WorldWideScience

Sample records for ledged tapered beam

  1. Nonlinear Vibration of an Elastically Restrained Tapered Beam

    DEFF Research Database (Denmark)

    Karimpour, S; Ganji, S.S; Barari, Amin

    2012-01-01

    This paper presents the analytical simulation of an elastically restrained tapered cantilever beam using the energy balance method (EBM) and the iteration perturbation method (IPM). To assess the accuracy of solutions, we compare the results with the harmonic balance method (HBM). The obtained re...

  2. Coherent beam combining architectures for high power tapered laser arrays

    Science.gov (United States)

    Schimmel, G.; Janicot, S.; Hanna, M.; Decker, J.; Crump, P.; Erbert, G.; Witte, U.; Traub, M.; Georges, P.; Lucas-Leclin, G.

    2017-02-01

    Coherent beam combining (CBC) aims at increasing the spatial brightness of lasers. It consists in maintaining a constant phase relationship between different emitters, in order to combine them constructively in one single beam. We have investigated the CBC of an array of five individually-addressable high-power tapered laser diodes at λ = 976 nm, in two architectures: the first one utilizes the self-organization of the lasers in an interferometric extended-cavity, which ensures their mutual coherence; the second one relies on the injection of the emitters by a single-frequency laser diode. In both cases, the coherent combining of the phase-locked beams is ensured on the front side of the array by a transmission diffractive grating with 98% efficiency. The passive phase-locking of the laser bar is obtained up to 5 A (per emitter). An optimization algorithm is implemented to find the proper currents in the five ridge sections that ensured the maximum combined power on the front side. Under these conditions we achieve a maximum combined power of 7.5 W. In the active MOPA configuration, we can increase the currents in the tapered sections up to 6 A and get a combined power of 11.5 W, corresponding to a combining efficiency of 76%. It is limited by the beam quality of the tapered emitters and by fast phase fluctuations between emitters. Still, these results confirm the potential of CBC approaches with tapered lasers to provide a high-power and high-brightness beam, and compare with the current state-of-the-art with laser diodes.

  3. Spectral beam combining of a 980 nm tapered diode laser bar

    DEFF Research Database (Denmark)

    Vijayakumar, Deepak; Jensen, Ole Bjarlin; Ostendorf, Ralf

    2010-01-01

    We demonstrate spectral beam combining of a 980 nm tapered diode laser bar. The combined beam from 12 tapered emitters on the bar yielded an output power of 9.3 W at 30 A of operating current. An M2 value of 5.3 has been achieved along the slow axis. This value is close to that of a free running...... single tapered emitter on the bar at the same current level. The overall spectral beam combining efficiency was measured to be 63%....

  4. Flexural-torsional vibration of a tapered C-section beam

    Science.gov (United States)

    Dennis, Scott T.; Jones, Keith W.

    2017-04-01

    Previous studies have shown that numerical models of tapered thin-walled C-section beams based on a stepped or piecewise prismatic beam approximation are inaccurate regardless of the number of elements assumed in the discretization. Andrade recently addressed this problem by extending Vlasov beam theory to a tapered geometry resulting in new terms that vanish for the uniform beam. (See One-Dimensional Models for the Spatial Behaviour of Tapered Thin-Walled Bars with Open Cross-Sections: Static, Dynamic and Buckling Analyses, PhD Thesis, University of Coimbra, Portugal, 2012, https://estudogeral.sib.uc.pt) In this paper, we model the coupled bending-twisting vibration of a cantilevered tapered thin-walled C-section using a Galerkin approximation of Andrade's beam equations resulting in an 8-degree-of-freedom beam element. Experimental natural frequencies and mode shapes for 3 prismatic and 2 tapered channel beams are compared to model predictions. In addition, comparisons are made to detailed shell finite element models and exact solutions for the uniform beams to confirm the validity of the approach. Comparisons to the incorrect stepped model are also presented.

  5. Free Vibration and Stability of Axially Functionally Graded Tapered Euler-Bernoulli Beams

    Directory of Open Access Journals (Sweden)

    Ahmad Shahba

    2011-01-01

    Full Text Available Structural analysis of axially functionally graded tapered Euler-Bernoulli beams is studied using finite element method. A beam element is proposed which takes advantage of the shape functions of homogeneous uniform beam elements. The effects of varying cross-sectional dimensions and mechanical properties of the functionally graded material are included in the evaluation of structural matrices. This method could be used for beam elements with any distributions of mass density and modulus of elasticity with arbitrarily varying cross-sectional area. Assuming polynomial distributions of modulus of elasticity and mass density, the competency of the element is examined in stability analysis, free longitudinal vibration and free transverse vibration of double tapered beams with different boundary conditions and the convergence rate of the element is then investigated.

  6. Shaping ability of ProTaper Gold and ProTaper Universal files by using cone-beam computed tomography

    Directory of Open Access Journals (Sweden)

    Amr M Elnaghy

    2016-01-01

    Full Text Available Context: This study evaluated and compared the shaping ability of ProTaper Gold (PG (PG; Dentsply, Tulsa Dental Specialties, Tulsa, OK, USA system with ProTaper Universal (PU (PU; Dentsply Maillefer, Ballaigues, Switzerland using cone-beam computed tomography (CBCT imaging. Materials and Methods: Forty mesiobuccal canals of mandibular first molars with curvatures of 25−30° were divided into two experimental groups (n = 20 according to the rotary nickel-titanium (NiTi file system used in canal instrumentation as follows: Group PG and group PU. Canals were scanned before and after instrumentation using CBCT scanner to evaluate root canal transportation and centering ratio at 3, 5, and 7 mm from the apex and volumetric changes. Data were statistically analyzed using independent t-tests and the significance level was set at P 0.05. Conclusions: The PG and PU NiTi rotary systems showed similar root canal shaping abilities in the preparation of mesial canals of mandibular first molars.

  7. Tapered optical fiber tip probes based on focused ion beam-milled Fabry-Perot microcavities

    Science.gov (United States)

    André, Ricardo M.; Warren-Smith, Stephen C.; Becker, Martin; Dellith, Jan; Rothhardt, Manfred; Zibaii, M. I.; Latifi, H.; Marques, Manuel B.; Bartelt, Hartmut; Frazão, Orlando

    2016-09-01

    Focused ion beam technology is combined with dynamic chemical etching to create microcavities in tapered optical fiber tips, resulting in fiber probes for temperature and refractive index sensing. Dynamic chemical etching uses hydrofluoric acid and a syringe pump to etch standard optical fibers into cone structures called tapered fiber tips where the length, shape, and cone angle can be precisely controlled. On these tips, focused ion beam is used to mill several different types of Fabry-Perot microcavities. Two main cavity types are initially compared and then combined to form a third, complex cavity structure. In the first case, a gap is milled on the tapered fiber tip which allows the external medium to penetrate the light guiding region and thus presents sensitivity to external refractive index changes. In the second, two slots that function as mirrors are milled on the tip creating a silica cavity that is only sensitive to temperature changes. Finally, both cavities are combined on a single tapered fiber tip, resulting in a multi-cavity structure capable of discriminating between temperature and refractive index variations. This dual characterization is performed with the aid of a fast Fourier transform method to separate the contributions of each cavity and thus of temperature and refractive index. Ultimately, a tapered optical fiber tip probe with sub-standard dimensions containing a multi-cavity structure is projected, fabricated, characterized and applied as a sensing element for simultaneous temperature and refractive index discrimination.

  8. Wavelength beam combining of a 980-nm tapered diode laser bar in an external cavity

    DEFF Research Database (Denmark)

    Vijayakumar, Deepak; Jensen, Ole Bjarlin; Thestrup Nielsen, Birgitte

    2010-01-01

    . By adapting a bar geometry, the output power could be scaled even up to several tens of watts. Unfortunately, the high divergence which is a characteristic feature of the bar geometry could lead to a degradation of the overall beam quality of the laser bar. However, spectral beam combining is an effective...... solution for preserving the beam quality of the bar in the range of that of a single emitter and at the same time, enabling the power scaling. We report spectral beam combining applied to a 12 emitter tapered laser bar at 980 nm. The external cavity has been designed for a wavelength separation of 4.0 nm...

  9. Automated touch sensing in the mouse tapered beam test using Raspberry Pi.

    Science.gov (United States)

    Ardesch, Dirk Jan; Balbi, Matilde; Murphy, Timothy H

    2017-11-01

    Rodent models of neurological disease such as stroke are often characterized by motor deficits. One of the tests that are used to assess these motor deficits is the tapered beam test, which provides a sensitive measure of bilateral motor function based on foot faults (slips) made by a rodent traversing a gradually narrowing beam. However, manual frame-by-frame scoring of video recordings is necessary to obtain test results, which is time-consuming and prone to human rater bias. We present a cost-effective method for automated touch sensing in the tapered beam test. Capacitive touch sensors detect foot faults onto the beam through a layer of conductive paint, and results are processed and stored on a Raspberry Pi computer. Automated touch sensing using this method achieved high sensitivity (96.2%) as compared to 'gold standard' manual video scoring. Furthermore, it provided a reliable measure of lateralized motor deficits in mice with unilateral photothrombotic stroke: results indicated an increased number of contralesional foot faults for up to 6days after ischemia. The automated adaptation of the tapered beam test produces results immediately after each trial, without the need for labor-intensive post-hoc video scoring. It also increases objectivity of the data as it requires less experimenter involvement during analysis. Automated touch sensing may provide a useful adaptation to the existing tapered beam test in mice, while the simplicity of the hardware lends itself to potential further adaptations to related behavioral tests. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. High Efficiency Energy Extraction from a Relativistic Electron Beam in a Strongly Tapered Undulator

    Science.gov (United States)

    Sudar, N.; Musumeci, P.; Duris, J.; Gadjev, I.; Polyanskiy, M.; Pogorelsky, I.; Fedurin, M.; Swinson, C.; Kusche, K.; Babzien, M.; Gover, A.

    2016-10-01

    We present results of an experiment where, using a 200 GW CO2 laser seed, a 65 MeV electron beam was decelerated down to 35 MeV in a 54-cm-long strongly tapered helical magnetic undulator, extracting over 30% of the initial electron beam energy to coherent radiation. These results, supported by simulations of the radiation field evolution, demonstrate unparalleled electro-optical conversion efficiencies for a relativistic beam in an undulator field and represent an important step in the development of high peak and average power coherent radiation sources.

  11. High efficiency tapered free-electron lasers with a prebunched electron beam

    Science.gov (United States)

    Emma, C.; Sudar, N.; Musumeci, P.; Urbanowicz, A.; Pellegrini, C.

    2017-11-01

    In this paper we analyze the high gain, high efficiency tapered free-electron laser amplifier with a prebunched electron beam. Simple scaling laws are derived for the peak output power and extraction efficiency and verified using 1D simulations. These studies provide useful analytical expressions which highlight the benefits resulting from fine control of the initial conditions of the system, namely the initial electron beam bunching and input seed radiation. When time-dependent effects are included, the sideband instability is known to limit the radiation amplification due to particle detrapping. We discuss two different approaches to mitigate the sideband growth via 1-D time dependent simulations. We find that a more aggressive taper enabled by strong prebunching and a modulation of the resonance condition are both effective methods for suppressing the sideband instability growth rate.

  12. Second-Order Nonlinear Analysis of Steel Tapered Beams Subjected to Span Loading

    Directory of Open Access Journals (Sweden)

    Ali Hadidi

    2014-03-01

    Full Text Available A second-order elastic analysis of tapered steel members with I-shaped sections subjected to span distributed and concentrated loadings is developed. Fixed end forces and moments as well as exact stiffness matrix of tapered Timoshenko-Euler beam are obtained with exact geometrical properties of sections. The simultaneous action of bending moment, shear, and axial force including P−δ effects is also considered in the analysis. A computer code has been developed in MATLAB software using a power series method to solve governing second-order differential equation of equilibrium with variable coefficients for beams with distributed span loading. A generalized matrix condensation technique is then utilized for analysis of beams with concentrated span loadings. The accuracy and efficiency of the results of the proposed method are verified through comparing them to those obtained from other approaches such as finite element methods, which indicates the robustness and time saving of this method even for large scale frames with tapered members.

  13. 16 W output power by high-efficient spectral beam combining of DBR-tapered diode lasers

    DEFF Research Database (Denmark)

    Müller, André; Vijayakumar, Deepak; Jensen, Ole Bjarlin

    2011-01-01

    Up to 16 W output power has been obtained using spectral beam combining of two 1063 nm DBR-tapered diode lasers. Using a reflecting volume Bragg grating, a combining efficiency as high as 93.7% is achieved, resulting in a single beam with high spatial coherence. The result represents the highest...... output power achieved by spectral beam combining of two single element tapered diode lasers. Since spectral beam combining does not affect beam propagation parameters, M2-values of 1.8 (fast axis) and 3.3 (slow axis) match the M2- values of the laser with lowest spatial coherence. The principle...... of spectral beam combining used in our experiments can be expanded to combine more than two tapered diode lasers and hence it is expected that the output power may be increased even further in the future....

  14. 16 W output power by high-efficient spectral beam combining of DBR-tapered diode lasers.

    Science.gov (United States)

    Müller, André; Vijayakumar, Deepak; Jensen, Ole Bjarlin; Hasler, Karl-Heinz; Sumpf, Bernd; Erbert, Götz; Andersen, Peter E; Petersen, Paul Michael

    2011-01-17

    Up to 16 W output power has been obtained using spectral beam combining of two 1063 nm DBR-tapered diode lasers. Using a reflecting volume Bragg grating, a combining efficiency as high as 93.7% is achieved, resulting in a single beam with high spatial coherence. The result represents the highest output power achieved by spectral beam combining of two single element tapered diode lasers. Since spectral beam combining does not affect beam propagation parameters, M2-values of 1.8 (fast axis) and 3.3 (slow axis) match the M2-values of the laser with lowest spatial coherence. The principle of spectral beam combining used in our experiments can be expanded to combine more than two tapered diode lasers and hence it is expected that the output power may be increased even further in the future.

  15. Effects of hole tapering on cone-beam collimation for brain SPECT imaging

    International Nuclear Information System (INIS)

    Park, Mi-Ae; Kijewski, Marie Foley; Moore, Stephen C.

    2006-01-01

    New collimator manufacturing technologies, such as photoetching, electrical discharge machining, and stereolithography, expand the range of possible cone-beam collimator configurations. For example, it might now be possible for brain SPECT to make a short-focusing cone-beam collimator with tapered holes that increase in size with distance from the collimator surface; conventional lead-casting techniques produce holes of constant size and, consequently, varying septal thicknesses. Moreover, the changes in hole shape and loss of close packing due to focusing leads to thicker septa in the collimator periphery, especially for shorter focal lengths. We investigated the potential advantages of new cone-beam collimator manufacturing processes, and proposed a new design for very short focal-length collimators for brain SPECT imaging. We compared three cone-beam collimators, a conventional collimator manufactured using casting techniques (CC), a novel collimator with uniform hole sizes on the collimator surface and constant hole size through the collimator thickness (FC), and a novel collimator with uniform hole sizes and tapered holes (TC). We determined the resolution of each collimator analytically for focal lengths ranging from 20-50 cm, and adjusted the entrance hole sizes of FC and TC to equalize resolution of all collimators. Sensitivity was calculated at several locations by Monte Carlo simulation. Sensitivity was higher at all points for TC and FC than for CC, and higher for TC than for FC. The differences in sensitivity were larger for shorter focal lengths. For a point on the focal line at 10 cm in front of the collimator entrance surface, the sensitivity gain for TC compared to CC was 7% and 45% for focal lengths of 50 and 20 cm, respectively. The sensitivity gain for a 20-cm focal length, compared to CC, averaged over all locations, was 44% for TC and 23% for FC. We have shown that the new collimator designs made possible by new manufacturing techniques will

  16. Moment method analysis of linearly tapered slot antennas: Low loss components for switched beam radiometers

    Science.gov (United States)

    Koeksal, Adnan; Trew, Robert J.; Kauffman, J. Frank

    1992-01-01

    A Moment Method Model for the radiation pattern characterization of single Linearly Tapered Slot Antennas (LTSA) in air or on a dielectric substrate is developed. This characterization consists of: (1) finding the radiated far-fields of the antenna; (2) determining the E-Plane and H-Plane beamwidths and sidelobe levels; and (3) determining the D-Plane beamwidth and cross polarization levels, as antenna parameters length, height, taper angle, substrate thickness, and the relative substrate permittivity vary. The LTSA geometry does not lend itself to analytical solution with the given parameter ranges. Therefore, a computer modeling scheme and a code are necessary to analyze the problem. This necessity imposes some further objectives or requirements on the solution method (modeling) and tool (computer code). These may be listed as follows: (1) a good approximation to the real antenna geometry; and (2) feasible computer storage and time requirements. According to these requirements, the work is concentrated on the development of efficient modeling schemes for these type of problems and on reducing the central processing unit (CPU) time required from the computer code. A Method of Moments (MoM) code is developed for the analysis of LTSA's within the parameter ranges given.

  17. Trapped resonance modes at tapered SR masks in a beam pipe

    International Nuclear Information System (INIS)

    Sakanaka, Shogo.

    1995-04-01

    We report on the possibility that electromagnetic resonances arise at a certain configuration of SR (synchrotron radiation) masks installed in a beam pipe. Because such resonances can cause coupled-bunch instabilities, care should be taken to avoid a resonance structure or to damp the Q-values of the resonances. (author)

  18. Controlling nanowire emission profile using conical taper

    DEFF Research Database (Denmark)

    Gregersen, Niels; Nielsen, Torben Roland; Mørk, Jesper

    2008-01-01

    The influence of a conical taper on nanowire light emission is studied. For nanowires with divergent output beams, the introduction of tapers improves the emission profile and increase the collection efficiency of the detection optics.......The influence of a conical taper on nanowire light emission is studied. For nanowires with divergent output beams, the introduction of tapers improves the emission profile and increase the collection efficiency of the detection optics....

  19. Coupled tapering/uptapering of Thirring type soliton pair in nonlinear media

    Science.gov (United States)

    Prasad, Shraddha; Dutta, Manoj Kumar; Sarkar, Ram Krishna

    2018-03-01

    The paper investigates coupled tapering/uptapering of Thirring type soliton pair, employing Beam Propagation Method. It is seen that, the pair uptapers in presence of losses and tapers in presence of gain. When the first beam has gain and the second one has losses in the nonlinear medium, the second beam induces uptapering in the first beam, while, first beam induces tapering in the second beam. When the medium provides gain/losses to only one of the two beams, the beam undergoes tapering/uptapering and also induces tapering/uptapering to the other loss less beam; however, magnitude of tapering/uptapering are different.

  20. Theory of tapered laser cooling

    International Nuclear Information System (INIS)

    Okamoto, Hiromi; Wei, J.

    1998-01-01

    A theory of tapered laser cooling for fast circulating ion beams in a storage ring is constructed. The authors describe the fundamentals of this new cooling scheme, emphasizing that it might be the most promising way to beam crystallization. The cooling rates are analytically evaluated to study the ideal operating condition. They discuss the physical implication of the tapering factor of cooling laser, and show how to determine its optimum value. Molecular dynamics method is employed to demonstrate the validity of the present theory

  1. Development of micro-beam NRA for 3D-mapping of hydrogen distribution in solids: Application of tapered glass capillary to 6 MeV 15N ion

    International Nuclear Information System (INIS)

    Sekiba, D.; Yonemura, H.; Nebiki, T.; Wilde, M.; Ogura, S.; Yamashita, H.; Matsumoto, M.; Kasagi, J.; Iwamura, Y.; Itoh, T.; Matsuzaki, H.; Narusawa, T.; Fukutani, K.

    2008-01-01

    A micro-beam NRA system, by means of a resonant nuclear reaction 1 H( 15 N, αγ) 12 C, has been developed for the purpose of the 3D mapping of the hydrogen distribution in solids. To obtain the tens μm size of the beam spot, the combination of the newly proposed tapered glass capillary and a conventional quadrupole magnetic lens is employed. An Y patterned film on a substrate is prepared as an application of the developed system. The 6 MeV 15 N beam focused by glass capillaries down to 50 μm successfully shows the hydrogen distribution. The in-plane NRA profile implies that the beam emitted from the glass capillary outlet is parallel, although the original beam has a considerable divergence. The NRA measurements in the 10 3 Pa N 2 atmosphere due to the low gas conductance of the glass capillary is also demonstrated

  2. 77 FR 16674 - Establishment of the Wisconsin Ledge Viticultural Area

    Science.gov (United States)

    2012-03-22

    .... All of the comments expressed support for the proposed Wisconsin Ledge viticultural area. TTB... label reference on a wine that indicates or implies an origin other than the wine's true place of origin... or other term identified as being viticulturally significant in part 9 of the TTB regulations, at...

  3. Compact L-edge densitometer for uranium concentration assay

    International Nuclear Information System (INIS)

    Brooks, M.L.; Russo, P.A.; Sprinkle, J.K. Jr.

    1985-02-01

    A new L-edge densitometer has been designed around a compact, commercial x-ray generator weighing less than 5 kg. The dc generator x-ray spectrum was tailored to produce a continuum of x-ray energies from 14 to 20 keV. The x rays were transmitted through uranium reference solutions, and the measured transmissions near the uranium L/sub III/-absorption edge were used to compute the uranium concentration assay result. The range of uranium concentrations in the reference solutions included 5 to 50 g/l. In this concentration range, the assay uncertainty for short count times and the flatness of the specific assay response were better than 0.5%. Thus, the precision and accuracy of this compact densitometer are equal to those demonstrated previously for the L-edge technique. The compact dimensions and optimized transmission geometry increase the practicality, versatility, and range of the L-edge applications. 12 references, 12 figures, 4 tables

  4. An Exact Analytical Solution to Exponentially Tapered Piezoelectric Energy Harvester

    Directory of Open Access Journals (Sweden)

    H. Salmani

    2015-01-01

    Full Text Available It has been proven that tapering the piezoelectric beam through its length optimizes the power extracted from vibration based energy harvesting. This phenomenon has been investigated by some researchers using semianalytical, finite element and experimental methods. In this paper, an exact analytical solution is presented to calculate the power generated from vibration of exponentially tapered unimorph and bimorph with series and parallel connections. The mass normalized mode shapes of the exponentially tapered piezoelectric beam with tip mass are implemented to transfer the proposed electromechanical coupled equations into modal coordinates. The steady states harmonic solution results are verified both numerically and experimentally. Results show that there exist values for tapering parameter and electric resistance in a way that the output power per mass of the energy harvester will be maximized. Moreover it is concluded that the electric resistance must be higher than a specified value for gaining more power by tapering the beam.

  5. Tapered structure construction

    Science.gov (United States)

    Smith, Eric D.; Takata, Rosalind K.; Slocum, Alexander H.; Nayfeh, Samir A.

    2016-04-05

    Feeding stock used to form a tapered structure into a curving device such that each point on the stock undergoes rotational motion about a peak location of the tapered structure; and the stock meets a predecessor portion of stock along one or more adjacent edges.

  6. Tapered ZnO Whiskers: {hkil}-Specific Mosaic Twinning VLS Growth from a Partially Molten Bottom Source

    Directory of Open Access Journals (Sweden)

    Chen Shuei-Yuan

    2009-01-01

    Full Text Available Abstract Zn particulates overlaid with wurtzite (W-type ZnO condensates having nearly orthogonal and facets were found to self-catalyze unusual tapered W-ZnO whiskers upon isothermal atmospheric annealing, i.e., thermal oxidation, at 600 °C. Analytical electron microscopic observations indicated that such whiskers formed tapered slabs having mosaic and twinned domains. The tapered whiskers can be rationalized by an alternative vapor–liquid–solid growth, i.e., {hkil}-specific coalescence twinning growth from the ZnO condensates taking advantage of a partially molten bottom source of Zn and the adsorption of atoms at the whisker tips and ledges under the influence of capillarity effect. The tapered whiskers having strong photoluminescence at 391 nm and with a considerable flexibility could have potential applications.

  7. Controlling the emission profile of a nanowire with a conical taper

    DEFF Research Database (Denmark)

    Gregersen, Niels; Nielsen, Torben Roland; Claudon, J.

    2008-01-01

    The influence of a tapering on nanowire light-emission profiles is studied. We show that, for nanowires with divergent output beams, the introduction of a conical tapering with a small opening angle reduces the beam divergence and increases transmission. This results in a dramatic increase in the...... in the collection efficiency of the detection optics. For a realistic tapering and a modest NA, the collection efficiency is enhanced by more than a factor of 2. This improvement is ensured by the adiabatic expansion of the guided mode in the tapering....

  8. Do Stem Taper Microgrooves Influence Taper Corrosion in Total Hip Arthroplasty? A Matched Cohort Retrieval Study.

    Science.gov (United States)

    Arnholt, Christina M; MacDonald, Daniel W; Underwood, Richard J; Guyer, Eric P; Rimnac, Clare M; Kurtz, Steven M; Mont, Michael A; Klein, Gregg R; Lee, Gwo-Chin; Chen, Antonia F; Hamlin, Brian R; Cates, Harold E; Malkani, Arthur L; Kraay, Matthew J

    2017-04-01

    Previous studies identified imprinting of the stem morphology onto the interior head bore, leading researchers to hypothesize an influence of taper topography on mechanically assisted crevice corrosion. The purpose of this study was to analyze whether microgrooved stem tapers result in greater fretting corrosion damage than smooth stem tapers. A matched cohort of 120 retrieved head-stem pairs from metal-on-polyethylene bearings was created controlling for implantation time, flexural rigidity, apparent length of engagement, and head size. There were 2 groups of 60 heads each, mated with either smooth or microgrooved stem tapers. A high-precision roundness machine was used to measure and categorize the surface morphology. Fretting corrosion damage at the head-neck junction was characterized using the Higgs-Goldberg scoring method. Fourteen of the most damaged heads were analyzed for the maximum depth of material loss and focused ion beam cross-sectioned to view oxide and base metal. Fretting corrosion damage was not different between the 2 cohorts at the femoral head (P = .14, Mann-Whitney) or stem tapers (P = .35). There was no difference in the maximum depths of material loss between the cohorts (P = .71). Cross-sectioning revealed contact damage, signs of micro-motion, and chromium-rich oxide layers in both cohorts. Microgroove imprinting did not appear to have a different effect on the fretting corrosion behavior. The results of this matched cohort retrieval study do not support the hypothesis that taper surfaces with microgrooved stems exhibit increased in vivo fretting corrosion damage or material release. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. High-power green light generation by second harmonic generation of single-frequency tapered diode lasers

    DEFF Research Database (Denmark)

    Jensen, Ole Bjarlin; Andersen, Peter E.; Sumpf, Bernd

    2010-01-01

    laser emits in excess of 9 W single-frequency output power with a good beam quality. The output from the tapered diode laser is frequency doubled using periodically poled MgO:LiNbO3. We investigate the modulation potential of the green light and improve the modulation depth from 1:4 to 1:50.......We demonstrate the generation of high power (>1.5W) and single-frequency green light by single-pass second harmonic generation of a high power tapered diode laser. The tapered diode laser consists of a DBR grating for wavelength selectivity, a ridge section and a tapered section. The DBR tapered...

  10. Terahertz field imaging inside tapered parallel plate waveguides

    DEFF Research Database (Denmark)

    Iwaszczuk, Krzysztof; Andryieuski, Andrei; Lavrinenko, Andrei

    We present a non-invasive broadband air photonic method of terahertz field imaging inside a tapered parallel plate waveguide. The method is based on the terahertz-enhanced second harmonic generation of the fundamental laser beam in an external electric field. We also demonstrate the direct...

  11. Modeling and multidimensional optimization of a tapered free electron laser

    Directory of Open Access Journals (Sweden)

    Y. Jiao

    2012-05-01

    Full Text Available Energy extraction efficiency of a free electron laser (FEL can be greatly increased using a tapered undulator and self-seeding. However, the extraction rate is limited by various effects that eventually lead to saturation of the peak intensity and power. To better understand these effects, we develop a model extending the Kroll-Morton-Rosenbluth, one-dimensional theory to include the physics of diffraction, optical guiding, and radially resolved particle trapping. The predictions of the model agree well with that of the GENESIS single-frequency numerical simulations. In particular, we discuss the evolution of the electron-radiation interaction along the tapered undulator and show that the decreasing of refractive guiding is the major cause of the efficiency reduction, particle detrapping, and then saturation of the radiation power. With this understanding, we develop a multidimensional optimization scheme based on GENESIS simulations to increase the energy extraction efficiency via an improved taper profile and variation in electron beam radius. We present optimization results for hard x-ray tapered FELs, and the dependence of the maximum extractable radiation power on various parameters of the initial electron beam, radiation field, and the undulator system. We also study the effect of the sideband growth in a tapered FEL. Such growth induces increased particle detrapping and thus decreased refractive guiding that together strongly limit the overall energy extraction efficiency.

  12. 76 FR 63852 - Proposed Establishment of the Wisconsin Ledge Viticultural Area

    Science.gov (United States)

    2011-10-14

    ... than the surrounding land, moderating the summer mean maximum and winter mean minimum temperatures in... degree Fahrenheit that a day's mean temperature is above 50 degrees, the minimum temperature required for... adopted as a final rule, wine bottlers using ``Wisconsin Ledge'' in a brand name, including a trademark...

  13. Rapid inversion: running animals and robots swing like a pendulum under ledges.

    Directory of Open Access Journals (Sweden)

    Jean-Michel Mongeau

    Full Text Available Escaping from predators often demands that animals rapidly negotiate complex environments. The smallest animals attain relatively fast speeds with high frequency leg cycling, wing flapping or body undulations, but absolute speeds are slow compared to larger animals. Instead, small animals benefit from the advantages of enhanced maneuverability in part due to scaling. Here, we report a novel behavior in small, legged runners that may facilitate their escape by disappearance from predators. We video recorded cockroaches and geckos rapidly running up an incline toward a ledge, digitized their motion and created a simple model to generalize the behavior. Both species ran rapidly at 12-15 body lengths-per-second toward the ledge without braking, dove off the ledge, attached their feet by claws like a grappling hook, and used a pendulum-like motion that can exceed one meter-per-second to swing around to an inverted position under the ledge, out of sight. We discovered geckos in Southeast Asia can execute this escape behavior in the field. Quantification of these acrobatic behaviors provides biological inspiration toward the design of small, highly mobile search-and-rescue robots that can assist us during natural and human-made disasters. We report the first steps toward this new capability in a small, hexapedal robot.

  14. Rapid Inversion: Running Animals and Robots Swing like a Pendulum under Ledges

    Science.gov (United States)

    Mongeau, Jean-Michel; McRae, Brian; Jusufi, Ardian; Birkmeyer, Paul; Hoover, Aaron M.; Fearing, Ronald; Full, Robert J.

    2012-01-01

    Escaping from predators often demands that animals rapidly negotiate complex environments. The smallest animals attain relatively fast speeds with high frequency leg cycling, wing flapping or body undulations, but absolute speeds are slow compared to larger animals. Instead, small animals benefit from the advantages of enhanced maneuverability in part due to scaling. Here, we report a novel behavior in small, legged runners that may facilitate their escape by disappearance from predators. We video recorded cockroaches and geckos rapidly running up an incline toward a ledge, digitized their motion and created a simple model to generalize the behavior. Both species ran rapidly at 12–15 body lengths-per-second toward the ledge without braking, dove off the ledge, attached their feet by claws like a grappling hook, and used a pendulum-like motion that can exceed one meter-per-second to swing around to an inverted position under the ledge, out of sight. We discovered geckos in Southeast Asia can execute this escape behavior in the field. Quantification of these acrobatic behaviors provides biological inspiration toward the design of small, highly mobile search-and-rescue robots that can assist us during natural and human-made disasters. We report the first steps toward this new capability in a small, hexapedal robot. PMID:22701594

  15. Spectral narrowing of a 980 nm tapered diode laser bar

    DEFF Research Database (Denmark)

    Vijayakumar, Deepak; Jensen, Ole Bjarlin; Lucas Leclin, Gaëlle

    2011-01-01

    in wavelength specific applications and hence, it is vital to stabilize the emission spectrum of these devices. In our experiment, we describe the wavelength narrowing of a 12 element 980 nm tapered diode laser bar using a simple Littman configuration. The tapered laser bar which suffered from a big smile has...... been "smile corrected" using individual phase masks for each emitter. The external cavity consists of the laser bar, both fast and slow axis micro collimators, smile correcting phase mask, 6.5x beam expanding lens combination, a 1200 lines/mm reflecting grating with 85% efficiency in the first order...

  16. Automated on-line L-edge measurement of SNM concentration for near-real-time accounting

    International Nuclear Information System (INIS)

    Russo, P.A.; Marks, T. Jr.; Stephens, M.M.; Baker, A.L.; Cobb, D.D.

    1982-09-01

    An L-edge densitometer has been modified, tested, and demonstrated for on-line assay of special nuclear material concentration in flowing solution streams. The demonstration was part of a larger demonstration of near-real-time nuclear materials accounting during a continuous, week-long, cold operation of the Barnwell facility. The L-edge data were automatically analyzed and the results were transmitted to the materials accounting computer once every 5.5 min for the duration of the cold run. This report compares the results of the L-edge analyses with the delayed results obtained from destructive analysis of samples withdrawn from the same process line. Comparisons are also made with the results obtained in near real time from an automated process control instrument installed in series with the L-edge densitometer. The performance of the L-edge instrument was reliable throughout the continuous operation. The assay precision was consistent with that predicted by the counting statistics of the measurement. The results of the L-edge assays show good agreement with those of the destructive assays. A gradually varying discrepancy (of a few percent) between the L-edge and the process control results remains unexplained

  17. The wild tapered block bootstrap

    DEFF Research Database (Denmark)

    Hounyo, Ulrich

    -based method in terms of asymptotic accuracy of variance estimation and distribution approximation. For stationary time series, the asymptotic validity, and the favorable bias properties of the new bootstrap method are shown in two important cases: smooth functions of means, and M-estimators. The first......-order asymptotic validity of the tapered block bootstrap as well as the wild tapered block bootstrap approximation to the actual distribution of the sample mean is also established when data are assumed to satisfy a near epoch dependent condition. The consistency of the bootstrap variance estimator for the sample......In this paper, a new resampling procedure, called the wild tapered block bootstrap, is introduced as a means of calculating standard errors of estimators and constructing confidence regions for parameters based on dependent heterogeneous data. The method consists in tapering each overlapping block...

  18. Electromechanical modelling of tapered ionic polymer metal composites transducers

    Directory of Open Access Journals (Sweden)

    Rakesha Chandra Dash

    2016-09-01

    Full Text Available Ionic polymer metal composites (IPMCs are relatively new smart materials that exhibit a bidirectional electromechanical coupling. IPMCs have large number of important engineering applications such as micro robotics, biomedical devices, biomimetic robotics etc. This paper presents a comparison between tapered and uniform cantilevered Nafion based IPMCs transducer. Electromechanical modelling is done for the tapered beam. Thickness can be varied according to the requirement of force and deflection. Numerical results pertaining to the force and deflection characteristics of both type IPMCs transducer are obtained. It is shown that the desired amount of force and deflections for tapered IPMCs can be achieved for a given voltage. Different fixed end (t0 and free end (t1 thickness values have been taken to justify the results using MATLAB.

  19. Theoretical modelling of the ionospheric F1-ledge, part 2: Characteristics points

    International Nuclear Information System (INIS)

    Zhang Shunrong; Radicella, S.M.; Huang Xinyu

    1996-01-01

    Ionospheric characteristics relevant to the F1-ledge representation are investigated by using a theoretical ionospheric model and digisonde data. Results indicate that the altitude of the maximum gradient of the electron density with height (base point) is consistent with the height of half maximum density by night, and differences of about 20 km can be seen by day when an intermediate layer appears with the former always higher. It is also pointed out that electron density is particularly sensitive to dynamic processes at that height, where there is no photochemical equilibrium although the photoionization and the chemical loss of the oxygen ions are of the same order of magnitude. The fact that the base point carries information about both F2- and F1-layers suggests a possible use of the parameter in bottom side ionospheric modelling. As the occurrence of the minimum variability of electron density found experimentally in the F1-ledge is concerned, large variabilities of dynamic transport increasing from the F1-ledge height up are considered to be the main cause of the increasing variability with height. Changes due to photoionization and chemical reactions, which increase also with height but with a less degree in the molecular ions dominated region, are considered responsible for the slight variability observed in the upper E region until the minimum is reached at F1 heights. (author). 21 refs, 7 figs

  20. Numerical modeling of tapered undulators

    International Nuclear Information System (INIS)

    Boyanov, B.I.; Bunker, G.; Lee, J.M.; Morrison, T.I.

    1994-01-01

    Tapered-undulator radiation will be used in at least one of the third generation synchrotron sources. While the spectral and angular characteristics of the radiation have been calculated for some specific configurations, the effects of tapering on the spectrum are still not well characterized. In this paper we have used an FFT-based method to calculate the spectral and angular distributions of the radiation from a tapered undulator with vertically-polarized magnetic field. The effect of tapering on the horizontal symmetry of the angular distribution of the radiation is investigated. A simple expression for the presence or absence of horizontal reflection symmetry as a function of the undulator parameters is derived. We have shown that for APS-type undulators and energies as high as 25 keV the radiation may be expected to exhibit horizontal reflection symmetry for observation angles up to 200 μrad. Our calculations are in agreement with recent measurements of the on-axis brightness of the prototype APS-CHESS undulator operated in the tapered configuration, and with results from well-established non-FFT programs. (orig.)

  1. Fiber taper characterization by optical backscattering reflectometry.

    Science.gov (United States)

    Lai, Yu-Hung; Yang, Ki Youl; Suh, Myoung-Gyun; Vahala, Kerry J

    2017-09-18

    Fiber tapers provide a way to rapidly measure the spectra of many types of optical microcavities. Proper fabrication of the taper ensures that its width varies sufficiently slowly (adiabatically) along the length of the taper so as to maintain single spatial mode propagation. This is usually accomplished by monitoring the spectral transmission through the taper. In addition to this characterization method it is also helpful to know the taper width versus length. By developing a model of optical backscattering within the fiber taper, it is possible to use backscatter measurements to characterize the taper width versus length. The model uses the concept of a local taper numerical aperture to accurately account for varying backscatter collection along the length of the taper. In addition to taper profile information, the backscatter reflectometry method delineates locations along the taper where fluctuations in fiber core refractive index, cladding refractive index, and taper surface roughness each provide the dominant source of backscattering. Rayleigh backscattering coefficients are also extracted by fitting the data with the model and are consistent with the fiber manufacturer's datasheet. The optical backscattering reflectometer is also used to observe defects resulting from microcracks and surface contamination. All of this information can be obtained before the taper is removed from its fabrication apparatus. The backscattering method should also be prove useful for characterization of nanofibers.

  2. Analysis of the enhanced coupling efficiency for different profile curves of special optical taper

    Science.gov (United States)

    Gao, Fei-long; Fu, Xing-hu; Fu, Guang-wei; Bi, Wei-hong

    2014-07-01

    For enhancing the coupling efficiency between the beam and the photodiode, a special optical taper is proposed for receiving optical signal. Based on the circular symmetric structure of special optical taper, the profile curve equations of it are deduced, including the trigonometric function type, parabolic type and exponential type. Moreover, the coupling efficiencies for special optical tapers with different profile curves are studied. The relationships of incident position, incident angle and coupling efficiency are analyzed. Finally, the comparison of coupling efficiency analytical results is also given.

  3. Taper Preparation Variability Compared to Current Taper Standards Using Computed Tomography

    Directory of Open Access Journals (Sweden)

    Richard Gergi

    2012-01-01

    Full Text Available Introduction. The purpose of this study was to compare the taper variation in root canal preparations among Twisted Files and PathFiles-ProTaper .08 tapered rotary files to current standards. Methods. 60 root canals with severe angle of curvature (between 25∘ and 35∘ and short radius (<10 mm were selected. The canals were divided randomly into two groups of 30 each. After preparation with Twisted Files and PathFiles-ProTaper to size 25 taper .08, the diameter was measured using computed tomography (CT at 1, 3, and 16 mm. Canal taper preparation was calculated at the apical third and at the middle-cervical third. Results. Of the 2 file systems, both fell within the ±.05 taper variability. All preparations demonstrated variability when compared to the nominal taper .08. In the apical third, mean taper was significantly different between TF and PathFiles-ProTaper ( value < 0.0001; independent -test. Mean Taper was significantly higher with PathFile-ProTaper. In the middle-cervical third, mean Taper was significantly higher with TF ( value = 0.015; independent -test. Conclusion. Taper preparations of the investigated size 25 taper .08 were favorable but different from the nominal taper.

  4. Characterization of heterogeneous nickel sites in CO dehydrogenase from Clostridium thermoaceticum by nickel L-edge x-ray spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ralston, C.Y. [Univ. of California, Davis, CA (United States); Kumar, M.; Ragsdale, S.W. [Univ. of Nebraska, Lincoln, NE (United States)] [and others

    1997-04-01

    L-edge x-ray absorption spectroscopy (XAS) is a useful spectroscopic technique for determining the electronic state of transition metals. For first row transition metals, the L-edge represents a transition from 2p core levels to 3d valence levels. Coulomb and exchange interactions between the core hole and 3d valence electrons make the L-edge sensitive to the number and configuration of 3d electrons, hence to the metal spin state and oxidation state. The authors have used L-edge XAS to characterize the Ni sites in the carbon monoxide dehydrogenase (CODH) enzyme from Clostridium thermoaceticum. This CODH catalyzes both CO oxidation and acetyl-CoA synthesis at two Ni and Fe containing centers, C and A, respectively. Since the enzyme exhibits complex EPR signals that never integrate to one spin per Ni, there is evidence for heterogeneity in the types of Ni present. The Ni L-edge protein spectra were recorded at ALS beamline 9.3.2. The photon energy resolutions used for protein samples and for Ni model compound spectra were 350 and 270 meV respectively. During data collection the sample chamber was maintained at less than 5{times}10{sup {minus}9} Torr using a helium cryopump. Model compound spectra were measured using total electron yield detection, while protein spectra were recorded using fluorescence detection with a windowless 13-element germanium detector, and were calibrated using the total electron yield spectrum of NiF{sub 2} or NiO. Each protein spectrum presented represents the sum of approximately 40 15-minute scans. The authors have found that by using L-edge XAS they are able to distinguish between different spin and oxidation states of Ni compounds. They have used this result to characterize the Ni containing CODH protein in various states. The L-edge spectra are consistent with other results showing that when CODH is reacted with CO, the metal centers undergo reduction.

  5. Thermal Conductivity of Compounds Present in the Side Ledge in Aluminium Electrolysis Cells

    Science.gov (United States)

    Gheribi, Aïmen E.; Chartrand, Patrice

    2017-11-01

    This paper presents a database for the temperature-dependent thermal conductivity of compounds potentially present in the side ledge formed in aluminium electrolysis cells, between the molten electrolyte used to dissolve the alumina and the side wall. The database is given in the form of an analytical model with sets of parameters for each compound. To determine the model parameters, we considered a robust optimisation approach based on reliable models derived from fundamental physics. Where data are missing, first-principles calculations are utilized to estimate the parameters directly. For all compounds for which data are available, the model's predictions are found to be in very good agreement with reported experimental data.

  6. Identification of the Procedural Accidents During Root Canal Preparation Using Digital Intraoral Radiography and Cone Beam Computed Tomography

    OpenAIRE

    Csinszka K.-Ivácson A.-; Maria Monea Adriana; Monica Monea; Mihai Pop; Angela Borda

    2016-01-01

    Crown or root perforation, ledge formation, fractured instruments and perforation of the roots are the most important accidents which appear during endodontic therapy. Our objective was to evaluate the value of digital intraoral periapical radiographs compared to cone beam computed tomography images (CBCT) used to diagnose some procedural accidents. Material and methods: Eleven extracted molars were used in this study. A total of 18 perforations and 13 ledges were created artifically and 10 i...

  7. The Tapering Practices of Strongman Athletes.

    Science.gov (United States)

    Winwood, P W; Dudson, M K; Wilson, D; Mclaren-Harrison, J K H; Redjkins, V; Pritchard, H J; Keogh, J W L

    2018-01-24

    This study provides the first empirical evidence of how strongman athletes taper for strongman competitions. Strongman athletes (n=454) (mean ±SD: 33.2 ±8.0y, 178.1 ±10.6cm, 108.6 ±27.9kg, 12.6 ±8.9y general resistance training, 5.3 ±5.0y strongman implement training) completed a self-reported 4-page internet survey on tapering practices. Analysis by gender (male and female), age (≤ 30 and >30y), body mass (≤ 105 and >105kg) and competitive standard (local/regional amateur, national amateur and professional) was conducted. Eighty seven percent (n=396) of strongman athletes reported they used a taper. Athletes stated their typical taper length was 8.6 ±5.0 days, with the step taper the most commonly performed taper (52%). Training volume decreased during the taper by 45.5 ±12.9% and all training ceased 3.9 ±1.8 days out from competition. Typically, athletes reported training frequency and training duration stayed the same or decreased and training intensity decreased to around 50% in the last week. Athletes generally stated that; tapering was performed to achieve recovery, rest and peak performance; the deadlift, yoke walk and stone lifts/work took longer to recover from than other lifts; assistance exercises were reduced or removed in the taper; massage, foam rolling, nutritional changes and static stretching were strategies utilized in the taper; and, poor tapering occurred when athletes trained too heavy/hard or had too short a taper. This data will assist strongman athletes and coaches in the optimization of tapering variables leading to more peak performances. Future research could investigate the priming and pre-activation strategies strongman athletes utilize on competition day.

  8. Implementation of rectangular slit-inserted ultra-wideband tapered slot antenna.

    Science.gov (United States)

    Kim, Sun-Woong; Choi, Dong-You

    2016-01-01

    In this paper, a tapered slot antenna capable of ultra-wideband communication was designed. In the proposed antenna, rectangular slits were inserted to enhance the bandwidth and reduce the area of the antenna. The rectangular slit-inserted tapered slot antenna operated at a bandwidth of 8.45 GHz, and the bandwidth improved upon the basic tapered slot antenna by 4.72 GHz. The radiation pattern of the antenna was suitable for location recognition in a certain direction owing to an appropriate 3 dB beam width. The antenna gain was analyzed within the proposed bandwidth, and the highest gain characteristic at 7.55 dBi was exhibited at a 5-GHz band. The simulation and measurement results of the proposed tapered slot antenna were similar.

  9. A New Damped and Tapered Accelerating Structure for CLIC

    CERN Document Server

    Raguin, J Y; Syratchev, I V; Wilson, Ian H; Wuensch, Walter

    2002-01-01

    The main performance limits when designing accelerating structures for the Compact Linear Collider (CLIC) for an average accelerating gradient above 100 MV/m are electrical breakdown and material fatigue caused by pulsed surface heating. In addition, for stable beam operation, the structures should have low short-range transverse wakefields and much-reduced transverse and longitudinal long-range wakefields. Two damped and tapered accelerating structures have been designed. The first has an accelerating gradient of 112 MV/m with the surface electrical field limited to 300 MV/m and the maximum temperature increase limited to 100°C. The second, with an accelerating gradient of 150 MV/m, has a peak surface electrical field of 392 MV/m and a maximum temperature increase of 167°C. Innovations to the cell and damping waveguide geometry and to the tapering of the structures are presented, and possible further improvements are proposed.

  10. Gaussian Filtering with Tapered Oil-Filled Photonic Bandgap Fibers

    DEFF Research Database (Denmark)

    Brunetti, Anna Chiara; Scolari, Lara; Weirich, Johannes

    2008-01-01

    A tunable Gaussian filter based on a tapered oil-filled photonic crystal fiber is demonstrated. The filter is centered at X=1364nm with a bandwidth (FWHM) of 237nm. Tunability is achieved by changing the temperature of the filter. A shift of 210nm of the central wavelength has been observed by in...... by increasing the temperature from 25°C to 100°C. The measurements are compared to a simulated spectrum obtained by means of a vectorial Beam Propagation Method model....

  11. Truncated acoustic black hole structure with the optimized tapering shape and damping coating

    DEFF Research Database (Denmark)

    Ih, Jeong-Guon; Kim, Miseong; Lee, Ik Jin

    2016-01-01

    The acoustic black hole (ABH) structure can be an option as a vibration damper by providing a tapered wedge at the end of a beam or plate. However, not much work has been done on design to yield an effective ABH design for such a plate. We attempt to optimize the shape of the ABH to effectively...

  12. Comparative study of ProTaper gold, reciproc, and ProTaper universal for root canal preparation in severely curved root canals

    Science.gov (United States)

    Arslan, Hakan; Yildiz, Ezgi Doganay; Gunduz, Hicran Ates; Sumbullu, Meltem; Bayrakdar, Ibrahim Sevki; Karatas, Ertugrul; Sumbullu, Muhammed Akif

    2017-01-01

    Aim: The aim of this study is to evaluate the root canal transportation, centering ability, and instrumentation times with the ProTaper Gold (Dentsply Tulsa Dental, Tulsa, OK, USA), Reciproc (VDW, Munich, Germany), and ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland) using cone-beam computed tomography (CBCT). Materials and Methods: Thirty mesial root canals of mandibular first molars with curvature angles of 35°–70° and radii of 2–6 mm were included in the study. Root canal instrumentation was performed up to F2 or R25. The instrumentation times were recorded. CBCT scanning was performed both pre- and post-instrumentation. Root canal transportation and the centering ratio were calculated for groups, and the data were analyzed using a one-way ANOVA and least significant difference post hoc tests for the instrumentation time, root canal transportation, and centering ratio at the 95% confidence level (P = 0.05). Results: At 3, 5, and 7 mm levels, there was no significant difference in the root canal transportation and centering ratio among the groups (P > 0.05). There were significant differences between the Reciproc and ProTaper Universal groups in the instrumentation times (P < 0.05). Conclusion: Root canal transportation and the centering ratio with the ProTaper Gold were similar to those obtained with the ProTaper Universal and Reciproc. PMID:29259355

  13. High Efficiency Electron-Laser Interactions in Tapered Helical Undulators

    Science.gov (United States)

    Duris, Joseph Patrick

    Efficient coupling of relativistic electron beams with high power radiation lies at the heart of advanced accelerator and light source research and development. The inverse free electron laser is a stable accelerator capable of harnessing very high intensity laser electric fields to efficiently transfer large powers from lasers to electron beams. In this dissertation, we first present the theoretical framework to describe the interaction, and then apply our improved understanding of the IFEL to the design and numerical study of meter-long, GeV IFELs for compact light sources. The central experimental work of the dissertation is the UCLA BNL helical inverse free electron laser experiment at the Accelerator Test Facility in Brookhaven National Laboratory which used a strongly tapered 54cm long, helical, permanent magnet undulator and a several hundred GW CO2 laser to accelerate electrons from 52 to 106MeV, setting new records for inverse free electron laser energy gain (54MeV) and average accelerating gradient (100MeV/m). The undulator design and fabrication as well as experimental diagnostics are presented. In order to improve the stability and quality of the accelerated electron beam, we redesigned the undulator for a slightly reduced output energy by modifying the magnet gap throughout the undulator, and we used this modified undulator to demonstrated capture of >25% of the injected beam without prebunching. In the study of heavily loaded GeV inverse free electron lasers, we show that a majority of the power may be transferred from a laser to the accelerated electron beam. Reversing the process to decelerate high power electron beams, a mechanism we refer to as tapering enhanced stimulated superradiant amplification, offers a clear path to high power light sources. We present studies of radiation production for a wide range of wavelengths (10mum, 13nm, and 0.3nm) using this method and discuss the design for a deceleration experiment using the same undulator used

  14. Optimization of single-step tapering amplitude and energy detuning for high-gain FELs

    Science.gov (United States)

    Li, He-Ting; Jia, Qi-Ka

    2015-01-01

    We put forward a method to optimize the single-step tapering amplitude of undulator strength and initial energy tuning of electron beam to maximize the saturation power of high gain free-electron lasers (FELs), based on the physics of longitudinal electron beam phase space. Using the FEL simulation code GENESIS, we numerically demonstrate the accuracy of the estimations for parameters corresponding to the linac coherent light source and the Tesla test facility.

  15. High-frequency impedance of small-angle tapers and collimators

    Directory of Open Access Journals (Sweden)

    G. Stupakov

    2010-10-01

    Full Text Available Collimators and transitions in accelerator vacuum chambers often include small-angle tapering to lower the wakefields generated by the beam. While the low-frequency impedance is well described by Yokoya’s formula (for axisymmetric geometry, much less is known about the behavior of the impedance in the high-frequency limit. In this paper we develop an analytical approach to the high-frequency regime for round collimators and tapers. Our analytical results are compared with computer simulations using the code ECHO.

  16. Widely Tunable High-Power Tapered Diode Laser at 1060 nm

    DEFF Research Database (Denmark)

    Jensen, Ole Bjarlin; Sumpf, Bernd; Erbert, Götz

    2011-01-01

    We report a large tuning range from 1018 to 1093 nm from a InGaAs single quantum-well 1060-nm external cavity tapered diode laser. More than 2.5-W output power has been achieved. The tuning range is to our knowledge the widest obtained from a high-power InGaAs single quantum-well tapered laser...... operating around 1060 nm. The light emitted by the laser has a nearly diffraction limited beam quality and a narrow linewidth of less than 6 pm everywhere in the tuning range....

  17. Fabrication of longitudinally arbitrary shaped fiber tapers

    Science.gov (United States)

    Nold, J.; Plötner, M.; Böhme, S.; Sattler, B.; deVries, O.; Schreiber, T.; Eberhardt, R.; Tünnermann, A.

    2018-02-01

    We present our current results on the fabrication of arbitrary shaped fiber tapers on our tapering rig using a CO2-laser as heat source. Single mode excitation of multimode fibers as well as changing the fiber geometry in an LPG-like fashion is presented. It is shown that this setup allows for reproducible fabrication of single-mode excitation tapers to extract the fundamental mode (M2 < 1.1) from a 30 μm core having an NA of 0.09.

  18. Nanofocusing in a tapered graphene plasmonic waveguide

    DEFF Research Database (Denmark)

    Dai, Yunyun; Zhu, Xiaolong; Mortensen, N. Asger

    2015-01-01

    Gated or doped graphene can support plasmons making it a promising plasmonic material in the terahertz regime. Here, we show numerically that in a tapered graphene plasmonic waveguide mid- and far-infrared light can be focused in nanometer scales, far beyond the diffraction limit. The underlying...... physics lies in that when propagating along the direction towards the tip both the group and phase velocities of the plasmons supported by the tapered graphene waveguide are reduced accordingly, eventually leading to nanofocusing at the tip with a huge enhancement of optical fields. The nanofocusing...... of optical fields in tapered graphene plasmonic waveguides could be potentially exploited in the enhancement of light–matter interactions....

  19. Spectral beam combining of diode lasers with high efficiency

    DEFF Research Database (Denmark)

    Müller, André; Vijayakumar, Deepak; Jensen, Ole Bjarlin

    2012-01-01

    Based on spectral beam combining we obtain 16 W of output power, combining two 1063 nm DBR-tapered diode lasers. The spectral separation within the combined beam can be used for subsequent sum-frequency generation.......Based on spectral beam combining we obtain 16 W of output power, combining two 1063 nm DBR-tapered diode lasers. The spectral separation within the combined beam can be used for subsequent sum-frequency generation....

  20. Backstroke start performance: the impact of using the Omega OBL2 backstroke ledge.

    Science.gov (United States)

    Barkwell, Gordon E; Dickey, James P

    2017-10-04

    FINA recently approved the backstroke ledge (Omega OBL2) to improve backstroke start performance in competition, but its performance has not been thoroughly evaluated. The purpose of this study was to compare the mechanics of starts performed with and without the OBL2. Ten high-level backstroke swimmers performed three starts with, and three starts without, the OBL2. A wall-mounted force plate measured the lower limb horizontal impulse, vertical impulse, take-off velocity and take-off angle. Entry distance, time to 10 m and start of hip and knee extension were recorded using video cameras. Starts performed with the OBL2 had a 0.13 s lower time to 10 m, 2.5% less variability in time to 10 m and 0.14 m greater head entry distance. The OBL2 provides a performance advantage by allowing an increased head entry distance rather than larger horizontal impulse on the wall. This may be due to the swimmers assuming different body positions during the start manoeuvre. Additional studies are needed to evaluate factors that contribute to improved performance when using the OBL2. Swimmers should train with the OBL2 and use it in competition to ensure optimal start performance.

  1. 980 nm tapered lasers with photonic crystal structure for low vertical divergence

    Science.gov (United States)

    Ma, Xiaolong; Qu, Hongwei; Zhao, Pengchao; Liu, Yun; Zheng, Wanhua

    2016-10-01

    High power tapered lasers with nearly diffraction-limited beam quality have attracted much attention in numerous applications such as nonlinear frequency conversion, optical pumping of solid-state and fiber lasers, medical treatment and others. However, the large vertical divergence of conventional tapered lasers is a disadvantage, which makes beam shaping difficult and expensive in applications. Diode lasers with photonic crystal structure can achieve a large mode size and a narrow vertical divergence. In this paper, we present tapered lasers with photonic crystal structure emitting at 980 nm. The epitaxial layer is grown using metal organic chemical vapor deposition. The device has a total cavity length of 2 mm, which consists of a 400-um long ridge-waveguide section and a 1600-um long tapered section. The taper angle is 4°. An output power of 3.3 W is achieved with a peak conversion efficiency of 35% in pulsed mode. The threshold current is 240 mA and the slope efficiency is 0.78 W/A. In continuous wave mode, the output power is 2.87 W, which is limited by a suddenly failure resulting from catastrophic optical mirror damage. The far field divergences with full width at half maximum are 12.3° in the vertical direction and 2.9° in the lateral direction at 0.5 A. At high injection level the vertical divergence doesn't exceed 16°. Beam quality factor M2 is measured based on second moment definition in CW mode. High beam quality is demonstrated by M2 value of less than 2 in both vertical and lateral directions.

  2. Efficient generation of 509 nm light by sum-frequency mixing between two tapered diode lasers

    DEFF Research Database (Denmark)

    Tawfieq, Mahmoud; Jensen, Ole Bjarlin; Hansen, Anders Kragh

    2015-01-01

    We demonstrate a concept for visible laser sources based on sum-frequency generation of beam com- bined tapered diode lasers. In this specific case, a 1.7 W sum-frequency generated green laser at 509 nm is obtained, by frequency adding of 6.17 W from a 978 nm tapered diode laser with 8.06 W from...... a 1063 nm tapered diode laser, inside a periodically poled MgO doped lithium niobate crystal. This corresponds to an optical to optical conversion ef fi ciency of 12.1%. As an example of potential applica- tions, the generated nearly diffraction-limited green light is used for pumping a Ti:sapphire laser...

  3. Fiber up-tapering and down-tapering for low-loss coupling between anti-resonant hollow-core fiber and solid-core fiber

    Science.gov (United States)

    Zhang, Naiqian; Wang, Zefeng; Xi, Xiaoming

    2017-10-01

    In this paper, we demonstrate a novel method for the low-loss coupling between solid-core multi-mode fibers (MMFs) and anti-resonant hollow-core fibers (AR-HCFs). The core/cladding diameter of the MMF is 50/125μm and the mode field diameter of the AR-HCFs are 33.3μm and 71.2μm of the ice-cream type AR-HCFs and the non-node type ARHCFs, respectively. In order to match the mode field diameters of these two specific AR-HCFs, the mode field diameter of the MMFs is increased or decreased by up-tapering or down-tapering the MMFs. Then, according to the principle of coupled fiber mode matching, the optimal diameter of tapered fiber for low-loss coupling is calculated. Based on beam propagation method, the calculated coupling losses without tapering process are 0.31dB and 0.89dB, respectively for a MMF-HCF-MMF structure of the ice-cream type AR-HCFs and the non-node type AR-HCFs. These values can be reduced to 0.096dB and 0.047dB when the outer diameters of the MMF are down-tapered to 116μm and up-tapered to 269μm, respectively. What's more, these results can also be verified by existing experiments.

  4. Accelerating and guiding of C6 + by an intense laser irradiating on a foil target with a tapered channel

    Science.gov (United States)

    Lv, Chong; Wan, Feng; Hou, Ya-Juan; Hong, Xue-Ren; Jia, Mo-Ran; Sang, Hai-Bo; Xie, Bai-Song

    2017-08-01

    A novel scheme with a tapered channel attached to an ultra-thin carbon foil is proposed to accelerate and guide carbon ions via breakout afterburner mechanism. Also, the problems involved are investigated by using two-dimensional particle-in-cell simulations. It is demonstrated that the tapered channel can efficiently accelerate and guide carbon ions and result in a much better quality beam with an order of magnitude higher in density and 22% larger in cut-off energy than that without the tapered channel. The enhanced reasons are analyzed in detail, which are mainly attributed to the guidance of the longitudinal electric field and the focus of the transverse electric field, as well as the convergence effect of the tapered channel. All of them are certified to guide greatly carbon ions to move along the longitudinal direction. Besides, during the simulation time, the ion beam with a tapered channel can remain eight times smaller in divergence angle than that without the tapered channel. Such a target may be beneficial to many applications such as ion fast ignition in inertial fusion, high-energy physics, and proton therapy.

  5. WGM-Resonator/Tapered-Waveguide White-Light Sensor Optics

    Science.gov (United States)

    Stekalov, Dmitry; Maleki, Lute; Matsko, Andrey; Savchenkov, Anatoliy; Iltchenko, Vladimir

    2007-01-01

    Theoretical and experimental investigations have demonstrated the feasibility of compact white-light sensor optics consisting of unitary combinations of (1) low-profile whispering-gallery-mode (WGM) resonators and (2) tapered rod optical waveguides. These sensors are highly wavelength-dispersive and are expected to be especially useful in biochemical applications for measuring absorption spectra of liquids. These sensor optics exploit the properties of a special class of non-diffracting light beams that are denoted Bessel beams because their amplitudes are proportional to Bessel functions of the radii from their central axes. High-order Bessel beams can have large values of angular momentum. In a sensor optic of this type, a low-profile WGM resonator that supports modes having large angular momenta is used to generate high-order Bessel beams. As used here, "low-profile" signifies that the WGM resonator is an integral part of the rod optical waveguide but has a radius slightly different from that of the adjacent part(s).

  6. Modeling of Electromagnetic Wave Propagation with Tapered Transmission Line

    Science.gov (United States)

    Lee, Kun-A.; Ko, Kwang-Cheol

    2012-09-01

    Tapered transmission line was used for impedance matching, for high voltage pulse, and atmospheric medium is applied to characteristic equation of tapered transmission line and reflection coefficient so that nonlinear load and circuit modeling of atmospheric medium was simulated by electromagnetic transient program (EMTP). A characteristic of atmospheric medium and Time delay are decided by inductance and capacitance of tapered transmission line. For electromagnetic wave propagation modeling, in this paper, tapered transmission line is implemented. It is difficult to model tapered transmission line directly. Other transmission line that can be expressed by the circuit is used. So object of this paper is efficient modeling of tapered transmission line.

  7. Nanofocusing in a tapered graphene plasmonic waveguide

    International Nuclear Information System (INIS)

    Dai, Yunyun; Zi, Jian; Zhu, Xiaolong; Mortensen, N Asger; Xiao, Sanshui

    2015-01-01

    Gated or doped graphene can support plasmons making it a promising plasmonic material in the terahertz regime. Here, we show numerically that in a tapered graphene plasmonic waveguide mid- and far-infrared light can be focused in nanometer scales, far beyond the diffraction limit. The underlying physics lies in that when propagating along the direction towards the tip both the group and phase velocities of the plasmons supported by the tapered graphene waveguide are reduced accordingly, eventually leading to nanofocusing at the tip with a huge enhancement of optical fields. The nanofocusing of optical fields in tapered graphene plasmonic waveguides could be potentially exploited in the enhancement of light–matter interactions. (paper)

  8. Direct Determination of Absolute Absorption Cross Sections at the L-Edge of Dilute Mn Complexes in Solution Using a Transmission Flatjet.

    Science.gov (United States)

    Kubin, Markus; Guo, Meiyuan; Ekimova, Maria; Baker, Michael L; Kroll, Thomas; Källman, Erik; Kern, Jan; Yachandra, Vittal K; Yano, Junko; Nibbering, Erik T J; Lundberg, Marcus; Wernet, Philippe

    2018-04-10

    The 3d transition metals play a pivotal role in many charge transfer processes in catalysis and biology. X-ray absorption spectroscopy at the L-edge of metal sites probes metal 2p-3d excitations, providing key access to their valence electronic structure, which is crucial for understanding these processes. We report L-edge absorption spectra of Mn II (acac) 2 and Mn III (acac) 3 complexes in solution, utilizing a liquid flatjet for X-ray absorption spectroscopy in transmission mode. With this, we derive absolute absorption cross-sections for the L-edge transitions with peak magnitudes as large as 12 and 9 Mb for Mn II (acac) 2 and Mn III (acac) 3 , respectively. We provide insight into the electronic structure with ab initio restricted active space calculations of these L-edge transitions, reproducing the experimental spectra with excellent agreement in terms of shapes, relative energies, and relative intensities for the two complexes. Crystal field multiplet theory is used to assign spectral features in terms of the electronic structure. Comparison to charge transfer multiplet calculations reveals the importance of charge transfer in the core-excited final states. On the basis of our experimental observations, we extrapolate the feasibility of 3d transition metal L-edge absorption spectroscopy using the liquid flatjet approach in probing highly dilute biological solution samples and possible extensions to table-top soft X-ray sources.

  9. High power tapered lasers with optimized photonic crystal structure for low divergence and high efficiency

    Science.gov (United States)

    Ma, Xiaolong; Qu, Hongwei; Qi, Aiyi; Zhou, Xuyan; Ma, Pijie; Liu, Anjin; Zheng, Wanhua

    2018-04-01

    High power tapered lasers are designed and fabricated. A one-dimensional photonic crystal structure in the vertical direction is adopted to narrow the far field divergence. The thickness of the defect layer and the photonic crystal layers are optimized by analyzing the optical field theoretically. For tapered lasers, the continuous-wave power is 7.3 W and the pulsed power is 17 W. A maximum wall-plug efficiency of 46% under continuous-wave operation and 49.3% in pulsed mode are obtained. The beam divergences are around 11° and 6° for the vertical and lateral directions, respectively. High beam qualities are also obtained with a vertical M2 value of 1.78 and a lateral M2 value of 1.62. As the current increases, the lateral M2 value increases gradually while the vertical M2 value remains around 2.

  10. Tapered photonic crystal fibers for blue-enhanced supercontinuum generation

    DEFF Research Database (Denmark)

    Møller, Uffe; Sørensen, Simon Toft; Larsen, Casper

    2012-01-01

    Tapering of photonic crystal fibers is an effective way of shifting the blue edge of a supercontinuum spectrum down in the deep-blue. We discuss the optimum taper profile for enhancing the power in the blue edge....

  11. 77 FR 50716 - Tapered Roller Bearings From China

    Science.gov (United States)

    2012-08-22

    ... COMMISSION Tapered Roller Bearings From China Determination On the basis of the record \\1\\ developed in the... antidumping duty order on tapered roller bearings from China would be likely to lead to continuation or... Publication 4343 (August 2012), entitled Tapered Roller Bearings from China: Investigation No. 731-TA-344...

  12. Pump and Signal Taper for Airclad Fibers

    National Research Council Canada - National Science Library

    Kristiansen, Rene E; Nielsen, Martin D

    2006-01-01

    This report results from a contract tasking Crystal Fibre A/S as follows: Crystal Fibre A/S will develop a taper/coupler solution to interface between a new polarization maintaining/polarizing amplifier fiber (DC-200-35-Yb-PM...

  13. Compatible taper equation for loblolly pine

    Science.gov (United States)

    J. P. McClure; R. L. Czaplewski

    1986-01-01

    Cao's compatible, segmented polynomial taper equation (Q. V. Cao, H. E. Burkhart, and T. A. Max. For. Sci. 26: 71-80. 1980) is fitted to a large loblolly pine data set from the southeastern United States. Equations are presented that predict diameter at a given height, height to a given top diameter, and volume below a given position on the main stem. All...

  14. Coherent combining of high brightness tapered lasers in master oscillator power amplifier configuration

    Science.gov (United States)

    Albrodt, P.; Hanna, M.; Moron, F.; Decker, J.; Winterfeldt, M.; Blume, G.; Erbert, G.; Crump, P.; Georges, P.; Lucas-Leclin, G.

    2018-02-01

    Improved diode laser beam combining techniques are in strong demand for applications in material processing. Coherent beam combining (CBC) is the only combining approach that has the potential to maintain or even improve all laser properties, and thus has high potential for future systems. As part of our ongoing studies into CBC of diode lasers, we present recent progress in the coherent superposition of high-power single-pass tapered laser amplifiers. The amplifiers are seeded by a DFB laser at λ = 976 nm, where the seed is injected into a laterally single-mode ridge-waveguide input section. The phase pistons on each beam are actively controlled by varying the current in the ridge section of each amplifier, using a sequential hill-climbing algorithm, resulting in a combined beam with power fluctuations of below 1%. The currents into the tapered sections of the amplifiers are separately controlled, and remain constant. In contrast to our previous studies, we favour a limited number of individual high-power amplifiers, in order to preserve a high extracted power per emitter in a simple, low-loss coupling arrangement. Specifically, a multi-arm interferometer architecture with only three devices is used, constructed using 6 mm-long tapered amplifiers, mounted junction up on C-mounts, to allow separate contact to single mode and amplifier sections. A maximum coherently combined power of 12.9 W is demonstrated in a nearly diffraction-limited beam, corresponding to a 65% combining efficiency, with power mainly limited by the intrinsic beam quality of the amplifiers. Further increased combined power is currently sought.

  15. Performance of an elliptically tapered neutron guide

    International Nuclear Information System (INIS)

    Muehlbauer, Sebastian; Stadlbauer, Martin; Boeni, Peter; Schanzer, Christan; Stahn, Jochen; Filges, Uwe

    2006-01-01

    Supermirror coated neutron guides are used at all modern neutron sources for transporting neutrons over large distances. In order to reduce the transmission losses due to multiple internal reflection of neutrons, ballistic neutron guides with linear tapering have been proposed and realized. However, these systems suffer from an inhomogeneous illumination of the sample. Moreover, the flux decreases significantly with increasing distance from the exit of the neutron guide. We propose using elliptically tapered guides that provide a more homogeneous phase space at the sample position as well as a focusing at the sample. Moreover, the design of the guide system is simplified because ellipses are simply defined by their long and short axes. In order to prove the concept we have manufactured a doubly focusing guide and investigated its properties with neutrons. The experiments show that the predicted gains using the program package McStas are realized. We discuss several applications of elliptic guides in various fields of neutron physics

  16. L-Edge X-ray Absorption Spectroscopy of Dilute Systems Relevant to Metalloproteins Using an X-ray Free-Electron Laser

    NARCIS (Netherlands)

    Mitzner, Rolf; Rehanek, Jens; Kern, Jan; Gul, Sheraz; Hattne, Johan; Taguchi, Taketo; Alonso-Mori, Roberto; Tran, Rosalie; Weniger, Christian; Schroeder, Henning; Quevedo, Wilson; Laksmono, Hartawan; Sierra, Raymond G.; Han, Guangye; Lassalle-Kaiser, Benedikt; Koroidov, Sergey; Kubicek, Katharina; Schreck, Simon; Kunnus, Kristjan; Brzhezinskaya, Maria; Firsov, Alexander; Minitti, Michael P.; Turner, Joshua J.; Moeller, Stefan; Sauter, Nicholas K.; Bogan, Michael J.; Nordlund, Dennis; Schlotter, William F.; Messinger, Johannes; Borovik, Andrew; Techert, Simone; de Groot, Frank M. F.|info:eu-repo/dai/nl/08747610X; Foehlisch, Alexander; Erko, Alexei; Bergmann, Uwe; Yachandra, Vittal K.; Wernet, Philippe; Yano, Junko

    2013-01-01

    L-edge spectroscopy of 3d transition metals provides important electronic structure information and has been used in many fields. However, the use of this method for studying dilute aqueous systems, such as metalloenzymes, has not been prevalent because of severe radiation damage and the lack of

  17. An undulator with non-adiabatic tapering for the IFEL project

    CERN Document Server

    Varfolomeev, A A; Yarovoi, T V; Musumeci, P; Pellegrini, C; Rosenzweig, J

    2002-01-01

    We describe the design of a planar undulator with unusually strong tapering, for the inverse FEL experiment to be carried out in Neptune Lab. (Nucl. Instr. and Meth. A 410 (1998) 437) at UCLA. A powerful TW CO sub 2 laser will be used to accelerate electrons up to 50-60 MeV in 50 cm long undulator. A strong undulator tapering is needed because of the short Rayleigh length of the laser beam. Both the magnetic field and the undulator period are tapered to provide synchronicity of the laser beam interaction with a captured electron bunch along the whole undulator length. The most critical part of the undulator is the region near the laser focus. The main characteristics of the IFEL, such as the percentage of trapped electrons, energy of accelerated electrons and sensitivity to the laser focus transverse position, are given. The general principles of the design of this undulator construction can also be useful for high efficiency FEL amplifiers of intense laser modes.

  18. Opioid tapering in hematopoietic progenitor cell transplant recipients.

    Science.gov (United States)

    Pederson, C; Parran, L

    2000-10-01

    To describe current opioid-tapering practice, patient pain levels and withdrawal symptoms, and nurse documentation during opioid tapers. Descriptive, exploratory, prospective, quantitative, and qualitative. A 32-bed blood and marrow transplant unit in a large, tertiary U.S. care center. 45 blood and marrow transplant recipients between the ages of 7-64. Types of transplant were autologous, allogeneic, and unrelated donor marrow; peripheral blood stem cell; and umbilical cord blood. In daily interviews, patients reported pain levels and withdrawal symptoms during opioid tapers. Demographic, medication, and nurse documentation data were obtained from patient hospital records. Taper length, daily opioid dosage, pain, withdrawal symptoms, and nurse documentation. Length of taper ranged from 1-17 days (X = 6.53, SD = 4.26). Analysis of variance indicated no difference by disease or transplant type in length of taper, cumulative opioids given pretaper or during taper, or number of self-reports of withdrawal symptoms. Daily changes in nurse-administered opioid dosage during tapers ranged from a decrease of 67% to an increase of 14%. Children received significantly more opioids/kg during taper than adults. Means of adults' and children's self-reports of pain were low. The means of patient-reported withdrawal symptoms were highest on taper days two through six. Nurse documentation was sparse. Daily taper rates vary widely, pain is well managed, and most patients experience several withdrawal symptoms. Use of an opioid-taper guideline may promote consistency of tapering while not increasing levels of pain or withdrawal symptoms.

  19. Tapering Practices of Croatian Open-Class Powerlifting Champions.

    Science.gov (United States)

    Grgic, Jozo; Mikulic, Pavle

    2017-09-01

    Grgic, J and Mikulic, P. Tapering practices of Croatian open-class powerlifting champions. J Strength Cond Res 31(9): 2371-2378, 2017-The aim of this study was to explore tapering practices among 10 Croatian open-class powerlifting champions (mean ± SD: age 29.2 ± 3.2 years; Wilks coefficient 355.1 ± 54.8). The athletes were interviewed about their tapering practices using a semi-structured interview after which the audio content was transcribed. The athletes reported decreasing training volume during the taper by 50.5 ± 11.7% using a step type or an exponential type of taper with a fast decay. Training intensity was maintained or increased during the taper, and it reached its highest values 8 ± 3 days before the competition. Training frequency was reduced or maintained during the taper. The final week included a reduction in training frequency by 47.9 ± 17.5% with the last training session performed 3 ± 1 days before the competition. The participants typically stated that the main reasons for conducting the taper were maintaining strength and reducing the amount of fatigue. They also stated that (a) the taper was structured identically for the squat, bench press, and the deadlift; (b) the training during the taper was highly specific, the assistance exercises were removed, and the same equipment was used as during competition; (c) the source of information for tapering was their coach, and training fluctuated based on the coach's feedback; and (d) nutrition, foam rolling, static stretching, and massage were all given extra attention during the taper. These results may aid athletes and coaches in strength sports in terms of the optimization of tapering variables.

  20. On the dynamics of tapered vibro-impacting cantilever with tip mass

    Energy Technology Data Exchange (ETDEWEB)

    Gandhi, P. S.; Vyas, Vishal [Suman Mashruwala Advanced Microengineering Laboratory, Dept. of Mechanical Engineering, Indian Institute of Technology - Bombay, Mumai (India)

    2017-01-15

    This paper explores nonlinear dynamic behavior of vibro-impacting tapered cantilever with tip mass with regard to frequency response analysis. A typical frequency response curve of vibro-impacting beams displays well-known resonance frequency shift along with a hysteric jump and drop phenomena. We did a comprehensive parametric analysis capturing the effects of taper, tip-mass, stop location, and gap on the non-smooth frequency response. Analysis is presented in a non-dimensional form useful for other similar cases. Simulation results are further validated with corresponding experimental results for a few cases. Illustrative comparison of simulation results for varying parameters brings out several interesting aspects of variation in the nonlinear behavior.

  1. Nonlinear Optics with Tapered Fibers and Magneto-Optically Trapped Rubidium

    Science.gov (United States)

    Little, Bethany; Mullarkey, Chris; Howell, John; Vamivakas, Nick; Lin, Qiang

    2016-05-01

    Tapered optical fibers of sub-wavelength diameter present a promising means of integrating the light-atom interaction into larger scale devices. We present work on a tapered fiber system loaded by a magneto optical trap of Rubidium atoms, in which a combination of red and blue detuned beams create a one-dimensional lattice trap along the fiber. The same fiber is used for interacting with the atoms in the trap via the evanescent fields of light propagating along the fiber. Light storage has been demonstrated in a similar system with Cesium, and we believe that much nonlinear optics remains to be explored in this regime. We also plan to see how these nonlinear effects can be enhanced with the addition of a micro-resonator such as the ones in.

  2. Phase Centers of Subapertures in a Tapered Aperture Array.

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin W. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Bickel, Douglas L. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-11-01

    Antenna apertures that are tapered for sidelobe control can also be parsed into subapertures for Direction of Arrival (DOA) measurements. However, the aperture tapering complicates phase center location for the subapertures, knowledge of which is critical for proper DOA calculation. In addition, tapering affects subaperture gains, making gain dependent on subaperture position. Techniques are presented to calculate subaperture phase center locations, and algorithms are given for equalizing subapertures’ gains. Sidelobe characteristics and mitigation are also discussed.

  3. Welding-fume-induced transmission loss in tapered optical fibers

    Science.gov (United States)

    Yi, Ji-Haeng

    2015-09-01

    This paper presents a method for sensing welding fumes in real time. This method is based on the results of nanoparticle-induced optical-fiber loss experiments that show that the losses are determined by the nanoparticle density and the taper waist. The tapered fiber is obtained by applying heat radiated from hot quartz, and monitoring is done in real time. First, the durability of the tapered fiber during the welding process is proven. Then, the loss is categorized by using the sizes of welding fume particles. The sensitivity to welding fumes increases with increasing size of the particles; consequently, the dimension of the taper waist decreases.

  4. Chemical tapering of polymer optical fiber

    Science.gov (United States)

    Rashid, Affa Rozana Abdul; Afiqah Nasution, Amna; Hanim Suranin, Aisyah; Athirah Taib, Nur; Maisarah Mukhtar, Wan; Dasuki, Karsono Ahmad; Annuar Ehsan, Abang

    2017-11-01

    Polymer optical fibers (POFs) have significant advantages over numerous sensing applications. The key element in developing sensor is by removing the cladding of the fiber. The use of organic solvent is one of the methods to create tapered POF in order to expose the core region. In this study, the etching chemicals involved is acetone, methyl isobutyl ketone (MIBK), and acetone-methanol mixture. The POF is immersed in 100%, 80%, and 50% of acetone and MIBK dilution. In addition, the mixture of acetone and methanol is also used for POF etching by the ratio 2:1 of the volume. Acetone has shown to be the most reactive solvent towards POF due to its fastest etching rate compared to MIBK and acetone-methanol mixture. The POF is immersed and lifted from the solution for a specific time, depending on the power loss properties for the purpose of producing unclad POF. In comparison to silica fiber optic, the advantages of POF in terms of its simple technique and easy handling enable it to produce unclad POF without damaging the core region. The surface roughness of the POF is investigated under the microscope after being immersed into different solvent. This method of chemical tapering of POF can be used as the fundamental technique for sensor development. Next, the unclad fiber is immersed into ethanol solutions in order to determine the reaction of unclad POF towards its surrounding. The findings show that this particular sensor is sensitive towards concentration changes ranging between 10 wt% to 50 wt%.

  5. Tapering-induced enhancement of light extraction efficiency of nanowire deep ultraviolet LED by theoretical simulations

    KAUST Repository

    Lin, Ronghui

    2018-04-21

    A nanowire (NW) structure provides an alternative scheme for deep ultraviolet light emitting diodes (DUV-LEDs) that promises high material quality and better light extraction efficiency (LEE). In this report, we investigate the influence of the tapering angle of closely packed AlGaN NWs, which is found to exist naturally in molecular beam epitaxy (MBE) grown NW structures, on the LEE of NW DUV-LEDs. It is observed that, by having a small tapering angle, the vertical extraction is greatly enhanced for both transverse magnetic (TM) and transverse electric (TE) polarizations. Most notably, the vertical extraction of TM emission increased from 4.8% to 24.3%, which makes the LEE reasonably large to achieve high-performance DUV-LEDs. This is because the breaking of symmetry in the vertical direction changes the propagation of the light significantly to allow more coupling into radiation modes. Finally, we introduce errors to the NW positions to show the advantages of the tapered NW structures can be projected to random closely packed NW arrays. The results obtained in this paper can provide guidelines for designing efficient NW DUV-LEDs.

  6. Development of a tapered cell drift chamber. Pt. 2

    International Nuclear Information System (INIS)

    Blissett, J.A.; Hasell, D.K.; Parham, A.G.; Payne, B.T.; Saxon, D.H.

    1986-01-01

    Several designs for drift cells have been constructed and tested in an electron beam at DESY. The designs tested consisted of pairs of adjacent tapered cells, of eight sense wires each, to simulate a portion of a layer of drift cells in a central tracking detector. For operation in a magnetic field three different tilts for the plane of the sense wires (0 0 , 20 0 and 45 0 ) were used. Tests were made to study the operation and resolution of the drift cells under a variety of conditions. Ar:C 2 H 6 (50:50) and Ar:CO 2 :CH 4 (90:9:1) gas mixtures were used at absolute pressures of 1 to 4 bar for the former and at 1 bar for the latter. Measurements were made at different electric drift fields in conjunction with magnetic fields varying from 0 to 1.82 T. Aspects of the construction, electronics and operation are discussed and results regarding the resolution as a function of drift distance and operating conditions are presented with some model calculation. (orig.)

  7. Volume and Implicit Taper Functions For Cupressus Lusitanica and ...

    African Journals Online (AJOL)

    Implicit taper functions derived from the exponential form merchantable volume models were found superior to taper functions obtained from the non exponential merchantable volume models. In general, these models are essential management tools for the plantation of the species and in particular provide stock volume ...

  8. Catalog of Window Taper Functions for Sidelobe Control

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin W.

    2017-04-01

    Window taper functions of finite apertures are well-known to control undesirable sidelobes, albeit with performance trades. A plethora of various taper functions have been developed over the years to achieve various optimizations. We herein catalog a number of window functions, and com pare principal characteristics.

  9. A taper function for Pseudotsuga menziesii plantations in Spain ...

    African Journals Online (AJOL)

    Five stem taper models belonging to three different taper function categories were fitted to data corresponding to 282 Pseudotsuga menziesii trees. The trees were selected in the area surrounding 61 research plots installed in Galicia, Asturias and the Basque Country, northern Spain. The models were simultaneously fitted ...

  10. Optimum PCF tapers for blue-enhanced supercontinuum sources

    DEFF Research Database (Denmark)

    Møller, Uffe Visbech; Sørensen, Simon Toft; Larsen, Casper

    2012-01-01

    Tapering of photonic crystal fibers has proven to be an effective way of blueshifting the dispersive wavelength edge of a supercontinuum spectrum down in the deep-blue. In this article we will review the state-of-the-art in fiber tapers, and discuss the underlying mechanisms of supercontinuum gen...

  11. High power supercontinuum generation in tapered photonic crystal fibers

    DEFF Research Database (Denmark)

    Møller, Uffe; Sørensen, Simon Toft; Larsen, Casper

    2012-01-01

    Tapering of photonic crystal fibers has proven to be an effective way of blueshifting the dispersive wavelength edge of a supercontinuum spectrum down in the deep-blue. In this contribution we will discuss the underlying mechanisms of supercontinuum generation in tapers. We show, by introducing t...

  12. Wizard CD Plus and ProTaper Universal: analysis of apical transportation using new software.

    Science.gov (United States)

    Giannastasio, Daiana; Rosa, Ricardo Abreu da; Peres, Bernardo Urbanetto; Barreto, Mirela Sangoi; Dotto, Gustavo Nogara; Kuga, Milton Carlos; Pereira, Jefferson Ricardo; Só, Marcus Vinícius Reis

    2013-01-01

    This study has two aims: 1) to evaluate the apical transportation of the Wizard CD Plus and ProTaper Universal after preparation of simulated root canals; 2) to compare, with Adobe Photoshop, the ability of a new software (Regeemy) in superposing and subtracting images. Twenty five simulated root canals in acrylic-resin blocks (with 20º curvature) underwent cone beam computed tomography before and after preparation with the rotary systems (70 kVp, 4 mA, 10 s and with the 8×8 cm FoV selection). Canals were prepared up to F2 (ProTaper) and 24.04 (Wizard CD Plus) instruments and the working length was established to 15 mm. The tomographic images were imported into iCAT Vision software and CorelDraw for standardization. The superposition of pre- and post-instrumentation images from both systems was performed using Regeemy and Adobe Photoshop. The apical transportation was measured in millimetres using Image J. Five acrylic resin blocks were used to validate the superposition achieved by the software. Student's t-test for independent samples was used to evaluate the apical transportation achieved by the rotary systems using each software individually. Student's t-test for paired samples was used to compare the ability of each software in superposing and subtracting images from one rotary system per time. The values obtained with Regeemy and Adobe Photoshop were similar to rotary systems (P>0.05). ProTaper Universal and Wizard CD Plus promoted similar apical transportation regardless of the software used for image's superposition and subtraction (P>0.05). Wizard CD Plus and ProTaper Universal promoted little apical transportation. Regeemy consists in a feasible software to superpose and subtract images and appears to be an alternative to Adobe Photoshop.

  13. Wizard CD Plus and ProTaper Universal: analysis of apical transportation using new software

    Directory of Open Access Journals (Sweden)

    Daiana Giannastasio

    2013-09-01

    Full Text Available OBJECTIVE: This study has two aims: 1 to evaluate the apical transportation of the Wizard CD Plus and ProTaper Universal after preparation of simulated root canals; 2 to compare, with Adobe Photoshop, the ability of a new software (Regeemy in superposing and subtracting images. MATERIAL AND METHODS: Twenty five simulated root canals in acrylic-resin blocks (with 20º curvature underwent cone beam computed tomography before and after preparation with the rotary systems (70 kVp, 4 mA, 10 s and with the 8×8 cm FoV selection. Canals were prepared up to F2 (ProTaper and 24.04 (Wizard CD Plus instruments and the working length was established to 15 mm. The tomographic images were imported into iCAT Vision software and CorelDraw for standardization. The superposition of pre- and post-instrumentation images from both systems was performed using Regeemy and Adobe Photoshop. The apical transportation was measured in millimetres using Image J. Five acrylic resin blocks were used to validate the superposition achieved by the software. Student's t-test for independent samples was used to evaluate the apical transportation achieved by the rotary systems using each software individually. Student's t-test for paired samples was used to compare the ability of each software in superposing and subtracting images from one rotary system per time. RESULTS: The values obtained with Regeemy and Adobe Photoshop were similar to rotary systems (P>0.05. ProTaper Universal and Wizard CD Plus promoted similar apical transportation regardless of the software used for image's superposition and subtraction (P>0.05. CONCLUSION: Wizard CD Plus and ProTaper Universal promoted little apical transportation. Regeemy consists in a feasible software to superpose and subtract images and appears to be an alternative to Adobe Photoshop.

  14. In situ investigation of wet chemical processes for chalcopyrite solar cells by L-edge XAS under ambient conditions

    Energy Technology Data Exchange (ETDEWEB)

    Greil, Stefanie M. [Helmholtz-Zentrum Berlin fuer Materialien und Energie, Albert-Einstein-Strasse 15, 12489 Berlin (Germany); Lauermann, Iver, E-mail: Iver.lauermann@helmholtz-berlin.d [Helmholtz-Zentrum Berlin fuer Materialien und Energie, Albert-Einstein-Strasse 15, 12489 Berlin (Germany); Ennaoui, Ahmed; Kropp, Timo; Lange, Kathrin M.; Weber, Matthieu [Helmholtz-Zentrum Berlin fuer Materialien und Energie, Albert-Einstein-Strasse 15, 12489 Berlin (Germany); Aziz, Emad F., E-mail: Emad.Aziz@helmholtz-berlin.d [Helmholtz-Zentrum Berlin fuer Materialien und Energie, Albert-Einstein-Strasse 15, 12489 Berlin (Germany)

    2010-02-15

    Two instrumental setups for in situ soft X-ray absorption spectroscopy in liquid systems are demonstrated in this work. One for investigating chemical reactions in solutions and a new one for the solid component of a liquid / (as in both / absorber) solid interface. We used these setups for investigating two production processes for chalcopyrite solar cells under ambient conditions, probing the L-edge of Zn and Cu. The first one is a flow cell with a silicon nitride membrane to study the chemical bath deposition process for Cd-free buffer layers. Examining the electronic structure of involved Zn complexes allows to determine the exact reaction mechanism taking place during this process. The second setup is a rotating disk for investigating the bath/absorber interface upon the etching process of superficial binary copper compounds of the absorber as a function of time. The time resolution of the chemical reaction demonstrated in this study ranges from the second to minute time scale.

  15. In situ investigation of wet chemical processes for chalcopyrite solar cells by L-edge XAS under ambient conditions

    International Nuclear Information System (INIS)

    Greil, Stefanie M.; Lauermann, Iver; Ennaoui, Ahmed; Kropp, Timo; Lange, Kathrin M.; Weber, Matthieu; Aziz, Emad F.

    2010-01-01

    Two instrumental setups for in situ soft X-ray absorption spectroscopy in liquid systems are demonstrated in this work. One for investigating chemical reactions in solutions and a new one for the solid component of a liquid / (as in both / absorber) solid interface. We used these setups for investigating two production processes for chalcopyrite solar cells under ambient conditions, probing the L-edge of Zn and Cu. The first one is a flow cell with a silicon nitride membrane to study the chemical bath deposition process for Cd-free buffer layers. Examining the electronic structure of involved Zn complexes allows to determine the exact reaction mechanism taking place during this process. The second setup is a rotating disk for investigating the bath/absorber interface upon the etching process of superficial binary copper compounds of the absorber as a function of time. The time resolution of the chemical reaction demonstrated in this study ranges from the second to minute time scale.

  16. In situ investigation of wet chemical processes for chalcopyrite solar cells by L-edge XAS under ambient conditions

    Science.gov (United States)

    Greil, Stefanie M.; Lauermann, Iver; Ennaoui, Ahmed; Kropp, Timo; Lange, Kathrin M.; Weber, Matthieu; Aziz, Emad F.

    2010-02-01

    Two instrumental setups for in situ soft X-ray absorption spectroscopy in liquid systems are demonstrated in this work. One for investigating chemical reactions in solutions and a new one for the solid component of a liquid / (as in both / absorber) solid interface. We used these setups for investigating two production processes for chalcopyrite solar cells under ambient conditions, probing the L-edge of Zn and Cu. The first one is a flow cell with a silicon nitride membrane to study the chemical bath deposition process for Cd-free buffer layers. Examining the electronic structure of involved Zn complexes allows to determine the exact reaction mechanism taking place during this process. The second setup is a rotating disk for investigating the bath/absorber interface upon the etching process of superficial binary copper compounds of the absorber as a function of time. The time resolution of the chemical reaction demonstrated in this study ranges from the second to minute time scale.

  17. Chemical tapering of polymer optical fiber

    Directory of Open Access Journals (Sweden)

    Abdul Rashid Affa Rozana

    2017-01-01

    Full Text Available Polymer optical fibers (POFs have significant advantages over numerous sensing applications. The key element in developing sensor is by removing the cladding of the fiber. The use of organic solvent is one of the methods to create tapered POF in order to expose the core region. In this study, the etching chemicals involved is acetone, methyl isobutyl ketone (MIBK, and acetone-methanol mixture. The POF is immersed in 100%, 80%, and 50% of acetone and MIBK dilution. In addition, the mixture of acetone and methanol is also used for POF etching by the ratio 2:1 of the volume. Acetone has shown to be the most reactive solvent towards POF due to its fastest etching rate compared to MIBK and acetone-methanol mixture. The POF is immersed and lifted from the solution for a specific time, depending on the power loss properties for the purpose of producing unclad POF. In comparison to silica fiber optic, the advantages of POF in terms of its simple technique and easy handling enable it to produce unclad POF without damaging the core region. The surface roughness of the POF is investigated under the microscope after being immersed into different solvent. This method of chemical tapering of POF can be used as the fundamental technique for sensor development. Next, the unclad fiber is immersed into ethanol solutions in order to determine the reaction of unclad POF towards its surrounding. The findings show that this particular sensor is sensitive towards concentration changes ranging between 10 wt% to 50 wt%.

  18. Diagnosis Taper Corrosion: When Is It the Taper and When Is It Something Else?

    Science.gov (United States)

    Della Valle, Craig J; Calkins, Tyler E; Jacobs, Joshua J

    2018-03-01

    There has been an increasing use of modularity at the head-neck junction in total hip arthroplasty to more closely mimic the native anatomy, allowing for optimal leg length and stability. Corrosion at this junction in metal-on-polyethylene bearings can lead to an adverse local tissue reaction (ALTR). This increasingly prevalent condition should be considered in the differential diagnosis of hip pain and difficulty ambulating. A recent symposium by the American Academy of Hip and Knee Surgeons described the diagnosis, etiology, management, and prevention of taper corrosion. This article describes the history, physical, plain and advanced imaging findings, laboratory tests, and other diagnoses that should be taken into consideration when diagnosing taper corrosion. The presence of ALTR due to taper corrosion can mimic other diagnoses such as periprosthetic joint infection, instability, or aseptic loosening. Serum metal levels have been found to be the most effective screening tool for identifying corrosion, but other common causes of hip pain and difficulty ambulating should always be ruled out with the use of radiographs and common laboratory techniques before diagnosing ALTR due to corrosion. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Numerical study of hub taper angle on podded propeller performance

    International Nuclear Information System (INIS)

    Islam, M.F.; Veitch, B.; Bose, N.; Liu, P.

    2005-01-01

    Presently, the majority of podded propulsion systems are of the pulling type, because this type provides better hydrodynamic efficiency than the pushing type. There are several possible explanations for the better overall performance of a puller type podded propulsor. One is related to the difference in hub shape. Puller and pusher propellers have opposite hub taper angles, hence different hub and blade root shape. These differences cause changes in the flow condition and possibly influence the overall performance. The current study focuses on the variation in performance of pusher and puller propellers with the same blade sections, but different hub taper angles. A hyperboloidal low order source doublet steady/unsteady time domain panel method code was modified and used to evaluate effects of hub taper angle on the open water propulsive performance of some fixed pitch screw propellers used in podded propulsion systems. The modified code was first validated against measurements of two model propellers in terms of average propulsive performance and good agreement was found. Major findings include significant effects of hub taper angle on propulsive performance of tapered hub propellers and noticeable effects of hub taper angle on sectional pressure distributions of tapered hub propeller blades. (author)

  20. Nanostructures for very broadband or multi-frequency transition from wave beams to a subwavelength light distributions

    OpenAIRE

    Luukkonen, O.; Pniewski, J.; Simovski, C.

    2011-01-01

    In this paper we suggest and theoretically study a tapered plasmonic nanostructure which connects the incident wave beam with a subwavelength spatial region where the field is locally enhanced in a broad frequency range or for different operation frequencies. This spatial region has a frequency stable location near the contour of the tapered structure. This results from a special waveguide mode which can also exist in the tapered structure. We foresee many possible applications for our struct...

  1. Efficient generation of 3.9 W of diffraction-limited green light with spectrally combined tapered diode lasers

    DEFF Research Database (Denmark)

    Müller, André; Jensen, Ole Bjarlin; Andersen, Peter E.

    We propose an efficient concept increasing the power of diode laser systems in the visible spectral range. In comparison with second harmonic generation of single emitters, spectral beam combining with subsequent sum-frequency generation enhances the available power significantly. Combining two...... 1060 nm tapered diode lasers, we achieve a 2.5-3.2 fold increase of green light with a maximum power of 3.9 Watts in a diffraction-limited beam. At this level, diode lasers have a high application potential, for example, within the biomedical field. In order to enhance the power even further, our...

  2. Efficient concept generating 3.9 W of diffraction-limited green light with spectrally combined tapered diode lasers

    DEFF Research Database (Denmark)

    Müller, André; Jensen, Ole Bjarlin; Hasler, Karl-Heinz

    2013-01-01

    We propose an efficient concept increasing the power of diode laser systems in the visible spectral range. In comparison with second harmonic generation of single emitters, we show that spectral beam combining with subsequent sumfrequency generation enhances the available power significantly....... Combining two 1060 nm distributed Bragg reflector tapered diode lasers (M 24σ ≤ 5.2), we achieve a 2.5-3.2 fold increase of green light with a maximum power of 3.9 Watts in a diffraction-limited beam (M 24σ ≤ 1.3). Without any further stabilization the obtained power stability is within ± 2.6 %. The electro...

  3. Tapered diode laser pumped 946 nm Nd:YAG laser

    DEFF Research Database (Denmark)

    Cheng, Haynes Pak Hay; Jensen, Ole Bjarlin; Petersen, Paul Michael

    2009-01-01

    We successfully implemented a 946 nm Nd:YAG laser based on a 808 nm tapered diode pump laser. The tapered diode is developed at the Ferdinand-Braun-Institute fur Hochstfrequenztechnik in Germany. Figure 2 shows the experimental setup and results of each pump source coupled into a 1.5 mm crystal...... laser, we show that tapered diode laser pumping potentially increase the power of 946 nm lasers by a factor of two and reduce the threshold by a factor of three....

  4. [Features and advances of Morse taper connection in oral implant].

    Science.gov (United States)

    Tang, C L; Zhao, S K; Huang, C

    2017-01-09

    Dental implants have been widely accepted as a predictable and reliable tool for dental reconstruction with the development of the economy. The design of implant-abutment connections has influence on mechanical properties and biological characteristics of implants. There are two types of implant-abutment connections, the external and the internal connections. Morse taper connection is one of the internal connections and its conical shape creates significant friction via the high propensity of parallelism between the two structures within the joint space. Several studies showed that Morse taper connection performed well in terms of survival rate, stability, bacterial seal and marginal bone loss. Recently, clinical studies indicate implants combining Morse taper connection with platform switching are helpful in reducing marginal bone absorption. This review aims at analyzing the features and advantages of Morse taper connection.

  5. Adiabatic tapered optical fiber fabrication in two step etching

    Science.gov (United States)

    Chenari, Z.; Latifi, H.; Ghamari, S.; Hashemi, R. S.; Doroodmand, F.

    2016-01-01

    A two-step etching method using HF acid and Buffered HF is proposed to fabricate adiabatic biconical optical fiber tapers. Due to the fact that the etching rate in second step is almost 3 times slower than the previous droplet etching method, terminating the fabrication process is controllable enough to achieve a desirable fiber diameter. By monitoring transmitted spectrum, final diameter and adiabaticity of tapers are deduced. Tapers with losses about 0.3 dB in air and 4.2 dB in water are produced. The biconical fiber taper fabricated using this method is used to excite whispering gallery modes (WGMs) on a microsphere surface in an aquatic environment. So that they are suitable to be used in applications like WGM biosensors.

  6. Combination nicotine replacement therapy: strategies for initiation and tapering.

    Science.gov (United States)

    Hsia, Stephanie L; Myers, Mark G; Chen, Timothy C

    2017-04-01

    Several studies and meta-analyses have demonstrated the efficacy of combination nicotine replacement therapy (NRT) for patients who wish to quit smoking. However, there is limited guidance with respect to initiation and tapering of combination NRT. We attempt to review the evidence and rationale behind combination NRT, present the dosing used in combination NRT studies, and propose a step-down approach for tapering of combination NRT with integration of behavioral strategies. Copyright © 2017. Published by Elsevier Inc.

  7. Asymmetrically and symmetrically coated tapered optical fiber for sensing applications

    Science.gov (United States)

    Del Villar, Ignacio; Socorro, Abian B.; Corres, Jesus M.; Arregui, Francisco J.; Matias, Ignacio R.

    2015-09-01

    The deposition of a non-metallic thin-film in a symmetrically coated tapered optical fiber leads to the generation of resonances due to guidance of a mode in the thin-film. At certain conditions, the resonances overlap each other, which can be avoided with an asymmetric coated tapered optical fiber, which permits to obtain resonances for TM and TE polarization separately. Numerical results showing the sensitivity to coating thickness and surrounding medium refractive index are also presented for both polarizations.

  8. Gaussian Filtering with Tapered Liquid Crystal Photonic Bandgap Fibers

    DEFF Research Database (Denmark)

    Scolari, Lara; Alkeskjold, Thomas Tanggaard; Bjarklev, Anders Overgaard

    2006-01-01

    We present a device based on a tapered Liquid Crystal Photonic Bandgap Fiber that allows active all-in-fiber filtering. The resulting Photonic Bandgap Fiber device provides a Gaussian filter covering the wavelength range 1200-1600 nm......We present a device based on a tapered Liquid Crystal Photonic Bandgap Fiber that allows active all-in-fiber filtering. The resulting Photonic Bandgap Fiber device provides a Gaussian filter covering the wavelength range 1200-1600 nm...

  9. Identification of the Procedural Accidents During Root Canal Preparation Using Digital Intraoral Radiography and Cone Beam Computed Tomography

    Directory of Open Access Journals (Sweden)

    Csinszka K.-Ivácson A.-

    2016-09-01

    Full Text Available Crown or root perforation, ledge formation, fractured instruments and perforation of the roots are the most important accidents which appear during endodontic therapy. Our objective was to evaluate the value of digital intraoral periapical radiographs compared to cone beam computed tomography images (CBCT used to diagnose some procedural accidents. Material and methods: Eleven extracted molars were used in this study. A total of 18 perforations and 13 ledges were created artifically and 10 instruments were fractured in the root canals. Digital intraoral periapical radiographs from two angles and CBCT scans were made with the teeth fixed in position. The images were evaluated and the number of detected accidents were stated in percentages. Statistical analysis was performed using the chi square-test. Results: On digital periapical radiographs the evaluators identified 12 (66.66% perforations, 10 (100 % separated instruments and 10 (76.9% created ledges. The CBCT scans made possible the recognition of 17 (94.66 % perforations, 9 (90 % separated instruments and 13 (100% ledges. The totally recognized accidental procedures showed significant differences between the two groups. (p<0.05 Conclusion: Digital periapical radiographs are the most common imaging modalities used during endodontic treatments. Though, the CBCT allows a better identification of the procedural accidents.

  10. Understanding the Electronic Structure of 4d Metal Complexes: From Molecular Spinors to L-Edge Spectra of a di-Ru Catalyst

    Energy Technology Data Exchange (ETDEWEB)

    Alperovich, Igor; Smolentsev, Grigory; Moonshiram, Dooshaye; Jurss, Jonah W.; Concepcion, Javier J.; Meyer, Thomas J.; Soldatov, Alexander; Pushkar, Yulia (UNC); (Purdue); (SFU-Russia); (Lund)

    2015-09-17

    L{sub 2,3}-edge X-ray absorption spectroscopy (XAS) has demonstrated unique capabilities for the analysis of the electronic structure of di-Ru complexes such as the blue dimer cis,cis-[Ru{sub 2}{sup III}O(H{sub 2}O){sub 2}(bpy){sub 4}]{sup 4+} water oxidation catalyst. Spectra of the blue dimer and the monomeric [Ru(NH{sub 3}){sub 6}]{sup 3+} model complex show considerably different splitting of the Ru L{sub 2,3} absorption edge, which reflects changes in the relative energies of the Ru 4d orbitals caused by hybridization with a bridging ligand and spin-orbit coupling effects. To aid the interpretation of spectroscopic data, we developed a new approach, which computes L{sub 2,3}-edges XAS spectra as dipole transitions between molecular spinors of 4d transition metal complexes. This allows for careful inclusion of the spin-orbit coupling effects and the hybridization of the Ru 4d and ligand orbitals. The obtained theoretical Ru L{sub 2,3}-edge spectra are in close agreement with experiment. Critically, existing single-electron methods (FEFF, FDMNES) broadly used to simulate XAS could not reproduce the experimental Ru L-edge spectra for the [Ru(NH{sub 3}){sub 6}]{sup 3+} model complex nor for the blue dimer, while charge transfer multiplet (CTM) calculations were not applicable due to the complexity and low symmetry of the blue dimer water oxidation catalyst. We demonstrated that L-edge spectroscopy is informative for analysis of bridging metal complexes. The developed computational approach enhances L-edge spectroscopy as a tool for analysis of the electronic structures of complexes, materials, catalysts, and reactive intermediates with 4d transition metals.

  11. Mechanics and complications of reverse shoulder arthroplasty: morse taper failure analysis and prospective rectification

    International Nuclear Information System (INIS)

    Hoskin, HLD; Furie, E; Ganey, TM; Schlatterer, DR; Collins, W

    2017-01-01

    Since Sir John Charnley began his monumental hip arthroplasty work in 1958, clinical researchers have been incrementally improving longevity and functionality of total joint systems, although implant failure occurs on occasion. The purpose of this study is to report the fracture of the humeral tray Morse taper of a reverse total shoulder system (RTSS), which to date has not been reported with metallurgic analysis for any RTSS. There was no reported antecedent fall, motor vehicle collision, or other traumatic event prior to implant fracture in this case. Analysis was performed on the retrieved failed implant by Scanning Electron Microscopy (SEM) and Electron Dispersion Spectroscopy (EDS) in an attempt to determine the failure method, as well as to offer improvements for future implants. At the time of revision surgery all explants were retained from the left shoulder of a 61-year old male who underwent a non-complicated RTSS 4 years prior. The explants, particularly the cracked humeral tray, were processed as required for SEM and EDS. Analysis was performed on the failure sites in order to determine the chemical composition of the different parts of the implant, discover the chemical composition of the filler metal used during the electron beam welding process, and to detect any foreign elements that could suggest corrosion or other evidence of failure etiology. Gross visual inspection of all explants revealed that implant failure was a result of dissociation of the taper from the humeral tray at the weld, leaving the Morse taper embedded in the humeral stem while the tray floated freely in the patient’s shoulder. SEM further confirmed the jagged edges noted grossly at the weld fracture site, both suggesting failure due to torsional forces. EDS detected elevated levels of carbon and oxygen at the fracture site on the taper only and not on the humeral tray. In order to determine the origin of the high levels of C and O, it was considered that in titanium alloys, C

  12. Mechanics and complications of reverse shoulder arthroplasty: morse taper failure analysis and prospective rectification

    Science.gov (United States)

    Hoskin, HLD; Furie, E.; Collins, W.; Ganey, TM; Schlatterer, DR

    2017-05-01

    Since Sir John Charnley began his monumental hip arthroplasty work in 1958, clinical researchers have been incrementally improving longevity and functionality of total joint systems, although implant failure occurs on occasion. The purpose of this study is to report the fracture of the humeral tray Morse taper of a reverse total shoulder system (RTSS), which to date has not been reported with metallurgic analysis for any RTSS. There was no reported antecedent fall, motor vehicle collision, or other traumatic event prior to implant fracture in this case. Analysis was performed on the retrieved failed implant by Scanning Electron Microscopy (SEM) and Electron Dispersion Spectroscopy (EDS) in an attempt to determine the failure method, as well as to offer improvements for future implants. At the time of revision surgery all explants were retained from the left shoulder of a 61-year old male who underwent a non-complicated RTSS 4 years prior. The explants, particularly the cracked humeral tray, were processed as required for SEM and EDS. Analysis was performed on the failure sites in order to determine the chemical composition of the different parts of the implant, discover the chemical composition of the filler metal used during the electron beam welding process, and to detect any foreign elements that could suggest corrosion or other evidence of failure etiology. Gross visual inspection of all explants revealed that implant failure was a result of dissociation of the taper from the humeral tray at the weld, leaving the Morse taper embedded in the humeral stem while the tray floated freely in the patient’s shoulder. SEM further confirmed the jagged edges noted grossly at the weld fracture site, both suggesting failure due to torsional forces. EDS detected elevated levels of carbon and oxygen at the fracture site on the taper only and not on the humeral tray. In order to determine the origin of the high levels of C and O, it was considered that in titanium alloys, C

  13. Early Outcomes of Revision Surgery for Taper Corrosion of Dual Taper Total Hip Arthroplasty in 187 Patients.

    Science.gov (United States)

    Dimitriou, Dimitris; Liow, Ming Han Lincoln; Tsai, Tsung-Yuan; Leone, William A; Li, Guoan; Kwon, Young-Min

    2016-07-01

    Modular dual taper femoral neck designs have been associated with taper corrosion requiring revision surgery. However, outcomes after revision dual taper total hip arthroplasty in patients with symptomatic adverse local tissue reaction due to taper corrosion remain largely unknown. A total of 198 revision surgeries in 187 patients with dual taper femoral stem total hip arthroplasty with minimum 12-month follow-up were evaluated. At mean follow-up of 18 months, at least 1 complication had occurred in 39 patients (20%) of 198 revisions. Single episode of dislocation, treated with close reduction, occurred in 16, whereas 2 patients required rerevision due to multiple dislocations. Infection requiring rerevision occurred in 3 patients. Adverse local tissue reaction recurrence requiring reoperation occurred in 6 patients. Implant survivorship for revision for any cause was 86% at 30 months. The reoperation rate of revised dual taper was 8% (16 out of 198 hips). The median serum levels of cobalt, chromium, and cobalt/chromium ratio decreased (P revisions (8%), suggesting the importance of a systematic evaluation of these patients including metal ion levels and metal artifact reduction sequence magnetic resonance imaging in optimizing revision outcome, as early diagnosis will facilitate the initiation of appropriate treatment before significant adverse tissue necrosis. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Gap and channeled plasmons in tapered grooves: a review

    DEFF Research Database (Denmark)

    Smith, C. L. C.; Stenger, Nicolas; Kristensen, Anders

    2015-01-01

    Tapered metallic grooves have been shown to support plasmons - electromagnetically coupled oscillations of free electrons at metal-dielectric interfaces - across a variety of configurations and V-like profiles. Such plasmons may be divided into two categories: gap-surface plasmons (GSPs) that are......Tapered metallic grooves have been shown to support plasmons - electromagnetically coupled oscillations of free electrons at metal-dielectric interfaces - across a variety of configurations and V-like profiles. Such plasmons may be divided into two categories: gap-surface plasmons (GSPs......) that are confined laterally between the tapered groove sidewalls and propagate either along the groove axis or normal to the planar surface, and channeled plasmon polaritons (CPPs) that occupy the tapered groove profile and propagate exclusively along the groove axis. Both GSPs and CPPs exhibit an assortment...... platform to explore the fundamental science of plasmon excitations and their interactions. In this Review, we provide a research status update of plasmons in tapered grooves, starting with a presentation of the theory and important features of GSPs and CPPs, and follow with an overview of the broad range...

  15. Artificial Material Integrated Ultra-wideband Tapered Slot Antenna for Gain Enhancement with Band Notch Characteristics

    Directory of Open Access Journals (Sweden)

    R. Singha

    2018-04-01

    Full Text Available The gain of the ultra-wideband tapered slot antenna (TSA is enhanced by using broadband artificial material with band notch characteristics. The proposed artificial material unit cell is designed by fabricating non-resonant three S-shaped parallel metallic line on single side of the dielectric substrate which provides a longer current path compared to the parallel-line structure. The proposed S-shaped structure is printed on the top side of the tapered slot antenna in the extended substrate periodically. The effective refractive index of the artificial material is lower than antenna substrate and phase velocity in the region of artificial material is much higher than the other region. Therefore, the proposed artificial material acts like a beam focusing lens. The band notch at 5.5 GHz is achieved by creating a split ring resonator (SRR slot near the balun. The basic and artificial material loaded TSAs are fabricated and the measurement results show that the gain of the basic antenna has been increased by 1.6 dBi. At the same time, the proposed antenna achieves a VSWR below 2 from 3 to 11 GHz except at 5.5 GHz with a notch band from 5.1 to 5.8 GHz for band rejection of wireless local area network (WLAN application.

  16. Tapering Practices of Strongman Athletes: Test-Retest Reliability Study.

    Science.gov (United States)

    Winwood, Paul W; Pritchard, Hayden J; Keogh, Justin Wl

    2017-10-31

    Little is currently known about the tapering practices of strongman athletes. We have developed an Internet-based comprehensive self-report questionnaire examining the training and tapering practices of strongman athletes. The objective of this study was to document the test-retest reliability of questions associated with the Internet-based comprehensive self-report questionnaire on the tapering practices of strongman athletes. The information will provide insight on the reliability and usefulness of the online questionnaire for use with strongman athletes. Invitations to complete an Internet questionnaire were sent via Facebook Messenger to identified strongman athletes. The survey consisted of four main areas of inquiry, including demographics and background information, training practices, tapering, and tapering practices. Of the 454 athletes that completed the survey over the 8-week period, 130 athletes responded on Facebook Messenger indicating that they intended to complete, or had completed, the survey. These participants were asked if they could complete the online questionnaire a second time for a test-retest reliability analysis. Sixty-four athletes (mean age 33.3 years, standard deviation [SD] 7.7; mean height 178.2 cm, SD 11.0; mean body mass 103.7 kg, SD 24.8) accepted this invitation and completed the survey for the second time after a minimum 7-day period from the date of their first completion. Agreement between athlete responses was measured using intraclass correlation coefficients (ICCs) and kappa statistics. Confidence intervals (at 95%) were reported for all measures and significance was set at P<.05. Test-retest reliability for demographic and training practices items were significant (P<.001) and showed excellent (ICC range=.84 to .98) and fair to almost perfect agreement (κ range=.37-.85). Moderate to excellent agreements (ICC range=.56-.84; P<.01) were observed for all tapering practice measures except for the number of days athletes

  17. Exponet taper-shape models to describe tree trunks

    Directory of Open Access Journals (Sweden)

    Valdir Carlos Lima de Andrade

    2014-12-01

    Full Text Available This study evaluated exponent taper-shape models and other types applied in Brazil. Data from 270 sample trees scaled-hybrid Eucalyptus urophylla and Eucalyptus grandis were used as a studying case with 18 taper types models: simple (2, biomathematics (4, segmented (2 and exponent-form (10. It was adopted the analysis of the residual distribution and statistics: multiple linear correlation, residual standard error, percentage of no significant parcels in a completely randomized split plot and average error Dunnett, both at the level of 5% significance level. It was concluded that models of taper-shape exponents, in general, are superior to other types, the segmented model of Clark et al. is superior to Max and Burkhart biomathematics and the model developed in this paper, is better than the other biomathematics evaluated.

  18. The effect of tapering on a magnetocaloric regenerator bed

    DEFF Research Database (Denmark)

    Dallolio, Stefano; Lei, Tian; Engelbrecht, Kurt

    2017-01-01

    To design a high efficiency magnetocaloric heat pump for the residential sector, we focused on the improvement of the performance of the regenerator bed. In particular, placing the regenerators circumferentially on a plane, we decided to use tapered regenerators instead of the straight channel ones....... Therefore, this paper investigates the effect of the tapering of the regenerators, which exhibit better air-gap utilization. Several simulations using a 1D AMR model were run to study the performance of the tapered regenerator, and the results were compared to the case of the straight regenerator bed....... Moreover, the temperature span was held fixed at 25 K, and the working temperature of the regenerator was shifted to study the sensitivity to the variation of the working conditions. This paper considers a 10-layer regenerator, with Curie temperature (TC) spacing of 2.5 K....

  19. Tapering Practices of Strongman Athletes: Test-Retest Reliability Study

    Science.gov (United States)

    Pritchard, Hayden J; Keogh, Justin WL

    2017-01-01

    Background Little is currently known about the tapering practices of strongman athletes. We have developed an Internet-based comprehensive self-report questionnaire examining the training and tapering practices of strongman athletes. Objective The objective of this study was to document the test-retest reliability of questions associated with the Internet-based comprehensive self-report questionnaire on the tapering practices of strongman athletes. The information will provide insight on the reliability and usefulness of the online questionnaire for use with strongman athletes. Methods Invitations to complete an Internet questionnaire were sent via Facebook Messenger to identified strongman athletes. The survey consisted of four main areas of inquiry, including demographics and background information, training practices, tapering, and tapering practices. Of the 454 athletes that completed the survey over the 8-week period, 130 athletes responded on Facebook Messenger indicating that they intended to complete, or had completed, the survey. These participants were asked if they could complete the online questionnaire a second time for a test-retest reliability analysis. Sixty-four athletes (mean age 33.3 years, standard deviation [SD] 7.7; mean height 178.2 cm, SD 11.0; mean body mass 103.7 kg, SD 24.8) accepted this invitation and completed the survey for the second time after a minimum 7-day period from the date of their first completion. Agreement between athlete responses was measured using intraclass correlation coefficients (ICCs) and kappa statistics. Confidence intervals (at 95%) were reported for all measures and significance was set at PTest-retest reliability for demographic and training practices items were significant (P<.001) and showed excellent (ICC range=.84 to .98) and fair to almost perfect agreement (κ range=.37-.85). Moderate to excellent agreements (ICC range=.56-.84; P<.01) were observed for all tapering practice measures except for the number

  20. Single muscle fiber gene expression with run taper.

    Directory of Open Access Journals (Sweden)

    Kevin Murach

    Full Text Available This study evaluated gene expression changes in gastrocnemius slow-twitch myosin heavy chain I (MHC I and fast-twitch (MHC IIa muscle fibers of collegiate cross-country runners (n = 6, 20±1 y, VO₂max = 70±1 ml•kg-1•min-1 during two distinct training phases. In a controlled environment, runners performed identical 8 kilometer runs (30:18±0:30 min:s, 89±1% HRmax while in heavy training (∼72 km/wk and following a 3 wk taper. Training volume during the taper leading into peak competition was reduced ∼50% which resulted in improved race times and greater cross-section and improved function of MHC IIa fibers. Single muscle fibers were isolated from pre and 4 hour post run biopsies in heavily trained and tapered states to examine the dynamic acute exercise response of the growth-related genes Fibroblast growth factor-inducible 14 (FN14, Myostatin (MSTN, Heat shock protein 72 (HSP72, Muscle ring-finger protein-1 (MURF1, Myogenic factor 6 (MRF4, and Insulin-like growth factor 1 (IGF1 via qPCR. FN14 increased 4.3-fold in MHC IIa fibers with exercise in the tapered state (P<0.05. MSTN was suppressed with exercise in both fiber types and training states (P<0.05 while MURF1 and HSP72 responded to running in MHC IIa and I fibers, respectively, regardless of training state (P<0.05. Robust induction of FN14 (previously shown to strongly correlate with hypertrophy and greater overall transcriptional flexibility with exercise in the tapered state provides an initial molecular basis for fast-twitch muscle fiber performance gains previously observed after taper in competitive endurance athletes.

  1. Design of Humidity Sensors Based on Tapered Optical Fibers

    Science.gov (United States)

    Corres, Jesús M.; Arregui, Francisco J.; Matias, Ignacio R.

    2006-11-01

    In this paper, the response of a tapered optical fiber humidity sensor is optimized, attending to the thickness of the sensitive coating, the dimensions of the taper, the light source, and the utilization of sensitive materials with different refractive indexes. The main novelty of this study is that the thickness of the sensitive layer is on the order of magnitude of the light wavelength used to excite the sensor. It is shown here that an estimation of the sensor sensitivity can be deducted from the transmitted optical power curve obtained during the layer-by-layer construction process. Theoretical and experimental results are presented.

  2. Tapered amplifier laser with frequency-shifted feedback

    Directory of Open Access Journals (Sweden)

    A. Bayerle, S. Tzanova, P. Vlaar, B. Pasquiou, F. Schreck

    2016-10-01

    Full Text Available We present a frequency-shifted feedback (FSF laser based on a tapered amplifier. The laser operates as a coherent broadband source with up to 370GHz spectral width and 2.3us coherence time. If the FSF laser is seeded by a continuous-wave laser a frequency comb spanning the output spectrum appears in addition to the broadband emission. The laser has an output power of 280mW and a center wavelength of 780nm. The ease and flexibility of use of tapered amplifiers makes our FSF laser attractive for a wide range of applications, especially in metrology.

  3. FDML swept source at 1060 nm using a tapered amplifier

    DEFF Research Database (Denmark)

    Marschall, Sebastian; Klein, Thomas; Wieser, Wolfgang

    2010-01-01

    We present a novel frequency-swept light source working at 1060nm that utilizes a tapered amplifier as gain medium. These devices feature significantly higher saturation power than conventional semiconductor optical amplifiers and can thus improve the limited output power of swept sources...... in this wavelength range. We demonstrate that a tapered amplifier can be integrated into a fiber-based swept source and allows for high-speed FDML operation. The developed light source operates at a sweep rate of 116kHz with an effective average output power in excess of 30mW. With a total sweep range of 70 nm...

  4. Efficacy of ProTaper and Mtwo Retreatment Files in Removal of Gutta-percha and GuttaFlow from Root Canals

    Science.gov (United States)

    Khedmat, Sedigheh; Azari, Abbas; Shamshiri, Ahmad Reza; Fadae, Mehdi; Bashizadeh Fakhar, Hoorieh

    2016-01-01

    Introduction: The aim of this in vitro study was to compare the efficacy of ProTaper retreatment (ProTaper R) and Mtwo retreatment (Mtwo R) files in removing gutta-percha and GuttaFlow from endodontically treated straight root canals. Methods and Materials: The root canals of 60 human mandibular single-rooted premolars were prepared and randomly divided into two groups (n=30). In groups A and B the root canals were obturated using lateral condensation of gutta-percha plus AH 26 and GuttaFlow, respectively. The canal orifices were temporarily sealed and the roots were incubated for 3 months at 37ºC and 100% humidity. Primary cone-beam computed tomography (CBCT) images were taken after incubation period. The specimens in each group were randomly divided into two subgroups (n=15). ProTaper R files (D1, D2, and D3) were used in groups A1 and B1 while Mtwo R files (25/0.05 and 15/0.05) were used in groups A2 and B2. The time required to extirpate the root filling was also recorded. After retreatment, another CBCT scan was taken at the same position. The volume of remaining filling materials inside the canals was calculated before and after retreatment. The data was analyzed using the two-way ANOVA and independent t-test. Results: The remaining filling materials in the canals treated with ProTaper were less than Mtwo. The remaining volume of GuttaFlow was less than gutta-percha regardless of the system applied. Mtwo R files removed root fillings faster than ProTaper R. Conclusion: ProTaper R removed filling material more efficiently compared to Mtwo R which required less time to remove root filling material. PMID:27471528

  5. Optimization of Tapered Photonic Crystal Fibers for Blue-Enhanced Supercontinuum Generation

    DEFF Research Database (Denmark)

    Møller, Uffe; Sørensen, Simon Toft; Larsen, Casper

    2012-01-01

    Tapering of photonic crystal fibers is an effective way of shifting the dispersive wavelength edge of a supercontinuum spectrum down in the deep-blue. We discuss the optimum taper profile for blue-enhanced supercontinuum generation....

  6. 76 FR 76143 - Tapered Roller Bearings and Parts Thereof, Finished and Unfinished, From the People's Republic of...

    Science.gov (United States)

    2011-12-06

    ..., the United Steel, Paper and Forestry, Rubber, Manufacturing, Energy, Allied Industrial and Service... hanger units incorporating tapered roller bearings; and tapered roller housings (except pillow blocks...

  7. STIR-Physics: Cold Atoms and Nanocrystals in Tapered Nanofiber and High-Q Resonator Potentials

    Science.gov (United States)

    2016-11-02

    STIR- Physics : Cold Atoms and Nanocrystals in Tapered Nanofiber and High-Q Resonator Potentials We worked on a tapered fiber in cold atomic cloud...reviewed journals: Number of Papers published in non peer-reviewed journals: Final Report: STIR- Physics : Cold Atoms and Nanocrystals in Tapered Nanofiber...developing tapered fiber mount at the end of the program Side Effort: Explored pulse reflection from a temporally moving boundary. There is a temporal

  8. Apically extruded debris during root canal preparation using ProTaper Gold, ProTaper Universal, ProTaper Next, and RECIPROC instruments.

    Science.gov (United States)

    Cakici, Fatih; Cakici, Elif B; Küçükekenci, Funda F; Uygun, Ahmet D; Arslan, Hakan

    2016-05-16

    The aim of this study was to determine the amount of apically extruded debris during root canal preparation with ProTaper Gold (PTG) (Dentsply Maillefer, Ballaigues, Switzerland), ProTaper Universal (PTU) (Dentsply Maillefer), ProTaper Next (PTN) (Dentsply Maillefer), and RECIPROC (VDW, Munich, Germany) in curved canals. Eighty human mandibular molar teeth were divided into 4 groups according to the system used for root canal preparation: PTG, PTU, PTN, and RECİPROC groups. The mean weight of extruded debris was statistically analyzed using one-way analysis of variance and post-hoc Tukey's test (α = 0.05). The PTU was associated with significantly more extruded debris than the PTG, PTN, and RECIPROC (p<0.05). The PTG was associated with significantly more extruded debris than the PTN and RECIPROC (p<0.05), whereas no significant difference was found between the RECIPROC and PTN (p>0.05). All systems caused apical debris extrusion during curved canal preparations. However, the PTG, PTN, and RECIPROC systems resulted in significantly less debris extrusion than the PTU system.

  9. The effects of autoclave sterilization on the cyclic fatigue resistance of ProTaper Universal, ProTaper Next, and ProTaper Gold nickel-titanium instruments.

    Science.gov (United States)

    Özyürek, Taha; Yılmaz, Koray; Uslu, Gülşah

    2017-11-01

    It was aimed to compare the cyclic fatigue resistances of ProTaper Universal (PTU), ProTaper Next (PTN), and ProTaper Gold (PTG) and the effects of sterilization by autoclave on the cyclic fatigue life of nickel-titanium (NiTi) instruments. Eighty PTU, 80 PTN, and 80 PTG were included to the present study. Files were tested in a simulated canal. Each brand of the NiTi files were divided into 4 subgroups: group 1, as received condition; group 2, pre-sterilized instruments exposed to 10 times sterilization by autoclave; group 3, instruments tested were sterilized after being exposed to 25%, 50%, and 75% of the mean cycles to failure, then cycled fatigue test was performed; group 4, instruments exposed to the same experiment with group 3 without sterilization. The number of cycles to failure (NCF) was calculated. The data was statistically analyzed by using one-way analysis of variance and post hoc Tukey tests. PTG showed significantly higher NCF than PTU and PTN in group 1 ( p Autoclaving increased the cyclic fatigue resistances of PTN and PTG.

  10. Deep-blue supercontinnum sources with optimum taper profiles – verification of GAM

    DEFF Research Database (Denmark)

    Sørensen, Simon Toft; Møller, Uffe; Larsen, Casper

    2012-01-01

    We use an asymmetric 2 m draw-tower photonic crystal fiber taper to demonstrate that the taper profile needs careful optimisation if you want to develop a supercontinuum light source with as much power as possible in the blue edge of the spectrum. In particular we show, that for a given taper len...

  11. K- and L-edge X-ray Absorption Spectroscopy (XAS) and Resonant Inelastic X-ray Scattering (RIXS) Determination of Differential Orbital Covalency (DOC) of Transition Metal Sites.

    Science.gov (United States)

    Baker, Michael L; Mara, Michael W; Yan, James J; Hodgson, Keith O; Hedman, Britt; Solomon, Edward I

    2017-08-15

    Continual advancements in the development of synchrotron radiation sources have resulted in X-ray based spectroscopic techniques capable of probing the electronic and structural properties of numerous systems. This review gives an overview of the application of metal K-edge and L-edge X-ray absorption spectroscopy (XAS), as well as K resonant inelastic X-ray scattering (RIXS), to the study of electronic structure in transition metal sites with emphasis on experimentally quantifying 3d orbital covalency. The specific sensitivities of K-edge XAS, L-edge XAS, and RIXS are discussed emphasizing the complementary nature of the methods. L-edge XAS and RIXS are sensitive to mixing between 3d orbitals and ligand valence orbitals, and to the differential orbital covalency (DOC), that is, the difference in the covalencies for different symmetry sets of the d orbitals. Both L-edge XAS and RIXS are highly sensitive to and enable separation of and donor bonding and back bonding contributions to bonding. Applying ligand field multiplet simulations, including charge transfer via valence bond configuration interactions, DOC can be obtained for direct comparison with density functional theory calculations and to understand chemical trends. The application of RIXS as a probe of frontier molecular orbitals in a heme enzyme demonstrates the potential of this method for the study of metal sites in highly covalent coordination sites in bioinorganic chemistry.

  12. Ab Initio Calculations of X-ray Spectra : Atomic Multiplet and Molecular Orbital Effects in a Multiconfigurational SCF Approach to the L-Edge Spectra of Transition Metal Complexes

    NARCIS (Netherlands)

    Josefsson, Ida; Kunnus, Kristjan; Schreck, Simon; Foehlisch, Alexander; de Groot, Frank; Wernet, Philippe; Odelius, Michael

    2012-01-01

    A new ab initio approach to the calculation of X-ray spectra is demonstrated. It combines a high-level quantum chemical description of the chemical interactions and local atomic multiplet effects. We show here calculated L-edge X-ray absorption (XA) and resonant inelastic X-ray scattering spectra

  13. Tapered composite likelihood for spatial max-stable models

    KAUST Repository

    Sang, Huiyan

    2014-05-01

    Spatial extreme value analysis is useful to environmental studies, in which extreme value phenomena are of interest and meaningful spatial patterns can be discerned. Max-stable process models are able to describe such phenomena. This class of models is asymptotically justified to characterize the spatial dependence among extremes. However, likelihood inference is challenging for such models because their corresponding joint likelihood is unavailable and only bivariate or trivariate distributions are known. In this paper, we propose a tapered composite likelihood approach by utilizing lower dimensional marginal likelihoods for inference on parameters of various max-stable process models. We consider a weighting strategy based on a "taper range" to exclude distant pairs or triples. The "optimal taper range" is selected to maximize various measures of the Godambe information associated with the tapered composite likelihood function. This method substantially reduces the computational cost and improves the efficiency over equally weighted composite likelihood estimators. We illustrate its utility with simulation experiments and an analysis of rainfall data in Switzerland.

  14. Theoretical Analysis and Preparation of Tapered Suspended Core Microstructure Fibers

    Czech Academy of Sciences Publication Activity Database

    Martan, Tomáš; Kaňka, Jiří; Kašík, Ivan; Matějec, Vlastimil

    2009-01-01

    Roč. 3, č. 3 (2009), s. 233-249 ISSN 1559-9612 Institutional research plan: CEZ:AV0Z20670512 Keywords : tapered fibers * optical sensors Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 0.354, year: 2009

  15. Efficacy of a modified tapering protocol on swimming performance ...

    African Journals Online (AJOL)

    Performance assessment following tapering consisted of 2 swims over a distance of 200 m, with a recovery period of 5 hours between swims. After resuming normal ... Total time and split times for each length, stroke rate, distance per stroke, and stroke index in a performance swim were determined as well as heart rate (HR) ...

  16. Sensitive Leptospira DNA Detection using Tapered Optical Fiber Sensor.

    Science.gov (United States)

    Zainuddin, N H; Chee, H Y; Ahmad, M Z; Mahdi, M A; Abu Bakar, M H; Yaacob, M H

    2018-03-23

    This paper presents the development of tapered optical fiber sensor to detect a specific Leptospira bacteria DNA. The bacteria causes Leptospirosis, a deadly disease but with common early flu-like symptoms. Optical single mode fiber (SMF) of 125 μm diameter is tapered to produce 12 μm waist diameter and 15 cm length. The novel DNA-based optical fiber sensor is functionalised by incubating the tapered region with sodium hydroxide (NaOH), (3-Aminopropyl) triethoxysilane (APTES) and glutaraldehyde. Probe DNA is immobilized onto the tapered region and subsequently hybridized by its complementary DNA. The transmission spectra of the DNA-based optical fiber sensor is measured in the 1500 - 1600 nm wavelength range. It is discovered that the shift of the wavelength in the SMF sensor is linearly proportional with the increase in the complementary DNA concentrations from 0.1 nM to 1.0 nM. The sensitivity of the sensor towards DNA is measured to be 1.2862 nm/nM and able to detect as low as 0.1 fM. The sensor indicates high specificity when only minimal shift is detected for non-complementary DNA testing. The developed sensor is able to distinguish between actual DNA of Leptospira serovars (Canicola and Copenhageni) against Clostridium difficile (control sample) at very low (femtomolar) target concentrations. This article is protected by copyright. All rights reserved.

  17. Tree taper models for Cupressus lusitanica plantations in Ethiopia ...

    African Journals Online (AJOL)

    ... found to vary from tree to tree and also appear to depend on tree size. The results from both the Monte Carlo and mixed effects modeling study seem to indicate the need to estimate p from the data. Keywords: Cupressus lusitanica; mixed effects modeling; Monte Carlo; tree taper. Southern Forests 2008, 70(3): 193–203 ...

  18. Tapered optical fiber sensor for chemical pollutants detection in seawater

    Science.gov (United States)

    Irigoyen, Maite; Sánchez-Martin, Jose Antonio; Bernabeu, Eusebio; Zamora, Alba

    2017-04-01

    Three tapered silica optical fibers, uncoated and coated with metallic (Al or Cu) and dielectric layers (TiO2), are employed to determine the presence of oil and Hazardous and Noxious Substances (HNS from now on) in water, by means of the measurement of their spectral transmittance. With our experimental assembly, the presence of oil and HNS spills can be detected employing the three different kinds of tapers, since the complete range of refractive indices of the pollutants (1.329-1.501) is covered with these tapers. The most suitable spectral range to detect the presence of a chemical pollutant in seawater has been identified and a complete spectral characterization of the three types of optical fiber tapers has been carried out. The results obtained show that, in general terms, these devices working together can be employed for the early detection of oil and HNS spills in seawater in a marine industrial environment. These sensors have many advantages, such as its low cost, its simplicity and versatility (with interesting properties as quick response and repeatability), and especially that they can be self-cleaned with seawater in motion.

  19. compatible volume-taper equations for predicting merchantable ...

    African Journals Online (AJOL)

    ADMIN

    On the other hand they noted that volume- based systems, if derived from sufficiently unbiased volume equations will always be satisfactory for total volume estimation. The purpose of this study is, therefore, to develop a compatible volume and taper system for. Cupressus lusitanica stands in Munessa Shashemene. Forest ...

  20. Compatible volume-taper equations for predicting merchantable ...

    African Journals Online (AJOL)

    Compatible systems of merchantable total tree cubic volume and stem taper equations are derived by integrating an existing volume equation. The systems are developed to yield volume at any merchantable length, total volume and for any merchantable top diameter. It is also demonstrated that the most common types of ...

  1. Taper and volume equations for selected Appalachian hardwood species

    Science.gov (United States)

    A. Jeff Martin

    1981-01-01

    Coefficients for five taper/volume models are developed for 18 Appalachian hardwood species. Each model can be used to estimate diameter at any point on the bole, height to any preselected diameter, and cubic-foot volume between any two points on the bole. The resulting equations were tested on six sets of independent data and an evaluation of these tests is included,...

  2. Drug taper during long-term video-EEG monitoring

    DEFF Research Database (Denmark)

    Guld, A. T.; Sabers, A.; Kjaer, T. W.

    2017-01-01

    Objectives: Anti-epileptic drugs (AED) are often tapered to reduce the time needed to record a sufficient number of seizure during long-term video-EEG monitoring (LTM). Fast AED reduction is considered less safe, but few studies have examined this. Our goal is to examine whether the rate of AED r...

  3. Power dependence of supercontinuum noise in uniform and tapered PCFs

    DEFF Research Database (Denmark)

    Møller, Uffe; Sørensen, Simon Toft; Jakobsen, C.

    2012-01-01

    We experimentally investigate the noise properties of picosecond supercontinuum spectra generated at different power levels in uniform and tapered photonic crystal fibers. We show that the noise at the spectral edges of the generated supercontinuum is at a constant level independent on the pump p...

  4. How a dependent's variable non-randomness affects taper equation ...

    African Journals Online (AJOL)

    In order to apply the least squares method in regression analysis, the values of the dependent variable Y should be random. In an example of regression analysis linear and nonlinear taper equations, which estimate the diameter of the tree dhi at any height of the tree hi, were compared. For each tree the diameter at the ...

  5. Computational model on pulsatile flow of blood through a tapered ...

    Indian Academy of Sciences (India)

    S PRIYADHARSHINI

    2017-11-02

    Nov 2, 2017 ... Abstract. An unsteady two-fluid model of blood flow through a tapered arterial stenosis with variable vis- cosity in the presence of variable magnetic field has been analysed in the present paper. In this article, blood in the core region is assumed to obey the law of Jeffrey fluid and plasma in the peripheral ...

  6. Characterization of tapered polymer optical fibers under side illumination for fluorescence sensing applications

    Science.gov (United States)

    Pulido, C.; Esteban, Ó.

    2011-05-01

    In this work we present the fabrication and characterization of tapered polymer fibers used as fluorescence based sensors with a side-illumination arrangement. The fabrication method consists of a travelling-heater that gives a tight control of the tapered fibers parameters, namely the taper waist and the profile of the transition length between the unaltered fiber and the taper waist. Furthermore, a different approach for using fluorophores in fluorescence based sensors has been developed. With our method, we can locally introduce a fluorescent dye inside the taper region, which could lead to the generation of cuasi-distributed sensors for lengths of hundred of meters.

  7. Refractive index sensors based on the fused tapered special multi-mode fiber

    Science.gov (United States)

    Fu, Xing-hu; Xiu, Yan-li; Liu, Qin; Xie, Hai-yang; Yang, Chuan-qing; Zhang, Shun-yang; Fu, Guang-wei; Bi, Wei-hong

    2016-01-01

    In this paper, a novel refractive index (RI) sensor is proposed based on the fused tapered special multi-mode fiber (SMMF). Firstly, a section of SMMF is spliced between two single-mode fibers (SMFs). Then, the SMMF is processed by a fused tapering machine, and a tapered fiber structure is fabricated. Finally, a fused tapered SMMF sensor is obtained for measuring external RI. The RI sensing mechanism of tapered SMMF sensor is analyzed in detail. For different fused tapering lengths, the experimental results show that the RI sensitivity can be up to 444.517 81 nm/RIU in the RI range of 1.334 9—1.347 0. The RI sensitivity is increased with the increase of fused tapering length. Moreover, it has many advantages, including high sensitivity, compact structure, fast response and wide application range. So it can be used to measure the solution concentration in the fields of biochemistry, health care and food processing.

  8. High energy gain of trapped electrons in a tapered, diffraction-dominated inverse-free-electron laser.

    Science.gov (United States)

    Musumeci, P; Tochitsky, S Ya; Boucher, S; Clayton, C E; Doyuran, A; England, R J; Joshi, C; Pellegrini, C; Ralph, J E; Rosenzweig, J B; Sung, C; Tolmachev, S; Travish, G; Varfolomeev, A A; Varfolomeev, A A; Yarovoi, T; Yoder, R B

    2005-04-22

    Energy gain of trapped electrons in excess of 20 MeV has been demonstrated in an inverse-free-electron-laser (IFEL) accelerator experiment. A 14.5 MeV electron beam is copropagated with a 400 GW CO2 laser beam in a 50 cm long undulator strongly tapered in period and field amplitude. The Rayleigh range of the laser, approximately 1.8 cm, is much shorter than the undulator length yielding a diffraction-dominated interaction. Experimental results on the dependence of the acceleration on injection energy, laser focus position, and laser power are discussed. Simulations, in good agreement with the experimental data, show that most of the energy gain occurs in the first half of the undulator at a gradient of 70 MeV/m and that the structure in the measured energy spectrum arises because of higher harmonic IFEL interaction in the second half of the undulator.

  9. High Energy Gain of Trapped Electrons in a Tapered, Diffraction-Dominated Inverse-Free-Electron Laser

    Science.gov (United States)

    Musumeci, P.; Tochitsky, S. Ya.; Boucher, S.; Clayton, C. E.; Doyuran, A.; England, R. J.; Joshi, C.; Pellegrini, C.; Ralph, J. E.; Rosenzweig, J. B.; Sung, C.; Tolmachev, S.; Travish, G.; Varfolomeev, A. A.; Varfolomeev, A. A.; Yarovoi, T.; Yoder, R. B.

    2005-04-01

    Energy gain of trapped electrons in excess of 20 MeV has been demonstrated in an inverse-free-electron-laser (IFEL) accelerator experiment. A 14.5 MeV electron beam is copropagated with a 400 GW CO2 laser beam in a 50 cm long undulator strongly tapered in period and field amplitude. The Rayleigh range of the laser, ˜1.8 cm, is much shorter than the undulator length yielding a diffraction-dominated interaction. Experimental results on the dependence of the acceleration on injection energy, laser focus position, and laser power are discussed. Simulations, in good agreement with the experimental data, show that most of the energy gain occurs in the first half of the undulator at a gradient of 70 MeV/m and that the structure in the measured energy spectrum arises because of higher harmonic IFEL interaction in the second half of the undulator.

  10. Nonlinear beam clean-up using resonantly enhanced sum-frequency mixing

    DEFF Research Database (Denmark)

    Karamehmedovic, Emir; Pedersen, Christian; Jensen, Ole Bjarlin

    2009-01-01

    We investigate the possibility of improving the beam quality and obtaining high conversion efficiency in nonlinear sum-frequency generation. A 765 nm beam from an external cavity tapered diode laser is single-passed through a nonlinear crystal situated in the high intracavity field of a 1342 nm N...

  11. Investigation of the beam impedance of a slowly varying waveguide

    International Nuclear Information System (INIS)

    Jones, R.M.; Heifets, S.A.

    1995-05-01

    A perturbation method is used to obtain analytic expressions for the multipole longitudinal and universe beam impedance for an arbitrary waveguide whose radius is slowly varying and for the specific case of a symmetric small-angle taper. This method is also applicable for a particle in a wiggler undergoing periodic motion

  12. Liquid crystal polymer substrate based wideband tapered step antenna

    Directory of Open Access Journals (Sweden)

    Boddapati Taraka Phani MADHAV

    2015-05-01

    Full Text Available Performance study of wideband tapered step antenna on liquid crystal polymer substrate material is presented. Bandwidth enhancement is achieved by adding step serrated ground on the front side of the model along with the radiating patch. The radiating patch seems to be the intersection of two half circles connected back to back. The lower half circle radius is more than upper half circle radius. Wideband tapered step antenna is designed on the liquid crystal polymer substrate (Ultralam 3850, εr = 2.9 with dimensions of 20×20×0.5 mm. Coplanar waveguide feeding is used in this model with feed line width of 2.6 mm and gap between feed line to ground plane of 0.5 mm.

  13. Shape matters: improved flight in tapered auto-rotating wings

    Science.gov (United States)

    Liu, Yucen; Vincent, Lionel; Kanso, Eva

    2017-11-01

    Many plants use gravity and wind to disperse their seeds. The shape of seed pods influence their aerodynamics. For example, Liana seeds form aerodynamic gliders and Sycamore trees release airborne ``helicopters.'' Here, we use carefully-controlled experiments and high-speed photography to examine dispersion by tumbling (auto-rotation) and we focus on the effect of geometry on flight characteristics. We consider four families of shapes: rectangular, elliptic, tapered, and sharp-tip wings, and we vary the span-to-chord ratio. We find that tapered wings exhibit extended flight time and range, that is, better performance. A quasi-steady two-dimensional model is used to highlight the mechanisms by which shape affects flight performance. These findings could have significant implications on linking seedpod designs to seed dispersion patterns as well as on optimizing wing design in active flight problems.

  14. Plasmonic Sensors Based on Doubly-Deposited Tapered Optical Fibers

    Directory of Open Access Journals (Sweden)

    Agustín González-Cano

    2014-03-01

    Full Text Available A review of the surface plasmon resonance (SPR transducers based on tapered fibers that have been developed in the last years is presented. The devices have proved their good performance (specifically, in terms of sensitivity and their versatility and they are a very good option to be considered as basis for any kind of chemical and biological sensor. The technology has now reached its maturity and here we summarize some of the characteristics of the devices produced.

  15. Portable fiber-optic taper coupled optical microscopy platform

    Science.gov (United States)

    Wang, Weiming; Yu, Yan; Huang, Hui; Ou, Jinping

    2017-04-01

    The optical fiber taper coupled with CMOS has advantages of high sensitivity, compact structure and low distortion in the imaging platform. So it is widely used in low light, high speed and X-ray imaging systems. In the meanwhile, the peculiarity of the coupled structure can meet the needs of the demand in microscopy imaging. Toward this end, we developed a microscopic imaging platform based on the coupling of cellphone camera module and fiber optic taper for the measurement of the human blood samples and ascaris lumbricoides. The platform, weighing 70 grams, is based on the existing camera module of the smartphone and a fiber-optic array which providing a magnification factor of 6x.The top facet of the taper, on which samples are placed, serves as an irregular sampling grid for contact imaging. The magnified images of the sample, located on the bottom facet of the fiber, are then projected onto the CMOS sensor. This paper introduces the portable medical imaging system based on the optical fiber coupling with CMOS, and theoretically analyzes the feasibility of the system. The image data and process results either can be stored on the memory or transmitted to the remote medical institutions for the telemedicine. We validate the performance of this cell-phone based microscopy platform using human blood samples and test target, achieving comparable results to a standard bench-top microscope.

  16. FDM Analysis for Blood Flow through Stenosed Tapered Arteries

    Directory of Open Access Journals (Sweden)

    Sankar DS

    2010-01-01

    Full Text Available Abstract A computational model is developed to analyze the unsteady flow of blood through stenosed tapered narrow arteries, treating blood as a two-fluid model with the suspension of all the erythrocytes in the core region as Herschel-Bulkley fluid and the plasma in the peripheral layer as Newtonian fluid. The finite difference method is employed to solve the resulting system of nonlinear partial differential equations. The effects of stenosis height, peripheral layer thickness, yield stress, viscosity ratio, angle of tapering and power law index on the velocity, wall shear stress, flow rate and the longitudinal impedance are analyzed. It is found that the velocity and flow rate increase with the increase of the peripheral layer thickness and decrease with the increase of the angle of tapering and depth of the stenosis. It is observed that the flow rate decreases nonlinearly with the increase of the viscosity ratio and yield stress. The estimates of the increase in the longitudinal impedance to flow are considerably lower for the two-fluid Herschel-Bulkley model compared with those of the single-fluid Herschel-Bulkley model. Hence, it is concluded that the presence of the peripheral layer helps in the functioning of the diseased arterial system.

  17. EFFECT OF TWO TAPERING METHODS ON INTERLEUKIN-6, CORTISOL AND PERFORMANCE IN ELITE MALE WRESTLER

    Directory of Open Access Journals (Sweden)

    A.B. Mehranpour

    2015-08-01

    Full Text Available Purpose : This study examined that effect of two types of tapering on interleukin-6(IL-6, cortisol and performance in elite male wrestler. Material : After 4 weeks of progressive training, wrestlers were randomly divided into three equal groups, 1-control group (N=10 continued performing progressive training for one week, 2-taper group 1 (N=10 continued with a 50% reduction in training volume for one week, 3-taper group 2 (N=10 continued with a 75% reduction in volume of training for one week .plasma blood IL-6 and cortisol levels were assayed from analysis obtained via standard ELISA. Also general strength of muscles was recorded as a performance test. All data were collected before and after progressive training and also after one week of tapering period. Results : There were significant reduction of IL-6 and cortisol levels in both tapering group comparing with control group (P≤0.05.There was significant reduction of IL-6 and cortisol levels among tapering 50% and tapering 75% after tapering period (P≤0.05. Also there was significant increase of general strength of muscles between tapering 75% and control group (P≤0.05. Conclusion : hence, one week tapering with 75% reduction in training volume after progressive training while the intensity kept high is effective strategy for reduction of IL-6, and cortisol levels and also increase performance. It seems that higher reduction of training volume when the intensity kept high is a good strategy for wrestler before main competition.

  18. Plasma lenses for focusing relativistic electron beams

    International Nuclear Information System (INIS)

    Govil, R.; Wheeler, S.; Leemans, W.

    1997-01-01

    The next generation of colliders require tightly focused beams with high luminosity. To focus charged particle beams for such applications, a plasma focusing scheme has been proposed. Plasma lenses can be overdense (plasma density, n p much greater than electron beam density, n b ) or underdense (n p less than 2 n b ). In overdense lenses the space-charge force of the electron beam is canceled by the plasma and the remaining magnetic force causes the electron beam to self-pinch. The focusing gradient is nonlinear, resulting in spherical aberrations. In underdense lenses, the self-forces of the electron beam cancel, allowing the plasma ions to focus the beam. Although for a given beam density, a uniform underdense lens produces smaller focusing gradients than an overdense lens, it produces better beam quality since the focusing is done by plasma ions. The underdense lens can be improved by tapering the density of the plasma for optimal focusing. The underdense lens performance can be enhanced further by producing adiabatic plasma lenses to avoid the Oide limit on spot size due to synchrotron radiation by the electron beam. The plasma lens experiment at the Beam Test Facility (BTF) is designed to study the properties of plasma lenses in both overdense and underdense regimes. In particular, important issues such as electron beam matching, time response of the lens, lens aberrations and shot-to-shot reproducibility are being investigated

  19. Influence of Temperature on Cyclic Fatigue Resistance of ProTaper Gold and ProTaper Universal Rotary Files.

    Science.gov (United States)

    Plotino, Gianluca; Grande, Nicola M; Mercadé Bellido, Montse; Testarelli, Luca; Gambarini, Gianluca

    2017-02-01

    The aim of this study was to evaluate the cyclic fatigue resistance of ProTaper Universal (PTU; Dentsply Maillefer, Baillagues, Switzerland) and ProTaper Gold (PTG, Dentsply Maillefer) nickel-titanium rotary files at room and intracanal temperatures. A total of 120 files were used to test the cyclic fatigue resistance of PTU (S1 and F2) and PTG (S1 and F2) in an artificial canal at room temperature (20°C) and at intracanal temperature (35°C). The number of cycles to failure and the fracture length of the fragment were recorded, and data were subjected to statistical analysis. PTG registered no differences in fatigue life between the 2 temperatures tested (P > .05), whereas PTU showed a statistically significant reduction in fatigue life at intracanal temperature compared with room temperature (P  .05). Intracanal temperature influenced the cyclic fatigue resistance of instruments produced with traditional nickel-titanium, whereas it did not influence the fatigue life of instruments produced with gold heat treatment. Gold heating treatment enhances the resistance to cyclic fatigue of ProTaper instruments. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  20. Optical fiber sensors fabricated by the focused ion beam technique

    DEFF Research Database (Denmark)

    Yuan, Scott Wu; Wang, Fei; Bang, Ole

    2012-01-01

    crystal fiber (PCF). Using this technique we fabricate a highly compact fiber-optic Fabry-Pérot (FP) refractive index sensor near the tip of fiber taper, and a highly sensitive in-line temperature sensor in PCF. We also demonstrate the potential of using FIB to selectively fill functional fluid......Focused ion beam (FIB) is a highly versatile technique which helps to enable next generation of lab-on-fiber sensor technologies. In this paper, we demonstrate the use application of FIB to precisely mill the fiber taper and end facet of both conventional single mode fiber (SMF) and photonic...

  1. The Effect of Vibration Characteristics on the Atomization Rate in a Micro-Tapered Aperture Atomizer

    OpenAIRE

    Qiufeng Yan; Jianhui Zhang; Jun Huang; Ying Wang

    2018-01-01

    Because little is known about the atomization theory of a micro-tapered aperture atomizer, we investigated the vibration characteristics of this type of atomizer. The atomization mechanism of a micro-tapered aperture atomizer was described, and the atomization rate equation was deduced. As observed via microscopy, the angle of the micro-tapered aperture changes with the applied voltage, which proved the existence of a dynamic cone angle. The forward and reverse atomization rates were measured...

  2. Dwarf mistletoe does not increase trunk taper in released red firs in California

    Science.gov (United States)

    Robert F. Scharpf

    1977-01-01

    Dwarf mistletoe had no noticeable effect on trunk taper of young, dominant and codominant red firs 4 to 22 inches (10.2 to 55.9 cm) d.b.h. Also, taper was not influenced by live crown ratio of infected and uninfected trees. Trees less than 7 inches d.b.h. had significantly more taper than larger trees, irrespective of dwarf mistletoe.

  3. Ultra-low loss nano-taper coupler for Silicon-on-Insulator ridge waveguide

    DEFF Research Database (Denmark)

    Pu, Minhao; Liu, Liu; Ou, Haiyan

    2010-01-01

    A nano-taper coupler is optimized specially for the transverse-magnetic mode for interfacing light between a silicon-on-insulator ridge waveguide and a single-mode fiber. An ultra-low coupling loss of ~0.36dB is achieved for the nano-taper coupler.......A nano-taper coupler is optimized specially for the transverse-magnetic mode for interfacing light between a silicon-on-insulator ridge waveguide and a single-mode fiber. An ultra-low coupling loss of ~0.36dB is achieved for the nano-taper coupler....

  4. Adiabatic tapered optical fiber fabrication for exciting whispering gallery modes in microcavities

    Science.gov (United States)

    Chenari, Z.; Latifi, H.; Hashemi, R. S.; Doroudmand, F.

    2014-05-01

    This article demonstrates an investigation and analysis of a tapered fiber fabrication using an etchant droplet method. To achieve precise control on process, a two-step etching method is proposed (using 48% concentration of HF acid and Buffered HF) which results in low-loss adiabatic tapered fiber. A spectrum analysis monitoring in addition to a microscopy system was used to verify the etching progress. Tapers with losses less than 0.4 dB in air and 4.5 dB in water are demonstrated. A biconical fiber taper fabricated using this method was used to excite the WGMs on a microsphere surface in aquatic environment.

  5. Effects of type of tapering on anaerobic capacity in young basketball players

    Directory of Open Access Journals (Sweden)

    Hugo Augusto Alvares da Silva Lira

    2017-11-01

    Full Text Available The aim of this study was to analyze the effect of the type of tapering on anaerobic capacity in male young basketball players. This was an experimental research with 12 weeks, developed with 47 basketball players, randomly divided into three groups: linear tapering (LG, tapering by step (SG and control group (CG. All groups participated of the same planning training until the last three weeks of periodization (the tapering phase. Only the CG did not perform tapering. Anaerobic Running Speed Test was carried in the last week of each mesocycle to assess the anaerobic capacity. The findings revealed that anaerobic capacity attenuated from the competitive to tapering phase in LG (p= .01 and SG (p= .01, which was not verified for the CG (p= .29. Significant difference of anaerobic capacity was found between LG and CG (p= .01, SG and CG (p= .01 and between LG and SG (p= .04 in the tapering phase. It was concluded that the tapering strategies were efficient to maximize anaerobic capacity in young basketball players, although linear tapering strategy has been revealed the best strategy for improvement the anaerobic capacity.

  6. Effect of tapering on anaerobic power and capacity of tae-kwon-do athletes

    Directory of Open Access Journals (Sweden)

    Leonardo de Sousa Fortes

    2017-05-01

    Full Text Available DOI: http://dx.doi.org/10.5007/1980-0037.2017v19n2p224   The aim of the study was to analyze the effect of a tapering period on anaerobic power and capacity of tae-kwon-do athletes. Thirty-one male tae-kwon-do participants of the Brazilian Championship were selected in a non-probabilistic way. Subjects were randomly divided into two groups, namely: experimental group (EG, n = 15 and control group (CG, n = 17. Both groups followed the same training protocol up to the tapering stage. CG was submitted to training loads contained in the last two weeks of the macrocycle. Only EG was submitted to tapering. Tapering had 2 weeks duration, adopting the linear tapering method. Taekwondo Anaerobic Test was performed by athletes before the start of the season, which was named as pre-intervention, and the last week of each mesocycle [Prep I, Prep II and Tapering (only EG]. Group vs. time effect interaction (p < 0.01 was identified for alactic anaerobic power, with an increase only in EG in tapering (p = 0.01. A significant group vs. time interaction (p <0.01 was revealed to fatigue index, improved anaerobic capacity being checked in EG only after the tapering period (p = 0.01. It was concluded that two weeks of linear type tapering optimized the anaerobic power and capacity of male tae-kwon-do athletes.

  7. {open_quotes}Optical guiding{close_quotes} limits on extraction efficiencies of single-pass, tapered wiggler amplifiers

    Energy Technology Data Exchange (ETDEWEB)

    Fawley, W.M. [Lawrence Berkeley Lab., CA (United States)

    1995-12-31

    Single-pass, tapered wiggler amplifiers have an attractive feature of being able, in theory at least, of extracting a large portion of the electron beam energy into light. In circumstances where an optical FEL`s wiggler length is significantly longer than the Rayleigh length Z{sub R} corresponding to the electron beam radius, diffraction losses must be controlled via the phenomenon of {open_quotes}optical guiding{close_quotes}. Since the strength of the guiding depends upon the effective refractive index {eta}{sub r} exceeding one, and since ({eta}{sub r}-1) is inversely proportional to the optical electric field, there is a natural {open_quotes}limiting{close_quotes} mechanism to the on-axis field strength and thus the rate at which energy may be extracted from the electron beam. In particular, the extraction efficiency for a prebunched beam asymptotically grows linearly with z rather than quadratically. We present analytical and numerical simulation results concerning this behavior and discuss its applicability to various FEL designs including oscillator/amplifier-radiator configurations.

  8. Modular Fluted Tapered Stems in Aseptic Revision Total Hip Arthroplasty.

    Science.gov (United States)

    Abdel, Matthew P; Cottino, Umberto; Larson, Dirk R; Hanssen, Arlen D; Lewallen, David G; Berry, Daniel J

    2017-05-17

    Modular fluted tapered stems have become the most commonly employed category of femoral component in revision hip arthroplasty in North America as a result of favorable early results and simplicity of use. Despite wide adoption, the majority of published data are limited to relatively small series with modest follow-up. The goal of the current study was to determine the success rate and factors associated with success, failure, and complications of the use of modular fluted tapered stems in aseptic revision total hip arthroplasties (THAs) in a large patient cohort. We identified 519 aseptic femoral revisions during which a modular fluted tapered stem was utilized. Clinical outcomes, Kaplan-Meier survivorship, radiographic outcomes, and complications were assessed. The mean age at revision arthroplasty was 70 years, the mean body mass index (BMI) was 29 kg/m, and the mean duration of follow-up was 4.5 years (range, 2 to 14 years). The mean Harris hip score (HHS) improved significantly from 51 points preoperatively to 76 points at 2 years (p revisions had been performed: 6 because of aseptic loosening, 4 because of infection, 3 because of instability, 2 because of periprosthetic fracture, and 1 because of stem fracture. The 10-year survivorship was 96% with revision for any reason as the end point and 90% with any reoperation as the end point. Of the patients who were alive and had not undergone revision at the time of final follow-up, 12 had stem subsidence but all but 1 of these stems had stabilized after subsiding. Postoperative complications were noted in 12% of the cases. Repeat revision due to femoral component loosening was not correlated with the preoperative bone-loss category or patient demographic factors. In this large series, femoral revision with a modular fluted tapered stem provided a high rate of osseointegration and sustained improvement in clinical scores at the time of the last follow-up. There was also a high rate of successful implant fixation

  9. Helical light emission from plasmonic vortices via magnetic tapered tip

    Science.gov (United States)

    Maccaferri, N.; Gorodetski, Y.; Garoli, D.

    2018-01-01

    We investigate an architecture where a plasmonic vortex excited in a gold surface propagates on an adiabatically tapered magnetic tip and detaches to the far-field while carrying a well-defined optical angular momentum. We analyze the out-coming light and show that, despite generally high losses of flat magnetic surface, our 3D structure exhibits high energy throughput. Moreover, we show that once a magneto-optical activity is activated inside the magnetic tip a modulation of the total power transmittance is possible.

  10. Does Surface Topography Play a Role in Taper Damage in Head-neck Modular Junctions?

    Science.gov (United States)

    Pourzal, Robin; Hall, Deborah J; Ha, Nguyen Q; Urban, Robert M; Levine, Brett R; Jacobs, Joshua J; Lundberg, Hannah J

    2016-10-01

    There are increasing reports of total hip arthroplasty failure subsequent to modular taper junction corrosion. The surfaces of tapers are machined to have circumferential machining marks, resulting in a surface topography of alternating peaks and valleys on the scale of micrometers. It is unclear if the geometry of this machined surface topography influences the degree of fretting and corrosion damage present on modular taper junctions or if there are differences between modular taper junction material couples. (1) What are the differences in damage score and surface topography between CoCr/CoCr and CoCr/Ti modular junctions? (2) How are initial surface topography, flexural rigidity, taper angle mismatch, and time in situ related to visual taper damage scores for CoCr/CoCr couples? (3) How are initial surface topography, flexural rigidity, taper angle mismatch, and time in situ related to visual taper damage scores for CoCr/Ti couples? Damage on stem and head tapers was evaluated with a modified Goldberg score. Differences in damage scores were determined between a group of 140 CoCr/CoCr couples and 129 CoCr/Ti couples using a chi-square test. For a subgroup of 70 retrievals, selected at random, we measured five variables, including initial stem taper machining mark height and spacing, initial head taper roughness, flexural rigidity, and taper angle mismatch. All retrievals were obtained at revision surgeries. None were retrieved as a result of metal-on-metal failures or were recalled implants. Components were chosen so there was a comparable number of each material couple and damage score. Machining marks around the circumference of the tapers were measured using white light interferometry to characterize the initial stem taper surface topography in terms of the height of and spacing between machining mark peaks as well as initial head taper roughness. The taper angle mismatch was assessed with a coordinate measuring machine. Flexural rigidity was determined based

  11. The taper of cast post preparation measured using innovative image processing technique

    Directory of Open Access Journals (Sweden)

    Al Hyiasat Ahmad S

    2010-08-01

    Full Text Available Abstract Background No documentation in the literature about taper of cast posts. This study was conducted to measure the degree of cast posts taper, and to evaluate its suitability based on the anatomy aspects of the common candidate teeth for post reconstruction. Methods Working casts for cast posts, prepared using Gates Glidden drills, were collected. Impressions of post spaces were made using polyvinyl siloxan putty/wash technique. Digital camera with a 10' high quality lens was used for capturing two digital images for each impression; one in the Facio-Lingual (FL and the other in the Mesio-Distal (MD directions. Automated image processing program was developed to measure the degree of canal taper. Data were analyzed using Statistical Package for Social Sciences software and One way Analysis of Variance. Results Eighty four dies for cast posts were collected: 16 for each maxillary anterior teeth subgroup, and 18 for each maxillary and mandibular premolar subgroup. Mean of total taper for all preparations was 10.7 degree. There were no statistical differences among the total taper of all groups (P = .256 or between the MD and FL taper for each subgroup. Mean FL taper for the maxillary first premolars was lower significantly (P = .003 than the maxillary FL taper of the second premolars. FL taper was higher than the MD taper in all teeth except the maxillary first premolars. Conclusions Taper produced did not reflect the differences among the anatomy of teeth. While this technique deemed satisfactory in the maxillary anterior teeth, the same could not be said for the maxillary first premolars. Careful attention to the root anatomy is mandatory.

  12. Extending the photon energy coverage of an x-ray self-seeding FEL via the reverse taper enhanced harmonic generation technique

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Kaiqing; Qi, Zheng [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Feng, Chao, E-mail: fengchao@sinap.ac.cn [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Deng, Haixiao [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Wang, Dong, E-mail: wangdong@sinap.ac.cn [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Zhao, Zhentang [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); University of Chinese Academy of Sciences, Beijing 100049 (China)

    2017-05-11

    In this paper, a simple method is proposed to extend the photon energy range of a soft x-ray self-seeding free-electron laser (FEL). A normal monochromator is first applied to purify the FEL spectrum and provide a coherent seeding signal. This coherent signal then interacts with the electron beam in the following reverse tapered undulator section to generate strong coherent microbunchings while maintain the good quality of the electron beam. After that, the pre-bunched electron beam is sent into the third undulator section which resonates at a target high harmonic of the seed to amplify the coherent radiation at shorter wavelength. Three dimensional simulations have been performed and the results demonstrate that the photon energy gap between 1.5 keV and 4.5 keV of the self-seeding scheme can be fully covered and 100 GW-level peak power can be achieved by using the proposed technique.

  13. Ultra-abrupt tapered fiber Mach-Zehnder interferometer sensors.

    Science.gov (United States)

    Li, Benye; Jiang, Lan; Wang, Sumei; Zhou, Lanying; Xiao, Hai; Tsai, Hai-Lung

    2011-01-01

    A fiber inline Mach-Zehnder interferometer (MZI) consisting of ultra-abrupt fiber tapers was fabricated through a new fusion-splicing method. By fusion-splicing, the taper diameter-length ratio is around 1:1, which is much greater than those (1:10) made by stretching. The proposed fabrication method is very low cost, 1/20-1/50 of those of LPFG pair MZI sensors. The fabricated MZIs are applied to measure refractive index, temperature and rotation angle changes. The temperature sensitivity of the MZI at a length of 30 mm is 0.061 nm/°C from 30-350 °C. The proposed MZI is also used to measure rotation angles ranging from 0° to 0.55°; the sensitivity is 54.98 nm/°. The refractive index sensitivity is improved by 3-5 fold by fabricating an inline micro-trench on the fiber cladding using a femtosecond laser. Acetone vapor of 50 ppm in N(2) is tested by the MZI sensor coated with MFI-type zeolite thin film. The proposed MZI sensors are capable of in situ detection in many areas of interest such as environmental management, industrial process control, and public health.

  14. Ultra-Abrupt Tapered Fiber Mach-Zehnder Interferometer Sensors

    Directory of Open Access Journals (Sweden)

    Lanying Zhou

    2011-05-01

    Full Text Available A fiber inline Mach-Zehnder interferometer (MZI consisting of ultra-abrupt fiber tapers was fabricated through a new fusion-splicing method. By fusion-splicing, the taper diameter-length ratio is around 1:1, which is much greater than those (1:10 made by stretching. The proposed fabrication method is very low cost, 1/20–1/50 of those of LPFG pair MZI sensors. The fabricated MZIs are applied to measure refractive index, temperature and rotation angle changes. The temperature sensitivity of the MZI at a length of 30 mm is 0.061 nm/°C from 30–350 °C. The proposed MZI is also used to measure rotation angles ranging from 0° to 0.55°; the sensitivity is 54.98 nm/°. The refractive index sensitivity is improved by 3–5 fold by fabricating an inline micro–trench on the fiber cladding using a femtosecond laser. Acetone vapor of 50 ppm in N2 is tested by the MZI sensor coated with MFI–type zeolite thin film. The proposed MZI sensors are capable of in situ detection in many areas of interest such as environmental management, industrial process control, and public health.

  15. Moment method analysis of linearly tapered slot antennas

    Science.gov (United States)

    Koeksal, Adnan

    1993-01-01

    A method of moments (MOM) model for the analysis of the Linearly Tapered Slot Antenna (LTSA) is developed and implemented. The model employs an unequal size rectangular sectioning for conducting parts of the antenna. Piecewise sinusoidal basis functions are used for the expansion of conductor current. The effect of the dielectric is incorporated in the model by using equivalent volume polarization current density and solving the equivalent problem in free-space. The feed section of the antenna including the microstripline is handled rigorously in the MOM model by including slotline short circuit and microstripline currents among the unknowns. Comparison with measurements is made to demonstrate the validity of the model for both the air case and the dielectric case. Validity of the model is also verified by extending the model to handle the analysis of the skew-plate antenna and comparing the results to those of a skew-segmentation modeling results of the same structure and to available data in the literature. Variation of the radiation pattern for the air LTSA with length, height, and taper angle is investigated, and the results are tabulated. Numerical results for the effect of the dielectric thickness and permittivity are presented.

  16. Strain-induced bi-thermoelectricity in tapered carbon nanotubes

    Science.gov (United States)

    Algharagholy, L. A. A.; Pope, T.; Lambert, C. J.

    2018-03-01

    We show that carbon-based nanostructured materials are a novel testbed for controlling thermoelectricity and have the potential to underpin the development of new cost-effective environmentally-friendly thermoelectric materials. In single-molecule junctions, it is known that transport resonances associated with the discrete molecular levels play a key role in the thermoelectric performance, but such resonances have not been exploited in carbon nanotubes (CNTs). Here we study junctions formed from tapered CNTs and demonstrate that such structures possess transport resonances near the Fermi level, whose energetic location can be varied by applying strain, resulting in an ability to tune the sign of their Seebeck coefficient. These results reveal that tapered CNTs form a new class of bi-thermoelectric materials, exhibiting both positive and negative thermopower. This ability to change the sign of the Seebeck coefficient allows the thermovoltage in carbon-based thermoelectric devices to be boosted by placing CNTs with alternating-sign Seebeck coefficients in tandem.

  17. Fatigue Life Methodology for Tapered Hybrid Composite Flexbeams

    Science.gov (United States)

    urri, Gretchen B.; Schaff, Jeffery R.

    2006-01-01

    Nonlinear-tapered flexbeam specimens from a full-size composite helicopter rotor hub flexbeam were tested under combined constant axial tension and cyclic bending loads. Two different graphite/glass hybrid configurations tested under cyclic loading failed by delamination in the tapered region. A 2-D finite element model was developed which closely approximated the flexbeam geometry, boundary conditions, and loading. The analysis results from two geometrically nonlinear finite element codes, ANSYS and ABAQUS, are presented and compared. Strain energy release rates (G) associated with simulated delamination growth in the flexbeams are presented from both codes. These results compare well with each other and suggest that the initial delamination growth from the tip of the ply-drop toward the thick region of the flexbeam is strongly mode II. The peak calculated G values were used with material characterization data to calculate fatigue life curves for comparison with test data. A curve relating maximum surface strain to number of loading cycles at delamination onset compared well with the test results.

  18. Fatigue Life Analysis of Tapered Hybrid Composite Flexbeams

    Science.gov (United States)

    Murri, Gretchen B.; Schaff, Jeffery R.; Dobyns, Alan L.

    2002-01-01

    Nonlinear-tapered flexbeam laminates from a full-size composite helicopter rotor hub flexbeam were tested under combined constant axial tension and cyclic bending loads. The two different graphite/glass hybrid configurations tested under cyclic loading failed by delamination in the tapered region. A 2-D finite element model was developed which closely approximated the flexbeam geometry, boundary conditions, and loading. The analysis results from two geometrically nonlinear finite element codes, ANSYS and ABAQUS, are presented and compared. Strain energy release rates (G) obtained from the above codes using the virtual crack closure technique (VCCT) at a resin crack location in the flexbeams are presented for both hybrid material types. These results compare well with each other and suggest that the initial delamination growth from the resin crack toward the thick region of the flexbeam is strongly mode II. The peak calculated G values were used with material characterization data to calculate fatigue life curves and compared with test data. A curve relating maximum surface strain to number of loading cycles at delamination onset compared reasonably well with the test results.

  19. Two-Element Tapered Slot Antenna Array for Terahertz Resonant Tunneling Diode Oscillators

    Directory of Open Access Journals (Sweden)

    Jianxiong Li

    2014-01-01

    Full Text Available Two-element tapered slot antenna (TSA array for terahertz (THz resonant tunneling diode (RTD oscillators is proposed in this paper. The proposed TSA array has the advantages of both the high directivity and high gain at the horizontal direction and hence can facilitate the horizontal communication between the RTD oscillators and other integrated circuit chips. A MIM (metal-insulator-metal stub with a T-shaped slot is used to reduce the mutual coupling between the TSA elements. The validity and feasibility of the proposed TSA array have been simulated and analyzed by the ANSYS/ANSOFT’s High Frequency Structure Simulator (HFSS. Detailed modeling approaches and theoretical analysis of the proposed TSA array have been fully addressed. The simulation results show that the mutual coupling between the TSA elements is reduced below −40 dB. Furthermore, at 500 GHz, the directivity, the gain, and the half power beam width (HPBW at the E-plane of the proposed TSA array are 12.18 dB, 13.09 dB, and 61°, respectively. The proposed analytical method and achieved performance are very promising for the antenna array integrated with the RTD oscillators at the THz frequency and could pave the way to the design of the THz antenna array for the RTD oscillators.

  20. A High-Efficiency Photonic Nanowire Single-Photon Source Featuring An Inverted Conical Taper

    DEFF Research Database (Denmark)

    Gregersen, Niels; Nielsen, Torben Roland; Mørk, Jesper

    2011-01-01

    A photonic nanowire single-photon source design incorporating an inverted conical tapering is proposed. The inverted taper allows for easy electrical contacting and a high photon extraction efficiency of 89 %. Unlike cavity-based approaches, the photonic nanowire features broadband spontaneous...... emission control and an improved tolerance towards fabrication imperfections....

  1. Optimized Stage Ratio of Tapered CMOS Inverters for Minimum Power and Mismatch Jitter Product

    NARCIS (Netherlands)

    Dutta, R.; Bhattacharyya, T.K.; Gao, X.; Klumperink, Eric A.M.

    2010-01-01

    In this paper, an optimum stage ratio (tapering factor) for a tapered CMOS inverter chain is derived to minimize the product of power dissipation and jitter variance due to device mismatch. Analysis shows that this optimum stage ratio (2.4) is lower than that of minimum delay (3.6) and minimum

  2. Compatible taper and volume equations for young longleaf pine plantations in southwest Georgia

    Science.gov (United States)

    Lichun Jiang; John R. Brooks; Alexander Clark

    2010-01-01

    Inside and outside bark taper equations as well as compatible cubic foot volume equations were developed from felled tree data selected from young longleaf pine plantations that are part of an existing growth and yield study located in the Flint River drainage of southwest Georgia. A Max-Burkhart taper model was selected as the basic model form due to the accuracy...

  3. Low insertion loss SOI microring resonator integrated with nano-taper couplers

    DEFF Research Database (Denmark)

    Pu, Minhao; Frandsen, Lars Hagedorn; Ou, Haiyan

    2009-01-01

    We demonstrate a microring resonator working at TM mode integrated with nano-taper couplers with 3.6dB total insertion loss. The measured insertion loss of the nano-taper coupler was only 1.3dB for TM mode....

  4. A Compatible Stem Taper-Volume-Weight System For Intensively Managed Fast Growing Loblolly Pine

    Science.gov (United States)

    Yugia Zhang; Bruce E. Borders; Robert L Bailey

    2002-01-01

    eometry-oriented methodology yielded a compatible taper-volume-weight system of models whose parameters were estimated using data from intensively managed loblolly pine (Pinus taeda L.) plantations in the lower coastal plain of Georgia. Data analysis showed that fertilization has significantly reduced taper (inside and outside bark) on the upper...

  5. In situ compression study of taper-free metallic glass nanopillars

    NARCIS (Netherlands)

    Kuzmin, O.V.; Pei, Y.T.; Hosson, J.T.M. De

    2011-01-01

    Because tapering leads to inevitable artifacts in the analyses of compression experiments on micrometer sized pillars, in this study taper-free nanosized pillars of Zr-based metallic glass of Zr61.8Cu18Ni10.2Al10 composition with diameter ranging from 600 to 90 nm were fabricated. These pillars were

  6. Development of a tapered cell drift chamber II: operation in high magnetic fields and different gas pressures

    International Nuclear Information System (INIS)

    Blissett, J.A.; Hasell, D.K.; Parham, A.G.; Payne, B.T.; Saxon, D.H.

    1985-11-01

    Several designs for drift cells have been constructed and tested in an electron beam at DESY. The designs tested consisted of pairs of adjacent tapered cells, of eight sense wires each, to simulate a portion of a layer of drift cells in a central tracking detector. Tests were made to study the operation and resolution of the drift cells under a variety of conditions. Ar:C 2 H 6 (50:50) and Ar:CO 2 :CH 4 (90:9:1) gas mixtures were used at absolute pressures of one to four bar for the former and at one bar for the latter. Measurements were made at different electric drift fields in conjunction with magnetic fields varying from 0 to 1.82 T. Aspects of the construction, electronics and operation are discussed and results regarding the resolution as a function of drift distance and operating conditions are presented with some model calculations. (author)

  7. Dual-wavelength high-power diode laser system based on an external-cavity tapered amplifier with tunable frequency difference

    DEFF Research Database (Denmark)

    Chi, Mingjun; Jensen, Ole Bjarlin; Petersen, Paul Michael

    2012-01-01

    knowledge, this is the broadest tuning range of the frequency difference from a dual-wavelength diode laser system. The spectrum, output power, and beam quality of the diode laser system are characterized. The power stability of each wavelength is measured, and the power fluctuations of the two wavelengths......A dual-wavelength high-power semiconductor laser system based on a tapered amplifier with double-Littrow external cavity is demonstrated around 800 nm. The two wavelengths can be tuned individually, and the frequency difference of the two wavelengths is tunable from 0.5 to 10.0 THz. To our...

  8. Asymmetric Draw-Tower Tapers for Supercontinuum Generation and Verification of the Novel Concept of Group-Acceleration Matching

    DEFF Research Database (Denmark)

    Sørensen, Simon Toft; Møller, Uffe; Moselund, P. M.

    2012-01-01

    We present the first short asymmetrical draw-tower photonic crystal fiber taper for maximizing the power in the blue edge of a supercontinuum. The results clearly emphasize the importance of the taper shape on the spectrum....

  9. Dentinal crack formation during root canal preparations by the twisted file adaptive, ProTaper Next, ProTaper Universal, and WaveOne instruments.

    Science.gov (United States)

    Karataş, Ertuğrul; Gündüz, Hicran Ateş; Kırıcı, Damla Özsu; Arslan, Hakan; Topçu, Meltem Çolak; Yeter, Kübra Yeşildal

    2015-02-01

    The aim of this study was to compare the incidence of root cracks after root canal instrumentation with the TF Adaptive, WaveOne, ProTaper Next, and ProTaper Universal systems. Seventy-five extracted mandibular central incisors with mature apices and straight root canals (magnification. The samples were photographed with a camera to determine the presence of dentinal cracks. The control group had no cracks, and the difference between the control group and the experimental groups was statistically significant (P < .001). The ProTaper Next and TF Adaptive systems produced significantly less cracks than the ProTaper Universal and WaveOne systems in the apical section (3 mm) (P < .05). Under the study conditions and within the limitations of this study, it can be concluded that the ProTaper Universal, ProTaper Next, WaveOne, and TF Adaptive instruments can result in dentinal cracks. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  10. Comparison of debris extruded apically and working time used by ProTaper Universal rotary and ProTaper retreatment system during gutta-percha removal

    Science.gov (United States)

    UEZU, Mary Kinue Nakamune; BRITTO, Maria Leticia Borges; NABESHIMA, Cleber K.; PALLOTTA, Raul Capp

    2010-01-01

    Objective The aim of this study was to evaluate the in vitro action of ProTaper retreatment files and ProTaper Universal in the retreatment of mandibular premolars. Material and methods The amount of debris extruded apically was measured and the time to reach the working length and to complete the removal of gutta-percha was observed. Thirty teeth had their canals prepared using ProTaper Universal files and were obturated by the single cone technique. The teeth were then stored at 37ºC in a humid environment for 7 days. During the use of the rotary instruments for root canal filling removal, the apical portions of the teeth were attached to the open end of a resin tube to collect the apically extruded debris. Results ProTaper Universal files were significantly faster (p=0.0011) than the ProTaper retreatment files to perform gutta-percha removal, but no significant difference was found between the files regarding the time to reach the working length or the amount of apical extrusion. Conclusions ProTaper Universal rotary had better results for endodontic retreatment, and both techniques promote similar apical extrusion of debris. PMID:21308282

  11. Comparison of debris extruded apically and working time used by ProTaper Universal rotary and ProTaper retreatment system during gutta-percha removal

    Directory of Open Access Journals (Sweden)

    Mary Kinue Nakamune Uezu

    2010-12-01

    Full Text Available OBJECTIVE: The aim of this study was to evaluate the in vitro action of ProTaper retreatment files and ProTaper Universal in the retreatment of mandibular premolars. MATERIAL AND METHODS: The amount of debris extruded apically was measured and the time to reach the working length and to complete the removal of gutta-percha was observed. Thirty teeth had their canals prepared using ProTaper Universal files and were obturated by the single cone technique. The teeth were then stored at 37ºC in a humid environment for 7 days. During the use of the rotary instruments for root canal filling removal, the apical portions of the teeth were attached to the open end of a resin tube to collect the apically extruded debris. RESULTS: ProTaper Universal files were significantly faster (p=0.0011 than the ProTaper retreatment files to perform gutta-percha removal, but no significant difference was found between the files regarding the time to reach the working length or the amount of apical extrusion. CONCLUSIONS: ProTaper Universal rotary had better results for endodontic retreatment, and both techniques promote similar apical extrusion of debris.

  12. Quantitative evaluation of apically extruded debris during root canal instrumentation with ProTaper Universal, ProTaper Next, WaveOne, and self-adjusting file systems

    Science.gov (United States)

    Ozsu, Damla; Karatas, Ertugrul; Arslan, Hakan; Topcu, Meltem C.

    2014-01-01

    Objectives: The aim of this study was to compare the amount of apically extruded debris during preparation with ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland), ProTaper Next (Dentsply Maillefer), a reciprocating single-file (WaveOne; VDW GmbH, Munich, Germany), and a self-adjusting file (SAF; ReDent Nova, Ra’anna, Israel). Materials and Methods: Fifty-six intact mandibular premolar teeth were randomly assigned to four groups. The root canals were prepared according to the manufacturers’ instructions using the ProTaper Universal, ProTaper Next, WaveOne, and SAF. Apically extruded debris was collected in preweighted Eppendorf tubes during instrumentation. The net weight of the apically extruded debris was determined by subtracting the preweights and postweights of the tubes. The data were statistically analyzed using the one-way analysis of variance and the least significant difference tests at a significance level of P < 0.05. Results: A measurable amount of debris was apically extruded in all groups, and the amounts of debris extrusion in the groups were statistically significant (P < 0.001). The ProTaper Next and WaveOne groups resulted in less debris extrusion than the ProTaper Universal group (P < 0.05), and the SAF group resulted in the least debris extrusion. Conclusions: Within the limitations of the present study, it can be concluded that all systems extruded debris beyond the apical foramen. PMID:25512732

  13. An in vitro comparison of apically extruded debris and instrumentation times with ProTaper Universal, ProTaper Next, Twisted File Adaptive, and HyFlex instruments.

    Science.gov (United States)

    Capar, Ismail Davut; Arslan, Hakan; Akcay, Merve; Ertas, Huseyin

    2014-10-01

    The purpose of this study was to compare the in vitro amount of apically extruded debris with new endodontic rotary nickel-titanium instruments. Sixty mandibular premolars were instrumented up to size 25 using ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland), ProTaper Next (Dentsply Maillefer), Twisted File Adaptive (SybronEndo, Orange, CA), and HyFlex (Coltene-Whaledent, Allstetten, Switzerland) rotary systems. The apically extruded debris was collected and dried in preweighed Eppendorf tubes. The amount of extruded debris was assessed with an electronic balance. The total time required to complete root canal shaping with the different instruments was also recorded. The significance level was set at P = .05. The instrumentation time with the ProTaper Universal rotary system was significantly longer than with all the other instruments (P extruded significantly less debris than the ProTaper Universal and HyFlex systems (P < .05). The ProTaper Next and Twisted File Adaptive instrumentation systems were associated with less debris extrusion compared with the ProTaper Universal and HyFlex systems. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  14. Optimization of the soliton self-frequency shift in a tapered photonic crystal fiber

    DEFF Research Database (Denmark)

    Judge, A.C.; Bang, Ole; Eggleton, B.J.

    2009-01-01

    Soliton propagation is modeled in a tapered photonic crystal fiber for various taper profiles with the purpose of optimizing the soliton self-frequency shift (SSFS) in such geometries. An optimal degree of tapering is found to exist for tapers with an axially uniform waist. In the case of axially...... nonuniform waists, an additional enhancement of the SSFS is achieved by varying the taper waist diameter along its length in a carefully designed fashion in order to present an optimal level of group-velocity dispersion to the soliton at each point, thus avoiding the spectral recoil due to the emission...... of dispersive waves. In doing so, the increased nonlinearity and dispersion engineering afforded by the reduction of the core size are exploited while circumventing the limitation imposed on the soliton redshift by the associated shortening of the red zero-dispersion wavelength....

  15. Spectral tuning of a locally bent microfiber taper interferometer with a nanosized liquid crystal overlay.

    Science.gov (United States)

    Luo, Haimei; Wang, Changjing; Ji, Yinghua; Yuan, Wen; Zhang, Guoping; Wang, Yifan; Hong, Zehua; Wang, Xianping

    2016-09-10

    In this paper, the tuning characteristics of locally bent microfiber taper covered with a nanosized high-refractive-index liquid crystal (LC) layer under different temperatures and electric field intensities have been theoretically analyzed and experimentally investigated. A locally bent microfiber taper interferometer with a waist diameter of ∼3.72  μm is fabricated by using the flame brushing technique, followed by bending the transition region of the taper to form a modal interferometer and later by placing a ∼200  nm LC layer over the uniform taper waist region. Experimental results indicate that a high-efficiency thermal or electric tuning of an LC-coated locally bent microfiber taper interferometer could be achieved. This suggests a potential application of this device as tunable all-fiber photonic devices, such as filters, modulators, and sensing elements.

  16. Optimum fiber tapers for increasing the power in the blue-edge of a supercontinuum - group-acceleration matching

    DEFF Research Database (Denmark)

    Sørensen, Simon Toft; Judge, Alexander; Thomsen, Carsten L.

    2011-01-01

    We demonstrate how the gradient of the tapering in a tapered fiber can significantly affect the trapping and blueshift of dispersive waves (DWs) by a soliton. By modeling the propagation of a fundamental 10 fs soliton through tapered fibers with varying gradients, it is shown that the soliton tra...

  17. Controlling Force in Polarization-Maintaining Fiber Fused Biconical Tapering

    Directory of Open Access Journals (Sweden)

    Wei Zhang

    2015-01-01

    Full Text Available Fused biconical tapering (FBT is an important method of manufacturing polarization-maintaining fiber (PMF couplers. However, the tension on the ends of the fibers can affect the performance of the coupler. In this paper, a computer-based method of controlling the drawing force was presented. The system includes a drawing mechanism, rotary position encoders, and a control circuit. A three-dimensional model of a permanent magnet and a coil is constructed, and the relationship among the coil current, rotation angle of the clamp, and electromagnetic force is determined using finite element simulations. Electromagnetic force control based on these simulations can be realized. The method is verified experimentally, and it is shown that a drawing force of 0–1.8 gf can be achieved with an error of within 3.04%. This result can be used in the FBT-based manufacture of fiber components such as fiber couplers and gratings.

  18. RF Design of the TW Buncher for the CLIC Drive Beam Injector (2nd report)

    CERN Document Server

    Shaker, Hamed

    2016-01-01

    CLIC is based on the two beams concept that one beam (drive beam) produces the required RF power to accelerate another beam (main beam). The drive beam is produced and accelerated up to 50MeV inside the CLIC drive beam injector. The drive beam injector main components are a thermionic electron gun, three sub-harmonic bunchers, a pre-buncher, a TW buncher, 13 accelerating structures and one magnetic chicane. This document is the second report of the RF structure design of the TW buncher. This design is based on the beam dynamic design done by Shahin Sanaye Hajari due to requirements mentioned in CLIC CDR. A disk-loaded tapered structure is chosen for the TW buncher. The axial electric field increases strongly based on the beam dynamic requirements. This second report includes the study of HOM effects, retuning the cells, study of dimensional tolerances and the heat dissipation on the surface.

  19. Vibration of nonuniform carbon nanotube with attached mass via nonlocal Timoshenko beam theory

    International Nuclear Information System (INIS)

    Tang, Hai Li; Shen, Zhi Bin; Li, Dao Kui

    2014-01-01

    This paper studies the vibrational behavior of nonuniform single-walled carbon nanotube (SWCNT) carrying a nanoparticle. A nonuniform cantilever beam with a concentrated mass at the free end is analyzed according to the nonlocal Timoshenko beam theory. A governing equation of a nonuniform SWCNT with attached mass is established. The transfer function method incorporating with the perturbation method is utilized to obtain the resonant frequencies of a vibrating nonlocal cantilever-mass system. The effects of the nonlocal parameter, taper ratio and attached mass on the natural frequencies and frequency shifts are discussed. Obtained results indicate that the sensitivity of the frequency shifts on the attached mass increases when the length-to-diameter ratio decreases. Tapered SWCNT possesses higher fundamental frequencies if the taper ratio becomes larger.

  20. Stem subsidence of polished and rough double-taper stems

    Science.gov (United States)

    Yamada, Kengo; Hirosaki, Kenichi; Takano, Masahiro; Matsumoto, Tadami

    2009-01-01

    Background and purpose Many clinical reports have indicated that polished hip stems show better clinical results than rough stems of the same geometry. It is still unknown, however, what the mechanical effects are of different surface finishes on the cement at the cement-bone interface. We compared mechanical effects in an in vitro cemented hip arthroplasty model. Methods Two sizes of double-taper polished stems and matt-processed polished stems (rough stems) were fixed into composite femurs. A 1-Hz dynamic load was applied to the stems for 1 million cycles. An 8-h no-load period was set after every 16 h of load. Stem subsidence within the cement, and compressive force and horizontal cement creep at the cement-bone interface, were measured. Results Compared to rough stems, stem subsidence, compressive force and cement creep for polished stems were a maximum of 4, 12, and 7-fold greater, respectively. There was a strong positive correlation between stem subsidence and compressive force for polished stems. In contrast, a strong negative correlation was found between stem subsidence and compressive force for rough stems. There was also a statistically significant relationship between compressive force on the cement and cement creep for the polished stems, but no significant relationship was found for rough stems. Interpretation This is the first evidence that different surface finishes of stems can have different mechanical effects on the cement at the cement-bone interface. Stem subsidence in polished stems resulted in compressive force on the cement and cement creep. The mechanical effects that polished taper stems impart on cement at the cement-bone interface probably contribute to their good long-term fixation and excellent clinical outcome. PMID:19421909

  1. Stem Measurements and Taper Modeling Using Photogrammetric Point Clouds

    Directory of Open Access Journals (Sweden)

    Rong Fang

    2017-07-01

    Full Text Available The estimation of tree biomass and the products that can be obtained from a tree stem have focused forest research for more than two centuries. Traditionally, measurements of the entire tree bole were expensive or inaccurate, even when sophisticated remote sensing techniques were used. We propose a fast and accurate procedure for measuring diameters along the merchantable portion of the stem at any given height. The procedure uses unreferenced photos captured with a consumer grade camera. A photogrammetric point cloud (PPC is produced from the acquired images using structure from motion, which is a computer vision range imaging technique. A set of 18 loblolly pines (Pinus taeda Lindl. from east Louisiana, USA, were photographed, subsequently cut, and the diameter measured every meter. The same diameters were measured on the point cloud with AutoCAD Civil3D. The ground point cloud reconstruction provided useful information for at most 13 m along the stem. The PPC measurements are biased, overestimating real diameters by 17.2 mm, but with a reduced standard deviation (8.2%. A linear equation with parameters of the error at a diameter at breast height (d1.3 and the error of photogrammetric rendering reduced the bias to 1.4 mm. The usability of the PPC measurements in taper modeling was assessed with four models: Max and Burkhart [1], Baldwin and Feduccia [2], Lenhart et al. [3], and Kozak [4]. The evaluation revealed that the data fit well with all the models (R2 ≥ 0.97, with the Kozak and the Baldwin and Feduccia performing the best. The results support the replacement of taper with PPC, as faster, and more accurate and precise product estimations are expected.

  2. Simulating Matrix Crack and Delamination Interaction in a Clamped Tapered Beam

    Science.gov (United States)

    De Carvalho, N. V.; Seshadri, B. R.; Ratcliffe, J. G.; Mabson, G. E.; Deobald, L. R.

    2017-01-01

    Blind predictions were conducted to validate a discrete crack methodology based on the Floating Node Method to simulate matrix-crack/delamination interaction. The main novel aspects of the approach are: (1) the implementation of the floating node method via an 'extended interface element' to represent delaminations, matrix-cracks and their interaction, (2) application of directional cohesive elements to infer overall delamination direction, and (3) use of delamination direction and stress state at the delamination front to determine migration onset. Overall, good agreement was obtained between simulations and experiments. However, the validation exercise revealed the strong dependence of the simulation of matrix-crack/delamination interaction on the strength data (in this case transverse interlaminar strength, YT) used within the cohesive zone approach applied in this work. This strength value, YT, is itself dependent on the test geometry from which the strength measurement is taken. Thus, choosing an appropriate strength value becomes an ad-hoc step. As a consequence, further work is needed to adequately characterize and assess the accuracy and adequacy of cohesive zone approaches to model small crack growth and crack onset. Additionally, often when simulating damage progression with cohesive zone elements, the strength is lowered while keeping the fracture toughness constant to enable the use of coarser meshes. Results from the present study suggest that this approach is not recommended for any problem involving crack initiation, small crack growth or multiple crack interaction.

  3. Treatment with stereotactic radiotherapy body in lung cancer using tomography with taper beam of megavoltage

    International Nuclear Information System (INIS)

    Crispin Contreras, V.; Pastor i Sanchis, V.; Abad Mocholi, D.; Bartres Salido, A.; Mut Dolera, A.; Aznar Santamaria, M.; Dolores Alemany, V. de los; Gonzalez Perez, V.; Guardino de la Flor, C.

    2013-01-01

    Analyzes variations inter and intra fraction and their corrections online, for this case and for the 13 first. We study the dosimetric parameters recommended in the RTOG 0813 Protocol. Reported global dosimetry of treatments; discussed pros and cons of this methodology. (Author)

  4. Endodontic Shaping Performance Using Nickel–Titanium Hand and Motor ProTaper Systems by Novice Dental Students

    Directory of Open Access Journals (Sweden)

    Ming-Gene Tu

    2008-05-01

    Conclusion: These findings show that the novice students prepared the simulated curved canal that deviated more outwardly from apical 1 mm to 4 mm using the hand ProTaper. The ability to maintain the original curvature was better in the motor rotary ProTaper group than in the hand ProTaper group. Undergraduate students, if following the preparation sequence carefully, could successfully perform canal shaping by motor ProTaper files and achieve better root canal geometry than by using hand ProTaper files within the same teaching and practicing sessions.

  5. Modern trunnions are more flexible: a mechanical analysis of THA taper designs.

    Science.gov (United States)

    Porter, David A; Urban, Robert M; Jacobs, Joshua J; Gilbert, Jeremy L; Rodriguez, José A; Cooper, H John

    2014-12-01

    There is renewed concern surrounding the potential for corrosion at the modular head-neck junction to cause early failure in contemporary THAs. Although taper corrosion involves a complex interplay of many factors, a previous study suggested that a decrease in flexural rigidity of the femoral trunnion may be associated with an increased likelihood of corrosion at retrieval. By analyzing a large revision retrieval database of femoral stems released during a span of three decades, we asked: (1) how much does flexural rigidity vary among different taper designs; (2) what is the contribution of taper geometry alone to flexural rigidity of the femoral trunnion; and (3) how have flexural rigidity and taper length changed with time in this group of revised retrievals? A dual-center retrieval analysis of 85 modular femoral stems released between 1983 and 2012 was performed, and the flexural rigidity and length of the femoral trunnions were determined. These stems were implanted between 1991 and 2012 and retrieved at revision or removal surgery between 2004 and 2012. There were 10 different taper designs made from five different metal alloys from 16 manufacturers. Digital calipers were used to measure taper geometries by two independent observers. Median flexural rigidity was 228 N-m(2); however, there was a wide range of values among the various stems spanning nearly an order of magnitude between the most flexible (80 N-m(2)) and most rigid (623 N-m(2)) trunnions, which was partly attributable to the taper geometry and to the material properties of the base alloy. There was a negative correlation between flexural rigidity and length of the trunnion and release date of the stem. There is wide variability in flexural rigidity of various taper designs, with a trend toward trunnions becoming shorter and less rigid with time. This temporal trend may partly explain why taper corrosion is being seen with increasing frequency in modern THAs.

  6. Coherent beam-beam effects

    International Nuclear Information System (INIS)

    Chao, A.W.

    1992-01-01

    There are two physical pictures that describe the beam-beam interaction in a storage ring collider: The weak-strong and the strong-strong pictures. Both pictures play a role in determining the beam-beam behavior. This review addresses only the strong-strong picture. The corresponding beam dynamical effects are referred to as the coherent beam-beam effects. Some basic knowledge of the weak-strong picture is assumed. To be specific, two beams of opposite charges are considered. (orig.)

  7. Extraordinary optical transmission with tapered slits: effect of higher diffraction and slit resonance orders

    DEFF Research Database (Denmark)

    Sondergaard, T.; Bozhevolnyi, S. I.; Beermann, J.

    2012-01-01

    Transmission through thin metal films with a periodic arrangement of tapered slits is considered. Transmission maps covering a wide range of periods, film thicknesses, and taper angles are presented. The maps show resonant transmission when fundamental and higher-order slit resonances are excited....... A study of the effect on transmission of different combinations of available transmission and reflection diffraction orders show optimum total transmission when only the fundamental reflection order and higher transmission diffraction orders are available. The optimum taper angle is shown...

  8. Transmission of fast highly charged ions through straight and tapered glass capillaries

    International Nuclear Information System (INIS)

    Ayyad, Asma M; Keerthisinghe, D; Kayani, A; Tanis, J A; Dassanayake, B S; Ikeda, T

    2013-01-01

    The transmission of 1 and 3 MeV protons through a borosilicate straight glass capillary and a tapered glass capillary was investigated. The straight capillary had a diameter of ∼0.18 mm and a length of ∼14.4 mm, while the tapered capillary had an inlet diameter of ∼0.71 mm, an outlet diameter of ∼0.10 mm and a length of ∼28 mm. The results show that the 1 and 3 MeV protons traverse through both samples without energy loss, while the tapered capillary showed better transmission than the straight capillary. (paper)

  9. Optical microscope and tapered fiber coupling apparatus for a dilution refrigerator.

    Science.gov (United States)

    MacDonald, A J R; Popowich, G G; Hauer, B D; Kim, P H; Fredrick, A; Rojas, X; Doolin, P; Davis, J P

    2015-01-01

    We have developed a system for tapered fiber measurements of optomechanical resonators inside a dilution refrigerator, which is compatible with both on- and off-chip devices. Our apparatus features full three-dimensional control of the taper-resonator coupling conditions enabling critical coupling, with an overall fiber transmission efficiency of up to 70%. Notably, our design incorporates an optical microscope system consisting of a coherent bundle of 37,000 optical fibers for real-time imaging of the experiment at a resolution of ∼1 μm. We present cryogenic optical and optomechanical measurements of resonators coupled to tapered fibers at temperatures as low as 9 mK.

  10. Superresolution beams

    CSIR Research Space (South Africa)

    Ngcobo, S

    2011-11-01

    Full Text Available zones capable of introducing a phase shift of zero or p on the alternately out of phase rings of the TEMp0 beams into a unified phase and then focusing the rectified beam to generate a high resolution beam which has a Gaussian beam intensity distribution...

  11. Suitability of Secondary PEEK Telescopic Crowns on Zirconia Primary Crowns: The Influence of Fabrication Method and Taper

    Directory of Open Access Journals (Sweden)

    Susanne Merk

    2016-11-01

    Full Text Available This study investigates the retention load (RL between ZrO2 primary crowns and secondary polyetheretherketone (PEEK crowns made by different fabrication methods with three different tapers. Standardized primary ZrO2 crowns were fabricated with three different tapers: 0°, 1°, and 2° (n = 10/group. Ten secondary crowns were fabricated (i milled from breCam BioHPP blanks (PM; (ii pressed from industrially fabricated PEEK pellets (PP (BioHPP Pellet; or (iii pressed from granular PEEK (PG (BioHPP Granulat. One calibrated operator adjusted all crowns. In total, the RL of 90 secondary crowns were measured in pull-off tests at 50 mm/min, and each specimen was tested 20 times. Two- and one-way ANOVAs followed by a Scheffé’s post-hoc test were used for data analysis (p < 0.05. Within crowns with a 0° taper, the PP group showed significantly higher retention load values compared with the other groups. Among the 1° taper, the PM group presented significantly lower retention loads than the PP group. However, the pressing type had no impact on the results. Within the 2° taper, the fabrication method had no influence on the RL. Within the PM group, the 2° taper showed significantly higher retention load compared with the 1° taper. The taper with 0° was in the same range value as the 1° and 2° tapers. No impact of the taper on the retention value was observed between the PP groups. Within the PG groups, the 0° taper presented significantly lower RL than the 1° taper, whereas the 2° taper showed no differences. The fabrication method of the secondary PEEK crowns and taper angles showed no consistent effect within all tested groups.

  12. Efficient concept for generation of diffraction-limited green light by sum-frequency generation of spectrally combined tapered diode lasers

    DEFF Research Database (Denmark)

    Müller, André; Jensen, Ole Bjarlin; Hasler, Karl-Heinz

    2012-01-01

    In order to increase the power of visible diode laser systems in an efficient manner, we propose spectral beam combining with subsequent sum-frequency generation. We show that this approach, in comparison with second harmonic generation of single emitters, can enhance the available power signific......In order to increase the power of visible diode laser systems in an efficient manner, we propose spectral beam combining with subsequent sum-frequency generation. We show that this approach, in comparison with second harmonic generation of single emitters, can enhance the available power...... significantly. By combining two distributed Bragg reflector tapered diode lasers we achieve a 2.5–3.2 fold increase in power and a maximum of 3.9 W of diffraction-limited green light. At this power level, green diode laser systems have a high application potential, e.g., within the biomedical field. Our concept...

  13. Design proposal for ultimate shear strength of tapered steel plate girders

    Directory of Open Access Journals (Sweden)

    A. Bedynek

    2017-03-01

    Full Text Available Numerous experimental and numerical studies on prismatic plate girders subjected to shear can be found in the literature. However, the real structures are frequently designed as non-uniform structural elements. The main objective of the research is the development of a new proposal for the calculation of the ultimate shear resistance of tapered steel plate girders taking into account the specific behaviour of such members. A new mechanical model is presented in the paper and it is used to show the differences between the behaviour of uniform and tapered web panels subjected to shear. EN 1993-1-5 design specifications for the determination of the shear strength for rectangular plates are improved in order to assess the shear strength of tapered elements. Numerical studies carried out on tapered steel plate girders subjected to shear lead to confirm the suitability of the mechanical model and the proposed design expression.

  14. Asymmetric first order shear horizontal guided waves propagation in a tapered plate

    International Nuclear Information System (INIS)

    Chen, Jiu-Jiu; Song, Guang-Huang; Han, Xu

    2015-01-01

    In this paper, through numerical simulation of the first order shear horizontal guided waves propagation in a homogeneous tapered plate, we have realized sound unidirectional transmission based on the mode conversion mechanism. We also find that the contrast transmission ratio of unidirectional transmission is highly influenced by the slope angle of tapered edge. And the working frequency range of the asymmetric transmission can be easily controlled by the height of tapered surface or the thickness of slab. This asymmetric system shows potentially significant applications in various sound devices. - Highlights: • We study the sound unidirectional transmission for SH 1 guided wave in a homogeneous tapered plate. • The contrast transmission ratio of unidirectional transmission is highly influenced by the slope angle. • The working frequency range of unidirectional transmission can be easily controlled by structure parameters

  15. Physiological changes associated with the pre-event taper in athletes.

    Science.gov (United States)

    Mujika, Iñigo; Padilla, Sabino; Pyne, David; Busso, Thierry

    2004-01-01

    Some of the physiological changes associated with the taper and their relationship with athletic performance are now known. Since the 1980s a number of studies have examined various physiological responses associated with the cardiorespiratory, metabolic, hormonal, neuromuscular and immunological systems during the pre-event taper across a number of sports. Changes in the cardiorespiratory system may include an increase in maximal oxygen uptake, but this is not a necessary prerequisite for taper-induced gains in performance. Oxygen uptake at a given submaximal exercise intensity can decrease during the taper, but this response is more likely to occur in less-skilled athletes. Resting, maximal and submaximal heart rates do not change, unless athletes show clear signs of overreaching before the taper. Blood pressure, cardiac dimensions and ventilatory function are generally stable, but submaximal ventilation may decrease. Possible haematological changes include increased blood and red cell volume, haemoglobin, haematocrit, reticulocytes and haptoglobin, and decreased red cell distribution width. These changes in the taper suggest a positive balance between haemolysis and erythropoiesis, likely to contribute to performance gains. Metabolic changes during the taper include: a reduced daily energy expenditure; slightly reduced or stable respiratory exchange ratio; increased peak blood lactate concentration; and decreased or unchanged blood lactate at submaximal intensities. Blood ammonia concentrations show inconsistent trends, muscle glycogen concentration increases progressively and calcium retention mechanisms seem to be triggered during the taper. Reduced blood creatine kinase concentrations suggest recovery from training stress and muscle damage, but other biochemical markers of training stress and performance capacity are largely unaffected by the taper. Hormonal markers such as testosterone, cortisol, testosterone : cortisol ratio, 24-hour urinary cortisol

  16. Artificial Intelligence Procedures for Tree Taper Estimation within a Complex Vegetation Mosaic in Brazil.

    Directory of Open Access Journals (Sweden)

    Matheus Henrique Nunes

    Full Text Available Tree stem form in native tropical forests is very irregular, posing a challenge to establishing taper equations that can accurately predict the diameter at any height along the stem and subsequently merchantable volume. Artificial intelligence approaches can be useful techniques in minimizing estimation errors within complex variations of vegetation. We evaluated the performance of Random Forest® regression tree and Artificial Neural Network procedures in modelling stem taper. Diameters and volume outside bark were compared to a traditional taper-based equation across a tropical Brazilian savanna, a seasonal semi-deciduous forest and a rainforest. Neural network models were found to be more accurate than the traditional taper equation. Random forest showed trends in the residuals from the diameter prediction and provided the least precise and accurate estimations for all forest types. This study provides insights into the superiority of a neural network, which provided advantages regarding the handling of local effects.

  17. Ultra-low-loss inverted taper coupler for silicon-on-insulator ridge waveguide

    DEFF Research Database (Denmark)

    Pu, Minhao; Liu, Liu; Ou, Haiyan

    2010-01-01

    An ultra-low-loss coupler for interfacing a silicon-on-insulator ridge waveguide and a single-mode fiber in both polarizations is presented. The inverted taper coupler, embedded in a polymer waveguide, is optimized for both the transverse-magnetic and transverse-electric modes through tapering...... the width of the silicon-on-insulator waveguide from 450 nm down to less than 15 nm applying a thermal oxidation process. Two inverted taper couplers are integrated with a 3-mm long silicon-on-insulator ridge waveguide in the fabricated sample. The measured coupling losses of the inverted taper coupler...... for transverse-magnetic and transverse-electric modes are ~0.36 dB and ~0.66 dB per connection, respectively....

  18. Artificial Intelligence Procedures for Tree Taper Estimation within a Complex Vegetation Mosaic in Brazil.

    Science.gov (United States)

    Nunes, Matheus Henrique; Görgens, Eric Bastos

    2016-01-01

    Tree stem form in native tropical forests is very irregular, posing a challenge to establishing taper equations that can accurately predict the diameter at any height along the stem and subsequently merchantable volume. Artificial intelligence approaches can be useful techniques in minimizing estimation errors within complex variations of vegetation. We evaluated the performance of Random Forest® regression tree and Artificial Neural Network procedures in modelling stem taper. Diameters and volume outside bark were compared to a traditional taper-based equation across a tropical Brazilian savanna, a seasonal semi-deciduous forest and a rainforest. Neural network models were found to be more accurate than the traditional taper equation. Random forest showed trends in the residuals from the diameter prediction and provided the least precise and accurate estimations for all forest types. This study provides insights into the superiority of a neural network, which provided advantages regarding the handling of local effects.

  19. Carotid stenting using tapered and nontapered stents: associated neurological complications and restenosis rates.

    Science.gov (United States)

    Brown, Katherine E; Usman, Asad; Kibbe, Melina R; Morasch, Mark D; Matsumura, Jon S; Pearce, William H; Amaranto, Daniel J; Eskandari, Mark K

    2009-01-01

    Self-expanding stent design systems for carotid artery stenting (CAS) have morphed from nontapered (NTS) to tapered (TS); however, the impact of this change is unknown. We reviewed the outcomes of CAS with these two broad categories of stents in a single-center retrospective review of 308 CAS procedures from May 2001 to July 2007. Nitinol self-expanding TS or NTS coupled with cerebral embolic protection devices were used to treat extracranial carotid occlusive disease. Data analysis included demographics, procedural records, duplex exams, and conventional arteriography. Mean follow-up was 18 months (range 1-69). Restenosis was defined as >or=80% in-stent carotid artery stenosis by angiography. The mean age of the entire cohort was 71.3 years (75% men, 25% women). Of the 308 cases, 233 were de novo lesions and 75 had a prior ipsilateral carotid endarterectomy (n = 44) or external beam radiation exposure (n = 31). Preprocedure neurological symptoms were present in 30% of patients. TS were used in 156 procedures and NTS in 152 procedures. The 30-day ipsilateral stroke and death rates were 1.3% and 0.3%, respectively. An additional three (1.0%) posterior circulation strokes occurred. There was no statistically significant difference in the 30-day total stroke rates between TS (3.2%, n = 5) and NTS (1.3%, n = 2) (p = 0.5). At midterm follow-up, restenosis or asymptomatic occlusion was detected in eight cases (2.6%). All occurred in arteries treated with NTS, and this was statistically different when compared to arteries treated with TS (p = 0.03). Furthermore, a post-hoc subgroup analysis revealed significant correlation (chi(2) = 0.02) for restenosis in "hostile necks" when separated by TS vs. NTS. Early CAS outcomes between TS and NTS are comparable. In contrast, self-expanding nitinol TS may have a lower incidence of significant restenosis or asymptomatic occlusion when compared to NTS.

  20. Large aperture CCD x-ray detector for protein crystallography using a fiberoptic taper

    Energy Technology Data Exchange (ETDEWEB)

    Strauss, M.G.; Westbrook, E.M.; Naday, I.; Coleman, T.A.; Westbrook, M.L.; Travis, D.J. (Argonne National Lab., IL (USA)); Sweet, R.M. (Brookhaven National Lab., Upton, NY (USA)); Pflugrath, J.W. (Cold Spring Harbor Lab., NY (USA)); Stanton, M. (Brandeis Univ., Waltham, MA (USA))

    1991-01-01

    A detector with a 114 mm aperture, based on a charge-coupled device (CCD), has been designed for x-ray diffraction studies in protein crystallography. The detector was tested on a beamline of the National Synchrotron Light Source at Brookhaven National Laboratory with a beam intensity greater than 10{sup 9} x-ray photons/s. A fiberoptic taper, an image intensifier and a lens demagnify, intensify, and focus the image onto a CCD having 512 {times} 512 pixels. A detective quantum efficiency (DOE) of 0.36 was obtained by evaluating the statistical uncertainty in the detector output. The dynamic range of a 4 {times} 4 pixel resolution element, comparable in size to a diffraction peak, was 10{sup 4}. The point-spread function shows FWHM resolution of approximately 1 pixel, where a pixel on the detector face is 160 {mu}m. A complete data set, consisting of forty-five 1{degree} rotation frames, was obtained in just 36 s of x-ray exposure to a crystal of chicken egg-white lysozyme. In a separate experiment, a lysozyme data set consisting of 495 0.1{degree} frames, was processed by the MADNES data reduction program, yielding symmetry R-factors for the data of 3.2--3.5%. Diffraction images from crystals of the myosin S1 head (a = 275 {Angstrom}) were also recorded. The Bragg spots, only 5 pixels apart, were resolved but were not sufficiently separated to process these data. Changes in the detector design which will improve the DQE and spatial resolution are outlined. The overall performance showed that this type of detector is well suited for x-ray scattering investigations with synchrotron sources. 23 refs., 11 figs.

  1. Large aperture CCD x ray detector for protein crystallography using a fiberoptic taper

    Science.gov (United States)

    Strauss, M. G.; Westbrook, E. M.; Naday, I.; Coleman, T. A.; Westbrook, M. L.; Travis, D. J.; Sweet, R. M.; Pflugrath, J. W.

    A detector with a 114 mm aperture, based on a charge-coupled device (CCD), has been designed for x-ray diffraction studies in protein crystallography. The detector was tested on a beamline of the National Synchrotron Light Source at Brookhaven National Laboratory with a beam intensity greater than 10(exp 9) x-ray photons/s. A fiberoptic taper, an image intensifier and a lens demagnify, intensify, and focus the image onto a CCD having 512 x 512 pixels. A detective quantum efficiency (DOE) of 0.36 was obtained by evaluating the statistical uncertainty in the detector output. The dynamic range of a 4 x 4 pixel resolution element, comparable in size to a diffraction peak, was 10(exp 4). The point-spread function shows FWHM resolution of approximately 1 pixel, where a pixel on the detector face is 160 microns. A complete data set, consisting of forty-five 1 deg rotation frames, was obtained in just 36 s of x-ray exposure to a crystal of chicken egg-white lysozyme. In a separate experiment, a lysozyme data set consisting of 495 0.1 deg frames, was processed by the MADNES data reduction program, yielding symmetry R-factors for the data of 3.2 to 3.5 percent. Diffraction images from crystals of the myosin S1 head (a = 275 A) were also recorded. The Bragg spots, only 5 pixels apart, were resolved but were not sufficiently separated to process these data. Changes in the detector design which will improve the DOE and spatial resolution are outlined. The overall performance showed that this type of detector is well suited for x-ray scattering investigations with synchrotron sources.

  2. Beam-beam and impedance

    CERN Document Server

    White, S.

    2014-07-17

    As two counter-rotating beams interact they can give rise to coherent dipole modes. Under the influence of impedance these coherent beam-beam modes can couple to higher order head-tail modes and lead to strong instabilities. A fully self-consistent approach including beam-beam and impedance was used to characterize this new coupled mode instability and study possible cures such as a transverse damper and high chromaticity.

  3. Individual taper models for natural cedar and Taurus fir mixed stands of Bucak Region, Turkey

    Directory of Open Access Journals (Sweden)

    Ramazan Özçelik

    2017-11-01

    Full Text Available In this study, we assessed the performance of different types of taper equations for predicting tree diameters at specific heights and total stem volumes for mixed stands of Taurus cedar (Cedrus libani A. Rich. and Taurus fir (Abies cilicica Carr.. We used data from mixed stands containing a total of 131 cedar and 124 Taurus fir trees. We evaluated six commonly used and well-known forestry taper functions developed by a variety of researchers (Biging (1984, Zakrzewski (1999, Muhairwe (1999, Fang et al. (2000, Kozak (2004, and Sharma and Zhang (2004. To address problems related to autocorrelation and multicollinearity in the hierarchical data associated with the construction of taper models, we used appropriate statistical procedures for the model fitting. We compared model performances based on the analysis of three goodness-of-fit statistics and found the compatible segmented model of Fang et al. (2000 to be superior in describing the stem profile and stem volume of both tree species in mixed stands. The equation used by Zakrzewski (1999 exhibited the poorest fitting results of the three taper equations. In general, we found segmented taper equations to provide more accurate predictions than variable-form models for both tree species. Results from the non-linear extra sum of squares method indicate that stem tapers differ among tree species in mixed stands. Therefore, a different taper function should be used for each tree species in mixed stands in the Bucak district. Using individual-specific taper equations yields more robust estimations and, therefore, will enhance the prediction accuracy of diameters at different heights and volumes in mixed stands.

  4. The Morse taper junction in modular revision hip replacement--a biomechanical and retrieval analysis.

    Science.gov (United States)

    Schramm, M; Wirtz, D C; Holzwarth, U; Pitto, R P

    2000-04-01

    All biomaterials used for total joint surgery are subjected to wear mechanisms. Morse taper junctions of modular hip revision implants are predilection sites for both fretting and crevice corrosion, dissociation and breakage of the components. The aim of this study is to quantify wear and study metallurgical changes of Morse taper junctions of in-vitro and in-vivo loaded modular revision stems. Three modular revision stems (MRP-Titan, Peter Brehm GmbH, Germany) were loaded by a servohydraulic testing machine. The loads and conditions used exceeded by far the values required by ISO-standard 7206. The tests were performed with maximum axial loads of 3,500 N to 4,000 N over 10-12 x 10(6) cycles at 2 Hz. Additionally, the female part of the taper junctions were coated with blood and bone debris. The free length of the implant was set to 200 mm. One other MRP stem was investigated after retrieval following 5.5 years of in-vivo use. All contact surfaces of the modular elements were assessed by visual inspection, optical microscopy and scanning electron microscopy (SEM). The degree of plastic deformation of the male part of the morse taper junction was determined by contouroscopy. None of the morse taper junctions broke or failed mechanically. Corrosion and wear affected all tapers, especially at the medial side. The retrieved implant showed no cracks and the amount of debris measured only one third of that for the stems tested in-vitro. The present retrieval and laboratory investigations have proven, that the morse taper junctions of the MRP-titanium stem are stable and resistant to relevant wear mechanisms. The longevity of the junctions for clinical use is given. If an optimal taper design is selected, the advantages of modular femoral components in total hip revision arthroplasty will outweigh the possible risks.

  5. Enhanced soliton self-frequency shift in a longitudinally varying taper

    DEFF Research Database (Denmark)

    Judge, A.C.; Bang, Ole; Eggleton, B.J.

    2009-01-01

    We propose a method for the enhancement of the soliton self-frequency shift in a tapered PCF with a carefully designed waist diameter profile which optimises the dispersion and nonlinearity at the soliton wavelength.......We propose a method for the enhancement of the soliton self-frequency shift in a tapered PCF with a carefully designed waist diameter profile which optimises the dispersion and nonlinearity at the soliton wavelength....

  6. Morse taper dental implants and platform switching: The new paradigm in oral implantology

    OpenAIRE

    Macedo, Jos? Paulo; Pereira, Jorge; Vahey, Brendan R.; Henriques, Bruno; Benfatti, Cesar A. M.; Magini, Ricardo S.; L?pez-L?pez, Jos?; Souza, J?lio C. M.

    2016-01-01

    The aim of this study was to conduct a literature review on the potential benefits with the use of Morse taper dental implant connections associated with small diameter platform switching abutments. A Medline bibliographical search (from 1961 to 2014) was carried out. The following search items were explored: ?Bone loss and platform switching,? ?bone loss and implant-abutment joint,? ?bone resorption and platform switching,? ?bone resorption and implant-abutment joint,? ?Morse taper and platf...

  7. Tapered-slit membrane filters for high-throughput viable circulating tumor cell isolation.

    Science.gov (United States)

    Kang, Yoon-Tae; Doh, Il; Cho, Young-Ho

    2015-04-01

    This paper presents tapered-slit membrane filters for high-throughput viable circulating tumor cell (CTC) isolation. The membrane filter with a 2D array of vertical tapered slits with a gap that is wide at the entrance and gradually decreases with depth, provide minimal cell stress and reduce 82.14% of the stress generated in conventional straight-hole filters. We designed two types of tapered-slit filters, Filters 6 and 8, respectively, containing the tapered slits with outlet widths of 6 μm and 8 μm at a slit density of 34,445/cm(2) on the membrane. We fabricated the vertical slits with a tapered angle of 2 ° on a SU8 membrane by adjusting the UV expose dose and the air gap between the membrane and the photomask during lithography. In the experimental study, the proposed tapered-slit filter captured 89.87% and 82.44% of the cancer cells spiked in phosphate buffered saline (PBS) and diluted blood (blood: PBS = 1:4), respectively, at a sample flow rate of 5 ml per hour, which is 33.3 times faster than previous lateral tapered-slit filters. We further verified the capability to culture on chip after capturing: 72.33% of cells among the captured cells still remained viable after a 5-day culture. The proposed tapered-slit membrane filters verified high-throughput viable CTC isolation capability, thereby inaugurating further advanced CTC research for cancer diagnosis and prognosis.

  8. Improvements to tapered semiconductor MOPA laser design and testing

    Science.gov (United States)

    Beil, James A.; Shimomoto, Lisa; Swertfeger, Rebecca B.; Misak, Stephen M.; Campbell, Jenna; Thomas, Jeremy; Renner, Daniel; Mashanovitch, Milan; Leisher, Paul O.; Liptak, Richard W.

    2018-02-01

    This paper expands on previous work in the field of high power tapered semiconductor amplifiers and integrated master oscillator power amplifier (MOPA) devices. The devices are designed for watt-class power output and single-mode operation for free-space optical communication. This paper reports on improvements to the fabrication of these devices resulting in doubled electrical-to-optical efficiency, improved thermal properties, and improved spectral properties. A newly manufactured device yielded a peak power output of 375 mW continuous-wave (CW) at 3000 mA of current to the power amplifier and 300 mA of current to the master oscillator. This device had a peak power conversion efficiency of 11.6% at 15° C, compared to the previous device, which yielded a peak power conversion efficiency of only 5.0% at 15° C. The new device also exhibited excellent thermal and spectral properties, with minimal redshift up to 3 A CW on the power amplifier. The new device shows great improvement upon the excessive self-heating and resultant redshift of the previous device. Such spectral improvements are desirable for free-space optical communications, as variation in wavelength can degrade signal quality depending on the detectors being used and the medium of propagation.

  9. Effects of intensified training and taper on immune function

    Directory of Open Access Journals (Sweden)

    Elena Papacosta

    2013-03-01

    Full Text Available Although resting immune function is not very different in athletes compared with non-athletes periods of intensified training (overreaching in already well trained athletes can result in a depression of immunity in the resting state. Illness-prone athletes appear to have an altered cytokine response to antigen stimulation and exercise. Having low levels of salivary IgA secretion also makes athletes more susceptible to upper respiratory tract infections. Overtraining is associated with recurrent infections and immunodepression is common, but immune functions do not seem to be reliable markers of impending overtraining. There are several possible causes of the diminution of immune function associated with periods of heavy training. One mechanism may simply be the cumulative effects of repeated bouts of intense exercise (with or without tissue damage with the consequent elevation of stress hormones, particularly glucocorticoids such as cortisol, causing temporary inhibition of TH-1 cytokines with a relative dampening of the cell-mediated response. When exercise is repeated frequently there may not be sufficient time for the immune system to recover fully. Tapering has been described as a gradual reduction in the training load which allows the recovery of physiological capacities that were impaired by previous intensive training and permits further training-induced adaptations to occur accompanied by competition performance enhancements. The majority of the studies that have examined the recovery of immunoendocrine responses during 1-3 week tapers in trained athletes have mainly reported enhanced performance, often accompanied by increased anabolic activity, reduced physiological stress and restoration of mucosal immunity and immune function.Quando se compara a função imune, em repouso, de atletas e não atletas, não se verificam grandes diferenças. Porém, períodos de treinamento intensificado ("overreaching" em atletas bem treinados podem

  10. Morse taper dental implants and platform switching: The new paradigm in oral implantology.

    Science.gov (United States)

    Macedo, José Paulo; Pereira, Jorge; Vahey, Brendan R; Henriques, Bruno; Benfatti, Cesar A M; Magini, Ricardo S; López-López, José; Souza, Júlio C M

    2016-01-01

    The aim of this study was to conduct a literature review on the potential benefits with the use of Morse taper dental implant connections associated with small diameter platform switching abutments. A Medline bibliographical search (from 1961 to 2014) was carried out. The following search items were explored: "Bone loss and platform switching," "bone loss and implant-abutment joint," "bone resorption and platform switching," "bone resorption and implant-abutment joint," "Morse taper and platform switching." "Morse taper and implant-abutment joint," Morse taper and bone resorption," "crestal bone remodeling and implant-abutment joint," "crestal bone remodeling and platform switching." The selection criteria used for the article were: meta-analysis; randomized controlled trials; prospective cohort studies; as well as reviews written in English, Portuguese, or Spanish languages. Within the 287 studies identified, 81 relevant and recent studies were selected. Results indicated a reduced occurrence of peri-implantitis and bone loss at the abutment/implant level associated with Morse taper implants and a reduced-diameter platform switching abutment. Extrapolation of data from previous studies indicates that Morse taper connections associated with platform switching have shown less inflammation and possible bone loss with the peri-implant soft tissues. However, more long-term studies are needed to confirm these trends.

  11. Buckling strength of tapered bridge girders under combined shear and bending

    Directory of Open Access Journals (Sweden)

    Metwally Abu-Hamd

    2016-08-01

    Full Text Available This paper represents the finite element results for the local buckling of tapered plate girders subjected to combine pure bending and shear stresses. An idealized model is developed representing the loading of the tapered panel that generates uniform normal stresses due to flexure, or uniform and constant shear stresses in the case of shear. Eigen-value analysis was performed for several tapered web plate girders that have different geometric parameters. A parametric study is made to reduce the FE model size showing the effect of decreasing the tapered panel adjacent straight panels, maintaining the same result accuracy as a complete girder model. The combined buckling capacity of bending and shear is determined by applying all possible load pattern combinations, together with different interaction ratios. An analysis study is presented to investigate the effect of the tapering angle on the combined bending–shear capacity of the girder. The study also includes the effect of the flange and web slenderness on the local buckling of the girder. Considering residual stresses as part of the loading stresses, the analysis procedure is repeated for some cases, and the effect of combining of the residual stresses together with the external loads is found. Empirical approximate formulae are given to estimate the combined flexure–shear buckling resistance of the tapered girder safely.

  12. Multi-segment tapered optical mirror for MEMS LiDAR application

    Science.gov (United States)

    Abdelsalam, Mostafa; Sabry, Yasser; Erfan, Mazen; Khalil, Diaa

    2017-02-01

    In this work, we present a novel and simple optical solution for MEMS LiDARs. The idea is based on increasing the collection optics throughput by removing the MEMS mirror from the path of the collected light, while inserting a multi-segment tapered structure to collect the light from a wide angle. The tapered also converts the large size optical spot captured to a small area compatible with the requirement of low detector noise dimensions. The expected improvement in the collected power is analyzed versus the tapering angle of a single tapered structure. A multi-segment optical system, or multiple tapered structure arranged in parallel, is also introduced allowing for the optimization of the acceptance angle and the power improvement ratio. Using a 3-segment mirror, the expected improvement is about 15x with an acceptance angle of +/-30 degrees. The design of a single element taper section is fabricated using aluminum-coated acrylic and tested experimentally showing an improvement of about 7x in the coupled power through an angle of +/-10 degrees in good agreement with the theoretical expectations.

  13. Beam cooling

    OpenAIRE

    Danared, H

    2006-01-01

    Beam cooling is the technique of reducing the momentum spread and increasing the phase-space density of stored particle beams. This paper gives an introduction to beam cooling and Liouville’s theorem, and then it describes the three methods of active beam cooling that have been proven to work so far, namely electron cooling, stochastic cooling, and laser cooling. Ionization cooling is also mentioned briefly.

  14. Molecular beams

    International Nuclear Information System (INIS)

    Pendelbury, J.M.; Smith, K.F.

    1987-01-01

    Studies with directed collision-free beams of particles continue to play an important role in the development of modern physics and chemistry. The deflections suffered by such beams as they pass through electric and magnetic fields or laser radiation provide some of the most direct information about the individual constituents of the beam; the scattering observed when two beams intersect yields important data about the intermolecular forces responsible for the scattering. (author)

  15. Quantitative evaluation of apically extruded debris during root canal instrumentation with ProTaper Universal, ProTaper Next, WaveOne, and self-adjusting file systems.

    Science.gov (United States)

    Ozsu, Damla; Karatas, Ertugrul; Arslan, Hakan; Topcu, Meltem C

    2014-10-01

    The aim of this study was to compare the amount of apically extruded debris during preparation with ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland), ProTaper Next (Dentsply Maillefer), a reciprocating single-file (WaveOne; VDW GmbH, Munich, Germany), and a self-adjusting file (SAF; ReDent Nova, Ra'anna, Israel). Fifty-six intact mandibular premolar teeth were randomly assigned to four groups. The root canals were prepared according to the manufacturers' instructions using the ProTaper Universal, ProTaper Next, WaveOne, and SAF. Apically extruded debris was collected in preweighted Eppendorf tubes during instrumentation. The net weight of the apically extruded debris was determined by subtracting the preweights and postweights of the tubes. The data were statistically analyzed using the one-way analysis of variance and the least significant difference tests at a significance level of P extruded in all groups, and the amounts of debris extrusion in the groups were statistically significant (P extruded debris beyond the apical foramen.

  16. Coupled fiber taper extraction of 1.53 microm photoluminescence from erbium doped silicon nitride photonic crystal cavities.

    Science.gov (United States)

    Shambat, Gary; Gong, Yiyang; Lu, Jesse; Yerci, Selçuk; Li, Rui; Dal Negro, Luca; Vucković, Jelena

    2010-03-15

    Optical fiber tapers are used to collect photoluminescence emission at approximately 1.5 microm from photonic crystal cavities fabricated in erbium doped silicon nitride on silicon. In the experiment, photoluminescence collection via one arm of the fiber taper is enhanced 2.5 times relative to free space collection, corresponding to a net collection efficiency of 4%. Theoretically, the collection efficiency into one arm of the fiber-taper with this material system and cavity design can be as high as 12.5%, but the degradation of the experimental coupling efficiency relative to this value mainly comes from scattering loss within the short taper transition regions. By varying the fiber taper offset from the cavity, a broad tuning range of coupling strength and collection efficiency is obtained. This material system combined with fiber taper collection is promising for building on-chip optical amplifiers.

  17. Studying energy absorption in tapered thick walled tubes

    Directory of Open Access Journals (Sweden)

    P. Hosseini Tehrani

    Full Text Available In many engineering structures different energy absorption systems may be used to improve crashworthiness capability of the system and to control damages that may occur in a system during an accident. Therefore, extensive research has been done on the energy-absorbing cells. In this paper, energy absorption in tapered thick walled tubes has been investigated. As a practical case, studies have been focused on the crush element of Siemens ER24PC locomotive. To investigate performance of this part at collision time, it has been modeled in Abaqus software and its collision characteristics have been evaluated. Considering that the crash element is folded at time of collision, an analytical approach has been presented for calculation of instantaneous folding force under axial load. Basis of this method is definition and analysis of main folding mechanism and calculation of average folding force. This method has been used for validation of the results of numerical solution. Since sheet thickness of the crash element is high and may be ruptured at time of collision, some damage models have been used for numerical simulations. One of the three damage models used in this paper is available in the software and coding has been done for two other damage models and desirable damage model has been specified by comparing results of numerical solution with results of laboratory test. In addition, authenticity of the desirable damage model has been studied through ECE R 66 standard. To improve crashworthiness characteristic some attempts, such as use of metal foam and creation of trigger in suitable situations to reduce maximum force resulting from collision, have been performed. Finally though different simulation optimal crush element has been introduced and its performance and efficiency have been evaluated.

  18. Opioid Tapering in Fibromyalgia Patients: Experience from an Interdisciplinary Pain Rehabilitation Program.

    Science.gov (United States)

    Cunningham, Julie L; Evans, Michele M; King, Susan M; Gehin, Jessica M; Loukianova, Larissa L

    2016-09-01

    Despite current guideline recommendations against the use of opioids for the treatment of fibromyalgia pain, opioid use is reported in approximately 30% of the patient population. There is a lack of information describing the process and results of tapering of chronic opioids. The purpose of this study is to describe opioid tapering and withdrawal symptoms in fibromyalgia patients on opioids. This retrospective research study included a baseline analysis of 159 patients consecutively admitted to the Mayo Clinic Pain Rehabilitation Center from 2006 through 2012 with a pain diagnosis of fibromyalgia completing a 3-week outpatient interdisciplinary pain rehabilitation program. Opioid tapering analysis included 55 (35%) patients using daily opioids. Opioid tapering was individualized to each patient based on interdisciplinary pain rehabilitation team determination. Opioid withdrawal symptoms were assessed daily, utilizing the Clinical Opioid Withdrawal Scale. Patients taking daily opioids had a morphine equivalent mean dose of 99 mg/day. Patients on  200 mg/day over a mean of 28 days (P 2 years duration. Patients had significant improvements in pain-related measures including numeric pain scores, depression catastrophizing, health perception, interference with life, and perceived life control at program completion. Fibromyalgia patients on higher doses of opioids were tapered off over a longer period of time but no differences in withdrawal symptoms were seen based on opioid dose. Duration of opioid use did not affect the time to complete opioid taper or withdrawal symptoms. Despite opioid tapering, pain-related measures improved at the completion of the rehabilitation program. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  19. Influence of the Prosthetic Index on Fracture Resistance of Morse Taper Dental Implants.

    Science.gov (United States)

    Zancopé, Karla; Dias Resende, Caio César; Castro, Carolina Guimarães; Salatti, Rafael Calixto; Domingues das Neves, Flávio

    Manufacturers have inserted a prosthetic index, an internal hexagon to guide prosthetic components inside Morse taper implants. However, it is still unclear if this mechanism could decrease the mechanical strength of Morse taper implants. The aim of this study was to evaluate the influence of the prosthetic index inside Morse taper implants on fracture resistance compared with nonindexed implants. Fifty-seven Morse taper implants, with 11.5-degree angulation of the internal conical portion, were divided into three groups: implants without the prosthetic index and solid Morse taper universal post (group 1), implants with the prosthetic index and solid Morse taper universal post (group 2), and implants and abutments with the prosthetic index (group 3). All groups were modeled for finite element stress analysis (FEA), simulating force application of a perpendicular load to the abutments. Fracture resistance (n = 10) was determined under the same condition. Dynamic loading (n = 9) was also performed. The statistical analysis was performed using one-way analysis of variance (ANOVA), and the Tukey test was applied (α = .05). The metallographic analysis was used to identify the fracture distribution and the microstructure of the titanium alloy. There was no statistically significant difference between the values of all tested groups. According to the FEA, the prosthetic index region was out of stress. The mean fracture resistances and loading test were 353.7 N and 200 N for group 1, 397.3 N and 170 N for group 2, and 372.0 N and 160 N for group 3, respectively. Metallographic analysis showed a macroscopic failure pattern just as demonstrated by FEA. The presence of the prosthetic index on Morse taper implants did not decrease its resistance to fracture for the tested implants.

  20. Development and evaluation of teak (Tectona grandis L.f. taper equations in northern Thailand

    Directory of Open Access Journals (Sweden)

    Andrew J. Warner

    2016-09-01

    Full Text Available Taper refers to the general decrease in the regular outline of a solid body from its base to its tip. Taper models are used to estimate the volume and value of wood products from harvesting trees. Teak (Tectona grandis L.f. is highly valued as one of the world's most preferred timbers and a teak taper equation is required to inform optimal harvesting strategies given the limited plantation resource available in Thailand. Teak taper equations were developed and evaluated based on 331 sample trees collected in 2014 from eight plantations in northern Thailand aged from 10 to 46 yr using two taper model formulations—the Kozak variable-exponent taper model and the Goodwin cubic polynomial model comprising hyperbolic and parabolic terms. Variants based on both model types were fitted using nonlinear regression analysis with diameter at breast height, total tree height and height of girth measurement as the independent variables to estimate diameter underbark at the nominated height. Goodness-of-fit and leave-one-out cross validation with lack-of-fit statistical testing combined with extensive graphical analysis of residuals were used to select the best model. A Goodwin model variant (named FIO-teak1 as the first plantation teak taper model known to be published in Thailand provided the best estimates of volume and diameter underbark. A simple case study confirmed that FIO-teak1 in combination with the Farm Forestry Toolbox software package could assist teak plantation managers in decision making associated with optimizing log grade value based on standing tree inventory data.

  1. Beam diagnostics

    International Nuclear Information System (INIS)

    Bogaty, J.; Clifft, B.E.; Zinkann, G.P.; Pardo, R.C.

    1995-01-01

    The ECR-PII injector beam line is operated at a fixed ion velocity. The platform high voltage is chosen so that all ions have a velocity of 0.0085c at the PII entrance. If a previous tune configuration for the linac is to be used, the beam arrival time must be matched to the previous tune as well. A nondestructive beam-phase pickup detector was developed and installed at the entrance to the PII linac. This device provides continuous phase and beam current information and allows quick optimization of the beam injected into PII. Bunches traverse a short tubular electrode thereby inducing displacement currents. These currents are brought outside the vacuum interface where a lumped inductance resonates electrode capacitance at one of the bunching harmonic frequencies. This configuration yields a basic sensitivity of a few hundred millivolts signal per microampere of beam current. Beam-induced radiofrequency signals are summed against an offset frequency generated by our master oscillator. The resulting kilohertz difference frequency conveys beam intensity and bunch phase information which is sent to separate processing channels. One channel utilizes a phase locked loop which stabilizes phase readings if beam is unstable. The other channel uses a linear full wave active rectifier circuit which converts kilohertz sine wave signal amplitude to a D.C. voltage representing beam current. A prototype set of electronics is now in use with the detector and we began to use the system in operation to set the arrival beam phase. A permanent version of the electronics system for the phase detector is now under construction. Additional nondestructive beam intensity and phase monitors at the open-quotes Boosterclose quotes and open-quotes ATLASclose quotes linac sections are planned as well as on some of the high-energy beam lines. Such a monitor will be particularly useful for FMA experiments where the primary beam hits one of the electric deflector plates

  2. A numerical study of Taylor vortex flow in a finite length tapered annulus

    International Nuclear Information System (INIS)

    Noui-Mehidi, M N; Ohmura, N; Wu, J

    2005-01-01

    The transient evolution and steady state analysis of Taylor vortex flow in a tapered annulus was conducted by numerical experiments in the case where the inner cylinder was rotated and the outer one fixed. The gap between the cylinders was linearly tapered from a supercritical value at the upper base to the critical value at the lower base. The wavelength adjustment depended on the variation of Reynolds number in the spatially ramped gap. The axisymmetric conservative governing equations were solved by the use of an simplified marker and cell (SMAC) algorithm. A coordinate transformation function allowed us to numerically solve the problem in a rectangular computational domain. The results have shown that Taylor vortices growth was sensitive to the spatial ramp of the gap even with tapering angle values less than one degree. The interaction between the inflow and outflow boundaries could be clearly seen as the taper angle was increased. The investigation of the transient dynamics related to the flow system also revealed a characteristic dependence on the taper angle

  3. The Nonlinear Dynamic Behaviour of Tapered Laminated Plates Subjected to Blast Loading

    Directory of Open Access Journals (Sweden)

    Sedat Susler

    2012-01-01

    Full Text Available In this study, the geometrically nonlinear dynamic behaviour of simply supported tapered laminated composite plates subjected to the air blast loading is investigated numerically. In-plane stiffness, inertia and the geometric nonlinearity effects are considered in the formulation of the problem. The equations of motion for the tapered laminated plate are derived by the use of the virtual work principle. Approximate solution functions are assumed for the space domain and substituted into the equations of motion. Then, the Galerkin method is used to obtain the nonlinear algebraic differential equations in the time domain. The resulting equations are solved by using the finite difference approximation over the time. The effects of the taper ratio, the stacking sequence and the fiber orientation angle on the dynamic response are investigated. The displacement-time and strain-time histories are obtained on certain points in the tapered direction. The results obtained by using the present method are compared with the ones obtained by using a commercial finite element software ANSYS. The results are found to be in an agreement. The method presented here is able to determine the nonlinear dynamic response of simply supported tapered laminated plates to the air blast loading accurately.

  4. The Effect of Vibration Characteristics on the Atomization Rate in a Micro-Tapered Aperture Atomizer.

    Science.gov (United States)

    Yan, Qiufeng; Zhang, Jianhui; Huang, Jun; Wang, Ying

    2018-03-21

    Because little is known about the atomization theory of a micro-tapered aperture atomizer, we investigated the vibration characteristics of this type of atomizer. The atomization mechanism of a micro-tapered aperture atomizer was described, and the atomization rate equation was deduced. As observed via microscopy, the angle of the micro-tapered aperture changes with the applied voltage, which proved the existence of a dynamic cone angle. The forward and reverse atomization rates were measured at various voltages, and the influence of the micro-tapered aperture and its variation on the atomization rate was characterized. The resonance frequency of the piezoelectric vibrator was obtained using a laser vibrometer, and the atomization rates were measured at each resonance frequency. From experiments, we found that the atomization rates at the first five resonance frequencies increased as the working frequency increased. At the fifth resonance frequency (121.1 kHz), the atomization rate was maximized (0.561 mL/min), and at the sixth resonance frequency (148.3 kHz), the atomization rate decreased significantly (0.198 mL/min). The experimental results show that the vibration characteristics of the piezoelectric vibrator have a relatively strong impact on the atomization rate. This research is expected to contribute to the manufacture of micro-tapered aperture atomizers.

  5. The Effect of Vibration Characteristics on the Atomization Rate in a Micro-Tapered Aperture Atomizer

    Directory of Open Access Journals (Sweden)

    Qiufeng Yan

    2018-03-01

    Full Text Available Because little is known about the atomization theory of a micro-tapered aperture atomizer, we investigated the vibration characteristics of this type of atomizer. The atomization mechanism of a micro-tapered aperture atomizer was described, and the atomization rate equation was deduced. As observed via microscopy, the angle of the micro-tapered aperture changes with the applied voltage, which proved the existence of a dynamic cone angle. The forward and reverse atomization rates were measured at various voltages, and the influence of the micro-tapered aperture and its variation on the atomization rate was characterized. The resonance frequency of the piezoelectric vibrator was obtained using a laser vibrometer, and the atomization rates were measured at each resonance frequency. From experiments, we found that the atomization rates at the first five resonance frequencies increased as the working frequency increased. At the fifth resonance frequency (121.1 kHz, the atomization rate was maximized (0.561 mL/min, and at the sixth resonance frequency (148.3 kHz, the atomization rate decreased significantly (0.198 mL/min. The experimental results show that the vibration characteristics of the piezoelectric vibrator have a relatively strong impact on the atomization rate. This research is expected to contribute to the manufacture of micro-tapered aperture atomizers.

  6. Comparison of primary stability of straight-walled and tapered implants using an insertion torque device.

    Science.gov (United States)

    Menicucci, Giulio; Pachie, Emanuela; Lorenzetti, Massimo; Migliaretti, Giuseppe; Carossa, Stefano

    2012-01-01

    Implant geometry has a major impact on insertion torque values and primary stability, and bone engagement during implant insertion differs according to implant morphology. Primary stability of straight-walled and tapered implants was compared using insertion torque monitoring. A total of 57 implants (36 straight-walled OSSEOTITE and 21 tapered OSSEOTITE NT) were inserted in 20 patients. Implant torque values and insertion times were recorded, and the data were processed and interpolated to determine torque as a function of time. Tapered implants required less insertion time and a higher insertion torque than straight-walled implants; this provided better primary stability, although the success rate was 86% for tapered and 100% for straight-walled implants. Tapered implants showed better primary stability than straight-walled implants but had a lower success rate. The authors suggest that in low-density bone, in which only a thin dense cortical layer can contribute to primary stability, a higher insertion torque can lead to the destruction of peri-implant bone, compromising osseointegration.

  7. Effect of sequence dispersity on morphology of tapered diblock copolymers from molecular dynamics simulations.

    Science.gov (United States)

    Levine, William G; Seo, Youngmi; Brown, Jonathan R; Hall, Lisa M

    2016-12-21

    Tapered diblock copolymers are similar to typical AB diblock copolymers but have an added transition region between the two blocks which changes gradually in composition from pure A to pure B. This tapered region can be varied from 0% (true diblock) to 100% (gradient copolymer) of the polymer length, and this allows some control over the microphase separated domain spacing and other material properties. We perform molecular dynamics simulations of linearly tapered block copolymers with tapers of various lengths, initialized from fluids density functional theory predictions. To investigate the effect of sequence dispersity, we compare systems composed of identical polymers, whose taper has a fixed sequence that most closely approximates a linear gradient, with sequentially disperse polymers, whose sequences are created statistically to yield the appropriate ensemble average linear gradient. Especially at high segregation strength, we find clear differences in polymer conformations and microstructures between these systems. Importantly, the statistical polymers are able to find more favorable conformations given their sequence, for instance, a statistical polymer with a larger fraction of A than the median will tend towards the A lamellae. The conformations of the statistically different polymers can thus be less stretched, and these systems have higher overall density. Consequently, the lamellae formed by statistical polymers have smaller domain spacing with sharper interfaces.

  8. Coupling Characteristics of Fused Optical Fiber Coupler Formed with Single-Mode Fiber and Photonic Crystal Fiber Having Air Hole Collapsed Taper

    Directory of Open Access Journals (Sweden)

    Hirohisa Yokota

    2016-01-01

    Full Text Available Fused coupler forming with a single-mode fiber (SMF and a photonic crystal fiber (PCF is one of the solutions for optical coupling from a light source to a PCF. In this paper, we presented coupling characteristics of a fused fiber coupler formed with an ordinary SMF and a PCF having air hole collapsed taper. A prototype of SMF-PCF coupler with air hole collapsed taper was fabricated using CO2 laser irradiation. The coupling efficiency from SMF to PCF was −6.2 dB at 1554 nm wavelength in the fabricated coupler. The structure of the SMF-PCF coupler to obtain high coupling efficiency was theoretically clarified by beam propagation analysis using an equivalent model of the coupler with simplification. It was clarified that appropriately choosing the prestretched or etched SMF diameter and the length of air hole collapsed region was effective to obtain high coupling efficiency that was a result of high extinction ratio at cross port and low excess loss. We also demonstrated that the diameter of prestretched SMF to obtain high coupling efficiency was insensitive to the air hole diameter ratio to pitch of the PCF in the air hole collapsed SMF-PCF coupler.

  9. A non-reflecting boundary for use in a finite element beam model of a railway track

    Science.gov (United States)

    Yang, Jiannan; Thompson, David J.

    2015-02-01

    Some beam-like structures such as a railway track are effectively infinite in nature. Analytical solutions exist for simple structures but numerical methods like the finite element (FE) method are often employed to study more complicated problems. However, when the FE method is used for structures of infinite extent it is essential to introduce artificial boundaries to limit the area of computation. Here, a non-reflecting boundary is developed using a damped tapered tip for application in a finite element model representing an infinite supported beam. The FE model of the tapered tip is validated against an analytical model based on Bessel functions. The reflection characteristics of the FE tapered tip are quantified using a wave/FE superposition method. It is shown that the damped tapered tip is much more effective than its constant counterpart and achieves reduction of the model size. The damped tapered tip is applied to a simple FE railway track model and good agreement is found when its point mobility is compared with an analytical infinite track model.

  10. Development of a prototype tapered cell drift chamber

    International Nuclear Information System (INIS)

    Blissett, J.A.; Hasell, D.K.; Kendall, E.W.; Payne, B.T.; Saxon, D.H.

    1984-06-01

    Drift chamber cells have been constructed and tested using an electron test beam facility at DESY. The cells were operated under different voltage conditions and with different gas mixtures at 1 bar. Aspects of the construction and operation are discussed. Resolutions were typically less than 100 microns. The dependence of the drift cell resolution on distance from the sense wire and operating conditions are presented. (author)

  11. Development of a prototype tapered cell drift chamber

    International Nuclear Information System (INIS)

    Blissett, J.A.; Hasell, D.K.; Kendall, E.W.; Payne, B.T.; Saxon, D.H.

    1984-01-01

    Drift chamber cells have been constructed and tested using an electron test beam facility at DESY. The cells were operated under different voltage conditions and with different gas mixtures at 1 bar. Aspects of the construction and operation are discussed. Resolutions were typically less than 100 μm. The dependence of the drift cell resolution on distance from the sense wire and operating conditions are presented. (orig.)

  12. Corrosion of the Head-Stem Taper Junction-Are We on the Verge of an Epidemic?: Review Article.

    Science.gov (United States)

    Morlock, Michael; Bünte, Dennis; Gührs, Julian; Bishop, Nicholas

    2017-02-01

    The modular head taper junction has contributed to the success of total hip arthroplasty (THA) greatly. Taper corrosion and wear problems reported for large and extra-large metal-on-metal bearings as well as for bi-modular THA stems have cast doubt on the benefit of the taper interface. Presently, corrosion problems are being reported for nearly all kinds of artificial hip joints incorporating metal heads, questioning taper connections in general. This study aimed to review the mechanical and electrochemical relationships that may lead to taper corrosion, which have been reported more commonly in recent literature, and to also review the contribution of patient characteristics and surgical techniques involved in taper assembly that may contribute to the problem. The search criteria "(corrosion) AND (hip arthroplasty) AND (taper OR trunnion)" and "(hip arthroplasty) AND ((pseudotumor) OR (pseudo-tumor))" in PubMed and the JAAOS were used for the literature search. In addition, the arthroplasty registers were considered. Most studies acknowledge the multifactorial nature of the problem but concentrate their analysis on taper and implant design aspects, since this is the only factor that can be easily quantified. The sometimes conflicting results in the literature could be due to the fact that the other two decisive factors are not sufficiently considered: the loading situation in the patient and the assembly situation by the surgeon. All three factors together determine the fate of a taper junction in THA. There is no single reason as a main cause for taper corrosion. The combined "outcome" of these three factors has to be in a "safe range" to achieve a successful long-term taper fixation. No, this is not the beginning of an epidemic. It is rather the consequence of disregarding known mechanical and electrochemical relationships, which in combination have recently caused a more frequent occurrence-and mainly reporting-of corrosion issues.

  13. Modular taper junction corrosion and failure: how to approach a recalled total hip arthroplasty implant.

    Science.gov (United States)

    Pivec, Robert; Meneghini, R Michael; Hozack, William J; Westrich, Geoffrey H; Mont, Michael A

    2014-01-01

    Corrosion at the modular neck-stem taper junction has become an increasingly important topic as several reports have identified this couple as a possible source for early failure with findings similar to failed metal-on-metal hip arthroplasties. Recently, two different modular stem systems from a single manufacturer were voluntarily recalled due to concerns of failure of the modular taper junction. We discuss how to approach the diagnosis and management of patients with these particular stem systems. We further reviewed the literature to evaluate whether this is a manufacturer-specific defect or indicative of a broader trend. Recent studies appear to implicate the basic design of the neck-stem taper junction, rather than a single manufacturer, which is at high risk for fretting and corrosion. © 2013.

  14. Influence of convective conditions in radiative peristaltic flow of pseudoplastic nanofluid in a tapered asymmetric channel

    Energy Technology Data Exchange (ETDEWEB)

    Hayat, T. [Department of Mathematics, Quaid-I-Azam University 45320, Islamabad 44000 (Pakistan); Nonlinear Analysis and Applied Mathematics (NAAM) Research Group, Department of Mathematics, Faculty of Science, King Abdulaziz University, Jeddah 21589 (Saudi Arabia); Iqbal, Rija [Department of Mathematics, Quaid-I-Azam University 45320, Islamabad 44000 (Pakistan); Tanveer, Anum, E-mail: qau14@yahoo.com [Department of Mathematics, Quaid-I-Azam University 45320, Islamabad 44000 (Pakistan); Alsaedi, A. [Nonlinear Analysis and Applied Mathematics (NAAM) Research Group, Department of Mathematics, Faculty of Science, King Abdulaziz University, Jeddah 21589 (Saudi Arabia)

    2016-06-15

    This paper looks at the influences of magnetohydrodynamics (MHD) and thermal radiation on peristaltic transport of a pseudoplastic nanofluid in a tapered asymmetric channel. The tapered channel walls satisfy convective boundary conditions. The governing equations for the balance of mass, momentum, temperature and volume fraction for pseudoplastic nanofluid are first formulated and then utilized for long wavelength and small Reynolds number considerations. Effects of involved parameters on the flow characteristics have been plotted and examined. It is observed that the heat transfer Biot number shows a dual behavior on the temperature of nanofluid particles whereas the mass transfer Biot number with its increasing values enhances the fluid temperature. - Highlights: • Mathematical model for peristalsis of pseudoplastic nanofluid is formulated. • Analysis has been made in a tapered asymmetric channel. • Magnetohydrodynamic aspects have been outlined. • Influence of thermal radiation is investigated. • Convective conditions for both heat and mass transfer are present.

  15. Experimental observation of breathing solitons and a third harmonic in a tapered photonic crystal fiber

    Science.gov (United States)

    Wang, F.; Yao, C. F.; Li, C. Z.; Jia, Z. X.; Li, Q.; Wu, C. F.; Ohishi, Y.; Qin, W. P.; Qin, G. S.

    2018-02-01

    We report the experimental observation of breathing solitons and a third harmonic in a tapered fluorotellurite photonic crystal fiber (PCF) pumped by a 1560 nm femtosecond fiber laser. The PCF has a core diameter that varies continuously along its length, resulting in a zero-dispersion wavelength that moves from 1325 nm to 906 nm over the transition region. By finely controlling the dispersion map of the tapered PCF and increasing the order of the optical solitons, their breathing behavior is observed in the frequency domain and the number of breaths goes up to 9. Furthermore, the breathing behavior of the optical soliton is transferred to the third harmonic through inter-modal phase-matched processes in the tapered PCF, and the third harmonic also breathes with an increase in the pump power.

  16. Up-taper-based Mach-Zehnder interferometer for temperature and strain simultaneous measurement.

    Science.gov (United States)

    Kang, Zexin; Wen, Xiaodong; Li, Chao; Sun, Jiang; Wang, Jing; Jian, Shuisheng

    2014-04-20

    A novel all-fiber sensing configuration for simultaneous measurements of temperature and strain based on the up-taper Mach-Zehnder interferometer (MZI) with an in-line embedded fiber Bragg grating (FBG) is proposed and experimentally demonstrated. This configuration consists of two up-tapers fabricated by an excessive fusion splicing method and a short segment of inscribed FBG. Due to the different responses of the up-taper MZI and the FBG to the uniform variation of temperature and strain, the simultaneous measurement for these two variables could be achieved by real-time monitoring the transmission spectrum. For 0.01 nm wavelength resolution, a resolution of 0.311°C in temperature can be achieved, and the average strain resolution is 10.07 με.

  17. Elliptical beams.

    Science.gov (United States)

    Bandres, Miguel A; Gutiérrez-Vega, Julio C

    2008-12-08

    A very general beam solution of the paraxial wave equation in elliptic cylindrical coordinates is presented. We call such a field an elliptic beam (EB). The complex amplitude of the EB is described by either the generalized Ince functions or the Whittaker-Hill functions and is characterized by four parameters that are complex in the most general situation. The propagation through complex ABCD optical systems and the conditions for square integrability are studied in detail. Special cases of the EB are the standard, elegant, and generalized Ince-Gauss beams, Mathieu-Gauss beams, among others.

  18. Efficient Mid-Infrared Supercontinuum Generation in Tapered Large Mode Area Chalcogenide Photonic Crystal Fibers

    DEFF Research Database (Denmark)

    Petersen, Christian Rosenberg; Engelsholm, Rasmus Dybbro; Markos, Christos

    2017-01-01

    Mid-infrared supercontinuum spanning from 1.8-9  μm with an output power of 41.5 mW is demonstrated by pumping tapered large mode area chalcogenide photonic crystal fibers using a 4 μm optical parametric source.......Mid-infrared supercontinuum spanning from 1.8-9  μm with an output power of 41.5 mW is demonstrated by pumping tapered large mode area chalcogenide photonic crystal fibers using a 4 μm optical parametric source....

  19. Influence of convective conditions in radiative peristaltic flow of pseudoplastic nanofluid in a tapered asymmetric channel

    Science.gov (United States)

    Hayat, T.; Iqbal, Rija; Tanveer, Anum; Alsaedi, A.

    2016-06-01

    This paper looks at the influences of magnetohydrodynamics (MHD) and thermal radiation on peristaltic transport of a pseudoplastic nanofluid in a tapered asymmetric channel. The tapered channel walls satisfy convective boundary conditions. The governing equations for the balance of mass, momentum, temperature and volume fraction for pseudoplastic nanofluid are first formulated and then utilized for long wavelength and small Reynolds number considerations. Effects of involved parameters on the flow characteristics have been plotted and examined. It is observed that the heat transfer Biot number shows a dual behavior on the temperature of nanofluid particles whereas the mass transfer Biot number with its increasing values enhances the fluid temperature.

  20. Improving field enhancement of 2D hollow tapered waveguides via dielectric microcylinder coupling

    International Nuclear Information System (INIS)

    Chen, Yongzhu; Chen, Gengyan; Guo, Lina; Lin, Xusheng; Xie, Xiangsheng; Li, Li

    2015-01-01

    We numerically study a novel scheme to improve the field enhancement of 2D hollow tapered waveguides (HTWs). A dielectric microcylinder is embedded into a metal–insulator–metal (MIM) HTW for resonant exciting gap surface plasmons (GSPs), which is different from the lowest propagating mode (TM 0 ) excitation via the conventional fire-end coupling method. The physical mechanism of the field enhancement and the influence of critical parameters such as numerical aperture (NA) of the lens, permittivity of the microcylinder and the incident wavelength are discussed. The substantial improvement of the GSP excitation efficiency via dielectric microcylinder coupling shows potential in designing tapered MIM waveguides for nanofocusing and field enhancement. (paper)

  1. High force measurement sensitivity with fiber Bragg gratings fabricated in uniform-waist fiber tapers

    International Nuclear Information System (INIS)

    Wieduwilt, Torsten; Brückner, Sven; Bartelt, Hartmut

    2011-01-01

    Fiber Bragg gratings inscribed in the waist of tapered photosensitive fibers offer specific attractive properties for sensing applications. A small-diameter fiber reduces structural influences for imbedded fiber sensing elements. In the case of application as a force-sensing element for tensile forces, sensitivity scales inversely with the fiber cross-sectional area. It is therefore possible to increase force sensitivity by several orders of magnitude compared to Bragg grating sensors in conventionally sized fibers. Special requirements for such Bragg grating arrangements are discussed and experimental measurements for different fiber taper diameters down to 4 µm are presented

  2. Studies of geometrical profiling in fabricated tapered optical fibers using whispering gallery modes spectroscopy

    Science.gov (United States)

    Kavungal, Vishnu; Farrell, Gerald; Wu, Qiang; Kumar Mallik, Arun; Semenova, Yuliya

    2018-03-01

    This paper experimentally demonstrates a method for geometrical profiling of asymmetries in fabricated thin microfiber tapers with waist diameters ranging from ∼10 to ∼50 μm with submicron accuracy. The method is based on the analysis of whispering gallery mode resonances excited in cylindrical fiber resonators as a result of evanescent coupling of light propagating through the fiber taper. The submicron accuracy of the proposed method has been verified by SEM studies. The method can be applied as a quality control tool in fabrication of microfiber based devices and sensors or for fine-tuning of microfiber fabrication set-ups.

  3. Laser cooling of a magnetically guided ultra cold atom beam

    International Nuclear Information System (INIS)

    Aghajani-Talesh, Anoush

    2014-01-01

    This thesis examines two complimentary methods for the laser cooling of a magnetically guided ultra-cold atom beam. If combined, these methods could serve as a starting point for high-through put and possibly even continuous production of Bose-Einstein condensates. First, a mechanism is outlined to harvest ultra cold atoms from a magnetically guided atom beam into an optical dipole trap. A continuous loading scheme is described that dissipates the directed kinetic energy of a captured atom via deceleration by a magnetic potential barrier followed by optical pumping to the energetically lowest Zeeman sublevel. The application of this scheme to the transfer of ultra cold chromium atoms from a magnetically guided atom beam into a deep optical dipole trap is investigated via numerical simulations of the loading process. Based on the results of the theoretical studies the feasibility and the efficiency of our loading scheme, including the realisation of a suitable magnetic field configuration, are analysed. Second, experiments were conducted on the transverse laser cooling of a magnetically guided beam of ultra cold chromium atoms. Radial compression by a tapering of the guide is employed to adiabatically heat the beam. Inside the tapered section heat is extracted from the atom beam by a two-dimensional optical molasses perpendicular to it, resulting in a significant increase of atomic phase space density. A magnetic offset field is applied to prevent optical pumping to untrapped states. Our results demonstrate that by a suitable choice of the magnetic offset field, the cooling beam intensity and detuning, atom losses and longitudinal heating can be avoided. Final temperatures below 65 μK have been achieved, corresponding to an increase of phase space density in the guided beam by more than a factor of 30.

  4. Evaluation of the Painful Dual Taper Modular Neck Stem Total Hip Arthroplasty: Do They All Require Revision?

    Science.gov (United States)

    Kwon, Young-Min

    2016-07-01

    Although dual taper modular-neck total hip arthroplasty (THA) design with additional neck-stem modularity has the potential to optimize hip biomechanical parameters by facilitating adjustments of leg length, femoral neck version and offset, there is increasing concern regarding this stem design as a result of the growing numbers of adverse local tissue reactions due to fretting and corrosion at the neck-stem taper junction. Implant factors such as taper cone angle, taper surface roughness, taper contact area, modular neck taper metallurgy, and femoral head size play important roles in influencing extent of taper corrosion. There should be a low threshold to conduct a systematic clinical evaluation of patients with dual-taper modular-neck stem THA using systematic risk stratification algorithms as early recognition and diagnosis will ensure prompt and appropriate treatment. Although specialized tests such as metal ion analysis and cross-sectional imaging modalities such as metal artifact reduction sequence magnetic resonance imaging (MARS MRI) are useful in optimizing clinical decision-making, overreliance on any single investigative tool in the clinical decision-making process for revision surgery should be avoided. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Experimental Measurement of the Static Coefficient of Friction at the Ti-Ti Taper Connection in Total Hip Arthroplasty

    NARCIS (Netherlands)

    Bitter, T.; Khan, I.; Marriott, T.; Schreurs, B.W.; Verdonschot, Nicolaas Jacobus Joseph; Janssen, D.

    2016-01-01

    The modular taper junction in total hip replacements has been implicated as a possible source of wear. The finite-element (FE) method can be used to study the wear potential at the taper junction. For such simulations it is important to implement representative contact parameters, in order to

  6. Efficient concept for generation of diffraction-limited green light by sum-frequency generation of spectrally combined tapered diode lasers.

    Science.gov (United States)

    Müller, André; Jensen, Ole Bjarlin; Hasler, Karl-Heinz; Sumpf, Bernd; Erbert, Götz; Andersen, Peter E; Petersen, Paul Michael

    2012-09-15

    In order to increase the power of visible diode laser systems in an efficient manner, we propose spectral beam combining with subsequent sum-frequency generation. We show that this approach, in comparison with second harmonic generation of single emitters, can enhance the available power significantly. By combining two distributed Bragg reflector tapered diode lasers we achieve a 2.5-3.2 fold increase in power and a maximum of 3.9 W of diffraction-limited green light. At this power level, green diode laser systems have a high application potential, e.g., within the biomedical field. Our concept can be expanded combining multiple diode lasers to increase the power even further.

  7. A large taper mismatch is one of the key factors behind high wear rates and failure at the taper junction of total hip replacements: A finite element wear analysis.

    Science.gov (United States)

    Ashkanfar, Ariyan; Langton, David J; Joyce, Thomas J

    2017-05-01

    Total hip replacement (THR) is one of the most successful orthopaedic surgeries; however, failures can occur due to adverse reactions to wear debris. Recently, a large number of failures linked to the release of metal particles from the taper junction between femoral head and femoral stem have been reported. One possible reason for this may be design variations such as taper mismatches associated with the taper and trunnion angles. Could a large taper mismatch lead to inappropriate contact mechanics and increase relative micromotion and thus wear? In this study, 3D finite element (FE) models of a commercial THR from a perfectly matched interface to large taper mismatches and a wear algorithm were used to investigate the extent of wear that could occur at this junction and identify the optimum tolerances in order to reduce the wear. A co-ordinate measuring machine (CMM) was used to analyse the wear depth and volumetric wear rate of the tapers of 54 explanted 36mm diameter Cobalt Chromium femoral heads, which had been in service for 5.1 years in average, to validate the FE analyses. It was found that a large taper mismatch (e.g. 9.12´) results in a high wear rate (2.960mm 3 per million load cycles). Such wear rates can have a major negative effect on the clinical outcomes of these implants. It was also found that even a slight reduction in mismatch significantly reduced the magnitude of the wear rates (0.069mm 3 per million load cycles on average for 6´ taper mismatch). It is recommended that the cone angles of femoral head and femoral trunnion should be manufactured to produce a taper mismatch of less than 6´ at the taper junction. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Superresolution beams

    CSIR Research Space (South Africa)

    Ngcobo, S

    2012-07-01

    Full Text Available positions of p zeros of intensity distributions on the Gaussian beam, resulting to a generation of TEMp0 beams where there are minimum losses. The LGBs are well-known family of exact orthogonal solutions of free-space paraxial wave equation in cylindrical...

  9. Beam diagnostics

    CERN Document Server

    Raich, U

    2008-01-01

    Most beam measurements are based on the electro-magnetic interaction of fields induced by the beam with their environment. Beam current transformers as well as beam position monitors are based on this principle. The signals induced in the sensors must be amplified and shaped before they are converted into numerical values. These values are further treated numerically in order to extract meaningful machine parameter measurements. The lecture introduces the architecture of an instrument and shows where in the treatment chain digital signal analysis can be introduced. Then the use of digital signal processing is presented using tune measurements, orbit and trajectory measurements as well as beam loss detection and longitudinal phase space tomography as examples. The hardware as well as the treatment algorithms and their implementation on Digital Signal Processors (DSPs) or in Field Programmable Gate Arrays (FPGAs) are presented.

  10. Quantitative evaluation of debris extruded apically by using ProTaper Universal Tulsa rotary system in endodontic retreatment.

    Science.gov (United States)

    Huang, Xiangya; Ling, Junqi; Wei, Xi; Gu, Lisha

    2007-09-01

    This study evaluated the amount of apical debris during endodontic retreatment by using the ProTaper Universal Tulsa rotary files. Forty-five extracted human anterior teeth were root filled before randomly assigned to 3 groups. In group A, gutta-percha was removed by using the ProTaper Universal Tulsa retreatment system, and canals were re-prepared with ProTaper rotary files. In group B, gutta-percha was removed by using Hedström files with chloroform, and canals were reshaped with ProTaper rotary files. In group C, the same method as that in group B was used for gutta-percha removal, and canals were reshaped with K-flex files. Apical debris was collected and compared among 3 groups. Although all retreatment techniques resulted in apical extrusion, the ProTaper Universal Tulsa rotary technique in group A produced significantly less amount of apical extrusion than other 2 methods (P endodontic retreatment.

  11. Electron beam welding using fusion and cold wire fill

    International Nuclear Information System (INIS)

    Kuncz, F.F.

    1977-01-01

    A straight-fusion (self-filler) welding technique generally poses no problem for electron beam welding. However, where control of penetration is a critical item and burn-through cannot be tolerated, this technique may not be satisfactory. To assure against beam-spike burn-through on a 1/4-inch deep weld joint, a low-power root-fusion pass, supplemented by numerous filler passes, was selected. However, this technique proved to have numerous problems. Voiding and porosity showed frequently in the first applications of this cold-wire filler process. Taper-out cratering, bead-edge undercutting, and spatter were also problems. These imperfections, however, were overcome. Employment of a circle generator provided the necessary heating of the joint walls to eliminate voids. The moving beam spot also provided a stirring action, lessening porosity. Taper-out cratering was eliminated by adjusting the timing of the current cutoff and wire-feed cutoff. Undercutting, bead height, and spatter were controlled by beam defocus

  12. Research of beam hardening correction method for CL system based on SART algorithm

    International Nuclear Information System (INIS)

    Cao Daquan; Wang Yaxiao; Que Jiemin; Sun Cuili; Wei Cunfeng; Wei Long

    2014-01-01

    Computed laminography (CL) is a non-destructive testing technique for large objects, especially for planar objects. Beam hardening artifacts were wildly observed in the CL system and significantly reduce the image quality. This study proposed a novel simultaneous algebraic reconstruction technique (SART) based beam hardening correction (BHC) method for the CL system, namely the SART-BHC algorithm in short. The SART-BHC algorithm took the polychromatic attenuation process in account to formulate the iterative reconstruction update. A novel projection matrix calculation method which was different from the conventional cone-beam or fan-beam geometry was also studied for the CL system. The proposed method was evaluated with simulation data and experimental data, which was generated using the Monte Carlo simulation toolkit Geant4 and a bench-top CL system, respectively. All projection data were reconstructed with SART-BHC algorithm and the standard filtered back projection (FBP) algorithm. The reconstructed images show that beam hardening artifacts are greatly reduced with the SART-BHC algorithm compared to the FBP algorithm. The SART-BHC algorithm doesn't need any prior know-ledge about the object or the X-ray spectrum and it can also mitigate the interlayer aliasing. (authors)

  13. Tapered toothbrush filaments in relation to gingival abrasion, removal of plaque and treatment of gingivitis

    NARCIS (Netherlands)

    Versteeg, P.A.; Piscaer, M.; Rosema, N.A.M.; Timmerman, M.F.; van der Velden, U.; van der Weijden, G.A.

    2008-01-01

    Objectives: To compare a tapered filament toothbrush (TFTB) to a control toothbrush (ADA) in their potential to cause gingival abrasion and improve the gingival condition following a period of experimental gingivitis. Methods: Thirty-two subjects refrained from brushing mandibular teeth for 21 days.

  14. Influence of stem type on material loss at the metal-on-metal pinnacle taper junction.

    Science.gov (United States)

    Hothi, Harry S; Whittaker, Robert K; Meswania, Jay M; Blunn, Gordon W; Skinner, John A; Hart, Alister J

    2015-01-01

    The clinical importance of material loss at the head-stem junction is unknown. Comparison of retrievals with different stem types can provide the opportunity to understand the importance of the taper junction. This was a case-control study involving 20 retrieved 36 mm metal-on-metal Pinnacle (DePuy) hips that were paired with either a Corail (n = 10) or S-ROM (n = 10) stem. The median head taper material loss rate for the Corail group was 0.238 (0.0002-2.178) mm(3)/year and was significantly greater than the S-ROM group (p = 0.042), which had a median material loss rate of 0.132 (0.015-0.518) mm(3)/year. The only significant difference between the groups was the stem taper roughness and length: this was rougher and shorter for the Corails. Long and smooth stem taper designs are preferred when used in conjunction with metal heads. © IMechE 2015.

  15. Duodenal Derotation and Extent Tapering Jejunoplasty as Primary Repair for Neonates With High Jejunal Atresia

    Directory of Open Access Journals (Sweden)

    Chih-Cheng Luo

    2010-10-01

    Conclusion: In very proximal high atresia, the extent of tapering is limited by the proximity of the ligament of Treitz. Duodenal derotation provides better access to the high atresia. The results of this limited experience suggest that the DDETJ procedure could provide an alternative therapy in patients with high jejunal atresia.

  16. A mechanical model of wing and theoretical estimate of taper factor ...

    Indian Academy of Sciences (India)

    Likewise, by using the data linear regression and curve estimation method, as well as estimating the taper factors and the angle between the humerus and the body, we calculated the relationship between wingspan, wing area and the speed necessary to meet the aerodynamic requirements of sustained flight. In addition ...

  17. Automated quantification of bronchiectasis, airway wall thickening and lumen tapering in chest CT

    DEFF Research Database (Denmark)

    Perez-Rovira, Adria; Kuo, Wieying; Petersen, Jens

    Purpose: To automatically quantify airway structural properties visualised on CT in children with cystic fibrosis (CF) and controls, including: bronchiectasis, airway wall thickening, and lumen tapering. Methods and materials: The 3D surface of the airway lumen, outer wall, and bronchial arteries...

  18. A mechanical model of wing and theoretical estimate of taper factor ...

    Indian Academy of Sciences (India)

    PRAKASH

    β angle between humerus and body βmin minimum angle between humerus and body βe empirical span ratio (bobs/ bmax) βmin,sr minimum span ratio b wing span. bB body width bmax maximum wing span bobs observed wingspan c wing chord. Cl,max maximum lift coefficient e taper factor g acceleration due to gravity.

  19. Investigation of the particle flowpattern and segregation in tapered fluidized bed granulators

    NARCIS (Netherlands)

    Schaafsma, S. H.; Marx, T.; Hoffmann, A. C.

    The particle flowpattern and granule segregation in tapered fluidized beds have been studied using two techniques. The first technique is to fluidize beds of varying total mass and granule fractions, then defluidize them suddenly to "freeze" the composition, section the bed in layers, and determine

  20. Efficient synthesis of large-scale thinned arrays using a density-taper initialised genetic algorithm

    CSIR Research Space (South Africa)

    Du Plessis, WP

    2011-09-01

    Full Text Available The use of the density-taper approach to initialise a genetic algorithm is shown to give excellent results in the synthesis of thinned arrays. This approach is shown to give better SLL values more consistently than using random values and difference...

  1. Vibration-Assisted Femtosecond Laser Drilling with Controllable Taper Angles for AMOLED Fine Metal Mask Fabrication

    Directory of Open Access Journals (Sweden)

    Wonsuk Choi

    2017-02-01

    Full Text Available This study investigates the effect of focal plane variation using vibration in a femtosecond laser hole drilling process on Invar alloy fabrication quality for the production of fine metal masks (FMMs. FMMs are used in the red, green, blue (RGB evaporation process in Active Matrix Organic Light-Emitting Diode (AMOLED manufacturing. The taper angle of the hole is adjusted by attaching the objective lens to a micro-vibrator and continuously changing the focal plane position. Eight laser pulses were used to examine how the hole characteristics vary with the first focal plane’s position, where the first pulse is focused at an initial position and the focal planes of subsequent pulses move downward. The results showed that the hole taper angle can be controlled by varying the amplitude of the continuously operating vibrator during femtosecond laser hole machining. The taper angles were changed between 31.8° and 43.9° by adjusting the vibrator amplitude at a frequency of 100 Hz. Femtosecond laser hole drilling with controllable taper angles is expected to be used in the precision micro-machining of various smart devices.

  2. Restorasi Resin Komposit Menggunakan Pasak Tapered Self Threading Pada Molar Ketiga Kiri Mandibula

    Directory of Open Access Journals (Sweden)

    Ellen Krisanti

    2013-06-01

    Composite Resin Restoration Using Tapered Self Threading Poston Left Mandibular Third Molar. Root canal morphology of mandibular third molar has more complex variation than the other molars. In third molar, the extraction teeth are often executed; however, the third molar can be maintained in other conditions. One visit root canal treatment is a therapy option for this case. The purpose of this case report is to show the success of one visit root canal treatment in third molar with pulp necrosis by restoring the composite resin through tapered self-treading post. A 20 year-old female patient who came to the Prof Soedomo RSGM, FKG UGM complained about the pain when chewing food on her third molar and positive in percussion. The radiographs showed that there was an incomplete restoration. There was a gap between cavities with restoration. The treatment plan for this case was one visit root canal treatment and composite resin with tapered self-threading post as final restoration. From the case, it can concluded that one visit root canal treatment results in a smaller chance for microorganism recontamination than the multi-visit in order to ensure the success of the treatment. Direct composite resin restoration with tapered self-threading dowel is an alternative restoration after endodontic treatment because it works out faster and more retentive.

  3. Effects of Prosthesis Stem Tapers on Stress Distribution of Cemented Hip Arthroplasty

    International Nuclear Information System (INIS)

    Abdullah, Abdul Halim; Nor, Mohd Asri Mohd; Saman, Alias Mohd; Tamin, Mohd Nasir; Kadir, Mohammed Rafiq Abdul

    2010-01-01

    Aseptic loosening effects are critical issues in encouraging long term stability of cemented hip arthroplasty. Stress shielding is believed to be an important factor that contributes to the aseptic loosening problems. The numerous changes in the prosthesis stem design are intended to minimize the stress shielding and aseptic loosening problems and to improve the long term performance of the implants. In this study, the stress distribution in cemented hip arthroplasty is established using finite element method. The taper of the prosthesis is designed to be 3 deg. at anterior/posterior, 3 deg. at medial/lateral and 10 deg. from wide lateral to narrow medial. Major muscle loads and contact forces are simulated for walking (toe-off phase) and stair climbing load cases. Effects of prosthesis stem tapers on the resulting stress distribution are investigated. Results show that compressive stress dominates in the medial plane while tensile stress in the lateral plane of the femur. The corresponding stress levels of intact femur for walking and stair-climbing load cases are 22 and 29 MPa, respectively. The magnitude of Tresca stress for the THA femur in stair-climbing load case remains higher in the region of 85 MPa while the walking load case induces around 40 MPa. The stress range in the straight and single taper stem prosthesis is lower than 260 MPa, while localized Tresca stress is in the order of the yield strength of Ti-6Al-4V alloy for double and triple taper stem design.

  4. Finite element modeling of small-scale tapered wood-laminated composite poles with biomimicry features

    Science.gov (United States)

    Cheng Piao; Todd F. Shupe; R.C. Tang; Chung Y. Hse

    2008-01-01

    Tapered composite poles with biomimicry features as in bamboo are a new generation of wood laminated composite poles that may some day be considered as an alternative to solid wood poles that are widely used in the transmission and telecommunication fields. Five finite element models were developed with ANSYS to predict and assess the performance of five types of...

  5. Tapered Optical Fiber Sensor for Label-Free Detection of Biomolecules

    Directory of Open Access Journals (Sweden)

    Xingwei Wang

    2011-03-01

    Full Text Available This paper presents a fast, highly sensitive and low-cost tapered optical fiber biosensor that enables the label-free detection of biomolecules. The sensor takes advantage of the interference effect between the fiber’s first two propagation modes along the taper waist region. The biomolecules bonded on the taper surface were determined by demodulating the transmission spectrum phase shift. Because of the sharp spectrum fringe signals, as well as a relatively long biomolecule testing region, the sensor displayed a fast response and was highly sensitive. To better understand the influence of various biomolecules on the sensor, a numerical simulation that varied biolayer parameters such as thickness and refractive index was performed. The results showed that the spectrum fringe shift was obvious to be measured even when the biolayer was only nanometers thick. A microchannel chip was designed and fabricated for the protection of the sensor and biotesting. Microelectromechanical systems (MEMS fabrication techniques were used to precisely control the profile and depth of the microchannel on the silicon chip with an accuracy of 2 μm. A tapered optical fiber biosensor was fabricated and evaluated with an Immune globulin G (IgG antibody-antigen pair.

  6. Design of Ultra-Wideband Tapered Slot Antenna by Using Binomial Transformer with Corrugation

    Science.gov (United States)

    Chareonsiri, Yosita; Thaiwirot, Wanwisa; Akkaraekthalin, Prayoot

    2017-05-01

    In this paper, the tapered slot antenna (TSA) with corrugation is proposed for UWB applications. The multi-section binomial transformer is used to design taper profile of the proposed TSA that does not involve using time consuming optimization. A step-by-step procedure for synthesis of the step impedance values related with step slot widths of taper profile is presented. The smooth taper can be achieved by fitting the smoothing curve to the entire step slot. The design of TSA based on this method yields results with a quite flat gain and wide impedance bandwidth covering UWB spectrum from 3.1 GHz to 10.6 GHz. To further improve the radiation characteristics, the corrugation is added on the both edges of the proposed TSA. The effects of different corrugation shapes on the improvement of antenna gain and front-to-back ratio (F-to-B ratio) are investigated. To demonstrate the validity of the design, the prototypes of TSA without and with corrugation are fabricated and measured. The results show good agreement between simulation and measurement.

  7. Narrow line width operation of a 980 nm gain guided tapered diode laser bar

    DEFF Research Database (Denmark)

    Vijayakumar, Deepak; Jensen, Ole Bjarlin; Barrientos-Barria, Jessica

    2011-01-01

    We demonstrate two different schemes for the spectral narrowing of a 12 emitter 980 nm gain guided tapered diode laser bar. In the first scheme, a reflective grating has been used in a Littman Metcalf configuration and the wavelength of the laser emission could be narrowed down from more than 5.5...

  8. Near-unity efficiency, single-photon sources based on tapered photonic nanowires

    DEFF Research Database (Denmark)

    Bleuse, Joël; Munsch, Mathieu; Claudon, Julien

    2012-01-01

    Single-photon emission from excitons in InAs Quantum Dots (QD) embedded in GaAs Tapered Photonic Wires (TPW) already demonstrated a 0.72 collection efficiency, with TPWs were the apex is the sharp end of the cone. Going to alternate designs, still based on the idea of the adiabatic deconfinement...

  9. Effects of Prosthesis Stem Tapers on Stress Distribution of Cemented Hip Arthroplasty

    Science.gov (United States)

    Abdullah, Abdul Halim; Nor, Mohd Asri Mohd; Saman, Alias Mohd; Tamin, Mohd Nasir; Kadir, Mohammed Rafiq Abdul

    2010-10-01

    Aseptic loosening effects are critical issues in encouraging long term stability of cemented hip arthroplasty. Stress shielding is believed to be an important factor that contributes to the aseptic loosening problems. The numerous changes in the prosthesis stem design are intended to minimize the stress shielding and aseptic loosening problems and to improve the long term performance of the implants. In this study, the stress distribution in cemented hip arthroplasty is established using finite element method. The taper of the prosthesis is designed to be 3° at anterior/posterior, 3° at medial/lateral and 10° from wide lateral to narrow medial. Major muscle loads and contact forces are simulated for walking (toe-off phase) and stair climbing load cases. Effects of prosthesis stem tapers on the resulting stress distribution are investigated. Results show that compressive stress dominates in the medial plane while tensile stress in the lateral plane of the femur. The corresponding stress levels of intact femur for walking and stair-climbing load cases are 22 and 29 MPa, respectively. The magnitude of Tresca stress for the THA femur in stair-climbing load case remains higher in the region of 85 MPa while the walking load case induces around 40 MPa. The stress range in the straight and single taper stem prosthesis is lower than 260 MPa, while localized Tresca stress is in the order of the yield strength of Ti-6Al-4V alloy for double and triple taper stem design.

  10. Controlling coarse woody debris inventory quality: taper and relative size methods

    Science.gov (United States)

    C.W. Woodall; J.A. Westfall

    2008-01-01

    Accurately measuring the dimensions of coarse woody debris (CWD) is critical for ensuring the quality of CWD estimates and, hence, for accurately estimating forest ecosystem attributes (e.g., CWD carbon stocks). To improve the quality of CWD dimensional measurements, the distribution of taper (ratio of change in diameter and length) and relative size (RS; ratio of...

  11. Simulation and analysis of sensitivity for tapered fiber Bragg grating evanescent wave sensor

    Science.gov (United States)

    Xu, Hong-zhi; Lou, Jun; Tan, Yao-cheng; Li, Ben-chong; Huang, Jie; Shen, Wei-min

    2014-12-01

    We have carried out a detailed simulative study of the tapered fiber Bragg grating (TFBG) evanescent wave sensor sensitivity by using 3-D Coupled-Mode Theory method. The method is based on the spectral interrogation mode of operation. We also make numerical simulations to figure out how the uniform waist diameter and the difference of the relative refractive indexes between fiber core and external medium affect the sensitivity of this proposed sensor. The simulation results show that the sensitivity of the tapered fiber Bragg grating will be improved when the diameter of the uniform waist decrease as well as the difference of the relative refractive indexes between fiber core and external medium. And with the fixed uniform waist diameter and tapered length, when the difference of the relative refractive index of fiber core and external medium varies is 0.015RIU, the values of wavelength shift is 5.08nm, the sensitivity of the tapered fiber Bragg grating is 317.5nm/RIU. The sensitivity is higher than that of the common FBG. The results are consistent with theoretical models. The simulation results can supply the guidance for the further experimental study and refractive index sensor design, optimization and application.

  12. Immediate placement of tapered effect (TE) implants: 5-year results of a prospective, multicenter study.

    Science.gov (United States)

    Wilson, Thomas G; Roccuzzo, Mario; Ucer, Cemal; Beagle, Jay R

    2013-01-01

    To evaluate the success and survival of immediately placed tapered implants to support fixed restorations in the maxilla and mandible. The study was a prospective, multicenter, non-interventional study of patients requiring tooth extraction who requested an implant-supported restoration in the maxilla or mandible. Patients received at least one tapered implant (either immediately after tooth extraction or at a later time point). Abutments were placed 42 to 56 days after surgery, and prostheses were placed after a further 14 days. Treatment and implant success were the primary effectiveness criteria, and secondary parameters included radiographic bone loss, patient satisfaction, and gingival health. A total of 436 patients were enrolled, of whom 376 were included in the safety analysis. Single implants were placed in 77% of patients, two implants in 16%, and three or more implants in the remainder. The cumulative implant survival rates for immediately placed implants were 98.3% after 1 year and 97.7% from 2 to 5 years. Patient satisfaction was good or excellent in most patients and the majority of implants showed no or immediately placed tapered implants was comparable to that found in other studies. Immediate implant placement with tapered implants can allow rapid rehabilitation with no adverse impact on implant survival.

  13. Biorheological Model on Flow of Herschel-Bulkley Fluid through a Tapered Arterial Stenosis with Dilatation.

    Science.gov (United States)

    Priyadharshini, S; Ponalagusamy, R

    2015-01-01

    An analysis of blood flow through a tapered artery with stenosis and dilatation has been carried out where the blood is treated as incompressible Herschel-Bulkley fluid. A comparison between numerical values and analytical values of pressure gradient at the midpoint of stenotic region shows that the analytical expression for pressure gradient works well for the values of yield stress till 2.4. The wall shear stress and flow resistance increase significantly with axial distance and the increase is more in the case of converging tapered artery. A comparison study of velocity profiles, wall shear stress, and flow resistance for Newtonian, power law, Bingham-plastic, and Herschel-Bulkley fluids shows that the variation is greater for Herschel-Bulkley fluid than the other fluids. The obtained velocity profiles have been compared with the experimental data and it is observed that blood behaves like a Herschel-Bulkley fluid rather than power law, Bingham, and Newtonian fluids. It is observed that, in the case of a tapered stenosed tube, the streamline pattern follows a convex pattern when we move from r/R = 0 to r/R = 1 and it follows a concave pattern when we move from r/R = 0 to r/R = -1. Further, it is of opposite behaviour in the case of a tapered dilatation tube which forms new information that is, for the first time, added to the literature.

  14. Biorheological Model on Flow of Herschel-Bulkley Fluid through a Tapered Arterial Stenosis with Dilatation

    Directory of Open Access Journals (Sweden)

    S. Priyadharshini

    2015-01-01

    Full Text Available An analysis of blood flow through a tapered artery with stenosis and dilatation has been carried out where the blood is treated as incompressible Herschel-Bulkley fluid. A comparison between numerical values and analytical values of pressure gradient at the midpoint of stenotic region shows that the analytical expression for pressure gradient works well for the values of yield stress till 2.4. The wall shear stress and flow resistance increase significantly with axial distance and the increase is more in the case of converging tapered artery. A comparison study of velocity profiles, wall shear stress, and flow resistance for Newtonian, power law, Bingham-plastic, and Herschel-Bulkley fluids shows that the variation is greater for Herschel-Bulkley fluid than the other fluids. The obtained velocity profiles have been compared with the experimental data and it is observed that blood behaves like a Herschel-Bulkley fluid rather than power law, Bingham, and Newtonian fluids. It is observed that, in the case of a tapered stenosed tube, the streamline pattern follows a convex pattern when we move from r/R=0 to r/R=1 and it follows a concave pattern when we move from r/R=0 to r/R=-1. Further, it is of opposite behaviour in the case of a tapered dilatation tube which forms new information that is, for the first time, added to the literature.

  15. Vibration-Assisted Femtosecond Laser Drilling with Controllable Taper Angles for AMOLED Fine Metal Mask Fabrication

    Science.gov (United States)

    Choi, Wonsuk; Kim, Hoon Young; Jeon, Jin Woo; Chang, Won Seok; Cho, Sung-Hak

    2017-01-01

    This study investigates the effect of focal plane variation using vibration in a femtosecond laser hole drilling process on Invar alloy fabrication quality for the production of fine metal masks (FMMs). FMMs are used in the red, green, blue (RGB) evaporation process in Active Matrix Organic Light-Emitting Diode (AMOLED) manufacturing. The taper angle of the hole is adjusted by attaching the objective lens to a micro-vibrator and continuously changing the focal plane position. Eight laser pulses were used to examine how the hole characteristics vary with the first focal plane’s position, where the first pulse is focused at an initial position and the focal planes of subsequent pulses move downward. The results showed that the hole taper angle can be controlled by varying the amplitude of the continuously operating vibrator during femtosecond laser hole machining. The taper angles were changed between 31.8° and 43.9° by adjusting the vibrator amplitude at a frequency of 100 Hz. Femtosecond laser hole drilling with controllable taper angles is expected to be used in the precision micro-machining of various smart devices. PMID:28772571

  16. High energy supercontinuum sources using tapered photonic crystal fibers for multispectral photoacoustic microscopy

    DEFF Research Database (Denmark)

    Bondu, Magalie; Brooks, Christopher; Jakobsen, Christian

    2016-01-01

    We demonstrate a record bandwidth high energy supercontinuum source suitable for multispectral photoacoustic microscopy. The source has more than 150  nJ/10  nm150  nJ/10  nm bandwidth over a spectral range of 500 to 1600 nm. This performance is achieved using a carefully designed fiber taper wit...

  17. Tapered Microfluidic for Continuous Micro-Object Separation Based on Hydrodynamic Principle.

    Science.gov (United States)

    Ahmad, Ida Laila; Ahmad, Mohd Ridzuan; Takeuchi, Masaru; Nakajima, Masahiro; Hasegawa, Yasuhisa

    2017-12-01

    Recent advances in microfluidic technologies have created a demand for a simple and efficient separation intended for various applications such as food industries, biological preparation, and medical diagnostic. In this paper, we report a tapered microfluidic device for passive continuous separation of microparticles by using hydrodynamic separation. By exploiting the hydrodynamic properties of the fluid flow and physical characteristics of micro particles, effective size based separation is demonstrated. The tapered microfluidic device has widening geometries with respect to specific taper angle which amplify the sedimentation effect experienced by particles of different sizes. A mixture of 3-μm and 10-μm polystyrene microbeads are successfully separated using 20° and 25° taper angles. The results obtained are in agreement with three-dimensional finite element simulation conducted using Abaqus 6.12. Moreover, the feasibility of this mechanism for biological separation is demonstrated by using polydisperse samples consists of 3-μm polystyrene microbeads and human epithelial cervical carcinoma (HeLa) cells. 98% of samples purity is recovered at outlet 1 and outlet 3 with flow rate of 0.5-3.0 μl/min. Our device is interesting despite adopting passive separation approach. This method enables straightforward, label-free, and continuous separation of multiparticles in a stand-alone device without the need for bulky apparatus. Therefore, this device may become an enabling technology for point of care diagnosis tools and may hold potential for micrototal analysis system applications.

  18. IBPAT/OSHA Health and Safety Education Quiz Book. Painters, Abrasive Blasters, Tapers, Paint Makers, Floorcoverers.

    Science.gov (United States)

    International Brotherhood of Painters and Allied Trades, Washington, DC.

    Designed for use by instructors using the "Health and Safety Education Book" (International Brotherhood of Painters and Allied Trades/Occupational Safety and Health Act), this book contains quizzes specifically for painters, abrasive blasters, tapers, paint makers, and floorcoverers. Quizzes included in the book focus on testing areas such as (1)…

  19. Adalimumab Dose Tapering in Psoriasis: Predictive Factors for Maintenance of Complete Clearance.

    Science.gov (United States)

    Hansel, Katharina; Bianchi, Leonardo; Lanza, Francesco; Bini, Vittorio; Stingeni, Luca

    2017-03-10

    Psoriasis can be managed successfully with long-term biologics. Real-life clinical practice may require dose tapering as a therapeutic option to reduce the risk of drug-exposure and to increase cost-effectiveness. The responsiveness to extended intervals between adalimumab doses and the possible predictive factors of maintenance of complete clearance were studied in a retrospective 7-year single-centre analysis. Thirty patients who achieved complete clearance with adalimumab underwent dose tapering, progressively extending between-dose intervals (to 21-28 days). Sixty percent of subjects (group A) maintained complete clearance, whereas 40.0% (group B) relapsed and were switched back to the standard dosage to re-achieve complete clearance. Body mass index (BMI) and time to achieve Psoriasis Area Severity Index (PASI-100) with adalimumab standard treatment before dose tapering were significantly lower in group A than in group B (multi-variate Cox regression: p < 0.05, Kaplan-Meier analysis: p < 0.001, respectively). This study suggests that patients with lower BMI and shorter time to achieve PASI-100 with adalimumab standard dose were significantly more likely to be candidates for dose tapering.

  20. Friction Stir Welding of Tapered Thickness Welds Using an Adjustable Pin Tool

    Science.gov (United States)

    Adams, Glynn; Venable, Richard; Lawless, Kirby

    2003-01-01

    Friction stir welding (FSW) can be used for joining weld lands that vary in thickness along the length of the weld. An adjustable pin tool mechanism can be used to accomplish this in a single-pass, full-penetration weld by providing for precise changes in the pin length relative to the shoulder face during the weld process. The difficulty with this approach is in accurately adjusting the pin length to provide a consistent penetration ligament throughout the weld. The weld technique, control system, and instrumentation must account for mechanical and thermal compliances of the tooling system to conduct tapered welds successfully. In this study, a combination of static and in-situ measurements, as well as active control, is used to locate the pin accurately and maintain the desired penetration ligament. Frictional forces at the pin/shoulder interface were a source of error that affected accurate pin position. A traditional FSW pin tool design that requires a lead angle was used to join butt weld configurations that included both constant thickness and tapered sections. The pitch axis of the tooling was fixed throughout the weld; therefore, the effective lead angle in the tapered sections was restricted to within the tolerances allowed by the pin tool design. The sensitivity of the FSW process to factors such as thickness offset, joint gap, centerline offset, and taper transition offset were also studied. The joint gap and the thickness offset demonstrated the most adverse affects on the weld quality. Two separate tooling configurations were used to conduct tapered thickness welds successfully. The weld configurations included sections in which the thickness decreased along the weld, as well as sections in which the thickness increased along the weld. The data presented here include weld metallography, strength data, and process load data.

  1. Tapering clonazepam in patients with panic disorder after at least 3 years of treatment.

    Science.gov (United States)

    Nardi, Antonio E; Freire, Rafael C; Valença, Alexandre M; Amrein, Roman; de Cerqueira, Ana Claudia R; Lopes, Fabiana L; Nascimento, Isabella; Mezzasalma, Marco A; Veras, André B; Sardinha, Aline; de Carvalho, Marcele R; da Costa, Rafael T; Levitan, Michelle N; de-Melo-Neto, Valfrido L; Soares-Filho, Gastão L; Versiani, Marcio

    2010-06-01

    High-potency benzodiazepines, such as clonazepam, are frequently used in the treatment of panic disorder (PD) because of their rapid onset of action and good tolerability. However, there is concern about their potential to cause withdrawal symptoms. We aimed to develop a protocol for safely tapering off clonazepam in patients with PD who had been receiving treatment for at least 3 years. A specific scale for judging withdrawal was also developed, the Composite Benzodiazepine Discontinuation Symptom Scale. We selected 73 patients with PD who had been asymptomatic for at least 1 year and who wished to discontinue the medication. The trial consisted of a 4-month period of tapering and an 8-month follow-up period. The dosage of clonazepam was decreased by 0.5 mg per 2-week period until 1 mg per day was reached, followed by a decrease of 0.25 mg per week. The mean dosage at the start of tapering was 2.7 +/- 1.2 mg/d. In total, 51 (68.9%) of the patients were free of the medication after the 4 months of tapering according to the protocol, and 19 (26.0%) of the patients needed another 3 months to be free of medication. Clonazepam discontinuation symptoms were mostly mild and included mainly: anxiety, shaking/trembling/tremor, nausea/vomiting, insomnia/nightmares, excessive sweating, tachycardia/palpitations, headache, weakness, and muscle aches. The improvement in PD and general well-being was maintained during both the taper and follow-up phases. Clonazepam can be successfully discontinued without any major withdrawal symptoms if the dose is reduced gradually. We recommend reducing the dosage of clonazepam after intermediate-term use by 0.25 mg/wk.

  2. Molecular beams

    International Nuclear Information System (INIS)

    Ramsey, N.F.

    1985-01-01

    This book is a timeless and rather complete theoretical and experimental treatment of electric and magnetic resonance molecular-beam experiments for studying the radio frequency spectra of atoms and molecules. The theory of interactions of the nucleus with atomic and molecular fields is extensively presented. Measurements of atomic and nuclear magnetic moments, electric multipole moments, and atomic fine and hyperfine structure are detailed. Useful but somewhat outdated chapters on gas kinetics, molecular beam design, and experimental techniques are also included

  3. Beam transport

    International Nuclear Information System (INIS)

    1988-01-01

    Considerable experience has now been gained with the various beam transport lines, and a number of minor changes have been made to improve the ease of operation. These include: replacement of certain little-used slits by profile monitors (harps or scanners); relocation of steering magnets, closer to diagnostic harps or profile scanners; installation of a scanner inside the isocentric neutron therapy system; and conversion of a 2-doublet quadrupole telescope (on the neutron therapy beamline) to a 2-triplet telescope. The beam-swinger project has been delayed by very late delivery of the magnet iron to the manufacturer, but is now progressing smoothly. The K=600 spectrometer magnets have now been delivered and are being assembled for field mapping. The x,y-table with its associated mapping equipment is complete, together with the driver software. One of the experimental areas has been dedicated to the production of collimated neutron beams and has been equipped with a bending magnet and beam dump, together with steel collimators fixed at 4 degrees intervals from 0 degrees to 16 degrees. Changes to the target cooling and shielding system for isotope production have led to a request for much smaller beam spot sizes on target, and preparations have been made for rearrangement of the isotope beamline to permit installation of quadrupole triplets on the three beamlines after the switching magnet. A practical system of quadrupoles for matching beam properties to the spectrometer has been designed. 6 figs

  4. Defining dosing pattern characteristics of successful tapers following methadone maintenance treatment: results from a population-based retrospective cohort study.

    Science.gov (United States)

    Nosyk, Bohdan; Sun, Huiying; Evans, Elizabeth; Marsh, David C; Anglin, M Douglas; Hser, Yih-Ing; Anis, Aslam H

    2012-09-01

    To identify dose-tapering strategies associated with sustained success following methadone maintenance treatment (MMT). Population-based retrospective cohort study. Linked administrative medication dispensation data from British Columbia, Canada. From 25 545 completed MMT episodes, 14 602 of which initiated a taper, 4183 individuals (accounting for 4917 MMT episodes) from 1996 to 2006 met study inclusion criteria. The primary outcome was sustained successful taper, defined as a daily dose ≤5 mg per day in the final week of the treatment episode and no treatment re-entry, opioid-related hospitalization or mortality within 18 months following episode completion. The overall rate of sustained success was 13% among episodes meeting inclusion criteria (646 of 4917), 4.4% (646 of 14 602) among all episodes initiating a taper and 2.5% (646 of 25 545) among all completed episodes in the data set. The results of our multivariate logistic regression analyses suggested that longer tapers had substantially higher odds of success [12-52 weeks versus 52 weeks versus <12 weeks: OR: 6.68; 95% CI: 5.13-8.70], regardless of how early in the treatment episode the taper was initiated, and a more gradual, stepped tapering schedule, with dose decreases scheduled in only 25-50% of the weeks of the taper, provided the highest odds of sustained success (versus <25%: OR: 1.61; 95% CI: 1.22-2.14). The majority of patients attempting to taper from methadone maintenance treatment will not succeed. Success is enhanced by gradual dose reductions interspersed with periods of stabilization. These results can inform the development of a more refined guideline for future clinical practice. © 2012 The Authors, Addiction © 2012 Society for the Study of Addiction.

  5. THE EFFECT OF TAPERING PERIOD ON PLASMA PRO-INFLAMMATORY CYTOKINE LEVELS AND PERFORMANCE IN ELITE MALE CYCLISTS

    Directory of Open Access Journals (Sweden)

    Peter M. Tiidus

    2009-12-01

    Full Text Available The aim of this study was to investigate the effect of two different tapering period lengths on the concentration of plasma interleukin- 6 (IL-6, interleukin (IL-1β and tumor necrosis factor-? (TNF-α and performance in elite male cyclists. To this end, after completing 8 weeks progressive endurance exercise, twenty four high-level endurance cyclists were randomly assigned to one of two groups: a control group of cyclists (n = 12 continued performing progressive weekly training volume for 3 weeks while a taper group of cyclists (n = 12 proceeded with a 50% reduction in weekly training volume relative to the control group. A simulated 40 min time trial (40TT performance ride was used as the criterion index of performance before and after the tapering period to evaluate the physiological and performance effects of each protocol. Blood samples were collected immediately post-40TT from all participants at the beginning of week 1, and the end of weeks 4, 8, 9 and 11. IL-1β, IL-6 and TNFα were assayed using a standard commercial ELISA kits (Quantikine; R & D Systems, Minneapolis, MN. The mean time to complete the 40TT in the taper group decreased significantly (p < 0.01 after both 1 and 3 weeks with reduced training volume relative to the control group. There were significant reductions in (p < 0.001 IL-1β, IL-6 and TNFα concentrations in the taper group relative to the control group at the end of the 3 week tapering period, but not at the end of the 1 week tapering period. These results demonstrate that both a 1 and a 3 week taper period will result in improved physical performance in trained cyclists but only a 3 week taper period will result in attenuation of post-exercise pro- inflammatory cytokines when compared to those continuing a more intense training regimen

  6. Quantum beams

    International Nuclear Information System (INIS)

    Uesaka, Mitsuru

    2003-01-01

    Present state and future prospect are described on quantum beams for medical use. Efforts for compactness of linac for advanced cancer therapy have brought about the production of machines like Accuray's CyberKnife and TOMOTHERAPY (Tomo Therapy Inc.) where the acceleration frequency of X-band (9-11 GHz) is used. For cervical vein angiography by the X-band linac, a compact hard X-ray source is developed which is based on the (reverse) Compton scattering through laser-electron collision. More intense beam and laser are necessary at present. A compact machine generating the particle beam of 10 MeV-1 GeV (laser-plasma accelerator) for cancer therapy is also developed using the recent compression technique (chirped-pulse amplification) to generate laser of >10 TW. Tokyo University is studying for the electron beam with energy of GeV order, for the laser-based synchrotron X-ray, and for imaging by the short pulse ion beam. Development of advanced compact accelerators is globally attempted. In Japan, a virtual laboratory by National Institute of Radiological Sciences (NIRS), a working group of universities and research facilities through the Ministry of Education, Culture, Sports, Science and Technology, started in 2001 for practical manufacturing of the above-mentioned machines for cancer therapy and for angiography. Virtual Factory (Inc.), a business venture, is to be stood in future. (N.I.)

  7. Electron beam propagation in the ion-focused and resistive regimes

    International Nuclear Information System (INIS)

    Hubbard, R.F.; Lampe, M.; Fernsler, R.; Slinker, S.P.

    1993-01-01

    Pinched propagation of intense relativistic electron beams occurs in several distinct pressure regimes. In low density gases (∼ 1-100 mtorr), the beam propagates in the ion-focused regime (IFR). The beam ionizes the neutral gas, and plasma electrons are ejected, leaving behind a positive ion column which pinches the beam electrostatically. At gas densities near 1 atm, the beam-generated plasma is resistive and the pinch effect is provided by the self-magnetic field of the beam. Beam transport experiments in both regimes have been performed on the Advanced Test Accelerator (ATA) at Lawrence Livermore National Lab. and on SuperIBEX at the Naval Research Lab. IFR methods have been employed in both experiments to transport the beam prior to injection into the air and to introduce a head-to-tail taper in the beam radius. IFR simulations have shown how the resulting beam radius and emittance profiles are influenced by gas density, chamber dimensions and entrance and exit foils. Beam propagation in dense gas is subject to disruption by the resistive hose instability. However, both experiments and simulations have shown that the emittance variation introduced by IFR transport can substantially reduce the growth of the hose instability. Both experiments have also propagated beams in reduced-density channels. Simulations predict that the channel may in some cases produce a moderate stabilizing and tracking effect arising from plasma currents flowing at the edge of the channel

  8. BEAM-BEAM SIMULATIONS FOR DOUBLE-GAUSSIAN BEAMS.

    Energy Technology Data Exchange (ETDEWEB)

    MONTAG, C.; MALITSKY, N.; BEN-ZVI, I.; LITVINENKO, V.

    2005-05-16

    Electron cooling together with intra-beam scattering results in a transverse distribution that can best be described by a sum of two gaussians, one for the high-density core and one for the tails of the distribution. Simulation studies are being performed to understand the beam-beam interaction of these double-gaussian beams. Here we report the effect of low-frequency random tune modulations on diffusion in double-gaussian beams and compare the effects to those in beam-beam interactions with regular gaussian beams and identical tune shift parameters.

  9. BEAM-BEAM SIMULATIONS FOR DOUBLE-GAUSSIAN BEAMS

    International Nuclear Information System (INIS)

    MONTAG, C.; MALITSKY, N.; BEN-ZVI, I.; LITVINENKO, V.

    2005-01-01

    Electron cooling together with intra-beam scattering results in a transverse distribution that can best be described by a sum of two gaussians, one for the high-density core and one for the tails of the distribution. Simulation studies are being performed to understand the beam-beam interaction of these double-gaussian beams. Here we report the effect of loW--frequency random tune modulations on diffusion in double-gaussian beams and compare the effects to those in beam-beam interactions with regular gaussian beams and identical tune shift parameters

  10. Beam-Beam Simulations for Double-Gaussian Beams

    CERN Document Server

    Montag, Christoph; Litvinenko, Vladimir N; Malitsky, Nikolay

    2005-01-01

    Electron cooling together with intra-beam scattering results in a transverse distribution that can best be described by a sum of two Gaussians, one for the high-density core and one for the tails of the distribution. Simulation studies are being performed to understand the beam-beam interaction of these double-Gaussian beams. Here we report the effect of low-frequency random tune modulations on diffusion in double-Gaussian beams and compare the effects to those in beam-beam interactions with regular Gaussian beams and identical tuneshift parameters.

  11. Effect of cyclic torsional preloading on cyclic fatigue resistance of ProTaper Next and Mtwo nickel–titanium instruments

    Directory of Open Access Journals (Sweden)

    Eugenio Pedullà

    2015-06-01

    Conclusions: Torsional preloads reduced the cyclic fatigue resistance of M-wire and conventional (as ProTaper Next and Mtwo NiTi rotary instruments except for Mtwo with 25% or 50% of torsional preloading.

  12. Circadian rest-activity rhythms during benzodiazepine tapering covered by melatonin versus placebo add-on

    DEFF Research Database (Denmark)

    Baandrup, Lone; Fasmer, Ole Bernt; Glenthøj, Birte Yding

    2016-01-01

    -term usage. Melatonin, a naturally occurring nocturnal hormone, has the potential to stabilize disrupted circadian rhythmicity. Our aim was to investigate how prolonged-release melatonin affects rest-activity patterns in medicated patients with severe mental illness and if benzodiazepine dose reduction...... is associated with changes in circadian rhythm parameters. METHOD: Data were derived from a randomized, double-blinded clinical trial with 24 weeks follow-up. Participants were randomized to add-on treatment with prolonged-release melatonin (2 mg) or matching placebo, and usual benzodiazepine dosage...... was gradually tapered. Here we report the results of 72 h of actigraphic assessment of activity-rest cycles performed pre and post tapering. Changes in rest-activity rhythm parameters between the melatonin and placebo group were analyzed using the univariate general linear model. Change in activity counts per 6...

  13. Canal Centring Ability of ProTaper and Mtwo Rotary Systems in Curved Canals

    Directory of Open Access Journals (Sweden)

    Turkaydin Dilek Erbay

    2014-07-01

    Full Text Available The purpose of this investigation was to compare centring ratio of ProTaper and Mtwo rotary systems. 60 mandibular molar teeth which had 25, 30 and 35 degree curvature in mesio-buccal root canal were used. Group 1 had 25°, Group 2 had 30°, and Group 3 had 35° curvatures. The roots were sectioned horizontally at 2 mm away from the apex. The apical region was then observed under a stereo-microscope. In each group, teeth were instrumented using ProTaper and Mtwo systems. After canal preparation, digital images of apical part of canals were taken. These images were then superimposed by using Adobe Photoshop CS2 programme. The data were analyzed using ANOVA and Student’s t-test.

  14. Simplified method for calculating taper winding's induction coefficient matrix of pulse transformer

    International Nuclear Information System (INIS)

    Li Mingjia; Kang Qiang; Xin Jiaqi

    2008-01-01

    The calculation of the voltage distribution of pulse transformer's taper winding with more than 4000 turns is difficult, for the workload of calculating induction coefficient matrix is very heavy. In order to reduce the workload, the characteristics of the induction coefficient matrix were studied. The results show that the self-induction coefficient of the middle turns of the taper winding increase linearly except for the end turns and the mutual induction coefficient decrease rapidly with the inturn-distance increasing. A simplified method for the simulation of multi-turns tape winding is brought forward, which can reduce the calculation steps from n(n+1)/2 to 2n + 25, where n is the turns of the winding. (authors)

  15. A tapered serpentine flow field for the anode of micro direct methanol fuel cells

    Science.gov (United States)

    Zhang, Yufeng; Zhang, Peng; Yuan, Zhenyu; He, Hong; Zhao, Youran; Liu, Xiaowei

    2011-03-01

    We develop a self-breathing micro direct methanol fuel cell (μDMFC) characterized by a new anode structure with tapered single serpentine flow fields to improve cell performance. Compared with the conventional single serpentine flow field, this new design enhances the methanol mass transport efficiency and the exhaust resultant (CO2) rate due to the increasing pressure difference between adjacent flow channels. The μDMFCs with two single serpentine flow fields are fabricated using silicon-based micro-electro-mechanical systems (MEMS) technologies and are tested at room temperature. The experimental results reveal that the new tapered single serpentine flow field exhibits a significantly higher peak power density than that of the conventional flow field, demonstrating a substantial increase of 17.9% in mass transport coefficients.

  16. Total Hip Arthroplasty Using a Polished Tapered Cemented Stem in Hereditary Multiple Exostosis

    Directory of Open Access Journals (Sweden)

    Akio Kanda

    2016-01-01

    Full Text Available A 61-year-old Japanese man underwent right total hip arthroplasty for hereditary multiple exostosis. At first presentation, he had suffered from coxalgia for a long time. On radiographic images, there was a gigantic femoral head, increased shaft angle, and large diameter of the femoral neck. He had also developed coxarthrosis and severe pain of the hip joint. The transformation of the proximal femur bone causes difficulty in setting a cementless total hip prosthesis. Therefore, total hip arthroplasty using a cemented polished tapered stem was performed via a direct lateral approach. Using a cemented polished tapered stem allowed us to deal with the femoral bone transformation and bone substance defectiveness due to exostosis and also minimized the invasiveness of the operation.

  17. Graphene-Tapered ZnO Nanorods Array as a Flexible Antireflection Layer

    Directory of Open Access Journals (Sweden)

    Taeseup Song

    2015-01-01

    Full Text Available Flexible solar cells have drawn a great deal of attention due to their various advantages including deformable and wearable characteristics. In the solar cells, the antireflection layer plays an important role in the improvement in the conversion efficiency by increasing the light transmission and suppressing the Fresnel refraction. For the successful implantation of the antireflection layer into the flexible solar cells, the flexible mechanical property of the antireflection layer is also necessary. However, the study on flexible antireflection layer for the flexible solar cells or optoelectronics is still lacking. In this study, we report the graphene-tapered ZnO nanorods array as a flexible antireflection layer for the application in flexible solar cells. Flexible two-dimensional graphene sheet and the tapered morphology of ZnO nanorods enable conformal coverage on the flexible substrate with curved surface and significant improvements in antireflection properties, respectively.

  18. Tapering of Polymer Optical Fibers for Compound Parabolic Concentrator Fiber Tip Fabrication

    DEFF Research Database (Denmark)

    Hassan, Hafeez Ul; Fasano, Andrea; Nielsen, Kristian

    2015-01-01

    We propose a process for Polymer Optical Fiber (POF) Compound Parabolic Compound (CPC) tip manufacturing using a heat and pull fiber tapering technique. The POF, locally heated above its glass transition temperature, is parabolically tapered down in diameter, after which it is cut to the desired...... output diameter and finally polished to obtain the special CPC tip. The physical mechanism responsible for giving a CPC shape to the POF tip is also investigated. The fabrication process is shown to be sensitive to several manufacturing parameters, such as temperature of the heat source, thermal flux...... from the heat source, and heating time. We further consider the influence of the heating time latter parameter on the geometry of the obtained CPC fiber tips...

  19. High-resolution optical spectroscopy using multimode interference in a compact tapered fibre.

    Science.gov (United States)

    Wan, Noel H; Meng, Fan; Schröder, Tim; Shiue, Ren-Jye; Chen, Edward H; Englund, Dirk

    2015-07-23

    Optical spectroscopy is a fundamental tool in numerous areas of science and technology. Much effort has focused on miniaturizing spectrometers, but thus far at the cost of spectral resolution and broad operating range. Here we describe a compact spectrometer that achieves both high spectral resolution and broad bandwidth. The device relies on imaging multimode interference from leaky modes along a multimode tapered optical fibre, resulting in spectrally distinguishable spatial patterns over a wide range of wavelengths from 500 to 1,600 nm. This tapered fibre multimode interference spectrometer achieves a spectral resolution down to 40 pm in the visible spectrum and 10 pm in the near-infrared spectrum (corresponding to resolving powers of 10(4)-10(5)). Multimode interference spectroscopy is suitable in a variety of device geometries, including planar waveguides in a broad range of transparent materials.

  20. Some flow characteristics of conventional and tapered high-pressure-drop simulated seals

    Science.gov (United States)

    Hendricks, R. C.

    1979-01-01

    The leak rates through shaft seals with large pressure drops were simulated using gaseous hydrogen, or nitrogen flowing through an annulus with a nonrotating centerbody. The flows were choked. For concentric or eccentric position of the rotor and parallel or convergent tapered flow passages, data and analysis revealed that mass flux or leak rate can be determined from a relation whose normalizing parameters depend on the thermodynamic critical constants of the working fluid and an average flow area expressed in terms of the inlet and exit cross-sectional areas. Using these normalized relations, the flow data for parallel and three convergent, tapered, shaft-seal configurations are in good agreement. Generalization to any simple gas or gas mixtures is implied and demonstrated in part.

  1. Some flow characteristics of conventional and tapered high pressure drop simulated seals

    Science.gov (United States)

    Hendricks, R. C.

    1979-01-01

    The leak rates through shaft seals with large pressure drops were simulated using gaseous hydrogen, or nitrogen flowing through an annulus with a nonrotating centerbody. The flows were choked. For concentric or eccentric position of the rotor and parallel or convergent tapered flow passages, data and analysis revealed that mass flux or leak rate can be determined from a relation whose normalizing parameters depend on the thermodynamic critical constants of the working fluid and an average flow area expressed in terms of the inlet and exit cross-sectional areas. Using these normalized relations, the flow data for parallel and three convergent tapered shaft seal configurations are in good agreement. Generalization to any simple gas or gas mixture is implied and demonstrated.

  2. Analysis of the coupling efficiency of a tapered space receiver with a calculus mathematical model

    Science.gov (United States)

    Hu, Qinggui; Mu, Yining

    2018-03-01

    We establish a calculus mathematical model to study the coupling characteristics of tapered optical fibers in a space communications system, and obtained the coupling efficiency equation. Then, using MATLAB software, the solution was calculated. After this, the sample was produced by the mature flame-brush technique. The experiment was then performed, and the results were in accordance with the theoretical analysis. This shows that the theoretical analysis was correct and indicates that a tapered structure could improve its tolerance with misalignment. Project supported by The National Natural Science Foundation of China (grant no. 61275080); 2017 Jilin Province Science and Technology Development Plan-Science and Technology Innovation Fund for Small and Medium Enterprises (20170308029HJ); ‘thirteen five’ science and technology research project of the Department of Education of Jilin 2016 (16JK009).

  3. Surface plasmon resonance sensors based on uniform-waist tapered fibers in a reflective configuration

    Science.gov (United States)

    Esteban, Óscar; Díaz-Herrera, Natalia; Navarrete, María-Cruz; González-Cano, Agustín

    2006-10-01

    We present a configuration for surface plasmon resonance sensors based on uniform-waist tapered optical fibers and reflective elements. Once the fiber is tapered fulfilling the adiabatic criterion, a multilayer including a metallic medium is asymmetrically deposited on the uniform waist of the fiber. This feature provides the resonant excitation of multiple surface plasma waves. In addition, a mirror is produced at the fiber tip by a chemical Tollens reaction. In this way, the sensor operates in a reflective mode, more convenient for dip probes. When these sensors are spectrally interrogated, a high sensitivity of 10-4 refractive index units per nanometer is attained. These devices can be advantageously used for any kind of chemical sensing and biosensing.

  4. Large-aperture CCD x-ray detector for protein crystallography using a fiber-optic taper

    Science.gov (United States)

    Strauss, Michael G.; Westbrook, Edwin M.; Naday, Istvan; Coleman, T. A.; Westbrook, Mary L.; Travis, D. J.; Sweet, Robert M.; Pflugrath, J. W.; Stanton, Martin J.

    1991-07-01

    A detector with a 114 mm aperture, based on a charge-coupled device (CCD), has been designed for x-ray diffraction studies in protein crystallography. The detector was tested on a beamline of the National Synchrotron Light Source at Brookhaven National Laboratory with a beam intensity greater than 10(superscript 9) x-ray photons/s. A fiber-optic taper, an image intensifier, and a lens demagnify, intensify, and focus the image onto a CCD having 512 X 512 pixels. A detective quantum efficiency (DQE) of 0.36 was obtained by evaluating the statistical uncertainty in the detector output. The dynamic range of a 4 X 4 pixel resolution element, comparable in size to a diffraction peak, was 10 (superscript 4). The point-spread function shows FWHM resolution of approximately 1 pixel, where a pixel on the detector face is 160 micrometers . A complete data set, consisting of forty-five 1 degree(s) rotation frames, was obtained in just 36 s of x-ray exposure to a crystal of chicken egg-white lysozyme. In a separate experiment, a lysozyme data set consisting of 495 0.1 degree(s) frames, was processed by the MADNES data reduction program, yielding symmetry R-factors for the data of 3.2- 3.5%. Diffraction images from crystals of the myosin S1 head (a equals 275 angstroms) were also recorded. The Bragg spots, only 5 pixels apart, were resolved but were not sufficiently separated to process these data. Changes in the detector design which will improve the DQE and spatial resolution are outlined. The overall performance showed that this type of detector is well suited for x-ray scattering investigations with synchrotron sources.

  5. Clinical effect of a manual toothbrush with tapered filaments on dental plaque and gingivitis reduction.

    Science.gov (United States)

    Ni, Longxing; Tang, Rongying; He, Tao; Chang, Jinlan; Li, Jiahui; Li, Sarah; Ccahuana-Vasquez, Renzo Alberto; Cheng, Richard; Grender, Julie

    2017-10-01

    To evaluate the anti-plaque efficacy (Study 1) and the anti-gingivitis efficacy (Study 2) of a manual toothbrush with tapered bristles compared to marketed control manual toothbrushes. Studies 1 and 2 were independent, randomized and controlled, single-center, examiner-blind clinical trials in generally healthy adults. Study 1 included a 2-day acclimation period, followed by a 5-day twice daily toothbrushing test phase with the assigned brush. Baseline and Day 5 pre- and post-brushing plaque levels were assessed via Turesky Modified Quigley-Hein Plaque Index (TMQHPI). In Study 2, subjects with existing gingivitis brushed with their assigned toothbrush twice daily for 4 weeks. Gingivitis was measured using the Mazza Modification of the Papillary Bleeding Index at Baseline and Weeks 2 and 4. In both trials, subjects were randomly assigned to either the manual toothbrush with tapered bristles (Oral-B Super Thin Indicator toothbrush, OM159) or the marketed control (Study 1: Oral-B Complete Clean & Sensitive toothbrush; Study 2: Crest Pro-Health Complete 7 Brush 35 toothbrush) for use with a regular fluoridated dentifrice. 40 (Study 1) and 63 (Study 2) subjects were randomized in each trial. In Study 1, both the tapered bristle and marketed control brushes provided significant (Ptoothbrush group showed 8.6% less gingivitis (P= 0.0017) and 33.4% fewer bleeding sites (P= 0.0030) versus the control brush. All toothbrushes were well-tolerated. Twice daily customary use of a manual toothbrush with tapered bristles provided clinically meaningful plaque and gingivitis reduction benefits.

  6. Early Experience with a Short, Tapered Titanium Porous Plasma Sprayed Stem with Updated Design.

    Science.gov (United States)

    Lombardi, Adolph V; Manocchio, Antonio G; Berend, Keith R; Morris, Michael J; Adams, Joanne B

    2018-03-12

    Short stem femoral components in primary total hip arthroplasty (THA) have increased in popularity since the advent of minimally invasive surgical techniques. The concept of a short stem is particularly compatible with tapered designs where the goal is to offload forces proximally in the femur. The purpose of this retrospective review was to review our early experience with a short, tapered titanium femoral component with updated design features. Beginning in November 2011 through February 2012, 92 consented patients (93 hips), at a single center, were treated with primary cementless THA using a short stem, tapered femoral component (Taperloc® Complete Microplasty; Zimmer Biomet, Warsaw, Indiana) and were available for review with a minimum two-year follow-up. Mean patient age at surgery was 63.2 years and body mass index (BMI) was 30.8 kg/m2. Mean stem length used was 110.3mm (range, 95-125). Mean follow-up was 4.5 years (2-6). Harris hip scores improved from 52.5 preoperatively to 84.7 at most recent. One stem was revised the same day for periprosthetic fracture. One patient with early infection was treated with single-stage exchange followed by recurrence that was treated successfully with two-stage exchange. A non-healing wound in one patient was treated with incision and debridement. Radiographic assessment demonstrated no evidence of loosening, osteolysis, distal hypertrophy, or pedestal formation in any hip, and all components appeared well fixed and in appropriate alignment. In this series of patients treated with primary THA using a short, tapered titanium porous plasma-sprayed femoral component with updated design features, good results were achieved with a low incidence of complications and revision. No aseptic loosening or osteolysis has occurred. Radiographic assessment was excellent for all patients.

  7. Microbial leakage through the implant-abutment interface of Morse taper implants in vitro.

    Science.gov (United States)

    Aloise, João Pedro; Curcio, Ricardo; Laporta, Marcia Zorello; Rossi, Liliane; da Silva, Adriana Madeira Alvares; Rapoport, Abrão

    2010-03-01

    The aim of this study was to determine and compare the frequency of bacterial leakage of Streptococcus sanguinis biotype II along the implant-abutment interface between two systems of morse taper dental implants. Different methods of activation of the taper abutments were used: tapped-in (Bicon) and screwed-in (Ankylos). Twenty sterile assemblies were used and attached, 10 Bicon and 10 Ankylos implants, according to manufacturers' specifications. They were then totally immersed within 20 test tubes containing a sterile nutrient solution brain-heart infusion (BHI). The internal part of the 20 implants was previously inoculated with 0.1 microl of S. sanguinis II (ATCC 10557) and then connected to the respective abutments. The assemblies were incubated under anaerobic conditions for 14 days in an autoclave at 37 degrees C. They were monitored daily for solution cloudiness resultant from microbial leakage on the interface of the assemblies. For statistical analysis, the Fisher test was applied and significance was assigned at the 5% level. There was solution cloudiness, indicating the finding of bacterial growth inside two Bicon assemblies and two Ankylos assemblies 48 h after incubation. Microbial leakage was further substantiated by testing the suspension for the presence of Streptococcus sp. None of the sterility controls were contaminated. The frequency of bacterial leakage along the implant-abutment interface, with the two different morse taper implant systems, was 20% of the assemblies of each system. There were no statistical differences between them. Irrespective of which of the two morse taper implant connection systems of activation was analyzed, tapped-in (Bicon) or screwed-in (Ankylos), this in vitro experiment showed bacterial leakage along the implant-abutment interface.

  8. Fretting and Corrosion Damage in Taper Adapter Sleeves for Ceramic Heads: A Retrieval Study.

    Science.gov (United States)

    MacDonald, Daniel W; Chen, Antonia F; Lee, Gwo-Chin; Klein, Gregg R; Mont, Michael A; Kurtz, Steven M; Cates, Harold E; Kraay, Matthew J; Rimnac, Clare M

    2017-09-01

    During revision surgery with a well-fixed stem, a titanium sleeve can be used in conjunction with a ceramic head to achieve better stress distribution across the taper surface. In vitro testing suggests that corrosion is not a concern in sleeved ceramic heads; however, little is known about the in vivo fretting corrosion of the sleeves. The purpose of this study was to investigate fretting corrosion in sleeved ceramic heads in retrieved total hip arthroplasties. Thirty-seven sleeved ceramic heads were collected during revision. The femoral heads and sleeves were implanted 0.0-3.3 years. The implants were revised predominantly for instability, infection, and loosening. Fifty percent of the retrievals were implanted during a primary surgery. Fretting corrosion was assessed using the Goldberg-Higgs semiquantitative scoring system. Mild-to-moderate fretting corrosion scores (score = 2-3) were observed in 92% of internal tapers, 19% of external tapers, and 78% of the stems. Severe fretting corrosion was observed in 1 stem trunnion that was previously retained during revision surgery and none of the retrieved sleeves. There was no difference in corrosion damage of sleeves used in primary or revision surgery. The fretting corrosion scores in this study were predominantly mild and lower than reported fretting scores of cobalt-chrome heads in metal-on-polyethylene bearings. Although intended for use in revisions, we found that the short-term in vivo corrosion behavior of the sleeves was similar in both primary and revision surgery applications. From an in vivo corrosion perspective, sleeves are a reasonable solution for restoring the stem taper during revision surgery. Copyright © 2017. Published by Elsevier Inc.

  9. ELASTIC AND SAFETY CLUTCH WITH RADIAL TAPERED ROLLER AND METALLIC ELASTIC ELEMENTS AXIALLY ARRANGED

    OpenAIRE

    STROE Ioan

    2014-01-01

    The paper presents a new type of clutch named `Elastic and Safety Clutch` that can accomplish the functions of the elastic and those of the safety clutches, but it is not a combined clutch. The proposed clutch is an elastic and safety clutch with metallic intermediate elements. The paper presents the elastic and safety clutch with radial tapered roller and metallic elastic elements axially arranged. The design and verification computing relations of the elastic and safety...

  10. A Study of Two Dimensional Tapered Periodic Edge Treatments to Reduce Wideband Edge Diffraction

    Science.gov (United States)

    1993-12-01

    Possible. -’ TEM Horn Antenna ’%/ \\ Parabolic Dish Antenna Trailing Edge Diffraction Reduction Figure 2. Possible Uses of Geometrical Tapers. This...wedge in 2D . This antenna was resistively loaded such that the impedance of the source was slowly matched to the impedance of free space. This antenna ...configuration was considered to be infinite and constant in the i direction. For both FDTD and MoM numerical techniques, 2D analysis was much faster and

  11. Refractive index sensor based on an abrupt taper Michelson interferometer in a single-mode fiber.

    Science.gov (United States)

    Tian, Zhaobing; Yam, Scott S-H; Loock, Hans-Peter

    2008-05-15

    A simple refractive index sensor based on a Michelson interferometer in a single-mode fiber is constructed and demonstrated. The sensor consists of a single symmetrically abrupt taper region in a short piece of single-mode fiber that is terminated by approximately 500 nm thick gold coating. The sensitivity of the new sensor is similar to that of a long-period-grating-type sensor, and its ease of fabrication offers a low-cost alternative to current sensing applications.

  12. Energy partitioning and impulse dispersion in the decorated, tapered, strongly nonlinear granular alignment: A system with many potential applications

    Science.gov (United States)

    Doney, Robert L.; Agui, Juan H.; Sen, Surajit

    2009-09-01

    Rapid absorption of impulses using light-weight, small, reusable systems is a challenging problem. An axially aligned set of progressively shrinking elastic spheres, a "tapered chain," has been shown to be a versatile and scalable shock absorber in earlier simulational, theoretical, and experimental works by several authors. We have recently shown (see R. L. Doney and S. Sen, Phys. Rev. Lett. 97, 155502 (2006)) that the shock absorption ability of a tapered chain can be dramatically enhanced by placing small interstitial grains between the regular grains in the tapered chain systems. Here we focus on a detailed study of the problem introduced in the above mentioned letter, present extensive dynamical simulations using parameters for a titanium-aluminum-vanadium alloy Ti6Al4V, derive attendant hard-sphere analyses based formulae to describe energy dispersion, and finally discuss some preliminary experimental results using systems with chrome spheres and small Nitinol interstitial grains to present the underlying nonlinear dynamics of this so-called decorated tapered granular alignment. We are specifically interested in small systems, comprised of several grains. This is because in real applications, mass and volume occupied must inevitably be minimized. Our conclusion is that the decorated tapered chain offers enhanced energy dispersion by locking in much of the input energy in the grains of the tapered chain rather than in the small interstitial grains. Thus, the present study offers insights into how the shock absorption capabilities of these systems can be pushed even further by improving energy absorption capabilities of the larger grains in the tapered chains. We envision that these scalable, decorated tapered chains may be used as shock absorbing components in body armor, armored vehicles, building applications and in perhaps even in applications in rehabilitation science.

  13. High-power free-electron laser amplifier using a scalloped electron beam and a two-stage wiggler

    Directory of Open Access Journals (Sweden)

    D. C. Nguyen

    2006-05-01

    Full Text Available High-power free-electron laser (FEL amplifiers present many practical design and construction problems. One such problem is possible damage to any optical beam control elements beyond the wiggler. The ability to increase the optical beam’s divergence angle after the wiggler, thereby reducing the intensity on the first optical element, is important to minimize such damage. One proposal to accomplish this optical beam spreading is to pinch the electron beam thereby focusing the radiation as well. In this paper, we analyze an approach that relies on the natural betatron motion to pinch the electron beam near the end of the wiggler. We also consider a step-tapered, two-stage wiggler to enhance the efficiency. The combination of a pinched electron beam and step-taper wiggler leads to additional optical guiding of the optical beam. This novel configuration is studied in simulation using the MEDUSA code. For a representative set of beam and wiggler parameters, we discuss (i the effect of the scalloped beam on the interaction in the FEL and on the focusing and propagation of the radiation, and (ii the efficiency enhancement in the two-stage wiggler.

  14. Point mobility of a cylindrical plate incorporating a tapered hole of power-law profile.

    Science.gov (United States)

    O'Boy, Daniel J; Bowyer, Elizabeth P; Krylov, Victor V

    2011-06-01

    The paper describes the results of experimental measurements of point mobility carried out on circular plates containing tapered holes of quadratic power-law profile with attached damping layers. The obtained results are compared to the developed numerical model, as a means of validation. The profiles of the tapered hole in the plates are designed to replicate near zero reflection of quasi-plane waves from a tapered hole in geometrical acoustics approximation, also known as acoustic black hole effect. The driving point mobility measurements are provided, showing a comparison of the results for a constant thickness circular plate, a constant thickness plate with a layer of damping film applied and a plate with a quadratic power-law profile machined into the center, which is tested with a thin layer of elastic damping material attached. The results indicate a substantial suppression of resonant peaks, agreeing with a numerical model, which is based on the analytical solution available for the vibration of a plate with a central quadratic power-law profile. The paper contains results for the case of free boundary conditions on all edges of the plates, with emphasis placed on the predictions of resonant frequencies and the amplitudes of vibration and loss factor. © 2011 Acoustical Society of America

  15. Geometric and dimensional characteristics of simulated curved canals prepared with proTaper instruments

    Science.gov (United States)

    MARTINS, Renata de Castro; BAHIA, Maria Guiomar de Azevedo; BUONO, Vicente Tadeu Lopes

    2010-01-01

    Objective This study identified which regions of ProTaper instruments work during curved root canal instrumentation. Material and methods Twelve ProTaper instruments of each type, S1, S2, F1, and F2, were assessed morphometrically by measuring tip angle, tip length, tip diameter, length of each pitch along the cutting blades, and instrument diameter at each millimeter from the tip. Curved canals in resin blocks were explored with manual stainless steel files and prepared with ProTaper instruments until the apical end following four distinct sequences of instrumentation: S1; S1 and S2; S1, S2, and F1; S1, S2, F1, and F2. Image analysis was employed for measuring canal diameters. The diameters of the canals and diameters of the instruments were compared. Data were analyzed by one-way ANOVA and Tukey’s test. Results No statistically significant difference was found between the canals and instrument diameters (p>0.05). The largest diameters in the end-point of the instrumented canals were obtained with F1 and F2 instruments and in the initial and middle thirds with S1 and S2 instruments. Conclusions All instruments worked at the tip and along their cutting blades, being susceptible to fail by torsion, fatigue, or the combination of these two mechanisms. PMID:20379681

  16. Thermal and stress analyses in thermoelectric generator with tapered and rectangular pin configurations

    International Nuclear Information System (INIS)

    Yilbas, Bekir Sami; Akhtar, S.S.; Sahin, A.Z.

    2016-01-01

    Thermal stress developed in thermoelectric generators is critical for long service applications. High temperature gradients, due to a large temperature difference across the junctions, causes excessive stress levels developed in the device pins and electrodes at the interfaces. In the present study, a thermoelectric generator with horizontal pin configuration is considered and thermal stress analysis in the device is presented. Ceramic wafer is considered to resemble the high temperature plate and copper electrodes are introduced at the pin junctions to reduce the electrical resistance between the pins and the high and low temperature junction plates during the operation. Finite element code is used to simulate temperature and stress fields in the thermoelectric generator. In the simulations, convection and radiation losses from the thermoelectric pins are considered and bismuth telluride pin material with and without tapering is incorporated. It is found that von Mises stress attains high values at the interface between the hot and cold junctions and the copper electrodes. Thermal stress developed in tapered pin configuration attains lower values than that of rectangular pin cross-section. - Highlights: • Different cold junction temperatures improves thermoelectric generator performance. • von Mises stress remains high across copper electrodes and hot junction ceramics. • von Mises stress reduces along pin length towards cold junction. • Pin tapering lowers stress levels in thermoelectric generator.

  17. Seismic stability analyses of reinforced tapered landfill cover systems considering seepage forces.

    Science.gov (United States)

    Khoshand, Afshin; Fathi, Ali; Zoghi, Milad; Kamalan, Hamidreza

    2018-04-01

    One of the most common and economical methods for waste disposal is landfilling. The landfill cover system is one of the main components of landfills which prevents waste exposure to the environment by creating a barrier between the waste and the surrounding environment. The stability and integrity of the landfill cover system is a fundamental part of the design, construction, and maintenance of landfills. A reinforced tapered landfill cover system can be considered as a practical method for improving its stability; however, the simultaneous effects of seismic and seepage forces in the reinforced tapered landfill cover system have not been studied. The current paper provides a solution based on the limit equilibrium method in order to evaluate the stability of a reinforced tapered landfill cover system under seismic and seepage (both horizontal and parallel seepage force patterns) loading conditions. The proposed analytical approach is applied to different design cases through parametric study and the obtained results are compared to those derived from literature. Parametric study is performed to illustrate the sensitivity of the safety factor (FS) to the different design parameters. The obtained results reveal that parameters which describe the geometry have limited effects on the stability of the landfill cover system in comparison to the rest of the studied design parameters. Moreover, the comparisons between the derived results and available methods demonstrate good agreement between obtained findings with those reported in the literature.

  18. Influence of pitch, twist, and taper on a blade`s performance loss due to roughness

    Energy Technology Data Exchange (ETDEWEB)

    Tangler, J.L. [National Renewable Energy Lab., Golden, CO (United States)

    1996-12-31

    The purpose of this study was to determine the influence of blade geometric parameters such as pitch, twist, and taper on a blade`s sensitivity to leading edge roughness. The approach began with an evaluation of available test data of performance degradation due to roughness effects for several rotors. In addition to airfoil geometry, this evaluation suggested that a rotor`s sensitivity to roughness was also influenced by the blade geometric parameters. Parametric studies were conducted using the PROP computer code with wind-tunnel airfoil characteristics for smooth and rough surface conditions to quantify the performance loss due to roughness for tapered and twisted blades relative to a constant-chord, non-twisted blade at several blade pitch angles. The results indicate that a constant-chord, non-twisted blade pitched toward stall will have the greatest losses due to roughness. The use of twist, taper, and positive blade pitch angles all help reduce the angle-of-attack distribution along the blade for a given wind speed and the associated performance degradation due to roughness. 8 refs., 6 figs.

  19. Novel Highly Sensitive Protein Sensors Based on Tapered Optical Fibres Modified with Au-Based Nanocoatings

    Directory of Open Access Journals (Sweden)

    Aitor Urrutia

    2016-01-01

    Full Text Available Novel protein sensors based on tapered optical fibres modified with Au coatings deposited using two different procedures are proposed. Au-based coatings are deposited onto a nonadiabatic tapered optical fibre using (i a novel facile method composed of layer-by-layer deposition consisting of polycation (poly(allylamine hydrochloride, PAH and negatively charged SiO2 nanoparticles (NPs followed by the deposition of the charged Au NPs and (ii the sputtering technique. The Au NPs and Au thin film surfaces are then modified with biotin in order to bind streptavidin (SV molecules and detect them. The sensing principle is based on the sensitivity of the transmission spectrum of the device to changes in the refractive index of the coatings induced by the SV binding to the biotin. Both sensors showed high sensitivity to SV, with the lowest measured concentration levels below 2.5 nM. The calculated binding constant for the biotin-SV pair was 2.2×10-11 M−1 when a tapered fibre modified with the LbL method was used, with a limit of detection (LoD of 271 pM. The sensor formed using sputtering had a binding constant of 1.01×10-10 M−1 with a LoD of 806 pM. These new structures and their simple fabrication technique could be used to develop other biosensors.

  20. Influence of pitch, twist, and taper on a blade`s performance loss due to roughness

    Energy Technology Data Exchange (ETDEWEB)

    Tangler, J.L. [National Renewable Energy Laboratory, Golden, Colorado (United States)

    1997-08-01

    The purpose of this study was to determine the influence of blade geometric parameters such as pitch, twist, and taper on a blade`s sensitivity to leading edge roughness. The approach began with an evaluation of available test data of performance degradation due to roughness effects for several rotors. In addition to airfoil geometry, this evaluation suggested that a rotor`s sensitivity to roughness was also influenced by the blade geometric parameters. Parametric studies were conducted using the PROP computer code with wind-tunnel airfoil characteristics for smooth and rough surface conditions to quantify the performance loss due to roughness for tapered and twisted blades relative to a constant-chord, non-twisted blade at several blade pitch angles. The results indicate that a constant-chord, non-twisted blade pitched toward stall will have the greatest losses due to roughness. The use of twist, taper, and positive blade pitch angles all help reduce the angle-of-attack distribution along the blade for a given wind speed and the associated performance degradation due to roughness. (au)

  1. Biomechanical Analysis of Tapered Integrated Screw and Sensitivity Analysis on Abutment Loosening in Dental Implants

    Directory of Open Access Journals (Sweden)

    Milad Farzadi

    2013-02-01

    Full Text Available Background and Aims: Different mechanisms have been developed for connecting abutment to implant. One of the most popular mechanisms is Tapered Integrated Screw (TIS, which is a Tapered Interference Fit (TIF with a screw integrated at the bottom of that. The aim of this study was to investigate the mechanism of TIS and effective factors in employing TIS during design and implementation processes using an analytic method.Materials and Methods: Relevant equations were developed to predict tightening and loosening torques, contactpressure and preloads with and without bone tissue in this analysis. The efficiency is defined as the ratio of the loosening torque to the tightening torque. The effects of the change in elastic modulus and thickness of the bone on operation of this mechanism were investigated.Results: In this study, 14 independent parameters such as taper angle, friction coefficient, abutment and implantgeometry that are effective on performance of TIS mechanism were presented. The role of some factors was shown in the performance of ITI implant using sensitivity analysis.Conclusion: It was shown that friction coefficient, contact length, and implant radius play major roles on tightening and loosening torques and efficiency of the mechanism. Furthermore, the results revealed that the change in the elastic modulus and thickness of the bone influenced the efficiency of the mechanism less than 15%.

  2. Comparison between a position sensitive germanium detector and a taper optics CCD ``FRELON'' camera for diffraction enhanced imaging

    Science.gov (United States)

    Bravin, A.; Fiedler, S.; Coan, P.; Labiche, J.-C.; Ponchut, C.; Peterzol, A.; Thomlinson, W.

    2003-09-01

    Diffraction Enhanced Imaging (DEI) can significantly improve the expressiveness of radiology. The contrast mechanism of DEI, in addition to absorption contrast, exploits the differences in X-ray refraction properties, which are sensed by a perfect crystal placed between the sample and the detector. DEI needs a monochromatic collimated X-ray source, which is available for instance from synchrotrons. The X-ray beam is laminar and the sample is vertically scanned for projection imaging or is rotated for CT. Detectors should match the beam characteristics and should also accomplish the other two main requirements for DEI mammography: high spatial resolution and high Detective Quantum Efficiency (DQE) in a large energy range (20-60 keV). The first permit to exploit the edge contrast enhancement obtained with the DEI technique, for example the improved visualization of microcalcifications in mammographic imaging. The second allows minimizing the dose needed for a radiograph without sacrificing spatial resolution. Apart from this, a dynamic range as good as possible is required (typically from 14 to 16 bits) as well as a high readout speed, which is particularly important for CT. These specifications are difficult to be all condensed in a single detector. At the medical beamline of the ESRF two devices have been utilized for DEI radiography: a linear germanium detector (432 pixels, 350 microns pitch), which had been developed for angiography and cerebral CT and a 2048×2048 CCD camera with taper optics which has been built at the ESRF. The first detector shows an excellent DQE at zero frequency in a large energy range (˜90% from 20 keV up to 50 keV) but limited spatial resolution. In the latter a better compromise for DEI in the 20-30 keV range has been realized: a pixel size of 47 μm and a DQE(0) from 0.5 to 0.6 has been achieved. The performances of the two detectors will be presented here in detail and discussed.

  3. Generation of a cold, intense relativistic electron beam using a magnetized foilless diode

    International Nuclear Information System (INIS)

    Sheffield, R.L.; Montgomery, M.D.; Parker, J.V.; Riepe, K.B.; Singer, S.

    1982-01-01

    An annular electron beam with less than 30 mrad of angular velocity spread, a radius of 1 cm, and a current density exceeding 0.4 MA/cm 2 has been generated with a magnetized foilless diode. The diode current loss is limited to less than a few percent by careful design of the tapered transition region connecting a self-magnetically insulated vacuum transmission line to the externally magnetized foilless diode. Details of the transition section design and operating characteristics of the electron beam generator are given

  4. Beam transport

    International Nuclear Information System (INIS)

    1988-01-01

    The beam diagnostic components for both the transfer and the high-energy beamlines perform well except for some of the scanners whose noise pick-up has become a problem, especially at low beam intensities. This noise pick-up is primarily due to deterioration of the bearings in the scanner. At some locations in the high-energy beamlines, scanners were replaced by harps as the scanners proved to be practically useless for the low-intensity beams required in the experimental areas. The slits in the low-energy beamline, which are not water-cooled, have to be repaired at regular intervals because of vacuum leaks. Overheating causes the ceramic feedthroughs to deteriorate resulting in the vacuum leaks. Water-cooled slits have been ordered to replace the existing slits which will later be used in the beamlines associated with the second injector cyclotron SPC2. The current-measurement system will be slightly modified and should then be much more reliable. 3 figs

  5. K- and L-edge X-ray absorption spectrum calculations of closed-shell carbon, silicon, germanium, and sulfur compounds using damped four-component density functional response theory.

    Science.gov (United States)

    Fransson, Thomas; Burdakova, Daria; Norman, Patrick

    2016-05-21

    X-ray absorption spectra of carbon, silicon, germanium, and sulfur compounds have been investigated by means of damped four-component density functional response theory. It is demonstrated that a reliable description of relativistic effects is obtained at both K- and L-edges. Notably, an excellent agreement with experimental results is obtained for L2,3-spectra-with spin-orbit effects well accounted for-also in cases when the experimental intensity ratio deviates from the statistical one of 2 : 1. The theoretical results are consistent with calculations using standard response theory as well as recently reported real-time propagation methods in time-dependent density functional theory, and the virtues of different approaches are discussed. As compared to silane and silicon tetrachloride, an anomalous error in the absolute energy is reported for the L2,3-spectrum of silicon tetrafluoride, amounting to an additional spectral shift of ∼1 eV. This anomaly is also observed for other exchange-correlation functionals, but it is seen neither at other silicon edges nor at the carbon K-edge of fluorine derivatives of ethene. Considering the series of molecules SiH4-XFX with X = 1, 2, 3, 4, a gradual divergence from interpolated experimental ionization potentials is observed at the level of Kohn-Sham density functional theory (DFT), and to a smaller extent with the use of Hartree-Fock. This anomalous error is thus attributed partly to difficulties in correctly emulating the electronic structure effects imposed by the very electronegative fluorines, and partly due to inconsistencies in the spurious electron self-repulsion in DFT. Substitution with one, or possibly two, fluorine atoms is estimated to yield small enough errors to allow for reliable interpretations and predictions of L2,3-spectra of more complex and extended silicon-based systems.

  6. Influence of NiTi alloy on the root canal shaping capabilities of the ProTaper Universal and ProTaper Gold rotary instrument systems

    Directory of Open Access Journals (Sweden)

    Jussaro Alves DUQUE

    Full Text Available Abstract Objective This study aimed to evaluate the influence of the NiTi wire in Conventional NiTi (ProTaper Universal PTU and Controlled Memory NiTi (ProTaper Gold PTG instrument systems on the quality of root canal preparation. Material and Methods Twelve mandibular molars with separate mesial canals were scanned using a high-definition microcomputed tomography system. The PTU and PTG instruments were used to shape twelve mesial canals each. The canals were scanned after preparation with F2 and F3 instruments of the PTU and PTG systems. The analyzed parameters included the remaining dentin thickness at the apical and cervical levels, root canal volume and untouched canal walls. Data was analyzed for statistical significance by the Friedman and Dunn’s tests. For the comparison of data between groups, the Mann-Whitney test was used. Results In the pre-operative analysis, there were no statistically significant differences between the groups in terms of the area and volume of root canals (P>.05. There was also no statistically significant difference between the systems with respect to root canal volume after use of the F2 and F3 instruments. There was no statistical difference in the dentin thickness at the first apical level between, before and after instrumentation for both systems. At the 3 cervical levels, the PTG maintained centralization of the preparation on the transition between the F2 and F3 instruments, which did not occur with the PTU. Conclusion The Conventional NiTi (PTU and Controlled Memory NiTi (PTG instruments displayed comparable capabilities for shaping the straight mesial root canals of mandibular molars, although the PTG was better than the PTU at maintaining the centralization of the shape in the cervical portion.

  7. Influence of NiTi alloy on the root canal shaping capabilities of the ProTaper Universal and ProTaper Gold rotary instrument systems.

    Science.gov (United States)

    Duque, Jussaro Alves; Vivan, Rodrigo Ricci; Cavenago, Bruno Cavalini; Amoroso-Silva, Pablo Andrés; Bernardes, Ricardo Affonso; Vasconcelos, Bruno Carvalho de; Duarte, Marco Antonio Hungaro

    2017-01-01

    This study aimed to evaluate the influence of the NiTi wire in Conventional NiTi (ProTaper Universal PTU) and Controlled Memory NiTi (ProTaper Gold PTG) instrument systems on the quality of root canal preparation. Twelve mandibular molars with separate mesial canals were scanned using a high-definition microcomputed tomography system. The PTU and PTG instruments were used to shape twelve mesial canals each. The canals were scanned after preparation with F2 and F3 instruments of the PTU and PTG systems. The analyzed parameters included the remaining dentin thickness at the apical and cervical levels, root canal volume and untouched canal walls. Data was analyzed for statistical significance by the Friedman and Dunn's tests. For the comparison of data between groups, the Mann-Whitney test was used. In the pre-operative analysis, there were no statistically significant differences between the groups in terms of the area and volume of root canals (P>.05). There was also no statistically significant difference between the systems with respect to root canal volume after use of the F2 and F3 instruments. There was no statistical difference in the dentin thickness at the first apical level between, before and after instrumentation for both systems. At the 3 cervical levels, the PTG maintained centralization of the preparation on the transition between the F2 and F3 instruments, which did not occur with the PTU. Conclusion The Conventional NiTi (PTU) and Controlled Memory NiTi (PTG) instruments displayed comparable capabilities for shaping the straight mesial root canals of mandibular molars, although the PTG was better than the PTU at maintaining the centralization of the shape in the cervical portion.

  8. Longitudinal impedance of LHC version-1 stripline beam position monitor

    CERN Document Server

    Vos, L

    1997-01-01

    The electrodes in the first version of the LHC beam position monitor are 50 \\W striplines. An enlarged aperture is required to keep the inner face of the electrodes in the shadow of the mechanical aperture of the machine. The longitudinal impedance of this device consists of two distinct components, one from the cavity and the other from the electrodes. The cavity part of the impedance can be reduced by inter-electrode shields as proposed by G. Lambertson. A complementary way of reducing this part of the impedance is to use tapered edges. The cavity wake potential of the beam position monitor is computed both with the 3D code MAFIA and analytically for a very short bunch (20 mm) and for a normal high energy LHC bunch (75 mm). The computation is done separately for the inter-electrode shields and for the tapered ends. The agreement between the two methods is very good, hence it can be concluded that the cavity impedance of the monitor cavity is well known up to the cut-off frequency of the LHC pipe (5.1 GHz). ...

  9. Beam divergence scaling in neutral beam injectors

    International Nuclear Information System (INIS)

    Holmes, A.J.T.

    1976-01-01

    One of the main considerations in the design of neutral beam injectors is to monimize the divergence of the primary ion beam and hence maximize the beam transport and minimize the input of thermal gas. Experimental measurements of the divergence of a cylindrical ion beam are presented and these measurements are used to analyze the major components of ion beam divergence, namely: space charge expansion, gas-ion scattering, emittance and optical aberrations. The implication of these divergence components in the design of a neutral beam injector system is discussed and a method of maximizing the beam current is described for a given area of source plasma

  10. Beam screens for the LHC beam pipes

    CERN Multimedia

    Patrice Loïez

    1997-01-01

    Cross-section of LHC prototype beam pipes showing the beam screens. Slits in the screens allow residual gas molecules to be pumped out and become frozen to the walls of the ultra-cold beam pipe. Beam screens like these have been designed to line the beam pipes, absorbing radiation before it can hit the magnets and warm them up, an effect that would greatly reduce the magnetic field and cause serious damage.

  11. Beam geometry selection using sequential beam addition.

    Science.gov (United States)

    Popple, Richard A; Brezovich, Ivan A; Fiveash, John B

    2014-05-01

    The selection of optimal beam geometry has been of interest since the inception of conformal radiotherapy. The authors report on sequential beam addition, a simple beam geometry selection method, for intensity modulated radiation therapy. The sequential beam addition algorithm (SBA) requires definition of an objective function (score) and a set of candidate beam geometries (pool). In the first iteration, the optimal score is determined for each beam in the pool and the beam with the best score selected. In the next iteration, the optimal score is calculated for each beam remaining in the pool combined with the beam selected in the first iteration, and the best scoring beam is selected. The process is repeated until the desired number of beams is reached. The authors selected three treatment sites, breast, lung, and brain, and determined beam arrangements for up to 11 beams from a pool comprised of 25 equiangular transverse beams. For the brain, arrangements were additionally selected from a pool of 22 noncoplanar beams. Scores were determined for geometries comprised equiangular transverse beams (EQA), as well as two tangential beams for the breast case. In all cases, SBA resulted in scores superior to EQA. The breast case had the strongest dependence on beam geometry, for which only the 7-beam EQA geometry had a score better than the two tangential beams, whereas all SBA geometries with more than two beams were superior. In the lung case, EQA and SBA scores monotonically improved with increasing number of beams; however, SBA required fewer beams to achieve scores equivalent to EQA. For the brain case, SBA with a coplanar pool was equivalent to EQA, while the noncoplanar pool resulted in slightly better scores; however, the dose-volume histograms demonstrated that the differences were not clinically significant. For situations in which beam geometry has a significant effect on the objective function, SBA can identify arrangements equivalent to equiangular

  12. Beam geometry selection using sequential beam addition

    Energy Technology Data Exchange (ETDEWEB)

    Popple, Richard A., E-mail: rpopple@uabmc.edu; Brezovich, Ivan A.; Fiveash, John B. [Department of Radiation Oncology, The University of Alabama at Birmingham, 1720 2nd Avenue South, Birmingham, Alabama 35294 (United States)

    2014-05-15

    Purpose: The selection of optimal beam geometry has been of interest since the inception of conformal radiotherapy. The authors report on sequential beam addition, a simple beam geometry selection method, for intensity modulated radiation therapy. Methods: The sequential beam addition algorithm (SBA) requires definition of an objective function (score) and a set of candidate beam geometries (pool). In the first iteration, the optimal score is determined for each beam in the pool and the beam with the best score selected. In the next iteration, the optimal score is calculated for each beam remaining in the pool combined with the beam selected in the first iteration, and the best scoring beam is selected. The process is repeated until the desired number of beams is reached. The authors selected three treatment sites, breast, lung, and brain, and determined beam arrangements for up to 11 beams from a pool comprised of 25 equiangular transverse beams. For the brain, arrangements were additionally selected from a pool of 22 noncoplanar beams. Scores were determined for geometries comprised equiangular transverse beams (EQA), as well as two tangential beams for the breast case. Results: In all cases, SBA resulted in scores superior to EQA. The breast case had the strongest dependence on beam geometry, for which only the 7-beam EQA geometry had a score better than the two tangential beams, whereas all SBA geometries with more than two beams were superior. In the lung case, EQA and SBA scores monotonically improved with increasing number of beams; however, SBA required fewer beams to achieve scores equivalent to EQA. For the brain case, SBA with a coplanar pool was equivalent to EQA, while the noncoplanar pool resulted in slightly better scores; however, the dose-volume histograms demonstrated that the differences were not clinically significant. Conclusions: For situations in which beam geometry has a significant effect on the objective function, SBA can identify

  13. Early Experience with a Tapered Titanium Porous Plasma Sprayed Stem with Updated Design.

    Science.gov (United States)

    Manocchio, Antonio G; Berend, Keith R; Morris, Michael J; Adams, Joanne B; Lombardi, Adolph V

    2017-12-22

    The Taperloc® Complete femoral stem (Zimmer Biomet, Warsaw, Indiana) builds on the widespread clinical success of the original Taperloc design used since 1982. Enhancements to the Complete design include a lowered caput-collum-diaphyseal (CCD) angle from 138° to 133° for improved offset, optimized neck taper with polished neck flats to increase range of motion, reduced distal geometry to improve proximal canal fill, and gradual off-loading that is the goal of tapered geometry. A retrospective review was conducted to assess our early experience with the updated design. A query of our practice's arthroplasty registry revealed 97 consented patients (103 hips) who underwent primary cementless THA performed with a Taperloc® Complete femoral component between November 2010 and March 2011. A high offset option, accomplished by a constant 7.8mm medial shift of the trunnion, was utilized in 94 hips (91%). Mean age was 61.8 years and body mass index (BMI) was 31.3 kg/m2. Underlying diagnoses were osteoarthritis in 96 (93%), four avascular necrosis, two post-traumatic arthritis, and one acute fracture. Mean follow-up was 5.3 years (2-7). Harris hip scores improved from 53.6 preoperatively to 87.9 at most recent. One stem was revised for periprosthetic fracture. Other reoperations were one cup revised for iliopsoas impingement, one lateral femoral cutaneous neurectomy, and one incision and debridement for a non-healing wound. Postoperative radiographs revealed satisfactory position and alignment of components with no radiolucencies observed in all patients with no evidence of osteolysis, distal hypertrophy, or pedestal formation. In this group, good results with a low frequency of complications and stem revision were achieved with a tapered titanium porous plasma-sprayed femoral component with updated design features. No aseptic loosening or osteolysis occurred. Radiographic findings were excellent in all hips.

  14. Revision Total Hip Arthroplasty With a Monoblock Splined Tapered Grit-Blasted Titanium Stem.

    Science.gov (United States)

    Hellman, Michael D; Kearns, Sean M; Bohl, Daniel D; Haughom, Bryan D; Levine, Brett R

    2017-12-01

    In revision total hip arthroplasty (THA), proximal femoral bone loss creates a challenge of achieving adequate stem fixation. The purpose of this study was to examine the outcomes of a monoblock, splined, tapered femoral stem in revision THA. Outcomes of revision THA using a nonmodular, splined, tapered femoral stem from a single surgeon were reviewed. With a minimum of 2-year follow-up, there were 68 cases (67 patients). Paprosky classification was 3A or greater in 85% of the cases. Preoperative and postoperative Harris Hip Scores (HHS), radiographic subsidence and osseointegration, limb length discrepancy, complications, and reoperations were analyzed. The Harris Hip Score improved from 37.4 ± SD 19.4 preoperatively to 64.6 ± SD 21.8 at final follow-up (P revision procedures-8 for septic indications and 8 for aseptic indications. Subsidence occurred at a rate of 3.0% and dislocation at 7.4%. Limb length discrepancy of more than 1 cm after revision was noted in 13.6% of patients. Bone ingrowth was observed in all but 4 patients (94.1%). At 4-year follow-up, Kaplan-Meier estimated survival was 72.9% (95% confidence interval [CI] 57.0-83.8) for all causes of revision, 86.6% (95% CI 72.0-93.9) for all aseptic revision, and 95.5% (95% CI 86.8-98.5) for aseptic femoral revision. Although complications were significant, revision for femoral aseptic loosening occurred in only 3 patients. Given the ability of this monoblock splined tapered stem to adequately provide fixation during complex revision THA, it remains a viable option in the setting of substantial femoral bone defects. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Wear of Morse taper and external hexagon implant joints after abutment removal.

    Science.gov (United States)

    Prado, Abraão M; Pereira, Jorge; Silva, Filipe S; Henriques, Bruno; Nascimento, Rubens M; Benfatti, Cesar A M; López-López, José; Souza, Júlio C M

    2017-05-01

    The aim of this in vitro study was to evaluate the removal torque values on abutments and the morphological wear aspects of two different dental implant joints after immersion in a medium containing biofilm from human saliva. Twenty implant-abutment assemblies were divided into four groups in this study: (A) Morse taper free of medium containing biofilm, and (B) after contact with a medium containing biofilm from human saliva; (C) External Hexagon free of medium containing biofilm, and (D) after contact with medium containing biofilm from human saliva. The abutments were firstly torqued to the implants according to the manufacturer´s recommendations, using a handheld torque meter. Groups B and D were immersed into 24 well-plates containing 2 ml BHI medium with microorganisms for 72 h at 37 °C under microaerophilic conditions. After detorque evaluation, the abutments were removed and the implants were analyzed by scanning electron microscopy (SEM) and profilometry. On the detorque evaluation, the torque values decreased for the external hexagon implants and increased for the Morse taper implants. However, the values were lower when both implant-abutment assemblies were in contact with a medium containing biofilm from human saliva. The wear areas of contacting surfaces of the implants were identified by SEM. The highest average roughness values were recorded on the surfaces free of biofilm. The medium containing biofilm from human saliva affected the maintenance of the torque values on Morse taper and external hexagon abutments. Additionally, the removal of abutment altered the inner implant surfaces resulting in an increase of wear of the titanium-based connection.

  16. Does the combination of erythropoietin and tapered oral corticosteroids improve recovery following iatrogenic nerve injury?

    Science.gov (United States)

    Bernstein, Derek T; Weiner, Bradley K; Tasciotti, Ennio; Mathis, Kenneth B

    2016-08-01

    The reported prognosis for recovery after peripheral nerve injury is remarkably poor. Deficits may persist for years, resulting in significant functional disability. Both corticosteroids and Erythropoietin have been investigated as neuroprotective agents; however, their efficacy in total hip and knee arthroplasty is not known. The purpose of this study was to evaluate the effect of systemically-administered Erythropoietin and tapered oral corticosteroids on the recovery of postoperative nerve palsies in the setting of total hip and knee arthroplasty. Eleven patients sustaining postoperative peripheral nerve injuries after total hip or knee arthroplasty were treated acutely with Erythropoietin and tapered oral steroids. Motor and sensory function was assessed clinically pre- and postoperatively until complete motor recovery or for a minimum of 1 year. Motor loss was complete in seven (64%) patients and partial in four (36%). Seven (64%) patients' symptoms affected the common peroneal nerve distribution and four (36%) had concomitant tibial nerve involvement. Eight (73%) patients experienced full motor recovery at an average of 39 days (range: 3-133 days), and three (27%) had near-complete motor recovery. At final follow up, no patient required assistive devices for ambulation. Administration of Erythropoietin coupled with oral tapered steroids for patients sustaining iatrogenic nerve injuries in total hip and knee arthroplasty demonstrated faster and more complete recovery of motor and sensory function compared to previous reports in the literature. This study highlights the importance of further investigation to define the role of each in the setting of acute postoperative nerve palsies. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Opioid tapering in patients with prescription opioid use disorder: A retrospective study.

    Science.gov (United States)

    Zhou, Kehua; Jia, Peng; Bhargava, Swati; Zhang, Yong; Reza, Taslima; Peng, Yuan Bo; Wang, Gary G

    2017-10-01

    Opioid use disorder (OUD) refers to a maladaptive pattern of opioid use leading to clinically significant impairment or distress. OUD causes, and vice versa, misuses and abuse of opioid medications. Clinicians face daily challenges to treat patients with prescription opioid use disorder. An evidence-based management for people who are already addicted to opioids has been identified as the national priority in the US; however, options are limited in clinical practices. In this study, we aimed to explore the success rate and important adjuvant medications in the medication assisted treatment with temporary use of methadone for opioid discontinuation in patients with prescription OUD. This is a retrospective chart review performed at a private physician office for physical medicine and rehabilitation. We reviewed all medical records dated between December 1st, 2011 and August 30th, 2016. The initial evaluation of the included patients (N=140) was completed between December 1st, 2011 and December 31st, 2014. They all have concumittant prescription OUD and chronic non-cancer pain. The patients (87 female and 53 male) were 46.7±12.7 years old, and had a history of opioid use of 7.7±6.1 years. All patients received the comprehensive opioid taper treatments (including interventional pain management techniques, psychotherapy, acupuncture, physical modalities and exercises, and adjuvant medications) on top of the medication assisted treatment using methadone (transient use). Opioid tapering was considered successful when no opioid medication was used in the last patient visit. The 140 patients had pain of 9.6±8.4 years with 8/10 intensity before treatment which decreased after treatment in all comparisons (pOUD. For patients with OUD, indefinite opioid maintenance treatment may not be necessary. Considering the ethical values of autonomy, nonmaleficence, and beneficence, clinicians should provide patients with OUD the option of opioid tapering. Copyright © 2017

  18. Laboratory evaluations of a bi-level, extremely tapered bristled toothbrush and a conventional uniform bristled toothbrush.

    Science.gov (United States)

    Barnes, Caren M; Covey, David A; Shi, Xiuren; Yankell, Samuel L

    2009-04-01

    To compare a uniquely shaped tapered-bristle manual toothbrush to a toothbrush with bristles uniform in height and diameter for the ability to remove artificial plaque deposits in areas of the mouth that are difficult to access; interproximal areas, the gingival margin and subgingival. This study compared a GUM Summit+ Compact toothbrush featuring extremely tapered bristles and conventional bristle ends in a bi-level design. The upper, longest tapered bristles have the final 6 mm tapered to 0.01 diameter mm at the end. The conventional rounded end bristles have less than 0.5 mm tapered down to 0.02 mm diameter. The comparison manual toothbrush (Oral-B 40 Indicator) has bristles that are uniform in height and diameter. Interproximal access efficacy was evaluated using a pressure-sensitive artificial plaque substrate placed around simulated anterior and posterior teeth. Subgingival access and gingival margin cleaning were determined by using simulated gingiva prepared with a 0.2 mm space between the gingiva and the artificial plaque substrate on tooth surfaces and results were recorded as the artificial plaque removed below the gingiva or around the gingival margin. Interproximal access values were significantly (P toothbrush was statistically significantly more effective for removing plaque from the interproximal areas, at the gingival margin and subgingivally than the Oral-B 40 Indicator toothbrush.

  19. Effects of taper on swimming force and swimmer performance after an experimental ten-week training program.

    Science.gov (United States)

    Papoti, Marcelo; Martins, Luis E B; Cunha, Sergio A; Zagatto, Alessandro M; Gobatto, Claudio A

    2007-05-01

    The purpose of this research was to examine how an 11-day taper after an 8.5-week experimental training cycle affected lactate levels during maximal exercise, mean force, and performance in training swimmers, independent of shaving, psychological changes, and postcompetition effects. Fourteen competition swimmers with shaved legs and torsos were recruited from the São Paulo Aquatic Federation. The training cycle consisted of a basic training period (endurance and quality phases) of 8.5 weeks, with 5,800 m.d(-1) mean training volume and 6 d.wk(-1) frequency; and a taper period (TP) of 1.5 weeks' duration that incorporated a 48% reduction in weekly volume without altering intensity. Attained swimming force (SF) and maximal performance over 200-m maximal swim (Pmax) before and after taper were measured. After taper, SF and Pmax improved 3.6 and 1.6%, respectively (p swimming velocity, but not in the same proportion as force after taper, suggesting that there are other factors influencing performance in faster swimming.

  20. Adaptable Optical Fiber Displacement-Curvature Sensor Based on a Modal Michelson Interferometer with a Tapered Single Mode Fiber.

    Science.gov (United States)

    Salceda-Delgado, G; Martinez-Rios, A; Selvas-Aguilar, R; Álvarez-Tamayo, R I; Castillo-Guzman, A; Ibarra-Escamilla, B; Durán-Ramírez, V M; Enriquez-Gomez, L F

    2017-06-02

    A compact, highly sensitive optical fiber displacement and curvature radius sensor is presented. The device consists of an adiabatic bi-conical fused fiber taper spliced to a single-mode fiber (SMF) segment with a flat face end. The bi-conical taper structure acts as a modal coupling device between core and cladding modes for the SMF segment. When the bi-conical taper is bent by an axial displacement, the symmetrical bi-conical shape of the tapered structure is stressed, causing a change in the refractive index profile which becomes asymmetric. As a result, the taper adiabaticity is lost, and interference between modes appears. As the bending increases, a small change in the fringe visibility and a wavelength shift on the periodical reflection spectrum of the in-fiber interferometer is produced. The displacement sensitivity and the spectral periodicity of the device can be adjusted by the proper selection of the SMF length. Sensitivities from around 1.93 to 3.4 nm/mm were obtained for SMF length between 7.5 and 12.5 cm. Both sensor interrogations, wavelength shift and visibility contrast, can be used to measure displacement and curvature radius magnitudes.

  1. Stress distribution of new generation of Twisted Files in comparison with ProTaper: A finite element analysis

    Directory of Open Access Journals (Sweden)

    Harsha Pujari

    2013-01-01

    Full Text Available Aim: To compare and evaluate the stress distribution of new generation of Twisted File in comparison with ProTaper under bending or torsional conditions using a finite - element analysis model. Materials and Methods: Two NiTi files, a ProTaper file and the latest generation nickel titanium file which is the Twisted File of similar tip diameter were scanned using White light scanning system. Through this a real size digitized models of the two brands of NiTi instruments were obtained. Then, the outline of the instrument was extracted from the stacks of 3D data in software. Finally a mesh of linear, eight-noded, hexahedral elements was overlaid onto the rendered 3D image. The behavior of the instrument under bending or torsional loads was then analyzed mathematically in the software (ABAQUS V6, 5-1 taking into consideration the non linear mechanical characteristic of NiTi material. The results were expressed as von Mises stresses and were calculated by the von Mises criteria. Results: Higher stress values were seen in Twisted Files than the ProTaper universal, however, the angular deflection was seen to be more in Twisted Files. Conclusion: As more angular deflection was seen in Twisted File it was more flexible than ProTaper Universal but did not have the uniform stress distribution like the ProTaper universal.

  2. A Review of Multimode Interference in Tapered Optical Fibers and Related Applications

    Science.gov (United States)

    Wang, Pengfei; Zhao, Haiyan; Wang, Xianfan; Brambilla, Gilberto

    2018-01-01

    In recent years, tapered optical fibers (TOFs) have attracted increasing interest and developed into a range of devices used in many practical applications ranging from optical communication, sensing to optical manipulation and high-Q resonators. Compared with conventional optical fibers, TOFs possess a range of unique features, such as large evanescent field, strong optical confinement, mechanical flexibility and compactness. In this review, we critically summarize the multimode interference in TOFs and some of its applications with a focus on our research project undertaken at the Optoelectronics Research Centre of the University of Southampton in the United Kingdom. PMID:29538333

  3. Wear of K3 and ProTaper files after simulated clinical use in curved canals

    Directory of Open Access Journals (Sweden)

    Patrícia de Almeida Rodrigues Silva e Souza

    2009-01-01

    Full Text Available Objective: To assess wear, after simulated clinical use of K3 (SybronEndo, Orange, CA, EUA and ProTaper files (Dentsply-Maillefer, Tulsa, Oklahoma, EUA in 46 mesiovestibular roots of human maxillary first molars, recently extracted and with mean angulation of 40°.Methods: The teeth were divided as follows: a K3 (SybronEndo, Orange, CA, EUA (with radial bands and b ProTaper (Dentsply-Maillefer, Tulsa, Oklahoma, EUA (without radial bands. The files were assessed by scanning electronic microscopy before first use to visualize fabrication defects, and after 7 and 13 cycles of debridement in the canals. Debridement with files K3 (SybronEndo, Orange, CA, EUA and ProTaper (Dentsply-Maillefer, Tulsa, Oklahoma, EUA was performed in accordance with the manufacturers’ recommendations. The criteria for wear assessment were: defects (stretching, shortening/spiral inversion, presence of craters, oblique cracks and fracture. After assessment by SEM and before they were used, metal barbs on the crest of the spirals and oblique scratches due to the machining process were found in all the files.Results: In the K3 system (SybronEndo, Orange, CA, USA, after being used seven times, all the instruments showed cutting angle defects,and 25/08 and 25/10 had oblique cracks in the body of the active part leading to ductile fracture after being used for the eighth time. In the ProTaper system (Dentsply-Maillefer, Tulsa, Oklahoma, USA, after being used seven times, in addition to cutting angle defects, the files also presented cracks, and ruptile fracture occurred in F3 during use for the thirteenth time. At the end of preparation, craters were seen along the active part of the files.Conclusion: In the final analysis, it was seen that the system are equivalent with regard to the defects found, irrespective of the active part design,being proportional to the number of cycles of use, and these defects could act as points of greater fragility, favoring fracture.

  4. Unlocking high spatial resolution in neutron imaging through an add-on fibre optics taper.

    Science.gov (United States)

    Morgano, M; Trtik, P; Meyer, M; Lehmann, E H; Hovind, J; Strobl, M

    2018-01-22

    The demand for high resolution neutron imaging has been steadily increasing over the past years. The number of facilities offering cutting edge resolution is however limited, due to (i) the design complexity of an optimized device able to reach a resolution in the order of ≈ 10 μm and (ii) limitations in available neutron flux. Here we propose a simple addition, based on a Fibre Optics Taper (FOT), that can be easily attached to an already existing scintillator-camera imaging detector in order to efficiently increase its spatial resolution and hence boost the capability of an instrument into high resolution applications.

  5. Forced Response of Polar Orthotropic Tapered Circular Plates Resting on Elastic Foundation

    Directory of Open Access Journals (Sweden)

    A. H. Ansari

    2016-01-01

    Full Text Available Forced axisymmetric response of polar orthotropic circular plates of linearly varying thickness resting on Winkler type of elastic foundation has been studied on the basis of classical plate theory. An approximate solution of problem has been obtained by Rayleigh Ritz method, which employs functions based upon the static deflection of polar orthotropic circular plates. The effect of transverse loadings has been studied for orthotropic circular plate resting on elastic foundation. The transverse deflections and bending moments are presented for various values of taper parameter, rigidity ratio, foundation parameter, and flexibility parameter under different types of loadings. A comparison of results with those available in literature shows an excellent agreement.

  6. Stability of the mode-locking regime in tapered quantum-dot lasers

    Science.gov (United States)

    Bardella, P.; Drzewietzki, L.; Rossetti, M.; Weber, C.; Breuer, S.

    2018-02-01

    We study numerically and experimentally the role of the injection current and reverse bias voltage on the pulse stability of tapered, passively mode-locked, Quantum Dot (QD) lasers. By using a multi-section delayed differential equation and introducing in the model the QD inhomogenous broadening, we are able to predict the onset of leading and trailing edge instabilities in the emitted pulse trains and to identify specific trends of stability in dependence on the laser biasing conditions. The numerical results are confirmed experimentally trough amplitude and timing stability analysis of the pulses.

  7. Modulation of Frequency Doubled DFB-Tapered Diode Lasers for Medical Treatment

    DEFF Research Database (Denmark)

    Christensen, Mathias; Hansen, Anders Kragh; Noordegraaf, Danny

    2017-01-01

    The use of visible lasers for medical treatments is on the rise, and together with this comes higher expectations for the laser systems. For many medical treatments, such as ophthalmology, doctors require pulse on demand operation together with a complete extinction of the light between pulses. We...... have demonstrated power modulation from 0.1 Hz to 10 kHz at 532 nm with a modulation depth above 97% by wavelength detuning of the laser diode. The laser diode is a 1064 nm monolithic device with a distributed feedback (DFB) laser as the master oscillator (MO), and a tapered power amplifier (PA...

  8. Interaction of whispering-gallery electromagnetic waves with acoustic waves in tapered quartz rods

    International Nuclear Information System (INIS)

    Sychugov, V A; Magdich, L N; Torchigin, V P

    2001-01-01

    The propagation of whispering-gallery waves in a dynamic cavity formed by a tapered quartz rod and the plane interface between two regions of the rod with different refractive indices moving along the axis of the rod is analysed. It is shown that the limiting frequency shift of light in such a cavity is determined by its Q factor and the attainable refractive index discontinuity. The possibility of using acoustic waves for obtaining a dynamic cavity is considered. (laser applications and other topics in quantum electronics)

  9. Effect of Osteotomy Preparation on Osseointegration of Immediately Loaded, Tapered Dental Implants.

    Science.gov (United States)

    Stavropoulos, A; Cochran, D; Obrecht, M; Pippenger, B E; Dard, M

    2016-03-01

    The aim of the present preclinical in vivo study was to evaluate whether a modified "drill-only" protocol, involving slight underpreparation of the implant site, may have an effect on aspects of osseointegration of a novel bone-level tapered implant, compared with the "standard drilling" protocol involving taping and profiling of the marginal aspect of the implant socket. In each side of the edentulated and completely healed mandible of 11 minipigs, 2 tapered implants (8 mm long × 4.1 mm Ø, BLT; Institut Straumann AG, Basel, Switzerland) were installed either with the drill-only or the standard drilling protocol. Significantly lower average insertion torque values were recorded for the standard drilling protocol group (52 ± 29 Ncm) compared with the drill-only group (70 ± 27 Ncm) (t test, P ≤ 0.05); no significant difference was observed between the 2 groups regarding implant stability, by means of resonance frequency analysis (75 ± 8 vs. 75 ± 6, respectively). Half of the implants were immediately loaded and the rest were submerged, providing observation times of 8 or 4 wk, respectively. Non-decalcified histological and histomorphometric analysis of the implants with surrounding tissues showed no significant differences between the 2 drilling protocols regarding the distance from the implant platform to the first coronal bone-to-implant contact (f-BIC), the total bone-to-implant contact (BIC) as a percentage of the total implant perimeter, and the bone density in an area extending 1 mm laterally from the implant (BATA) within 2 rectangular regions of interest (ROIs) 4 mm in height, representing the coronal (parallel-walled) and apical (tapered) aspect of the implant (ROI 1 and ROI 2, respectively) in non-submerged implants. In general, marginal peri-implant bone levels were at or slightly apical to the implant platform, and large amounts of bone-to-implant contact were observed. In contrast, immediately loaded implants placed with the drill-only protocol

  10. Stable beams

    CERN Multimedia

    2015-01-01

    Stable beams: two simple words that carry so much meaning at CERN. When LHC page one switched from "squeeze" to "stable beams" at 10.40 a.m. on Wednesday, 3 June, it triggered scenes of jubilation in control rooms around the CERN sites, as the LHC experiments started to record physics data for the first time in 27 months. This is what CERN is here for, and it’s great to be back in business after such a long period of preparation for the next stage in the LHC adventure.   I’ve said it before, but I’ll say it again. This was a great achievement, and testimony to the hard and dedicated work of so many people in the global CERN community. I could start to list the teams that have contributed, but that would be a mistake. Instead, I’d simply like to say that an achievement as impressive as running the LHC – a machine of superlatives in every respect – takes the combined effort and enthusiasm of everyone ...

  11. Electron dynamics and energy conversion in O-type linear-beam devices.

    Science.gov (United States)

    Detweiler, H. K.; Rowe, J. E.

    1971-01-01

    A general nonlinear interaction theory is used to investigate the effects of transverse fields (i.e., radial circuit fields and radial space-charge fields) in traveling-wave amplifiers for a variety of beam-focusing conditions. Magnetic focusing fields which are periodic or tapered (increased) with distance along the device are considered in addition to uniform magnetic fields. Results are presented for Brillouin flow and near-Brillouin flow, and the minimum magnetic field strength required to effectively constrain the electron beam is determined as a function of the operating parameters for the various focusing systems. Confined flow is also examined for the uniform-field case in order to have a basis of comparison from which the effects of radial motion of the beam electrons can be determined. The results indicate the importance of transverse effects and further yield information on the stability of strongly modulated cylindrical electron beams.-

  12. Design of a wiggler-focused, sheet beam X band klystron

    International Nuclear Information System (INIS)

    Eppley, K.R.; Herrmannsfeldt, W.B.; Miller, R.H.

    1987-02-01

    An X band klystron using a sheet beam and wiggler focusing was simulated using the 2 + 1/2 dimensional particle in cell code MASK. Simulation of the rf cavities was by means of the port approximation used in modelling of standard klystrons. The wigglers, which would need permanent magnets to achieve the required field strengths, were modelled using an idealized analytic expression with an exponential rise and a linear taper superimposed on a sinusoidal variation. Cavity locations and tunings were varied for maximum output power. Beam voltage and current were also varied to explore the effect on efficiency. Both an idealized laminar beam and a more realistic beam from a gun design code were studied. For a voltage of 200 kV and current of 20 amp per linear cm efficiencies of approximately 50% were calculated

  13. Beam-beam effects in the Tevatron

    Energy Technology Data Exchange (ETDEWEB)

    Shiltsev, V.; Alexahin, Y.; Lebedev, V.; Lebrun, P.; Moore, R.S.; Sen, T.; Tollestrup, A.; Valishev, A.; Zhang, X.L.; /Fermilab

    2005-01-01

    The Tevatron in Collider Run II (2001-present) is operating with 6 times more bunches, many times higher beam intensities and luminosities than in Run I (1992-1995). Electromagnetic long-range and head-on interactions of high intensity proton and antiproton beams have been significant sources of beam loss and lifetime limitations. We present observations of the beam-beam phenomena in the Tevatron and results of relevant beam studies. We analyze the data and various methods employed in operations, predict the performance for planned luminosity upgrades, and discuss ways to improve it.

  14. Crystalline beams

    International Nuclear Information System (INIS)

    Schiffer, J.P.

    1989-01-01

    Ions in a storage ring are confined to a mean orbit by focusing elements. To a first approximation these may be described by a constant harmonic restoring force: F = -Kr. If the particles in the frame moving along with the beam have small random thermal energies, then they will occupy a cylindrical volume around the mean orbit and the focusing force will be balanced by that from the mutual repulsion of the particles. Inside the cylinder only residual two-particle interactions will play a significant role and some form of ordering might be expected to take place. The results of some of the first MD calculations showed a surprising result: not only were the particles arranged in the form of a tube, but they formed well-defined layers: concentric shells, with the particles in each shell arranged in a hexagonal lattice that is characteristic of two-dimensional Coulomb systems. This paper discusses the condense layer structure

  15. The seating mechanics of head-neck modular tapers in vitro: Load-displacement measurements, moisture, and rate effects.

    Science.gov (United States)

    Ouellette, Eric S; Shenoy, Aarti A; Gilbert, Jeremy L

    2017-09-08

    The mechanically assisted crevice corrosion performance of head-neck modular tapers is a significant concern in orthopedic biomaterials. Fretting crevice corrosion processes in modular tapers are thought to be influenced by a wide array of factors including seating mechanics of the junction, hence there is a need for in vitro test methods that can assess their performance. This study presented a test method to directly measure the load-displacement seating mechanics of modular tapers and used this method to compare the seating mechanics for different tapers, moisture, seating loads and seating rates. Seating mechanics were explored whereby the instantaneous load-displacement behavior of the head seating onto the neck is captured and used to define the mechanics of seating. Two distinct taper design/material combinations were assembled wet or dry using axially applied loads (500, 1,000, 2,000, and 4,000 N) at two loading rates of 100 and 10 4  N/s (n = 5 for each condition) using a servohydraulic test frame. The results showed that pull-off strength scaled with seating load and ranged between 43% and 68% of seating load depending on sample and wetness. Tapers seated wet had higher pull-off strengths (2,200 ± 300 N) than those seated dry (1,800 ± 200 N, p mechanics (load-displacement plots) varied due to sample type and due to wetness with differences in seating energy, seating stiffness, and seating displacement. These results show the detailed mechanics of seating during assembly and provide significant insight into the complex interplay of factors associated with even "ideal" seating (axial, quasistatic) loading. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 9999:1-9, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  16. Numerical Investigation of Oxygenated and Deoxygenated Blood Flow through a Tapered Stenosed Arteries in Magnetic Field.

    Directory of Open Access Journals (Sweden)

    M Y Abdollahzadeh Jamalabadi

    Full Text Available Current paper is focused on transient modeling of blood flow through a tapered stenosed arteries surrounded a by solenoid under the presence of heat transfer. The oxygenated and deoxygenated blood are considered here by the Newtonian and Non-Newtonian fluid (power law and Carreau-Yasuda models. The governing equations of bio magnetic fluid flow for an incompressible, laminar, homogeneous, non-Newtonian are solved by finite volume method with SIMPLE algorithm for structured grid. Both magnetization and electric current source terms are well thought-out in momentum and energy equations. The effects of fluid viscosity model, Hartmann number, and magnetic number on wall shear stress, shearing stress at the stenosis throat and maximum temperature of the system are investigated and are optimized. The current study results are in agreement with some of the existing findings in the literature and are useful in thermal and mechanical design of spatially varying magnets to control the drug delivery and biomagnetic fluid flows through tapered arteries.

  17. Nonlinear peristaltic motion of a Johnson–Segalman fluid in a tapered asymmetric channel

    Directory of Open Access Journals (Sweden)

    M. Kothandapani

    2016-06-01

    Full Text Available The peristaltic flow analysis in a tapered asymmetric channel has been made for a Johnson–Segalman fluid. The tapered asymmetric channel is assumed to be formed due to a peristaltic wave train on the non-uniform walls having different amplitudes and phase. Two-dimensional equations of a Johnson–Segalman fluid have been simplified by treating a long wavelength and low Reynolds number approximations. The reduced equations are then solved for the stream function, axial velocity and axial pressure gradient using a regular perturbation technique. The expressions for the pressure rise, axial velocity and stream function are sketched and the reasons for the variations observed in various physical parameters are interpreted with valid theory. It has been noticed that peristaltic pumping region and free pumping decrease with an increase in non-uniform parameter and the situation is quite complimentary to the case of augmented pumping. It has also been observed that the size of the tapped bolus decreases with an increase in Weissenberg number.

  18. Torsional Vibrations of a Conic Shaft with Opposite Tapers Carrying Arbitrary Concentrated Elements

    Directory of Open Access Journals (Sweden)

    Jia-Jang Wu

    2013-01-01

    Full Text Available The purpose of this paper is to present the exact solution for free torsional vibrations of a linearly tapered circular shaft carrying a number of concentrated elements. First of all, the equation of motion for free torsional vibration of a conic shaft is transformed into a Bessel equation, and, based on which, the exact displacement function in terms of Bessel functions is obtained. Next, the equations for compatibility of deformations and equilibrium of torsional moments at each attaching point (including the shaft ends between the concentrated elements and the conic shaft with positive and negative tapers are derived. From the last equations, a characteristic equation of the form is obtained. Then, the natural frequencies of the torsional shaft are determined from the determinant equation , and, corresponding to each natural frequency, the column vector for the integration constants, , is obtained from the equation . Substitution of the last integration constants into the associated displacement functions gives the corresponding mode shape of the entire conic shaft. To confirm the reliability of the presented theory, all numerical results obtained from the exact method are compared with those obtained from the conventional finite element method (FEM and good agreement is achieved.

  19. Prospective, 1-year observational study of double-threaded tapered body dental implants with immediate loading.

    Science.gov (United States)

    Kim, Tae Hyung; Knezevic, Alena; Jorgensen, Michael; Rich, Sandra; Nowzari, Hessam

    2015-07-01

    Unlike conventional loading protocols, the immediate loading of single implants has not been fully investigated. The purpose of this study was to assess the prosthetic and esthetic periimplant mucosal outcomes of immediately restored dental implants during a 1-year follow-up. Twenty participants meeting the established inclusion criteria received double-threaded, tapered body dental implants (SuperLine; Dentium). Implants were placed and stabilized at a minimum of 35 Ncm of torque and restored immediately after the surgery with interim restorations. These were replaced with definitive restorations 6 months after implant placement. Clinical measurements at each visit included resonance frequency analysis, the evaluation of the participants' oral health (gingival and plaque indices), and the esthetic outcome of the interim or definitive restoration. Implants placed in this clinical study had a 100% success rate. The oral health and esthetic outcomes were favorable for all participants. Double-threaded, tapered body dental implants that were placed and immediately restored with fixed interim prostheses and with definitive prostheses after 6 months remained stable and functional after 1 year. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  20. Survival Rate of Short, Locking Taper Implants with a Plateau Design: A 5-Year Retrospective Study

    Directory of Open Access Journals (Sweden)

    Kemal Özgür Demiralp

    2015-01-01

    Full Text Available Background. Short implants have become popular in the reconstruction of jaws, especially in cases with limited bone height. Shorter implants, those with locking tapers and plateau root shapes, tend to have longer survival times. We retrospectively investigated the cumulative survival rates of Bicon short implants (<8 mm according to patient variables over a 5-year period. Materials and Methods. This study included 111 consecutively treated patients with 371 implants supporting fixed or removable prosthetics. Data were evaluated to acquire cumulative survival rates according to gender, age, tobacco use, surgical procedure, bone quality, and restoration type. Statistics were performed using chi-square, Mann-Whitney, and Kruskal Wallis H tests. Results. The survival rate was 97.3% with, on average, 22.8 months of follow-up. Patients older than 60 years had higher failure rate than the other age groups (P<0.05. Placed region, age, and bone quality had adverse effects on survival rate in the <8 mm implant group with statistically significant difference (P<0.05. Conclusions. Approximately 23-month follow-up data indicate that short implants with locking tapers and plateau-type roots have comparable survival rates as other types of dental implants. However, due to limitations of study, these issues remain to be further investigated in future randomized controlled clinical trials.

  1. Performance study of winglets on tapered wing with curved trailing edge

    Science.gov (United States)

    Ara, Ismat; Ali, Mohammad; Islam, Md. Quamrul; Haque, M. Nazmul

    2017-06-01

    Induced drag is the result of wingtip vortex produced from generating lift by finite wing. It is one of the main drags that an aircraft wing encounters during flight. It hampers aircraft performance by increasing fuel consumption and reducing endurance, range and speed. Winglets are used to reduce the induced drag. They weakens wingtip vortex and thus reduces induced drag. This paper represents the experimental investigation to reduce induced drag using winglet at the wingtip. A model of tapered wing with curved trailing edge (without winglet) as well as two similar wings with blended winglet and double blended winglet are prepared using NACA 4412 aerofoil in equal span and surface area. All the models are tested in a closed circuit subsonic wind tunnel at air speed of 108 km/h (0.09 Mach). Reynolds number of the flow is 2.28 × 105 on the basis of average chord length of the wings. The point surface static pressures at different angles of attack from -4° to 24° are measured for each of the wing and winglet combinations through different pressure tapings by using a multi-tube water manometer. From the static pressure distribution, lift coefficient, drag coefficient and lift to drag ratio of all models are calculated. From the analysis of calculated values, it is found that both winglets are able to minimize induced drag; however, the tapered curved trailing edge span with blended winglet provides better aerodynamic performance.

  2. Survival rate of short, locking taper implants with a plateau design: a 5-year retrospective study.

    Science.gov (United States)

    Demiralp, Kemal Özgür; Akbulut, Nihat; Kursun, Sebnem; Argun, Didem; Bagis, Nilsun; Orhan, Kaan

    2015-01-01

    Short implants have become popular in the reconstruction of jaws, especially in cases with limited bone height. Shorter implants, those with locking tapers and plateau root shapes, tend to have longer survival times. We retrospectively investigated the cumulative survival rates of Bicon short implants (implants supporting fixed or removable prosthetics. Data were evaluated to acquire cumulative survival rates according to gender, age, tobacco use, surgical procedure, bone quality, and restoration type. Statistics were performed using chi-square, Mann-Whitney, and Kruskal Wallis H tests. The survival rate was 97.3% with, on average, 22.8 months of follow-up. Patients older than 60 years had higher failure rate than the other age groups (P implant group with statistically significant difference (P short implants with locking tapers and plateau-type roots have comparable survival rates as other types of dental implants. However, due to limitations of study, these issues remain to be further investigated in future randomized controlled clinical trials.

  3. Real-time monitoring of intracellular signal transduction in PC12 cells by non-adiabatic tapered optical fiber biosensor

    Science.gov (United States)

    Zibaii, M. I.; Latifi, H.; Asadollahi, A.; Noraeipoor, Z.; Dargahi, L.

    2014-05-01

    Real-time observation of intracellular process of signal transduction is very useful for biomedical and pharmaceutical applications as well as for basic research work of cell biology. For feasible and reagentless observation of intracellular alterations in real time, we examined the use of a nonadiabatic tapered optical fiber (NATOF) biosensor for monitoring of intracellular signal transduction that was mainly translocation of protein kinase C via refractive index change in PC12 cells adhered on tapered fiber sensor without any indicator reagent. PC12 cells were stimulated with KCl . Our results suggest that complex intracellular reactions could be real-time monitored and characterized by NATOF biosensor.

  4. Comparison of root canal preparation using RaCe and ProTaper rotary Ni-Ti instruments.

    Science.gov (United States)

    Paqué, F; Musch, U; Hülsmann, M

    2005-01-01

    To compare various parameters of root canal preparation using RaCe (FKG Dentaire, La-Chaux-de-Fonds, Switzerland) and ProTaper (Dentsply Maillefer, Ballaigues, Switzerland) nickel-titanium (Ni-Ti) instruments. Fifty extracted mandibular molars with mesial root canal curvatures between 20 degrees and 40 degrees were embedded in a muffle system. All root canals were prepared to size 30 using RaCe or ProTaper rotary instruments in low-torque motors with torque control and constant speed of 300 r.p.m. (ProTaper with ATR Tecnika, Advanced Technology Research, Pistoia, Italy; RaCe with EndoStepper, S.E.T., Olching, Germany). In both groups irrigation was performed with 2 mL NaOCl (3%) after each instrument size. Calcinase-Slide (lege artis, Dettenhausen, Germany) was used as a chelating agent with each instrument. The following parameters were evaluated: straightening of curved root canals, postoperative root canal cross-sections, safety issues and working time. Cleanliness of the root canal walls was investigated under the SEM using 5-score indices for debris and smear layer. Statistical analysis was performed using the following tests: Wilcoxon's test for straightening and working time was used (P < 0.05); Fisher's exact test for comparison of cross-sections and root canal cleanliness (P < 0.05). Both Ni-Ti systems maintained curvature well; the mean degree of straightening was less than 1 degrees for both systems. Following preparation with RaCe, 49% of the root canals had a round or oval diameter and 50% an irregular diameter, ProTaper preparations resulted in a round or oval diameter in 50% of the cases. For debris, RaCe and ProTaper achieved 47 and 49% scores of 1 and 2, respectively; there was no significant difference. For smear layer, RaCe and ProTaper achieved 51 and 33% scores 1 and 2, respectively; no statistically significant differences were apparent for the coronal and middle sections of the root canals, but RaCe performed significantly better in the

  5. Management of female congenital short patulous urethra with urethral tapering and pubovaginal sling: A report of two cases.

    Science.gov (United States)

    Gahlawat, Sumit; Goel, Hemant; Khattar, Nikhil

    2018-01-01

    Congenital short patulous urethra is a rare entity and may be associated with developmental anomalies of mullerian ducts or urogenital sinus. We report the management of two cases of congenital short patulous urethra with stress urinary incontinence (SUI). Both the patients presented with SUI; one was diagnosed with Mayer-Rokitansky-Kuster-Hauser (MRKH) syndrome and the other had uterus didelphys with longitudinally septated vagina. Both patients were successfully managed by excisional tapering of the urethra and pubovaginal sling placement. SUI with congenital short patulous urethra can be managed with excisional tapering of urethra and pubovaginal sling placement.

  6. High-precision laser microcutting and laser microdrilling using diffractive beam-splitting and high-precision flexible beam alignment

    Science.gov (United States)

    Zibner, F.; Fornaroli, C.; Holtkamp, J.; Shachaf, Lior; Kaplan, Natan; Gillner, A.

    2017-08-01

    High-precision laser micro machining gains more importance in industrial applications every month. Optical systems like the helical optics offer highest quality together with controllable and adjustable drilling geometry, thus as taper angle, aspect ratio and heat effected zone. The helical optics is based on a rotating Dove-prism which is mounted in a hollow shaft engine together with other optical elements like wedge prisms and plane plates. Although the achieved quality can be interpreted as extremely high the low process efficiency is a main reason that this manufacturing technology has only limited demand within the industrial market. The objective of the research studies presented in this paper is to dramatically increase process efficiency as well as process flexibility. During the last years, the average power of commercial ultra-short pulsed laser sources has increased significantly. The efficient utilization of the high average laser power in the field of material processing requires an effective distribution of the laser power onto the work piece. One approach to increase the efficiency is the application of beam splitting devices to enable parallel processing. Multi beam processing is used to parallelize the fabrication of periodic structures as most application only require a partial amount of the emitted ultra-short pulsed laser power. In order to achieve highest flexibility while using multi beam processing the single beams are diverted and re-guided in a way that enables the opportunity to process with each partial beam on locally apart probes or semimanufactures.

  7. Beam halo in high-intensity beams

    International Nuclear Information System (INIS)

    Wangler, T.P.

    1993-01-01

    In space-charge dominated beams the nonlinear space-charge forces produce a filamentation pattern, which in projection to the 2-D phase spaces results in a 2-component beam consisting of an inner core and a diffuse outer halo. The beam-halo is of concern for a next generation of cw, high-power proton linacs that could be applied to intense neutron generators for nuclear materials processing. The author describes what has been learned about beam halo and the evolution of space-charge dominated beams using numerical simulations of initial laminar beams in uniform linear focusing channels. Initial results are presented from a study of beam entropy for an intense space-charge dominated beam

  8. Strain analysis of different diameter Morse taper implants under overloading compressive conditions

    Directory of Open Access Journals (Sweden)

    Carolina Guimarães CASTRO

    2015-01-01

    Full Text Available The aim of this study was to evaluate the amount of deformation from compression caused by different diameters of Morse taper implants and the residual deformation after load removal. Thirty Morse taper implants lacking external threads were divided into 3 groups (n = 10 according to their diameter as follows: 3.5 mm, 4.0 mm and 5.0 mm. Two-piece abutments were fixed into the implants, and the samples were subjected to compressive axial loading up to 1500 N of force. During the test, one strain gauge remained fixed to the cervical portion of each implant to measure the strain variation. The strain values were recorded at two different time points: at the maximum load (1500 N and 60 seconds after load removal. To calculate the strain at the implant/abutment interface, a mathematical formula was applied. Data were analyzed using a one-way Anova and Tukey’s test (α = 0.05. The 5.0 mm diameter implant showed a significantly lower strain (650.5 μS ± 170.0 than the 4.0 mm group (1170.2 μS ± 374.7 and the 3.5 mm group (1388.1 μS ± 326.6 (p < 0.001, regardless of the load presence. The strain values decreased by approximately 50% after removal of the load, regardless of the implant diameter. The 5.0 mm implant showed a significantly lower strain at the implant/abutment interface (943.4 μS ± 504.5 than the 4.0 mm group (1057.4 μS ± 681.3 and the 3.5 mm group (1159.6 μS ± 425.9 (p < 0.001. According to the results of this study, the diameter influenced the strain around the internal and external walls of the cervical region of Morse taper implants; all diameters demonstrated clinically acceptable values of strain.

  9. Wakefield and the diffraction model due to a flat beam moving past a conducting wedge

    International Nuclear Information System (INIS)

    Chao, A.W.; Henke, H.

    1995-07-01

    A collimator is often used to clean a beam of its excessive tail particles. If the beam intensity is high enough or if the beam is brought too close to the collimator, however, the wakefields generated by the beam-collimator interaction can cause additional beam tails to grow, thus defeating, or even worsening, the beam-tail cleaning process. The wakefield generated by a sheet beam moving past a conducting wedge has been obtained in closed form by Henke using the method of conformal mapping. This result is applied in the present work to obtain the wake force and the transverse kick received by a test charge moving with the beam. For the beam to be approximated as sheet beams, it is assumed to be flat and the collimator is assumed to have an infinite extent in the flat dimention. We derive an exact expression for the transverse wake force delivered to particles in the beam bunch. Implication of emittance growth as a beam passes closely by a collimator is discussed. We consider two idealized wedge geometries: In Section 2, when the wedge has the geometry as a disrupted beam pipe, and in Section 3, when it is like a semi-infinite screen. Unfortunately, we do not have solutions for more realistic collimator geometries such as when it is tapered to minimize the wakefield effects. However, our results should still serve as pessimistic limiting cases. An interesting opportunity is offered by our exact calculation of the wakefields: it can be used to confront the diffraction model used to estimate the high-frequency impedance of a cavity structure. It is shown that the field pattern, as well as the impedance, agrees with those obtained by the diffraction model in appropriate limits

  10. Electron beam control for barely separated beams

    Energy Technology Data Exchange (ETDEWEB)

    Douglas, David R.; Ament, Lucas J. P.

    2017-04-18

    A method for achieving independent control of multiple beams in close proximity to one another, such as in a multi-pass accelerator where coaxial beams are at different energies, but moving on a common axis, and need to be split into spatially separated beams for efficient recirculation transport. The method for independent control includes placing a magnet arrangement in the path of the barely separated beams with the magnet arrangement including at least two multipole magnets spaced closely together and having a multipole distribution including at least one odd multipole and one even multipole. The magnetic fields are then tuned to cancel out for a first of the barely separated beams to allow independent control of the second beam with common magnets. The magnetic fields may be tuned to cancel out either the dipole component or tuned to cancel out the quadrupole component in order to independently control the separate beams.

  11. Literature in Focus Beta Beams: Neutrino Beams

    CERN Multimedia

    2009-01-01

    By Mats Lindroos (CERN) and Mauro Mezzetto (INFN Padova, Italy) Imperial Press, 2009 The beta-beam concept for the generation of electron neutrino beams was first proposed by Piero Zucchelli in 2002. The idea created quite a stir, challenging the idea that intense neutrino beams only could be produced from the decay of pions or muons in classical neutrino beams facilities or in future neutrino factories. The concept initially struggled to make an impact but the hard work by many machine physicists, phenomenologists and theoreticians over the last five years has won the beta-beam a well-earned position as one of the frontrunners for a possible future world laboratory for high intensity neutrino oscillation physics. This is the first complete monograph on the beta-beam concept. The book describes both technical aspects and experimental aspects of the beta-beam, providing students and scientists with an insight into the possibilities o...

  12. Beam Techniques - Beam Control and Manipulation

    Energy Technology Data Exchange (ETDEWEB)

    Minty, Michiko G

    2003-04-24

    We describe commonly used strategies for the control of charged particle beams and the manipulation of their properties. Emphasis is placed on relativistic beams in linear accelerators and storage rings. After a brief review of linear optics, we discuss basic and advanced beam control techniques, such as transverse and longitudinal lattice diagnostics, matching, orbit correction and steering, beam-based alignment, and linac emittance preservation. A variety of methods for the manipulation of particle beam properties are also presented, for instance, bunch length and energy compression, bunch rotation, changes to the damping partition number, and beam collimation. The different procedures are illustrated by examples from various accelerators. Special topics include injection and extraction methods, beam cooling, spin transport and polarization.

  13. Finite element analysis of stress extent at peri-implant bone surrounding external hexagon or Morse taper implants.

    Science.gov (United States)

    Macedo, J P; Pereira, J; Faria, J; Pereira, C A; Alves, J L; Henriques, B; Souza, J C M; López-López, J

    2017-07-01

    The purpose of the present study was to evaluate the distribution of stresses and consequent bone volume affected surrounding external hexagon or Morse taper dental implant systems by finite element analysis. Two different dental implant-abutment designs were assessed: external hexagon or Morse taper joints. A mandibular bone model obtained from a computed tomography scan was used. The implant-abutment systems were axially or obliquely (45°) loaded on 150 N relatively to the central axis of the implant. The von Mises stresses were analysed in terms of magnitude and volume of affected surrounding bone. The von Mises equivalent values found on the cortical bone were higher than that recorded on the trabecular bone. Additionally, the bone volume associated with high stress values was higher in cortical and trabecular bone for oblique loading compared to axial loading. The values of von Mises equivalent stress around Morse taper implant-abutment system were lower on both axial and oblique loads than those recorded for external hexagon implant-abutment systems. Morse taper implant joints revealed a proper biomechanical behavior when compared to external hexagon systems concerning a significant volume of surrounding peri-implant bone subjected to lower stresses values. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. High Sensitivity Refractometer Based on TiO2-Coated Adiabatic Tapered Optical Fiber via ALD Technology

    Science.gov (United States)

    Zhu, Shan; Pang, Fufei; Huang, Sujuan; Zou, Fang; Guo, Qiang; Wen, Jianxiang; Wang, Tingyun

    2016-01-01

    Atomic layer deposition (ALD) technology is introduced to fabricate a high sensitivity refractometer based on an adiabatic tapered optical fiber. Different thicknesses of titanium dioxide (TiO2) nanofilm were coated around the tapered fiber precisely and uniformly under different deposition cycles. Attributed to the higher refractive index of the TiO2 nanofilm compared to that of silica, an asymmetric Fabry–Perot (F-P) resonator could be constructed along the fiber taper. The central wavelength of the F-P resonator could be controlled by adjusting the thickness of the TiO2 nanofilm. Such a F-P resonator is sensitive to changes in the surrounding refractive index (SRI), which is utilized to realize a high sensitivity refractometer. The refractometer developed by depositing 50.9-nm-thickness TiO2 on the tapered fiber shows SRI sensitivity as high as 7096 nm/RIU in the SRI range of 1.3373–1.3500. Due to TiO2’s advantages of high refractive index, lack of toxicity, and good biocompatibility, this refractometer is expected to have wide applications in the biochemical sensing field. PMID:27537885

  15. Tunable high-power narrow-spectrum external-cavity diode laser based on tapered amplifier at 668 nm

    DEFF Research Database (Denmark)

    Chi, Mingjun; Erbert, G.; Sumpf, B.

    2010-01-01

    A 668 nm tunable high-power narrow-spectrum diode laser system based on a tapered semiconductor optical amplifier in external cavity is demonstrated. The laser system is tunable from 659 to 675 nm. As high as 1.38 W output power is obtained at 668.35 nm. The emission spectral bandwidth is less than...

  16. Detoxification with titration and tapering in gamma-hydroxybutyrate (GHB) dependent patients : The Dutch GHB monitor project

    NARCIS (Netherlands)

    Dijkstra, Boukje A G; Kamal, Rama; van Noorden, Martijn S; de Haan, Hein; Loonen, Anton J.M.; De Jong, Cor A J

    2016-01-01

    BACKGROUND AND AIMS: Gamma-hydroxybutyrate (GHB) detoxification procedures have been insufficiently studied for effectiveness and safety. Based on case reports, benzodiazepines are generally regarded as first-choice agents in GHB detoxification. Detoxification by titration and tapering (DeTiTap)

  17. 78 FR 40692 - Tapered Roller Bearings and Parts Thereof, Finished and Unfinished, From the People's Republic of...

    Science.gov (United States)

    2013-07-08

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-601] Tapered Roller Bearings and..., International Trade Administration, Department of Commerce. SUMMARY: The Department of Commerce (Department) is... Department selected one mandatory respondent for individual examination (i.e., Changshan Peer Bearing Co. Ltd...

  18. Beliefs about the causes of depression and recovery and their impact on adherence, dosage, and successful tapering of antidepressants

    NARCIS (Netherlands)

    Klein, Nicola S.; van Rijsbergen, Gerard D.; ten Doesschate, Mascha C.; Hollon, Steven D.; Burger, Huibert; Bockting, Claudi L.H.

    2017-01-01

    Background: Continuation of antidepressant medication (ADM) after remission is widely used to prevent depressive relapse/recurrence. Little is known about predictors of ADM use in terms of adherence, dosage, and successful tapering. The current study aimed to explore beliefs about the causes of

  19. Beliefs about the causes of depression and recovery and their impact on adherence, dosage, and successful tapering of antidepressants

    NARCIS (Netherlands)

    Klein, Nicola; van Rijsbergen, Gerard; ten Doesschate, Mascha C.; Hollon, Steven D.; Burger, Huibert; Bockting, Claudi

    BACKGROUND: Continuation of antidepressant medication (ADM) after remission is widely used to prevent depressive relapse/recurrence. Little is known about predictors of ADM use in terms of adherence, dosage, and successful tapering. The current study aimed to explore beliefs about the causes of

  20. Rapid detoxification from opioid dependence under general anaesthesia versus standard methadone tapering : abstinence rates and withdrawal distress experiences

    NARCIS (Netherlands)

    Krabbe, Paul F M; Koning, Jeroen P F; Heinen, Nadia; Laheij, Robert J F; van Cauter, R M Victory; De Jong, Cor A J

    The aim of this work was to study abstinence rates and withdrawal effects of rapid detoxification of opioid-dependents under general anaesthesia (RD-GA) compared to standard methadone tapering (SMT) using a prospective clinical trial with a follow-up of 3 months, as a preliminary study at the

  1. Rapid detoxification from opioid dependence under general anaesthesia versus standard methadone tapering: abstinence rates and withdrawal distress experiences.

    NARCIS (Netherlands)

    Krabbe, P.F.M.; Koning, J.P.; Heinen, N.; Laheij, R.J.F.; Cauter, R.M.V. van; Jong, C.A.J. de

    2003-01-01

    The aim of this work was to study abstinence rates and withdrawal effects of rapid detoxification of opioid-dependents under general anaesthesia (RD-GA) compared to standard methadone tapering (SMT) using a prospective clinical trial with a follow-up of 3 months, as a preliminary study at the

  2. Centering Ability of ProTaper Next and WaveOne Classic in J-Shape Simulated Root Canals.

    Science.gov (United States)

    Troiano, Giuseppe; Dioguardi, Mario; Cocco, Armando; Giuliani, Michele; Fabiani, Cristiano; D'Alessandro, Alfonso; Ciavarella, Domenico; Lo Muzio, Lorenzo

    Introduction . The aim of this study was to evaluate and compare the shaping and centering ability of ProTaper Next (PTN; Dentsply Maillefer, Ballaigues, Switzerland) and WaveOne Classic systems (Dentsply Maillefer) in simulated root canals. Methods . Forty J-shaped canals in resin blocks were assigned to two groups ( n = 20 for each group). Photographic method was used to record pre- and postinstrumentation images. After superimposition, centering and shaping ability were recorded at 9 different levels from the apex using the software Autocad 2013 (Autodesk Inc., San Rafael, USA). Results . Shaping procedures with ProTaper Next resulted in a lower amount of resin removed at each reference point level. In addition, the pattern of centering ability improved after the use of ProTaper Next in 8 of 9 measurement points. Conclusions . Within the limitations of this study, shaping procedures with ProTaper Next instruments demonstrated a lower amount of resin removed and a better centering ability than WaveOne Classic system.

  3. 78 FR 45912 - Tapered Roller Bearings and Parts Thereof, Finished and Unfinished, From the People's Republic of...

    Science.gov (United States)

    2013-07-30

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-601] Tapered Roller Bearings and..., International Trade Administration, U.S. Department of Commerce, 14th Street and Constitution Avenue NW... Duty New Shipper Review AGENCY: Import Administration, International Trade Administration, Department...

  4. Nonadiabatic tapered optical fiber sensor for measuring interaction nicotine with DNA

    Science.gov (United States)

    Zibaii, M. I.; Latifi, H.; Pourbeyram, H.; Gholami, M.; Taghipour, Z.; Saeedian, Z.; Hosseini, S. M.

    2011-05-01

    A nonadiabatic tapered optical fiber sensor was utilized for studying of bimolecular interactions including DNA-DNA and DNA-Drug interaction. This work presents a simple evanescent wave sensing system based on an interferometric approach, suitable to meet the requirements of lable-free sensor systems for detecting biomolecular interactions. We have demonstrated the measuring refractive index and the real time detection of interactions between biomolecules. Furthermore basic experiments were carried out, for detecting the hybridization of 25-mer DNA with an immobilized counterpart on the surface. The overall shift after the successful DNA hybridization was 9.5 nm. In this work, a new approach for studying DNA-drug interactions was successfully tested. Nicotine as a carcinogenic compound in cigarette smoke plays an important role in interaction with DNA. Different concentrations of nicotine were applied to observe the Longmuir interaction with DNA.

  5. An Analytical Approach on Thermally Induced Vibrations of Nonhomogeneous Tapered Plate

    Directory of Open Access Journals (Sweden)

    Anupam Khanna

    2013-01-01

    Full Text Available A mathematical model to control the vibrations of a rectangular plate is constructed with an aim to assist engineers in designing and fabrication of various structures used in the field of science and technology, mostly used in satellite and aeronautical engineering. The present study is related to the analysis of free vibrations of nonhomogeneous rectangular plate clamped at all the four edges. Authors studied the bilinear effect of thickness as well as temperature variations in both and directions. Variation in Poisson's ratio is also considered linearly in -direction due to nonhomogeneity. Rayleigh-Ritz method is used to analyze the frequencies for the first two modes of vibrations for different values of thermal gradient, nonhomogeneity constant, taper constants and aspect ratio. All the numerical computations have been performed for an alloy of aluminum, that is, duralumin. All the results are presented in the form of graphs.

  6. Mathematical Modelling of Blood Flow through a Tapered Overlapping Stenosed Artery with Variable Viscosity

    Directory of Open Access Journals (Sweden)

    G. C. Shit

    2014-01-01

    Full Text Available This paper presents a theoretical study of blood flow through a tapered and overlapping stenosed artery under the action of an externally applied magnetic field. The fluid (blood medium is assumed to be porous in nature. The variable viscosity of blood depending on hematocrit (percentage volume of erythrocytes is taken into account in order to improve resemblance to the real situation. The governing equation for laminar, incompressible and Newtonian fluid subject to the boundary conditions is solved by using a well known Frobenius method. The analytical expressions for velocity component, volumetric flow rate, wall shear stress and pressure gradient are obtained. The numerical values are extracted from these analytical expressions and are presented graphically. It is observed that the influence of hematocrit, magnetic field and the shape of artery have important impact on the velocity profile, pressure gradient and wall shear stress. Moreover, the effect of primary stenosis on the secondary one has been significantly observed.

  7. Design Analysis of Taper Width Variations in Magnetless Linear Machine for Traction Applications

    Directory of Open Access Journals (Sweden)

    Saadha Aminath

    2018-01-01

    Full Text Available Linear motors are being used in a different application with a huge popularity in the use of transport industry. With the invention of maglev trains and other high-speed trains, linear motors are being used for the translation and braking applications for these systems. However, a huge drawback of the linear motor design is the cogging force, low thrust values, and voltage ripples. This paper aims to study the force analysis with change in taper/teeth width of the motor stator and mover to understand the best teeth ratio to obtain a high flux density and a high thrust. The analysis is conducted through JMAG software and it is found that the optimum teeth ratio for both the stator and mover gives an increase of 94.4% increases compared to the 0.5mm stator and mover width.

  8. Fabrication and Analysis of Tapered Tip Silicon Microneedles for MEMS based Drug Delivery System

    Directory of Open Access Journals (Sweden)

    Muhammad Waseem Ashraf

    2010-11-01

    Full Text Available In this paper, a novel design of transdermal drug delivery (TDD system is presented. The proposed system consists of controlled electronic circuit and microelectromechanical system (MEMS based devices like microneedles, micropump, flow sensor, and blood pressure sensor. The aim of this project is to develop a system that can eliminate the limitations associated with oral therapy. In this phase tapered tip silicon microneedles have been fabricated using inductively coupled plasma (ICP etching technology. Using ANSYS, simulation of microneedles has been conducted before the fabrication process to test the design suitability for TDD. More over multifield analysis of reservoir integrated with microneedle array using piezoelectric actuator has also been performed. The effects of frequency and voltage on actuator and fluid flow rate through 6×6 microneedle array have been investigated. This work provides envisage data to design suitable devices for TDD.

  9. Risk Factors for Subsidence of a Modular Tapered Femoral Stem Used for Revision Total Hip Arthroplasty.

    Science.gov (United States)

    Tangsataporn, Suksan; Safir, Oleg A; Vincent, Alexander D; Abdelbary, Hesham; Gross, Allan E; Kuzyk, Paul R T

    2015-06-01

    The purpose of this study was to determine the incidence, and the clinical and radiographic risk factors for significant subsidence of a cementless, modular tapered revision femoral stem. Femoral stem subsidence of at least 10 mm or subsidence requiring revision was considered significant subsidence. Ninety-seven patients (99 hips) were included with minimum radiographic follow-up of one year (mean 34 months; range, 12-91 months). The mean stem subsidence was 4.5 mm (range, 0-44 mm). Fourteen out of 99 (14.1%) stems had significant subsidence and 6 (6.1%) stems required revision due to subsidence. Patient weight greater than 80 kg (P=0.04) and femoral stem press-fit distance of less than 2 cm (Psubsidence. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Optofluidic realization and retaining of cell-cell contact using an abrupt tapered optical fibre.

    Science.gov (United States)

    Xin, Hongbao; Zhang, Yao; Lei, Hongxiang; Li, Yayi; Zhang, Huixian; Li, Baojun

    2013-01-01

    Studies reveal that there exists much interaction and communication between bacterial cells, with parts of these social behaviors depending on cell-cell contacts. The cell-cell contact has proved to be crucial for determining various biochemical processes. However, for cell culture with relatively low cell concentration, it is difficult to precisely control and retain the contact of a small group of cells. Particularly, the retaining of cell-cell contact is difficult when flows occur in the medium. Here, we report an optofluidic method for realization and retaining of Escherichia coli cell-cell contact in a microfluidic channel using an abrupt tapered optical fibre. The contact process is based on launching a 980-nm wavelength laser into the fibre, E. coli cells were trapped onto the fibre tip one after another, retaining cell-cell contact and forming a highly organized cell chain. The formed chains further show the ability as bio-optical waveguides.

  11. Magnetic Field Sensing Based on Bi-Tapered Optical Fibers Using Spectral Phase Analysis

    Directory of Open Access Journals (Sweden)

    Luis A. Herrera-Piad

    2017-10-01

    Full Text Available A compact, magnetic field sensor system based on a short, bi-tapered optical fiber (BTOF span lying on a magnetic tape was designed, fabricated, and characterized. We monitored the transmission spectrum from a broadband light source, which displayed a strong interference signal. After data collection, we applied a phase analysis of the interference optical spectrum. We here report the results on two fabricated, BTOFs with different interference spectrum characteristics; we analyzed the signal based on the interference between a high-order modal component and the core fiber mode. The sensor exhibited a linear response for magnetic field increments, and we achieved a phase sensitivity of around 0.28 rad/mT. The sensing setup presented remote sensing operation and low-cost transducer magnetic material.

  12. Microwave sidebands for laser cooling by direct modulation of a tapered amplifier.

    Science.gov (United States)

    Mahnke, J; Kulas, S; Geisel, I; Jöllenbeck, S; Ertmer, W; Klempt, C

    2013-06-01

    Laser cooling of atoms usually necessitates several laser frequencies. Alkaline atoms, for example, are cooled by two lasers with a frequency difference in the gigahertz range. This gap cannot be closed with simple shifting techniques. Here, we present a method of generating sidebands at 6.6 GHz by modulating the current of a tapered amplifier, which is seeded by an unmodulated master laser. The sidebands enable trapping of 1.1 × 10(9) (87)Rb atoms in a chip-based magneto-optical trap. Compared to the direct modulation of the master laser, this method allows for an easy implementation, a fast adjustment over a wide frequency range, and the simultaneous extraction of unmodulated light for manipulation and detection. The low power consumption, small size, and applicability for multiple frequencies benefit a wide range of applications reaching from atom-based mobile sensors to the laser cooling of molecules.

  13. Tapered modular fluted titanium stems for femoral fixation in revision total knee arthroplasty.

    Science.gov (United States)

    Stambough, Jeffrey B; Mason, J Bohannon; Riesgo, Aldo M; Fehring, Thomas K

    2018-03-01

    Consensus regarding femoral stem fixation options in revision total knee arthroplasty remains controversial. Tapered, modular, fluted titanium (TMFT) stems have an excellent track record in total hip arthroplasty for their ability to provide axial and rotational stability in situations of compromised host bone. We present 3 successfully treated cases in which the Food & Drug Administration granted permission to use custom TMFT stems in situations of failed femoral fixation in multiple revised knees. These stems hold promise to achieve stable fixation in revision total knee arthroplasty where host metadiaphyseal bone is deficient. Implant manufactures should consider dedicating future resources to create adapters that can link existing successful TMFT stems currently used in hip arthroplasty to revision total knee components when host bone is severely compromised.

  14. ISR beam scrapers

    CERN Multimedia

    CERN PhotoLab

    1972-01-01

    Beam scrapers seen in the direction of the beam. The two horizontal scraper foils are near the centre of the beam pipe andthe two scrapers for protection of the vacuum chamber are further outside. In the lower part of the beam pipe is the vertical halo scraping blade.

  15. Telecommunication using muon beams

    International Nuclear Information System (INIS)

    Arnold, R.C.

    1976-01-01

    Telecommunication is effected by generating a beam of mu mesons or muons, varying a property of the beam at a modulating rate to generate a modulated beam of muons, and detecting the information in the modulated beam at a remote location

  16. Analysis of orthotropic beams

    Science.gov (United States)

    Jen Y. Liu; S. Cheng

    1979-01-01

    A plane-stress analysis of orthotropic or isotropic beams is presented. The loading conditions considered are: (1) a concentrated normal load arbitrarily located on the beam, and (2) a distributed normal load covering an arbitrary length of the beam. exhibit close agreement with existing experimental data from Sitka spruce beams. Other loading conditions can similarly...

  17. Telecommunication using muon beams

    Science.gov (United States)

    Arnold, Richard C.

    1976-01-01

    Telecommunication is effected by generating a beam of mu mesons or muons, varying a property of the beam at a modulating rate to generate a modulated beam of muons, and detecting the information in the modulated beam at a remote location.

  18. Low-loss saturable absorbers based on tapered fibers embedded in carbon nanotube/polymer composites

    Directory of Open Access Journals (Sweden)

    Amos Martinez

    2017-12-01

    Full Text Available The emergence of low-dimensional materials has opened new opportunities in the fabrication of compact nonlinear photonic devices. Single-walled carbon nanotubes were among the first of those materials to attract the attention of the photonics community owing to their high third order susceptibility, broadband operation, and ultrafast response. Saturable absorption, in particular, has become a widespread application for nanotubes in the mode-locking of a fiber laser where they are used as nonlinear passive amplitude modulators to initiate pulsed operation. Numerous approaches have been proposed for the integration of nanotubes in fiber systems; these can be divided into those that rely on direct interaction (where the nanotubes are sandwiched between fiber connectors and those that rely on lateral interaction with the evanescence field of the propagating wave. Tapered fibers, in particular, offer excellent flexibility to adjust the nonlinearity of nanotube-based devices but suffer from high losses (typically exceeding 50% and poor saturable to non-saturable absorption ratios (typically above 1:5. In this paper, we propose a method to fabricate carbon nanotube saturable absorbers with controllable saturation power, low-losses (as low as 15%, and large saturable to non-saturable loss ratios approaching 1:1. This is achieved by optimizing the procedure of embedding tapered fibers in low-refractive index polymers. In addition, this study sheds light in the operation of these devices, highlighting a trade-off between losses and saturation power and providing guidelines for the design of saturable absorbers according to their application.

  19. Low-loss saturable absorbers based on tapered fibers embedded in carbon nanotube/polymer composites

    Science.gov (United States)

    Martinez, Amos; Al Araimi, Mohammed; Dmitriev, Artemiy; Lutsyk, Petro; Li, Shen; Mou, Chengbo; Rozhin, Alexey; Sumetsky, Misha; Turitsyn, Sergei

    2017-12-01

    The emergence of low-dimensional materials has opened new opportunities in the fabrication of compact nonlinear photonic devices. Single-walled carbon nanotubes were among the first of those materials to attract the attention of the photonics community owing to their high third order susceptibility, broadband operation, and ultrafast response. Saturable absorption, in particular, has become a widespread application for nanotubes in the mode-locking of a fiber laser where they are used as nonlinear passive amplitude modulators to initiate pulsed operation. Numerous approaches have been proposed for the integration of nanotubes in fiber systems; these can be divided into those that rely on direct interaction (where the nanotubes are sandwiched between fiber connectors) and those that rely on lateral interaction with the evanescence field of the propagating wave. Tapered fibers, in particular, offer excellent flexibility to adjust the nonlinearity of nanotube-based devices but suffer from high losses (typically exceeding 50%) and poor saturable to non-saturable absorption ratios (typically above 1:5). In this paper, we propose a method to fabricate carbon nanotube saturable absorbers with controllable saturation power, low-losses (as low as 15%), and large saturable to non-saturable loss ratios approaching 1:1. This is achieved by optimizing the procedure of embedding tapered fibers in low-refractive index polymers. In addition, this study sheds light in the operation of these devices, highlighting a trade-off between losses and saturation power and providing guidelines for the design of saturable absorbers according to their application.

  20. Effect of Taper on Stress Distribution of All Ceramic Fixed Partial Dentures: a 3D-FEA Study

    Directory of Open Access Journals (Sweden)

    F. Gerami-Panah

    2005-09-01

    Full Text Available Statement of Problem: Mechanical failure of ceramic materials is controlled by brittle fracture, mostly occurred in tension. In 3-unit all-ceramic FPDs the connector area is considered to be at fracture risk because of tensile stress concentrations.Purpose: The aim of this FE analysis was to evaluate the effect of taper on stress distribution in all-ceramic FPDs.Materials and Methods: In this experimental study two 3-D finite element models of thee-unit IPS-Empress 2 FPDs replacing mandible second premolar were created by means of finite element software. The digital images were obtained from CT scan of human skull. Abutment was reduced with 12 and 22 degrees of taper. The cement layer,PDL, cancellous bone and cortical bone were also modeled. Frameworks of core material were fabricated. A static load of 100 N was applied at mid pontic area.Resolved stresses were calculated according to the Von Mises criterion and principal stresses.Results: In both models stresses were concentrated at the connectors. The maximum stresses were lower in the model with larger taper. The maximum Von Mises stress was recorded at the connector region of the premolar and the pontic. In model with larger taper the patterns of stresses were also more distributed and less concentrated.Conclusion: The highest Von Mises and principal stress were recorded at the connectors. Tensile stresses developed at the gingival connector of premolar and pontic was higher than molar. The stress level in model with 22-degree taper was lower compare to 12-degree and the stress pattern was more distributed, lowered the risk ofconcentrations.

  1. LANSCE beam current limiter

    International Nuclear Information System (INIS)

    Gallegos, F.R.

    1996-01-01

    The Radiation Security System (RSS) at the Los Alamos Neutron Science Center (LANSCE) provides personnel protection from prompt radiation due to accelerated beam. Active instrumentation, such as the Beam Current Limiter, is a component of the RSS. The current limiter is designed to limit the average current in a beam line below a specific level, thus minimizing the maximum current available for a beam spill accident. The beam current limiter is a self-contained, electrically isolated toroidal beam transformer which continuously monitors beam current. It is designed as fail-safe instrumentation. The design philosophy, hardware design, operation, and limitations of the device are described

  2. The beam dump tunnels

    CERN Multimedia

    Patrice Loïez

    2002-01-01

    In these images workers are digging the tunnels that will be used to dump the counter-circulating beams. Travelling just a fraction under the speed of light, the beams at the LHC will each carry the energy of an aircraft carrier travelling at 12 knots. In order to dispose of these beams safely, a beam dump is used to extract the beam and diffuse it before it collides with a radiation shielded graphite target.

  3. Ion beam diagnosis

    International Nuclear Information System (INIS)

    Strehl, P.

    1994-04-01

    This report is an introduction to ion beam diagnosis. After a short description of the most important ion beam parameters measurements of the beam current by means of Faraday cups, calorimetry, and beam current transformers and measurements of the beam profile by means of viewing screens, profile grids and scanning devices, and residual gas ionization monitors are described. Finally measurements in the transverse and longitudinal phase space are considered. (HSI)

  4. On-line electron beam measurements for the Los Alamos Free-Electron Laser

    International Nuclear Information System (INIS)

    Lumpkin, A.H.; Feldman, R.B.; Feldman, D.W.; Stein, W.E.

    1987-01-01

    Recent developments in the electron beam diagnostics used on the Los Alamos Free-Electron Laser (FEL) have extended our on-line, quantitative analysis capability to extraction efficiency and micropulse temporal duration. The FEL's 20-MeV electron beam is 100 μs in length and consists of ∼2000 micropulses of 20-ps duration and 46-ns separation. This extreme range of time scales is addressed by employing a combination of synchronized beam deflectors, an electron spectrometer, intensified video cameras, real-time video digitizers, and microcomputers. The tapered wiggler result for extraction efficiency (2%) and results for pulse duration measurements (10 to 15 ps) by two techniques are presented

  5. Beam dynamics analysis of femtosecond microbunches produced by the staged electron laser acceleration experiment

    Directory of Open Access Journals (Sweden)

    F. Zhou

    2003-05-01

    Full Text Available Preservation of the femtosecond (fs microbunches, created during laser acceleration, is a crucial step to enable staging of the laser acceleration process. This paper focuses on the optimization of the beam dynamics of fs microbunches transported through the staged electron laser acceleration (STELLA-II experiment being carried out at the Brookhaven National Laboratory Accelerator Test Facility. STELLA-II consists of an inverse free electron laser (IFEL untapered undulator, which acts as an electron beam energy modulator; a magnetic chicane, which acts as a buncher; a second IFEL tapered undulator, which acts as an accelerator; and a dipole, which serves as an energy spectrometer. When the energy-modulated macrobunch traverses through the chicane and a short drift space, microbunches of order fs in duration (i.e., ∼3  fs FWHM are formed. The 3-fs microbunches are accelerated by interacting with a high-power CO_{2} laser beam in the following tapered undulator. These extremely short microbunches may experience significant space charge and coherent synchrotron radiation effects when traversing the STELLA-II transport line. These effects are analyzed and the safe operating conditions are determined. With less than 0.5-pC microbunch charge, both microbunch debunching and emittance growth are negligible, and the energy-spread increase is less than 5%. These results are also useful for the laser electron acceleration project at SLAC and in possible future programs where the fs microbunches are employed for other purposes.

  6. Beam diagnostics for low energy beams

    Directory of Open Access Journals (Sweden)

    J. Harasimowicz

    2012-12-01

    Full Text Available Low-energetic ion and antimatter beams are very attractive for a number of fundamental studies. The diagnostics of such beams, however, is a challenge due to low currents down to only a few thousands of particles per second and significant fraction of energy loss in matter at keV beam energies. A modular set of particle detectors has been developed to suit the particular beam diagnostic needs of the ultralow-energy storage ring (USR at the future facility for low-energy antiproton and ion research, accommodating very low beam intensities at energies down to 20 keV. The detectors include beam-profile monitors based on scintillating screens and secondary electron emission, sensitive Faraday cups for absolute intensity measurements, and capacitive pickups for beam position monitoring. In this paper, the design of all detectors is presented in detail and results from beam measurements are shown. The resolution limits of all detectors are described and options for further improvement summarized. Whilst initially developed for the USR, the instrumentation described in this paper is also well suited for use in other low-intensity, low-energy accelerators, storage rings, and beam lines.

  7. A Large Aperture UWB Antenna Array for Real Beam Radar Imaging

    OpenAIRE

    Liao, Chao-Hsiang; Chang, Dau-Chyrh

    2012-01-01

    The development of four-element ultra-wideband (UWB) comb taper slot antenna array with 18 cm element spacing for real beam radar imaging is described. The four-element UWB array system with optimum element spacing is analyzed by energy pattern. A wideband double ridge horn antenna is used as the transmitting antenna, the developed large aperture UWB array is used as the receiving antenna. The transmitting antenna and the receiving antenna are combined with impulse time domain measurement sys...

  8. Revisit of combined parallel-beam/cone-beam or fan-beam/cone-beam imaging.

    Science.gov (United States)

    Zeng, Gengsheng L

    2013-10-01

    This aim of this paper is to revisit the parallel-beam/cone-beam or fan-beam/cone-beam imaging configuration, and to investigate whether this configuration has any advantages. Twenty years ago, it was suggested to simultaneously use a parallel-beam (or a fan-beam) collimator and a cone-beam collimator to acquire single photon emission computed tomography data. The motivation was that the parallel-beam (or the fan-beam) collimator can provide sufficient sampling, while the cone-beam collimator is able to provide higher photon counts. Even with higher total counts, this hybrid system does not give significant improvement (if any) in terms of image noise and artifacts reduction. If a conventional iterative maximum-likelihood expectation-maximization algorithm is used to reconstruct the image, the resultant reconstruction may be worse than the parallel-beam-only (or fan-beam-only) system. This paper uses the singular value decomposition (SVD) analysis to explain this phenomenon. The SVD results indicate that the parallel-beam-only and the fan-beam-only system outperform the combined systems. The optimal imaging system does not necessary to be the one that generates the projections with highest signal-to-noise ratio and best resolution.

  9. A comparative evaluation of root canal area increase using three different nickel-titanium rotary systems: An ex vivo cone-beam computed tomographic analysis.

    Science.gov (United States)

    Deka, Adrija; Bhuyan, A C; Bhuyan, Darpana

    2015-01-01

    The present study was undertaken to compare and evaluate the area increase of root canals with ProTaper, iRaCe and Revo-S systems using cone beam computed tomography for analysis. Forty five extracted human mandibular premolars having single canal and straight root were collected. Teeth were randomly assigned to three groups (n=15). Samples were decoronized by maintaining root length at 14 mm. Pre-instrumentation cone beam computed tomography scan was done after stabilizing the samples on wax blocks. The working length was determined at 1 mm short from the apical foramen by using a ISO 15 K-file tip protruding at apical foramen. Preparation was carried out according to the manufacturer's instructions. Finally, canals were instrumented upto 30/.06 apically for each group. After each instrumentation, root canals were irrigated with 2ml of 3% sodium hypochlorite solution followed by 2 ml of 17% EDTA solution. Final irrigation was done with 5ml of saline. Post instrumentation cone beam computed tomography scans of all samples in the 3 groups were acquired. Mean percentage of area increase in different thirds of the canal was highest for ProTaper followed by i-RaCe and Revo-s system which was statistically significant. Root canal area increase was highest for ProTaper followed by i-Race and Revo-S systems.

  10. A comparative evaluation of root canal area increase using three different nickel-titanium rotary systems: An ex vivo cone-beam computed tomographic analysis

    Directory of Open Access Journals (Sweden)

    Adrija Deka

    2015-01-01

    Full Text Available Background and Objectives: The present study was undertaken to compare and evaluate the area increase of root canals with ProTaper, iRaCe and Revo-S systems using cone beam computed tomography for analysis. Materials and Methodology: Forty five extracted human mandibular premolars having single canal and straight root were collected. Teeth were randomly assigned to three groups (n=15. Samples were decoronized by maintaining root length at 14 mm. Pre-instrumentation cone beam computed tomography scan was done after stabilizing the samples on wax blocks. The working length was determined at 1 mm short from the apical foramen by using a ISO 15 K-file tip protruding at apical foramen. Preparation was carried out according to the manufacturer′s instructions. Finally, canals were instrumented upto 30/.06 apically for each group. After each instrumentation, root canals were irrigated with 2ml of 3% sodium hypochlorite solution followed by 2 ml of 17% EDTA solution. Final irrigation was done with 5ml of saline. Post instrumentation cone beam computed tomography scans of all samples in the 3 groups were acquired. Results: Mean percentage of area increase in different thirds of the canal was highest for ProTaper followed by i-RaCe and Revo-s system which was statistically significant. Interpretation and Conclusion: Root canal area increase was highest for ProTaper followed by i-Race and Revo-S systems.

  11. Low current beam techniques

    Energy Technology Data Exchange (ETDEWEB)

    Saint, A.; Laird, J.S.; Bardos, R.A.; Legge, G.J.F. [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Nishijima, T.; Sekiguchi, H. [Electrotechnical Laboratory, Tsukuba (Japan).

    1993-12-31

    Since the development of Scanning Transmission Microscopy (STIM) imaging in 1983 many low current beam techniques have been developed for the scanning (ion) microprobe. These include STIM tomography, Ion Beam Induced Current, Ion Beam Micromachining and Microlithography and Ionoluminense. Most of these techniques utilise beam currents of 10{sup -15} A down to single ions controlled by beam switching techniques This paper will discuss some of the low beam current techniques mentioned above, and indicate, some of their recent applications at MARC. A new STIM technique will be introduced that can be used to obtain Z-contrast with STIM resolution. 4 refs., 3 figs.

  12. Beam Dynamics and Beam Losses - Circular Machines

    CERN Document Server

    Kain, V

    2016-01-01

    A basic introduction to transverse and longitudinal beam dynamics as well as the most relevant beam loss mechanisms in circular machines will be presented in this lecture. This lecture is intended for physicists and engineers with little or no knowledge of this subject.

  13. T10 Beam Studies & Beam Simulation

    CERN Document Server

    Bergmann, Michael Georges; Van Dijk, Maarten; CERN. Geneva. EN Department

    2017-01-01

    In order to test detector components before their installation in actual experiments, one uses test beams in which one can control particle typ, momentum and size to high degree. For this project the focus of a secondary beam at T10 in the East Area at CERN was analysed using an AZALEA telescope from DESY.

  14. Fatigue and Damage Tolerance Analysis of a Hybrid Composite Tapered Flexbeam

    Science.gov (United States)

    Murri, Gretchen B.; Schaff, Jeffrey R.; Dobyns, Al

    2001-01-01

    The behavior of nonlinear tapered composite flexbeams under combined axial tension and cyclic bending loading was studied using coupon test specimens and finite element (FE) analyses. The flexbeams used a hybrid material system of graphite/epoxy and glass/epoxy and had internal dropped plies, dropped in an overlapping stepwise pattern. Two material configurations, differing only in the use of glass or graphite plies in the continuous plies near the midplane, were studied. Test specimens were cut from a full-size helicopter tail-rotor flexbeam and were tested in a hydraulic load frame under combined constant axialtension load and transverse cyclic bending loads. The first determination damage observed in the specimens occurred at the area around the tip of the outermost ply-drop group in the tapered region of the flexbeam, near the thick end. Delaminations grew slowly and stably, toward the thick end of the flexbeam, at the interfaces above and below the dropped-ply region. A 2D finite element model of the flexbeam was developed. The model was analyzed using a geometrically non-linear analysis with both the ANSYS and ABAQUS FE codes. The global responses of each analysis agreed well with the test results. The ANSYS model was used to calculate strain energy release rates (G) for delaminations initiating at two different ply-ending locations. The results showed that delaminations were more inclined to grow at the locations where they were observed in the test specimens. Both ANSYS and ABAQUS were used to calculate G values associated with delamination initiating at the observed location but growing in different interfaces, either above or below the ply-ending group toward the thick end, or toward the thin end from the tip of the resin pocket. The different analysis codes generated the same trends and comparable peak values, within 5-11 % for each delamination path. Both codes showed that delamination toward the thick region was largely mode II, and toward the thin

  15. BEAMS3D Neutral Beam Injection Model

    Energy Technology Data Exchange (ETDEWEB)

    Lazerson, Samuel

    2014-04-14

    With the advent of applied 3D fi elds in Tokamaks and modern high performance stellarators, a need has arisen to address non-axisymmetric effects on neutral beam heating and fueling. We report on the development of a fully 3D neutral beam injection (NBI) model, BEAMS3D, which addresses this need by coupling 3D equilibria to a guiding center code capable of modeling neutral and charged particle trajectories across the separatrix and into the plasma core. Ionization, neutralization, charge-exchange, viscous velocity reduction, and pitch angle scattering are modeled with the ADAS atomic physics database [1]. Benchmark calculations are presented to validate the collisionless particle orbits, neutral beam injection model, frictional drag, and pitch angle scattering effects. A calculation of neutral beam heating in the NCSX device is performed, highlighting the capability of the code to handle 3D magnetic fields.

  16. Successful Beam-Beam Tuneshift Compensation

    Energy Technology Data Exchange (ETDEWEB)

    Bishofberger, Kip Aaron [Univ. of California, Los Angeles, CA (United States)

    2005-01-01

    The performance of synchrotron colliders has been limited by the beam-beam limit, a maximum tuneshift that colliding bunches could sustain. Due to bunch-to-bunch tune variation and intra-bunch tune spread, larger tuneshifts produce severe emittance growth. Breaking through this constraint has been viewed as impossible for several decades. This dissertation introduces the physics of ultra-relativistic synchrotrons and low-energy electron beams, with emphasis placed on the limits of the Tevatron and the needs of a tuneshift-compensation device. A detailed analysis of the Tevatron Electron Lens (TEL) is given, comparing theoretical models to experimental data whenever possible. Finally, results of Tevatron operations with inclusion of the TEL are presented and analyzed. It is shown that the TEL provides a way to shatter the previously inescapable beam-beam limit.

  17. Cryogenic atomic beam source at VEPP-3

    International Nuclear Information System (INIS)

    Isaeva, L. G.; Lazarenko, B. A.; Mishnev, S. I.; Nikolenko, D. M.; Popov, S. G.; Rachek, I. A.; Shestakov, Yu. V.; Toporkov, D. K.; Vesnovsky, D. K.; Zevakov, S. A.; Osipov, A. N.; Sidorov, A. A.; Stibunov, V. N.

    1998-01-01

    The experiment on elastic and inelastic scattering of 2 GeV electrons by internal polarized target is in progress at the VEPP-3 storage ring in Novosibirsk. It's carried out by Novosibirsk/St.-Petersburg/Tomsk/Argonne/Illinois/NIKHEF collaboration. A cryogenic Atomic Beam Source having five superconducting sextupoles is under manufacturing to feed by polarized deuterium atoms an internal storage cell target. All the magnets have been manufactured and tested. The magnetic poletip field up to 4.8 T was measured at the cylindrical magnets having 44 mm inner diameter while 3.1 T and 4.0 T were measured for the tapered magnets. The dissociation degree of about 90% has been achieved for a gas throughput 1 mbx1/sec. The expected flux of polarized deuterium atoms into the storage cell is 1.0x10 17 at/sec (in two substrates). The geometry of the magnetic system, results on the dissociation measurements, testing of the superconducting magnet and expected parameters of the target are presented

  18. Cryogenic atomic beam source at VEPP-3

    Science.gov (United States)

    Isaeva, L. G.; Lazarenko, B. A.; Mishnev, S. I.; Nikolenko, D. M.; Osipov, A. N.; Popov, S. G.; Rachek, I. A.; Shestakov, Yu. V.; Sidorov, A. A.; Stibunov, V. N.; Toporkov, D. K.; Vesnovsky, D. K.; Zevakov, S. A.

    1998-01-01

    The experiment on elastic and inelastic scattering of 2 GeV electrons by internal polarized target is in progress at the VEPP-3 storage ring in Novosibirsk. It's carried out by Novosibirsk/St.-Petersburg/Tomsk/Argonne/Illinois/NIKHEF collaboration. A cryogenic Atomic Beam Source having five superconducting sextupoles is under manufacturing to feed by polarized deuterium atoms an internal storage cell target. All the magnets have been manufactured and tested. The magnetic poletip field up to 4.8 T was measured at the cylindrical magnets having 44 mm inner diameter while 3.1 T and 4.0 T were measured for the tapered magnets. The dissociation degree of about 90% has been achieved for a gas throughput 1 mb×1/sec. The expected flux of polarized deuterium atoms into the storage cell is 1.0×1017 at/sec (in two substrates). The geometry of the magnetic system, results on the dissociation measurements, testing of the superconducting magnet and expected parameters of the target are presented.

  19. Spectral tunability of two-photon states generated by spontaneous four-wave mixing: fibre tapering, temperature variation and longitudinal stress

    Science.gov (United States)

    Ortiz-Ricardo, E.; Bertoni-Ocampo, C.; Ibarra-Borja, Z.; Ramirez-Alarcon, R.; Cruz-Delgado, D.; Cruz-Ramirez, H.; Garay-Palmett, K.; U'Ren, A. B.

    2017-09-01

    We explore three different mechanisms designed to controllably tune the joint spectrum of photon pairs produced by the spontaneous four-wave mixing (SFWM) process in optical fibres. The first of these is fibre tapering, which exploits the modified optical dispersion resulting from reducing the core radius. We have presented a theory of SFWM for tapered fibres, as well as experimental results for the SFWM coincidence spectra as a function of the reduction in core radius due to tapering. The other two techniques that we have explored are temperature variation and application of longitudinal stress. While the maximum spectral shift observed with these two techniques is smaller than for fibre tapering, they are considerably simpler to implement and have the important advantage that they are based on the use of a single, suitably controlled, fibre specimen.

  20. Strong light-extraction enhancement in GaInN light-emitting diodes patterned with TiO2 micro-pillars with tapered sidewalls

    Science.gov (United States)

    Ma, Ming; Cho, Jaehee; Fred Schubert, E.; Park, Yongjo; Bum Kim, Gi; Sone, Cheolsoo

    2012-10-01

    An effective method to enhance the light extraction for GaInN light-emitting diodes (LEDs) is reported. The method employs TiO2 micro-pillars with tapered sidewalls, which are refractive-index-matched to the underlying GaN. The tapered micro-pillars are fabricated by using reflowed photoresist as mask during CHF3-based dry etch, with O2 added in order to precisely control the taper angle. LEDs patterned with TiO2 micro-pillars with tapered sidewalls show a 100% enhancement in light-output power over planar reference LEDs. The measured results are in good agreement with ray-tracing simulations, showing strong potential of optical surfaces that are controlled in terms of refractive index and lateral structure.

  1. Beam Loss in Linacs

    CERN Document Server

    Plum, M.A.

    2016-01-01

    Beam loss is a critical issue in high-intensity accelerators, and much effort is expended during both the design and operation phases to minimize the loss and to keep it to manageable levels. As new accelerators become ever more powerful, beam loss becomes even more critical. Linacs for H- ion beams, such as the one at the Oak Ridge Spallation Neutron Source, have many more loss mechanisms compared to H+ (proton) linacs, such as the one being designed for the European Spallation Neutron Source. Interesting H- beam loss mechanisms include residual gas stripping, H+ capture and acceleration, field stripping, black-body radiation and the recently discovered intra-beam stripping mechanism. Beam halo formation, and ion source or RF turn on/off transients, are examples of beam loss mechanisms that are common for both H+ and H- accelerators. Machine protection systems play an important role in limiting the beam loss.

  2. Beam scanning system

    International Nuclear Information System (INIS)

    Enge, H.A.

    1977-01-01

    A system for deflecting a beam of particles having different momenta, preferably through a 90 0 angle, so as to cause the beam to impinge upon a moving target and to scan across the target is described. The system includes a means responsive to a beam from a suitable source for causing the beam to periodically scan in a scanning plane and further means for deflecting the periodically scanned beam through the desired angle in a deflection plane so that the deflected beam impinges on the target. Means are included in the system for reducing the momentum dispersion at the target in both the deflection and the scanning planes and for spatially focussing the beam so as to produce a desired beam diameter at the target

  3. Impact of clinical pharmacists' recommendations on a proton pump inhibitor taper protocol in an ambulatory care practice.

    Science.gov (United States)

    Bundeff, Andrew W; Zaiken, Kathy

    2013-05-01

    Previous studies have demonstrated an association between chronic proton pump inhibitor (PPI) utilization and adverse events such as fractures, infections, hypomagnesemia, and vitamin B12 deficiency. Because patients taking PPIs for an extended period of time are more susceptible to these adverse events, an approach to tapering patients off PPIs is clinically warranted. To evaluate the impact of clinical pharmacists' recommendations to clinicians to decrease PPI use in patients when chronic therapy is not indicated. Clinical pharmacists electronically sent PPI taper recommendations for qualifying patients to primary care providers the day before each patient's appointment. Using insurance claims data, an average pills per month (PPM) count was calculated for the 5-month period prior to initiating the PPI taper as well as for the 5-month period after the date of taper initiation. The PPM count was calculated by dividing the total number of pills a patient received by the total number of days in that period, multiplied by 30. The primary outcome for the study was the change in average PPM count from baseline (pretaper period) to follow-up (posttaper period) and was assessed using a paired t-test. Secondary outcomes included change in total annualized PPI costs to the organization, proportion of patients who began the taper protocol after primary care provider recommendation, and whether baseline characteristics were predictors of successful response. Change in annualized PPI costs to the organization was calculated by multiplying the average unit cost per pill (determined using a weighted average of the average wholesale price of the individual drugs) by the PPM change seen with the primary outcome and by the number of patients included in the study and expressed over the period of a full year. Logistic regression analysis was used to determine whether baseline variables including alcohol and tobacco use, diagnosis related to PPI use, PPI dose, dosing frequency

  4. Effect of magnetic field on peristaltic flow of a fourth grade fluid in a tapered asymmetric channel

    Directory of Open Access Journals (Sweden)

    M. Kothandapani

    2018-01-01

    Full Text Available The problem of peristaltic transport of an incompressible non-Newtonian fluid in a tapered asymmetric channel is debated under long-wavelength and low-Reynolds number assumptions. The fluid is considered to be fourth order and electrically conducting by a transverse magnetic field. The tapered asymmetry in the flow is induced by taking peristaltic wave imposed on the non uniform boundary walls to possess different amplitudes and phase. Series solutions for stream function, axial velocity and pressure gradient are given using regular perturbation technique, when Deborah number is small. Numerical computations have been performed for the pressure rise per wavelength. Influences of different physical parameters entering into the problem have also been discussed in detail.

  5. Effective Synthesis and Recovery of Silver Nanowires Prepared by Tapered Continuous Flow Reactor for Flexible and Transparent Conducting Electrode

    Directory of Open Access Journals (Sweden)

    Hyung Duk Yun

    2016-01-01

    Full Text Available Silver nanowires (AgNWs with high aspect ratio were obtained utilizing a tapered tubular reactor by the polyol process. The tapered tubular type flow reactor allowed us to obtain nanowires in high yield without defects that is generally encountered in a closed reactor due to excessive shearing for a long time. After reaction the AgNWs were precipitated in the aqueous solution with the aid of a hydrogen bond breaker and were recovered effectively without using a high-cost centrifugation process. Dispersion of the AgNWs were used to prepare transparent conducting electrode (TCE films by a spray coating method, which showed 86% transmittance and 90 Ωsq−1 sheet resistance.

  6. Revision Total Hip Arthroplasty Using a Modular Tapered Stem With Distal Fixation Good Short-Term Results in 125 Revisions

    DEFF Research Database (Denmark)

    Ovesen, Ole; Emmeluth, Claus; Hofbauer, Christian

    2009-01-01

    After 2 to 7 years we reviewed 125 prosthetic hip arthroplasty stem revisions using a modular tapered stem with distal fixation. Median age of these patients was 68 (33-92) years. Baseline and follow-up data were registered prospectively according to the Danish Hip Arthroplasty Registry. Survival...... system is very versatile, can be used in most femoral revision cases, and allows rapid bone remodeling. We did not find an increased number of complications compared to the literature. Further long-term follow-up, however, is essential......., free of any rerevision, was 94%. Harris Hip Score improved from average 44 to 85. Bony regeneration was an early and significant finding in most cases. Complications included 4 (3%) fractures intraoperatively and 8 (6%) dislocations, 4 (3%) deep infections, and 1 (1%) stem fracture. This modular taper...

  7. Growth of tapered silica nanowires with a shallow U-shaped vapor chamber: Growth mechanism and structural and optical properties

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Danqing; Zhang, Xi, E-mail: xizhang@scu.edu.cn; Wei, Jianglin; Gu, Gangxu; Xiang, Gang, E-mail: gxiang@scu.edu.cn [Department of Physics, Sichuan University, Chengdu 610064 (China); Key Laboratory of High Energy Density Physics and Technology of Ministry of Education, Sichuan University, Chengdu 610064 (China)

    2015-04-28

    Traditional chemical vapor deposition method modified with a shallow U-shaped vapor chamber has been used to synthesize tapered bamboo shoot-like (BS-like) amorphous SiO{sub 2} nanowires (NWs) on Si (100) substrates without catalyst. The key innovation of this approach lies in a creation of swirling flow of the reactant vapors during the growth, which leads to a harvest of tapered silica NWs with lengths up to several microns. The unique structures and corresponding luminescence properties of the BS-like NWs were studied and their relationship with the evaporated active reactants was explored. A thermodynamic model that considers the critical role of the vapor flow during the growth is proposed to understand the structural and optical features. The shallow U-shaped vapor chamber-aided approach may provide a viable way to tailor novel structure of NWs for potential applications in nano-devices.

  8. Growth of tapered silica nanowires with a shallow U-shaped vapor chamber: Growth mechanism and structural and optical properties

    Science.gov (United States)

    Zhang, Danqing; Zhang, Xi; Wei, Jianglin; Gu, Gangxu; Xiang, Gang

    2015-04-01

    Traditional chemical vapor deposition method modified with a shallow U-shaped vapor chamber has been used to synthesize tapered bamboo shoot-like (BS-like) amorphous SiO2 nanowires (NWs) on Si (100) substrates without catalyst. The key innovation of this approach lies in a creation of swirling flow of the reactant vapors during the growth, which leads to a harvest of tapered silica NWs with lengths up to several microns. The unique structures and corresponding luminescence properties of the BS-like NWs were studied and their relationship with the evaporated active reactants was explored. A thermodynamic model that considers the critical role of the vapor flow during the growth is proposed to understand the structural and optical features. The shallow U-shaped vapor chamber-aided approach may provide a viable way to tailor novel structure of NWs for potential applications in nano-devices.

  9. Tests of Round and Flat Spoilers on a Tapered Wing in the NACA 19-Foot Pressure Wind Tunnel

    Science.gov (United States)

    Wenzinger, Carl J; Bowen, John D

    1941-01-01

    Several arrangements of round and flat spanwise spoilers attached to the upper surface of a tapered wing were tested in the NACA 19-foot pressure wind tunnel to determine the most effective type, location, and size of spoiler necessary to reduce greatly the lift on the wings of large flying boats when moored. The effect of the various spoilers on the lift, the drag, and the pitching-moment characteristics of the tapered wing was measured over a range of angles of attack from zero to maximum lift. The most effective type of spoiler was found to be the flat type with no space between it and the wing surface. The chordwise location of such a spoiler was not critical within the range investigated, from 5 to 20 percent of the wing chord from the leading edge.

  10. High-temperature sensor based on an abrupt-taper Michelson interferometer in single-mode fiber.

    Science.gov (United States)

    Xu, Le; Jiang, Lan; Wang, Sumei; Li, Benye; Lu, Yongfeng

    2013-04-01

    This study proposes a high-temperature sensor based on an abrupt fiber-taper Michelson interferometer (FTMI) in single-mode fiber fabricated by a fiber-taper machine and electric-arc discharge. The proposed FTMI is applied to measure temperature and refractive index (RI). A high temperature sensitivity of 118.6 pm/°C is obtained in the temperature range of 500°C-800°C. The wavelength variation is only -0.335 nm for the maximum attenuation peak, with the external RI changed from 1.333 to 1.3902, which is desirable for high-temperature sensing to eliminate the cross sensitivity to RI.

  11. Crossed beam experiments

    International Nuclear Information System (INIS)

    Dolder, K.T.

    1976-01-01

    Many natural phenomena can only be properly understood if one has a detailed knowledge of interactions involving atoms, molecules, ions, electrons or photons. In the laboratory these processes are often studied by preparing beams of two types of particle and observing the reactions which occur when the beams intersect. Some of the more interesting of these crossed beam experiments and their results are discussed. Proposals to extend colliding beam techniques to high energy particle physics are also outlined. (author)

  12. Influence of heat treatment on cyclic fatigue and cutting efficiency of ProTaper Universal F2 instruments

    Directory of Open Access Journals (Sweden)

    Chih-Wen Chi

    2017-03-01

    Conclusion: Although 600°C treatment increased resistance to cyclic fatigue, it reduced the cutting efficiency of the files. The 400°C treatment maintained the cutting ability and prolonged the cyclic fatigue life of the files. Therefore, for clinical use of ProTaper Universal F2 files, 400°C pretreatment is a better choice than 600°C pretreatment.

  13. A randomized controlled clinical trial of two types of tapered implants on immediate loading in the posterior maxilla and mandible.

    Science.gov (United States)

    Kim, Young-Kyun; Lee, Jong-Ho; Lee, Ji-Young; Yi, Yang-Jin

    2013-01-01

    The aim of this study was to compare clinical outcomes and stability following immediate loading of two types of tapered implants in the partially edentulous posterior maxilla and mandible. A randomized controlled trial with 1 year of follow-up was performed on participants missing two consecutive teeth in a posterior quadrant with tapered implants with a hybrid textured surface. Group 1 received Osstem TSIII HA implants, and group 2 received Zimmer TSV implants. Group 1 implants were 4.5 or 5.0 mm in diameter, and group 2 implants were 4.7 mm in diameter; all implants were 10 mm long. Subjects received provisional restorations within 48 hours. Definitive restorations were provided 3 months (mandible) or 6 months (maxilla) later. Outcome measures were survival and success rates, marginal bone level change, implant stability quotient, and peri-implant soft tissue indices. Fifty participants completed the trial (group 1: 52 implants in 26 patients; group 2: 48 implants in 24 patients). The success rates were similar--98.1% in group 1 and 97.9% in group 2--at 12 months after immediate loading, but marginal bone loss was significantly different according to the implant design. Implant stability increased significantly in both arches. There were no significant differences in soft tissue indices between implant systems. If high primary stability is acquired, tapered implants with hybrid textured surfaces are predictable for immediate loading in the posterior maxilla and mandible. In spite of the influence of implant design on marginal bone loss, all tapered implants showed successful clinical outcomes and stability in immediate loading.

  14. An Electromagnetic Beam Converter

    DEFF Research Database (Denmark)

    2009-01-01

    The present invention relates to an electromagnetic beam converter and a method for conversion of an input beam of electromagnetic radiation having a bell shaped intensity profile a(x,y) into an output beam having a prescribed target intensity profile l(x',y') based on a further development...

  15. Beams 92: Proceedings

    International Nuclear Information System (INIS)

    Mosher, D.; Cooperstein, G.

    1993-01-01

    This report contains papers on the following topics: Ion beam papers; electron beam, bremsstrahlung, and diagnostics papers; radiating Z- pinch papers; microwave papers; electron laser papers; advanced accelerator papers; beam and pulsed power applications papers; pulsed power papers; and these papers have been indexed separately elsewhere

  16. The Polar Fluid Model for Blood Flow through a Tapered Artery with Overlapping Stenosis: Effects of Catheter and Velocity Slip

    Directory of Open Access Journals (Sweden)

    J. V. Ramana Reddy

    2015-01-01

    Full Text Available The blood flow through an overlapping clogged tapered artery in the presence of catheter is discussed. Since cholesterol deposition is resulting in the stenosis formation, velocity slip at the arterial wall is considered. The equations governing the fluid flow have been solved analytically under the assumption of the mild stenosis. The analysis with respect to various parameters arising out of fluid and geometry considered, on physiological parameters such as impedance and wall shear stress at the maximum height of the stenosis as well as across the entire length of the stenosis has been reported. A table summarizing the locations of extreme heights and the corresponding annular radii is provided. It is observed that the wall shear stress is the same at both the locations corresponding to the maximum height of the stenosis in case of nontapered artery while it varies in case of tapered artery. It is also observed that slip velocity and diverging tapered artery facilitate the fluid flow. Shear stress at the wall is increasing as micropolar parameter is decreasing and the trend is reversed in case of coupling number. The results obtained are validated by comparing them with the experimental and theoretical results.

  17. Efficacy of ProTaper retreatment system in root canals filled with gutta-percha and two endodontic sealers.

    Science.gov (United States)

    Só, Marcus Vinícius Reis; Saran, Caroline; Magro, Miriam Lago; Vier-Pelisser, Fabiana Vieira; Munhoz, Marcelo

    2008-10-01

    This study evaluated the efficacy of ProTaper Universal rotary retreatment system and hand files for filling material removal during retreatment and the influence of sealer type on the presence of filling debris in the reinstrumented canals. The canals of 60 palatal roots of first molars were obturated with gutta-percha and either a zinc oxide-eugenol-based or a resin-based sealer and reinstrumented: G1, EndoFill/hand files; G2, AH Plus/hand files; G3, EndoFill/ProTaper; G4, AH Plus/ProTaper. Roots were cleaved and examined with an optical microscope, and the amount of filling debris on canal walls was analyzed on digitized images. There was no significant difference (P > .05) among the root canal thirds within each group. G3 presented significantly more filling debris than G1 in the cervical third (P = .04). In the middle third, G2/G3/G4 showed more debris than G1 (P = .03). The techniques were similar (P = .64) in the apical third. All groups presented filling debris in the 3 canal thirds after reinstrumentation.

  18. Energy consumption of ProTaper Next X1 after glide path with PathFiles and ProGlider.

    Science.gov (United States)

    Berutti, Elio; Alovisi, Mario; Pastorelli, Michele Angelo; Chiandussi, Giorgio; Scotti, Nicola; Pasqualini, Damiano

    2014-12-01

    Instrument failure caused by excessive torsional stress can be controlled by creating a manual or mechanical glide path. The ProGlider single-file system (Dentsply Maillefer, Ballaigues, Switzerland) was recently introduced to perform a mechanical glide path. This study was designed to compare the effect of a glide path performed with PathFiles (Dentsply Maillefer) and ProGlider on torque, time, and pecking motion required for ProTaper Next X1 (Dentsply Maillefer) to reach the full working length in simulated root canals. Forty Endo Training Blocks (Dentsply Maillefer) were used. Twenty were prepared with a mechanical glide path using PathFiles 1 and 2 (the PathFile group), and 20 were prepared with a mechanical glide path using a ProGlider single file (the ProGlider group). All samples were shaped with ProTaper Next X1 driven by an endodontic motor connected to a digital wattmeter. The required torque for root canal instrumentation was analyzed by evaluating the electrical power consumption of the endodontic engine. Electric power consumption (mW/h), elapsed time (seconds), and number of pecking motions required to reach the full working length with ProTaper Next X1 were calculated. Differences among groups were analyzed with the parametric Student t test for independent data (P path and preliminary middle and coronal preflaring. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  19. Efficiency of the Self Adjusting File, WaveOne, Reciproc, ProTaper and hand files in root canal debridement

    Science.gov (United States)

    Topcu, K. Meltem; Karatas, Ertugrul; Ozsu, Damla; Ersoy, Ibrahim

    2014-01-01

    Objectives: The aim of this study was to compare the canal debridement capabilities of three single file systems, ProTaper, and K-files in oval-shaped canals. Materials and Methods: Seventy-five extracted human mandibular central incisors with oval-shaped root canals were selected. A radiopaque contrast medium (Metapex; Meta Biomed Co. Ltd., Chungcheongbuk-do, Korea) was introduced into the canal systems and the self-adjusting file (SAF), WaveOne, Reciproc, ProTaper, and K-files were used for the instrumentation of the canals. The percentage of removed contrast medium was calculated using pre- and post-operative radiographs. Results: An overall comparison between the groups revealed that the hand file (HF) and SAF groups presented the lowest percentage of removed contrast medium, whereas the WaveOne group showed the highest percentage (P < 0.001). The ProTaper group removed more contrast medium than the SAF and HF groups (P < 0.05). Conclusions: None of the instruments was able to remove the contrast medium completely. WaveOne performed significantly better than other groups. PMID:25202211

  20. Experimental Measurement of the Static Coefficient of Friction at the Ti-Ti Taper Connection in Total Hip Arthroplasty.

    Science.gov (United States)

    Bitter, T; Khan, I; Marriott, T; Schreurs, B W; Verdonschot, N; Janssen, D

    2016-03-01

    The modular taper junction in total hip replacements has been implicated as a possible source of wear. The finite-element (FE) method can be used to study the wear potential at the taper junction. For such simulations it is important to implement representative contact parameters, in order to achieve accurate results. One of the main parameters in FE simulations is the coefficient of friction. However, in current literature, there is quite a wide spread in coefficient of friction values (0.15 - 0.8), which has a significant effect on the outcome of the FE simulations. Therefore, to obtain more accurate results, one should use a coefficient of friction that is determined for the specific material couple being analyzed. In this study, the static coefficient of friction was determined for two types of titanium-on-titanium stem-adaptor couples, using actual cut-outs of the final implants, to ensure that the coefficient of friction was determined consistently for the actual implant material and surface finish characteristics. Two types of tapers were examined, Biomet type-1 and 12/14, where type-1 has a polished surface finish and the 12/14 is a microgrooved system. We found static coefficients of friction of 0.19 and 0.29 for the 12/14 and type-1 stem-adaptor couples, respectively.

  1. The Effect of Crown-to-Implant Ratio on the Clinical Performance of Extra-Short Locking-Taper Implants.

    Science.gov (United States)

    Mangano, Francesco; Frezzato, Irene; Frezzato, Alberto; Veronesi, Giovanni; Mortellaro, Carmen; Mangano, Carlo

    2016-05-01

    The aim of the present prospective 5-year study was to evaluate the influence of crown-to-implant ratio (C/I ratio) on the survival, peri-implant marginal bone loss, and complications of extra-short (6.5 mm) locking-taper implants placed in the posterior areas of the jaw. Over a 2-year period, all patients presenting with partial edentulism associated with vertical defects of the posterior alveolar ridges and sufficient bone volume to place extra-short (6.5 mm length × 5 mm diameter) implants were considered for inclusion in this study. Fifty-one patients (22 men, 29 women; aged between 40 and 75 years) were included in this study. Sixty-eight extra-short, locking-taper implants were placed to support 49 single crowns and 9 fixed partial dentures. The C/I ratio was implants and ≥2 for 17 implants. All patients underwent the 5-year clinical examination. Two implants failed. Failure proportion was 2% in the C/Ishort, locking-taper implants may be successfully used in the posterior areas of the jaw.

  2. Measurement and optimization of the light collection uniformity in strongly tapered PWO crystals of the PANDA detector

    Science.gov (United States)

    Diehl, Stefan; Bremer, Daniel; Brinkmann, Kai-Thomas; Dormenev, Valery; Eissner, Tobias; Novotny, Rainer W.; Rosenbaum, Christoph; Zaunick, Hans-Georg; PANDA Collaboration

    2017-06-01

    The uniformity of the light collection is a crucial parameter for detectors based on inorganic scintillation crystals to guarantee a response proportional to the deposited energy. Especially in case of tapered crystals, like they are widely used to realize a 4π geometry of electromagnetic calorimeters (EMC) in high energy physics experiments, a strong non-uniformity is introduced by an additional focusing of the scintillation light due to the tapered geometry. The paper will discuss the determination and the reduction of the non-uniformity in strongly tapered lead tungstate crystals as used for the construction of the electromagnetic calorimeter of the PANDA detector at the future Facility for Antiproton and Ion Research (FAIR). Among different concepts for an uniformization a single de-polished lateral side face provided the optimum result with a remaining non-uniformity below 5% in good agreement with similar studies for the CMS ECAL at LHC. The impact on the achievable energy resolution in the energy regime of photons below 800 MeV is discussed in detail in comparison to GEANT4 simulations. The comparison of the response of two arrays with polished and de-polished crystals, respectively, shows in the latter case a significant improvement of the constant term of the parametrization of the energy resolution down to 0.5% accompanied by only very slight increase of the statistical term.

  3. Measurement and optimization of the light collection uniformity in strongly tapered PWO crystals of the PANDA detector

    Energy Technology Data Exchange (ETDEWEB)

    Diehl, Stefan; Bremer, Daniel; Brinkmann, Kai-Thomas; Dormenev, Valery; Eissner, Tobias; Novotny, Rainer W.; Rosenbaum, Christoph; Zaunick, Hans-Georg

    2017-06-11

    The uniformity of the light collection is a crucial parameter for detectors based on inorganic scintillation crystals to guarantee a response proportional to the deposited energy. Especially in case of tapered crystals, like they are widely used to realize a 4π geometry of electromagnetic calorimeters (EMC) in high energy physics experiments, a strong non-uniformity is introduced by an additional focusing of the scintillation light due to the tapered geometry. The paper will discuss the determination and the reduction of the non-uniformity in strongly tapered lead tungstate crystals as used for the construction of the electromagnetic calorimeter of the PANDA detector at the future Facility for Antiproton and Ion Research (FAIR). Among different concepts for an uniformization a single de-polished lateral side face provided the optimum result with a remaining non-uniformity below 5% in good agreement with similar studies for the CMS ECAL at LHC. The impact on the achievable energy resolution in the energy regime of photons below 800 MeV is discussed in detail in comparison to GEANT4 simulations. The comparison of the response of two arrays with polished and de-polished crystals, respectively, shows in the latter case a significant improvement of the constant term of the parametrization of the energy resolution down to 0.5% accompanied by only very slight increase of the statistical term.

  4. Incident energy and charge deposition dependences of electron transmission through a microsized tapered glass capillary

    Energy Technology Data Exchange (ETDEWEB)

    Wickramarachchi, S.J. [Department of Physics, Western Michigan University, Kalamazoo, MI 49008 (United States); Ikeda, T. [RIKEN Nishina Center for Accelerator Based Science, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Dassanayake, B.S. [Department of Physics, Faculty of Science, University of Peradeniya (Sri Lanka); Keerthisinghe, D.; Tanis, J.A. [Department of Physics, Western Michigan University, Kalamazoo, MI 49008 (United States)

    2016-09-01

    An experimental study of electron transmission and guiding through a tapered glass capillary has been performed. Electrons were transmitted for tilt angles up to ∼6.5° and ∼9.5° (laboratory angles) for incident energies of 500 and 1000 eV, respectively. It is found that elastic and inelastic contributions give rise to distinguishable peaks in the transmitted profile. For 500 eV elastic transmission dominates the profile, while for 1000 eV both elastic and inelastic contributions are present. The transmission for both energies was studied as a function of the charge (time) deposition and found to be strongly dependent. Results suggest fundamental differences between 500 and 1000 eV incident electrons. For 500 eV the transmission slowly increases suggesting charge up of the capillary wall, reaching relative stability with infrequent breakdowns for all angles investigated. For 1000 eV for tilt angles near zero degrees the time dependent profile shows oscillations in the transmission, which never reached a stable condition, while for the larger angle investigated the transmission reached near equilibrium. Inelastic processes dominated the transmission for 1000 eV even at very small tilt angles, but was generally elastic (due to Coulomb deflection) for 500 eV even for the largest tilt angle measured.

  5. Assembly-Controlled Permeability of Layer-by-Layer Polymeric Microcapsules Using a Tapered Fluidized Bed.

    Science.gov (United States)

    Noi, Ka Fung; Roozmand, Ali; Björnmalm, Mattias; Richardson, Joseph J; Franks, George V; Caruso, Frank

    2015-12-23

    Nano- and microcapsules engineered through layer-by-layer (LbL) assembly are finding an increasingly large number of applications as catalysts, electrochemical biosensors, bioreactors, artificial cells and drug delivery vehicles. While centrifugation-based LbL assembly is the most common method for coating template particles and preparing capsules, it is a batch process and requires frequent intervention that renders the system challenging to automate and scale up. Here, we report the use of a tapered fluidized bed (TFB) for the preparation of multilayered polymer capsules. This is a significant improvement over our recent approach of fluidizing particles in cylindrical fluidized beds (CFB) for LbL assembly. We demonstrate that TFB is compatible with particles microcapsules demonstrate increased film thickness and roughness compared with those prepared using centrifugation-based LbL assembly. Furthermore, PMASH microcapsules exhibit lower swelling and permeability when prepared via TFB LbL assembly compared with centrifugation-based LbL assembly due to enhanced multilayer deposition, entanglement, and cross-linking. Therefore, polymeric capsules fabricated via TFB LbL assembly may be useful for encapsulation and retention of relatively low molecular weight (∼20 kDa) hydrophilic biomacromolecules to passively or responsively release the payload for drug delivery applications.

  6. Experimental analysis and prediction of antisymmetric wave motion in a tapered anisotropic waveguide.

    Science.gov (United States)

    Moll, Jochen; Wandowski, Tomasz; Malinowski, Pawel; Radzienski, Maciej; Opoka, Szymon; Ostachowicz, Wieslaw

    2015-07-01

    This paper presents experimental results for wave propagation in an anisotropic multilayered structure with linearly varying cross section. Knowing the dispersion and wave propagation properties in such a structure is of great importance for non-destructive material testing and structural health monitoring applications for accurate damage detection and localization. In the proposed study, the wavefield is generated by a circular piezoelectric wafer active sensor and measured by a scanning laser-Doppler-vibrometer. The measurements are compared with a theoretical group delay estimation and a signal prediction for the antisymmetric wave motion along the non-uniform propagation path. The required dispersion curves are derived from the well-known global matrix method for segments of constant thickness. A multidimensional frequency-wavenumber analysis of linescan data and the full wavefield provides further insight of the adiabatic wave motion because the wavenumber changes along the tapered geometry of the waveguide. In addition, it is demonstrated that a terahertz time-domain system can be used in glass-fiber reinforced plastic structures as a tool to estimate the thickness profile of thin structures by means of time-of-flight measurements. This information is particularly important for guided wave-based diagnostics of structures with unknown thickness.

  7. A Study of the Anechoic Performance of Rice Husk-Based, Geometrically Tapered, Hollow Absorbers

    Directory of Open Access Journals (Sweden)

    Muhammad Nadeem Iqbal

    2014-01-01

    Full Text Available Although solid, geometrically tapered microwave absorbers are preferred due to their better performance, they are bulky and must have a thickness on the order of λ or more. The goal of this study was to design lightweight absorbers that can reduce the electromagnetic reflections to less than −10 dB. We used a very simple approach; two waste materials, that is, rice husks and tire dust in powder form, were used to fabricate two independent samples. We measured and used their dielectric properties to determine and compare the propagation constants and quarter-wave thickness. The quarter-wave thickness for the tire dust was 3 mm less than that of the rice husk material, but we preferred the rice-husk material. This preference was based on the fact that our goal was to achieve minimum backward reflections, and the rice-husk material, with its low dielectric constant, high loss factor, large attenuation per unit length, and ease of fabrication, provided a better opportunity to achieve that goal. The performance of the absorbers was found to be better (lower than −20 dB, and comparison of the results proved that the hollow design with 58% less weight was a good alternative to the use of solid absorbers.

  8. Reconfigured and Notched Tapered Slot UWB Antenna for Cognitive Radio Applications

    Directory of Open Access Journals (Sweden)

    Tamer Aboufoul

    2012-01-01

    Full Text Available A compact reconfigurable and notched ultra-wideband (UWB tapered slot antenna (TSA is presented. The antenna reconfiguration operation principle relies on 2 mechanisms: in the first mechanism a resonator parasitic microstrip line electrically coupled to the TSA is used to notch the TSA at a specific frequency and the second mechanism relies on changing the input impedance matching of the antenna by means of changing the length of a stub line extended from an additional tiny partial ground on the back side of the antenna. The reflection coefficient, radiation patterns, and gain simulations and measurements for the proposed antenna are presented to verify the design concepts featuring a very satisfactory performance. Total efficiency simulations and measurements are also presented to highlight the filtering performance of the reconfigured antenna. When the antenna was reconfigured from the UWB to work into multiple frequency bands, the radiation patterns were still the same and the total peak gain has slightly improved compared to the UWB case. In addition, when the antenna operated in the notched mode, the gain has significantly dropped at the notch frequency. The simplicity and flexibility of the proposed multimode antenna make it a good candidate for future cognitive radio front ends.

  9. Compact Elliptically Tapered Slot Antenna with Non-uniform Corrugations for Ultra-wideband Applications

    Directory of Open Access Journals (Sweden)

    F. G. Zhu

    2013-04-01

    Full Text Available A small size elliptically tapered slot antenna (ETSA fed by coplanar waveguide (CPW for ultra-wideband (UWB applications is proposed. It is printed on an FR4 substrate and occupies a size of 37×34×0.8 mm^3. A pair of quarter circular shapes is etched on the radiator to reduce the size. To overcome the limitation of uniform corrugation, non-uniform corrugation is utilized to reduce the cross-polarization level. A parametric study is carried out to investigate the effects of circular cut and corrugations. In order to validate the design, a prototype is fabricated and measured. Both simulated and measured results confirm that the proposed antenna achieves a good performance of a reflection coefficient below -10 dB from 3.1 GHz to 10.6 GHz, including a maximum antenna gain of 8.1dBi, directional patterns in the end-fire direction, low cross-polarization level below -20 dB and linear phase response. The antenna is promising for applications in UWB impulse radar imaging.

  10. Films Consisting of Innumerable Tapered Nanopillars of Mesoporous Silica for Universal Antireflection Coatings.

    Science.gov (United States)

    Miyata, Hirokatsu; Kitamura, Shin; Watanabe, Masatoshi; Takahashi, Masahiko

    2016-05-20

    Films with a fine structure consisting of innumerable nanopillars of mesoporous silica (MPS) are formed by a reactive ion etching process with a fluorine-containing gas. Each nanopillar has a tapered shape with a uniform height, which effectively suppresses reflection by the formation of an ideal graded refractive index structure. The nanopillars are spontaneously formed under low-pressure conditions, wherein locally deposited Al-F compounds, originating from an alumina plate in the etching chamber, work as a fine etching mask. The high etching rate of the MPS film allows a very high aspect ratio of the nanopillars. The refractive index of the MPS nanopillars can be universally tuned by a controlled incorporation of TiO2 into the mesopores, which results in effective reduction of reflectance on a given substrate. The outstanding antireflection performance is experimentally demonstrated for glass substrates with a wide refractive index range. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. PENGEMBANGAN VARIATIF RANCANGAN ANTENA PANEL MICROSTRIP TAPERED PATCH DALAM SISTEM KOMUNIKASI WI-FI

    Directory of Open Access Journals (Sweden)

    Putu Artawan

    2013-04-01

    Full Text Available Pada penelitian ini dilakukan pengembangan rancangan antena microstrip tapered patch untuk dilakukan pengukuran parameternya sebagai karakteristik dari antena Microstrip. Penelitian ini sebagai pengembangan variatif rancangan untuk memperoleh hasil yang lebih optimal. Metode eksperiment dilakukan dalam penelitian ini. Tahap pengerjaanya yaitu membuat desain rancangan antena sesuai persamaan yang ada yang kemudian dirancang dengan metode UV Photoresist laminate. Hasil rancangan antena diukur untuk mendapatkan karakteristik sebagai parameter antena meliputi frekuensi (bandwidth, SWR, VSWR, koofesien refleksi, pola radiasi dan penguatan (gain serta nilai HPBW. Nilai-nilai tersebut mencerminkan karakter dari sebuah antena sebagai parameter antena yang layak diimplementasikan dalam sistem komunikasi internet dengan sistem wi-fi. Hasil penelitian ini meliputi: nilai lebar pita (bandwidth = 0.21 GHz, VSWR = 1,23, SWR = 1,79,  return loss = -20,00 dB, koofesien refleksi = 0,10 dan grafik pola radiasi dengan penguatan (gain = 17 dB (polarisasi vertikal, 20 dB (polarisasi horizontal. Nilai Half Power Beamwidth (HPBW 820 untuk pola radiasi vertikal dan pola radiasi horizontal. Kesalahan (error hasil pengukuran 0,12% dengan keseksamaan 99,88%. Hasil ini memberikan indikasi sebagai rancangan antena yang layak untuk sistem komunikasi wi-fi. Penelitian ini sebagai salah satu aplikasi ilmu Fisika dalam dunia teknologi informasi dan diharapkan dapat bermanfaat sebagai dinamika wahana salah satu produk penerapan ilmu Fisika dalam bidang Teknologi Informasi.

  12. Arrays of Segmented, Tapered Light Guides for Use with Large, Planar Scintillation Detectors.

    Science.gov (United States)

    Raylman, Raymond R; Vaigneur, Keith; Stolin, Alexander V; Jaliparthi, Gangadhar

    2015-06-01

    Metabolic imaging techniques can potentially improve detection and diagnosis of cancer in women with radiodense and/or fibrocystic breasts. Our group has previously developed a high-resolution positron emission tomography imaging and biopsy device (PEM-PET) to detect and guide the biopsy of suspicious breast lesions. Initial testing revealed that the imaging field-of-view (FOV) of the scanner was smaller than the physical size of the detector's active area, which could hinder sampling of breast areas close to the chest wall. The purpose of this work was to utilize segmented, tapered light guides for optically coupling the scintillator arrays to arrays of position-sensitive photomultipliers to increase both the active FOV and identification of individual scintillator elements. Testing of the new system revealed that the optics of these structures made it possible to discern detector elements from the complete active area of the detector face. In the previous system the top and bottom rows and left and right columns were not identifiable. Additionally, use of the new light guides increased the contrast of individual detector elements by up to 129%. Improved element identification led to a spatial resolution increase by approximately 12%. Due to attenuation of light in the light guides the detector energy resolution decreased from 18.5% to 19.1%. Overall, these improvements should increase the field-of-view and spatial resolution of the dedicated breast-PET system.

  13. Non-Uniform Laser Surface Texturing of an Un-Tapered Square Pad for Tribological Applications

    Directory of Open Access Journals (Sweden)

    Antonio Ancona

    2017-10-01

    Full Text Available Femtosecond laser surface micro-texturing has emerged as a promising technology to enhance the tribological properties of different kinds of electromechanical devices. In this research paper, we have exploited the intrinsic flexibility and micrometric accuracy of femtosecond laser ablation to realize complex micro-structural modifications on the surface of a laboratory prototype of a steel thrust bearing (un-tapered pad. The Bruggeman Texture Hydrodynamics theory (BTH is employed for the design of the anisotropic and non-uniform texture maximizing the thrust load of the pad prototype. The preliminary experimental results, reported in this work, show that the non-uniform micro-texture largely affects the friction characteristics of the contact. In particular, in agreement with the BTH predictions, the tribo-system shows friction properties that are strongly sensitive to the direction of the sliding speed, as a consequence of the micro-fluid dynamics which are designed to occur only in a specific sliding direction. We suggest that the joint action of virtual prototyping (BTH lubrication theory and ultrafast laser micro-prototyping can lead to unconventional and impressive results in terms of enhanced or tailored contact mechanics properties of the generic lubricated tribopair.

  14. Taper segmented equation generated from the equation which describes geometric solids

    Directory of Open Access Journals (Sweden)

    Valdir Carlos Lima de Andrade

    2014-12-01

    Full Text Available In this work, from the equation y=bxr, a methodology that links the different geometric solids in four segments of standing trees trunks was developed. Data from 1297 scaled trees of the hybrid Eucalyptus grandis and Eucalyptus urophylla were used for the preliminary analysis and independent data from another 65 scaled trees for the validation of the developed methodology related to the taper and volume predictions. The evaluation criteria of the quality and fitness of the methodology were based on the graphic analyses of the residuals and on the followings statistics: mean percentual deviation, residual standard error, accuracy obtained from the Chi-square test and the variance analyses by the Entirely Randomized Design in Subdivided Blocs with the use of the Dunnett test, both at 0.05 significance level. It was concluded that from a greometric solid, or optimized dendrometric prototype, it is possible to simulated the scaling of standing trees, measuring the trunk diameters located only at: 0.3 m, 1.3 m, h-2/2 and on h-1,25/1,25, besides the total height h, whose processes were included in a methodology named Relative Height Method with Two Diameters (hr2D.

  15. Stress on external hexagon and Morse taper implants submitted to immediate loading.

    Science.gov (United States)

    Odo, Caroline H; Pimentel, Marcele J; Consani, Rafael L X; Mesquita, Marcelo F; Nóbilo, Mauro A A

    2015-01-01

    This study aimed to evaluate the stress distribution around external hexagon (EH) and Morse taper (MT) implants with different prosthetic systems of immediate loading (distal bar (DB), casting technique (CT), and laser welding (LW)) by using photoelastic method. Three infrastructures were manufactured on a model simulating an edentulous lower jaw. All models were composed by five implants (4.1 mm × 13.0 mm) simulating a conventional lower protocol. The samples were divided into six groups. G1: EH implants with DB and acrylic resin; G2: EH implants with titanium infrastructure CT; G3: EH implants with titanium infrastructure attached using LW; G4: MT implants with DB and acrylic resin; G5: MT implants with titanium infrastructure CT; G6: MT implants with titanium infrastructure attached using LW. After the infrastructures construction, the photoelastic models were manufactured and a loading of 4.9 N was applied in the cantilever. Five pre-determined points were analyzed by Fringes software. Data showed significant differences between the connection types (p immediate loading not influenced stress concentration.

  16. Opioid withdrawal presenting only nausea during tapering of oxycodone after celiac plexus block: a case report.

    Science.gov (United States)

    Sakamoto, Akiyuki; Takayama, Hiroto; Mamiya, Keiko; Koizumi, Tomonobu

    2016-01-01

    Celiac plexus block (CPB) is an effective treatment for patients suffering pain. CPB may allow for a reduction in opioid dosage, and may alleviate some of the unwanted side effects of these drugs. However, there is a substantial risk of withdrawal symptoms after reduction of opioid dose. We describe a case of pancreatic cancer developing opioid withdrawal after CPB, who presented only nausea. A 70-year-old man was referred to our hospital due to severe pancreatic cancer pain. He was administered oxycodone (oxycontin®) at 240 mg per day, and presented nausea and anorexia as side effects. CPB was performed due to insufficient pain relief. His pain disappeared on the same day as treatment. Oxycodone was reduced to 160 mg/day, and further reduced two days later to 80 mg/day. However, he complained of more severe nausea and loss of appetite even after tapering of oxycodone. Physical examination, blood chemistry examination, and brain computed tomography (CT) showed no abnormalities. Administration of fast-release oxycodone (Oxinome®) at a dose of 10 mg immediately improved his nausea. There have been no previous reports of nausea as the sole symptom of opioid withdrawal. The present case indicates that unless opioid side effects improve after dosage reduction, the possibility that they may be withdrawal symptoms should also be considered.

  17. Analysis of resistance to fatigue between straight solid and anatomic abutments of Morse taper system

    Directory of Open Access Journals (Sweden)

    Vanessa Tavares de GOIS-SANTOS

    Full Text Available Abstract Background The study of the phenomenon of fatigue is essential because implant failures usually are caused by this process. Purpose The objective of this study was to examine the fatigue resistance of straight and anatomical abutments joints that were submitted to cyclic loads. Material and method We used 37 Morse taper implants and 37 abutments, divided into two groups (n= 16: straight abutment, n= 21 anatomical abutment. The sets were submitted to cyclic loading (5 million using servo-hydraulic equipment. Three sets from each group were subjected to bending tests to determine the maximum load resistance, which served as the parameter for comparison of the cyclic tests. We evaluated number of cycles, load and bending moment. Result Of the 31 abutments cyclically tested, 17 (54.8% fractured in fewer than 5 million cycles; 8 (25.8% of these were straight abutments, and 9 (29% were anatomical. A total of 14 samples (45.2% resisted the cyclic loading. According to Fisher's exact test, there was no difference between groups as the fracture. Conclusion Despite of the straight abutments have higher average load and bending moment on the anatomical, both types of abutments showed similar performance as the fracture strength in vitro.

  18. Evaluation of factors that allow the clinician to taper inhaled corticosteroids in childhood asthma

    Directory of Open Access Journals (Sweden)

    Kentaro Matsuda

    1999-01-01

    Full Text Available Inhaled corticosteroids are potent and effective treatment agents for controlling symptoms of childhood asthma. However, there are no predictive factors that help to determine which patients with asthma are likely to be tapered off inhaled corticosteroids successfully. We examined whether any factor or combination of factors could help the clinician safely discontinue inhaled steroid therapy. Thirty-six asthmatic children whose symptoms were stable on low-dose beclomethasone dipropionate (BDP were divided by parental choice into two groups: maintenance BDP (n = 11 and no BDP (n = 25. Methacholine inhalation tests were performed at the beginning of the study and after 1 month. Twelve children (48% who had BDP discontinued developed exacerbations after 2–3 months, whereas there were no problems in the maintenance group. The no BDP group was retrospectively divided into two subgroups: exacerbation (+ and (−. The threshold to methacholine in the exacerbation (+ subgroup decreased significantly in advance of clinical symptoms. The two subgroups were analyzed statistically by two-group discriminant function analysis. The change in threshold to methacholine, the dose and potency of drugs, duration of asthma and gender (female correlated with exacerbation. These results suggest that discontinuation of inhaled steroids should be done carefully, even in stable asthmatic children. The methacholine inhalation test, gender, drugs and history may be used as references for discontinuing inhaled steroids.

  19. Influences of internal tapered abutment designs on bone stresses around a dental implant: three-dimensional finite element method with statistical evaluation.

    Science.gov (United States)

    Chu, Chun-Ming; Huang, Heng-Li; Hsu, Jui-Ting; Fuh, Lih-Jyh

    2012-01-01

    The aim of this study is to determine the effects of various designs of internal tapered abutment joints on the stress induced in peri-implant crestal bone by using the three-dimensional finite element method and statistical analyses. Thirty-six models with various internal tapered abutment-implant interface designs including different abutment diameters (3.0, 3.5, and 4.0 mm), connection depths (4, 6, and 8 mm), and tapers (2°, 4°, 6°, and 8°) were constructed. A force of 170 N was applied to the top surface of the abutment either vertically or 45° obliquely. The maximum von Mises bone-stress values in the crestal bone surrounding the implant were statistically analyzed using analysis of variance. In addition, patterns of bone stress around the implant were examined. The results demonstrate that a smaller abutment diameter and a longer abutment connection significantly reduced the bone stresses (P implant interfaced connection was more parallel, bone stresses under vertical loading were less (P = 0.0002), whereas the abutment taper did not show significant effects on bone stresses under oblique loading (P = 0.83). Bone stresses were mainly influenced by the abutment diameter, followed by the abutment connection depth and the abutment taper. For an internal tapered abutment design, it was suggested that a narrower and deeper abutment-implant interface produced the biomechanical advantage of reducing the stress concentration in the crestal region around an implant.

  20. Mechanical and thermo-mechanical analyses of the tapered plug for plugging of deposition tunnels. A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Faelth, Billy (Clay Technology AB, Lund (Sweden)); Gatter, Patrik (Vattenfall Power Consultant AB, Stockholm (Sweden))

    2009-09-15

    This report presents results from a study that was carried out in order to examine the applicability of the tapered plug concept for plugging of deposition tunnels in the deep repository for spent nuclear fuel. The report presents results from mechanical and thermo-mechanical models of the tapered plug. The models were analyzed with 3DEC. The models included a portion of a deposition tunnel and its intersection with a main tunnel. In the deposition tunnel, a tapered concrete plug was installed. The plug was subjected to the combined load from the swelling backfill material and from pore pressure inside the deposition tunnel. The thermo-mechanical effects due to the heat generation in the spent fuel were also included in the analyses. Generic material parameter values for the concrete were used. The following items were studied: - Stresses and displacements in the plug. - Shear stresses and shear displacements in the rock-concrete interface. - Stress additions in the rock due to the loads. The sensitivity of the results to changes of constitutive models, to changes of the plug geometry and to pore water pressure in the rock-concrete interface was examined. The results indicate that the displacements in the plug will be within reasonable ranges but the stresses may locally be high enough that they exceed acceptable levels. However, they can be reduced by choice of advantageous plug geometry and by having a good rock-concrete bond. The results also show that the stress additions in the rock due to the thermal load may yield stresses that locally exceed the spalling strength of the rock. At most locations, however, the rock stresses will amount at lower levels. It was concluded that, with choice of an appropriate design, the tapered plug seems to be an applicable concept for plugging of deposition tunnels. It was also concluded that further studies of the tapered plug concept should use material properties parameter values for low-pH concrete. Further, they should also

  1. Fast 3D multiple fan-beam CT systems

    Science.gov (United States)

    Kohlbrenner, Adrian; Haemmerle, Stefan; Laib, Andres; Koller, Bruno; Ruegsegger, Peter

    1999-09-01

    Two fast, CCD-based three-dimensional CT scanners for in vivo applications have been developed. One is designed for small laboratory animals and has a voxel size of 20 micrometer, while the other, having a voxel size of 80 micrometer, is used for human examinations. Both instruments make use of a novel multiple fan-beam technique: radiation from a line-focus X-ray tube is divided into a stack of fan-beams by a 28 micrometer pitch foil collimator. The resulting wedge-shaped X-ray field is the key to the instrument's high scanning speed and allows to position the sample close to the X-ray source, which makes it possible to build compact CT systems. In contrast to cone- beam scanners, the multiple fan-beam scanner relies on standard fan-beam algorithms, thereby eliminating inaccuracies in the reconstruction process. The projections from one single rotation are acquired within 2 min and are subsequently reconstructed into a 1024 X 1024 X 255 voxel array. Hence a single rotation about the sample delivers a 3D image containing a quarter of a billion voxels. Such volumetric images are 6.6 mm in height and can be stacked on top of each other. An area CCD sensor bonded to a fiber-optic light guide acts as a detector. Since no image intensifier, conventional optics or tapers are used throughout the system, the image is virtually distortion free. The scanner's high scanning speed and high resolution at moderately low radiation dose are the basis for reliable time serial measurements and analyses.

  2. Strong-strong beam-beam simulation on parallel computer

    Energy Technology Data Exchange (ETDEWEB)

    Qiang, Ji

    2004-08-02

    The beam-beam interaction puts a strong limit on the luminosity of the high energy storage ring colliders. At the interaction points, the electromagnetic fields generated by one beam focus or defocus the opposite beam. This can cause beam blowup and a reduction of luminosity. An accurate simulation of the beam-beam interaction is needed to help optimize the luminosity in high energy colliders.

  3. Strong-strong beam-beam simulation on parallel computer

    International Nuclear Information System (INIS)

    Qiang, Ji

    2004-01-01

    The beam-beam interaction puts a strong limit on the luminosity of the high energy storage ring colliders. At the interaction points, the electromagnetic fields generated by one beam focus or defocus the opposite beam. This can cause beam blowup and a reduction of luminosity. An accurate simulation of the beam-beam interaction is needed to help optimize the luminosity in high energy colliders

  4. Outcome of a modular tapered uncemented titanium femoral stem in revision hip arthroplasty.

    Science.gov (United States)

    Hoberg, Maik; Konrads, Christian; Engelien, Jana; Oschmann, Dorothee; Holder, Michael; Walcher, Matthias; Rudert, Maximilian

    2015-09-01

    Revision hip arthroplasty using a modular tapered design gives the possibility for customising the prostheses to the individual anatomy intra-operatively. The success of this kind of surgery is still controversial due to the relative lack of medium- to long-term follow-up. Therefore we analysed the clinical and radiological outcome of the modular MRP-TITAN stem with diaphyseal fixation in revision hip surgery. In this retrospective study we included 136 consecutive patients with MRP-TITAN stem implanted during revision hip arthroplasty. The average follow-up was 55 months. For clinical evaluation we used the Harris Hip Score and the Merle d'Aubigné and Postel score. The health-related quality of life was determined with the visual analogue pain scale. The surgeries were performed 109 months after primary total hip arthroplasty on average. The main indications for the MRP-TITAN revision stem were aseptic loosening, infection, and periprosthetic fracture. In the clinical outcome, patients achieved 75.1 points in the Harris Hip Score and 14.4 points in the Merle d'Aubigné and Postel Score. Mean level of persisting pain was 0.7 (VAS). The overall survival of the MRP stem in revision hip arthroplasty revealed 85.6% survival at 9.75 years' follow-up with a repeat revision rate of 6.8%. Performing revision hip arthroplasty using the MRP-TITAN stem revealed a good clinical outcome. There is a tendency for better results in comparison with the information given in literature for cementless modular revision stems including a lower rate in re-revisions.

  5. A novel approach for space-temporal analysis of tapered slot antennas

    Directory of Open Access Journals (Sweden)

    A. R. Vilenskii

    2014-01-01

    Full Text Available This paper is dedicated to space-temporal radiation analysis of ultra-wideband (UWB tapered slot antennas (TSA. This antenna type has gained its popularity owing to remarkable UWB performance, low-profile geometry, and essential integration with active RF modules on a common substrate. When TSA is considered as a radiator of UWB pulses, the traditional radiation patterns are no longer fully satisfactory for estimation of its radiation performance. Thus, an antenna should be described as a linear circuit with its pulse response or complex transfer function.Currently, a very few papers reveal such performance features of TSA. Moreover, usually, an antenna model is based on the full-wave CAD model (FDTD, FIT and, thus, its straightforward evaluation is quite time consuming. However in previous works it was shown that radiation patterns of TSA could be calculated using an approximate two-step approach. Crucial ideas of this method are based on two core stages:aperture field distribution evaluation;radiation performance evaluation using a model of an elementary magnetic radiator in the neighborhood with semi-infinite conducting plane.The first step concerns the full-wave solution of two-dimensional problem on the eigenmode of a slot-line. Thus, unlike a three-dimensional full-wave CAD model, the two-step model enables to evaluate antenna performance in considerably shorter time retaining a high accuracy of results.A mathematical model of the improved two-step approach is comprehensively described in this paper, with special attention being paid to aperture field distribution. A developed calculation algorithm was successfully verified on benchmark models. Calculated results are compared with those of obtained via full-wave simulation. In all cases both methods have shown results of high identity.

  6. Short-Term Training Cessation as a Method of Tapering to Improve Maximal Strength.

    Science.gov (United States)

    Pritchard, Hayden J; Barnes, Matthew J; Stewart, Robin J C; Keogh, Justin W L; McGuigan, Michael R

    2018-02-01

    Pritchard, HJ, Barnes, MJ, Stewart, RJC, Keogh, JWL, and McGuigan, MR. Short-term training cessation as a method of tapering to improve maximal strength. J Strength Cond Res 32(2): 458-465, 2018-The aim of this study was to determine the effects of 2 different durations of training cessation on upper- and lower-body maximal strength performance and to investigate the mechanisms underlying performance changes following short-term training cessation. Eight resistance trained males (23.8 ± 5.4 years, 79.6 ± 10.2 kg, 1.80 ± 0.06 m, relative deadlift 1 repetition maximum of 1.90 ± 0.30 times bodyweight [BW]) each completed two 4-week strength training periods followed by either 3.5 days (3.68 ± 0.12 days) or 5.5 days (5.71 ± 0.13 days) of training cessation. Testing occurred pretraining (T1), on the final day of training (T2), and after each respective period of training cessation (T3). Participants were tested for salivary testosterone and cortisol, plasma creatine kinase, psychological profiles, and performance tests (countermovement jump [CMJ], isometric midthigh pull, and isometric bench press [IBP]) on a force plate. Participants' BW increased significantly over time (p = 0.022). The CMJ height and IBP peak force showed significant increases over time (p = 0.013, 0.048, and 0.004, respectively). Post hoc testing showed a significant increase between T1 and T3 for both CMJ height and IBP peak force (p = 0.022 and 0.008 with effect sizes of 0.30 and 0.21, respectively). No other significant differences were seen for any other measures. These results suggest that a short period of strength training cessation can have positive effects on maximal strength expression, perhaps because of decreases in neuromuscular fatigue.

  7. Performance of conical abutment (Morse Taper) connection implants: a systematic review.

    Science.gov (United States)

    Schmitt, Christian M; Nogueira-Filho, Getulio; Tenenbaum, Howard C; Lai, Jim Yuan; Brito, Carlos; Döring, Hendrik; Nonhoff, Jörg

    2014-02-01

    In this systematic review, we aimed to compare conical versus nonconical implant-abutment connection systems in terms of their in vitro and in vivo performances. An electronic search was performed using PubMed, Embase, and Medline databases with the logical operators: "dental implant" AND "dental abutment" AND ("conical" OR "taper" OR "cone"). Names of the most common conical implant-abutment connection systems were used as additional key words to detect further data. The search was limited to articles published up to November 2012. Recent publications were also searched manually in order to find any relevant studies that might have been missed using the search criteria noted above. Fifty-two studies met the inclusion criteria and were included in this systematic review. As the data and methods, as well as types of implants used was so heterogeneous, this mitigated against the performance of meta-analysis. In vitro studies indicated that conical and nonconical abutments showed sufficient resistance to maximal bending forces and fatigue loading. However, conical abutments showed superiority in terms of seal performance, microgap formation, torque maintenance, and abutment stability. In vivo studies (human and animal) indicated that conical and nonconical systems are comparable in terms of implant success and survival rates with less marginal bone loss around conical connection implants in most cases. This review indicates that implant systems using a conical implant-abutment connection, provides better results in terms of abutment fit, stability, and seal performance. These design features could lead to improvements over time versus nonconical connection systems. © 2013 Wiley Periodicals, Inc.

  8. Hyperbolic-cosine waveguide tapers and oversize rectangular waveguide for reduced broadband insertion loss in W-band electron paramagnetic resonance spectroscopy

    Science.gov (United States)

    Mett, R. R.; Sidabras, J. W.; Anderson, J. R.; Hyde, J. S.

    2011-01-01

    The two-way insertion loss of a 1 m length of waveguide was reduced by nearly 5 dB over a 4% bandwidth at W-band (94 GHz) for an electron paramagnetic resonance (EPR) spectrometer relative to WR10 waveguide. The waveguide has an oversize section of commercially available rectangular WR28 and a novel pair of tapers that vary in cross section with axial position according to a hyperbolic-cosine (HC) function. The tapers connect conventional rectangular WR10 waveguide to the WR28. For minimum loss, the main mode electric field is parallel to the long side of the WR28. Using mode coupling theory, the position of maximum flare (inflection point) in the taper was optimized with respect to the coupling to higher order modes and the reflection of the main mode. The optimum inflection point position is about one-tenth of the taper length from the small end of the taper. Reflection and coupling were reduced by about 20 dB relative to a pyramidal (linear) taper of the same length. Comb-like dips in the transmission coefficient produced by resonances of the higher order modes in the oversize section were about 0.03 dB. Specially designed high-precision, adjustable WR28 flanges with alignment to about 5 μm were required to keep higher order mode amplitudes arising from the flanges comparable to those from the HC tapers. Minimum return loss was about 30 dB. This paper provides a foundation for further optimization, if needed. Methods are not specific to EPR or the microwave frequency band. PMID:21806211

  9. The impact of hospital-wide use of a tapered-cuff endotracheal tube on the incidence of ventilator-associated pneumonia.

    Science.gov (United States)

    Bowton, David L; Hite, R Duncan; Martin, R Shayn; Sherertz, Robert

    2013-10-01

    Aspiration of colonized oropharyngeal secretions is a major factor in the pathogenesis of ventilator-associated pneumonia (VAP). A tapered-cuff endotracheal tube (ETT) has been demonstrated to reduce aspiration around the cuff. Whether these properties are efficacious in reducing VAP is not known. This 2-period, investigator-initiated observational study was designed to assess the efficacy of a tapered-cuff ETT to reduce the VAP rate. All intubated, mechanically ventilated patients over the age of 18 were included. During the baseline period a standard, barrel-shaped-cuff ETT (Mallinckrodt Hi-Lo) was used. All ETTs throughout the hospital were then replaced with a tapered-cuff ETT (TaperGuard). The primary outcome variable was the incidence of VAP per 1,000 ventilator days. We included 2,849 subjects, encompassing 15,250 ventilator days. The mean ± SD monthly VAP rate was 3.29 ± 1.79/1,000 ventilator days in the standard-cuff group and 2.77 ± 2.00/1,000 ventilator days in the tapered-cuff group (P = .65). While adherence to the VAP prevention bundle was high throughout the study, bundle adherence was significantly higher during the standard-cuff period (96.5 ± 2.7%) than in the tapered-cuff period (90.3 ± 3.5%, P = .01). In the setting of a VAP rate very near the average of ICUs in the United States, and where there was high adherence to a VAP prevention bundle, the use of a tapered-cuff ETT was not associated with a reduction in the VAP rate.

  10. Laser beam shaping techniques

    Energy Technology Data Exchange (ETDEWEB)

    DICKEY,FRED M.; WEICHMAN,LOUIS S.; SHAGAM,RICHARD N.

    2000-03-16

    Industrial, military, medical, and research and development applications of lasers frequently require a beam with a specified irradiance distribution in some plane. A common requirement is a laser profile that is uniform over some cross-section. Such applications include laser/material processing, laser material interaction studies, fiber injection systems, optical data image processing, lithography, medical applications, and military applications. Laser beam shaping techniques can be divided into three areas: apertured beams, field mappers, and multi-aperture beam integrators. An uncertainty relation exists for laser beam shaping that puts constraints on system design. In this paper the authors review the basics of laser beam shaping and present applications and limitations of various techniques.

  11. Beam induced RF heating

    CERN Document Server

    Salvant, B; Arduini, G; Assmann, R; Baglin, V; Barnes, M J; Bartmann, W; Baudrenghien, P; Berrig, O; Bracco, C; Bravin, E; Bregliozzi, G; Bruce, R; Bertarelli, A; Carra, F; Cattenoz, G; Caspers, F; Claudet, S; Day, H; Garlasche, M; Gentini, L; Goddard, B; Grudiev, A; Henrist, B; Jones, R; Kononenko, O; Lanza, G; Lari, L; Mastoridis, T; Mertens, V; Métral, E; Mounet, N; Muller, J E; Nosych, A A; Nougaret, J L; Persichelli, S; Piguiet, A M; Redaelli, S; Roncarolo, F; Rumolo, G; Salvachua, B; Sapinski, M; Schmidt, R; Shaposhnikova, E; Tavian, L; Timmins, M; Uythoven, J; Vidal, A; Wenninger, J; Wollmann, D; Zerlauth, M

    2012-01-01

    After the 2011 run, actions were put in place during the 2011/2012 winter stop to limit beam induced radio frequency (RF) heating of LHC components. However, some components could not be changed during this short stop and continued to represent a limitation throughout 2012. In addition, the stored beam intensity increased in 2012 and the temperature of certain components became critical. In this contribution, the beam induced heating limitations for 2012 and the expected beam induced heating limitations for the restart after the Long Shutdown 1 (LS1) will be compiled. The expected consequences of running with 25 ns or 50 ns bunch spacing will be detailed, as well as the consequences of running with shorter bunch length. Finally, actions on hardware or beam parameters to monitor and mitigate the impact of beam induced heating to LHC operation after LS1 will be discussed.

  12. Craft Stick Beams

    Science.gov (United States)

    Karplus, Alan K.

    1996-01-01

    The objective of this exercise is to provide a phenomenological 'hands-on' experience that shows how geometry can affect the load carrying capacity of a material used in construction, how different materials have different failure characteristics, and how construction affects the performance of a composite material. This will be accomplished by building beams of a single material and composite beams of a mixture of materials (popsicle sticks, fiberboard sheets, and tongue depressors); testing these layered beams to determine how and where they fail; and based on the failure analysis, designing a layered beam that will fail in a predicted manner. The students will learn the effects of lamination, adhesion, and geometry in layered beam construction on beam strength and failure location.

  13. Generation of single-frequency tunable green light in a coupled ring tapered diode laser cavity

    DEFF Research Database (Denmark)

    Jensen, Ole Bjarlin; Petersen, Paul Michael

    2013-01-01

    in the broad wavelength range from 1049 nm to 1093 nm and the beam propagation factor is improved from M2 = 2.8 to below 1.1. The laser frequency is automatically locked to the cavity resonance frequency using optical feedback. Furthermore, we show that this adaptive external cavity approach leads to efficient...

  14. Mechanisms and control of beam halo formation in intense microwave sources and accelerators

    Science.gov (United States)

    Chen, C.; Pakter, R.

    2000-05-01

    Halo formation and control in space-charge-dominated electron and ion beams are investigated in parameter regimes relevant to the development of high-power microwave (HPM) sources and high-intensity electron and ion linear accelerators. In particular, a mechanism for electron beam halo formation is identified in high-power periodic permanent magnet (PPM) focusing klystron amplifiers. It is found in self-consistent simulations that large-amplitude current oscillations induce mismatched beam envelope oscillations and electron beam halo formation. Qualitative agreement is found between simulations and the 50 MW 11.4 GHz PPM focusing klystron experiment at Stanford Linear Accelerator Center (SLAC) (D. Sprehn, G. Caryotakis, E. Jongewaard, and R. M. Phillips, "Periodic permanent magnetic development for linear collider X-band klystrons," Proceedings of the XIXth International Linac Conference, Argonne National Laboratory Report ANL-98/28, 1998, p. 689). Moreover, a new class of cold-fluid corkscrewing elliptic beam equilibria is discovered for ultrahigh-brightness, space-charge dominated electron or ion beam propagation through a linear focusing channel consisting of uniform solenoidal magnetic focusing fields, periodic solenoidal magnetic focusing fields, and/or alternating-gradient quadrupole magnetic focusing fields in an arbitrary arrangement including field tapering. As an important application of such new cold-fluid corkscrewing elliptic beam equilibria, a technique is developed and demonstrated for controlling of halo formation and beam hollowing in a rms-matched ultrahigh-brightness ion beam as it is injected from an axisymmetric Pierce diode into an alternating-gradient magnetic quadrupole focusing channel.

  15. Beam Extraction and Transport

    CERN Document Server

    Kalvas, T.

    2013-12-16

    This chapter gives an introduction to low-energy beam transport systems, and discusses the typically used magnetostatic elements (solenoid, dipoles and quadrupoles) and electrostatic elements (einzel lens, dipoles and quadrupoles). The ion beam emittance, beam space-charge effects and the physics of ion source extraction are introduced. Typical computer codes for analysing and designing ion optical systems are mentioned, and the trajectory tracking method most often used for extraction simulations is described in more detail.

  16. Mechanical beam isolator

    International Nuclear Information System (INIS)

    Post, R.F.; Vann, C.S.

    1996-10-01

    Back-reflections from a target, lenses, etc. can gain energy passing backwards through a laser just like the main beam gains energy passing forwards. Unless something blocks these back-reflections early in their path, they can seriously damage the laser. A Mechanical Beam Isolator is a device that blocks back-reflections early, relatively inexpensively, and without introducing aberrations to the laser beam

  17. Cyclotron radiation beam control

    International Nuclear Information System (INIS)

    Dominke, P.

    1983-01-01

    This patent application describes an apparatus for attenuating a beam of particulate radiation comprising a series of modules, each module being constituted by a sphere having a passage, a cupola covering said sphere and a base supporting said sphere, and means for causing movement of the spheres for aligning said passages with an axis of a beam line and arranging said passages out of alignment so as to attenuate the beam. (author)

  18. Chilled beam application guidebook

    CERN Document Server

    Butler, David; Gräslund, Jonas; Hogeling, Jaap; Lund Kristiansen, Erik; Reinikanen, Mika; Svensson, Gunnar

    2007-01-01

    Chilled beam systems are primarily used for cooling and ventilation in spaces, which appreciate good indoor environmental quality and individual space control. Active chilled beams are connected to the ventilation ductwork, high temperature cold water, and when desired, low temperature hot water system. Primary air supply induces room air to be recirculated through the heat exchanger of the chilled beam. In order to cool or heat the room either cold or warm water is cycled through the heat exchanger.

  19. Who needs hyperon beams

    International Nuclear Information System (INIS)

    Lipkin, H.J.

    1976-01-01

    Hyperon beams can provide new interesting information about hadron structure and their strong, electromagnetic and weak interactions. The dependence of hadron interactions on strangeness and baryon number is not understood, and data from hyperon beams can provide new clues to paradoxes which arise in the interpretation of data from conventional beams. Examples of interesting data are total and differential cross sections, magnetic moments and values of Gsub(A)/Gsub(V) for weak semileptonic decays. (author)

  20. Evaluation of apical deviation in root canals instrumented with K3 and ProTaper systems Avaliação do desvio apical em canais instrumentados pelos sistemas K3 e ProTaper

    Directory of Open Access Journals (Sweden)

    Mariana Diniz Bisi dos Santos

    2006-12-01

    Full Text Available OBJECTIVES: this study evaluated the apical deviation of curved root canals instrumented with K3 and ProTaper systems. MATERIAL AND METHODS: twenty root canals of human maxillary and mandibular first molars were employed, which were divided into 2 groups: group A (10 teeth was instrumented with the K3 system, and group B (10 teeth with the ProTaper system. Evaluation of deviation was performed by double radiographic exposure. Radiographs were achieved before and after instrumentation, with 0.3-second, thus allowing superimposition of images. Three-dimensional computerized tomograph was performed in 3 specimens in each group, as an additional means to evaluate the apical deviation. RESULTS: were evaluated by the parametric test Student-Newman-Keuls at 5%, which did not reveal significance between groups concerning the apical deviation. The results of computerized tomograph images demonstrated that the larger deviation of the root canal occurred at the distolingual area for both systems. CONCLUSIONS: both techniques produced a mild apical deviation. Computerized microtomography was shown to be accurate for experimental endodontics studies.OBJETIVOS: avaliar o desvio apical de canais radiculares curvos instrumentados pelos sistemas K3 e ProTaper. MATERIAIS E MÉTODOS: foram utilizados 20 canais radiculares de primeiros molares superiores e inferiores humanos, os quais foram divididos em 2 grupos, o grupo A (10 dentes foi instrumentado pelo sistema K3 e o grupo B (10 dentes com o sistema ProTaper, a forma de avaliação do desvio foi a dupla exposição radiográfica. As tomadas radiográficas foram feitas antes e após a instrumentação, com um tempo de 0,3 segundos em cada exposição, ocorrendo assim, sobreposição das imagens. Em 3 espécimes, de cada grupo, foi realizada a tomografia computadorizada tridimensional, como forma adicional de avaliar o desvio apical . Os resultados obtidos foram avaliados pelo teste paramétrico Student