram; Galitski, Victor

    2017-02-24

    It was proposed recently that the out-of-time-ordered four-point correlator (OTOC) may serve as a useful characteristic of quantum-chaotic behavior, because, in the semiclassical limit ℏ→0, its rate of exponential growth resembles the classical Lyapunov exponent. Here, we calculate the four-point correlator C(t) for the classical and quantum kicked rotor-a textbook driven chaotic system-and compare its growth rate at initial times with the standard definition of the classical Lyapunov exponent. Using both quantum and classical arguments, we show that the OTOC's growth rate and the Lyapunov exponent are, in general, distinct quantities, corresponding to the logarithm of the phase-space averaged divergence rate of classical trajectories and to the phase-space average of the logarithm, respectively. The difference appears to be more pronounced in the regime of low kicking strength K, where no classical chaos exists globally. In this case, the Lyapunov exponent quickly decreases as K→0, while the OTOC's growth rate may decrease much slower, showing a higher sensitivity to small chaotic islands in the phase space. We also show that the quantum correlator as a function of time exhibits a clear singularity at the Ehrenfest time t_{E}: transitioning from a time-independent value of t^{-1}lnC(t) at ttime at t>t_{E}. We note that the underlying physics here is the same as in the theory of weak (dynamical) localization [Aleiner and Larkin, Phys. Rev. B 54, 14423 (1996)PRBMDO0163-182910.1103/PhysRevB.54.14423; Tian, Kamenev, and Larkin, Phys. Rev. Lett. 93, 124101 (2004)PRLTAO0031-900710.1103/PhysRevLett.93.124101] and is due to a delay in the onset of quantum interference effects, which occur sharply at a time of the order of the Ehrenfest time.

  12. Novel hybrid Monte Carlo/deterministic technique for shutdown dose rate analyses of fusion energy systems

    International Nuclear Information System (INIS)

    Ibrahim, Ahmad M.; Peplow, Douglas E.; Peterson, Joshua L.; Grove, Robert E.

    2014-01-01

    Highlights: •Develop the novel Multi-Step CADIS (MS-CADIS) hybrid Monte Carlo/deterministic method for multi-step shielding analyses. •Accurately calculate shutdown dose rates using full-scale Monte Carlo models of fusion energy systems. •Demonstrate the dramatic efficiency improvement of the MS-CADIS method for the rigorous two step calculations of the shutdown dose rate in fusion reactors. -- Abstract: The rigorous 2-step (R2S) computational system uses three-dimensional Monte Carlo transport simulations to calculate the shutdown dose rate (SDDR) in fusion reactors. Accurate full-scale R2S calculations are impractical in fusion reactors because they require calculating space- and energy-dependent neutron fluxes everywhere inside the reactor. The use of global Monte Carlo variance reduction techniques was suggested for accelerating the R2S neutron transport calculation. However, the prohibitive computational costs of these approaches, which increase with the problem size and amount of shielding materials, inhibit their ability to accurately predict the SDDR in fusion energy systems using full-scale modeling of an entire fusion plant. This paper describes a novel hybrid Monte Carlo/deterministic methodology that uses the Consistent Adjoint Driven Importance Sampling (CADIS) method but focuses on multi-step shielding calculations. The Multi-Step CADIS (MS-CADIS) methodology speeds up the R2S neutron Monte Carlo calculation using an importance function that represents the neutron importance to the final SDDR. Using a simplified example, preliminary results showed that the use of MS-CADIS enhanced the efficiency of the neutron Monte Carlo simulation of an SDDR calculation by a factor of 550 compared to standard global variance reduction techniques, and that the efficiency enhancement compared to analog Monte Carlo is higher than a factor of 10,000

  13. Impact of Health Research Systems on Under-5 Mortality Rate: A Trend Analysis

    Directory of Open Access Journals (Sweden)

    Bahareh Yazdizadeh

    2017-07-01

    Full Text Available Background Between 1990 and 2015, under-5 mortality rate (U5MR declined by 53%, from an estimated rate of 91 deaths per 1000 live births to 43, globally. The aim of this study was to determine the share of health research systems in this decrease alongside other influential factors. Methods We used random effect regression models including the ‘random intercept’ and ‘random intercept and random slope’ models to analyze the panel data from 1990 to 2010. We selected the countries with U5MRs falling between the first and third quartiles in 1990. We used both the total articles (TA and the number of child-specific articles (CSA as a proxy of the health research system. In order to account for the impact of other factors, measles vaccination coverage (MVC (as a proxy of health system performance, gross domestic product (GDP, human development index (HDI, and corruption perception index (CPI (as proxies of development, were embedded in the model. Results Among all the models, ‘the random intercept and random slope models’ had lower residuals. The same variables of CSA, HDI, and time were significant and the coefficient of CSA was estimated at -0.17; meaning, with the addition of every 100 CSA, the rate of U5MR decreased by 17 per 1000 live births. Conclusion Although the number of CSA has contributed to the reduction of U5MR, the amount of its contribution is negligible compared to the countries’ development. We recommend entering different types of researches into the model separately in future research andincluding the variable of ‘exchange between knowledge generator and user.’

  14. Development of prediction system of dose equivalent rate around a package

    International Nuclear Information System (INIS)

    Nakao, Tetsuya; Minakami, Goro; Taniuchi, Hiroaki; Fujisawa, Kyosuke; Matsukawa, Yukio; Mimura, Shigemi.

    1993-01-01

    A new system is developed that can evaluate the radiation strength of the source in detail, on the basis of the irradiation history of each fuel assembly in a TN-12 or 12A package, and then to determine the best way to organize the assemblies in the package so that the dose equivalent rate around a package is kept to a minimum. This system for minimizing the danger of radiation for operators involved in packaging and transporting spent fuel was developed for personal computer use, to offer ease in handling and high adaptability. The data input is done in dialogue style, with a variety of check functions. In checks to verify the accuracy of the shielding calculation data in this system by comparing the calculated values with several kinds of measured values, the reliability of this new system has been shown to be very high. Since its high utility has been recognized, the system has already been put into use in actual transportation situations. (J.P.N.)

  15. Verification of the calculation program for brachytherapy planning system of high dose rate (PLATO)

    International Nuclear Information System (INIS)

    Almansa, J.; Alaman, C.; Perez-Alija, J.; Herrero, C.; Real, R. del; Ososrio, J. L.

    2011-01-01

    In our treatments are performed brachytherapy high dose rate since 2007. The procedures performed include gynecological intracavitary treatment and interstitial. The treatments are performed with a source of Ir-192 activity between 5 and 10 Ci such that small variations in treatment times can cause damage to the patient. In addition the Royal Decree 1566/1998 on Quality Criteria in radiotherapy establishes the need to verify the monitor units or treatment time in radiotherapy and brachytherapy. All this justifies the existence of a redundant system for brachytherapy dose calculation that can reveal any abnormality is present.

  16. Method and apparatus for controlling the flow rate of mercury in a flow system

    Science.gov (United States)

    Grossman, Mark W.; Speer, Richard

    1991-01-01

    A method for increasing the mercury flow rate to a photochemical mercury enrichment utilizing an entrainment system comprises the steps of passing a carrier gas over a pool of mercury maintained at a first temperature T1, wherein the carrier gas entrains mercury vapor; passing said mercury vapor entrained carrier gas to a second temperature zone T2 having temperature less than T1 to condense said entrained mercury vapor, thereby producing a saturated Hg condition in the carrier gas; and passing said saturated Hg carrier gas to said photochemical enrichment reactor.

  17. Differential neutrino rates and emissivities from the plasma process in astrophysical systems

    International Nuclear Information System (INIS)

    Ratkovic, Sasa; Iyer Dutta, Sharada; Prakash, Madappa

    2003-01-01

    The differential rates and emissivities of neutrino pairs from an equilibrium plasma are calculated for the wide range of density and temperature encountered in astrophysical systems. New analytical expressions are derived for the differential emissivities which yield total emissivities in full agreement with those previously calculated. The photon and plasmon pair production and absorption kernels in the source term of the Boltzmann equation for neutrino transport are provided. The appropriate Legendre coefficients of these kernels, in forms suitable for multi-group flux-limited diffusion schemes are also computed

  18. A network-based rating system and its resistance to bribery

    OpenAIRE

    Turrini, P; Grandi, U

    2016-01-01

    We study a rating system in which a set of individ- uals (e.g., the customers of a restaurant) evaluate a given service (e.g, the restaurant), with their ag- gregated opinion determining the probability of all individuals to use the service and thus its generated revenue. We explicitly model the influence relation by a social network, with individuals being influ- enced by the evaluation of their trusted peers. On top of that we allow a malicious service provider (e.g., the restaurant owne...

  19. A Comparative Study of Data Mining Algorithms for High Detection Rate in Intrusion Detection System

    Directory of Open Access Journals (Sweden)

    Nabeela Ashraf

    2018-01-01

    Full Text Available Due to the fast growth and tradition of the internet over the last decades, the network security problems are increasing vigorously. Humans can not handle the speed of processes and the huge amount of data required to handle network anomalies. Therefore, it needs substantial automation in both speed and accuracy. Intrusion Detection System is one of the approaches to recognize illegal access and rare attacks to secure networks. In this proposed paper, Naive Bayes, J48 and Random Forest classifiers are compared to compute the detection rate and accuracy of IDS. For experiments, the KDD_NSL dataset is used.

  20. Multi-rate cubature Kalman filter based data fusion method with residual compensation to adapt to sampling rate discrepancy in attitude measurement system.

    Science.gov (United States)

    Guo, Xiaoting; Sun, Changku; Wang, Peng

    2017-08-01

    This paper investigates the multi-rate inertial and vision data fusion problem in nonlinear attitude measurement systems, where the sampling rate of the inertial sensor is much faster than that of the vision sensor. To fully exploit the high frequency inertial data and obtain favorable fusion results, a multi-rate CKF (Cubature Kalman Filter) algorithm with estimated residual compensation is proposed in order to adapt to the problem of sampling rate discrepancy. During inter-sampling of slow observation data, observation noise can be regarded as infinite. The Kalman gain is unknown and approaches zero. The residual is also unknown. Therefore, the filter estimated state cannot be compensated. To obtain compensation at these moments, state error and residual formulas are modified when compared with the observation data available moments. Self-propagation equation of the state error is established to propagate the quantity from the moments with observation to the moments without observation. Besides, a multiplicative adjustment factor is introduced as Kalman gain, which acts on the residual. Then the filter estimated state can be compensated even when there are no visual observation data. The proposed method is tested and verified in a practical setup. Compared with multi-rate CKF without residual compensation and single-rate CKF, a significant improvement is obtained on attitude measurement by using the proposed multi-rate CKF with inter-sampling residual compensation. The experiment results with superior precision and reliability show the effectiveness of the proposed method.

  1. A high rate, low noise, x-ray silicon strip detector system

    International Nuclear Information System (INIS)

    Ludewigt, B.; Jaklevic, J.; Kipnis, I.; Rossington, C.; Spieler, H.

    1993-11-01

    An x-ray detector system, based on a silicon strip detector wire-bonded to a low noise charge-senstive amplifier integrated circuit, has been developed for synchrotron radiation experiments which require very high count rates and good energy resolution. Noise measurements and x-ray spectra were taken using a 6 mm long, 55 μm pitch strip detector in conjunction with a prototype 16-channel charge-sensitive preamplifier, both fabricated using standard 1.2 μm CMOS technology. The detector system currently achieves an energy resolution of 350 eV FWHM at 5.9 key, 2 μs peaking time, when cooled to -5 degree C

  2. Fault diagnosis for temperature, flow rate and pressure sensors in VAV systems using wavelet neural network

    Energy Technology Data Exchange (ETDEWEB)

    Du, Zhimin; Jin, Xinqiao; Yang, Yunyu [School of Mechanical Engineering, Shanghai Jiao Tong University, 800, Dongchuan Road, Shanghai (China)

    2009-09-15

    Wavelet neural network, the integration of wavelet analysis and neural network, is presented to diagnose the faults of sensors including temperature, flow rate and pressure in variable air volume (VAV) systems to ensure well capacity of energy conservation. Wavelet analysis is used to process the original data collected from the building automation first. With three-level wavelet decomposition, the series of characteristic information representing various operation conditions of the system are obtained. In addition, neural network is developed to diagnose the source of the fault. To improve the diagnosis efficiency, three data groups based on several physical models or balances are classified and constructed. Using the data decomposed by three-level wavelet, the neural network can be well trained and series of convergent networks are obtained. Finally, the new measurements to diagnose are similarly processed by wavelet. And the well-trained convergent neural networks are used to identify the operation condition and isolate the source of the fault. (author)

  3. THE USE OF ELECTRONIC JOURNALS IN SCORE RATING ACCOUNTING SYSTEM OF EDUCATIONAL ACHIEVEMENTS OF STUDENTS

    Directory of Open Access Journals (Sweden)

    И Н Куринин

    2016-12-01

    Full Text Available The article describes a method of using electronic journals as a tool for efficient organization of teacher’s practical work in conditions of computerization of educational process and the widespread implementation of credit-modular system of educational process organization and grade-rating system for basic educational programs proficiency examination. A version of the electronic journal designed by the authors and realized in the program MS Excel is also presented in the article. An example of a completed “Academic Progress” page of the university educational web portal is discussed. It contains a marked electronic student grade book section and the stated conditions and criteria for grades allocation, according to a 100-point scale.

  4. Automatic stress-relieving music recommendation system based on photoplethysmography-derived heart rate variability analysis.

    Science.gov (United States)

    Shin, Il-Hyung; Cha, Jaepyeong; Cheon, Gyeong Woo; Lee, Choonghee; Lee, Seung Yup; Yoon, Hyung-Jin; Kim, Hee Chan

    2014-01-01

    This paper presents an automatic stress-relieving music recommendation system (ASMRS) for individual music listeners. The ASMRS uses a portable, wireless photoplethysmography module with a finger-type sensor, and a program that translates heartbeat signals from the sensor to the stress index. The sympathovagal balance index (SVI) was calculated from heart rate variability to assess the user's stress levels while listening to music. Twenty-two healthy volunteers participated in the experiment. The results have shown that the participants' SVI values are highly correlated with their prespecified music preferences. The sensitivity and specificity of the favorable music classification also improved as the number of music repetitions increased to 20 times. Based on the SVI values, the system automatically recommends favorable music lists to relieve stress for individuals.

  5. Bit Error Rate Analysis for MC-CDMA Systems in Nakagami- Fading Channels

    Directory of Open Access Journals (Sweden)

    Li Zexian

    2004-01-01

    Full Text Available Multicarrier code division multiple access (MC-CDMA is a promising technique that combines orthogonal frequency division multiplexing (OFDM with CDMA. In this paper, based on an alternative expression for the -function, characteristic function and Gaussian approximation, we present a new practical technique for determining the bit error rate (BER of multiuser MC-CDMA systems in frequency-selective Nakagami- fading channels. The results are applicable to systems employing coherent demodulation with maximal ratio combining (MRC or equal gain combining (EGC. The analysis assumes that different subcarriers experience independent fading channels, which are not necessarily identically distributed. The final average BER is expressed in the form of a single finite range integral and an integrand composed of tabulated functions which can be easily computed numerically. The accuracy of the proposed approach is demonstrated with computer simulations.

  6. System care improves trauma outcome: patient care errors dominate reduced preventable death rate.

    Science.gov (United States)

    Thoburn, E; Norris, P; Flores, R; Goode, S; Rodriguez, E; Adams, V; Campbell, S; Albrink, M; Rosemurgy, A

    1993-01-01

    A review of 452 trauma deaths in Hillsborough County, Florida, in 1984 documented that 23% of non-CNS trauma deaths were preventable and occurred because of inadequate resuscitation or delay in proper surgical care. In late 1988 Hillsborough County organized a County Trauma Agency (HCTA) to coordinate trauma care among prehospital providers and state-designated trauma centers. The purpose of this study was to review county trauma deaths after the inception of the HCTA to determine the frequency of preventable deaths. 504 trauma deaths occurring between October 1989 and April 1991 were reviewed. Through committee review, 10 deaths were deemed preventable; 2 occurred outside the trauma system. Of the 10 deaths, 5 preventable deaths occurred late in severely injured patients. The preventable death rate has decreased to 7.0% with system care. The causes of preventable deaths have changed from delayed or inadequate intervention to postoperative care errors.

  7. 76 FR 70365 - Prevailing Rate Systems; Redefinition of the Austin, TX and Waco, TX, Appropriated Fund Federal...

    Science.gov (United States)

    2011-11-14

    ... 3206-AM50 Prevailing Rate Systems; Redefinition of the Austin, TX and Waco, TX, Appropriated Fund... the Federal Prevailing Rate Advisory Committee to best match the counties proposed for redefinition to... Prevailing Rate Advisory Committee (FPRAC), the national labor-management committee responsible for advising...

  8. 75 FR 39460 - Prevailing Rate Systems; Redefinition of the Chicago, IL; Fort Wayne-Marion, IN; Indianapolis, IN...

    Science.gov (United States)

    2010-07-09

    ...-AM21 Prevailing Rate Systems; Redefinition of the Chicago, IL; Fort Wayne-Marion, IN; Indianapolis, IN... wage area. These changes are based on recent consensus recommendations of the Federal Prevailing Rate... below. The Federal Prevailing Rate Advisory Committee (FPRAC), the national labor-management committee...

  9. Dynamic Optimization Design of Cranes Based on Human–Crane–Rail System Dynamics and Annoyance Rate

    Directory of Open Access Journals (Sweden)

    Yunsheng Xin

    2017-01-01

    Full Text Available The operators of overhead traveling cranes experience discomfort as a result of the vibrations of crane structures. These vibrations are produced by defects in the rails on which the cranes move. To improve the comfort of operators, a nine-degree-of-freedom (nine-DOF mathematical model of a “human–crane–rail” system was constructed. Based on the theoretical guidance provided in ISO 2631-1, an annoyance rate model was established, and quantization results were determined. A dynamic optimization design method for overhead traveling cranes is proposed. A particle swarm optimization (PSO algorithm was used to optimize the crane structural design, with the structure parameters as the basic variables, the annoyance rate model as the objective function, and the acceleration amplitude and displacement amplitude of the crane as the constraint conditions. The proposed model and method were used to optimize the design of a double-girder 100 t–28.5 m casting crane, and the optimal parameters are obtained. The results show that optimization decreases the human annoyance rate from 28.3% to 9.8% and the root mean square of the weighted acceleration of human vibration from 0.59 m/s2 to 0.38 m/s2. These results demonstrate the effectiveness and practical applicability of the models and method proposed in this paper.

  10. Portable Heart Rate Detector Based on Photoplethysmography with Android Programmable Devices for Ubiquitous Health Monitoring System

    Directory of Open Access Journals (Sweden)

    Chi Kin Lao

    2013-01-01

    Full Text Available In this paper, a miniature portable heart rate detector system is implemented by modern hardware ICs and simple sensor circuit with software executable on both PC and Android platform. The biosignal is first extracted via photoplethysmography (PPG principle into electric signal. Then a microprocessor is used to covert biosignal from analog to digital format, suitably for feeding into an RF module (nRF24L01 for RF transmission. On the receiver end, the computer and/or smart phone can analyze the data using a robust algorithm that can detect peaks of the PPG waveform, hence to calculating the heart rate. Some application software running on Windows and Android phone have been developed to display heart rate information and time domain waveform to users for health care monitoring. In the future, pure Bluetooth technology will be used for wireless personal communications instead of RF modules. At the same time, the data can be sent to computer console using existing available networks (3G, 4G, WiFi, etc. for health database logging purpose.

  11. Intersubject Differences in False Nonmatch Rates for a Fingerprint-Based Authentication System

    Directory of Open Access Journals (Sweden)

    Jeroen Breebaart

    2009-01-01

    Full Text Available The intersubject dependencies of false nonmatch rates were investigated for a minutiae-based biometric authentication process using single enrollment and verification measurements. A large number of genuine comparison scores were subjected to statistical inference tests that indicated that the number of false nonmatches depends on the subject and finger under test. This result was also observed if subjects associated with failures to enroll were excluded from the test set. The majority of the population (about 90% showed a false nonmatch rate that was considerably smaller than the average false nonmatch rate of the complete population. The remaining 10% could be characterized as “goats” due to their relatively high probability for a false nonmatch. The image quality reported by the template extraction module only weakly correlated with the genuine comparison scores. When multiple verification attempts were investigated, only a limited benefit was observed for “goats,” since the conditional probability for a false nonmatch given earlier nonsuccessful attempts increased with the number of attempts. These observations suggest that (1 there is a need for improved identification of “goats” during enrollment (e.g., using dedicated signal-driven analysis and classification methods and/or the use of multiple enrollment images and (2 there should be alternative means for identity verification in the biometric system under test in case of two subsequent false nonmatches.

  12. Trust on the Ratee: A Trust Management System for Social Internet of Vehicles

    Directory of Open Access Journals (Sweden)

    Fangyu Gai

    2017-01-01

    Full Text Available The integration of social networking concepts with Internet of Vehicles (IoV has led to the novel paradigm “Social Internet of Vehicles (SIoV,” which enables vehicles to establish social relationships autonomously to improve traffic conditions and service discovery. There is a growing requirement for effective trust management in the SIoV, considering the critical consequences of acting on misleading information spread by malicious nodes. However, most existing trust models are rater-based, where the reputation information of each node is stored in other nodes it has interacted with. This is not suitable for vehicular environment due to the ephemeral nature of the network. To fill this gap, we propose a Ratee-based Trust Management (RTM system, where each node stores its own reputation information rated by others during past transactions, and a credible CA server is introduced to ensure the integrality and the undeniability of the trust information. RTM is built based on the concept of SIoV, so that the relationships established between nodes can be used to increase the accuracy of the trustworthiness. Experimental results demonstrate that our scheme achieves faster information propagation and higher transaction success rate than the rater-based method, and the time cost when calculating trustworthiness can meet the demand of vehicular networks.

  13. Seasonal Variation of Infiltration Rates in a Managed Aquifer Recharge System: A Belgian Example

    Science.gov (United States)

    Samanta, S.; Sheng, Z.; Munster, C. L.; Houtte, E. V.

    2017-12-01

    Managed Aquifer Recharge (MAR) is a powerful tool in addressing water resources management issues. The Torreele water reuse facility is using MAR to address the problem of water sustainability in a coastal aquifer of Belgium. The Torreele MAR facility uses infiltration ponds to maintain the groundwater level and to prevent saltwater intrusion into the aquifer. The source of recharge is treated wastewater from the Torreele wastewater treatment plant (TWWTP) located 1.2 km inland. The TWWTP uses a state-of-the-art filtration mechanism with a combination of ultrafiltration (UF) and Reverse Osmosis (RO) techniques to assure that recharge water is of very high quality. Data collected at the Torreele MAR facility indicates reduced infiltration rates during the winter season when pond water temperatures vary from 1 to 10ºC. The proposed hypothesis for these lower infiltration rates may be a reduction in hydraulic conductivity due to changes in water viscosity. This study involves the determination of relationship between water temperature, infiltration rates, and hydraulic conductivity at the Torreele MAR facility. The results of this study will lead to an effective administration of the facility and provide an extensive understanding of the system.

  14. Performance and behaviour of chickens with different growing rate reared according to the organic system

    Directory of Open Access Journals (Sweden)

    Marcella Bernardini

    2010-01-01

    Full Text Available The performance and the behaviour of three different chicken strains, reared according to the EEC-Regulation 1804/1999  on organic system, were compared. The strains had very slow (Robusta maculata, slow (Kabir and fast (Ross growing  rates, respectively. The trial was carried out on 200 chickens (male and female per strain. Rearing lasted 81 days as  required by the EEC Regulation. At slaughter age, 20 birds per group were killed. Robusta maculata and Kabir chickens  showed more intense walking activity and better foraging aptitude; their antioxidant capacity was also superior. Ross  chickens had a good growth rate and feed conversion index, reaching an excellent body weight, but the mortality and  the culling rate were high indicating that fast-growing strains do not adapt well to organic production. Robusta macula-  ta showed the worst productive performance although the mortality was low and Kabir birds gave intermediate results.  The carcass traits were the best in Ross and the poorest in Robusta maculata. Male chickens were heavier and leaner  than females. 

  15. Analysis of two production inventory systems with buffer, retrials and different production rates

    Science.gov (United States)

    Jose, K. P.; Nair, Salini S.

    2017-09-01

    This paper considers the comparison of two ( {s,S} ) production inventory systems with retrials of unsatisfied customers. The time for producing and adding each item to the inventory is exponentially distributed with rate β. However, a production rate α β higher than β is used at the beginning of the production. The higher production rate will reduce customers' loss when inventory level approaches zero. The demand from customers is according to a Poisson process. Service times are exponentially distributed. Upon arrival, the customers enter into a buffer of finite capacity. An arriving customer, who finds the buffer full, moves to an orbit. They can retry from there and inter-retrial times are exponentially distributed. The two models differ in the capacity of the buffer. The aim is to find the minimum value of total cost by varying different parameters and compare the efficiency of the models. The optimum value of α corresponding to minimum total cost is an important evaluation. Matrix analytic method is used to find an algorithmic solution to the problem. We also provide several numerical or graphical illustrations.

  16. The Betting Odds Rating System: Using soccer forecasts to forecast soccer.

    Science.gov (United States)

    Wunderlich, Fabian; Memmert, Daniel

    2018-01-01

    Betting odds are frequently found to outperform mathematical models in sports related forecasting tasks, however the factors contributing to betting odds are not fully traceable and in contrast to rating-based forecasts no straightforward measure of team-specific quality is deducible from the betting odds. The present study investigates the approach of combining the methods of mathematical models and the information included in betting odds. A soccer forecasting model based on the well-known ELO rating system and taking advantage of betting odds as a source of information is presented. Data from almost 15.000 soccer matches (seasons 2007/2008 until 2016/2017) are used, including both domestic matches (English Premier League, German Bundesliga, Spanish Primera Division and Italian Serie A) and international matches (UEFA Champions League, UEFA Europe League). The novel betting odds based ELO model is shown to outperform classic ELO models, thus demonstrating that betting odds prior to a match contain more relevant information than the result of the match itself. It is shown how the novel model can help to gain valuable insights into the quality of soccer teams and its development over time, thus having a practical benefit in performance analysis. Moreover, it is argued that network based approaches might help in further improving rating and forecasting methods.

  17. Towards the VWO Annotation Service: a Success Story of the IMAGE RPI Expert Rating System

    Science.gov (United States)

    Reinisch, B. W.; Galkin, I. A.; Fung, S. F.; Benson, R. F.; Kozlov, A. V.; Khmyrov, G. M.; Garcia, L. N.

    2010-12-01

    Interpretation of Heliophysics wave data requires specialized knowledge of wave phenomena. Users of the virtual wave observatory (VWO) will greatly benefit from a data annotation service that will allow querying of data by phenomenon type, thus helping accomplish the VWO goal to make Heliophysics wave data searchable, understandable, and usable by the scientific community. Individual annotations can be sorted by phenomenon type and reduced into event lists (catalogs). However, in contrast to the event lists, annotation records allow a greater flexibility of collaborative management by more easily admitting operations of addition, revision, or deletion. They can therefore become the building blocks for an interactive Annotation Service with a suitable graphic user interface to the VWO middleware. The VWO Annotation Service vision is an interactive, collaborative sharing of domain expert knowledge with fellow scientists and students alike. An effective prototype of the VWO Annotation Service has been in operation at the University of Massachusetts Lowell since 2001. An expert rating system (ERS) was developed for annotating the IMAGE radio plasma imager (RPI) active sounding data containing 1.2 million plasmagrams. The RPI data analysts can use ERS to submit expert ratings of plasmagram features, such as presence of echo traces resulted from reflected RPI signals from distant plasma structures. Since its inception in 2001, the RPI ERS has accumulated 7351 expert plasmagram ratings in 16 phenomenon categories, together with free-text descriptions and other metadata. In addition to human expert ratings, the system holds 225,125 ratings submitted by the CORPRAL data prospecting software that employs a model of the human pre-attentive vision to select images potentially containing interesting features. The annotation records proved to be instrumental in a number of investigations where manual data exploration would have been prohibitively tedious and expensive

  18. 76 FR 2368 - Balance Power Systems, LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes...

    Science.gov (United States)

    2011-01-13

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. ER11-2331-000] Balance Power Systems, LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes Request for Blanket... proceeding of Balance Power Systems, LLC's application for market-based rate authority, with an accompanying...

  19. 78 FR 41013 - Medicare and Medicaid Programs; Home Health Prospective Payment System Rate Update for CY 2014...

    Science.gov (United States)

    2013-07-09

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Medicare & Medicaid Services 42 CFR Parts 431 [CMS-1450-CN] RIN 0938-AR52 Medicare and Medicaid Programs; Home Health Prospective Payment System Rate... period titled ``Medicare and Medicaid Programs; Home Health Prospective Payment System Rate Update for CY...

  20. Revising the IDEA Student Ratings of Instruction System 2002-2011 Data. IDEA Technical Report No. 18

    Science.gov (United States)

    Benton, Stephen L.; Li, Dan; Brown, Ron; Guo, Meixi; Sullivan, Patricia

    2015-01-01

    This report describes the processes undertaken to revise the IDEA Student Ratings of Instruction (SRI) system. The previous revision occurred in 1999, as described in IDEA Technical Report No. 11, "Revising the IDEA System for Obtaining Student Ratings of Instructors and Courses" (Hoyt, Chen, Pallett, & Gross, 1999). The procedures…