WorldWideScience

Sample records for leak detection systems

  1. Safe Detection System for Hydrogen Leaks

    Energy Technology Data Exchange (ETDEWEB)

    Lieberman, Robert A. [Intelligent Optical Systems, Inc., Torrance, CA (United States); Beshay, Manal [Intelligent Optical Systems, Inc., Torrance, CA (United States)

    2012-02-29

    Hydrogen is an "environmentally friendly" fuel for future transportation and other applications, since it produces only pure ("distilled") water when it is consumed. Thus, hydrogen-powered vehicles are beginning to proliferate, with the total number of such vehicles expected to rise to nearly 100,000 within the next few years. However, hydrogen is also an odorless, colorless, highly flammable gas. Because of this, there is an important need for hydrogen safety monitors that can warn of hazardous conditions in vehicles, storage facilities, and hydrogen production plants. To address this need, IOS has developed a unique intrinsically safe optical hydrogen sensing technology, and has embodied it in detector systems specifically developed for safety applications. The challenge of using light to detect a colorless substance was met by creating chemically-sensitized optical materials whose color changes in the presence of hydrogen. This reversible reaction provides a sensitive, reliable, way of detecting hydrogen and measuring its concentration using light from low-cost LEDs. Hydrogen sensors based on this material were developed in three completely different optical formats: point sensors ("optrodes"), integrated optic sensors ("optical chips"), and optical fibers ("distributed sensors") whose entire length responds to hydrogen. After comparing performance, cost, time-to-market, and relative market need for these sensor types, the project focused on designing a compact optrode-based single-point hydrogen safety monitor. The project ended with the fabrication of fifteen prototype units, and the selection of two specific markets: fuel cell enclosure monitoring, and refueling/storage safety. Final testing and development of control software for these markets await future support.

  2. High Altitude Aerial Natural Gas Leak Detection System

    Energy Technology Data Exchange (ETDEWEB)

    Richard T. Wainner; Mickey B. Frish; B. David Green; Matthew C. Laderer; Mark G. Allen; Joseph R. Morency

    2006-12-31

    The objective of this program was to develop and demonstrate a cost-effective and power-efficient advanced standoff sensing technology able to detect and quantify, from a high-altitude (> 10,000 ft) aircraft, natural gas leaking from a high-pressure pipeline. The advanced technology is based on an enhanced version of the Remote Methane Leak Detector (RMLD) platform developed previously by Physical Sciences Inc. (PSI). The RMLD combines a telecommunications-style diode laser, fiber-optic components, and low-cost DSP electronics with the well-understood principles of Wavelength Modulation Spectroscopy (WMS), to indicate the presence of natural gas located between the operator and a topographic target. The transceiver transmits a laser beam onto a topographic target and receives some of the laser light reflected by the target. The controller processes the received light signal to deduce the amount of methane in the laser's path. For use in the airborne platform, we modified three aspects of the RMLD, by: (1) inserting an Erbium-doped optical fiber laser amplifier to increase the transmitted laser power from 10 mW to 5W; (2) increasing the optical receiver diameter from 10 cm to 25 cm; and (3) altering the laser wavelength from 1653 nm to 1618 nm. The modified RMLD system provides a path-integrated methane concentration sensitivity {approx}5000 ppm-m, sufficient to detect the presence of a leak from a high capacity transmission line while discriminating against attenuation by ambient methane. In ground-based simulations of the aerial leak detection scenario, we demonstrated the ability to measure methane leaks within the laser beam path when it illuminates a topographic target 2000 m away. We also demonstrated simulated leak detection from ranges of 200 m using the 25 cm optical receiver without the fiber amplifier.

  3. Towards aerial natural gas leak detection system based on TDLAS

    Science.gov (United States)

    Liu, Shuyang; Zhou, Tao; Jia, Xiaodong

    2014-11-01

    Pipeline leakage is a complex scenario for sensing system due to the traditional high cost, low efficient and labor intensive detection scheme. TDLAS has been widely accepted as industrial trace gas detection method and, thanks to its high accuracy and reasonable size, it has the potential to meet pipeline gas leakage detection requirements if it combines with the aerial platform. Based on literature study, this paper discussed the possibility of applying aerial TDLAS principle in pipeline gas leak detection and the key technical foundation of implementing it. Such system is able to result in a high efficiency and accuracy measurement which will provide sufficient data in time for the pipeline leakage detection.

  4. Optoelectronic leak detection system for monitoring subsea structures

    Science.gov (United States)

    Moodie, D.,; Costello, L.; McStay, D.

    2010-04-01

    Leak detection and monitoring on subsea structures is an area of increasing interest for the detection and monitoring of production and control fluids for the oil and gas industry. Current techniques such as capacitive (dielectric) based measurement or passive acoustic systems have limitations and we report here an optoelectronic solution based upon fluorescence spectroscopy to provide a permanent monitoring solution. We report here a new class of optoelectronic subsea sensor for permanent, real time monitoring of hydrocarbon production systems. The system is capable of detecting small leaks of production or hydraulic fluid (ppm levels) over distances of 4-5 meters in a subsea environment. Ideally systems designed for such applications should be capable of working at depths of up to 3000m unattended for periods of 20+ years. The system uses advanced single emitter LED technology to meet the challenges of lifetime, power consumption, spatial coverage and delivery of a cost effective solution. The system is designed for permanent deployment on Christmas tree (XT), subsea processing systems (SPS) and associated equipment to provide enhanced leak detection capability.

  5. A hydrogen leak detection system for aerospace and commercial applications

    Science.gov (United States)

    Hunter, Gary W.; Makel, D. B.; Jansa, E. D.; Patterson, G.; Cova, P. J.; Liu, C. C.; Wu, Q. H.; Powers, W. T.

    1995-10-01

    Leaks on the space shuttle while on the launch pad have generated interest in hydrogen leak monitoring technology. Microfabricated hydrogen sensors are being fabricated at Case Western Reserve University (CWRU) and tested at NASA Lewis Research Center (LeRC). These sensors have been integrated into hardware and software designed by Aerojet. This complete system allows for multipoint leak monitoring designed to provide leak source and magnitude information in real time. The monitoring system processes data from the hydrogen sensors and presents the operator with a visual indication of the leak location and magnitude. Although the leak monitoring system was designed for hydrogen propulsion systems, the possible applications of this monitoring system are wide ranged. This system is in operation in an automotive application which requires high sensitivity to hydrogen.

  6. Distributed Leak Detection System Using Structure-Borne Noise Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Manned spacecraft are vulnerable to air leaks caused by micrometeorite and space debris impact. The ability to detect and quickly locate and mitigate a pressure...

  7. Distributed Leak Detection System Using Structure-Borne Noise Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Manned spacecraft are vulnerable to air leaks caused by micrometeoroid and space debris impact. The ability to detect and quickly locate and mitigate a pressure...

  8. System for Steam Leak Detection by using CCTV Camera

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Young Chul; Lee, Min Soo; Choi, Hui Ju [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Son, Ki Sung; Jeon, Hyeong Seop [SAEAN.Co., Seoul (Korea, Republic of)

    2012-05-15

    There are many pipes in the secondary cooling systems of nuclear power plants and coal-fired power plants. In these pipes, high pressure fluids are moving with at high velocity, which can cause steam leakage due to pipe thinning. Steam leakage is one of the major issues for the structural fracture of pipes. Therefore, a method to inspect a large area of piping systems quickly and accurately is needed. Steam leakage is almost invisible, because the flow has very high velocity and pressure. Therefore, it is very difficult to detect a steam leakage. In this paper, we proposed the method for detecting steam leakage using image signal processing. Our basic idea comes from a heat shimmer, which shines with a soft light that looks as if it is being shaken slightly. To test the performance of this technique, experiments have been performed for a steam generator. Results show that the proposed technique is quite powerful for steam leak detection

  9. Leak detection and localization system through acoustics; Sistema de deteccao e localizacao de vazamentos por acustica

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, Julio [Aselco Automacao, Sao Paulo, SP (Brazil)

    2003-07-01

    Acoustic Leak Detection Systems (ALDS) are used on both liquid and gas pipelines as well as multi-phase flow pipelines to detect leaks quickly and provide a means of limiting product loss. The real-time acoustic signal is continuously compared against signature leak profiles for the particular operating and geometric conditions. These profiles were developed from a database established from over 20 years of experimental and field leak tests. This technique not only drastically reduces the false alarm rate, but also significantly improves the sensitivity and leak location accuracy. This system will also detect leaks with shut-in flow (zero flow rate in the pipeline). With the use of GPS (Global Positioning System) it not only improves leak location accuracy, but also allows for continuous leak detection during the loss of communications. (author)

  10. Mobile Sensor Networks for Leak and Backflow Detection in Water Distribution Systems

    KAUST Repository

    Suresh, M. Agumbe

    2014-05-01

    Leak and backflow detection are essential aspects of Water Distribution System (WDS) monitoring. Most existing solutions for leak/backflow detection in WDSs focus on the placement of expensive static sensors located strategically. In contrast to these, we propose a solution whereby mobile sensors (i.e., their movement aided only by the inherent water flow in the system) detect leaks/backflow. Information about the leaks/backflow is collected from the sensors either by physically capturing them, or through wireless communication. Specifically, we propose models to maximize leak/backflow detection given a cost constraint (a limit on the number of sensors). Through extensive simulations, we demonstrate the superior performance of our proposed solution when compared with the state of the art solutions (e.g., algorithms/protocols and analysis).

  11. Flight Testing of an Advanced Airborne Natural Gas Leak Detection System

    Energy Technology Data Exchange (ETDEWEB)

    Dawn Lenz; Raymond T. Lines; Darryl Murdock; Jeffrey Owen; Steven Stearns; Michael Stoogenke

    2005-10-01

    ITT Industries Space Systems Division (Space Systems) has developed an airborne natural gas leak detection system designed to detect, image, quantify, and precisely locate leaks from natural gas transmission pipelines. This system is called the Airborne Natural Gas Emission Lidar (ANGEL) system. The ANGEL system uses a highly sensitive differential absorption Lidar technology to remotely detect pipeline leaks. The ANGEL System is operated from a fixed wing aircraft and includes automatic scanning, pointing system, and pilot guidance systems. During a pipeline inspection, the ANGEL system aircraft flies at an elevation of 1000 feet above the ground at speeds of between 100 and 150 mph. Under this contract with DOE/NETL, Space Systems was funded to integrate the ANGEL sensor into a test aircraft and conduct a series of flight tests over a variety of test targets including simulated natural gas pipeline leaks. Following early tests in upstate New York in the summer of 2004, the ANGEL system was deployed to Casper, Wyoming to participate in a set of DOE-sponsored field tests at the Rocky Mountain Oilfield Testing Center (RMOTC). At RMOTC the Space Systems team completed integration of the system and flew an operational system for the first time. The ANGEL system flew 2 missions/day for the duration for the 5-day test. Over the course of the week the ANGEL System detected leaks ranging from 100 to 5,000 scfh.

  12. Detection and location of leaks in district heating steam systems: Survey and review of current technology and practices

    Energy Technology Data Exchange (ETDEWEB)

    Kupperman, D.S.; Raptis, A.C.; Lanham, R.N.

    1992-03-01

    This report presents the results of a survey undertaken to identify and characterize current practices for detecting and locating leaks in district heating systems, particular steam systems. Currently used technology and practices are reviewed. In addition, the survey was used to gather information that may be important for the application of acoustic leak detection. A few examples of attempts to locate leaks in steam and hot water pipes by correlation of acoustic signals generated by the leaks are also discussed.

  13. Analytical study of the performance of a geomembrane leak detection system.

    Science.gov (United States)

    Lugli, Francesco; Mahler, Claudio Fernando

    2016-05-01

    The electrical detection of leaks in geomembranes is a method that allows identifying leakage of contaminants in lined facilities (e.g. sanitary landfills, pollutant ponds, etc.). The procedure in the field involves placing electrodes above and below the geomembrane, to generate an electrical current, which in turn engenders an electric potential distribution in the protective layer (generally a clayey soil). The electric potential will be greater in areas with higher current density, i.e. near leaks. In this study, we combined models from the literature to carry out a parametric analysis to identify the variables that most influence the amplitude of the electrical signals produced by leaks. The basic hypothesis is that the electrical conduction phenomena in a liner system could be depicted by a direct current circuit. After determining the value of the current at the leak, we calculated the electric potential distribution according to the model of Darilek and Laine. This enabled analysing the sensitivity of the parameters, which can be useful in the design of landfills and facilitate the location of leaks. This study showed that geomembranes with low electrical resistance (owing to low thickness, low resistivity, or extensive area) can hinder the leak detection process. In contrast, low thickness and high resistivity of the protection layer magnify the leak signal.

  14. Real-Time Model-Based Leak-Through Detection within Cryogenic Flow Systems

    Science.gov (United States)

    Walker, M.; Figueroa, F.

    2015-01-01

    The timely detection of leaks within cryogenic fuel replenishment systems is of significant importance to operators on account of the safety and economic impacts associated with material loss and operational inefficiencies. Associated loss in control of pressure also effects the stability and ability to control the phase of cryogenic fluids during replenishment operations. Current research dedicated to providing Prognostics and Health Management (PHM) coverage of such cryogenic replenishment systems has focused on the detection of leaks to atmosphere involving relatively simple model-based diagnostic approaches that, while effective, are unable to isolate the fault to specific piping system components. The authors have extended this research to focus on the detection of leaks through closed valves that are intended to isolate sections of the piping system from the flow and pressurization of cryogenic fluids. The described approach employs model-based detection of leak-through conditions based on correlations of pressure changes across isolation valves and attempts to isolate the faults to specific valves. Implementation of this capability is enabled by knowledge and information embedded in the domain model of the system. The approach has been used effectively to detect such leak-through faults during cryogenic operational testing at the Cryogenic Testbed at NASA's Kennedy Space Center.

  15. The genetic-algorithm-enhanced blind system identification for water distribution pipeline leak detection

    Science.gov (United States)

    Yang, Jin; Wen, Yumei; Li, Ping

    2007-07-01

    The conventional leak location is based on the correlation of leak acoustic signals acquired spatially separately. By correlation, the time lag is estimated for localizing the leakage. In these methods, the detection distance is a prerequisite that has to be known beforehand. However, in practice, this prerequisite is not always satisfied. In this case, the correlation-based methods are not feasible. Actually, the acquired signals contain the characteristics related to the acoustic propagation channels; thus the blind system identification strategy is applied to estimate the transmission performances of acoustic channels. Then the times due to the propagation of the leak source signal travelling from the leak point to sensors are determined. In this way, for leak location, the detection distance is no longer a prerequisite. In blind system identification, due to the long impulse responses of the leak acoustic channels, the channels are inevitably ill conditioned and sensitive to the initial values. To overcome the ill conditions, the overlap-save and cross-correlation fitting techniques are utilized to identify the long impulse sequences under a built constraint. In order to avoid converging to the local minima, the genetic algorithm is used to minimize the cost functions. The practical detection results show the validity of the proposed scheme.

  16. Aspects of leak detection

    Energy Technology Data Exchange (ETDEWEB)

    Chivers, T.C. [Berkeley Technology Centre, Glos (United Kingdom)

    1997-04-01

    A requirement of a Leak before Break safety case is that the leakage from the through wall crack be detected prior to any growth leading to unacceptable failure. This paper sets out to review some recent developments in this field. It does not set out to be a comprehensive guide to all of the methods available. The discussion concentrates on acoustic emission and how the techniques can be qualified and deployed on operational plant.

  17. Sensors for Fluid Leak Detection

    Directory of Open Access Journals (Sweden)

    Gonzalo Pajares Martinsanz

    2015-02-01

    Full Text Available Fluid leak detection represents a problem that has attracted the interest of researchers, but not exclusively because in industries and services leaks are frequently common. Indeed, in water or gas supplies, chemical or thermal plants, sea-lines or cooling/heating systems leakage rates can cause important economic losses and sometimes, what it is more relevant, environmental pollution with human, animal or plant lives at risk. This last issue has led to increased national and international regulations with different degrees of severity regarding environmental conservation.[...

  18. Leak detection/verification

    Energy Technology Data Exchange (ETDEWEB)

    Krhounek, V.; Zdarek, J.; Pecinka, L. [Nuclear Research Institute, Rez (Czech Republic)

    1997-04-01

    Loss of coolant accident (LOCA) experiments performed as part of a Leak Before Break (LBB) analysis are very briefly summarized. The aim of these experiments was to postulate the leak rates of the coolant. Through-wall cracks were introduced into pipes by fatigue cycling and hydraulically loaded in a test device. Measurements included coolant pressure and temperature, quantity of leaked coolant, displacement of a specimen, and acoustic emission. Small cracks were plugged with particles in the coolant during testing. It is believed that plugging will have no effect in cracks with leak rates above 35 liters per minute. The leak rate safety margin of 10 is sufficient for cracks in which the leak rate is more than 5 liters per minute.

  19. Leaking Chaotic Systems

    CERN Document Server

    Altmann, Eduardo G; Tél, Tamás

    2013-01-01

    There are numerous physical situations in which a hole or leak is introduced in an otherwise closed chaotic system. The leak can have a natural origin, it can mimic measurement devices, and it can also be used to reveal dynamical properties of the closed system. In this paper we provide an unified treatment of leaking systems and we review applications to different physical problems, both in the classical and quantum pictures. Our treatment is based on the transient chaos theory of open systems, which is essential because real leaks have finite size and therefore estimations based on the closed system differ essentially from observations. The field of applications reviewed is very broad, ranging from planetary astronomy and hydrodynamical flows, to plasma physics and quantum fidelity. The theory is expanded and adapted to the case of partial leaks (partial absorption/transmission) with applications to room acoustics and optical microcavities in mind. Simulations in the lima .con family of billiards illustrate...

  20. Leak detection capability in CANDU reactors

    Energy Technology Data Exchange (ETDEWEB)

    Azer, N.; Barber, D.H.; Boucher, P.J. [and others

    1997-04-01

    This paper addresses the moisture leak detection capability of Ontario Hydro CANDU reactors which has been demonstrated by performing tests on the reactor. The tests confirmed the response of the annulus gas system (AGS) to the presence of moisture injected to simulate a pressure tube leak and also confirmed the dew point response assumed in leak before break assessments. The tests were performed on Bruce A Unit 4 by injecting known and controlled rates of heavy water vapor. To avoid condensation during test conditions, the amount of moisture which could be injected was small (2-3.5 g/hr). The test response demonstrated that the AGS is capable of detecting and annunciating small leaks. Thus confidence is provided that it would alarm for a growing pressure tube leak where the leak rate is expected to increase to kg/hr rapidly. The measured dew point response was close to that predicted by analysis.

  1. Research and development of a high-temperature helium-leak detection system (joint research). Part 1 survey on leakage events and current leak detection technology

    Energy Technology Data Exchange (ETDEWEB)

    Sakaba, Nariaki; Nakazawa, Toshio; Kawasaki, Kozo [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment; Urakami, Masao; Saisyu, Sadanori [Japan Atomic Power Co., Tokyo (Japan)

    2003-03-01

    In High Temperature Gas-cooled Reactors (HTGR), the detection of leakage of helium at an early stage is very important for the safety and stability of operations. Since helium is a colourless gas, it is generally difficult to identify the location and the amount of leakage when very little leakage has occurred. The purpose of this R and D is to develop a helium leak detection system for the high temperature environment appropriate to the HTGR. As the first step in the development, this paper describes the result of surveying leakage events at nuclear facilities inside and outside Japan and current gas leakage detection technology to adapt optical-fibre detection technology to HTGRs. (author)

  2. Intelligent leak detection system for oil pipelines; Sistema inteligente para deteccao de vazamentos em dutos de petroleo

    Energy Technology Data Exchange (ETDEWEB)

    Freitas, Ricardo Dantas Gadelha de [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil)

    2003-07-01

    One of the most challenging tasks in an oil field is implementation of a software-based leak detection system on a multi-phase flow pipeline. This paper will discuss implementation of a leak detection system in a particular oil field using state-of-the-art signal processing techniques to apply to the data collected in a oil pipeline. This leak detection system is still in development and uses a more practical approach to the problem than traditional methods and was implemented on a PC under the Windows operating system. Windowing, joint time-frequency analysis and wavelets were considered to develop methods of detecting leaks by watching for the wavefront. The idea behind these techniques is to cut the signal of interest into several parts and then analyze the parts separately. It is impossible to know the exact frequency and the exact time of occurrence of the leak frequency in a signal. In other words, a leak signal can simply not be represented as a point in the time-frequency space. It is very important how one cuts the signal to implement the analysis. The wavelet transform or wavelet analysis is probably the most recent solution to overcome the shortcomings of the Fourier transform. So, this paper shows some tests and how these techniques are being implementing during the development of the system. (author)

  3. 49 CFR 195.134 - CPM leak detection.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false CPM leak detection. 195.134 Section 195.134... PIPELINE Design Requirements § 195.134 CPM leak detection. This section applies to each hazardous liquid... computational pipeline monitoring (CPM) leak detection system and each replaced component of an existing...

  4. 49 CFR 195.444 - CPM leak detection.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false CPM leak detection. 195.444 Section 195.444... PIPELINE Operation and Maintenance § 195.444 CPM leak detection. Each computational pipeline monitoring (CPM) leak detection system installed on a hazardous liquid pipeline transporting liquid in...

  5. Whole new ball game : pipeline leak detection system undergoes first field trial

    Energy Technology Data Exchange (ETDEWEB)

    Marsters, S.

    2007-07-15

    This article described an innovative and portable technology that detects leaks in oil and gas pipelines. Pure Technologies Ltd. completed the first field trial of its SoundPrint SmartBall, a free-swimming foam ball with an embedded sensor in an aluminum core that detects leaks as the ball moves through the pipe. The technology is based on the premise that sound is released when a pressurized fluid is escaping. The field trial was performed over 18 kilometres of a 10-inch crude oil pipeline in Texas. The SmartBall was first sent through a pipeline without any artificial leaks. It was then sent through a pipeline with an artificial leak constructed at one of the block valves. The SmartBall was able to detect the artificial leak from hundreds of metres away. The device was deployed and retrieved without incident by pipeline operations personnel using existing pigging infrastructure. It was determined that the device can detect leaks of less than 3.78 litres per minute at an operating pressure of 8.6 bars. The size of the SmartBall is generally between 50 to 80 per cent of the diameter of the pipeline and depends on other factors such as location of in-line vales, the size of the appurtenances through which the ball is inserted and retrieved and the presence of other lateral lines. The device records acoustic information as it travels in the pipe. Alternatively, transducers that emit an acoustic pulse can be installed on pipe appurtenances. The leaks can be located by analyzing the relative arrival time of pulses. The device can operate for up to 40 hours, enough to travel 100 kilometres in a single deployment. Pure Technologies is now working on getting this new technology accepted by the industry. 2 figs.

  6. Recent Progress in Technology of Leak detection

    Energy Technology Data Exchange (ETDEWEB)

    Jung, H. K.; Kim, S. H.; Cho, J. W.; Joo, Y. S.; Yang, D. J

    2005-07-15

    It is very important to check for leakage points of fluids and gases on primary pressure boundary of nuclear power plants in order to maintain and manage various structures safely. Even though much investigation has been performed by a number of researchers, there are a lot of problems to detect the leakage under some areas to which people can not approach. In particular, it is certainly necessary to find the leakage point in order to repair and replace the pressure boundaries. In this report, the basic principle and application situations for the development of the leak detection system which can detect micro-leaks are introduced. As the technologies and performances of recent sensors have been improving, the application range of leak detection has been increasing steadily. Therefore the sensor technologies written in this report will be able to contribute to nuclear safety to detect the leakage rate and the leakage point with an on-line monitoring system in the near future.

  7. Probabilistic pipe fracture evaluations for leak-rate-detection applications

    Energy Technology Data Exchange (ETDEWEB)

    Rahman, S.; Ghadiali, N.; Paul, D.; Wilkowski, G. [Battelle, Columbus, OH (United States)

    1995-04-01

    Regulatory Guide 1.45, {open_quotes}Reactor Coolant Pressure Boundary Leakage Detection Systems,{close_quotes} was published by the U.S. Nuclear Regulatory Commission (NRC) in May 1973, and provides guidance on leak detection methods and system requirements for Light Water Reactors. Additionally, leak detection limits are specified in plant Technical Specifications and are different for Boiling Water Reactors (BWRs) and Pressurized Water Reactors (PWRs). These leak detection limits are also used in leak-before-break evaluations performed in accordance with Draft Standard Review Plan, Section 3.6.3, {open_quotes}Leak Before Break Evaluation Procedures{close_quotes} where a margin of 10 on the leak detection limit is used in determining the crack size considered in subsequent fracture analyses. This study was requested by the NRC to: (1) evaluate the conditional failure probability for BWR and PWR piping for pipes that were leaking at the allowable leak detection limit, and (2) evaluate the margin of 10 to determine if it was unnecessarily large. A probabilistic approach was undertaken to conduct fracture evaluations of circumferentially cracked pipes for leak-rate-detection applications. Sixteen nuclear piping systems in BWR and PWR plants were analyzed to evaluate conditional failure probability and effects of crack-morphology variability on the current margins used in leak rate detection for leak-before-break.

  8. A survey on the state-of-the-technique on software based pipeline leak detection systems

    Energy Technology Data Exchange (ETDEWEB)

    Baptista, Renan Martins [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil). Centro de Pesquisas. Div. de Explotacao]. E-mail: renan@cenpes.petrobras.com.br

    2000-07-01

    This paper describes a general technical survey on software based leak detection systems (LDS), approaching its main technological features, the operational situations where they are feasible, and the scenarios within the Brazilian pipeline network. The decision on what LDS to choose for a given pipeline is a matter of cost, suitability and feasibility. A simpler low cost, less effective product, but with a fast installation and tuning procedure, may be more suitable for a given operational site (pipeline configuration, kind of fluid, quality of instrumentation and communication), than a complex, high cost, efficient product, but taking a long time to be properly installed. Some other may really have a level of complexity that will require a more sophisticated system. A few number of them will simply not be suitable to have a LDS: it may be caused by the poor quality or absence of instrumentation, or, the worst case, due to the lack of technology to approach that specific case, e. g., multiphase flow lines, or those lines that commonly operates in slack condition. It is intended to approach here the general state-of-the-technique and make some initial comments on the costs. (author)

  9. Deciding between compensated volume balance and real time transient models for pipeline leak detection system

    Energy Technology Data Exchange (ETDEWEB)

    Baptista, Renan Martins [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas. Div. de Explotacao]. E-mail: renan@cenpes.petrobras.com.br

    2000-07-01

    This paper describes a technical procedure to assess a software based leak detection system (LDS), by deciding between a simpler low cost, less effective product, having a fast installation and tuning, and a complex one with high cost and efficiency, which however takes a long time to be properly installed. This is a common decision among the pipeline operating companies, considering that the majority of the lines are short, with single phase liquid flow (which may include batches), basic communication system and instrumentation. Service companies offer realistic solutions for liquid flow, but usually designed to big pipeline networks, flowing multiple batches and allowing multiple fluid entrances and deliveries. Those solutions are sometimes impractical to short pipelines, due to its high cost, as well as long tuning procedures, complex instrumentation, communication and computer requirements. It is intended to approach here the best solution according to its cost. In a practical sense, it means to differentiate the various LDS techniques. Those techniques are available in a considerable number, and they are still spreading, according to the different scenarios. However, two most known and worldwide implemented techniques hold the majority of the market: the Compensated Volume Balance (CVB), which is less accurate, reliable and robust, but cheaper, simpler and faster to install, and the Real Time Transient Model (RTTM), which is very reliable, accurate and robust, but expensive and complex. This work will describe a way to define whether one can use or not a CVB in a pipeline. (author)

  10. Detection of interstate liquids pipeline leaks: Feasibility evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Dietz, R.N.; Senum, G.I.

    1998-10-20

    The approximately 200,000-mile fuel pipeline system in the US operates at flow rates up to 2.5 {times} 10{sup 6} gallons per hour (GPH). Most commercial technologies only provide on-line leak detection at about 0.3% of flow rate, i.e., about 7,500 GPH or larger. Detection of leaks at about 1 GPH or so is desirable both from a regulatory and leak-prevention standpoint. Brookhaven`s commercially-accepted perfluorocarbon tracer (PFT) technology for underground leak detection of utility industry dielectric fluids at leak rates less than 0.1 GPH, with new enhancements, will be able to cost-effectively detect fuel pipeline system leaks to about 1 GPH--3 orders-of-magnitude better than any on-line system. The magnitude of detected leaks would be calculable as well. Proposed mobile surveys (such as those used periodically in the gas pipeline industry) at about 110 to 120 miles per day would allow such small leaks to be detected at 10-ppb tagging levels (less than $1,500 of PFT for a 48-hour tag at the maximum transport rate) under worst-case meteorological dispersion conditions. Smaller leaks could be detected by proportionately larger tagging concentrations. Leaks would be pinpointed by subsequent conventional barholing and vapor analyses. There are no health nor safety issues associated with the use of the proposed technological approach nor any consequential environmental impacts associated with the proposed magnitudes of PFT tagging.

  11. HIGH RESOLUTION RESISTIVITY LEAK DETECTION DATA PROCESSING & EVALUATION MEHTODS & REQUIREMENTS

    Energy Technology Data Exchange (ETDEWEB)

    SCHOFIELD JS

    2007-10-04

    This document has two purposes: {sm_bullet} Describe how data generated by High Resolution REsistivity (HRR) leak detection (LD) systems deployed during single-shell tank (SST) waste retrieval operations are processed and evaluated. {sm_bullet} Provide the basic review requirements for HRR data when Hrr is deployed as a leak detection method during SST waste retrievals.

  12. DETECTION OF INTERSTATE LIQUIDS PIPELINE LEAKS: FEASIBILITY EVALUATION.

    Energy Technology Data Exchange (ETDEWEB)

    DIETZ,R.N.

    1998-10-20

    The approximately 200,000-mile fuel pipeline system in the U.S. operates at flow rates up to 2.5 x 10{sup 6}gallons per hour (GPH). Most commercial technologies only provide on-line leak detection at about 0.3% of flow rate, i.e., about 7,500 GPH or larger. Detection of leaks at about 1 GPH or so is desirable both from a regulatory and leak-prevention standpoint. Brookhaven's commercially-accepted perfluorocarbon tracer (PFT) technology for underground leak detection of utility industry dielectric fluids at leak rates less than 0.1 GPH, with new enhancements, will be able to cost-effectively detect fuel pipeline system leaks to about 1 GPH--3 orders-of-magnitude better than any on-line system. The magnitude of detected leaks would be calculable as well. Proposed mobile surveys (such as those used periodically in the gas pipeline industry) at about 110 to 120 miles per day would allow such small leaks to be detected at 10-ppb tagging levels (less than $1,500 of PFT for a 48-hour tag at the maximum transport rate) under worst-case meteorological dispersion conditions. Smaller leaks could be detected by proportionately larger tagging concentrations. Leaks would be pinpointed by subsequent conventional barholing and vapor analyses. There are no health nor safety issues associated with the use of the proposed technological approach nor any consequential environmental impacts associated with the proposed magnitudes of PFT tagging.

  13. Elevation profile influence at key contractual performance parameters for LDS (Leak Detection Systems) based on compensated volume balance

    Energy Technology Data Exchange (ETDEWEB)

    Liebenberg, Lieb [TRANSNET Pipeline, Durban (South Africa); Bueno, David; Passos, Rafaela [KANOPUS Consulting, Rio de Janeiro, RJ (Brazil)

    2009-07-01

    This paper describes and discusses procedures and correlations to estimate performance parameters for Leak Detection Systems based on Compensation Volume Balance, at the portions not usually covered by international standards (like, API RP 1130). These parameters include: minimum acceptable leakage to be detected, under steady state conditions, based on flow measurement uncertainty, observed for both pipeline head and tail; an actual flow rate uncertainty against the one informed by the flow meter manufacturer documentation; the reference flow rate for steady state conditions; and the sensitivity one may expect for the system against a given probability of false alarms (i.e., the ways to correlate reliability, the main performance parameter as per API RP 1130 and sensitivity, the second one). A question usually not considered is: how the elevation profile may affect some of these parameters. That is the second main objective addressed herein, with actual examples employed in a South African multi product pipeline. (author)

  14. Leak detection in pipelines using cepstrum analysis

    Science.gov (United States)

    Taghvaei, M.; Beck, S. B. M.; Staszewski, W. J.

    2006-02-01

    The detection and location of leaks in pipeline networks is a major problem and the reduction of these leaks has become a major priority for pipeline authorities around the world. Although the reasons for these leaks are well known, some of the current methods for locating and identifying them are either complicated or imprecise; most of them are time consuming. The work described here shows that cepstrum analysis is a viable approach to leak detection and location in pipeline networks. The method uses pressure waves caused by quickly opening and closing a solenoid valve. Due to their simplicity and robustness, transient analyses provide a plausible route towards leak detection. For this work, the time domain signals of these pressure transients were obtained using a single pressure transducer. These pressure signals were first filtered using discrete wavelets to remove the dc offset, and the low and high frequencies. They were then analysed using a cepstrum method which identified the time delay between the initial wave and its reflections. There were some features in the processed results which can be ascribed to features in the pipeline network such as junctions and pipe ends. When holes were drilled in the pipe, new peaks occurred which identified the presence of a leak in the pipeline network. When tested with holes of different sizes, the amplitude of the processed peak was seen to increase as the cube root of the leak diameter. Using this method, it is possible to identify leaks that are difficult to find by other methods as they are small in comparison with the flow through the pipe.

  15. Local Leak Detection and Health Monitoring of Pressurized Tanks

    Science.gov (United States)

    Polzin, Kurt; Witherow, William; Korman, Valentin; Sinko, John; Hendrickson, Adam

    2011-01-01

    An optical gas-detection sensor safely monitors pressurized systems (such as cryogenic tanks) and distribution systems for leaks. This sensor system is a fiber-coupled, solid optical body interferometer that allows for the miniaturized sensing element of the device to be placed in the smallest of recesses, and measures a wide range of gas species and densities (leaks). The deflection of the fringe pattern is detected and recorded to yield the time-varying gas density in the gap. This technology can be used by manufacturers or storage facilities with toxic, hazardous, or explosive gases. The approach is to monitor the change in the index of refraction associated with low-level gas leaks into a vacuum environment. The completion of this work will provide NASA with an enabling capability to detect gas system leaks in space, and to verify that pressurized systems are in a safe (i.e. non-leaking) condition during manned docking and transit operations. By recording the output of the sensor, a time-history of the leak can be constructed to indicate its severity. Project risk is mitigated by having several interferometric geometries and detection techniques available, each potentially leveraging hardware and lessons learned to enhance detectability.

  16. ISS Ammonia Leak Detection Through X-Ray Fluorescence

    Science.gov (United States)

    Camp, Jordan; Barthelmy, Scott; Skinner, Gerry

    2013-01-01

    Ammonia leaks are a significant concern for the International Space Station (ISS). The ISS has external transport lines that direct liquid ammonia to radiator panels where the ammonia is cooled and then brought back to thermal control units. These transport lines and radiator panels are subject to stress from micrometeorites and temperature variations, and have developed small leaks. The ISS can accommodate these leaks at their present rate, but if the rate increased by a factor of ten, it could potentially deplete the ammonia supply and impact the proper functioning of the ISS thermal control system, causing a serious safety risk. A proposed ISS astrophysics instrument, the Lobster X-Ray Monitor, can be used to detect and localize ISS ammonia leaks. Based on the optical design of the eye of its namesake crustacean, the Lobster detector gives simultaneously large field of view and good position resolution. The leak detection principle is that the nitrogen in the leaking ammonia will be ionized by X-rays from the Sun, and then emit its own characteristic Xray signal. The Lobster instrument, nominally facing zenith for its astrophysics observations, can be periodically pointed towards the ISS radiator panels and some sections of the transport lines to detect and localize the characteristic X-rays from the ammonia leaks. Another possibility is to use the ISS robot arm to grab the Lobster instrument and scan it across the transport lines and radiator panels. In this case the leak detection can be made more sensitive by including a focused 100-microampere electron beam to stimulate X-ray emission from the leaking nitrogen. Laboratory studies have shown that either approach can be used to locate ammonia leaks at the level of 0.1 kg/day, a threshold rate of concern for the ISS. The Lobster instrument uses two main components: (1) a microchannel plate optic (also known as a Lobster optic) that focuses the X-rays and directs them to the focal plane, and (2) a CCD (charge

  17. Leak detection of thermal shield system in EAST cryostat%EAST装置大型低温杜瓦中内外冷屏系统的检漏

    Institute of Scientific and Technical Information of China (English)

    王雅婷; 王小明; 胡建生

    2015-01-01

    针对 EAST 装置大型低温杜瓦中内外冷屏系统存在的泄漏及对外真空室真空度的影响,采用氦质谱负压真空、正压真空及吸枪法相结合的方法,确定了多处泄漏点并分析了泄漏原因,通过修复使EAST外真空室低温运行时的压强﹤1×10-4Pa ,满足了EAST外真空室运行的需要。EAST内外冷屏系统的检漏方法和经验可以运用到大型、复杂的和具有狭小活动空间的真空系统检漏,尤其是对多管道、复杂材料的检漏具有一定的参考价值。%To solve the leakage of thermal shield system in EAST cryostat and its impact on pressure of cryogenic vacuum chamber, we adopted a combination method including vacuum leak detection, pressurized leak detection and sniffer leak detection. We found some leak parts and analyzed the cause of leakage. By mending the thermal shield system, the pressure of the cryogenic vacuum chamber is less than 1×10-4Pa at cryogenic state and meets the need of operation. The method and experience of EAST thermal shield system leak detection can be adopted to large-sized, complicated and narrow space vacuum system. Especially, the method and experience have a certain reference value in the leak detection of multi-pipeline and complicated material vacuum system.

  18. Development of a water leak detection system for LMFBR steam generators. Pt. 2; General planning of sensor arrangement for active acoustic method

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Kazuo; Kumagai, Hiromichi (Central Research Inst. of Electric Power Industry, Komae, Tokyo (Japan). Komae Research Lab.)

    1994-04-01

    Development of a water leak detection system with short response time and high sensitivity for LMFBR steam generators is required to prevent failure propagation and to maintain structural integrity of steam generators. A new type of leak detection method, active acoustic method, which observes gas bubbles accompanying the leak using sonic waves is being developed. In this study, some series of experiments are carried out to investigate; (1) attenuation of sonic wave in a typical SG structure, (2) suitable method to attach waveguides to the SG shell, and (3) possibility of reflex method. Furthermore, a reference sensor arrangement for active acoustic method is selected based on the experimental results as the basis of future studies. (author).

  19. Early tube leak detection system for steam boiler at KEV power plant

    Directory of Open Access Journals (Sweden)

    Ismail Firas B.

    2016-01-01

    Full Text Available Tube leakage in boilers has been a major contribution to trips which eventually leads to power plant shut downs. Training of network and developing artificial neural network (ANN models are essential in fault detection in critically large systems. This research focusses on the ANN modelling through training and validation of real data acquired from a sub-critical boiler unit. The artificial neural network (ANN was used to develop a compatible model and to evaluate the working properties and behaviour of boiler. The training and validation of real data has been applied using the feed-forward with back-propagation (BP. The right combination of number of neurons, number of hidden layers, training algorithms and training functions was run to achieve the best ANN model with lowest error. The ANN was trained and validated using real site data acquired from a coal fired power plant in Malaysia. The results showed that the Neural Network (NN with one hidden layers performed better than two hidden layer using feed-forward back-propagation network. The outcome from this study give us the best ANN model which eventually allows for early detection of boiler tube leakages, and forecast of a trip before the real shutdown. This will eventually reduce shutdowns in power plants.

  20. Hydrocarbon Leak Detection Sensor Project

    Data.gov (United States)

    National Aeronautics and Space Administration — FTT is proposing the development of a sensor to detect the presence of hydrocarbons in turbopump Inter-Propellant Seals (IPS). The purpose of the IPS is to prevent...

  1. Assuring asset integrity through improving the accuracy of leakage source identification of a permanently installed subsea leak detection system using artificial neural networks

    OpenAIRE

    Poungkrajorn, Tawan

    2015-01-01

    Environmental concerns and regulatory controls for oil and gas exploration and production activities have been increasing with the prospecting of deep-water fields and sensitive areas, such as the artic seas. To stop any incidents developing into critical events, subsea leak detection systems are required for a fast, cost-effective, and reasonable accurate method to not only detect the leakage substance (in this case methane), but also to identify its source and location. This thesis evaluate...

  2. Fiber Optic Sensors for Leak Detection and Condition Monitoring in Hydrogen Fuel Systems Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR Phase I proposal addresses the need for explosion proof, sensitive and reliable hydrogen sensors for NASA and commercial hydrogen fuel systems. It also...

  3. Research and development for the high-temperature helium-leak detection system (Joint research). Part 2. Development of temperature sensors using optical fibre for the HTTR

    Energy Technology Data Exchange (ETDEWEB)

    Sakaba, Nariaki; Nakazawa, Toshio; Kawasaki, Kozo [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment; Urakami, Masao; Saisyu, Sadanori [Japan Atomic Power Co., Tokyo (Japan)

    2003-03-01

    In the second stage of the research and development for a high-temperature helium-leak detection system, the temperature sensor using optical fibres was studied. The sensor detects the helium leakage by the temperature increase surrounded optical fibre with or without heat insulator. Moreover, the applicability of high temperature equipments as the HTTR system was studied. With the sensor we detected 5.0-20.0 cm{sup 3}/s helium leakages within 60 minutes. Also it was possible to detect earlier when the leakage level is at 20.0 cm {sup 3}/s. (author)

  4. Imaging spectrometer for fugitive gas leak detection

    Science.gov (United States)

    Hinnrichs, Michele

    1999-12-01

    Under contract to the U.S. Air Force and Navy, Pacific Advanced Technology has developed a very sensitive infrared imaging spectrometer that can perform remote imaging and spectro-radiometry. One of the most exciting applications for this technology is in the remote monitoring of smoke stack emissions and fugitive leaks. To date remote continuous emission monitoring (CEM) systems have not been approved by the EPA, however, they are under consideration. If the remote sensing technology is available with the sensitivity to monitor emission at the required levels and man portable it can reduce the cost and improve the reliability of performing such measurements. Pacific Advanced Technology (PAT) believes that it currently has this technology available to industry. This paper will present results from a field test where gas vapors during a refueling process were imaged and identified. In addition images of propane from a leaking stove will be presented. We at PAT have developed a real time image processing board that enhances the signal to noise ratio of low contrast gases and makes them easily viewable using the Image Multispectral Sensing (IMSS) imaging spectrometer. The IMSS imaging spectrometer is the size of a camcorder. Currently the data is stored in a Notebook computer thus allowing the system to be easily carried into power plants to look for fugitive leaks. In the future the IMSS will have an embedded processor and DSP and will be able to transfer data over an Ethernet link.

  5. Leak Detection in Offshore Pipelines of Conveying Fluid

    Institute of Scientific and Technical Information of China (English)

    李俊花; 崔莉

    2004-01-01

    Leakage from pipelines has caused serious environmental pollution and economic losses. Usually, leak detection can reduce the damage. The paper mainly discusses a hydraulic gradient-based leak detection method. The basic idea is outlined first, followed by a description of a laboratory experiment in a water pipeline. Several pressure curves are established based on different leak locations under the condition of a constant total flow rate. It is demonstrated that the leak of a large leak quantity can be detected reliably by the hydraulic gradient method.

  6. 340 Facility secondary containment and leak detection

    Energy Technology Data Exchange (ETDEWEB)

    Bendixsen, R.B.

    1995-01-31

    This document presents a preliminary safety evaluation for the 340 Facility Secondary Containment and Leak Containment system, Project W-302. Project W-302 will construct Building 340-C which has been designed to replace the current 340 Building and vault tank system for collection of liquid wastes from the Pacific Northwest Laboratory buildings in the 300 Area. This new nuclear facility is Hazard Category 3. The vault tank and related monitoring and control equipment are Safety Class 2 with the remainder of the structure, systems and components as Safety Class 3 or 4.

  7. Are Optical Gas Imaging Technologies Effective For Methane Leak Detection?

    Science.gov (United States)

    Ravikumar, Arvind P; Wang, Jingfan; Brandt, Adam R

    2017-01-03

    Concerns over mitigating methane leakage from the natural gas system have become ever more prominent in recent years. Recently, the U.S. Environmental Protection Agency proposed regulations requiring use of optical gas imaging (OGI) technologies to identify and repair leaks. In this work, we develop an open-source predictive model to accurately simulate the most common OGI technology, passive infrared (IR) imaging. The model accurately reproduces IR images of controlled methane release field experiments as well as reported minimum detection limits. We show that imaging distance is the most important parameter affecting IR detection effectiveness. In a simulated well-site, over 80% of emissions can be detected from an imaging distance of 10 m. Also, the presence of "superemitters" greatly enhance the effectiveness of IR leak detection. The minimum detectable limits of this technology can be used to selectively target "superemitters", thereby providing a method for approximate leak-rate quantification. In addition, model results show that imaging backdrop controls IR imaging effectiveness: land-based detection against sky or low-emissivity backgrounds have higher detection efficiency compared to aerial measurements. Finally, we show that minimum IR detection thresholds can be significantly lower for gas compositions that include a significant fraction nonmethane hydrocarbons.

  8. Performance comparison of TDR-based systems for permanent and diffused detection of water content and leaks

    Science.gov (United States)

    Cataldo, A.; De Benedetto, E.; Cannazza, G.; Huebner, C.; Trebbels, D.

    2017-01-01

    In this work, the performance of three time domain reflectometry (TDR) instruments (with different hardware architectures, specifications and costs) is comparatively assessed. The goal is to evaluate the performance of low-cost TDR instrumentation, in view of the development of a completely permanent TDR-based monitoring solution, wherein the costs of the instrument is so low, that it can be left on-site, even unguarded, and controlled remotely. Without losing generality, the applications considered for the comparative experiments are the TDR-based detection of leaks in underground pipes and, more in general, of soil water content variations. For this reason, both laboratory and in-the-field experiments are carried out by comparatively using three TDR instruments, in conjunction with wire-like sensing elements (SEs).

  9. Sample Delivery and Computer Control Systems for Detecting Leaks in the Main Engines of the Space Shuttle

    Science.gov (United States)

    Griffin, Timothy P.; Naylor, Guy R.; Hritz, Richard J.; Barrett, Carolyn A.

    1997-01-01

    The main engines of the Space Shuttle use hydrogen and oxygen as the fuel and oxidant. The explosive and fire hazards associated with these two components pose a serious danger to personnel and equipment. Therefore prior to use the main engines undergo extensive leak tests. Instead of using hazardous gases there tests utilize helium as the tracer element. This results in a need to monitor helium in the ppm level continuously for hours. The major challenge in developing such a low level gas monitor is the sample delivery system. This paper discuss a system developed to meet the requirements while also being mobile. Also shown is the calibration technique, stability, and accuracy results for the system.

  10. Fluid pipeline leak detection and location with miniature RF tags

    Energy Technology Data Exchange (ETDEWEB)

    McIntyre, Timothy J.

    2017-05-16

    Sensors locate troublesome leaks in pipes or conduits that carry a flowing medium. These sensors, through tailored physical and geometric properties, preferentially seek conduit leaks or breaches due to flow streaming. The sensors can be queried via transceivers outside the conduit or located and interrogated inside by submersible unmanned vehicle to identify and characterize the nature of a leak. The sensors can be functionalized with other capabilities for additional leak and pipeline characterization if needed. Sensors can be recovered from a conduit flow stream and reused for future leak detection activities.

  11. FUZZY INFERENCE BASED LEAK ESTIMATION IN WATER PIPELINES SYSTEM

    Directory of Open Access Journals (Sweden)

    N. Lavanya

    2015-01-01

    Full Text Available Pipeline networks are the most widely used mode for transporting fluids and gases around the world. Leakage in this pipeline causes harmful effects when the flowing fluid/gas is hazardous. Hence the detection of leak becomes essential to avoid/minimize such undesirable effects. This paper presents the leak detection by spectral analysis methods in a laboratory pipeline system. Transient in the pressure signal in the pipeline is created by opening and closing the exit valve. These pressure variations are captured and power spectrum is obtained by using Fast Fourier Transform (FFT method and Filter Diagonalization Method (FDM. The leaks at various positions are simulated and located using these methods and the results are compared. In order to determine the quantity of leak a 2 × 1 fuzzy inference system is created using the upstream and downstream pressure as input and the leak size as the output. Thus a complete leak detection, localization and quantification are done by using only the pressure variations in the pipeline.

  12. 241-AY-102 Leak Detection Pit Drain Line Inspection Report

    Energy Technology Data Exchange (ETDEWEB)

    Boomer, Kayle D. [Washington River Protection Solutions, LLC (United States); Engeman, Jason K. [Washington River Protection Solutions, LLC (United States); Gunter, Jason R. [Washington River Protection Solutions, LLC (United States); Joslyn, Cameron C. [Washington River Protection Solutions, LLC (United States); Vazquez, Brandon J. [Washington River Protection Solutions, LLC (United States); Venetz, Theodore J. [Washington River Protection Solutions, LLC (United States); Garfield, John S. [AEM Consulting (United States)

    2014-01-20

    This document provides a description of the design components, operational approach, and results from the Tank AY-102 leak detection pit drain piping visual inspection. To perform this inspection a custom robotic crawler with a deployment device was designed, built, and operated by IHI Southwest Technologies, Inc. for WRPS to inspect the 6-inch leak detection pit drain line.

  13. Active acoustic leak detection for LMFBR steam generators. Pt. 7. Potential for small leak detection

    Energy Technology Data Exchange (ETDEWEB)

    Kumagai, Hiromichi; Yoshida, Kazuo [Central Research Inst. of Electric Power Industry, Komae, Tokyo (Japan). Komae Research Lab.

    1998-05-01

    In order to prevent the expansion of tube damage and to maintain structural integrity in the steam generators (SGs) of fast breeder reactors (FBR), it is necessary to detect precisely and immediately the leakage of water from heat transfer tubes. Therefore, an active acoustic method, which detects the sound attenuation due to bubbles generated in the sodium-water reactions, is being developed. Previous studies have revealed that the active acoustic method can detect bubbles of 10 l/s (equivalence water leak rate about 10 g/s) within 10 seconds in practical steam generators. In order to prevent the expansion of damage to neighboring tubes, however, it is necessary to detect smaller leakage of water from heat transfer tubes. In this study, in order to evaluate the detection sensitivity of the active method, the signal processing methods for emitter and receiver sound and the detection method for leakage within 1 g/s are investigated experimentally, using an SG full-sector model that simulates the actual SGs. A typical result shows that detection of 0.4 l/s air bubbles (equivalent water leak rate about 0.4 g/s) takes about 80 seconds, which is shorter than the propagation time of damage to neighboring tubes. (author)

  14. Electrical detection of liquid lithium leaks from pipe jointsa)

    Science.gov (United States)

    Schwartz, J. A.; Jaworski, M. A.; Mehl, J.; Kaita, R.; Mozulay, R.

    2014-11-01

    A test stand for flowing liquid lithium is under construction at Princeton Plasma Physics Laboratory. As liquid lithium reacts with atmospheric gases and water, an electrical interlock system for detecting leaks and safely shutting down the apparatus has been constructed. A defense in depth strategy is taken to minimize the risk and impact of potential leaks. Each demountable joint is diagnosed with a cylindrical copper shell electrically isolated from the loop. By monitoring the electrical resistance between the pipe and the copper shell, a leak of (conductive) liquid lithium can be detected. Any resistance of less than 2 kΩ trips a relay, shutting off power to the heaters and pump. The system has been successfully tested with liquid gallium as a surrogate liquid metal. The circuit features an extensible number of channels to allow for future expansion of the loop. To ease diagnosis of faults, the status of each channel is shown with an analog front panel LED, and monitored and logged digitally by LabVIEW.

  15. Active Stand-off Detection of Gas Leaks Using a Short Range Hard-target Backscatter Differential Optical Absorption System Based on a Quantum Cascade Laser Transmitter

    Science.gov (United States)

    Diaz, Adrian; Thomas, Benjamin; Castillo, Paulo; Gross, Barry; Moshary, Fred

    2016-06-01

    Fugitive gas emissions from agricultural or industrial plants and gas pipelines are an important environmental concern as they can contribute to the global increase of greenhouse gas concentration. Moreover, they are also a security and safety concern because of possible risk of fire/explosion or toxicity. This study presents gas concentration measurements using a quantum cascade laser open path system (QCLOPS). The system retrieves the pathaveraged concentration of N2O and CH4 by collecting the backscattered light from a scattering target. The gas concentration measurements have a high temporal resolution (68 ms) and are achieved at sufficient range (up to 40 m, ~ 130 feet) with a detection limit of 2.6 ppm CH4 and 0.4 ppm for N2O. Given these characteristics, this system is promising for mobile/multidirectional remote detection and evaluation of gas leaks. The instrument is monostatic with a tunable QCL emitting at ~ 7.7 μm wavelength range. The backscattered radiation is collected by a Newtonian telescope and focused on an infrared light detector. Puffs of N2O and CH4 are released along the optical path to simulate a gas leak. The measured absorption spectrum is obtained using the thermal intra-pulse frequency chirped DFB QCL and is analyzed to obtain path averaged gas concentrations.

  16. Acoustic valve leak detection: Initial program development, implementation & experience

    Energy Technology Data Exchange (ETDEWEB)

    Wicker, G.L. [Baltimore Gas and Electric Company, Baltimore, MD (United States)

    1996-07-01

    Acoustic valve leak detection is one of the many test techniques employed in modern power plants with active predictive maintenance programs. In 1994, a valve leak detection program was implemented within Baltimore Gas and Electric`s Fossil Energy Division. Within two years, the program resulted in energy savings in excess of one million dollars. The leak detection program has become an essential technology that has reduced plant heat rate losses, prevented unnecessary valve maintenance and increased plant awareness of potential losses. This paper describes program development, implementation and test methodology of Baltimore Gas and Electric`s acoustic leak detection program. Key topics include equipment description, program measurements, methodology and leak identification methods. The paper also will include discussion on the practical approach of equipment selection and program philosophies.

  17. Methane Leaks from Natural Gas Systems Follow Extreme Distributions.

    Science.gov (United States)

    Brandt, Adam R; Heath, Garvin A; Cooley, Daniel

    2016-11-15

    Future energy systems may rely on natural gas as a low-cost fuel to support variable renewable power. However, leaking natural gas causes climate damage because methane (CH4) has a high global warming potential. In this study, we use extreme-value theory to explore the distribution of natural gas leak sizes. By analyzing ∼15 000 measurements from 18 prior studies, we show that all available natural gas leakage data sets are statistically heavy-tailed, and that gas leaks are more extremely distributed than other natural and social phenomena. A unifying result is that the largest 5% of leaks typically contribute over 50% of the total leakage volume. While prior studies used log-normal model distributions, we show that log-normal functions poorly represent tail behavior. Our results suggest that published uncertainty ranges of CH4 emissions are too narrow, and that larger sample sizes are required in future studies to achieve targeted confidence intervals. Additionally, we find that cross-study aggregation of data sets to increase sample size is not recommended due to apparent deviation between sampled populations. Understanding the nature of leak distributions can improve emission estimates, better illustrate their uncertainty, allow prioritization of source categories, and improve sampling design. Also, these data can be used for more effective design of leak detection technologies.

  18. Ultra high vacuum pumping system and high sensitivity helium leak detector

    Science.gov (United States)

    Myneni, Ganapati Rao

    1997-01-01

    An improved helium leak detection method and apparatus are disclosed which increase the leak detection sensitivity to 10.sup.-13 atm cc s.sup.-1. The leak detection sensitivity is improved over conventional leak detectors by completely eliminating the use of o-rings, equipping the system with oil-free pumping systems, and by introducing measured flows of nitrogen at the entrances of both the turbo pump and backing pump to keep the system free of helium background. The addition of dry nitrogen flows to the system reduces backstreaming of atmospheric helium through the pumping system as a result of the limited compression ratios of the pumps for helium.

  19. Passive Leak Detection Using Commercial Hydrogen Colorimetric Indicator

    Energy Technology Data Exchange (ETDEWEB)

    Hartmann, Kevin [National Renewable Energy Lab. (NREL), Golden, CO (United States); Buttner, William [National Renewable Energy Lab. (NREL), Golden, CO (United States); Burgess, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States); Rivkin, Carl [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-09-01

    Element One, Inc. (www.elem.com), a small business with in Boulder, CO, has been developing hydrogen detection technology based upon a highly selective colorimetric indicator. In its native state, the indicator pigment is a pale gray color, but becomes black upon exposure to hydrogen. The colorimetric change can be readily observed by the naked eye without the need for supplemental electronics or other hardware. Recently, the colorimetric indicator was integrated into a pliable, self-adhesive tape that can readily wrap around pneumatic fittings to serve as a hydrogen leak detector. A prototype version of the Element One indicator tape was tested within an NREL hydrogen system and successfully identified the unexpected presence of a small leak; a summary document for this case study is presented in Appendix 1. The tape was subsequently configured into 10-foot rolls as a product prototype that has just recently been commercialized and marketed under the tradename DetecTape(R). Figure 1 shows the commercial version of DetecTape along with an indicator sample in its native state and one that had been exposed to hydrogen. DetecTape is a self-adhesive silicone-based tape impregnated with a proprietary hydrogen-sensitive indicator based on transition metal oxides. A length of the tape can be cut from the roll and stretched by a factor of two or three times around a fitting. Due to the self-adhesive property of the tape, this provides a tight seal around the fitting. The seal is not hermetic, and is not intended to prevent the release of a leaking gas. However, a portion of the hydrogen leaking from a wrapped fitting will pass through the tape and react with the active indicator impregnated within the tape, thereby inducing blackening.

  20. Detecting gas leaks by ultrasonic emission

    DEFF Research Database (Denmark)

    Rasmussen, Karsten Bo; Henriksen, Eigil

    1997-01-01

    The emission of noise in the frequency range 10 kHz to 25.6 kHz from an experimental gas leak in a flanged joint has been experimentally investigated. The overall conclusion is that the emitted noise is almost frequency independent in level within the considered frequency range.A small PC program...

  1. Leak detection utilizing analog binaural (VLSI) techniques

    Science.gov (United States)

    Hartley, Frank T. (Inventor)

    1995-01-01

    A detection method and system utilizing silicon models of the traveling wave structure of the human cochlea to spatially and temporally locate a specific sound source in the presence of high noise pandemonium. The detection system combines two-dimensional stereausis representations, which are output by at least three VLSI binaural hearing chips, to generate a three-dimensional stereausis representation including both binaural and spectral information which is then used to locate the sound source.

  2. Creation of an Exergetic Based Leak Detection and Diagnosis Methodology for Automotive Carbon Dioxide Air Conditioning Systems

    Directory of Open Access Journals (Sweden)

    M. B. Bailey

    2010-03-01

    Full Text Available

    Carbon dioxide automotive air conditioning (AC systems have been under development for over a decade. Although the AC system construction is important, a reliable refrigerant leakage detection system is also vital. A detailed thermodynamic simulation model and fault detection and diagnosis (FDD system, with proposed validation plans, has been developed at Rochester Institute of Technology. A discussion of simulation models that have been developed for various compressors and heat exchangers is presented; they are compared to actual AC systems to develop a realistic experimental setup. Assumptions from previous work are examined and improved.

    • Portions of this paper were previously published in the ECOS'05 and ECOS'07 conference proceedings.

  3. Modeling leaks from liquid hydrogen storage systems.

    Energy Technology Data Exchange (ETDEWEB)

    Winters, William Stanley, Jr.

    2009-01-01

    This report documents a series of models for describing intended and unintended discharges from liquid hydrogen storage systems. Typically these systems store hydrogen in the saturated state at approximately five to ten atmospheres. Some of models discussed here are equilibrium-based models that make use of the NIST thermodynamic models to specify the states of multiphase hydrogen and air-hydrogen mixtures. Two types of discharges are considered: slow leaks where hydrogen enters the ambient at atmospheric pressure and fast leaks where the hydrogen flow is usually choked and expands into the ambient through an underexpanded jet. In order to avoid the complexities of supersonic flow, a single Mach disk model is proposed for fast leaks that are choked. The velocity and state of hydrogen downstream of the Mach disk leads to a more tractable subsonic boundary condition. However, the hydrogen temperature exiting all leaks (fast or slow, from saturated liquid or saturated vapor) is approximately 20.4 K. At these temperatures, any entrained air would likely condense or even freeze leading to an air-hydrogen mixture that cannot be characterized by the REFPROP subroutines. For this reason a plug flow entrainment model is proposed to treat a short zone of initial entrainment and heating. The model predicts the quantity of entrained air required to bring the air-hydrogen mixture to a temperature of approximately 65 K at one atmosphere. At this temperature the mixture can be treated as a mixture of ideal gases and is much more amenable to modeling with Gaussian entrainment models and CFD codes. A Gaussian entrainment model is formulated to predict the trajectory and properties of a cold hydrogen jet leaking into ambient air. The model shows that similarity between two jets depends on the densimetric Froude number, density ratio and initial hydrogen concentration.

  4. Color Changing Material for Hydrogen Leak Detection

    Science.gov (United States)

    Victor, Megan E.

    2014-01-01

    Kennedy Space Center scientists developed a hydrogen leak sensor utilizing a combination of chemochromic pigment and polymer that can be molded or fiber spun into rigid or flexible shapes such as tape. The sensor turns a dark color when exposed to hydrogen gas. This sensor has proven to be very effective for pinpointing the exact location of leaks in hydrogen gas lines and fittings at launch pads. Kennedy Space Center exclusively licensed this technology to the University of Central Florida (UCF), who also holds patents that are complimentary to KSC's. UCF has bundled the patents and exclusively licensed the portfolio to HySense Technology LLC, a startup company founded by a UCF professor who supports the UCF Florida Solar Energy Center (FSEC). HySense has fully developed its product (known as Intellipigment"TM"), and currently has five commercial customers. The company recently won the $100,000 first-place award at the CAT5 innovation competition at the Innovation Concourse of the Southeast: Safety & Manufacturing event in Orlando, FL. Commercial production and sales of this technology by HySense Technology will make this leak sensor widely available for use by NASA, DoD, and industries that utilize hydrogen gas.

  5. ALIBABA, an assistance system for the detection of confinement leaks in a PWR reactor; ALIBABA, un systeme d`aide a la detection des voies de fuites du confinement sur un reacteur a eau sous pression

    Energy Technology Data Exchange (ETDEWEB)

    Bedier, P.O.; Libmann, M. [CEA Centre d`Etudes de Saclay, 91 - Gif-sur-Yvette (France). Dept. de Mecanique et de Technologie

    1995-12-31

    The objective of the Crisis Technical Center (CTC) of the French Institute for Nuclear Protection and Safety (IPSN) is to estimates the consequences of a given nuclear accident on the populations and the environment. ALIBABA is a data processing tool available at the CTC and devoted to the detection of confinement leaks in 900 MWe PWR reactors using the activity values measured by the captors of the installation. The heart of this expert system is a structural and functional representation of the different components directly involved in the leak detection (isolating valves, ventilation systems, electric boards etc..). This tool can manage the availability of each component to make qualitative and quantitative balance-sheets. This paper presents the ALIBABA software, an industrial prototype realized with the SPIRAL knowledge base systems generator at the CEA Reactor Studies and Applied Mathematics Service (SERMA) and commercialized by CRIL-Ingenierie Society. It describes the techniques used for the modeling of PWR systems and for the visualization of the survey. The functionality of the man-machine interface is discussed and the means used for the validation of the software are summarized. (J.S.). 6 refs.

  6. Space Shuttle Main Engine Propellant Path Leak Detection Using Sequential Image Processing

    Science.gov (United States)

    Smith, L. Montgomery; Malone, Jo Anne; Crawford, Roger A.

    1995-01-01

    Initial research in this study using theoretical radiation transport models established that the occurrence of a leak is accompanies by a sudden but sustained change in intensity in a given region of an image. In this phase, temporal processing of video images on a frame-by-frame basis was used to detect leaks within a given field of view. The leak detection algorithm developed in this study consists of a digital highpass filter cascaded with a moving average filter. The absolute value of the resulting discrete sequence is then taken and compared to a threshold value to produce the binary leak/no leak decision at each point in the image. Alternatively, averaging over the full frame of the output image produces a single time-varying mean value estimate that is indicative of the intensity and extent of a leak. Laboratory experiments were conducted in which artificially created leaks on a simulated SSME background were produced and recorded from a visible wavelength video camera. This data was processed frame-by-frame over the time interval of interest using an image processor implementation of the leak detection algorithm. In addition, a 20 second video sequence of an actual SSME failure was analyzed using this technique. The resulting output image sequences and plots of the full frame mean value versus time verify the effectiveness of the system.

  7. Design of wide- band gas leak infrared imaging detection system%宽波段气体泄漏红外成像检测系统设计

    Institute of Scientific and Technical Information of China (English)

    李家琨; 顿雄; 金明磊; 金伟其; 王霞; 夏润秋

    2014-01-01

    有毒有害气体的泄漏不仅污染环境,而且威胁人民生命财产安全,世界各国都非常重视快速有效的气体泄漏检测技术的研究和仪器开发。针对这一问题,提出了宽波段气体泄漏红外成像检测系统设计方案,主要包括宽波段红外光学镜头尧子波段滤光片及切换装置尧宽波段非制冷焦平面探测器尧视频处理及系统控制电路等组成部分,充分利用非制冷探测器的无光谱选择特性,结合热图像非均匀性校正和数字细节增强处理算法,实现了对不同种类气体泄漏的高灵敏度检测,提供了适合人眼判断的气体泄漏视频图像显示结果。整个系统具有可检测气体种类多尧检测范围大速度快尧气体泄漏痕迹明显增强尧系统便携性突出尧成本相对较低等特点。%The leakage of toxic or hazardous gases not only pollutes the environment, but also threatens people’s lives and property safety. Many countries attach great importance to the rapid and effective gas leak detection technology and instrument development. To address this issue, a wide- band gas leak IR imaging detection system design was proposed, mainly including wide- band IR optical lens, the sub- band filters and switching device, wide- band Uncooled Focal Plane Array (UFPA) detector, video processing and system control circuit, which takes full advantage of the spectrally non- selective characteristic of the uncooled focal plane array detector. The system can sensitively detect and visualize a considerable number of different kinds of gases, which are not visible to the naked eyes, by using the IR image non-uniformity correction technology and Digital Detail Enhancement (DDE) technology. The resulting gas leak video easy to be observed for the human eye was provided. Many advantages are commendable, such as scanning a wide range simultaneously, locating the leaking source quickly, visualizing the gas plume intuitively, and

  8. Leaks in gas pipelines. Leak detection with the aid of GIS and GPS; Leckstellen in Gasrohrnetzen. Aufspueren mit Unterstuetzung durch GIS und GPS

    Energy Technology Data Exchange (ETDEWEB)

    Huber, Detlef; Berteld, Michael [Industrielle Werke Basel (Switzerland)

    2009-12-15

    The GPS technology has made gas leak detection more efficient. By linking it with the documentation of the Geographic Information System (GIS), gas grid monitoring, long-term planning and also maintenance can be optimized considerably. After successful testing, Industrielle Werke Basel (IWB) introduced the system for their whole gas grid. Apart from cost savings, there was also a significant quality improvement in gas leak detection. (orig.)

  9. Helium Mass Spectrometer Leak Detection: A Method to Quantify Total Measurement Uncertainty

    Science.gov (United States)

    Mather, Janice L.; Taylor, Shawn C.

    2015-01-01

    In applications where leak rates of components or systems are evaluated against a leak rate requirement, the uncertainty of the measured leak rate must be included in the reported result. However, in the helium mass spectrometer leak detection method, the sensitivity, or resolution, of the instrument is often the only component of the total measurement uncertainty noted when reporting results. To address this shortfall, a measurement uncertainty analysis method was developed that includes the leak detector unit's resolution, repeatability, hysteresis, and drift, along with the uncertainty associated with the calibration standard. In a step-wise process, the method identifies the bias and precision components of the calibration standard, the measurement correction factor (K-factor), and the leak detector unit. Together these individual contributions to error are combined and the total measurement uncertainty is determined using the root-sum-square method. It was found that the precision component contributes more to the total uncertainty than the bias component, but the bias component is not insignificant. For helium mass spectrometer leak rate tests where unit sensitivity alone is not enough, a thorough evaluation of the measurement uncertainty such as the one presented herein should be performed and reported along with the leak rate value.

  10. ANALYSIS OF FIRST TRANSIENT PRESSURE OSCILLATION FOR LEAK DETECTION IN A SINGLE PIPELINE

    Institute of Scientific and Technical Information of China (English)

    GUO Xin-lei; YANG Kai-lin; LI Fu-tian; WANG Tao; FU hui

    2012-01-01

    The leak detection is of great importance in the reliable operation and management of a pipeline system.Recently,attention is shifted to the use of the time domain or frequency domain methods based on the transient analysis.These methods sometimes require accurate pressure signals obtained during the transient period or by creating ideal conditions in testing.This paper proposes a method that does not require transient simulations over the whole or an extended period of time,but uses the first transient pressure oscillation to detect leaks.The method considers the propagation of the pressure oscillation wave created from a tast valve closure and the reflected damp wave from the leak.A leak in the pipe gives rise to reflected waves which in turn create discontinuities in the observed signal at the measurement section.The timing of the reflected damp wave and the magnitude represent the location and the size of the leak,respectively.An analytical expression is derived based on the Method Of Characteristic (MOC) for the relationship between the leakage and the reflected magnitude.The leak detection procedure based on the method is also given.Then the reliability of the method is tested on numerically simulated pressure signals and experimental pressure signals with calibrated leak parameters,and the results indicate a successful application and the promising features of the method.

  11. AIRBORNE, OPTICAL REMOTE SENSNG OF METHANE AND ETHANE FOR NATURAL GAS PIPELINE LEAK DETECTION

    Energy Technology Data Exchange (ETDEWEB)

    Jerry Myers

    2005-04-15

    Ophir Corporation was awarded a contract by the U. S. Department of Energy, National Energy Technology Laboratory under the Project Title ''Airborne, Optical Remote Sensing of Methane and Ethane for Natural Gas Pipeline Leak Detection'' on October 14, 2002. The scope of the work involved designing and developing an airborne, optical remote sensor capable of sensing methane and, if possible, ethane for the detection of natural gas pipeline leaks. Flight testing using a custom dual wavelength, high power fiber amplifier was initiated in February 2005. Ophir successfully demonstrated the airborne system, showing that it was capable of discerning small amounts of methane from a simulated pipeline leak. Leak rates as low as 150 standard cubic feet per hour (scf/h) were detected by the airborne sensor.

  12. Active acoustic leak detection for LMFBR steam generators. Pt. 6. Applicability to practical steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Kazuo; Kumagai, Hiromichi; Kinoshita, Izumi [Central Research Inst. of Electric Power Industry, Komae, Tokyo (Japan). Komae Research Lab.

    1998-03-01

    It is necessary to develop a reliable water leak detection system for steam generators of liquid metal reactors in order to prevent the expansion of damage and to maintain the structural integrity of the steam generators. The concept of the active acoustic method is to detect the change of the ultrasonic field due to the hydrogen gas bubbles generated by a sodium-water reaction. This method has the potential for improved detection performance compared with conventional passive methods, from the viewpoint of sensitivity, response time and tolerance against the background noise. A feasibility study of the active acoustic leak detection system is being carried out. This report predicts the performance of the active acoustic method in the practical steam generators from the results of the large scale in-water experiments. The results shows that the active acoustic system can detect a 10 g/s leak within a few seconds in large-scale steam generators. (author)

  13. Detection and Prevention of Sensitive Data From Data Leak Using Shingling and Rabin Filter

    Directory of Open Access Journals (Sweden)

    Sushma Vishwanath Gaikwad

    2016-10-01

    Full Text Available Data leak is a major problem in all the organization of any land. A deliberate risk to institution and private security is the disclosure of secure data in transmission and storage. To check content for exposed sensitive data is the main aim for exposed sensitive data. There are large numbers of data-leak cases but human flaws are one of the main reasons of data leak. This paper proposed a data-leak detection model for preventing accidental and intentional data leak in network. If someone succeed to steal some kind of data and send that data to outsider then data owner has obtain to use two methods to find out guilty employee or leaker. This work suggests use of shingling and rabin filter system performs Data Leak Detection (DLD and Prevention task. The results show that this approach can be effectively implemented in various organizations; however rigorous testing on various data division of such methods will be required to implement the same in sector of importance like defence and other even in large establishment. Keywords—  Information security; Data leak; network security; privacy.

  14. The CMEKF Method for Sub-Sea Pipeline Monitoring and Leak Detection

    Institute of Scientific and Technical Information of China (English)

    白莉; 岳前进; 崔莉; 李洪升; 金兆玉; 王庆国

    2004-01-01

    A practical approach is discussed for sub-sea pipeline monitoring and leak detection based on the real time transient model (RTTM). The characteristic method (CM) of transient simulation is coupled with the Extended Kalman Filter(EKF) to estimate the system state where the only observed data are inlet and outlet flow rate and pressure. Because EKF has a time variant track under the non-stationary stochastic process with additive Gaussian noise, the high sensitivity of RTTM to non-stationary operating condition is reduced. A leak location recursion estimation formula is presented based on the real time observed data. The results of 27 groups of test data indicate that the procedure presented is sensitive to a wide range of detectable leak sizes ( 1.5% ~ 57% of inlet flow rate) and has a low average relative error of leak location(<5%).

  15. Leaks in the internal water supply piping systems

    Directory of Open Access Journals (Sweden)

    Orlov Evgeniy Vladimirovich

    2015-03-01

    Full Text Available Great water losses in the internal plumbing of a building lead to the waste of money for a fence, purification and supply of water volumes in excess. This does not support the concept of water conservation and resource saving lying today in the basis of any building’s construction having plumbing. Leakage means unplanned of water losses systems in domestic water supply systems (hot or cold as a result of impaired integrity, complicating the operation of a system and leading to high costs of repair and equipment restoration. A large number of leaks occur in old buildings, where the regulatory service life of pipelines has come to an end, and the scheduled repair for some reason has not been conducted. Steel pipelines are used in the systems without any protection from corrosion and they get out of order. Leakages in new houses are also not uncommon. They usually occur as a result of low-quality adjustment of the system by workers. It also important to note the absence of certain skills of plumbers, who don’t conduct the inspections of in-house systems in time. Sometimes also the residents themselves forget to keep their pipeline systems and water fittings in their apartment in good condition. Plumbers are not systematically invited for preventive examinations to detect possible leaks in the domestic plumbing. The amount of unproductive losses increases while simultaneous use of valve tenants, and at the increase of the number of residents in the building. Water leaks in the system depend on the amount of water system piping damages, and damages of other elements, for example, water valves, connections, etc. The pressure in the leak area also plays an important role.

  16. Management of Leaks in Hydrogen Production, Delivery, and Storage Systems

    Energy Technology Data Exchange (ETDEWEB)

    Rawls, G

    2006-04-27

    A systematic approach to manage hydrogen leakage from components is presented. Methods to evaluate the quantity of hydrogen leakage and permeation from a system are provided by calculation and testing sensitivities. The following technology components of a leak management program are described: (1) Methods to evaluate hydrogen gas loss through leaks; (2) Methods to calculate opening areas of crack like defects; (3) Permeation of hydrogen through metallic piping; (4) Code requirements for acceptable flammability limits; (5) Methods to detect flammable gas; (6) Requirements for adequate ventilation in the vicinity of the hydrogen system; (7) Methods to calculate dilution air requirements for flammable gas mixtures; and (8) Concepts for reduced leakage component selection and permeation barriers.

  17. Real time detection of leaks in non-compressible fluid flow systems: a time series approach; Deteccao em tempo real de vazamentos em redes de escoamento para fluidos incompressiveis: uma abordagem em series temporais

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Cesar Augusto Fernandes de [Universidade Federal, Rio de Janeiro, RJ (Brazil). Escola de Quimica. Lab. SDV - Dutos]. E-mail: jlm@eq.ufrj.br

    2002-06-01

    Algorithms were developed for real time detection, estimation and location of leaks in flow systems operating with non-compressible fluids. Process inputs and outputs are assumed to be available by means of field sensing, treated through historical time series reconciliation and storage. The process presented herein was built as a pseudo stationary system for process data generation at the selected variables: nodal pressures, flow rates in pipes and input and output nodes. The procedure consists in generating data series during the occurrence of programmed events and use them during the training of ARX/ARMAX structure MIMO predictors, with constant update. A sudden leak is detected by a statistically significant instant deviation between a group of predictions and the measures of the process associated with the predictors' answers. Once the event is identified, the next step is to locate and estimate its size using another group of predictors trained through simulated process data of known leak events. These predictors use leak parameters (i.e., its location and orifice diameter) as additional inputs so that estimation can be performed in order to predict real answers to the process that are being deviated from the original predictions monitored during the manifestation of the event. (author)

  18. Methane Leak Detection and Emissions Quantification with UAVs

    Science.gov (United States)

    Barchyn, T.; Fox, T. A.; Hugenholtz, C.

    2016-12-01

    Robust leak detection and emissions quantification algorithms are required to accurately monitor greenhouse gas emissions. Unmanned aerial vehicles (UAVs, `drones') could both reduce the cost and increase the accuracy of monitoring programs. However, aspects of the platform create unique challenges. UAVs typically collect large volumes of data that are close to source (due to limited range) and often lower quality (due to weight restrictions on sensors). Here we discuss algorithm development for (i) finding sources of unknown position (`leak detection') and (ii) quantifying emissions from a source of known position. We use data from a simulated leak and field study in Alberta, Canada. First, we detail a method for localizing a leak of unknown spatial location using iterative fits against a forward Gaussian plume model. We explore sources of uncertainty, both inherent to the method and operational. Results suggest this method is primarily constrained by accurate wind direction data, distance downwind from source, and the non-Gaussian shape of close range plumes. Second, we examine sources of uncertainty in quantifying emissions with the mass balance method. Results suggest precision is constrained by flux plane interpolation errors and time offsets between spatially adjacent measurements. Drones can provide data closer to the ground than piloted aircraft, but large portions of the plume are still unquantified. Together, we find that despite larger volumes of data, working with close range plumes as measured with UAVs is inherently difficult. We describe future efforts to mitigate these challenges and work towards more robust benchmarking for application in industrial and regulatory settings.

  19. Leak Detection and H2 Sensor Development for Hydrogen Applications

    Energy Technology Data Exchange (ETDEWEB)

    Brosha, Eric L. [Los Alamos National Laboratory

    2012-07-10

    The objectives of this report are: (1) Develop a low cost, low power, durable, and reliable hydrogen safety sensor for a wide range of vehicle and infrastructure applications; (2) Continually advance test prototypes guided by materials selection, sensor design, electrochemical R&D investigation, fabrication, and rigorous life testing; (3) Disseminate packaged sensor prototypes and control systems to DOE Laboratories and commercial parties interested in testing and fielding advanced prototypes for cross-validation; (4) Evaluate manufacturing approaches for commercialization; and (5) Engage an industrial partner and execute technology transfer. Recent developments in the search for sustainable and renewable energy coupled with the advancements in fuel cell powered vehicles (FCVs) have augmented the demand for hydrogen safety sensors. There are several sensor technologies that have been developed to detect hydrogen, including deployed systems to detect leaks in manned space systems and hydrogen safety sensors for laboratory and industrial usage. Among the several sensing methods electrochemical devices that utilize high temperature-based ceramic electrolytes are largely unaffected by changes in humidity and are more resilient to electrode or electrolyte poisoning. The desired sensing technique should meet a detection threshold of 1% (10,000 ppm) H{sub 2} and response time of {approx_equal}1 min, which is a target for infrastructure and vehicular uses. Further, a review of electrochemical hydrogen sensors by Korotcenkov et.al and the report by Glass et.al suggest the need for inexpensive, low power, and compact sensors with long-term stability, minimal cross-sensitivity, and fast response. This view has been largely validated and supported by the fuel cell and hydrogen infrastructure industries by the NREL/DOE Hydrogen Sensor Workshop held on June 8, 2011. Many of the issues preventing widespread adoption of best-available hydrogen sensing technologies available today

  20. Leak detection, monitoring, and mitigation technology trade study update

    Energy Technology Data Exchange (ETDEWEB)

    HERTZEL, J.S.

    1998-11-10

    This document is a revision and update to the initial report that describes various leak detection, monitoring, and mitigation (LDMM) technologies that can be used to support the retrieval of waste from the single-shell tanks (SST) at the Hanford Site. This revision focuses on the improvements in the technical performance of previously identified and useful technologies, and it introduces new technologies that might prove to be useful.

  1. PRACTICAL IMPLICATIONS OF USING INDUCED TRANSIENTS FOR LEAK DETECTION

    Directory of Open Access Journals (Sweden)

    Marko V. Ivetic

    2007-01-01

    Full Text Available This paper deals with practical problems of leak detection by methods based on hydraulic transient analysis. Controlled and safe transients can be generated and the response of the network, with the relevant information, can be monitored and analysed. Information about leaks, contained in the monitored pressure signal, cannot be easily retrieved, due to reflections, noise etc. On the basis of numerical experiments on a simple network, merits and limitations of several methods for signal analysis (time domain analysis, spectral density function and wavelet transform have been examined. Certain amount of information can be extracted from the time history of the pressure signal, assuming the first reflection of the pressure wave is captured with very high time resolution and accuracy. Only relatively large leaks can be detected using this methodology. As a way to increase the sensitivity of this method it is suggested that transforms in frequency domain and, especially, wavelet transforms, are used. The most promising method for leakage location and quantification seems to be based on wavelet analysis.

  2. PRACTICAL IMPLICATIONS OF USING INDUCED TRANSIENTS FOR LEAK DETECTION

    Directory of Open Access Journals (Sweden)

    Marko V. Ivetic

    2007-06-01

    Full Text Available This paper deals with practical problems of leak detection by methods based on hydraulic transient analysis. Controlled and safe transients can be generated and the response of the network, with the relevant information, can be monitored and analysed. Information about leaks, contained in the monitored pressure signal, cannot be easily retrieved, due to reflections, noise etc. On the basis of numerical experiments on a simple network, merits and limitations of several methods for signal analysis (time domain analysis, spectral density function and wavelet transform have been examined. Certain amount of information can be extracted from the time history of the pressure signal, assuming the first reflection of the pressure wave is captured with very high time resolution and accuracy. Only relatively large leaks can be detected using this methodology. As a way to increase the sensitivity of this method it is suggested that transforms in frequency domain and, especially, wavelet transforms, are used. The most promising method for leakage location and quantification seems to be based on wavelet analysis.

  3. EXTENDED PERFORMANCE HANDHELD AND MOBILE SENSORS FOR REMOTE DETECTION OF NATURAL GAS LEAKS

    Energy Technology Data Exchange (ETDEWEB)

    Michael B. Frish; B. David Green; Richard T. Wainner; Francesca Scire-Scappuzzo; Paul Cataldi; Matthew C. Laderer

    2005-05-01

    This report summarizes work performed by Physical Sciences Inc. (PSI) to advance the state-of-the-art of surveying for leaks of natural gas from transmission and distribution pipelines. The principal project goal was to develop means of deploying on an automotive platform an improved version of the handheld laser-based standoff natural gas leak detector previously developed by PSI and known as the Remote Methane Leak Detector or RMLD. A laser beam which interrogates the air for methane is projected from a spinning turret mounted upon a van. As the van travels forward, the laser beam scans an arc to the front and sides of the van so as to survey across streets and to building walls from a moving vehicle. When excess methane is detected within the arc, an alarm is activated. In this project, we built and tested a prototype Mobile RMLD (MRMLD) intended to provide lateral coverage of 10 m and one lateral scan for every meter of forward motion at forward speeds up to 10 m/s. Using advanced detection algorithms developed as part of this project, the early prototype MRMLD, installed on the back of a truck, readily detected simulated gas leaks of 50 liters per hour. As a supplement to the originally planned project, PSI also participated in a DoE demonstration of several gas leak detection systems at the Rocky Mountain Oilfield Testing Center (RMOTC) during September 2004. Using a handheld RMLD upgraded with the advanced detection algorithms developed in this project, from within a moving vehicle we readily detected leaks created along the 7.4 mile route of a virtual gas transmission pipeline.

  4. Comparative study of instantaneous frequency based methods for leak detection in pipeline networks

    Science.gov (United States)

    Ghazali, M. F.; Beck, S. B. M.; Shucksmith, J. D.; Boxall, J. B.; Staszewski, W. J.

    2012-05-01

    Methods of pressure transient analysis can be seen as a promising, accurate and low-cost tool for leak and feature detection in pipelines. Various systems have been developed by several groups of researchers in recent years. Such techniques have been successfully demonstrated under laboratory conditions but are not yet established for use with real field test data. The current paper presents a comparative study of instantaneous frequency analysis techniques based on pressure transients recorded within a live distribution network. The instantaneous frequency of the signals are analysed using the Hilbert transform (HT), the Normalised Hilbert transform (NHT), Direct Quadrature (DQ), Teager Energy Operator (TEO) and Cepstrum. This work demonstrates the effectiveness of the instantaneous frequency analysis in detecting a leaks and other features within the network. NHT and DQ allowed for the identification of the approximate location of leaks. The performance TEO is moderate, with Cepstrum being the worst performing method.

  5. Functionalized multi-walled carbon nanotube based sensors for distributed methane leak detection

    Science.gov (United States)

    This paper presents a highly sensitive, energy efficient and low-cost distributed methane (CH4) sensor system (DMSS) for continuous monitoring, detection and localization of CH4 leaks in natural gas infrastructure such as transmission and distribution pipelines, wells, and produc...

  6. Dynamic modeling in compressible flow systems for application in real time leak detection; Modelagem dinamica em redes de escoamento compressivel para aplicacoes a deteccao de vazamentos em tempo real

    Energy Technology Data Exchange (ETDEWEB)

    Pires Neto, Joaquim Pamponet [Universidade Federal, Rio de Janeiro, RJ (Brazil). Escola de Quimica. Lab. SDV - Dutos]. E-mail: joaquim@copene.com.br

    2002-06-01

    It is remarkable how there are hardly any computer tools that can build a transient behavioral analysis of process variables in a compressible flow, especially during starting and shutdown of plant. From this scenario, a modeling and dynamic simulation of compressible flow systems was built, and a computer method for detecting leaks in real time was presented. The phenomenon model is based on moment and continuity equations in transient basis. Unidimensional and isentropic natural gas flow was considered. The set of differential equations is solved through numerical integrations in time, using Runge-Kutta methods, after applying the finite elements method to spatial continuum. The suggested method for detection of leaks is based on the self-regressive stochastic parametric model. The procedure consist in generating process transient input and output data series, such as nodal pressures and flow rates in pipes, during the occurrence of the events programmed by the dynamic simulator and use them during training of IMO predictors in RX model structure, with constant update. The manifestation of a leak is detected by the instant deviation, statistically significant and beyond safety limits, between a group of predictions and the corresponding process measures. (author)

  7. Assessment of Field Experience Related to Pressurized Water Reactor Primary System Leaks

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Vikram Naginbhai; Ware, Arthur Gates; Atwood, Corwin Lee; Sattison, Martin Blaine; Hartley, Robert Scott; Hsu, C.

    1999-08-01

    This paper presents our assessment of field experience related to pressurized water reactor (PWR) primary system leaks in terms of their number of rates, how aging affects frequency of leak events, the safety significance of such leaks, industry efforts to reduce leaks, and effectiveness of current leak detection systems. We have reviewed the licensee event reports to identify the events that took place during 1985 to the third quarter of 1996, and reviewed related technical literature and visited PWR plants to analyze these events. Our assessment shows that USNRC licensees have taken effective actions to reduce the number of leak events. One main reason for this decreasing trend was the elimination or reportable leakages from valve stem packing after 1991. Our review of leak events related to vibratory fatigue reveals a statistically significant decreasing trend with age (years of operation), but not in calendar time. Our assessment of worldwide data on leakage caused by thermal fatigue cracking is that the fatigue of aging piping is a safety significant issue. Our review of leak events has identified several susceptible sites in piping having high safety significance; but the inspection of some of these sites is not required by the ASME Code. These sites may be included in the risk-informed inspection programs.

  8. Assessment of Field Experience Related to Pressurized Water Reactor Primary System Leaks

    Energy Technology Data Exchange (ETDEWEB)

    A. G. Ware; C. Hsu (USNRC); C. L. Atwood; M. B. Sattison; R. S. Hartley (INEEL); V. N. Shah

    1999-02-01

    This paper presents our assessment of field experience related to pressurized water reactor (PWR) primary system leaks in terms of their number and rates, how aging affects frequency of leak events, the safety significance of such leaks, industry efforts to reduce leaks, and effectiveness of current leak detection systems. We have reviewed the licensee event reports to identify the events that took place during 1985 to the third quarter of 1996, and reviewed related technical literature and visited PWR plants to analyze these events. Our assessment shows that USNRC licensees have taken effective actions to reduce the number of leak events. One main reason for this decreasing trend was the elimination or reportable leakages from valve stem packing after 1991. Our review of leak events related to vibratory fatigue reveals a statistically significant decreasing trend with age (years of operation), but not in calendar time. Our assessment of worldwide data on leakage caused by thermal fatigue cracking is that the fatigue of aging piping is a safety significant issue. Our review of leak events has identified several susceptible sites in piping having high safety significance; but the inspection of some of these sites is not required by the ASME Code. These sites may be included in the risk-informed inspection programs.

  9. Corrosion Evaluation of Tank 40 Leak Detection Box

    Energy Technology Data Exchange (ETDEWEB)

    Mickalonis, J.I.

    1999-07-29

    'Leak detection from the transfer lines in the tank farm has been a concern for many years because of the need to minimize exposure of personnel and contamination of the environment. The leak detection box (LDB) is one line of defense, which must be maintained to meet this objective. The evaluation of a failed LDB was one item from an action plan aimed at minimizing the degradation of LDBs. The Tank 40 LDB, which failed in service, was dug up and shipped to SRTC for evaluation. During a video inspection while in service, this LDB was found to have black tubercles on the interior, which suggested possible microbial involvement. The failure point, however, was believed to have occurred in the drain line from the transfer line jacket. Visual, metallurgical, and biological analyses were performed on the LDB. The analysis results showed that there was not any adverse microbiological growth or significant localized corrosion. The corrosion of the LDB was caused by exposure to aqueous environments and was typical of carbon steel pipes in soil environments.'

  10. Resilience to leaking--dynamic systems modeling of information security.

    Science.gov (United States)

    Hamacher, Kay

    2012-01-01

    Leaking of confidential material is a major threat to information security within organizations and to society as a whole. This insight has gained traction in the political realm since the activities of Wikileaks, which hopes to attack 'unjust' systems or 'conspiracies'. Eventually, such threats to information security rely on a biologistic argument on the benefits and drawbacks that uncontrolled leaking might pose for 'just' and 'unjust' entities. Such biological metaphors are almost exclusively based on the economic advantage of participants. Here, I introduce a mathematical model of the complex dynamics implied by leaking. The complex interactions of adversaries are modeled by coupled logistic equations including network effects of econo-communication networks. The modeling shows, that there might arise situations where the leaking envisioned and encouraged by Wikileaks and the like can strengthen the defending entity (the 'conspiracy'). In particular, the only severe impact leaking can have on an organization seems to originate in the exploitation of leaks by another entity the organization competes with. Therefore, the model suggests that leaks can be used as a `tactical mean' in direct adversary relations, but do not necessarily increase public benefit and societal immunization to 'conspiracies'. Furthermore, within the model the exploitation of the (open) competition between entities seems to be a more promising approach to control malicious organizations : divide-et-impera policies triumph here.

  11. Resilience to Leaking — Dynamic Systems Modeling of Information Security

    Science.gov (United States)

    Hamacher, Kay

    2012-01-01

    Leaking of confidential material is a major threat to information security within organizations and to society as a whole. This insight has gained traction in the political realm since the activities of Wikileaks, which hopes to attack ‘unjust’ systems or ‘conspiracies’. Eventually, such threats to information security rely on a biologistic argument on the benefits and drawbacks that uncontrolled leaking might pose for ‘just’ and ‘unjust’ entities. Such biological metaphors are almost exclusively based on the economic advantage of participants. Here, I introduce a mathematical model of the complex dynamics implied by leaking. The complex interactions of adversaries are modeled by coupled logistic equations including network effects of econo-communication networks. The modeling shows, that there might arise situations where the leaking envisioned and encouraged by Wikileaks and the like can strengthen the defending entity (the ‘conspiracy’). In particular, the only severe impact leaking can have on an organization seems to originate in the exploitation of leaks by another entity the organization competes with. Therefore, the model suggests that leaks can be used as a `tactical mean’ in direct adversary relations, but do not necessarily increase public benefit and societal immunization to ‘conspiracies’. Furthermore, within the model the exploitation of the (open) competition between entities seems to be a more promising approach to control malicious organizations : divide-et-impera policies triumph here. PMID:23227151

  12. Resilience to leaking--dynamic systems modeling of information security.

    Directory of Open Access Journals (Sweden)

    Kay Hamacher

    Full Text Available Leaking of confidential material is a major threat to information security within organizations and to society as a whole. This insight has gained traction in the political realm since the activities of Wikileaks, which hopes to attack 'unjust' systems or 'conspiracies'. Eventually, such threats to information security rely on a biologistic argument on the benefits and drawbacks that uncontrolled leaking might pose for 'just' and 'unjust' entities. Such biological metaphors are almost exclusively based on the economic advantage of participants. Here, I introduce a mathematical model of the complex dynamics implied by leaking. The complex interactions of adversaries are modeled by coupled logistic equations including network effects of econo-communication networks. The modeling shows, that there might arise situations where the leaking envisioned and encouraged by Wikileaks and the like can strengthen the defending entity (the 'conspiracy'. In particular, the only severe impact leaking can have on an organization seems to originate in the exploitation of leaks by another entity the organization competes with. Therefore, the model suggests that leaks can be used as a `tactical mean' in direct adversary relations, but do not necessarily increase public benefit and societal immunization to 'conspiracies'. Furthermore, within the model the exploitation of the (open competition between entities seems to be a more promising approach to control malicious organizations : divide-et-impera policies triumph here.

  13. Leak detection in gas pipeline by acoustic and signal processing - A review

    Science.gov (United States)

    Adnan, N. F.; Ghazali, M. F.; Amin, M. M.; Hamat, A. M. A.

    2015-12-01

    The pipeline system is the most important part in media transport in order to deliver fluid to another station. The weak maintenance and poor safety will contribute to financial losses in term of fluid waste and environmental impacts. There are many classifications of techniques to make it easier to show their specific method and application. This paper's discussion about gas leak detection in pipeline system using acoustic method will be presented in this paper. The wave propagation in the pipeline is a key parameter in acoustic method when the leak occurs and the pressure balance of the pipe will generated by the friction between wall in the pipe. The signal processing is used to decompose the raw signal and show in time- frequency. Findings based on the acoustic method can be used for comparative study in the future. Acoustic signal and HHT is the best method to detect leak in gas pipelines. More experiments and simulation need to be carried out to get the fast result of leaking and estimation of their location.

  14. Development of a water leak detection system for LMFBR steam generator. Pt. 3. Experimental results for detection of bubbles using the SG sector model

    Energy Technology Data Exchange (ETDEWEB)

    Kumagai, Hiromichi; Yoshida, Kazuo [Central Research Inst. of Electric Power Industry, Komae, Tokyo (Japan). Komae Research Lab.

    1995-05-01

    In order to prevent the expansion of tube damages and to maintain structural safety in steam generators (SG) of liquid metal fast breeder reactor (LMFBR), it is necessary to detect precisely and immediately the leakage of water from tubes of heat exchangers. The active acoustic detection method, which detects the sound attenuation due to bubbles generated at the sodium-water reactions, has drawn general interests owing to its short response time and reduction of the influence of background noise. Sound attenuation is also subjected to structures such as heat transfer tubes and shrouds. Accordingly, it is necessary to evaluate the sound attenuation due to structures. However, studies in these respects are very few. In this paper, using the water bath and SG sector model, the attenuation characteristics of sounds due to flat plates and heat transfer tubes are investigated under various conditions and discussed. (author).

  15. Development, application & assessment of improved condenser leak detection program at Brayton Point Station

    Energy Technology Data Exchange (ETDEWEB)

    Medina, C.A.; Bennett, B.A.; Thornton, M.W.

    1996-08-01

    The adverse impacts of air inleakage on condenser performance are well known and include elevated turbine back pressure, increased parasitic loads (to remove elevated levels of noncondensables from the condenser), and high dissolved oxygen levels in the feedwater cycle. Prolonged neglect of leakage leads to increased maintenance to feedwater and air removal systems as well as reduced cycle efficiency and the potential of a unit trip on high turbine back pressure. Leak detection performed on a scheduled basis, just prior to a scheduled outage, is an effective preventive maintenance activity for older stations and important for newer stations concerned with heat rate degradation and equipment performance. New England Power began a comprehensive air inleakage reduction program at its Brayton Point Generating Station (BPS) in 1990. The authors describe the development and application on Units 1 through 4, including its unique identification and documentation tools and its computerized leak source tracking and trending software program. Actual results gained from the programs use at BPS will be presented. To put the merits of the program in perspective, historically, many real and potentially large leak paths were not being tested, because helium leak detection crews normally inspected familiar and easy-to-reach areas around the condenser. Tracking and trending was practically non-existent, providing little documentation for root cause analysis when a large leak is suspect. Since the improved program was implemented at BPS, air in-leakage detection has increased by 300 percent, in-leakage rates have reduced 40% and turbine backpressure levels have improved. Station personnel now have a tool to diagnose condenser air in-leakage with test repeatability, whether it be a sudden incident of high in-leakage demanding immediate testing and repair or gradual increases which can be identified during pre-outage testing for repair during their scheduled outage. 3 figs., 2 tabs.

  16. Detection of leaks in buried rural water pipelines using thermal infrared images

    Science.gov (United States)

    Eidenshink, Jeffery C.

    1985-01-01

    Leakage is a major problem in many pipelines. Minor leaks called 'seeper leaks', which generally range from 2 to 10 m3 per day, are common and are difficult to detect using conventional ground surveys. The objective of this research was to determine whether airborne thermal-infrared remote sensing could be used in detecting leaks and monitoring rural water pipelines. This study indicates that such leaks can be detected using low-altitude 8.7- to 11.5. micrometer wavelength, thermal infrared images collected under proper conditions.

  17. Steel Casing Resistivity Technology (SCRT): Innovative Applications of Electrical Methods for Buried Tank Leak Detection

    Science.gov (United States)

    Fink, J. B.; Levitt, M. T.; Gee, G. W.

    2002-12-01

    The need for non-invasive leak detection methods is extremely important for monitoring cleanup efforts of nuclear waste contained in underground storage tanks at the Hanford Nuclear Facility in Washington. Drilling is both very expensive and undesirable in the tank farms. Various geophysical imaging methods were evaluated over the past two years at two "cold" sites but within geologic conditions similar to the tank farms. The "cold" sites consisted of 1. a dense array of 32 steel casings, and 2. a "mock tank" in which various controlled leaks (injections) of a saturated aqueous solution of Na2S2O35H20 were metered. Nearly all methods required invasive drilling for subsurface placement of sensors. An innovative direct-current electrical method using existing infrastructure as grounding electrodes, such as steel casings and steel tanks, has shown very promising results and is undergoing further testing. The most useful results have been obtained by using multiple grounding points for spatial determinations and continuous time-series monitoring for temporal variations. Although the large size of tanks and lengths of casings make discrete volume estimations difficult, data acquired for test leaks to date have shown a surprising correlation between leak rates and the rate-of-change of specific electrical measurements. First order volume approximations can be made based on existing knowledge of the geologic environment and hydraulic parameters. Spatial data provide general leak location and gross flow characteristics, whereas temporal data indicate test leak commencement, cessation, and approximate leak rates. On-going testing is providing quantitative calibration information that is expected to transfer to the tank farm environments. Procedures are being developed that will simplify the installation and operation of the system in the tank-farm environments. Implementation of the technology necessitated remote operation and monitoring of the electrical system

  18. Advanced conceptual design report: T Plant secondary containment and leak detection upgrades. Project W-259

    Energy Technology Data Exchange (ETDEWEB)

    Hookfin, J.D.

    1995-05-12

    The T Plant facilities in the 200-West Area of the Hanford site were constructed in the early 1940s to produce nuclear materials in support of national defense activities. T Plant includes the 271-T facility, the 221-T facility, and several support facilities (eg, 2706-T), utilities, and tanks/piping systems. T Plant has been recommended as the primary interim decontamination facility for the Hanford site. Project W-259 will provide capital upgrades to the T Plant facilities to comply with Federal and State of Washington environmental regulations for secondary containment and leak detection. This document provides an advanced conceptual design concept that complies with functional requirements for the T Plant Secondary Containment and Leak Detection upgrades.

  19. Evaluation of an Interferometric Sensor for In-Space Detection of Gas Leaks

    Science.gov (United States)

    Polzin, Kurt A.; Korman, Valentin; Sinko, John; Hendrickson, Adam

    2009-01-01

    Space mission planning often involves long-term storage of volatile liquids or high-pressure gases. These may include cryogenic fuels and oxidizers, high-pressure gases, and life-support-critical consumables. The risk associated with the storage of fluids and gases in space systems has long been an issue and the ability to retain these fluids is often tied to mission success. A leak in the storage or distribution system can cause many different problems, including a simple, but mission endangering, loss of inventory or, in severe cases, unbalanced thrust loads on a flight vehicle. Cryogenic propellants are especially difficult to store, especially over a long duration. The propellant can boil off and be lost through the insulating walls of the tank or simple thermal cycling of the fittings, valves, and propellant feed lines may unseat seals allowing the fluid to escape. Current NASA missions call for long-duration in-space storage of propellants, oxidizers, and life support supplies. Leaks of a scale detectable through a pressure drop in the storage tank are often catastrophic and have long been the focus of ground-based mitigation efforts where redundant systems are often employed. However, there is presently no technology available for detecting and monitoring low-level, but still mission-endangering, gas leaks in space. Standard in-space gas detection methods either have a very limited pressure range over which they operate effectively or are limited to certain gases. Mass spectrometer systems are able to perform the detection tasks, but their size, mass and use of high voltage, which could potentially lead to an arc that ignites a combustible propellent, severely limit their usefulness in a space system. In this paper, we present results from testing of the light-based interferometric gas monitoring and leak detection sensor shown in Fig. 1. The output of the sensor is an interference fringe pattern that is a function of the gas density, and commensurate index

  20. Soil Surface Leak Detection From Carbon Storage Sites Using ∆(CO2:O2) Measurements

    Science.gov (United States)

    Alam, M. M.; Norman, A. L.; Layzell, D. B.

    2015-12-01

    The early detection and remediation of CO2 leaks from Carbon Capture and Storage (CCS) sites is essential for the safety and public support of the technology. A model that integrates gas diffusion, mass flow and biological processes in soils was developed and used to predict the ∆CO2 and ∆O2 concentration differential between the soil surface and the bulk atmosphere under a wide range of environmental conditions that include temperature, soil gas and water content, soil respiratory quotient and rate of O2 uptake, soil porosity and CO2 leakage rate. The results predicted that measurement of ∆(CO2:O2) measurements at the soil surface relative to air should be able to detect a CCS leak as low as 2 µmol/m2/sec. To test this hypothesis, a gas analysis system was designed and constructed. It should allow a series of experiments under controlled conditions to test all aspects of the model. It is hoped that the results from this work will ultimately lead to the development of a new instrument and protocol for the early detection of CO2 leaks from a geological storage sites.

  1. 基于太阳能充电的无线远程监控氯气泄漏系统%Wireless Remote Monitor System of Detecting the Leaking of Chlorine Gas Based on Solar Energy Charging

    Institute of Scientific and Technical Information of China (English)

    王金辉; 周巧娣; 徐勤利; 蒋科学; 陈文华

    2013-01-01

    根据工业用氯气的量大以及罐体存储的需求,选用基于GSM的远程监控系统对氯气泄漏进行检测.用太阳能电池板实现白天对系统供电以及对锂电池充电,夜晚完全由锂电池对供电.系统微控制器选用MSP430,以达到超低功耗的功能.对于氯气泄漏的信号采集使用CL2-A1电化学式氯气传感器,实现到对泄漏氯气快速检测做出反应的效果.该设计具有适用范围广,通用性强,能现场以及远程报警等优点.%Based on the large amount of chlorine for industrial use and storage of tank requirements, GSM-based remote monitoring system is selected to detect chlorine leaks. During the day the system uses solar panels as the system power supply and battery charger, but lithium-powered by night. In order to achieve ultra-low power consumption features, system uses ultra-low power microcontroller's MSP430. For acquisition of chlorine leakage signal, CL2 - Al Electrochemical chlorine sensor is used in the design, in order to achieve a rapid detection of chlorine leak response effect. The design has advantages of wide range of application, versatility, and can site and remote alarm.

  2. Hyperspectral detection of a subsurface CO2 leak in the presence of water stressed vegetation.

    Science.gov (United States)

    Bellante, Gabriel J; Powell, Scott L; Lawrence, Rick L; Repasky, Kevin S; Dougher, Tracy

    2014-01-01

    Remote sensing of vegetation stress has been posed as a possible large area monitoring tool for surface CO2 leakage from geologic carbon sequestration (GCS) sites since vegetation is adversely affected by elevated CO2 levels in soil. However, the extent to which remote sensing could be used for CO2 leak detection depends on the spectral separability of the plant stress signal caused by various factors, including elevated soil CO2 and water stress. This distinction is crucial to determining the seasonality and appropriateness of remote GCS site monitoring. A greenhouse experiment tested the degree to which plants stressed by elevated soil CO2 could be distinguished from plants that were water stressed. A randomized block design assigned Alfalfa plants (Medicago sativa) to one of four possible treatment groups: 1) a CO2 injection group; 2) a water stress group; 3) an interaction group that was subjected to both water stress and CO2 injection; or 4) a group that received adequate water and no CO2 injection. Single date classification trees were developed to identify individual spectral bands that were significant in distinguishing between CO2 and water stress agents, in addition to a random forest classifier that was used to further understand and validate predictive accuracies. Overall peak classification accuracy was 90% (Kappa of 0.87) for the classification tree analysis and 83% (Kappa of 0.77) for the random forest classifier, demonstrating that vegetation stressed from an underground CO2 leak could be accurately discerned from healthy vegetation and areas of co-occurring water stressed vegetation at certain times. Plants appear to hit a stress threshold, however, that would render detection of a CO2 leak unlikely during severe drought conditions. Our findings suggest that early detection of a CO2 leak with an aerial or ground-based hyperspectral imaging system is possible and could be an important GCS monitoring tool.

  3. Hyperspectral detection of a subsurface CO2 leak in the presence of water stressed vegetation.

    Directory of Open Access Journals (Sweden)

    Gabriel J Bellante

    Full Text Available Remote sensing of vegetation stress has been posed as a possible large area monitoring tool for surface CO2 leakage from geologic carbon sequestration (GCS sites since vegetation is adversely affected by elevated CO2 levels in soil. However, the extent to which remote sensing could be used for CO2 leak detection depends on the spectral separability of the plant stress signal caused by various factors, including elevated soil CO2 and water stress. This distinction is crucial to determining the seasonality and appropriateness of remote GCS site monitoring. A greenhouse experiment tested the degree to which plants stressed by elevated soil CO2 could be distinguished from plants that were water stressed. A randomized block design assigned Alfalfa plants (Medicago sativa to one of four possible treatment groups: 1 a CO2 injection group; 2 a water stress group; 3 an interaction group that was subjected to both water stress and CO2 injection; or 4 a group that received adequate water and no CO2 injection. Single date classification trees were developed to identify individual spectral bands that were significant in distinguishing between CO2 and water stress agents, in addition to a random forest classifier that was used to further understand and validate predictive accuracies. Overall peak classification accuracy was 90% (Kappa of 0.87 for the classification tree analysis and 83% (Kappa of 0.77 for the random forest classifier, demonstrating that vegetation stressed from an underground CO2 leak could be accurately discerned from healthy vegetation and areas of co-occurring water stressed vegetation at certain times. Plants appear to hit a stress threshold, however, that would render detection of a CO2 leak unlikely during severe drought conditions. Our findings suggest that early detection of a CO2 leak with an aerial or ground-based hyperspectral imaging system is possible and could be an important GCS monitoring tool.

  4. Leak Detection Modeling and Simulation for Oil Pipeline with Artificial Intelligence Method

    Directory of Open Access Journals (Sweden)

    Pudjo Sukarno

    2007-05-01

    Full Text Available Leak detection is always interesting research topic, where leak location and leak rate are two pipeline leaking parameters that should be determined accurately to overcome pipe leaking problems. In this research those two parameters are investigated by developing transmission pipeline model and the leak detection model which is developed using Artificial Neural Network. The mathematical approach needs actual leak data to train the leak detection model, however such data could not be obtained from oil fields. Therefore, for training purposes hypothetical data are developed using the transmission pipeline model, by applying various physical configuration of pipeline and applying oil properties correlations to estimate the value of oil density and viscosity. The various leak locations and leak rates are also represented in this model. The prediction of those two leak parameters will be completed until the total error is less than certain value of tolerance, or until iterations level is reached. To recognize the pattern, forward procedure is conducted. The application of this approach produces conclusion that for certain pipeline network configuration, the higher number of iterations will produce accurate result. The number of iterations depend on the leakage rate, the smaller leakage rate, the higher number of iterations are required. The accuracy of this approach is clearly determined by the quality of training data. Therefore, in the preparation of training data the results of pressure drop calculations should be validated by the real measurement of pressure drop along the pipeline. For the accuracy purposes, there are possibility to change the pressure drop and fluid properties correlations, to get the better results. The results of this research are expected to give real contribution for giving an early detection of oil-spill in oil fields.

  5. Doppler method leak detection for LMFBR steam generators. Pt. 3. Investigation of detection sensitivity and method

    Energy Technology Data Exchange (ETDEWEB)

    Kumagai, Hiromichi; Kinoshita, Izumi [Central Research Inst. of Electric Power Industry, Komae, Tokyo (Japan). Komae Research Lab

    2001-04-01

    To prevent the expansion of tube damage and to maintain structural integrity in the steam generators (SGs) of a fast breeder reactor (FBR), it is necessary to detect precisely and immediately any leakage of water from heat transfer tubes. Therefore, the Doppler method was developed. Previous studies have revealed that, in the SG full-sector model that simulates actual SGs, the Doppler method can detect bubbles of 0.4 l/s within a few seconds. However in consideration of the dissolution rate of hydrogen generated by a sodium-water reaction even from a small water leak, it is necessary to detect smaller leakages of water from the heat transfer tubes. The detection sensitivity of the Doppler method and the influence of background noise were experimentally investigated. In-water experiments were performed using the SG model. The results show that the Doppler method can detect bubbles of 0.01 l/s (equivalent to a water leak rate of about 0.01 g/s) within a few seconds and that the background noise has little effect on water leak detection performance. The Doppler method thus has great potential for the detection of water leakage in SGs. (author)

  6. Multiple-Feature Extracting Modules Based Leak Mining System Design

    Science.gov (United States)

    Cho, Ying-Chiang; Pan, Jen-Yi

    2013-01-01

    Over the years, human dependence on the Internet has increased dramatically. A large amount of information is placed on the Internet and retrieved from it daily, which makes web security in terms of online information a major concern. In recent years, the most problematic issues in web security have been e-mail address leakage and SQL injection attacks. There are many possible causes of information leakage, such as inadequate precautions during the programming process, which lead to the leakage of e-mail addresses entered online or insufficient protection of database information, a loophole that enables malicious users to steal online content. In this paper, we implement a crawler mining system that is equipped with SQL injection vulnerability detection, by means of an algorithm developed for the web crawler. In addition, we analyze portal sites of the governments of various countries or regions in order to investigate the information leaking status of each site. Subsequently, we analyze the database structure and content of each site, using the data collected. Thus, we make use of practical verification in order to focus on information security and privacy through black-box testing. PMID:24453892

  7. Design of an Infrared Imaging System for Robotic Inspection of Gas Leaks in Industrial Environments

    Directory of Open Access Journals (Sweden)

    Ramon Barber

    2015-03-01

    Full Text Available Gas detection can become a critical task in dangerous environments that involve hazardous or contaminant gases, and the use of imaging sensors provides an important tool for leakage location. This paper presents a new design for remote sensing of gas leaks based on infrared (IR imaging techniques. The inspection system uses an uncooled microbolometer detector, operating over a wide spectral bandwidth, that features both low size and low power consumption. This equipment is boarded on a robotic platform, so that wide objects or areas can be scanned. The detection principle is based on the use of active imaging techniques, where the use of external IR illumination enhances the detection limit and allows the proposed system to operate in most cases independently from environmental conditions, unlike passive commercial approaches. To illustrate this concept, a fully radiometric description of the detection problem has been developed; CO2 detection has been demonstrated; and simulations of typical gas detection scenarios have been performed, showing that typical industrial leaks of CH4 are well within the detection limits. The mobile platform where the gas sensing system is going to be implemented is a robot called TurtleBot. The control of the mobile base and of the inspection device is integrated in ROS architecture. The exploration system is based on the technique of Simultaneous Localization and Mapping (SLAM that makes it possible to locate the gas leak in the map.

  8. Detection of bile duct leaks using MR cholangiography with mangfodipir trisodium (Teslascan).

    Science.gov (United States)

    Vitellas, K M; El-Dieb, A; Vaswani, K; Bennett, W F; Fromkes, J; Steinberg, S; Bova, J G

    2001-01-01

    Mangafodipir trisodium (Teslascan), a hepatobiliary contrast agent, has the potential of providing functional biliary imaging similar to hepatobiliary scintigraphy. To our knowledge. the potential role of this biliary contrast agent in the detection of bile duct leaks has not been reported. In this case report, we report the first case of a bile duct leak diagnosed with enhanced MRI with mangafodipir trisodium in a patient following laparoscopic cholecystectomy. Our case illustrates that functional MR cholangiography images can be successfully acquired by using a post-mangafodipir fat-suppressed GRE technique and that bile duct leaks can be detected.

  9. Using Decision Trees to Detect and Isolate Leaks in the J-2X

    Data.gov (United States)

    National Aeronautics and Space Administration — Full title: Using Decision Trees to Detect and Isolate Simulated Leaks in the J-2X Rocket Engine Mark Schwabacher, NASA Ames Research Center Robert Aguilar, Pratt...

  10. The Design of Intelligent System for Gas Leak Detection in Substation%变电站气体泄漏检测的智能系统设计

    Institute of Scientific and Technical Information of China (English)

    苏镇西; 马凤翔; 吴雪莲

    2016-01-01

    针对传统变电站气体泄漏检测工作中存在的工作效率低、安全性差且误差较大等问题,提出了一种基于磁导航和RFID定位、3G无线通信网络等技术的气体泄漏智能检测系统。该系统通过3G无线通信网络将变电站气体泄漏AGV巡检采集的现场数据信息,实时传输到后台管理系统和监控管理中心,便于监管人员动态掌握变电站设备气体泄漏情况和运行工况,从而科学制定安排维护工作,为设备气体泄漏检修和状态管理提供重要参考依据。%There are some defects in traditional substation gas leakage detection, such as low work efficiency, poor security and larger error. To overcome these shortcomings, an intelligent system of gas leakage detection is proposed and implemented based on magnetic navigation, RFID location and 3G wireless network. This system achieves the field information data collected by AGV, and delivered to the central server system through 3G wireless network. It can provide an important reference to build the scientifically gas leakage detection and maintenance management work.

  11. Small-target leak detection for a closed vessel via infrared image sequences

    Science.gov (United States)

    Zhao, Ling; Yang, Hongjiu

    2017-03-01

    This paper focus on a leak diagnosis and localization method based on infrared image sequences. Some problems on high probability of false warning and negative affect for marginal information are solved by leak detection. An experimental model is established for leak diagnosis and localization on infrared image sequences. The differential background prediction is presented to eliminate the negative affect of marginal information on test vessel based on a kernel regression method. A pipeline filter based on layering voting is designed to reduce probability of leak point false warning. A synthesize leak diagnosis and localization algorithm is proposed based on infrared image sequences. The effectiveness and potential are shown for developed techniques through experimental results.

  12. Development of microphone leak detection technology in Fugen Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Shimanskiy, Sergey; Iijima, Takashi; Naoi, Yosuke [Japan Nuclear Cycle Development Inst., Fugen Nuclear Power Station, Tsuruga, Fukui (Japan)

    2002-06-01

    A method of leak detection, based on high-temperature resistant microphones, was originally developed in JNC to detect leakages with flow rates from 1 m{sup 3}/h to 500 m{sup 3}/h. The development performed in Fugen and reported here focuses on detection of a small leakage at an early stage by the same microphone method. Specifically, for the inlet feeder pipes the leak rate of 0.2 gpm (0.046 m{sup 3}/h) has been chosen as the target detection capability. Evaluation of detection sensitivity and leak localization accuracy was conducted based on various analysis methods in order to check the capability of the method to satisfy this requirement. The possibility of detecting and locating a small leakage has been demonstrated through the research. The probabilistic detection algorithm and multi-channel location-based detection are proposed in order to improve both the detection sensitivity and the localization accuracy. (author)

  13. Application of Morphological Segmentation to Leaking Defect Detection in Sewer Pipelines

    Directory of Open Access Journals (Sweden)

    Tung-Ching Su

    2014-05-01

    Full Text Available As one of major underground pipelines, sewerage is an important infrastructure in any modern city. The most common problem occurring in sewerage is leaking, whose position and failure level is typically identified through closed circuit television (CCTV inspection in order to facilitate rehabilitation process. This paper proposes a novel method of computer vision, morphological segmentation based on edge detection (MSED, to assist inspectors in detecting pipeline defects in CCTV inspection images. In addition to MSED, other mathematical morphology-based image segmentation methods, including opening top-hat operation (OTHO and closing bottom-hat operation (CBHO, were also applied to the defect detection in vitrified clay sewer pipelines. The CCTV inspection images of the sewer system in the 9th district, Taichung City, Taiwan were selected as the experimental materials. The segmentation results demonstrate that MSED and OTHO are useful for the detection of cracks and open joints, respectively, which are the typical leakage defects found in sewer pipelines.

  14. 基于混沌理论的城市供水系统漏损检测新方法%A New Method to Leak Detection in Water System Based on Chaos Theory

    Institute of Scientific and Technical Information of China (English)

    张琴; 朱庆建; 汪雄海

    2013-01-01

    Considering the importance of leak detection to energy efficiency in urban water system,a new method to leak detection based on chaos theory is presented.The chaotic evolutional characters of successive users were used to detect pipe break or the leakage.By extracting the correlation dimension、Lyapunov exponent、attractor phase diagram and R/S analysis of hourly water consumption,the water time series of successive users were proved to be fractal and chaotic chaining relevant.On the basis,the different chaotic characters of booster and leakage were compared by phase diagram and the maximum Lyapunov exponent variation.Test results show that the chaotic characters are changed immediately when the booster occurs,and slow leakage can be discovered after two hours.Thus this method supplies new judgments to effectively amend water system in time and decrease the loss of water resource.%针对漏损检测对城市供水系统节能降耗的重要性,研究时用水量的混沌特性并提出一种基于混沌理论的漏损检测新方法,利用沿程用户时用水量的混沌演化特性来检测漏损故障和漏水.根据城市时用水量的时间序列,提取关联维数、最大Lyapunov指数、吸引子相图和R/S等混沌特征指数,分析沿程城市用水量观测序列的分形和链级混沌关联,并在此基础上,依据系统相图和最大Lyapunov指数变化来比较漏损故障和漏水时序的不同混沌特性.仿真结果表明,漏损故障时的混沌特性显著改变并能立即检测到,缓慢漏水2h后混沌特性变化明显,为及时修补供水系统提供依据,减小了资源损耗.

  15. Technical basis for inner container leak detection sensitivity goals in 3013 DE surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Berg, John M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-11

    Helium leak checking of 3013 inner container lids is under consideration for addition to DE Surveillance tasks as an improved means to detect any through-wall flaws that may have formed during storage. This white paper evaluates whether leak checking at DE could replace and improve upon the current method of comparing gas compositions and pressures within the inner and outer containers. We have used viscous and molecular flow equations in ANSI N14.5 to calculate what the measured standard helium leak rate would be for hypothetical leaks of three different sizes. For comparison, we have also calculated the effects on gas composition and pressure differences as a function of pre-DE storage time for the same three leak sizes, using molecular and viscous flow equations as well as diffusion equations to predict the relevant gas transport. For a hypothetical leak that would be measured at 1x10-7 std cc/sec, likely an achievable sensitivity using helium leak checking at DE, the calculations predict no measurable effect on pressure difference or gas composition as measured by DE gas analysis. We also calculate that it would take over 200 years for water vapor to diffuse through a 10-7 std cc/sec leak enough to raise the RH outer container to half the RH value in the inner container. A leak 100 times larger, which would be measured at 1x10-5 std cc/sec, the same water vapor diffusion would take at least 14 years. Our conclusion is that helium leak checking will be useful even at a sensitivity of 1x10-5 std cc/sec, and a significant improvement over current DE methods at a sensitivity of 1x10-7 std cc/sec.

  16. Spontaneous Intracranial Hypotension With Site of Leak Detected Only After 111In-DTPA Cisternogram.

    Science.gov (United States)

    Parsian, Sana; Matesan, Manuela C; Kumbhar, Sachin Shivaji; Lewis, David H

    2017-04-01

    A 54-year-old man with a 3-week history of orthostatic headache and acute on chronic subdural hematoma presented with imaging findings suggestive of spontaneous intracranial hypotension. Three myelograms were negative for leak, and nontargeted epidural blood patches did not result in symptom relief. A cerebrospinal fluid leak study using In-DTPA with SPECT/CT demonstrated a focal area of asymmetric activity at the left C2 nerve root. A left C2 root tie-off, targeted epidural blood patch, and Dura seal glue resulted in resolution of patient symptomatology highlighting the importance of fused SPECT/CT images in detection of an occult cerebral spinal fluid leak.

  17. New Sensor Cable for the Detection and Location of Leaks in Pipelines for Transportation of Hydrocarbons

    Directory of Open Access Journals (Sweden)

    E.Orduña-Reyes

    2012-08-01

    Full Text Available At present, hydrocarbon leaks, generated mainly by corrosion of pipelines, cause large economic losses for Mexico.These leaks constitute a problem of serious consequences in Mexico and in other countries in the world. This workdescribes the results of the tests conducted on a new sensor cable for the detection and location of leaks in pipelinesfor transportation of hydrocarbons. When a liquid or gas enters in contact with the wall of the sensor cable, it causes ashort circuit in the wires; changing the measurement of the resistance may detect and locate the leak. The new sensorcable that is presented in this article has advantages over cables with similar characteristic made in other countries.The use of this sensor cable in pipelines of PEMEX will avoid economic losses, environmental damage and risks ofpossible explosions to the population. The experimental results demonstrate these advantages.

  18. Leak detection technologies for oil and gas pipelines; Tecnologias para deteccao e localizacao de vazamento em dutos de oleo e ou gas

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, Julio R. [MTT Aselco Automacao Ltda., Sao Paulo, SP (Brazil)

    2005-07-01

    Two concepts are available for leak detection in oil and/or gas pipelines: On-line leak detection system and off-line leak detection technique. The off-line leak detection technique is, usually, portable and does net configure a 'system'. This technique includes hydro-test, acoustic emission of high frequency, tracer of chemical substances, ultrasonic flow meter (UT), thermographic infra-red mapping, electromagnetic offset registration, etc. Since most of those methods requests stop of the system or depend on direct and detailed inspection of the whole monitored piping they are limited to the off-line inspection. In the current days there are only two technologies applied to detect and locate leaks on-line: The acoustic Leak Detection System and the modeling of computerized simulation also called as RTM (Real Time Modeling), RTTM or Mass Balance. There are still other techniques in the market, as acoustic emission, pressure analysis (PPA) beyond other rough techniques, without good results. Even some of these techniques are working without success, they are still used to accomplish with government standards. (author)

  19. Leak detection in medium density polyethylene (MDPE) pipe using pressure transient method

    Science.gov (United States)

    Amin, M. M.; Ghazali, M. F.; PiRemli, M. A.; Hamat, A. M. A.; Adnan, N. F.

    2015-12-01

    Water is an essential part of commodity for a daily life usage for an average person, from personal uses such as residential or commercial consumers to industries utilization. This study emphasizes on detection of leaking in medium density polyethylene (MDPE) pipe using pressure transient method. This type of pipe is used to analyze the position of the leakage in the pipeline by using Ensemble Empirical Mode Decomposition Method (EEMD) with signal masking. Water hammer would induce an impulse throughout the pipeline that caused the system turns into a surge of water wave. Thus, solenoid valve is used to create a water hammer through the pipelines. The data from the pressure sensor is collected using DASYLab software. The data analysis of the pressure signal will be decomposed into a series of wave composition using EEMD signal masking method in matrix laboratory (MATLAB) software. The series of decomposition of signals is then carefully selected which reflected intrinsic mode function (IMF). These IMFs will be displayed by using a mathematical algorithm, known as Hilbert transform (HT) spectrum. The IMF signal was analysed to capture the differences. The analyzed data is compared with the actual measurement of the leakage in term of percentage error. The error recorded is below than 1% and it is proved that this method highly reliable and accurate for leak detection.

  20. Detecting proton exchange membrane fuel cell hydrogen leak using electrochemical impedance spectroscopy method

    Science.gov (United States)

    Mousa, Ghassan; Golnaraghi, Farid; DeVaal, Jake; Young, Alan

    2014-01-01

    When a proton exchange membrane (PEM) fuel cell runs short of hydrogen, it suffers from a reverse potential fault that, when driven by neighboring cells, can lead to anode catalyst degradation and holes in the membrane due to local heat generation. As a result, hydrogen leaks through the electrically-shorted membrane-electrode assembly (MEA) without being reacted, and a reduction in fuel cell voltage is noticed. Such voltage reduction can be detected by using electrochemical impedance spectroscopy (EIS). To fully understand the reverse potential fault, the effect of hydrogen crossover leakage in a commercial MEA is measured by EIS at different differential pressures between the anode and cathode. Then the signatures of these leaky cells were compared with the signatures of a no-leaky cells at different oxygen concentrations with the same current densities. The eventual intent of this early stage work is to develop an on-board diagnostics system that can be used to detect and possibly prevent cell reversal failures, and to permit understanding the status of crossover or transfer leaks versus time in operation.

  1. 75 FR 76742 - Detecting Oil Leaks From Vessels Into the Water

    Science.gov (United States)

    2010-12-09

    ... SECURITY Coast Guard Detecting Oil Leaks From Vessels Into the Water AGENCY: Coast Guard, DHS. ACTION... seeks information about the current state of technology to detect loss of oil into the water. DATES... about the current state of technology to detect loss of oil into the water. All information...

  2. Pressure based leak detection system implanted on the business Unit Exploration and Production of PETROBRAS in Rio Grande do Norte e Ceara; Sistema de deteccao de vazamentos em dutos baseado em pressao implantado na Unidade de Negocios de Exploracao e Producao da PETROBRAS no Rio de Grande do Norte e Ceara

    Energy Technology Data Exchange (ETDEWEB)

    Rolim, Tuerte A.; Oliveira, Abenildo A.de [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil)

    2003-07-01

    This paper presents the experience faced by people who works in PETROBRAS Business Unit (UN-RNCE), located in Rio Grande do Norte Province, Brazil, during the implementation of a pipeline leak detection system. That application involved nine multiphase oil pipelines distributed along several production facilities. Because of the emergency after the leakage that polluted the Guanabara bay and due to the two phases and multi phases pipelines characteristics, the UN-RNCE decided to apply the Pressure Point Analysis (PPA) technology in order to detect leakages. It is a statistical method for leak detection e uses a very simple instrumentation which facilitates the installation and maintenance. However, in order to get the best performance of the system, it is necessary to know thoroughly the whole process and have a fast and reliable SCADA system for long distance communication. Finally it will be shown the test results, the recommendations to expand the system and the conclusions. (author)

  3. Leak detection in spacecraft using structure-borne noise with distributed sensors

    Science.gov (United States)

    Holland, Stephen D.; Roberts, Ron; Chimenti, D. E.; Strei, Michael

    2005-04-01

    We have developed and tested in the laboratory a method for in-orbit detection and location of air leaks in manned spacecraft that uses only a small number of sensors distributed arbitrarily on the inner surface of the spacecraft skin. Then, structure-borne ultrasound in the range of 300-600 kHz is monitored from each of the sensors. When cross correlations between measured sensor waveforms indicate the presence of a leak, these correlations are compared with a large dynamically generated database of simulated correlations to locate the the leak on the pressure vessel. A series of experimental tests were performed and at worst the method identified some false locations, but the true location of the leak always appeared.

  4. Applications of a morphological scene change detection (MSCD) for visual leak and failure identification in process and chemical engineering

    Science.gov (United States)

    Tickle, Andrew J.; Harvey, Paul K.; Smith, Jeremy S.

    2010-10-01

    Morphological Scene Change Detection (MSCD) is a process typically tasked at detecting relevant changes in a guarded environment for security applications. This can be implemented on a Field Programmable Gate Array (FPGA) by a combination of binary differences based around exclusive-OR (XOR) gates, mathematical morphology and a crucial threshold setting. The additional ability to set up the system in virtually any location due to the FPGA makes it ideal for insertion into an autonomous mobile robot for patrol duties. However, security is not the only potential of this robust algorithm. This paper details how such a system can be used for the detection of leaks in piping for use in the process and chemical industries and could be deployed as stated in the above manner. The test substance in this work was water, which was pumped either as a liquid or as low pressure steam through a simple pipe configuration with holes at set points to simulate the leaks. These holes were situated randomly at either the center of a pipe (in order to simulate an impact to it) or at a joint or corner (to simulate a failed weld). Imagery of the resultant leaks, which were visualised as drips or the accumulation of steam, which where analysed using MATLAB to determine their pixel volume in order to calibrate the trigger for the MSCD. The triggering mechanism is adaptive to make it possible in theory for the type of leak to be determined by the number of pixels in the threshold of the image and a numerical output signal to state which of the leak situations is being observed. The system was designed using the DSP Builder package from Altera so that its graphical nature is easily comprehensible to the non-embedded system designer. Furthermore, all the data from the DSP Builder simulation underwent verification against MATLAB comparisons using the image processing toolbox in order to validate the results.

  5. The effects of air leaks on solar air heating systems

    Science.gov (United States)

    Elkin, R.; Cash, M.

    1979-01-01

    This paper presents the results of an investigation to determine the effects of leakages in collector and duct work on the system performance of a typical single-family residence solar air heating system. Positive (leakage out) and negative (leakage in) pressure systems were examined. Collector and duct leakage rates were varied from 10 to 30 percent of the system flow rate. Within the range of leakage rates investigated, solar contribution to heated space and domestic hot water loads was found to be reduced up to 30 percent from the no-leak system contribution with duct leakage equally divided between supply and return duct; with supply duct leakage greater than return leakage a reduction of up to 35 percent was noted. The negative pressure system exhibited a reduction in solar contribution somewhat larger than the positive pressure system for the same leakage rates.

  6. Field tests and commercialization of natural gas leak detectors

    Energy Technology Data Exchange (ETDEWEB)

    Choi, D.S.; Jeon, J.S.; Kim, K.D.; Cho, Y.A. [R and D Center, Korea Gas Corporation, Ansan (Korea)

    1999-09-01

    Objectives - (1) fields test of industrial gas leak detection monitoring system. (2) commericialization of residential gas leak detector. Contents - (1) five sets of gas leak detection monitoring system were installed at natural gas transmition facilities and tested long term stability and their performance. (2) improved residential gas leak detector was commercialised. Expected benefits and application fields - (1) contribution to the improvement of domestic gas sensor technology. (2) localization of fabrication technology for gas leak detectors. 23 refs., 126 figs., 37 tabs.

  7. Studies on the detection of leaks from Tapacura dam

    Energy Technology Data Exchange (ETDEWEB)

    Menezes, Marco O.A.; Andrade Lima, Ricardo de; Antonino, Antonio C.D.; Villar, Heldio P.; Oliveira Lira, Carlos A.B. de [Pernambuco Univ., Recife, PE (Brazil). Dept. de Energia Nuclear; Badeira, Jefferson V. [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil); Viana, Afonso A. [Companhia Pernambucana de Saneamento e Agua, Recife, PE (Brazil); Plata-Bedmar, Antonio [Centro de Estudios y Experimentaciones de Obras Publicas (Spain); Garcia-Agudo, Edmundo [International Atomic Energy Agency, Vienna (Austria)

    1997-12-01

    One of the many applications of stable isotope analyses is in hydrological studies. as the isotope concentration of elements in water vary as a result of fractionation due to physicochemical processes, each water has its own fingerprints, so that identification of its origin is made possible. This technique has been used in the investigation of the possible leaks through the geologic formation underneath the Tapacura Dam, near Recife, Brazil. Samples were collected from the reservoir and from several collection points downstream. These samples have been analysed for their deuterium, {sup 18} O and {sup 13} C concentrations. The comparison between results from these analyses indicated that water from the reservoir and from the other collection points had distinct origins. These finding were corroborated from standard chemical analyses and tracer studies, thus pointing to the absence of any significant underflow at the Tapacura Dam. (author). 4 refs., 1 fig., 4 tabs.

  8. An Amplitude-Based Estimation Method for International Space Station (ISS) Leak Detection and Localization Using Acoustic Sensor Networks

    Science.gov (United States)

    Tian, Jialin; Madaras, Eric I.

    2009-01-01

    The development of a robust and efficient leak detection and localization system within a space station environment presents a unique challenge. A plausible approach includes the implementation of an acoustic sensor network system that can successfully detect the presence of a leak and determine the location of the leak source. Traditional acoustic detection and localization schemes rely on the phase and amplitude information collected by the sensor array system. Furthermore, the acoustic source signals are assumed to be airborne and far-field. Likewise, there are similar applications in sonar. In solids, there are specialized methods for locating events that are used in geology and in acoustic emission testing that involve sensor arrays and depend on a discernable phase front to the received signal. These methods are ineffective if applied to a sensor detection system within the space station environment. In the case of acoustic signal location, there are significant baffling and structural impediments to the sound path and the source could be in the near-field of a sensor in this particular setting.

  9. Conceptual design report for the project to install leak detection in FAST-FT-534/548/549

    Energy Technology Data Exchange (ETDEWEB)

    Galloway, K.J.

    1992-07-01

    This report provides conceptual designs and design recommendations for installing secondary containment and leak detection systems for three sumps at the Fluorinel and Storage Facility (FAST), CPP-666. The FAST facility is located at the Idaho Chemical Processing Plant (ICPP) at the Idaho National Engineering Laboratory (INEL). The three sumps receive various materials from the FAST water treatment process. This project involves sump upgrades to meet appropriate environmental requirements. The steps include: providing sump modifications or designs for the installation of leak chases and/or leakage accumulation, coating the sump concrete with a chemical resistant sealant (except for sump VES-FT-534 which is already lined with stainless steel) to act as secondary containment, lining the sumps with a primary containment system, and providing a means to detect and remove primary containment leakage that may occur.

  10. Water Pipeline Monitoring and Leak Detection using Flow Liquid Meter Sensor

    Science.gov (United States)

    Rahmat, R. F.; Satria, I. S.; Siregar, B.; Budiarto, R.

    2017-04-01

    Water distribution is generally installed through underground pipes. Monitoring the underground water pipelines is more difficult than monitoring the water pipelines located on the ground in open space. This situation will cause a permanent loss if there is a disturbance in the pipeline such as leakage. Leaks in pipes can be caused by several factors, such as the pipe’s age, improper installation, and natural disasters. Therefore, a solution is required to detect and to determine the location of the damage when there is a leak. The detection of the leak location will use fluid mechanics and kinematics physics based on harness water flow rate data obtained using flow liquid meter sensor and Arduino UNO as a microcontroller. The results show that the proposed method is able to work stably to determine the location of the leak which has a maximum distance of 2 metres, and it’s able to determine the leak location as close as possible with flow rate about 10 litters per minute.

  11. [Usefulness of upper gastrointestinal series to detect leaks in the early postoperative period of bariatric surgery].

    Science.gov (United States)

    Medina, Francisco J; Miranda-Merchak, Andrés; Martínez, Alonso; Sánchez, Felipe; Bravo, Sebastián; Contreras, Juan Eduardo; Alliende, Isabel; Canals, Andrea

    2016-04-01

    Postoperative leaks are the most undesirable complication of bariatric surgery and upper gastrointestinal (GI) series are routinely ordered to rule them out. Despite the published literature recommending against its routine use, it is still being customarily used in Chile. To examine the usefulness of routine upper GI series using water-soluble iodinated contrast media for the detection of early postoperative leaks in patients undergoing bariatric surgery. A cohort of 328 patients subjected to bariatric surgery was followed from October 2012 to October 2013. Most of them underwent sleeve gastrectomy. Upper GI series on the first postoperative day were ordered to 308 (94%) patients. Postoperative leaks were observed in two patients, with an incidence of 0.6%. The sensitivity for upper GI series detection of leak was 0% and the negative predictive value was 99%. Routine upper GI series after bariatric surgery is not useful for the diagnosis of postoperative leak, given the low incidence of this complication and the low sensitivity of the technique.

  12. Idiopathic Systemic Capillary Leak Syndrome: A Case Report

    Science.gov (United States)

    Yardimci, Bulent; Kazancioglu, Rumeyza

    2016-01-01

    Introduction Idiopathic systemic capillary leak syndrome (ISCLS) is rarely seen, and presents with recurrent episodes of hypotension, shock, hemoconcentration, and hypoproteinemia. The main pathology is the dysfunction of the vascular endothelium, and it is characterized by an increase of capillary permeability that is accompanied by the loss of intravascular fluid and protein. Case Presentation We present a 58-year-old female who presented with peripheral edema, leg pain, and syncope at the emergency department. Interestingly demyemilising neuropathy, which is a rare finding, ensued on day 4. She is still being treated using intravenous immunoglobulin therapy. Conclusions The early signs and symptoms of ISCLS may be subtle; therefore the diagnosis can easily be missed and prompt treatment of the syndrome may be postponed. Thus, the clinician must consider ISCLS in differential diagnosis in cases of hypotension, hemoconcentration, and hypoalbuminemia. PMID:27195144

  13. Technical bases for leak detection surveillance of waste storage tanks. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, M.G.; Badden, J.J.

    1995-02-13

    This document provides the technical bases for specification limits, monitoring frequencies and baselines used for leak detection and intrusion (for single shell tanks only) in all single and double shell radioactive waste storage tanks, waste transfer lines, and most catch tanks and receiver tanks in the waste tank farms and associated areas at Hanford.

  14. Feasibility of leak-detection instrumentation for duplex-tube steam generator. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Berkey, E.; Witkowski, R.E.

    1974-01-01

    A literature search has been carried out to determine if current state-of-the-art for sodium vapor and water vapor detectors are feasible as leak detection instrumentation for the Westinghouse duplex-tube steam generator. A commercially available probe-type water vapor detector has been identified and a thermal ionization type sodium vapor detector, currently being developed by Westinghouse, has been selected as the reference sodium-vapor leak detector. Recommendations are made concerning the experimental studies required to adapt the selected instrumentation to steam-generator plant applications. Proposed future instrumentation development programs are also identified.

  15. Assessment of Early Leak-Detection Capabilities at a Commercial-Scale Carbon Capture and Storage Site

    Science.gov (United States)

    Williams, M. D.; Vermeul, V. R.; Oostrom, M.; Porse, S.

    2014-12-01

    In cooperation with the U.S. Department of Energy (DOE), a large Midwest carbon capture and storage (CCS) project will upgrade a power plant with oxy-combustion technology to capture approximately 1.1 million metric tons (MMT) of CO2 each year. This project will design and construct a first-of-its-kind, near-zero emissions coal-fueled power plant that incorporates CCS. The project will implement a suite of monitoring technologies that includes early-leak-detection monitoring directly above the primary confining zone in regions of increased leakage potential (e.g., near wells that penetrate the caprock). In support of early leak-detection monitoring systems design, numerical models were developed and used to evaluate the relative value of various leak detection metrics over a range of hypothetical leakage scenarios. This preliminary modeling evaluation was based on a simplified model that assumed uniform properties for each model layer and interrogated both pressure and geochemical response in the first permeable interval overlying the primary confining zone. Simulation results indicate that pressure is likely to be the earliest indicator of leakage, given the rapid and areally extensive nature of this response. Simulated geochemical signals are much more localized and take much longer to develop than the pressure responses. Because of the buoyancy effect associated with supercritical CO2 (scCO2), early leak-detection monitoring for these leakage scenarios would be best achieved through monitoring in the upper portion of the interval near the contact with overlying low-permeability materials. Conversely, monitoring for geochemical signals associated with brine leakage exhibited less lateral spread than for scCO2 cases and detection of leakage would be best achieved through monitoring at the base of the interval. Results from these preliminary models for a suite of leakage scenarios and monitoring location distances will be presented. These preliminary models will be

  16. Hierarchical leak detection and localization method in natural gas pipeline monitoring sensor networks.

    Science.gov (United States)

    Wan, Jiangwen; Yu, Yang; Wu, Yinfeng; Feng, Renjian; Yu, Ning

    2012-01-01

    In light of the problems of low recognition efficiency, high false rates and poor localization accuracy in traditional pipeline security detection technology, this paper proposes a type of hierarchical leak detection and localization method for use in natural gas pipeline monitoring sensor networks. In the signal preprocessing phase, original monitoring signals are dealt with by wavelet transform technology to extract the single mode signals as well as characteristic parameters. In the initial recognition phase, a multi-classifier model based on SVM is constructed and characteristic parameters are sent as input vectors to the multi-classifier for initial recognition. In the final decision phase, an improved evidence combination rule is designed to integrate initial recognition results for final decisions. Furthermore, a weighted average localization algorithm based on time difference of arrival is introduced for determining the leak point's position. Experimental results illustrate that this hierarchical pipeline leak detection and localization method could effectively improve the accuracy of the leak point localization and reduce the undetected rate as well as false alarm rate.

  17. 75 FR 4134 - Pipeline Safety: Leak Detection on Hazardous Liquid Pipelines

    Science.gov (United States)

    2010-01-26

    ... safety study on pipeline Supervisory Control and Data Acquisition (SCADA) systems (NTSB/SS-05/02). The... indications of a leak on the SCADA interface was the impetus for this study. The NTSB examined 13 hazardous... large pipeline breaks. The line balance processes incorporating SCADA or other technology are geared...

  18. New methods for leaks detection and localisation using acoustic emission; Nouvelles methodes de detection et de localisation de fuites par emission acoustique

    Energy Technology Data Exchange (ETDEWEB)

    Boulanger, P.

    1993-12-08

    Real time monitoring of Pressurized Water nuclear Reactor secondary coolant system tends to integrate digital processing machines. In this context, the method of acoustic emission seems to exhibit good performances. Its principle is based on passive listening of noises emitted by local micro-displacements inside a material under stress which propagate as elastic waves. The lack of a priori knowledge on leak signals leads us to go deeper into understanding flow induced noise generation. Our studies are conducted using a simple leak model depending on the geometry and the king of flow inside the slit. Detection and localization problems are formulated according to the maximum likelihood principle. For detection, the methods using a indicator of similarity (correlation, higher order correlation) seems to give better results than classical ones (rms value, envelope, filter banks). For leaks location, a large panel of classical (generalized inter-correlation) and innovative (convolution, adaptative, higher order statistics) methods of time delay estimation are presented. The last part deals with the applications of higher order statistics. The analysis of higher order estimators of a non linear non Gaussian stochastic process family, the improvement of non linear prediction performances and the optimal-order choice problem are addressed in simple analytic cases. At last, possible applications to leak signals analysis are pointed out. (authors).264 refs., 7 annexes.

  19. 40 CFR Table 6 to Subpart IIIii of... - Examples of Techniques for Equipment Problem Identification, Leak Detection and Mercury Vapor

    Science.gov (United States)

    2010-07-01

    ...; cracks or spalling in cell room floors, pillars, or beams; caustic leaks; liquid mercury accumulations or... Problem Identification, Leak Detection and Mercury Vapor 6 Table 6 to Subpart IIIII of Part 63 Protection... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt....

  20. SmartPipes: Smart Wireless Sensor Networks for Leak Detection in Water Pipelines

    Directory of Open Access Journals (Sweden)

    Ali M. Sadeghioon

    2014-02-01

    Full Text Available Asset monitoring, specifically infrastructure monitoring such as water distribution pipelines, is becoming increasingly critical for utility owners who face new challenges due to an aging network. In the UK alone, during the period of 2009–2010, approximately 3281 mega litres (106 of water were wasted due to failure or leaks in water pipelines. Various techniques can be used for the monitoring of water distribution networks. This paper presents the design, development and testing of a smart wireless sensor network for leak detection in water pipelines, based on the measurement of relative indirect pressure changes in plastic pipes. Power consumption of the sensor nodes is minimised to 2.2 mW based on one measurement every 6 h in order to prolong the lifetime of the network and increase the sensor nodes’ compatibility with current levels of power available by energy harvesting methods and long life batteries. A novel pressure sensing method is investigated for its performance and capabilities by both laboratory and field trials. The sensors were capable of measuring pressure changes due to leaks. These pressure profiles can also be used to locate the leaks.

  1. 340 Facility Secondary Containment and Leak Detection Project W-302 Functional Design Criteria

    Energy Technology Data Exchange (ETDEWEB)

    Stordeur, R.T.

    1995-03-01

    This functional design criteria for the upgrade to the 340 radioactive liquid waste storage facility (Project W-302) specifically addresses the secondary containment issues at the current vault facility of the 340 Complex. This vault serves as the terminus for the Radioactive Liquid Waste System (RLWS). Project W-302 is necessary in order to bring this portion of the Complex into full regulatory compliance. The project title, ``340 Facility Secondary Containment and Leak Detection``, illustrates preliminary thoughts of taking corrective action directly upon the existing vault (such as removing the tanks, lining the vault, and replacing tanks). However, based on the conclusion of the engineering study, ``Engineering Study of the 300 Area Process Wastewater Handling System``, WHC-SD-WM-ER-277 (as well as numerous follow-up meetings with cognizant staff), this FDC prescribes a complete replacement of the current tank/vault system. This offers a greater array of tanks, and provides greater operating flexibility and ease of maintenance. This approach also minimizes disruption to RLWS services during ``tie-in``, as compared to the alternative of trying to renovate the old vault. The proposed site is within the current Complex area, and maintains the receipt of RLWS solutions through gravity flow.

  2. Compartment Syndrome as a Result of Systemic Capillary Leak Syndrome

    Directory of Open Access Journals (Sweden)

    Kwadwo Kyeremanteng

    2016-01-01

    Full Text Available Objective. To describe a single case of Systemic Capillary Leak Syndrome (SCLS with a rare complication of compartment syndrome. Patient. Our patient is a 57-year-old male, referred to our hospital due to polycythemia (hemoglobin (Hgb of 220 g/L, hypotension, acute renal failure, and bilateral calf pain. Measurements and Main Results. The patient required bilateral forearm, thigh, and calf fasciotomies during his ICU stay and continuous renal replacement therapy was instituted following onset of acute renal failure and oliguria. Ongoing hemodynamic (Norepinephrine and Milrinone infusion and respiratory (ventilator support in the ICU was provided until resolution of intravascular fluid extravasation. Conclusions. SCLS is an extremely rare disorder characterized by unexplained episodic capillary hyperpermeability, which causes shift of volume and protein from the intravascular space to the interstitial space. Patients present with significant hypotension, hemoconcentration, hypovolemia, and oliguria. Severe edema results from leakage of fluid and proteins into tissue. The most important part of treatment is maintaining stable hemodynamics, ruling out other causes of shock and diligent monitoring for complications. Awareness of the clinical syndrome with the rare complication of compartment syndrome may help guide investigations and diagnoses of these critically ill patients.

  3. A Fiber-Optic Sensor for Leak Detection in a Space Environment

    Science.gov (United States)

    Sinko, John E.; Korman, Valentin; Hendrickson, Adam; Polzin, Kurt A.

    2009-01-01

    A miniature fiber-optic, laser-based, interferometric leak detector is presented for application as a means to detect on-orbit gas leaks. The sensor employs a fiber-coupled modified Michelson interferometer to detect gas leaks by measuring an increase in gas density in the sensing region. Monitoring changes in the fringe pattern output by the interferometer allows for direct measurement of the gas density in the sensing region and, under the assumption of an equation of state, this can be used to obtain a pressure measurement. Measurements obtained over a pressure range from 20 mtorr to 760 torr using a prototypical interferometer on working gases of air, nitrogen, argon, and helium generally exhibit agreement with a theoretical prediction of the pressure increase required before an interference fringe completely moves over the detector. Additional measurements performed on various gases demonstrate the range of detectable species, measuring sub-torr pressure changes in the process. A high-fidelity measurement places the ultimate pressure resolution for this particular sensor configuration in the 10 mtorr range. Time-resolved data prove the capability of this sensor to detect fast gas flow phenomena associated with transients and pressure waves.

  4. The International Space Station 2B Photovoltaic Thermal Control System (PVTCS) Leak: An Operational History

    Science.gov (United States)

    Vareha, Anthony N.

    2014-01-01

    As early as 2004, the Photovoltaic Thermal Control System (PVTCS) for the International Space Station's 2B electrical power channel began slowly leaking ammonia overboard. Initially, the operations strategy was "feed the leak," a strategy successfully put into action via Extra Vehicular Activity (EVA) during the STS-134 Space Shuttle mission. This recharge was to have allowed for continued power channel operation into 2014 or 2015, at which point another EVA would have been required. In mid-2012, the leak rate increased from 1.5lbm/year to approximately 5lbm/year. As a result, an EVA was planned and executed within a 5 week timeframe to drastically alter the architecture of the PVTCS via connection to an adjacent dormant thermal control system. This EVA, US EVA 20, was successfully executed on November 1, 2012 and left the 2B PVTCS in a configuration where the system was now being adequately cooled via a different radiator than what the system was designed to utilize. Data monitoring over the next several months showed that the isolated radiator had not been leaking, and the system itself continued to leak steadily until May 9th, 2013. It was on this day that the ISS crew noticed the visible presence of ammonia crystals escaping from the 2B channel's truss segment, signifying a rapid acceleration of the leak from 5lbm/year to 5lbm/day. Within 48 hours of the crew noticing the leak, US EVA 21 was in progress to replace the coolant pump - the only remaining replaceable leak source. This was successful, and telemetry monitoring has shown that indeed the coolant pump was the leak source and was thus isolated from the running 2B PVTCS. This paper will explore the management of the 2B PVTCS leak from the operations perspective.

  5. Infrared Camera System for Visualization of IR-Absorbing Gas Leaks

    Science.gov (United States)

    Youngquist, Robert; Immer, Christopher; Cox, Robert

    2010-01-01

    Leak detection and location remain a common problem in NASA and industry, where gas leaks can create hazardous conditions if not quickly detected and corrected. In order to help rectify this problem, this design equips an infrared (IR) camera with the means to make gas leaks of IR-absorbing gases more visible for leak detection and location. By comparing the output of two IR cameras (or two pictures from the same camera under essentially identical conditions and very closely spaced in time) on a pixel-by-pixel basis, one can cancel out all but the desired variations that correspond to the IR absorption of the gas of interest. This can be simply done by absorbing the IR lines that correspond to the gas of interest from the radiation received by one of the cameras by the intervention of a filter that removes the particular wavelength of interest from the "reference" picture. This can be done most sensitively with a gas filter (filled with the gas of interest) placed in front of the IR detector array, or (less sensitively) by use of a suitable line filter in the same location. This arrangement would then be balanced against the unfiltered "measurement" picture, which will have variations from IR absorption from the gas of interest. By suitable processing of the signals from each pixel in the two IR pictures, the user can display only the differences in the signals. Either a difference or a ratio output of the two signals is feasible. From a gas concentration viewpoint, the ratio could be processed to show the column depth of the gas leak. If a variation in the background IR light intensity is present in the field of view, then large changes in the difference signal will occur for the same gas column concentration between the background and the camera. By ratioing the outputs, the same signal ratio is obtained for both high- and low-background signals, even though the low-signal areas may have greater noise content due to their smaller signal strength. Thus, one

  6. COST AND PERFORMANCE REPORT: INNOVATIVE ACOUSTIC SENSOR TECHNOLOGIES FOR LEAK DETECTION IN CHALLENGING PIPE TYPES

    Science.gov (United States)

    2016-12-30

    Technologies for Leak Detection in Challenging Pipe Types (Cost and Performance Report) Gary Anguiano Edwin Chiang Martha Araujo Stuart Strum Dr. Victor...N3943013C1256 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Gary Anguiano; Edwin Chiang; Martha Araujo; and Stuart Strum (NAVFAC EXWC...Principal Investigator Scott Waisner U.S. Army Engineer R&D Center 3909 Halls Ferry Rd. Vicksburg, MS 39180 (601) 634-2286 (601) 634

  7. Detecting leaks in gas-filled pressure vessels using acoustic resonances

    Science.gov (United States)

    Gillis, K. A.; Moldover, M. R.; Mehl, J. B.

    2016-05-01

    We demonstrate that a leak from a large, unthermostatted pressure vessel into ambient air can be detected an order of magnitude more effectively by measuring the time dependence of the ratio p/f2 than by measuring the ratio p/T. Here f is the resonance frequency of an acoustic mode of the gas inside the pressure vessel, p is the pressure of the gas, and T is the kelvin temperature measured at one point in the gas. In general, the resonance frequencies are determined by a mode-dependent, weighted average of the square of the speed-of-sound throughout the volume of the gas. However, the weighting usually has a weak dependence on likely temperature gradients in the gas inside a large pressure vessel. Using the ratio p/f2, we measured a gas leak (dM/dt)/M ≈ - 1.3 × 10-5 h-1 = - 0.11 yr-1 from a 300-liter pressure vessel filled with argon at 450 kPa that was exposed to sunshine-driven temperature and pressure fluctuations as large as (dT/dt)/T ≈ (dp/dt)/p ≈ 5 × 10-2 h-1 using a 24-hour data record. This leak could not be detected in a 72-hour record of p/T. (Here M is the mass of the gas in the vessel and t is the time.)

  8. Low-cost lightweight airborne laser-based sensors for pipeline leak detection and reporting

    Science.gov (United States)

    Frish, Michael B.; Wainner, Richard T.; Laderer, Matthew C.; Allen, Mark G.; Rutherford, James; Wehnert, Paul; Dey, Sean; Gilchrist, John; Corbi, Ron; Picciaia, Daniele; Andreussi, Paolo; Furry, David

    2013-05-01

    Laser sensing enables aerial detection of natural gas pipeline leaks without need to fly through a hazardous gas plume. This paper describes adaptations of commercial laser-based methane sensing technology that provide relatively low-cost lightweight and battery-powered aerial leak sensors. The underlying technology is near-infrared Standoff Tunable Diode Laser Absorption Spectroscopy (sTDLAS). In one configuration, currently in commercial operation for pipeline surveillance, sTDLAS is combined with automated data reduction, alerting, navigation, and video imagery, integrated into a single-engine single-pilot light fixed-wing aircraft or helicopter platform. In a novel configuration for mapping landfill methane emissions, a miniaturized ultra-lightweight sTDLAS sensor flies aboard a small quad-rotor unmanned aerial vehicle (UAV).

  9. Operational safety and post-maintenance gas leak detection in GE frame 9001FA gas turbines

    Energy Technology Data Exchange (ETDEWEB)

    Farthing, D.A.; Marley, L.; Lees, J.A. [PowerGen plc, Connah' s Quay Power Station, Deeside (United Kingdom)

    1999-12-01

    The increased use of natural-gas-fuelled combined cycle gas turbine and combined heat and power plants in recent years has been accompanied by the practice of constructing acoustic enclosures around the gas turbines for environmental reasons. This can increase the risk of an explosion if, for any reason, there is a build-up of flammable gas within the enclosure, since there can be a range of possible ignition sources. The UK Health and Safety Executive consider gas leaks within such enclosures to be foreseeable, especially following maintenance. The paper presents a review of operational safety and a leak detection method for the inspection and design of flanged joints within the acoustic enclosures around GE 9001FA gas turbines, providing a practical step towards minimising the risk of explosion due to fuel leakage. (Author)

  10. Portable Microleak-Detection System

    Science.gov (United States)

    Rivers, H. Kevin; Sikora, Joseph G.; Sankaran, Sankara N.

    2007-01-01

    The figure schematically depicts a portable microleak-detection system that has been built especially for use in testing hydrogen tanks made of polymer-matrix composite materials. (As used here, microleak signifies a leak that is too small to be detectable by the simple soap-bubble technique.) The system can also be used to test for microleaks in tanks that are made of other materials and that contain gases other than hydrogen. Results of calibration tests have shown that measurement errors are less than 10 percent for leak rates ranging from 0.3 to 200 cm3/min. Like some other microleak-detection systems, this system includes a vacuum pump and associated plumbing for sampling the leaking gas, and a mass spectrometer for analyzing the molecular constituents of the gas. The system includes a flexible vacuum chamber that can be attached to the outer surface of a tank or other object of interest that is to be tested for leakage (hereafter denoted, simply, the test object). The gas used in a test can be the gas or vapor (e.g., hydrogen in the original application) to be contained by the test object. Alternatively, following common practice in leak testing, helium can be used as a test gas. In either case, the mass spectrometer can be used to verify that the gas measured by the system is the test gas rather than a different gas and, hence, that the leak is indeed from the test object.

  11. Microelectromechanical System-Based Internally Unpowered Leak-Pressure Sensor Project

    Data.gov (United States)

    National Aeronautics and Space Administration — To address the NASA need for a miniature pressure-leak sensor, Physical Optics Corporation (POC) proposes to develop a new Microelectromechanical System-based...

  12. Long-wave infrared imaging of vegetation for detecting leaking CO2 gas

    Science.gov (United States)

    Johnson, Jennifer E.; Shaw, Joseph A.; Lawrence, Rick; Nugent, Paul W.; Dobeck, Laura M.; Spangler, Lee H.

    2012-01-01

    The commercial development of uncooled-microbolometer, long-wave infrared (LWIR) imagers, combined with advanced radiometric calibration methods developed at Montana State University, has led to new uses of thermal imagery in remote sensing applications. One specific novel use of these calibrated imagers is imaging of vegetation for CO2 gas leak detection. During a four-week period in the summer of 2011, a CO2 leak was simulated in a test field run by the Zero Emissions Research and Technology Center in Bozeman, Montana. An LWIR imager was deployed on a scaffold before and during the CO2 release, viewing a vegetation test area that included regions of high and low CO2 flux. Increased root-level CO2 concentration caused plant stress that led to reduced thermal regulation of the vegetation, which was consistent with increased diurnal variation of IR emission observed in this study. In a linear regression, the IR data were found to have a strong relationship to the CO2 emission and to be consistent with the location of leaking CO2 gas. Reducing the continuous data set to one image per day weakened the regression fit, but maintained sufficient significance to indicate that this method could be implemented with once-daily airborne images.

  13. Enhanced detection of groundwater contamination from a leaking waste disposal site by microbial community profiles

    Science.gov (United States)

    Mouser, Paula J.; Rizzo, Donna M.; Druschel, Gregory K.; Morales, Sergio E.; Hayden, Nancy; O'Grady, Patrick; Stevens, Lori

    2010-12-01

    Groundwater biogeochemistry is adversely impacted when municipal solid waste leachate, rich in nutrients and anthropogenic compounds, percolates into the subsurface from leaking landfills. Detecting leachate contamination using statistical techniques is challenging because well strategies or analytical techniques may be insufficient for detecting low levels of groundwater contamination. We sampled profiles of the microbial community from monitoring wells surrounding a leaking landfill using terminal restriction fragment length polymorphism (T-RFLP) targeting the 16S rRNA gene. Results show in situ monitoring of bacteria, archaea, and the family Geobacteraceae improves characterization of groundwater quality. Bacterial T-RFLP profiles showed shifts correlated to known gradients of leachate and effectively detected changes along plume fringes that were not detected using hydrochemical data. Experimental sediment microcosms exposed to leachate-contaminated groundwater revealed a shift from a β-Proteobacteria and Actinobacteria dominated community to one dominated by Firmicutes and δ-Proteobacteria. This shift is consistent with the transition from oxic conditions to an anoxic, iron-reducing environment as a result of landfill leachate-derived contaminants and associated redox conditions. We suggest microbial communities are more sensitive than hydrochemistry data for characterizing low levels of groundwater contamination and thus provide a novel source of information for optimizing detection and long-term monitoring strategies at landfill sites.

  14. Development of active acoustic method for water leak detection of LMFBR steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Kumagai, Hiromichi; Yoshida, Kazuo; Kinoshita, Izumi [Central Research Inst. of Electric Power Industry, Tokyo (Japan)

    2001-06-01

    In order to prevent the expansion of tube damage and to maintain structural integrity in the steam generators (SGs) of fast breeder reactors (FBRs), it is necessary to detect precisely and immediately the leakage of water from heat transfer tubes. Therefore, an active acoustic method, which detects the sound attenuation due to bubbles generated in the sodium-water reactions, is being developed. In this study, in order to evaluate the detection sensitivity of the active method, the signal processing methods for emitter and receiver and the detection method for leakage are investigated experimentally. In-water experiments performed by using an SG full-sector model that simulates the actual SGs. As an experimental result, the received sound attenuation for 10s was more than 10dB from air bubble injection when injected bubble of 10 l/s (equivalence water leak rate about 10 g/s.) The attenuation of sound are least affected by bubble injection position of heat transfer tubes bunch department. It is clarified that the background noise hardly influenced water leak detection performance as a result of having examined influence of background noise. (author)

  15. Detecting Methane From Leaking Pipelines and as Greenhouse Gas in the Atmosphere

    Science.gov (United States)

    Riris, Haris; Numata, Kenji; Li, Steven; Wu, Stewart; Ramanathan, Anand; Dawsey, Martha

    2012-01-01

    Laser remote sensing measurements of trace gases from orbit can provide unprecedented information about important planetary science and answer critical questions about planetary atmospheres. Methane (CH4) is the second most important anthropogenically produced greenhouse gas. Though its atmospheric abundance is much less than that of CO2 (1.78 ppm vs. 380 ppm), it has much larger greenhouse heating potential. CH4 also contributes to pollution in the lower atmosphere through chemical reactions, leading to ozone production. Atmospheric CH4 concentrations have been increasing as a result of increased fossil fuel production, rice farming, livestock, and landfills. Natural sources of CH4 include wetlands, wild fires, and termites, and perhaps other unknown sources. Important sinks for CH4 include non-saturated soils and oxidation by hydroxyl radicals in the atmosphere. Remotely measuring CH4 and other biogenic molecules (such as ethane and formaldehyde) on Mars also has important implications on the existence of life on Mars. Measuring CH4 at very low (ppb) concentrations from orbit will dramatically improve the sensitivity and spatial resolution in the search for CH4 vents and sub-surface life on other planets. A capability has been developed using lasers and spectroscopic detection techniques for the remote measurements of trace gases in open paths. Detection of CH4, CO2, H2O, and CO in absorption cells and in open paths, both in the mid- IR and near-IR region, has been demonstrated using an Optical Parametric Amplifier laser transmitter developed at GSFC. With this transmitter, it would be possible to develop a remote sensing methane instrument. CH4 detection also has very important commercial applications. Pipeline leak detection from an aircraft or a helicopter can significantly reduce cost, response time, and pinpoint the location. The main advantage is the ability to rapidly detect CH4 leaks remotely. This is extremely important for the petrochemical industry

  16. A case of spontaneous cerebrospinal fluid rhinorrhea: Accurate detection of the leak point by magnetic resonance cisternography

    Directory of Open Access Journals (Sweden)

    Teppei Matsubara

    2014-01-01

    Full Text Available Background: Spontaneous cerebrospinal fluid (CSF rhinorrhea is a rare entity. The accurate preoperative localization of the leak point is essential for planning surgical treatment, but is sometimes difficult. To localize the leak point, magnetic resonance cisternography (MRC is the method of choice, but its effectiveness remains unclear. Case Description: A 34-year-old mildly obese female experienced spontaneous CSF rhinorrhea after an attack of bronchial asthma. High-resolution computed tomography (CT failed to reveal the leak point, while MRC demonstrated an arachnoid herniation at the olfactory cleft. The patient underwent endoscopic endonasal repair of the CSF leak with success. There has been no recurrence of CSF rhinorrhea for 14 months after surgery followed by the administration of acetazolamide. Conclusion: We report a rare case of spontaneous CSF rhinorrhea associated with benign intracranial hypertension, in which the leak point was successfully detected by MRC. The CSF leak was completely repaired by minimally invasive endoscopic endonasal surgery. MRC may be a reliable method for detecting CSF leak points.

  17. Detection of active bile leak with Gd-EOB-DTPA enhanced MR cholangiography: Comparison of 20–25 min delayed and 60–180 min delayed images

    Energy Technology Data Exchange (ETDEWEB)

    Cieszanowski, Andrzej, E-mail: andrzej.cieszanowski@wum.edu.pl [2nd Department of Clinical Radiology, Medical University of Warsaw, ul. Banacha 1A, 02-097 Warszawa (Poland); Stadnik, Anna, E-mail: aniaws@yahoo.com [2nd Department of Clinical Radiology, Medical University of Warsaw, ul. Banacha 1A, 02-097 Warszawa (Poland); Lezak, Aleksandra, E-mail: aleksandralezak@gmail.com [2nd Department of Clinical Radiology, Medical University of Warsaw, ul. Banacha 1A, 02-097 Warszawa (Poland); Maj, Edyta, E-mail: em26@wp.pl [2nd Department of Clinical Radiology, Medical University of Warsaw, ul. Banacha 1A, 02-097 Warszawa (Poland); Zieniewicz, Krzysztof, E-mail: krzysztof.zieniewicz@wum.edu.pl [Chair and Department of General, Transplant and Liver Surgery, Medical University of Warsaw, ul. Banacha 1A, 02-097 Warszawa (Poland); Rowinska-Berman, Katarzyna, E-mail: kasiarowinska@wp.pl [2nd Department of Clinical Radiology, Medical University of Warsaw, ul. Banacha 1A, 02-097 Warszawa (Poland); Grudzinski, Ireneusz P., E-mail: ireneusz.grudzinski@wum.edu.pl [Department of Toxicology, Medical University of Warsaw, Faculty of Pharmacy, ul. Banacha 1, 02-097 Warsaw (Poland); Krawczyk, Marek, E-mail: marek.krawczyk@wum.edu.pl [Chair and Department of General, Transplant and Liver Surgery, Medical University of Warsaw, ul. Banacha 1A, 02-097 Warszawa (Poland); Rowiński, Olgierd, E-mail: olgierd.rowinski@wum.edu.pl [2nd Department of Clinical Radiology, Medical University of Warsaw, ul. Banacha 1A, 02-097 Warszawa (Poland)

    2013-12-01

    Objectives: The purpose of this study was to assess the value of contrast-enhanced magnetic resonance cholangiography (MRC) performed in different time delays after injection of gadoxetic acid disodium (Gd-EOB-DTPA) for the diagnosis of active bile leak. Methods: This retrospective analysis included Gd-EOB-DTPA enhanced MR images of 34 patients suspected of bile leak. Images were acquired 20–25 min after Gd-EOB-DTPA injection. If there was inadequate contrast in the bile ducts then delayed images after 60–90 min and 150–180 min were obtained. Results were correlated with intraoperative findings, ERCP results, clinical data, laboratory tests, and follow-up examinations. Results: Gd-EOB-DTPA enhanced MRC yielded an overall sensitivity of 96.4%, specificity of 100% and accuracy of 97.1% for the diagnosis of an active bile leak. The sensitivity of 20–25 min delayed MR images was 42.9%, of combined 20–25 min and 60–90 min delayed images was 92.9% and of combined 20–25 min, 60–90 min and 150–180 min delayed images was 96.4%. Conclusions: Gd-EOB-DTPA enhanced MRC utilizing delayed phase images was effective for detecting the presence and location of active bile leaks. The images acquired 60–180 min post-injection enabled identification of bile leaks even in patients with a dilated biliary system or moderate liver dysfunction.

  18. Results of Tank-Leak Detection Demonstration Using Geophysical Techniques at the Hanford Mock Tank Site-Fiscal Year 2001

    Energy Technology Data Exchange (ETDEWEB)

    Barnett, D BRENT.; Gee, Glendon W.; Sweeney, Mark D.

    2002-03-01

    During July and August of 2001, Pacific Northwest National Laboratory (PNNL), hosted researchers from Lawrence Livermore and Lawrence Berkeley National laboratories, and a private contractor, HydroGEOPHYSICS, Inc., for deployment of the following five geophysical leak-detection technologies at the Hanford Site Mock Tank in a Tank Leak Detection Demonstration (TLDD): (1) Electrical Resistivity Tomography (ERT); (2) Cross-Borehole Electromagnetic Induction (CEMI); (3) High-Resolution Resistivity (HRR); (4) Cross-Borehole Radar (XBR); and (5) Cross-Borehole Seismic Tomography (XBS). Under a ''Tri-party Agreement'' with Federal and state regulators, the U.S. Department of Energy will remove wastes from single-shell tanks (SSTs) and other miscellaneous underground tanks for storage in the double-shell tank system. Waste retrieval methods are being considered that use very little, if any, liquid to dislodge, mobilize, and remove the wastes. As additional assurance of protection of the vadose zone beneath the SSTs, tank wastes and tank conditions may be aggressively monitored during retrieval operations by methods that are deployed outside the SSTs in the vadose zone.

  19. Semi-empirical AGN detection threshold in spectral synthesis studies of Lyman-continuum-leaking early-type galaxies

    CERN Document Server

    Cardoso, Leandro S M; Papaderos, Polychronis

    2016-01-01

    Various lines of evidence suggest that the cores of a large portion of early-type galaxies (ETGs) are virtually evacuated of warm ionised gas. This implies that the Lyman-continuum (LyC) radiation produced by an assumed active galactic nucleus (AGN) can escape from the nuclei of these systems without being locally reprocessed into nebular emission, which would prevent their reliable spectroscopic classification as Seyfert galaxies with standard diagnostic emission-line ratios. The spectral energy distribution (SED) of these ETGs would then lack nebular emission and be essentially composed of an old stellar component and the featureless power-law (PL) continuum from the AGN. A question that arises in this context is whether the AGN component can be detected with current spectral population synthesis in the optical, specifically, whether these techniques effectively place an AGN detection threshold in LyC-leaking galaxies. To quantitatively address this question, we took a combined approach that involves spectr...

  20. 1.6 Micron Fiber Laser Source for CH4 Gas Leak Detection

    Directory of Open Access Journals (Sweden)

    Cézard Nicolas

    2016-01-01

    Full Text Available We report on the development of a new pulsed fiber laser source at 1645.5 nm, based on stimulated Raman amplification. This laser source is intended to be used in a future lidar system, dedicated to methane gas leak monitoring in the vicinity of industrial facilities. In this paper we discuss reasons for choosing the 1645.5 nm wavelength, and then we present the two-stage amplification architecture of our fiber laser source under development. Recent experimental results are provided and perspectives are drawn.

  1. Performance evaluation of PFBR wire type sodium leak detectors

    Energy Technology Data Exchange (ETDEWEB)

    Vijayakumar, G., E-mail: viju@igcar.gov.in [Fast Reactor Technology Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603102 (India); Rajan, K.K.; Nashine, B.K.; Chandramouli, S. [Fast Reactor Technology Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603102 (India); Madhusoodanan, K. [Reactor Engineering Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603102 (India); Kalyanasundaram, P. [Fast Reactor Technology Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603102 (India)

    2011-06-15

    , performance requirement of leak detection system as per codes, description of test facility, experimental procedure, test results of various experiments conducted and details of measurements made on contact resistance of detector after sodium leak. Paper also reviews the experiment conducted in CEA, Cadrache and compares with results of present experimental study.

  2. Design of an Infrared Imaging System for Robotic Inspection of Gas Leaks in Industrial Environments

    Directory of Open Access Journals (Sweden)

    Miguel A. Rodriguez-Conejo

    2015-03-01

    The mobile platform where the gas sensing system is going to be implemented is a robot called TurtleBot. The control of the mobile base and of the inspection device is integrated in ROS architecture. The exploration system is based on the technique of Simultaneous Localization and Mapping (SLAM that makes it possible to locate the gas leak in the map.

  3. Closeup of STS-26 Discovery, OV-103, orbital maneuvering system (OMS) leak

    Science.gov (United States)

    1988-01-01

    Closeup of STS-26 Discovery, Orbiter Vehicle (OV) 103, orbital maneuvering system (OMS) reaction control system (RCS) nitrogen tetroxide gas leak was captured by a Cobra borescope and displayed on a video monitor. The borescope has a miniature videocamera at the end of a flexible rubber tube and is able to be maneuvered into other inaccessible locations.

  4. LIBS Sensor for Sub-surface CO2 Leak Detection in Carbon Sequestration

    Directory of Open Access Journals (Sweden)

    Jinesh JAIN

    2017-07-01

    Full Text Available Monitoring carbon sequestration poses numerous challenges to the sensor community. For example, the subsurface environment is notoriously harsh, with large potential mechanical, thermal, and chemical stresses, making long-term stability and survival a challenge to any potential in situ monitoring method. Laser induced breakdown spectroscopy (LIBS has been demonstrated as a promising technology for chemical monitoring of harsh environments and hard to reach places. LIBS has a real- time monitoring capability and can be used for the elemental and isotopic analysis of solid, liquid, and gas samples. The flexibility of the probe design and the use of fiber- optics has made LIBS particularly suited for remote measurements. The paper focuses on developing a LIBS instrument for downhole high-pressure, high-temperature brine experiments, where CO2 leakage could result in changes in the trace mineral composition of an aquifer. The progress in fabricating a compact, robust, and simple LIBS sensor for widespread subsurface leak detection is presented.

  5. Passive acoustic leak detection for sodium cooled fast reactors using hidden Markov models

    Energy Technology Data Exchange (ETDEWEB)

    Riber Marklund, A. [CEA, Cadarache, DEN/DTN/STCP/LIET, Batiment 202, 13108 St Paul-lez-Durance, (France); Kishore, S. [Fast Reactor Technology Group of IGCAR, (India); Prakash, V. [Vibrations Diagnostics Division, Fast Reactor Technology Group of IGCAR, (India); Rajan, K.K. [Fast Reactor Technology Group and Engineering Services Group of IGCAR, (India)

    2015-07-01

    Acoustic leak detection for steam generators of sodium fast reactors have been an active research topic since the early 1970's and several methods have been tested over the years. Inspired by its success in the field of automatic speech recognition, we here apply hidden Markov models (HMM) in combination with Gaussian mixture models (GMM) to the problem. To achieve this, we propose a new feature calculation scheme, based on the temporal evolution of the power spectral density (PSD) of the signal. Using acoustic signals recorded during steam/water injection experiments done at the Indira Gandhi Centre for Atomic Research (IGCAR), the proposed method is tested. We perform parametric studies on the HMM+GMM model size and demonstrate that the proposed method a) performs well without a priori knowledge of injection noise, b) can incorporate several noise models and c) has an output distribution that simplifies false alarm rate control. (authors)

  6. Leak before break evaluation for main steam piping system made of SA106 Gr.C

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Kyoung Mo; Jee, Kye Kwang; Pyo, Chang Ryul; Ra, In Sik [Korea Power Engineering Company, Seoul (Korea, Republic of)

    1997-04-01

    The basis of the leak before break (LBB) concept is to demonstrate that piping will leak significantly before a double ended guillotine break (DEGB) occurs. This is demonstrated by quantifying and evaluating the leak process and prescribing safe shutdown of the plant on the basis of the monitored leak rate. The application of LBB for power plant design has reduced plant cost while improving plant integrity. Several evaluations employing LBB analysis on system piping based on DEGB design have been completed. However, the application of LBB on main steam (MS) piping, which is LBB applicable piping, has not been performed due to several uncertainties associated with occurrence of steam hammer and dynamic strain aging (DSA). The objective of this paper is to demonstrate the applicability of the LBB design concept to main steam lines manufactured with SA106 Gr.C carbon steel. Based on the material properties, including fracture toughness and tensile properties obtained from the comprehensive material tests for base and weld metals, a parametric study was performed as described in this paper. The PICEP code was used to determine leak size crack (LSC) and the FLET code was used to perform the stability assessment of MS piping. The effects of material properties obtained from tests were evaluated to determine the LBB applicability for the MS piping. It can be shown from this parametric study that the MS piping has a high possibility of design using LBB analysis.

  7. Air Conditioning Compressor Air Leak Detection by Image Processing Techniques for Industrial Applications

    Directory of Open Access Journals (Sweden)

    Pookongchai Kritsada

    2015-01-01

    Full Text Available This paper presents method to detect air leakage of an air conditioning compressor using image processing techniques. Quality of air conditioning compressor should not have air leakage. To test an air conditioning compressor leak, air is pumped into a compressor and then submerged into the water tank. If air bubble occurs at surface of the air conditioning compressor, that leakage compressor must be returned for maintenance. In this work a new method to detect leakage and search leakage point with high accuracy, fast, and precise processes was proposed. In a preprocessing procedure to detect the air bubbles, threshold and median filter techniques have been used. Connected component labeling technique is used to detect the air bubbles while blob analysis is searching technique to analyze group of the air bubbles in sequential images. The experiments are tested with proposed algorithm to determine the leakage point of an air conditioning compressor. The location of the leakage point was presented as coordinated point. The results demonstrated that leakage point during process could be accurately detected. The estimation point had error less than 5% compared to the real leakage point.

  8. Portable Dual-comb Spectrometer for Stable Detection of Methane Leaks over Kilometer Scale Paths at Oil and Natural Gas Production Site

    Science.gov (United States)

    Coburn, S.; Wright, R.; Cossel, K.; Truong, G. W.; Baumann, E.; Coddington, I.; Newbury, N.; Alden, C. B.; Ghosh, S.; Prasad, K.; Rieker, G. B.

    2016-12-01

    Newly proposed EPA regulations on volatile organic compound (VOC) emissions from oil and gas production facilities have been expanded to include methane, making the detection of this important trace gas a topic of growing interest to the oil and gas industry, regulators, and the scientific community in general. Reliable techniques that enable long-term monitoring of entire production facilities are needed in order to fully characterize the temporal and spatial trends of emissions from these sites. Recent advances in the development of compact and robust fiber frequency combs are enabling the use of this powerful spectroscopic tool outside of the laboratory, presenting opportunities for kilometer-scale open-path sensing of emissions at remote locations. Here we present the characterization and field deployment of a dual comb spectrometer (DCS) system with the potential to locate and size methane leaks from oil and gas production sites from long range. The DCS is a laser-based system that enables broad spectral absorption measurements (>50 nm) with high spectral resolution (locations near Boulder, CO, demonstrating sensitivities of better than 2 ppb-km for methane. In addition, path integrated methane measurements from the DCS are coupled with an atmospheric inversion utilizing local meteorology and a high resolution fluid dynamics simulation to determine leak location and also derive a leak rate from simulated methane leaks

  9. 40 CFR 264.196 - Response to leaks or spills and disposition of leaking or unfit-for-use tank systems.

    Science.gov (United States)

    2010-07-01

    ... HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Tank Systems § 264.196 Response to leaks or... flow or addition of wastes. The owner or operator must immediately stop the flow of hazardous waste... much of the waste as is necessary to prevent further release of hazardous waste to the environment and...

  10. Research overview of real-time monitoring system for micro leak of three-dimensional pipe network

    Directory of Open Access Journals (Sweden)

    Shaofeng WANG

    2016-04-01

    Full Text Available Aiming at the key technical problems encountered by domestic and foreign scholars in building the real-time monitoring system for the micro leak of three-dimensional pipe networks, the paper classifies the problems into three aspects: 1 in the extraction of fault signal frequency, how to avoid the effect of the mixed echo stack and improve the delay estimation accuracy of the correlation; 2 in network bifurcation structure, how to discern the signal propagation path, and how to locate the leak source; 3 under the uncertainly delay in transmitting and receiving information data, how to ensure the time synchronization accuracy of the real-time monitoring system for the three-dimensional pipe network leakage. Through the comparison of the monitoring technologies for the pipe network leakage at home and abroad, it shows that the acoustic emission sensor network based three-dimensional pipeline leak real-time monitoring has great advantages in detecting the weak leakage of flammable and explosive gas/liquid transportation pipelines.

  11. Visual detection of gas shows from coal core and cuttings using liquid leak detector

    Energy Technology Data Exchange (ETDEWEB)

    Barker, C.E. [United States Geological Survey, Denver, CO (United States)

    2006-09-15

    Coal core descriptions are difficult to obtain, as they must be obtained immediately after the core is retrieved and before the core is closed in a canister. This paper described a method of marking gas shows on a core surface by coating the core with a water-based liquid leak detector and photographing the subsequent foam developed on the core surface while the core is still in the core tray. Coals from a borehole at the Yukon Flats Basin in Alaska and the Maverick Basin in Texas were used to illustrate the method. Drilling mud and debris were removed from the coal samples before the leak detector solution was applied onto the core surfaces. A white froth or dripping foam developed rapidly at gas shows on the sample surfaces. A hand-held lens and a binocular microscope were used to magnify the foaming action. It was noted that foaming was not continuous across the core surface, but was restricted to localized points along the surface. It was suggested that the localized point foaming may have resulted from the coring process. However, the same tendency toward point gas show across the sample surface was found in some hard, well-indurated samples that still had undisturbed bedding and other sedimentary structures. It was concluded that gas shows marked as separate foam centres may indicate a real condition of local permeability paths. Results suggested that the new gas show detection method could be used in core selection studies to reduce the costs of exploration programs. 6 refs., 4 figs.

  12. Method and system for capturing hydrocarbons from a leaking oilwell at a predetermined seabed location

    NARCIS (Netherlands)

    Van Nauta Lemke, A.H.A.; Willemse, C.A.

    2013-01-01

    Method and system for capturing hydrocarbons from a leaking oilwell at a predetermined seabed location, in which the steps are applied of: a. deploying a dome near the predetermined seabed location; b. moving the dome to the predetermined seabed location; c. capturing the hydrocarbons from the leaki

  13. FIELD DEMONSTRATION OF INNOVATIVE LEAK DETECTION/LOCATION TECHNOLOGIES COUPLED WITH WALL-THICKNESS SCREENING FOR WATER MAINS

    Science.gov (United States)

    The U.S. Environmental Protection Agency sponsored a large-scale field demonstration of innovative leak detection/location and condition assessment technologies on a 76-year old, 2,500-ft long, cement-lined, 24-in. cast iron water main in Louisville, KY from July through Septembe...

  14. Highly precise atmospheric oxygen measurements as a tool to detect leaks of carbon dioxide from Carbon Capture and Storage sites

    NARCIS (Netherlands)

    van Leeuwen, Charlotte

    2015-01-01

    In Carbon Capture and Storage (CCS), carbon dioxide (CO2) from fossil fuel combustion is stored underground into a geological formation. Although the storage of CO2 is considered as safe, leakage to the atmosphere is an important concern and monitoring is necessary. Detecting and quantifying leaks o

  15. Highly precise atmospheric oxygen measurements as a tool to detect leaks of carbon dioxide from Carbon Capture and Storage sites

    NARCIS (Netherlands)

    van Leeuwen, Charlotte

    2015-01-01

    In Carbon Capture and Storage (CCS), carbon dioxide (CO2) from fossil fuel combustion is stored underground into a geological formation. Although the storage of CO2 is considered as safe, leakage to the atmosphere is an important concern and monitoring is necessary. Detecting and quantifying leaks o

  16. Highly precise atmospheric oxygen measurements as a tool to detect leaks of carbon dioxide from Carbon Capture and Storage sites

    NARCIS (Netherlands)

    van Leeuwen, Charlotte

    2015-01-01

    In Carbon Capture and Storage (CCS), carbon dioxide (CO2) from fossil fuel combustion is stored underground into a geological formation. Although the storage of CO2 is considered as safe, leakage to the atmosphere is an important concern and monitoring is necessary. Detecting and quantifying leaks

  17. Fugitive methane emissions from leak-prone natural gas distribution infrastructure in urban environments.

    Science.gov (United States)

    Hendrick, Margaret F; Ackley, Robert; Sanaie-Movahed, Bahare; Tang, Xiaojing; Phillips, Nathan G

    2016-06-01

    Fugitive emissions from natural gas systems are the largest anthropogenic source of the greenhouse gas methane (CH4) in the U.S. and contribute to the risk of explosions in urban environments. Here, we report on a survey of CH4 emissions from 100 natural gas leaks in cast iron distribution mains in Metro Boston, MA. Direct measures of CH4 flux from individual leaks ranged from 4.0 - 2.3 × 10(4) g CH4•day(-1). The distribution of leak size is positively skewed, with 7% of leaks contributing 50% of total CH4 emissions measured. We identify parallels in the skewed distribution of leak size found in downstream systems with midstream and upstream stages of the gas process chain. Fixing 'superemitter' leaks will disproportionately stem greenhouse gas emissions. Fifteen percent of leaks surveyed qualified as potentially explosive (Grade 1), and we found no difference in CH4 flux between Grade 1 leaks and all remaining leaks surveyed (p = 0.24). All leaks must be addressed, as even small leaks cannot be disregarded as 'safely leaking.' Key methodological impediments to quantifying and addressing the impacts of leaking natural gas distribution infrastructure involve inconsistencies in the manner in which gas leaks are defined, detected, and classified. To address this need, we propose a two-part leak classification system that reflects both the safety and climatic impacts of natural gas leaks.

  18. NRC Job Code V6060: Extended in-situ and real time monitoring. Task 4: Detection and monitoring of leaks at nuclear power plants external to structures

    Energy Technology Data Exchange (ETDEWEB)

    Sheen, S. H. (Nuclear Engineering Division)

    2012-08-01

    In support of Task 4 of the NRC study on compliance with 10 CFR part 20.1406, minimization of contamination, Argonne National Laboratory (ANL) conducted a one-year scoping study, in concert with a parallel study performed by NRC/NRR staff, on monitoring for leaks at nuclear power plants (NPPs) external to structures. The objective of this task-4 study is to identify and assess those sensors and monitoring techniques for early detection of abnormal radioactive releases from the engineered facility structures, systems and components (SSCs) to the surrounding underground environment in existing NPPs and planned new reactors. As such, methods of interest include: (1) detection of anomalous water content of soils surrounding SSCs, (2) radionuclides contained in the leaking water, and (3) secondary signals such as temperature. ANL work scope includes mainly to (1) identify, in concert with the nuclear industry, the sensors and techniques that have most promise to detect radionuclides and/or associated chemical releases from SSCs of existing NPPs and (2) review and provide comments on the results of the NRC/NRR staff scoping study to identify candidate technologies. This report constitutes the ANL deliverable of the task-4 study. It covers a survey of sensor technologies and leak detection methods currently applied to leak monitoring at NPPs. The survey also provides a technology evaluation that identifies their strength and deficiency based on their detection speed, sensitivity, range and reliability. Emerging advanced technologies that are potentially capable of locating releases, identifying the radionuclides, and estimating their concentrations and distributions are also included in the report along with suggestions of required further research and development.

  19. Doppler method leak detection for LMFBR steam generators. Pt. 1. Experimental results of bubble detection using small models

    Energy Technology Data Exchange (ETDEWEB)

    Kumagai, Hiromichi [Central Research Inst. of Electric Power Industry, Komae, Tokyo (Japan). Komae Research Lab

    1999-05-01

    To prevent the expansion of the tube damage and to maintain structural integrity in the steam generators (SGs) of fast breeder reactors (FBRs), it is necessary to detect precisely and immediately the leakage of water from heat transfer tubes. Therefore, an active acoustic method was developed. Previous studies have revealed that in practical steam generators the active acoustic method can detect bubbles of 10 l/s within 10 seconds. To prevent the expansion of damage to neighboring tubes, it is necessary to detect smaller leakages of water from the heat transfer tubes. The Doppler method is designed to detect small leakages and to find the source of the leak before damage spreads to neighboring tubes. To evaluate the relationship between the detection sensitivity of the Doppler method and the bubble volume and bubble size, the structural shapes and bubble flow conditions were investigated experimentally, using a small structural model. The results show that the Doppler method can detect the bubbles under bubble flow conditions, and it is sensitive enough to detect small leakages within a short time. The doppler method thus has strong potential for the detection of water leakage in SGs. (author)

  20. A Novel Feature Extraction Method for Monitoring (Vehicular) Fuel Storage System Leaks

    Science.gov (United States)

    2014-10-02

    optimization) based learning methods. Leak detection mechanism as part of an overall emission control strategy is gaining importance in recent...fundamentally different way of extracting information from the in-tank pressure signal stream as it is one of most critical parts of an overall redesign...signal procesing methods such as signal smoothing, clipping and flipping. Other common modifications may also include multiple scalers associated with

  1. Sensitivity and specificity of intrathecal fluorescein and white light excitation for detecting intraoperative cerebrospinal fluid leak in endoscopic skull base surgery: a prospective study.

    Science.gov (United States)

    Raza, Shaan M; Banu, Matei A; Donaldson, Angela; Patel, Kunal S; Anand, Vijay K; Schwartz, Theodore H

    2016-03-01

    The intraoperative detection of CSF leaks during endonasal endoscopic skull base surgery is critical to preventing postoperative CSF leaks. Intrathecal fluorescein (ITF) has been used at varying doses to aid in the detection of intraoperative CSF leaks. However, the sensitivity and specificity of ITF at certain dosages is unknown. A prospective database of all endoscopic endonasal procedures was reviewed. All patients received 25 mg ITF diluted in 10 ml CSF and were pretreated with dexamethasone and Benadryl. Immediately after surgery, the operating surgeon prospectively noted if there was an intraoperative CSF leak and fluorescein was identified. The sensitivity, specificity, and positive and negative predictive power of ITF for detecting intraoperative CSF leak were calculated. Factors correlating with postoperative CSF leak were determined. Of 419 patients, 35.8% of patients did not show a CSF leak. Fluorescein-tinted CSF (true positive) was noted in 59.7% of patients and 0 false positives were encountered. CSF without fluorescein staining (false negative) was noted in 4.5% of patients. The sensitivity and specificity of ITF were 92.9% and 100%, respectively. The negative and positive predictive values were 88.8% and 100%, respectively. Postoperative CSF leaks only occurred in true positives at a rate of 2.8%. ITF is extremely specific and very sensitive for detecting intraoperative CSF leaks. Although false negatives can occur, these patients do not appear to be at risk for postoperative CSF leak. The use of ITF may help surgeons prevent postoperative CSF leaks by intraoperatively detecting and confirming a watertight repair.

  2. ISS Leak Detection and Astrophysics with Lobster-Eye X-Ray Detector Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Demonstrate angular resolution and sensitivity. Successful lab demonstration of ISS leak checking, using nitrogen, electron beam, and Lobster x-ray optic. 

  3. AIRBORNE, OPTICAL REMOTE SENSING OF METHANE AND ETHANE FOR NATURAL GAS PIPLINE LEAK DETECTION

    Energy Technology Data Exchange (ETDEWEB)

    Jerry Myers

    2004-05-12

    Ophir Corporation was awarded a contract by the U. S. Department of Energy, National Energy Technology Laboratory under the Project Title ''Airborne, Optical Remote Sensing of Methane and Ethane for Natural Gas Pipeline Leak Detection'' on October 14, 2002. The third six-month technical report contains a summary of the progress made towards finalizing the design and assembling the airborne, remote methane and ethane sensor. The vendor has been chosen and is on contract to develop the light source with the appropriate linewidth and spectral shape to best utilize the Ophir gas correlation software. Ophir has expanded upon the target reflectance testing begun in the previous performance period by replacing the experimental receiving optics with the proposed airborne large aperture telescope, which is theoretically capable of capturing many times more signal return. The data gathered from these tests has shown the importance of optimizing the fiber optic receiving fiber to the receiving optic and has helped Ophir to optimize the design of the gas cells and narrowband optical filters. Finally, Ophir will discuss remaining project issues that may impact the success of the project.

  4. AIRBORNE, OPTICAL REMOTE SENSING OF METHANE AND ETHANE FOR NATURAL GAS PIPELINE LEAK DETECTION

    Energy Technology Data Exchange (ETDEWEB)

    Jerry Myers

    2003-11-12

    Ophir Corporation was awarded a contract by the U. S. Department of Energy, National Energy Technology Laboratory under the Project Title ''Airborne, Optical Remote Sensing of Methane and Ethane for Natural Gas Pipeline Leak Detection'' on October 14, 2002. This second six-month technical report summarizes the progress made towards defining, designing, and developing the hardware and software segments of the airborne, optical remote methane and ethane sensor. The most challenging task to date has been to identify a vendor capable of designing and developing a light source with the appropriate output wavelength and power. This report will document the work that has been done to identify design requirements, and potential vendors for the light source. Significant progress has also been made in characterizing the amount of light return available from a remote target at various distances from the light source. A great deal of time has been spent conducting laboratory and long-optical path target reflectance measurements. This is important since it helps to establish the overall optical output requirements for the sensor. It also reduces the relative uncertainty and risk associated with developing a custom light source. The data gathered from the optical path testing has been translated to the airborne transceiver design in such areas as: fiber coupling, optical detector selection, gas filters, and software analysis. Ophir will next, summarize the design progress of the transceiver hardware and software development. Finally, Ophir will discuss remaining project issues that may impact the success of the project.

  5. 40 CFR 63.1024 - Leak repair.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Leak repair. 63.1024 Section 63.1024... Standards for Equipment Leaks-Control Level 2 Standards § 63.1024 Leak repair. (a) Leak repair schedule. The owner or operator shall repair each leak detected as soon as practical, but not later than 15...

  6. 40 CFR 65.105 - Leak repair.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Leak repair. 65.105 Section 65.105... FEDERAL AIR RULE Equipment Leaks § 65.105 Leak repair. (a) Leak repair schedule. The owner or operator shall repair each leak detected as soon as practical but not later than 15 calendar days after it...

  7. Privacy Leaks through Data Hijacking Attack on Mobile Systems

    Directory of Open Access Journals (Sweden)

    Zhang Daojuan

    2017-01-01

    Full Text Available To persistently eavesdrop on the mobile devices, attackers may obtain the elevated privilege and inject malicious modules into the user devices. Unfortunately, the attackers may not be able to obtain the privilege for a long period of time since the exploitable vulnerabilities may be fixed or the malware may be removed. In this paper, we propose a new data hijacking attack for the mobile apps. By employing the proposed method, the attackers are only required to obtain the root privilege of the user devices once, and they can persistently eavesdrop without any change to the original device. Specifically, we design a new approach to construct a shadow system by hijacking user data files. In the shadow system, attackers possess the identical abilities to the victims. For instance, if a victim has logged into the email app, the attacker can also access the email server in the shadow system without authentication in a long period of time. Without reauthentication of the app, it is difficult for victims to notice the intrusion since the whole eavesdropping is performed on other devices (rather than the user devices. In our experiments, we evaluate the effectiveness of the proposed attack and the result demonstrates that even the Android apps released by the top developers cannot resist this attack. Finally, we discuss some approaches to defend the proposed attack.

  8. Emergency membrane contactor based absorption system for ammonia leaks in water treatment plants

    Institute of Scientific and Technical Information of China (English)

    SHAO Jiahui; FANG Xuliang; HE Yiliang; JIN Qiang

    2008-01-01

    Because of the suspected health risks of trihalomethanes (THMs), more and more water treatment plants have replaced traditionalchlorine disinfection process with chloramines but often without the proper absorption system installed in the case of ammonia leaksin the storage room. A pilot plant membrane absorption system was developed and installed in a water treatment plant for this purpose.Experimentally determined contact angle, surface tension, and corrosion tests indicated that the sulfuric acid was the proper choice as the absorbent for leaking ammonia using polypropylene hollow fiber membrane contactor. Effects of several operating conditionson the mass transfer coefficient, ammonia absorption, and removal efficiency were examined, including the liquid concentration,liquid velocity, and feed gas concentration. Under the operation conditions investigated, the gas absorption efficiency over 99.9%was achieved. This indicated that the designed pilot plant membrane absorption system was effective to absorb the leaking ammonia in the model storage room. The removal rate of the ammonia in the model storage room was also experimentally and theoretically foundto be primarily determined by the ammonia suction flow rate from the ammonia storage room to the membrane contactor. The ammoniaremoval rate of 99.9% was expected to be achieved within 1.3 h at the ammonia gas flow rate of 500 m3/h. The success of the pilot plantmembrane absorption system developed in this study illustrated the potential of this technology for ammonia leaks in water treatmentplant, also paved the way towards a larger scale application.

  9. AIRBORNE, OPTICAL REMOTE SENSING OF METHANE AND ETHANE FOR NATURAL GAS PIPELINE LEAK DETECTION

    Energy Technology Data Exchange (ETDEWEB)

    Jerry Myers

    2003-05-13

    Ophir Corporation was awarded a contract by the U. S. Department of Energy, National Energy Technology Laboratory under the Project Title ''Airborne, Optical Remote Sensing of Methane and Ethane for Natural Gas Pipeline Leak Detection'' on October 14, 2002. This six-month technical report summarizes the progress for each of the proposed tasks, discusses project concerns, and outlines near-term goals. Ophir has completed a data survey of two major natural gas pipeline companies on the design requirements for an airborne, optical remote sensor. The results of this survey are disclosed in this report. A substantial amount of time was spent on modeling the expected optical signal at the receiver at different absorption wavelengths, and determining the impact of noise sources such as solar background, signal shot noise, and electronic noise on methane and ethane gas detection. Based upon the signal to noise modeling and industry input, Ophir finalized the design requirements for the airborne sensor, and released the critical sensor light source design requirements to qualified vendors. Responses from the vendors indicated that the light source was not commercially available, and will require a research and development effort to produce. Three vendors have responded positively with proposed design solutions. Ophir has decided to conduct short path optical laboratory experiments to verify the existence of methane and absorption at the specified wavelength, prior to proceeding with the light source selection. Techniques to eliminate common mode noise were also evaluated during the laboratory tests. Finally, Ophir has included a summary of the potential concerns for project success and has established future goals.

  10. Development of a fiber-optic sensor for hydrogen leak detection

    Energy Technology Data Exchange (ETDEWEB)

    Benson, D.K.; Tracy, C.E. [National Renewable Energy Lab., Golden, CO (United States)

    1995-09-01

    The real and perceived risks of hydrogen fuel use, particularly in passenger vehicles, will require extensive safety precautions including hydrogen leak detection. Conventional hydrogen gas sensors require electrical wiring and may be too expensive for deployment in multiple locations within a vehicle. In this recently initiated project, we are attempting to develop a reversible, thin-film, chemochromic sensor that can be applied to the end of a polymer optical fiber. The presence of hydrogen gas causes the film to become darker. A light beam transmitted from a central instrument in the vehicle along the sensor fibers will be reflected from the ends of the fiber back to individual light detectors. A decrease in the reflected light signal will indicate the presence and concentration of hydrogen in the vicinity of the fiber sensor. The typical thin film sensor consists of a layer of transparent, amorphous tungsten oxide covered by a very thin reflective layer of palladium. When the sensor is exposed to hydrogen, a portion of the hydrogen is dissociated, diffuses through the palladium and reacts with the tungsten oxide to form a blue insertion compound, H{sub X}WO{sub 3}- When the hydrogen gas is no longer present, the hydrogen will diffuse out of the H{sub X}WO{sub 3} and oxidize at the palladium/air interface, restoring the tungsten oxide film and the light signal to normal. The principle of this detection scheme has already been demonstrated by scientists in Japan. However, the design of the sensor has not been optimized for speed of response nor tested for its hydrogen selectivity in the presence of hydrocarbon gases. The challenge of this project is to modify the basic sensor design to achieve the required rapid response and assure sufficient selectivity to avoid false readings.

  11. Semi-empirical AGN detection threshold in spectral synthesis studies of Lyman-continuum-leaking early-type galaxies

    Science.gov (United States)

    Cardoso, Leandro S. M.; Gomes, Jean-Michel; Papaderos, Polychronis

    2016-10-01

    Various lines of evidence suggest that the cores of a large portion of early-type galaxies (ETGs) are virtually evacuated of warm ionised gas. This implies that the Lyman-continuum (LyC) radiation produced by an assumed active galactic nucleus (AGN) can escape from the nuclei of these systems without being locally reprocessed into nebular emission, which would prevent their reliable spectroscopic classification as Seyfert galaxies with standard diagnostic emission-line ratios. The spectral energy distribution (SED) of these ETGs would then lack nebular emission and be essentially composed of an old stellar component and the featureless power-law (PL) continuum from the AGN. A question that arises in this context is whether the AGN component can be detected with current spectral population synthesis in the optical, specifically, whether these techniques effectively place an AGN detection threshold in LyC-leaking galaxies. To quantitatively address this question, we took a combined approach that involves spectral fitting with Starlight of synthetic SEDs composed of stellar emission that characterises a 10 Gyr old ETG and an AGN power-law component that contributes a fraction 0 ≤ xAGN nuclear activity may be missing in the AGN demographics.

  12. Infrared hyperspectral tunable filter imaging spectrometer for remote leak detection, chemical speciation, and stack/vent analysis applications

    Science.gov (United States)

    Hinnrichs, Michele

    2002-02-01

    With support from the Department of Energy, the State of California and the Gas Technology Institute, Pacific Advanced Technology is developing a small field portable infrared imaging spectrometer (Sherlock) based on the advances in hyperspectral tunable filter technology, that will be applied to the detection of fugitive gas leaks. This imaging spectrometer uses the Image Multi-spectral Sensing (IMSS) diffractive optic tunable filter invented by Pacific Advanced Technology . The Sherlock has an embedded digital signal processor for real time detection of the gas leak while surrounded by severe background noise. The infrared sensor engine is a 256 x 320 midwave cooled focal plane array which spans the spectral range from 3 to 5 microns, ideal for most hydrocarbon leaks. The technology is by no means limited to this spectral region, and can just as easily work in the longwave infrared from 8 to 12 microns for chemical detection applications. This paper will present the design of the Sherlock camera as well as processed data collected at a gas processing plant and an instrumented kiln at LSU using the prototype camera. The processed data shows that the IMSS imaging spectrometer, using an all passive approach, has the sensitivity to detect methane gas leaks at short range with a flow rate as low as 0.01 scfm2. In addition, the IMSS imaging spectrometer can measure hot gas plumes at longer ranges. As will be shown in this paper the IMSS can detect and image warm species gas additives of methane and propane in the Kiln exhaust stack. The methane injected gas with a concentration of 72 ppm and the propane with a concentration of 49 ppm (as seen by the IMSS sensor) at a range of 60 meters. The atmospheric path was a stressing environment, being hot and humid, for any imaging infrared spectrometer.

  13. Detection of UCP1 protein and measurements of dependent GDP-sensitive proton leak in non-phosphorylating thymus mitochondria.

    Science.gov (United States)

    Clarke, Kieran J; Carroll, Audrey M; O'Brien, Gemma; Porter, Richard K

    2015-01-01

    Over several years we have provided evidence that uncoupling protein 1 (UCP1) is present in thymus mitochondria. We have demonstrated the conclusive evidence for the presence of UCP1 in thymus mitochondria and we have been able to demonstrate a GDP-sensitive UCP1-dependent proton leak in non-phosphorylating thymus mitochondria. In this chapter, we show how to detect UCP1 in mitochondria isolated from whole thymus using immunoblotting. We show how to measure GDP-sensitive UCP1-dependent oxygen consumption in non-phosphorylating thymus mitochondria and we show that increased reactive oxygen species production occurs on addition of GDP to non-phosphorylating thymus mitochondria. We conclude that reactive oxygen species production rate can be used as a surrogate for detecting UCP1 catalyzed proton leak activity in thymus mitochondria.

  14. Proposed strategy for leak detection, monitoring, and mitigation (LDMM) during Hanford single-shell tank waste retrieval

    Energy Technology Data Exchange (ETDEWEB)

    Iwatate, D.F., Westinghouse Hanford

    1996-07-08

    This document proposes a strategy to address issues related to leakage from single-shell tanks (SSTs) during sluicing. A set of criteria are proposed to capture the relevant issues pertaining to leak detection, monitoring, and mitigation (LDMM), and allow DOE-RL, the Contractor, Ecology, and Hanford Stakeholders to reach consensus on allowable leakage volumes (ALVs). Technical studies and findings that support the proposed strategy, and ALV criteria, are summarized and referenced. This document specifically addresses LDMM for SSTs at Hanford, Washington.

  15. Malignant Hemispheric Cerebral Infarction Associated with Idiopathic Systemic Capillary Leak Syndrome

    Directory of Open Access Journals (Sweden)

    Kei Miyata

    2013-10-01

    Full Text Available Idiopathic systemic capillary leak syndrome (ISCLS is a rare condition that is characterized by unexplained episodic capillary hyperpermeability due to a shift of fluid and protein from the intravascular to the interstitial space. This results in diffuse general swelling, fetal hypovolemic shock, hypoalbuminemia, and hemoconcentration. Although ISCLS rarely induces cerebral infarction, we experienced a patient who deteriorated and was comatose as a result of massive cerebral infarction associated with ISCLS. In this case, severe hypotensive shock, general edema, hemiparesis, and aphasia appeared after serious antecedent gastrointestinal symptoms. Progressive life-threatening ischemic cerebral edema required decompressive hemicraniectomy. The patient experienced another episode of severe hypotension and limb edema that resulted in multiple extremity compartment syndrome. Treatment entailed forearm and calf fasciotomies. Cerebral edema in the ischemic brain progresses rapidly in patients suffering from ISCLS. Strict control of fluid volume resuscitation and aggressive diuretic therapy may be needed during the post-leak phase of fluid remobilization.

  16. Active standoff detection of CH4 and N2O leaks using hard-target backscattered light using an open-path quantum cascade laser sensor

    Science.gov (United States)

    Diaz, Adrian; Thomas, Benjamin; Castillo, Paulo; Gross, Barry; Moshary, Fred

    2016-05-01

    Fugitive gas emissions from agricultural or industrial plants and gas pipelines are an important environmental concern as they contribute to the global increase of greenhouse gas concentrations. Moreover, they are also a security and safety concern because of possible risk of fire/explosion or toxicity. This study presents standoff detection of CH4 and N2O leaks using a quantum cascade laser open-path system that retrieves path-averaged concentrations by collecting the backscattered light from a remote hard target. It is a true standoff system and differs from other open-path systems that are deployed as point samplers or long-path transmission systems that use retroreflectors. The measured absorption spectra are obtained using a thermal intra-pulse frequency chirped DFB quantum cascade laser at ~7.7 µm wavelength range with ~200 ns pulse width. Making fast time resolved observations, the system simultaneously realizes high spectral resolution and range to the target, resulting in path-averaged concentration retrieval. The system performs measurements at high speed ~15 Hz and sufficient range (up to 45 m, ~148 feet) achieving an uncertainty of 3.1 % and normalized sensitivity of 3.3 ppm m Hz-1/2 for N2O and 9.3 % and normalized sensitivity of 30 ppm m Hz-1/2 for CH4 with a 0.31 mW average power QCL. Given these characteristics, this system is promising for mobile or multidirectional search and remote detection of gas leaks.

  17. Implementation of leak detection techniques in ducts with critical regimen multiphase flow; Implementacao de tecnicas de deteccao de vazamentos em dutos em regime de escoamento multifasico critico

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Rodrigo S.; Maitelli, Andr L.; Doria Neto, Adriao D.; Salazar, Andres O. [Rio Grande do Norte Univ., Natal, RN (Brazil)

    2005-07-01

    This paper presents signals processing techniques and artificial neural networks to identify leaks in multiphase flow pipeline. The greatest difficulty on traditional methods of leak detection (volume balance, pressure point analysis, etc) is that they are insufficient to design an adequate profile for the real conditions of oil pipeline transport. These difficult conditions goes since unevenly soil, that cause columns or vacuum throughout pipelines, until the presence of multi phases like water, gas and oil; plus other components as sand, which use to produce discontinuous flow off and diverse variations. To attenuate these difficulties, the transform wavelet was used to map the signal pressure in different resolution plan allowing the extraction of descriptors that identify leaks patterns and with then to provide training for the neural network multilayer perceptron (MLP) to learning of how to classify this pattern and report whenever this characterize leaks. During the tests were used transient and regime signals and pipelines with punctures with size variations from 1/2'' to 1'' of diameter to simulate leaks and, this way, it was possible to detect leaks with a time window of two minutes. The result show that the proposed descriptors considered, based in statistical methods applied in domain transform, are sufficient to identify leaks patterns and make it possible to train the neural classifier to indicate the occurrence of pipeline leaks. (author)

  18. Implementing a Compressed Air System Leak Management Program at an Automotive Plant (Visteon's Monroe Plant)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2001-01-01

    The energy team at Visteon’s Monroe plant, formerly owned by Ford Motor Company, implemented an ongoing compressed air system leak management program. The team developed an approach that combined a traditional “find and fix” effort with an innovative implementation and marketing program. As a result of the leak management program, compressed air system consumption was reduced by more than 50% on a per production unit basis.

  19. DETECTION OF HISTORICAL PIPELINE LEAK PLUMES USING NON-INTRUSIVE SURFACE-BASED GEOPHYSICAL TECHNIQUES AT THE HANFORD NUCLEAR SITE WASHINGTON USA

    Energy Technology Data Exchange (ETDEWEB)

    SKORSKA MB; FINK JB; RUCKER DF; LEVITT MT

    2010-12-02

    Historical records from the Department of Energy Hanford Nuclear Reservation (in eastern WA) indicate that ruptures in buried waste transfer pipelines were common between the 1940s and 1980s, which resulted in unplanned releases (UPRs) of tank: waste at numerous locations. A number of methods are commercially available for the detection of active or recent leaks, however, there are no methods available for the detection of leaks that occurred many years ago. Over the decades, leaks from the Hanford pipelines were detected by visual observation of fluid on the surface, mass balance calculations (where flow volumes were monitored), and incidental encounters with waste during excavation or drilling. Since these detection methods for historic leaks are so limited in resolution and effectiveness, it is likely that a significant number of pipeline leaks have not been detected. Therefore, a technology was needed to detect the specific location of unknown pipeline leaks so that characterization technologies can be used to identify any risks to groundwater caused by waste released into the vadose zone. A proof-of-concept electromagnetic geophysical survey was conducted at an UPR in order to image a historical leak from a waste transfer pipeline. The survey was designed to test an innovative electromagnetic geophysical technique that could be used to rapidly map the extent of historical leaks from pipelines within the Hanford Site complex. This proof-of-concept test included comprehensive testing and analysis of the transient electromagnetic method (TEM) and made use of supporting and confirmatory geophysical methods including ground penetrating radar, magnetics, and electrical resistivity characterization (ERC). The results for this initial proof-of-concept test were successful and greatly exceeded the expectations of the project team by providing excellent discrimination of soils contaminated with leaked waste despite the interference from an electrically conductive pipe.

  20. A survey and description of candidate technologies to support single shell tank waste retrieval, leak detection, monitoring, and mitigation

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, R.E.; Teel, S.S.; Wegener, W.H.; Iwatate, D.F.

    1995-09-01

    This report was initially designed to provide a comprehensive review of potential leak detection technologies (LDTs). To this end, the report would contain several sections outlining the selection process. The purpose was twofold:(l) the reader would have a clear understanding of why specific technologies were recommended or not recommended, and (2) the reader could apply the same process in the future as new LDTs become available. Curtailment of project scope has prevented the development of the requisite judging criteria. The report has been modified accordingly. Section 2 of this report presents the baseline and guiding assumptions that were used to judge the LDTs. These assumptions include the environment where the technologies would be employed, the potential leak detection targets, and anticipated leak mechanisms. Section 3 presents a brief review of the methods used to arrive at the recommended LDTs. It also includes a description of the different technology families considered. Section 4 presents the recommended LDTs along with detailed descriptions of each that include sensitivities, operating parameters, and costs.

  1. A Small Leak Detection Method Based on VMD Adaptive De-Noising and Ambiguity Correlation Classification Intended for Natural Gas Pipelines

    Directory of Open Access Journals (Sweden)

    Qiyang Xiao

    2016-12-01

    Full Text Available In this study, a small leak detection method based on variational mode decomposition (VMD and ambiguity correlation classification (ACC is proposed. The signals acquired from sensors were decomposed using the VMD, and numerous components were obtained. According to the probability density function (PDF, an adaptive de-noising algorithm based on VMD is proposed for noise component processing and de-noised components reconstruction. Furthermore, the ambiguity function image was employed for analysis of the reconstructed signals. Based on the correlation coefficient, ACC is proposed to detect the small leak of pipeline. The analysis of pipeline leakage signals, using 1 mm and 2 mm leaks, has shown that proposed detection method can detect a small leak accurately and effectively. Moreover, the experimental results have shown that the proposed method achieved better performances than support vector machine (SVM and back propagation neural network (BP methods.

  2. A Small Leak Detection Method Based on VMD Adaptive De-Noising and Ambiguity Correlation Classification Intended for Natural Gas Pipelines.

    Science.gov (United States)

    Xiao, Qiyang; Li, Jian; Bai, Zhiliang; Sun, Jiedi; Zhou, Nan; Zeng, Zhoumo

    2016-12-13

    In this study, a small leak detection method based on variational mode decomposition (VMD) and ambiguity correlation classification (ACC) is proposed. The signals acquired from sensors were decomposed using the VMD, and numerous components were obtained. According to the probability density function (PDF), an adaptive de-noising algorithm based on VMD is proposed for noise component processing and de-noised components reconstruction. Furthermore, the ambiguity function image was employed for analysis of the reconstructed signals. Based on the correlation coefficient, ACC is proposed to detect the small leak of pipeline. The analysis of pipeline leakage signals, using 1 mm and 2 mm leaks, has shown that proposed detection method can detect a small leak accurately and effectively. Moreover, the experimental results have shown that the proposed method achieved better performances than support vector machine (SVM) and back propagation neural network (BP) methods.

  3. Clinical and Pathological Findings of a Fatal Systemic Capillary Leak Syndrome (Clarkson Disease)

    Science.gov (United States)

    Zancanaro, Andrea; Serafini, Francesco; Fantin, Giuseppe; Murer, Bruno; Cicardi, Marco; Bonanni, Luca; Dalla Vestra, Michele; Scanferlato, Mauro; Mazzanti, Giovanni; Presotto, Fabio

    2015-01-01

    Abstract Systemic capillary leak syndrome (SCLS) is a rare disorder with episodes of hypotension, hypoalbuminemia, and hemoconcentration. During attacks endothelial hyperpermeability results in leakage of plasma proteins into the interstitial space. Attacks vary in severity and may be lethal. A 49-year-old previously healthy man was admitted to hospital for hypovolemic shock, anasarca with pleuropericardial effusion, muscle fatigue, and oliguria occurring after a flu-like syndrome. Laboratory data showed an increase in hematocrit (65%), leucocytes (24.590 μ/L), creatinine (2.5 mg/dL), creatine phosphokinase (10.000 U/L), and a decrease in serum albumin (17 g/L) without proteinuria. Immunoglobulins of class G/λ monoclonal gammopathy were detected (1.3 g/L). The initial suspicions addressed to a protein-loosing syndrome or to an effort-related rhabdomyolysis. Initial therapy was based on steroids, albumin, and high molecular weight plasma expanders (hydroxyethyl starch). Because of high hematocrit, phlebotomy was also performed. The patient had complete clinical remission and a diagnosis of SCLS was finally made. He received prophylactic therapy with verapamil and theophylline that was self-stopped for intolerance (hypotension and tachycardia). He had a new crisis 2 days after a physical effort, and was admitted in intensive care unit. The patient died for severe hypovolemic shock with multiorgan failure and sudden cardiac arrest 15 hours after hospital admission. Postmortem investigation revealed massive interstitial edema of main organs with myocardial hyperacute ischemia. Studies on SCLS are limited for the rarity of the disease and its unpredictable course. Both prophylactic and acute crisis treatments are empirical and optimal management of severe attacks is still lacking. PMID:25738482

  4. Doppler method leak detection for LMFBR steam generators. Pt. 2. Detection characteristics of bubble in-water using large scale SG model

    Energy Technology Data Exchange (ETDEWEB)

    Kumagai, Hiromichi [Central Research Inst. of Electric Power Industry, Komae, Tokyo (Japan). Komae Research Lab

    2000-06-01

    To prevent the expansion of tube damage and to maintain structural integrity in the steam generators (SGs) of a fast breeder reactor (FBR), it is necessary to detect precisely and immediately the leakage of water from heat transfer tubes. Therefore, an active acoustic method was developed. Previous studies have revealed that, in practical steam generators, the active acoustic method can detect bubbles of 10 l/s within 10 seconds. However to prevent the expansion of damage to neighboring tubes, it is necessary to detect smaller leakages of water from the heat transfer tubes. The Doppler method is designed to detect small leakages and to find the source of a leak before damage spreads to neighboring tubes. The detection sensitivity of the Doppler method and the influence of background noise were investigated experimentally. In-water experiments were performed using an SG full-sector model that simulates actual SGs. The results show that the Doppler method can detect bubbles of 0.1 l/s (equivalent to a water leak rate of about 0.1 g/s) within a few seconds and that the background noise has little effect on water leak detection performance. The Doppler method thus has great potential for the detection of water leakage in SGs. (author)

  5. High Temperature Humidity Sensor for Detection of Leak Through Slits and Cracks in Pressurized Nuclear Power Reactor Pipes

    Directory of Open Access Journals (Sweden)

    Debdulal Saha

    2007-03-01

    Full Text Available The leak before break (LBB concept is well known to nuclear power reactor. The problem is common to water power reactor. This is based on the premise that a detectable leak will develop before catastrophic break occurs. The main purpose of the present study is to develop tape cast MgCr2O4+35mole% TiO2 and gel cast g-Al2O3 humidity sensor for use in LBB applications at 3000C. The material capacitance varies with transient injection of water vapour adsorption. In actual plant, the sensors are placed on a steam pipe surrounded by heat insulation. The pipe unites the nuclear reactor and power generator. The analysis of humidity distribution in the annulus is calculated assuring leak rate 0.1gpm in a 30 m long tube. In this paper, analysis is done on the basis of the two types of sensor using AC frequency. Performance characteristics are observed for the LLB application.

  6. Systemic Capillary Leak Syndrome as an Initial Presentation of ALK-Negative Anaplastic Large Cell Lymphoma

    Directory of Open Access Journals (Sweden)

    Laura S. Lourdes

    2012-01-01

    Full Text Available Systemic capillary leak syndrome (SCLS is a rare disease characterized by third spacing of plasma into the extravascular compartment, leading to anasarca, hemoconcentration, and hypovolemic shock. It has been rarely associated with lymphomas, and reports usually indicate that it occurs after antineoplastic treatment. We present the case of a patient with ALK-negative anaplastic large cell lymphoma who presented with SCLS as the initial manifestation of her lymphoma. The SCLS resolved with treatment of the malignancy with steroids and chemotherapy.

  7. Active stand-off detection of gas leaks using an open-path quantum cascade laser sensor in a backscatter configuration

    Science.gov (United States)

    Diaz, Adrian; Thomas, Benjamin; Castillo, Paulo; Gross, Barry; Moshary, Fred

    2005-05-01

    Fugitive gas emissions from agricultural or industrial plants and gas pipelines are an important environmental concern as they can contribute to the global increase of greenhouse gas concentration. Moreover, they are also a security and safety concern because of possible risk of fire/explosion or toxicity. This study presents gas concentration measurements using a quantum cascade laser open path system (QCLOPS). The system retrieves the path-averaged concentration of N2O by collecting the backscattered light from a scattering target. The gas concentration measurements have a high temporal resolution (68 ms) and are achieved at sufficient range (up to 40 m, ~ 130 feet) with a detection limit of 0.4 ppm for N2O. Given these characteristics, this system is promising for mobile/multidirectional remote detection and evaluation of gas leaks.

  8. On the Acoustic Filtering of the Pipe and Sensor in a Buried Plastic Water Pipe and its Effect on Leak Detection: An Experimental Investigation

    Science.gov (United States)

    Almeida, Fabrício; Brennan, Michael; Joseph, Phillip; Whitfield, Stuart; Dray, Simon; Paschoalini, Amarildo

    2014-01-01

    Acoustic techniques have been used for many years to find and locate leaks in buried water distribution systems. Hydrophones and accelerometers are typically used as sensors. Although geophones could be used as well, they are not generally used for leak detection. A simple acoustic model of the pipe and the sensors has been proposed previously by some of the authors of this paper, and their model was used to explain some of the features observed in measurements. However, simultaneous measurements of a leak using all three sensor-types in controlled conditions for plastic pipes has not been reported to-date and hence they have not yet been compared directly. This paper fills that gap in knowledge. A set of measurements was made on a bespoke buried plastic water distribution pipe test rig to validate the previously reported analytical model. There is qualitative agreement between the experimental results and the model predictions in terms of the differing filtering properties of the pipe-sensor systems. A quality measure for the data is also presented, which is the ratio of the bandwidth over which the analysis is carried out divided by the centre frequency of this bandwidth. Based on this metric, the accelerometer was found to be the best sensor to use for the test rig described in this paper. However, for a system in which the distance between the sensors is large or the attenuation factor of the system is high, then it would be advantageous to use hydrophones, even though they are invasive sensors. PMID:24658622

  9. On the Acoustic Filtering of the Pipe and Sensor in a Buried Plastic Water Pipe and its Effect on Leak Detection: An Experimental Investigation

    Directory of Open Access Journals (Sweden)

    Fabrício Almeida

    2014-03-01

    Full Text Available Acoustic techniques have been used for many years to find and locate leaks in buried water distribution systems. Hydrophones and accelerometers are typically used as sensors. Although geophones could be used as well, they are not generally used for leak detection. A simple acoustic model of the pipe and the sensors has been proposed previously by some of the authors of this paper, and their model was used to explain some of the features observed in measurements. However, simultaneous measurements of a leak using all three sensor-types in controlled conditions for plastic pipes has not been reported to-date and hence they have not yet been compared directly. This paper fills that gap in knowledge. A set of measurements was made on a bespoke buried plastic water distribution pipe test rig to validate the previously reported analytical model. There is qualitative agreement between the experimental results and the model predictions in terms of the differing filtering properties of the pipe-sensor systems. A quality measure for the data is also presented, which is the ratio of the bandwidth over which the analysis is carried out divided by the centre frequency of this bandwidth. Based on this metric, the accelerometer was found to be the best sensor to use for the test rig described in this paper. However, for a system in which the distance between the sensors is large or the attenuation factor of the system is high, then it would be advantageous to use hydrophones, even though they are invasive sensors.

  10. The Application of Data Acquisition Control Technology in Flammable Refrigerant Leak Detection Alarm System Based on RS-485 Bus%基于RS-485总线的数据采集控制技术在可燃性制冷剂泄露检测警报系统中的应用

    Institute of Scientific and Technical Information of China (English)

    郭军

    2014-01-01

    本文主要介绍泓格RS-485网络在工业控制中的优势以及基于RS-485总线的数据采集系统的特点及应用案例分析。泓格基于RS-485总线的远程数据采集控制系统方案丰富多彩,提供用户以广泛的选择。新型环保制冷剂多是可燃性天然物质,在期产业化应用中存在易燃易爆的危险性,本文以案例形式介绍了使用RS-485总线的数据采集控制技术在可燃性制冷剂泄露检测警报系统中的技术应用。%This paper mainly introduces the advantage of case RS-485 network of ICP DAS in industrial control, and the characteristics of data acquisition system and application case analysis based on RS-485 bus. Based on RS-485 bus, ICP DAS’s remote data acquisition control system schemes is plentiful. It provides the users with wide selection. Most of the new environment-friendly refrigerants are flammability natural-occurring substance. Thus, it has the dangerousness of flammable and combustible in the period of industrialization application. Combined with the cases, this paper introduces the application of data acquisition control technology in flammable refrigerant leak detection alarm system based on RS-485 bus.

  11. Application of Leak Detection and Location Technology Based on Ultrasonic for Manned Spacecraft%基于超声的气体泄漏检测与定位技术在载人航天器中的应用

    Institute of Scientific and Technical Information of China (English)

    马永成; 陈青松

    2009-01-01

    The fundamental principle of leak detection and location technology based on ultrasonic is introduced in this paper.Both portable leak detection equipment and autonomous ultrasonic leak detection and location equipment are introduced,including their system composition,principle and working mode.The application of these equipments for the ISS and Shuttle is introduced.A scheme of ultrasonic leak detection and location that can be used for the space station of China is developed.%介绍了基于超声的气体泄漏检测与定位技术的基本原理;介绍了便携式超声检漏、无线超声自动检漏这两类已有设备的组成、工作原理及其在国际空间站、美国航天飞机上的应用情况.以此为参照,初步提出了一种可用于我国未来空间站建设的气体泄漏检测与定位方案.

  12. Bayesian belief network for CO2 leak detection by near-surface flux rates for CO2 and perfluorocarbon (PFC) tracer

    Science.gov (United States)

    Yang, Y.; Small, M. J.; Ogretim, E.; Gray, D. D.; Bromhal, G. S.; Strazisar, B. R.; Wells, A. W.

    2010-12-01

    To incorporate the use of multiple geologic sequestration monitoring techniques, a Bayesian Belief Network (BBN) for leak detection inference is applied to integrate the information provided by different techniques deployed at a site. In this study, two monitoring methods, near-surface soil CO2 flux and perfluorocarbon (PFC) tracer concentration, are included in the BBN. First, possible near-surface flux rates for CO2 and PFC tracer as a function of distance from a leakage point are simulated by TOUGH2, given different leakage rates and permeabilities. Then, the natural near-surface CO2 flux and background PFC tracer concentration measured at the Zero Emission Research and Technology (ZERT) site are used to determine critical values for leak inference and to calculate the probabilities of leak detection given a monitoring network. A BBN of leak detection is established by combing the TOUGH2 simulations and the background characterization of near-surface CO2 flux and PFC tracer at the sequestration site. The results show a positive correlation between the detection abilities of PFC tracer and soil CO2 flux, but the PFC tracer is more sensitive for detecting a leak in most cases. The BBN of leak detection including both soil CO2 flux and PFC tracer concentration gives an integrated probability estimation of leak detection for different permeability and leakage rates for a given monitoring network. A BBN developed using the proposed methodology can be used to help site engineers and decision makers to evaluate leakage signals and the risk of undetected leakage, given a suite of monitoring techniques and site conditions.

  13. 空间站泄漏监测报警方案设想——绝压法%Assumption on Leak Monitoring and Alarming for Space Station --Absolute Pressure Leak Detection

    Institute of Scientific and Technical Information of China (English)

    回天力; 刘刚; 高静; 贾东永; 杨纯; 孙国辉

    2012-01-01

    介绍了各国空间站泄漏监测技术的背景及绝压法泄漏监测的原理,在分析空间站舱体内、外环境的基础上提出了空间站泄漏监测报警模式,及通过测量舱内氮分压进行泄漏监测的技术方案,提出了"反应时间占用率"的概念并以此作为评判监测报警效果的依据,最终对比得出氮分压间接监测法可作为有航天员值守期间空间站的泄漏监测与报警方案。%The background of space station leak monitoring technology and the principle of absolute pressure leak detection are introduced. Based on the analysis of internal and external environment of space station cabin, the monitoring and alarming mode for leak detection is proposed, and the technical scheme of leak monitoring by measuring the partial pressure of nitrogen in the cabin is also introduced. The concept of "Occupation Ratio of Response Time" is put for- ward and taken as a basis for judging the effect of monitoring and alarming. It is concluded that the indirect monitoring method by measuring the partial pressure of nitrogen can be used as a leak monitoring and alarming method when the space station is tended by astronauts.

  14. How Useful is Glucose Detection in Diagnosing Cerebrospinal Fluid Leak? The Rational Use of CT and Beta-2 Transferrin Assay in Detection of Cerebrospinal Fluid Fistula

    Directory of Open Access Journals (Sweden)

    Danny T.M. Chan

    2004-01-01

    Conclusions: Glucose detection using Glucostix test strips is not recommended as a confirmatory test due to its lack of specificity and sensitivity. In the presence of a skull base fracture on CT and a clinical CSF leak, there is no need for a further confirmatory test. In cases where a confirmatory test is needed, the beta-2 transferrin assay is the test of choice because of its high sensitivity and specificity.

  15. 油箱泄漏的超声检测方法%Ultrasonic Leak Detection Methods of Fuel Tank

    Institute of Scientific and Technical Information of China (English)

    薛花; 吴迪; 王亚平; 赵振宁; 陈天夫; 滕永平

    2016-01-01

    The paper analyzed the factors influencing the bubble detection rate in ultrasonic leak detection for fuel tank,studied the characteristics of ultrasonic reflection field of transducer,and proposed a new 8-channel parallel cyclic scanning detection mode, maximizing the repetition frequency of each transducer.Then comparative experiment tests were conducted between our 8-channel parallel ultrasonic leak detector and the traditional one.The results showed that,compared to single-channel scanning mode,the multi-channel parallel testing method had much higher detection rates when the single air bubble or long time interval bubbles needed to be detected.So this method was more effective to detect smaller tank leakage (μm diameter).%分析了影响油箱泄漏超声检测中气泡检出率的相关因素,研究了超声检测探头声场特点,提出了8路并行循环检测的工作模式,最大限度地提高了每个探头的重复工作频率.将自行搭建的8路并行超声波检测装置和传统超声测漏仪器进行了对比试验.结果表明,相对于单路扫描工作方式,多路并行检测对产生时间间隔较大气泡和单个气泡具有较高的检出率,可以检出更微小的缺陷(微米量级).

  16. CSF leak

    Science.gov (United States)

    ... rarely). Drainage of CSF from the nose (rarely). Exams and Tests The health care provider will perform ... usually recommended. Drinking more fluids, especially drinks with caffeine, can help slow or stop the leak and ...

  17. Active acoustic leak detection for LMFBR steam generator. Pt. 5. Experiment for detection of bubbles using the SG full sector model

    Energy Technology Data Exchange (ETDEWEB)

    Kumagai, Hiromichi [Central Research Inst. of Electric Power Industry, Komae, Tokyo (Japan). Komae Research Lab.

    1997-05-01

    In order to prevent the expansion of tube damages and to maintain structural safety in steam generators (SG) of fast breeder reactors (FBR), it is necessary to detect precisely and immediately the leakage of water from tubes of heat exchangers. Therefore, an active acoustic method, which detects the sound attenuation due to bubbles generated in the sodium-water reactions, it being developed. In this paper, the attenuation characteristics of sound attenuated by bubbles and influence of background noise are investigated experimentally by using an SG full sector model (diameter ratio about 1/1, height ratio about 1/7) simulating the actual SG. As an experimental result, the received sound attenuation for ten seconds was more than 10 dB from air bubble injection when injected bubble of 10 l/s (equivalence water leak rate about 10 g/s). The attenuation of sound are least affected by bubble injection position of heat exchanger tube bunch department. And the time was about 25 seconds till the sound attenuation became 10 dB in case of quantity of air bubble 1 l/s (equivalent water leak rate about 1 g/s). It is clarified that the background noise hardly influenced water leak detection performance as a result of having examined influence of background noise. (author)

  18. The Demonstration of a Robotic External Leak Locator on the International Space Station

    Science.gov (United States)

    Naids, Adam; Rossetti, Dino; Bond, Tim; Johnson, Brien; Huang, Alvin; Deal, Alexandra; Fox, Katie; Heiser, Michael; Hartman, William; Mikatarian, Ronald

    2017-01-01

    The International Space Station (ISS) and all currently conceivable future manned spacecraft are susceptible to mission impacts due to fluid/gas leaks to the exterior environment. For example, there is a well-known risk of ammonia leaks from the ISS External Thermal Control System loops and currently no method to locate them. It was, therefore, critical to develop a method for detecting and locating leaks to preserve vehicle health. The Robotic External Leak Locator (RELL) was developed and deployed to the ISS to provide this capability. An on-orbit validation and demonstration was successfully completed in December 2016 and leak locating operations occurred in February 2017. This paper discusses the results of those exercises including measurements of the environment around ISS, detection of the small ammonia leak and implementation of leak locating methodologies.

  19. Assessment of Current Inservice Inspection and Leak Monitoring Practices for Detecting Materials Degradation in Light Water Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Michael T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Simonen, Fredric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Muscara, Joseph [US Nuclear Regulatory Commission (NRC), Rockville, MD (United States); Doctor, Steven R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kupperman, David S. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-09-01

    An assessment was performed to determine the effectiveness of existing inservice inspection (ISI) and leak monitoring techniques, and recommend improvements, as necessary, to the programs as currently performed for light water reactor (LWR) components. Information from nuclear power plant (NPP) aging studies and from the U. S. Nuclear Regulatory Commission’s Generic Aging Lessons Learned (GALL) report (NUREG-1801) was used to identify components that have already experienced, or are expected to experience, degradation. This report provides a discussion of the key aspects and parameters that constitute an effective ISI program and a discussion of the basis and background against which the effectiveness of the ISI and leak monitoring programs for timely detection of degradation was evaluated. Tables based on the GALL components were used to systematically guide the process, and table columns were included that contained the ISI requirements and effectiveness assessment. The information in the tables was analyzed using histograms to reduce the data and help identify any trends. The analysis shows that the overall effectiveness of the ISI programs is very similar for both boiling water reactors (BWRs) and pressurized water reactors (PWRs). The evaluations conducted as part of this research showed that many ISI programs are not effective at detecting degradation before its extent reached 75% of the component wall thickness. This work should be considered as an assessment of NDE practices at this time; however, industry and regulatory activities are currently underway that will impact future effectiveness assessments. A number of actions have been identified to improve the current ISI programs so that degradation can be more reliably detected.

  20. Multi-Spectral imaging of vegetation for detecting CO2 leaking from underground

    Energy Technology Data Exchange (ETDEWEB)

    Rouse, J.H.; Shaw, J.A.; Lawrence, R.L.; Lewicki, J.L.; Dobeck, L.M.; Repasky, K.S.; Spangler, L.H.

    2010-06-01

    Practical geologic CO{sub 2} sequestration will require long-term monitoring for detection of possible leakage back into the atmosphere. One potential monitoring method is multi-spectral imaging of vegetation reflectance to detect leakage through CO{sub 2}-induced plant stress. A multi-spectral imaging system was used to simultaneously record green, red, and near-infrared (NIR) images with a real-time reflectance calibration from a 3-m tall platform, viewing vegetation near shallow subsurface CO{sub 2} releases during summers 2007 and 2008 at the Zero Emissions Research and Technology field site in Bozeman, Montana. Regression analysis of the band reflectances and the Normalized Difference Vegetation Index with time shows significant correlation with distance from the CO{sub 2} well, indicating the viability of this method to monitor for CO{sub 2} leakage. The 2007 data show rapid plant vigor degradation at high CO{sub 2} levels next to the well and slight nourishment at lower, but above-background CO{sub 2} concentrations. Results from the second year also show that the stress response of vegetation is strongly linked to the CO{sub 2} sink-source relationship and vegetation density. The data also show short-term effects of rain and hail. The real-time calibrated imaging system successfully obtained data in an autonomous mode during all sky and daytime illumination conditions.

  1. Methane, Ethane, and Propane Sensor for Real-time Leak Detection and Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Roscioli, Joseph R. [Aerodyne Research, Inc., Billerica, MA (United States); Herndon, Scott [Aerodyne Research, Inc., Billerica, MA (United States); Nelson, David D. [Aerodyne Research, Inc., Billerica, MA (United States); Yacovitch, Tara [Aerodyne Research, Inc., Billerica, MA (United States)

    2017-03-24

    The Phase I effort demonstrated the technical viability of a fast, sensitive, mobile hydrocarbon monitor. The instrument will enable the oil and gas industry, researchers, and regulators to rapidly identify and chemically profile leaks from facilities. This capability will allow operators to quickly narrow down and mitigate probable leaking equipment, minimizing product loss and penalties due to regulatory non-compliance. During the initial development phase, we demonstrated operation of a prototype monitor that is capable of measuring methane, ethane, and propane at sub-part-per-billion sensitivities in 1 second, using direct absorption infrared spectroscopy. To our knowledge, this is the first instrument capable of fast propane measurements at atmospheric concentrations. In addition, the electrical requirements of the monitor have been reduced from the 1,200 W typical of a spectrometer, to <500 W, making it capable of being powered by a passenger vehicle, and easily deployed by the industry. The prototype monitor leverages recent advances in laser technology, using high-efficiency interband cascade lasers to access the 3 μm region of the mid-infrared, where the methane, ethane, and propane absorptions are strongest. Combined with established spectrometer technology, we have achieved precisions below 200 ppt for each compound. This allows the monitor to measure fast plumes from oil and gas facilities, as well as ambient background concentrations (typical ambient levels are 2 ppm, 1.5 ppb, and 0.7 ppb for methane, ethane and propane, respectively). Increases in instrument operating pressure were studied in order to allow for a smaller 125 W pump to be used, and passive cooling was explored to reduce the cooling load by almost 90% relative to active (refrigerated) cooling. In addition, the simulated infrared absorption profiles of ethane and propane were modified to minimize crosstalk between species, achieving <1% crosstalk between ethane and propane. Finally, a

  2. Accuracy improvement in leak detection of charcoal adsorbers by halide pulse integration method

    Energy Technology Data Exchange (ETDEWEB)

    Kovach, B.J.; Banks, E.M. [NUCON International, Inc., Columbus, OH (United States)

    1997-08-01

    Due to the phaseout of the supply of R-11, which is used as a charcoal adsorber leak-testing agent, several new substitutes have been suggested and tested. Pulse testing using agents with higher boiling points produced longer response times (due to prolonged evaporation and dispersion times). This longer evaporation time alters the pulse shape and lowers the peak concentration. Since the dispersion and evaporation time under different ambient condition are unpredictable, the peak concentration becomes unpredictable as well. One way to eliminate this unpredictability is to determine the area under the curve (of concentration versus time) after test-agent injection rather than the peak concentration (height). This value should be independent of the injection time and evaporation rate as long as the volume of the test agent injected remains constant. Thus, tests were performed with a constant volume injection of test agent but with different injection times and evaporation rates. The area under the curve of concentration versus time was then compared with the peak concentration for each injection. 4 refs., 1 fig.

  3. Localization of a continuous CO2 leak from an isotropic flat-surface structure using acoustic emission detection and near-field beamforming techniques

    Science.gov (United States)

    Yan, Yong; Cui, Xiwang; Guo, Miao; Han, Xiaojuan

    2016-11-01

    Seal capacity is of great importance for the safety operation of pressurized vessels. It is crucial to locate the leak hole timely and accurately for reasons of safety and maintenance. This paper presents the principle and application of a linear acoustic emission sensor array and a near-field beamforming technique to identify the location of a continuous CO2 leak from an isotropic flat-surface structure on a pressurized vessel in the carbon capture and storage system. Acoustic signals generated by the leak hole are collected using a linear high-frequency sensor array. Time-frequency analysis and a narrow-band filtering technique are deployed to extract effective information about the leak. The impacts of various factors on the performance of the localization technique are simulated, compared and discussed, including the number of sensors, distance between the leak hole and sensor array and spacing between adjacent sensors. Experiments were carried out on a laboratory-scale test rig to assess the effectiveness and operability of the proposed method. The results obtained suggest that the proposed method is capable of providing accurate and reliable localization of a continuous CO2 leak.

  4. Leak Detection for Potable Water Lines at Fort Hood: Final Report on Project AR-F-313 for FY05

    Science.gov (United States)

    2007-06-01

    cables, gas lines, etc., sometimes run close to water pipelines , and it is important to be certain that digging will not cause damage to these...sensors to find leaks in the potable water pipelines of West Fort Hood has been demon- strated to be quite good. Two leaks were discovered during the...the Army consider installing PermaLog permanent leak sensors at other installations where potable water pipelines run in sel- dom traveled areas. The

  5. Research on leak fault intelligent detection method for fluid pipeline based on fuzzy classification%基于模糊分类的流体管道泄漏故障智能检测方法研究

    Institute of Scientific and Technical Information of China (English)

    刘金海; 冯健

    2011-01-01

    本文针对基于负压波法管道泄漏实时检测系统误报高和灵敏度低的问题提出一种流体管道泄漏故障智能检测方法,该方法首先给出管道运行参数的确定模型,然后结合模糊算子给出流体管道状态模糊模型,进而利用该模型实现管道故障分类.以这种智能检测方法为核心设计流体管道故泄漏故障智能诊断系统(leak intelligent diagnosis system for fluid pipeline,LIDSFP),通过对某成品油管道实例仿真和在流体管道测试系统上的试验研究,给出了LIDSFP性能指标,进一步分析表明该系统可以有效完成流体管道的泄漏故障诊断.%A leak fault intelligent detection method for fluid pipeline based on fuzzy classifier is proposed, which can decrease false alarms and improve leak detection sensitivity. To complete real-time and exact fault diagnosis of fluid pipeline, a fuzzy classifier for operation states is designed according to the framework of fuzzy expert system. A leak fault intelligent diagnosis system for fluid pipeline ( LIDSFP) was designed with this intelligent method; simulation was carried out to detect faults from the historic operation data of certain petrolatum product fluid pipeline in China.Test study was also carried out on the proposed system and the performance specification of the system is given. Simulation and test results show that the proposed diagnosis system has good performance.

  6. Estimation of leak rate through circumferential cracks in pipes in nuclear power plants

    Directory of Open Access Journals (Sweden)

    Jai Hak Park

    2015-04-01

    Full Text Available The leak before break (LBB concept is widely used in designing pipe lines in nuclear power plants. According to the concept, the amount of leaking liquid from a pipe should be more than the minimum detectable leak rate of a leak detection system before catastrophic failure occurs. Therefore, accurate estimation of the leak rate is important to evaluate the validity of the LBB concept in pipe line design. In this paper, a program was developed to estimate the leak rate through circumferential cracks in pipes in nuclear power plants using the Henry–Fauske flow model and modified Henry–Fauske flow model. By using the developed program, the leak rate was calculated for a circumferential crack in a sample pipe, and the effect of the flow model on the leak rate was examined. Treating the crack morphology parameters as random variables, the statistical behavior of the leak rate was also examined. As a result, it was found that the crack morphology parameters have a strong effect on the leak rate and the statistical behavior of the leak rate can be simulated using normally distributed crack morphology parameters.

  7. Detection of leaks for radioactive tracer in marine duct for transport of liquefied petroleum gas; Deteccion de fugas por radiotrazado en ducto marino para transporte de gas LP

    Energy Technology Data Exchange (ETDEWEB)

    Robles P, E. F.; Benitez S, J. A.; Torre O, J. de la; Cruz S, E. de la; Molina, G.; Hernandez C, J. E.; Flores M, J. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico)]. e mail: efrp@nuclear.inin.mx

    2008-07-01

    In this work the aplication in the oil industry of the technique of radioactive tracer appears for the detection of internal leaks in a submarine duct that gives service as it lines of receipt of liquefied petroleum gas (Gas LP) located in the Mexican coast of the Pacific Ocean. This system of marine pipe is a consistent arrangement of a duct interior of 0.254 m (10 inches) of nominal diameter (N.D.) of steel to the carbon for cryogenic service ASTM A 333, Grade 6, schedule 30, isolated thermally with foam of polyurethane and shielding in a steel tube to the carbon ASTM A 53 Grade A, of 0.508 m (20 inches) N. D., schedule 20, which is recovered by a ballast encircling of concrete of 0.0508 m (2 inches) of thickness, reinforced with mesh metallic, and that 1315 m runs on the marine stratum to a maximum depth of 12.5 m. For the detection of leaks by radiotracer it was used as tracer the radioactive isotope La-140 produced in the TRIGA Mark III Experimental Reactor of the National Institute of Nuclear Research, starting from stable lanthanum nitrate (La(NO{sub 3}){sub 3} 6H{sub 2}O), with an activity of 100 mCi, the one which after having been made logistics tasks, given very particular sea maneuvers and due to the conditions of the work place, in the interior tube was injected in two subsequent stages to cover both duct senses; from earth and from the marine end respectively, there being used fresh water like transport way and submergible sodium iodide detectors (NaI) for the rake of the La-140. At the end of the journeys of pursuit of the radiotracer, it was determine the presence of three leaks points located in the break area of the marine surf to 360 m, 450 m and 495 m of distance of a reference point located in the beach section named Trap of Devils. (Author)

  8. Photoacoustic Detection of Perfluorocarbon Tracers in Air for Application to Leak Detection in Oil-Filled Cables

    Science.gov (United States)

    Zajarevich, N.; Slezak, V.; Peuriot, A.; Villa, G.; Láttero, A.; Crivicich, R.

    2013-09-01

    The underground oil-filled cable consists of a hollow copper conductor surrounded by oiled paper which acts as electrical insulation. The oil flows along the conductor and diffuses through it to the insulating paper. A lead sheath is used as the outer retaining wall. As the deterioration of this cover may cause a loss of insulation fluid, its detection is very important since this high voltage and power cable is used in cities even under sidewalks. The method of perfluorocarbon vapor tracers, based on the injection and subsequent detection of these volatile chemical substances in the vicinity of the cable, is one of the most promising methods, so far used in combination with gas chromatography and mass spectrometry. In this study, the possibility of detecting two different tracers, and , by means of resonant photoacoustic spectroscopy is studied. The beam from a tunable amplitude-modulated laser goes through an aluminum cell with quarter wave filters at both ends of an open resonator and an electret microphone in its center, attached to the walls. The calibration of the system for either substance diluted in chromatographic air showed a higher sensitivity for , so the experiment was completed checking the behavior of this substance in samples prepared with ambient air in order to analyze the application of the system to field studies.

  9. Fundamental study on leak detection of underground gas pipeline using passive acoustic method; Judogata onkyo keisoku ni yoru maisetsu gas dokan hason kasho no kenshutsu ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Jinguji, M.; Imaizumi, H.; Kunimatsu, S.; Isei, T. [National Institute for Resources and Environment, Tsukuba (Japan)

    1997-05-27

    With an objective to detect gas leaking from an underground gas pipeline, discussions have been given on a method which utilizes acoustic characteristics of leakage. On leaking sound generated from damaged portions, the form of damaging was hypothesized as pinholes, and spectra of leaking sounds from holes with different diameters were measured. The dominant frequency decreases as the hole diameter increases, while it is in a region of relatively high frequency of 1 kHz or higher. However, detection from the ground surface was impossible when cover soil has thickness from 0.5 to 1.5 m. In an experiment to measure leaking sound inside the pipe, pressure in the pipe was adjusted to 0.02 atm which is a standard pressure for a low-pressure pipe, and the sound was measured when the hole diameters were varied. In any of the results obtained by varying the hole diameter, spectra having the dominant frequency in the region of 1 kHz or higher were measured. In addition, it was found that sound pressure difference of as much as 50 dB at maximum is generated as compared with a case of no sound leakage. The above results verified that monitoring the high frequency of 1 kHz or higher is effective in detecting leakage from small damages. 2 refs., 4 figs.

  10. Active acoustic leak detection for LMFBR steam generator. Sound attenuation due to bubbles

    Energy Technology Data Exchange (ETDEWEB)

    Kumagai, Hiromichi; Sakuma, Toshio [Central Research Inst. of Electric Power Industry, Komae, Tokyo (Japan). Komae Research Lab.

    1995-06-01

    In the steam generators (SG) of LMFBR, it is necessary to detect the leakage of water from tubes of heat exchangers as soon as it occurs. The active acoustic detection method has drawn general interest owing to its short response time and reduction of the influence of background noise. In this paper, the application of the active acoustic detection method for SG is proposed, and sound attenuation by bubbles is investigated experimentally. Furthermore, using the SG sector model, sound field characteristics and sound attenuation characteristics due to injection of bubbles are studied. It is clarified that the sound attenuation depends upon bubble size as well as void fraction, that the distance attenuation of sound in the SG model containing heat transfer tubes is 6dB for each two-fold increase of distance, and that emitted sound attenuates immediately upon injection of bubbles. (author).

  11. Sensitive hydrogen leak detector

    Science.gov (United States)

    Myneni, Ganapati Rao

    1999-01-01

    A sensitive hydrogen leak detector system using passivation of a stainless steel vacuum chamber for low hydrogen outgassing, a high compression ratio vacuum system, a getter operating at 77.5 K and a residual gas analyzer as a quantitative hydrogen sensor.

  12. The {open_quotes}leak-before-break{close_quotes} applicability in decision support system {open_quotes}strength{close_quotes}

    Energy Technology Data Exchange (ETDEWEB)

    Torop, V.M.; Orynyak, I.V. [Institute for Problems of Strength, Kiev (Ukraine); Kutovoy, O.L. [Institute of Structure Integrity, Kiev (Ukraine)

    1997-04-01

    A software decision support system, STRENGTH, for application of leak before break analysis, is described. The background methodology and sample application are outlined. The program allows multioptional computation of loading parameters for different types of defects, and variable properties for metals and welded joints. Structural strength is assessed, and service life predictions are made. The program is used to analyze specific defects identified by nondestructive testing.

  13. Operational Philosophy Concerning Manned Spacecraft Cabin Leaks

    Science.gov (United States)

    DeSimpelaere, Edward

    2011-01-01

    The last thirty years have seen the Space Shuttle as the prime United States spacecraft for manned spaceflight missions. Many lessons have been learned about spacecraft design and operation throughout these years. Over the next few decades, a large increase of manned spaceflight in the commercial sector is expected. This will result in the exposure of commercial crews and passengers to many of the same risks crews of the Space Shuttle have encountered. One of the more dire situations that can be encountered is the loss of pressure in the habitable volume of the spacecraft during on orbit operations. This is referred to as a cabin leak. This paper seeks to establish a general cabin leak response philosophy with the intent of educating future spacecraft designers and operators. After establishing a relative definition for a cabin leak, the paper covers general descriptions of detection equipment, detection methods, and general operational methods for management of a cabin leak. Subsequently, all these items are addressed from the perspective of the Space Shuttle Program, as this will be of the most value to future spacecraft due to similar operating profiles. Emphasis here is placed upon why and how these methods and philosophies have evolved to meet the Space Shuttle s needs. This includes the core ideas of: considerations of maintaining higher cabin pressures vs. lower cabin pressures, the pros and cons of a system designed to feed the leak with gas from pressurized tanks vs. using pressure suits to protect against lower cabin pressures, timeline and consumables constraints, re-entry considerations with leaks of unknown origin, and the impact the International Space Station (ISS) has had to the standard Space Shuttle cabin leak response philosophy. This last item in itself includes: procedural management differences, hardware considerations, additional capabilities due to the presence of the ISS and its resource, and ISS docking/undocking considerations with a

  14. Glutathione Modified Gold Nanoparticles for Sensitive Colorimetric Detection of Pb(2+) Ions in Rainwater Polluted by Leaking Perovskite Solar Cells.

    Science.gov (United States)

    Yu, Yaming; Hong, Ying; Gao, Peng; Nazeeruddin, Mohammad Khaja

    2016-12-20

    In the past few years, the advent of lead halide perovskite solar cells (PSCs) has revolutionized the prospects of the third- generation photovoltaics and the reported power conversion efficiency (PCE) has been updated to 22%. Nevertheless, two main challenges, including the poisonous content of Pb and the vexing instability toward water, still lie between the lab-based PSCs technology and large scale commercialization. With this background, we first evaluated Pb(2+) concentration from the rainwater samples polluted by three types of markets promising PSCs with inductively coupled plasma mass spectrometry measurements (ICP-MS) as a case study. The influence of possible conditions (pH value and exposure time) on the contents of Pb(2+) from the three PSCs was systematically compared and discussed. Furthermore, an optimized glutathione functionalized gold nanoparticles (GSH-AuNPs) colorimetric sensing assay was used to determine Pb(2+) leaking from PSCs for the first time. The Pb(2+)-induced aggregation of sensing assay could be monitored via both naked eye and UV-vis spectroscopy with a detection limit of 15 and 13 nM, which are all lower than the maximum level in drinking water permitted by WHO. The quantitative detection results were compared and in good agreement with that of ICP-MS. The results indicate that the content of Pb(2+) from three PSCs are in the same order of magnitude under various conditions. By the use of the prepared GSH-AuNPs self-assembled sensing assay, the fast and on-site detection of Pb(2+) from PSCs can be realized.

  15. Endothelial Expression of Endothelin Receptor A in the Systemic Capillary Leak Syndrome.

    Directory of Open Access Journals (Sweden)

    Albert C Sek

    Full Text Available Idiopathic systemic capillary leak syndrome (SCLS is a rare and potentially fatal vascular disorder characterized by reversible bouts of hypotension and edema resulting from fluid and solute escape into soft tissues. Although spikes in permeability-inducing factors have been linked to acute SCLS flares, whether or not they act on an inherently dysfunctional endothelium is unknown. To assess the contribution of endothelial-intrinsic mechanisms in SCLS, we derived blood-outgrowth endothelial cells (BOEC from patients and healthy controls and examined gene expression patterns. Ednra, encoding Endothelin receptor A (ETA-the target of Endothelin 1 (ET-1-was significantly increased in SCLS BOEC compared to healthy controls. Although vasoconstriction mediated by ET-1 through ETA activation on vascular smooth muscle cells has been well characterized, the expression and function of ETA receptors in endothelial cells (ECs has not been described. To determine the role of ETA and its ligand ET-1 in SCLS, if any, we examined ET-1 levels in SCLS sera and functional effects of endothelial ETA expression. ETA overexpression in EAhy926 endothelioma cells led to ET-1-induced hyper-permeability through canonical mechanisms. Serum ET-1 levels were elevated in acute SCLS sera compared to remission and healthy control sera, suggesting a possible role for ET-1 and ETA in SCLS pathogenesis. However, although ET-1 alone did not induce hyper-permeability of patient-derived BOEC, an SCLS-related mediator (CXCL10 increased Edrna quantities in BOEC, suggesting a link between SCLS and endothelial ETA expression. These results demonstrate that ET-1 triggers classical mechanisms of vascular barrier dysfunction in ECs through ETA. Further studies of the ET-1-ETA axis in SCLS and in more common plasma leakage syndromes including sepsis and filovirus infection would advance our understanding of vascular integrity mechanisms and potentially uncover new treatment strategies.

  16. 基于BP神经网络的盘管泄漏检测方法研究%Study of the coil-leak detective method based on the BP neural network

    Institute of Scientific and Technical Information of China (English)

    袁寅; 袁昌明; 王强

    2011-01-01

    proposed that can help us to distinguish between the operation conditions of coil by analyzing various experimental results. In this method, the rapid leakage is detected by BP neural network and the slow leakage is detected by flow balance method with dynamic threshold. With the working conditions changed, it is certain that the BP neural network would generate a signal to the detection system and the dynamic threshold test program is executed to change the original alarming threshold. And, the last but not the least, it is the experimental results that demonstrate that this method is in a position to achieve quite desirable effects in the coil leak detection.%针对单一阈值不能适用于多变工况条件的问题,采用动态阈值修正的流量平衡法与神经网络法相结合的新方法检测反应釜内冷却水盘管泄漏.通过盘管泄漏模拟试验,研究工况变化与泄漏时盘管进出口流量的变化情况.从流量信号中提取盘管泄漏的特征指标构造出神经网络输入矩阵,通过使用大量试验数据对BP神经网络进行训练,对比不同结构的网络训练误差结果,确定其网络结构,建立对盘管运行状况进行分类的BP神经网络模型.试验证明,这种方法能有效检测出盘管泄漏.

  17. Suggestions to leak prevention in Fortaleza's natural gas piping system; Sugestoes para a prevencao de vazamentos de gas natural canalizado na regiao metropolitana de Fortaleza

    Energy Technology Data Exchange (ETDEWEB)

    Teles, Marcus de Barros [Agencia Reguladora de Servicos Publicos Delegados do Estado do Ceara (ARCE), Fortaleza, CE (Brazil)

    2004-07-01

    Leaks are the bigger problem in health, safety and environmental when the subject is gas distribution piping systems. Specially in high density human regions, like in the majority districts of Fortaleza, safety have to be the higher priority to the gas company responsible for the gas distribution piping systems. Leaks are able to cause accidents or incidents, depending on the circumstances which they happen. In order to be control the situation and overcome the luck factor, leaks must be previously avoided by the application of some security requirements. This paper present some suggestions to natural gas leak prevention in the Fortaleza's metropolitan region pipeline systems. First, the piping systems are analysed, observing the risk regions. Then, safety actions and basic requirements to avoid pipe corrosion are presented in order to improve safety in the gas distribution piping systems of Fortaleza's metropolitan region. (author)

  18. Investigating vegetation spectral reflectance for detecting hydrocarbon pipeline leaks from multispectral data

    Science.gov (United States)

    Adamu, Bashir; Tansey, Kevin; Bradshaw, Michael J.

    2013-10-01

    The aim of this paper is to analyse spectral reflectance data from Landsat TM of vegetation that has been exposed to hydrocarbon contamination from oil spills from pipelines. The study is undertaken in an area of mangrove and swamp vegetation where the detection of an oil spill is traditionally difficult to make. We used a database of oil spill records to help identify candidate sites for spectral analysis. Extracted vegetation spectra were compared between polluted and nonpolluted sites and supervised (neural network) classification was carried out to map hydrocarbon (HC) contaminated sites from the sample areas. Initial results show that polluted sites are characterised by high reflectance in the visible (VIS) 0.4μm - 0.7μm, and a lower reflectance in the near-infrared (NIR) 0.7μm - 1.1μm. This suggests that the vegetation is in a stressed state. Samples taken from pixels surrounding polluted sites show similar spectral reflectance values to that of polluted sites suggesting possible migration of HC to the wider environment. Further work will focus on increasing the sample size and investigating the impact of an oil spill on a wider buffer zone around the spill site.

  19. Studied Practices of Helium Mass Spectrometer to Leaking Detection Technology%氦质谱检漏技术的研究与实践

    Institute of Scientific and Technical Information of China (English)

    濮荣强; 黄文平

    2012-01-01

    在氦质谱检漏技术理论的基础上,采用了以微电脑为中心的自动控制技术,提高了氦质谱检漏仪的全自动操作智能化水平.180°非均匀磁场的实现,使离子聚焦更好.通过电子量程切换技术,减少了量程转换时间,扩大了测量范围,对高准确度密封性智能检测系统的实现进行了详细的研究与实践.%Introducing the theoretical basis of helium mass spectrometer to leaking detection technology, the automatic control technology is used here , which improves intelligent level and reduces the range switching time and expands the measuring range with the helps of both 180° non-uniform magnetic field for ion focus and electronic range switching . The paper gives the studied practices to high precision sealed intelligent detection system in detail.

  20. In-service leak testing of district heating systems using dissolved tracer gas. Final report; Betriebsbegleitende Lecksuche mit geloestem Tracergas in Fernwaermesystemen. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Hergarten, A.; Althaus, W. [eds.

    1997-07-31

    The feasibility of in-service leak detection with dissolved tracer gas was investigated. Helium was selected as tracer gas because of its good diffusion characteristics, selective detectability at very low concentrations, inert and unproblematic behaviour within the district heating system, and good environmental compatibility. For a systematic investigation of the influencing parameters governing practical applications, a pipeline test field comprising about 240 m of KMR district heating pipelines and 61 controllable simulation leaks was constructed, and experiments using the new method were carried out. The required helium concentration amounts to a few grams of helium per cubic metre of district heating water. The water can be charged in the water preparation or feeding stage, and commercial detectors can be used. (orig./GL) [Deutsch] Zur Entwicklung einer betriebsbegleitenden Lecksuchmethode fuer erdverlegte Rohrleitungen wurden in einem Feasbility-Test die Machbarkeit der Tracergassuche mittels geloestem Spuergas bestaetigt. Als Tracergas wurde Helium aufgrund seines guenstigen Diffusionsverhaltens, seiner selektiven Nachweisbarkeit bei kleinsten Konzentrationen, seines inerten, unproblematischen Verhaltens im Fernwaermenetz und seiner guten Umweltvertraeglichkeit ausgewaehlt. Zur systematischen Untersuchung der Einflussparameter bei der Anwendung der Methode unter praxisnahen Bedingungen wurde ein Rohrleitungsversuchsfeld mit ca. 240 m KMR-Fernwaermeleitung und 61 regelbaren Simulationsleckagen aufgebaut und die neue Lecksuchmethode eingehend experimentell getestet. Die einzustellende Heliumkonzentration im Fernwaermewasser ist mit wenigen Gramm Helium je Kubikmeter Fernwaermewasser gering. Eine Vorrichtung fuer die empfohlene Beladung des gesamten Netzwasserinhalts kann in Wasseraufbereitung oder Nachspeisung des Netzes eingebunden werden. Zur Detektion koennen, marktverfuegbare Messgeraete verwendet werden. (orig./GL)

  1. Identification of sewage leaks by active remote-sensing methods

    Science.gov (United States)

    Goldshleger, Naftaly; Basson, Uri

    2016-04-01

    The increasing length of sewage pipelines, and concomitant risk of leaks due to urban and industrial growth and development is exposing the surrounding land to contamination risk and environmental harm. It is therefore important to locate such leaks in a timely manner, to minimize the damage. Advances in active remote sensing Ground Penetrating Radar (GPR) and Frequency Domain Electromagnetic (FDEM) technologies was used to identify leaking potentially responsible for pollution and to identify minor spills before they cause widespread damage. This study focused on the development of these electromagnetic methods to replace conventional acoustic methods for the identification of leaks along sewage pipes. Electromagnetic methods provide an additional advantage in that they allow mapping of the fluid-transport system in the subsurface. Leak-detection systems using GPR and FDEM are not limited to large amounts of water, but enable detecting leaks of tens of liters per hour, because they can locate increases in environmental moisture content of only a few percentage along the pipes. The importance and uniqueness of this research lies in the development of practical tools to provide a snapshot and monitoring of the spatial changes in soil moisture content up to depths of about 3-4 m, in open and paved areas, at relatively low cost, in real time or close to real time. Spatial measurements performed using GPR and FDEM systems allow monitoring many tens of thousands of measurement points per hectare, thus providing a picture of the spatial situation along pipelines and the surrounding. The main purpose of this study was to develop a method for detecting sewage leaks using the above-proposed geophysical methods, since their contaminants can severely affect public health. We focused on identifying, locating and characterizing such leaks in sewage pipes in residential and industrial areas.

  2. Test Plan for the Demonstration of Geophysical Techniques for Single-Shell Tank Leak Detection at the Hanford Mock Tank Site: Fiscal Year 2001

    Energy Technology Data Exchange (ETDEWEB)

    Barnett, D. Brent; Gee, Glendon W.; Sweeney, Mark D.

    2001-07-31

    As part of the Leak Detection, Monitoring and Mitigation (LDMM) program conducted by CH2M HILL 105-A during FY 2001. These tests are being conducted to assess the applicability of these methods (Electrical Resistance Tomography [ERT], High Resolution Resistivity [HRR], Cross-Borehole Seismography [XBS], Cross-Borehole Radar [XBR], and Cross-Borehole Electromagnetic Induction [CEMI]) to the detection and measurement of Single Shell Tank (SST) leaks into the vadose zone during planned sluicing operations. The testing in FY 2001 will result in the selection of up to two methods for further testing in FY 2002. In parallel with the geophysical tests, a Partitioning Interwell Tracer Test (PITT) study will be conducted simultaneously at the Mock Tank to assess the effectiveness of this technology in detecting and quantifying tank leaks in the vadose zone. Preparatory and background work using Cone Penetrometer methods (CPT) will be conducted at the Mock Tank site and an adjacent test area to derive soil properties for groundtruthing purposes for all methods.

  3. Anastomotic leaks after bariatric surgery: it is the host response that matters.

    Science.gov (United States)

    Al-Sabah, Salman; Ladouceur, Martin; Christou, Nicolas

    2008-01-01

    Anastomotic leaks after bariatric surgery can lead to severe complications and adverse outcomes. We tested the hypothesis that not all patients with an anastomotic leak after bariatric surgery present with clinical symptoms and that their outcome is dependent on the aggressiveness of the host inflammatory response. This was a retrospective analysis of prospectively collected clinical data from 2384 bariatric surgeries from 1983 to 2006. All anastomotic leaks were identified from the database, and the vital signs, hematologic and biochemical data, mode of diagnosis, treatment, and outcome were recorded and analyzed. We identified 55 anastomotic leaks (2.3%) at a median of 4 days (range 1-26) after surgery. In 37 patients (67.3%), the leaks were identified at a median of 5 days (range 1-26) postoperatively because of clinical signs and symptoms of a systemic inflammatory response (SIRS leaks). In contrast, in 18 patients (32.7%), the leaks were identified at a median of 1.5 days (range 1-16) postoperatively only after routine contrast studies (non-SIRS leaks). Treatment included antibiotics and open drainage in 41.8%, laparoscopic drainage in 21.8%, computed tomography-guided drainage in 12.7%, conservative treatment in 14.5%, and other in 9.2%. All 6 deaths (4 men and 2 women, 10.9%) occurred in the SIRS group. Using logistic regression analysis, temperature (inflammatory response) and body mass index were independent predictors of mortality. The results of our study have shown that one third of patients with anastomotic leaks after bariatric surgery present with minimal clinical symptoms (non-SIRS) and are only detected if contrast studies are performed. Such leaks are unlikely to lead to death. Two thirds of patients with anastomotic leaks present with a systemic inflammatory response to the leak. Such leaks require urgent treatment that might not always prevent death.

  4. Tetracycline-controlled transcriptional regulation systems:countermeasures to eliminate basal transgene leaks in Tet-based systems

    Institute of Scientific and Technical Information of China (English)

    XIAO Dong; SUN Yan; GU Weiwang; CHEN Xigu

    2007-01-01

    To analyze the function of any given transgene(s) accurately in transgenic mice, and to produce credible transgenic animal models of various human diseases (precisely and realistically mimicking disease states), it is critical to be able to control gene expression in the animals conditionally. The ability to switch gene expression "on" or "off" in the restricted cells or tissue(s) at specific time(s)allows unprecedented flexibility for exploring gene function(s) in both the health and the disease. Pioneering work on inducible transgene expression has led to the development of a wide variety of controlled gene expression systems that meet this criterion. Among them, the tetracycline-inducible systems (e. g. Tet-off and Tet-on) have been widely, frequently and successfully employed in vitro and in vivo.These systems, however, are not always tight but leaky; sometimes the leakage is significant. In some circumstances, the resulting leak is acceptable, but in others, it is more problematic. Though these systems face this disadvantage, i.e. basal transgene leakage in vitro and in vivo, several approaches, including using improved versions (e. g. rtTA2S-M2 and rtTA2S-S2) of rtTA, tetracycline-controlled transcriptional silencer (tTS), an "ideal" minimal promoter in responsive components or combinations thereof, have been developed to avoid this limitation effectively. In this review we discuss the countermeasures available to eliminate basal transgene leakage from Tet-based systems.

  5. Current dependence of heat leak on the terminals in the superconducting DC transmission and distribution system of CASER-2

    Science.gov (United States)

    Kawahara, Toshio; Watanabe, Hirofumi; Emoto, Masahiko; Hamabe, Makoto; Yamaguchi, Sataro; Hikichi, Yasuo; Minowa, Masahiro

    2012-12-01

    Superconductivity can solve the energy problems in the world as energy saving technologies. In particular, superconducting direct current (DC) transmission and distribution (T&D) systems is promising, as it can be easily extended to large scale energy transmission systems for energy sharing. We are developing criogenic systems for effective cooling of superconducting T&D systems. In the cooling experiments with the 200 m-class superconducting DC T&D system at Chubu University (CASER-2), we have estimated the performance of the system. For example, our superconducting cable is connected to the outside at the terminals using Peltier current leads (PCLs). The PCL is composed of a thermoelectric material and a copper lead. Small thermal conductivity and large thermopower of the thermoelectric modules can effectively insulate the heat leak to the low temperature end. We measured the temperature along the current leads and the heat leak at the terminals. As current leads have an optimal shape factor, the optimum operation current exists. The current dependence of the system performance is discussed.

  6. In-service helium leak testing of vacuum furnace

    Science.gov (United States)

    Ahmad, Anis; Tripathi, S. K.; Sawant, P. S.; Mukharjee, D.; Shah, B. K.

    2012-11-01

    Helium leak detection of vacuum furnaces and equipments used for processing of nuclear material is generally carried out by utilizing vacuum spray technique. In this technique helium leak detector is connected to the furnace, back ground reading is noted and helium gas is sprayed on all the suspected joints. Any increase in back ground is noted as leak signal. Processing of Zirconium alloy cladded fuel pins is carried out in vacuum furnace of about 3 meter length and 500 mm inside diameter. Furnace is connected with two numbers of rotary vacuum pump and one number of diffusion pump for creating vacuum (1 × 10-6 torr) inside the furnace. It is desirable that furnace should have good vacuum and best possible leak tightness during dynamic and static vacuum. During dynamic vacuum at higher temperature although required vacuum is achieved the furnace may have fine leakage through which air may enter and cause oxidation of clad tube leading to change in its coloration. This change in coloration will cause rejection of fuel element. Such fine leakages may not be reflected in the dynamic vacuum of the system at high temperature. During trial run change in coloration of outside surface of clad tube was observed although dynamic vacuum of the furnace was in the range of 1×10-6 torr range. To eliminate such possibilities of oxidation due to fine leakages in the system, it was decided to carry out in-service leak testing of the furnace. Helium leak testing of the furnace was carried out by using vacuum spray method and leaks observed were repaired and furnace was retested to ensure the leak tightness. The in-service helium leak testing of the furnace helped in maintaining its leak tightness during service under dynamic vacuum and prevent oxidation of fuel element. This paper describes the techniques of in- service helium leak testing, it's importance for detection of fine leak under dynamic vacuum and discusses details of the testing method and result obtained.

  7. C/C ++program memory leak detection based on bounded model checking%基于有界模型检测的C/C++程序内存泄露检测

    Institute of Scientific and Technical Information of China (English)

    黄蔚; 洪玫; 杨秋辉; 郭鑫宇; 代声馨; 徐保平; 高婉玲; 赵鹤

    2016-01-01

    The dynamic memory management mechanism in C /C ++programming language is free and flexible,but when used by developer it is easy to introduce memory leaks which lead to performance degradation and even failure of system.In order to detect memory leak more effectively,this paper proposed a memory leak detection method based on bounded model checking for C program called MLD-CBMC.It took C /C ++program files as input,unwound the program and inserted memory leak proper-ties,encoded the program constraints and properties into verification conditions using satisfiability modulo theory,then passed the verification conditions to a SMT solver.Thus it converted detecting memory leaks to solving satisfiability problems.By ex-periment and cooperation with other bounded model checking tools,MLD-CBMC shows its feasibility and effectiveness.%C /C ++语言中的动态内存管理机制自由且灵活,但动态内存的使用容易引入内存泄露,导致系统性能降低甚至系统崩溃。为了更加有效地检测内存泄露,提出了一个基于有界模型检测技术的 C /C ++程序内存泄露检测方案 MLD-CBMC。该方案以 C /C ++程序文件为输入,利用有界模型检测技术对程序进行展开处理,加入内存泄露性质,并利用可满足性模理论(SMT)对程序约束和性质组成的验证条件编码,使用 SMT 求解器对验证条件求解,将检测内存泄露问题转换为求解可满足性问题,实现 C /C ++程序内存泄露的检测。通过实验验证了方案的有效性,并与其他有界模型检测工具进行对比实验,实验证明方案对内存泄露的检测能力更强。

  8. Dimensionality aspects of nano micro integrated metal oxide based early stage leak detection room temperature hydrogen sensor

    Science.gov (United States)

    Deshpande, Sameer Arun

    Detection of explosive gas leaks such as hydrogen (H2) becomes key element in the wake of counter-terrorism threats, introduction of hydrogen powered vehicles and use of hydrogen as a fuel for space explorations. In recent years, a significant interest has developed on metal oxide nanostructured sensors for the detection of hydrogen gas. Gas sensors properties such as sensitivity, selectivity and response time can be enhanced by tailoring the size, the shape, the structure and the surface of the nanostructures. Sensor properties (sensitivity, selectivity and response time) are largely modulated by operating temperature of the device. Issues like instability of nanostructures at high temperature, risk of hydrogen explosion and high energy consumption are driving the research towards detection of hydrogen at low temperatures. At low temperatures adsorption of O2- species on the sensor surface instead of O- (since O- species reacts easily with hydrogen) result in need of higher activation energy for hydrogen and adsorbed species interaction. This makes hydrogen detection at room temperature a challenging task. Higher surface area to volume ratio (resulting higher reaction sites), enhanced electronic properties by varying size, shape and doping foreign impurities (by modulating space charge region) makes nanocrystalline materials ideal candidate for room temperature gas sensing applications. In the present work various morphologies of nanostructured tin oxide (SnO 2) and indium (In) doped SnO2 and titanium oxide (titania, TiO2) were synthesized using sol-gel, hydrothermal, thermal evaporation techniques and successfully integrated with the micro-electromechanical devices H2 at ppm-level (as low as 100ppm) has been successfully detected at room temperature using the SnO2 nanoparticles, SnO2 (nanowires) and TiO2 (nanotubes) based MEMS sensors. While sensor based on indium doped tin oxide showed the highest sensitivity (S =Ra/Rg= 80000) and minimal response time (10sec

  9. Non-invasive detection of biliary leaks using Gd-EOB-DTPA-enhanced MR cholangiography: comparison with T2-weighted MR cholangiography

    Energy Technology Data Exchange (ETDEWEB)

    Kantarci, Mecit; Pirimoglu, Berhan; Bayraktutan, Ummugulsum; Ogul, Hayri; Kizrak, Yesim; Eren, Suat [Atatuerk University, School of Medicine, Department of Radiology, Erzurum (Turkey); Karabulut, Nevzat [Pamukkale University, School of Medicine, Department of Radiology, Denizli (Turkey); Ozturk, Gurkan; Aydinli, Bulent [Atatuerk University, School of Medicine, Department of General Surgery, Erzurum (Turkey); Yilmaz, Sinan [Atatuerk University, School of Medicine, Department of Public Health, Erzurum (Turkey)

    2013-10-15

    To evaluate the added role of T1-weighted (T1w) gadolinium ethoxybenzyl diethylenetriamine penta-acetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance cholangiography (MRC) compared with T2-weighted MRC (T2w-MRC) in the detection of biliary leaks. Ninety-nine patients with suspected biliary complications underwent routine T2w-MRC and T1w contrast-enhanced (CE) MRC using Gd-EOB-DTPA to identify biliary leaks. Two observers reviewed the image sets separately and together. MRC findings were compared with those of surgery and percutaneous transhepatic cholangiopancreatography. The sensitivity, specificity and accuracy of the techniques in identifying biliary leaks were calculated. Accuracy of locating biliary leaks was superior with the combination of Gd-EOB-DTPA-enhanced MRC and T2w-MRC (P < 0.05).The mean sensitivities were 79 % vs 59 %, and the mean accuracy rates were 84 % vs 58 % for combined CE-MRC and T2w-MRC vs sole T2w-MRC. Nineteen out of 21 patients with biliary-cyst communication, 90.4 %, and 12/15 patients with post-traumatic biliary extravasations, 80 %, were detected by the combination of Gd-EOB-DTPA-enhanced MRC and T2w-MRC images, P < 0.05. Gd-EOB-DTPA-enhanced MRC yields information that complements T2w-MRC findings and improves the identification and localisation of the bile extravasations (84 % accuracy, 100 % specificity, P < 0.05). We recommend Gd-EOB-DTPA-enhanced MRC in addition to T2w-MRC to increase the preoperative accuracy of identifying and locating extravasations of bile. (orig.)

  10. Systemic Capillary Leak Syndrome associated with hypovolemic shock and compartment syndrome. Use of transpulmonary thermodilution technique for volume management

    Directory of Open Access Journals (Sweden)

    Schmid Roland M

    2010-07-01

    Full Text Available Abstract Systemic Capillary Leak Syndrome (SCLS is a rare disorder characterized by increased capillary hyperpermeability leading to hypovolemic shock due to a markedly increased shift of fluid and protein from the intravascular to the interstitial space. Hemoconcentration, hypoalbuminemia and a monoclonal gammopathy are characteristic laboratory findings. Here we present a patient who suffered from SCLS with hypovolemic shock and compartment syndrome of both lower legs and thighs. Volume and catecholamine management was guided using transpulmonary thermodilution. Extended hemodynamic monitoring for volume and catecholamine management as well as monitoring of muscle compartment pressure is of crucial importance in SCLS patients.

  11. Reduction of the heat leak in superconducting system at half-wave-rectified current mode by peltier current lead

    CERN Document Server

    Yamaguchi, T; Nakamura, K; Yamaguchi, S; Hasegawa, Y

    2002-01-01

    Experiments of Peltier current lead (PCL) were performed by the way of half-wave-rectified current (HWRC) for an evaluation of the PCL system in the drive with the large-rippled current. The current ripple of the HWRC is large, and we discussed the cooling capability of the current ripple. The experimental results revealed that the temperature difference of the thermoelectric-element (TE) increased with the magnitude of the current in the PCL system, despite the large current ripple. Calorimetric measurements revealed that the PCL reduced the heat leak of 60% for the peak current 90A. We compared the PCL systems of the direct current (dc) mode and the HWRC mode. The results showed that the current dependence of the temperature difference in the HWRC mode did not match that of the dc mode, but those of the heat leak matched well. The performance of the Peltier cooling in the HWRC mode is reduced to be 2/pi time of the Seebeck coefficient for the dc mode by using the time-average method. (author)

  12. Reduction of the heat leak in superconducting system at half-wave-rectified current mode by peltier current lead

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Takayuki; Ohtaki, Naohiro; Nakamura, Keiji; Yamaguchi, Satarou [Chubu Univ., Kasugai, Aichi (Japan); Hasegawa, Yasuhiro [Saitama Univ., Saitama (Japan)

    2002-09-01

    Experiments of Peltier current lead (PCL) were performed by the way of half-wave-rectified current (HWRC) for an evaluation of the PCL system in the drive with the large-rippled current. The current ripple of the HWRC is large, and we discussed the cooling capability of the current ripple. The experimental results revealed that the temperature difference of the thermoelectric-element (TE) increased with the magnitude of the current in the PCL system, despite the large current ripple. Calorimetric measurements revealed that the PCL reduced the heat leak of 60% for the peak current 90A. We compared the PCL systems of the direct current (dc) mode and the HWRC mode. The results showed that the current dependence of the temperature difference in the HWRC mode did not match that of the dc mode, but those of the heat leak matched well. The performance of the Peltier cooling in the HWRC mode is reduced to be 2/{pi} time of the Seebeck coefficient for the dc mode by using the time-average method. (author)

  13. JavaScript 中的内存泄漏检测方法研究磁%An Approach to Detection Memory Leak in JavaScript

    Institute of Scientific and Technical Information of China (English)

    孙琳; 洪玫; 詹聪; 杜伊; 张琼宇

    2015-01-01

    As a mainstream front‐end script language ,JavaScript is widely used in WEB applications .Although dynam‐ic memory management for JavaScript is to use automatic management methods ,it still has memory leak problem because of the use of all kinds of libraries .In this paper ,11 kinds of memory leak patterns are analyzed and summarized ,it put forward combining the dynamic and static detection methods ,which implements the 11 kinds of memory leak detection .For static de‐tection ,abstract syntax tree is created based on JavaScript program ,relationship between class and event is analyzed and ab‐stracted ,object execution trajectory is tracked ,the suspected leak objects are found .For dynamic detection ,according to the result of static detection ,test cases are generated and ran ,dynamic heap information is gotten ,type points‐from graph is cre‐ated ,memory leaks is judged by analyzing rising trend of memory usage rate .This memory leak detection method is feasible by experimental verification ,performing well ,which reduces false positives compared with static detection and increases cov ‐erage rate compared with dynamic detection .%JavaScript 作为一种主流的前端脚本语言,广泛运用于 Web 应用中。虽然 JavaScript 语言具有垃圾回收机制动态管理内存,但用于各类程序库的的运用,仍然存在内存泄漏的问题。论文分析和归纳了十一种内存泄漏的模式,并提出静态和动态的检测方法的结合,实现对十一种内存泄漏的检测。在静态检测中,基于 JavaScript 程序的抽象语法树,分析和抽象类和事件之间的关系,跟踪对象执行轨迹,发现疑似泄漏的对象。在动态检测阶段,依据静态检测结果,生成测试用例并运行,获取动态堆信息,构建类型指向图,通过分析内存占用率上升的趋势判断内存泄漏。实验验证本内存泄漏检测方法是可行性的,并有较好的检测能力,比较

  14. [Clinical analysis of 34 cases with sepsis and systemic capillary leak syndrome].

    Science.gov (United States)

    Ma, H X; Shi, X J; Liang, Y R; Shi, H D; Wang, H; Zhao, Y S

    2017-09-01

    Objective: To study the clinical characteristics of sepsis with systemic capillary leak syndrome(SCLS) and to evaluate the therapeutic effect and clinical significance of fluid therapy adjusted timely in these patients. Methods: The clinical data of 34 patients with sepsis and SCLS in the Department of Hepatobiliary Surgery ICU of General Hospital of People's Liberation Army General Hospital from July 2014 to January 2016 were retrospectively analyzed.There were 21 males and 13 females, aged from 21 to 74 years, with an average age of 56.3 years.Primary disease as follows: 18 cases with severe acute pancreatitis, 7 postoperative cases of subtotal hepatectomy, 5 postoperative cases of pancreatoduodenectomy, 4 postoperative cases of cholelithiasis.These patients were divided into survival group and death group according to their 28-day survival status.The clinical data including C-reactive protein(CRP), platelets (PLT), brain natriuretic peptide (BNP), the level of arterial blood lactic acid(LAC), oxygenation index(PaO2/FiO2, OI), net fluid balance(NFB) and norepinephrine dosage(NE) were collected and compared between two groups at three different intervals(day 1-3, day 4-6, day 7-9). The measurement data and numeration data were statistically analyzed with t test and χ(2) test respectively to explore the inherent characteristics of the disease evolution and its clinical significance. Results: The survival group (n=23)and the death group(n=11)had no significant difference in the characteristics of basic clinical characters.The condition of the survival group and the death group were both in progress in 1-3 days period manifested as increased CRP(t=-0.473, P=0.640) and BNP levels(t=0.140, P=0.895), decreased PLT counts(t=-0.505, P=0.620) in the inflammatory response, decreased LAC(t=-1.008, P=0.320) and OI level (t=-2.379, P=0.020)in tissue perfusion index, and positive fluid balance(NFB: t=0.910, P=0.370), required NE(t=-0.853, P=0.400) to maintain effective

  15. Influence of Crack Morphology on Leak Before Break Margins

    Energy Technology Data Exchange (ETDEWEB)

    Weilin Zang (Inspecta Technology AB, Stockholm (SE))

    2007-11-15

    The purpose of the project is to evaluate the deterministic LBB-margins for different pipe systems in a Swedish PWR-plant and using different crack morphology parameters. Results: - The influence of crack morphology on Leak Before Break (LBB) margins is studied. The subject of the report is a number of LBB-submittals to SKI where deterministic LBB-margins are reported. These submittals typically uses a surface roughness of 0.0762 mm (300 microinch) and number of turns equal to zero and an in-house code for the leak rate evaluations. The present report has shown that these conditions give the largest LBB-margins both in terms of the quotient between the critical crack length and the leakage crack size and for the leak rate margin. - Crack morphology parameters have a strong influence on the leak rate evaluations. Using the SQUIRT code and more recent recommendations for crack morphology parameters, it is shown that in many cases the evaluated margins, using 1 gpm as the reference leak rate detection limit, are below the safety factor of 2 on crack size and 10 on leak rate, which is generally required for LBB approval. - The effect of including weld residual stresses on the LBB margins is also investigated. It is shown that for the two examples studied, weld residual stresses were important for the small diameter thin wall pipe whereas it was negligible for the large diameter thick wall pipe which had a self-balanced weld residual stress distribution

  16. Variable leak gas source

    Science.gov (United States)

    Henderson, Timothy M.; Wuttke, Gilbert H.

    1977-01-01

    A variable leak gas source and a method for obtaining the same which includes filling a quantity of hollow glass micro-spheres with a gas, storing said quantity in a confined chamber having a controllable outlet, heating said chamber above room temperature, and controlling the temperature of said chamber to control the quantity of gas passing out of said controllable outlet. Individual gas filled spheres may be utilized for calibration purposes by breaking a sphere having a known quantity of a known gas to calibrate a gas detection apparatus.

  17. System of leak inspection of irradiated fuel; Sistema de inspeccion de fuga de combustible irradiado

    Energy Technology Data Exchange (ETDEWEB)

    Delfin L, A.; Castaneda J, G.; Mazon R, R.; Aguilar H, F. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico)]. e-mail: rmr@nuclear.inin.mx

    2007-07-01

    The International Atomic Energy Agency (IAEA) through the project RLA/04/18 Irradiated Fuel Management in Research reactors, recommended among other that the participant countries (Brazil, Argentina, Chile, Peru and Mexico), develop the sipping tool to generate registrations of the state that keep the irradiated fuels in the facilities of each country. The TRIGA Mark lll Reactor (RTMIII) Department, generated a project that it is based on the dimensions of the used fuel by the RTMIII, for design and to build an inspection system of irradiated fuel well known as SIPPING. This technique, provides a high grade of accuracy in the detection of gassy fission products or liquids that escape from the enveloping of fuels that have flaws or flights. The operation process of the SIPPING is carried out generating the migration of fission products through the creation of a pressure differential gas or vacuum to identify fuel assemblies failed by means of the detection of the xenon and/or krypton presence. The SIPPING system, is a device in revolver form with 4 tangential nozzles, which will discharge the fluid between the external surface of the enveloping of the fuel and the interior surface of the encircling one; the device was designed with independent pieces, with threaded joining and with stamps to impede flights of the fluid toward the exterior of the system. The System homogenizes and it distributes the fluid pressure so that the 4 nozzles work to equality of conditions, for what the device was designed in 3 pieces, an internal that is denominated revolver, one external that calls cover, and a joining called mamelon that will unite with the main encircling of the system. The detection of fission products in failed fuels, its require that inside the encircling one where the irradiated fuel element is introduced, be generated a pressure differential of gas or vacuum, and that it allows the samples extraction of water. For what generated a top for the encircling with the

  18. In-pipe leak detection by Minimum Residual complexity: A Robust time Delay Estimation method against correlated noise

    CERN Document Server

    Ahmadi, A M; Bahrampour, A R; Ravanbod, H

    2013-01-01

    In this work, the residual complexity (RC) similarity measure, is employed for time delay estimation (TDE) in gas pipe leak localization. The result of TDE by RC is compared with those of Cross Correlation(CC) and Mutual Information(MI) similarity measures based on our experimental data. The comparison confirms the advantages of RC relative to CC and MI, in robustness against both correlated noises and reduction of number of samples. These advantages originate from not only its mathematical nature of RC similarity measure which considers interdependency but also from broadband frequency of acoustic waves propagating during gas pipes.

  19. Locating a leaking crack by safe stimulation

    Energy Technology Data Exchange (ETDEWEB)

    Coleman, C.E.; Sagat, S. (Atomic Energy of Canada Ltd., Chalk River, ON (Canada). Chalk River Nuclear Labs.); Shek, G.K.; Graham, D.B.; Durand, M.A. (Ontario Hydro, Toronto, ON (Canada))

    1990-01-01

    A few Zr-2.5 Nb alloy pressure tubes in CANDU nuclear reactors have leaked through cracks that have grown by delayed hydride cracking (DHC). In some instances, tubes contained confirmed leaks that were leaking at a rate too low for precise identification of the leaking channel. Controlled stimulation of DHC can be used to help locate these leaks by extending the crack and increasing the leak rate without approaching crack instability. In the event of a leak being detected, a plant operator can gain time for leak location by a heating and unloading manoeuvre that will arrest crack growth and increase the critical crack length. This manoeuvre increases the safety margin against tube rupture. If required, the operator can then stimulate cracking in a controlled manner to aid in leak identification. Sequences of temperature and load manoeuvres for safe crack stimulation have been found by laboratory tests on dry specimens and the efficacy of the process has been demonstrated, partly in a power reactor, and partly in a full-scale simulation of a leaking pressure tube. (author).

  20. System for leaks inspection in a nuclear plant by means of a mobile robot; Sistema para inspeccion de fugas en una planta nuclear por medio de un robot movil

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez S, R.; Segovia de los Rios, J.A. [ININ, Km. 36.5 Carretera Mexico-Toluca, Salazar, Edo. de Mexico (Mexico)]. E-mail: ramses@nuclear.inin.mx

    2004-07-01

    In this work a supervision system that could allow to carry out the detection of leaks of vapor in pipe lines, using a mobile robot Pioneer 2 -D Xe, which is controlled by means of an external micro controller 68HC912B32 programmed in Forth and using diffuse control to travel a road by means of the one to follow one lines painted in the floor is described. The robot takes in his superior part, a thermographic camera that allows to determine if leaks of vapor exist in pipes and a dosemeter to measure the present radiation levels in the place, besides a video camera. This way, the personnel, can make sure of having a propitious situation to make the maintenance of the facilities. (Author)

  1. Leak before break application in French PWR plants under operation

    Energy Technology Data Exchange (ETDEWEB)

    Faidy, C. [EDF SEPTEN, Villeurbanne (France)

    1997-04-01

    Practical applications of the leak-before break concept are presently limited in French Pressurized Water Reactors (PWR) compared to Fast Breeder Reactors. Neithertheless, different fracture mechanic demonstrations have been done on different primary, auxiliary and secondary PWR piping systems based on similar requirements that the American NUREG 1061 specifications. The consequences of the success in different demonstrations are still in discussion to be included in the global safety assessment of the plants, such as the consequences on in-service inspections, leak detection systems, support optimization,.... A large research and development program, realized in different co-operative agreements, completes the general approach.

  2. Design and experimentation of a bell-mouthed spray gun with two channels for helium leak detection%一种氦质谱检漏用双流道喷枪的设计及实验

    Institute of Scientific and Technical Information of China (English)

    冯晓; 廖旭东; 胡茂中; 白国云; 陈涛

    2012-01-01

    To solve the problem of inaccurate positioning of leak by usual spray gun during the leak detection, a bell-mouthed spay gun with two channels was designed and the corresponding experiment was also carried out. The results show that the bell-mouthed spray gun with two channels can differentiate the two leaks 15mm apart and the positioning range of single leak is Φ20mm, which improves the accuracy of leak positioning during helium leak detection.%为解决普通喷枪在检漏时对漏孔定位能力低的问题,设计了一种钟罩式双流道喷枪,并对其开展了测试实验.结果表明:喷氦法检漏时,利用钟罩式双流道喷枪可分辨出相距15mm的相邻漏孔,对单一漏孔定位范围为Φ20 mm,较大的提高了喷氦法检漏时对漏孔的定位能力.

  3. Dual-tree complex wavelet transform and SVD based acoustic noise reduction and its application in leak detection for natural gas pipeline

    Science.gov (United States)

    Yu, Xuchao; Liang, Wei; Zhang, Laibin; Jin, Hao; Qiu, Jingwei

    2016-05-01

    During the last decades, leak detection for natural gas pipeline has become one of the paramount concerns of pipeline operators and researchers across the globe. However, acoustic wave method has been proved to be an effective way to identify and localize leakage for gas pipeline. Considering the fact that noises inevitably exist in the acoustic signals collected, noise reduction should be enforced on the signals for subsequent data mining and analysis. Thus, an integrated acoustic noise reduction method based on DTCWT and SVD is proposed in this study. The method is put forward based on the idea that noise reduction strategy should match the characteristics of the noisy signal. According to previous studies, it is known that the energy of acoustic signals collected under leaking condition is mainly concentrated in low-frequency portion (0-100 Hz). And ultralow-frequency component (0-5 Hz), which is taken as the characteristic frequency band in this study, can propagate a relatively longer distance and be captured by sensors. Therefore, in order to filter the noises and to reserve the characteristic frequency band, DTCWT is taken as the core to conduct multilevel decomposition and refining for acoustic signals and SVD is employed to eliminate noises in non-characteristic bands. Both simulation and field experiments show that DTCWT-SVD is an excellent method for acoustic noise reduction. At the end of this study, application in leakage localization shows that it becomes much easier and a little more accurate to estimate the location of leak hole after noise reduction by DTCWT-SVD.

  4. Leak-Tight Welding Experience from the Industrial Assembly of the LHC Cryostats at CERN

    CERN Document Server

    Bourcey, N; Chiggiato, P; Limon, P; Mongelluzzo, A; Musso, G; Poncet, A; Parma, V

    2008-01-01

    The assembly of the approximately 1700 LHC main ring cryostats at CERN involved extensive welding of cryogenic lines and vacuum vessels. More than 6 km of welding requiring leak tightness to a rate better than 1.10-9 mbar.l.s-1 on stainless steel and aluminium piping and envelopes was made, essentially by manual welding but also making use of orbital welding machines. In order to fulfil the safety regulations related to pressure vessels and to comply with the leak-tightness requirements of the vacuum systems of the machine, welds were executed according to high qualification standards and following a severe quality assurance plan. Leak detection by He mass spectrometry was extensively used. Neon leak detection was used successfully to locate leaks in the presence of helium backgrounds. This paper presents the quality assurance strategy adopted for welds and leak detection. It presents the statistics of non-conformities on welds and leaks detected throughout the entire production and the advances in the use...

  5. Interior intrusion detection systems

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, J.R.; Matter, J.C. (Sandia National Labs., Albuquerque, NM (United States)); Dry, B. (BE, Inc., Barnwell, SC (United States))

    1991-10-01

    The purpose of this NUREG is to present technical information that should be useful to NRC licensees in designing interior intrusion detection systems. Interior intrusion sensors are discussed according to their primary application: boundary-penetration detection, volumetric detection, and point protection. Information necessary for implementation of an effective interior intrusion detection system is presented, including principles of operation, performance characteristics and guidelines for design, procurement, installation, testing, and maintenance. A glossary of sensor data terms is included. 36 figs., 6 tabs.

  6. Interior intrusion detection systems

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, J.R.; Matter, J.C. (Sandia National Labs., Albuquerque, NM (United States)); Dry, B. (BE, Inc., Barnwell, SC (United States))

    1991-10-01

    The purpose of this NUREG is to present technical information that should be useful to NRC licensees in designing interior intrusion detection systems. Interior intrusion sensors are discussed according to their primary application: boundary-penetration detection, volumetric detection, and point protection. Information necessary for implementation of an effective interior intrusion detection system is presented, including principles of operation, performance characteristics and guidelines for design, procurement, installation, testing, and maintenance. A glossary of sensor data terms is included. 36 figs., 6 tabs.

  7. EXPLORING ANTECEDENT ENVIRONMENTAL AND ORGANIZATIONAL FACTORS TO USER-CAUSED INFORMATION LEAKS: A QUALITATIVE STUDY : 20. European Conference on Information Systems (ECIS 2012)

    NARCIS (Netherlands)

    Hadasch, Frank; Mueller, Benjamin; Maedche, Alexander

    2012-01-01

    Sensitive company information can leak to unauthorized parties in case employees do not perform effective protective measures while using application systems for their day-to-day tasks. To reduce the risks for such information leakage incidents, many companies oblige employees to follow information

  8. ISOLDE Off-line Gas Leak Upgrade

    CERN Document Server

    Nielsen, Kristoffer Bested

    2017-01-01

    This study investigates gas injection system of the ISOLDE Off-line separator. A quadrupole mass spectrometer is used to analysis the composition of the gas. Based on these measurements a contamination of the injected gas is found and a system upgrade is purposed. Furthermore a calibration of the leak rate of the leak valve is made.

  9. Failure detection of liquid cooled electronics in sealed packages. [in airborne information management system

    Science.gov (United States)

    Hoadley, A. W.; Porter, A. J.

    1991-01-01

    The theory and experimental verification of a method of detecting fluid-mass loss, expansion-chamber pressure loss, or excessive vapor build-up in NASA's Airborne Information Management System (AIMS) are presented. The primary purpose of this leak-detection method is to detect the fluid-mass loss before the volume of vapor on the liquid side causes a temperature-critical part to be out of the liquid. The method detects the initial leak after the first 2.5 pct of the liquid mass has been lost, and it can be used for detecting subsequent situations including the leaking of air into the liquid chamber and the subsequent vapor build-up.

  10. LOCATING LEAKS WITH ACOUSTIC TECHNOLOGY

    Science.gov (United States)

    Many water distribution systems in this country are almost 100 years old. About 26 percent of piping in these systems is made of unlined cast iron or steel and is in poor condition. Many methods that locate leaks in these pipes are time-consuming, costly, disruptive to operations...

  11. Detection of JNI Memory Leaks Based on Extended Bytecode%基于中间语言的 JNI内存泄漏检查

    Institute of Scientific and Technical Information of China (English)

    蒋挺宇; 王鹏; 杨述; 褥震; 董渊; 王生原; 嵇智源

    2015-01-01

    JNI技术支持Java与本地C/C++的相互调用,在Android等混合语言实现的系统中有着广泛应用,但语言之间的安全特性差异使其成为安全薄弱环节,现有的分析方法难以处理多语言相互调用产生的安全缺陷。以JNI调用中易产生的内存泄漏为例,开展Java/C++JNI跨语言分析的研究。采用扩展的Java Bytecode(Bytecode倡)指令作为C++语义的解释来消除跨语言分析的障碍。围绕JNI调用中内存泄漏的问题,做了以下3方面工作:1)定义兼容Java/C++语言的分块内存模型;2)基于LLVM/LLJVM ,设计实现了C++到Bytecode倡的翻译策略;3)建立方法调用图,提取方法摘要,利用过程间分析方法检测JNI调用中的内存泄漏。针对具有典型内存泄漏特征的JNI实例翻译检测表明,该工作能够准确检测出Java/C++混合语言中的内存泄漏,对于JNI混合语言编程的理解和漏洞分析具有重要价值。%The Java native interface(JNI)enables Java code running in a Java virtual machine(JVM ) to be called by native code ,but the difference of security features between languages makes it a security weakness ,which cannot be detected by existing analysis methods .Commonly used detection methods are mainly based on the analysis of intermediate language ,w hich is invalid in this JNI case ,since the lack of an intermediate representation to bridge Java and C+ + .This paper analyzes JNI from a Java/C+ + cross‐language perspective and focuses on memory leaks which frequently occur in JNI calls .In order to overcome language barriers ,this paper proposes extended Bytecode (Bytecode* ) instructions as interpretation of C+ + semantics .Our contributions are described as follows :1)Define a block memory model which is compatible with both Java and C+ + ;2) Design translation rules from C+ +to extended Java Bytecode based on LLVM/LLJVM ;3)Construct a method call graph ,extract

  12. CO{sub 2} leak detection in motor car air conditioner components; CO{sub 2}-Lecksuche an Teilen fuer Automobilklimaanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Schopphoff, A. [Pfeiffer Vacuum, Asslar (Germany)

    2005-07-01

    A test chamber is presented which can detect leak rates of < 0,5 g/a in a CO{sub 2} air conditioner. Requirements are: 1. a low CO{sub 2} background, which is achieved by evacuation of a vacuum chamber; 2. a sensitive sensor (mass spectrometer) with equally high sensitivity for all gases. [German] Mit Hilfe der vorgestellten Testkammer lassen sich Leckraten von < 0,5 g/a in einer CO{sub 2}-Klimaanlage detektieren. Voraussetzung sind: 1. ein niedriger CO{sub 2} Untergrund, der in diesem Aufbau durch das Evakuieren einer Vakuumkammer erreicht wird, und 2. ein empfindlicher Sensor, der alle Gase mit gleicher hoher Genauigkeit messen kann (Massenspektrometer).

  13. Analysis of Underground Storage Tanks System Materials to Increased Leak Potential Associated with E15 Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Kass, Michael D [ORNL; Theiss, Timothy J [ORNL; Janke, Christopher James [ORNL; Pawel, Steven J [ORNL

    2012-07-01

    include model year 2001 light-duty vehicles, but specifically prohibited use in motorcycles and off-road vehicles and equipment. UST stakeholders generally consider fueling infrastructure materials designed for use with E0 to be adequate for use with E10, and there are no known instances of major leaks or failures directly attributable to ethanol use. It is conceivable that many compatibility issues, including accelerated corrosion, do arise and are corrected onsite and, therefore do not lead to a release. However, there is some concern that higher ethanol concentrations, such as E15 or E20, may be incompatible with current materials used in standard gasoline fueling hardware. In the summer of 2008, DOE recognized the need to assess the impact of intermediate blends of ethanol on the fueling infrastructure, specifically located at the fueling station. This includes the dispenser and hanging hardware, the underground storage tank, and associated piping. The DOE program has been co-led and funded by the Office of the Biomass Program and Vehicle Technologies Program with technical expertise from the Oak Ridge National Laboratory (ORNL) and the National Renewable Energy Laboratory (NREL). The infrastructure material compatibility work has been supported through strong collaborations and testing at Underwriters Laboratories (UL). ORNL performed a compatibility study investigating the compatibility of fuel infrastructure materials to gasoline containing intermediate levels of ethanol. These results can be found in the ORNL report entitled Intermediate Ethanol Blends Infrastructure Materials Compatibility Study: Elastomers, Metals and Sealants (hereafter referred to as the ORNL intermediate blends material compatibility study). These materials included elastomers, plastics, metals and sealants typically found in fuel dispenser infrastructure. The test fuels evaluated in the ORNL study were SAE standard test fuel formulations used to assess material-fuel compatibility within a

  14. Analysis of Underground Storage Tanks System Materials to Increased Leak Potential Associated with E15 Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Kass, Michael D [ORNL; Theiss, Timothy J [ORNL; Janke, Christopher James [ORNL; Pawel, Steven J [ORNL

    2012-07-01

    include model year 2001 light-duty vehicles, but specifically prohibited use in motorcycles and off-road vehicles and equipment. UST stakeholders generally consider fueling infrastructure materials designed for use with E0 to be adequate for use with E10, and there are no known instances of major leaks or failures directly attributable to ethanol use. It is conceivable that many compatibility issues, including accelerated corrosion, do arise and are corrected onsite and, therefore do not lead to a release. However, there is some concern that higher ethanol concentrations, such as E15 or E20, may be incompatible with current materials used in standard gasoline fueling hardware. In the summer of 2008, DOE recognized the need to assess the impact of intermediate blends of ethanol on the fueling infrastructure, specifically located at the fueling station. This includes the dispenser and hanging hardware, the underground storage tank, and associated piping. The DOE program has been co-led and funded by the Office of the Biomass Program and Vehicle Technologies Program with technical expertise from the Oak Ridge National Laboratory (ORNL) and the National Renewable Energy Laboratory (NREL). The infrastructure material compatibility work has been supported through strong collaborations and testing at Underwriters Laboratories (UL). ORNL performed a compatibility study investigating the compatibility of fuel infrastructure materials to gasoline containing intermediate levels of ethanol. These results can be found in the ORNL report entitled Intermediate Ethanol Blends Infrastructure Materials Compatibility Study: Elastomers, Metals and Sealants (hereafter referred to as the ORNL intermediate blends material compatibility study). These materials included elastomers, plastics, metals and sealants typically found in fuel dispenser infrastructure. The test fuels evaluated in the ORNL study were SAE standard test fuel formulations used to assess material-fuel compatibility within a

  15. Leak detection in pipelines based on inverse transient analysis and mixed integer nonlinear programming[Includes the CSCE forum on professional practice and career development : 1. international engineering mechanics and materials specialty conference : 1. international/3. coastal, estuarine and offshore engineering specialty conference : 2. international/8. construction specialty conference

    Energy Technology Data Exchange (ETDEWEB)

    Shamloo, H.; Haghighi, A. [K.N. Toosi Univ. of Technology, Tehran (Iran, Islamic Republic of). Dept. of Civil Engineering

    2009-07-01

    The flow properties of pipes are affected by leaks. Leak detection methods based on hydraulic modelling and real data records aim to find a pipe's leak parameters including their number, location and size. Inverse Transient Analysis (ITA), generally in time domain, is a powerful approach to develop leak detection methods with considerable benefits. This paper introduced an ITA based leak detection method along with a numerical model developed for direct transient analysis of leaks in pipes using method of characteristics (MOC). Transient state flow was generated in pipe and the pressure fluctuations were sampled only at the end valve location. To minimize the effects of unsteadiness and uncertainties due to the numerical modeling and also practical problems caused by water hammer, the downstream end valve was considered to be closed gradually within a long enough time. Then, using the sampled data and a direct transient analysis model, a mixed integer nonlinear program was developed. A mixed genetic algorithm was used in which the binary chromosomes were decoded as mixed integer leak locations and real leak areas. In order to find unknown leak parameters in a pipe, an objective function was defined using the least squares criterion of differences between observed and calculated pressure heads at the valve location. The genetic algorithm was found to be a powerful and easy to use optimization tool to solve complicated mixed integer nonlinear program (MINLP) problems in leak detection. 24 refs., 1 tab., 7 figs.

  16. Research project RoboGas{sup Inspector}. Gas leak detection with autonomous mobile robots; Forschungsprojekt RoboGas{sup Inspector}. Gaslecksuche mit autonomen mobilen Robotern

    Energy Technology Data Exchange (ETDEWEB)

    Habib, Abdelkarim [BAM Bundesanstalt fuer Materialforschung und -pruefung, Berlin (Germany); Bonow, Gero; Kroll, Andreas [Fachgebiet Mess- und Regelungstechnik, Universitaet Kassel, Kassel (Germany); Hegenberg, Jens; Schmidt, Ludger [Fachgebiet Mensch-Maschine-Systemtechnik, Universitaet Kassel, Kassel (Germany); Barz, Thomas; Schulz, Dirk [Fraunhofer FKIE, Unbemannte Systeme, Wachtberg (Germany)

    2013-05-15

    As part of the promotional program AUTONOMIK of the Federal Ministry of Economics and Technology (Berlin, Federal Republic of Germany) a consortium of nine project partners developed a prototype of an autonomous mobile robot looking for gas leaks in extended industrial equipment. The autonomous mobility of the system for any systems was implemented using different types of sensors for self-localization and navigation. The tele-operation enables a manual intervention in the process. The robot performs inspection tasks in industrial plants by means of video technology and remote gas measurement technology without driving into the possible risk areas and without the presence of humans. The robot can be used for routine inspections of facilities or for the targeted inspection of specific plant components. Thanks to the remote sensing technique also plant components can be inspected which are difficult to be inspected due to their limited accessibility by conventional measurement techniques.

  17. Semiconductor radiation detection systems

    CERN Document Server

    2010-01-01

    Covers research in semiconductor detector and integrated circuit design in the context of medical imaging using ionizing radiation. This book explores other applications of semiconductor radiation detection systems in security applications such as luggage scanning, dirty bomb detection and border control.

  18. Analytical and experimental studies of leak location and environment characterization for the international space station

    Energy Technology Data Exchange (ETDEWEB)

    Woronowicz, Michael; Blackmon, Rebecca; Brown, Martin [Stinger Ghaffarian Technologies, Inc, 7701 Greenbelt Rd, Greenbelt, MD 20770 (United States); Abel, Joshua; Hawk, Doug [Alliant Techsystems, Inc, 5050 Powder Mill Road, Beltsville, Maryland 20705 (United States); Autrey, David; Glenn, Jodie [Lockheed Martin, 1300 Hercules, Houston, TX 77058 (United States); Bond, Tim; Buffington, Jesse [NASA Johnson Space Flight Center, 2101 NASA Pkwy, Houston, TX 77058 (United States); Cheng, Edward; Ma, Jonathan; Rossetti, Dino [Conceptual Analytics, 8209 Woburn Abbey Rd, Glenn Dale, MD 20769 (United States); DeLatte, Danielle [ASRC Federal Space and Defense, 7000 Muirkirk Meadows Drive, Suite 100, Beltsville, MD 20705 (United States); Garcia, Kelvin; Mohammed, Jelila; Montt de Garcia, Kristina; Perry, Radford [NASA Goddard Space Flight Center, 8800 Greenbelt Rd, Greenbelt, MD 20771 (United States); Tull, Kimathi [Jackson and Tull, 7375 Executive Pl, Lanham, MD 20706 (United States); Warren, Eric [Wyle STE Group, 1290 Hercules Ave, Houston, TX 77058-2769 (United States)

    2014-12-09

    The International Space Station program is developing a robotically-operated leak locator tool to be used externally. The tool would consist of a Residual Gas Analyzer for partial pressure measurements and a full range pressure gauge for total pressure measurements. The primary application is to demonstrate the ability to detect NH{sub 3} coolant leaks in the ISS thermal control system. An analytical model of leak plume physics is presented that can account for effusive flow as well as plumes produced by sonic orifices and thruster operations. This model is used along with knowledge of typical RGA and full range gauge performance to analyze the expected instrument sensitivity to ISS leaks of various sizes and relative locations (“directionality”). The paper also presents experimental results of leak simulation testing in a large thermal vacuum chamber at NASA Goddard Space Flight Center. This test characterized instrument sensitivity as a function of leak rates ranging from 1 lb{sub m/}/yr. to about 1 lb{sub m}/day. This data may represent the first measurements collected by an RGA or ion gauge system monitoring off-axis point sources as a function of location and orientation. Test results are compared to the analytical model and used to propose strategies for on-orbit leak location and environment characterization using the proposed instrument while taking into account local ISS conditions and the effects of ram/wake flows and structural shadowing within low Earth orbit.

  19. Analytical and experimental studies of leak location and environment characterization for the international space station

    Science.gov (United States)

    Woronowicz, Michael; Abel, Joshua; Autrey, David; Blackmon, Rebecca; Bond, Tim; Brown, Martin; Buffington, Jesse; Cheng, Edward; DeLatte, Danielle; Garcia, Kelvin; Glenn, Jodie; Hawk, Doug; Ma, Jonathan; Mohammed, Jelila; de Garcia, Kristina Montt; Perry, Radford; Rossetti, Dino; Tull, Kimathi; Warren, Eric

    2014-12-01

    The International Space Station program is developing a robotically-operated leak locator tool to be used externally. The tool would consist of a Residual Gas Analyzer for partial pressure measurements and a full range pressure gauge for total pressure measurements. The primary application is to demonstrate the ability to detect NH3 coolant leaks in the ISS thermal control system. An analytical model of leak plume physics is presented that can account for effusive flow as well as plumes produced by sonic orifices and thruster operations. This model is used along with knowledge of typical RGA and full range gauge performance to analyze the expected instrument sensitivity to ISS leaks of various sizes and relative locations ("directionality"). The paper also presents experimental results of leak simulation testing in a large thermal vacuum chamber at NASA Goddard Space Flight Center. This test characterized instrument sensitivity as a function of leak rates ranging from 1 lbm//yr. to about 1 lbm/day. This data may represent the first measurements collected by an RGA or ion gauge system monitoring off-axis point sources as a function of location and orientation. Test results are compared to the analytical model and used to propose strategies for on-orbit leak location and environment characterization using the proposed instrument while taking into account local ISS conditions and the effects of ram/wake flows and structural shadowing within low Earth orbit.

  20. Analysis of Waste Leak and Toxic Chemical Release Accidents from Waste Feed Delivery (WFD) Diluent System

    Energy Technology Data Exchange (ETDEWEB)

    WILLIAMS, J.C.

    2000-09-15

    Radiological and toxicological consequences are calculated for 4 postulated accidents involving the Waste Feed Delivery (WFD) diluent addition systems. Consequences for the onsite and offsite receptor are calculated. This analysis contains technical information used to determine the accident consequences for the River Protection Project (RPP) Final Safety Analysis Report (FSAR).

  1. Research and application of natural gas leak emergency response system%天然气泄露应急处置系统研究与应用

    Institute of Scientific and Technical Information of China (English)

    崔国刚; 李磊; 薛忠林; 彭传潘

    2012-01-01

    Typical diffusion H2S-containing gas leak, for example, the use of dynamic numerical simulation techniques to study the natural gas leaked diffusion model HYSPLIT software based on pollutant dispersion analysis software, the environmental database, the design database , construction database, emergency resource database data and combined with three-dimensional simulation technology, three-dimensional GIS software SkyLine based support platform, construction of three-dimensional GIS emergency response system, developed through the system leaked near topography leaked diffusion sphere of influence, residents of evacuation routes, emergency broadcast point will need to start the emergency plan query, locate and display features, to get H2S leak proliferation of the affected area of the gathering and transportation of natural gas or drilling systems in complex terrain and under different weather conditions, natural gas leak commanding departments provide accurate, fast and efficient data and technical support, sustainable development in order to ensure the safety and health of the high-sulfur gas field development and production.%以含H2S天然气泄漏典型扩散为例,采用动态数值模拟技术,在污染物扩散分析软件HYSPLIT软件基础上研究天然气泄露扩散模型,利用环境数据库、设计数据库、施工数据库、应急资源数据库等数据并结合三维模拟技术,以三维GIS软件SkyLine为基础支撑平台,建设三维GIS应急处置系统,通过系统开发实现泄露点附近的地形地貌、泄露扩散影响范围、居民疏散路线、需启动的应急广播点、应急预案等查询、定位及展示功能,以得到复杂地形及不同气象条件下天然气集输或钻采系统H2S泄漏扩散所影响的区域,在天然气泄漏后为指挥部门提供准确、快速、高效的数据及技术支持,以保证高含硫气田开发生产的安全和健康可持续发展.

  2. SINGLE-SHELL TANKS LEAK INTEGRITY ELEMENTS/SX FARM LEAK CAUSES AND LOCATIONS - 12127

    Energy Technology Data Exchange (ETDEWEB)

    VENETZ TJ; WASHENFELDER D; JOHNSON J; GIRARDOT C

    2012-01-25

    Washington River Protection Solutions, LLC (WRPS) developed an enhanced single-shell tank (SST) integrity project in 2009. An expert panel on SST integrity was created to provide recommendations supporting the development of the project. One primary recommendation was to expand the leak assessment reports (substitute report or LD-1) to include leak causes and locations. The recommendation has been included in the M-045-9IF Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) as one of four targets relating to SST leak integrity. The 241-SX Farm (SX Farm) tanks with leak losses were addressed on an individual tank basis as part of LD-1. Currently, 8 out of 23 SSTs that have been reported to having a liner leak are located in SX Farm. This percentage was the highest compared to other tank farms which is why SX Farm was analyzed first. The SX Farm is comprised of fifteen SSTs built 1953-1954. The tanks are arranged in rows of three tanks each, forming a cascade. Each of the SX Farm tanks has a nominal I-million-gal storage capacity. Of the fifteen tanks in SX Farm, an assessment reported leak losses for the following tanks: 241-SX-107, 241-SX-108, 241-SX-109, 241-SX-111, 241-SX-112, 241-SX-113, 241-SX-114 and 241-SX-115. The method used to identify leak location consisted of reviewing in-tank and ex-tank leak detection information. This provided the basic data identifying where and when the first leaks were detected. In-tank leak detection consisted of liquid level measurement that can be augmented with photographs which can provide an indication of the vertical leak location on the sidewall. Ex-tank leak detection for the leaking tanks consisted of soil radiation data from laterals and drywells near the tank. The in-tank and ex-tank leak detection can provide an indication of the possible leak location radially around and under the tank. Potential leak causes were determined using in-tank and ex-tank information that is not directly related to

  3. Analyzing User Awareness of Privacy Data Leak in Mobile Applications

    Directory of Open Access Journals (Sweden)

    Youngho Kim

    2015-01-01

    Full Text Available To overcome the resource and computing power limitation of mobile devices in Internet of Things (IoT era, a cloud computing provides an effective platform without human intervention to build a resource-oriented security solution. However, existing malware detection methods are constrained by a vague situation of information leaks. The main goal of this paper is to measure a degree of hiding intention for the mobile application (app to keep its leaking activity invisible to the user. For real-world application test, we target Android applications, which unleash user privacy data. With the TaintDroid-ported emulator, we make experiments about the timing distance between user events and privacy leaks. Our experiments with Android apps downloaded from the Google Play show that most of leak cases are driven by user explicit events or implicit user involvement which make the user aware of the leakage. Those findings can assist a malware detection system in reducing the rate of false positive by considering malicious intentions. From the experiment, we understand better about app’s internal operations as well. As a case study, we also presents a cloud-based dynamic analysis framework to perform a traffic monitor.

  4. Investigation on the sodium leak accident of Monju. Sodium leak test simulating the Monju leak

    Energy Technology Data Exchange (ETDEWEB)

    Shimoyama, Kazuhito; Nishimura, Masahiro; Miyahara, Shinya; Miyake, Osamu; Tanabe, Hiromi [Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan). Oarai Engineering Center; Usami, Masayuki

    1996-11-01

    Sodium fire experiments were carried out two times using the Sodium Fire Test Rig (SOFT-1) in the Power Reactor and Nuclear Fuel Development Corp (PNC) as a part of works to research the cause of the accident in secondary main cooling system of Monju. The purposes of these experiments are to confirm the leak rate and leakage form of sodium from damaged thermometer, to confirm the damage to the piping insulating structure around the thermometer and to the flexible tube, and to compare the temperature history of the signal from the thermometer between the experiments and Monju. In the experiments 56({+-}2)g/sec was obtained as the leak rate under the condition of ensuring the leakage pass in the simulated thermometer. This leak rate was corrected to 53g/sec to take account of manufacturing error of the thermometer between the experiment and Monju. In calculation of this leak rate, it is assumed that the annulus size of thermometer well tip is a nominal distance and pressure value to the leakage sodium is 1.65kg/cm{sup 2}G, which was the maximum one during the leakage of Monju. The behavior of signal from the simulated thermometer was very similar to that of the damaged thermometer in Monju and it was confirmed this temperature history could be sufficiently explained by moving of the temperature contact position of the thermocouple following the runoff of leakage sodium. (J.P.N.)

  5. Evaluation of methodologies for the calculation of leak rates for pressure retaining components with crack-like leaks; Bewertung von Methoden zur Berechnung von Leckraten fuer druckfuehrende Komponenten mit rissartigen Lecks

    Energy Technology Data Exchange (ETDEWEB)

    Sievers, Juergen; Heckmann, Klaus; Blaesius, Christoph

    2015-06-15

    For the demonstration of break preclusion for pressure retaining components in nuclear power plants, the nuclear safety standard KTA 3206 determines also the requirements for the leak-before-break verification. For this procedure, it has to be ensured that a wall-penetrating crack is subcritical with respect to instable growth, and that the resulting leakage under stationary operation conditions can be detected by a leak detection system. Within the scope of the project 3613R01332 analyses with respect to conservative estimates of the leak rates in case of detections regarding break preclusion were performed by means of leak rate models being available at GRS. For this purpose, conservative assumptions in the procedure were quantified by comparative calculations concerning selected leak rate experiments and the requirements regarding the determination of leak rates indicated in the KTA 3206 were verified and specified. Moreover, the models were extended and relevant recommendations for the calculation procedure were developed. During the investigations of leak rate tests the calculation methods were validated, qualified by means of both examples indicated in KTA 3206 and applied to a postulated leak accident in the cooling circuit of a PWR. For the calculation of leak rates several simplified solution methods which are included in the GRS program WinLeck were applied, and for the simulation of a leak accident the large-scale programs ANSYS Mechanical and ATHLET (thermohydraulics program developed by GRS) were used. When applying simplified methods for the calculation of leak rates using the limiting curve for the friction factor which has been derived during the project and which is included in the KTA 3206 attention has to be paid to the fact that in case of small flow lengths the entrance loss can dominate compared to the friction loss. However, the available data do not suffice in order to make a quantitative statement with respect to limits of applicability

  6. Quality Assurance Project Plan: Suitability of Leak Detection Technology for Use In Ethanol-Blended Fuel Service

    Science.gov (United States)

    Oversight of this investigation will be provided by the U.S. Environmental Protection Agency through the Environmental Technology Verification (ETV) Program. This project will be performed by Battelle, which manages the ETV Advanced Monitoring Systems (AMS) Center through a coop...

  7. Quality Assurance Project Plan: Suitability of Leak Detection Technology for Use In Ethanol-Blended Fuel Service

    Science.gov (United States)

    Oversight of this investigation will be provided by the U.S. Environmental Protection Agency through the Environmental Technology Verification (ETV) Program. This project will be performed by Battelle, which manages the ETV Advanced Monitoring Systems (AMS) Center through a coop...

  8. Leak detection method for in-orbit spacecraft using circular ultrasonic sensor array%基于圆形超声阵列传感器的在轨泄漏定位方法

    Institute of Scientific and Technical Information of China (English)

    孟冬辉; 闫荣鑫; 郭欣

    2011-01-01

    In view of more and more debris in space, it is an important issue to locate the leak point in manned spacecraft cabin. In this paper, a leak detection method is developed for spacecraft on orbit using circular ultrasonic array sensors. The time difference of the ultrasonic signal reaching different ultrasonic units is calculated by cross correlation, and then the direction of the leak is determined. The leak location can then be identified by triangulation with three ultrasonic array sensors.%随着空间碎片数量的不断增加,载人航天器在轨泄漏定位问题成为一个亟待解决的问题.文章研究了一种基于圆形超声阵列传感器的在轨泄漏定位方法,利用互相关原理计算泄漏超声信号传播到不同测试单元的时间差,从而确定泄漏所在的方向,并根据三角定位方法确定漏孔的具体位置.

  9. Gas Flow Detection System

    Science.gov (United States)

    Moss, Thomas; Ihlefeld, Curtis; Slack, Barry

    2010-01-01

    This system provides a portable means to detect gas flow through a thin-walled tube without breaking into the tubing system. The flow detection system was specifically designed to detect flow through two parallel branches of a manifold with only one inlet and outlet, and is a means for verifying a space shuttle program requirement that saves time and reduces the risk of flight hardware damage compared to the current means of requirement verification. The prototype Purge Vent and Drain Window Cavity Conditioning System (PVD WCCS) Flow Detection System consists of a heater and a temperature-sensing thermistor attached to a piece of Velcro to be attached to each branch of a WCCS manifold for the duration of the requirement verification test. The heaters and thermistors are connected to a shielded cable and then to an electronics enclosure, which contains the power supplies, relays, and circuit board to provide power, signal conditioning, and control. The electronics enclosure is then connected to a commercial data acquisition box to provide analog to digital conversion as well as digital control. This data acquisition box is then connected to a commercial laptop running a custom application created using National Instruments LabVIEW. The operation of the PVD WCCS Flow Detection System consists of first attaching a heater/thermistor assembly to each of the two branches of one manifold while there is no flow through the manifold. Next, the software application running on the laptop is used to turn on the heaters and to monitor the manifold branch temperatures. When the system has reached thermal equilibrium, the software application s graphical user interface (GUI) will indicate that the branch temperatures are stable. The operator can then physically open the flow control valve to initiate the test flow of gaseous nitrogen (GN2) through the manifold. Next, the software user interface will be monitored for stable temperature indications when the system is again at

  10. Developing an early laekage detection system for thermal power plant boiler tubes by using acoustic emission technology

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Bum [RECTUSON, Co., LTD, Masan (Korea, Republic of); Roh, Seon Man [Samcheonpo Division, Korea South-East Power Co., Samcheonpo (Korea, Republic of)

    2016-06-15

    A thermal power plant has a heat exchanger tube to collect and convert the heat generated from the high temperature and pressure steam to energy, but the tubes are arranged in a complex manner. In the event that a leakage occurs in any of these tubes, the high-pressure steam leaks out and may cause the neighboring tubes to rupture. This leakage can finally stop power generation, and hence there is a dire need to establish a suitable technology capable of detecting tube leaks at an early stage even before it occurs. As shown in this paper, by applying acoustic emission (AE) technology in existing boiler tube leak detection equipment (BTLD), we developed a system that detects these leakages early enough and generates an alarm at an early stage to necessitate action; the developed system works better that the existing system used to detect fine leakages. We verified the usability of the system in a 560 MW-class thermal power plant boiler by conducting leak tests by simulating leakages from a variety of hole sizes (⌀2, ⌀5, ⌀10 mm). Results show that while the existing fine leakage detection system does not detect fine leakages of ⌀2 mm and ⌀5 mm, the newly developed system could detect leakages early enough and generate an alarm at an early stage, and it is possible to increase the signal to more than 18 dB.

  11. Immunity Based Worm Detection System

    Institute of Scientific and Technical Information of China (English)

    HONG Zheng; WU Li-fa; WANG Yuan-yuan

    2007-01-01

    Current worm detection methods are unable to detect multi-vector polymorphic worms effectively.Based on negative selection mechanism of the immune system,a local network worm detection system that detects worms was proposed.Normal network service requests were represented by self-strings,and the detection system used self-strings to monitor the network for anomaly.According to the properties of worm propagation,a control center correlated the anomalies detected in the form of binary trees to ensure the accuracy of worm detection.Experiments show the system to be effective in detecting the traditional as well as multi-vector polymorphic worms.

  12. 移动应用程序内存泄露机制分析与检测方案设计%Application code memory leak analysis and detecting technology research in mobile

    Institute of Scientific and Technical Information of China (English)

    朱洪军; 韩洋; 华保健; 陈灏

    2016-01-01

    Android development has become a hot field of mobile development, but memory usage problems in Android applications are often overlooked, part of the developers are lack of knowledge of Java garbage collection mechanism, which makes the memory leak become a very important issues in security area of Android application development. In this paper, the harm of memory leaks is expounded, it introduces some scenario of memory leak and sorts them according to the correlation of four components of Android, finally summarizes characteristics and puts forward a kind of memory leak code static code memory leak detection scheme based on symbolic execution.%Android开发已经成为移动开发热门领域,Android应用程序中内存使用的问题却经常容易被忽视,部分开发者对Java垃圾回收机制认识模糊,使得内存泄漏成为Android应用开发中十分隐秘但又确实存在的应用安全问题,对内存泄漏的危害进行了阐述,并根据与Activity、Service、ContentProvider、Broadcast Receiver等Android组件的相关性归类介绍了一些常见的典型内存泄漏情景,最后分析总结内存泄漏代码特征,并设计一种基于符号执行的内存泄漏静态代码检测方案。

  13. A Systemic Capillary Leak Syndrome (Clarkson Syndrome) in a Patient with Chronic Lymphocytic Leukemia: A Case Report in an Out-of-Hospital Setting

    Science.gov (United States)

    Durand Bechu, Manon; Rouget, Antoine; Recher, Christian; Azoulay, Elie; Bounes, Vincent

    2016-01-01

    Systemic Capillary Leak Syndrome (SCLS) is a rare disease with poor prognosis, characterized by the occurrence of mucocutaneous and visceral edema with hypotension, hemoconcentration, and unexpected hypoalbuminemia. The disease can be idiopathic (Clarkson syndrome) or secondary to other diseases and treatments. We describe this syndrome in a prehospitalized, 63-year-old patient with chronic lymphocytic leukemia and an idiopathic form of SCLS manifesting as hypovolemic shock. Initial care is hospitalization in intensive care. In addition to etiological treatment if fluid replacement is necessary, treatment must be closely monitored for secondary overload complications. Catecholamine rather than arrhythmogenic support may be associated. PMID:27069700

  14. A Systemic Capillary Leak Syndrome (Clarkson Syndrome in a Patient with Chronic Lymphocytic Leukemia: A Case Report in an Out-of-Hospital Setting

    Directory of Open Access Journals (Sweden)

    Manon Durand Bechu

    2016-01-01

    Full Text Available Systemic Capillary Leak Syndrome (SCLS is a rare disease with poor prognosis, characterized by the occurrence of mucocutaneous and visceral edema with hypotension, hemoconcentration, and unexpected hypoalbuminemia. The disease can be idiopathic (Clarkson syndrome or secondary to other diseases and treatments. We describe this syndrome in a prehospitalized, 63-year-old patient with chronic lymphocytic leukemia and an idiopathic form of SCLS manifesting as hypovolemic shock. Initial care is hospitalization in intensive care. In addition to etiological treatment if fluid replacement is necessary, treatment must be closely monitored for secondary overload complications. Catecholamine rather than arrhythmogenic support may be associated.

  15. Scanning, standoff TDLAS leak imaging and quantification

    Science.gov (United States)

    Wainner, Richard T.; Aubut, Nicholas F.; Laderer, Matthew C.; Frish, Michael B.

    2017-05-01

    This paper reports a novel quantitative gas plume imaging tool, based on active near-infrared Backscatter Tunable Diode Laser Absorption Spectroscopy (b-TDLAS) technology, designed for upstream natural gas leak applications. The new tool integrates low-cost laser sensors with video cameras to create a highly sensitive gas plume imager that also quantifies emission rate, all in a lightweight handheld ergonomic package. It is intended to serve as a lower-cost, higherperformance, enhanced functionality replacement for traditional passive non-quantitative mid-infrared Optical Gas Imagers (OGI) which are utilized by industry to comply with natural gas infrastructure Leak Detection and Repair (LDAR) requirements. It addresses the need for reliable, robust, low-cost sensors to detect and image methane leaks, and to quantify leak emission rates, focusing on inspections of upstream oil and gas operations, such as well pads, compressors, and gas plants. It provides: 1) Colorized quantified images of path-integrated methane concentration. The images depict methane plumes (otherwise invisible to the eye) actively interrogated by the laser beam overlaid on a visible camera image of the background. The detection sensitivity exceeds passive OGI, thus simplifying the manual task of leak detection and location; and 2) Data and algorithms for using the quantitative information gathered by the active detection technique to deduce plume flux (i.e. methane emission rate). This key capability will enable operators to prioritize leak repairs and thereby minimize the value of lost product, as well as to quantify and minimize greenhouse gas emissions, using a tool that meets EPA LDAR imaging equipment requirements.

  16. 77 FR 6857 - Pipeline Safety: Notice of Public Meetings on Improving Pipeline Leak Detection System...

    Science.gov (United States)

    2012-02-09

    ... and Research 5:45 p.m. Wrap-Up/Next Steps 6 p.m. Adjournment Preliminary Agenda for the Public Meeting... Pipelines 12:30 p.m. Lunch 2 p.m. Panel 3: Valve Capabilities, Limitations and Research 4 p.m. Wrap-Up/Next... Administrator for Pipeline Safety. BILLING CODE 4910-60-P...

  17. Investigation of Low Cost Sensor-Based Leak Detection System for Fence Line Applications

    Science.gov (United States)

    With recent technological advances, low-cost time-resolved sensors may become effective tools to support time-integrated passive sampling strategies by helping to decipher origin of emissions in real-time. As part of the Petroleum Refinery Risk and Technology Review, New Source ...

  18. Investigation of a Low Cost Sensor-Based Leak Detection System for Fence Line Applications

    Science.gov (United States)

    With recent technological advances, low-cost time-resolved sensors may become effective tools to support time-integrated passive sampling strategies by helping to decipher origin of emissions in real-time. As part of the Petroleum Refinery Risk and Technology Review, New Source P...

  19. Margins in high temperature leak-before-break assessments

    Energy Technology Data Exchange (ETDEWEB)

    Budden, P.J.; Hooton, D.G.

    1997-04-01

    Developments in the defect assessment procedure R6 to include high-temperature mechanisms in Leak-before-Break arguments are described. In particular, the effect of creep on the time available to detect a leak and on the crack opening area, and hence leak rate, is discussed. The competing influence of these two effects is emphasized by an example. The application to Leak-before-Break of the time-dependent failure assessment diagram approach for high temperature defect assessment is then outlined. The approach is shown to be of use in assessing the erosion of margins by creep.

  20. In-Space Distributed Fiber Optic Hydrogen Leak Sensor Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Broadband Photonics Inc. proposes development of a patent-pending distributed fiber optic sensor for in-space hydrogen leak detection. Reliable and fast detection of...

  1. In-Space Distributed Fiber Optic Hydrogen Leak Sensor Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Broadband Photonics Inc. proposes development of a patent-pending distributed fiber optic sensor for in-space hydrogen leak detection. Reliable and fast detection of...

  2. Introduction to detection systems

    DEFF Research Database (Denmark)

    Larsen, Jan

    Presentation of the information processing pipleline for detection including discussing of various issues and the use of mathematical modeling. A simple example of detection a signal in noise illustrated that simple modeling outperforms human visual and auditory perception. Particiants are going...... to discuss issues in detection which is followed by an auditory object recognition exercise. The results of the exercise and its relation to issues in the information processing pipleline is also discussed....

  3. Remote leak localization approach for fusion machines

    Energy Technology Data Exchange (ETDEWEB)

    Durocher, Au., E-mail: aurelien.durocher@cea.fr [CEA-IRFM, F-13108 Saint Paul-Lez-Durance (France); Bruno, V.; Chantant, M.; Gargiulo, L. [CEA-IRFM, F-13108 Saint Paul-Lez-Durance (France); Gherman, T. [Floralis UJF Filiale, F-38610 Gières (France); Hatchressian, J.-C.; Houry, M.; Le, R.; Mouyon, D. [CEA-IRFM, F-13108 Saint Paul-Lez-Durance (France)

    2013-10-15

    120 °C), “ppm” traces of helium or water have been measured. To improve these first promising results, a new test-bed called ROVE (remote operation vacuum equipment) has been set up in 2012 to qualify leak sensors and remote operation. A list of concepts has been set out from contacts with manufacturers and laboratories. For sniffing solutions it includes laser absorption measurement, mass spectrometer analyses and vibrating quartz. For embeddable concepts thermal conductivity and capacitive sensors are considered. Choice of concepts to detect water or helium traces is based on major criteria, such as weight, high sensibility and fast response time and recovery time. They also have to be operational under primary vacuum conditions or atmospheric pressure and from ambient temperature to 60 °C.

  4. Active acoustic leak detection for LMFBR steam generators. Pt. 4. Experimental results for detection of bubble using the SG full sector model

    Energy Technology Data Exchange (ETDEWEB)

    Kumagai, Hiromichi [Central Research Inst. of Electric Power Industry, Komae, Tokyo (Japan). Komae Research Lab.

    1996-06-01

    In order to prevent the expansion of tube damages and to maintain structural safety in steam generators (SG) of fast breeder reactor (FBR), it is necessary to detect precisely and immediately the leakage of water from tubes of heat exchangers. The active acoustic method, which detects the sound attenuation due to bubbles generated at the sodium-water reactions, is being developed. In this paper, the attenuation characteristics of sound attenuated by bubbles are investigated experimentally by using the SG full sector model simulating the actual SG. An emitter and a receiver sensor are attached to the SG shell, and the attenuation of sounds due to passing of bubbles through the sound field is detected and measured. As a experimental result, it is clarified that the received sound attenuates immediately upon injection of bubbles, and the attenuation of sound are 2-5 dB at after 10 seconds from bubble injection of 10 l/s. The attenuation of sound are least affected by bubble injection location. (author)

  5. Leaks in gas mains - Location using GIS and GPS; Leckstellen in Gasrohrnetzen. Aufspueren mit Unterstuetzung durch GIS und GPS

    Energy Technology Data Exchange (ETDEWEB)

    Huber, D.

    2009-07-01

    This article takes a look how leaks in gas mains can be located with the help of geographical information systems (GIS) and the satellite-based Global Positioning System (GPS). The advantages for long-term planning and, in future, maintenance work are stressed. Experienced gained by the IWB utility in Basel, Switzerland, is discussed. Here, a system for the monitoring and maintenance of the whole of the City of Basel's natural gas supply network is discussed. Cost savings and a particularly improved increase in the quality of leak detection work is noted. Modern technology using GPS-based equipment in the detection of leaks in the gas mains is reviewed. An example of the documentation of the gas mains in a GIS system is given.

  6. Escape dynamics through a continuously growing leak

    Science.gov (United States)

    Kovács, Tamás; Vanyó, József

    2017-06-01

    We formulate a model that describes the escape dynamics in a leaky chaotic system in which the size of the leak depends on the number of the in-falling particles. The basic motivation of this work is the astrophysical process, which describes the planetary accretion. In order to study the dynamics generally, the standard map is investigated in two cases when the dynamics is fully hyperbolic and in the presence of Kolmogorov-Arnold-Moser islands. In addition to the numerical calculations, an analytic solution to the temporal behavior of the model is also derived. We show that in the early phase of the leak expansion, as long as there are enough particles in the system, the number of survivors deviates from the well-known exponential decay. Furthermore, the analytic solution returns the classical result in the limiting case when the number of particles does not affect the leak size.

  7. 基于时延的高精度泄漏点超声定向检测方法%High accuracy method of ultrasonic gas leak direction detection based on time delay estimation

    Institute of Scientific and Technical Information of China (English)

    廖平平; 蔡茂林

    2013-01-01

    In order to solve the low accuracy problem in current gas leak detection, a new ultrasonic leak detection method based on time delay estimation (TDE) was proposed. Three ultrasonic sensors arranged in an equilateral triangle and received the ultrasound generated by a gas leak and the leak direction can be determined according to time delays between the outputs of every two sensors. A TDE algorithm based on cubic spline interpolation was adopted to overcome the accuracy limit caused by sampling interval. For each kernel window length, delay estimates of 100 sets of experimental data were obtained and their mean squared errors (MSE) were calculated. Comparison between MSE of experimental data and Cramer-Rao lower bound showed that their changing tendency was accordant. Influences of MSE, the space between sensors and the distance between leak and sensor on direction accuracy were analyzed. Results show that the direction error increases with MSE, decreases with the space between sensors, and increases with distance between leak and sensor. The direction detection accuracy is improved by 7 ~10 times compared with detection method with single ultrasonic sensor.%针对当前气体泄漏点检测定向精度低的情况,提出一种基于时延的高精度超声检测方法.该方法利用3个呈等边三角形分布的超声传感器接收由泄漏点产生的超声波,根据3路信号的相对时延值确定泄漏点的方向.为克服采样间隔对时延估计精度的限制,采用基于三次样条插值的时延估计算法估计信号时延值,并对不同核窗长度下的各100组实验数据的时延值进行误差统计,得到其均方差并与其Cramér-Rao下界比较,发现二者的变化趋势具有良好的一致性.在此基础上研究了时延值均方差,超声传感器间距和泄漏点距离对定向精度的影响.结果表明:定向误差随时延值均方差增大而增大,随超声传感器间距增大而减小,随泄漏点距离增大而增大

  8. 105 K-West isolation barrier leak recovery plan

    Energy Technology Data Exchange (ETDEWEB)

    Wiborg, J.C.

    1995-03-02

    Leak testing is being performed in 105 KW to verify the performance of the isolation barriers which have been recently installed. When an 11 inch differential head is established between the main basin and the discharge chute, a leak-rate of approximately 30 - 35 gpm is observed. The leak-rate would be achieved by a 1.65`` - 2`` diameter hole (or equivalent). Analyses suggest that the flow is turbulent/laminar transitional (dominantly turbulent), which would be indicative of a single point leak, typical of a pipe or large opening. However, local vortex rotation is observed in the entry to the West transfer chute while no observable motion was seen in the East transfer chute: this may be an indication of seal leakage in the East isolation barrier. The potential for leakage had been considered during the design and field work planning stages. Review of potential leak detection technologies had been made; at the planning stage it was determined that location specific leak detection could be established relatively quickly, applying existing K Basins technology (dye or ultrasonics). The decision was made not to pre-stage leak detection since the equipment development is highly dependent on the nature and location of the leak, and the characteristics of the leak rate provides data which guides leak characterization technology. The expense could be deferred and potentially avoided without risk to critical path activity. Consistent with the above, a systematic recovery plan has been developed utilizing phased activities to provide for management discipline combined with timely diagnosis and correction. Because this activity is not critical path at this time, activities will be coordinated with other plant activity to optimize overall plant work. Particular care will be exercised in assuring that information gained from this recovery can be utilized in the more critical work in 105 KE.

  9. Development of the Human-machine Monitoring System with Configuration Software for Leak Detectors%气密性检测设备组态软件的人机监控系统开发

    Institute of Scientific and Technical Information of China (English)

    潘赛虎; 段锁林; 高玉梅

    2011-01-01

    In order to implement human-machine interaction for leak detection devices, the novel human-machine monitoring system based on panel PC has been designed. Through the communication between the configuration software and PLC, the system realizes the data exchange, monitor the detection site in real-time, control automatic and semi-automatic operation of the detection device; meanwhile, record and save the parameters and detection results of the valves. The monitoring system using configuration software features superior performance of commercial PC, and also offers ease operation function from touch screen. The implementation of the system provides consultable method for designing similar products.%为实现与气密性检测设备的人机交互,设计了基于平板电脑的新型人机监控系统.该系统通过组态软件与PLC的通信,实现两者数据的交换,实时监控气密性检测现场,并控制气密性检测设备的自动和半自动操作,同时完成对阀门的参数、检测结果的记录和保存.组态监控系统不仅具有普通商用计算机的优良性能,还具有触摸屏操作简单方便的特点.该系统的实现为同类产品的设计提供了可借鉴的方法.

  10. Summary of QRL 7-8 Repair and Re-installation Leak Test Results

    CERN Document Server

    Kos, N; CERN. Geneva. TE Department

    2009-01-01

    This note describes the leak tests that have been performed during the repair and re-installation of QRL sector 7-8 during 2005 and 2006. The leak tests were performed in UX65, where the pipe elements were refurbished before re-installation, and in the tunnel. A variety of leaks have been detected, localised and repaired in the tunnel, including weld defects, accidentally drilled holes and imported leaks in previously tested components.

  11. MASS SPECTROMETER LEAK

    Science.gov (United States)

    Shields, W.R.

    1960-10-18

    An improved valve is described for precisely regulating the flow of a sample fluid to be analyzed, such as in a mass spectrometer, where a gas sample is allowed to "leak" into an evacuated region at a very low, controlled rate. The flow regulating valve controls minute flow of gases by allowing the gas to diffuse between two mating surfaces. The structure of the valve is such as to prevent the corrosive feed gas from contacting the bellows which is employed in the operation of the valve, thus preventing deterioration of the bellows.

  12. 半导体真空腔体静态密封和检漏的研究%Static Sealing and Leak Detection of Semiconductor Vacuum Chamber

    Institute of Scientific and Technical Information of China (English)

    陈妙娟

    2016-01-01

    针对半导体真空腔体静态密封中存在的泄漏及高温时密封圈受损等密封性问题,重新对密封圈的选择和密封槽的设计计算进行了完善,并对完善后的真空腔体的密封性进行了一系列的检漏测试及探讨,从而证明了改善方案的可行性。%This article focused on solving the problems of static sealing which caused the air leak and the O-ring damaging at high temperature in semiconductor vacuum chamber by choosing the O-ring and improving the sealing groove .Through further studying and a series of air leak test of the improved vacuum chamber ,it is proved that the improved solution is feasible .

  13. Development Actualities of Pipeline Leak-detection Technologies at Home and Abroad%国内外油气管道泄漏检测技术的发展现状

    Institute of Scientific and Technical Information of China (English)

    夏海波; 张来斌; 王朝辉

    2001-01-01

    介绍了国内外用于油气管道泄漏的十几种检测方法,包括气体检测法、压力分布法、负压波检测法、质量平衡法、检测元件法、声波法、分段试压法、压力点分析法、压力波阵面检测法以及示踪剂检测法等。分析了各种管道泄漏检测技术的原理和各方法的优缺点。认为在现代计算机技术的支持下,那些基于快速算法的实时管道泄漏检测技术将显示其优越性。%In this paper,some oil and gas pipeline leak-detectiontechnologies at home and abroad are introduced,including gas detection method,pressure distribution method,negative pressure wave detection method,testing element method,acoustic wave method,parts testing pressure method,pressure point analysis,pressure wave front detection,tracer detection methods,radioactivity detection and pipeline instantaneous model method.The advantages and weaknesses of all detection methods are analyzed.The authors considers that in the support of modern computer technology,those real-time pipeline leak detection technologies on the basis of fast algorithm will demonstrate their advantages.

  14. Uncertainty evaluation of vacuum chamber leak detection method for spacecraft component%航天器单机产品真空室检漏法测量结果的不确定度评定

    Institute of Scientific and Technical Information of China (English)

    汪力; 王勇; 孙立臣; 孙立志; 张海峰; 史纪军; 郭海涛

    2012-01-01

    航天器推进系统的单机产品的漏率测试往往采用氦质谱真空室检漏法,研究该方法测量结果的不确定度评定具有重要的工程应用价值.本文首先对真空室检漏法的原理进行了分析探讨,并从不确定的基础理论出发系统地研究了氦质谱真空室检漏法测量结果的不确定度评定方法,并结合工作的具体案例给出了评价的具体步骤.%Vacuum chamber leak detection method is widely used in (he spacecraft components of propellent subsystem. So it is very important to study the uncertainty evaluation of this method. First, the principle of the vacuum chamber leak detection method was analyzed. Second, the method of uncertainty evaluation was studied based on the basic theory about uncertainty. Last, the detailed evaluation steps were given through a case.

  15. Remote Voice Detection System

    Science.gov (United States)

    2007-06-25

    back to the laser Doppler vibrometer and the digital camera, respectively. Mechanical beam steering mirror modules, such as galvanometer steering...mirror module 43 in accordance with this invention. An appropriate galvanometer -based tracker system has been used for tracking eye motion during laser

  16. A report on the leak before break design and evaluation of LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Bum; Lee, H. Y.; Joo, Y. S.; Lee, J. H. [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2002-05-01

    In this study, the necessity of leak before break application for Liquid Metal Reactors (LMR) was investigated and the outline of leak before break evaluation procedure for KALIMER reactor structures and components was proposed. In the 1st phase of this project, the theoretical background for leak before break procedure was prepared based upon the state-of-the-art technology of the advanced countries. In the 2nd phase of project, evaluation method of creep crack growth was studied and the leak before break evaluation procedure of French RCC-MRA -16 was analyzed. Also, creep-fatigue crack growth was assessed according to the Japanese JNC method and this will help to establish the KALIMER leak before break procedure. It is necessary to specify proposed KALIMER leak before break evaluation technique including high temperature crack growth evaluation, stability analysis of crack growth, leak rate evaluation method, and leak detection technology. 24 refs., 12 figs., 4 tabs. (Author)

  17. Design and Analysis of Control System for High Pressure Leak Tester Based on PLC%基于 PLC的高压测漏机控制系统设计与分析

    Institute of Scientific and Technical Information of China (English)

    王晓磊; 李晓丹

    2013-01-01

    To judge whether the inflatable shock absorber cylinder was qualified,a high pressure leak tester was developed. The working principle of the machine was introduced. Pneumatic control system and PLC control system structure were focused on. PLC main program function block diagram was given. Experiments show that the system is of reliable operation,simple control and so on, so the detection process automation is realized.%  为判断充气式减振器缸筒是否存在质量缺陷,开发一台高压测漏机。介绍该测漏机的工作原理,着重论述了气动控制系统和PLC控制系统的构成,给出了PLC主要程序的功能框图。实践证明:该系统具有运行可靠、控制简单等特点,实现了检测过程自动化。

  18. Centrifugal unbalance detection system

    Science.gov (United States)

    Cordaro, Joseph V.; Reeves, George; Mets, Michael

    2002-01-01

    A system consisting of an accelerometer sensor attached to a centrifuge enclosure for sensing vibrations and outputting a signal in the form of a sine wave with an amplitude and frequency that is passed through a pre-amp to convert it to a voltage signal, a low pass filter for removing extraneous noise, an A/D converter and a processor and algorithm for operating on the signal, whereby the algorithm interprets the amplitude and frequency associated with the signal and once an amplitude threshold has been exceeded the algorithm begins to count cycles during a predetermined time period and if a given number of complete cycles exceeds the frequency threshold during the predetermined time period, the system shuts down the centrifuge.

  19. Fault Detection for Nonlinear Systems

    DEFF Research Database (Denmark)

    Stoustrup, Jakob; Niemann, H.H.

    1998-01-01

    The paper describes a general method for designing fault detection and isolation (FDI) systems for nonlinear processes. For a rich class of nonlinear systems, a nonlinear FDI system can be designed using convex optimization procedures. The proposed method is a natural extension of methods based...

  20. 40 CFR 63.1005 - Leak repair.

    Science.gov (United States)

    2010-07-01

    ... successful repair of the leak. (3) Maximum instrument reading measured by Method 21 of 40 CFR part 60... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Leak repair. 63.1005 Section 63.1005... Standards for Equipment Leaks-Control Level 1 § 63.1005 Leak repair. (a) Leak repair schedule. The owner...

  1. Using hyperspectral plant signatures for CO2 leak detection during the 2008 ZERT CO2 sequestration field experiment in Bozeman, Montana

    Energy Technology Data Exchange (ETDEWEB)

    Male, E.J.; Pickles, W.L.; Silver, E.A.; Hoffmann, G.D.; Lewicki, J.; Apple, M.; Repasky, K.; Burton, E.A.

    2009-11-01

    Hyperspectral plant signatures can be used as a short-term, as well as long-term (100-yr timescale) monitoring technique to verify that CO2 sequestration fields have not been compromised. An influx of CO2 gas into the soil can stress vegetation, which causes changes in the visible to nearinfrared reflectance spectral signature of the vegetation. For 29 days, beginning on July 9th, 2008, pure carbon dioxide gas was released through a 100-meter long horizontal injection well, at a flow rate of 300 kg/day. Spectral signatures were recorded almost daily from an unmown patch of plants over the injection with a ''FieldSpec Pro'' spectrometer by Analytical Spectral Devices, Inc. Measurements were taken both inside and outside of the CO2 leak zone to normalize observations for other environmental factors affecting the plants.

  2. Regulated tailored suction vs regulated seal: a prospective randomized trial on air leak duration.

    Science.gov (United States)

    Brunelli, Alessandro; Salati, Michele; Pompili, Cecilia; Refai, Majed; Sabbatini, Armando

    2013-05-01

    The objective of this study was to compare the air leak duration of two regulated chest tube modes following pulmonary lobectomy. This is a prospective randomized trial on 100 consecutive pulmonary lobectomies (2010-11) performed for lung cancer. A single 24-French chest tube was connected to an electronic system capable of maintaining the pleural pressure within preset values (regulated suction mode) or within a physiological range (regulated seal mode). Patients were randomized to two groups: Group 1, regulated individualized suction (range: -11 to -20 cmH2O, according to lobectomy type); Group 2, regulated seal (-2 cmH2O). The main endpoint was the duration of air leak (h) calculated from the end of the operation to a value consistently below 20 ml/min. Patients with prolonged air leak (>168 h) were connected to a portable device before discharge. Their air leak duration was considered as 192 h. The sample size was calculated to detect 1-day difference in air leak duration with a statistical power of 80%. The two groups were well matched for several baseline and surgical characteristics. No crossovers occurred between groups. The average air leak duration (Group 1: 28 vs Group 2: 22.2, P = 0.6), and the number of patients with prolonged air leak (Group 1: 5 vs Group 2: 4, P = 0.7) and with other complications (Group 1: 6 patients vs Group 2: 7 patients, P = 0.9) were similar between the groups. Sixteen patients of Group 1 and 21 of Group 2 had an air leak present immediately after extubation. Among them, patients of Group 2 (regulated seal) had an air leak lasting 34.5 h less than those of Group 1 (regulated suction) (52.9 vs 87.4, P = 0.07). Regulated seal is as effective and safe as regulated suction in managing chest tubes following lobectomy. This information demonstrates with objective data the non-superiority of regulated suction vs regulated seal and may assist in future investigations on regulated pleural pressure.

  3. APDS: Autonomous Pathogen Detection System

    Energy Technology Data Exchange (ETDEWEB)

    Langlois, R G; Brown, S; Burris, L; Colston, B; Jones, L; Makarewicz, T; Mariella, R; Masquelier, D; McBride, M; Milanovich, F; Masarabadi, S; Venkateswaran, K; Marshall, G; Olson, D; Wolcott, D

    2002-02-14

    An early warning system to counter bioterrorism, the Autonomous Pathogen Detection System (APDS) continuously monitors the environment for the presence of biological pathogens (e.g., anthrax) and once detected, it sounds an alarm much like a smoke detector warns of a fire. Long before September 11, 2001, this system was being developed to protect domestic venues and events including performing arts centers, mass transit systems, major sporting and entertainment events, and other high profile situations in which the public is at risk of becoming a target of bioterrorist attacks. Customizing off-the-shelf components and developing new components, a multidisciplinary team developed APDS, a stand-alone system for rapid, continuous monitoring of multiple airborne biological threat agents in the environment. The completely automated APDS samples the air, prepares fluid samples in-line, and performs two orthogonal tests: immunoassay and nucleic acid detection. When compared to competing technologies, APDS is unprecedented in terms of flexibility and system performance.

  4. Ferromagnetic Objects Magnetovision Detection System

    Directory of Open Access Journals (Sweden)

    Michał Nowicki

    2013-12-01

    Full Text Available This paper presents the application of a weak magnetic fields magnetovision scanning system for detection of dangerous ferromagnetic objects. A measurement system was developed and built to study the magnetic field vector distributions. The measurements of the Earth’s field distortions caused by various ferromagnetic objects were carried out. The ability for passive detection of hidden or buried dangerous objects and the determination of their location was demonstrated.

  5. 分布式光纤油气长输管道泄漏检测及预警技术%Distributed fiber oil and gas pipeline leak detection and warning technology

    Institute of Scientific and Technical Information of China (English)

    张富斌

    2015-01-01

    管道用于油气运输有着独特的优势,因此成为了运输油气的主要手段。在实际油气的运输过程中因为人为因素和自然因素等原因,经常会导致运输油气的管道发生泄漏事故,这不仅造成环境污染,而且会威胁到人们的生命财产安全。本文介绍了分布式光纤油气长输管道泄漏检测及预警技术在油田的应用。%For oil and gas transportation pipeline has a unique advantage, it became the primary means of transportation of oil and gas. In the actual transportation of oil and gas, man-made and natural factors and other reasons often resulted the transport of oil and gas pipeline leak accident, which not only affected environmental pollution, but also threatened people’s life and property safety.This article introduced distributed fiber oil and gas pipeline leak detection and warning technology.

  6. Automatic recovery from resource exhaustion exceptions by collecting leaked resources

    Institute of Scientific and Technical Information of China (English)

    Zi-ying DAI; Xiao-guang MAO; Li-qian CHEN; Yan LEI

    2014-01-01

    Despite the availability of garbage collectors, programmers must manually manage non-memory fi nite system resources such as fi le descriptors. Resource leaks can gradually consume all available resources and cause programs to raise resource exhaustion exceptions. However, programmers commonly provide no effective recovery approach for resource exhaustion exceptions, which often causes programs to halt without completing their tasks. In this paper, we propose to automatically recover programs from resource exhaustion exceptions caused by resource leaks. We transform programs to catch resource exhaustion exceptions, collect leaked resources, and then retry the failure code. A resource collector is designed to identify leaked resources and safely release them. We implement our approach for Java programs. Experimental results show that our approach can successfully handle resource exhaustion exceptions caused by reported resource leaks and allow programs to complete their tasks with an average execution time increase of 2.52%and negligible bytecode size increase.

  7. Fatal Primary Capillary Leak Syndrome in a Late Preterm Newborn.

    Science.gov (United States)

    Kulihova, Katarina; Prochazkova, Martina; Semberova, Jana; Janota, Jan

    2016-10-01

    Primary capillary leak syndrome is a rare disease of unknown etiology, characterized by episodes of vascular collapse and plasma extravasation, which may lead to multiple organ failure. Primary capillary leak is extremely rare in children. The authors report a case of a late preterm newborn with fatal capillary leak syndrome of unknown etiology, manifesting as hypotension unresponsive to treatment, extravasation leading to generalised edema, disseminated intravascular coagulation and finally, multiple organ dysfunction syndrome. Aggressive volumotherapy and a combination of inotropes and high doses of terlipressin did not influence systemic vascular collapse and plasma extravasation. The newborn developed multiple organ failure and died on day 27 of life. Investigations performed failed to reveal any specific cause of capillary leak. This is the first report of a fatal primary capillary leak syndrome in a newborn.

  8. Optimal pressure sensor placement for leak localisation using a relaxed isolation index : application to the Barcelona water network

    OpenAIRE

    Cugueró Escofet, Miquel Àngel; Puig Cayuela, Vicenç; Quevedo Casín, Joseba Jokin; Blesa Izquierdo, Joaquim

    2015-01-01

    Water distribution networks are large complex systems that are affected by leaks, which often entail high costs and may severely jeopardize the overall water distribution performance. Successful leak localisation is paramount in order to minimize the impact of these leaks when occurring. Sensor placement is a key issue in the leak localisation process, since the overall performance and success of the leak isolation method highly depends on the choice of the sensors gathering data from the net...

  9. Novel Fiber Optic Sensor Probe with a Pair of Highly Reflected Connectors and a Vessel of Water Absorption Material for Water Leak Detection

    Directory of Open Access Journals (Sweden)

    Tae-Sik Cho

    2012-08-01

    Full Text Available The use of a fiber optic quasi-distributed sensing technique for detecting the location and severity of water leakage is suggested. A novel fiber optic sensor probe is devised with a vessel of water absorption material called as water combination soil (WCS located between two highly reflected connectors: one is a reference connector and the other is a sensing connector. In this study, the sensing output is calculated from the reflected light signals of the two connectors. The first reflected light signal is a reference and the second is a sensing signal which is attenuated by the optical fiber bending loss due to the WCS expansion absorbing water. Also, the bending loss of each sensor probe is determined by referring to the total number of sensor probes and the total power budget of an entire system. We have investigated several probe characteristics to show the design feasibility of the novel fiber sensor probe. The effects of vessel sizes of the probes on the water detection sensitivity are studied. The largest vessel probe provides the highest sensitivity of 0.267 dB/mL, while the smallest shows relatively low sensitivity of 0.067 dB/mL, and unstable response. The sensor probe with a high output value provides a high sensitivity with various detection levels while the number of total installable sensor probes decreases.

  10. Development of a water leak detector system for LMFBR steam generator. Pt. 1; Sound attenuation due to bubbles

    Energy Technology Data Exchange (ETDEWEB)

    Kumagai, Hiromichi; Yoshida, Kazuo (Central Research Inst. of Electric Power Industry, Komae, Tokyo (Japan). Komae Research Lab.)

    1994-03-01

    In the steam generators (SG) of LMFBR, it is necessary to detect the leakage of water from tubes of heat exchanger as soon as leakage is occurred. The active acoustic detection method has drawn general interests owing to its short response time and reduction of the influence of background noise. In this paper, in order to study the applicability of active acoustic method for detection of water leakage in the SG, the sound attenuation characteristics due to bubbles are investigated under various bubble conditions and emitted sound conditions. Furthermore, using SG sector model, sound attenuation characteristics due to injection of bubbles are studied. As a result, it is clarified that the sound attenuation due to bubbles varies dependent upon size of bubbles, void fraction and thickness of bubble layer, that the attenuation of sound reaches maximum when bubbles resonate with the emitted frequency. The sound attenuation due to bubbles in the SG model attenuates immediately upon injection of bubbles, and sound attenuation depends upon bubble size as well as void fraction. (author).

  11. Intrusion Detection System: Security Monitoring System

    Directory of Open Access Journals (Sweden)

    ShabnamNoorani,

    2015-10-01

    Full Text Available An intrusion detection system (IDS is an ad hoc security solution to protect flawed computer systems. It works like a burglar alarm that goes off if someone tampers with or manages to get past other security mechanisms such as authentication mechanisms and firewalls. An Intrusion Detection System (IDS is a device or a software application that monitors network or system activities for malicious activities or policy violations and produces reports to a management station.Intrusion Detection System (IDS has been used as a vital instrument in defending the network from this malicious or abnormal activity..In this paper we are comparing host based and network based IDS and various types of attacks possible on IDS.

  12. Rapid, Vehicle-Based Identification of Location and Magnitude of Urban Natural Gas Pipeline Leaks.

    Science.gov (United States)

    von Fischer, Joseph C; Cooley, Daniel; Chamberlain, Sam; Gaylord, Adam; Griebenow, Claire J; Hamburg, Steven P; Salo, Jessica; Schumacher, Russ; Theobald, David; Ham, Jay

    2017-04-04

    Information about the location and magnitudes of natural gas (NG) leaks from urban distribution pipelines is important for minimizing greenhouse gas emissions and optimizing investment in pipeline management. To enable rapid collection of such data, we developed a relatively simple method using high-precision methane analyzers in Google Street View cars. Our data indicate that this automated leak survey system can document patterns in leak location and magnitude within and among cities, even without wind data. We found that urban areas with prevalent corrosion-prone distribution lines (Boston, MA, Staten Island, NY, and Syracuse, NY), leaked approximately 25-fold more methane than cities with more modern pipeline materials (Burlington, VT, and Indianapolis, IN). Although this mobile monitoring method produces conservative estimates of leak rates and leak counts, it can still help prioritize both leak repairs and replacement of leak-prone sections of distribution lines, thus minimizing methane emissions over short and long terms.

  13. Mine Safety Detection System (MSDS)

    Science.gov (United States)

    2012-09-01

    BLANK xiii LIST OF ACRONYMS AND ABBREVIATIONS Acronym Term ALMDS Airborne Laser -Mine Detection System AMCM Airborne Mine Countermeasure AoA...Streak Tube Imaging Laser ULCC Ultra Large Crude Carrier USN United States Navy UWIED Under Water Improvised Explosive Devices VLCC Very Large Crude...active sonar, passive sonar, infra-red (IR) thermal imaging, LIDAR (Light Detection and Ranging), and the use of marine mammals ( dolphins and porpoises

  14. A Study of Anti-leak System based on File Protection%一种基于文件保护的防泄密系统研究

    Institute of Scientific and Technical Information of China (English)

    刘思超; 张梓雄; 韩惠良; 孙国梓

    2013-01-01

    This article has carried on the analysis regarding the data security problem in the system, from the ifle protection perspective provides a solution, the design and implementation of a practical LAN ifle security control system, which realize the administrator can control only in a security system that a trusted host for editing and conifdential documents, to protect the stronger ability to prevent conifdential documents or data leaked. A trusted host security technology as well as the transparent encryption driver, the control end, the system administrator is analyzed.%文章对于系统中的数据安全问题进行了分析,从文件保护的角度提供了一种解决方案,设计与实现了一个具有实用性的局域网内文件安全管控系统,即实现管理员可以控制的仅能够在指定的受信主机上进行机密文件的编辑与修改的安全系统,达到更强的防止机密文件或者数据被泄露的保护能力。文章还对系统中的管理员控制端、受信主机安全技术以及透明加解密驱动程序等进行了分析。

  15. Fugitive methane leak detection using mid-infrared hollow-core photonic crystal fiber containing ultrafast laser drilled side-holes

    Science.gov (United States)

    Karp, Jason; Challener, William; Kasten, Matthias; Choudhury, Niloy; Palit, Sabarni; Pickrell, Gary; Homa, Daniel; Floyd, Adam; Cheng, Yujie; Yu, Fei; Knight, Jonathan

    2016-05-01

    The increase in domestic natural gas production has brought attention to the environmental impacts of persistent gas leakages. The desire to identify fugitive gas emission, specifically for methane, presents new sensing challenges within the production and distribution supply chain. A spectroscopic gas sensing solution would ideally combine a long optical path length for high sensitivity and distributed detection over large areas. Specialty micro-structured fiber with a hollow core can exhibit a relatively low attenuation at mid-infrared wavelengths where methane has strong absorption lines. Methane diffusion into the hollow core is enabled by machining side-holes along the fiber length through ultrafast laser drilling methods. The complete system provides hundreds of meters of optical path for routing along well pads and pipelines while being interrogated by a single laser and detector. This work will present transmission and methane detection capabilities of mid-infrared photonic crystal fibers. Side-hole drilling techniques for methane diffusion will be highlighted as a means to convert hollow-core fibers into applicable gas sensors.

  16. 生物安全实验室效率检漏型高效空气过滤装置的研制%Development of HEPA Filter Unit with Efficiency Leak Detection for Bio-safety Laboratory

    Institute of Scientific and Technical Information of China (English)

    张宗兴; 赵明; 衣颖; 祁建城

    2013-01-01

    目的:研制一种可安装在生物安全实验室内的效率检漏型排风高效过滤装置,可实现对高效空气过滤器的原位检漏和消毒.方法:依据高效空气过滤器效率法检测和气体消毒要求,进行高效空气过滤装置的结构设计.结果:该高效空气过滤装置,可采用效率法对高效过滤器进行原位检漏,并可对过滤器进行原位气体消毒及验证消毒效果,满足相关标准要求.结论:该装置适用于生物安全实验室的污染空气排放处置,可满足我国生物安全实验室建设的需要.%Objective To develop an exhaust HEPA filter unit installed in the laboratory that has the functions of in-situ leak detection and sterilization of HEPA filter.Methods The structure composition of the unit was designed according to the requirement of efficiency test and gas sterilization of HEPA filter.Results The HEPA filter unit which met relevant standard requirements had the functions of in-situ leak detection using efficiency test,sterilization and validating the effect of sterilization of HEPA filter.Conclusion The unit which is applicable to decontamination of contaminated air emissions of bio-safety laboratory can meet the needs of construction of bio-safety laboratory in China.

  17. Intelligent System for Worm Detection

    Directory of Open Access Journals (Sweden)

    Tarek S. Sobh

    2009-01-01

    Full Text Available Worms are on the top of malware threats attacking computer system although of the evolution of worms detectiontechniques. Early detection of unknown worms is still a problem. This paper produce a method for detecting unknown wormsbased on local victim information. The proposed system uses Artificial Neural Network (ANN for classifying worm/ nonwormtraffic and predicting the percentage of infection in the infected network. This prediction can be used to support decisionmaking process for network administrator to respond quickly to worm propagation in an accurate procedure.

  18. POF hydrogen detection sensor systems for launch vehicles applications

    Science.gov (United States)

    Kazemi, Alex A.; Larson, David B.; Wuestling, Mark D.

    2011-06-01

    This paper describes the first successful Plastic Optical Fiber (POF) cable and glass fiber hydrogen detection sensor systems developed for Delta IV Launch Vehicle. Hydrogen detection in space application is very challenging; the hydrogen detection is priority for rocket industry and every transport device or any application where hydrogen is involved. H2 sensors are necessary to monitor the detection possible leak to avoid explosion, which can be highly dangerous. The hydrogen sensors had to perform in temperatures between -18° C to 60° C (0° F to 140° F). The response of the sensor in this temperature regime was characterized to ensure proper response of the sensors to fugitive hydrogen leakage during vehicle ground operations. We developed the first 75 m combination of POF and glass fiber H2 sensors. Performed detail investigation of POF-glass cables for attenuation loss, thermal, humidity, temperature, shock, accelerate testing for life expectancy. Also evaluated absorption, operating and high/low temperatures, and harsh environmental for glass-POF cables connectors. The same test procedures were performed for glass multi mode fiber part of the H2 and O2 sensors. A new optical waveguides was designed and developed to decrease the impact of both noise and long term drift of sensor. A field testing of sensors was performed at NASA Stennis on the Aerospike X-33 to quantify the element of the sensor package that was responsible for hydrogen detection and temperature.

  19. Leak testing of cryogenic components - problems and solutions

    Energy Technology Data Exchange (ETDEWEB)

    Srivastava, S P; Pandarkar, S P; Unni, T G; Sinha, A K; Mahajan, K; Suthar, R L [Centre for Design and Manufacture, Bhabha Atomic Research Centre, Mumbai 400085 (India)], E-mail: sushils@barc.gov.in

    2008-05-01

    A prototype of Cold Neutron Source (CNS) for Dhruva Reactor is being manufactured at Centre for Design and Manufacture (CDM), BARC, Mumbai for validating the mechanical and thermal engineering design aspects, besides checking the integrity of all joints and components at low temperature, 77K. Task of a Cold Neutron Source is to generate cold neutrons by cooling down the thermal neutrons, which are originally produced in a nuclear research reactor. The complete Cold Neutron Source system comprises a complex arrangement of moderator pot, transfer line (piping), pumps, refrigerators, storage tanks, a heat exchanger and associated controls and instrumentation. The heart of the system is moderator pot in which water (moderator) is cooled down by Liquid Nitrogen (LN{sub 2}) being circulated through an annular cavity machined on the walls of the pot. Transfer lines for LN{sub 2} basically consist of two concentric Stainless Steel flexible pipes, which are joined to the inlet and outlet Aluminium tubes of the moderator pot through transition joints. Leak in any component may result in loss of liquid Nitrogen, degradation of vacuum, which in turn may affect the heat removal efficiency of the source. Hence, leak testing was considered a very important quality control tool and all joints and components were subjected to helium leak test using mass spectrometer leak detector (MSLD) at cryogenic temperature. During one of the earlier experiments, flow of LN{sub 2} through inner flexible pipe of the transfer line resulted in rise of pressure in the vacuum annulus and sweating on the outer flexible pipe. After investigations it was found that large thermal stress compounded with mechanical stress resulted in cracks in the inner pipe. Accordingly design was modified to get leak proof transfer line assembly. Further, during leak testing of thin wall moderator pot, gross leak was observed on the outer jacket welded joint. Leak was so large that even a small amount of Helium gas in

  20. Leak testing of cryogenic components — problems and solutions

    Science.gov (United States)

    Srivastava, S. P.; Pandarkar, S. P.; Unni, T. G.; Sinha, A. K.; Mahajan, K.; Suthar, R. L.

    2008-05-01

    A prototype of Cold Neutron Source (CNS) for Dhruva Reactor is being manufactured at Centre for Design and Manufacture (CDM), BARC, Mumbai for validating the mechanical and thermal engineering design aspects, besides checking the integrity of all joints and components at low temperature, 77K. Task of a Cold Neutron Source is to generate cold neutrons by cooling down the thermal neutrons, which are originally produced in a nuclear research reactor. The complete Cold Neutron Source system comprises a complex arrangement of moderator pot, transfer line (piping), pumps, refrigerators, storage tanks, a heat exchanger and associated controls and instrumentation. The heart of the system is moderator pot in which water (moderator) is cooled down by Liquid Nitrogen (LN2) being circulated through an annular cavity machined on the walls of the pot. Transfer lines for LN2 basically consist of two concentric Stainless Steel flexible pipes, which are joined to the inlet and outlet Aluminium tubes of the moderator pot through transition joints. Leak in any component may result in loss of liquid Nitrogen, degradation of vacuum, which in turn may affect the heat removal efficiency of the source. Hence, leak testing was considered a very important quality control tool and all joints and components were subjected to helium leak test using mass spectrometer leak detector (MSLD) at cryogenic temperature. During one of the earlier experiments, flow of LN2 through inner flexible pipe of the transfer line resulted in rise of pressure in the vacuum annulus and sweating on the outer flexible pipe. After investigations it was found that large thermal stress compounded with mechanical stress resulted in cracks in the inner pipe. Accordingly design was modified to get leak proof transfer line assembly. Further, during leak testing of thin wall moderator pot, gross leak was observed on the outer jacket welded joint. Leak was so large that even a small amount of Helium gas in the vicinity of the

  1. Controlled biological and biomimetic systems for landmine detection.

    Science.gov (United States)

    Habib, Maki K

    2007-08-30

    Humanitarian demining requires to accurately detect, locate and deactivate every single landmine and other buried mine-like objects as safely and as quickly as possible, and in the most non-invasive manner. The quality of landmine detection affects directly the efficiency and safety of this process. Most of the available methods to detect explosives and landmines are limited by their sensitivity and/or operational complexities. All landmines leak with time small amounts of their explosives that can be found on surrounding ground and plant life. Hence, explosive signatures represent the robust primary indicator of landmines. Accordingly, developing innovative technologies and efficient techniques to identify in real-time explosives residue in mined areas represents an attractive and promising approach. Biological and biologically inspired detection technology has the potential to compete with or be used in conjunction with other artificial technology to complement performance strengths. Biological systems are sensitive to many different scents concurrently, a property that has proven difficult to replicate artificially. Understanding biological systems presents unique opportunities for developing new capabilities through direct use of trained bio-systems, integration of living and non-living components, or inspiring new design by mimicking biological capabilities. It is expected that controlled bio-systems, biotechnology and microbial techniques will contribute to the advancement of mine detection and other application domains. This paper provides directions, evaluation and analysis on the progress of controlled biological and biomimetic systems for landmine detection. It introduces and discusses different approaches developed, underlining their relative advantages and limitations, and highlighting trends, safety and ecology concern, and possible future directions.

  2. Quantifying Urban Natural Gas Leaks from Street-level Methane Mapping: Measurements and Uncertainty

    Science.gov (United States)

    von Fischer, J. C.; Ham, J. M.; Griebenow, C.; Schumacher, R. S.; Salo, J.

    2013-12-01

    Leaks from the natural gas pipeline system are a significant source of anthropogenic methane in urban settings. Detecting and repairing these leaks will reduce the energy and carbon footprints of our cities. Gas leaks can be detected from spikes in street-level methane concentrations measured by analyzers deployed on vehicles. While a spike in methane concentration indicates a leak, an algorithm (e.g., inverse model) must be used to estimate the size of the leak (i.e., flux) from concentration data and supporting meteorological information. Unfortunately, this drive-by approach to leak quantification is confounded by the complexity of urban roughness, changing weather conditions, and other incidental factors (e.g., traffic, vehicle speed, etc.). Furthermore, the vehicle might only pass through the plume one to three times during routine mapping. The objective of this study was to conduct controlled release experiments to better quantify the relationship between mobile methane concentration measurements and the size and location of the emission source (e.g., pipeline leakage) in an urban environment. A portable system was developed that could release methane at known rates between 10 and 40 LPM while maintaining concentrations below the lower explosive limit. A mapping vehicle was configured with fast response methane analyzers, GPS, and meteorological instruments. Portable air-sampling tripods were fabricated that could be deployed at defined distances downwind from the release point and automatically-triggered to collect grab samples. The experimental protocol was as follows: (1) identify an appropriate release point within a city, (2) release methane at a known rate, (3) measure downwind street-level concentrations with the vehicle by making multiple passes through the plume, and (4) collect supporting concentration and meteorological data with the static tripod samplers deployed in the plume. Controlled release studies were performed at multiple locations and

  3. Quickest detection in coupled systems

    CERN Document Server

    Hadjiliadis, Olympia; Poor, H Vincent

    2009-01-01

    This work considers the problem of quickest detection of signals in a coupled system of N sensors, which receive continuous sequential observations from the environment. It is assumed that the signals, which are modeled a general Ito processes, are coupled across sensors, but that their onset times may differ from sensor to sensor. The objective is the optimal detection of the first time at which any sensor in the system receives a signal. The problem is formulated as a stochastic optimization problem in which an extended average Kullback- Leibler divergence criterion is used as a measure of detection delay, with a constraint on the mean time between false alarms. The case in which the sensors employ cumulative sum (CUSUM) strategies is considered, and it is proved that the minimum of N CUSUMs is asymptotically optimal as the mean time between false alarms increases without bound.

  4. System for detecting microbial contamination

    NARCIS (Netherlands)

    Gerritse, J.; Groenestijn, J.W.; Zegers, N.D.

    2009-01-01

    The present invention relates to a system for detecting microbial contamination of a liquid specimen comprising a device for concentrating micro-organisms from a liquid specimen, having (i) a hypobaric chamber, (ii) a filter housing comprising a liquid-permeable bed of an adsorbent material and adap

  5. Semi autonomous mine detection system

    Energy Technology Data Exchange (ETDEWEB)

    Douglas Few; Roelof Versteeg; Herman Herman

    2010-04-01

    CMMAD is a risk reduction effort for the AMDS program. As part of CMMAD, multiple instances of semi autonomous robotic mine detection systems were created. Each instance consists of a robotic vehicle equipped with sensors required for navigation and marking, a countermine sensors and a number of integrated software packages which provide for real time processing of the countermine sensor data as well as integrated control of the robotic vehicle, the sensor actuator and the sensor. These systems were used to investigate critical interest functions (CIF) related to countermine robotic systems. To address the autonomy CIF, the INL developed RIK was extended to allow for interaction with a mine sensor processing code (MSPC). In limited field testing this system performed well in detecting, marking and avoiding both AT and AP mines. Based on the results of the CMMAD investigation we conclude that autonomous robotic mine detection is feasible. In addition, CMMAD contributed critical technical advances with regard to sensing, data processing and sensor manipulation, which will advance the performance of future fieldable systems. As a result, no substantial technical barriers exist which preclude – from an autonomous robotic perspective – the rapid development and deployment of fieldable systems.

  6. Semi autonomous mine detection system

    Science.gov (United States)

    Few, Doug; Versteeg, Roelof; Herman, Herman

    2010-04-01

    CMMAD is a risk reduction effort for the AMDS program. As part of CMMAD, multiple instances of semi autonomous robotic mine detection systems were created. Each instance consists of a robotic vehicle equipped with sensors required for navigation and marking, countermine sensors and a number of integrated software packages which provide for real time processing of the countermine sensor data as well as integrated control of the robotic vehicle, the sensor actuator and the sensor. These systems were used to investigate critical interest functions (CIF) related to countermine robotic systems. To address the autonomy CIF, the INL developed RIK was extended to allow for interaction with a mine sensor processing code (MSPC). In limited field testing this system performed well in detecting, marking and avoiding both AT and AP mines. Based on the results of the CMMAD investigation we conclude that autonomous robotic mine detection is feasible. In addition, CMMAD contributed critical technical advances with regard to sensing, data processing and sensor manipulation, which will advance the performance of future fieldable systems. As a result, no substantial technical barriers exist which preclude - from an autonomous robotic perspective - the rapid development and deployment of fieldable systems.

  7. The pump and leak steady-state concept with a variety of regulated leak pathways

    DEFF Research Database (Denmark)

    Hoffmann, E K

    2001-01-01

    found that the passive ion leaks play an active role in cell volume control. (iii) The use of isotopes and Ussing's famous flux ratio equation provided an ingenious instrument for distinguishing the various transport routes. We used this to identify the Na,K,2Cl cotransport system as accounting...

  8. Design of vacuum leak testing management system for spacecraft component test%航天器部件真空检漏试验管理系统的设计

    Institute of Scientific and Technical Information of China (English)

    汪力; 郑江滨; 闫荣鑫; 张海英

    2012-01-01

    The design method of the vacuum leak testing management system for spacecraft components is discussed in this paper.The vacuum leak testing management system for spacecraft components is an essential subsystem of the special environment test management system for spacecraft components.According to the requirements of the vacuum leak testing management system for spacecraft components and the software development process, the test processes are analyzed and the overall structure and various functionality modules are designed.The testing management system is divided into three mutually supporting levels: the user service tier, the business logic tier and the data resources tier.There are seven functional modules in the spacecraft component vacuum leak testing management system, including the test task management, the personal task management, the test data management, the test file management, the test resource management, the configuration management and the system management.This system would be helpful to a more efficient and reasonable management of vacuum leak testing for spacecraft components.%航天器部件真空检漏试验管理系统是航天器件特殊环境试验管理系统的一个重要组成部分.文章根据航天器部件真空检漏试验管理的需求,结合软件设计开发流程规范,对试验技术流程进行了分析,设计出系统总体框架和功能模块:系统总体框架分为数据资源层、业务逻辑层和客户层;功能模块分为试验任务管理模块、个人任务管理模块、试验数据管理模块、试验归档管理模块、试验资源管理模块、基础配置管理模块和系统管理模块.该试验管理系统将使航天器部件真空检漏试验管理工作更加高效、合理.

  9. Natural gas pipeline leaks across Washington, DC.

    Science.gov (United States)

    Jackson, Robert B; Down, Adrian; Phillips, Nathan G; Ackley, Robert C; Cook, Charles W; Plata, Desiree L; Zhao, Kaiguang

    2014-01-01

    Pipeline safety in the United States has increased in recent decades, but incidents involving natural gas pipelines still cause an average of 17 fatalities and $133 M in property damage annually. Natural gas leaks are also the largest anthropogenic source of the greenhouse gas methane (CH4) in the U.S. To reduce pipeline leakage and increase consumer safety, we deployed a Picarro G2301 Cavity Ring-Down Spectrometer in a car, mapping 5893 natural gas leaks (2.5 to 88.6 ppm CH4) across 1500 road miles of Washington, DC. The δ(13)C-isotopic signatures of the methane (-38.2‰ ± 3.9‰ s.d.) and ethane (-36.5 ± 1.1 s.d.) and the CH4:C2H6 ratios (25.5 ± 8.9 s.d.) closely matched the pipeline gas (-39.0‰ and -36.2‰ for methane and ethane; 19.0 for CH4/C2H6). Emissions from four street leaks ranged from 9200 to 38,200 L CH4 day(-1) each, comparable to natural gas used by 1.7 to 7.0 homes, respectively. At 19 tested locations, 12 potentially explosive (Grade 1) methane concentrations of 50,000 to 500,000 ppm were detected in manholes. Financial incentives and targeted programs among companies, public utility commissions, and scientists to reduce leaks and replace old cast-iron pipes will improve consumer safety and air quality, save money, and lower greenhouse gas emissions.

  10. Adaptive Kalman Filter Based on Adjustable Sampling Interval in Burst Detection for Water Distribution System

    Directory of Open Access Journals (Sweden)

    Doo Yong Choi

    2016-04-01

    Full Text Available Rapid detection of bursts and leaks in water distribution systems (WDSs can reduce the social and economic costs incurred through direct loss of water into the ground, additional energy demand for water supply, and service interruptions. Many real-time burst detection models have been developed in accordance with the use of supervisory control and data acquisition (SCADA systems and the establishment of district meter areas (DMAs. Nonetheless, no consideration has been given to how frequently a flow meter measures and transmits data for predicting breaks and leaks in pipes. This paper analyzes the effect of sampling interval when an adaptive Kalman filter is used for detecting bursts in a WDS. A new sampling algorithm is presented that adjusts the sampling interval depending on the normalized residuals of flow after filtering. The proposed algorithm is applied to a virtual sinusoidal flow curve and real DMA flow data obtained from Jeongeup city in South Korea. The simulation results prove that the self-adjusting algorithm for determining the sampling interval is efficient and maintains reasonable accuracy in burst detection. The proposed sampling method has a significant potential for water utilities to build and operate real-time DMA monitoring systems combined with smart customer metering systems.

  11. Lightning Protection and Detection System

    Science.gov (United States)

    Dudley, Kenneth L. (Inventor); Szatkowski, George N. (Inventor); Woodard, Marie (Inventor); Nguyen, Truong X. (Inventor); Ely, Jay J. (Inventor); Wang, Chuantong (Inventor); Mielnik, John J. (Inventor); Koppen, Sandra V. (Inventor); Smith, Laura J. (Inventor)

    2017-01-01

    A lightning protection and detection system includes a non-conductive substrate material of an apparatus; a sensor formed of a conductive material and deposited on the non-conductive substrate material of the apparatus. The sensor includes a conductive trace formed in a continuous spiral winding starting at a first end at a center region of the sensor and ending at a second end at an outer corner region of the sensor, the first and second ends being open and unconnected. An electrical measurement system is in communication with the sensor and receives a resonant response from the sensor, to perform detection, in real-time, of lightning strike occurrences and damage therefrom to the sensor and the non-conductive substrate material.

  12. Optical detection in microfluidic systems

    DEFF Research Database (Denmark)

    Mogensen, Klaus Bo; Kutter, Jörg Peter

    2009-01-01

    Optical detection schemes continue to be favoured for measurements in microfluidic systems. A selection of the latest progress mainly within the last two years is critically reviewed. Emphasis is on integrated solutions, such as planar waveguides, coupling schemes to the outside world, evanescent...... to ease commercialisation of the devices. This work will hopefully result in more commercial products that benefit from integrated optics, because the impact on commercial devices so far has been modest....

  13. Gastric Cancer Regional Detection System.

    Science.gov (United States)

    Ural, Berkan; Hardalaç, Fırat; Serhatlioğlu, Selami; İlhan, Mustafa Necmi

    2016-01-01

    In this study, a novel system was created to localize cancerous regions for stomach images which were taken with computed tomography(CT). The aim was to determine the coordinates of cancerous regions which spread in the stomach area in the color space with using this system. Also, to limit these areas with a high accuracy ratio and to feedback to the user of this system were the other objectives. This integration was performed with using energy mapping, analysis methods and multiple image processing methods and the system which was consisted from these advanced algorithms was appeared. For this work, in the range of 25-40 years and when gender discrimination was insignificant, 30 volunteer patients were chosen. During the formation of the system, to exalt the accuracy to the maximum level, 2 main stages were followed up. First, in the system, advanced image processing methods were processed between each other and obtained data were studied. Second, in the system, FFT and Log transformations were used respectively for the first two cases, then these transformations were used together for the third case. For totally three cases, energy distribution and DC energy intensity analysis were done and the performance of this system was investigated. Finally, with using the system's unique algorithms, a non-invasive method was achieved to detect the gastric cancer and when FFT and Log transformation were used together, the maximum success rate was obtained and this rate was calculated as 83,3119 %.

  14. The Autonomous Pathogen Detection System

    Energy Technology Data Exchange (ETDEWEB)

    Dzenitis, J M; Makarewicz, A J

    2009-01-13

    We developed, tested, and now operate a civilian biological defense capability that continuously monitors the air for biological threat agents. The Autonomous Pathogen Detection System (APDS) collects, prepares, reads, analyzes, and reports results of multiplexed immunoassays and multiplexed PCR assays using Luminex{copyright} xMAP technology and flow cytometer. The mission we conduct is particularly demanding: continuous monitoring, multiple threat agents, high sensitivity, challenging environments, and ultimately extremely low false positive rates. Here, we introduce the mission requirements and metrics, show the system engineering and analysis framework, and describe the progress to date including early development and current status.

  15. Nucleic acid detection system and method for detecting influenza

    Science.gov (United States)

    Cai, Hong; Song, Jian

    2015-03-17

    The invention provides a rapid, sensitive and specific nucleic acid detection system which utilizes isothermal nucleic acid amplification in combination with a lateral flow chromatographic device, or DNA dipstick, for DNA-hybridization detection. The system of the invention requires no complex instrumentation or electronic hardware, and provides a low cost nucleic acid detection system suitable for highly sensitive pathogen detection. Hybridization to single-stranded DNA amplification products using the system of the invention provides a sensitive and specific means by which assays can be multiplexed for the detection of multiple target sequences.

  16. Nucleic acid detection system and method for detecting influenza

    Energy Technology Data Exchange (ETDEWEB)

    Cai, Hong; Song, Jian

    2015-03-17

    The invention provides a rapid, sensitive and specific nucleic acid detection system which utilizes isothermal nucleic acid amplification in combination with a lateral flow chromatographic device, or DNA dipstick, for DNA-hybridization detection. The system of the invention requires no complex instrumentation or electronic hardware, and provides a low cost nucleic acid detection system suitable for highly sensitive pathogen detection. Hybridization to single-stranded DNA amplification products using the system of the invention provides a sensitive and specific means by which assays can be multiplexed for the detection of multiple target sequences.

  17. Capillary Electrophoresis - Optical Detection Systems

    Energy Technology Data Exchange (ETDEWEB)

    Sepaniak, M. J.

    2001-08-06

    Molecular recognition systems are developed via molecular modeling and synthesis to enhance separation performance in capillary electrophoresis and optical detection methods for capillary electrophoresis. The underpinning theme of our work is the rational design and development of molecular recognition systems in chemical separations and analysis. There have been, however, some subtle and exciting shifts in our research paradigm during this period. Specifically, we have moved from mostly separations research to a good balance between separations and spectroscopic detection for separations. This shift is based on our perception that the pressing research challenges and needs in capillary electrophoresis and electrokinetic chromatography relate to the persistent detection and flow rate reproducibility limitations of these techniques (see page 1 of the accompanying Renewal Application for further discussion). In most of our work molecular recognition reagents are employed to provide selectivity and enhance performance. Also, an emerging trend is the use of these reagents with specially-prepared nano-scale materials. Although not part of our DOE BES-supported work, the modeling and synthesis of new receptors has indirectly supported the development of novel microcantilevers-based MEMS for the sensing of vapor and liquid phase analytes. This fortuitous overlap is briefly covered in this report. Several of the more significant publications that have resulted from our work are appended. To facilitate brevity we refer to these publications liberally in this progress report. Reference is also made to very recent work in the Background and Preliminary Studies Section of the Renewal Application.

  18. Compensated intruder-detection systems

    Science.gov (United States)

    McNeilly, David R.; Miller, William R.

    1984-01-01

    Intruder-detection systems in which intruder-induced signals are transmitted through a medium also receive spurious signals induced by changes in a climatic condition affecting the medium. To combat this, signals received from the detection medium are converted to a first signal. The system also provides a reference signal proportional to climate-induced changes in the medium. The first signal and the reference signal are combined for generating therefrom an output signal which is insensitive to the climatic changes in the medium. An alarm is energized if the output signal exceeds a preselected value. In one embodiment, an acoustic cable is coupled to a fence to generate a first electrical signal proportional to movements thereof. False alarms resulting from wind-induced movements of the fence (detection medium) are eliminated by providing an anemometer-driven voltage generator to provide a reference voltage proportional to the velocity of wind incident on the fence. An analog divider receives the first electrical signal and the reference signal as its numerator and denominator inputs, respectively, and generates therefrom an output signal which is insensitive to the wind-induced movements in the fence.

  19. 基于局部堆内存抽象表示的堆操作程序内存泄露检测%Memory Leak Detection for Heap-Manipulating Programs Based on Local Heap Abstraction

    Institute of Scientific and Technical Information of China (English)

    董龙明; 王戟; 陈立前; 董威

    2012-01-01

    There are many operations about shared and mutable data structures in heap-manipulating programs, such as allocation, combination, separation, deletion, and so on. Therefore, memory leak detection for these programs requires precise field-sensitive pointer alias information, which becomes more complex and harder to deal with. A novel field-sensitive heap abstraction approach based on extended pointer types is proposed for heap-manipulating programs in this paper. The approach computes the local layout around pointer variables in the heap, and therefore supports local reasoning for heap. The pointer alias sets are computed about the memory cells, which are reached by the pointer along various pointer fields in the given abstract distance domain. Various operation semantics about all basic statements based on extended pointer types are defined and a new algorithm runs typical forward dataflow iteration analysis to see whether there are any memory leaks. Our algorithm also supports both intra- and inter- procedural analysis. We have implemented the prototype tool (Heapcheck) for C programs in the Crystal open compiler framework to support detecting memory leaks about different pointer fields in complex data structures. Experimental evaluation about a set of C benchmark programs shows that the proposed approach has better scalability and precision than current work.%堆操作程序通过共享易变数据结构可灵活地申请、合并、删除堆内存.这类程序的内存泄漏检测要求精确的域敏感的指针别名信息,变得尤其复杂和难以处理.针对这个问题,提出了基于“指针扩展类型”域敏感的堆内存抽象方法,对指针变量在形态上的排列关系进行抽象以支持堆的局部推理.首先,定义了各种基本语句的操作语义,然后基于该抽象方法采用前向数据流迭代算法提出了一种新的内存泄露检测算法.在Crystal编译框架下实现了面向C程序的内存泄漏检测原型工

  20. Leak testing of IR sensor dewars to 1E-15 std He/s

    Science.gov (United States)

    Sasaki, Y. Tito; Bergquist, Lyle E.

    1990-09-01

    The results of tests for leakage performed on ten IR sensor dewars are presented, and the design principles of the new testing devices are discussed. The ultrasensitive leak detector used for testing is compared to conventional detectors. The superfine leak calibrator consisting of a tracer gas supply, an aliquot volume, a pressure transducer, temperature gage, and valves was used to measure leak rates in the E-4 to E-12 std cc He/s range. The testing method is explained, including the gases used, the quadrupole mass analyzer, the reference leak calibration, and the temperature coefficient of the reference leak. The test results of the IR sensor dewars are shown: seven showed leak rates in the E-15 std cc He/s range, two had no detectable leaks, and one had a mid-range E-14 leak. The shelf lives of the dewars are calculated based on the results. The vacuum integrity of small IR sensor dewars can be reliably tested to the range of 1E-15 std cc He/s using the ultrasensitive leak detector and the superfine leak calibrator.

  1. Study of Internal and External Leaks in Tests of Anode-Supported SOFCs

    DEFF Research Database (Denmark)

    Rasmussen, Jens Foldager Bregnballe; Hendriksen, Peter Vang; Hagen, Anke

    2008-01-01

    A planar anode-supported solid oxide fuel cell (SOFC) has been tested to investigate gas tightness of the electrolyte and the applied seals. Gas leaks reduce the efficiency of the SOFC and it is thus important to determine and minimise them. Probe gases (He and Ar) and a Quadrupole Mass Spectrome......A planar anode-supported solid oxide fuel cell (SOFC) has been tested to investigate gas tightness of the electrolyte and the applied seals. Gas leaks reduce the efficiency of the SOFC and it is thus important to determine and minimise them. Probe gases (He and Ar) and a Quadrupole Mass...... Spectrometer were used to detect both internal (through electrolyte) and external (through seals) gas leaks. The internal gas leak through the electrolyte was quantified under different conditions, as was the external leak from the surroundings to the anode. The internal gas leak did not depend on the pressure...... and pressure gradients. The measured gas leaks deduced from the probe gas experiments and the total leak calculated from the deviation between the Emf defined by the gases and the cell OCV (which contains all gas leaks as well as effects of electronic leaks) were compared. Good agreement between the two...

  2. Explosives detection system and method

    Science.gov (United States)

    Reber, Edward L.; Jewell, James K.; Rohde, Kenneth W.; Seabury, Edward H.; Blackwood, Larry G.; Edwards, Andrew J.; Derr, Kurt W.

    2007-12-11

    A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.

  3. Variable gas leak rate valve

    Energy Technology Data Exchange (ETDEWEB)

    Eernisse, Errol P. (Albuquerque, NM); Peterson, Gary D. (Albuquerque, NM)

    1976-01-01

    A variable gas leak rate valve which utilizes a poled piezoelectric element to control opening and closing of the valve. The gas flow may be around a cylindrical rod with a tubular piezoelectric member encircling the rod for seating thereagainst to block passage of gas and for reopening thereof upon application of suitable electrical fields.

  4. Development of a General Method for Determining Leak Rates from Limiting Enclosures

    Science.gov (United States)

    Zografos, A. I.; Blackwell, C. C.; Harper, Lynn D. (Technical Monitor)

    1994-01-01

    This paper discusses the development of a general method for the determination of very low leak rates from limiting enclosures. There are many methods that can be used to detect and repair leaks from enclosures. Many methods have also been proposed that allow the estimation of actual leak rates, usually expressed as enclosure volume turnover. The proposed method combines measurements of the state variables (pressure, temperature, and volume) as well as the change in the concentration of a tracer gas to estimate the leak rate. The method was applied to the containment enclosure of the Engineering Development Unit of the CELSS Test Facility, currently undergoing testing at the NASA Ames Research Center.

  5. The leak microstructure

    Indian Academy of Sciences (India)

    M Lombardi; C Baiocchi; A Battistella; G Balbinot; H Huo-Ja Guoxiang; F S Lombardi

    2001-07-01

    The capabilities of a new microstructure, anode point based, for the detection of gas ionizing radiations are presented. For every single detected ionizing radiation it gives a pair of ‘induced’ charges (anodic and cathodic) of the same amount (pulses of the same amplitudes), of opposite sign, with the same collection time and essentially in time coincidence, that are proportional to the primary ionization collected. Each pulse of a pair gives the same energy and timing information, thus one can be used for these information and the other for the position. The complete lack of insulating materials in the active volume of this microstructure avoids problems of charging-up and makes stable and repeatable its behavior. It is possible to observe primary avalanches with a size of more than 2.5 × 107 electrons (4 pC), which give current pulses with a peak of more than 0.26 mA on 100 Ohm and about 30 ns duration, with 5.9 KeV X-rays of 55Fe working in proportional region in 760 Torr of isobutane gas. Single electrons emitted by a heated filament ( < 1~ eV) can also be detected in 760 Torr of isobutane; with an estimated gas gain of 1.2 × 106 and a counting rate up to 800 Kpulses/sec per single microstructure. Some new features and three different types of sensitive-position two-dimensional read-out detectors based on these microstructures, which are in developmental stage, are presented.

  6. Presidential Leaks: Rhetoric and Mediated Political Knowledge.

    Science.gov (United States)

    Erickson, Keith V.

    1989-01-01

    Argues that presidential leaks constitute rhetorical acts, enabling administrations to exercise a variety of rhetorically potent options not afforded by the public forum. Proposes a typology of presidential leaks and analyzes their rhetorical functions, benefits, and liabilities. (MM)

  7. Stochastic Consequence Analysis for Waste Leaks

    Energy Technology Data Exchange (ETDEWEB)

    HEY, B.E.

    2000-05-31

    This analysis evaluates the radiological consequences of potential Hanford Tank Farm waste transfer leaks. These include ex-tank leaks into structures, underneath the soil, and exposed to the atmosphere. It also includes potential misroutes, tank overflow

  8. CT findings suggesting anastomotic leak and predicting the recovery period following gastric surgery

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Ho; Kim, Jung Hoon; Shin, Cheong-Il; Kim, Se Hyung; Han, Joon Koo; Choi, Byung Ihn [Seoul National University College of Medicine, Department of Radiology, Institute of Radiation Medicine, Jongno-gu, Seoul (Korea, Republic of)

    2015-07-15

    To assess diagnostic performance of routine CT for detecting anastomotic leak after gastric surgery, and analyse the relationship between recovery period and CT findings. We included 179 patients who underwent immediate CT and fluoroscopy after gastric surgery. Two reviewers retrospectively rated the possibility of leak on CT using a five-point scale focused on predefined CT findings. They also evaluated CT findings. Patients were categorised as: Group I, leak on fluoroscopy; Group II, possible leak on CT but negative on fluoroscopy; Group III, no leak. We analysed the relationship between recovery period and group. Area under the curve for detecting leak on CT was 0.886 in R1 and 0.668 in R2 with moderate agreement (k = 0.482). Statistically common CT findings for leak included discontinuity, large amount of air-fluid and wall thickening at anastomosis site (p < 0.05). Discontinuity at anastomosis site and a large air-fluid collection were independently associated with leak (p < 0.05). The recovery period including hospitalisation and postoperative fasting period was longer in Group I than Group II or III (p < 0.05). Group II showed a longer recovery period than Group III (p < 0.05). Postoperative routine CT was useful for predicting anastomotic leak using specific findings, and for predicting length of recovery period. (orig.)

  9. Thermal animal detection system (TADS)

    Energy Technology Data Exchange (ETDEWEB)

    Desholm, M.

    2003-03-01

    This report presents data from equipment tests and software development for the Thermal Animal Detection System (TADS) development project: 'Development of a method for estimating collision frequency between migrating birds and offshore wind turbines'. The technical tests were performed to investigate the performance of remote controlling, video file compression tool and physical stress of the thermal camera when operating outdoors and under the real time vibration conditions at a 2 MW turbine. Furthermore, experimental tests on birds were performed to describe the decreasing detectability with distance on free flying birds, the performance of the thermal camera during poor visibility, and finally, the performance of the thermal sensor software developed for securing high -quality data. In general, it can be concluded that the thermal camera and its related hardware and software, the TADS, are capable of recording migrating birds approaching the rotating blades of a turbine, even under conditions with poor visibility. If the TADS is used in a vertical viewing scenario it would comply with the requirements for a setup used for estimating the avian collision frequency at offshore wind turbines. (au)

  10. Distributed Impact Detection System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Automated impact detection and characterization on manned spacecraft has been an elusive goal due to the transitory nature of the detectable high-frequency signals....

  11. 40 CFR 63.148 - Leak inspection provisions.

    Science.gov (United States)

    2010-07-01

    ... inspections for visible, audible, or olfactory indications of leaks. (2) If the vapor collection system or... provisions. (a) Except as provided in paragraph (k) of this section, for each vapor collection system, closed-vent system, fixed roof, cover, or enclosure required to comply with this section, the owner...

  12. Leak signature space: an original representation for robust leak location in water distribution networks

    OpenAIRE

    Casillas, Myrna V.; Garza-Castañón, Luis E.; Vicenç Puig; Adriana Vargas-Martinez

    2015-01-01

    In this paper, an original model-based scheme for leak location using pressure sensors in water distribution networks is introduced. The proposed approach is based on a new representation called the Leak Signature Space (LSS) that associates a specific signature to each leak location being minimally affected by leak magnitude. The LSS considers a linear model approximation of the relation between pressure residuals and leaks that is projected onto a selected hyperplane. This new approach allo...

  13. Leaking electricity in domestic appliances

    Energy Technology Data Exchange (ETDEWEB)

    Meier, Alan; Rosen, Karen

    1999-05-01

    Many types of home electronic equipment draw electric power when switched off or not performing their principal functions. Standby power use (or ''leaking electricity'') for most appliances ranges from 1 - 20 watts. Even though standby use of each device is small, the combined standby power use of all appliances in a home can easily exceed 50 watts. Leaking electricity is already responsible for 5 to 10 percent of residential electricity use in the United States and over 10 percent in Japan. An increasing number of white goods also have standby power requirements. There is a growing international effort to limit standby power to around one watt per device. New and existing technologies are available to meet this target at little or no extra cost.

  14. Development of systems for detection, early warning, and control of pipeline leakage in drinking water distribution: A case study

    Institute of Scientific and Technical Information of China (English)

    Weifeng Li; Wencui Ling; Suoxiang Liu; Jing Zhao; Ruiping Liu; Qiuwen Chen; Zhimin Qiang; Jiuhui Qu

    2011-01-01

    Water leakage in drinking water distribution systems is a serious problem for many cities and a huge challenge for water utilities.An integrated system for the detection,early warning,and control of pipeline leakage has been developed and successfully used to manage the pipeline networks in selected areas of Beijing.A method based on the geographic information system has been proposed to quickly and automatically optimize the layout of the instruments which detect leaks.Methods are also proposed to estimate the probability of each pipe segment leaking (on the basis of historic leakage data),and to assist in locating the leakage points (based on leakage signals).The district metering area (DMA) strategy is used.Guidelines and a flowchart for establishing a DMA to manage the large-scale looped networks in Beijing are proposed.These different functions have been implemented into a central software system to simplify the day-to-day use of the system.In 2007 the system detected 102 non-obvious leakages (i.e.,14.2% of the total detected in Beijing) in the selected areas,which was estimated to save a total volume of 2,385,000 m3 of water.These results indicate the feasibility,efficiency and wider applicability of this system.

  15. Investigation of dependence of BN-600 reactor sector fuel cladding leak detection system responses on the operation parameters

    Directory of Open Access Journals (Sweden)

    O.I. Albutova

    2015-12-01

    Implemented studies of dependence of background on the reactor operational parameters are of practical importance and are original scientifically - similar types of research have not been done previously. Upon completion of testing and validation of the developed model using extended volume of reactor operation data the issue will be addressed of the implementation of the methodology within the composition of the SFCLDS of BN-600 and BN-800 reactors.

  16. Detection of Abrupt Changes in Dynamic Systems,

    Science.gov (United States)

    1984-01-01

    the detection of abrupt chnages in dynamic systems. These efforts have been motivated by a wide variety of applications includinq the detection of...34Failure Detection in Dynimic Systems," AGARD Lecture Series No. 109 on Fault Tolerance Design and Redundancy Management Technqiues, Athens, Rome, and

  17. 基于RBF神经网络的天然气管道泄漏检测技术研究%The natural gas pipeline leak detection technology based on RBF neural network research

    Institute of Scientific and Technical Information of China (English)

    高丙坤; 郑仁谦; 尹淑欣; 张莉; 岳武峰

    2016-01-01

    为了正确判断管道是否发生泄漏,本文采用混合学习方法对网络进行训练学习。通过将管道运行参数作为神经网络的输入,管道运行状态作为神经网络的输出,实现两者的非线性映射,以此来判断输入信号是否为泄漏信号,并选用K-means聚类方法和递推最小二乘法来确定网络参数。通过用天然气管道运行的实测数据对RBF神经网络进行了训练和测试,得到结果误差在可接受的范围内,从而证明RBF神经网络的方法可用于天然气管道泄漏检测的研究。%In order to correctly determine whether pipeline leakage occurs, this paper adopts a hybrid learning method for network training. We set the pipeline operation parameters as the input of neural network and running status of the pipe as the neural network output, realizing the two nonlinear mapping, in order to determine whether the input signal is leakage signal , and select K-means clustering method and the recursive least square method to determine the network parameters. With the measurements of the gas pipeline operation on training and testing the RBF neural network, we get the results in an acceptable error range, which prove that the method of RBF neural network can be used for natural gas pipeline leak detection.

  18. Intelligent Detection System framework using Mobile agents

    CERN Document Server

    Jaisankar, N; Swamy, K Durai

    2010-01-01

    An intrusion detection system framework using mobile agents is a layered framework mechanism designed to support heterogeneous network environments to identify intruders at its best. Traditional computer misuse detection techniques can identify known attacks efficiently, but perform very poorly in other cases. Anomaly detection has the potential to detect unknown attacks; however, it is a very challenging task since its aim is to detect unknown attacks without any priori knowledge about specific intrusions. This technology is still at its early stage. The objective of this paper is that the system can detect anomalous user activity. Existing research in this area focuses either on user activity or on program operation but not on both simultaneously. In this paper, an attempt to look at both concurrently is presented. Based on an intrusion detection framework [1], a novel user anomaly detection system has been implemented and conducted several intrusion detection experiments in a simulated environment by analy...

  19. Classification and Importance of Intrusion Detection System

    Directory of Open Access Journals (Sweden)

    Rajasekaran K

    2012-08-01

    Full Text Available An intrusion detection system (IDS is a device or software application that monitors network or system activities for malicious activities or policy violations and produces reports to a Management Station. Some systems may attempt to stop an intrusion attempt but this is neither required nor expected of a monitoring system. Due to a growing number of intrusion events and also because the Internet and local networks have become so ubiquitous, organizations are increasingly implementing various systems that monitor IT security breaches. This includes an overview of the classification of intrusion detection systems and introduces the reader to some fundamental concepts of IDS methodology: audit trail analysis and on-the-fly processing as well as anomaly detection and signature detection approaches. This research paper discusses the primary intrusion detection techniques and the classification of intrusion Detection system.

  20. Research of Vision Detection System on PCB

    Institute of Scientific and Technical Information of China (English)

    CHENG Songlin; ZHOU Zude; HU Wenjuan

    2006-01-01

    Machine vision is applied in defect detection system on PCB. The whole system structure and the principle of vision detection are introduced, while the detection method including image processing, detection and recognition algorithms are detailed. The simulation results demonstrate that through this method, four types of defects including short circuit, open circuit, protuberance and concavity on PCB circuit can be effectively inspected, located and recognized.

  1. Design and implementation of self-protection agent for network-based intrusion detection system

    Institute of Scientific and Technical Information of China (English)

    朱树人; 李伟琴

    2003-01-01

    Static secure techniques, such as firewall, hierarchy filtering, distributed disposing,layer management, autonomy agent, secure communication, were introduced in distributed intrusion detection. The self-protection agents were designed, which have the distributed architecture,cooperate with the agents in intrusion detection in a loose-coupled manner, protect the security of intrusion detection system, and respond to the intrusion actively. A prototype self-protection agent was implemented by using the packet filter in operation system kernel. The results show that all the hosts with the part of network-based intrusion detection system and the whole intrusion detection system are invisible from the outside and network scanning, and cannot apperceive the existence of network-based intrusion detection system. The communication between every part is secure. In the low layer, the packet streams are controlled to avoid the buffer leaks exist ing in some system service process and back-door programs, so as to prevent users from misusing and vicious attack like Trojan Horse effectively.

  2. Leak Isolation in Pressurized Pipelines using an Interpolation Function to approximate the Fitting Losses

    Science.gov (United States)

    Badillo-Olvera, A.; Begovich, O.; Peréz-González, A.

    2017-01-01

    The present paper is motivated by the purpose of detection and isolation of a single leak considering the Fault Model Approach (FMA) focused on pipelines with changes in their geometry. These changes generate a different pressure drop that those produced by the friction, this phenomenon is a common scenario in real pipeline systems. The problem arises, since the dynamical model of the fluid in a pipeline only considers straight geometries without fittings. In order to address this situation, several papers work with a virtual model of a pipeline that generates a equivalent straight length, thus, friction produced by the fittings is taking into account. However, when this method is applied, the leak is isolated in a virtual length, which for practical reasons does not represent a complete solution. This research proposes as a solution to the problem of leak isolation in a virtual length, the use of a polynomial interpolation function in order to approximate the conversion of the virtual position to a real-coordinates value. Experimental results in a real prototype are shown, concluding that the proposed methodology has a good performance.

  3. Fusion of Heterogeneous Intrusion Detection Systems for Network Attack Detection

    Directory of Open Access Journals (Sweden)

    Jayakumar Kaliappan

    2015-01-01

    Full Text Available An intrusion detection system (IDS helps to identify different types of attacks in general, and the detection rate will be higher for some specific category of attacks. This paper is designed on the idea that each IDS is efficient in detecting a specific type of attack. In proposed Multiple IDS Unit (MIU, there are five IDS units, and each IDS follows a unique algorithm to detect attacks. The feature selection is done with the help of genetic algorithm. The selected features of the input traffic are passed on to the MIU for processing. The decision from each IDS is termed as local decision. The fusion unit inside the MIU processes all the local decisions with the help of majority voting rule and makes the final decision. The proposed system shows a very good improvement in detection rate and reduces the false alarm rate.

  4. DETECCIÓN DE PÉRDIDAS EN TUBERÍAS DE AGUA: PROPUESTA BASADA EN UN BANCO DE FILTROS LEAK DETECTION IN WATER PIPELINES: PROPOSAL BASED ON A BANK OF FILTERS

    Directory of Open Access Journals (Sweden)

    Lucía Castro Burgos

    2009-12-01

    Full Text Available Actualmente la detección de pérdidas (DP en tuberías de agua es un área de investigación activa, y con un creciente interés, debido a la importancia del transporte seguro del vital elemento. Este trabajo considera el problema de DP en tuberías de agua por medio de redundancia analítica, basada en un modelo matemático y utilizando técnicas de estimación de estados, teniendo por objetivo principal estudiar, proponer, implementar y aplicar algoritmos eficientes que permitan abordar de manera general el problema de DP. Para lograr esto se propone y evalúa un banco de filtros, implementados con filtros de Kalman (FK y filtros de partículas (FP. Con esto se busca contribuir conceptualmente a la formulación del problema de DP, de manera modular, permitiendo que en un estudio futuro otras técnicas puedan ser utilizadas para resolver el problema. Además, obtener algoritmos eficientes y confiables, basados en un estimador de estados capaces de responder a requerimientos industriales, tales como: entregar, a partir de medidas de entrada y salida disponibles, una estimación fiable del estado del proceso, esto con independencia de la dinámica lineal o no lineal, asimismo, ser de fácil manejo y fácil configuración. La simulación computacional y los resultados experimentales muestran la efectividad de combinar FP con FK, para el caso básico de dos pérdidas secuenciales en una tubería, presentando ventajas de rápida convergencia y reducción del error de estimación, factores importantes en el problema de DP en ductos hídricos.Currently leak detection (LD in water pipelines is an active area of research that is attracting increasing interest due to the importance of the safe transport of this vital resource. This work considers the problem of LD in water pipes by means of analytical redundancy, based on a mathematical model and using state estimation techniques. The main aim of this work is to research, propose, implement and apply

  5. Imaging with the leak microstructures: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Baiocchi, C.; Balbinot, G; Battistella, A.; Galeazzi, G.; Lombardi, F.S.; Lombardi, M. E-mail: mariano.lombardi@lnl.infn.it; Prete, G.; Simon, A

    2004-02-01

    We report on some images obtained with the Leak Microstructures (LM), which are elements for the detection of gas ionizing particles based on needle-point anodes. X-ray images of a mask with seven holes, 300 {mu}m in diameter and 100 {mu}m separated, drilled on a tantalum sheet were obtained with a very good spatial resolution. Varying the potential to the drifting electrode we put in evidence the possibility to perform a 'zoom' of the image. X-ray images of a tantalum sheet of about 20x20 mm{sup 2} were obtained using a matrix of 9x9 LMs read by only 6 electronic chains (6 ADCs)

  6. Method for HEPA filter leak scanning with differentiating aerosol detector

    Energy Technology Data Exchange (ETDEWEB)

    Kovach, B.J.; Banks, E.M.; Wikoff, W.O. [NUCON International, Inc., Columbus, OH (United States)

    1997-08-01

    While scanning HEPA filters for leaks with {open_quotes}Off the Shelf{close_quote} aerosol detection equipment, the operator`s scanning speed is limited by the time constant and threshold sensitivity of the detector. This is based on detection of the aerosol density, where the maximum signal is achieved when the scanning probe resides over the pinhole longer than several detector time-constants. Since the differential value of the changing signal can be determined by observing only the first small fraction of the rising signal, using a differentiating amplifier will speed up the locating process. The other advantage of differentiation is that slow signal drift or zero offset will not interfere with the process of locating the leak, since they are not detected. A scanning hand-probe attachable to any NUCON{reg_sign} Aerosol Detector displaying the combination of both aerosol density and differentiated signal was designed. 3 refs., 1 fig.

  7. Determining Methane Leak Locations and Rates with a Wireless Network Composed of Low-Cost, Printed Sensors

    Science.gov (United States)

    Smith, C. J.; Kim, B.; Zhang, Y.; Ng, T. N.; Beck, V.; Ganguli, A.; Saha, B.; Daniel, G.; Lee, J.; Whiting, G.; Meyyappan, M.; Schwartz, D. E.

    2015-12-01

    We will present our progress on the development of a wireless sensor network that will determine the source and rate of detected methane leaks. The targeted leak detection threshold is 2 g/min with a rate estimation error of 20% and localization error of 1 m within an outdoor area of 100 m2. The network itself is composed of low-cost, high-performance sensor nodes based on printed nanomaterials with expected sensitivity below 1 ppmv methane. High sensitivity to methane is achieved by modifying high surface-area-to-volume-ratio single-walled carbon nanotubes (SWNTs) with materials that adsorb methane molecules. Because the modified SWNTs are not perfectly selective to methane, the sensor nodes contain arrays of variously-modified SWNTs to build diversity of response towards gases with adsorption affinity. Methane selectivity is achieved through advanced pattern-matching algorithms of the array's ensemble response. The system is low power and designed to operate for a year on a single small battery. The SWNT sensing elements consume only microwatts. The largest power consumer is the wireless communication, which provides robust, real-time measurement data. Methane leak localization and rate estimation will be performed by machine-learning algorithms built with the aid of computational fluid dynamics simulations of gas plume formation. This sensor system can be broadly applied at gas wells, distribution systems, refineries, and other downstream facilities. It also can be utilized for industrial and residential safety applications, and adapted to other gases and gas combinations.

  8. Technoeconomic analysis of renewable hydrogen production, storage, and detection systems

    Energy Technology Data Exchange (ETDEWEB)

    Mann, M.K.; Spath, P.L.; Kadam, K. [National Renewable Energy Lab., Golden, CO (United States)

    1996-10-01

    Technical and economic feasibility studies of different degrees of completeness and detail have been performed on several projects being funded by the Department of Energy`s Hydrogen Program. Work this year focused on projects at the National Renewable Energy Laboratory, although analyses of projects at other institutions are underway or planned. Highly detailed analyses were completed on a fiber optic hydrogen leak detector and a process to produce hydrogen from biomass via pyrolysis followed by steam reforming of the pyrolysis oil. Less detailed economic assessments of solar and biologically-based hydrogen production processes have been performed and focused on the steps that need to be taken to improve the competitive position of these technologies. Sensitivity analyses were conducted on all analyses to reveal the degree to which the cost results are affected by market changes and technological advances. For hydrogen storage by carbon nanotubes, a survey of the competing storage technologies was made in order to set a baseline for cost goals. A determination of the likelihood of commercialization was made for nearly all systems examined. Hydrogen from biomass via pyrolysis and steam reforming was found to have significant economic potential if a coproduct option could be co-commercialized. Photoelectrochemical hydrogen production may have economic potential, but only if low-cost cells can be modified to split water and to avoid surface oxidation. The use of bacteria to convert the carbon monoxide in biomass syngas to hydrogen was found to be slightly more expensive than the high end of currently commercial hydrogen, although there are significant opportunities to reduce costs. Finally, the cost of installing a fiber-optic chemochromic hydrogen detection system in passenger vehicles was found to be very low and competitive with alternative sensor systems.

  9. Gravitational Waves III: Detecting Systems

    OpenAIRE

    Cattani, M.

    2010-01-01

    In a recent paper we have deduced the basic equations that predict the emission of gravitational waves (GW) according to the Einstein gravitation theory. In a subsequent paper these equations have been used to calculate the luminosities and the amplitudes of the waves generated by binary stars, pulsations of neutron stars, wobbling of deformed neutron stars, oscillating quadrupoles, rotating bars and collapsing and bouncing cores of supernovas. We show here how the GW could be detected in our...

  10. The Anti-leak Password Management System based on Bluetooth and NFC%基于蓝牙和NFC的防泄露密码使用管理系统

    Institute of Scientific and Technical Information of China (English)

    严志涛; 徐梦霖; 吴潇岛; 赵辉

    2013-01-01

    With the widespread use of passwords, users have to remember a large number of complicated passwords. It is more and more dififcult to remember and enter them. This paper proposes a design of the anti-leak password management system based on Bluetooth and NFC in order to help users remember and enter numerous passwords. This system uses NFC authentication, key distribution mechanism similar to KDC (Key Distribution Center), loss report mechanism and so on to guarantee password security. The test results indicate that this system can help users remember and enter a large number of passwords effectively, and the security mechanism such as loss report mechanism can protect passwords from being leaked.%随着密码使用越来越广泛,用户需要记忆大量复杂的密码来保证安全,密码的记忆和输入变得越来越困难。为此,文章提出了一种基于蓝牙NFC的防泄露密码使用管理系统的设计,帮助用户记忆大量密码以及方便输入,并采用NFC(近场通讯)身份验证、类似于KDC(密钥分配中心)的密钥分配机制、挂失机制等安全机制来保证用户的密码安全。测试结果表明该系统能有效地帮助用户记忆大量密码以及快捷地进行密码的输入,并用挂失等安全机制有效地保证用户的密码不被泄露。

  11. Validation of Test Methods for Air Leak Rate Verification of Spaceflight Hardware

    Science.gov (United States)

    Oravec, Heather Ann; Daniels, Christopher C.; Mather, Janice L.

    2017-01-01

    As deep space exploration continues to be the goal of NASAs human spaceflight program, verification of the performance of spaceflight hardware becomes increasingly critical. Suitable test methods for verifying the leak rate of sealing systems are identified in program qualification testing requirements. One acceptable method for verifying the air leak rate of gas pressure seals is the tracer gas leak detector method. In this method, a tracer gas (commonly helium) leaks past the test seal and is transported to the leak detector where the leak rate is quantified. To predict the air leak rate, a conversion factor of helium-to-air is applied depending on the magnitude of the helium flow rate. The conversion factor is based on either the molecular mass ratio or the ratio of the dynamic viscosities. The current work was aimed at validating this approach for permeation-level leak rates using a series of tests with a silicone elastomer O-ring. An established pressure decay method with constant differential pressure was used to evaluate both the air and helium leak rates of the O-ring under similar temperature and pressure conditions. The results from the pressure decay tests showed, for the elastomer O-ring, that neither the molecular flow nor the viscous flow helium-to-air conversion factors were applicable. Leak rate tests were also performed using nitrogen and argon as the test gas. Molecular mass and viscosity based helium-to-test gas conversion factors were applied, but did not correctly predict the measured leak rates of either gas. To further this study, the effect of pressure boundary conditions was investigated. Often, pressure decay leak rate tests are performed at a differential pressure of 101.3 kPa with atmospheric pressure on the downstream side of the test seal. In space applications, the differential pressure is similar, but with vacuum as the downstream pressure. The same O-ring was tested at four unique differential pressures ranging from 34.5 to 137.9 k

  12. Intrusion Detection Approach Using Connectionist Expert System

    Institute of Scientific and Technical Information of China (English)

    MA Rui; LIU Yu-shu; DU Yan-hui

    2005-01-01

    In order to improve the detection efficiency of rule-based expert systems, an intrusion detection approach using connectionist expert system is proposed. The approach converts the AND/OR nodes into the corresponding neurons, adopts the three-layered feed forward network with full interconnection between layers,translates the feature values into the continuous values belong to the interval [0, 1 ], shows the confidence degree about intrusion detection rules using the weight values of the neural networks and makes uncertain inference with sigmoid function. Compared with the rule-based expert system, the neural network expert system improves the inference efficiency.

  13. Development of the environmental neutron detection system

    CERN Document Server

    Kume, K

    2002-01-01

    Environmental neutron detection system was proposed and developed. The main goal of this system was set to detect fast and thermal neutrons with the identical detectors setup without degraders. This system consists of a sup 1 sup 0 B doped liquid scintillator for n detection and CsI scintillators for simultaneous gamma emission from sup 1 sup 0 B doped in the liquid scintillator after the n capture reaction. The first setup was optimized for the thermal n detection, while the second setup was for the fast n detection. It was shown that the thermal n flux was obtained in the first setup by using the method of the gamma coincidence method with the help of the Monte Carlo calculation. The second setup was designed to improve the detection efficiency for the fast n, and was shown qualitatively that both the pulse shape discrimination and the coincidence methods are efficient. There will be more improvements, particularly for the quantitative discussion.

  14. Deep Water Munitions Detection System

    Science.gov (United States)

    2010-03-01

    signal to noise ratios which are shown in Figure 5. The signal to noise was calculated using an algorithm that is part of the Oasis montaj software...using an algorithm that is part of the Oasis montaj software suite. The signal strength of an anomaly is calculated as the sum of the squares of...Process Software extension for Geosoft Oasis Montaj , version 6.4, May 28, 2007 8. DeProspo,D. and R. DiMarco, “Automatic Detection and

  15. Anomaly Detection for Complex Systems

    Data.gov (United States)

    National Aeronautics and Space Administration — In performance maintenance in large, complex systems, sensor information from sub-components tends to be readily available, and can be used to make predictions about...

  16. Strength and leak testing of plasma activated bonded interfaces

    DEFF Research Database (Denmark)

    Visser, M.M.; Weichel, Steen; Reus, Roger De

    2002-01-01

    Bond strength and hermeticity of plasma activated bonded (PAB) Si-Si interfaces are reported. Bonding of 100 mm Si(1 0 0) wafers was performed. An average bond strength of 9.0+/-3.9 MPa was achieved without performing any annealing steps. Cavities bonded in vacuum were found to be hermetic based...... on detection of changes in membrane deflections. The detection limit for leak was 8E-13 mbar l/s. For comparison, strength and leak tests were also performed with regular fusion bonded wafers annealed at 1100 degreesC. The PAB was found to withstand post-processing steps such as RCA cleaning, 24 h in de......-ionised water (DIW), 24 h in 2.5% HF, 24 h in acetone and 60 s in a resist developer. By analysing the thin silicon oxide present on the surfaces to be bonded with optical methods, the influence of pre-cleaning and activation process parameters was investigated....

  17. Design of Secure Distributed Intrusion Detection Systems

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Intrusion Detection System (IDS) have received a great deal of attention because of their excellent ability of preventing network incidents. Recently, many efficient approaches have been proposed to improve detection ability of IDS. While the self-protection ability of IDS is relatively worse and easy to be exploited by attackers, this paper gives a scheme of Securely Distributed Intrusion Detection System (SDIDS). This system adopts special measurements to enforce the security of IDS components. A new secure mechanism combining role-based access control and attribute certificate is used to resist attack to communication.

  18. Embedded Systems - Missile Detection/Interception

    Directory of Open Access Journals (Sweden)

    Luis Cintron

    2010-01-01

    Full Text Available Missile defense systems are often related to major military resources aimed at shielding a specific region from incoming attacks. They are intended to detect, track, intercept, and destruct incoming enemy missiles. These systems vary in cost, efficiency, dependability, and technology. In present times, the possession of these types of systems is associated with large capacity military countries. Demonstrated here are the mathematical techniques behind missile systems which calculate trajectories of incoming missiles and potential intercept positions after initial missile detection. This procedure involved the use of vector-valued functions, systems of equations, and knowledge of projectile motion concepts.

  19. Intermediate-Scale Laboratory Experiments of Subsurface Flow and Transport Resulting from Tank Leaks

    Energy Technology Data Exchange (ETDEWEB)

    Oostrom, Martinus; Wietsma, Thomas W.

    2014-09-30

    Washington River Protection Solutions contracted with Pacific Northwest National Laboratory to conduct laboratory experiments and supporting numerical simulations to improve the understanding of water flow and contaminant transport in the subsurface between waste tanks and ancillary facilities at Waste Management Area C. The work scope included two separate sets of experiments: •Small flow cell experiments to investigate the occurrence of potential unstable fingering resulting from leaks and the limitations of the STOMP (Subsurface Transport Over Multiple Phases) simulator to predict flow patterns and solute transport behavior under these conditions. Unstable infiltration may, under certain conditions, create vertically elongated fingers potentially transporting contaminants rapidly through the unsaturated zone to groundwater. The types of leak that may create deeply penetrating fingers include slow release, long duration leaks in relatively permeable porous media. Such leaks may have occurred below waste tanks at the Hanford Site. •Large flow experiments to investigate the behavior of two types of tank leaks in a simple layered system mimicking the Waste Management Area C. The investigated leaks include a relatively large leak with a short duration from a tank and a long duration leak with a relatively small leakage rate from a cascade line.

  20. Contribution of mitochondrial proton leak to skeletal muscle respiration and to standard metabolic rate.

    Science.gov (United States)

    Rolfe, D F; Brand, M D

    1996-10-01

    We have tested the hypothesis that the leak of protons across the mitochondrial inner membrane (proton leak) is a significant contributor to standard metabolic rate (SMR). We found that proton leak accounts for around one-half of the resting respiration rate of perfused rat skeletal muscle. Proton leak is known to make a significant (26%) contribution to the resting respiration rate of isolated rat hepatocytes (M. D. Brand, L.-F. Chien, E. K. Ainscow, D. F. S. Rolfe, and R. K. Porter. Biochim. Biophys. Acta 1187: 132-139, 1994). If the importance of proton leak in these isolated and perfused systems is similar to its importance in vivo, then using literature values for the contribution of liver and skeletal muscle to SMR, we can calculate that proton leak in liver and skeletal muscle alone accounts for 11-26% (mean 20%) of the SMR of the rat. If proton leak activity in the other tissues of the rat is similar to that in liver cells, then the contribution of proton leak to rat SMR would be 16-31% (mean 25%).

  1. Helium-neon lasers for remote measurements of natural gas leaks

    Science.gov (United States)

    1983-09-01

    A Differential Absorption Lidar (DIAL) system that at a distance of 15 meters can remotely sense natura gas (methane) leaks was developed. The system uses two helium-neon lasers (each emitting a different wavelength), a receiver, and an indium antimonide (InSb) photodetector cooled to 77 K. It is demonstrated the system can defect methane leaks both from an underground gas distribution system, and from sanitary landfills.

  2. Research of Telescope Space Particle Detection System

    Institute of Scientific and Technical Information of China (English)

    CHENG; Yu-min; LAN; Xiao-fei

    2015-01-01

    To meet the needs of space environment detection of high-energy particles,we developed a prototype of space electron-proton flux detector,used in measurements of electronics and proton flux inside and outside the spacecraft.This detection system has the following advantages:

  3. Statistical fault detection in photovoltaic systems

    KAUST Repository

    Garoudja, Elyes

    2017-05-08

    Faults in photovoltaic (PV) systems, which can result in energy loss, system shutdown or even serious safety breaches, are often difficult to avoid. Fault detection in such systems is imperative to improve their reliability, productivity, safety and efficiency. Here, an innovative model-based fault-detection approach for early detection of shading of PV modules and faults on the direct current (DC) side of PV systems is proposed. This approach combines the flexibility, and simplicity of a one-diode model with the extended capacity of an exponentially weighted moving average (EWMA) control chart to detect incipient changes in a PV system. The one-diode model, which is easily calibrated due to its limited calibration parameters, is used to predict the healthy PV array\\'s maximum power coordinates of current, voltage and power using measured temperatures and irradiances. Residuals, which capture the difference between the measurements and the predictions of the one-diode model, are generated and used as fault indicators. Then, the EWMA monitoring chart is applied on the uncorrelated residuals obtained from the one-diode model to detect and identify the type of fault. Actual data from the grid-connected PV system installed at the Renewable Energy Development Center, Algeria, are used to assess the performance of the proposed approach. Results show that the proposed approach successfully monitors the DC side of PV systems and detects temporary shading.

  4. IMPROVING CAUSE DETECTION SYSTEMS WITH ACTIVE LEARNING

    Data.gov (United States)

    National Aeronautics and Space Administration — IMPROVING CAUSE DETECTION SYSTEMS WITH ACTIVE LEARNING ISAAC PERSING AND VINCENT NG Abstract. Active learning has been successfully applied to many natural language...

  5. NQR Stimulation Technique for Explosives Detection System

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    A method of customization stimulation signal based on direct digital frequency synthesis (DDS) for Nuclear Quadrapole Resonance Explosives Detection System is presented. DDS has many advantages, such as high frequency resolution, high convert speed,

  6. Detection and intelligent systems for homeland security

    CERN Document Server

    Voeller, John G

    2014-01-01

    Detection and Intelligent Systems for Homeland Security features articles from the Wiley Handbook of Science and Technology for Homeland Security covering advanced technology for image and video interpretation systems used for surveillance, which help in solving such problems as identifying faces from live streaming or stored videos. Biometrics for human identification, including eye retinas and irises, and facial patterns are also presented. The book then provides information on sensors for detection of explosive and radioactive materials and methods for sensing chemical

  7. Heartbeat detection system using piezoelectric transducer

    Science.gov (United States)

    Hamonangan, Yosua; Purnamaningsih, Wigajatri

    2017-02-01

    This paper presents a simple piezoelectric based heartbeat detection system. The signal produced by the piezoelectric will undergo signal conditioning and then converted into digital data by Arduino Nano. Using serial communication, the data will be sent to a computer for display and further analysis. The detection of heartbeat is carried out on three locations; wrist, chest, and diaphragm. From the measurement results, it is shown that the system work best when the piezoelectric is placed on wrist.

  8. New Detection System for Heavy Element Research

    CERN Document Server

    Tsyganov, Y S; Voinov, A A; Shumeyko, M V

    2015-01-01

    New detection system design for heavy element research with 48Ca projectile has been reported. This system is based on application of 32 position sensitive strip PIPS detector and low pressure pentane filled TOF detector application in 48Ca induced nuclear reactions. To suppress beam associated background products new version of real time method of active correlations has been applied. Examples of applications in 249Bk+48Ca and 243Am+48Ca reactions are presented. The system development to operate together with the digital ORNL detection system to provide a quick search for recoil to alpha correlation chains has been discussed too.

  9. Leaks in nuclear grade high efficiency aerosol filters

    Energy Technology Data Exchange (ETDEWEB)

    Scripsick, Ronald Clyde [Univ. of California, Davis, CA (United States)

    1994-07-01

    Nuclear grade high efficiency aerosol filters, also known as high efficiency particulate air (HEPA) filters, are commonly used in air cleaning systems for removal of hazardous aerosols. Performance of the filter units is important in assuring health and environmental protection. The filter units are constructed from pleated packs of fiberglass filter media sealed into rigid frames. Results of previous studies on such filter units indicate that their performance may not be completely predicted by ideal performance of the fibrous filter media. In this study, departure from ideal performance is linked to leaks existing in filter units and overall filter unit performance is derived from independent performance of the individual filter unit components. The performance of 14 nuclear grade HEPA filter units (size 1, 25 cfm) with plywood frames was evaluated with a test system that permitted independent determination of penetration as a function of particle size for the whole filter unit, the filter unit frame, and the filter media pack. Tests were performed using a polydisperse aerosol of di-2-ethylhexyl phthalate with a count median diameter of 0.2 {mu}m and geometric standard deviation of 1.6. Flow rate and differential pressure were controlled from 1% to 100% of design values. Particle counts were made upstream and downstream of the filter unit with an optical particle counter (OPC). The OPC provided count information in 28 size channels over the particle diameter range from 0.1 to 0.7 μm. Results provide evidence for a two component leak model of filler unit performance with: (1) external leaks through filter unit frames, and (2) internal leaks through defects in the media and through the seal between the media pack and frame. For the filter units evaluated, these leaks dominate overall filter unit performance over much of the flow rate and particle size ranges tested.

  10. Intrusion Detection amp Prevention Systems - Sourcefire Snort

    Directory of Open Access Journals (Sweden)

    Rajesh Vuppala

    2015-08-01

    Full Text Available Information security is a challenging issue for all business organizations today amidst increasing cyber threats. While there are many alternative intrusion detection amp prevention systems available to choose from selecting the best solution to implement to detect amp prevent cyber-attacks is a difficult task. The best solution is of the one that gets the best reviews and suits the organizations needs amp budget. In this review paper we summarize various classes of intrusion detection and prevention systems compare features of alternative solutions and make recommendation for implementation of one as the best solution for business organization in Fiji.

  11. Cluster based Intrusion Detection System for Manets

    Directory of Open Access Journals (Sweden)

    Nisha Dang

    2012-07-01

    Full Text Available Manets are the ad hoc networks that are build on demand or instantly when some mobile nodes come in the mobility range of each other and decide to cooperate for data transfer and communication. Therefore there is no defined topology for Manets. They communicate in dynamic topology which continuously changes as nodes are not stable. Due to this lack of infrastructure and distributed nature they are more vulnerable for attacks and provide a good scope to malicious users to become part of the network. To prevent the security of mobile ad hoc networks many security measures are designed such as encryption algorithms, firewalls etc. But still there is some scope of malicious actions. So, Intrusion detection systems are proposed to detect any intruder in the network and its malicious activities. Cluster based intrusion detection system is also designed to restrict the intruders activities in clusters of mobile nodes. In clusters each node run some intrusion detection code to detect local as well as global intrusion. In this paper we have taken insight of intrusion detection systems and different attacks on Manet security. Then we proposed how overhead involved in cluster based intrusion detection system can be reduced.

  12. Automatic leak location in a pipe; Localizador automatico de fugas en un ducto

    Energy Technology Data Exchange (ETDEWEB)

    Carrera Mendez, Rolando; Verde Rodarte, Cristina [Universidad Nacional Autonoma de Mexico (Mexico)

    2001-06-01

    A real time method for detecting and locating leaks in pipes is analysed. By monitoring pressure gradients of a pipe in a steady state operation, expressions that indicate the existence of a leak and its location are derived. For small leaks it is possible to deduce alternative expressions based on in- and outflow deviations from their normal values. These deviations are estimated by means of a nonlinear dynamic flow observer. It is an easy task to carry out this system and the detection and location algorithm require low resource. As a result of this analysis it was found that the identifier is very sensitive to variations of the D'Arcy-Weissbach friction. [Spanish] Se describe y analiza un metodo que permite detectar y ubicar fugas de liquidos en un ducto sin tomas laterales en tiempo real. A partir de una operacion en estado permanente y del monitoreo de los gradientes de presion en los extremos de la tuberia, se derivan expresiones que permiten detectar la existencia de una fuga y su localizacion. Tambien se muestra que para fugas pequenas se pueden obtener expresiones alternativas para la deteccion y localizacion, basadas en las desviaciones de los flujos con respecto a sus valores nominales. Dicha desviacion se estima con un observador dinamico no lineal del comportamiento de flujo. La realizacion es de facil implantacion y el algoritmo se deteccion y localizacion requiere de pocos recursos de computacion. Del analisis presentado se desprende que el localizador es muy sensible a las variaciones en la estimacion de la friccion de D'Arcy-Weissbach del ducto.

  13. Successful Endoscopic Therapy of Traumatic Bile Leaks

    Directory of Open Access Journals (Sweden)

    Matthew P. Spinn

    2013-02-01

    Full Text Available Traumatic bile leaks often result in high morbidity and prolonged hospital stay that requires multimodality management. Data on endoscopic management of traumatic bile leaks are scarce. Our study objective was to evaluate the efficacy of the endoscopic management of a traumatic bile leak. We performed a retrospective case review of patients who were referred for endoscopic retrograde cholangiopancreatography (ERCP after traumatic bile duct injury secondary to blunt (motor vehicle accident or penetrating (gunshot trauma for management of bile leaks at our tertiary academic referral center. Fourteen patients underwent ERCP for the management of a traumatic bile leak over a 5-year period. The etiology included blunt trauma from motor vehicle accident in 8 patients, motorcycle accident in 3 patients and penetrating injury from a gunshot wound in 3 patients. Liver injuries were grade III in 1 patient, grade IV in 10 patients, and grade V in 3 patients. All patients were treated by biliary stent placement, and the outcome was successful in 14 of 14 cases (100%. The mean duration of follow-up was 85.6 days (range 54-175 days. There were no ERCP-related complications. In our case review, endoscopic management with endobiliary stent placement was found to be successful and resulted in resolution of the bile leak in all 14 patients. Based on our study results, ERCP should be considered as first-line therapy in the management of traumatic bile leaks.

  14. Leveraging Social Norms to Improve Leak Resolution Outcomes Across Meter Classes:

    Science.gov (United States)

    Holleran, W.

    2016-12-01

    Over the past decade, utilities, governments, businesses, and nonprofits have come to realize that more than just financial considerations and information drive behavior. Social and psychological factors also play a significant role in shaping consumers' decisions and behaviors around resource use. Stakeholders have consequently turned their interest to behavioral science, a multidisciplinary field that draws from psychology, sociology, public health, and behavioral economics to explain the complex mechanisms that shape human behavior. When used strategically, behavioral science holds the potential to drive down resource use, drive up profits, and generate measurable gains in conservation and efficiency. WaterSmart will present on how the water sector can employ behavioral science to nudge residential rate-payers to use water more efficiently and help them save money. Utilities can use behavioral science to influence people's reaction to leaks. 5% of Single Family Residential (SFR) metered water use can be attributed to leaks. This value potentially skews even higher for MultiFamily (MF) and Commercial accounts given that it can get lost in the noise of daily consumption. Existing leak detection algorithms in the market are not sophisticated enough to detect leaks for a MF or Commercial property. Leveraging data from utilities on known leak events at MF and Commercial buildings allowed WaterSmart to train a machine learning model to identify key features in the load shape and accurately detect these types of water use events. The outcome of the model is a leak amount and confidence level for each irregular usage event. The model also incorporates record feedback from users on the type of leak event, and the accuracy of the alert. When WaterSmart leverages this data model with social norms messaging, we've been able to improve water demand management for MF and Commercial properties. Experiences from leak detection and resolution in the SFR space will also be

  15. A system for distributed intrusion detection

    Energy Technology Data Exchange (ETDEWEB)

    Snapp, S.R.; Brentano, J.; Dias, G.V.; Goan, T.L.; Heberlein, L.T.; Ho, Che-Lin; Levitt, K.N.; Mukherjee, B. (California Univ., Davis, CA (USA). Div. of Computer Science); Grance, T. (Air Force Cryptologic Support Center, San Antonio, TX (USA)); Mansur, D.L.; Pon, K.L. (Lawrence Livermore National Lab., CA (USA)); Smaha, S.E. (Haystack Labs., Inc., Austin, TX (USA))

    1991-01-01

    The study of providing security in computer networks is a rapidly growing area of interest because the network is the medium over which most attacks or intrusions on computer systems are launched. One approach to solving this problem is the intrusion-detection concept, whose basic premise is that not only abandoning the existing and huge infrastructure of possibly-insecure computer and network systems is impossible, but also replacing them by totally-secure systems may not be feasible or cost effective. Previous work on intrusion-detection systems were performed on stand-alone hosts and on a broadcast local area network (LAN) environment. The focus of our present research is to extend our network intrusion-detection concept from the LAN environment to arbitarily wider areas with the network topology being arbitrary as well. The generalized distributed environment is heterogeneous, i.e., the network nodes can be hosts or servers from different vendors, or some of them could be LAN managers, like our previous work, a network security monitor (NSM), as well. The proposed architecture for this distributed intrusion-detection system consists of the following components: a host manager in each host; a LAN manager for monitoring each LAN in the system; and a central manager which is placed at a single secure location and which receives reports from various host and LAN managers to process these reports, correlate them, and detect intrusions. 11 refs., 2 figs.

  16. Force protection demining system (FPDS) detection subsystem

    Science.gov (United States)

    Zachery, Karen N.; Schultz, Gregory M.; Collins, Leslie M.

    2005-06-01

    This study describes the U.S. Army Force Protection Demining System (FPDS); a remotely-operated, multisensor platform developed for reliable detection and neutralization of both anti-tank and anti-personnel landmines. The ongoing development of the prototype multisensor detection subsystem is presented, which integrates an advanced electromagnetic pulsed-induction array and ground penetrating synthetic aperture radar array on a single standoff platform. The FPDS detection subsystem is mounted on a robotic rubber-tracked vehicle and incorporates an accurate and precise navigation/positioning module making it well suited for operation in varied and irregular terrains. Detection sensors are optimally configured to minimize interference without loss in sensitivity or performance. Mine lane test data acquired from the prototype sensors are processed to extract signal- and image-based features for automatic target recognition. Preliminary results using optimal feature and classifier selection indicate the potential of the system to achieve high probabilities of detection while minimizing false alarms. The FPDS detection software system also exploits modern multi-sensor data fusion algorithms to provide real-time detection and discrimination information to the user.

  17. Expert System Detects Power-Distribution Faults

    Science.gov (United States)

    Walters, Jerry L.; Quinn, Todd M.

    1994-01-01

    Autonomous Power Expert (APEX) computer program is prototype expert-system program detecting faults in electrical-power-distribution system. Assists human operators in diagnosing faults and deciding what adjustments or repairs needed for immediate recovery from faults or for maintenance to correct initially nonthreatening conditions that could develop into faults. Written in Lisp.

  18. Bolidozor - Distributed radio meteor detection system

    CERN Document Server

    Kakona, Jakub; Kakona, Martin

    2016-01-01

    Most of the meteor radioastronomical radars are backscatter radars which cover only a small area of the atmosphere. Therefore a daytime meteor flux models are based on sparse data collected by only a few radar systems. To solve this issue, a radar system with a wide coverage is required. We present a new approach of open-source multi-static radio meteor detection system which could be distributed over a large area. This feature allows us to detect meteor events taking place over a larger area as well and gather more uniform data about meteor flux and possibly about meteor trajectories.

  19. Improved biosensor-based detection system

    DEFF Research Database (Denmark)

    2015-01-01

    Described is a new biosensor-based detection system for effector compounds, useful for in vivo applications in e.g. screening and selecting of cells which produce a small molecule effector compound or which take up a small molecule effector compound from its environment. The detection system...... comprises a protein or RNA-based biosensor for the effector compound which indirectly regulates the expression of a reporter gene via two hybrid proteins, providing for fewer false signals or less 'noise', tuning of sensitivity or other advantages over conventional systems where the biosensor directly...

  20. A cable detection lidar system for helicopters

    Science.gov (United States)

    Grossmann, Benoist; Capbern, Alain; Defour, Martin; Fertala, Remi

    1992-01-01

    Helicopters in low-level flight are endangered by power lines or telephone wires, especially when flying at night and under poor visibility conditions. In order to prevent 'wire strike', Thomson has developed a lidar system consisting of a pulsed diode laser emitting in the near infrared region (lambda = 0.9 microns). The HOWARD (Helicopter Obstacle Warning and Detection) System utilizes a high repetition rate diode laser (PRE = 20 KHz) along with counter-rotating prisms for laser beam deflection with a total field of view of 30 degrees. This system was successfully field tested in 1991. HOWARD can detect one inch wires at ranges up to 200 meters. We are presently in the process of developing a flyable compact lidar system capable of detection ranges in the order of 400 meters.

  1. Intrusion Detection System Using Advanced Honeypots

    CERN Document Server

    Singh, Ram Kumar

    2009-01-01

    The exponential growth of Internet traffic has made public servers increasingly vulnerable to unauthorized accesses and intrusions. In addition to maintaining low latency for the client, filtering unauthorized accesses has become one of the major concerns of a server maintainer. This implementation of an Intrusion Detection System distinguishes between the traffic coming from clients and the traffic originated from the attackers, in an attempt to simultaneously mitigate the problems of both latency and security. We then present the results of a series of stress and scalability tests, and suggest a number of potential uses for such a system. As computer attacks are becoming more and more difficult to identify the need for better and more efficient intrusion detection systems increases. The main problem with current intrusion detection systems is high rate of false alarms. Using honeypots provides effective solution to increase the security.

  2. Fault detection and isolation for complex system

    Science.gov (United States)

    Jing, Chan Shi; Bayuaji, Luhur; Samad, R.; Mustafa, M.; Abdullah, N. R. H.; Zain, Z. M.; Pebrianti, Dwi

    2017-07-01

    Fault Detection and Isolation (FDI) is a method to monitor, identify, and pinpoint the type and location of system fault in a complex multiple input multiple output (MIMO) non-linear system. A two wheel robot is used as a complex system in this study. The aim of the research is to construct and design a Fault Detection and Isolation algorithm. The proposed method for the fault identification is using hybrid technique that combines Kalman filter and Artificial Neural Network (ANN). The Kalman filter is able to recognize the data from the sensors of the system and indicate the fault of the system in the sensor reading. Error prediction is based on the fault magnitude and the time occurrence of fault. Additionally, Artificial Neural Network (ANN) is another algorithm used to determine the type of fault and isolate the fault in the system.

  3. Leaking Underground Storage Tank Sites in Iowa

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — Leaking Underground Storage Tank (LUST) sites where petroleum contamination has been found. There may be more than one LUST site per UST site.

  4. Leaking Underground Storage Tank (LUST) Trust Fund

    Science.gov (United States)

    In 1986, Congress created the Leaking Underground Storage Tank (LUST) Trust Fund to address releases from federally regulated underground storage tanks (USTs) by amending Subtitle I of the Solid Waste Disposal Act.

  5. Signature Based Intrusion Detection System Using SNORT

    Directory of Open Access Journals (Sweden)

    Vinod Kumar

    2012-11-01

    Full Text Available Now a day’s Intrusion Detection systems plays very important role in Network security. As the use of internet is growing rapidly the possibility of attack is also increasing in that ratio. People are using signature based IDS’s. Snort is mostly used signature based IDS because of it is open source software. World widely it is used in intrusion detection and prevention domain. Basic analysis and security engine (BASE is also used to see the alerts generated by Snort. In the paper we have implementation the signature based intrusion detection using Snort. Our work will help to novel user to understand the concept of Snort based IDS.

  6. Maximum Temperature Detection System for Integrated Circuits

    Science.gov (United States)

    Frankiewicz, Maciej; Kos, Andrzej

    2015-03-01

    The paper describes structure and measurement results of the system detecting present maximum temperature on the surface of an integrated circuit. The system consists of the set of proportional to absolute temperature sensors, temperature processing path and a digital part designed in VHDL. Analogue parts of the circuit where designed with full-custom technique. The system is a part of temperature-controlled oscillator circuit - a power management system based on dynamic frequency scaling method. The oscillator cooperates with microprocessor dedicated for thermal experiments. The whole system is implemented in UMC CMOS 0.18 μm (1.8 V) technology.

  7. WikiLeaks: neue Dimensionen des Medienaktivismus

    OpenAIRE

    Stalder, Felix

    2011-01-01

    "Mit WikiLeaks hat der Medienaktivismus eine neue Dimension erreicht. WikiLeaks versteht die neuen sozio-technischen Möglichkeiten und institutionellen Widersprüche, die die gegenwärtige Phase der Entwicklung der Netzwerkgesellschaft kennzeichnen, für sein Projekt nutzbar zu machen. Politisch bleibt das Projekt allerdings schwer kategorisierbar, da es gleichzeitig eine markt-libertäre und eine institutionskritische Haltung vertritt, gleichermassen staatliche wie privat-wirtscha...

  8. A LOW-COST GPR GAS PIPE & LEAK DETECTOR

    Energy Technology Data Exchange (ETDEWEB)

    David Cist; Alan Schutz

    2005-03-30

    A light-weight, easy to use ground penetrating radar (GPR) system for tracking metal/non-metal pipes has been developed. A pre-production prototype instrument has been developed whose production cost and ease of use should fit important market niches. It is a portable tool which is swept back and forth like a metal detector and which indicates when it goes over a target (metal, plastic, concrete, etc.) and how deep it is. The innovation of real time target detection frees the user from having to interpret geophysical data and instead presents targets as dots on the screen. Target depth is also interpreted automatically, relieving the user of having to do migration analysis. In this way the user can simply walk around looking for targets and, by ''connecting the dots'' on the GPS screen, locate and follow pipes in real time. This is the first tool known to locate metal and non-metal pipes in real time and map their location. This prototype design is similar to a metal detector one might use at the beach since it involves sliding a lightweight antenna back and forth over the ground surface. The antenna is affixed to the end of an extension that is either clipped to or held by the user. This allows him to walk around in any direction, either looking for or following pipes with the antenna location being constantly recorded by the positioning system. Once a target appears on the screen, the user can locate by swinging the unit to align the cursor over the dot. Leak detection was also a central part of this project, and although much effort was invested into its development, conclusive results are not available at the time of the writing of this document. Details of the efforts that were made as a part of this cooperative agreement are presented.

  9. Damage detection in initially nonlinear systems

    Energy Technology Data Exchange (ETDEWEB)

    Bornn, Luke [Los Alamos National Laboratory; Farrar, Charles [Los Alamos National Laboratory; Park, Gyuhae [Los Alamos National Laboratory

    2009-01-01

    The primary goal of Structural Health Monitoring (SHM) is to detect structural anomalies before they reach a critical level. Because of the potential life-safety and economic benefits, SHM has been widely studied over the past decade. In recent years there has been an effort to provide solid mathematical and physical underpinnings for these methods; however, most focus on systems that behave linearly in their undamaged state - a condition that often does not hold in complex 'real world' systems and systems for which monitoring begins mid-lifecycle. In this work, we highlight the inadequacy of linear-based methodology in handling initially nonlinear systems. We then show how the recently developed autoregressive support vector machine (AR-SVM) approach to time series modeling can be used for detecting damage in a system that exhibits initially nonlinear response. This process is applied to data acquired from a structure with induced nonlinearity tested in a laboratory environment.

  10. Mobile natural gas leak surveys indicate that two utilities have high false negative rates

    Science.gov (United States)

    von Fischer, J. C.; Brewer, P. E.; Chamberlain, S.; Gaylord, A.; von Fischer, J.

    2016-12-01

    In the distribution systems that carry natural gas to consumers, leaks need to be discovered for safety reasons and to reduce greenhouse gas emissions. However, few utilities have adopted newer laser-based technologies that have greater sensitivity and precision, and instead rely on "industry standard" equipment that is far less sensitive. In partnership with the Environmental Defense Fund and Google, we mapped natural gas leaks in the domains of two anonymous utilities (Utility "A" and "B") using high sensitivity Picarro methane analyzers in Google Street View Cars. Surprisingly, when we shared these results with utilities, their survey crews were unable to find most of the leaks that our survey indicated (84% in A and 80% in B). To investigate this phenomenon, our team visited a subset of the leaks in each utility domain (n=32 in A and n=30 in B), and worked alongside utility surveyors to search the leak indication area, using a Los Gatos Research ultraportable methane analyzer to pinpoint leak locations. We found evidence of natural gas leaks at 69% and 68% of the locations in Utilities A and B respectively where survey crews had found nothing. We describe this as a "false negative" rate for the utility because the utility survey falsely indicated that there was no leak at these locations. Of these false negatives, 7% (n=2 of 32 in A, n=2 of 30 in B) were determined to be Grade 1 leaks requiring immediate repair due to high safety risk. Instrument sensitivity appears to explain some of the false negative rates. In particular, use of some industry standard equipment appears to have created a false sense of confidence among utility surveyors that leaks were not present. However, there was also evidence of communication failures and that surveyors did not use optimal approaches in their search. Based on these findings, we suggest that: 1) mobile deployment of high-precision methane analyzers can help find more natural gas leaks, and 2) use of some hand-held survey

  11. 从维基解密看加强我国信息安全体系建设%Strengthening construction of information security system in China in view of WikiLeaks

    Institute of Scientific and Technical Information of China (English)

    颜圣哲

    2011-01-01

    在"维基解密"的背景下,以应对全球信息安全挑战和加强我国信息安全工作为目的,首先分析国外信息安全发展历程和经验成果,在介绍信息安全、军事信息安全等概念基础上,结合我国及我军信息化建设实际情况,提出我军信息安全体系是我国信息安全中的重要组成部分,并指出构建我军信息安全体系的迫切性,最后构造我军信息安全体系.%In view of "WikiLeaks" under the background of global information security Challenges and strengthening our information security, this paper firstly analyzes other countries’ information security development history and experience in the introduction of concepts. such as information security and military information security, put forward that our military information security system is important composition fo our information security. The urgency and the security system is pointed ont.

  12. Analysis of Pressurized Water Reactor Primary Coolant Leak Events Caused by Thermal Fatigue

    Energy Technology Data Exchange (ETDEWEB)

    Atwood, Corwin Lee; Shah, Vikram Naginbhai; Galyean, William Jospeh

    1999-09-01

    We present statistical analyses of pressurized water reactor (PWR) primary coolant leak events caused by thermal fatigue, and discuss their safety significance. Our worldwide data contain 13 leak events (through-wall cracking) in 3509 reactor-years, all in stainless steel piping with diameter less than 25 cm. Several types of data analysis show that the frequency of leak events (events per reactor-year) is increasing with plant age, and the increase is statistically significant. When an exponential trend model is assumed, the leak frequency is estimated to double every 8 years of reactor age, although this result should not be extrapolated to plants much older than 25 years. Difficulties in arresting this increase include lack of quantitative understanding of the phenomena causing thermal fatigue, lack of understanding of crack growth, and difficulty in detecting existing cracks.

  13. Active fault detection in MIMO systems

    DEFF Research Database (Denmark)

    Niemann, Hans Henrik; Poulsen, Niels Kjølstad

    2014-01-01

    The focus in this paper is on active fault detection (AFD) for MIMO systems with parametric faults. The problem of design of auxiliary inputs with respect to detection of parametric faults is investigated. An analysis of the design of auxiliary inputs is given based on analytic transfer functions...... from auxiliary input to residual outputs. The analysis is based on a singular value decomposition of these transfer functions Based on this analysis, it is possible to design auxiliary input as well as design of the associated residual vector with respect to every single parametric fault in the system...

  14. System for particle concentration and detection

    Science.gov (United States)

    Morales, Alfredo M.; Whaley, Josh A.; Zimmerman, Mark D.; Renzi, Ronald F.; Tran, Huu M.; Maurer, Scott M.; Munslow, William D.

    2013-03-19

    A new microfluidic system comprising an automated prototype insulator-based dielectrophoresis (iDEP) triggering microfluidic device for pathogen monitoring that can eventually be run outside the laboratory in a real world environment has been used to demonstrate the feasibility of automated trapping and detection of particles. The system broadly comprised an aerosol collector for collecting air-borne particles, an iDEP chip within which to temporarily trap the collected particles and a laser and fluorescence detector with which to induce a fluorescence signal and detect a change in that signal as particles are trapped within the iDEP chip.

  15. Past, Present and Future of Linac 2 Vacuum System

    CERN Document Server

    Mahner, E

    2011-01-01

    This note aims to review the past, present, and future operation of CERN's Linac 2 vacuum system. The machine vacuum system layout with its major components is summarized. Operational problems arising in 2006 yielded to a leak test campaign of the whole machine, which detected a new, major leak on tank 3. Details about the mitigation of this leak are described as well as additional diagnostics installed during shutdown 2006/07. The pressure evolution of the most critical vacuum sector is analyzed. A statistics of vacuum system faults observed since 2000 is presented and compared with other systems. Finally, a perspective for the vacuum system operation until 2017/18 is outlined.

  16. Materiel requirements for airborne minefield detection system

    Science.gov (United States)

    Bertsche, Karl A.; Huegle, Helmut

    1997-07-01

    Within the concept study, Material Requirements for an airborne minefield detection systems (AMiDS) the following topics were investigated: (i) concept concerning airborne minefield detection technique sand equipment, (ii) verification analysis of the AMiDS requirements using simulation models and (iii) application concept of AMiDS with regard o tactics and military operations. In a first approach the problems concerning unmanned airborne minefield detection techniques within a well-defined area were considered. The complexity of unmanned airborne minefield detection is a result of the following parameters: mine types, mine deployment methods, tactical requirements, topography, weather conditions, and the size of the area to be searched. In order to perform the analysis, a simulation model was developed to analyze the usability of the proposed remote controlled air carriers. The basic flight patterns for the proposed air carriers, as well as the preparation efforts of military operations and benefits of such a system during combat support missions were investigated. The results of the conceptual study showed that a proposed remote controlled helicopter drone could meet the stated German MOD scanning requirements of mine barriers. Fixed wing air carriers were at a definite disadvantage because of their inherently large turning loops. By implementing a mine detection system like AMiDS minefields can be reconnoitered before an attack. It is therefore possible either to plan, how the minefields can be circumvented or where precisely breaching lanes through the mine barriers are to be cleared for the advancing force.

  17. Bioinspired Sensory Systems for Shear Flow Detection

    Science.gov (United States)

    Colvert, Brendan; Chen, Kevin K.; Kanso, Eva

    2017-03-01

    Aquatic organisms such as copepods exhibit remarkable responses to changes in ambient flows, especially shear gradients, when foraging, mating and escaping. To accomplish these tasks, the sensory system of the organism must decode the local sensory measurements to detect the flow properties. Evidence suggests that organisms sense differences in the hydrodynamic signal rather than absolute values of the ambient flow. In this paper, we develop a mathematical framework for shear flow detection using a bioinspired sensory system that measures only differences in velocity. We show that the sensory system is capable of reconstructing the properties of the ambient shear flow under certain conditions on the flow sensors. We discuss these conditions and provide explicit expressions for processing the sensory measurements and extracting the flow properties. These findings suggest that by combining suitable velocity sensors and physics-based methods for decoding sensory measurements, we obtain a powerful approach for understanding and developing underwater sensory systems.

  18. DCE Bio Detection System Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Lind, Michael A.; Batishko, Charles R.; Morgen, Gerald P.; Owsley, Stanley L.; Dunham, Glen C.; Warner, Marvin G.; Willett, Jesse A.

    2007-12-01

    The DCE (DNA Capture Element) Bio-Detection System (Biohound) was conceived, designed, built and tested by PNNL under a MIPR for the US Air Force under the technical direction of Dr. Johnathan Kiel and his team at Brooks City Base in San Antonio Texas. The project was directed toward building a measurement device to take advantage of a unique aptamer based assay developed by the Air Force for detecting biological agents. The assay uses narrow band quantum dots fluorophores, high efficiency fluorescence quenchers, magnetic micro-beads beads and selected aptamers to perform high specificity, high sensitivity detection of targeted biological materials in minutes. This final report summarizes and documents the final configuration of the system delivered to the Air Force in December 2008

  19. Coaxial direct-detection lidar-system

    DEFF Research Database (Denmark)

    2014-01-01

    The invention relates to a coaxial direct-detection LIDAR system for measuring velocity, temperature and/or particulate density. The system comprises a laser source for emitting a laser light beam having a lasing center frequency along an emission path. The system further comprises an optical...... frequency and/or the center filter frequency may be scanned. The invention further relates to an aircraft airspeed measurement device, and a wind turbine airspeed measurement device comprising the LIDAR system....... delivery system arranged in the emission path of the laser source, the optical delivery system being arranged for delivering the laser light beam in a measuring direction, the optical delivery system further being configured for collecting a return signal backscattered along the measuring direction...

  20. Landmine detection by 3D GPR system

    Science.gov (United States)

    Sato, Motoyuki; Yokota, Yuya; Takahashi, Kazunori; Grasmueck, Mark

    2012-06-01

    In order to demonstrate the possibility of Ground Penetrating Radar (GPR) for detection of small buried objects such as landmine and UXO, conducted demonstration tests by using the 3DGPR system, which is a GPR system combined with high accuracy positing system using a commercial laser positioning system (iGPS). iGPS can provide absolute and better than centimetre precise x,y,z coordinates to multiple mine sensors at the same time. The developed " 3DGPR" system is efficient and capable of high-resolution 3D shallow subsurface scanning of larger areas (25 m2 to thousands of square meters) with irregular topography . Field test by using a 500MHz GPR system equipped with 3DGPR system was conducted. PMN-2 and Type-72 mine models have been buried at the depth of 5-20cm in sand. We could demonstrate that the 3DGPR can visualize each of these buried land mines very clearly.

  1. Intrusion Detection System Visualization of Network Alerts

    Science.gov (United States)

    2010-07-01

    Intrusion Detection System Visualization of Network Alerts Dolores M. Zage and Wayne M. Zage Ball State University Final Report July 2010...contracts. Staff Wayne Zage, Director of the S2ERC and Professor, Department of Computer Science, Ball State University Dolores Zage, Research

  2. Detection of cardiovascular anomalies: Hybrid systems approach

    KAUST Repository

    Ledezma, Fernando

    2012-06-06

    In this paper, we propose a hybrid interpretation of the cardiovascular system. Based on a model proposed by Simaan et al. (2009), we study the problem of detecting cardiovascular anomalies that can be caused by variations in some physiological parameters, using an observerbased approach. We present the first numerical results obtained. © 2012 IFAC.

  3. An FPGA-Based People Detection System

    Directory of Open Access Journals (Sweden)

    James J. Clark

    2005-05-01

    Full Text Available This paper presents an FPGA-based system for detecting people from video. The system is designed to use JPEG-compressed frames from a network camera. Unlike previous approaches that use techniques such as background subtraction and motion detection, we use a machine-learning-based approach to train an accurate detector. We address the hardware design challenges involved in implementing such a detector, along with JPEG decompression, on an FPGA. We also present an algorithm that efficiently combines JPEG decompression with the detection process. This algorithm carries out the inverse DCT step of JPEG decompression only partially. Therefore, it is computationally more efficient and simpler to implement, and it takes up less space on the chip than the full inverse DCT algorithm. The system is demonstrated on an automated video surveillance application and the performance of both hardware and software implementations is analyzed. The results show that the system can detect people accurately at a rate of about 2.5 frames per second on a Virtex-II 2V1000 using a MicroBlaze processor running at 75 MHz, communicating with dedicated hardware over FSL links.

  4. Leak test of the charcoal filter in the nuclear facility

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Sang Yeol; Lee, Key Soon; Hong, Kwon Pyo; Oh, Yon Woo; Park, Dae Kyu; Ahn, Sang Bok; Choo, Yong Sun; Kim, Sung Jung

    1998-06-01

    In the heating, ventilation and air conditioning(HVAC) system, pre-filter, HEPA(high efficiency particle air) filter and charcoal filter are instrumented in order to filter off the radioactive substance in the nuclear facility. Equipment of the charcoal filter off the radioactive substance in the nuclear facility. Equipment of the charcoal filter at the hot cell where manipulates the nuclear fuel irradiated in the nuclear reactor is essential for shutting off the leakage of the radioiodine which is produced from the cutting procedures of nuclear fuel. Also, the leak test of installed filter should be performed perfectly. In addition, charcoal filter is instrumented to filter the radioactive gas such as radioiodine which is produced in the nuclear facility. In this technical report, the theoretical discussion, the experimental procedures and the precautions of the leak test of charcoal filter are described. (author). 8 refs., 4 tabs., 8 figs.

  5. Fault Detection and Control of Process Systems

    Directory of Open Access Journals (Sweden)

    Vu Trieu Minh

    2007-01-01

    Full Text Available This paper develops a stochastic hybrid model-based control system that can determine online the optimal control actions, detect faults quickly in the control process, and reconfigure the controller accordingly using interacting multiple-model (IMM estimator and generalized predictive control (GPC algorithm. A fault detection and control system consists of two main parts: the first is the fault detector and the second is the controller reconfiguration. This work deals with three main challenging issues: design of fault model set, estimation of stochastic hybrid multiple models, and stochastic model predictive control of hybrid multiple models. For the first issue, we propose a simple scheme for designing faults for discrete and continuous random variables. For the second issue, we consider and select a fast and reliable fault detection system applied to the stochastic hybrid system. Finally, we develop a stochastic GPC algorithm for hybrid multiple-models controller reconfiguration with soft switching signals based on weighted probabilities. Simulations for the proposed system are illustrated and analyzed.

  6. A FRAMEWORK FOR AUTOMATED CHANGE DETECTION SYSTEM

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    To enhance the ability of remote sensing system to provide accurate,timely,and c omplete geo_spatial information at regional or global scale,an automated change detection system has been and will continue to be one of the important and chall enging problems in remote sensing.In this paper,the authors propose a framework for auto mated change detection system at landscape level using various geo_spatial data sources including multi_sensor remotely sensed imagery and ancillary data layers .In this framework,database is the central part and some associated techniques a re discussed.These techniques includes five subsystems:automated feature_based i mage registration,automated change finding,automated change feature extraction a nd identification,intelligent change recognition,change accuracy assessment and database updating and visualization.

  7. Chemical detection system and related methods

    Energy Technology Data Exchange (ETDEWEB)

    Caffrey, Augustine J.; Chichester, David L.; Egger, Ann E.; Krebs, Kenneth M.; Seabury, Edward H.; Van Siclen, Clinton D.; Wharton, C. Jayson; Zabriskie, John M.

    2017-06-27

    A chemical detection system includes a frame, an emitter coupled to the frame, and a detector coupled to the frame proximate the emitter. The system also includes a shielding system coupled to the frame and positioned at least partially between the emitter and the detector, wherein the frame positions a sensing surface of the detector in a direction substantially parallel to a plane extending along a front portion of the frame. A method of analyzing composition of a suspect object includes directing neutrons at the object, detecting gamma rays emitted from the object, and communicating spectrometer information regarding the gamma rays. The method also includes presenting a GUI to a user with a dynamic status of an ongoing neutron spectroscopy process. The dynamic status includes a present confidence for a plurality of compounds being present in the suspect object responsive to changes in the spectrometer information during the ongoing process.

  8. APDS: The Autonomous Pathogen Detection System

    Energy Technology Data Exchange (ETDEWEB)

    Hindson, B; Makarewicz, A; Setlur, U; Henderer, B; McBride, M; Dzenitis, J

    2004-10-04

    We have developed and tested a fully autonomous pathogen detection system (APDS) capable of continuously monitoring the environment for airborne biological threat agents. The system was developed to provide early warning to civilians in the event of a bioterrorism incident and can be used at high profile events for short-term, intensive monitoring or in major public buildings or transportation nodes for long-term monitoring. The APDS is completely automated, offering continuous aerosol sampling, in-line sample preparation fluidics, multiplexed detection and identification immunoassays, and nucleic-acid based polymerase chain reaction (PCR) amplification and detection. Highly multiplexed antibody-based and duplex nucleic acid-based assays are combined to reduce false positives to a very low level, lower reagent costs, and significantly expand the detection capabilities of this biosensor. This article provides an overview of the current design and operation of the APDS. Certain sub-components of the ADPS are described in detail, including the aerosol collector, the automated sample preparation module that performs multiplexed immunoassays with confirmatory PCR, and the data monitoring and communications system. Data obtained from an APDS that operated continuously for seven days in a major U.S. transportation hub is reported.

  9. The Mount Rainier Lahar Detection System

    Science.gov (United States)

    Lockhart, A. B.; Murray, T. L.

    2003-12-01

    To mitigate the risk of unheralded lahars from Mount Rainier, the U.S. Geological Survey, in cooperation with Pierce County, Washington, installed a lahar-detection system on the Puyallup and Carbon rivers that originate on Mount Rainier's western slopes. The system, installed in 1998, is designed to automatically detect the passage of lahars large enough to potentially affect populated areas downstream (approximate volume threshold 40 million cubic meters), while ignoring small lahars, earthquakes, extreme weather and floods. Along each river valley upstream, arrays of independent lahar-monitoring stations equipped with geophones and short tripwires telemeter data to a pair of redundant computer base stations located in and near Tacoma at existing public safety facilities that are staffed around the clock. Monitored data consist of ground-vibration levels, tripwire status, and transmissions at regular intervals. The base stations automatically evaluate these data to determine if a dangerous lahar is passing through the station array. The detection algorithm requires significant ground vibration to occur at those stations in the array that are above the anticipated level of inundation, while lower level `deadman' stations, inundated by the flow, experience tripwire breakage or are destroyed. Once a base station detects a lahar, it alerts staff who execute a call-down of public-safety officials and schools, initiating evacuation of areas potentially at risk. Because the system's risk-mitigation task imposes high standards of reliability on all components, it has been under test for several years. To date, the system has operated reliably and without false alarms, including during the nearby M6.8 Nisqually Earthquake on February 28, 2001. The system is being turned over to Pierce County, and activated as part of their lahar warning system.

  10. NSRD-10: Leak Path Factor Guidance Using MELCOR

    Energy Technology Data Exchange (ETDEWEB)

    Louie, David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Humphries, Larry L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-03-01

    Estimates of the source term from a U.S. Department of Energy (DOE) nuclear facility requires that the analysts know how to apply the simulation tools used, such as the MELCOR code, particularly for a complicated facility that may include an air ventilation system and other active systems that can influence the environmental pathway of the materials released. DOE has designated MELCOR 1.8.5, an unsupported version, as a DOE ToolBox code in its Central Registry, which includes a leak-path-factor guidance report written in 2004 that did not include experimental validation data. To continue to use this MELCOR version requires additional verification and validations, which may not be feasible from a project cost standpoint. Instead, the recent MELCOR should be used. Without any developer support and lack of experimental data validation, it is difficult to convince regulators that the calculated source term from the DOE facility is accurate and defensible. This research replaces the obsolete version in the 2004 DOE leak path factor guidance report by using MELCOR 2.1 (the latest version of MELCOR with continuing modeling development and user support) and by including applicable experimental data from the reactor safety arena and from applicable experimental data used in the DOE-HDBK-3010. This research provides best practice values used in MELCOR 2.1 specifically for the leak path determination. With these enhancements, the revised leak-path-guidance report should provide confidence to the DOE safety analyst who would be using MELCOR as a source-term determination tool for mitigated accident evaluations.

  11. Biliary leaks after laparoscopic cholecystectomy:timetostentortimetodrain

    Institute of Scientific and Technical Information of China (English)

    Haim Pinkas; Patrick G. Brady

    2008-01-01

    BACKGROUND: Endoscopic retrograde cholangiopan-creatography (ERCP) with placement of a biliary stent or nasobiliary (NB) drain is the procedure of choice for treatment of post-cholecystectomy bile duct leaks. The aim of this study was to compare the effect of NB drainage versus internal biliary stenting on rates of leak closure, time elapsed until drain or stent removal, length of hospital stay and number of required endoscopic procedures. METHODS: Charts were reviewed on 20 patients who underwent laparoscopic cholecystectomy complicated by Luschka or cystic duct leak. Ten patients were treated with NB drains connected to low intermittent suction and repeat NB cholangiograms were performed until leak closure was observed. Ten patients were treated with internal biliary stents. Biliary sphincterotomies were performed for stone extraction or a presumed papillary stenosis. Large bilomas were drained percutaneously prior to stenting. RESULTS: In all 20 patients, a cholangiogram and successful placement of a NB drain or internal stent was achieved. Four patients (20%) were found to have bile duct stones, which were extracted following a sphincterotomy. Sixteen patients required percutaneous drains to evacuate large bilomas prior to biliary instrumentation. Fifteen cystic duct leaks and 5 Luschka duct leaks were reviewed. There were no complications related to ERCP. Closure of the leak was documented within 2 to 11 days (mean 4.7±0.9 days) in patients receiving a NB drain. The drains were removed non-endoscopically following leak closure. The internal stent group required stenting for 14 to 53 days (mean 29.1±4.4 days). The stent was then removed endoscopically after documentation of leak closure. Bile leaks following laparoscopic cholecystectomy closed rapidly after NB drainage and did not require repeat endoscopy for removal of the NB drain, resulting in fewer ERCPs required for treatment of biliary leaks. Internal biliary stents were in place longer owing

  12. Flammable Gas Detection for the D-Zero Gas System

    Energy Technology Data Exchange (ETDEWEB)

    Spires, L.D.; Foglesong, J.; /Fermilab

    1991-02-11

    The use of flammable gas and high voltage in detector systems is common in many experiments at Fermilab. To mitigate the hazards associated with these systems, Fermilab Engineering Standard SD-45B (Ref. 1) was adopted. Since this note is meant to be a guide and not a mandatory standard, each experiment is reviewed for compliance with SD-45B by the flammable gas safety subcommittee. Currently, there are only two types of flammable gas in use, ethane (Appendix A) and methane (Appendix B). The worst flammable-gas case is C2H6 (ethane), which has an estimated flow rate that is 73% of the CH4 (methane) flow but a heat of combustion (in kcal/g-mole) that is 173% of that of methane. In the worst case, if ethane were to spew through its restricting orifice into its gas line at 0 psig and then through a catastrophic leak into Room 215 (TRD) or Room 511 (CDC/FDCNTX), the time that would be required to build up a greater than Class 1 inventory (0.4kg H2 equivalent) would be 5.2 hours (Ref. 2). Therefore a worst-case flammable gas leak would have to go undetected for over 5 hours in order to transform a either mixing room to an environment with a Risk Class greater than Class 1. The mixing systems, gas lines, and detectors themselves will be thoroughly leak checked prior to active service. All vessels that are part of the mixing systems will be protected from overpressure by safety valves vented outside the building. Both the input and output of all detector volumes are protected from overpressure in the same way. The volume immediately outside the central tracking detectors is continuously purged by nitrogen from boiloff from the main nitrogen dewar at the site. However, if flammable gas were to build up in the mixing rooms or particular detector areas, no matter how unlikely, flammable gas detectors that are part of the interlock chain of each gas mixing system will shut down the appropriate system. This includes shutting off the output of flammable gas manifolds within the

  13. The synchronous active neutron detection assay system

    Energy Technology Data Exchange (ETDEWEB)

    Pickrell, M.M.; Kendall, P.K.

    1994-08-01

    We have begun to develop a novel technique for active neutron assay of fissile material in spent nuclear fuel. This approach will exploit a 14-MeV neutron generator developed by Schlumberger. The technique, termed synchronous active neutron detection (SAND), follows a method used routinely in other branches of physics to detect very small signals in presence of large backgrounds. Synchronous detection instruments are widely available commercially and are termed ``lock-in`` amplifiers. We have implemented a digital lock-in amplifier in conjunction with the Schlumberger neutron generator to explore the possibility of synchronous detection with active neutrons. The Schlumberger system can operate at up to a 50% duty factor, in effect, a square wave of neutron yield. Results are preliminary but promising. The system is capable of resolving the fissile material contained in a small fraction of the fuel rods in a cold fuel assembly; it also appears resilient to background neutron interference. The interrogating neutrons appear to be non-thermal and penetrating. Work remains to fully explore relevant physics and optimize instrument design.

  14. Detecting Triple Systems with Gravitational Wave Observations

    Science.gov (United States)

    Meiron, Yohai; Kocsis, Bence; Loeb, Abraham

    2017-01-01

    The Laser Interferometer Gravitational Wave Observatory (LIGO) has recently discovered gravitational waves (GWs) emitted by merging black hole binaries. We examine whether future GW detections may identify triple companions of merging binaries. Such a triple companion causes variations in the GW signal due to: (1) the varying path length along the line of sight during the orbit around the center of mass; (2) relativistic beaming, Doppler, and gravitational redshift; (3) the variation of the “light”-travel time in the gravitational field of the triple companion; and (4) secular variations of the orbital elements. We find that the prospects for detecting a triple companion are the highest for low-mass compact object binaries which spend the longest time in the LIGO frequency band. In particular, for merging neutron star binaries, LIGO may detect a white dwarf or M-dwarf perturber at a signal-to-noise ratio of 8, if it is within 0.4 {R}ȯ distance from the binary and the system is within a distance of 100 Mpc. Stellar mass (supermassive) black hole perturbers may be detected at a factor 5 × (103×) larger separations. Such pertubers in orbit around a merging binary emit GWs at frequencies above 1 mHz detectable by the Laser Interferometer Space Antenna in coincidence.

  15. Installation and Commissioning of the Main Magnet Elevating System for CYCIAE-100

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    The main magnet elevating system is a key part for CYCIAE-100. The raising device will play an important role throughout the process of installation, magnetic mapping, vacuum leak detection, beam commissioning, and maintenance.

  16. Fabrication of Microfluidic Fiber Chip Detection System

    Institute of Scientific and Technical Information of China (English)

    Bo Su; Da-fu Cui; Chang-chun Liu; Xing Chen

    2006-01-01

    The diameter of the excitation beam was decreased greatly by integrating the fiber on the microfluidic chip as light propagation medium. The coupling efficiency of the fiber was improved with optical fiber collimation device coupling beam.The chip was placed in the darkroom to avoid the interference of the external light. The cost of the instrument was decreased with a high brightness blue LED as excitation source; the performance of the system was valuated by the determination of FITC fluorescein with a minimum detectable concentration of 2.2×10-8 mol/L, the Signal-to-Noise Ratio (SNR) S/N=5. The correlation coefficient of the detection system within the range of 1.8 × 10-7 mol/L~ 4 × 10-5mol/L was 0.9972.

  17. Data Mining and Intrusion Detection Systems

    Directory of Open Access Journals (Sweden)

    Zibusiso Dewa

    2016-01-01

    Full Text Available The rapid evolution of technology and the increased connectivity among its components, imposes new cyber-security challenges. To tackle this growing trend in computer attacks and respond threats, industry professionals and academics are joining forces in order to build Intrusion Detection Systems (IDS that combine high accuracy with low complexity and time efficiency. The present article gives an overview of existing Intrusion Detection Systems (IDS along with their main principles. Also this article argues whether data mining and its core feature which is knowledge discovery can help in creating Data mining based IDSs that can achieve higher accuracy to novel types of intrusion and demonstrate more robust behaviour compared to traditional IDSs.

  18. A System for Traffic Violation Detection

    Directory of Open Access Journals (Sweden)

    Nourdine Aliane

    2014-11-01

    Full Text Available This paper describes the framework and components of an experimental platform for an advanced driver assistance system (ADAS aimed at providing drivers with a feedback about traffic violations they have committed during their driving. The system is able to detect some specific traffic violations, record data associated to these faults in a local data-base, and also allow visualization of the spatial and temporal information of these traffic violations in a geographical map using the standard Google Earth tool. The test-bed is mainly composed of two parts: a computer vision subsystem for traffic sign detection and recognition which operates during both day and nighttime, and an event data recorder (EDR for recording data related to some specific traffic violations. The paper covers firstly the description of the hardware architecture and then presents the policies used for handling traffic violations.

  19. A System for Traffic Violation Detection

    Science.gov (United States)

    Aliane, Nourdine; Fernandez, Javier; Mata, Mario; Bemposta, Sergio

    2014-01-01

    This paper describes the framework and components of an experimental platform for an advanced driver assistance system (ADAS) aimed at providing drivers with a feedback about traffic violations they have committed during their driving. The system is able to detect some specific traffic violations, record data associated to these faults in a local data-base, and also allow visualization of the spatial and temporal information of these traffic violations in a geographical map using the standard Google Earth tool. The test-bed is mainly composed of two parts: a computer vision subsystem for traffic sign detection and recognition which operates during both day and nighttime, and an event data recorder (EDR) for recording data related to some specific traffic violations. The paper covers firstly the description of the hardware architecture and then presents the policies used for handling traffic violations. PMID:25421737

  20. Development of a Miniaturized and Portable Methane Analyzer for Natural Gas Leak Walking Surveys

    Science.gov (United States)

    Huang, Y. W.; Leen, J. B.; Gupta, M.; Baer, D. S.

    2016-12-01

    Traditional natural gas leak walking surveys have been conducted with devices that are based on technologies such as flame ionization detector (FID), IR-based spectrometer and IR camera. The sensitivity is typically on the ppm level. The low sensitivity means the device cannot pick up leaks far from it, and more time is spent surveying the area before pinpointing the leak location. A miniaturized methane analyzer has been developed to significantly improve the sensitivity of the device used in walking surveys to detect natural gas leaks at greater distance. ABB/LGR's patented Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS) is utilized to offer rugged and highly sensitive methane detection in a portable package. The miniaturized package weighs 13.5 lb, with a 4-hour rechargeable battery inside. The precision of the analyzer for methane is 2 ppb at 1 second. The analyzer operates at 10 Hz and its flow response time is 3 seconds for measurements through a 1-meter long sampling wand to registering on the data stream. The data can be viewed in real-time on a tablet or a smartphone. The compact and simplified package of the methane analyzer allows for more efficient walking surveys. It also allows for other applications that require low-power, low-weight and a portable package. We present data from walking surveys to demonstrate its ability to detect methane leaks.

  1. CT assessment of anastomotic bowel leak

    Energy Technology Data Exchange (ETDEWEB)

    Power, N. [Department of Radiology, Sunnybrook Hospital, Toronto, Ontario M4N 3M5 (Canada); Atri, M. [Department of Radiology, Sunnybrook Hospital, Toronto, Ontario M4N 3M5 (Canada)]. E-mail: mostafa.atri@sw.ca; Ryan, S. [Department of Radiology, Sunnybrook Hospital, Toronto, Ontario M4N 3M5 (Canada); Haddad, R. [Department of Surgery, Sunnybrook Hospital, Toronto, Ontario M4N 3M5 (Canada); Smith, A. [Department of Surgery, Sunnybrook Hospital, Toronto, Ontario M4N 3M5 (Canada)

    2007-01-15

    Aim: To evaluate the predictors of clinically important gastrointestinal anastomotic leaks using multidetector computed tomography (CT). Subjects and methods: Ninety-nine patients, 73 with clinical suspicion of anastomotic bowel leak and 26 non-bowel surgery controls underwent CT to investigate postoperative sepsis. Fifty patients had undergone large bowel and 23 small bowel anastomoses. The time interval from surgery was 3-30 days (mean 10 {+-} 5.9 SD) for the anastomotic group and 3-40 days (mean 14 {+-} 11 SD) for the control group (p = 0.3). Two radiologists blinded to the final results reviewed the CT examinations in consensus and recorded the presence of peri-anastomotic air, fluid or combination of the two; distant loculated fluid or combination of fluid and air; free air or fluid; and intestinal contrast leak. Final diagnosis of clinically important anastomotic leak (CIAL) was confirmed at surgery or by chart review of predetermined clinical and laboratory criteria. Results: The prevalence of CIAL in the group undergoing CT was 31.5% (23/73). The CT examinations with documented leak were performed 5-28 (mean; 11.4 {+-} 6 SD) days after surgery. Nine patients required repeat operation, 10 percutaneous abscess drainage, two percutaneous drainage followed by surgery, and two prolonged antibiotic treatment and total parenteral nutrition (TPN). Of the CT features examined, only peri-anastomotic loculated fluid containing air was more frequently seen in the CIAL group as opposed to the no leak group (p = 0.04). There was no intestinal contrast leakage in this cohort. Free air was present up to 9 days and loculated air up to 26 days without CIAL. Conclusion: Most postoperative CT features overlap between patients with and without CIAL. The only feature seen statistically more frequently with CIAL is peri-anastomotic loculated fluid containing air.

  2. A Bayesian Networks in Intrusion Detection Systems

    Directory of Open Access Journals (Sweden)

    M. Mehdi

    2007-01-01

    Full Text Available Intrusion detection systems (IDSs have been widely used to overcome security threats in computer networks. Anomaly-based approaches have the advantage of being able to detect previously unknown attacks, but they suffer from the difficulty of building robust models of acceptable behaviour which may result in a large number of false alarms caused by incorrect classification of events in current systems. We propose a new approach of an anomaly Intrusion detection system (IDS. It consists of building a reference behaviour model and the use of a Bayesian classification procedure associated to unsupervised learning algorithm to evaluate the deviation between current and reference behaviour. Continuous re-estimation of model parameters allows for real time operation. The use of recursive Log-likelihood and entropy estimation as a measure for monitoring model degradation related with behavior changes and the associated model update show that the accuracy of the event classification process is significantly improved using our proposed approach for reducing the missing-alarm.

  3. Endoscopic management of a gastric leak after laparoscopic sleeve gastrectomy using the over-the-scope-clip (Ovesco® system

    Directory of Open Access Journals (Sweden)

    Yurena Caballero

    Full Text Available Laparoscopic sleeve gastrectomy is currently used for the management of morbid obesity. Gastric fistula is the primary life-threatening complication, and its resolution continues to be a strong challenge for surgeons. Multiple treatment options are available, ranging from conservative therapy to endoscopic use of clips or stents, and even surgical reoperation involving total gastrectomy or conversion to a different bariatric technique. The applicability of each individual option will depend on the type of fistula and the patient clinical status. A clinical case is reported of a 29-year-old male patient with a body mass index at 49% who following laparoscopic sleeve gastrectomy had a delayed gastric fistula that failed to respond to conservative management but was successfully treated using the over-the-scope clip (Ovesco® system.

  4. Hydraulic analysis of water supply networks and controlling the leak using WATER GEMS model

    Directory of Open Access Journals (Sweden)

    Mahmood Motevalizadeh

    2016-03-01

    Full Text Available Given that the discussion on water is strategic in terms of economic and social aspects as well as environmental impact, water leak in urban water-supply systems is very important, so, dealing with it is necessary and inevitable. Controlling and reducing water leak are of the main goals of water supplier organization due to limitations in terms of water resources, especially in dry lands which have few water resources. Pressure management is an efficient tool to reduce costs, enhance the operation of the network and therefore, it reduces the leak and increases the life of facilities and equipment and reduces the number of accidents. Smart pressure containment is a good way to prevent excess pressure in network to control undesirable phenomenon of leak which is directly related to pressure. In this study, Badamuiyeh water supply complex in Kerman City was selected to study on adjusting the pressure to control the leak of water and the hydraulic analysis was performed with demand-based method (DDSM, which is common technique and demand is constant, by Water GEMS software. For this end, the pressure reducing valves (prv were installed in critical point and they were timed to provide standard pressure in all nodes of the network and then, the impact of smart pressure management on water supply system has been investigated. Then its impact on the leak was examined and the results show that smart pressure control through pressure-reducing valve is a proper method for optimal management of water and reducing the leak significantly that with 45.15% reduction in average pressure, one can reduce the leak as much as 25.67% that as its result, 15380 m3 of water is annually saved in this region which is equal to 27.18% of consuming water.

  5. Single-Shell Tank Leak Integrity Summary

    Energy Technology Data Exchange (ETDEWEB)

    Harlow, D. G. [Washington River Protection Solutions LLC, Richland, WA (United States); Girardot, C. L. [Washington River Protection Solutions LLC, Richland, WA (United States); Venetz, T. J. [Washington River Protection Solutions LLC, Richland, WA (United States)

    2015-03-26

    This document summarizes and evaluates the information in the Hanford Tri-Party Agreement Interim Milestone M-045-91F Targets completed between 2010 and 2015. 1) Common factors of SST liner failures (M-045-91F-T02), 2) the feasibility of testing for ionic conductivity between the inside and outside of SSTs (M-045-91F-T03, and 3) the causes, locations, and rates of leaks from leaking SSTs (M-045-91F-T04).

  6. Automating Vendor Fraud Detection in Enterprise Systems

    Directory of Open Access Journals (Sweden)

    Kishore Singh

    2013-06-01

    Full Text Available Fraud is a multi-billion dollar industry that continues to grow annually. Many organisations are poorly prepared to prevent and detect fraud. Fraud detection strategies are intended to quickly and efficiently identify fraudulent activities that circumvent preventative measures. In this paper we adopt a Design-Science methodological framework to develop a model for detection of vendor fraud based on analysis of patterns or signatures identified in enterprise system audit trails. The concept is demonstrated be developing prototype software. Verification of the prototype is achieved by performing a series of experiments. Validation is achieved by independent reviews from auditing practitioners. Key findings of this study are: i automating routine data analytics improves auditor productivity and reduces time taken to identify potential fraud, and ii visualisations assist in promptly identifying potentially fraudulent user activities. The study makes the following contributions: i a model for proactive fraud detection, ii methods for visualising user activities in transaction data, iii a stand-alone MCL-based prototype.

  7. Visible-light system for detecting doxorubicin contamination on skin and surfaces.

    Science.gov (United States)

    Van Raalte, J; Rice, C; Moss, C E

    1990-05-01

    A portable system that uses fluorescence stimulated by visible light to identify doxorubicin contamination on skin and surfaces was studied. When activated by violet-blue light in the 465-nm range, doxorubicin fluoresces, emitting orange-red light in the 580-nm range. The light source to stimulate fluorescence was a slide projector with a filter to selectively pass short-wave (blue) visible light. Fluorescence was both observed visually with viewing spectacles and photographed. Solutions of doxorubicin in sterile 0.9% sodium chloride injection were prepared in nine standard concentrations ranging from 2 to 0.001 mg/mL. Droplets of each admixture were placed on stainless steel, laboratory coat cloth, pieces of latex examination glove, bench-top absorbent padding, and other materials on which antineoplastics might spill or leak. These materials then were stored for up to eight weeks and photographed weekly. The relative ability of water, household bleach, hydrogen peroxide solution, and soap solution to deactivate doxorubicin was also measured. Finally, this system was used to inspect the antineoplastic-drug preparation and administration areas of three outpatient cancer clinics for doxorubicin contamination. Doxorubicin fluorescence was easily detectable with viewing spectacles when a slide projector was used as the light source. The photographic method was sensitive for doxorubicin concentrations from 2.0 to 0.001 mg/mL. Immersion of study materials in bleach for one minute eliminated detectable fluorescence. Doxorubicin contamination is detectable for at least eight weeks in the ambient environment. Probable doxorubicin contamination was detected in two of the three clinics surveyed. A safe, portable system that uses fluorescence stimulated by visible light is a sensitive method for detecting doxorubicin on skin and surfaces.

  8. 基于物联网技术的石化厂区有毒气体泄漏在线监测系统%Online Monitoring System of Toxic Gas Leak for Petrochemical Plant Based on Internet of Things

    Institute of Scientific and Technical Information of China (English)

    张锋; 李凯亮; 曾俊林

    2015-01-01

    According to the production safety problems caused by toxic gas leak,which may occur in the productive process of petrochemical plants,an online monitoring system of toxic gas leak for petrochemical plant was designed ,which was a combination of wireless sensor networks,portable devices,cloud instant storage function,real-time display web pages,online monitoring SMS a-larm,android mobile real-time display and solar charging technology.The functions of real-time,online monitoring and early warning for the toxic gases ( mainly including H2 S,SO2 ,CO,CH4 ) ,temperature,humidity,wind direction,wind speed,PM2.5 and other fac-tors in petrochemical plant were realized,and made the production supervisors grasp the toxic gases’ real-time dynamic information of petrochemical factory,thus removing the factors that lead to dangerous accidents immediately and controlling the risk in the ini-tial stage,so as to realize the safe,sustainable and efficient chemical production.Experiments show that the on-line monitoring sys-tem has good reliability,security and practicability.%针对石化厂在生产过程中可能发生有毒气体泄漏带来的生产安全问题,设计了一套石化厂区有毒气体泄漏在线监测系统,该系统集无线传感器网络、便携式设备、云端即时存储功能、网页实时显示、在线监测短信报警、安卓手机实时显示及太阳能充电等技术于一体,实现对石化厂区中有毒气体(主要包括H2 S、SO2、CO、CH4)、温度、湿度、风向、风速、PM2.5等因子的实时、在线监测和预警,使生产管理人员掌握石化厂区的有毒气体实时动态信息,对可能引发危险事故的因素及时排除,把危险控制在始发阶段,以实现化工生产的安全、持续、高效进行。实验表明:该在线监测系统具有良好可靠性、安全性和实用性。

  9. The ITER Radial Neutron Camera Detection System

    Science.gov (United States)

    Marocco, D.; Belli, F.; Bonheure, G.; Esposito, B.; Kaschuck, Y.; Petrizzi, L.; Riva, M.

    2008-03-01

    A multichannel neutron detection system (Radial Neutron Camera, RNC) will be installed on the ITER equatorial port plug 1 for total neutron source strength, neutron emissivity/ion temperature profiles and nt/nd ratio measurements [1]. The system is composed by two fan shaped collimating structures: an ex-vessel structure, looking at the plasma core, containing tree sets of 12 collimators (each set lying on a different toroidal plane), and an in-vessel structure, containing 9 collimators, for plasma edge coverage. The RNC detecting system will work in a harsh environment (neutron fiux up to 108-109 n/cm2 s, magnetic field >0.5 T or in-vessel detectors), should provide both counting and spectrometric information and should be flexible enough to cover the high neutron flux dynamic range expected during the different ITER operation phases. ENEA has been involved in several activities related to RNC design and optimization [2,3]. In the present paper the up-to-date design and the neutron emissivity reconstruction capabilities of the RNC will be described. Different options for detectors suitable for spectrometry and counting (e.g. scintillators and diamonds) focusing on the implications in terms of overall RNC performance will be discussed. The increase of the RNC capabilities offered by the use of new digital data acquisition systems will be also addressed.

  10. Intrusion Detection Systems Based On Packet Sniffing

    Directory of Open Access Journals (Sweden)

    Ushus Maria Joseph

    2013-01-01

    Full Text Available In the present era of networks, security of network systems is becoming increasingly important, as more and more sensitive information is being stored and manipulated online. The paper entitled ’Packet Sniffing’ is a IDS where it monitors packets on the network wire and attempts to the discovery of hacker/cracker who is attempting to break into system. Packet Sniffing also finds the contents and tracks the data packet in the network system. This sniffing is being performed by comparing the captured packet with the intruder details stored in the database .If the packet is found to be an intruder it is then forwarded to the firewall with the respective message for blocking. The Emotional Ants module contains the sender and receiver .The sender will inform all the other Ants running in other machines about the detection of intruder through his pheromone (Messages. The receiver in Ants will listen for the messages from other Ants

  11. Experience with helium leak and thermal shocks test of SST-1 cryo components

    Science.gov (United States)

    Sharma, Rajiv; Nimavat, Hiren; Srikanth, G. L. N.; Bairagi, Nitin; Shah, Pankil; Tanna, V. L.; Pradhan, S.

    2012-11-01

    A steady state superconducting Tokamak SST-1 is presently under its assembly stage at the Institute for Plasma Research. The SST-1 machine is a family of Superconducting SC coils for both Toroidal field and Poloidal Field. An ultra high vacuum compatible vacuum vessel, placed in the bore of the TF coils, houses the plasma facing components. A high vacuum cryostat encloses all the SC coils and the vacuum vessel. Liquid Nitrogen (LN2) cooled thermal shield between the vacuum vessel & SC coils as well as between cryostat and the SC coils. There are number of crucial cryogenic components as Electrical isolators, 80 K thermal shield, Cryogenic flexible hose etc., which have to be passed the performance validation tests as part of fulfillment of the stringent QA/QC before incorporated in the main assembly. The individual leak tests of components at RT as well as after thermal cycle from 300 K to 77 K ensure us to make final overall leak proof system. These components include, Large numbers of Electrical Isolators for Helium as well as LN2 services, Flexible Bellows and Hoses for Helium as well as LN2 services, Thermal shock tests of large numbers of 80 K Bubble shields In order to validate the helium leak tightness of these components, we have used the calibrated mass spectrometer leak detector (MSLD) at 300 K, 77 K and 4.2. Since it is very difficult to locate the leaks, which are appearing at rather lower temperatures e.g. less than 20 K, We have invented different approaches to resolve the issue of such leaks. This paper, in general describes the design of cryogenic flexible hose, assembly, couplings for leak testing, test method and techniques of thermal cycles test at 77 K inflow conditions and leak testing aspects of different cryogenic components. The test results, the problems encountered and its solutions techniques are discussed.

  12. Risk factors for postoperative cerebrospinal fluid leak and meningitis after expanded endoscopic endonasal surgery.

    Science.gov (United States)

    Ivan, Michael E; Iorgulescu, J Bryan; El-Sayed, Ivan; McDermott, Michael W; Parsa, Andrew T; Pletcher, Steven D; Jahangiri, Arman; Wagner, Jeffrey; Aghi, Manish K

    2015-01-01

    Postoperative cerebrospinal fluid (CSF) leak is a serious complication of transsphenoidal surgery, which can lead to meningitis and often requires reparative surgery. We sought to identify preoperative risk factors for CSF leaks and meningitis. We reviewed 98 consecutive expanded endoscopic endonasal surgeries performed from 2008-2012 and analyzed preoperative comorbidities, intraoperative techniques, and postoperative care. Univariate and multivariate analyses were performed. The most common pathologies addressed included pituitary adenoma, Rathke cyst, chordoma, esthesioneuroblastoma, meningioma, nasopharyngeal carcinoma, and squamous cell carcinoma. There were 11 CSF leaks (11%) and 10 central nervous system (CNS) infections (10%). Univariate and multivariate analysis of preoperative risk factors showed that patients with non-ideal body mass index (BMI) were associated with higher rate of postoperative CSF leak and meningitis (both p<0.01). Also, patients with increasing age were associated with increased CSF leak (p = 0.03) and the length of time a lumbar drain was used postoperatively was associated with infection in a univariate analysis. In addition, three of three endoscopic transsphenoidal surgeries combined with open cranial surgery had a postoperative CSF leak and CNS infection rate which was a considerably higher rate than for transsphenoidal surgeries alone or surgeries staged with open cases (p<0.01 and p=0.04, respectively) In this series of expanded endoscopic transsphenoidal surgeries, preoperative BMI remains the most important preoperative predictor for CSF leak and infection. Other risk factors include age, intraoperative CSF leak, lumbar drain duration, and cranial combined cases. Risks associated with complex surgical resections when combining open and endoscopic approaches could be minimized by staging these procedures.

  13. Arc burst pattern analysis fault detection system

    Science.gov (United States)

    Russell, B. Don (Inventor); Aucoin, B. Michael (Inventor); Benner, Carl L. (Inventor)

    1997-01-01

    A method and apparatus are provided for detecting an arcing fault on a power line carrying a load current. Parameters indicative of power flow and possible fault events on the line, such as voltage and load current, are monitored and analyzed for an arc burst pattern exhibited by arcing faults in a power system. These arcing faults are detected by identifying bursts of each half-cycle of the fundamental current. Bursts occurring at or near a voltage peak indicate arcing on that phase. Once a faulted phase line is identified, a comparison of the current and voltage reveals whether the fault is located in a downstream direction of power flow toward customers, or upstream toward a generation station. If the fault is located downstream, the line is de-energized, and if located upstream, the line may remain energized to prevent unnecessary power outages.

  14. A Survey on VANET Intrusion Detection Systems

    Directory of Open Access Journals (Sweden)

    Mohammed ERRITALI

    2013-04-01

    Full Text Available In recent years, the security issues on Vehicular ad hoc networks (VANETs have become one of the primary concerns. The VANET is inherently very vulnerable to attacks than wired network because it is characterized by high mobility, shared wireless medium and the absence of centralized security services offered by dedicated equipment such as firewalls and authentication servers. Attackcountermeasures such as digital signature and encryption, can be used as the first line of defense for reducing the possibilities of attacks. However, these techniques have limited prevention in general, and they are designed for a set of known attacks. They are unlikely to avoid most recent attacks that are designed to circumvent existing security measures. For this reason, there is a need of second technique to “detect and notify” these newer attacks, i.e. “intrusion detection”. This article aims to present and classifycurrent techniques of Intrusion Detection System (IDS aware VANETs.

  15. Performances of the leak microstructures

    CERN Document Server

    Lombardi, M; Lombardi, F S

    2002-01-01

    The capabilities of a new microstructure, anode point based, for the detection of gas ionizing radiations are stressed. For every single detected ionizing radiation it gives a pair of 'induced' charges (anodic and cathodic) of the same amount (pulses of the same amplitudes), of opposite sign, with the same collection time and essentially in time coincidence, that are proportional to the primary ionization collected. The complete lack of insulating materials in the active volume of this microstructure avoids problems of charging-up and makes stable and repeatable its behaviour. Primary avalanches with a size of more than 2.5x10 sup 7 electrons (4 pC) giving current pulses with a peak of more than 0.26 mA on 100 OMEGA and about 30 ns duration are possible with 5.9 keV X-rays of sup 5 sup 5 Fe working in proportional region and in isobutane gas. Single electrons emitted by a heated filament (E sub c <1 eV) were detected in 760 Torr of isobutane; with an estimated gas gain of 1.2x10 sup 6 a counting rate up to...

  16. Endoscopic diagnosis and treatment of biliar y leak in patients following liver transplantation:a prospective clinical study

    Institute of Scientific and Technical Information of China (English)

    Jia-Zhi Liao; Qiu Zhao; Hua Qin; Rong-Xiang Li; Wei Hou; Pei-Yuan Li; Nan-Zhi Liu; De-Ming Li

    2007-01-01

    BACKGROUND:Orthotopic liver transplantation has been widely used in patients with end-stage liver disease within the last two decades. However, the prevalence of biliary complications after liver transplantation remains high. The most common short-term biliary complication may be biliary leak. So, we examined 13 patients with biliary leak after liver transplantation, attempting to evaluate the role of endoscopic diagnosis and treatment of biliary leak and the incidence of bile duct stricture after healing of the leak. METHODS: Six cases of T-tube leak and seven cases of anastomosis leak complicating liver transplantation were enrolled in this prospective study. Six patients were treated by endoscopic plastic stent placement, two by nasobiliary catheter drainage, two by papillosphincterotomy, and three by nasobiliary catheter drainage combined with plastic stent placement. Some patients received growth hormone treatment. RESULTS: The bile leak resolution time was 10-35 days in 10 patients with complete documentation. The median time of leak resolution was 15.3 days. Four cases of anastomosis stricture, three cases of common hepatic duct and one case of multiple bile duct stenosis were detected by follow-up nasobiliary catheter cholangiography or endoscopic retrograde cholangiopancreatography. CONCLUSIONS:Endoscopic nasobiliary catheter or plastic stent placement is a safe and effective treatment for bile duct stricture occurring after bile leak resolution in most liver transplantation patients. Nasobiliary catheter combined with plastic stent placement may be the best choice for treating bile leak, because, theoretically, it may prevent the serious condition resulting from accidental nasobiliary catheter dislocation, and it may have prophylactic effects on upcoming bile duct stricture, although this should be further conifrmed.

  17. Intelligent Flamefinder Detection and Alert System (IFDAS) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Current hydrogen flame detection systems exhibit shortcomings ranging from limited detection range, to localization inaccuracy, limited sensitivity, false alarms,...

  18. Development of the environmental neutron detection system

    CERN Document Server

    Kume, K

    2003-01-01

    Environmental neutron detection system is proposed. The main goal of this system was set to detect fast and thermal neutrons with the identical detector setup without degraders. A detector setup for the system with a sup 1 sup 0 B doped liquid scintillator, which had been optimized for thermal neutron counting in last year, was developed first. For optimization of for fast neutron counting, density of sup 1 sup 0 B and the size of the detector were fixed by measurement of fast neutrons, with help of the Monte Carlo calculation. In the meantime, possibility of the use of inorganic scintillators in neutron counting were verified, to solve the problem occurring at the long term use of the organic liquid scintillators. The detectors checked were LSO, BaF sub 2 , BGO and GSO. LSO and BaF sub 2 have much more difficulties in neutron counting such as background counting rates and BGO has some unclear signals at neutron measurements. GSO was shown to be the most probable candidate among them at the measurement of neu...

  19. Development of Exhaust Leak Detector Device for Automotive Service Industry: A Prototype Design

    Directory of Open Access Journals (Sweden)

    Eida Nadirah Roslin

    2016-08-01

    Full Text Available The exhaust system plays a vital role in removing the gaseous emissions that is being produced within the combustion chamber during fuel-air mixture activities. The exhaust system is defined as a series of chambers and pipes that starts at the engine and ends at the back of the car with the tail pipe. However if there are any leaks in the exhaust system, it provide a direct path for the emission gaseous including carbon monoxide to enter can be very dangerous as it provides a direct path for carbon monoxide and other dangerous gaseous emissions to enter the cowl vent at the base of the windshield and directly to the passenger compartment. The risk of exposure to these hazardous gaseous is also high especially during vehicle maintenance services in suspected cases of leakages to the exhaust system.  The inspection of the exhaust system is done manually in most of the automotive services workshops. In this paper, accidental risks of performing these inspection jobs on a vehicle’s exhaust system, performed by a technician are discussed. In order to minimize the risks to technicians or mechanics, a prototype device to detect exhaust leakage was developed using a gas sensor module and a web camera. This device was successfully operated in detecting possible leakages of the exhaust system.

  20. Optical-Fiber Leak Detector

    Science.gov (United States)

    Workman, Gary L.; Kosten, Susan E.

    1994-01-01

    Proposed optical-fiber sensor detects small changes in pressure in elastomeric O-ring or similar pressure seal, which may indicate deterioration of seal and interpreted as indications of incipient failure. According to concept, length of optical fiber embedded in seal. Light-emitting diode illuminates one end of fiber; photodetector measures intensity of light emerging from other end. Pressure-induced changes in seal bend fiber slightly, altering microbending-induced loss of light from fiber and alter intensity of light at photodetector. Change in intensity approximately proportional to change in pressure.

  1. LMFBR steam generator systems development program progress report

    Energy Technology Data Exchange (ETDEWEB)

    None

    The intent of this program is to investigate methods of producing 2-1/4 Cr-1Mo duplex tubing to meet the structural, thermal/hydraulic and leak detection design requirements of the duplex tube leak detection concept for application on the Demonstration Plant and/or prototype steam generator. The leak detection concept as envisioned for LMFBR steam generator application will be analyzed regarding response to credible leak situations. The results of testing will be used for this analysis. The third fluid system will be conceptually designed including the two plena design adaptations being considered and the advantages and disadvantages of each will be assessed. The test program for the single-tube steam generator model will be developed in accordance with the technical and schedular objectives of the LMFBR duplex tube steam generator development program. A conceptual steam generator configuration will be established for use as a reference in the on-going feasibility studies and Demo Plant system development.

  2. Experiences with leak rate calculations methods for LBB application

    Energy Technology Data Exchange (ETDEWEB)

    Grebner, H.; Kastner, W.; Hoefler, A.; Maussner, G. [and others

    1997-04-01

    In this paper, three leak rate computer programs for the application of leak before break analysis are described and compared. The programs are compared to each other and to results of an HDR Reactor experiment and two real crack cases. The programs analyzed are PIPELEAK, FLORA, and PICEP. Generally, the different leak rate models are in agreement. To obtain reasonable agreement between measured and calculated leak rates, it was necessary to also use data from detailed crack investigations.

  3. Method and system for detecting explosives

    Science.gov (United States)

    Reber, Edward L [Idaho Falls, ID; Jewell, James K [Idaho Falls, ID; Rohde, Kenneth W [Idaho Falls, ID; Seabury, Edward H [Idaho Falls, ID; Blackwood, Larry G [Idaho Falls, ID; Edwards, Andrew J [Idaho Falls, ID; Derr, Kurt W [Idaho Falls, ID

    2009-03-10

    A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.

  4. A complete low cost radon detection system.

    Science.gov (United States)

    Bayrak, A; Barlas, E; Emirhan, E; Kutlu, Ç; Ozben, C S

    2013-08-01

    Monitoring the (222)Rn activity through the 1200 km long Northern Anatolian fault line, for the purpose of earthquake precursory, requires large number of cost effective radon detectors. We have designed, produced and successfully tested a low cost radon detection system (a radon monitor). In the detector circuit of this monitor, First Sensor PS100-7-CER-2 windowless PIN photodiode and a custom made transempedence/shaping amplifier were used. In order to collect the naturally ionized radon progeny to the surface of the PIN photodiode, a potential of 3500 V was applied between the conductive hemi-spherical shell and the PIN photodiode. In addition to the count rate of the radon progeny, absolute pressure, humidity and temperature were logged during the measurements. A GSM modem was integrated to the system for transferring the measurements from the remote locations to the data process center.

  5. System for Anomaly and Failure Detection (SAFD) system development

    Science.gov (United States)

    Oreilly, D.

    1992-07-01

    This task specified developing the hardware and software necessary to implement the System for Anomaly and Failure Detection (SAFD) algorithm, developed under Technology Test Bed (TTB) Task 21, on the TTB engine stand. This effort involved building two units; one unit to be installed in the Block II Space Shuttle Main Engine (SSME) Hardware Simulation Lab (HSL) at Marshall Space Flight Center (MSFC), and one unit to be installed at the TTB engine stand. Rocketdyne personnel from the HSL performed the task. The SAFD algorithm was developed as an improvement over the current redline system used in the Space Shuttle Main Engine Controller (SSMEC). Simulation tests and execution against previous hot fire tests demonstrated that the SAFD algorithm can detect engine failure as much as tens of seconds before the redline system recognized the failure. Although the current algorithm only operates during steady state conditions (engine not throttling), work is underway to expand the algorithm to work during transient condition.

  6. 46 CFR 108.405 - Fire detection system.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fire detection system. 108.405 Section 108.405 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.405 Fire detection system. (a) Each fire detection system...

  7. Characterizing and Improving Distributed Intrusion Detection Systems.

    Energy Technology Data Exchange (ETDEWEB)

    Hurd, Steven A; Proebstel, Elliot P.

    2007-11-01

    Due to ever-increasing quantities of information traversing networks, network administrators are developing greater reliance upon statistically sampled packet information as the source for their intrusion detection systems (IDS). Our research is aimed at understanding IDS performance when statistical packet sampling is used. Using the Snort IDS and a variety of data sets, we compared IDS results when an entire data set is used to the results when a statistically sampled subset of the data set is used. Generally speaking, IDS performance with statistically sampled information was shown to drop considerably even under fairly high sampling rates (such as 1:5). Characterizing and Improving Distributed Intrusion Detection Systems4AcknowledgementsThe authors wish to extend our gratitude to Matt Bishop and Chen-Nee Chuah of UC Davis for their guidance and support on this work. Our thanks are also extended to Jianning Mai of UC Davis and Tao Ye of Sprint Advanced Technology Labs for their generous assistance.We would also like to acknowledge our dataset sources, CRAWDAD and CAIDA, without which this work would not have been possible. Support for OC48 data collection is provided by DARPA, NSF, DHS, Cisco and CAIDA members.

  8. 49 CFR 230.64 - Leaks under lagging.

    Science.gov (United States)

    2010-10-01

    ..., DEPARTMENT OF TRANSPORTATION STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS Boilers and Appurtenances Steam Leaks § 230.64 Leaks under lagging. The steam locomotive owner and/or operator shall take out of service at once any boiler that has developed a leak under the lagging due to a crack in the shell, or...

  9. Double Shell Tank AY-102 Radioactive Waste Leak Investigation

    Energy Technology Data Exchange (ETDEWEB)

    Washenfelder, Dennis J.

    2014-04-10

    PowerPoint. The objectives of this presentation are to: Describe Effort to Determine Whether Tank AY-102 Leaked; Review Probable Causes of the Tank AY-102 Leak; and, Discuss Influence of Leak on Hanford’s Double-Shell Tank Integrity Program.

  10. Effect of heat leaks in platinum resistance thermometry.

    Science.gov (United States)

    Goldratt, E; Yeshurun, Y; Greenfield, A J

    1980-03-01

    The effect of heat leaks in platinum resistance thermometry is analyzed. An experimental method is proposed for estimating the magnitude of this effect. Results are reported for the measurement of the temperature of a hot, solid body under different heat-leak configurations. Design criteria for thermometers are presented which minimize the effect of such heat leaks.

  11. An overview to Software Architecture in Intrusion Detection System

    CERN Document Server

    Bahrami, Mehdi

    2012-01-01

    Network intrusion detection systems provide proactive defense against security threats by detecting and blocking attack-related traffic. This task can be highly complex, and therefore, software based network intrusion detection systems have difficulty in handling high speed links. This paper reviews of many type of software architecture in intrusion detection systems and describes the design and implementation of a high-performance network intrusion detection system that combines the use of software-based network intrusion detection sensors and a network processor board. The network processor acts as a customized load balancing splitter that cooperates with a set of modified content-based network intrusion detection sensors in processing network traffic.

  12. Detective quantum efficiency of the LODOX system

    Science.gov (United States)

    de Villiers, Mattieu; de Jager, Gerhard

    2003-06-01

    The Detective Quantum Efficiency (DQE) of a digital x-ray imaging system describes how much of the signal to noise ratio of the incident radiation is sustained in the resultant digital image. This measure of dose efficiency is suitable for the comparison of detectors produced by different manufacturers. The International Electrotechnical Commission (IEC) stipulates standard methods and conditions for the measurement of the DQE for single exposure imaging systems such as flat panel detectors. This paper shows how the calculation is adapted for DQE measurements of scanning systems. In this paper it is described how to measure the presampled Modulation Transfer Function (MTF) using an edge test method and how to extract the horizontal and vertical components of the Noise Power Spectrum (NPS) in a way that is insensitive to structured noise patterns often found in scanned images. The calculation of the total number of incident photons from the radiation dose measurement is explained and results are provided for the Lodox low dose full body digital x-ray scanning system which is developed in South Africa.

  13. LAN attack detection using Discrete Event Systems.

    Science.gov (United States)

    Hubballi, Neminath; Biswas, Santosh; Roopa, S; Ratti, Ritesh; Nandi, Sukumar

    2011-01-01

    Address Resolution Protocol (ARP) is used for determining the link layer or Medium Access Control (MAC) address of a network host, given its Internet Layer (IP) or Network Layer address. ARP is a stateless protocol and any IP-MAC pairing sent by a host is accepted without verification. This weakness in the ARP may be exploited by malicious hosts in a Local Area Network (LAN) by spoofing IP-MAC pairs. Several schemes have been proposed in the literature to circumvent these attacks; however, these techniques either make IP-MAC pairing static, modify the existing ARP, patch operating systems of all the hosts etc. In this paper we propose a Discrete Event System (DES) approach for Intrusion Detection System (IDS) for LAN specific attacks which do not require any extra constraint like static IP-MAC, changing the ARP etc. A DES model is built for the LAN under both a normal and compromised (i.e., spoofed request/response) situation based on the sequences of ARP related packets. Sequences of ARP events in normal and spoofed scenarios are similar thereby rendering the same DES models for both the cases. To create different ARP events under normal and spoofed conditions the proposed technique uses active ARP probing. However, this probing adds extra ARP traffic in the LAN. Following that a DES detector is built to determine from observed ARP related events, whether the LAN is operating under a normal or compromised situation. The scheme also minimizes extra ARP traffic by probing the source IP-MAC pair of only those ARP packets which are yet to be determined as genuine/spoofed by the detector. Also, spoofed IP-MAC pairs determined by the detector are stored in tables to detect other LAN attacks triggered by spoofing namely, man-in-the-middle (MiTM), denial of service etc. The scheme is successfully validated in a test bed.

  14. Advanced leak location-research evaluation demonstration (ALL-RED) project

    Science.gov (United States)

    Hammaker, Robert G.; Colsher, Richard J.

    1994-03-01

    The ALL-RED Project was developed to evaluate the use of IR thermography in three specific new areas: condenser air-in leakage; condenser tube leaks; and boiler casing leaks. These areas have plagued the utility industry by causing unscheduled downtime, increasing maintenance costs, and creating performance difficulties. Developing techniques that include: establishing specific methods of detection for each application; preparing guidelines for a program structure, technical approach, and cost benefit; as well as organizing a training program, will further enhance the use of this versatile technology and help utilities reduce down time and maintenance costs through condition monitoring using advanced IR Thermography techniques.

  15. Autonomous system for pathogen detection and identification

    Energy Technology Data Exchange (ETDEWEB)

    Belgrader, P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Benett, W. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Bergman, W. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Langlois, R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Mariella, R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Milanovich, F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Miles, R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Venkateswaran, K. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Long, G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Nelson, W. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    1998-09-24

    This purpose of this project is to build a prototype instrument that will, running unattended, detect, identify, and quantify BW agents. In order to accomplish this, we have chosen to start with the world' s leading, proven, assays for pathogens: surface-molecular recognition assays, such as antibody-based assays, implemented on a high-performance, identification (ID)-capable flow cytometer, and the polymerase chain reaction (PCR) for nucleic-acid based assays. With these assays, we must integrate the capability to: l collect samples from aerosols, water, or surfaces; l perform sample preparation prior to the assays; l incubate the prepared samples, if necessary, for a period of time; l transport the prepared, incubated samples to the assays; l perform the assays; l interpret and report the results of the assays. Issues such as reliability, sensitivity and accuracy, quantity of consumables, maintenance schedule, etc. must be addressed satisfactorily to the end user. The highest possible sensitivity and specificity of the assay must be combined with no false alarms. Today, we have assays that can, in under 30 minutes, detect and identify simulants for BW agents at concentrations of a few hundred colony-forming units per ml of solution. If the bio-aerosol sampler of this system collects 1000 Ymin and concentrates the respirable particles into 1 ml of solution with 70% processing efficiency over a period of 5 minutes, then this translates to a detection/ID capability of under 0.1 agent-containing particle/liter of air.

  16. Automatic system for detecting pornographic images

    Science.gov (United States)

    Ho, Kevin I. C.; Chen, Tung-Shou; Ho, Jun-Der

    2002-09-01

    Due to the dramatic growth of network and multimedia technology, people can more easily get variant information by using Internet. Unfortunately, it also makes the diffusion of illegal and harmful content much easier. So, it becomes an important topic for the Internet society to protect and safeguard Internet users from these content that may be encountered while surfing on the Net, especially children. Among these content, porno graphs cause more serious harm. Therefore, in this study, we propose an automatic system to detect still colour porno graphs. Starting from this result, we plan to develop an automatic system to search porno graphs or to filter porno graphs. Almost all the porno graphs possess one common characteristic that is the ratio of the size of skin region and non-skin region is high. Based on this characteristic, our system first converts the colour space from RGB colour space to HSV colour space so as to segment all the possible skin-colour regions from scene background. We also apply the texture analysis on the selected skin-colour regions to separate the skin regions from non-skin regions. Then, we try to group the adjacent pixels located in skin regions. If the ratio is over a given threshold, we can tell if the given image is a possible porno graph. Based on our experiment, less than 10% of non-porno graphs are classified as pornography, and over 80% of the most harmful porno graphs are classified correctly.

  17. Liquid chromatography detection unit, system, and method

    Energy Technology Data Exchange (ETDEWEB)

    Derenzo, Stephen E.; Moses, William W.

    2015-10-27

    An embodiment of a liquid chromatography detection unit includes a fluid channel and a radiation detector. The radiation detector is operable to image a distribution of a radiolabeled compound as the distribution travels along the fluid channel. An embodiment of a liquid chromatography system includes an injector, a separation column, and a radiation detector. The injector is operable to inject a sample that includes a radiolabeled compound into a solvent stream. The position sensitive radiation detector is operable to image a distribution of the radiolabeled compound as the distribution travels along a fluid channel. An embodiment of a method of liquid chromatography includes injecting a sample that comprises radiolabeled compounds into a solvent. The radiolabeled compounds are then separated. A position sensitive radiation detector is employed to image distributions of the radiolabeled compounds as the radiolabeled compounds travel along a fluid channel.

  18. Liquid chromatography detection unit, system, and method

    Science.gov (United States)

    Derenzo, Stephen E.; Moses, William W.

    2015-10-27

    An embodiment of a liquid chromatography detection unit includes a fluid channel and a radiation detector. The radiation detector is operable to image a distribution of a radiolabeled compound as the distribution travels along the fluid channel. An embodiment of a liquid chromatography system includes an injector, a separation column, and a radiation detector. The injector is operable to inject a sample that includes a radiolabeled compound into a solvent stream. The position sensitive radiation detector is operable to image a distribution of the radiolabeled compound as the distribution travels along a fluid channel. An embodiment of a method of liquid chromatography includes injecting a sample that comprises radiolabeled compounds into a solvent. The radiolabeled compounds are then separated. A position sensitive radiation detector is employed to image distributions of the radiolabeled compounds as the radiolabeled compounds travel along a fluid channel.

  19. Introduction To Intrusion Detection System Review

    Directory of Open Access Journals (Sweden)

    Rajni Tewatia

    2015-05-01

    Full Text Available Abstract Security of a network is always an important issue. With the continuously growing network the basic security such as firewall virus scanner is easily deceived by modern attackers who are experts in using software vulnerabilities to achieve their goals. For preventing such attacks we need even smarter security mechanism which act proactively and intelligently. Intrusion Detection System is the solution of such requirement. Many techniques have been used to implement IDS. These technique basically used in the detector part of IDS such as Neural Network Clustering Pattern Matching Rule Based Fuzzy Logic Genetic Algorithms and many more. To improve the performance of an IDS these approaches may be used in combination to build a hybrid IDS so that benefits of two o more approaches may be combined.

  20. Mass Spectrometric Calibration of Controlled Fluoroform Leak Rate Devices Technique and Uncertainty Analysis

    CERN Document Server

    Balsley, S D; Laduca, C A

    2003-01-01

    Controlled leak rate devices of fluoroform on the order of 10 sup - sup 8 atm centre dot cc sec sup - sup 1 at 25 C are used to calibrate QC-1 War Reserve neutron tube exhaust stations for leak detection sensitivity. Close-out calibration of these tritium-contaminated devices is provided by the Gas Dynamics and Mass Spectrometry Laboratory, Organization 14406, which is a tritium analytical facility. The mass spectrometric technique used for the measurement is discussed, as is the first principals calculation (pressure, volume, temperature and time). The uncertainty of the measurement is largely driven by contributing factors in the determination of P, V and T. The expanded uncertainty of the leak rate measurement is shown to be 4.42%, with a coverage factor of 3 (k=3).