WorldWideScience

Sample records for leakage induced hearing

  1. Transitory endolymph leakage induced hearing loss and tinnitus: depolarization, biphasic shortening and loss of electromotility of outer hair cells

    Science.gov (United States)

    Zenner, H. P.; Reuter, G.; Zimmermann, U.; Gitter, A. H.; Fermin, C.; LePage, E. L.

    1994-01-01

    There are types of deafness and tinnitus in which ruptures or massive changes in the ionic permeability of the membranes lining the endolymphatic space [e.g., of the reticular lamina (RL)] are believed to allow potassium-rich endolymph to deluge the low [K+] perilymphatic fluid (e.g., in the small spaces of Nuel). This would result in a K+ intoxication of sensory and neural structures. Acute attacks of Meniere's disease have been suggested to be an important example for this event. The present study investigated the effects of transiently elevated [K+] due to the addition of artificial endolymph to the basolateral cell surface of outer hair cells (OHC) in replicating endolymph-induced K+ intoxication of the perilymph in the small spaces of Nuel. The influence of K+ intoxication of the basolateral OHC cell surface on the transduction was then examined. Intoxication resulted in an inhibition of the physiological repolarizing K+ efflux from hair cells. This induced unwanted depolarizations of the hair cells, interfering with mechanoelectrical transduction. A pathological longitudinal OHC shortening was also found, with subsequent compression of the organ of Corti possibly influencing the micromechanics of the mechanically active OHC. Both micromechanical and electrophysiological alterations are proposed to contribute to endolymph leakage induced attacks of deafness and possibly also to tinnitus. Moreover, repeated or long-lasting K+ intoxications of OHC resulted in a chronic and complete loss of OHC motility. This is suggested to be a pathophysiological basis in some patients with chronic hearing loss resulting from Meniere's syndrome.

  2. Noise-Induced Hearing Loss

    Science.gov (United States)

    ... Home » Health Info » Hearing, Ear Infections, and Deafness Noise-Induced Hearing Loss On this page: What is ... I find additional information about NIHL? What is noise-induced hearing loss? Every day, we experience sound ...

  3. Radiation induced leakage current and stress induced leakage current in ultra-thin gate oxides

    International Nuclear Information System (INIS)

    Ceschia, M.; Paccagnella, A.; Cester, A.; Scarpa, A.

    1998-01-01

    Low-field leakage current has been measured in thin oxides after exposure to ionizing radiation. This Radiation Induced Leakage Current (RILC) can be described as an inelastic tunneling process mediated by neutral traps in the oxide, with an energy loss of about 1 eV. The neutral trap distribution is influenced by the oxide field applied during irradiation, thus indicating that the precursors of the neutral defects are charged, likely being defects associated to trapped holes. The maximum leakage current is found under zero-field condition during irradiation, and it rapidly decreases as the field is enhanced, due to a displacement of the defect distribution across the oxide towards the cathodic interface. The RILC kinetics are linear with the cumulative dose, in contrast with the power law found on electrically stressed devices

  4. Macrophage migration inhibitory factor induces vascular leakage via autophagy

    Directory of Open Access Journals (Sweden)

    Hong-Ru Chen

    2015-01-01

    Full Text Available Vascular leakage is an important feature of acute inflammatory shock, which currently has no effective treatment. Macrophage migration inhibitory factor (MIF is a pro-inflammatory cytokine that can induce vascular leakage and plays an important role in the pathogenesis of shock. However, the mechanism of MIF-induced vascular leakage is still unclear. In this study, using recombinant MIF (rMIF, we demonstrated that MIF induced disorganization and degradation of junction proteins and increased the permeability of human endothelial cells in vitro. Western blotting analysis showed that rMIF treatment induced LC3 conversion and p62 degradation. Inhibition of autophagy with a PI3K inhibitor (3-MA, a ROS scavenger (NAC or autophagosomal-lysosomal fusion inhibitors (bafilomycin A1 and chloroquine rescued rMIF-induced vascular leakage, suggesting that autophagy mediates MIF-induced vascular leakage. The potential involvement of other signaling pathways was also studied using different inhibitors, and the results suggested that MIF-induced vascular leakage may occur through the ERK pathway. In conclusion, we showed that MIF triggered autophagic degradation of endothelial cells, resulting in vascular leakage. Inhibition of MIF-induced autophagy may provide therapeutic targets against vascular leakage in inflammatory shock.

  5. Hearing: Noise-Induced Hearing Loss

    Science.gov (United States)

    ... reduce your exposure to noise by choosing quiet leisure activities rather than noisy ones. Develop the habit ... the degree of your hearing loss, you may benefit from using a hearing aid (a device you ...

  6. Noise-induced hearing loss

    Directory of Open Access Journals (Sweden)

    Mariola Sliwinska-Kowalska

    2012-01-01

    Full Text Available Noise-induced hearing loss (NIHL still remains a problem in developed countries, despite reduced occupational noise exposure, strict standards for hearing protection and extensive public health awareness campaigns. Therefore NIHL continues to be the focus of noise research activities. This paper summarizes progress achieved recently in our knowledge of NIHL. It includes papers published between the years 2008-2011 (in English, which were identified by a literature search of accessible medical and other relevant databases. A substantial part of this research has been concerned with the risk of NIHL in the entertainment sector, particularly in professional, orchestral musicians. There are also constant concerns regarding noise exposure and hearing risk in "hard to control" occupations, such as farming and construction work. Although occupational noise has decreased since the early 1980s, the number of young people subject to social noise exposure has tripled. If the exposure limits from the Noise at Work Regulations are applied, discotheque music, rock concerts, as well as music from personal music players are associated with the risk of hearing loss in teenagers and young adults. Several recent research studies have increased the understanding of the pathomechanisms of acoustic trauma, the genetics of NIHL, as well as possible dietary and pharmacologic otoprotection in acoustic trauma. The results of these studies are very promising and offer grounds to expect that targeted therapies might help prevent the loss of sensory hair cells and protect the hearing of noise-exposed individuals. These studies emphasize the need to launch an improved noise exposure policy for hearing protection along with developing more efficient norms of NIHL risk assessment.

  7. [Hearing loss and idoneity--the segnalation of noise-induced hearing loss hearing Loss].

    Science.gov (United States)

    Albera, Roberto; Dagna, Federico; Cassandro, Claudia; Canale, Andrea

    2011-01-01

    Work idoneity in hearing loss must be related to working ability and evolution risks. Working ability is referred to the difficulties found in speech comprehension and in signals perception. As regards hearing loss evolution it is necessary to define if the subject is affected by conductive or neurosensorial hearing loss. In conductive hearing loss it is necessary to evaluate entity and frequential distribution of the deficit. In neurosensorial hearing loss it is necessary to distinguish between noise-induced hearing loss and extraprofessional hearing loss. In noise-induced hearing loss the evolution risk is high if the noise exposure is less than 10-15 years or the actual noise exposure is louder than the former. In case of extraprofessional hearing loss the evolution risk is higher in presbycusis, endolymphatic hydrops and toxic hearing loss. The necessity to report the presence on professionale noise-induced hearing loss arises if audiometric threshold is more than 25 dB at 0.5-1-2-3-4 kHz and if it is verified the professional origine of hearing loss.

  8. Treatment of Noise-Induced Hearing Loss

    National Research Council Canada - National Science Library

    d'Aldin, Gervais

    1999-01-01

    .... Guinea pigs are subjected to an acoustic trauma. The recovery of the noise-induced hearing loss is followed up to 14 days post exposure by electrocochleography and morphologic examination of the cochlea is performed...

  9. Review of leakage-flow-induced vibrations of reactor components

    International Nuclear Information System (INIS)

    Mulcahy, T.M.

    1983-05-01

    The primary-coolant flow paths of a reactor system are usually subject to close scrutiny in a design review to identify potential flow-induced vibration sources. However, secondary-flow paths through narrow gaps in component supports, which parallel the primary-flow path, occasionally are the excitation source for significant vibrations even though the secondary-flow rates are orders of magnitude smaller than the primary-flow rate. These so-called leakage flow problems are reviewed here to identify design features and excitation sources that should be avoided. Also, design rules of thumb are formulated that can be employed to guide a design, but quantitative prediction of component response is found to require scale-model testing

  10. Does erythropoietin augment noise induced hearing loss?

    DEFF Research Database (Denmark)

    Frederiksen, Birgitte Lidegaard; Cayé-Thomasen, Per; Lund, Søren Peter

    2007-01-01

    Noise-induced hearing loss may result from excessive release of glutamate, nitrogen oxide and reactive oxygen species. The effects of these factors on the inner ear may potentially be prevented or reduced by erythropoietin (EPO), as indicated by previously demonstrated neuro-protective effects of...

  11. Radiation-induced off-state leakage current in commercial power MOSFETs

    International Nuclear Information System (INIS)

    Dodd, Paul Emerson; Shaneyfelt, Marty Ray; Draper, Bruce Leroy; Felix, James Andrew; Schwank, James Ralph; Dalton, Scott Matthew

    2005-01-01

    The total dose hardness of several commercial power MOSFET technologies is examined. After exposure to 20 krad(SiO 2 ) most of the n- and p-channel devices examined in this work show substantial (2 to 6 orders of magnitude) increases in off-state leakage current. For the n-channel devices, the increase in radiation-induced leakage current follows standard behavior for moderately thick gate oxides, i.e., the increase in leakage current is dominated by large negative threshold voltage shifts, which cause the transistor to be partially on even when no bias is applied to the gate electrode. N-channel devices biased during irradiation show a significantly larger leakage current increase than grounded devices. The increase in leakage current for the p-channel devices, however, was unexpected. For the p-channel devices, it is shown using electrical characterization and simulation that the radiation-induced leakage current increase is related to an increase in the reverse bias leakage characteristics of the gated diode which is formed by the drain epitaxial layer and the body. This mechanism does not significantly contribute to radiation-induced leakage current in typical p-channel MOS transistors. The p-channel leakage current increase is nearly identical for both biased and grounded irradiations and therefore has serious implications for long duration missions since even devices which are usually powered off could show significant degradation and potentially fail.

  12. Noise-induced hearing loss: a recreational noise perspective.

    Science.gov (United States)

    Ivory, Robert; Kane, Rebecca; Diaz, Rodney C

    2014-10-01

    This review will discuss the real-world risk factors involved in noise-induced hearing loss as a result of common and popular recreational activities prone to mid and high levels of noise exposure. Although there are currently no interventional measures available to reverse or mitigate preexisting hearing loss from noise, we discuss the vital importance of hearing loss prevention from noise exposure avoidance and reduction. Despite a seeming understanding of the effects of noise exposure from various recreational activities and devices, a large percentage of the general public who is at risk of such noise-induced hearing loss still chooses to refrain from using hearing protection instruments. While occupational exposures pose the greatest traditional risk to hearing conservation in selected workers, recreational risk factors for noise-induced hearing loss may be more insidious in overall effect given the indifferent attitude of much of the general public and particularly our youths toward hearing protection during recreational activities. Active counseling regarding the consequences of excessive noise exposure and the potential benefits to hearing from usage of hearing protection instruments is critical to providing best possible care in the hearing health professions.

  13. Antimicrobial Peptide Lactoferricin B-Induced Rapid Leakage of Internal Contents from Single Giant Unilamellar Vesicles.

    Science.gov (United States)

    Moniruzzaman, Md; Alam, Jahangir Md; Dohra, Hideo; Yamazaki, Masahito

    2015-09-29

    Enzymatic digestion of bovine lactoferrin generates lactoferricin B (Lfcin B), a 25-mer peptide with strong antimicrobial activity of unknown mechanism. To elucidate the mechanistic basis of Lfcin B bactericidal activity, we investigated the interaction of Lfcin B with Escherichia coli and liposomes of lipid membranes. Lfcin B induced the influx of a membrane-impermeant fluorescent probe, SYTOX green, from the outside of E. coli into its cytoplasm. Lfcin B induced gradual leakage of calcein from large unilamellar vesicles (LUVs) of dioleoylphosphatidylglycerol (DOPG)/dioleoylphosphatidylcholine (DOPC) membranes. To clarify the cause of Lfcin B-induced leakage of calcein from the LUVs, we used the single giant unilamellar vesicle (GUV) method to investigate the interaction of Lfcin B with calcein-containing DOPG/DOPC-GUVs. We observed that a rapid leakage of calcein from a GUV started stochastically; statistical analysis provided a rate constant for Lfcin B-induced pore formation, kp. On the other hand, phase-contrast microscopic images revealed that Lfcin B induced a rapid leakage of sucrose from the single GUVs with concomitant appearance of a spherical GUV of smaller diameter. Because of the very fast leakage, and at the present time resolution of the experiments (33 ms), we could not follow the evolution of pore nor the process of the structural changes of the GUV. Here we used the term "local rupture" to express the rapid leakage of sucrose and determined the rate constant of local rupture, kL. On the basis of the comparison between kp and kL, we concluded that the leakage of calcein from single GUVs occurred as a result of a local rupture in the GUVs and that smaller pores inducing leakage of calcein were not formed before the local rupture. The results of the effect of the surface charge density of lipid membranes and that of salt concentration in buffer on kp clearly show that kp increases with an increase in the extent of electrostatic interactions due to

  14. Prevalence of occupational noise induced hearing loss amongst traffic police personnel

    OpenAIRE

    Singh, V K; Mehta, A K

    1999-01-01

    Traffic branch personnel of Pune traffic police were screened for presence of noise induced hearing loss. A very significant number (81.2%) showed sensorineural hearing loss. The various factors responsible for noise induced hearing loss are discussed.

  15. Microdose Induced Drain Leakage Effects in Power Trench MOSFETs: Experiment and Modeling

    Science.gov (United States)

    Zebrev, Gennady I.; Vatuev, Alexander S.; Useinov, Rustem G.; Emeliyanov, Vladimir V.; Anashin, Vasily S.; Gorbunov, Maxim S.; Turin, Valentin O.; Yesenkov, Kirill A.

    2014-08-01

    We study experimentally and theoretically the micro-dose induced drain-source leakage current in the trench power MOSFETs under irradiation with high-LET heavy ions. We found experimentally that cumulative increase of leakage current occurs by means of stochastic spikes corresponding to a strike of single heavy ion into the MOSFET gate oxide. We simulate this effect with the proposed analytic model allowing to describe (including Monte Carlo methods) both the deterministic (cumulative dose) and stochastic (single event) aspects of the problem. Based on this model the survival probability assessment in space heavy ion environment with high LETs was proposed.

  16. Decreased plasma levels of the endothelial protective sphingosine-1-phosphate are associated with dengue-induced plasma leakage

    NARCIS (Netherlands)

    Michels, M.; Japtok, L.; Alisjahbana, B.; Wisaksana, R.; Sumardi, U.; Puspita, M.; Kleuser, B.; Mast, Q. de; Ven, A.J.A.M. van der

    2015-01-01

    BACKGROUND: A transient endothelial hyperpermeability is a hallmark of severe dengue infections. Sphingosine-1-phosphate (S1P) maintains vascular integrity and protects against plasma leakage. We related plasma S1P levels to dengue-induced plasma leakage and studied mechanisms that may underlie the

  17. Study of radiation-induced leakage current between adjacent devices in a CMOS integrated circuit

    Institute of Scientific and Technical Information of China (English)

    Ding Lili; Guo Hongxia; Chen Wei; Fan Ruyu

    2012-01-01

    Radiation-induced inter-device leakage is studied using an analytical model and TCAD simulation.There were some different opinions in understanding the process of defect build-up in trench oxide and parasitic leakage path turning on from earlier studies.To reanalyze this problem and make it beyond argument,every possible variable is considered using theoretical analysis,not just the change of electric field or oxide thickness independently.Among all possible inter-device leakage paths,parasitic structures with N-well as both drain and source are comparatively more sensitive to the total dose effect when a voltage discrepancy exists between the drain and source region.Since N-well regions are commonly connected to the same power supply,these kinds of structures will not be a problem in a real CMOS integrated circuit.Generally speaking,conduction paths of inter-device leakage existing in a real integrated circuit and under real electrical circumstances are not very sensitive to the total ionizing dose effect.

  18. Minocycline attenuates noise-induced hearing loss in rats.

    Science.gov (United States)

    Zhang, Jing; Song, Yong-Li; Tian, Ke-Yong; Qiu, Jian-Hua

    2017-02-03

    Noise-induced hearing loss (NIHL) is a serious health concern and prevention of hair cell death or therapeutic intervention at the early stage of NIHL is critical to preserve hearing. Minocycline is a semi-synthetic derivative of tetracycline and has been shown to have otoprotective effects in ototoxic drug-induced hearing impairment, however, whether minocycline can protect against NIHL has not been investigated. The present study demonstrated elevated ABR (auditory brainstem response) thresholds and outer hair cell loss following traumatic noise exposure, which was mitigated by intraperitoneal administration of minocycline (45mg/kg/d) for 5 consecutive days. In conclusion, the present study demonstrated that minocycline, a clinically approved drug with a good safety profile, can attenuate NIHL in rats and may potentially be used for treatment of hearing loss in clinic. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Radiation induced leakage due to stochastic charge trapping in isolation layers of nanoscale MOSFETs

    Science.gov (United States)

    Zebrev, G. I.; Gorbunov, M. S.; Pershenkov, V. S.

    2008-03-01

    The sensitivity of sub-100 nm devices to microdose effects, which can be considered as intermediate case between cumulative total dose and single event errors, is investigated. A detailed study of radiation-induced leakage due to stochastic charge trapping in irradiated planar and nonplanar devices is developed. The influence of High-K insulators on nanoscale ICs reliability is discussed. Low critical values of trapped charge demonstrate a high sensitivity to single event effect.

  20. Prevention of the Evolution of Workers' Hearing Loss from Noise-Induced Hearing Loss in Noisy Environments through a Hearing Conservation Program

    OpenAIRE

    Fonseca, Vinicius Ribas; Marques, Jair; Panegalli, Flavio; Gonçalves, Claudia Giglio de Oliveira; Souza, Wesley

    2016-01-01

    Introduction Noise-induced hearing loss (NIHL) is a serious problem for workers and therefore for businesses. The hearing conservation program (HCP) is a set of coordinated measures to prevent the development or evolution of occupational hearing loss, which involves a continuous and dynamic process of implementation of hearing conservation routines through anticipation, recognition, evaluation, and subsequent control of the occurrence of existing environmental risks or of those thatmay exist...

  1. Mobile phone induced sensorineural hearing loss

    International Nuclear Information System (INIS)

    Al-Dousary, Surayie H.

    2007-01-01

    The increased use of mobile phones worldwide has focused interest on the biological effects and possible health outcomes of exposure to radiofrequency fields from mobile phones, and their base stations. Various reports suggest that mobile phone use can cause health problems like fatigue, headache, dizziness, tension and sleep disturbances, however, only limited research data is available in medical literature regarding interaction between electromagnetic fields emitted by mobile phones and auditory function and the possible impact on hearing. We report a case of sensorineural hearing loss due to Global System for Mobile Communication mobile phone use in a 42-year-old male. (author)

  2. Contemporary noise-induced hearing loss (NIHL) prevention.

    Science.gov (United States)

    Sułkowski, Wiesław; Owczarek, Kalina; Olszewski, Jurek

    2017-08-31

    Hearing impairment caused by noise, traditionally called - depending on the duration of exposure - acute or chronic acoustic trauma, includes, in addition to presbyacusis, the most common adult population of hearing impaired. In Poland - according to the report of the Central Statistical Office (GUS, 2011), the number of workers employed in NDN exceeded the noise level (85 dB) is about 200 thousand, the highest in the mining, metal and metal products production, textiles and wood production. According to the Regulation of the Council of Ministers of on June 30, 2009, on the list of occupational diseases (Journal of Laws No. 132, item 1115), it is defined as "bilateral permanent hearing loss of the cochlear or sensory-nerve type, expressed as an increase in hearing threshold of at least 45 dB in the ear better heard, calculated as an arithmetic mean for frequencies 1,2 and 3 kHz. Hearing impairments also occur in the military and police during field training and in combat where the source of acoustic injuries are firearms and pulse-inducing explosions (as in some industries) with high C peak levels (Lc peak) Time to rise to a maximum of <1 ms. The prevalence of loud music listening, particularly by personal stereo players, is also affecting children and adolescents with audiometric hearing loss, according to the World Health Organization (WHO) estimates of around 15-20%. The preventive action strategy is defined by the European Union legislation and the national implementing legislation that reduces or eliminates the risk and reduces (if not eliminated), taking into account available technical and organizational solutions to minimize the risk of hearing damage. If you can not reduce the noise levels with technical and organizational methods, you need individual hearing protectors. Ear protectors may be equipped with electronic systems with active noise reduction (which can improve low and medium frequency performance), adjustable attenuation (improves speech

  3. Leakage flow-induced vibrations for variations of a tube-in-tube slip joint

    International Nuclear Information System (INIS)

    Mulcahy, T.M.

    1986-01-01

    Variations in the design of a specific slip joint separating two cantilevered, telescoping tubes conveying water were studied to determine their effect upon the leakage flow-induced vibration self-excitation mechanism known to exist for the original slip joint geometry. The important parameters controlling the self-excitation mechanism were identified, which, along with previous results, allowed the determination of a comprehensive set of design rules to avoid unstable vibrations. This was possible even though a new self-excitation mechanism was found when the engagement of the two tubes was small. 9 refs

  4. Noise-induced hearing loss milestones: Past and future

    CSIR Research Space (South Africa)

    Edwards, A

    2011-01-01

    Full Text Available At the 2003 Mine Health and Safety Summit, the milestones for elimination of Noise-induced Hearing Loss (NIHL) in the mining industry were agreed on. The first milestone, December 2008, has passed and the next one in 2013 is looming. The study...

  5. Prevalence of noise induced hearing loss in textile industries in ...

    African Journals Online (AJOL)

    This cross sectional study measured the prevalence of Noise Induced Hearing Loss (NIHL) in textile industries in Dar Es Salaam city and Morogoro municipality. Data were collected from 125 employees randomly selected from each of the textile factory mill in each region through structured questionnaires and audiogram ...

  6. Prevalence and awareness of noise induced hearing loss in two ...

    African Journals Online (AJOL)

    Noise above a certain acceptable level or sustained noise may cause damage to the ears. The aim of this study is to determine the prevalence and level of awareness of noise induced hearing loss in Calabar. Seventy-five workers from two noise producing companies, in Calabar- Flour mill and Wartsilla were chosen for this ...

  7. [Natural history of occupational hearing loss induced by noise].

    Science.gov (United States)

    de Almeida, S I; Albernaz, P L; Zaia, P A; Xavier, O G; Karazawa, E H

    2000-01-01

    To evaluate the clinical and audiometric characteristics of occupational hearing loss induced by noise, according to age and time of exposition in years. 222 patients with occupational sensorineural hearing loss induced by noise were studied retrospectively, correlating the auditive clinical claims, alterations of audiometric thresholds at frequencies of 250 Hz to 8000 Hz, speech discrimination indicator with age and time of exposure. As a control group were used the audiometric threshold of a population of same medium age, without morbid antecedents of hearing illness, as preconized by ISO 1999 (1990). The group were divided into subgroups and three decades of exposure were analyzed. It was verified that the clinical claims of hipoacusia increases according to the age and time of exposure. The frequency of tinnitus is constant. The audiometric thresholds in the second decade of exposure present variations that depend on the age. The several audiometric curves are parallel, but they are not horizontal. The worst thresholds were found in the high frequencies from 3000 Hz to 8000 Hz, as a clinical and physiopathological consequences of the commitment of basal areas of cochlea. The speech discrimination showed to be worst according to the increase of age and time of exposure. Patients with hearing loss disacusia induced by occupational noise present characteristic audiometric thresholds that vary according to age and time of exposure to noise. These characteristics defined and resumed in audiometric curves can constitute a standard of comparison, evaluation and control for exposed populations.

  8. Noise-induced hearing loss: an occupational medicine perspective.

    Science.gov (United States)

    Stucken, Emily Z; Hong, Robert S

    2014-10-01

    Up to 30 million workers in the United States are exposed to potentially detrimental levels of noise. Although reliable medications for minimizing or reversing noise-induced hearing loss (NIHL) are not currently available, NIHL is entirely preventable. The purpose of this article is to review the epidemiology and pathophysiology of occupational NIHL. We will focus on at-risk populations and discuss prevention programs. Current prevention programs focus on reducing inner ear damage by minimizing environmental noise production and through the use of personal hearing protective devices. NIHL is the result of a complex interaction between environmental factors and patient factors, both genetic and acquired. The effects of noise exposure are specific to an individual. Trials are currently underway evaluating the role of antioxidants in protection from, and even reversal of, NIHL. Occupational NIHL is the most prevalent occupational disease in the United States. Occupational noise exposures may contribute to temporary or permanent threshold shifts, although even temporary threshold shifts may predispose an individual to eventual permanent hearing loss. Noise prevention programs are paramount in reducing hearing loss as a result of occupational exposures.

  9. Predicting hearing thresholds in occupational noise-induced hearing loss by auditory steady state responses.

    Science.gov (United States)

    Attias, Joseph; Karawani, Hanin; Shemesh, Rafi; Nageris, Ben

    2014-01-01

    Currently available behavioral tools for the assessment of noise-induced hearing loss (NIHL) depend on the reliable cooperation of the subject. Furthermore, in workers' compensation cases, there is considerable financial gain to be had from exaggerating symptoms, such that accurate assessment of true hearing threshold levels is essential. An alternative objective physiologic tool for assessing NIHL is the auditory steady state response (ASSR) test, which combines frequency specificity with a high level of auditory stimulation, making it applicable for the evaluation of subjects with a moderate to severe deficit. The primary aim of the study was to assess the value of the multifrequency ASSR test in predicting the behavioral warble-tone audiogram in a large sample of young subjects with NIHL of varying severity or with normal hearing. The secondary goal was to assess suprathreshold ASSR growth functions in these two groups. The study group included 157 subjects regularly exposed to high levels of occupational noise, who attended a university-associated audiological clinic for evaluation of NIHL from 2009 through 2011. All underwent a behavioral audiogram, and on the basis of the findings, were divided into those with NIHL (108 subjects, 216 ears) or normal hearing (49 subjects, 98 ears). The accuracy of the ASSR threshold estimations for frequencies of 500, 1000, 2000, and 4000 Hz was compared between groups, and the specificity and sensitivity of the ASSR test in differentiating ears with or without NIHL was calculated using receiver operating characteristic analysis. Linear regression analysis was used to formulate an equation to predict the behavioral warble-tone audiogram at each test frequency using ASSR thresholds. Multifrequency ASSR amplitude growth as a function of stimulus intensity was compared between the NIHL and normal-hearing groups for 1000 Hz and 4000 Hz carrier frequencies. In the subjects with NIHL, ASSR thresholds to various frequencies were

  10. [Progressive noise induced hearing loss caused by hearing AIDS, a dilemma for the worker and the expert alike].

    Science.gov (United States)

    Feldmann, H

    2001-12-01

    Investigating cases of noise induced hearing loss the expert is often confronted with the situation that the hearing loss is progressive although the noise exposure has been reduced to almost non-damaging levels. Other causes such as age, hereditary deafness, head injuries, blasts, internal diseases can be excluded. Hearing aids as sources of damaging noise? By consulting the protocol of the hearing-aid acoustician and by own examinations the expert should obtain the following data: loudness level that yields best discrimination score of speech; level of discomfort for tones and speech, discrimination score that is achieved under free field condition with a speech level of 65 dB, using the hearing aids. Furthermore he should explore the circumstances under which the hearing aids are used: how many hours per day, at what occasions etc.? It is likely that in using the hearing aids they are adjusted to emit an intensity level identical to the one yielding the optimal discrimination score. If this e. g. is 100 dB and the hearing aids are used for 2 hours per day this would be equivalent to an exposure to industrial noise of 94 dB (A) for 8 hours daily without ear protection. Among all individuals working under industrial noise exposure today only about 1 - 2 % having unusually vulnerable inner ears will suffer a noise induced hearing loss. On the other hand workers in industrial noise are accustomed to loud noise levels, usually have a raised threshold of discomfort and therefore are likely to adjust their hearing aids to such high intensities. The expert will have to decide whether in an individual case the industrial noise exposure or the use of the hearing aids is the dominant risk for further damage. The consequences in respect to the regulations of the workers' health insurance are discussed.

  11. Noise induced hearing loss and other hearing complaints among musicians of symphony orchestras

    NARCIS (Netherlands)

    Jansen, E. J. M.; Helleman, H. W.; Dreschler, W. A.; de Laat, J. A. P. M.

    2009-01-01

    OBJECTIVES: An investigation of the hearing status of musicians of professional symphony orchestras. Main questions are: (1) Should musicians be treated as a special group with regard to hearing, noise, and noise related hearing problems (2) Do patterns of hearing damage differ for different

  12. Toluene-induced hearing loss in the guinea pig.

    Science.gov (United States)

    Waniusiow, Delphine; Campo, Pierre; Venet, Thomas; Cossec, Benoît; Cosnier, Frédéric; Beydon, Dominique; Rieger, Benoît; Burgart, Manuella; Ferrari, Luc; Parietti-Winkler, Cécile

    2009-10-01

    Toluene is a high-production industrial solvent, which can disrupt the auditory system in rats. However, toluene-induced hearing loss is species dependent. For instance, despite long-lasting exposures to high concentrations of aromatic solvent, no study has yet succeeded in causing convincing hearing loss in the guinea pig. This latter species can be characterized by two metabolic particularities: a high amount of hepatic cytochrome P-450s (P-450s) and a high concentration of glutathione in the cochlea. It is therefore likely that the efficiency of both the hepatic and cochlear metabolisms plays a key role in the innocuousness of the hearing of guinea pigs to exposure to solvent. The present study was carried out to test the auditory resistance to toluene in glutathione-depleted guinea pigs whose the P-450 activity was partly inhibited. To this end, animals on a low-protein diet received a general P-450 inhibitor, namely SKF525-A. Meanwhile, they were exposed to 1750 ppm toluene for 4 weeks, 5 days/week, 6 h/day. Auditory function was tested by electrocochleography and completed by histological analyses. For the first time, a significant toluene-induced hearing loss was provoked in the P-450-inhibited guinea pigs. However, the ototoxic process caused by the solvent exposure was different from that observed in the rat. Only the stria vascularis and the spiral fibers were disrupted in the apical coil of the cochlea. The protective mechanisms developed by guinea pigs are discussed in the present publication.

  13. Comparison of thermally induced and naturally occurring water-borne leakages from hard rock depositories for radioactive waste

    International Nuclear Information System (INIS)

    Bourke, P.J.; Robinson, P.C.

    1981-01-01

    The relative importance of thermally induced and naturally occurring flows of water as causes of leakage from hard rock depositories for radioactive wastes is assessed. Separate analyses are presented for involatile, high level waste from reprocessing of fuel and for plutonium contaminated waste from fabrication of fuel. The effects of varying the quantities of wastes, pre-burial storage and the shapes and depths of depositories are considered. It is concluded that for representative values of these variables, thermal flow will remain the major cause of leakage for long times after the burial of both types of waste. (Auth.)

  14. Prevention of the Evolution of Workers' Hearing Loss from Noise-Induced Hearing Loss in Noisy Environments through a Hearing Conservation Program.

    Science.gov (United States)

    Fonseca, Vinicius Ribas; Marques, Jair; Panegalli, Flavio; Gonçalves, Claudia Giglio de Oliveira; Souza, Wesley

    2016-01-01

    Introduction Noise-induced hearing loss (NIHL) is a serious problem for workers and therefore for businesses. The hearing conservation program (HCP) is a set of coordinated measures to prevent the development or evolution of occupational hearing loss, which involves a continuous and dynamic process of implementation of hearing conservation routines through anticipation, recognition, evaluation, and subsequent control of the occurrence of existing environmental risks or of those that may exist in the workplace and lead to workers' hearing damage. Objective The aim of this study was to evaluate the effectiveness of the HCP in preventing further hearing loss in workers with audiograms suggestive of NIHL. The audiometric tests and medical records of 28 furniture company workers exposed to noise were reviewed and monitored for 2 years. Methods This retrospective, cross-sectional study examined five audiometric tests in the medical records (on admission and every semester) of 28 workers in a furniture company (totaling 140 audiometric exams) following the introduction of the HCP. Results Data analysis showed no differences between the audiometric tests conducted on admission and those performed every semester. Conclusions The HCP implemented was effective in preventing the worsening of hearing loss in workers already with NIHL when exposed to occupational noise. Therefore, such a measure could be useful for the employment of workers with hearing loss in job sectors that have noise exposure.

  15. Prevention of the Evolution of Workers' Hearing Loss from Noise-Induced Hearing Loss in Noisy Environments through a Hearing Conservation Program

    Science.gov (United States)

    Fonseca, Vinicius Ribas; Marques, Jair; Panegalli, Flavio; Gonçalves, Claudia Giglio de Oliveira; Souza, Wesley

    2015-01-01

    Introduction Noise-induced hearing loss (NIHL) is a serious problem for workers and therefore for businesses. The hearing conservation program (HCP) is a set of coordinated measures to prevent the development or evolution of occupational hearing loss, which involves a continuous and dynamic process of implementation of hearing conservation routines through anticipation, recognition, evaluation, and subsequent control of the occurrence of existing environmental risks or of those that may exist in the workplace and lead to workers' hearing damage. Objective The aim of this study was to evaluate the effectiveness of the HCP in preventing further hearing loss in workers with audiograms suggestive of NIHL. The audiometric tests and medical records of 28 furniture company workers exposed to noise were reviewed and monitored for 2 years. Methods This retrospective, cross-sectional study examined five audiometric tests in the medical records (on admission and every semester) of 28 workers in a furniture company (totaling 140 audiometric exams) following the introduction of the HCP. Results Data analysis showed no differences between the audiometric tests conducted on admission and those performed every semester. Conclusions The HCP implemented was effective in preventing the worsening of hearing loss in workers already with NIHL when exposed to occupational noise. Therefore, such a measure could be useful for the employment of workers with hearing loss in job sectors that have noise exposure. PMID:26722345

  16. Noise Induced Hearing Loss in Iran: (1997–2012): Systematic Review Article

    Science.gov (United States)

    SOLTANZADEH, Ahmad; EBRAHIMI, Hossein; FALLAHI, Majid; KAMALINIA, Mojtaba; GHASSEMI, Shadi; GOLMOHAMMADI, Rostam

    2014-01-01

    Noise-induced hearing loss, which is one of the 10 leading occupational diseases, is a debilitating and irreversible disease. During the recent 15-years period (1997–2012), several studies have investigated the association between noise, hearing damage and other side effects of noise in Iran. The aim of this study was to review systematically the relevant literature related to noise-induced hearing loss, lead to developing noise exposure limits. In this systematic review, two researchers independently extracted the data from 31 past studies that had considered noise-induced hearing loss (including hearing loss, temporary and permanent hearing threshold shift and auditory trauma). The data were then recorded in a modified form and Statistical analyses were performed using SPSS, version 16.0. In analyzed studies the weighted average equivalent sound pressure level [L Aeq ] was 90.29 dB(A) and average hearing loss was 26.44 dB(A). The Highest degree of hearing loss in the right ear was associated at 4000 Hz, and the highest degree of hearing loss in the left ear was associated to 1000 and 4000 Hz. The majority of the reviewed studies have confirmed that exposure to a noise level above 85 dB (A) can lead to an increased chance of hearing loss. Furthermore, the results of the present review indicated that as L Aeq increased up to 85 dB(A), so did the severity of the hearing loss. PMID:26171352

  17. The use of hearing protection devices with approach risk perception of noise induced hearing loss in several manufacturing industry

    Directory of Open Access Journals (Sweden)

    Behzad Fouladi Deahghi

    2015-06-01

    Full Text Available Background & Objective : Noise is a widespread physical agent and although is a most risk factors in workplaces that workers of health to exposed. Thus, different actions is done for reduce exposure to it in work places, which one of them is use of hearing protection devices. The use of hearing protection devices with approach risk perception of noise induced hearing loss in several manufacturing industry Method: This study was Cross-sectional study and done in five industrial unit with a sound pressure level more of 85 dB-A with the participation of 340 workers. To collect data , individual risk perception and self-investigator questionnaires were used. After collecting data, statistical analysis including Cronbach's alpha and regression were used to analyze the data. Results : Range use of hearing protection devices during shifts work by workers, respectively equal to: 50.4% sometimes, 31.58% never and 18.2% at all times. Also, results indicate significant differences between individual differences and hearing protection devices. Conclusion : Results of this study showed that individual risk perception as an important factor, can do a significant role in predicting the behavior of personals in the use of hearing protection devices, which should be considered in any design and implementation of hearing protection program.

  18. Constraint-induced sound therapy for sudden sensorineural hearing loss – behavioral and neurophysiological outcomes

    OpenAIRE

    Hidehiko Okamoto; Munehisa Fukushima; Henning Teismann; Lothar Lagemann; Tadashi Kitahara; Hidenori Inohara; Ryusuke Kakigi; Christo Pantev

    2014-01-01

    Sudden sensorineural hearing loss is characterized by acute, idiopathic hearing deterioration. We report here the development and evaluation of “constraint-induced sound therapy”, which is based on a well-established neuro-rehabilitation approach, and which is characterized by the plugging of the intact ear (“constraint”) and the simultaneous, extensive stimulation of the affected ear with music. The sudden sensorineural hearing loss patients who received the constraint-induced sound therapy ...

  19. Laser-induced capillary leakage for blood biomarker detection and vaccine delivery via the skin.

    Science.gov (United States)

    Wu, Jeffrey H; Li, Bo; Wu, Mei X

    2016-07-01

    Circulation system is the center for coordination and communication of all organs in our body. Examination of any change in its analytes or delivery of therapeutic drugs into the system consists of important medical practice in today's medicine. Two recent studies prove that brief illumination of skin with a low powered laser, at wavelengths preferentially absorbed by hemoglobin, increases the amount of circulating biomarkers in the epidermis and upper dermis by more than 1,000-fold. When probe-coated microneedle arrays are applied into laser-treated skin, plasma blood biomarkers can be reliably, accurately, and sufficiently quantified in 15∼30 min assays, with a maximal detection in one hr in a manner independent of penetration depth or a molecular mass of the biomarker. Moreover, the laser treatment permits a high efficient delivery of radiation-attenuated malarial sporozoites (RAS) into the circulation, leading to robust immunity against malaria infections, whereas similar immunization at sham-treated skin elicits poor immune responses. Thus this technology can potentially instruct designs of small, portable devices for onsite, in mobile clinics, or at home for point-of-care diagnosis and drug/vaccine delivery via the skin. Laser-induced capillary leakage (a) to induce extravasation of circualing molecules only (b) or facilitate entry of attenuated malaria sporozoites into the capillary (c). Skin illumination with a laser preferably absorbed by hemoglobin causes dilation of the capillary beneath the skin. The extravasated molecules can be sufficiently measured in the skin or guide sporozoites to enter the vessel. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Cochlear Synaptopathy and Noise-Induced Hidden Hearing Loss

    Directory of Open Access Journals (Sweden)

    Lijuan Shi

    2016-01-01

    Full Text Available Recent studies on animal models have shown that noise exposure that does not lead to permanent threshold shift (PTS can cause considerable damage around the synapses between inner hair cells (IHCs and type-I afferent auditory nerve fibers (ANFs. Disruption of these synapses not only disables the innervated ANFs but also results in the slow degeneration of spiral ganglion neurons if the synapses are not reestablished. Such a loss of ANFs should result in signal coding deficits, which are exacerbated by the bias of the damage toward synapses connecting low-spontaneous-rate (SR ANFs, which are known to be vital for signal coding in noisy background. As there is no PTS, these functional deficits cannot be detected using routine audiological evaluations and may be unknown to subjects who have them. Such functional deficits in hearing without changes in sensitivity are generally called “noise-induced hidden hearing loss (NIHHL.” Here, we provide a brief review to address several critical issues related to NIHHL: (1 the mechanism of noise induced synaptic damage, (2 reversibility of the synaptic damage, (3 the functional deficits as the nature of NIHHL in animal studies, (4 evidence of NIHHL in human subjects, and (5 peripheral and central contribution of NIHHL.

  1. Pitch and Loudness from Tinnitus in Individuals with Noise-induced Hearing Loss

    Directory of Open Access Journals (Sweden)

    Flores, Leticia Sousa

    2015-08-01

    Full Text Available Introduction Tinnitus is one of the symptoms that affects individuals suffering from noise induced hearing loss. This condition can be disabling, leading the affected individual to turn away from work. Objective This literature review aims to analyze the possible association between gender and tinnitus pitch and loudness, the degree of hearing loss and the frequencies affected in subjects with noise-induced hearing loss. Methods This contemporary cohort study was conducted through a cross-sectional analysis. The study sample consisted of adults with unilateral or bilateral tinnitus, who had been diagnosed with noise-induced hearing loss. The patients under analysis underwent an otorhinolaryngological evaluation, pure tone audiometry, and acuphenometry. Results The study included 33 subjects with noise-induced hearing loss diagnoses, of which 22 (66.7% were men. Authors observed no statistical difference between gender and loudness/pitch tinnitus and loudness/pitch in subjects with bilateral tinnitus. Authors found an inverse relation between tinnitus loudness with intensity greater hearing threshold and the average of the thresholds and the grade of hearing loss. The tinnitus pitch showed no association with higher frequency of hearing threshold. Conclusion Data analysis shows that, among the individuals evaluated, the greater the hearing loss, the lower the loudness of tinnitus. We did not observe an association between hearing loss and tinnitus pitch.

  2. Historical review of efforts to reduce noise-induced hearing loss in the United States.

    Science.gov (United States)

    Kerr, Madeleine J; Neitzel, Richard L; Hong, OiSaeng; Sataloff, Robert T

    2017-06-01

    Noise-induced hearing loss is a centuries-old problem that is still prevalent in the United States and worldwide. To describe highlights in the development of hearing loss prevention in the U.S. from World War II to the present. Literature review. Approaches to occupational noise-induced hearing loss prevention in the United States over the past seven decades are described using a hierarchy of controls framework and an interdisciplinary perspective. Historical timelines and developmental milestones related to occupational noise-induced hearing loss prevention are summarized as a life course. Lessons are drawn for other countries in their hearing conservation efforts. Future developments building on the hearing loss prevention work of the past 70 years can prevent the problem of occupational NIHL in the 21st century. Am. J. Ind. Med. 60:569-577, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  3. Parametrization of the radiation induced leakage current increase of NMOS transistors

    International Nuclear Information System (INIS)

    Backhaus, M.

    2017-01-01

    The increase of the leakage current of NMOS transistors during exposure to ionizing radiation is known and well studied. Radiation hardness by design techniques have been developed to mitigate this effect and have been successfully used. More recent developments in smaller feature size technologies do not make use of these techniques due to their drawbacks in terms of logic density and requirement of dedicated libraries. During operation the resulting increase of the supply current is a serious challenge and needs to be considered during the system design. A simple parametrization of the leakage current of NMOS transistors as a function of total ionizing dose is presented. The parametrization uses a transistor transfer characteristics of the parasitic transistor along the shallow trench isolation to describe the leakage current of the nominal transistor. Together with a parametrization of the number of positive charges trapped in the silicon dioxide and number of activated interface traps in the silicon to silicon dioxide interface the leakage current results as a function of the exposure time to ionizing radiation. This function is fitted to data of the leakage current of single transistors as well as to data of the supply current of full ASICs.

  4. Cellular mechanisms of noise-induced hearing loss.

    Science.gov (United States)

    Kurabi, Arwa; Keithley, Elizabeth M; Housley, Gary D; Ryan, Allen F; Wong, Ann C-Y

    2017-06-01

    Exposure to intense sound or noise can result in purely temporary threshold shift (TTS), or leave a residual permanent threshold shift (PTS) along with alterations in growth functions of auditory nerve output. Recent research has revealed a number of mechanisms that contribute to noise-induced hearing loss (NIHL). The principle cause of NIHL is damage to cochlear hair cells and associated synaptopathy. Contributions to TTS include reversible damage to hair cell (HC) stereocilia or synapses, while moderate TTS reflects protective purinergic hearing adaptation. PTS represents permanent damage to or loss of HCs and synapses. While the substrates of HC damage are complex, they include the accumulation of reactive oxygen species and the active stimulation of intracellular stress pathways, leading to programmed and/or necrotic cell death. Permanent damage to cochlear neurons can also contribute to the effects of NIHL, in addition to HC damage. These mechanisms have translational potential for pharmacological intervention and provide multiple opportunities to prevent HC damage or to rescue HCs and spiral ganglion neurons that have suffered injury. This paper reviews advances in our understanding of cellular mechanisms that contribute to NIHL and their potential for therapeutic manipulation. Published by Elsevier B.V.

  5. [Transcultural adaptation of an instrument to evaluate hearing handicap in workers with noise-induced hearing loss].

    Science.gov (United States)

    Holanda, Wanessa Tenório Gonçalves; de Lima, Maria Luiza Carvalho; Figueiroa, José Natal

    2011-01-01

    The noise-induced hearing loss (NIHL) is a chronic and irreversible disease resulting of the exposure to noise in high levels at work. Even in the beginning, this hearing loss can damage in many degrees the worker's quality of life. Before this study, there wasn't an instrument, in Portuguese, to evaluate the psychosocial disadvantages of workers with NIHL. The aim of this research was to make a transcultural adaptation of an especific instrument to evaluate the hearing handicap from the original language to Portuguese, and check the reliability and legitimacy. The selected instrument passed by a process of semantic equivalence that was conducted in five stages: translation, back translation, critical appraisal of the versions, pre-test and a final review by a multi-professional group to develop a consensual version of the instrument for current use in Brazil. The instrument called "Inabilities Scale and Hearing Handicap" had, in general, acceptable psychometric measures, considering the little size of the sample and the fact that workers' hearing loss weren't too significant. Therefore, the Portuguese version of this instrument needs to be further tested in a representative sample of Brazilian workers with NIHL to ratify its utility in order to evaluate hearing handicap in this population.

  6. Interventions to prevent occupational noise-induced hearing loss

    NARCIS (Netherlands)

    Verbeek, Jos H.; Kateman, Erik; Morata, Thais C.; Dreschler, Wouter A.; Mischke, Christina

    2012-01-01

    Background Millions of workers worldwide are exposed to noise levels that increase their risk of hearing impairment. Little is known about the effectiveness of hearing loss prevention interventions. Objectives To assess the effectiveness of non-pharmaceutical interventions for preventing

  7. Interventions to prevent occupational noise induced hearing loss

    NARCIS (Netherlands)

    Verbeek, Jos H.; Kateman, Erik; Morata, Thais C.; Dreschler, Wout; Sorgdrager, Bas

    2009-01-01

    BACKGROUND: Millions of workers worldwide are exposed to noise levels that increase their risk of hearing impairment. Little is known about the effectiveness of hearing loss prevention interventions. OBJECTIVES: To assess the effectiveness of non-pharmaceutical interventions for preventing

  8. Parametrization of the radiation induced leakage current increase of NMOS transistors

    CERN Document Server

    Backhaus, Malte

    2017-01-13

    The increase of the leakage current of NMOS transistors during exposure to ionizing radiation is known and well studied. Radiation hardness by design techniques have been developed to mitigate this effect and have been successfully used. More recent developments in smaller feature size technologies do not make use of these techniques due to their drawbacks in terms of logic density and requirement of dedicated libraries. During operation the resulting increase of the supply current is a serious challenge and needs to be considered during the system design. A simple parametrization of the leakage current of NMOS transistors as a function of total ionizing dose is presented. The parametrization uses a transistor transfer characteristics of the parasitic transistor along the shallow trench isolation to describe the leakage current of the nominal transistor. Together with a parametrization of the number of positive charges trapped in the silicon dioxide and number of activated interface traps in the silicon to si...

  9. Noise-Induced Hearing Loss - A Preventable Disease?

    DEFF Research Database (Denmark)

    Frederiksen, Thomas W.; Ramlau-Hansen, Cecilia H.; Stokholm, Zara A.

    2017-01-01

    AIMS: To survey current, Danish industrial noise levels and the use of hearing protection devices (HPD) over a 10-year period and to characterise the association between occupational noise and hearing threshold shift in the same period. Furthermore, the risk of hearing loss among the baseline and...

  10. Noise Induced Hearing Loss Among Cotton Textile and Carpet Mill Workers

    OpenAIRE

    ERTEM, Melikşah

    1998-01-01

    In industry increased mechanisation results in increased noise levels. Operation of textile machines carries a high risk of hearing loss. In this study the evaluation of textile worker's noise induced hearing loss was reviewed cross sectionally. The hearing of 260 textile workers exposed to noise levels between 85-95 dB(A) in carpet and cotton textile factories was assessed by means of air and bone conductance audiograms obtained. The subjects were grouped into five hearin...

  11. CO2 leakage-induced vegetation decline is primarily driven by decreased soil O2.

    Science.gov (United States)

    Zhang, Xueyan; Ma, Xin; Zhao, Zhi; Wu, Yang; Li, Yue

    2016-04-15

    To assess the potential risks of carbon capture and storage (CCS), studies have focused on vegetation decline caused by leaking CO2. Excess soil CO2 caused by leakage can affect soil O2 concentrations and soil pH, but how these two factors affect plant development remains poorly understood. This hinders the selection of appropriate species to mitigate potential negative consequences of CCS. Through pot experiments, we simulated CO2 leakage to examine its effects on soil pH and soil O2 concentrations. We subsequently assessed how maize growth responded to these changes in soil pH and O2. Decreased soil O2 concentrations significantly reduced maize biomass, and explained 69% of the biomass variation under CO2 leakage conditions. In contrast, although leaked CO2 changed soil pH significantly (from 7.32 to 6.75), it remained within the optimum soil pH range for maize growth. This suggests that soil O2 concentration, not soil pH, influences plant growth in these conditions. Therefore, in case of potential CO2 leakage risks, hypoxia-tolerant species should be chosen to improve plant survival, growth, and yield. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Band to Band Tunneling (BBT) Induced Leakage Current Enhancement in Irradiated Fully Depleted SOI Devices

    Science.gov (United States)

    Adell, Phillipe C.; Barnaby, H. J.; Schrimpf, R. D.; Vermeire, B.

    2007-01-01

    We propose a model, validated with simulations, describing how band-to-band tunneling (BBT) affects the leakage current degradation in some irradiated fully-depleted SOI devices. The dependence of drain current on gate voltage, including the apparent transition to a high current regime is explained.

  13. Chronic lead exposure induces cochlear oxidative stress and potentiates noise-induced hearing loss.

    Science.gov (United States)

    Jamesdaniel, Samson; Rosati, Rita; Westrick, Judy; Ruden, Douglas M

    2018-08-01

    Acquired hearing loss is caused by complex interactions of multiple environmental risk factors, such as elevated levels of lead and noise, which are prevalent in urban communities. This study delineates the mechanism underlying lead-induced auditory dysfunction and its potential interaction with noise exposure. Young-adult C57BL/6 mice were exposed to: 1) control conditions; 2) 2 mM lead acetate in drinking water for 28 days; 3) 90 dB broadband noise 2 h/day for two weeks; and 4) both lead and noise. Blood lead levels were measured by inductively coupled plasma mass spectrometry analysis (ICP-MS) lead-induced cochlear oxidative stress signaling was assessed using targeted gene arrays, and the hearing thresholds were assessed by recording auditory brainstem responses. Chronic lead exposure downregulated cochlear Sod1, Gpx1, and Gstk1, which encode critical antioxidant enzymes, and upregulated ApoE, Hspa1a, Ercc2, Prnp, Ccl5, and Sqstm1, which are indicative of cellular apoptosis. Isolated exposure to lead or noise induced 8-12 dB and 11-25 dB shifts in hearing thresholds, respectively. Combined exposure induced 18-30 dB shifts, which was significantly higher than that observed with isolated exposures. This study suggests that chronic exposure to lead induces cochlear oxidative stress and potentiates noise-induced hearing impairment, possibly through parallel pathways. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  14. Noise induced hearing loss: Screening with pure-tone audiometry and speech-in-noise testing

    NARCIS (Netherlands)

    Leensen, M.C.J.

    2013-01-01

    Noise-induced hearing loss (NIHL) is a highly prevalent public health problem, caused by exposure to loud noises both during leisure time, e.g. by listening to loud music, and during work. In the past years NIHL was the most commonly reported occupational disease in the Netherlands. Hearing damage

  15. Ethylbenzene-induced hearing loss, neurobehavioral function, and neurotransmitter alterations in petrochemical workers.

    Science.gov (United States)

    Zhang, Ming; Wang, Yanrang; Wang, Qian; Yang, Deyi; Zhang, Jingshu; Wang, Fengshan; Gu, Qing

    2013-09-01

    To estimate hearing loss, neurobehavioral function, and neurotransmitter alteration induced by ethylbenzene in petrochemical workers. From two petrochemical plants, 246 and 307 workers exposed to both ethylbenzene and noise were recruited-290 workers exposed to noise only from a power station plant and 327 office personnel as control group, respectively. Hearing and neurobehavioral functions were evaluated. Serum neurotransmitters were also determined. The prevalence of hearing loss was much higher in petrochemical groups than that in power station and control groups (P workers (P hearing loss, neurobehavioral function impairment, and imbalance of neurotransmitters.

  16. [Criteria for the assessment of the noise-induced occupational hearing loss: international and national standards].

    Science.gov (United States)

    Izmerov, N F; Denisov, É I; Adeninskaia, E E; Gorblianskiĭ, Iu Iu

    2014-01-01

    The objective of the present paper was to review international and national standards for the criteria of assessment of the noise-induced occupational loss of hearing. The importance of healthy hearing for the occupational safety is emphasized which implies the necessity of the more rigorous criteria for hearing conservation in the workers engaged in the noisy technological environment compared with those for the general population. A rationale for the development of the standard program of hearing conservation in the workers engaged in the noisy technological environment is proposed including hygienic norms and rules or national state standards.

  17. Novel method of evaluating miners at risk for noise-induced hearing loss

    CSIR Research Space (South Africa)

    Edwards, AL

    2010-08-31

    Full Text Available Noise-induced hearing loss (NIHL) negatively affects the quality of life of mine employees and costs mining companies large amounts in compensation claims. The prevention of NIHL requires early identification and recent evidence about the ability...

  18. Sex Differences in Susceptibility and Resistance to Noise-Induced Hearing Loss in Chinchillas

    National Research Council Canada - National Science Library

    McFadden, Sandra

    1999-01-01

    .... The reasons for individual differences in susceptibility to noise-induced hearing loss (NIHL) are largely unknown, but may include factors such as levels of endogenous antioxidant enzymes or steroid hormones...

  19. Interventions to prevent occupational noise-induced hearing loss

    NARCIS (Netherlands)

    Tikka, Christina; Verbeek, Jos H.; Kateman, Erik; Morata, Thais C.; Dreschler, Wouter A.; Ferrite, Silvia

    2017-01-01

    This is the second update of a Cochrane Review originally published in 2009. Millions of workers worldwide are exposed to noise levels that increase their risk of hearing disorders. There is uncertainty about the effectiveness of hearing loss prevention interventions. To assess the effectiveness of

  20. Noise-Induced Hearing Impairment As An Occupational Risk Factor ...

    African Journals Online (AJOL)

    Noise pollution in workplaces poses serious health risks including that of cardiovascular disturbances and impairment of hearing. The objective of this study was to assess the effects of occupational noise on hearing among selected industrial workers in Benin City, Nigeria. Male and female workers (n=150) in sawmills, ...

  1. The noise-induced hearing loss milestones: past and future

    CSIR Research Space (South Africa)

    Edwards, AL

    2012-10-01

    Full Text Available sought to answer the questions: Did we reach the 2008 milestone? What should the industry do now about hearing conservation that will ensure that there is no deterioration in hearing greater than 10% amongst noise-exposed miners? How can we ensure...

  2. High-frequency audiometry: A means for early diagnosis of noise-induced hearing loss

    Directory of Open Access Journals (Sweden)

    Amir H Mehrparvar

    2011-01-01

    Full Text Available Noise-induced hearing loss (NIHL, an irreversible disorder, is a common problem in industrial settings. Early diagnosis of NIHL can help prevent the progression of hearing loss, especially in speech frequencies. For early diagnosis of NIHL, audiometry is performed routinely in conventional frequencies. We designed this study to compare the effect of noise on high-frequency audiometry (HFA and conventional audiometry. In a historical cohort study, we compared hearing threshold and prevalence of hearing loss in conventional and high frequencies of audiometry among textile workers divided into two groups: With and without exposure to noise more than 85 dB. The highest hearing threshold was observed at 4000 Hz, 6000 Hz and 16000 Hz in conventional right ear audiometry, conventional left ear audiometry and HFA in each ear, respectively. The hearing threshold was significantly higher at 16000 Hz compared to 4000. Hearing loss was more common in HFA than conventional audiometry. HFA is more sensitive to detect NIHL than conventional audiometry. It can be useful for early diagnosis of hearing sensitivity to noise, and thus preventing hearing loss in lower frequencies especially speech frequencies.

  3. Occupational noise-induced hearing loss in Indian steel industry workers: an exploratory study.

    Science.gov (United States)

    Singh, Lakhwinder Pal; Bhardwaj, Arvind; Deepak, Kishore Kumar

    2013-04-01

    The present study focused on exploring the current level of hearing protection and subsequently determined the prevalence of occupational noise-induced hearing loss among casting and forging industry workers. The casting and forging industry provides employment to a significant portion of the population. The level of hearing protection was assessed through questionnaire survey of 572 workers. Out of these workers, 165 and another control group of 57 participants were assessed by formal audiometry. Audiometric tests were conducted at frequencies of 1.0 KHz to 8.0 KHz.The occurrence of hearing loss was determined on the basis of a hearing threshold level with a low fence of 25 dB. Student's test and ANOVA were used to compare the various groups; a p value steel industry are highly exposed to occupational noise. The majority of workers are not protected from noise-induced hearing loss. There is a need to provide special ear protectors for workers engaged in forging. A complete hearing protection program, including training, audiometry, job rotation, and the use of hearing protection devices, needs to be introduced.

  4. Quantitative single-vesicle analysis of antimicrobial peptide-induced leakage

    DEFF Research Database (Denmark)

    Kristensen, Kasper; Ehrlich, Nicky; Henriksen, Jonas Rosager

    2013-01-01

    Although the research field of antimicrobial peptides has attracted considerable scientific attention in the past decades, the microbicidal mechanisms of antimicrobial peptides still remain elusive. One of the keys to a more profound comprehension of the function of these peptides is a deeper...... was combined with fluorescence correlation spectroscopy to quantify leakage from a bulk collection of lipid vesicles in aqueous solution. Quantitative correlation between the two techniques was achieved through a detailed experimental protocol. The potential of combining the two techniques was tested using...

  5. Prevalence of noise-induced hearing loss in drivers

    Directory of Open Access Journals (Sweden)

    Andréa Cintra Lopes1, , , ,

    2012-01-01

    Full Text Available Introduction: Work-related hearing loss is one of the most common occupational illness progresses over the years of noise exposure associated with the work environment, may cause damage to undertake physical activity, the individual's physiological and mental besides causing hearing damage irreversible interfering with communication and quality of life. With high prevalence of male evaluates which is the second leading cause of hearing loss. Since there is no medical treatment for this type of hearing loss, it is evident the importance of preventive and conferences aimed at preserving hearing and health as a whole. Objective: To assess the prevalence of hearing loss in audiometry admission of drivers. Methods: Retrospective study. By 76 charts of professional drivers in leased transport companies. We analyzed data from specific interview and pure tone audiometry. Results: The prevalence of abnormal tests was 22.36% with the lowest thresholds for tritonal average of 3,000, 4,000 and 6,000 Hz. The higher the age, the higher thresholds. Conclusion: This study has highlighted the occurrence of hearing in the absence of complaints. Considering that PAIR is preventable, justifies the importance of coordinated and multidisciplinary involving not only health teams and safety, but also the institutions involved in preserving the health of workers, as the team SESMET, unions or prosecutors.

  6. Noise-Induced Hearing Loss (NIHL: literature review with a focus on occupational medicine

    Directory of Open Access Journals (Sweden)

    Metidieri, Mirella Melo

    2013-04-01

    Full Text Available According to the Ministry of Health (2006, Noise-Induced Hearing Loss (NIHL is hearing loss caused by prolonged exposure to noise. It is characterized as sensorineural hearing loss and is usually bilateral, irreversible, and progressive while the exposure to noise continues. A NIHL is a predictable and preventable disease with an epidemiologically relevant prevalence in urban communities. The hearing loss begins and predominates in the frequencies of 3, 4, and 6 kHz and eventually progresses to 8, 2, 1, 0.5, and 0.25 kHz. In Brazil, regulatory standard 15 limits the exposure to continuous noise to no more than 4 hours' exposure to 90 dBA and a maximum level of 85 dB for a full 8-hour working period. As NIHL is a preventable and predictable disease, preventive action by professionals may be able to change the prevalence of hearing loss in noisy environments.

  7. Noise-Induced Hearing Loss (NIHL): literature review with a focus on occupational medicine.

    Science.gov (United States)

    Metidieri, Mirella Melo; Rodrigues, Hugo Fernandes Santos; Filho, Francisco José Motta Barros de Oliveira; Ferraz, Daniela Pereira; Neto, Antonio Fausto de Almeida; Torres, Sandro

    2013-04-01

    According to the Ministry of Health (2006), Noise-Induced Hearing Loss (NIHL) is hearing loss caused by prolonged exposure to noise. It is characterized as sensorineural hearing loss and is usually bilateral, irreversible, and progressive while the exposure to noise continues. A NIHL is a predictable and preventable disease with an epidemiologically relevant prevalence in urban communities. The hearing loss begins and predominates in the frequencies of 3, 4, and 6 kHz and eventually progresses to 8, 2, 1, 0.5, and 0.25 kHz. In Brazil, regulatory standard 15 limits the exposure to continuous noise to no more than 4 hours' exposure to 90 dBA and a maximum level of 85 dB for a full 8-hour working period. As NIHL is a preventable and predictable disease, preventive action by professionals may be able to change the prevalence of hearing loss in noisy environments.

  8. Occupational noise-induced hearing loss in auto part factory workers in welding units in Thailand.

    Science.gov (United States)

    Sriopas, Apiradee; Chapman, Robert S; Sutammasa, Saravudh; Siriwong, Wattasit

    2017-01-24

    Most workers in auto part factories in Thailand are usually exposed to excessive noise in their workplace. This study aimed to assess the level of occupational noise-induced hearing loss and investigate risk factors causing hearing loss in auto part factory workers in the welding units in Thailand. This was a cross-sectional study. One hundred eighty subjects were recruited from 356 workers in the welding unit of three factories. Sixty eligible subjects in each factory were selected by systemic random sampling. The subjects were interviewed using a face-to-face questionnaire. Noise exposure levels and audiograms were measured by a noise dosimeter and an audiometer, respectively. The findings confirmed that noise exposure levels of 86-90 dB (A) and exceeding 90 dB (A) significantly increased the risk of hearing loss in either ear. A noise exposure level exceeding 90 dB (A) significantly increased the prevalence of hearing loss in both ears. Regarding, a 10-pack-year smoking history increased the prevalence of hearing loss in either ear or both ears. In addition, subjects with employment duration exceeding 10 years significantly developed hearing loss in either ear. The engineering control or personal control by wearing hearing protection device should be used to decrease noise exposure levels lower than 85 dB (A) for 8 h. Moreover, if the exposure level reaches 85 dB (A) for 8 h, the employer needs to implement a hearing conservation program in the workplace.

  9. Prevention of noise-induced hearing loss in the Canadian military.

    Science.gov (United States)

    Pelausa, E O; Abel, S M; Simard, J; Dempsey, I

    1995-10-01

    A prospective study was undertaken to investigate the development of noise-induced hearing loss in Canadian military recruits, and to assess the effectiveness of the hearing conservation program currently in place. The participants were 134 men and women, 20 to 30 years of age, employed in four trades, three of these (infantry, artillery, and armour) associated with high noise levels. The data comprised audiometric measurements made at the time of entry and after 3 years of employment, and responses to a questionnaire mainly relating to noise exposure in the workplace and during leisure activities, and the utilization of personal hearing protective devices. The findings showed that group audiograms at entry and at the 3-year recall were characterized by a 6-kHz notch that was indicative of noise-induced hearing loss, although mean threshold values were within normal limits. By the 3-year recall, 11% of the infantry had sustained a mild-to-moderate hearing loss in the left ear, greater than 25-dB HL, that was consistent with the use of small-calibre weapons. Responses to the questionnaire indicated that, while subjects appreciated the potential benefit of wearing hearing protectors, instructions in their proper use and education on the hazards of noise exposure were poor. The results suggested methods to strengthen the existing scheme for hearing conservation to further minimize risk.

  10. Medical surveillance of occupational Noise Induced Hearing Loss (NIHL) at RAPS hospital

    International Nuclear Information System (INIS)

    Manuwal, A.K.; Ganesan, S.

    2009-01-01

    Full text: One of the most challenging roles of a Certifying Surgeon is to act as catalyst for change. This paper is a presentation of the impact of such an effort. Noise is the insidious of all industrial pollutants, involving every industry and causing severe hearing loss. Exposure to excessive noise is the major avoidable cause of permanent hearing impairment. Noise - induced hearing loss (NIHL) is bilateral and symmetrical, usually affecting the higher frequencies 3 k, 4 k or 6 kHz ) and then spreading to the lower frequencies (0.5 k,1 k or 2 kHz). The major health effects are lack of concentration, irritation, fatigue, headache, sleep disturbances etc. Hearing protectors should be used when engineering controls and work practices are not feasible for reducing noise exposure to safe levels. Ear muffs, ear plugs and ear canal caps are the main types of hearing protectors. Awareness should be created among workers about the harmful effects of noise on hearing and other body systems by implementing compulsory education noise conservation programmes. The practice followed at RAPS Hospital for medical surveillance of Occupational Noise Induced Hearing Loss is being briefed

  11. [Analysis on occupational noise-induced hearing loss of different type workers in underground mining].

    Science.gov (United States)

    Liu, Q C; Duo, C H; Wang, Z; Yan, K; Zhang, J; Xiong, W; Zhu, M

    2017-11-20

    Objective: To investigate hearing loss status of blasters, drillers mechanics and so on in underground mining, and put forward suggestion diagnosis of occupational explosive deafness and occupational deafness. Methods: Underground excavation workers in a metal mine were recruited in this study, those with a history of ear disease and non-occupational deafness were all excluded. Finally, the features of pure tone audiometry of 459 noise-exposed workers were analyzed. Results: High-frequency hearing loss occurred on 351workers and the positive detection rate was 74.29%, workers who had both high-frequency and linguistic frequency hearing loss were 51 and the positive detection rate was 11.11%. The positive detection of high-frequency hearing loss in right ear (χ(2)=9.427 and P = 0.024) and in left ear (χ(2)=14.375, P =0.002) was significantly different between different exposure age groups. The positive detection of high-frequency hearing loss of driving group was the highest, followed by blasting group, mining group and machine repair group. The characteristics of the hearing loss caused by drilling noise of the blasting workers with no accident occurred were in line with that of noise-induced hearing loss. Conclusion: The diagnosis grading should be carried out according to the diagnostic criteria of occupational noise-induced deafness for the employees who engaged in the blasting operation with no record of blast accident.

  12. Defect generation and activation processes in HfO{sub 2} thin films: Contributions to stress-induced leakage currents

    Energy Technology Data Exchange (ETDEWEB)

    Oettking, Rolf; Leitsmann, Roman; Lazarevic, Florian; Plaenitz, Philipp [AQcomputare, Business Unit MATcalc, Chemnitz (Germany); Kupke, Steve; Roll, Guntrade; Slesazeck, Stefan [NaMLab gGmbH, Dresden (Germany); Nadimi, Ebrahim [AQcomputare, Business Unit MATcalc, Chemnitz (Germany); K.N. Toosi University of Technology, Faculty of Electrical Engineering, Tehran (Iran, Islamic Republic of); Trentzsch, Martin [Globalfoundries Dresden, Dresden (Germany); Mikolajick, Thomas [Technische Universitaet Dresden, Fakultaet Elektrotechnik und Informationstechnik, Institut fuer Halbleiter- und Mikrosystemtechnik, Dresden (Germany)

    2015-03-01

    An important source of degradation in thin dielectric material layers is the generation and migration of oxygen vacancies. We investigated the formation of Frenkel pairs (FPs) in HfO{sub 2} as the first structural step for the creation of new defects as well as the migration of preexisting and newly built oxygen vacancies by nudged elastic band (NEB) calculations and stress induced leakage current (SILC) experiments. The analysis indicates, that for neutral systems no stable intimate FPs are built, whereas for the charge states q = ± 2 FPs are formed at threefold and at fourfold coordinated oxygen lattice sites. Their generation and annihilation rate are in equilibrium according to the Boltzmann statistics. Distant FPs (stable defects) are unlikely to build due to high formation energies and therefore cannot be accounted for the measured gate leakage current increase of nMOSFETs under constant voltage stress. The negatively charged oxygen vacancies were found to be very immobile in contrast to positively charged V{sub 0}'s with a low migration barrier that coincides well with the experimentally obtained activation energy. We show that rather the activation of preexisting defects and migration towards the interface than the defect generation are the cause for the gate oxide degradation. (copyright 2015 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  13. Validation of Noise Induced Hearing Loss Questionnaire Among Malay Sawmill Workers in Kelantan Malaysia

    OpenAIRE

    Razman, MR; Naing, L; Aziah, D; Kamarul, IM

    2010-01-01

    Exposure to excessive noise is the major avoidable cause of permanent hearing impairment. Sawmill is one of the workplaces where workers are exposed to hazardous noise level. This study was conducted to determine the reliability and validity of noise-induced hearing loss questionnaire among sawmill workers. Materials and Methods: This cross sectional study was conducted in March 2007 among 35 consented sawmill workers. A total of 40 items; 10 items for knowledge (8 areas), 20 items for attitu...

  14. Chemical-Induced Hearing Loss in Shipyard Workers.

    Science.gov (United States)

    Schaal, Nicholas Cody; Slagley, Jeremy M; Richburg, Cynthia McCormick; Zreiqat, Majed M; Paschold, Helmut W

    2018-01-01

    The aim of this study was to determine the effect of lead, cadmium, arsenic, toluene, and xylene exposure on hearing compared with noise exposures alone. Personnel at a shipyard (n = 1266) were divided into four exposure groups on the basis of concentrations: low metals/low solvents/high noise (reference group), high metals/high solvents/low noise, high metals/low solvents/high noise, and high metals/high solvents/high noise. Hearing changes occurring from the years 2004 to 2015 were analyzed. Hearing changes were significantly worse at 1000 Hz (P = 0.007), averaged across 2000 to 4000 Hz (P = 0.014), and averaged across 500 to 6000 Hz (P = 0.014) for the high metals/high solvent/high noise group compared with the low metals/low solvents/high noise only reference group. Simultaneous exposures classified as high for metals/solvents/noise appear to damage hearing more than exposure to noise alone. Hearing conservation programs should take into consideration combined exposures to metals, solvents, and noise, not simply exposure to noise.

  15. Interventions to prevent occupational noise-induced hearing loss.

    Science.gov (United States)

    Tikka, Christina; Verbeek, Jos H; Kateman, Erik; Morata, Thais C; Dreschler, Wouter A; Ferrite, Silvia

    2017-07-07

    This is the second update of a Cochrane Review originally published in 2009. Millions of workers worldwide are exposed to noise levels that increase their risk of hearing disorders. There is uncertainty about the effectiveness of hearing loss prevention interventions. To assess the effectiveness of non-pharmaceutical interventions for preventing occupational noise exposure or occupational hearing loss compared to no intervention or alternative interventions. We searched the CENTRAL; PubMed; Embase; CINAHL; Web of Science; BIOSIS Previews; Cambridge Scientific Abstracts; and OSH UPDATE to 3 October 2016. We included randomised controlled trials (RCT), controlled before-after studies (CBA) and interrupted time-series (ITS) of non-clinical interventions under field conditions among workers to prevent or reduce noise exposure and hearing loss. We also collected uncontrolled case studies of engineering controls about the effect on noise exposure. Two authors independently assessed study eligibility and risk of bias and extracted data. We categorised interventions as engineering controls, administrative controls, personal hearing protection devices, and hearing surveillance. We included 29 studies. One study evaluated legislation to reduce noise exposure in a 12-year time-series analysis but there were no controlled studies on engineering controls for noise exposure. Eleven studies with 3725 participants evaluated effects of personal hearing protection devices and 17 studies with 84,028 participants evaluated effects of hearing loss prevention programmes (HLPPs). Effects on noise exposure Engineering interventions following legislationOne ITS study found that new legislation in the mining industry reduced the median personal noise exposure dose in underground coal mining by 27.7 percentage points (95% confidence interval (CI) -36.1 to -19.3 percentage points) immediately after the implementation of stricter legislation. This roughly translates to a 4.5 dB(A) decrease in

  16. Predictive factors of occupational noise-induced hearing loss in Spanish workers: A prospective study.

    Science.gov (United States)

    Pelegrin, Armando Carballo; Canuet, Leonides; Rodríguez, Ángeles Arias; Morales, Maria Pilar Arévalo

    2015-01-01

    The purpose of our study was to identify the main factors associated with objective noise-induced hearing loss (NIHL), as indicated by abnormal audiometric testing, in Spanish workers exposed to occupational noise in the construction industry. We carried out a prospective study in Tenerife, Spain, using 150 employees exposed to occupational noise and 150 age-matched controls who were not working in noisy environments. The variables analyzed included sociodemographic data, noise-related factors, types of hearing protection, self-report hearing loss, and auditory-related symptoms (e.g., tinnitus, vertigo). Workers with pathological audiograms had significantly longer noise-exposure duration (16.2 ± 11.4 years) relative to those with normal audiograms (10.2 ± 7.0 years; t = 3.99, P hearing protection measures had audiometric abnormalities (94.1%). Additionally, workers using at least one of the protection devices (earplugs or earmuffs) had significantly more audiometric abnormalities than those using both protection measures simultaneously (Chi square = 16.07; P hearing protection measures [odds ratio (OR) = 12.30, confidence interval (CI) = 4.36-13.81, P hearing protection measures, in particular earplugs and earmuffs, associates with a lower rate of audiometric abnormalities in subjects with high occupational noise exposure. The use of hearing protection measures at work and noise-exposure duration are best predictive factors of NIHL. Auditory-related symptoms and self-report hearing loss do not represent good indicators of objective NIHL. Routine monitoring of noise levels and hearing status are of great importance as part of effective hearing conservation programs.

  17. Age, duration of work, noise and vibration in inducing hearing and balance impairments

    Directory of Open Access Journals (Sweden)

    Jenny Bashiruddin

    2005-06-01

    Full Text Available Noisy and vibrating bajaj, a public transportation in Jakarta, is a potential risk in inducing hearing and balance problems. Bajaj drivers in the Jakarta area were chosen by consecutive sampling and examined medically in the Neurotological Subdivision of the ENT Department of the Cipto Mangunkusumo Hospital, Jakarta. Hearing and balance impairments were then diagnosed from audiometric and posturographic tests. The study was carried out from March 2000 until October 2001. A number of 350 bajaj drivers participated in this study. There were 97 subjects without hearing and balance impairments, and 96 subjects suffered from hearing and balance impairments. Compared to drivers aged less than 40 years, those aged 41 years or more had a four-fold increased risk of developing hearing and balance impairments [adjusted odds ratio (OR = 3.90; 95% confidence interval (CI = 1.67-9.01. Drivers working 9 hours or more a day had an increased risk 2.3 times of developing hearing and balance impairments compared those working less than 9 hours a day (adjusted OR = 2.32; 95% CI=I.22-4.41. Furthermore, when compared to those who had been working for 1-5 years, those who had been working for 5 years had an increased tendency of developing hearing and balance impairments. Those who had been working 21-30 years had a seven-fold increased risk of developing hearing and balance impairments (adjusted OR = 7.11; 95% CI = 1.88-26.92. To minimize hearing and balance impairments bajaj drivers are recommended to work less than 8 hours a day. (Med J Indones 2005; 14: 101-6Keywords: noise, vibration, hearing, balance impairments, driver

  18. Experimental investigation of localized stress-induced leakage current distribution in gate dielectrics using array test circuit

    Science.gov (United States)

    Park, Hyeonwoo; Teramoto, Akinobu; Kuroda, Rihito; Suwa, Tomoyuki; Sugawa, Shigetoshi

    2018-04-01

    Localized stress-induced leakage current (SILC) has become a major problem in the reliability of flash memories. To reduce it, clarifying the SILC mechanism is important, and statistical measurement and analysis have to be carried out. In this study, we applied an array test circuit that can measure the SILC distribution of more than 80,000 nMOSFETs with various gate areas at a high speed (within 80 s) and a high accuracy (on the 10-17 A current order). The results clarified that the distributions of localized SILC in different gate areas follow a universal distribution assuming the same SILC defect density distribution per unit area, and the current of localized SILC defects does not scale down with the gate area. Moreover, the distribution of SILC defect density and its dependence on the oxide field for measurement (E OX-Measure) were experimentally determined for fabricated devices.

  19. Noise-induced hearing loss in small-scale metal industry in Nepal.

    Science.gov (United States)

    Whittaker, J D; Robinson, T; Acharya, A; Singh, D; Smith, M

    2014-10-01

    There has been no previous research to demonstrate the risk of noise-induced hearing loss in industry in Nepal. Limited research on occupational noise-induced hearing loss has been conducted within small-scale industry worldwide, despite it being a substantial and growing cause of deafness in the developing world. The study involved a cross-sectional audiometric assessment, with questionnaire-based examinations of noise and occupational history, and workplace noise level assessment. A total of 115 metal workers and 123 hotel workers (control subjects) were recruited. Noise-induced hearing loss prevalence was 30.4 per cent in metal workers and 4.1 per cent in hotel workers, with a significant odds ratio of 10.3. Except for age and time in occupation, none of the demographic factors were significant in predicting outcomes in regression analyses. When adjusted for this finding, and previous noise-exposed occupations, the odds ratio was 13.8. Workplace noise was significantly different between the groups, ranging from 65.3 to 84.7 dBA in metal worker sites, and from 51.4 to 68.6 dBA in the control sites. Metal workers appear to have a greater risk of noise-induced hearing loss than controls. Additional research on occupational noise-induced hearing loss in Nepal and small-scale industry globally is needed.

  20. Evaluation of the risk of noise-induced hearing loss among unscreened male industrial workers

    Science.gov (United States)

    Prince, Mary M.; Gilbert, Stephen J.; Smith, Randall J.; Stayner, Leslie T.

    2003-02-01

    Variability in background risk and distribution of various risk factors for hearing loss may explain some of the diversity in excess risk of noise-induced hearing loss (NIHL). This paper examines the impact of various risk factors on excess risk estimates of NIHL using data from the 1968-1972 NIOSH Occupational Noise and Hearing Survey (ONHS). Previous analyses of a subset of these data focused on 1172 highly ``screened'' workers. In the current analysis, an additional 894 white males (609 noise-exposed and 285 controls), who were excluded for various reasons (i.e., nonoccupational noise exposure, otologic or medical conditions affecting hearing, prior occupational noise exposure) have been added (n=2066) to assess excess risk of noise-induced material impairment in an unscreened population. Data are analyzed by age, duration of exposure, and sound level (8-h TWA) for four different definitions of noise-induced hearing impairment, defined as the binaural pure-tone average (PTA) hearing threshold level greater than 25 dB for the following frequencies: (a) 1-4 kHz (PTA1234), (b) 1-3 kHz (PTA123), (c) 0.5, 1, and 2 kHz (PTA512), and (d) 3, 4, and 6 kHz (PTA346). Results indicate that populations with higher background risks of hearing loss may show lower excess risks attributable to noise relative to highly screened populations. Estimates of lifetime excess risk of hearing impairment were found to be significantly different between screened and unscreened population for noise levels greater than 90 dBA. Predicted age-related risk of material hearing impairment in the ONHS unscreened population was similar to that predicted from Annex B and C of ANSI S3.44 for ages less than 60 years. Results underscore the importance of understanding differential risk patterns for hearing loss and the use of appropriate reference (control) populations when evaluating risk of noise-induced hearing impairment among contemporary industrial populations.

  1. Use of Otoacoustic emissions in noise induced hearing loss prevention

    CSIR Research Space (South Africa)

    Edwards, A

    2010-10-01

    Full Text Available in laboratory- main clinical use on identification of hearing loss in newborn babies • Clinically sensitive tool for assessing NIHL and the outer hair cells (OHC) • repeatable results • identify cochlear damage before evidenced on an audiogram – normal... audiogram but evidence of OHC loss • Feasible method of evaluating HPD effectiveness using temporary emission shift (TES) • CSIR research developed a prediction model for Hearing Threshold Levels Copy of dancing hair cell.wm © CSIR 2010 Slide 6...

  2. Noise-induced hearing loss in construction workers being assessed for hand-arm vibration syndrome.

    Science.gov (United States)

    House, Ronald A; Sauvé, John T; Jiang, Depeng

    2010-01-01

    Construction workers are at risk of noise-induced hearing loss (NIHL) but often have no periodic audiometric testing. The participants were construction workers assessed for Hand-Arm Vibration Syndrome (HAVS) at the Occupational Health Clinic, St. Michael's Hospital, Toronto, Ontario. Audiometry was offered and 169 of the 191 workers assessed for HAVS agreed to have the audiometric test. The objective was to examine the prevalence of hearing loss in these 169 workers and to determine the effect on hearing of duration of work in construction (as a proxy for noise exposure) and the severity of vibration white finger (VWF) which previous studies have suggested is a marker for increased individual susceptibility for NIHL. VWF was measured by the Stockholm vascular scale. All participants were men, median age of 57 (range: 28-75), median number of years worked in construction of 35 (range: 4-52). All of the Spearman rank correlations between years worked in construction and the hearing levels at each audiometric frequency were statistically significant (p hearing loss at or above the level at which a workers' compensation pension would be granted in Ontario and the prevalence of this auditory outcome had a statistically significant increase as years worked in construction increased. Multivariate linear regression indicated that VWF also had a statistically significant effect on hearing loss for all audiometric frequencies combined after controlling for years worked in construction. Improved prevention of hearing loss in construction workers is needed.

  3. Risk of hearing loss among workers with vibration-induced white fingers.

    Science.gov (United States)

    Pettersson, Hans; Burström, Lage; Hagberg, Mats; Lundström, Ronnie; Nilsson, Tohr

    2014-12-01

    We examined the risk of hearing loss for workers who use hand-held vibrating tools with vibration-induced white fingers (VWF) compared to workers without VWF. Data on 184 participants from a 21-year cohort were gathered with questionnaires and measurements. The effects on hearing status of VWF, hand-arm vibration exposure, smoking habits, age and two-way interactions of these independent variables were examined with binary logistic regression. Analyses were made for the right hand and ear as well as for the hand with VWF and the ear with worse categorized hearing status. Workers with VWF in their right hand had an increased risk of hearing loss (odds ratio 2.2-2.3) in the right ear. Workers with VWF in any hand did not have any increased risk of hearing loss in the ear with worse hearing status. This study supports the hypothesis that VWF increases the risk of hearing loss among workers who use hand-held vibrating tools in a noisy environment. © 2014 Wiley Periodicals, Inc.

  4. Chloramphenicol Induced Hearing Loss | Ogisi | Nigerian Journal of ...

    African Journals Online (AJOL)

    Background: With the widespread use of the drug Chloramphenicol in treatment of typhoid fever, a number of cases of deafness are coming to light following such ... tragedy by limiting the use of this drug is stressed. (Nig J Surg Res 2001; 3: 75 – 80) KEY WORDS: Hearing Loss, Chloramphenicol, Typhoid Fever, Handicap ...

  5. Transforming growth factor β1 inhibition protects from noise-induced hearing loss

    Directory of Open Access Journals (Sweden)

    Silvia eMurillo-Cuesta

    2015-03-01

    Full Text Available Excessive exposure to noise damages the principal cochlear structures leading to hearing impairment. Inflammatory and immune responses are central mechanisms in cochlear defensive response to noise but, if unregulated, they contribute to inner ear damage and hearing loss. Transforming growth factor ß (TGF-ß is a key regulator of both responses and high levels of this factor have been associated with cochlear injury in hearing loss animal models. To evaluate the potential of targeting TGF-ß as a therapeutic strategy for preventing or ameliorating noise-induced hearing loss, we studied the auditory function, cochlear morphology, gene expression and oxidative stress markers in mice exposed to noise and treated with TGF-ß1 peptidic inhibitors P17 and P144, just before or immediately after noise insult. Our results indicate that systemic administration of both peptides significantly improved both the evolution of hearing thresholds and the degenerative changes induced by noise-exposure in lateral wall structures. Moreover, treatments ameliorated the inflammatory state and redox balance. These therapeutic effects were dose-dependent and more effective if the TGF-ß1 inhibitors were administered prior to inducing the injury. In conclusion, inhibition of TGF-ß1 actions with antagonistic peptides represents a new, promising therapeutic strategy for the prevention and repair of noise-induced cochlear damage.

  6. Evaluation of changes in serum chemistry in association with feed withdrawal or high dose oral gavage with Dextran Sodium Sulfate (DSS) induced gut leakage in broiler chickens

    Science.gov (United States)

    Dextran sodium sulfate (DSS) has been shown to be effective at inducing enteric inflammation in broiler chickens, resulting in increased leakage of orally administered fluorescein isothiocyanate dextran to circulation. In a previous study, two doses of DSS (0.45g/dose) administered as oral gavage re...

  7. Swept-sine noise-induced damage as a hearing loss model for preclinical assays

    Directory of Open Access Journals (Sweden)

    Lorena eSanz

    2015-02-01

    Full Text Available Mouse models are key tools for studying cochlear alterations in noise-induced hearing loss and for evaluating new therapies. Stimuli used to induce deafness in mice are usually white and octave band noises that include very low frequencies, considering the large mouse auditory range. We designed different sound stimuli, enriched in frequencies up to 20 kHz (violet noises to examine their impact on hearing thresholds and cochlear cytoarchitecture after short exposure. In addition, we developed a cytocochleogram to quantitatively assess the ensuing structural degeneration and its functional correlation. Finally, we used this mouse model and cochleogram procedure to evaluate the potential therapeutic effect of transforming growth factor β1 inhibitors P17 and P144 on noise-induced hearing loss. CBA mice were exposed to violet swept-sine noise with different frequency ranges (2-20 or 9-13 kHz and levels (105 or 120 dB SPL for 30 minutes. Mice were evaluated by auditory brainstem response and otoacoustic emission tests prior to and 2, 14 and 28 days after noise exposure. Cochlear pathology was assessed with gross histology; hair cell number was estimated by a stereological counting method. Our results indicate that functional and morphological changes induced by violet swept-sine noise depend on the sound level and frequency composition. Partial hearing recovery followed the exposure to 105 dB SPL, whereas permanent cochlear damage resulted from the exposure to 120 dB SPL. Exposure to 9-13 kHz noise caused an auditory threshold shift in those frequencies that correlated with hair cell loss in the corresponding areas of the cochlea that were spotted on the cytocochleogram. In summary, we present mouse models of noise-induced hearing loss, which depending on the sound properties of the noise, cause different degrees of cochlear damage, and could therefore be used to study molecules which are potential players in hearing loss protection and repair.

  8. Using the extended parallel process model to prevent noise-induced hearing loss among coal miners in Appalachia

    Energy Technology Data Exchange (ETDEWEB)

    Murray-Johnson, L.; Witte, K.; Patel, D.; Orrego, V.; Zuckerman, C.; Maxfield, A.M.; Thimons, E.D. [Ohio State University, Columbus, OH (US)

    2004-12-15

    Occupational noise-induced hearing loss is the second most self-reported occupational illness or injury in the United States. Among coal miners, more than 90% of the population reports a hearing deficit by age 55. In this formative evaluation, focus groups were conducted with coal miners in Appalachia to ascertain whether miners perceive hearing loss as a major health risk and if so, what would motivate the consistent wearing of hearing protection devices (HPDs). The theoretical framework of the Extended Parallel Process Model was used to identify the miners' knowledge, attitudes, beliefs, and current behaviors regarding hearing protection. Focus group participants had strong perceived severity and varying levels of perceived susceptibility to hearing loss. Various barriers significantly reduced the self-efficacy and the response efficacy of using hearing protection.

  9. Catheter-Malposition-Induced Cardiac Tamponade via Contrast Media Leakage During Computed Tomography Study

    International Nuclear Information System (INIS)

    Liang, C.-D.; Ko, S.-F.; Huang, C.-F.; Chien, S.J.; Tiao, M.M.

    2005-01-01

    We present a rare case of a central venous catheter-malposition-induced life-threatening cardiac tamponade as a result of computed tomography (CT) with contrast enhancement in an infant with a ventricular septal defect and pulmonary atresia after a modified Blalock-Taussig shunt. The diagnosis was confirmed by chest radiographs and CT study with catheter perforation through the right atrial wall and extravasation of the contrast medium into the pericardium, leading to cardiac tamponade and subsequent circulatory collapse. Two hours after successful cardiopulmonary resuscitation, the patient gradually resumed normal hemodynamic status

  10. Noise.Induced Hearing Loss Still a Problem in Shipbuilders: A Cross ...

    African Journals Online (AJOL)

    Background: Workplace safety regulations seek to mitigate noise.induced hearing loss (NIHL), conventionally associated with the shipbuilding industry. Despite this, are workers still predisposed to NIHL? Aims: To study the prevalence of NIHL among noise.exposed subjects in the shipbuilding industry in Goa and to ...

  11. Effects of noise-induced hearing loss within Port Harcourt metropolis ...

    African Journals Online (AJOL)

    This paper investigates the effects of Noise-Induced Hearing Loss within Port Harcourt Metropolis using a micro-controlled diagnostic audiometer (Kamplex KLD21).The data was obtained at two specific locations namely: Rivers State University of Science and Technology and Port Harcourt International Airport.

  12. Prevention of adolescents' music-induced hearing loss due to discotheque attendance: a Delphi study

    NARCIS (Netherlands)

    Vogel, I.; Brug, J.; Ploeg, van der C.P.B.; Raat, H.

    2009-01-01

    Noise-induced hearing loss is a significant social and public health problem, which is found in increasing numbers of adolescents. Young people are particularly likely to expose themselves to potentially damaging loud sounds during leisure activities. Visiting discotheques is one of the most popular

  13. Hemolysis-induced Lung Vascular Leakage Contributes to the Development of Pulmonary Hypertension.

    Science.gov (United States)

    Rafikova, Olga; Williams, Elissa R; McBride, Matthew L; Zemskova, Marina; Srivastava, Anup; Nair, Vineet; Desai, Ankit A; Langlais, Paul R; Zemskov, Evgeny; Simon, Marc; Mandarino, Lawrence J; Rafikov, Ruslan

    2018-04-13

    While hemolytic anemia-associated pulmonary hypertension (PH) and pulmonary arterial hypertension (PAH) are more common than the prevalence of idiopathic PAH alone, the role of hemolysis in the development of PAH is poorly characterized. We hypothesized that hemolysis independently contributes to PAH pathogenesis via endothelial barrier dysfunction with resulting perivascular edema and inflammation. Plasma samples from patients with and without PAH (both confirmed by right heart catheterization) were used to measure free hemoglobin (Hb) and its correlation with PAH severity. A sugen(50mg/kg)/hypoxia(3wks)/normoxia(2wks) rat model was used to elucidate the role of free Hb/heme pathways in PAH. Human lung microvascular endothelial cells (HLMVECs) were utilized to study heme-mediated endothelial barrier effects. Our data indicate that PAH patients have increased levels of free Hb in plasma that correlate with PAH severity. There is also a significant accumulation of free Hb and depletion of haptoglobin in the rat model. In rats, perivascular edema was observed at early time points concomitant with increased infiltration of inflammatory cells. Heme-induced endothelial permeability in HLMVECs involved activation of the p38/HSP27 pathway. Indeed, the rat model also exhibited increased activation of p38/HSP27 during the initial phase of PH. Surprisingly, despite the increased levels of hemolysis and heme-mediated signaling, there was no heme oxygenase-1 activation. This can be explained by observed destabilization of HIF1a during the first two weeks of PH regardless of hypoxic conditions. Our data suggest that hemolysis may play a significant role in PAH pathobiology.

  14. The Physiological Bases of Hidden Noise-Induced Hearing Loss: Protocol for a Functional Neuroimaging Study.

    Science.gov (United States)

    Dewey, Rebecca Susan; Hall, Deborah A; Guest, Hannah; Prendergast, Garreth; Plack, Christopher J; Francis, Susan T

    2018-03-09

    procedures for hidden hearing loss, enabling early identification of noise-induced auditory damage via the detection of changes in central auditory processing. Consequently, this will generate the opportunity to give personalized advice regarding provision of ear defense and monitoring of further damage, thus reducing the incidence of noise-induced hearing loss. ©Rebecca Susan Dewey, Deborah A Hall, Hannah Guest, Garreth Prendergast, Christopher J Plack, Susan T Francis. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 09.03.2018.

  15. Evidence of noise-induced hearing loss in young people studying popular music.

    Science.gov (United States)

    Barlow, Christopher

    2011-06-01

    The number of students studying popular music, music technology, and sound engineering courses at both school and university to has increased rapidly in the last few years. These students are generally involved in music-making/recording and listening to a high level, usually in environments with amplified music. Recent studies have shown that these students are potentially exposed to a high risk of noise-induced hearing loss (NIHL( and are not covered by the same regulatory framework as employees. This study examined the pure tone air conduction hearing thresholds of 50 undergraduate students, including recent school leavers, on a range of popular music courses, to assess if there was evidence of hearing loss. Forty-four percent of students showed evidence of audiometric notch at 4-6 kHz, and 16% were classified under the UK Occupational Health and Safety guidelines as exhibiting mild hearing loss. Instance of audiometric notch was considerably higher than reported from studies of the general population but was around the same level or lower than that reported from studies of "traditional" music courses and conservatoires, suggesting no higher risk for popular music students than for "classical" music students. No relationship with age was present, suggesting that younger students were as likely to exhibit audiometric notch as mature students. This indicates that these students may be damaging their hearing through leisure activities while still at school, suggesting a need for robust education measures to focus on noise exposure of young people.

  16. The worker's ear: a history of noise-induced hearing loss.

    Science.gov (United States)

    Thurston, Floyd E

    2013-03-01

    Hearing loss afflicts millions of people throughout the world, and many of those millions are workers who have been exposed to excessive noise. People have always been surrounded by a variety of sounds in their environments, but the invention of gunpowder and the Industrial Revolution introduced new sounds of greater intensity than ever before. It is only within the past 40 years that serious efforts to reduce excessive noise at work sites have been initiated. In the latter half of the 20th century, many governments imposed regulations to limit workers' exposure to loud sounds. Because of this recent action, some people may believe that the recognition of occupational noise-induced hearing loss (NIHL) is relatively new. However, a review of selected historical and medical manuscripts, books, and articles show that the association of hearing changes with loud noise exposure was recognized for centuries before systematic attempts were made to limit the exposure. Delays in implementing controls to limit noise exposure were due to cultural reasons, technical problems in controlling noise generation, and a lack of understanding of the mechanics of hearing loss. A historical perspective on this issue may remind health care providers that they need to continue to emphasize hearing conservation measures as occupational noise exposures change with the shift of industrial activities between countries. Copyright © 2012 Wiley Periodicals, Inc.

  17. Hearing loss induced by loud music among musicians of symphonic orchestra

    Directory of Open Access Journals (Sweden)

    Tanja Carli

    2012-12-01

    Full Text Available Noise-induced hearing loss is an important public health issue, especially among musicians who are, more than any other occupation, dependent on their hearing. For them, hearing impairment is due to too loud music, the effect of which, if exceeding the limit depending on the individual sensitivity of one’s ear, can be compared with theeffect of noise on the ear. Risk factors for its development are: the type of musical instrument and sound character, the way of playing, music genre or composition, duration of exposure to loud music, sound source and its distance from the ear, intervals of acoustic stimuli, individual factors and the musician’s position in the orchestra. Hearing impairment is greater at higher frequencies; in pure tone audiogram it is shown as notches between 3000 and 6000 Hz and is most frequent in the wind and brass section. Hearing loss is greater among violinists and typically affects the left ear owing to the sound source proximity and their position in the orchestra. The most common health problems take the form of diplacusis, algiacusis and tinnitus, as exposure to the loud acoustic stimulus above 90 dB(A cause damage to the inner ear, the so-called acoustic trauma. Use of personal protective equipment among musicians is low especially because of too much high-frequency attenuation and occlusion effect.

  18. A study on the annular leakage-flow-induced vibrations. 1st report. Stability for translational and rotational single-degree-of-freedom systems

    International Nuclear Information System (INIS)

    Li, Dong-Wei; Kaneko, Shigehiko; Hayama, Shinji

    1999-01-01

    This study reports the stability of annular leakage-flow-induced vibrations. The pressure distribution of fluid between a fixed outer cylinder and a vibrating inner cylinder was obtained in the case of a translationally and rotationally coupled motion of the inner cylinder. The unsteady fluid force acting on the inner cylinder in the case of translational and rotational single-degree-of-freedom vibrations was then expressed in terms proportional to the acceleration, velocity, and displacement. Then the critical flow rate (at which stability was lost) was determined for an annular leakage-flow-induced vibration. Finally, the stability was investigated theoretically. It is known that instability will occur in the case of a divergent passage, but the critical flow rate depends on the passage increment in a limited range: the eccentricity of the passage and the pressure loss factor at the inlet of the passage lower the stability. (author)

  19. Murine CMV-induced hearing loss is associated with inner ear inflammation and loss of spiral ganglia neurons.

    Directory of Open Access Journals (Sweden)

    Russell D Bradford

    2015-04-01

    Full Text Available Congenital human cytomegalovirus (HCMV occurs in 0.5-1% of live births and approximately 10% of infected infants develop hearing loss. The mechanism(s of hearing loss remain unknown. We developed a murine model of CMV induced hearing loss in which murine cytomegalovirus (MCMV infection of newborn mice leads to hematogenous spread of virus to the inner ear, induction of inflammatory responses, and hearing loss. Characteristics of the hearing loss described in infants with congenital HCMV infection were observed including, delayed onset, progressive hearing loss, and unilateral hearing loss in this model and, these characteristics were viral inoculum dependent. Viral antigens were present in the inner ear as were CD(3+ mononuclear cells in the spiral ganglion and stria vascularis. Spiral ganglion neuron density was decreased after infection, thus providing a mechanism for hearing loss. The lack of significant inner ear histopathology and persistence of inflammation in cochlea of mice with hearing loss raised the possibility that inflammation was a major component of the mechanism(s of hearing loss in MCMV infected mice.

  20. Could driving safety be compromised by noise exposure at work and noise-induced hearing loss?

    Science.gov (United States)

    Picard, Michel; Girard, Serge André; Courteau, Marilène; Leroux, Tony; Larocque, Richard; Turcotte, Fernand; Lavoie, Michel; Simard, Marc

    2008-10-01

    A study was conducted to verify if there is an association between occupational noise exposure, noise-induced hearing loss and driving safety expanding on previous findings by Picard, et al. (2008) that the two factors did increase accident risk in the workplace. This study was made possible when driving records of all Quebec drivers were made available by the Societe de l'assurance automobile du Quebec (SAAQ is the state monopoly responsible for the provision of motor vehicle insurance and the compensation of victims of traffic accidents). These records were linked with personal records maintained by the Quebec National Institute of Public Health as part of its mission to prevent noise induced hearing loss in the workplace. Individualized information on occupational noise exposure and hearing sensitivity was available for 46,030 male workers employed in noisy industries who also held a valid driver's permit. The observation period is of five years duration, starting with the most recent audiometric examination. The associations between occupational noise exposure levels, hearing status, and personal driving record were examined by log-binomial regression on data adjusted for age and duration of exposure. Daily noise exposures and bilateral average hearing threshold levels at 3, 4, and 6 kHz were used as independent variables while the dependent variables were 1) the number of motor vehicle accidents experienced by participants during the study period and 2) participants' records of registered traffic violations of the highway safety code. The findings are reported as prevalence ratios (PRs) with their 95% confidence intervals (CIs). Attributable numbers of events were computed with the relevant PRs, lesser-noise, exposed workers and those with normal hearing levels making the group of reference. Adjusting for age confirmed that experienced workers had fewer traffic accidents. The data show that occupational noise exposure and hearing loss have the same effect on

  1. Deterioration of noise-induced hearing loss among bottling factory workers.

    Science.gov (United States)

    Ologe, F E; Olajide, T G; Nwawolo, C C; Oyejola, B A

    2008-08-01

    monitoring hearing deterioration. It is necessary to enforce existing occupational health laws in our industries in order to prevent noise-induced hearing loss, since it is eminently preventable.

  2. Combination therapy using antioxidants and low level laser therapy (LLLT) on noise induced hearing loss (NIHL)

    Science.gov (United States)

    Chang, So-Young; Lim, Sung Kyu; Lee, Min young; Chung, Phil-Sang; Jung, Jae-Yun; Rhee, Chung-Ku

    2016-02-01

    One of the most common factors that cause hearing disorders is noise trauma. Noise is an increasing hazard and it is pervasive, which makes it difficult to take precautions and prevent noise-induced hearing loss (NIHL). The prevalence of hearing loss among factory workers to be 42 %[1]. Ocupational noise induced hearing loss (ONIHL) continues to be a significant occupational hazard. ONIHL is permanent and may cause significant disability, for which there currently exists no cure, but is largely preventable. More than 30 million Americans are potentially exposed to hazardous noise levels in occupations such as transportation, construction, and coal mining, as well as recreationally. In the mainstream setting, exposure avoidance strategies aimed to reduce the incidence of ONIHL remain the focus of public health and occupational medicine approaches[2]. In military conditions this is most often caused by such things as explosions, blasts, or loud noises from vehicles ranging from 100 to 140 dB[3] and military weapons generating approximately 140-185 dB peak sound pressure levels[4].

  3. The Effect of the Cholesterol Levels on Noise-Induced Hearing Loss.

    Science.gov (United States)

    Demir, Mehmet Gokhan; Aydin, Sedat

    2018-01-01

    Introduction  Noise-induced hearing loss (NIHL), which is one of the most common occupational diseases among industrialized populations, is associated with longstanding exposure to high levels of noise. The pathogenesis of NIHL is not clear, but some genes and their activity at the tissue level have been investigated. Hypercholesterolemia, which can disturb the microcirculation, can be one of the underlying pathologies in hearing loss. Objective  To investigate the relationship between NIHL and hypercholesterolemia. Methods  The study group was selected among workers who had an occupational exposure of 85 dB of noise for at least 10 years. The audiologic assessment was recorded at seven frequencies (500 Hz, 1,000 Hz, 2,000 Hz, 3,000 Hz, 4,000 Hz, 6,000 Hz and 8,000 Hz). A total of 456 workers were included in the study and divided into two groups: the control group (252 patients) and the NIHL group (204 patients). After the audiologic measurement, blood samples were taken and investigated for blood cholesterol levels. According to these results, the groups were compared. Results  Both groups were similarly distributed regarding age and occupational exposure time ( p  > 0.05). We could not detect any association between cholesterol levels and noise-induced hearing loss ( p   0.05). Conclusion  Noise-induced hearing loss is still a common occupational problem that can be prevented by hearing conservation programs and occupational health and safety training. Still, we know little about the relationship between NIHL and hypercholesterolemia. According to our findings, we cannot detect any relationship. Controlled studies and studies with human individuals can be made possible in the future with diagnostic innovations in tissue imaging and tissue microcircular sampling.

  4. Renexin as a rescue regimen for noise-induced hearing loss

    Directory of Open Access Journals (Sweden)

    So Young Park

    2014-01-01

    Full Text Available Renexin, a compound of cilostazol and ginkgo biloba extract, has been reported to produce neuroprotective effects through antioxidant, antiplatelet, and vasodilatory mechanisms. This study was designed to investigate the protective effects of renexin on hearing, the organ of Corti (OC, and medial olivocochlear efferents against noise-induced damage. C57BL/6 mice were exposed to 110 dB SPL white noise for 60 min and then randomly divided into three groups: high- and low-dose renexin-treated groups and noise only group. Renexin were administered for 7 days: 90 mg/kg to the low-dose, and 180 mg/kg to the high-dose groups. All mice, including the controls underwent hearing tests on postnoise day 8 and were killed for cochlear harvest. We compared the hearing thresholds and morphology of the OC and cochlear efferents across the groups. The renexin-treated groups recovered from the immediate threshold shifts in a dose-dependent manner, while the noise group showed a permanent hearing loss. The renexin-treated ears demonstrated less degeneration of the OC. The diameters of the efferent terminals labeled with α-synuclein were preserved in the high-dose renexin-treated group. In the western blot assay of the cochlear homogenates, the treated groups displayed stronger expressions of α-synuclein than the noise and control groups, which may indicate that noise-induced enhanced activity of the cochlear efferent system was protected by renexin. Our results suggest that pharmacologic treatment with renexin is hopeful to reduce or prevent noise-induced hearing loss as a rescue regimen after noise exposure.

  5. Self-assessment of hearing status and risk of noise-induced hearing loss in workers in a rolling stock plant.

    Science.gov (United States)

    Pawlaczyk-Łuszczyńska, Małgorzata; Dudarewicz, Adam; Zamojska, Małgorzata; Sliwinska-Kowalska, Mariola

    2012-01-01

    Noise measurements and questionnaire inquiries were carried out for 124 workers of a rolling stock plant to develop a hearing conservation program. On the basis of that data, the risk of noise-induced hearing loss (NIHL) was evaluated. Additionally, the workers' hearing ability was assessed with the (modified) Amsterdam inventory for auditory disability and handicap, (m)AIADH. The workers had been exposed to noise at A-weighted daily noise exposure levels of 74-110 dB for 1-40 years. Almost one third of the workers complained of hearing impairment and the (m)AIADH results showed some hearing difficulties in over half of them. The estimated risk of hearing loss over 25 dB in the frequency range of 3-6 kHz was 41-50% when the standard method of predicting NIHL specified in Standard No. ISO 1999:1990 was used. This risk increased to 50-67% when noise impulsiveness, coexposure to organic solvents, elevated blood pressure and smoking were included in calculations.

  6. Leakage current-induced effects in the silicon microstrip and gas electron multiplier readout chain and their compensation method

    Science.gov (United States)

    Zubrzycka, W.; Kasinski, K.

    2018-04-01

    Leakage current flowing into the charge sensitive amplifier (CSA) is a common issue in many radiation detection systems as it can increase overall system noise, shift a DC baseline or even lead a recording channel to instability. The commonly known leakage current contributor is a detector, however other system components like wires or an input protection circuit may become a serious problem. Compensation of the leakage current resulting from the electrostatic discharge (ESD) protection circuit by properly sizing its components is possible only for a narrow temperature range. Moreover, the leakage current from external sources can be significantly larger. Many applications, especially High Energy Physics (HEP) experiments, require a fast baseline restoration for high input hit rates by applying either a low-value feedback resistor or a high feedback resistance combined with a pulsed reset circuit. Leakage current flowing in the feedback in conjunction with a large feedback resistance supplied with a pulsed reset results in a significant voltage offset between the CSA input and output which can cause problems (e.g. fake hits or instability). This paper shows an issue referred to the leakage current of the ESD protection circuit flowing into the input amplifier. The following analysis and proposed solution is a result of the time and energy readout ASIC project realization for the Compressed Baryonic Matter (CBM) experiment at FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. This chip is purposed to work with microstrip and gaseous detectors, with high average input pulses frequencies (250 kHit/s per channel) and the possibility to process input charge of both polarities. We present measurements of the test structure fabricated in UMC 180 nm technology and propose a solution addressing leakage current related issues. This work combines the leakage current compensation capabilities at the CSA level with high, controllable value of the amplifier

  7. Noise-induced hearing loss and combined noise and vibration exposure.

    Science.gov (United States)

    Turcot, A; Girard, S A; Courteau, M; Baril, J; Larocque, R

    2015-04-01

    While there is a wide body of literature addressing noise-induced hearing loss (NIHL) and hand-arm vibration syndrome (HAVS) independently, relatively few studies have considered the combined effects of noise and vibration. These studies have suggested an increased risk of NIHL in workers with vibration white finger (VWF), though the relationship remains poorly understood. To determine whether hearing impairment is worse in noise-exposed workers with VWF than in workers with similar noise exposures but without VWF. The Quebec National Institute of Public Health audiometric database was used in conjunction with work-related accident and occupational diseases data from the Quebec workers' compensation board to analyse differences in audiometry results between vibration-exposed workers in the mining and forestry industries and the overall source population, and between mining and forestry workers with documented VWF and those without VWF. The International Organization for Standardization (ISO) 7029 standards were used to calculate hearing loss not attributable to age. 15751 vibration-exposed workers were identified in an overall source population of 59339. Workers with VWF (n = 96) had significantly worse hearing at every frequency studied (500, 1000, 2000 4000 Hz) compared with other mining and forestry workers without VWF. This study confirms previous findings of greater hearing loss at higher frequencies in workers with VWF, but also found a significant difference in hearing loss at low frequencies. It therefore supports the association between combined noise and hand-arm vibration (HAV) exposure and NIHL. © The Author 2015. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Hear, Hear!

    Science.gov (United States)

    Rittner-Heir, Robbin

    2000-01-01

    Examines the problem of acoustics in school classrooms; the problems it creates for student learning, particularly for students with hearing problems; and the impediments to achieving acceptable acoustical levels for school classrooms. Acoustic guidelines are explored and some remedies for fixing sound problems are highlighted. (GR)

  9. Economic Impact of Hearing Loss and Reduction of Noise-Induced Hearing Loss in the United States.

    Science.gov (United States)

    Neitzel, Richard L; Swinburn, Tracy K; Hammer, Monica S; Eisenberg, Daniel

    2017-01-01

    Hearing loss (HL) is pervasive and debilitating, and noise-induced HL is preventable by reducing environmental noise. Lack of economic analyses of HL impacts means that prevention and treatment remain a low priority for public health and environmental investment. This article estimates the costs of HL on productivity by building on established estimates for HL prevalence and wage and employment differentials between those with and without HL. We estimate that HL affects more than 13% of the working population. Not all HL can be prevented or treated, but if the 20% of HL resulting from excessive noise exposure were prevented, the economic benefit would be substantial-we estimate a range of $58 billion to $152 billion annually, with a core estimate of $123 billion. We believe this is a conservative estimate, because consideration of additional costs of HL, including health care and special education, would likely further increase the benefits associated with HL prevention. HL is costly and warrants additional emphasis in public and environmental health programs. This study represents an important first step in valuing HL prevention-in particular, prevention of noise-induced HL-where new policies and technologies appear promising.

  10. Impact of arachidonic versus eicosapentaenoic acid on exotonin-induced lung vascular leakage: relation to 4-series versus 5-series leukotriene generation.

    Science.gov (United States)

    Grimminger, F; Wahn, H; Mayer, K; Kiss, L; Walmrath, D; Seeger, W

    1997-02-01

    Escherichia coli hemolysin (HlyA) is a proteinaceous pore-forming exotoxin that is implicated as a significant pathogenicity factor in extraintestinal E. coli infections including sepsis. In perfused rabbit lungs, subcytolytic concentrations of the toxin evoke thromboxane-mediated vasoconstriction and prostanoid-independent protracted vascular permeability increase (11). In the present study, the influence of submicromolar concentrations of free arachidonic acid (AA) and eicosapentaenoic acid (EPA) on the HlyA-induced leakage response was investigated. HlyA at concentration from 0.02 to 0.06 hemolytic units/ml provoked a dose-dependent, severalfold increase in the capillary filtration coefficient (Kfc), accompanied by the release of leukotriene(LT)B4, LTC4, and LTE4 into the recirculating buffer fluid. Simultaneous application of 100 nmol/L AA markedly augmented the HlyA-elicited leakage response, concomitant with an amplification of LTB4 release and a change in the kinetics of cysteinyl-LT generation. In contrast, 50 to 200 nmol/L EPA suppressed in a dose-dependent manner the HlyA-induced increase in Kfc values. This was accompanied by a blockage of 4-series LT generation and a dose-dependent appearance of LTB5, LTC5, and LTE5. In addition, EPA fully antagonized the AA-induced amplification of the HlyA-provoked Kfc increase, again accompanied by a shift from 4-series to 5-series LT generation. We conclude that the vascular leakage provoked by HlyA in rabbit lungs is differentially influenced by free AA versus free EPA, related to the generation of 4- versus 5-series leukotrienes. The composition of lipid emulsions used for parenteral nutrition may thus influence inflammatory capillary leakage.

  11. Model for Estimating Noise-Induced Hearing Loss Associated With Occupational Noise Exposure in a Specified US Navy Population

    National Research Council Canada - National Science Library

    Tufts, Jennifer; Weathersby, Paul K; Marshall, Lynne; Sachs, Felix

    2007-01-01

    This report details the initial steps in the development of a method for modeling the noise-induced hearing loss accrued by a population of Sailors exposed to high-level steady-state occupational noise...

  12. Strategies for the prevention of MP3-induced hearing loss among adolescents : Expert opinions from a Delphi study

    NARCIS (Netherlands)

    Vogel, I.; Brug, J.; Ploeg, C.P.B. van der; Raat, H.

    2009-01-01

    OBJECTIVE. To identify parties involved in the prevention of MP3-induced hearing loss among adolescents and potentially effective prevention strategies and interventions. METHODS. Thirty experts in fields such as scientific research, medical practice, community health professions, education, youth

  13. Epidemiology of noise-induced tinnitus and the attitudes and beliefs towards noise and hearing protection in adolescents.

    Directory of Open Access Journals (Sweden)

    Annick Gilles

    Full Text Available BACKGROUND AND OBJECTIVES: Previous research showed an increase of noise-induced symptoms in adolescents. Permanent tinnitus as a consequence of loud music exposure is usually considered as noise-induced damage. The objective was to perform an epidemiological study in order to obtain prevalence data of permanent noise-induced tinnitus as well as temporary tinnitus following noise exposure in a young population. In addition the attitudes and beliefs towards noise and hearing protection were evaluated in order to explain the use/non-use of hearing protection in a young population. METHODS: A questionnaire was completed by 3892 high school students (mean age: 16.64 years old, SD: 1.29 years. The prevalence of temporary and permanent tinnitus was assessed. In addition the 'Youth Attitudes to Noise Scale' and the 'Beliefs About Hearing Protection and Hearing Loss' were used in order to assess the attitudes and beliefs towards noise and hearing protection respectively. RESULTS: The prevalence of temporary noise-induced tinnitus and permanent tinnitus in high school students was respectively 74.9% and 18.3%. An increasing prevalence of temporary tinnitus with age was present. Most students had a 'neutral attitude' towards loud music and the use of hearing protection was minimal (4.7%. The limited use of hearing protection is explained by a logistic regression analysis showing the relations between certain parameters and the use of hearing protection. CONCLUSIONS: Despite the very high prevalence of tinnitus in such a young population, the rate of hearing protection use and the knowledge about the risks of loud music is extremely low. Future preventive campaigns should focus more on tinnitus as a warning signal for noise-induced damage and emphasize that also temporary symptoms can result in permanent noise-induced damage.

  14. On Probability Leakage

    OpenAIRE

    Briggs, William M.

    2012-01-01

    The probability leakage of model M with respect to evidence E is defined. Probability leakage is a kind of model error. It occurs when M implies that events $y$, which are impossible given E, have positive probability. Leakage does not imply model falsification. Models with probability leakage cannot be calibrated empirically. Regression models, which are ubiquitous in statistical practice, often evince probability leakage.

  15. Study and application of measures for prevention of spontaneous combustion of coal in goaf induced by air leakage

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Y.; Tang, H.; Zou, S.; Shi, S. [Xiangtan Mining Institute (China)

    1996-12-01

    To prevent spontaneous ignition of coal due to air leakage in the goaf, air stoppings were built periodically in a U-shaped air leakage area based on computer simulation and site experience. The measure had reduced remarkably the quantity and extent of air leakage in the mined-out area and expanded the extent of non-spontaneous combustion area, thus prevented effectively the risk of spontaneous ignition and gas explosion. Application of this method in Mugang Mine of Liuzhi Bureau for more than two years had reduced the economic loss by over 3 million Yuan RMB. This method is characterized by simple operation, low cost, etc. It is suitable for mines in under developed area and mines with complicated conditions which are prone to spontaneous ignition. 5 refs., 3 figs., 1 tab.

  16. Occupational noise-induced hearing loss among workers at Jomo Kenyatta International Airport, Nairobi.

    Science.gov (United States)

    Anino, J O; Afullo, A; Otieno, F

    2010-02-01

    Occupational noise induced hearing loss (NIHL) occurs among workers exposed to excessive amounts of noise for long durations. The average level of noise in some locations at Jomo Kenyatta International Airport (JKIA) was above the safe limit of 85dB hence workers were thought to be at risk. To determine the occurrence and socio demographic attributes for NIHL at JKIA. Cross sectional descriptive study. Jomo Kenyatta International Airport, Nairobi, Kenya. Mean age of respondents was 37 years with range 22 to 62, SD 8.98. Mean duration of exposure to noise was 10.7 years with range 1 to 40, SD 8.15. Prevalence of NIHL was 15.3%, with ground crew at 14.8% and air crew 16.1%. Ground crew had significantly poorer mean hearing threshold level at 3, 4 and 6 kHz than air crew (p = 0.015). Male workers were affected more than female counterparts with a male to female ratio of 4:3. 97% of those affected were non-managers, 3% managers while 68% of those affected resided in Embakasi Division close to the airport. Hearing threshold level at 4 kHz deteriorated with increasing age whereby those aged 50 years and above had a 13.7 times higher relative risk than those aged 20 to 29 years. Duration of exposure more than 10 years also had significantly higher risk (p hearing loss at 4 kHz. Occupational noise induced hearing loss occurs atJKIA and that ground crew and older workers are more vulnerable. We recommend that prevention programmes be put in place.

  17. Development of monitoring system using acoustic emission for detection of helium gas leakage for primary cooling system and flow-induced vibration for heat transfer tube of heat exchangers for the High Temperature Engineering Test Reactor (HTTR)

    International Nuclear Information System (INIS)

    Tachibana, Yukio; Kunitomi, Kazuhiko; Furusawa, Takayuki; Shinozaki, Masayuki; Satoh, Yoshiyuki; Yanagibashi, Minoru

    1998-10-01

    The High Temperature Engineering Test Reactor (HTTR) uses helium gas for its primary coolant, whose leakage inside reactor containment vessel is considered in design of the HTTR. It is necessary to detect leakage of helium gas at an early stage so that total amount of the leakage should be as small as possible. On the other hand, heat transfer tubes of heat exchangers of the HTTR are designed not to vibrate at normal operation, but the flow-induced vibration is to be monitored to provide against an emergency. Thus monitoring system of acoustic emission for detection of primary coolant leakage and vibration of heat transfer tubes was developed and applied to the HTTR. Before the application to the HTTR, leakage detection test was performed using 1/4 scaled model of outer tube of primary concentric hot gas duct. Result of the test covers detectable minimum leakage rate and effect of difference in gas, pressure, shape of leakage path and distance from the leaking point. Detectable minimum leakage rate was about 5 Ncc/sec. The monitoring system is promising in leakage detection, though countermeasure to noise is to be needed after the HTTR starts operating. (author)

  18. Characteristic of Noise-induced Hearing Loss among Workers in Construction Industries

    Science.gov (United States)

    Naadia Mazlan, Ain; Yahya, Khairulzan; Haron, Zaiton; Amsharija Mohamed, Nik; Rasib, Edrin Nazri Abdul; Jamaludin, Nizam; Darus, Nadirah

    2018-03-01

    Noise-induced hearing loss (NIHL) is among the most common occupational disease in industries. This paper investigates NIHL in construction related industries in Malaysia with particular emphasis on its relation with risk factors. The objectives of this research were to (1) quantify the prevalence of NIHL in construction related industries, and (2) assess the relationship between hearing loss and risk factors and it's characteristic. The study was conducted using 110 NIHL compensation record collected from Social Security Organisation (SOCSO), Malaysia. Risk factors namely area noise, age, temperature, smoking habit, hobby, diabetic and cardiovascular disease were identified and analysed. Results showed that there was no direct relationship between area noise with hearing impairment while there was only low relationship between age and hearing impairment. The range for area noise and age were between 70 to 140 dB(A) and 20 to 70 years, respectively. The other risk factors classified as categorical data and analysed using frequency method. Grade of impairment does not depend solely on area noise but also in combination with age and other risk factors. Characteristic of NIHL prevailed in construction related industries were presented using scatterplots and can serve as a references for future hazard control on site.

  19. Simultaneous bilateral laser therapy accelerates recovery after noise-induced hearing loss in a rat model

    Directory of Open Access Journals (Sweden)

    Jae-Hun Lee

    2016-07-01

    Full Text Available Noise-induced hearing loss is a common type of hearing loss. The effects of laser therapy have been investigated from various perspectives, including in wound healing, inflammation reduction, and nerve regeneration, as well as in hearing research. A promising feature of the laser is its capability to penetrate soft tissue; depending on the wavelength, laser energy can penetrate into the deepest part of the body without damaging non-target soft tissues. Based on this idea, we developed bilateral transtympanic laser therapy, which uses simultaneous laser irradiation in both ears, and evaluated the effects of bilateral laser therapy on cochlear damage caused by noise overexposure. Thus, the purpose of this research was to assess the benefits of simultaneous bilateral laser therapy compared with unilateral laser therapy and a control. Eighteen Sprague-Dawley rats were exposed to narrow-band noise at 115 dB SPL for 6 h. Multiple auditory brainstem responses were measured after each laser irradiation, and cochlear hair cells were counted after the 15th such irradiation. The penetration depth of the 808 nm laser was also measured after sacrifice. Approximately 5% of the laser energy reached the contralateral cochlea. Both bilateral and unilateral laser therapy decreased the hearing threshold after noise overstimulation in the rat model. The bilateral laser therapy group showed faster functional recovery at all tested frequencies compared with the unilateral laser therapy group. However, there was no difference in the endpoint ABR results or final hair cell survival, which was analyzed histologically.

  20. Stress-induced leakage current characteristics of PMOS fabricated by a new multi-deposition multi-annealing technique with full gate last process

    International Nuclear Information System (INIS)

    Wang Yanrong; Yang Hong; Xu Hao; Luo Weichun; Qi Luwei; Zhang Shuxiang; Wang Wenwu; Zhu Huilong; Zhao Chao; Chen Dapeng; Ye Tianchun; Yan Jiang

    2017-01-01

    In the process of high- k films fabrication, a novel multi deposition multi annealing (MDMA) technique is introduced to replace simple post deposition annealing. The leakage current decreases with the increase of the post deposition annealing (PDA) times. The equivalent oxide thickness (EOT) decreases when the annealing time(s) change from 1 to 2. Furthermore, the characteristics of SILC (stress-induced leakage current) for an ultra-thin SiO 2 /HfO 2 gate dielectric stack are studied systematically. The increase of the PDA time(s) from 1 to 2 can decrease the defect and defect generation rate in the HK layer. However, increasing the PDA times to 4 and 7 may introduce too much oxygen, therefore the type of oxygen vacancy changes. (paper)

  1. Leakage current suppression with a combination of planarized gate and overlap/off-set structure in metal-induced laterally crystallized polycrystalline-silicon thin-film transistors

    Science.gov (United States)

    Chae, Hee Jae; Seok, Ki Hwan; Lee, Sol Kyu; Joo, Seung Ki

    2018-04-01

    A novel inverted staggered metal-induced laterally crystallized (MILC) polycrystalline-silicon (poly-Si) thin-film transistors (TFTs) with a combination of a planarized gate and an overlap/off-set at the source-gate/drain-gate structure were fabricated and characterized. While the MILC process is advantageous for fabricating inverted staggered poly-Si TFTs, MILC TFTs reveal higher leakage current than TFTs crystallized by other processes due to their high trap density of Ni contamination. Due to this drawback, the planarized gate and overlap/off-set structure were applied to inverted staggered MILC TFTs. The proposed device shows drastic suppression of leakage current and pinning phenomenon by reducing the lateral electric field and the space-charge limited current from the gate to the drain.

  2. Dexamethasone loaded nanoparticles exert protective effects against Cisplatin-induced hearing loss by systemic administration.

    Science.gov (United States)

    Sun, Changling; Wang, Xueling; Chen, Dongye; Lin, Xin; Yu, Dehong; Wu, Hao

    2016-04-21

    Ototoxicity is one of the most important adverse effects of cisplatin chemotherapy. As a common treatment of acute sensorineural hearing loss, systemic administration of steroids was demonstrated ineffective against cisplatin-induced hearing loss (CIHL) in published studies. The current study aimed to evaluate the potential protective effect of dexamethasone (DEX) encapsulated in polyethyleneglycol-coated polylactic acid (PEG-PLA) nanoparticles (DEX-NPs) against cisplatin-induced hearing loss following systemic administration. DEX was fabricated into PEG-PLA nanoparticles using emulsion and evaporation technique as previously reported. DEX or DEX-NPs was administered intraperitoneally to guinea pigs 1h before cisplatin administration. Auditory brainstem response (ABR) threshold shifts were measured at four frequencies (4, 8, 16, and 24kHz) 1 day before and three days after cisplatin injection. Cochlear morphology was examined to evaluate inner ear injury induced by cisplatin exposure. A single dose of DEX-NPs 1h before cisplatin treatment resulted in a significant preservation of the functional and structural properties of the cochlea, which was equivalent to the effect of multidose (3 days) DEX injection. In contrast, no significant protective effect was observed by single dose injection of DEX. The results of histological examination of the cochleae were consistent with the functional measurements. In conclusion, a single dose DEX-NPs significantly attenuated cisplatin ototoxicity in guinea pigs after systemic administration at both histological and functional levels indicating the potential therapeutic benefits of these nanoparticles for enhancing the delivery of DEX in acute sensorineural hearing loss. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. Occupationally-acquired noise-induced hearing loss: a senseless workplace hazard.

    Science.gov (United States)

    Kurmis, Andrew P; Apps, Stacey A

    2007-01-01

    Occupational noise-induced hearing loss (ONIHL) describes an acquired hearing deficiency directly attributable to excessive workplace noise exposure. Data suggest that excessive noise attributes to approximately 37% of all adult causes of hearing loss and remains a significant contributor to employment-related morbidity internationally. Typically insidiously-acquired, often without frank progressive symptomatology, regional medical agencies continue to struggle with this potentially debilitating condition. The aim of the study was to provide a synopsis of the current understanding of ONIHL, its impact on individual workers and the wider international community, and to identify barriers to more uniform adoption of personal hearing protection. A review of the contemporary literature was performed using defined keyword searches and OVID, PubMed, and Google Scholar as primary electronic search engines. A number of published works were identified, describing aspects of the relationship between workplace-related noise exposure and subsequent development of employee hearing impairment, which demonstrate an overwhelming gender imbalance, with up to 97% of affected individuals being male. Industry-specific associations (e.g., mining, manufacturing and heavy construction) were well documented, as were links to toxin-specific exposures, in the recognized development of hearing loss. However, evidence of integration of appraisal of the topically-current area of genetic susceptibility was often lacking. Much discordance still exists among international agencies in the prescriptive regulation and enforcement of "safe" exposure limits. Despite a high level of public awareness regarding the importance of hearing preservation and increasingly stringent international occupational health, safety and welfare requirements mandating provision of safer work environments, ONIHL continues to be a significant occupational hazard. ONIHL is permanent and may cause significant disability, for

  4. Neuronal erythropoietin overexpression is protective against kanamycin-induced hearing loss in mice.

    Science.gov (United States)

    Bächinger, David; Horvath, Lukas; Eckhard, Andreas; Goosmann, Madeline M; Honegger, Tim; Gassmann, Max; Vogel, Johannes; Naldi, Arianne Monge

    2018-07-01

    Aminoglycosides have detrimental effects on the hair cells of the inner ear, yet these agents indisputably are one of the cornerstones in antibiotic therapy. Hence, there is a demand for strategies to prevent aminoglycoside-induced ototoxicity, which are not available today. In vitro data suggests that the pleiotropic growth factor erythropoietin (EPO) is neuroprotective against aminoglycoside-induced hair cell loss. Here, we use a mouse model with EPO-overexpression in neuronal tissue to evaluate whether EPO could also in vivo protect from aminoglycoside-induced hearing loss. Auditory brainstem response (ABR) thresholds were measured in 12-weeks-old mice before and after treatment with kanamycin for 15 days, which resulted in both C57BL/6 and EPO-transgenic animals in a high-frequency hearing loss. However, ABR threshold shifts in EPO-transgenic mice were significantly lower than in C57BL/6 mice (mean difference in ABR threshold shift 13.6 dB at 32 kHz, 95% CI 3.8-23.4 dB, p = 0.003). Correspondingly, quantification of hair cells and spiral ganglion neurons by immunofluorescence revealed that EPO-transgenic mice had a significantly lower hair cell and spiral ganglion neuron loss than C57BL/6 mice. In conclusion, neuronal overexpression of EPO is protective against aminoglycoside-induce hearing loss, which is in accordance with its known neuroprotective effects in other organs, such as the eye or the brain. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Implementation of a method to visualize noise-induced hearing loss in mass stranded cetaceans

    Science.gov (United States)

    Morell, Maria; Brownlow, Andrew; McGovern, Barry; Raverty, Stephen A.; Shadwick, Robert E.; André, Michel

    2017-02-01

    Assessment of the impact of noise over-exposure in stranded cetaceans is challenging, as the lesions that lead to hearing loss occur at the cellular level and inner ear cells are very sensitive to autolysis. Distinguishing ante-mortem pathology from post-mortem change has been a major constraint in diagnosing potential impact. Here, we outline a methodology applicable to the detection of noise-induced hearing loss in stranded cetaceans. Inner ears from two mass strandings of long-finned pilot whales in Scotland were processed for scanning electron microscopy observation. In one case, a juvenile animal, whose ears were fixed within 4 hours of death, revealed that many sensory cells at the apex of the cochlear spiral were missing. In this case, the absence of outer hair cells would be compatible with overexposure to underwater noise, affecting the region which transduces the lowest frequencies of the pilot whales hearing spectrum. Perfusion of cochlea with fixative greatly improved preservation and enabled diagnostic imaging of the organ of Corti, even 30 hours after death. This finding supports adopting a routine protocol to detect the pathological legacy of noise overexposure in mass stranded cetaceans as a key to understanding the complex processes and implications that lie behind such stranding events.

  6. Noise-induced hearing loss in a longitudinal study of Norwegian railway workers.

    Science.gov (United States)

    Lie, Arve; Skogstad, Marit; Johnsen, Torstein Seip; Engdahl, Bo; Tambs, Kristian

    2016-09-02

    The aim of this study was to analyse longitudinal data to assess the risk of noise-induced hearing loss (NIHL) in Norwegian railway workers. Longitudinal. A major Norwegian railway company. We examined data from the first and last audiograms for the period 1991-2014, from 9640 railway workers with varying occupational noise exposure and with an average observation period of 10 years. The course of hearing acuity in seven groups of railway workers (train drivers, conductors, bus drivers, traffic controllers, train maintenance workers, track maintenance workers and others) were compared with each other and with ISO standards (ISO 1999). The change in hearing threshold during the observation period was 2-3 dB in the 0.5-4 kHz range and 6-7 dB in the 3-6 kHz range adjusted for age and sex, for all occupational groups, which is slightly less than expected (8 dB) according to ISO 1999. The risk of NIHL in Norwegian railway workers during the period 1991-2014 has been negligible. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  7. Estimates of Workers with Noise-Induced Hearing Loss and Population at Risk

    Science.gov (United States)

    Miyakita, T.; Ueda, A.

    1997-08-01

    Towards the goal of protecting workers from damage due to noise exposure, a vast store of knowledge has been generated about its nature, etiology and time course. There still exists, however, a strong need to reclarify the locations, nature and magnitude of the problem of noise-induced hearing loss (NIHL). Based on the rate of positive results in a hearing screening test in the workplace, this paper presents an attempt to estimate the total number of workers with more than 40 dB hearing loss at 4 kHz caused by occupational noise exposure. The estimated values in major industry groups were as follows: about 780 000 in manufacturing; 410 000 in construction; 360 000 in agriculture; forestry and fishing; and around 2 million in total. Although it is rather difficult to estimate the number of workers exposed to noise above 85 dB(A), it may be reasonable to believe that at least several million workers exposed to noise should be covered by the 1992 guidelines for the prevention of noise hazards.

  8. Neutrophilia, gelatinase release and microvascular leakage induced by human mast cell tryptase in a mouse model: Lack of a role of protease-activated receptor 2 (PAR2).

    Science.gov (United States)

    Khedr, M E M S; Abdelmotelb, A M; Pender, S L F; Zhou, X; Walls, A F

    2018-05-01

    Tryptase, the most abundant protease of the human mast cell, has been implicated as a key mediator of allergic inflammation that acts through activation of PAR2. To investigate the contribution of PAR2 in the pro-inflammatory actions mediated by tryptase in a mice model. We have injected recombinant human βII-tryptase into the peritoneum of PAR2-deficient and wild-type C57BL/6 mice. After 6, 12 and 24 hours, mice were killed, peritoneal lavage performed and inflammatory changes investigated. Tryptase stimulated an increase in neutrophil numbers in the peritoneum, but responses did not differ between PAR2-deficient and wild-type mice. Heat inactivation of tryptase or pre-incubation with a selective tryptase inhibitor reduced neutrophilia, but neutrophil accumulation was not elicited with a peptide agonist of PAR2 (SLIGRL-NH 2 ). Zymography indicated that tryptase stimulated the release of matrix metalloproteinases (MMP) 2 and 9 in the peritoneum of both mouse strains. Studies involving immunomagnetic isolation of neutrophils suggested that neutrophils represent the major cellular source of tryptase-induced MMP2 and MMP9. At 24 hours after tryptase injection, there was increased microvascular leakage as indicated by high levels of albumin in peritoneal lavage fluid, and this appeared to be partially abolished by heat-inactivating tryptase or addition of a protease inhibitor. There was no corresponding increase in levels of histamine or total protein. The extent of tryptase-induced microvascular leakage or gelatinase release into the peritoneum did not differ between PAR2-deficient and wild-type mice. Our findings indicate that tryptase is a potent stimulus for neutrophil accumulation, MMP release and microvascular leakage. Although these actions required an intact catalytic site, the primary mechanism of tryptase in vivo would appear to involve processes independent of PAR2. © 2018 The Authors. Clinical & Experimental Allergy Published by John Wiley & Sons Ltd.

  9. Do Hearing Protectors Protect Hearing?

    Science.gov (United States)

    Groenewold, Matthew R.; Masterson, Elizabeth A.; Themann, Christa L.; Davis, Rickie R.

    2015-01-01

    Background We examined the association between self-reported hearing protection use at work and incidence of hearing shifts over a 5-year period. Methods Audiometric data from 19,911 workers were analyzed. Two hearing shift measures—OSHA standard threshold shift (OSTS) and high-frequency threshold shift (HFTS)—were used to identify incident shifts in hearing between workers’ 2005 and 2009 audiograms. Adjusted odds ratios were generated using multivariable logistic regression with multi-level modeling. Results The odds ratio for hearing shift for workers who reported never versus always wearing hearing protection was nonsignificant for OSTS (OR 1.23, 95% CI 0.92–1.64) and marginally significant for HFTS (OR 1.26, 95% CI 1.00–1.59). A significant linear trend towards increased risk of HFTS with decreased use of hearing protection was observed (P = 0.02). Conclusion The study raises concern about the effectiveness of hearing protection as a substitute for noise control to prevent noise-induced hearing loss in the workplace. Am. J. Ind. Med. 57:1001–1010, 2014. Published 2014. This article is a U.S. Government work and is in the public domain in the USA. PMID:24700499

  10. Hearing Aid-Induced Plasticity in the Auditory System of Older Adults: Evidence from Speech Perception

    Science.gov (United States)

    Lavie, Limor; Banai, Karen; Karni, Avi; Attias, Joseph

    2015-01-01

    Purpose: We tested whether using hearing aids can improve unaided performance in speech perception tasks in older adults with hearing impairment. Method: Unaided performance was evaluated in dichotic listening and speech-­in-­noise tests in 47 older adults with hearing impairment; 36 participants in 3 study groups were tested before hearing aid…

  11. Ferulic acid promotes survival and differentiation of neural stem cells to prevent gentamicin-induced neuronal hearing loss.

    Science.gov (United States)

    Gu, Lintao; Cui, Xinhua; Wei, Wei; Yang, Jia; Li, Xuezhong

    2017-11-15

    Neural stem cells (NSCs) have exhibited promising potential in therapies against neuronal hearing loss. Ferulic acid (FA) has been widely reported to enhance neurogenic differentiation of different stem cells. We investigated the role of FA in promoting NSC transplant therapy to prevent gentamicin-induced neuronal hearing loss. NSCs were isolated from mouse cochlear tissues to establish in vitro culture, which were then treated with FA. The survival and differentiation of NSCs were evaluated. Subsequently, neurite outgrowth and excitability of the in vitro neuronal network were assessed. Gentamicin was used to induce neuronal hearing loss in mice, in the presence and absence of FA, followed by assessments of auditory brainstem response (ABR) and distortion product optoacoustic emissions (DPOAE) amplitude. FA promoted survival, neurosphere formation and differentiation of NSCs, as well as neurite outgrowth and excitability of in vitro neuronal network. Furthermore, FA restored ABR threshold shifts and DPOAE in gentamicin-induced neuronal hearing loss mouse model in vivo. Our data, for the first time, support potential therapeutic efficacy of FA in promoting survival and differentiation of NSCs to prevent gentamicin-induced neuronal hearing loss. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Safety and otoprotection of metformin in radiation-induced sensorineural hearing loss in the guinea pig.

    Science.gov (United States)

    Mujica-Mota, Mario A; Salehi, Pezhman; Devic, Slobodan; Daniel, Sam J

    2014-05-01

    There is currently no treatment available to prevent radiation-induced sensorineural hearing loss. Metformin has antineoplastic effects and is able to regulate the mitochondrial production of reactive oxygen species after cellular stress, which is one of the mechanisms involved in apoptosis after radiation damage. The objective of this study was to determine the safety and radioprotective properties of metformin against radiation-induced cochlear damage both in vitro and in vivo. In vitro and prospective animal study. Animal Care Facilities of the Montreal Children's Hospital Research Institute. Cultured auditory hair cells (HEI-OC1) were exposed to different concentrations of metformin to determine its safety. Cells were incubated with different metformin concentrations and subjected to radiation. Cell viability after experiments was determined with the 3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium (MTS) assay. Sixteen guinea pigs were divided in 2 groups: drinking tap water (n = 8) and drinking water containing metformin (n = 8). The animals were unilaterally irradiated for 20 days (total dose 70 Gy), and the ears were divided in 4 groups: control (n = 8), irradiated (n = 8), metformin (n = 8), and experimental (n = 8). Auditory brainstem responses were assessed before and 1, 6, and 16 weeks after completion of radiotherapy. Metformin was not cytotoxic or radioprotective in cultured auditory hair cells. Experimental ears had less hearing loss than radiated ones; however, differences were not statistically significant (P > .05). Metformin is not ototoxic or radioprotective in vitro or in vivo. Ears solely subjected to metformin had better hearing thresholds than the rest of the groups.

  13. Exposure to music and noise-induced hearing loss (NIHL among professional pop/rock/jazz musicians

    Directory of Open Access Journals (Sweden)

    Dana N Halevi-Katz

    2015-01-01

    Full Text Available Noise-induced hearing loss (NIHL has been extensively studied in industrial work environments. With the advent of new technologies, loud music has been increasingly affecting listeners outside of the industrial setting. Most research on the effects of music and hearing loss has focused on classical musicians. The purpose of the current study was to examine the relationship between the amount of experience a professional pop/rock/jazz musician has and objective and subjective variables of the musician′s hearing loss. This study also examined professional pop/rock/jazz musicians′ use of hearing protection devices in relation to the extent of their exposure to amplified music. Forty-four pop/rock/jazz musicians were interviewed using the Pop/Rock/Jazz Musician′s Questionnaire (PRJMQ in order to obtain self-reported symptoms of tinnitus and hyperacusis. Forty-two of the subjects were also tested for air-conduction hearing thresholds in the frequency range of 1-8 kHz. Results show that the extent of professional pop/rock/jazz musicians′ exposure to amplified music was related to both objective and subjective variables of hearing loss: Greater musical experience was positively linked to higher hearing thresholds in the frequency range of 3-6 kHz and to the subjective symptom of tinnitus. Weekly hours playing were found to have a greater effect on hearing loss in comparison to years playing. Use of hearing protection was not linked to the extent of exposure to amplified music. It is recommended that further research be conducted with a larger sample, in order to gain a greater understanding of the detrimental effects of hours playing versus years playing.

  14. Exposure to music and noise-induced hearing loss (NIHL) among professional pop/rock/jazz musicians.

    Science.gov (United States)

    Halevi-Katz, Dana N; Yaakobi, Erez; Putter-Katz, Hanna

    2015-01-01

    Noise-induced hearing loss (NIHL) has been extensively studied in industrial work environments. With the advent of new technologies, loud music has been increasingly affecting listeners outside of the industrial setting. Most research on the effects of music and hearing loss has focused on classical musicians. The purpose of the current study was to examine the relationship between the amount of experience a professional pop/rock/jazz musician has and objective and subjective variables of the musician's hearing loss. This study also examined professional pop/rock/jazz musicians' use of hearing protection devices in relation to the extent of their exposure to amplified music. Forty-four pop/rock/jazz musicians were interviewed using the Pop/Rock/Jazz Musician's Questionnaire (PRJMQ) in order to obtain self-reported symptoms of tinnitus and hyperacusis. Forty-two of the subjects were also tested for air-conduction hearing thresholds in the frequency range of 1-8 kHz. Results show that the extent of professional pop/rock/jazz musicians' exposure to amplified music was related to both objective and subjective variables of hearing loss: Greater musical experience was positively linked to higher hearing thresholds in the frequency range of 3-6 kHz and to the subjective symptom of tinnitus. Weekly hours playing were found to have a greater effect on hearing loss in comparison to years playing. Use of hearing protection was not linked to the extent of exposure to amplified music. It is recommended that further research be conducted with a larger sample, in order to gain a greater understanding of the detrimental effects of hours playing versus years playing.

  15. Effects of babassu nut oil on ischemia/reperfusion-induced leukocyte adhesion and macromolecular leakage in the microcirculation: Observation in the hamster cheek pouch

    Directory of Open Access Journals (Sweden)

    Barbosa Maria do

    2012-11-01

    Full Text Available Abstract Background The babassu palm tree is native to Brazil and is most densely distributed in the Cocais region of the state of Maranhão, in northeastern Brazil. In addition to the industrial use of refined babassu oil, the milk, the unrefined oil and the nuts in natura are used by families from several communities of African descendants as one of the principal sources of food energy. The objective of this study was to evaluate the effects of babassu oil on microvascular permeability and leukocyte-endothelial interactions induced by ischemia/reperfusion using the hamster cheek pouch microcirculation as experimental model. Methods Twice a day for 14 days, male hamsters received unrefined babassu oil (0.02 ml/dose [BO-2 group], 0.06 ml/dose [BO-6 group], 0.18 ml/dose [BO-18 group] or mineral oil (0.18 ml/dose [MO group]. Observations were made in the cheek pouch and macromolecular permeability increase induced by ischemia/reperfusion (I/R or topical application of histamine, as well as leukocyte-endothelial interaction after I/R were evaluated. Results The mean value of I/R-induced microvascular leakage, determined during reperfusion, was significantly lower in the BO-6 and BO-18 groups than in the MO one (P Conclusions Our findings suggest that unrefined babassu oil reduced microvascular leakage and protected against histamine-induced effects in postcapillary venules and highlights that these almost unexploited nut and its oil might be secure sources of food energy.

  16. Vibration induced hearing loss in guinea pig cochlea: expression of TNF-alpha and VEGF.

    Science.gov (United States)

    Zou, Jing; Pyykkö, Ilmari; Sutinen, Päivi; Toppila, Esko

    2005-04-01

    Transcranial vibration was applied for seven animals at a frequency of 250 Hz for 15 min, and five animals were used as normal controls to investigate cellular and molecular mechanism linked to vibration-induced hearing loss in animal model. Compound action potential (CAP) thresholds were measured by round window niche electrode. The expression of tumour necrosis factor alpha (TNF-alpha) and its receptors (TNF R1, TNF R2), vascular endothelium growth factor (VEGF) and its receptors (VEGF R1, VEGF R2) were analysed by immunohistochemistry. Transcranial vibration caused expression of TNF-alpha, TNF R1 and TNF R2 in the cochlea and the expression of TNF R2 was stronger than that of TNF R1. Vibration also induced VEGF and VEGF R2 expression in the cochlea. The average immediate hearing loss was 62 dB and after three days still 48 dB. It is concluded that transcranial vibration as during temporal bone drilling produces cochlear shear stress that is connected with up-regulation of TNF-alpha and its receptors. Also VEGF and VEGF R2 are up-regulated. These responses may be linked to both the damage and repair process of the cochlea.

  17. Corrosion Induced Leakage Problem of the Radial Beam Port 1 of BAEC Triga Mark-II Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kalam, A.; Salam, M. A.; Sarder, M. A.; Rahman, M. M.; Rahman, M.; Rahman, A.; Chowdhury, A. Z.; Uddin, M. S.; Haque, M. M.; Zulquarnain, M.A., E-mail: kalambaec@yahoo.com [Reactor Operation and Maintenance Unit, Atomic Energy Research Establishment (AERE), Dhaka (Bangladesh)

    2014-08-15

    The BAEC reactor has so far been operated as per the technical specifications and procedures laid down in the SAR of the research reactor. The BP leakage problem of the BAEC research reactor was an issue that could lead to a situation close to a LOCA. Therefore, the matter was handled carefully, taking all measures so that such an incident could be prevented. Assistance of agencies outside BAEC was taken for solving the problem. It is understood that the silicone rubber lining of the encirclement clamp may become damaged by neutron irradiation. Therefore, while designing the clamp, provisions were kept such that it can be dismantled and reinstalled again following lining replacement. As a moderately aged facility, the ageing management BAEC TRIGA research reactor deserves significant attention. BAEC, together with its strategic partners, are doing what is needed in this regard.

  18. Effect of Ascorbic Acid on Noise Induced Hearing Loss in Rats

    Directory of Open Access Journals (Sweden)

    Ziba Loukzadeh

    2015-07-01

    Full Text Available Introduction: After presbycusis, noise-induced hearing loss is the second most common cause of acquired hearing loss. Numerous studies have shown that high-intensity noise exposure increases free radical species; therefore, use of antioxidants to detoxify the free radicals can prevent cellular damage in the cochlea. We studied the potential hearing protective effect of different doses of ascorbic acid administered prior to noise exposure in rats.   Materials and Methods: Twenty-four male albino Wistar rats were randomly allocated into four groups: groups A, B, and C received 1250, 250, and 50 mg/kg/day of ascorbic acid, respectively, and group D acted as the control group. After 14 days of ascorbic acid administration, the rats were exposed to noise (105 dB sound pressure level for 2 h. Distortion product otoacoustic emissions (DPOAE were recorded prior to starting the ascorbic acid as baseline and 1 h after the noise exposure.   Results: The amplitude decrease was 14.99 dB for group A, 16.11 dB for group B, 28.82 dB for group C, and 29.91 dB for the control group. Moderate and high doses of ascorbic acid significantly reduced the transient threshold shift in the rats.   Conclusion:  The results of present study support the concept of cochlea protection by antioxidant agents. This dose-dependent protective effect was shown through the use of ascorbic acid treatment prior to noise exposure.

  19. Noise-induced hearing loss induces loudness intolerance in a rat Active Sound Avoidance Paradigm (ASAP).

    Science.gov (United States)

    Manohar, Senthilvelan; Spoth, Jaclyn; Radziwon, Kelly; Auerbach, Benjamin D; Salvi, Richard

    2017-09-01

    Hyperacusis is a loudness hypersensitivity disorder in which moderate-intensity sounds are perceived as extremely loud, aversive and/or painful. To assess the aversive nature of sounds, we developed an Active Sound Avoidance Paradigm (ASAP) in which rats altered their place preference in a Light/Dark shuttle box in response to sound. When no sound (NS) was present, rats spent more than 95% of the time in the Dark Box versus the transparent Light Box. However, when a 60 or 90 dB SPL noise (2-20 kHz, 2-8 kHz, or 16-20 kHz bandwidth) was presented in the Dark Box, the rats'' preference for the Dark Box significantly decreased. Percent time in the dark decreased as sound intensity in the Dark Box increased from 60 dB to 90 dB SPL. Interestingly, the magnitude of the decrease was not a monotonic function of intensity for the 16-20 kHz noise and not related to the bandwidth of the 2-20 kHz and 2-8 kHz noise bands, suggesting that sound avoidance is not solely dependent on loudness but the aversive quality of the noise as well. Afterwards, we exposed the rats for 28 days to a 16-20 kHz noise at 102 dB SPL; this exposure produced a 30-40 dB permanent threshold shift at 16 and 32 kHz. Following the noise exposure, the rats were then retested on the ASAP paradigm. High-frequency hearing loss did not alter Dark Box preference in the no-sound condition. However, when the 2-20 kHz or 2-8 kHz noise was presented at 60 or 90 dB SPL, the rats avoided the Dark Box significantly more than they did before the exposure, indicating these two noise bands with energy below the region of hearing loss were perceived as more aversive. In contrast, when the 16-20 kHz noise was presented at 60 or 90 dB SPL, the rats remained in the Dark Box presumably because the high-frequency hearing loss made 16-20 kHz noise less audible and less aversive. These results indicate that when rats develop a high-frequency hearing loss, they become less tolerant of low frequency noise, i

  20. Noise-induced hearing loss in agriculture: Creating partnerships to overcome barriers and educate the community on prevention

    Directory of Open Access Journals (Sweden)

    Janet J Ehlers

    2011-01-01

    Full Text Available Noise-induced hearing loss (NIHL is a common and preventable injury for farmers. Farmers are frequently exposed to excessive noise, ranking among the top three occupations and industries with the highest risk for hearing loss. Use of hearing protection among farmers is not common. Although the age when NIHL begins among farmers is unknown, its prevalence is higher among male adolescents who live and work on farms. The purpose of this paper is to describe how NIOSH created partnerships to promote hearing conservation for this hard-to-reach population. Partnerships included organizations and individuals who were trusted sources of information for the target population, young farmers 14-35 years of age and their families, and those who had linkages in rural communities. NIOSH engaged partners through exhibits and train-the-trainer workshops at state or national conventions. NIOSH workshops included basic information on NIHL as well as information on free or low-lost resources that participants could use in training others at schools and community events. People with hearing conservation expertise have an important role and many opportunities to improve the knowledge and implementation of hearing conservation among those in agriculture.

  1. [Hydroxychloroquine-induced hearing loss: First case of positive rechallenge and analysis of the French pharmacovigilance database].

    Science.gov (United States)

    Chatelet, J-N; Auffret, M; Combret, S; Bondon-Guitton, E; Lambert, M; Gautier, S

    2017-05-01

    Several cases of hearing loss induced by hydroxychloroquine have been reported in the literature but the role of hydroxychloroquine still remains debated. We report the first case, to our knowledge, of hearing loss induced by hydroxychloroquine with a positive re challenge in a woman treated for systemic lupus. An analysis of the French pharmacovigilance database allowed to identify 23 additional cases of hearing loss in patients treated with hydroxychloroquine and, among them, 8 had systemic lupus. Despite an excellent tolerance and high efficacy-side effect ratio, this case report adds some evidence for an otoxicity of hydroxychloroquine. Copyright © 2016 Société Nationale Française de Médecine Interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  2. Relationship between changes in the cochlear blood flow and disorder of hearing function induced by blast injury in guinea pigs.

    Science.gov (United States)

    Chen, Wei; Wang, Jianmin; Chen, Jing; Chen, Jichuan; Chen, Zhiqiang

    2013-01-01

    The auditory system is the most susceptible to damages from blast waves. Blast injuries always lead to varying degrees of hearing impairment. Although a disorder of the cochlear blood flow (CoBF) has been considered to be related to many pathological processes of the auditory system and to contribute to various types of hearing loss, changes in the CoBF induced by blast waves and the relationship between such changes and hearing impairment are undefined. To observe the changes in the cochlear microcirculation after exposure to an explosion blast, investigate the relationship between changes in the CoBF and hearing impairment and subsequently explore the mechanism responsible for the changes in the CoBF, we detected the perfusion of the cochlear microcirculation and hearing threshold shift after exposure to an explosion blast. Then, an N-nitro-L-arginine-methyl ester (L-NAME, NO synthase inhibitor) solution and artificial perilymph were applied to the round window (RW) of the cochlea before the blast exposure, followed by an evaluation of the CoBF and hearing function. The results indicated that the changes in the CoBF were correlated to the strength of the blast wave. The cochlear blood flow significantly increased when the peak value of the blast overpressure was greater than approximately 45 kPa, and there was no significant change in the cochlear blood flow when the peak value of the blast overpressure was less than approximately 35 kPa. Following local administration of the NO synthase inhibitor L-NAME, the increase in the CoBF induced by the blast was inhibited, and this reduction was significantly associated with the hearing threshold.

  3. Macrophage recruitment, but not interleukin 1 beta activation, enhances noise-induced hearing damage.

    Science.gov (United States)

    Mizushima, Yu; Fujimoto, Chisato; Kashio, Akinori; Kondo, Kenji; Yamasoba, Tatsuya

    2017-11-18

    It has been suggested that macrophages or inflammatory monocytes participate in the pathology of noise-induced hearing loss (NIHL), but it is unclear how extensively these cells contribute to the development of temporary and/or permanent NIHL. To address this question, we used clodronate liposomes to deplete macrophages and monocytes. After clodronate liposome injection, mice were exposed to 4-kHz octave band noise at 121 dB for 4 h. Compared to vehicle-injected controls, clodronate-treated mice exhibited significantly reduced permanent threshold shifts at 4 and 8 kHz and significantly smaller outer hair cell losses in the lower-apical cochlear turn. Following noise exposure, the stria vascularis had significantly more cells expressing the macrophage-specific protein F4/80, and this effect was significantly suppressed by clodronate treatment. These F4/80-positive cells expressed interleukin 1 beta (IL-1β), which noise exposure activated. However, IL-1β deficient mice did not exhibit significant resistance to intense noise when compared to wild-type mice. These findings suggest that macrophages that enter the cochlea after noise exposure are involved in NIHL, whereas IL-1β inhibition does not reverse this cochlear damage. Therefore, macrophages may be a promising therapeutic target in human sensorineural hearing losses such as NIHL. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Falls risk and hospitalization among retired workers with occupational noise-induced hearing loss.

    Science.gov (United States)

    Girard, Serge André; Leroux, Tony; Verreault, René; Courteau, Marilène; Picard, Michel; Turcotte, Fernand; Baril, Julie

    2014-03-01

    This study sought to ascertain whether occupational noise-induced hearing loss (NIHL) increased the risk of falls requiring hospitalization among retired workers. The study population consisted of males (age ≥ 65) with an average occupational noise exposure of 30.6 years and whose mean bilateral hearing loss was 42.2 dB HL at 3, 4, and 6 kHz. Seventy-two retired workers admitted to hospitals after a fall were matched with 216 controls from the same industrial sectors. Conditional logistic regression models were used to estimate the risk (odds ratio; [OR]) of falls leading to hospitalization by NIHL categories. Results showed a relationship between severe NIHL (≥ 52.5 dB HL) and the occurrence of a fall (OR: 1.97, CI95%: 1.001-3.876). Reducing falls among seniors fosters the maintenance of their autonomy. There is a definite need to acquire knowledge about harmful effects of occupational noise to support the prevention of NIHL and ensure healthier workplaces.

  5. The consequences of noise-induced hearing loss on dairy farm communities in New Zealand.

    Science.gov (United States)

    Canton, Karen; Williams, Warwick

    2012-01-01

    The objective of this study was to investigate how noise-induced hearing loss (NIHL) or noise injury (NI) affects individuals and others of dairy farm communities in New Zealand. Using "grab" or opportunistic sampling at DairyNZ discussion groups and a recreational function, a survey questionnaire was completed by 74 participants from two dairy farming communities in New Zealand. Self-reported hearing difficulties were highlighted by 48% (42) of the 74 participants. The effects of NI on individuals and others included communication difficulties leading to the development of coping strategies, social isolation; decreased employment opportunities, loss of productivity, and increased effort and adjustments by family and work colleagues. Frustration, anxiety, stress, resentment, depression, and fatigue are also negative consequences that may contribute to a loss of quality of life and contribute to further health costs. Increased lateness, absenteeism, sickness and other behavioral aspects were not expressed as normal issues in the workplace, as the majority of the individuals are/were self-employed or working in a family business. This study shows that each year in New Zealand NI results in significant negative social, psychological, and economic consequences for those individuals affected, along with their families, friends, and work colleagues.

  6. Ion induced intermixing and consequent effects on the leakage currents in HfO{sub 2}/SiO{sub 2}/Si systems

    Energy Technology Data Exchange (ETDEWEB)

    Manikanthababu, N.; Saikiran, V.; Pathak, A.P.; Rao, S.V.S.N. [University of Hyderabad, School of Physics, Hyderabad (India); Chan, T.K.; Vajandar, S.; Osipowicz, T. [National University of Singapore, Department of Physics, Centre for Ion Beam Applications (CIBA), Singapore (Singapore)

    2017-05-15

    Atomic layer deposited (ALD) samples with layer stacks of HfO{sub 2} (3 nm)/SiO{sub 2} (0.7 nm)/Si were subjected to 120 MeV Au ion irradiation at different fluences to study intermixing effects across the HfO{sub 2}/SiO{sub 2} interface. High-resolution Rutherford backscattering spectrometry (HRBS) and X-ray reflectivity (XRR) measurements confirm an increase in the interlayer thickness as a result of SHI induced intermixing effects. Current-voltage (I-V) measurements reveal an order of magnitude difference in the leakage current density between the pristine and irradiated samples. This can be explained by considering the increased physical thickness of interlayer (HfSiO). Furthermore, the samples were subjected to rapid thermal annealing (RTA) process to analyze annealing kinetics. (orig.)

  7. Evaluation of the current practices of noise-induced hearing loss (NIHL) awareness training in the South African mining industry

    CSIR Research Space (South Africa)

    Edwards, AL

    2015-01-01

    Full Text Available This study aimed to evaluate the current practices in relation to best practice criteria and make recommendations for improvements to noise-induced hearing loss (NIHL) awareness training in the South African mining industry. A survey tool based...

  8. Personal cassette players ('Walkman'). Do they cause noise-induced hearing loss?

    Science.gov (United States)

    Turunen-Rise, I; Flottorp, G; Tvete, O

    1991-01-01

    Playing selected types of music on five different personal cassette players (PCPs) and using different gain (volume) settings, A-weighted maximum and equivalent sound pressure levels (SPLs) were measured on KEMAR (Knowles Electronics Manikin for Acoustic Research). The octave band SPLs were measured on KEMAR ear and transformed to field values in order to compare measured values with the Norwegian noise risk criteria. Temporary threshold shifts (TTS) measured in 6 subjects after listening to two different pop music cassettes on one PCP in two separate sessions, are presented. Based upon these studies we conclude that the risk of acquiring permanent noise-induced hearing loss (NIHL) from use of PCP is very small for what we found to be normal listening conditions.

  9. Acrylonitrile potentiates hearing loss and cochlear damage induced by moderate noise exposure in rats

    International Nuclear Information System (INIS)

    Pouyatos, BenoIt; Gearhart, Caroline A.; Fechter, Laurence D.

    2005-01-01

    The diversity of chemical and drugs that can potentiate noise-induced hearing loss (NIHL) has impeded efforts to predict such interactions. We have hypothesized that chemical contaminants that disrupt intrinsic antioxidant defenses hold significant risk for potentiating NIHL. If this is true, then acrylonitrile (ACN) would be expected to potentiate NIHL. ACN, one of the 50 most commonly used chemicals in the United States, is metabolized via two pathways that are likely to disrupt intrinsic reactive oxygen species (ROS) buffering systems: (1) it conjugates glutathione, depleting this important antioxidant rapidly; (2) a second pathway involves the formation of cyanide, which can inhibit superoxide dismutase. We hypothesized that moderate noise exposure, that does not produce permanent hearing loss by itself, could initiate oxidative stress and that ACN could render the inner ear more sensitive to noise by disrupting intrinsic antioxidant defenses. Temporary and persistent effects of ACN alone (50 mg/kg, sc 5 days), noise alone (95 or 97 dB octave band noise, 4 h/day for 5 days), or ACN in combination with noise were determined using distortion product otoacoustic emissions (DPOAEs) and compound action potential (CAP) amplitudes. Histopathological damage to hair cells resulting from these treatments was also investigated using surface preparations of the organ of Corti. Individually, neither ACN nor noise exposures caused any permanent hearing or hair cell loss; only a reversible temporary threshold shift was measured in noise-exposed animals. However, when given in combination, ACN and noise induced permanent threshold shifts (13-16 dB between 7 and 40 kHz) and a decrease in DPOAE amplitudes (up to 25 dB at 19 kHz), as well as significant outer hair cell (OHC) loss (up to 20% in the first row between 13 and 47 kHz). This investigation demonstrates that ACN can potentiate NIHL at noise levels that are realistic in terms of human exposure, and that the OHCs are the

  10. Digital music exposure reliably induces temporary threshold shift in normal-hearing human subjects.

    Science.gov (United States)

    Le Prell, Colleen G; Dell, Shawna; Hensley, Brittany; Hall, James W; Campbell, Kathleen C M; Antonelli, Patrick J; Green, Glenn E; Miller, James M; Guire, Kenneth

    2012-01-01

    One of the challenges for evaluating new otoprotective agents for potential benefit in human populations is the availability of an established clinical paradigm with real-world relevance. These studies were explicitly designed to develop a real-world digital music exposure that reliably induces temporary threshold shift (TTS) in normal-hearing human subjects. Thirty-three subjects participated in studies that measured effects of digital music player use on hearing. Subjects selected either rock or pop music, which was then presented at 93 to 95 (n = 10), 98 to 100 (n = 11), or 100 to 102 (n = 12) dBA in-ear exposure level for a period of 4 hr. Audiograms and distortion product otoacoustic emissions (DPOAEs) were measured before and after music exposure. Postmusic tests were initiated 15 min, 1 hr 15 min, 2 hr 15 min, and 3 hr 15 min after the exposure ended. Additional tests were conducted the following day and 1 week later. Changes in thresholds after the lowest-level exposure were difficult to distinguish from test-retest variability; however, TTS was reliably detected after higher levels of sound exposure. Changes in audiometric thresholds had a "notch" configuration, with the largest changes observed at 4 kHz (mean = 6.3 ± 3.9 dB; range = 0-14 dB). Recovery was largely complete within the first 4 hr postexposure, and all subjects showed complete recovery of both thresholds and DPOAE measures when tested 1 week postexposure. These data provide insight into the variability of TTS induced by music-player use in a healthy, normal-hearing, young adult population, with music playlist, level, and duration carefully controlled. These data confirm the likelihood of temporary changes in auditory function after digital music-player use. Such data are essential for the development of a human clinical trial protocol that provides a highly powered design for evaluating novel therapeutics in human clinical trials. Care must be taken to fully inform potential subjects in

  11. Digital music exposure reliably induces temporary threshold shift (TTS) in normal hearing human subjects

    Science.gov (United States)

    Le Prell, C. G.; Dell, S.; Hensley, B.; Hall, J. W.; Campbell, K. C. M.; Antonelli, P. J.; Green, G. E.; Miller, J. M.; Guire, K.

    2012-01-01

    Objectives One of the challenges for evaluating new otoprotective agents for potential benefit in human populations is availability of an established clinical paradigm with real world relevance. These studies were explicitly designed to develop a real-world digital music exposure that reliably induces temporary threshold shift (TTS) in normal hearing human subjects. Design Thirty-three subjects participated in studies that measured effects of digital music player use on hearing. Subjects selected either rock or pop music, which was then presented at 93–95 (n=10), 98–100 (n=11), or 100–102 (n=12) dBA in-ear exposure level for a period of four hours. Audiograms and distortion product otoacoustic emissions (DPOAEs) were measured prior to and after music exposure. Post-music tests were initiated 15 min, 1 hr 15 min, 2 hr 15 min, and 3 hr 15 min after the exposure ended. Additional tests were conducted the following day and one week later. Results Changes in thresholds after the lowest level exposure were difficult to distinguish from test-retest variability; however, TTS was reliably detected after higher levels of sound exposure. Changes in audiometric thresholds had a “notch” configuration, with the largest changes observed at 4 kHz (mean=6.3±3.9dB; range=0–13 dB). Recovery was largely complete within the first 4 hours post-exposure, and all subjects showed complete recovery of both thresholds and DPOAE measures when tested 1-week post-exposure. Conclusions These data provide insight into the variability of TTS induced by music player use in a healthy, normal-hearing, young adult population, with music playlist, level, and duration carefully controlled. These data confirm the likelihood of temporary changes in auditory function following digital music player use. Such data are essential for the development of a human clinical trial protocol that provides a highly powered design for evaluating novel therapeutics in human clinical trials. Care must be

  12. The Antioxidant Effect of Rosmarinic Acid by Different Delivery Routes in the Animal Model of Noise-Induced Hearing Loss.

    Science.gov (United States)

    Fetoni, Anna R; Eramo, Sara Letizia Maria; Di Pino, Antonella; Rolesi, Rolando; Paciello, Fabiola; Grassi, Claudio; Troiani, Diana; Paludetti, Gaetano

    2018-03-01

    Trans-tympanic Rosmarinic Acid (RA), as compared with the systemic administration, protects against noise-induced auditory hair cell and hearing losses in rats in vivo. ROS production, lipoperoxidative damage, and an imbalance of antioxidant defences play a significant role in noise-induced hearing loss. Several molecules with antioxidant properties have been tested to restore redox homeostasis; however, drug delivery system represents a challenge for their effectiveness. In our model, acute and intense noise exposure induces hearing loss, hair cell death, and oxidative stress, with an increase in superoxide production and over-expression of lipid peroxidation in cochlear structures. RA was administrated in male Wistar rats by trans-tympanic (20 μl) and systemic (10 mg/kg) modality. In systemic administration, RA was injected 1 hour before noise exposure and once daily for the following 3 days. ABRs were measured before and at days 1, 3, 7, and 30 after noise exposure. Rhodamine-phalloidin staining, dihydroethidium and 8-isoprostane immunostainings were performed to assess and quantify outer hair cells loss, superoxide production, and lipid peroxidation in the different experimental groups. Systemic RA administration significantly decreased noise-induced hearing loss and the improvement of auditory function was paralleled by a significant reduction in cochlear oxidative stress. The trans-tympanic modality of drug administration showed a similar degree of protection both at the functional and morphological levels. The effectiveness of RA given via trans-tympanic injection could be interesting for the future application of this minimally-invasive procedure in the treatment of ROS-induced hearing loss.

  13. Evaluation of the Repeatability of the Delta Q Duct Leakage Testing TechniqueIncluding Investigation of Robust Analysis Techniques and Estimates of Weather Induced Uncertainty

    Energy Technology Data Exchange (ETDEWEB)

    Dickerhoff, Darryl; Walker, Iain

    2008-08-01

    The DeltaQ test is a method of estimating the air leakage from forced air duct systems. Developed primarily for residential and small commercial applications it uses the changes in blower door test results due to forced air system operation. Previous studies established the principles behind DeltaQ testing, but raised issues of precision of the test, particularly for leaky homes on windy days. Details of the measurement technique are available in an ASTM Standard (ASTM E1554-2007). In order to ease adoption of the test method, this study answers questions regarding the uncertainty due to changing weather during the test (particularly changes in wind speed) and the applicability to low leakage systems. The first question arises because the building envelope air flows and pressures used in the DeltaQ test are influenced by weather induced pressures. Variability in wind induced pressures rather than temperature difference induced pressures dominates this effect because the wind pressures change rapidly over the time period of a test. The second question needs to answered so that DeltaQ testing can be used in programs requiring or giving credit for tight ducts (e.g., California's Building Energy Code (CEC 2005)). DeltaQ modeling biases have been previously investigated in laboratory studies where there was no weather induced changes in envelope flows and pressures. Laboratory work by Andrews (2002) and Walker et al. (2004) found biases of about 0.5% of forced air system blower flow and individual test uncertainty of about 2% of forced air system blower flow. The laboratory tests were repeated by Walker and Dickerhoff (2006 and 2008) using a new ramping technique that continuously varied envelope pressures and air flows rather than taking data at pre-selected pressure stations (as used in ASTM E1554-2003 and other previous studies). The biases and individual test uncertainties for ramping were found to be very close (less than 0.5% of air handler flow) to those

  14. Strategies for the prevention of MP3-induced hearing loss among adolescents: expert opinions from a Delphi study.

    Science.gov (United States)

    Vogel, Ineke; Brug, Johannes; van der Ploeg, Catharina P B; Raat, Hein

    2009-05-01

    To identify parties involved in the prevention of MP3-induced hearing loss among adolescents and potentially effective prevention strategies and interventions. Thirty experts in fields such as scientific research, medical practice, community health professions, education, youth work, music entertainment, and enforcement authorities participated in a qualitative, electronic, 3-round, Web-based Delphi study. Multiple parties involved in the prevention of MP3-induced hearing loss among adolescents were identified; the most relevant are the adolescents themselves, their parents, manufacturers of MP3 players and earphones, and the authorities. The experts did not expect that adolescents in general would perform the necessary protective behaviors to prevent MP3-induced hearing loss. Two environmental health protection measures were identified as both relevant and feasible to be implemented (ie, authorities encourage manufacturers to produce safer products, and public health campaigns will be held to improve knowledge of the risks of high-volume music, possible protective measures, and consequences of hearing loss). Authorities, the music industry in general, and especially manufacturers of MP3 players and earphones should recognize their responsibility and create a safer MP3-listening environment by taking measures to protect today's youth from the dangers of listening to high-volume music on MP3 players.

  15. High Intensity Interval Training (HIIT) Induces Specific Changes in Respiration and Electron Leakage in the Mitochondria of Different Rat Skeletal Muscles.

    Science.gov (United States)

    Ramos-Filho, Dionizio; Chicaybam, Gustavo; de-Souza-Ferreira, Eduardo; Guerra Martinez, Camila; Kurtenbach, Eleonora; Casimiro-Lopes, Gustavo; Galina, Antonio

    2015-01-01

    High intensity interval training (HIIT) is characterized by vigorous exercise with short rest intervals. Hydrogen peroxide (H2O2) plays a key role in muscle adaptation. This study aimed to evaluate whether HIIT promotes similar H2O2 formation via O2 consumption (electron leakage) in three skeletal muscles with different twitch characteristics. Rats were assigned to two groups: sedentary (n=10) and HIIT (n=10, swimming training). We collected the tibialis anterior (TA-fast), gastrocnemius (GAST-fast/slow) and soleus (SOL-slow) muscles. The fibers were analyzed for mitochondrial respiration, H2O2 production and citrate synthase (CS) activity. A multi-substrate (glycerol phosphate (G3P), pyruvate, malate, glutamate and succinate) approach was used to analyze the mitochondria in permeabilized fibers. Compared to the control group, oxygen flow coupled to ATP synthesis, complex I and complex II was higher in the TA of the HIIT group by 1.5-, 3.0- and 2.7-fold, respectively. In contrast, oxygen consumed by mitochondrial glycerol phosphate dehydrogenase (mGPdH) was 30% lower. Surprisingly, the oxygen flow coupled to ATP synthesis was 42% lower after HIIT in the SOL. Moreover, oxygen flow coupled to ATP synthesis and complex II was higher by 1.4- and 2.7-fold in the GAST of the HIIT group. After HIIT, CS activity increased 1.3-fold in the TA, and H2O2 production was 1.3-fold higher in the TA at sites containing mGPdH. No significant differences in H2O2 production were detected in the SOL. Surprisingly, HIIT increased H2O2 production in the GAST via complex II, phosphorylation, oligomycin and antimycin by 1.6-, 1.8-, 2.2-, and 2.2-fold, respectively. Electron leakage was 3.3-fold higher in the TA with G3P and 1.8-fold higher in the GAST with multiple substrates. Unexpectedly, the HIIT protocol induced different respiration and electron leakage responses in different types of muscle.

  16. High Intensity Interval Training (HIIT Induces Specific Changes in Respiration and Electron Leakage in the Mitochondria of Different Rat Skeletal Muscles.

    Directory of Open Access Journals (Sweden)

    Dionizio Ramos-Filho

    Full Text Available High intensity interval training (HIIT is characterized by vigorous exercise with short rest intervals. Hydrogen peroxide (H2O2 plays a key role in muscle adaptation. This study aimed to evaluate whether HIIT promotes similar H2O2 formation via O2 consumption (electron leakage in three skeletal muscles with different twitch characteristics. Rats were assigned to two groups: sedentary (n=10 and HIIT (n=10, swimming training. We collected the tibialis anterior (TA-fast, gastrocnemius (GAST-fast/slow and soleus (SOL-slow muscles. The fibers were analyzed for mitochondrial respiration, H2O2 production and citrate synthase (CS activity. A multi-substrate (glycerol phosphate (G3P, pyruvate, malate, glutamate and succinate approach was used to analyze the mitochondria in permeabilized fibers. Compared to the control group, oxygen flow coupled to ATP synthesis, complex I and complex II was higher in the TA of the HIIT group by 1.5-, 3.0- and 2.7-fold, respectively. In contrast, oxygen consumed by mitochondrial glycerol phosphate dehydrogenase (mGPdH was 30% lower. Surprisingly, the oxygen flow coupled to ATP synthesis was 42% lower after HIIT in the SOL. Moreover, oxygen flow coupled to ATP synthesis and complex II was higher by 1.4- and 2.7-fold in the GAST of the HIIT group. After HIIT, CS activity increased 1.3-fold in the TA, and H2O2 production was 1.3-fold higher in the TA at sites containing mGPdH. No significant differences in H2O2 production were detected in the SOL. Surprisingly, HIIT increased H2O2 production in the GAST via complex II, phosphorylation, oligomycin and antimycin by 1.6-, 1.8-, 2.2-, and 2.2-fold, respectively. Electron leakage was 3.3-fold higher in the TA with G3P and 1.8-fold higher in the GAST with multiple substrates. Unexpectedly, the HIIT protocol induced different respiration and electron leakage responses in different types of muscle.

  17. The Protective Effect of Conditioning on Noise-Induced Hearing Loss Is Frequency-Dependent

    Directory of Open Access Journals (Sweden)

    Akram Pourbakht

    2012-10-01

    Full Text Available We compared the extent of temporary threshold shift (TTS and hair cell loss following high level 4 kHz noise exposure with those preconditioned with moderate level 1 and 4 kHz octave band noise. Fifteen Male albino guinea pigs (300- 350 g in weight were randomly allocated into three groups: those exposed to 4 kHz octave band noise at 102 dB SPL (group 1, n=5; those conditioned with 1 kHz octave band noise at 85 dB SPL, 6 hours per day for 5 days, then exposed to noise (group 2, n=5; those conditioned with 4 kHz octave band noise at 85 dB SPL, then exposed to noise (group 3, n=5. An hour and one week after noise exposure, threshold shifts were evaluated by auditory-evoked brainstem response (ABR and then animals were euthanized for histological evaluation. We found that TTS and cochlear damage caused by noise exposure were significantly reduced by 1 kHz and 4 kHz conditioning (P<0.001. We also showed that 4 kHz protocol attenuates noise- induced TTS but no significant TTS reduction occurred by 1 kHz conditioning. Both protocol protected noise-induced cochlear damage. We concluded that lower tone conditioning could not protect against higher tone temporary noise-induced hearing loss, thus conditioning is a local acting and frequency-dependent phenomenon.

  18. Cochlea hair cell rescue after a noise-induced hearing loss using a low level laser therapy (LLLT)

    Science.gov (United States)

    Rhee, Chung-Ku; Bahk, Chan Woong; Jung, Jae Yun; Ahn, Jin-Chul; Suh, Myung-Whan

    2011-03-01

    Aim: To see the effect of LLLT on noise-induced hearing loss. Methods: Eleven rats were exposed to noise (120 dB, 16 kHz, 6 h) and left ears were irradiated at 60J/cm2, 830 nm laser for 12 days. Right ears were control. Hearing levels were measured at frequencies of 4, 8, 12, 16, 32 kHz before noise exposure and after 12th irradiations. Results: The initial hearing levels were 26.5+/-4.7, 24.5+/-5.0, 24.0+/-5.2, 24.0+/-3.2, 24.5+/-5.5 dB SPL. After noise exposure, thresholds were 63.5+/-15.1, 64+/-16.8, 71.5+/-11.3, 73.5+/-15.6, 67.5+/-14.4 dB SPL in 4, 8, 12, 16, 32 kHz. After 12th irradiation, thresholds of treated ears recovered significantly 21+/-4.2, 20+/-3.5, 24+/-11.9, 24+/-12.9, 21+/-2.2 dB SPL and that of the untreated right ears measured 36.3+/-22.9, 45+/-15.8, 66.3+/-22.9, 50+/-16.8, 43.8+/-21.4 dB SPL. Conclusion: LLLT may promote recovery of hearing after noiseinduced hearing loss.

  19. Minority Carrier Tunneling and Stress-Induced Leakage Current for p+ gate MOS Capacitors with Poly-Si and PolySi0.7Ge0.3 Gate Material

    NARCIS (Netherlands)

    Houtsma, V.E.; Holleman, J.; Salm, Cora; de Haan, I.R.; Schmitz, Jurriaan; Widdershoven, F.P.; Widdershoven, F.P.; Woerlee, P.H.

    1999-01-01

    In this paper the I-V conduction mechanism for gate injection (-V g), Stress-Induced Leakage Current (SILC) characteristics and time-to-breakdown (tbd) of PMOS capacitors with p+-poly-Si and poly-SiGe gate material on 5.6, 4.8 and 3.1 nm oxide thickness are studied. A model based on Minority Carrier

  20. [A cohort study on occupational noise induced hearing loss in workers at an iron and steel plant].

    Science.gov (United States)

    Yu, S F; Chen, G S; Jiao, J; Gu, G Z; Zhang, H L; Wang, X M; Zhou, W H; Wu, H; Li, Y H; Zheng, Y X

    2017-01-06

    Objective: To analyze the incidence rate of occupational noise-induced hearing loss in noise-exposed workers in an iron and steel plant from 2006 to 2015. Methods: Using a cohort study method, workers exposed to occupational noise from Jan 1, 2006 to Dec 12, 2015 were followed up and the pure tone hearing test was conducted. In total, 6 297 subjects completed two or more physical checks and the pure tone hearing test and were included in the analysis. The noise exposure level at the workplace and the equivalent continuous A-weighted sound pressure level for workers was monitored and the cumulative noise exposure dose was evaluated. The subjects were divided into low, middle and high exposure groups according to the noise exposure level, and the equivalent continuous A-weighted sound pressure level for 8 hours for each group was 80.6-85.0, 85.1-90.0 and 90.1-103.4 dB (A), respectively. While the RR and 95% CI were derived from unconditional logistic regression models. In logistic regression analysis, confounding factors such as age, gender, smoking habit, drinking habit, high temperature exposure and chemical hazards exposure level were controlled. Results: During the follow-up period, 392 cases of occupational noise-induced hearing loss were diagnosed among the 6 297 subjects, with an incidence rate of 6.23%; 318 cases of high-frequency hearing loss were diagnosed, with an incidence rate of 5.05%; and 74 cases of occupational noise-induced deafness were diagnosed, with an incidence rate of 1.18% . The incidence rates of hearing loss among the high, medium and low exposure groups were 9.22% (158/1 737), 6.49% (204/3 142) and 2.08% (30/1 442), respectively; the rates of high-frequency hearing loss were 7.41% (127/1 737), 5.25% (165/3 142) and 1.80% (26/1 442), respectively; and the rates of occupational noise-induced deafness were 1.81% (31/1 737), 1.24% (39/3 142) and 0.28% (4/1 442), respectively. For the groups corresponding to cumulative noise exposure doses of

  1. Subchronic JP-8 jet fuel exposure enhances vulnerability to noise-induced hearing loss in rats.

    Science.gov (United States)

    Fechter, L D; Fisher, J W; Chapman, G D; Mokashi, V P; Ortiz, P A; Reboulet, J E; Stubbs, J E; Lear, A M; McInturf, S M; Prues, S L; Gearhart, C A; Fulton, S; Mattie, D R

    2012-01-01

    Both laboratory and epidemiological studies published over the past two decades have identified the risk of excess hearing loss when specific chemical contaminants are present along with noise. The objective of this study was to evaluate the potency of JP-8 jet fuel to enhance noise-induced hearing loss (NIHL) using inhalation exposure to fuel and simultaneous exposure to either continuous or intermittent noise exposure over a 4-wk exposure period using both male and female Fischer 344 rats. In the initial study, male (n = 5) and female (n = 5) rats received inhalation exposure to JP-8 fuel for 6 h/d, 5 d/wk for 4 wk at concentrations of 200, 750, or 1500 mg/m³. Parallel groups of rats also received nondamaging noise (constant octave band noise at 85 dB(lin)) in combination with the fuel, noise alone (75, 85, or 95 dB), or no exposure to fuel or noise. Significant concentration-related impairment of auditory function measured by distortion product otoacoustic emissions (DPOAE) and compound action potential (CAP) threshold was seen in rats exposed to combined JP-8 plus noise exposure when JP-8 levels of 1500 mg/m³ were presented with trends toward impairment seen with 750 mg/m³ JP-8 + noise. JP-8 alone exerted no significant effect on auditory function. In addition, noise was able to disrupt the DPOAE and increase auditory thresholds only when noise exposure was at 95 dB. In a subsequent study, male (n = 5 per group) and female (n = 5 per group) rats received 1000 mg/m³ JP-8 for 6 h/d, 5 d/wk for 4 wk with and without exposure to 102 dB octave band noise that was present for 15 min out of each hour (total noise duration 90 min). Comparisons were made to rats receiving only noise, and thosereceiving no experimental treatment. Significant impairment of auditory thresholds especially for high-frequency tones was identified in the male rats receiving combined treatment. This study provides a basis for estimating excessive hearing loss under

  2. [Association between eye absent homolog 4 gene polymorphisms and occupational noise-induced hearing loss].

    Science.gov (United States)

    Yang, Q Y; Xu, X R; Jiao, J; Zheng, Y X; He, L H; Yu, S F; Gu, G Z; Chen, G S; Zhou, W H; Wu, H; Li, Y H; Zhang, H L; Zhang, Z R

    2017-01-06

    Objective: To identify the association between genetic polymorphisms in the eye absent homolog 4 (EYA4) gene and noise-induced hearing loss (NIHL). Method: A nested case control study was conducted based on a cohort of noise-exposed subjects. In total, 292 cases were selected from a steel factory from 6 297 subjects during Jan 1, 2006 to Dec 12, 2015,who had an average hearing threshold of more than 40 dB(A); 584 matched control subjects for each case were designated on the basis of matched criteria including same gender, age (±5 years) and duration of exposure to noise (±2 years). What's more, the control group had an average hearing threshold of less than 35 dB(A) in high frequency and less than 25 dB(A) in speech frequency. Four single nucleotide polymorphisms (SNPs) of the EYA4 gene were genotyped using a SNPscan TM multiplex SNP genotyping kit. Hardy-Weinberg equilibrium tests were performed using a χ 2 test for goodness-of-fit for each SNP among the control group, and the effects of genotypes of the EYA4 gene on NIHL were analyzed by logistic regression. The haplotypes were established and their frequencies in the two groups were assessed using Haploview 4.2 and Phase 2.1 software, and interactive effects between haplotypes and cumulative noise exposure were analyzed. Results: The average age of the subjects was (40.1±8.4) years and the average number of noise-exposed working years was 20.3 (8.4, 27.3) years. The range of noise exposure levels and the cumulative noise exposure were 80.2- 98.8 dB (A) and 86.6- 111.2 dB(A) · year, respectively. After adjustment for covariates including height, blood pressure, drinking status and smoking status, in the noise intensity>85 dB (A) group, subjects carrying the rs3813346 TT genotype had a higher NIHL risk than those carrying the GG genotype, and the adjusted OR (95% CI ) value was 2.12 (1.21- 3.69). In the cumulative noise exposure>98 dB (A) · year group, compared with haplotype TGC, haplotype CGT showed a

  3. Drug-induced Defibrinogenation as New Treatment Approach of Acute Hearing Loss in an Animal Model for Inner Ear Vascular Impairment.

    Science.gov (United States)

    Weiss, Bernhard G; Bertlich, Mattis; Bettag, Stephan A; Desinger, Hendrik; Ihler, Friedrich; Canis, Martin

    2017-06-01

    Disturbance of cochlear microcirculation is considered to be the final common pathway of various inner ear diseases. Hyperfibrinogenemia causing increased plasma viscosity is a known risk factor for sudden sensorineural hearing loss and may lead to a critical reduction of cochlear blood flow. The aim of this study was to evaluate the effect of a substantial reduction of plasma fibrinogen levels by drug-induced defibrinogenation for the treatment of acute hearing loss in vivo. Acute hearing loss was induced by hyperfibrinogenemia (i.v. injection of 330 mg/kg BW fibrinogen), using a guinea pig animal model. Parameters of cochlear microcirculation and hearing thresholds were quantified by intravital microscopy and evoked response audiometry. After obtaining baseline values, the course of hearing loss and disturbances of microcirculation were investigated under influence of intravenous defibrinogenation therapy (ancrod), corticosteroid, or placebo treatment, using 5 animals/group. Acute hyperfibrinogenemia caused hearing loss from 10 ± 7 to 26 ± 10 dB SPL at baseline. Drug-induced reduction of fibrinogen levels showed a significant increase of cochlear microcirculation (1.6-fold) and recovered hearing threshold (11 ± 6 dB SPL). Placebo or corticosteroid treatment had no effect on hearing loss (35 ± 7 dB SPL and 32 ± 18 dB SPL, respectively). Acute hyperfibrinogenemia resulted in hearing loss. Drug-induced reduction of elevated fibrinogen levels caused an increase in cochlear blood flow and a decrease in hearing thresholds. Placebo or corticosteroid treatment had no effect. Reduction of plasma fibrinogen levels could serve as a clinical treatment option for acute hearing loss.

  4. Effect of cigarette smoking on noise-induced hearing loss in workers exposed to occupational noise in China.

    Science.gov (United States)

    Tao, Liyuan; Davis, Robert; Heyer, Nicholas; Yang, Qiuling; Qiu, Wei; Zhu, Liangliang; Li, Nan; Zhang, Hua; Zeng, Lin; Zhao, Yiming

    2013-01-01

    Excessive exposure to high noise level environments has the potential to cause noise-induced hearing loss (NIHL), and cigarette smoking has also been shown to have a potential adverse effect on hearing. The aim of this study was to determine whether smoking interacts with noise in the development of hearing loss, and if so, the extent of the contribution from smoking on NIHL. A cross-sectional study was designed to assess the effect of smoking on NIHL in 517 male workers (non-smokers: N = 199; smokers: N = 318) exposed to a high-level industrial noise environment in China. Shift-long temporal waveforms of the noise that workers were exposed to for evaluation of noise exposures, and audiometric threshold measures were obtained on all selected subjects. The subjects used hearing protection devices only within the last 1-2 years. The results suggest that smoking has an adverse effect on NIHL in workers exposed to high level industrial noise, i.e., the median high frequency hearing thresholds were significantly greater in smokers than non-smokers exposed to noise for more than 10 years. This effect was observed at 4.0 and 6.0 kHz. Smoking did not have an adverse effect on NIHL in workers exposed to noise less than 10 years. Multivariate regression analysis revealed that the odds ratio (OR) for high frequency hearing loss (i.e., hearing threshold greater than 40 dB at 4.0 kHz) were 1.94 for smokers in comparison to non-smokers. The results suggest that: (1) smokers have a higher risk of developing high frequency hearing loss than non-smokers with a similar occupational noise exposure, and (2) the interaction between cigarette smoking and high-level noise exposure may be additive. There is a need to develop and analyze a larger database of workers with well-documented exposures and smoking histories for better understanding of the effect of smoking on NIHL incurred from high-level industrial noise exposures. A better understanding of the role of smoking may lead to its

  5. The prevalence of noise-induced occupational hearing loss in dentistry personnel.

    Science.gov (United States)

    Khaimook, Wandee; Suksamae, Puwanai; Choosong, Thitiworn; Chayarpham, Satit; Tantisarasart, Ratchada

    2014-09-01

    Occupational hearing loss is the second most common health problem in the industrialized world. Dental personnel exposed to occupational noise may experience hearing loss. This article compares the prevalence of hearing loss in the general population to that of dental personnel exposed to noise during work hours and identifies risk factors for hearing loss among workers at a dental school. This prospective study included 76 dental personnel on the faculty of dentistry at a major university in Asia who were exposed to noise and 76 individuals in a control group. Nearly 16% of the study group and 21% of the control group had lost hearing, a nonsignificant difference (p = .09). Hearing loss was significantly related to work tenure longer than 15 years and age older than 40 years (p < .001 ).

  6. Reducing Risk of Noise-Induced Hearing Loss in Collegiate Music Ensembles Using Ambient Technology.

    Science.gov (United States)

    Powell, Jason; Chesky, Kris

    2017-09-01

    Student musicians are at risk for noise-induced hearing loss (NIHL) as they develop skills and perform during instructional activities. Studies using longitudinal dosimeter data show that pedagogical procedures and instructor behaviors are highly predictive of NIHL risk, thus implying the need for innovative approaches to increase instructor competency in managing instructional activities without interfering with artistic and academic freedom. Ambient information systems, an emerging trend in human-computer interaction that infuses psychological behavioral theories into technologies, can help construct informative risk-regulating systems. The purpose of this study was to determine the effects of introducing an ambient information system into the ensemble setting. The system used two ambient displays and a counterbalanced within-subjects treatment study design with six jazz ensemble instructors to determine if the system could induce a behavior change that alters trends in measures resulting from dosimeter data. This study assessed efficacy using time series analysis to determine changes in eight statistical measures of behavior over a 9-wk period. Analysis showed that the system was effective, as all instructors showed changes in a combination of measures. This study is in an important step in developing non-interfering technology to reduce NIHL among academic musicians.

  7. Hearing loss

    Science.gov (United States)

    Decreased hearing; Deafness; Loss of hearing; Conductive hearing loss; Sensorineural hearing loss; Presbycusis ... Symptoms of hearing loss may include: Certain sounds seeming too loud Difficulty following conversations when two or more people are talking ...

  8. About Hearing

    Science.gov (United States)

    ... Info to Go » Hearing-Related » About Hearing About Hearing Each child who is deaf or hard of ... the ear to the brain. Implications: When the hearing mechanism is not functioning Hearing may be impacted ...

  9. Land-use Leakage

    Energy Technology Data Exchange (ETDEWEB)

    Calvin, Katherine V.; Edmonds, James A.; Clarke, Leon E.; Bond-Lamberty, Benjamin; Kim, Son H.; Wise, Marshall A.; Thomson, Allison M.; Kyle, G. Page

    2009-12-01

    Leakage occurs whenever actions to mitigate greenhouse gas emissions in one part of the world unleash countervailing forces elsewhere in the world so that reductions in global emissions are less than emissions mitigation in the mitigating region. While many researchers have examined the concept of industrial leakage, land-use policies can also result in leakage. We show that land-use leakage is potentially as large as or larger than industrial leakage. We identify two potential land-use leakage drivers, land-use policies and bioenergy. We distinguish between these two pathways and run numerical experiments for each. We also show that the land-use policy environment exerts a powerful influence on leakage and that under some policy designs leakage can be negative. International “offsets” are a potential mechanism to communicate emissions mitigation beyond the borders of emissions mitigating regions, but in a stabilization regime designed to limit radiative forcing to 3.7 2/m2, this also implies greater emissions mitigation commitments on the part of mitigating regions.

  10. Data leakage quantification

    NARCIS (Netherlands)

    Vavilis, S.; Petkovic, M.; Zannone, N.; Atluri, V.; Pernul, G.

    2014-01-01

    The detection and handling of data leakages is becoming a critical issue for organizations. To this end, data leakage solutions are usually employed by organizations to monitor network traffic and the use of portable storage devices. These solutions often produce a large number of alerts, whose

  11. Modeling valve leakage

    International Nuclear Information System (INIS)

    Bell, S.R.; Rohrscheib, R.

    1994-01-01

    The American Society of Mechanical Engineers (ASME) Code requires individual valve leakage testing for Category A valves. Although the U.S. Nuclear Regulatory Commission (USNRC) has recognized that it is more appropriate to test containment isolation valves in groups, as allowed by 10 CFR 50, Appendix J, a utility seeking relief from these Code requirements must provide technical justification for the relief and establish a conservative alternate acceptance criteria. In order to provide technical justification for group testing of containment isolation valves, Illinois Power developed a calculation (model) for determining the size of a leakage pathway in a valve disc or seat for a given leakage rate. The model was verified experimentally by machining leakage pathways of known size and then measuring the leakage and comparing this value to the calculated value. For the range of values typical of leakage rate testing, the correlation between the experimental values and calculated values was quote good. Based upon these results, Illinois Power established a conservative acceptance criteria for all valves in the inservice testing (IST) program and was granted relief by the USNRC from the individual leakage testing requirements of the ASME Code. This paper presents the results of Illinois Power's work in the area of valve leakage rate testing

  12. The association between low levels of lead in blood and occupational noise-induced hearing loss in steel workers

    International Nuclear Information System (INIS)

    Hwang, Yaw-Huei; Chiang, Han-Yueh; Yen-Jean, Mei-Chu; Wang, Jung-Der

    2009-01-01

    As the use of leaded gasoline has ceased in the last decade, background lead exposure has generally been reduced. The aim of this study was to examine the effect of low-level lead exposure on human hearing loss. This study was conducted in a steel plant and 412 workers were recruited from all over the plant. Personal information such as demographics and work history was obtained through a questionnaire. All subjects took part in an audiometric examination of hearing thresholds, for both ears, with air-conducted pure tones at frequencies of 500, 1000, 2000, 3000, 4000, 6000 and 8000 Hz. Subjects' blood samples were collected and analyzed for levels of manganese, copper, zinc, arsenic, cadmium and lead with inductive couple plasma-mass spectrometry. Meanwhile, noise levels in different working zones were determined using a sound level meter with A-weighting network. Only subjects with hearing loss difference of no more than 15 dB between both ears and had no congenital abnormalities were included in further data analysis. Lead was the only metal in blood found significantly correlated with hearing loss for most tested sound frequencies (p < 0.05 to p < 0.0001). After adjustment for age and noise level, the logistic regression model analysis indicated that elevated blood lead over 7 μg/dL was significantly associated with hearing loss at the sound frequencies of 3000 through 8000 Hz with odds ratios raging from 3.06 to 6.26 (p < 0.05 ∼ p < 0.005). We concluded that elevated blood lead at level below 10 μg/dL might enhance the noise-induced hearing loss. Future research needs to further explore the detailed mechanism.

  13. The association between low levels of lead in blood and occupational noise-induced hearing loss in steel workers

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Yaw-Huei [Institute of Occupational Medicine and Industrial Hygiene, College of Public Health, National Taiwan University, Taipei, Taiwan, ROC Rm. 735, 17, Xu-Zhou Rd., Taipei, Taiwan, ROC (China); Department of Public Health, College of Public Health, National Taiwan University, Taipei, Taiwan, ROC Rm. 735, 17, Xu-Zhou Rd., Taipei, Taiwan, ROC (China); Chiang, Han-Yueh [Institute of Occupational Medicine and Industrial Hygiene, College of Public Health, National Taiwan University, Taipei, Taiwan, ROC Rm. 735, 17, Xu-Zhou Rd., Taipei, Taiwan, ROC (China); Yen-Jean, Mei-Chu [Division of Family Medicine, E-Da Hospital, Taiwan, ROC 1, E-Da Rd., Jiau-Shu Tsuen, Yan-Chau Shiang, Kaohsiung County, Taiwan, ROC (China); I-Shou University, Kaohsiung County, Taiwan, ROC 1, Sec. 1, Syuecheng Rd., Da-Shu Shiang, Kaohsiung County, Taiwan, ROC (China); Wang, Jung-Der, E-mail: jdwang@ntu.edu.tw [Institute of Occupational Medicine and Industrial Hygiene, College of Public Health, National Taiwan University, Taipei, Taiwan, ROC Rm. 735, 17, Xu-Zhou Rd., Taipei, Taiwan, ROC (China); Department of Public Health, College of Public Health, National Taiwan University, Taipei, Taiwan, ROC Rm. 735, 17, Xu-Zhou Rd., Taipei, Taiwan, ROC (China); Department of Internal Medicine, National Taiwan University Hospital and National Taiwan University College of Medicine, Taipei, Taiwan, ROC No. 1, Chang-Teh St., Taipei, Taiwan, ROC (China)

    2009-12-15

    As the use of leaded gasoline has ceased in the last decade, background lead exposure has generally been reduced. The aim of this study was to examine the effect of low-level lead exposure on human hearing loss. This study was conducted in a steel plant and 412 workers were recruited from all over the plant. Personal information such as demographics and work history was obtained through a questionnaire. All subjects took part in an audiometric examination of hearing thresholds, for both ears, with air-conducted pure tones at frequencies of 500, 1000, 2000, 3000, 4000, 6000 and 8000 Hz. Subjects' blood samples were collected and analyzed for levels of manganese, copper, zinc, arsenic, cadmium and lead with inductive couple plasma-mass spectrometry. Meanwhile, noise levels in different working zones were determined using a sound level meter with A-weighting network. Only subjects with hearing loss difference of no more than 15 dB between both ears and had no congenital abnormalities were included in further data analysis. Lead was the only metal in blood found significantly correlated with hearing loss for most tested sound frequencies (p < 0.05 to p < 0.0001). After adjustment for age and noise level, the logistic regression model analysis indicated that elevated blood lead over 7 {mu}g/dL was significantly associated with hearing loss at the sound frequencies of 3000 through 8000 Hz with odds ratios raging from 3.06 to 6.26 (p < 0.05 {approx} p < 0.005). We concluded that elevated blood lead at level below 10 {mu}g/dL might enhance the noise-induced hearing loss. Future research needs to further explore the detailed mechanism.

  14. Mutations in Cockayne Syndrome-Associated Genes (Csa and Csb) Predispose to Cisplatin-Induced Hearing Loss in Mice

    Science.gov (United States)

    Rainey, Robert N.; Ng, Sum-yan; Llamas, Juan; van der Horst, Gijsbertus T. J.

    2016-01-01

    Cisplatin is a common and effective chemotherapeutic agent, yet it often causes permanent hearing loss as a result of sensory hair cell death. The causes of sensitivity to DNA-damaging agents in nondividing cell populations, such as cochlear hair and supporting cells, are poorly understood, as are the specific DNA repair pathways that protect these cells. Nucleotide excision repair (NER) is a conserved and versatile DNA repair pathway for many DNA-distorting lesions, including cisplatin-DNA adducts. Progressive sensorineural hearing loss is observed in a subset of NER-associated DNA repair disorders including Cockayne syndrome and some forms of xeroderma pigmentosum. We investigated whether either of the two overlapping branches that encompass NER, transcription-coupled repair or global genome repair, which are implicated in Cockayne syndrome and xeroderma pigmentosum group C, respectively, modulates cisplatin-induced hearing loss and cell death in the organ of Corti, the auditory sensory epithelium of mammals. We report that cochlear hair cells and supporting cells in transcription-coupled repair-deficient Cockayne syndrome group A (Csa−/−) and group B (Csb−/−) mice are hypersensitive to cisplatin, in contrast to global genome repair-deficient Xpc−/− mice, both in vitro and in vivo. We show that sensory hair cells in Csa−/− and Csb−/− mice fail to remove cisplatin-DNA adducts efficiently in vitro; and unlike Xpc−/− mice, Csa−/− and Csb−/− mice lose hearing and manifest outer hair cell degeneration after systemic cisplatin treatment. Our results demonstrate that Csa and Csb deficiencies predispose to cisplatin-induced hearing loss and hair/supporting cell damage in the mammalian organ of Corti, and emphasize the importance of transcription-coupled DNA repair in the protection against cisplatin ototoxicity. SIGNIFICANCE STATEMENT The utility of cisplatin in chemotherapy remains limited due to serious side effects, including

  15. ATR confinement leakage determination

    International Nuclear Information System (INIS)

    Kuan, P.; Buescher, B.J.

    1998-01-01

    The air leakage rate from the Advanced Test Reactor (ATR) confinement is an important parameter in estimating hypothesized accidental releases of radiation to the environment. The leakage rate must be determined periodically to assure that the confinement has not degraded with time and such determination is one of the technical safety requirements of ATR operation. This paper reviews the methods of confinement leakage determination and presents an analysis of leakage determination under windy conditions, which can complicate the interpretation of the determined leakage rates. The paper also presents results of analyses of building air exchange under windy conditions. High wind can enhance air exchange and this could increase the release rates of radioisotopes following an accident

  16. Radioactivity leakage monitoring system

    International Nuclear Information System (INIS)

    Nakajima, Takuichiro; Noguchi, Noboru.

    1982-01-01

    Purpose: To obtain a device for detecting the leakage ratio of a primary coolant by utilizing the variation in the radioactivity concentration in a reactor container when the coolant is leaked. Constitution: A measurement signal is produced from a radioactivity measuring instrument, and is continuously input to a malfunction discriminator. The discriminator inputs a measurement signal to a concentration variation discriminator when the malfunction is recognized and simultaneously inputs a measurement starting time from the inputting time to a concentration measuring instrument. On the other hand, reactor water radioactivity concentration data obtained by sampling the primary coolant is input to a concentration variation computing device. A comparator obtains the ratio of the measurement signal from the measuring instrument and the computed data signal from the computing device at the same time and hence the leakage rate, indicates the average leakage rate by averaging the leakage rate signals and also indicates the total leakage amount. (Yoshihara, H.)

  17. Model for Electromagnetic Information Leakage

    OpenAIRE

    Mao Jian; Li Yongmei; Zhang Jiemin; Liu Jinming

    2013-01-01

    Electromagnetic leakage will happen in working information equipments; it could lead to information leakage. In order to discover the nature of information in electromagnetic leakage, this paper combined electromagnetic theory with information theory as an innovative research method. It outlines a systematic model of electromagnetic information leakage, which theoretically describes the process of information leakage, intercept and reproduction based on electromagnetic radiation, and ana...

  18. Noise-induced hearing loss - An examination of the methods of assessment in a cross-sectional study of 87 industrial workers.

    Science.gov (United States)

    Das, S; Mulheran, M; Brewster, M; Banerjee, A R

    2018-04-01

    The surveillance of noise-induced hearing loss (NIHL) according to the Health and Safety Executive (HSE) differs from the medico-legal criteria used to assess NIHL. Our study compares the two systems and proposes a novel method of simplifying the medico-legal criteria and applying it to ascertain noise-induced hearing loss. The anonymised audiograms of a group of 87 industrial workers from a single site were analysed with both methods. The comparison showed approximately one-third of the workers assessed in this study had their noise-induced hearing loss underestimated by the HSE criteria. The majority of these individuals were over 40 years of age. The HSE criteria for noise-induced hearing loss need review and re-alignment with the medico-legal criteria to address the discrepancy between the two systems. © 2017 John Wiley & Sons Ltd.

  19. Effects of noise-induced hearing loss on parvalbumin and perineuronal net expression in the mouse primary auditory cortex.

    Science.gov (United States)

    Nguyen, Anna; Khaleel, Haroun M; Razak, Khaleel A

    2017-07-01

    Noise induced hearing loss is associated with increased excitability in the central auditory system but the cellular correlates of such changes remain to be characterized. Here we tested the hypothesis that noise-induced hearing loss causes deterioration of perineuronal nets (PNNs) in the auditory cortex of mice. PNNs are specialized extracellular matrix components that commonly enwrap cortical parvalbumin (PV) containing GABAergic interneurons. Compared to somatosensory and visual cortex, relatively less is known about PV/PNN expression patterns in the primary auditory cortex (A1). Whether changes to cortical PNNs follow acoustic trauma remains unclear. The first aim of this study was to characterize PV/PNN expression in A1 of adult mice. PNNs increase excitability of PV+ inhibitory neurons and confer protection to these neurons against oxidative stress. Decreased PV/PNN expression may therefore lead to a reduction in cortical inhibition. The second aim of this study was to examine PV/PNN expression in superficial (I-IV) and deep cortical layers (V-VI) following noise trauma. Exposing mice to loud noise caused an increase in hearing threshold that lasted at least 30 days. PV and PNN expression in A1 was analyzed at 1, 10 and 30 days following the exposure. No significant changes were observed in the density of PV+, PNN+, or PV/PNN co-localized cells following hearing loss. However, a significant layer- and cell type-specific decrease in PNN intensity was seen following hearing loss. Some changes were present even at 1 day following noise exposure. Attenuation of PNN may contribute to changes in excitability in cortex following noise trauma. The regulation of PNN may open up a temporal window for altered excitability in the adult brain that is then stabilized at a new and potentially pathological level such as in tinnitus. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. A retrospective analysis of noise-induced hearing loss in the Dutch construction industry

    NARCIS (Netherlands)

    Leensen, M. C. J.; Van Duivenbooden, J. C.; Dreschler, W. A.

    2011-01-01

    Purpose Noise exposure is an important and highly prevalent occupational hazard in the construction industry. This study examines hearing threshold levels of a large population of Dutch construction workers and compares their hearing thresholds to those predicted by ISO-1999. Methods In this

  1. The protective effect of melanocortins on cisplatin-induced hearing loss

    NARCIS (Netherlands)

    Wolters, Francisca Louisa Carolina

    2003-01-01

    Cisplatin is widely used for the treatment of a variety of tumors. Unfortunately, the therapeutic effect of cisplatin is limited because patients can develop a high frequency hearing loss in both ears. Recovery of this hearing loss is observed sporadically. Animal studies have shown that chronic

  2. Preventive effect of curcumin and its highly bioavailable preparation on hearing loss induced by single or repeated exposure to noise: A comparative and mechanistic study

    Directory of Open Access Journals (Sweden)

    Taro Yamaguchi

    2017-08-01

    Full Text Available We sought to determine the preventive effects of curcumin and its highly bioavailable preparation on noise-induced hearing loss in a novel murine model of permanent hearing loss developed by repeated exposure to noise. Upon exposure to noise (8-kHz octave band noise, 90 dB sound pressure level, 1 h, hearing ability was impaired in a temporary and reversible manner. During repeated noise exposure (1-h exposure per day, 5 days, there was a progressive increase in the auditory threshold shift at 12 and 20 kHz. The threshold shift persisted for at least 6 days after noise exposure. Oral administration of curcumin for 3 days before and each day during noise exposure significantly alleviated the hearing loss induced by repeated noise exposure. Curcumin abolished intranuclear translocation of nuclear factor-κB-p65 and generation of 4-hydroxynonenal-adducted proteins found in the cochlea after noise exposure. Theracurmin®, a highly absorbable and bioavailable preparation of curcumin, had strong preventive effects on hearing loss induced by repeated noise exposure. Together, these data suggest that curcumin exerts a preventive effect on noise-induced hearing loss and is therefore a good therapeutic candidate for preventing sensorineural hearing loss.

  3. Preventive effect of curcumin and its highly bioavailable preparation on hearing loss induced by single or repeated exposure to noise: A comparative and mechanistic study.

    Science.gov (United States)

    Yamaguchi, Taro; Yoneyama, Masanori; Onaka, Yusuke; Imaizumi, Atsushi; Ogita, Kiyokazu

    2017-08-01

    We sought to determine the preventive effects of curcumin and its highly bioavailable preparation on noise-induced hearing loss in a novel murine model of permanent hearing loss developed by repeated exposure to noise. Upon exposure to noise (8-kHz octave band noise, 90 dB sound pressure level, 1 h), hearing ability was impaired in a temporary and reversible manner. During repeated noise exposure (1-h exposure per day, 5 days), there was a progressive increase in the auditory threshold shift at 12 and 20 kHz. The threshold shift persisted for at least 6 days after noise exposure. Oral administration of curcumin for 3 days before and each day during noise exposure significantly alleviated the hearing loss induced by repeated noise exposure. Curcumin abolished intranuclear translocation of nuclear factor-κB-p65 and generation of 4-hydroxynonenal-adducted proteins found in the cochlea after noise exposure. Theracurmin ® , a highly absorbable and bioavailable preparation of curcumin, had strong preventive effects on hearing loss induced by repeated noise exposure. Together, these data suggest that curcumin exerts a preventive effect on noise-induced hearing loss and is therefore a good therapeutic candidate for preventing sensorineural hearing loss. Copyright © 2017 The Authors. Production and hosting by Elsevier B.V. All rights reserved.

  4. Raynaud′s phenomenon among men and women with noise-induced hearing loss in relation to vibration exposure

    Directory of Open Access Journals (Sweden)

    Hans Pettersson

    2014-01-01

    Full Text Available Raynaud′s phenomenon is characterized by constriction in blood supply to the fingers causing finger blanching, of white fingers (WF and is triggered by cold. Earlier studies found that workers using vibrating hand-held tools and who had vibration-induced white fingers (VWF had an increased risk for hearing loss compared with workers without VWF. This study examined the occurrence of Raynaud′s phenomenon among men and women with noise-induced hearing loss in relation to vibration exposure. All 342 participants had a confirmed noise-induced hearing loss medico legally accepted as work-related by AFA Insurance. Each subject answered a questionnaire concerning their health status and the kinds of exposures they had at the time when their hearing loss was first discovered. The questionnaire covered types of exposures, discomforts in the hands or fingers, diseases and medications affecting the blood circulation, the use of alcohol and tobacco and for women, the use of hormones and whether they had been pregnant. The participation rate was 41% (n = 133 with 38% (n = 94 for men and 50% (n = 39 for women. 84 men and 36 women specified if they had Raynaud′s phenomenon and also if they had used hand-held vibrating machines. Nearly 41% of them had used hand-held vibrating machines and 18% had used vibrating machines at least 2 h each workday. There were 23 men/6 women with Raynaud′s phenomenon. 37% reported WF among those participants who were exposed to hand-arm vibration (HAV and 15% among those not exposed to HAV. Among the participants with hearing loss with daily use of vibrating hand-held tools more than twice as many reports WF compared with participants that did not use vibrating hand-held tools. This could be interpreted as Raynaud′s phenomenon could be associated with an increased risk for noise-induced hearing loss. However, the low participation rate limits the generalization of the results from this study.

  5. Effects of trap-assisted tunneling on gate-induced drain leakage in silicon-germanium channel p-type FET for scaled supply voltages

    Science.gov (United States)

    Tiwari, Vishal A.; Divakaruni, Rama; Hook, Terence B.; Nair, Deleep R.

    2016-04-01

    Silicon-germanium is considered as an alternative channel material to silicon p-type FET (pFET) for the development of energy efficient high performance transistors for 28 nm and beyond in a high-k metal gate technology because of its lower threshold voltage and higher mobility. However, gate-induced drain leakage (GIDL) is a concern for high threshold voltage device design because of tunneling at reduced bandgap. In this work, the trap-assisted tunneling and band-to-band tunneling (BTBT) effects on GIDL is analyzed and modeled for SiGe pFETs. Experimental results and Monte Carlo simulation results reveal that the pre-halo germanium pre-amorphization implant used to contain the short channel effects contribute to GIDL at the drain sidewall in addition to GIDL due to BTBT in SiGe devices. The results are validated by comparing the experimental observations with the numerical simulation and a set of calibrated models are used to describe the GIDL mechanisms for various drain and gate bias.

  6. Dual modal ultra-bright nanodots with aggregation-induced emission and gadolinium-chelation for vascular integrity and leakage detection.

    Science.gov (United States)

    Feng, Guangxue; Li, Jackson Liang Yao; Claser, Carla; Balachander, Akhila; Tan, Yingrou; Goh, Chi Ching; Kwok, Immanuel Weng Han; Rénia, Laurent; Tang, Ben Zhong; Ng, Lai Guan; Liu, Bin

    2018-01-01

    The study of blood brain barrier (BBB) functions is important for neurological disorder research. However, the lack of suitable tools and methods has hampered the progress of this field. Herein, we present a hybrid nanodot strategy, termed AIE-Gd dots, comprising of a fluorogen with aggregation-induced emission (AIE) characteristics as the core to provide bright and stable fluorescence for optical imaging, and gadolinium (Gd) for accurate quantification of vascular leakage via inductively-coupled plasma mass spectrometry (ICP-MS). In this report, we demonstrate that AIE-Gd dots enable direct visualization of brain vascular networks under resting condition, and that they form localized punctate aggregates and accumulate in the brain tissue during experimental cerebral malaria, indicative of hemorrhage and BBB malfunction. With its superior detection sensitivity and multimodality, we hereby propose that AIE-Gd dots can serve as a better alternative to Evans blue for visualization and quantification of changes in brain barrier functions. Copyright © 2017. Published by Elsevier Ltd.

  7. Leakage Current Induced by Energetic Disorder in Organic Bulk Heterojunction Solar Cells: Comprehending the Ultrahigh Loss of Open-Circuit Voltage at Low Temperatures

    Science.gov (United States)

    Yang, Wenchao; Luo, Yongsong; Guo, Pengfei; Sun, Haibin; Yao, Yao

    2017-04-01

    The open-circuit voltage (Voc ) of organic solar cells generally approaches its maximum obtainable values as the temperature decreases. However, recent experiments have revealed that the Voc may suffer from an ultrahigh loss at low temperatures. In order to verify this explanation and investigate the impacts of energetic disorder on the temperature-dependent behaviors of the Voc in general, we calculate the Voc-T plots with the drift-diffusion method under various device working parameters. With the disorder being incorporated into the device model by considering the disorder-suppressed (temperature-dependent) charge-carrier mobilities, it is found that the ultrahigh Voc losses cannot be reproduced under the Onsager-Braun-type charge generation rate. With the charge generation rate being constant or weakly dependent on temperature, for nonselective contacts, the Voc reduces drastically at low temperatures, while for selective contacts, the Voc increases monotonically with decreasing temperature. With higher carrier mobilities or smaller device thicknesses, the ultrahigh loss occurs at lower temperatures. The mechanism is that, since the disorder-suppressed charge mobilities give rise to both low charge-extraction efficiency and small bimolecular recombination rate, plenty of charge carriers can be extracted from the wrong electrode and can form a large leakage current, which counteracts the majority-carrier current and reduces the Voc at low temperatures. Our results thus highlight the essential role of charge-carrier kinetics, except for the charge-filling effect, on dominating the disorder-induced Voc losses.

  8. Low voltage stress-induced leakage current and traps in ultrathin oxide (1.2 2.5 nm) after constant voltage stresses

    Science.gov (United States)

    Petit, C.; Zander, D.

    2007-10-01

    It has been shown that the low voltage gate current in ultrathin oxide metal-oxide-semiconductor devices is very sensitive to electrical stresses. Therefore, it can be used as a reliability monitor when the oxide thickness becomes too small for traditional electrical measurements to be used. In this work, we present a study on n-MOSCAP devices at negative gate bias in the direct tunneling (DT) regime. If the low voltage stress-induced leakage current (LVSILC) depends strongly on the low sense voltages, it also depends strongly on the stress voltage magnitude. We show that two LVSILC peaks appear as a function of the sense voltage in the LVSILC region and that their magnitude, one compared to the other, depends strongly on the stress voltage magnitude. One is larger than the other at low stress voltage and smaller at high stress voltage. From our experimental results, different conduction mechanisms are analyzed. To explain LVSILC variations, we propose a model of the conduction through the ultrathin gate oxide based on two distinctly different trap-assisted tunneling mechanisms: inelastic of gate electron (INE) and trap-assisted electron (ETAT).

  9. Coding deficits in noise-induced hidden hearing loss may stem from incomplete repair of ribbon synapses in the cochlea

    Directory of Open Access Journals (Sweden)

    Lijuan eShi

    2016-05-01

    Full Text Available Recent evidence has shown that noise-induced damage to the synapse between inner hair cells (IHCs and type I afferent auditory nerve fibers (ANFs may occur in the absence of permanent threshold shift (PTS, and that synapses connecting IHCs with low spontaneous rate (SR ANFs are disproportionately affected. Due to the functional importance of low-SR ANF units for temporal processing and signal coding in noisy backgrounds, deficits in cochlear coding associated with noise-induced damage may result in significant difficulties with temporal processing and hearing in noise (i.e., hidden hearing loss. However, significant noise-induced coding deficits have not been reported at the single unit level following the loss of low-SR units. We have found evidence to suggest that some aspects of neural coding are not significantly changed with the initial loss of low-SR ANFs, and that further coding deficits arise in association with the subsequent reestablishment of the synapses. This suggests that synaptopathy in hidden hearing loss may be the result of insufficient repair of disrupted synapses, and not simply due to the loss of low-SR units. These coding deficits include decreases in driven spike rate for intensity coding as well as several aspects of temporal coding: spike latency, peak-to-sustained spike ratio and the recovery of spike rate as a function of click-interval.

  10. [Protective effect of indirect activator of calcium pump on noise-induced hearing loss].

    Science.gov (United States)

    Liu, Jun; Yu, Ning; Han, Dongyi; Yang, Weiyan; Li, Xingqi

    2002-12-01

    To investigate the possible protective effect of phorbol-12-myristate-13-acetate (PMA), an activator of protein kinase C (PKC) and indirect activator of Ca2+ pump, on noise-induced hearing loss (NIHL). Twenty guinea pigs were divided randomly into two groups, and then perfused with artificial perilymph solutions in one group and with artificial perilymph solutions containing 3 mumol/L PMA in the other one, respectively. All animals were exposed with 100 dB SPL white noise for 2 hours. Cochlear microphonics (CM) and compound action potential (CAP) were recorded from the round window (RW) before noise exposure and 2 hours after noise exposure. There was no significant difference in CAP threshold and CM amplitude between two groups before noise exposure. A significant difference was observed in CAP threshold and CM amplitude between two groups after noise exposure. The amplitude of CM decreased and the threshold of CAP increased in both group after noise exposure, but in the PMA group the decrease of the amplitude of CM was higher while the increase of threshold of CAP lower than that in control (P < 0.05). PMA might have partly protective effect on NIHL. These findings indirectly proved that intracellular Ca2+ overload might involve in the mechanism of NIHL.

  11. Noise-induced hearing loss and associated factors among vector control workers in a Malaysian state.

    Science.gov (United States)

    Masilamani, Retneswari; Rasib, Abdul; Darus, Azlan; Ting, Anselm Su

    2014-11-01

    This study aims to determine the prevalence and associated factors of noise-induced hearing loss (NIHL) among vector control workers in the state of Negeri Sembilan, Malaysia. This was an analytical cross-sectional study conducted on 181 vector control workers who were working in district health offices in a state in Malaysia. Data were collected using a self-administered questionnaire and audiometry. Prevalence of NIHL was 26% among this group of workers. NIHL was significantly associated with the age-group of 40 years and older, length of service of 10 or more years, current occupational noise exposure, listening to loud music, history of firearms use, and history of mumps/measles infection. Following logistic regression, age of more than 40 years and noise exposure in current occupation were associated with NIHL with an odds ratio of 3.45 (95% confidence interval = 1.68-7.07) and 6.87 (95% confidence interval = 1.54-30.69), respectively, among this group of vector control workers. © 2012 APJPH.

  12. Correlation between stress-induced leakage current and dielectric degradation in ultra-porous SiOCH low-k materials

    Energy Technology Data Exchange (ETDEWEB)

    Wu, C., E-mail: Chen.Wu@imec.be; De Wolf, I. [imec, Kapeldreef 75, 3001 Leuven (Belgium); Department of Materials Engineering, KU Leuven, 3000 Leuven (Belgium); Li, Y.; Leśniewska, A.; Varela Pedreira, O.; Marneffe, J.-F. de; Ciofi, I.; Verdonck, P.; Baklanov, M. R.; Bömmels, J.; Tőkei, Zs.; Croes, K. [imec, Kapeldreef 75, 3001 Leuven (Belgium)

    2015-10-28

    Stress-Induced Leakage Current (SILC) behavior during the dielectric degradation of ultra-porous SiOCH low-k materials was investigated. Under high voltage stress, SILC increases to a critical value before final hard breakdown. This SILC increase rate is mainly driven by the injected charges and is negligibly influenced by temperature and voltage. SILC is found to be transient and shows a t{sup −1} relaxation behavior, where t is the storage time at low voltages. This t{sup −1} transient behavior, described by the tunneling front model, is caused by both electron charging of neutral defects in the dielectric close to the cathode interface and discharging of donor defects close to the anode interface. These defects have a uniform density distribution within the probed depth range, which is confirmed by the observed flat band voltage shift results collected during the low voltage storage. By applying an additional discharging step after the low voltage storage, the trap energies and spatial distributions are derived. In a highly degraded low-k dielectric, the majority of defects have a trap depth between 3.4 eV and 3.6 eV and a density level of 1 × 10{sup 18 }eV{sup −1 }cm{sup −3}. The relation between the defect density N and the total amount of the injected charges Q is measured to be sub-linear, N ∼ Q{sup 0.45±0.07}. The physical nature of these stress-induced defects is suggested to be caused by the degradation of the Si-O based skeleton in the low-k dielectric.

  13. Interventions to prevent occupational noise-induced hearing loss: A Cochrane systematic review

    Science.gov (United States)

    Verbeek, Jos H.; Kateman, Erik; Morata, Thais C.; Dreschler, Wouter A.; Mischke, Christina

    2015-01-01

    Objective To assess the effectiveness of interventions for preventing occupational noise exposure or hearing loss compared to no intervention or alternative interventions. Design We searched biomedical databases up to 25 January 2012 for randomized controlled trials (RCT), controlled before-after studies and interrupted time-series of hearing loss prevention among workers exposed to noise. Study sample We included 19 studies with 82 794 participants evaluating effects of hearing loss prevention programs (HLPP). The overall quality of studies was low to very low, as rated using the GRADE approach. Results One study of stricter legislation showed a favorable effect on noise levels. Three studies, of which two RCTs, did not find an effect of a HLPP. Four studies showed that better use of hearing protection devices in HLPPs decreased the risk of hearing loss. In four other studies, workers in a HLPP still had a 0.5 dB greater hearing loss at 4 kHz (95% CI – 0.5 to 1.7) than non-exposed workers. In two similar studies there was a substantial risk of hearing loss in spite of a HLPP. Conclusions Stricter enforcement of legislation and better implementation of HLPPs can reduce noise levels in workplaces. Better evaluations of technical interventions and long-term effects are needed. PMID:24564697

  14. Interventions to prevent occupational noise-induced hearing loss: a Cochrane systematic review.

    Science.gov (United States)

    Verbeek, Jos H; Kateman, Erik; Morata, Thais C; Dreschler, Wouter A; Mischke, Christina

    2014-03-01

    To assess the effectiveness of interventions for preventing occupational noise exposure or hearing loss compared to no intervention or alternative interventions. We searched biomedical databases up to 25 January 2012 for randomized controlled trials (RCT), controlled before-after studies and interrupted time-series of hearing loss prevention among workers exposed to noise. We included 19 studies with 82 794 participants evaluating effects of hearing loss prevention programs (HLPP). The overall quality of studies was low to very low, as rated using the GRADE approach. One study of stricter legislation showed a favorable effect on noise levels. Three studies, of which two RCTs, did not find an effect of a HLPP. Four studies showed that better use of hearing protection devices in HLPPs decreased the risk of hearing loss. In four other studies, workers in a HLPP still had a 0.5 dB greater hearing loss at 4 kHz (95% CI - 0.5 to 1.7) than non-exposed workers. In two similar studies there was a substantial risk of hearing loss in spite of a HLPP. Stricter enforcement of legislation and better implementation of HLPPs can reduce noise levels in workplaces. Better evaluations of technical interventions and long-term effects are needed.

  15. [Association between variations in protocadherin 15 gene and occupational noise-induced hearing loss].

    Science.gov (United States)

    Xu, X R; Yang, Q Y; Jiao, J; Zheng, Y X; He, L H; Yu, S F; Gu, G Z; Chen, G S; Zhou, W H; Wu, H; Li, Y H; Zhang, H L; Zhang, Z R

    2017-01-06

    Objective: The aim of this study was to investigate whether genetic variability in the protocadherin 15 (PCDH15) gene may correspond with increased susceptibility to noise-induced hearing loss (NIHL) in a Chinese population. Methods: A nested case-control study was performed that followed a cohort of 7 445 noise-exposed workers in a steel factory of Henan province in China from January 1, 2006 to December 31, 2015. In this study, 394 cases who had an average hearing threshold of more than 40 dB (A) in high frequency were defined as the case group, and 721 controls who had an average hearing threshold of less than 35 dB (A) in high frequency and less than 25 dB (A) in speech frequency were defined as the control group. A questionnaire was completed by participants and a physical test was also conducted. SNP genotyping was performed using the SNPscan TM Kit. Multivariate unconditional logistic regression additive models were used to analyze the genotypes in different groups, and the association with NIHL. Unconditional logistic regression models were used to assess the associations between the genotypes and NIHL. Results: The average age of study participants was (40.5±8.3) years and the median number of noise-exposed working years M ( P 25 , P 75 ) was 21.1 (9.1, 27.3). The range of noise exposed levels and the levels of cumulative noise exposure (CNE) were 80.1- 98.8 dB(A) and 86.6- 111.2 dB(A), respectively. Only the distribution of the genotypes (TT/CC/CT) of rs11004085 in the PCDH15 gene showed a significant difference between the case and control groups ( P= 0.049). In the case group, the distribution was 370 (93.9%), 24 (6.1%) and 0; in the control group, the distribution was 694 (96.3%), 23 (3.2%) and 1 (0.1% ). After smoking, drinking, hypertension, height and CNE adjustment, compared with the TT genotype individuals with the CC/CT genotype had a 1.90-fold increased risk of NIHL (95% CI: 1.06- 3.40). After stratified these data by the noise exposure level

  16. Universal leakage elimination

    International Nuclear Information System (INIS)

    Byrd, Mark S.; Lidar, Daniel A.; Wu, L.-A.; Zanardi, Paolo

    2005-01-01

    'Leakage' errors are particularly serious errors which couple states within a code subspace to states outside of that subspace, thus destroying the error protection benefit afforded by an encoded state. We generalize an earlier method for producing leakage elimination decoupling operations and examine the effects of the leakage eliminating operations on decoherence-free or noiseless subsystems which encode one logical, or protected qubit into three or four qubits. We find that by eliminating a large class of leakage errors, under some circumstances, we can create the conditions for a decoherence-free evolution. In other cases we identify a combined decoherence-free and quantum error correcting code which could eliminate errors in solid-state qubits with anisotropic exchange interaction Hamiltonians and enable universal quantum computing with only these interactions

  17. PREVALENCE OF NOISE-INDUCED HEARING LOSS POLICE PERSONNEL COMING FOR HEALTH CHECKUP AT GOVERNMENT THENI MEDICAL COLLEGE AND HOSPITALS

    Directory of Open Access Journals (Sweden)

    Indra Thirugnanam

    2017-08-01

    Full Text Available BACKGROUND Occupational settings and transport is the prominent sources of noise that affect health. Noise-Induced Hearing Loss (NIHL is sensory neural hearing loss due to exposure to intense impulse or continuous sound. Exposure to noise can be occupational or non-occupational. The audiologic profile of NIHL is the presence of sensorineural hearing loss that is most pronounced in the high-frequency region between 3,000 Hz and 6,000 Hz of the audiogram and the greatest amount of hearing loss is typically around the 4,000-Hz region (i.e. 4,000 Hz dip.1 The main causes of hearing loss resulting in deafness in adults in India are excessive noise, age and ear infection. Although, occupational hearing loss is a well-recognized occupational condition arising from industries or occupations with exposure to high noise levels (e.g., airline crew,2 it has not been fully evaluated in occupations where the risk is not so overt such as the police force. Police officers are potentially exposed to multiple sources of noise including vehicle horns, gunfire, barking from police dog and traffic noise.3 The aim of the study is to study the incidence of noise-induced hearing loss amongst traffic police personnel who came for master health checkup. MATERIALS AND METHODS A total of 812 constables were examined. All individuals underwent a complete general, systemic and ENT examination to detect any obvious pathology, which may result in hearing loss. A detailed history was taken regarding the number of years of service in traffic branch, place of duty, past history of ear disease or intake of ototoxic drugs. Subjects suffering from preexisting ear disease such as CSO, OME, otosclerosis and suffering from URI has been excluded. Policemen suffering from hypertension and diabetes were also excluded. Remaining 774 was included in the study. This study was approved by the institutional ethical committee, Government Theni Medical College. Written consent was obtained from

  18. Coolant leakage detecting device

    International Nuclear Information System (INIS)

    Yamauchi, Kiyoshi; Kawai, Katsunori; Ishihara, Yoshinao.

    1995-01-01

    The device of the present invention judges an amount of leakage of primary coolants of a PWR power plant at high speed. Namely, a mass of coolants contained in a pressurizer, a volume controlling tank and loop regions is obtained based on a preset relational formula and signals of each of process amount, summed up to determine the total mass of coolants for every period of time. The amount of leakage for every period of time is calculated by a formula of Karman's filter based on the total mass of the primary coolants for every predetermined period of time, and displays it on CRT. The Karman's filter is formed on every formula for several kinds of states formed based on the preset amount of the leakage, to calculate forecasting values for every mass of coolants. An adaptable probability for every preset leakage amount is determined based on the difference between the forecast value and the observed value and the scattering thereof. The adaptable probability is compared with a predetermined threshold value, which is displayed on the CRT. This device enables earlier detection of leakage and identification of minute leakage amount as compared with the prior device. (I.S.)

  19. Study on the annular leakage-flow-induced vibrations. 1st Report. Stability for translational and rotational single-degree-of-freedom systems; Kanjo sukimaryu reiki shindo ni kansuru kenkyu. 1. Heishin oyobi kaiten 1 jiyudokei no anteise

    Energy Technology Data Exchange (ETDEWEB)

    Li, D.W. [Hitachi, Ltd., Tokyo (Japan); Kaneko, S. [The University of Tokyo, Tokyo (Japan); Hayama, S. [Toyama Prefectural University, Toyama (Japan)

    1999-07-25

    This study reports the stability of annular leakage-flow-induced vibrations. The pressure distribution of fluid between a fixed outer cylinder and a vibrating inner cylinder was obtained in the case of a translationally and rotationally coupled motion of the inner cylinder. The unsteady fluid force acting on the inner cylinder in the case of translational and rotational single-degree-of-freedom vibrations was then expressed in terms proportional to the acceleration, velocity, and displacement. Then the critical flow rate (at which stability was lost) was determined for an annular leakage-flow-induced vibration. Finally, the stability was investigated theoretically. It is known that instability will occur in the case of a divergent passage, but the critical flow rate depends on the passage increment in a limited range: the eccentricity of the passage and the pressure loss factor at the inlet of the passage lower the stability. (author)

  20. A study of the possibility of acquiring noise-induced hearing loss by the use of personal cassette players (walkman).

    Science.gov (United States)

    Turunen-Rise, I; Flottorp, G; Tvete, O

    1991-01-01

    Playing various types of music on five selected personal cassette players (PCPs), A-weighted sound pressure levels (SPLs), together with octave band spectrum, were measured on KEMAR (Knowles Electronics Manikin for Acoustic Research). Maximum and equivalent SPLs were measured for various types of music, PCPs and for different gain (volume) settings. The measured SPL-values on KEMAR ear were transformed to field values outside the ear canal by means of corrections based on KEMAR's ear canal resonance curve--in order to compare measured values with the Norwegian national noise risk criteria. Temporary threshold shift (TTS) was measured after listening to PCP music for one hour in order to obtain additional information about possible risk of hearing damage. TTS values are presented for six subjects when playing two different pop music cassettes on one type PCP. Our analysis indicates that the risk for permanent noise-induced hearing loss from listening to PCP is very small for normal listening conditions.

  1. Radiotherapy-induced hearing loss in patients with laryngeal and hypopharyngeal carcinomas.

    Science.gov (United States)

    Gudelj, Goran; Trotić, Robert; Herceg, Tonko; Parazajder, Domagoj; Vagić, Davor; Geber, Goran

    2014-09-01

    The purpose of this study was to investigate a hypothesized correlation of development of a sensorineural hearing loss and radiotherapy in patients with laryngeal and hypopharyngeal carcinoma. This prospective study included a total of 50 patients, which after strict exclusion critera (audiologic problems before RT primary tumors of the auditory system, spread of the primary tumor to any part of the auditory system) resulted in 23 analyzed patients, ranging between 50 and 76 years of age, with a mean age of 60. Audiometry measuring frequency-specific thresholds was performed in three time points: one month before radiotherapy, one and six months after radiotherapy. A significant statistical difference in hearing tresholds after radiotherapy was found in 6 out of 23 patients. An obvious tendency towards hearing loss without statistical significance at 250 and 4000 Hz was found for a whole tested population (p < or = 0.3 with Bonferroni correction). Observed tendency towards hearing loss after radiotherapy of laryngeal carcinoma was related to side of the tumor and less severe when chemotherapy was not added as adjuvant therapy. These results should help to decrease a rate of hearing loss by careful planing of ear protection, by using observed frequencies as relevant markers of hearing loss and by reconsidering adjuvant chemoterapy during radiotherapy of laryngeal carcinoma.

  2. Genetic background of Prop1(df) mutants provides remarkable protection against hypothyroidism-induced hearing impairment.

    Science.gov (United States)

    Fang, Qing; Giordimaina, Alicia M; Dolan, David F; Camper, Sally A; Mustapha, Mirna

    2012-04-01

    Hypothyroidism is a cause of genetic and environmentally induced deafness. The sensitivity of cochlear development and function to thyroid hormone (TH) mandates understanding TH action in this sensory organ. Prop1(df) and Pou1f1(dw) mutant mice carry mutations in different pituitary transcription factors, each resulting in pituitary thyrotropin deficiency. Despite the same lack of detectable serum TH, these mutants have very different hearing abilities: Prop1(df) mutants are mildly affected, while Pou1f1(dw) mutants are completely deaf. Genetic studies show that this difference is attributable to the genetic backgrounds. Using embryo transfer, we discovered that factors intrinsic to the fetus are the major contributor to this difference, not maternal effects. We analyzed Prop1(df) mutants to identify processes in cochlear development that are disrupted in other hypothyroid animal models but protected in Prop1(df) mutants by the genetic background. The development of outer hair cell (OHC) function is delayed, but Prestin and KCNQ4 immunostaining appear normal in mature Prop1(df) mutants. The endocochlear potential and KCNJ10 immunostaining in the stria vascularis are indistinguishable from wild type, and no differences in neurofilament or synaptophysin staining are evident in Prop1(df) mutants. The synaptic vesicle protein otoferlin normally shifts expression from OHC to IHC as temporary afferent fibers beneath the OHC regress postnatally. Prop1(df) mutants exhibit persistent, abnormal expression of otoferlin in apical OHC, suggesting delayed maturation of synaptic function. Thus, the genetic background of Prop1(df) mutants is remarkably protective for most functions affected in other hypothyroid mice. The Prop1(df) mutant is an attractive model for identifying the genes that protect against deafness.

  3. Experimental evaluation of clinical colon anastomotic leakage.

    Science.gov (United States)

    Pommergaard, Hans-Christian

    2014-03-01

    Colorectal anastomotic leakage remains a frequent and serious complication in gastrointestinal surgery. Patient and procedure related risk factors for anastomotic leakage have been identified. However, the responsible pathophysiological mechanisms are still unknown. Among these, ischemia and insufficient surgical technique have been suggested to play a central role. Animal models are valuable means to evaluate pathophysiological mechanisms and may be used to test preventive measures aiming at reducing the risk of anastomotic leakage, such as external anastomotic coating. The aim of this thesis was to: Clarify the best suited animal to model clinical anastomotic leakage in humans; Create animal models mimicking anastomotic leakage in humans induced by insufficient surgical technique and tissue ischemia; Determine the best suited coating materials to prevent anastomotic leakage. This study is a systematic review using the databases MEDLINE and Rex. MEDLINE was searched up to October 2010 to identify studies on experimental animal models of clinical colon anastomotic leakage. From the Rex database, textbooks on surgical aspects as well as gastrointestinal physiology and anatomy of experimental animals were identified. The results indicated that the mouse and the pig are the best suited animals to evaluate clinical anastomotic leakage. However, the pig model is less validated and more costly to use compared with the mouse. Most frequently, rats are used as models. However, extreme interventions are needed to create clinical leakage in these animals. The knowledge from this study formed the basis for selecting the animal species most suited for the models in the next studies. STUDY 2: In this experimental study, technically insufficient colonic anastomoses were performed in 110 C57BL/6 mice. The number of sutures in the intervention group was reduced to produce a suitable leakage rate. Moreover, the analgesia and suture material were changed in order to optimize the

  4. Identification of induced and naturally occurring conductive hearing loss in mice using bone conduction.

    Science.gov (United States)

    Chhan, David; McKinnon, Melissa L; Rosowski, John J

    2017-03-01

    While many mouse models of hearing loss have been described, a significant fraction of the genetic defects in these models affect both the inner ear and middle ears. A common method used to separate inner-ear (sensory-neural) from middle-ear (conductive) pathologies in the hearing clinic is the combination of air-conduction and bone-conduction audiometry. In this report, we investigate the use of air- and bone-conducted evoked auditory brainstem responses to perform a similar separation in mice. We describe a technique by which we stimulate the mouse ear both acoustically and via whole-head vibration. We investigate the sensitivity of this technique to conductive hearing loss by introducing middle-ear lesions in normal hearing mice. We also use the technique to investigate the presence of an age-related conductive hearing loss in a common mouse model of presbycusis, the BALB/c mouse. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Pure tone audiograms and possible aminoglycoside-induced hearing loss in belugas (Delphinapterus leucas)

    Science.gov (United States)

    Finneran, James J.; Carder, Donald A.; Dear, Randall; Belting, Traci; McBain, Jim; Dalton, Les; Ridgway, Sam H.

    2005-06-01

    A behavioral response paradigm was used to measure pure-tone hearing sensitivities in two belugas (Delphinapterus leucas). Tests were conducted over a 20-month period at the Point Defiance Zoo and Aquarium, in Tacoma, WA. Subjects were two males, aged 8-10 and 9-11 during the course of the study. Subjects were born in an oceanarium and had been housed together for all of their lives. Hearing thresholds were measured using a modified up/down staircase procedure and acoustic response paradigm where subjects were trained to produce audible responses to test tones and to remain quiet otherwise. Test frequencies ranged from approximately 2 to 130 kHz. Best sensitivities ranged from approximately 40 to 50 dB re 1 μPa at 50-80 kHz and 30-35 kHz for the two subjects. Although both subjects possessed traditional ``U-shaped'' mammalian audiograms, one subject exhibited significant high-frequency hearing loss above 37 kHz compared to previously published data for belugas. Hearing loss in this subject was estimated to approach 90 dB for frequencies above 50 kHz. Similar ages, ancestry, and environmental conditions between subjects, but a history of ototoxic drug administration in only one subject, suggest that the observed hearing loss was a result of the aminoglycoside antibiotic amikacin. .

  6. Loss of Myh14 Increases Susceptibility to Noise-Induced Hearing Loss in CBA/CaJ Mice

    Directory of Open Access Journals (Sweden)

    Xiaolong Fu

    2016-01-01

    Full Text Available MYH14 is a member of the myosin family, which has been implicated in many motile processes such as ion-channel gating, organelle translocation, and the cytoskeleton rearrangement. Mutations in MYH14 lead to a DFNA4-type hearing impairment. Further evidence also shows that MYH14 is a candidate noise-induced hearing loss (NIHL susceptible gene. However, the specific roles of MYH14 in auditory function and NIHL are not fully understood. In the present study, we used CRISPR/Cas9 technology to establish a Myh14 knockout mice line in CBA/CaJ background (now referred to as Myh14−/− mice and clarify the role of MYH14 in the cochlea and NIHL. We found that Myh14−/− mice did not exhibit significant hearing loss until five months of age. In addition, Myh14−/− mice were more vulnerable to high intensity noise compared to control mice. More significant outer hair cell loss was observed in Myh14−/− mice than in wild type controls after acoustic trauma. Our findings suggest that Myh14 may play a beneficial role in the protection of the cochlea after acoustic overstimulation in CBA/CaJ mice.

  7. Coolant leakage detection device

    International Nuclear Information System (INIS)

    Ito, Takao.

    1983-01-01

    Purpose: To surely detect the coolant leakage at a time when the leakage amount is still low in the intra-reactor inlet pipeway of FBR type reactor. Constitution: Outside of the intra-reactor inlet piping for introducing coolants at low temperature into a reactor core, an outer closure pipe is furnished. The upper end of the outer closure pipe opens above the liquid level of the coolants in the reactor, and a thermocouple is inserted to the opening of the upper end. In such a structure, if the coolants in the in-reactor piping should leak to the outer closure pipe, coolants over-flows from the opening thereof, at which the thermocouple detects the temperature of the coolants at a low temperature, thereby enabling to detect the leakage of the coolants at a time when it is still low. (Kamimura, M.)

  8. Prevalence and risk factors of noise-induced hearing loss among liquefied petroleum gas (LPG) cylinder infusion workers in Taiwan.

    Science.gov (United States)

    Chang, Shu-Ju; Chang, Chin-Kuo

    2009-12-01

    We assessed the exposure levels of noise, estimated prevalence, and identify risk factors of noise-induced hearing loss (NIHL) among male workers with a cross-sectional study in a liquefied petroleum gas cylinder infusion factory in Taipei City. Male in-field workers exposed to noise and administrative controls were enrolled in 2006 and 2007. Face-to-face interviews were applied for demographics, employment history, and drinking/smoking habit. We then performed the measurements on noise levels in field and administration area, and hearing thresholds on study subjects with standard apparatus and protocols. Existence of hearing loss > 25 dBHL for the average of 500 Hz, 1 kHz, and 2 kHz was accordingly determined for NIHL. The effects from noise exposure, predisposing characteristics, employment-related factors, and personal habits to NIHL were estimated by univariate and multivariate logistic regressions. A total of 75 subjects were involved in research and 56.8% of in-field workers had NIHL. Between the in-field and administration groups, hearing thresholds on the worse ear showed significant differences at frequencies of 4 k, 6 k, and 8 kHz with aging considered. Adjusted odds ratio for field noise exposure (OR=99.57, 95% CI: 3.53, 2,808.74) and frequent tea or coffee consumption (OR=0.03, 95% CI: 0.01, 0.51) were found significant. Current study addressed NIHL in a specific industry in Taiwan. Further efforts in minimizing its impact are still in need.

  9. Channel follower leakage restrictor

    International Nuclear Information System (INIS)

    Williamson, H.E.; Smith, B.A.

    1977-01-01

    An improved means is provided to control coolant leakage between the flow channel and the lower tie plate of a nuclear fuel assembly. The means includes an opening in the lower tie plate and a movable element adjacent thereto. The coolant pressure within the tie plate biases the movable means toward the inner surface of the surrounding flow channel to compensate for any movement of the flow channel away from the lower tie plate to thereby control the leakage of coolant flow from the fuel assemblies to the spaces among the fuel assemblies of the core. 9 figures

  10. Noise-induced hearing loss among quarry workers in a north-eastern state of malaysia: a study on knowledge, attitude and practice.

    Science.gov (United States)

    Ismail, Ahmad Filza; Daud, Aziah; Ismail, Zaliha; Abdullah, Baharudin

    2013-09-01

    Noise is known to be one of the environmental and occupational hazards listed in the Factory and Machinery Act 1967. Quarries with loud deafening sounds from trucks and machineries pose the risk of noise-induced hearing loss to workers. This study was designed to assess the knowledge, attitude and practice towards noise-induced hearing loss and to determine the prevalence of noise-induced hearing loss and its associated factors among quarry workers in a north-eastern state of Malaysia. A cross-sectional study was conducted at six quarries in a north-eastern state of Malaysia, with 97 consented respondents who answered a validated version of a questionnaire and underwent pure tone audiogram. The respondents were male, aged between 18 to 50 years, working in the quarry area for at least 6-months duration with no family history of ear diseases. The mean percentage scores of knowledge, attitude and practice were 44 (11), 70 (10) and 28 (16) percent, respectively. The prevalence of noise-induced hearing loss was found to be 57 (95% CI: 47, 67) with 46 (84%) having mild and moderate noise-induced hearing loss, and 34 (62%) involved both ears. Multiple logistic regressions showed that age and practice score were the associated factors with odd ratios of 1.1 (95% CI: 1.1, 1.2; phearing loss was contributed by factors such as poor practice and old age.

  11. Crossmodal plasticity in auditory, visual and multisensory cortical areas following noise-induced hearing loss in adulthood.

    Science.gov (United States)

    Schormans, Ashley L; Typlt, Marei; Allman, Brian L

    2017-01-01

    Complete or partial hearing loss results in an increased responsiveness of neurons in the core auditory cortex of numerous species to visual and/or tactile stimuli (i.e., crossmodal plasticity). At present, however, it remains uncertain how adult-onset partial hearing loss affects higher-order cortical areas that normally integrate audiovisual information. To that end, extracellular electrophysiological recordings were performed under anesthesia in noise-exposed rats two weeks post-exposure (0.8-20 kHz at 120 dB SPL for 2 h) and age-matched controls to characterize the nature and extent of crossmodal plasticity in the dorsal auditory cortex (AuD), an area outside of the auditory core, as well as in the neighboring lateral extrastriate visual cortex (V2L), an area known to contribute to audiovisual processing. Computer-generated auditory (noise burst), visual (light flash) and combined audiovisual stimuli were delivered, and the associated spiking activity was used to determine the response profile of each neuron sampled (i.e., unisensory, subthreshold multisensory or bimodal). In both the AuD cortex and the multisensory zone of the V2L cortex, the maximum firing rates were unchanged following noise exposure, and there was a relative increase in the proportion of neurons responsive to visual stimuli, with a concomitant decrease in the number of neurons that were solely responsive to auditory stimuli despite adjusting the sound intensity to account for each rat's hearing threshold. These neighboring cortical areas differed, however, in how noise-induced hearing loss affected audiovisual processing; the total proportion of multisensory neurons significantly decreased in the V2L cortex (control 38.8 ± 3.3% vs. noise-exposed 27.1 ± 3.4%), and dramatically increased in the AuD cortex (control 23.9 ± 3.3% vs. noise-exposed 49.8 ± 6.1%). Thus, following noise exposure, the cortical area showing the greatest relative degree of multisensory convergence

  12. Assessing Agulhas leakage

    NARCIS (Netherlands)

    van Sebille, E.

    2009-01-01

    Agulhas leakage, the water that flows from the Indian Ocean to the Atlantic Ocean, plays an important role in the circulation of the Atlantic Ocean. The magnitude of this flux of warm and saline Indian Ocean water into the much colder and fresher Atlantic Ocean can be related to the strength of the

  13. Roxby Downs water leakage

    International Nuclear Information System (INIS)

    1996-01-01

    The Environment, Resource and development Committee has been asked by Parliament to examine 'a massive leakage of water at Roxby Downs' and to make recommendations 'as to further action'. It has also been specifically asked to comment on 'the desirability of the Department of Mines and Energy having prime responsibility for environmental matters in relation to mining operations'. This report begins with a description of the Olympic Dam operations near Roxby Downs and with a brief overview of the regulations controlling those operations. The site of the leakage the Olympic Dam tailings retention system is then described in greater detail. Part 3 describes how the system was originally designed, modified and approved. It ends with a series of findings about the adequacy of the original design (including the monitoring systems built into it) and of the approvals process. Recommendations are then made about how future approvals should be handled. Part 4 of the report outlines how the tailings retention system was built and operated and how the massive leakage from it was detected and reported. Findings about the adequacy of the management of the system and about the initial reactions to the leakage are then made, together with recommendations designed to improve future management of the system. 25 refs., 15 figs

  14. Noise‑Induced Hearing Loss Still a Problem in Shipbuilders: A ...

    African Journals Online (AJOL)

    relevant factors implicated in the multi‑factorial aetiology of NIHL (age, duration of .... metal fragments entering the ear was also asked in view of ... Pure tone thresholds for bone ... disease (two with Grade I and one with Grade II hearing loss).

  15. Interventions to prevent occupational noise-induced hearing loss: a Cochrane systematic review

    NARCIS (Netherlands)

    Verbeek, Jos H.; Kateman, Erik; Morata, Thais C.; Dreschler, Wouter A.; Mischke, Christina

    2014-01-01

    To assess the effectiveness of interventions for preventing occupational noise exposure or hearing loss compared to no intervention or alternative interventions. We searched biomedical databases up to 25 January 2012 for randomized controlled trials (RCT), controlled before-after studies and

  16. Compensation claims for occupational noise induced hearing loss between 1998 and 2008: yearly incidence rates and trends in older workers.

    Science.gov (United States)

    Radi, Samia; Benke, Geza; Schaafsma, Frederieke; Sim, Malcolm

    2016-04-01

    To estimate yearly incidence rates for occupational noise induced hearing loss (ONIHL) claims and to describe occupational factors in relation to age for incident cases in Victoria, Australia, between 1998 and 2008. All compensation claims lodged for deafness between 1 July 1998 and 30 June 2008 in the working population covered by the Victorian compensation scheme were analysed. Denominators were provided from 1999-2000 and incidence rates were expressed per 100,000 workers for each financial year. Overall, 81.2% of the 4,518 claims lodged were accepted. Successful claimants were predominantly males (96.5%) and claimants aged 56 to 65 years formed half the overall claims. The number of accepted claims was almost five times higher in 2007-08 than 1998-99. The highest rise was in claimants aged 56 years and above, particularly in those after retirement age. The number of claims and yearly incidence rates (IR) more than doubled over the period (240 claims and IR of 15.1 per 100,000 workers in 1999-2000 versus 669 claims and IR of 34.2 in 2007-08) with a sharp increase from 2004-05 to almost double within one single year and remained at high levels afterwards. The dramatic increase in eligible claims may reflect an increase in awareness of entitlements among workers eligible to make a successful claim. This awareness may be the result of increased opportunities for screening coinciding with changes in regulations. Older workers who worked in smaller workplaces may also be targeted by services providers as they combine occupational noise induced hearing loss (ONIHL) and presbycusis (hearing loss due to age), but this hypothesis needs further evaluation. © 2015 Public Health Association of Australia.

  17. Analysis of plasma microRNA expression profiles in male textile workers with noise-induced hearing loss.

    Science.gov (United States)

    Ding, Lu; Liu, Jing; Shen, Huan-Xi; Pan, Li-Ping; Liu, Qing-Dong; Zhang, Heng-Dong; Han, Lei; Shuai, Li-Guo; Ding, En-Min; Zhao, Qiu-Ni; Wang, Bo-Shen; Zhu, Bao-Li

    2016-03-01

    Circulating microRNAs (miRNAs) have attracted interests as non-invasive biomarkers of physiological and pathological conditions, which may be applied in noise-induced hearing loss (NIHL). However, no epidemiology studies have yet examined the potential effects of NIHL or noise exposure on miRNA expression profiles. We sought to identify permanent NIHL-related miRNAs and to predict the biological functions of the putative genes encoding the indicated miRNAs. In the discovery stage, we used a microarray assay to detect the miRNA expression profiles between pooled plasma samples from 10 noise-exposed individuals with normal hearing and 10 NIHL patients. In addition, we conducted a preliminary validation of six candidate miRNAs in the same 20 workers. Subsequently, three miRNAs were selected for expanded validation in 23 non-exposed individuals with normal hearing and 46 noise-exposed textile workers which including 23 noise-exposed workers with normal hearing and 23 NIHL patients. Moreover, we predicted the biological functions of the putative target genes using a Gene Ontology (GO) function enrichment analysis. In the discovery stage, compared with the noise exposures with normal hearing, 73 miRNAs demonstrated at least a 1.5-fold differential expression in the NIHL patients. In the preliminary validation, compared with the noise exposures, the plasma levels of miR-16-5p, miR-24-3p, miR-185-5p and miR-451a were all upregulated (P < 0.001) in the NIHL patients. In the expanded validation stage, compared with the non-exposures, the plasma levels of miR-24, miR-185-5p and miR-451a were all significantly downregulated (P < 0.001) in the exposures. And compared with the noise exposures, the plasma levels of miR-185-5p and miR-451a were slightly elevated (P < 0.001) in the NIHL patients, which were consistent with the results of preliminary validation and microarray analysis. The two indicated plasma miRNAs may be biomarkers of indicating responses to noise exposure

  18. Comparison of Vestibular Evoked Myogenic Potential and Caloric Tests Findings in Noise Induced Hearing Loss-Affected and Healthy Individuals

    Directory of Open Access Journals (Sweden)

    Farinoosh Fakharnia

    2010-06-01

    Full Text Available Background and Aim: Balance disturbance is one of the non-auditory effects of noisy industrial environments that is usually neglected. The aim of the current study was to investigate the effect of occupational noise on vestibular system among workers with noise-induced hearing loss (NIHL, based on both vestibular evoked myogenic potentials (VEMP and caloric tests.Methods: Thirty male workers with noise-induced hearing loss and thirty male matched controls were examined by VEMP and caloric tests. Study parameters included unilateral weakness, p13 and n23 latencies, and p13-n23 amplitude. Caloric test was performed only for 20 patients.Results: No significant difference was observed in unilateral weakness between the two groups. On the other hand, the difference in mean latencies of p13 in the right ear (p=0.003 and left ear (p=0.01 was significant between the two groups. However, the difference in n23 latency was significant only in the right ear (p=0.03. There was no significant difference between groups in p13-n23 amplitude.Conclusion: It seems that pars inferior of vestibule is the susceptible part in individuals with NIHL. In general, abnormal findings in both VEMP and caloric tests were more common compared to functional symptoms such as vertigo, which may be due to central compensation and the symmetry of the disorder.

  19. Colorectal Anastomotic Leakage: New perspectives

    NARCIS (Netherlands)

    F. Daams (Freek)

    2014-01-01

    markdownabstract__Abstract__ This thesis provides new perspectives on colorectal anastomotic leakages. In both experimental and clinical studies, aspects of prevention, early identification, treatment and consequences of anastomotic leakage are discussed.

  20. [The issue of medico-legal assessment of noise induced hearing loss: comparison of methods].

    Science.gov (United States)

    Bosio, D; Coggiola, M; Baracco, A; Andreis, P; Perrelli, F

    2011-01-01

    Audiogram classification is crucial for hearing protection of workers occupationally exposed to noise. The methods that have been proposed are based on two principles: the morphological evaluation of the audiometric curve (eg. Merluzzi-Pira-Bosio--MPB) or the average hearing loss on different frequencies (eg. Albera-Beatrice--AB). The purpose of this study was to classify audiograms compatible with chronic acoustic trauma performed at the Occupational Medicine Outpatient Clinic of CTO Hospital in Turin from 2004 to 2011 with the methods outlined in Guidelines published by SIMLII. A substantial agreement among the methods was observed. While MPB is the most appropriate method for secondary prevention, the AB would seem more appropriate for the verification of a permanent weakening that has to be reported to the competent legal authorities.

  1. Symposium: Noise-Induced Hearing Loss Held in Beaune, France on 28-30 May 1990.

    Science.gov (United States)

    1991-01-01

    animals were allowed to survive varying embryos . lie found that regenerated organs amounts of th,ie ranging from t day to 32 were numerically similar... embryo persist into adulthood or also produces complete loss of hair cells in any emerge from the damaged epithelium. part of the cochlea. Althotgh the...indices visucis destinis A influencer Iaprocessing computers designe’d for hearing- silection de Ia bande di6coute en activant Iaimpaired persona

  2. Phase 3 Clinical Trials: D-Methionine to Reduce Noise-Induced Hearing Loss

    Science.gov (United States)

    2013-03-01

    tympanometry, and pure-tone hearing threshold testing at .5, 1, 2, 3, 4, 6, 8 kHz bilaterally. Tinnitus will be measured using standardized ...chemistry, and urinalysis ) on all study participants. The purpose of these recommendations were 1) to exclude participants with mild renal impairment until...analysis and urinalysis for the study participants to the study protocol. Therefore, during the third quarter, no additions were made to the original

  3. A PD-SOI based DTI-LOCOS combined cross isolation technique for minimizing TID radiation induced leakage in high density memory

    International Nuclear Information System (INIS)

    Qiao Fengying; Pan Liyang; Wu Dong; Liu Lifang; Xu Jun

    2014-01-01

    In order to minimize leakage current increase under total ionizing dose (TID) radiation in high density memory circuits, a new isolation technique, combining deep trench isolation (DTI) between the wells, local oxidation of silicon (LOCOS) isolation between the devices within the well, and a P-diffused area in order to limit leakage at the isolation edge is implemented in partly-depleted silicon-on-insulator (PD-SOI) technology. This radiation hardening technique can minimize the layout area by more than 60%, and allows flexible placement of the body contact. Radiation hardened transistors and 256 Kb flash memory chips are designed and fabricated in a 0.6 μm PD-SOI process. Experiments show that no obvious increase in leakage current is observed for single transistors under 1 Mrad(Si) radiation, and that the 256 Kb memory chip still functions well after a TID of 100 krad(Si), with only 50% increase of the active power consumption in read mode. (semiconductor devices)

  4. Is Hearing Impairment Associated with Rheumatoid Arthritis?

    DEFF Research Database (Denmark)

    Emamifar, Amir; Bjoerndal, Kristine; Jensen Hansen, Inger Marie

    2016-01-01

    BACKGROUND: Rheumatoid arthritis (RA) is a systemic, inflammatory disease that affects 1% of the population. The auditory system may be involved during the course of disease; however the association of RA and hearing impairment has not been clearly defined. OBJECTIVE: The objective of this review...... is to evaluate published clinical reports related to hearing impairment in patients with RA. Furthermore, we discuss possible pathologies and associated factors as well as new treatment modalities. METHOD: A thorough literature search was performed using available databases including Pubmed, Embase, Cochrane...... and ComDisDome to cover all relative reports. The following keywords were used: hearing loss, hearing difficulties, hearing disorders, hearing impairment, sensorineural hearing loss, conductive hearing loss, mixed hearing loss, autoimmune hearing loss, drug ototoxicity, drug-induced hearing loss, hearing...

  5. Noise-induced and age-related hearing loss:  new perspectives and potential therapies [version 1; referees: 4 approved

    Directory of Open Access Journals (Sweden)

    M Charles Liberman

    2017-06-01

    Full Text Available The classic view of sensorineural hearing loss has been that the primary damage targets are hair cells and that auditory nerve loss is typically secondary to hair cell degeneration. Recent work has challenged that view. In noise-induced hearing loss, exposures causing only reversible threshold shifts (and no hair cell loss nevertheless cause permanent loss of >50% of the synaptic connections between hair cells and the auditory nerve. Similarly, in age-related hearing loss, degeneration of cochlear synapses precedes both hair cell loss and threshold elevation. This primary neural degeneration has remained a “hidden hearing loss” for two reasons: 1 the neuronal cell bodies survive for years despite loss of synaptic connection with hair cells, and 2 the degeneration is selective for auditory nerve fibers with high thresholds. Although not required for threshold detection when quiet, these high-threshold fibers are critical for hearing in noisy environments. Research suggests that primary neural degeneration is an important contributor to the perceptual handicap in sensorineural hearing loss, and it may be key to the generation of tinnitus and other associated perceptual anomalies. In cases where the hair cells survive, neurotrophin therapies can elicit neurite outgrowth from surviving auditory neurons and re-establishment of their peripheral synapses; thus, treatments may be on the horizon.

  6. Hearing Conservation Team

    Data.gov (United States)

    Federal Laboratory Consortium — The Hearing Conservation Team focuses on ways to identify the early stages of noise-induced damage to the human ear.Our current research involves the evaluation of...

  7. Effect of c-myc on the ultrastructural structure of cochleae in guinea pigs with noise induced hearing loss

    International Nuclear Information System (INIS)

    Han, Yu; Zhong, Cuiping; Hong, Liu; Wang, Ye; Qiao, Li; Qiu, Jianhua

    2009-01-01

    Noise over-stimulation may induce hair cells loss and hearing deficit. The c-myc oncogene is a major regulator for cell proliferation, growth, and apoptosis. However, the role of this gene in the mammalian cochlea is still unclear. The study was designed to firstly investigate its function under noise condition, from the aspect of cochlear ultrastructural changes. We had established the adenoviral vector of c-myc gene and delivered the adenovirus suspension into the scala tympani of guinea pigs 4 days before noise exposure. The empty adenoviral vectors were injected as control. Then, all subjects were exposed to 4-kHz octave-band noise at 110 dB SPL for 8 h/day, 3 days consecutively. Auditory thresholds were assessed by auditory brainstem response, prior to and 7 days following noise exposure. On the seventh days after noise exposure, the cochlear sensory epithelia surface was observed microscopically and the cochleae were taken to study the ultrastructural changes. The results indicated that auditory threshold shift after noise exposure was higher in the ears treated with Ad.EGFP than that treated with Ad.c-myc-EGFP. Stereocilia loss and the disarrangement of outer hair cells were observed, with greater changes found in the Ad.EGFP group. Also, the ultrastructure changes were severe in the Ad.EGFP group, but not obvious in the Ad.c-myc-EGFP group. Therefore, c-myc gene might play an unexpected role in hearing functional and morphological protection from acoustic trauma.

  8. Effect of c-myc on the ultrastructural structure of cochleae in guinea pigs with noise induced hearing loss

    Energy Technology Data Exchange (ETDEWEB)

    Han, Yu; Zhong, Cuiping [Department of Otolaryngology, Xijing Hospital, Fourth Military Medical University, Xi' an, 710032 Shaanxi Province (China); Hong, Liu [First Division of Digestive Diseases, Xijing Hospital, Fourth Military Medical University, Xi' an, 710032 Shaanxi Province (China); Wang, Ye; Qiao, Li [Department of Otolaryngology, Xijing Hospital, Fourth Military Medical University, Xi' an, 710032 Shaanxi Province (China); Qiu, Jianhua, E-mail: qiujh@fmmu.edu.cn [Department of Otolaryngology, Xijing Hospital, Fourth Military Medical University, Xi' an, 710032 Shaanxi Province (China)

    2009-12-18

    Noise over-stimulation may induce hair cells loss and hearing deficit. The c-myc oncogene is a major regulator for cell proliferation, growth, and apoptosis. However, the role of this gene in the mammalian cochlea is still unclear. The study was designed to firstly investigate its function under noise condition, from the aspect of cochlear ultrastructural changes. We had established the adenoviral vector of c-myc gene and delivered the adenovirus suspension into the scala tympani of guinea pigs 4 days before noise exposure. The empty adenoviral vectors were injected as control. Then, all subjects were exposed to 4-kHz octave-band noise at 110 dB SPL for 8 h/day, 3 days consecutively. Auditory thresholds were assessed by auditory brainstem response, prior to and 7 days following noise exposure. On the seventh days after noise exposure, the cochlear sensory epithelia surface was observed microscopically and the cochleae were taken to study the ultrastructural changes. The results indicated that auditory threshold shift after noise exposure was higher in the ears treated with Ad.EGFP than that treated with Ad.c-myc-EGFP. Stereocilia loss and the disarrangement of outer hair cells were observed, with greater changes found in the Ad.EGFP group. Also, the ultrastructure changes were severe in the Ad.EGFP group, but not obvious in the Ad.c-myc-EGFP group. Therefore, c-myc gene might play an unexpected role in hearing functional and morphological protection from acoustic trauma.

  9. Leakage radiation interference microscopy.

    Science.gov (United States)

    Descrovi, Emiliano; Barakat, Elsie; Angelini, Angelo; Munzert, Peter; De Leo, Natascia; Boarino, Luca; Giorgis, Fabrizio; Herzig, Hans Peter

    2013-09-01

    We present a proof of principle for a new imaging technique combining leakage radiation microscopy with high-resolution interference microscopy. By using oil immersion optics it is demonstrated that amplitude and phase can be retrieved from optical fields, which are evanescent in air. This technique is illustratively applied for mapping a surface mode propagating onto a planar dielectric multilayer on a thin glass substrate. The surface mode propagation constant estimated after Fourier transformation of the measured complex field is well matched with an independent measurement based on back focal plane imaging.

  10. Leakage resilient password systems

    CERN Document Server

    Li, Yingjiu; Deng, Robert H

    2015-01-01

    This book investigates tradeoff between security and usability in designing leakage resilient password systems (LRP) and introduces two practical LRP systems named Cover Pad and ShadowKey. It demonstrates that existing LRP systems are subject to both brute force attacks and statistical attacks and that these attacks cannot be effectively mitigated without sacrificing the usability of LRP systems. Quantitative analysis proves that a secure LRP system in practical settings imposes a considerable amount of cognitive workload unless certain secure channels are involved. The book introduces a secur

  11. The Effect of PCDH15 Gene Variations on the Risk of Noise-induced Hearing Loss in a Chinese Population.

    Science.gov (United States)

    Xu, Xiang Rong; Wang, Jing Jing; Yang, Qiu Yue; Jiao, Jie; He, Li Hua; Yu, Shan Fa; Gu, Gui Zhen; Chen, Guo Shun; Zhou, Wen Hui; Wu, Hui; Li, Yan Hong; Zhang, Huan Ling; Zhang, Zeng Rui; Jin, Xian Ning

    2017-02-01

    Noise-induced hearing loss (NIHL) is a complex disease caused by interactions between environmental and genetic factors. This study investigated whether genetic variability in protocadherin related 15 (PCDH15) underlies an increased susceptibility to the development of NIHL in a Chinese population. The results showed that compared with the TT genotype of rs11004085, CT/CC genotypes were associated with an increased risk of NIHL [adjusted odds ratio (OR) = 2.64; 95% confidence interval (CI): 1.14-6.11, P = 0.024]. Additionally, significant interactions between the rs11004085 and rs978842 genetic variations and noise exposure were observed in the high-level exposure groups (P variations in PCDH15 modify the susceptibility to NIHL development in humans. Copyright © 2017 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  12. Hearing Screening

    Science.gov (United States)

    Johnson-Curiskis, Nanette

    2012-01-01

    Hearing levels are threatened by modern life--headsets for music, rock concerts, traffic noises, etc. It is crucial we know our hearing levels so that we can draw attention to potential problems. This exercise requires that students receive a hearing screening for their benefit as well as for making the connection of hearing to listening.

  13. Molecular mechanisms underlying the protective effects of hydrogen-saturated saline on noise-induced hearing loss.

    Science.gov (United States)

    Chen, Liwei; Han, Mingkun; Lu, Yan; Chen, Daishi; Sun, Xuejun; Yang, Shiming; Sun, Wei; Yu, Ning; Zhai, Suoqiang

    2017-10-01

    This study aimed to explore the molecular mechanism of the protective effects of hydrogen-saturated saline on NIHL. Guinea pigs were divided into three groups: hydrogen-saturated saline; normal saline; and control. For saline administration, the guinea pigs were given daily abdominal injections 3 d before and 1 h before noise exposure. ABR were tested to examine cochlear physiology changes. The changes of 8-hydroxy-desoxyguanosine (8-HOdG), interleukin-1 (IL-1), interleukin-6 (IL-6), interleukin-10 (IL-10), tumor necrosis factor-α (TNF-α), intercellular cell adhesion molecule-1 (ICAM-1) and high mobility group box-1 protein (HMGB1) in the cochlea were also examined. The results showed that pre-treatment with hydrogen-saturated saline could significantly attenuate noise-induced hearing loss. The concentration of 8-HOdG was also significantly decreased in the hydrogen-saturated saline group compared with the normal saline group. After noise exposure, the concentrations of IL-1, IL-6, TNF-α, and ICAM-1 in the cochlea of guinea pigs in the hydrogen-saturated saline group were dramatically reduced compared to those in the normal saline group. The concentrations of HMGB-1 and IL-10 in the hydrogen-saturated saline group were significantly higher than in those in the normal saline group immediately and at 7 d after noise exposure. This study revealed for the first time the protective effects of hydrogen-saturated saline on noise-induced hearing loss (NIHL) are related to both the anti-oxidative activity and anti-inflammatory activity.

  14. Perda auditiva induzida pelo ruído em trabalhadores de metalúrgica Noise induced hearing loss in metallurgical workers

    Directory of Open Access Journals (Sweden)

    Simone Adad Araújo

    Full Text Available Introdução: A perda auditiva induzida pelo ruído é uma patologia insidiosa cumulativa, que cresce ao longo dos anos de exposição ao ruído associado ao ambiente de trabalho. Objetivos: Identificar e quantificar a ocorrência de alterações auditivas sugestivas de Perda Auditiva Induzida pelo Ruído e os principais sintomas otorrinolaringológicos referidos pelos trabalhadores. Forma de estudo: prospectivo clínico randomizado. Casuística e métodos: Pesquisa realizada no período de janeiro a março de 2000 com 187 trabalhadores de indústria metalúrgica no município de Goiânia, avaliados por médicos otorrinolaringologistas através de roteiro de entrevista e audiometria ocupacional. Resultados: Foram obtidas audiometrias ocupacionais sendo: 21% sugestivas de PAIR, 72%, normais e 7%, sugestivas de outras doenças auditivas. Os sintomas auditivos mais freqüentes foram: dificuldade de compreensão da fala, 12%; hipoacusia, 7%; tinitus, 13%; sensação de plenitude auricular, 4%; otorreia, 6%; tonturas, 12%. Conclusão: Concluímos que em metalúrgica há ocorrência de alterações auditivas sugestivas de Perda Auditiva Induzida pelo Ruído e queixa de sintomas otorrinolaringológicos significativos.Introduction: Noise induced hearing loss is a cumulative pathological disease that increases over the years with exposure to noise associated with the work atmosphere. Objectives: To identify and quantify the occurrence of hearing loss suggestive of Noise Induced Hearing Loss (NIHL and the principle otolaryngological symptoms referred to by workers. Study design: prospective clinical randomized. Material and method: Research was carried out from January to March of 2000 with 187 metallurgical workers in the city of Goiânia, who were evaluated by otolaryngologists by means of a combination of interviews and occupational hearing exams. Results: Occupational hearing tests results were: 21% suggestive of NIHL, 72% normal, and 7% suggestive of

  15. Influence of risky and protective behaviors connected with listening to music on hearing loss and the noise induced threshold shift among students of the Medical University of Bialystok

    Directory of Open Access Journals (Sweden)

    Beata Modzelewska

    2017-03-01

    Full Text Available Background . Currently, significant changes have occurred in the character of sound exposure, along with the properties of the group affected by it. Thus, primary care physicians have to keep in mind that a sizable group of young adults comprises groups in which the prevalence of hearing loss is increasing. Objectives . The goal of the following study was to determine the auditory ability of the students attending the Medical University in Bialystok and to analyze their risky and protective behaviors relating to music consumption. Material and methods . In total, 230 students (age: 18–26 years completed a questionnaire about general personal information and their music-listening habits. Thereafter, pure tone audiometry at standard frequencies (0.25 kHz–8 kHz was performed. Results . Hearing loss was more frequent in subjects who listened to music at higher volumes (‘very loud’ – 22.2%, ‘loud’ – 3.9%, ‘not very loud’ – 2.1%, ‘quiet’ – 9.1%, p = 0.046. Hearing loss was more prevalent among those students who were living in a city with more than 50,000 inhabitants before starting higher education compared to the remaining subjects (7.95% vs. 0.97%, p = 0.025. Conclusions . The study demonstrated that surprisingly few medical students suffer from hearing loss or a noise induced threshold shift. There is no correlation between risky behavior such as a lengthy daily duration of listening to music or the type of headphone used and hearing loss. Hearing screening tests connected with education are indicated in the group of young adults due to the accumulative character of hearing damage.

  16. Occupational noise exposure and noise-induced hearing loss are associated with work-related injuries leading to admission to hospital.

    Science.gov (United States)

    Girard, Serge-André; Leroux, Tony; Courteau, Marilene; Picard, Michel; Turcotte, Fernand; Richer, Olivier

    2015-04-01

    This study focuses on work-related injuries that required admission to hospital in a population of male workers exposed to occupational noise (≥80 dBA) which some displayed a hearing loss due to their exposure. The study population count 46 550 male workers, 1670 (3.6%) of whom incurred at least one work-related injury requiring admission to hospital within a period of 5 years following hearing tests conducted between 1987 and 2005. The noise exposure and hearing loss-related data were gathered during occupational noise-induced hearing loss (NIHL) screening. The hospital data were used to identify all members of the study population who were admitted, and the reason for admission. Finally, access to the death-related data made it possible to identify participants who died during the course of the study. Cox proportional hazards model taking into account hearing status, noise levels, age and cumulative duration of noise exposure at the time of the hearing test established the risk of work-related injuries leading to admission to hospital. For each dB of hearing loss, a statistically significant risk increase was observed (HR=1.01 dB 95% CI 1.006 to 1.01). An association (HR=2.36 95% CI 2.01 to 2.77) was also found between working in an occupational ambient noise ≥100 dBA and the risk of injury. From a safety perspective, this issue is highly relevant; especially when workers are exposed to intense ambient noise and NIHL. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  17. COAST (Cisplatin ototoxicity attenuated by aspirin trial): A phase II double-blind, randomised controlled trial to establish if aspirin reduces cisplatin induced hearing-loss.

    Science.gov (United States)

    Crabb, Simon J; Martin, Karen; Abab, Julia; Ratcliffe, Ian; Thornton, Roger; Lineton, Ben; Ellis, Mary; Moody, Ronald; Stanton, Louise; Galanopoulou, Angeliki; Maishman, Tom; Geldart, Thomas; Bayne, Mike; Davies, Joe; Lamb, Carolynn; Popat, Sanjay; Joffe, Johnathan K; Nutting, Chris; Chester, John; Hartley, Andrew; Thomas, Gareth; Ottensmeier, Christian; Huddart, Robert; King, Emma

    2017-12-01

    Cisplatin is one of the most ototoxic chemotherapy drugs, resulting in a permanent and irreversible hearing loss in up to 50% of patients. Cisplatin and gentamicin are thought to damage hearing through a common mechanism, involving reactive oxygen species in the inner ear. Aspirin has been shown to minimise gentamicin-induced ototoxicity. We, therefore, tested the hypothesis that aspirin could also reduce ototoxicity from cisplatin-based chemotherapy. A total of 94 patients receiving cisplatin-based chemotherapy for multiple cancer types were recruited into a phase II, double-blind, placebo-controlled trial and randomised in a ratio of 1:1 to receive aspirin 975 mg tid and omeprazole 20 mg od, or matched placebos from the day before, to 2 days after, their cisplatin dose(s), for each treatment cycle. Patients underwent pure tone audiometry before and at 7 and 90 days after their final cisplatin dose. The primary end-point was combined hearing loss (cHL), the summed hearing loss at 6 kHz and 8 kHz, in both ears. Although aspirin was well tolerated, it did not protect hearing in patients receiving cisplatin (p-value = 0.233, 20% one-sided level of significance). In the aspirin arm, patients demonstrated mean cHL of 49 dB (standard deviation [SD] 61.41) following cisplatin compared with placebo patients who demonstrated mean cHL of 36 dB (SD 50.85). Women had greater average hearing loss than men, and patients treated for head and neck malignancy experienced the greatest cHL. Aspirin did not protect from cisplatin-related ototoxicity. Cisplatin and gentamicin may therefore have distinct ototoxic mechanisms, or cisplatin-induced ototoxicity may be refractory to the aspirin regimen used here. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. Approximate bilateral symmetry in evaporation-induced polycrystalline structures from droplets of wheat grain leakages and fluctuating asymmetry as quality indicator

    Science.gov (United States)

    Kokornaczyk, Maria Olga; Dinelli, Giovanni; Betti, Lucietta

    2013-01-01

    The present paper reports on an observation that dendrite-like polycrystalline structures from evaporating droplets of wheat grain leakages exhibit bilateral symmetry. The exactness of this symmetry, measured by means of fluctuating asymmetry, varies depending on the cultivar and stress factor influence, and seems to correspond to the seed germination rate. In the bodies of plants, animals, and humans, the exactness of bilateral symmetry is known to reflect the environmental conditions of an organism's growth, its health, and its success in sexual selection. In polycrystalline structures, formed under the same conditions, the symmetry exactness depends on the properties of the crystallizing solution such as the composition and viscosity; however, it has never been associated with sample quality. We hypothesize here that, as in living nature, the exactness of approximate bilateral symmetry might be considered a quality indicator also in crystallographic methods applied to food quality analysis.

  19. Protect Your Hearing at Work

    Centers for Disease Control (CDC) Podcasts

    Noise-induced hearing loss is one of the most common work-related illnesses. This podcast features information from CDC’s National Institute for Occupational Safety and Health on how to protect yourself from work-related noise-induced hearing loss.

  20. Noise-Induced Hearing Loss in Relation With Vibration Disease and Exposure to Vibration Among Employees in Latvia

    Directory of Open Access Journals (Sweden)

    Kristina Karganova

    2016-05-01

    Full Text Available Occupational noise-induced hearing loss (ONIHL is a form of sensorineural hearing loss that is caused by intensive and continuous exposure to noise. It is one of the most frequently encountered occupational diseases worldwide despite numerous available control measures. ONIHL is a preventable disease, however, once the damage to the inner ear structures has occurred no medical intervention can reverse it. Aim. The purpose of this study was to describe and analyse incidence of registered cases of ONIHL in relation to vibration disease and exposure to vibration among employees in Latvia between 2005 and 2014. Materials and methods. The data used in the study were acquired from the Latvian State Register of Patients with Occupational Diseases and afterwards analyzed with applicable statistical tests using both Excel and IBM SPSS programmes to compare epidemiological parameters between ONIHL, vibration disease (VD and exposure to vibration and to identify the association between them. Results. In total data were obtained about 2302 patients with 2562 cases of occupational ear, nose and throat (ENT diseases. Out of them ONIHL was registered in 1699 cases (819 cases were ONIHL in combination with VD. Most of the employees with ONIHL and ONIHL simultaneously with VD were males aged 55-64. There was found statistically significant association between ONIHL and VD (p<0.001; Cramer’s V=0.42; OR=32.08; 95% confidence interval (95% CI 19.62–52.45. Statistically significant association was encountered between ONIHL and exposure to vibration as well (p<0.001; Cramer’s V=0.46; OR=10.97; 95% CI: 8.63–13.96. Conclusion. In total ONIHL was the most prevalent occupational ENT disease followed by chronic laryngitis, chronic pharyngitis and allergic rhinitis. Statistically significant association was found between ONIHL and VD, and ONIHL and exposure to vibration. Study revealed that hearing quality of workers employed in manufacturing; transport, storage

  1. Modeling the Unites States government's economic cost of noise-induced hearing loss for a military population.

    Science.gov (United States)

    Tufts, Jennifer B; Weathersby, Paul K; Rodriguez, Francisco A

    2010-05-01

    The purpose of this paper is to demonstrate the feasibility and utility of developing economic cost models for noise-induced hearing loss (NIHL). First, we outline an economic model of NIHL for a population of US Navy sailors with an "industrial"-type noise exposure. Next, we describe the effect on NIHL-related cost of varying the two central model inputs--the noise-exposure level and the duration of exposure. Such an analysis can help prioritize promising areas, to which limited resources to reduce NIHL-related costs should be devoted. NIHL-related costs borne by the US government were computed on a yearly basis using a finite element approach that took into account varying levels of susceptibility to NIHL. Predicted hearing thresholds for the population were computed with ANSI S3.44-1996 and then used as the basis for the calculation of NIHL-related costs. Annual and cumulative costs were tracked. Noise-exposure level and duration were systematically varied to determine their effects on the expected lifetime NIHL-related cost of a specific US Navy sailor population. Our nominal noise-exposure case [93 dB(A) for six years] yielded a total expected lifetime cost of US $13,472 per sailor, with plausible lower and upper bounds of US $2,500 and US $26,000. Starting with the nominal case, a decrease of 50% in exposure level or duration would yield cost savings of approximately 23% and 19%, respectively. We concluded that a reduction in noise level would be more somewhat more cost-effective than the same percentage reduction in years of exposure. Our economic cost model can be used to estimate the changes in NIHL-related costs that would result from changes in noise-exposure level and/or duration for a single military population. Although the model is limited at present, suggestions are provided for adapting it to civilian populations.

  2. Early indication of noise-induced hearing loss from PMP use in adolescents: A cross-sectional analysis

    Directory of Open Access Journals (Sweden)

    Diana C Colon

    2016-01-01

    Full Text Available Context: Distortion product otoacoustic emissions (DPOAEs may indicate preclinical noise-induced hearing loss (NIHL in adolescents from unsafe personal music player (PMP use. Aims: The objective, therefore, was to observe preclinical signs of NIHL in 9th grade adolescents with clinically normal hearing by comparing DPOAE signals between different levels of A-weighted equivalent PMP exposure. Settings and Design: Subjects were recruited from all secondary-level schools located in the city of Regensburg, Germany during two academic years 2009/2010 and 2010/2011. Subjects and Methods: A-weighted equivalent sound pressure levels (SPLs for a 40-hour work week (LAeq,40h were estimated from questionnaire responses on output and duration of PMP use of the previous week. Subjects were then categorized into four levels of exposure: 85 to <90, and ≥90 A-weighted Decibel [dB(A]. DPOAE signals were collected by trained audiological staff, applying a standard optimized protocol, at the Department of Otorhinolaryngology of the University Hospital Regensburg. Statistical Analysis Used: Mean DPOAE signals were compared between levels by unpaired t test. Novel linear regression models adjusting for other leisure noise exposures and with outcome variables DPoutcome and 4 kilo Hertz (kHz DPOAEs estimated effects between levels. Results: A total of 1468 subjects (56% female, mostly aged 15 or 16 years were available for analysis. Comparison of DPOAE means by PMP exposure typically showed no greater than 1 dB difference between groups. In fact, comparisons between ≥90 dB(A and <80 dB(A presented the least differences in magnitude. Both DPoutcome and 4 kHz linear regression models presented a weak association with the 4-level PMP exposure variable. An expected dose-response to PMP exposure was not observed in any analyses. Conclusions: DPOAE signal strength alone cannot indicate preclinical NIHL in adolescents.

  3. Activity of coenzyme Q 10 (Q-Ter multicomposite) on recovery time in noise-induced hearing loss.

    Science.gov (United States)

    Staffa, Paola; Cambi, Jacopo; Mezzedimi, Chiara; Passali, Desiderio; Bellussi, Luisa

    2014-01-01

    A potential consequence of exposure to noise is a temporary reduction in auditory sensitivity known as temporary threshold shift (TTS), which mainly depends on the intensity and duration of exposure to the noise. Recovery time is related to the amount of initial hearing loss, and the most recovery takes place during the first 15 min following exposure. This study evaluated the efficacy in otoprotection against noise-induced hearing loss of an orally administrated food supplement containing coenzyme Q 10 -Ter. This water-soluble formulation of coenzyme Q 10 shows better bioavailability than the native form and has been found to have a protective effect on outer hair cells after exposure to noise in animal models. Thirty volunteers were enrolled, and the right ear of each subject was exposed to a narrow-band noise centered at 3 kHz for 10 min at the intensity of 90 dB HL. In the 30 subjects enrolled, TTS was evaluated after 2, 15, and 30 min and the recovery time was recorded in each subject. The longest recovery time was 45 min. Among the 18 subjects who underwent a second test after treatment with Q-Ter, the mean recovery time was 31.43 min. The results of the present study show that 30 days' treatment with Q-Ter can aid faster recovery after exposure to noise (P < 0.0001). The reduction in the recovery time following treatment can be explained by Q-Ter-mediated improvement of the outer hair cells' response to oxidative stress.

  4. Investigation of internal feedback in hearing aids

    DEFF Research Database (Denmark)

    Friis, Lars

    2009-01-01

    with vibroacoustic transmission from the receiver to the microphones often occur during the use of hearing aids. This transmission causes feedback at certain critical gain levels where it produces a loud uncomfortable squealing. Consequently feedback often constitutes the limiting factor for the maximum obtainable...... gain in the hearing aid and it therefore represents a critical design problem. Feedback in hearing aids is usually divided into external and internal feedback. External feedback is caused by the leakage of sound from the ear canal whereas internal feedback is due to transmission of sound and vibrations...... internally in the hearing aid. As a result of reducing the size of hearing aids, manufacturers have experienced an increase in internal feedback problems. The main objective of the present thesis is therefore to examine the vibroacoustic mechanisms responsible for internal feedback in hearing aids...

  5. Clinical evaluation and mitochondrial DNA sequence analysis in two Chinese families with aminoglycoside-induced and non-syndromic hearing loss

    International Nuclear Information System (INIS)

    Zhao Lidong; Wang Qiuju; Qian Yaping; Li Ronghua; Cao Juayng; Hart, Laura Christine; Zhai Suoqiang; Han Dongyi; Young Wieyen; Guan Minxin

    2005-01-01

    We report here the clinical, genetic, and molecular characterization of two Chinese pedigrees with aminoglycoside-induced and non-syndromic hearing impairment. Clinical evaluation revealed the variable phenotype of hearing impairment including audiometric configuration in these subjects. Penetrances of hearing loss in BJ105 and BJ106 pedigrees are 67% and 33%, respectively. In particular, three of 10 affected matrilineal relatives of BJ105 pedigree had aminoglycoside-induced hearing loss, while seven affected matrilineal relatives in BJ105 pedigree and six affected matrilineal relatives in BJ106 pedigree did not have a history of exposure to aminoglycosides. Sequence analysis of the complete mitochondrial genomes in these pedigrees showed the identical homoplasmic A1555G mutation and distinct sets of mtDNA variants belonging to haplogroups F3 and M7b. These variants showed no evolutionary conservation, implying that mitochondrial haplotype may not play a significant role in the phenotypic expression of the A1555G mutation in these Chinese pedigrees. However, aminoglycosides and nuclear backgrounds appear to be major modifier factors for the phenotypic manifestation of the A1555G mutation in these Chinese families

  6. Clinical and molecular analysis of a four-generation Chinese family with aminoglycoside-induced and nonsyndromic hearing loss associated with the mitochondrial 12S rRNA C1494T mutation

    International Nuclear Information System (INIS)

    Wang Qiuju; Li Qingzhong; Han Dongyi; Zhao Yali; Zhao Lidong; Qian Yaping; Yuan Hu; Li Ronghua; Zhai Suoqiang; Young Wieyen; Guan Minxin

    2006-01-01

    We report here the clinical, genetic, and molecular characterization of a four-generation Chinese family with aminoglycoside-induced and nonsyndromic hearing loss. Five of nine matrilineal relatives had aminoglycoside-induced hearing loss. These matrilineal relatives exhibited variable severity and audiometric configuration of hearing impairment, despite sharing some common features: being bilateral and having sensorineural hearing impairment. Sequence analysis of mitochondrial DNA (mtDNA) in the pedigree identified 16 variants and the homoplasmic 12S rRNA C1494T mutation, which was associated with hearing loss in the other large Chinese family. In fact, the occurrence of the C1494T mutation in these genetically unrelated pedigrees affected by hearing impairment strongly indicated that this mutation is involved in the pathogenesis of aminoglycoside-induced and nonsyndromic hearing loss. However, incomplete penetrance of hearing loss indicated that the C1494T mutation itself is not sufficient to produce a clinical phenotype but requires the involvement of modifier factors for the phenotypic expression. Those mtDNA variants, showing no evolutional conservation, may not have a potential modifying role in the pathogenesis of the C1494T mutation. However, nuclear background seems to contribute to the phenotypic variability of matrilineal relatives in this family. Furthermore, aminoglycosides modulate the expressivity and penetrance of deafness associated with the C1494T mutation in this family

  7. Acoustically Induced Streaming Flows near a Model Cod Otolith and their Potential Implications for Fish Hearing

    Energy Technology Data Exchange (ETDEWEB)

    Kotas, Charlotte W [ORNL; Rogers, Peter [Georgia Institute of Technology; Yoda, Minami [Georgia Institute of Technology

    2011-01-01

    The ears of fishes are remarkable sensors for the small acoustic disturbances associated with underwater sound. For example, each ear of the Atlantic cod (Gadus morhua) has three dense bony bodies (otoliths) surrounded by fluid and tissue, and detects sounds at frequencies from 30 to 500 Hz. Atlantic cod have also been shown to localize sounds. However, how their ears perform these functions is not fully understood. Steady streaming, or time-independent, flows near a 350% scale model Atlantic cod otolith immersed in a viscous fluid were studied to determine if these fluid flows contain acoustically relevant information that could be detected by the ear s sensory hair cells. The otolith was oscillated sinusoidally at various orientations at frequencies of 8 24 Hz, corresponding to an actual frequency range of 280 830 Hz. Phaselocked particle pathline visualizations of the resulting flows give velocity, vorticity, and rate of strain fields over a single plane of this mainly two-dimensional flow. Although the streaming flows contain acoustically relevant information, the displacements due to these flows are likely too small to explain Atlantic cod hearing abilities near threshold. The results, however, may suggest a possible mechanism for detection of ultrasound in some fish species.

  8. Hearing Aids

    Science.gov (United States)

    ... primarily useful in improving the hearing and speech comprehension of people who have hearing loss that results ... and you can change the program for different listening environments—from a small, quiet room to a ...

  9. Lung protein leakage in feline septic shock.

    Science.gov (United States)

    Schützer, K M; Larsson, A; Risberg, B; Falk, A

    1993-06-01

    The aim of the present study was to explore lung microvascular leakage of protein and water in a feline model of septic shock, using a double isotope technique with external gamma camera detection and gravimetric lung water measurements. The experiments were performed on artificially ventilated cats. One group of cats (n = 8) was given an infusion of live Escherichia coli bacteria, and another group (n = 5) served as a control group receiving saline. Plasma transferrin was radiolabeled in vivo with indium-113m-chloride, and erythrocytes were labeled with technetium-99m. The distribution of these isotopes in the lungs was continuously measured with a gamma camera. A normalized slope index (NSI) was calculated, indicative of the transferrin accumulation corrected for changes in local blood volume that reflect protein leakage. In the septic group there was a protein leakage after bacterial infusion, with a NSI of 39 x 10(-4) +/- 5 x 10(-4) min-1 (mean +/- SEM), and the PaO2 diminished from 21 +/- 1 to 9.5 +/- 1 kPa. In control cats a slight protein leakage with a NSI of 9 +/- 10(-4) +/- 2 x 10(-4) min-1 was detected, probably caused by the operative procedure, but PaO2 did not change. Wet-to-dry-weight ratios of postmortem lungs were not significantly different between the groups. It was concluded that an intravenous infusion of live E. coli bacteria induces a lung capillary protein leakage without increased lung water and a concomitantly disturbed gas exchange.(ABSTRACT TRUNCATED AT 250 WORDS)

  10. Hear, hear, what, what

    Energy Technology Data Exchange (ETDEWEB)

    1985-02-01

    Noise is now the most serious health hazard in industry. People risk suffering severe damage to their hearing and health generally through exposure to noise levels which exceed the risk limit of 95-90 dB(A). Stress related problems are often directly the result of exposure to noise. Furthermore, noise leads to reduced productivity, increased absenteeism and compensation claims. In a series of eight reports, Bilson technologists detail the specific noise problems commonly encountered in each of the major areas of industry. These range from the concrete and construction industry through sawmilling, wood working, mining and mechanical engineering, to textile and food manufacture. This report discusses the noise in mining, considering drills, load haul dump machines, surface mines, earth moving equipment, treatment plants, frequency spectra of noise, and finally, choice of hearing protection.

  11. Hearing Problems

    Science.gov (United States)

    ... Read MoreDepression in Children and TeensRead MoreBMI Calculator Hearing ProblemsLoss in the ability to hear or discriminate ... This flow chart will help direct you if hearing loss is a problem for you or a ...

  12. Leakage monitoring device and method

    International Nuclear Information System (INIS)

    Yamada, Izumi; Matsui, Yuji; Fujimori, Haruo.

    1995-01-01

    In a water leakage monitor for a steam generator, output signals from an acoustic sensor disposed in the vicinity of a region to be monitored is subjected to phasing calculation (beam forming calculation) to determine the distribution of a sound source intensity distribution. A peak is retrieved based on the distribution of the sound source intensity distribution. A correction coefficient depending on the position of the peak is multiplied to the sound source intensity. The presence or absence of leakage is determined based on the degree of the sound source intensity after the completion of correction. Namely, a relative value of sound source intensity for each of the portions in the region to be monitored is determined, and the point of the greatest sound source intensity is assumed as a leaking point, to determine the position of the leakage. An absolute value of the sound source intensity at the leaking point is determined by such a constitution that a correction coefficient depending on the position is multiplied to the intensity of the position of the peak in the distribution of the sound intensity. A threshold value for the determination of the presence or absence of the leakage can be set if a relation between an amount of the leakage previously determined experimentally and the intensity of the sound source. Then, a countermeasure can easily be taken after the detection of the leakage and a restoring operation can be carried out rapidly after the occurrence of leakage while avoiding unnecessary shutdown. (N.H.)

  13. Amplification of transcutaneous and percutaneous bone-conduction devices with a test-band in an induced model of conductive hearing loss.

    Science.gov (United States)

    Park, Marn Joon; Lee, Jae Ryung; Yang, Chan Joo; Yoo, Myung Hoon; Jin, In Suk; Choi, Chi Ho; Park, Hong Ju

    2016-11-01

    Transcutaneous devices have a disadvantage, the dampening effect by soft tissue between the bone and devices. We investigated hearing outcomes with percutaneous and transcutaneous devices using test-bands in an induced unilateral conductive hearing loss. Comparison of hearing outcomes of two devices in the same individuals. The right ear was plugged in 30 subjects and a test-band with devices (Cochlear™ Baha® BP110 Power and Sophono® Alpha-2 MPO™) was applied on the right mastoid tip with the left ear masked. Sound-field thresholds, speech recognition thresholds (SRTs), and word recognition scores (WRSs) were compared. Aided thresholds of Sophono were significantly better than those of Baha at most frequencies. Sophono WRSs (86 ± 12%) at 40 dB SPL and SRTs (14 ± 5 dB HL) were significantly better than those (73 ± 24% and 23 ± 8 dB HL) of Baha. However, Sophono WRSs (98 ± 3%) at 60 dB SPL did not differ from Baha WRSs (95 ± 12%). Amplifications of the current transcutaneous device were not inferior to those of percutaneous devices with a test-band in subjects with normal bone-conduction thresholds. Since the percutaneous devices can increase the gain when fixed to the skull by eliminating the dampening effect, both devices are expected to provide sufficient hearing amplification.

  14. The music listening preferences and habits of youths in Singapore and its relation to leisure noise-induced hearing loss.

    Science.gov (United States)

    Lee, Gary Jek Chong; Lim, Ming Yann; Kuan, Angeline Yi Wei; Teo, Joshua Han Wei; Tan, Hui Guang; Low, Wong Kein

    2014-02-01

    Noise-induced hearing loss (NIHL) is a preventable condition, and much has been done to protect workers from it. However, thus far, little attention has been given to leisure NIHL. The purpose of this study is to determine the possible music listening preferences and habits among young people in Singapore that may put them at risk of developing leisure NIHL. In our study, the proportion of participants exposed to > 85 dBA for eight hours a day (time-weighted average) was calculated by taking into account the daily number of hours spent listening to music and by determining the average sound pressure level at which music was listened to. A total of 1,928 students were recruited from Temasek Polytechnic, Singapore. Of which, 16.4% of participants listened to portable music players with a time-weighted average of > 85 dBA for 8 hours. On average, we found that male students were more likely to listen to music at louder volumes than female students (p students in our study listened to louder music than the Chinese students (p leisure NIHL from music delivered via earphones. As additional risks due to exposure to leisure noise from other sources was not taken into account, the extent of the problem of leisure NIHL may be even greater. There is a compelling need for an effective leisure noise prevention program among young people in Singapore.

  15. Inner volume leakage during integrated leakage rate testing

    International Nuclear Information System (INIS)

    Glover, J.P.

    1987-01-01

    During an integrated leak rate test (ILRT), the containment structure is maintained at test pressure with most penetrations isolated. Since penetrations typically employ dual isolation, the possibility exists for the inner isolation to leak while the outer holds. In this case, the ILRT instrumentation system would indicate containment out-leakage when, in fact, only the inner volume between closures is being pressurized. The problem is compounded because this false leakage is not readily observable outside of containment by standard leak inspection techniques. The inner volume leakage eventually subsides after the affected volumes reach test pressure. Depending on the magnitude of leakage and the size of the volumes, equalization could occur prior to the end of the pretest stabilization period, or significant false leakages may persist throughout the entire test. Two simple analyses were performed to quantify the effects of inside volume leakages. First, a lower bound for the equalization time was found. A second analysis was performed to find an approximate upper bound for the stabilization time. The results of both analyses are shown

  16. Adaptive Processes in Hearing

    DEFF Research Database (Denmark)

    Santurette, Sébastien; Christensen-Dalsgaard, Jakob; Tranebjærg, Lisbeth

    2018-01-01

    , and is essential to achieve successful speech communication, correct orientation in our full environment, and eventually survival. These adaptive processes may differ in individuals with hearing loss, whose auditory system may cope via ‘‘readapting’’ itself over a longer time scale to the changes in sensory input...... induced by hearing impairment and the compensation provided by hearing devices. These devices themselves are now able to adapt to the listener’s individual environment, attentional state, and behavior. These topics related to auditory adaptation, in the broad sense of the term, were central to the 6th...... International Symposium on Auditory and Audiological Research held in Nyborg, Denmark, in August 2017. The symposium addressed adaptive processes in hearing from different angles, together with a wide variety of other auditory and audiological topics. The papers in this special issue result from some...

  17. Leakage characterization of top select transistor for program disturbance optimization in 3D NAND flash

    Science.gov (United States)

    Zhang, Yu; Jin, Lei; Jiang, Dandan; Zou, Xingqi; Zhao, Zhiguo; Gao, Jing; Zeng, Ming; Zhou, Wenbin; Tang, Zhaoyun; Huo, Zongliang

    2018-03-01

    In order to optimize program disturbance characteristics effectively, a characterization approach that measures top select transistor (TSG) leakage from bit-line is proposed to quantify TSG leakage under program inhibit condition in 3D NAND flash memory. Based on this approach, the effect of Vth modulation of two-cell TSG on leakage is evaluated. By checking the dependence of leakage and corresponding program disturbance on upper and lower TSG Vth, this approach is validated. The optimal Vth pattern with high upper TSG Vth and low lower TSG Vth has been suggested for low leakage current and high boosted channel potential. It is found that upper TSG plays dominant role in preventing drain induced barrier lowering (DIBL) leakage from boosted channel to bit-line, while lower TSG assists to further suppress TSG leakage by providing smooth potential drop from dummy WL to edge of TSG, consequently suppressing trap assisted band-to-band tunneling current (BTBT) between dummy WL and TSG.

  18. Genome-wide association study identifies nox3 as a critical gene for susceptibility to noise-induced hearing loss.

    Directory of Open Access Journals (Sweden)

    Joel Lavinsky

    2015-04-01

    Full Text Available In the United States, roughly 10% of the population is exposed daily to hazardous levels of noise in the workplace. Twin studies estimate heritability for noise-induced hearing loss (NIHL of approximately 36%, and strain specific variation in sensitivity has been demonstrated in mice. Based upon the difficulties inherent to the study of NIHL in humans, we have turned to the study of this complex trait in mice. We exposed 5 week-old mice from the Hybrid Mouse Diversity Panel (HMDP to a 10 kHz octave band noise at 108 dB for 2 hours and assessed the permanent threshold shift 2 weeks post exposure using frequency specific stimuli. These data were then used in a genome-wide association study (GWAS using the Efficient Mixed Model Analysis (EMMA to control for population structure. In this manuscript we describe our GWAS, with an emphasis on a significant peak for susceptibility to NIHL on chromosome 17 within a haplotype block containing NADPH oxidase-3 (Nox3. Our peak was detected after an 8 kHz tone burst stimulus. Nox3 mutants and heterozygotes were then tested to validate our GWAS. The mutants and heterozygotes demonstrated a greater susceptibility to NIHL specifically at 8 kHz both on measures of distortion product otoacoustic emissions (DPOAE and on auditory brainstem response (ABR. We demonstrate that this sensitivity resides within the synaptic ribbons of the cochlea in the mutant animals specifically at 8 kHz. Our work is the first GWAS for NIHL in mice and elucidates the power of our approach to identify tonotopic genetic susceptibility to NIHL.

  19. Analysis of serum microRNA expression in male workers with occupational noise-induced hearing loss

    Directory of Open Access Journals (Sweden)

    Y.H. Li

    2018-01-01

    Full Text Available Occupational noise-induced hearing loss (ONIHL is a prevalent occupational disorder that impairs auditory function in workers exposed to prolonged noise. However, serum microRNA expression in ONIHL subjects has not yet been studied. We aimed to compare the serum microRNA expression profiles in male workers of ONIHL subjects and controls. MicroRNA microarray analysis revealed that four serum microRNAs were differentially expressed between controls (n=3 and ONIHL subjects (n=3. Among these microRNAs, three were upregulated (hsa-miR-3162-5p, hsa-miR-4484, hsa-miR-1229-5p and one was downregulated (hsa-miR-4652-3p in the ONIHL group (fold change >1.5 and Pbon value <0.05. Real time quantitative PCR was conducted for validation of the microRNA expression. Significantly increased serum levels of miR-1229-5p were found in ONIHL subjects compared to controls (n=10 for each group; P<0.05. A total of 659 (27.0% genes were predicted as the target genes of miR-1229-5p. These genes were involved in various pathways, such as mitogen-activated protein kinase (MAPK signaling pathway. Overexpression of miR-1229-5p dramatically inhibited the luciferase activity of 3′ UTR segment of MAPK1 (P<0.01. Compared to the negative control, HEK293T cells expressing miR-1229-5p mimics showed a significant decline in mRNA levels of MAPK1 (P<0.05. This preliminary study indicated that serum miR-1229-5p was significantly elevated in ONIHL subjects. Increased miR-1229-5p may participate in the pathogenesis of ONIHL through repressing MAPK1 signaling.

  20. Analysis of serum microRNA expression in male workers with occupational noise-induced hearing loss.

    Science.gov (United States)

    Li, Y H; Yang, Y; Yan, Y T; Xu, L W; Ma, H Y; Shao, Y X; Cao, C J; Wu, X; Qi, M J; Wu, Y Y; Chen, R; Hong, Y; Tan, X H; Yang, L

    2018-01-11

    Occupational noise-induced hearing loss (ONIHL) is a prevalent occupational disorder that impairs auditory function in workers exposed to prolonged noise. However, serum microRNA expression in ONIHL subjects has not yet been studied. We aimed to compare the serum microRNA expression profiles in male workers of ONIHL subjects and controls. MicroRNA microarray analysis revealed that four serum microRNAs were differentially expressed between controls (n=3) and ONIHL subjects (n=3). Among these microRNAs, three were upregulated (hsa-miR-3162-5p, hsa-miR-4484, hsa-miR-1229-5p) and one was downregulated (hsa-miR-4652-3p) in the ONIHL group (fold change >1.5 and Pbon value <0.05). Real time quantitative PCR was conducted for validation of the microRNA expression. Significantly increased serum levels of miR-1229-5p were found in ONIHL subjects compared to controls (n=10 for each group; P<0.05). A total of 659 (27.0%) genes were predicted as the target genes of miR-1229-5p. These genes were involved in various pathways, such as mitogen-activated protein kinase (MAPK) signaling pathway. Overexpression of miR-1229-5p dramatically inhibited the luciferase activity of 3' UTR segment of MAPK1 (P<0.01). Compared to the negative control, HEK293T cells expressing miR-1229-5p mimics showed a significant decline in mRNA levels of MAPK1 (P<0.05). This preliminary study indicated that serum miR-1229-5p was significantly elevated in ONIHL subjects. Increased miR-1229-5p may participate in the pathogenesis of ONIHL through repressing MAPK1 signaling.

  1. Association of genetic variations in FOXO3 gene with susceptibility to noise induced hearing loss in a Chinese population.

    Directory of Open Access Journals (Sweden)

    Haoran Guo

    Full Text Available Noise induced hearing loss (NIHL, a multifactorial disease involving both genetic and environmental factors, is one of the most important occupational health hazards. Nonetheless, the influence of FOXO3 variants on NIHL risk have not been illuminated. This research was conducted to explore the effects of FOXO3 polymorphisms on individual susceptibility to NIHL. A total of 2689 industrial workers from one textile factory of east China were recruited to participate in the current research. Venous blood was collected, questionnaire and pure-tone audiometry (PTA was conducted by specialist physicians. Then, we performed genotyping of three selected SNPs (rs2802292, rs10457180, and rs12206094 in FOXO3 gene in 566 NIHL patients and 566 controls. Subsequently, the main effects of genotype and its interactions were evaluated. Our results revealed that individuals with the G allele of rs2802292, G allele of rs10457180, T allele of rs12206094 (OR = 1.43, 1.43, and 1.31 respectively and the haplotype GAC and others (TGT/GGT/GGC/GAT (rs2802292-rs10457180-rs12206094 (OR = 1.49 and 2.09 respectively are associated with an increased risk of NIHL in a Chinese population. Stratified analysis showed that an increased NIHL risk was found in the subjects who exposed to noise >16 years with rs2802292 GG/GT and rs10457180 AG/GG genotype with an OR of 1.62 and 1.66 respectively. Multifactor dimensionality reduction analysis indicated that rs10457180, rs2802292, and rs12206094 have interactions and are related to increased NIHL risk (OR = 1.53. The genetic polymorphism rs2802292, rs10457180, and rs12206094 within FOXO3 gene are associated with an increased risk of NIHL in a Chinese population and have potential to be biomarkers for noise exposed workers.

  2. Hearing visuo-tactile synchrony - Sound-induced proprioceptive drift in the invisible hand illusion.

    Science.gov (United States)

    Darnai, Gergely; Szolcsányi, Tibor; Hegedüs, Gábor; Kincses, Péter; Kállai, János; Kovács, Márton; Simon, Eszter; Nagy, Zsófia; Janszky, József

    2017-02-01

    The rubber hand illusion (RHI) and its variant the invisible hand illusion (IHI) are useful for investigating multisensory aspects of bodily self-consciousness. Here, we explored whether auditory conditioning during an RHI could enhance the trisensory visuo-tactile-proprioceptive interaction underlying the IHI. Our paradigm comprised of an IHI session that was followed by an RHI session and another IHI session. The IHI sessions had two parts presented in counterbalanced order. One part was conducted in silence, whereas the other part was conducted on the backdrop of metronome beats that occurred in synchrony with the brush movements used for the induction of the illusion. In a first experiment, the RHI session also involved metronome beats and was aimed at creating an associative memory between the brush stroking of a rubber hand and the sounds. An analysis of IHI sessions showed that the participants' perceived hand position drifted more towards the body-midline in the metronome relative to the silent condition without any sound-related session differences. Thus, the sounds, but not the auditory RHI conditioning, influenced the IHI. In a second experiment, the RHI session was conducted without metronome beats. This confirmed the conditioning-independent presence of sound-induced proprioceptive drift in the IHI. Together, these findings show that the influence of visuo-tactile integration on proprioceptive updating is modifiable by irrelevant auditory cues merely through the temporal correspondence between the visuo-tactile and auditory events. © 2016 The British Psychological Society.

  3. Remaining gaps for "safe" CO2 storage: the INGV CO2GAPS vision of "learning by doing" monitoring geogas leakage, reservoirs contamination/mixing and induced/triggered seismicity

    Science.gov (United States)

    Quattrocchi, F.; Vinciguerra, S.; Chiarabba, C.; Boschi, E.; Anselmi, M.; Burrato, P.; Buttinelli, M.; Cantucci, B.; Cinti, D.; Galli, G.; Improta, L.; Nazzari, M.; Pischiutta, M.; Pizzino, L.; Procesi, M.; Rovelli, A.; Sciarra, A.; Voltattorni, N.

    2012-12-01

    The CO2GAPS project proposed by INGV is intended to build up an European Proposal for a new kind of research strategy in the field of the geogas storage. Aim of the project would be to fill such key GAPS concerning the main risks associated to CO2 storage and their implications on the entire Carbon Capture and Storage (CCS) process, which are: i) the geogas leakage both in soils and shallow aquifers, up to indoor seepage; ii) the reservoirs contamination/mixing by hydrocarbons and heavy metals; iii) induced or triggered seismicity and microseismicity, especially for seismogenic blind faults. In order to consider such risks and make the CCS public acceptance easier, a new kind of research approach should be performed by: i) a better multi-disciplinary and "site specific" risk assessment; ii) the development of more reliable multi-disciplinary monitoring protocols. In this view robust pre-injection base-lines (seismicity and degassing) as well as identification and discrimination criteria for potential anomalies are mandatory. CO2 injection dynamic modelling presently not consider reservoirs geomechanical properties during reactive mass-transport large scale simulations. Complex simulations of the contemporaneous physic-chemical processes involving CO2-rich plumes which move, react and help to crack the reservoir rocks are not totally performed. These activities should not be accomplished only by the oil-gas/electric companies, since the experienced know-how should be shared among the CCS industrial operators and research institutions, with the governments support and overview, also flanked by a transparent and "peer reviewed" scientific popularization process. In this context, a preliminary and reliable 3D modelling of the entire "storage complex" as defined by the European Directive 31/2009 is strictly necessary, taking into account the above mentioned geological, geochemical and geophysical risks. New scientific results could also highlighting such opportunities

  4. Hearing Impairment

    Science.gov (United States)

    ... Ear Hears Think about how you can feel speakers vibrate on your sound system or feel your throat vibrate when you speak. Sound, which is made up of invisible waves of energy, causes these vibrations. Hearing begins when sound waves that travel through ...

  5. Protect Your Hearing at Work

    Centers for Disease Control (CDC) Podcasts

    2015-11-09

    Noise-induced hearing loss is one of the most common work-related illnesses. This podcast features information from CDC’s National Institute for Occupational Safety and Health on how to protect yourself from work-related noise-induced hearing loss.  Created: 11/9/2015 by National Institute for Occupational Safety and Health (NIOSH).   Date Released: 11/9/2015.

  6. Containment leakage rate testing requirements

    International Nuclear Information System (INIS)

    Arndt, E.G.

    1992-01-01

    This report presents the status of several documents under revision or development that provide requirements and guidance for testing nuclear power plant containment systems for leakage rates. These documents include the general revision to 10 CFR Part 50, Appendix J; the regulatory guide affiliated with the revision to Appendix J; the national standard that the regulatory guide endorses, ANSI/ANS-56.8, 'Containment System Leakage Rate Testing Requirements'; and the draft industry Licensing Topical Report, 'Standardized Program for Primary Containment Integrity Testing'. The actual or potential relationships between these documents are also explored

  7. Lungfish Hearing

    DEFF Research Database (Denmark)

    Christensen, Christian Bech; Madsen, Peter Teglberg; Christensen-Dalsgaard, Jakob

    Recent research has shown that tympanic middle ears evolved independently in the major vertebrate groups and represent independent experiments in terrestrial hearing. Furthermore, the tympanic ear emerged quite late – ap - proximately 120 mya after the origin of the tetrapods and approximately 70...... my after the first truly terrestrial tetrapods emerged. One of the major challenges is to understand the transitional stages from tetrapod ancestors to the tympanic tetrapod ear, for example how a non-tympanic ear functions in terrestrial hearing. Lungfish are the closest living relatives...... and urodeles. Based on ABR and vibration measurements also on amphib - ians, lizards, snakes and alligators we can outline scenarios for the initial adaptations of the middle ear to non-tympanic hearing and assess the selection pressures later adapting the middle ear for tympanic hearing. Hearing by bone...

  8. Noise-induced hearing loss in Korean workers: co-exposure to organic solvents and heavy metals in nationwide industries.

    Directory of Open Access Journals (Sweden)

    Yoon-Hyeong Choi

    Full Text Available BACKGROUND: Noise exposure is a well-known contributor to work-related hearing loss. Recent biological evidence suggests that exposure to ototoxic chemicals such as organic solvents and heavy metals may be additional contributors to hearing loss. However, in industrial settings, it is difficult to determine the risks of hearing loss due to these chemicals in workplaces accompanied by excessive noise exposure. A few studies suggest that the effect of noise may be enhanced by ototoxic chemicals. Therefore, this study investigated whether co-exposure to organic solvents and/or heavy metals in the workplace modifies the risk of noise exposure on hearing loss in a background of excessive noise. METHODS: We examined 30,072 workers nationwide in a wide range of industries from the Korea National Occupational Health Surveillance 2009. Data on industry-based exposure (e.g., occupational noise, heavy metals, and organic solvents and subject-specific health outcomes (e.g., audiometric examination were collected. Noise was measured as the daily 8-h time-weighted average level. Air conduction hearing thresholds were measured from 0.5 to 6 kHz, and pure-tone averages (PTA (i.e., means of 2, 3, and 4 kHz were computed. RESULTS: In the multivariate linear model, PTA increment with occupational noise were 1.64-fold and 2.15-fold higher in individuals exposed to heavy metals and organic solvents than in unexposed individuals, respectively. CONCLUSION: This study provides nationwide evidence that co-exposure to heavy metals and/or organic solvents may exacerbate the effect of noise exposure on hearing loss in workplaces. These findings suggest that workers in industries dealing with heavy metals or organic solvents are susceptible to such risks.

  9. Noise-induced hearing loss in Korean workers: co-exposure to organic solvents and heavy metals in nationwide industries.

    Science.gov (United States)

    Choi, Yoon-Hyeong; Kim, KyooSang

    2014-01-01

    Noise exposure is a well-known contributor to work-related hearing loss. Recent biological evidence suggests that exposure to ototoxic chemicals such as organic solvents and heavy metals may be additional contributors to hearing loss. However, in industrial settings, it is difficult to determine the risks of hearing loss due to these chemicals in workplaces accompanied by excessive noise exposure. A few studies suggest that the effect of noise may be enhanced by ototoxic chemicals. Therefore, this study investigated whether co-exposure to organic solvents and/or heavy metals in the workplace modifies the risk of noise exposure on hearing loss in a background of excessive noise. We examined 30,072 workers nationwide in a wide range of industries from the Korea National Occupational Health Surveillance 2009. Data on industry-based exposure (e.g., occupational noise, heavy metals, and organic solvents) and subject-specific health outcomes (e.g., audiometric examination) were collected. Noise was measured as the daily 8-h time-weighted average level. Air conduction hearing thresholds were measured from 0.5 to 6 kHz, and pure-tone averages (PTA) (i.e., means of 2, 3, and 4 kHz) were computed. In the multivariate linear model, PTA increment with occupational noise were 1.64-fold and 2.15-fold higher in individuals exposed to heavy metals and organic solvents than in unexposed individuals, respectively. This study provides nationwide evidence that co-exposure to heavy metals and/or organic solvents may exacerbate the effect of noise exposure on hearing loss in workplaces. These findings suggest that workers in industries dealing with heavy metals or organic solvents are susceptible to such risks.

  10. Noise-Induced Hearing Loss in Korean Workers: Co-Exposure to Organic Solvents and Heavy Metals in Nationwide Industries

    Science.gov (United States)

    Choi, Yoon-Hyeong; Kim, KyooSang

    2014-01-01

    Background Noise exposure is a well-known contributor to work-related hearing loss. Recent biological evidence suggests that exposure to ototoxic chemicals such as organic solvents and heavy metals may be additional contributors to hearing loss. However, in industrial settings, it is difficult to determine the risks of hearing loss due to these chemicals in workplaces accompanied by excessive noise exposure. A few studies suggest that the effect of noise may be enhanced by ototoxic chemicals. Therefore, this study investigated whether co-exposure to organic solvents and/or heavy metals in the workplace modifies the risk of noise exposure on hearing loss in a background of excessive noise. Methods We examined 30,072 workers nationwide in a wide range of industries from the Korea National Occupational Health Surveillance 2009. Data on industry-based exposure (e.g., occupational noise, heavy metals, and organic solvents) and subject-specific health outcomes (e.g., audiometric examination) were collected. Noise was measured as the daily 8-h time-weighted average level. Air conduction hearing thresholds were measured from 0.5 to 6 kHz, and pure-tone averages (PTA) (i.e., means of 2, 3, and 4 kHz) were computed. Results In the multivariate linear model, PTA increment with occupational noise were 1.64-fold and 2.15-fold higher in individuals exposed to heavy metals and organic solvents than in unexposed individuals, respectively. Conclusion This study provides nationwide evidence that co-exposure to heavy metals and/or organic solvents may exacerbate the effect of noise exposure on hearing loss in workplaces. These findings suggest that workers in industries dealing with heavy metals or organic solvents are susceptible to such risks. PMID:24870407

  11. Microvascular dysfunction with increased vascular leakage response in mice systemically exposed to arsenic.

    Science.gov (United States)

    Chen, Shih-Chieh; Huang, Shin-Yin; Lu, Chi-Yu; Hsu, Ya-Hung; Wang, Dean-Chuan

    2014-09-01

    The mechanisms underlying cardiovascular disease induced by arsenic exposure are not completely understood. The objectives of this study were to investigate whether arsenic-fed mice have an increased vascular leakage response to vasoactive agents and whether enhanced type-2 protein phosphatase (PP2A) activity is involved in mustard oil-induced leakage. ICR mice were fed water or sodium arsenite (20 mg/kg) for 4 or 8 weeks. The leakage response to vasoactive agents was quantified using the Evans blue (EB) technique or vascular labeling with carbon particles. Increased EB leakage and high density of carbon-labeled microvessels were detected in arsenic-fed mice treated with mustard oil. Histamine induced significantly higher vascular leakage in arsenic-fed mice than in water-fed mice. Pretreatment with the PP2A inhibitor okadaic acid or the neurokinin 1 receptor (NK1R) blocker RP67580 significantly reduced mustard oil-induced vascular leakage in arsenic-fed mice. The protein levels of PP2Ac and NK1R were similar in both groups. PP2A activity was significantly higher in the arsenic-fed mice compared with the control group. These findings indicate that microvessels generally respond to vasoactive agents, and that the increased PP2A activity is involved in mustard oil-induced vascular leakage in arsenic-fed mice. Arsenic may initiate endothelial dysfunction, resulting in vascular leakage in response to vasoactive agents.

  12. Practical Leakage-Resilient Symmetric Cryptography

    DEFF Research Database (Denmark)

    Faust, Sebastian; Pietrzak, Krzysztof; Schipper, Joachim

    2012-01-01

    Leakage resilient cryptography attempts to incorporate side-channel leakage into the black-box security model and designs cryptographic schemes that are provably secure within it. Informally, a scheme is leakage-resilient if it remains secure even if an adversary learns a bounded amount of arbitr......Leakage resilient cryptography attempts to incorporate side-channel leakage into the black-box security model and designs cryptographic schemes that are provably secure within it. Informally, a scheme is leakage-resilient if it remains secure even if an adversary learns a bounded amount...

  13. Ocorrência de perda auditiva induzida pelo ruído em carpinteiros Occurrence of noise induced hearing loss in carpenters

    Directory of Open Access Journals (Sweden)

    Victor Hygor Veríssimo Farias

    2012-06-01

    Full Text Available OBJETIVO: investigar a ocorrência de perda auditiva induzida pelo ruído (PAIR em carpinteiros, caracterizando a perda auditiva por faixa etária, tempo de exposição total ao ruído e uso regular de protetores auditivos durante o tempo total de exposição. MÉTODO: estudo retrospectivo, descritivo, em uma população de 80 carpinteiros da construção civil, atendidos em uma clínica particular. Foram analisados 60 trabalhadores, conforme dados obtidos na anamnese e ficha do exame audiométrico. RESULTADOS: 49% dos trabalhadores apresentaram audição normal, sendo 58% com limiares auditivos normais bilateralmente e 35% com entalhe audiométrico em 3 kHz, 4 kHz e/ou 6 kHz. 44% apresentaram perfil audiométrico sugestivo de PAIR, destes 74% foram classificados como PAIR bilateral e 19% como PAIR unilateral. Houve diferença estatística significante entre os grupo PAIR e Normal em relação às variáveis idade (p=0,001, assim como o tempo total de exposição ao ruído ocupacional (p=0,002. CONCLUSÃO: quanto maior a idade e o tempo de profissão como carpinteiro, maior é a sua alteração auditiva, principalmente, devido à exposição ao ruído elevado durante a jornada de trabalho, sendo também constatado que as medidas de controle pelo uso do protetor são insuficientes para prevenir perdas auditivas. Portanto, sugerem-se medidas preventivas em saúde auditiva ativamente nessa população estudada, no ramo da construção civil.PURPOSE: to investigate the occurrence of noise induced hearing loss in carpenters, characterizing the hearing loss for age group, time of total exposure to noise and regular use of hearing protectors during the total exposure time. METHOD: retrospective and descriptive study in a population of 80 construction carpenters, attended at a private clinic. 60 workers were analyzed, as data on medical history and record of audiometric testing. RESULTS: 49% of the workers shoed normal hearing, being 58% with normal

  14. Mutations in cockayne syndrome-associated genes (Csa and Csb) predispose to cisplatin-induced hearing loss in mice

    NARCIS (Netherlands)

    R.N. Rainey (Robert N.); S.-Y. Ng (Sum-Yan); J. Llamas (Juan); G.T.J. van der Horst (Gijsbertus); N. Segil (Neil)

    2016-01-01

    textabstractCisplatin is a common and effective chemotherapeutic agent, yet it often causes permanent hearing loss as a result of sensory hair cell death. The causes of sensitivity to DNA-damaging agents in nondividing cell populations, such as cochlear hair and supporting cells, are poorly

  15. Output capabilities of personal music players and assessment of preferred listening levels of test subjects: outlining recommendations for preventing music-induced hearing loss.

    Science.gov (United States)

    Breinbauer, Hayo A; Anabalón, Jose L; Gutierrez, Daniela; Cárcamo, Rodrigo; Olivares, Carla; Caro, Jorge

    2012-11-01

    Our goal was to assess the impact of personal music players, earphones, and music styles on output, the subject's preferred listening levels, and outline recommendations for the prevention of music-induced hearing loss. Experimental study. Personal music players' output capabilities and volunteers' preferred output levels were assessed in different settings. Based on current noise-induced hearing loss exposure limits, recommendations were outlined. On three different devices and earphone types and 10 music styles, free field equivalent sound pressure output levels were assessed by applying a microphone probe inside the auditory canal. Forty-five hearing-healthy volunteers were asked to select preferred listening levels in different background noise scenarios. Sound pressure output reached 126 dB. No difference was found between device types, whereas earbud and supra-aural earphones showed significantly lower outputs than in-ear earphones (P music style groups were identified with as much as 14.4 dB difference between them. In silence, 17.8% of volunteers spontaneously selected a listening level above 85 dB. With 90 dB background noise, 40% selected a level above 94 dB. Earphone attenuation capability was found to correlate significantly with preferred level reductions (r = 0.585, P < .001). In-ear and especially supra-aural earphones reduced preferred listening levels the most. Safe-use recommendations were outlined, whereas selecting the lowest volume setting comfortable remained the main suggestion. High background noise attenuating earphones may help in reducing comfortable listening levels and should be preferred. A risk table was elaborated, presenting time limits before reaching a risky exposure. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  16. Hearing Aids

    Science.gov (United States)

    ... listen to TV or your music player, play videogames, or use your phone. Talk to your audiologist ... your audiologist several times, but it's worth the benefit of being able to hear your friends and ...

  17. [Therapeutic effect of insulin-like growth factor-1 injection into the inner ears through scala tympani fenestration on gentamicin-induced hearing loss in guinea pigs].

    Science.gov (United States)

    Li, Yong-he; Chen, Hao; Guo, Meng-he

    2008-02-01

    To study the therapeutic effect of insulin-like growth factor-1 (IGF-1) injection into the inner ears through a scala tympani fenestration on sensorineural deafness in a guinea pig model of gentamicin-induced hearing loss. Twenty guinea pigs with gentamicin-induced hearing loss were randomized equally into IGF-1 group and control group. In both groups, scala tympani fenestration was performed for injection of IGF-1 (10 microl) or artificial perilymphatic fluid (10 microl). Auditory brainstem responses (ABR) test was performed before and 7 and 14 days after surgery, respectively, and the cochlea was removed by decollation of 3 guinea pigs from each group after ABR test for observing the changes in the hair cells using scanning electron microscope. Significant reduction in the ABR response threshold (RT) occurred in IGF-1 group 7 and 14 days after the surgery, and on day 14, ABR RT showed significant difference between IGF-1 group and the control group. Scanning electron microscopy revealed severer damages of the hair cells in the control group, and in the IGF-1 group, finger-like microvilli was detected on the surface of the damaged hair cells. IGF-1 injection in the inner ear through the scala tympani fenestration may ameliorate the damages of the auditory function and relieve sustained toxicity of gentamicin in guinea pigs possibly by protection and partial repair of the damaged cochlea hair cells as well as protection of the afferent nerves.

  18. Automation of unit for leakage test

    OpenAIRE

    LYCHKOVSKAYA V.S.; TSYGANKOV A.S.; GRINBERG G.M.; STANOVOVA O.A.

    2015-01-01

    Federal state educational standard requirements for training of university students have been considered. Leakage test procedures for components of aerospace vehicles have been described. Automation procedures of existing laboratory leakage test units have been outlined.

  19. Viral Causes of Hearing Loss: A Review for Hearing Health Professionals

    Science.gov (United States)

    Cohen, Brandon E.; Durstenfeld, Anne

    2014-01-01

    A number of viral infections can cause hearing loss. Hearing loss induced by these viruses can be congenital or acquired, unilateral or bilateral. Certain viral infections can directly damage inner ear structures, others can induce inflammatory responses which then cause this damage, and still others can increase susceptibility or bacterial or fungal infection, leading to hearing loss. Typically, virus-induced hearing loss is sensorineural, although conductive and mixed hearing losses can be seen following infection with certain viruses. Occasionally, recovery of hearing after these infections can occur spontaneously. Most importantly, some of these viral infections can be prevented or treated. For many of these viruses, guidelines for their treatment or prevention have recently been revised. In this review, we outline many of the viruses that cause hearing loss, their epidemiology, course, prevention, and treatment. PMID:25080364

  20. Safety and efficacy of ebselen for the prevention of noise-induced hearing loss: a randomised, double-blind, placebo-controlled, phase 2 trial.

    Science.gov (United States)

    Kil, Jonathan; Lobarinas, Edward; Spankovich, Christopher; Griffiths, Scott K; Antonelli, Patrick J; Lynch, Eric D; Le Prell, Colleen G

    2017-09-02

    Noise-induced hearing loss is a leading cause of occupational and recreational injury and disease, and a major determinant of age-related hearing loss. No therapeutic agent has been approved for the prevention or treatment of this disorder. In animal models, glutathione peroxidase 1 (GPx1) activity is reduced after acute noise exposure. Ebselen, a novel GPx1 mimic, has been shown to reduce both temporary and permanent noise-induced hearing loss in preclinical studies. We assessed the safety and efficacy of ebselen for the prevention of noise-induced hearing loss in young adults in a phase 2 clinical trial. In this single-centre, randomised, double-blind, placebo-controlled phase 2 trial, healthy adults aged 18-31 years were randomly assigned (1:1:1:1) at the University of Florida (Gainsville, FL, USA) to receive ebselen 200 mg, 400 mg, or 600 mg, or placebo orally twice daily for 4 days, beginning 2 days before a calibrated sound challenge (4 h of pre-recorded music delivered by insert earphones). Randomisation was done with an allocation sequence generated by an independent third party. The primary outcome was mean temporary threshold shift (TTS) at 4 kHz measured 15 min after the calibrated sound challenge by pure tone audiometry; a reduction of 50% in an ebselen dose group compared with the placebo group was judged to be clinically relevant. All participants who received the calibrated sound challenge and at least one dose of study drug were included in the efficacy analysis. All randomly assigned patients were included in the safety analysis. This trial is registered with ClinicalTrials.gov, number NCT01444846. Between Jan 11, 2013, and March 24, 2014, 83 participants were enrolled and randomly assigned to receive ebselen 200 mg (n=22), 400 mg (n=20), or 600 mg (n=21), or placebo (n=20). Two participants in the 200 mg ebselen group were discontinued from the study before the calibrated sound challenge because they no longer met the inclusion criteria; these

  1. Carbon leakage revisited. Unilateral climate policy under directed technical change

    International Nuclear Information System (INIS)

    Maria, Corrado Di; Van derWerf, E.

    2005-01-01

    This paper analyzes the consequences of unilateral climate policy in the presence of directed technical change. We develop a dynamic two-country model in which two otherwise identical countries differ in their environmental policy: one of the countries enforces a (binding) cap on emissions while the other does not. Focusing on carbon leakage, we show how, compared with a 'traditional' endogenous growth model, directed technical change will always lead to lower emissions in the unconstrained country. When clean and dirty goods are good substitutes, it may even be induced to reduce its emissions below the optimum level when both countries are unconstrained, so leakage is negative

  2. Issues behind Competitiveness and Carbon Leakage

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    This report explores the vulnerability of heavy industry to carbon leakage and competitiveness loss. It reviews the existing literature on competitiveness and carbon leakage under uneven climate policies. It also suggests a statistical method to track carbon leakage, and applies this methodology to Phase I of the EU emissions trading scheme, for various industrial activities: iron and steel, cement, aluminium and refineries. Finally, it reviews measures to mitigate carbon leakage, as discussed in Australia, Canada, Europe, New Zealand and the US.

  3. Subsea Hydraulic Leakage Detection and Diagnosis

    OpenAIRE

    Stavenes, Thomas

    2010-01-01

    The motivation for this thesis is reduction of hydraulic emissions, minimizing of process emergency shutdowns, exploitation of intervention capacity, and reduction of costs. Today, monitoring of hydraulic leakages is scarce and the main way to detect leakage is the constant need for filling of hydraulic fluid to the Hydraulic Power Unit (HPU). Leakage detection and diagnosis has potential, which would be adressed in this thesis. A strategy towards leakage detection and diagnosis is given....

  4. Simulation of leakage through mechanical sealing device

    Science.gov (United States)

    Tikhomorov, V. P.; Gorlenko, O. A.; Izmerov, M. A.

    2018-03-01

    The procedure of mathematical modeling of leakage through the mechanical seal taking into account waviness and roughness is considered. The percolation process is represented as the sum of leakages through a gap between wavy surfaces and percolation through gaps formed by fractal roughness, i.e. the total leakage is determined by the slot model and filtration leakage. Dependences of leaks on the contact pressure of corrugated and rough surfaces of the mechanical seal elements are presented.

  5. Heat exchanger leakage problem location

    Directory of Open Access Journals (Sweden)

    Jícha Miroslav

    2012-04-01

    Full Text Available Recent compact heat exchangers are very often assembled from numerous parts joined together to separate heat transfer fluids and to form the required heat exchanger arrangement. Therefore, the leak tightness is very important property of the compact heat exchangers. Although, the compact heat exchangers have been produced for many years, there are still technological problems associated with manufacturing of the ideal connection between the individual parts, mainly encountered with special purpose heat exchangers, e.g. gas turbine recuperators. This paper describes a procedure used to identify the leakage location inside the prime surface gas turbine recuperator. For this purpose, an analytical model of the leaky gas turbine recuperator was created to assess its performance. The results obtained are compared with the experimental data which were acquired during the recuperator thermal performance analysis. The differences between these two data sets are used to indicate possible leakage areas.

  6. Genetic Variation in POU4F3 and GRHL2 Associated with Noise-Induced Hearing Loss in Chinese Population: A Case-Control Study

    Directory of Open Access Journals (Sweden)

    Xiangrong Xu

    2016-06-01

    Full Text Available Noise-induced hearing loss (NIHL is an important occupational disease worldwide resulting from interactions between genetic and environmental factors. The purpose of this study was to examine whether genetic variations in POU4F3 and GRHL2 may influence susceptibility to NIHL in the Chinese population. A matched case-control study was carried out among 293 hearing loss individuals and 293 normal hearing workers drawn from a population of 3790 noise-exposed workers. Ten single-nucleotide polymorphisms (SNPs in POU4F3 and GRHL2 were selected and genotyped. Logistic regression was performed to analyze the main effects of SNPs and the interactions between noise exposure and SNPs. Moreover, the interactions between predictor haplotypes and noise exposure were also analyzed. Analysis revealed that the CC genotype of rs1981361 in the GRHL2 gene was associated with a higher risk of NIHL (adjusted OR = 1.59; 95% CI: 1.08–2.32, p = 0.018. Additionally, the GG genotype of rs3735715 in the GRHL2 gene was also a risk genotype (adjusted OR = 1.48; 95% CI: 1.01–2.19, p = 0.046. Significant interactions were found between rs3735715, rs1981361 (GRHL2, rs1368402 as well as rs891969 (POU4F3 and noise exposure in the high-level exposure groups. Furthermore, the protective haplotype CA in the POU4F3 gene and the risk haplotype GCCG in the GRHL2 gene were identified combined with noise exposure. These results indicated that GRHL2 might be an NIHL susceptibility gene, but the effect of POU4F3 on NIHL could only be detected when taking noise exposure into account, and their effects were enhanced by higher levels of noise exposure. However, the differences were not significant after the Bonferroni correction was applied. These results should be seen as suggestive.

  7. Aminoglycoside-induced and non-syndromic hearing loss is associated with the G7444A mutation in the mitochondrial COI/tRNASer(UCN) genes in two Chinese families

    International Nuclear Information System (INIS)

    Zhu Yi; Qian Yaping; Tang Xiaowen; Wang Jindan; Yang Li; Liao Zhisu; Li Ronghua; Ji Jinzhang; Li Zhiyuan; Chen Jianfu; Choo, Daniel I.; Lu Jianxin; Guan Minxin

    2006-01-01

    We report here the clinical, genetic, and molecular characterization of two Chinese families with aminoglycoside induced and non-syndromic hearing impairment. Clinical and genetic evaluations revealed the variable severity and age-of-onset in hearing impairment in these families. Strikingly, there were extremely low penetrances of hearing impairment in these Chinese families. Sequence analysis of the complete mitochondrial genomes in these pedigrees showed the distinct sets of mtDNA polymorphism, in addition to the identical G7444A mutation associated with hearing loss. Indeed, the G7444A mutation in the CO1 gene and the precursor of tRNA Ser(UCN) gene is present in homoplasmy only in the maternal lineage of those pedigrees but not other members of these families and 164 Chinese controls. Their mitochondrial genomes belong to the Eastern Asian haplogroups C5a and D4a, respectively. In fact, the occurrence of the G7444A mutation in these several genetically unrelated subjects affected by hearing impairment strongly indicates that this mutation is involved in the pathogenesis of hearing impairment. However, there was the absence of other functionally significant mtDNA mutations in two Chinese pedigrees carrying the G7444A mutation. Therefore, nuclear modifier gene(s) or aminoglycoside(s) may play a role in the phenotypic expression of the deafness-associated G7444A mutation in these Chinese pedigrees

  8. Water-soluble Coenzyme Q10 formulation (Q-ter) promotes outer hair cell survival in a guinea pig model of noise induced hearing loss (NIHL).

    Science.gov (United States)

    Fetoni, Anna Rita; Piacentini, Roberto; Fiorita, Antonella; Paludetti, Gaetano; Troiani, Diana

    2009-02-27

    The mitochondrial respiratory chain is a powerful source of reactive oxygen species (ROS) also in noise induced hearing loss (NIHL) and anti-oxidants and free-radicals scavengers have been shown to attenuate the damage. Coenzyme Q(10) (CoQ(10)) or ubiquinone has a bioenergetic role as a component of the mithocondrial respiratory chain, it inhibits mitochondrial lipid peroxidation, inducing ATP production and it is involved in ROS removal and prevention of oxidative stress-induced apoptosis. However the therapeutic application of CoQ(10) is limited by the lack of solubility and poor bio- availability, therefore it is a challenge to improve its water solubility in order to ameliorate the efficacy in tissues and fluids. This study was conducted in a model of acoustic trauma in the guinea pig where the effectiveness of CoQ(10) was compared with a soluble formulation of CoQ(10) (multicomposite CoQ(10) Terclatrate, Q-ter) given intraperitoneally 1 h before and once daily for 3 days after pure tone noise exposure (6 kHz for 1 h at 120 dB SPL). Functional and morphological studies were carried out by measuring auditory brainstem responses, scanning electron microscopy for hair cell loss count, active caspase 3 staining and terminal deoxynucleotidyl transferase-mediated dUTP labelling assay in order to identify initial signs of apoptosis. Treatments decreased active caspase 3 expression and the number of apoptotic cells, but animals injected with Q-ter showed a greater degree of activity in preventing apoptosis and thus in improving hearing. These data confirm that solubility of Coenzyme Q(10) improves the ability of CoQ(10) in preventing oxidative injuries that result from mitochondrial dysfunction.

  9. Protective effect of unilateral and bilateral ear plugs on noise-induced hearing loss: Functional and morphological evaluation in animal model

    Directory of Open Access Journals (Sweden)

    Dong-Kee Kim

    2014-01-01

    Full Text Available The aim of the following study is to evaluate immediate protective effect of ear plug from noise morphologically and functionally. An 1-month aged 29 male C57BL/6 mice. Subjects were divided into four groups as normal control(G1, bilaterally plugged group (G2, unilaterally plugged group (G3 and noise control group (G4 and later 3 groups were exposed to 110 sound pressure level white noise for 60 min. Immediately after noise exposure, audiologic tests were performed and cochlear morphology and expression levels of a-synuclein in the cochlea were investigated. There were no functional changes in G2 and plugged ears of G3 after noise exposure, whereas unplugged ears of G3 and G4 showed significant hearing loss. In morphological study, there were a significant degeneration of the organ of Corti and mean number and diameter of efferent buttons, in unplugged ears of G3 and G4. Plugged ears of G3 also showed mild changes in morphological study. Reduction of a-synuclein was observed at the efferent terminals or cochlear extracts after noise exposure. The protective effect of ear plug on noise exposure was proven morphologically and functionally in the animal model of noise-induced hearing loss. Further study on cellular or ultrastructural level with ear plug will be needed to reveal more precise mechanism.

  10. Bioconversion of Scutellaria baicalensis extract can increase recovery of auditory function in a mouse model of noise-induced hearing loss.

    Science.gov (United States)

    Rodriguez, Isabel; Hong, Bin Na; Nam, Youn Hee; Kim, Eun Young; Park, Geun Ha; Ji, Min Gun; Kang, Tong Ho

    2017-09-01

    In noise-induced hearing loss (NIHL), noise exposure damages cochlear sensory hair cells, which lack the capacity to regenerate. Following noise insult, intense metabolic activity occurs, resulting in a cochlear free radical imbalance. Oxidative stress and antioxidant enzyme alterations, including lipoxygenase upregulation, have been linked to chronic inflammation, which contributes to hearing impairment. We previously proposed Scutellaria baicalensis (SB) extract as an alternative therapeutic for preventing NIHL and attributed its pharmacological effects to baicalein. Although baicalein was most effective, its concentration in SB extract is much lower compared to baicalin. In this study, we performed enzymatic bioconversion using an Sumizyme (SM) enzyme to increase baicalein concentration in SB extract and consequently improve its therapeutic efficacy. HPLC analysis revealed that baicalein concentration in SB extract after bioconversion (BSB) was significantly increased. Moreover, BSB-treated mice exhibited significantly improved auditory function compared with control mice and tended to have improved auditory function compared with SB-treated mice. We also demonstrated that BSB effectively stimulates hair cell regeneration compared to SB that did not achieve the same effect in a zebrafish model. Finally, when compared the abilities of SB and BSB to inhibit lipoxygenase (LOX), BSB showed a greater efficacy. Cumulatively, our data suggest that BSB exhibits improved pharmacological properties for treating NIHL compared with SB. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  11. A functional Ser326Cys polymorphism in hOGG1 is associated with noise-induced hearing loss in a Chinese population.

    Directory of Open Access Journals (Sweden)

    Huanxi Shen

    Full Text Available DNA damage to cochlear hair cells caused by 8-oxoguanine (8-oxoG is essential for the development of noise-induced hearing loss (NIHL. Human 8-oxoG DNA glycosylase1 (hOGG1 is a key enzyme in the base excision repair (BER pathway that eliminates 8-oxoG. Many epidemiological and functional studies have suggested that the hOGG1 Ser326Cys polymorphism (rs1052133 is associated with many diseases. The purpose of this investigation was to investigate whether the hOGG1 Ser326Cys polymorphism in the human BER pathway is associated with genetic susceptibility to NIHL in a Chinese population. This polymorphism was genotyped among 612 workers with NIHL and 615 workers with normal hearing. We found that individuals with the hOGG1 Cys/Cys genotype had a statistically significantly increased risk of NIHL compared with those who carried the hOGG1 Ser/Ser genotype (adjusted OR=1.59, 95% CI=1.13-2.25 and this increased risk was more pronounced among the workers in the 15- to 25- and >25-year noise exposure time, 85-92 dB(A noise exposure level, ever smoking, and ever drinking groups, similar effects were also observed in a recessive model. In summary, our data suggested that the hOGG1 Cys/Cys genotype may be a genetic susceptibility marker for NIHL in the Chinese Han population.

  12. Association of Behavior With Noise-Induced Hearing Loss Among Attendees of an Outdoor Music Festival: A Secondary Analysis of a Randomized Clinical Trial.

    Science.gov (United States)

    Kraaijenga, Véronique J C; van Munster, J J C M; van Zanten, G A

    2018-06-01

    To date, factors associated with noise-induced hearing loss at music festivals have not yet been analyzed in a single comprehensive data set. In addition, little is known about the hearing loss-associated behavior of music festival attendees. To assess which factors are associated with the occurrence of a temporary threshold shift (TTS) after music exposure and to investigate the behavior of music festival attendees. This prospective post hoc analysis gathered data from a randomized, single-blind clinical trial conducted on September 5, 2015, at an outdoor music festival in Amsterdam, the Netherlands. Adult volunteers with normal hearing were recruited via social media from August 26 through September 3, 2015. Intention to use earplugs was an exclusion criterion. Of 86 volunteers assessed, 51 were included. This post hoc analysis was performed from October 3, 2016, through February 27, 2017. Music festival visit for 4.5 hours. The primary outcome was a TTS on a standard audiogram for the frequencies 3.0- and 4.0-kHz. Multivariable linear regression was performed to determine which factors are associated with a TTS. A questionnaire on behavior, hearing, and tinnitus was distributed to the participants before and after the festival visit. A total of 51 participants were included (18 men [35%] and 33 women [65%]) with a mean (SD) age of 27 (6) years. Mean (SD) threshold change across 3.0 and 4.0 kHz was 5.4 (5.7) dB for the right ear and 4.0 (6.1) dB for the left ear. Earplug use (absolute difference in the left ear, -6.0 dB [95% CI, -8.7 to -3.2 dB]; in the right ear, -6.4 dB [95% CI, -8.8 to -4.1 dB]), quantity of alcohol use (absolute difference per unit in the left ear, 1.1 dB [95% CI, 0.5 to 1.7 dB]; in the right ear, 0.7 dB [95% CI, 0.1 to 1.4 dB]), drug use (absolute difference in the right ear, 6.0 dB [95% CI, 0.9 to 11.1 dB]), and male sex (absolute difference in the right ear, 4.1 dB [95% CI, 0.3 to 5.9 dB]) were independently associated with hearing loss

  13. Does hearing aid use affect audiovisual integration in mild hearing impairment?

    Science.gov (United States)

    Gieseler, Anja; Tahden, Maike A S; Thiel, Christiane M; Colonius, Hans

    2018-04-01

    There is converging evidence for altered audiovisual integration abilities in hearing-impaired individuals and those with profound hearing loss who are provided with cochlear implants, compared to normal-hearing adults. Still, little is known on the effects of hearing aid use on audiovisual integration in mild hearing loss, although this constitutes one of the most prevalent conditions in the elderly and, yet, often remains untreated in its early stages. This study investigated differences in the strength of audiovisual integration between elderly hearing aid users and those with the same degree of mild hearing loss who were not using hearing aids, the non-users, by measuring their susceptibility to the sound-induced flash illusion. We also explored the corresponding window of integration by varying the stimulus onset asynchronies. To examine general group differences that are not attributable to specific hearing aid settings but rather reflect overall changes associated with habitual hearing aid use, the group of hearing aid users was tested unaided while individually controlling for audibility. We found greater audiovisual integration together with a wider window of integration in hearing aid users compared to their age-matched untreated peers. Signal detection analyses indicate that a change in perceptual sensitivity as well as in bias may underlie the observed effects. Our results and comparisons with other studies in normal-hearing older adults suggest that both mild hearing impairment and hearing aid use seem to affect audiovisual integration, possibly in the sense that hearing aid use may reverse the effects of hearing loss on audiovisual integration. We suggest that these findings may be particularly important for auditory rehabilitation and call for a longitudinal study.

  14. Murine CMV-Induced Hearing Loss Is Associated with Inner Ear Inflammation and Loss of Spiral Ganglia Neurons

    OpenAIRE

    Bradford, Russell D.; Yoo, Young-Gun; Golemac, Mijo; Pugel, Ester Pernjak; Jonjic, Stipan; Britt, William J.

    2015-01-01

    Author Summary Congenital infection with human cytomegalovirus (HCMV) is the most common viral infection of the fetus and occurs in 0.5?2.0% of all live births in most regions in the world. Infection of the fetus can result in a spectrum of end-organ disease, including long term damage to the central nervous system (CNS). Although less than 10% of infected infants exhibit clinical evidence of end-organ disease, up to 10% of the total number of infected infants develop hearing loss. Mechanisms...

  15. Occupational hearing loss in Korea.

    Science.gov (United States)

    Kim, Kyoo Sang

    2010-12-01

    In this article, current status of noise exposure in workplaces, trend of workers with noise-induced hearing loss (NIHL), and prevalence of NIHL in workers by industry and job category in Korea were reviewed. In addition, trends of research on the audiological effects such as hearing loss from noise and occupational hearing loss from non-noise in Korea were addressed through reports in industrial audiology. Though noise exposure level has improved, noise still shows the highest rate of cases exceeding exposure limit among workplace hazards. NIHL is the most common occupational disease except work-related disease such as musculoskeletal disorders and cerebrovascular diseases, and NIHL prevalence is thought to be much higher than reported in official publications. Noise affecting hearing comes from various sources such as workplaces, military settings, areas with exposure to high noise, and specific noise sources. There is also occupational hearing loss by non-noise including chemicals such as organic solvents and heavy metals, barotrauma, and trauma due to welding spark. Noise affects daily life through audiological effects such as hearing loss and tinnitus, non-audiological physical effects (e.g., cardiovascular), and psychosocial and behavioral effects. Development of systematic and comprehensive hearing conservation programs for lowering the noise level in workplaces and preventing the NIHL, and preparation of technological, administrative system for its settlement at workplace are urgently needed.

  16. Duration of works, flight hours, and blood pressure related to noise-induced hearing loss among Indonesian Air Force helicopter pilots

    Directory of Open Access Journals (Sweden)

    Kholidah Hanum

    2006-09-01

    Full Text Available Helicopter pilots exposed to high intensity noise and other risk factors had increased risk to be noise-induced hearing loss (NIHL. Therefore, it is beneficial to study several risk factors related to NIHL. This study was a nested case-control. Data was extracted from available medical records among helicopter pilots who performed routine aerophysiology training indoctrination (ILA during 1980 through March 2004 at Saryanto Institute for Aviation and Aerospace Medicine (Lakespra, Jakarta. Case was those who had audiogram with a notch of 40 dB or more and of 4000 Hertz on one site or bilateral ears. A case was matched by two controls who free from NIHL up to 2004. All risk factors for cases and controls were counted as of reference date of cases diagnosed. There were 187 medical records available for this study. A number of 32 cases and 64 controls were identified. The final model reveals that NIHL was related to total duration of works, flight hours, and blood pressure. Those who had 500 hours or more than less 500 hours had a moderate increased risk for 2.5 to be NIHL [Adjusted odds ratio (ORa= 2.50; 95% confidence intervals (CI = 0.66-9.29; p = 0.180]. Those who had total duration works 11-24 years had a moderate increased to be NIHL for 2.7 times (ORa = 2.71; 95% CI=0.90-8.10; p = 0.075. Furthermore, prehypertension and hypertension stage 1 subjects than normal blood pressure had moderate trend increased risk to be NIHL. In conclusion total flight hours for 500 hours or more, total duration works 11-24 years, or prehypertension and hypertension stage 1 increased risk NIHL. (Med J Indones 2006; 15:185-90 Keywords: noise induced hearing loss, flight hours, working duration, blood pressure

  17. Hearing in young adults. Part I: The effects of attitudes and beliefs toward noise, hearing loss, and hearing protector devices

    Directory of Open Access Journals (Sweden)

    Hannah Keppler

    2015-01-01

    Full Text Available There is great concern regarding the development of noise-induced hearing loss (NIHL in youth caused by high sound levels during various leisure activities. Health-orientated behavior of young adults might be linked to the beliefs and attitudes toward noise, hearing loss, and hearing protector devices (HPDs. The objective of the current study was to evaluate the effects of attitudes and beliefs toward noise, hearing loss, and HPDs on young adults′ hearing status. A questionnaire and an audiological test battery were completed by 163 subjects (aged 18-30 years. The questionnaire contained the Youth Attitude to Noise Scale (YANS and Beliefs about Hearing Protection and Hearing Loss (BAHPHL. A more positive attitude or belief represented an attitude where noise or hearing loss is seen as unproblematic and attitudes and beliefs regarding HPDs is worse. Hearing was evaluated using (high frequency pure tone audiometry (PTA, transient evoked and distortion product otoacoustic emissions. First, mean differences in hearing between the groups with different attitudes and beliefs were evaluated using one-way analysis of variance (ANOVA. Second, a χ2 test was used to examine the usage of HPDs by the different groups with different attitudes and beliefs. Young adults with a positive attitude had significantly more deteriorated hearing and used HPDs less than the other subjects. Hearing conservation programs (HCPs for young adults should provide information and knowledge regarding noise, hearing loss, and HPDs. Barriers wearing HPDs should especially be discussed. Further, those campaigns should focus on self-experienced hearing related symptoms that might serve as triggers for attitudinal and behavioral changes.

  18. Cochlin-tomoprotein (CTP) detection test identified perilymph leakage preoperatively in revision stapes surgery.

    Science.gov (United States)

    Kataoka, Yuko; Ikezono, Tetsuo; Fukushima, Kunihiro; Yuen, Koji; Maeda, Yukihide; Sugaya, Akiko; Nishizaki, Kazunori

    2013-08-01

    Perilymphatic fistula (PLF) is defined as an abnormal leakage between perilymph from the labyrinth to the middle ear. Symptoms include hearing loss, tinnitus, and vertigo. The standard mode of PLF detection is intraoperative visualization of perilymph leakage and fistula, which ostensibly confirms the existence of PLF. Other possible methods of diagnosis include confirmation of pneumolabyrinth via diagnostic imaging. Recently, a cochlin-tomoprotein (CTP) detection test has been developed that allows definitive diagnosis of PLF-related hearing loss. We report the case of a 45-year-old man who presented with right-sided tinnitus, hearing loss, and dizziness 30 years after stapes surgery. Middle ear lavage was performed after myringotomy. A preoperative diagnosis of PLF was reached using the CTP detection test. Intraoperative observations included a necrotic long process of the incus, displaced wire piston, and fibrous tissue in the oval window. Perilymph leakage was not evident. The oval window was closed with fascia, and vertigo disappeared within 2 weeks postoperatively. When PLF is suspected after stapes surgery, the CTP detection test can be a useful, highly sensitive, and less invasive method for preoperative diagnosis. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  19. Why the CDM can reduce carbon leakage

    International Nuclear Information System (INIS)

    Kallbekken, S.

    2006-04-01

    Carbon leakage is an important concern because it can reduce the environmental effectiveness of the Kyoto Protocol. The Clean Development Mechanism, one of the flexibility mechanisms allowed under the protocol, has the potential to reduce carbon leakage significantly because it reduces the relative competitive disadvantage to Annex B countries of restricting greenhouse gas emissions. The economic intuition behind this mechanism is explored in a theoretical analysis. It is then analyzed numerically using a CGE model. The results indicate that, assuming appropriate accounting for leakage and under realistic assumptions on CDM activity, the CDM has the potential to reduce the magnitude of carbon leakage by around three fifths

  20. The impact of hearing impairment and noise-induced hearing injury on quality of life in the active-duty military population: challenges to the study of this issue.

    Science.gov (United States)

    Alamgir, Hasanat; Turner, Caryn A; Wong, Nicole J; Cooper, Sharon P; Betancourt, Jose A; Henry, James; Senchak, Andrew J; Hammill, Tanisha L; Packer, Mark D

    2016-01-01

    The objectives of this research were to 1) summarize the available evidence on the impact of hearing loss on quality of life (QOL) among U.S. active-duty service members, 2) describe the QOL instruments that have been used to quantify the impact of hearing loss on quality of life, 3) examine national population-level secondary databases and report on their utility for studying the impact of hearing loss on QOL among active-duty service members, and 4) provide recommendations for future studies that seek to quantify the impact of hearing loss in this population. There is a lack of literature that addresses the intersection of hearing impairment, the military population, and quality of life measures. For audiological research, U.S. military personnel offer a unique research population, as they are exposed to noise levels and blast environments that are highly unusual in civilian work settings and can serve as a model population for studying the impact on QOL associated with these conditions. Our team recommends conducting a study on the active-duty service member population using a measurement instrument suitable for determining decreases in QOL specifically due to hearing loss.

  1. Valve packing leakage monitoring device

    International Nuclear Information System (INIS)

    Ezekoye, L.I.

    1985-01-01

    A device for monitoring leakage of fluid across a seal in a component connected to a pressurized fluid system including a housing having a chamber with an inlet for receiving fluid leaking across the seal and an outlet. A positioning means is connected to an orifice plug so as to move the plug for permitting the fluid to be discharged through the orifice at the same rate at which it enters the first chamber and means for detecting the movement of the plug is provided to produce and output signal corresponding to the distance moved by the plug and thereby indicate flow rate. The positioning means compromise a piston attached to the plug by a hollow tube and springs, which at low flow rates locate the piston. When flow increases sufficiently pressure increases and urges the piston upwards. A magnetic portion of tube actuates a succession of proximity switches to indicate flow rate. (author)

  2. Predictors of Hearing Protection Use in Construction Workers

    OpenAIRE

    Edelson, Jane; Neitzel, Richard; Meischke, Hendrika; Daniell, William; Sheppard, Lianne; Stover, Bert; Seixas, Noah

    2009-01-01

    Objectives: Although noise-induced hearing loss is completely preventable, it remains highly prevalent among construction workers. Hearing protection devices (HPDs) are commonly relied upon for exposure reduction in construction, but their use is complicated by intermittent and highly variable noise, inadequate industry support for hearing conservation, and lax regulatory enforcement.

  3. Hearing status in patients with rheumatoid arthritis.

    Science.gov (United States)

    Ahmadzadeh, A; Daraei, M; Jalessi, M; Peyvandi, A A; Amini, E; Ranjbar, L A; Daneshi, A

    2017-10-01

    Rheumatoid arthritis is thought to induce conductive hearing loss and/or sensorineural hearing loss. This study evaluated the function of the middle ear and cochlea, and the related factors. Pure tone audiometry, speech reception thresholds, speech discrimination scores, tympanometry, acoustic reflexes, and distortion product otoacoustic emissions were assessed in rheumatoid arthritis patients and healthy volunteers. Pure tone audiometry results revealed a higher bone conduction threshold in the rheumatoid arthritis group, but there was no significant difference when evaluated according to the sensorineural hearing loss definition. Distortion product otoacoustic emissions related prevalence of conductive or mixed hearing loss, tympanometry values, acoustic reflexes, and speech discrimination scores were not significantly different between the two groups. Sensorineural hearing loss was significantly more prevalent in patients who used azathioprine, cyclosporine and etanercept. Higher bone conduction thresholds in some frequencies were detected in rheumatoid arthritis patients that were not clinically significant. Sensorineural hearing loss is significantly more prevalent in refractory rheumatoid arthritis patients.

  4. A single dose of dexamethasone encapsulated in polyethylene glycol-coated polylactic acid nanoparticles attenuates cisplatin-induced hearing loss following round window membrane administration.

    Science.gov (United States)

    Sun, Changling; Wang, Xueling; Zheng, Zhaozhu; Chen, Dongye; Wang, Xiaoqin; Shi, Fuxin; Yu, Dehong; Wu, Hao

    2015-01-01

    This study aimed to investigate the sustained drug release properties and hearing protection effect of polyethylene glycol-coated polylactic acid (PEG-PLA) stealth nanoparticles loaded with dexamethasone (DEX). DEX was fabricated into PEG-PLA nanoparticles using an emulsion and evaporation technique, as previously reported. The DEX-loaded PEG-PLA nanoparticles (DEX-NPs) had a hydrodynamic diameter of 130±4.78 nm, and a zeta potential of -26.13±3.28 mV. The in vitro release of DEX from DEX-NPs lasted 24 days in phosphate buffered saline (pH 7.4), 5 days in artificial perilymph (pH 7.4), and 1 day in rat plasma. Coumarin 6-labeled NPs placed onto the round window membrane (RWM) of guinea pigs penetrated RWM quickly and accumulated to the organs of Corti, stria vascularis, and spiral ganglion cells after 1 hour of administration. The DEX-NPs locally applied onto the RWM of guinea pigs by a single-dose administration continuously released DEX in 48 hours, which was significantly longer than the free DEX that was cleared out within 12 hours after administration at the same dose. Further functional studies showed that locally administrated single-dose DEX-NPs effectively preserved outer hair cells in guinea pigs after cisplatin insult and thus significantly attenuated hearing loss at 4 kHz and 8 kHz frequencies when compared to the control of free DEX formulation. Histological analyses indicated that the administration of DEX-NPs did not induce local inflammatory responses. Therefore, prolonged delivery of DEX by PEG-PLA nanoparticles through local RWM diffusion (administration) significantly protected the hair cells and auditory function in guinea pigs from cisplatin toxicity, as determined at both histological and functional levels, suggesting the potential therapeutic benefits in clinical applications.

  5. Forest Carbon Leakage Quantification Methods and Their Suitability for Assessing Leakage in REDD

    Directory of Open Access Journals (Sweden)

    Sabine Henders

    2012-01-01

    Full Text Available This paper assesses quantification methods for carbon leakage from forestry activities for their suitability in leakage accounting in a future Reducing Emissions from Deforestation and Forest Degradation (REDD mechanism. To that end, we first conducted a literature review to identify specific pre-requisites for leakage assessment in REDD. We then analyzed a total of 34 quantification methods for leakage emissions from the Clean Development Mechanism (CDM, the Verified Carbon Standard (VCS, the Climate Action Reserve (CAR, the CarbonFix Standard (CFS, and from scientific literature sources. We screened these methods for the leakage aspects they address in terms of leakage type, tools used for quantification and the geographical scale covered. Results show that leakage methods can be grouped into nine main methodological approaches, six of which could fulfill the recommended REDD leakage requirements if approaches for primary and secondary leakage are combined. The majority of methods assessed, address either primary or secondary leakage; the former mostly on a local or regional and the latter on national scale. The VCS is found to be the only carbon accounting standard at present to fulfill all leakage quantification requisites in REDD. However, a lack of accounting methods was identified for international leakage, which was addressed by only two methods, both from scientific literature.

  6. Measurements on Hearing

    DEFF Research Database (Denmark)

    Poulsen, Torben

    1996-01-01

    Background material for measurements of hearing for grammar school pupils. The note gives the necessary background for the exercise 'Measurement on Hearing'. The topics comprise sound and decibel, the ear, basic psychoacoustics, hearing threshold, audiometric measurement methods, speech and speech...

  7. Hearing Disorders and Deafness

    Science.gov (United States)

    ... enough to enjoy talking with friends or family. Hearing disorders make it hard, but not impossible, to ... often be helped. Deafness can keep you from hearing sound at all. What causes hearing loss? Some ...

  8. Study on the annular leakage-flow-induced vibrations. 2nd Report. Stability analysis and experiments for translationally and rotationally coupled two-degree-of-freedom systems; Kanjo sukimaryu reiki shindo ni kansuru kenkyu. 2. heishin kaiten 2 jiyudo renseikei no anteisei kaiseki oyobi jikken

    Energy Technology Data Exchange (ETDEWEB)

    Li, D.W. [Hitachi, Ltd., Tokyo (Japan); Kaneko, S. [The University of Tokyo, Tokyo (Japan); Hayama, S. [Toyama Prefectural University, Toyama (Japan)

    1999-07-25

    In this study, the stability of annular leakage-flow-induced vibrations was investigated theoretically and experimentally for a translationally and rotationally coupled two-degree-of-freedom system. The critical flow rate was both theoretically and experimentally obtained as a function of the passage increment ratio and the eccentricity of the passage. A good agreement between the theoretical and experimental results was obtained. It was discovered both theoretically and from the experiments that instability will occur in the case of a divergent passage: the eccentricity of the passage lowers the stability of the systems. (author)

  9. Changes in auditory perceptions and cortex resulting from hearing recovery after extended congenital unilateral hearing loss

    Directory of Open Access Journals (Sweden)

    Jill B Firszt

    2013-12-01

    Full Text Available Monaural hearing induces auditory system reorganization. Imbalanced input also degrades time-intensity cues for sound localization and signal segregation for listening in noise. While there have been studies of bilateral auditory deprivation and later hearing restoration (e.g. cochlear implants, less is known about unilateral auditory deprivation and subsequent hearing improvement. We investigated effects of long-term congenital unilateral hearing loss on localization, speech understanding, and cortical organization following hearing recovery. Hearing in the congenitally affected ear of a 41 year old female improved significantly after stapedotomy and reconstruction. Pre-operative hearing threshold levels showed unilateral, mixed, moderately-severe to profound hearing loss. The contralateral ear had hearing threshold levels within normal limits. Testing was completed prior to, and three and nine months after surgery. Measurements were of sound localization with intensity-roved stimuli and speech recognition in various noise conditions. We also evoked magnetic resonance signals with monaural stimulation to the unaffected ear. Activation magnitudes were determined in core, belt, and parabelt auditory cortex regions via an interrupted single event design. Hearing improvement following 40 years of congenital unilateral hearing loss resulted in substantially improved sound localization and speech recognition in noise. Auditory cortex also reorganized. Contralateral auditory cortex responses were increased after hearing recovery and the extent of activated cortex was bilateral, including a greater portion of the posterior superior temporal plane. Thus, prolonged predominant monaural stimulation did not prevent auditory system changes consequent to restored binaural hearing. Results support future research of unilateral auditory deprivation effects and plasticity, with consideration for length of deprivation, age at hearing correction, degree and type

  10. Radiofrequency radiation leakage from microwave ovens

    International Nuclear Information System (INIS)

    Lahham, A.; Sharabati, A.

    2013-01-01

    This work presents data on the amount of radiation leakage from 117 microwave ovens in domestic and restaurant use in the West Bank, Palestine. The study of leakage is based on the measurements of radiation emissions from the oven in real-life conditions by using a frequency selective field strength measuring system. The power density from individual ovens was measured at a distance of 1 m and at the height of centre of door screen. The tested ovens were of different types, models with operating powers between 1000 and 1600 W and ages ranging from 1 month to >20 y, including 16 ovens with unknown ages. The amount of radiation leakage at a distance of 1 m was found to vary from 0.43 to 16.4 μW cm -1 with an average value equalling 3.64 μW cm -2 . Leakages from all tested microwave ovens except for seven ovens (∼6 % of the total) were below 10 μW cm -2 . The highest radiation leakage from any tested oven was ∼16.4 μW cm -2 , and found in two cases only. In no case did the leakage exceed the limit of 1 μWcm -1 recommended by the ICNIRP for 2.45-GHz radiofrequency. This study confirms a linear correlation between the amount of leakage and both oven age and operating power, with a stronger dependence of leakage on age. (authors)

  11. Leakage-resilient cryptography from minimal assumptions

    DEFF Research Database (Denmark)

    Hazay, Carmit; López-Alt, Adriana; Wee, Hoeteck

    2013-01-01

    We present new constructions of leakage-resilient cryptosystems, which remain provably secure even if the attacker learns some arbitrary partial information about their internal secret key. For any polynomial ℓ, we can instantiate these schemes so as to tolerate up to ℓ bits of leakage. While the...

  12. Predicting Envelope Leakage in Attached Dwellings

    Energy Technology Data Exchange (ETDEWEB)

    Faakye, O. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Arena, L. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Griffiths, D. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States)

    2013-07-01

    The most common method for measuring air leakage is to use a single blower door to pressurize and/or depressurize the test unit. In detached housing, the test unit is the entire home and the single blower door measures air leakage to the outside. In attached housing, this 'single unit', 'total', or 'solo' test method measures both the air leakage between adjacent units through common surfaces as well air leakage to the outside. Measuring and minimizing this total leakage is recommended to avoid indoor air quality issues between units, reduce energy losses to the outside, reduce pressure differentials between units, and control stack effect. However, two significant limitations of the total leakage measurement in attached housing are: for retrofit work, if total leakage is assumed to be all to the outside, the energy benefits of air sealing can be significantly over predicted; for new construction, the total leakage values may result in failing to meet an energy-based house tightness program criterion. The scope of this research is to investigate an approach for developing a viable simplified algorithm that can be used by contractors to assess energy efficiency program qualification and/or compliance based upon solo test results.

  13. [Study the impacts of diagnosis on occupational noise-induced deafness after bring into the different high frequency hearing threshold weighted value].

    Science.gov (United States)

    Xue, L J; Yang, A C; Chen, H; Huang, W X; Guo, J J; Liang, X Y; Chen, Z Q; Zheng, Q L

    2017-11-20

    Objective: Study of the results and the degree on occupational noise-induced deafness in-to the different high frequency hearing threshold weighted value, in order to provide theoretical basis for the re-vision of diagnostic criteria on occupational noise-induced deafness. Methods: A retrospective study was con-ducted to investigate the cases on the diagnosis of occupational noise-induced deafness in Guangdong province hospital for occupational disease prevention and treatment from January 2016 to January 2017. Based on the re-sults of the 3 hearing test for each test interval greater than 3 days in the hospital, the best threshold of each frequency was obtained, and based on the diagnostic criteria of occupational noise deafness in 2007 edition, Chi square test, t test and variance analysis were used to measure SPSS21.0 data, their differences are tested among the means of speech frequency and the high frequency weighted value into different age group, noise ex-posure group, and diagnostic classification between different dimensions. Results: 1. There were totally 168 cases in accordance with the study plan, male 154 cases, female 14 cases, the average age was 41.18 ±6.07 years old. 2. The diagnosis rate was increased into the weighted value of different high frequency than the mean value of pure speech frequency, the weighted 4 kHz frequency increased by 13.69% (χ(2)=9.880, P =0.002) , 6 kHz increased by 15.47% (χ(2)=9.985, P =0.002) and 4 kHz+6 kHz increased by15.47% (χ(2)=9.985, P =0.002) , the difference was statistically significant. The diagnostic rate of different high threshold had no obvious differ-ence between the genders. 3. The age groups were divided into less than or equal to 40years old group (A group) and 40-50 years old group (group B) , there were higher the diagnostic rate between high frequency weighted 4 kHz (A group χ(2)=3.380, P =0.050; B group χ(2)=4.054, P =0.032) , weighted 6 kHz (A group χ(2)=6.362, P =0.012; B group χ(2

  14. Advances in the neurobiology of hearing disorders : Recent developments regarding the basis of tinnitus and hyperacusis

    NARCIS (Netherlands)

    Knipper, Marlies; Van Dijk, Pim; Nunes, Isidro; Rüttiger, Lukas; Zimmermann, Ulrike

    2013-01-01

    The prevalence of hearing problems in the Western world has, due to aging of the population, doubled over the past 30 years. Thereby, noise-induced hearing loss is an important factor that worsens over time in addition to age-related hearing loss. Hearing loss is usually measured as an elevation of

  15. Noise-Induced Hearing Loss - A Preventable Disease? Results of a 10-Year Longitudinal Study of Workers Exposed to Occupational Noise.

    Science.gov (United States)

    Frederiksen, Thomas W; Ramlau-Hansen, Cecilia H; Stokholm, Zara A; Grynderup, Matias B; Hansen, Åse M; Kristiansen, Jesper; Vestergaard, Jesper M; Bonde, Jens P; Kolstad, Henrik A

    2017-01-01

    To survey current, Danish industrial noise levels and the use of hearing protection devices (HPD) over a 10-year period and to characterise the association between occupational noise and hearing threshold shift in the same period. Furthermore, the risk of hearing loss among the baseline and the follow-up populations according to first year of occupational noise exposure is evaluated. In 2001-2003, we conducted a baseline survey of noise- and hearing-related disorders in 11 industries with suspected high noise levels. In 2009-2010, we were able to follow up on 271 out of the 554 baseline workers (49%). Mean noise levels per industry and self-reported HPD use are described at baseline and follow-up. The association between cumulative occupational noise exposure and hearing threshold shift over the 10-year period was assessed using linear regression, and the risk of hearing loss according to year of first occupational noise exposure was evaluated with logistic regression. Over the 10-year period, mean noise levels declined from 83.9 dB(A) to 82.8 dB(A), and for workers exposed >85 dB(A), the use of HPD increased from 70.1 to 76.1%. We found a weak, statistically insignificant, inverse association between higher ambient cumulative noise exposure and poorer hearing (-0.10 dB hearing threshold shift per dB-year (95% confidence interval (CI): -0.36; 0.16)). The risk of hearing loss seemed to increase with earlier first year of noise exposure, but odds ratios were only statistically significant among baseline participants with first exposure before the 1980s (odds ratio: 1.90, 95% CI: 1.11; 3.22). We observed declining industrial noise levels, increased use of HPD and no significant impact on hearing thresholds from current ambient industrial noise levels, which indicated a successful implementation of Danish hearing conservation programs.

  16. Leakage of caesium braquitherapy sources

    International Nuclear Information System (INIS)

    Lozada, J.A.

    1998-01-01

    In several Venezuelan public hospitals where cervix uteri tumours are treated by intracavitary radiotherapy, that use manual after loading Fletcher method, with Caesium 137 sources, the use of improper source holders, locally manufactured from pieces of drainage plastic tubing, which deteriorated and created a corrosive environment all around the sources, omission of manufacturer's recommendations regarding corrosion information, source storage, inspection and testing, violation of International Atomic Energy Agency Radiation Protection Procedures, and lack of proper regulatory control, resulted integrity damage to about sixty special form sources (ISO2919 C 63322), leakage of Cs-137 from a supposed insoluble refractory active content (caesium silicoaluminate), and contamination of applicators, floors and bedding. When the situation was detected by means removal contamination tests, after routine inspections, the sources were removed from the hospitals, decontaminated by means of immersion in 3% EDTA solution in ultrasonic bath, subjected to leaking assessment tests, and the ones that passed were placed in low cost stainless steel source holders, designed and built by the instituto Venezolano de Investigaciones Cientificas (IVIC) returned to the hospitals. The leaking sources were removed from use and considered radioactive waste. In order to avoid the occurrence of similar situations, all the importers of such sources are now required to send them to IVIC for testing and placement in proper source holders, before they are shipped to the hospitals. (author)

  17. Climate Policy and Carbon Leakage

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    This report explores the effects of the EU emissions trading scheme on the aluminium sector (i.e. competitiveness loss and carbon leakage). With its very high electricity intensity, primary aluminium stands out in the heavy industry picture: a sector whose emissions are not capped in the present EU ETS, European aluminium smelters still stand to lose profit margins and, possibly, market shares, as electricity prices increase following CO2 caps on generators' emissions - the famous pass-through of CO2 prices into electricity prices. The analysis includes a method of quantification of this issue, based on two indicators: profit margins and trade flows. As the EU is at the forefront of such policy, the paper provides policy messages to all countries on how trade exposed energy-intensive industries can be 'moved' by carbon constraint. This also is a contentious topic in Australia, Japan, New Zealand, and the US, where ambitious climate policies -- including cap-and-trade systems -- are currently debated.

  18. Coexistence of mitochondrial 12S rRNA C1494T and CO1/tRNASer(UCN) G7444A mutations in two Han Chinese pedigrees with aminoglycoside-induced and non-syndromic hearing loss

    International Nuclear Information System (INIS)

    Yuan Huijun; Chen Jing; Liu Xin; Cheng Jing; Wang Xinjian; Yang Li; Yang Shuzhi; Cao Juyang; Kang Dongyang; Dai Pu; Zha, Suoqiang; Han Dongyi; Young Wieyen; Guan Minxin

    2007-01-01

    Mutations in mitochondrial DNA are one of the important causes of hearing loss. We report here the clinical, genetic, and molecular characterization of two Han Chinese pedigrees with maternally transmitted aminoglycoside-induced and nonsyndromic bilateral hearing loss. Clinical evaluation revealed the wide range of severity, age-at-onset, and audiometric configuration of hearing impairment in matrilineal relatives in these families. The penetrances of hearing loss in these pedigrees were 20% and 18%, when aminoglycoside-induced deafness was included. When the effect of aminoglycosides was excluded, the penetrances of hearing loss in these seven pedigrees were 10% and 15%. Sequence analysis of the complete mitochondrial genomes in these pedigrees showed the presence of the deafness-associated 12S rRNA C1494T and CO1/tRNA Ser(UCN) G7444A mutations. Their distinct sets of mtDNA polymorphism belonged to Eastern Asian haplogroup C4a1, while other previously identified six Chinese mitochondrial genomes harboring the C1494T mutation belong to haplogroups D5a2, D, R, and F1, respectively. This suggested that the C1494T or G7444A mutation occurred sporadically and multiplied through evolution of the mitochondrial DNA (mtDNA). The absence of functionally significant mutations in tRNA and rRNAs or secondary LHON mutations in their mtDNA suggest that these mtDNA haplogroup-specific variants may not play an important role in the phenotypic expression of the 12S rRNA C1494T and CO1/tRNA Ser(UCN) G7444A mutations in those Chinese families. However, aminoglycosides and other nuclear modifier genes play a modifying role in the phenotypic manifestation of the C1494T mutation in these Chinese families

  19. Early identification of noise induced hearing loss: a pilot study on the use of distortion product otoacoustic emissions as an adjunct to screening audiometry in the mining industry

    CSIR Research Space (South Africa)

    Edwards, A

    2010-06-01

    Full Text Available ) and DPOAE levels, and the ability of the DPOAE test to identify early NIHL in these employees were evaluated. Most S/N ratios were within the acceptable levels of greater than 10 dBSPL, hearing levels were within the range of hearing that provide valid DPOAE...

  20. A predictive model of the association between gene polymorphism and the risk of noise-induced hearing loss caused by gunfire noise

    Directory of Open Access Journals (Sweden)

    Ben-Chih Yuan

    2012-01-01

    Conclusion: In this study, we found that although loud noise could usually result in hearing damage, the clinical characteristics of hearing loss were irrelevant to gunfire noise. The gene polymorphisms provide predictors for us to evaluate the risk of NIHL prior to gunshot training.

  1. Hearing Preservation in Cochlear Implant Surgery

    Directory of Open Access Journals (Sweden)

    Priscila Carvalho Miranda

    2014-01-01

    Full Text Available In the past, it was thought that hearing loss patients with residual low-frequency hearing would not be good candidates for cochlear implantation since insertion was expected to induce inner ear trauma. Recent advances in electrode design and surgical techniques have made the preservation of residual low-frequency hearing achievable and desirable. The importance of preserving residual low-frequency hearing cannot be underestimated in light of the added benefit of hearing in noisy atmospheres and in music quality. The concept of electrical and acoustic stimulation involves electrically stimulating the nonfunctional, high-frequency region of the cochlea with a cochlear implant and applying a hearing aid in the low-frequency range. The principle of preserving low-frequency hearing by a “soft surgery” cochlear implantation could also be useful to the population of children who might profit from regenerative hair cell therapy in the future. Main aspects of low-frequency hearing preservation surgery are discussed in this review: its brief history, electrode design, principles and advantages of electric-acoustic stimulation, surgical technique, and further implications of this new treatment possibility for hearing impaired patients.

  2. A single dose of dexamethasone encapsulated in polyethylene glycol-coated polylactic acid nanoparticles attenuates cisplatin-induced hearing loss following round window membrane administration

    Directory of Open Access Journals (Sweden)

    Sun CL

    2015-05-01

    kHz frequencies when compared to the control of free DEX formulation. Histological analyses indicated that the administration of DEX-NPs did not induce local inflammatory responses. Therefore, prolonged delivery of DEX by PEG-PLA nanoparticles through local RWM diffusion (administration significantly protected the hair cells and auditory function in guinea pigs from cisplatin toxicity, as determined at both histological and functional levels, suggesting the potential therapeutic benefits in clinical applications.Keywords: stealth nanoparticles, dexamethasone, single-dose administration, cisplatin-induced hearing loss

  3. Sodium leakage experience at the prototype FBR Monju

    International Nuclear Information System (INIS)

    Miyakawa, A.; Maeda, H.; Kani, Y.; Ito, K.

    2000-01-01

    Monju is Japan's prototype fast breeder reactor: 280 MWe (714 MWt), fueled with mixed oxides of plutonium and uranium, cooled by liquid sodium. Construction was started in 1985 and initial criticality was attained in April 1994. On 8th December 1995, sodium leakage from a secondary circuit occurred in a piping room of the reactor auxiliary building. The secondary sodium leaked through a temperature sensor, due to the breakaway of the tip of the thermocouple well tube installed near the secondary circuit outlet of the intermediate heat exchanger (IHX). The reactor remained cooled and thus, from the viewpoint of radiological hazards, the safety of the reactor was secured. There was no release of radioactive material. There were no adverse effects for personnel and the surrounding environment. The thermocouple well tube failure resulted from high cycle fatigue due to flow induced vibration. It was found that this flow induced vibration was not caused by well-known Von Karman vortex shedding, but a symmetric vortex shedding. The design of the thermocouple well, which was subject to avoid this phenomenon, was reviewed. A new design guide against the flow-induced vibration was prepared by JNC (Japan Nuclear Cycle Development Institute). This is more comprehensive and definitive than the existing guide 'ASME N-1300' (Flow-induced vibration of tube and tube banks). New thermocouple well designs were proposed consistent with this design guide. To prevent a recurrence of the secondary sodium leakage incident, comprehensive design review activities were started for the purpose of checking the safety and reliability of the plant. As a result, several aspects to be improved were identified and improvements and countermeasures have been studied. The main improvements and countermeasures are as follows: To enable the operators to understand and react to incidents quickly, new sodium leakage detectors (TV monitors, smoke sensors) and a new surveillance system will be installed; To

  4. Music exposure and hearing disorders: an overview.

    Science.gov (United States)

    Zhao, Fei; Manchaiah, Vinaya K C; French, David; Price, Sharon M

    2010-01-01

    It has been generally accepted that excessive exposure to loud music causes various hearing symptoms (e.g. tinnitus) and consequently leads to a risk of permanent hearing damage, known as noise-induced hearing loss (NIHL). Such potential risk of NIHL due to loud music exposure has been widely investigated in musicians and people working in music venues. With advancements in sound technology and rapid developments in the music industry, increasing numbers of people, particularly adolescents and young adults, are exposing themselves to music on a voluntary basis at potentially harmful levels, and over a substantial period of time, which can also cause NIHL. However, because of insufficient audiometric evidence of hearing loss caused purely by music exposure, there is still disagreement and speculation about the risk of hearing loss from music exposure alone. Many studies have suggested using advanced audiological measurements as more sensitive and efficient tools to monitor hearing status as early indicators of cochlear dysfunction. The purpose of this review is to provide further insight into the potential risk of hearing loss caused by exposure to loud music, and thus contribute to further raising awareness of music induced hearing loss.

  5. Leakage Resilient Secure Two-Party Computation

    DEFF Research Database (Denmark)

    Damgård, Ivan Bjerre; Hazay, Carmit; Patra, Arpita

    2012-01-01

    we initiate the study of {\\em secure two-party computation in the presence of leakage}, where on top of corrupting one of the parties the adversary obtains leakage from the content of the secret memory of the honest party. Our study involves the following contributions: \\BE \\item {\\em Security...... and returns its result. Almost independently of secure computation, the area of {\\em leakage resilient cryptography} has recently been evolving intensively, studying the question of designing cryptographic primitives that remain secure even when some information about the secret key is leaked. In this paper...

  6. Method to detect steam generator tube leakage

    International Nuclear Information System (INIS)

    Watabe, Kiyomi

    1994-01-01

    It is important for plant operation to detect minor leakages from the steam generator tube at an early stage, thus, leakage detection has been performed using a condenser air ejector gas monitor and a steam generator blow down monitor, etc. In this study highly-sensitive main steam line monitors have been developed in order to identify leakages in the steam generator more quickly and accurately. The performance of the monitors was verified and the demonstration test at the actual plant was conducted for their intended application to the plants. (author)

  7. Analysis of audiometric notch as a noise-induced hearing loss phenotype in US youth: data from the National Health And Nutrition Examination Survey, 2005-2010.

    Science.gov (United States)

    Bhatt, Ishan S; Guthrie, O'neil

    2017-06-01

    Bilateral audiometric notch (BN) at 4000-6000 Hz was identified as a noise-induced hearing loss (NIHL) phenotype for genetic association analysis in college-aged musicians. This study analysed BN in a sample of US youth. Prevalence of the BN within the study sample was determined and logistic-regression analyses were performed to identify audiologic and other demographic factors associated with BN. Computer-simulated "flat" audiograms were used to estimate potential influence of false-positive rates in estimating the prevalence of the BN. 2348 participants (12-19 years) following the inclusion criteria were selected from the National Health and Nutrition Examination Survey data (2005-2010). The prevalence of BN was 16.6%. Almost 55.6% of the participants showed notch in at least one ear. Noise exposure, gender, ethnicity and age showed significant relationship with the BN. Computer simulation revealed that 5.5% of simulated participants with "flat" audiograms showed BN. Association of noise exposure with BN suggests that it is a useful NIHL phenotype for genetic association analyses. However, further research is necessary to reduce false-positive rates in notch identification.

  8. Can Baby Hear?

    Science.gov (United States)

    ... born in the United States are deaf or hard-of-hearing. Research shows that early intervention with hearing devices and educational services can help children with hearing loss to develop language skills at the same rate as their hearing peers. ...

  9. Hard of Hearing?

    DEFF Research Database (Denmark)

    T Christensen, Vibeke

    This summary presents the results of a study of the impact of reduced hearing in relation to labour-market attachment and working life. Reduced hearing contributes to early retirement. Many people with impaired hearing are not aware of the impact of their hearing problems on their working life an...

  10. Tracking the expression of excitatory and inhibitory neurotransmission-related proteins and neuroplasticity markers after noise induced hearing loss.

    Directory of Open Access Journals (Sweden)

    Cherylea J Browne

    Full Text Available Excessive exposure to loud noise can damage the cochlea and create a hearing loss. These pathologies coincide with a range of CNS changes including reorganisation of frequency representation, alterations in the pattern of spontaneous activity and changed expression of excitatory and inhibitory neurotransmitters. Moreover, damage to the cochlea is often accompanied by acoustic disorders such as hyperacusis and tinnitus, suggesting that one or more of these neuronal changes may be involved in these disorders, although the mechanisms remain unknown. We tested the hypothesis that excessive noise exposure increases expression of markers of excitation and plasticity, and decreases expression of inhibitory markers over a 32-day recovery period. Adult rats (n = 25 were monaurally exposed to a loud noise (16 kHz, 1/10(th octave band pass (115 dB SPL for 1-hour, or left as non-exposed controls (n = 5. Animals were euthanased at either 0, 4, 8, 16 or 32 days following acoustic trauma. We used Western Blots to quantify protein levels of GABA(A receptor subunit α1 (GABA(Aα1, Glutamic-Acid Decarboxylase-67 (GAD-67, N-Methyl-D-Aspartate receptor subunit 2A (NR2A, Calbindin (Calb1 and Growth Associated Protein 43 (GAP-43 in the Auditory Cortex (AC, Inferior Colliculus (IC and Dorsal Cochlear Nucleus (DCN. Compared to sham-exposed controls, noise-exposed animals had significantly (p<0.05: lower levels of GABA(Aα1 in the contralateral AC at day-16 and day-32, lower levels of GAD-67 in the ipsilateral DCN at day-4, lower levels of Calb1 in the ipsilateral DCN at day-0, lower levels of GABA(Aα1 in the ipsilateral AC at day-4 and day-32. GAP-43 was reduced in the ipsilateral AC for the duration of the experiment. These complex fluctuations in protein expression suggests that for at least a month following acoustic trauma the auditory system is adapting to a new pattern of sensory input.

  11. CERN hearing day

    CERN Multimedia

    2005-01-01

    1 in 10 people suffer from hearing loss - do you? The Medical Service invites everyone working on the CERN site to participate in the NATIONAL HEARING DAY on: Thursday 10th March 2005 From 9am to 4pm The Infirmary, Blg. 57, Ground Floor We will be offering hearing tests (audiograms), as well as information and advice on hearing loss, tinnitus, etc. Deafness does not just affect the elderly: in Europe, 50% of the hearing-impaired are under the age of 55. Exposure to excessive noise is one of the main reasons for hearing problems but PREVENTION IS POSSIBLE. For example, hearing protection devices can prevent 80% of tinnitus cases.

  12. CERN hearing day

    CERN Multimedia

    2005-01-01

    1 in 10 people suffer from hearing loss - do you? The Medical Service invites everyone working on CERN premises to participate in the National Hearing Day on: Thursday 10th March From 9am to 4pm The Infirmary, Blg. 57, Gr.Fl. We will be offering hearing tests (audiogram); information, advice on hearing loss, tinnitus and more. Deafness does not just affect the elderly: in Europe, 50% the hearing-impaired are under the age of 55. Exposure to excessive noise is one of the main reasons for hearing loss. But PREVENTION IS POSSIBLE AND EFFECTIVE: for example, Hearing protection devices could reduce tinnitus cases by 80%.

  13. CERN hearing day

    CERN Document Server

    2005-01-01

    1 in 10 people suffer from hearing loss - do you? The Medical Service invites everyone working on CERN premises to participate in the National Hearing Day on: Thursday 10th March From 9am to 4pm The Infirmary, Blg. 57, Gr.Fl. We will be offering hearing tests (audiogram); information, advice on hearing loss, tinnitus and more. Deafness does not just affect the elderly: in Europe, 50% the hearing-impaired are under the age of 55. Exposure to excessive noise is one of the main reasons for hearing loss. But prevention is possible and effective: for example, Hearing protection devices could reduce tinnitus cases by 80%.

  14. CERN hearing day

    CERN Multimedia

    2005-01-01

    1 in 10 people suffer from hearing loss ? do you? The Medical Service invites everyone working on the CERN site to participate in the NATIONAL HEARING DAY on: Thursday 10th March 2005 From 9am to 4pm The Infirmary, Blg. 57, Ground Floor We will be offering hearing tests (audiograms), as well as information and advice on hearing loss, tinnitus, etc. Deafness does not just affect the elderly: in Europe, 50% of the hearing-impaired are under the age of 55. Exposure to excessive noise is one of the main reasons for hearing problems but prevention is possible. For example, hearing protection devices can prevent 80% of tinnitus cases.

  15. Pre-enlistment hearing loss and hearing loss disability among US soldiers and marines

    Directory of Open Access Journals (Sweden)

    Marlene E Gubata

    2013-01-01

    Full Text Available Hearing loss is a common condition among US adults, with some evidence of increasing prevalence in young adults. Noise-induced hearing loss attributable to employment is a significant source of preventable morbidity world-wide. The US military population is largely comprised of young adult males serving in a wide variety of occupations, many in high noise-level conditions, at least episodically. To identify accession and service-related risk factors for hearing-related disability, matched case-control study of US military personnel was conducted. Individuals evaluated for hearing loss disability in the US Army and Marine Corps were frequency matched to controls without history of disability evaluation on service and enlistment year. Conditional logistic regression was used to examine the association between accession and service-related factors and hearing-related disability evaluations between October 2002 and September 2010. Individuals with medically disqualifying audiograms or hearing loss diagnoses at application for military service were 8 and 4 times more likely, respectively, to have a disability evaluation related to hearing loss, after controlling for relevant accession, demographic, and service-related factors. Conservative hearing loss thresholds on pre-enlistment audiograms, stricter hearing loss medical waiver policies or qualified baseline audiograms pre-enlistment are needed in the U.S military. Industrial corporations or labor unions may also benefit from identifying individuals with moderate hearing loss at the time of employment to ensure use of personal protective equipment and engineer controls of noise.

  16. The Master Hearing Aid

    Science.gov (United States)

    Curran, James R.

    2013-01-01

    As early as the 1930s the term Master Hearing Aid (MHA) described a device used in the fitting of hearing aids. In their original form, the MHA was a desktop system that allowed for simulated or actual adjustment of hearing aid components that resulted in a changed hearing aid response. Over the years the MHA saw many embodiments and contributed to a number of rationales for the fitting of hearing aids. During these same years, the MHA was viewed by many as an inappropriate means of demonstrating hearing aids; the audio quality of the desktop systems was often superior to the hearing aids themselves. These opinions and the evolution of the MHA have molded the modern perception of hearing aids and the techniques used in the fitting of hearing aids. This article reports on a history of the MHA and its influence on the fitting of hearing aids. PMID:23686682

  17. AKTIS Nr. 12: To better understand radioactive aerosol deposit in order to better measure it; Radio-induced lesions: a new step towards healing; Modelling the collapse of an immersed grain column; To better model soot deposit; Towards the prediction of the leakage rate of containment enclosures

    International Nuclear Information System (INIS)

    Benderitter, Marc; Perales, Frederic; Monerie, Yann; Maro, Denis; Boyer, Patrick; Lemaitre, Pascal; Porcheron, Emmanuel; Depuydt, Guillaume; Masson, Olivier; Gensdarmes, Francois

    2013-04-01

    This publication presents the main results of researches undertaken by the IRSN in the field of radiation protection, nuclear safety and security. The topics herein addressed are: radio-induced lesions as a new step towards healing (case of injection mesenchymal stem cells for the treatment of induced severe colorectal lesions), the modelling of the collapse of an immersed grain column (to study the nuclear fuel behaviour in an accidental situation through a modelling of fluid-grain interactions), a better understanding of radioactive aerosol deposit (to study particle or aerosol deposits after radioactive releases in the atmosphere in case of accident), a better modelling of soot deposits (in case of fire), the prediction of leakage rates of containment enclosures (ageing phenomena of installations, systems and equipment, with the case of cracks due to material ageing and resulting in confinement losses which could thus be quantified)

  18. Effect of GRM7 polymorphisms on the development of noise-induced hearing loss in Chinese Han workers: a nested case-control study.

    Science.gov (United States)

    Yu, Peipei; Jiao, Jie; Chen, Guoshun; Zhou, Wenhui; Zhang, Huanling; Wu, Hui; Li, Yanhong; Gu, Guizhen; Zheng, Yuxin; Yu, Yue; Yu, Shanfa

    2018-01-05

    Noise-induced hearing loss (NIHL) is a complex, irreversible disease caused by the interaction of genetic and environmental factors. In recent years, a great many studies have been done to explore the NIHL susceptibility genes among humans. So far, high powerful detections have been founded that genes of potassium ion channel genes (KCNQ4 and KCNE1), catalase (CAT), protocadherin 15 (PCDH15), myosin 14 (MYH14) and heart shock protein (HSP70) which have been identified in more than one population may be associated with the susceptibility to NIHL. As for metabolic glutamate receptor7 gene (GRM7), a lot of researches mainly focus on age-related hearing loss (ARHL) and the results have shown that the polymorphisms of GRM7 are linked to the development of ARHL. However, little is known about the association of GRM7 and the susceptibility to NIHL. Therefore, the aim of this study was to explore the effect of GRM7 polymorphisms on the susceptibility to NIHL. A nested case-control study based on the cohort in a Chinese steel factory was implemented in 292 cases and 584 controls matched with the same sex, the age difference ≤ 5 years old, the same type of work, duration of occupational noise exposure ≤2 years. Five single nucleotide polymorphisms (SNPs) of GRM7 were gained through selecting and genotyping SNPs. Conditional logistic regression analysis was used to assess the main effect of GRM7 polymorphisms on the susceptibility to NIHL and the gene-by-environment interaction. Furthermore, the gene-by-gene interactions were analyzed by generalized multiple dimensionality reduction (GMDR). This research discovered for the first time that the mutant allele C in rs1485175 of the GMR7 may decrease individuals' susceptibility to NIHL. The interaction between rs1485175 and cumulative noise exposure (CNE) at high level was found after the stratification according to CNE (p/p bon  = 0.014/0.007, OR = 0.550, 95% CI: 0.340-0.891). Permutation test of GMDR suggested

  19. Signal attenuation due to cavity leakage

    International Nuclear Information System (INIS)

    Sherman, M.H.; Modera, M.P.

    1988-01-01

    The propagation of sound waves in fluids requires information about three properties of the system: capacitance (compressibility), resistance (friction), and inductance (inertia). Acoustical design techniques to date have tended to ignore the frictional effects associated with airflow across the envelope of the acoustic cavity (e.g., resistive vents). Since such leakage through the cavity envelope is best expressed with a power law dependence on the pressure, standard Fourier techniques that rely on linearity cannot be used. In this article, the theory relevant to nonlinear leakage is developed and equations presented. Potential applications of the theory to techniques for quantifying the leakage of buildings are presented. Experimental results from pressure decays in a full-scale test structure are presented and the leakage so measured is compared with independent measurements to demonstrate the technique

  20. Apparatus for detecting leakage of liquid sodium

    Science.gov (United States)

    Himeno, Yoshiaki

    1978-01-01

    An apparatus for detecting the leakage of liquid sodium includes a cable-like sensor adapted to be secured to a wall of piping or other equipment having sodium on the opposite side of the wall, and the sensor includes a core wire electrically connected to the wall through a leak current detector and a power source. An accidental leakage of the liquid sodium causes the corrosion of a metallic layer and an insulative layer of the sensor by products resulted from a reaction of sodium with water or oxygen in the atmospheric air so as to decrease the resistance between the core wire and the wall. Thus, the leakage is detected as an increase in the leaking electrical current. The apparatus is especially adapted for use in detecting the leakage of liquid sodium from sodium-conveying pipes or equipment in a fast breeder reactor.

  1. Electroplating eliminates gas leakage in brazed areas

    Science.gov (United States)

    Leigh, J. D.

    1966-01-01

    Electroplating method seals brazed or welded joints against gas leakage under high pressure. Any conventional electroplating process with many different metal anodes can be used, as well as the build up of layers of different metals to any required thickness.

  2. Is there a risk to safety when working in the New South Wales underground coal-mining industry while having binaural noise-induced hearing loss?

    Energy Technology Data Exchange (ETDEWEB)

    Viljoen, D.A.; Nie, V.; Guest, M. [University of Newcastle, Newcastle, NSW (Australia)

    2006-03-15

    This study is designed to investigate the possible association between hearing loss and accidents in the New South Wales underground coal-mining industry. The study was conducted, gathering data over a 10-year period from 1994 to 2003, which identified 97 cases that have had accidents and 983 controls that have had no accidents. Hearing loss levels were noted and compared in the cases and controls. Multiple logistic regression was used to determine whether the variables were significant risk factors in the occurrence of accidents. Hearing loss levels in the total cohort varied from 0 to 54%. The proportion of cases with hearing loss appeared to be significantly higher in the young age group of {lt} 29 years than in the controls, but was not significantly different in the older age groups. This study indicates that workers who have lost up to 54% binaural high tone hearing and are older than 29 years do not appear to have an increased risk to safety when compared with workers who do not have hearing loss. However, workers in the young age group of {lt} 29 years who have high tone hearing loss may be at an increased risk of accident.

  3. Analysis of ONKALO water leakage mapping results

    International Nuclear Information System (INIS)

    Ahokas, H.; Nummela, J; Turku, J.

    2014-04-01

    As part of the programme for the final disposal of spent nuclear fuel, an analysis has been compiled of water leakage mapping performed in ONKALO. Leakage mapping is part of the Olkiluoto Monitoring Programme (OMO) and the field work has been carried out by Posiva Oy. The main objective of the study is to analyse differences detected between mapping campaigns carried out typically twice a year in 2005-2012. Differences were estimated to be caused by the differences in groundwater conditions caused by seasonal effects or by differences between the years. The effect of technical changes like shotcreting, postgrouting, ventilation etc. on the results was also studied. The development of the visualisation of mapping results was also an objective of this work. Leakage mapping results have been reported yearly in the monitoring reports of Hydrology with some brief comments on the detected differences. In this study, the development of the total area and the number of different leakages as well as the correlation of changes with shotcreting and grouting operations were studied. In addition, traces of fractures on tunnel surfaces, and the location of rock bolts and drain pipes were illustrated together with leakage mapping. In water leakage mapping, the tunnel surfaces are visually mapped to five categories: dry, damp, wet, dripping and flowing. Major changes were detected in the total area of damp leakages. It is likely that the increase has been caused by the condensation of warm ventilation air on the tunnel surfaces and the corresponding decrease by the evaporation of moisture into the dry ventilation air. Shotcreting deep in ONKALO may also have decreased the total area of damp leakages. Changes in the total area and number of wet leakages correlate at least near the surface with differences in yearly precipitation. It is possible that strong rains have also caused a temporary increase in wet leakages. Dripping and wet leakages have been observed on average more

  4. Analysis of ONKALO water leakage mapping results

    Energy Technology Data Exchange (ETDEWEB)

    Ahokas, H.; Nummela, J; Turku, J. [Poeyry Finland Oy, Vantaa (Finland)

    2014-04-15

    As part of the programme for the final disposal of spent nuclear fuel, an analysis has been compiled of water leakage mapping performed in ONKALO. Leakage mapping is part of the Olkiluoto Monitoring Programme (OMO) and the field work has been carried out by Posiva Oy. The main objective of the study is to analyse differences detected between mapping campaigns carried out typically twice a year in 2005-2012. Differences were estimated to be caused by the differences in groundwater conditions caused by seasonal effects or by differences between the years. The effect of technical changes like shotcreting, postgrouting, ventilation etc. on the results was also studied. The development of the visualisation of mapping results was also an objective of this work. Leakage mapping results have been reported yearly in the monitoring reports of Hydrology with some brief comments on the detected differences. In this study, the development of the total area and the number of different leakages as well as the correlation of changes with shotcreting and grouting operations were studied. In addition, traces of fractures on tunnel surfaces, and the location of rock bolts and drain pipes were illustrated together with leakage mapping. In water leakage mapping, the tunnel surfaces are visually mapped to five categories: dry, damp, wet, dripping and flowing. Major changes were detected in the total area of damp leakages. It is likely that the increase has been caused by the condensation of warm ventilation air on the tunnel surfaces and the corresponding decrease by the evaporation of moisture into the dry ventilation air. Shotcreting deep in ONKALO may also have decreased the total area of damp leakages. Changes in the total area and number of wet leakages correlate at least near the surface with differences in yearly precipitation. It is possible that strong rains have also caused a temporary increase in wet leakages. Dripping and wet leakages have been observed on average more

  5. Technology evaluation for space station atmospheric leakage

    Energy Technology Data Exchange (ETDEWEB)

    Lemon, D.K.; Friesel, M.A.; Griffin, J.W.; Skorpik, J.R.; Shepard, C.L.; Antoniak, Z.I.; Kurtz, R.J.

    1990-02-01

    A concern in operation of a space station is leakage of atmosphere through seal points and through the walls as a result of damage from particle (space debris and micrometeoroid) impacts. This report describes a concept for a monitoring system to detect atmosphere leakage and locate the leak point. The concept is based on analysis and testing of two basic methods selected from an initial technology survey of potential approaches. 18 refs., 58 figs., 5 tabs.

  6. Associação entre perda auditiva induzida pelo ruído e zumbidos Association between noise-induced hearing loss and tinnitus

    Directory of Open Access Journals (Sweden)

    Adriano Dias

    2006-01-01

    Full Text Available O estudo verificou a associação entre perda auditiva induzida por ruído (PAIR e queixa de zumbido em trabalhadores expostos ao ruído ocupacional. Foram entrevistados e avaliados trabalhadores com histórico de exposição ao ruído ocupacional atendidos em dois ambulatórios de audiologia. Estudou-se a existência de associação entre PAIR e ocorrência de zumbido por intermédio do ajuste de modelo de regressão logística, tendo como variável dependente o zumbido e como variável independente a PAIR, classificada em seis graus, controlada pelas co-variáveis idade e tempo de exposição ao ruído. Os dados foram coletados entre abril e outubro de 2003, na Cidade de Bauru, Estado de São Paulo, Brasil, contemplando 284 trabalhadores. Estimou-se que a prevalência de zumbido aumenta de acordo com a evolução do dano auditivo, controlado para a idade e tempo de exposição ao ruído. Os achados justificam o investimento em programas de conservação auditiva particularmente voltados para o controle da emissão de ruídos na fonte e para a intervenção na evolução das perdas auditivas geradas pela exposição ao ruído visando à manutenção da saúde auditiva e à diminuição dos sintomas associados.The objective of this study was to verify an association between noise-induced hearing loss (NIHL and tinnitus in workers exposed to occupational noise. Workers with a history of work noise exposure who attended two audiology outpatient clinics were interviewed and evaluated. The statistical association between NIHL and tinnitus was evaluated using an adjusted linear regression model, with tinnitus as the dependent variable and NIHL, classified into six levels, as the independent variable, with age and length of noise exposure as covariates. Data were collected from 284 workers between April and October, 2003, in Bauru, São Paulo State, Brazil. Tinnitus was observed to increase with the progression of auditory damage, controlled by age

  7. Carbon leakage from a Nordic perspective

    Energy Technology Data Exchange (ETDEWEB)

    Naess-Schmidt, S.; Hansen, Martin Bo; Sand Kirk, J. [Copenhagen Economics, Copenhagen (Denmark)

    2012-02-15

    Carbon pricing is generally considered a highly effective tool in reducing carbon emissions. Putting a price on carbon provides incentives for users and producers of fossil fuels to reduce consumption and develop low carbon products and processes. However, pursuing an ambitious climate policy can lead to carbon leakage, which refers to a situation where unilateral or regional climate change policy drives the relocation of industry investments and installations, and associated emissions, to third countries. This report by Copenhagen Economics has been commissioned by the Nordic Council of Ministers to give an overview of the industries at risk of carbon leakage in the Nordic countries, and estimate the expected extent of carbon leakage from unilateral climate policies in the Nordic countries. The report also assesses available policy options that may reduce the risk of carbon leakage, such as exemptions from energy tax and exemptions from quota obligations under green certificate schemes. The key drivers of carbon leakage are identified, which include energy intensity, product differentiation, transportation costs and capital intensity. The analysis suggests that industries such as paper and pulp, iron and steel, aluminium, cement, pharmaceuticals, chemicals, and fertilizers are most at risk of carbon leakage in the Nordic manufacturing sector. (Author)

  8. Hydrogeochemical Impact of CO2 Leakage from Geological Sequestration on Shallow Potable Aquifers

    DEFF Research Database (Denmark)

    Cahill, Aaron Graham

    . Although considered highly unlikely following appropriate site selection, leakage of CO2 from CCGS forms a major concern for both scientists and the public. Leakage would potentially occur through faults or abandoned boreholes and ultimately result in upward migration and discharge to the atmosphere....... During migration CO2 would dissolve into groundwater forming carbonic acid, induce water-rock reactions and thus change groundwater chemistry. Therefore prior to implementation of this potentially necessary technology, environmental risks associated with leakage must be understood. Over the past 10 years...... it be detected geochemically? Some common hydrochemical development is apparent from the literature however many aspects of hydrogeological and hydrogeochemical impact of leakage into shallow aquifers used in water supply remain unclear. In this Ph.D. study an integrated approach was employed in order to answer...

  9. Noise-Induced Hearing Loss – A Preventable Disease? Results of a 10-Year Longitudinal Study of Workers Exposed to Occupational Noise

    Science.gov (United States)

    Frederiksen, Thomas W.; Ramlau-Hansen, Cecilia H.; Stokholm, Zara A.; Grynderup, Matias B.; Hansen, Åse M.; Kristiansen, Jesper; Vestergaard, Jesper M.; Bonde, Jens P.; Kolstad, Henrik A.

    2017-01-01

    Aims: To survey current, Danish industrial noise levels and the use of hearing protection devices (HPD) over a 10-year period and to characterise the association between occupational noise and hearing threshold shift in the same period. Furthermore, the risk of hearing loss among the baseline and the follow-up populations according to first year of occupational noise exposure is evaluated. Materials and Methods: In 2001–2003, we conducted a baseline survey of noise- and hearing-related disorders in 11 industries with suspected high noise levels. In 2009–2010, we were able to follow up on 271 out of the 554 baseline workers (49%). Mean noise levels per industry and self-reported HPD use are described at baseline and follow-up. The association between cumulative occupational noise exposure and hearing threshold shift over the 10-year period was assessed using linear regression, and the risk of hearing loss according to year of first occupational noise exposure was evaluated with logistic regression. Results: Over the 10-year period, mean noise levels declined from 83.9 dB(A) to 82.8 dB(A), and for workers exposed >85 dB(A), the use of HPD increased from 70.1 to 76.1%. We found a weak, statistically insignificant, inverse association between higher ambient cumulative noise exposure and poorer hearing (−0.10 dB hearing threshold shift per dB-year (95% confidence interval (CI): −0.36; 0.16)). The risk of hearing loss seemed to increase with earlier first year of noise exposure, but odds ratios were only statistically significant among baseline participants with first exposure before the 1980s (odds ratio: 1.90, 95% CI: 1.11; 3.22). Conclusions: We observed declining industrial noise levels, increased use of HPD and no significant impact on hearing thresholds from current ambient industrial noise levels, which indicated a successful implementation of Danish hearing conservation programs. PMID:29192620

  10. Noise-Induced Hearing Loss – A Preventable Disease? Results of a 10-Year Longitudinal Study of Workers Exposed to Occupational Noise

    Directory of Open Access Journals (Sweden)

    Thomas W Frederiksen

    2017-01-01

    Full Text Available Aims: To survey current, Danish industrial noise levels and the use of hearing protection devices (HPD over a 10-year period and to characterise the association between occupational noise and hearing threshold shift in the same period. Furthermore, the risk of hearing loss among the baseline and the follow-up populations according to first year of occupational noise exposure is evaluated. Materials and Methods: In 2001–2003, we conducted a baseline survey of noise- and hearing-related disorders in 11 industries with suspected high noise levels. In 2009–2010, we were able to follow up on 271 out of the 554 baseline workers (49%. Mean noise levels per industry and self-reported HPD use are described at baseline and follow-up. The association between cumulative occupational noise exposure and hearing threshold shift over the 10-year period was assessed using linear regression, and the risk of hearing loss according to year of first occupational noise exposure was evaluated with logistic regression. Results: Over the 10-year period, mean noise levels declined from 83.9 dB(A to 82.8 dB(A, and for workers exposed >85 dB(A, the use of HPD increased from 70.1 to 76.1%. We found a weak, statistically insignificant, inverse association between higher ambient cumulative noise exposure and poorer hearing (−0.10 dB hearing threshold shift per dB-year (95% confidence interval (CI: −0.36; 0.16. The risk of hearing loss seemed to increase with earlier first year of noise exposure, but odds ratios were only statistically significant among baseline participants with first exposure before the 1980s (odds ratio: 1.90, 95% CI: 1.11; 3.22. Conclusions: We observed declining industrial noise levels, increased use of HPD and no significant impact on hearing thresholds from current ambient industrial noise levels, which indicated a successful implementation of Danish hearing conservation programs.

  11. Pickering unit 1 containment leakage characterization

    International Nuclear Information System (INIS)

    Zakaib, G.D.

    1994-01-01

    Results of the design pressure test carried out on Pickering Reactor Building number 1 during late 1992 showed that the leakage rate of the building was close to the safety analysis value of 2.7% contained mass per hour at the design pressure of 41.4 kPa(g) and was significantly higher than that reported after the previous test conducted in the spring of 1987. This unexpected finding initiated the longest and the most comprehensive containment leakage investigation ever undertaken by Ontario Hydro. A thorough investigation of leakage behaviour by repeated testing, inspections, leak search and analysis was launched. The extensive leak search effort included items such as: leak source detection by soap solution application, use of ultrasonic detectors, fogging and tracer gas techniques, systematic systems isolation, thermal imaging of the exterior, and quantification of leak sites by flowmeter and bagging. Using a specially designed volumetric technique, the root cause of the problem was finally confirmed as being due to 'pressure dependent laminar leakage' through the hairline cracks in the dome concrete. Structural analysis indicated that the thermal gradients and pressure loading combined to cause the cracking early in the structure's operating history and that overall structural integrity has not been compromised. Leakage rate analysis using a new fluid mechanics model augmented by the effect of thermal strains indicated that the leakage could be significantly less under certain transient temperature gradient conditions. Several options for repairing the dome were considered by a multidisciplinary team and it was finally decided to apply a specially engineered multilayer elastomeric coating to the exterior concrete surface. When the unit was re-tested in October 1993, a dramatic ten-fold improvement in leakage rate (down to 0.25%/h at design pressure) was observed. This is lower than even the commissioning results and comparable to the performance of newer units

  12. Structurally diverse natural products that cause potassium leakage trigger multicellularity in Bacillus subtilis.

    Science.gov (United States)

    López, Daniel; Fischbach, Michael A; Chu, Frances; Losick, Richard; Kolter, Roberto

    2009-01-06

    We report a previously undescribed quorum-sensing mechanism for triggering multicellularity in Bacillus subtilis. B. subtilis forms communities of cells known as biofilms in response to an unknown signal. We discovered that biofilm formation is stimulated by a variety of small molecules produced by bacteria--including the B. subtilis nonribosomal peptide surfactin--that share the ability to induce potassium leakage. Natural products that do not cause potassium leakage failed to induce multicellularity. Small-molecule-induced multicellularity was prevented by the addition of potassium, but not sodium or lithium. Evidence is presented that potassium leakage stimulates the activity of a membrane protein kinase, KinC, which governs the expression of genes involved in biofilm formation. We propose that KinC responds to lowered intracellular potassium concentration and that this is a quorum-sensing mechanism that enables B. subtilis to respond to related and unrelated bacteria.

  13. Negotiating hearing disability and hearing disabled identities

    DEFF Research Database (Denmark)

    Lykke Hindhede, Anette

    2012-01-01

        Using disability theory as a framework and social science theories of identity to strengthen the arguments, this paper explores empirically how working-age adults confront the medical diagnosis of hearing impairment. For most participants hearing impairment threatens the stability of social...... interaction and the construction of hearing disabled identities is seen as shaped in the interaction with the hearing impaired person‟s surroundings. In order to overcome the potential stigmatisation the „passing‟ as normal becomes predominant. For many the diagnosis provokes radical redefinitions of the self....... The discursively produced categorisation and subjectivity of senescence mean that rehabilitation technologies such as hearing aids identify a particular life-style (disabled) which determines their social significance. Thus wearing a hearing aid works against the contemporary attempt to create socially ideal...

  14. How to attribute market leakage to CDM projects

    NARCIS (Netherlands)

    Vöhringer, F.; Kuosmanen, T.K.; Dellink, R.B.

    2006-01-01

    Economic studies suggest that market leakage rates of greenhouse gas abatement can reach the two-digit percentage range. Although the Marrakesh Accords require Clean Development Mechanism (CDM) projects to account for leakage, most projects neglect market leakage. Insufficient leakage accounting is

  15. Calculation of Leakage Inductance for High Frequency Transformers

    DEFF Research Database (Denmark)

    Ouyang, Ziwei; Jun, Zhang; Hurley, William Gerard

    2015-01-01

    Frequency dependent leakage inductance is often observed. High frequency eddy current effects cause a reduction in leakage inductance. The proximity effect between adjacent layers is responsible for the reduction of leakage inductance. This paper gives a detailed analysis of high frequency leakag...

  16. Hearing Aid and children

    Directory of Open Access Journals (Sweden)

    Jamileh Fatahi

    2002-07-01

    Full Text Available In order to develop oral communication, hearing impaired infants and young children must be able to hear speech comfortably and consistently. To day children with all degrees of hearing loss may be condidates for some kinds of amlification. As children differ from adults, many Factors should be consider in hearing aid selection, evaluation and fitting. For example the child age when he or she is candidate for custom instruments? Do we consider programmable Hearing aid? Are multi memory instruments appropriate for them? What about directional microphones? What style of hearing aid do we select? In this paper such questions are Answered.

  17. Congenital hearing impairment

    Energy Technology Data Exchange (ETDEWEB)

    Robson, Caroline D. [Children' s Hospital and Harvard Medical School, Division of Neuroradiology, Department of Radiology, Boston, MA (United States)

    2006-04-15

    Establishing the etiology of congenital hearing impairment can significantly improve treatment for certain causes of hearing loss and facilitates genetic counseling. High-resolution CT and MRI have contributed to the evaluation and management of hearing impairment. In addition, with the identification of innumerable genetic loci and genetic defects involved in hearing loss, genetic testing has emerged as an invaluable tool in the assessment of hearing impairment. Some of the common forms of congenital hearing loss are reviewed and their imaging features illustrated. (orig.)

  18. Congenital hearing impairment

    International Nuclear Information System (INIS)

    Robson, Caroline D.

    2006-01-01

    Establishing the etiology of congenital hearing impairment can significantly improve treatment for certain causes of hearing loss and facilitates genetic counseling. High-resolution CT and MRI have contributed to the evaluation and management of hearing impairment. In addition, with the identification of innumerable genetic loci and genetic defects involved in hearing loss, genetic testing has emerged as an invaluable tool in the assessment of hearing impairment. Some of the common forms of congenital hearing loss are reviewed and their imaging features illustrated. (orig.)

  19. Trends in incidence of occupational asthma, contact dermatitis, noise-induced hearing loss, carpal tunnel syndrome and upper limb musculoskeletal disorders in European countries from 2000 to 2012.

    Science.gov (United States)

    Stocks, S Jill; McNamee, Roseanne; van der Molen, Henk F; Paris, Christophe; Urban, Pavel; Campo, Giuseppe; Sauni, Riitta; Martínez Jarreta, Begoña; Valenty, Madeleine; Godderis, Lode; Miedinger, David; Jacquetin, Pascal; Gravseth, Hans M; Bonneterre, Vincent; Telle-Lamberton, Maylis; Bensefa-Colas, Lynda; Faye, Serge; Mylle, Godewina; Wannag, Axel; Samant, Yogindra; Pal, Teake; Scholz-Odermatt, Stefan; Papale, Adriano; Schouteden, Martijn; Colosio, Claudio; Mattioli, Stefano; Agius, Raymond

    2015-04-01

    The European Union (EU) strategy for health and safety at work underlines the need to reduce the incidence of occupational diseases (OD), but European statistics to evaluate this common goal are scarce. We aim to estimate and compare changes in incidence over time for occupational asthma, contact dermatitis, noise-induced hearing loss (NIHL), carpal tunnel syndrome (CTS) and upper limb musculoskeletal disorders across 10 European countries. OD surveillance systems that potentially reflected nationally representative trends in incidence within Belgium, the Czech Republic, Finland, France, Italy, the Netherlands, Norway, Spain, Switzerland and the UK provided data. Case counts were analysed using a negative binomial regression model with year as the main covariate. Many systems collected data from networks of 'centres', requiring the use of a multilevel negative binomial model. Some models made allowance for changes in compensation or reporting rules. Reports of contact dermatitis and asthma, conditions with shorter time between exposure to causal substances and OD, were consistently declining with only a few exceptions. For OD with physical causal exposures there was more variation between countries. Reported NIHL was increasing in Belgium, Spain, Switzerland and the Netherlands and decreasing elsewhere. Trends in CTS and upper limb musculoskeletal disorders varied widely within and between countries. This is the first direct comparison of trends in OD within Europe and is consistent with a positive impact of European initiatives addressing exposures relevant to asthma and contact dermatitis. Taking a more flexible approach allowed comparisons of surveillance data between and within countries without harmonisation of data collection methods. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  20. Predicting hearing thresholds and occupational hearing loss with multiple-frequency auditory steady-state responses.

    Science.gov (United States)

    Hsu, Ruey-Fen; Ho, Chi-Kung; Lu, Sheng-Nan; Chen, Shun-Sheng

    2010-10-01

    An objective investigation is needed to verify the existence and severity of hearing impairments resulting from work-related, noise-induced hearing loss in arbitration of medicolegal aspects. We investigated the accuracy of multiple-frequency auditory steady-state responses (Mf-ASSRs) between subjects with sensorineural hearing loss (SNHL) with and without occupational noise exposure. Cross-sectional study. Tertiary referral medical centre. Pure-tone audiometry and Mf-ASSRs were recorded in 88 subjects (34 patients had occupational noise-induced hearing loss [NIHL], 36 patients had SNHL without noise exposure, and 18 volunteers were normal controls). Inter- and intragroup comparisons were made. A predicting equation was derived using multiple linear regression analysis. ASSRs and pure-tone thresholds (PTTs) showed a strong correlation for all subjects (r = .77 ≈ .94). The relationship is demonstrated by the equationThe differences between the ASSR and PTT were significantly higher for the NIHL group than for the subjects with non-noise-induced SNHL (p tool for objectively evaluating hearing thresholds. Predictive value may be lower in subjects with occupational hearing loss. Regardless of carrier frequencies, the severity of hearing loss affects the steady-state response. Moreover, the ASSR may assist in detecting noise-induced injury of the auditory pathway. A multiple linear regression equation to accurately predict thresholds was shown that takes into consideration all effect factors.

  1. Determination of leakage areas in nuclear piping

    International Nuclear Information System (INIS)

    Keim, E.

    1997-01-01

    For the design and operation of nuclear power plants the Leak-Before-Break (LBB) behavior of a piping component has to be shown. This means that the length of a crack resulting in a leak is smaller than the critical crack length and that the leak is safely detectable by a suitable monitoring system. The LBB-concept of Siemens/KWU is based on computer codes for the evaluation of critical crack lengths, crack openings, leakage areas and leakage rates, developed by Siemens/KWU. In the experience with the leak rate program is described while this paper deals with the computation of crack openings and leakage areas of longitudinal and circumferential cracks by means of fracture mechanics. The leakage areas are determined by the integration of the crack openings along the crack front, considering plasticity and geometrical effects. They are evaluated with respect to minimum values for the design of leak detection systems, and maximum values for controlling jet and reaction forces. By means of fracture mechanics LBB for subcritical cracks has to be shown and the calculation of leakage areas is the basis for quantitatively determining the discharge rate of leaking subcritical through-wall cracks. The analytical approach and its validation will be presented for two examples of complex structures. The first one is a pipe branch containing a circumferential crack and the second one is a pipe bend with a longitudinal crack

  2. Sustainable management of leakage from wastewater pipelines.

    Science.gov (United States)

    DeSilva, D; Burn, S; Tjandraatmadja, G; Moglia, M; Davis, P; Wolf, L; Held, I; Vollertsen, J; Williams, W; Hafskjold, L

    2005-01-01

    Wastewater pipeline leakage is an emerging concern in Europe, especially with regards to the potential effect of leaking effluent on groundwater contamination and the effects infiltration has on the management of sewer reticulation systems. This paper describes efforts by Australia, in association with several European partners, towards the development of decision support tools to prioritize proactive rehabilitation of wastewater pipe networks to account for leakage. In the fundamental models for the decision support system, leakage is viewed as a function of pipeline system deterioration. The models rely on soil type identification across the service area to determine the aggressiveness of the pipe environment and for division of the area into zones based on pipe properties and operational conditions. By understanding the interaction between pipe materials, operating conditions, and the pipe environment in the mechanisms leading to pipe deterioration, the models allow the prediction of leakage rates in different zones across a network. The decision support system utilizes these models to predict the condition of pipes in individual zones, and to optimize the utilization of rehabilitation resources by targeting the areas with the highest leakage rates.

  3. Determination of leakage areas in nuclear piping

    Energy Technology Data Exchange (ETDEWEB)

    Keim, E. [Siemens/KWU, Erlangen (Germany)

    1997-04-01

    For the design and operation of nuclear power plants the Leak-Before-Break (LBB) behavior of a piping component has to be shown. This means that the length of a crack resulting in a leak is smaller than the critical crack length and that the leak is safely detectable by a suitable monitoring system. The LBB-concept of Siemens/KWU is based on computer codes for the evaluation of critical crack lengths, crack openings, leakage areas and leakage rates, developed by Siemens/KWU. In the experience with the leak rate program is described while this paper deals with the computation of crack openings and leakage areas of longitudinal and circumferential cracks by means of fracture mechanics. The leakage areas are determined by the integration of the crack openings along the crack front, considering plasticity and geometrical effects. They are evaluated with respect to minimum values for the design of leak detection systems, and maximum values for controlling jet and reaction forces. By means of fracture mechanics LBB for subcritical cracks has to be shown and the calculation of leakage areas is the basis for quantitatively determining the discharge rate of leaking subcritical through-wall cracks. The analytical approach and its validation will be presented for two examples of complex structures. The first one is a pipe branch containing a circumferential crack and the second one is a pipe bend with a longitudinal crack.

  4. Component external leakage and rupture frequency estimates

    International Nuclear Information System (INIS)

    Eide, S.A.; Khericha, S.T.; Calley, M.B.; Johnson, D.A.; Marteeny, M.L.

    1991-11-01

    In order to perform detailed internal flooding risk analyses of nuclear power plants, external leakage and rupture frequencies are needed for various types of components - piping, valves, pumps, flanges, and others. However, there appears to be no up-to-date, comprehensive source for such frequency estimates. This report attempts to fill that void. Based on a comprehensive search of Licensee Event Reports (LERs) contained in Nuclear Power Experience (NPE), and estimates of component populations and exposure times, component external leakage and rupture frequencies were generated. The remainder of this report covers the specifies of the NPE search for external leakage and rupture events, analysis of the data, a comparison with frequency estimates from other sources, and a discussion of the results

  5. Leakage-Resilient Circuits without Computational Assumptions

    DEFF Research Database (Denmark)

    Dziembowski, Stefan; Faust, Sebastian

    2012-01-01

    Physical cryptographic devices inadvertently leak information through numerous side-channels. Such leakage is exploited by so-called side-channel attacks, which often allow for a complete security breache. A recent trend in cryptography is to propose formal models to incorporate leakage...... on computational assumptions, our results are purely information-theoretic. In particular, we do not make use of public key encryption, which was required in all previous works...... into the model and to construct schemes that are provably secure within them. We design a general compiler that transforms any cryptographic scheme, e.g., a block-cipher, into a functionally equivalent scheme which is resilient to any continual leakage provided that the following three requirements are satisfied...

  6. Markovian Processes for Quantitative Information Leakage

    DEFF Research Database (Denmark)

    Biondi, Fabrizio

    Quantification of information leakage is a successful approach for evaluating the security of a system. It models the system to be analyzed as a channel with the secret as the input and an output as observable by the attacker as the output, and applies information theory to quantify the amount...... and randomized processes with Markovian models and to compute their information leakage for a very general model of attacker. We present the QUAIL tool that automates such analysis and is able to compute the information leakage of an imperative WHILE language. Finally, we show how to use QUAIL to analyze some...... of information transmitted through such channel, thus effectively quantifying how many bits of the secret can be inferred by the attacker by analyzing the system’s output. Channels are usually encoded as matrices of conditional probabilities, known as channel matrices. Such matrices grow exponentially...

  7. Reactor coolant pressure boundary leakage detection system

    International Nuclear Information System (INIS)

    Dissing, E.; Svansson, L.

    1980-01-01

    This study deals with a system for monitoring the leakage of reactor coolant. This system is based primarily on the detection of the 13 N content in the containment atmosphere. 13 N is produced from the oxygen of the reactor water via the recoil proton nuclear process Hl+016/yields/ 13 N+ 4 He. The generation is therefore independent of fuel element leakage and of the corrosion product content in the water. It is solely related to the neutron flux level in the reactor core. Typical figures for the equilibrium 13 N concentration in the containment atmosphere following a 4 kg/minute coolant leakage are 5 kBq m/sup -3/ and 7 kBq m/sup -3/ for BWR and PWR respectively. These levels are readily measured with a 10 liter Ge(Li) flow detector assembly operated at elevated pressure. 8 refs

  8. Reactor coolant pressure boundary leakage detection system

    International Nuclear Information System (INIS)

    Dissing, E.; Svansson, L.

    1980-01-01

    This study deals with a system for monitoring the leakage of reactor coolant. This system is based primarily on the detection of the N13 content in the containment atmosphere. N13 is produced from the oxygen of the reactor water via the recoil proton nuclear process Hl+016/yields/Nl3+He4. The generation is therefore independent of fuel element leakage and of the corrosion product content in the water. It is solely related to the neutron flux level in the reactor core. Typical figures for the equilibrium N13 concentration in the containment atmosphere following a 4 kg/minute coolant leakage are 5 kBq m/sup -3/ and 7 kBq m/sup -3/ for BWR and PWR respectively. These levels are readily measured with a 10 liter Ge(Li) flow detector assembly operated at elevated pressure. 8 refs

  9. Reactor coolant pressure boundary leakage detection system

    International Nuclear Information System (INIS)

    Dissing, E.; Svansson, L.

    1979-08-01

    The present paper deals with a system for monitoring the leakage of reactor coolant. This system is based primarily on the detection of the N13 content in the containment atmosphere. N13 is produced from the oxygen of the reactor water via the recoil proton nuclear process H1+016 → N13+He4. The generation is therefore independent of fuel element leakage and of the corrosion product content in the water. It is solely related to the neutron flux level in the reactor core. Typical figures for the equilibrium N13 concentration in the containment atmosphere following a 4 kg/minute coolant leakage are 5 kBq m -3 and 7 kBq m -3 for BWR and PWR respectively. These levels are readily measured with a 10 liter Ge (Li) flow detector assembly operated at elevated pressure. (Auth.)

  10. Noise and Hearing Protection

    Science.gov (United States)

    ... ENTCareers Marketplace Find an ENT Doctor Near You Noise and Hearing Protection Noise and Hearing Protection Patient ... it is. How can I tell if a noise is dangerous? People differ in their sensitivity to ...

  11. Genes and Hearing Loss

    Science.gov (United States)

    ... ENTCareers Marketplace Find an ENT Doctor Near You Genes and Hearing Loss Genes and Hearing Loss Patient ... mutation may only have dystopia canthorum. How Do Genes Work? Genes are a road map for the ...

  12. Buying a Hearing Aid

    Science.gov (United States)

    ... the aids? Start using your hearing aids in quiet surroundings, gradually building up to noisier environments. Then eventually work up to wearing your hearing aids all waking hours. Keep a diary to help you remember your ...

  13. OI Issues: Hearing Loss

    Science.gov (United States)

    ... signals normally to the brain. In addition, hearing losses are classified according to the degree of severity: • Mild, • Moderate, • Severe, • Profound. Hearing losses are also classified according to the sound frequency ...

  14. Hearing Loss: Screening Newborns

    Science.gov (United States)

    ... of this page please turn JavaScript on. Feature: Hearing Loss Screening Newborns Past Issues / Spring 2015 Table ... deafness, which account for most cases. Screening Newborns' Hearing Now Standard In 1993, children born in the ...

  15. Hearing and the cochlea

    Science.gov (United States)

    ... like structure that contains the receptor organ for hearing. The cochlea contains the spiral organ of Corti, which is the receptor organ for hearing. It consists of tiny hair cells that translate ...

  16. Occupational hearing loss

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/001048.htm Occupational hearing loss To use the sharing features on this page, please enable JavaScript. Occupational hearing loss is damage to the inner ear from noise ...

  17. Numerical and experimental study of the leakage flow in guide vanes with different hydrofoils

    Directory of Open Access Journals (Sweden)

    Sailesh Chitrakar

    2017-07-01

    Full Text Available Clearance gaps between guide vanes and cover plates of Francis turbines tend to increase in size due to simultaneous effect of secondary flow and erosion in sediment affected hydropower plants. The pressure difference between the two sides of the guide vane induces leakage flow through the gap. This flow enters into the suction side with high acceleration, disturbing the primary flow and causing more erosion and losses in downstream turbine components. A cascade rig containing a single guide vane passage has been built to study the effect of the clearance gap using pressure sensors and PIV (Particle Image Velocimetry technique. This study focuses on developing a numerical model of the test rig, validating the results with experiments and investigating the behavior of leakage flow numerically. It was observed from both CFD and experiment that the leakage flow forms a passage vortex, which shifts away from the wall while travelling downstream. The streamlines contributing to the formation of this vortex have been discussed. Furthermore, the reference guide vane with symmetrical hydrofoil has been compared with four cambered profiles, in terms of the guide vane loading and the consequent effect on the leakage flow. A dimensionless term called Leakage Flow Factor (Lff has been introduced to compare the performances of hydrofoils. It is shown that the leakage flow and its effect on increasing losses and erosion can be minimized by changing the pressure distribution over the guide vane.

  18. Quantifying information leakage of randomized protocols

    DEFF Research Database (Denmark)

    Biondi, Fabrizio; Legay, Axel; Malacaria, Pasquale

    2015-01-01

    The quantification of information leakage provides a quantitative evaluation of the security of a system. We propose the usage of Markovian processes to model deterministic and probabilistic systems. By using a methodology generalizing the lattice of information approach we model refined attackers...... capable to observe the internal behavior of the system, and quantify the information leakage of such systems. We also use our method to obtain an algorithm for the computation of channel capacity from our Markovian models. Finally, we show how to use the method to analyze timed and non-timed attacks...

  19. Quantifying Information Leakage of Randomized Protocols

    DEFF Research Database (Denmark)

    Biondi, Fabrizio; Wasowski, Andrzej; Legay, Axel

    2013-01-01

    The quantification of information leakage provides a quantitative evaluation of the security of a system. We propose the usage of Markovian processes to model and analyze the information leakage of deterministic and probabilistic systems. We show that this method generalizes the lattice...... of information approach and is a natural framework for modeling refined attackers capable to observe the internal behavior of the system. We also use our method to obtain an algorithm for the computation of channel capacity from our Markovian models. Finally, we show how to use the method to analyze timed...

  20. Experimental evaluation of clinical colon anastomotic leakage

    DEFF Research Database (Denmark)

    Pommergaard, Hans-Christian

    2014-01-01

    , whereas the eight-suture control anastomoses had a 0% leakage rate. Furthermore, the use of absorbable suture together with voluntarily ingested Temgesic in chocolate spread as analgesic regimen were feasible. This model may be used to test the leakage reducing potential of coating materials. STUDY 3...... experimental, in which designs were not comparable and many results were contradictory. In a clinical study, a non-significant benefit of fibrin sealant was found. Based on the available clinical and experimental data it was concluded that the fibrin-based sealants, such as Tisseel and Tachosil...

  1. The Leakage determination on corrosion fretting machine

    International Nuclear Information System (INIS)

    Sriyono; Satmoko, Ari; Hafid, Abdul; Febrianto; Prasetio, Joko; Abtokhi; Sumarno, Edy; Handoyo, Ismu; Hidayati, Nur Rahmah; Histori

    1998-01-01

    Fretting machine is an experimental loop to learn fretting corrosion phenomena wich is caused by loading and vibration. On the steam generator, one of the corrosion process that's occurred, it can be caused by vibration between tubes and bending material. Because of high flow rate inside the tube, the high frequency vibration will appeared so it can make the corrosion on bending material more faster. This process can be simulate by fretting machine. This machine has already damage because of leakage. So it will be repaired by dismantling, radiography testing and redrawing. from the result of radiography, the leakage is caused by cracking on bellows seals of the dynamic main support

  2. International hearing protector standardization

    DEFF Research Database (Denmark)

    Poulsen, Torben

    2002-01-01

    Hearing protectors shall fulfill some minimum requirements to their performance. As hearing protector manufacturers sell the products all over the world, the testing and certification of hearing protectors has become an international issue. The ISO working group WG17 under the headlines Acoustics...

  3. Hearing Aids Communication

    DEFF Research Database (Denmark)

    Globally, hearing loss is the second most frequent disability. About 80% of the persons affected by hearing loss do not use hearing aids. The goal of this edited volume is to present a theoretically founded, interdisciplinary approach geared at understanding and improving social interaction...

  4. Deafness and Hearing Loss.

    Science.gov (United States)

    National Information Center for Children and Youth with Disabilities, Washington, DC.

    This brief overview provides information on the definition, incidence, and characteristics of children with hearing impairments and deafness. The federal definitions of hearing impairment and deafness are provided. The different types of hearing loss are noted, including: (1) conductive (caused by diseases or obstructions in the outer or middle…

  5. Hearing poorly with skill

    DEFF Research Database (Denmark)

    Day, Dennis

    2012-01-01

    This paper offers an account of ongoing research into hearing. I offer a characterization of 'skil- led practitioners' from an Ethnomethodological perspective. The skilled practitioner in question is a generic 'hard of hearing' person. The ambition is that such a characterization, both in its...... making and its final state, may be an intrinsic part of design practices concerning the development of hearing aids....

  6. Using the Extended Parallel Process Model to create and evaluate the effectiveness of brochures to reduce the risk for noise-induced hearing loss in college students

    Directory of Open Access Journals (Sweden)

    Michael R Kotowski

    2011-01-01

    Full Text Available Brochures containing messages developed according to the Extended Parallel Process Model were deployed to increase intentions to use hearing protection for college students. These brochures were presented to one-half of a college student sample, after which a questionnaire was administered to assess perceptions of threat, efficacy, and behavioral intentions. The other half of the sample completed the questionnaire and then received brochures. Results indicated that people receiving the brochure before the questionnaire reported greater perceptions of hearing loss threat and efficacy to use ear plugs when in loud environments, however, intentions to use ear plugs were unchanged. Distribution of the brochure also resulted in greater perceptions of hearing loss threat and efficacy to use over-the-ear headphones when using devices such as MP3 players. In this case, however, intentions to use over-the-ear headphones increased. Results are discussed in terms of future research and practical applications.

  7. Integral leakage rate tests of containments

    International Nuclear Information System (INIS)

    Engel, M.; Siefart, E.; Walter, R.

    1978-01-01

    A method is presented for the integral leakage rate tests of containments. This method, used in conjunction with statistical methods, provides reliable information on the tightness of the containment. This method forms the basis of DIN 25436/KTA 3405. (orig.) [de

  8. Poloidal field leakage optimization in ETE

    Energy Technology Data Exchange (ETDEWEB)

    Shibata, Carlos Shinya; Montes, Antonio

    1996-12-01

    A very simple but efficient numerical algorithm is used to minimize the Ohmic coil field leakage into the plasma region of the tokamak ETE. After few interactions the code provides the positions and the current required for two pairs of compensation coils. Resulting optimum field intensity distribution is presented and commented. (author). 5 refs., 4 figs., 2 tabs.

  9. The concept of leakage in threat assessment.

    Science.gov (United States)

    Meloy, J Reid; O'Toole, Mary Ellen

    2011-01-01

    Leakage in the context of threat assessment is the communication to a third party of an intent to do harm to a target. Third parties are usually other people, but the means of communication vary, and include letters, diaries, journals, blogs, videos on the internet, emails, voice mails, and other social media forms of transmission. Leakage is a type of warning behavior that typically infers a preoccupation with the target, and may signal the research, planning, and implementation of an attack. Nomothetic data suggest that leakage occurs in a majority of cases of attacks on and assassinations of public figures, adult mass murders, adolescent mass murders, and school or campus shootings: very low-frequency, but catastrophic acts of intended and targeted violence. Idiographic or case data illustrate the various permutations of leakage. We discuss the operational importance of the concept, place it in the context of other warning behaviors, emphasize the need for further research, and outline risk management strategies for the mitigation of such acts of violence in both law enforcement and clinical mental health settings. Copyright © 2011 John Wiley & Sons, Ltd.

  10. Secret rate - Privacy leakage in biometric systems

    NARCIS (Netherlands)

    Ignatenko, T.; Willems, F.M.J.

    2009-01-01

    Ahlswede and Csiszár [1993] introduced the concept of secret sharing. In their source model two terminals observe two correlated sequences. It is the objective of the terminals to form a common secret by interchanging a public message (helper data) in such a way that the secrecy leakage is

  11. Radiation leakage in nuclear ship 'MUTSU'

    International Nuclear Information System (INIS)

    Ando, Yoshio; Miyasaka, Shun-ichi; Takeuchi, Kiyoshi.

    1975-01-01

    Associated with the radiation leakage in MUTSU occurred in September 1974, this report reviews the shielding design for MUTSU, radiation measurement and inspection activities by a survey group, and 2 dimensional analysis on the behavior of fast neutrons to shielding based on Ssub(N) codes. In the first part, the purpose and the structure of the primary and the secondary shields of MUTSU are briefly illustrated. In the second part, the progress of the series of affairs is explained, starting from zero power criticality experiment, through discovery of radiation leakage in output-increasing test, sending of a survey group for various measurement and inspection, and finally to the conclusion drawn by the survey group. In the third part, various numerical analyses performed to investigate into the leakage are illustrated with their results. The transport codes used were ANISN, TWOTRAN, SPAN, and PALLAS-2DCY. As a result of those inspection and calculation, it was found that the radiation leakage was due to fast neutrons coming through the gap between the reactor vessel and the primary shield. (Aoki, K.)

  12. Solving the problem of valve stem leakage

    International Nuclear Information System (INIS)

    Dixon, D.F.

    1976-01-01

    Engineering solutions to valve stem leakage, in systems carrying expensive heavy water under pressure, have progressed from changing packing brands (failure) to leak collection (partial success) to elimination of small packed valves and an improved valve packing strategy involving stable packing materials, live Belleville spring-loading of packing, and issuance of a detailed stuffing box specification (success). (E.C.B.)

  13. Poloidal field leakage optimization in ETE

    International Nuclear Information System (INIS)

    Shibata, Carlos Shinya; Montes, Antonio.

    1996-01-01

    A very simple but efficient numerical algorithm is used to minimize the Ohmic coil field leakage into the plasma region of the tokamak ETE. After few interactions the code provides the positions and the current required for two pairs of compensation coils. Resulting optimum field intensity distribution is presented and commented. (author). 5 refs., 4 figs., 2 tabs

  14. Zero leakage quantization scheme for biometric verification

    NARCIS (Netherlands)

    Groot, de J.A.; Linnartz, J.P.M.G.

    2011-01-01

    Biometrics gain increasing interest as a solution for many security issues, but privacy risks exist in case we do not protect the stored templates well. This paper presents a new verification scheme, which protects the secrets of the enrolled users. We will show that zero leakage is achieved if

  15. Acoustic control of sodium leakage in valve gates of NPP

    International Nuclear Information System (INIS)

    Trykov, E.L.; Kovtun, S.N.; Anan'ev, A.A.; Yugov, S.I.

    2014-01-01

    Short description of sodium bench and acoustic investigation results on leakage monitoring of valves DN10 and DN40 are given. It is shown that acoustic method can be used successfully to control the leakages of sodium valves. Leakages on both type of valves increase the acoustic signal dispersion by 2-3 orders. For each type of valve acoustic system of leakage determination allows to conduct the preliminary graduation of signal dispersion on the sodium discharge rate. It make possible not only to record the leakage presence but also to determine the sodium discharge rate through the valve during the leakage [ru

  16. Reactor coolant pump seal leakage monitoring

    International Nuclear Information System (INIS)

    Stevens, D.M.; Spencer, J.W.; Morris, D.J.; James, W.; Shugars, H.G.

    1986-01-01

    Problems with reactor coolant pump seals have historically accounted for a large percentage of unscheduled outages. Studies performed for the Electric Power Research Institute (EPRI) have shown that the replacement of coolant pump seals has been one of the leading causes of nuclear plant unavailability over the last ten years. Failures of coolant pump seals can lead to primary coolant leakage rates of 200-500 gallons per minute into the reactor building. Airborne activity and high surface contamination levels following these failures require a major cleanup effort and increases the time and personnel exposure required to refurbish the pump seals. One of the problems in assessing seal integrity is the inability to accurately measure seal leakage. Because seal leakage flow is normally very small, it cannot be sensed directly with normal flow instrumentation, but must be inferred from several other temperature and flow measurements. In operating plants the leakage rate has been quantified with a tipping-bucket gauge, a device which indicates when one quart of water has been accumulated. The tipping-bucket gauge has been used for most rainfall-intensity monitoring. The need for a more accurate and less expensive gauge has been addressed. They have developed a drop-counter precipitation sensor has been developed and optimized. The applicability of the drop-counter device to the problem of measuring seal leakage is being investigated. If a review of system specification and known drop-counter performance indicates that this method is feasible for measuring seal leak rates, a drop-counter gauge will be fabricated and tested in the laboratory. If laboratory tests are successful the gauge will be demonstrated in a pump test loop at Ontario Hydro and evaluated under simulated plant conditions. 3 references, 2 figures

  17. Noise-Induced Hearing Loss

    Science.gov (United States)

    ... can have profound, negative effects on speech, language comprehension, communication, classroom learning, and social development. Studies indicate ... very loud sound, blast, or impulse, or from listening to loud sounds over an extended period. Preventing ...

  18. Mild Maternal Iron Deficiency Anemia Induces Hearing Impairment Associated with Reduction of Ribbon Synapse Density and Dysregulation of VGLUT3, Myosin VIIa, and Prestin Expression in Young Guinea Pigs.

    Science.gov (United States)

    Yu, Fei; Hao, Shuai; Yang, Bo; Zhao, Yue; Zhang, Wenyue; Yang, Jun

    2016-05-01

    Mild maternal iron deficiency anemia (IDA) adversely affects the development of cochlear hair cells of the young offspring, but the mechanisms underlying the association are incompletely understood. The aim of this study was to evaluate whether mild maternal IDA in guinea pigs could interrupt inner hair cell (IHC) ribbon synapse density and outer hair cell motility of the offspring. Here, we established a dietary restriction model that allows us to study quantitative changes in the number of IHC ribbon synapses and hearing impairment in response to mild maternal IDA in young guinea pig. The offspring were weaned on postnatal day (PND) 9 and then were given the iron-sufficient diet. On PND 24, pups were examined the hearing function by auditory brainstem response (ABR) and distortion product otoacoustic emission (DPOAE) measurements. Then, the cochleae were harvested for assessment of the number of IHC ribbon synapses by immunofluorescence, the morphology of cochlear hair cells, and spiral ganglion cells (SGCs) by scanning electron microscope and hematoxylin-eosin staining, the location, and expression of vesicular glutamate transporter (VGLUT) 3, myosin VIIa, and prestin by immunofluorescence and blotting. Here, we show that mild maternal IDA in guinea pigs induced elevated ABR threshold shifts, declined DPOAE level shifts, and reduced the number of ribbon synapses, impaired the morphology of cochlear hair cells and SGCs in offsprings. In addition, downregulation of VGLUT3 and myosin VIIa, and upregulation of prestin were observed in the cochlea of offsprings from mild maternal IDA in guinea pigs. These data indicate that mild maternal IDA in guinea pigs induced hearing impairment in offsprings, and this deficit may be attributed to the reduction of ribbon synapse density and dysregulation of VGLUT3, myosin VIIa, and prestin.

  19. A Role of Medial Olivocochlear Reflex as a Protection Mechanism from Noise-Induced Hearing Loss Revealed in Short-Practicing Violinists.

    Directory of Open Access Journals (Sweden)

    Sho Otsuka

    Full Text Available Previous studies have indicated that extended exposure to a high level of sound might increase the risk of hearing loss among professional symphony orchestra musicians. One of the major problems associated with musicians' hearing loss is difficulty in estimating its risk simply on the basis of the physical amount of exposure, i.e. the exposure level and duration. The aim of this study was to examine whether the measurement of the medial olivocochlear reflex (MOCR, which is assumed to protect the cochlear from acoustic damage, could enable us to assess the risk of hearing loss among musicians. To test this, we compared the MOCR strength and the hearing deterioration caused by one-hour instrument practice. The participants in the study were music university students who are majoring in the violin, whose left ear is exposed to intense violin sounds (broadband sounds containing a significant number of high-frequency components during their regular instrument practice. Audiogram and click-evoked otoacoustic emissions (CEOAEs were measured before and after a one-hour violin practice. There was a larger exposure to the left ear than to the right ear, and we observed a left-ear specific temporary threshold shift (TTS after the violin practice. Left-ear CEOAEs decreased proportionally to the TTS. The exposure level, however, could not entirely explain the inter-individual variation in the TTS and the decrease in CEOAE. On the other hand, the MOCR strength could predict the size of the TTS and CEOAE decrease. Our findings imply that, among other factors, the MOCR is a promising measure for assessing the risk of hearing loss among musicians.

  20. Influence of heat shock on germination Na/sup +/ and K/sup +/ leakage and electrical conductivity of imbibed calligonum seeds

    International Nuclear Information System (INIS)

    Ren, J.; Tao, L.

    2016-01-01

    Relationships between mineral leakage and germination characteristics of five Calligonum seed in teat shock treatments were analyzed. The results suggested that heat shock stress for imbibing seeds significantly inhabited the germination and K+ leakage, and induced more seed transform death. The greater EC induced decreasing of germination of five Calligonum species, and seeds with more leakage of K+ performed greater germinability. Increasing of EC and Na+ leakage induced more seed dead. Na+ leakage and EC of germination medium always increased with temperature. K+ in seeds inhabited germination, Na+ in seeds determined the vigor of Calligonum seeds. Na+/K+ and EC both could be considered to be used for indications of seed vigor of Calligonum seeds. (author)

  1. Pancreatic anastomosis leakage management following pancreaticoduodenectomy how could be manage the anastomosis leakage after pancreaticoduodenectomy?

    Directory of Open Access Journals (Sweden)

    Seyed Abbas Tabatabei

    2015-01-01

    Full Text Available Background: Pancreatic anastomosis leakage and fistula formation following pancreaticoduodenectomy (Whipple′s procedure is a common complication. Delay in timely diagnosis and proper management is associated with high morbidity and mortality. To report our experience with management of pancreatic fistula following Whipple′s procedure. Materials and Methods: In this retrospective study, medical records of 90 patients who underwent Whipple′s procedure from 2009 to 2013 at our medical center were reviewed for documents about pancreatic anastomosis leakage and fistula formation. Results: There were 15 patients who developed pancreatico-jejunal anastomosis leakage. In 6 patients (3 males and 3 females the leakage was mild (conservative therapy was administered, but in 9 patients (6 males and 3 females, there was severe leakage. For the latter group, surgical intervention was done (2 cases underwent re-anastomosis and for 7 cases pancreatico-jejunal stump ligation was done along with drainage of the location. Conclusion: In severe pancreatic anastomotic leakage, it is better to intervene surgically as soon as possible by debridement of the distal part of the pancreas and ligation of the stump with nonabsorbable suture. Furthermore, debridement of the jejunum should be done, and the stump should be ligated thoroughly along with drainage.

  2. Incidence and management of pancreatic leakage after pancreatoduodenectomy

    NARCIS (Netherlands)

    de Castro, S. M. M.; Busch, O. R. C.; van Gulik, T. M.; Obertop, H.; Gouma, D. J.

    2005-01-01

    Background: Optimal management of severe pancreatic leakage after pancreatoduodenectomy can reduce morbidity and mortality. Completion pancreatectomy may be adequate but leads to endocrine insufficiency. This study evaluated an alternative management strategy for pancreatic leakage. Methods: Outcome

  3. Multiple leakage localization and leak size estimation in water networks

    NARCIS (Netherlands)

    Abbasi, N.; Habibi, H.; Hurkens, C.A.J.; Klabbers, M.D.; Tijsseling, A.S.; Eijndhoven, van S.J.L.

    2012-01-01

    Water distribution networks experience considerable losses due to leakage, often at multiple locations simultaneously. Leakage detection and localization based on sensor placement and online pressure monitoring could be fast and economical. Using the difference between estimated and measured

  4. Music and hearing aids.

    Science.gov (United States)

    Madsen, Sara M K; Moore, Brian C J

    2014-10-31

    The signal processing and fitting methods used for hearing aids have mainly been designed to optimize the intelligibility of speech. Little attention has been paid to the effectiveness of hearing aids for listening to music. Perhaps as a consequence, many hearing-aid users complain that they are not satisfied with their hearing aids when listening to music. This issue inspired the Internet-based survey presented here. The survey was designed to identify the nature and prevalence of problems associated with listening to live and reproduced music with hearing aids. Responses from 523 hearing-aid users to 21 multiple-choice questions are presented and analyzed, and the relationships between responses to questions regarding music and questions concerned with information about the respondents, their hearing aids, and their hearing loss are described. Large proportions of the respondents reported that they found their hearing aids to be helpful for listening to both live and reproduced music, although less so for the former. The survey also identified problems such as distortion, acoustic feedback, insufficient or excessive gain, unbalanced frequency response, and reduced tone quality. The results indicate that the enjoyment of listening to music with hearing aids could be improved by an increase of the input and output dynamic range, extension of the low-frequency response, and improvement of feedback cancellation and automatic gain control systems. © The Author(s) 2014.

  5. Music and Hearing Aids

    Directory of Open Access Journals (Sweden)

    Sara M. K. Madsen

    2014-10-01

    Full Text Available The signal processing and fitting methods used for hearing aids have mainly been designed to optimize the intelligibility of speech. Little attention has been paid to the effectiveness of hearing aids for listening to music. Perhaps as a consequence, many hearing-aid users complain that they are not satisfied with their hearing aids when listening to music. This issue inspired the Internet-based survey presented here. The survey was designed to identify the nature and prevalence of problems associated with listening to live and reproduced music with hearing aids. Responses from 523 hearing-aid users to 21 multiple-choice questions are presented and analyzed, and the relationships between responses to questions regarding music and questions concerned with information about the respondents, their hearing aids, and their hearing loss are described. Large proportions of the respondents reported that they found their hearing aids to be helpful for listening to both live and reproduced music, although less so for the former. The survey also identified problems such as distortion, acoustic feedback, insufficient or excessive gain, unbalanced frequency response, and reduced tone quality. The results indicate that the enjoyment of listening to music with hearing aids could be improved by an increase of the input and output dynamic range, extension of the low-frequency response, and improvement of feedback cancellation and automatic gain control systems.

  6. Interventions to promote the wearing of hearing protection

    NARCIS (Netherlands)

    El Dib, R. P.; Verbeek, J.; Atallah, A. N.; Andriolo, R. B.; Soares, B. G. O.

    2006-01-01

    Background Noise induced hearing loss can only be prevented by eliminating or lowering noise exposure levels. Where the source of the noise can not be eliminated workers have to rely on hearing protective equipment. Several trials have been conducted to study the effectiveness of interventions to

  7. Hearing Impairment Caused by Occupational Noise | Mets | South ...

    African Journals Online (AJOL)

    Occupational noise-induced hearing impairment is an insidiously developing injury which only becomes apparent when it affects the hearing of conversational speech. As no remedy is possible, prevention is the only answer. In view of the impending legislation in South Africa a review of the literature is presented. This is ...

  8. Better than fish on land? Hearing across metamorphosis in salamanders

    DEFF Research Database (Denmark)

    Christensen, Christian Bech; Lauridsen, Henrik; Christensen-Dalsgaard, Jakob

    2015-01-01

    hearing in early tetrapods. Here, we combine imaging techniques with neurophysiological measurements to resolve how the change from aquatic larvae to terrestrial adult affects the ear morphology and sensory capabilities of salamanders. We show that air-induced pressure detection enhances underwater...... hearing sensitivity of salamanders at frequencies above 120 Hz, and that both terrestrial adults and fully aquatic juvenile salamanders can detect airborne sound. Collectively, these findings suggest that early atympanic tetrapods may have been pre-equipped to aerial hearing and are able to hear airborne...

  9. Detection method of internal leakage from valve using acoustic method

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi; Kitajima, Akira; Suzuki, Akio.

    1990-01-01

    The objective of this study is to estimate the feasibility of the acoustic method for the internal leakage from the valves in power plants. From the experimental results, it was suggested that the acoustic method for the monitoring of leakage was feasible. When the background levels are higher than the acoustic signals from leakage, we can detect the leakage analyzing the spectrum of the remainders which take the background noise from the acoustic signals. (author)

  10. Hearing loss in relation to sound exposure of professional symphony orchestra musicians

    DEFF Research Database (Denmark)

    Schmidt, J. H.; Pedersen, E. R.; Paarup, H. M.

    2014-01-01

    OBJECTIVES: The objectives of this study were to: (1) estimate the hearing status of classical symphony orchestra musicians and (2) investigate the hypothesis that occupational sound exposure of symphony orchestra musicians leads to elevated hearing thresholds. DESIGN: The study population compri...... that performing music may induce hearing loss to the same extent as industrial noise....

  11. Performance-based containment leakage testing

    International Nuclear Information System (INIS)

    Cybulskis, P.

    1995-01-01

    The U.S. Nuclear Regulatory Commission (NRC) is reviewing regulatory requirements in an effort to revise those that are marginal to safety but impose significant burdens on licensees. Identification of requirements marginal to safety and development and evaluation of alternatives utilize the NRC safety goals and insights from probabilistic risk assessments (PRAs). Since earlier studies found design-basis containment leakage to be a minor contributor to reactor accident risk, containment leakage testing has been selected as a candidate for change in regulations. This paper summarizes the technical analyses supporting the NRC proposal to amend Appendix J of 10 CFR Part 50 as its first effort to decrease unnecessary regulatory burdens on licensees

  12. Methane leakage in natural gas operations

    International Nuclear Information System (INIS)

    Jennervik, A.

    1992-01-01

    The world gas industry is efficient in conservation of natural gas within its systems. As the influence of methane as an infra-red absorbent gas has been more widely recognized, the considerations of methane's greenhouse effect has become vitally important to gas companies around the world. The industry is universally environmentally conscious. natural gas transmission and distribution companies want to maintain their image as suppliers of clean fuel. Further reductions in methane leakage --- particularly in older distribution systems --- can, should and will be pursued. Unfortunately, there has been little exchange of views on methane leakages between commentators on environmental matters and gas companies and organizations. There is absolutely no need for the industry to avoid the issue of greenhouse gases. Without industry involvement, the environmental debate concerning fossil fuels could lead to selective interpretation of scientific views and available evidence. Companies and authorities would be presented with confusing, contradictory evidence on which to base policy approaches and regulations

  13. Plasma membrane damage detected by nucleic acid leakage

    International Nuclear Information System (INIS)

    Fortunati, E.; Bianchi, V.

    1989-01-01

    Among the indicators of membrane damage, the leakage of intracellular components into the medium is the most directly related to the perturbations of the membrane molecular organization. The extent of the damage can be evaluated from the size of the released components. We have designed a protocol for the detection of membrane leakage based on the preincubation of cells with tritiated adenine for 24 h, followed by a 24-h chase in nonradioactive medium. The treatment takes place when the distribution of the precursor among its end products has reached the plateau, and thus the differences of radioactivity in the fractions obtained from the control and treated cultures (medium, nucleotide pool, RNA, DNA) correspond to actual quantitative variations induced by the test chemical. Aliquots of the medium are processed to determine which percentage of the released material is macromolecular, in order to distinguish between mild and severe membrane damage. The origin of the extracellular radioactivity can be recognized from the variations of RNA counts in the treated cells. DNA radioactivity is used to evaluate the number of cells that remain attached to the plates in the different conditions of treatment. By this means, generalized permeabilization of membranes to macromolecules is distinguished from complete solubilization of only a subpopulation of cells. We present some examples of application of the protocol with detergents (LAS, SDS, Triton X-100) and with Cr(VI), which damages cell membranes by a different mechanism of action

  14. Questionnaire investigation of musicians’ use of hearing protectors, self reported hearing disorders and their experience of their working environment

    DEFF Research Database (Denmark)

    Laitinen, Heli; Poulsen, Torben

    2008-01-01

    Musicians in symphony orchestras are exposed to harmful sound levels. Although research shows that industrial workers have a higher propensity to noise induced hearing loss, musicians can also develop a hearing loss from noise exposure. Furthermore, musicians can suffer from tinnitus, hyperacusis...

  15. Air-steam leakage through cracks in concrete

    International Nuclear Information System (INIS)

    Georges Nahas; Helene Simon

    2005-01-01

    axial load is applied on the reinforcement bars for cracking. In this experiment, about five almost plane vertical traversing cracks are induced. Air-steam pressure is applied in a chamber at the top of the slab. Water leakage is collected at the bottom and measured. A scenario lasting 40 hours is produced with a 4 hour temperature stage at 210 Celsius degrees followed by a 4 hour temperature stage at 160 Celsius degrees. During the experiment, the average crack opening is kept constant at the bottom of the slab by changing the applied axial load. At the top, the concrete slab is heated by heat exchange with the steam in the pressure chamber and thermal expansion of the concrete causes the cracks to close during the first stage and reopen during the following stage. A mechanical calculation with the code CAST3M aims to reproduce the mechanical behavior of the slab during the test, namely closing and reopening of the cracks at the top of the slab, where openings are measured. The model represents the five idealized cracks in bidimensional analysis with real test conditions (pressure and thermal load). The mechanical calculation furnishes data needed by the leakage calculation and unreachable to the experiment that are the internal crack profiles ( variation of the opening with the curvilinear coordinate of the crack inside the concrete slab). Various leakage calculations have been performed: linear internal crack profile with inlet crack opening varying with time, complex internal crack profile given by mechanical calculation, and finally mechanics and thermal hydraulics coupling. (authors)

  16. Measurement Methods to Determine Air Leakage Between Adjacent Zones

    Energy Technology Data Exchange (ETDEWEB)

    Hult, Erin L. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Dickerhoff, Darryl J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Price, Phillip N. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-09-01

    Air leakage between adjacent zones of a building can lead to indoor air quality and energy efficiency concerns, however there is no existing standard for measuring inter-zonal leakage. In this study, synthesized data and field measurements are analyzed in order to explore the uncertainty associated with different methods for collecting and analyzing fan pressurization measurements to calculate interzone leakage.

  17. Numerical investigation of tip leakage vortex

    OpenAIRE

    Fredriksen, Vegard

    2017-01-01

    The Kaplan turbine has a small clearance gap between the blade tip and casing to allow the blades to rotate freely. This clearance gap is the cause of an undesirable Tip Leakage Vortex (TLV). A TLV might reduce the turbine efficiency, erode the turbine blades or cause instabilities for the power output. A literature study indicated that the tip clearance gap was a critical parameter affecting the behavior of the TLV. A research gap was observed for an operating Kaplan turbine where the ...

  18. [Hearing loss associated with smoking in male workers].

    Science.gov (United States)

    Takata, Yasumitsu

    2011-03-01

    A cross-sectional study was designed to examine the effect of smoking habit on hearing loss at 1000 and 4000 Hz in the workplace. Among 1,875 male workers, including 287 subjects with occupational noise exposure, the ratio of the number with hearing loss at 1000 or 4000 Hz increased with smoking habits and that relation at 4000 Hz was statistically significant. These hearing losses showed a significant relation with age but not with working- duration under occupational noise exposure by multiple regression analysis. The amount of smoking showed a weak but significant association with hearing loss at 4000 Hz. However, among the 287 male subjects with occupational noise exposure, there was no significant relation between smoking habits and hearing loss. Therefore, both hearing loss induced by occupational noise exposure and that related with smoking habit were well controlled in this workplace. These results indicate that hearing check-ups and education to prevent noise-induced hearing impairment in the workplace might be useful to prevent the hearing loss associated with smoking habit among male workers.

  19. Time reversal technique for gas leakage detection.

    Science.gov (United States)

    Maksimov, A O; Polovinka, Yu A

    2015-04-01

    The acoustic remote sensing of subsea gas leakage traditionally uses sonars as active acoustic sensors and hydrophones picking up the sound generated by a leak as passive sensors. When gas leaks occur underwater, bubbles are produced and emit sound at frequencies intimately related to their sizes. The experimental implementation of an acoustic time-reversal mirror (TRM) is now well established in underwater acoustics. In the basic TRM experiment, a probe source emits a pulse that is received on an array of sensors, time reversed, and re-emitted. After time reversal, the resulting field focuses back at the probe position. In this study, a method for enhancing operation of the passive receiving system has been proposed by using it in the regime of TRM. Two factors, the local character of the acoustic emission signal caused by the leakage and a resonant nature of the bubble radiation at their birth, make particularly effective scattering with the conjugate wave (CW). Analytical calculations are performed for the scattering of CW wave on a single bubble when CW is formed by bubble birthing wail received on an array, time reversed, and re-emitted. The quality of leakage detection depends on the spatio-temporal distribution of ambient noise.

  20. Hearing aid adjustment

    DEFF Research Database (Denmark)

    Heinemann, Trine; Matthews, Ben; Raudaskoski, Pirkko Liisa

    2012-01-01

    to the interaction during hearing aid fitting. This report of a Danish pilot study describes two such problems. The first problem arises from the requirement that the audiologist needs to ‘translate’ the patient’s subjective hearing description for making technological decisions. The second problem is the way...... in which the hearing aid user’s implicit and often unrealistic expectations are handled. This kind of research has potential application for developing a model of best practices....

  1. Contralateral White Noise-Induced Enhancement in the Guinea PigÕs MLR: A Possible Link to Direc- tional Hearing

    OpenAIRE

    GÖKSOY, Cüneyt

    2000-01-01

    The evoked potential components in a time window of 10-50 ms following an acoustic stimulus are called middle latency responses (MLRs). It is known that an amplitude enlargement occurs in guinea pig MLRs to monaural clicks when continuous white noise is applied to the other ear. This study was undertaken to see whether this enlargement is due simply to an overall, generalised effect of contralateral white noise (WN), or whether it may have some connection to directional hearing. Re...

  2. Hearing Conservation Live #2430

    Energy Technology Data Exchange (ETDEWEB)

    Chochoms, Michael [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-08-09

    Occupational hearing loss is one of the most common work-related illnesses in the United States (US). From 22 to 30 million US workers are exposed to hazardous noise levels at work, and 25% of these workers will develop permanent hearing loss. Hearing loss from noise is slow and painless, and you can have a disability before you notice it. This course presents the hazards associated with workplace noise, the purpose and elements of the Los Alamos National Laboratory (LANL) Hearing Conservation Program (HCP), and controls that are available to reduce your exposure to hazardous levels of noise.

  3. Occupational hearing loss of market mill workers in the city of Accra, Ghana

    OpenAIRE

    Emmanuel D Kitcher; Grace Ocansey; Benjamin Abaidoo; Alidu Atule

    2014-01-01

    Noise induced hearing loss (NIHL) is an irreversible sensorineural hearing loss associated with exposure to high levels of excessive noise. Prevention measures are not well established in developing countries. This comparative cross sectional study aims to determine the prevalence of hearing loss in both a group of high risk workers and a control group and to assess their knowledge of the effects of noise on hearing health. A total of 101 market mill workers and 103 controls employed within m...

  4. Polymorphisms of heat shock protein 70 genes (HSPA1A, HSPA1B and HSPA1L and susceptibility of noise-induced hearing loss in a Chinese population: A case-control study.

    Directory of Open Access Journals (Sweden)

    Yanhong Li

    Full Text Available Noise-induced hearing loss (NIHL is the second-most frequent form of sensorineural hearing loss. When exposed to the same noise, some workers develop NIHL while others do not, suggesting that NIHL may be associated with genetic factors. To explore the relationship between single nucleotide polymorphisms (SNPs in heat shock protein 70 (HSP70 genes (HSPA1A, HSPA1B and HSPA1L and susceptibility to NIHL in Han Chinese workers exposed to noise, a case-control association study was carried out with 286 hearing loss cases and 286 matched with gender, age, type of work, and exposure time, drawn from a population of 3790 noise-exposed workers. Four SNPs were selected and genotyped. Subsequently, the effects of the alleles and genotypes of the three HSP70 genes (HSPA1A, HSPA1B and HSPA1L on NIHL were analyzed by using a conditional logistic regression. A generalized multiple dimensionality reduction (GMDR was applied to further detect an interaction between the four SNPs. Compared with the combined genotypes CC/TC, carriers of the TT genotype of rs2763979 appeared to show greater susceptibility to NIHL (P = 0.042, adjusted OR = 1.731, 95% CI 1.021-2.935. A significant interaction between rs2763979 and CNE was found (P = 0.029, and a significant association was found between TT of s2763979 and NIHL (P = 0.024, adjusted OR = 5.694, 95%CI 1.256-25.817 in the 96 dB (A≤CNE<101 dB (A group. The results suggest that the rs2763979 locus of the HSP70 genes may be associated with susceptibility to NIHL in Chinese individuals, and other HSP70 genes may also be susceptibility genes for NIHL, but the results must be further replicated in additional independent sample sets.

  5. Alopecia associated with unexpected leakage from electron cone

    Energy Technology Data Exchange (ETDEWEB)

    Wen, B.C.; Pennington, E.C.; Hussey, D.H.; Jani, S.K.

    1989-06-01

    Excessive irradiation due to unexpected leakage was found on a patient receiving electron beam therapy. The cause of this leakage was analyzed and the amount of leakage was measured for different electron beam energies. The highest leakage occurred with a 6 x 6 cm cone using a 12 MeV electron beam. The leakage dose measured along the side of the cone could be as great as 40%. Until the cones are modified or redesigned, it is advised that all patient setups be carefully reviewed to assure that no significant patient areas are in the side scatter region.

  6. Hearing conservation in the South African mining industry [Notes

    CSIR Research Space (South Africa)

    Edwards, A

    2010-09-01

    Full Text Available This paper deals with noise-induced hearing loss protection in the South African mining industry. I deals with several issues, including standards and regulations, medical issues and compensation...

  7. Disruption of ion-trafficking system in the cochlear spiral ligament prior to permanent hearing loss induced by exposure to intense noise: possible involvement of 4-hydroxy-2-nonenal as a mediator of oxidative stress.

    Directory of Open Access Journals (Sweden)

    Taro Yamaguchi

    Full Text Available Noise-induced hearing loss is at least in part due to disruption of endocochlear potential, which is maintained by various K(+ transport apparatuses including Na(+, K(+-ATPase and gap junction-mediated intercellular communication in the lateral wall structures. In this study, we examined the changes in the ion-trafficking-related proteins in the spiral ligament fibrocytes (SLFs following in vivo acoustic overstimulation or in vitro exposure of cultured SLFs to 4-hydroxy-2-nonenal, which is a mediator of oxidative stress. Connexin (Cx26 and Cx30 were ubiquitously expressed throughout the spiral ligament, whereas Na(+, K(+-ATPase α1 was predominantly detected in the stria vascularis and spiral prominence (type 2 SLFs. One-hour exposure of mice to 8 kHz octave band noise at a 110 dB sound pressure level produced an immediate and prolonged decrease in the Cx26 expression level and in Na+, K(+-ATPase activity, as well as a delayed decrease in Cx30 expression in the SLFs. The noise-induced hearing loss and decrease in the Cx26 protein level and Na(+, K(+-ATPase activity were abolished by a systemic treatment with a free radical-scavenging agent, 4-hydroxy-2,2,6,6-tetramethylpiperidine 1-oxyl, or with a nitric oxide synthase inhibitor, N(ω-nitro-L-arginine methyl ester hydrochloride. In vitro exposure of SLFs in primary culture to 4-hydroxy-2-nonenal produced a decrease in the protein levels of Cx26 and Na(+, K(+-ATPase α1, as well as Na(+, K(+-ATPase activity, and also resulted in dysfunction of the intercellular communication between the SLFs. Taken together, our data suggest that disruption of the ion-trafficking system in the cochlear SLFs is caused by the decrease in Cxs level and Na(+, K(+-ATPase activity, and at least in part involved in permanent hearing loss induced by intense noise. Oxidative stress-mediated products might contribute to the decrease in Cxs content and Na(+, K(+-ATPase activity in the cochlear lateral wall structures.

  8. Numerical Investigation of the Interaction between Mainstream and Tip Shroud Leakage Flow in a 2-Stage Low Pressure Turbine

    Science.gov (United States)

    Jia, Wei; Liu, Huoxing

    2014-06-01

    The pressing demand for future advanced gas turbine requires to identify the losses in a turbine and to understand the physical mechanisms producing them. In low pressure turbines with shrouded blades, a large portion of these losses is generated by tip shroud leakage flow and associated interaction. For this reason, shroud leakage losses are generally grouped into the losses of leakage flow itself and the losses caused by the interaction between leakage flow and mainstream. In order to evaluate the influence of shroud leakage flow and related losses on turbine performance, computational investigations for a 2-stage low pressure turbine is presented and discussed in this paper. Three dimensional steady multistage calculations using mixing plane approach were performed including detailed tip shroud geometry. Results showed that turbines with shrouded blades have an obvious advantage over unshrouded ones in terms of aerodynamic performance. A loss mechanism breakdown analysis demonstrated that the leakage loss is the main contributor in the first stage while mixing loss dominates in the second stage. Due to the blade-to-blade pressure gradient, both inlet and exit cavity present non-uniform leakage injection and extraction. The flow in the exit cavity is filled with cavity vortex, leakage jet attached to the cavity wall and recirculation zone induced by main flow ingestion. Furthermore, radial gap and exit cavity size of tip shroud have a major effect on the yaw angle near the tip region in the main flow. Therefore, a full calculation of shroud leakage flow is necessary in turbine performance analysis and the shroud geometric features need to be considered during turbine design process.

  9. Fluorine-plasma surface treatment for gate forward leakage current reduction in AlGaN/GaN HEMTs

    International Nuclear Information System (INIS)

    Chen Wanjun; Zhang Jing; Zhang Bo; Chen, Kevin Jing

    2013-01-01

    The gate forward leakage current in AlGaN/GaN high electron mobility transistors (HEMTs) is investigated. It is shown that the current which originated from the forward biased Schottky-gate contributed to the gate forward leakage current. Therefore, a fluorine-plasma surface treatment is presented to induce the negative ions into the AlGaN layer which results in a higher metal—semiconductor barrier. Consequently, the gate forward leakage current shrinks. Experimental results confirm that the gate forward leakage current is decreased by one order magnitude lower than that of HEMT device without plasma treatment. In addition, the DC characteristics of the HEMT device with plasma treatment have been studied. (semiconductor devices)

  10. Hereditary Hearing Loss.

    Science.gov (United States)

    Tran, LenhAnh P.; Grundfast, Kenneth M.

    1997-01-01

    This article discusses inheritance patterns in hearing loss, epidemiology, clues to genetic causes, locating genes that cause hereditary disorders, genes related to hearing loss disorders in individuals with Usher syndrome, Waardenburg syndrome, Treacher-Collins syndrome, Branchio-oto-renal and Pendred syndromes, and the significance of finding…

  11. The Konrad hearing

    International Nuclear Information System (INIS)

    Thomauske, B.

    1993-01-01

    The paper provides an interim assessment: Attempts to break off early the hearing failed. Neither have significant points be found which would provide a technically motivated reason for reexamination. After the hearing, a positive plan approving decision should be taken as soon as possible. The discussion about the energy-policy consensus will have its effects on this. (orig./HSCH) [de

  12. Age-related Hearing Impairment and the Triad of Acquired Hearing Loss

    Directory of Open Access Journals (Sweden)

    Chao-Hui eYang

    2015-07-01

    Full Text Available Understanding underlying pathological mechanisms is prerequisite for a sensible design of protective therapies against hearing loss. The triad of age-related, noise-generated, and drug-induced hearing loss ¬¬displays intriguing similarities in some cellular responses of cochlear sensory cells such as a potential involvement of reactive oxygen species and apoptotic and necrotic cell death. On the other hand, detailed studies have revealed that molecular pathways are considerably complex and, importantly, it has become clear that pharmacological protection successful against one form of hearing loss will not necessarily protect against another. This review will summarize pathological and pathophysiological features of age-related hearing impairment (ARHI in human and animal models and address selected aspects of the commonality (or lack thereof of cellular responses in ARHI to drugs and noise.

  13. Individual Hearing Loss

    Directory of Open Access Journals (Sweden)

    Sébastien Santurette

    2016-06-01

    Full Text Available It is well-established that hearing loss does not only lead to a reduction of hearing sensitivity. Large individual differences are typically observed among listeners with hearing impairment in a wide range of suprathreshold auditory measures. In many cases, audiometric thresholds cannot fully account for such individual differences, which make it challenging to find adequate compensation strategies in hearing devices. How to characterize, model, and compensate for individual hearing loss were the main topics of the fifth International Symposium on Auditory and Audiological Research (ISAAR, held in Nyborg, Denmark, in August 2015. The following collection of papers results from some of the work that was presented and discussed at the symposium.

  14. Leakage current measurement in transformerless PV inverters

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Sera, Dezso; Mathe, Laszlo

    2012-01-01

    Photovoltaic (PV) installations have seen a huge increase during the last couple of years. Transformerless PV inverters are gaining more share of the total inverter market, due to their high conversion efficiency, small weight and size. Nevertheless safety should have an important role in case...... of these tranformerless systems, due to the missing galvanic isolation. Leakage and fault current measurement is a key issue for these inverter topologies to be able to comply with the required safety standards. This article presents the test results of two different current measurement sensors that were suggested...

  15. Leakage warning system for flexible underwater pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, E; Bernstein, L

    1985-08-01

    Underwater pipelines for unloading oil tankers, e.g. in 30 km distance from the harbour site, are required to be flexible and require supervision. This is done by implementation of oil sensitive sensors between the inner rubber tube and the following impregnated textile layer. The generated sensor signals, influenced by leak oil, have to be wireless transmitted from 150 meters under water to the supervisory station at the coast. Sensor configurations are described, to derive the point of the leakage from the topologized warning signals.

  16. Facepiece leakage and fitting of respirators

    International Nuclear Information System (INIS)

    White, J.M.

    1978-05-01

    The ways in which airborne contaminants can penetrate respirators and the factors which affect the fit of respirators are discussed. The fit of the respirator to the face is shown to be the most critical factor affecting the protection achieved by the user. Qualitative and quantitative fit testing techniques are described and their application to industrial respirator programs is examined. Quantitative measurement of the leakage of a respirator while worn can be used to numerically indicate the protection achieved. These numbers, often referred to as protection factors, are sometimes used as the basis for selecting suitable respirators and this practice is reviewed. (author)

  17. Valve leakage inspection testing and maintenance process

    International Nuclear Information System (INIS)

    Aikin, J.A.; Reinwald, J.W.; Kittmer, C.A.

    1991-01-01

    In valve maintenance, packing rings that prevent leakage along the valve stem must periodically be replaced, either during routine maintenance or to correct a leak or valve malfunction. Tools and procedures currently in use for valve packing removal and inspection are generally of limited value due to various access and application problems. A process has been developed by AECL Research that addresses these problems. The process, using incompressible fluid pressure, quickly and efficiently confirms the integrity of the valve backseat, extracts hard-to-remove valve packing sets, and verifies the leak tightness of the repacked valve

  18. Unusual dialysate leakage complicating peritoneal dialysis

    International Nuclear Information System (INIS)

    Chiu, Jainn-Shiun; Yu, Fu-Chiu; Chen, Chiou-An; Wang, Yuh-Feng

    2006-01-01

    A 16-year-old female who had end-stage renal disease on 2-month continuous ambulatory peritoneal dialysis (CAPD) presented with perineal pain 4 days before admission. The physical examination revealed bilateral labial edema. Peritoneal scintigraphy was requested after infusing 2 L peritoneal dialysate with direct administration of 370 MBq (10mCi) technetium-99m diethylenetriamine pentra-acetic acid into peritoneal cavity via Tenckhoff catheter. Radioactive uptake from right inguinal to labial region was clearly demonstrated, and this indicated the site of peritoneal leakage. After surgical intervention unilaterally, she continued CAPD without any recurrence (au)

  19. Hearing protection use in manufacturing workers: A qualitative study

    Directory of Open Access Journals (Sweden)

    Ravi K Reddy

    2012-01-01

    Full Text Available Occupational noise is a significant contributor to disabling hearing loss worldwide. Noise-induced hearing loss (NIHL has resulted in huge human and economic consequences costing New Zealand approximately $53M annually and rising. A high proportion of hearing loss claims are made by workers in the manufacturing sector. Hearing protection devices (HPDs are used together with engineering and administrative controls to minimize noise exposure and to prevent hearing loss. Unfortunately, inconsistent and improper use of HPDs has hindered efforts to prevent NIHL. The purpose of this study was to understand the factors that influence the use of HPDs amongst a group of manufacturing workers in New Zealand. A purposive sample of twenty-five workers was recruited to take part in semi-structured interviews. The open-ended questions were aimed at exploring the participants′ knowledge, attitude, beliefs, and behavior towards noise and HPDs. The data were analyzed using conventional content analysis and key themes emerged in relation to HPD use. Themes that emerged from the interviews either supported good hearing protection behavior or acted as barriers against it. Five major themes, (perception of noise, hearing preservation, reluctance to use HPDs, workplace interaction, and value of hearing and sub-themes described various factors that influence hearing protection use. Both personal and environmental factors influence the use of HPDs. Based on this study, personal and environmental factors need to be targeted for further research using ecological models to develop interventions that promote HPD use amongst workers.

  20. Occupational noise exposure and hearing: a systematic review.

    Science.gov (United States)

    Lie, Arve; Skogstad, Marit; Johannessen, Håkon A; Tynes, Tore; Mehlum, Ingrid Sivesind; Nordby, Karl-Christian; Engdahl, Bo; Tambs, Kristian

    2016-04-01

    To give a systematic review of the development of noise-induced hearing loss (NIHL) in working life. A literature search in MEDLINE, Embase, Web of Science, Scopus, and Health and Safety Abstracts, with appropriate keywords on noise in the workplace and health, revealed 22,413 articles which were screened by six researchers. A total of 698 articles were reviewed in full text and scored with a checklist, and 187 articles were found to be relevant and of sufficient quality for further analysis. Occupational noise exposure causes between 7 and 21 % of the hearing loss among workers, lowest in the industrialized countries, where the incidence is going down, and highest in the developing countries. It is difficult to distinguish between NIHL and age-related hearing loss at an individual level. Most of the hearing loss is age related. Men lose hearing more than women do. Heredity also plays a part. Socioeconomic position, ethnicity and other factors, such as smoking, high blood pressure, diabetes, vibration and chemical substances, may also affect hearing. The use of firearms may be harmful to hearing, whereas most other sources of leisure-time noise seem to be less important. Impulse noise seems to be more deleterious to hearing than continuous noise. Occupational groups at high risk of NIHL are the military, construction workers, agriculture and others with high noise exposure. The prevalence of NIHL is declining in most industrialized countries, probably due to preventive measures. Hearing loss is mainly related to increasing age.

  1. Factors associated with hearing loss in a normal-hearing guinea pig model of Hybrid cochlear implants.

    Science.gov (United States)

    Tanaka, Chiemi; Nguyen-Huynh, Anh; Loera, Katherine; Stark, Gemaine; Reiss, Lina

    2014-10-01

    quantified in this study. The variation in hearing loss after surgery and electrical stimulation in this animal model is consistent with the variation in human patients. Further, these findings illustrate an advantage of a normal-hearing animal model for quantification of hearing loss and damage to cochlear structures without the confounding effects of chemical- or noise-induced hearing loss. Finally, this study is the first to suggest a role of the stria vascularis and damage to the lateral wall in implantation-induced hearing loss. Further work is needed to determine the mechanisms of implantation- and electrical-stimulation-induced hearing loss. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Hear today, gone tomorrow: an assessment of portable entertainment player use and hearing acuity in a community sample.

    Science.gov (United States)

    Shah, Samit; Gopal, Bharat; Reis, Janet; Novak, Michael

    2009-01-01

    Noise-induced hearing loss (NIHL) is a common but preventable disability. The purpose of this study was to assess the understanding of NIHL in a community sample in the context of exposure to portable music players, including MP3 players, and personal hearing acuity as tested with the Welch Allyn Audioscope 3. A cross-sectional convenience sample of 94 adults (18 to 65 years old) at a university recreation center completed an analysis of personal use of portable digital music players (MP3 players), concerns about hearing loss, and a 3-dB-level hearing test at 4 levels of speech frequency in a low ambient noise setting. The majority of participants (85%) were concerned about hearing loss, willing to protect their hearing with lower volume (77%), had little measurable hearing loss but were exposed to longer and louder periods of noise than other national samples, and mistakenly felt that NIHL is a medically reversible condition. Many (40%) also wanted their family medicine physician to be more concerned about their hearing. Family medicine physicians are in a key position to provide basic information on the preventability and negative consequences of NIHL, as well as to identify and refer patients with identified hearing loss.

  3. Biomembrane Permeabilization: Statistics of Individual Leakage Events Harmonize the Interpretation of Vesicle Leakage

    Czech Academy of Sciences Publication Activity Database

    Braun, S.; Pokorná, Šárka; Šachl, Radek; Hof, Martin; Heerklotz, H.; Hoernke, M.

    2018-01-01

    Roč. 12, č. 1 (2018), s. 813-819 ISSN 1936-0851 R&D Projects: GA ČR GA17-03160S Institutional support: RVO:61388955 Keywords : leakage * dye release * pore Subject RIV: CF - Physical ; Theoretical Chemistry OBOR OECD: Physical chemistry Impact factor: 13.942, year: 2016

  4. Leakage in the Juelich research reactor

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    On August 17, 1978, a leakage occurred in the DIDO research reactor. Early in the afternoon of this day, the valves of the coolant loop had been checked with the reactor shut off. When the mechanics wanted to oil a tight valve and drilled a hole in the valve cover for this, heavy water started to leak (leakage in the valve membrane). The mechanics left the shielded valve space at once; directly after having a shower, they underwent a radiation protection examination. It was found that none of the mechanics had been exposed to an excessive dose. When other mechanics in protective suits had closed the leak in the valve, a total of 150 liters had leaked into the sump pump at the valve entrance. They were pumped back into the cooling system. About 5 liters of water were evaporated and, via the stack, escaped into the environment. The activity released was about 40 curie; this is less than the permissible amount of 60 curie per week during normal operation. Neither the KFA personnel nor the inhabitants of Juelich and its surroundings were in danger at any moment. Calculations so far yield a maximum radiation exposure below 1mrem at the point of maximum exposure. The cooling circuit could be entered again only one day after the incident. The present shut-off phase of the reactor is not unduly prolonged by this accident. (orig./HP) [de

  5. Leakage detection device for weld portion

    International Nuclear Information System (INIS)

    Shinkawa, Toshio; Setokuchi, Sadayuki.

    1994-01-01

    The present invention concerns leakage detection device for weld portions, for example, in a nuclear reactor cavity, which can rapidly detect by remote control. That is, a detection device capable of self running and stopping on a guide rail along a weld line is disposed. The detection device comprises a coating mechanism for automatically coating soap water to the weld portion, a vacuum box capable of evacuating the coated surface and a camera for detecting the presence or absence of the soap bubbles generated under the evacuation. Such a device can conduct, by remote control, self running/stopping along with the weld line, coating of the soap water, settling of the vacuum box and confirmation and recording of foaming by using a television monitor. Accordingly, leakage in the weld portion in the reactor cavity or the like can be inspected. As a result, it greatly contributes to improvement of danger upon worker's operation at high place, detection accuracy and reliability of detection and shortening of operation period. (I.S.)

  6. Leakage detection system in nuclear reactor container

    International Nuclear Information System (INIS)

    Kurosawa, Masahiko.

    1993-01-01

    The present invention comprises an injection means for adding radioactive materials to coolants in a container cooler, a gamma ray amplitude analyzer connected to coolant pipelines and a means for recording/transferring the data of the result of the measurement, a gamma ray amplitude analyzer connected to a drain water sump and a means for recording/transferring the data of the result of the measurement, a gamma ray amplitude analyzer connected to various kinds of pipelines and a means for recording/transferring the data of the result of the measurement, and a data processing means for comparing and analyzing the measured data of each of the gamma ray amplitude analyzers inputted from each of date recording/transferring means. The gamma ray amplitude analysis for each of the pipelines and drain water sump are conducted at an appropriate frequency, and the measured data are compared and analyzed, to improve the detection accuracy for a trace amount of leakage from each of the pressure pipelines and the container cooler coolant pipelines, thereby enabling to specify the pipeline having leakage. Maintenance efficiency is improved, and severe rupture accident in each of pressure pipelines is prevented previously. (N.H.)

  7. Short-term music-induced hearing loss after sound exposure to discotheque music: the effectiveness of a break in reducing temporary threshold shift.

    Science.gov (United States)

    Helleman, Hiske W; Dreschler, Wouter A

    2015-02-01

    To investigate the effect of a break in music exposure on temporary threshold shifts. A cross-over design where subjects are exposed to dance music for either two hours consecutively, or exposed to two hours of dance music with a one-hour break in between. Outcome measure was the change in hearing threshold, measured in 1-dB steps at different time points after ending the music. Eighteen normal-hearing subjects participated in this study. Changes in pure-tone threshold were observed in both conditions and were similar, regardless of the break. Threshold shifts could be averaged for 1000, 2000, and 4000 Hz. The shift immediately after the ending of the music was 1.7 dB for right ears, and 3.4 dB for left ears. The difference between left and right ears was significant. One hour after the exposure, right ears were recovered to baseline conditions whereas left ears showed a small but clinically irrelevant remaining shift of approximately 1 dB. The advice to use chill-out zones is still valid, because this helps to reduce the duration to the exposure. This study does not provide evidence that a rest period gives an additional reduction of temporary threshold shifts.

  8. 78 FR 5556 - Public Hearing

    Science.gov (United States)

    2013-01-25

    ... SUSQUEHANNA RIVER BASIN COMMISSION Public Hearing AGENCY: Susquehanna River Basin Commission. ACTION: Notice. SUMMARY: The Susquehanna River Basin Commission will hold a public hearing on February 14, 2013, in Harrisburg, Pennsylvania. At this public hearing, the Commission will hear testimony on the...

  9. 77 FR 64576 - Public Hearing

    Science.gov (United States)

    2012-10-22

    ... SUSQUEHANNA RIVER BASIN COMMISSION Public Hearing AGENCY: Susquehanna River Basin Commission. ACTION: Notice. SUMMARY: The Susquehanna River Basin Commission will hold a public hearing on November 15, 2012, in Harrisburg, Pennsylvania. At this public hearing, the Commission will hear testimony on the...

  10. 78 FR 43961 - Public Hearing

    Science.gov (United States)

    2013-07-22

    ... SUSQUEHANNA RIVER BASIN COMMISSION Public Hearing AGENCY: Susquehanna River Basin Commission. ACTION: Notice. SUMMARY: The Susquehanna River Basin Commission will hold a public hearing on August 15, 2013, in Harrisburg, Pennsylvania. At this public hearing, the Commission will hear testimony on the...

  11. 77 FR 44703 - Public Hearing

    Science.gov (United States)

    2012-07-30

    ... SUSQUEHANNA RIVER BASIN COMMISSION Public Hearing AGENCY: Susquehanna River Basin Commission. ACTION: Notice. SUMMARY: The Susquehanna River Basin Commission will hold a public hearing on August 23, 2012, in Harrisburg, Pennsylvania. At this public hearing, the Commission will hear testimony on the...

  12. 78 FR 64260 - Public Hearing

    Science.gov (United States)

    2013-10-28

    ... SUSQUEHANNA RIVER BASIN COMMISSION Public Hearing AGENCY: Susquehanna River Basin Commission. ACTION: Notice. SUMMARY: The Susquehanna River Basin Commission will hold a public hearing on November 13, 2013, in Harrisburg, Pennsylvania. At this public hearing, the Commission will hear testimony on the...

  13. Efficient evaluation of hearing ability

    NARCIS (Netherlands)

    2009-01-01

    A system for establishing a hearing ability model of a hearing ability of a person, includes a data storage configured to store a representation of a distribution of a hearing ability of a population of individuals, and a processor configured to establish a hearing ability model representing a

  14. Uncovering effective strategies for hearing loss prevention

    Science.gov (United States)

    Morata, Thais C.; Meinke, Deanna

    2016-01-01

    Occupational health agencies, researchers and policy makers have recognized the need for evidence on the effectiveness of interventions designed to reduce or prevent workplace injuries and illnesses. While many workplaces comply with legal or obligatory requirements and implement recommended interventions, few publications exist documenting the effectiveness of these actions. Additionally, some workplaces have discovered through their own processes, novel ways to reduce the risk of injury. Peer-reviewed information on the effectiveness of the many strategies and approaches currently in use could help correct weaknesses, or further encourage their adoption and expansion. The evaluation of intervention effectiveness would certainly contribute to improved worker health and safety. This need is particularly relevant regarding noise exposure in the workplace and hearing loss prevention interventions. In a 2006 review of the U.S. National Institute for Occupational Safety and Health (NIOSH) Hearing Loss Research Program, the independent National Academies of Sciences recommended that NIOSH place greater emphasis on identifying the effectiveness of hearing loss prevention measures on the basis of outcomes that are as closely related as possible to reducing noise exposure and work related hearing loss (http://www.nap.edu/openbook.php?record_id=11721). NIOSH used two different approaches to address that recommendation: the first one was to conduct research, including broad systematic reviews on the effectiveness of interventions to prevent occupational noise-induced hearing loss. The second was to create an award program, the Safe-In-Sound Excellence in Hearing Loss Prevention Award™, to identify and honor excellent real-world examples of noise control and other hearing loss prevention practices and innovations. PMID:27397968

  15. Calculation of transformers leakage reactance using electromagnetic energy technique

    International Nuclear Information System (INIS)

    Feiz, J.; Mohseni, H.; Sabet Marzooghi, S.; Naderian Jahromi, A.

    2004-01-01

    Determination of transformer leakage reactance using magnetic cores has long been an area of interest to engineers involved in the design of power and distribution transformers. This is required for predicting the performance of transformers before actual assembly of the transformers. In this paper a closed form solution technique applicable to the leakage reactance calculations for transformers is presented. An emphasis is on the development of a simple method to calculate the leakage reactance of the distribution transformers and smaller transformers. Energy technique procedure for computing the leakage reactances in distribution transformers is presented. This method is very efficient compared with the use of flux element and image technique and is also remarkably accurate. Examples of calculated leakage inductances and the short circuit impedance are given for illustration. For validation, the results are compared with the results obtained using test. This paper presents a novel technique for calculation of the leakage inductance in different parts of the transformer using the electromagnetic stored energy

  16. Indocyanine green staining facilitates detection of bleb leakage during trabeculectomy.

    Science.gov (United States)

    Okazaki, Teruhiko; Kiuchi, Takahiro; Kawana, Keisuke; Oshika, Tetsuro

    2007-03-01

    To report a new technique to visualize bleb leakage using indocyanine green (ICG) staining during trabeculectomy. The ICG solution was widely applied over the filtering bleb including the conjunctival wound before completion of trabeculectomy. This procedure was performed in 48 eyes of 44 consecutive patients undergoing trabeculectomy between December 2004 and October 2005. Without staining, bleb leakage was not identified by the direct observation under the operating microscope. ICG staining clearly visualized aqueous leakage from the bleb in 5 eyes (10.4%). The bleb leakage in these eyes was easily repaired with 10-0 nylon sutures, and no eyes, including these 5 cases, showed bleb leakage after surgery. There were no intraoperative and postoperative complications related to ICG application. The application of ICG during trabeculectomy is a simple and useful technique to facilitate detection and repair of the bleb leakage.

  17. Device for preventing leakage of coolant in nuclear fuel assembly

    International Nuclear Information System (INIS)

    Kobayashi, Yukio; Sekiguchi, Mamoru; Yoshida, Hideo.

    1975-01-01

    Object: To prevent leakage of coolant from between lower tie plate and channel box without causing deformation of the channel box and also without the possibility of disturbing the installation and removal of the box by the provision of a thin plate provided with leakage holes for the lower tie plate. Structure: Static water pressure within the lower tie plate is adapted to act upon the bear side of a flat plate for leakage prevention through leakage holes formed in the tie plate, thus urging the flat plate against the channel box inner surface. Meanwhile, static water pressure having been led through the leakage holes in the flat plate is adapted to press the flat plate in the vertical direction, thus urging the flat plate against the channel box inner surface and thereby preventing leakage of the coolant through a gap between the channel box and lower tie plate. (Yoshino, Y.)

  18. Statistical model for prediction of hearing loss in patients receiving cisplatin chemotherapy.

    Science.gov (United States)

    Johnson, Andrew; Tarima, Sergey; Wong, Stuart; Friedland, David R; Runge, Christina L

    2013-03-01

    This statistical model might be used to predict cisplatin-induced hearing loss, particularly in patients undergoing concomitant radiotherapy. To create a statistical model based on pretreatment hearing thresholds to provide an individual probability for hearing loss from cisplatin therapy and, secondarily, to investigate the use of hearing classification schemes as predictive tools for hearing loss. Retrospective case-control study. Tertiary care medical center. A total of 112 subjects receiving chemotherapy and audiometric evaluation were evaluated for the study. Of these subjects, 31 met inclusion criteria for analysis. The primary outcome measurement was a statistical model providing the probability of hearing loss following the use of cisplatin chemotherapy. Fifteen of the 31 subjects had significant hearing loss following cisplatin chemotherapy. American Academy of Otolaryngology-Head and Neck Society and Gardner-Robertson hearing classification schemes revealed little change in hearing grades between pretreatment and posttreatment evaluations for subjects with or without hearing loss. The Chang hearing classification scheme could effectively be used as a predictive tool in determining hearing loss with a sensitivity of 73.33%. Pretreatment hearing thresholds were used to generate a statistical model, based on quadratic approximation, to predict hearing loss (C statistic = 0.842, cross-validated = 0.835). The validity of the model improved when only subjects who received concurrent head and neck irradiation were included in the analysis (C statistic = 0.91). A calculated cutoff of 0.45 for predicted probability has a cross-validated sensitivity and specificity of 80%. Pretreatment hearing thresholds can be used as a predictive tool for cisplatin-induced hearing loss, particularly with concomitant radiotherapy.

  19. Hearing Aid Personalization

    DEFF Research Database (Denmark)

    Nielsen, Jens Brehm; Nielsen, Jakob; Jensen, Bjørn Sand

    2013-01-01

    Modern digital hearing aids require and offer a great level of personalization. Today, this personalization is not performed based directly on what the user actually perceives, but on a hearing-care professional’s interpretation of what the user explains about what is perceived. In this paper......, an interactive personalization system based on Gaussian process regression and active learning is proposed, which personalize the hearing aids based directly on what the user perceives. Preliminary results demonstrate a significant difference between a truly personalized setting obtained with the proposed system...

  20. Mind the gap - tip leakage vortex in axial turbines

    International Nuclear Information System (INIS)

    Dreyer, M; Farhat, M; Decaix, J; Münch-Alligné, C

    2014-01-01

    The tendency of designing large Kaplan turbines with a continuous increase of output power is bringing to the front the cavitation erosion issue. Due to the flow in the gap between the runner and the discharge ring, axial turbine blades may develop the so called tip leakage vortex (TLV) cavitation with negative consequences. Such vortices may interact strongly with the wake of guide vanes leading to their multiple collapses and rebounds. If the vortex trajectory remains close to the blade tip, these collapses may lead to severe erosion. One is still unable today to predict its occurrence and development in axial turbines with acceptable accuracy. Numerical flow simulations as well as the actual scale-up rules from small to large scales are unreliable. The present work addresses this problematic in a simplified case study representing TLV cavitation to better understand its sensitivity to the gap width. A Naca0009 hydrofoil is used as a generic blade in the test section of EPFL cavitation tunnel. A sliding mounting support allowing an adjustable gap between the blade tip and wall was manufactured. The vortex trajectory is visualized with a high speed camera and appropriate lighting. The three dimensional velocity field induced by the TLV is investigated using stereo particle image velocimetry. We have taken into account the vortex wandering in the image processing to obtain accurate measurements of the vortex properties. The measurements were performed in three planes located downstream of the hydrofoil for different values of the flow velocity, the incidence angle and the gap width. The results clearly reveal a strong influence of the gap width on both trajectory and intensity of the tip leakage vortex

  1. Mind the gap - tip leakage vortex in axial turbines

    Science.gov (United States)

    Dreyer, M.; Decaix, J.; Münch-Alligné, C.; Farhat, M.

    2014-03-01

    The tendency of designing large Kaplan turbines with a continuous increase of output power is bringing to the front the cavitation erosion issue. Due to the flow in the gap between the runner and the discharge ring, axial turbine blades may develop the so called tip leakage vortex (TLV) cavitation with negative consequences. Such vortices may interact strongly with the wake of guide vanes leading to their multiple collapses and rebounds. If the vortex trajectory remains close to the blade tip, these collapses may lead to severe erosion. One is still unable today to predict its occurrence and development in axial turbines with acceptable accuracy. Numerical flow simulations as well as the actual scale-up rules from small to large scales are unreliable. The present work addresses this problematic in a simplified case study representing TLV cavitation to better understand its sensitivity to the gap width. A Naca0009 hydrofoil is used as a generic blade in the test section of EPFL cavitation tunnel. A sliding mounting support allowing an adjustable gap between the blade tip and wall was manufactured. The vortex trajectory is visualized with a high speed camera and appropriate lighting. The three dimensional velocity field induced by the TLV is investigated using stereo particle image velocimetry. We have taken into account the vortex wandering in the image processing to obtain accurate measurements of the vortex properties. The measurements were performed in three planes located downstream of the hydrofoil for different values of the flow velocity, the incidence angle and the gap width. The results clearly reveal a strong influence of the gap width on both trajectory and intensity of the tip leakage vortex.

  2. Perda auditiva induzida por ruído e hipertensão em condutores de ônibus Noise-induced hearing loss and high blood pressure among city bus drivers

    Directory of Open Access Journals (Sweden)

    Heleno Rodrigues Corrêa Filho

    2002-12-01

    Full Text Available OBJETIVO: Estimar as prevalências de perda auditiva induzida por ruído e hipertensão arterial em condutores de ônibus urbanos. MÉTODOS: Executou-se estudo transversal em amostra probabilística de 108 motoristas da cidade de Campinas, SP. Aplicou-se questionário sobre história profissional, jornadas de trabalho e repouso, e realizou-se exame físico e laboratorial incluindo medida da pressão arterial, audiometria tonal limiar, logoaudiometria e dados antropométricos, após a obtenção de consentimento. RESULTADOS: A prevalência de perda auditiva induzida por ruído foi de 32,7% do total examinado. Segundo a classificação de Merluzzi, nos 31 casos classificados em primeiro e segundo graus, observou-se que a freqüência audiométrica com perda auditiva mais acentuada foi a de 6 kHz (61,3%, seguida pela de 4 kHz (38,7%, sem diferenças significantes quanto à lateralidade. A prevalência de hipertensão arterial diastólica (PAD³90 mmHG; PAS³140 mmHG foi de 13,2% dos examinados. CONCLUSÕES: O risco de disacusia induzida por ruído foi maior para os motoristas com mais de seis anos de trabalho, após ajuste para a perda relacionada com a idade, com um odds ratio de 19,25 (1,59OBJECTIVE: To estimate the prevalence of occupational noise-induced hearing loss and arterial hypertension among city bus drivers. METHODS: A cross-sectional study was carried out on a probability random sample of 108 city bus drivers taken out of a total of 1,529 estimated professionals in the city of Campinas, Brazil, in 1991. Drivers were interviewed using questionnaires on job history, shift work and vacation schedules and underwent clinical and laboratory examinations including measures of blood pressure, pure-tone audiometry, speech audiometry, and anthropometric data analysis after an informed consent was obtained. RESULTS: The prevalence of noise-induced hearing loss was 32.7%. According to Merluzzi's classification, 91.2% (31 cases were classified as

  3. [Greenhouse gas emissions, carbon leakage and net carbon sequestration from afforestation and forest management: A review.

    Science.gov (United States)

    Liu, Bo Jie; Lu, Fei; Wang, Xiao Ke; Liu, Wei Wei

    2017-02-01

    Forests play an important role in climate change mitigation and concentration of CO 2 reduction in the atmosphere. Forest management, especially afforestation and forest protection, could increase carbon stock of forests significantly. Carbon sequestration rate of afforestation ranges from 0.04 to 7.52 t C·hm -2 ·a -1 , while that of forest protection is 0.33-5.20 t C·hm -2 ·a -1 . At the same time, greenhouse gas (GHG) is generated within management boundary due to the production and transportation of the materials consumed in relevant activities of afforestation and forest management. In addition, carbon leakage is also generated outside boundary from activity shifting, market effects and change of environments induced by forest management. In this review, we summarized the definition of emission sources of GHG, monitoring methods, quantity and rate of greenhouse gas emissions within boundary of afforestation and forest management. In addition, types, monitoring methods and quantity of carbon leakage outside boundary of forest management were also analyzed. Based on the reviewed results of carbon sequestration, we introduced greenhouse gas emissions within boundary and carbon leakage, net carbon sequestration as well as the countervailing effects of greenhouse gas emissions and carbon leakage to carbon sequestration. Greenhouse gas emissions within management boundary counteract 0.01%-19.3% of carbon sequestration, and such counteraction could increase to as high as 95% considering carbon leakage. Afforestation and forest management have substantial net carbon sequestration benefits, when only taking direct greenhouse gas emissions within boundary and measurable carbon leakage from activity shifting into consideration. Compared with soil carbon sequestration measures in croplands, afforestation and forest management is more advantageous in net carbon sequestration and has better prospects for application in terms of net mitigation potential. Along with the

  4. Radiologic assessment of spinal CSF leakage in spontaneous intracranial hypotension

    International Nuclear Information System (INIS)

    Han, Chang Jin; Kim, Ji Hyung; Kim, Jang Sung; Kim, Sun Yong; Suh, Jung Ho

    1999-01-01

    To assess the usefulness of imaging modalities in the detection of spinal CSF leakage in spontaneous intracranial hypotension. Fifteen patients who complained of postural headache without any preceding cause showed typical brain MR findings of intracranial hypotension, including radiologically confirmed CSF leakage. All fifteen underwent brain MRI and radionuclide cisternography. CT myelography was performed in eight patients and spinal MRI in six. Medical records, imaging findings and the incidence of spinal CSF leakage during each modality were retrospectively reviewed. CSF leakage was most common at the cervicothoracic junction, where in seven of 15 cases it was seen on radionuclide cisternography as increased focal paraspinal activity. Leakage was noted at the mid-tho-racic level in three patients, at the upper thoracic level in two, and at the cervical and lumbar levels in the remaining two. In two patients multiple CSF leaks were noted, and in all, early radioactive accumulation in the bladder was visualized. CT myelography revealed extrathecal and paraspinal contrast leakage in three of eight patients, and among those who underwent spinal MRI, dural enhancement was observed at the site of CSF leakage in all six, abnormal CSF signal in the neural foramen in one, and epidural CSF collection in one. Radionuclide cisternography is a useful method for the detection of CSF leakage in spontaneous intracranial hypotension. CT myelography and spinal MRI help determine the precise location of leakage

  5. Particle and radiation leakage importance: definition, analysis, and interpretation

    International Nuclear Information System (INIS)

    Cacuci, D.G.; Wagschal, J.J.; Yaari, A.

    1982-01-01

    The concept of leakage importance function has been introduced and analyzed for physical systems governed by the Boltzmann transport equation. This leakage importance function represents a measure of the relative importance of source particles located at every point in phase space in contributing to the leakage and provides insight regarding the specific physical process that leads to leakage. The equation satisfied by the leakage importance function has been derived by using adjoint operators. It has been shown that procedures that are customarily used to derive an equation obeyed by an importance function suitable for an integral parameter such as a detector response or an eigenvalue lead to difficulties when directly applied to derive an equation obeyed by the leakage importance function. This is because, although leakage is also an integral parameter (i.e., a functional of the forward flux density), leakage is expressed in terms of a surface integral rather than in terms of volume integrals such as those appearing in expressions of detector responses or eigenvalues. Therefore, a procedure that departs from the customary course has been devised to derive the equation satisfied by the leakage importance function

  6. Introduction to audiology: Some basics about hearing loss, hearing technologies and barriers to hearing aid use

    DEFF Research Database (Denmark)

    Mourtou, Eleni; Meis, Markus

    2012-01-01

    This chapter provides background information for researchers who wish to become familiar with some basic medical and audiological aspects of hearing loss and the technology of hearing aids. It introduces (1) the disciplines involved in research on hearing loss, (2) the medical categories of hearing...... loss and their various effects on communication, (3) the different degrees of hearing loss as defined by different national and international organizations, (4) statistics on the preva- lence of hearing loss worldwide, (5) some technological aspects of hearing instruments, (6) sta- tistics on non...

  7. Image artifacts in concurrent transcranial magnetic stimulation (TMS) and fMRI caused by leakage currents: modeling and compensation.

    Science.gov (United States)

    Weiskopf, Nikolaus; Josephs, Oliver; Ruff, Christian C; Blankenburg, Felix; Featherstone, Eric; Thomas, Anthony; Bestmann, Sven; Driver, Jon; Deichmann, Ralf

    2009-05-01

    To characterize and eliminate a new type of image artifact in concurrent transcranial magnetic stimulation and functional MRI (TMS-fMRI) caused by small leakage currents originating from the high-voltage capacitors in the TMS stimulator system. The artifacts in echo-planar images (EPI) caused by leakage currents were characterized and quantified in numerical simulations and phantom studies with different phantom-coil geometries. A relay-diode combination was devised and inserted in the TMS circuit that shorts the leakage current. Its effectiveness for artifact reduction was assessed in a phantom scan resembling a realistic TMS-fMRI experiment. The leakage-current-induced signal changes exhibited a multipolar spatial pattern and the maxima exceeded 1% at realistic coil-cortex distances. The relay-diode combination effectively reduced the artifact to a negligible level. The leakage-current artifacts potentially obscure effects of interest or lead to false-positives. Since the artifact depends on the experimental setup and design (eg, amplitude of the leakage current, coil orientation, paradigm, EPI parameters), we recommend its assessment for each experiment. The relay-diode combination can eliminate the artifacts if necessary.

  8. Image Artifacts in Concurrent Transcranial Magnetic Stimulation (TMS) and fMRI Caused by Leakage Currents: Modeling and Compensation

    Science.gov (United States)

    Weiskopf, Nikolaus; Josephs, Oliver; Ruff, Christian C; Blankenburg, Felix; Featherstone, Eric; Thomas, Anthony; Bestmann, Sven; Driver, Jon; Deichmann, Ralf

    2009-01-01

    Purpose To characterize and eliminate a new type of image artifact in concurrent transcranial magnetic stimulation and functional MRI (TMS-fMRI) caused by small leakage currents originating from the high-voltage capacitors in the TMS stimulator system. Materials and Methods The artifacts in echo-planar images (EPI) caused by leakage currents were characterized and quantified in numerical simulations and phantom studies with different phantom-coil geometries. A relay-diode combination was devised and inserted in the TMS circuit that shorts the leakage current. Its effectiveness for artifact reduction was assessed in a phantom scan resembling a realistic TMS-fMRI experiment. Results The leakage-current-induced signal changes exhibited a multipolar spatial pattern and the maxima exceeded 1% at realistic coil-cortex distances. The relay-diode combination effectively reduced the artifact to a negligible level. Conclusion The leakage-current artifacts potentially obscure effects of interest or lead to false-positives. Since the artifact depends on the experimental setup and design (eg, amplitude of the leakage current, coil orientation, paradigm, EPI parameters), we recommend its assessment for each experiment. The relay-diode combination can eliminate the artifacts if necessary. J. Magn. Reson. Imaging 2009;29:1211–1217. © 2009 Wiley-Liss, Inc. PMID:19388099

  9. [FEDERAL CLINICAL RECOMMENDATIONS IN DIAGNOSIS, TREATMENT AND PREVENTION OF HEARING LOSS DUE TO NOISE].

    Science.gov (United States)

    Adeninskaya, E E; Bukhtiarov, I V; Bushmanov, A Iu; Dayhes, N A; Denisov, E I; Izmerov, N F; Mazitova, N N; Pankova, V B; Preobrazhenskaya, E A; Prokopenko, L V; Simonova, N I; Tavartkiladze, G A; Fedina, I N

    2016-01-01

    Noise induced hearing loss is a slowly developing hearing impairment, caused by occupational exposure to excessive noise levels, constitutes a lesion of the auditory analyzer and clinically manifested as chronic bilateral sensorineural hearing loss. Currently, there is not a treatment that provide a cure of sensorineural hearing loss. Regular, individually tailored treatment should be directed to the pathogenic mechanisms and specific clinical symptoms of hearing loss, as well as the prevention of complications. We recommend using non-drug therapies that can improve blood flow in labyrinth, tissue and cellular metabolism.

  10. Radionuclide diagnosis of pulmonary capillary protein leakage

    International Nuclear Information System (INIS)

    Creutzig, H.; Sturm, J.A.; Schober, O.; Nerlich, M.L.; Kant, C.J.; Medizinische Hochschule Hannover

    1984-01-01

    Pulmonary extravascular albumin extra-vasation in patients with adult respiratory distress syndrome can be quantified with radionuclide techniques. While imaging procedures with a computerized gamma camera will allow reproducible ROIs, this will be the main limitation in nonimaging measurements with small scintillation probes. Repeated positioning by one operator results in a mean spatial variation of position of about 2 cm and a variation in count rate of 25%. For the estimation of PCPL the small probes must be positioned under scintigraphic control. Under these conditions the results of both techniques are identical. The upper limit of normal was estimated to be 1 x E-5/sec. The standard deviation abnormal measurements was about 10%. The pulmonary capillary protein leakage can be quantified by radionuclide techniques with good accuracy, using the combination of imaging and nonimaging techniques. (orig.) [de

  11. Fluid leakage near the percolation threshold

    Science.gov (United States)

    Dapp, Wolf B.; Müser, Martin H.

    2016-02-01

    Percolation is a concept widely used in many fields of research and refers to the propagation of substances through porous media (e.g., coffee filtering), or the behaviour of complex networks (e.g., spreading of diseases). Percolation theory asserts that most percolative processes are universal, that is, the emergent powerlaws only depend on the general, statistical features of the macroscopic system, but not on specific details of the random realisation. In contrast, our computer simulations of the leakage through a seal—applying common assumptions of elasticity, contact mechanics, and fluid dynamics—show that the critical behaviour (how the flow ceases near the sealing point) solely depends on the microscopic details of the last constriction. It appears fundamentally impossible to accurately predict from statistical properties of the surfaces alone how strongly we have to tighten a water tap to make it stop dripping and also how it starts dripping once we loosen it again.

  12. Anomaly detection using magnetic flux leakage technology

    Energy Technology Data Exchange (ETDEWEB)

    Rempel, Raymond G. [BJ Pipeline Inspection Services, Alberta (Canada)

    2005-07-01

    There are many aspects to properly assessing the integrity of a pipeline. In-line-Inspection (ILI) tools, in particular those that employ the advanced use of Magnetic Flux Leakage (MFL) technology, provide a valuable means of achieving required up-to-date knowledge of a pipeline. More prevalent use of High Resolution MFL In-Line-Inspection tools is growing the knowledge base that leads to more reliable and accurate identification of anomalies in a pipeline, thus, minimizing the need for expensive verification excavations. Accurate assessment of pipeline anomalies can improve the decision making process within an Integrity Management Program and excavation programs can then focus on required repairs instead of calibration or exploratory digs. Utilizing the information from an MFL ILI inspection is not only cost effective but, as well, can also prove to be an extremely valuable building block of a Pipeline Integrity Management Program. (author)

  13. Leakages and pressure relation: an experimental research

    Directory of Open Access Journals (Sweden)

    F. De Paola

    2012-11-01

    Full Text Available Leaks in water systems are presently a frequent and increasing event that involves cost increase and poor service, not compliant to quality standards and modern management criteria. The most recent data available in Italy, resumed into the report issued by Control Committee for Water Resources Use (CONVIRI, shows leakages with an average value of 37%. It is therefore important, for maintenance perspective, to investigate occurrence and evolution of water leaks and the analytical link between leaks Qp and network pressure P, for a reliable calibration of water networks quali-quantitative simulation models. The present work reports the first results of an experimental campaign started at Laboratory of Hydraulics of Department of Hydraulics, Geotechnical and Environmental Engineering of University of Naples Federico II in order to analyze the features of Qp(P relation, which are compared with other results issued in literature.

  14. Potential gonadal dose from leakage radiation?

    International Nuclear Information System (INIS)

    Nicholson, R.A.

    1995-01-01

    The author draws attention to the potential dangers of leakage radiation from mobile image intensifier units, and points out that during interventional urological procedures, radiation from below the urologist's knees may irradiate male gonads without being intercepted by protective aprons. Results are presented for a Shimatzu WHA mobile II, phantom doses being measured with an ionization chamber. Dose rates measured in the male gonad position were compared with rates at waist level behind a 0.35 mm lead equivalent shielding and dose rates at collar level outside the lead apron. Results are also presented of a study on the effect on gonad dose of a) adding 0.7 mm lead shielding to the tube housing and b) adding 0.7 mm lead and removing the spacer cone to reduce scatter. Results show that it is possible for gonad doses to be comparable with those assumed for the eyes, rather than the body. (Author)

  15. Acoustic emission generated by fluid leakage

    International Nuclear Information System (INIS)

    Kim, H.C.

    1987-01-01

    The noise generated by the leaking saturated steam and subcooled water form various sizes of hole has been measured as function of leak rate and stagnation pressure. Acoustic emission (proportinal to root mean sguare voltage) is shown to be proportional to the leak rate and stagnation pressure. A transition of acoustic emission power is observed at the stagnation pressure 0.185 MPa associated with the transition to the critical flow state. Substantially higher acoustic emission power generated by the subcooled water leakage is attributed to the flashing source involving the phase transformation and volume expansion. The relative amplitude of noise spectrum becomes more spiky as the leak rate and stagnation pressure increased. (Author)

  16. Living with Hearing Loss

    Science.gov (United States)

    ... version of this page please turn Javascript on. Nora Woodruff and her family, including dad Bob, have ... hearing, balance, smell, taste, voice, speech, and language. Nora Woodruff, daughter of ABC newsman Bob Woodruff and ...

  17. Hearing loss - infants

    Science.gov (United States)

    ... can allow many infants to develop normal language skills without delay. In infants born with hearing loss, ... therapy allow many children to develop normal language skills at the same age as their peers with ...

  18. Types of Hearing Aids

    Science.gov (United States)

    ... aids : Most parts are contained in a small plastic case that rests behind the ear; the case ... certain situations (for example, background noise and whistle reduction). They also have greater flexibility in hearing aid ...

  19. Buying a Hearing Aid

    Science.gov (United States)

    ... in price according to style, features, and local market prices. Price can range from hundreds of dollars to more than $2,500 for a programmable, digital hearing aid. Purchase price should not be the ...

  20. Hearing regulates Drosophila aggression.

    Science.gov (United States)

    Versteven, Marijke; Vanden Broeck, Lies; Geurten, Bart; Zwarts, Liesbeth; Decraecker, Lisse; Beelen, Melissa; Göpfert, Martin C; Heinrich, Ralf; Callaerts, Patrick

    2017-02-21

    Aggression is a universal social behavior important for the acquisition of food, mates, territory, and social status. Aggression in Drosophila is context-dependent and can thus be expected to involve inputs from multiple sensory modalities. Here, we use mechanical disruption and genetic approaches in Drosophila melanogaster to identify hearing as an important sensory modality in the context of intermale aggressive behavior. We demonstrate that neuronal silencing and targeted knockdown of hearing genes in the fly's auditory organ elicit abnormal aggression. Further, we show that exposure to courtship or aggression song has opposite effects on aggression. Our data define the importance of hearing in the control of Drosophila intermale aggression and open perspectives to decipher how hearing and other sensory modalities are integrated at the neural circuit level.

  1. Devices for hearing loss

    Science.gov (United States)

    ... the sounds you want to hear. Assistive listening devices bring certain sounds directly to your ears. This can ... a small room or on a stage. Other devices can bring the sound from your TV, radio, or music ...

  2. Regional Hearing Clerk

    Science.gov (United States)

    The Regional Hearing Clerk receives filings for proceedings under the Consolidated Rules of Practice Governing the Administrative Assessment of Civil Penalties and the Revocation/Termination or Suspension of Permits, 40 Code of Federal Regulations Part 22

  3. Genes and Hearing Loss

    Science.gov (United States)

    ... expressivity is seen in families transmitting autosomal dominant Waardenburg syndrome. Within the same family, some affected members may ... risk of having a child with hearing problems. Patient Health Home Copyright © 2018 American Academy of Otolaryngology– ...

  4. Headphone listening habits and hearing thresholds in swedish adolescents

    Directory of Open Access Journals (Sweden)

    Stephen E Widen

    2017-01-01

    Full Text Available Introduction: The aim of this study was to investigate self-reported hearing and portable music listening habits, measured hearing function and music exposure levels in Swedish adolescents. The study was divided into two parts. Materials and Methods: The first part included 280 adolescents, who were 17 years of age and focused on self-reported data on subjective hearing problems and listening habits regarding portable music players. From this group, 50 adolescents volunteered to participate in Part II of the study, which focused on audiological measurements and measured listening volume. Results: The results indicated that longer lifetime exposure in years and increased listening frequency were associated with poorer hearing thresholds and more self-reported hearing problems. A tendency was found for listening to louder volumes and poorer hearing thresholds. Women reported more subjective hearing problems compared with men but exhibited better hearing thresholds. In contrast, men reported more use of personal music devices, and they listen at higher volumes. Discussion: Additionally, the study shows that adolescents listening for ≥3 h at every occasion more likely had tinnitus. Those listening at ≥85 dB LAeq, FF and listening every day exhibited poorer mean hearing thresholds, reported more subjective hearing problems and listened more frequently in school and while sleeping. Conclusion: Although the vast majority listened at moderate sound levels and for shorter periods of time, the study also indicates that there is a subgroup (10% that listens between 90 and 100 dB for longer periods of time, even during sleep. This group might be at risk for developing future noise-induced hearing impairments.

  5. A study on leakage-flow-induced vibrations: Pt. 1

    International Nuclear Information System (INIS)

    Inada, F.; Hayama, S.

    1990-01-01

    The viscous fluid-dynamic forces and the moments acting on the walls of a one-dimensional, narrow, tapered passage when one wall is vibrating in coupled translational and rotational modes are analyzed, and fluid-dynamic mass, damping and stiffness matrices are determined. By this means the mechanism of instability generated from the flow through a narrow passage is examined. In the case of a single-degree-of-freedom translational or rotational system, only diagonal components of the fluid-dynamic matrices are estimated, and it is found that both negative fluid-dynamic damping caused by the phase delay due to the fluid inertia and negative fluid-dynamic stiffness can occur. In the case of a single-degree-of-freedom translational system, if the passage is divergent, both negative fluid-dynamic damping and fluid-dynamic stiffness can occur. In the case of a single-degree-of-freedom rotational system, the area increment ratio of the passage, at which negative fluid-dynamic damping and fluid-dynamic stiffness can occur, changes remarkably with the location of the pivot. In the case of a two-degree-of-freedom translational and rotational system, it is difficult to conclude directly from the fluid-dynamic matrices whether the fluid-dynamic forces stabilize the system or not. (author)

  6. Biomembrane Permeabilization: Statistics of Individual Leakage Events Harmonize the Interpretation of Vesicle Leakage.

    Science.gov (United States)

    Braun, Stefan; Pokorná, Šárka; Šachl, Radek; Hof, Martin; Heerklotz, Heiko; Hoernke, Maria

    2018-01-23

    The mode of action of membrane-active molecules, such as antimicrobial, anticancer, cell penetrating, and fusion peptides and their synthetic mimics, transfection agents, drug permeation enhancers, and biological signaling molecules (e.g., quorum sensing), involves either the general or local destabilization of the target membrane or the formation of defined, rather stable pores. Some effects aim at killing the cell, while others need to be limited in space and time to avoid serious damage. Biological tests reveal translocation of compounds and cell death but do not provide a detailed, mechanistic, and quantitative understanding of the modes of action and their molecular basis. Model membrane studies of membrane leakage have been used for decades to tackle this issue, but their interpretation in terms of biology has remained challenging and often quite limited. Here we compare two recent, powerful protocols to study model membrane leakage: the microscopic detection of dye influx into giant liposomes and time-correlated single photon counting experiments to characterize dye efflux from large unilamellar vesicles. A statistical treatment of both data sets does not only harmonize apparent discrepancies but also makes us aware of principal issues that have been confusing the interpretation of model membrane leakage data so far. Moreover, our study reveals a fundamental difference between nano- and microscale systems that needs to be taken into account when conclusions about microscale objects, such as cells, are drawn from nanoscale models.

  7. Leakage Inductance Calculation for Planar Transformers with a Magnetic Shunt

    DEFF Research Database (Denmark)

    Jun, Zhang; Ouyang, Ziwei; Duffy, M. C.

    2013-01-01

    The magnetic shunt is generally inserted in a planar transformer to increase the leakage inductance which can be utilized as the series inductor in resonant circuits such as the LLC resonant converter. This paper presents a calculation methodology for the leakage inductance of the transformer...

  8. Theory and Practice of a Leakage Resilient Masking Scheme

    DEFF Research Database (Denmark)

    Balasch, Josep; Faust, Sebastian; Gierlichs, Benedikt

    2012-01-01

    A recent trend in cryptography is to formally prove the leakage resilience of cryptographic implementations – that is, one formally shows that a scheme remains provably secure even in the presence of side channel leakage. Although many of the proposed schemes are secure in a surprisingly strong m...

  9. Contrast media for radiological examination in gastrointestinal tract leakage

    NARCIS (Netherlands)

    A.Z. Ginai (Abida)

    1987-01-01

    textabstractThe aim of this investigation has been to find a safe and suitable contrast medium for radiological evaluation of the gastrointestinal tract in cases where leakage outside the GIT can be suspected. Leakage outside the gastro-intestinal tract lumen can occur in many ways eg.,

  10. Leakage-Resilient Cryptography from the Inner-Product Extractor

    DEFF Research Database (Denmark)

    Dziembowski, Stefan; Faust, Sebastian

    2011-01-01

    We present a generic method to secure various widely-used cryptosystems against arbitrary side-channel leakage, as long as the leakage adheres three restrictions: first, it is bounded per observation but in total can be arbitrary large. Second, memory parts leak independently, and, third, the ran...

  11. Anastomotic leakage after anterior resection for rectal cancer

    DEFF Research Database (Denmark)

    Bulow, S.

    2008-01-01

    On the basis of the literature about anastomotic leakage after anterior resection for rectal cancer a review is presented of the frequency, potential risk factors and consequences of leakage. The risk factors are evaluated according to the level of scientific evidence of the individual background...

  12. On the scaling of gas leakage from static seals

    International Nuclear Information System (INIS)

    Chivers, T.C.; Hunt, R.P.

    1977-01-01

    The interaction between gas leakage from static seals and eight potential variables is discussed. From a consideration of the interaction of these various parameters and the mechanical design of the seal system the importance of correctly interpreting leakage data is demonstrated. Given a situation where model experiments are necessary, this document forms a basis for the definition and interpretation of a test programme. (author)

  13. A review on leakage rate tests for containment isolation systems

    International Nuclear Information System (INIS)

    Kim, In Goo; Kim, Hho Jung

    1992-01-01

    Wide experiences in operating containment isolation systems have been accumulated in Korea since 1978. Hence, it becomes necessary to review the operating data in order to confirm the integrity of containments with about 50 reactor-years of experience and to establish the future direction to the containment test program. The objectives of present work are to collect, consolidate and assess the leakage rate data, and then to find out dominant leakage paths and factors affecting integrated leakage rate test. General trends of overall leakage show that more careful surveillance during pre-operational test can reduce the containment leakage. Dominant leakage paths are found to be through air locks and large-sized valves, such as butterfly valves of purge lines, so that weighted surveillance and inspection on these dominant leakage paths can considerably reduce the containment leakage. The atmosphere stabilization are found to be the most important to obtain the reliable result. In order to get well stabilized atmosphere, temperature and flow rate of compressed air should be kept constant and it is preferable not to operate fan cooler during pressurizing the containment for test

  14. Hunting the unknown: White-box database leakage detection

    NARCIS (Netherlands)

    Costante, E.; Hartog, den J.I.; Petkovic, M.; Etalle, S.; Pechenizkiy, M.; Atluri, V.; Pernul, G.

    2014-01-01

    Data leakage causes significant losses and privacy breaches worldwide. In this paper we present a white-box data leakage detection system to spot anomalies in database transactions. We argue that our approach represents a major leap forward w.r.t. previous work because: i) it significantly decreases

  15. Determination of Unidentified Leakage Using a Kalman Smoother

    International Nuclear Information System (INIS)

    Jang, Soek Bo; Heo, Gyunyoung; Ra, Insik; Han, Jeonghyun; Lee, Seon Woo

    2008-01-01

    Since the safety significance of leaks from the RCS can widely vary depending on the source of the leak as well as the leak rate, the detection of the leakage is an important issue. The leakage is classified into 1) identified leakage which is defined as leakage into closed systems such as pump seal or valve packing leaks that can be captured, and 2) unidentified leakage which is all other leakage. The unidentified leakage is typically determined by the RCS inventory balance method which is based on NUREG-1107. Since the accuracy of leak rate calculation is dependent of the plant operating condition, the change in the RCS temperature, inventory, and the transient operating condition should be avoided during the measurement period. Nevertheless, the operation of the makeup of the borated water into the RCS and the diversion of the inventory to the outside of the RCS boundary makes it difficult to maintain the plant stable over an hour. Due to the large fluctuation of the calculated leak rate, it is sometimes hard to know the trend of the leakage as well as the instantaneous leak rate. Any fluctuation of operating conditions can results in unreliable leak rate. This study proposes a new way of determining the unidentified leak rate using a Kalman filter and smoother technique. The proposed algorithm enhances the accuracy of the leak rate calculation not only for the steady state operations but also for transients in a well timed manner

  16. Do You Need a Hearing Test?

    Science.gov (United States)

    ... hearing them? Yes No Do you have difficulty hearing or understanding co-workers, clients, or customers? Yes No Do you feel restricted or limited by a hearing problem? Yes No Do you have difficulty hearing ...

  17. Acoustic Trauma - Hearing Loss in Teenagers

    Science.gov (United States)

    ... I Can Hear It, It's Too Loud: Earbuds & Teen Hearing Loss Page Content ​Many parents will agree ... hearing loss." Recommended Hearing Screenings for Older Children & Teens Kids should be screened at three ages: 11- ...

  18. Hearing Aids: MedlinePlus Health Topic

    Science.gov (United States)

    ... for hearing loss (Medical Encyclopedia) Also in Spanish Topic Image MedlinePlus Email Updates Get Hearing Aids updates ... MEDICAL ENCYCLOPEDIA Devices for hearing loss Related Health Topics Cochlear Implants Hearing Disorders and Deafness National Institutes ...

  19. Occupational hearing loss of market mill workers in the city of Accra, Ghana.

    Science.gov (United States)

    Kitcher, Emmanuel D; Ocansey, Grace; Abaidoo, Benjamin; Atule, Alidu

    2014-01-01

    Noise induced hearing loss (NIHL) is an irreversible sensorineural hearing loss associated with exposure to high levels of excessive noise. Prevention measures are not well established in developing countries. This comparative cross sectional study aims to determine the prevalence of hearing loss in both a group of high risk workers and a control group and to assess their knowledge of the effects of noise on hearing health. A total of 101 market mill workers and 103 controls employed within markets in the city of Accra, Ghana, were evaluated using a structured questionnaire and pure tone audiometry. The questionnaire assessed factors including self-reported hearing loss, tinnitus, knowledge on the effects of noise on hearing health and the use of hearing protective devices. Pure tone audiometric testing was conducted for both mill workers and controls. Noise levels at the work premises of the mill workers and controls were measured. Symptoms of hearing loss were reported by 24 (23.76%) and 8 (7.7%) mill workers and controls respectively. Fifty-five (54.5%) and fifty-four (52.37%) mill workers and controls exhibited knowledge of the effects of noise on hearing health. Five (5.0%) mill workers used hearing protective devices. There was significant sensorineural hearing loss and the presence of a 4 kHz audiometric notch among mill workers when compared with controls for the mean thresholds of 2 kHz, 3 kHz and 4 kHz (P = 0. 001). The prevalence of hearing loss in the better hearing ears of the mill workers and controls was 24.8% and 4.8% respectively (P hearing loss, which may be characteristic of NIHL in the better hearing ears of the mill workers and controls was 24.8% and 4.8% respectively. The majority of mill workers did not use hearing protection.

  20. Occupational hearing loss of market mill workers in the city of Accra, Ghana

    Directory of Open Access Journals (Sweden)

    Emmanuel D Kitcher

    2014-01-01

    Full Text Available Noise induced hearing loss (NIHL is an irreversible sensorineural hearing loss associated with exposure to high levels of excessive noise. Prevention measures are not well established in developing countries. This comparative cross sectional study aims to determine the prevalence of hearing loss in both a group of high risk workers and a control group and to assess their knowledge of the effects of noise on hearing health. A total of 101 market mill workers and 103 controls employed within markets in the city of Accra, Ghana, were evaluated using a structured questionnaire and pure tone audiometry. The questionnaire assessed factors including self-reported hearing loss, tinnitus, knowledge on the effects of noise on hearing health and the use of hearing protective devices. Pure tone audiometric testing was conducted for both mill workers and controls. Noise levels at the work premises of the mill workers and controls were measured. Symptoms of hearing loss were reported by 24 (23.76% and 8 (7.7% mill workers and controls respectively. Fifty-five (54.5% and fifty-four (52.37% mill workers and controls exhibited knowledge of the effects of noise on hearing health. Five (5.0% mill workers used hearing protective devices. There was significant sensorineural hearing loss and the presence of a 4 kHz audiometric notch among mill workers when compared with controls for the mean thresholds of 2 kHz, 3 kHz and 4 kHz (P = 0. 001. The prevalence of hearing loss in the better hearing ears of the mill workers and controls was 24.8% and 4.8% respectively (P < 0.5. The prevalence of hearing loss, which may be characteristic of NIHL in the better hearing ears of the mill workers and controls was 24.8% and 4.8% respectively. The majority of mill workers did not use hearing protection.