WorldWideScience

Sample records for leak detection techniques

  1. Pipeline Leak Detection Techniques

    OpenAIRE

    Chis, Timur

    2009-01-01

    Leak detection systems range from simple, visual line walking and checking ones to complex arrangements of hard-ware and software. No one method is universally applicable and operating requirements dictate which method is the most cost effective. The aim of the paper is to review the basic techniques of leak detection that are currently in use. The advantages and disadvantages of each method are discussed and some indications of applicability are outlined.

  2. Pipeline Leak Detection Techniques

    Directory of Open Access Journals (Sweden)

    Timur Chis, Ph.D., Dipl.Eng.

    2007-01-01

    Full Text Available Leak detection systems range from simple, visual line walking and checking ones to complex arrangements of hard-ware and software. No one method is universally applicable and operating requirements dictate which method is the most cost effective. The aim of the paper is to review the basic techniques of leak detection that are currently in use. The advantages and disadvantages of each method are discussed and some indications of applicability are outlined.

  3. Buried pipeline leak-detection technique and instruments using radioactive tracers

    International Nuclear Information System (INIS)

    Zhou Shuxuan; Lu Qingqian; Tang Yonghua

    1987-01-01

    For detecting and locating leaks on buried pipelines, a leak-detection technique and related instruments have been developed. Some quantity of fluid mixed with a radioactive tracer is injected. After the pipeline is cleaned, a leak-detector is put into and moves along the pipline to monitor the leaked radioactivity and to record both the radioactive signal and the time signal on a magnetic tape. From the signal curves, it can be judged whether there are any leaks on the pipeline and, if any, where they are

  4. Leak detection : Principles and practice

    International Nuclear Information System (INIS)

    Rama Rao, V.V.K.

    1981-01-01

    Principles of leak detection are explained and various aspects of leak detection techniques and leak detectors are reviewed. The review covers: units for leaks and leak tightness, classification of leaks, timing of leak testing, designing for ease of leak testing of any job, methods of leak detection, their ranges of application and limitations, leak detectors, response time of leak test, minimum detectable concentration of search gas during leak tests, and validity of leak tests. Helium mass spectrometer type leak detector and technique are described in detail. Recent improvements in leak detectors and techniques, particularly mass spectrometer leak detectors using gases other than helium (e.g. hydrogen, argon) are also covered in the review. (M.G.B.)

  5. Leak detection and localization in a pipeline system by application of statistical analysis techniques

    International Nuclear Information System (INIS)

    Fukuda, Toshio; Mitsuoka, Toyokazu.

    1985-01-01

    The detection of leak in piping system is an important diagnostic technique for facilities to prevent accidents and to take maintenance measures, since the occurrence of leak lowers productivity and causes environmental destruction. As the first step, it is necessary to detect the occurrence of leak without delay, and as the second step, if the place of leak occurrence in piping system can be presumed, accident countermeasures become easy. The detection of leak by pressure is usually used for detecting large leak. But the method depending on pressure is simple and advantageous, therefore the extension of the detecting technique by pressure gradient method to the detection of smaller scale leak using statistical analysis techniques was examined for a pipeline in steady operation in this study. Since the flow in a pipe irregularly varies during pumping, statistical means is required for the detection of small leak by pressure. The index for detecting leak proposed in this paper is the difference of the pressure gradient at the both ends of a pipeline. The experimental results on water and air in nylon tubes are reported. (Kako, I.)

  6. Hollow-core fiber sensing technique for pipeline leak detection

    Science.gov (United States)

    Challener, W. A.; Kasten, Matthias A.; Karp, Jason; Choudhury, Niloy

    2018-02-01

    Recently there has been increased interest on the part of federal and state regulators to detect and quantify emissions of methane, an important greenhouse gas, from various parts of the oil and gas infrastructure including well pads and pipelines. Pressure and/or flow anomalies are typically used to detect leaks along natural gas pipelines, but are generally very insensitive and subject to false alarms. We have developed a system to detect and localize methane leaks along gas pipelines that is an order of magnitude more sensitive by combining tunable diode laser spectroscopy (TDLAS) with conventional sensor tube technology. This technique can potentially localize leaks along pipelines up to 100 km lengths with an accuracy of +/-50 m or less. A sensor tube buried along the pipeline with a gas-permeable membrane collects leaking gas during a soak period. The leak plume within the tube is then carried to the nearest sensor node along the tube in a purge cycle. The time-to-detection is used to determine leak location. Multiple sensor nodes are situated along the pipeline to minimize the time to detection, and each node is composed of a short segment of hollow core fiber (HCF) into which leaking gas is transported quickly through a small pressure differential. The HCF sensing node is spliced to standard telecom solid core fiber which transports the laser light for spectroscopy to a remote interrogator. The interrogator is multiplexed across the sensor nodes to minimize equipment cost and complexity.

  7. Autoregressive techniques for acoustic detection of in-sodium water leaks

    International Nuclear Information System (INIS)

    Hayashi, K.

    1997-01-01

    We have been applied a background signal whitening filter built by univariate autoregressive model to the estimation problem of the leak start time and duration. In the 1995 present benchmark stage, we evaluated the method using acoustic signals from real hydrogen or water/steam injection experiments. The results show that the signal processing technique using this filter can detect reliability the leak signals with a sufficient signal-to-noise ratio. Even if the sensor signal contains non-boiling or non-leak high-amplitude pulses, they can be classified by spectral information. Especially, the feature signal made from the time-frequency spectrum of the filtered signal is very sensitive and useful. (author). 8 refs, 14 figs, 6 tabs

  8. Acoustic leak detection in nuclear power plants

    International Nuclear Information System (INIS)

    McElroy, J.W.

    1986-01-01

    For several years now, utilities have been utilizing acoustic leak detection methods as an operating tool in their nuclear power stations. The purpose for using the leak detection system at the various stations vary from safety, ALARA, improved operations, preventive maintenance, or increased plant availability. This paper describes the various acoustic techniques and their application. The techniques are divided into three categories: specific component leakage, intersystem leakage, and pipe through-wall crack leakage. The paper addresses each category in terms of motivation to monitor, method of application and operation, and benefits to be gained. Current requirements are reviewed and analyzed with respect to the acoustic techniques. The paper shows how acoustic leak detection is one of the most effective leak detection tools available. 9 figures, 1 table

  9. Acoustic surveillance techniques for SGU leak monitoring

    International Nuclear Information System (INIS)

    McKnight, J.A.; Rowley, R.; Beesley, M.J.

    1990-01-01

    The paper presents a brief review of the acoustic techniques applicable to the detection of steam generator unit leaks that have been studied in the UK. Before discussion of the acoustic detection methods a reference representation of the required performance as developed in the UK is given. The conclusion is made that preliminary specification for the acoustic leak detection of sodium/water leaks in steam generating units suggests that it will be necessary to detect better than a leak rate of 3 g/s within a few seconds. 10 refs, 12 figs

  10. Acoustic emission technique for leak detection in an end shield of a pressurized heavy water reactor

    International Nuclear Information System (INIS)

    Kalyanasundaram, P.; Jayakumar, T.; Raj, B.

    1989-01-01

    This paper discusses the successful application of the Acoustic Emission Technique (AET) for detection and location of leak paths present on the inaccessible side of an end shield of a Pressurized Heavy Water Reactor (PHWR). The methodology was based on the fact that air and water leak AE signals have different characteristic features. Baseline data was generated from a sound end-shield of a PHWR for characterizing the background noise. A mock up end-shield system with saw cut leak paths was used to verify the validity of the methodology. It was found that air leak signals under pressurisation (as low as 3 psi) could be detected by frequency domain analysis. Signals due to air leaks from various locations of a defective end-shield were acquired and analysed. It was possible to detect and locate leak paths. Presence of detected leak paths were further confirmed by alternate test. (orig.)

  11. Developments in steam generator leak detection at Ontario Hydro

    Energy Technology Data Exchange (ETDEWEB)

    Maynard, K.J.; Singh, V.P. [Ontario Hydro Technologies, Toronto, Ontario (Canada)

    1998-07-01

    A method for locating small tube leaks in steam generators has been developed and implemented at Ontario Hydro. The technique utilizes both helium leak detection and moisture leak detection. The combination of these two methods allows tube leaks to be detected in any part of the tube bundle, including those submerged below water near the tubesheet. The estimated detection limits for the helium and moisture leak detection systems are 0.001 kg/hr and 0.05 kg/hr respectively, expressed as leak rates measured at typical boiler operating conditions. This technology is best utilized in situations where the leak rate under operating conditions is smaller than the practical limit for fluorescein dye techniques ({approx}2 kg/hour). Other novel techniques have been utilized to increase the reliability and speed of the boiler leak search process. These include the use of argon carrier gas to stabilize the buoyant helium gas in the boiler secondary. (author)

  12. Developments in steam generator leak detection at Ontario Hydro

    International Nuclear Information System (INIS)

    Maynard, K.J.; Singh, V.P.

    1998-01-01

    A method for locating small tube leaks in steam generators has been developed and implemented at Ontario Hydro. The technique utilizes both helium leak detection and moisture leak detection. The combination of these two methods allows tube leaks to be detected in any part of the tube bundle, including those submerged below water near the tubesheet. The estimated detection limits for the helium and moisture leak detection systems are 0.001 kg/hr and 0.05 kg/hr respectively, expressed as leak rates measured at typical boiler operating conditions. This technology is best utilized in situations where the leak rate under operating conditions is smaller than the practical limit for fluorescein dye techniques (∼2 kg/hour). Other novel techniques have been utilized to increase the reliability and speed of the boiler leak search process. These include the use of argon carrier gas to stabilize the buoyant helium gas in the boiler secondary. (author)

  13. Detection of steam leaks into sodium in fast reactor steam generators by acoustic techniques - An overview of Indian programme

    International Nuclear Information System (INIS)

    Prabhakar, R.; Vyjayanthi, R.K.; Kale, R.D.

    1990-01-01

    Realising the potential of acoustic leak detection technique, an experimental programme was initiated a few years back at Indira Gandhi Centre for Atomic Research (IGCAR) to develop this technique. The first phase of this programme consists of experiments to measure background noise characteristics on the steam generator modules of the 40 MW (thermal) Fast Breeder Test Reactor (FBTR) at Kalpakkam and experiments to establish leak noise characteristics with the help of a leak simulation set up. By subjecting the measured data from these experiments to signal analysis techniques, a criterion for acoustic leak detection for FBTR steam generator will be evolved. Second phase of this programme will be devoted to developing an acoustic leak detection system suitable for installation in the 500 MWe Prototype Fast Breeder Reactor (PFBR). This paper discusses the first phase of the experimental programme, results obtained from measurements carried out on FBTR steam generators and results obtained from leak simulation experiments. Acoustic leak detection system being considered for PFBR is also briefly described. 4 refs, 8 figs, 1 tab

  14. Leak rate measurements and detection systems

    International Nuclear Information System (INIS)

    Kupperman, D.; Shack, W.J.; Claytor, T.

    1983-10-01

    A research program is under way to evaluate and develop improve leak detection systems. The primary focus of the work has been on acoustic emission detection of leaks. Leaks from artificial flaws, laboratory-generated IGSCCs and thermal fatigue cracks, and field-induced intergranular stress corrosion cracks (IGSCCs) from reactor piping have been examined. The effects of pressure, temperature, and leak rate and geometry on the acoustic signature are under study. The use of cross-correlation techniques for leak location and pattern recognition and autocorrelation for source discrimination is also being considered

  15. Technique for detecting liquid metal leaks

    International Nuclear Information System (INIS)

    Bauerle, J.E.

    1979-01-01

    In a system employing flowing liquid metal as a heat transfer medium in contact with tubular members containing a working fluid, i.e., steam, liquid metal leaks through the wall of the tubular member are detected by dislodging the liquid metal compounds forming in the tubular member at the leak locations and subsequently transporting the dislodged compound in the form of an aerosol to a detector responsive to the liquid metal compound. In the application to a sodium cooled tubular member, the detector would consist of a sodium responsive device, such as a sodium ion detector

  16. Detection of Leaks in Water Distribution System using Non-Destructive Techniques

    Science.gov (United States)

    Aslam, H.; Kaur, M.; Sasi, S.; Mortula, Md M.; Yehia, S.; Ali, T.

    2018-05-01

    Water is scarce and needs to be conserved. A considerable amount of water which flows in the water distribution systems was found to be lost due to pipe leaks. Consequently, innovations in methods of pipe leakage detections for early recognition and repair of these leaks is vital to ensure minimum wastage of water in distribution systems. A major component of detection of pipe leaks is the ability to accurately locate the leak location in pipes through minimum invasion. Therefore, this paper studies the leak detection abilities of the three NDT’s: Ground Penetration Radar (GPR) and spectrometer and aims at determining whether these instruments are effective in identifying the leak. An experimental setup was constructed to simulate the underground conditions of water distribution systems. After analysing the experimental data, it was concluded that both the GPR and the spectrometer were effective in detecting leaks in the pipes. However, the results obtained from the spectrometer were not very differentiating in terms of observing the leaks in comparison to the results obtained from the GPR. In addition to this, it was concluded that both instruments could not be used if the water from the leaks had reached on the surface, resulting in surface ponding.

  17. Steam leak detection in advance reactors via acoustics method

    International Nuclear Information System (INIS)

    Singh, Raj Kumar; Rao, A. Rama

    2011-01-01

    Highlights: → Steam leak detection system is developed to detect any leak inside the reactor vault. → The technique uses leak noise frequency spectrum for leak detection. → Testing of system and method to locate the leak is also developed and discussed in present paper. - Abstract: Prediction of LOCA (loss of coolant activity) plays very important role in safety of nuclear reactor. Coolant is responsible for heat transfer from fuel bundles. Loss of coolant is an accidental situation which requires immediate shut down of reactor. Fall in system pressure during LOCA is the trip parameter used for initiating automatic reactor shut down. However, in primary heat transport system operating in two phase regimes, detection of small break LOCA is not simple. Due to very slow leak rates, time for the fall of pressure is significantly slow. From reactor safety point of view, it is extremely important to find reliable and effective alternative for detecting slow pressure drop in case of small break LOCA. One such technique is the acoustic signal caused by LOCA in small breaks. In boiling water reactors whose primary heat transport is to be driven by natural circulation, small break LOCA detection is important. For prompt action on post small break LOCA, steam leak detection system is developed to detect any leak inside the reactor vault. The detection technique is reliable and plays a very important role in ensuring safety of the reactor. Methodology developed for steam leak detection is discussed in present paper. The methods to locate the leak is also developed and discussed in present paper which is based on analysis of the signal.

  18. Fully automatic AI-based leak detection system

    Energy Technology Data Exchange (ETDEWEB)

    Tylman, Wojciech; Kolczynski, Jakub [Dept. of Microelectronics and Computer Science, Technical University of Lodz in Poland, ul. Wolczanska 221/223, Lodz (Poland); Anders, George J. [Kinectrics Inc., 800 Kipling Ave., Toronto, Ontario M8Z 6C4 (Canada)

    2010-09-15

    This paper presents a fully automatic system intended to detect leaks of dielectric fluid in underground high-pressure, fluid-filled (HPFF) cables. The system combines a number of artificial intelligence (AI) and data processing techniques to achieve high detection capabilities for various rates of leaks, including leaks as small as 15 l per hour. The system achieves this level of precision mainly thanks to a novel auto-tuning procedure, enabling learning of the Bayesian network - the decision-making component of the system - using simulated leaks of various rates. Significant new developments extending the capabilities of the original leak detection system described in and form the basis of this paper. Tests conducted on the real-life HPFF cable system in New York City are also discussed. (author)

  19. LMFBR steam generator leak detection development in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Magee, P M; Gerrels, E E; Greene, D A [General Electric Company, Sunnyvale, CA (United States); McKee, J [Argonne National Laboratory, Argonne, IL (United States)

    1978-10-01

    Leak detection for Liquid Metal Fast Breeder Reactor steam generators is an important economic factor in the shutdown, repair and restart of a plant. Development of leak detection systems in the U.S. has concentrated on four areas: (1) chemical (H{sub 2} and O{sub 2}) leak detection meters; (2) acoustic leak detection/location techniques; (3) investigation of leak behavior (enlargement, damage effects, plugging and unplugging); and (4) data management for plant operations. This paper discusses the status, design aspects, and applications of leak detection technology for LMFBR plants. (author)

  20. LMFBR steam generator leak detection development in the United States

    International Nuclear Information System (INIS)

    Magee, P.M.; Gerrels, E.E.; Greene, D.A.; McKee, J.

    1978-01-01

    Leak detection for Liquid Metal Fast Breeder Reactor steam generators is an important economic factor in the shutdown, repair and restart of a plant. Development of leak detection systems in the U.S. has concentrated on four areas: (1) chemical (H 2 and O 2 ) leak detection meters; (2) acoustic leak detection/location techniques; (3) investigation of leak behavior (enlargement, damage effects, plugging and unplugging); and (4) data management for plant operations. This paper discusses the status, design aspects, and applications of leak detection technology for LMFBR plants. (author)

  1. Environmental risk comparisons with internal methods of UST leak detection

    International Nuclear Information System (INIS)

    Durgin, P.B.

    1993-01-01

    The past five years have seen a variety of advances in how leaks can be detected from within underground storage tanks. Any leak-detection approach employed within a storage tanks must be conducted at specific time intervals and meet certain leak-rate criteria according to federal and state regulations. Nevertheless, the potential environmental consequences of leak detection approaches differ widely. Internal, volumetric UST monitoring techniques have developed over time including: (1) inventory control with stick measurements, (2) precision tank testing, (3) automatic tank gauging (ATG), (4) statistical inventory reconciliation (SIR), and (5) statistical techniques with automatic tank gauging. An ATG focuses on the advantage of precise data but measured for only a brief period. On the other hand, stick data has less precision but when combined with SIR over extended periods it too can detect low leak rates. Graphs demonstrate the comparable amounts of fuel than can leak out of a tank before being detected by these techniques. The results indicate that annual tank testing has the greatest potential for large volumes of fuel leaking without detection while new statistical approaches with an ATG have the least potential. The environmental implications of the volumes of fuel leaked prior to detection are site specific. For example, if storage tank is surrounded by a high water table and in a sole-source aquifer even small leaks may cause problems. The user must also consider regulatory risks. The level of environmental and regulatory risk should influence selection of the UST leak detection method

  2. Leak rate models and leak detection

    International Nuclear Information System (INIS)

    1992-01-01

    Leak detection may be carried out by a number of detection systems, but selection of the systems must be carefully adapted to the fluid state and the location of the leak in the reactor coolant system. Computer programs for the calculation of leak rates contain different models to take into account the fluid state before its entrance into the crack, and they have to be verified by experiments; agreement between experiments and calculations is generally not satisfactory for very small leak rates resulting from narrow cracks or from a closing bending moment

  3. Ultrasensitive leak detection

    International Nuclear Information System (INIS)

    Winkelman, C.R.; Davidson, H.G.

    1978-01-01

    The objective of this investigation was to develop a method of detecting leaks to a sensitivity of 1.0 x 10 -13 std/cm 3 /s in vacuum devices and to develop a qualifiable standard leak to provide system calibration at this leak rate. The development work demonstrated that minimum detectable leak rates of 6.5 x 10 -14 std/cm 3 /s and 5.5 x 10 -15 std/cm 3 /s are possible for respective analog and digital measurement modes

  4. 40 CFR Table 6 to Subpart IIIii of... - Examples of Techniques for Equipment Problem Identification, Leak Detection and Mercury Vapor

    Science.gov (United States)

    2010-07-01

    ... Problem Identification, Leak Detection and Mercury Vapor 6 Table 6 to Subpart IIIII of Part 63 Protection... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII..., Leak Detection and Mercury Vapor As stated in Tables 1 and 2 of Subpart IIIII, examples of techniques...

  5. Leak detection of complex pipelines based on the filter diagonalization method: robust technique for eigenvalue assessment

    International Nuclear Information System (INIS)

    Lay-Ekuakille, Aimé; Pariset, Carlo; Trotta, Amerigo

    2010-01-01

    The FDM (filter diagonalization method), an interesting technique used in nuclear magnetic resonance data processing for tackling FFT (fast Fourier transform) limitations, can be used by considering pipelines, especially complex configurations, as a vascular apparatus with arteries, veins, capillaries, etc. Thrombosis, which might occur in humans, can be considered as a leakage for the complex pipeline, the human vascular apparatus. The choice of eigenvalues in FDM or in spectra-based techniques is a key issue in recovering the solution of the main equation (for FDM) or frequency domain transformation (for FFT) in order to determine the accuracy in detecting leaks in pipelines. This paper deals with the possibility of improving the leak detection accuracy of the FDM technique thanks to a robust algorithm by assessing the problem of eigenvalues, making it less experimental and more analytical using Tikhonov-based regularization techniques. The paper starts from the results of previous experimental procedures carried out by the authors

  6. Evaluation of advanced and current leak detection systems

    International Nuclear Information System (INIS)

    Kupperman, D.S.

    1988-01-01

    U.S. Nuclear Regulatory Commission Guide 1.45 recommends the use of at least three different detection methods in reactors to detect leakage. Monitoring of both sump-flow and airborne particulate radioactivity is mandatory. A third method can involve either monitoring of condensate flow rate from air coolers or monitoring of airborne gaseous radioactivity. Although the methods currently used for leak detection reflect the state of the art, other techniques may be developed and used. Since the recommendations of Regulatory Guide 1.45 are not mandatory, Licensee Event Report Compilations have been reviewed to help establish actual capabilities for leak detection. The review of event reports, which had previously covered the period of June 1985 to August 1986 has been extended, and now covers events to June 1987. The total number of significant events is now 83. These reports have provided documented, sometimes detailed, summaries of reactor leaks. They have helped establish the capabilities of existing systems to detect and locate leaks. Differences between PWRs and BWRs with regard to leak detection have now been analyzed. With regard to detection methods, the greatest differences between reactor types are as follows: (a) The sump pump is reported as the detection method more frequently in BWRs than in PWRs (64% vs. 35%). (b) The radiation monitor is reported as the detection method (excluding false alarms) more frequently in PWRs. Current efforts at Argonne National Laboratory (ANL) to evaluate advanced acoustic leak detection methods are directed toward the generation and analysis of acoustic data from large (0.5 to 10 gal/min) leaks and modification of the software of the GARD/ANL advanced acoustic leak detection system. In order to reach the goal of 10 gal/min leaks, the Steam Generator Test Facility at ANL has been modified to carry out the leak testing. Tests were carried out with water at 525 deg. F and 1100 psi leaking through a fatigue crack in a 4-in

  7. Reliability of leak detection systems in light water reactors

    International Nuclear Information System (INIS)

    Kupperman, D.S.

    1987-01-01

    US Nuclear Regulatory Commission Guide 1.45 recommends the use of at least three different detection methods in reactors to detect leakage. Monitoring of both sump-flow and airborne particulate radioactivity is recommended. A third method can involve either monitoring of condensate flow rate from air coolers or monitoring of airborne gaseous radioactivity. Although the methods currently used for leak detection reflect the state of the art, other techniques may be developed and used. Since the recommendations of Regulatory Guide 1.45 are not mandatory, the technical specifications for 74 operating plants have been reviewed to determine the types of leak detection methods employed. In addition, Licensee Event Report (LER) Compilations from June 1985 to June 1986 have been reviewed to help establish actual capabilities for detecting leaks and determining their source. Work at Argonne National Laboratory has demonstrated that improvements in leak detection, location, and sizing are possible with advanced acoustic leak detection technology

  8. Pipeline leak detection and location by on-line-correlation with a process computer

    International Nuclear Information System (INIS)

    Siebert, H.; Isermann, R.

    1977-01-01

    A method for leak detection using a correlation technique in pipelines is described. For leak detection and also for leak localisation and estimation of the leak flow recursive estimation algorithms are used. The efficiency of the methods is demonstrated with a process computer and a pipeline model operating on-line. It is shown that very small leaks can be detected. (orig.) [de

  9. Preliminary study of the use of radiotracers for leak detection in industrial applications

    International Nuclear Information System (INIS)

    Wetchagarun, S; Petchrak, A; Tippayakul, C

    2015-01-01

    One of the most widespread uses of radiotracers in the industrial applications is the leak detection of the systems. This technique can be applied, for example, to detect leak in heat exchangers or along buried industrial pipelines. The ability to perform online investigation is one of the most important advantages of the radiotracer technique over other non-radioactive leak detection methods. In this paper, a preliminary study of the leak detection using radiotracer in the laboratory scale was presented. Br-82 was selected for this work due to its chemical property, its suitable half-life and its on-site availability. The NH 4 Br in the form of aqueous solution was injected into the experimental system as the radiotracer. Three NaI detectors were placed along the pipelines to measure system flow rate and to detect the leakage from the piping system. The results obtained from the radiotracer technique were compared to those measured by other methods. It is found that the flow rate obtained from the radiotracer technique agreed well with the one obtained from the flow meter. The leak rate result, however, showed discrepancy between results obtained from two different measuring methods indicating further study on leak detection was required before applying this technique in the industrial system. (paper)

  10. Preliminary study of the use of radiotracers for leak detection in industrial applications

    Science.gov (United States)

    Wetchagarun, S.; Petchrak, A.; Tippayakul, C.

    2015-05-01

    One of the most widespread uses of radiotracers in the industrial applications is the leak detection of the systems. This technique can be applied, for example, to detect leak in heat exchangers or along buried industrial pipelines. The ability to perform online investigation is one of the most important advantages of the radiotracer technique over other non-radioactive leak detection methods. In this paper, a preliminary study of the leak detection using radiotracer in the laboratory scale was presented. Br-82 was selected for this work due to its chemical property, its suitable half-life and its on-site availability. The NH4Br in the form of aqueous solution was injected into the experimental system as the radiotracer. Three NaI detectors were placed along the pipelines to measure system flow rate and to detect the leakage from the piping system. The results obtained from the radiotracer technique were compared to those measured by other methods. It is found that the flow rate obtained from the radiotracer technique agreed well with the one obtained from the flow meter. The leak rate result, however, showed discrepancy between results obtained from two different measuring methods indicating further study on leak detection was required before applying this technique in the industrial system.

  11. Enhanced leak detection risk model development

    Energy Technology Data Exchange (ETDEWEB)

    Harron, Lorna; Barlow, Rick; Farquhar, Ted [Enbridge Pipelines Inc., Edmonton, Alberta (Canada)

    2010-07-01

    Increasing concerns and attention to pipeline safety have engaged pipeline companies and regulatory agencies to extend their approaches to pipeline integrity. The implementation of High Consequence Areas (HCAs) has especially had an impact on the development of integrity management protocols (IMPs) for pipelines. These IMPs can require that a risk based assessment of integrity issues be applied to specific HCA risk factors. This paper addresses the development of an operational risk assessment approach for pipeline leak detection requirements for HCAs. A detailed risk assessment algorithm that includes 25 risk variables and 28 consequence variables was developed for application to all HCA areas. This paper describes the consultative process that was used to workshop the development of this algorithm. Included in this description is how the process addressed various methods of leak detection across a wide variety of pipelines. The paper also looks at development challenges and future steps in applying operation risk assessment techniques to mainline leak detection risk management.

  12. Air Conditioning Compressor Air Leak Detection by Image Processing Techniques for Industrial Applications

    Directory of Open Access Journals (Sweden)

    Pookongchai Kritsada

    2015-01-01

    Full Text Available This paper presents method to detect air leakage of an air conditioning compressor using image processing techniques. Quality of air conditioning compressor should not have air leakage. To test an air conditioning compressor leak, air is pumped into a compressor and then submerged into the water tank. If air bubble occurs at surface of the air conditioning compressor, that leakage compressor must be returned for maintenance. In this work a new method to detect leakage and search leakage point with high accuracy, fast, and precise processes was proposed. In a preprocessing procedure to detect the air bubbles, threshold and median filter techniques have been used. Connected component labeling technique is used to detect the air bubbles while blob analysis is searching technique to analyze group of the air bubbles in sequential images. The experiments are tested with proposed algorithm to determine the leakage point of an air conditioning compressor. The location of the leakage point was presented as coordinated point. The results demonstrated that leakage point during process could be accurately detected. The estimation point had error less than 5% compared to the real leakage point.

  13. Local Leak Detection and Health Monitoring of Pressurized Tanks

    Science.gov (United States)

    Polzin, Kurt; Witherow, William; Korman, Valentin; Sinko, John; Hendrickson, Adam

    2011-01-01

    An optical gas-detection sensor safely monitors pressurized systems (such as cryogenic tanks) and distribution systems for leaks. This sensor system is a fiber-coupled, solid optical body interferometer that allows for the miniaturized sensing element of the device to be placed in the smallest of recesses, and measures a wide range of gas species and densities (leaks). The deflection of the fringe pattern is detected and recorded to yield the time-varying gas density in the gap. This technology can be used by manufacturers or storage facilities with toxic, hazardous, or explosive gases. The approach is to monitor the change in the index of refraction associated with low-level gas leaks into a vacuum environment. The completion of this work will provide NASA with an enabling capability to detect gas system leaks in space, and to verify that pressurized systems are in a safe (i.e. non-leaking) condition during manned docking and transit operations. By recording the output of the sensor, a time-history of the leak can be constructed to indicate its severity. Project risk is mitigated by having several interferometric geometries and detection techniques available, each potentially leveraging hardware and lessons learned to enhance detectability.

  14. Detection of Leaks in Water Mains Using Ground Penetrating Radar

    OpenAIRE

    Alaa Al Hawari; Mohammad Khader; Tarek Zayed; Osama Moselhi

    2016-01-01

    Ground Penetrating Radar (GPR) is one of the most effective electromagnetic techniques for non-destructive non-invasive subsurface features investigation. Water leak from pipelines is the most common undesirable reason of potable water losses. Rapid detection of such losses is going to enhance the use of the Water Distribution Networks (WDN) and decrease threatens associated with water mains leaks. In this study, GPR approach was developed to detect leaks by implementing an appropriate imagin...

  15. Leak detection on the DIII-D tokamak using helium entrainment techniques

    International Nuclear Information System (INIS)

    Brooks, N.H.; Baxi, C.; Anderson, P.

    1988-01-01

    The entrainment of helium in a viscous gas flow was utilized to compartmentalize, and then to pinpoint, a leak across the inner skin of the double-walled DIII-D vacuum vessel. Inaccessible from the outside, the leak connected the cooling channels in the wall interspace with the primary vacuum chamber. By entraining helium in the pressurized flow from the single-pass gas circulation system, well-defined portions of the wall were exposed to helium without disassembly of the poorly accessible cooling manifolds. Varying the helium injection point permitted the localization of the leak to a single 30 0 toroidal sector of the vessel. The exact location of the leak was found from inside the vessel by spraying helium on suspect regions, while sweeping the contents of the cooling channels to the foreline of a Varian Contraflow leak detector with a 0.1 Pa m 3 /s flow of nitrogen. Flow speed calculations were used to predict the response time to entrained helium of the actual leak detection setup

  16. The simulation of acoustic propagation within SG water leak detection system

    International Nuclear Information System (INIS)

    Suzuki, Takehiko; Shioyama, Tsutomu

    1996-01-01

    It is important to detect the leak sound signal in a steam generator tube. For this purpose, it is necessary to develop the detection system capable of detecting the leak sound signal buried in external noises. This leak sound signal is measured the acceleration on the wall of the steam generator. The authors used a simulation technique to investigate how the sound generated in a steam generator propagates out of the generator. The results obtained using the simulation technique clarify that the observed signal had many resonation frequency courses due to scattering from complex structures. Therefore, the information of the original signal is lost. However, if the acceleration value many points on the outer wall is detected, and cross-correlation are obtained from each coupled measurement point, it is possible to separate the direct wave from a source point from the scattering waves in a measurement signal. Using the cross-correlation value, the source point of the leak sound signal in a steam generator tube is determined by the synthetic aperture focusing technique

  17. Technical Reviews on the Radioisotope Application for Leak Detection in Reservoirs

    International Nuclear Information System (INIS)

    Kim, Jin Seop; Jung, Sung Hee; Kim, Jong Bum; Kim, Jae Ho

    2006-02-01

    The previous techniques on the detection of leaks from reservoirs are difficult to identify the leak points and leak pathways in reservoirs. Additionally the complexity and ambiguity of data analysis resulted from them can increase the failures of leak detection. While, The technique using radioisotope as a tracer is considered to be very promising. In the same context, systematic studies led by IAEA are being practiced by organizing the task force team. The detection technique using natural tracer can give information about the age of ground water and the interconnection between ground water and reservoir water and the seepage origin. On the other hand, the one using artificial tracer can identify the leak point in reservoirs directly, in which radioactive cloud migration method and radioactive tracer adsorption method are included. The former is using hydrophilic radioisotope tracer, and the latter adsorptive radioisotope tracer which is emitting gamma ray. The radiotracer are injected at a point of the reservoir near to the bottom. Afterwards, the migration of the radioactive tracer is followed by means of submerged scintillation detectors suspended from boats. Usually 131 I, 82 Br, 46 Sc, and 198 Au etc. can be used as tracer. The point reaching the maximum concentration of tracer corresponds to the leak point in reservoirs

  18. Technical Reviews on the Radioisotope Application for Leak Detection in Reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Seop; Jung, Sung Hee; Kim, Jong Bum; Kim, Jae Ho

    2006-02-15

    The previous techniques on the detection of leaks from reservoirs are difficult to identify the leak points and leak pathways in reservoirs. Additionally the complexity and ambiguity of data analysis resulted from them can increase the failures of leak detection. While, The technique using radioisotope as a tracer is considered to be very promising. In the same context, systematic studies led by IAEA are being practiced by organizing the task force team. The detection technique using natural tracer can give information about the age of ground water and the interconnection between ground water and reservoir water and the seepage origin. On the other hand, the one using artificial tracer can identify the leak point in reservoirs directly, in which radioactive cloud migration method and radioactive tracer adsorption method are included. The former is using hydrophilic radioisotope tracer, and the latter adsorptive radioisotope tracer which is emitting gamma ray. The radiotracer are injected at a point of the reservoir near to the bottom. Afterwards, the migration of the radioactive tracer is followed by means of submerged scintillation detectors suspended from boats. Usually {sup 131}I, {sup 82}Br, {sup 46}Sc, and {sup 198}Au etc. can be used as tracer. The point reaching the maximum concentration of tracer corresponds to the leak point in reservoirs.

  19. Nuclear fuel element leak detection system

    International Nuclear Information System (INIS)

    John, C.D. Jr.

    1978-01-01

    Disclosed is a leak detection system integral with a wall of a building used to fabricate nuclear fuel elements for detecting radiation leakage from the nuclear fuel elements as the fuel elements exit the building. The leak detecting system comprises a shielded compartment constructed to withstand environmental hazards extending into a similarly constructed building and having sealed doors on both ends along with leak detecting apparatus connected to the compartment. The leak detecting system provides a system for removing a nuclear fuel element from its fabrication building while testing for radiation leaks in the fuel element

  20. Detecting leaks in vacuum bags

    Science.gov (United States)

    Carlstrom, E. E.

    1980-01-01

    Small leaks in vacuum bag can be readily detected by eye, using simple chemical reaction: combination of ammonia and acetic acid vapors to produce cloudy white smoke. Technique has been successfully used to test seam integrity and to identify minute pinholes in vacuum bag used in assembly of ceramic-tile heat shield for Space Shuttle Orbiter.

  1. Aspects of leak detection

    Energy Technology Data Exchange (ETDEWEB)

    Chivers, T.C. [Berkeley Technology Centre, Glos (United Kingdom)

    1997-04-01

    A requirement of a Leak before Break safety case is that the leakage from the through wall crack be detected prior to any growth leading to unacceptable failure. This paper sets out to review some recent developments in this field. It does not set out to be a comprehensive guide to all of the methods available. The discussion concentrates on acoustic emission and how the techniques can be qualified and deployed on operational plant.

  2. Aspects of leak detection

    International Nuclear Information System (INIS)

    Chivers, T.C.

    1997-01-01

    A requirement of a Leak before Break safety case is that the leakage from the through wall crack be detected prior to any growth leading to unacceptable failure. This paper sets out to review some recent developments in this field. It does not set out to be a comprehensive guide to all of the methods available. The discussion concentrates on acoustic emission and how the techniques can be qualified and deployed on operational plant

  3. Leak detection and localization in natural and artificial dams using tracer techniques

    International Nuclear Information System (INIS)

    Molinari, J.

    1975-01-01

    Leak detection and localization procedures using often-unknown techniques of identification by natural or artificial tracers are reported. From the analysis of data supplied by natural tracers, or by artificial tracer methods which involve the direct observation of warning phenomena, it is possible to estimate the extent of the infiltrations, define their origin and under certain circumstances determine the main hydrodynamic flow parameters so that their development may be followed. The examples of application and interpretation were taken from the numerous studies carried out in this field by the CEA, where many original investigation methods have been employed [fr

  4. Reliability evaluation of the Savannah River reactor leak detection system

    International Nuclear Information System (INIS)

    Daugherty, W.L.; Sindelar, R.L.; Wallace, I.T.

    1991-01-01

    The Savannah River Reactors have been in operation since the mid-1950's. The primary degradation mode for the primary coolant loop piping is intergranular stress corrosion cracking. The leak-before-break (LBB) capability of the primary system piping has been demonstrated as part of an overall structural integrity evaluation. One element of the LBB analyses is a reliability evaluation of the leak detection system. The most sensitive element of the leak detection system is the airborne tritium monitors. The presence of small amounts of tritium in the heavy water coolant provide the basis for a very sensitive system of leak detection. The reliability of the tritium monitors to properly identify a crack leaking at a rate of either 50 or 300 lb/day (0.004 or 0.023 gpm, respectively) has been characterized. These leak rates correspond to action points for which specific operator actions are required. High reliability has been demonstrated using standard fault tree techniques. The probability of not detecting a leak within an assumed mission time of 24 hours is estimated to be approximately 5 x 10 -5 per demand. This result is obtained for both leak rates considered. The methodology and assumptions used to obtain this result are described in this paper. 3 refs., 1 fig., 1 tab

  5. Leak detection by vibrational diagnostic methods

    International Nuclear Information System (INIS)

    Siklossy, P.

    1983-01-01

    The possibilities and methods of leak detection due to mechanical failures in nuclear power plants are reviewed on the basis of the literature. Great importance is attributed to vibrational diagnostic methods for their adventageous characteristics which enable them to become final leak detecting methods. The problems of noise analysis, e.g. leak detection by impact sound measurements, probe characteristics, gain problems, probe selection, off-line analysis and correlation functions, types of leak noises etc. are summarized. Leak detection based on noise analysis can be installed additionally to power plants. Its maintenance and testing is simple. On the other hand, it requires special training and measuring methods. (Sz.J.)

  6. Leak detection method

    International Nuclear Information System (INIS)

    1978-01-01

    This invention provides a method for removing nuclear fuel elements from a fabrication building while at the same time testing the fuel elements for leaks without releasing contaminants from the fabrication building or from the fuel elements. The vacuum source used, leak detecting mechanism and fuel element fabrication building are specified to withstand environmental hazards. (UK)

  7. Design of on-line steam generator leak monitoring system based on Cherenkov counting technique

    International Nuclear Information System (INIS)

    Dileep, B.N.; D'Cruz, S.J.; Biju, P.; Jashi, K.B.; Prabhakaran, V.; Venkataramana, K.; Managanvi, S.S.

    2006-01-01

    The methodology developed by Nuclear Power Corporation of India Ltd. for identification of leaky Steam Generator (SG) by monitoring 134 I activity in the blow down water is a very high sensitive method. However, this technique can not be put into use as an on-line system. A new method of on-line detection of SG leak and identify the offending SG based on Cherenkov counting technique is explained in this paper. It identifies the leak by detecting Cherenkov radiation produced by the hard beta emitting radio nuclides escaped into feed water during leak in an operating reactor. A simulated system shows that a leak rate of 2 kg/h can be detected by the proposed system, while coolant 134 I activity is 3.7 MBq/l (100μCi/l). (author)

  8. Application of acoustic leak detection technology for the detection and location of leaks in light water reactors

    International Nuclear Information System (INIS)

    Kupperman, D.S.; Prine, D.; Mathieson, T.

    1988-10-01

    This report presents the results of a study to evaluate the adequacy of leak detection systems in light water reactors. The sources of numerous reported leaks and methods of detection have been documented. Research to advance the state of the art of acoustic leak detection is presented, and procedures for implementation are discussed. 14 refs., 70 figs., 10 tabs

  9. Automatic Leak Detection in Buried Plastic Pipes of Water Supply Networks by Means of Vibration Measurements

    Directory of Open Access Journals (Sweden)

    Alberto Martini

    2015-01-01

    Full Text Available The implementation of strategies for controlling water leaks is essential in order to reduce losses affecting distribution networks of drinking water. This paper focuses on leak detection by using vibration monitoring techniques. The long-term goal is the development of a system for automatic early detection of burst leaks in service pipes. An experimental campaign was started to measure vibrations transmitted along water pipes by real burst leaks occurring in actual water supply networks. The first experimental data were used for assessing the leak detection performance of a prototypal algorithm based on the calculation of the standard deviation of acceleration signals. The experimental campaign is here described and discussed. The proposed algorithm, enhanced by means of proper signal filtering techniques, was successfully tested on all monitored leaks, thus proving effective for leak detection purpose.

  10. Acoustic emission technique for characterisation of deformation, fatigue, fracture and phase transformation and for leak detection with high sensitivity- our experiences

    International Nuclear Information System (INIS)

    Jayakumar, T.; Mukhopadhyay, C.K.; Baldev Raj

    1996-01-01

    Acoustic emission technique has been used for studying tensile deformation, fracture behaviour, detection and assessment of fatigue crack growth and α-martensite phase transformation in austenitic alloys. A methodology for amplification of weak acoustic emission signals has been established. Acoustic emission technique with advanced spectral analysis has enabled detection with high sensitivity of minute leaks in noisy environments. (author)

  11. Pipeline leak detection using volatile tracers

    International Nuclear Information System (INIS)

    Thompson, G.M.; Golding, R.D.

    1993-01-01

    A method of leak detection for underground storage tanks and pipelines adds volatile tracers to the products in the tanks and analyzes the surrounding shallow soil gases for tracer vapors. This method has several advantages: the success of the test is not limited by the size and structural design of the vessels, tanks can be tested at any fill level without taking the tank out of service, the location of a leak along a pipeline is clearly marked by the location of the tracer, and liquid leaks as small as 0.2 liters per hour (lph) can be detected. A limitation is: the backfill material must have some degree of air permeability in the zone above the water table. Several field tests document the success achieved using this method. A tracer leak detection system was installed at Homestead AFB after several other testing methods failed to locate a leak at a valve pit location along approximately 4 kilometers of fuel transfer piping. The leak was detected to the side of the valve pit at a depth of approximately 2.5 meters below the ground surface. Another installation of Edwards AFB involved the collection of 415 soil gas samples along approximately 3,050 meters of 15.25-centimeter fiberglass pipeline. Fourteen separate leaks were detected

  12. Calibration of a leak detection spectrometer

    International Nuclear Information System (INIS)

    Geller, R.

    1958-01-01

    This paper describes a study of the possible methods for calibrating a leak detection spectrometer, and the estimation of outputs from the leaks is considered. With this in mind the question of sensitivity of leak detection is tackled on a very general level; first the sensitivity of the isolated instrument is determined, and then the sensitivity of an instrument connected to an installation where leaks may be suspected. Finally, practical solutions are proposed. (author) [fr

  13. A leak-detection instrument for long buried pipelines based on radioactive tracer measurements

    International Nuclear Information System (INIS)

    Lu Qingqian; Zhou Shuxuan; Tang Yonghua; Sun Xiaolei; Hu Xusheng; Li Deyi; Yin Liqiang

    1987-01-01

    The instrument introduced provides a means for leak detection of long buried pipelines based on the radioactive tracer technique. The principle, block diagram and performances for the instrument are described. The leak-detecting method and the determination of some related parameters are also presented. Leak-detection sensitivity of the instrument is 185 kBq (5 μCi). Accuracy for leak localization is within 2.5 m (per km). It is suitable for the buried light oil (gasoline, kerosene, diesel oil) and industrial water pipelines with a diameter of 15 or 20 cm. The detection length for a single operation reaches up to 50 km

  14. Leak detection systems for VVER units based on leak before break concept. PowerPoint presentation

    International Nuclear Information System (INIS)

    Matal, Oldrich

    2010-01-01

    To comply with international standards, independent leak monitoring systems should be installed based on the monitoring of different physical parameters capable of detecting any small leak within one hour from the start of the leak. Such leak detection systems are based mainly on acoustic emission monitoring, humidity monitoring and/or radiation monitoring. Advanced systems integrate the monitoring of different physical parameters into one integrated leak detection system. The Integrated Leak Detection System (ILDS) for NPP Metsamor is described. This system consists of three independent leak detection subsystems, viz. LEMOP (LEak MOnitoring of Pipelines) based on acoustic emission monitoring, HUMOS (HUmidity MOnitoring System) based on humidity monitoring, and RAMOS (RAdiation MOnitoring System) based on radiation monitoring). The Integrated Leak Detection System (ILDS) collects data from the three systems, performs data evaluation, data storage, generates alarms and provides a user interface for the whole system including all subsystems. An example of DiagAssist user interface in the ILDS system in the pictorial form. (P.A.)

  15. 49 CFR 195.444 - CPM leak detection.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false CPM leak detection. 195.444 Section 195.444... PIPELINE Operation and Maintenance § 195.444 CPM leak detection. Each computational pipeline monitoring (CPM) leak detection system installed on a hazardous liquid pipeline transporting liquid in single...

  16. Specialists meeting on leak detection and location in LMFBR steam generators. Summary report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1978-10-01

    The following topics covered at the meeting were: with leak detection and location methods and equipment, including concentration measurements, helium tests, and electromagnetic methods; acoustic leak detection and related equipment; techniques and experiences in ensuring and measuring steam generator tightness during manufacturing, installation and repair, tube inspection methods for periodic control and damage assessment following leaks, influence of these methods on design of steam generators for LMFBR type reactors.

  17. Specialists meeting on leak detection and location in LMFBR steam generators. Summary report

    International Nuclear Information System (INIS)

    1978-10-01

    The following topics covered at the meeting were: with leak detection and location methods and equipment, including concentration measurements, helium tests, and electromagnetic methods; acoustic leak detection and related equipment; techniques and experiences in ensuring and measuring steam generator tightness during manufacturing, installation and repair, tube inspection methods for periodic control and damage assessment following leaks, influence of these methods on design of steam generators for LMFBR type reactors

  18. 49 CFR 195.134 - CPM leak detection.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false CPM leak detection. 195.134 Section 195.134... PIPELINE Design Requirements § 195.134 CPM leak detection. This section applies to each hazardous liquid... computational pipeline monitoring (CPM) leak detection system and each replaced component of an existing CPM...

  19. Leak detection for underground storage tanks

    International Nuclear Information System (INIS)

    Durgin, P.B.; Young, T.M.

    1993-01-01

    This symposium was held in New Orleans, Louisiana on January 29, 1992. The purpose of this conference was to provide a forum for exchange of state-of-the-art information on leak detection for underground storage tanks that leaked fuel. A widespread concern was protection of groundwater supplies from these leaking tanks. In some cases, the papers report on research that was conducted two or three years ago but has never been adequately directed to the underground storage tank leak-detection audience. In other cases, the papers report on the latest leak-detection research. The symposium was divided into four sessions that were entitled: Internal Monitoring; External Monitoring; Regulations and Standards; and Site and Risk Evaluation. Individual papers have been cataloged separately for inclusion in the appropriate data bases

  20. Leak detection device for control rod drive and detection method therefor

    International Nuclear Information System (INIS)

    Imasaki, Yoshio.

    1997-01-01

    The present invention provides a detection device for leak of cooling water from a sealed axial portion of control rod drives (CRD) disposed in a BWR type reactor and a monitoring method therefor. Namely, the CRD transfers rotation at the sealed axial portion and elevates/lowers a piston to insert/withdraw control rod into/from the reactor core. High pressure water is injected upon occurrence of scram to urge the piston upwardly thereby rapidly inserting the control rods. Leak detection pipelines are laid from the sealed axial portion. A flow glass is connected to the leak detection pipelines. Then, cooling water leaked from the sealed axial portion flows in the leak detection pipelines and flows into the flow glass. The flow rate of cooling water leaked from the sealed axial portion of the CRD can thus be detected by monitoring the flow glass. In addition, a flowmeter is connected to the leak detection pipelines, or the flowmeter and the flow glass are connected, and a flowmeter is connected downstream. Then, the flow rate of the leaked cooling water can be detected automatically. (I.S.)

  1. Strontium and cesium radionuclide leak detection alternatives in a capsule storage pool

    International Nuclear Information System (INIS)

    Larson, D.E.; Crawford, T.W.; Joyce, S.M.

    1981-08-01

    A study was performed to assess radionuclide leak-detection systems for use in locating a capsule leaking strontium-90 or cesium-137 into a water-filled pool. Each storage pool contains about 35,000 L of water and up to 715 capsules, each of which contains up to 150 kCi strontium-90 or 80 kCi cesium-137. Potential systems assessed included instrumental chemical analyses, radionuclide detection, visual examination, and other nondestructive nuclear-fuel examination techniques. Factors considered in the assessment include: cost, simplicity of maintenance and operation, technology availability, reliability, remote operation, sensitivity, and ability to locate an individual leaking capsule in its storage location. The study concluded that an adaption of the spent nuclear-fuel examination technique of wet sipping be considered for adaption. In the suggested approoch, samples would be taken continuously from pool water adjacent to the capsule(s) being examined for remote radiation detection. In-place capsule isolation and subsequent water sampling would confirm that a capsule was leaking radionuclides. Additional studies are needed before implementing this option. Two other techniques that show promise are ultrasonic testing and eddy-current testing

  2. Basis UST leak detection systems

    International Nuclear Information System (INIS)

    Silveria, V.

    1992-01-01

    This paper reports that gasoline and other petroleum products are leaking from underground storage tanks (USTs) at an alarming rate, seeping into soil and groundwater. Buried pipes are an even greater culprit, accounting for most suspected and detected leaks according to Environmental Protection Agency (EPA) estimates. In response to this problem, the EPA issued regulations setting standards for preventing, detecting, reporting, and cleaning up leaks, as well as fiscal responsibility. However, federal regulations are only a minimum; some states have cracked down even harder Plant managers and engineers have a big job ahead of them. The EPA estimates that there are more than 75,000 fuel USTs at US industrial facilities. When considering leak detection systems, the person responsible for making the decision has five primary choices: inventory reconciliation combined with regular precision tightness tests; automatic tank gauging; groundwater monitoring; interstitial monitoring of double containment systems; and vapor monitoring

  3. Acoustic leak detection of LMFBR steam generator

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi; Yoshida, Kazuo

    1993-01-01

    The development of a water leak detector with short response time for LMFBR steam generators is required to prevent the failure propagation caused by the sodium-water reaction and to maintain structural safety in steam generators. The development of an acoustic leak detector assuring short response time has attracted. The purpose of this paper is to confirm the basic detection feasibility of the active acoustic leak detector, and to investigate the leak detection method by erasing the background noise by spectrum analysis of the passive acoustic leak detector. From a comparison of the leak detection sensitivity of the active and the passive method, the active method is not influenced remarkably by the background noise, and it has possibility to detect microleakage with short response time. We anticipate a practical application of the active method in the future. (author)

  4. Development of acoustic leak detection and localization methods for inlet piping of fugen nuclear power plant

    International Nuclear Information System (INIS)

    Shimanskiy, Sergey; Iijima, Takashi; Naoi, Yosuke

    2004-01-01

    The development work carried out on Fugen NPP is focused on detection of a small leakage on the reactor's inlet feeder pipes at an early stage by an acoustic leak detection method with usage of high-temperature resistant microphones. Specifically, the leak rate of 0.046m 3 /h has been chosen as a target detection capability for this system. A cross-correlation technique has been studied for leak detection under low signal-noise ratios. The study shows that the sound diffusion on piping causes distortion of leak signals that results in their low correlation. A leak-location estimator and multi-channel correlation value, associated with estimated leak position, have been employed to detect such low-correlated leak signals. A method based on cross-correlation of signal spectral components has been proposed to deal with non-stationary leak signals. Joint-Time-Frequency-Analysis has been applied to analyze such signals, whilst a Wavelet decomposition technique has been used to extract their short-term spectral fluctuations. Since the spectral components are less affected by signal distortion, they provide higher correlation value and can be applied for leak detection under lower signal-noise ratios. The possibility of detecting and locating a small leakage by the methods proposed has been demonstrated by a number of simulation tests conducted on the Fugen NPP site. (author)

  5. 75 FR 4134 - Pipeline Safety: Leak Detection on Hazardous Liquid Pipelines

    Science.gov (United States)

    2010-01-26

    ... safety study on pipeline Supervisory Control and Data Acquisition (SCADA) systems (NTSB/SS-05/02). The... indications of a leak on the SCADA interface was the impetus for this study. The NTSB examined 13 hazardous... pipelines, the line balance technique for leak detection can often be performed with manual calculations...

  6. SCTI chemical leak detection test plan

    International Nuclear Information System (INIS)

    1981-01-01

    Tests will be conducted on the CRBRP prototype steam generator at SCTI to determine the effects of steam generator geometry on the response of the CRBRP chemical leak detection system to small water-to-sodium leaks in various regions of the steam generator. Specifically, small injections of hydrogen gas (simulating water leaks) will be made near the two tubesheets, and the effective transport times to the main stream exit and vent line hydrogen meters will be measured. The magnitude and time characteristics of the meters' response will also be measured. This information will be used by the Small Leak Protection Base Program (SG027) for improved predictions of meter response times and leak detection sensitivity

  7. Leak detection in pipelines through spectral analysis of pressure signals

    Directory of Open Access Journals (Sweden)

    Souza A.L.

    2000-01-01

    Full Text Available The development and test of a technique for leak detection in pipelines is presented. The technique is based on the spectral analysis of pressure signals measured in pipeline sections where the formation of stationary waves is favoured, allowing leakage detection during the start/stop of pumps. Experimental tests were performed in a 1250 m long pipeline for various operational conditions of the pipeline (liquid flow rate and leakage configuration. Pressure transients were obtained by four transducers connected to a PC computer. The obtained results show that the spectral analysis of pressure transients, together with the knowledge of reflection points provide a simple and efficient way of identifying leaks during the start/stop of pumps in pipelines.

  8. A Correlated Active Acoustic Leak Detection in a SFR Steam Generator

    International Nuclear Information System (INIS)

    Kim, Tae Joon; Jeong, Ji Young; Kim, Jong Man; Kim, Byung Ho; Kim, Yong Il

    2009-01-01

    The methods of acoustic leak detection are active acoustic leak detection and passive acoustic leak detection. The methods for passive acoustic leak detection are already established, but because our goal is development of passive acoustic leak detection for detecting a leakage range of small and micro leak rates, it is difficult detecting a leak in steam generator using this developed passive acoustic leak detection. Thus the acoustic leak detection system is required to be able to detect wide range of water leaks. From this view point we need to develop an active acoustic leak detection technology to be able to detect intermediate leak rates

  9. Detection of primary coolant leaks in NPP

    International Nuclear Information System (INIS)

    Slavov, S.; Bakalov, I.; Vassilev, H.

    2001-01-01

    The thermo-hydraulic analyses of the SG box behaviour of Kozloduy NPP units 3 and 4 in case of small primary circuit leaks and during normal operation of the existing ventilation systems in order to determine the detectable leakages from the primary circuit by analysing different parameters used for the purposes of 'Leak before break' concept, performed by ENPRO Consult Ltd. are presented. The following methods for leak detection: measurement of relative air humidity in SG box (can be used for detection of leaks with flow rate 3.78 l/min within one hour at ambient parameters - temperature 40 0 - 60 0 C and relative humidity form 30% to 60%); measurement of water level in SG box sumps (can not be used for reliable detection of small primary circuit leakages with flow rate about 3.78 l/min); measurement of gaseous radioactivity in SG box( can be used as a general global indication for detection of small leakages from the primary circuit); measurement of condensate flow after the air coolers of P-1 venting system (can be used for primary circuit leak detection) are considered. For determination of the confinement behaviour, a model used with computer code MELCOR has been developed by ENPRO Consult Ltd. A brief summary based on the capabilities of the different methods of leak detection, from the point of view of the applicability of a particular method is given. For both Units 3 and 4 of Kozloduy NPP a qualified complex system for small leak detection is planned to be constructed. Such a system has to unite the following systems: acoustic system for leak detection 'ALUS'; system for control of the tightness of the main primary circuit pipelines by monitoring the local humidity; system for primary circuit leakage detection by measuring condensate run-off in collecting tank after ventilation system P-1 air coolers

  10. Leak detection on underground fuel oil transfer line using radio tracer iodine-131

    International Nuclear Information System (INIS)

    Wickramanayake, D.G.L.; Ranjith, H.L.A.

    1998-01-01

    Leak detection study was carried out on the fuel oil transfer line of the Ceylon Petroleum Corporation using 131 I tracer. The study was carried out to determine whether the technique developed can be used in the field and to monitor the condition of the pipeline. Radiation safety assessment was made prior to the test. The dynamic pressurization technique was used. Any detectable leak was not shown at the detecting sensitivity of 0.40 mm 2 under the test conditions. The method reported is considered to be successful and economically viable. (author)

  11. Leak detection and localization system through acoustics; Sistema de deteccao e localizacao de vazamentos por acustica

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, Julio [Aselco Automacao, Sao Paulo, SP (Brazil)

    2003-07-01

    Acoustic Leak Detection Systems (ALDS) are used on both liquid and gas pipelines as well as multi-phase flow pipelines to detect leaks quickly and provide a means of limiting product loss. The real-time acoustic signal is continuously compared against signature leak profiles for the particular operating and geometric conditions. These profiles were developed from a database established from over 20 years of experimental and field leak tests. This technique not only drastically reduces the false alarm rate, but also significantly improves the sensitivity and leak location accuracy. This system will also detect leaks with shut-in flow (zero flow rate in the pipeline). With the use of GPS (Global Positioning System) it not only improves leak location accuracy, but also allows for continuous leak detection during the loss of communications. (author)

  12. Development of New Technology for Leak Detection of a Buried Pipe

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, D. B.; Park, J. H.; Moon, S. S.; Han, S. W.; Kang, T.; Kim, H. J.

    2014-01-15

    The importance of the leak detection of a buried pipe in a power plant of Korea is being emphasized as the buried pipes of a power plant are more than 20 years old. The first objective of this work is to develop new technologies for leak detection of a buried pipe. The second objective is to design and fabricate a trial product of leakage detection system for buried pipe. To achieve these purposes, as a first step, literature survey of the leak detection methods and techniques has been performed. As an algorithm for enhancing the leak detection capability of newly developed leakage detection system, an algorithm for removing mechanical noise and reflected wave within the pipe has been developed, and its feasibility was verified by performing numerical simulations and experiments. The hardware for leakage detection system is designed as a portable type by considering the test environment of a power plant, where speedy leakage inspection and rapid movement/reinstallation of the inspection equipment is necessary. The software is designed to provide a user-friendly GUI(Graphic User Interface) environment, making the system setup and data display quick and easy. It is also designed to allow for a real time visualization of analysis results on a monitoring screen for an estimation of the leakage location. The feature of the developed leak detection system is that it equipped with noise rejection algorithms that can effectively enhance the leak detection capability in a noisy environment. Then, a trial product of the leakage detection system has been fabricated, and its functionality and capability were verified by field experiments. The experimental results demonstrated that even in a noisy environment, the developed system can provide more reliable means for estimating the leak location of the buried pipe. It is expected that the reliability of leakage point estimation can be enhanced when the developed leak detection system is applied to a leakage estimation problem

  13. Development of New Technology for Leak Detection of a Buried Pipe

    International Nuclear Information System (INIS)

    Yoon, D. B.; Park, J. H.; Moon, S. S.; Han, S. W.; Kang, T.; Kim, H. J.

    2014-01-01

    The importance of the leak detection of a buried pipe in a power plant of Korea is being emphasized as the buried pipes of a power plant are more than 20 years old. The first objective of this work is to develop new technologies for leak detection of a buried pipe. The second objective is to design and fabricate a trial product of leakage detection system for buried pipe. To achieve these purposes, as a first step, literature survey of the leak detection methods and techniques has been performed. As an algorithm for enhancing the leak detection capability of newly developed leakage detection system, an algorithm for removing mechanical noise and reflected wave within the pipe has been developed, and its feasibility was verified by performing numerical simulations and experiments. The hardware for leakage detection system is designed as a portable type by considering the test environment of a power plant, where speedy leakage inspection and rapid movement/reinstallation of the inspection equipment is necessary. The software is designed to provide a user-friendly GUI(Graphic User Interface) environment, making the system setup and data display quick and easy. It is also designed to allow for a real time visualization of analysis results on a monitoring screen for an estimation of the leakage location. The feature of the developed leak detection system is that it equipped with noise rejection algorithms that can effectively enhance the leak detection capability in a noisy environment. Then, a trial product of the leakage detection system has been fabricated, and its functionality and capability were verified by field experiments. The experimental results demonstrated that even in a noisy environment, the developed system can provide more reliable means for estimating the leak location of the buried pipe. It is expected that the reliability of leakage point estimation can be enhanced when the developed leak detection system is applied to a leakage estimation problem

  14. Transient leak detection in crude oil pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Beushausen, R.; Tornow, S.; Borchers, H. [Nord-West Oelleitung, Wilhelmshaven (Germany); Murphy, K.; Zhang, J. [Atmos International Ltd., Manchester (United Kingdom)

    2004-07-01

    Nord-West Oelleitung (NWO) operates 2 crude oil pipelines from Wilhemshaven to Koln and Hamburg respectively. German regulations for transporting flammable substances stipulate that 2 independent continuously working procedures be used to detect leaks. Leak detection pigs are used routinely to complement the surveillance system. This paper described the specific issues of transient leak detection in crude oil pipelines. It was noted that traditional methods have failed to detect leaks that occur immediately after pumps are turned on or off because the pressure wave generated by the transient dominates the pressure wave that results from the leak. Frequent operational changes in a pipeline are often accompanied by an increased number of false alarms and failure to detect leaks due to unsteady operations. NWO therefore decided to have the Atmos statistical pipeline leak detection (SPLD) system installed on their pipelines. The key to the SPLD system is the sequential probability ratio test. Comprehensive data validation is performed following reception of pipeline data from the supervisory control and data acquisition (SCADA) system. The validated data is then used to calculate the corrected flow imbalance, which is fed into the SPRT to determine if there is an increase in the flow imbalance. Pattern recognition is then used to distinguish a leak from operational changes. The SPLD is unique because it uses 3 computational pipeline monitoring methods simultaneously, namely modified volume balance, statistical analysis, and pressure and flow monitoring. The successful installation and testing of the SPLD in 2 crude oil pipelines was described along with the main difficulties associated with transient leaks. Field results were presented for both steady-state and transient conditions. 5 refs., 2 tabs., 16 figs.

  15. Dynamic pressure measures for long pipeline leak detection

    Energy Technology Data Exchange (ETDEWEB)

    Likun Wang; Hongchao Wang; Min Xiong; Bin Xu; Dongjie Tan; Hengzhang Zhou [PetroChina Pipeline Company, Langfang (China). R and D Center

    2009-07-01

    Pipeline leak detection method based on dynamic pressure is studied. The feature of dynamic pressure which is generated by the leakage of pipeline is analyzed. The dynamic pressure method is compared with the static pressure method for the advantages and disadvantages in pipeline leak detection. The dynamic pressure signal is suitable for pipeline leak detection for quick-change of pipeline internal pressure. Field tests show that the dynamic pressure method detects pipeline leak rapidly and precisely. (author)

  16. The benefits of SCADA integrated pipeline leak detection

    Energy Technology Data Exchange (ETDEWEB)

    Pichler, Ruprecht M.J. [Pichler Engineering GmbH, Munich (Germany)

    2003-07-01

    Software based leak detection and locating for pipelines based upon evaluation of hydraulic parameters is a widely used approach to online pipeline integrity monitoring. Typically, these software packages are installed in a stand-alone configuration with a narrow bandwidth interface to the pipeline SCADA system. However, the performance characteristics of the SCADA system and interface do have a substantial impact on the performance of the leak detection system. By a tight integration of leak detection software into the SCADA system, a source of false alarms typically experienced with leak detection systems can be eliminated, the overall performance of the leak detection system can be improved, and the project costs can be reduced. (author)

  17. Probabilistic pipe fracture evaluations for leak-rate-detection applications

    International Nuclear Information System (INIS)

    Rahman, S.; Ghadiali, N.; Paul, D.; Wilkowski, G.

    1995-04-01

    Regulatory Guide 1.45, open-quotes Reactor Coolant Pressure Boundary Leakage Detection Systems,close quotes was published by the U.S. Nuclear Regulatory Commission (NRC) in May 1973, and provides guidance on leak detection methods and system requirements for Light Water Reactors. Additionally, leak detection limits are specified in plant Technical Specifications and are different for Boiling Water Reactors (BWRs) and Pressurized Water Reactors (PWRs). These leak detection limits are also used in leak-before-break evaluations performed in accordance with Draft Standard Review Plan, Section 3.6.3, open-quotes Leak Before Break Evaluation Proceduresclose quotes where a margin of 10 on the leak detection limit is used in determining the crack size considered in subsequent fracture analyses. This study was requested by the NRC to: (1) evaluate the conditional failure probability for BWR and PWR piping for pipes that were leaking at the allowable leak detection limit, and (2) evaluate the margin of 10 to determine if it was unnecessarily large. A probabilistic approach was undertaken to conduct fracture evaluations of circumferentially cracked pipes for leak-rate-detection applications. Sixteen nuclear piping systems in BWR and PWR plants were analyzed to evaluate conditional failure probability and effects of crack-morphology variability on the current margins used in leak rate detection for leak-before-break

  18. Summary of PWR leak detection studies

    International Nuclear Information System (INIS)

    Cho, J.H.; Elia, F.A. Jr.

    1986-01-01

    Thermal-hydraulic analysis can be used to determine the location and magnitude of leaks inside and location of leaks outside a pressurized water reactor (PWR) containment as required by plant technical specifications. The major advantage of this detection method is that it minimizes radiation exposure of maintenance personnel because most of the leak detection process is performed from the control room outside containment. Plant-specific analyses are utilized to predict change in parameters such as local dew point temperature, relative humidity, dry bulb temperature, and flow rate to sump for various leak rates and enthalpies. These parameter responses are then programmed into the plant computer and instrumentation is provided for area monitoring. The actual inputs are continuously monitored and compared to the predicted plant responses to identify the leak location and quantify the leak. This study concludes that a system that monitors dew point (or relative humidity) and dry bulb temperature changes together with the flow rate to the sump will provide the capability to both locate and quantify a leak inside a containment, while a system that monitors dew point temperature (or relative humidity) changes will provide the capability to locate a leak outside a containment

  19. Leak detection capability in CANDU reactors

    Energy Technology Data Exchange (ETDEWEB)

    Azer, N.; Barber, D.H.; Boucher, P.J. [and others

    1997-04-01

    This paper addresses the moisture leak detection capability of Ontario Hydro CANDU reactors which has been demonstrated by performing tests on the reactor. The tests confirmed the response of the annulus gas system (AGS) to the presence of moisture injected to simulate a pressure tube leak and also confirmed the dew point response assumed in leak before break assessments. The tests were performed on Bruce A Unit 4 by injecting known and controlled rates of heavy water vapor. To avoid condensation during test conditions, the amount of moisture which could be injected was small (2-3.5 g/hr). The test response demonstrated that the AGS is capable of detecting and annunciating small leaks. Thus confidence is provided that it would alarm for a growing pressure tube leak where the leak rate is expected to increase to kg/hr rapidly. The measured dew point response was close to that predicted by analysis.

  20. Leak detection capability in CANDU reactors

    International Nuclear Information System (INIS)

    Azer, N.; Barber, D.H.; Boucher, P.J.

    1997-01-01

    This paper addresses the moisture leak detection capability of Ontario Hydro CANDU reactors which has been demonstrated by performing tests on the reactor. The tests confirmed the response of the annulus gas system (AGS) to the presence of moisture injected to simulate a pressure tube leak and also confirmed the dew point response assumed in leak before break assessments. The tests were performed on Bruce A Unit 4 by injecting known and controlled rates of heavy water vapor. To avoid condensation during test conditions, the amount of moisture which could be injected was small (2-3.5 g/hr). The test response demonstrated that the AGS is capable of detecting and annunciating small leaks. Thus confidence is provided that it would alarm for a growing pressure tube leak where the leak rate is expected to increase to kg/hr rapidly. The measured dew point response was close to that predicted by analysis

  1. NON-DESTRUCTIVE LEAK DETECTION IN GALVANIZED IRON PIPE USING NONLINEAR ACOUSTIC MODULATION METHOD

    Directory of Open Access Journals (Sweden)

    Gigih Priyandoko

    2018-02-01

    Full Text Available Non-destructive testing is a wide group of analysis techniques used in science and industry to evaluate the properties of a structure without causing damage to it. The main objective of this project is to carry out experiment to detect leakage in pipeline using nonlinear acoustic modulation method. The nonlinear acoustic modulation approach with low frequency excitation and high frequency acoustic wave is used to reveal modulations in the presence of leak. The pipe used in this experiment was galvanized iron pipe. The experiment is started with the experiment of undamaged specimen and followed by the experiment of damaged specimen with manually applied leak. The results obtained are being observed and the difference between the specimen without leak and with leak can be distinguished. The distance of the leak and the distance of the outlet detected is nearly accurate to the exact location which is leak at 4.0 m and outlet at 6.0 m. Therefore, the results demonstrate that leakage can be detected using nonlinear acoustic modulation, and proved the objective of distinguish the difference between the results of specimen without leak and with leak has succeeded. The damage detection process can be eased with the knowledge on the signal features.

  2. Leak detection technologies for oil and gas pipelines; Tecnologias para deteccao e localizacao de vazamento em dutos de oleo e ou gas

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, Julio R. [MTT Aselco Automacao Ltda., Sao Paulo, SP (Brazil)

    2005-07-01

    Two concepts are available for leak detection in oil and/or gas pipelines: On-line leak detection system and off-line leak detection technique. The off-line leak detection technique is, usually, portable and does net configure a 'system'. This technique includes hydro-test, acoustic emission of high frequency, tracer of chemical substances, ultrasonic flow meter (UT), thermographic infra-red mapping, electromagnetic offset registration, etc. Since most of those methods requests stop of the system or depend on direct and detailed inspection of the whole monitored piping they are limited to the off-line inspection. In the current days there are only two technologies applied to detect and locate leaks on-line: The acoustic Leak Detection System and the modeling of computerized simulation also called as RTM (Real Time Modeling), RTTM or Mass Balance. There are still other techniques in the market, as acoustic emission, pressure analysis (PPA) beyond other rough techniques, without good results. Even some of these techniques are working without success, they are still used to accomplish with government standards. (author)

  3. Automatic Leak Detection in Buried Plastic Pipes of Water Supply Networks by Means of Vibration Measurements

    OpenAIRE

    Martini, Alberto; Troncossi, Marco; Rivola, Alessandro

    2015-01-01

    The implementation of strategies for controlling water leaks is essential in order to reduce losses affecting distribution networks of drinking water. This paper focuses on leak detection by using vibration monitoring techniques. The long-term goal is the development of a system for automatic early detection of burst leaks in service pipes. An experimental campaign was started to measure vibrations transmitted along water pipes by real burst leaks occurring in actual water supply networks. Th...

  4. Reliability of leak detection systems in LWRs

    International Nuclear Information System (INIS)

    Kupperman, D.S.

    1986-10-01

    In this paper, NRC guidelines for leak detection will be reviewed, current practices described, potential safety-related problems discussed, and potential improvements in leak detection technology (with emphasis on acoustic methods) evaluated

  5. Development of pressure boundaries leak detection technology for nuclear reactor

    International Nuclear Information System (INIS)

    Zhang Yao; Zhang Dafa; Chen Dengke; Zhang Liming

    2008-01-01

    The leak detection for the pressure boundaries is an important safeguard in nuclear reactor operation. In the paper, the status and the characters on the development of the pressure boundaries leak detection technology for the nuclear reactor were reviewed, especially, and the advance of the radiation leak detection technology and the acoustic emission leak detection technology were analyzed. The new advance trend of the leak detection technology was primarily explored. According to the analysis results, it is point out that the advancing target of the leak detection technology is to enhance its response speed, sensitivity, and reliability, and to provide effective information for operator and decision-maker. The realization of the global leak detection and the whole life cycle health monitoring for the nuclear boundaries is a significant advancing tendency of the leak detection technology. (authors)

  6. Acoustic leak detection and ultrasonic crack detection

    International Nuclear Information System (INIS)

    Kupperman, D.S.; Claytor, T.N.; Groenwald, R.

    1983-10-01

    A program is under way to assess the effectiveness of current and proposed techniques for acoustic leak detection (ALD) in reactor coolant systems. An ALD facility has been constructed and tests have begun on five laboratory-grown cracks (three fatigue and two thermal-fatigue and two field-induced IGSCC specimens. After ultrasonic testing revealed cracks in the Georgia Power Co. HATCH-1 BWR recirculation header, the utility installed an ALD system. Data from HATCH-1 have given an indication of the background noise level at a BWR recirculation header sweepolet weld. The HATCH leak detection system was tested to determine the sensitivity and dynamic range. Other background data have been acquired at the Watts Bar Nuclear Reactor in Tennessee. An ANL waveguide system, including transducer and electronics, was installed and tested on an accumulator safety injection pipe. The possibility of using ultrasonic wave scattering patterns to discriminate between IGSCCs and geometric reflectors has been explored. Thirteen reflectors (field IGSCCs, graphite wool IGSCCs, weld roots, and slits) were examined. Work with cast stainless steel (SS) included sound velocity and attenuation in isotropic and anisotropic cast SS. Reducing anisotropy does not help reduce attenuation in large-grained material. Large artificial flaws (e.g., a 1-cm-deep notch with a 4-cm path) could not be detected in isotropic centrifugally cast SS (1 to 2-mm grains) by longitudinal or shear waves at frequencies of 1 MHz or greater, but could be detected with 0.5-MHz shear waves. 13 figures

  7. Evaluation of methods for leak detection in reactor primary systems and NDE of cast stainless steel

    International Nuclear Information System (INIS)

    Kupperman, D.S.; Claytor, T.N.; Prine, D.W.; Mathieson, T.A.

    1984-01-01

    Six cracks, including two field-induced IGSCC specimens and two thermal-fatigue cracks, have been installed in a laboratory acoustic leak detection facility. The IGSCC specimens produce stronger acoustic signals than the thermal-fatigue cracks at equivalent leak rates. Despite significant differences in crack geometry, the acoustic signals from the two IGSCC specimens, tested at the same leak rate, are virtually identical in the frequency range from 200 to 400 kHz. Thus, the quantitative correlations between the acoustic signals and leak rate in the 300 to 400 kHz band are very similar for the two IGSCC specimens. Also, acoustic background data have been acquired during a hot functional sensitivity of acoustic leak detection techniques. In addition, cross-correlation techniques have been successfully used in the laboratory to locate the source of an electronically simulated leak signal

  8. Wireless sensor network for sodium leak detection

    International Nuclear Information System (INIS)

    Satya Murty, S.A.V.; Raj, Baldev; Sivalingam, Krishna M.; Ebenezer, Jemimah; Chandran, T.; Shanmugavel, M.; Rajan, K.K.

    2012-01-01

    Highlights: ► Early detection of sodium leak is mandatory in any reactor handling liquid sodium. ► Wireless sensor networking technology has been introduced for detecting sodium leak. ► We designed and developed a wireless sensor node in-house. ► We deployed a pilot wireless sensor network for handling nine sodium leak signals. - Abstract: To study the mechanical properties of Prototype Fast Breeder Reactor component materials under the influence of sodium, the IN Sodium Test (INSOT) facility has been erected and commissioned at Indira Gandhi Centre for Atomic Research. Sodium reacts violently with air/moisture leading to fire. Hence early detection of sodium leak if any is mandatory for such plants and almost 140 sodium leak detectors are placed throughout the loop. All these detectors are wired to the control room for data collection and monitoring. To reduce the cost, space and maintenance that are involved in cabling, the wireless sensor networking technology has been introduced in the sodium leak detection system of INSOT. This paper describes about the deployment details of the pilot wireless sensor network and the measures taken for the successful deployment.

  9. Evaluation of pipeline leak detection systems

    International Nuclear Information System (INIS)

    Glauz, W.D.; Flora, J.D.; Hennon, G.J.

    1993-01-01

    Leaking underground storage tank system presents an environmental concern and a potential health hazard. It is well known that leaks in the piping associated with these systems account for a sizeable fraction of the leaks. EPA has established performance standards for pipeline leak detection systems, and published a document presenting test protocols for evaluating these systems against the standards. This paper discusses a number of facets and important features of evaluating such systems, and presents results from tests of several systems. The importance of temperature differences between the ground and the product in the line is shown both in theory and with test data. The impact of the amount of soil moisture present is addressed, along with the effect of frozen soil. These features are addressed both for line tightness test systems, which must detect leaks of 0.10 gal/h (0.38 L/h) at 150% of normal line pressure, or 0.20 gal/h (0.76 L/h) at normal line pressure, and for automatic line leak detectors that must detect leaks of 3 gal/h (11 L/h) at 10 psi (69 kPa) within an hour of the occurrence of the leak. This paper also addresses some statistical aspects of the evaluation of these systems. Reasons for keeping the evaluation process ''blind'' to the evaluated company are given, along with methods for assuring that the tests are blind. Most importantly, a test procedure is presented for evaluating systems that report a flow rate (not just a pass/fail decision) that is much more efficient than the procedure presented in the EPA protocol, and is just as stringent

  10. Operational tank leak detection and minimization during retrieval

    International Nuclear Information System (INIS)

    Hertzel, J.S.

    1996-03-01

    This report evaluates the activities associated with the retrieval of wastes from the single-shell tanks proposed under the initial Single-Shell Tank Retrieval System. This report focuses on minimizing leakage during retrieval by using effective leak detection and mitigating actions. After reviewing the historical data available on single-shell leakage, and evaluating current leak detection technology, this report concludes that the only currently available leak detection method which can function within the most probable leakage range is the mass balance system. If utilized after each sluicing campaign, this method should allow detection at a leakage value well below the leakage value where significant health effects occur which is calculated for each tank. Furthermore, this report concludes that the planned sequence or sluicing activities will serve to further minimize the probability and volume of leaks by keeping liquid away from areas with the greatest potential for leaking. Finally, this report identifies a series of operational responses which when used in conjunction with the recommended sluicing sequence and leak detection methods will minimize worker exposure and environmental safety health risks

  11. A feasibility study on active ultrasonic techniques for water into sodium leak detection on FBR steam generator units

    International Nuclear Information System (INIS)

    Girard, J.P.; Garnaud, P.; Journeau, C.; Demarais, R.

    1990-01-01

    In the framework of the European Fast Breeder Project one of the aims is to provide the ferritic straight tube steam generator with a fast and reliable leak detection system. The first studies of water sodium leaks, based on the passive listening of noise source, are described. Considerable experience has been acquired of this technique and one of the conclusions is that a high level of reliability may require a sophisticated surveillance algorithm. Further works on the subject should lead to demonstration phase in 1993-1995 on a real and representative steam generator unit in order to have the benefit of a long term run of the surveillance method prior to industrial use in a compulsory safety system. 1 ref., 10 figs

  12. Detection and localization of leak of pipelines of RBMK reactor. Methods of processing of acoustic noise

    International Nuclear Information System (INIS)

    Tcherkaschov, Y.M.; Strelkov, B.P.; Chimanski, S.B.; Lebedev, V.I.; Belyanin, L.A.

    1997-01-01

    For realization of leak detection of input pipelines and output pipelines of RBMK reactor the method, based on detection and control of acoustic leak signals, was designed. In this report the review of methods of processing and analysis of acoustic noise is submitted. These methods were included in the software of the leak detection system and are used for the decision of the following problems: leak detection by method of sound pressure level in conditions of powerful background noise and strong attenuation of a signal; detection of a small leak in early stage by high-sensitivity correlation method; determination of a point of a sound source in conditions of strong reflection of a signal by a correlation method and sound pressure method; evaluation of leak size by the analysis of a sound level and point of a sound source. The work of considered techniques is illustrated on an example of test results of a fragment of the leak detection system. This test was executed on a Leningrad NPP, operated at power levels of 460, 700, 890 and 1000 MWe. 16 figs

  13. Small-target leak detection for a closed vessel via infrared image sequences

    Science.gov (United States)

    Zhao, Ling; Yang, Hongjiu

    2017-03-01

    This paper focus on a leak diagnosis and localization method based on infrared image sequences. Some problems on high probability of false warning and negative affect for marginal information are solved by leak detection. An experimental model is established for leak diagnosis and localization on infrared image sequences. The differential background prediction is presented to eliminate the negative affect of marginal information on test vessel based on a kernel regression method. A pipeline filter based on layering voting is designed to reduce probability of leak point false warning. A synthesize leak diagnosis and localization algorithm is proposed based on infrared image sequences. The effectiveness and potential are shown for developed techniques through experimental results.

  14. Leak detection evaluation of boiler tube for power plant using acoustic emission

    International Nuclear Information System (INIS)

    Lee, Sang Guk; Chung, Min Hwa; Nam, Ki Woo

    2001-01-01

    Main equipment of thermal power plant, such as boiler and turbine, are designed and manufactured by domestic techniques. And also the automatic control facilities controlling the main equipment are at the applying step of the localization. and many parts of BOP(Balance Of Plant) equipment are utilizing, localized. But because the special equipment monitoring the operation status of the main facilities such as boiler and turbine are still dependent upon foreign technology and especially boiler tube leak detection system is under the initial step of first application to newly-constructed plants and the manufacturing and application are done by foreign techniques mostly, fast localization development is required. Therefore, so as to study and develop boiler tube leak detection system, we performed studying on manufacturing, installation in site, acoustic emission(AE) signal analysis and discrimination etc. As a result of studying on boiler tube leak detection using AE, we conformed that diagnosis for boiler tube and computerized their trend management is possible, and also it is expected to contribute to safe operation of power generation facilities.

  15. The new CSA standard for leak detection

    Energy Technology Data Exchange (ETDEWEB)

    Pietsch, Ulli [TAU, Edmonton, Alberta, (Canada); Scott, Don [TransCanada Pipelines, Edmonton, Alberta, (Canada)

    2010-07-01

    Standards need to be updated regularly to reflect current technology and industry practices. This paper describes the new Canadian Standards Association (CSA) for leak detection called Recommended Practice for Liquid Hydrocarbon Pipeline System Leak Detection, Annex E, which can be found in the CSA Z662 Oil and Gas Pipeline Systems standard. The CSA formed a task force of industry experts and regulators for a period of 18 months to draft the new standards. Several comparisons were made with the American Petroleum Institute (API) recommended practice API 1130. This new version introduces and defines the terms, critical instrument, critical process and dependent instrument. The most significant improvement made by the new Annex E is the new requirement that an operating company must develop a leak detection strategy. The writing of a leak detection manual is given high priority. The use of both Annex E and API 1130 is recommended.

  16. Leak detection in a high-pressure heat exchanger system in a refinery using radiotracer technique

    International Nuclear Information System (INIS)

    Samantray, J.S.; Sunil Goswami; Sharma, V.K.; Jayashree Biswal; Pant, H.J.

    2014-01-01

    A radiotracer investigation was carried out in a diesel hydrotreater (DHDT) unit in a refinery for leak detection in a breech-lock heat exchanger system. The main objectives of the study were to identify the leaking heat exchanger in a system with six heat exchangers and estimate the leak rate. Bromine-82 as dibromobiphenyl was selected and used as radiotracer for the investigation. The radiotracer was instantaneously injected into the suction end of the feed pump line to the heat exchanger of the DHDT unit. The movement of the tracer was measured at strategically selected locations using NaI(Tl) scintillation detectors. Based upon the results of the radiotracer investigation, it was found that out of six heat exchangers, exchanger E-1F was leaking. (author)

  17. Leak Detection in Waterworks: Comparison Between STFT and FFT with an Overcoming of Limitations

    Directory of Open Access Journals (Sweden)

    Lay-Ekuakille Aimé

    2017-12-01

    Full Text Available Detection of leakages in pipelines is a matter of continuous research because of the basic importance for a waterworks system is finding the point of the pipeline where a leak is located and − in some cases − a nature of the leak. There are specific difficulties in finding leaks by using spectral analysis techniques like FFT (Fast Fourier Transform, STFT (Short Term Fourier Transform, etc. These difficulties arise especially in complicated pipeline configurations, e.g. a zigzag one. This research focuses on the results of a new algorithm based on FFT and comparing them with a developed STFT technique. Even if other techniques are used, they are costly and difficult to be managed. Moreover, a constraint in the leak detection is the pipeline diameter because it influences accuracy of the adopted algorithm. FFT and STFT are not fully adequate for complex configurations dealt with in this paper, since they produce ill-posed problems with an increasing uncertainty. Therefore, an improved Tikhonov technique has been implemented to reinforce FFT and STFT for complex configurations of pipelines. Hence, the proposed algorithm overcomes the aforementioned difficulties due to applying a linear algebraic approach.

  18. Leak detection using structure-borne noise

    Science.gov (United States)

    Holland, Stephen D. (Inventor); Chimenti, Dale E. (Inventor); Roberts, Ronald A. (Inventor)

    2010-01-01

    A method for detection and location of air leaks in a pressure vessel, such as a spacecraft, includes sensing structure-borne ultrasound waveforms associated with turbulence caused by a leak from a plurality of sensors and cross correlating the waveforms to determine existence and location of the leak. Different configurations of sensors and corresponding methods can be used. An apparatus for performing the methods is also provided.

  19. Hermetic Seal Leak Detection Apparatus

    Science.gov (United States)

    Kelley, Anthony R. (Inventor)

    2013-01-01

    The present invention is a hermetic seal leak detection apparatus, which can be used to test for hermetic seal leaks in instruments and containers. A vacuum tight chamber is created around the unit being tested to minimize gas space outside of the hermetic seal. A vacuum inducing device is then used to increase the gas chamber volume inside the device, so that a slight vacuum is pulled on the unit being tested. The pressure in the unit being tested will stabilize. If the stabilized pressure reads close to a known good seal calibration, there is not a leak in the seal. If the stabilized pressure reads closer to a known bad seal calibration value, there is a leak in the seal. The speed of the plunger can be varied and by evaluating the resulting pressure change rates and final values, the leak rate/size can be accurately calculated.

  20. Final evaluation of advanced and current leak detection systems

    International Nuclear Information System (INIS)

    Kupperman, D.S.; Carlson, R.; Brewer, W.; Lanham, R.

    1989-01-01

    This report presents the results of a study to evaluate the adequacy of leak detection systems in light water reactors. The sources of numerous reported leaks and methods of detection have been documented. Research to advance the state of the art of acoustic leak detection is presented, and procedures for implementation are discussed

  1. Intelligent leak detection system for oil pipelines; Sistema inteligente para deteccao de vazamentos em dutos de petroleo

    Energy Technology Data Exchange (ETDEWEB)

    Freitas, Ricardo Dantas Gadelha de [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil)

    2003-07-01

    One of the most challenging tasks in an oil field is implementation of a software-based leak detection system on a multi-phase flow pipeline. This paper will discuss implementation of a leak detection system in a particular oil field using state-of-the-art signal processing techniques to apply to the data collected in a oil pipeline. This leak detection system is still in development and uses a more practical approach to the problem than traditional methods and was implemented on a PC under the Windows operating system. Windowing, joint time-frequency analysis and wavelets were considered to develop methods of detecting leaks by watching for the wavefront. The idea behind these techniques is to cut the signal of interest into several parts and then analyze the parts separately. It is impossible to know the exact frequency and the exact time of occurrence of the leak frequency in a signal. In other words, a leak signal can simply not be represented as a point in the time-frequency space. It is very important how one cuts the signal to implement the analysis. The wavelet transform or wavelet analysis is probably the most recent solution to overcome the shortcomings of the Fourier transform. So, this paper shows some tests and how these techniques are being implementing during the development of the system. (author)

  2. Steam leak detection method in pipeline using histogram analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Se Oh; Jeon, Hyeong Seop; Son, Ki Sung; Chae, Gyung Sun [Saean Engineering Corp, Seoul (Korea, Republic of); Park, Jong Won [Dept. of Information Communications Engineering, Chungnam NationalUnversity, Daejeon (Korea, Republic of)

    2015-10-15

    Leak detection in a pipeline usually involves acoustic emission sensors such as contact type sensors. These contact type sensors pose difficulties for installation and cannot operate in areas having high temperature and radiation. Therefore, recently, many researchers have studied the leak detection phenomenon by using a camera. Leak detection by using a camera has the advantages of long distance monitoring and wide area surveillance. However, the conventional leak detection method by using difference images often mistakes the vibration of a structure for a leak. In this paper, we propose a method for steam leakage detection by using the moving average of difference images and histogram analysis. The proposed method can separate the leakage and the vibration of a structure. The working performance of the proposed method is verified by comparing with experimental results.

  3. Small sodium-to-gas leak behavior in relation to LMFBR leak detection system design

    International Nuclear Information System (INIS)

    Hopenfeld, J.; Taylor, G.R.; James, L.A.

    1976-01-01

    Various aspects of sodium-to-gas leaks which must be considered in the design of leak detection systems for LMFBR's are discussed. Attention is focused primarily on small, weeping type leaks. Corrosion rates of steels in fused sodium hydroxide and corrosion damage observed at the site of small leaks lead to the conclusion that the sodium-gas reaction products could attack the primary hot leg piping at rates up to 0.08 mils per hour. Based on theoretical considerations of the corrosion mechanism and on visual observations of pipe topography following small sodium leak tests, it is concluded that pipe damage will be manifested by the formation of small detectable leaks prior to the appearance of larger leaks. The case for uniform pipe corrosion along the pipe circumference or along a vertical section of the pipe is also examined. Using a theoretical model for the gravity flow of sodium and reaction products along the pipe surface and a mass transport controlled corrosion process, it is shown that below sodium leak rates of about 30 g/hr for the primary piping corrosion damage will not extend beyond one radius distance from the leak site. A method of estimating the time delay between the initiation of such leaks and the development of a larger leak due to increased pipe stresses resulting from corrosion is presented

  4. Ultrasonic leak detection

    International Nuclear Information System (INIS)

    Murphy, R.V.

    1977-01-01

    A scanning ultrasonic microphone was used to detect the presence and locate the sources of hydraulic noises in piping systems in a reactor environment. The intensity changes of the noises correspond to changes of flow conditions within the system caused by throttled valves, flow rate changes, and leaks. (author)

  5. The detection of leaks on sodium pipes in a 'leak before break' approach

    International Nuclear Information System (INIS)

    Antonakas, D.

    1989-01-01

    The operation of circuits containing liquid sodium requires, given the chemical affinity of this fluid for air and water, a reliable detection of possible leaks. This system of detection should alert the operators to the occurrence of a leak in sufficient time to limit the potential consequences of a discharge of sodium in the building, leading to a severe sodium fire or at least to an extended corrosion of the pipe system. From a design point of view, the most likely event leading to this situation can be the consequence. of an initial undetected defect which develops under the effect of thermo-mechanical loadings, produces a sodium. leak below the dejection threshold remains undetectable white progressing and finally leads to a guillotine-type rupture when an incidental loading is superimposed to the normal one. The 'leak before break' approach which is now currently introduced in design considerations consists of insuring the detection of incipient leaks corresponding to through-the-wall cracks well below instability of the pipe. Under this short statement, lies a considerable and still necessary effort of research broadly presented in the present paper

  6. An algorithm for leak point detection of underground pipelines

    International Nuclear Information System (INIS)

    Lee, Young Sup; Yoon, Dong Jin

    2004-01-01

    Leak noise is a good source to identify the exact location of a leak point of underground water pipelines. Water leak generates broadband noise from a leak location and can be propagated to both directions of water pipes. However, the necessity of long-range detection of this leak location makes to identify low-frequency acoustic waves rather than high frequency ones. Acoustic wave propagation coupled with surrounding boundaries including cast iron pipes is theoretically analyzed and the wave velocity was confirmed with experiment. The leak locations were identified both by the acoustic emission (AE) method and the cross-correlation method. In a short-range distance, both the AE method and cross-correlation method are effective to detect leak position. However, the detection for a long-range distance required a lower frequency range accelerometers only because higher frequency waves were attenuated very quickly with the increase of propagation paths. Two algorithms for the cross-correlation function were suggested, and a long-range detection has been achieved at real underground water pipelines longer than 300 m.

  7. Self-Detection of Leaking Pipes by One-Dimensional Photonic Crystals

    International Nuclear Information System (INIS)

    Zhou Yan; Yin Li-Qun

    2012-01-01

    We report a new self-detection control system for leaking pipes by making use of the surface defects of 1D photonic crystals, where the key concept is analog to the Bragg fiber structure. The current low costs and coating techniques of SiO 2 are beneficial to the applications, and its error is below the standard requirement. The problem of leaking pipes can be resolved by devising a remote pipeline control system which combines a long-distance pipeline and a signal transmission system. (fundamental areas of phenomenology(including applications))

  8. ISS Ammonia Leak Detection Through X-Ray Fluorescence

    Science.gov (United States)

    Camp, Jordan; Barthelmy, Scott; Skinner, Gerry

    2013-01-01

    Ammonia leaks are a significant concern for the International Space Station (ISS). The ISS has external transport lines that direct liquid ammonia to radiator panels where the ammonia is cooled and then brought back to thermal control units. These transport lines and radiator panels are subject to stress from micrometeorites and temperature variations, and have developed small leaks. The ISS can accommodate these leaks at their present rate, but if the rate increased by a factor of ten, it could potentially deplete the ammonia supply and impact the proper functioning of the ISS thermal control system, causing a serious safety risk. A proposed ISS astrophysics instrument, the Lobster X-Ray Monitor, can be used to detect and localize ISS ammonia leaks. Based on the optical design of the eye of its namesake crustacean, the Lobster detector gives simultaneously large field of view and good position resolution. The leak detection principle is that the nitrogen in the leaking ammonia will be ionized by X-rays from the Sun, and then emit its own characteristic Xray signal. The Lobster instrument, nominally facing zenith for its astrophysics observations, can be periodically pointed towards the ISS radiator panels and some sections of the transport lines to detect and localize the characteristic X-rays from the ammonia leaks. Another possibility is to use the ISS robot arm to grab the Lobster instrument and scan it across the transport lines and radiator panels. In this case the leak detection can be made more sensitive by including a focused 100-microampere electron beam to stimulate X-ray emission from the leaking nitrogen. Laboratory studies have shown that either approach can be used to locate ammonia leaks at the level of 0.1 kg/day, a threshold rate of concern for the ISS. The Lobster instrument uses two main components: (1) a microchannel plate optic (also known as a Lobster optic) that focuses the X-rays and directs them to the focal plane, and (2) a CCD (charge

  9. Laser-based sensor for a coolant leak detection in a nuclear reactor

    Science.gov (United States)

    Kim, T.-S.; Park, H.; Ko, K.; Lim, G.; Cha, Y.-H.; Han, J.; Jeong, D.-Y.

    2010-08-01

    Currently, the nuclear industry needs strongly a reliable detection system to continuously monitor a coolant leak during a normal operation of reactors for the ensurance of nuclear safety. In this work, we propose a new device for the coolant leak detection based on tunable diode laser spectroscopy (TDLS) by using a compact diode laser. For the feasibility experiment, we established an experimental setup consisted of a near-IR diode laser with a wavelength of about 1392 nm, a home-made multi-pass cell and a sample injection system. The feasibility test was performed for the detection of the heavy water (D2O) leaks which can happen in a pressurized heavy water reactor (PWHR). As a result, the device based on the TDLS is shown to be operated successfully in detecting a HDO molecule, which is generated from the leaked heavy water by an isotope exchange reaction between D2O and H2O. Additionally, it is suggested that the performance of the new device, such as sensitivity and stability, can be improved by adapting a cavity enhanced absorption spectroscopy and a compact DFB diode laser. We presume that this laser-based leak detector has several advantages over the conventional techniques currently employed in the nuclear power plant, such as radiation monitoring, humidity monitoring and FT-IR spectroscopy.

  10. Gas Leak Detection by Dilution of Atmospheric Oxygen

    Directory of Open Access Journals (Sweden)

    Armin Lambrecht

    2017-12-01

    Full Text Available Gas leak detection is an important issue in infrastructure monitoring and industrial production. In this context, infrared (IR absorption spectroscopy is a major measurement method. It can be applied in an extractive or remote detection scheme. Tunable laser spectroscopy (TLS instruments are able to detect CH4 leaks with column densities below 10 ppm·m from a distance of 30 m in less than a second. However, leak detection of non-IR absorbing gases such as N2 is not possible in this manner. Due to the fact that any leaking gas displaces or dilutes the surrounding background gas, an indirect detection is still possible. It is shown by sensitive TLS measurements of the ambient background concentration of O2 that N2 leaks can be localized with extractive and standoff methods for distances below 1 m. Minimum leak rates of 0.1 mbar·L/s were determined. Flow simulations confirm that the leakage gas typically effuses in a narrow jet. The sensitivity is mainly determined by ambient flow conditions. Compared to TLS detection of CH4 at 1651 nm, the indirect method using O2 at 761 nm is experimentally found to be less sensitive by a factor of 100. However, the well-established TLS of O2 may become a universal tool for rapid leakage screening of vessels that contain unknown or inexpensive gases, such as N2.

  11. Steam generator leak detection at Bruce A Unit 1

    International Nuclear Information System (INIS)

    Maynard, K.J.; McInnes, D.E.; Singh, V.P.

    1997-01-01

    A new steam generator leak detection system was recently developed and utilized at Bruce A. The equipment is based on standard helium leak detection, with the addition of moisture detection and several other capability improvements. All but 1% of the Unit 1 Boiler 03 tubesheet was inspected, using a sniffer probe which inspected tubes seven at a time and followed by individual tube inspections. The leak search period was completed in approximately 24 hours, following a prerequisite period of several days. No helium leak indications were found anywhere on the boiler. A single water leak indication was found, which was subsequently confirmed as a through-wall defect by eddy current inspection. (author)

  12. Vacuum leak test technique of JT-60

    International Nuclear Information System (INIS)

    Kaminaga, Atsushi; Arai, Takashi; Kodama, Kozo; Sasaki, Noboru; Saidoh, Masahiro

    1998-01-01

    Since a vacuum vessel of JT-60 is very large (167 m 3 ) and is combined with many components, such as magnetic coils, neutral beam injection systems and RF heating systems, etc., the position of leak testing exceeds 700. The two kind of techniques for vacuum leak test used in JT-60 has been described. Firstly the probe helium gas can be fed remotely in the three-dimensionally sectioned 54 regions of the JT-60 torus. The leak test was very rapidly performed by using this method. Secondly the helium detector system has been modified by the additional installation of the cryopump, which reduced the background level of the deuterium gas. The sensitivity of vacuum leak test with the cryopump was two orders of magnitude larger than that of without it. The examples of the performed vacuum leak test are stated. The vacuum leaks during experiments were 9 times. They were caused by thermal strain and plasma discharge. The vacuum leaks just after maintenance are 36 times which mainly caused by mis-installation. (author)

  13. Innovative Acoustic Sensor Technologies for Leak Detection in Challenging Pipe Types

    Science.gov (United States)

    2016-12-30

    the level of water leakage within the water distribution system. Table 7-3. Cost Summary for LeakFinderRT LeakFinderRT Leak Detection Cost...and to limit the drawdown of local water supplies. Implementation of improved leak detection technologies and the timely repair of water mains will...6-5. Water -filled Valve Box in Vicinity of Leak Detected by ZoneScan Alpha System

  14. Leak Detection Modeling and Simulation for Oil Pipeline with Artificial Intelligence Method

    OpenAIRE

    Sukarno, Pudjo; Sidarto, Kuntjoro Adji; Trisnobudi, Amoranto; Setyoadi, Delint Ira; Rohani, Nancy; Darmadi, Darmadi

    2007-01-01

    Leak detection is always interesting research topic, where leak location and leak rate are two pipeline leaking parameters that should be determined accurately to overcome pipe leaking problems. In this research those two parameters are investigated by developing transmission pipeline model and the leak detection model which is developed using Artificial Neural Network. The mathematical approach needs actual leak data to train the leak detection model, however such data could not be obtained ...

  15. Leak detection in LMFBR steam generators during operation

    International Nuclear Information System (INIS)

    Dumm, K.

    1978-01-01

    This paper deals with the following four main aspects: requirement on the leak detection of the SNR-300 steam generators; the hydrogen detector of SNR-300; remarks on the disadvantage of impurity detectors; and the first approach to acoustic leak detection systems

  16. Leak detection in LMFBR steam generators during operation

    Energy Technology Data Exchange (ETDEWEB)

    Dumm, K [INTERATOM, Bergisch Gladbach (Germany)

    1978-10-01

    This paper deals with the following four main aspects: requirement on the leak detection of the SNR-300 steam generators; the hydrogen detector of SNR-300; remarks on the disadvantage of impurity detectors; and the first approach to acoustic leak detection systems.

  17. Small leak detection requirements for SNR-300 steam generator operation

    International Nuclear Information System (INIS)

    Dumm, K.

    1975-01-01

    The leak detection philosophy of the SNR-300 steam generators is described. Due to operational demands small leaks have already to be detectable at a stage where secondary tube damage has not yet occurred. The requirements on a leak detection instrument are developed and the instrument itself is described. (author)

  18. Small leak detection requirements for SNR-300 steam generator operation

    Energy Technology Data Exchange (ETDEWEB)

    Dumm, K

    1975-07-01

    The leak detection philosophy of the SNR-300 steam generators is described. Due to operational demands small leaks have already to be detectable at a stage where secondary tube damage has not yet occurred. The requirements on a leak detection instrument are developed and the instrument itself is described. (author)

  19. Recent Progress in Technology of Leak detection

    Energy Technology Data Exchange (ETDEWEB)

    Jung, H. K.; Kim, S. H.; Cho, J. W.; Joo, Y. S.; Yang, D. J

    2005-07-15

    It is very important to check for leakage points of fluids and gases on primary pressure boundary of nuclear power plants in order to maintain and manage various structures safely. Even though much investigation has been performed by a number of researchers, there are a lot of problems to detect the leakage under some areas to which people can not approach. In particular, it is certainly necessary to find the leakage point in order to repair and replace the pressure boundaries. In this report, the basic principle and application situations for the development of the leak detection system which can detect micro-leaks are introduced. As the technologies and performances of recent sensors have been improving, the application range of leak detection has been increasing steadily. Therefore the sensor technologies written in this report will be able to contribute to nuclear safety to detect the leakage rate and the leakage point with an on-line monitoring system in the near future.

  20. Hydrogen detection systems leak response codes

    International Nuclear Information System (INIS)

    Desmas, T.; Kong, N.; Maupre, J.P.; Schindler, P.; Blanc, D.

    1990-01-01

    A loss in tightness of a water tube inside a Steam Generator Unit of a Fast Reactor is usually monitored by hydrogen detection systems. Such systems have demonstrated in the past their ability to detect a leak in a SGU. However, the increase in size of the SGU or the choice of ferritic material entails improvement of these systems in order to avoid secondary leak or to limit damages to the tube bundle. The R and D undertaken in France on this subject is presented. (author). 11 refs, 10 figs

  1. Least squares deconvolution for leak detection with a pseudo random binary sequence excitation

    Science.gov (United States)

    Nguyen, Si Tran Nguyen; Gong, Jinzhe; Lambert, Martin F.; Zecchin, Aaron C.; Simpson, Angus R.

    2018-01-01

    Leak detection and localisation is critical for water distribution system pipelines. This paper examines the use of the time-domain impulse response function (IRF) for leak detection and localisation in a pressurised water pipeline with a pseudo random binary sequence (PRBS) signal excitation. Compared to the conventional step wave generated using a single fast operation of a valve closure, a PRBS signal offers advantageous correlation properties, in that the signal has very low autocorrelation for lags different from zero and low cross correlation with other signals including noise and other interference. These properties result in a significant improvement in the IRF signal to noise ratio (SNR), leading to more accurate leak localisation. In this paper, the estimation of the system IRF is formulated as an optimisation problem in which the l2 norm of the IRF is minimised to suppress the impact of noise and interference sources. Both numerical and experimental data are used to verify the proposed technique. The resultant estimated IRF provides not only accurate leak location estimation, but also good sensitivity to small leak sizes due to the improved SNR.

  2. Fuel leak detection on large transport airplanes

    OpenAIRE

    Behbahani-Pour, M.J.; Radice, G.

    2016-01-01

    Fuel leakage has the risk of being ignited by external ignition sources, and therefore it is important to detect\\ud any fuel leakage before the departure of the aircraft. Currently, there are no fuel leak detection systems installed\\ud on commercial aircrafts, to detect fuel tank leakage, while only a small number of more recent aircraft, have a fuel\\ud monitoring system, that generates a fuel leak-warning message in cockpit in the case of fuel imbalance between the\\ud tanks. The approach pro...

  3. 1999 Leak Detection, Monitoring, and Mitigation Strategy Update

    International Nuclear Information System (INIS)

    OHL, P.C.

    1999-01-01

    This document is a complete revision of WHC-SD-WM-ES-378, Rev 1. This update includes recent developments in Leak Detection, Leak Monitoring, and Leak Mitigation technologies, as well as, recent developments in single-shell tank retrieval technologies. In addition, a single-shell tank retrieval release protection strategy is presented

  4. Capacitive system detects and locates fluid leaks

    Science.gov (United States)

    1966-01-01

    Electronic monitoring system automatically detects and locates minute leaks in seams of large fluid storage tanks and pipelines covered with thermal insulation. The system uses a capacitive tape-sensing element that is adhesively bonded over seams where fluid leaks are likely to occur.

  5. Leak detection in gas pipeline by acoustic and signal processing - A review

    Science.gov (United States)

    Adnan, N. F.; Ghazali, M. F.; Amin, M. M.; Hamat, A. M. A.

    2015-12-01

    The pipeline system is the most important part in media transport in order to deliver fluid to another station. The weak maintenance and poor safety will contribute to financial losses in term of fluid waste and environmental impacts. There are many classifications of techniques to make it easier to show their specific method and application. This paper's discussion about gas leak detection in pipeline system using acoustic method will be presented in this paper. The wave propagation in the pipeline is a key parameter in acoustic method when the leak occurs and the pressure balance of the pipe will generated by the friction between wall in the pipe. The signal processing is used to decompose the raw signal and show in time- frequency. Findings based on the acoustic method can be used for comparative study in the future. Acoustic signal and HHT is the best method to detect leak in gas pipelines. More experiments and simulation need to be carried out to get the fast result of leaking and estimation of their location.

  6. 75 FR 76742 - Detecting Oil Leaks From Vessels Into the Water

    Science.gov (United States)

    2010-12-09

    ... to detect leaks from oil tanks into the water? (E) What is the threshold for detection, accuracy... than leak detection from oil cargo tanks into the water? (H) Are methods or equipment being applied for... DEPARTMENT OF HOMELAND SECURITY Coast Guard [Docket No. USCG-2010-1085] Detecting Oil Leaks From...

  7. Sensors for Fluid Leak Detection

    Directory of Open Access Journals (Sweden)

    Gonzalo Pajares Martinsanz

    2015-02-01

    Full Text Available Fluid leak detection represents a problem that has attracted the interest of researchers, but not exclusively because in industries and services leaks are frequently common. Indeed, in water or gas supplies, chemical or thermal plants, sea-lines or cooling/heating systems leakage rates can cause important economic losses and sometimes, what it is more relevant, environmental pollution with human, animal or plant lives at risk. This last issue has led to increased national and international regulations with different degrees of severity regarding environmental conservation.[...

  8. Implementation of leak detection techniques in ducts with critical regimen multiphase flow; Implementacao de tecnicas de deteccao de vazamentos em dutos em regime de escoamento multifasico critico

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Rodrigo S.; Maitelli, Andr L.; Doria Neto, Adriao D.; Salazar, Andres O. [Rio Grande do Norte Univ., Natal, RN (Brazil)

    2005-07-01

    This paper presents signals processing techniques and artificial neural networks to identify leaks in multiphase flow pipeline. The greatest difficulty on traditional methods of leak detection (volume balance, pressure point analysis, etc) is that they are insufficient to design an adequate profile for the real conditions of oil pipeline transport. These difficult conditions goes since unevenly soil, that cause columns or vacuum throughout pipelines, until the presence of multi phases like water, gas and oil; plus other components as sand, which use to produce discontinuous flow off and diverse variations. To attenuate these difficulties, the transform wavelet was used to map the signal pressure in different resolution plan allowing the extraction of descriptors that identify leaks patterns and with then to provide training for the neural network multilayer perceptron (MLP) to learning of how to classify this pattern and report whenever this characterize leaks. During the tests were used transient and regime signals and pipelines with punctures with size variations from 1/2'' to 1'' of diameter to simulate leaks and, this way, it was possible to detect leaks with a time window of two minutes. The result show that the proposed descriptors considered, based in statistical methods applied in domain transform, are sufficient to identify leaks patterns and make it possible to train the neural classifier to indicate the occurrence of pipeline leaks. (author)

  9. Cable-Based Water Leak Detection Technology

    OpenAIRE

    ECT Team, Purdue

    2007-01-01

    Water leaks can be considered as a serious problem from many sources such as water supply and return chains, air conditioning units, cold-water chillers, clogged drains, damaged skylights or windows, or even construction errors. The new water leak detection technologies can provide significant advantages in cost, reliability, and easy adoption have continued since the traditional technology mainly focusing on a spot detector revealed several limitations.

  10. Novel Methods of Hydrogen Leak Detection

    International Nuclear Information System (INIS)

    Pushpinder S Puri

    2006-01-01

    For hydrogen to become a consumer fuel for automotive and domestic power generation, safety is paramount. Today's hydrogen systems are built with inherent safety measures and multiple levels of protection. However, human senses, in particular, the sense of smell, is considered the ultimate safeguards against leaks. Since hydrogen is an odorless gas, use of odorants to detect leaks, as is done in case of natural gas, is obvious solution. The odorants required for hydrogen used in fuel cells have a unique requirement which must be met. This is because almost all of the commercial odorants used in gas leak detection contain sulfur which acts as poison for the catalysts used in hydrogen based fuel cells, most specifically for the PEM (polymer electrolyte membrane or proton exchange membrane) fuel cells. A possible solution to this problem is to use non-sulfur containing odorants. Chemical compounds based on mixtures of acrylic acid and nitrogen compounds have been adopted to achieve a sulfur-free odorization of a gas. It is, therefore, desired to have a method and system for hydrogen leak detection using odorant which can incorporate a uniform concentration of odorant in the hydrogen gas, when odorants are mixed in the hydrogen storage or delivery means. It is also desired to develop methods where the odorant is not added to the bulk hydrogen, keeping it free of the odorization additives. A series of novel solutions are proposed which address the issues raised above. These solutions are divided into three categories as follows: 1. Methods incorporating an odorant in the path of hydrogen leak as opposed to adding it to the hydrogen gas. 2. Methods where odorants are generated in-situ by chemical reaction with the leaking hydrogen 3. Methods of dispensing and storing odorants in high pressure hydrogen gas which release odorants to the gas at a uniform and predetermined rates. Use of one or more of the methods described here in conjunction with appropriate engineering

  11. Study on Leak Detection of the Pipeline System by Acoustic Emission

    International Nuclear Information System (INIS)

    Yoon, D. J.; Kim, C. J.

    1987-01-01

    Leak detection testing for the pipeline system was performed by the acoustic emission method. It was found that the detected signal spectrum was influenced by the frequency response of sensors and pressure changes. AE parameters and frequency spectrum distributions were used to analyze the leak signals. The slope rise time of AE parameters were the important factors for distinguishing leak signals. The amplitude of leak signal was more affected by the changes of leak, rate and pressure than those of leak type

  12. Methods for detecting and locating leaks in containment facilities using electrical potential data and electrical resistance tomographic imaging techniques

    Science.gov (United States)

    Daily, William D.; Laine, Daren L.; Laine, Edwin F.

    1997-01-01

    Methods are provided for detecting and locating leaks in liners used as barriers in the construction of landfills, surface impoundments, water reservoirs, tanks, and the like. Electrodes are placed in the ground around the periphery of the facility, in the leak detection zone located between two liners if present, and/or within the containment facility. Electrical resistivity data is collected using these electrodes. This data is used to map the electrical resistivity distribution beneath the containment liner between two liners in a double-lined facility. In an alternative embodiment, an electrode placed within the lined facility is driven to an electrical potential with respect to another electrode placed at a distance from the lined facility (mise-a-la-masse). Voltage differences are then measured between various combinations of additional electrodes placed in the soil on the periphery of the facility, the leak detection zone, or within the facility. A leak of liquid though the liner material will result in an electrical potential distribution that can be measured at the electrodes. The leak position is located by determining the coordinates of an electrical current source pole that best fits the measured potentials with the constraints of the known or assumed resistivity distribution.

  13. Subsea leak detection systems - recommended practice

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Kristin Nergaard

    2010-07-01

    It is known in the industry that occasional leakages occur in subsea production systems. In spite of efforts to apply subsea leak detectors, the experience is that most leakages are either detected by ROV during routine inspections or interventions or as oil slicks on the surface . Operators and authority awareness towards the environmental impact of oil and gas production is increasing. The regulatory bodies in Norway, EU and USA specify requirements for detection of acute pollution. This paper presents the development of a Recommended Practice (RP) sponsored by OLF (The Norwegian Oil Industry Association). The JIP includes several major oil and gas operators. The objective of the RP is to serve as a technical and practical reference in the field of subsea leak detection. (Author)

  14. Commercial Grade Item (CGI) Dedication for Leak Detection Relays

    International Nuclear Information System (INIS)

    KOCH, M.R.; JOHNS, B.R.

    1999-01-01

    This Test Plan provides a test method to dedicate the leak detection relays used on the new Pumping and Instrumentation Control (PIC) skids. The new skids are fabricated on-site. The leak detection system is a safety class system per the Authorization Basis

  15. Current practice and developmental efforts for leak detection in US reactor primary systems

    International Nuclear Information System (INIS)

    Kupperman, D.S.; Claytor, T.N.

    1985-07-01

    Current leak detection practices in 74 operating nuclear reactors have been reviewed. Existing leak detection systems are adequate to ensure a leak-before-break scenario in most situations, but no currently available, single method combines optimal leakage detection sensitivity, leak-locating ability, and leakage measurement accuracy. Simply tightening current leakage limits may produce an unacceptably large number of unnecessary shutdowns. The use of commercially available acoustic monitoring systems or moisture-sensitive tape may improve leak detection capability at specific sites. However, neither of these methods currently provides source discrimination (e.g., to distinguish between leaks from pipe cracks and valves) or leak-rate information (a small leak may saturate the system). A field-implementable acoustic leak detection system is being developed to address these limitations. 5 refs., 3 figs

  16. Acoustic detection for water/steam leak from a tube of LMFBR steam generator

    International Nuclear Information System (INIS)

    Sonoda, Masataka; Shindo, Yoshihisa

    1989-01-01

    Acoustic leak detector is useful for detecting more quickly intermediate leak than the existing hydrogen detector and is available for identification of leak location on the accident of water/steam leak from a tube of LMFBR steam generator. This paper presents the overview of HALD (High frequency Acoustics Leak Detection) system, which is more sensitive for leak detection and lower cost of equipment for identification of leak location than a low frequency type detector. (author)

  17. Method and means of passive detection of leaks in buried pipes

    International Nuclear Information System (INIS)

    Claytor, T.N.

    1981-01-01

    A method and means for passive detection of a leak in a buried pipe containing fluid under pressure includes a plurality of acoustic detectors that are placed in contact with the pipe. Noise produced by the leak is detected by the detectors, and the detected signals are correlated to locate the leak. In one embodiment of the invention two detectors are placed at different locations to locate a leak between them. In an alternate embodiment two detectors of different waves are placed at substantially the same location to determine the distance of the leak from the location

  18. Detection of steam generator tube leaks in pressurized water reactors

    International Nuclear Information System (INIS)

    Roach, W.H.

    1985-01-01

    This report addresses the early detection of small steam generator tube leaks in pressurized water reactors. It discusses the third, and final, year's work on an NRC-funded project examining diagnostic instrumentation in water reactors. The first two years were broad in coverage, concentrating on anticipatory measurements for detection of potential problems in both pressurized- and boiling-water reactors, with recommendations for areas of further study. One of these areas, the early detection of small steam tube leaks in PWRs, formed the basis of study for the last year of the project. Four tasks are addressed in this study of the detection of steam tube leaks. (1) Determination of which physical parameters indicate the onset of steam generator tube leaks. (2) Establishing performance goals for diagnostic instruments which could be used for early detection of steam generator tube leaks. (3) Defining the diagnostic instrumentation and their location which satisfy Items 1 and 2 above. (4) Assessing the need for diagnostic data processing and display. Parameters are identified, performance goals established, and sensor types and locations are specified in the report, with emphasis on the use of existing instrumentation with a minimum of retrofitting. A simple algorithm is developed which yields the leak rate as a function of known or measurable quantities. The conclusion is that leak rates of less than one-tenth gram per second should be detectable with existing instrumentation. (orig./HP)

  19. On-line leak detection method for OWL-1 loop by ARX modeling using dewpoint signals

    International Nuclear Information System (INIS)

    Oguma, Ritsuo; Hayashi, Koji; Kitajima, Toshio.

    1981-01-01

    Model identification technique based on ARX (autoregressive model with exogenous variable) process was applied to dewpoint data recorded at OWL-1 (Oarai Water Loop No. 1) loop cubicle in JMTR (Japan Materials Testing Reactor) and the dynamical interrelationship between the supply and exhaust dewpoints in the ventilation system of the cubicle was empirically determined. It was shown that the information so derived on the dewpoint dynamics can assist to enhance the sensitivity of leak detection, if it was incorporated into a leak monitoring system for the OWL-1 loop. A simple digital filter incorporating the dewpoint dynamics was designed in an attempt to develop an efficient leak monitor for the OWL-1 loop. This filter was applied to the dewpoint data recordings during an abnormal leak that had occurred at the OWL-1 loop in the 43 rd cycle of JMTR operation, which demonstrated the effectiveness of the present method for leak detection at its early stage. (author)

  20. Liquid metal-to-gas leak-detection instruments

    International Nuclear Information System (INIS)

    Matlin, E.; Witherspoon, J.E.; Johnson, J.L.

    1982-01-01

    It is desirable for liquid-metal-cooled reactors that small liquid metal-to-gas leaks be reliably detected. Testing has been performed on a number of detection systems to evaluate their sensitivity, response time, and performance characteristics. This testing has been scheduled in three phases. The first phase was aimed at screening out the least suitable detectors and optimizing the performance of the most promising. In the second phase, candidates were tested in a 1500 ft 3 walk-in type enclosure in which leaks were simulated on 24-in. and 3-in. piping. In the third phase of testing, selected type detectors were tested in the 1500-ft 3 enclosure with Clinch River Breeder Reactor Plant (CRBRP) pipe insulation configurations and detector tubing configuration with cell gas recirculation simulated. Endurance testing of detection equipment was also performed as part of this effort. Test results have been shown that aerosol-type detectors will reliably detect leaks as small as a few grams per hour when sampling pipe insulation annuli

  1. Leak detection/verification

    Energy Technology Data Exchange (ETDEWEB)

    Krhounek, V.; Zdarek, J.; Pecinka, L. [Nuclear Research Institute, Rez (Czech Republic)

    1997-04-01

    Loss of coolant accident (LOCA) experiments performed as part of a Leak Before Break (LBB) analysis are very briefly summarized. The aim of these experiments was to postulate the leak rates of the coolant. Through-wall cracks were introduced into pipes by fatigue cycling and hydraulically loaded in a test device. Measurements included coolant pressure and temperature, quantity of leaked coolant, displacement of a specimen, and acoustic emission. Small cracks were plugged with particles in the coolant during testing. It is believed that plugging will have no effect in cracks with leak rates above 35 liters per minute. The leak rate safety margin of 10 is sufficient for cracks in which the leak rate is more than 5 liters per minute.

  2. Active acoustic leak detection for LMFBR steam generators. Pt. 7. Potential for small leak detection

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi; Yoshida, Kazuo

    1998-01-01

    In order to prevent the expansion of tube damage and to maintain structural integrity in the steam generators (SGs) of fast breeder reactors (FBR), it is necessary to detect precisely and immediately the leakage of water from heat transfer tubes. Therefore, an active acoustic method, which detects the sound attenuation due to bubbles generated in the sodium-water reactions, is being developed. Previous studies have revealed that the active acoustic method can detect bubbles of 10 l/s (equivalence water leak rate about 10 g/s) within 10 seconds in practical steam generators. In order to prevent the expansion of damage to neighboring tubes, however, it is necessary to detect smaller leakage of water from heat transfer tubes. In this study, in order to evaluate the detection sensitivity of the active method, the signal processing methods for emitter and receiver sound and the detection method for leakage within 1 g/s are investigated experimentally, using an SG full-sector model that simulates the actual SGs. A typical result shows that detection of 0.4 l/s air bubbles (equivalent water leak rate about 0.4 g/s) takes about 80 seconds, which is shorter than the propagation time of damage to neighboring tubes. (author)

  3. Infrared video based gas leak detection method using modified FAST features

    Science.gov (United States)

    Wang, Min; Hong, Hanyu; Huang, Likun

    2018-03-01

    In order to detect the invisible leaking gas that is usually dangerous and easily leads to fire or explosion in time, many new technologies have arisen in the recent years, among which the infrared video based gas leak detection is widely recognized as a viable tool. However, all the moving regions of a video frame can be detected as leaking gas regions by the existing infrared video based gas leak detection methods, without discriminating the property of each detected region, e.g., a walking person in a video frame may be also detected as gas by the current gas leak detection methods.To solve this problem, we propose a novel infrared video based gas leak detection method in this paper, which is able to effectively suppress strong motion disturbances.Firstly, the Gaussian mixture model(GMM) is used to establish the background model.Then due to the observation that the shapes of gas regions are different from most rigid moving objects, we modify the Features From Accelerated Segment Test (FAST) algorithm and use the modified FAST (mFAST) features to describe each connected component. In view of the fact that the statistical property of the mFAST features extracted from gas regions is different from that of other motion regions, we propose the Pixel-Per-Points (PPP) condition to further select candidate connected components.Experimental results show that the algorithm is able to effectively suppress most strong motion disturbances and achieve real-time leaking gas detection.

  4. Novel Methods of Hydrogen Leak Detection

    International Nuclear Information System (INIS)

    Pushpinder S Puri

    2006-01-01

    With the advent of the fuel cell technology and a drive for clean fuel, hydrogen gas is emerging as a leading candidate for the fuel of choice. For hydrogen to become a consumer fuel for automotive and domestic power generation, safety is paramount. It is, therefore, desired to have a method and system for hydrogen leak detection using odorant which can incorporate a uniform concentration of odorant in the hydrogen gas, when odorants are mixed in the hydrogen storage or delivery means. It is also desired to develop methods where the odorant is not added to the bulk hydrogen, keeping it free of the odorization additives. When odorants are not added to the hydrogen gas in the storage or delivery means, methods must be developed to incorporate odorant in the leaking gas so that leaks can be detected by small. Further, when odorants are not added to the stored hydrogen, it may also be desirable to observe leaks by sight by discoloration of the surface of the storage or transportation vessels. A series of novel solutions are proposed which address the issues raised above. These solutions are divided into three categories as follows: 1. Methods incorporating an odorant in the path of hydrogen leak as opposed to adding it to the hydrogen gas. 2. Methods where odorants are generated in-situ by chemical reaction with the leaking hydrogen 3. Methods of dispensing and storing odorants in high pressure hydrogen gas which release odorants to the gas at a uniform and predetermined rates. Use of one or more of the methods described here in conjunction with appropriate engineering solutions will assure the ultimate safety of hydrogen use as a commercial fuel. (authors)

  5. Prospects of Frequency-Time Correlation Analysis for Detecting Pipeline Leaks by Acoustic Emission Method

    International Nuclear Information System (INIS)

    Faerman, V A; Cheremnov, A G; Avramchuk, V V; Luneva, E E

    2014-01-01

    In the current work the relevance of nondestructive test method development applied for pipeline leak detection is considered. It was shown that acoustic emission testing is currently one of the most widely spread leak detection methods. The main disadvantage of this method is that it cannot be applied in monitoring long pipeline sections, which in its turn complicates and slows down the inspection of the line pipe sections of main pipelines. The prospects of developing alternative techniques and methods based on the use of the spectral analysis of signals were considered and their possible application in leak detection on the basis of the correlation method was outlined. As an alternative, the time-frequency correlation function calculation is proposed. This function represents the correlation between the spectral components of the analyzed signals. In this work, the technique of time-frequency correlation function calculation is described. The experimental data that demonstrate obvious advantage of the time-frequency correlation function compared to the simple correlation function are presented. The application of the time-frequency correlation function is more effective in suppressing the noise components in the frequency range of the useful signal, which makes maximum of the function more pronounced. The main drawback of application of the time- frequency correlation function analysis in solving leak detection problems is a great number of calculations that may result in a further increase in pipeline time inspection. However, this drawback can be partially reduced by the development and implementation of efficient algorithms (including parallel) of computing the fast Fourier transform using computer central processing unit and graphic processing unit

  6. Detection of steam generator tube leaks in pressurized water reactors

    International Nuclear Information System (INIS)

    Roach, W.H.

    1984-11-01

    This report addresses the early detection of small steam generator tube leaks in pressurized water reactors. It identifies physical parameters, establishes instrumentation performance goals, and specifies sensor types and locations. It presents a simple algorithm that yields the leak rate as a function of known or measurable quantities. Leak rates of less than one-tenth gram per second should be detectable with existing instrumentation

  7. Pipe Leak Detection Technology Development

    Science.gov (United States)

    The U. S. Environmental Protection Agency (EPA) has determined that one of the nation’s biggest infrastructural needs is the replacement or rehabilitation of the water distribution and transmission systems. The institution of more effective pipe leak detection technology will im...

  8. Current practice and developmental efforts for leak detection in U.S. reactor primary systems

    International Nuclear Information System (INIS)

    Kupperman, D.S.; Claytor, T.N.

    1986-01-01

    Current leak detection practices in 74 operating nuclear reactors have been reviewed. Existing leak detection systems are adequate to ensure a leak-before-break scenario in most situations, but no currently available, single method combines optimal leakage detection sensitivity, leak-locating ability, and leakage measurement accuracy. Simply tightening current leakage limits may produce an unacceptably large number of unnecessary shutdowns. The use of commercially available acoustic monitoring systems or moisture-sensitive tape may improve leak detection capability at specific sites. However, neither of these methods currently provides source discrimination (e.g., to distinguish between leaks from pipe cracks and valves) or leak-rate information (a small leak may saturate the system). A field-implementable acoustic leak detection system is being developed to address these limitations. 5 refs.

  9. 46 CFR 38.15-10 - Leak detection systems-T/ALL.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Leak detection systems-T/ALL. 38.15-10 Section 38.15-10... Requirements § 38.15-10 Leak detection systems—T/ALL. (a) A detection system shall be permanently installed to... exempt from the requirements of this paragraph. (b) The indicating instruments for the detection system...

  10. Minimum detectable gas concentration performance evaluation method for gas leak infrared imaging detection systems.

    Science.gov (United States)

    Zhang, Xu; Jin, Weiqi; Li, Jiakun; Wang, Xia; Li, Shuo

    2017-04-01

    Thermal imaging technology is an effective means of detecting hazardous gas leaks. Much attention has been paid to evaluation of the performance of gas leak infrared imaging detection systems due to several potential applications. The minimum resolvable temperature difference (MRTD) and the minimum detectable temperature difference (MDTD) are commonly used as the main indicators of thermal imaging system performance. This paper establishes a minimum detectable gas concentration (MDGC) performance evaluation model based on the definition and derivation of MDTD. We proposed the direct calculation and equivalent calculation method of MDGC based on the MDTD measurement system. We build an experimental MDGC measurement system, which indicates the MDGC model can describe the detection performance of a thermal imaging system to typical gases. The direct calculation, equivalent calculation, and direct measurement results are consistent. The MDGC and the minimum resolvable gas concentration (MRGC) model can effectively describe the performance of "detection" and "spatial detail resolution" of thermal imaging systems to gas leak, respectively, and constitute the main performance indicators of gas leak detection systems.

  11. High Altitude Aerial Natural Gas Leak Detection System

    Energy Technology Data Exchange (ETDEWEB)

    Richard T. Wainner; Mickey B. Frish; B. David Green; Matthew C. Laderer; Mark G. Allen; Joseph R. Morency

    2006-12-31

    The objective of this program was to develop and demonstrate a cost-effective and power-efficient advanced standoff sensing technology able to detect and quantify, from a high-altitude (> 10,000 ft) aircraft, natural gas leaking from a high-pressure pipeline. The advanced technology is based on an enhanced version of the Remote Methane Leak Detector (RMLD) platform developed previously by Physical Sciences Inc. (PSI). The RMLD combines a telecommunications-style diode laser, fiber-optic components, and low-cost DSP electronics with the well-understood principles of Wavelength Modulation Spectroscopy (WMS), to indicate the presence of natural gas located between the operator and a topographic target. The transceiver transmits a laser beam onto a topographic target and receives some of the laser light reflected by the target. The controller processes the received light signal to deduce the amount of methane in the laser's path. For use in the airborne platform, we modified three aspects of the RMLD, by: (1) inserting an Erbium-doped optical fiber laser amplifier to increase the transmitted laser power from 10 mW to 5W; (2) increasing the optical receiver diameter from 10 cm to 25 cm; and (3) altering the laser wavelength from 1653 nm to 1618 nm. The modified RMLD system provides a path-integrated methane concentration sensitivity {approx}5000 ppm-m, sufficient to detect the presence of a leak from a high capacity transmission line while discriminating against attenuation by ambient methane. In ground-based simulations of the aerial leak detection scenario, we demonstrated the ability to measure methane leaks within the laser beam path when it illuminates a topographic target 2000 m away. We also demonstrated simulated leak detection from ranges of 200 m using the 25 cm optical receiver without the fiber amplifier.

  12. Mass Spectrometric Calibration of Controlled Fluoroform Leak Rate Devices Technique and Uncertainty Analysis

    CERN Document Server

    Balsley, S D; Laduca, C A

    2003-01-01

    Controlled leak rate devices of fluoroform on the order of 10 sup - sup 8 atm centre dot cc sec sup - sup 1 at 25 C are used to calibrate QC-1 War Reserve neutron tube exhaust stations for leak detection sensitivity. Close-out calibration of these tritium-contaminated devices is provided by the Gas Dynamics and Mass Spectrometry Laboratory, Organization 14406, which is a tritium analytical facility. The mass spectrometric technique used for the measurement is discussed, as is the first principals calculation (pressure, volume, temperature and time). The uncertainty of the measurement is largely driven by contributing factors in the determination of P, V and T. The expanded uncertainty of the leak rate measurement is shown to be 4.42%, with a coverage factor of 3 (k=3).

  13. Acoustic leak detection at complicated topologies using neural netwoks

    International Nuclear Information System (INIS)

    Hessel, G.; Schmitt, W.; Weiss, F.P.

    1994-01-01

    Considering the shortcomings of all the existing leak detecting principles, a new method again based on the measurement of the leak induced sound but also applying pattern recognition is being developed. The capability of neural networks to localize leaks at the reactor pressure vessel (RPV) head of VVER-440 reactors is discussed. (orig./DG)

  14. Isotopic method of leaks detection in oil pipelines

    International Nuclear Information System (INIS)

    Listwam, W.; Mottl, J.

    1974-01-01

    Isotopic method of leaks detection in oil pipelines of diameter 200-800 mm is described. Tracer is injected into pipeline in the form of CH 3 Br 82 . After few hours one or two detectors are passed through pipeline to detect leaks. Detector set consists of scintillation radiometer with Na I/Tl crystal, electronic blecks with one-channel analyzer, recorder and storage batteries. Detector set is built on integrated circuits. (Z.M.)

  15. Leak detection systems for uranium mill tailings impoundments with synthetic liners

    International Nuclear Information System (INIS)

    Myers, D.A.; Tyler, S.W.; Gutknecht, P.J.; Mitchell, D.H.

    1983-09-01

    This study evaluated the performance of existing and alternative leak detection systems for lined uranium mill tailings ponds. Existing systems for detecting leaks at uranium mill tailings ponds investigated in this study included groundwater monitoring wells, subliner drains, and lysimeters. Three alternative systems which demonstrated the ability to locate leaks in bench-scale tests included moisture blocks, soil moisture probes, and a soil resistivity system. Several other systems in a developmental stage are described. For proper performance of leak detection systems (other than groundwater wells and lysimeters), a subgrade is required which assures lateral dispersion of a leak. Methods to enhance dispersion are discussed. Cost estimates were prepared for groundwater monitoring wells, subliner drain systems, and the three experimental systems. Based on the results of this report, it is suggested that groundwater monitoring systems be used as the primary means of leak detection. However, if a more responsive system is required due to site characteristics and groundwater quality criteria, subliner drains are applicable for ponds with uncovered liners. Leak-locating systems for ponds with covered liners require further development. Other recommendations are discussed in the report

  16. Leak detection and location in MONJU steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Saito, T; Kosugi, T [Prototype Reactor Office, Tokyo (Japan)

    1978-10-01

    Leak detection system of MONJU steam generator depends mostly on in-sodium hydrogen detectors. The requirements on leak detector performance are determined from the point of view of protecting tube leak propagation due to wastage, and the process of determining the performance is shown briefly. Research and development activities on in-sodium hydrogen detectors are described and the specifications of leak detectors for MONJU are also presented. In-cover-gas hydrogen detector and acoustic detector are under development. Research and development activities on the leak location after steam generator shutdown by such methods as an electromagnetic method and ultrasonic method are described. The results of the research and development work on inserting the test probes into tubes are described also. An idea for finding the condition of tubes in the neighbourhood of the leak is also presented. (author)

  17. Leak detection and location in MONJU steam generators

    International Nuclear Information System (INIS)

    Saito, T.; Kosugi, T.

    1978-01-01

    Leak detection system of MONJU steam generator depends mostly on in-sodium hydrogen detectors. The requirements on leak detector performance are determined from the point of view of protecting tube leak propagation due to wastage, and the process of determining the performance is shown briefly. Research and development activities on in-sodium hydrogen detectors are described and the specifications of leak detectors for MONJU are also presented. In-cover-gas hydrogen detector and acoustic detector are under development. Research and development activities on the leak location after steam generator shutdown by such methods as an electromagnetic method and ultrasonic method are described. The results of the research and development work on inserting the test probes into tubes are described also. An idea for finding the condition of tubes in the neighbourhood of the leak is also presented. (author)

  18. Development of acoustic leak detection system in PNC

    International Nuclear Information System (INIS)

    Tanabe, H.; Kuroha, M.

    1990-01-01

    The development of an acoustic leak detector is under way at PNC as a detection system that has potential of quick response and high reliability for larger steam generators of future LMFBR plants. The studies have two aspects, i.e., an acoustic wave analysis in various sodium-water reactions and a background noise (BGN) analysis in a sodium-heated 50MWt steam generator (50MWGS). In the former analysis, wave profiles of the sodium-water reaction sound were analyzed and compared with those of inert gas injection sound. The comparison revealed that there were no wave profiles specific to a sodium-water reaction sound. The latter clarified that major acoustic sources in the steam generator were sodium flow and steam generation/flow and that the water leak rate at which a noise level was comparable with that of the background noise was about 0.5 g/sec. in the evaporator of 50MWSG. The estimation of acceleration levels of BGN and leak sounds in other plants reveals that an intermediate leak is detectable in the Monju evaporator with a present acoustic detection system. (author). 2 refs, 9 figs

  19. Telescope sipping the optimum fuel leak detection system

    International Nuclear Information System (INIS)

    Deleryd, R.

    1998-01-01

    The TELESCOPE Sipping technology is an evolutionary development from previous ABB fuel leak systems used in LWR reactors. The system utilizes the existing dynamics that cause numerous fission products to leak from a failed fuel rod when the fuel assembly is raised from a reactor core during core fuel alterations. The system can also be used by repair work in pool side inspection in order to detect leaking rods or to verify reconstituted assemblies as non leakers. (author)

  20. An integrated leak detection system for the ALMR steam generator

    International Nuclear Information System (INIS)

    Dayal, Y.; Gaubatz, D.C.; Wong, K.K.; Greene, D.A.

    1995-01-01

    The steam generator (SG) of the Advanced Liquid Metal Reactor (ALMR) system serves as a heat exchanger between the shell side secondary loop hot liquid sodium and the tube side water/steam mixture. A leak in the tube will result in the injection of the higher pressure water/steam into the sodium and cause an exothermic sodium-water reaction. An initial small leak (less than 1 gm/sec) can escalate into an intermediate size leak in a relatively short time by self enlargement of the original flaw and by initiating leaks in neighboring tubes. If not stopped, complete rupture of one or more tubes can cause injection rates of thousands of gm/sec and result in the over pressurization of the secondary loop rupture disk and dumping of the sodium to relieve pressure. The down time associated with severe sodium-water reaction damage has great adverse economic consequence. An integrated leak detection system (ILDS) has been developed which utilizes both chemical and acoustic sensors for improved leak detection. The system provides SG leak status to the reactor operator and is reliable enough to trigger automatic control action to protect the SG. The ILDS chemical subsystem uses conventional in-sodium and cover gas hydrogen detectors and incorporates knowledge based effects due to process parameters for improved reliability. The ILDS acoustic subsystem uses an array of acoustic sensors and incorporates acoustic beamforming technology for highly reliable and accurate leak identification and location. The new ILDS combines the small leak detection capability of the chemical system with the reliability and rapid detection/location capability of the acoustic system to provide a significantly improved level of protection for the SG over a wide range of operation conditions. (author)

  1. Acoustic leak detection development in the USA

    International Nuclear Information System (INIS)

    Greene, D.A.; Malovrh, J.W.; Magee, P.M.

    1984-01-01

    Acoustic monitoring systems that detect and locate a leak of water/steam from a defective tube in an LMFBR steam generator have been developed in the United States. A low frequency (approx. 10 KHz) system was developed by General Electric, and a high frequency (200 to 300 KHz) system by Rockwell International with support from Argonne National Laboratory. A comprehensive base technology program provided absolute signal amplitudes, background noise amplitudes, and signal source-to-detector transfer functions. Field tests of these systems demonstrated an ability to detect and locate simulated leaks under operating and quiescent conditions in an LMFBR steam generator. (author)

  2. Acoustic leak detection in piping systems, 4

    International Nuclear Information System (INIS)

    Kitajima, Akira; Naohara, Nobuyuki; Aihara, Akihiko

    1983-01-01

    To monitor a high-pressure piping of nuclear power plants, a possibility of acoustic leak detection method has been experimentally studied in practical field tests and laboratory tests. Characteristics of background noise in field test and the results of experiment are summarized as follows: (1) The level of background noise in primary loop (PWR) was almost constant under actual plant operation. But it is possible that it rises at the condition of the pressure in primary loop. (2) Based on many experience of laboratory tests and practical field tests. The leak monitoring system for practical field was designed and developed. To improve the reliability, a judgment of leak on this system is used three factors of noise level, duration time of phenomena and frequency spectrum of noise signal emitted from the leak point. (author)

  3. Compressed air leak detection based on time delay estimation using a portable multi-sensor ultrasonic detector

    International Nuclear Information System (INIS)

    Liao, Pingping; Cai, Maolin; Shi, Yan; Fan, Zichuan

    2013-01-01

    The conventional ultrasonic method for compressed air leak detection utilizes a directivity-based ultrasonic leak detector (DULD) to locate the leak. The location accuracy of this method is low due to the limit of the nominal frequency and the size of the ultrasonic sensor. In order to overcome this deficiency, a method based on time delay estimation (TDE) is proposed. The method utilizes three ultrasonic sensors arranged in an equilateral triangle to simultaneously receive the ultrasound generated by the leak. The leak can be located according to time delays between every two sensor signals. The theoretical accuracy of the method is analyzed, and it is found that the location error increases linearly with delay estimation error and the distance from the leak to the sensor plane, and the location error decreases with the distance between sensors. The average square difference function delay estimator with parabolic fitting is used and two practical techniques are devised to remove the anomalous delay estimates. Experimental results indicate that the location accuracy using the TDE-based ultrasonic leak detector is 6.5–8.3 times as high as that using the DULD. By adopting the proposed method, the leak can be located more accurately and easily, and then the detection efficiency is improved. (paper)

  4. Helium Leak Test for the PLS Storage Ring Chamber

    International Nuclear Information System (INIS)

    Choi, M. H.; Kim, H. J.; Choi, W. C.

    1993-01-01

    The storage ring vacuum system for the Pohang Light Source (PLS) has been designed to maintain the vacuum pressure of 10 1 0 Torr which requires UHV welding to have helium leak rate less than 1x10 1 0 Torr·L/sec. In order to develop new technique (PLS) welding technique), a prototype vacuum chamber has been welded by using Tungsten Inert Gas welding method and all the welded joints have been tested with a non-destructive method, so called helium leak detection, to investigate the vacuum tightness of the weld joints. The test was performed with a detection limit of 1x10 1 0 Torr·L/sec for helium and no detectable leaks were found for all the welded joints. Thus the performance of welding technique is proven to meet the criteria of helium leak rate required in the PLS Storage Ring. Both the principle and the procedure for the helium leak detection are also discussed

  5. Demonstration of a Solution Film Leak Test Technique and Equipment for the S00645 Canister Closure

    International Nuclear Information System (INIS)

    Cannell, G.R.

    1999-01-01

    The purpose of this effort was to demonstrate that the SFT technique, when adapted to a DWPF canister nozzle, is capable of detecting leaks not meeting the Waste Acceptance Product Specifications (WAPS) acceptance criterion

  6. Remote leak detection for the TFTR

    International Nuclear Information System (INIS)

    Walthers, C.R.

    1977-01-01

    The planned design for the TFTR (TOKAMAK Fusion Test Reactor) remote leak detection system consists of a central console which controls the application of tracer gas to possible leak areas. Seals are tested by admitting tracer gas to machined cavities on the atmospheric side of the seal. The tracer gas is brought to the seal cavity by 1 / 8 -inch diameter tubes which connect to local tracer gas/vacuum manifolds located outside the protective radiation shielding. Vacuum shell walls and welds are checked by flowing tracer gas through annular heating/cooling passages. The detector will be either an MSLD (mass spectrometer leak detector) or an RGA (residual gas analyzer), the location of which is not finalized. Feasibility tests performed and planned include response and sensitivity measurements of possible tubing/detector configurations with several tracer gases

  7. Evaluation of primary coolant leaks and assessment of detection methods

    International Nuclear Information System (INIS)

    Cassette, P.; Giroux, C.; Roche, H.; Seveon, J.J.

    1986-01-01

    A review of the French PWR situation concerning primary coolant leaks is presented, including a description of operating technical specifications, of the collecting system of primary coolant leakage into the containment and of the detection methods. It is mainly based on a compilation over three years, 1981 to 1983, of almost all actual leaks, their natures, causes, consequences and methods used for their detection. By analysing these data it is possible to evaluate the efficiency of the primary coolant leak detection system and the problems raised by compliance with the criteria defined in the operating technical specifications

  8. Evaluation of primary coolant leaks and assessment of detection methods

    International Nuclear Information System (INIS)

    Cassette, P.; Giroux, C.; Roche, H.; Seveon, J.J.

    1984-11-01

    A review of French PWR situation concerning primary coolant leaks is presented, including a description of operating technical specifications, of the collecting system of primary coolant leakage into the containment and of the detection methods. It is mainly based on a compilation over three years, 1981 to 1983, of almost all occurred leaks, their natures, causes, consequences and methods used for their detection. By analysing these data it is possible to evaluate the efficiency of the primary coolant leak detection system and the problems raised by the compliance with the criteria defined in the operating technical specifications

  9. Mobile Sensor Networks for Leak and Backflow Detection in Water Distribution Systems

    KAUST Repository

    Suresh, M. Agumbe; Smith, L.; Rasekh, A.; Stoleru, R.; Banks, M.K.; Shihada, Basem

    2014-01-01

    Leak and backflow detection are essential aspects of Water Distribution System (WDS) monitoring. Most existing solutions for leak/backflow detection in WDSs focus on the placement of expensive static sensors located strategically. In contrast to these, we propose a solution whereby mobile sensors (i.e., their movement aided only by the inherent water flow in the system) detect leaks/backflow. Information about the leaks/backflow is collected from the sensors either by physically capturing them, or through wireless communication. Specifically, we propose models to maximize leak/backflow detection given a cost constraint (a limit on the number of sensors). Through extensive simulations, we demonstrate the superior performance of our proposed solution when compared with the state of the art solutions (e.g., algorithms/protocols and analysis).

  10. Mobile Sensor Networks for Leak and Backflow Detection in Water Distribution Systems

    KAUST Repository

    Suresh, M. Agumbe

    2014-05-01

    Leak and backflow detection are essential aspects of Water Distribution System (WDS) monitoring. Most existing solutions for leak/backflow detection in WDSs focus on the placement of expensive static sensors located strategically. In contrast to these, we propose a solution whereby mobile sensors (i.e., their movement aided only by the inherent water flow in the system) detect leaks/backflow. Information about the leaks/backflow is collected from the sensors either by physically capturing them, or through wireless communication. Specifically, we propose models to maximize leak/backflow detection given a cost constraint (a limit on the number of sensors). Through extensive simulations, we demonstrate the superior performance of our proposed solution when compared with the state of the art solutions (e.g., algorithms/protocols and analysis).

  11. Detection of leaks in buried rural water pipelines using thermal infrared images

    Science.gov (United States)

    Eidenshink, Jeffery C.

    1985-01-01

    Leakage is a major problem in many pipelines. Minor leaks called 'seeper leaks', which generally range from 2 to 10 m3 per day, are common and are difficult to detect using conventional ground surveys. The objective of this research was to determine whether airborne thermal-infrared remote sensing could be used in detecting leaks and monitoring rural water pipelines. This study indicates that such leaks can be detected using low-altitude 8.7- to 11.5. micrometer wavelength, thermal infrared images collected under proper conditions.

  12. A Sensitivity Analysis of a Computer Model-Based Leak Detection System for Oil Pipelines

    Directory of Open Access Journals (Sweden)

    Zhe Lu

    2017-08-01

    Full Text Available Improving leak detection capability to eliminate undetected releases is an area of focus for the energy pipeline industry, and the pipeline companies are working to improve existing methods for monitoring their pipelines. Computer model-based leak detection methods that detect leaks by analyzing the pipeline hydraulic state have been widely employed in the industry, but their effectiveness in practical applications is often challenged by real-world uncertainties. This study quantitatively assessed the effects of uncertainties on leak detectability of a commonly used real-time transient model-based leak detection system. Uncertainties in fluid properties, field sensors, and the data acquisition system were evaluated. Errors were introduced into the input variables of the leak detection system individually and collectively, and the changes in leak detectability caused by the uncertainties were quantified using simulated leaks. This study provides valuable quantitative results contributing towards a better understanding of how real-world uncertainties affect leak detection. A general ranking of the importance of the uncertainty sources was obtained: from high to low it is time skew, bulk modulus error, viscosity error, and polling time. It was also shown that inertia-dominated pipeline systems were less sensitive to uncertainties compared to friction-dominated systems.

  13. Development of Pipe Inspection Gauge (PIG) for leak detection in buried pipelines using radiotracer technique

    International Nuclear Information System (INIS)

    Pendharkar, A.S.; Sharma, V.K.; Pant, H.J.; Singh, Gursharan

    2004-01-01

    This paper discusses the development of a portable battery operated radioisotope based pipeline inspection gauge( PIG) for detection and location of leaks as well as to examine the condition of the underground pipelines. The system consists of a scintillation detector, power supply for detector and other electronic circuits. Pulse processing amplifier data acquisition system, readout unit and software to transfer data to computer for further processing. The microcontroller based pig is very useful in a field in an underground pipeline of 6 inch diameter and above. The battery operated pig system developed indigenously is rugged and portable with data storage capacity up to 20 hours. The system was tested under simulated leak conditions and field trials are being planned. (author)

  14. Experimental investigation of the utilisation of ionisation gauges for leak detection

    CERN Document Server

    Benvenuti, C

    1972-01-01

    A description is given of a method of leak detecting applicable to the ISR (CERN) vacuum system after bakeout. This method, based on the enhanced indication of an ionisation gauge obtained when replacing the air around the leak by Argon, affords a detection efficiency not lower than that obtainable by means of a traditional leak detector; furthermore it does not introduce contamination risks after bakeout. (4 refs).

  15. Pumping and leak detection system of the HL-2A

    International Nuclear Information System (INIS)

    Cao Zeng; Xu Yunxian; Fu Weidong

    2001-01-01

    The pumping system is a combination of 8 turbomolecular pumps with three stages pumping for HL-2A vacuum vessel, a total effective pumping speed at the vessel of 12 m 3 ·s -1 for nitrogen. The leak detection of element and vessel is performed with inspiration, case of leak detection and two mass spectrometry. The total leak rate of vessel is bellow 1 x 10 -5 Pa ·m 3 ·s -1 . The base pressure is 1 x 10 -5 Pa

  16. Fluid pipeline leak detection and location with miniature RF tags

    Science.gov (United States)

    McIntyre, Timothy J.

    2017-05-16

    Sensors locate troublesome leaks in pipes or conduits that carry a flowing medium. These sensors, through tailored physical and geometric properties, preferentially seek conduit leaks or breaches due to flow streaming. The sensors can be queried via transceivers outside the conduit or located and interrogated inside by submersible unmanned vehicle to identify and characterize the nature of a leak. The sensors can be functionalized with other capabilities for additional leak and pipeline characterization if needed. Sensors can be recovered from a conduit flow stream and reused for future leak detection activities.

  17. Fiber optic distributed chemical sensor for the real time detection of hydrocarbon fuel leaks

    Science.gov (United States)

    Mendoza, Edgar; Kempen, C.; Esterkin, Yan; Sun, Sunjian

    2015-09-01

    With the increase worldwide demand for hydrocarbon fuels and the vast development of new fuel production and delivery infrastructure installations around the world, there is a growing need for reliable hydrocarbon fuel leak detection technologies to provide safety and reduce environmental risks. Hydrocarbon leaks (gas or liquid) pose an extreme danger and need to be detected very quickly to avoid potential disasters. Gas leaks have the greatest potential for causing damage due to the explosion risk from the dispersion of gas clouds. This paper describes progress towards the development of a fast response, high sensitivity, distributed fiber optic fuel leak detection (HySense™) system based on the use of an optical fiber that uses a hydrocarbon sensitive fluorescent coating to detect the presence of fuel leaks present in close proximity along the length of the sensor fiber. The HySense™ system operates in two modes, leak detection and leak localization, and will trigger an alarm within seconds of exposure contact. The fast and accurate response of the sensor provides reliable fluid leak detection for pipelines, storage tanks, airports, pumps, and valves to detect and minimize any potential catastrophic damage.

  18. Detection of heavy-water leaks in nuclear reactors : a novel method

    International Nuclear Information System (INIS)

    Murthy, M.S.; Gor, M.K.

    2002-01-01

    Technical Physics and Prototype Engineering Division, BARC has designed, developed and produced several high sensitivity mass spectrometer helium leak detectors over a period of two decades. Sometimes back, when there was a problem of detecting heavy water leaks in situ in one of the nuclear power reactors of the Department of Atomic Energy, it was referred to this division for a technical solution. After discussing with the site engineers, the various problems involved in the on-line detection of heavy water leaks especially near the end fittings of the coolant assemblies, a novel method of leak detection was developed. Some of the salient features of the method and the results obtained in the laboratory tests are given in this paper. (author)

  19. Applying monitoring, verification, and accounting techniques to a real-world, enhanced oil recovery operational CO2 leak

    Science.gov (United States)

    Wimmer, B.T.; Krapac, I.G.; Locke, R.; Iranmanesh, A.

    2011-01-01

    The use of carbon dioxide (CO2) for enhanced oil recovery (EOR) is being tested for oil fields in the Illinois Basin, USA. While this technology has shown promise for improving oil production, it has raised some issues about the safety of CO2 injection and storage. The Midwest Geological Sequestration Consortium (MGSC) organized a Monitoring, Verification, and Accounting (MVA) team to develop and deploy monitoring programs at three EOR sites in Illinois, Indiana, and Kentucky, USA. MVA goals include establishing baseline conditions to evaluate potential impacts from CO2 injection, demonstrating that project activities are protective of human health and the environment, and providing an accurate accounting of stored CO2. This paper focuses on the use of MVA techniques in monitoring a small CO2 leak from a supply line at an EOR facility under real-world conditions. The ability of shallow monitoring techniques to detect and quantify a CO2 leak under real-world conditions has been largely unproven. In July of 2009, a leak in the pipe supplying pressurized CO2 to an injection well was observed at an MGSC EOR site located in west-central Kentucky. Carbon dioxide was escaping from the supply pipe located approximately 1 m underground. The leak was discovered visually by site personnel and injection was halted immediately. At its largest extent, the hole created by the leak was approximately 1.9 m long by 1.7 m wide and 0.7 m deep in the land surface. This circumstance provided an excellent opportunity to evaluate the performance of several monitoring techniques including soil CO2 flux measurements, portable infrared gas analysis, thermal infrared imagery, and aerial hyperspectral imagery. Valuable experience was gained during this effort. Lessons learned included determining 1) hyperspectral imagery was not effective in detecting this relatively small, short-term CO2 leak, 2) even though injection was halted, the leak remained dynamic and presented a safety risk concern

  20. Radiotracer technique for leakage detection under simulated conditions

    International Nuclear Information System (INIS)

    Yelgaonkar, V.N.; Sharma, V.K.; Tapase, A.S.

    2001-01-01

    Radiotracer techniques are often used to locate leaks in underground pipelines. An attempt was made to standardize radiotracer pulse migration in terms of minimum detectable limit. For this purpose a 6 inch diameter 1200 long steel pipe was used. Two leak rates viz. 10 litres per minute and 1 litre per minute with an accuracy of ± 10% were simulated. The experiments on this pipeline showed that this method could be used to locate a leak of the order of 1 litre per minute in a 6 inch diameter isolated underground pipeline. (author)

  1. Anastomotic leak detection by electrolyte electrical resistance.

    Science.gov (United States)

    DeArmond, Daniel T; Cline, Adam M; Johnson, Scott B

    2010-08-01

    To characterize a new method of postoperative gastrointestinal leak detection based on electrical resistance changes due to extravasated electrolyte contrast. Postoperative gastrointestinal leak results in increased patient morbidity, mortality, and hospital costs that can be mitigated by early diagnosis. A sensitive and specific diagnostic test that could be performed at the bedside has the potential to shorten the time to diagnosis and thereby improve the quality of treatment. Anaesthetized rats underwent celiotomy and creation of a 5-mm gastrotomy. In experimental animals, electrical resistance changes were measured with a direct current ohmmeter after the introduction of 5 cc of 23.4% NaCl electrolyte solution via gavage and measured with a more sensitive alternating current ohmmeter after the gavage of 1-5 cc of 0.9% NaCl. Comparison was made to negative controls and statistical analysis was performed. Leakage from the gastrotomy induced by as little as 1 cc of gavage-delivered 0.9% NaCl contrast solution was detectable as a statistically significant drop in electrical resistance when compared to results from negative controls. Electrical resistance change associated with electrolyte-gated leak detection is highly sensitive and specific and has the potential to be rapidly translated into clinical settings.

  2. Field test of a leak detection system: planning, execution and results

    Energy Technology Data Exchange (ETDEWEB)

    Sampaio da Silva; Daniel; Melo Filho, Silvio A.; Niehues de Farias, Mauro; Pacheco, Anderson [Petrobas Transporte SA - TRANSPETRO, (Brazil)

    2010-07-01

    The OLAPA pipeline (Brazil) with its 97.6 km in length crosses difficult environment with a combination of mountain and dense forest. The non-detection of leaks in this kind of pipeline would have serious consequences. This pipeline was chosen for testing the performance of a new TRANSPETRO leak detection system. This paper reports the testing process of the new leakage detection method carried out on the OLAPA pipeline. TRANSPETRO decided to test the leakwarn system which is a computational pipeline monitoring (CPM) method which and can be integrated into their SCADA system. The CPM uses the mass balance principle with line pack change to analyze the pipeline operational parameters. The tests consisted of comparing the theoretical results with in-field results of alarm times obtained from controlled removal of product, simulating a real leak. Three leaks were tested in different states of operation and size of leak. It was found that the results were compatible with the expected alarm time.

  3. Leak detection system design and operating considerations for the US-CRBRP

    International Nuclear Information System (INIS)

    Kruger, G.B.; Eng, K.Y.; Kelly, W.L.

    1976-01-01

    Diffusion membrane type hydrogen detectors are provided for monitoring the sodium exiting each evaporator and superheater in the Clinch River Breeder Reactor Plant. These detectors allow detection of small water to sodium leaks and provide the plant operator with an early warning signal. Hydrogen detectors are located at the exit sodium streams of each steam generator module, the vent from the module semi-stagnant region, the cold leg piping, and in an intermediate system sodium expansion tank cover gas region. In addition, an electrochemical oxygen detector is located in the cold leg piping. The leak detection system is capable of detecting the presence of steam/water leaks on the order of 0.45 x 10 -5 kg/sec or larger and of signaling within one to three minutes upon initiation of a leak, during normal operation. Operator action is taken upon receipt of a leak signal to shutdown the affected system, by closing steam/water isolation valves and depressurizing the affected unit

  4. 241-AY-102 Leak Detection Pit Drain Line Inspection Report

    International Nuclear Information System (INIS)

    Boomer, Kayle D.; Engeman, Jason K.; Gunter, Jason R.; Joslyn, Cameron C.; Vazquez, Brandon J.; Venetz, Theodore J.; Garfield, John S.

    2014-01-01

    This document provides a description of the design components, operational approach, and results from the Tank AY-102 leak detection pit drain piping visual inspection. To perform this inspection a custom robotic crawler with a deployment device was designed, built, and operated by IHI Southwest Technologies, Inc. for WRPS to inspect the 6-inch leak detection pit drain line

  5. Numerical Study on POSRV Leak Detection

    International Nuclear Information System (INIS)

    Ko, Yong Sang; Baik, Se Jin; Cho, Yoon Jae; Yune, Seok Jeong; Kim, Eun Kee

    2015-01-01

    This study shows that the selected temperature measuring locations on the discharge lines of MV, MOPV, SLPV0 and SLPV1 are adequate for POSRV leakage detection. The analyzed temperature can be used as an alarm setpoint for leakage detection. Spring-Loaded Pilot Valve (SLPV) acts as a Reactor Coolant Pressure Boundary (RCPB) isolator in the closed position during the normal operation, but it opens automatically when the system pressure increases to its set pressure. The POSRVs shall be closed tightly to maintain the integrity of RCPB during the normal operation. Leakage through the RCPB is limited extremely. Each POSRV has several discharge lines for MV and auxiliary valves. Temperature instruments are installed on each discharge lines for leakage detection. In this study, Computational Fluid Dynamics (CFD) analyses using FLUENT are conducted to evaluate the temperature measurement for POSRV leakage detection. The followings are concluded from this study: 1) The determined temperature measuring points are adequate for effective leak detection, which are at the downstream of the first bend of each discharge line as close as to the discharge nozzle. 2) The alarm set point for detecting a leak is adequate and can be determined with considering the analysis results. 3) The temperature rise is sufficiently high to detect a small leakage. 4) The temperature sensing method is appropriate for finding a valve leakage

  6. Water leak detection in steam generator of SUPER PHENIX

    International Nuclear Information System (INIS)

    Brunet, M.; Garnaud, P.; Ghaleb, D.; Kong, N.

    1988-01-01

    With the intent of detecting water leaks inside steam generators, we developed a third system, called acoustic detector, to complement hydrogen detectors and rupture disks (burst disks). The role of the acoustic system is to enable rapid intervention in the event of a leak growing rapidly which could rupture neighbouring tubes. In such a case, the detectable flow rate of the leak varies from a few tens of g/s to a few hundred g/s. At the SUPER PHENIX, three teams work in [20-100 kHz] and CEA/STA* [50-300 kHz]. The simulation of water leaks in the steam generator by the argon injections performed to date at 50% of the rated power has shown promising results. An anomaly in the evolution of the background noise at more than 50% loading of one of the two instrumented steam generators would make difficult any extrapolation to full power behaviour. (author)

  7. Leak Detection Modeling and Simulation for Oil Pipeline with Artificial Intelligence Method

    Directory of Open Access Journals (Sweden)

    Pudjo Sukarno

    2007-05-01

    Full Text Available Leak detection is always interesting research topic, where leak location and leak rate are two pipeline leaking parameters that should be determined accurately to overcome pipe leaking problems. In this research those two parameters are investigated by developing transmission pipeline model and the leak detection model which is developed using Artificial Neural Network. The mathematical approach needs actual leak data to train the leak detection model, however such data could not be obtained from oil fields. Therefore, for training purposes hypothetical data are developed using the transmission pipeline model, by applying various physical configuration of pipeline and applying oil properties correlations to estimate the value of oil density and viscosity. The various leak locations and leak rates are also represented in this model. The prediction of those two leak parameters will be completed until the total error is less than certain value of tolerance, or until iterations level is reached. To recognize the pattern, forward procedure is conducted. The application of this approach produces conclusion that for certain pipeline network configuration, the higher number of iterations will produce accurate result. The number of iterations depend on the leakage rate, the smaller leakage rate, the higher number of iterations are required. The accuracy of this approach is clearly determined by the quality of training data. Therefore, in the preparation of training data the results of pressure drop calculations should be validated by the real measurement of pressure drop along the pipeline. For the accuracy purposes, there are possibility to change the pressure drop and fluid properties correlations, to get the better results. The results of this research are expected to give real contribution for giving an early detection of oil-spill in oil fields.

  8. Real-Time Model-Based Leak-Through Detection within Cryogenic Flow Systems

    Science.gov (United States)

    Walker, M.; Figueroa, F.

    2015-01-01

    The timely detection of leaks within cryogenic fuel replenishment systems is of significant importance to operators on account of the safety and economic impacts associated with material loss and operational inefficiencies. Associated loss in control of pressure also effects the stability and ability to control the phase of cryogenic fluids during replenishment operations. Current research dedicated to providing Prognostics and Health Management (PHM) coverage of such cryogenic replenishment systems has focused on the detection of leaks to atmosphere involving relatively simple model-based diagnostic approaches that, while effective, are unable to isolate the fault to specific piping system components. The authors have extended this research to focus on the detection of leaks through closed valves that are intended to isolate sections of the piping system from the flow and pressurization of cryogenic fluids. The described approach employs model-based detection of leak-through conditions based on correlations of pressure changes across isolation valves and attempts to isolate the faults to specific valves. Implementation of this capability is enabled by knowledge and information embedded in the domain model of the system. The approach has been used effectively to detect such leak-through faults during cryogenic operational testing at the Cryogenic Testbed at NASA's Kennedy Space Center.

  9. TRANSANAL DRAINAGE OF ANASTOMOTIC LEAK FOLLOWING LOW ANTERIOR RESECTION- A NOVEL TECHNIQUE

    Directory of Open Access Journals (Sweden)

    Vinay Boppasamudra Nanjegowda

    2017-03-01

    Full Text Available BACKGROUND Anastomotic leaks after low anterior resection following rectal cancer is the major cause for morbidity and mortality. Various techniques for the conservative management of localised abscesses have been reported, but with variable results. Hence, in search of a new technique to treat anastomotic leak following low anterior resection, which is cost-effective and has good results. MATERIALS AND METHODS This study is a retrospective review of a prospectively maintained data of a novel technique to treat anastomotic leaks after low anterior resection with proximal diverting ileostomy in a single institution. RESULTS A total of 40 patients who underwent low anterior resection with diversion ileostomy for rectal cancer were studied. In them, 6 patients developed Grade B anastomotic leak, which were managed by this novel technique of paediatric endoscopic-guided transanal drainage of anastomotic leak following low anterior resection with diversion ileostomy using a 3-way Foley catheter. All the patients responded well, thus leading to local control of the septic foci without the need for any further radiological intervention or a laparotomy. This lead to salvaging the anastomosis. Out of the 6 patients managed by this technique, one patient developed stricture, which was managed by CRE balloon dilatation. All patients underwent stoma closure after a median postoperative time of 7 months. CONCLUSION Under paediatric endoscopic guidance, transanal drainage of anastomotic leak with an abscess cavity using a 3-way Foley catheter after low anterior resection with double-staple technique prevents further disruption of the anastomosis and local irrigation leads to faster sepsis control thus avoiding the morbidity of relaparotomy. This technique being a bedside procedure is cost-effective and feasible. This leads to good salvage of anastomosis along with early stoma closure and good long-term functional results.

  10. Detecting Methane From Leaking Pipelines and as Greenhouse Gas in the Atmosphere

    Science.gov (United States)

    Riris, Haris; Numata, Kenji; Li, Steven; Wu, Stewart; Ramanathan, Anand; Dawsey, Martha

    2012-01-01

    Laser remote sensing measurements of trace gases from orbit can provide unprecedented information about important planetary science and answer critical questions about planetary atmospheres. Methane (CH4) is the second most important anthropogenically produced greenhouse gas. Though its atmospheric abundance is much less than that of CO2 (1.78 ppm vs. 380 ppm), it has much larger greenhouse heating potential. CH4 also contributes to pollution in the lower atmosphere through chemical reactions, leading to ozone production. Atmospheric CH4 concentrations have been increasing as a result of increased fossil fuel production, rice farming, livestock, and landfills. Natural sources of CH4 include wetlands, wild fires, and termites, and perhaps other unknown sources. Important sinks for CH4 include non-saturated soils and oxidation by hydroxyl radicals in the atmosphere. Remotely measuring CH4 and other biogenic molecules (such as ethane and formaldehyde) on Mars also has important implications on the existence of life on Mars. Measuring CH4 at very low (ppb) concentrations from orbit will dramatically improve the sensitivity and spatial resolution in the search for CH4 vents and sub-surface life on other planets. A capability has been developed using lasers and spectroscopic detection techniques for the remote measurements of trace gases in open paths. Detection of CH4, CO2, H2O, and CO in absorption cells and in open paths, both in the mid- IR and near-IR region, has been demonstrated using an Optical Parametric Amplifier laser transmitter developed at GSFC. With this transmitter, it would be possible to develop a remote sensing methane instrument. CH4 detection also has very important commercial applications. Pipeline leak detection from an aircraft or a helicopter can significantly reduce cost, response time, and pinpoint the location. The main advantage is the ability to rapidly detect CH4 leaks remotely. This is extremely important for the petrochemical industry

  11. Ultrasensitive leak detection during ultrahigh vacuum evacuation by quadrupole mass spectrometer

    International Nuclear Information System (INIS)

    Chen Xu; Huang Tianbin; Wang Ligong; Jin Qiji; Cha Liangzhen

    2006-01-01

    One must do ultrasensitive leak detection during ultrahigh-vacuum (UHV) evacuation, especially just before the device is sealed off from the vacuum system, to guarantee the longevity of the sealed high-vacuum or even UHV devices with small volume. A quadrupole mass spectrometer (QMS) with an UHV evacuation system can be used under accumulation mode to do the testing. Possible accumulate modes, as well as their advantages and shortcomings, are studied experimentally and discussed in this paper. We found that the opening action of the metal valve during accumulation mode always severely affects the height of the peak indicated by QMS and causes considerable errors. If we determine the leak rate by the peak area instead of the peak height, the situation is much improved. This method has proven quite useful in ensuring the tightness quality for complex sealed UHV devices with small volumes. Ultrasensitive leak detection has been carried out for such real evacuating devices, and a leak rate of 2x10 -14 Pa·m 3 /s was detected, which is far lower than its dynamic mode and the detection limit of the current advanced commercial leak detectors

  12. Detecting subsurface fluid leaks in real-time using injection and production rates

    Science.gov (United States)

    Singh, Harpreet; Huerta, Nicolas J.

    2017-12-01

    CO2 injection into geologic formations for either enhanced oil recovery or carbon storage introduces a risk for undesired fluid leakage into overlying groundwater or to the surface. Despite decades of subsurface CO2 production and injection, the technologies and methods for detecting CO2 leaks are still costly and prone to large uncertainties. This is especially true for pressure-based monitoring methods, which require the use of simplified geological and reservoir flow models to simulate the pressure behavior as well as background noise affecting pressure measurements. In this study, we propose a method to detect the time and volume of fluid leakage based on real-time measurements of well injection and production rates. The approach utilizes analogies between fluid flow and capacitance-resistance modeling. Unlike other leak detection methods (e.g. pressure-based), the proposed method does not require geological and reservoir flow models to simulate the behavior that often carry significant sources of uncertainty; therefore, with our approach the leak can be detected with greater certainty. The method can be applied to detect when a leak begins by tracking a departure in fluid production rate from the expected pattern. The method has been tuned to detect the effect of boundary conditions and fluid compressibility on leakage. To highlight the utility of this approach we use our method to detect leaks for two scenarios. The first scenario simulates a fluid leak from the storage formation into an above-zone monitoring interval. The second scenario simulates intra-reservoir migration between two compartments. We illustrate this method to detect fluid leakage in three different reservoirs with varying levels of geological and structural complexity. The proposed leakage detection method has three novelties: i) requires only readily-available data (injection and production rates), ii) accounts for fluid compressibility and boundary effects, and iii) in addition to

  13. EBR-II water-to-sodium leak detection system

    International Nuclear Information System (INIS)

    Wrightson, M.M.; McKinley, K.; Ruther, W.E.; Holmes, J.T.

    1976-01-01

    The water-to-sodium leak detection system installed at EBR-II in April, 1975, is described in detail. Topics covered include operational characteristics, maintenance problems, alarm functions, background hydrogen level data, and future plans for refinements to the system. Particular emphasis is given to the failures of eight of the ten leak detectors due to sodium-to-vacuum leakage, and the program anticipated for complete recovery of the system

  14. SmartPipes: Smart Wireless Sensor Networks for Leak Detection in Water Pipelines

    Directory of Open Access Journals (Sweden)

    Ali M. Sadeghioon

    2014-02-01

    Full Text Available Asset monitoring, specifically infrastructure monitoring such as water distribution pipelines, is becoming increasingly critical for utility owners who face new challenges due to an aging network. In the UK alone, during the period of 2009–2010, approximately 3281 mega litres (106 of water were wasted due to failure or leaks in water pipelines. Various techniques can be used for the monitoring of water distribution networks. This paper presents the design, development and testing of a smart wireless sensor network for leak detection in water pipelines, based on the measurement of relative indirect pressure changes in plastic pipes. Power consumption of the sensor nodes is minimised to 2.2 mW based on one measurement every 6 h in order to prolong the lifetime of the network and increase the sensor nodes’ compatibility with current levels of power available by energy harvesting methods and long life batteries. A novel pressure sensing method is investigated for its performance and capabilities by both laboratory and field trials. The sensors were capable of measuring pressure changes due to leaks. These pressure profiles can also be used to locate the leaks.

  15. Management of vacuum leak-detection processes, calibration, and standards

    International Nuclear Information System (INIS)

    Wilson, N.G.

    1985-01-01

    Vacuum leak detection requires integrated management action to ensure the successful production of apparatus having required leak tightness. Implementation of properly planned, scheduled, and engineered procedures and test arrangements are an absolute necessity to prevent unexpected, impractical, technically inadequate, or unnecessarily costly incidents in leak-testing operations. The use of standard procedures, leak standards appropriate to the task, and accurate calibration systems or devices is necessary to validate the integrity of any leak-test procedure. In this paper, the need for implementing these practices is discussed using case histories of typical examples of large complex vacuum systems. Aggressive management practices are of primary importance throughout a project's life cycle to ensure the lowest cost; this includes successful leak testing of components. It should be noted that the opinions and conclusions expressed in this paper are those of the author and are not those of the Los Alamos National Laboratory or the Department of Energy

  16. Helium leak testing of scanning electron microscope

    International Nuclear Information System (INIS)

    Ahmad, Anis; Tripathi, S.K.; Mukherjee, D.

    2015-01-01

    Scanning Electron Microscope (SEM) is a specialized electron-optical device which is used for imaging of miniscule features on topography of material specimens. Conventional SEMs used finely focused high energy (about 30 KeV) electron beam probes of diameter of about 10nm for imaging of solid conducting specimens. Vacuum of the order of 10"-"5 Torr is prerequisite for conventional Tungsten filament type SEMs. One such SEM was received from one of our laboratory in BARC with a major leak owing to persisting poor vacuum condition despite continuous pumping for several hours. He-Leak Detection of the SEM was carried out at AFD using vacuum spray Technique and various potential leak joints numbering more than fifty were helium leak tested. The major leak was detected in the TMP damper bellow. The part was later replaced and the repeat helium leak testing of the system was carried out using vacuum spray technique. The vacuum in SEM is achieved is better than 10"-"5 torr and system is now working satisfactorily. (author)

  17. Leak detection in steam generators with hydrogen monitors using diffusion membranes

    Energy Technology Data Exchange (ETDEWEB)

    Hissink, M

    1975-07-01

    Large water leaks in steam-generators give rise to violent chemical reactions which can only be controlled by a pressure relief system. Smaller leaks do not pose direct safety hazards but wastage of pipes surrounding the leak should be prevented. Leak detection is best carried out by monitors recording the hydrogen in sodium content. For large leaks the specification of these monitors causes no problems, contrary to those for the timely detection of small leaks. Essential parameters are sensitivity and speed of response, specificity is less important. But apart from the instrument specification, a number of factors, related to the construction and operation of the steam-generator, determine the performance of the leak detection system. A discussion of these factors is given, with a view to the design of the SNR-300. Although tile results of many theoretical studies and experimental work are available, there seems to be room for further investigations on the growths of minor leaks. Also lacking a sufficient experience concerning the level and fluctuations of the hydrogen background in the sodium. A description is given of the hydrogen monitor developed at TNO, which is based on a combination of a nickel membrane and an ion getter pump. The parameters of this instrument have been evaluated in a test rig. Operational experience with the monitor is available from the 50 MW Test Facility at Hengelo. Especially for further studies the need for a calibrated instrument has become apparent. Test are going on with a modified design of a monitor meeting this requirement. (author)

  18. 40 CFR 63.1087 - What actions must I take if a leak is detected?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 10 2010-07-01 2010-07-01 false What actions must I take if a leak is... leak is detected? If a leak is detected, you must comply with the requirements in paragraphs (a) and (b) of this section unless repair is delayed according to § 63.1088. (a) Repair the leak as soon as...

  19. [Gas pipeline leak detection based on tunable diode laser absorption spectroscopy].

    Science.gov (United States)

    Zhang, Qi-Xing; Wang, Jin-Jun; Liu, Bing-Hai; Cai, Ting-Li; Qiao, Li-Feng; Zhang, Yong-Ming

    2009-08-01

    The principle of tunable diode laser absorption spectroscopy and harmonic detection technique was introduced. An experimental device was developed by point sampling through small multi-reflection gas cell. A specific line near 1 653. 7 nm was targeted for methane measurement using a distributed feedback diode laser as tunable light source. The linearity between the intensity of second harmonic signal and the concentration of methane was determined. The background content of methane in air was measured. The results show that gas sensors using tunable diode lasers provide a high sensitivity and high selectivity method for city gas pipeline leak detection.

  20. Water leak detection in steam generator of Super Phenix

    International Nuclear Information System (INIS)

    Kong, N.; Brunet, M.; Garnaud, P.; Ghaleb, D.

    1990-01-01

    With the intent of detecting water leaks inside steam generators, we developed a third system, called acoustic detector, to complement hydrogen detectors and rupture disks (burst disks). The role of the acoustic system is to enable rapid intervention in the event of a leak growing rapidly which could rupture neighbouring tubes. In such a case, the detectable flow rate of the leak varies from a few tens of g/s to a few hundred g/s. At the Super Phenix, three teams work in parallel in complementary frequency bands: EDF (0-20 kHz), CEA/SPCI (20-100 kHz) and CEA/STA (50-300 kHz). The simulation of water leaks in the steam generator by the argon injections performed to date at 50% of the rated power has shown promising results. An anomaly in the evolution of the background noise at more than 50% loading of one of the two instrumented steam generators would make difficult any extrapolation to full power behaviour. 5 refs, 6 figs, 1 tab

  1. Development of the On-line Acoustic Leak Detection Tool for the SFR Steam Generator Protection

    International Nuclear Information System (INIS)

    Kim, Tae-Joon; Jeong, Ji-Young; Kim, Jong-Man; Kim, Byung-Ho; Kim, Seong-O

    2007-01-01

    The successful detection of a water/steam into a sodium leak in the SFR SG (steam generator) at an early phase of a leak origin depends on the fast response and sensitivity of a leak detection system. This intention of an acoustic leak detection system is stipulated by a key impossibility of a fast detecting of an intermediate leak by the present nominal systems such as the hydrogen meter. Subject of this study is to introduce the detection performance of an on-line acoustic leak detection tool discriminated by a back-propagation neural network with a preprocessing of the 1/m Octave band analysis, and to introduce the status of an on-line development being developed with the acoustic leak detection tool(S/W) in KAERI. For a performance test, it was used with the acoustic signals for a sodium-water reaction from the injected steam into water experiments in KAERI, the acoustic signals injected from the water into the sodium obtained in IPPE, and the background noise of the PFR superheater

  2. Sensitive helium leak detection in a deuterium atmosphere using a high-resolution quadrupole mass spectrometer

    International Nuclear Information System (INIS)

    Hiroki, S.; Abe, T.; Murakami, Y.

    1996-01-01

    In fusion machines, realizing a high-purity plasma is a key to improving the plasma parameters. Thus, leak detection is a necessary part of reducing the leak rate to a tolerable level. However, a conventional helium ( 4 He) leak detector is useless in fusion machines with a deuterium (D 2 ) plasma, because retained D particles on the first walls release D 2 for a long period and the released D 2 interferes with the signals from the leaked 4 He due to the near identical masses of 4.0026 u ( 4 He) and 4.0282 u (D 2 ). A high-resolution quadrupole mass spectrometer (HR-QMS) that we have recently developed, can detect a 4 He + population as small as 10 -4 peak in a D 2 atmosphere. Thus, the HR-QMS has been applied to detect 4 He leaks. To improve the minimum detectable limit of 4 He leak, a differentially pumped HR-QMS analyzer was attached to a chamber of the 4 He leak detector. In conclusion, the improved 4 He leak detector could detect 4 He leaks of the order of 10 -10 Pa · m 3 /s in a D 2 atmosphere. (Author)

  3. Design of a leak detection device for marine airtight container

    Science.gov (United States)

    Li, Yuan; Zhu, Faxin; Lu, Jinshu; Li, Yule; Wu, Wenfeng; Zhang, Jianwei; Qin, Beichen

    2018-04-01

    The ship airtight container as the research object, according to the tightness of the traditional detection methods of sealed container from the shortcomings of the design of modern ship sealed container leak detection device based on the requirements of the use of AutoCAD to design a ship leakage detection device using airtight container, and introduces its working principle and main components. Finally, from the aspects of technology, structure, operation and economy, the feasibility analysis of the leak detection device for marine airtight container is designed, and it is concluded that the device has the advantages of simple operation, short detection time, easy maintenance and cost control, and has high feasibility.

  4. A Hybrid Heuristic Optimization Approach for Leak Detection in Pipe Networks Using Ordinal Optimization Approach and the Symbiotic Organism Search

    Directory of Open Access Journals (Sweden)

    Chao-Chih Lin

    2017-10-01

    Full Text Available A new transient-based hybrid heuristic approach is developed to optimize a transient generation process and to detect leaks in pipe networks. The approach couples the ordinal optimization approach (OOA and the symbiotic organism search (SOS to solve the optimization problem by means of iterations. A pipe network analysis model (PNSOS is first used to determine steady-state head distribution and pipe flow rates. The best transient generation point and its relevant valve operation parameters are optimized by maximizing the objective function of transient energy. The transient event is created at the chosen point, and the method of characteristics (MOC is used to analyze the transient flow. The OOA is applied to sift through the candidate pipes and the initial organisms with leak information. The SOS is employed to determine the leaks by minimizing the sum of differences between simulated and computed head at the observation points. Two synthetic leaking scenarios, a simple pipe network and a water distribution network (WDN, are chosen to test the performance of leak detection ordinal symbiotic organism search (LDOSOS. Leak information can be accurately identified by the proposed approach for both of the scenarios. The presented technique makes a remarkable contribution to the success of leak detection in the pipe networks.

  5. The leak detection and location system design of petroleum pipeline

    International Nuclear Information System (INIS)

    Liu Lixia

    2011-01-01

    In order to improve the sensibility and location precision of petroleum pipeline leak with traditional negative pressure wave detection, a multi-point distributed detection and location monitoring system composed of detection nodes along pipeline, monitoring sub-stations and pressure monitoring center was designed using C/S structure. The detection node gets the pressure signal in pipeline, and sends it to monitoring center through CPRS network that achieves online monitoring for the whole pipeline in real time. The received data was analyzed and processed with multi-point distributed negative pressure wave detection and correlation analysis method. The system can rapidly detect the leak point in pipeline timely and locate accurately to avoid enormous economic loss and environment pollutions accidents. (author)

  6. Leak detection device for nuclear reactor pressure vessel

    International Nuclear Information System (INIS)

    Ikeda, Jun.

    1988-01-01

    Purpose: To test the leakage of a nuclear reactor pressure vessel during stopping for a short period of time with no change to the pressure vessel itself. Constitution: The device of the present invention comprises two O-rings disposed on the flange surface that connects a pressure vessel main body and an upper cover, a leak-off pipeway derived from the gap of the O-rings at the flange surface to the outside of the pressure vessel, a pressure detection means connected to the end of the pipeway, a humidity detection means disposed to the lead-off pipeway, a humidity detection means disposed to the lead-off pipeway, and gas supply means and gas suction means disposed each by way of a check valve to a side pipe branched from the pipeway. After stopping the operation of the nuclear reactor and pressurizing the pressure vessel by filling water, gases supplied to the gap between the O-rings at the flange surface by opening the check valve. In a case where water in the pressure vessel should leak to the flange surface, when gas suction is applied by properly opening the check valve, increase in the humidity due to the steams of leaked water diffused into the gas is detected to recognize the occurrence of leakage. (Kamimura, M.)

  7. Diagnostic instrumentation for detection of the onset of steam tube leaks in PWRs

    International Nuclear Information System (INIS)

    Roach, W.H.

    1984-01-01

    Four tasks are addressed in this study of the detection of steam tube leaks: determination of which physical parameters indicate the onset of steam generator tube leaks; establishing performance goals for diagnostic instruments which could be used for early detection of steam generator tube leaks; defining the diagnostic instrumentation and their location which satisfy Items 1 and 2; and assessing the need for diagnostic data processing and display. Parameters are identified, performance goals established and sensor types and locations are specified in the report, with emphasis on the use of existing instrumentation with a minimum of retrofitting. A simple algorithm is developed which yields the leak rate as a function of known or measurable quantities. The conclusion is that leak rates of less than one-tenth gram per second should be detectable with existing instrumentation

  8. Development of the double-wall-tube steam generator. Evaluation of inner tube leak detection system

    International Nuclear Information System (INIS)

    Teraoku, Takuji; Kisohara, Naoyuki

    1995-01-01

    A double-wall-tube steam generator (DWT-SG) is considered to have possibility of eliminating a secondary heat transport system to realize a reliable and simplified FBR plant. Thus, basic tests for inner/outer tube leak detection and prototypical leak tests by use of the 1MWt DWT-SG model have been performed to evaluate the feasibility of DWT-SG. Their results demonstrated that the inner leak detection system can definitely detect a steam leak from an inner tube flaw. Analyses of the inner tube leak and detection behavior obtained in the 1MWt DWT-SG test enabled to estimate the performance of the inner tube detection system of the commercial DWT-SG system. (author)

  9. White gauze test: a novel technique in preventing post-hepatectomy bile leak.

    Science.gov (United States)

    Yugasaravanan, K; Affirul, C A; Zamri, Z; Azlanudin, A; Bong, J J

    Post-hepatectomy bile leak may lead to undesired morbidity. Multiple methods have been employed to identify this leak but can be inconclusive and taxing. This novel white gauze test is a simple and reliable method. This is a prospective study performed from January 2010 until March 2011. All open hepatic resection were included. Dry white gauze is compressed onto the transected surface and observed for bile staining. The leaking duct is repaired immediately upon detection. The process is repeated until negative. Drain was removed on postoperative day-5. Post-operative bile leak is defined as: 1. Bilirubin concentration of the drain fluid is 3 times or higher than serum; 2. Presence of intra-abdominal bile collection on imaging and upon drainage; 3. Bile leak demonstrated on postoperative cholangiography. 42 patients were recruited. Seven (16.7%) patients were cirrhotic with Child-Pugh A. White gauze test were positive for intra-operative bile leaks in 29 patients (70%), which were primarily repaired. As a result, there was no postoperative bile leak in this series. One mortality was detected in this series due to postoperative pancreatic fistula and multi organ failure. The White Gauze Test is a useful method for the prevention of bile leakage after hepatic resection. It is safe, quick and cheap.

  10. Percutaneous Treatment of Intrahepatic Biliary Leak: A Modified Occlusion Balloon Technique

    Energy Technology Data Exchange (ETDEWEB)

    Nasser, Felipe; Rocha, Rafael Dahmer, E-mail: rafaeldrocha@gmail.com; Falsarella, Priscila Mina; Motta-Leal-Filho, Joaquim Maurício da; Azevedo, André Arantes; Valle, Leonardo Guedes Moreira; Cavalcante, Rafael Noronha; Garcia, Rodrigo Gobbo; Affonso, Breno Boueri; Galastri, Francisco Leonardo [Hospital Israelita Albert Einstein, Department of Interventional Radiology (Brazil)

    2016-05-15

    PurposeTo report a novel modified occlusion balloon technique to treat biliary leaks.MethodsA 22-year-old female patient underwent liver transplantation with biliary-enteric anastomosis. She developed thrombosis of the common hepatic artery and extensive ischemia in the left hepatic lobe. Resection of segments II and III was performed and a biliary-cutaneous leak originating at the resection plane was identified in the early postoperative period. Initial treatment with percutaneous transhepatic drainage was unsuccessful. Therefore, an angioplasty balloon was coaxially inserted within the biliary drain and positioned close to the leak.ResultsThe fistula output abruptly decreased after the procedure and stopped on the 7th day. At the 3-week follow-up, cholangiography revealed complete resolution of the leakage.ConclusionThis novel modified occlusion balloon technique was effective and safe. However, greater experience and more cases are necessary to validate the technique.

  11. Hydrogen Leak Detection Sensor Database

    Science.gov (United States)

    Baker, Barton D.

    2010-01-01

    This slide presentation reviews the characteristics of the Hydrogen Sensor database. The database is the result of NASA's continuing interest in and improvement of its ability to detect and assess gas leaks in space applications. The database specifics and a snapshot of an entry in the database are reviewed. Attempts were made to determine the applicability of each of the 65 sensors for ground and/or vehicle use.

  12. Leak detection system for a high temperature fluid pipe

    International Nuclear Information System (INIS)

    Puyal, C.; Meuwisse, C.

    1989-01-01

    The leak detection system is made by a cable with at least two isolated electrical conductors, close to the wall of the pipe. The material of the cable is chosen so as to change its electrical characteristics if a leak causes heating of the cable. A detector at one end of the cable can measure the modifications of the electrical characteristics [fr

  13. Water Pipeline Monitoring and Leak Detection using Flow Liquid Meter Sensor

    Science.gov (United States)

    Rahmat, R. F.; Satria, I. S.; Siregar, B.; Budiarto, R.

    2017-04-01

    Water distribution is generally installed through underground pipes. Monitoring the underground water pipelines is more difficult than monitoring the water pipelines located on the ground in open space. This situation will cause a permanent loss if there is a disturbance in the pipeline such as leakage. Leaks in pipes can be caused by several factors, such as the pipe’s age, improper installation, and natural disasters. Therefore, a solution is required to detect and to determine the location of the damage when there is a leak. The detection of the leak location will use fluid mechanics and kinematics physics based on harness water flow rate data obtained using flow liquid meter sensor and Arduino UNO as a microcontroller. The results show that the proposed method is able to work stably to determine the location of the leak which has a maximum distance of 2 metres, and it’s able to determine the leak location as close as possible with flow rate about 10 litters per minute.

  14. Detection of non-stationary leak signals at NPP primary circuit by cross-correlation analysis

    International Nuclear Information System (INIS)

    Shimanskij, S.B.

    2007-01-01

    A leak-detection system employing high-temperature microphones has been developed for the RBMK and ATR (Japan) reactors. Further improvement of the system focused on using cross-correlation analysis of the spectral components of the signal to detect a small leak at an early stage of development. Since envelope processes are less affected by distortions than are wave processes, they give a higher-degree of correlation and can be used to detect leaks with lower signal-noise ratios. Many simulation tests performed at nuclear power plants have shown that the proposed methods can be used to detect and find the location of a small leak [ru

  15. Leak Detection in Heat Exchangers and Underground Pipelines Using Radiotracers. Material for Education and On-The-Job Training for Practitioners of Radiotracer Technology

    International Nuclear Information System (INIS)

    2009-01-01

    The International Atomic Energy Agency plays a major role in facilitating the transfer of radiotracer technology to developing Member States. The use of radiotracer techniques is well established in many Member States; some hundred radiotracer and end user specialists have been trained in radiotracer techniques and their applications; nearly 50 radiotracer laboratories have been working in this field. The training of radiotracer practitioners is vital for the provision of quality services to industry. Leak detection using radiotracer techniques is probably one of the most widespread applications of radiotracers in industrial troubleshooting. Radiotracer techniques are the most competitive for online leak inspection of heat exchangers and buried pipelines. Radiotracers help in early detection of leaks in heat exchangers and underground transporting pipelines, thus saving money, reducing shutdown time, ensuring safe operation and protecting the environment from pollution. The training course series on leak detection in heat exchangers and underground pipelines using radiotracers addresses the needs of the radiotracer groups and their end users. Besides training purposes, this material will assist radiotracer groups in establishing their quality control and accreditation systems. This training course material is based on lecture notes and practical work delivered by many experts in IAEA-supported activities. In particular, the Technical Cooperation Projects implemented under the Regional Cooperative Agreement (RCA) of the IAEA Member States in the Asia and the Pacific Region have been successful in transferring and implementing radiotracer techniques for leak detection to many end users from oil and gas production, oil refineries and the petrochemical industry. The experience obtained in the RCA Region is presented in the training material illustrated with many case studies carried out in several RCA Member States. Lectures and case studies were reviewed by a number

  16. Steam generator leak detection using acoustic method

    International Nuclear Information System (INIS)

    Goluchko, V.V.; Sokolov, B.M.; Bulanov, A.N.

    1982-05-01

    The main requirements to meet by a device for leak detection in sodium - water steam generators are determined. The potentialities of instrumentation designed based on the developed requirements have been tested using a model of a 550 kw steam generator [fr

  17. Method and apparatus for continuous fluid leak monitoring and detection in analytical instruments and instrument systems

    Science.gov (United States)

    Weitz, Karl K [Pasco, WA; Moore, Ronald J [West Richland, WA

    2010-07-13

    A method and device are disclosed that provide for detection of fluid leaks in analytical instruments and instrument systems. The leak detection device includes a collection tube, a fluid absorbing material, and a circuit that electrically couples to an indicator device. When assembled, the leak detection device detects and monitors for fluid leaks, providing a preselected response in conjunction with the indicator device when contacted by a fluid.

  18. An optical sensor for the detection of leaks from subsea pipelines and risers

    International Nuclear Information System (INIS)

    McStay, D; Kerlin, J; Acheson, R

    2007-01-01

    An optical sensor for the rapid detection of detect leaks of oil, hydraulic fluids or leak detection chemicals from underwater pipelines and risers is reported. The sensor is designed to be deployed on ROVs or AUVs for the rapid survey of underwater pipelines and risers. The system employs ultra-bright LEDs to project a sensing light beam into the water to allow real time detection of ppm concentration plumes of material leaking from pipelines or riser in real time. Typically the system is deployed on an ROV which inspects a pipeline at a height of 2-3m

  19. The Development of Leak Test Techniques by Means Helium Detector

    International Nuclear Information System (INIS)

    Sigit Asmara Santa; Puradwi lsmu Wahyono; Deddy Haryanto; Joko Irianto; Ismu Handoyo

    2003-01-01

    The auxiliary vacuum tube used for helium leak detection has been designed. The aim is to increase measured leak test sensitivity of existing helium leak detection system from the level of 10 -3 ∼10 -5 standard cm 3 /second to 10 -8 ∼10 -10 standard cm 3 /second. The goals of installed auxiliary vacuum tube in the existing leak detection system are used for quality control test product of Fission Product Molybdenum (FPM) capsule and AgInCd safety control rod. The design requirements were established based on both of their quality control test requirement to assure their safety and reliability. The vacuum tube length was designed at least as long as 100 cm with 6 inch diameter and have leakage tightness till as low as 10 10 standard cm 3 /second. The temperature and pressure could be controlled up to 100 o C and negative pressure 10 inch Hg respectively. The vacuum tube was equipped with temperature controller system consisting of covered heater and installed 3 thermocouples which were evenly distributed along the length of tube. Pressure control system controls the inside pressure vacuum tube according to prior setpoint values. Vacuum tube temperature and pressure were controlled using combination of both prior its set-up temperature and pressure. Aluminum disks were installed at the end of covered heater used for cooling system and to protect heat hazard to operator. (author)

  20. A Sensitivity Analysis of a Computer Model-Based Leak Detection System for Oil Pipelines

    OpenAIRE

    Zhe Lu; Yuntong She; Mark Loewen

    2017-01-01

    Improving leak detection capability to eliminate undetected releases is an area of focus for the energy pipeline industry, and the pipeline companies are working to improve existing methods for monitoring their pipelines. Computer model-based leak detection methods that detect leaks by analyzing the pipeline hydraulic state have been widely employed in the industry, but their effectiveness in practical applications is often challenged by real-world uncertainties. This study quantitatively ass...

  1. Leak detection in turbo group condensers using helium

    International Nuclear Information System (INIS)

    Gomez Cores, C.; Lloret, J.

    1997-01-01

    This method allows a rapid location of leaks (small or not) in the pipelines of a turbo group condenser, before opening the condenser boxes and no need of stooping the turbo group operation. This operation can last two hours maximum depending on the volume of the box or semi box. The technique consists of injecting helium into the water side and detecting it in the steam side, in the outlet of not condensable gases of the ejector. In the same way, probable air inlet to the condenser can be proved (auxiliary systems, turbo group joints to the condenser, etc.) in order to improve the vacuum and/or reduce the quantity of oxygen dissolved in the water of the steam side. (author) [es

  2. Electrical detection of liquid lithium leaks from pipe joints

    Energy Technology Data Exchange (ETDEWEB)

    Schwartz, J. A., E-mail: jschwart@pppl.gov; Jaworski, M. A.; Mehl, J.; Kaita, R.; Mozulay, R. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543-0451 (United States)

    2014-11-15

    A test stand for flowing liquid lithium is under construction at Princeton Plasma Physics Laboratory. As liquid lithium reacts with atmospheric gases and water, an electrical interlock system for detecting leaks and safely shutting down the apparatus has been constructed. A defense in depth strategy is taken to minimize the risk and impact of potential leaks. Each demountable joint is diagnosed with a cylindrical copper shell electrically isolated from the loop. By monitoring the electrical resistance between the pipe and the copper shell, a leak of (conductive) liquid lithium can be detected. Any resistance of less than 2 kΩ trips a relay, shutting off power to the heaters and pump. The system has been successfully tested with liquid gallium as a surrogate liquid metal. The circuit features an extensible number of channels to allow for future expansion of the loop. To ease diagnosis of faults, the status of each channel is shown with an analog front panel LED, and monitored and logged digitally by LabVIEW.

  3. A study on multi-data source fusion method for petroleum pipeline leak detection

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Wei; Zhang, Laibin [Research Center of Oil and Gas Safety Engineering Technology, China University of Petroleum, Beijing, (China)

    2010-07-01

    The detection of leaks on petroleum pipeline is a very important safety issue. Several studies were commissioned to develop new monitoring procedures for leakage detection. This paper sets out a new leak detection process. The approach developed took into consideration steady and transient states. The study investigated leak diagnosis problems in product pipelines using multi-sensor measurements (pressure, flux, density and temperature). The information collected from each sensor was considered as pieces of evidence that describe the operational conditions of the pipeline. The Dempster-Shafer (D-S) theory is used to associate multi-sensor data to pipe health indices. Experimental pressure and flow rate data were recorded using a Pipeline Leak Detection System (PLDS) acquisition card and used to verify the accuracy and reliability of this new detection method. The results showed that the degree of credibility was a high as 0.877. It was also found that multi-feature information fusion improves recognition of pipeline conditions.

  4. Leak detection method for long pipeline based on dynamic pressure and wavelet analysis

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Bin; Wang, Likun; Wang, Hongchao; Xiong, Min; Yu, Dongliang; Tan, Dongjie [RnD center of PetroChina Pipeline Company, Langfang, Hebei, (China)

    2010-07-01

    Leaks appear frequently in pipelines, raising the possibility of safety issues. The detection of pipeline leakage is very important for the pipeline industry. This paper investigated a leak detection method on a long pipeline using a dynamic pressure sensor. A new leakage system is proposed based on the measurements obtained from this dynamic pressure sensor. The data were analyzed using the wavelet transformation method. First, the signal provided by the pressure sensor its denoised and then leaks are detected from the presence of singularities in the signal. Field tests were carried out on a product oil pipeline of 94 km length. The in-field test results showed that the minimum ratio of detectable leakage is 0.6 % of throughput and the location error is below 300 m. The response time is less than 120 seconds. This new system has been applied in 5000 km pipelines in China and is proving its efficiency in detecting leak points.

  5. Development of leak detection system using high temperature-resistant microphones

    International Nuclear Information System (INIS)

    Morishita, Yoshitsugu; Mochizuki, Hiroyasu; Watanabe, Kenshiu; Nakamura, Takahisa; Nakazima, Yoshiaki; Yamauchi, Tatsuya

    1995-01-01

    This report describes the development and testing of a coolant leak detection system for an inlet feeder pipe of an advanced thermal reactor (ATR) using high temperature-resistant microphones. Such microphones must be resistant to both high temperatures and high radiation doses. Leakage sound characteristics, attenuation of the sound level in a heat insulating box for the inlet feeder pipes, and background noise were investigated using the experimental facility and the prototype ATR 'FUGEN'. The optimum frequency ranges for the microphone were then determined based on the observed leakage sound and background noise. The ability of the microphone to discriminate between leaks and other burst-type noises was also investigated by statistical analyses. Finally, it was confirmed that the present method could detect a leak within a couple of seconds. (author)

  6. Designing a reliable leak bio-detection system for natural gas pipelines

    International Nuclear Information System (INIS)

    Batzias, F.A.; Siontorou, C.G.; Spanidis, P.-M.P.

    2011-01-01

    Monitoring of natural gas (NG) pipelines is an important task for economical/safety operation, loss prevention and environmental protection. Timely and reliable leak detection of gas pipeline, therefore, plays a key role in the overall integrity management for the pipeline system. Owing to the various limitations of the currently available techniques and the surveillance area that needs to be covered, the research on new detector systems is still thriving. Biosensors are worldwide considered as a niche technology in the environmental market, since they afford the desired detector capabilities at low cost, provided they have been properly designed/developed and rationally placed/networked/maintained by the aid of operational research techniques. This paper addresses NG leakage surveillance through a robust cooperative/synergistic scheme between biosensors and conventional detector systems; the network is validated in situ and optimized in order to provide reliable information at the required granularity level. The proposed scheme is substantiated through a knowledge based approach and relies on Fuzzy Multicriteria Analysis (FMCA), for selecting the best biosensor design that suits both, the target analyte and the operational micro-environment. This approach is illustrated in the design of leak surveying over a pipeline network in Greece.

  7. Designing a reliable leak bio-detection system for natural gas pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Batzias, F.A., E-mail: fbatzi@unipi.gr [Univ. Piraeus, Dept. Industrial Management and Technology, Karaoli and Dimitriou 80, 18534 Piraeus (Greece); Siontorou, C.G., E-mail: csiontor@unipi.gr [Univ. Piraeus, Dept. Industrial Management and Technology, Karaoli and Dimitriou 80, 18534 Piraeus (Greece); Spanidis, P.-M.P., E-mail: pspani@asprofos.gr [Asprofos Engineering S.A, El. Venizelos 284, 17675 Kallithea (Greece)

    2011-02-15

    Monitoring of natural gas (NG) pipelines is an important task for economical/safety operation, loss prevention and environmental protection. Timely and reliable leak detection of gas pipeline, therefore, plays a key role in the overall integrity management for the pipeline system. Owing to the various limitations of the currently available techniques and the surveillance area that needs to be covered, the research on new detector systems is still thriving. Biosensors are worldwide considered as a niche technology in the environmental market, since they afford the desired detector capabilities at low cost, provided they have been properly designed/developed and rationally placed/networked/maintained by the aid of operational research techniques. This paper addresses NG leakage surveillance through a robust cooperative/synergistic scheme between biosensors and conventional detector systems; the network is validated in situ and optimized in order to provide reliable information at the required granularity level. The proposed scheme is substantiated through a knowledge based approach and relies on Fuzzy Multicriteria Analysis (FMCA), for selecting the best biosensor design that suits both, the target analyte and the operational micro-environment. This approach is illustrated in the design of leak surveying over a pipeline network in Greece.

  8. A survey on the state-of-the-technique on software based pipeline leak detection systems

    Energy Technology Data Exchange (ETDEWEB)

    Baptista, Renan Martins [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil). Centro de Pesquisas. Div. de Explotacao]. E-mail: renan@cenpes.petrobras.com.br

    2000-07-01

    This paper describes a general technical survey on software based leak detection systems (LDS), approaching its main technological features, the operational situations where they are feasible, and the scenarios within the Brazilian pipeline network. The decision on what LDS to choose for a given pipeline is a matter of cost, suitability and feasibility. A simpler low cost, less effective product, but with a fast installation and tuning procedure, may be more suitable for a given operational site (pipeline configuration, kind of fluid, quality of instrumentation and communication), than a complex, high cost, efficient product, but taking a long time to be properly installed. Some other may really have a level of complexity that will require a more sophisticated system. A few number of them will simply not be suitable to have a LDS: it may be caused by the poor quality or absence of instrumentation, or, the worst case, due to the lack of technology to approach that specific case, e. g., multiphase flow lines, or those lines that commonly operates in slack condition. It is intended to approach here the general state-of-the-technique and make some initial comments on the costs. (author)

  9. Results of Tank-Leak Detection Demonstration Using Geophysical Techniques at the Hanford Mock Tank Site-Fiscal Year 2001

    International Nuclear Information System (INIS)

    Barnett, D BRENT.; Gee, Glendon W.; Sweeney, Mark D.

    2002-01-01

    During July and August of 2001, Pacific Northwest National Laboratory (PNNL), hosted researchers from Lawrence Livermore and Lawrence Berkeley National laboratories, and a private contractor, HydroGEOPHYSICS, Inc., for deployment of the following five geophysical leak-detection technologies at the Hanford Site Mock Tank in a Tank Leak Detection Demonstration (TLDD): Electrical Resistivity Tomography (ERT); Cross-Borehole Electromagnetic Induction (CEMI) ; High-Resolution Resistivity (HRR); Cross-Borehole Radar (XBR); Cross-Borehole Seismic Tomography (XBS). Under a ''Tri-party Agreement'' with Federal and state regulators, the U.S. Department of Energy will remove wastes from single-shell tanks (SSTs) and other miscellaneous underground tanks for storage in the double-shell tank system. Waste retrieval methods are being considered that use very little, if any, liquid to dislodge, mobilize, and remove the wastes. As additional assurance of protection of the vadose zone beneath the SSTs, tank wastes and tank conditions may be aggressively monitored during retrieval operations by methods that are deployed outside the SSTs in the vadose zone

  10. The current status of research and development concerning steam generator acoustic leak detection for the demonstration FBR plant

    International Nuclear Information System (INIS)

    Higuchi, Masahisa

    1990-01-01

    The Japan Atomic Power Co. (JAPC) started the research and development into Acoustic Leak Detection for the Demonstration FBR (D-FBR) plant in 1989. Acoustic Leak Detection is expected as a water leak detection system in the Steam Generator for the first D-FBR plant. JAPC is presently analyzing data on Acoustic Leak Detection in order to form some basic concepts and basic specifications about leak detection. Both low frequency types and high frequency types are selected as candidates for Acoustic Leak Detection. After a review of both types, either one will be selected for the D-FBT plant. A detailed Research and Development plan on Acoustic Leak Detection, which should be carried out prior to starting the construction of the D-FBR plant, is under review. (author). 3 figs, 2 tabs

  11. Acoustic feedwater heater leak detection: Industry application of low ampersand high frequency detection increases response and reliability

    International Nuclear Information System (INIS)

    Woyshner, W.S.; Bryson, T.; Robertson, M.O.

    1993-01-01

    The Electric Power Research Institute has sponsored research associated with acoustic Feedwater Heater Leak Detection since the early 1980s. Results indicate that this technology is economically beneficial and dependable. Recent research work has employed acoustic sensors and signal conditioning with wider frequency range response and background noise elimination techniques to provide increased accuracy and dependability. Dual frequency sensors have been applied at a few facilities to provide information on this application of dual frequency response. Sensor mounting methods and attenuation due to various mounting configurations are more conclusively understood. These are depicted and discussed in detail. The significance of trending certain plant parameters such as heat cycle flows, heater vent and drain valve position, proper relief valve operation, etc. is also addressed. Test data were collected at various facilities to monitor the effect of varying several related operational parameters. A group of FWHLD Users have been involved from the inception of the project and reports on their latest successes and failures, along with various data depicting early detection of FWHLD tube leaks, will be included. 3 refs., 12 figs., 1 tab

  12. Heavy water leak detection using diffusion sampler

    International Nuclear Information System (INIS)

    Joshi, M.L.; Hussain, S.A.

    1990-01-01

    In the Pressurrised Heavy Water Reactors (PHWRs) detection of the sources of heavy water leaks is importent both for the purpose of radiation hazard control as well as for the reduction of escape/loss of heavy water which, is an expensive nuclear material. This paper describes an application of tritium diffusion sampler for heavy water leak detection. The diffusion sampler comprises an usual tritium counting glass vial with a special orifice. The counting vial has water vapour, deficient in HTO concentration. The HTO present outside diffuses in the vial through the orifice, gets exchanged with water of the wet filter paper kept at the bottom and the moisture in the vial atmosphere which has HTO concentration lower than that outside. This results in continuation of net movement of HTO in the vial. The exchanged tritium is counted in liquid scintillation spectrometer. The method has a sensitivity of 10000 dpm/DAC-h. (author). 2 figs., 2 ta bs

  13. Fault diagnosis and refrigerant leak detection in vapour compression refrigeration systems

    Energy Technology Data Exchange (ETDEWEB)

    Tassou, S.A.; Grace, I.N. [Brunel University, Uxbridge (United Kingdom). Department of Mechanical Engineering

    2005-08-01

    The environmental impact of refrigeration systems can be reduced by operation at higher efficiency and reduction of refrigerant leakage. Refrigerant loss contributes both directly and indirectly to global warming through inefficient system operation, increased power consumption and greenhouse gas emissions and higher maintenance costs. Existing sensor-based leak detection methods are limited by the inability to detect gradual leakage and the need for careful sensor location. There is a requirement for a real-time performance monitoring approach to leak detection and fault diagnosis which overcomes these disadvantages. This paper reports on the development of a fault diagnosis and refrigerant leak detection system based on artificial intelligence and real-time performance monitoring. The system has been used successfully to distinguish between faulty and fault free operation, steady-state and transient operation, leakage and over charge conditions. Work currently underway is aimed at testing additional fault conditions and establishing further rules to distinguish between these patterns. (author)

  14. HIGH RESOLUTION RESISTIVITY LEAK DETECTION DATA PROCESSING and EVALUATION MEHTODS and REQUIREMENTS

    International Nuclear Information System (INIS)

    SCHOFIELD JS

    2007-01-01

    This document has two purposes: (sm b ullet) Describe how data generated by High Resolution REsistivity (HRR) leak detection (LD) systems deployed during single-shell tank (SST) waste retrieval operations are processed and evaluated. (sm b ullet) Provide the basic review requirements for HRR data when Hrr is deployed as a leak detection method during SST waste retrievals

  15. Leak Detection and Location of Water Pipes Using Vibration Sensors and Modified ML Prefilter.

    Science.gov (United States)

    Choi, Jihoon; Shin, Joonho; Song, Choonggeun; Han, Suyong; Park, Doo Il

    2017-09-13

    This paper proposes a new leak detection and location method based on vibration sensors and generalised cross-correlation techniques. Considering the estimation errors of the power spectral densities (PSDs) and the cross-spectral density (CSD), the proposed method employs a modified maximum-likelihood (ML) prefilter with a regularisation factor. We derive a theoretical variance of the time difference estimation error through summation in the discrete-frequency domain, and find the optimal regularisation factor that minimises the theoretical variance in practical water pipe channels. The proposed method is compared with conventional correlation-based techniques via numerical simulations using a water pipe channel model, and it is shown through field measurement that the proposed modified ML prefilter outperforms conventional prefilters for the generalised cross-correlation. In addition, we provide a formula to calculate the leak location using the time difference estimate when different types of pipes are connected.

  16. Leak Detection and Location of Water Pipes Using Vibration Sensors and Modified ML Prefilter

    Directory of Open Access Journals (Sweden)

    Jihoon Choi

    2017-09-01

    Full Text Available This paper proposes a new leak detection and location method based on vibration sensors and generalised cross-correlation techniques. Considering the estimation errors of the power spectral densities (PSDs and the cross-spectral density (CSD, the proposed method employs a modified maximum-likelihood (ML prefilter with a regularisation factor. We derive a theoretical variance of the time difference estimation error through summation in the discrete-frequency domain, and find the optimal regularisation factor that minimises the theoretical variance in practical water pipe channels. The proposed method is compared with conventional correlation-based techniques via numerical simulations using a water pipe channel model, and it is shown through field measurement that the proposed modified ML prefilter outperforms conventional prefilters for the generalised cross-correlation. In addition, we provide a formula to calculate the leak location using the time difference estimate when different types of pipes are connected.

  17. Status of U.S. evaluations of acoustic detection of in-sodium water leaks

    International Nuclear Information System (INIS)

    Fletcher, F.L.; Neely, H.H.

    1990-01-01

    An overview of the United States testing program to evaluate acoustic leak detection and location systems on simulated water leaks in functional liquid sodium steam generators is provided. Testing was conducted on the modular hockey stick steam generator during the large leak test program in the LLTR, on the CRBR prototype hockey stick steam generators in SCTI, on a double wall tube steam generator installed in EBR-II and on the helical coil steam generator tested in SCTI. These test programs have demonstrated the acoustic leak detection system potential, however, additional development is required before the system can perform to its effective and required potential. (author). 6 figs

  18. Acoustic Leak Detection Testing Using KAERI Sodium-Water Reaction Signals for a SFR Steam Generator

    International Nuclear Information System (INIS)

    Kim, Tae-Joon; Jeong, Ji-Young; Kim, Jong-Man; Kim, Byung-Ho; Hahn, Do-Hee; Yugay, Valeriy S.

    2009-01-01

    The results of an experimental study of water in a sodium leak noise spectrum formation at 0.004-0.54 g/sec, various rates of water into a sodium leak, smaller than 1.0 g/sec, are presented. We focused on studying a micro leak detection with an increasing rate of water into sodium. On the basis of the experimental leak noise data manufactured in KAERI the simple dependency of an acoustic signal level from the rate of a micro and small leak at different frequency bands is presented to understand the principal analysis for the development of an acoustic leak detection methodology used in a K- 600 steam generator

  19. Test Plan for the Demonstration of Geophysical Techniques for Single-Shell Tank Leak Detection at the Hanford Mock Tank Site: Fiscal Year 2001

    Energy Technology Data Exchange (ETDEWEB)

    Barnett, D. Brent; Gee, Glendon W.; Sweeney, Mark D.

    2001-07-31

    As part of the Leak Detection, Monitoring and Mitigation (LDMM) program conducted by CH2M HILL 105-A during FY 2001. These tests are being conducted to assess the applicability of these methods (Electrical Resistance Tomography [ERT], High Resolution Resistivity [HRR], Cross-Borehole Seismography [XBS], Cross-Borehole Radar [XBR], and Cross-Borehole Electromagnetic Induction [CEMI]) to the detection and measurement of Single Shell Tank (SST) leaks into the vadose zone during planned sluicing operations. The testing in FY 2001 will result in the selection of up to two methods for further testing in FY 2002. In parallel with the geophysical tests, a Partitioning Interwell Tracer Test (PITT) study will be conducted simultaneously at the Mock Tank to assess the effectiveness of this technology in detecting and quantifying tank leaks in the vadose zone. Preparatory and background work using Cone Penetrometer methods (CPT) will be conducted at the Mock Tank site and an adjacent test area to derive soil properties for groundtruthing purposes for all methods.

  20. Detection of pressure tube leaks relying on moisture beetles only

    International Nuclear Information System (INIS)

    Kenchington, J.M.; Choi, A.; Jin, Y.

    2004-01-01

    A major decision was made for Pickering NGS A Annulus Gas System (ACS) that detection of a pressure tube (PT) leak should be achieved by using only moisture beetles and that dew point monitors would provide 'early warning' without status to shut down the reactor. Experience with Unit 3 has shown that dew point monitoring of pressure tube leaks was particularly subject to gas leaks and surface adsorption effects. Unit 4 was the first one to be converted during the full scale pressure tube replacement programme. Because of the fundamental change in design philosophy, moisture injection tests were carried out during commissioning to demonstrate that performance matched design. In particular it was necessary to show that leak before break (LBB) would be achieved if a leak occurred in the limiting string. Units 1 and 3 have since been converted. No decision has been taken to convert Pickering B units as gas leaks are small and no significant adsorption effects are anticipated. Hence dew point monitoring will not be impaired. (author)

  1. Detecting and correcting pipeline leaks before they become a big problem

    OpenAIRE

    Cramer, R; Shaw, D; Tulalian, R; Angelo, P; van Stuijvenberg, M

    2015-01-01

    Timely pipeline leak detection is a significant business issue in view of a long history of catastrophic incidents and growing intolerance for such events. It is vital to flag containment loss and location quickly, credibly, and reliably for all green or brown field critical lines in order to shut down the line safely and isolate the leak. Pipelines are designed to transport hydrocarbons safely; however, leaks have severe safety, economic, environmental, and reputational effects. This paper w...

  2. Localized leak detection utilizing moisture sensitive tape

    International Nuclear Information System (INIS)

    Riddle, P.

    1984-01-01

    Moisture sensitive tape (MST) has been used in various nuclear power plants to detect leaks in reactor piping systems. The sensor assembly consists of MST, transponder, and sensor carrier, and is installed on the exterior of thermal insulation. The components, applications, installation, and purchasing information are discussed in the paper

  3. Effect of a Background Noise on the Acoustic Leak Detection Methodology for a SFR Steam Generator

    International Nuclear Information System (INIS)

    Kim, Tae-Joon; Jeong, Ji-Young; Kim, Jong-Man

    2007-01-01

    The protection of a water/steam leak into a sodium in the SFR SG at an early phase of a leak origin depends on a fast response and sensitivity of a leak detection system not to a response against the several kinds of noises. The subject in this study is to introduce a detection performance by using our developed acoustic leak detection methodology discriminated by a backpropagation neural network according to a preprocessing of the 1/6 Octave band analysis or 1/12 Octave band analysis and the x n method defined by us. It was used for the acoustic signals generated from the simulation works which are the noises of an artificial background such as a scratching, a hammering on a steel structure and so on. In a previous study, we showed that the performance of a LabVIEW tool embedded with the developed acoustic leak detection methodology detected the SWR leak signals

  4. Airborne pipeline leak detection: UV or IR?

    Science.gov (United States)

    Babin, François; Gravel, Jean-François; Allard, Martin

    2016-05-01

    This paper presents a study of different approaches to the measurement of the above ground vapor plume created by the spill caused by a small 0.1 l/min (or less) leak in an underground liquid petroleum pipeline. The scenarios are those for the measurement from an airborne platform. The usual approach is that of IR absorption, but in the case of liquid petroleum products, there are drawbacks that will be discussed, especially when using alkanes to detect a leak. The optical measurements studied include UV enhanced Raman lidar, UV fluorescence lidar and IR absorption path integrated lidars. The breadboards used for testing the different approaches will be described along with the set-ups for leak simulation. Although IR absorption would intuitively be the most sensitive, it is shown that UV-Raman could be an alternative. When using the very broad alkane signature in the IR, the varying ground spectral reflectance are a problem. It is also determined that integrated path measurements are preferred, the UV enhanced Raman measurements showing that the vapor plume stays very close to the ground.

  5. Detection and on-line prediction of leak magnitude in a gas pipeline using an acoustic method and neural network data processing

    Directory of Open Access Journals (Sweden)

    R. B. Santos

    2014-03-01

    Full Text Available Considering the importance of monitoring pipeline systems, this work presents the development of a technique to detect gas leakage in pipelines, based on an acoustic method, and on-line prediction of leak magnitude using artificial neural networks. On-line audible noises generated by leakage were obtained with a microphone installed in a 60 m long pipeline. The sound noises were decomposed into sounds of different frequencies: 1 kHz, 5 kHz and 9 kHz. The dynamics of these noises in time were used as input to the neural model in order to determine the occurrence and the leak magnitude. The results indicated the great potential of the technique and of the developed neural network models. For all on-line tests, the models showed 100% accuracy in leak detection, except for a small orifice (1 mm under 4 kgf/cm² of nominal pressure. Similarly, the neural network models could adequately predict the magnitude of the leakages.

  6. Doppler method leak detection for LMFBR steam generators. Pt. 3. Investigation of detection sensitivity and method

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi; Kinoshita, Izumi

    2001-01-01

    To prevent the expansion of tube damage and to maintain structural integrity in the steam generators (SGs) of a fast breeder reactor (FBR), it is necessary to detect precisely and immediately any leakage of water from heat transfer tubes. Therefore, the Doppler method was developed. Previous studies have revealed that, in the SG full-sector model that simulates actual SGs, the Doppler method can detect bubbles of 0.4 l/s within a few seconds. However in consideration of the dissolution rate of hydrogen generated by a sodium-water reaction even from a small water leak, it is necessary to detect smaller leakages of water from the heat transfer tubes. The detection sensitivity of the Doppler method and the influence of background noise were experimentally investigated. In-water experiments were performed using the SG model. The results show that the Doppler method can detect bubbles of 0.01 l/s (equivalent to a water leak rate of about 0.01 g/s) within a few seconds and that the background noise has little effect on water leak detection performance. The Doppler method thus has great potential for the detection of water leakage in SGs. (author)

  7. PRACTICAL IMPLICATIONS OF USING INDUCED TRANSIENTS FOR LEAK DETECTION

    Directory of Open Access Journals (Sweden)

    Marko V. Ivetic

    2007-06-01

    Full Text Available This paper deals with practical problems of leak detection by methods based on hydraulic transient analysis. Controlled and safe transients can be generated and the response of the network, with the relevant information, can be monitored and analysed. Information about leaks, contained in the monitored pressure signal, cannot be easily retrieved, due to reflections, noise etc. On the basis of numerical experiments on a simple network, merits and limitations of several methods for signal analysis (time domain analysis, spectral density function and wavelet transform have been examined. Certain amount of information can be extracted from the time history of the pressure signal, assuming the first reflection of the pressure wave is captured with very high time resolution and accuracy. Only relatively large leaks can be detected using this methodology. As a way to increase the sensitivity of this method it is suggested that transforms in frequency domain and, especially, wavelet transforms, are used. The most promising method for leakage location and quantification seems to be based on wavelet analysis.

  8. PRACTICAL IMPLICATIONS OF USING INDUCED TRANSIENTS FOR LEAK DETECTION

    Directory of Open Access Journals (Sweden)

    Marko V. Ivetic

    2007-01-01

    Full Text Available This paper deals with practical problems of leak detection by methods based on hydraulic transient analysis. Controlled and safe transients can be generated and the response of the network, with the relevant information, can be monitored and analysed. Information about leaks, contained in the monitored pressure signal, cannot be easily retrieved, due to reflections, noise etc. On the basis of numerical experiments on a simple network, merits and limitations of several methods for signal analysis (time domain analysis, spectral density function and wavelet transform have been examined. Certain amount of information can be extracted from the time history of the pressure signal, assuming the first reflection of the pressure wave is captured with very high time resolution and accuracy. Only relatively large leaks can be detected using this methodology. As a way to increase the sensitivity of this method it is suggested that transforms in frequency domain and, especially, wavelet transforms, are used. The most promising method for leakage location and quantification seems to be based on wavelet analysis.

  9. Acoustic system for pipe rupture monitoring and leak detection

    International Nuclear Information System (INIS)

    Herzog, W.; Jonas, H.

    1982-06-01

    As a safety aspect pipe rupture and leakage effects are of particular interest in nuclear power plants where severe consequences for the reactor may result. Counter measures against postulated pipe breaks and leakages in nuclear power plants are necessary whenever the main safety goals: safe shut-down, safe afterheat removal and retention of radioactivity, are endangered. The requirements to be met by a leak detection system depend on the time available for counter actions. If this time is short so that automatic actions are necessary the German safety criteria for nuclear power plants (Criterion 6.1) require two physically diverse signals to be monitored. One fairly obvious possibility of leak detection is to monitor process parameters (pressure, flow). As a diverse signal physical parameters outside the process may be employed: pressure transients temperature, humidity are principally suitable. In practical application, however, it is difficult to predict these parameters by way of calculation in order to establish the required set-point of the monitoring system. Experimental determination is possible only in special cases. A study of several ways of diverse leak detection methods leads to the very promising acoustic method. We investigated experimentally the feasibility of monitoring the sound created by a leakage. Air borne sound as well as body borne sound was analyzed

  10. Standard practice for leaks using ultrasonics

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 Practice A, Pressurization—This practice covers procedures for calibration of ultrasonic instruments, location, and estimated measurements of gas leakage to atmosphere by the airborne ultrasonic technique. 1.2 In general practice this should be limited to leaks detected by two classifications of instruments, Class I and Class II. Class I instruments should have a minimum detectable leak rate of 6.7 × 10−7 mol/s (1.5 × 10−2 std. cm3/s at 0°C) or more for the pressure method of gas leakage to atmosphere. Class II instruments should have a minimal detectable leak rate of 6.7 × 10−6 mol/s (1.5 × 10−1 std. cm3/s at 0°C) or more for the pressure method of gas leakage to atmosphere. Refer to Guide E432 for additional information. 1.3 Practice B, Ultrasonic Transmitter—For object under test not capable of being pressurized but capable of having ultrasonic tone placed/injected into the test area to act as an ultrasonic leak trace source. 1.3.1 This practice is limited to leaks producing leakage o...

  11. An Evaluation of the Acoustic Signal processing Techniques for Sodium-Water Reaction Detection in KALIMER-600

    International Nuclear Information System (INIS)

    Hur, Seop; Seong, S. H.; Kim, T. J.; Kim, S. O.; Lee, M. K.

    2005-02-01

    KALIMER-600 is a pool type fast breeder reactor using liquid sodium as a coolant. Although it has the several advantages such as long-term fuel cycle and enhanced safety concepts, it is possible to leak the secondary side water/steam into sodium boundary. This event could make the plant abnormal condition. One of the major design issues in KALIMER-600 is, therefore, to develop the system which can early detect the sodium-water reaction to protect the sodium-water reaction event. After evaluating the various signal processing techniques for passive acoustic leak detection, we have proposed the early leak detection logics. the signal processing techniques for evaluation were the spectral estimation using the linear modeling, the estimation error of linear modeling, the system adaptation rate using an adaptive signal processing, and the background noise cancellation using adaptive and fixed filtering. As the analysis results regarding the stationary and the cross-correlation of leak signals and background noises, the two signal systems met a wide-dense stationary process and there was only the week cross correlation relationship between two signals. It is ,therefore, possible to use the linear/harmonic modeling of signal systems, and the leak signal in sensor outputs can be discriminated. As the results of the evaluation of the various spectral estimation methods, the spectral estimation method based on autoregressive modeling was more practical comparing with other methods in the sodium-water reaction detection. The passive acoustic leak detection logics were suggested based on above evaluations. the logics consist of 3 levels; transient identification, leak determination and leak symptom identification. The simulation results using sodium-water reaction signals showed that it was possible to determine the leak at above -3dB of SNR, while between -3 dB and -10 dB of SNR the logics determined the leak symptom identification. The detection sensitivity can be enhanced

  12. Designing a reliable leak bio-detection system for natural gas pipelines.

    Science.gov (United States)

    Batzias, F A; Siontorou, C G; Spanidis, P-M P

    2011-02-15

    Monitoring of natural gas (NG) pipelines is an important task for economical/safety operation, loss prevention and environmental protection. Timely and reliable leak detection of gas pipeline, therefore, plays a key role in the overall integrity management for the pipeline system. Owing to the various limitations of the currently available techniques and the surveillance area that needs to be covered, the research on new detector systems is still thriving. Biosensors are worldwide considered as a niche technology in the environmental market, since they afford the desired detector capabilities at low cost, provided they have been properly designed/developed and rationally placed/networked/maintained by the aid of operational research techniques. This paper addresses NG leakage surveillance through a robust cooperative/synergistic scheme between biosensors and conventional detector systems; the network is validated in situ and optimized in order to provide reliable information at the required granularity level. The proposed scheme is substantiated through a knowledge based approach and relies on Fuzzy Multicriteria Analysis (FMCA), for selecting the best biosensor design that suits both, the target analyte and the operational micro-environment. This approach is illustrated in the design of leak surveying over a pipeline network in Greece. Copyright © 2010 Elsevier B.V. All rights reserved.

  13. Results of Tank-Leak Detection Demonstration Using Geophysical Techniques at the Hanford Mock Tank Site-Fiscal Year 2001

    Energy Technology Data Exchange (ETDEWEB)

    Barnett, D BRENT.; Gee, Glendon W.; Sweeney, Mark D.

    2002-03-01

    During July and August of 2001, Pacific Northwest National Laboratory (PNNL), hosted researchers from Lawrence Livermore and Lawrence Berkeley National laboratories, and a private contractor, HydroGEOPHYSICS, Inc., for deployment of the following five geophysical leak-detection technologies at the Hanford Site Mock Tank in a Tank Leak Detection Demonstration (TLDD): (1) Electrical Resistivity Tomography (ERT); (2) Cross-Borehole Electromagnetic Induction (CEMI); (3) High-Resolution Resistivity (HRR); (4) Cross-Borehole Radar (XBR); and (5) Cross-Borehole Seismic Tomography (XBS). Under a ''Tri-party Agreement'' with Federal and state regulators, the U.S. Department of Energy will remove wastes from single-shell tanks (SSTs) and other miscellaneous underground tanks for storage in the double-shell tank system. Waste retrieval methods are being considered that use very little, if any, liquid to dislodge, mobilize, and remove the wastes. As additional assurance of protection of the vadose zone beneath the SSTs, tank wastes and tank conditions may be aggressively monitored during retrieval operations by methods that are deployed outside the SSTs in the vadose zone.

  14. Acoustic Leak Detection under Micro and Small Water Steam Leaks into Sodium for a Protection of the SFR Steam Generator

    International Nuclear Information System (INIS)

    Kim, Tae-Joon; Jeong, Ji-Young; Kim, Jong-Man; Kim, Byung-Ho; Hahn, Do-Hee; Yugay, Valeriy S.

    2008-01-01

    The results of an experimental study of water in a sodium leak noise spectrum formation related with a leak noise attenuation and absorption, and at various rates of water into a sodium leak, smaller than 1.0 g/s, are presented. We focused on studying the micro leak dynamics with an increasing rate of water into sodium owing to a self-development from 0.005 till 0.27 g/s. Conditions and ranges for the existence of bubbling and jetting modes in a water steam outflow into circulating sodium through an injector device, for simulating a defect in a wall of a heat-transmitting tube of a sodium water steam generator were determined. On the basis of the experimental leak noise data the simple dependency of an acoustic signal level from the rate of a micro and small leak at different frequency bands is presented to understand the principal analysis for the development of an acoustic leak detection methodology used in a K- 600 steam generator, with the operational experiences for the noise analysis and measurements in BN-600

  15. AIRBORNE, OPTICAL REMOTE SENSNG OF METHANE AND ETHANE FOR NATURAL GAS PIPELINE LEAK DETECTION

    Energy Technology Data Exchange (ETDEWEB)

    Jerry Myers

    2005-04-15

    Ophir Corporation was awarded a contract by the U. S. Department of Energy, National Energy Technology Laboratory under the Project Title ''Airborne, Optical Remote Sensing of Methane and Ethane for Natural Gas Pipeline Leak Detection'' on October 14, 2002. The scope of the work involved designing and developing an airborne, optical remote sensor capable of sensing methane and, if possible, ethane for the detection of natural gas pipeline leaks. Flight testing using a custom dual wavelength, high power fiber amplifier was initiated in February 2005. Ophir successfully demonstrated the airborne system, showing that it was capable of discerning small amounts of methane from a simulated pipeline leak. Leak rates as low as 150 standard cubic feet per hour (scf/h) were detected by the airborne sensor.

  16. Calibration of a leak detection spectrometer; Calibration d'un spectrometre detecteur de fuites

    Energy Technology Data Exchange (ETDEWEB)

    Geller, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    This paper describes a study of the possible methods for calibrating a leak detection spectrometer, and the estimation of outputs from the leaks is considered. With this in mind the question of sensitivity of leak detection is tackled on a very general level; first the sensitivity of the isolated instrument is determined, and then the sensitivity of an instrument connected to an installation where leaks may be suspected. Finally, practical solutions are proposed. (author) [French] Dans cet article, nous etudions les methodes possibles de calibration d'un spectrometre detecteur de fuites et nous envisageons l'evaluation des debits de fuites trouves. Pour cela, nous abordons la notion de sensibilite de la detection de fuite sur un plan tres general; d'abord nous determinons la sensibilite de l'appareil isole, ensuite la sensibilite d'un appareil connecte sur une installation ou l'on cherche les fuites. Enfin, nous preconisons des solutions pratiques. (auteur)

  17. Pipe fracture evaluations for leak-rate detection: Probabilistic models

    International Nuclear Information System (INIS)

    Rahman, S.; Wilkowski, G.; Ghadiali, N.

    1993-01-01

    This is the second in series of three papers generated from studies on nuclear pipe fracture evaluations for leak-rate detection. This paper focuses on the development of novel probabilistic models for stochastic performance evaluation of degraded nuclear piping systems. It was accomplished here in three distinct stages. First, a statistical analysis was conducted to characterize various input variables for thermo-hydraulic analysis and elastic-plastic fracture mechanics, such as material properties of pipe, crack morphology variables, and location of cracks found in nuclear piping. Second, a new stochastic model was developed to evaluate performance of degraded piping systems. It is based on accurate deterministic models for thermo-hydraulic and fracture mechanics analyses described in the first paper, statistical characterization of various input variables, and state-of-the-art methods of modem structural reliability theory. From this model. the conditional probability of failure as a function of leak-rate detection capability of the piping systems can be predicted. Third, a numerical example was presented to illustrate the proposed model for piping reliability analyses. Results clearly showed that the model provides satisfactory estimates of conditional failure probability with much less computational effort when compared with those obtained from Monte Carlo simulation. The probabilistic model developed in this paper will be applied to various piping in boiling water reactor and pressurized water reactor plants for leak-rate detection applications

  18. Acoustic leak detection at complicated geometrical structures using fuzzy logic and neural networks

    International Nuclear Information System (INIS)

    Hessel, G.; Schmitt, W.; Weiss, F.P.

    1993-10-01

    An acoustic method based on pattern recognition is being developed. During the learning phase, the localization classifier is trained with sound patterns that are generated with simulated leaks at all locations endangered by leak. The patterns are extracted from the signals of an appropriate sensor array. After training unknown leak positions can be recognized through comparison with the training patterns. The experimental part is performed at an acoustic 1:3 model of the reactor vessel and head and at an original VVER-440 reactor in the former NPP Greifswald. The leaks were simulated at the vessel head using mobile sound sources driven either by compressed air, a piezoelectric transmitter or by a thin metal blade excited through a jet of compressed air. The sound patterns of the simulated leaks are simultaneously detected with an AE-sensor array and with high frequency microphones measuring structure-borne sound and airborne sound, respectively. Pattern classifiers based on Fuzzy Pattern Classification (FPC) and Artificial Neural Networks (ANN) are currently tested for validation of the acoustic emission-sensor array (FPC), leak localization via structure-borne sound (FPC) and the leak localization using microphones (ANN). The initial results show the used classifiers principally to be capable of detecting and locating leaks, but they also show that further investigations are necessary to develop a reliable method applicable at NPPs. (orig./HP)

  19. Leak detection device for reactor coolant

    International Nuclear Information System (INIS)

    Oshima, Koichiro.

    1990-01-01

    In a light water cooled reactor, if reactor coolants are leaked from pipelines in a pipeline chamber, activated products (N-16) are diffused together to an atmosphere in the pipeline chamber. N-16 is sucked from an extracting tube which is always sucking the atmosphere in the pipeline chamber to a sucking blower. Then, β-rays released from N-16 are monitored by a radiation monitor in a measuring chamber which is radiation-shielded from the pipeline chamber. Accordingly, since the radiation monitor can detect even slight leakage, the slight leakage of reactor coolants in the pipelines can be detected at an early stage. (I.N.)

  20. Method for fuel element leak detection in pressurized water reactors

    International Nuclear Information System (INIS)

    Kunze, U.

    1983-01-01

    The method is aimed at detecting fuel element leaks during reactor operation. It is based on neutron flux measurements at many points in the core, using at least two detectors at a time. The detectors must be arranged in the direction of the coolant flow. Values obtained from periodic measurements are compared with threshold values. The location of fuel element leaks is determined from those values exceeding the threshold of individual detectors

  1. Dual-energy CT myelography on detection of spontaneous spinal cerebrospinal fluid leaks: initial study

    International Nuclear Information System (INIS)

    Zhang Qiaowei; Wang Dan; Zhang Jinhua; Wang Jin; Zhang Shizheng

    2011-01-01

    Objective: To assess the value of dual-energy computed tomography myelography (CTM) on detecting leaks of cerebrospinal fluid (CSF) in patients with spontaneous intracranial hypotension (SIH). Methods: Six patients with SIH underwent spinal CTM on a 2nd generation dual-source CT with tube voltage set at 100 and 140 kVp (with tin filter). The virtual non-contrast (VNC) and iodine map images were calculated from dual-energy images. The average weighted (AW) CTM images were mixed from two kVp images with mix factor of 0.5. Two radiologists evaluated CSF leak using two sets of images respectively: VNC + iodine map images and AW-CTM images. The results from two reading methods were compared. The level of CSF leaks along the nerve roots, C1-2 retrospinal CSF collections, epidural CSF collections and spinal epidural venous plexus were marked. The consensus about leak sites and CSF collections was made by two radiologists in the third session. Kappa statistics were used to measure the agreement between the two methods. Results: Forty-one leaks were detected using VNC + iodine map images. Forty-three leaks were detected on AW images. The agreement between two methods was excellent (Kappa = 0.997, P<0.01). There were no differences in the detection of C1-2 retrospinal CSF collections (n=2), epidural CSF collections (n=3) or spinal epidural venous plexus (n=1). VNC and iodine map images demonstrated superior visual effects than AW images. Conclusion: Dual-energy CTM can be used to diagnose spontaneous spinal cerebrospinal fluid leaks in SIH patient, (authors)

  2. Temperature monitoring and leak detection in sodium circuits of FBR using Raman distributed fiber optic sensor

    International Nuclear Information System (INIS)

    Kasinathan, M.; Murali, N.; Sosamma, S.; Babu Rao, C.; Kumar, Anish; Purnachandra Rao, B.; Jayakumar, T.

    2013-01-01

    This paper discusses the fiber optic temperature sensor based leak detection in the coolant circuits of fast breeder reactor. These sensors measure the temperature based on spontaneous Raman scattering principle and is not influenced by the electromagnetic interference. Various experiments were conducted to evaluate the performance of the fiber optic sensor based leak detection using Raman distributed Temperature Sensor (RDTS). This paper also deals with the details of fiber optic sensor type leak detector layout for the coolant circuit of FBR, performance requirement of leak detection system, description of the test facility, experimental procedure and test results of various experiments conducted. (author)

  3. A Fiber-Optic Sensor for Leak Detection in a Space Environment

    Science.gov (United States)

    Sinko, John E.; Korman, Valentin; Hendrickson, Adam; Polzin, Kurt A.

    2009-01-01

    A miniature fiber-optic, laser-based, interferometric leak detector is presented for application as a means to detect on-orbit gas leaks. The sensor employs a fiber-coupled modified Michelson interferometer to detect gas leaks by measuring an increase in gas density in the sensing region. Monitoring changes in the fringe pattern output by the interferometer allows for direct measurement of the gas density in the sensing region and, under the assumption of an equation of state, this can be used to obtain a pressure measurement. Measurements obtained over a pressure range from 20 mtorr to 760 torr using a prototypical interferometer on working gases of air, nitrogen, argon, and helium generally exhibit agreement with a theoretical prediction of the pressure increase required before an interference fringe completely moves over the detector. Additional measurements performed on various gases demonstrate the range of detectable species, measuring sub-torr pressure changes in the process. A high-fidelity measurement places the ultimate pressure resolution for this particular sensor configuration in the 10 mtorr range. Time-resolved data prove the capability of this sensor to detect fast gas flow phenomena associated with transients and pressure waves.

  4. T Plant secondary containment and leak detection upgrades

    International Nuclear Information System (INIS)

    Carlson, T.A.

    1995-01-01

    The W-259 project will provide upgrades to the 2706-T/TA Facility to comply with Federal and State of Washington environmental regulations for secondary containment and leak detection. The project provides decontamination activities supporting the environmental restoration mission and waste management operations on the Hanford Site

  5. Field Demonstration of Innovative Condition Assessment Technologies for Water Mains: Leak Detection and Location

    Science.gov (United States)

    Three leak detection/location technologies were demonstrated on a 76-year-old, 2,057-ft-long portion of a cement-lined, 24-in. cast iron water main in Louisville, KY. This activity was part of a series of field demonstrations of innovative leak detection/location and condition a...

  6. COST AND PERFORMANCE REPORT: INNOVATIVE ACOUSTIC SENSOR TECHNOLOGIES FOR LEAK DETECTION IN CHALLENGING PIPE TYPES

    Science.gov (United States)

    2016-12-30

    to limit the drawdown of local water supplies . Implementation of improved leak detection technologies and the timely repair of water mains will...functions and to limit the drawdown of local water supplies . DoD installations lose significant amounts of water through leaking pipe systems that are near... Water Supply Practices M36: Water Audits and Loss Control Programs (2009), leak detection surveys should be conducted every three years. Therefore, it

  7. Fabrication of ultra-sensitive leak detection standards

    International Nuclear Information System (INIS)

    Winkelman, C.R.

    1980-01-01

    The primary difficulty with flow rate measurements below 10 -10 standard cubic centimeters per second (std. cc/sec) is that there are no commercially available standards. The requirements, however, dictate that the problem of design and construction of a qualifiable standard in the ultra-sensitive range had to be solved. There are a number of leak types which were considered - capillary leaks, orifice leaks, and the pore type leaks, among others. The capillary leak was not used because of the cracking or sorting effects that are common to this type leak. For example, a gas blend flowing through a capillary leak will result in the lighter gases passing through the leak first. The difficulty of fabricating the proper hole size in relation to the flow rate requirements ruled out the orifice type leak. The choice was the pore type leak which utilizes the basic concept of a stainless steel knife edge driven into a fixed section composed of stainless steel with a gold over-lay and maintained under force

  8. Geophysical techniques in detection to river embankments - A case study: To locate sites of potential leaks using surface-wave and electrical methods

    Science.gov (United States)

    Chen, C.; Liu, J.; Xu, S.; Xia, J.; ,

    2004-01-01

    Geophysical technologies are very effective in environmental, engineering and groundwater applications. Parameters of delineating nature of near-surface materials such as compressional-wave velocity, shear-wave velocity can be obtained using shallow seismic methods. Electric methods are primary approaches for investigating groundwater and detecting leakage. Both of methods are applied to detect embankment in hope of obtaining evidences of the strength and moisture inside the body. A technological experiment has done for detecting and discovering the hidden troubles in the embankment of Yangtze River, Songzi, Hubei, China in 2003. Surface-wave and DC multi-channel array resistivity sounding techniques were used to detect hidden trouble inside and under dike like pipe-seeps. This paper discusses the exploration strategy and the effect of geological characteristics. A practical approach of combining seismic and electric resistivity measurements was applied to locate potential pipe-seeps in embankment in the experiment. The method presents a potential leak factor based on the shear-wave velocity and the resistivity of the medium to evaluate anomalies. An anomaly found in a segment of embankment detected was verified, where occurred a pipe-seep during the 98' flooding.

  9. Natural gas pipeline leak detector based on NIR diode laser absorption spectroscopy.

    Science.gov (United States)

    Gao, Xiaoming; Fan, Hong; Huang, Teng; Wang, Xia; Bao, Jian; Li, Xiaoyun; Huang, Wei; Zhang, Weijun

    2006-09-01

    The paper reports on the development of an integrated natural gas pipeline leak detector based on diode laser absorption spectroscopy. The detector transmits a 1.653 microm DFB diode laser with 10 mW and detects a fraction of the backscatter reflected from the topographic targets. To eliminate the effect of topographic scatter targets, a ratio detection technique was used. Wavelength modulation and harmonic detection were used to improve the detection sensitivity. The experimental detection limit is 50 ppmm, remote detection for a distance up to 20 m away topographic scatter target is demonstrated. Using a known simulative leak pipe, minimum detectable pipe leak flux is less than 10 ml/min.

  10. Automated Leak Detection Of Buried Tanks Using Geophysical Methods At The Hanford Nuclear Site

    International Nuclear Information System (INIS)

    Calendine, S.; Schofield, J.S.; Levitt, M.T.; Fink, J.B.; Rucker, D.F.

    2011-01-01

    At the Hanford Nuclear Site in Washington State, the Department of Energy oversees the containment, treatment, and retrieval of liquid high-level radioactive waste. Much of the waste is stored in single-shelled tanks (SSTs) built between 1943 and 1964. Currently, the waste is being retrieved from the SSTs and transferred into newer double-shelled tanks (DSTs) for temporary storage before final treatment. Monitoring the tanks during the retrieval process is critical to identifying leaks. An electrically-based geophysics monitoring program for leak detection and monitoring (LDM) has been successfully deployed on several SSTs at the Hanford site since 2004. The monitoring program takes advantage of changes in contact resistance that will occur when conductive tank liquid leaks into the soil. During monitoring, electrical current is transmitted on a number of different electrode types (e.g., steel cased wells and surface electrodes) while voltages are measured on all other electrodes, including the tanks. Data acquisition hardware and software allow for continuous real-time monitoring of the received voltages and the leak assessment is conducted through a time-series data analysis. The specific hardware and software combination creates a highly sensitive method of leak detection, complementing existing drywell logging as a means to detect and quantify leaks. Working in an industrial environment such as the Hanford site presents many challenges for electrical monitoring: cathodic protection, grounded electrical infrastructure, lightning strikes, diurnal and seasonal temperature trends, and precipitation, all of which create a complex environment for leak detection. In this discussion we present examples of challenges and solutions to working in the tank farms of the Hanford site.

  11. Hierarchical Leak Detection and Localization Method in Natural Gas Pipeline Monitoring Sensor Networks

    Science.gov (United States)

    Wan, Jiangwen; Yu, Yang; Wu, Yinfeng; Feng, Renjian; Yu, Ning

    2012-01-01

    In light of the problems of low recognition efficiency, high false rates and poor localization accuracy in traditional pipeline security detection technology, this paper proposes a type of hierarchical leak detection and localization method for use in natural gas pipeline monitoring sensor networks. In the signal preprocessing phase, original monitoring signals are dealt with by wavelet transform technology to extract the single mode signals as well as characteristic parameters. In the initial recognition phase, a multi-classifier model based on SVM is constructed and characteristic parameters are sent as input vectors to the multi-classifier for initial recognition. In the final decision phase, an improved evidence combination rule is designed to integrate initial recognition results for final decisions. Furthermore, a weighted average localization algorithm based on time difference of arrival is introduced for determining the leak point’s position. Experimental results illustrate that this hierarchical pipeline leak detection and localization method could effectively improve the accuracy of the leak point localization and reduce the undetected rate as well as false alarm rate. PMID:22368464

  12. Hierarchical leak detection and localization method in natural gas pipeline monitoring sensor networks.

    Science.gov (United States)

    Wan, Jiangwen; Yu, Yang; Wu, Yinfeng; Feng, Renjian; Yu, Ning

    2012-01-01

    In light of the problems of low recognition efficiency, high false rates and poor localization accuracy in traditional pipeline security detection technology, this paper proposes a type of hierarchical leak detection and localization method for use in natural gas pipeline monitoring sensor networks. In the signal preprocessing phase, original monitoring signals are dealt with by wavelet transform technology to extract the single mode signals as well as characteristic parameters. In the initial recognition phase, a multi-classifier model based on SVM is constructed and characteristic parameters are sent as input vectors to the multi-classifier for initial recognition. In the final decision phase, an improved evidence combination rule is designed to integrate initial recognition results for final decisions. Furthermore, a weighted average localization algorithm based on time difference of arrival is introduced for determining the leak point's position. Experimental results illustrate that this hierarchical pipeline leak detection and localization method could effectively improve the accuracy of the leak point localization and reduce the undetected rate as well as false alarm rate.

  13. Hierarchical Leak Detection and Localization Method in Natural Gas Pipeline Monitoring Sensor Networks

    Directory of Open Access Journals (Sweden)

    Ning Yu

    2011-12-01

    Full Text Available In light of the problems of low recognition efficiency, high false rates and poor localization accuracy in traditional pipeline security detection technology, this paper proposes a type of hierarchical leak detection and localization method for use in natural gas pipeline monitoring sensor networks. In the signal preprocessing phase, original monitoring signals are dealt with by wavelet transform technology to extract the single mode signals as well as characteristic parameters. In the initial recognition phase, a multi-classifier model based on SVM is constructed and characteristic parameters are sent as input vectors to the multi-classifier for initial recognition. In the final decision phase, an improved evidence combination rule is designed to integrate initial recognition results for final decisions. Furthermore, a weighted average localization algorithm based on time difference of arrival is introduced for determining the leak point’s position. Experimental results illustrate that this hierarchical pipeline leak detection and localization method could effectively improve the accuracy of the leak point localization and reduce the undetected rate as well as false alarm rate.

  14. New methods for leaks detection and localisation using acoustic emission

    International Nuclear Information System (INIS)

    Boulanger, P.

    1993-01-01

    Real time monitoring of Pressurized Water nuclear Reactor secondary coolant system tends to integrate digital processing machines. In this context, the method of acoustic emission seems to exhibit good performances. Its principle is based on passive listening of noises emitted by local micro-displacements inside a material under stress which propagate as elastic waves. The lack of a priori knowledge on leak signals leads us to go deeper into understanding flow induced noise generation. Our studies are conducted using a simple leak model depending on the geometry and the king of flow inside the slit. Detection and localization problems are formulated according to the maximum likelihood principle. For detection, the methods using a indicator of similarity (correlation, higher order correlation) seems to give better results than classical ones (rms value, envelope, filter banks). For leaks location, a large panel of classical (generalized inter-correlation) and innovative (convolution, adaptative, higher order statistics) methods of time delay estimation are presented. The last part deals with the applications of higher order statistics. The analysis of higher order estimators of a non linear non Gaussian stochastic process family, the improvement of non linear prediction performances and the optimal-order choice problem are addressed in simple analytic cases. At last, possible applications to leak signals analysis are pointed out. (authors).264 refs., 7 annexes

  15. CANDU pressure tube leak detection by annulus gas dew point measurement. A critical review

    International Nuclear Information System (INIS)

    Greening, F.R.

    2017-01-01

    In the event of a pressure tube leak from a small through-wall crack during CANDU reactor operations, there is a regulatory requirement - referred to as Leak Before Break (LBB) - for the licensee to demonstrate that there will be sufficient time for the leak to be detected and the reactor shut down before the crack grows to the critical size for fast-uncontrolled rupture. In all currently operating CANDU reactors, worldwide, this LBB requirement is met via continuous dew point measurements of the CO_2 gas circulating in the reactor's Annulus Gas System (AGS). In this paper the historical development and current status of this leak detection capability is reviewed and the use of moisture injection tests as a verification procedure is critiqued. It is concluded that these tests do not represent AGS conditions that are to be expected in the event of a real pressure tube leak.

  16. CANDU pressure tube leak detection by annulus gas dew point measurement. A critical review

    Energy Technology Data Exchange (ETDEWEB)

    Greening, F.R. [CTS-NA, Tiverton, ON (Canada)

    2017-03-15

    In the event of a pressure tube leak from a small through-wall crack during CANDU reactor operations, there is a regulatory requirement - referred to as Leak Before Break (LBB) - for the licensee to demonstrate that there will be sufficient time for the leak to be detected and the reactor shut down before the crack grows to the critical size for fast-uncontrolled rupture. In all currently operating CANDU reactors, worldwide, this LBB requirement is met via continuous dew point measurements of the CO{sub 2} gas circulating in the reactor's Annulus Gas System (AGS). In this paper the historical development and current status of this leak detection capability is reviewed and the use of moisture injection tests as a verification procedure is critiqued. It is concluded that these tests do not represent AGS conditions that are to be expected in the event of a real pressure tube leak.

  17. Detection of leak-defective fuel rods using the circumferential Lamb waves excited by the resonance backscattering of ultrasonic pulses

    International Nuclear Information System (INIS)

    Choi, M.S.; Yang, M.S.; Kim, H.C.

    1992-01-01

    A new ultrasonic technique for detecting the infiltrated water in leaked fuel rods is developed. Propagation characteristics of the circumferential Lamb waves in the cladding tubes are estimated by the resonance scattering theory. The Lamb waves are excited by the resonance backscattering of ultrasonic pulses. In sound fuel rods, the existence of the Lamb waves is revealed by a series of periodic echoes. In leaked fuel rods, however, the Lamb waves are perturbed strongly by the scattered waves from the surface of fuel pellets, thus the periodic echoes are not observed. (author)

  18. Hermetic Seal Leak Detection Apparatus with Variable Size Test Chamber

    Science.gov (United States)

    Kelley, Anthony R. (Inventor)

    2015-01-01

    The present invention is a versatile hermetic seal leak detection apparatus for testing hermetically sealed containers and devices for leaks without the need to create a custom or specially manufactured testing chamber conforming to the dimensions of the specific object under test. The size of the testing chamber may be mechanically adjusted by the novel use of bellows to reduce and optimize the amount of gas space in a test chamber which surrounds the hermetically sealed object under test. The present invention allows the size of the test chamber to be selectively adjusted during testing to provide an optimum test chamber gas space. The present invention may be further adapted to isolate and test specific portions of the hermetically sealed object under test for leaks.

  19. Tube leak detection device and acoustic sensor support device for moisture separating heater

    International Nuclear Information System (INIS)

    Miyabe, Keisuke; Kobayashi, Takefumi.

    1995-01-01

    The device of the present invention comprises an acoustic sensor which detects leak sounds when leak occurs in a heating tube of a moisture separating heater incorporated into a plant, a threshold value memory and switching mechanism containing each of threshold values on every power of a plant, and a leak judging mechanism for judging presence or absence of leaks by comparing a selected threshold value and signals given from the acoustic sensor. Background noises changing currently during operation of a steam turbine plant are compared with a threshold value greater than the background noises in the leak judging mechanism, and they are judged as 'no leak' so as not to recognize them as 'presence of tube leak'. Output values from the acoustic sensor are obtained on every frequency component, and standard frequency spectra are selected by turbine load corresponding signals using a standard spectra memory and switching mechanism. They are sent to a leak judging mechanism to analyze the acoustic signals using a frequency analyzer and compare them with the frequency spectral thereby judging leaks. (N.H.)

  20. Detection of a leaking boron-carbide control rod in a TRIGA Mark I reactor

    Energy Technology Data Exchange (ETDEWEB)

    Blotcky, A J; Arsenault, L J [General Medical Research, Veterans Administration Hospital, Omaha (United States)

    1974-07-01

    During a routine quarterly inspection of the boron-carbide control rods of the Omaha Veterans Administration Hospital 18 kW Triga Mark I reactor, a pin hole leak was detected approximately 3 mm from the chamfered edge. The leak was found by observing bubbles when the rod was withdrawn from the reactor tank for visual observation, and could not be seen with the naked eye. This suggests that pin hole leaks could occur and not be visually detected in control rods and fuel elements examined underwater. A review of the rod calibrations showed that the leak had not caused a loss in rod worth. Slides will be presented showing the bubbles observed during the inspection, together with an unmagnified and magnified view of the pin hole. (author)

  1. Detection of a leaking boron-carbide control rod in a TRIGA Mark I reactor

    International Nuclear Information System (INIS)

    Blotcky, A.J.; Arsenault, L.J.

    1974-01-01

    During a routine quarterly inspection of the boron-carbide control rods of the Omaha Veterans Administration Hospital 18 kW Triga Mark I reactor, a pin hole leak was detected approximately 3 mm from the chamfered edge. The leak was found by observing bubbles when the rod was withdrawn from the reactor tank for visual observation, and could not be seen with the naked eye. This suggests that pin hole leaks could occur and not be visually detected in control rods and fuel elements examined underwater. A review of the rod calibrations showed that the leak had not caused a loss in rod worth. Slides will be presented showing the bubbles observed during the inspection, together with an unmagnified and magnified view of the pin hole. (author)

  2. Investigation of Natural Gas Fugitive Leak Detection Using an Unmanned Aerial Vehicle

    Science.gov (United States)

    Yang, S.; Talbot, R. W.; Frish, M. B.; Golston, L.; Aubut, N. F.; Zondlo, M. A.

    2017-12-01

    The U.S is now the world's largest natural gas producer, of which methane (CH4) is the main component. About 2% of the CH4 is lost through fugitive leaks. This research is under the DOE Methane Observation Networks with Innovative Technology to Obtain Reductions (MONITOR) program of ARPA-E. Our sentry measurement system is composed of four state-of-the-art technologies centered around the RMLDTM (Remote Methane Leak Detector). An open path RMLDTM measures column-integrated CH4 concentration that incorporates fluctuations in the vertical CH4 distribution. Based on Backscatter Tunable Diode Laser Absorption Spectroscopy and Small Unmanned Aerial Vehicles, the sentry system can autonomously, consistently and cost-effectively monitor and quantify CH4 leakage from sites associated with natural gas production. This system provides an advanced capability in detecting leaks at hard-to-access sites (e.g., wellheads) compared to traditional manual methods. Automated leak detecting and reporting algorithms combined with wireless data link implement real-time leak information reporting. Early data were gathered to set up and test the prototype system, and to optimize the leak localization and calculation strategies. The flight pattern is based on a raster scan which can generate interpolated CH4 concentration maps. The localization and quantification algorithms can be derived from the plume images combined with wind vectors. Currently, the accuracy of localization algorithm can reach 2 m and the calculation algorithm has a factor of 2 accuracy. This study places particular emphasis on flux quantification. The data collected at Colorado and Houston test fields were processed, and the correlation between flux and other parameters analyzed. Higher wind speeds and lower wind variation are preferred to optimize flux estimation. Eventually, this system will supply an enhanced detection capability to significantly reduce fugitive CH4 emissions in the natural gas industry.

  3. Leak detection of KNI seals

    International Nuclear Information System (INIS)

    Baranyai, G.; Peter, A.; Windberg, P.

    1990-03-01

    In Unit 3 and 4 of the Paks Nuclear Power Plant, Hungary, KNI type seals are used as lead-throughs with conical nickel sealing rings. Their failure can be critical for the operation of the reactor. An Acoustical Leak Detection System (ALDS) was constructed and tested for the operational testing of the seals. Some individual papers are presented in this collection on the calibration and testing of the ALDS intended to be placed on the top of the reactor vessels. The papers include simulation measurements of Unit 3 of NPP, laboratory experiments, evaluation of measurements, and further development needs with the ALDS. (R.P.) 50 figs.; 19 tabs

  4. Powers of detection : technology companies vie to capture leak survey business for natural gas pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Byfield, M.

    2005-09-01

    ITT Industries Inc., Physical Sciences Inc., and LaSen Inc. are 3 American companies leading the way to find more efficient methods for identifying leaks from natural gas pipelines. Edmonton-based Synodon Inc. has recently joined the leaders with its newly developed and more sensitive equipment that it hopes to have on the market by the summer of 2006. Leak detection technology was first developed in 1993 in response to concerns about the reliability of aging pipeline infrastructure. In addition to safety concerns, there are concerns over global warming. Methane is a potential greenhouse gas and the United states Environmental Protection Agency estimates that 300 billion cubic feet escape into the atmosphere every year from pipeline leaks. The 2002 Pipeline Safety Improvement Bill in the United States stipulates that leak inspections must be conducted up to 4 times per year in densely populated areas. Violators face fines as high as $1 million. In response to the pipeline safety bill, Synodon raised private equity financing to commercialize an airborne leak detection technology stemming from Canada's space program. In the United States, leak detection technologies that appear likely to take 5 to 20 years for commercialization have been been financed by the Department of Energy and the Office of Pipeline Safety. This paper summarized 5 leak detection prototypes, including ITT's Airborne Natural Gas Emission LiDAR (ANGEL) system which targets high-pressure, long-distance pipelines in North America, LaSen's Airborne LiDAR Pipeline Inspection System (ALPIS) based on DIAL Technology, and a hand-held remote methane leak detector developed jointly by Physical Sciences Inc. of Massachusetts and Houston-based Heath Consultants Inc. Synodon claims that hand-held detectors are too slow and that LiDAR systems still aren't reliable for detection of leaks much below 500 scf/h. Synodon's realSens technology may be more difficult to develop, but it detects

  5. Active acoustic leak detection in steam generator units of fast reactors

    International Nuclear Information System (INIS)

    Oriol, L.; Journeau, Ch.

    1996-01-01

    Steam generators (SG) of Fast Reactors can be subject to water leakage into the sodium secondary circuit, causing an exothermic chemical reaction with potential serious damage to plant. Within the framework of the European Fast Reactor project, the CEA has developed an active acoustic detection technique which, when used in parallel with passive acoustic detection, will lead to effective leak detection results in terms of reliability and false alarm rates. Whilst the passive method is based on the increase in acoustic noise generated by the reaction, the active method takes advantage of the acoustic attenuation by the hydrogen bubbles produced. The method has been validated: in water, during laboratory testing at the Centre d'Etudes de Cadarache; in sodium, at the ASB loop at Bensberg (Germany) and at AEA Dounreay (Scotland). Full analysis of the tests carried out on the SG of the Prototype Fast Reactor in 1994 during end-of-life testing should lead to reactor validation on the method. (authors)

  6. Operation of the water-to-sodium leak detection system at the experimental breeder reactor II

    International Nuclear Information System (INIS)

    Osterhout, M.M.

    1978-01-01

    A water-to-sodium leak detection system was installed at the Experimental Breeder Reactor II in April 1975. The system is designed for early detection of steam generator leaks, using hydrogen meters at the sodium outlets of the evaporators and superheaters. The leak detectors operate by measuring the rate of diffusion of hydrogen from the liquid sodium through a nickel membrane into a dynamic vacuum system. The advantages of this detection system are rapid response time, high sensitivity, stability, and reliability. The system was operated on an experimental basis for the first two years. During this period, data were obtained on detector stability, reliability, maintenance needs, computer interface requirements, calibration, and background hydrogen-level fluctuations. A generic defect in the original detectors was also discovered, requiring redesign of the units. When the new units were installed and proven to be reliable, the system was made fully operational. The data from the hydrogen meters are now used as the primary basis for detection of water-to-sodium leaks

  7. Review of nuclear power reactor coolant system leakage events and leak detection requirements

    International Nuclear Information System (INIS)

    Chokshi, N.C.; Srinivasan, M.; Kupperman, D.S.; Krishnaswamy, P.

    2005-01-01

    In response to the vessel head event at the Davis-Besse reactor, the U.S. Nuclear Regulatory Commission (NRC) formed a Lessons Learned Task Force (LLTF). Four action plans were formulated to respond to the recommendations of the LLTF. The action plans involved efforts on barrier integrity, stress corrosion cracking (SCC), operating experience, and inspection and program management. One part of the action plan on barrier integrity was an assessment to identify potential safety benefits from changes in requirements pertaining to leakage in the reactor coolant system (RCS). In this effort, experiments and models were reviewed to identify correlations between crack size, crack-tip-opening displacement (CTOD), and leak rate in the RCS. Sensitivity studies using the Seepage Quantification of Upsets In Reactor Tubes (SQUIRT) code were carried out to correlate crack parameters, such as crack size, with leak rate for various types of crack configurations in RCS components. A database that identifies the leakage source, leakage rate, and resulting actions from RCS leaks discovered in U.S. light water reactors was developed. Humidity monitoring systems for detecting leakage and acoustic emission crack monitoring systems for the detection of crack initiation and growth before a leak occurs were also considered. New approaches to the detection of a leak in the reactor head region by monitoring boric-acid aerosols were also considered. (authors)

  8. Distributed Leak Detection System Using Structure-Borne Noise, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Manned spacecraft are vulnerable to air leaks caused by micrometeoroid and space debris impact. The ability to detect and quickly locate and mitigate a pressure...

  9. Corrosion Evaluation of Tank 40 Leak Detection Box

    Energy Technology Data Exchange (ETDEWEB)

    Mickalonis, J.I.

    1999-07-29

    'Leak detection from the transfer lines in the tank farm has been a concern for many years because of the need to minimize exposure of personnel and contamination of the environment. The leak detection box (LDB) is one line of defense, which must be maintained to meet this objective. The evaluation of a failed LDB was one item from an action plan aimed at minimizing the degradation of LDBs. The Tank 40 LDB, which failed in service, was dug up and shipped to SRTC for evaluation. During a video inspection while in service, this LDB was found to have black tubercles on the interior, which suggested possible microbial involvement. The failure point, however, was believed to have occurred in the drain line from the transfer line jacket. Visual, metallurgical, and biological analyses were performed on the LDB. The analysis results showed that there was not any adverse microbiological growth or significant localized corrosion. The corrosion of the LDB was caused by exposure to aqueous environments and was typical of carbon steel pipes in soil environments.'

  10. Helium leak testing the Westinghouse LCP coil

    International Nuclear Information System (INIS)

    Merritt, P.A.; Attaar, M.H.; Hordubay, T.D.

    1983-01-01

    The tests, equipment, and techniques used to check the Westinghouse LCP coil for coolant flow path integrity and helium leakage are unique in terms of test sensitivity and application. This paper will discuss the various types of helium leak testing done on the LCP coil as it enters different stages of manufacture. The emphasis will be on the degree of test sensitivity achieved under shop conditions, and what equipment, techniques and tooling are required to achieve this sensitivity (5.9 x 10 -8 scc/sec). Other topics that will be discussed are helium flow and pressure drop testing which is used to detect any restrictions in the flow paths, and the LCP final acceptance test which is the final leak test performed on the coil prior to its being sent for testing. The overall allowable leak rate for this coil is 5 x 10 -6 scc/sec. A general evaluation of helium leak testing experience are included

  11. Helium Mass Spectrometer Leak Detection: A Method to Quantify Total Measurement Uncertainty

    Science.gov (United States)

    Mather, Janice L.; Taylor, Shawn C.

    2015-01-01

    In applications where leak rates of components or systems are evaluated against a leak rate requirement, the uncertainty of the measured leak rate must be included in the reported result. However, in the helium mass spectrometer leak detection method, the sensitivity, or resolution, of the instrument is often the only component of the total measurement uncertainty noted when reporting results. To address this shortfall, a measurement uncertainty analysis method was developed that includes the leak detector unit's resolution, repeatability, hysteresis, and drift, along with the uncertainty associated with the calibration standard. In a step-wise process, the method identifies the bias and precision components of the calibration standard, the measurement correction factor (K-factor), and the leak detector unit. Together these individual contributions to error are combined and the total measurement uncertainty is determined using the root-sum-square method. It was found that the precision component contributes more to the total uncertainty than the bias component, but the bias component is not insignificant. For helium mass spectrometer leak rate tests where unit sensitivity alone is not enough, a thorough evaluation of the measurement uncertainty such as the one presented herein should be performed and reported along with the leak rate value.

  12. Dynamic modelling and real-time leak detection for NGL pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Young, B.R.; Svrcek, W.Y. [Calgary Univ., AB (Canada). Dept. of Chemical and Petroleum Engineering; Cooke, J.G.; Daye, R.E. [Rangeland Engineering Ltd., Calgary, AB (Canada)

    2004-07-01

    This paper presented newly developed steady-state and dynamic models commissioned for natural gas liquids (NGL) pipelines near Empress, Alberta. The work demonstrates a unique university-industry collaboration for solving the challenge of reliable pipeline leak detection. The flexible, custom real-time leak detection system was tested on the dynamic simulation. It was successfully used to replace a volume balance system for NGL pipelines at Empress in March 2003. A custom pipeline monitoring system was also developed to integrate with the existing pipeline supervisory control and data acquisition (SCADA) system. Simulation results enabled a change in the control scheme of the pipelines that resulted in less transient operation. The premise of the leak detection system is a rigorous thermodynamics and dynamic mass balance calculation based on real-time information from field flow, pressure and temperature sensors. The application of the system makes it possible to minimize or eliminate false or nuisance alarms, which is critical to the confidence of the monitoring system. The volumetric and mass imbalance formulae permit the system to cross check the calculation and then make important decisions regarding the sounding of alarms. The custom solution offers flexibility for use in a wide variety of conditions and applications. In addition, it is cost effective and locally supported. 8 refs., 4 tabs., 5 figs.

  13. Raman distributed sensor system for temperature monitoring and leak detection in sodium circuits of FBR

    Energy Technology Data Exchange (ETDEWEB)

    Pandian, C.; Kasinathan, M.; Sosamma, S.; Babu Rao, C.; Jayakumar, T.; Murali, N.; Paunikar, V.; Kumar, S.; Rajan, K. K.; Raj, B. [Indira Gandhi Centre for Atomic Research, Kalpakkam (India)

    2009-07-01

    Leak detection in coolant loops of nuclear reactors is critical for the safety and performance of the reactors. The feasibility of using Raman distributed temperature sensor (RDTS) has been studied on a 30 m test loop. Temperature in sodium circuits of fast Breeder Reactor (FBR) exceeds 550 C degrees, gold coated fiber is chosen as sensor fibers. Leak is simulated through an artificial micro fissure integrated in the test loop with provision for controlled leak rate. The results are discussed in the paper. The temperature response of RDTS is compared to the conventional thermocouple and their performance was found comparable. The feasibility of detecting the temperature differential of a controlled leak with RDTS is demonstrated

  14. Location of leaks in pressurized underground pipelines

    International Nuclear Information System (INIS)

    Eckert, E.G.; Maresca, J.W. Jr.

    1993-01-01

    Millions of underground storage tanks (UST) are used to store petroleum and other chemicals. The pressurized underground pipelines associated with USTs containing petroleum motor fuels are typically 2 in. in diameter and 50 to 200 ft in length. These pipelines typically operate at pressures of 20 to 30 psi. Longer lines, with diameters up to 4 in., are found in some high-volume facilities. There are many systems that can be used to detect leaks in pressurized underground pipelines. When a leak is detected, the first step in the remediation process is to find its location. Passive-acoustic measurements, combined with advanced signal-processing techniques, provide a nondestructive method of leak location that is accurate and relatively simple, and that can be applied to a wide variety of pipelines and pipeline products

  15. Assessing the accuracy of TDR-based water leak detection system

    Science.gov (United States)

    Fatemi Aghda, S. M.; GanjaliPour, K.; Nabiollahi, K.

    2018-03-01

    The use of TDR system to detect leakage locations in underground pipes has been developed in recent years. In this system, a bi-wire is installed in parallel with the underground pipes and is considered as a TDR sensor. This approach greatly covers the limitations arisen with using the traditional method of acoustic leak positioning. TDR based leak detection method is relatively accurate when the TDR sensor is in contact with water in just one point. Researchers have been working to improve the accuracy of this method in recent years. In this study, the ability of TDR method was evaluated in terms of the appearance of multi leakage points simultaneously. For this purpose, several laboratory tests were conducted. In these tests in order to simulate leakage points, the TDR sensor was put in contact with water at some points, then the number and the dimension of the simulated leakage points were gradually increased. The results showed that with the increase in the number and dimension of the leakage points, the error rate of the TDR-based water leak detection system increases. The authors tried, according to the results obtained from the laboratory tests, to develop a method to improve the accuracy of the TDR-based leak detection systems. To do that, they defined a few reference points on the TDR sensor. These points were created via increasing the distance between two conductors of TDR sensor and were easily identifiable in the TDR waveform. The tests were repeated again using the TDR sensor having reference points. In order to calculate the exact distance of the leakage point, the authors developed an equation in accordance to the reference points. A comparison between the results obtained from both tests (with and without reference points) showed that using the method and equation developed by the authors can significantly improve the accuracy of positioning the leakage points.

  16. Assessing the accuracy of TDR-based water leak detection system

    Directory of Open Access Journals (Sweden)

    S.M. Fatemi Aghda

    2018-03-01

    Full Text Available The use of TDR system to detect leakage locations in underground pipes has been developed in recent years. In this system, a bi-wire is installed in parallel with the underground pipes and is considered as a TDR sensor. This approach greatly covers the limitations arisen with using the traditional method of acoustic leak positioning. TDR based leak detection method is relatively accurate when the TDR sensor is in contact with water in just one point. Researchers have been working to improve the accuracy of this method in recent years.In this study, the ability of TDR method was evaluated in terms of the appearance of multi leakage points simultaneously. For this purpose, several laboratory tests were conducted. In these tests in order to simulate leakage points, the TDR sensor was put in contact with water at some points, then the number and the dimension of the simulated leakage points were gradually increased. The results showed that with the increase in the number and dimension of the leakage points, the error rate of the TDR-based water leak detection system increases.The authors tried, according to the results obtained from the laboratory tests, to develop a method to improve the accuracy of the TDR-based leak detection systems. To do that, they defined a few reference points on the TDR sensor. These points were created via increasing the distance between two conductors of TDR sensor and were easily identifiable in the TDR waveform. The tests were repeated again using the TDR sensor having reference points. In order to calculate the exact distance of the leakage point, the authors developed an equation in accordance to the reference points. A comparison between the results obtained from both tests (with and without reference points showed that using the method and equation developed by the authors can significantly improve the accuracy of positioning the leakage points. Keywords: Multiple leakage points, TDR, Reference points

  17. Leak detection in the primary reactor coolant piping of nuclear power plant by applying beam-microphone technology

    International Nuclear Information System (INIS)

    Kasai, Yoshimitsu; Shimanskiy, Sergey; Naoi, Yosuke; Kanazawa, Junichi

    2004-01-01

    A microphone leak detection method was applied to the inlet piping of the ATR-prototype reactor, Fugen. Statistical analysis results showed that the cross-correlation method provided the effective results for detection of a small leakage. However, such a technique has limited application due to significant distortion of the signals on the reactor site. As one of the alternative methods, the beam-microphone provides necessary spatial selectivity and its performance is less affected by signal distortion. A prototype of the beam-microphone was developed and then tested at the O-arai Engineering Center of the Japan Nuclear Cycle Development Institute (JNC). On-site testing of the beam-microphone was carried out in the inlet piping room of an RBMK reactor of the Leningrad Nuclear Power Plant (LNPP) in Russia. A leak sound imitator was used to simulate the leakage sound under the leakage flow condition of 1-3 gpm (0.23-0.7 m 3 /h). Analysis showed that signal distortion does not seriously affect the performance of this method, and that sound reflection may result in the appearance of ghost sound sources. The test results showed that the influences of sound reflection and background noise were smaller at the high frequencies where the leakage location could be estimated with an angular accuracy of 5deg which is the range of localization accuracy required for the leak detection system. (author)

  18. 40 CFR 61.243-2 - Alternative standards for valves in VHAP service-skip period leak detection and repair.

    Science.gov (United States)

    2010-07-01

    ... VHAP service-skip period leak detection and repair. 61.243-2 Section 61.243-2 Protection of Environment... AIR POLLUTANTS National Emission Standard for Equipment Leaks (Fugitive Emission Sources) § 61.243-2 Alternative standards for valves in VHAP service—skip period leak detection and repair. (a)(1) An owner or...

  19. Research on pipeline leak detection method based on pressure and dynamic pressure

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Likun; Xiong, Min; Zhao, Jinyun; Wang, Hongchao; Xu, Bin; Yu, DongLiang; Sun, Yi; Cai, Yongjun [RnD center of PetroChina Pipeline Company, Langfang, Hebei, (China)

    2010-07-01

    Pipeline leakages are very frequent and need to be detected as fast as possible to avoid safety and environment issues. Many leakage detection processes have been developed. Acoustic wave methods based on static pressure and dynamic pressure are both used for pipeline leakage detection. This study investigated a new pipeline leak detection method based on joint pressure and dynamic pressure. A dynamic pressure transmitter was designed based on a piezoelectric dynamic pressure sensor. The study showed that the dynamic pressure signal should be used for pipeline leak detection with a quick-change in pipeline internal pressure, while the static pressure signal provides better results with a slow-change of pipeline internal pressure. The in-field results showed that the location error of dynamic pressure is reduced to 80 m with a leakage ratio of 0.6 % pipeline throughput.

  20. Overview of frequency bandwidth determination techniques of useful signal in case of leaks detection by correlation method

    International Nuclear Information System (INIS)

    Faerman, V A; Avramchuk, V S; Luneva, E E

    2014-01-01

    In this paper an overview of useful signal detection methods on the background of intense noise and limits determination methods of useful signal is presented. The following features are considered: peculiarities of usage of correlation analysis, cross-amplitude spectrum, coherence function, cross-phase spectrum, time-frequency correlation function in case of frequency limits determination as well as leaks detection in pipelines. The possibility of using time-frequency correlation function for solving above named issues is described. Time- frequency correlation function provides information about the signals correlation for each of the investigated frequency bands. Data about location of peaks on the surface plot of a time- frequency correlation function allows making an assumption about the spectral composition of useful signal and its frequency boundaries

  1. ALIBABA, an assistance system for the detection of confinement leaks in a PWR reactor

    International Nuclear Information System (INIS)

    Bedier, P.O.; Libmann, M.

    1995-01-01

    The objective of the Crisis Technical Center (CTC) of the French Institute for Nuclear Protection and Safety (IPSN) is to estimates the consequences of a given nuclear accident on the populations and the environment. ALIBABA is a data processing tool available at the CTC and devoted to the detection of confinement leaks in 900 MWe PWR reactors using the activity values measured by the captors of the installation. The heart of this expert system is a structural and functional representation of the different components directly involved in the leak detection (isolating valves, ventilation systems, electric boards etc..). This tool can manage the availability of each component to make qualitative and quantitative balance-sheets. This paper presents the ALIBABA software, an industrial prototype realized with the SPIRAL knowledge base systems generator at the CEA Reactor Studies and Applied Mathematics Service (SERMA) and commercialized by CRIL-Ingenierie Society. It describes the techniques used for the modeling of PWR systems and for the visualization of the survey. The functionality of the man-machine interface is discussed and the means used for the validation of the software are summarized. (J.S.). 6 refs

  2. Experimental results of passive vibro-acoustic leak detection in SFR steam generator mock-up

    International Nuclear Information System (INIS)

    Moriot, J.; Gastaldi, O.; Maxit, L.; Guyader, J-L.; Perisse, J.; Migot, B.

    2013-06-01

    Regarding to GEN 4 context, it is necessary to fulfil the high safety standards for sodium fast reactors (SFR), particularly against water-sodium reaction which may occur in the steam generator units (SGU) in case of leak. This reaction can cause severe damages in the component in a short time. Detecting such a leak by visual in-sodium inspection is impossible because of sodium opacity. Hydrogen detection is then used but the time response of this method can be high in certain operating conditions. Active and passive acoustic leak detection methods were studied before SUPERPHENIX plant shutdown in 1997 to detect a water-into-sodium leak with a short time response. In the context of the new R and D studies for SFR, an innovative passive vibro-acoustic method is developed in the framework of a Ph.D. thesis to match with GEN 4 safety requirements. The method consists in assuming that a small leak emits spherical acoustic waves in a broadband frequency domain, which propagate in the liquid sodium and excite the SGU cylindrical shell. These spatially coherent waves are supposed to be buried by a spatially incoherent background noise. The radial velocities of the shell is measured by an array of accelerometers positioned on the external envelop of the SGU and a beam forming treatment is applied to increase the signal-to-noise ratio (SNR) and to detect and localize the acoustic source. Previous numerical experiments were achieved and promising results were obtained. In this paper, experimental results of the proposed passive vibro-acoustic leak detection are presented. The experiment consists in a cylindrical water-filled steel pipe representing a model of SGU shell without tube bundle. A hydro-phone emitting an acoustic signal is used to simulate an acoustic monopole. Spatially uncorrelated noise or water-flow induced shell vibrations are considered as the background noise. The beam-forming method is applied to vibration signals measured by a linear array of

  3. A New Concept for an Effective Leak Detection and Loclisation in Multiphase Fluid Pipelines

    Directory of Open Access Journals (Sweden)

    Mahmoud Meribout

    2011-02-01

    Full Text Available The aim of this paper is to present a secure wireless sensor network-based infrastructure for fast and accurate detection of eventual leaks that might occur in multiphase pipelines (i.e., pipelines which carry simultaneously more than one fluid. The system is scalable to monitor long distances of pipelines. It consists of a newly designed low cost pipeline set which is composed of an inner pipe that carries the multiphase fluid, surrounded by a second outer pipe that holds the leak detection unit. This latest comprises an air-ultrasonic sensor which continuously senses the presence of the leak. The location of the leak is determined by a bidirectional microphone. Both these sensors are interfaced to a wireless sensor module which performs control, signal processing, and transmission tasks. Hence, the second contribution of the paper is to provide a new secure and reliable communication protocol that takes into consideration the nature of the network in terms of packets patterns and hardware constraints of the communicating nodes. Online tests in a laboratory scale flow loop indicate that the system is capable to accurately determine the location of the leak and its rate (in l/min in fast response time for different scenarios of leaks.

  4. CEGB research on boiler leaks and their detection in service

    International Nuclear Information System (INIS)

    Hayes, D.J.

    1978-01-01

    The penalty in loss of output to an electricity generation organisation as a consequence of failure to deal effectively with small LMFBR boiler leaks would be large. There is therefore a considerable incentive for these organisations to satisfy themselves that proper provisions are made to ensure that both the incidence and the severity of boiler leaks are minimised. In the UK, responsibility for the research, development and design work for this and indeed for most aspects of future nuclear power plant rests with the UKAEA and NPC; nevertheless as a consequence of its 'informed operator' policy the Central Electricity Generating Board has devoted some research effort to this field in recent years. o date, research work has been put in hand with the objective of achieving an understanding of the basic behaviour of boiler leaks. In addition, attention has been given to leak detection by monitoring the sodium for increases in oxygen and hydrogen levels. In both cases leaks into liquid sodium rather than into the gas space have been considered. In the course of the work hydrogen and oxygen meters based on the galvanic cell principle have been constructed and evaluated. The former is a new device which is comparable in performance with hydrogen meters based on the ion pump. The present state of the work is briefly described in this paper

  5. CEGB research on boiler leaks and their detection in service

    Energy Technology Data Exchange (ETDEWEB)

    Hayes, D J [Berkeley Nuclear Laboratories, Berkeley, Gloucestershire (United Kingdom)

    1978-10-01

    The penalty in loss of output to an electricity generation organisation as a consequence of failure to deal effectively with small LMFBR boiler leaks would be large. There is therefore a considerable incentive for these organisations to satisfy themselves that proper provisions are made to ensure that both the incidence and the severity of boiler leaks are minimised. In the UK, responsibility for the research, development and design work for this and indeed for most aspects of future nuclear power plant rests with the UKAEA and NPC; nevertheless as a consequence of its 'informed operator' policy the Central Electricity Generating Board has devoted some research effort to this field in recent years. o date, research work has been put in hand with the objective of achieving an understanding of the basic behaviour of boiler leaks. In addition, attention has been given to leak detection by monitoring the sodium for increases in oxygen and hydrogen levels. In both cases leaks into liquid sodium rather than into the gas space have been considered. In the course of the work hydrogen and oxygen meters based on the galvanic cell principle have been constructed and evaluated. The former is a new device which is comparable in performance with hydrogen meters based on the ion pump. The present state of the work is briefly described in this paper.

  6. Leak detection device on flange surface

    International Nuclear Information System (INIS)

    Hanai, Koi.

    1988-01-01

    Purpose: To improve the response to fine leakage thereby enabling to leakage detection at high sensitivity, by detecting the humidity by the use of an inert dry gas. Constitution: Annular grooves are coaxially engraved to a flange and an annular water channel groove is also engraved between each of the annular grooves. Dry nitrogen flown out is blown along the circumferential direction of the water channel grooves, turned there around and then released from the end of the pipeway. If there is any water leakage, the dry nitrogen absorbs leaked water to be wettened and then reach a humidity sensor. The sensor detects the humidity in the nitrogen and delivers an output into a signal processing circuit. The processing circuit judges the absence or presence of the leakage in accordance with the detected humidity to generate an alarm signal. The time required for the blown out dry nitrogen, which turn around the water channel groove and enter the sensor, is about several minutes and the device shows excellent response even for minute leakage. (Yoshino, Y.)

  7. Use of sulfur hexafluoride and perfluorocarbon tracers in plutonium storage containers for leak detection

    International Nuclear Information System (INIS)

    Kung, J.K.

    1998-05-01

    This study involves an investigation of the feasibility of a tracer-based leak detection system for long-term interim plutonium storage. In particular, a protocol has been developed based on the use of inert tracers with varying concentrations in order to open-quotes fingerprintclose quotes or open-quotes tagclose quotes specific containers. A particular combination of tracers at specific ratios could be injected into the free volume of each container, allowing for the detection of leaks as well as determination of the location of leaking containers. Based on plutonium storage considerations, sulfur hexafluoride and four perfluorocarbon tracers were selected and should allow a wide range of viable fingerprinting combinations. A open-quotes high-lowclose quotes protocol which uses two distinct chromatographic peak areas or concentration levels, is recommended. Combinations of air exchange rates, detection durations, and detectability limits are examined in order to predict minimum tracer concentrations required for injection in storage containers

  8. Criteria for assessing the quality of signal processing techniques for acoustic leak detection

    International Nuclear Information System (INIS)

    Prabhakar, R.; Singh, O.P.

    1990-01-01

    In this paper the criteria used in the first IAEA coordinated research programme to assess the quality of signal processing techniques for sodium boiling noise detection are highlighted. Signal processing techniques, using new features sensitive to boiling and a new approach for achieving higher reliability of detection, which were developed at Indira Gandhi Centre for Atomic Research are also presented. 10 refs, 3 figs, 2 tabs

  9. 40 CFR 63.1005 - Leak repair.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Leak repair. 63.1005 Section 63.1005... Standards for Equipment Leaks-Control Level 1 § 63.1005 Leak repair. (a) Leak repair schedule. The owner or operator shall repair each leak detected no later than 15 calendar days after it is detected, except as...

  10. Development of a leak detection system using high temperature-resistant microphones

    International Nuclear Information System (INIS)

    Morishita, Yoshitsugu; Mochizuki, Hiroyasu; Watanabe, Kenshiu; Nakamura, Takahisa; Nakajima, Yoshiaki; Yamauchi, Tatsuya

    1991-01-01

    This report describes the development of a detection system of coolant leak from an inlet feeder pipe of an Advanced Thermal Reactor (ATR) with high temperature-resistant microphones. A microphone having resistance to both high temperature and high radiation dose has been developed at first. The characteristics with regard to leakage sound, attenuation of sound level in a heat insulating box for the inlet feeder pipes and background noise were clarified by laboratory experiments and measurements in the prototype ATR 'Fugen'. On the basis of these experimental findings, appropriate frequency ranges were surveyed to detect the leakage sound with a high S/N ratio under the background noise. Reliability of the system to a malfunction caused by burst-type noises observed in the plant was also investigated by statistical analyses. Finally, it was confirmed that the present method could detect a leak within a couple of seconds. (author)

  11. Development of sputter ion pump based SG leak detection system for Fast Breeder Test Reactor

    International Nuclear Information System (INIS)

    Babu, B.; Sureshkumar, K.V.; Srinivasan, G.

    2013-01-01

    Highlights: ► Development and commissioning of SG leak detection system for FBTR. ► Development of Robust method of using sputter ion pump based system. ► Modifications for improving reliability and availability. ► On line injection of hydrogen in sodium during reactor operation. ► Triplication of the SG leak detection system. - Abstract: The Fast Breeder Test Reactor (FBTR) is a 40 MWt, loop type sodium cooled fast reactor built at Indira Gandhi Centre for Atomic Research (IGCAR), Kalpakkam as a fore-runner to the second stage of Indian nuclear power programme. The reactor design is based on the French reactor Rapsodie with several modifications which include the provision of a steam-water circuit and turbo-generator. FBTR uses sodium as the coolant in the main heat transport medium to transfer heat from the reactor core to the feed water in the tertiary loop for producing superheated steam, which drives the turbo-generator. Sodium and water flow in shell and tube side respectively, separated by thin-walls of the ferritic steel tubes of the once-through steam generator (SG). Material defects in these tubes can lead to leakage of water into sodium, resulting in sodium water reactions leading to undesirable consequences. Early detection of water or steam leaks into sodium in the steam generator units of liquid metal fast breeder reactors (LMFBR) is an important requirement from safety and economic considerations. The SG leak in FBTR is detected by Sputter Ion Pump (SIP) based Steam Generator Leak Detection (SGLD) system and Thermal Conductivity Detector (TCD) based Hydrogen in Argon Detection (HAD) system. Many modifications were carried out in the SGLD system for the reactor operation to improve the reliability and availability. This paper details the development and the acquired experience of SIP based SGLD system instrumentation for real time hydrogen detection in sodium for FBTR.

  12. Pipeline leak detection method and control device therefor

    International Nuclear Information System (INIS)

    Bell, D.A.

    1983-01-01

    Leaks may be located in a pipeline by introducing into the pipeline an assembly that includes a pipe-sealing packer unit, a control unit, and a radioactive source shielded from the control unit. The control unit includes a gamma ray detector that controls the sealing and unsealing of the pipe by the packer in response to the detection of radiation exceeding a preset threshold - a detection event. The assembly is pushed through the pipeline by a relatively low fluid pressure behind it. The progress of the assembly through the pipeline may be monitored externally by a gamma ray detector

  13. Development of sodium leak detectors for PFBR

    International Nuclear Information System (INIS)

    Sylvia, J.I.; Rao, P. Vijayamohana; Babu, B.; Madhusoodanan, K.; Rajan, K.K.

    2012-01-01

    Highlights: ► Sodium leak detection system developed for PFBR using diverse principle. ► Miniature, remotely locatable diverse leak detector developed for Main Vessel. ► Mutual inductance type leak detectors designed and adapted for different locations. ► Sodium Ionisation detectors used for area monitoring. ► Crosswire type leak detector designed, developed and tested. - Abstract: The 500 MWe Prototype Fast Breeder Reactor (PFBR) is under advanced stage of construction at Kalpakkam near Chennai in India. The wide and high operating temperature, highly chemically active nature of sodium and its reaction with air make the sodium instrumentation complex over the conventional instrumentation. Over the years, traditional instruments such as wire type leak detectors, spark plug type leak detectors were developed and used in different sodium systems. The redundant and diverse leak detection method calls for development of special instrumentation for sodium systems which include sodium ionization (leak) detector for detecting minute sodium leak in addition to those systems based on mutual inductance principle. For detection of sodium leak from reactor Main Vessel (MV), diverse methods are used such as miniature, remotely locatable, Mutual Inductance type Leak Detector(MILD) and specially modified spark plug type leak detector. The design of MILD is suitably modified for detecting leak in double wall pipes and Diverse Safety Rod drive Mechanism (DSRDM). Steam/water leak in steam generator produces hydrogen and leads to high pressure and temperature in the system. Rupture disc is used as a safety device which punctures itself due to sudden pressure rise. To detect the discharge of sodium and its reaction products at the downstream of the rupture disc due to bursting of the rupture disc, cross wire type leak detector has been designed, developed and tested. The selection of the leak detection system depends on the location where leak has to be detected. This paper

  14. FLUS -innovative and robust humidity measurement for detection of smallest steam leaks

    International Nuclear Information System (INIS)

    Gloth, G.; Knoblach, W.

    2012-01-01

    This presentation will explain, how AREVA's leak detection system FLUS solves the monitoring task and how even a quantitative humidity measurements is achieved under harshest conditions with maintenance-free components in the non-accessible locations. The capabilities of the FLUS technology will be explained on 3 most recent case studies. One application covers the RPV bottom head penetrations of a BWR, a second application was installed at the RPV closure head flange of a PWR. The latest installation monitors a particular RPV bottom head penetration of a PWR. For all applications the results of in-situ leak simulation test (by means of steam injection) will be discussed in respect to sensitivity, response time and leak localization.

  15. VOLUMETRIC LEAK DETECTION IN LARGE UNDERGROUND STORAGE TANKS - VOLUME I

    Science.gov (United States)

    A set of experiments was conducted to determine whether volumetric leak detection system presently used to test underground storage tanks (USTs) up to 38,000 L (10,000 gal) in capacity could meet EPA's regulatory standards for tank tightness and automatic tank gauging systems whe...

  16. The detection, causes and repair of the small steam leaks in the PFR evaporator units

    International Nuclear Information System (INIS)

    Smedley, J.A.; Broomfield, A.M.; Anderson, R.

    1984-01-01

    The occurrence of a number of small steam leaks into the gas space above the sodium in the evaporator units of the UKAEA's Prototype Fast Reactor at Dounreay has had a significant impact on plant availability. The paper describes experience with the leak detection system and the phenomena which have caused the leaks and an outline is given of the measures which have been introduced to remedy the problem. (author)

  17. He leak detection in the presence of deuterium background in tokamak vacuum systems

    International Nuclear Information System (INIS)

    Blanchard, W.R.; Krawchuk, R.B.; Dylla, H.F.

    1982-01-01

    Helium leak detection systems for magnetic fusion devices present several unique design problems because of the large dynamic range required and the high partial pressures of D 2 encountered. We describe the design and operation of a He leak detector system for the PDX tokamak. The system consists of a differentially-pumped, low resolution, He mass spectrometer which is interfaced to the foreline of one of the torus turbomolecular pump lines. The He detector has a minimum throughput sensitivity of 10 -10 Torrxl/s, and the torus-integrated system has been designed for detection of torus leaks over the range of 10 -7 to 10 Torrxl/s. Minimum leak-rates on the 38 m 3 PDX vessel which have been quantified using this system are approx.3 x 10 -8 Torrxl/s. When PDX is operated with D 2 plasmas it is necessary to reduce the partial pressure of D 2 by a factor of 100 within the mass spectrometer to maintain this sensitivity in the presence of the torus D 2 outgassing. We have designed and incorporated a D 2 filter which employs a Zr--Al getter assembly to affect the required D 2 pressure reduction

  18. Small leak detection by measuring surface oscillation during sodium-water reaction in steam generator

    International Nuclear Information System (INIS)

    Nei, Hiromichi; Hori, Masao

    1977-01-01

    Small leak sodium-water reaction tests were conducted to develop various kinds of leak detectors for the sodium-heated steam generator in FBR. The super-heated steam was injected into sodium in a reaction vessel having a sodium free surface, simulating the steam generator. The level gauge in the reaction vessel generated the most reliable signal among detectors, as long as the leak rates were relatively high. The level gauge signal was estimated to be the sodium surface oscillation caused by hydrogen bubbles produced in sodium-water reaction. Experimental correlation was derived, predicting the amplitude as a function of leak rate, hydrogen dissolution ratio, bubble rise velocity and other parameters concerned, assuming that the surface oscillation is in proportion to the gas hold-up. The noise amplitude under normal operation without water leak was increased with sodium flow rate and found to be well correlated with Froud number. These two correlations predict that a water leak in a ''MONJU'' class (300 MWe) steam generator could possibly be detected by level gauges at a leak rate above 2 g/sec. (auth.)

  19. Role of Barium Swallow in Diagnosing Clinically Significant Anastomotic Leak following Esophagectomy

    Directory of Open Access Journals (Sweden)

    Simon Roh

    2016-04-01

    Full Text Available Background: Barium swallow is performed following esophagectomy to evaluate the anastomosis for detection of leaks and to assess the emptying of the gastric conduit. The aim of this study was to evaluate the reliability of the barium swallow study in diagnosing anastomotic leaks following esophagectomy. Methods: Patients who underwent esophagectomy from January 2000 to December 2013 at our institution were investigated. Barium swallow was routinely done between days 5–7 to detect a leak. These results were compared to clinically determined leaks (defined by neck wound infection requiring jejunal feeds and or parenteral nutrition during the postoperative period. The sensitivity and specificity of barium swallow in diagnosing clinically significant anastomotic leaks was determined. Results: A total of 395 esophagectomies were performed (mean age, 62.2 years. The indications for the esophagectomy were as follows: malignancy (n=320, high-grade dysplasia (n=14, perforation (n=27, benign stricture (n=7, achalasia (n=16, and other (n=11. A variety of techniques were used including transhiatal (n=351, McKeown (n=35, and Ivor Lewis (n=9 esophagectomies. Operative mortality was 2.8% (n=11. Three hundred and sixty-eight patients (93% underwent barium swallow study after esophagectomy. Clinically significant anastomotic leak was identified in 36 patients (9.8%. Barium swallow was able to detect only 13/36 clinically significant leaks. The sensitivity of the swallow in diagnosing a leak was 36% and specificity was 97%. The positive and negative predictive values of barium swallow study in detecting leaks were 59% and 93%, respectively. Conclusion: Barium swallow is an insensitive but specific test for detecting leaks at the cervical anastomotic site after esophagectomy.

  20. SINGLE-SHELL TANKS LEAK INTEGRITY ELEMENTS/SX FARM LEAK CAUSES AND LOCATIONS - 12127

    Energy Technology Data Exchange (ETDEWEB)

    VENETZ TJ; WASHENFELDER D; JOHNSON J; GIRARDOT C

    2012-01-25

    Washington River Protection Solutions, LLC (WRPS) developed an enhanced single-shell tank (SST) integrity project in 2009. An expert panel on SST integrity was created to provide recommendations supporting the development of the project. One primary recommendation was to expand the leak assessment reports (substitute report or LD-1) to include leak causes and locations. The recommendation has been included in the M-045-9IF Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) as one of four targets relating to SST leak integrity. The 241-SX Farm (SX Farm) tanks with leak losses were addressed on an individual tank basis as part of LD-1. Currently, 8 out of 23 SSTs that have been reported to having a liner leak are located in SX Farm. This percentage was the highest compared to other tank farms which is why SX Farm was analyzed first. The SX Farm is comprised of fifteen SSTs built 1953-1954. The tanks are arranged in rows of three tanks each, forming a cascade. Each of the SX Farm tanks has a nominal I-million-gal storage capacity. Of the fifteen tanks in SX Farm, an assessment reported leak losses for the following tanks: 241-SX-107, 241-SX-108, 241-SX-109, 241-SX-111, 241-SX-112, 241-SX-113, 241-SX-114 and 241-SX-115. The method used to identify leak location consisted of reviewing in-tank and ex-tank leak detection information. This provided the basic data identifying where and when the first leaks were detected. In-tank leak detection consisted of liquid level measurement that can be augmented with photographs which can provide an indication of the vertical leak location on the sidewall. Ex-tank leak detection for the leaking tanks consisted of soil radiation data from laterals and drywells near the tank. The in-tank and ex-tank leak detection can provide an indication of the possible leak location radially around and under the tank. Potential leak causes were determined using in-tank and ex-tank information that is not directly related to

  1. Single-Shell Tanks Leak Integrity Elements/ SX Farm Leak Causes and Locations - 12127

    Energy Technology Data Exchange (ETDEWEB)

    Girardot, Crystal [URS- Safety Management Solutions, Richland, Washington 99352 (United States); Harlow, Don [ELR Consulting Richland, Washington 99352 (United States); Venetz, Theodore; Washenfelder, Dennis [Washington River Protection Solutions, LLC Richland, Washington 99352 (United States); Johnson, Jeremy [U.S. Department of Energy, Office of River Protection Richland, Washington 99352 (United States)

    2012-07-01

    Washington River Protection Solutions, LLC (WRPS) developed an enhanced single-shell tank (SST) integrity project in 2009. An expert panel on SST integrity was created to provide recommendations supporting the development of the project. One primary recommendation was to expand the leak assessment reports (substitute report or LD-1) to include leak causes and locations. The recommendation has been included in the M-045-91F Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) as one of four targets relating to SST leak integrity. The 241-SX Farm (SX Farm) tanks with leak losses were addressed on an individual tank basis as part of LD-1. Currently, 8 out of 23 SSTs that have been reported to having a liner leak are located in SX Farm. This percentage was the highest compared to other tank farms which is why SX Farm was analyzed first. The SX Farm is comprised of fifteen SSTs built 1953-1954. The tanks are arranged in rows of three tanks each, forming a cascade. Each of the SX Farm tanks has a nominal 1-million-gal storage capacity. Of the fifteen tanks in SX Farm, an assessment reported leak losses for the following tanks: 241-SX-107, 241-SX-108, 241-SX-109, 241-SX- 111, 241-SX-112, 241-SX-113, 241-SX-114 and 241-SX-115. The method used to identify leak location consisted of reviewing in-tank and ex-tank leak detection information. This provided the basic data identifying where and when the first leaks were detected. In-tank leak detection consisted of liquid level measurement that can be augmented with photographs which can provide an indication of the vertical leak location on the sidewall. Ex-tank leak detection for the leaking tanks consisted of soil radiation data from laterals and dry-wells near the tank. The in-tank and ex-tank leak detection can provide an indication of the possible leak location radially around and under the tank. Potential leak causes were determined using in-tank and ex-tank information that is not directly related to

  2. UK status report on detection and localisation of leaks in steam generators of liquid metal fast breeder reactors

    Energy Technology Data Exchange (ETDEWEB)

    Smedley, J A [Dounreay Nuclear Power Development Establishment, Caithness, Scotland (United Kingdom)

    1978-10-01

    The development of detection and location techniques applied to defects in sodium heated steam generators in Uk has been associated primarily with the PFR commissioning program. The UK position on leak detection and location studies for LMFBR steam generators may be briefly summarised as follows: a) The Initial concept of' detection using hydrogen concentration measuring equipment in secondary circuit sodium and in steam generator gas spaces has proved sound. The system used on the PFR has been shown to work well under plant conditions in both the under sodium and gas phase modes. b) Experience with small leaks in tube to tube plate welds in the PFR steam generators has indicated the majority of leaks would be detected by the installed equipment. There is, however, a very small possibility an under sodium leak in. a ferritic tube which will quickly and easily block may not be detected before it erupts as a relatively significant defect. Methods are being sought to protect against this unlikely event, although it is recognised there is no reactor hazard but there may be a plant availability problem. c) It is concluded the single barrier concept is still valid, based on the experience in the PFR steam generator units. For future units it is intended to use ferritic boiler tube materials rather than austenitic materials. In general, however, it is concluded the material choice has been satisfactory and manufacturing methods are basically sound. Improved quality assurance methods are being sought with the aim of making future steam generators more reliable than those presently in service. d) It is recognised steam generators are still in a development regime in all countries of the world working in the LMFBR field, but the time is anticipated when a utility can order an LMFBR as a commercial proposition. An attempt has been made to quantify the information necessary to achieve this state.

  3. Vehicle-based Methane Mapping Helps Find Natural Gas Leaks and Prioritize Leak Repairs

    Science.gov (United States)

    von Fischer, J. C.; Weller, Z.; Roscioli, J. R.; Lamb, B. K.; Ferrara, T.

    2017-12-01

    Recently, mobile methane sensing platforms have been developed to detect and locate natural gas (NG) leaks in urban distribution systems and to estimate their size. Although this technology has already been used in targeted deployment for prioritization of NG pipeline infrastructure repair and replacement, one open question regarding this technology is how effective the resulting data are for prioritizing infrastructure repair and replacement. To answer this question we explore the accuracy and precision of the natural gas leak location and emission estimates provided by methane sensors placed on Google Street View (GSV) vehicles. We find that the vast majority (75%) of methane emitting sources detected by these mobile platforms are NG leaks and that the location estimates are effective at identifying the general location of leaks. We also show that the emission rate estimates from mobile detection platforms are able to effectively rank NG leaks for prioritizing leak repair. Our findings establish that mobile sensing platforms are an efficient and effective tool for improving the safety and reducing the environmental impacts of low-pressure NG distribution systems by reducing atmospheric methane emissions.

  4. Leak Detection in Water-Filled Small-Diameter Polyethylene Pipes by Means of Acoustic Emission Measurements

    OpenAIRE

    Alberto Martini; Marco Troncossi; Alessandro Rivola

    2016-01-01

    The implementation of effective strategies to manage leaks represents an essential goal for all utilities involved with drinking water supply in order to reduce water losses affecting urban distribution networks. This study concerns the early detection of leaks occurring in small-diameter customers’ connections to water supply networks. An experimental campaign was carried out in a test bed to investigate the sensitivity of Acoustic Emission (AE) monitoring to water leaks. Damages were artifi...

  5. Passive Leak Detection Using Commercial Hydrogen Colorimetric Indicator

    Energy Technology Data Exchange (ETDEWEB)

    Hartmann, Kevin [National Renewable Energy Lab. (NREL), Golden, CO (United States); Buttner, William [National Renewable Energy Lab. (NREL), Golden, CO (United States); Burgess, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States); Rivkin, Carl [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-09-01

    Element One, Inc. (www.elem.com), a small business with in Boulder, CO, has been developing hydrogen detection technology based upon a highly selective colorimetric indicator. In its native state, the indicator pigment is a pale gray color, but becomes black upon exposure to hydrogen. The colorimetric change can be readily observed by the naked eye without the need for supplemental electronics or other hardware. Recently, the colorimetric indicator was integrated into a pliable, self-adhesive tape that can readily wrap around pneumatic fittings to serve as a hydrogen leak detector. A prototype version of the Element One indicator tape was tested within an NREL hydrogen system and successfully identified the unexpected presence of a small leak; a summary document for this case study is presented in Appendix 1. The tape was subsequently configured into 10-foot rolls as a product prototype that has just recently been commercialized and marketed under the tradename DetecTape(R). Figure 1 shows the commercial version of DetecTape along with an indicator sample in its native state and one that had been exposed to hydrogen. DetecTape is a self-adhesive silicone-based tape impregnated with a proprietary hydrogen-sensitive indicator based on transition metal oxides. A length of the tape can be cut from the roll and stretched by a factor of two or three times around a fitting. Due to the self-adhesive property of the tape, this provides a tight seal around the fitting. The seal is not hermetic, and is not intended to prevent the release of a leaking gas. However, a portion of the hydrogen leaking from a wrapped fitting will pass through the tape and react with the active indicator impregnated within the tape, thereby inducing blackening.

  6. Development of a low cost unmanned aircraft system for atmospheric carbon dioxide leak detection

    Science.gov (United States)

    Mitchell, Taylor Austin

    Carbon sequestration, the storage of carbon dioxide gas underground, has the potential to reduce global warming by removing a greenhouse gas from the atmosphere. These storage sites, however, must first be monitored to detect if carbon dioxide is leaking back out to the atmosphere. As an alternative to traditional large ground-based sensor networks to monitor CO2 levels for leaks, unmanned aircraft offer the potential to perform in-situ atmospheric leak detection over large areas for a fraction of the cost. This project developed a proof-of-concept sensor system to map relative carbon dioxide levels to detect potential leaks. The sensor system included a Sensair K-30 FR CO2 sensor, GPS, and altimeter connected an Arduino microcontroller which logged data to an onboard SD card. Ground tests were performed to verify and calibrate the system including wind tunnel tests to determine the optimal configuration of the system for the quickest response time (4-8 seconds based upon flowrate). Tests were then conducted over a controlled release of CO 2 in addition to over controlled rangeland fires which released carbon dioxide over a large area as would be expected from a carbon sequestration source. 3D maps of carbon dioxide were developed from the system telemetry that clearly illustrated increased CO2 levels from the fires. These tests demonstrated the system's ability to detect increased carbon dioxide concentrations in the atmosphere.

  7. Detection of leaks in steam lines by distributed fibre-optic temperature sensing (DTS)

    Energy Technology Data Exchange (ETDEWEB)

    Craik, N G [Maritime Nuclear, Fredericton, N.B. (Canada)

    1997-12-31

    This paper describes an instrumentation system concept which should be capable of early detection of a leak-before-break in main steam lines. Distributed fibre-optic Temperature Sensing (DTS) systems have been used in commercial application for a few years now, but in other industries and applications. DTS uses very long fibre optical cable both as a temperature sensor and as a means of bringing the information back from the sensor to the terminal equipment. The entire length of the fibre is sensitive to temperature and each resolvable section of fibre is equivalent to a point sensor. This commercially available DTS system could be adapted to indicate leaks in steam lines. The fibre-optic cable could either be run either just underneath the aluminium sheathing covering the installation over a steam line, or between the two layers of insulation. This would detect an increase in the temperature of the insulation due to a steam leak. 1 ref., 4 figs.

  8. Detection of leaks in steam lines by distributed fibre-optic temperature sensing (DTS)

    International Nuclear Information System (INIS)

    Craik, N.G.

    1996-01-01

    This paper describes an instrumentation system concept which should be capable of early detection of a leak-before-break in main steam lines. Distributed fibre-optic Temperature Sensing (DTS) systems have been used in commercial application for a few years now, but in other industries and applications. DTS uses very long fibre optical cable both as a temperature sensor and as a means of bringing the information back from the sensor to the terminal equipment. The entire length of the fibre is sensitive to temperature and each resolvable section of fibre is equivalent to a point sensor. This commercially available DTS system could be adapted to indicate leaks in steam lines. The fibre-optic cable could either be run either just underneath the aluminium sheathing covering the installation over a steam line, or between the two layers of insulation. This would detect an increase in the temperature of the insulation due to a steam leak. 1 ref., 4 figs

  9. Using Decision Trees to Detect and Isolate Simulated Leaks in the J-2X Rocket Engine

    Science.gov (United States)

    Schwabacher, Mark A.; Aguilar, Robert; Figueroa, Fernando F.

    2009-01-01

    The goal of this work was to use data-driven methods to automatically detect and isolate faults in the J-2X rocket engine. It was decided to use decision trees, since they tend to be easier to interpret than other data-driven methods. The decision tree algorithm automatically "learns" a decision tree by performing a search through the space of possible decision trees to find one that fits the training data. The particular decision tree algorithm used is known as C4.5. Simulated J-2X data from a high-fidelity simulator developed at Pratt & Whitney Rocketdyne and known as the Detailed Real-Time Model (DRTM) was used to "train" and test the decision tree. Fifty-six DRTM simulations were performed for this purpose, with different leak sizes, different leak locations, and different times of leak onset. To make the simulations as realistic as possible, they included simulated sensor noise, and included a gradual degradation in both fuel and oxidizer turbine efficiency. A decision tree was trained using 11 of these simulations, and tested using the remaining 45 simulations. In the training phase, the C4.5 algorithm was provided with labeled examples of data from nominal operation and data including leaks in each leak location. From the data, it "learned" a decision tree that can classify unseen data as having no leak or having a leak in one of the five leak locations. In the test phase, the decision tree produced very low false alarm rates and low missed detection rates on the unseen data. It had very good fault isolation rates for three of the five simulated leak locations, but it tended to confuse the remaining two locations, perhaps because a large leak at one of these two locations can look very similar to a small leak at the other location.

  10. Permanent underwater leak detector

    International Nuclear Information System (INIS)

    Costello, L; McStay, D; Moodie, D; Kane, D

    2009-01-01

    A new optoelectronic sensor for the real time monitoring of key components such as valves and connectors within the subsea production equipment for leaks of hydraulic fluid is reported. The sensor is capable of detecting low concentrations of such fluids, allowing the early detection of small leaks, and the ability to monitor the evolution of the leak-rate with time, hence providing an important new tool in complying with environmental requirements, enabling early intervention and optimising subsea production

  11. Study of leak detection using tracers in a bottling plant in Mexico

    International Nuclear Information System (INIS)

    Vizuet Gonzalez, Jorge; Reyes Jimenez, Jose Luis; Molina, Gustavo

    2005-01-01

    The Instituto Nacional de Investigaciones Nucleares (ININ), Mexico, promoted the application of different techniques, involving the use of radioactive materials. Among them is the use of radioactive material as a medium tracer in the industry. Below is a study of locating leaks in ducts collectors of process water of a bottling plant which had several problems, one was not able to stop production, and most important, having to disassemble a large amount of machinery and equipment, in order to open the floor and locate the leak

  12. Stimulated leaks found with SmartBall tool

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2011-05-15

    Pure Technologies has developed a SmartBall leak detection tool which can be used in oil and gas pipelines. This tool contains acoustic sensors which listen for leaks and other problems in pipelines. Pig tracking units are used to track the tool along with receivers positioned on the pipe. With these technologies, SmartBall is able to detect small leaks that conventional methods would not detect and to assess their location accurately. Two runs on a Petrobras pipeline in Brazil highlighted the effectiveness of this technology, detecting three simulated leaks as small as 240mL/min. In addition, this system can give an estimation of the leak rate and traverse non piggable pipelines. Software is then used to analyze data and generate a report giving the size and location of the leaks identified. SmartBall is a technology capable of detecting small leaks and locating them in all sorts of oil and gas pipelines.

  13. Hermetic compartments leak-tightness enhancement

    International Nuclear Information System (INIS)

    Murani, J.

    2000-01-01

    In connection with the enhancement of the nuclear safety of the Jaslovske Bohunice V-1 NPP actions for the increase of the leak tightness are performed. The reconstruction has been done in the following directions: hermetic compartments leak tightness enhancement; air lock installation; installation of air lock in SP 4 vent system; integrated leakage rate test to hermetic compartments with leak detection. After 'major' leaks on the hermetic boundary components had been eliminated, since 1994 works on a higher qualitative level began. The essence of the works consists in the detection and identification of leaks in the structural component of the hermetic boundary during the planned refueling outages. The results of the Small Reconstruction and gradual enhancement of leak tightness are presented

  14. Doppler method leak detection for LMFBR steam generators. Pt. 2. Detection characteristics of bubble in-water using large scale SG model

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi

    2000-01-01

    To prevent the expansion of tube damage and to maintain structural integrity in the steam generators (SGs) of a fast breeder reactor (FBR), it is necessary to detect precisely and immediately the leakage of water from heat transfer tubes. Therefore, an active acoustic method was developed. Previous studies have revealed that, in practical steam generators, the active acoustic method can detect bubbles of 10 l/s within 10 seconds. However to prevent the expansion of damage to neighboring tubes, it is necessary to detect smaller leakages of water from the heat transfer tubes. The Doppler method is designed to detect small leakages and to find the source of a leak before damage spreads to neighboring tubes. The detection sensitivity of the Doppler method and the influence of background noise were investigated experimentally. In-water experiments were performed using an SG full-sector model that simulates actual SGs. The results show that the Doppler method can detect bubbles of 0.1 l/s (equivalent to a water leak rate of about 0.1 g/s) within a few seconds and that the background noise has little effect on water leak detection performance. The Doppler method thus has great potential for the detection of water leakage in SGs. (author)

  15. NDE of stainless steel and on-line leak monitoring of LWRs. Annual report, October 1983-September 1984

    International Nuclear Information System (INIS)

    Kupperman, D.S.; Claytor, T.N.; Prine, D.W.

    1985-04-01

    The application of ultrasonic velocity and attenuation measurements to characterize the microstructure of structural materials is discussed. Results of a workshop on NDE of stainless steel pipes with weld overlays are presented. No currently available, single leak-detection method for reactor cooling systems combines optimal leakage detection sensitivity, leak-locating ability, and leakage measurement accuracy. Current practice with regard to leak detection has been reviewed and assessed for 74 operating plants, including both BWRs and PWRs. Seven cracks, including three field-induced IGSCC specimens and two thermal-fatigue cracks, have been installed in the acoustic leak detection (ALD) facility at ANL. Cross-correlation techniques to improve leak location capabilities have been successfully demonstrated on the laboratory pipe run by use of 375-kHz transducers on waveguides and an electronically simulated leak signal. Preliminary leak detection and location tests have also been run at ANL with a breadboard ALD system. In addition to ALD experiments, laboratory tests have been carried out to help assess the effectiveness of moisture-sensitive tape

  16. Technical basis for inner container leak detection sensitivity goals in 3013 DE surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Berg, John M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-11

    Helium leak checking of 3013 inner container lids is under consideration for addition to DE Surveillance tasks as an improved means to detect any through-wall flaws that may have formed during storage. This white paper evaluates whether leak checking at DE could replace and improve upon the current method of comparing gas compositions and pressures within the inner and outer containers. We have used viscous and molecular flow equations in ANSI N14.5 to calculate what the measured standard helium leak rate would be for hypothetical leaks of three different sizes. For comparison, we have also calculated the effects on gas composition and pressure differences as a function of pre-DE storage time for the same three leak sizes, using molecular and viscous flow equations as well as diffusion equations to predict the relevant gas transport. For a hypothetical leak that would be measured at 1x10-7 std cc/sec, likely an achievable sensitivity using helium leak checking at DE, the calculations predict no measurable effect on pressure difference or gas composition as measured by DE gas analysis. We also calculate that it would take over 200 years for water vapor to diffuse through a 10-7 std cc/sec leak enough to raise the RH outer container to half the RH value in the inner container. A leak 100 times larger, which would be measured at 1x10-5 std cc/sec, the same water vapor diffusion would take at least 14 years. Our conclusion is that helium leak checking will be useful even at a sensitivity of 1x10-5 std cc/sec, and a significant improvement over current DE methods at a sensitivity of 1x10-7 std cc/sec.

  17. A study on a real-time leak detection method for pressurized liquid refrigerant pipeline based on pressure and flow rate

    International Nuclear Information System (INIS)

    Tian, Shen; Du, Juanli; Shao, Shuangquan; Xu, Hongbo; Tian, Changqing

    2016-01-01

    Highlights: • A real-time leak detection method is developed for ammonia pipeline in cold storage. • A locating algorithm based on pressure difference profile is provided. • This method is validated by R22 and ammonia leak experiments. • The minimum detectable leak ratio is 1% for R22 and 4% for ammonia. • The location estimating errors are −27% ~ 17% for R22 and −27% ~ 27% for ammonia. - Graphical Abstract: - Abstract: Leakage from pressurized liquid ammonia pipeline has been a serious problem in large commercial cold storages because it might release large amount of liquid ammonia and without safety supervision in daily operations. The present paper shows a detection method for a pressurized liquid ammonia pipeline with a leak. The variations of pressure, flow rate and pressure difference profile are studied. A leak indicator (σ), proposed with the one-dimensional steady-state flow model, is used to detect the leak occurrence by comparing it with a threshold value (σ Le ). A locating algorithm based on pressure difference profile along the pipeline is also proposed, which has considered the effect of the static pressure increase at the leak point. Experiments on different leak positions and ratios from liquid R22 and ammonia pipelines are carried out to validate this method. It is found that, with a relatively low false alarm rate (as three percent), the minimum detectable leak ratio reached 1% for the R22 pipeline and 4% for the ammonia pipeline. The locating errors are between −27% ~ 17% for R22 pipeline and −27% ~ 27% for ammonia pipeline.

  18. Mobile Measurement of Methane and Ethane for the Detection and Attribution of Natural Gas Pipeline Leaks Using Off-Axis Integrated Output Spectroscopy

    Science.gov (United States)

    Leen, J. B.; Spillane, S.; Gardner, A.; Hansen, P. C.; Gupta, M.; Baer, D. S.

    2015-12-01

    Natural gas leaks pose a risk to public safety both because of potential explosions as well as from the greenhouse gas potential of fugitive methane. The rapid and cost effective detection of leaks in natural gas distribution is critical to providing a system that is safe for the public and the environment. Detection of methane from a mobile platform (vehicles, aircraft, etc.) is an accepted method of identifying leaks. A robust approach to differentiating pipeline gas (thermogenic) from other biogenic sources is the detection of ethane along with methane. Ethane is present in nearly all thermogenic gas but not in biogenic sources and its presence can be used to positively identify a gas sample. We present a mobile system for the simultaneous measurement of methane and ethane that is capable of detecting pipeline leaks and differentiating pipeline gas from other biogenic sources such as landfills, swamps, sewers, and enteric fermentation. The mobile system consists of a high precision GPS, sonic anemometer, and methane/ethane analyzer based on off-axis integrated cavity output spectroscopy (OA-ICOS). In order to minimize the system cost and facilitate the wide use of mobile leak detection, the analyzer operates in the near-infrared portion of the spectrum where lasers and optics are significantly less costly than in the mid-infrared. The analyzer is capable of detecting methane with a precision of detecting ethane with a precision of detection of leaks at speeds up to 50 mph. The sonic anemometer, GPS and analyzer inlet are mounted to a generic roof rack for attachment to available fleet vehicles. The system can detect leaks having a downwind concentration of as little as 10 ppb of methane above ambient, while leaks 500 ppb above ambient can be identified as thermogenic with greater than 99% certainty (for gas with 6% ethane). Finally, analysis of wind data provides an estimate of leak direction and distance. The system presented provides a robust, cost effective

  19. 40 CFR 63.424 - Standards: Equipment leaks.

    Science.gov (United States)

    2010-07-01

    ....424 Standards: Equipment leaks. (a) Each owner or operator of a bulk gasoline terminal or pipeline... location of all equipment in gasoline service at the facility. (c) Each detection of a liquid or vapor leak... replacement of leaking equipment shall be completed within 15 calendar days after detection of each leak...

  20. Humos monitoring system of leaks in to the containment atmosphere

    International Nuclear Information System (INIS)

    Matal, O.; Zaloudek, J.; Matal, O. Jr.; Klinga, J.; Brom, J.

    1997-01-01

    HUmidity MOnitoring System (HUMOS) has been developed and designed to detect the presence of leak in selected primary circuit high energy pipelines and components that are evaluated from the point of view of Leak Before Break (LBB) requirements. It also requires to apply technical tools for detection and identification of coolant leaks from primary circuit and components of PWRs reactors. Safety significant of leaks depend on: leak source (location); leak rate, and leak duration. Therefore to detect and monitor coolant leaks in to the containment atmosphere during reactor operation is one of important safety measures. As potential leak sources flange connection in the upper head region of WWER reactors can be considered. HUMOS does not rely on the release of radioactivity to detect leaks but rather the relies on detection of moisture in the air resulting from a primary boundary leak. Because HUMOS relies on moisture and temperature detection, leaks can be detected without requiring the reactor to be critical. Therefore leaks can be detected during integrity pressure tests and any other mode of operation provided the reactor ventilation system is operating and primary circuit and components are pressurized. 3 figs

  1. Leak detection system for RBMK coolant circuit

    International Nuclear Information System (INIS)

    Cherkashov, Ju.M.; Strelkov, B.P.; Korolev, Yu.V.; Eperin, A.P.; Kozlov, E.P.; Belyanin, L.A.; Vanukov, V.N.

    1996-01-01

    In report the description of an object of the control is submitted, requests to control of leak-tightness and functioning of system are formulated, analysis of a current status on NPP with RBMK is submitted, review of methods of the leak-tightness monitoring, their advantage and defects with reference to conditions and features of a design RBMK is indicated, some results of tests and operation of various monitoring methods are submitted, requests on interaction of operative staff, leak-tightness monitoring system and protection system of reactor are submitted. (author). 11 figs, 1 tab

  2. Leak detection system for RBMK coolant circuit

    Energy Technology Data Exchange (ETDEWEB)

    Cherkashov, Ju M; Strelkov, B P; Korolev, Yu V; Eperin, A P; Kozlov, E P; Belyanin, L A; Vanukov, V N [Leningrad Nuclear Power Plant, Leningrad (Russian Federation). Research and Development Inst. of Power Engineering

    1997-12-31

    In report the description of an object of the control is submitted, requests to control of leak-tightness and functioning of system are formulated, analysis of a current status on NPP with RBMK is submitted, review of methods of the leak-tightness monitoring, their advantage and defects with reference to conditions and features of a design RBMK is indicated, some results of tests and operation of various monitoring methods are submitted, requests on interaction of operative staff, leak-tightness monitoring system and protection system of reactor are submitted. (author). 11 figs, 1 tab.

  3. New method of leak detecting in diagnostic of gas pipeline system

    International Nuclear Information System (INIS)

    Kalinowski, K.; Dabrowski, A.; Sobkiewicz, D.; Oracz, H.

    2007-01-01

    This report describes new directions in gas transmission pipelines diagnostics as well as new methods and equipment used to detect leaks. It was also shown that efficient and functional diagnostics system is the necessary condition to keep the exploitation of transmission systems safe. (author)

  4. Leak detection, monitoring, and mitigation technology trade study update

    International Nuclear Information System (INIS)

    HERTZEL, J.S.

    1998-01-01

    This document is a revision and update to the initial report that describes various leak detection, monitoring, and mitigation (LDMM) technologies that can be used to support the retrieval of waste from the single-shell tanks (SST) at the Hanford Site. This revision focuses on the improvements in the technical performance of previously identified and useful technologies, and it introduces new technologies that might prove to be useful

  5. Leak detection, monitoring, and mitigation technology trade study update

    Energy Technology Data Exchange (ETDEWEB)

    HERTZEL, J.S.

    1998-11-10

    This document is a revision and update to the initial report that describes various leak detection, monitoring, and mitigation (LDMM) technologies that can be used to support the retrieval of waste from the single-shell tanks (SST) at the Hanford Site. This revision focuses on the improvements in the technical performance of previously identified and useful technologies, and it introduces new technologies that might prove to be useful.

  6. Research and development of a high-temperature helium-leak detection system (joint research). Part 1 survey on leakage events and current leak detection technology

    Energy Technology Data Exchange (ETDEWEB)

    Sakaba, Nariaki; Nakazawa, Toshio; Kawasaki, Kozo [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment; Urakami, Masao; Saisyu, Sadanori [Japan Atomic Power Co., Tokyo (Japan)

    2003-03-01

    In High Temperature Gas-cooled Reactors (HTGR), the detection of leakage of helium at an early stage is very important for the safety and stability of operations. Since helium is a colourless gas, it is generally difficult to identify the location and the amount of leakage when very little leakage has occurred. The purpose of this R and D is to develop a helium leak detection system for the high temperature environment appropriate to the HTGR. As the first step in the development, this paper describes the result of surveying leakage events at nuclear facilities inside and outside Japan and current gas leakage detection technology to adapt optical-fibre detection technology to HTGRs. (author)

  7. Leak testing and repair of fusion devices

    International Nuclear Information System (INIS)

    Kozman, T.A.

    1983-01-01

    The leak testing, reporting and vacuum leak repair techniques of the MFTF yin-yang number one magnet system, the world's largest superconducting magnet system, are discussed. Based on this experience, techniques will be developed for testing and repairing leaks on the 42 MFTF-B magnets. The leak-hunting techniques for the yin-yang magnet systems were applied to two helium circuits (the coil bundle and guard vacuum; both require helium flow for magnet cooldown), their associated piping, liquid nitrogen radiation shields, and piping. Additionally, during MFTF-B operation there will be warm water plasma shields and piping that require leak checking

  8. The leakage problem in vacuum system. Realization of a mass spectrometer detecting leaks; Le probleme des fuites en technique du vide. Realisation d'un spectrometre de masse detecteur de fuite

    Energy Technology Data Exchange (ETDEWEB)

    Geller, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1954-11-15

    In the first part of this paper we consider the problem of leaks in vacuum systems, and their detection. We consider in particular the method of detection by means of a helium spectrometer. The second part deals with the experimental set p. The analyser and the ion source have been studied in great detail, and we have also discussed the technological and mechanical aspects of the apparatus and its performances. (author) [French] Dans la premiere partie de ce travail, nous traitons le probleme des fuites en technique du vide et leur detection en general. La methode de detection par spectrometre a helium y est envisagee plus particulierement. La deuxieme partie de l'article est consacree a la realisation du spectrometre. Le tube analyseur et la source d'ions y sont etudies en detail. Nous exposons de meme les conceptions technologiques et mecaniques de l'appareil ainsi que ses performances. (auteur)

  9. Contrast-enhanced swallow study sensitivity for anastomotic leak detection in post-esophagectomy patients.

    Science.gov (United States)

    Mejía-Rivera, S; Pérez-Marroquín, S A; Cortés-González, R; Medina-Franco, H

    2018-03-07

    Esophagectomy is a highly invasive surgery and one of its postoperative complications is anastomotic leakage, occurring in 53% of cases. The aim of the present study was to determine the sensitivity of the contrast-enhanced swallow study as a method for diagnosing anastomotic leak in patients that underwent esophagectomy. The present retrospective study included the case records of patients that underwent esophagectomy with reconstruction and cervical anastomosis at the Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán within the time frame of January 1, 2000 and May 31, 2006. Demographic, clinical, and laboratory data emphasizing clinical and radiographic anastomotic leak detection were identified. Descriptive statistics were carried out and contrast-enhanced swallow study sensitivity for diagnosing leakage was calculated. Seventy patients were included in the analysis. The mean age of the patients was 50.6 years, 51 of the patients were men (72.86%), and 19 were women (27.14%). Indications for surgery were benign lesion in 29 patients (41.4%) and malignant lesion in 41 (58.6%). A total of 44.3% of the patients presented with a comorbidity, with diabetes mellitus and high blood pressure standing out. Thirty patients (42.85%) presented with anastomotic leak. Contrast-enhanced swallow study sensitivity for leak detection was 43.33%. The diagnostic sensitivity of the contrast-enhanced swallow study was very low. Therefore, we recommend the discontinuation of its routine use as a method for diagnosing anastomotic leaks. Copyright © 2018 Asociación Mexicana de Gastroenterología. Publicado por Masson Doyma México S.A. All rights reserved.

  10. Role of Outgassing of ITER Vacuum Vessel In-Wall Shielding Materials in Leak Detection of ITER Vacuum Vessel

    Science.gov (United States)

    Maheshwari, A.; Pathak, H. A.; Mehta, B. K.; Phull, G. S.; Laad, R.; Shaikh, M. S.; George, S.; Joshi, K.; Khan, Z.

    2017-04-01

    ITER Vacuum Vessel is a torus-shaped, double wall structure. The space between the double walls of the VV is filled with In-Wall Shielding Blocks (IWS) and Water. The main purpose of IWS is to provide neutron shielding during ITER plasma operation and to reduce ripple of Toroidal Magnetic Field (TF). Although In-Wall Shield Blocks (IWS) will be submerged in water in between the walls of the ITER Vacuum Vessel (VV), Outgassing Rate (OGR) of IWS materials plays a significant role in leak detection of Vacuum Vessel of ITER. Thermal Outgassing Rate of a material critically depends on the Surface Roughness of material. During leak detection process using RGA equipped Leak detector and tracer gas Helium, there will be a spill over of mass 3 and mass 2 to mass 4 which creates a background reading. Helium background will have contribution of Hydrogen too. So it is necessary to ensure the low OGR of Hydrogen. To achieve an effective leak test it is required to obtain a background below 1 × 10-8 mbar 1 s-1 and hence the maximum Outgassing rate of IWS Materials should comply with the maximum Outgassing rate required for hydrogen i.e. 1 x 10-10 mbar 1 s-1 cm-2 at room temperature. As IWS Materials are special materials developed for ITER project, it is necessary to ensure the compliance of Outgassing rate with the requirement. There is a possibility of diffusing the gasses in material at the time of production. So, to validate the production process of materials as well as manufacturing of final product from this material, three coupons of each IWS material have been manufactured with the same technique which is being used in manufacturing of IWS blocks. Manufacturing records of these coupons have been approved by ITER-IO (International Organization). Outgassing rates of these coupons have been measured at room temperature and found in acceptable limit to obtain the required Helium Background. On the basis of these measurements, test reports have been generated and got

  11. 40 CFR 63.1024 - Leak repair.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Leak repair. 63.1024 Section 63.1024... Standards for Equipment Leaks-Control Level 2 Standards § 63.1024 Leak repair. (a) Leak repair schedule. The owner or operator shall repair each leak detected as soon as practical, but not later than 15 calendar...

  12. A Small Leak Detection Method Based on VMD Adaptive De-Noising and Ambiguity Correlation Classification Intended for Natural Gas Pipelines.

    Science.gov (United States)

    Xiao, Qiyang; Li, Jian; Bai, Zhiliang; Sun, Jiedi; Zhou, Nan; Zeng, Zhoumo

    2016-12-13

    In this study, a small leak detection method based on variational mode decomposition (VMD) and ambiguity correlation classification (ACC) is proposed. The signals acquired from sensors were decomposed using the VMD, and numerous components were obtained. According to the probability density function (PDF), an adaptive de-noising algorithm based on VMD is proposed for noise component processing and de-noised components reconstruction. Furthermore, the ambiguity function image was employed for analysis of the reconstructed signals. Based on the correlation coefficient, ACC is proposed to detect the small leak of pipeline. The analysis of pipeline leakage signals, using 1 mm and 2 mm leaks, has shown that proposed detection method can detect a small leak accurately and effectively. Moreover, the experimental results have shown that the proposed method achieved better performances than support vector machine (SVM) and back propagation neural network (BP) methods.

  13. Evaluation of a leaking crack in an irradiated CANDU pressure tube

    International Nuclear Information System (INIS)

    Coleman, C.E.; Simpson, L.A.

    1988-06-01

    Leak-before-break is used in CANDU reactors as part of the defence against rupture of the pressure tubes. Two important features of this technique are the action time available for detection of a leaking crack and the size of the leak allowing crack location. Support for continued reliance on leak-before-break is being obtained from experiments, on irradiated Zr-2.5 Nb pressure tubes attached to their end fittings, that simulate the behaviour of a leaking crack in a reactor. At reactor operating temperatures leaking cracks grow more slowly than dry cracks in the laboratory because they are cooled when pressurised water flashes to steam on their surface. These cracks remain stable till they are at least 70 mm long. From the results of these experiments the action time is at least 100 h. The leak rate increases rapidly when a through-wall crack extends a small amount, thus greatly assisting with crack location

  14. 40 CFR 65.105 - Leak repair.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Leak repair. 65.105 Section 65.105... FEDERAL AIR RULE Equipment Leaks § 65.105 Leak repair. (a) Leak repair schedule. The owner or operator shall repair each leak detected as soon as practical but not later than 15 calendar days after it is...

  15. Functionalized multi-walled carbon nanotube based sensors for distributed methane leak detection

    Science.gov (United States)

    This paper presents a highly sensitive, energy efficient and low-cost distributed methane (CH4) sensor system (DMSS) for continuous monitoring, detection and localization of CH4 leaks in natural gas infrastructure such as transmission and distribution pipelines, wells, and produc...

  16. Production of 82Br Radiotracer and its Application on Leak Detection in Buried Pipelines

    International Nuclear Information System (INIS)

    Dawed, E. M.; Alwerfalli, M. A.; Ben ayad, S. M.

    2008-01-01

    This paper represents a proper technique called a pig method technique. This technique was applied for leakage detection on the 10 inch diameter and 54 km long underground pipeline carrying the crude oil derivatives from Albrega pumping station (Alzawia) to the Tareeq Almatar distribution center (Tripoli). For this technique, a suitable radioisotope ( 82 BR) was produced through irradiation of potassium bromide target under flux of 1014 n/cm 2 .sec. After 24 hours cooling of the target, 74 GBq (2 Ci) activity was achieved. The chemical reaction to get the radioactive source in a gaseous form was carried on in a special generator. A generated Methyl bromide gas was injected into the pipeline fluid stream (Light Naphtha), and then DN-1 water proof detector was lunched in the same pipeline, afterwards analysis of the obtained data from the detector passage in the pipeline indicated that no changes in the background activity a long the pipeline except the markers positions. This result proved that the pipeline was free of leaks (author)

  17. The SNR-300 steam generator small leak detection system

    International Nuclear Information System (INIS)

    Dumm, K.

    1984-01-01

    Small leak detection in the SNR-300 steam generator moduls is achieved by hydrogen meters. Development and design of the Nickel membrane - ion getter pump combination are described and sensitivity requests derived. Results of calibration tests by water/steam injections in a sodium loop are presented. The arrangement and interconnection of signals in SNR-300 are given and possibilities for inservice calibrations are discussed, supported by long time operation tests in the KNK-reactor plant. (author)

  18. Localization of leaks in underground pipes with the application of radioactive isotopes

    International Nuclear Information System (INIS)

    Klupa, A.; Morawiec, J.

    1983-01-01

    A method of leaks localization on gas pipe-lines during resistance and tightness tests was elaborated. The leaks were localized using tracer technique. Sodium 24 was used as a tracer for short sections of the pipe-line (up to 30 km). Only 1 m 3 of water with a tracer was introduced into the pipe-line. A measuring probe was also put into pipe-line. All leaks were detected and the method appeared useful. For the longer sections of the pipe-line iodine 131 ought to be used. (A.S.)

  19. A Small Leak Detection Method Based on VMD Adaptive De-Noising and Ambiguity Correlation Classification Intended for Natural Gas Pipelines

    Directory of Open Access Journals (Sweden)

    Qiyang Xiao

    2016-12-01

    Full Text Available In this study, a small leak detection method based on variational mode decomposition (VMD and ambiguity correlation classification (ACC is proposed. The signals acquired from sensors were decomposed using the VMD, and numerous components were obtained. According to the probability density function (PDF, an adaptive de-noising algorithm based on VMD is proposed for noise component processing and de-noised components reconstruction. Furthermore, the ambiguity function image was employed for analysis of the reconstructed signals. Based on the correlation coefficient, ACC is proposed to detect the small leak of pipeline. The analysis of pipeline leakage signals, using 1 mm and 2 mm leaks, has shown that proposed detection method can detect a small leak accurately and effectively. Moreover, the experimental results have shown that the proposed method achieved better performances than support vector machine (SVM and back propagation neural network (BP methods.

  20. Using Decision Trees to Detect and Isolate Leaks in the J-2X

    Data.gov (United States)

    National Aeronautics and Space Administration — Full title: Using Decision Trees to Detect and Isolate Simulated Leaks in the J-2X Rocket Engine Mark Schwabacher, NASA Ames Research Center Robert Aguilar, Pratt...

  1. Developing works to detect fatigue cracks (small sodium leak detector and acoustic emission

    International Nuclear Information System (INIS)

    Kikuchi, M.; Sakakibara, Y.; Nagata, T.

    1980-01-01

    Continuous monitoring of fatigue cracks was performed (using both sodium leak detector and AE measuring system) through the creep-fatigue test of 304 stainless steel long elbow as part of the test series to establish the structural reliability of the Prototype FBR primary heat transport piping system. The sodium leak detector was a system composed mainly of SID (Sodium Ionization Detector) and DPD (Deferential Pressure Detector), that was developed by HITACHI Ltd. under a contract with PNC. The AE system was Synthetic AE Measuring and Analyzing system that was developed at FBR Safety Section to measure and analyze AE at various piping component tests. The test was continued until a sodium leakage was detected by the contact-type sodium leak detector attached to the test assembly, after about 4 weeks operation under cyclic loading at 600 deg. C. The following conclusions were obtained: (1) The sodium leak detector, both SID and DPD, indicated sodium leakage clearly, some hours before the contact-type detector did, even under an environment of air that contains ordinary humidity (Leaked sodium was estimated to be less than 15 grams after completion of the test); (2) The AE method indicated location and seriousness of the fatigue cracks, apparently before the crack penetration occurred. (author)

  2. Performance evaluation of PFBR wire type sodium leak detectors

    International Nuclear Information System (INIS)

    Vijayakumar, G.; Rajan, K.K.; Nashine, B.K.; Chandramouli, S.; Madhusoodanan, K.; Kalyanasundaram, P.

    2011-01-01

    Highlights: → Performance evaluation of wire type leak detectors was conducted in LEENA facility by creating sodium leaks. → The lowest leak rate of 214 g/h was detected in 50 min and the highest detection time was 6 h for a leak rate of 222 g/h. → Factors affecting the leak detection time are packing density of thermal insulation, layout of heater, temperature, etc. → Relationship between leak rate and detection time was established and a leak rate of 100 g/h is likely to be detected in 11.1 h. → Contact resistance of leaked sodium increased to 3.5 kilo ohms in 20 h. - Abstract: Wire type leak detectors working on conductivity principle are used for detecting sodium leak in the secondary sodium circuits of fast breeder reactors. It is required to assess the performance of these detectors and confirm that they are meeting the requirements. A test facility by name LEENA was constructed at Indira Gandhi Centre for Atomic Research (IGCAR), Kalpakkam to test the wire type leak detector lay out by simulating different sodium leak rates. This test facility consists of a sodium dump tank, a test vessel, interconnecting pipelines with valves, micro filter and test section with leak simulators. There are three different test sections in the test set up of length 1000 mm each. These test sections simulate piping of Prototype Fast Breeder Reactor (PFBR) secondary circuit and the wire type leak detector layout in full scale. All test sections are provided with leak simulators. A leak simulator consists of a hole of size one mm drilled in the test section and closed with a tapered pin. The tapered pin position in the hole is adjusted by a screw mechanism and there by the annular gap of flow area is varied for getting different leak rates. Various experiments were conducted to evaluate the performance of the leak detectors by creating different sodium leak rates. This paper deals with the details of wire type leak detector layout for the secondary sodium circuit of

  3. Leak Detection in Water-Filled Small-Diameter Polyethylene Pipes by Means of Acoustic Emission Measurements

    Directory of Open Access Journals (Sweden)

    Alberto Martini

    2016-12-01

    Full Text Available The implementation of effective strategies to manage leaks represents an essential goal for all utilities involved with drinking water supply in order to reduce water losses affecting urban distribution networks. This study concerns the early detection of leaks occurring in small-diameter customers’ connections to water supply networks. An experimental campaign was carried out in a test bed to investigate the sensitivity of Acoustic Emission (AE monitoring to water leaks. Damages were artificially induced on a polyethylene pipe (length 28 m, outer diameter 32 mm at different distances from an AE transducer. Measurements were performed in both unburied and buried pipe conditions. The analysis permitted the identification of a clear correlation between three monitored parameters (namely total Hits, Cumulative Counts and Cumulative Amplitude and the characteristics of the examined leaks.

  4. Leak processing system for valve gland portion

    International Nuclear Information System (INIS)

    Nishino, Masami

    1990-01-01

    When a process fluid for a valve to be checked is at such a normal temperature as during reactor operation, leaked fluid can be detected depending on the temperature increase accompanying the leakage. However, detection is difficult if the temperature of the process fluid for the valve to be checked is low and, if leakage is detected after the reactor start-up, repair has to be applied after the shutdown of the plant. Then, gland leak is detected by detecting the pressure instead of the temperature in the pipeline system and the leak flow rate is calculated based on the pressure. As a result, leakage is detected irrespective of the temperature of the leaked fluid and, for instance, leakage can be detected even in a case where the temperature is not high as in the case of pressure proof test for the pressure vessel before start-up. It can contribute much to the improvement of the plant operation efficiency and can determine the leak flow rate at a high accuracy. (N.H.)

  5. Imaging review of cerebrospinal fluid leaks.

    Science.gov (United States)

    Vemuri, Naga V; Karanam, Lakshmi S P; Manchikanti, Venkatesh; Dandamudi, Srinivas; Puvvada, Sampath K; Vemuri, Vineet K

    2017-01-01

    Cerebrospinal fluid (CSF) leak occurs due to a defect in the dura and skull base. Trauma remains the most common cause of CSF leak; however, a significant number of cases are iatrogenic, and result from a complication of functional endoscopic sinus surgery (FESS). Early diagnosis of CSF leak is of paramount importance to prevent life-threatening complications such as brain abscess and meningitis. Imaging plays a crucial role in the detection and characterization of CSF leaks. Three-dimensional, isotropic, high resolution computed tomography (HRCT) accurately detects the site and size of the bony defect. CT cisternography, though invasive, helps accurately identify the site of CSF leak, especially in the presence of multiple bony defects. Magnetic resonance imaging (MRI) accurately detects CSF leaks and associated complications such as the encephaloceles and meningoceles. In this review, we emphasize the importance and usefulness of 3D T2 DRIVE MR cisternography in localizing CSF leaks. This sequence has the advantages of effective bone and fat suppression, decreased artefacts, faster acquisition times, three-dimensional capability, y and high spatial resolution in addition to providing very bright signal from the CSF.

  6. Imaging review of cerebrospinal fluid leaks

    Directory of Open Access Journals (Sweden)

    Naga V Vemuri

    2017-01-01

    Full Text Available Cerebrospinal fluid (CSF leak occurs due to a defect in the dura and skull base. Trauma remains the most common cause of CSF leak; however, a significant number of cases are iatrogenic, and result from a complication of functional endoscopic sinus surgery (FESS. Early diagnosis of CSF leak is of paramount importance to prevent life-threatening complications such as brain abscess and meningitis. Imaging plays a crucial role in the detection and characterization of CSF leaks. Three-dimensional, isotropic, high resolution computed tomography (HRCT accurately detects the site and size of the bony defect. CT cisternography, though invasive, helps accurately identify the site of CSF leak, especially in the presence of multiple bony defects. Magnetic resonance imaging (MRI accurately detects CSF leaks and associated complications such as the encephaloceles and meningoceles. In this review, we emphasize the importance and usefulness of 3D T2 DRIVE MR cisternography in localizing CSF leaks. This sequence has the advantages of effective bone and fat suppression, decreased artefacts, faster acquisition times, three-dimensional capability, y and high spatial resolution in addition to providing very bright signal from the CSF.

  7. Development of active acoustic method for water leak detection of LMFBR steam generators

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi; Yoshida, Kazuo; Kinoshita, Izumi

    2001-01-01

    In order to prevent the expansion of tube damage and to maintain structural integrity in the steam generators (SGs) of fast breeder reactors (FBRs), it is necessary to detect precisely and immediately the leakage of water from heat transfer tubes. Therefore, an active acoustic method, which detects the sound attenuation due to bubbles generated in the sodium-water reactions, is being developed. In this study, in order to evaluate the detection sensitivity of the active method, the signal processing methods for emitter and receiver and the detection method for leakage are investigated experimentally. In-water experiments performed by using an SG full-sector model that simulates the actual SGs. As an experimental result, the received sound attenuation for 10s was more than 10dB from air bubble injection when injected bubble of 10 l/s (equivalence water leak rate about 10 g/s.) The attenuation of sound are least affected by bubble injection position of heat transfer tubes bunch department. It is clarified that the background noise hardly influenced water leak detection performance as a result of having examined influence of background noise. (author)

  8. Depressurization as a means of leak checking large vacuum vessels

    International Nuclear Information System (INIS)

    Callis, R.W.; Langhorn, A.; Petersen, P.I.; Ward, C.; Wesley, J.

    1985-01-01

    A common problem associated with large vacuum vessels used in magnetic confinement fusion experiments is that leak checking is hampered by the inaccessibility to most of the vacuum vessel surface. This inaccessibility is caused by the close proximity of magnetic coils, diagnostics and, for those vessels that are baked, the need to completely surround the vessel with a thermal insulation blanket. These obstructions reduce the effectiveness of the standard leak checking method of using a mass spectrometer and spraying a search gas such as helium on the vessel exterior. Even when the presence of helium is detected, its entry point into the vessel cannot always be pinpointed. This paper will describe a method of overcoming this problem. By slightly depressurizing the vessel, an influx of helium through the leak is created. The leak site can then be identified by personnel within the vessel using standard sniffing procedures. There are two conditions which make this method of leak checking practical. First, the vessel need only be depressurized 2 psi, thus allowing personnel inside to perform the sniffing operation. Second, the sniffing probe used (Leybold--Heraus ''Quick Test'') could detect a change in helium concentration as small as 100 ppb, which allows for faster scanning of the vessel inferior. Use of this technique to find an elusive 10 -3 Torrxl/s leak in the Doublet III tokamak vacuum vessel will be presented

  9. A mathematical model for leak location and leak area determination in pipeline networks

    Directory of Open Access Journals (Sweden)

    Oyedokun O.I.

    2013-01-01

    Full Text Available Prompt leak location and leak area determination in oil and gas pipeline installations is an indispensable approach to controlling petroleum products wastages in pipes. However, there is an evident lack of literature information on this subject. In this paper, we modelled leak location detection and leak area determination in pipes by applying two methodologies and gave an illustrative example using simulated data with the aid of Matlab. A comparison of these two approaches resulted in an error of 6.24%, suggesting that the closer the leak is to the measurement station, the lower will be the time interval between two successive waves that will pass through the leak and get to the measurement station. The relationship between the pipe area and coefficient of reflection is parabolic. This contribution is valuable to pipeline engineers in the economic control of leaks.

  10. Paravalvular Leak in Structural Heart Disease.

    Science.gov (United States)

    Goel, Kashish; Eleid, Mackram F

    2018-03-06

    This review will summarize the growing importance of diagnosing and managing paravalvular leak associated with surgical and transcatheter valves. The burden of paravalvular leak is increasing; however, advanced imaging techniques and high degree of clinical suspicion are required for diagnosis and management. The latest data from pivotal clinical trials in the field of transcatheter aortic valve replacement suggest that any paravalvular leak greater than mild was associated with worse clinical outcomes. Percutaneous techniques for paravalvular leak closure are now the preferred approach, and surgical repair is reserved for contraindications and unsuccessful procedures. Recent data from studies evaluating paravalvular leak closure outcomes report a greater than 90% success rate with a significant improvement in patient symptoms. Paravalvular leak is a growing problem in the structural heart disease arena. Percutaneous closure is successful in more than 90% of the procedures with a low complication rate.

  11. Process for detecting leak faults using a helium mass spectrometer

    International Nuclear Information System (INIS)

    Divet, Claude; Morin, Claude.

    1977-01-01

    The description is given of a process for detecting very small leak faults putting into communication the outer and inner sides of the wall of a containment, one of these wall sides being in contact with gaseous helium under a pressure of around one torr, the other side being one of the limits of a space pumped down to a residual gas pressure under 10 -3 torr. This space is in communication with the measuring cell of a helium mass spectrometer. This process may be applied to the detection of faults in metal claddings of the fuel rods used in nuclear reactors [fr

  12. Water leaks in sodium-heated fast reactor boilers

    International Nuclear Information System (INIS)

    Hayes, D.J.

    1978-01-01

    Constraints on plant design which may result from considerations of leak behaviour and leak detection limits are briefly considered. The sodium-water interface and reactions, the behaviour of small leaks, hydrogen bubbles and detection methods, including galvanic cell methods, are included. (UK)

  13. VOLUMETRIC LEAK DETECTION IN LARGE UNDERGROUND STORAGE TANKS - VOLUME II: APPENDICES A-E

    Science.gov (United States)

    The program of experiments conducted at Griffiss Air Force Base was devised to expand the understanding of large underground storage tank behavior as it impacts the performance of volumetric leak detection testing. The report addresses three important questions about testing the ...

  14. A study on the leak monitoring of boiler tube in power plants

    International Nuclear Information System (INIS)

    Lee, Sang Guk

    2002-01-01

    Main equipment of thermal power plant, such as boiler and turbine, are designed and manufactured by domestic techniques. But the special equipments monitoring the operation status of these main facilities are still dependent upon foreign technology. Therefore, so as to develop boiler tube leak detection system, we performed studying on manufacturing, installation in site, Acoustic Emission (AE) signal analysis and discrimination etc. As result of studying on boiler tube leak detection using AE, we conformed that diagnosis for boiler tube and computerized their trend management is possible, and also it is expected to contribute to safe operation of power plant facilities

  15. A survey of existing and emerging technologies for external detection of liquid leaks at the Hanford Site

    International Nuclear Information System (INIS)

    Lewis, R.E.; Teel, S.S.

    1994-10-01

    During the history of the Hanford Site, many structures were built that stored and transported liquids used for the production mission; some of these structures are still active. Active structures include underground storage tanks retention basins, and pipes and pipelines. Many of the liquids stored and transported in these structures are potentially hazardous to human health and the environment. Any leakage of liquids from active structures, has the added potential to mobilize contaminants in the unsaturated zone. Therefore, it is beneficial to monitor these structures for leaks. The purpose of tills report is to catalog existing and emerging technologies that have potential for the external monitoring of liquid leaks. The report will focus primarily on the needs at the Hanford Site tank farms that are located in the 200 Areas, but will also be relevant to other Hanford Site facilities. Leak detection systems, both external and internal, are currently used at some Hanford facilities. This report focuses on the detection of leaks as they migrate into the soils surrounding the facilities

  16. Design of an Infrared Imaging System for Robotic Inspection of Gas Leaks in Industrial Environments

    Directory of Open Access Journals (Sweden)

    Ramon Barber

    2015-03-01

    Full Text Available Gas detection can become a critical task in dangerous environments that involve hazardous or contaminant gases, and the use of imaging sensors provides an important tool for leakage location. This paper presents a new design for remote sensing of gas leaks based on infrared (IR imaging techniques. The inspection system uses an uncooled microbolometer detector, operating over a wide spectral bandwidth, that features both low size and low power consumption. This equipment is boarded on a robotic platform, so that wide objects or areas can be scanned. The detection principle is based on the use of active imaging techniques, where the use of external IR illumination enhances the detection limit and allows the proposed system to operate in most cases independently from environmental conditions, unlike passive commercial approaches. To illustrate this concept, a fully radiometric description of the detection problem has been developed; CO2 detection has been demonstrated; and simulations of typical gas detection scenarios have been performed, showing that typical industrial leaks of CH4 are well within the detection limits. The mobile platform where the gas sensing system is going to be implemented is a robot called TurtleBot. The control of the mobile base and of the inspection device is integrated in ROS architecture. The exploration system is based on the technique of Simultaneous Localization and Mapping (SLAM that makes it possible to locate the gas leak in the map.

  17. Small leak damage and protection systems in steam generators

    International Nuclear Information System (INIS)

    Greene, D.A.

    1976-01-01

    A small leak of water into sodium in a liquid metal heated steam generator can cause damage to adjacent tubes, a phenomenon termed wastage. Theories on this phenomenon range from corrosion from sodium water reaction products to erosion by supersonic particles. An alternative approach considers the water injection to form a simple combustion process. Using this approach many aspects of over 250 wastage experiments can be explained both analytically and physically. The U.S. has an extensive technology in the general area of acoustic surveillance. High temperature in-sodium microphones, in-vessel waveguides, and data analysis techniques have been successfully demonstrated in national development programs. This technology has been applied specifically to the development of an acoustic leak detection/location monitor for small leaks in an operating steam generator

  18. Sodium leak detection on large pipes. Heat insulating shells made of silico-aluminate

    International Nuclear Information System (INIS)

    Antonakas, D.; Blanc, R.; Casselman, C.; Malet, J.C.

    1986-05-01

    This report presents an equipment installed on the large secondary pipes of fast reactors, ensuring several functions: support and equilibrium of static and dynamic loads, heat insulator, preheating, and the detection of possible sodium leaks. The research programs associated to the development of the shells are briefly evoked; then, the report deals no longer with the studies on silico-aluminate aging and the detection performance [fr

  19. Advanced conceptual design report: T Plant secondary containment and leak detection upgrades. Project W-259

    International Nuclear Information System (INIS)

    Hookfin, J.D.

    1995-01-01

    The T Plant facilities in the 200-West Area of the Hanford site were constructed in the early 1940s to produce nuclear materials in support of national defense activities. T Plant includes the 271-T facility, the 221-T facility, and several support facilities (eg, 2706-T), utilities, and tanks/piping systems. T Plant has been recommended as the primary interim decontamination facility for the Hanford site. Project W-259 will provide capital upgrades to the T Plant facilities to comply with Federal and State of Washington environmental regulations for secondary containment and leak detection. This document provides an advanced conceptual design concept that complies with functional requirements for the T Plant Secondary Containment and Leak Detection upgrades

  20. Location estimation method of steam leak in pipeline using leakage area analysis

    International Nuclear Information System (INIS)

    Kim, Se Oh; Jeon, Hyeong Seop; Son, Ki Sung; Park, Jong Won

    2016-01-01

    It is important to have a pipeline leak-detection system that determines the presence of a leak and quickly identifies its location. Current leak detection methods use a acoustic emission sensors, microphone arrays, and camera images. Recently, many researchers have been focusing on using cameras for detecting leaks. The advantage of this method is that it can survey a wide area and monitor a pipeline over a long distance. However, conventional methods using camera monitoring are unable to target an exact leak location. In this paper, we propose a method of detecting leak locations using leak-detection results combined with multi-frame analysis. The proposed method is verified by experiment

  1. Location estimation method of steam leak in pipeline using leakage area analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Se Oh; Jeon, Hyeong Seop; Son, Ki Sung [Sae An Engineering Corp., Seoul (Korea, Republic of); Park, Jong Won [Dept. of Information Communications Engineering, Chungnam National University, Daejeon (Korea, Republic of)

    2016-10-15

    It is important to have a pipeline leak-detection system that determines the presence of a leak and quickly identifies its location. Current leak detection methods use a acoustic emission sensors, microphone arrays, and camera images. Recently, many researchers have been focusing on using cameras for detecting leaks. The advantage of this method is that it can survey a wide area and monitor a pipeline over a long distance. However, conventional methods using camera monitoring are unable to target an exact leak location. In this paper, we propose a method of detecting leak locations using leak-detection results combined with multi-frame analysis. The proposed method is verified by experiment.

  2. NDE of stainless steel and on-line leak monitoring of LWRs

    International Nuclear Information System (INIS)

    Kupperman, D.S.; Claytor, T.N.; Mathieson, T.; Prine, D.W.

    1985-10-01

    The GARD/ANL acoustic leak detection system is under evaluation in the laboratory. Results of laboratory tests with simulated acoustic leak signals and acoustic signals from field-induced intergranular stress corrosion cracks (IGSCCs) indicate that cross-correlation techniques can be used to locate the position of a leak. Leaks from a 2-in. ball valve and a flange were studied and compared with leaks from IGSCCs and fatigue cracks. The dependence of acoustic signal on flow rate and frequency for the valve and the flange was comparable to that of fatigue cracks (thermal and mechanical) and different from that of IGSCCs. Two pipe-to-endcap weldments with overlays were examined. Because the amount of cracking in the specimens was limited, the emphasis was on trying understand the nature of crack overcalling. Four 60-mm-thick cast stainless steel plates with microstructures ranging from equiaxed to primarily columnar grains have been examined with ultrasonic waves. 13 refs., 23 figs

  3. Technical bases for leak detection surveillance of waste storage tanks. Revision 1

    International Nuclear Information System (INIS)

    Johnson, M.G.; Badden, J.J.

    1995-01-01

    This document provides the technical bases for specification limits, monitoring frequencies and baselines used for leak detection and intrusion (for single shell tanks only) in all single and double shell radioactive waste storage tanks, waste transfer lines, and most catch tanks and receiver tanks in the waste tank farms and associated areas at Hanford

  4. Active acoustic leak detection for LMFBR steam generator. Pt. 5. Experiment for detection of bubbles using the SG full sector model

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi

    1997-01-01

    In order to prevent the expansion of tube damages and to maintain structural safety in steam generators (SG) of fast breeder reactors (FBR), it is necessary to detect precisely and immediately the leakage of water from tubes of heat exchangers. Therefore, an active acoustic method, which detects the sound attenuation due to bubbles generated in the sodium-water reactions, it being developed. In this paper, the attenuation characteristics of sound attenuated by bubbles and influence of background noise are investigated experimentally by using an SG full sector model (diameter ratio about 1/1, height ratio about 1/7) simulating the actual SG. As an experimental result, the received sound attenuation for ten seconds was more than 10 dB from air bubble injection when injected bubble of 10 l/s (equivalence water leak rate about 10 g/s). The attenuation of sound are least affected by bubble injection position of heat exchanger tube bunch department. And the time was about 25 seconds till the sound attenuation became 10 dB in case of quantity of air bubble 1 l/s (equivalent water leak rate about 1 g/s). It is clarified that the background noise hardly influenced water leak detection performance as a result of having examined influence of background noise. (author)

  5. Detection of leaks for radioactive tracer in marine duct for transport of liquefied petroleum gas

    International Nuclear Information System (INIS)

    Robles P, E. F.; Benitez S, J. A.; Torre O, J. de la; Cruz S, E. de la; Molina, G.; Hernandez C, J. E.; Flores M, J. . e mail: efrp@nuclear.inin.mx

    2008-01-01

    In this work the aplication in the oil industry of the technique of radioactive tracer appears for the detection of internal leaks in a submarine duct that gives service as it lines of receipt of liquefied petroleum gas (Gas LP) located in the Mexican coast of the Pacific Ocean. This system of marine pipe is a consistent arrangement of a duct interior of 0.254 m (10 inches) of nominal diameter (N.D.) of steel to the carbon for cryogenic service ASTM A 333, Grade 6, schedule 30, isolated thermally with foam of polyurethane and shielding in a steel tube to the carbon ASTM A 53 Grade A, of 0.508 m (20 inches) N. D., schedule 20, which is recovered by a ballast encircling of concrete of 0.0508 m (2 inches) of thickness, reinforced with mesh metallic, and that 1315 m runs on the marine stratum to a maximum depth of 12.5 m. For the detection of leaks by radiotracer it was used as tracer the radioactive isotope La-140 produced in the TRIGA Mark III Experimental Reactor of the National Institute of Nuclear Research, starting from stable lanthanum nitrate (La(NO 3 ) 3 6H 2 O), with an activity of 100 mCi, the one which after having been made logistics tasks, given very particular sea maneuvers and due to the conditions of the work place, in the interior tube was injected in two subsequent stages to cover both duct senses; from earth and from the marine end respectively, there being used fresh water like transport way and submergible sodium iodide detectors (NaI) for the rake of the La-140. At the end of the journeys of pursuit of the radiotracer, it was determine the presence of three leaks points located in the break area of the marine surf to 360 m, 450 m and 495 m of distance of a reference point located in the beach section named Trap of Devils. (Author)

  6. Leak Detection of High Pressure Feedwater Heater Using Empirical Models

    International Nuclear Information System (INIS)

    Lee, Song Kyu; Kim, Eun Kee; Heo, Gyun Young; An, Sang Ha

    2009-01-01

    Even small leak from tube side or pass partition within the high pressure feedwater heater (HPFWH) causes a significant deficiency in its performance. Plant operation under the HPFWH leak condition for long time will result in cost increase. Tube side leak within HPFWH can produce the high velocity jet of water and it can cause neighboring tube failures. However, most of plants are being operated without any information for internal leaks of HPFWH, even though it is prone to be damaged under high temperature and high pressure operating conditions. Leaks from tubes and/or pass partition of HPFWH occurred in many nuclear power plants, for example, Mihama PS-2, Takahama PS-2 and Point Beach Nuclear Plant Unit 1. If the internal leaks of HPFWH are monitored, the cost can be reduced by inexpensive repairs relative to loss in performance and moreover plant shutdown as well as further tube damages can be prevented

  7. Field tests and commercialization of natural gas leak detectors

    Energy Technology Data Exchange (ETDEWEB)

    Choi, D S; Jeon, J S; Kim, K D; Cho, Y A [R and D Center, Korea Gas Corporation, Ansan (Korea)

    1999-09-01

    Objectives - (1) fields test of industrial gas leak detection monitoring system. (2) commericialization of residential gas leak detector. Contents - (1) five sets of gas leak detection monitoring system were installed at natural gas transmition facilities and tested long term stability and their performance. (2) improved residential gas leak detector was commercialised. Expected benefits and application fields - (1) contribution to the improvement of domestic gas sensor technology. (2) localization of fabrication technology for gas leak detectors. 23 refs., 126 figs., 37 tabs.

  8. Report: Suitability of Leak Detection Technology for Use In Ethanol-Blended Fuel Service

    Science.gov (United States)

    As the use of biofuels has increased in the last decade, there has been a level of concern over the effect that ethanol blends have on the material compatibility and operability of existing infrastructure. The focus of this research is to determine whether leak detection (LD) te...

  9. Ammonia Leak Locator Study

    Science.gov (United States)

    Dodge, Franklin T.; Wuest, Martin P.; Deffenbaugh, Danny M.

    1995-01-01

    The thermal control system of International Space Station Alpha will use liquid ammonia as the heat exchange fluid. It is expected that small leaks (of the order perhaps of one pound of ammonia per day) may develop in the lines transporting the ammonia to the various facilities as well as in the heat exchange equipment. Such leaks must be detected and located before the supply of ammonia becomes critically low. For that reason, NASA-JSC has a program underway to evaluate instruments that can detect and locate ultra-small concentrations of ammonia in a high vacuum environment. To be useful, the instrument must be portable and small enough that an astronaut can easily handle it during extravehicular activity. An additional complication in the design of the instrument is that the environment immediately surrounding ISSA will contain small concentrations of many other gases from venting of onboard experiments as well as from other kinds of leaks. These other vapors include water, cabin air, CO2, CO, argon, N2, and ethylene glycol. Altogether, this local environment might have a pressure of the order of 10(exp -7) to 10(exp -6) torr. Southwest Research Institute (SwRI) was contracted by NASA-JSC to provide support to NASA-JSC and its prime contractors in evaluating ammonia-location instruments and to make a preliminary trade study of the advantages and limitations of potential instruments. The present effort builds upon an earlier SwRI study to evaluate ammonia leak detection instruments [Jolly and Deffenbaugh]. The objectives of the present effort include: (1) Estimate the characteristics of representative ammonia leaks; (2) Evaluate the baseline instrument in the light of the estimated ammonia leak characteristics; (3) Propose alternative instrument concepts; and (4) Conduct a trade study of the proposed alternative concepts and recommend promising instruments. The baseline leak-location instrument selected by NASA-JSC was an ion gauge.

  10. Leak detector for reactor pressure vessel

    International Nuclear Information System (INIS)

    Morimoto, Mikio.

    1991-01-01

    A branched pipe is disposed to a leak off pipeline led from a flange surface which connects the main body and the upper lid of a reactor pressure vessel. An exhaust pump is disposed to the branched pipe and a moisture gage is disposed on the side of the exhaustion and a dry air supplier is connected to the branched pipe. Upon conducting a pressure-proof leak test for the reactor pressure vessel, the exhaust pump is operated and an electromagnet valve disposed at the upstream of the dry air supplier is opened and closed repeatedly. The humidity of air sucked by the exhaust pump is detected by the moisture gage. If leaks should be caused in the joining surface of the flange, leaked water is diffused as steams. Accordingly, occurrence of leak can be detected instantly based on the comparison with the moisture level of the dry air as a standard. In this way, a leak test can be conducted reliably in a short period of time with no change of for the reactor pressure container itself. (I.N.)

  11. Detection and location of leaking TRIGA fuel elements

    International Nuclear Information System (INIS)

    Bouchey, G.D.; Gage, S.J.

    1970-01-01

    Several TRIGA facilities have experienced difficulty resulting from cladding failures of aluminum clad TRIGA fuel elements. Recently, at the University of Texas at Austin reactor facility, fission product releases were observed during 250 kW operation and were attributed to a leaking fuel element. A rather extensive testing program has been undertaken to locate the faulty element. The used sniffer device is described, which provides a quick, easily constructed, and extremely sensitive means of locating leaking fuel elements. The difficulty at The University of Texas was compounded by extremely low levels and the sporadic nature of the releases. However, in the more typical situation, in which a faulty element consistently releases relatively large quantities of fission gas, such a device should locate the leak with little difficulty

  12. Steam generators of Phenix: Measurement of the hydrogen concentration in sodium for detecting water leaks in the steam generator tubes

    International Nuclear Information System (INIS)

    Cambillard, E.; Lacroix, A.; Langlois, J.; Viala, J.

    1975-01-01

    The Phenix secondary circuits are provided with measurement systems of hydrogen concentration in sodium, that allow for the detection of possible water leaks in steam generators and the location of a faulty module. A measurement device consists of : a detector with nickel membranes of 0, 3 mm wall thickness, an ion pump with a 200 l/s flow rate, a quadrupole mass spectrometer and a calibrated hydrogen leak. The temperature correction is made automatically. The main tests carried out on the leak detection systems are reported. Since the first system operation (October 24, 1973), the measurements allowed us to obtain the hydrogen diffusion rates through the steam generator tube walls. (author)

  13. The leakage problem in vacuum system. Realization of a mass spectrometer detecting leaks

    International Nuclear Information System (INIS)

    Geller, R.

    1954-11-01

    In the first part of this paper we consider the problem of leaks in vacuum systems, and their detection. We consider in particular the method of detection by means of a helium spectrometer. The second part deals with the experimental set p. The analyser and the ion source have been studied in great detail, and we have also discussed the technological and mechanical aspects of the apparatus and its performances. (author) [fr

  14. Hierarchical Leak Detection and Localization Method in Natural Gas Pipeline Monitoring Sensor Networks

    OpenAIRE

    Ning Yu; Renjian Feng; Jiangwen Wan; Yinfeng Wu; Yang Yu

    2011-01-01

    In light of the problems of low recognition efficiency, high false rates and poor localization accuracy in traditional pipeline security detection technology, this paper proposes a type of hierarchical leak detection and localization method for use in natural gas pipeline monitoring sensor networks. In the signal preprocessing phase, original monitoring signals are dealt with by wavelet transform technology to extract the single mode signals as well as characteristic parameters. In the initia...

  15. Imaging review of cerebrospinal fluid leaks

    OpenAIRE

    Naga V Vemuri; Lakshmi S P Karanam; Venkatesh Manchikanti; Srinivas Dandamudi; Sampath K Puvvada; Vineet K Vemuri

    2017-01-01

    Cerebrospinal fluid (CSF) leak occurs due to a defect in the dura and skull base. Trauma remains the most common cause of CSF leak; however, a significant number of cases are iatrogenic, and result from a complication of functional endoscopic sinus surgery (FESS). Early diagnosis of CSF leak is of paramount importance to prevent life-threatening complications such as brain abscess and meningitis. Imaging plays a crucial role in the detection and characterization of CSF leaks. Three-dimensiona...

  16. Prioritizing Test Cases for Memory Leaks in Android Applications

    Institute of Scientific and Technical Information of China (English)

    Ju Qian; Di Zhou

    2016-01-01

    Mobile applications usually can only access limited amount of memory. Improper use of the memory can cause memory leaks, which may lead to performance slowdowns or even cause applications to be unexpectedly killed. Although a large body of research has been devoted into the memory leak diagnosing techniques after leaks have been discovered, it is still challenging to find out the memory leak phenomena at first. Testing is the most widely used technique for failure discovery. However, traditional testing techniques are not directed for the discovery of memory leaks. They may spend lots of time on testing unlikely leaking executions and therefore can be inefficient. To address the problem, we propose a novel approach to prioritize test cases according to their likelihood to cause memory leaks in a given test suite. It firstly builds a prediction model to determine whether each test can potentially lead to memory leaks based on machine learning on selected code features. Then, for each input test case, we partly run it to get its code features and predict its likelihood to cause leaks. The most suspicious test cases will be suggested to run at first in order to reveal memory leak faults as soon as possible. Experimental evaluation on several Android applications shows that our approach is effective.

  17. Evaluation of methodologies for the calculation of leak rates for pressure retaining components with crack-like leaks

    International Nuclear Information System (INIS)

    Sievers, Juergen; Heckmann, Klaus; Blaesius, Christoph

    2015-06-01

    For the demonstration of break preclusion for pressure retaining components in nuclear power plants, the nuclear safety standard KTA 3206 determines also the requirements for the leak-before-break verification. For this procedure, it has to be ensured that a wall-penetrating crack is subcritical with respect to instable growth, and that the resulting leakage under stationary operation conditions can be detected by a leak detection system. Within the scope of the project 3613R01332 analyses with respect to conservative estimates of the leak rates in case of detections regarding break preclusion were performed by means of leak rate models being available at GRS. For this purpose, conservative assumptions in the procedure were quantified by comparative calculations concerning selected leak rate experiments and the requirements regarding the determination of leak rates indicated in the KTA 3206 were verified and specified. Moreover, the models were extended and relevant recommendations for the calculation procedure were developed. During the investigations of leak rate tests the calculation methods were validated, qualified by means of both examples indicated in KTA 3206 and applied to a postulated leak accident in the cooling circuit of a PWR. For the calculation of leak rates several simplified solution methods which are included in the GRS program WinLeck were applied, and for the simulation of a leak accident the large-scale programs ANSYS Mechanical and ATHLET (thermohydraulics program developed by GRS) were used. When applying simplified methods for the calculation of leak rates using the limiting curve for the friction factor which has been derived during the project and which is included in the KTA 3206 attention has to be paid to the fact that in case of small flow lengths the entrance loss can dominate compared to the friction loss. However, the available data do not suffice in order to make a quantitative statement with respect to limits of applicability

  18. Detailed leak detection test plan and schedule for the Oak Ridge National Laboratory LLLW active tanks

    International Nuclear Information System (INIS)

    Douglas, D.G.; Maresca, J.W. Jr.

    1993-03-01

    This document provides a detailed leak detection test plan and schedule for leak testing many of the tanks that comprise the active portion of the liquid low-level waste (LLLW) system at the Oak Ridge National Laboratory (ORNL). This plan was prepared in response to the requirements of the Federal Facility Agreement (FFA) between the US Department of Energy (DOE) and two other agencies, the US Environmental Protection Agency (EPA) and the Tennessee Department of Environment and Conservation (TDEC)

  19. Assessment of leak detection capability of Candu 6 annulus gas system using moisture injection tests

    International Nuclear Information System (INIS)

    Nho, Ki Man; Kim, Wang Bae

    1998-01-01

    The Candu 6 reactor assembly consists of an array of 380 pressure tubes, which are installed horizontally in a large cylindrical vessel, the Calandria, containing the low pressure heavy water moderator. The pressure tube is located inside calandria tube and the annulus between these tubes, which forms a closed loop with CO 2 gas recirculating, is called the Annulus Gas System (AGS). It is designed to give an alarm to the operator even for a small pressure tube leak by a very sensitive dew point meter so that he can take a preventive action for the pressure tbe rupture incident. To judge whether the operator action time is enough or not in the design of Wolsung 2, 3, and 4, the Leak Before Break (LBB) assessment is required for the analysis of the pressure tube failure accident. In order to provide the required data for the LBB assessment of Wolsung Units 2, 3, 4, a series of leak detection capability tests was performed by injecting controlled rates of heavy water vapour. The data of increased dew point and rates of rise were measured to determine the alarm set point for dew point rate of rise of Wolsung Unit 2. It was found that the response of the dew point depends on the moisture injection rate, CO 2 gas flow rate and the leak location. The test showed that Candu 6 AGS can detect the very small leaks less than few g/hr and dew point rate of rise alarm can be the most reliable alarm signal to warn the operator. Considering the present results, the first response time of dew point to the AGS CO 2 flow rate is approximated. (author)

  20. Rio Vista gas leak study: Belleaire Gas Field, California

    International Nuclear Information System (INIS)

    Wilkey, P.L.

    1992-08-01

    The Rio Vista gas leak study evaluated methods for remotely sensing gas leaks from buried pipelines and developed methods to elucidate methane transport and microbial oxidation in soils. Remote-sensing methods were evaluated by singing gas leaks along an abandoned Pacific Gas and Electric (PG ampersand E) gas field collection line in northern California and applying surface-based and airborne remote-sensing techniques in the field, including thermal imaging, laser imaging, and multispectral imagery. The remote-sensing techniques exhibited limitations in range and in their ability to correlate with ground truth data. To elucidate methane transport and microbial oxidation in soils, a study of a controlled leak permitted field testing of methods so that such processes could be monitored and evaluated. Monitoring and evaluation techniques included (1) field measurement of soil-gas concentrations, temperatures, and pressures; (2) laboratory measurement of soil physical/chemical properties and activity of methane-oxidizing microorganisms by means of field samples; and (3) development of a preliminary numerical analysis technique for combined soil-gas transport/methane oxidation. Soil-gas concentrations at various depths responded rapidly to the high rate of gas leakage. The number of methane-oxidizing microorganisms in site soils rapidly increased when the gas leak was initiated and decreased after the leak was terminated. The preliminary field, laboratory, and numerical analysis techniques tested for this study of a controlled gas leak could be successfully applied to future studies of gas leaks. Because soil-gas movement is rapid and temporally variable, the use of several complementary techniques that permit generalization of site-specific results is favored

  1. PFR evaporator leak

    International Nuclear Information System (INIS)

    Smedley, J.A.

    1975-01-01

    PFR has three heat removal circuits each one having an evaporator, superheater, reheater; all separate units. The status of the system was that circuit No 3 was steaming with 10 MW thermal nuclear power; No 1 circuit was filled with sodium but with the evaporator awaiting modification to cure gas entrainment problems already reported. The leak was in No 2 circuit and was located in the evaporator unit. The evaporator is rated at 120 M thermal at full power and as such is a large unit. The circuit was filled with both sodium and water for the first time three weeks before the conference so it was recent history being reported and therefore any figures quoted should be taken as indicative only. The history of the steam generator was that it was built at works to a very high standard and underwent all the usual tests of strength, inspection of welds and helium leak testing. The steam generator is of U tube design with a tube plate to which the boiler tubes are welded, with all the welds in one of two gas spaces. The inlet and outlet sides are separated by a baffle and the salient features are illustrated in the attached figure. The unit achieved a leak tightness better than the detection limit in the helium leak test at works. This limit was assessed as being less than an equivalent leak of 10 -6 g/s water under steam generator service conditions. However even though all the steam generator units passed this test at works a further test was carried out when the circuits had been completed. The test was carried out during commissioning after sodium filling and with the units hot. The method was to introduce a mixture of helium/ argon at 500 pounds/square inch into the water side of the steam generators and measure the helium concentration in the sodium side gas spaces of the circuit. The test lasted many days and under these conditions the sensitivity is such that a leak equivalent to somewhere between 10 -7 to 10 -6 g/s equivalent water leak could be detected, i

  2. PFR evaporator leak

    Energy Technology Data Exchange (ETDEWEB)

    Smedley, J A

    1975-07-01

    PFR has three heat removal circuits each one having an evaporator, superheater, reheater; all separate units. The status of the system was that circuit No 3 was steaming with 10 MW thermal nuclear power; No 1 circuit was filled with sodium but with the evaporator awaiting modification to cure gas entrainment problems already reported. The leak was in No 2 circuit and was located in the evaporator unit. The evaporator is rated at 120 M thermal at full power and as such is a large unit. The circuit was filled with both sodium and water for the first time three weeks before the conference so it was recent history being reported and therefore any figures quoted should be taken as indicative only. The history of the steam generator was that it was built at works to a very high standard and underwent all the usual tests of strength, inspection of welds and helium leak testing. The steam generator is of U tube design with a tube plate to which the boiler tubes are welded, with all the welds in one of two gas spaces. The inlet and outlet sides are separated by a baffle and the salient features are illustrated in the attached figure. The unit achieved a leak tightness better than the detection limit in the helium leak test at works. This limit was assessed as being less than an equivalent leak of 10{sup -6} g/s water under steam generator service conditions. However even though all the steam generator units passed this test at works a further test was carried out when the circuits had been completed. The test was carried out during commissioning after sodium filling and with the units hot. The method was to introduce a mixture of helium/ argon at 500 pounds/square inch into the water side of the steam generators and measure the helium concentration in the sodium side gas spaces of the circuit. The test lasted many days and under these conditions the sensitivity is such that a leak equivalent to somewhere between 10{sup -7} to 10{sup -6} g/s equivalent water leak could be

  3. Development of evaluation method of long-term confinement performance for canister. Part 1. Fundamental study of analyses method for helium leak detection

    International Nuclear Information System (INIS)

    Takeda, Hirofumi; Toriu, Daisuke; Ushijima, Satoru

    2014-01-01

    The storage management of spent nuclear fuel for ageing degradation is becoming a global issue, so we researched the present status and measures of the management in each country. In particular, for the concrete cask storage, a leak detecting method that detects the leak from the change in canister surface temperature has been proposed. We performed thermal hydraulics analysis to clarify the phenomenon and to work toward practical use of the detecting method. For analyzing the leak phenomenon with high accuracy, it is necessary to stably solve the low-Mach number flow problem considering compressibility of gas. Therefore, we originally modified the conventional compressible flow solution method and proposed a new method which is applicable to thermo-hydraulics phenomenon and satisfies the mass conservation law with high accuracy. For the cavity natural convection analysis, the mass conservation in a calculating area was satisfied with high accuracy. As for the analysis of leak from the cavity, a helium leak phenomenon could be calculated stably by using the proposed method. The pressure in the cavity and the change of the mass could be also analyzed validly. As for the temperature distribution in the cavity, it was confirmed that the temperature changes before and after the leak. (author)

  4. Water-soluble upper GI based on clinical findings is reliable to detect anastomotic leaks after laparoscopic gastric bypass.

    Science.gov (United States)

    Katasani, V G; Leeth, R R; Tishler, D S; Leath, T D; Roy, B P; Canon, C L; Vickers, S M; Clements, R H

    2005-11-01

    Anastomotic leak after laparoscopic Roux-en-Y gastric bypass (LGB) is a major complication that must be recognized and treated early for best results. There is controversy in the literature regarding the reliability of upper GI series (UGI) in diagnosing leaks. LGB was performed in patients meeting NIH criteria for the surgical treatment of morbid obesity. All leaks identified at the time of surgery were repaired with suture and retested. Drains were placed at the surgeon's discretion. Postoperatively, UGI was performed by an experienced radiologist if there was a clinical suspicion of leak. From September 2001 until October 2004, a total of 553 patients (age 40.4 +/- 9.2 years, BMI 48.6 +/- 7.2) underwent LGB at UAB. Seventy-eight per cent (431 of 553) of patients had no clinical evidence suggesting anastomotic leak and were managed expectantly. Twenty-two per cent (122 of 553) of patients met at least one inclusion criteria for leak and underwent UGI. Four of 122 patients (3.2%) had a leak, two from anastomosis and two from the perforation of the stapled end of the Roux limb. No patient returned to the operating room without a positive UGI. High clinical suspicion and selectively performed UGI based on clinical evidence is reliable in detecting leaks.

  5. Analysis methods for evaluating leak-before-break in U-tube steam generators

    International Nuclear Information System (INIS)

    Griesbach, T.; Cipolla, R.

    1985-01-01

    In recent years, there has been an increased incidence of cracking in steam generator tubes. As a result, there has been increased effort in assuring that cracks in steam generator tubes will leak well in advance of significant loss in structural integrity. Demonstrating a leak-before-break condition is an integrated analysis process that utilizes several engineering disciplines, specifically, materials engineering, fracture mechanics, stress analysis, and fluid mechanics. The output from a leak-before-break assessment is typically depicted in terms of available margins against failure and measurable or detectable leak rate. In this paper, the analysis methods for performing a leak-before-break analysis for the U-tubes of a recirculating steam generator are presented. The results from generic analysis for the first row U-tubes illustrates the analysis techniques. Because of realistic input values used herein, these results also suggest that large leak rates are possible from cracks in U-bend regions, yet these cracks are small relative to their critical size for failure. Hence, orderly shutdowns can be completed prior to the point when tube bursting is of concern

  6. New methods for leaks detection and localisation using acoustic emission; Nouvelles methodes de detection et de localisation de fuites par emission acoustique

    Energy Technology Data Exchange (ETDEWEB)

    Boulanger, P

    1993-12-08

    Real time monitoring of Pressurized Water nuclear Reactor secondary coolant system tends to integrate digital processing machines. In this context, the method of acoustic emission seems to exhibit good performances. Its principle is based on passive listening of noises emitted by local micro-displacements inside a material under stress which propagate as elastic waves. The lack of a priori knowledge on leak signals leads us to go deeper into understanding flow induced noise generation. Our studies are conducted using a simple leak model depending on the geometry and the king of flow inside the slit. Detection and localization problems are formulated according to the maximum likelihood principle. For detection, the methods using a indicator of similarity (correlation, higher order correlation) seems to give better results than classical ones (rms value, envelope, filter banks). For leaks location, a large panel of classical (generalized inter-correlation) and innovative (convolution, adaptative, higher order statistics) methods of time delay estimation are presented. The last part deals with the applications of higher order statistics. The analysis of higher order estimators of a non linear non Gaussian stochastic process family, the improvement of non linear prediction performances and the optimal-order choice problem are addressed in simple analytic cases. At last, possible applications to leak signals analysis are pointed out. (authors).264 refs., 7 annexes.

  7. Detailed leak detection test plan and schedule for the Oak Ridge National Laboratory LLLW active pipelines

    International Nuclear Information System (INIS)

    Douglas, D.G.; Starr, J.W.; Juliano, T.M.; Maresca, J.W. Jr.

    1993-09-01

    This document provides a detailed leak detection test plan and schedule for leak testing many of the pipelines that comprise the active portion of the liquid low-level waste (LLLW) system at the Oak Ridge National Laboratory (ORNL). This plan was prepared in response to the requirements of the Federal Facility Agreement (FFA) between the US Department of Energy (DOE) and two other agencies, the US Environmental Protection Agency (EPA) and the Tennessee Department of Environment and Conservation (TDEC). The LLLW system is an interconnected complex of tanks and pipelines. The FFA distinguishes four categories of tank and pipeline systems within this complex: new systems (Category A), doubly contained systems (Category B), singly contained systems (Category C), and inactive systems (Category D). The FFA specifically requires leak testing of the Category C systems. This plan and schedule addresses leak testing of the Category C pipelines and those doubly contained pipelines that do not fully meet the requirements for secondary containment as listed in the FFA

  8. Engineering Sensitivity Improvement of Helium Mass Spectrometer Leak Detection System by Means Global Hard Vacuum Test

    International Nuclear Information System (INIS)

    Sigit Asmara Santa

    2006-01-01

    The engineering sensitivity improvement of Helium mass spectrometer leak detection using global hard vacuum test configuration has been done. The purpose of this work is to enhance the sensitivity of the current leak detection of pressurized method (sniffer method) with the sensitivity of 10 -3 ∼ 10 -5 std cm 3 /s, to the global hard vacuum test configuration method which can be achieved of up to 10 -8 std cm 3 /s. The goal of this research and development is to obtain a Helium leak test configuration which is suitable and can be used as routine bases in the quality control tests of FPM capsule and AgInCd safety control rod products. The result is an additional instrumented vacuum tube connected with conventional Helium mass spectrometer. The pressure and temperature of the test object during the leak measurement are simulated by means of a 4.1 kW capacity heater and Helium injection to test object, respectively. The addition of auxiliary mechanical vacuum pump of 2.4 l/s pumping speed which is directly connected to the vacuum tube, will reduce 86 % of evacuation time. The reduction of the measured sensitivity due to the auxiliary mechanical vacuum pump can be overcome by shutting off the pump soon after Helium mass spectrometer reaches its operating pressure condition. (author)

  9. Likelihood of Brine and CO2 Leak Detection using Magnetotellurics and Electrical Resistivity Tomography Methods

    Energy Technology Data Exchange (ETDEWEB)

    Yang, X. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Buscheck, T. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Mansoor, K. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Carroll, S. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-09-11

    The US DOE National Risk Assessment Partnership (NRAP), funded through the Office of Fossil Energy and NETL, is developing methods to evaluate the effectiveness of monitoring techniques to detect brine and CO2 leakage from legacy wells into underground sources of drinking water (USDW) overlying a CO2 storage reservoir. As part of the NRAP Strategic Monitoring group, we have generated 140 simulations of aquifer impact data based on the Kimberlina site in California’s southern San Joaquin Basin, Kimberlina Rev. 1.1. CO2 buoyancy allows some of the stored CO2 to reach shallower permeable zones and is detectable with surface geophysical sensors. We are using this simulated data set to evaluate effectiveness of electrical resistivity tomography (ERT) and magnetotellurics (MT) for leak detection. The evaluation of additional monitoring methods such as pressure, seismic and gravity is underway through a multi-lab collaboration.

  10. Development of sodium leak detection technology using laser resonance ionization mass spectrometry. Design and functional test using prototype sodium detection system

    International Nuclear Information System (INIS)

    Aoyama, Takafumi; Ito, Chikara; Harano, Hideki; Okazaki, Koki; Watanabe, Kenichi; Iguchi, Tetsuo

    2009-01-01

    In a sodium-cooled fast reactor, highly sensitive technology is required to detect small amounts of sodium leaking from the cooling system piping or components. The conventional sodium leak detectors have a fundamental difficulty in improving the detection sensitivity for a sodium leak because of the presence of salinity ( 23 NaCl) in the atmosphere around the components and piping of cooling systems. In order to overcome this problem, an innovative technology has been developed to selectively detect the radioactive sodium ( 22 Na) produced by a neutron reaction in the primary cooling system using Laser Resonance Ionization Mass Spectrometry (RIMS). In this method, sodium ions produced with the two processes of (1) atomization of sodium aerosols and (2) resonance ionization of sodium atom, are detected selectively using a time-of-flight mass spectrometer. The 22 Na can be distinguished from the stable isotope ( 23 Na) by mass spectrometry, which is the advantage of RIMS comparing to the other methods. The design and the construction of the prototype system based on fundamental experiments are shown in the paper. The aerodynamic lens was newly introduced, which can transfer aerosols at atmospheric pressure into a vacuum chamber while increasing the aerosol density at the same time. Furthermore, the ionization process was applied by using the external electric field after resonance exciting from the ground level to the Rydberg level in order to increase the ionization efficiency. The preliminary test results using the stable isotope ( 23 Na) showed that prototype system could easily detect sodium aerosol of 100 ppb, equivalent to the sensitivity of the conventional detectors. (author)

  11. Fluid pipeline system leak detection based on neural network and pattern recognition

    International Nuclear Information System (INIS)

    Tang Xiujia

    1998-01-01

    The mechanism of the stress wave propagation along the pipeline system of NPP, caused by turbulent ejection from pipeline leakage, is researched. A series of characteristic index are described in time domain or frequency domain, and compress numerical algorithm is developed for original data compression. A back propagation neural networks (BPNN) with the input matrix composed by stress wave characteristics in time domain or frequency domain is first proposed to classify various situations of the pipeline, in order to detect the leakage in the fluid flow pipelines. The capability of the new method had been demonstrated by experiments and finally used to design a handy instrument for the pipeline leakage detection. Usually a pipeline system has many inner branches and often in adjusting dynamic condition, it is difficult for traditional pipeline diagnosis facilities to identify the difference between inner pipeline operation and pipeline fault. The author first proposed pipeline wave propagation identification by pattern recognition to diagnose pipeline leak. A series of pattern primitives such as peaks, valleys, horizon lines, capstan peaks, dominant relations, slave relations, etc., are used to extract features of the negative pressure wave form. The context-free grammar of symbolic representation of the negative wave form is used, and a negative wave form parsing system with application to structural pattern recognition based on the representation is first proposed to detect and localize leaks of the fluid pipelines

  12. High level helium leak testing methods developed at ICSI Rm. Valcea

    International Nuclear Information System (INIS)

    Saros, Gili; Armeanu, Adrian; Saros, Irina; Ciortea, Constantin

    2007-01-01

    Full text: Helium leak detection is one of the most widely used methods of nondestructive testing in use today. In principle two methods are applied for leak testing and localization of leaks, the 'Vacuum method' and the 'Overpressure method'. In case of the 'Vacuum method' the object to be examined for leaks is evacuated and filled instead with Helium. The gas penetrates through any leaks found in the object and is detected by the leak test instrument. In case of the 'Overpressure method' the object to be examined for leaks is filled with Helium, under slight overpressure. The gas escapes through any leaks present and it is detected by a detector probe. This detector probe sometimes called a 'sniffer' acting as a gas sampling probe. Varian 979 Helium Leak Detector has a built-in turbo pump and an externally mounted dry forepump located below the system. The leak detector is configured for the evacuation type leak testing. In this case, the vacuum system under test is evacuated by the leak detector. Helium is then sprayed on the outside of the vacuum system and is pumped into the leak detector if a leak is present. The leak detector is capable to detect leaks down to 10 -9 atm-cc/sec range. The Specton 300E is a strong, rugged leak detector designed to operate in dirty industrial conditions as well as clean research areas. A number of applications are mentioned: - Generators; - Buried Pipelines; - Chemical and power plants; - Vacuum furnace installations; - Heat Exchangers; - Tank Floors; - Nuclear research centers; - Refrigeration installations; - Any type of industrial vacuum system. (authors)

  13. Low Level Leaks

    Science.gov (United States)

    1998-01-01

    NASA has transferred the improved portable leak detector technology to UE Systems, Inc.. This instrument was developed to detect leaks in fluid systems of critical launch and ground support equipment. This system incorporates innovative electronic circuitry, improved transducers, collecting horns, and contact sensors that provide a much higher degree of reliability, sensitivity and versatility over previously used systems. Potential commercial uses are pipelines, underground utilities, air-conditioning systems, petrochemical systems, aerospace, power transmission lines and medical devices.

  14. Device for detecting the water leak within a feedwater nozzle in water cooled reactors

    International Nuclear Information System (INIS)

    Hattori, Tsunekazu.

    1984-01-01

    Purpose: To enable exact recognition and detection for the state of water leak. Constitution: The detection device comprises a thermocouple disposed to the outer surface of a feedwater nozzle, a distortion meter for detecting the change in the outer diameter of a nozzle and an acoustic emission generator disposed to the inside of the nozzle for generating a signal upon temperature change. These sensors previously monitor the states during normal operation, and thus detect the change in each of the states upon occurrence of water leakage to issue an alarm. (Kamimura, M.)

  15. Application of leak-before-break criteria to pressurized water reactors

    International Nuclear Information System (INIS)

    Roege, P.; Day, B.; Beckjord, E.; Golay, M.

    1986-01-01

    The possibility of consequential damage to safety-related systems or components after postulated pipe breaks in Light Water Reactors has led to the installation of pipe restraints capable of withstanding the loads in such an accident. These restraints are a significant part of initial capital cost, and because of their size and location, impede plant maintenance. The Piping Review Committee of the U.S. Nuclear Regulatory Commission has concluded that, subject to fulfillment of certain criteria, the pipe restraints for pressurized water reactor main coolant piping are not necessary, because the failure mode of this piping is such that it will leak before it will break, and the leakage of reactor coolant is large enough to detect. In this study, we examine the piping systems of a 4-loop 1,150 MWe pressurized water reactor, determining the crack size that would be stable from a fracture mechanics point of view, and the range of leak rates that would ensue. We then consider the sensitivity of conventional leak detection systems, and find that pipe sizes down to 45 cm in diameter would meet the leak-before-break criteria. Improvements in the sensitivity of conventional leak detectors would extend this range down to pipe sizes down to the range of 20 - 45 cm in diameter. The development of local leak detection systems which would respond to leaks in compartments or confined areas would make it possible to apply the criteria to sizes as low as 10 - 20 cm in diameter, which appear to be the limit of the net cost savings of eliminating pipe restraints and adding additional leak detection instrumentation. Extending the leak-before-break concept into this smallest pipe range may require improved precision in crack definition, flow modeling, and leak detection. Better detection of leaks may also require use of new detection methods coupled to novel approaches to piping system design. (J.P.N.)

  16. Acoustic leak detector in Monju steam generator

    International Nuclear Information System (INIS)

    Wachi, E.; Inoue, T.

    1990-01-01

    Acoustic leak detectors are equipped with the Monju steam generators for one of the R and D activities, which are the same type of the detectors developed in the PNC 50MW Steam Generator Test Facility. Although they are an additional leak detection system to the regular one in Monju SG, they would also detect the intermediate or large leaks of the SG tube failures. The extrapolation method of a background noise analysis is expected to be verified by Monju SG data. (author). 4 figs

  17. 40 CFR 63.769 - Equipment leak standards.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Equipment leak standards. 63.769... § 63.769 Equipment leak standards. (a) This section applies to equipment subject to this subpart and... release to detect leaks, except under the following conditions. (i) The owner or operator has obtained...

  18. Color Changing Material for Hydrogen Leak Detection

    Science.gov (United States)

    Victor, Megan E.

    2014-01-01

    Kennedy Space Center scientists developed a hydrogen leak sensor utilizing a combination of chemochromic pigment and polymer that can be molded or fiber spun into rigid or flexible shapes such as tape. The sensor turns a dark color when exposed to hydrogen gas. This sensor has proven to be very effective for pinpointing the exact location of leaks in hydrogen gas lines and fittings at launch pads. Kennedy Space Center exclusively licensed this technology to the University of Central Florida (UCF), who also holds patents that are complimentary to KSC's. UCF has bundled the patents and exclusively licensed the portfolio to HySense Technology LLC, a startup company founded by a UCF professor who supports the UCF Florida Solar Energy Center (FSEC). HySense has fully developed its product (known as Intellipigment"TM"), and currently has five commercial customers. The company recently won the $100,000 first-place award at the CAT5 innovation competition at the Innovation Concourse of the Southeast: Safety & Manufacturing event in Orlando, FL. Commercial production and sales of this technology by HySense Technology will make this leak sensor widely available for use by NASA, DoD, and industries that utilize hydrogen gas.

  19. The effects of resonances on time delay estimation for water leak detection in plastic pipes

    Science.gov (United States)

    Almeida, Fabrício C. L.; Brennan, Michael J.; Joseph, Phillip F.; Gao, Yan; Paschoalini, Amarildo T.

    2018-04-01

    In the use of acoustic correlation methods for water leak detection, sensors are placed at pipe access points either side of a suspected leak, and the peak in the cross-correlation function of the measured signals gives the time difference (delay) between the arrival times of the leak noise at the sensors. Combining this information with the speed at which the leak noise propagates along the pipe, gives an estimate for the location of the leak with respect to one of the measurement positions. It is possible for the structural dynamics of the pipe system to corrupt the time delay estimate, which results in the leak being incorrectly located. In this paper, data from test-rigs in the United Kingdom and Canada are used to demonstrate this phenomenon, and analytical models of resonators are coupled with a pipe model to replicate the experimental results. The model is then used to investigate which of the two commonly used correlation algorithms, the Basic Cross-Correlation (BCC) function or the Phase Transform (PHAT), is more robust to the undesirable structural dynamics of the pipe system. It is found that time delay estimation is highly sensitive to the frequency bandwidth over which the analysis is conducted. Moreover, it is found that the PHAT is particularly sensitive to the presence of resonances and can give an incorrect time delay estimate, whereas the BCC function is found to be much more robust, giving a consistently accurate time delay estimate for a range of dynamic conditions.

  20. Development and deployment of miniature MI type sodium leak detector for FBTR

    International Nuclear Information System (INIS)

    Babu, B.; Sylvia, J.I.; Sureshkumar, K.V.; Rajan, K.K.

    2013-01-01

    Highlights: ► Development and commissioning of SG leak detection system for FBTR. ► Performance satisfactory except for a sodium leak due to failure of nicked diffuser. ► Available sodium leak detection systems explored. ► Mutual inductance leak detector designed and developed for sodium leak detection. ► System was tested and deployed in FBTR with satisfactory performance. -- Abstract: The energy produced in Fast Breeder Test Reactor (FBTR) is transferred to feed water for generating superheated steam in once-through shell and tube type counter current steam generator (SG). Sodium and water/steam flow in shell and tube side respectively are separated by thin-walls of ferritic steel tubes. Material defects in these tubes can lead to leakage of water/steam into sodium, resulting in sodium water reactions leading to undesirable consequences. Detection of a leak at its inception, therefore, is important for the safe and reliable operation of the reactor. Monitoring hydrogen in sodium, produced during reaction of sodium with the leaked water or steam is a convenient way to accomplish this. Nickel diffuser based instrumentation has been developed for real time detection of steam generator leak of FBTR at Kalpakkam. Though the performance of the system has been satisfactory, the failure of Nickel diffuser cannot be ruled out. This paper deals with the development and deployment of a miniature Mutual Inductance (MI) type leak detector for detection of sodium leak resulting from failure/rupture of the Nickel diffuser tubes in the SG leak detection system in FBTR

  1. [Endonasal endoscopic surgery in the treatment of spontaneous or post-traumatic cerebrospinal fluid (csf) leaks].

    Science.gov (United States)

    Nallet, E; Decq, P; Bezzo, A; Le Lievre, G; Peynegre, R; Coste, A

    1998-10-01

    The incidence and the risk of meningitidis justify treatment in all cases of cerebrospinal fluid rhinorrhea with spontaneous etiology or after traumatic injury. Endonasal surgery with endoscopic instruments provides many advantages compared with transcranial or transfacial approach used by neurosurgeons. We report our experience and our surgical technique in the treatment of CSF leaks in 5 patients. Intrathecal injection of fluoresceine was very useful in all cases for detecting the CSF leak. Total or selected ethmoidectomy depended on the localization of the leakage. Wide sphenoidotomy enables detection and repair of CSF leaks from the sphenoid cavity. A free graft of inferior turbinal mucosal was used to repair the breache. This rapid low morbidity surgery offered secure closure of rhinorrhea in 4 cases after one procedure and in 1 case after two procedures with an average follow up of 22 months. Cerebrospinal fluid rhinorrhea can be managed in first line therapy with endoscopic intranasal surgical techniques when they are localized in the anterior ethmoid or in the sphenoid cavity.

  2. Techniques for Primary-to-Secondary Leak Monitoring in PWR Plants

    International Nuclear Information System (INIS)

    Sohn, Wook; Chi, Jun Hwa; Kang, Duck Won; Tae, Jeong Woo

    2006-01-01

    Historically, corrosion and mechanical damage have made steam generator tubes in PWR plants see various types of degradation from both the primary and secondary sides of the tubes. Since the tube degradation can lead to through-wall failure, the plant personnel should make efforts to prevent the failure. One of such preventive efforts is to monitor primary-to-secondary leakage (PSL) that usually precedes the tube rupture. Thus the objective of PSL monitoring is to make operators to determine when to shutdown the plant in order to minimize the likelihood of propagation of leaks to tube rupture under normal and faulted conditions This paper addresses briefly the status of techniques for PSL monitoring used in PWR plants

  3. Experimental investigation of leak detection using mobile distributed monitoring system

    Science.gov (United States)

    Chen, Jiang; Zheng, Junli; Xiong, Feng; Ge, Qi; Yan, Qixiang; Cheng, Fei

    2018-01-01

    The leak detection of rockfill dams is currently hindered by spatial and temporal randomness and wide monitoring range. The spatial resolution of fiber Bragg grating (FBG) temperature sensing technology is related to the distance between measuring points. As a result, the number of measuring points should be increased to ensure that the precise location of the leak is detected. However, this leads to a higher monitoring cost. Consequently, it is difficult to promote and apply this technology to effectively monitor rockfill dam leakage. In this paper, a practical mobile distributed monitoring system with dual-tubes is used by combining the FBG sensing system and hydrothermal cycling system. This dual-tube structure is composed of an outer polyethylene of raised temperature resistance heating pipe, an inner polytetrafluoroethylene tube, and a FBG sensor string, among which, the FBG sensor string can be dragged freely in the internal tube to change the position of the measuring points and improve the spatial resolution. In order to test the effectiveness of the system, the large-scale model test of concentrated leakage in 13 working conditions is carried out by identifying the location, quantity, and leakage rate of leakage passage. Based on Newton’s law of cooling, the leakage state is identified using the seepage identification index ζ v that was confirmed according to the cooling curve. Results suggested that the monitoring system shows high sensitivity and can improve the spatial resolution with limited measuring points, and thus better locate the leakage area. In addition, the seepage identification index ζ v correlated well with the leakage rate qualitatively.

  4. Leak detection system with distributed microprocessor in the primary containment vessel

    International Nuclear Information System (INIS)

    Inahara, K.; Yoshioka, K.; Tomizawa, T.

    1980-01-01

    Responding to the demand for greater improvements of the safety monitoring system, less public radiation exposure, and increase of plant availability, measuring and control systems in nuclear power plants have undergone many improvements. Leak detection systems are also required to give earlier warning, additional accuracy, and continuous monitoring function. This paper describes the drywell sump leakage detection system utilizing a distributed microprocessor, which is a successful application owing to its versatile function and ease of installation. The microprocessor performs various functions such as a rate of level change computation, conversion to leakage flow rate, initiation of alarm, and sump pump control. This system has already been applied to three operating BWR plants that demonstrate its efficiency. (auth)

  5. Assessment of Current Inservice Inspection and Leak Monitoring Practices for Detecting Materials Degradation in Light Water Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Michael T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Simonen, Fredric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Muscara, Joseph [US Nuclear Regulatory Commission (NRC), Rockville, MD (United States); Doctor, Steven R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kupperman, David S. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-09-01

    An assessment was performed to determine the effectiveness of existing inservice inspection (ISI) and leak monitoring techniques, and recommend improvements, as necessary, to the programs as currently performed for light water reactor (LWR) components. Information from nuclear power plant (NPP) aging studies and from the U. S. Nuclear Regulatory Commission’s Generic Aging Lessons Learned (GALL) report (NUREG-1801) was used to identify components that have already experienced, or are expected to experience, degradation. This report provides a discussion of the key aspects and parameters that constitute an effective ISI program and a discussion of the basis and background against which the effectiveness of the ISI and leak monitoring programs for timely detection of degradation was evaluated. Tables based on the GALL components were used to systematically guide the process, and table columns were included that contained the ISI requirements and effectiveness assessment. The information in the tables was analyzed using histograms to reduce the data and help identify any trends. The analysis shows that the overall effectiveness of the ISI programs is very similar for both boiling water reactors (BWRs) and pressurized water reactors (PWRs). The evaluations conducted as part of this research showed that many ISI programs are not effective at detecting degradation before its extent reached 75% of the component wall thickness. This work should be considered as an assessment of NDE practices at this time; however, industry and regulatory activities are currently underway that will impact future effectiveness assessments. A number of actions have been identified to improve the current ISI programs so that degradation can be more reliably detected.

  6. Leak-before-break behaviour of nuclear piping systems

    International Nuclear Information System (INIS)

    Bartholome, G.; Wellein, R.

    1992-01-01

    The general concept for break preclusion of nuclear piping systems in the FRG consists of two main prerequisites: Basic safety; independent redundancies. The leak-before-break behaviour is open of these redundancies and will be verified by fracture mechanics. The following items have to be evaluated: The growth of detected and postulated defects must be negligible in one life time of the plant; the growth behaviour beyond design (i.e. multiple load collectives are taken into account) leads to a stable leak; This leakage of the piping must be detected by an adequate leak detection system long before the critical defect size is reached. The fracture mechanics calculations concerning growth and instability of the relevant defects and corresponding leakage areas are described in more detail. The leak-before-break behaviour is shown for two examples of nuclear piping systems in pressurized water reactors: main coolant line of SIEMENS-PWR 1300 MW (ferritic material, diameter 800 mm); surge line of Russian WWER 440 (austenitic material, diameter 250 mm). The main results are given taking into account the relevant leak detection possibilities. (author). 9 refs, 9 figs

  7. Wall conditioning and leak localization in the advanced toroidal facility

    International Nuclear Information System (INIS)

    Langley, R.A.; Glowienka, J.C.; Mioduszewski, P.K.; Murakami, M.; Rayburn, T.F.; Simpkins, J.E.; Schwenterly, S.W.; Yarber, J.L.

    1989-01-01

    The Advanced Toroidal Facility (ATF) vacuum vessel and its internal components have been conditioned for plasma operation by baking, discharge cleaning with hydrogen and helium, and gettering with chromium and titanium. The plasma-facing surface of ATF consists mainly of stainless steel with some graphite; the outgassing area is dominated by the graphite because of its open porosity. Since this situation is somewhat different from that in other fusion plasma experiments, in which a single material dominates both the outgassing area and the plasma-facing area, different cleaning and conditioning techniques are required. The situation was aggravated by air leaks in the vacuum vessel, presumably resulting from baking and from vibration during plasma operation. The results of the various cleaning and conditioning techniques used are presented and compared on the basis of residual gas analysis and plasma performance. A technique for detecting leaks from the inside of the vacuum vessel is described; this technique was developed because access to the outside of the vessel is severely restricted by external components. 10 refs., 6 figs., 2 tabs

  8. Wall conditioning and leak localization in the Advanced Toroidal Facility

    International Nuclear Information System (INIS)

    Langley, R.A.; Glowienka, J.C.; Mioduszewski, P.K.; Murakami, M.; Rayburn, T.F.; Simpkins, J.E.; Schwenterly, S.W.; Yarber, J.L.

    1990-01-01

    The Advanced Toroidal Facility (ATF) vacuum vessel and its internal components have been conditioned for plasma operation by baking, discharge cleaning with hydrogen and helium, and gettering with chromium and titanium. The plasma-facing surface of ATF consists mainly of stainless steel with some graphite; the outgassing area is dominated by the graphite because of its open porosity. Since this situation is somewhat different from that in other fusion plasma experiments, in which a single material dominates both the outgassing area and the plasma-facing area, different cleaning and conditioning techniques are required. The situation was aggravated by air leaks in the vacuum vessel, presumably resulting from baking and from vibration during plasma operation. The results of the various cleaning and conditioning techniques used are presented and compared on the basis of residual gas analysis and plasma performance. A technique for detecting leaks from the inside of the vacuum vessel is described. This technique was developed because access to the outside of the vessel is severely restricted by external components

  9. A conceptual methodology to design a decision support system to leak detection programs in water networks

    International Nuclear Information System (INIS)

    Di Federico, V.; Bottarelli, M.; Di Federico, I.

    2005-01-01

    The paper outlines a conceptual methodology to develop a decision support system to assist technicians managing water networks in selecting the appropriate leak detection method(s). First, the necessary knowledge about the network is recapitulated: location and characteristics of its physical components, but also water demand, breaks in pipes, and water quality data. Second, the water balance in a typical Italian Agency is discussed, suggesting method and procedures to evacuate and/or estimate each term in the mass balance equation. Then the available methods for leak detection are described in detail, from those useful in the pre-localization phase to those commonly adopted to pinpoint pipe failures and allow a rapid repair. Criteria to estimate costs associated with each of these methods are provided. Finally, the proposed structure of the DSS is described [it

  10. Development of cost effective fenceline monitoring approaches to support advanced leak detection and repair strategies

    Science.gov (United States)

    Cost-effective fence line and process monitoring systems to support advanced leak detection and repair (LDAR) strategies can enhance protection of public health, facilitate worker safety, and help companies realize cost savings by reducing lost product. The U.S. EPA Office of Re...

  11. An algorithm for leak locating using coupled vibration of pipe-water

    International Nuclear Information System (INIS)

    Lee, Young Sup; Yoon, Dong Jin

    2004-01-01

    Leak noise is a good source to identify the exact location of a leak point of underground water pipelines. Water leak generates broadband sound from a leak location and this sound propagation due to leak in water pipelines is not a non-dispersive wave any more because of the surrounding pipes and soil. However, the necessity of long-range detection of this leak location makes to identify low-frequency acoustic waves rather than high frequency ones. Acoustic wave propagation coupled with surrounding boundaries including cast iron pipes is theoretically analyzed and the wave velocity was confirmed with experiment. The leak locations were identified both by the Acoustic Emission (AE) method and the cross-correlation method. In a short-range distance, both the AE method and cross-correlation method are effective to detect leak position. However, the detection for a long-range distance required a lower frequency range accelerometers only because higher frequency waves were attenuated very quickly with the increase of propagation paths. Two algorithms for the cross-correlation function were suggested, and a long-range detection has been achieved at real underground water pipelines longer than 300m

  12. Leaking Fuel Impacts and Practices

    International Nuclear Information System (INIS)

    Hozer, Zoltan; Szabo, Peter; Somfai, Barbara; Cherubini, Marco; Aldworth, Robin; Waeckel, Nicolas; Delorme, Tim; Dickson, Raymond; Fujii, Hajime; Rey Gayo, Jose Maria; Grant, Wade; Gorzel, Andreas; Hellwig, Christian; Kamimura, Katsuichiro; Sugiyama, Tomoyuki; Klouzal, Jan; Miklos, Marek; Nagase, Fumihisa; Nilsson, Marcus; Petit, Marc; Richards, Stuart; Lundqvist Saleh, Tobias; Stepniewski, Marek; Sim, Ki Seob; ); Rehacek, Radomir; Kissane, Martin; )

    2014-01-01

    intact assemblies in most of the countries. On the basis of the review the working group proposed benchmark calculations to compare the simulation of the role of leaking rods in accident conditions and the organisation of meetings dealing with the techniques applied to handle leaking fuel assemblies and rods. (authors)

  13. Hyperspectral detection of a subsurface CO2 leak in the presence of water stressed vegetation.

    Directory of Open Access Journals (Sweden)

    Gabriel J Bellante

    Full Text Available Remote sensing of vegetation stress has been posed as a possible large area monitoring tool for surface CO2 leakage from geologic carbon sequestration (GCS sites since vegetation is adversely affected by elevated CO2 levels in soil. However, the extent to which remote sensing could be used for CO2 leak detection depends on the spectral separability of the plant stress signal caused by various factors, including elevated soil CO2 and water stress. This distinction is crucial to determining the seasonality and appropriateness of remote GCS site monitoring. A greenhouse experiment tested the degree to which plants stressed by elevated soil CO2 could be distinguished from plants that were water stressed. A randomized block design assigned Alfalfa plants (Medicago sativa to one of four possible treatment groups: 1 a CO2 injection group; 2 a water stress group; 3 an interaction group that was subjected to both water stress and CO2 injection; or 4 a group that received adequate water and no CO2 injection. Single date classification trees were developed to identify individual spectral bands that were significant in distinguishing between CO2 and water stress agents, in addition to a random forest classifier that was used to further understand and validate predictive accuracies. Overall peak classification accuracy was 90% (Kappa of 0.87 for the classification tree analysis and 83% (Kappa of 0.77 for the random forest classifier, demonstrating that vegetation stressed from an underground CO2 leak could be accurately discerned from healthy vegetation and areas of co-occurring water stressed vegetation at certain times. Plants appear to hit a stress threshold, however, that would render detection of a CO2 leak unlikely during severe drought conditions. Our findings suggest that early detection of a CO2 leak with an aerial or ground-based hyperspectral imaging system is possible and could be an important GCS monitoring tool.

  14. Hyperspectral detection of a subsurface CO2 leak in the presence of water stressed vegetation.

    Science.gov (United States)

    Bellante, Gabriel J; Powell, Scott L; Lawrence, Rick L; Repasky, Kevin S; Dougher, Tracy

    2014-01-01

    Remote sensing of vegetation stress has been posed as a possible large area monitoring tool for surface CO2 leakage from geologic carbon sequestration (GCS) sites since vegetation is adversely affected by elevated CO2 levels in soil. However, the extent to which remote sensing could be used for CO2 leak detection depends on the spectral separability of the plant stress signal caused by various factors, including elevated soil CO2 and water stress. This distinction is crucial to determining the seasonality and appropriateness of remote GCS site monitoring. A greenhouse experiment tested the degree to which plants stressed by elevated soil CO2 could be distinguished from plants that were water stressed. A randomized block design assigned Alfalfa plants (Medicago sativa) to one of four possible treatment groups: 1) a CO2 injection group; 2) a water stress group; 3) an interaction group that was subjected to both water stress and CO2 injection; or 4) a group that received adequate water and no CO2 injection. Single date classification trees were developed to identify individual spectral bands that were significant in distinguishing between CO2 and water stress agents, in addition to a random forest classifier that was used to further understand and validate predictive accuracies. Overall peak classification accuracy was 90% (Kappa of 0.87) for the classification tree analysis and 83% (Kappa of 0.77) for the random forest classifier, demonstrating that vegetation stressed from an underground CO2 leak could be accurately discerned from healthy vegetation and areas of co-occurring water stressed vegetation at certain times. Plants appear to hit a stress threshold, however, that would render detection of a CO2 leak unlikely during severe drought conditions. Our findings suggest that early detection of a CO2 leak with an aerial or ground-based hyperspectral imaging system is possible and could be an important GCS monitoring tool.

  15. FUZZY INFERENCE BASED LEAK ESTIMATION IN WATER PIPELINES SYSTEM

    Directory of Open Access Journals (Sweden)

    N. Lavanya

    2015-01-01

    Full Text Available Pipeline networks are the most widely used mode for transporting fluids and gases around the world. Leakage in this pipeline causes harmful effects when the flowing fluid/gas is hazardous. Hence the detection of leak becomes essential to avoid/minimize such undesirable effects. This paper presents the leak detection by spectral analysis methods in a laboratory pipeline system. Transient in the pressure signal in the pipeline is created by opening and closing the exit valve. These pressure variations are captured and power spectrum is obtained by using Fast Fourier Transform (FFT method and Filter Diagonalization Method (FDM. The leaks at various positions are simulated and located using these methods and the results are compared. In order to determine the quantity of leak a 2 × 1 fuzzy inference system is created using the upstream and downstream pressure as input and the leak size as the output. Thus a complete leak detection, localization and quantification are done by using only the pressure variations in the pipeline.

  16. Anatomy of a defective barrier: sequential glove leak detection in a surgical and dental environment.

    Science.gov (United States)

    Albin, M S; Bunegin, L; Duke, E S; Ritter, R R; Page, C P

    1992-02-01

    a) To determine the frequency of perforations in latex surgical gloves before, during, and after surgical and dental procedures; b) to evaluate the topographical distribution of perforations in latex surgical gloves after surgical and dental procedures; and c) to validate methods of testing for latex surgical glove patency. Multitrial tests under in vitro conditions and a prospective sequential patient study using consecutive testing. An outpatient dental clinic at a university dental school, the operating suite in a medical school affiliated with the Veteran's Hospital, and a biomechanics laboratory. Surgeons, scrub nurses, and dental technicians participating in 50 surgical and 50 dental procedures. We collected 679 latex surgical gloves after surgical procedures and tested them for patency by using a water pressure test. We also employed an electronic glove leak detector before donning, after sequential time intervals, and upon termination of 47 surgical (sequential surgical), 50 dental (sequential dental), and in three orthopedic cases where double gloving was used. The electronic glove leak detector was validated by using electronic point-by-point surface probing, fluorescein dye diffusion, as well as detecting glove punctures made with a 27-gauge needle. The random study indicated a leak rate of 33.0% (224 out of 679) in latex surgical gloves; the sequential surgical study demonstrated patency in 203 out of 347 gloves (58.5%); the sequential dental study showed 34 leaks in the 106 gloves used (32.1%); and with double gloving, the leak rate decreased to 25.0% (13 of 52 gloves tested). While the allowable FDA defect rate for unused latex surgical gloves is 1.5%, we noted defect rates in unused gloves of 5.5% in the sequential surgical, 1.9% in the sequential dental, and 4.0% in our electronic glove leak detector validating study. In the sequential surgical study, 52% of the leaks had occurred by 75 mins, and in the sequential dental study, 75% of the leaks

  17. Application of Morphological Segmentation to Leaking Defect Detection in Sewer Pipelines

    Directory of Open Access Journals (Sweden)

    Tung-Ching Su

    2014-05-01

    Full Text Available As one of major underground pipelines, sewerage is an important infrastructure in any modern city. The most common problem occurring in sewerage is leaking, whose position and failure level is typically identified through closed circuit television (CCTV inspection in order to facilitate rehabilitation process. This paper proposes a novel method of computer vision, morphological segmentation based on edge detection (MSED, to assist inspectors in detecting pipeline defects in CCTV inspection images. In addition to MSED, other mathematical morphology-based image segmentation methods, including opening top-hat operation (OTHO and closing bottom-hat operation (CBHO, were also applied to the defect detection in vitrified clay sewer pipelines. The CCTV inspection images of the sewer system in the 9th district, Taichung City, Taiwan were selected as the experimental materials. The segmentation results demonstrate that MSED and OTHO are useful for the detection of cracks and open joints, respectively, which are the typical leakage defects found in sewer pipelines.

  18. Experiments in LEENA facility with modified wire type leak detector layout in large sodium pipelines

    International Nuclear Information System (INIS)

    Vijayakumar, G.; Chandramouli, S.; Nashine, B.K.; Selvaraj, P.; Rajan, K.K.

    2017-01-01

    Highlights: • FBR large horizontal secondary pipeline were simulated and five sodium leak experiments were conducted by providing modified wire type leak detector layout at 550 °C. • Early detection of sodium leak is needed for minimizing the sodium leaked out and consequent damages. • PFBR leak detector layout on large horizontal pipelines can detect a leak rate of 200 g/h within 6 h. • By reducing the distance between leak point and detector to half, detection time was reduced to 1/6th and found that a leak rate of 200 g/h can be detected in one hour. • A relationship between leak rate and detection time was established based on experimental results. - Abstract: Sodium cooled Fast Breeder Reactors (SFRs) are envisaged in the second phase of Indian nuclear power programme. Liquid sodium is used as the coolant in the SFRs due to its favourable nuclear properties and excellent heat transfer properties. Leaks in sodium systems have the potential of being exceptionally hazardous due to the reaction of liquid sodium with oxygen and water vapour in the air. When a sodium leak occurs, the sodium leak rate, the total quantity of sodium leaked and leak detector layout governs the detection time. Other factors to be considered are insulation material packing condition, distance between the leak point and detector, heater layout, pipe geometry, temperature etc. Potential regions of leakage in Fast Breeder Reactor (FBR) sodium circuits are near welds, high stress areas and regions subjected to thermal striping. Early detection of leak is needed for minimizing the quantity of sodium leaked to outside and consequent damages. Three wire type leak detectors (WLDs positioned at 90°, 180° and 270°) working on conductivity principle are used for detecting sodium leak in the large horizontal secondary sodium pipelines of Prototype Fast Breeder Reactor (PFBR). It was found from the upper boundary curve based on LEENA (LEak Experiments in NAtrium) facility experimental

  19. Ultrasonic Detectors Safely Identify Dangerous, Costly Leaks

    Science.gov (United States)

    2013-01-01

    In 1990, NASA grounded its space shuttle fleet. The reason: leaks detected in the hydrogen fuel systems of the Space Shuttles Atlantis and Columbia. Unless the sources of the leaks could be identified and fixed, the shuttles would not be safe to fly. To help locate the existing leaks and check for others, Kennedy Space Center engineers used portable ultrasonic detectors to scan the fuel systems. As a gas or liquid escapes from a leak, the resulting turbulence creates ultrasonic noise, explains Gary Mohr, president of Elmsford, New York-based UE Systems Inc., a long-time leader in ultrasonic detector technologies. "In lay terms, the leak is like a dog whistle, and the detector is like the dog ear." Because the ultrasound emissions from a leak are highly localized, they can be used not only to identify the presence of a leak but also to help pinpoint a leak s location. The NASA engineers employed UE s detectors to examine the shuttle fuel tanks and solid rocket boosters, but encountered difficulty with the devices limited range-certain areas of the shuttle proved difficult or unsafe to scan up close. To remedy the problem, the engineers created a long-range attachment for the detectors, similar to "a zoom lens on a camera," Mohr says. "If you are on the ground, and the leak is 50 feet away, the detector would now give you the same impression as if you were only 25 feet away." The enhancement also had the effect of reducing background noise, allowing for a clearer, more precise detection of a leak s location.

  20. Detecting gas leaks by ultrasonic emission

    DEFF Research Database (Denmark)

    Rasmussen, Karsten Bo; Henriksen, Eigil

    1997-01-01

    The emission of noise in the frequency range 10 kHz to 25.6 kHz from an experimental gas leak in a flanged joint has been experimentally investigated. The overall conclusion is that the emitted noise is almost frequency independent in level within the considered frequency range.A small PC program...

  1. Hepatobiliary scintigraphy in patients with bile leaks

    International Nuclear Information System (INIS)

    Carichner, S.L.; Nagle, C.E.

    1987-01-01

    Hepatobiliary scintigraphy has been recognized as a useful tool in detecting the presence and sites of bile leaks. The clinical settings in which bile leaks are likely to occur, as well as some of the scintigraphic patterns seen in patients with bile leaks, are reviewed here. Tips for technologists are offered on interventions that might enhanced the quality of information available to the nuclear physician

  2. 77 FR 6857 - Pipeline Safety: Notice of Public Meetings on Improving Pipeline Leak Detection System...

    Science.gov (United States)

    2012-02-09

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket ID... installed to lessen the volume of natural gas and hazardous liquid released during catastrophic pipeline... p.m. Panel 3: Considerations for Natural Gas Pipeline Leak Detection Systems 3:30 p.m. Break 3:45 p...

  3. Conceptual design report for the project to install leak detection in FAST-FT-534/548/549

    Energy Technology Data Exchange (ETDEWEB)

    Galloway, K.J.

    1992-07-01

    This report provides conceptual designs and design recommendations for installing secondary containment and leak detection systems for three sumps at the Fluorinel and Storage Facility (FAST), CPP-666. The FAST facility is located at the Idaho Chemical Processing Plant (ICPP) at the Idaho National Engineering Laboratory (INEL). The three sumps receive various materials from the FAST water treatment process. This project involves sump upgrades to meet appropriate environmental requirements. The steps include: providing sump modifications or designs for the installation of leak chases and/or leakage accumulation, coating the sump concrete with a chemical resistant sealant (except for sump VES-FT-534 which is already lined with stainless steel) to act as secondary containment, lining the sumps with a primary containment system, and providing a means to detect and remove primary containment leakage that may occur.

  4. Conceptual design report for the project to install leak detection in FAST-FT-534/548/549

    International Nuclear Information System (INIS)

    Galloway, K.J.

    1992-07-01

    This report provides conceptual designs and design recommendations for installing secondary containment and leak detection systems for three sumps at the Fluorinel and Storage Facility (FAST), CPP-666. The FAST facility is located at the Idaho Chemical Processing Plant (ICPP) at the Idaho National Engineering Laboratory (INEL). The three sumps receive various materials from the FAST water treatment process. This project involves sump upgrades to meet appropriate environmental requirements. The steps include: providing sump modifications or designs for the installation of leak chases and/or leakage accumulation, coating the sump concrete with a chemical resistant sealant (except for sump VES-FT-534 which is already lined with stainless steel) to act as secondary containment, lining the sumps with a primary containment system, and providing a means to detect and remove primary containment leakage that may occur

  5. Continuous time-resolved regional methane leak detection with on-line background estimation using a novel combination of dual frequency comb laser spectroscopy and atmospheric inversions

    Science.gov (United States)

    Alden, C. B.; Coburn, S.; Wright, R.; Baumann, E.; Cossel, K.; Sweeney, C.; Ghosh, S.; Newbury, N.; Prasad, K.; Coddington, I.; Rieker, G. B.

    2017-12-01

    Advances in natural gas extraction technology have led to increased US production and transport activity, and as a consequence, an increased need for monitoring of methane leaks. Current leak detection methods provide time snapshots, and not continuous, time-varying estimates of emissions. Most approaches also require specific atmospheric conditions, operators, or the use of a tracer gas, requiring site access. Given known intermittency in fugitive methane emissions, continuous monitoring is a critical need for emissions mitigation. We present a novel leak detection method that employs dual frequency comb spectrometry to offer continuous, autonomous, leak detection and quantification over square-km scale areas. The spectrometer is situated in a field of natural gas pads, and a series of retroreflectors around the field direct light back to a detector. The laser light spans 1620-1680 nm with 0.002 nm line spacing, measuring thousands of individual absorption features from multiple species. The result is high-stability trace gas (here CH4, CO2, and H2O) measurements over long (1 km+) open paths through the atmosphere. Measurements are used in an atmospheric inversion to estimate the time variability of emissions at each location of interest. Importantly, the measurement framework and inversion solve explicitly for background concentrations, which vary rapidly in fields of active oil and gas production. We present the results of controlled-leak field tests in rural Colorado. We demonstrate the ability to locate and size a leak located 1 km away from the spectrometer and varying in strength from 1.5 to 7.7 g/min, resulting in mean atmospheric enhancements of 20 ppb. The inversion correctly identifies when the leak turned on and off over a 24-hour period, and determines the mean leak strength to within 10% of the true controlled rate. We further demonstrate the ability of the system to correctly locate and size the start and end of simultaneous 2.7 to 4.8 g/min leaks

  6. Small liquid sodium leaks

    International Nuclear Information System (INIS)

    Dufresne, J.; Rochedereux, Y.; Antonakas, D.; Casselman, C.; Malet, J.C.

    1986-05-01

    Usually, pessimistic considerations inassessing the safety of secondary sodium loops in LMFBR reactor lead to assume guillotine rupture releasing a large amount of sodium estimate the consequences of large sodium fires. In order to reduce these consequences, one has to detect the smallest leak as soon as possible and to evaluate the future of an initial small leak. Analysis of the relationship between crack size and sodium outflow rate; Analysis of a sodium pipe with a small open crack

  7. Leak Detectives Saving Money, Water in Virginia

    Science.gov (United States)

    “Circuit riders” from the Virginia Rural Water Association (VRWA) are traveling to small communities across the Commonwealth using special equipment financed by EPA to locate expensive and wasteful leaks in drinking water distribution systems.

  8. INNOVATIVE ACOUSTIC SENSOR TECHNOLOGIES FOR LEAK DETECTION IN CHALLENGING PIPE TYPES

    Science.gov (United States)

    2016-12-30

    the LeakFinderRT system is composed of leak sensors, a wireless signal transmission system, and a personal computer equipped with cross-correlation...Correlux: As shown in Figure 5.5, the Correlux system is composed of two leak sensors, a wireless signal transmission system, and a correlating device...investment ratio TB Test Bed UEM Utility and Energy Management vii ACKNOWLEDGEMENTS This work was supported by the U.S. Department of

  9. Primary circuit leak detection an application on PWR vessel head penetrations

    International Nuclear Information System (INIS)

    Loisy, F.; Germain, J.L.; Chauvel, L.

    1996-01-01

    In 1991, cracks were discovered and localized in the lower part of certain vessel head adapters in EDF PWR units. While awaiting the replacement of the vessel heads in question, EDF developed systems to enable continuous monitoring of vessel head penetration, by means of early detection of leaks. One of these systems in based on detection of water vapour in a confined space above the vessel head. The efficiency of the measurement chain is particularly dependent on dilution of the leakage in the confined space prior TO entry in the sampling circuit. The detection threshold for this method is on the order of 1.2 liters/hour for a dilution rate of 1500 rate of 1500 m 3 /h and a dew point of 22 deg C. This system has now been in operation on three 1300-MW PWR units for three years, and has proved to function satisfactorily. (authors)

  10. Application of fracture mechanics leak-before-break analyses for protection against pipe rupture in SEP plants

    International Nuclear Information System (INIS)

    Copeland, J.F.; Riccardella, P.C.

    1984-01-01

    In accordance with the latest NRC guidance the leak-before-break technique was evaluated for high-energy piping systems in a nuclear power plant. The elements of this evaluation include determination of: 1) largest crack size which will remain stable; 2) leak rate resulting from a crack with length twice the pipe wall thickness; 3) size of crack which will leak at a rate greater than 1 gpm, if 2) results in less than 1 gpm; and 4) analysis of part-through cracks for subcritical crack growth rates to establish in-service inspection (ISI) intervals. Conclusions reached are: 1) The fracture mechanics leak-before-break approach is shown as a viable option to prevent pipe rupture. 2) Austenitic stainless steel pipes possess significant toughness, and large cracks are required for rupture. 3) The net section plastic collapse analysis is more conservative than tearing modulus evaluations. 4) Leak rates are large enough to assure detection well before cracks reach a critical size. 5) In the case studied, subcritical crack growth is slow enough to require ISI intervals of about 10 years to detect part-through cracks

  11. Investigation for the sodium leak in Monju. Sodium leak and fire test-1

    International Nuclear Information System (INIS)

    Kawata, Koji; Ohno, Shuji; Miyahara, Shinya; Miyake, Osamu; Tanabe, Hiromi

    2000-08-01

    As a part of the work for investigating the sodium leak accident which occurred in the Monju reactor (hereinafter referred to as Monju) on December 8, 1995, three tests, (1) a sodium leak test, (2) a sodium leak and fire test-1, and (3) a sodium leak and fire test-II, were carried out at OEC/PEC. The main objectives of these tests were to confirm the leak and burning behavior of sodium from the damaged thermometer, and the effects of the sodium fire on the integrity of the surrounding structure. This report describes the results of the sodium fire test-I carried out as a preliminary test. The test was performed using the SOLFA-2 (Sodium Leak, Fire and Aerosol) facility on April 8, 1996. In this test, sodium heated to 480degC was leaked for approximately 1.5 hours from a leak simulating apparatus and caused to drop onto a ventilation duct and a grating with the same dimensions and layout as those in Monju. The main conclusions obtained from the test are shown below: 1) Observation from video cameras in the test revealed that in the early stages of the sodium leak, sodium dripped out of the flexible tube of the thermometer. This dripping and burning expanded in range as the sodium splashed on the duct. 2) No damage to the duct itself was detected. However, the aluminum louver frame of the ventilation duct's lower inlet was damaged. Its machine screws came off, leaving half of the grill (on the grating side) detached. 3) No large hole, like the one seen at Monju, was found when the grating was removed from the testing system for inspection, although the area centered on the point were the sodium dripped was damaged in a way indicating the first stages of grating failure. The 5mm square lattice was corroded through in some parts, and numerous blades (originally 3.2 mm thick) had become sharpened like the blade of a knife. 4) The burning pan underside thermocouple near the leak point measured 700degC in within approximately 10 minutes, and for the next hour remained

  12. Design of a Novel In-Pipe Reliable Leak Detector

    OpenAIRE

    Chatzigeorgiou, Dimitrios; Youcef-Toumi, Kamal; Ben-Mansour, Rached

    2013-01-01

    Leakage is the major factor for unaccounted losses in every pipe network around the world (oil, gas, or water). In most cases, the deleterious effects associated with the occurrence of leaks may present serious economical and health problems. Therefore, leaks must be quickly detected, located, and repaired. Unfortunately, most state-of-the-art leak detection systems have limited applicability, are neither reliable nor robust, while others depend on the user experience. In this paper, we prese...

  13. Damage phenomena at target surface by small leak

    International Nuclear Information System (INIS)

    Jeong, Kyung Chai; Jeong, J. Y.; Kim, B. H.; Kim, T. J.; Choi, J. H.

    2001-04-01

    Design of the steam generator should be considered the safety about the sodium-water reaction occurred by water leak in heat transfer tube. Water leak mainly occurred from welding defect at the process of tube connection, the vibration of heat transfer tube bundle in steam generating system, fretting, and pin hole in original tube manufacturing. The classification of water leak divided to two parts, roughly, in case of the water leak studies. One is small leak phenomena analysis, and the other is it of large leak which was mainly treated to the evaluation on pressure increasing from hydrogen gas formed by sodium-water reaction in sodium system. In small water leak, the leak propagation phenomena and the development of leak detecting system at initial stage of small water leak were studied, mainly. In this study, the corrosion phenomena on the target tube surface appeared by sodium-water reaction was analyzed through the small water leak experiments, and, also, the jet phenomena formed by N 2 gas injection through the leak nozzle under water medium was observed

  14. Leak detection in medium density polyethylene (MDPE) pipe using pressure transient method

    Science.gov (United States)

    Amin, M. M.; Ghazali, M. F.; PiRemli, M. A.; Hamat, A. M. A.; Adnan, N. F.

    2015-12-01

    Water is an essential part of commodity for a daily life usage for an average person, from personal uses such as residential or commercial consumers to industries utilization. This study emphasizes on detection of leaking in medium density polyethylene (MDPE) pipe using pressure transient method. This type of pipe is used to analyze the position of the leakage in the pipeline by using Ensemble Empirical Mode Decomposition Method (EEMD) with signal masking. Water hammer would induce an impulse throughout the pipeline that caused the system turns into a surge of water wave. Thus, solenoid valve is used to create a water hammer through the pipelines. The data from the pressure sensor is collected using DASYLab software. The data analysis of the pressure signal will be decomposed into a series of wave composition using EEMD signal masking method in matrix laboratory (MATLAB) software. The series of decomposition of signals is then carefully selected which reflected intrinsic mode function (IMF). These IMFs will be displayed by using a mathematical algorithm, known as Hilbert transform (HT) spectrum. The IMF signal was analysed to capture the differences. The analyzed data is compared with the actual measurement of the leakage in term of percentage error. The error recorded is below than 1% and it is proved that this method highly reliable and accurate for leak detection.

  15. Leak detection systems as a central component of pipeline safety concepts; Leckueberwachungssysteme als zentrale Bestandteile von Pipeline-Sicherheitskonzepten

    Energy Technology Data Exchange (ETDEWEB)

    Vogt, Daniel [KROHNE Oil and Gas B.V., Breda (Netherlands)

    2013-03-15

    The transport of materials in pipelines is continuously increasing worldwide. Pipelines are one of the most economic and safe transport systems in all directions. In order to ensure this, not only new pipelines but also existing pipelines have to be kept up to date technically. Leakages are a possible safety risk. Leaks are manifold and range from earth quakes, corrosion or material fatigue up to open-up by drilling by thieves. A specific leakage detection often is used in order to limit the risks. The minimization of the consequences of accidents, downtimes and product losses as well as regulatory procedures is the reason for the detection of leakages. Leaks in pipelines can be detected on different kinds - from a simple visual inspection during the inspection up to computer-assisted systems monitoring certain states also in underground and submarine pipeline.

  16. Leaked water detection device for control rod drive and BWR type reactor

    International Nuclear Information System (INIS)

    Takahashi, Ken.

    1995-01-01

    The device of the present invention can specify a control rod drive causing great amount of water leakage among a large number of control rod drives. Namely, water leaked from the control rod drives is introduced to each of leaked water pipelines. Further, it is introduced from the leaked water pipelines to flow glasses at which leaked water can visually be recognized individually, and then discharged through a drain pipeline. With such procedures, the amount of leaked water from the leaked water pipelines can visually be recognized at the flow glasses. As a result, the control rod drives which cause a great amount of leakage can be specified among large number of control rod drives. Accordingly, an accurate inspection schedule for a shaft-sealing portion of the control rod drives can be formed. The shaft-sealing portion degradated in the sealing property can reliably be inspected and repaired. Purge water can be ensured to improve reliability of the operation of equipments. (I.S.)

  17. Assessment of volume and leak measurements during CPAP using a neonatal lung model.

    Science.gov (United States)

    Fischer, H S; Roehr, C C; Proquitté, H; Wauer, R R; Schmalisch, G

    2008-01-01

    Although several commercial devices are available which allow tidal volume and air leak monitoring during continuous positive airway pressure (CPAP) in neonates, little is known about their measurement accuracy and about the influence of air leaks on volume measurement. The aim of this in vitro study was the validation of volume and leak measurement under CPAP using a commercial ventilatory device, taking into consideration the clinical conditions in neonatology. The measurement accuracy of the Leoni ventilator (Heinen & Löwenstein, Germany) was investigated both in a leak-free system and with leaks simulated using calibration syringes (2-10 ml, 20-100 ml) and a mechanical lung model. Open tubes of variable lengths were connected for leak simulation. Leak flow was measured with the flow-through technique. In a leak-free system the mean relative volume error +/-SD was 3.5 +/- 2.6% (2-10 ml) and 5.9 +/- 0.7% (20-60 ml), respectively. The influence of CPAP level, driving flow, respiratory rate and humidification of the breathing gas on the volume error was negligible. However, an increasing F(i)O(2) caused the measured tidal volume to increase by up to 25% (F(i)O(2) = 1.0). The relative error +/- SD of the leak measurements was -0.2 +/- 11.9%. For leaks > 19%, measured tidal volume was underestimated by more than 10%. In conclusion, the present in vitro study showed that the Leoni allowed accurate volume monitoring under CPAP conditions similar to neonates. Air leaks of up to 90% of patient flow were reliably detected. For an F(i)O(2) > 0.4 and for leaks > 19%, a numerical correction of the displayed volume should be performed.

  18. Modeling of leak detection system for high pressure transmission system of natural gas

    International Nuclear Information System (INIS)

    Qureshi, S.A.; Paracha, Z.J.; Ali, A.

    2005-01-01

    Gas Industry can be considered as one of the most important industries in the economy of any country. Safe Transportation of Gas is thus considered to be vital because interruption of Supply of Gas to consumers not only causes domestic problems but also loss of revenue to country. Now most of power generation Sector has switched over their system to Natural Gas. So, interruption of supply to this sector can cause a lot of problems. This paper has provided assessment of technology approach and formulated this approach for Leak Detection Model in High Pressure Transmission system for current and future operations, which will improve the efficiency of any transmission company to a great extent. This model can be extremely helpful in conditions of Rupture Emergencies or Leakage because of corrosive conditions of Pipeline to manage the situation of resources in pipeline network. Any exceptional readings or messages should alert the user to the fact that something is wrong with the system. Such a system helps a lot in the safe and efficient management of pipeline network. The data and information provided by the Leak Detection System applications will allow for efficient and safe pipeline operation maximizing profitability over the pipeline's service lifetime. (author)

  19. FIELD DEMONSTRATION OF INNOVATIVE LEAK DETECTION/LOCATION TECHNOLOGIES COUPLED WITH WALL-THICKNESS SCREENING FOR WATER MAINS

    Science.gov (United States)

    The U.S. Environmental Protection Agency sponsored a large-scale field demonstration of innovative leak detection/location and condition assessment technologies on a 76-year old, 2,500-ft long, cement-lined, 24-in. cast iron water main in Louisville, KY from July through Septembe...

  20. Improved estimation of leak location of pipelines using frequency band variation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Sup [Embedded System Engineering Department, Incheon National University, Incheon (Korea, Republic of); Yoon, Dong Jin [Safety Measurement Center, Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2014-02-15

    Leakage is an important factor to be considered for the management of underground water supply pipelines in a smart water grid system, especially if the pipelines are aged and buried under the pavement or various structures of a highly populated city. Because the exact detection of the location of such leaks in pipelines is essential for their efficient operation, a new methodology for leak location detection based on frequency band variation, windowing filters, and probability is proposed in this paper. Because the exact detection of the leak location depends on the precision of estimation of time delay between sensor signals due to leak noise, some window functions that offer weightings at significant frequencies are applied for calculating the improved cross-correlation function. Experimental results obtained by applying this methodology to an actual buried water supply pipeline, ∼ 253.9 m long and made of cast iron, revealed that the approach of frequency band variation with those windows and probability offers better performance for leak location detection.

  1. Improved estimation of leak location of pipelines using frequency band variation

    International Nuclear Information System (INIS)

    Lee, Young Sup; Yoon, Dong Jin

    2014-01-01

    Leakage is an important factor to be considered for the management of underground water supply pipelines in a smart water grid system, especially if the pipelines are aged and buried under the pavement or various structures of a highly populated city. Because the exact detection of the location of such leaks in pipelines is essential for their efficient operation, a new methodology for leak location detection based on frequency band variation, windowing filters, and probability is proposed in this paper. Because the exact detection of the leak location depends on the precision of estimation of time delay between sensor signals due to leak noise, some window functions that offer weightings at significant frequencies are applied for calculating the improved cross-correlation function. Experimental results obtained by applying this methodology to an actual buried water supply pipeline, ∼ 253.9 m long and made of cast iron, revealed that the approach of frequency band variation with those windows and probability offers better performance for leak location detection.

  2. An alarm instrument for monitoring leakage of oil storage tanks and the location of their leak position using radioisotope tracers

    International Nuclear Information System (INIS)

    Lu Qingqian; Sun Xiaolei; Hu Xusheng

    1990-01-01

    Usually it is difficult to find out gasoline leakage at the bottom of a storage tank from the very beginning. In order to solve this problem, a leak-monitoring technique and an instrument based on the detection of nuclear radiation have been successfully developed. The instrument possesses high sensitivity, short reaction time, excellent stability and rellability. When very small leaks at the bottom of a tank appear, the instrument will show a leak signal and give an alarm. In the meantime, however, the tank can be still used until the preparations for repairing are completed. Then its leak position can be accurately located by using radioisotope tracers

  3. Leak test fixture and method for using same

    Science.gov (United States)

    Hawk, Lawrence S.

    1976-01-01

    A method and apparatus are provided which are especially useful for leak testing seams such as an end closure or joint in an article. The test does not require an enclosed pressurized volume within the article or joint section to be leak checked. A flexible impervious membrane is disposed over an area of the seamed surfaces to be leak checked and sealed around the outer edges. A preselected vacuum is applied through an opening in the membrane to evacuate the area between the membrane and the surface being leak checked to essentially collapse the membrane to conform to the article surface or joined adjacent surfaces. A pressure differential is concentrated at the seam bounded by the membrane and only the seam experiences a pressure differential as air or helium molecules are drawn into the vacuum system through a leak in the seam. A helium detector may be placed in a vacuum exhaust line from the membrane to detect the helium. Alternatively, the vacuum system may be isolated at a preselected pressure and leaks may be detected by a subsequent pressure increase in the vacuum system.

  4. Analysis on signal properties due to concurrent leaks at two points in water supply pipelines

    International Nuclear Information System (INIS)

    Lee, Young Sup

    2015-01-01

    Intelligent leak detection is an essential component of a underground water supply pipeline network such as a smart water grid system. In this network, numerous leak detection sensors are needed to cover all of the pipelines in a specific area installed at specific regular distances. It is also necessary to determine the existence of any leaks and estimate its location within a short time after it occurs. In this study, the leak signal properties and feasibility of leak location detection were investigated when concurrent leaks occurred at two points in a pipeline. The straight distance between the two leak sensors in the 100A sized cast-iron pipeline was 315.6 m, and their signals were measured with one leak and two concurrent leaks. Each leak location was described after analyzing the frequency properties and cross-correlation of the measured signals.

  5. Analysis on signal properties due to concurrent leaks at two points in water supply pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Sup [Dept. of Embedded Systems Engineering, Incheon National University, Incheon (Korea, Republic of)

    2015-02-15

    Intelligent leak detection is an essential component of a underground water supply pipeline network such as a smart water grid system. In this network, numerous leak detection sensors are needed to cover all of the pipelines in a specific area installed at specific regular distances. It is also necessary to determine the existence of any leaks and estimate its location within a short time after it occurs. In this study, the leak signal properties and feasibility of leak location detection were investigated when concurrent leaks occurred at two points in a pipeline. The straight distance between the two leak sensors in the 100A sized cast-iron pipeline was 315.6 m, and their signals were measured with one leak and two concurrent leaks. Each leak location was described after analyzing the frequency properties and cross-correlation of the measured signals.

  6. Acoustic detection for small-leak sodium-water reaction

    International Nuclear Information System (INIS)

    Nei, Hiromichi; Ohshima, Iwao; Ujihara, Kozaburo; Hori, Masao

    1977-01-01

    Characteristics of acoustic signal produced by sodium-water reaction due to steam injection and by Ar gas injection into sodium were experimentally investigated. Acoustic signal was measured by using Kistler 808A and 815A5 accelerometers. Root mean square (RMS) measurements and frequency analysis of the signal were conducted. The RMS measurements could detect a small water leakage into sodium, as small as 0.07g/sec, in the present loop. The peaks in a frequency spectrum were caused by the natural vibration of a rod on which the acoustic transducer was mounted. The RMS was approximately proportional to the one-third power of the steam leak rate and increased to some extent with the ambient sodium temperature. RMS values, both for sodium-water reaction and Ar gas injection, were about the same order of magnitude, when the data were plotted against the volumetric flow rates of steam and Argas. (auth.)

  7. On the helium gas leak test

    International Nuclear Information System (INIS)

    Nishikawa, Akira; Ozaki, Susumu

    1975-01-01

    The helium gas leak test (Helium mass spectrometer testing) has a leak detection capacity of the highest level in practical leak tests and is going to be widely applied to high pressure vessels, atomic and vacuum equipments that require high tightness. To establish a standard test procedure several series of experiments were conducted and the results were investigated. The conclusions are summarized as follows: (1) The hood method is quantitatively the most reliable method. The leak rate obtained by tests using 100% helium concentration should be the basis of the other method of test. (2) The integrating method, bell jar method, and vacuum spray method can be considered quantitative when particular conditions are satisfied. (3) The sniffer method is not to be considered quantitive. (4) The leak rate of the hood, integrating, and bell jar methods is approximately proportional to the square of the helium partial pressure. (auth.)

  8. Leak testing requirements at a research facility

    International Nuclear Information System (INIS)

    Conner, J.B.

    1979-01-01

    Since September, 1952, Lawrence Livermore Laboratory has conducted pioneering research in applied science. A vital part of this activity has been the development of a variety of high vacuum and ultrahigh vacuum systems. Leaks occur in everything, including vacuum systems. The mass spectrometer leak detection equipment is described

  9. Small leak shutdown, location, and behavior in LMFBR steam generators

    International Nuclear Information System (INIS)

    Sandusky, D.W.

    1976-01-01

    The paper summarizes an experimental study of small leaks tested under LMFBR steam generator conditions. Defected tubes were exposed to flowing sodium and steam. The observed behavior of the defected tubes is reported along with test results of shutdown methods. Leak location methods were investigated. Methods were identified to open plugged defects for helium leak testing and detect plugged leaks by nondestructive testing

  10. A survey and description of candidate technologies to support single shell tank waste retrieval, leak detection, monitoring, and mitigation

    International Nuclear Information System (INIS)

    Lewis, R.E.; Teel, S.S.; Wegener, W.H.; Iwatate, D.F.

    1995-09-01

    This report was initially designed to provide a comprehensive review of potential leak detection technologies (LDTs). To this end, the report would contain several sections outlining the selection process. The purpose was twofold:(l) the reader would have a clear understanding of why specific technologies were recommended or not recommended, and (2) the reader could apply the same process in the future as new LDTs become available. Curtailment of project scope has prevented the development of the requisite judging criteria. The report has been modified accordingly. Section 2 of this report presents the baseline and guiding assumptions that were used to judge the LDTs. These assumptions include the environment where the technologies would be employed, the potential leak detection targets, and anticipated leak mechanisms. Section 3 presents a brief review of the methods used to arrive at the recommended LDTs. It also includes a description of the different technology families considered. Section 4 presents the recommended LDTs along with detailed descriptions of each that include sensitivities, operating parameters, and costs

  11. Leak or Fistula After Sleeve Gastrectomy: Treatment with Pigtail Drain by the Rendezvous Technique.

    Science.gov (United States)

    Soufron, Jacques

    2015-10-01

    After a sleeve gastrectomy, a leak or fistula is a serious complication. Laparoscopic drainage, drainage under US or CT scan control, or endoscopic insertion of a stent can be used, but a major re-operation is sometimes unavoidable. Endoscopic drainage with a pigtail catheter could give more success and fewer complications, but the insertion of the drain is not always possible nor does it always provide a perfect drainage. If a laparoscopic second look appears necessary, it is possible to insert a pigtail drain laparoscopically, but under endoscopic control, ensuring a correct positioning of the drain both in the peritoneal cavity and in the gastric tube. This simultaneous "rendezvous" technique could combine in this situation the advantages of purely surgical techniques and of purely endoscopic or image-guided techniques.

  12. Methods for leak detection for KWU pressurized and boiling water reactors

    International Nuclear Information System (INIS)

    Fischer, K.; Preusser, G.

    1991-01-01

    Leakage monitoring is an essential criterion to rule out the possibility of double ended pipe rupture in the primary coolant system. Subcritical cracks can be detected with a considerable margin before they extend to critical crack lengths resulting in spontaneous failure. In those KWU PWRs which went into operation recently, a Leakage Monitoring System was installed that is based on thermodynamic analysis. It utilizes the following measured parameters: dew point temperature, accumulated condensate inside aircoolers, air temperature, sump water level, gully monitoring. In KWU's BWRs although the measurement concept has to be slightly changed because of a different approaches design of buildings and components, the same instrumentation will be used. Besides this installed monitoring system, different like acoustic leak detection systems or the application of moisture sensitive instrumentation have been considered. Both systems have been successfully tested. (orig.)

  13. Assessment of volume and leak measurements during CPAP using a neonatal lung model

    International Nuclear Information System (INIS)

    Fischer, H S; Roehr, C C; Proquitté, H; Wauer, R R; Schmalisch, G

    2008-01-01

    Although several commercial devices are available which allow tidal volume and air leak monitoring during continuous positive airway pressure (CPAP) in neonates, little is known about their measurement accuracy and about the influence of air leaks on volume measurement. The aim of this in vitro study was the validation of volume and leak measurement under CPAP using a commercial ventilatory device, taking into consideration the clinical conditions in neonatology. The measurement accuracy of the Leoni ventilator (Heinen and Löwenstein, Germany) was investigated both in a leak-free system and with leaks simulated using calibration syringes (2–10 ml, 20–100 ml) and a mechanical lung model. Open tubes of variable lengths were connected for leak simulation. Leak flow was measured with the flow-through technique. In a leak-free system the mean relative volume error ±SD was 3.5 ± 2.6% (2–10 ml) and 5.9 ± 0.7% (20–60 ml), respectively. The influence of CPAP level, driving flow, respiratory rate and humidification of the breathing gas on the volume error was negligible. However, an increasing F i O 2 caused the measured tidal volume to increase by up to 25% (F i O 2 = 1.0). The relative error ±SD of the leak measurements was −0.2 ± 11.9%. For leaks >19%, measured tidal volume was underestimated by more than 10%. In conclusion, the present in vitro study showed that the Leoni allowed accurate volume monitoring under CPAP conditions similar to neonates. Air leaks of up to 90% of patient flow were reliably detected. For an F i O 2 >0.4 and for leaks >19%, a numerical correction of the displayed volume should be performed

  14. Applications of a morphological scene change detection (MSCD) for visual leak and failure identification in process and chemical engineering

    Science.gov (United States)

    Tickle, Andrew J.; Harvey, Paul K.; Smith, Jeremy S.

    2010-10-01

    Morphological Scene Change Detection (MSCD) is a process typically tasked at detecting relevant changes in a guarded environment for security applications. This can be implemented on a Field Programmable Gate Array (FPGA) by a combination of binary differences based around exclusive-OR (XOR) gates, mathematical morphology and a crucial threshold setting. The additional ability to set up the system in virtually any location due to the FPGA makes it ideal for insertion into an autonomous mobile robot for patrol duties. However, security is not the only potential of this robust algorithm. This paper details how such a system can be used for the detection of leaks in piping for use in the process and chemical industries and could be deployed as stated in the above manner. The test substance in this work was water, which was pumped either as a liquid or as low pressure steam through a simple pipe configuration with holes at set points to simulate the leaks. These holes were situated randomly at either the center of a pipe (in order to simulate an impact to it) or at a joint or corner (to simulate a failed weld). Imagery of the resultant leaks, which were visualised as drips or the accumulation of steam, which where analysed using MATLAB to determine their pixel volume in order to calibrate the trigger for the MSCD. The triggering mechanism is adaptive to make it possible in theory for the type of leak to be determined by the number of pixels in the threshold of the image and a numerical output signal to state which of the leak situations is being observed. The system was designed using the DSP Builder package from Altera so that its graphical nature is easily comprehensible to the non-embedded system designer. Furthermore, all the data from the DSP Builder simulation underwent verification against MATLAB comparisons using the image processing toolbox in order to validate the results.

  15. Development of a portable heavy-water leak sensor based on laser absorption spectroscopy

    International Nuclear Information System (INIS)

    Lee, Lim; Park, Hyunmin; Kim, Taek-Soo; Kim, Minho; Jeong, Do-Young

    2016-01-01

    Highlights: • We developed a compact and portable laser sensor for a detection of heavy water leakage. • The sensor is wearable and also easy to use to search for the leak point. • It is sensitive enough to find invisible very tiny leaks. - Abstract: A compact and portable leak sensor based on cavity enhanced absorption spectroscopy has been newly developed for a detection of heavy water leakage which may happen in the facilities using heavy water such as pressurized heavy water reactor (PHWR). The developed portable sensor is suitable as an individual instrument for the measuring leak rate and finding the leak location because it is sufficiently compact in size and weight and operated by using an internal battery. In the performance test, the minimum detectable leak rate was estimated as 0.05 g/day from the calibration curve. This new sensor is expected to be a reliable and promising device for the detection of heavy water leakage since it has advantages on real-time monitoring and early detection for nuclear safety.

  16. On-line low and high frequency acoustic leak detection and location for an automated steam generator protection system

    International Nuclear Information System (INIS)

    Gaubatz, D.C.; Gluekler, E.L.

    1990-01-01

    Two on-line acoustic leak detection systems were operated and installed on a 76 MW hockey stick steam generator in the Sodium Components Test Installation (SCTI) at the Energy Technology Engineering Center (ETEC) in Southern California. The low frequency system demonstrated the capability to detect and locate leaks, both intentional and unintentional. No false alarms were issued during the two year test program even with adjacent blasting activities, pneumatic drilling, shuttle rocket engine testing nearby, scrams of the SCTI facility, thermal/hydraulic transient testing, and pump/control valve operations. For the high frequency system the capability to detect water into sodium reactions was established utilizing frequencies as high as 300 kHz. The high frequency system appeared to be sensitive to noise generated by maintenance work and system valve operations. Subsequent development work which is incomplete as of this date showed much more promise for the high frequency system. (author). 13 figs

  17. Study of the characteristics of water into sodium leak acoustic noise in LMR steam generator

    International Nuclear Information System (INIS)

    Kim, Tae Joon; Jeong, Kyung Chai; Jeong, Ji Young; Hur, Seop; Nam, Ho Yun

    2005-01-01

    A successful time for detecting a water/steam leak into sodium in the LMR SG (steam generator) at an early phase of a leak origin depends on the fast response and sensitivity of a leak detection system. It is considered, that the acoustic system is intended for a fast detecting of a water/steam into sodium leak of an intermediate flow rate, 1∼10 g/s. This intention of an acoustic system is stipulated by a key impossibility of a fast detecting of an intermediate leak by the present nominal systems on measuring the hydrogen in the sodium and in the cover gas concentration generated at a leak. During the self-wastage of a water/steam into sodium leak in a particular instant, it is usual in 30∼40 minutes from the moment of a leak origin, there is a modification of a leak flow out regime from bubble regime to the steam jet outflow. This evolution occurs as a jump function of the self-wastage of a leak and is escorted by an increase of a leak noise power and qualitative change of a leak noise spectrum. Subject of this study is by means of two experiments, one is an acoustic leak noise analysis of the water into sodium leak results in no damage to the LMR SG tube bundle, and another is for prediction of the frequency band under a high outflow leak condition. We experimented with the Argon gas injection considered with the phenomena of secondary leaks in real

  18. Leak detection for city gas pipelines based on instantaneous energy distribution characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Zhigang, Chen [Deijing University of Civil Engineering and Architecture, Beijing, (China)

    2010-07-01

    Many natural gas pipelines are used in our cities. The development of efficient leakage detection systems is fundamental for safety issues avoidance. This paper investigated a new solution to the leak detection problem in city gas pipelines based on instantaneous energy distribution. In a theoretical approach, the Hilbert-Huang transform (HHT) was used to provide the instantaneous energy distribution feature of an unstable pressure signal. The signal noise was eliminated thanks to the instantaneous energy contribution. A leakage detection model with instantaneous energy distribution (IED) was then established. The correlation coefficients of instantaneous energy distribution were through correlation analysis. It was found that in different pipeline states, the instantaneous energy distribution characteristics are different. A strong correlation of IED signal characteristics was found of the two ends of a city gas pipeline in the same operation. The test results demonstrated the reliability and validity of the method.

  19. Preliminary Study of Feasibility of Acoustic Detection of Small Sodium-Water Reactions in Lmfbr Steam Generators.

    Energy Technology Data Exchange (ETDEWEB)

    Chamberlain, H. V.

    1970-06-01

    An evaluation of acoustic techniques for the detection of sound resulting from water leaks into liquid sodium was conducted. Acoustic spectra over the range of 100Hz to 80kHz were detected. A leak as small as 0.00008 lb/ sec was detected by the acoustic instrumentation. The indicated leak rate was the smallest that was injected into the liquid sodium, and is not to be interpreted as the smallest leak rate that might be detected by the acoustic method. Detection time was found to be essentially instantaneous.

  20. Margins in high temperature leak-before-break assessments

    Energy Technology Data Exchange (ETDEWEB)

    Budden, P.J.; Hooton, D.G.

    1997-04-01

    Developments in the defect assessment procedure R6 to include high-temperature mechanisms in Leak-before-Break arguments are described. In particular, the effect of creep on the time available to detect a leak and on the crack opening area, and hence leak rate, is discussed. The competing influence of these two effects is emphasized by an example. The application to Leak-before-Break of the time-dependent failure assessment diagram approach for high temperature defect assessment is then outlined. The approach is shown to be of use in assessing the erosion of margins by creep.

  1. Margins in high temperature leak-before-break assessments

    International Nuclear Information System (INIS)

    Budden, P.J.; Hooton, D.G.

    1997-01-01

    Developments in the defect assessment procedure R6 to include high-temperature mechanisms in Leak-before-Break arguments are described. In particular, the effect of creep on the time available to detect a leak and on the crack opening area, and hence leak rate, is discussed. The competing influence of these two effects is emphasized by an example. The application to Leak-before-Break of the time-dependent failure assessment diagram approach for high temperature defect assessment is then outlined. The approach is shown to be of use in assessing the erosion of margins by creep

  2. Fast reactor sodium systems operation experience and 'leak-before-break' criterion

    International Nuclear Information System (INIS)

    Ivanenko, V.N.; Zybin, V.A.

    1996-01-01

    In the paper sodium leakage detection systems used at fast reactors are described. Requirements on their main characteristics (sensitivity, response lime) are formulated. Results of tests are presented on studying the parameters of sodium leak detection systems including experiments on the measurement of size distribution of aerosol particles that have passed through sodium systems thermal insulation after leak initiation. Comparison of these data with dispersion of particles formed at free burning is carried out. Experience of real leaks that occurred at fast reactor sodium systems is analyzed. It has been shown that initiation and development of real leaks do not always follow the theoretical scheme. A substantial role of human factor for sodium systems reliability relative to sodium leaks is stressed. (author)

  3. Fuel rod leak detector

    International Nuclear Information System (INIS)

    Womack, R.E.

    1978-01-01

    A typical embodiment of the invention detects leaking fuel rods by means of a radiation detector that measures the concentration of xenon-133 ( 133 Xe) within each individual rod. A collimated detector that provides signals related to the energy of incident radiation is aligned with one of the ends of a fuel rod. A statistically significant sample of the gamma radiation (γ-rays) that characterize 133 Xe is accumulated through the detector. The data so accumulated indicates the presence of a concentration of 133 Xe appropriate to a sound fuel rod, or a significantly different concentration that reflects a leaking fuel rod

  4. Identification of sewage leaks by active remote-sensing methods

    Science.gov (United States)

    Goldshleger, Naftaly; Basson, Uri

    2016-04-01

    The increasing length of sewage pipelines, and concomitant risk of leaks due to urban and industrial growth and development is exposing the surrounding land to contamination risk and environmental harm. It is therefore important to locate such leaks in a timely manner, to minimize the damage. Advances in active remote sensing Ground Penetrating Radar (GPR) and Frequency Domain Electromagnetic (FDEM) technologies was used to identify leaking potentially responsible for pollution and to identify minor spills before they cause widespread damage. This study focused on the development of these electromagnetic methods to replace conventional acoustic methods for the identification of leaks along sewage pipes. Electromagnetic methods provide an additional advantage in that they allow mapping of the fluid-transport system in the subsurface. Leak-detection systems using GPR and FDEM are not limited to large amounts of water, but enable detecting leaks of tens of liters per hour, because they can locate increases in environmental moisture content of only a few percentage along the pipes. The importance and uniqueness of this research lies in the development of practical tools to provide a snapshot and monitoring of the spatial changes in soil moisture content up to depths of about 3-4 m, in open and paved areas, at relatively low cost, in real time or close to real time. Spatial measurements performed using GPR and FDEM systems allow monitoring many tens of thousands of measurement points per hectare, thus providing a picture of the spatial situation along pipelines and the surrounding. The main purpose of this study was to develop a method for detecting sewage leaks using the above-proposed geophysical methods, since their contaminants can severely affect public health. We focused on identifying, locating and characterizing such leaks in sewage pipes in residential and industrial areas.

  5. Leak testing at Westinghouse Hanford Company for the Fast Flux Test Facility (FFTF)

    International Nuclear Information System (INIS)

    Jackson, C.N.

    1981-01-01

    Described leak testing applications require an arsenal of test equipment, a diverse range of testing techniques and a cadre of technical talent. A wide range helium mass spectrometer leak detector, a volume change tester and a halogen detector are employed to cover the 1 x 10 -8 to 1 atm cc/sec leak rate range encountered. Leak testing techniques, equipment problems, costs, and recommendations are discussed for examination of reactor pressure boundary and other ancillary components of the FFTF

  6. Leak detection of steam or water into sodium in steam generators of liquid-metal fast breeder reactors

    International Nuclear Information System (INIS)

    Hans, R.; Dumm, K.

    1977-01-01

    The leakage of water or steam into sodium in LMFBR steam generators, including a study of how leaks are detected and located as well as the potential damage that could be caused by such leaks, is surveyed. The most interesting steam generator designs evolving in those countries that develop and construct LMFBRs are presented. The relevant protection measures are described. Fault conditions are defined and descriptions given of possible sequences of events leading to abnormal conditions in a steam generator. Taking into account theory, the potential of the hydrogen and oxygen detection systems is discussed. Different hydrogen and oxygen detection systems are fully described. In so far as interesting technical solutions are concerned, previously developed devices have also been taken into account. The way oxygen detection supplements hydrogen detection is described by listing the available oxygen measuring devices and the relevant theory. Only a few sonic and accelerometer measurements have been made on complete steam generator units so there is little system data available. Descriptions, however, have been included to give the state of the art achieved for the sensors and the achieved sensitivities or band widths. The potential of this monitoring method is made evident by adding the technical data of the sensors. Furthermore, the available systems for monitoring medium and large leakages are described. Finally, recommendations are made concerning steam generator development and the application of hydrogen and oxygen detection systems, as well as acoustic measuring methods for small-leakage detection

  7. Field Demonstration of Innovative Leak Detection/Location in Conjunction with Pipe Wall Thickness Testing for Water Mains

    Science.gov (United States)

    The U.S. Environmental Protection Agency (EPA) sponsored a large-scale field demonstration of innovative leak detection/location and condition assessment technologies on a 76-year old, 2,000-ft long, cement-lined, 24-in. cast iron water main in Louisville, KY from July through Se...

  8. Study of the isolability of leaks in a network depending on calibration of demands

    OpenAIRE

    Pérez Magrané, Ramon; Nejjari Akhi-Elarab, Fatiha; Puig Cayuela, Vicenç; Quevedo Casín, Joseba Jokin; Cugueró Escofet, Miquel Àngel; Cugueró Escofet, Miquel Àngel; Peralta, Antoni

    2011-01-01

    Using the simulation models a methodology was developed for leakage detection and localisation in a water distribution network [4]. Such methodology is based on fault detection and isolation techniques. Sensitivity matrix of pressures to leaks [8] is generated using simulation models [1]. Such models are available in water companies. The methodology showed promising results but two main issues appeared. Calibration in models and precision in sensors was required. Investment in sensors could b...

  9. Development of a vacuum leak test method for large-scale superconducting magnet test facilities

    International Nuclear Information System (INIS)

    Kawano, Katsumi; Hamada, Kazuya; Okuno, Kiyoshi; Kato, Takashi

    2006-01-01

    Japan Atomic Energy Agency (JAEA) has developed leak detection technology for liquid helium temperature experiments in large-scale superconducting magnet test facilities. In JAEA, a cryosorption pump that uses an absorbent cooled by liquid nitrogen with a conventional helium leak detector, is used to detect helium gas that is leaking from pressurized welded joints of pipes and valves in a vacuum chamber. The cryosorption pump plays the role of decreasing aerial components, such as water, nitrogen and oxygen, to increase the sensitivity of helium leak detection. The established detection sensitivity for helium leak testing is 10 -10 to 10 -9 Pam 3 /s. A total of 850 welded and mechanical joints inside the cryogenic test facility for the ITER Central Solenoid Model Coil (CSMC) experiments have been tested. In the test facility, 73 units of glass fiber-reinforced plastic (GFRP) insulation break are used. The amount of helium permeation through the GFRP was recorded during helium leak testing. To distinguish helium leaks from insulation-break permeation, the helium permeation characteristic of the GFRP part was measured as a function of the time of helium charging. Helium permeation was absorbed at 6 h after helium charging, and the detected permeation is around 10 -7 Pam 3 /s. Using the helium leak test method developed, CSMC experiments have been successfully completed. (author)

  10. High-voltage leak detection of a parenteral proteinaceous solution product packaged in form-fill-seal plastic laminate bags. Part 1. Method development and validation.

    Science.gov (United States)

    Damgaard, Rasmus; Rasmussen, Mats; Buus, Peter; Mulhall, Brian; Guazzo, Dana Morton

    2013-01-01

    In Part 1 of this three-part research series, a leak test performed using high-voltage leak detection (HVLD) technology, also referred to as an electrical conductivity and capacitance leak test, was developed and validated for container-closure integrity verification of a small-volume laminate plastic bag containing an aqueous solution for injection. The sterile parenteral product is the rapid-acting insulin analogue, insulin aspart (NovoRapid®/NovoLog®, by Novo Nordisk A/S, Bagsværd, Denmark). The aseptically filled and sealed package is designed to preserve product sterility through expiry. Method development and validation work incorporated positive control packages with a single hole laser-drilled through the laminate film of each bag. A unique HVLD method characterized by specific high-voltage and potentiometer set points was established for testing bags positioned in each of three possible orientations as they are conveyed through the instrument's test zone in each of two possible directions-resulting in a total of six different test method options. Validation study results successfully demonstrated the ability of all six methods to accurately and reliably detect those packages with laser-drilled holes from 2.5-11.2 μm in nominal diameter. Part 2 of this series will further explore HVLD test results as a function of package seal and product storage variables. The final Part 3 will report the impact of HVLD exposure on product physico-chemical stability. In this Part 1 of a three-part research series, a leak test method based on electrical conductivity and capacitance, called high voltage leak detection (HVLD), was used to find leaks in small plastic bags filled with an insulin pharmaceutical solution for human injection by Novo Nordisk A/S (Bagsværd, Denmark). To perform the test, the package is electrically grounded while being conveyed past an electrode linked to a high-voltage, low-amperage transformer. The instrument measures the current that passes

  11. Air-Leak Effects on Ear-Canal Acoustic Absorbance

    Science.gov (United States)

    Rasetshwane, Daniel M.; Kopun, Judy G.; Gorga, Michael P.; Neely, Stephen T.

    2015-01-01

    Objective: Accurate ear-canal acoustic measurements, such as wideband acoustic admittance, absorbance, and otoacoustic emissions, require that the measurement probe be tightly sealed in the ear canal. Air leaks can compromise the validity of the measurements, interfere with calibrations, and increase variability. There are no established procedures for determining the presence of air leaks or criteria for what size leak would affect the accuracy of ear-canal acoustic measurements. The purpose of this study was to determine ways to quantify the effects of air leaks and to develop objective criteria to detect their presence. Design: Air leaks were simulated by modifying the foam tips that are used with the measurement probe through insertion of thin plastic tubing. To analyze the effect of air leaks, acoustic measurements were taken with both modified and unmodified foam tips in brass-tube cavities and human ear canals. Measurements were initially made in cavities to determine the range of critical leaks. Subsequently, data were collected in ears of 21 adults with normal hearing and normal middle-ear function. Four acoustic metrics were used for predicting the presence of air leaks and for quantifying these leaks: (1) low-frequency admittance phase (averaged over 0.1–0.2 kHz), (2) low-frequency absorbance, (3) the ratio of compliance volume to physical volume (CV/PV), and (4) the air-leak resonance frequency. The outcome variable in this analysis was the absorbance change (Δabsorbance), which was calculated in eight frequency bands. Results: The trends were similar for both the brass cavities and the ear canals. ΔAbsorbance generally increased with air-leak size and was largest for the lower frequency bands (0.1–0.2 and 0.2–0.5 kHz). Air-leak effects were observed in frequencies up to 10 kHz, but their effects above 1 kHz were unpredictable. These high-frequency air leaks were larger in brass cavities than in ear canals. Each of the four predictor variables

  12. Doppler method leak detection for LMFBR steam generators. Pt. 1. Experimental results of bubble detection using small models

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi

    1999-01-01

    To prevent the expansion of the tube damage and to maintain structural integrity in the steam generators (SGs) of fast breeder reactors (FBRs), it is necessary to detect precisely and immediately the leakage of water from heat transfer tubes. Therefore, an active acoustic method was developed. Previous studies have revealed that in practical steam generators the active acoustic method can detect bubbles of 10 l/s within 10 seconds. To prevent the expansion of damage to neighboring tubes, it is necessary to detect smaller leakages of water from the heat transfer tubes. The Doppler method is designed to detect small leakages and to find the source of the leak before damage spreads to neighboring tubes. To evaluate the relationship between the detection sensitivity of the Doppler method and the bubble volume and bubble size, the structural shapes and bubble flow conditions were investigated experimentally, using a small structural model. The results show that the Doppler method can detect the bubbles under bubble flow conditions, and it is sensitive enough to detect small leakages within a short time. The doppler method thus has strong potential for the detection of water leakage in SGs. (author)

  13. Probabilistic pipe fracture evaluations for applications to leak-rate detection

    Energy Technology Data Exchange (ETDEWEB)

    Rahman, S; Wilkowski, G; Ghadiali, N [Battelle Columbus Labs., OH (United States)

    1993-12-31

    Stochastic pipe fracture evaluations are conducted for applications to leak-rate detection. A state-of-the-art review was first conducted to evaluate the adequacy of current deterministic models for thermo-hydraulic and elastic-plastic fracture analyses. Then a new probabilistic model was developed with the above deterministic models for structural reliability analysis of cracked piping systems and statistical characterization of crack morphology parameters, material properties of pipe, and crack location. The proposed models are then applied for computing conditional probability of failure for various nuclear piping systems in BWR and PWR plants. The PRAISE code was not used, and the probabilistic model is based on modern methods of stochastic mechanics, computationally far superior to Monte Carlo and Stratified Sampling methods used in PRAISE. 10 refs., 9 figs., 1 tab.

  14. Probabilistic pipe fracture evaluations for applications to leak-rate detection

    International Nuclear Information System (INIS)

    Rahman, S.; Wilkowski, G.; Ghadiali, N.

    1992-01-01

    Stochastic pipe fracture evaluations are conducted for applications to leak-rate detection. A state-of-the-art review was first conducted to evaluate the adequacy of current deterministic models for thermo-hydraulic and elastic-plastic fracture analyses. Then a new probabilistic model was developed with the above deterministic models for structural reliability analysis of cracked piping systems and statistical characterization of crack morphology parameters, material properties of pipe, and crack location. The proposed models are then applied for computing conditional probability of failure for various nuclear piping systems in BWR and PWR plants. The PRAISE code was not used, and the probabilistic model is based on modern methods of stochastic mechanics, computationally far superior to Monte Carlo and Stratified Sampling methods used in PRAISE. 10 refs., 9 figs., 1 tab

  15. ALIBABA, an assistance system for the detection of confinement leaks in a PWR reactor; ALIBABA, un systeme d`aide a la detection des voies de fuites du confinement sur un reacteur a eau sous pression

    Energy Technology Data Exchange (ETDEWEB)

    Bedier, P.O.; Libmann, M. [CEA Centre d`Etudes de Saclay, 91 - Gif-sur-Yvette (France). Dept. de Mecanique et de Technologie

    1995-12-31

    The objective of the Crisis Technical Center (CTC) of the French Institute for Nuclear Protection and Safety (IPSN) is to estimates the consequences of a given nuclear accident on the populations and the environment. ALIBABA is a data processing tool available at the CTC and devoted to the detection of confinement leaks in 900 MWe PWR reactors using the activity values measured by the captors of the installation. The heart of this expert system is a structural and functional representation of the different components directly involved in the leak detection (isolating valves, ventilation systems, electric boards etc..). This tool can manage the availability of each component to make qualitative and quantitative balance-sheets. This paper presents the ALIBABA software, an industrial prototype realized with the SPIRAL knowledge base systems generator at the CEA Reactor Studies and Applied Mathematics Service (SERMA) and commercialized by CRIL-Ingenierie Society. It describes the techniques used for the modeling of PWR systems and for the visualization of the survey. The functionality of the man-machine interface is discussed and the means used for the validation of the software are summarized. (J.S.). 6 refs.

  16. Estimation of leak rate through circumferential cracks in pipes in nuclear power plants

    Directory of Open Access Journals (Sweden)

    Jai Hak Park

    2015-04-01

    Full Text Available The leak before break (LBB concept is widely used in designing pipe lines in nuclear power plants. According to the concept, the amount of leaking liquid from a pipe should be more than the minimum detectable leak rate of a leak detection system before catastrophic failure occurs. Therefore, accurate estimation of the leak rate is important to evaluate the validity of the LBB concept in pipe line design. In this paper, a program was developed to estimate the leak rate through circumferential cracks in pipes in nuclear power plants using the Henry–Fauske flow model and modified Henry–Fauske flow model. By using the developed program, the leak rate was calculated for a circumferential crack in a sample pipe, and the effect of the flow model on the leak rate was examined. Treating the crack morphology parameters as random variables, the statistical behavior of the leak rate was also examined. As a result, it was found that the crack morphology parameters have a strong effect on the leak rate and the statistical behavior of the leak rate can be simulated using normally distributed crack morphology parameters.

  17. Leak detection in Phenix and Super Phenix steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Cambillard, E [Centre d' Etudes Nucleaires de Saclay, Gif-sur-Yvette (France)

    1978-10-01

    Water leak detection Phenix and Super Phenix steam generators is based on measurement of the hydrogen produced by the reaction of sodium with water. The hydrogen evolves in the sodium in which the steam generator tubes are completely immersed. Depending on service conditions, however (sodium temperature and flow velocity), the hydrogen may appear in the argon existing above the free levels. This is why, although the Phenix steam generators do not feature free levels, measurement systems were added to measure the hydrogen concentration in the argon in the expansion tanks. Super Phenix steam generators are fitted at their outlet with systems for measuring hydrogen in the sodium, and above their free level with a system for measuring hydrogen in the argon. The measurement systems have nickel tube probes connected to circuits kept under vacuum by an ion pump. The hydrogen partial pressure is measured by a mass spectrometer. Super Phenix measurement systems differ from Phenix systems essentially in the temperature regulation of the sodium reaching the nickel tube probes, and in the centralization of the supply and measurement systems of the ion pumps and mass spectrometers. This paper deals with description, calibration and operating conditions of the hydrogen detection systems in sodium and argon in Phenix and Super Phenix steam generators. (author)

  18. Deciding between compensated volume balance and real time transient models for pipeline leak detection system

    Energy Technology Data Exchange (ETDEWEB)

    Baptista, Renan Martins [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas. Div. de Explotacao]. E-mail: renan@cenpes.petrobras.com.br

    2000-07-01

    This paper describes a technical procedure to assess a software based leak detection system (LDS), by deciding between a simpler low cost, less effective product, having a fast installation and tuning, and a complex one with high cost and efficiency, which however takes a long time to be properly installed. This is a common decision among the pipeline operating companies, considering that the majority of the lines are short, with single phase liquid flow (which may include batches), basic communication system and instrumentation. Service companies offer realistic solutions for liquid flow, but usually designed to big pipeline networks, flowing multiple batches and allowing multiple fluid entrances and deliveries. Those solutions are sometimes impractical to short pipelines, due to its high cost, as well as long tuning procedures, complex instrumentation, communication and computer requirements. It is intended to approach here the best solution according to its cost. In a practical sense, it means to differentiate the various LDS techniques. Those techniques are available in a considerable number, and they are still spreading, according to the different scenarios. However, two most known and worldwide implemented techniques hold the majority of the market: the Compensated Volume Balance (CVB), which is less accurate, reliable and robust, but cheaper, simpler and faster to install, and the Real Time Transient Model (RTTM), which is very reliable, accurate and robust, but expensive and complex. This work will describe a way to define whether one can use or not a CVB in a pipeline. (author)

  19. Leveraging Social Norms to Improve Leak Resolution Outcomes Across Meter Classes:

    Science.gov (United States)

    Holleran, W.

    2016-12-01

    Over the past decade, utilities, governments, businesses, and nonprofits have come to realize that more than just financial considerations and information drive behavior. Social and psychological factors also play a significant role in shaping consumers' decisions and behaviors around resource use. Stakeholders have consequently turned their interest to behavioral science, a multidisciplinary field that draws from psychology, sociology, public health, and behavioral economics to explain the complex mechanisms that shape human behavior. When used strategically, behavioral science holds the potential to drive down resource use, drive up profits, and generate measurable gains in conservation and efficiency. WaterSmart will present on how the water sector can employ behavioral science to nudge residential rate-payers to use water more efficiently and help them save money. Utilities can use behavioral science to influence people's reaction to leaks. 5% of Single Family Residential (SFR) metered water use can be attributed to leaks. This value potentially skews even higher for MultiFamily (MF) and Commercial accounts given that it can get lost in the noise of daily consumption. Existing leak detection algorithms in the market are not sophisticated enough to detect leaks for a MF or Commercial property. Leveraging data from utilities on known leak events at MF and Commercial buildings allowed WaterSmart to train a machine learning model to identify key features in the load shape and accurately detect these types of water use events. The outcome of the model is a leak amount and confidence level for each irregular usage event. The model also incorporates record feedback from users on the type of leak event, and the accuracy of the alert. When WaterSmart leverages this data model with social norms messaging, we've been able to improve water demand management for MF and Commercial properties. Experiences from leak detection and resolution in the SFR space will also be

  20. Occurrence of occult CSF leaks during standard FESS procedures.

    Science.gov (United States)

    Bucher, S; Kugler, A; Probst, E; Epprecht, L; Stadler, R S; Holzmann, D; Soyka, M B

    2018-03-18

    To determine the incidence of occult cerebrospinal fluid leaks (CSF) after functional endoscopic sinus surgery (FESS) and to evaluate the diagnostic performance of beta2-transferrin in blood-contaminated conditions. Prospective cohort study. An analysis of 57 intraoperative samples using hydrogel 6 beta2-transferrin assay after FESS was undertaken. In case of CSF positive samples and continuing rhinorrhea, reanalysis after more than 1 year was conducted. In-vivo analysis of a primary spontaneous CSF leak sample took place to verify difficulties in detecting beta2-transferrin in blood-contaminated settings. Own titrations were performed to evaluate detection limits of CSF by beta2-transferrin and beta-trace protein assays in these settings. An incidence of 13% for occult CSF leaks after FESS was found. In blood-contaminated conditions, routine beta2-transferrin assays showed low sensitivity. In over 1 year follow-up, all samples were negative for CSF and none of them developed clinical relevant CSF leaks or meningitis. Occult and clinically irrelevant CSF leaks do occur in a significant proportion of patients during and shortly after FESS. Intra- and postoperatively, routine beta2-transferrin assays show low sensitivity. They should not be used in these settings. The clinical course of patients with occult CSF leaks indicated possibility of an uneventful follow-up.